WorldWideScience

Sample records for total body rotation

  1. SU-E-T-540: Volumetric Modulated Total Body Irradiation Using a Rotational Lazy Susan-Like Immobilization System

    International Nuclear Information System (INIS)

    Gu, X; Hrycushko, B; Lee, H; Lamphier, R; Jiang, S; Abdulrahman, R; Timmerman, R

    2014-01-01

    Purpose: Traditional extended SSD total body irradiation (TBI) techniques can be problematic in terms of patient comfort and/or dose uniformity. This work aims to develop a comfortable TBI technique that achieves a uniform dose distribution to the total body while reducing the dose to organs at risk for complications. Methods: To maximize patient comfort, a lazy Susan-like couch top immobilization system which rotates about a pivot point was developed. During CT simulation, a patient is immobilized by a Vac-Lok bag within the body frame. The patient is scanned head-first and then feet-first following 180° rotation of the frame. The two scans are imported into the Pinnacle treatment planning system and concatenated to give a full-body CT dataset. Treatment planning matches multiple isocenter volumetric modulated arc (VMAT) fields of the upper body and multiple isocenter parallel-opposed fields of the lower body. VMAT fields of the torso are optimized to satisfy lung dose constraints while achieving a therapeutic dose to the torso. The multiple isocenter VMAT fields are delivered with an indexed couch, followed by body frame rotation about the pivot point to treat the lower body isocenters. The treatment workflow was simulated with a Rando phantom, and the plan was mapped to a solid water slab phantom for point- and film-dose measurements at multiple locations. Results: The treatment plan of 12Gy over 8 fractions achieved 80.2% coverage of the total body volume within ±10% of the prescription dose. The mean lung dose was 8.1 Gy. All ion chamber measurements were within ±1.7% compared to the calculated point doses. All relative film dosimetry showed at least a 98.0% gamma passing rate using a 3mm/3% passing criteria. Conclusion: The proposed patient comfort-oriented TBI technique provides for a uniform dose distribution within the total body while reducing the dose to the lungs

  2. Total body irradiation

    International Nuclear Information System (INIS)

    Novack, D.H.; Kiley, J.P.

    1987-01-01

    The multitude of papers and conferences in recent years on the use of very large megavoltage radiation fields indicates an increased interest in total body, hemibody, and total nodal radiotherapy for various clinical situations. These include high dose total body irradiation (TBI) to destroy the bone marrow and leukemic cells and provide immunosuppression prior to a bone marrow transplant, high dose total lymphoid irradiation (TLI) prior to bone marrow transplantation in severe aplastic anemia, low dose TBI in the treatment of lymphocytic leukemias or lymphomas, and hemibody irradiation (HBI) in the treatment of advanced multiple myeloma. Although accurate provision of a specific dose and the desired degree of dose homogeneity are two of the physicist's major considerations for all radiotherapy techniques, these tasks are even more demanding for large field radiotherapy. Because most large field radiotherapy is done at an extended distance for complex patient geometries, basic dosimetry data measured at the standard distance (isocenter) must be verified or supplemented. This paper discusses some of the special dosimetric problems of large field radiotherapy, with specific examples given of the dosimetry of the TBI program for bone marrow transplant at the authors' hospital

  3. Total body irradiation

    International Nuclear Information System (INIS)

    Barrett, A.

    1988-01-01

    This paper describes body irradiation (TBI) being used increasingly as consolidation treatment in the management of leukaemia, lymphoma and various childhood tumours with the aim of sterilizing any malignant cells or micrometastases. Systemic radiotherapy as an adjunct to chemotherapy offers several possible benefits. There are no sanctuary sites for TBI; some neoplastic cells are very radiosensitive, and resistance to radiation appears to develop less readily than to drugs. Cross-resistance between chemotherapy and radiotherapy does not seem to be common and although plateau effects may be seen with chemotherapy there is a linear dose-response curve for clonogenic cell kill with radiation

  4. Total body water and total body potassium in anorexia nervosa

    Energy Technology Data Exchange (ETDEWEB)

    Dempsey, D.T.; Crosby, L.O.; Lusk, E.; Oberlander, J.L.; Pertschuk, M.J.; Mullen, J.L.

    1984-08-01

    In the ill hospitalized patient with clinically relevant malnutrition, there is a measurable decrease in the ratio of the total body potassium to total body water (TBK/TBW) and a detectable increase in the ratio of total exchangeable sodium to total exchangeable potassium (Nae/Ke). To evaluate body composition analyses in anorexia nervosa patients with chronic uncomplicated semistarvation, TBK and TBW were measured by whole body K40 counting and deuterium oxide dilution in 10 females with stable anorexia nervosa and 10 age-matched female controls. The ratio of TBK/TBW was significantly (p less than 0.05) higher in anorexia nervosa patients than controls. The close inverse correlation found in published studies between TBK/TBW and Nae/Ke together with our results suggest that in anorexia nervosa, Nae/Ke may be low or normal. A decreased TBK/TBW is not a good indicator of malnutrition in the anorexia nervosa patient. The use of a decreased TBK/TBW ratio or an elevated Nae/Ke ratio as a definition of malnutrition may result in inappropriate nutritional management in the patient with severe nonstressed chronic semistarvation.

  5. Total body water and total body potassium in anorexia nervosa

    International Nuclear Information System (INIS)

    Dempsey, D.T.; Crosby, L.O.; Lusk, E.; Oberlander, J.L.; Pertschuk, M.J.; Mullen, J.L.

    1984-01-01

    In the ill hospitalized patient with clinically relevant malnutrition, there is a measurable decrease in the ratio of the total body potassium to total body water (TBK/TBW) and a detectable increase in the ratio of total exchangeable sodium to total exchangeable potassium (Nae/Ke). To evaluate body composition analyses in anorexia nervosa patients with chronic uncomplicated semistarvation, TBK and TBW were measured by whole body K40 counting and deuterium oxide dilution in 10 females with stable anorexia nervosa and 10 age-matched female controls. The ratio of TBK/TBW was significantly (p less than 0.05) higher in anorexia nervosa patients than controls. The close inverse correlation found in published studies between TBK/TBW and Nae/Ke together with our results suggest that in anorexia nervosa, Nae/Ke may be low or normal. A decreased TBK/TBW is not a good indicator of malnutrition in the anorexia nervosa patient. The use of a decreased TBK/TBW ratio or an elevated Nae/Ke ratio as a definition of malnutrition may result in inappropriate nutritional management in the patient with severe nonstressed chronic semistarvation

  6. Chaotic Zones around Rotating Small Bodies

    Energy Technology Data Exchange (ETDEWEB)

    Lages, José; Shevchenko, Ivan I. [Institut UTINAM, Observatoire des Sciences de l’Univers THETA, CNRS, Université de Franche-Comté, Besançon F-25030 (France); Shepelyansky, Dima L., E-mail: jose.lages@utinam.cnrs.fr [Laboratoire de Physique Théorique du CNRS, IRSAMC, Université de Toulouse, UPS, Toulouse F-31062 (France)

    2017-06-01

    Small bodies of the solar system, like asteroids, trans-Neptunian objects, cometary nuclei, and planetary satellites, with diameters smaller than 1000 km usually have irregular shapes, often resembling dumb-bells or contact binaries. The spinning of such a gravitating dumb-bell creates around it a zone of chaotic orbits. We determine its extent analytically and numerically. We find that the chaotic zone swells significantly if the rotation rate is decreased; in particular, the zone swells more than twice if the rotation rate is decreased 10 times with respect to the “centrifugal breakup” threshold. We illustrate the properties of the chaotic orbital zones in examples of the global orbital dynamics about asteroid 243 Ida (which has a moon, Dactyl, orbiting near the edge of the chaotic zone) and asteroid 25143 Itokawa.

  7. Density distortion within a rotating body

    International Nuclear Information System (INIS)

    Lanzano, P.

    1975-01-01

    This paper ascertains the distortion of the density distribution within a self-gravitating body in hydrostatic equilibrium under the influence of rotation. For this purpose, the Poisson equation has been solved by using the undistorted density profile within the Laplacian to obtain the distorted density. The Laplacian has been expressed in terms of a system of curvilinear coordinates for which the equipotential surfaces constitute a family of fundamental surfaces. In performing the requisite algebraic manipulations, the Clairaut and Radau equations developed in a previous paper (Lanzano,1974) were utilized to eliminate the derivatives of the elements pertaining to the equipotential surfaces. The density distortion has been obtained up to third-order terms in a small rotational parameter. (Auth.)

  8. Oscillation measuring device for body of rotation

    International Nuclear Information System (INIS)

    Komita, Hideo.

    1994-01-01

    The present invention concerns an internal pump of a BWR type reactor and provides a device for detecting oscillations of a rotational shaft. Namely, recesses are formed along an identical circumference on the outer circumferential surface of the rotating portion each at a predetermined distance. The recesses rotate along with the rotation. An eddy current type displacement gage measures the distance to the outer circumferential surface of the rotating portion. The recesses are detected by the displacement gage as pulse signals. When the rotating portion oscillates, it is detected by the displacement gage as waveform signals. Accordingly, the output signals of the eddy current type displacement gage are formed by pulse signals superposed on the waveform signals. A rising detection circuit detects the rising position of the pulse signals as the components of the number of rotation of the rotating portion, and fall detection circuit detects the falling position. A comparator circuit is disposed in parallel with both of rising/falling detection circuits. A predetermined threshold value is set in the comparator circuit to output a signal when the inputted signal exceeds the value. (I.S.)

  9. Cataract incidence after total-body irradiation

    International Nuclear Information System (INIS)

    Zierhut, D.; Lohr, F.; Schraube, P.; Huber, P.; Haas, R.; Hunstein, W.; Wannenmacher, M.

    1997-01-01

    Purpose: Aim of this retrospective study was to evaluate cataract incidence in a homogeneous group of patients after total-body irradiation followed by autologous bone marrow transplantation or peripheral blood stem cell transplantation. Method and Materials: Between 11/1982 and 6/1994 in total 260 patients received in our hospital total-body irradiation for treatment of haematological malignancy. In 1996-96 patients out of these 260 patients were still alive. 85 from these still living patients (52 men, 33 women) answered evaluable on a questionnaire and could be examined ophthalmologically. Median age of these patients was 38,5 years (15 - 59 years) at time of total-body irradiation. Radiotherapy was applied as hyperfractionated total-body irradiation with a median dose of 14,4 Gy in 12 fractions over 4 days. Minimum time between fractions was 4 hours, photons with a energy of 23 MeV were used, and the dose rate was 7 - 18 cGy/min. Results: Median follow-up is now 5,8 years (1,7 - 13 years). Cataract occurred in (28(85)) patients after a median time of 47 months (1 - 104 months). In 6 out of these 28 patients who developed a cataract, surgery of the cataract was performed. Whole-brain irradiation prior to total-body irradiation was more often in the group of patients developing a cataract (14,3%) vs. 10,7% in the group of patients without cataract. Conclusion: Cataract is a common side effect of total-body irradiation. Cataract incidence found in our patients is comparable to results of other centres using a fractionated regimen for total-body irradiation. The hyperfractionated regimen used in our hospital does obviously not result in a even lower cataract incidence. In contrast to acute and late toxicity in other organ/organsystems, hyperfractionation of total-body irradiation does not further reduce toxicity for the eye-lens. Dose rate may have more influence on cataract incidence

  10. Therapeutic use of fractionated total body and subtotal body irradiation

    International Nuclear Information System (INIS)

    Loeffler, R.K.

    1981-01-01

    Ninety-one patients were treated using fractionated subtotal body (STBI) or total body irradiation (TBI). These patients had generalized lymphomas, Hodgkin's disease, leukemias, myelomas, seminomas, or oat-cell carcinomas. Subtotal body irradiation is delivered to the entire body, except for the skull and extremities. It was expected that a significantly higher radiation dose could be administered with STBI than with TBI. A five- to ten-fold increase in tolerance for STBI was demonstrated. Many of these patients have had long-term emissions. There is little or no treatment-induced symptomatology, and no sanctuary sites

  11. A method for total body irradiation

    International Nuclear Information System (INIS)

    Yasukochi, Hiroshi; Higashi, Shizuka; Okuhata, Yoshitaka; Lee, Keiichi; Ishioka, Kuniaki; Murakami, Koji; Nagai, Jun; Kuniyasu, Yoshio

    1988-01-01

    In these two years, we have treated four infant patients of acute leukemia by Cobalt-60 total body irradiation and bone marrow transplantation. During total body irradiation, thermoluminescence dosimeters were attached to the skin of patients. For four patients, nine dosimetries were performed. Reliability of this method was examined by phantom experiment. Every irradiation for the patient per fraction was 2.4 Gy, that is, 60 cGy for each four positions, right decubitus A-P and PA directions and left decubitus A-P and PA directions under aseptic circumstances. Radiation dose was uniform by this technique for each patient, and average determined dose for surface of the patients was between 87 % and 106 % compared with the air dose of the center of aseptic space (wagon). As the result, we suggest that this method is suitable for the total body irradiation of acute leukemia of infant. (author)

  12. Evolution of rotating stars. III. Predicted surface rotation velocities for stars which conserve total angular momentum

    International Nuclear Information System (INIS)

    Endal, A.S.; Sofia, S.

    1979-01-01

    Predicted surface rotation velocities are presented for Population I stars at 10, 7, 5, 3, and 1.5M/sub sun/. The surface velocities have been computed for three different cases of angular momentum redistribution: no radial redistribution (rotation on decoupled shells), complete redistribution (rigid-body rotation), and partial redistribution as predicted by detailed consideration of circulation currents in rotation stars. The velocities for these cases are compared to each other and to observed stellar rotation rates (upsilon sin i).Near the main sequence, rotational effects can substantially reduce the moment of inertia of a star, so nonrotating models consistently underestimate the expected velocities for evolving stars. The magnitude of these effects is sufficient to explain the large numbers of Be stars and, perhaps, to explain the bimodal distribution of velocities observed for the O stars.On the red giant branch, angular momentum redistribution reduces the surface velocity by a factor of 2 or more, relative to the velocity expected for no radial redistribution. This removes the discrepancy between predicted and observed rotation rates for the K giants and makes it unlikely that these stars lose significant amounts of angular momentum by stellar winds. Our calculations indicate that improved observations (by the Fourier-transform technique) of the red giants in the Hyades cluster can be used to determine how angular momentum is redistributed by convection

  13. Femoral sizing in total knee arthroplasty is rotation dependant.

    Science.gov (United States)

    Koninckx, Angelique; Deltour, Arnaud; Thienpont, Emmanuel

    2014-12-01

    The mismatch between the medio-lateral (ML) and the antero-posterior (AP) size of femoral components in total knee arthroplasty (TKA) has been linked to gender, ethnicity, morphotype and height differences in patients. The hypothesis of this study was that the AP size measurement of a femoral component increases with more external rotation in posterior referencing TKA. During a 2-year period, 201 patients were included in this prospective study. The AP distance of the distal femur was measured with an AP sizer of the Vanguard (Biomet, Warsaw, US) knee system. This AP sizer allows to dial in external rotation by 1° increments and to determine the femoral size with an anterior boom. AP size was noted at 0°, 3° and 5° of external rotation and then compared for ML matching. Antero-posterior and corresponding ML sizes match perfectly for the Vanguard at 0° of external rotation and a central boom position on the anterior femoral surface. Then, the anterior boom was positioned on the antero-lateral cortex and the AP size increased a mean (SD) 1 (0.5) mm. With 3° of external rotation, the AP size increased a mean (SD) 2.3 (0.4) mm and for 5° a mean (SD) 3.8 (0.3) mm (P external rotation that is dialled in during surgery. Since these parameters vary case per case, the availability of narrow components offers more surgical options to the surgeon and its importance extends beyond the gender aspect allowing different amounts of external rotation to be used without ML overhang. II.

  14. Total Body Opacification 'Technique Neonatal Adrenal Haemorrhage

    African Journals Online (AJOL)

    1971-12-11

    Dec 11, 1971 ... A case is reported illustrating the possible usefulness of total body opacification in the diagnosis of neonatal adrenal haemorrhage. To derive maximum benefit from this principle, the routine use of an early film coupled with high dosage is urged whenever an intravenous pyelogram is performed for ...

  15. Implantation of total body irradiation in radiotherapy

    International Nuclear Information System (INIS)

    Habitzreuter, Angela Beatriz

    2010-01-01

    Before implementing a treatment technique, the characteristics of the beam under irradiation conditions must be well acknowledged and studied. Each one of the parameters used to calculate the dose has to be measured and validated before its utilization in clinical practice. This is particularly necessary when dealing with special techniques. In this work, all necessary parameters and measurements are described for the total body irradiation implementation in facilities designed for conventional treatments that make use of unconventional geometries to generate desired enlarged field sizes. Furthermore, this work presents commissioning data of this modality at Hospital das Clinicas of Sao Paulo using comparison of three detectors types for measurements of entrance dose during total body irradiation treatment. (author)

  16. Use of total body electrical conductivity (TOBEC) to determine total body water

    International Nuclear Information System (INIS)

    Cochran, W.; Wong, W.; Sheng, H.P.; Klein, P.; Klish, W.

    1986-01-01

    Total body electrical conductivity (TOBEC) has been introduced as a safe and rapid method to estimate body composition in infants and adults. Recently, a second generation instrument that operates in a scanning mode has been developed. A study was undertaken to calibrate this new instrument and to assess the feasibility of its use in estimating total body water. Six healthy adults, 3 males and 3 females, ranging in age from 25 to 57 years, and in weight from 43.3 to 104.7 kg were analyzed. Simultaneously, determinations of total body water were made by standard dilutional techniques using H 2 18 O. A baseline plasma sample was obtained and 60 mg 18 O/kg was given orally as H 2 18 O. Five hr later, a postdose plasma sample was obtained. The 18 O/ 16 O ratio in the plasma samples was determined as CO 2 by gas-isotope-ratio mass spectrometry and used to calculate the H 2 18 O volume of distribution. The total body water values ranged from 26.35 to 58.02 and represented 51 to 58% of body weight. There was good linear correlation between the total body water measurement and its phase average (TOBEC number) with a linear correlation coefficient of 0.998. The standard error of the estimate was 0.98. In addition to estimating fat and fat-free mass, the TOBEC method also estimates total body water with excellent correlation to physical dilutions methods

  17. Importance of body rotation during the flight of a butterfly.

    Science.gov (United States)

    Fei, Yueh-Han John; Yang, Jing-Tang

    2016-03-01

    In nature the body motion of a butterfly is clearly observed to involve periodic rotation and varied flight modes. The maneuvers of a butterfly in flight are unique. Based on the flight motion of butterflies (Kallima inachus) recorded in free flight, a numerical model of a butterfly is created to study how its flight relates to body pose; the body motion in a simulation is prescribed and tested with varied initial body angle and rotational amplitude. A butterfly rotates its body to control the direction of the vortex rings generated during flapping flight; the flight modes are found to be closely related to the body motion of a butterfly. When the initial body angle increases, the forward displacement decreases, but the upward displacement increases within a stroke. With increased rotational amplitudes, the jet flows generated by a butterfly eject more downward and further enhance the generation of upward force, according to which a butterfly executes a vertical jump at the end of the downstroke. During this jumping stage, the air relative to the butterfly is moving downward; the butterfly pitches up its body to be parallel to the flow and to decrease the projected area so as to avoid further downward force generated. Our results indicate the importance of the body motion of a butterfly in flight. The inspiration of flight controlled with body motion from the flight of a butterfly might yield an alternative way to control future flight vehicles.

  18. Rotational total skin electron irradiation with a linear accelerator

    Science.gov (United States)

    Evans, Michael D.C.; Devic, Slobodan; Parker, William; Freeman, Carolyn R.; Roberge, David; Podgorsak, Ervin B.

    2008-01-01

    The rotational total skin electron irradiation (RTSEI) technique at our institution has undergone several developments over the past few years. Replacement of the formerly used linear accelerator has prompted many modifications to the previous technique. With the current technique, the patient is treated with a single large field while standing on a rotating platform, at a source‐to‐surface distance of 380 cm. The electron field is produced by a Varian 21EX linear accelerator using the commercially available 6 MeV high dose rate total skin electron mode, along with a custom‐built flattening filter. Ionization chambers, radiochromic film, and MOSFET (metal oxide semiconductor field effect transistor) detectors have been used to determine the dosimetric properties of this technique. Measurements investigating the stationary beam properties, the effects of full rotation, and the dose distributions to a humanoid phantom are reported. The current treatment technique and dose regimen are also described. PACS numbers: 87.55.ne, 87.53.Hv, 87.53.Mr

  19. Measurement of total body radioactivity in man

    International Nuclear Information System (INIS)

    Naversten, Y.

    1982-01-01

    Techniques for the determination of whole-body radioactivity in man using uncollimated NaI(Tl) detectors have been studied. Geometrical effects and photon attenuation effects due to the different shapes of humans as well as due to varying in-vivo radioactivity distributions have been evaluated particularly for scanning-bed geometries and the chair geometry. Theoretically it is shown that the attenuation effects are generally dominating, for full-energy-peak pulse-range methods. For the application in radiation protection a cheap and simple chair-geometry unit has been constructed and used at various places distantly from the home-laboratory, for studies of body activity of Cs-137 in northern Sweden. High body activities were found particularly in reindeer-breeding Lapps. The elimination rate of Cs-137 in man was studied in the stationary whole-body counter in Lund as well as with the field-system. For the study of the performances at low and high photon energies clinical applications of methods for gastro-intestinal absorption of vitamin B12 (Co-57; 122 keV) and total body potassium determination (K-40; 1.46 MeV, K-42; 1.52 MeV) have been evaluated. Theoretical and experimental results as well as experiences of applications in radiation protection and medicine show that the scanning-bed geometry effectively evens out redistributional effects. For optimum results, however, scatter-energy pulse-ranges rather than full-energy-peak ranges should be used. (Auth.)

  20. Total body irradiation for children with malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Sanuki, Eiichi; Maeno, Toshio; Kamata, Rikisaburo; Tanaka, Yoshiaki; Mugishima, Hideo [Nihon Univ., Tokyo (Japan). School of Medicine

    1995-12-01

    Total body irradiation combined with high dose chemotherapy has been performed just before bone marrow transplantation in 35 children with advanced malignancies, with the object of achieving successful transplantation and improving the prognosis. Simulation was performed as follows: back scatter, flatness, dose accumulation using randophantom and dose distribution using a thermo-luminescence dosimeter and linac-graphy. The standard error of dose distribution was within 10%. In neuroblastoma, of which there were 14 cases in stage IV and one case in stage III, the 5-year survival rate was 55%. In leukemia, of which all cases were in the high-risk group (7 cases of acute lymphoblastic leukemia and 2 of acute myeloblastic leukemia) the 5-year survival rate was 55%. The 5 cases having first remission survived disease-free while the 4 cases having non-first remission died. In malignant lymphoma (6 cases in stage IV and one case in stage III, with bulky mass) the 5-year survival rate was 67%. Four cases with other diagnoses (severe aplastic anemia, and others) all survived. As yet no side effects resulting from total body irradiation have been recognized in our cases, but a longer follow-up period is necessary to observe possible late side effects. (author).

  1. Total body photography for skin cancer screening.

    Science.gov (United States)

    Dengel, Lynn T; Petroni, Gina R; Judge, Joshua; Chen, David; Acton, Scott T; Schroen, Anneke T; Slingluff, Craig L

    2015-11-01

    Total body photography may aid in melanoma screening but is not widely applied due to time and cost. We hypothesized that a near-simultaneous automated skin photo-acquisition system would be acceptable to patients and could rapidly obtain total body images that enable visualization of pigmented skin lesions. From February to May 2009, a study of 20 volunteers was performed at the University of Virginia to test a prototype 16-camera imaging booth built by the research team and to guide development of special purpose software. For each participant, images were obtained before and after marking 10 lesions (five "easy" and five "difficult"), and images were evaluated to estimate visualization rates. Imaging logistical challenges were scored by the operator, and participant opinion was assessed by questionnaire. Average time for image capture was three minutes (range 2-5). All 55 "easy" lesions were visualized (sensitivity 100%, 90% CI 95-100%), and 54/55 "difficult" lesions were visualized (sensitivity 98%, 90% CI 92-100%). Operators and patients graded the imaging process favorably, with challenges identified regarding lighting and positioning. Rapid-acquisition automated skin photography is feasible with a low-cost system, with excellent lesion visualization and participant acceptance. These data provide a basis for employing this method in clinical melanoma screening. © 2014 The International Society of Dermatology.

  2. Control of fluid-containing rotating rigid bodies

    CERN Document Server

    Gurchenkov, Anatoly A

    2013-01-01

    This book is devoted to the study of the dynamics of rotating bodies with cavities containing liquid. Two basic classes of motions are analyzed: rotation and libration. Cases of complete and partial filling of cavities with ideal liquid and complete filling with viscous liquid are treated. The volume presents a method for obtaining relations between angular velocities perpendicular to main rotation and external force momentums, which are treated as control. The developed models and methods of solving dynamical problems as well as numerical methods for solving problems of optimal control can be

  3. Biological basis of total body irradiation

    International Nuclear Information System (INIS)

    Dubray, B.; Helfre, S.; Dendale, R.; Cosset, J.M.; Giraud, P.

    1999-01-01

    A comprehensive understanding of the radiobiological bases of total body irradiation (TBI) is made difficult by the large number of normal and malignant tissues that must be taken into account. In addition, tissue responses to irradiation are also sensitive to associated treatments, type of graft and a number of patient characteristics. Experimental studies have yielded a large body of data, the clinical relevance of which still requires definite validation through randomized trials. Fractionated TBI schemes are able to reduce late normal tissue toxicity, but the ultimate consequences of the fractional dose reduction do not appear to be equivocal. Thus, leukemia and lymphoma cells are probably more radio-biologically heterogeneous than previously thought, with several cell lines displaying relatively high radioresistance and repair capability patterns. The most primitive host-type hematopoietic stem cells are likely to be at least partly protected by TBI fractionation and may hamper late engraftment. Similarly, but with possibly conflicting consequences on the probability of engraftment, the persistence of a functional marrow stroma may also be fractionation-sensitive, while higher rejection rates have been reported after T-depletion grafts and fractionated TBI. in clinical practice (as for performance of relevant clinical trials), the influence of these results are rather limited by the heavy logistic constraints created by a sophisticated and time-consuming procedure. Lastly, clinicians are now facing an increasing incidence of second cancers, at least partly induced by irradiation, which jeopardize the long-term prospects of otherwise cured patients. (authors)

  4. Total-body sodium and sodium excess

    International Nuclear Information System (INIS)

    Aloia, J.F.; Cohn, S.H.; Abesamis, C.; Babu, T.; Zanzi, I.; Ellis, K.

    1980-01-01

    Total-body levels of sodium (TBNa), chlorine (TBCI), calcium (TBCa), and potassium (TBK) were measured by neutron activation and analysis of results by whole body counting in 66 postmenopausal women. The relationship between TBNa, and TBCl, TBK, and TBCa on the one hand, and height and weight on the other, were found to compare with those previously reported. The hypothesis that TBNa and TBCl are distributed normally could not be rejected. The sodium excess (Na/sub es/) is defined as the sodium that is present in excess of that associated with the extracellular fluid (chlorine) space; the Na/sub es/ approximates nonexchangeable bone sodium. In these 66 postmenopausal women, and in patients with different endocrinopathies previously described, the values on Na/sub es/ did not differ from the normal values except in the thyrotoxicosis patients, where they were decreased. A close relationship between Na/sub es/ and TBCa was maintained in the endocrinopathies studied. This relationship was found in conditions accompanied by either an increment or a loss of skeletal mass. It appears that the NA/sub es/ value is primarily dependent upon the calcium content of bone

  5. Visuospatial memory computations during whole-body rotations in roll

    NARCIS (Netherlands)

    Pelt, S. van; Gisbergen, J.A.M. van; Medendorp, W.P.

    2005-01-01

    We used a memory-saccade task to test whether the location of a target, briefly presented before a whole-body rotation in roll, is stored in egocentric or in allocentric coordinates. To make this distinction, we exploited the fact that subjects, when tilted sideways in darkness, make systematic

  6. Renal toxicity after total body irradiation

    International Nuclear Information System (INIS)

    Borg, Martin; Hughes, Timothy; Horvath, Noemi; Rice, Michael; Thomas, Anthony C.

    2002-01-01

    Purpose: To evaluate the incidence of renal dysfunction after total body irradiation (TBI). Methods and Materials: Between 1990 and 1997, 64 patients (median age 50 years) received TBI as part of the conditioning regimen before bone marrow transplantation (BMT). Five patients with abnormal renal function at the beginning of treatment or with incomplete data were excluded. All patients received a total of 12 Gy (6 fractions twice daily for 3 consecutive days) prescribed to the peak lung dose (corrected for lung transmission) at a dose rate of 7.5 cGy/min. Renal shielding was not used. Renal dysfunction was assessed on the basis of the serum creatinine levels measured at the start and end of TBI and at 6, 12, 18, and 24 months after completion of BMT. Cox proportional hazard analysis was used to evaluate the various factors known to affect renal function. Results: Only 4 patients had elevated serum creatinine levels at 12 months and subsequently only 2 of the 33 surviving patients had persistent elevated renal serum creatinine levels 24 months after BMT. A fifth patient developed proteinuria and mildly elevated serum creatinine levels at 2.5 years. In 2 patients, the elevation coincided with disease relapse and normalized once remission was achieved. In the third patient, the elevation in serum creatinine levels coincided with relapse of multiple myeloma and the presence of Bence-Jones proteinuria. The fourth patient was the only patient who developed chronic renal failure secondary to radiation nephritis at 2 years. The etiology of the fifth patient's rise in creatinine was unknown, but may have been secondary to radiation nephritis. On univariate analysis, but not on multivariate analysis, a significant correlation was found between TBI-related renal dysfunction and hypertension before and after BMT. Conclusion: A dose of 12 Gy at 2 Gy/fraction resulted in only 1 case of radiation nephritis in the 59 patients studied 24 months after the completion of TBI and BMT

  7. Total body irradiation in bone marrow transplantation

    International Nuclear Information System (INIS)

    Gluckman, E.; Devergie, A.; Boiron, M.; Bernard, Jean; Dutreix, A.; Dutreix, J.

    1979-01-01

    Total body irradiation was used in 22 patients as part of their conditioning regimen for bone marrow transplantation. Nine patients with acute leukemia received 1000 cGy TBI in addition with chemotherapy. None of them survived and the main cause of death was interstitial pneumonitis (50%). 4 patients received 1000 cGy with a lung shielding of 500 cGy. Two patients with acute leukemia died of leukemia and sepsis, two patients had aplastic anemia, one is surviving, the other died of severe GVHD and infectious complications. Nine patients with severe aplastic anemia strongly immunized by previous blood transfusions received 800 cGy TBI with a lung shielding of 400 cGy. No rejection was observed and 7 patients (63%) are currently alive. One patient died of interstitial pneumonitis probably related to CMV infection, one of subacute necrotizing hepatitis, two of severe acute GVHD. It is concluded from this study that TBI remains the best immunosuppressive conditioning regimen even in strongly immunized patients. It may be a contributing factor of the incidence and severity of interstitial pneumonitis. A reduction of the dose of the lung to 400-500 cGy seems to decrease the severity of this complication

  8. Radiobiological speculations on therapeutic total body irradiation

    International Nuclear Information System (INIS)

    Vriesendorp, H.M.

    1990-01-01

    Unexpected total body irradiation (TBI) of human beings, involved in nuclear warfare or in accidents in nuclear reactors can be lethal. In the 1950s, bone marrow transplantation was discovered as a potentially life saving procedure after TBI in the dose range of 5.0 to 12.0 Gy. Since that time, deliberate or therapeutic TBI has been used to condition patients with a lethal bone marrow disorder for bone marrow replacement. The therapeutic ratio of TBI followed by bone marrow transplantation is small. Many potentially lethal complications can occur, such as acute TBI side effects, late TBI side effects or immunological complications of bone marrow transplantation such as graft versus host disease or graft rejection. The benefits of TBI and bone marrow transplantation are that they offer a chance for cure of previously lethal bone marrow disorders. The optimal parameters for TBI remain to be defined. The review discusses the current clinical and experimental animal data, as they relate to the future definition of less toxic TBI procedures with a better therapeutic ratio. Different TBI procedures are required for patients with malignant vs. non-malignant disorders or for patients with histoincompatible vs. histocompatible bone marrow donors.77 references

  9. Estimation of Total Body Fat from Potassium-40 Content

    International Nuclear Information System (INIS)

    Taha Mohamed Taha Ahmed, T.M.T.

    2010-01-01

    This paper concerns on estimation of total body fat from potassium 40 content using total body counting technique. The work performed using fast scan whole body counter. Calibration of that system for K-40 was carried out under assumption that uniformity distribution of radioactivity of potassium was distributed in 10 polyethylene bottles phantom. Different body sizes were represented by 2, 4, 6, 8 and 10 polyethylene bottles; each bottle has a volume of 0.04 m3. The counting efficiency for each body size was determined. Lean body weight (LBW) was calculated for ten males and ten females using appropriate mathematical equation. Total Body Potassium, TBK for the same selected group was measured using whole body counter. A mathematical relationship between lean body weight and potassium content was deduced .Fat contents for some individuals were calculated and weight/height ratio was indicated for fatness.

  10. Probable Rotation States of Rocket Bodies in Low Earth Orbit

    Science.gov (United States)

    Ojakangas, Gregory W.; Anz-Meador, P.; Cowardin, H.

    2012-01-01

    In order for Active Debris Removal to be accomplished, it is critically important to understand the probable rotation states of orbiting, spent rocket bodies. As compared to the question of characterizing small unresolved debris, in this problem there are several advantages: (1) objects are of known size, mass, shape and color, (2) they have typically been in orbit for a known period of time, (3) they are large enough that resolved images may be obtainable for verification of predicted orientation, and (4) the dynamical problem is simplified to first order by largely cylindrical symmetry. It is also nearly certain for realistic rocket bodies that internal friction is appreciable in the case where residual liquid or, to a lesser degree, unconsolidated solid fuels exist. Equations of motion have been developed for this problem in which internal friction as well as torques due to solar radiation, magnetic induction, and gravitational gradient are included. In the case of pure cylindrical symmetry, the results are compared to analytical predictions patterned after the standard approach for analysis of symmetrical tops. This is possible because solar radiation and gravitational torques may be treated as conservative. Agreement between results of both methods ensures their mutual validity. For monotone symmetric cylinders, solar radiation torque vanishes if the center of mass resides at the geometric center of the object. Results indicate that in the absence of solar radiation effects, rotation states tend toward an equilibrium configuration in which rotation is about the axis of maximum inertia, with the axis of minimum inertia directed toward the center of the earth. Solar radiation torque introduces a modification to this orientation. The equilibrium state is asymptotically approached within a characteristic timescale given by a simple ratio of relevant characterizing parameters for the body in question. Light curves are simulated for the expected asymptotic final

  11. Correlation of glenohumeral internal rotation deficit and total rotational motion to shoulder injuries in professional baseball pitchers.

    Science.gov (United States)

    Wilk, Kevin E; Macrina, Leonard C; Fleisig, Glenn S; Porterfield, Ronald; Simpson, Charles D; Harker, Paul; Paparesta, Nick; Andrews, James R

    2011-02-01

    Glenohumeral internal rotation deficit (GIRD) indicates a 20° or greater loss of internal rotation of the throwing shoulder compared with the nondominant shoulder. To determine whether GIRD and a deficit in total rotational motion (external rotation + internal rotation) compared with the nonthrowing shoulder correlate with shoulder injuries in professional baseball pitchers. Case series; Level of evidence, 4. Over 3 competitive seasons (2005 to 2007), passive range of motion measurements were evaluated on the dominant and nondominant shoulders for 170 pitcher-seasons. This included 122 professional pitchers during the 3 seasons of data collection, in which some pitchers were measured during multiple seasons. Ranges of motion were measured with a bubble goniometer during the preseason, by the same examiner each year. External and internal rotation of the glenohumeral joint was assessed with the participant supine and the arm abducted 90° in the plane of the scapula, with the scapula stabilized anteriorly at the coracoid process. The reproducibility of the test methods had an intraclass correlation coefficient of .81. Days in which the player was unable to participate because of injury or surgery were recorded during the season by the medical staff of the team and defined as an injury. Pitchers with GIRD (n = 40) were nearly twice as likely to be injured as those without but without statistical significance (P = .17). Pitchers with total rotational motion deficit greater than 5° had a higher rate of injury. Minor league pitchers were more likely than major league pitchers to be injured. However, when players were injured, major league pitchers missed a significantly greater number of games than minor league pitchers. Compared with pitchers without GIRD, pitchers with GIRD appear to be at a higher risk for injury and shoulder surgery.

  12. TH-A-9A-03: Dosimetric Effect of Rotational Errors for Lung Stereotactic Body Radiotherapy

    International Nuclear Information System (INIS)

    Lee, J; Kim, H; Park, J; Kim, J; Kim, H; Ye, S

    2014-01-01

    Purpose: To evaluate the dosimetric effects on target volume and organs at risk (OARs) due to roll rotational errors in treatment setup of stereotactic body radiation therapy (SBRT) for lung cancer. Methods: There were a total of 23 volumetric modulated arc therapy (VMAT) plans for lung SBRT examined in this retrospective study. Each CT image of VMAT plans was intentionally rotated by ±1°, ±2°, and ±3° to simulate roll rotational setup errors. The axis of rotation was set at the center of T-spine. The target volume and OARs in the rotated CT images were re-defined by deformable registration of original contours. The dose distributions on each set of rotated images were re-calculated to cover the planning target volume (PTV) with the prescription dose before and after the couch translational correction. The dose-volumetric changes of PTVs and spinal cords were analyzed. Results: The differences in D95% of PTVs by −3°, −2°, −1°, 1°, 2°, and 3° roll rotations before the couch translational correction were on average −11.3±11.4%, −5.46±7.24%, −1.11±1.38% −3.34±3.97%, −9.64±10.3%, and −16.3±14.7%, respectively. After the couch translational correction, those values were −0.195±0.544%, −0.159±0.391%, −0.188±0.262%, −0.310±0.270%, −0.407±0.331%, and −0.433±0.401%, respectively. The maximum dose difference of spinal cord among the 23 plans even after the couch translational correction was 25.9% at −3° rotation. Conclusions: Roll rotational setup errors in lung SBRT significantly influenced the coverage of target volume using VMAT technique. This could be in part compensated by the translational couch correction. However, in spite of the translational correction, the delivered doses to the spinal cord could be more than the calculated doses. Therefore if rotational setup errors exist during lung SBRT using VMAT technique, the rotational correction would rather be considered to prevent over-irradiation of normal

  13. Quality control of dosimetry in total body irradiation

    International Nuclear Information System (INIS)

    Kallinger, W.

    1986-11-01

    An on-line dose measurement system for the quality control of the treatment of leukemia by means of total body irradiation with Co-60 gamma radiation is introduced. An ionization chamber and 5 diodes arranged on the surface of the patient incorporated with a microprocessor provides useful information and data necessary for the treatment. Following the concerted treatment procedure employing this system, the treatment of leukemia by means of total body irradiation is expected to be improved

  14. Total body irradiation: current indications; L`irradiation corporelle totale: les indications actuelles

    Energy Technology Data Exchange (ETDEWEB)

    Giraud, P.; Danhier, S.; Dubray, B.; Cosset, J.M. [Institut Curie, 75 - Paris (France)

    1998-05-01

    The choice of dose and fractionation for total body irradiation is made difficult by the large number of considerations to be taken into account. The outcome of bone marrow transplantation after total body irradiation can be understood in terms of tumor cell killing, engraftment, and normal tissue damage, each of these endpoints being influenced by irradiation-, disease-, transplant-, and patient- related factors. Interpretation of clinical data is further hampered by the overwhelming influence of logistic constraints, the small numbers of randomized studies, and the concomitant variations in total dose and fraction size or dose rate. So far, three cautious conclusions can be drawn in order to tentatively adapt the total body irradiation schedule to clinically-relevant situations. Firstly, the organs at risk for normal tissue damage (lung, liver, lens, kidney) are protected by delivering small doses per fraction at low dose rate. This suggests that, when toxicity is at stake (e.g. in children), fractionated irradiation should be preferred, provided that inter-fraction intervals are long enough. Secondly, fractionated irradiation should be avoided in case of T-cell depleted transplant, given the high risk of graft rejection in this setting. An alternative would be to increase total (or fractional) dose of fractionated total body irradiation, but this approach is likely to induce more normal tissue toxicity. Thirdly, clinical data have shown higher relapse rates in chronic myeloid leukemia after fractionated or low dose rate total body irradiation, suggesting that fractionated irradiation should not be recommended, unless total (or fractional) dose is increased. Total body irradiation-containing regimens, primarily cyclophosphamide / total body irradiation, are either equivalent to or better than the chemotherapy-only regimens, primarily busulfan / cyclophosphamide. Busulfan / cyclophosphamide certainly represents a reasonable alternative, especially in patients who

  15. Tibial internal rotation negatively affects clinical outcomes in total knee arthroplasty: a systematic review.

    Science.gov (United States)

    Panni, Alfredo Schiavone; Ascione, Francesco; Rossini, Marco; Braile, Adriano; Corona, Katia; Vasso, Michele; Hirschmann, Michael T

    2017-12-15

    The aim of this systematic review is to analyze the effect of tibial rotational alignment after total knee arthroplasty (TKA) on clinical outcomes and assess the eventual cut-off values for tibial TKA rotation leading to poor outcomes. A detailed and systematic search from 1997 to 2017 of the Pubmed, Medline, Cochrane Reviews, and the Google Scholar databases was performed using the keyword terms "total knee arthroplasty", "total knee replacement", "tibial alignment", "tibial malalignement", "tibial rotation", "rotational error", "axis", "angle", "tibial malrotation", "clinical outcome", in several combinations. The modified Coleman scoring methodology (mCMS) was used. All the primary TKAs studies analyzing correlation between clinical results and tibial rotation were included. Five articles met the inclusion criteria. A total of 333 arthroplasties were included in this review; 139 had tibial component malalignment, while 194 were in control groups. The mean age of patients was 67.3 (SD 0.57) years. The mean average postoperative follow-up delay was 34.7 months (range 21-70). The mean mCMS score was 59.2 points indicating good methodological quality in the included studies. Functional outcomes were assessed through KSS, OKS, KOOS and VAS, negatively related to tibial internal rotation. Our review confirmed that excessive internal rotation of the tibial TKA component represents a significant risk factor for pain and inferior functional outcomes after TKA (> 10° of internal rotation demonstrated the common value), since external rotation does not affect the results. However, a universal precise cut-off value has not been found in the available literature and there remains a debate about CT rotation assessment and surgical intra-operative landmarks. III.

  16. Total body and regional bone mineral content in hemodialysis patients

    International Nuclear Information System (INIS)

    Hagiwara, Satoshi; Aratani, Hideyui; Miki, Takami; Nishizawa, Yoshiki; Okamura, Terue; Koizumi, Yoshiko; Ochi, Hironobu; Morii, Hirotoshi

    1994-01-01

    Bone mineral content (BMC) in the total body and lumbar spine was evaluated in 126 hemodialysis patients (60 males, 66 females) by dual photon absorptiometry with the Norland DBD 2600. Measurements of: 1) total body BMC divided by lean body mass (BMC TB /LBM), 2) bone mineral density (BMD) of total body, 3) BMD of four regional sections (head, trunk, pelvis, and legs), and 4) BMD of lumbar spine, generally showed a significant decrease in the hemodialysis patients compared to the reference population. However, arm BMD did not show a significant difference between patients and control populations. The z-score of BMC TB /LBM declined significantly throughout the duration of hemodialysis, although that of the lumbar spine BMD did not. It should be noted that the degree of decrease in BMC was more prominent in the total body measurement than in the lumbar spine measurement. There was preferential osteopenia of the total body in the hemodialysis patients. Although the lumbar spine BMD showed a lower value than the control population, the lumbar spine is not the recommended region to monitor the BMD change in hemodialysis patients. (author)

  17. Total body irradiation with a reconditioned cobalt teletherapy unit.

    Science.gov (United States)

    Evans, Michael D C; Larouche, Renée-Xavière; Olivares, Marina; Léger, Pierre; Larkin, Joe; Freeman, Carolyn R; Podgorsak, Ervin B

    2006-01-01

    While the current trend in radiotherapy is to replace cobalt teletherapy units with more versatile and technologically advanced linear accelerators, there remain some useful applications for older cobalt units. The expansion of our radiotherapy department involved the decommissioning of an isocentric cobalt teletherapy unit and the replacement of a column-mounted 4-MV LINAC that has been used for total body irradiation (TBI). To continue offering TBI treatments, we converted the decommissioned cobalt unit into a dedicated fixed-field total body irradiator and installed it in an existing medium-energy LINAC bunker. This article describes the logistical and dosimetric aspects of bringing a reconditioned cobalt teletherapy unit into clinical service as a total body irradiator.

  18. Effect of limb rotation on radiographic alignment in total knee arthroplasties.

    Science.gov (United States)

    Radtke, Kerstin; Becher, Christoph; Noll, Yvonne; Ostermeier, Sven

    2010-04-01

    Even in a well-aligned total knee arthroplasty (TKA), limb rotation at the time of radiographic assessment will alter the measurement of alignment. This could influence the radiographic outcome of TKA. The purpose of this study was to evaluate the effect of limb rotation on radiographic alignment after TKA and to establish a re-calculation of this rotation by using existing radiographic landmarks. Synthetic femur and tibia (Sawbones), Inc. Vashon Island, WA) were used to create a TKA of the Triathlon knee prosthesis system (Stryker), Limerick, Ireland). The femoral alignment was 6.5 degrees valgus. The model was fixed in an upright stand. Five series of nine anteroposterior (AP) long leg radiographs were taken on a 30 cm x 120 cm plates in full extension with the limb rotated, in 5 degrees increments, from 20 degrees external rotation to 20 degrees internal rotation. After digitizing each radiograph (Scanner Hewlett Packard XJ 527), an observer measured the anatomic mechanical angle of the femur [AMA ( degrees )], the mechanical lateral proximal femur angle [mLPFA ( degrees )], the mechanical lateral distal femur angle [mLDFA ( degrees )], the mechanical medial proximal tibia angle [mMPTA ( degrees )] and the mechanical lateral distal tibia angle [mLDTA ( degrees )] using a digital measurement software (MediCAD, Hectec, Altfraunhofen, Germany). Besides, the observer measured the geometrical distances of the femoral component figured on the long leg radiograph. A ratio of one distance to another was measured (called femoral component distance ratio). The average radiographic anatomic alignment ranged from 6.827 degrees AMA (SD = 0.22 degrees ) in 20 degrees internal rotation to 4.627 degrees AMA (SD = 0.22 degrees ) in 20 degrees external rotation. Average mLPFA ( degrees ) ranged from 101.63 degrees (SD = 0.63) in 20 degrees internal rotation to 93.60 degrees (SD = 0.74 degrees ) in 20 degrees external rotation. Average mLDFA ( degrees ) ranged from 90.59 degrees

  19. Acute tolerance of hyperfractionated accelerated total body irradiation

    International Nuclear Information System (INIS)

    Latz, D.; Schraube, P.; Wannenmacher, M.

    1996-01-01

    Background: Acute side effects of total body irradiation lead to intense molestations of the patients. Therefore, it is desirable to take measures to reduce these side effects. In a retrospective study the frequency on acute side effects of a hyperfractionated accelerated total body irradiation was assessed and compared to frequencies of other exposure schedules published in the literature. Additionally the influence of ondansetron on the frequency of nausea and vormiting was investigated. Patients and Method: From 1989 to 1992, 76 patients (47 male, 29 female; median age 38 years) underwent total body irradiation before autologeous bone marrow transplantation. They received 3 daily doses of 1.20 Gy each every 4 h on 4 successive days to a total dose of 14,40 Gy. Thirty-nine patients received 3x8 mg (daily, intravenous or per os) ondansetron during the whole course of irradiation. Results: The most relevant side effects were nausea and vomiting. Patients, who did not receive ondansetron (n=37) showed a nausea and emesis rate of 73%. With ondansetron (n=39) nausea and emesis were reduced to 38%. Also the grade of severity of these side effects was reduced. Conclusions: Ondansetron proved to be an effective medicament for relieving nausea and vormiting during total body irradiation. The results obtained are in concordance with those published in the literature. (orig.) [de

  20. Laboratory tests of catastrophic disruption of rotating bodies

    Science.gov (United States)

    Morris, A. J. W.; Burchell, M. J.

    2017-11-01

    The results of catastrophic disruption experiments on static and rotating targets are reported. The experiments used cement spheres of diameter 10 cm as the targets. Impacts were by mm sized stainless steel spheres at speeds of between 1 and 7.75 km s-1. Energy densities (Q) in the targets ranged from 7 to 2613 J kg-1. The experiments covered both the cratering and catastrophic disruption regimes. For static, i.e. non-rotating targets the critical energy density for disruption (Q*, the value of Q when the largest surviving target fragment has a mass equal to one half of the pre-impact target mass) was Q* = 1447 ± 90 J kg-1. For rotating targets (median rotation frequency of 3.44 Hz) we found Q* = 987 ± 349 J kg-1, a reduction of 32% in the mean value. This lower value of Q* for rotating targets was also accompanied by a larger scatter on the data, hence the greater uncertainty. We suggest that in some cases the rotating targets behaved as static targets, i.e. broke up with the same catastrophic disruption threshold, but in other cases the rotation helped the break up causing a lower catastrophic disruption threshold, hence both the lower value of Q* and the larger scatter on the data. The fragment mass distributions after impact were similar in both the static and rotating target experiments with similar slopes.

  1. Patient reported activities after reverse total shoulder arthroplasty in rotator cuff arthropathy patients.

    Science.gov (United States)

    Alcobía-Díaz, B; Lópiz, Y; García-Fernández, C; Rizo de Álvaro, B; Marco, F

    Reverse total shoulder arthroplasty in rotator cuff arthropathy patients, improves anteversion and abduction, but not rotational, outcomes. The main aim of this study is to determine its repercussions on daily life activities in our patients. Between 2009 and 2011 we implanted 210 shoulder arthroplasties, 126 of them were reverse total shoulder arthroplasty in a rotator cuff arthropathy context. About 88% were women, with a mean age at time of surgery of 81 years, 95% were retired. The mean follow up was 53 months. The Constant scale, Visual Analogue Scale, Charlson Comorbidity Index, range of motion were measured for each patient and whether they could manage 40 daily life activities by means of a new questionnaire, classifying them according toshoulder functional demand. Mean normalized by sex and age Constant value was 81.2%. Mean Visual Analogue Scale and Charlson Index were 3.56 and 1.69 respectively. Improvement in anteversion and abduction, not in rotational range of motion. Limitation was found in low and high functional demand activities in 20% and 51% respectively, especially those which involved internal rotation. Reverse total shoulder arthroplasty treatment for RCA in the elderly, achieves adequate pain management and good functional outcomes. Nevertheless, an important risk of DLA limitation must be accepted in those which involve internal rotation or shoulder high functional demand. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Analogies between oscillation and rotation of bodies induced or influenced by vortex shedding

    Science.gov (United States)

    Lugt, H. J.

    Vortex-induced or vortex-influenced rotation and oscillation of bodies in a parallel flow are discussed. A steady flow occurs if the body axis is parallel to the flow or if the axis of rotation is perpendicular to the flow. Flows around an oscillating body are quasi-steady only if the Strougal number is much smaller than unity. The connection between rotation and oscillation is demonstrated in terms of the autorotation of a Lanchester propeller, and conditions for stable autorotation are defined. The Riabouchinsky curve is shown to be typical of forces and torques on bodies with vortical wakes, including situations with fixed body axes perpendicular to the flow. A differential equation is formulated for rotational and oscillating bodies that shed vortices by extending the pendulum equation to include vortical effects expressed as a fifth-order polynomial.

  3. Structure and stability of rapidly rotating fluid bodies in general relativity. II. The structure of uniformly rotating pseudopolytropes

    International Nuclear Information System (INIS)

    Butterworth, E.M.

    1976-01-01

    A method is described for obtaining numerical solutions to the exact Einstein field equations that represent uniformly rotating perfect fluid bodies which are stationary and obey equations of state of the form (pressure) proportional (energy density) 1+1 //subn/. Sequences parametrized by the rate of rotation are generated for polytropic indices n between 0.5 and 3 and for varying strengths of relativity. All are found to terminate at surface velocities which are approximately 10 percent or more of the velocity of light. The configurations considered here are probably at least as relativistic as any stable astrophysical object in uniform rotation now thought to exist, but the phenomenon of an ergoregion appears in none of them and probably is absent in actual stars if magnetic viscosity or some other mechanism can induce rigid rotation

  4. Rotation of intramedullary alignment rods affects distal femoral cutting plane in total knee arthroplasty.

    Science.gov (United States)

    Maderbacher, Günther; Matussek, Jan; Keshmiri, Armin; Greimel, Felix; Baier, Clemens; Grifka, Joachim; Maderbacher, Hermann

    2018-02-17

    Intramedullary rods are widely used to align the distal femoral cut in total knee arthroplasty. We hypothesised that both coronal (varus/valgus) and sagittal (extension/flexion) cutting plane are affected by rotational changes of intramedullary femoral alignment guides. Distal femoral cuts using intramedullary alignment rods were simulated by means of a computer-aided engineering software in 4°, 6°, 8°, 10°, and 12° of valgus in relation to the femoral anatomical axis and 4° extension, neutral, as well as 4°, 8°, and 12° of flexion in relation to the femoral mechanical axis. This reflects the different angles between anatomical and mechanical axis in coronal and sagittal planes. To assess the influence of rotation of the alignment guide on the effective distal femoral cutting plane, all combinations were simulated with the rod gradually aligned from 40° of external to 40° of internal rotation. Rotational changes of the distal femoral alignment guides affect both the coronal and sagittal cutting planes. When alignment rods are intruded neutrally with regards to sagittal alignment, external rotation causes flexion, while internal rotation causes extension of the sagittal cutting plane. Simultaneously the coronal effect (valgus) decreases resulting in an increased varus of the cutting plane. However, when alignment rods are intruded in extension or flexion partly contradictory effects are observed. Generally the effect increases with the degree of valgus preset, rotation and flexion. As incorrect rotation of intramedullary alignment guides for distal femoral cuts causes significant cutting errors, exact rotational alignment is crucial. Coronal cutting errors in the distal femoral plane might result in overall leg malalignment, asymmetric extension gaps and subsequent sagittal cutting errors.

  5. Total body neutron activation analysis of calcium: calibration and normalisation

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, N S.J.; Eastell, R; Ferrington, C M; Simpson, J D; Strong, J A [Western General Hospital, Edinburgh (UK); Smith, M A; Tothill, P [Royal Infirmary, Edinburgh (UK)

    1982-05-01

    An irradiation system has been designed, using a neutron beam from a cyclotron, which optimises the uniformity of activation of calcium. Induced activity is measured in a scanning, shadow-shield whole-body counter. Calibration has been effected and reproducibility assessed with three different types of phantom. Corrections were derived for variations in body height, depth and fat thickness. The coefficient of variation for repeated measurements of an anthropomorphic phantom was 1.8% for an absorbed dose equivalent of 13 mSv (1.3 rem). Measurements of total body calcium in 40 normal adults were used to derive normalisation factors which predict the normal calcium in a subject of given size and age. The coefficient of variation of normalised calcium was 6.2% in men and 6.6% in women, with the demonstration of an annual loss of 1.5% after the menopause. The narrow range should make single measurements useful for diagnostic purposes.

  6. Risk management in radiotherapy: analysis for total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Banguero, Y., E-mail: ybanguero@cin.edu.uy [Universidad de la República, Montevideo (Uruguay); Píriz, G.; Guerrero, L.; Cardozo, L.; Quarneti, A. [Centro Hospital Pereira Rossell, Montevideo (Uruguay); Nader, A. [Autoridad Reguladora Nacional de Radioprotección, Montevideo (Uruguay)

    2017-07-01

    Introduction: Management of risk in any technique that is using radiation energy is very important to prevent incidents and accidents. Pretending evaluate the risk in the all process of Total Body Irradiation (TBI), this work present a risk matrix with different possible events than could occur. Methods: SEVRRA-R platform that run in windows is using to build a risk matrix separating the process of TBI in commissioning, prescription, planning and delivering dose. Any stage has a procedure with different errors associated. We build a matrix using all this information to evaluate the kind of risk we have in the technique. Results: It was obtained a template that describes in general the process of TBI with principles events, barriers and consequences. Conclusion: Analyzing the risk in any stage of the process in Total Body irradiation is a useful tool to understand the key points to work in safety for this technique. (author)

  7. Integral bounds for N-body total cross sections

    International Nuclear Information System (INIS)

    Osborn, T.A.; Bolle, D.

    1979-01-01

    We study the behavior of the total cross sections in the three- and N-body scattering problem. Working within the framework of the time-dependent two-Hilbert space scattering theory, we give a simple derivation of integral bounds for the total cross section for all processes initiated by the collision of two clusters. By combining the optical theorem with a trace identity derived by Jauch, Sinha, and Misra, we find, roughly speaking, that if the local pairwise interaction falls off faster than r -3 , then sigma/sub tot/(E) must decrease faster than E/sup -1/2/ at high energy. This conclusion is unchanged if one introduces a class of well-behaved three-body interactions

  8. Dose equivalent distributions in the AAEC total body nitrogen facility

    International Nuclear Information System (INIS)

    Allen, B.J.; Bailey, G.M.; McGregor, B.J.

    1985-01-01

    The incident neutron dose equivalent in the AAEC total body nitrogen facility is measured by a calibrated remmeter. Dose equivalent rates and distributions are calculated by Monte Carlo techniques which take account of the secondary neutron flux from the collimator. Experiment and calculation are found to be in satisfactory agreement. The effective dose equivalent per exposure is determined by weighting organ doses, and the potential detriment per exposure is calculated from ICRP risk factors

  9. Nuclear shape evolution starting from superdeformed state. Role of two-body collision and rotation

    International Nuclear Information System (INIS)

    Liu, Yu-xin; Sakata, Fumihiko

    1999-01-01

    With the nuclear density distribution being simulated by the Boltzmann Uehling-Uhlenbeck equation and Vlasov equation with several rotational frequencies, the time evolution of the quadrupole moment of nucleus 86 Zr starting with superdeformed shape is studied. The contribution of two-body collisions and the effects of collective rotation to the shape evolution is investigated. The numerical results indicate that the two-body collisions play a role of damping on the evolution from a superdeformed shape to a normal deformed one in a case without rotation. In a case of rotation with lower frequency, the two-body collisions accelerate the evolution process. A new role of the collective rotation to enhance the nuclear fission is proposed. (author)

  10. Atlas of total body radionuclide imaging. Volume I and II

    International Nuclear Information System (INIS)

    Fordham, E.W.; Ali, A.; Turner, D.A.; Charters, J.

    1982-01-01

    This two-volume work on total body imaging may well be regarded by future historians of nuclear medicine as representing the high points in the art of total body imaging in clinical nuclear medicine. With regard to information content and volume, it is the largest collection of well-interpreted, beautifully reproduced, total body images available to date. The primary goal of this atlas is to demonstrate patterns of abnormality in both typical and less typical variations. This goal is accomplished with many well-described examples of technical artifacts, of normal variants, of common and of rare diseases, and of pitfalls in interpretations. Volume I is entirely dedicated to skeletal imaging with Tc-99m labeled phosphates or phosphonates. The volume is divided into 22 chapters, which include chapters on methodology and instrumentation, chapters on the important bone diseases and other topics such as a treatise on false-negative and false-positive scans, and soft tissue and urinary tract abnormalities recognizable on bone scintigrams

  11. The motion of a compressible viscous fluid around rotating body

    Czech Academy of Sciences Publication Activity Database

    Kračmar, S.; Nečasová, Šárka; Novotný, A.

    2014-01-01

    Roč. 60, č. 1 (2014), s. 189-208 ISSN 0430-3202 R&D Projects: GA ČR(CZ) GAP201/11/1304 Institutional support: RVO:67985840 Keywords : compressible fluids * rotating fluids * Navier-Stokes equations Subject RIV: BA - General Mathematics http://link.springer.com/article/10.1007%2Fs11565-014-0212-5

  12. Feasibility study of helical tomotherapy for total body or total marrow irradiation

    International Nuclear Information System (INIS)

    Hui, Susanta K.; Kapatoes, Jeff; Fowler, Jack; Henderson, Douglas; Olivera, Gustavo; Manon, Rafael R.; Gerbi, Bruce; Mackie, T. R.; Welsh, James S.

    2005-01-01

    Total body radiation (TBI) has been used for many years as a preconditioning agent before bone marrow transplantation. Many side effects still plague its use. We investigated the planning and delivery of total body irradiation (TBI) and selective total marrow irradiation (TMI) and a reduced radiation dose to sensitive structures using image-guided helical tomotherapy. To assess the feasibility of using helical tomotherapy (A) we studied variations in pitch, field width, and modulation factor on total body and total marrow helical tomotherapy treatments. We varied these parameters to provide a uniform dose along with a treatment times similar to conventional TBI (15-30 min). (B) We also investigated limited (head, chest, and pelvis) megavoltage CT (MVCT) scanning for the dimensional pretreatment setup verification rather than total body MVCT scanning to shorten the overall treatment time per treatment fraction. (C) We placed thermoluminescent detectors (TLDs) inside a Rando phantom to measure the dose at seven anatomical sites, including the lungs. A simulated TBI treatment showed homogeneous dose coverage (±10%) to the whole body. Doses to the sensitive organs were reduced by 35%-70% of the target dose. TLD measurements on Rando showed an accurate dose delivery (±7%) to the target and critical organs. In the TMI study, the dose was delivered conformally to the bone marrow only. The TBI and TMI treatment delivery time was reduced (by 50%) by increasing the field width from 2.5 to 5.0 cm in the inferior-superior direction. A limited MVCT reduced the target localization time 60% compared to whole body MVCT. MVCT image-guided helical tomotherapy offers a novel method to deliver a precise, homogeneous radiation dose to the whole body target while reducing the dose significantly to all critical organs. A judicious selection of pitch, modulation factor, and field size is required to produce a homogeneous dose distribution along with an acceptable treatment time. In

  13. From Talking Heads to Communicating Bodies: Cybersemiotics and Total Communication

    Directory of Open Access Journals (Sweden)

    Ole Nedergaard Thomsen

    2010-03-01

    Full Text Available Current linguistics is biased towards considering as object of scientific study only verbal language, i.e., ordinary language whose basic entities are words, sentences, and texts. By having this focus, the crucial non-verbal semiotic contributions from acts of bodily communication are left out of consideration. On the face of it, this is a strange situation, because, phenomenologically, when observing a communicating dyad, what appears to the senses is a multimodal semiotic display–the interactants produce acts of total communication, the linguistic part of which has in fact to be disentangled from the integral semiotic behavior. That a human being should in the first place be conceptualized as a ‘talking head’, rather than a ‘communicating body’, stems from at least four historically interrelated fountains: ancient Greek philosophy with its emphasis on logos as meaning both rational mind and verbal language/speech as well as with its rejection of rhetoric (including body language; Cartesian dualistic rationalism where the body was the animal, mechanistic part of a human being, unworthy for the Geisteswissenschaften; Saussure’s formal structuralism with its defocusing of the individual’s performance, parole, and its high focus on societal langue; and Chomskyan linguistics with its neglect of actual, also bodily, performance, and its total focus on an ideal mental grammatical computational competence. With the recent philosophy (‘in the flesh’ of the ‘embodied mind’, time has now come for integrating the (linguistic head with the (other part of the communicating body and seeing communication as total communication of the whole body. This means that the communicating mind is no longer restricted to its ‘rational’ aspects but has to be conceived full-scale as integrating also all kinds of ‘irrational’ factors, like emotions and motivations. Another, no less important, implication of the above is that an individual

  14. Cost-Effectiveness of Reverse Total Shoulder Arthroplasty Versus Arthroscopic Rotator Cuff Repair for Symptomatic Large and Massive Rotator Cuff Tears.

    Science.gov (United States)

    Makhni, Eric C; Swart, Eric; Steinhaus, Michael E; Mather, Richard C; Levine, William N; Bach, Bernard R; Romeo, Anthony A; Verma, Nikhil N

    2016-09-01

    To compare the cost-effectiveness within the United States health care system of arthroscopic rotator cuff repair versus reverse total shoulder arthroplasty in patients with symptomatic large and massive rotator cuff tears without cuff-tear arthropathy. An expected-value decision analysis was constructed comparing the costs and outcomes of patients undergoing arthroscopic rotator cuff repair and reverse total shoulder arthroplasty for large and massive rotator cuff tears (and excluding cases of cuff-tear arthropathy). Comprehensive literature search provided input data to extrapolate costs and health utility states for these outcomes. The primary outcome assessed was that of incremental cost-effectiveness ratio (ICER) of reverse total shoulder arthroplasty versus rotator cuff repair. For the base case, both arthroscopic rotator cuff repair and reverse total shoulder were superior to nonoperative care, with an ICER of $15,500/quality-adjusted life year (QALY) and $37,400/QALY, respectively. Arthroscopic rotator cuff repair was dominant over primary reverse total shoulder arthroplasty, with lower costs and slightly improved clinical outcomes. Arthroscopic rotator cuff repair was the preferred strategy as long as the lifetime progression rate from retear to end-stage cuff-tear arthropathy was less than 89%. However, when the model was modified to account for worse outcomes when reverse shoulder arthroplasty was performed after a failed attempted rotator cuff repair, primary reverse total shoulder had superior outcomes with an ICER of $90,000/QALY. Arthroscopic rotator cuff repair-despite high rates of tendon retearing-for patients with large and massive rotator cuff tears may be a more cost-effective initial treatment strategy when compared with primary reverse total shoulder arthroplasty and when assuming no detrimental impact of previous surgery on outcomes after arthroplasty. Clinical judgment should still be prioritized when formulating treatment plans for these

  15. Efficiency of wave-driven rigid body rotation toroidal confinement

    Science.gov (United States)

    Rax, J. M.; Gueroult, R.; Fisch, N. J.

    2017-03-01

    The compensation of vertical drifts in toroidal magnetic fields through a wave-driven poloidal rotation is compared with compensation through the wave driven toroidal current generation to support the classical magnetic rotational transform. The advantages and drawbacks associated with the sustainment of a radial electric field are compared with those associated with the sustainment of a poloidal magnetic field both in terms of energy content and power dissipation. The energy content of a radial electric field is found to be smaller than the energy content of a poloidal magnetic field for a similar set of orbits. The wave driven radial electric field generation efficiency is similarly shown, at least in the limit of large aspect ratio, to be larger than the efficiency of wave-driven toroidal current generation.

  16. Flow visualization around a rotating body in a wind tunnel

    Science.gov (United States)

    Hiraki, K.; Zaitsu, D.; Yanaga, Y.; Kleine, H.

    2017-02-01

    The rotational behavior of capsule-shaped models is investigated in the transonic wind tunnel of JAXA. A special support is developed to allow the model to rotate around the pitch, yaw and roll axes. This 3-DOF free rotational mounting apparatus achieves the least frictional torque from the support and the instruments. Two types of capsule models are prepared, one is drag type (SPH model) and the other is lift type (HTV-R model). The developed mounting apparatus is used in the wind tunnel tests with these capsule models. In a flow of Mach 0.9, the SPH model exhibits oscillations in pitch and yaw, and it rolls half a turn during the test. Similarly, the HTV-R model exhibits pitch and yaw oscillations in a flow of Mach 0.5. Moreover, it rolls multiple times during the test. In order to investigate the flow field around the capsule, the combined technique of color schlieren and surface tufts is applied. This visualization clearly shows the flow reattachment on the back surface of a capsule, which is suspected to induce the rapid rolling motion.

  17. Computer-based anthropometrical system for total body irradiation.

    Science.gov (United States)

    Sánchez-Nieto, B; Sánchez-Doblado, F; Terrón, J A; Arráns, R; Errazquin, L

    1997-05-01

    For total body irradiation (TBI) dose calculation requirements, anatomical information about the whole body is needed. Despite the fact that video image grabbing techniques are used by some treatment planning systems for standard radiotherapy, there are no such systems designed to generate anatomical parameters for TBI planning. The paper describes an anthropometrical computerised system based on video image grabbing which was purpose-built to provide anatomical data for a PC-based TBI planning system. Using software, the system controls the acquisition and digitalisation of the images (external images of the patient in treatment position) and the measurement procedure itself (on the external images or the digital CT information). An ASCII file, readable by the TBI planning system, is generated to store the required parameters of the dose calculation points, i.e. depth, backscatter tissue thickness, thickness of inhomogeneity, off-axis distance (OAD) and source to skin distance (SSD).

  18. Equations of motion for free-flight systems of rotating-translating bodies

    International Nuclear Information System (INIS)

    Hodapp, A.E. Jr.

    1976-09-01

    General vector differential equations of motion are developed for a system of rotating-translating, unbalanced, constant mass bodies. Complete flexibility is provided in placement of the reference coordinates within the system of bodies and in placement of body fixed axes within each body. Example cases are presented to demonstrate the ease in reduction of these equations to the equations of motion for systems of interest

  19. Total body irradiation in hematopoietic stem cell transplantation

    Directory of Open Access Journals (Sweden)

    Fundagul Andic

    2014-06-01

    Full Text Available Total body irradiation is used in conjunction with chemotherapy as a conditioning regimen in the treatment of many disease such as leukemia, myelodysplastic syndrome, aplastic anemia, multiple myeloma and lymphoma prior to the hematopoetic stem cell transplantation. The main purposes of the hematopoetic stem cell transplantation are eradication of the recipient bone marrow and any residual cancer cells, creation of space in the receipient bone marrow for donor hematopoetic stem cells, and immunosuppression to prevent rejection of donor stem cells in the case of an allotransplant. [Archives Medical Review Journal 2014; 23(3.000: 398-410

  20. Treatment of neuroblastoma. Role of total Body Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Dini, G; Perin, G P; Franzone, P; Corvo, R; Scarpati, D

    1986-01-01

    Advanced neuroblastoma, scarcely responsive to conventional therapies, can take advantage of high dose chemio-radiotherapic treatment followed by bone marrow transplant. Nineteen young patients underwent an ablative chemotherapy with high dose Vincristine and Melphalan plus Total Body Irradiation in Genoa, Italy; all of them underwent autologus bone marrow transplantation. Fourteen children were in complete remission (CR), 5 had residual disease. Thirteen are alive after a median of 7 months following transplant; 9 are in CR; 4 have disease; 1 died for toxicity; 5 for relapse. The results seem to suggest that ablative therapy should be given to patients in CR. Toxicity was not remarkable mainly as far as TBI is concerned.

  1. Hepatic, renal, and total body galactose elimination in the pig

    DEFF Research Database (Denmark)

    Winkler, K; Henriksen, Jens Henrik Sahl; Tygstrup, N

    1993-01-01

    Galactose elimination capacity is used as a quantitative measure of liver function on the assumption that galactose elimination outside the liver is negligible or easily corrected for. The relationship between hepatic and extrahepatic removal of galactose was studied in anesthetized pigs during...... reabsorption (Tm 178 +/- 3.0 mumol/min, Km 3.8 +/- 0.9 mmol/l, n = 20). Metabolic conversion of galactose in the kidney was not demonstrable. At all concentrations studied (0.4-5.8 mmol/l), total galactose elimination from the body exceeded the sum of hepatic and renal elimination by approximately 100 mumol....../min, independent of the concentration. At blood concentrations usually used for clinical estimation of the galactose elimination capacity (approximately 4 mmol/l), hepatic removal in the pig accounted for 55% and renal removal for 30% of total removal; 15% of removal occurred in other organs. We conclude...

  2. Functional Outcomes and Predictors of Failure After Rotator Cuff Repair During Total Shoulder Arthroplasty.

    Science.gov (United States)

    Livesey, Michael; Horneff, John G; Sholder, Daniel; Lazarus, Mark; Williams, Gerald; Namdari, Surena

    2018-05-01

    A well-functioning rotator cuff is necessary for successful anatomic total shoulder arthroplasty (TSA). This study evaluated patients who underwent concomitant TSA and rotator cuff repair (RCR) for functional outcomes, revision rates, and predictors of poor results. Retrospective chart review was conducted to identify patients who underwent TSA and RCR. Demographic data, rotator cuff tear and RCR characteristics, range of motion, and radiographs were recorded. Minimum 2-year functional outcomes were obtained. Predictors of reoperation and/or poor clinical results were determined. Forty-five patients met inclusion criteria (22 high-grade partial-thickness and 23 full-thickness tears). Fourteen (31%) patients were labeled as having a poor result; 8 (18%) patients required reoperation. There was a significant difference between the acromiohumeral interval preoperatively and immediately postoperatively (P=.013). However, at maximum radiographic follow-up, the acromiohumeral interval was not significantly different from preoperative values (P=.86). Patients with a preoperative acromiohumeral interval of less than 8 mm had an increased rate of cuff-related reoperation (P=.003). Although concomitant TSA and RCR is a reasonable consideration, 31% of patients had a poor clinical result. An acromiohumeral interval of less than 8 mm was a predictor of cuff-related reoperation and may be an indication to consider reverse arthroplasty in the setting of joint arthrosis with a rotator cuff tear. [Orthopedics. 2018; 41(3):e334-e339.]. Copyright 2018, SLACK Incorporated.

  3. Estimation of total body water by bioelectrical impedance analysis

    International Nuclear Information System (INIS)

    Kushner, R.F.; Schoeller, D.A.

    1986-01-01

    Total body water (TBW) measured by bioelectrical impedance analysis (BIA) was directly compared with deuterium-isotope dilution in a total of 58 subjects. First, sex-specific and group equations were developed by multiple regression analysis in (10 each) obese and nonobese men and women. Height/resistive impedance was the most significant variable used to predict deuterium-dilution space (D2O-TBW) and, combined with weight, yielded R = 0.99 and SE of estimate = 1.75 L. Equations predicted D2O-TBW equally well for obese and nonobese subjects. Second, the equations were prospectively tested in a heterogeneous group of 6 males and 12 females. Sex-specific equations predicted D2O-TBW with good correlation coefficients (0.96 and 0.93), total error (2.34 and 2.89 L), and a small difference between mean predicted and measured D2O-TBW (-1.4 +/- 2.05 and -0.48 +/- 2.83 L). BIA predicts D2O-TBW more accurately than weight, height, and/or age. A larger population is required to validate the applicability of our equations

  4. A new method of body habitus correction for total body potassium measurements

    International Nuclear Information System (INIS)

    O'Hehir, S; Green, S; Beddoe, A H

    2006-01-01

    This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some components of the total measurement uncertainty which are difficult to quantify experimentally. A method is proposed for MCNP-assessed body habitus corrections based on a simple generic anthropomorphic model, scaled for individual height and weight. The use of this model increases patient comfort by reducing the need for comprehensive anthropomorphic measurements. The analysis shows that the total uncertainty in potassium weight determination by this whole body counting methodology for water-filled phantoms with a known amount of potassium is 2.7% (SD). The uncertainty in the method of body habitus correction (applicable also to phantom-based methods) is 1.5% (SD). It is concluded that this new strategy provides a sufficiently accurate model for routine clinical use

  5. A new method of body habitus correction for total body potassium measurements

    Energy Technology Data Exchange (ETDEWEB)

    O' Hehir, S [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom); Green, S [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom); Beddoe, A H [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom)

    2006-09-07

    This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some components of the total measurement uncertainty which are difficult to quantify experimentally. A method is proposed for MCNP-assessed body habitus corrections based on a simple generic anthropomorphic model, scaled for individual height and weight. The use of this model increases patient comfort by reducing the need for comprehensive anthropomorphic measurements. The analysis shows that the total uncertainty in potassium weight determination by this whole body counting methodology for water-filled phantoms with a known amount of potassium is 2.7% (SD). The uncertainty in the method of body habitus correction (applicable also to phantom-based methods) is 1.5% (SD). It is concluded that this new strategy provides a sufficiently accurate model for routine clinical use.

  6. Changes in body chemical composition with age measured by total-body neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Vaswani, A.; Zanzi, I.; Aloia, J.F.; Roginsky, M.S.; Ellis, K.J.

    1976-01-01

    Total-body levels of calcium and phosphorus (reflecting skeletal mass) and total-body levels of potassium (reflecting muscle mass) were measured by neutron activation analysis in 39 men and 40 women ages 30 to 90 yr. In order to intercompare the total body calcium (TBCa) values in a heterogeneous population, such as this, it was necessary to normalize the data for skeletal size. The normalization consisted of dividing the absolute calcium level by the predicted calcium level for each individual matched to a set of critical parameters. The parameter used in the computation of normal values were age, sex, muscle mass, i.e., total body potassium (TBK) and height. For the calcium data of the women, it was necessary to add an age correction factor after the age of 55 yr. The calcium ratio (mean ratio of the predicted to measured TBCa) in men was 1.000 +- 7.8 percent and in women 0.996 +- 7.1 percent. The TBCa of normal males and females can thus be predicted to +-13 percent (at the 90 percent confidence level). An exception to this was found in males (70 to 90 yr) who exhibited a mean calcium ratio greater than 1.13

  7. Mental rotation and the human body: Children's inflexible use of embodiment mirrors that of adults.

    Science.gov (United States)

    Krüger, Markus; Ebersbach, Mirjam

    2017-12-25

    Adults' mental rotation performance with body-like stimuli is enhanced if these stimuli are anatomically compatible with a human body, but decreased by anatomically incompatible stimuli. In this study, we investigated these effects for kindergartners and first-graders: When asked to mentally rotate cube configurations attached with human body parts in an anatomically compatible way, allowing for the projection of a human body, children performed better than with pure cube combinations. By contrast, when body parts were attached in an anatomically incompatible way, disallowing the projection of a human body, children performed worse than with pure combinations. This experiment is of specific interest against the background of two different theoretical approaches concerning imagery and the motor system in development: One approach assumes an increasing integration of motor processes and imagery over time that enables older children and adults to requisition motor resources for imagery processes, while the other postulates that imagery stems from early sensorimotor processes in the first place, and is disentangled from it over time. The finding that children of the two age groups tested show exactly the same effects as adults when mentally rotating anatomically compatible and incompatible stimuli is interpreted in favour of the latter approach. Statement of contribution What is already known on this subject? In mental rotation, adults perform better when rotating anatomically possible stimuli as compared to rotating standard cube combinations. Performance is worse when rotating anatomically impossible stimuli. What does this study add? The present study shows that children's mental transformations mirror those of adults in these respects. In case of the anatomically impossible stimuli, this highlights an inflexible use of embodiment in both age groups. This is in line with the Piagetian assumption of imagery being based on sensorimotor processes. © 2017 The British

  8. Bromide space, total body water, and sick cell syndrome

    International Nuclear Information System (INIS)

    Schober, O.; Hundeshagen, H.; Lehr, L.

    1982-01-01

    Displacements of the bromide space (Br-82-C, as a marker for the extracellular fluid compartment) are caused by an enhanced anatomical space and/or increased permeability of cells to bromide. The ratio Br-82-C: total body water (TBW) was evaluated to be 0.83 +- 0.17 in critically ill patients (n = 38) compared with the normal value of 0.46 +- 0.04 (n = 10). Because of normal TBW in critically ill patients (TBW = 505 +- 68 ml/kg), an increased bromide penetration into cells seems to be responsible for the enlarged ratio Br-82-C: TBW. Taking into consideration measurements in patients with malabsorption (Br-82-C: TBW = 0.56 +- 0.13; n = 13) and carcinoma of the rectum and colon (Br-82-C: TBW = 0.66 +- 0.24; n = 18) we think that the bromide space is a good measurement of the effective extracellular water. (orig.)

  9. Numerical Simulation and Experiment of a Lifting Body with Leading-Edge Rotating Cylinder

    OpenAIRE

    A. Badarudin; C. S. Oon; S. N. Kazi; N. Nik-Ghazali; Y. J. Lee; W. T. Chong

    2013-01-01

    An experimental and simulation flight test has been carried out to evaluate the longitudinal gliding characteristics of a lifting body with blunted half-cone geometry. The novelty here is the lifting body's pitch control mechanism, which consists of a pair of leading-edge rotating cylinders. Flight simulation uses aerodynamic data from computational fluid dynamics supported by wind-tunnel test. Flight test consists of releasing an aluminum lifting body model from a moving vehicle at the appro...

  10. In vivo dosimetry with silicon diodes in total body irradiation

    International Nuclear Information System (INIS)

    Oliveira, F.F.; Amaral, L.L.; Costa, A.M.; Netto, T.G.

    2014-01-01

    The aim of this work is the characterization and application of silicon diode detectors for in vivo dosimetry in total body irradiation (TBI) treatments. It was evaluated the diode response with temperature, dose rate, gantry angulations and field size. A maximum response variation of 2.2% was obtained for temperature dependence. The response variation for dose rate and angular was within 1.2%. For field size dependence, the detector response increased with field until reach a saturation region, where no more primary radiation beam contributes for dose. The calibration was performed in a TBI setup. Different lateral thicknesses from one patient were simulated and then the calibration factors were determined by means of maximum depth dose readings. Subsequent to calibration, in vivo dosimetry measurements were performed. The response difference between diode readings and the prescribed dose for all treatments was below 4%. This difference is in agreement as recommended by the International Commission on Radiation Units and Measurements (ICRU), which is ±5%. The present work to test the applicability of a silicon diode dosimetry system for performing in vivo dose measurements in TBI techniques presented good results. These measurements demonstrated the value of diode dosimetry as a treatment verification method and its applicability as a part of a quality assurance program in TBI treatments. - Highlights: ► Characterization of a silicon diode dosimetry system. ► Application of the diodes for in vivo dosimetry in total body irradiation treatments. ► Implementation of in vivo dosimetry as a part of a quality assurance program in radiotherapy

  11. Vestibular-somatosensory interactions: effects of passive whole-body rotation on somatosensory detection.

    Directory of Open Access Journals (Sweden)

    Elisa Raffaella Ferrè

    Full Text Available Vestibular signals are strongly integrated with information from several other sensory modalities. For example, vestibular stimulation was reported to improve tactile detection. However, this improvement could reflect either a multimodal interaction or an indirect interaction driven by vestibular effects on spatial attention and orienting. Here we investigate whether natural vestibular activation induced by passive whole-body rotation influences tactile detection. In particular, we assessed the ability to detect faint tactile stimuli to the fingertips of the left and right hand during spatially congruent or incongruent rotations. We found that passive whole-body rotations significantly enhanced sensitivity to faint shocks, without affecting response bias. Critically, this enhancement of somatosensory sensitivity did not depend on the spatial congruency between the direction of rotation and the hand stimulated. Thus, our results support a multimodal interaction, likely in brain areas receiving both vestibular and somatosensory signals.

  12. Biochemical and hematological indicators in model of total body irradiation

    International Nuclear Information System (INIS)

    Dubner, D; Gisone, P.; Perez, M.R.; Barboza, M.; Luchetta, P.; Longoni, H.; Sorrentino, M.; Robison, A.

    1998-01-01

    With the purpose of evaluating the applicability of several biological indicators in accidental overexposures a study was carried out in 20 patients undergoing therapeutical total body irradiation (TBI). The following parameters were evaluated: a) Oxidative stress indicators: erythrocyte superoxide dismutase (SOD) and catalase activity (CAT), lipo peroxyde levels (TBARS) and total plasma antioxidant activity (TAA). b) Haematological indicators: reticulocyte maturity index (RMI) and charges in lymphocyte subpopulations. Non significant changes in SOD and CAT activity were observed. Significant higher TBARS levels were found in patients with unfavorable post-BTM course without any significant correlation with TAA. RMI decreased early and dropped to zero in most of the patients and rose several days prior to reticulocyte, neutrophils and platelets counts. A significant decrease in absolute counts of all lymphocyte subpopulations was observed during TBI, particularly for B lymphocytes. A subpopulation of natural killer (NK) cells (CD16+/ CD 56 +) showed a relative higher radioresistance. Cytotoxic activity was significantly decreased after TBI. These data suggest that TBARS could provide an useful evolutive indicator in accidental over exposure d patients and RMI is an early indicator of bone marrow recovery after radioinduced aplasia. The implications of the different radiosensitivities within the NK subsets remains unanswered. (author) [es

  13. Postural Effects on the Mental Rotation of Body-Related Pictures: An fMRI Study

    Directory of Open Access Journals (Sweden)

    Fangbing Qu

    2018-05-01

    Full Text Available This study investigated the embodied effects involved in the mental rotation of pictures of body parts (hands and feet. Blood oxygen level-dependent (BOLD signals were collected from 18 healthy volunteers who performed mental rotation tasks of rotated drawings of hands under different arm postures. Congruent drawings of hands (those congruent with left-hand posture evoked stronger activation in the left supplementary motor area (SMA, left precentral gyrus, and left superior parietal lobule (SPL than did incongruent drawings of hands. Congruent drawings of hands (those congruent with right-hand posture evoked significant activation in the left inferior parietal lobule (IPL, right SMA, bilateral middle frontal gyrus (MFG, left inferior frontal gyrus (IFG, and bilateral superior frontal gyrus (SFG compared to that evoked by the incongruent drawings of hands. Similar methodology was implemented with drawings of feet. However, no significant differences in brain activation were observed between congruent and incongruent drawings of feet. This finding suggests that body posture influences body part-related mental rotation in an effector-specific manner. A direct comparison between the medially and laterally rotated drawings revealed activation in the right IPL, left precentral gyrus, bilateral IFG, and bilateral SFG. These results suggest that biomechanical constraints affect the cognitive process of mental rotation.

  14. Patterns of patient specific dosimetry in total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Akino, Yuichi [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, Indiana 46202 (United States); Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Osaka 565-0871 (Japan); McMullen, Kevin P.; Das, Indra J. [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, Indiana 46202 (United States)

    2013-04-15

    Purpose: Total body irradiation (TBI) has been used for bone marrow transplant for hematologic and immune deficiency conditions. The goal of TBI is to deliver a homogeneous dose to the entire body, with a generally accepted range of dose uniformity being within {+-}10% of the prescribed dose. The moving table technique for TBI could make dose uniform in whole body by adjusting couch speed. However, it is difficult to accurately estimate the actual dose by calculation and hence in vivo dosimetry (IVD) is routinely performed. Here, the authors present patterns of patient-specific IVD in 161 TBI patients treated at our institution. Methods: Cobalt-60 teletherapy unit (Model C9 Cobalt-60 teletherapy unit, Picker X-ray Corporation) with customized moving bed (SITI Industrial Products, Inc., Fishers, IN) were used for TBI treatment. During treatment, OneDose{sup TM} (Sicel Technology, NC) Metal Oxide-silicon Semiconductor Field Effect Transistor detectors were placed at patient body surface; both entrance and exit side of the beam at patient head, neck, mediastinum, umbilicus, and knee to estimate midplane dose. When large differences (>10%) between the prescribed and measured dose were observed, dose delivery was corrected for subsequent fractions by the adjustment of couch speed and/or bolus placement. Under IRB exempt status, the authors retrospectively analyzed the treatment records of 161 patients who received TBI treatment between 2006 and 2011. Results: Across the entire cohort, the median {+-} SD (range) percent variance between calculated and measured dose for head, neck, mediastinum, umbilicus, and knee was -2.3 {+-} 10.2% (-66.2 to +35.3), 1.1 {+-} 11.5% (-62.2 to +40.3), -1.9 {+-} 9.5% (-66.4 to +46.6), -1.1 {+-} 7.2% (-35.2 to +42.9), and 3.4 {+-} 12.2% (-47.9 to +108.5), respectively. More than half of treatments were within {+-}10% of the prescribed dose for all anatomical regions. For 80% of treatments (10%-90%), dose at the umbilicus was within {+-}10

  15. Mobile-bearing total knee arthroplasty: a full traumatic rotation of 180°.

    Science.gov (United States)

    Sudanese, Alessandra; Castiello, Emanuela; Affatato, Saverio

    2013-06-25

    From February 2008 to September 2012 we implanted 204 mobile-bearing knee prostheses in 192 patients. All the prostheses were cemented (both femoral and tibial components), and the patella was not replaced. Only one early complication of the implants (1/204 = 0.004%) occurred after a traumatic event as a full 180° rotation of the mobile-bearing polyethylene insert. A 78-year-old woman presented with swelling and severe pain at her right knee. This traumatic event was the only case among our mobile-bearing insert patients. 
The failed polyethylene inserts were retrieved and studied using a scanning electron microscope (SEM, ZEISS EVO 50 EP, Cambridge, UK) operating at 20 kV. 
Scratching and pitting were found on the UHMWPE insert perpendicular to the machining tracks for the concave surface. SEM micrographs of the insert showed burnishing on the concave surfaces and longitudinal scratches were clearly detectable and well-marked on the analyzed surfaces. 
A traumatic, fully rotating, polyethylene insert is rare and our case is the first report describing a traumatic event with a complete 180 degree rotation mobile-bearing in a total knee prosthesis. 
In the literature few reports discuss clinical outcomes after total knee arthroplasty in patients with Parkinson's disease and they cite mixed results. However, some authors suggest that posterior-stabilized and cruciate-retaining TKA should work well while others prefer cruciate-retaining, condylar constrained kinetics, or hinged devices. Although we did not implant a posterior-stabilized mobile-bearing total knee prosthesis or a constrained prosthesis, we obtained good clinical and radiological results at the 2-year followup.

  16. Frame-dragging effect in the field of non rotating body due to unit gravimagnetic moment

    Science.gov (United States)

    Deriglazov, Alexei A.; Ramírez, Walberto Guzmán

    2018-04-01

    Nonminimal spin-gravity interaction through unit gravimagnetic moment leads to modified Mathisson-Papapetrou-Tulczyjew-Dixon equations with improved behavior in the ultrarelativistic limit. We present exact Hamiltonian of the resulting theory and compute an effective 1/c2-Hamiltonian and leading post-Newtonian corrections to the trajectory and spin. Gravimagnetic moment causes the same precession of spin S as a fictitious rotation of the central body with angular momentum J = M/m S. So the modified equations imply a number of qualitatively new effects, that could be used to test experimentally, whether a rotating body in general relativity has null or unit gravimagnetic moment.

  17. Endocrine dysfunction after total body irradiation and bone marrow transplantation

    International Nuclear Information System (INIS)

    Feyer, P.; Titlbach, O.; Hoffmann, F.A.; Kubel, M.; Helbig, W.; Leipzig Univ.

    1989-01-01

    Data regarding changes of endocrine parameters after total body irradiation (TBI) and bone marrow transplantation (BMT) are described. Endocrine glands are usually resistant to irradiation under morphological aspects. But new methods of determination and sensitive tests were developed in the last few years. Now it is possible to detect already small functional changes. Endocrine studies in the course of the disease were followed serially in 16 patients with TBI and BMT. Pretransplant conditioning consisted of single-dose irradiation combined with a high-dose, short-term chemotherapy. Reactions of the endocrine system showed a defined temporary order. Changes of ACTH and cortisol were in the beginning. The pituitary-adrenal cortex system responds in a different way. The pituitary-thyroid system develops a short-term 'low-T 3 -syndrome' reflecting the extreme stress of the organism. At the same time we obtained an increase of thyroxine. Testosterone and luteotropic hormone, the sexual steroids showed levels representing a primary gonadal insufficiency. The studies in the posttransplant period yielded a return to the normal range at most of the hormonal levels with the exception of the sexual steroids. Sterility is one of the late effects of TBI. A tendency towards hypothyroidism could be noticed in some cases being only subclinical forms. Reasons and possible therapy are discussed. (author)

  18. Total body irradiation for myasthenia gravis with thymoma: case report

    International Nuclear Information System (INIS)

    Kang, Ki Mun; Choi, Ihl Bohng; Kim, In Ah

    1999-01-01

    Myasthenia Gravis (MG) is relatively rare occuring as one of important autoimmune disease to affect neuromuscular junction. This study was clinically to evaluate total body irradiation (TBI) against two patients including 33-year and 39-year females for chronic MG with thymoma who hospitalized in the St. Mary's Hospital, Catholic University since 1994 as well as who showed no response by thymectomy, immunotherapy and hormonal therapy. TBI designed by the dose of 150-180 cGy consisting of 10 cGy per fraction, three times a week, for 5-6 weeks using linear accelerator of 6 MV. During the treatment of TBI, they did complain acute side effect such as vomiting and also appear improved physical condition from 4-6 weeks after TBI. Through the follow-up period of 18 or 42 months after TBI, they did not have any symptomatic recurrence. Consequently, the results suggest that TBI can be used as an alternative tool for the patients concurrently for MG with thymoma who had been refractory to various conventional therapies like thymectomy, immunotherapy and hormonal therapy

  19. Positioning variations of the lungs shields during total body irradiation

    International Nuclear Information System (INIS)

    Costa, A.; Marcie, S.; Boulabeiz, A.; Lagrange, J.L.

    1995-01-01

    During total body irradiation, the patient is entirely exposed to radiation and the dose to lungs have to be limited. Personalized shields are make and set between the source and the patient, in front of lungs. The patient and the shields set up are checked before the treatment session with radiographs. Verification films are performed during the treatment sessions with anterior and posterior beams. During the treatment session, the patient may move and his relative positioning can change. Also, for each daily session treatment, his positioning could be different. One way to determine position discrepancies of the shields lungs is to analyse verification films. A study has been achieved comparing positions of lungs and shields edges in digitised simulator and digitised verification images. Discrepancies on distance and angle between similar anatomical landmarks in both images are determined by applying a least squares minimisation approach. In this study, which concerns 29 patients, distance discrepancies are founded from 1,5 to 12,6 mm for the anterior beams and from 1,8 to 15,3 mm for the posterior beams. Angle discrepancies are founded from 0 to 2 degrees

  20. Total body irradiation for myasthenia gravis with thymoma: case report

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ki Mun; Choi, Ihl Bohng; Kim, In Ah [College of Medicine, Catholic Univ., Seoul (Korea, Republic of)

    1999-06-01

    Myasthenia Gravis (MG) is relatively rare occuring as one of important autoimmune disease to affect neuromuscular junction. This study was clinically to evaluate total body irradiation (TBI) against two patients including 33-year and 39-year females for chronic MG with thymoma who hospitalized in the St. Mary's Hospital, Catholic University since 1994 as well as who showed no response by thymectomy, immunotherapy and hormonal therapy. TBI designed by the dose of 150-180 cGy consisting of 10 cGy per fraction, three times a week, for 5-6 weeks using linear accelerator of 6 MV. During the treatment of TBI, they did complain acute side effect such as vomiting and also appear improved physical condition from 4-6 weeks after TBI. Through the follow-up period of 18 or 42 months after TBI, they did not have any symptomatic recurrence. Consequently, the results suggest that TBI can be used as an alternative tool for the patients concurrently for MG with thymoma who had been refractory to various conventional therapies like thymectomy, immunotherapy and hormonal therapy.

  1. Secondary radiation dose during high-energy total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Janiszewska, M.; Raczkowski, M. [Lower Silesian Oncology Center, Medical Physics Department, Wroclaw (Poland); Polaczek-Grelik, K. [University of Silesia, Medical Physics Department, Katowice (Poland); Szafron, B.; Konefal, A.; Zipper, W. [University of Silesia, Department of Nuclear Physics and Its Applications, Katowice (Poland)

    2014-05-15

    The goal of this work was to assess the additional dose from secondary neutrons and γ-rays generated during total body irradiation (TBI) using a medical linac X-ray beam. Nuclear reactions that occur in the accelerator construction during emission of high-energy beams in teleradiotherapy are the source of secondary radiation. Induced activity is dependent on the half-lives of the generated radionuclides, whereas neutron flux accompanies the treatment process only. The TBI procedure using a 18 MV beam (Clinac 2100) was considered. Lateral and anterior-posterior/posterior-anterior fractions were investigated during delivery of 2 Gy of therapeutic dose. Neutron and photon flux densities were measured using neutron activation analysis (NAA) and semiconductor spectrometry. The secondary dose was estimated applying the fluence-to-dose conversion coefficients. The main contribution to the secondary dose is associated with fast neutrons. The main sources of γ-radiation are the following: {sup 56}Mn in the stainless steel and {sup 187}W of the collimation system as well as positron emitters, activated via (n,γ) and (γ,n) processes, respectively. In addition to 12 Gy of therapeutic dose, the patient could receive 57.43 mSv in the studied conditions, including 4.63 μSv from activated radionuclides. Neutron dose is mainly influenced by the time of beam emission. However, it is moderated by long source-surface distances (SSD) and application of plexiglass plates covering the patient body during treatment. Secondary radiation gives the whole body a dose, which should be taken into consideration especially when one fraction of irradiation does not cover the whole body at once. (orig.) [German] Die zusaetzliche Dosis durch sekundaere Neutronen- und γ-Strahlung waehrend der Ganzkoerperbestrahlung mit Roentgenstrahlung aus medizinischen Linearbeschleunigern wurde abgeschaetzt. Bei der Emission hochenergetischer Strahlen zur Teletherapie finden hauptsaechlich im Beschleuniger

  2. Total lymphoid irradiation and total body irradiation for allogeneic bone marrow transplantation in aplastic anemia

    Energy Technology Data Exchange (ETDEWEB)

    Kurisu, Koichi; Hishikawa, Yoshio; Taniguchi, Midori; Kamikonya, Norihiko; Miura, Takashi; Kanamaru, Akihisa; Kakishita, Eizo; Kai, Shunro; Hara, Hiroshi (Hyogo Coll. of Medicine, Nishinomiya (Japan))

    Between April 1980 and June 1989, 15 patients with severe aplastic anemia (SAA) were treated at Hyogo College of Medicine with bone marrow transplantation (BMT) after preparation consisting of cyclophosphamide (CY) and total lymphoid irradiation (TLI) or total body irradiation (TBI) for the purpose of reducing the incidence of graft rejection. All patients had initial evidence of engraftment after the first transplantation except for one patient who died of heart failure due to CY on the third day after transplantation and could not be evaluated for engraftment. Rejection later occurred in four of these 14 patients, who then underwent successful regrafting. One of these four patients, who was conditioned with CY alone at the first grafting, underwent successful regrafting after a conditioning regimen of CY and TBI. In the other three patients, irradiation was performed twice as the conditioning regimen. Thus, 14 of 15 patients underwent successful BMT and are alive with restored hematopoietic function. From the above results, the combination of TLI or TBI and CY was considered to be very useful as a conditioning regimen for BMT in patients with SAA. (author).

  3. Rates and timing of vertical-axis block rotations across the central Sierra Nevada-Walker Lane transition in the Bodie Hills, California/Nevada

    Science.gov (United States)

    Rood, Dylan H.; Burbank, Douglas W.; Herman, Scott W.; Bogue, Scott

    2011-10-01

    We use paleomagnetic data from Tertiary volcanic rocks to address the rates and timing of vertical-axis block rotations across the central Sierra Nevada-Walker Lane transition in the Bodie Hills, California/Nevada. Samples from the Upper Miocene (˜9 Ma) Eureka Valley Tuff suggest clockwise vertical-axis block rotations between NE-striking left-lateral faults in the Bridgeport and Mono Basins. Results in the Bodie Hills suggest clockwise rotations (R ± ΔR, 95% confidence limits) of 74 ± 8° since Early to Middle Miocene (˜12-20 Ma), 42 ± 11° since Late Miocene (˜8-9 Ma), and 14 ± 10° since Pliocene (˜3 Ma) time with no detectable northward translation. The data are compatible with a relatively steady rotation rate of 5 ± 2° Ma-1 (2σ) since the Middle Miocene over the three examined timescales. The average rotation rates have probably not varied by more than a factor of two over time spans equal to half of the total time interval. Our paleomagnetic data suggest that block rotations in the region of the Mina Deflection began prior to Late Miocene time (˜9 Ma), and perhaps since the Middle Miocene if rotation rates were relatively constant. Block rotation in the Bodie Hills is similar in age and long-term average rate to rotations in the Transverse Ranges of southern California associated with early transtensional dextral shear deformation. We speculate that the age of rotations in the Bodie Hills indicates dextral shear and strain accommodation within the central Walker Lane Belt resulting from coupling of the Pacific and North America plates.

  4. A conservative quaternion-based time integration algorithm for rigid body rotations with implicit constraints

    DEFF Research Database (Denmark)

    Nielsen, Martin Bjerre; Krenk, Steen

    2012-01-01

    A conservative time integration algorithm for rigid body rotations is presented in a purely algebraic form in terms of the four quaternions components and the four conjugate momentum variables via Hamilton’s equations. The introduction of an extended mass matrix leads to a symmetric set of eight...

  5. Design and characteristics of a 4 MV total body irradiator

    International Nuclear Information System (INIS)

    Lutz, W.R.; Chin, L.M.

    1988-01-01

    A facility for total body X-ray irradiation (TBI) has been built using two 4 MV linear accelerators, one mounted under the ceiling, the other in a floor-pit. The distance between the two sources is 410 cm to produce a field size of 200 cm x 75 cm in the midplane. This field covers the patient, lying supine on a stretcher halfway between the sources. Components from commercially available accelerators were used. Special beam hardening and flattening filters were built to achieve acceptable dose profiles in the large field. The primary collimator was modified to produce a 235 cm x 92 cm field at 205 cm from the source, while movable focused collimators were designed to define fields up to 220 cm x 80 cm. Because of the wide beams, large rectangular parallel-plate ionization chambers were built to serve as beam monitors. The dose rate at 205 cm distance from the sources can be set between 5 and 80 cGy/min, each machine contributing half. The dosimetric characteristics are practically the same for both units. The per cent depth dose for the TBI beams is 76% at a source-surface distance of 195 cm. The half value layer decreases by 12% from the centre to near the edge of the beam. Owing to the large field size, the surface dose for the TBI beams is about 80% of the dose at 1 cm depth. The dose delivery has been verified to be within 2% of the calculated value at the reference point in a homogeneous water humanoid phantom. Measurements indicate that lung doses can be predicted by the ratio-of-TMR (tissue-to-maximum ratio) method with acceptable accuracy. Lead sheets are used as attenuators to prevent excessive lung doses. (author). 7 refs, 7 figs

  6. 'Mini' total body irradiation and allogeneic bone marrow transplantation

    International Nuclear Information System (INIS)

    Gocheva, L.; Sergieva, K.; Koleva, I.; Avramova, V.; Vassileva, V.; Georgieva, S.; Sultanov, B.

    2006-01-01

    Full text: The total body irradiation (TBI) combined with intensive chemotherapy plays an important role in the preparation of patients for bone marrow transplantation (BMT). The first autologous BMT in Bulgaria was performed in 1997 in the Specialized Pediatric Hospital for Active Treatment (SPHAT) of oncohematological diseases. The first TBI, followed by allogeneic BMT, was carried out in 2002 in the 'Queen Giovanna' University Hospital, after which its routine application as a basic form of large field radiotherapy and a main stage of the conditioning regimen for BMT was started. Fourteen allogeneic BMTs including TBI as a basic conditioning regimen have been performed till May 2006. The objective of the present report is to present the first clinical observations in the Bulgarian oncological practice on 'mini' TBI followed by allogeneic blood stem cell transplantation. During the period October 2005 - May 2006, 'mini' TBI followed by allogeneic BMT was carried out for two patients of the age 43 and 50 years. The diagnosis of both patients was acute non-lymphoblastic leukemia, in the remission stage, after one relapse, respectively. Intensive preceding chemotherapy was applied for both patients. A conditioning regimen was applied including the fludarabine purine analogue (3 x 30 mg/m 2 ) and 200 cGy TBI. It was followed by transplantation of allogeneic cell concentrate containing 2.5 x10 6 /kg CD34+ and 4.0 x10 6 /kg CD34+ blood stem cells of partially compatible family donors (a sister and a son), which were tolerable for the patients without complications. Cyclosporine and mycophelonate mofetile were applied as post-transplantation treatment. Active antibiotic, antiviral, symptomatic and substituting therapy, as well as GvHD prophylaxis was applied for both patients. Good clinical tolerance was recorded for the applied low dose conditioning regimen. The patients were discharged within 30 days in good general condition and stable draft action, with

  7. Antihysteresis of perceived longitudinal body axis during continuous quasi-static whole-body rotation in the earth-vertical roll plane.

    Science.gov (United States)

    Tatalias, M; Bockisch, C J; Bertolini, G; Straumann, D; Palla, A

    2011-03-01

    Estimation of subjective whole-body tilt in stationary roll positions after rapid rotations shows hysteresis. We asked whether this phenomenon is also present during continuous quasi-static whole-body rotation and whether gravitational cues are a major contributing factor. Using a motorized turntable, 8 healthy subjects were rotated continuously about the earth-horizontal naso-occipital axis (earth-vertical roll plane) and the earth-vertical naso-occipital axis (earth-horizontal roll plane). In both planes, three full constant velocity rotations (2°/s) were completed in clockwise and counterclockwise directions (acceleration = 0.05°/s(2), velocity plateau reached after 40 s). Subjects adjusted a visual line along the perceived longitudinal body axis (pLBA) every 2 s. pLBA deviation from the longitudinal body axis was plotted as a function of whole-body roll position, and a sine function was fitted. At identical whole-body earth-vertical roll plane positions, pLBA differed depending on whether the position was reached by a rotation from upright or by passing through upside down. After the first 360° rotation, pLBA at upright whole-body position deviated significantly in the direction of rotation relative to pLBA prior to rotation initiation. This deviation remained unchanged after subsequent full rotations. In contrast, earth-horizontal roll plane rotations resulted in similar pLBA before and after each rotation cycle. We conclude that the deviation of pLBA in the direction of rotation during quasi-static earth-vertical roll plane rotations reflects static antihysteresis and might be a consequence of the known static hysteresis of ocular counterroll: a visual line that is perceived that earth-vertical is expected to be antihysteretic, if ocular torsion is hysteretic.

  8. Student understanding of the application of Newton's second law to rotating rigid bodies

    Science.gov (United States)

    Close, Hunter G.; Gomez, Luanna S.; Heron, Paula R. L.

    2013-06-01

    We report on an investigation of student understanding of rigid body dynamics in which we asked students in introductory calculus-based physics to compare the translational motions of identical rigid bodies subject to forces that differed only in the point of contact at which they were applied. There was a widespread tendency to claim that forces that cause rotational motion have a diminished effect on translational motion. A series of related problems was developed to examine whether similar errors would be made in other contexts, and interviews were conducted to probe student thinking in greater depth. In this paper, we describe the results of our investigation and also describe a series of different interventions that culminated in the development of a tutorial that improves student ability to apply Newton's second law to rotating rigid bodies.

  9. Marrow toxicity of fractionated vs. single dose total body irradiation is identical in a canine model

    International Nuclear Information System (INIS)

    Storb, R.; Raff, R.F.; Graham, T.; Appelbaum, F.R.; Deeg, H.J.; Schuening, F.G.; Shulman, H.; Pepe, M.

    1993-01-01

    The authors explored in dogs the marrow toxicity of single dose total body irradiation delivered from two opposing 60 Co sources at a rate of 10 cGy/min and compared results to those seen with total body irradiation administered in 100 cGy fractions with minimum interfraction intervals of 6 hr. Dogs were not given marrow transplants. They found that 200 cGy single dose total body irradiation was sublethal, with 12 of 13 dogs showing hematopoietic recovery and survival. Seven of 21 dogs given 300 cGy single dose total body irradiation survived compared to 6 of 10 dogs given 300 cGy fractionated total body irradiation. One of 28 dogs given 400 cGy single dose total body irradiation survived compared to none of six given fractionated radiation. With granulocyte colony stimulating factor (GCSF) administered from day 0-21 after 400 cGy total body irradiation, most dogs survived with hematological recovery. Because of the almost uniform success with GCSF after 400 cGy single dose total body irradiation, a study of GCSF after 400 cGy fractionated total body irradiation was deemed not to be informative and, thus, not carried out. Additional comparisons between single dose and fractionated total body irradiation were carried out with GCSF administered after 500 and 600 cGy of total body irradiation. As with lower doses of total body irradiation, no significant survival differences were seen between the two modes of total body irradiation, and only 3 of 26 dogs studied survived with complete hematological recovery. Overall, therefore, survival among dogs given single dose total body irradiation was not different from that of dogs given fractionated total body irradiation (p = .67). Similarly, the slopes of the postirradiation declines of granulocyte and platelet counts and the rates of their recovery in surviving dogs given equal total doses of single versus fractionated total body irradiation were indistinguishable. 24 refs., 3 figs., 2 tabs

  10. Evaluation of body composition and nitrogen content of renal patients on chronic dialysis as determined by total body neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Brennan, B.L.; Yasumura, S.; Vartsky, D.; Vaswani, A.N.; Ellis, K.J.

    1983-01-01

    Total body protein (nitrogen), body cell mass (potassium), fat, and water were measured in 15 renal patients on maintenance hemodialysis (MHD). Total body nitrogen was measured by means of prompt γ neutron activation analysis; total body water was determined with tritium labeled water; total body potassium was measured by whole body counting. The extracellular water was determined by a technique utilizing the measurement of total body chloride and plasma chloride. When compared with corresponding values of a control group of the same age, sex, and height, the protein content, body cell mass, and total body fat of the MHD patients were within the normal range. The only significant change was an increase in the extracellular water/body cell mass ratio in the male MHD patients compared to the control. The lack of significant difference of the nitrogen values of the MHD patients compared to matched controls suggests that dialysis minimizes any residual effects of uremic toxicity or protein-calorie malnutrition. These findings further suggest that there is a need to reevaluate the traditional anthropometric and biochemical standards of nutritional status for MHD patients. It was concluded that it is particularly important to measure protein stores of MHD patients with low protein intake to ascertain nutritional status. Finally, in vivo measurement of total body nitrogen and potassium for determination of body composition provides a simple, direct, and accurate assessment of the nutritional status of MHD patients

  11. Dissociating object-based from egocentric transformations in mental body rotation: effect of stimuli size.

    Science.gov (United States)

    Habacha, Hamdi; Moreau, David; Jarraya, Mohamed; Lejeune-Poutrain, Laure; Molinaro, Corinne

    2018-01-01

    The effect of stimuli size on the mental rotation of abstract objects has been extensively investigated, yet its effect on the mental rotation of bodily stimuli remains largely unexplored. Depending on the experimental design, mentally rotating bodily stimuli can elicit object-based transformations, relying mainly on visual processes, or egocentric transformations, which typically involve embodied motor processes. The present study included two mental body rotation tasks requiring either a same-different or a laterality judgment, designed to elicit object-based or egocentric transformations, respectively. Our findings revealed shorter response times for large-sized stimuli than for small-sized stimuli only for greater angular disparities, suggesting that the more unfamiliar the orientations of the bodily stimuli, the more stimuli size affected mental processing. Importantly, when comparing size transformation times, results revealed different patterns of size transformation times as a function of angular disparity between object-based and egocentric transformations. This indicates that mental size transformation and mental rotation proceed differently depending on the mental rotation strategy used. These findings are discussed with respect to the different spatial manipulations involved during object-based and egocentric transformations.

  12. Effects of asymmetrical stance and movement on body rotation in pushing.

    Science.gov (United States)

    Lee, Yun-Ju; Aruin, Alexander S

    2015-01-21

    Pushing objects in the presence of body asymmetries could increase the risk of back injury. Furthermore, when the object is heavy, it could exacerbate the effects induced by asymmetrical posture. We investigated how the use of asymmetrical posture and/or upper extremity movement affect vertical torque (Tz) and center of pressure (COP) displacement during pushing. Ten healthy volunteers were instructed to push objects of three different weights using two hands (symmetrical hand use) or one hand (asymmetrical hand use) while standing in symmetrical or asymmetrical foot-positions. The peak values of Tz and COP displacement in the medial-lateral direction (COPML) were analyzed. In cases of isolated asymmetry, changes in the Tz were mainly linked with effects of hand-use whereas effects of foot-position dominated changes in the COPML displacement. In cases of a combined asymmetry, the magnitudes of both Tz and COPML were additive when asymmetrical hand-use and foot-position induced the rotation of the lower and upper body in the same direction or subtractive when asymmetries resulted in the rotation of the body segments in the opposite directions. Moreover, larger Tz and COP displacements were seen when pushing the heavy weight. The results point out the importance of using Tz and COPML to describe the isolated or combined effects of asymmetrical upper extremity movement and asymmetrical posture on body rotation during pushing. Furthermore, it suggests that a proper combination of unilateral arm movement and foot placements could help to reduce body rotation even when pushing heavy objects. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Rotation-limited growth of three-dimensional body-centered-cubic crystals.

    Science.gov (United States)

    Tarp, Jens M; Mathiesen, Joachim

    2015-07-01

    According to classical grain growth laws, grain growth is driven by the minimization of surface energy and will continue until a single grain prevails. These laws do not take into account the lattice anisotropy and the details of the microscopic rearrangement of mass between grains. Here we consider coarsening of body-centered-cubic polycrystalline materials in three dimensions using the phase field crystal model. We observe, as a function of the quenching depth, a crossover between a state where grain rotation halts and the growth stagnates and a state where grains coarsen rapidly by coalescence through rotation and alignment of the lattices of neighboring grains. We show that the grain rotation per volume change of a grain follows a power law with an exponent of -1.25. The scaling exponent is consistent with theoretical considerations based on the conservation of dislocations.

  14. Tidal synchronization of an anelastic multi-layered body: Titan's synchronous rotation

    Science.gov (United States)

    Folonier, Hugo A.; Ferraz-Mello, Sylvio

    2017-12-01

    Tidal torque drives the rotational and orbital evolution of planet-satellite and star-exoplanet systems. This paper presents one analytical tidal theory for a viscoelastic multi-layered body with an arbitrary number of homogeneous layers. Starting with the static equilibrium figure, modified to include tide and differential rotation, and using the Newtonian creep approach, we find the dynamical equilibrium figure of the deformed body, which allows us to calculate the tidal potential and the forces acting on the tide generating body, as well as the rotation and orbital elements variations. In the particular case of the two-layer model, we study the tidal synchronization when the gravitational coupling and the friction in the interface between the layers is added. For high relaxation factors (low viscosity), the stationary solution of each layer is synchronous with the orbital mean motion ( n) when the orbit is circular, but the rotational frequencies increase if the orbital eccentricity increases. This behavior is characteristic in the classical Darwinian theories and in the homogeneous case of the creep tide theory. For low relaxation factors (high viscosity), as in planetary satellites, if friction remains low, each layer can be trapped in different spin-orbit resonances with frequencies n/2,n,3n/2,2n,\\ldots . When the friction increases, attractors with differential rotations are destroyed, surviving only commensurabilities in which core and shell have the same velocity of rotation. We apply the theory to Titan. The main results are: (i) the rotational constraint does not allow us to confirm or reject the existence of a subsurface ocean in Titan; and (ii) the crust-atmosphere exchange of angular momentum can be neglected. Using the rotation estimate based on Cassini's observation (Meriggiola et al. in Icarus 275:183-192, 2016), we limit the possible value of the shell relaxation factor, when a deep subsurface ocean is assumed, to γ _s≲ 10^{-9} s^{-1}, which

  15. Dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer

    International Nuclear Information System (INIS)

    Yang, Yun; Catalano, Suzanne; Kelsey, Chris R.; Yoo, David S.; Yin, Fang-Fang; Cai, Jing

    2014-01-01

    To quantitatively evaluate dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer. Overall, 11 lung SBRT patients (8 female and 3 male; mean age: 75.0 years) with medially located tumors were included. Treatment plans with simulated rotational offsets of 1°, 3°, and 5° in roll, yaw, and pitch were generated and compared with the original plans. Both clockwise and counterclockwise rotations were investigated. The following dosimetric metrics were quantitatively evaluated: planning target volume coverage (PTV V 100% ), max PTV dose (PTV D max ), percentage prescription dose to 0.35 cc of cord (cord D 0.35 cc ), percentage prescription dose to 0.35 cc and 5 cc of esophagus (esophagus D 0.35 cc and D 5 cc ), and volume of the lungs receiving at least 20 Gy (lung V 20 ). Statistical significance was tested using Wilcoxon signed rank test at the significance level of 0.05. Overall, small differences were found in all dosimetric matrices at all rotational offsets: 95.6% of differences were 100% , PTV D max , cord D 0.35 cc , esophagus D 0.35 cc , esophagus D 5 cc , and lung V 20 was − 8.36%, − 6.06%, 11.96%, 8.66%, 6.02%, and − 0.69%, respectively. No significant correlation was found between any dosimetric change and tumor-to-cord/esophagus distances (R 2 range: 0 to 0.44). Larger dosimetric changes and intersubject variations were observed at larger rotational offsets. Small dosimetric differences were found owing to rotational offsets up to 5° in lung SBRT for medially located tumors. Larger intersubject variations were observed at larger rotational offsets

  16. A rotating bluff-body disc for reduced variability in wind tunnel aerosol studies.

    Science.gov (United States)

    Koehler, Kirsten A; Anthony, T Renee; van Dyke, Michael; Volckens, John

    2011-01-01

    A rotating bluff-body disc (RBD) was developed to reduce spatiotemporal variability associated with sampling supermicron aerosol in low-velocity wind tunnels. The RBD is designed to rotate eight personal aerosol samplers around a circular path in a forward-facing plane aligned with the wind tunnel cross section. Rotation of the RBD allows each sampler to traverse an identical path about the wind tunnel cross section, which reduces the effects of spatial heterogeneity associated with dispersing supermicron aerosol in low-velocity wind tunnels. Samplers are positioned on the face of the RBD via sampling ports, which connect to an air manifold on the back of the disc. Flow through each sampler was controlled with a critical orifice or needle valve, allowing air to be drawn through the manifold with a single pump. A metal tube, attached to this manifold, serves as both the axis of rotation and the flow conduction path (between the samplers and the vacuum source). Validation of the RBD was performed with isokinetic samplers and 37-mm cassettes. For facing-the-wind tests, the rotation of the RBD significantly decreased intra-sampler variability when challenged with particle diameters from 1 to 100 μm. The RBD was then employed to determine the aspiration efficiency of Institute of Occupational Medicine (IOM) personal samplers under a facing-the-wind condition. Operation of IOM samplers on the RBD reduced the between-sampler variability for all particle sizes tested.

  17. Seasonal changes in total body water; body composition and water turnover in reindeer

    Directory of Open Access Journals (Sweden)

    Terje S. Larsen

    1985-05-01

    Full Text Available Total body water and water turnover were measured at different times throughout the year in 3 captive Norwegian reindeer, using a tritiated water dilution method (Holleman et al. 1982. Total body water (percent of body weight increased during late autumn and winter, from 59.1 ± 1.5 % in October to 72.5 ± 2.0 % in April. Using the equatation by Pace and Rathbun (1945 for predicting total body fat (% fat = 100 - % water/0.732, this increase in total body water indicates a concomitant reduction in body fat, from a maximum value of 18.9 ± 2.6 % (of body weight in October to a minimum of 0.9 ± 2.7 % in April. During summer, on the other hand, fat content increased at the expense of a reduced percentage of body water. Water turnover was low in winter (December - April, ranging between 30.8 ± 5.2and43.6 ± 13.5ml.d-'. kg-1, but increased nearly fourfold during summer (June-August with a maximum of 117.7 ± 5.9 ml.d-1. kg-1 in August. Positive correlations between water turnover and food intake and between water turnover and ambient temperature were found, the latter probably resulting from an incidental correlation between food intake and ambient temperature.Sesongmessige forandringer i totalt kroppsvann, kropps-sammensetning og vannomsetning hos reinsdyr.Abstract in Norwegian / Sammendrag: Totalt kroppsvann og vannomsetning av vann ble målt til forskjellige årstider i 3 norske reinsdyr ved hjelp av utvasking av tritiert vann (Holleman et al. 1982. Totalt kroppsvann (prosent av kroppsvekt økte utover høsten og vinteren, fra 59.1 ± 1.5 % i oktober til 72.5 ± 2.0 % i april. Ved hjelp av en ligning som er gitt av Pace og Rathbun (1945 for beregning av totalt kroppsfett (% fett = 100 - % vann/0.732, fant en at denne økningen i vanninnhold tilsvarte en samtidig reduksjon i fettinnhold, fra en maksimums-verdi på 18.9 ± 2.6 % av kroppsvekt i oktober til et minimum på 0.9 ± 2.7 % i april. Utover sommeren økte derimot innholdet av fett p

  18. Whole-body dose meters. Measurements of total activity

    International Nuclear Information System (INIS)

    Koeppe, P.; Klinikum Steglitz, Berlin

    1990-01-01

    By means of measurements using a whole-body dose meter, the course of the incorporation of radionuclides was established between April 1986 and May 1989 for unchanged conditions of alimentation, activity-conscious alimentation, and uniquely increased incorporation. Monitoring covered persons from the most different spheres of life. The incorporation is compared with the one resulting from nuclear weapons explosions in the atmosphere. (DG) [de

  19. Asymptotic structure of viscous incompressible flow around a rotating body, with nonvanishing flow field at infinity

    Czech Academy of Sciences Publication Activity Database

    Deuring, P.; Kračmar, S.; Nečasová, Šárka

    2017-01-01

    Roč. 68, č. 1 (2017), č. článku 16. ISSN 0044-2275 R&D Projects: GA ČR GA13-00522S Institutional support: RVO:67985840 Keywords : asymptotic profile * Pointwise decay * rotating body * stationary incompressible Navier–Stokes system Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 1.687, year: 2016 http://link.springer.com/article/10.1007%2Fs00033-016-0760-x

  20. Linearized stationary incompressible flow around rotating and translating bodies- Leray solution

    Czech Academy of Sciences Publication Activity Database

    Deuring, P.; Kračmar, S.; Nečasová, Šárka

    2014-01-01

    Roč. 7, č. 5 (2014), s. 967-979 ISSN 1937-1632 R&D Projects: GA ČR(CZ) GAP201/11/1304 Institutional support: RVO:67985840 Keywords : stationary Oseen problem * rotating body * Leray solution Subject RIV: BA - General Mathematics Impact factor: 0.567, year: 2014 http://www.aimsciences.org/journals/displayArticlesnew.jsp?paperID=9874

  1. Asymptotic structure of viscous incompressible flow around a rotating body, with nonvanishing flow field at infinity

    Czech Academy of Sciences Publication Activity Database

    Deuring, P.; Kračmar, S.; Nečasová, Šárka

    2017-01-01

    Roč. 68, č. 1 (2017), č. článku 16. ISSN 0044-2275 R&D Projects: GA ČR GA13-00522S Institutional support: RVO:67985840 Keywords : asymptotic profile * Pointwise decay * rotating body * stationary incompressible Navier–Stokes system Subject RIV: BA - General Math ematics OBOR OECD: Pure math ematics Impact factor: 1.687, year: 2016 http://link.springer.com/article/10.1007%2Fs00033-016-0760-x

  2. Quasi-stationary gravitational collapse of slowly rotating bodies in general relativity

    Energy Technology Data Exchange (ETDEWEB)

    Miller, J C [Oxford Univ. (UK). Dept. of Astrophysics

    1977-05-01

    This paper presents results of quasi-stationary collapse calculations for a class of slowly rotating non-homogeneous bodies in general relativity. The results are qualitatively similar to those obtained previously for homogeneous models indicating that the effects described for the homogeneous models are likely to have some relevance for the gravitational collapse of real stars towards the black hole state. There is also a discussion of some basic questions associated with such calculations.

  3. Motion of a Rigid Body Supported at One Point by a Rotating Arm

    Directory of Open Access Journals (Sweden)

    Jeffrey D. Stoen

    1993-01-01

    Full Text Available This article details a scheme for evaluating the stability of motions of a system consisting of a rigid body connected at one point to a rotating arm. The nonlinear equations of motion for the system are formulated, and a method for finding exact solutions representing motions that resemble a state of rest is presented. The equations are then linearized and roots of the eigensystem are classified and used to construct stability diagrams that facilitate the assessment of effects of varying the body's mass properties and system geometry, changing the position of the attachment joint, and adding energy dissipation in the joint.

  4. Increase of Total Body Water with Decrease of Body Mass while Running 100 km Nonstop--Formation of Edema?

    Science.gov (United States)

    Knechtle, Beat; Wirth, Andrea; Knechtle, Patrizia; Rosemann, Thomas

    2009-01-01

    We investigated whether ultraendurance runners in a 100-km run suffer a decrease of body mass and whether this loss consists of fat mass, skeletal muscle mass, or total body water. Male ultrarunners were measured pre- and postrace to determine body mass, fat mass, and skeletal muscle mass by using the anthropometric method. In addition,…

  5. In-vivo determination of total body water and lean body mass in subjects by deuterium dilution

    Energy Technology Data Exchange (ETDEWEB)

    Blagojevic, N; Allen, B J; Baur, L; Gaskin, K

    1988-12-01

    Total body water (TBW) estimation is one of a number of basic techniques required for the determination of body composition in normal and malnourished subjects. When combined with total body nitrogen (TBN) analysis by prompt gamma neutron activation, an accurate compartmental model of in vivo body composition can be formed, providing valuable nutritional and other data. This study examines the role of TBW on its own in evaluating lean body mass. Total body water was studied in six male and five female subjects using deuterium oxide and a Fourier transform infrared spectrometer. The lean body mass calculated from the results was compared with the lean body mass deduced from established total body nitrogen measurements. A four-compartment model was also used to calculate lean body mass. Excellent agreement was shown between lean body mass derived from TBW, the four-compartment model and TBN. Hence, TBW can provide a fast, cost-efficient method for evaluating normal subjects. However, for disease-induced malnutrition, or highly developed athletes, both TBN and TBW measurements are essential to establish an accurate picture of their body composition. TBW measurements alone can monitor the hydration state of patients and as such have a useful diagnostic value.

  6. In-vivo determination of total body water and lean body mass in subjects by deuterium dilution

    International Nuclear Information System (INIS)

    Blagojevic, N.; Allen, B.J.; Baur, L.; Gaskin, K.

    1988-01-01

    Total body water (TBW) estimation is one of a number of basic techniques required for the determination of body composition in normal and malnourished subjects. When combined with total body nitrogen (TBN) analysis by prompt gamma neutron activation, an accurate compartmental model of in vivo body composition can be formed, providing valuable nutritional and other data. This study examines the role of TBW on its own in evaluating lean body mass. Total body water was studied in six male and five female subjects using deuterium oxide and a Fourier transform infrared spectrometer. The lean body mass calculated from the results was compared with the lean body mass deduced from established total body nitrogen measurements. A four-compartment model was also used to calculate lean body mass. Excellent agreement was shown between lean body mass derived from TBW, the four-compartment model and TBN. Hence, TBW can provide a fast, cost-efficient method for evaluating normal subjects. However, for disease-induced malnutrition, or highly developed athletes, both TBN and TBW measurements are essential to establish an accurate picture of their body composition. TBW measurements alone can monitor the hydration state of patients and as such have a useful diagnostic value

  7. Gastrointestinal decontamination of dogs treated with total body irradiation and bone marrow transplantation

    NARCIS (Netherlands)

    Vriesendorp, H.M.; Heidt, P.J.; Zurcher, C.

    1981-01-01

    Procedures for total and selective gastrointestinal decontamination of dogs are described. The selective procedure removed only Gram negative aerobic bacteria, yeast and fungi. Dogs receiving total decontamination were less susceptible to the GI syndrome following total body irradiation (TBI) than

  8. A simple calibration of a whole-body counter for the measurement of total body potassium in humans

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; El-Fiki, S.A.; El-Enany, N.; Youssef, S.K.; Aly, A.M.; Abbas, M.T.

    1992-01-01

    A simple calibration procedure for the Inshas whole body counter for evaluating total body potassium has been adopted. More than 120 Egyptian employees in the Nuclear Research Center (N.R.C.) were studied for their total body potassium (TBK). The potassium values were found to have an average of 2.85±0.57 g K kg -1 body weight for males and 2.62±0.52 g K kg -1 for females, which are higher than the recommended value given for reference man by ICRP. The TBK varied directly with body build index and is slightly sex dependent (Author)

  9. Clinical aspects of accidents resulting in acute total body irradiation

    International Nuclear Information System (INIS)

    Cronkite, E.P.

    1988-01-01

    That the management of whole body radiation injury involves: (1) watchful waiting, (2) observation of the hematologic parameters, (3) use of antibiotics, platelet red cell and possibly granulocyte transfusions, (4) administration of hemopoietic molecular regulators of granulopoiesis, and (5) bone marrow transplantation as the last line of defense. The clinical indication for the preceding will not be discussed, since this will be a subject of later speakers in this conference. Certainly, if a radiation casualty is fortunate enough to have an identical twin, a marrow transplant may be lifesaving and certainly can do no harm to the patient, and there is little risk to the donor

  10. Radiographic analysis of partial or total vertebral body resection

    International Nuclear Information System (INIS)

    Whitten, C.G.; Hammer, G.H.; El-Khoury, G.Y.; Hugus, J.; Weinstein, J.N.

    1991-01-01

    Partial and total vertebrectomies are used in the treatment of primary and metastatic neoplasms of the spine. Serial radiographic studies are crucial in the follow-up of patients with vertebrectomies. This paper presents 33 cases and illustrates radiographic examples of both successful and complicated vertebrectomies, including radiographic signs of local tumor recurrence, loosening, migration or fracture of the hardware or methylmethacrylate, bone graft failure, and progressive spinal instability

  11. Custom rotating hinge total knee arthroplasty in patients with poliomyelitis affected limbs.

    Science.gov (United States)

    Rahman, Jeeshan; Hanna, Sammy A; Kayani, Babar; Miles, Jonathan; Pollock, Robin C; Skinner, John A; Briggs, Timothy W; Carrington, Richard W

    2015-05-01

    Total knee arthroplasty (TKA) in limbs affected by poliomyelitis is a technically challenging procedure. These patients often demonstrate acquired articular and metaphyseal angular deformities, bone loss, narrowness of the intramedullary canals, impaired quadriceps strength, flexion contractures and ligamentous laxity producing painful hyperextension. Thus, using condylar knee designs in these patients will likely result in early failure because of instability and abnormal load distribution. The aim of this study was to assess the outcomes associated with use of the customised (SMILES) rotating-hinge knee system at our institution for TKA in poliomyelitis-affected limbs. We retrospectively reviewed the outcome of 14 TKAs using the (SMILES) prosthesis in 13 patients with limbs affected by poliomyelitis. All patients had painful unstable knees with hyperextension. There were ten females and three males with a mean age of 66 years (range 51-84) at time of surgery. Patients were followed up clinically, radiologically and functionally with the Oxford knee score (OKS). Mean follow-up was 72 months (16-156). There were no immediate or early complications. One patient fell and sustained a peri-prosthetic fracture at seven months requiring revision to a longer stem. Radiological evaluation showed satisfactory alignment with no signs of loosening in all cases. Mean OKS improved from 11.6 (4-18) to 31.5 (18-40) postoperatively (p poliomyelitis. The device compensates well for ligamentous insufficiency as well as for any associated bony deformity.

  12. Normal levels of total body sodium and chlorine by neutron activation analysis

    International Nuclear Information System (INIS)

    Kennedy, N.S.J.; Eastell, R.; Smith, M.A.; Tothill, P.

    1983-01-01

    In vivo neutron activation analysis was used to measure total body sodium and chlorine in 18 male and 18 female normal adults. Corrections for body size were developed. Normalisation factors were derived which enable the prediction of the normal levels of sodium and chlorine in a subject. The coefficient of variation of normalised sodium was 5.9% in men and 6.9% in women, and of normalised chlorine 9.3% in men and 5.5% in women. In the range examined (40-70 years) no significant age dependence was observed for either element. Total body sodium was correlated with total body chlorine and total body calcium. Sodium excess, defined as the amount of body sodium in excess of that associated with chlorine, also correlated well with total body calcium. In females there was a mean annual loss of sodium excess of 1.2% after the menopause, similar to the loss of calcium. (author)

  13. Dose compensation of the total body irradiation therapy

    International Nuclear Information System (INIS)

    Lin, J.-P.; Chu, T.-C.; Liu, M.-T.

    2001-01-01

    The aim of the study is to improve dose uniformity in the body by the compensator-rice and to decrease the dose to the lung by the partial lung block. Rando phantom supine was set up to treat bilateral fields with a 15 MV linear accelerator at 415 cm treatment distance. The experimental procedure included three parts. The first part was the bilateral irradiation without rice compensator, and the second part was with rice compensator. In the third part, rice compensator and partial lung block were both used. The results of thermoluminescent dosimeters measurements indicated that without rice compensator the dose was non-uniform. Contrarily, the average dose homogeneity with rice compensator was measured within ±5%, except for the thorax region. Partial lung block can reduce the dose which the lung received. This is a simple method to improve the dose homogeneity and to reduce the lung dose received. The compensator-rice is cheap, and acrylic boxes are easy to obtain. Therefore, this technique is suitable for more studies

  14. SU-E-J-165: Dosimetric Impact of Liver Rotations in Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pinnaduwage, D; Paulsson, A; Sudhyadhom, A; Chen, J; Chang, A; Anwar, M; Gottschalk, A; Yom, S S.; Descovich, M [University of California San Francisco, San Francisco, CA (United States)

    2015-06-15

    Purpose: Often in liver stereotactic body radiotherapy a single fiducial is implanted near the tumor for image-guided treatment delivery. In such cases, rotational corrections are calculated based on the spine. This study quantifies rotational differences between the spine and liver, and investigates the corresponding dosimetric impact. Methods: Seven patients with 3 intrahepatic fiducials and 4DCT scans were identified. The planning CT was separately co-registered with 4 phases of the 4DCT (0%, 50%, 100% inhale and 50% exhale) by 1) rigid registration of the spine, and 2) point-based registration of the 3 fiducials. Rotation vectors were calculated for each registration. Translational differences in fiducial positions between the 2 registrations methods were investigated. Dosimetric impact due to liver rotations and deformations was assessed using critical structures delineated on the 4DCT phases. For dose comparisons, a single fiducial was translationally aligned following spine alignment to represent what is typically done in the clinic. Results: On average, differences between spine and liver rotations during the 0%, 50%, 100% inhale, and 50% exhale phases were 3.23°, 3.27°, 2.26° and 3.11° (pitch), 3.00°, 2.24°, 3.12° and 1.73° (roll), and 1.57°, 1.98°, 2.09° and 1.36° (yaw), respectively. The maximum difference in rotations was 12°, with differences of >3° seen in 14/28 (pitch), 10/28 (roll), and 6/28 (yaw) cases. Average fiducial displacements of 2.73 (craniocaudal), 1.04 (lateral) and 1.82 mm (vertical) were seen. Evaluating percent dose differences for 5 patients at the peaks of the respiratory cycle, the maximum dose to the duodenum, stomach, bowel and esophagus differed on average by 11.4%, 5.3%, 11.2% and 49.1% between the 2 registration methods. Conclusion: Lack of accounting for liver rotation during treatment might Result in clinically significant dose differences to critical structures. Both rotational and translational deviations

  15. Dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yun; Catalano, Suzanne; Kelsey, Chris R.; Yoo, David S.; Yin, Fang-Fang; Cai, Jing, E-mail: jing.cai@duke.edu

    2014-04-01

    To quantitatively evaluate dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer. Overall, 11 lung SBRT patients (8 female and 3 male; mean age: 75.0 years) with medially located tumors were included. Treatment plans with simulated rotational offsets of 1°, 3°, and 5° in roll, yaw, and pitch were generated and compared with the original plans. Both clockwise and counterclockwise rotations were investigated. The following dosimetric metrics were quantitatively evaluated: planning target volume coverage (PTV V{sub 100%}), max PTV dose (PTV D{sub max}), percentage prescription dose to 0.35 cc of cord (cord D{sub 0.35} {sub cc}), percentage prescription dose to 0.35 cc and 5 cc of esophagus (esophagus D{sub 0.35} {sub cc} and D{sub 5} {sub cc}), and volume of the lungs receiving at least 20 Gy (lung V{sub 20}). Statistical significance was tested using Wilcoxon signed rank test at the significance level of 0.05. Overall, small differences were found in all dosimetric matrices at all rotational offsets: 95.6% of differences were < 1% or < 1 Gy. Of all rotational offsets, largest change in PTV V{sub 100%}, PTV D{sub max}, cord D{sub 0.35} {sub cc}, esophagus D{sub 0.35} {sub cc}, esophagus D{sub 5} {sub cc}, and lung V{sub 20} was − 8.36%, − 6.06%, 11.96%, 8.66%, 6.02%, and − 0.69%, respectively. No significant correlation was found between any dosimetric change and tumor-to-cord/esophagus distances (R{sup 2} range: 0 to 0.44). Larger dosimetric changes and intersubject variations were observed at larger rotational offsets. Small dosimetric differences were found owing to rotational offsets up to 5° in lung SBRT for medially located tumors. Larger intersubject variations were observed at larger rotational offsets.

  16. Osteochondroma after total body irradiation in bone marrow transplant recipients. Report of two cases

    International Nuclear Information System (INIS)

    Maeda, Go; Yokoyama, Ryohei; Ohtomo, Katsuyuki; Takayama, Jun; Beppu, Yasuo; Fukuma, Hisatoshi; Ohira, Mutsuro

    1996-01-01

    We present two cases of osteochondroma after total body irradiation in bone marrow recipients, the first in a 6-year-old boy with juvenile chronic myelogenous leukemia and the second in a 13-year-old boy with acute myelogenous leukemia. The patients developed multiple osteochondromas three years and seven years, respectively, after 12 Gy of total body irradiation. Neither had a family history of hereditary multiple osteochondromatosis. A review of the English literature revealed only one report describing five cases of osteochondroma after 12 Gy of total body irradiation in bone marrow transplant recipients. Osteochondroma should be considered as an additional adverse effect of total body irradiation. (author)

  17. Myeloproliferative disorders in patients with rheumatoid arthritis treated with total body irradiation

    International Nuclear Information System (INIS)

    Urowitz, M.B.; Rider, W.D.

    1985-01-01

    Four patients with refractory rheumatoid arthritis were treated with total body irradiation administered in two sittings, 300 to 400 rads to each half of the body. All four patients had taken antimetabolites prior to receiving total body irradiation, and two continued to use them after total body irradiation. Two patients had taken alkylating agents before, and one had used them after total body irradiation. All patients showed clinical improvement. However, in two patients myeloproliferative disorders developed: a myelodysplastic preleukemia at 40 months after total body irradiation in one and acute myelogenous leukemia at 25 months in the other. Total body irradiation differs from total nodal irradiation in the total dose of irradiation (300 to 400 rads versus 2,000 to 3,000), and in the duration of the therapy (two sittings versus treatment over several weeks to months). Furthermore, the patients in the total body irradiation study frequently used cytotoxic drugs before and/or after irradiation, whereas in one total nodal irradiation study, azathioprine (2 mg/kg per day or less) was permitted, but no other cytotoxic agents were allowed. Rheumatologists may therefore face a binding decision when deciding to treat a patient with rheumatoid arthritis with either a cytotoxic drug or irradiation

  18. Rotational Failure of Rubble-pile Bodies: Influences of Shear and Cohesive Strengths

    Science.gov (United States)

    Zhang, Yun; Richardson, Derek C.; Barnouin, Olivier S.; Michel, Patrick; Schwartz, Stephen R.; Ballouz, Ronald-Louis

    2018-04-01

    The shear and cohesive strengths of a rubble-pile asteroid could influence the critical spin at which the body fails and its subsequent evolution. We present results using a soft-sphere discrete element method to explore the mechanical properties and dynamical behaviors of self-gravitating rubble piles experiencing increasing rotational centrifugal forces. A comprehensive contact model incorporating translational and rotational friction and van der Waals cohesive interactions is developed to simulate rubble-pile asteroids. It is observed that the critical spin depends strongly on both the frictional and cohesive forces between particles in contact; however, the failure behaviors only show dependence on the cohesive force. As cohesion increases, the deformation of the simulated body prior to disruption is diminished, the disruption process is more abrupt, and the component size of the fissioned material is increased. When the cohesive strength is high enough, the body can disaggregate into similar-size fragments, which could be a plausible mechanism to form asteroid pairs or active asteroids. The size distribution and velocity dispersion of the fragments in high-cohesion simulations show similarities to the disintegrating asteroid P/2013 R3, indicating that this asteroid may possess comparable cohesion in its structure and experience rotational fission in a similar manner. Additionally, we propose a method for estimating a rubble pile’s friction angle and bulk cohesion from spin-up numerical experiments, which provides the opportunity for making quantitative comparisons with continuum theory. The results show that the present technique has great potential for predicting the behaviors and estimating the material strengths of cohesive rubble-pile asteroids.

  19. Serum protein concentration in low-dose total body irradiation of normal and malnourished rats

    International Nuclear Information System (INIS)

    Viana, W.C.M.; Lambertz, D.; Borges, E.S.; Neto, A.M.O.; Lambertz, K.M.F.T.; Amaral, A.

    2016-01-01

    Among the radiotherapeutics' modalities, total body irradiation (TBI) is used as treatment for certain hematological, oncological and immunological diseases. The aim of this study was to evaluate the long-term effects of low-dose TBI on plasma concentration of total protein and albumin using prematurely and undernourished rats as animal model. For this, four groups with 9 animals each were formed: Normal nourished (N); Malnourished (M); Irradiated Normal nourished (IN); Irradiated Malnourished (IM). At the age of 28 days, rats of the IN and IM groups underwent total body gamma irradiation with a source of cobalt-60. Total protein and Albumin in the blood serum was quantified by colorimetry. This research indicates that procedures involving low-dose total body irradiation in children have repercussions in the reduction in body-mass as well as in the plasma levels of total protein and albumin. Our findings reinforce the periodic monitoring of total serum protein and albumin levels as an important tool in long-term follow-up of pediatric patients in treatments associated to total body irradiation. - Highlights: • Low-dose total body irradiation (TBI) in children have repercussions in their body-mass. • Long-term total protein and albumin levels are affected by TBI. • The monitoring of total protein and albumin levels are useful in the follow-up of TBI pediatric patients.

  20. Total and cause-specific mortality of U.S. nurses working rotating night shifts.

    Science.gov (United States)

    Gu, Fangyi; Han, Jiali; Laden, Francine; Pan, An; Caporaso, Neil E; Stampfer, Meir J; Kawachi, Ichiro; Rexrode, Kathryn M; Willett, Walter C; Hankinson, Susan E; Speizer, Frank E; Schernhammer, Eva S

    2015-03-01

    Rotating night shift work imposes circadian strain and is linked to the risk of several chronic diseases. To examine associations between rotating night shift work and all-cause; cardiovascular disease (CVD); and cancer mortality in a prospective cohort study of 74,862 registered U.S. nurses from the Nurses' Health Study. Lifetime rotating night shift work (defined as ≥3 nights/month) information was collected in 1988. During 22 years (1988-2010) of follow-up, 14,181 deaths were documented, including 3,062 CVD and 5,413 cancer deaths. Cox proportional hazards models estimated multivariable-adjusted hazard ratios (HRs) and 95% CIs. All-cause and CVD mortality were significantly increased among women with ≥5 years of rotating night shift work, compared to women who never worked night shifts. Specifically, for women with 6-14 and ≥15 years of rotating night shift work, the HRs were 1.11 (95% CI=1.06, 1.17) and 1.11 (95% CI=1.05, 1.18) for all-cause mortality and 1.19 (95% CI=1.07, 1.33) and 1.23 (95% CI=1.09, 1.38) for CVD mortality. There was no significant association between rotating night shift work and all-cancer mortality (HR≥15years=1.08, 95% CI=0.98, 1.19) or mortality of any individual cancer, with the exception of lung cancer (HR≥15years=1.25, 95% CI=1.04, 1.51). Women working rotating night shifts for ≥5 years have a modest increase in all-cause and CVD mortality; those working ≥15 years of rotating night shift work have a modest increase in lung cancer mortality. These results add to prior evidence of a potentially detrimental effect of rotating night shift work on health and longevity. Copyright © 2015 American Journal of Preventive Medicine. All rights reserved.

  1. A Triple Iron Triathlon Leads to a Decrease in Total Body Mass but Not to Dehydration

    Science.gov (United States)

    Knechtle, Beat; Knechtle, Patrizia; Rosemann, Thomas; Oliver, Senn

    2010-01-01

    A loss in total body mass during an ultraendurance performance is usually attributed to dehydration. We identified the changes in total body mass, fat mass, skeletal muscle mass, and selected markers of hydration status in 31 male nonprofessional ultratriathletes participating in a Triple Iron triathlon involving 11.4 km swimming, 540 km cycling…

  2. INTEGRATION OF THE ROTATION OF AN EARTH-LIKE BODY AS A PERTURBED SPHERICAL ROTOR

    International Nuclear Information System (INIS)

    Ferrer, Sebastian; Lara, Martin

    2010-01-01

    For rigid bodies close to a sphere, we propose an analytical solution that is free from elliptic integrals and functions, and can be fundamental for application to perturbed problems. After reordering the Hamiltonian as a perturbed spherical rotor, the Lie-series solution is generated up to an arbitrary order. Using the inertia parameters of different solar system bodies, the comparison of the approximate series solution with the exact analytical one shows that the precision reached with relatively low orders is at the same level of the observational accuracy for the Earth and Mars. Thus, for instance, the periodic errors of the mathematical solution are confined to the microarcsecond level with a simple second-order truncation for the Earth. On the contrary, higher orders are required for the mathematical solution to reach a precision at the expected level of accuracy of proposed new theories for the rotational dynamics of the Moon.

  3. Body fixed frame, rigid gauge rotations and large N random fields in QCD

    International Nuclear Information System (INIS)

    Levit, S.

    1995-01-01

    The ''body fixed frame'' with respect to local gauge transformations is introduced. Rigid gauge ''rotations'' in QCD and their Schroedinger equation are studied for static and dynamic quarks. Possible choices of the rigid gauge field configuration corresponding to a non-vanishing static colormagnetic field in the ''body fixed'' frame are discussed. A gauge invariant variational equation is derived in this frame. For large number N of colors the rigid gauge field configuration is regarded as random with maximally random probability distribution under constraints on macroscopic-like quantities. For the uniform magnetic field the joint probability distribution of the field components is determined by maximizing the appropriate entropy under the area law constraint for the Wilson loop. In the quark sector the gauge invariance requires the rigid gauge field configuration to appear not only as a background but also as inducing an instantaneous quark-quark interaction. Both are random in the large N limit. (orig.)

  4. Galectin-3 levels relate in children to total body fat, abdominal fat, body fat distribution, and cardiac size.

    Science.gov (United States)

    Dencker, Magnus; Arvidsson, Daniel; Karlsson, Magnus K; Wollmer, Per; Andersen, Lars B; Thorsson, Ola

    2018-03-01

    Galectin-3 has recently been proposed as a novel biomarker for cardiovascular disease in adults. The purpose of this investigation was to assess relationships between galectin-3 levels and total body fat, abdominal fat, body fat distribution, aerobic fitness, blood pressure, left ventricular mass, left atrial size, and increase in body fat over a 2-year period in a population-based sample of children. Our study included 170 children aged 8-11 years. Total fat mass and abdominal fat were measured by dual-energy x-ray absorptiometry (DXA). Body fat distribution was expressed as abdominal fat/total fat mass. Maximal oxygen uptake was assessed by indirect calorimetry during a maximal exercise test and scaled to body mass. Systolic and diastolic blood pressure and pulse pressure were measured. Left atrial size, left ventricular mass, and relative wall thickness were measured by echocardiography. Frozen serum samples were analyzed for galectin-3 by the Proximity Extension Assay technique. A follow-up DXA scan was performed in 152 children 2 years after the baseline exam. Partial correlations, with adjustment for sex and age, between galectin-3 versus body fat measurements indicated weak to moderate relationships. Moreover, left atrial size, left ventricular mass, and relative wall thickness and pulse pressure were also correlated with galectin-3. Neither systolic blood pressure nor maximal oxygen uptake was correlated with galectin-3. There was also a correlation between galectin-3 and increase in total body fat over 2 years, while no such correlations were found for the other fat measurements. More body fat and abdominal fat, more abdominal body fat distribution, more left ventricular mass, and increased left atrial size were all associated with higher levels of galectin-3. Increase in total body fat over 2 years was also associated with higher levels of galectin-3. What is Known: • Galectin-3 has been linked to obesity and been proposed to be a novel biomarker

  5. Magnetic fields produced by rotating symmetrical bodies with homogeneous surface charge density

    International Nuclear Information System (INIS)

    Espejel-Morales, R; Murguía-Romero, G; Calles, A; Cabrera-Bravo, E; Morán-López, J L

    2016-01-01

    We present a numerical calculation for the stationary magnetic field produced by different rotating bodies with homogeneous and constant surface charge density. The calculation is done by superposing the magnetic field produced by a set of loops of current which mimic the magnetic field produced by belts of current defined by slices of fixed width. We consider the cases of a sphere, ellipsoids, open and closed cylinders and a combination of these in a dumbbell -like shell. We also plot their magnetic field lines using a technique that make use of the Runge–Kutta fourth-order method. Up to our knowledge, the case of closed cylinders was not calculated before. In contrast to previous results, we find that the magnetic field inside finite hollow bodies is homogeneous only in the case of a sphere. This is consequence of the fact that, for the sphere, the surface of any slice taken perpendicularly to the rotation axis, depends only on its thickness, like in the case of an infinite cylinder. (paper)

  6. Ten Year Follow-Up of Gap Balanced, Rotating Platform Total Knee Arthroplasty in Patients Under 60 Years of Age.

    Science.gov (United States)

    Lee, Jason H; Barnett, Steven L; Patel, Jay J; Nassif, Nader A; Cummings, Dennis J; Gorab, Robert S

    2016-01-01

    68 patients (91 primary total knee arthroplasties) were evaluated at a mean 10-year, minimum 5 year follow up in patients younger than sixty years of age utilizing the gap balanced, rotating platform design. Follow up assessment included implant survivorship, adverse events, x-rays, Knee Society rating system and clinical evaluation. Three revisions were performed with only one for aseptic loosening at 45 months. Two manipulations were performed in the early postoperative period. Survivorship of the rotating platform, gap balanced knee was 96.7% using surgical revision for any reason and 98.9% using aseptic loosening as endpoints. The rotating platform design using the gap balancing technique in young patients had excellent survivorship at 10-year mean follow up. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. An additional reference axis improves femoral rotation alignment in image-free computer navigation assisted total knee arthroplasty.

    Science.gov (United States)

    Inui, Hiroshi; Taketomi, Shuji; Nakamura, Kensuke; Sanada, Takaki; Tanaka, Sakae; Nakagawa, Takumi

    2013-05-01

    Few studies have demonstrated improvement in accuracy of rotational alignment using image-free navigation systems mainly due to the inconsistent registration of anatomical landmarks. We have used an image-free navigation for total knee arthroplasty, which adopts the average algorithm between two reference axes (transepicondylar axis and axis perpendicular to the Whiteside axis) for femoral component rotation control. We hypothesized that addition of another axis (condylar twisting axis measured on a preoperative radiograph) would improve the accuracy. One group using the average algorithm (double-axis group) was compared with the other group using another axis to confirm the accuracy of the average algorithm (triple-axis group). Femoral components were more accurately implanted for rotational alignment in the triple-axis group (ideal: triple-axis group 100%, double-axis group 82%, P<0.05). Copyright © 2013 Elsevier Inc. All rights reserved.

  8. In vivo measurement of total body carbon using 238Pu/Be neutron sources

    International Nuclear Information System (INIS)

    Sutcliffe, J.F.; Mitra, S.; Hill, G.L.

    1990-01-01

    Total body carbon has been measured by in vivo neutron activation analysis (IVNAA) in 278 surgical gastroenterological patients and 29 normal volunteers. This is based on the inelastic scattering reaction { 12 C(n,n') 12 C*} for neutrons with energy above 4.8MeV, producing 4.43 MeV gamma rays. Since only part of the body is scanned, total body carbon is estimated as the ratio of the gamma ray emission from carbon to the emission from hydrogen, using hydrogen as the internal standard. The precision of the estimate is ±1.6kg for a whole body dose of 0.3mSv. There is a significant difference between the estimates of total body water from IVNAA measurements of carbon and nitrogen and measurements of body water in these subjects by tritium dilution (t=3.1, p < 0.005). (author)

  9. Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population

    Directory of Open Access Journals (Sweden)

    Mahmoud Jabalameli

    2016-04-01

    Full Text Available Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational alignment in preoperative CT scans of Iranian patients who were candidates for total knee arthroplasty and the effects of age, gender, and knee alignment on these relationships. Methods: One hundred and eight cases who were admitted to two university hospitals for total knee arthroplasty were included in this study. The rotation of the distal femur was evaluated using single axial CT images through the femoral epicondyle. Four lines were drawn digitally in this view: anatomical and surgical transepicondylar axes, posterior condylar axis and the Whiteside anteroposterior line. The alignment of the extremity was evaluated in the standing alignment view. Then the angles were measured along these lines and their relationship was evaluated. Results: The mean angle between the anatomical transepicondylar axis and posterior condylar axis and between the surgical transepicondylar axis and posterior condylar axis were 5.9 ± 1.6 degrees and 1.6±1.7 degrees respectively. The mean angle between the Whiteside’s anteroposterior line and the line perpendicular to the posterior condylar axis was 3.7±2.1 degrees. Significant differences existed between the two genders in these relationships. No significant correlation between the age of patients and angles of the distal femur was detected. The anatomical surgical transepicondylar axis was in 4.3 degrees external rotation in relation to the surgical transepicondylar axis. Conclusion: Preoperative CT scanning can help accurately determine rotational landmarks of the distal femur. If one of the reference axes cannot be

  10. One-dimensional analysis of plane and radial thin film flows including solid-body rotation

    Science.gov (United States)

    Thomas, S.; Hankey, W.; Faghri, A.; Swanson, T.

    1989-01-01

    The flow of a thin liquid film with a free surface along a horizontal plate which emanates from a pressurized vessel is examined by integrating the equations of motion across the thin liquid layer and discretizing the integrated equations using finite difference techniques. The effects of 0-g and solid-body rotation will be discussed. The two cases of interest are plane flow and radial flow. In plane flow, the liquid is considered to be flowing along a channel with no change in the width of the channel, whereas in radial flow the liquid spreads out radially over a disk, so that the area changes along the radius. It is desired to determine the height of the liquid film at any location along the plate of disk, so that the heat transfer from the plate or disk can be found. The possibility that the flow could encounter a hydraulic jump is accounted for.

  11. Uniqueness of exterior axisymmetric solution for a rotating charged body in the relativistic theory of gravitation

    International Nuclear Information System (INIS)

    Karabut, P.V.; Chugreev, Yu.V.

    1989-01-01

    The relativistic theory of gravitation (RTG), which is constructed on the basis of Minkowski spacetime, the geometrization principle, and the notion of the gravitational field var-phi mn as a physical field in the spirit of Faraday and Maxwell, explains all known gravitational experiments and gives a new prediction for the evolution of the universe, collapse, etc. The RTG determines the structure of the gravitational field as a field possessing spins 2 and 0 and all conservation laws for energy, momentum, and angular momentum. An exact solution of the complete simultaneous system of equations of the relativistic theory of gravitation and Maxwell's equations is found in the axisymmetric case for an electrically charged rotating body. The uniqueness of this solution is proved

  12. Instability modes on a solid-body-rotation flow in a finite-length pipe

    Science.gov (United States)

    Feng, Chunjuan; Liu, Feng; Rusak, Zvi; Wang, Shixiao

    2017-09-01

    Numerical solutions of the incompressible Navier-Stokes equations are obtained to study the time evolution of both axisymmetric and three-dimensional perturbations to a base solid-body-rotation flow in a finite-length pipe with non-periodic boundary conditions imposed at the pipe inlet and outlet. It is found that for a given Reynolds number there exists a critical swirl number beyond which the initial perturbations grow, in contrast to the solid-body rotation flow in an infinitely-long pipe or a finite-length pipe with periodic inlet and exit boundary conditions for which the classical Kelvin analysis and Rayleigh stability criterion affirm neutrally stable for all levels of swirl. This paper uncovers for the first time the detailed evolution of the perturbations in both the axisymmetric and three-dimensional situations. The computations reveal a linear growth stage of the perturbations with a constant growth rate after a brief initial period of decay of the imposed initial perturbations. The fastest growing axisymmetric and three-dimensional instability modes and the associated growth rates are identified numerically for the first time. The computations show that the critical swirl number increases and the growth rate of instability decreases at the same swirl number with decreasing Reynolds number. The growth rate of the axisymmetric mode at high Reynolds number agrees well with previous stability theory for inviscid flow. More importantly, three-dimensional simulations uncover that the most unstable mode is the spiral type m = 1 mode, which appears at a lower critical swirl number than that for the onset of the axisymmetric mode. This spiral mode grows faster than the unstable axisymmetric mode at the same swirl. Moreover, the computations reveal that after the linear growing stage of the perturbation the flow continues to evolve nonlinearly to a saturated axisymmetric vortex breakdown state.

  13. Instability modes on a solid-body-rotation flow in a finite-length pipe

    Directory of Open Access Journals (Sweden)

    Chunjuan Feng

    2017-09-01

    Full Text Available Numerical solutions of the incompressible Navier-Stokes equations are obtained to study the time evolution of both axisymmetric and three-dimensional perturbations to a base solid-body-rotation flow in a finite-length pipe with non-periodic boundary conditions imposed at the pipe inlet and outlet. It is found that for a given Reynolds number there exists a critical swirl number beyond which the initial perturbations grow, in contrast to the solid-body rotation flow in an infinitely-long pipe or a finite-length pipe with periodic inlet and exit boundary conditions for which the classical Kelvin analysis and Rayleigh stability criterion affirm neutrally stable for all levels of swirl. This paper uncovers for the first time the detailed evolution of the perturbations in both the axisymmetric and three-dimensional situations. The computations reveal a linear growth stage of the perturbations with a constant growth rate after a brief initial period of decay of the imposed initial perturbations. The fastest growing axisymmetric and three-dimensional instability modes and the associated growth rates are identified numerically for the first time. The computations show that the critical swirl number increases and the growth rate of instability decreases at the same swirl number with decreasing Reynolds number. The growth rate of the axisymmetric mode at high Reynolds number agrees well with previous stability theory for inviscid flow. More importantly, three-dimensional simulations uncover that the most unstable mode is the spiral type m = 1 mode, which appears at a lower critical swirl number than that for the onset of the axisymmetric mode. This spiral mode grows faster than the unstable axisymmetric mode at the same swirl. Moreover, the computations reveal that after the linear growing stage of the perturbation the flow continues to evolve nonlinearly to a saturated axisymmetric vortex breakdown state.

  14. Gigapixel photography for skin cancer surveillance: a novel alternative to total-body photography.

    Science.gov (United States)

    Mikailov, Anar; Blechman, Adam

    2013-11-01

    There is substantial evidence supporting the use of cutaneous imaging in combination with standard total-body skin examinations for early detection and treatment of melanoma. In the last 2 decades, total-body photography (TBP) has been widely used in combination with standard total-body skin examinations for active skin cancer surveillance with proven clinical utility; however, the groundbreaking image detail provided by gigapixel photography (GP) could improve dermatologists' ability to monitor suspicious lesions and therefore could serve a critical role in supplementing traditional total-body skin examinations for skin cancer surveillance. Although it has been successfully implemented in other fields, future studies are required to determine the effectiveness of GP in dermatology.

  15. Total body irradiation as a form of preparation for bone marrow transplantation

    International Nuclear Information System (INIS)

    Inoue, Toshihiko

    1987-01-01

    The history of total body irradiation and bone marrow transplantation is surprisingly old. Following the success of Thomas et al. in the 1970s, bone marrow transplantation appeared to be the sole curative treatment modality for high-risk leukemia. A supralethal dose of total body irradiation was widely accepted as a form of preparation for bone marrow transplantation. In this paper, I described the present status of bone marrow transplantation for leukemia patients in Japan based on the IVth national survey. Since interstitial pneumonitis was one of the most life threatening complications after bone marrow transplantation, I mentioned the dose, dose-rate and fraction of total body irradiation in more detail. In addition, I dealt with some problems of the total body irradiation, such as dose prescription, compensating contour as well as inhomogeneity, and shielding for the highrisk organs. (author) 82 refs

  16. Total and regional body-composition changes in early postmenopausal women

    DEFF Research Database (Denmark)

    Wang, Q; Hassager, C; Ravn, Pernille

    1994-01-01

    Total and regional body composition were measured in 373 early postmenopausal women aged 49-60 y by dual-energy x-ray absorptiometry to evaluate whether the changes in body composition in the early postmenopausal years are related to menopause itself or merely to age. Both fat mass and fat...

  17. Correlation of total body potassium and leukemic cell mass in patients with chronic lymphocytic leukemia

    International Nuclear Information System (INIS)

    Chandra, P.; Sawitsky, A.; Chanana, A.D.; Chikkappa, G.; Cohn, S.H.; Rai, K.R.; Cronkity, E.P.

    1979-01-01

    Total body leukemic mass in patients with chronic lymphocytic leukemia (CLL) was measured by quantitation of total body potassium (TBK) with a whole-body counter. In addition, the predicted normal total body potassium (Kp) for each patient was calculated from an empirically derived relationship involving height, weight age, and sex. Both the absolute TBK and the relative excess of total body potassium (TBK/Kp) were related to the stage of disease. Patients in the early stages of CLL were found to have lower TBK and TBK/Kp than patients in the late stages of disease. Both of these parameters increased with the successively advanced stages of the disease. The clinically monitored reduction of leukemic cell mass following therapy was accompanied by reductions in TBK and TBK/Kp. Data presented support the notion that TBK/Kp is a useful indicator of the total body leukemic mass. Futhermore, the results of these studies quantitatively validate the proposed clinical staging system for CLL. Quantitation of TBK by a whole-body counter is an accurate and noninvasive procedure and does not require administration of isotopes

  18. Total body fat as a possible indicator of metabolic syndrome in adults

    Directory of Open Access Journals (Sweden)

    Edgar Navarro Lechuga

    2016-09-01

    Full Text Available Introduction: The metabolic syndrome is a set of factors related to insulin resistance, which increases the likelihood of coronary events. It is important timely onset identifying to reduce its prevalence. Objective: To explore the percentage of total body fat as indicator of metabolic syndrome in adults from Soledad, Colombia. Material and Methods: Cross-sectional study. n=99 adults (non-pregnant, nor subjects with psychomotor disturbances. Blood samples were taken: total cholesterol, HDL; triglycerides and glucose. Waist circumference, Body Mass Index and body fat by bioimpedance and skinfold thickness were measured. Diagnosis of metabolic syndrome was made according to NHLBI/AHA, ATP III and IDF criteria. Subjects with and without metabolic syndrome according to total body fat averages were compared. Results: The average percentage of body fat was higher (p0.05 in the classification according to ATP III in women, where the average fat percentage was 39.31 % in those with metabolic syndrome and 37.7% in those not suffering. Conclusions: Subjects with metabolic syndrome have higher mean total body fat, significantly, compared with those who did not, so it could be considered the values of total body fat obtained by bioimpedance as future indicators of metabolic syndrome, both as screening and control.

  19. Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient Care.

    Science.gov (United States)

    Cherry, Simon R; Jones, Terry; Karp, Joel S; Qi, Jinyi; Moses, William W; Badawi, Ramsey D

    2018-01-01

    PET is widely considered the most sensitive technique available for noninvasively studying physiology, metabolism, and molecular pathways in the living human being. However, the utility of PET, being a photon-deficient modality, remains constrained by factors including low signal-to-noise ratio, long imaging times, and concerns about radiation dose. Two developments offer the potential to dramatically increase the effective sensitivity of PET. First by increasing the geometric coverage to encompass the entire body, sensitivity can be increased by a factor of about 40 for total-body imaging or a factor of about 4-5 for imaging a single organ such as the brain or heart. The world's first total-body PET/CT scanner is currently under construction to demonstrate how this step change in sensitivity affects the way PET is used both in clinical research and in patient care. Second, there is the future prospect of significant improvements in timing resolution that could lead to further effective sensitivity gains. When combined with total-body PET, this could produce overall sensitivity gains of more than 2 orders of magnitude compared with existing state-of-the-art systems. In this article, we discuss the benefits of increasing body coverage, describe our efforts to develop a first-generation total-body PET/CT scanner, discuss selected application areas for total-body PET, and project the impact of further improvements in time-of-flight PET. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  20. Phase-II trial of fractionated total body radiation in bone marrow transplantation for acute leukemia

    International Nuclear Information System (INIS)

    Gale, R.P.; Opelz, G.; Feig, S.

    1979-01-01

    The addition of low doses of fractionated total body irradiation and a radiosensitizing agent to more conventional doses of total body irradiation was well tolerated but did not improve the antileukemic effect. The DAFT regimen was not associated with a higher incidence of GVHD or interstitial pneumonitis. This observation has led us to consider escalation of the dose of FTBI in our next clinical trial

  1. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations

    Directory of Open Access Journals (Sweden)

    Harman Melinda K

    2012-10-01

    Full Text Available Abstract Background Clinical consequences of alignment errors in total knee replacement (TKR have led to the rigorous evaluation of surgical alignment techniques. Rotational alignment in the transverse plane has proven particularly problematic, with errors due to component malalignment relative to bone anatomic landmarks and an overall mismatch between the femoral and tibial components’ relative positions. Ranges of nominal rotational alignment are not well defined, especially for the tibial component and for relative rotational mismatch, and some studies advocate the use of mobile-bearing TKR to accommodate the resulting small rotation errors. However, the relationships between prosthesis rotational alignment and mobile-bearing polyethylene insert motion are poorly understood. This prospective, in vivo study evaluates whether component malalignment and mismatch affect axial rotation motions during passive knee flexion after TKR. Methods Eighty patients were implanted with mobile-bearing TKR. Rotational alignment of the femoral and tibial components was measured from postoperative CT scans. All TKR were categorized into nominal or outlier groups based on defined norms for surgical rotational alignment relative to bone anatomic landmarks and relative rotational mismatch between the femoral and tibial components. Axial rotation motion of the femoral, tibial and polyethylene bearing components was measured from fluoroscopic images acquired during passive knee flexion. Results Axial rotation motion was generally accomplished in two phases, dominated by polyethylene bearing rotation on the tibial component in early to mid-flexion and then femoral component rotation on the polyethylene articular surface in later flexion. Opposite rotations of the femur-bearing and bearing-baseplate articulations were evident at flexion greater than 80°. Knees with outlier alignment had lower magnitudes of axial rotation and distinct transitions from external to

  2. Measurements of the total-body potassium contents. Application of reference value with the whole-body counter

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tetsuo [Chiba Univ. (Japan). Inst. for Training Radiological Technicians; Saegusa, Kenji; Arimizu, Noboru; Kuniyasu, Yoshio; Itoh, Hisao

    2001-08-01

    The total-body potassium contents were measured in 405 healthy volunteers and 186 patients with whole body counter in Chiba University Hospital. The total-body potassium contents was expressed by the reference value (R value). The R value was calculated as measured potassium contents (g) divided by the body surface area (m{sup 2}) and adjusted by age and sex of healthy persons. The R value was 100.65{+-}9.22% in 405 healthy volunteers. Those of each disease were as follows: liver cirrhosis; 94.24{+-}11.22%, chronic hepatitis; 95.74{+-}11.24%, hyperthyroidism; 99.37{+-}10.8%, periodic paralysis; 82.0{+-}9.01%, Barter's syndrome; 93.99{+-}9.86%, myasthenia gravis; 97.34{+-}6.42% and hypo-potassemia; 90.64{+-}11.76%, respectively. The R values of other diseases such as uterine cancer, breast cancer, anemia, hypertension were 97.78{+-}11.5%, 99.22{+-}8.88%, 96.64{+-}12.73%, 98.5{+-}9.63% respectively. Fourteen patients showed especially lower R values under 75%. These were 1 liver cirrhosis, 3 hypertension, 1 diabetes mellitus, 3 hypo-potassemia, 1 periodic paralysis, 2 Barter's syndrome, 2 chemical poisoning, and 1 breast cancer. Follow-up study was performed in some patients with the lower R values. The result of follow-up study showed that there was a relationship between improvement of symptoms and increase of total body potassium contents. (author)

  3. Effect of aflatoxin ingestion on total body water (T OH3 - space), total body solids A KD on some physiological and reproductive characteristics of male albino rats

    International Nuclear Information System (INIS)

    Nowar, M.S.; Eldarawany, A.A.; Habeeb, A.A.

    1992-01-01

    This investigation aimed to study the effects of aflatoxins B 1 +G 1 mixture mainly on total body water (TBW) and on total body solids (TBS) of male albino rats. Some blood components and some reproductive characteristic were also taken into consideration. Two groups, each of 8 male rats were fed the same ration. Rats of one group had been individually ingested daily with a dose of 22 μg B 1 plus 22 μg G 1 for 15 successive weeks. The obtained results showed that aflatoxin administration caused: 1- A decrease in final body weight (FBW), TBW (P<0.01) and TBS (P<0.05). 2- A decrease in serum total proteins (P<0.01), albumin (P<0.05), globulin (P<0.05), glucose (P<0.05) and increase in serum cholesterol, GOT and GPT (P<0.05) activities. 3- A decrease in each of the number of effective matings of males and delivery percentages of females mated with treated males.1 tab

  4. Physiological joint line total knee arthroplasty designs are especially sensitive to rotational placement - A finite element analysis.

    Science.gov (United States)

    Moewis, Philippe; Checa, Sara; Kutzner, Ines; Hommel, Hagen; Duda, Georg N

    2018-01-01

    Mechanical and kinematical aligning techniques are the usual positioning methods during total knee arthroplasty. However, alteration of the physiological joint line and unbalanced medio-lateral load distribution are considered disadvantages in the mechanical and kinematical techniques, respectively. The aim of this study was to analyse the influence of the joint line on the strain and stress distributions in an implanted knee and their sensitivity to rotational mal-alignment. Finite element calculations were conducted to analyse the stresses in the PE-Inlay and the mechanical strains at the bone side of the tibia component-tibia bone interface during normal positioning of the components and internal and external mal-rotation of the tibial component. Two designs were included, a horizontal and a physiological implant. The loading conditions are based on internal knee joint loads during walking. A medialization of the stresses on the PE-Inlay was observed in the physiological implant in a normal position, accompanied by higher stresses in the mal-rotated positions. Within the tibia component-tibia bone interface, similar strain distributions were observed in both implant geometries in the normal position. However, a medialization of the strains was observed in the physiological implant in both mal-rotated conditions with greater bone volume affected by higher strains. Although evident changes due to mal-rotation were observed, the stresses do not suggest a local plastic deformation of the PE-Inlay. The strains values within most of the tibia component-tibia bone interface were in the physiological strain zone and no significant bone changes would be expected. The physiological cut on the articular aspect showed no detrimental effect compared to the horizontal implant.

  5. Understanding the Influence of Pressure and Radial Loads on Stress and Displacement Response of a Rotating Body: The Automobile Wheel

    Directory of Open Access Journals (Sweden)

    2006-01-01

    Full Text Available This paper highlights the use of the finite element technique for analyzing stress and displacement distributions in wheels of automotive vehicles when subject to the conjoint influence of inflation pressure and radial load. The most commonly used considerations in the design of the rotating body are elucidated. A potentially viable technique for finite element modeling of radial wheel, subjected to loading, is highlighted. The extrinsic influence of inflation pressure on performance of the rotating body, that is, the wheel, is rationalized.

  6. Factors affecting femoral rotational angle based on the posterior condylar axis in gap-based navigation-assisted total knee arthroplasty for valgus knee.

    Science.gov (United States)

    Lee, Sung-Sahn; Lee, Yong-In; Kim, Dong-Uk; Lee, Dae-Hee; Moon, Young-Wan

    2018-01-01

    Achieving proper rotational alignment of the femoral component in total knee arthroplasty (TKA) for valgus knee is challenging because of lateral condylar hypoplasia and lateral cartilage erosion. Gap-based navigation-assisted TKA enables surgeons to determine the angle of femoral component rotation (FCR) based on the posterior condylar axis. This study evaluated the possible factors that affect the rotational alignment of the femoral component based on the posterior condylar axis. Between 2008 and 2016, 28 knees were enrolled. The dependent variable for this study was FCR based on the posterior condylar axis, which was obtained from the navigation system archives. Multiple regression analysis was conducted to identify factors that might predict FCR, including body mass index (BMI), Kellgren-Lawrence grade (K-L grade), lateral distal femoral angles obtained from the navigation system and radiographs (NaviLDFA, XrayLDFA), hip-knee-ankle (HKA) axis, lateral gap under varus stress (LGVS), medial gap under valgus stress (MGVS), and side-to-side difference (STSD, MGVS - LGVS). The mean FCR was 6.1° ± 2.0°. Of all the potentially predictive factors evaluated in this study, only NaviLDFA (β = -0.668) and XrayLDFA (β = -0.714) predicted significantly FCR. The LDFAs, as determined using radiographs and the navigation system, were both predictive of the rotational alignment of the femoral component based on the posterior condylar axis in gap-based TKA for valgus knee. A 1° increment with NaviLDFA led to a 0.668° decrement in FCR, and a 1° increment with XrayLDFA led to a 0.714° decrement. This suggests that symmetrical lateral condylar hypoplasia of the posterior and distal side occurs in lateral compartment end-stage osteoarthritis with valgus deformity.

  7. Measurement of total-body oxygen, nitrogen, and carbon in vivo by photon activation analysis

    International Nuclear Information System (INIS)

    Ulin, K.

    1984-01-01

    With the aim of assessing nutritional status, the feasibility of measuring the total body quantities of the major body elements, i.e. oxygen, nitrogen, and carbon, using the photon beam of a 45 MV betatron and a whole-body counter, has been evaluated in detail. Following photon activation a single energy γ-radiation (.511 MeV) is observed from all three elements to be measured. The half-lives of 15 O, 13 N, and 11 C, however, are sufficiently different (20.5 min, 10.0 min, and 20.4 min. respectively) to permit their measurement from an analysis of the measured decay curve. Following corrections for interfering reactions, a computer curve-fitting algorithm is used to resolve the data into 15 O, 13 N, and 11 C components. Measurements of O, N, and C have been made both in phantoms and in live and dead rats. A comparison of the body composition results from this technique with results from chemical analysis indicates that measured carbon can quite accurately predict total body fat. The comparison of the total body nitrogen measurement by photon activation with total body protein by chemical analysis was inconclusive and suggests that further work be done to verify the estimated accuracy of the nitrogen measurement

  8. Investigation into the relationship between body surface area and total body potassium using Monte Carlo and measurement

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, J.A. [Medical Physics and Imaging, Queen Elizabeth Hospital, Birmingham (United Kingdom)]. E-mail: jane.rogers@university-b.wmids.nhs.uk; Blake-James, M. [School of Physics and Astronomy, University of Birmingham, Birmingham (United Kingdom); Green, S.; Beddoe, A.H. [Medical Physics and Imaging, Queen Elizabeth Hospital, Birmingham (United Kingdom)

    2002-03-07

    The use of body surface area (BSA) as a means of indexing chemotherapy doses is widespread even though the value of this practice is uncertain. In principle, the body cell mass (BCM) more closely represents the body's metabolic size and this is investigated here as an alternative to BSA; since 98% of body potassium is intracellular the derivation of total body potassium (TBK) via the measurement of {sup 40}K in a whole body counter (WBC) will provide a useful normalizing index for metabolic size, potentially avoiding toxicity and underdosing. The Queen Elizabeth Hospital WBC has been used in this study, initially involving single geometrical phantoms and then combinations of these to simulate human body habitus. Monte Carlo N-particle (MCNP) codes were constructed to model the phantoms and simulate the measurements made in the WBC. Efficiency corrections were derived by comparing measurement and modelled data for each detector separately. A method of modelling a person in the WBC as a series of ellipsoids was developed. Twenty-four normal males and 24 females were measured for their {sup 40}K emissions. Individual MCNP codes were constructed for each volunteer and the results used in conjunction with the measurements to derive TBK, correcting for body habitus effects and detector efficiencies. An estimate of the component of error arising from sources other than counting statistics was included by analysing data from the measurement of phantoms. The total residual errors (expressed as coefficients of variation) for males and females were 10.1% and 8.5% respectively. The measurement components were determined to be 2.4% and 2.5%, implying that the biological components were 9.8% and 8.1% respectively. These results suggest that the use of BSA for indexing chemotherapy doses is likely to give rise to clinically significant under- or overdosing. (author)

  9. Quantitation of the degree of osteoporosis by measure of total-body calcium employing neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Zanzi, I.; Vaswani, A.; Wallach, S.; Aloia, J.; Ellis, K.J.

    1975-01-01

    Two techniques for measuring the amount of Ca in the total skeleton were employed: total-body neutron activation analysis (TBNAA) and the determination of the mineral content of a bone of the appendicular skeleton (absorptiometric measurement of the radius, BMC). (U.S.)

  10. The role of Tl-201 total body scintigraphy in follow up of thyroid carcinoma

    International Nuclear Information System (INIS)

    Hoefnagel, C.A.; Delprat, C.C.; Marcuse, H.R.

    1985-01-01

    To evaluate the reliability of the procedure T1-201 total body scintigraphy was performed in 294 patients (449 studies) after total thyroidectomy for thyroid carcinoma. Results were correlated with I-131-scintigraphy and tumor-marker levels (Tgb or Calcitonin/CEA). T1-201 total body scintigraphy was negative in 196 patients with no evidence of disease. T1-201-scintigraphy correctly detected tumor localizations in 24 of 30 patients with I-131-positive metastases. In 28 patients T2-201 total body scintigraphy revealed metastases which did not concentrate I-131. Histology/cytology confirmed thyroid carcinoma metastases in 16 patients and other pathology in 5 cases. 9 of 18 patients with medullary thyroid carcinoma (I-131-negative) had elevated Calcitonin/CEA-levels. The T1-201 scintigram was positive in 8 of these patients. Comparison of T1-201, I-131 and tumor markers showed that only combined use of these parameters provide complete reliability. The authors conclude that T1-201 total body scintigraphy is useful in follow up of thyroid carcinoma, especially when a discrepancy of the other parameters exists and particularly in medullary carcinoma. In long term follow up of patients who are unsuspected of disease after successful therapy for thyroid carcinoma one can rely on T1-201 total body scintigraphy in combination with tumor marker assays

  11. Perception of self motion during and after passive rotation of the body around an earth-vertical axis.

    Science.gov (United States)

    Sinha, N; Zaher, N; Shaikh, A G; Lasker, A G; Zee, D S; Tarnutzer, A A

    2008-01-01

    We investigated the perception of self-rotation using constant-velocity chair rotations. Subjects signalled self motion during three independent tasks (1) by pushing a button when rotation was first sensed, when velocity reached a peak, when velocity began to decrease, and when velocity reached zero, (2) by rotating a disc to match the perceived motion of the body, or (3) by changing the static position of the dial such that a bigger change in its position correlated with a larger perceived velocity. All three tasks gave a consistent quantitative measure of perceived angular velocity. We found a delay in the time at which peak velocity of self-rotation was perceived (2-5 s) relative to the beginning or to the end of chair rotation. In addition the decay of the perception of self-rotation was preceded by a sensed constant-velocity interval or plateau (9-14 s). This delay in the rise of self-motion perception, and the plateau for the maximum perceived velocity, contrasts with the rapid rise and the immediate decay of the angular vestibuloocular reflex (aVOR). This difference suggests that the sensory signal from the semicircular canals undergoes additional neural processing, beyond the contribution of the velocity-storage mechanism of the aVOR, to compute the percept of self-motion.

  12. Clinical Perspective of 3D Total Body Photography for Early Detection and Screening of Melanoma.

    Science.gov (United States)

    Rayner, Jenna E; Laino, Antonia M; Nufer, Kaitlin L; Adams, Laura; Raphael, Anthony P; Menzies, Scott W; Soyer, H Peter

    2018-01-01

    Melanoma incidence continues to increase across many populations globally and there is significant mortality associated with advanced disease. However, if detected early, patients have a very promising prognosis. The methods that have been utilized for early detection include clinician and patient skin examinations, dermoscopy (static and sequential imaging), and total body photography via 2D imaging. Total body photography has recently witnessed an evolution from 2D imaging with the ability to now create a 3D representation of the patient linked with dermoscopy images of individual lesions. 3D total body photography is a particularly beneficial screening tool for patients at high risk due to their personal or family history or those with multiple dysplastic naevi-the latter can make monitoring especially difficult without the assistance of technology. In this perspective, we discuss clinical examples utilizing 3D total body photography, associated advantages and limitations, and future directions of the technology. The optimal system for melanoma screening should improve diagnostic accuracy, be time and cost efficient, and accessible to patients across all demographic and socioeconomic groups. 3D total body photography has the potential to address these criteria and, most importantly, optimize crucial early detection.

  13. Measurements of the total-body potassium contents. Application of reference value with the whole-body counter

    International Nuclear Information System (INIS)

    Yamamoto, Tetsuo; Saegusa, Kenji; Arimizu, Noboru; Kuniyasu, Yoshio; Itoh, Hisao

    2001-01-01

    The total-body potassium contents were measured in 405 healthy volunteers and 186 patients with whole body counter in Chiba University Hospital. The total-body potassium contents was expressed by the reference value (R value). The R value was calculated as measured potassium contents (g) divided by the body surface area (m 2 ) and adjusted by age and sex of healthy persons. The R value was 100.65±9.22% in 405 healthy volunteers. Those of each disease were as follows: liver cirrhosis; 94.24±11.22%, chronic hepatitis; 95.74±11.24%, hyperthyroidism; 99.37±10.8%, periodic paralysis; 82.0±9.01%, Barter's syndrome; 93.99±9.86%, myasthenia gravis; 97.34±6.42% and hypo-potassemia; 90.64±11.76%, respectively. The R values of other diseases such as uterine cancer, breast cancer, anemia, hypertension were 97.78±11.5%, 99.22±8.88%, 96.64±12.73%, 98.5±9.63% respectively. Fourteen patients showed especially lower R values under 75%. These were 1 liver cirrhosis, 3 hypertension, 1 diabetes mellitus, 3 hypo-potassemia, 1 periodic paralysis, 2 Barter's syndrome, 2 chemical poisoning, and 1 breast cancer. Follow-up study was performed in some patients with the lower R values. The result of follow-up study showed that there was a relationship between improvement of symptoms and increase of total body potassium contents. (author)

  14. THE ATHLETES’ BODY SHAPES THE ATHLETES’ MIND – NEW PERSPECTIVES ON MENTAL ROTATION PERFORMANCE IN ATHLETES

    Directory of Open Access Journals (Sweden)

    Thomas Heinen

    2013-12-01

    Full Text Available Mentally rotating the image of an object is one fundamental cognitive ability in humans. Recent theoretical developments and empirical evidences highlight the potential role of the sensory-motor system, when analysing and understanding mental rotation. Therefore, the purpose of this study was to investigate the role of specific sensory-motor experience on mental rotation performance in gymnasts. N = 40 male gymnasts with either clockwise or anticlockwise rotation preference in a forward twisting layout salto performed a psychometric mental rotation test with either rotation-preference congruent or rotation-preference incongruent stimuli. Results revealed that choice reaction times differed clearly as a function of Angular Rotation between the stimuli figures. Gymnasts who preferred a clockwise rotation preference showed faster choice reaction times when the rotation direction of the reference figure was clockwise, and vice versa. The results clearly support the notion, that mental rotation performance varies as a function of sensory-motor system characteristics between different people. It is concluded, that sensory-motor experience in a particular sport may facilitate cognitive processing of experience-congruent stimuli. This may be advantageous for situations in which people are engaged in observing sport performance (i.e., judges, coaches. This conclusion could furthermore contribute to the training of athletes from sports such as sky-diving, scuba-diving, and climbing, where losses of spatial orientation can be life-threatening.

  15. Measurement of total body chlorine by prompt gamma in vivo neutron activation analysis

    International Nuclear Information System (INIS)

    Beddoe, A.H.; Streat, S.J.; Hill, G.L.

    1987-01-01

    A method of measuring total body chlorine (TBCl) by prompt gamma in vivo neutron activation analysis is described depending on the same NaI(Tl) spectra used for determinations of total body nitrogen. Ratios of chlorine to hydrogen are derived and TBCl determined using a model of body composition depending on measured body weight, total body water (by tritium dilution) and protein (6.25 x nitrogen) as well as estimated body minerals and glycogen. The precision of the method based on scanning an anthropomorphic phantom is approximately 9% (SD), for a patient dose equivalent of less than 0.30 mSv. Spectra collected from 67 normal volunteers (32 male, 35 female) yielded mean values of TBCl of 72 +- 19 (SD) g in males and 53.6 +- 15 g in females, in broad agreement with values reported by workers using delayed gamma methods. Results are presented for two human cadavers analysed by neutron activation and conventional chemical analysis; the ratios of TBCl (neutron activation) to TBCl (chemical) were 0.980 +- 0.028 (SEM) and 0.91 +- 0.09. It is suggested that an improvement in precision will be achieved by increasing the scanning time (thereby increasing the radiation dose equivalent) and by adding two more detectors. (author)

  16. Total body skeletal muscle mass: estimation by creatine (methyl-d3) dilution in humans

    Science.gov (United States)

    Walker, Ann C.; O'Connor-Semmes, Robin L.; Leonard, Michael S.; Miller, Ram R.; Stimpson, Stephen A.; Turner, Scott M.; Ravussin, Eric; Cefalu, William T.; Hellerstein, Marc K.; Evans, William J.

    2014-01-01

    Current methods for clinical estimation of total body skeletal muscle mass have significant limitations. We tested the hypothesis that creatine (methyl-d3) dilution (D3-creatine) measured by enrichment of urine D3-creatinine reveals total body creatine pool size, providing an accurate estimate of total body skeletal muscle mass. Healthy subjects with different muscle masses [n = 35: 20 men (19–30 yr, 70–84 yr), 15 postmenopausal women (51–62 yr, 70–84 yr)] were housed for 5 days. Optimal tracer dose was explored with single oral doses of 30, 60, or 100 mg D3-creatine given on day 1. Serial plasma samples were collected for D3-creatine pharmacokinetics. All urine was collected through day 5. Creatine and creatinine (deuterated and unlabeled) were measured by liquid chromatography mass spectrometry. Total body creatine pool size and muscle mass were calculated from D3-creatinine enrichment in urine. Muscle mass was also measured by magnetic resonance imaging (MRI), dual-energy x-ray absorptiometry (DXA), and traditional 24-h urine creatinine. D3-creatine was rapidly absorbed and cleared with variable urinary excretion. Isotopic steady-state of D3-creatinine enrichment in the urine was achieved by 30.7 ± 11.2 h. Mean steady-state enrichment in urine provided muscle mass estimates that correlated well with MRI estimates for all subjects (r = 0.868, P creatine dose determined by urine D3-creatinine enrichment provides an estimate of total body muscle mass strongly correlated with estimates from serial MRI with less bias than total lean body mass assessment by DXA. PMID:24764133

  17. Vestibuloocular reflex dynamics during high-frequency and high-acceleration rotations of the head on body in rhesus monkey.

    Science.gov (United States)

    Huterer, Marko; Cullen, Kathleen E

    2002-07-01

    For frequencies >10 Hz, the vestibuloocular reflex (VOR) has been primarily investigated during passive rotations of the head on the body in humans. These prior studies suggest that eye movements lag head movements, as predicted by a 7-ms delay in the VOR reflex pathways. However, Minor and colleagues recently applied whole-body rotations of frequencies unity (1.1 at 5 Hz vs. 1.2 at 25 Hz), and phase lag increased only slightly with frequency (from 2 degrees at 5 Hz to 11 degrees at 25 Hz, a marked contrast to the 63 degrees lag at 25 Hz predicted by a 7-ms VOR latency). Furthermore, VOR response dynamics were comparable in darkness and when viewing a target and did not vary with peak velocity. Although monkeys offered less resistance to the initial cycles of applied head motion, the gain and phase of the VOR did not vary for early versus late cycles, suggesting that an efference copy of the motor command to the neck musculature did not alter VOR response dynamics. In addition, VOR dynamics were also probed by applying transient head perturbations with much greater accelerations (peak acceleration >15,000 degrees /s(2)) than have been previously employed. The VOR latency was between 5 and 6 ms, and mean gain was close to unity for two of the three animals tested. A simple linear model well described the VOR responses elicited by sinusoidal and transient head on body rotations. We conclude that the VOR is compensatory over a wide frequency range in monkeys and has similar response dynamics during passive rotation of the head on body as during passive rotation of the whole body in space.

  18. Kinetics of total body retention and clearance of xenon and krypton after inhalation

    International Nuclear Information System (INIS)

    Susskind, H.; Atkins, H.L.; Cohn, S.H.; Ellis, K.J.; Richards, P.

    1976-01-01

    The total body retention of Xe-127 and Kr-79 and their clearance rates following inhalation were measured in vivo. These data are useful for refined Xe-127 dosimetry calculations, to determine the potential radiation hazard of fission product Kr-85, and more generally to study the behavior of anesthetic gases. While data are available on the solubilities and partition coefficients of Xe and Kr in fat, blood, and other individual body constituents, few measurements of their retention and clearance from the entire body have been reported

  19. Spontaneous resolution of posterior ankle joint loose bodies after total ankle replacement: A case report.

    Science.gov (United States)

    Lee, Raymond P; Cheng, Sally H S

    2017-06-01

    Late stage ankle osteoarthritis often presents with debilitating pain. It is common to find osteophytes and loose body formation around the joint. Total ankle arthroplasty can preserve joint mobility and pain relieve for such patient. However, when trying to remove the osteophytes and loose bodies at the posterior ankle joint, there is risk of damaging posterior structures such as the neurovascular bundle during the procedure. We are presenting a case where the posterior loose bodies remained untouched during the operation, and patient showed spontaneous resolution of the lesions with time. Patient enjoyed good function outcome after the surgery. Copyright © 2016 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  20. Rotation of quantum impurities in the presence of a many-body environment

    Science.gov (United States)

    Lemeshko, Mikhail; Schmidt, Richard

    2015-05-01

    Pioneered by the seminal works of Wigner and Racah, the quantum theory of angular momentum evolved into a powerful machinery, commonly used to classify the states of isolated quantum systems and perturbations to their structure due to electromagnetic or crystalline fields. In ``realistic'' experiments, however, quantum systems are almost inevitably coupled to a many-particle environment and a field of elementary excitations associated with it, which is capable of fundamentally altering the physics of the system. We present the first systematic treatment of quantum rotation coupled to a many-particle environment. By using a series of canonical transformations on a generic microscopic Hamiltonian, we single out the conserved quantities of the problem. Using a variational ansatz accounting for an infinite number of many-body excitations, we characterize the spectrum of angular momentum eigenstates and identify the regions of instability, accompanied by emission of angular Cerenkov radiation. The developed technique can be applied to a wide range of systems described by the angular momentum algebra, from Rydberg atoms immersed into BEC's, to cold molecules solvated in helium droplets, to ultracold molecular ions.

  1. Radiation nephritis following total-body irradiation and cyclophosphamide in preparation for bone marrow transplantation

    International Nuclear Information System (INIS)

    Bergstein, J.; Andreoli, S.P.; Provisor, A.J.; Yum, M.

    1986-01-01

    Two children prepared for bone marrow transplantation with total-body irradiation and cyclophosphamide developed hypertension, microscopic hematuria, proteinuria, diminished renal function, and anemia six months after transplantation. Light microscopy of the kidneys revealed mesangial expansion, glomerular capillary wall thickening, and lumenal thrombosis. Electron microscopy demonstrated widening of the subendothelial space due to the deposition of amorphous fluffy material. In one patient, immunofluorescence microscopy revealed glomerular capillary wall deposition of fibrin and immunoglobulins. The clinical and histologic findings support the diagnosis of radiation nephritis. Patients prepared for bone marrow transplantation with total-body irradiation and cyclophosphamide should be followed closely after transplantation for the development of hypertension, proteinuria, and renal insufficiency

  2. In vivo Prompt Gamma Neutron Activation Analysis Facility for Total Body Nitrogen and Cd

    International Nuclear Information System (INIS)

    Munive, Marco; Revilla, Angel; Solis, Jose L.

    2007-01-01

    A Prompt Gamma Neutron Activation Analysis (PGNAA) system has been designed and constructed to measure the total body nitrogen and Cd for in vivo studies. An aqueous solution of KNO 3 was used as phantom for system calibration. The facility has been used to monitor total body nitrogen (TBN) of mice and found that is related to their diet. Some mice swallowed diluted water with Cl 2 Cd, and the presence of Cd was detected in the animals. The minimum Cd concentration that the system can detect was 20 ppm

  3. Total Body Photography as an Aid to Skin Self-examination: A Patient's Perspective.

    Science.gov (United States)

    Secker, Lisanne J; Bergman, Wilma; Kukutsch, Nicole A

    2016-02-01

    Skin self-examination can help patients who are at high risk for developing melanoma to become more involved in their own surveillance and treatment. This study examined the use of total body photography as an aid to skin self-examination from the patients' perspective. A total of 179 individuals at high risk for developing melanoma who had undergone total body photography (60.5% response rate) completed a self-reported questionnaire assessing the frequency of skin self-examination, perceived usefulness of total body photography, and a variety of potential demographic, clinical and psychological factors. Only approximately half of the participants indicated skin self-examination as useful and 78.9% preferred clinical skin examination by a specialist. Finding total body photography useful was associated with having received instructions on how to perform skin self-examination, the use of a (hand)mirror, and confidence to detect changing moles. These findings allow us to develop strategies to further improve patients' self-screening behaviours.

  4. EXPLORER: Changing the molecular imaging paradigm with total-body PET/CT (Conference Presentation)

    Science.gov (United States)

    Cherry, Simon R.; Badawi, Ramsey D.; Jones, Terry

    2016-04-01

    Positron emission tomography (PET) is the highest sensitivity technique for human whole-body imaging studies. However, current clinical PET scanners do not make full use of the available signal, as they only permit imaging of a 15-25 cm segment of the body at one time. Given the limited sensitive region, whole-body imaging with clinical PET scanners requires relatively long scan times and subjects the patient to higher than necessary radiation doses. The EXPLORER initiative aims to build a 2-meter axial length PET scanner to allow imaging the entire subject at once, capturing nearly the entire available PET signal. EXPLORER will acquire data with ~40-fold greater sensitivity leading to a six-fold increase in reconstructed signal-to-noise ratio for imaging the total body. Alternatively, total-body images with the EXPLORER scanner will be able to be acquired in ~30 seconds or with ~0.15 mSv injected dose, while maintaining current PET image quality. The superior sensitivity will open many new avenues for biomedical research. Specifically for cancer applications, high sensitivity PET will enable detection of smaller lesions. Additionally, greater sensitivity will allow imaging out to 10 half-lives of positron emitting radiotracers. This will enable 1) metabolic ultra-staging with FDG by extending the uptake and clearance time to 3-5 hours to significantly improve contrast and 2) improved kinetic imaging with short-lived radioisotopes such as C-11, crucial for drug development studies. Frequent imaging studies of the same subject to study disease progression or to track response to therapy will be possible with the low dose capabilities of the EXPLORER scanner. The low dose capabilities will also open up new imaging possibilities in pediatrics and adolescents to better study developmental disorders. This talk will review the basis for developing total-body PET, potential applications, and review progress to date in developing EXPLORER, the first total-body PET scanner.

  5. Monte Carlo efficiency calibration of a neutron generator-based total-body irradiator

    International Nuclear Information System (INIS)

    Shypailo, R.J.; Ellis, K.J.

    2009-01-01

    Many body composition measurement systems are calibrated against a single-sized reference phantom. Prompt-gamma neutron activation (PGNA) provides the only direct measure of total body nitrogen (TBN), an index of the body's lean tissue mass. In PGNA systems, body size influences neutron flux attenuation, induced gamma signal distribution, and counting efficiency. Thus, calibration based on a single-sized phantom could result in inaccurate TBN values. We used Monte Carlo simulations (MCNP-5; Los Alamos National Laboratory) in order to map a system's response to the range of body weights (65-160 kg) and body fat distributions (25-60%) in obese humans. Calibration curves were constructed to derive body-size correction factors relative to a standard reference phantom, providing customized adjustments to account for differences in body habitus of obese adults. The use of MCNP-generated calibration curves should allow for a better estimate of the true changes in lean tissue mass that many occur during intervention programs focused only on weight loss. (author)

  6. Can tritiated water-dilution space accurately predict total body water in chukar partridges

    International Nuclear Information System (INIS)

    Crum, B.G.; Williams, J.B.; Nagy, K.A.

    1985-01-01

    Total body water (TBW) volumes determined from the dilution space of injected tritiated water have consistently overestimated actual water volumes (determined by desiccation to constant mass) in reptiles and mammals, but results for birds are controversial. We investigated potential errors in both the dilution method and the desiccation method in an attempt to resolve this controversy. Tritiated water dilution yielded an accurate measurement of water mass in vitro. However, in vivo, this method yielded a 4.6% overestimate of the amount of water (3.1% of live body mass) in chukar partridges, apparently largely because of loss of tritium from body water to sites of dissociable hydrogens on body solids. An additional source of overestimation (approximately 2% of body mass) was loss of tritium to the solids in blood samples during distillation of blood to obtain pure water for tritium analysis. Measuring tritium activity in plasma samples avoided this problem but required measurement of, and correction for, the dry matter content in plasma. Desiccation to constant mass by lyophilization or oven-drying also overestimated the amount of water actually in the bodies of chukar partridges by 1.4% of body mass, because these values included water adsorbed onto the outside of feathers. When desiccating defeathered carcasses, oven-drying at 70 degrees C yielded TBW values identical to those obtained from lyophilization, but TBW was overestimated (0.5% of body mass) by drying at 100 degrees C due to loss of organic substances as well as water

  7. Comparison of nodal staging with lean body mass based and with total body weight based in lung cancer

    International Nuclear Information System (INIS)

    Lee, H. Y.; Chung, J. K.; Kang, W. J.; So, Y.; Lee, D. S.; Lee, M. C.

    2004-01-01

    The standardized uptake (SUV) is semiquantitative evaluation parameter in positron emission tomography (PET). But there is no consensus about the application or process of SUV measurement. In this study, we used measured lean body mass (LBM) and total weight for application in SUV measurement. Also we compared the each nodal staging with SUV between measured LBM, and total weight, in non small cell lung cancer (NSCLC). Total 21 patients with lung cancer were enrolled (M:F=17:4, age 45[+-]8 years). PET-CT was done before operation with Gemini (Philips, Milpitas, U.S.). Each image was reconstructed twice with measured weight and lean body mass. Maximum SUVs of 103 dissected lymph nodes were measured and compared with histological result. For the deciding on the cut off value, receiver operating characteristic (ROC) analysis was done. 14 lymph nodes in the 103 dissected lymph nodes were metastatic lesions. From the ROC analysis, the cut off value of SUV was 1.7 with measured LBM and 2.3 with total weight. With measured LBM, Sensitivity and specificity were 92.5%. 78.2% and area under curve was 0.881. With total weight, sensitivity and specificity was 92.5% and 77%, Area under curve was 0.859. The normalization of SUV could be done with measured LBM. With the normalization of SUV with LBM, the nodal staging of NSCLC using SUV could be more accurate than using total weight in the reconstruction and measurement of SUV for lymph node lesions

  8. Effects of Zinc Compound on Body Weight and Recovery of Bone Marrow in Mice Treated with Total Body Irradiation

    Directory of Open Access Journals (Sweden)

    Ming-Yii Huang

    2007-09-01

    Full Text Available This study aimed to investigate if zinc compound would have effects on body weight loss and bone marrow suppression induced by total body irradiation (TBI. ICR mice were divided randomly into two groups and treated with test or control compounds. The test compound contained zinc (amino acid chelated with bovine prostate extract, and the control was reverse osmosis pure water (RO water. One week after receiving the treatment, mice were unirradiated, or irradiated with 6 or 3 Gy by 6MV photon beams to the total body. Body weight changes were examined at regular intervals. Three and 5 weeks after the radiation, animals were sacrificed to examine the histologic changes in the bone marrow. Lower body weight in the period of 1-5 weeks after radiation and poor survival rate were found after the 6 Gy TBI, as compared with the 3 Gy groups. The median survival time after 6 Gy and 3 Gy TBI for mice given the test compound were 26 and 76 days, respectively, and the corresponding figures were 14 and 70 days, respectively, for mice given the control compound (p < 0.00001. With zinc supplement, the mean body weight in mice which received the same dose of radiation was 7-8 g heavier than in the water-supplement groups during the second and third weeks (p < 0.05. Hence, there was no statistically significant difference in survival rate between zinc and water supplement in mice given the same dose of irradiation. Histopathologically there was less recovery of bone marrow cells in the 6Gy groups compared with the 3Gy groups. In the 3 Gy water-supplement group, the nucleated cells and megakaryocytes were recovered in the fifth week when recovery was still not seen in the 6Gy group. With zinc supplement, these cells were recovered in the third week. In this study, we found that zinc is beneficial to body weight in mice treated with TBI. Histologic examination of bone marrow showed better recovery of bone marrow cells in groups of mice fed with zinc. This study

  9. Total body irradiation and marrow transplantation for acute leukaemia. The Royal Marsden Hospital experience

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, A; Barrett, A J; Powles, R L [Institute of Cancer Research, Sutton (UK). Surrey Branch; Royal Marsden Hospital, London (UK))

    1979-06-01

    The experience with total body irradiation at the Royal Marsden Hospital is described for an elective program of transplantation in patients with acute myeloid leukaemia (AML) in first remission. Dose rate appears to be a critical factor in the reduction of radiation-associated damage and careful monitoring of the actual dose distribution and dose received is mandatory.

  10. Post-laryngectomy localization of I-131 at tracheostomy site on a total body scan

    International Nuclear Information System (INIS)

    Kirk, G.A.; Schulz, E.E.

    1984-01-01

    A post-thyroidectomy, post-I-131-therapy patient had a laryngectomy and neck dissection for recurrent papillary thyroid carcinoma. A subsequent I-131 total body scan revealed persistent anterior neck activity, which disappeared upon removal of the tracheostomy tube and dressings

  11. A Large Rice Body-Containing Cyst Mimicking Infection following Total Hip Arthroplasty: A Case Report

    Directory of Open Access Journals (Sweden)

    Wael Bayoud

    2017-01-01

    Full Text Available Introduction. Soft tissue mass following total hip arthroplasty raises several differential diagnoses not limited to infection, hematoma, wear debris, malignancy, and bursitis. Rice body formation in the hip region is an uncommon process denoting a chronic inflammation. We report here the second case of its kind in the medical literature of a wide symptomatic rice-like body cyst complicating a total hip arthroplasty. Case Presentation. This is the case of an 82-year-old white female, presenting with a warm, red, and inflated groin five years after revision of right total hip arthroplasty. Surgical intervention reveals a large well circumscribed cyst containing well-organized rice-like bodies. This eventuality was never reported in differential diagnosis of hip periprosthetic soft tissue masses before. Conclusion. This case report helps widening the array of the differential diagnosis in patients presenting with a slow growing soft tissue mass following total hip arthroplasty, making rice-like bodies cyst a valid one to consider.

  12. Dosimetry for total body irradiation of rhesus monkeys with 300 kV X- rays

    NARCIS (Netherlands)

    Zoetelief, J.; Wagemaker, G.; Broerse, J.J.

    1998-01-01

    Purpose: To obtain more accurate information on the dose distribution in rhesus monkeys for total body irradiation with orthovoltage X-rays. Materials and methods: Dose measurements were performed with an ionization chamber inside homogeneous cylindrical and rectangular phantoms of various

  13. Comparative evolution of coagulation disorders in baboons and Pigs after total body irradiation

    International Nuclear Information System (INIS)

    Destombe, C.; Lefleche, P.; Veyret, J.; Grasseau, A.; Agay, D.; Mestries, J.C.

    1994-01-01

    Acute total body irradiation in pigs, with a lethal dose of either gamma or mixed gamma-neutron radiation, induced similar plasmatic coagulation disorders as those observed in baboons. These data validated pathophysiological hypothesis which were developed during previous studies, but do not support the idea of a possible species specific radiosensitivity. (author)

  14. Total body topical 5-fluorouracil for extensive non-melanoma skin cancer

    NARCIS (Netherlands)

    van Ruth, Serge; Jansman, Frank G. A.; Sanders, Cornelis J.

    Background Topical 5-fluorouracil 5% cream is one of the treatment modalities for non-melanoma skin cancer (NMSC). There is a lack of suitable therapies to treat patients with extensive NMSC. In this paper we report two patients with extensive NMSC treated by total body application of topical

  15. Whole-body irradiation technique: physical aspects; Tecnica de irradiacion corporal total: aspectos fisicos

    Energy Technology Data Exchange (ETDEWEB)

    Venencia, D.; Bustos, S.; Zunino, S. [Instituto Privado de Radioterapia. Obispo Oro 425. Cordoba 5000 (Argentina)

    1998-12-31

    The objective of this work has been to implement a Total body irradiation technique that fulfill the following conditions: simplicity, repeatability, fast and comfortable positioning for the patient, homogeneity of the dose between 10-15 %, short times of treatments and In vivo dosimetric verifications. (Author)

  16. Age, gender, and race/ethnic differences in total body and subregional bone density.

    Science.gov (United States)

    Looker, A C; Melton, L J; Harris, T; Borrud, L; Shepherd, J; McGowan, J

    2009-07-01

    Total body bone density of adults from National Health and Nutrition Examination Survey (NHANES) 1999-2004 differed as expected for some groups (men>women and blacks>whites) but not others (whites>Mexican Americans). Cross-sectional age patterns in bone mineral density (BMD) of older adults differed at skeletal sites that varied by degree of weight-bearing. Total body dual-energy X-ray absorptiometry (DXA) data offer the opportunity to compare bone density of demographic groups across the entire skeleton. The present study uses total body DXA data (Hologic QDR 4500A, Hologic, Bedford MA, USA) from the NHANES 1999-2004 to examine BMD of the total body and selected skeletal subregions in a wide age range of adult men and women from three race/ethnic groups. Total body, lumbar spine, pelvis, right leg, and left arm BMD and lean mass from 13,091 adults aged 20 years and older were used. The subregions were chosen to represent sites with different degrees of weight-bearing. Mean BMD varied in expected ways for some demographic characteristics (men>women and non-Hispanic blacks>non-Hispanic whites) but not others (non-Hispanic whites>Mexican Americans). Differences in age patterns in BMD also emerged for some characteristics (sex) but not others (race/ethnicity). Differences in cross-sectional age patterns in BMD and lean mass by degree of weight-bearing in older adults were observed for the pelvis, leg, and arm. This information may be useful for generating hypotheses about age, race, and sex differences in fracture risk in the population.

  17. TH-EF-BRB-09: Total Body Irradiation with Uniform MU and Modulated Arc Segments, UMMS-TBI

    Energy Technology Data Exchange (ETDEWEB)

    Yi, B; Chung, H; Mutaf, Y; Prado, K [University of Maryland School of Medicine, Baltimore, MD (United States)

    2016-06-15

    Purpose: To test a novel total body irradiation (TBI) system using conformal partial arc with patient lying on the stationary couch which is biologically equivalent to a moving couch TBI. This improves the scanning field TBI, which is previously presented. Methods: The Uniform MU Modulated arc Segments TBI or UMMS-TBI scans the treatment plane with a constant machine dose rate and a constant gantry rotation speed. A dynamic MLC pattern which moves while gantry rotates has been designed so that the treatment field moves same distance at the treatment plane per each gantry angle, while maintaining same treatment field size (34cm) at the plane. Dose across the plane varies due to the geometric differences including the distance from the source to a point of interest and the different attenuation from the slanted depth which changes the effective depth. Beam intensity is modulated to correct the dose variation across the plane by assigning the number of gantry angles inversely proportional to the uncorrected dose. Results: Measured dose and calculated dose matched within 1 % for central axis and 3% for off axis for various patient scenarios. Dose from different distance does not follow the inverse square relation as it is predicted from calculation. Dose uniformity better than 5% across 180 cm at 10cm depth is achieved by moving the gantry from −55 to +55 deg. Total treatment time for 2 Gy AP/PA fields is 40–50 minutes excluding patient set up time, at the machine dose rate of 200 MU/min. Conclusion: This novel technique, yet accurate but easy to implement enables TBI treatment in a small treatment room with less program development preparation than other techniques. The VMAT function of treatment delivery is not required to modulate beams. One delivery pattern can be used for different patients by changing the monitor units.

  18. Skeletal and total body volumes of human fetuses: assessment of reference data by spiral CT

    International Nuclear Information System (INIS)

    Braillon, Pierre M.; Buenerd, Annie; Bouvier, Raymonde; Lapillonne, Alexandre

    2002-01-01

    Objective: To define reference data for skeletal and total body volumes of normal human fetuses. Materials and methods: Spiral CT was used to assess the skeletal and total body volumes of 31 normal human stillborn infants with gestational age (GA) and body weight (BW) ranging from 14 to 41.5 weeks and 22 to 3,760 g, respectively. CT scans (slice thickness 2.7 mm, pitch 0.7) were performed within the first 24 h after delivery. Precise bone and soft-tissue windows were defined from analysis of the density along the diaphysis of the fetal long bones and from the measurement of a phantom that mimics soft tissues. Lengths and volumes were obtained from 3D reconstructions. The femur lengths measured from CT images (FLct) were compared with those provided by US studies (FLus). Results: Significant correlations (r>0.9) were found between BW, measured volumes of the entire skeleton or head, long-bone lengths, biparietal diameter and GA. Strong linear correlations (r>0.98) were observed between FLct and FLus. Conclusions: Skeletal and total body volume values obtained using spiral CT were significantly correlated with fetal biometric measurements. These data could complement those obtained in obstetric investigations with US. (orig.)

  19. Dose calculation method with 60-cobalt gamma rays in total body irradiation

    International Nuclear Information System (INIS)

    Scaff, Luiz Alberto Malaguti

    2001-01-01

    Physical factors associated to total body irradiation using 60 Co gamma rays beams, were studied in order to develop a calculation method of the dose distribution that could be reproduced in any radiotherapy center with good precision. The method is based on considering total body irradiation as a large and irregular field with heterogeneities. To calculate doses, or doses rates, of each area of interest (head, thorax, thigh, etc.), scattered radiation is determined. It was observed that if dismagnified fields were considered to calculate the scattered radiation, the resulting values could be applied on a projection to the real size to obtain the values for dose rate calculations. In a parallel work it was determined the variation of the dose rate in the air, for the distance of treatment, and for points out of the central axis. This confirm that the use of the inverse square law is not valid. An attenuation curve for a broad beam was also determined in order to allow the use of absorbers. In this work all the adapted formulas for dose rate calculations in several areas of the body are described, as well time/dose templates sheets for total body irradiation. The in vivo dosimetry, proved that either experimental or calculated dose rate values (achieved by the proposed method), did not have significant discrepancies. (author)

  20. Bioimpedance index for measurement of total body water in severely malnourished children

    DEFF Research Database (Denmark)

    Girma, Tsinuel; Kæstel, Pernille; Workeneh, Netsanet

    2016-01-01

    BACKGROUND & OBJECTIVES: Restoration of body composition indicates successful management of severe acute malnutrition (SAM). Bioimpedance (BI) index (height(2)/resistance) is used to predict total body water (TBW) but its performance in SAM, especially with oedema, requires further investigation....... SUBJECTS/METHODS: Children with SAM (mid-arm circumference ...Hzs. Pre- and post-deuterium dose saliva samples were analysed using isotope-ratio mass spectrometry. TBW was regressed on H(2)/Z. Xc and R were height (H)-indexed, and Xc/H plotted against R/H. RESULTS: Thirty five children (16 non-oedematous and 19 oedematous) with median (interquartile range) age of 42...

  1. Measurement of total-body cobalt-57 vitamin B12 absorption with a gamma camera

    International Nuclear Information System (INIS)

    Cardarelli, J.A.; Slingerland, D.W.; Burrows, B.A.; Miller, A.

    1985-01-01

    Previously described techniques for the measurement of the absorption of [ 57 Co]vitamin B 12 by total-body counting have required an iron room equipped with scanning or multiple detectors. The present study uses simplifying modifications which make the technique more available and include the use of static geometry, the measurement of body thickness to correct for attenuation, a simple formula to convert the capsule-in-air count to a 100% absorption count, and finally the use of an adequately shielded gamma camera obviating the need of an iron room

  2. Total body calcium by neutron activation analysis. Reference data for children

    International Nuclear Information System (INIS)

    Ellis, K.J.; Shypailo, R.J.

    2001-01-01

    There is a paucity of data on the chemical composition of the human body during growth. Total body calcium (TBCa) has been reported for only one male child, aged 41/2 yr. TBCa values for 25 children and 27 young women using in vivo neutron activation analysis have been obtained. TBCa results were lower than those reported for the one male cadaver, as well as the estimates derived for the 'Reference Man' model. It was concluded that the reference values for TBCa may need to be adjusted to appropriately describe skeletal mineralization of contemporary children. (author)

  3. The use of Total Body In Vivo Neutron Activation Analysis (TBIVNAA) in balance studies in rodents

    International Nuclear Information System (INIS)

    Smith, D.A.; Lindsay, R.L.; Anderson, J.

    1976-01-01

    In the investigation of animals subject to alteration in diet or other metabolic experiments, the measurements of change in body calcium, phosphorus, sodium and nitrogen are of considerable interest. However, conventional balance studies are tedious and subject to both random and cumulative error, necessitating as they do accurate estimates of dietary intake and faecal and urinary output. The object of the present study was to determine the usefulness of total body in vivo neutron activation analysis, used at the beginning and end of the experimental period, as an alternative to conventional balance techniques. (orig.) [de

  4. Fractionated homogenous total-body irradiation prior to bone marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Duehmke, E; Brix, F; Hebbinghaus, D; Jensen, M; Wendhausen, H; Schmitz, N

    1985-03-01

    At the University of Kiel, myeloid and acute lymphatic leukemia is treated since 1983 by total-body irradiation applied prior to bone marrow transplantation. Dose deviations in the midplane caused by the irregular surface and tissue inhomogeneities of the patient are reduced down to +-3.5% compared to the central ray, with the help of CT-based individual compensators. This method prevents above all an excessive dose to the lungs. The radiobiologic advantages of fractionated irradiation have been employed for all patients treated hitherto (n = 9). At present, a total body dose of 12 Gy in six fractions is applied within three days. There were no undesired acute radiogenic reactions except a mild acute mucositis found in all patients. Chronic side effects, especially in the lungs, were not demonstrated, too. However, the average follow-up time of 149 days has been rather short. One patient died from relapse of leukemia after a total dose of 10 Gy, another patient died because the transplanted bone marrow was rejected, and a third died from catheter sepsis. Six out of nine patients are in complete remission with a maximum index of Karnofsky. The limited experiences gained hitherto show that the homogeneous accelerated-fractionated total-body irradiation offers essential advantages compared to non-compensated single dose irradiation with respect to the prevention of undesired radiogenic effects in sound tissues and that its therapeutic efficacy is at least the same.

  5. Investigation of the Unsteady Total Pressure Profile Corresponding to Counter-Rotating Vortices in an Internal Flow Application

    Science.gov (United States)

    Gordon, Kathryn; Morris, Scott; Jemcov, Aleksandar; Cameron, Joshua

    2013-11-01

    The interaction of components in a compressible, internal flow often results in unsteady interactions between the wakes and moving blades. A prime example in which this flow feature is of interest is the interaction between the downstream rotor blades in a transonic axial compressor with the wake vortices shed from the upstream inlet guide vane (IGV). Previous work shows that a double row of counter-rotating vortices convects downstream into the rotor passage as a result of the rotor blade bow shock impinging on the IGV. The rotor-relative time-mean total pressure distribution has a region of high total pressure corresponding to the pathline of the vortices. The present work focuses on the relationship between the magnitude of the time-mean rotor-relative total pressure profile and the axial spacing between the IGV and the rotor. A survey of different axial gap sizes is performed in a two-dimensional computational study to obtain the sensitivity of the pressure profile amplitude to IGV-rotor axial spacing.

  6. Analytical Model of Doppler Spectra of Light Backscattered from Rotating Convex Bodies of Revolution in the Global Cartesian Coordinate System

    International Nuclear Information System (INIS)

    Yan-Jun, Gong; Zhen-Sen, Wu; Jia-Ji, Wu

    2009-01-01

    We present an analytical model of Doppler spectra in backscattering from arbitrary rough convex bodies of revolution rotating around their axes in the global Cartesian coordinate system. This analytical model is applied to analyse Doppler spectra in backscatter from two cones and two cylinders, as well as two ellipsoids of revolution. We numerically analyse the influences of attitude and geometry size of objects on Doppler spectra. The analytical model can give contribution of the surface roughness, attitude and geometry size of convex bodies of revolution to Doppler spectra and may contribute to laser Doppler velocimetry as well as ladar applications

  7. Stress-reaction during hypokinesia and its effect on total resistance of the animal body

    International Nuclear Information System (INIS)

    Chernov, I.P.

    1980-01-01

    In the experiments on rats, shown has been that three-phase stress-reaction develops during the hypokinetic syndrome formation. This reaction is confirmed by specific changes of general state of the organism, body mass and by the activity of hypothalamic-hypophysial-adrenal system evaluated by oscillations of relative mass of pituitary body and adrenal glands and by karyometry of neuron of the hypothalamus arcuate nuclear and cells of zona fasciculata of adrenal glands. The hypokinetic stress affects the total resistance of the body, its sensitivity to gamma-irradiation in the dose of 800 rad. On the definite stage of development the hypokinetic stress forms the state of heightened ''cross'' stability

  8. Optimum combination of targeted 131I and total body irradiation for treatment of disseminated cancer

    International Nuclear Information System (INIS)

    Amin, Amin E.; Wheldon, Tom E.; O'Donoghue, Joseph A.; Gaze, Mark N.; Barrett, Ann

    1995-01-01

    Purpose: Radiobiological modeling was used to explore optimum combination strategies for treatment of disseminated malignancies of differing radiosensitivity and differing patterns of metastatic spread. The purpose of the study was to derive robust conclusions about the design of combination strategies that incorporate a targeting component. Preliminary clinical experience of a neuroblastoma treatment strategy, which is based upon general principles obtained from modelling, is briefly described. Methods and Materials: The radiobiological analysis was based on an extended (dose-rate dependent) formulation of the linear quadratic model. Radiation dose and dose rate for targeted irradiation of tumors of differing size was in part based on microdosimetric considerations. The analysis was applied to several tumor types with postulated differences in the pattern of metastatic spread, represented by the steepness of the slope of the relationship between numbers of tumors present and tumor diameter. The clinical pilot study entailed the treatment of five children with advanced neuroblastoma using a combination of 131 I metaiodobenzylguanidine (mIBG) and total body irradiation followed by bone marrow rescue. Results: The theoretical analysis shows that both intrinsic radiosensitivity and pattern of metastatic spread can influence the composition of the ideal optimum combination strategy. High intrinsic radiosensitivity generally favors a high proportion of targeting component in the combination treatment, while a strong tendency to micrometastatic spread favors a major contribution by total body irradiation. The neuroblastoma patients were treated using a combination regimen with an initially low targeting component (2 Gy whole body dose from targeting component plus 12 Gy from total body irradiation). The treatment was tolerable and resulted in remissions in excess of 9 months in each of these advanced neuroblastoma patients. Conclusions: Radiobiological analysis, which

  9. Measurement of total body calcium in osteoporotic patients treated with salmon calcitonin

    International Nuclear Information System (INIS)

    Zanzi, I.; Thompson, K.; Cohn, S.H.

    1981-01-01

    In the past, the evaluation of therapies for osteoporosis has been limited by the lack of a suitable quantitative end point. The introduction of the technique of in vivo total body neutron activation analysis (TBNAA) has made possible the precise and accurate measurement of total body calcium (TBCa). Since almost 99 percent of TBCa is in the skeleton, TBNAA gives a direct measurement of skeletal mass. Thus, changes in skeletal mass serve as an objective criterion in the evaluation of the efficacy of the therapy in osteoporosis. Studies performed at Brookhaven National Laboratory and elsewhere have reported the use of calcitonin (CT) in the treatment of primary osteoporosis and related conditions in a limited number of patients. The physiological effects of CT as an inhibitor of bone resorption has been the rationale of its use. The results of a randomized, controlled, 2 year therapeutical trial of CT in a group of postmenopausal osteoporotic women are presented in this report

  10. Total-body photography in skin cancer screening: the clinical utility of standardized imaging.

    Science.gov (United States)

    Rosenberg, Alexandra; Meyerle, Jon H

    2017-05-01

    Early detection of skin cancer is essential to reducing morbidity and mortality from both melanoma and nonmelanoma skin cancers. Total-body skin examinations (TBSEs) may improve early detection of malignant melanomas (MMs) but are controversial due to the poor quality of data available to establish a mortality benefit from skin cancer screening. Total-body photography (TBP) promises to provide a way forward by lowering the costs of dermatologic screening while simultaneously leveraging technology to increase patient access to dermatologic care. Standardized TBP also offers the ability for dermatologists to work synergistically with modern computer technology involving algorithms capable of analyzing high-quality images to flag concerning lesions that may require closer evaluation. On a population level, inexpensive TBP has the potential to increase access to skin cancer screening and it has several specific applications in a military population. The utility of standardized TBP is reviewed in the context of skin cancer screening and teledermatology.

  11. Total Body Capacitance for Estimating Human Basal Metabolic Rate in an Egyptian Population

    Science.gov (United States)

    M. Abdel-Mageed, Samir; I. Mohamed, Ehab

    2016-01-01

    Determining basal metabolic rate (BMR) is important for estimating total energy needs in the human being yet, concerns have been raised regarding the suitability of sex-specific equations based on age and weight for its calculation on an individual or population basis. It has been shown that body cell mass (BCM) is the body compartment responsible for BMR. The objectives of this study were to investigate the relationship between total body capacitance (TBC), which is considered as an expression for BCM, and BMR and to develop a formula for calculating BMR in comparison with widely used equations. Fifty healthy nonsmoking male volunteers [mean age (± SD): 24.93 ± 4.15 year and body mass index (BMI): 25.63 ± 3.59 kg/m2] and an equal number of healthy nonsmoking females matched for age and BMI were recruited for the study. TBC and BMR were measured for all participants using octopolar bioelectric impedance analysis and indirect calorimetry techniques, respectively. A significant regressing equation based on the covariates: sex, weight, and TBC for estimating BMR was derived (R=0.96, SEE=48.59 kcal, and P<0.0001), which will be useful for nutritional and health status assessment for both individuals and populations. PMID:27127453

  12. THE URINE PROTEOME FOR RADIATION BIODOSIMETRY: EFFECT OF TOTAL BODY VERSUS LOCAL KIDNEY IRRADIATION

    Science.gov (United States)

    Sharma, Mukut; Halligan, Brian D.; Wakim, Bassam T.; Savin, Virginia J.; Cohen, Eric P.; Moulder, John E.

    2009-01-01

    Victims of nuclear accidents or radiological terrorism are likely to receive varying doses of ionizing radiation inhomogeneously distributed over the body. Early biomarkers may be useful in determining organ-specific doses due to total body irradiation (TBI) or partial body irradiation. We used liquid chromatography and mass spectrometry to compare the effect of TBI and local kidney irradiation (LKI) on the rat urine proteome using a single 10 Gy dose of X-rays. Both TBI and LKI altered the urinary protein profile within 24 hours with noticeable differences in Gene Ontology categories. Some proteins including fetuin-B, tissue kallikrein, beta-glucuronidase, vitamin D-dependent calcium binding protein and chondroitin sulfate proteoglycan NG2 were detected only in the TBI group. Some other proteins including major urinary protein-1, RNA binding protein 19, neuron navigator, Dapper homolog 3, WD repeat and FYVE domain containing protein 3, sorting nexin-8, ankycorbin and aquaporin were detected only in the LKI group. Protease inhibitors and kidney proteins were more abundant (fraction of total scans) in the LKI group. Up/Uc ratio and urinary albumin abundance decreased in both TBI and LKI groups. Several markers of acute kidney injury were not detectable in either irradiated group. Present data indicate that abundance and number of proteins may follow opposite trends. These novel findings demonstrate intriguing differences between TBI and LKI, and suggest that urine proteome may be useful in determining organ-specific changes caused by partial body irradiation. PMID:20065682

  13. The urine proteome for radiation biodosimetry: effect of total body vs. local kidney irradiation.

    Science.gov (United States)

    Sharma, Mukut; Halligan, Brian D; Wakim, Bassam T; Savin, Virginia J; Cohen, Eric P; Moulder, John E

    2010-02-01

    Victims of nuclear accidents or radiological terrorism are likely to receive varying doses of ionizing radiation inhomogeneously distributed over the body. Early biomarkers may be useful in determining organ-specific doses due to total body irradiation (TBI) or partial body irradiation. The authors used liquid chromatography and mass spectrometry to compare the effect of TBI and local kidney irradiation (LKI) on the rat urine proteome using a single 10-Gy dose of x-rays. Both TBI and LKI altered the urinary protein profile within 24 h with noticeable differences in gene ontology categories. Some proteins, including fetuin-B, tissue kallikrein, beta-glucuronidase, vitamin D-dependent calcium binding protein and chondroitin sulfate proteoglycan NG2, were detected only in the TBI group. Some other proteins, including major urinary protein-1, RNA binding protein 19, neuron navigator, Dapper homolog 3, WD repeat and FYVE domain containing protein 3, sorting nexin-8, ankycorbin and aquaporin were detected only in the LKI group. Protease inhibitors and kidney proteins were more abundant (fraction of total scans) in the LKI group. Urine protein (Up) and creatinine (Uc) (Up/Uc) ratios and urinary albumin abundance decreased in both TBI and LKI groups. Several markers of acute kidney injury were not detectable in either irradiated group. Present data indicate that abundance and number of proteins may follow opposite trends. These novel findings demonstrate intriguing differences between TBI and LKI, and suggest that urine proteome may be useful in determining organ-specific changes caused by partial body irradiation.

  14. Total body-calcium measurements: comparison of two delayed-gamma neutron activation facilities

    International Nuclear Information System (INIS)

    Ma, R.; Ellis, K.J.; Shypailo, R.J.; Pierson, R.N. Jr.

    1999-01-01

    This study compares two independently calibrated delayed-gamma neutron activation (DGNA) facilities, one at the Brookhaven National Laboratory (BNL), Upton, New York, and the other at the Children's Nutrition Research Center (CNRC), Houston, Texas that measure total body calcium (TBCa). A set of BNL phantoms was sent to CNRC for neutron activation analysis, and a set of CNRC phantoms was measured at BNL. Both facilities showed high precision (<2%), and the results were in good agreement, within 5%. (author)

  15. Effect of dietary protein quality on the resistance of rats to total body radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bounous, G.; Pageau, R.

    1983-02-01

    Young rats have been fed four defined-formula diets before and after ..gamma..-irradiation (700 rd (7.0 Gy), 75 rd/min (750 mGy), 80 cm from the source, total body). Animals eating a diet containing lactalbumin hydrolyzate (20 g/100 g diet) exhibited less anorexia and weight loss following ..gamma..-rays than a corresponding group eating casein hydrolyzate (20 g/100 g diet).

  16. Radiological protection in a patient during a total body irradiation procedure

    International Nuclear Information System (INIS)

    Hernandez O, J. O.; Hinojosa G, J.; Gomez M, E.; Balam de la Vega, J. A.; Deheza V, J. C.

    2010-09-01

    A technique used in the Service of Radiotherapy of the Cancer Center of the American British Cowdray Medical Center (ABC) for the bone marrow transplantation, is the total body irradiation. It is known that the dose calculation, for this irradiation type, is old, since the dosimetric calculation is carried out by hand and they exist infinity of techniques for the patients irradiation and different forms of protecting organs of risk, as well as a great uncertainty in the given dose. In the Cancer Center of the ABC Medical Center, was carried out an irradiation procedure to total body with the following methodology: Computerized tomography of the patient total body (two vacuum mattresses in the following positions: dorsal and lateral decubitus), where is combined the two treatment techniques anterior-posterior and bilateral, skin delineate and reference volumes, dose calculation with the planning system Xi O of CMS, dose determination using an ionization chamber and a lung phantom IMRT Thorax Phantom of the mark CIRS and dosimetry in vivo. In this work is presented the used treatment technique, the results, statistics and the actualization of the patient clinical state. (Author)

  17. Late effects on gonadal function of cyclophosphamide, total-body irradiation, and marrow transplantation

    International Nuclear Information System (INIS)

    Sanders, J.E.; Buckner, C.D.; Leonard, J.M.; Sullivan, K.M.; Witherspoon, R.P.; Deeg, H.J.; Storb, R.; Thomas, E.D.

    1983-01-01

    One hundred thirty-seven patients had gonadal function evaluated 1-11 years after marrow transplantation. All 15 women less than age 26 and three of nine older than age 26 who were treated with 200 mg/kg cyclophosphamide recovered normal gonadotropin levels and menstruation. Five have had five pregnancies resulting in three live births, one spontaneous abortion, and one elective abortion. Three of 38 women who were prepared with 120 mg/kg cyclophosphamide and 920-1200 rad total-body irradiation had normal gonadotropin levels and menstruation. Two had pregnancies resulting in one spontaneous and one elective abortion. Of 31 men prepared with 200 mg/kg cyclophosphamide, 30 had normal luteinizing hormone levels, 20 had normal follicle-stimulating hormone levels, and 10 of 15 had spermatogenesis. Four have fathered five normal children. Thirty-six of 41 men prepared with 120 mg/kg cyclophosphamide and 920-1750 rad total-body irradiation had normal luteinizing hormone levels, ten had normal follicle-stimulating hormone levels, and 2 of 32 studied had spermatogenesis. One has fathered two normal children. It was concluded that cyclophosphamide does not prevent return of normal gonadal function in younger women and in most men. Total-body irradiation prevents return of normal gonadal function in the majority of patients

  18. A normal mode treatment of semi-diurnal body tides on an aspherical, rotating and anelastic Earth

    Science.gov (United States)

    Lau, Harriet C. P.; Yang, Hsin-Ying; Tromp, Jeroen; Mitrovica, Jerry X.; Latychev, Konstantin; Al-Attar, David

    2015-08-01

    Normal mode treatments of the Earth's body tide response were developed in the 1980s to account for the effects of Earth rotation, ellipticity, anelasticity and resonant excitation within the diurnal band. Recent space-geodetic measurements of the Earth's crustal displacement in response to luni-solar tidal forcings have revealed geographical variations that are indicative of aspherical deep mantle structure, thus providing a novel data set for constraining deep mantle elastic and density structure. In light of this, we make use of advances in seismic free oscillation literature to develop a new, generalized normal mode theory for the tidal response within the semi-diurnal and long-period tidal band. Our theory involves a perturbation method that permits an efficient calculation of the impact of aspherical structure on the tidal response. In addition, we introduce a normal mode treatment of anelasticity that is distinct from both earlier work in body tides and the approach adopted in free oscillation seismology. We present several simple numerical applications of the new theory. First, we compute the tidal response of a spherically symmetric, non-rotating, elastic and isotropic Earth model and demonstrate that our predictions match those based on standard Love number theory. Second, we compute perturbations to this response associated with mantle anelasticity and demonstrate that the usual set of seismic modes adopted for this purpose must be augmented by a family of relaxation modes to accurately capture the full effect of anelasticity on the body tide response. Finally, we explore aspherical effects including rotation and we benchmark results from several illustrative case studies of aspherical Earth structure against independent finite-volume numerical calculations of the semi-diurnal body tide response. These tests confirm the accuracy of the normal mode methodology to at least the level of numerical error in the finite-volume predictions. They also demonstrate

  19. Total Skin Electron Therapy for Cutaneous T-Cell Lymphoma Using a Modern Dual-Field Rotational Technique

    Energy Technology Data Exchange (ETDEWEB)

    Heumann, Thatcher R. [Emory University School of Medicine, Emory University, Atlanta, Georgia (United States); Esiashvili, Natia [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute (WCI), Emory University, Atlanta, Georgia (United States); Parker, Sareeta [Department of Dermatology, Emory University, Atlanta, Georgia (United States); Switchenko, Jeffrey M. [Biostatistics Shared Core Resource at WCI, Emory University, Atlanta, Georgia (United States); Dhabbaan, Anees [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute (WCI), Emory University, Atlanta, Georgia (United States); Goodman, Michael [Department of Epidemiology, Rollins School of Public Health, Emory University, Atlanta, Georgia (United States); Lechowicz, Mary Jo; Flowers, Christopher R. [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Department of Hematology and Oncology, Emory University, Atlanta, Georgia (United States); Khan, Mohammad K., E-mail: drkhurram2000@gmail.com [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute (WCI), Emory University, Atlanta, Georgia (United States)

    2015-05-01

    Purpose: To report our experience with rotational total skin electron irradiation (RTSEI) in cutaneous T-cell lymphoma (CTCL), and to examine response by disease stage and race. Methods and Materials: We reviewed our outcomes for 68 CTCL patients who received RTSEI (≥30 Gy) from 2000 to 2013. Primary outcomes were complete clinical response (CCR), recurrence-free survival (RFS), and overall survival (OS). Using log–rank tests and Cox proportional hazards, OS and RFS were compared across tumor stages at time of RTSEI with further racial subgroup analysis. Results: Median age at diagnosis and at time of radiation was 52 and 56 years, respectively. Median follow-up was 5.1 years, 49% were African American, and 49% were female. At time of treatment, 18, 37, and 13 patients were T stage 2, 3, and 4, respectively. At 6 weeks after RTSEI, overall CCR was 82% (88%, 83%, and 69% for T2, T3, and T4, respectively). Median RFS was 11 months for all patients and 14, 10, and 12 months for stage T2, T3, and T4, respectively. Tumor stage was not associated with RFS or CCR. Maintenance therapy after RTSEI was associated with improved RFS in both crude and multivariable analysis, controlling for T stage. Median OS was 76 months (91 and 59 months for T3 and T4, respectively). With the exception of improved OS in African Americans compared with whites at stage T2, race was not associated with CCR, RFS, or OS. Conclusions: These results represent the largest RTSEI clinical outcomes study in the modern era using a dual-field rotational technique. Our observed response rates match or improve upon the standard set by previous outcome studies using conventional TSEI techniques, despite a large percentage of advanced CTCL lesions in our cohort. We found that clinical response after RTSEI did not seem to be affected by T stage or race.

  20. Observations on total-body calcium in humans with bone disease

    International Nuclear Information System (INIS)

    Spinks, T.J.; Bewley, D.K.; Ranicar, A.S.O.; Joplin, G.F.; Evans, I.M.A.; Vlotides, J.; Paolillo, M.

    1979-01-01

    Total-body calcium was measured in-vivo by neutron activation in a number of patients suffering from metabolic abnormalities which affect the skeleton. In general, less than 2% of total calcium resides in tissue other than bone allowing calcium mass to be directly related to skeletal mass. The conditions studied were (i) Paget's disease, treated with synthetic human calcitonin, (ii) osteoporosis, treated variously with calcium and phosphate supplements and 1,25 hydroxycholecalciferol, and (iii) Cushing's disease treated by pituitary implant of 198 Au or 90 Y seeds. The neutron beam used in these studies was produced by bombarding a beryllium target with deuterons accelerated in a cyclotron. The mean neutron energy was 7.5 MeV and patients received a total dose of 1 rem in about 30 s, a bilateral irradiation being employed. Measurements were made at approximately yearly intervals, the maximum period of study being about four and a half years. The precision of the method was estimated to be +-3% (SE) and a correction was applied for changes in body weight. In most patients, total calcium remained stable. However, in the Paget's patients, there was an indication of a slow upward trend while the osteoporotics (both treated and untreated) showed on average no change. Most of the patients with Cushing's disease showed no recovery of skeletal mass. Absolute calibration indicated that mean total body calcium in the Paget's patients was close to a predicted normal while that for the osteoporotic and Cushing's patients was 20-25% below this. (author)

  1. A fluid Foucault pendulum: the impossibility of achieving solid-body rotation on Earth

    Science.gov (United States)

    Blum, Robert; Zimmerman, Daniel; Triana, Santiago; Lathrop, Daniel

    2012-11-01

    Rotating fluid dynamics is key to our understanding of the Earth's atmosphere, oceans, and core, along with a plethora of astrophysical objects. Laboratory study of these natural systems often involves spinning experimental devices, which are assumed to tend to rigid rotation when unstirred. We present results showing that even at the tabletop scale, there is a measurable oscillatory flow driven by the precession of the experiment's axis as the earth rotates. We measure this flow in a rotating cylinder with an adjustable aspect ratio. The horizontal flow in the rotating frame is measured using particle tracking. The steady state is well-described by an inertial mode whose amplitude is maximum when the height to diameter ratio is 0.995, which matches theoretical predictions. We also quantify the resonant amplitude of the inertial mode in the cylinder and estimate the amplitude in other devices. We compare our results to similar studies done in spherical devices. [Triana et al., JGR, 117 (2012), B04103][Boisson et al., EPL, 98 (2012), 59002].

  2. SU-E-T-357: Electronic Compensation Technique to Deliver Total Body Dose

    Energy Technology Data Exchange (ETDEWEB)

    Lakeman, T [State University of New York at Buffalo, Buffalo, NY (United States); Wang, I; Podgorsak, M [State University of New York at Buffalo, Buffalo, NY (United States); Roswell Park Cancer Institute, Buffalo, NY (United States)

    2015-06-15

    Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient’s immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has conventionally been used to compensate for the varying thickness through the entire body in large-field TBI. The goal of this study is to pursue utilizing the modern electronic compensation technique to more accurately and efficiently deliver dose to patients in need of TBI. Methods: Treatment plans utilizing electronic compensation to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Each treatment plan includes two, specifically weighted, pair of opposed fields. One pair of open, large fields (collimator=45°), to encompass the patient’s entire anatomy, and one pair of smaller fields (collimator=0°) focused only on the thicker midsection of the patient. The optimal fluence for each one of the smaller fields was calculated at a patient specific penetration depth. Irregular surface compensators provide a more uniform dose distribution within the smaller opposed fields. Results: Dose-volume histograms (DVH) were calculated for the evaluating the electronic compensation technique. In one case, the maximum body doses calculated from the DVH were reduced from the non-compensated 195.8% to 165.3% in the electronically compensated plans, indicating a more uniform dose with the region of electronic compensation. The mean body doses calculated from the DVH were also reduced from the non-compensated 120.6% to 112.7% in the electronically compensated plans, indicating a more accurate delivery of the prescription dose. All calculated monitor units were well within clinically acceptable limits. Conclusion: Electronic compensation technique for TBI will not substantially increase the beam on time while it can significantly reduce the compensator

  3. The effect of tranexamic acid on blood coagulation in total hip replacement arthroplasty: rotational thromboelastographic (ROTEM®) analysis.

    Science.gov (United States)

    Na, H S; Shin, H J; Lee, Y J; Kim, J H; Koo, K H; Do, S H

    2016-01-01

    We evaluated changes in rotational thromboelastometry (ROTEM(®) ) parameters and clinical outcomes in patients undergoing total hip replacement arthroplasty, with concomitant infusions of tranexamic acid and of 6% hydroxyethyl starch 130/0.4. Fifty-five patients were randomly assigned to either the tranexamic acid (n = 29) or the control (n = 26) group. Hydroxyethyl starch was administered in the range of 10-15 ml.kg(-1) during the operation in both groups. In the control group, the clot formation time and maximum clot firmness of APTEM showed significant differences when compared with those of EXTEM at one hour postoperatively, suggestive of fibrinolysis. In the tranexamic acid group, there was no significant difference between each postoperative EXTEM and APTEM parameter. In the tranexamic acid and control group, postoperative blood loss was 308 ml (210-420 [106-745]) and 488 ml (375-620 [170-910], p = 0.002), respectively, and total blood loss was 1168 ml (922-1470 [663-2107]) and 1563 ml (1276-1708 [887-1494], p = 0.003). Haemoglobin concentration was higher in the tranexamic acid group on the second postoperative day (10.5 (9.4-12.1 [7.9-14.0]) vs. 9.6 (8.9-10.5[7.3-16.0]) g.dl(-1) , p = 0.027). In patients undergoing total hip replacement arthroplasty, postoperative fibrinolysis aggravated by hydroxyethyl starch was attenuated by co-administration of 10 mg.kg(-1) tranexamic acid, which may have led to less postoperative blood loss. © 2015 The Association of Anaesthetists of Great Britain and Ireland.

  4. Total proteins and protein fractions levels in pregnant rats subjected to whole-body gamma irradiation

    International Nuclear Information System (INIS)

    Mansour, M.A.; Roushdy, H.M.; Mazhar, F.M.; Abu-Gabal, H.A.

    1986-01-01

    A total number of 180 mature rats (120 females and 60 males) weighing from 120-140 g were used to study the effect of two doses (2 and 4 Gy) whole-body gamma irradiation on the level of total protein and protein fractions in serum of pregnant rats during the period of organogenesis. It was found that the levels of total protein, albumin and gamma globulins significantly decreased according to the doses of exposure. The levels of alpha and beta globulins significantly increased more in the serum of rats exposed to 2 Gy than in rats exposed to 4 Gy. The level of A/G ratio significantly decreased more in the serum of rats exposed to 2Gy than in those exposed to 4 Gy

  5. Rigid-body rotation of an electron cloud in divergent magnetic fields

    International Nuclear Information System (INIS)

    Fruchtman, A.; Gueroult, R.; Fisch, N. J.

    2013-01-01

    For a given voltage across a divergent poloidal magnetic field, two electric potential distributions, each supported by a rigid-rotor electron cloud rotating with a different frequency, are found analytically. The two rotation frequencies correspond to the slow and fast rotation frequencies known in uniform plasma. Due to the centrifugal force, the equipotential surfaces, that correspond to the two electric potential distributions, diverge more than the magnetic surfaces do, the equipotential surfaces in the fast mode diverge largely in particular. The departure of the equipotential surfaces from the magnetic field surfaces may have a significant focusing effect on the ions accelerated by the electric field. The focusing effect could be important for laboratory plasma accelerators as well as for collimation of astrophysical jets

  6. Creatine Supplementation Increases Total Body Water in Soccer Players: a Deuterium Oxide Dilution Study.

    Science.gov (United States)

    Deminice, R; Rosa, F T; Pfrimer, K; Ferrioli, E; Jordao, A A; Freitas, E

    2016-02-01

    This study aimed to evaluate changes in total body water (TBW) in soccer athletes using a deuterium oxide dilution method and bioelectrical impedance (BIA) formulas after 7 days of creatine supplementation. In a double-blind controlled manner, 13 healthy (under-20) soccer players were divided randomly in 2 supplementation groups: Placebo (Pla, n=6) and creatine supplementation (CR, n=7). Before and after the supplementation period (0.3 g/kg/d during 7 days), TBW was determined by deuterium oxide dilution and BIA methods. 7 days of creatine supplementation lead to a large increase in TBW (2.3±1.0 L) determined by deuterium oxide dilution, and a small but significant increase in total body weight (1.0±0.4 kg) in Cr group compared to Pla. The Pla group did not experience any significant changes in TBW or body weight. Although 5 of 6 BIA equations were sensitive to determine TBW changes induced by creatine supplementation, the Kushner et al. 16 method presented the best concordance levels when compared to deuterium dilution method. In conclusion, 7-days of creatine supplementation increased TBW determined by deuterium oxide dilution or BIA formulas. BIA can be useful to determine TBW changes promoted by creatine supplementation in soccer athletes, with special concern for formula choice. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Does the athletes? body shape the athletes? mind? A few ideas on athletes? mental rotation performance. Commentary on Jansen and Lehmann

    OpenAIRE

    Heinen, Thomas

    2013-01-01

    Athletes exhibit differences in perceptual-cognitive abilities when compared to non-athletes. Recent theoretical developments focus on the role of the athletes? body in perceptual-cognitive tasks such as mental rotation tasks. It is assumed that the degree to which stimuli in mental rotation tasks can be embodied facilitates the mental rotation process. The implications of this assumption are discussed and ideas for future research are presented.

  8. The dosimetry of cobalt-60 γ-ray total body irradiation before bone marrow transplantation

    International Nuclear Information System (INIS)

    Dong Fan; Zhang Guiru

    1989-11-01

    The dosimetric considerations of using conventional cobalt-60 unit total body irradiation (TBI) are presented. By extending the source-to-midplane distance (SMD) to 346 cm, a 92 x 98 cm 2 rectangular field with diagonal dimension 134 cm was obtained. The results from the phantom measurements showed: (1) the effective field corresponding to an average-size patient is 25 x 25 cm 2 , and a method for estimating the effective field of human body is given; (2) the midplane doses are consistently higher than those of surfaces, but the dose ratio of midplane to surface decreases as the body thickness increases, and a significant negative correlation is existed between the dose ratio and thickness, thus a linear regression line is fitted; (3) the anterior-posterior (AP) or AP + bilateral irradiation will yield a more uniform dose distribution in the whole body than the bilateral irradiation; (4) the dose uniformity can apparently be improved by the tissue compensation, for which the technique is described

  9. Quantitative image reconstruction for total-body PET imaging using the 2-meter long EXPLORER scanner

    Science.gov (United States)

    Zhang, Xuezhu; Zhou, Jian; Cherry, Simon R.; Badawi, Ramsey D.; Qi, Jinyi

    2017-03-01

    The EXPLORER project aims to build a 2 meter long total-body PET scanner, which will provide extremely high sensitivity for imaging the entire human body. It will possess a range of capabilities currently unavailable to state-of-the-art clinical PET scanners with a limited axial field-of-view. The huge number of lines-of-response (LORs) of the EXPLORER poses a challenge to the data handling and image reconstruction. The objective of this study is to develop a quantitative image reconstruction method for the EXPLORER and compare its performance with current whole-body scanners. Fully 3D image reconstruction was performed using time-of-flight list-mode data with parallel computation. To recover the resolution loss caused by the parallax error between crystal pairs at a large axial ring difference or transaxial radial offset, we applied an image domain resolution model estimated from point source data. To evaluate the image quality, we conducted computer simulations using the SimSET Monte-Carlo toolkit and XCAT 2.0 anthropomorphic phantom to mimic a 20 min whole-body PET scan with an injection of 25 MBq 18F-FDG. We compare the performance of the EXPLORER with a current clinical scanner that has an axial FOV of 22 cm. The comparison results demonstrated superior image quality from the EXPLORER with a 6.9-fold reduction in noise standard deviation comparing with multi-bed imaging using the clinical scanner.

  10. Total body irradiation: what schedule(s). Les irradiations corporelles totales: quel(s) schema(s)

    Energy Technology Data Exchange (ETDEWEB)

    Cosset, J M [Institut Curie, 75 - Paris (France)

    1993-01-01

    In this article, the author explains why a whole-body irradiation is still an essential step before a bone marrow graft. He presents irradiation protocols for acute myeloid leukemia and chronic myeloid leukemia. 14 refs.

  11. Comparison of total body irradiation-based or non-total body irradiation-based conditioning regimens for allogeneic stem cell transplantation in pediatric leukemia patients

    Directory of Open Access Journals (Sweden)

    Sang Jeong Kim

    2010-04-01

    Full Text Available Purpose : This study aims to compare the outcome of total body irradiation (TBI- or non-TBI-containing conditioning regimens for leukemia in children. Methods : We retrospectively evaluated 77 children conditioned with TBI (n=40 or non-TBI (n=37 regimens, transplanted at Chonnam National University Hospital between January 1996 and December 2007. The type of transplantation, disease status at the time of transplant, conditioning regimen, engraftment kinetics, development of graft-versus-host disease (GVHD, complications, cause of deaths, overall survival (OS, and event-free survival (EFS were compared between the 2 groups. Results : Among 34 patients with acute lymphoblastic leukemia (ALL, 28 (82.4% were in the TBI group, while 72.7% (24/33 of patients with myeloid leukemia were in the non-TBI group. Although the 5-year EFS of the 2 groups was similar for all patients (62% vs 63%, the TBI group showed a better 5-year EFS than the non-TBI group when only ALL patients were analyzed (65% vs 17%; P =0.005. In acute myelogenous leukemia patients, the non-TBI group had better survival tendency (73% vs 38%; P=0.089. The incidence of GVHD, engraftment, survival, cause of death, and late complications was not different between the 2 groups. Conclusion : The TBI and non-TBI groups showed comparable results, but the TBI group showed a significantly higher 5-year EFS than the non-TBI group in ALL patients. Further prospective, randomized controlled studies involving larger number of patients are needed to assess the late-onset complications and to compare the socioeconomic quality of life.

  12. Fetal liver transplantation in 2 patients with acute leukaemia after total body irradiation

    International Nuclear Information System (INIS)

    Lucarelli, G.; Izzi, T.; Porcellini, A.; Delfini, C.; Galimberti, M.; Moretti, L.; Polchi, P.; Agostinelli, F.; Andreani, M.; Manna, M.; Dallapiccola, B.

    1982-01-01

    2 patients with acute leukaemia in relapse were transplanted with fetal liver cells following a conditioning regimen of cyclophosphamide (120 mg/kg) and total body irradiation (1000 r). Each patient achieved a remission with haematopoietic recovery that was rapid in one case and delayed in the other. In one case there was evidence of chimerism as demonstrated by the presence of the XYY karyotype of the donor fetus in 20 % of marrow metaphases, by the presence of double Y bodies in the peripheral blood, by the appearance of new HLA-antigens, and by red cell isoenzyme phenotypes of donor origin. In the second case there was prompt haemotopoietic recovery and the appearance of red cell isoenzyme phenotypes of donor origin. Survival was 153 and 30 d, respectively, and both patients died of interstitial pneumonia without evidence of graft versus host disease. (author)

  13. Serum immunoglobulin levels in humans exposed to therapeutic total-body gamma irradiation

    International Nuclear Information System (INIS)

    Chaskes, S.; Kingdon, G.C.; Balish, E.

    1975-01-01

    Reduced serum immunoglobulin (IgA, IgG, IgM) levels developed in the majority of 27 patients with hematologic disorders after treatment with 100 to 350 R total-body gamma-ray exposures at a dose rate of either 1.5 R/min to 1.5 R/hr. A reduction in IgA of 20 percent or more was found in 66 percent of the cases, while 56 percent showed an IgM decrease, and 49 percent an IgG decrease of 20 percent. The severity of immunoglobulin depression was influenced by the total radiation dose and the patient's primary disease. The occurrence of IgG and IgM depression was greater when the radiation was given at 1.5 R/hr than when the dose rate was 1.5 R/min. Substantial but incomplete recovery toward preirradiation immunoglobulin levels was found for most patients by 7 wk after total-body irradiation (TBI). (U.S.)

  14. Reliability of the Phi angle to assess rotational alignment of the talar component in total ankle replacement.

    Science.gov (United States)

    Manzi, Luigi; Villafañe, Jorge Hugo; Indino, Cristian; Tamini, Jacopo; Berjano, Pedro; Usuelli, Federico Giuseppe

    2017-11-08

    The purpose of this study was to investigate the test-retest reliability of the Phi angle in patients undergoing total ankle replacement (TAR) for end stage ankle osteoarthritis (OA) to assess the rotational alignment of the talar component. Retrospective observational cross-sectional study of prospectively collected data. Post-operative anteroposterior radiographs of the foot of 170 patients who underwent TAR for the ankle OA were evaluated. Three physicians measured Phi on the 170 randomly sorted and anonymized radiographs on two occasions, one week apart (test and retest conditions), inter and intra-observer agreement were evaluated. Test-retest reliability of Phi angle measurement was excellent for patients with Hintegra TAR (ICC=0.995; pPhi angle measurement between patients with Hintegra vs. Zimmer implants (p>0.05). Measurement of Phi angle on weight-bearing dorsoplantar radiograph showed an excellent reliability among orthopaedic surgeons in determining the position of the talar component in the axial plane. Level II, cross sectional study. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  15. Extrinsic Factors as Component Positions to Bone and Intrinsic Factors Affecting Postoperative Rotational Limb Alignment in Total Knee Arthroplasty.

    Science.gov (United States)

    Mochizuki, Tomoharu; Sato, Takashi; Tanifuji, Osamu; Watanabe, Satoshi; Kobayashi, Koichi; Endo, Naoto

    2018-02-13

    This study aimed to identify the factors affecting postoperative rotational limb alignment of the tibia relative to the femur. We hypothesized that not only component positions but also several intrinsic factors were associated with postoperative rotational limb alignment. This study included 99 knees (90 women and 9 men) with a mean age of 77 ± 6 years. A three-dimensional (3D) assessment system was applied under weight-bearing conditions to biplanar long-leg radiographs using 3D-to-2D image registration technique. The evaluation parameters were (1) component position; (2) preoperative and postoperative coronal, sagittal, and rotational limb alignment; (3) preoperative bony deformity, including femoral torsion, condylar twist angle, and tibial torsion; and (4) preoperative and postoperative range of motion (ROM). In multiple linear regression analysis using a stepwise procedure, postoperative rotational limb alignment was associated with the following: (1) rotation of the component position (tibia: β = 0.371, P intrinsic factors, such as preoperative rotational limb alignment, ROM, and tibial torsion, affected postoperative rotational limb alignment. On a premise of correct component positions, the intrinsic factors that can be controlled by surgeons should be taken care. In particular, ROM is necessary to be improved within the possible range to acquire better postoperative rotational limb alignment. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Renal toxicity in children undergoing total body irradiation for bone marrow transplant

    International Nuclear Information System (INIS)

    Esiashvili, Natia; Chiang, K.-Y.; Hasselle, Michael D.; Bryant, Cynthia; Riffenburgh, Robert H.; Paulino, Arnold C.

    2009-01-01

    Purpose: Contribution of total body irradiation (TBI) to renal toxicity in children undergoing the bone marrow transplant (BMT) remains controversial. We report our institutional retrospective study that evaluates the frequency of acute and chronic renal dysfunction in children after using total body irradiation (TBI) conditioning regimens. Materials and methods: Between 1995 and 2003, 60 children with hematological malignancies underwent TBI as part of a conditioning regimen before allogeneic BMT. Patients received 4-14 Gy at 1.75-2 Gy/fraction in six-eight fractions. Lung shielding was used in all patients to limit lung dose to less than 10 Gy; renal shielding was not utilized. All patients had baseline renal function assessment and renal dysfunction post-BM was mainly evaluated on the basis of persistent serum creatinine elevation at acute (0-90 days) and chronic (>90 days) intervals after completion of BMT. Results: Acute renal dysfunction (ARD) was documented in 27 patients (45%); the majority had concurrent diagnosis of veno-occlusive disease (VOD) or graft-versus-host disease (GVHD) and other potential causes (sepsis, antibiotic). The risk for delayed renal dysfunction (DRD) at 1 year approached 25% for surviving patients. The ARD was strongly linked with the risk of the DRD. There was no statistically significant relationship between ARD, DRD and underlying diagnosis, GVHD, VOD or TBI doses with both univariate and multivariate analyses. The younger age (<5 years) had significantly increased risk for the development of ARD (p = 0.011). Conclusion: Our analysis validates high incidence of renal dysfunction in the pediatric BMT population. In contrast to other reports we did not find total body irradiation dose to be a risk factor for renal dysfunction. Future prospective studies are needed to assess risk factors and interventions for this serious toxicity in children following allogeneic BM

  17. High dietary protein intake is associated with an increased body weight and total death risk.

    Science.gov (United States)

    Hernández-Alonso, Pablo; Salas-Salvadó, Jordi; Ruiz-Canela, Miguel; Corella, Dolores; Estruch, Ramón; Fitó, Montserrat; Arós, Fernando; Gómez-Gracia, Enrique; Fiol, Miquel; Lapetra, José; Basora, Josep; Serra-Majem, Lluis; Muñoz, Miguel Ángel; Buil-Cosiales, Pilar; Saiz, Carmen; Bulló, Mònica

    2016-04-01

    High dietary protein diets are widely used to manage overweight and obesity. However, there is a lack of consensus about their long-term efficacy and safety. Therefore, the aim of this study was to assess the effect of long-term high-protein consumption on body weight changes and death outcomes in subjects at high cardiovascular risk. A secondary analysis of the PREDIMED trial was conducted. Dietary protein was assessed using a food-frequency questionnaire during the follow-up. Cox proportional hazard models were used to estimate the multivariate-adjusted hazard ratio (HR) and 95% confidence intervals (95%CI) for protein intake in relation to the risk of body weight and waist circumference changes, cardiovascular disease, cardiovascular death, cancer death and total death. Higher total protein intake, expressed as percentage of energy, was significantly associated with a greater risk of weight gain when protein replaced carbohydrates (HR: 1.90; 95%CI: 1.05, 3.46) but not when replaced fat (HR: 1.69; 95%CI: 0.94, 3.03). However, no association was found between protein intake and waist circumference. Contrary, higher total protein intake was associated with a greater risk of all-cause death in both carbohydrate and fat substitution models (HR: 1.59; 95%CI: 1.08, 2.35; and HR: 1.66; 95%CI: 1.13, 2.43, respectively). A higher consumption of animal protein was associated with an increased risk of fatal and non-fatal outcomes when protein substituted carbohydrates or fat. Higher dietary protein intake is associated with long-term increased risk of body weight gain and overall death in a Mediterranean population at high cardiovascular risk. Copyright © 2015 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  18. Dizzy people perform no worse at a motor imagery task requiring whole body mental rotation; a case-control comparison

    Directory of Open Access Journals (Sweden)

    Sarah B Wallwork

    2013-06-01

    Full Text Available We wanted to find out whether people who suffer from dizziness take longer than people who do not, to perform a motor imagery task that involves implicit whole body rotation. Our prediction was that people in the ‘dizzy’ group would take longer at a left/right neck rotation judgment task but not a left/right hand judgment task, because actually performing the former, but not the latter, would exacerbate their dizziness. Secondly, we predicted that when dizzy participants responded to neck rotation images, responses would be greatest when images were in the upside-down orientation; an orientation with greatest dizzy-provoking potential. To test this idea, we used a case-control comparison design. One hundred and eighteen participants who suffered from dizziness and 118 age, gender, arm pain and neck pain matched controls took part in the study. Participants undertook two motor imagery tasks; a left/right neck rotation judgment task and a left/right hand judgment task. The tasks were completed using the Recognise program; an on-line reaction time task program. Images of neck rotation were shown in four different orientations; 0°, 90°, 180° and 270°. Participants were asked to respond to each ‘neck’ image identifying it as either ‘right neck rotation’ or a ‘left neck rotation’, or for hands, a right or a left hand. Results showed that participants in the ‘dizzy’ group were slower than controls at both tasks (p= 0.015, but this was not related to task (p= 0.498. Similarly, ‘dizzy’ participants were not proportionally worse at images of different orientations (p= 0.878. Our findings suggest impaired performance in dizzy people, an impairment that may be confined to motor imagery or may extend more generally.

  19. Increased body mass index is a predisposition for treatment by total hip replacement

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Sonne-Holm, Stig

    2005-01-01

    We investigated the radiological and epidemiological data of 4,151 subjects followed up from 1976 to 2003 to determine individual risk factors for hip osteoarthritis (OA), hip pain and/or treatment by total hip replacement (THR). Pelvic radiographs recorded in 1992 were assessed for evidence of hip......-joint degeneration and dysplasia. Sequential body mass index (BMI) measurements from 1976 to 1992, age, exposure to daily lifting and hip dysplasia were entered into logistic regression analyses. The prevalence of hip dysplasia ranged from 5.4% to 12.8% depending on the radiographical index used. Radiological hip OA...

  20. Bone marrow transplantation in the patients with malignant tumor. Studies on supralethal total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Tatsuno, Ikuro; Saito, Yasuo

    1984-11-01

    Based on evidence gained from ten patients of allogeneic bone marrow transplantation (BMT) and eight patients of autologous BMT, recent knowledge on literatures of BMT and total body irradiation (TBI) is summarized. Interstitial pneumonia after BMT has a strong correlation with TBI. Low dose-rate and fractionation of TBI are seemed to reduce the lung injury, thereby reducing the incidence of nonleukemia deaths. BMT is applied to not only acute leukemia, malignant lymphoma and solid tumors but also to chronic leukemia. It is emphasized that several of the important prognostic factors are within the control of the transplantation team.

  1. Indication of total body irradiation in adult allogeneic bone marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Kasai, Masaharu (Sapporo Hokuyu Hospital (Japan). Artificial Organ and Transplantation Hospital)

    1992-10-01

    Indication of total body irradiation (TBI) in adult allogeneic bone marrow transplantation was discussed in comparison with non-TBI method of busulfan and cyclophosphamide (BU+CY). Each method has unique advantages and disadvantages. Concerning adverse effects of interstitial pneumonia, liver dysfunction and so on, there are no significant differences in both methods. TBI method should be preferably indicated for lymphatic leukemias and leukemias involving central nervous systems. It is important to clarify what kinds of combination regimen depending on the type and the stage of disease are most suitable for the longer survival of patients with leukemia or aplastic anemia by multicentric randomized study. (author).

  2. An Acute Transverse Myelitis Attack after Total Body Irradiation: A Rare Case

    Directory of Open Access Journals (Sweden)

    Muzaffer Keklik

    2013-01-01

    Full Text Available Total body irradiation (TBI combined with chemotherapy is widely used as a pretreatment regimen of bone marrow transplantation (BMT in hematologic disorders. Late complications related to TBI as part of the conditioning regimen for hematopoietic stem cell transplantation have been revealed. Acute transverse myelitis (ATM is a neurological syndrome characterized by disorder of motor, sensorial, and autonomic nerves, and tracts at medulla spinalis, which is resulted from involvement of spinal cord. In this paper, we presented an ATM attack developed after TBI in a patient with acute lymphoblastic leukemia (ALL as it is a rarely seen case.

  3. Unscheduled DNA synthesis in spleen cells of mice exposed to low doses of total body irradiation

    International Nuclear Information System (INIS)

    Tuschl, H.; Kovac, R.; Hruby, E.

    1983-07-01

    Unscheduled DNA synthesis was induced by UV irradiation of spleen cells obtained from C 57 Bl mice after repeated total body irradiation of 0.05 Gy 60 Co (0.00125 Gy/mice) and determined autoradiographically. An enhancement in the ability for repair of UV induced DNA lesions was observed in cells of gamma irradiated animals. While the amount of 3 H-thymidine incorporated per cell was increased, the percentage of labeled cells remained unchanged. The present results are compared with previous data on low dose radiation exposure in men. (Author) [de

  4. Revisiting Biomarkers of Total-Body and Partial-Body Exposure in a Baboon Model of Irradiation.

    Directory of Open Access Journals (Sweden)

    Marco Valente

    Full Text Available In case of a mass casualty radiation event, there is a need to distinguish total-body irradiation (TBI and partial-body irradiation (PBI to concentrate overwhelmed medical resources to the individuals that would develop an acute radiation syndrome (ARS and need hematologic support (i.e., mostly TBI victims. To improve the identification and medical care of TBI versus PBI individuals, reliable biomarkers of exposure could be very useful. To investigate this issue, pairs of baboons (n = 18 were exposed to different situations of TBI and PBI corresponding to an equivalent of either 5 Gy 60Co gamma irradiation (5 Gy TBI; 7.5 Gy left hemibody/2.5 right hemibody TBI; 5.55 Gy 90% PBI; 6.25 Gy 80% PBI; 10 Gy 50% PBI, 15 Gy 30% PBI or 2.5 Gy (2.5 Gy TBI; 5 Gy 50% PBI. More than fifty parameters were evaluated before and after irradiation at several time points up to 200 days. A partial least square discriminant analysis showed a good distinction of TBI from PBI situations that were equivalent to 5 Gy. Furthermore, all the animals were pooled in two groups, TBI (n = 6 and PBI (n = 12, for comparison using a logistic regression and a non parametric statistical test. Nine plasmatic biochemical markers and most of hematological parameters turned out to discriminate between TBI and PBI animals during the prodromal phase and the manifest illness phase. The most significant biomarkers were aspartate aminotransferase, creatine kinase, lactico dehydrogenase, urea, Flt3-ligand, iron, C-reactive protein, absolute neutrophil count and neutrophil-to-lymphocyte ratio for the early period, and Flt3-ligand, iron, platelet count, hemoglobin, monocyte count, absolute neutrophil count and neutrophil-to-lymphocyte ratio for the ARS phase. These results suggest that heterogeneity could be distinguished within a range of 2.5 to 5 Gy TBI.

  5. Hyperfractionated total body irradiation for T-depleted HLA identical bone marrow transplants

    International Nuclear Information System (INIS)

    Latini, P.; Checcaglini, F.; Maranzano, E.; Aristei, C.; Panizza, B.M.; Gobbi, G.; Raymondi, C.; Aversa, F.; Martelli, M.F.

    1988-01-01

    Twenty patients suffering from malignant hemopathies (mean age 31.7 years) were given hyperfractionated total body irradiation (TBI) as conditioning for T-depleted HLA identical allogeneic bone marrow transplantation. At an average of 12 months (range of 4.5-22 months) follow-up there were two cases of early death and two cases (11%) of rejection. There were no cases of acute or chronic graft versus host disease nor cases of interstitial pneumonitis. The average time for durable engraftment was 22 days. Disease-free survival at 12 months was 65%. To improve the results and further reduce the percent of rejection, the authors propose intensifying the immunosuppressive conditioning by increasing the cyclophosphamide dose and that of TBI so that a total dose of 1560 cGy is reached. 35 refs.; 1 figure

  6. Why do total-body decay curves of iodine-labeled proteins begin with a delay

    International Nuclear Information System (INIS)

    Regoeczi, E.

    1987-01-01

    The initial delay that occurs in total-body radiation curves reaching their single-exponential slopes was analyzed from 106 experiments involving several mammalian species (guinea pig, mouse, rabbit, and rat) and plasma proteins (alpha 1-acid glycoprotein, antithrombin III, fibrinogen, immunoglobulin G, and transferrin) in 14 different combinations. The time interval (Td) between injection and the intercept of the slope with the full-dose value was adopted as a measure of curve nonideality. The overall mean Td was 6.6 h, but individual values showed a significant correlation to protein half-lives, whereby proteins of unequal metabolic properties exhibited different mean Td values. Targeting protein to the liver abolished delay. Choice of the isotope ( 125 I or 131 I) and size of the labeled protein had no influence on the magnitude of delay. Whole-body radiation curves of animals that received [ 125 I]iodotyrosines, Na 131 I, or 131 I-polyvinylpyrrolidone exhibited no initial delays. These results do not support the earlier notion that delay is caused by a redistribution of the labeled protein in the body to radiometrically more favorable sites. However, they are compatible with the assumption that delayed passage of a protein dose through the extracellular matrix and/or retarded transfer of proteolytic products from extravascular catabolic sites to plasma may be responsible for the phenomenon

  7. Total body retention of orally administered 47Ca in primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Mallette, L.E.; Sode, J.E.; Marx, S.J.; Georges, L.P.; Aurbach, G.D.

    1975-01-01

    Using a whole-body radiation detector, the total-body retention of 47 Ca 7 days after oral administration of the isotope to patients with various disorders of calcium metabolism was measured. The percent retention of 47 Ca given with 90 mg of unlabeled (carrier) calcium varied with the calcium metabolic status as follows: normals (n = 14), 33--43 percent (mean 38); primary hyperparathyroidism (n = 28), 32--74 percent (mean 52); idiopathic hypercalciuria (n = 9), 34--49 percent (mean 42); and hypercalcemia of other etiology (n = 3), 23--26 percent (mean 25). Almost half (13/28) of those with hyperparathyroidism showed a retention above 55 percent, distinguishing them from subjects with idiopathic hypercalciuria. Retention of 47 Ca correlated poorly with clinical measures of severity of hyperparathyroidism. When isotope was diluted with a smaller amount of carrier calcium (20 mg), retention was increased in normals (n = 5) to 46--54 percent (mean 50) and in hyperparathyroidism (n = 5) to 64--87 percent (mean 73). After surgical cure of hyperparathyroidism retention of isotope returned toward normal in 5 of 7 subjects. Whole-body retention of orally administered 47 Ca may prove useful in detecting hyperparathyroidism in subjects with mild hypercalcemia or hypercalciuria. (U.S.)

  8. In pediatric leukemia, dose evaluation according to the type of compensators in total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Yeon [Dongnam Inst. of Radiological and Medical science, Busan (Korea, Republic of); Kim, Chang Soo; Kim, Jung Hoon [Dept. of Radiological Science, College of Health Science, Catholic University of Busan, Busan (Korea, Republic of)

    2015-04-15

    Total body irradiation (TBI) and chemotherapy are the pre-treatment method of a stem cell transplantations of the childhood leukemia. in this study, we evaluate the Quantitative human body dose prior to the treatment. The MCNPX simulation program evaluated by changing the material of the tissue compensators with imitation material of pediatric exposure in a virtual space. As a result, first, the average skin dose with the material of the tissue compensators of Plexiglass tissue compensators is 74.60 mGy/min, Al is 73.96 mGy/min, Cu is 72.26 mGy/min and Pb 67.90 mGy/min respectively. Second, regardless of the tissue compensators material that organ dose were thyroid, gentile, digestive system, brain, lungs, kidneys higher in order. Finally, the ideal distance between body compensator and the patient were 50 cm aparting each other. In conclusion, tissue compensators Al, Cu, Pb are able to replace of the currently used in Plexiglass materials.

  9. Discriminative ability of total body bone-mineral measured by dual photon absorptiometry

    International Nuclear Information System (INIS)

    Gotfredsen, A.; Poedenphant, J.; Nilas, L.; Christiansen, C.

    1989-01-01

    We investigated the descriminative ability of total body bone-mineral expressed as the total body bone-density (TBBD) measured by dual photon absorptiometry (DPA) in 79 healthy premenopausal women, 27 healthy postmenopausal women, and 120 female osteoporotic fracture patients presenting with either Colles' fracture, vertebral fracture or femoral neck-fracture. TBBD was compared to the bone-mineral density of the lumbar spine (BMD spine ) also measured by DPA, and to the bone-mineral content of the forearms (BMC forearm ) measured by single photon absorptiometry (SPA). TBBD, BMD spine and BMC forearm showed that all the fracture patient groups had significantly reduced bone-mass. Using receiver operating characteristic (ROC) analysis, we found that TBBD had a tendency towards better discriminative ability than BMD spine or BMC forearm with regard to the discrimination between healthy premenopausal women and the three types of osteoporotic fractures. BMC forearm had an intermediate position, whereas BMD spine had the smallest discriminative ability. TBBD also discriminated better between healthy postmenopausal women and hip-fracture patients than BMD spine or BMC forearm , whereas there was no significant difference between the three methods regarding the discrimination between the healthy postmenopausal women and the Colles' and spinal fracture patients. We conclude that the TBBD measurement by DPA has a discriminative potential which is better than the local spine or forearm measurements. (author)

  10. Correlation of radial bone mineral content with total body calcium in chronic renal failure

    International Nuclear Information System (INIS)

    Cohn, S.H.; Ellis, K.J.; Caselnova, R.C.; Asad, S.N.; Letteri, J.M.

    1975-01-01

    Loss of bone mineral of the skeleton in renal disease can be measured directly by total body neutron activation analysis (TBNAA), and also by an absorptiometric technique applied to the appendicular skeleton (radius). In the present study the results of these two techniques are compared in 25 patients with renal insufficiency, 53 patients with end-stage renal failure on dialysis, and 24 normal control subjects. It is apparent that there is good correlation between total body calcium (TBCa) and bone mineral content (BMC) in all groups studied. The correlation in the normal contrast group was 0.944 as compared to 0.919 for the renal patients and 0.892 for patients with end-stage renal failure on dialysis. In order to measure the relative deficit in TBCa in individual patients from the absolute Ca measurement, it is necessary to normalize the data for sex, age, and skeletal size. For this purpose, an empirically derived relationship was used to predict the normal skeletal Ca in each subject, based on weight, height, sex, and age. The measured TBCa divided by the predicted TBCa is referred to as the calcium ratio. This ratio is useful in expressing the relative deficit of Ca in individual renal patients. In similar manner, BMC data were normalized, with the same relationship used to obtain BMC ratios. The normalization procedures allow both the TBCa and BMC measurements to be used to quantitate the Ca deficit in individual patients with renal insufficiency

  11. [Total body composition in adult patients with growth hormone deficiency before and after its administration].

    Science.gov (United States)

    Weiss, V; Krsek, M; Marek, J; Stĕpán, J; Malík, J

    2003-08-01

    Effect of growth hormone (GH) on the growth and development of children is generally known. Effects of GH in adults are favorable, though. The aim of the work was to verify effects of GH administration on body composition in adult patients with GH deficit (GHD). The authors examined 15 adult patients with GHD originated in 13 of them in adulthood and in two of them in childhood. Their mean age was 43.9 +/- 11.3 years, the mean body mass was 80.0 +/- 15.2 kg. The GH deficit was verified by the stimulation insulin tolerance test. For the period of 12 months, they were subcutaneously administered recombinant human GH in a substitution dose of 0.5 to 1.5 IU/m2 body surface/day. A stable substitution of the hormone was applied for the period of at least six months in all these patients provided any deficit of other hormones had not been demonstrated. The examination by whole-body dosimeter Lunar DPX-L was made in the patients before the GH treatment began and after 12 months of therapy. It enabled to determine the amount of lean body mass (LBM) and fatty mass. After 12 months of GH treatment the mean level of insulin-like growth factor (IGF-I) was increased (P = 0.002). A statistically significant increase of total LBM (48.6 +/- 9.8 vs. 50.8 +/- 9.9 kg, P = 0.004) developed, the fatty mass did not change. Nine of these 15 patients were further followed and the administration of GH proceeded for six months. The densitometric examination was repeated, but no change of LBM was observed. The administration of GH was halted and after the period of 12 months the whole-body densitometric examination was done. The increase of LBM lasted. The amount of fat mass did not change, a decrease of fatty mass was observed after the GH administration ended. After 12 months of GH treatment there was also an increase of maximal output reached on bicycle ergometer (157.3 +/- 34.2 vs. 197.5 +/- 68.1 W, P = 0.006). A positive correlation between LBM and maximal output reached on bicycle

  12. Exploring the Relationship between Skeletal Mass and Total Body Mass in Birds.

    Science.gov (United States)

    Martin-Silverstone, Elizabeth; Vincze, Orsolya; McCann, Ria; Jonsson, Carl H W; Palmer, Colin; Kaiser, Gary; Dyke, Gareth

    2015-01-01

    Total body mass (TBM) is known to be related to a number of different osteological features in vertebrates, including limb element measurements and total skeletal mass. The relationship between skeletal mass and TBM in birds has been suggested as a way of estimating the latter in cases where only the skeleton is known (e.g., fossils). This relationship has thus also been applied to other extinct vertebrates, including the non-avian pterosaurs, while other studies have used additional skeletal correlates found in modern birds to estimate TBM. However, most previous studies have used TBM compiled from the literature rather than from direct measurements, producing values from population averages rather than from individuals. Here, we report a new dataset of 487 extant birds encompassing 79 species that have skeletal mass and TBM recorded at the time of collection or preparation. We combine both historical and new data for analyses with phylogenetic control and find a similar and well-correlated relationship between skeletal mass and TBM. Thus, we confirm that TBM and skeletal mass are accurate proxies for estimating one another. We also look at other factors that may have an effect on avian body mass, including sex, ontogenetic stage, and flight mode. While data are well-correlated in all cases, phylogeny is a major control on TBM in birds strongly suggesting that this relationship is not appropriate for estimating the total mass of taxa outside of crown birds, Neornithes (e.g., non-avian dinosaurs, pterosaurs). Data also reveal large variability in both bird skeletal and TBM within single species; caution should thus be applied when using published mass to test direct correlations with skeletal mass and bone lengths.

  13. In vivo prompt gamma activation analysis facility for total body nitrogen and cadmium

    International Nuclear Information System (INIS)

    Munive, Marco; Solis, Jose; Revilla, Angel

    2008-01-01

    Full text: Prompt Neutron Activation Analysis (PGNAA) is a technique that could have medical applications, like determination of body's contents of protein and heavy metals in vivo. The in vivo PGNAA facility, contains a neutron source (Cf-252) with safety device, a compartment for animal irradiation, and a gamma rays detecting system based on the NaI(Tl) detector with an analytical software. The prompt gamma rays were emitted after 10 -15 s of the interaction, so they don't produce radioactive waste, and have a characteristics energy for each element, i.e. a strong peak at 2.24 MeV is observed for H. The facility has been used with laboratory mice. Water-filled phantom placed in the neutron beam was used to system calibration. Three study groups of 5 mice each one were selected and were feed with a different diet and the total body nitrogen (TBN) of the mice was monitored with the facility. The diet produced a different TBN for each group. Some mice drunk diluted water with Cl 2 Cd, so the presence of Cd was detected in the mouse. The minimum Cd concentration that the system can detect was 20 ppm. The total dose (neutron and gamma dose was measured from TLDs and simulated by MNCP-4B in the sample compartment during the irradiation time (5 minutes) is less than 2.5 mSv. This total dose is low than the dose from other analytical radiological techniques (25 a 50 mSv). (author)

  14. Post-middle Miocene Tuffs of Bodie Hills and Mono Basin, California: Paleomagnetic Reference Directions and Vertical Axis Rotation

    Science.gov (United States)

    Lindeman, J. R.; Pluhar, C. J.; Farner, M. J.

    2013-12-01

    The relative motions of the Pacific and North American plates about the Sierra Nevada-North American Euler pole is accommodated by dextral slip along the San Andreas Fault System (~75%) and the Walker Lane-Eastern California Shear Zone system of faults, east of the Sierra Nevada microplate (~25%). The Bodie Hills and Mono Basin regions lie within the Walker Lane and partially accommodate deformation by vertical axis rotation of up to 60o rotation since ~9.4 Ma. This region experienced recurrent eruptive events from mid to late Miocene, including John et al.'s (2012) ~12.05 Ma Tuff of Jack Springs (TJS) and Gilbert's (1968) 11.1 - 11.9 Ma 'latite ignimbrite' east of Mono Lake. Both tuffs can be identified by phenocrysts of sanidine and biotite in hand specimens, with TJS composed of a light-grey matrix and the latite ignimbrite composed of a grey-black matrix. Our paleomagnetic results show these units to both be normal polarity, with the latite ignimbrite exhibiting a shallow inclination. TJS's normal polarity is consistent with emplacement during subchron C5 An. 1n (12.014 - 12.116 Ma). The X-ray fluorescence analyses of fiamme from TJS in Bodie Hills and the latite ignimbrite located east of Mono Lake reveal them both to be rhyolites with the latite ignimbrite sharing elevated K composition seen in the slightly younger Stanislaus Group (9.0 - 10.2 Ma). We establish a paleomagnetic reference direction of D = 352.8o I = 42.7o α95 = 7.7o n = 5 sites (42 samples) for TJS in the Bodie Hills in a region hypothesized by Carlson (2012) to have experienced low rotation. Our reference for Gilbert's latite ignimbrite (at Cowtrack Mountain) is D = 352.9o I = 32.1o α95 = 4.7o. This reference locality is found on basement highland likely to have experienced less deformation then the nearby Mono Basin since ignimbrite emplacement. Paleomagnetic results from this latite ignimbrite suggests ~98.2o × 5.5o of clockwise vertical axis rotation of parts of eastern Mono Basin since

  15. Total body fat, proinflammatory cytokines and insulin resistance in Indian subjects

    International Nuclear Information System (INIS)

    Yajnik, C.S.; Lubree, H.G.; Rege, S.S.; Bhat, D.S.; Raut, K.N.; Panchanadikar, A.S.; Joglekar, C.B.; Naik, S.S.; Shetty, P.; Yudkin, J.; Kurpad, A.V.

    2002-01-01

    We studied cardiovascular risk factors in 30 to 50 year old Indian men in three geographical locations (rural, urban slums and urban middle class) in relation to their body fat. A total of 1,222 subjects, selected by stratified random sampling were screened: 39 reported diabetic or hypertensive. Of the remaining subjects 600 were randomly selected for further testing. This is a report 441 men studied (149 rural, 142 slums, 150 urban middle class). The mean age of these men was 38 y rural, 38 y urban slums, 41 y urban middle class, mean BMI 21.0 kg/m 2 , 22.3 kg/m 2 and 24.3 kg/m 2 respectively, mean body fat percent by bio-impedance 20.4%, 22.5% and 30.4% and by Deuterated water was 19.9%, 21.6% and 27.2% respectively. A 75 g oral glucose tolerance test (WHO 1985) showed no diabetes in rural subjects, while 4% urban slum dwellers and 10 in urban middle class were diabetic; 9% rural men had IGT, compared to 12% in urban slums and 20% in urban middle class. Hypertension (blood pressure ≥ 140/90 mm Bg) was present in 2% rural men, 4% in urban slums and in 10% men in urban middle class. Mean plasma cholesterol concentration was 148 mg% in rural, 53 mg% in urban slums and 64 mg% in urban middle class, mean plasma triglyceride concentrations were 82 mg%, 95 mg% and 108 mg% respectively. All cardiovascular risk factors were strongly related to measures of obesity (body fat % and waist hip ratio). On multivariate analysis 2h plasma glucose (OGTT) concentration and blood pressure were additionally related to geographical location (urban middle class>slums>rural). Our results suggest that urbanisation increases the risk of glucose intolerance and hypertension independent of the body fat percent or its central distribution. This suggests there may he additional environmental factors in the urban environment increasing the risk of diabetes over and above the effect of body fat. (author)

  16. Total body fat, proinflammatory cytokines and insulin resistance in Indian subjects

    Energy Technology Data Exchange (ETDEWEB)

    Yajnik, C S; Lubree, H G; Rege, S S; Bhat, D S; Raut, K N; Panchanadikar, A S; Joglekar, C B; Naik, S S [Diabetest Unit, KEM Hospital Resarch Centre, Pune (India); Shetty, P [London School of Hygiene and Tropical Medicine, London (United Kingdom); Yudkin, J [International Health and Medical Education Centre, UCL, London (United Kingdom); Kurpad, A V [St. John' s Medical College, Bangalore (India)

    2002-07-01

    We studied cardiovascular risk factors in 30 to 50 year old Indian men in three geographical locations (rural, urban slums and urban middle class) in relation to their body fat. A total of 1,222 subjects, selected by stratified random sampling were screened: 39 reported diabetic or hypertensive. Of the remaining subjects 600 were randomly selected for further testing. This is a report 441 men studied (149 rural, 142 slums, 150 urban middle class). The mean age of these men was 38 y rural, 38 y urban slums, 41 y urban middle class, mean BMI 21.0 kg/m{sup 2}, 22.3 kg/m{sup 2} and 24.3 kg/m{sup 2} respectively, mean body fat percent by bio-impedance 20.4%, 22.5% and 30.4% and by Deuterated water was 19.9%, 21.6% and 27.2% respectively. A 75 g oral glucose tolerance test (WHO 1985) showed no diabetes in rural subjects, while 4% urban slum dwellers and 10 in urban middle class were diabetic; 9% rural men had IGT, compared to 12% in urban slums and 20% in urban middle class. Hypertension (blood pressure {>=} 140/90 mm Bg) was present in 2% rural men, 4% in urban slums and in 10% men in urban middle class. Mean plasma cholesterol concentration was 148 mg% in rural, 53 mg% in urban slums and 64 mg% in urban middle class, mean plasma triglyceride concentrations were 82 mg%, 95 mg% and 108 mg% respectively. All cardiovascular risk factors were strongly related to measures of obesity (body fat % and waist hip ratio). On multivariate analysis 2h plasma glucose (OGTT) concentration and blood pressure were additionally related to geographical location (urban middle class>slums>rural). Our results suggest that urbanisation increases the risk of glucose intolerance and hypertension independent of the body fat percent or its central distribution. This suggests there may he additional environmental factors in the urban environment increasing the risk of diabetes over and above the effect of body fat. (author)

  17. Comparison of total body water determinations in lactating women by anthropometry, water displacement, and deuterium isotope dilution

    International Nuclear Information System (INIS)

    Wong, W.; Butte, N.; Lee, L.; Garza, C.; Klein, P.

    1986-01-01

    To expand the limited data on the total body water in lactating women, the authors have determined total body water contents, in eight subjects from anthropometric measurements, water displacement, and isotope dilution of deuterium oxide. On the day of the study, their skinfold thicknesses were measured over the biceps and triceps muscles and at the suprailiac and subscapular areas. Their body densities were measured by water displacement. Deuterium oxide was administered orally at 100 mg/kg of body weight. One predose milk sample was collected from each subject. The milk samples were defatted by centrifugation and the milk water was reduced to hydrogen gas for hydrogen isotope ratio measurements by gas-isotope-ratio mass spectrometry. The results indicated that total body water in lactating women estimated from anthropometric measurements was 49.7 +/- 3.3% of body weight, by water displacement was 54.9 +/- 7.2%, and by isotope dilution was 50.8 +/- 3.7%

  18. Accumulation of Inertial Sensory Information in the Perception of Whole Body Yaw Rotation.

    Science.gov (United States)

    Nesti, Alessandro; de Winkel, Ksander; Bülthoff, Heinrich H

    2017-01-01

    While moving through the environment, our central nervous system accumulates sensory information over time to provide an estimate of our self-motion, allowing for completing crucial tasks such as maintaining balance. However, little is known on how the duration of the motion stimuli influences our performances in a self-motion discrimination task. Here we study the human ability to discriminate intensities of sinusoidal (0.5 Hz) self-rotations around the vertical axis (yaw) for four different stimulus durations (1, 2, 3 and 5 s) in darkness. In a typical trial, participants experienced two consecutive rotations of equal duration and different peak amplitude, and reported the one perceived as stronger. For each stimulus duration, we determined the smallest detectable change in stimulus intensity (differential threshold) for a reference velocity of 15 deg/s. Results indicate that differential thresholds decrease with stimulus duration and asymptotically converge to a constant, positive value. This suggests that the central nervous system accumulates sensory information on self-motion over time, resulting in improved discrimination performances. Observed trends in differential thresholds are consistent with predictions based on a drift diffusion model with leaky integration of sensory evidence.

  19. Cytogenetic studies on recipients of allogeneic bone marrow transplants after fractionated total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, N; Goedde-Salz, E; Loeffler, H [Christian-Albrechts-Univ., Kiel (Germany, F.R.)

    1985-06-01

    Cytogenetic findings from the bone marrow (BM) and the peripheral blood (PB) of nine consecutive patients after allogeneic bone marrow transplantation (BMT) for acute or chronic myelogenous leukaemia are reported. After a conditioning regimen consisting of cyclophosphamide and fractionated total body irradiation (TBI) given in five or six fractions of 2 Gy, persistence of host cells was detected in four out of seven cases with permanent engraftment. While one of these patients relapsed 4 months after host cells had been found in BM and PB, the other patients stayed relapse-free 124, 257 and 347 d after grafting. Before transplantation, the leukaemic cells in all three cases carried unique cytogenetic abnormalities giving the opportunity to distinguish the leukaemic population from chromosomally non-aberrant cells thought to represent residual normal host cells. As the persisting host cells after BMT lacked any cytogenetic abnormalities, it is suggested that they were members of residual normal clones not involved in the leukaemic process.

  20. The effect of total-body γ-irradiation on pigeons

    International Nuclear Information System (INIS)

    Gadhia, P.K.; Shah, V.C.; Desai, R.

    1979-01-01

    A study of the effects of total-body 60 Coγ radiation (200 to 2000 rad) on the common pigeon (Columba livia) has indicated a LD 50/30 of 950 +- 50 rad. There were no deaths before 6 days and the peak frequency in average deaths occurred 9 days after irradiation. Most of the birds showed small changes in activity or behaviour in the first five days. A histopathological study was made of femoral bone marrow from irradiated (1000 rad) pigeons sacrificed 1 to 18 days post-irradiation. Slight aplasia was observed on the first day after irradiation, moderately marked on the third day and extensive on the fourth and fifth days. At the end of the second week regeneration was observed as the primitive lymphocyte-like cells were differentiating into granulocytes and erythrocytes. (UK)

  1. Increased body mass index is a predisposition for treatment by total hip replacement

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Sonne-Holm, Stig

    2005-01-01

    -joint degeneration and dysplasia. Sequential body mass index (BMI) measurements from 1976 to 1992, age, exposure to daily lifting and hip dysplasia were entered into logistic regression analyses. The prevalence of hip dysplasia ranged from 5.4% to 12.8% depending on the radiographical index used. Radiological hip OA...... prevalence was 1.0--2.5% in subjects or=60 years of age. While radiological OA was significantly influenced by hip dysplasia in men and hip dysplasia and age in women, the risk of THR being performed was only influenced by BMI assessed in 1976. Hip......We investigated the radiological and epidemiological data of 4,151 subjects followed up from 1976 to 2003 to determine individual risk factors for hip osteoarthritis (OA), hip pain and/or treatment by total hip replacement (THR). Pelvic radiographs recorded in 1992 were assessed for evidence of hip...

  2. Radiobiological considerations in the treatment of neuroblastoma by total body irradiation

    International Nuclear Information System (INIS)

    Wheldon, T.E.; O'Donoghue, J.; Gregor, A.; Livingstone, A.; Wilson, L.; West of Scotland Health Boards, Glasgow

    1986-01-01

    Neuroblastoma is a radiosensitive neoplasm for which total body irradiation (TBI) is presently under clinical consideration. Collated data on the radiobiology of human neuroblastoma cells in vitro indicates moderate cellular radiosensitivity and low capacity for accumulation of sublethal damage. Mathematical studies incorporating these parameters suggest that low dose fractionated TBI is unlikely to achieve significant levels of tumour cell kill. When high dose TBI is used in conjuction with bone marrow rescue a tumour 'log cell kill' of 4-5 should be achievable. This effect would be additional to that acheived by chemotherapy. Fractionated TBI with bone marrow rescue may be curative for some patients in clinical remission who are presently destined to relapse. (Auth.)

  3. Cobalt-60 total body irradiation dosimetry at 220 cm source-axis distance

    International Nuclear Information System (INIS)

    Glasgow, G.P.; Mill, W.B.

    1980-01-01

    Adults with acute leukemia are treated with cyclophosphamide and total body irradiation (TBI) followed by autologous marrow transplants. For TBI, patients seated in a stand angled 45 0 above the floor are treated for about 2 hours at 220 cm source-axis distance (SAD) with sequential right and left lateral 87 cm x 87 cm fields to a 900 rad mid-pelvic dose at about 8 rad/min using a 5000 Ci cobalt unit. Maximum (lateral) to minimum (mid-plane) dose ratios are: hips--1.15, shoulders--1.30, and head--1.05, which is shielded by a compensator filter. Organ doses are small intestine, liver and kidneys--1100 rad, lung--1100 to 1200 rad, and heart--1300 rad. Verification dosimetry reveals the prescribed dose is delivered to within +-5%. Details of the dosimetry of this treatment are presented

  4. Pilot production of the wedge filter for the TBI (total body irradiation)

    International Nuclear Information System (INIS)

    Ikezaki, Hiromi; Ikeda, Ikuo; Maruyama, Yasushi; Nako, Yasunobu; Tonari, Ayako; Kusuda, Junko; Takayama, Makoto

    2007-01-01

    Total body irradiation (TBI) is performed by various methods, such as a long SSD method and a translational couch method. For patient safety in carrying out TBI, the patient should be placed on the supine position and prone position near the floor. TBI is performed from 2 opposite ports (AP/PA) with a linear accelerator (10 MV X-ray). We experimented with a wedge filter for TBI created by us, which makes dose distribution to a floor uniform. The wedge filter, made of iron alloy, was attached to the linear accelerator. In designing the wedge filter, thickness of the lead-made wedge filter can be calculated numerically from the ratio of linear attenuation coefficient of iron alloy and lead. In measuring the dose profile for a phantom of 20 cm thick, dose homogeneity less than 10% was proved by the wedge filter for TBI. (author)

  5. Relative effect of radiation dose rate on hemopoietic and nonhemopoietic lethality of total-body irradiation

    International Nuclear Information System (INIS)

    Peters, L.J.; McNeill, J.; Karolis, C.; Thames, H.D. Jr.; Travis, E.L.

    1986-01-01

    Experiments were undertaken to determine the influence of dose rate on the toxicity of total-body irrdiation (TBI) with and without syngeneic bone-marrow rescue in mice. The results showed a much greater dose-rate dependence for death from nonhemopoietic toxicity than from bone-marrow ablation, with the ratio of LD 50 's increasing from 1.73 at 25 cGy/min to 2.80 at 1 cGy/min. At the higher dose rates, dose-limiting nonhemopoietic toxicity resulted from late organ injury, affecting the lungs, kidneys, and liver. At 1 cGy/min the major dose-limiting nonhemopoietic toxicity was acute gastrointestinal injury. The implications of these results in the context of TBI in preparation for bone-marrow transplantation are discussed. 15 refs., 4 figs

  6. Disturbances in dental development after total body irradiation in bone marrow transplant recipients

    International Nuclear Information System (INIS)

    Dahlloef, G.B.; Barr, M.; Bolme, P.; Modeer, T.; Loennqvist, B.R.; Ringden, O.; Heimdahl, A.

    1988-01-01

    The dental status of 16 children who had been treated with bone marrow transplantation (BMT) for serious bone marrow diseases was followed for up to 6 years. Several types of disturbances in dental development were observed in children who had been conditioned with total body irradiation (TBI) at 10 Gy before BMT. Thus, impaired root development that caused short V-shaped roots was found in all patients, a complete failure of root development and premature apical closure were found in five patients, enamel hypoplasia was observed in four patients, and microdontia was observed in three patients conditioned with TBI. Patients younger than 6 years of age at BMT exhibited the most severe and extensive dental aberrations. The TBI at 10 Gy appeared to be the major cause of the disturbances found

  7. Total body irradiation and autologus bone marrow transplantation in acute leukemias and non Hodgkin-lymphomas

    Energy Technology Data Exchange (ETDEWEB)

    Corvo, R; Franzone, P; Scarpati, D; Congiu, M; Carella, A

    1986-01-01

    From january 1984 to may 1986, 31 patients, 15 ANLL, 8 ALL (in remission status) and 8 NHL (6 in remission, 2 in relapse) have been treated with chemo-radiotherapy (cyclophosphamide 60 mg/kg x 2 days + total body irradiation (TBI): 10 Gy/3 fr./3 days with 4 Gy boost testicular dose in ALL) and autologous bone marrow transplantation (BMT). Seventeen patients are alive, 16 in remission: 9 (60%) ANLL, 2 (25%) ALL, 5 (62%) NHL (median 8+ months, follow up 1+ /29+); 2 patients presented interstitial pneumonitis (6.45%). In this series, very good results have been achieved in ANLL, where no relapse was noted, encouraging achievements in NHL, with 4/8 relapse. Advantages and disadvanteges of autologus relative to allogenic BMT, and of conditioning regimen with or without TBI are discussed.

  8. Blood volume, blood pressure and total body sodium: internal signalling and output control

    DEFF Research Database (Denmark)

    Bie, P

    2009-01-01

    Total body sodium and arterial blood pressure (ABP) are mutually dependent variables regulated by complex control systems. This review addresses the role of ABP in the normal control of sodium excretion (NaEx), and the physiological control of renin secretion. NaEx is a pivotal determinant of ABP......, and under experimental conditions, ABP is a powerful, independent controller of NaEx. Blood volume is a function of dietary salt intake; however, ABP is not, at least not in steady states. A transient increase in ABP after a step-up in sodium intake could provide a causal relationship between ABP...... and the regulation of NaEx via a hypothetical integrative control system. However, recent data show that subtle sodium loading (simulating salty meals) causes robust natriuresis without changes in ABP. Changes in ABP are not necessary for natriuresis. Normal sodium excretion is not regulated by pressure. Plasma...

  9. Treatment of chronic granulocytic leukemia by chemotherapy, total body irradiation and allogeneic bone marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Doney, K; Buckner, C D; Sale, G E; Ramberg, R; Boyd, C; Thomas, E D [Fred Hutchinson Cancer Research Institute; Washington Univ., Seattle (USA). School of Medicine)

    1978-01-01

    Fourteen patients with chronic granulocytic leukemia received bone marrow grafts from HLA identical siblings. Ten patients were in blast crisis prior to grafting, three were in an accelerated phase of their disease, and one was aplastic secondary to chemotherapy. Prior to transplant all patients were conditioned with chemotherapy including cyclophosphamide plus 1,000 rad of total body irradiation. Ten patients achieved engraftment while four died 1 to 26 days after marrow infusion without functioning grafts. Two patients reveived a second infusion of donor marrow because of delayed engraftment. Neither marrow cell dose nor presence of myelofibrosis correlated with succesful engraftment. Three out of ten engrafted patients developed graft-versus-host disease. Interstitial pneumonia occurred in seven patients. The immediate cause of death was bacterial septicemia in six patients. All evidence of leukemia disappeared in nine out of ten evaluable patients. The median survival was 43 days. One patient had a complete remission of 16 months duration.

  10. Treatment of chronic granulocytic leukemia by chemotherapy, total body irradiation and allogeneic bone marrow transplantation

    International Nuclear Information System (INIS)

    Doney, K.; Buckner, C.D.; Sale, G.E.; Ramberg, R.; Boyd, C.; Thomas, E.D.; Washington Univ., Seattle

    1978-01-01

    Fourteen patients with chronic granulocytic leukemia received bone marrow grafts from HLA identical siblings. Ten patients were in blast crisis prior to grafting, three were in an accelerated phase of their disease, and one was aplastic secondary to chemotherapy. Prior to transplant all patients were conditioned with chemotherapy including cyclophosphamide plus 1,000 rad of total body irradiation. Ten patients achieved engraftment while four died 1 to 26 days after marrow infusion without functioning grafts. Two patients reveived a second infusion of donor marrow because of delayed engraftment. Neither marrow cell dose nor presence of myelofibrosis correlated with succesful engraftment. Three out of ten engrafted patients developed graft-versus-host disease. Interstitial pneumonia occurred in seven patients. The immediate cause of death was bacterial septicemia in six patients. All evidence of leukemia disappeared in nine out of ten evaluable patients. The median survival was 43 days. One patient had a complete remission of 16 months duration. (Author)

  11. Cytogenetic studies on recipients of allogeneic bone marrow transplants after fractionated total body irradiation

    International Nuclear Information System (INIS)

    Schmitz, N.; Goedde-Salz, E.; Loeffler, H.

    1985-01-01

    Cytogenetic findings from the bone marrow (BM) and the peripheral blood (PB) of nine consecutive patients after allogeneic bone marrow transplantation (BMT) for acute or chronic myelogenous leukaemia are reported. After a conditioning regimen consisting of cyclophosphamide and fractionated total body irradiation (TBI) given in five or six fractions of 2 Gy, persistence of host cells was detected in four out of seven cases with permanent engraftment. While one of these patients relapsed 4 months after host cells had been found in BM and PB, the other patients stayed relapse-free 124, 257 and 347 d after grafting. Before transplantation, the leukaemic cells in all three cases carried unique cytogenetic abnormalities giving the opportunity to distinguish the leukaemic population from chromosomally non-aberrant cells thought to represent residual normal host cells. As the persisting host cells after BMT lacked any cytogenetic abnormalities, it is suggested that they were members of residual normal clones not involved in the leukaemic process. (author)

  12. Fetal subcutaneous tissue measurements in pregnancy as a predictor of neonatal total body composition.

    Science.gov (United States)

    O'Connor, Clare; Doolan, Anne; O'Higgins, Amy; Segurado, Ricardo; Sheridan-Pereiraet, Margaret; Turner, Michael J; Stuart, Bernard; Kennelly, Máireád M

    2014-10-01

    The purpose of this study was to examine the relationship between prenatal measures of subcutaneous tissue as surrogate markers of fetal nutritional status and correlate them with neonatal total body composition. This prospective longitudinal study of 62 singleton pregnancies obtained serial biometry and subcutaneous tissue measurements at 28, 33 and 38 weeks gestation. These measurements were then correlated with neonatal body composition, which was analysed using the PEAPOD™ Infant Body Composition System (Cosmed USA, Concord, CA, USA). At 38 weeks gestation, fetal abdominal subcutaneous tissue (FAST) in millimetres was significantly associated with infant fat mass at delivery (+64 g per mm of FAST, p < 0.001). Thigh fat (TF) at 28 weeks gestation was associated with infant fat mass at delivery (+79 g/mm TF, p = 0.023). TF at 38 weeks gestation was associated with infant fat mass (+63/mm TF, p = 0.004). TF and FAST at 38 weeks were also predictive of both birth weight and increased abdominal circumference (AC) (p = 0.001) with FAST measurement predicting an additional 5.7 mm in AC per millimetre of FAST (p = 0.002) and TF predicting an additional 6.9 mm per mm of TF (p = 0.002). We believe that this study further validates the use of prenatal measures of subcutaneous tissue and may help to highlight fetuses at risk of newborn adiposity and metabolic syndrome. © 2014 John Wiley & Sons, Ltd.

  13. In vivo dosimetry for total body irradiation: five‐year results and technique comparison

    Science.gov (United States)

    Warry, Alison J.; Eaton, David J.; Collis, Christopher H.; Rosenberg, Ivan

    2014-01-01

    The aim of this work is to establish if the new CT‐based total body irradiation (TBI) planning techniques used at University College London Hospital (UCLH) and Royal Free Hospital (RFH) are comparable to the previous technique at the Middlesex Hospital (MXH) by analyzing predicted and measured diode results. TBI aims to deliver a homogeneous dose to the entire body, typically using extended SSD fields with beam modulation to limit doses to organs at risk. In vivo dosimetry is used to verify the accuracy of delivered doses. In 2005, when the Middlesex Hospital was decommissioned and merged with UCLH, both UCLH and the RFH introduced updated CT‐planned TBI techniques, based on the old MXH technique. More CT slices and in vivo measurement points were used by both; UCLH introduced a beam modulation technique using MLC segments, while RFH updated to a combination of lead compensators and bolus. Semiconductor diodes were used to measure entrance and exit doses in several anatomical locations along the entire body. Diode results from both centers for over five years of treatments were analyzed and compared to the previous MXH technique for accuracy and precision of delivered doses. The most stable location was the field center with standard deviations of 4.1% (MXH), 3.7% (UCLH), and 1.7% (RFH). The least stable position was the ankles. Mean variation with fraction number was within 1.5% for all three techniques. In vivo dosimetry can be used to verify complex modulated CT‐planned TBI, and demonstrate improvements and limitations in techniques. The results show that the new UCLH technique is no worse than the previous MXH one and comparable to the current RFH technique. PACS numbers: 87.55.Qr, 87.56.N‐ PMID:25207423

  14. Behavioural consequences of an 8 Gy total body irradiation in mice: Regulation by interleukin-4

    International Nuclear Information System (INIS)

    Van der Meeren, A.; Lebaron-Jacobs, L.

    2001-01-01

    The effects of an 8 Gy γ total body irradiation (TBI) on exploration and locomotion activities as well as temperature were studied in C57BL6/J mice. Survival, body weight, and blood cell counts were also assessed in irradiated mice treated with placebo or interleukin (IL)-4. The efficacy of IL-4 treatment on improvement in exploration activity was evaluated. The study was carried out from 3 h to 30 days following exposure. Our results showed a biphasic response to irradiation concerning the exploration activity of mice. Irradiated mice had reduced activity as early as 3 h after exposure, with recovery of activity within 24 h. The exploration activity again decreased 4 days after irradiation and the recovery occurred slowly after day 17. IL-4 ameliorated the exploration status in mice in both phases. The locomotion activity was studied using a telemetry apparatus. A similar pattern to that of the exploration data was observed, with a minimal activity observed between days 13 and 17. A radiation-induced hypothermia was also noticed over the same time period. (author)

  15. Study on the immunological suppressive mechanisms of the cyclophosphamide-administration and total body irradiation

    International Nuclear Information System (INIS)

    Wakizaka, Yoshitaka; Uchino, Junichi; Yang, Zi-Bo.

    1994-01-01

    High dose-cyclophosphamide (CP) administration and total body irradiation (TBI) are often used for bone marrow transplantation in order to eradicate the residual tumor cells and to induce the immunological tolerance in the recipients. But CP is difficult to use as an immunosuppressant because this drug has indefinite effects on host's immune status depending on the dose, i.e. augment the humoral antibody production in small dosage and inhibit the rejective reaction in large dosage. Thus we study on the immunological mechanisms of this drug and the TBI used often with CP for bone marrow transplantation in leukemic patients. 150 mg/kg of CP was administered via tail vein, and 3 Gy (300 rads) of X-ray was irradiated. CP could suppress the host's cellular immunity within 5 days after administration but TBI could within 3 days. Reversely, CP augmented the cellular immunity since 5 days after treatment. CP damaged the IL-2 production irreversibely, but IL-3 production was inhibited by CP for only a few days and recovered rapidly. These characters were thought to be a big help for the implantation and development of the multipotent stem cells in the recipient's body after transplantation. (author)

  16. Behavioural consequences of an 8 Gy total body irradiation in mice: Regulation by interleukin-4

    Energy Technology Data Exchange (ETDEWEB)

    Van der Meeren, A.; Lebaron-Jacobs, L. [Inst. de Protection et de Surete Nucleaire, Dept. de Protection de la sante de l' Homme et de Dosimetrie, Section Autonome de Radiobiologie Appliquee a la Medecine, IPSN, Fontenay-aux-Roses (France)

    2001-02-01

    The effects of an 8 Gy {gamma} total body irradiation (TBI) on exploration and locomotion activities as well as temperature were studied in C57BL6/J mice. Survival, body weight, and blood cell counts were also assessed in irradiated mice treated with placebo or interleukin (IL)-4. The efficacy of IL-4 treatment on improvement in exploration activity was evaluated. The study was carried out from 3 h to 30 days following exposure. Our results showed a biphasic response to irradiation concerning the exploration activity of mice. Irradiated mice had reduced activity as early as 3 h after exposure, with recovery of activity within 24 h. The exploration activity again decreased 4 days after irradiation and the recovery occurred slowly after day 17. IL-4 ameliorated the exploration status in mice in both phases. The locomotion activity was studied using a telemetry apparatus. A similar pattern to that of the exploration data was observed, with a minimal activity observed between days 13 and 17. A radiation-induced hypothermia was also noticed over the same time period. (author)

  17. Total body irradiation in intensive treatment necessitating bone marrow graft, of malignant hematological diseases

    International Nuclear Information System (INIS)

    Regnier, R.; Van Houtte, P.; Piron, A.; Debusscher, L.; Strijckmans, P.

    1990-01-01

    From 1980 to 1988, 65 consecutive patients were treated with a program of intensive chemotherapy and total body irradiation (TBI) for malignant hematological diseases at the Institut Jules-Bordet. Results were analyzed according to different prognostic factors as well as to the radiation technique; 3 different schedules were used: 3 fractions of 2.66 Gy given in one day at 3-h intervals, 6 daily fractions of 2 Gy in 6 days and 7 fractions of 2.25 Gy in 8 days. The second radiation schedule appears to give the best results as relapses were higher with the 1-day program and there was an increase in later effects and early deaths with 7 fractions of 2.25 Gy. Nevertheless, the results indicate that after administration of 5 or 6 times 2 Gy TBI, there might be possible benefit in treating certain parts of the body by radiation, those in particular that could be sanctuary sites for malignant cells from chemotherapy. The authors propose a simple and easy way of uniformizing the radiation schedule to carry out a multicentric trial [fr

  18. The influence of x-ray energy on lung dose uniformity in total-body irradiation

    International Nuclear Information System (INIS)

    Ekstrand, Kenneth; Greven, Kathryn; Wu Qingrong

    1997-01-01

    Purpose: In this study we examine the influence of x-ray energy on the uniformity of the dose within the lung in total-body irradiation treatments in which partial transmission blocks are used to control the lung dose. Methods and Materials: A solid water phantom with a cork insert to simulate a lung was irradiated by x-rays with energies of either 6, 10, or 18 MV. The source to phantom distance was 3.9 meters. The cork insert was either 10 cm wide or 6 cm wide. Partial transmission blocks with transmission factors of 50% were placed anterior to the cork insert. The blocks were either 8 or 4 cm in width. Kodak XV-2 film was placed in the midline of the phantom to record the dose. Midplane dose profiles were measured with a densitometer. Results: For the 10 cm wide cork insert the uniformity of the dose over 80% of the block width varied from 6.6% for the 6 MV x-rays to 12.2% for the 18 MV x-rays. For the 6 cm wide cork insert the uniformity was comparable for all three x-ray energies, but for 18 MV the central dose increased by 9.4% compared to the 10 cm wide insert. Conclusion: Many factors must be considered in optimizing the dose for total-body irradiation. This study suggests that for AP/PA techniques lung dose uniformity is superior with 6 MV irradiation. The blanket recommendation that the highest x-ray energy be used in TBI is not valid for all situations

  19. Establishment of Early Endpoints in Mouse Total-Body Irradiation Model.

    Directory of Open Access Journals (Sweden)

    Amory Koch

    Full Text Available Acute radiation sickness (ARS following exposure to ionizing irradiation is characterized by radiation-induced multiorgan dysfunction/failure that refers to progressive dysfunction of two or more organ systems, the etiological agent being radiation damage to cells and tissues over time. Radiation sensitivity data on humans and animals has made it possible to describe the signs associated with ARS. A mouse model of total-body irradiation (TBI has previously been developed that represents the likely scenario of exposure in the human population. Herein, we present the Mouse Intervention Scoring System (MISS developed at the Veterinary Sciences Department (VSD of the Armed Forces Radiobiology Research Institute (AFRRI to identify moribund mice and decrease the numbers of mice found dead, which is therefore a more humane refinement to death as the endpoint. Survival rates were compared to changes in body weights and temperatures in the mouse (CD2F1 male TBI model (6-14 Gy, 60Co γ-rays at 0.6 Gy min-1, which informed improvements to the Scoring System. Individual tracking of animals via implanted microchips allowed for assessment of criteria based on individuals rather than by group averages. From a total of 132 mice (92 irradiated, 51 mice were euthanized versus only four mice that were found dead (7% of non-survivors. In this case, all four mice were found dead after overnight periods between observations. Weight loss alone was indicative of imminent succumbing to radiation injury, however mice did not always become moribund within 24 hours while having weight loss >30%. Only one survivor had a weight loss of greater than 30%. Temperature significantly dropped only 2-4 days before death/euthanasia in 10 and 14 Gy animals. The score system demonstrates a significant refinement as compared to using subjective assessment of morbidity or death as the endpoint for these survival studies.

  20. Calibration of whole-body counters for transuranic radionuclides by using total-body donations to the United States Transuranium Registry

    International Nuclear Information System (INIS)

    Palmer, H.E.; Heid, K.R.; Breitenstein, B.D.; Durbin, P.W.; McInroy, J.F.

    1985-01-01

    One of the many benefits of the whole-body donation programme of the United States Transuranium Registry is the calibration of whole-body counters by measuring a donated body containing radioactivity before radiochemical analysis of the body occurs. These measurements have provided the best existing calibration factors for measuring 241 Am and 239 Pu in the skeleton of living people. In one case where the body contained an easily measurable quantity of 241 Am, the 241 Am content was found to be the same for identical bones on the right and left sides of the body. The bones from the right side of the body and every other vertebrae were radiochemically analysed and the bones from the left side were reserved. These latter have a known quantity of naturally distributed 241 Am based on the analysis of bones from the right side. These reserved bones are being incorporated into tissue equivalent body parts for future calibrations and interlaboratory comparisons. The measurements on the total body and the reserved bones have already been very useful in determining the contribution of skeletal activity to that of lung measurements and determining a calibration factor for measuring 239 Pu deposited in the skeleton. In the future it is planned to periodically make in vivo measurements on those people participating in the total-body donation programme so that calibration factors can be obtained for lung and liver content after subsequent analysis of these tissues. (author)

  1. Total body fat, pro-inflammatory cytokines and insulin resistance in Indian subjects

    Energy Technology Data Exchange (ETDEWEB)

    Yajnik, C S [Diabetes Unit, KEM Hospital Research Centre, Pune (India); Yudkin, J S [Whittington Hospital, University College of London, London (United Kingdom); Shetty, P S [London School of Hygiene and Tropical Medicine, London (United Kingdom); Kurpad, A [St. John' s Medical College, Bangalore (India)

    1999-07-01

    There is a growing epidemic of insulin resistance syndrome (IRS) in Indians. We postulate that increased susceptibility of the urban Indians to insulin resistance is a result of a tendency to increased fat deposition from the time of intrauterine life (thrifty phenotype), exaggerated in the urban environment by a positive energy balance. The pro-inflammatory cytokines secreted by the inflammatory cells as well by the adipose tissue could aggravate insulin resistance and endothelial damage and therefore, increase the susceptibility to type 2 diabetes and coronary heart disease (CHD) independent of the previously proposed glucose fatty acid cycle mechanism. In a preliminary study, we propose to make detailed measurements of the proposed mechanisms in a selected population from 3 geographical locations in and near the city of Pune, India and also validate simple 'epidemiologic' measurements of body composition with 'reference' measurements. One hundred men (30 to 50y) each from the three geographical locations (rural, urban slum-dwellers and urban middle class in Pune) will be studied for: (i) Body composition: Anthropometric and bioimpedance measurement of total body fat (to be calibrated against deuterated water in 30 subjects from each location), and muscle mass by anthropometry and urinary creatinine excretion; (ii) Body fat distribution by subscapular- triceps ratio, waist-hip ratio; (iii) Metabolic: Glucose tolerance and insulin resistance variables (insulin, lipids, NEFA) and leptin; (iv) Endothelial markers: e-Selectin and von Willebrand Factor (vWF); (v) Inflammatory markers and pro-inflammatory cytokines: C-reactive protein (CRP), Interleukin-6 (IL-6) and tumour necrosis factor (TNF- {alpha}); (vi) Energy Balance: Assessment of nutritional intake (calories, carbohydrates, proteins and fats, n3 and n6 fatty acids) and physical activity by a questionnaire. Insulin resistance variables, endothelial markers, cytokines and obesity parameters will be compared in

  2. Total body fat, pro-inflammatory cytokines and insulin resistance in Indian subjects

    International Nuclear Information System (INIS)

    Yajnik, C.S.; Yudkin, J.S.; Shetty, P.S.; Kurpad, A.

    1999-01-01

    There is a growing epidemic of insulin resistance syndrome (IRS) in Indians. We postulate that increased susceptibility of the urban Indians to insulin resistance is a result of a tendency to increased fat deposition from the time of intrauterine life (thrifty phenotype), exaggerated in the urban environment by a positive energy balance. The pro-inflammatory cytokines secreted by the inflammatory cells as well by the adipose tissue could aggravate insulin resistance and endothelial damage and therefore, increase the susceptibility to type 2 diabetes and coronary heart disease (CHD) independent of the previously proposed glucose fatty acid cycle mechanism. In a preliminary study, we propose to make detailed measurements of the proposed mechanisms in a selected population from 3 geographical locations in and near the city of Pune, India and also validate simple 'epidemiologic' measurements of body composition with 'reference' measurements. One hundred men (30 to 50y) each from the three geographical locations (rural, urban slum-dwellers and urban middle class in Pune) will be studied for: (i) Body composition: Anthropometric and bioimpedance measurement of total body fat (to be calibrated against deuterated water in 30 subjects from each location), and muscle mass by anthropometry and urinary creatinine excretion; (ii) Body fat distribution by subscapular- triceps ratio, waist-hip ratio; (iii) Metabolic: Glucose tolerance and insulin resistance variables (insulin, lipids, NEFA) and leptin; (iv) Endothelial markers: e-Selectin and von Willebrand Factor (vWF); (v) Inflammatory markers and pro-inflammatory cytokines: C-reactive protein (CRP), Interleukin-6 (IL-6) and tumour necrosis factor (TNF- α); (vi) Energy Balance: Assessment of nutritional intake (calories, carbohydrates, proteins and fats, n3 and n6 fatty acids) and physical activity by a questionnaire. Insulin resistance variables, endothelial markers, cytokines and obesity parameters will be compared in the 3

  3. Dosimetry and verification of 60Co total body irradiation with human phantom and semiconductor diodes

    Directory of Open Access Journals (Sweden)

    Allahverdi Mahmoud

    2007-01-01

    Full Text Available Total Body Irradiation (TBI is a form of radiotherapy used for patients prior to bone marrow or stem cell transplant to destroy any undetectable cancer cells. The dosimetry characteristics of a 60 Co unit for TBI were studied and a simple method for the calculation of the prescribed dose for TBI is presented. Dose homogeneity was verified in a human phantom. Dose measurements were made in water phantom (30 x 30 x 30 cm 3 , using farmer ionization chamber (0.6 cc, TM30010, PTW and a parallel plate ionization chamber (TM23343, PTW. Point dose measurements for AP/PA irradiation were measured in a human phantom using silicon diodes (T60010L, PTW. The lung dose was measured with an ionization chamber (0.3 cc, TM31013. The validity of the proposed algorithm was checked at TBI distance using the human phantom. The accuracy of the proposed algorithm was within 3.5%. The dose delivered to the mid-lobe of the lung was 14.14 Gy and it has been reduced to 8.16 Gy by applying the proper shield. Dose homogeneity was within ±7% for all measured points. The results indicate that a good agreement between the total prescribed and calculated midplane doses can be achieved using this method. Therefore, it could be possible to use calculated data for TBI treatments.

  4. Dose rate and dose fractionation studies in total body irradiation of dogs

    International Nuclear Information System (INIS)

    Kolb, H.J.; Netzel, B.; Schaffer, E.; Kolb, H.

    1979-01-01

    Total body irradiation (TBI) with 800-900 rads and allogeneic bone marrow transplantation according to the regimen designated by the Seattle group has induced remissions in patients with otherwise refractory acute leukemias. Relapse of leukemia after bone marrow transplantation remains the major problem, when the Seattle set up of two opposing 60 Co-sources and a low dose rate is used in TBI. Studies in dogs with TBI at various dose rates confirmed observations in mice that gastrointestinal toxicity is unlike toxicity against hemopoietic stem cells and possibly also leukemic stem cells depending on the dose rate. However, following very high single doses (2400 R) and marrow infusion acute gastrointestinal toxicity was not prevented by the lowest dose rate studied (0.5 R/min). Fractionated TBI with fractions of 600 R in addition to 1200 R (1000 rads) permitted the application of total doses up to 300 R followed by marrow infusion without irreversible toxicity. 26 dogs given 2400-3000 R have been observed for presently up to 2 years with regard to delayed radiation toxicity. This toxicity was mild in dogs given single doses at a low dose rate or fractionated TBI. Fractionated TBI is presently evaluated with allogeneic transplants in the dog before being applied to leukemic patients

  5. Benefits of online in vivo dosimetry for single-fraction total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Eaton, David J., E-mail: davideaton@nhs.net [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom); Warry, Alison J. [Department of Radiotherapy Physics, University College London Hospital, London (United Kingdom); Trimble, Rachel E.; Vilarino-Varela, Maria J.; Collis, Christopher H. [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom)

    2014-01-01

    Use of a patient test dose before single-fraction total body irradiation (TBI) allows review of in vivo dosimetry and modification of the main treatment setup. However, use of computed tomography (CT) planning and online in vivo dosimetry may reduce the need for this additional step. Patients were treated using a supine CT-planned extended source-to-surface distance (SSD) technique with lead compensators and bolus. In vivo dosimetry was performed using thermoluminescent dosimeters (TLDs) and diodes at 10 representative anatomical locations, for both a 0.1-Gy test dose and the treatment dose. In total, 28 patients were treated between April 2007 and July 2013, with changes made in 10 cases (36%) following test dose results. Overall, 98.1% of measured in vivo treatment doses were within 10% of the prescribed dose, compared with 97.0% of test dose readings. Changes made following the test dose could have been applied during the single-fraction treatment itself, assuming that the dose was delivered in subportions and online in vivo dosimetry was available for all clinically important anatomical sites. This alleviates the need for a test dose, saving considerable time and resources.

  6. Benefits of online in vivo dosimetry for single-fraction total body irradiation

    International Nuclear Information System (INIS)

    Eaton, David J.; Warry, Alison J.; Trimble, Rachel E.; Vilarino-Varela, Maria J.; Collis, Christopher H.

    2014-01-01

    Use of a patient test dose before single-fraction total body irradiation (TBI) allows review of in vivo dosimetry and modification of the main treatment setup. However, use of computed tomography (CT) planning and online in vivo dosimetry may reduce the need for this additional step. Patients were treated using a supine CT-planned extended source-to-surface distance (SSD) technique with lead compensators and bolus. In vivo dosimetry was performed using thermoluminescent dosimeters (TLDs) and diodes at 10 representative anatomical locations, for both a 0.1-Gy test dose and the treatment dose. In total, 28 patients were treated between April 2007 and July 2013, with changes made in 10 cases (36%) following test dose results. Overall, 98.1% of measured in vivo treatment doses were within 10% of the prescribed dose, compared with 97.0% of test dose readings. Changes made following the test dose could have been applied during the single-fraction treatment itself, assuming that the dose was delivered in subportions and online in vivo dosimetry was available for all clinically important anatomical sites. This alleviates the need for a test dose, saving considerable time and resources

  7. Lung damage following bone marrow transplantation after hyperfractionated total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Latini, Paolo; Aristei, Cynthia; Checcaglini, Franco; Maranzano, Ernesto; Panizza, B.M.; Perrucci, Elisabetta (University and Hospital, Policlinico, Perugia (Italy). Radiation Oncology Service); Aversa, Franco; Martelli, M.F. (University and Hospital, Policlinico, Perugia (Italy). Department of Haematology); Raymondi, Carlo (University and Hospital, Policlinico, Perugia (Italy). Radiation Physics Service)

    1991-10-01

    From July 1985 to December 1989, 72 evaluable patients aged 6-51 (median age 27) suffering from hematological malignancies received allo-geneic bone marrow transplant (BMT) depleted of T-lymphocytes to reduce risks of graft-versus-host-disease (GvHD); 57 were matched and 15 mis-matched. Three different conditioning regiments were used in an effort to enhance cytoreduction without increase extramedullary toxicity. Mis-matched patients were treated with more immunosuppressive regimens. Total body irradiation (TBI) was given in 3 doses/day, 5 h apart over 4 days for a total of 12 fractions. The dose to the lungs was 14.4, 15.6 and 9 Gy according to the conditioning regimen. The incidence of inter-stitial pneumonia (IP) was 12.3 percent in matched and 46.7 in mis-matched patients. The results seem to indicate that lung toxicity is correlated with the intensity of the conditioning regimen, the stage of disease and, in mismatched patients, with the degree of human leucocyte antigen (HLA) disparity and the poor post-BMT reconstitution, rather than the radiotherapy dose delivered to the lungs. On the contrary, the hyperfractionated scheme adopted, the absence of GvHD and, perhaps, the post-TBI administration of cyclophosphamide all seem to have contributed to the low incidence of IP in the matched patients. (author). 30 refs.; 5 figs.; 1 tab.

  8. Lung damage following bone marrow transplantation after hyperfractionated total body irradiation

    International Nuclear Information System (INIS)

    Latini, Paolo; Aristei, Cynthia; Checcaglini, Franco; Maranzano, Ernesto; Panizza, B.M.; Perrucci, Elisabetta; Aversa, Franco; Martelli, M.F.; Raymondi, Carlo

    1991-01-01

    From July 1985 to December 1989, 72 evaluable patients aged 6-51 (median age 27) suffering from hematological malignancies received allo-geneic bone marrow transplant (BMT) depleted of T-lymphocytes to reduce risks of graft-versus-host-disease (GvHD); 57 were matched and 15 mis-matched. Three different conditioning regiments were used in an effort to enhance cytoreduction without increase extramedullary toxicity. Mis-matched patients were treated with more immunosuppressive regimens. Total body irradiation (TBI) was given in 3 doses/day, 5 h apart over 4 days for a total of 12 fractions. The dose to the lungs was 14.4, 15.6 and 9 Gy according to the conditioning regimen. The incidence of inter-stitial pneumonia (IP) was 12.3 percent in matched and 46.7 in mis-matched patients. The results seem to indicate that lung toxicity is correlated with the intensity of the conditioning regimen, the stage of disease and, in mismatched patients, with the degree of human leucocyte antigen (HLA) disparity and the poor post-BMT reconstitution, rather than the radiotherapy dose delivered to the lungs. On the contrary, the hyperfractionated scheme adopted, the absence of GvHD and, perhaps, the post-TBI administration of cyclophosphamide all seem to have contributed to the low incidence of IP in the matched patients. (author). 30 refs.; 5 figs.; 1 tab

  9. Total body irradiation in the bone marrow transplantation in leukemia:an experience

    International Nuclear Information System (INIS)

    Zapatero, A.; Martin de Vidales, C.; Pinar, B.; Marin, A.; Cerezo, L.; Dominguez, P.; Perez, A.

    1996-01-01

    The purpose of this report was to evaluate long-term survival and morbidity of fractioned total body irradiation (TBI) prior to allogeneicbone marrow transplantation (BMT) for leukemia. From June 1985 to May 1992, 94 patients with acute leukemia and chronic myelogenous leukemia (CML), were treated with high dose cyclophosphamide(CY) and fractionated TBI to a total dose of 12 Gy in six fractions prior to allogeneic BMT. The Kaplan-Meier 5-year overall survival and disease-free survival were 53% +-6 and 48%+- respectively for patients with standard risk disease (first remission of acute leukemia and first chronic phase of CML), and 24%+-7 and 21%+-6 for patients with more advanced disease (p=3D0.01). The incidence of interstitial pneumonitis (IP), venoocclusive disease of the liver (VOD) and grade=3D>II acute graft-versus-host disease (GVHD) were respectively 15%, 29% and 51%. Fractionated TBI combined with high dose CY before allogeneic BMT for leukemia is an effective treatment in prolonging relapse-free survival witha low incidence of lung toxicity. (Author) 13 refs

  10. Severe Pulmonary Toxicity After Myeloablative Conditioning Using Total Body Irradiation: An Assessment of Risk Factors

    International Nuclear Information System (INIS)

    Kelsey, Chris R.; Horwitz, Mitchell E.; Chino, Junzo P.; Craciunescu, Oana; Steffey, Beverly; Folz, Rodney J.; Chao, Nelson J.; Rizzieri, David A.; Marks, Lawrence B.

    2011-01-01

    Purpose: To assess factors associated with severe pulmonary toxicity after myeloablative conditioning using total body irradiation (TBI) followed by allogeneic stem cell transplantation. Methods and Materials: A total of 101 adult patients who underwent TBI-based myeloablative conditioning for hematologic malignancies at Duke University between 1998 and 2008 were reviewed. TBI was combined with high-dose cyclophosphamide, melphalan, fludarabine, or etoposide, depending on the underlying disease. Acute pulmonary toxicity, occurring within 90 days of transplantation, was scored using Common Terminology Criteria for Adverse Events version 3.0. Actuarial overall survival and the cumulative incidence of acute pulmonary toxicity were calculated via the Kaplan-Meier method and compared using a log-rank test. A binary logistic regression analysis was performed to assess factors independently associated with acute severe pulmonary toxicity. Results: The 90-day actuarial risk of developing severe (Grade 3-5) pulmonary toxicity was 33%. Actuarial survival at 90 days was 49% in patients with severe pulmonary toxicity vs. 94% in patients without (p < 0.001). On multivariate analysis, the number of prior chemotherapy regimens was the only factor independently associated with development of severe pulmonary toxicity (odds ratio, 2.7 per regimen). Conclusions: Severe acute pulmonary toxicity is prevalent after TBI-based myeloablative conditioning regimens, occurring in approximately 33% of patients. The number of prior chemotherapy regimens appears to be an important risk factor.

  11. Linac-based total body irradiation (TBI) with volumetric modulated arc therapy (VMAT)

    Science.gov (United States)

    Tas, B.; Durmus, I. F.; Okumus, A.; Uzel, O. E.

    2017-02-01

    To evaluate dose distribution of Volumetric modulated arc therapy (VMAT) planning tecnique using Versa HD® lineer accelerator to deliver Total Body Irradiation (TBI) on the coach. Eight TBI patient's Treatment Planning System (TPS) were performed with dual arc VMAT for each patient. The VMAT-TBI consisted of three isocentres and three dual overlapping arcs. The prescribed dose was 12 Gy. Mean dose to lung and kidney were restricted less than 10 Gy and max. dose to lens were restricted less than 6 Gy. The plans were verified using 2D array and ion chamber. The comparison between calculation and measurement were made by γ-index analysis and absolute dose. An average total delivery time was determined 923±34 seconds and an average MU was determined 2614±228 MUs for dual arc VMAT. Mean dose to lungs was 9.7±0.2 Gy, mean dose to kidneys was 8.8±0.3 Gy, max. dose to lens was 5.5±0.3 Gy and max. dose was 14.6±0.3 Gy, HI of PTV was 1.13±0.2, mean dose to PTV was 12.6±1.5 Gy and mean γ-index pass rate was %97.1±1.9. The results show that the tecnique for TBI using VMAT on the treatment coach is feasible.

  12. Analysis of Surface Dose Refer to Distance between Beam Spoiler and Patient in Total Body Irradiation

    International Nuclear Information System (INIS)

    Choi, Jong Hwan; Kim, Jong Sik; Choi, Ji Min; Shin, Eun Hyuk; Song, Ki Won; Park, Young Hwan

    2007-01-01

    Total body irradiation is used to kill the total malignant cell and for immunosuppression component of preparatory regimens for bone-marrow restitution of patients. Beam spoiler is used to increase the dose to the superficial tissues. This paper finds the property of the distance between beam spoiler and patient. Set-up conditions are 6 MV-Xray, 300 MU, SAD = 400 cm, field size = 40 x 40 cm 2 . The parallel plate chamber located in surface, midpoint and exit of solid water phantom. The surface dose is measured while the distance between beam spoiler and patient is altered. Because it should be found proper distance. The solid water phantom is fixer and beam spoiler is moving. Central dose of phantom is 10.7 cGy and exit dose is 6.7 cGy. In case of distance of 50 cm to 60 cm between beam spoiler and solid water phantom, incidence dose is 14.58-14.92 cGy. Therefore, The surface dose was measured 99.4-101% with got near most to the prescription dose. In clinical case, distance between beam spoiler and patient affect surface dose. If once 50-60 cm of distance between beam spoiler and patient, surface dose of patient got near prescription dose. It would be taken distance between beam spoiler and patient into account in clinical therapy.

  13. A numerical method for reorientation of rotating tidally deformed viscoelastic bodies

    NARCIS (Netherlands)

    Hu, H.; van der Wal, W.; Vermeersen, L.L.A.

    2017-01-01

    Existing approaches for simulating the true polar wander (TPW) of a viscoelastic body can be divided into three categories: (i) a linear dynamic approach which uses the linearized Liouville equation (e.g., Wu and Peltier (1984) and Mitrovica et al. (2005)); (ii) a nonlinear dynamic approach which

  14. Reconstructing rotations and rigid body motions from exact point correspondences through reflections

    NARCIS (Netherlands)

    Fontijne, D.; Dorst, L.; Dorst, L.; Lasenby, J.

    2011-01-01

    We describe a new algorithm to reconstruct a rigid body motion from point correspondences. The algorithm works by constructing a series of reflections which align the points with their correspondences one by one. This is naturally and efficiently implemented in the conformal model of geometric

  15. Total-body irradiation and bone-marrow transplantation - first observations on clinical tolerance

    International Nuclear Information System (INIS)

    Gocheva, L.; Sergieva, K.; Koleva, I.; Mlachkova, D.; Michailov, G.; Avramova, B.

    2004-01-01

    About 50 000 bone-marrow transplantations (BMT) are performed annually at the present stage in numerous clinical centers all over the world. The Bulgarian experience in total-body irradiation (TBI) with following BMT is rather scarce. The routine TBI procedures in the oncological practice in the country date back just to 2001. The aim of the present publication is to describe the Bulgarian experience and the first impressions from the clinical tolerance of the total-body irradiation (TBI) with subsequent allogeneic peripheral stem cell transplantation (PSCT). Patient characteristics are presented in detail, including their distribution with respect to sex, age, primary diagnose, recurrence number till BMT, patient status during BMT performance (clinical hematological remission or relapse), as well as the basic parameters of the conditioning regime including TBI with subsequent allogeneic PSCT. The position of the patient and the applied radiotherapeutic equipment are described as well as the TBI schemes, respectively 5 fractions of 2 Gy per day for two patients and 3-day irradiation with 6 fractions (two fractions with a 6-hour interval between them) for the rest of the patients. The total dose (TD) of 10 Gy is realized for all patients. The clinical tolerance of 7 patients subjected to TBI and allogeneic PSCT is discussed. All patients were tolerable to the TBI treatment and had no serious problems. The radiotherapy was interrupted only in the case of the first two patients due to slight gastro-intestinal reactions. The first days of radiation were accompanied with a light degree of headache, nausea and vomiting, which were successfully overcome by granisetron. Diarrhea syndrome and mucositis to the II-III degree were developed subsequently without parotitis development. On the days 0 and +1 of the clinical protocol transplantation was realized of non- T-cell-depleted grafts (in 5 patients) and T-cell-depleted grafts (in 2 patients), which had no serious

  16. Abdominal Obesity and their association with Total Body: Fat Distribution and Composition. Case of Algerian Teenager Male high school students

    Directory of Open Access Journals (Sweden)

    Mohammed Zerf

    2017-06-01

    Full Text Available Purpose: Our aim attempted to esteem the impact of abdominal fat on body fat distribution or composition related to total body fat as recommended weight loss among High School Students. Material: For the proposed, 100 male students from the Algerian high school Education Sector's mandate Sidi Bel Abbes, participate in the present study. Their average age 16±1.52 years, distributed into homogeneous groups, according to their body fat percent categories. Examined by saving tests (Body Fat Percentage (BFP - Abdominal circumference (WC - Body mass index (BMI. Results: Based on the test data and the analysis statistics applied, we confirm: a Abdominal obesity is excess body gain correlate with total fat BMI. It highly affected body composition reported as additional fat for overweight in compare with acceptable according to Ideal BFP categories. b Abdominal obesity is an amount deep fat correlates to total BFP. It higher influenced the distribution of total body fat reported as additional excess fat among overweight category compared to the acceptable group. c Waist circumference (WC is the leading marker of abdominal fat deposits located in the central region of the body. While the combination of body mass index (BMI and waist circumference (WC, reflects the combined effects of body build (fat or fatness in individuals at higher risk of excessive body fat. Conclusions: founded on the differences acquired by the research team. We highlight that abdominal obesity is strongly connected to larger WC relate to total body gain located as excess inordinate fatness BMI or fat distribution BFP among our overall sample. Evidence, which guides us to recommend our adolescent students to intensification their hours of sports practice, in order to avoid the consequences of abdominal obesity gain. Announced in the present study as excess abdominal adiposity more metabolically active. Requiring the control of body weight loss (BFP or BMI strongly correlates to

  17. On sharp vorticity gradients in elongating baroclinic eddies and their stabilization with a solid-body rotation

    Science.gov (United States)

    Sutyrin, Georgi G.

    2016-06-01

    Wide compensated vortices are not able to remain circular in idealized two-layer models unless the ocean depth is assumed to be unrealistically large. Small perturbations on both cyclonic and anticyclonic eddies grow slower if a middle layer with uniform potential vorticity (PV) is added, owing to a weakening of the vertical coupling between the upper and lower layers and a reduction of the PV gradient in the deep layer. Numerical simulations show that the nonlinear development of the most unstable elliptical mode causes self-elongation of the upper vortex core and splitting of the deep PV anomaly into two corotating parts. The emerging tripolar flow pattern in the lower layer results in self-intensification of the fluid rotation in the water column around the vortex center. Further vortex evolution depends on the model parameters and initial conditions, which limits predictability owing to multiple equilibrium attractors existing in the dynamical system. The vortex core strips thin filaments, which roll up into submesoscale vortices to result in substantial mixing at the vortex periphery. Stirring and damping of vorticity by bottom friction are found to be essential for subsequent vortex stabilization. The development of sharp PV gradients leads to nearly solid-body rotation inside the vortex core and formation of transport barriers at the vortex periphery. These processes have important implications for understanding the longevity of real-ocean eddies.

  18. Impact of dietary vitamin A interventions on total body stores in Thai lactating women

    International Nuclear Information System (INIS)

    Wasanwisut, E.; West, K.P.

    1997-01-01

    Vitamin A deficiency (VAD) is increasingly being recognized as a public health problem among pregnant and lactating women in developing countries. This proposed study will be a randomized trial to evaluate the efficacy of consuming provitamin A-rich foods in one prepared, on-site meal per weekday for 3 months on total body vitamin A stores and other aspects of vitamin A status in marginally nourished lactating women in rural Northeast Thailand. Approximately 400 lactating women, 2-18 months post-partum, will be screened in the population for marginal vitamin A status by a tier of indicators beginning from low intake or history of night blindness or impaired dark adaptability followed by low serum retinol. Assuming a prevalence of low serum retinol of ∼20%, 90 women will be identified and recruited, matched by serum retinol and month post-partum and randomized in a block fashion into three groups to receive daily cooked (fat-added) meal and snack with (1) dark green leafy and yellow/orange vegetables and fruits, (2) beta-carotene- enriched rice chips and (3) non-enriched rice chips. Groups 1 and 2 will receive ∼3.6 mg of beta-carotene per day. Prior to and following the intervention hepatic vitamin A reserves will be estimated by isotopic dilution techniques and other indicators of vitamin A status. In addition, serum C-reactive protein and maternal anthropometry will be measured. Food consumption data based on 24-hour recall for 3 randomized days will be collected every 2 weeks to assess routine intakes of vitamin A, fat and other nutrients. Morbidity will be monitored on a weekly basis throughout the study. Between-group comparisons will provide a basis for (1) estimating the adequacy of local diets to improve or maintain total body stores of vitamin A in women during lactation and (2) assessing the validity and responsiveness of widely used measures of vitamin A status in this high-risk group

  19. The carcinogenic risk of high dose total body irradiation in non-human primates

    International Nuclear Information System (INIS)

    Broerse, J.J.; Bartstra, R.W.; Bekkum, D.W. van; Hage, M.H. van der; Zurcher, C.; Zwieten, M.J. van; Hollander, C.F.

    2000-01-01

    High dose total body irradiation (TBI) in combination with chemotherapy, followed by rescue with bone marrow transplantation (BMT), is increasingly used for the treatment of haematological malignancies. With the increasing success of this treatment and its current introduction for treating refractory autoimmune diseases the risk of radiation carcinogenesis is of growing concern. Studies on turnout induction in non-human primates are of relevance in this context since the response of this species to radiation does not differ much from that in man. Since the early sixties, studies have been performed on acute effects in Rhesus monkeys and the protective action of bone marrow transplantation after irradiation with X-rays (average total body dose 6.8 Gy) and fission neutrons (average dose 3.4 Gy). Of those monkeys, which were irradiated and reconstituted with autologous bone marrow, 20 animals in the X-irradiated group and nine animals in the neutron group survived more than 3 years. A group of 21 non-irradiated Rhesus monkeys of a comparable age distribution served as controls. All animals were regularly screened for the occurrence of neoplasms. Complete necropsies were performed after natural death or euthanasia. At post-irradiation intervals of 4-21 years an appreciable number of tumours was observed. In the neutron irradiated group eight out of nine animals died with one or more malignant tumours. In the X-irradiated group this fraction was 10 out of 20. The tumours in the control group, in seven out of the 21 animals, appeared at much older a-e compared with those in the irradiated cohorts. The histogenesis of the tumours was diverse with a preponderance of renal carcinoma, sarcomas among which osteosarcormas, and malignant glomus tumours in the irradiated groups. When corrected for competing risks, the carcinogenic risk of TBI in the Rhesus monkeys is similar to that derived from the studies of the Japanese atomic bomb survivors. The increase of the risk by a

  20. Fiber-coupled Al_2O_3:C radioluminescence dosimetry for total body irradiations

    International Nuclear Information System (INIS)

    Buranurak, S.; Andersen, C.E.

    2016-01-01

    In vivo dosimetry can be important and relevant in radiotherapy, especially when commissioning new treatment techniques at hospitals. This study investigates the potential use of fiber-coupled radioluminescence (RL) dosimetry based on Al_2O_3:C or organic plastic scintillators for this purpose in the context of Total Body Irradiations (TBIs) where patients are treated with large fields of 6 or 18 MV photons at an extended source-to-surface distance (SSD). The study shows that Al_2O_3:C dosimetry using the saturated-RL protocol may be suitable for real-time in vivo dosimetry during TBI treatments from the perspective of the good agreement with alanine dosimetry and other critical phantom tests, including the ability to cope with the large stem signal experienced during TBI treatments at extended SSD. In contrast, the chromatic stem removal technique often used for organic plastic scintillators did not work well in large fields with the tested calibration procedure and instrumentation. An apparent dose-rate effect discussed in a previous study of the RL properties of Al_2O_3:C (Andersen et al., 2011) was found to have resulted from an overlooked dead time problem in the counting system, and this potential caveat can therefore be removed from the list of potential problems associated with fiber-coupled Al_2O_3:C dosimetry using the saturated-RL protocol. This further has implications for TBI dosimetry using the RL Al_2O_3:C system due to large dose-rate differences between calibrations at the iso-center and in vivo measurements at extended source-to-surface distances. - Highlights: • Fiber-coupled dosimetry can be used for measurements during total body irradiations. • An apparent dose-effect associated with radioluminescence from Al2O3:C was resolved. • The gated-counting stem removal procedure worked well for Al2O3:C in pulsed accelerator beams. • The chromatic stem removal procedure did not work well with the tested instrumentation and organic plastic

  1. Total body surface area overestimation at referring institutions in children transferred to a burn center.

    Science.gov (United States)

    Swords, Douglas S; Hadley, Edmund D; Swett, Katrina R; Pranikoff, Thomas

    2015-01-01

    Total body surface area (TBSA) burned is a powerful descriptor of burn severity and influences the volume of resuscitation required in burn patients. The incidence and severity of TBSA overestimation by referring institutions (RIs) in children transferred to a burn center (BC) are unclear. The association between TBSA overestimation and overresuscitation is unknown as is that between TBSA overestimation and outcome. The trauma registry at a BC was queried over 7.25 years for children presenting with burns. TBSA estimate at RIs and BC, total fluid volume given before arrival at a BC, demographic variables, and clinical variables were reviewed. Nearly 20 per cent of children arrived from RIs without TBSA estimation. Nearly 50 per cent were overestimated by 5 per cent or greater TBSA and burn sizes were overestimated by up to 44 per cent TBSA. Average TBSA measured at BC was 9.5 ± 8.3 per cent compared with 15.5 ± 11.8 per cent as measured at RIs (P < 0.0001). Burns between 10 and 19.9 per cent TBSA were overestimated most often and by the greatest amounts. There was a statistically significant relationship between overestimation of TBSA by 5 per cent or greater and overresuscitation by 10 mL/kg or greater (P = 0.02). No patient demographic or clinical factors were associated with TBSA overestimation. Education efforts aimed at emergency department physicians regarding the importance of always calculating TBSA as well as the mechanics of TBSA estimation and calculating resuscitation volume are needed. Further studies should evaluate the association of TBSA overestimation by RIs with adverse outcomes and complications in the burned child.

  2. Emesis as a Screening Diagnostic for Low Dose Rate (LDR) Total Body Radiation Exposure.

    Science.gov (United States)

    Camarata, Andrew S; Switchenko, Jeffrey M; Demidenko, Eugene; Flood, Ann B; Swartz, Harold M; Ali, Arif N

    2016-04-01

    Current radiation disaster manuals list the time-to-emesis (TE) as the key triage indicator of radiation dose. The data used to support TE recommendations were derived primarily from nearly instantaneous, high dose-rate exposures as part of variable condition accident databases. To date, there has not been a systematic differentiation between triage dose estimates associated with high and low dose rate (LDR) exposures, even though it is likely that after a nuclear detonation or radiologic disaster, many surviving casualties would have received a significant portion of their total exposure from fallout (LDR exposure) rather than from the initial nuclear detonation or criticality event (high dose rate exposure). This commentary discusses the issues surrounding the use of emesis as a screening diagnostic for radiation dose after LDR exposure. As part of this discussion, previously published clinical data on emesis after LDR total body irradiation (TBI) is statistically re-analyzed as an illustration of the complexity of the issue and confounding factors. This previously published data includes 107 patients who underwent TBI up to 10.5 Gy in a single fraction delivered over several hours at 0.02 to 0.04 Gy min. Estimates based on these data for the sensitivity of emesis as a screening diagnostic for the low dose rate radiation exposure range from 57.1% to 76.6%, and the estimates for specificity range from 87.5% to 99.4%. Though the original data contain multiple confounding factors, the evidence regarding sensitivity suggests that emesis appears to be quite poor as a medical screening diagnostic for LDR exposures.

  3. Insulin-Like Growth Factor 1 Mitigates Hematopoietic Toxicity After Lethal Total Body Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Dunhua; Deoliveira, Divino; Kang, Yubin; Choi, Seung S. [Department of Medicine, Duke University Medical Center, Durham, North Carolina (United States); Li, Zhiguo [Department of Biostatistics and Bioinformatics, Duke University Medical Center, Durham, North Carolina (United States); Chao, Nelson J. [Department of Medicine, Duke University Medical Center, Durham, North Carolina (United States); Department of Pathology, Duke University Medical Center, Durham, North Carolina (United States); Department of Immunology, Duke University Medical Center, Durham, North Carolina (United States); Duke Cancer Institute, Duke University Medical Center, Durham, North Carolina (United States); Chen, Benny J., E-mail: chen0032@mc.duke.edu [Duke Cancer Institute, Duke University Medical Center, Durham, North Carolina (United States); Department of Medicine, Duke University Medical Center, Durham, North Carolina (United States)

    2013-03-15

    Purpose: To investigate whether and how insulin-like growth factor 1 (IGF-1) mitigates hematopoietic toxicity after total body irradiation. Methods and Materials: BALB/c mice were irradiated with a lethal dose of radiation (7.5 Gy) and treated with IGF-1 at a dose of 100 μg/dose intravenously once a day for 5 consecutive days starting within 1 hour after exposure. Survival and hematopoietic recovery were monitored. The mechanisms by which IGF-1 promotes hematopoietic recovery were also studied by use of an in vitro culture system. Results: IGF-1 protected 8 of 20 mice (40%) from lethal irradiation, whereas only 2 of 20 mice (10%) in the saline control group survived for more than 100 days after irradiation. A single dose of IGF-1 (500 μg) was as effective as daily dosing for 5 days. Positive effects were noted even when the initiation of treatment was delayed as long as 6 hours after irradiation. In comparison with the saline control group, treatment with IGF-1 significantly accelerated the recovery of both platelets and red blood cells in peripheral blood, total cell numbers, hematopoietic stem cells, and progenitor cells in the bone marrow when measured at day 14 after irradiation. IGF-1 protected both hematopoietic stem cells and progenitor cells from radiation-induced apoptosis and cell death. In addition, IGF-1 was able to facilitate the proliferation and differentiation of nonirradiated and irradiated hematopoietic progenitor cells. Conclusions: IGF-1 mitigates radiation-induced hematopoietic toxicity through protecting hematopoietic stem cells and progenitor cells from apoptosis and enhancing proliferation and differentiation of the surviving hematopoietic progenitor cells.

  4. Insulin-Like Growth Factor 1 Mitigates Hematopoietic Toxicity After Lethal Total Body Irradiation

    International Nuclear Information System (INIS)

    Zhou, Dunhua; Deoliveira, Divino; Kang, Yubin; Choi, Seung S.; Li, Zhiguo; Chao, Nelson J.; Chen, Benny J.

    2013-01-01

    Purpose: To investigate whether and how insulin-like growth factor 1 (IGF-1) mitigates hematopoietic toxicity after total body irradiation. Methods and Materials: BALB/c mice were irradiated with a lethal dose of radiation (7.5 Gy) and treated with IGF-1 at a dose of 100 μg/dose intravenously once a day for 5 consecutive days starting within 1 hour after exposure. Survival and hematopoietic recovery were monitored. The mechanisms by which IGF-1 promotes hematopoietic recovery were also studied by use of an in vitro culture system. Results: IGF-1 protected 8 of 20 mice (40%) from lethal irradiation, whereas only 2 of 20 mice (10%) in the saline control group survived for more than 100 days after irradiation. A single dose of IGF-1 (500 μg) was as effective as daily dosing for 5 days. Positive effects were noted even when the initiation of treatment was delayed as long as 6 hours after irradiation. In comparison with the saline control group, treatment with IGF-1 significantly accelerated the recovery of both platelets and red blood cells in peripheral blood, total cell numbers, hematopoietic stem cells, and progenitor cells in the bone marrow when measured at day 14 after irradiation. IGF-1 protected both hematopoietic stem cells and progenitor cells from radiation-induced apoptosis and cell death. In addition, IGF-1 was able to facilitate the proliferation and differentiation of nonirradiated and irradiated hematopoietic progenitor cells. Conclusions: IGF-1 mitigates radiation-induced hematopoietic toxicity through protecting hematopoietic stem cells and progenitor cells from apoptosis and enhancing proliferation and differentiation of the surviving hematopoietic progenitor cells

  5. The relationship of total body composition with bone mineral density in postmenopausal women with type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Vadim Valer'evich Klimontov

    2015-03-01

    Full Text Available Aim. To determine the relationship between bone mineral density (BMD and total body composition in postmenopausal women with type 2 diabetes. Materials and Methods. The study included 78 women, from 50 to 70 years of age (median 63 years. Twenty women had normal body mass index (BMI, 29 ones were overweight and 29 had obesity. The body composition and BMD was studied by dual-energy X-ray absorptiometry. Results. Women with normal BMD had higher BMI, total and truncal fat mass, as well lean mass as compared to women with osteoporosis and osteopenia (all p

  6. Cross-sex hormone therapy in transgender persons affects total body weight, body fat and lean body mass: a meta-analysis.

    Science.gov (United States)

    Klaver, M; Dekker, M J H J; de Mutsert, R; Twisk, J W R; den Heijer, M

    2017-06-01

    Weight gain and body fat increase the risk of cardiometabolic disease. Cross-sex hormone therapy in transgender persons leads to changes in body weight and body composition, but it is unclear to what extent. We performed a meta-analysis to investigate the changes in body weight, body fat and lean body mass during cross-sex hormone therapy in transgender persons. We searched the PubMed database for eligible studies until November 2015. Ten studies reporting changes in body weight, body fat or lean mass in hormone naive transgender persons were included, examining 171 male-to-female and 354 female-to-male transgender people. Pooled effect estimates in the male-to-female group were +1.8 kg (95% CI: 0.2;3.4) for body weight, +3.0 kg (2.0;3.9) for body fat and -2.4 kg (-2.8; -2.1) for lean body mass. In the female-to-male group, body weight changed with +1.7 kg (0.7;2.7), body fat with -2.6 kg (-3.9; -1.4) and lean body mass with +3.9 kg (3.2;4.5). Cross-sex hormone therapy increases body weight in both sexes. In the male-to-female group, a gain in body fat and a decline in lean body mass are observed, while the opposite effects are seen in the female-to-male group. Possibly, these changes increase the risk of cardiometabolic disease in the male-to-female group. © 2016 Blackwell Verlag GmbH.

  7. Water turnover rate and total body water affected by different physiological factors under Egyptian environmental conditions

    International Nuclear Information System (INIS)

    Kamal, T.H.

    1982-01-01

    The tritiated water dilution technique was used to determine the total body water (TBW) and water turnover rate (WTR), which is assumed to be similar to water intake, in water buffalo, Red Danish cattle, fat-tailed Osemi sheep and crossed Nubian-Bedouin goats and camels (Camelus dromedarius). There was a significant (P < 0.05) effect of species on TBW and WTR. The combined data of buffalo, cattle and sheep revealed a significant (P < 0.05) effect of pregnancy on TBW, but not on WTR. The combined data of buffalo and cattle showed a significantly lower TBW (P < 0.01) and a higher WTR (P < 0.05) in lactating animals than in heifers. In buffalo WTR was on average 81% higher in summer grazing (SG) than in spring. It was also 118 and 20% higher in summer non-grazing (SNG), than in either spring or SG, respectively. The differences between treatments in heifers, pregnant and lactating, were significant (P<0.01), except between spring and SG in heifers. The TBW was on average 12% higher in SG than in spring. It was also 18 and 5% higher in SNG than in either spring or SG, respectively. The differences between treatments in heifers, pregnant and lactating, were significant, except between SG and SNG in heifers and lactating cows and between spring and SG in lactating cows. (author)

  8. Therapeutic effect of bone marrow transplantation plue previous blood transfusion on rats with total body irradiation

    International Nuclear Information System (INIS)

    Yan Yongtang; Ran Xinze; Wei Shuqing

    1988-01-01

    Therapeutic effect of bone marrow transplantation (BMT) and blood transfusion on different groups of rats subjected to various doses of total body irradiation (TBI) was studied. In the control group, 80 rats that received TBI of 8,9,10,11 and 12 Gy died between 3∼14 days. In the second group, 67 rats that received the same doses of irradiation were treated with BMT. Except that 8 rats died from lung hemorrhages at 4∼6 days after TBI. 85% of these animals (500/59) showed hemopoietic engraftment. The survival rates of 8, 9, 10, 11 and 12 Gy subgroups at 90 days after BMT were 90%, 56%, 56%, 25% and 0% respectively. In the third group, 82 rats receive TBI and blood transfusion prior to BMT. Except that 8 rats subjected to 11∼12 Gy irradiation died from lung hemorrhage at 4∼6 days after BMT, 97% of these animals (72/74) showed hemopoietic engraftment. The 90-day survival rates of 8, 9, 10, 11 and 12 Gy subgroups were 93%, 80%, 80%, 60% and 6% respectively. The 90-day survival rate of 50 rats subjected to 9∼11 Gy TBI and treated with blood transfusion and BMT, was 72%, while that 47 rats treated simply with BMT was only 42%. These results showed clearly that previous blood transfusion could increase the rate of hemopoietic engraftment, reduce the incidence if rejection, and raise the survival rate

  9. A comparative study of total body irradiation as a method of inducing granulocyte depletion in mice

    International Nuclear Information System (INIS)

    Bogman, M.J.J.T.; Cornelissen, I.M.H.A.; Berden, J.H.M.; Jong, J. de; Koene, R.A.P.

    1984-01-01

    Since conventional methods of inducing depletion of polymorphonuclear granulocytes (PMNs) in mice, such as treatment with cytostatic drugs and anti-PMN sera, proved to be insufficient to induce a stable PMN depletion for several days, and were accompanied by considerable toxic side effects, we induced neutrophil depletion in mice by total body irradiation (TBI) in a single dose of 6.0 Gy (600 rads.) at a dose rate of 0.20 Gy/min. This treatment reduced the number of PMNs in the peripheral circulation to values below 150/μl from day 3-10 after irradiation. The number of lymphocytes fell simultaneously. Platelet counts remained above 60% of normal values during the first 7 days after irradiation. Complement levels were not significantly affected by TBI. The results show that TBI of 6.0 Gy induces pronounced and stable PMN depletion in mice for at least 7 days. Furthermore, under an aseptic regimen the mice can be kept in good condition and losses are less than 5%. (Auth.)

  10. Induction of systemic bone changes by preconditioning total body irradiation for bone marrow transplantation

    International Nuclear Information System (INIS)

    Miyazaki, Osamu; Okamoto, Reiko; Masaki, Hidekazu; Nishimura, Gen; Kumagai, Masaaki; Shioda, Yoko; Nozawa, Kumiko; Kitoh, Hiroshi

    2009-01-01

    Preconditioning total body irradiation (TBI) prior to bone marrow transplantation (BMT) has been believed to be a safe procedure that does not cause late morbidity; yet, a recent report raises the suspicion that TBI-induced chondroosseous abnormalities do occur. To evaluate the radiological manifestations of TBI-induced skeletal alterations and their orthopaedic morbidity. Subjects included 11 children with TBI-induced skeletal changes, including 9 in our hospital and 2 in other hospitals. The former were selected from 53 children who had undergone TBI with BMT. Radiographic examinations (n=11), MRI (n=3), CT (n=2), and medical records in the 11 children were retrospectively reviewed. The skeletal alterations included abnormal epiphyseal ossification and metaphyseal fraying (8/11), longitudinal metaphyseal striations (8/11), irregular metaphyseal sclerosis (6/11), osteochondromas (4/11), slipped capital femoral epiphysis (2/10), genu valgum (3/10), and platyspondyly (2/3). MRI demonstrated immature primary spongiosa in the metaphysis. Of the 11 children, 9 had clinical symptoms. TBI can induce polyostotic and/or generalized bone changes, mainly affecting the epiphyseal/metaphyseal regions and occasionally the spine. The epi-/metaphyseal abnormalities represent impaired chondrogenesis in the epiphysis and growth plate and abnormal remodelling in the metaphysis. Generalized spine changes may lead to misdiagnosis of a skeletal dysplasia. (orig.)

  11. Optimized total body irradiation for induction of renal allograft tolerance through mixed chimerism in cynomolgus monkeys

    International Nuclear Information System (INIS)

    Kimikawa, Masaaki; Kawai, Tatsuo; Ota, Kazuo

    1996-01-01

    We previously demonstrated that a nonmyeloablative preparative regimen can induce mixed chimerism and renal allograft tolerance between MHC-disparate non-human primates. The basic regimen includes anti-thymocyte globulin (ATG), total body irradiation (TBI, 300 cGy), thymic irradiation (TI, 700 cGy), splenectomy, donor bone marrow (DBM) infusion, and posttransplant cyclosporine therapy (CYA, discontinued after 4 weeks). To evaluate the importance and to minimize the toxicity of irradiation, kidney allografts were transplanted with various manipulations of the irradiation protocol. Monkeys treated with the basic protocol without TBI and TI did not develop chimerism or long-term allograft survival. In monkeys treated with the full protocol, all six monkeys treated with two fractionated dose of 150 cGy developed chimerism and five monkeys appeared tolerant. In contrast, only two of the four monkeys treated with fractionated doses of 125 cGy developed chimerism and only one monkey survived long term. The degree of lymphocyte depletion in all recipients was proportional to the TBI dose. The fractionated TBI regimen of 150 cGy appears to be the most consistently effective regimen for establishing donor bone marrow cell engraftment and allograft tolerance. (author)

  12. Time- and dose-dependent effects of total-body ionizing radiation on muscle stem cells

    Science.gov (United States)

    Masuda, Shinya; Hisamatsu, Tsubasa; Seko, Daiki; Urata, Yoshishige; Goto, Shinji; Li, Tao-Sheng; Ono, Yusuke

    2015-01-01

    Exposure to high levels of genotoxic stress, such as high-dose ionizing radiation, increases both cancer and noncancer risks. However, it remains debatable whether low-dose ionizing radiation reduces cellular function, or rather induces hormetic health benefits. Here, we investigated the effects of total-body γ-ray radiation on muscle stem cells, called satellite cells. Adult C57BL/6 mice were exposed to γ-radiation at low- to high-dose rates (low, 2 or 10 mGy/day; moderate, 50 mGy/day; high, 250 mGy/day) for 30 days. No hormetic responses in proliferation, differentiation, or self-renewal of satellite cells were observed in low-dose radiation-exposed mice at the acute phase. However, at the chronic phase, population expansion of satellite cell-derived progeny was slightly decreased in mice exposed to low-dose radiation. Taken together, low-dose ionizing irradiation may suppress satellite cell function, rather than induce hormetic health benefits, in skeletal muscle in adult mice. PMID:25869487

  13. Physically-based biodosimetry using in vivo EPR of teeth in patients undergoing total body irradiation

    Science.gov (United States)

    Williams, Benjamin B.; Dong, Ruhong; Nicolalde, Roberto J.; Matthews, Thomas P.; Gladstone, David J.; Demidenko, Eugene; Zaki, Bassem I.; Salikhov, Ildar K.; Lesniewski, Piotr N.; Swartz, Harold M.

    2014-01-01

    Purpose The ability to estimate individual exposures to radiation following a large attack or incident has been identified as a necessity for rational and effective emergency medical response. In vivo electron paramagnetic resonance (EPR) spectroscopy of tooth enamel has been developed to meet this need. Materials and methods A novel transportable EPR spectrometer, developed to facilitate tooth dosimetry in an emergency response setting, was used to measure upper incisors in a model system, in unirradiated subjects, and in patients who had received total body doses of 2 Gy. Results A linear dose response was observed in the model system. A statistically significant increase in the intensity of the radiation-induced EPR signal was observed in irradiated versus unirradiated subjects, with an estimated standard error of dose prediction of 0.9 + 0.3 Gy. Conclusions These results demonstrate the current ability of in vivo EPR tooth dosimetry to distinguish between subjects who have not been irradiated and those who have received exposures that place them at risk for acute radiation syndrome. Procedural and technical developments to further increase the precision of dose estimation and ensure reliable operation in the emergency setting are underway. With these developments EPR tooth dosimetry is likely to be a valuable resource for triage following potential radiation exposure of a large population. PMID:21696339

  14. Prospective evaluation of delayed central nervous system (CNS) toxicity of hyperfractionated total body irradiation (TBI)

    International Nuclear Information System (INIS)

    Wenz, Frederik; Steinvorth, Sarah; Lohr, Frank; Fruehauf, Stefan; Wildermuth, Susanne; Kampen, Michael van; Wannenmacher, Michael

    2000-01-01

    Purpose: Prospective evaluation of chronic radiation effects on the healthy adult brain using neuropsychological testing of intelligence, attention, and memory. Methods and Materials: 58 patients (43 ± 10 yr) undergoing hyperfractionated total body irradiation (TBI) (TBI, 14.4 Gy, 12 x 1.2 Gy in 4 days) before bone marrow or peripheral blood stem cell transplantation were prospectively included. Twenty-one recurrence-free long-term survivors were re-examined 6-36 months (median 27 months) after completion of TBI. Neuropsychological testing included assessment of general intelligence, attention, and memory using normative, standardized psychometric tests. Mood status was controlled, as well. Test results are given as IQ scores (population mean 100) or percentiles for attention and memory (population mean 50). Results: The 21 patients showed normal baseline test results of IQ (101 ± 13) and attention (53 ± 28), with memory test scores below average (35 ± 21). Test results of IQ (98 ± 17), attention (58 ± 27), and memory (43 ± 28) showed no signs of clinically measurable radiation damage to higher CNS (central nervous system) functions during the follow-up. The mood status was improved. Conclusion: The investigation of CNS toxicity after hyperfractionated TBI showed no deterioration of test results in adult recurrence-free patients with tumor-free CNS. The median follow-up of 27 months will be extended.

  15. Factors associated with pulmonary toxicity after myeloablative conditioning using fractionated total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Hwa Kyung; Yoon, Hong In; Cho, Jae Ho [Yonsei Cancer Center, Yonsei University College of Medicine, Seoul (Korea, Republic of); and others

    2017-09-15

    Pulmonary toxicities, including infectious pneumonia (IP) and idiopathic pneumonia syndrome (IPS), are serious side effects of total body irradiation (TBI) used for myeloablative conditioning. This study aimed to evaluate clinical factors associated with IP and IPS following TBI. Fifty-eight patients with hematologic malignancies who underwent TBI before allogeneic hematopoietic stem cell transplantation between 2005 and 2014 were reviewed. Most patients (91%) received 12 Gy in 1.5 Gy fractions twice a day. Pulmonary toxicities were diagnosed based on either radiographic evidence or reduced pulmonary function, and were subdivided into IP and IPS based on the presence or absence of concurrent infection. Pulmonary toxicities developed in 36 patients (62%); 16 (28%) had IP and 20 (34%) had IPS. IP was significantly associated with increased treatment-related mortality (p = 0.028) and decreased survival (p = 0.039). Multivariate analysis revealed that the risk of developing IPS was significantly higher in patients who received stem cells from a matched unrelated donor than from a matched sibling donor (p = 0.021; hazard ratio [HR] = 12.67; 95% confidence interval [CI], 1.46–110.30). Combining other conditioning agents with cyclophosphamide produced a higher tendency to develop IP (p = 0.064; HR = 6.19; 95% CI, 0.90–42.56). IP and IPS involve different risk factors and distinct pathogeneses that should be considered when planning treatments before and after TBI.

  16. Efficacy of granisetron in the prevention of GIT problems in patients undergoing total body irradiation

    International Nuclear Information System (INIS)

    Feuvret, L.; Jammet, P.; Campana, F.; Cosset, J.M.; Fourquet, A.

    1994-01-01

    From december 1991 to september 1992, 20 patients due to receive total body irradiation (TBI) prior to allogeneic or autologous bone marrow transplantation were given granisetron (Kytril) in order to prevent intestinal (nausea and vomiting) early intolerance, TBI regimen was delivered on a fractional basis of six fractions, over 3 days. Twelve grays were delivered with a lung protection decreasing the pulmonary dose to 9 Gy Granisetron (3 mg) was administered by a 5-min intravenous infusion, 1 h before TBI. Up to two further infusions were given if nausea or vomiting occurred. The pretreatment perfusion was sufficient to prevent nausea and vomiting in 10/20 patients, one additional post-treatment perfusion was necessary in 7/20 patients, and two in 1/20 patients. In 2/20 cases, nausea and vomiting persisted in spite of three perfusions. Excellent or good efficacy was noted in 15/20 patients and a minor (or no) efficacy in five. Granisetron appears to be superior to the conventional anti emetic schemes to prevent nausea and vomiting in patients receiving TBI for bone marrow transplantation. 15 Refs

  17. Anti-tumor effect of total body irradiation of low doses on WHT/Ht mice

    International Nuclear Information System (INIS)

    Miyamoto, Miyako; Sakamoto, Kiyohiko

    1987-01-01

    The effect of low dose (0.05 - 1.0 Gy) of total body irradiation (TBI) on non-tumor bearing and tumor bearing mice were investigated. Mice received TBI of 0.1 Gy during 6 - 12 hours before tumor cell inoculation demonstrated to need larger number of tumor cells (approximately 2.5 times) for 50 per cent tumor incidence, compared to recipient mice not to receive TBI. On the other hand, in tumor bearing mice given 0.1 Gy of TBI only tumor cell killing effect was not detected, however enhancement of tumor cell killing effect and prolonged growth delay were observed when tumor bearing mice were treated with 0.1 Gy of TBI in combined with local irradiation on tumors, especially cell killing effect was remarkable in dose range over 6 Gy of local exposure. The mechanism of the effect of 0.1 Gy TBI is considered to be host mediated reactions from the other our experimental results. (author)

  18. In vivo induction of apoptosis in human lymphocytes by therapeutic fractionated total body irradiation

    International Nuclear Information System (INIS)

    Delic, J.; Magdelenat, H.; Barbaroux, C.; Chaillet, M.-P.; Dubray, B.; Fourquet, A.; Cosset, J.-M.; Gluckman, E.; Girinsky, T.

    1995-01-01

    Ionizing radiations have been reported as an in vitro apoptosis initiating stimulus in human lymphocytes. As the cytotoxicity of ionizing radiations and chemotherapeutic agents appears to be dependent on the efficacy of cell death induction, the manipulation of apoptosis initiation might be used as a means to suppress some pathological process. In the present study the in vivo induction of γ-ray mediated programmed cell death in humans is reported. The in vivo induction of apoptosis in peripheral blood lymphocytes (PBL) by ionizing radiations was investigated in 33 patients after each of two sessions (2 Gy and 4 Gy) of fractionated total body irradiation (FTBI) as part of their conditioning regimen before bone marrow transplantation. PBL committed to apoptosis were scored before irradiation (S1), 4 h (S2) and 24 h after 2 Gy (S3, 14-17 h after the second 2 Gy fraction). Nuclear morphology and chromatin-DNA were analysed by fluorescence microscopy immediately after blood sample withdrawal (I) and after 24 h in cell culture medium (II). (author)

  19. ACPSEM ROSG TBI working group recommendations for quality assurance in total body irradiation

    International Nuclear Information System (INIS)

    Nelligan, Raelene; Bailey, Michael; Tran, Thu; Baldwin, Zoe

    2015-01-01

    The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) radiation oncology specialty group (ROSG) formed a series of working groups in 2011 to develop recommendations for guidance of radiation oncology medical physics practice within the Australasian setting. These recommendations are intended to provide guidance for safe work practices and a suitable level of quality control without detailed work instructions. It is the responsibility of the medical physicist to ensure that locally available equipment and procedures are sufficiently sensitive to establish compliance to these recommendations. The recommendations are endorsed by the ROSG, and have been subject to independent expert reviews. For the Australian audience, these recommendations should be read in conjunction with the tripartite radiation oncology practice standards [1, 2]. This publication presents the recommendations of the ACPSEM total body irradiation working group (TBIWG) and has been developed in alignment with other international associations. However, these recommendations should be read in conjunction with relevant national, state or territory legislation and local requirements, which take precedence over the ACPSEM recommendations. It is hoped that the users of this and other ACPSEM recommendations will contribute to the development of future versions through the ROSG of the ACPSEM. This document serves as a guideline for calibration and quality assurance of equipment used for TBI in Australasia.

  20. ACPSEM ROSG TBE working group recommendations for quality assurance in total body electron irradiation

    International Nuclear Information System (INIS)

    Nelligan, Raelene; Baldwin, Zoe; Ostwald, Trish; Tran, Thi; Bailey, Michael

    2015-01-01

    The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups in 2011 to develop recommendations for guidance of radiation oncology medical physics practice within the Australasian setting. These recommendations are intended to provide guidance for safe work practices and a suitable level of quality control without detailed work instructions. It is the responsibility of the medical physicist to ensure that locally available equipment and procedures are sufficiently sensitive to establish compliance to these recommendations. The recommendations are endorsed by the ROSG, and have been subject to independent expert reviews. For the Australian readers, these recommendations should be read in conjunction with the Tripartite Radiation Oncology Reform Implementation Committee Quality Working Group: Radiation Oncology Practice Standards (2011), and Radiation Oncology Practice Standards Supplementary Guide (2011). This publication presents the recommendations of the ACPSEM ROSG Total Body Electron Irradiation Working Group and has been developed in alignment with other international associations. However, these recommendations should be read in conjunction with relevant national, state or territory legislation and local requirements, which take precedence over the ACPSEM recommendations. It is hoped that the users of this and other ACPSEM recommendations will contribute to the development of future versions through the Radiation Oncology Specialty Group of the ACPSEM. This document serves as a guideline for calibration and quality assurance of equipment used for TBE in Australasia.

  1. Medium modified two-body scattering amplitude from proton-nucleus total cross-sections

    Science.gov (United States)

    Tripathi, R. K.; Wilson, J. W.; Cucinotta, F. A.

    2001-01-01

    Recently (R.K. Tripathi, J.W. Wilson, F.A. Cucinotta, Nucl. Instr. and Meth. B 145 (1998) 277; R.K. Tripathi, F.A. Cucinotta, J.W. Wilson, NASA-TP-1998-208438), we have extracted nucleon-nucleon (N-N) cross-sections in the medium directly from experiment. The in-medium N-N cross-sections form the basic ingredients of several heavy-ion scattering approaches including the coupled-channel approach developed at the NASA Langley Research Center. Here, we investigate the ratio of real to imaginary part of the two-body scattering amplitude in the medium. These ratios are used in combination with the in-medium N-N cross-sections to calculate total proton-nucleus cross-sections. The agreement is excellent with the available experimental data. These cross-sections are needed for the radiation risk assessment of space missions. c2001 Elsevier Science B.V. All rights reserved.

  2. The biological effects of high dose total body irradiation in beagle dogs

    International Nuclear Information System (INIS)

    Luo Qingliang; Liu Xiaolan; Hao Jing; Xiong Guolin; Dong Bo; Zhao Zhenhu; Xia Zhengbiao; Qiu Liling; Mao Bingzhi

    2002-01-01

    Objective: To evaluate the biological effects of Beagle dogs irradiated by γ-rays at different doses. Methods: All Beagle dogs were divided into six groups and were subjected respectively to total-body irradiation (TBI) with a single dose of 6.5, 5.5, 5.0, 4.5, 3, 5 and 2.5 Gy γ-rays delivered by 60 Co sources at 7.224 x 10 -2 C/kg per minute. The general condition, blood cell counts and bone marrow cell CFC assays were observed. Results: Vomiting occurred at 0.5 to 2 hours after TBI in all groups. In 6.5 Gy group 3/5 dogs had blood-watery stool and 1/5 in 5.5 Gy group had watery stool. Diarrhea occurred in all other animals. Only one dog in 2.5 Gy group survived, all of others died. in order of decreasing irradiation dosage, the average survival time was 5.0, 8.0, 9.3, 9.5, 10.5 and 14.1 days, respectively. Conclusions: According to the clinical symptoms, leukocyte count and survival time of the dogs, the irradiation dose which will induce very severe hematopoietic radiation syndrome in Beagle dogs is 4.5 to 5.0 Gy

  3. Total body irradiation therapy for thymectomized myasthenic patients and immunological evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Yamanaka, Nobukazu; Tanaka, Masayuki; Kurihara, Teruyuki (Miyazaki Medical College (Japan))

    1983-06-01

    Three patients with intractable myasthenia gravis (MG) were treated with total body irradiation (TBI). All the three patients had been unstable after extended thymectomy and poorly responding to prednisolone therapy. Radiation therapy consisted of 10 doses of 10 rads/day given over five weeks. After the radiation therapy the three patients improved clinically, and an objective parameter, area of M-waves also improved. No significant side effects were noted. TBI therapy can be considered as a safe method to induce selective reduction of circulating lymphocytes. This was indeed achieved, as evidenced by a drop of the lymphocyte counts to the levels of 20-40 % of the pretreatment level. The effects were persistent over twelve weeks. Early radiosensitivity of B lymphocytes were recognized. The levels of T..gamma.. cells were low before TBI therapy, increasing gradually during TBI therapy and returned to normal range after twelve weeks. Serum anti-AChR antibody titers decreased in all the cases, but it was impossible to determine whether the decrement was due to the therapy or natural course after thymectomy. Two of our three cases had a significant percentage decrement of the titers after TBI therapy. We suggest that TBI therapy is a safe method of immunosupperssive treatment for the myasthenic patients after thymectomy.

  4. Total body irradiation therapy for thymectomized myasthenic patients and immunological evaluations

    International Nuclear Information System (INIS)

    Yamanaka, Nobukazu; Tanaka, Masayuki; Kurihara, Teruyuki

    1983-01-01

    Three patients with intractable myasthenia gravis (MG) were treated with total body irradiation (TBI). All the three patients had been unstable after extended thymectomy and poorly responding to prednisolone therapy. Radiation therapy consisted of 10 doses of 10 rads/day given over five weeks. After the radiation therapy the three patients improved clinically, and an objective parameter, area of M-waves also improved. No significant side effects were noted. TBI therapy can be considered as a safe method to induce selective reduction of circulating lymphocytes. This was indeed achieved, as evidenced by a drop of the lymphocyte counts to the levels of 20-40 % of the pretreatment level. The effects were persistent over twelve weeks. Early radiosensitivity of B lymphocytes were recognized. The levels of Tγ cells were low before TBI therapy, increasing gradually during TBI therapy and returned to normal range after twelve weeks. Serum anti-AChR antibody titers decreased in all the cases, but it was impossible to determine whether the decrement was due to the therapy or natural course after thymectomy. Tow of our three cases had a significant percentage decrement of the titers after TBI therapy. We suggest that TBI therapy is a safe method of immunosupperssive treatment for the myasthenic patients after thymectomy. (author)

  5. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    Science.gov (United States)

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  6. The enhanced total body wrap--the new frontier in dressing care for burns.

    Science.gov (United States)

    Low, O-Wern; Chong, Si Jack; Tan, Bien-Keem

    2013-11-01

    The management of extensive burns with their associated high fluid exudate following burn excision and skin grafting has always posed a challenge in burn wound care. The ideal dressing should protect the wound from physical damage and micro-organisms; be comfortable and durable; allow high humidity at the wound; and be able to allow maximal activity for wound healing without retarding or inhibiting any stage of the process. The dressing technique described in this paper fulfils all the criteria above and at the same time provides an efficient channel to effectively clear the excessive exudate produced while keeping the wounds moist. Advantages conferred include accurate charting of wound exudate; reduced frequency of dressing changes; lower infection rates through prevention of strike-through; and securing and improving the viability of skin grafts. An enhancement to a technique previously described by us through the use of long thin strips of VAC sponges to transmit negative pressure, the enhanced Total Body Wrap aims to provide ideal conditions to promote healing in burns. Using negative pressure wound therapy (NPWT), this technique is simple and straightforward enough to be applied in majority of tertiary centres around the world. Copyright © 2013. Published by Elsevier Ltd.

  7. Total Body Irradiation for Allogeneic Bone Marrow Transplantation in Chronic Myelogenous Leukemia

    International Nuclear Information System (INIS)

    Chung, Su Mi; Choi, Ihl Bohng; Kang, Ki Mun; Kim, In Ah; Shinn, Kyung Sub; Kim, Choon Choo; Kim, Dong Jip

    1994-01-01

    Between July 1987 and December 1992, we treated 22 patients with chromic myelogenous leukemia; 14 in the chronic phase and 8 with more advanced disease. All were received with allogeneic bone marrow transplantation from HLA-identical sibling donors after a total body irradiation (TBI) cyclophosphamide conditioning regimen. Patients were non-randomly assigned to either 1200 cGy/6 fractions/3 days (6 patients) or 1320 cGy/8 fractions/4 days (16 patients) by dose of TBI. Of the 22 patients, 8 were prepared with cyclophosphamide alone, 14 were conditioned with additional adriamycin or daunorubicin. To prevent graft versus host disease, cyclosporine was given either alone or in conjunction with methotrexate. The actuarial survival and leukemic-free survival at four years were 58.5% and 41.2%, respectively, and the relapse rate was 36% among 22 patients. There was a statistically significant difference in survival between the patients in chronic phase and more advanced phase (76% vs 33%, p=0.05). The relapse rate of patients receiving splenectomy was higher than that of patients receiving splenic irradiation (50% vs 0%, p=0.04). We conclude that the probability of cure is highest if transplantation is performed while the patient remains in the chronic phase

  8. Marrow transplantation for leukemia following fractionated total body irradiation. A comparative trial of methotrexate and cyclosporine

    International Nuclear Information System (INIS)

    Irle, C.; Deeg, H.J.; Buckner, C.D.; Swedish Hospital Medical Center, Seattle, WA; Veterans Administration Hospital, Seattle, WA; Washington Univ., Seattle

    1985-01-01

    Fifty-six patients, 30-47 yr of age, with leukemia in relapse received allogeneic marrow transplants from HLA-identical siblings. All patients were treated with cyclophosphamide (120 mg/kg) and 7 daily fractions of 2.25 Gy of total body irradiation (TBI) for seven consecutive days. Nine patients (16%) are currently alive, free of disease, 324-845 days from transplantation. Actuarial relapse and survival rates at 2 yr were 56% and 9.5% respectively. These data were not remarkably different from those in previous studies using 10 Gy of TBI administered as a single dose. Thirty patients were randomized to receive methotrexate (MTX) and 26 to receive cyclosporine (CSP) as postgrafting prophylaxis for acute graft-versus-host disease (GVHD). Probability of developing significant acute GVHD by day 100 post-transplant was 71% for patients in the MTX group and 45% for patients in the CSP group (p<0.05). Probability of relapse was 37% for patients in the MTX group and 70% for patients in the CSP group (p<0.05). Transplant-related deaths were more frequent in the MTX group and leukemic deaths more frequent in the CSP group although this may have been related to an uneven distribution of high-risk patients. Long term disease-free survival was comparable. (author)

  9. The effect of low-dose total body irradiation on tumor control

    International Nuclear Information System (INIS)

    Sakamoto, Kiyohiko; Miyamoto, Miyako; Watabe, Nobuyuki.

    1987-01-01

    Total body irradiation (TBI) is considered to bring about an immunosuppressive effect on an organism, on the basis of data obtained from sublethal doses of TBI. However, there are no data on how low-dose TBI affects an organism. Over the last five years, we have been studying the effects of low-dose TBI on normal or tumor-bearing mice and the immunological background of these effects. In experimental studies, an increase in the TD50 value (the number of cells required for a tumor incidence of 50 %) in mice exposed to 10 rad was recognized and showed a remarkable increase at 6 hours to 15 hours after irradiation. TBI of 10 rad also showed an enhancement effect on tumor cell killing when given 12 hours before local tumor irradiation. In order to clarify the mechanism of this kind of effect, some immunological studies were performed using several immunological procedures, and the results suggested that 10 rad of TBI caused increasing tumor immunity in irradiated mice. Clinical trials in some patients with advanced tumors are now being undertaken on the basis of these experimental data, and the effect of TBI on tumor control appears promising, although it is too early to draw conclusions. (author)

  10. Optimized total body irradiation for induction of renal allograft tolerance through mixed chimerism in cynomolgus monkeys

    Energy Technology Data Exchange (ETDEWEB)

    Kimikawa, Masaaki; Kawai, Tatsuo; Ota, Kazuo [Tokyo Women`s Medical Coll. (Japan)

    1996-12-01

    We previously demonstrated that a nonmyeloablative preparative regimen can induce mixed chimerism and renal allograft tolerance between MHC-disparate non-human primates. The basic regimen includes anti-thymocyte globulin (ATG), total body irradiation (TBI, 300 cGy), thymic irradiation (TI, 700 cGy), splenectomy, donor bone marrow (DBM) infusion, and posttransplant cyclosporine therapy (CYA, discontinued after 4 weeks). To evaluate the importance and to minimize the toxicity of irradiation, kidney allografts were transplanted with various manipulations of the irradiation protocol. Monkeys treated with the basic protocol without TBI and TI did not develop chimerism or long-term allograft survival. In monkeys treated with the full protocol, all six monkeys treated with two fractionated dose of 150 cGy developed chimerism and five monkeys appeared tolerant. In contrast, only two of the four monkeys treated with fractionated doses of 125 cGy developed chimerism and only one monkey survived long term. The degree of lymphocyte depletion in all recipients was proportional to the TBI dose. The fractionated TBI regimen of 150 cGy appears to be the most consistently effective regimen for establishing donor bone marrow cell engraftment and allograft tolerance. (author)

  11. Total Body Irradiation for Allogeneic Bone Marrow Transplantation in Chronic Myelogenous Leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Su Mi; Choi, Ihl Bohng; Kang, Ki Mun; Kim, In Ah; Shinn, Kyung Sub; Kim, Choon Choo; Kim, Dong Jip [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1994-06-15

    Between July 1987 and December 1992, we treated 22 patients with chromic myelogenous leukemia; 14 in the chronic phase and 8 with more advanced disease. All were received with allogeneic bone marrow transplantation from HLA-identical sibling donors after a total body irradiation (TBI) cyclophosphamide conditioning regimen. Patients were non-randomly assigned to either 1200 cGy/6 fractions/3 days (6 patients) or 1320 cGy/8 fractions/4 days (16 patients) by dose of TBI. Of the 22 patients, 8 were prepared with cyclophosphamide alone, 14 were conditioned with additional adriamycin or daunorubicin. To prevent graft versus host disease, cyclosporine was given either alone or in conjunction with methotrexate. The actuarial survival and leukemic-free survival at four years were 58.5% and 41.2%, respectively, and the relapse rate was 36% among 22 patients. There was a statistically significant difference in survival between the patients in chronic phase and more advanced phase (76% vs 33%, p=0.05). The relapse rate of patients receiving splenectomy was higher than that of patients receiving splenic irradiation (50% vs 0%, p=0.04). We conclude that the probability of cure is highest if transplantation is performed while the patient remains in the chronic phase.

  12. Body mass and weight thresholds for increased prosthetic joint infection rates after primary total joint arthroplasty.

    Science.gov (United States)

    Lübbeke, Anne; Zingg, Matthieu; Vu, Diemlan; Miozzari, Hermes H; Christofilopoulos, Panayiotis; Uçkay, Ilker; Harbarth, Stephan; Hoffmeyer, Pierre

    2016-01-01

    Obesity increases the risk of deep infection after total joint arthroplasty (TJA). Our objective was to determine whether there may be body mass index (BMI) and weight thresholds indicating a higher prosthetic joint infection rate. We included all 9,061 primary hip and knee arthroplasties (mean age 70 years, 61% women) performed between March 1996 and December 2013 where the patient had received intravenous cefuroxime (1.5 g) perioperatively. The main exposures of interest were BMI (5 categories: prosthetic joint infection. The mean follow-up time was 6.5 years (0.5-18 years). 111 prosthetic joint infections were observed: 68 postoperative, 16 hematogenous, and 27 of undetermined cause. Incidence rates were similar in the first 3 BMI categories (infection from the early postoperative period onward (adjusted HR = 2.1, 95% CI: 1.3-3.6). BMI ≥ 35 or weight ≥ 100 kg may serve as a cutoff for higher perioperative dosage of antibiotics.

  13. Interobserver Reliability of the Total Body Score System for Quantifying Human Decomposition.

    Science.gov (United States)

    Dabbs, Gretchen R; Connor, Melissa; Bytheway, Joan A

    2016-03-01

    Several authors have tested the accuracy of the Total Body Score (TBS) method for quantifying decomposition, but none have examined the reliability of the method as a scoring system by testing interobserver error rates. Sixteen participants used the TBS system to score 59 observation packets including photographs and written descriptions of 13 human cadavers in different stages of decomposition (postmortem interval: 2-186 days). Data analysis used a two-way random model intraclass correlation in SPSS (v. 17.0). The TBS method showed "almost perfect" agreement between observers, with average absolute correlation coefficients of 0.990 and average consistency correlation coefficients of 0.991. While the TBS method may have sources of error, scoring reliability is not one of them. Individual component scores were examined, and the influences of education and experience levels were investigated. Overall, the trunk component scores were the least concordant. Suggestions are made to improve the reliability of the TBS method. © 2016 American Academy of Forensic Sciences.

  14. Immunoglobulin levels in dogs after total-body irradiation and bone marrow transplantation

    International Nuclear Information System (INIS)

    Vriesendorp, H.M.; Halliwell, R.E.; Johnson, P.M.; Fey, T.A.; McDonough, C.M.

    1985-01-01

    The influence of total-body irradiation (TBI) and autologous or allogeneic bone marrow transplantation on serum immunoglobulin subclasses was determined in a dog model. Only IgG1 levels decreased after low-dose (+/- 4.5 Gy) TBI, but levels of all immunoglobulin classes fell after high-dose TBI (8.5 GyX1 or 2X6.0 Gy). After autologous bone marrow transplantation IgM levels were the first and IgE levels were the last to return to normal. After successful allogeneic bone marrow transplantation prolonged low IgM and IgE levels were found but IgA levels increased rapidly to over 150% of pretreatment values. A comparison of dogs with or without clinical signs or graft-versus-host disease (GVHD), revealed no differences in IgM levels. Dogs with GVHD had higher IgA but lower IgE levels. Dogs that rejected their allogeneic bone marrow cells showed significant early rises in IgE and IgA levels in comparison with dogs with GVHD. These results differ from the observations made on Ig levels in human bone marrow transplant patients. No significant differences in phytohemagglutinin stimulation tests were found between dogs with or without GVHD or dogs receiving an autologous transplant for the first four months after TBI and transplantation. An early primary or secondary involvement of humoral immunity in GVHD and graft rejection in dogs is postulated

  15. Total body irradiation in bone marrow transplantation: the influence of fractionation and delay of marrow infusion

    International Nuclear Information System (INIS)

    Lichter, A.S.; Tracy, D.; Lam, W.C.; Order, S.E.

    1980-01-01

    Bone marrow transplantation (BMT) after total body irradiation (TBI) and cyclophosphamide is being employed increasingly in the therapy of end stage leukemia. Interstitial pneumonitis (IP) represents a major acute toxicity after allogeneic transplantation. A more rapid reconstitution of lymphoid organs and bone marrow post transplant may result in increased immune competence and hence fewer opportunistic pulmonary infections and IP. By delaying the infusion of marrow to 72 hr after TBI (1250 rad at 7.5 rad/min) instead of the customary 24 hr, we can demonstrate an increase in initial repopulation of thymus, spleen and bone marrow, with syngeneic transplants in Lewis rats. Interstitial pneumonitis may also be caused, in part, by the pulmonary toxicity of large single exposures of TBI. Clinical and laboratory data suggest that fractionated TBI may be less toxic to the lung. When fractionated TBI (625 rad x 2, 7.5 rad/min) is compared to single dose TBI (1250 rad, 7.5 rad/min), and increased initial repopulation of lymphoid organs is observed when fractionated therapy is employed. Delay in marrow infusion and fractionation of TBI exposure may have clinical advantages in patients who receive BMT

  16. Biologically effective dose in total-body irradiation and hematopoietic stem cell transplantation

    International Nuclear Information System (INIS)

    Kal, H.B.; Kempen-Harteveld, M.L. van; Heijenbrok-Kal, M.H.; Struikmans, H.

    2006-01-01

    Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were pooled, and the pooled relative risk (RR) was calculated for the treatments with high BED values versus treatments with a low BED. BED-effect relationships were obtained. Results: RRs for the high BED treatments were significantly lower for relapse incidence, not significantly different for disease-free survival and treatment-related mortality, and significantly higher for overall survival. BED-effect relationships indicate a decrease in relapse incidence and treatment-related mortality and an increase in disease-free and overall survival with higher BED values. Conclusion: 'More dose is better', provided that a TBI setting is used limiting the BEDs of lungs, kidneys, and eye lenses. (orig.)

  17. Factors associated with pulmonary toxicity after myeloablative conditioning using fractionated total body irradiation

    International Nuclear Information System (INIS)

    Byun, Hwa Kyung; Yoon, Hong In; Cho, Jae Ho

    2017-01-01

    Pulmonary toxicities, including infectious pneumonia (IP) and idiopathic pneumonia syndrome (IPS), are serious side effects of total body irradiation (TBI) used for myeloablative conditioning. This study aimed to evaluate clinical factors associated with IP and IPS following TBI. Fifty-eight patients with hematologic malignancies who underwent TBI before allogeneic hematopoietic stem cell transplantation between 2005 and 2014 were reviewed. Most patients (91%) received 12 Gy in 1.5 Gy fractions twice a day. Pulmonary toxicities were diagnosed based on either radiographic evidence or reduced pulmonary function, and were subdivided into IP and IPS based on the presence or absence of concurrent infection. Pulmonary toxicities developed in 36 patients (62%); 16 (28%) had IP and 20 (34%) had IPS. IP was significantly associated with increased treatment-related mortality (p = 0.028) and decreased survival (p = 0.039). Multivariate analysis revealed that the risk of developing IPS was significantly higher in patients who received stem cells from a matched unrelated donor than from a matched sibling donor (p = 0.021; hazard ratio [HR] = 12.67; 95% confidence interval [CI], 1.46–110.30). Combining other conditioning agents with cyclophosphamide produced a higher tendency to develop IP (p = 0.064; HR = 6.19; 95% CI, 0.90–42.56). IP and IPS involve different risk factors and distinct pathogeneses that should be considered when planning treatments before and after TBI

  18. Long-term results of total body irradiation in adults with acute lymphoblastic leukemia

    International Nuclear Information System (INIS)

    Marnitz, Simone; Zich, Alexander; Budach, Volker; Jahn, Ulrich; Neumann, Oliver; Martus, Peter; Arnold, Renate

    2014-01-01

    The aim of this chart review of adult patients treated for acute lymphoblastic leukemia (ALL) with total body irradiation (TBI) was to evaluate early and late toxicity and long-term outcome. A total of 110 adult patients (34 ± 12 years) with ALL underwent TBI (6 fractions of 2 Gy for a total of 12 Gy) as a part of the treatment regimen before transplantation. Treatment-related toxicity, mortality, and hematologic outcome are reported. Mean follow-up was 70 months. The 2- and 5-year leukemia-free survival rates were 78 and 72 %, respectively. In all, 29 % (32/110) patients suffered from medullary recurrence after a median time of 7 months. Gender was the only statistically significant prognostic factor in terms of overall survival in favor of female patients. Treatment-related mortality and overall survival after 2 and 5 years were 16 and 22 %, and 60 and 52.7 %, respectively. The most frequent late reaction wascGVHD of the skin (n = 33, 30 %). In addition, 15.5 % (17/110 patients) suffered pulmonary symptoms, and 6 patients developed lung fibrosis. Eyes were frequently affected by the radiation (31/110 = 28 %); 12 of 110 patients (11 %) presented with symptoms from osteoporosis, 5 of 110 patients (4.5 %) developed hypothyreosis and 2 patients diabetes mellitus. Of the male patients, 11 % reported erectile dysfunction or loss of libido, while 2 of 36 women reported menopausal syndrome at the mean time of 28 months after treatment with requirement for substitution. No women became pregnant after treatment. No acute or late cardiac toxicities were documented in our patients. No secondary malignancies were documented. Although hematologic outcome was in the upper range of that reported in the literature, treatment-related mortality (TRM) and medullary recurrences remain a challenge. Sophisticated radiation techniques allow for decreasing toxicity to certain organs and/or dose escalation to the bone marrow in highly selected patients in order to improve therapeutic

  19. One common structural peculiarity of the Solar system bodies including the star, planets, satellites and resulting from their globes rotation

    Science.gov (United States)

    Kochemasov, G. G.

    2008-09-01

    Often observed a sensible difference in appearance and structure between tropical and extra-tropical zones of various heavenly bodies including rocky and gas planets, satellites and Sun compels to look for a common reason of such phenomenon. All bodies rotate and their spherical shape makes zones at different latitudes to have differing angular momenta as a distance to the rotation axis diminishes gradually from the equator to the poles (this is felt particularly when one launches rockets into space -preferable more cheap launches are from the equatorial regions - Kourou is better than Baikonur). One of remarkable changes occurs at tropics. As a single rotating planetary body tends to have angular momenta of its tectonic blocks equilibrated it starts mechanisms leveling this basic physical property. At tropical zones (bulged also due to the rotation ellipsoid) the outer shell - crust as a consequence tends to be destroyed, sunk, subsided and shrunk; a density of crust material changes; the atmosphere reacts changing chemistry and structure; in terrestrial anthroposphere man looses its mass and stature. But according to the Le Chatelier rule mechanisms with an opposing tendency also begin to act. At Earth the wide planetary long tropical zone is marked by destruction of the crust. It is demonstrated by development of numerous islands of the Malay Archipelago (the Sunda Isls., Maluku Isls, Philippines) between the Southeastern Asia and Australia. In Africa and South America huge depressions of the Congo and Amazon Rivers develops where the Archean crust is subsided to depths of more than 2 km. In the Pacific along the equator numerous islands of Micronesia occur. Subsidence of the basaltic oceanic crust is followed by an intensive folding and faulting of basalt and sedimentary layers (Fig. 1) as a larger mass must be held by a smaller space (a planetary radius is diminished). The central Atlantic is very demonstrative in this sense suffering huge transform fault

  20. Intake at a single, palatable buffet test meal is associated with total body fat and regional fat distribution in children.

    Science.gov (United States)

    Fearnbach, S Nicole; Thivel, David; Meyermann, Karol; Keller, Kathleen L

    2015-09-01

    Previous studies testing the relationship between short-term, ad libitum test-meal intake and body composition in children have shown inconsistent relationships. The objective of this study was to determine whether children's intake at a palatable, buffet meal was associated with body composition, assessed by dual-energy X-ray absorptiometry (DXA). A sample of 71 children (4-6 years) participated in 4 sessions where ad libitum food intake was measured. Children's intake at two of the test-meals was retained for the present analysis: a baseline meal consisting of moderately palatable foods and a highly palatable buffet including sweets, sweet-fats, and savory-fats. On the last visit, anthropometrics and DXA were assessed to determine child body composition. Children consumed significantly more calories at the palatable buffet compared to the baseline test-meal. Children's total fat-free mass was positively associated with intake at both the baseline meal and the palatable buffet meal. Total energy intake at both meals and intake of savory-fats at the palatable buffet were positively associated with children's total fat mass, total percent body fat, and percent android fat. Intake of sweet-fats was associated with child fat-free mass index. Intake of sweets was not correlated with body composition. Children's intake at a palatable test-meal, particularly of savory-fat foods, was associated with measures of total and regional body fat. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Nation-wide anthropometric survey data in Japan to determine dimensions of total-body phantom for Reference Japanese Man

    International Nuclear Information System (INIS)

    Togo, Masami

    1990-01-01

    In order to estimate radiation dose in Japanese population accurately, a Reference Japanese Man, whose stature and body weight are 170cm and 60kg respectively, is indispensable. The MIRD 5 total-body phantom has only 8 dimensions, i.e. total head height, head length, head breadth, trunk length, trunk breadth, leg length, and breadth and depth of a leg model at its lower end. Based on Japanese anthropometric data, the dimensions were determined and its mathematical descriptions were given. In Japan, annual statistical data of stature, body weight, chest circumference and sitting height for all Japan by sex and age are published. But other nation-wide survey data necessary for determining dimensions of total-body phantom of Reference Japanese Man, are unavailable. Much more national anthropometric data of every kind necessary for defining phantoms must be compiled. (author)

  2. Effect of BCNU combined with total body irradiation or cyclophosphamide on survival of dogs after autologous marrow grafts

    International Nuclear Information System (INIS)

    Paterson, A.H.G.; English, D.

    1979-01-01

    Dogs were treated with either: (1) 750 rad total body irradiation; (2) BCNU 2 or 4 mg/kg IV 48 hours prior to 750 rad total body irradiation; or (3) BCNU 4 mg/kg IV plus cyclophosphamide 30 mg/kg IV. Results showed that of 11 dogs who received 750 rad total body irradiation and did not receive cryopreserved autologous bone marrow cells, none survived, compared to an 88% survival (31 of 35 dogs) after 750 rad total body irradiation if the dogs received stored autologous bone marrow cells. However, when the dogs were treated with BCNU 2 or 4 mg/kg prior to 750 rad total body irradiation the survival rate, despite infusion of autologous bone marrow cells, dropped to 25% (3 of 12 dogs) for BCNU 2 mg/kg, and 17% (2 of 12 dogs) for BCNU 4 mg/kg. This effect did not seem to be due to direct serum inhibition of hemopoietic cell proliferation since serum obtained at various intervals after BCNU administrations failed to inhibit CFU growth in vitro. The dogs died from hemorrhage and infection; at autopsy there was hemorrhagic pneumonitis and intestinal ulcerations with petechial hemorrhages, suggesting that the combination of BCNU and total body irradiation may have synergistic toxicity on the canine gastro-intestinal tract. When BCNU was combined with cyclophosphamide, reversal of marrow toxicity occurred in 54% (6 of 11 dogs) with stored autologous bone marrow cells compared to no survival (0 of 8 dogs) with stored autologous bone marrow cells. Thus while autologous bone marrow grafts are useful for reversal of marrow toxicity due to many therapeutic protocols, such grafts alone may not provide protection against toxicity due to the combination of high dosage BCNU and total body irradiation

  3. Statistical analysis of dose heterogeneity in circulating blood: Implications for sequential methods of total body irradiation

    International Nuclear Information System (INIS)

    Molloy, Janelle A.

    2010-01-01

    Purpose: Improvements in delivery techniques for total body irradiation (TBI) using Tomotherapy and intensity modulated radiation therapy have been proven feasible. Despite the promise of improved dose conformality, the application of these ''sequential'' techniques has been hampered by concerns over dose heterogeneity to circulating blood. The present study was conducted to provide quantitative evidence regarding the potential clinical impact of this heterogeneity. Methods: Blood perfusion was modeled analytically as possessing linear, sinusoidal motion in the craniocaudal dimension. The average perfusion period for human circulation was estimated to be approximately 78 s. Sequential treatment delivery was modeled as a Gaussian-shaped dose cloud with a 10 cm length that traversed a 183 cm patient length at a uniform speed. Total dose to circulating blood voxels was calculated via numerical integration and normalized to 2 Gy per fraction. Dose statistics and equivalent uniform dose (EUD) were calculated for relevant treatment times, radiobiological parameters, blood perfusion rates, and fractionation schemes. The model was then refined to account for random dispersion superimposed onto the underlying periodic blood flow. Finally, a fully stochastic model was developed using binomial and trinomial probability distributions. These models allowed for the analysis of nonlinear sequential treatment modalities and treatment designs that incorporate deliberate organ sparing. Results: The dose received by individual blood voxels exhibited asymmetric behavior that depended on the coherence among the blood velocity, circulation phase, and the spatiotemporal characteristics of the irradiation beam. Heterogeneity increased with the perfusion period and decreased with the treatment time. Notwithstanding, heterogeneity was less than ±10% for perfusion periods less than 150 s. The EUD was compromised for radiosensitive cells, long perfusion periods, and short treatment times

  4. Statistical analysis of dose heterogeneity in circulating blood: implications for sequential methods of total body irradiation.

    Science.gov (United States)

    Molloy, Janelle A

    2010-11-01

    Improvements in delivery techniques for total body irradiation (TBI) using Tomotherapy and intensity modulated radiation therapy have been proven feasible. Despite the promise of improved dose conformality, the application of these "sequential" techniques has been hampered by concerns over dose heterogeneity to circulating blood. The present study was conducted to provide quantitative evidence regarding the potential clinical impact of this heterogeneity. Blood perfusion was modeled analytically as possessing linear, sinusoidal motion in the craniocaudal dimension. The average perfusion period for human circulation was estimated to be approximately 78 s. Sequential treatment delivery was modeled as a Gaussian-shaped dose cloud with a 10 cm length that traversed a 183 cm patient length at a uniform speed. Total dose to circulating blood voxels was calculated via numerical integration and normalized to 2 Gy per fraction. Dose statistics and equivalent uniform dose (EUD) were calculated for relevant treatment times, radiobiological parameters, blood perfusion rates, and fractionation schemes. The model was then refined to account for random dispersion superimposed onto the underlying periodic blood flow. Finally, a fully stochastic model was developed using binomial and trinomial probability distributions. These models allowed for the analysis of nonlinear sequential treatment modalities and treatment designs that incorporate deliberate organ sparing. The dose received by individual blood voxels exhibited asymmetric behavior that depended on the coherence among the blood velocity, circulation phase, and the spatiotemporal characteristics of the irradiation beam. Heterogeneity increased with the perfusion period and decreased with the treatment time. Notwithstanding, heterogeneity was less than +/- 10% for perfusion periods less than 150 s. The EUD was compromised for radiosensitive cells, long perfusion periods, and short treatment times. However, the EUD was

  5. One hundred patients with acute leukemia treated by chemotherapy, total body irradiation, and allogeneic marrow transplantation

    International Nuclear Information System (INIS)

    Thomas, E.D.; Buckner, C.D.; Banaji, M.

    1977-01-01

    One hundred patients, 54 with acute myelogenous leukemia (AML) and 46 with acute lymphoblastic leukemia (ALL), considered to be in the end stages of their disease, after combination chemotherapy were treated by marrow transplantation. All patients were given a marrow graft from an HLA-identical sibling after receiving 1000-rad total body irradiation (TBI). One group of 43 patients was given cyclophosphamide (CY), 60 mg/kg on each of 2 days, 5 and 4 days before TBI. In a second group of 31 patients, additional chemotherapy was given before CY and TBI. In a third group of 19 patients, BCNU was given before CY and TBI. A fourth group of 7 patients received other chemotherapy regimens before TBI. Six patients died 3 to 17 days after marrow infusion without evidence of engraftment. Ninety-four patients were engrafted rejected and only one patient rejected the graft. Thirteen patients are alive with a marrow graft, on no maintenance antileukemic therapy, and without recurrent leukemia 1--4 1 / 2 yr after transplantation. Three have chronic graft-versus-host disease (GVHD). The relapse rate appeared to be relatively constant over the first 2 yr and was extremely low after that time. Neither survival nor leukemic relapse appeared to be influenced by the type of leukemia nor by the preparative chemotherapy regimen given before TBI. Patients in fair clinical condition at the time of transplantation showed significantly longer survival times than patients in poor condition (p = 0.001). This observation, coupled with the observation that some patients may be cured of their disease, indicates that marrow transplantation should now be undertaken earlier in the management of patients with acute leukemia who have an HLA-matched sibling marrow donor

  6. Enhanced responses to tumor immunization following total body irradiation are time-dependent.

    Directory of Open Access Journals (Sweden)

    Adi Diab

    Full Text Available The development of successful cancer vaccines is contingent on the ability to induce effective and persistent anti-tumor immunity against self-antigens that do not typically elicit immune responses. In this study, we examine the effects of a non-myeloablative dose of total body irradiation on the ability of tumor-naïve mice to respond to DNA vaccines against melanoma. We demonstrate that irradiation followed by lymphocyte infusion results in a dramatic increase in responsiveness to tumor vaccination, with augmentation of T cell responses to tumor antigens and tumor eradication. In irradiated mice, infused CD8(+ T cells expand in an environment that is relatively depleted in regulatory T cells, and this correlates with improved CD8(+ T cell functionality. We also observe an increase in the frequency of dendritic cells displaying an activated phenotype within lymphoid organs in the first 24 hours after irradiation. Intriguingly, both the relative decrease in regulatory T cells and increase in activated dendritic cells correspond with a brief window of augmented responsiveness to immunization. After this 24 hour window, the numbers of dendritic cells decline, as does the ability of mice to respond to immunizations. When immunizations are initiated within the period of augmented dendritic cell activation, mice develop anti-tumor responses that show increased durability as well as magnitude, and this approach leads to improved survival in experiments with mice bearing established tumors as well as in a spontaneous melanoma model. We conclude that irradiation can produce potent immune adjuvant effects independent of its ability to induce tumor ablation, and that the timing of immunization and lymphocyte infusion in the irradiated host are crucial for generating optimal anti-tumor immunity. Clinical strategies using these approaches must therefore optimize such parameters, as the correct timing of infusion and vaccination may mean the difference

  7. Patterns of Relapse in High-Risk Neuroblastoma Patients Treated With and Without Total Body Irradiation

    International Nuclear Information System (INIS)

    Li, Richard; Polishchuk, Alexei; DuBois, Steven; Hawkins, Randall; Lee, Stephanie W.; Bagatell, Rochelle; Shusterman, Suzanne; Hill-Kayser, Christine; Al-Sayegh, Hasan; Diller, Lisa; Haas-Kogan, Daphne A.; Matthay, Katherine K.; London, Wendy B.

    2017-01-01

    Purpose: External beam radiation therapy to initial sites of disease may influence relapse patterns in high-risk neuroblastoma. However, the effect of systemic irradiation by use of total body irradiation (TBI) on anatomic patterns of relapse has not previously been investigated. Methods and Materials: We retrospectively analyzed patients receiving definitive treatment of high-risk neuroblastoma with subsequent relapse in bony metastatic sites, with a date of relapse between January 1, 1997, and December 31, 2012. Anatomic sites of disease, defined by metaiodobenzylguanidine (MIBG) avidity, were compared at diagnosis and at first relapse. The Fisher exact test was performed to compare relapse in initially involved sites between patients treated with and without TBI. Results: Seventy-four patients with a median age at diagnosis of 3.5 years (range, 0.3-15.3 years) had relapse in 227 sites of MIBG-avid metastatic disease, with a median time to relapse of 1.8 years. Of the 227 sites of first relapse, 154 sites (68%) were involved at diagnosis. When we compared relapse patterns in patients treated with and without TBI, 12 of 23 patients (52%) treated with TBI had relapse in ≥1 previously MIBG-avid site of disease whereas 40 of 51 patients (78%) treated without TBI had relapse in ≥1 previously MIBG-avid site of disease (P=.03). Conclusions: Patients treated with systemic irradiation in the form of TBI were significantly less likely to have relapse in prior sites of disease. These findings support further investigation into the role of radiopharmaceutical therapies in curative multimodality therapy.

  8. Hyperfractionated total body irradiation for bone marrow transplantation. Results in seventy leukemia patients with allogeneic transplants

    International Nuclear Information System (INIS)

    Shank, B.; Chu, F.C.H.; Dinsmore, R.

    1983-01-01

    From May, 1979 to March, 1981, 76 leukemia patients were prepared for bone marrow transplantation (BMT) with a new hyperfractionated total body irradiation (TBI) regimen (1320 cGy in 11 fractions, 3x/day), followed by cyclophosphamide, 60 mg/kg, for two days. Partial lung shielding was done on each treatment, with supplemental electron beam treatments of the chest wall to compensate, and of the testes, a sanctuary site. This regimen was initiated to potentially reduce fatal interstitial pneumonitis as well as decrease leukemic relapse. Overall actuarial survival at 1 year for acute non-lymphocytic leukemia (ANLL) patients is 63%, while relapse-free survival at 1 year is 53%. On the other hand, for acute lymphocytic leukemia (ALL) patients, there is no significant difference between relapse or remission patients with regard to overall survival or relapse-free survival, when relapse is defined as > 5% blasts in the marrow at the time of cytoreduction. Overall actuarial survival at 1 year for ALL is 61% and relapse-free survival is 45% at 1 year. Fatal interstitial pneumonitis has dropped to 18% compared with 50% in our previous single-dose TBI regimen (1000 cGy), in which the same doses of cyclophosphamide were given prior to TBI. In conclusion, not only has fatal interstitial pneumonitis been reduced by hyperfractionation and partial lung blocking, but there may be a survival advantage in ALL patients in relapse, who have a survival equal to that of remission patients. This may indicate a greater cell kill with the higher dose (1320 cGy) attained with this regimen, in these patients with a higher leukemic cell burden

  9. Neurobehavioral toxicity of total body irradiation: a follow-up in long-term survivors

    International Nuclear Information System (INIS)

    Peper, Martin; Steinvorth, Sarah; Schraube, Peter; Fruehauf, Stefan; Haas, Rainer; Kimmig, Bernhard N.; Lohr, Frank; Wenz, Frederik; Wannenmacher, Michael

    2000-01-01

    Purpose: Total body irradiation (TBI) in preparation for bone marrow transplantation (BMT) is a routine treatment of hematological malignancy. A retrospective and a prospective group study of long-term cerebral side effects was performed, with a special emphasis on neurobehavioral toxicity effects. Methods and Materials: Twenty disease-free patients treated with hyperfractionated TBI (14.4 Gy, 12 x 1.2 Gy, 4 days), 50 mg/kg cyclophosphamide, and autologous BMT (mean age 38 years, range 17-52 years; age at TBI 35 years, 16-50 years; follow-up time 32 months, 9-65 months) participated in a neuropsychological, neuroradiological, and neurological examination. Data were compared to 14 patients who were investigated prior to TBI. Eleven patients with renal insufficiencies matched for sex and age (38 years, 20-52 years) served as controls. In a longitudinal approach, neuropsychological follow-up data were assessed in 12 long-term survivors (45 years, 23-59 years; follow-up time 8.8 years, 7-10.8 years; time since diagnosis 10.1 years, 7.5-14.2 years). Results: No evidence of neurological deficits was found in post-TBI patients except one case of peripheral movement disorder of unknown origin. Some patients showed moderate brain atrophy. Neuropsychological assessment showed a subtle reduction of memory performance of about one standard deviation. Cognitive decline in individual patients appeared to be associated with pretreatment (brain irradiation, intrathecal methotrexate). Ten-years post disease onset, survivors without pretreatment showed behavioral improvement up to the premorbid level. Conclusion: The incidence of long-term neurobehavioral toxicity was very low for the present TBI/BMT regimen

  10. Poster - 42: TB - ARC: A Total Body photon ARC technique using a commercially available linac

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Michael D. C.; Ruo, Russell; Patrocinio, Horacio J.; Poon, Emily; Freeman, Carolyn; Hijal, Tarek; Parker, William [McGill University Health Centre (Canada)

    2016-08-15

    We have developed a total body photon irradiation technique using multiple overlapping open field arcs (TB-ARC). This simple technique uses predetermined arc-weights, with MUs calculated as a function of prescription depth only. Patients lie on a stretcher, in the prone/supine treatment position with AP/PA arcs. This treatment position has many advantages including ease of delivery (especially for tall, pediatric or compromised patients), dose uniformity, simplicity for organ shielding, and imaging capabilities. Using a Varian TrueBeam linac, 14 arcs using 40×40 cm{sup 2} 6 MV open photon beams, sweeping across 10 degrees each, complete a 140 degree arc. The nominal SSD at zero degrees is 200 cm. Arcs at the sweep limits (+/− 70 degrees) are differentially weighted and deliver a dose within 10% of the prescription on central axis, at a depth of 10 cm over a superior-inferior length of 275 cm. CT planning using Varian Eclipse enables dose evaluation. A custom made beam spoiler, consisting of a 2.5 m sheet of polycarbonate (6 mm thick) increases the surface dose from 45% to 90%. This beam spoiler also serves as a support in the event that differential attenuation is required for organs such as lung, heart, liver, kidneys. The geometry of the sweeping beam technique limits organ dose (using varying thicknesses of melting alloy) to about 20% and 40% of prescription at dmax and midplane respectively. Digital imaging with a portable DR cassette enables proper attenuator location prior to treatment.

  11. Patterns of Relapse in High-Risk Neuroblastoma Patients Treated With and Without Total Body Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Richard [Harvard Medical School, Boston, Massachusetts (United States); Brigham and Women' s Hospital, Boston, Massachusetts (United States); Polishchuk, Alexei [School of Medicine, University of California San Francisco, San Francisco, California (United States); DuBois, Steven [Harvard Medical School, Boston, Massachusetts (United States); Dana-Farber/Boston Children' s Cancer and Blood Disorders Center, Boston, Massachusetts (United States); Hawkins, Randall [School of Medicine, University of California San Francisco, San Francisco, California (United States); Lee, Stephanie W. [Brigham and Women' s Hospital, Boston, Massachusetts (United States); Bagatell, Rochelle [Children' s Hospital of Philadelphia, Philadelphia, Pennsylvania (United States); Shusterman, Suzanne [Harvard Medical School, Boston, Massachusetts (United States); Dana-Farber/Boston Children' s Cancer and Blood Disorders Center, Boston, Massachusetts (United States); Hill-Kayser, Christine [Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Al-Sayegh, Hasan [Brigham and Women' s Hospital, Boston, Massachusetts (United States); Dana-Farber/Boston Children' s Cancer and Blood Disorders Center, Boston, Massachusetts (United States); Diller, Lisa [Harvard Medical School, Boston, Massachusetts (United States); Dana-Farber/Boston Children' s Cancer and Blood Disorders Center, Boston, Massachusetts (United States); Haas-Kogan, Daphne A. [Harvard Medical School, Boston, Massachusetts (United States); Brigham and Women' s Hospital, Boston, Massachusetts (United States); Dana-Farber/Boston Children' s Cancer and Blood Disorders Center, Boston, Massachusetts (United States); Matthay, Katherine K. [School of Medicine, University of California San Francisco, San Francisco, California (United States); London, Wendy B. [Harvard Medical School, Boston, Massachusetts (United States); Dana-Farber/Boston Children' s Cancer and Blood Disorders Center, Boston, Massachusetts (United States); and others

    2017-02-01

    Purpose: External beam radiation therapy to initial sites of disease may influence relapse patterns in high-risk neuroblastoma. However, the effect of systemic irradiation by use of total body irradiation (TBI) on anatomic patterns of relapse has not previously been investigated. Methods and Materials: We retrospectively analyzed patients receiving definitive treatment of high-risk neuroblastoma with subsequent relapse in bony metastatic sites, with a date of relapse between January 1, 1997, and December 31, 2012. Anatomic sites of disease, defined by metaiodobenzylguanidine (MIBG) avidity, were compared at diagnosis and at first relapse. The Fisher exact test was performed to compare relapse in initially involved sites between patients treated with and without TBI. Results: Seventy-four patients with a median age at diagnosis of 3.5 years (range, 0.3-15.3 years) had relapse in 227 sites of MIBG-avid metastatic disease, with a median time to relapse of 1.8 years. Of the 227 sites of first relapse, 154 sites (68%) were involved at diagnosis. When we compared relapse patterns in patients treated with and without TBI, 12 of 23 patients (52%) treated with TBI had relapse in ≥1 previously MIBG-avid site of disease whereas 40 of 51 patients (78%) treated without TBI had relapse in ≥1 previously MIBG-avid site of disease (P=.03). Conclusions: Patients treated with systemic irradiation in the form of TBI were significantly less likely to have relapse in prior sites of disease. These findings support further investigation into the role of radiopharmaceutical therapies in curative multimodality therapy.

  12. Cataract after total body irradiation and bone marrow transplantation degree of visual impairment

    International Nuclear Information System (INIS)

    Kempen-Harteveld, M. Loes van; Struikmans, Henk; Kal, Henk B.; Tweel, Ingeborg van der; Mourits, Maarten P.; Verdonck, Leo F.; Schipper, Jan; Battermann, Jan J.

    2002-01-01

    Purpose: To assess the degree of visual impairment as a result of cataract formation after total body irradiation (TBI) for bone marrow transplantation. Methods and Materials: The data from 93 patients who received TBI in 1 or 2 fractions as a part of their conditioning regimen for bone marrow transplantation were analyzed with respect to the degree of visual impairment as a result of cataract formation. The probability to develop severe visual impairment (SVI) was determined for all patients, and the degree of visual impairment was assessed for 56 patients with stabilized cataract, using three categories: no, mild, or severe. Results: For all 93 patients, the probability of developing a cataract causing SVI was 0.44. For allogeneic patients, it was 0.33 without and 0.71 with steroid treatment (p<0.001). All SVI-free probability curves reached a plateau distinct from the cataract-free curves. Apparently, cataracts developing late in the follow-up period rarely cause SVI. Of the patients with stabilized cataract, 32% had no visual impairment, 16% had mild, and 52% severe impairment. No or mild visual impairment was present in 61% of all patients with stable cataract and no steroid treatment compared with only 13% of the patients treated with steroids (p=0.035). Conclusion: SVI occurs in only some of the patients (52%) with stable cataract after TBI for bone marrow transplantation in 1 or 2 fractions. Steroid treatment markedly increases the probability of developing visual problems as result of a cataract after TBI

  13. Acute Radiation Syndrome Severity Score System in Mouse Total-Body Irradiation Model.

    Science.gov (United States)

    Ossetrova, Natalia I; Ney, Patrick H; Condliffe, Donald P; Krasnopolsky, Katya; Hieber, Kevin P

    2016-08-01

    Radiation accidents or terrorist attacks can result in serious consequences for the civilian population and for military personnel responding to such emergencies. The early medical management situation requires quantitative indications for early initiation of cytokine therapy in individuals exposed to life-threatening radiation doses and effective triage tools for first responders in mass-casualty radiological incidents. Previously established animal (Mus musculus, Macaca mulatta) total-body irradiation (γ-exposure) models have evaluated a panel of radiation-responsive proteins that, together with peripheral blood cell counts, create a multiparametic dose-predictive algorithm with a threshold for detection of ~1 Gy from 1 to 7 d after exposure as well as demonstrate the acute radiation syndrome severity score systems created similar to the Medical Treatment Protocols for Radiation Accident Victims developed by Fliedner and colleagues. The authors present a further demonstration of the acute radiation sickness severity score system in a mouse (CD2F1, males) TBI model (1-14 Gy, Co γ-rays at 0.6 Gy min) based on multiple biodosimetric endpoints. This includes the acute radiation sickness severity Observational Grading System, survival rate, weight changes, temperature, peripheral blood cell counts and radiation-responsive protein expression profile: Flt-3 ligand, interleukin 6, granulocyte-colony stimulating factor, thrombopoietin, erythropoietin, and serum amyloid A. Results show that use of the multiple-parameter severity score system facilitates identification of animals requiring enhanced monitoring after irradiation and that proteomics are a complementary approach to conventional biodosimetry for early assessment of radiation exposure, enhancing accuracy and discrimination index for acute radiation sickness response categories and early prediction of outcome.

  14. External-beam boost prior to total-body irradiation in relapsed NHL transplant patients

    Energy Technology Data Exchange (ETDEWEB)

    Monson, Jedidiah M; Neuberg, Donna; Freedman, Arnold S; Tarbell, Nancy J; Nadler, Lee M; Mauch, Peter

    1995-07-01

    PURPOSE: To determine the impact of an external beam boost (EBB) on the outcome, relapse pattern and normal tissue toxicities of patients undergoing total-body irradiation (TBI) prior to bone marrow transplantation (BMT) for relapsed NHL. MATERIALS AND METHODS: Between 1982 and 1994, 299 patients at our institution underwent BMT for relapsed NHL. Patients underwent induction chemotherapy (CT) followed by conditioning with cyclophosphamide and 12 Gy TBI delivered in 6 fractions over 3 days. A total of 77 patients had persistent gross disease, defined as 2 cm or greater, after induction CT and received an EBB prior to BMT (EBB cohort). The median EBB dose was 28.8 Gy (range, 5-63), the median field size was 13 cm{sup 2} (range, 5-29.4) and the median time from EBB to BMT was 3 weeks (range, 1-20). A total of 222 patients were free of measurable disease or had disease measuring <2cm after CT and did not receive EBB (no-EBB cohort). To assess normal tissue toxicity, patients' simulation films and/or treatment records were reviewed for all 77 patients treated with local EBB and estimates were made of the percentage lung, heart and kidney in the radiation field. RESULTS: A total of 79 of 222 patients (36%) in the no-EBB cohort have relapsed; 33 of 77 patients (43%) in the EBB cohort have relapsed (p=0.28, by Fisher exact test). Median time to relapse after BMT was 54 months for the no-EBB cohort and 38 months for the EBB cohort (p=0.26, by log-rank test). The 3-year actuarial freedom from relapse (deaths in remission censored) was 59% for the no-EBB cohort (90% CI: 52-66%) and 51% for the EBB cohort (90% CI: 40-62%). Data on site of relapse was available for 101 of the 112 relapses (75 no-EBB, 26 EBB). For the no-EBB cohort 33 of 75 relapses (44%) were in sites of prior nodal disease only. For the EBB cohort, 12 of 26 relapses (46%) were in sites of prior nodal disease only, of these, only 6 (23%) were within the EBB treatment field. A total of 26 patients had thoracic

  15. Urea, creatinine, uric acid, and phosphate spaces and their relationship to total body water during chronic hemodialysis

    International Nuclear Information System (INIS)

    Ericsson, F.; Odar-Cederloef, I.E.; Eriksson, C.G.; Lindgren, S.; Kjellstrand, C.M.

    1988-01-01

    The authors determined total body water (TBW) with tritium in 11 patients on chronic hemodialysis and compared this space to that estimated by 60% of body weight, and removal spaces of urea, creatinine, uric acid, and phosphate (PO 4 ). The latter spaces were determined by dividing the total amount of substance (measured in total dialysate) by pre- minus post-dialysis concentrations. Body water X 0.6 was more than 10% less than the tritium space, and showed a maximal variation of 10 liters, or 24%. The removal space of urea was 80% of the tritium space, but correlated closely with it. The difference between total body water and urea removal space was variable and dependent on fluid excess (edema) in the patients. Creatinine, uric acid, and phosphate removal spaces were highly variable and not correlated to total body water. The authors suggest that actual measured TBW should be used, rather than estimations using BW X 0.6, for V in K X T/V, where K = clearance, T = duration of dialysis, and V = the removal space of urea. Furthermore, one may need to introduce a correction factor for urea removal space over TBW in the equation to allow better quantification of dialysis in edematous patients and during very fast dialyses

  16. Long-term results of total body irradiation in adults with acute lymphoblastic leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Marnitz, Simone; Zich, Alexander; Budach, Volker; Jahn, Ulrich; Neumann, Oliver [Charite University Medicine, Department of Radiation Oncology, Berlin (Germany); Martus, Peter [University Tuebingen, Institute of Clinical Epidemiology and Applied Biostatistics, Tuebingen (Germany); Arnold, Renate [Charite University Medicine, Campus CVK, Department of Hematology and Oncology, Bone Marrow Transplant Unit, Berlin (Germany)

    2014-05-15

    The aim of this chart review of adult patients treated for acute lymphoblastic leukemia (ALL) with total body irradiation (TBI) was to evaluate early and late toxicity and long-term outcome. A total of 110 adult patients (34 ± 12 years) with ALL underwent TBI (6 fractions of 2 Gy for a total of 12 Gy) as a part of the treatment regimen before transplantation. Treatment-related toxicity, mortality, and hematologic outcome are reported. Mean follow-up was 70 months. The 2- and 5-year leukemia-free survival rates were 78 and 72 %, respectively. In all, 29 % (32/110) patients suffered from medullary recurrence after a median time of 7 months. Gender was the only statistically significant prognostic factor in terms of overall survival in favor of female patients. Treatment-related mortality and overall survival after 2 and 5 years were 16 and 22 %, and 60 and 52.7 %, respectively. The most frequent late reaction wascGVHD of the skin (n = 33, 30 %). In addition, 15.5 % (17/110 patients) suffered pulmonary symptoms, and 6 patients developed lung fibrosis. Eyes were frequently affected by the radiation (31/110 = 28 %); 12 of 110 patients (11 %) presented with symptoms from osteoporosis, 5 of 110 patients (4.5 %) developed hypothyreosis and 2 patients diabetes mellitus. Of the male patients, 11 % reported erectile dysfunction or loss of libido, while 2 of 36 women reported menopausal syndrome at the mean time of 28 months after treatment with requirement for substitution. No women became pregnant after treatment. No acute or late cardiac toxicities were documented in our patients. No secondary malignancies were documented. Although hematologic outcome was in the upper range of that reported in the literature, treatment-related mortality (TRM) and medullary recurrences remain a challenge. Sophisticated radiation techniques allow for decreasing toxicity to certain organs and/or dose escalation to the bone marrow in highly selected patients in order to improve therapeutic

  17. Monte carlo efficiency calibration of a neutron generator-based total-body irradiator

    Science.gov (United States)

    The increasing prevalence of obesity world-wide has focused attention on the need for accurate body composition assessments, especially of large subjects. However, many body composition measurement systems are calibrated against a single-sized phantom, often based on the standard Reference Man mode...

  18. Influence of rotational setup error on tumor shift in bony anatomy matching measured with pulmonary point registration in stereotactic body radiotherapy for early lung cancer

    International Nuclear Information System (INIS)

    Suzuki, Osamu; Nishiyama, Kinji; Ueda, Yoshihiro; Miyazaki, Masayoshi; Tsujii, Katsutomo

    2012-01-01

    The objective of this study was to examine the correlation between the patient rotational error measured with pulmonary point registration and tumor shift after bony anatomy matching in stereotactic body radiotherapy for lung cancer. Twenty-six patients with lung cancer who underwent stereotactic body radiotherapy were the subjects. On 104 cone-beam computed tomography measurements performed prior to radiation delivery, rotational setup errors were measured with point registration using pulmonary structures. Translational registration using bony anatomy matching was done and the three-dimensional vector of tumor displacement was measured retrospectively. Correlation among the three-dimensional vector and rotational error and vertebra-tumor distance was investigated quantitatively. The median and maximum rotational errors of the roll, pitch and yaw were 0.8, 0.9 and 0.5, and 6.0, 4.5 and 2.5, respectively. Bony anatomy matching resulted in a 0.2-1.6 cm three-dimensional vector of tumor shift. The shift became larger as the vertebra-tumor distance increased. Multiple regression analysis for the three-dimensional vector indicated that in the case of bony anatomy matching, tumor shifts of 5 and 10 mm were expected for vertebra-tumor distances of 4.46 and 14.1 cm, respectively. Using pulmonary point registration, it was found that the rotational setup error influences the tumor shift. Bony anatomy matching is not appropriate for hypofractionated stereotactic body radiotherapy with a tight margin. (author)

  19. Conversion of the magnetic field measured in three components on the magnetic sensor body's random coordinate system into three components on geographical coordinate system through quaternion rotation.

    Science.gov (United States)

    LIM, M.; PARK, Y.; Jung, H.; SHIN, Y.; Rim, H.; PARK, C.

    2017-12-01

    To measure all components of a physical property, for example the magnetic field, is more useful than to measure its magnitude only in interpretation and application thereafter. To convert the physical property measured in 3 components on a random coordinate system, for example on moving magnetic sensor body's coordinate system, into 3 components on a fixed coordinate system, for example on geographical coordinate system, by the rotations of coordinate system around Euler angles for example, we should have the attitude values of the sensor body in time series, which could be acquired by an INS-GNSS system of which the axes are installed coincident with those of the sensor body. But if we want to install some magnetic sensors in array at sea floor but without attitude acquisition facility of the magnetic sensors and to monitor the variation of magnetic fields in time, we should have also some way to estimate the relation between the geographical coordinate system and each sensor body's coordinate system by comparison of the vectors only measured on both coordinate systems on the assumption that the directions of the measured magnetic field on both coordinate systems are the same. For that estimation, we have at least 3 ways. The first one is to calculate 3 Euler angles phi, theta, psi from the equation Vgeograph = Rx(phi) Ry(theta) Rz(psi) Vrandom, where Vgeograph is the vector on geographical coordinate system etc. and Rx(phi) is the rotation matrix around the x axis by the angle phi etc. The second one is to calculate the difference of inclination and declination between the 2 vectors on spherical coordinate system. The third one, used by us for this study, is to calculate the angle of rotation along a great circle around the rotation axis, and the direction of the rotation axis. We installed no. 1 and no. 2 FVM-400 fluxgate magnetometers in array near Cheongyang Geomagnetic Observatory (IAGA code CYG) and acquired time series of magnetic fields for CYG and for

  20. Evaluation of nuclear magnetic resonance spectroscopy for determination of deuterium abundance in body fluids: application to measurement of total-body water in human infants

    International Nuclear Information System (INIS)

    Rebouche, C.J.; Pearson, G.A.; Serfass, R.E.; Roth, C.W.; Finley, J.W.

    1987-01-01

    Nuclear magnetic resonance (NMR) spectroscopy was used to quantitate abundance of 2H in body water of human infants. This method provides precise measurement of total-body water without the extensive sample preparation requirements of previously described methods for determination of 2H content in body fluids. 2H2O (1 g/kg body weight) was administered to infants and saliva and urine were collected for up to 5 h. An internal standard was added directly to the fluid specimen and 2H enrichment in water was measured by NMR spectroscopy. Working range of deuterium abundance was 0.04-0.32 atom %. Coefficients of variation for saliva samples at 0.20 atom % 2H was 1.97%. 2H content in urine and saliva water reached a plateau by 4 h after administration, and amounts in the two fluids were virtually identical. Mean total-body water determination for six infants was 58.3 +/- 5.8% of body weight (range 53-66%)

  1. Measurement of total electron content of midlatitude ionosphere and protonosphere via Faraday rotation and group relay techniques using transmission from geostationary satellites ATS-3 and ATS-6

    Science.gov (United States)

    Paul, M. P.

    1982-01-01

    Measurement of integrated columnar electron content and total electron content for the local ionosphere and the overlying protonosphere via Faraday rotation and group delay techniques has proven very useful. A field station was established having the geographic location of 31.5 deg N latitude and 91.06 deg W longitude to accomplish these objectives. A polarimeter receiving system was set up in the beginning to measure the Faraday rotation of 137.35 MHz radio signal from geostationary satellite ATS 3 to yield the integrated columnar electron content of the local ionosphere. The measurement was continued regularly, and the analysis of the data thus collected provided a synopsis of the statistical variation of the ionosphere along with the transient variations that occurred during the periods of geomagnetic and other disturbances.

  2. Longitudinal measurements of total body water and body composition in healthy volunteers by online breath deuterium measurement and other near-subject methods

    Czech Academy of Sciences Publication Activity Database

    Engel, B.; Španěl, Patrik; Smith, D.; Diskin, A. M.; Davis, S. J.

    2005-01-01

    Roč. 2, č. 3 (2005), s. 99-106 ISSN 1479-456X R&D Projects: GA ČR(CZ) GA203/00/0632 Institutional research plan: CEZ:AV0Z40400503 Keywords : total body water * deuterium isotope dilution * FA-MS * bio-impendance Subject RIV: CF - Physical ; Theoretical Chemistry

  3. SU-E-J-170: Dosimetric Consequences of Uncorrected Rotational Setup Errors During Stereotactic Body Radiation Therapy (SBRT) Treatment of Pancreatic Cancers

    Energy Technology Data Exchange (ETDEWEB)

    Di Maso, L [Chicago, IL (United States); Forbang, R Teboh; Zhang, Y; Herman, J; Lee, J [John Hopkins University, Baltimore, MD (United States)

    2015-06-15

    Purpose: To explore the dosimetric consequences of uncorrected rotational setup errors during SBRT for pancreatic cancer patients. Methods: This was a retrospective study utilizing data from ten (n=10) previously treated SBRT pancreas patients. For each original planning CT, we applied rotational transformations to derive additional CT images representative of possible rotational setup errors. This resulted in 6 different sets of rotational combinations, creating a total of 60 CT planning images. The patients’ clinical dosimetric plans were then applied to their corresponding rotated CT images. The 6 rotation sets encompassed a 3, 2 and 1-degree rotation in each rotational direction and a 3-degree in just the pitch, a 3-degree in just the yaw and a 3-degree in just the roll. After the dosimetric plan was applied to the rotated CT images, the resulting plan was then evaluated and compared with the clinical plan for tumor coverage and normal tissue sparing. Results: PTV coverage, defined here by V33 throughout all of the patients’ clinical plans, ranged from 92–98%. After an n degree rotation in each rotational direction that range decreased to 68–87%, 85–92%, and 88– 94% for n=3, 2 and 1 respectively. Normal tissue sparing defined here by the proximal stomach V15 throughout all of the patients’ clinical plans ranged from 0–8.9 cc. After an n degree rotation in each rotational direction that range increased to 0–17 cc, 0–12 cc, and 0–10 cc for n=3, 2, and 1 respectively. Conclusion: For pancreatic SBRT, small rotational setup errors in the pitch, yaw and roll direction on average caused under dosage to PTV and over dosage to proximal normal tissue. The 1-degree rotation was on average the least detrimental to the normal tissue and the coverage of the PTV. The 3-degree yaw created on average the lowest increase in volume coverage to normal tissue. This research was sponsored by the AAPM Education Council through the AAPM Education and Research

  4. Estimation of the dose distribution within, and total dose to, the body of an acutely overexposed person

    International Nuclear Information System (INIS)

    Beer, G.P. de; Feather, J.I.; Oude, A. de; Language, A.E.

    1981-01-01

    In a case of accidental overexposure of a person, it is important to obtain a reliable value of the whole body dose as well as of the dose distribution within the body. Any follow-up treatment based only on the clinical effects as and when they appear, may result in insufficient or even erroneous therapy. In this respect knowledge of total dose and its distribution within the body may be a valuable aid in deciding on the follow-up treatment, taking into account the latent nature of the clinical effects. The calculated whole body dose and its distribution within the body of a person overexposed to a 192 Ir radiography source, are compared to experimentally determined values. In both cases the calculated values prove to be of sufficient accuracy to serve as an aid in decisions on the follow-up treatment. (author)

  5. SU-E-T-522: Investigation of Underdosage of Total Body Irradiation with Bilateral Irradiation Scheme

    Energy Technology Data Exchange (ETDEWEB)

    Lin, T; Eldib, A; Hossain, M; Price, R; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2015-06-15

    Purpose: Patient in-vivo measurements report lower readings than those predicted from TMR-based treatment planning on TBI patient knees and ankles where rice was placed to fill the gap between patient’s legs. This study is to understand and correct the under dosage of Total Body Irradiation(TBI) with rice tissue equivalent bolus placement at TBI treatment patient setup. Methods: Bilateral TBI scheme was investigated with rice bags bolus placing between patient’s two legs acting as missing tissue. In-house TMR based treatment planning system was commissioned with measurements under TBI condition at 10MV, i.e. source-to-reference distance 383.4cm with 40×40cm field size with 1cm thickness Lucite. Predictions of patient specific dose points are reported at different sites with 200cGy prescription at patient umbilicus point. Solid water and rice bag phantoms are used at TBI conditions for the attenuation factor verification and CT scanned to verify the CT number and electron density. Results: We found that the rice bag bolus overall density is 11% lower than the water; however, the attenuation factor of rice bags could become 15% lower than that of water at TBI condition. This overestimate of rice bag electron density could cause the lack of lateral scatter and the lack of backscatter. This could Result in an overestimate of dose at in-vivo dosimeter measurement points with TMR-based treatment planning systems. Observations of patient specific optically stimulated luminescent dosimeters(OSLDs) were used to confirm this overestimation. Measurements of setups with increasing the rice bag filled patient leg separation were performed to demonstrate eliminating the overdose issue. Conclusion: Rice bolus has a lower electron density than water does(11%) but results in 15% lower in attenuation factor at TBI condition. This effect was observed in patient delivery with OSLD measurements and can be corrected by increasing the filling rice bolus thickness with 15% longer of

  6. SU-E-T-522: Investigation of Underdosage of Total Body Irradiation with Bilateral Irradiation Scheme

    International Nuclear Information System (INIS)

    Lin, T; Eldib, A; Hossain, M; Price, R; Ma, C

    2015-01-01

    Purpose: Patient in-vivo measurements report lower readings than those predicted from TMR-based treatment planning on TBI patient knees and ankles where rice was placed to fill the gap between patient’s legs. This study is to understand and correct the under dosage of Total Body Irradiation(TBI) with rice tissue equivalent bolus placement at TBI treatment patient setup. Methods: Bilateral TBI scheme was investigated with rice bags bolus placing between patient’s two legs acting as missing tissue. In-house TMR based treatment planning system was commissioned with measurements under TBI condition at 10MV, i.e. source-to-reference distance 383.4cm with 40×40cm field size with 1cm thickness Lucite. Predictions of patient specific dose points are reported at different sites with 200cGy prescription at patient umbilicus point. Solid water and rice bag phantoms are used at TBI conditions for the attenuation factor verification and CT scanned to verify the CT number and electron density. Results: We found that the rice bag bolus overall density is 11% lower than the water; however, the attenuation factor of rice bags could become 15% lower than that of water at TBI condition. This overestimate of rice bag electron density could cause the lack of lateral scatter and the lack of backscatter. This could Result in an overestimate of dose at in-vivo dosimeter measurement points with TMR-based treatment planning systems. Observations of patient specific optically stimulated luminescent dosimeters(OSLDs) were used to confirm this overestimation. Measurements of setups with increasing the rice bag filled patient leg separation were performed to demonstrate eliminating the overdose issue. Conclusion: Rice bolus has a lower electron density than water does(11%) but results in 15% lower in attenuation factor at TBI condition. This effect was observed in patient delivery with OSLD measurements and can be corrected by increasing the filling rice bolus thickness with 15% longer of

  7. Monitoring of total body water to examine the progress of acclimatization of runners at varying altitudes

    Directory of Open Access Journals (Sweden)

    Miroslav Semerád

    2017-11-01

    Full Text Available The purpose of our pilot study was to find out if total body water (TBW changes could objectively modify the course of adaptation during training for elite runners at different altitudes. The aim of this pilot study is to summarize the indication of the progress of acclimatization at high altitudes (1000–2700 meters above sea level during alpine conditioning. In three training camps at various altitudes the TBW of elite runners (F = 3, M = 1; n = 4; age 23 } 0.9 was monitored, in order to check the progress of acclimatization. We used BIA measurement methods (Bodystat 1500 at different high altitude running camps at the Czech Republic, Morocco and Ethiopia. Changes in TBW were used to check the progress of acclimatization. We discovered that the retention peaks of TBW corresponded with critical days (p ≤ 0.04; Cohen’s d. The highest measured increases of TBW at an altitude of 1000 m were for runner 1, 1.7 litres and for runner 2, 2.1 litres with retention peaks for both occurring on the 5th day. At an altitude of 1770 m runner 1 reached an increase of TBW of 6.3 litres, with a retention peak on the 11th day, and runner 3 had an increase of 5.1 litres with a peak on the 8th day. In the acclimatization phase we found two critical periods, from the 4th–6th day, and after the 10th–12th day. For runner 4 in altitude 2700m who completed the camp at a higher altitude, the situation is more complicated because there were fluctuations of the content of TBW in the range of 1.25 litres, with the highest depression on the 5th and then again an unsettled rise and reaching a maximum on the 12th, when she nearly returned to the initial value. Detected retention peaks reflected different levels of altitude (5th–12th days.We can conclude that the measuring of changes in TBW during camps at higher altitudes may be one of the biomarkers during acclimatization to altitude.

  8. Dose-escalated total body irradiation and autologous stem cell transplantation for refractory hematologic malignancy

    International Nuclear Information System (INIS)

    McAfee, Steven L.; Powell, Simon N.; Colby, Christine; Spitzer, Thomas R.

    2002-01-01

    Purpose: To evaluate the feasibility of dose escalation of total body irradiation (TBI) above the previously reported maximally tolerated dose, we have undertaken a Phase I-II trial of dose-escalated TBI with autologous peripheral blood stem cell transplantation (PBSCT) for chemotherapy-refractory lymphoma. Methods and Materials: Nine lymphoma patients with primary refractory disease (PRD) or in resistant relapse (RR) received dose-escalated TBI and PBSCT. The three dose levels of fractionated TBI (200 cGy twice daily) were 1,600 cGy, 1,800 cGy, and 2,000 cGy. Lung blocks were used to reduce the TBI transmission dose by 50%, and the chest wall dose was supplemented to the prescribed dose using electrons. Shielding of the kidneys was performed to keep the maximal renal dose at 1,600 cGy. Three patients, two with non-Hodgkin's lymphoma (NHL) in RR and one with PRD Hodgkin's disease, received 1,600 cGy + PBSCT, three patients (two NHL in RR, one PRD) received 1,800 cGy + PBSCT, and three patients with NHL (two in RR, one PRD) received 2,000 cGy + PBSCT. Results: Toxicities associated with this high-dose TBI regimen included reversible hepatic veno-occlusive disease in 1 patient, Grade 2 mucositis requiring narcotic analgesics in 8 patients, and neurologic toxicities consisting of a symmetrical sensory neuropathy (n=4) and Lhermitte's syndrome (n=1). Interstitial pneumonitis developed in 1 patient who received 1,800 cGy after receiving recombinant α-interferon (with exacerbation after rechallenge with interferon). Six (66%) patients achieved a response. Four (44%) patients achieved complete responses, three of which were of a duration greater than 1 year, and 2 (22%) patients achieved a partial response. One patient remains disease-free more than 5 years posttransplant. Corticosteroid-induced gastritis and postoperative infection resulted in the death of 1 patient in complete response, 429 days posttransplant. Conclusion: TBI in a dose range 1,600-2,000 cGy as

  9. Repair capacity of mouse lung after total body irradiation alone or combined with cyclophosphamide

    International Nuclear Information System (INIS)

    Safwat, Akmal; Bentzen, Soeren M.; Nielsen, Ole S.; Mahmoud, Hossam K.; Overgaard, Jens

    1996-01-01

    Purpose. Cyclophosphamide (CTX) combined with fractionated total body irradiation (TBI) is frequently used in the conditioning of patients prior to bone marrow transplantation (BMT). This study was performed to investigate the effect of CTX on the repair capacity of lung tissue after TBI in a mouse model for BMT. Materials and methods. TBI was given as a single fraction, 3 fractions in 3 days (Fx 3) or 9 fractions in 3 days (Fx 9) either alone or 24 h after a single dose of CTX. The single fraction TBI was given at either high dose rate (HDR) of 0.71 Gy/min or low dose rate (LDR) of 0.08 Gy/min. All mice were transplanted 4-6 h after the last TBI fraction. Lung damage was assessed using ventilation rate (VR) and lethality between 28 and 180 days. The repair capacity of lung tissue was estimated using the direct analysis method with the probability of reaching the end point described by a logistic formulation of the linear quadratic model. Results. The VR data confirmed the high repair capacity of lung tissue with an α/β ratio of 4.4 Gy though with a wide 95% confidence interval (CI = 0.03-10.5). Giving CTX before fractionated TBI marked reduced the doses needed to cause response in 50% of the animals. The sparing effect of using fractionated TBI was still evident in the combined CTX-TBI schedules. The estimated α/β ratio was 1.6 Gy (CI = 0.01-4.7) which is within the range of values reported after thoracic radiation only. On the other hand, the sparing effect seen in going from single fraction HDR to LDR was completely abolished when CTX was given 24 h before TBI. The same pattern was repeated when lethality between 28-180 days was used. Yet, the use of lethality to estimate lung damage in a TBI model, markedly underestimated the repair capacity. Conclusions. These results confirm the high repair capacity of lung tissue after TBI and emphasize the value of using a specific end point in testing lung damage after TBI. It also shows that there can be a negative

  10. Toxicities of total-body irradiation for pediatric bone marrow transplantation

    International Nuclear Information System (INIS)

    Chou, Rachel H.; Wong, Garrett B.; Kramer, Joel H.; Wara, Diane W.; Matthay, Katherine K.; Crittenden, Mary R.; Swift, Patrick S.; Cowan, Morton J.; Wara, William M.

    1996-01-01

    Purpose: To determine the acute and late effects, including cognitive function, of total body irradiation (TBI) and chemotherapy for bone marrow transplant (BMT) in children with immunodeficiency or hematologic disorders. Methods and Materials: At UCSF, 15 children with immunodeficiency disorders and 58 children with leukemia received chemoradiotherapy between July 1982 and November 1993 and were evaluated for toxicity. Patients with severe combined immunodeficiency disorder (SCID) received 7 Gy TBI while leukemia patients received 12 Gy TBI. Results: Eight immunodeficient patients (53%) are alive at 4 months to 11 years posttransplant. Acute toxicity was limited and treatment well tolerated. Most patients developed mild nausea and vomiting, skin rash, or erythema. Transient fever/chills, oral mucositis, and alopecia were noted in approximately 50% of patients. Seventy-three percent of patients demonstrated acute liver dysfunction, but only four (27%) developed veno-occlusive disease. All children had decreased growth velocity but normal growth hormone levels. Other endocrinologic evaluations including adrenocorticotropic hormone (ACTH), cortisol, and thyroid hormones were normal. Only one evaluable girl had delayed puberty with late onset of secondary sexual characteristics. Neuropsychological testing demonstrated an intelligence quotient (IQ) reduction between the baseline and 1 year post-BMT, with some recovery at 3 years. Only one patient developed a clinically significant cataract. Thirteen percent of patients had chronic interstitial lung disease. Four children developed exostosis. Only 1 of the 15 children developed a second malignancy (acute myelogenous leukemia) at age 5, 51 months posttransplant for SCID. For patients with leukemia, similar toxicities were observed. Twenty-nine percent disease-free survival was noted with a mean follow-up of 4.7 years. Twenty-two percent had chronic interstitial lung disease and two patients were diagnosed with cataracts

  11. Total body irradiation with an arc and a gravity-oriented compensator

    International Nuclear Information System (INIS)

    Chui, C.-S.; Fontenla, Doracy P.; Mullokandov, Edward; Kapulsky, Alex; Lo, Y.-C.; Lo, C.-J.

    1997-01-01

    Purpose: To deliver uniform dose distributions for total-body irradiation (TBI) with an arc field and a gravity-oriented compensator. This technique allows the patient to be treated lying on the floor in a small treatment room. Methods and Materials: Through the sweeping motion of the gantry, a continuous arc field can deliver a large field to a patient lying on the floor. The dose profile, however, would not be uniform if no compensator were used, due to the effects of inverse square variation of beam intensity with distance as well as the slanted depth in patient. To solve this problem, a gravity-oriented compensator made of cerrobend alloy was designed. This compensator has a cross-section of an inverted isosceles triangle, with the apex always pointing downward, due to gravity. By properly selecting the thickness of the compensator, the width of the base, and the distance between the pivots to the base, the difference in the path length through the compensator can be made just right to compensate the effects of inverse-square and slanted depth, thus producing a uniform dose profile. Results: Arc fields with a gravity-oriented compensator were used for 6, 10, 15, and 18 MV photon beams. The arc field can cover a patient with a height up to 180 cm. The field width was chosen from 32 to 40 cm at the machine isocenter. The optimal thickness of the compensator was found to be 2.5 cm, and its base was 25 cm wide. The distance from the pivot points to the flat surface of the compensator proximal to the beam ranges from 13 to 14 cm for different beam energies. The dose uniformity at a depth of 10 cm is within ±5% for all beam energies used in this study. Conclusion: Highly uniform dose profiles for TBI treatments can be delivered with an arc and a gravity-oriented compensator. The proposed technique is simple and versatile. A single compensator can be used for all energies, because the amount of compensation can be adjusted by changing the distance to the pivot and

  12. Differential effect of L3T4+ cells on recovery from total-body irradiation

    International Nuclear Information System (INIS)

    Pantel, K.; Nakeff, A.

    1990-01-01

    We have examined the importance of L3T4+ (murine equivalent to CD4+) cells for hematopoietic regulation in vivo in unperturbed mice and mice recovering from total-body irradiation (TBI) using a cytotoxic monoclonal antibody (MoAb) raised with the GK 1.5 hybridoma. Ablating L3T4+ cells in normal (unperturbed) B6D2F1 mice substantially decreased the S-phase fraction (determined by in vivo hydroxyurea suicide) of erythroid progenitor cells (erythroid colony-forming units, CFU-E) as compared to the pretreatment level (10% +/- 14.1% [day 3 following depletion] vs 79.8% +/- 15.9%, respectively) with a corresponding decrease in the marrow content of CFU-E at this time to approximately 1% of the pretreatment value. Although the S-phase fraction of CFU-GM was decreased to 2.2% +/- 3.1% 3 days after L3T4+ cell ablation from the 21.3% +/- 8.3% pretreatment value, CFU-GM cellularity showed little change over the 3 days following anti-L3T4 treatment. Anti-L3T4 MoAb treatment had little or no effect on either the S-phase fraction or the marrow content of hematopoietic stem cells (spleen colony-forming units, CFU-S) committed to myeloerythroid differentiation. Ablating L3T4+ cells prior to a single dose of 2 Gy TBI resulted in significantly reduced marrow contents of CFU-S on day 3 and granulocyte-macrophage colony-forming units (CFU-GM) on day 6 following TBI, with little or no effect on the corresponding recovery of CFU-E. The present findings provide the first in vivo evidence that L3T4+ cells are involved in: (1) maintaining the proliferative activity of CFU-E and CFU-GM in unperturbed mice and (2) supporting the restoration of CFU-S and CFU-GM following TBI-induced myelosuppression

  13. Sixteen adult patients with acute leukemia treated by chemotherapy, total body irradiation and allogeneic marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Kodera, Yoshihisa; Morishima, Yasuo; Morishita, Yoshihisa [Nagoya Univ. (Japan). Faculty of Medicine

    1984-12-01

    Since 1976, 16 adult patients with acute leukemia have been treated by chemotherapy, total body irradiation (TBI) and allogeneic bone marrow transplantation (BMT) in the medical school hospital and the satellite hospitals of Nagoya University. The first group of 10 patients were given marrow grafts at the time of leukemic relapse and the second group of six patients were given the grafts in the period of remission of their disease. For the first group (ALL/ANLL 2:8, age (median) 33, M/F 8:2), HLA-identical donor cells (25 x 10/sup 7//kg(median)) were infused after the patients were conditioned with NSC D 245382 (ACNU) or daunorubicin, cyclophosphamide (CY) and a single shot of 1000 rad of TBI. For the second group (ALL/ANLL 4:2, age (median) 20, M/F 5:1), HLA-identical donor cells (22 x 10/sup 7//kg(median)) were infused after the patients were conditioned with CY and fractionated (250 rad x 4) TBI. All the patients were isolated in a laminar air flow room (LAF) after gut and skin decontamination. Engraftment of donor cells was confirmed in 15 out of the 16 patients. Febrile periods in LAF and the days required for platelet transfusion were prolonged in the first group. All the patients in the first group died within 12-214 days after BMT because of interstitial pneumonitis (7 patients) or bacterial infection (3 patients). On the other hand, five out of six patients in the second group are alive 84-540 days after BMT. For the surviving patients, the complications of chronic graft versus host disease, viral infections, tuberculosis, hepatitis, hemorrhagic cystitis and recurrence of leukemia are now the problems. It can be stated that the patient's clinical condition at the time of BMT is one of the most essential factors for the success of BMT although the effects of other variables, such as a change in the conditioning regimens or the supportive care, must also be carefully analyzed.

  14. 28Si total body irradiation injures bone marrow hematopoietic stem cells via induction of cellular apoptosis

    Science.gov (United States)

    Chang, Jianhui; Feng, Wei; Wang, Yingying; Allen, Antiño R.; Turner, Jennifer; Stewart, Blair; Raber, Jacob; Hauer-Jensen, Martin; Zhou, Daohong; Shao, Lijian

    2017-05-01

    Long-term space mission exposes astronauts to a radiation environment with potential health hazards. High-energy charged particles (HZE), including 28Si nuclei in space, have deleterious effects on cells due to their characteristics with high linear energy transfer and dense ionization. The influence of 28Si ions contributes more than 10% to the radiation dose equivalent in the space environment. Understanding the biological effects of 28Si irradiation is important to assess the potential health hazards of long-term space missions. The hematopoietic system is highly sensitive to radiation injury and bone marrow (BM) suppression is the primary life-threatening injuries after exposure to a moderate dose of radiation. Therefore, in the present study we investigated the acute effects of low doses of 28Si irradiation on the hematopoietic system in a mouse model. Specifically, 6-month-old C57BL/6 J mice were exposed to 0.3, 0.6 and 0.9 Gy 28Si (600 MeV) total body irradiation (TBI). The effects of 28Si TBI on BM hematopoietic stem cells (HSCs) and hematopoietic progenitor cells (HPCs) were examined four weeks after the exposure. The results showed that exposure to 28Si TBI dramatically reduced the frequencies and numbers of HSCs in irradiated mice, compared to non-irradiated controls, in a radiation dose-dependent manner. In contrast, no significant changes were observed in BM HPCs regardless of radiation doses. Furthermore, irradiated HSCs exhibited a significant impairment in clonogenic ability. These acute effects of 28Si irradiation on HSCs may be attributable to radiation-induced apoptosis of HSCs, because HSCs, but not HPCs, from irradiated mice exhibited a significant increase in apoptosis in a radiation dose-dependent manner. However, exposure to low doses of 28Si did not result in an increased production of reactive oxygen species and DNA damage in HSCs and HPCs. These findings indicate that exposure to 28Si irradiation leads to acute HSC damage.

  15. An Lq-approach with generalized anisotropic weight of the weak solution of the Oseen flow around a rotating body in the whole space

    Czech Academy of Sciences Publication Activity Database

    Kračmar, S.; Krbec, Miroslav; Nečasová, Šárka; Penel, P.; Schumacher, K.

    2009-01-01

    Roč. 71, č. 12 (2009), e2940-e2957 ISSN 0362-546X R&D Projects: GA AV ČR IAA100190804 Institutional research plan: CEZ:AV0Z10190503 Keywords : littlewood-Paley theory * maximal operators * rotating body * Muckenhoupt weights * one-sided weights Subject RIV: BA - General Mathematics Impact factor: 1.487, year: 2009

  16. Total body fat, proinflammatory cytokines and insulin resistance in Indian subjects. Highlights and achievements

    International Nuclear Information System (INIS)

    Yajnik, C.S.

    2002-01-01

    Urban and migrant Indians are experiencing a rapidly escalating epidemic of diabetes and CHD. This may be related to high body fat percentage in Indians and its central distribution which have been shown to be detrimental for metabolism

  17. Chondrosarcoma arising within a radiation-induced osteochondroma several years following childhood total body irradiation: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Shuji [Kurume University Hospital, Department of Radiology, Fukuoka (Japan); Shen, Robert K. [Mayo Clinic, Department of Surgery, Rochester, MN (United States); Laack, Nadia N. [Mayo Clinic, Department of Radiation Oncology, Rochester, MN (United States); Inwards, Carrie Y. [Mayo Clinic, Department of Pathology, Rochester, MN (United States); Wenger, Doris E.; Amrami, Kimberly K. [Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2013-08-15

    Malignant degeneration arising in radiation-induced osteochondromas is extremely rare. We report a case of a 34-year-old man with a chondrosarcoma arising from an osteochondroma of the left posterior eighth rib that developed following total body irradiation received as part of the conditioning regimen prior to bone marrow transplantation at age 8. To our knowledge, this is only the fourth reported case of a chondrosarcoma arising within a radiation-induced osteochondroma and the first case occurring following childhood total body irradiation. (orig.)

  18. Chondrosarcoma arising within a radiation-induced osteochondroma several years following childhood total body irradiation: Case report

    International Nuclear Information System (INIS)

    Nagata, Shuji; Shen, Robert K.; Laack, Nadia N.; Inwards, Carrie Y.; Wenger, Doris E.; Amrami, Kimberly K.

    2013-01-01

    Malignant degeneration arising in radiation-induced osteochondromas is extremely rare. We report a case of a 34-year-old man with a chondrosarcoma arising from an osteochondroma of the left posterior eighth rib that developed following total body irradiation received as part of the conditioning regimen prior to bone marrow transplantation at age 8. To our knowledge, this is only the fourth reported case of a chondrosarcoma arising within a radiation-induced osteochondroma and the first case occurring following childhood total body irradiation. (orig.)

  19. Total body fat, abdominal fat, body fat distribution and surrogate markers for health related to adipocyte fatty acid-binding protein (FABP4) in children.

    Science.gov (United States)

    Dencker, Magnus; Danielson, Anton; Karlsson, Magnus K; Wollmer, Per; Andersen, Lars B; Thorsson, Ola

    2017-04-01

    The aim of the study was to assess possible relationships between adipocyte fatty acid-binding protein (FABP4) and total body fat (TBF), abdominal fat, body fat distribution, aerobic fitness, blood pressure, cardiac dimensions and the increase in body fat over 2 years in a community sample of children. A cross-sectional study was used in a community sample of 170 (92 boys and 78 girls) children aged 8-11 years. TBF and abdominal fat (AFM) were measured by dual-energy X-ray absorptiometry (DXA). TBF was also expressed as percentage of total body mass (BF%), and body fat distribution was calculated as AFM/TBF. Maximal oxygen uptake (VO2PEAK) was assessed by indirect calorimetry during a maximal exercise test and scaled to body mass. Systolic and diastolic blood pressure (SBP and DBP) and pulse pressure (PP) were measured. Echocardiography was performed. Left atrial (LA) size was measured, and left ventricular mass (LVM) was calculated. A follow-up DXA scan was available in 152 children (84 boys and 68 girls). Frozen serum samples were analyzed for FABP4. Partial correlations, with adjustment for sex, between FABP4 vs. ln TBF, ln BF%, ln AFM, AFM/TBF and VO2PEAK were (r=0.69, 0.68, 0.69, 0.49 and -0.39, pfat or change in fat distribution were not correlated.) Conclusions: Findings from this community-based cohort of young children show that increased body fat and abdominal fat, more abdominal body fat distribution, low fitness, more LVM and increased LA, increased SBP and PP were all associated with increased levels of FABP4. Increase in TBF and abdominal fat over 2 years were also associated with increased levels of FABP4.

  20. The relationship of total body composition with bone mineral density in postmenopausal women with type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Vadim Valer'evich Klimontov

    2015-03-01

    Full Text Available AimTo determine the relationship between bone mineral density (BMD and total body composition in postmenopausal women with type 2 diabetes.Materials and MethodsThe study included 78 women, from 50 to 70 years of age (median 63 years. Twenty women had normal body mass index (BMI, 29 ones were overweight and 29 had obesity. The body composition and BMD was studied by dual-energy X-ray absorptiometry.ResultsWomen with normal BMD had higher BMI, total and truncal fat mass, as well lean mass as compared to women with osteoporosis and osteopenia (all p <0.05. Patients with osteoporosis had a lower fat mass at the hips, compared with those with normal BMD. Total and truncal fat mass, as well as lean mass were positively correlated with BMD in the lumbar spine and proximal femur, femoral neck and radius. In multivariate regression analysis fat mass was an independent predictor for total BMD, after adjusting for age, BMI, duration of menopause, HbA1c, glomerular filtration rate and other total body composition parameters.ConclusionsIn postmenopausal type 2 diabetic women BMI and fat mass is associated positively with BMD.

  1. The use of bioelectrical impedance analysis to estimate total body water in young children with cerebral palsy.

    Science.gov (United States)

    Bell, Kristie L; Boyd, Roslyn N; Walker, Jacqueline L; Stevenson, Richard D; Davies, Peter S W

    2013-08-01

    Body composition assessment is an essential component of nutritional evaluation in children with cerebral palsy. This study aimed to validate bioelectrical impedance to estimate total body water in young children with cerebral palsy and determine best electrode placement in unilateral impairment. 55 young children with cerebral palsy across all functional ability levels were included. Height/length was measured or estimated from knee height. Total body water was estimated using a Bodystat 1500MDD and three equations, and measured using the gold standard, deuterium dilution technique. Comparisons were made using Bland Altman analysis. For children with bilateral impairment, the Fjeld equation estimated total body water with the least bias (limits of agreement): 0.0 L (-1.4 L to 1.5 L); the Pencharz equation produced the greatest: 2.7 L (0.6 L-4.8 L). For children with unilateral impairment, differences between measured and estimated total body water were lowest on the unimpaired side using the Fjeld equation 0.1 L (-1.5 L to 1.6 L)) and greatest for the Pencharz equation. The ability of bioelectrical impedance to estimate total body water depends on the equation chosen. The Fjeld equation was the most accurate for the group, however, individual results varied by up to 18%. A population specific equation was developed and may enhance the accuracy of estimates. Australian New Zealand Clinical Trials Registry (ANZCTR) number: ACTRN12611000616976. Copyright © 2012 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  2. Influence of physical activity on the metabolism and the total body content of sodium and potassium in the rat

    International Nuclear Information System (INIS)

    Yeh, J.K.; Yasumura, A.; Aloia, J.F.

    1986-01-01

    The purpose of this study was to investigate the effect of exercise (EX) and immobilization (IMB) on the absorption, excretion and total body content of sodium (TBNa) and potassium (TBK). Female Sprague Dawley rats 5 weeks old were divided into four groups: EX; Control (CON); EX with pair feeding to the level equal to the CON (EX-P); IMB by sciatica denervation. The nutritional balance study data was taken 5 weeks into the experimental period and the animals were sacrificed after 5 additional weeks of experimentation. The carcasses were kept frozen and used for total body composition by neutron activation. The results of the total body composition show that EX resulted in an increase, IMB resulted in a decrease, of the TBNa and TBK. There was no significant difference in TBNa of TBK, between the EX and the EX-P groups even though, the food intake was higher in the EX group. The results of the nutritional balance study confirmed the results of the total body composition

  3. Effects of zilpaterol hydrochloride on methane production, total body oxygen consumption, and blood metabolites in finishing beef steers

    Science.gov (United States)

    An indirect calorimetry experiment was conducted to determine the effects of feeding zilpaterol hydrochloride (ZH) for 20 d on total body oxygen consumption, respiratory quotient, methane production, and blood metabolites in finishing beef steers. Sixteen Angus steers (initial BW = 555 ± 12.7 kg) w...

  4. Comparative seric TGF(β1, β2) levels and platelets count response in total body irradiated baboons

    International Nuclear Information System (INIS)

    Mestries, J.C.; Veyret, J.; Agay, D.; Van Uye, A.; Caterini, R.; Herodin, F.; Mathieu, J.; Chancerelle, Y.

    1994-01-01

    Total body irradiation associated or not with r-hIL-6 treatment a relation between TGF-β1 and TGF-β2 blood levels and platelets count. During radio-induced thrombocytopenia, by decreasing its ability to inhibit proliferation of stem cells and megakaryocytopoiesis, the TGF-β falling induced a favorable condition for hematopoietic recovery. (author)

  5. Influence of radioprotectors on total body weight evolution and on oxygen consumption in lethal dose irradiated animals. (Preliminary study)

    International Nuclear Information System (INIS)

    Fatome, M.; Martine, G.; Bargy, E.; Andrieu, L.

    Comparison of total body weight evolution and oxygen consumption in lethal dose irradiated animals, protected by various well known radioprotective substances, isolated or in mixture, with evolution and consumption of non protected animals irradiated at the same dose and with these of check animals [fr

  6. TNF, IL-1 and IL-6 in circulating blood after total-body and localized irradiation in rats

    NARCIS (Netherlands)

    Haveman, J.; Geerdink, A. G.; Rodermond, H. M.

    1998-01-01

    The levels of TNF, IL-1 and IL-6 in circulating blood of female WAG/Rij rats were assessed both after total-body irradiation (TBI) and localized irradiation of the right hind leg. The results show that enhanced levels of IL-1 in the circulation reflect a stress situation presumably resulting from

  7. Total body composition measurements using in vivo neutron activation at the University of Washington

    International Nuclear Information System (INIS)

    Lewellen, T.L.

    1986-01-01

    The University of Washington Division of Nuclear Medicine has been using in vivo irradiation to study whole body calcium since 1969. Over 350 patients have been studied and currently five patients per week are being measured in support of research programs on bone wasting disease. (author)

  8. Monitoring total-body inflammation and damage in joints and entheses

    DEFF Research Database (Denmark)

    Axelsen, M. B.; Eshed, I.; Østergaard, M.

    2017-01-01

    Objective: To investigate changes in whole-body magnetic resonance imaging (WBMRI) inflammatory and structural lesions in most joints and entheses in patients with rheumatoid arthritis (RA) treated with adalimumab. Methods: WBMRI was obtained at weeks 0, 6, 16, and 52 in a 52 week follow-up study...

  9. Hematologic status of mice submitted to sublethal total body irradiation with mixed neutron-gamma radiation

    International Nuclear Information System (INIS)

    Herodin, F.; Court, L.

    1989-01-01

    The hematologic status of mice exposed to sublethal whole body irradiation with mixed neutron-gamma radiation (mainly neutrons) is studied. A slight decrease of the blood cell count is still observed below 1 Gy. The recovery of bone marrow granulocyte-macrophage progenitors seems to require more time than after pure gamma irradiation [fr

  10. Body surface posture evaluation: construction, validation and protocol of the SPGAP system (Posture evaluation rotating platform system).

    Science.gov (United States)

    Schwertner, Debora Soccal; Oliveira, Raul; Mazo, Giovana Zarpellon; Gioda, Fabiane Rosa; Kelber, Christian Roberto; Swarowsky, Alessandra

    2016-05-04

    Several posture evaluation devices have been used to detect deviations of the vertebral column. However it has been observed that the instruments present measurement errors related to the equipment, environment or measurement protocol. This study aimed to build, validate, analyze the reliability and describe a measurement protocol for the use of the Posture Evaluation Rotating Platform System (SPGAP, Brazilian abbreviation). The posture evaluation system comprises a Posture Evaluation Rotating Platform, video camera, calibration support and measurement software. Two pilot studies were carried out with 102 elderly individuals (average age 69 years old, SD = ±7.3) to establish a protocol for SPGAP, controlling the measurement errors related to the environment, equipment and the person under evaluation. Content validation was completed with input from judges with expertise in posture measurement. The variation coefficient method was used to validate the measurement by the instrument of an object with known dimensions. Finally, reliability was established using repeated measurements of the known object. Expert content judges gave the system excellent ratings for content validity (mean 9.4 out of 10; SD 1.13). The measurement of an object with known dimensions indicated excellent validity (all measurement errors reality. To verify the images of objects with known dimensions the values for the width and height were, respectively, CV 0.88 (width) and 2.33 (height), SD 0.22 (width) and 0.35 (height), minimum and maximum values 24.83-25.2 (width) and 14.56 - 15.75 (height). In the analysis of different images (similar) of an individual, greater discrepancies were observed in the values found. The cervical index, for example, presented minimum and maximum values of 15.38 and 37.5, a coefficient of variation of 0.29 and a standard deviation of 6.78. The SPGAP was shown to be a valid and reliable instrument for the quantitative analysis of body posture with applicability and

  11. Empirical Estimation of Total Nitrogen and Total Phosphorus Concentration of Urban Water Bodies in China Using High Resolution IKONOS Multispectral Imagery

    Directory of Open Access Journals (Sweden)

    Jiaming Liu

    2015-11-01

    Full Text Available Measuring total nitrogen (TN and total phosphorus (TP is important in managing heavy polluted urban waters in China. This study uses high spatial resolution IKONOS imagery with four multispectral bands, which roughly correspond to Landsat/TM bands 1–4, to determine TN and TP in small urban rivers and lakes in China. By using Lake Cihu and the lower reaches of Wen-Rui Tang (WRT River as examples, this paper develops both multiple linear regressions (MLR and artificial neural network (ANN models to estimate TN and TP concentrations from high spatial resolution remote sensing imagery and in situ water samples collected concurrently with overpassing satellite. The measured and estimated values of both MLR and ANN models are in good agreement (R2 > 0.85 and RMSE < 2.50. The empirical equations selected by MLR are more straightforward, whereas the estimated accuracy using ANN model is better (R2 > 0.86 and RMSE < 0.89. Results validate the potential of using high resolution IKONOS multispectral imagery to study the chemical states of small-sized urban water bodies. The spatial distribution maps of TN and TP concentrations generated by the ANN model can inform the decision makers of variations in water quality in Lake Cihu and lower reaches of WRT River. The approaches and equations developed in this study could be applied to other urban water bodies for water quality monitoring.

  12. The total body length and body weight examination among gabus Sentani fish population, Oxyeleotris heterodon, Weber 1907 (Pisces: Eleotridae) of Sentani lake, Papua, Indonesia

    Science.gov (United States)

    Sriyani, E. D.; Abinawanto, Bowolaksono, A.

    2017-07-01

    The gabus Sentani fish lived in the Sentani Lake, Papua, since million years ago. Nowadays, the population of those species is getting extinct because of the overexploitation, whereas the culture effort of this species has not been developed, yet. The purpose of the study was to examine the total body length and body weight collected from some villages surrounding Sentani Lake such as Ifar village, Sosiri village, and Putali village. The body weight average of gabus fish from Ifar village, Sosiri village, and Putali village were 373.53 g, 426.86 g, and 118.34 g respectively. While the total body length average of gabus Sentani fish from Ifar village, Sosiri village, and Putali village were 279.30 mm, 223.30 mm and 222.06 mm, respectively. The growth model was W = 0.021067L3.086 with R2 value was 35.8 %, and r value was 0.598. Gabus Sentani fish, Oxyeleotris heterodon (Weber 1907) exhibited positive allometric (b > 3).

  13. A Common Allele in FGF21 Associated with Sugar Intake Is Associated with Body Shape, Lower Total Body-Fat Percentage, and Higher Blood Pressure

    Directory of Open Access Journals (Sweden)

    Timothy M. Frayling

    2018-04-01

    Full Text Available Summary: Fibroblast growth factor 21 (FGF21 is a hormone that has insulin-sensitizing properties. Some trials of FGF21 analogs show weight loss and lipid-lowering effects. Recent studies have shown that a common allele in the FGF21 gene alters the balance of macronutrients consumed, but there was little evidence of an effect on metabolic traits. We studied a common FGF21 allele (A:rs838133 in 451,099 people from the UK Biobank study, aiming to use the human allele to inform potential adverse and beneficial effects of targeting FGF21. We replicated the association between the A allele and higher percentage carbohydrate intake. We then showed that this allele is more strongly associated with higher blood pressure and waist-hip ratio, despite an association with lower total body-fat percentage, than it is with BMI or type 2 diabetes. These human phenotypes of variation in the FGF21 gene will inform research into FGF21’s mechanisms and therapeutic potential. : Drugs targeting the hormone FGF21 may have beneficial health effects. Variations in human DNA in the FGF21 gene provide an indication of what those effects may be. Here, we show that variation in the FGF21 gene is associated with higher blood pressure and altered body shape, despite lower total body-fat percentage. Keywords: FGF21, BMI, waist-hip ratio, blood pressure, body fat, allele, genetic variant, UK Biobank

  14. The estimation of total body fat by inelastic neutron scattering - a geometrical feasibility study

    International Nuclear Information System (INIS)

    Lizos, F.; Kotzasarlidoou, M.; Makridou, A.; Giannopoulou, K.

    2012-01-01

    A rough quantitative representation of the basic elements in a human body is shown. It deals with a hypothetical, normal adult weighting 70 kg. It is possible to measure two basic quantities, the FFM, standing for Fat Free Mass and the FM, standing for Fat Mass. The present simulation deals with the most important aspect of the estimation of storage fat in the human body and in order to accomplish such a task, it is considered a representation of the human body, containing a uniform distribution of triacylglycerols, in a shape of cylindrical phantom. The whole process is analyzed and simulated by a geometrical model and with the aid of a computer program which takes into consideration the different attenuation for neutrons and photons, the amount of gamma radiation reaching the detector is also calculated. The net result is the determination of sensitivity for a particular set-up and by relating the out coming data to the amount of carbon; the quantity of fat is estimated. In addition, the non-uniformity is calculated, from the computer programs expressing the consistency of the system. In order to determine the storage fat, a simulation model that will enable to represent the detection of the carbon atoms in triacylglycerols was built

  15. Fractionated total body irradiation and autologous bone marrow transplantation in dogs: Hemopoietic recovery after various marrow cell doses

    International Nuclear Information System (INIS)

    Bodenburger, U.; Kolb, H.J.; Thierfelder, S.; Netzel, B.; Schaeffer, E.; Kolb, H.

    1980-01-01

    Hemopoietic recovery was studied in dogs given 2400 R fractionated total body irradiation within one week and graded doses of cryopreserved autologous bone marrow. Complete hemopoietic recovery including histology was observed after this dose and sufficient doses of marrow cells. Doses of more than 5.5 x 10 7 mononuclear marrow cells/kg body weight were sufficient for complete recovery in all dogs, 1.5 to 5.5 x 10 7 cells/kg were effective in some of the dogs and less than 1.5 x 10 7 cells/kg were insufficient for complete recovery. Similarly, more than 30000 CFUsub(c)/kg body weight were required for hemopoietic recovery. The optimal marrow cell dose which has been defined as the minimal dose required for the earliest possible recovery of leukocyte and platelet counts was 7-8 x 10 7 mononuclear marrow cells/kg body weight. It has been concluded that fractionated total body irradiation with 2400 R dose not require greater doses of marrow cells for hemopoietic reconstitution than lower single doses and that the hemopoietic microenvironment is not persistently disturbed after this dose. (author)

  16. Thermodynamics of the living organisms. Allometric relationship between the total metabolic energy, chemical energy and body temperature in mammals

    Science.gov (United States)

    Atanasov, Atanas Todorov

    2017-11-01

    The study present relationship between the total metabolic energy (ETME(c), J) derived as a function of body chemical energy (Gchem, J) and absolute temperature (Tb, K) in mammals: ETME(c) =Gchem (Tb/Tn). In formula the temperature Tn =2.73K appears normalization temperature. The calculated total metabolic energy ETME(c) differs negligible from the total metabolic energy ETME(J), received as a product between the basal metabolic rate (Pm, J/s) and the lifespan (Tls, s) of mammals: ETME = Pm×Tls. The physical nature and biological mean of the normalization temperature (Tn, K) is unclear. It is made the hypothesis that the kTn energy (where k= 1.3806×10-23 J/K -Boltzmann constant) presents energy of excitation states (modes) in biomolecules and body structures that could be in equilibrium with chemical energy accumulated in body. This means that the accumulated chemical energy allows trough all body molecules and structures to propagate excitations states with kTn energy with wavelength in the rage of width of biological membranes. The accumulated in biomolecules chemical energy maintains spread of the excited states through biomolecules without loss of energy.

  17. Report on research and development achievements in fiscal 1980 in Sunshine Project. Development of a total flow electric power plant(Two-phase rotation inflator); 1980 nendo total flow hatsuden plant no kaihatsu seika hokokusho. Niso kaiten bochoki

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1981-03-01

    Out of the development of a total flow power plant in the Sunshine Project, this paper describes a two-phase rotatry inflator. It reports the achievements in fiscal 1980. It is intended to utilize effectively the energy of gas-liquid two-phase fluid (containing a great amount of hot water) often seen in geothermal resources in Japan. Therefore, development is considered on a two-phase rotary inflator as a total flow power generation technology to inflate the gas-liquid fluid as it is without performing separation thereof, and convert it to an external work to draw out output. The inflator is a volume type rotary engine, which has the highest efficiency theoretically, but has not been put into practical use worldwide. Based on the result obtained in the previous fiscal year, development is made on a most suitable seal to be applied to circumferential seal of an external rotor, apex seal, and intake port seal. A rotary inflation performance testing machine is fabricated to study inflation of the gas-liquid two-phase fluid. Setting the engine efficiency of 60% or higher as the target, detailed design, fabrication and assembly shall be completed on two-phase rotation inflators of volume type and self-rotation type of 300 kW class. (NEDO)

  18. Numerical computation of gravitational field of general extended body and its application to rotation curve study of galaxies

    Science.gov (United States)

    Fukushima, Toshio

    2017-06-01

    Reviewed are recently developed methods of the numerical integration of the gravitational field of general two- or three-dimensional bodies with arbitrary shape and mass density distribution: (i) an axisymmetric infinitely-thin disc (Fukushima 2016a, MNRAS, 456, 3702), (ii) a general infinitely-thin plate (Fukushima 2016b, MNRAS, 459, 3825), (iii) a plane-symmetric and axisymmetric ring-like object (Fukushima 2016c, AJ, 152, 35), (iv) an axisymmetric thick disc (Fukushima 2016d, MNRAS, 462, 2138), and (v) a general three-dimensional body (Fukushima 2016e, MNRAS, 463, 1500). The key techniques employed are (a) the split quadrature method using the double exponential rule (Takahashi and Mori, 1973, Numer. Math., 21, 206), (b) the precise and fast computation of complete elliptic integrals (Fukushima 2015, J. Comp. Appl. Math., 282, 71), (c) Ridder's algorithm of numerical differentiaion (Ridder 1982, Adv. Eng. Softw., 4, 75), (d) the recursive computation of the zonal toroidal harmonics, and (e) the integration variable transformation to the local spherical polar coordinates. These devices succesfully regularize the Newton kernel in the integrands so as to provide accurate integral values. For example, the general 3D potential is regularly integrated as Φ (\\vec{x}) = - G \\int_0^∞ ( \\int_{-1}^1 ( \\int_0^{2π} ρ (\\vec{x}+\\vec{q}) dψ ) dγ ) q dq, where \\vec{q} = q (√{1-γ^2} cos ψ, √{1-γ^2} sin ψ, γ), is the relative position vector referred to \\vec{x}, the position vector at which the potential is evaluated. As a result, the new methods can compute the potential and acceleration vector very accurately. In fact, the axisymmetric integration reproduces the Miyamoto-Nagai potential with 14 correct digits. The developed methods are applied to the gravitational field study of galaxies and protoplanetary discs. Among them, the investigation on the rotation curve of M33 supports a disc-like structure of the dark matter with a double-power-law surface

  19. Absolute quantitative total-body small-animal SPECT with focusing pinholes

    International Nuclear Information System (INIS)

    Wu, Chao; Have, Frans van der; Vastenhouw, Brendan; Beekman, Freek J.; Dierckx, Rudi A.J.O.; Paans, Anne M.J.

    2010-01-01

    In pinhole SPECT, attenuation of the photon flux on trajectories between source and pinholes affects quantitative accuracy of reconstructed images. Previously we introduced iterative methods that compensate for image degrading effects of detector and pinhole blurring, pinhole sensitivity and scatter for multi-pinhole SPECT. The aim of this paper is (1) to investigate the accuracy of the Chang algorithm in rodents and (2) to present a practical Chang-based method using body outline contours obtained with optical cameras. Here we develop and experimentally validate a practical method for attenuation correction based on a Chang first-order method. This approach has the advantage that it is employed after, and therefore independently from, iterative reconstruction. Therefore, no new system matrix has to be calculated for each specific animal. Experiments with phantoms and animals were performed with a high-resolution focusing multi-pinhole SPECT system (U-SPECT-II, MILabs, The Netherlands). This SPECT system provides three additional optical camera images of the animal for each SPECT scan from which the animal contour can be estimated. Phantom experiments demonstrated that an average quantification error of -18.7% was reduced to -1.7% when both window-based scatter correction and Chang correction based on the body outline from optical images were applied. Without scatter and attenuation correction, quantification errors in a sacrificed rat containing sources with known activity ranged from -23.6 to -9.3%. These errors were reduced to values between -6.3 and +4.3% (with an average magnitude of 2.1%) after applying scatter and Chang attenuation correction. We conclude that the modified Chang correction based on body contour combined with window-based scatter correction is a practical method for obtaining small-animal SPECT images with high quantitative accuracy. (orig.)

  20. Divergence of the total cross section for three body rearrangement collisions with coulomb interactions

    Science.gov (United States)

    Omidvar, K.

    1972-01-01

    Three charged particles 1, 2, 3 collide according to the reaction 1+(2+3) yields (1+3)+2, where (2+3) and (1+3) are hydrogenlike bound states. It is shown when (1+3) is in a highly excited state n, due to the repulsive potential, the cross section in the first Born approximation behaves as 1/n which makes the total cross section to diverge like ln n. The total cross sections in the higher orders of the Born approximation are similarly divergent logarithmically.

  1. Long-Term Effects of Stem Cells on Total-Body Irradiated Mice

    Science.gov (United States)

    Vyalkina, M. V.; Alchinova, I. B.; Yakovenko, E. N.; Medvedeva, Yu S.; Saburina, I. N.; Karganov, M. Yu

    2017-01-01

    C57Bl/6 mice were exposed to γ-radiation in a sublethal dose of 7.5 Gy. In 3 hours injection 106/mouse of bone marrow multipotent mesenchymal stromal cells stem cells intravenously to experimental group was done. Methods used: body weight measurement, open field behavior, subfraction composition of blood serum (laser correlation spectroscopy, LCS), histological examination of the spleen, liver, and pancreas, count of T and B cells, white blood formula. After 1.5 and 3 months the general trend towards intermediate position of the parameters observed in the experimental between those in intact and irradiated controls attests to partial protective/restorative effects of the injected cells.

  2. Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy X-ray absorptiometry during prolonged weight loss

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Højgaard, L

    1996-01-01

    A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK). These measu...

  3. Self-motion perception and vestibulo-ocular reflex during whole body yaw rotation in standing subjects: the role of head position and neck proprioception.

    Science.gov (United States)

    Panichi, Roberto; Botti, Fabio Massimo; Ferraresi, Aldo; Faralli, Mario; Kyriakareli, Artemis; Schieppati, Marco; Pettorossi, Vito Enrico

    2011-04-01

    Self-motion perception and vestibulo-ocular reflex (VOR) were studied during whole body yaw rotation in the dark at different static head positions. Rotations consisted of four cycles of symmetric sinusoidal and asymmetric oscillations. Self-motion perception was evaluated by measuring the ability of subjects to manually track a static remembered target. VOR was recorded separately and the slow phase eye position (SPEP) was computed. Three different head static yaw deviations (active and passive) relative to the trunk (0°, 45° to right and 45° to left) were examined. Active head deviations had a significant effect during asymmetric oscillation: the movement perception was enhanced when the head was kept turned toward the side of body rotation and decreased in the opposite direction. Conversely, passive head deviations had no effect on movement perception. Further, vibration (100 Hz) of the neck muscles splenius capitis and sternocleidomastoideus remarkably influenced perceived rotation during asymmetric oscillation. On the other hand, SPEP of VOR was modulated by active head deviation, but was not influenced by neck muscle vibration. Through its effects on motion perception and reflex gain, head position improved gaze stability and enhanced self-motion perception in the direction of the head deviation. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. The relationships among total body fat, bone mineral content and bone marrow adipose tissue in early-pubertal girls.

    Science.gov (United States)

    L Newton, Anna; J Hanks, Lynae; Davis, Michelle; Casazza, Krista

    2013-01-01

    Investigation of the physiologic relevance of bone marrow adipose tissue (BMAT) during growth may promote understanding of the bone-fat axis and confluence with metabolic factors. The objective of this pilot investigation was two-fold: (1) to evaluate the relationships among total body fat, bone mineral content (BMC) and femoral BMAT during childhood and underlying metabolic determinants and (2) to determine if the relationships differ by race. Participants included white and non-Hispanic black girls (n=59) ages 4-10 years. Femoral BMAT volume was measured by magnetic resonance imaging, BMC and body fat by dual-energy X-ray absorptiometry. Metabolic parameters were assessed in the fasted state. Total fat and BMC were positively associated with BMAT; however, simultaneous inclusion of BMC and body fat in the statistical model attenuated the association between BMC and BMAT. Differences in BMAT volume were observed, non-Hispanic black girls exhibiting marginally greater BMAT at age eight (P=0.05) and white girls exhibiting greater BMAT at age ten (PBMAT and leptin (P=0.02) and adiponectin (P=0.002) in white girls while BMAT and insulin were inversely related in non-Hispanic black girls (P=0.008). Our findings revealed a positive relationship between BMAT, body fat and BMC, although body fat, respective to leptin, contributed partly to the relationship between BMAT and BMC. Despite large differences in total fat between non-Hispanic black and white, the relationship between BMAT and BMC was similar to white girls. However, this relationship appeared to be impacted through different mechanisms according to race.

  5. The role of total body irradiation in preparation for bone marrow transplantation in acute leukaemia. A review

    International Nuclear Information System (INIS)

    Zwaan, F.E.

    1979-01-01

    From extrapolation obtained from animal studies and radiation accidents, it is assumed that for man the LD 50 (30) will be between 300-500 rads total body irradiation (TBI) and the LD 100 at least 600 rads TBI. A dose of 1000 rads TBI is generally used in man for conditioning for bone marrow transplantation. In acute leukemia, total body irradiation is usually associated with cytoreductive chemotherapy. In Seattle 110 patients underwent bone marrow transplantation for acute leukemia in relapse. 15 patients became long term survivors. The main cause of failure were GVH, interstitial pneumonitis and leukemic relapse. New attempts are being made to improve the results: (1) better cytoreductive therapy preceding transplantation, (2) bone marrow transplantation during remission of the disease, (3) prevention of interstitial pneumonitis by modifications of the TBI technique

  6. Simultaneous measurement of milk intake and total energy expenditure in mixed-fed infants: Methodological approach and prediction of total body water

    International Nuclear Information System (INIS)

    Wells, J.C.K.; Davies, P.S.W.; Coward, W.A.

    2000-01-01

    Evaluation of the energy metabolism that underlies the new WHO breast-fed growth reference requires simultaneous measurements of milk volume intake (MVI) and total energy expenditure (TEE) by stable isotope methodologies. In young infants, such data is collected without difficulty using the dose-to-the-infant method. In older infants, where breast-milk is supplemented with non-milk foods, MVI must be measured by dosing the mother instead of the infant. This procedure would interfere with a simple measurement of infant TEE using the standard dose-to-the-infant method. Theoretically, this difficulty can be resolved by dosing the mother with deuterium and the infant with 18-oxygen, and using curve-peeling methods to calculate the infant deuterium kinetics. We propose to ascertain whether such an approach is viable in practice, such that MVI, TEE and body composition could all be measured simultaneously in mixed-fed infants. Where MVI in older infants is measured on its own, there is a need to predict infant body water in order to estimate the deuterium dilution space. Using a database of 234 infants aged 1.5 to 12 months, we provide new predictive equations by which such values may be obtained. (author)

  7. Total body irradiation for installment of arylsulfatase B activity in a cat by bone marrow transplantation

    International Nuclear Information System (INIS)

    Macy, D.W.; Gillette, E.L.; Gasper, P.W.; Thrall, M.A.; Wenger, D.A.; Kessell, M.L.; Hoover, E.A.

    1984-01-01

    Mucopolysaccharidosis VI is an inherited, metabolic defect in which a deficiency of arylsulfatase B, results in accumulation of glycosaminoglycans (GAG) in lysosomes. Arylsulfatase B activity was installed in an affected 2 year old siamese cat with no arylsulfatase B activity, excess urinary GAG, Alder-Reilly bodies in neutrophils, facial dysmorphia, corneal clouding, multiple epiphyseal dysplasia, and hind limb paresis. Following grafting of bone marrow from an immunologically nonreactive, female sibling with normal arylsulfatase B activity, increased arylsulfatase B activity and urinary excretion of hexuronic acid decreased by 19 days post transplantation. There were no metachromatic inclusions in circulating neutrophils, which were phenotypically female. The cat now has competent trilineage hematopoiesis, resolution of the facial dysmorphia, no corneal clouding, and improved movement of the head, neck, and mandible. The technique, sequence of hematologic recovery, and evidence of engraftment, are discussed. This may be a model for correction of mucopolysaccharidosis VI in man

  8. Dosimetric methods and results of measurement for total body electron irradiation

    International Nuclear Information System (INIS)

    Feng Ningyuan; Yu Geng; Yu Zihao

    1987-01-01

    A modified 'STANFORD TSEI TECHNIQUE' e.g. dual angled gantry, 6 turntable angles and 12 fields was developed on PHILIPS SL 75-20 linear accelerator to treat mycosis fungoides. A plastic scatter screen, 5 mm in thickness was used to reduce the primary electron energy to 4 MeV in order to control treatment depth (d 80 approx.= 1.2 cm) and skin dose up to 89%. The X-ray contamination was at an acceptable level of 2%. This measurement which involved multiple dosimetric methods, showed that the distance between the scattor screen and the patient, within 10-30 cm, had no influence on PDD and the dose distribution on the body surface was reasonably homogeneous, but strongly dependent on the anatomic positions. For those sites which were located in the electron beam shadows, boosting irradiation might be necessary. The preliminary clinical trials indicated that this technique is valid and feasible

  9. Long-Term Effects of Stem Cells on Total-Body Irradiated Mice

    International Nuclear Information System (INIS)

    Vyalkina, M V; Alchinova, I B; Yakovenko, E N; Medvedeva, Yu S; Saburina, I N; Karganov, M Yu

    2017-01-01

    C57Bl/6 mice were exposed to γ-radiation in a sublethal dose of 7.5 Gy. In 3 hours injection 10 6 /mouse of bone marrow multipotent mesenchymal stromal cells stem cells intravenously to experimental group was done. Methods used: body weight measurement, open field behavior, subfraction composition of blood serum (laser correlation spectroscopy, LCS), histological examination of the spleen, liver, and pancreas, count of T and B cells, white blood formula. After 1.5 and 3 months the general trend towards intermediate position of the parameters observed in the experimental between those in intact and irradiated controls attests to partial protective/restorative effects of the injected cells. (paper)

  10. The indication and the point at issue in total body irradiation (TBI)

    International Nuclear Information System (INIS)

    Kikuchi, Yuzo; Nishino, Shigeo.

    1992-01-01

    The role of radiation in the cause of interstitial pneumonitis (IP) was analysed here. Also optimal dose fractionation was discussed about total absorbed lung dose, dose rate and fractionation in spect of IP. After all optimal time schedule was recommended 3, 4 and 6 fraction of ≤ 4 Gy of fraction size using conventional and hyperfractionated irradiation. In the end the present condition and the point at issue in the irradiation of blood for prevention GVHD were discussed. (author)

  11. Prospective neurodevelopmental studies of two children treated with total body irradiation and bone marrow transplantation for acute leukemia in infancy

    International Nuclear Information System (INIS)

    Kaleita, T.; Tesler, A.; Feig, S.A.

    1987-01-01

    Five-year neurodevelopmental studies of two infants with acute leukemia are presented. Both patients underwent bone marrow transplantation (BMT) after conditioning with cyclophosphamide and total body irradiation (TBI). Neither patient was treated with intrathecal chemotherapy. Their outcome is remarkable for normal development of intelligence, language, perception, and motor coordination. These results suggest that TBI and BMT should be considered in future therapeutic studies of infants with acute leukemia, who are at great risk for failure of conventional therapy

  12. The relationships among total body fat, bone mineral content and bone marrow adipose tissue in early-pubertal girls

    OpenAIRE

    L Newton, Anna; J Hanks, Lynae; Davis, Michelle; Casazza, Krista

    2013-01-01

    Investigation of the physiologic relevance of bone marrow adipose tissue (BMAT) during growth may promote understanding of the bone-fat axis and confluence with metabolic factors. The objective of this pilot investigation was two-fold: (1) to evaluate the relationships among total body fat, bone mineral content (BMC) and femoral BMAT during childhood and underlying metabolic determinants and (2) to determine if the relationships differ by race. Participants included white and non-Hispanic bla...

  13. Linearized stationary incompressible flow around rotating and translating bodies: Asymptotic profile of the velocity gradient and decay estimate of the second derivatives of the velocity

    Czech Academy of Sciences Publication Activity Database

    Deuring, P.; Kračmar, S.; Nečasová, Šárka

    2012-01-01

    Roč. 252, č. 1 (2012), s. 459-476 ISSN 0022-0396 R&D Projects: GA AV ČR IAA100190804; GA ČR(CZ) GAP201/11/1304 Institutional research plan: CEZ:AV0Z10190503 Keywords : viscous incompressible flow * rotating body * rundamental solution * decay * asymptotic profile * Navier-Stokes system Subject RIV: BA - General Mathematics Impact factor: 1.480, year: 2012 http://www.sciencedirect.com/science/article/pii/S0022039611003573

  14. Preservation of the articular capsule and short lateral rotator in direct anterior approach to total hip arthroplasty.

    Science.gov (United States)

    Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko; Morohashi, Itaru

    2018-03-09

    In total hip arthroplasty via a direct anterior approach, the femur must be elevated at the time of femoral implant placement. For adequate elevation, division of the posterior soft tissues is necessary. However, if we damage and separate the posterior muscle tissue, we lose the benefits of the intermuscular approach. Furthermore, damage to the posterior soft tissue can result in posterior dislocation. We investigate that protecting the posterior soft tissue increases the joint stability in the early postoperative period and results in a lower dislocation rate. We evaluated muscle strength recovery by measuring the maximum width of the internal obturator muscle on CT images (GE-Healthcare Discovery CT 750HD). We compared the maximum width of the muscle belly preoperatively versus 10 days and 6 months postoperatively. As clinical evaluations, we also investigated the range of motion of the hip joint, hip joint function based on the Japanese Orthopaedic Association hip score (JOA score), and the dislocation rate 6 months after surgery. The width of the internal obturator muscle increased significantly from 15.1 ± 3.1 mm before surgery to 16.4 ± 2.8 mm 6 months after surgery. The JOA score improved significantly from 50.8 ± 15.1 points to 95.6 ± 7.6 points. No dislocations occurred in this study. We cut only the posterosuperior articular capsule and protected the internal obturator muscle to preserve muscle strength. We repaired the entire posterosuperior and anterior articular capsule. These treatments increase joint stability in the early postoperative period, thus reducing the dislocation rate. Therapeutic, Level IV.

  15. Inability of donor total body irradiation to prolong survival of vascularized bone allografts: Experimental study in the rat

    International Nuclear Information System (INIS)

    Gonzalez del Pino, J.; Benito, M.; Randolph, M.A.; Weiland, A.J.

    1990-01-01

    At the present time, the toxic side effects of recipient immunosuppression cannot be justified for human non-vital organ transplantation. Total body irradiation has proven effective in ablating various bone-marrow-derived and endothelial immunocompetent cellular populations, which are responsible for immune rejection against donor tissues. Irradiation at a dose of 10 Gy was given to donor rats six days prior to heterotopic transplantation of vascularized bone allografts to host animals. Another group of recipient rats also received a short-term (sixth to fourteenth day after grafting), low dose of cyclosporine. Total body irradiation was able merely to delay rejection of grafts across a strong histocompatibility barrier for one to two weeks, when compared to nonirradiated allografts. The combination of donor irradiation plus cyclosporine did not delay the immune response, and the rejection score was similar to that observed for control allografts. Consequently, allograft viability was quickly impaired, leading to irreversible bone damage. This study suggest that 10 Gy of donor total body irradiation delivered six days prior to grafting cannot circumvent the immune rejection in a vascularized allograft of bone across a strong histocompatibility barrier

  16. The effect of whole body or total-head x irradiation of the metallophilic cells in the mice spleen

    International Nuclear Information System (INIS)

    Sasaki, Osamu; Matsueda, Yasutoshi; Mizuguchi, Hiroshi; Moriguchi, Kenzo; Ogata, Kunitoshi; Sugie, Tsuneto

    1984-01-01

    The purpose of this paper is to clarify morphological changes of the reticuloendothelial cells in the spleen following X-irradiation by Katsura's silver impregnation method. The animals used in this experiment were ddN female mice weighing 20 to 25g. The mice were given X-irradiation to the total-head (1,500R) or whole body (300R). The metallophilic cells in the spleen of control mice were of the small foamy type in the follicle, the large stellate type in the marginal metallophils, the small branching type in the marginal zone and the small foamy or round type in the red pulp, respectively. The metallophilic cells decreased immediately after whole body irradiation and the number of cells returned to normal in from 10 to 14 days. On the other hand, the number of the metallophilic cells in the follicle and the perifollicular region increased immediately after total-head X-irradiation. This state continued for several days. In the marginal zone and red pulp, the number of amoebian type cells appeared from 24 hours after irradiation and the number of cells in total-head irradiation group were more clearly distinguishable than in the whole body irradiated group. (author)

  17. Treatment verification and in vivo dosimetry for total body irradiation using thermoluminescent and semiconductor detectors

    International Nuclear Information System (INIS)

    Oliveira, F.F.; Amaral, L.L.; Costa, A.M.; Netto, T.G.

    2014-01-01

    The objective of this work is the characterization of thermoluminescent and semiconductor detectors and their applications in treatment verification and in vivo dosimetry for total body irradiation (TBI) technique. Dose measurements of TBI treatment simulation performed with thermoluminescent detectors inserted in the holes of a “Rando anthropomorphic phantom” showed agreement with the prescribed dose. For regions of the upper and lower chest where thermoluminescent detectors received higher doses it was recommended the use of compensating dose in clinic. The results of in vivo entrance dose measurements for three patients are presented. The maximum percentual deviation between the measurements and the prescribed dose was 3.6%, which is consistent with the action level recommended by the International Commission on Radiation Units and Measurements (ICRU), i.e., ±5%. The present work to test the applicability of a thermoluminescent dosimetric system and of a semiconductor dosimetric system for performing treatment verification and in vivo dose measurements in TBI techniques demonstrated the value of these methods and the applicability as a part of a quality assurance program in TBI treatments. - Highlights: • Characterization of a semiconductor dosimetric system. • Characterization of a thermoluminescent dosimetric system. • Application of the TLDs for treatment verification in total body irradiation treatments. • Application of semiconductor detectors for in vivo dosimetry in total body irradiation treatments. • Implementation of in vivo dosimetry as a part of a quality assurance program in radiotherapy

  18. Body composition changes after totally laparoscopic distal gastrectomy with delta-shaped anastomosis: a comparison with conventional Billroth I anastomosis.

    Science.gov (United States)

    Park, Ki Bum; Kwon, Oh Kyoung; Yu, Wansik; Jang, Byeong-Churl

    2016-10-01

    The purpose of this study was to compare body composition changes of patients undergoing totally laparoscopic distal gastrectomy (TLDG) with delta-shaped anastomosis (DSA) versus conventional laparoscopic distal gastrectomy (CLDG). Data from gastric cancer patients who underwent laparoscopic distal gastrectomy for histologically proven gastric cancer in KNUMC from January 2013 to May 2014 were collected and reviewed. We examined 85 consecutive patients undergoing TLDG or CLDG: 41 patients underwent TLDG and 44 patients underwent CLDG. Body composition was assessed by segmental multifrequency bioelectrical impedance analysis. We compared the changes in nutritional parameters and body composition from preoperative status between the two groups at postoperative 6 and 12 months. All of the postoperative changes in the body composition and nutritional indices were similar between the two groups with the exception of visceral fat areas (VFAs) and albumin levels. VFAs increased at 6 months postoperatively in the TLDG group and a significant difference was shown at 12 months postoperatively between the TLDG and CLDG groups (86.7 ± 22.8 and 74.7 ± 21.9 cm(2), respectively, P body composition seemed comparable to those of CLDG. Six months postoperatively, VFAs and albumin levels were recovered in the TLDG group but not in the CLDG group. Thus, TLDG seems to be a novel surgical method.

  19. Reverse Total Shoulder Arthroplasty as Treatment for Rotator Cuff-Tear Arthropathy and Shoulder Dislocations in an Elderly Male with Parkinson’s Disease

    Directory of Open Access Journals (Sweden)

    John G. Skedros

    2017-01-01

    Full Text Available We report the case of a 70-year-old male with Parkinson’s disease (PD and recurrent traumatic left shoulder dislocations. This case is rare because (1 he had a massive irreparable rotator cuff tear and end-stage arthritis (i.e., rotator cuff-tear arthropathy of the same shoulder and (2 his shoulder was ultimately reconstructed with a reverse total shoulder arthroplasty (RTSA. His first dislocation occurred after a fall. Recurrent shoulder dislocations occurred despite successful closed reduction and physical therapy. Initial surgical treatment included an open capsular-labral reconstruction; RTSA was not an ideal option because of the presumed risk of failure from PD-related dyskinesias. However, the capsular-labral reconstruction failed after he lost balance and stumbled but did not fall. A RTSA was then done which restored the patient’s shoulder stability and greatly improved his pain. At final follow-up two years later, he reported pain relief and improved function. This was partially attributed to the fact that he had moved to an assisted living center. He also began using an electric wheelchair one year after the RTSA. We report this case because of the unusual set of conditions and circumstances, namely, the implantation of a RTSA in a patient with PD and shoulder instability.

  20. Total Energy Expenditure, Energy Intake, and Body Composition in Endurance Athletes Across the Training Season: A Systematic Review.

    Science.gov (United States)

    Heydenreich, Juliane; Kayser, Bengt; Schutz, Yves; Melzer, Katarina

    2017-12-01

    Endurance athletes perform periodized training in order to prepare for main competitions and maximize performance. However, the coupling between alterations of total energy expenditure (TEE), energy intake, and body composition during different seasonal training phases is unclear. So far, no systematic review has assessed fluctuations in TEE, energy intake, and/or body composition in endurance athletes across the training season. The purpose of this study was to (1) systematically analyze TEE, energy intake, and body composition in highly trained athletes of various endurance disciplines and of both sexes and (2) analyze fluctuations in these parameters across the training season. An electronic database search was conducted on the SPORTDiscus and MEDLINE (January 1990-31 January 2015) databases using a combination of relevant keywords. Two independent reviewers identified potentially relevant studies. Where a consensus was not reached, a third reviewer was consulted. Original research articles that examined TEE, energy intake, and/or body composition in 18-40-year-old endurance athletes and reported the seasonal training phases of data assessment were included in the review. Articles were excluded if body composition was assessed by skinfold measurements, TEE was assessed by questionnaires, or data could not be split between the sexes. Two reviewers assessed the quality of studies independently. Data on subject characteristics, TEE, energy intake, and/or body composition were extracted from the included studies. Subjects were categorized according to their sex and endurance discipline and each study allocated a weight within categories based on the number of subjects assessed. Extracted data were used to calculate weighted means and standard deviations for parameters of TEE, energy intake, and/or body composition. From 3589 citations, 321 articles were identified as potentially relevant, with 82 meeting all of the inclusion criteria. TEE of endurance athletes was

  1. Identification of Combined Power Quality Disturbances Using Singular Value Decomposition (SVD and Total Least Squares-Estimation of Signal Parameters via Rotational Invariance Techniques (TLS-ESPRIT

    Directory of Open Access Journals (Sweden)

    Huaishuo Xiao

    2017-11-01

    Full Text Available In order to identify various kinds of combined power quality disturbances, the singular value decomposition (SVD and the improved total least squares-estimation of signal parameters via rotational invariance techniques (TLS-ESPRIT are combined as the basis of disturbance identification in this paper. SVD is applied to identify the catastrophe points of disturbance intervals, based on which the disturbance intervals are segmented. Then the improved TLS-ESPRIT optimized by singular value norm method is used to analyze each data segment, and extract the amplitude, frequency, attenuation coefficient and initial phase of various kinds of disturbances. Multi-group combined disturbance test signals are constructed by MATLAB and the proposed method is also tested by the measured data of IEEE Power and Energy Society (PES Database. The test results show that the new method proposed has a relatively higher accuracy than conventional TLS-ESPRIT, which could be used in the identification of measured data.

  2. Percutaneous recanalization of chronic total occlusions: wherein lies the body of proof?

    Science.gov (United States)

    Tamburino, Corrado; Capranzano, Piera; Capodanno, Davide; Dangas, George; Zimarino, Marco; Bass, Theodore A; Mehran, Roxana; Antoniucci, David; Colombo, Antonio; La Manna, Alessio; Di Salvo, Maria E; Stone, Gregg W

    2013-02-01

    Although interventional technology and skills have markedly advanced, percutaneous coronary intervention (PCI) for coronary chronic total occlusion (CTO) lesions remains challenging. Indeed, CTO PCI is technically complex, carries the potential for a relatively high likelihood of failure and acute complications, and requires specifically skilled operators and a demanding use of resources. In addition, controversy persists surrounding appropriate indications for attempting CTO revascularization. Finally, there is a wide uncertainty on the actual benefits achieved with successful CTO recanalization. A growing number of studies have reported procedural results and/or assessed functional effects and long-term clinical outcomes of CTO PCI. We therefore sought to review and critically appraise the evidence base for procedural outcomes and potential clinical benefits of CTO PCI. Copyright © 2013 Mosby, Inc. All rights reserved.

  3. Cumulative total effective whole-body radiation dose in critically ill patients.

    Science.gov (United States)

    Rohner, Deborah J; Bennett, Suzanne; Samaratunga, Chandrasiri; Jewell, Elizabeth S; Smith, Jeffrey P; Gaskill-Shipley, Mary; Lisco, Steven J

    2013-11-01

    Uncertainty exists about a safe dose limit to minimize radiation-induced cancer. Maximum occupational exposure is 20 mSv/y averaged over 5 years with no more than 50 mSv in any single year. Radiation exposure to the general population is less, but the average dose in the United States has doubled in the past 30 years, largely from medical radiation exposure. We hypothesized that patients in a mixed-use surgical ICU (SICU) approach or exceed this limit and that trauma patients were more likely to exceed 50 mSv because of frequent diagnostic imaging. Patients admitted into 15 predesignated SICU beds in a level I trauma center during a 30-day consecutive period were prospectively observed. Effective dose was determined using Huda's method for all radiography, CT imaging, and fluoroscopic examinations. Univariate and multivariable linear regressions were used to analyze the relationships between observed values and outcomes. Five of 74 patients (6.8%) exceeded exposures of 50 mSv. Univariate analysis showed trauma designation, length of stay, number of CT scans, fluoroscopy minutes, and number of general radiographs were all associated with increased doses, leading to exceeding occupational exposure limits. In a multivariable analysis, only the number of CT scans and fluoroscopy minutes remained significantly associated with increased whole-body radiation dose. Radiation levels frequently exceeded occupational exposure standards. CT imaging contributed the most exposure. Health-care providers must practice efficient stewardship of radiologic imaging in all critically ill and injured patients. Diagnostic benefit must always be weighed against the risk of cumulative radiation dose.

  4. The effects of dose rate in total body irradiation of dogs

    International Nuclear Information System (INIS)

    Kolb, H.J.; Bodenberger, U.; Holler, E.; Thierfelder, S.; Eckstein, R.

    1986-01-01

    In summary the studies in dogs show that the dose rate or exposure time has a great impact on survival of acute radiation syndromes. In contrast the inactivation of colony forming hemopoietic precursors is less influenced by the dose rate. The potential of hemopoietic recovery is determined by the survival of hemopoietic precursor cells. Therefore in patients with a suspected whole body exposure of more than 1.50 Gy, bacterial and fungal decontamination and reverse isolation in a sterile environment has to be started immediately. Human patients treated with about 10 Gy of TBI frequently developed nausea, elevated temperatures and swelling of the parotic glands at the first and second day. The extent of these changes varies from patient to patient. The temperature is rarely elevated above 38.5 0 C. The swelling of parotics and the nausea subside within 48 hours. The presence of such systemic symptoms may suggest the exposure to a lethal dose of radiation. The disappearance of immature red cells, i.e. reticulocytes, and bandforms of granulocytes within the first 5 days supports this suggestion. HLA typing of the victim and his family should be performed as soon as possible after the accident. An HLA-identical sibling would be a suitable bone marrow donor. Unlike therapeutic TBI accidental exposures bring about uncertainties in the calculation of dose, dose distribution and dose rate. Early after irradiation biological changes are extremely variable. Both biological and physical data have to be considered, when microbiological decontamination, reverse isolation and transplantation of bone marrow are to be decided upon. Obviously these intensive therapeutic efforts are limited to a small number of victims. (orig.)

  5. Thioacetamide-induced changes in the body weight, kidney weight and the total nucleic acids content of kidney of mouse

    International Nuclear Information System (INIS)

    Shakoori, Abdul Rauf; Ashraf, Fauzia.

    1976-01-01

    Effects of thioacetamide (TAA) on the body weight, kidney weight and the total nucleic acids content of kidney of mouse were studied. TAA 1% and 2% solutions were injected intraperitoneally, twice with an interval of 24 hours in two different batches of male mice. In this way one batch received a total dose of 100 mg TAA/Kg body wt. while the other got a total dose of 200 mg TAA/Kg. Both the body as well as kidney weights decrease after TAA treatment. A total dose of 200 mg/Kg is a stronger inhibitor of growth as compared with that of 100 mg/Kg. The nucleic acids content show an increase after the drug treatment. The ribonucleic acid content of kidney increased from an average value of 4.30+0.14 mg/g kidney to 4.60+-0.22 mg/g kidney after 1% TAA treatment. The increase in 2% TAA treated mice is slightly more prominent. The deoxyribonucleic acid (DNA) content of kidney are likewise affected. After an initial increase in 1% TAA-treated animals, the DNA content gradually fall down to normal control values. Administration of 2% TAA solution causes an average increase of 21% i.e. from 1.93+-0.19 mg/g kidney wt to 2.26+-0.23 mg/g kidney wt. The size of cell, nucleus and nucleolus also increased after drug treatment, which mainly occurred during the first 24 hours of the post-treatment period

  6. Biochemical and hematological indicators in model of total body irradiation; Indicadores bioquimicos y hematologicos en un modelo de irradiacion corporal total

    Energy Technology Data Exchange (ETDEWEB)

    Dubner, D; Gisone, P; Perez, M R [Autoridad Regulatoria Nuclear, Buenos Aires (Argentina); Barboza, M [Hospital de Clinicas Jose de San Martin, Buenos Aires (Argentina); Luchetta, P; Longoni, H; Sorrentino, M; Robison, A [Hospital Naval Pedro Mallo, Buenos Aires (Argentina)

    1998-07-01

    With the purpose of evaluating the applicability of several biological indicators in accidental overexposures a study was carried out in 20 patients undergoing therapeutical total body irradiation (TBI). The following parameters were evaluated: a) Oxidative stress indicators: erythrocyte superoxide dismutase (SOD) and catalase activity (CAT), lipo peroxyde levels (TBARS) and total plasma antioxidant activity (TAA). b) Haematological indicators: reticulocyte maturity index (RMI) and charges in lymphocyte subpopulations. Non significant changes in SOD and CAT activity were observed. Significant higher TBARS levels were found in patients with unfavorable post-BTM course without any significant correlation with TAA. RMI decreased early and dropped to zero in most of the patients and rose several days prior to reticulocyte, neutrophils and platelets counts. A significant decrease in absolute counts of all lymphocyte subpopulations was observed during TBI, particularly for B lymphocytes. A subpopulation of natural killer (NK) cells (CD16+/ CD 56 +) showed a relative higher radioresistance. Cytotoxic activity was significantly decreased after TBI. These data suggest that TBARS could provide an useful evolutive indicator in accidental over exposure d patients and RMI is an early indicator of bone marrow recovery after radioinduced aplasia. The implications of the different radiosensitivities within the NK subsets remains unanswered. (author) [Spanish] Se presentan los resultados de un estudio multiparametrico realizado en pacientes sometidos a irradiacion corporal total (ICT) a fin de evaluar al aplicabilidad de ciertos indicadores bioquimicos y hematologicos en personas accidentalmente sobreexpuestas a radiaciones ionizantes. El trabajo se realizo en pacientes incluidos en un protocolo de irradiacion terapeutica (12 Gy / 4 dias) previo a un transplante de medula osea (TMO). Se tomaron muestras secuenciales de sangre periferica hasta el alta del paciente. Se evaluaron: a

  7. Inhaled /sup 147/Pm and/or total-body gamma radiation: Early mortality and morbidity in rats

    Energy Technology Data Exchange (ETDEWEB)

    Filipy, R.E.; Lauhala, K.E.; McGee, D.R.; Cannon, W.C.; Buschbom, R.L.; Decker, J.R.; Kuffel, E.G.; Park, J.F.; Ragan, H.A.; Yaniv, S.S.; Scott, B.R.

    1989-05-01

    Rats were given doses of /sup 60/Co gamma radiation and/or lung burdens of /sup 147/Pm (in fused aluminosilicate particles) within lethal ranges in an experiment to determine and compare morbidity and mortality responses for the radiation insults within 1 year after exposure. Radiation-induced morbidity was assessed by measuring changes in body weights, hematologic parameters, and pulmonary-function parameters. Acute mortality and morbidity from inhaled promethium were caused primarily by radiation pneumonitis and pulmonary fibrosis that occurred more than 53 days after exposure. Acute mortality and morbidity from total-body gamma irradiation occurred within 30 days of exposure and resulted from the bone-marrow radiation syndrome. Gamma radiation caused transient morbidity, reflected by immediately depressed blood cell levels and by reduced body weight gain in animals that survived the acute gamma radiation syndrome. Inhaled promethium caused a loss of body weight and diminished pulmonary function, but its only effect on blood cell levels was lymphocytopenia. Combined gamma irradiation and promethium lung burdens were synergistic, in that animals receiving both radiation insults had higher morbidity and mortality rates than would be predicted based on the effect of either kind of radiation alone. Promethium lung burdens enhanced the effect of gamma radiation in rats within the first 30 days of exposure, and gamma radiation enhanced the later effect of promethium lung burdens. 70 refs., 68 figs., 21 tabs.

  8. Body composition of adult cystic fibrosis patients and control subjects as determined by densitometry, bioelectrical impedance, total-body electrical conductivity, skinfold measurements, and deuterium oxide dilution

    International Nuclear Information System (INIS)

    Newby, M.J.; Keim, N.L.; Brown, D.L.

    1990-01-01

    This study contrasts body compositions (by six methods) of eight cystic fibrosis (CF) subjects with those of eight control subjects matched for age, height, and sex. CF subjects weighed 84% as much as control subjects. Densitometry and two bioelectrical impedance-analysis methods suggested that reduced CF weights were due to less lean tissue (10.7, 9.5, and 10.4 kg). Total-body electrical conductivity (TOBEC) and skinfold-thickness measurements indicated that CF subjects were leaner than control subjects and had less fat (5.4 and 3.6 kg) and less lean (5.2 and 7 kg) tissue. D2O dilution showed a pattern similar to TOBEC (8.3 kg less lean, 2.7 kg less fat tissue). Densitometry estimates of fat (mass and percent) were not correlated (r less than 0.74, p greater than 0.05) with any other method for CF subjects but were correlated with all other methods for control subjects. CF subjects contained less fat and lean tissue than did control subjects. Densitometry by underwater weighing is unsuitable for assessing body composition of CF patients

  9. Prognosis and bone marrow recovery indicators in bone marrow transplantation after total body irradiation

    International Nuclear Information System (INIS)

    Dubner, Diana; Perez, Maria del R.; Gisone, Pablo; Barboza, Marcos; Sorrentino, Miguel; Robinson, Anibal

    2002-01-01

    Oxidative stress and reticulocyte maturity index (RMI) were studied in 27 patients who underwent bone marrow transplantation (BMT). Plasmatic lipo peroxide levels of those patients with unfavorable evolution were significantly increases on days 12-14 post-transplant (median 1,83 μM, range 0.78-5.82) compared with preconditioning levels (median 1.05 μM, range 0.36-1.84) (p<0.05). Patients with favorable evolution revealed significantly higher lipo peroxide levels during conditioning regime (median 1.42 μM, range 0.31-4.50) (p<0.05). Starting from the 3rd. post-transplant week a significant and continuous decrease was observed, with a median of 0.77 μM (range 0.21-1.48) (p<0.05) for the 3rd, and a median of 0.60 μM (range 0.11-1.48) for the 4th. week (p<0.01). A significant increase in total antioxidant activity was observed in the three patients who died up to the 35 days post-transplant. Recovery of bone marrow function was detected by RMI after a median time of 17 days (range 11-24) post-allogeneic transplantation. The threshold established for absolute neutrophil count was achieved after a median of 21 days (range 14-28) (p<0.001). An increase of plasma lipo peroxides on days 12-14 post transplant may be a predictive value of unfavourable evolution. RMI was the earlier indicator of engraftment in allogeneic BMT. (author)

  10. Effect of fractionated versus unfractionated total body irradiation on the growth of the BN acute myelocytic leukemia

    International Nuclear Information System (INIS)

    Hagenbeek, A.; Martens, A.C.M.

    1981-01-01

    The efficacy of various total body irradiation (TBI) regimens prior to bone marrow transplantation was evaluated in a rat model for acute myelocytic leukemia (Dq = 85.1 cGy gamma ; N = 3.7). Using high dose rate gamma-irradiation (115 cGy/min), fractionated TBI with large total daily doses (400 to 600 cGy), either given as acute doses or as split doses at 8 hr intervals, was most effective. Split doses (2 fractions per day) offered no additional advantage. At the most, a 4 log leukemic cell kill was induced. No lethal toxicity was observed. Nine-hundred cGy flash TBI had a similar anti-tumor effect, but with this regimen almost half of the rats died from radiation-induced toxicity (lungs and gastro-intestinal tract). The results are explained in terms of differences between normal and leukemic cells as regards (a) repair of sublethal damage; and (b) repopulation. Low dose rate continuous gamma-irradiation (0.26 cGy/min) with total doses ranging from 900 to 2000 cGy was also quite effective. Maximally a 4 log cell kill was obtained. With 2000 cGy, 50% of the rats died from the gastro-intestinal tract-syndrome. In addition to the major role played by chemotherapy, TBI is mainly of importance in sterilizing the various sanctuaries in the body which contain leukemic cells anatomically resistant to most cytostatic agents

  11. Quantitative estimation of 123I-MIBG scintigraphy in neuroblastoma. Usefulness of the total body retention rate

    International Nuclear Information System (INIS)

    Okuyama, Chio; Ushijima, Yo; Sugihara, Hiroki; Nishimura, Tunehiko

    2000-01-01

    A new method of easily and simply quantifying 123 I-MIBG accumulation as a criterion for curative effect of chemotherapy in infants with neuroblastoma was developed. This method uses the data from two images: an early image (at 5-7.5 hr) and a delayed image (at 25-32 hr). Twenty infants with untreated neuroblastoma which showed clear accumulation of 123 I-MIBG at the primary site were examined. The differences between the accumulation counts on the early image and the delayed image showed that washout of 123 I-MIBG in the neuroblastomas was delayed in tumor regions. This finding indicated that the total body 123 I-MIBG retention rate reflects the total volume of the neuroblastoma. The 123 I-MIBG retention rate was significantly higher in patients with advanced stage neuroblastoma with systemic metastases, and there was a good correlation between the retention rate and tumor markers (VMA and HVA values in urine). The response to chemotherapy paralleled the change in markers. These results suggested that the total body 123 I-MIBG retention rate is useful as a criterion for curative effect in advanced neuroblastoma. (K.H.)

  12. Poisson equations of rotational motion for a rigid triaxial body with application to a tumbling artificial satellite

    Science.gov (United States)

    Liu, J. J. F.; Fitzpatrick, P. M.

    1975-01-01

    A mathematical model is developed for studying the effects of gravity gradient torque on the attitude stability of a tumbling triaxial rigid satellite. Poisson equations are used to investigate the rotation of the satellite (which is in elliptical orbit about an attracting point mass) about its center of mass. An averaging method is employed to obtain an intermediate set of differential equations for the nonresonant, secular behavior of the osculating elements which describe the rotational motions of the satellite, and the averaged equations are then integrated to obtain long-term secular solutions for the osculating elements.

  13. THE IMPACT OF MODERATE AND HIGH INTENSITY TOTAL BODY FATIGUE ON PASSING ACCURACY IN EXPERT AND NOVICE BASKETBALL PLAYERS

    Directory of Open Access Journals (Sweden)

    Mark Lyons

    2006-06-01

    Full Text Available Despite the acknowledged importance of fatigue on performance in sport, ecologically sound studies investigating fatigue and its effects on sport-specific skills are surprisingly rare. The aim of this study was to investigate the effect of moderate and high intensity total body fatigue on passing accuracy in expert and novice basketball players. Ten novice basketball players (age: 23.30 ± 1.05 yrs and ten expert basketball players (age: 22.50 ± 0.41 yrs volunteered to participate in the study. Both groups performed the modified AAHPERD Basketball Passing Test under three different testing conditions: rest, moderate intensity and high intensity total body fatigue. Fatigue intensity was established using a percentage of the maximal number of squat thrusts performed by the participant in one minute. ANOVA with repeated measures revealed a significant (F 2,36 = 5.252, p = 0.01 level of fatigue by level of skill interaction. On examination of the mean scores it is clear that following high intensity total body fatigue there is a significant detriment in the passing performance of both novice and expert basketball players when compared to their resting scores. Fundamentally however, the detrimental impact of fatigue on passing performance is not as steep in the expert players compared to the novice players. The results suggest that expert or skilled players are better able to cope with both moderate and high intensity fatigue conditions and maintain a higher level of performance when compared to novice players. The findings of this research therefore, suggest the need for trainers and conditioning coaches in basketball to include moderate, but particularly high intensity exercise into their skills sessions. This specific training may enable players at all levels of the game to better cope with the demands of the game on court and maintain a higher standard of play

  14. Enrichment increases hippocampal neurogenesis independent of blood monocyte-derived microglia presence following high-dose total body irradiation.

    Science.gov (United States)

    Ruitenberg, Marc J; Wells, Julia; Bartlett, Perry F; Harvey, Alan R; Vukovic, Jana

    2017-06-01

    Birth of new neurons in the hippocampus persists in the brain of adult mammals and critically underpins optimal learning and memory. The process of adult neurogenesis is significantly reduced following brain irradiation and this correlates with impaired cognitive function. In this study, we aimed to compare the long-term effects of two environmental paradigms (i.e. enriched environment and exercise) on adult neurogenesis following high-dose (10Gy) total body irradiation. When housed in standard (sedentary) conditions, irradiated mice revealed a long-lasting (up to 4 months) deficit in neurogenesis in the granule cell layer of the dentate gyrus, the region that harbors the neurogenic niche. This depressive effect of total body irradiation on adult neurogenesis was partially alleviated by exposure to enriched environment but not voluntary exercise, where mice were single-housed with unlimited access to a running wheel. Exposure to voluntary exercise, but not enriched environment, did lead to significant increases in microglia density in the granule cell layer of the hippocampus; our study shows that these changes result from local microglia proliferation rather than recruitment and infiltration of circulating Cx 3 cr1 +/gfp blood monocytes that subsequently differentiate into microglia-like cells. In summary, latent neural precursor cells remain present in the neurogenic niche of the adult hippocampus up to 8 weeks following high-dose total body irradiation. Environmental enrichment can partially restore the adult neurogenic process in this part of the brain following high-dose irradiation, and this was found to be independent of blood monocyte-derived microglia presence. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  15. The nucleic acids as early indicators of the recovery of patients subjected to total body irradiation for bone marrow transplant

    International Nuclear Information System (INIS)

    Morera Carrillo, L.M.; Garcia Lima, O.; Carnot, J.; Cardenas, J.

    2000-01-01

    The possibility to use the concentration of nucleic acids as an early indicator for the recovery of individuals exposed to high radiation was valued in 30 patients subjected to a dose of 10 Gy (cobalt 60) in two or three sessions of total body irradiation for bone marrow transplants. The determination of the concentration of the nucleic acids was carried out prior to the irradiation, and later in different periods until the patients discharge. The behaviour of indicate such as alpha amylase serics transaminases, glicemics, alkaline phosphatase and others was also studied

  16. Clinical responses after total body irradiation by over permissible dose of γ-rays in one time

    International Nuclear Information System (INIS)

    Jiang Benrong; Wang Guilin; Liu Huilan; Tang Xingsheng; Ai Huisheng

    1990-01-01

    The clinical responses of patients after total body over permissilbe dose γ-ray irradiation were observed and analysed. The results showed: when the dose was above 5 cGy, there was some immunological depression, but no significant change in hematopoietic functions. 5 cases showed some transient changes of ECG, perhaps due to vagotonia caused by psychological imbalance, One case vomitted 3-4 times after 28 cGy irradiation, this suggested that a few times of vomitting had no significance in the estimation of the irradiated dose and the whole clinical manifestations must be concretely analysed

  17. Fractionated total body irradiation; the gastrointestinal toxicity versus the conditioning effect for bone marrow transplantation with different fractionation schedules

    International Nuclear Information System (INIS)

    Walma, E.P.; Klapwijk, W.M.; Miller, A.M.

    1982-01-01

    In most cases, bone marrow transplantation is preceded by a conditioning regimen employing irradiation and/or cytotoxic drugs. The authors are searching for better fractionation schedules in order to optimize the conditioning regimen prior to transplantation of stem-cell-enriched bone marrow. They have determined damage to the gastrointestinal tract in dogs and mice after total body irradiation in mice and dogs following a number of fractionation schedules, and these results are presented. The schedules were chosen such as to minimize the interval between irradiation and the bone marrow transplantation and to maximize clinical feasibility. (Auth./C.F.)

  18. Beam’s-eye-view dosimetrics (BEVD) guided rotational station parameter optimized radiation therapy (SPORT) planning based on reweighted total-variation minimization

    Science.gov (United States)

    Kim, Hojin; Li, Ruijiang; Lee, Rena; Xing, Lei

    2015-03-01

    Conventional VMAT optimizes aperture shapes and weights at uniformly sampled stations, which is a generalization of the concept of a control point. Recently, rotational station parameter optimized radiation therapy (SPORT) has been proposed to improve the plan quality by inserting beams to the regions that demand additional intensity modulations, thus formulating non-uniform beam sampling. This work presents a new rotational SPORT planning strategy based on reweighted total-variation (TV) minimization (min.), using beam’s-eye-view dosimetrics (BEVD) guided beam selection. The convex programming based reweighted TV min. assures the simplified fluence-map, which facilitates single-aperture selection at each station for single-arc delivery. For the rotational arc treatment planning and non-uniform beam angle setting, the mathematical model needs to be modified by additional penalty term describing the fluence-map similarity and by determination of appropriate angular weighting factors. The proposed algorithm with additional penalty term is capable of achieving more efficient and deliverable plans adaptive to the conventional VMAT and SPORT planning schemes by reducing the dose delivery time about 5 to 10 s in three clinical cases (one prostate and two head-and-neck (HN) cases with a single and multiple targets). The BEVD guided beam selection provides effective and yet easy calculating methodology to select angles for denser, non-uniform angular sampling in SPORT planning. Our BEVD guided SPORT treatment schemes improve the dose sparing to femoral heads in the prostate and brainstem, parotid glands and oral cavity in the two HN cases, where the mean dose reduction of those organs ranges from 0.5 to 2.5 Gy. Also, it increases the conformation number assessing the dose conformity to the target from 0.84, 0.75 and 0.74 to 0.86, 0.79 and 0.80 in the prostate and two HN cases, while preserving the delivery efficiency, relative to conventional single-arc VMAT plans.

  19. Beam’s-eye-view dosimetrics (BEVD) guided rotational station parameter optimized radiation therapy (SPORT) planning based on reweighted total-variation minimization

    International Nuclear Information System (INIS)

    Kim, Hojin; Li, Ruijiang; Xing, Lei; Lee, Rena

    2015-01-01

    Conventional VMAT optimizes aperture shapes and weights at uniformly sampled stations, which is a generalization of the concept of a control point. Recently, rotational station parameter optimized radiation therapy (SPORT) has been proposed to improve the plan quality by inserting beams to the regions that demand additional intensity modulations, thus formulating non-uniform beam sampling. This work presents a new rotational SPORT planning strategy based on reweighted total-variation (TV) minimization (min.), using beam’s-eye-view dosimetrics (BEVD) guided beam selection. The convex programming based reweighted TV min. assures the simplified fluence-map, which facilitates single-aperture selection at each station for single-arc delivery. For the rotational arc treatment planning and non-uniform beam angle setting, the mathematical model needs to be modified by additional penalty term describing the fluence-map similarity and by determination of appropriate angular weighting factors. The proposed algorithm with additional penalty term is capable of achieving more efficient and deliverable plans adaptive to the conventional VMAT and SPORT planning schemes by reducing the dose delivery time about 5 to 10 s in three clinical cases (one prostate and two head-and-neck (HN) cases with a single and multiple targets). The BEVD guided beam selection provides effective and yet easy calculating methodology to select angles for denser, non-uniform angular sampling in SPORT planning. Our BEVD guided SPORT treatment schemes improve the dose sparing to femoral heads in the prostate and brainstem, parotid glands and oral cavity in the two HN cases, where the mean dose reduction of those organs ranges from 0.5 to 2.5 Gy. Also, it increases the conformation number assessing the dose conformity to the target from 0.84, 0.75 and 0.74 to 0.86, 0.79 and 0.80 in the prostate and two HN cases, while preserving the delivery efficiency, relative to conventional single-arc VMAT plans

  20. Body-force-driven multiplicity and stability of combined free and forced convection in rotating curved ducts: Coriolis force

    Science.gov (United States)

    Yang, T.; Wang, L.

    A numerical study is made on the fully developed bifurcation structure and stability of forced convection in a rotating curved duct of square cross-section. Solution structure is determined as variation of a parameter that indicates the effect of rotation (Coriolis-force-driven multiplicity). Three solutions for the flows in a stationary curved duct obtained in the work of Yang and Wang [1] are used as initial solutions of continuation calculations to unfold the solution branches. Twenty-one solution branches are found comparing with five obtained by Selmi and Nandakumar [2]. Dynamic responses of the multiple solutions to finite random disturbances are examined by the direct transient computation. Results show that characteristics of physically realizable fully developed flows changes significantly with variation of effect of rotation. Fourteen sub-ranges are identified according to characteristics of physically realizable solutions. As rotation effect changes, possible physically realizable fully-developed flows can be stable steady 2-cell state, stable multi-cell state, temporal periodic oscillation between symmetric/asymmetric 2-cell/4-cell flows, temporal oscillation with intermittency, temporal chaotic oscillation and temporal oscillation with pseudo intermittency. Among these possible physically realizable fully developed flows, stable multi-cell state and stable steady 2-cell state exist as dual stable. And oscillation with pseudo intermittency is a new phenomenon. In addition to the temporal oscillation with intermittency, sudden shift from stationary stable solution to temporal chaotic oscillation is identified to be another way of onset of chaos.

  1. Comparison of 24 hr total body radio-iodine retention for hypothyroid vs. thyrogen (rhTSH) stimulated whole body surveillance scan

    International Nuclear Information System (INIS)

    Jana, S.; Young, I.; Bukberg, P.; Luo, J.Q.; Dakhel, M.; Heiba, S.; El-Zeftawy, H.; Abdel-Dayem, H.M.

    2002-01-01

    Objective: Recently rhTSH has been used for WBS to avoid hypothyroid symptoms from T4/T3 withdrawal. There is limited data available in the current literature comparing total body radio-iodine clearance between hypothyroid pts and pts receiving rhTSH. Significant differences in radio-iodine clearance may influence the dose of radio-iodine required for diagnostic scanning or treatment of pts on a rhTSH protocol. Methods: To retrospectively compare the 24 hr total body I-123 retention in thyroid cancer pts who were made hypothyroid in preparation for radio-iodine scanning with the I-123 retention in pts who received thyrogen (rhTSH) but were maintained on thyroid hormone replacement. Inclusion criteria were as follows: Histologically diagnosed well diff. thyroid Ca s/p surgery and I-131 Rx in the past who were clinically disease free at the time of scanning. No abn. visible I-123 uptake on WBS and 24 hr neck uptake ≤ 1%. Tg level ≤ 2ng off T4/T3 or ≤ 2ng increase from basal level after rhTSH. Anti-Tg Ab negative. Serum Creatine ≤ 1.4 mg/dl. Serum ALT < 35, AST < 35. Total 78 pts were divided into the following 3 groups (Gp): Gp-1 (29 pts) received 2 IM inj. Of 0.9 mg rhTSH 24 and 48 hrs prior to oral dose of 10 mCi I-123. Gp-2 (30 pts) followed hypothyroid protocol i.e., off T4 ≥ 4 wks or T3 ≥ 10 days in order to achieve TSH ≥ 30 MIU/L. The dose of I-123 was 5 mCi. Gp-3 (19 pts) similar to Gp-2 i.e., hypothyroid but scanned using 10 mCi of I-123. Imaging protocol: Pts were scanned 4 hrs and 24 hrs after I-123 administration in a dual head gamma camera for 30 mins. Total body and neck counting were obtained from the geometric mean of Ant and Post images with appropriate decay correction. 24 hr total body retention (TBR) of I-123 were calculated and expressed in %, considering 100% at 4 hrs. Results: Demographic Profile of 3 Patient Groups. AST/ALT was < 35 and 24 hrs neck uptake was ≤ 1.0% all pts. Comparison of 24 hr % TBR of I-123 in 3 Patient Groups

  2. Incidence of interstitial pneumonia after hyperfractionated total body irradiation before autologous bone marrow/stem cell transplantation

    International Nuclear Information System (INIS)

    Lohr, F.; Schraube, P.; Wenz, F.; Flentje, M.; Kalle, K. von; Haas, R.; Hunstein, W.; Wannenmacher, M.

    1995-01-01

    Purpose/Objectives Interstitial pneumonia (IP) is a severe complication after allogenic bone marrow transplantation (BMT) with incidence rates between 10 % and 40 % in different series. It is a polyetiologic disease that occurs depending on age, graft vs. host disease (GvHD), CMV-status, total body irradiation (TBI) and immunosuppressive therapy after BMT. The effects of fractionation and dose rate are not entirely clear. This study evaluates the incidence of lethal IP after hyperfractionated TBI for autologous BMT or stem cell transplantation. Materials and Methods Between 1982 and 1992, 182 patients (60 % male, 40 % female) were treated with hyperfractionated total body irradiation (TBI) before autologous bone marrow transplantation. Main indications were leukemias and lymphomas (53 % AML, 21 % ALL, 22 % NHL, 4 % others) Median age was 30 ys (15 - 55 ys). A total dose of 14.4 Gy was applied using lung blocks (12 fractions of 1.2 Gy in 4 days, dose rate 7-18 cGy/min, lung dose 9 - 9.5 Gy). TBI was followed by cyclophosphamide (200 mg/kg). 72 % were treated with bone marrow transplantation, 28 % were treated with stem cell transplantation. Interstitial pneumonia was diagnosed clinically, radiologically and by autopsy. Results 4 patients died most likely of interstitial pneumonia. For another 12 patients interstitial pneumonia was not the most likely cause of death but could not be excluded. Thus, the incidence of lethal IP was at least 2.2 % but certainly below 8.8 %. Conclusion Lethal interstitial pneumonia is a rare complication after total body irradiation before autologous bone marrow transplantation in this large, homogeously treated series. In the autologous setting, total doses of 14.4 Gy can be applied with a low risk for developing interstitial pneumonia if hyperfractionation and lung blocks are used. This falls in line with data from series with identical twins or t-cell depleted marrow and smaller, less homogeneous autologous transplant studies. Thus

  3. Immediate total-body CT scanning versus conventional imaging and selective CT scanning in patients with severe trauma (REACT-2): a randomised controlled trial

    NARCIS (Netherlands)

    Sierink, Joanne C.; Treskes, Kaij; Edwards, Michael J. R.; Beuker, Benn J. A.; den Hartog, Dennis; Hohmann, Joachim; Dijkgraaf, Marcel G. W.; Luitse, Jan S. K.; Beenen, Ludo F. M.; Hollmann, Markus W.; Goslings, J. Carel; Saltzherr, T. P.; Schep, N. W. L.; Streekstra, G. J.; van Lieshout, E. M. M.; Patka, P.; Klimek, M.; van Vugt, R.; Tromp, T. J. N.; Brink, M.; Harbers, J. S.; El Moumni, M.; Wendt, K. W.; Bingisser, R.; Ummenhofer, W.; Bless, N.

    2016-01-01

    Published work suggests a survival benefit for patients with trauma who undergo total-body CT scanning during the initial trauma assessment; however, level 1 evidence is absent. We aimed to assess the effect of total-body CT scanning compared with the standard work-up on in-hospital mortality in

  4. Total body irradiation with a compensator fabricated using a 3D optical scanner and a 3D printer.

    Science.gov (United States)

    Park, So-Yeon; Kim, Jung-In; Joo, Yoon Ha; Lee, Jung Chan; Park, Jong Min

    2017-05-07

    We propose bilateral total body irradiation (TBI) utilizing a 3D printer and a 3D optical scanner. We acquired surface information of an anthropomorphic phantom with the 3D scanner and fabricated the 3D compensator with the 3D printer, which could continuously compensate for the lateral missing tissue of an entire body from the beam's eye view. To test the system's performance, we measured doses with optically stimulated luminescent dosimeters (OSLDs) as well as EBT3 films with the anthropomorphic phantom during TBI without a compensator, conventional bilateral TBI, and TBI with the 3D compensator (3D TBI). The 3D TBI showed the most uniform dose delivery to the phantom. From the OSLD measurements of the 3D TBI, the deviations between the measured doses and the prescription dose ranged from  -6.7% to 2.4% inside the phantom and from  -2.3% to 0.6% on the phantom's surface. From the EBT3 film measurements, the prescription dose could be delivered to the entire body of the phantom within  ±10% accuracy, except for the chest region, where tissue heterogeneity is extreme. The 3D TBI doses were much more uniform than those of the other irradiation techniques, especially in the anterior-to-posterior direction. The 3D TBI was advantageous, owing to its uniform dose delivery as well as its efficient treatment procedure.

  5. Perceptual and Brain Response to Odors Is Associated with Body Mass Index and Postprandial Total Ghrelin Reactivity to a Meal.

    Science.gov (United States)

    Sun, Xue; Veldhuizen, Maria G; Babbs, Amanda E; Sinha, Rajita; Small, Dana M

    2016-03-01

    Animal studies have shown that olfactory sensitivity is greater when fasted than when fed. However, human research has generated inconsistent results. One possible explanation for these conflicting findings is metabolic health. Many metabolic peptides, including ghrelin, are moderated by adiposity and influence olfaction and olfactory-guided behaviors. We tested whether the effect of a meal on the perceived intensity of suprathreshold chemosensory stimuli is influenced by body mass index and/or metabolic response to a meal. We found that overweight or obese (n = 13), but not healthy weight (n = 20) subjects perceived odors, but not flavored solutions, as more intense when hungry than when sated. This effect was correlated with reduced postprandial total ghrelin suppression (n = 23) and differential brain response to odors in the cerebellum, as measured with functional magnetic resonance imaging. In contrast, it was unrelated to circulating leptin, glucose, insulin, triglycerides, or free fatty acids; or to odor pleasantness or sniffing (n = 24). These findings demonstrate that the effect of a meal on suprathreshold odor intensity perception is associated with metabolic measures such as body weight and total ghrelin reactivity, supporting endocrine influences on olfactory perception. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Total body propofol clearance (TBPC) after living-donor liver transplantation (LDLT) surgery is decreased in patients with a long warm ischemic time.

    Science.gov (United States)

    Al-Jahdari, Wael S; Kunimoto, Fumio; Saito, Shigeru; Yamamoto, Koujirou; Koyama, Hiroshi; Horiuchi, Ryuya; Goto, Fumio

    2006-01-01

    Metabolic capacity after liver transplant surgery may be affected by the graft size and by hepatic injury during the surgery. This study was carried out to investigate the postoperative total body propofol clearance (TBPC) in living-donor liver transplantation (LDLT) patients and to investigate the major factors that contribute to decreased postoperative TBPC in LDLT patients. Fourteen patients scheduled for LDLT were included in this study. Propofol was administered at a rate of 2.0 mg.kg(-1).h(-1) as a sedative in the intensive care unit (ICU) setting. To calculate TBPC, propofol arterial blood concentration was measured by HPLC. Five variables were selected as factors affecting postoperative TBPC; bleeding volume (BLD), warm ischemic time (WIT), cold ischemic time (CIT), graft weight/standard liver volume ratio (GW/SLV), and portal blood flow after surgery (PBF). After factor analysis of six variables, including TBPC, varimax rotation was carried out, and this yielded three interpretable factors that accounted for 75.5% of the total variance in the data set. TBPC, WIT, CIT, and BLD were loaded on the first factor, PBF on the second factor, and GW/SLV on the third factor. The adjusted correlation coefficient between TBPC and WIT showed the highest value (r = -0.61) in the first factor. The LDLT patients were divided into two groups according to WIT; group A (WIT > 100 min) and group B (WIT < 100 min). Mean TBPC values in group A and group B were 14.6 +/- 2.1 and 28.5 +/- 4.1 ml.kg(-1).min(-1), respectively (P < 0.0001). These data suggest that LDLT patients with a long WIT have a risk of deteriorated drug metabolism.

  7. Whole body retention of 99mTc-diphosphonate. Relation to bio-chemical indices of bone turnover and to total body calcium

    International Nuclear Information System (INIS)

    Thomsen, K.; Johansen, J.; Nilas, L.; Christiansen, C.

    1987-01-01

    Whole body retention (WBR) and urinary excretion (UE) of 99m Te-diphosphonate were determined in 161 healthy adults and the results were compared to accepted biochemical markers of bone turnover. WBR was corrected for total body bone mineral (TBBM) and UE from forearm bone mineral content (BMC). Both uncorrected and corrected retention measurements were highly significantly correlated to the biochemical markers (P<0.001), but the r values were low (0.22-0.64). All bone turnover variables demonstrated considerably higher levels of bone turnover in postmenopausal women than in premenopausal women (P<0.001), whereas the variables were unchanged with age in men. The correction of WBR for TBBM and UE for BMC increased the validity of the retention methods and the two calculations gave exactly the same results on a group basis, both demonstrating significantly higher bone turnover in women than in men in each age group (P<0.05-P<0.001). All the turnover variables were measured in a group of perimenopausal women (n=33). The data clearly demonstrated that bone turnover is menopause dependent, whereas age in itself is of minor significance. (orig.)

  8. Rates and timing of vertical-axis block rotations across the Sierra Nevada-Walker Lane transition in the Bodie Hills

    Science.gov (United States)

    Rood, D. H.; Herman, S.; Burbank, D.; Bogue, S.

    2008-12-01

    We use paleomagnetic data from Tertiary volcanic rocks to address the rates and timing of vertical-axis block rotation across the Sierra Nevada-Walker Lane transition in the Bodie Hills, California/Nevada. In zones of continental deformation, block rotations are an important mechanism for permanent stain accommodation, and thus may be crucial to testing geodetic block models and resolving geologic-geodetic slip discrepancies. In our study, data included in the paleomagetic site means are high quality AF demagnetization results (least squared fits that generally include 5-7 points with MAD values less than 1). Thermal demagnetization results match the AF directions, and both thermal demag and rockmag results indicate strong ChRM, mostly carried by single domain magnetite. The site means used to calculate the VGPs all have a95 values less than 10 (mostly 2-5) and include 6-11 sites each. Each site (and thus site mean) has a reasonably well-known structural correction. The VGP scatter values range from 12 to 16 degrees, indicating that they include appropriate secular variation. The mean declinations and 95 percent confidence limits for each VGP timeslice are statistically distinct from one another (71 ± 9, 39 ± 13, and 11 ± 11 degrees). The slope of a linear regression fit to the age versus declination data gives a rate of vertical axis block rotation of approximately 3-4 degrees/Myr. Fitting two separate lines to the age vs. declination data would indicate an increase in the rates of rotation since ~10 Ma. Two possible interpretations of the data are: (1) the rotations began during or before the Middle Miocene, or (2) rates of rotation were high initially (e.g. ~10 Ma) and decelerated until the Pliocene. These data have implications for the (1) timing and spatial extent of distributed strain accumulation related to the initiation of the San Andreas Fault-Eastern California Shear Zone-Walker Lane transform plate boundary, (2) transfer of transform plate boundary

  9. Cone beam CT-based set-up strategies with and without rotational correction for stereotactic body radiation therapy in the liver.

    Science.gov (United States)

    Bertholet, Jenny; Worm, Esben; Høyer, Morten; Poulsen, Per

    2017-06-01

    Accurate patient positioning is crucial in stereotactic body radiation therapy (SBRT) due to a high dose regimen. Cone-beam computed tomography (CBCT) is often used for patient positioning based on radio-opaque markers. We compared six CBCT-based set-up strategies with or without rotational correction. Twenty-nine patients with three implanted markers received 3-6 fraction liver SBRT. The markers were delineated on the mid-ventilation phase of a 4D-planning-CT. One pretreatment CBCT was acquired per fraction. Set-up strategy 1 used only translational correction based on manual marker match between the CBCT and planning CT. Set-up strategy 2 used automatic 6 degrees-of-freedom registration of the vertebrae closest to the target. The 3D marker trajectories were also extracted from the projections and the mean position of each marker was calculated and used for set-up strategies 3-6. Translational correction only was used for strategy 3. Translational and rotational corrections were used for strategies 4-6 with the rotation being either vertebrae based (strategy 4), or marker based and constrained to ±3° (strategy 5) or unconstrained (strategy 6). The resulting set-up error was calculated as the 3D root-mean-square set-up error of the three markers. The set-up error of the spinal cord was calculated for all strategies. The bony anatomy set-up (2) had the largest set-up error (5.8 mm). The marker-based set-up with unconstrained rotations (6) had the smallest set-up error (0.8 mm) but the largest spinal cord set-up error (12.1 mm). The marker-based set-up with translational correction only (3) or with bony anatomy rotational correction (4) had equivalent set-up error (1.3 mm) but rotational correction reduced the spinal cord set-up error from 4.1 mm to 3.5 mm. Marker-based set-up was substantially better than bony-anatomy set-up. Rotational correction may improve the set-up, but further investigations are required to determine the optimal correction

  10. In vivo dosimetry with semiconducting diodes for dose verification in total-body irradiation. A 10-year experience

    International Nuclear Information System (INIS)

    Ramm, U.; Licher, J.; Moog, J.; Scherf, C.; Kara, E.; Boettcher, H.D.; Roedel, C.; Mose, S.

    2008-01-01

    Background and purpose: for total-body irradiation (TBI) using the translation method, dose distribution cannot be computed with computer-assisted three-dimensional planning systems. Therefore, dose distribution has to be primarily estimated based on CT scans (beam-zone method) which is followed by in vivo measurements to ascertain a homogeneous dose delivery. The aim of this study was to clinically establish semiconductor probes as a simple and fast method to obtain an online verification of the dose at relevant points. Patients and methods: in 110 consecutively irradiated TBI patients (12.6 Gy, 2 x 1.8 Gy/day), six semiconductor probes were attached to the body surface at dose-relevant points (eye/head, neck, lung, navel). The mid-body point of the abdomen was defined as dose reference point. The speed of translation was optimized to definitively reach the prescribed dose in this point. Based on the entrance and exit doses, the mid-body doses at the other points were computed. The dose homogeneity in the entire target volume was determined comparing all measured data with the dose at the reference point. Results: after calibration of the semiconductor probes under treatment conditions the dose in selected points and the dose homogeneity in the target volume could be quantitatively specified. In the TBI patients, conformity of calculated and measured doses in the given points was achieved with small deviations of adequate accuracy. The data of 80% of the patients are within an uncertainty of ± 5%. Conclusion: during TBI using the translation method, dose distribution and dose homogeneity can be easily controlled in selected points by means of semiconductor probes. Semiconductor probes are recommended for further use in the physical evaluation of TBI. (orig.)

  11. The mechanism of 'solid-body' rotation of superfluid and normal components in the process of separation into layers of the over saturated 3He-4He solution

    International Nuclear Information System (INIS)

    Pashitskij, Eh.A.; Mal'nev, V.N.; Naryshkin, R.A.

    2005-01-01

    It is shown that unstable hydrodynamic vortices may be formed inside subcritical nuclei of separation in the normal component of the decaying over saturated 3 He- 4 He solution. We consider the mechanism of drag of the superfluid component of the 3 He- 4 He solution by the normal component into the 'solid-body' rotation due to the Hall-Vinen-Bekarevich-Khalatnikov forces in the equations of two-fluid hydrodynamics, resulting in the formation of quantized vortices. An increase in the average density of the quantized vortices may accelerate the process of heterogeneous decomposition of the 3 He- 4 He solution

  12. A linearized system describing stationary incompressible viscous flow around rotating and translating bodies: improved decay estimates of the velocity and its gradient

    Czech Academy of Sciences Publication Activity Database

    Deuring, P.; Kračmar, S.; Nečasová, Šárka

    2011-01-01

    Roč. 2011, - (2011), s. 351-361 ISSN 1078-0947. [8th AIMS International Conference. Dresden, 25.05.2010-28.05.2010] R&D Projects: GA AV ČR IAA100190804; GA ČR(CZ) GAP201/11/1304 Institutional research plan: CEZ:AV0Z10190503 Keywords : viscous incompressible flow * rotating body * fundamental solution Subject RIV: BA - General Mathematics Impact factor: 0.913, year: 2011 http://aimsciences.org/journals/displayArticlesnew.jsp?paperID=6978

  13. A Motivational Model of Physical Education and Links to Enjoyment, Knowledge, Performance, Total Physical Activity and Body Mass Index

    Directory of Open Access Journals (Sweden)

    Arto Gråstén, Anthony Watt

    2017-09-01

    Full Text Available The present paper examined the full sequence of the Hierarchical Model of Motivation in physical education (PE including motivational climate, basic psychological needs, intrinsic motivation, and related links to contextual enjoyment, knowledge, performance, and total moderate to vigorous physical activity (MVPA. Gender differences and correlations with body mass index (BMI were also analyzed. Cross-sectional data was represented by self-reports and objective assessments of 770 middle school students (52% of girls in North-East Finland. The results showed that task-involving climate in girls’ PE classes was related to enjoyment and knowledge through physical competence and intrinsic motivation, whereas task-involving climate was associated with enjoyment and knowledge via competence and autonomy, and total MVPA via autonomy, intrinsic motivation, and knowledge within boys. This may indicate that girls and boys perceive PE classes in a different way. Graded PE assessments appeared to be essential in motivating both girls and boys to participate in greater total MVPA, whereas BMI was negatively linked with competence and social relatedness only among girls. Although, the current and previous empirical findings supported task-involving teaching methods in PE, in some cases, ego-involving climate should be considered. Therefore, both task- and ego-involving teaching practices can be useful ways of developing preferred behaviors in PE classes.

  14. The Association of Serum Total Peptide YY (PYY) with Obesity and Body Fat Measures in the CODING Study.

    Science.gov (United States)

    Cahill, Farrell; Ji, Yunqi; Wadden, Danny; Amini, Peyvand; Randell, Edward; Vasdev, Sudesh; Gulliver, Wayne; Sun, Guang

    2014-01-01

    PYY is an appetite suppressing hormone. Low circulating PYY has been linked to greater BMI. However data is controversial and this association has not been verified in large human populations. The purpose of this study was to investigate if fasting serum total PYY is associated with obesity status and/or adiposity at the population level. A total of 2094 subjects (Male-523, Female-1571) participated in this investigation. Total PYY was measured in fasting serum by enzyme-linked immunosorbent assay. Obesity status (NW-normal-weight, OW-overweight and OB-obese) was determined by the Bray Criteria according to body fat percentage measured by dual-energy x-ray absorptiometry and the WHO criteria according to BMI. One-way ANOVA and multiple regression was used to assess the adiposity-specific association between PYY and the following; weight, BMI, waist-circumference, hip-circumference, waist-hip ratio, percent body fat (%BF), trunk fat (%TF), android fat (%AF) and gynoid fat (%GF). PYY was not significantly different among NW, OW and OB groups defined by neither %BF nor BMI for both men and women. However among women, fasting PYY was positively associated with adiposity measures. Women with the highest (Top 33%) waist-circumference, %BF and %TF had significantly higher PYY (10.5%, 8.3% and 9.2% respectively) than women with the lowest (Bottom 33%). Age, smoking, medication use and menopause were all positively associated with PYY levels in women but not in men. To our knowledge this is the largest population based study, with the most comprehensive analysis and measures of confounding factors, to explore the relationship of circulating PYY with obesity. Contrary to initial findings in the literature we discovered that PYY was positively associated with body fat measures (waist-circumference, %BF and %TF) in women. Although the effect size of the positive association of PYY with obesity in women is small, and potentially negligible, it may in fact represent a protective

  15. General circular velocity relation of a test particle in a 3D gravitational potential: application to the rotation curves analysis and total mass determination of UGC 8490 and UGC 9753

    Science.gov (United States)

    Repetto, P.; Martínez-García, E. E.; Rosado, M.; Gabbasov, R.

    2018-06-01

    In this paper, we derive a novel circular velocity relation for a test particle in a 3D gravitational potential applicable to every system of curvilinear coordinates, suitable to be reduced to orthogonal form. As an illustration of the potentiality of the determined circular velocity expression, we perform the rotation curves analysis of UGC 8490 and UGC 9753 and we estimate the total and dark matter mass of these two galaxies under the assumption that their respective dark matter haloes have spherical, prolate, and oblate spheroidal mass distributions. We employ stellar population synthesis models and the total H I density map to obtain the stellar and H I+He+metals rotation curves of both galaxies. The subtraction of the stellar plus gas rotation curves from the observed rotation curves of UGC 8490 and UGC 9753 generates the dark matter circular velocity curves of both galaxies. We fit the dark matter rotation curves of UGC 8490 and UGC 9753 through the newly established circular velocity formula specialized to the spherical, prolate, and oblate spheroidal mass distributions, considering the Navarro, Frenk, and White, Burkert, Di Cintio, Einasto, and Stadel dark matter haloes. Our principal findings are the following: globally, cored dark matter profiles Burkert and Einasto prevail over cuspy Navarro, Frenk, and White, and Di Cintio. Also, spherical/oblate dark matter models fit better the dark matter rotation curves of both galaxies than prolate dark matter haloes.

  16. Earth Rotation

    Science.gov (United States)

    Dickey, Jean O.

    1995-01-01

    The study of the Earth's rotation in space (encompassing Universal Time (UT1), length of day, polar motion, and the phenomena of precession and nutation) addresses the complex nature of Earth orientation changes, the mechanisms of excitation of these changes and their geophysical implications in a broad variety of areas. In the absence of internal sources of energy or interactions with astronomical objects, the Earth would move as a rigid body with its various parts (the crust, mantle, inner and outer cores, atmosphere and oceans) rotating together at a constant fixed rate. In reality, the world is considerably more complicated, as is schematically illustrated. The rotation rate of the Earth's crust is not constant, but exhibits complicated fluctuations in speed amounting to several parts in 10(exp 8) [corresponding to a variation of several milliseconds (ms) in the Length Of the Day (LOD) and about one part in 10(exp 6) in the orientation of the rotation axis relative to the solid Earth's axis of figure (polar motion). These changes occur over a broad spectrum of time scales, ranging from hours to centuries and longer, reflecting the fact that they are produced by a wide variety of geophysical and astronomical processes. Geodetic observations of Earth rotation changes thus provide insights into the geophysical processes illustrated, which are often difficult to obtain by other means. In addition, these measurements are required for engineering purposes. Theoretical studies of Earth rotation variations are based on the application of Euler's dynamical equations to the problem of finding the response of slightly deformable solid Earth to variety of surface and internal stresses.

  17. Regeneration of the epidermis and basement membrane of the planarian Dugesia japonica after total-body x irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hori, I.

    1979-03-01

    Fresh-water planarians were studied to examine effects of x rays on regeneration of the epidermis and basement membrane. During early stages of regeneration, free rhabdite-forming cells were associated with the wound epidermis and recruited it. In later stages, however, a gradual degeneration occurred in the epidermis and cells undergoing epithelization decreased in number. Eventually epidermal cells on the wound surface appeared necrotic as evidenced by pyknotic nuclei and vacuolized dense cytoplasm. The entire basement membrane could not be reconstituted in any stage after wounding though its precursor-like material was secreted in the interspace between epidermis and parenchyma. Morphological changes in extracellular products and in the cells surrounding the products suggest that epidermal cells which have covered the wound surface synthesize precursors of the basement membrane. Possible factors of a characteristic perturbation in epithelization and basement membrane formation after total-body irradiation are discussed.

  18. Radiobiological basis of total body irradiation with different dose rate and fractionation: repair capacity of hemopoietic cells

    International Nuclear Information System (INIS)

    Song, C.W.; Kim, T.H.; Khan, F.M.; Kersey, J.H.; Levitt, S.H.

    1981-01-01

    Total body irradiation (TBI) followed by bone marrow transplantation is being used in the treatment of malignant or non-malignant hemopoietic disorders. It has been believed that the ability of hemopoietic cells to repair sublethal radiation damage is negligible. Therefore, several schools of investigators suggested that TBI in a single exposure at extremely low dose rate (5 rad/min) over several hours, or in several fractions in 2-3 days, should yield a higher therapeutic gain, as compared with a single exposure at a high dose rate (26 rad/min). We reviewed the existing data in the literature, in particular, the response of hemopoietic cells to fractionated doses of irradiation and found that the repair capacity of both malignant and non-malignant hemopoietic cells might be greater than has been thought. It is concluded that we should not underestimate the ability of hemopoietic cells to repair sublethal radiation damage in using TBI

  19. The Basel experience with total body irradiation for conditioning patients with acute leukemia for allogenic bone marrow transplantation

    International Nuclear Information System (INIS)

    Speck, B.; Cornu, P.; Nissen, C.; Gratwohl, A.; Sartorius, J.

    1979-01-01

    We are reporting our experience with 13 patients suffering from end stage acute leukemia that were prepared for allogeneic bone marrow transplantation by combined chemotherapy followed by high dose cyclophosphamide (Cy) and total body irradiation (TBI). Only one patient became a long term survivor. Of the evaluable 12 patients, 6 died of interstitial pneumonia, 4 of GvH and 1 of recurrent leukemia. We conclude that adding combined chemotherapy to the standard conditioning program with Cy and TBI probably increases the risk of developing fatal interstitial pneumonia without eliminating the risk of recurrent leukemia. We suggest that allogenic marrow grafts should be performed earlier in the course of refractory acute leukemias, because in patients with end stage disease its chances of being curative are small

  20. Late complications following total-body irradiation and bone marrow rescue in mice: predominance of glomerular nephropathy and hemolytic anemia

    International Nuclear Information System (INIS)

    Down, J.D.; Berman, A.J.; Mauch, P.; Warhol, M.

    1990-01-01

    Late mortality and pathology were assessed in various mouse strains following total-body irradiation (TBI) and bone marrow transplantation. Long-term survival data revealed both radiation dose- and strain-dependent onset of mortality between 1 and 2 years post-treatment. Renal damage appeared to have contributed to the late mortality in most treatment groups as shown by glomerular lesions, elevated blood urea nitrogen and an accompanying fall in hematocrit. Hemolysis was deduced to be the major cause of anemia, as concluded from results of 51 Cr-labeled erythrocyte survival. No decrease in erythropoiesis was evident as seen from spleen and bone marrow 59 Fe uptake. These findings are together consistent with the manifestation of a hemolytic uremic syndrome (HUS) with kidney glomeruli representing the principal sites of injury responsible for both renal dysfunction and microangiopathic hemolysis. (author)

  1. Protective effect of Asparagus racemosus root extract against lethal total - body electron beam radiation induced damage in Swiss albino mice

    International Nuclear Information System (INIS)

    Sharmila, K.P.; Bhandary, B. Satheesh Kumar; Suchetha Kumari, N.; Bhat, Vadish S.; Shetty, Jayaram; Peter, Alex John; Jose, Jerish M.; Fernandes, Ronald

    2016-01-01

    To investigate the protective effect of Asparagus Racemosus Root ethanolic extract (ARE) in Swiss albino mice against acute lethal total - body Electron beam irradiation. Swiss Albino mice were used for the assessment of radiation induced sickness and 30 day survival analysis. Survival studies were determined using the Kaplan-Meier survival curves. The maximum survival was observed in the experimental mice pretreated with 200 mg/kg.b.wt. of ARE which also reduced the radiation sickness characteristics. This dose was considered as an optimal dose for radioprotection. Treatment of mice with ARE before irradiation delayed the onset of mortality as compared with the untreated irradiated controls. Present findings demonstrate the potential of ARE in mitigating radiation-induced mortality, which may be attributed to its free radical scavenging and increased antioxidant potential

  2. Late complications following total-body irradiation and bone marrow rescue in mice: predominance of glomerular nephropathy and hemolytic anemia

    Energy Technology Data Exchange (ETDEWEB)

    Down, J.D.; Berman, A.J.; Mauch, P. (Harvard Medical School, Boston, MA (USA)); Warhol, M. (Pennsylvania Hospital, Philadelphia, PA (USA). Dept. of Pathology); Yeap, B. (Dana Farber Cancer Inst., Boston, MA (USA))

    1990-03-01

    Late mortality and pathology were assessed in various mouse strains following total-body irradiation (TBI) and bone marrow transplantation. Long-term survival data revealed both radiation dose- and strain-dependent onset of mortality between 1 and 2 years post-treatment. Renal damage appeared to have contributed to the late mortality in most treatment groups as shown by glomerular lesions, elevated blood urea nitrogen and an accompanying fall in hematocrit. Hemolysis was deduced to be the major cause of anemia, as concluded from results of {sup 51}Cr-labeled erythrocyte survival. No decrease in erythropoiesis was evident as seen from spleen and bone marrow {sup 59}Fe uptake. These findings are together consistent with the manifestation of a hemolytic uremic syndrome (HUS) with kidney glomeruli representing the principal sites of injury responsible for both renal dysfunction and microangiopathic hemolysis. (author).

  3. Regeneration of the epidermis and basement membrane of the planarian Dugesia japonica after total-body x irradiation

    International Nuclear Information System (INIS)

    Hori, I.

    1979-01-01

    Fresh-water planarians were studied to examine effects of x rays on regeneration of the epidermis and basement membrane. During early stages of regeneration, free rhabdite-forming cells were associated with the wound epidermis and recruited it. In later stages, however, a gradual degeneration occurred in the epidermis and cells undergoing epithelization decreased in number. Eventually epidermal cells on the wound surface appeared necrotic as evidenced by pyknotic nuclei and vacuolized dense cytoplasm. The entire basement membrane could not be reconstituted in any stage after wounding though its precursor-like material was secreted in the interspace between epidermis and parenchyma. Morphological changes in extracellular products and in the cells surrounding the products suggest that epidermal cells which have covered the wound surface synthesize precursors of the basement membrane. Possible factors of a characteristic perturbation in epithelization and basement membrane formation after total-body irradiation are discussed

  4. Hippophae leaf extract (SBL-1) countered radiation induced dysbiosis in jejunum of total body 60Cobalt gamma - irradiated mice

    International Nuclear Information System (INIS)

    Beniwal, C.S.; Madhu Bala

    2014-01-01

    Single dose of SBL-1 administered at the rate 30 mg/kg body weight (b.w.) 30 min prior to whole body 60 Co-gamma-irradiation at lethal dose (10 Gy), rendered >90% survival in comparison to zero survival in the non-SBL-1 treated 60 Co-gamma-irradiated (10 Gy) mice population (J Herbs Spices Med Plants, 2009; 15(2): 203-215). Present study investigated the effect of SBL-1 on jejunal microbiota in lethally irradiated mice. Study was performed with inbred Swiss albino Strain 'A' male mice (age 9 weeks) weighing 28±2 g. The animals were maintained under controlled environment at 26±2℃; 12 h light/dark cycle and offered standard animal food (Golden feed, Delhi) as well as tap water ad libitum. Metagenomic DNA was extracted, purified and quantified from jejunum of the mice. Universal primers (27f and 1492r) were used to amplify the 16S rRNA DNA from the metagenomic DNA. Amplicons were sequenced, vector contamination and chimeras were removed. The sequences (GenBank Accession No: KF681283 to KF681351) were taxonomically classified by using Sequence Match program, Ribosomal Database Project as well as by nucleotide-BLAST (E-value: 10, database: 16S rRNA gene sequences, Bacteria and Archea). Phylogenetic Tree was prepared using MEGA 5.2 package, using maximum likelihood algorithm after sequence alignment by MUSCLE. Thermus aquaticus was used as out-group to construct rooted tree. Branch stability was assessed by bootstrap analysis. Untreated animals and the animals treated with SBL-1 had 100% Lactobacillus; 60 Co gamma-irradiated animals had 55% Cohaesibacter (Alphaproteobacteria); 27% Mycoplasma (Tenericutes) and only 18% Lactobacillus; animals treated with SBL-1 prior to irradiation had 89% Lactobacillus and 11% Clostridium. This study demonstrated that treatment with SBL-1 at radioprotective doses before total body irradiation with lethal dose (10 Gy) countered the jejunal dysbiosis. (author)

  5. Effects of resistance or aerobic exercise training on total and regional body composition in sedentary overweight middle-aged adults.

    Science.gov (United States)

    Donges, Cheyne E; Duffield, Rob

    2012-06-01

    The purpose of this study was to examine the effects of 10 weeks of aerobic endurance training (AET), resistance exercise training (RET), or a control (CON) condition on absolute and relative fat mass (FM) or fat-free mass (FFM) in the total body (TB) and regions of interest (ROIs) of sedentary overweight middle-aged males and females. Following prescreening, 102 subjects underwent anthropometric measurements, dual-energy X-ray absorptiometry, and strength and aerobic exercise testing. Randomized subjects (male RET, n = 16; female RET, n = 19; male AET, n = 16; and female AET, n = 25) completed supervised and periodized exercise programs (AET, 30-50 min cycling at 70%-75% maximal heart rate; RET, 2-4 sets × 8-10 repetitions of 5-7 exercises at 70%-75% 1 repetition maximum) or a nonexercising control condition (male CON, n = 13 and female CON, n = 13). Changes in absolute and relative TB-FM and TB-FFM and ROI-FM and ROI-FFM were determined. At baseline, and although matched for age and body mass index, males had greater strength, aerobic fitness, body mass, absolute and relative TB-FFM and ROI-FFM, but reduced absolute and relative TB-FM and ROI-FM, compared with females (p FFM and reduced TB-FM more than did the female exercise groups (p FFM, thus resulting in a greater enhancement of relative FFM. Despite equivalent or greater responses to RET or AET by female subjects, the corresponding respective increases in FFM or reductions in FM were lower than those in males, indicating that a biased dose-response relationship exists between sexes following 10 weeks of exercise training.

  6. Acute central nervous system (CNS) toxicity of total body irradiation (TBI) measured using neuropsychological testing of attention functions

    International Nuclear Information System (INIS)

    Wenz, Frederik; Steinvorth, Sarah; Lohr, Frank; Hacke, Werner; Wannenmacher, Michael

    1999-01-01

    Purpose: The purpose of this study was to investigate acute normal tissue damage of low irradiation doses to the healthy, adult central nervous system (CNS) using neuropsychological testing of attention functions. Methods and Materials: Neuropsychological testing (IQ, attention [modified Trail-Making Test A, Digit Symbol Test, D2 Test, Wiener Determination Machine]) was used to examine 40 patients (43 ± 10 years) before and immediately after the first fraction (1.2 Gy) of hyperfractionated total body irradiation (TBI) at the University of Heidelberg. The patients received antiemetic premedication. Test results are given as mean percentiles ± standard deviation, with 50 ± 34 being normal. Thirty-eight control patients (53 ± 15 years) were studied to quantify the influence of hospitalization, stress, and repeated testing. Results: The patients showed normal baseline test results (IQ = 101 ± 14, attention = 54 ± 28) and no decrease in test results after 1.2 Gy TBI. Attention functions improved (66 ± 25) corresponding to a practice effect of repeated testing that was seen in the control group, although alternate versions of the tests were used (IQ = 104 ± 10, attention before = 42 ± 29, attention after = 52 ± 31). Conclusion: Our data show no deterioration of neuropsychologic test results acutely after 1.2 Gy whole body exposure in adult patients without CNS disease receiving antiemetic medication

  7. Influence of Posture and Frequency Modes in Total Body Water Estimation Using Bioelectrical Impedance Spectroscopy in Boys and Adult Males

    Directory of Open Access Journals (Sweden)

    Masaharu Kagawa

    2014-05-01

    Full Text Available The aim of the study was to examine differences in total body water (TBW measured using single-frequency (SF and multi-frequency (MF modes of bioelectrical impedance spectroscopy (BIS in children and adults measured in different postures using the deuterium (2H dilution technique as the reference. Twenty-three boys and 26 adult males underwent assessment of TBW using the dilution technique and BIS measured in supine and standing positions using two frequencies of the SF mode (50 kHz and 100 kHz and the MF mode. While TBW estimated from the MF mode was comparable, extra-cellular fluid (ECF and intra-cellular fluid (ICF values differed significantly (p < 0.01 between the different postures in both groups. In addition, while estimated TBW in adult males using the MF mode was significantly (p < 0.01 greater than the result from the dilution technique, TBW estimated using the SF mode and prediction equation was significantly (p < 0.01 lower in boys. Measurement posture may not affect estimation of TBW in boys and adult males, however, body fluid shifts may still occur. In addition, technical factors, including selection of prediction equation, may be important when TBW is estimated from measured impedance.

  8. Restauração do centro de rotação na artroplastia total do quadril minimamente invasiva Restoration of the rotation center in minimally-invasive total hip replacement

    Directory of Open Access Journals (Sweden)

    José Ricardo Negreiros Vicente

    2009-01-01

    Full Text Available OBJETIVO: Nosso objetivo foi avaliar a dificuldade de se obter uma restauração satisfatória do centro de rotação , assim como, um bom posicionamento acetabular, no acesso minimamente invasivo posterior nas artroplastias totais do quadril não cimentadas. METODOS: Realizamos um estudo não randomizado comparativo prospectivo, com 64 pacientes submetidos a artroplastia total do quadril com o acesso minimamente invasivo posterior, realizado por um único cirurgião. Todos os pacientes incluídos no estudo apresentavam migração superior e lateral do centro de rotação do quadril em comparação com o quadril contralateral.Os critérios de exclusão foram: fratura do colo femoral, quadris displásicos tipos 2,3 e 4 segundo a classificação de Crowe e osteoartrose do quadril contralateral. Entre os 64 pacientes, 39 apresentaram um planejamento acetabular radiográfico igual ou menor que 50mm e 25 pacientes igual ou maior que 52 mm. Consideramos bom resultado os seguintes quesitos: inclinação acetabular entre 35 e 50 graus, componente acetabular coincidente com a estimativa pré-operatória com contato nas três zonas de DeLee e Charnley, abaixamento e medialização do centro de rotação em relação as medidas pré-operatórias e uma discrepância final do membro menor que 10 mm. RESULTADOS: Uma melhor restauração do centro de rotação foi observada nos pacientes com componentes acetabulares iguais ou menores que 50, p=0.04. Devemos destacar duas situações de risco ao usarmos o acesso minimamente invasivo posterior: colocação do componente acetabular em posição vertical ou lateral devido a preparo e fresagem insuficientes do osso hospedeiro, com piora do contato do implante na zona 1 acetabular. CONCLUSÃO: Propomos em pacientes cujo acetábulo previsto seja igual ou maior que 52 mm, o uso de acessos cirúrgicos convencionais.PURPOSE: Our aim was to evaluate the challenges in obtaining a successful restoration of the rotation

  9. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    Energy Technology Data Exchange (ETDEWEB)

    Karakas, Hakki Muammer [Inonu University Medical Faculty, Turgut Ozal Medical Center, Department of Radiology, Malatya (Turkey); Celbis, Osman [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Forensic Medicine, Malatya (Turkey); Harma, Ahmet [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Orthopaedics and Traumatology, Malatya (Turkey); Alicioglu, Banu [Trakya University Medical Faculty, Department of Radiology, Edirne (Turkey); Trakya University Health Sciences Institute, Department of Anatomy, Edirne (Turkey)

    2011-05-15

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 {+-} 14.9 years) and 43 women (41.1 {+-} 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 {+-} 12.6 mm (77-138 mm) in men and 104.7 {+-} 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  10. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    International Nuclear Information System (INIS)

    Karakas, Hakki Muammer; Celbis, Osman; Harma, Ahmet; Alicioglu, Banu

    2011-01-01

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 ± 14.9 years) and 43 women (41.1 ± 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 ± 12.6 mm (77-138 mm) in men and 104.7 ± 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  11. CT analysis of lung density changes in patients undergoing total body irradiation prior to bone marrow transplantation

    International Nuclear Information System (INIS)

    Lee, J.Y.; Shank, B.; Bonfiglio, P.; Reid, A.

    1984-01-01

    Sequential changes in lung density measured by CT are potentially sensitive and convenient monitors of lung abnormalities following total body irradiation (TBI). Methods have been developed to compare pre- and post-TBI CT of lung. The average local features of a cross-sectional lung slice are extracted from three peripheral regions of interest in the anterior, posterior, and lateral portions of the CT image. Also, density profiles across a specific region may be obtained. These may be compared first for verification of patient position and breathing status and then for changes between pre- and post-TBI. These may also be compared with radiation dose profiles through the lung. A preliminary study on 21 leukemia patients undergoing total body irradiation indicates the following: (a) Density gradients of patients' lungs in the antero-posterior direction show a marked heterogeneity before and after transplantation compared with normal lungs. The patients with departures from normal density gradients pre-TBI correlate with later pulmonary complications. (b) Measurements of average peripheral lung densities have demonstrated that the average lung density in the younger age group is substantially higher: pre-TBI, the average CT number (1,000 scale) is -638 +/- 39 Hounsfield unit (HU) for 0-10 years old and -739 +/- 53 HU for 21-40 years old. (c) Density profiles showed no post-TBI regional changes in lung density corresponding to the dose profile across the lung, so no differentiation of a radiation-specific effect has yet been possible. Computed tomographic density profiles in the antero-posterior direction are successfully used to verify positioning of the CT slice and the breathing level of the lung

  12. Serum angiotensin-converting enzyme (SACE) activity as an indicator of total body granuloma load and prognosis in sarcoidosis.

    Science.gov (United States)

    Muthuswamy, P P; Lopez-Majano, V; Ranginwala, M; Trainor, W D

    1987-09-01

    The relationship between the level of serum angiotensin converting enzyme (SACE) and the total body granuloma load in patients with sarcoidosis was studied in two groups using SACE levels and total body gallium67 scans. The study group consisted of 22 patients with SACE levels greater than or equal to 100 U/ml (EH-SACE group) and the control group consisted of 24 patients consecutively diagnosed to have sarcoidosis in a one year period with SACE level of less than 80 U/ml. The average number of organs involved in the EH-SACE group was 3.9 +/- 1 compared to 2.3 +/- 1 in the control group (p less than 0.0001). The incidence of extra pulmonary organ involvement in the EH-SACE group was 2.2 +/- 1 organs compared to 1.0 + 0.8 in the control group (p less than 0.0002). The SACE level was correlated with the number of organs involved for all patients with sarcoidosis (r = .55; p less than .0001). Following corticosteroid therapy for 39 +/- 41 weeks the SACE dropped to 64 +/- 45 units in the EH-SACE group. But it took only 13 +/- 10 weeks to normalize the SACE level to 27 +/- 9 units in the control group. The EH-SACE group patients were followed for 114 +/- 64 weeks and 73% of them still have active sarcoidosis requiring repeated cycles of corticosteroid therapy, while after 42 +/- 23 weeks of follow up only 10% of patients from the control group were still on therapy.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Relationship of total body fat mass to weight-bearing bone volumetric density, geometry, and strength in young girls.

    Science.gov (United States)

    Farr, Joshua N; Chen, Zhao; Lisse, Jeffrey R; Lohman, Timothy G; Going, Scott B

    2010-04-01

    Understanding the influence of total body fat mass (TBFM) on bone during the peri-pubertal years is critical for the development of future interventions aimed at improving bone strength and reducing fracture risk. Thus, we evaluated the relationship of TBFM to volumetric bone mineral density (vBMD), geometry, and strength at metaphyseal and diaphyseal sites of the femur and tibia of young girls. Data from 396 girls aged 8-13 years from the "Jump-In: Building Better Bones" study were analyzed. Bone parameters were assessed using peripheral quantitative computed tomography (pQCT) at the 4% and 20% distal femur and 4% and 66% distal tibia of the non-dominant leg. Bone parameters at the 4% sites included trabecular vBMD, periosteal circumference, and bone strength index (BSI), while at the 20% femur and 66% tibia, parameters included cortical vBMD, periosteal circumference, and strength-strain index (SSI). Multiple linear regression analyses were used to assess associations between bone parameters and TBFM, controlling for muscle cross-sectional area (MCSA). Regression analyses were then repeated with maturity, bone length, physical activity, and ethnicity as additional covariates. Analysis of covariance (ANCOVA) was used to compare bone parameters among tertiles of TBFM. In regression models with TBFM and MCSA, associations between TBFM and bone parameters at all sites were not significant. TBFM explained very little variance in all bone parameters (0.2-2.3%). In contrast, MCSA was strongly related (p<0.001) to all bone parameters, except cortical vBMD. The addition of maturity, bone length, physical activity, and ethnicity did not alter the relationship between TBFM and bone parameters. With bone parameters expressed relative to total body mass, ANCOVA showed that all outcomes were significantly (p<0.001) greater in the lowest compared to the middle and highest tertiles of TBFM. Although TBFM is correlated with femur and tibia vBMD, periosteal circumference, and

  14. Treatment of blastic transformation of chronic granulocytic leukemia by chemotherapy, total body irradiation and infusion of cryopreserved autologous marrow

    Energy Technology Data Exchange (ETDEWEB)

    Buckner, C D; Stewart, P; Clift, R A; Fefer, A; Neiman, P E; Singer, J; Storb, R; Thomas, E D [Washington Univ., Seattle (USA). School of Medicine; The United States Public Health Service Hospital; Providence Medical Center, and the Fred Hutchinson Cancer Research Center, Seattle, Washington, USA)

    1978-01-01

    We have previously reported attempts to reestablish the chronic phase of chronic granulocytic leukemia (CGL), in two patients with blastic transrormation, utilizing intensive therapy followed by the infusion of cryopreserved autologous marrow. This approach has now been attempted in a total of seven patients. Marrow was harvested on single or multiple occasions during the chronic phase of CGL and cryopreserved in 10% dimethylsulfoxide. All patients were treated with cyclophosphamide, 120 mg/kg, plus 1,000 rad of total body irradiation followed by infusion of stored marrow. Two patients failed to achieve marrow repopulation and died of infection after 29 and 48 days. Three patients had partial marrow recovery. Two of these achieved repopulation of myeloid, erythroid, and lymphoid elements but did not recover platelet function; one died of hemorrhage on day 55, and one died of cytomegalovirus interstitial pneumonitis on day 58. A third patient had delayed engraftment of all cell elements, most prominently lymphocytes, and died after 84 days of an iodopathic interstitial pneumonitis. Two patients achieved prompt and complete reestablishment of the chronic phase of CGL. One died on day 72 with a fungal pheumonitis and one developed blastic transformation within 4 months. These preliminary results indicate that this approach to the treatment of blastic transformation of CGL is feasible but difficult. Improvements in results may be achieved by more frequent storage of marrow and pheripheral blood stem cells and lymphocytes and further advances in pretransplant therapy.

  15. Booster irradiation to the spleen following total body irradiation. A new immunosuppressive approach for allogeneic bone marrow transplantation

    International Nuclear Information System (INIS)

    Lapidot, T.; Singer, T.S.; Salomon, O.; Terenzi, A.; Schwartz, E.; Reisner, Y.

    1988-01-01

    Graft rejection presents a major obstacle for transplantation of T cell-depleted bone marrow in HLA-mismatched patients. In a primate model, after conditioning exactly as for leukemia patients, it was shown that over 99% of the residual host clonable T cells are concentrated in the spleen on day 5 after completion of cytoreduction. We have now corroborated these findings in a mouse model. After 9-Gy total body irradiation (TBI), the total number of Thy-1.2+ cells in the spleen reaches a peak between days 3 and 4 after TBI. The T cell population is composed of both L3T4 (helper) and Lyt-2 (suppressor) T cells, the former being the major subpopulation. Specific booster irradiation to the spleen (5 Gy twice) on days 2 and 4 after TBI greatly enhances production of donor-type chimera after transplantation of T cell-depleted allogeneic bone marrow. Similar enhancement can be achieved by splenectomy on day 3 or 4 after TBI but not if splenectomy is performed 1 day before TBI or 1 day after TBI, strengthening the hypothesis that, after lethal TBI in mice, the remaining host T cells migrate from the periphery to the spleen. These results suggest that a delayed booster irradiation to the spleen may be beneficial as an additional immunosuppressive agent in the conditioning of leukemia patients, in order to reduce the incidence of bone marrow allograft rejection

  16. Long-term renal toxicity in children following fractionated total-body irradiation (TBI) before allogeneic stem cell transplantation (SCT)

    International Nuclear Information System (INIS)

    Gerstein, Johanna; Meyer, Andreas; Fruehauf, Joerg; Karstens, Johann H.; Bremer, Michael; Sykora, Karl-Walter

    2009-01-01

    Purpose: to retrospectively assess the incidence and time course of renal dysfunction in children (≤ 16 years) following total-body irradiation (TBI) before allogeneic stem cell transplantation (SCT). Patients and methods: between 1986 and 2003, 92 children (median age, 11 years; range, 3-16 years) underwent TBI before allogeneic SCT. 43 of them had a minimum follow-up of 12 months (median, 51 months; range, 12-186 months) and were included into this analysis. Conditioning regimen included chemotherapy and fractionated TBI with 12 Gy (n = 26) or 11.1 Gy (n = 17). In one patient, renal dose was limited to 10 Gy by customized renal shielding due to known nephropathy prior to SCt. Renal dysfunction was defined as an increase of serum creatinine > 1.25 times the upper limit of age-dependent normal. Results: twelve children (28%) experienced an episode of renal dysfunction after a median of 2 months (range, 1-10 months) following SCT. In all but one patient renal dysfunction was transient and resolved after a median of 8 months (range, 3-16 months). One single patient developed persistent renal dysfunction with onset at 10 months after SCT. None of these patients required dialysis. The actuarial 3-year freedom from persistent renal toxicity for children surviving > 12 months after SCt was 97.3%. Conclusion: the incidence of persistent renal dysfunction after fractionated TBI with total doses ≤ 12 Gy was very low in this analysis. (orig.)

  17. Evaluation of a semi-automated computer algorithm for measuring total fat and visceral fat content in lambs undergoing in vivo whole body computed tomography.

    Science.gov (United States)

    Rosenblatt, Alana J; Scrivani, Peter V; Boisclair, Yves R; Reeves, Anthony P; Ramos-Nieves, Jose M; Xie, Yiting; Erb, Hollis N

    2017-10-01

    Computed tomography (CT) is a suitable tool for measuring body fat, since it is non-destructive and can be used to differentiate metabolically active visceral fat from total body fat. Whole body analysis of body fat is likely to be more accurate than single CT slice estimates of body fat. The aim of this study was to assess the agreement between semi-automated computer analysis of whole body volumetric CT data and conventional proximate (chemical) analysis of body fat in lambs. Data were collected prospectively from 12 lambs that underwent duplicate whole body CT, followed by slaughter and carcass analysis by dissection and chemical analysis. Agreement between methods for quantification of total and visceral fat was assessed by Bland-Altman plot analysis. The repeatability of CT was assessed for these measures using the mean difference of duplicated measures. When compared to chemical analysis, CT systematically underestimated total and visceral fat contents by more than 10% of the mean fat weight. Therefore, carcass analysis and semi-automated CT computer measurements were not interchangeable for quantifying body fat content without the use of a correction factor. CT acquisition was repeatable, with a mean difference of repeated measures being close to zero. Therefore, uncorrected whole body CT might have an application for assessment of relative changes in fat content, especially in growing lambs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Busulfan and total body irradiation as antihematopoietic stem cell agents in the preparation of patients with congenital bone marrow disorders for allogenic bone marrow transplantation

    International Nuclear Information System (INIS)

    Parkman, R.; Rappeport, J.M.; Hellman, S.; Lipton, J.; Smith, B.; Geha, R.; Nathan, D.G.

    1984-01-01

    The capacity of busulfan and total body irradiation to ablate hematopoietic stem cells as preparation for the allogeneic bone marrow transplantation of patients with congenital bone marrow disorders was studied. Fourteen patients received 18 transplants; busulfan was used in the preparatory regimen of eight transplants and total body irradiation in the regimens of six transplants. Sustained hematopoietic ablation was achieved in six of eight patients prepared with busulfan and in all six patients prepared with total body irradiation. Three patients prepared with total body irradiation died with idiopathic interstitial pneumonitis, whereas no patients receiving busulfan developed interstitial pneumonitis. The optimal antihematopoietic stem cell agent to be used for the preparation of patients with congenital bone marrow disorder for bone marrow transplantation is not certain

  19. Model Reduction in Co-Rotated Multi-Body Dynamics Based on the Dual Craig-Bampton Method

    NARCIS (Netherlands)

    Weerathunge Kadawathagedara, S.T.; Rixen, D.J.

    2011-01-01

    A new reduction method for dynamical analsis of multi-body systems is presented in this paper. It fundamentally differs from the ones previously published in the way kinematical constraints are handled. Our approach is based on component mode synthesis, but the specificity of articulated mechanism,

  20. Influence of body mass index (BMI on functional improvements at 3 years following total knee replacement: a retrospective cohort study.

    Directory of Open Access Journals (Sweden)

    Paul Baker

    Full Text Available BACKGROUND: The number of patients presenting for total knee replacement who are classified as obese is increasing. The functional benefits of performing TKR in these patients are unclear. AIM: To assess the influence pre-operative body mass index has upon knee specific function, general health status and patient satisfaction at 3 years following total knee replacement. DESIGN: Retrospective comparative cohort study using prospectively collected data from an institutional arthroplasty register. METHODS: 1367 patients were assessed using the Western Ontario and McMaster University Osteoarthritis Index (WOMAC and Medical Outcomes Trust Short Form-36 (SF-36 scores supplemented by a validated measure of satisfaction pre-operatively and subsequently at 1,2 and 3 year post-operatively. Comparisons were made by dividing the cohort into 4 groups based on body mass index (BMI 18.5-25.0 kg/m(2 (n = 253;>25.0-30.0 kg/m(2 (n = 559;>30.0-35.0 kg/m(2 (n = 373;>35.0 kg/m(2 (n = 182. RESULTS: Despite lower pre-operative, 1 and 3 year WOMAC and SF-36 scores patients with the highest BMIs >35.0 kg/m(2 experienced similar improvements to patients with a 'normal' BMI (18.5-25.0 kg/m(2 at 1 year (Difference in WOMAC improvement = 0.0 (95%CI -5.2 to 5.2, p = 1.00 and this improvement was sustained at up to 3 years (Difference in 1 year to 3 year improvement = 2.2 (95%CI: -2.1 to 6.5, p = 1.00. This effect was also observed for the SF-36 mental and physical component scores. Despite equivalent functional improvements levels of satisfaction in the >35.0 kg/m(2 group were lower than for any other BMI group (>35.0 kg/m(2 = 84.6% satisfied versus 18.5-5.0 kg/m(2 = 93.3% satisfied,p = 0.01 as was the proportion of patients who stated they would have the operation again (>35.0 kg/m(2 = 69.6% versus 18.5-25.0 kg/m(2 = 82.2%,p = 0.01. CONCLUSION: Obese and morbidly obese patients gain as much functional benefit from

  1. Effect of Body Mass Index and Psychosocial Traits on Total Knee Replacement Costs in Patients with Osteoarthritis.

    Science.gov (United States)

    Waimann, Christian A; Fernandez-Mazarambroz, Rodrigo J; Cantor, Scott B; Lopez-Olivo, Maria A; Barbo, Andrea G; Landon, Glenn C; Siff, Sherwin J; Lin, Heather; Suarez-Almazor, Maria E

    2016-08-01

    Clinical and psychosocial attributes are associated with clinical outcomes after total knee replacement (TKR) surgery in patients with osteoarthritis (OA), but their relationship with TKR-related costs is less clear. Our objective was to evaluate the effect of clinical and psychosocial attributes on TKR costs. We conducted a 6-month prospective cohort study of patients with knee OA who underwent TKR. We examined baseline demographic, clinical [body mass index (BMI) and comorbidities], and psychosocial attributes (social support, locus of control, coping, depression, anxiety, stress, and self-efficacy); baseline and 6-month OA clinical outcomes [Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain and function]; and 6-month direct and indirect TKR-related costs. Multiple regression was performed to identify determinants of TKR-related costs. We included 212 patients; 66% were women, 71% were white, and the mean age was 65.2 years. The mean baseline WOMAC pain score was 55 (SD 19) and WOMAC function score was 54 (SD 20). Mean total TKR-related costs were US$30,831 (SD $9893). Multivariate regression analyses showed that increasing BMI and anxiety levels and decreasing levels of positive social interactions were associated with increased costs. A lower cost scenario with a lower range of normal BMI (19.5), highest positive social interaction, and no anxiety predicted TKR costs to be $22,247. Predicted costs in obese patients (BMI 36) with lowest positive social interaction and highest anxiety were $58,447. Increased baseline BMI, anxiety, and poor social support lead to higher TKR-related costs in patients with knee OA. Preoperative interventions targeting these factors may reduce TKR-related costs, and therefore be cost-effective.

  2. The Total Body Irradiation Schedule Affects Acute Leukemia Relapse After Matched T Cell–Depleted Hematopoietic Stem Cell Transplantation

    International Nuclear Information System (INIS)

    Aristei, Cynthia; Carotti, Alessandra; Palazzari, Elisa; Amico, Lucia; Ruggeri, Loredana; Perrucci, Elisabetta; Falcinelli, Lorenzo; Lancellotta, Valentina; Palumbo, Isabella; Falzetti, Franca; Aversa, Franco; Merluzzi, Mara; Velardi, Andrea; Martelli, Massimo Fabrizio

    2016-01-01

    Purpose: We sought to determine whether the total body irradiation (TBI) schedule affected outcome in patients with acute leukemia in complete remission who received T cell–depleted allogeneic hematopoietic stem cell transplantation from HLA identical siblings. Methods and Materials: The study recruited 55 patients (median age, 48 years; age range, 20-66 years; 30 men and 25 women; 34 with acute myeloid leukemia and 21 with acute lymphoid leukemia). Hyperfractionated TBI (HTBI) (1.2 Gy thrice daily for 4 days [for a total dose of 14.4 Gy] from day −12 to day −9) was administered to 29 patients. Single-dose TBI (STBI) (8 Gy, at a median dose rate of 10.7 cGy/min on day −9) was given to 26 patients. Results: All patients achieved primary, sustained engraftment with full donor-type chimerism. At 10 years, the overall cumulative incidence of transplant-related mortality was 11% (SE, ±0.1%). It was 7% (SE, ±0.2%) after HTBI and 15% (SE, ±0.5%) after STBI (P=.3). The overall cumulative incidence of relapse was 33% (SE, ±0.5). It was 13% (SE, ±0.5%) after HTBI and 46% (SE, ±1%) after STBI (P=.02). The overall probability of disease-free survival (DFS) was 59% (SE, ±7%). It was 67% (SE, ±0.84%) after HTBI and 37% (SE, ±1.4%) after STBI (P=.01). Multivariate analyses showed the TBI schedule was the only risk factor that significantly affected relapse and DFS (P=.01 and P=.03, respectively). Conclusions: In patients with acute leukemia, HTBI is more efficacious than STBI in eradicating minimal residual disease after HLA-matched T cell–depleted hematopoietic stem cell transplantation, thus affecting DFS.

  3. The Total Body Irradiation Schedule Affects Acute Leukemia Relapse After Matched T Cell–Depleted Hematopoietic Stem Cell Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Aristei, Cynthia, E-mail: cynthia.aristei@unipg.it [Radiation Oncology Section, Department of Surgery and Biomedical Sciences, University of Perugia and Perugia General Hospital, Perugia (Italy); Carotti, Alessandra [Division of Hematology and Clinical Immunology and Bone Marrow Transplant Program, Department of Medicine, Perugia General Hospital and University, Perugia (Italy); Palazzari, Elisa [Radiation Oncology Section, University of Perugia, Perugia (Italy); Amico, Lucia; Ruggeri, Loredana [Division of Hematology and Clinical Immunology and Bone Marrow Transplant Program, Department of Medicine, Perugia General Hospital and University, Perugia (Italy); Perrucci, Elisabetta; Falcinelli, Lorenzo [Radiation Oncology Division, Perugia General Hospital, Perugia (Italy); Lancellotta, Valentina [Radiation Oncology Section, University of Perugia, Perugia (Italy); Palumbo, Isabella [Radiation Oncology Section, Department of Surgery and Biomedical Sciences, University of Perugia and Perugia General Hospital, Perugia (Italy); Falzetti, Franca [Division of Hematology and Clinical Immunology and Bone Marrow Transplant Program, Department of Medicine, Perugia General Hospital and University, Perugia (Italy); Aversa, Franco [Hematology and Bone Marrow Transplant Unit, Department of Clinical and Experimental Medicine, Parma General Hospital and University, Parma (Italy); Merluzzi, Mara; Velardi, Andrea; Martelli, Massimo Fabrizio [Division of Hematology and Clinical Immunology and Bone Marrow Transplant Program, Department of Medicine, Perugia General Hospital and University, Perugia (Italy)

    2016-11-15

    Purpose: We sought to determine whether the total body irradiation (TBI) schedule affected outcome in patients with acute leukemia in complete remission who received T cell–depleted allogeneic hematopoietic stem cell transplantation from HLA identical siblings. Methods and Materials: The study recruited 55 patients (median age, 48 years; age range, 20-66 years; 30 men and 25 women; 34 with acute myeloid leukemia and 21 with acute lymphoid leukemia). Hyperfractionated TBI (HTBI) (1.2 Gy thrice daily for 4 days [for a total dose of 14.4 Gy] from day −12 to day −9) was administered to 29 patients. Single-dose TBI (STBI) (8 Gy, at a median dose rate of 10.7 cGy/min on day −9) was given to 26 patients. Results: All patients achieved primary, sustained engraftment with full donor-type chimerism. At 10 years, the overall cumulative incidence of transplant-related mortality was 11% (SE, ±0.1%). It was 7% (SE, ±0.2%) after HTBI and 15% (SE, ±0.5%) after STBI (P=.3). The overall cumulative incidence of relapse was 33% (SE, ±0.5). It was 13% (SE, ±0.5%) after HTBI and 46% (SE, ±1%) after STBI (P=.02). The overall probability of disease-free survival (DFS) was 59% (SE, ±7%). It was 67% (SE, ±0.84%) after HTBI and 37% (SE, ±1.4%) after STBI (P=.01). Multivariate analyses showed the TBI schedule was the only risk factor that significantly affected relapse and DFS (P=.01 and P=.03, respectively). Conclusions: In patients with acute leukemia, HTBI is more efficacious than STBI in eradicating minimal residual disease after HLA-matched T cell–depleted hematopoietic stem cell transplantation, thus affecting DFS.

  4. Rotation-induced YORP break-up of small bodies to produce post-main-sequence debris

    Science.gov (United States)

    Veras, D.; Jacobson, S. A.; Gänsicke, B. T.

    2017-09-01

    We hypothesize that the in situ break-up of small bodies such as asteroids spun to fission during the giant branch phases of stellar evolution provides an important contribution to the debris orbiting and ultimately polluting white dwarfs. The YORP (Yarkovsky-O'Keefe-Radviesvki-Paddock) effect, which arises from radiation pressure, accelerates the spin rate of asymmetric asteroids, which can eventually shear themselves apart. This pressure is maintained and enhanced around dying stars because the outward push of an asteroid due to stellar mass loss is insignificant compared to the resulting stellar luminosity increase. Consequently, giant star radiation will destroy nearly all bodies with radii in the range 100 m-10 km that survive their parent star's main-sequence lifetime within a distance of about 7 au; smaller bodies are spun apart to their strongest, competent components. This estimate is conservative and would increase for highly asymmetric shapes or incorporation of the inward drag due to giant star stellar wind. The resulting debris field, which could extend to thousands of au, may be perturbed by remnant planetary systems to reproduce the observed dusty and gaseous discs which accompany polluted white dwarfs.

  5. SU-F-T-327: Total Body Irradiation In-Vivo Dose Measurements Using Optically Stimulated Luminescence (OSL) NanoDots and Farmer Type Ion Chamber

    International Nuclear Information System (INIS)

    Kaur, H; Kumar, S; Sarkar, B; Ganesh, T; Giri, U; Jassal, K; Rathinamuthu, S; Gulia, G; Gopal, V; Mohanti, B; Munshi, A

    2016-01-01

    Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm"2 size with 45° collimator rotation at an SSD of 333.5 cm in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.

  6. SU-F-T-327: Total Body Irradiation In-Vivo Dose Measurements Using Optically Stimulated Luminescence (OSL) NanoDots and Farmer Type Ion Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, H; Kumar, S; Sarkar, B; Ganesh, T; Giri, U; Jassal, K; Rathinamuthu, S; Gulia, G; Gopal, V; Mohanti, B; Munshi, A [Fortis Memorial Research Institute, Gurgaon, Haryana (India)

    2016-06-15

    Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm{sup 2} size with 45° collimator rotation at an SSD of 333.5 cm in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.

  7. Water requirement and total body water estimation as affected by species, pregnancy and lactation using tritiated water

    International Nuclear Information System (INIS)

    Kamal, T.H.; El Banna, I.M.; Ayad, M.A.; Kotby, E.A.

    1978-01-01

    Radiotracer dilution technique was used to determine total body water (TBW) and the water turnover rate (WTR) estimate of water requirements in water buffaloe, Red Dannish cattle, fat tailed Osemi sheep and Camellus Dromedarius. Water buffaloes were found to have highest TBW, followed by camels, sheep and cattle in a descending order. The WTR ranking was highest for sheep followed by water buffaloe endurance to heat was found inseperable to high water usage, while in camels, an intericate water retention mechanism help animals to thrive in deserts. Fat tailled Osemi sheep and cattle failed to cope with high environmental temperature resulting in temporary dehydration. TBW was 17% and 6% higher in pregnant cattle and sheep than non-pregnant animals respectively, while there was no observed change in pregnant buffaloes. Water retention of pregnant cattle was associated with an appriciable increase in WTR, which was not noticable in buffaloe or sheep. Lactating buffaloe have had a higher TBW and WTR than lactating cattle. Milk yield per day during the period of measurement was higher in buffalo than cattle. Wallowing of buffalo in water pools during grazing, represents a behavioural adaptation for life in hot regions, aside of tendency for higher WTR with concomitant water retention

  8. Total body calcium by neutron activation analysis in normals and osteoporotic populations: a discriminator of significant bone mass loss

    International Nuclear Information System (INIS)

    Ott, S.M.; Murano, R.; Lewellen, T.K.; Nelp, W.B.; Chesnut, C.M.

    1983-01-01

    Measurements of total body calcium by neutron activation (TBC) in 94 normal individuals and 86 osteoporotic patients are reported. The ability of TBC to discriminate normal from osteoporotic females was evaluated with decision analysis. Bone mineral content (BMC) by single-photon absorptiometry was also measured. TBC was higher in males (range 826 to 1363 gm vs 537 to 1054 in