  1. SU-E-T-357: Electronic Compensation Technique to Deliver Total Body Dose

    Energy Technology Data Exchange (ETDEWEB)

    Lakeman, T [State University of New York at Buffalo, Buffalo, NY (United States); Wang, I; Podgorsak, M [State University of New York at Buffalo, Buffalo, NY (United States); Roswell Park Cancer Institute, Buffalo, NY (United States)

    2015-06-15

    Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient’s immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has conventionally been used to compensate for the varying thickness through the entire body in large-field TBI. The goal of this study is to pursue utilizing the modern electronic compensation technique to more accurately and efficiently deliver dose to patients in need of TBI. Methods: Treatment plans utilizing electronic compensation to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Each treatment plan includes two, specifically weighted, pair of opposed fields. One pair of open, large fields (collimator=45°), to encompass the patient’s entire anatomy, and one pair of smaller fields (collimator=0°) focused only on the thicker midsection of the patient. The optimal fluence for each one of the smaller fields was calculated at a patient specific penetration depth. Irregular surface compensators provide a more uniform dose distribution within the smaller opposed fields. Results: Dose-volume histograms (DVH) were calculated for the evaluating the electronic compensation technique. In one case, the maximum body doses calculated from the DVH were reduced from the non-compensated 195.8% to 165.3% in the electronically compensated plans, indicating a more uniform dose with the region of electronic compensation. The mean body doses calculated from the DVH were also reduced from the non-compensated 120.6% to 112.7% in the electronically compensated plans, indicating a more accurate delivery of the prescription dose. All calculated monitor units were well within clinically acceptable limits. Conclusion: Electronic compensation technique for TBI will not substantially increase the beam on time while it can significantly reduce the compensator

  2. A reviewed technique for total body electron therapy using a Varian Clinac 2100C/D high dose rate treatment beam facility

    International Nuclear Information System (INIS)

    Oliver, L.D.; Xuereb, E.M.A.; Last, V.; Hunt, P.B.; Wilfert, A.

    1996-01-01

    Our (Royal North Shore Hospital) most recent linear accelerator acquisition is a Varian Clinac 2100C/D which has a high dose rate (approximately 25Gy per minute at 1 metre) total body electron option. We investigated the physical characteristics of the electron beam to develop a suitable method of treatment for total body electron therapy. The useful electron beam width is defined as 80cm above and below the reference height. Measurements of the electron dose received from the two angled electron beams showed a critical dependence on the gantry angles. The treatment protocol uses ten different patient angles, fractionated into directly opposing fields and treated seuqentially each day. A full cycle of treatment is completed in five days. (author)

  3. Use of total body electrical conductivity (TOBEC) to determine total body water

    International Nuclear Information System (INIS)

    Cochran, W.; Wong, W.; Sheng, H.P.; Klein, P.; Klish, W.

    1986-01-01

    Total body electrical conductivity (TOBEC) has been introduced as a safe and rapid method to estimate body composition in infants and adults. Recently, a second generation instrument that operates in a scanning mode has been developed. A study was undertaken to calibrate this new instrument and to assess the feasibility of its use in estimating total body water. Six healthy adults, 3 males and 3 females, ranging in age from 25 to 57 years, and in weight from 43.3 to 104.7 kg were analyzed. Simultaneously, determinations of total body water were made by standard dilutional techniques using H 2 18 O. A baseline plasma sample was obtained and 60 mg 18 O/kg was given orally as H 2 18 O. Five hr later, a postdose plasma sample was obtained. The 18 O/ 16 O ratio in the plasma samples was determined as CO 2 by gas-isotope-ratio mass spectrometry and used to calculate the H 2 18 O volume of distribution. The total body water values ranged from 26.35 to 58.02 and represented 51 to 58% of body weight. There was good linear correlation between the total body water measurement and its phase average (TOBEC number) with a linear correlation coefficient of 0.998. The standard error of the estimate was 0.98. In addition to estimating fat and fat-free mass, the TOBEC method also estimates total body water with excellent correlation to physical dilutions methods

  4. Total body water and total body potassium in anorexia nervosa

    Energy Technology Data Exchange (ETDEWEB)

    Dempsey, D.T.; Crosby, L.O.; Lusk, E.; Oberlander, J.L.; Pertschuk, M.J.; Mullen, J.L.

    1984-08-01

    In the ill hospitalized patient with clinically relevant malnutrition, there is a measurable decrease in the ratio of the total body potassium to total body water (TBK/TBW) and a detectable increase in the ratio of total exchangeable sodium to total exchangeable potassium (Nae/Ke). To evaluate body composition analyses in anorexia nervosa patients with chronic uncomplicated semistarvation, TBK and TBW were measured by whole body K40 counting and deuterium oxide dilution in 10 females with stable anorexia nervosa and 10 age-matched female controls. The ratio of TBK/TBW was significantly (p less than 0.05) higher in anorexia nervosa patients than controls. The close inverse correlation found in published studies between TBK/TBW and Nae/Ke together with our results suggest that in anorexia nervosa, Nae/Ke may be low or normal. A decreased TBK/TBW is not a good indicator of malnutrition in the anorexia nervosa patient. The use of a decreased TBK/TBW ratio or an elevated Nae/Ke ratio as a definition of malnutrition may result in inappropriate nutritional management in the patient with severe nonstressed chronic semistarvation.

  5. Total body water and total body potassium in anorexia nervosa

    International Nuclear Information System (INIS)

    Dempsey, D.T.; Crosby, L.O.; Lusk, E.; Oberlander, J.L.; Pertschuk, M.J.; Mullen, J.L.

    1984-01-01

    In the ill hospitalized patient with clinically relevant malnutrition, there is a measurable decrease in the ratio of the total body potassium to total body water (TBK/TBW) and a detectable increase in the ratio of total exchangeable sodium to total exchangeable potassium (Nae/Ke). To evaluate body composition analyses in anorexia nervosa patients with chronic uncomplicated semistarvation, TBK and TBW were measured by whole body K40 counting and deuterium oxide dilution in 10 females with stable anorexia nervosa and 10 age-matched female controls. The ratio of TBK/TBW was significantly (p less than 0.05) higher in anorexia nervosa patients than controls. The close inverse correlation found in published studies between TBK/TBW and Nae/Ke together with our results suggest that in anorexia nervosa, Nae/Ke may be low or normal. A decreased TBK/TBW is not a good indicator of malnutrition in the anorexia nervosa patient. The use of a decreased TBK/TBW ratio or an elevated Nae/Ke ratio as a definition of malnutrition may result in inappropriate nutritional management in the patient with severe nonstressed chronic semistarvation

  6. Dosimetric methods and results of measurement for total body electron irradiation

    International Nuclear Information System (INIS)

    Feng Ningyuan; Yu Geng; Yu Zihao

    1987-01-01

    A modified 'STANFORD TSEI TECHNIQUE' e.g. dual angled gantry, 6 turntable angles and 12 fields was developed on PHILIPS SL 75-20 linear accelerator to treat mycosis fungoides. A plastic scatter screen, 5 mm in thickness was used to reduce the primary electron energy to 4 MeV in order to control treatment depth (d 80 approx.= 1.2 cm) and skin dose up to 89%. The X-ray contamination was at an acceptable level of 2%. This measurement which involved multiple dosimetric methods, showed that the distance between the scattor screen and the patient, within 10-30 cm, had no influence on PDD and the dose distribution on the body surface was reasonably homogeneous, but strongly dependent on the anatomic positions. For those sites which were located in the electron beam shadows, boosting irradiation might be necessary. The preliminary clinical trials indicated that this technique is valid and feasible

  7. Total body irradiation

    International Nuclear Information System (INIS)

    Novack, D.H.; Kiley, J.P.

    1987-01-01

    The multitude of papers and conferences in recent years on the use of very large megavoltage radiation fields indicates an increased interest in total body, hemibody, and total nodal radiotherapy for various clinical situations. These include high dose total body irradiation (TBI) to destroy the bone marrow and leukemic cells and provide immunosuppression prior to a bone marrow transplant, high dose total lymphoid irradiation (TLI) prior to bone marrow transplantation in severe aplastic anemia, low dose TBI in the treatment of lymphocytic leukemias or lymphomas, and hemibody irradiation (HBI) in the treatment of advanced multiple myeloma. Although accurate provision of a specific dose and the desired degree of dose homogeneity are two of the physicist's major considerations for all radiotherapy techniques, these tasks are even more demanding for large field radiotherapy. Because most large field radiotherapy is done at an extended distance for complex patient geometries, basic dosimetry data measured at the standard distance (isocenter) must be verified or supplemented. This paper discusses some of the special dosimetric problems of large field radiotherapy, with specific examples given of the dosimetry of the TBI program for bone marrow transplant at the authors' hospital

  8. Cataract incidence after total-body irradiation

    International Nuclear Information System (INIS)

    Zierhut, D.; Lohr, F.; Schraube, P.; Huber, P.; Haas, R.; Hunstein, W.; Wannenmacher, M.

    1997-01-01

    Purpose: Aim of this retrospective study was to evaluate cataract incidence in a homogeneous group of patients after total-body irradiation followed by autologous bone marrow transplantation or peripheral blood stem cell transplantation. Method and Materials: Between 11/1982 and 6/1994 in total 260 patients received in our hospital total-body irradiation for treatment of haematological malignancy. In 1996-96 patients out of these 260 patients were still alive. 85 from these still living patients (52 men, 33 women) answered evaluable on a questionnaire and could be examined ophthalmologically. Median age of these patients was 38,5 years (15 - 59 years) at time of total-body irradiation. Radiotherapy was applied as hyperfractionated total-body irradiation with a median dose of 14,4 Gy in 12 fractions over 4 days. Minimum time between fractions was 4 hours, photons with a energy of 23 MeV were used, and the dose rate was 7 - 18 cGy/min. Results: Median follow-up is now 5,8 years (1,7 - 13 years). Cataract occurred in (28(85)) patients after a median time of 47 months (1 - 104 months). In 6 out of these 28 patients who developed a cataract, surgery of the cataract was performed. Whole-brain irradiation prior to total-body irradiation was more often in the group of patients developing a cataract (14,3%) vs. 10,7% in the group of patients without cataract. Conclusion: Cataract is a common side effect of total-body irradiation. Cataract incidence found in our patients is comparable to results of other centres using a fractionated regimen for total-body irradiation. The hyperfractionated regimen used in our hospital does obviously not result in a even lower cataract incidence. In contrast to acute and late toxicity in other organ/organsystems, hyperfractionation of total-body irradiation does not further reduce toxicity for the eye-lens. Dose rate may have more influence on cataract incidence

  9. Total body irradiation: current indications; L`irradiation corporelle totale: les indications actuelles

    Energy Technology Data Exchange (ETDEWEB)

    Giraud, P.; Danhier, S.; Dubray, B.; Cosset, J.M. [Institut Curie, 75 - Paris (France)

    1998-05-01

    The choice of dose and fractionation for total body irradiation is made difficult by the large number of considerations to be taken into account. The outcome of bone marrow transplantation after total body irradiation can be understood in terms of tumor cell killing, engraftment, and normal tissue damage, each of these endpoints being influenced by irradiation-, disease-, transplant-, and patient- related factors. Interpretation of clinical data is further hampered by the overwhelming influence of logistic constraints, the small numbers of randomized studies, and the concomitant variations in total dose and fraction size or dose rate. So far, three cautious conclusions can be drawn in order to tentatively adapt the total body irradiation schedule to clinically-relevant situations. Firstly, the organs at risk for normal tissue damage (lung, liver, lens, kidney) are protected by delivering small doses per fraction at low dose rate. This suggests that, when toxicity is at stake (e.g. in children), fractionated irradiation should be preferred, provided that inter-fraction intervals are long enough. Secondly, fractionated irradiation should be avoided in case of T-cell depleted transplant, given the high risk of graft rejection in this setting. An alternative would be to increase total (or fractional) dose of fractionated total body irradiation, but this approach is likely to induce more normal tissue toxicity. Thirdly, clinical data have shown higher relapse rates in chronic myeloid leukemia after fractionated or low dose rate total body irradiation, suggesting that fractionated irradiation should not be recommended, unless total (or fractional) dose is increased. Total body irradiation-containing regimens, primarily cyclophosphamide / total body irradiation, are either equivalent to or better than the chemotherapy-only regimens, primarily busulfan / cyclophosphamide. Busulfan / cyclophosphamide certainly represents a reasonable alternative, especially in patients who

  10. Comparison of three techniques for skin total irradiation with electrons

    International Nuclear Information System (INIS)

    Batista, Delano V.S.; Bardella, Lucia H.; Rosa, Luiz A.R. da

    2011-01-01

    This paper compared three techniques of skin total irradiation with electrons: 1) horizontal positioning, 2) vertical positioning - rotatory technique and 3) vertical positioning - six fields technique. For that, a anthropomorphic phantom was positioned according to the recommendation for each technique and was i radiated at the linear accelerator by using the 6 MeV electrons. Radiochromic films were positioned on the surface in various regions of the phantom for measurement of absorbed dose. A ionization chamber was positioned inside of equivalent issue plates for dose evaluation due to the photons produced by electron stopping. The technique 2 and 3 have shown too similar in the results and number or discrepant points (8 and 10 respectively) of prescription lower than the technique 1 (22 points). The total body dose of photons of the 1, 2 and 3 techniques was 2.2%, 5.3% and 5.2% respectively

  11. Dose characteristics of total-skin electron-beam irradiation with six-dual electron fields

    International Nuclear Information System (INIS)

    Choi, Tae Jin; Kim, Jin Hee; Kim, Ok Bae

    1998-01-01

    To obtain the uniform dose at limited depth to entire surface of the body, the dose characteristics of degraded electron beam of the large target-skin distance and the dose distribution of the six-dual electron fields were investigated. The experimental dose distributions included the depth dose curve, spatial dose and attenuated electron beam were determined with 300 cm of Target-Skin Distance (TSD) and full collimator size (35x35 cm 2 on TSD 100 cm) in 4 MeV electron beam energy. Actual collimated field size of 105 cmx105 cm at the distance of 300 cm could include entire hemibody. A patient was standing on step board with hands up and holding the pole to stabilize his/her positions for the six-dual fields technique. As a scatter-degrader, 0.5 cm of acrylic plate was inserted at 20 cm from the body surface on the electron beam path to induce ray scattering and to increase the skin dose. The Full Width at Half Maximum(FWHM) of dose profile was 130 cm in large field of 105x105 cm 2 . The width of 100±10% of the resultant dose from two adjacent fields which were separated at 25 cm from field edge for obtaining the dose uniformity was extended to 186 cm. The depth of maximum dose lies at 5 mm and the 80% depth dose lies between 7 and 8 mm for the degraded electron beam by using the 0.5 cm thickness of acrylic absorber. Total skin electron beam irradiation (TSEBI) was carried out using the six dual fields has been developed at Stanford University. The dose distribution in TSEBI showed relatively uniform around the flat region of skin except the protruding and deeply curvatured portion of the body, which showed excess of dose at the former and less dose at the latter. The percent depth dose, profile curves and superimposed dose distribution were investigated using the degraded using the degraded electron beam through the beam absorber. The dose distribution obtained by experiments of TSEBI showed within±10% difference excepts the protruding area of skin which needs a

  12. A method for total body irradiation

    International Nuclear Information System (INIS)

    Yasukochi, Hiroshi; Higashi, Shizuka; Okuhata, Yoshitaka; Lee, Keiichi; Ishioka, Kuniaki; Murakami, Koji; Nagai, Jun; Kuniyasu, Yoshio

    1988-01-01

    In these two years, we have treated four infant patients of acute leukemia by Cobalt-60 total body irradiation and bone marrow transplantation. During total body irradiation, thermoluminescence dosimeters were attached to the skin of patients. For four patients, nine dosimetries were performed. Reliability of this method was examined by phantom experiment. Every irradiation for the patient per fraction was 2.4 Gy, that is, 60 cGy for each four positions, right decubitus A-P and PA directions and left decubitus A-P and PA directions under aseptic circumstances. Radiation dose was uniform by this technique for each patient, and average determined dose for surface of the patients was between 87 % and 106 % compared with the air dose of the center of aseptic space (wagon). As the result, we suggest that this method is suitable for the total body irradiation of acute leukemia of infant. (author)

  13. Feasibility study of helical tomotherapy for total body or total marrow irradiation

    International Nuclear Information System (INIS)

    Hui, Susanta K.; Kapatoes, Jeff; Fowler, Jack; Henderson, Douglas; Olivera, Gustavo; Manon, Rafael R.; Gerbi, Bruce; Mackie, T. R.; Welsh, James S.

    2005-01-01

    Total body radiation (TBI) has been used for many years as a preconditioning agent before bone marrow transplantation. Many side effects still plague its use. We investigated the planning and delivery of total body irradiation (TBI) and selective total marrow irradiation (TMI) and a reduced radiation dose to sensitive structures using image-guided helical tomotherapy. To assess the feasibility of using helical tomotherapy (A) we studied variations in pitch, field width, and modulation factor on total body and total marrow helical tomotherapy treatments. We varied these parameters to provide a uniform dose along with a treatment times similar to conventional TBI (15-30 min). (B) We also investigated limited (head, chest, and pelvis) megavoltage CT (MVCT) scanning for the dimensional pretreatment setup verification rather than total body MVCT scanning to shorten the overall treatment time per treatment fraction. (C) We placed thermoluminescent detectors (TLDs) inside a Rando phantom to measure the dose at seven anatomical sites, including the lungs. A simulated TBI treatment showed homogeneous dose coverage (±10%) to the whole body. Doses to the sensitive organs were reduced by 35%-70% of the target dose. TLD measurements on Rando showed an accurate dose delivery (±7%) to the target and critical organs. In the TMI study, the dose was delivered conformally to the bone marrow only. The TBI and TMI treatment delivery time was reduced (by 50%) by increasing the field width from 2.5 to 5.0 cm in the inferior-superior direction. A limited MVCT reduced the target localization time 60% compared to whole body MVCT. MVCT image-guided helical tomotherapy offers a novel method to deliver a precise, homogeneous radiation dose to the whole body target while reducing the dose significantly to all critical organs. A judicious selection of pitch, modulation factor, and field size is required to produce a homogeneous dose distribution along with an acceptable treatment time. In

  14. Radiation nephritis following total-body irradiation and cyclophosphamide in preparation for bone marrow transplantation

    International Nuclear Information System (INIS)

    Bergstein, J.; Andreoli, S.P.; Provisor, A.J.; Yum, M.

    1986-01-01

    Two children prepared for bone marrow transplantation with total-body irradiation and cyclophosphamide developed hypertension, microscopic hematuria, proteinuria, diminished renal function, and anemia six months after transplantation. Light microscopy of the kidneys revealed mesangial expansion, glomerular capillary wall thickening, and lumenal thrombosis. Electron microscopy demonstrated widening of the subendothelial space due to the deposition of amorphous fluffy material. In one patient, immunofluorescence microscopy revealed glomerular capillary wall deposition of fibrin and immunoglobulins. The clinical and histologic findings support the diagnosis of radiation nephritis. Patients prepared for bone marrow transplantation with total-body irradiation and cyclophosphamide should be followed closely after transplantation for the development of hypertension, proteinuria, and renal insufficiency

  15. ACPSEM ROSG TBE working group recommendations for quality assurance in total body electron irradiation

    International Nuclear Information System (INIS)

    Nelligan, Raelene; Baldwin, Zoe; Ostwald, Trish; Tran, Thi; Bailey, Michael

    2015-01-01

    The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups in 2011 to develop recommendations for guidance of radiation oncology medical physics practice within the Australasian setting. These recommendations are intended to provide guidance for safe work practices and a suitable level of quality control without detailed work instructions. It is the responsibility of the medical physicist to ensure that locally available equipment and procedures are sufficiently sensitive to establish compliance to these recommendations. The recommendations are endorsed by the ROSG, and have been subject to independent expert reviews. For the Australian readers, these recommendations should be read in conjunction with the Tripartite Radiation Oncology Reform Implementation Committee Quality Working Group: Radiation Oncology Practice Standards (2011), and Radiation Oncology Practice Standards Supplementary Guide (2011). This publication presents the recommendations of the ACPSEM ROSG Total Body Electron Irradiation Working Group and has been developed in alignment with other international associations. However, these recommendations should be read in conjunction with relevant national, state or territory legislation and local requirements, which take precedence over the ACPSEM recommendations. It is hoped that the users of this and other ACPSEM recommendations will contribute to the development of future versions through the Radiation Oncology Specialty Group of the ACPSEM. This document serves as a guideline for calibration and quality assurance of equipment used for TBE in Australasia.

  16. Therapeutic use of fractionated total body and subtotal body irradiation

    International Nuclear Information System (INIS)

    Loeffler, R.K.

    1981-01-01

    Ninety-one patients were treated using fractionated subtotal body (STBI) or total body irradiation (TBI). These patients had generalized lymphomas, Hodgkin's disease, leukemias, myelomas, seminomas, or oat-cell carcinomas. Subtotal body irradiation is delivered to the entire body, except for the skull and extremities. It was expected that a significantly higher radiation dose could be administered with STBI than with TBI. A five- to ten-fold increase in tolerance for STBI was demonstrated. Many of these patients have had long-term emissions. There is little or no treatment-induced symptomatology, and no sanctuary sites

  17. Estimation of Total Body Fat from Potassium-40 Content

    International Nuclear Information System (INIS)

    Taha Mohamed Taha Ahmed, T.M.T.

    2010-01-01

    This paper concerns on estimation of total body fat from potassium 40 content using total body counting technique. The work performed using fast scan whole body counter. Calibration of that system for K-40 was carried out under assumption that uniformity distribution of radioactivity of potassium was distributed in 10 polyethylene bottles phantom. Different body sizes were represented by 2, 4, 6, 8 and 10 polyethylene bottles; each bottle has a volume of 0.04 m3. The counting efficiency for each body size was determined. Lean body weight (LBW) was calculated for ten males and ten females using appropriate mathematical equation. Total Body Potassium, TBK for the same selected group was measured using whole body counter. A mathematical relationship between lean body weight and potassium content was deduced .Fat contents for some individuals were calculated and weight/height ratio was indicated for fatness.

  18. A new method of body habitus correction for total body potassium measurements

    International Nuclear Information System (INIS)

    O'Hehir, S; Green, S; Beddoe, A H

    2006-01-01

    This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some components of the total measurement uncertainty which are difficult to quantify experimentally. A method is proposed for MCNP-assessed body habitus corrections based on a simple generic anthropomorphic model, scaled for individual height and weight. The use of this model increases patient comfort by reducing the need for comprehensive anthropomorphic measurements. The analysis shows that the total uncertainty in potassium weight determination by this whole body counting methodology for water-filled phantoms with a known amount of potassium is 2.7% (SD). The uncertainty in the method of body habitus correction (applicable also to phantom-based methods) is 1.5% (SD). It is concluded that this new strategy provides a sufficiently accurate model for routine clinical use

  19. A new method of body habitus correction for total body potassium measurements

    Energy Technology Data Exchange (ETDEWEB)

    O' Hehir, S [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom); Green, S [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom); Beddoe, A H [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom)

    2006-09-07

    This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some components of the total measurement uncertainty which are difficult to quantify experimentally. A method is proposed for MCNP-assessed body habitus corrections based on a simple generic anthropomorphic model, scaled for individual height and weight. The use of this model increases patient comfort by reducing the need for comprehensive anthropomorphic measurements. The analysis shows that the total uncertainty in potassium weight determination by this whole body counting methodology for water-filled phantoms with a known amount of potassium is 2.7% (SD). The uncertainty in the method of body habitus correction (applicable also to phantom-based methods) is 1.5% (SD). It is concluded that this new strategy provides a sufficiently accurate model for routine clinical use.

  20. Protective effect of Asparagus racemosus root extract against lethal total - body electron beam radiation induced damage in Swiss albino mice

    International Nuclear Information System (INIS)

    Sharmila, K.P.; Bhandary, B. Satheesh Kumar; Suchetha Kumari, N.; Bhat, Vadish S.; Shetty, Jayaram; Peter, Alex John; Jose, Jerish M.; Fernandes, Ronald

    2016-01-01

    To investigate the protective effect of Asparagus Racemosus Root ethanolic extract (ARE) in Swiss albino mice against acute lethal total - body Electron beam irradiation. Swiss Albino mice were used for the assessment of radiation induced sickness and 30 day survival analysis. Survival studies were determined using the Kaplan-Meier survival curves. The maximum survival was observed in the experimental mice pretreated with 200 mg/kg.b.wt. of ARE which also reduced the radiation sickness characteristics. This dose was considered as an optimal dose for radioprotection. Treatment of mice with ARE before irradiation delayed the onset of mortality as compared with the untreated irradiated controls. Present findings demonstrate the potential of ARE in mitigating radiation-induced mortality, which may be attributed to its free radical scavenging and increased antioxidant potential

  1. Comparison of three techniques for skin total irradiation with electrons; Comparacao de tres tecnicas de irradiacao total da pele com eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Batista, Delano V.S., E-mail: dbatista@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Instituto Nacional de Cancer (INCa), Rio de Janeiro, RJ (Brazil); Bardella, Lucia H. [Instituto Nacional de Cancer (INCa), Rio de Janeiro, RJ (Brazil); Rosa, Luiz A.R. da, E-mail: lrosa@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-10-26

    This paper compared three techniques of skin total irradiation with electrons: 1) horizontal positioning, 2) vertical positioning - rotatory technique and 3) vertical positioning - six fields technique. For that, a anthropomorphic phantom was positioned according to the recommendation for each technique and was i radiated at the linear accelerator by using the 6 MeV electrons. Radiochromic films were positioned on the surface in various regions of the phantom for measurement of absorbed dose. A ionization chamber was positioned inside of equivalent issue plates for dose evaluation due to the photons produced by electron stopping. The technique 2 and 3 have shown too similar in the results and number or discrepant points (8 and 10 respectively) of prescription lower than the technique 1 (22 points). The total body dose of photons of the 1, 2 and 3 techniques was 2.2%, 5.3% and 5.2% respectively

  2. In-vivo determination of total body water and lean body mass in subjects by deuterium dilution

    International Nuclear Information System (INIS)

    Blagojevic, N.; Allen, B.J.; Baur, L.; Gaskin, K.

    1988-01-01

    Total body water (TBW) estimation is one of a number of basic techniques required for the determination of body composition in normal and malnourished subjects. When combined with total body nitrogen (TBN) analysis by prompt gamma neutron activation, an accurate compartmental model of in vivo body composition can be formed, providing valuable nutritional and other data. This study examines the role of TBW on its own in evaluating lean body mass. Total body water was studied in six male and five female subjects using deuterium oxide and a Fourier transform infrared spectrometer. The lean body mass calculated from the results was compared with the lean body mass deduced from established total body nitrogen measurements. A four-compartment model was also used to calculate lean body mass. Excellent agreement was shown between lean body mass derived from TBW, the four-compartment model and TBN. Hence, TBW can provide a fast, cost-efficient method for evaluating normal subjects. However, for disease-induced malnutrition, or highly developed athletes, both TBN and TBW measurements are essential to establish an accurate picture of their body composition. TBW measurements alone can monitor the hydration state of patients and as such have a useful diagnostic value

  3. In-vivo determination of total body water and lean body mass in subjects by deuterium dilution

    Energy Technology Data Exchange (ETDEWEB)

    Blagojevic, N; Allen, B J; Baur, L; Gaskin, K

    1988-12-01

    Total body water (TBW) estimation is one of a number of basic techniques required for the determination of body composition in normal and malnourished subjects. When combined with total body nitrogen (TBN) analysis by prompt gamma neutron activation, an accurate compartmental model of in vivo body composition can be formed, providing valuable nutritional and other data. This study examines the role of TBW on its own in evaluating lean body mass. Total body water was studied in six male and five female subjects using deuterium oxide and a Fourier transform infrared spectrometer. The lean body mass calculated from the results was compared with the lean body mass deduced from established total body nitrogen measurements. A four-compartment model was also used to calculate lean body mass. Excellent agreement was shown between lean body mass derived from TBW, the four-compartment model and TBN. Hence, TBW can provide a fast, cost-efficient method for evaluating normal subjects. However, for disease-induced malnutrition, or highly developed athletes, both TBN and TBW measurements are essential to establish an accurate picture of their body composition. TBW measurements alone can monitor the hydration state of patients and as such have a useful diagnostic value.

  4. First application of hemi-body electron beam irradiation for Kaposi sarcoma at the lower extremities.

    Science.gov (United States)

    Platoni, Kalliopi; Diamantopoulos, Stefanos; Dilvoi, Maria; Delinikolas, Panagiotis; Kypraiou, Efrosyni; Efstathopoulos, Efstathios; Kouloulias, Vassilis

    2018-01-01

    Kaposi's sarcoma (KS) is a systemic neoplastic disease that can present cutaneous symptoms and is usually treated with a systematic approach due to its extent. Due to its radiosensitivity, radiotherapy is considered one of its main treatments, for palliation and local control of the skin and mucosal lesions. The aim of this paper was to report the first case of KS treated by hemi-body electron irradiation protocol in Greece. A fractionated 40 Gy hemi-body electron irradiation was prescribed to a 60-year-old male patient with KS at his legs. Dose uniformity was verified on a daily basis by thermoluminescence dosimetry (TLD). The treatment resulted to complete clinical response. Limited irradiation-derived side effects appeared. This is the first case ever to be treated with hemi-body electron irradiation protocol in Greece. To the best of our knowledge, this is also the first time that a single field hemi-body electron beam irradiation at a total skin electron beam (TSEB)-like configuration is reported to be used for KS.

  5. Acute tolerance of hyperfractionated accelerated total body irradiation

    International Nuclear Information System (INIS)

    Latz, D.; Schraube, P.; Wannenmacher, M.

    1996-01-01

    Background: Acute side effects of total body irradiation lead to intense molestations of the patients. Therefore, it is desirable to take measures to reduce these side effects. In a retrospective study the frequency on acute side effects of a hyperfractionated accelerated total body irradiation was assessed and compared to frequencies of other exposure schedules published in the literature. Additionally the influence of ondansetron on the frequency of nausea and vormiting was investigated. Patients and Method: From 1989 to 1992, 76 patients (47 male, 29 female; median age 38 years) underwent total body irradiation before autologeous bone marrow transplantation. They received 3 daily doses of 1.20 Gy each every 4 h on 4 successive days to a total dose of 14,40 Gy. Thirty-nine patients received 3x8 mg (daily, intravenous or per os) ondansetron during the whole course of irradiation. Results: The most relevant side effects were nausea and vomiting. Patients, who did not receive ondansetron (n=37) showed a nausea and emesis rate of 73%. With ondansetron (n=39) nausea and emesis were reduced to 38%. Also the grade of severity of these side effects was reduced. Conclusions: Ondansetron proved to be an effective medicament for relieving nausea and vormiting during total body irradiation. The results obtained are in concordance with those published in the literature. (orig.) [de

  6. Total body and regional bone mineral content in hemodialysis patients

    International Nuclear Information System (INIS)

    Hagiwara, Satoshi; Aratani, Hideyui; Miki, Takami; Nishizawa, Yoshiki; Okamura, Terue; Koizumi, Yoshiko; Ochi, Hironobu; Morii, Hirotoshi

    1994-01-01

    Bone mineral content (BMC) in the total body and lumbar spine was evaluated in 126 hemodialysis patients (60 males, 66 females) by dual photon absorptiometry with the Norland DBD 2600. Measurements of: 1) total body BMC divided by lean body mass (BMC TB /LBM), 2) bone mineral density (BMD) of total body, 3) BMD of four regional sections (head, trunk, pelvis, and legs), and 4) BMD of lumbar spine, generally showed a significant decrease in the hemodialysis patients compared to the reference population. However, arm BMD did not show a significant difference between patients and control populations. The z-score of BMC TB /LBM declined significantly throughout the duration of hemodialysis, although that of the lumbar spine BMD did not. It should be noted that the degree of decrease in BMC was more prominent in the total body measurement than in the lumbar spine measurement. There was preferential osteopenia of the total body in the hemodialysis patients. Although the lumbar spine BMD showed a lower value than the control population, the lumbar spine is not the recommended region to monitor the BMD change in hemodialysis patients. (author)

  7. Changes in body chemical composition with age measured by total-body neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Vaswani, A.; Zanzi, I.; Aloia, J.F.; Roginsky, M.S.; Ellis, K.J.

    1976-01-01

    Total-body levels of calcium and phosphorus (reflecting skeletal mass) and total-body levels of potassium (reflecting muscle mass) were measured by neutron activation analysis in 39 men and 40 women ages 30 to 90 yr. In order to intercompare the total body calcium (TBCa) values in a heterogeneous population, such as this, it was necessary to normalize the data for skeletal size. The normalization consisted of dividing the absolute calcium level by the predicted calcium level for each individual matched to a set of critical parameters. The parameter used in the computation of normal values were age, sex, muscle mass, i.e., total body potassium (TBK) and height. For the calcium data of the women, it was necessary to add an age correction factor after the age of 55 yr. The calcium ratio (mean ratio of the predicted to measured TBCa) in men was 1.000 +- 7.8 percent and in women 0.996 +- 7.1 percent. The TBCa of normal males and females can thus be predicted to +-13 percent (at the 90 percent confidence level). An exception to this was found in males (70 to 90 yr) who exhibited a mean calcium ratio greater than 1.13

  8. Quality control of dosimetry in total body irradiation

    International Nuclear Information System (INIS)

    Kallinger, W.

    1986-11-01

    An on-line dose measurement system for the quality control of the treatment of leukemia by means of total body irradiation with Co-60 gamma radiation is introduced. An ionization chamber and 5 diodes arranged on the surface of the patient incorporated with a microprocessor provides useful information and data necessary for the treatment. Following the concerted treatment procedure employing this system, the treatment of leukemia by means of total body irradiation is expected to be improved

  9. Electron capture in proton collisions with alkali atoms as a three-body problem

    International Nuclear Information System (INIS)

    Avakov, G.V.; Blokhintsev, L.D.; Kadyrov, A.S.; Mukhamedzhanov, A.M.

    1992-01-01

    A previous paper proposed an approach to the calculation of electron transfer reactions in ion-atomic collisions based on the Faddeev three-body equations written in the Alt-Grassberger-Sandhas form. In the present work this approach is used to describe the electron capture in proton collisions with alkali atoms. The results of calculation of the total and partial cross sections for charge exchange in proton collisions with Li, Na, K and Rb atoms are presented. The calculated total cross sections are in good agreement with experiment for light target atoms. In going over to heavier targets, the theoretical total cross sections, while agreeing in form, tend to be larger than the experimental ones. The calculated partial cross sections for electron capture into the 2s state of the H atom are also in agreement with experiment. Some other partial cross sections were also calculated. (author)

  10. Myeloproliferative disorders in patients with rheumatoid arthritis treated with total body irradiation

    International Nuclear Information System (INIS)

    Urowitz, M.B.; Rider, W.D.

    1985-01-01

    Four patients with refractory rheumatoid arthritis were treated with total body irradiation administered in two sittings, 300 to 400 rads to each half of the body. All four patients had taken antimetabolites prior to receiving total body irradiation, and two continued to use them after total body irradiation. Two patients had taken alkylating agents before, and one had used them after total body irradiation. All patients showed clinical improvement. However, in two patients myeloproliferative disorders developed: a myelodysplastic preleukemia at 40 months after total body irradiation in one and acute myelogenous leukemia at 25 months in the other. Total body irradiation differs from total nodal irradiation in the total dose of irradiation (300 to 400 rads versus 2,000 to 3,000), and in the duration of the therapy (two sittings versus treatment over several weeks to months). Furthermore, the patients in the total body irradiation study frequently used cytotoxic drugs before and/or after irradiation, whereas in one total nodal irradiation study, azathioprine (2 mg/kg per day or less) was permitted, but no other cytotoxic agents were allowed. Rheumatologists may therefore face a binding decision when deciding to treat a patient with rheumatoid arthritis with either a cytotoxic drug or irradiation

  11. Total body irradiation with a reconditioned cobalt teletherapy unit.

    Science.gov (United States)

    Evans, Michael D C; Larouche, Renée-Xavière; Olivares, Marina; Léger, Pierre; Larkin, Joe; Freeman, Carolyn R; Podgorsak, Ervin B

    2006-01-01

    While the current trend in radiotherapy is to replace cobalt teletherapy units with more versatile and technologically advanced linear accelerators, there remain some useful applications for older cobalt units. The expansion of our radiotherapy department involved the decommissioning of an isocentric cobalt teletherapy unit and the replacement of a column-mounted 4-MV LINAC that has been used for total body irradiation (TBI). To continue offering TBI treatments, we converted the decommissioned cobalt unit into a dedicated fixed-field total body irradiator and installed it in an existing medium-energy LINAC bunker. This article describes the logistical and dosimetric aspects of bringing a reconditioned cobalt teletherapy unit into clinical service as a total body irradiator.

  12. Implantation of total body irradiation in radiotherapy

    International Nuclear Information System (INIS)

    Habitzreuter, Angela Beatriz

    2010-01-01

    Before implementing a treatment technique, the characteristics of the beam under irradiation conditions must be well acknowledged and studied. Each one of the parameters used to calculate the dose has to be measured and validated before its utilization in clinical practice. This is particularly necessary when dealing with special techniques. In this work, all necessary parameters and measurements are described for the total body irradiation implementation in facilities designed for conventional treatments that make use of unconventional geometries to generate desired enlarged field sizes. Furthermore, this work presents commissioning data of this modality at Hospital das Clinicas of Sao Paulo using comparison of three detectors types for measurements of entrance dose during total body irradiation treatment. (author)

  13. Total skin electron irradiation: evaluation of dose uniformity throughout the skin surface

    International Nuclear Information System (INIS)

    Anacak, Yavuz; Arican, Zumre; Bar-Deroma, Raquel; Tamir, Ada; Kuten, Abraham

    2003-01-01

    In this study, in vivo dosimetic data of 67 total skin electron irradiation (TSEI) treatments were analyzed. Thermoluminescent dosimetry (TLD) measurements were made at 10 different body points for every patient. The results demonstrated that the dose inhomogeneity throughout the skin surface is around 15%. The homogeneity was better at the trunk than at the extratrunk points, and was worse when a degrader was used. There was minimal improvement of homogeneity in subsequent days of treatment

  14. Clinical implementation of total skin electron irradiation treatment with a 6 MeV electron beam in high-dose total skin electron mode

    International Nuclear Information System (INIS)

    Lucero, J. F.; Rojas, J. I.

    2016-01-01

    Total skin electron irradiation (TSEI) is a special treatment technique offered by modern radiation oncology facilities, given for the treatment of mycosis fungoides, a rare skin disease, which is type of cutaneous T-cell lymphoma [1]. During treatment the patient’s entire skin is irradiated with a uniform dose. The aim of this work is to present implementation of total skin electron irradiation treatment using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films.

  15. Clinical implementation of total skin electron irradiation treatment with a 6 MeV electron beam in high-dose total skin electron mode

    Energy Technology Data Exchange (ETDEWEB)

    Lucero, J. F., E-mail: fernando.lucero@hoperadiotherapy.com.gt [Universidad Nacional de Costa Rica, Heredia (Costa Rica); Hope International, Guatemala (Guatemala); Rojas, J. I., E-mail: isaac.rojas@siglo21.cr [Centro Médico Radioterapia Siglo XXI, San José (Costa Rica)

    2016-07-07

    Total skin electron irradiation (TSEI) is a special treatment technique offered by modern radiation oncology facilities, given for the treatment of mycosis fungoides, a rare skin disease, which is type of cutaneous T-cell lymphoma [1]. During treatment the patient’s entire skin is irradiated with a uniform dose. The aim of this work is to present implementation of total skin electron irradiation treatment using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films.

  16. Normal levels of total body sodium and chlorine by neutron activation analysis

    International Nuclear Information System (INIS)

    Kennedy, N.S.J.; Eastell, R.; Smith, M.A.; Tothill, P.

    1983-01-01

    In vivo neutron activation analysis was used to measure total body sodium and chlorine in 18 male and 18 female normal adults. Corrections for body size were developed. Normalisation factors were derived which enable the prediction of the normal levels of sodium and chlorine in a subject. The coefficient of variation of normalised sodium was 5.9% in men and 6.9% in women, and of normalised chlorine 9.3% in men and 5.5% in women. In the range examined (40-70 years) no significant age dependence was observed for either element. Total body sodium was correlated with total body chlorine and total body calcium. Sodium excess, defined as the amount of body sodium in excess of that associated with chlorine, also correlated well with total body calcium. In females there was a mean annual loss of sodium excess of 1.2% after the menopause, similar to the loss of calcium. (author)

  17. Evaluation of body composition and nitrogen content of renal patients on chronic dialysis as determined by total body neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Brennan, B.L.; Yasumura, S.; Vartsky, D.; Vaswani, A.N.; Ellis, K.J.

    1983-01-01

    Total body protein (nitrogen), body cell mass (potassium), fat, and water were measured in 15 renal patients on maintenance hemodialysis (MHD). Total body nitrogen was measured by means of prompt γ neutron activation analysis; total body water was determined with tritium labeled water; total body potassium was measured by whole body counting. The extracellular water was determined by a technique utilizing the measurement of total body chloride and plasma chloride. When compared with corresponding values of a control group of the same age, sex, and height, the protein content, body cell mass, and total body fat of the MHD patients were within the normal range. The only significant change was an increase in the extracellular water/body cell mass ratio in the male MHD patients compared to the control. The lack of significant difference of the nitrogen values of the MHD patients compared to matched controls suggests that dialysis minimizes any residual effects of uremic toxicity or protein-calorie malnutrition. These findings further suggest that there is a need to reevaluate the traditional anthropometric and biochemical standards of nutritional status for MHD patients. It was concluded that it is particularly important to measure protein stores of MHD patients with low protein intake to ascertain nutritional status. Finally, in vivo measurement of total body nitrogen and potassium for determination of body composition provides a simple, direct, and accurate assessment of the nutritional status of MHD patients

  18. A simple calibration of a whole-body counter for the measurement of total body potassium in humans

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; El-Fiki, S.A.; El-Enany, N.; Youssef, S.K.; Aly, A.M.; Abbas, M.T.

    1992-01-01

    A simple calibration procedure for the Inshas whole body counter for evaluating total body potassium has been adopted. More than 120 Egyptian employees in the Nuclear Research Center (N.R.C.) were studied for their total body potassium (TBK). The potassium values were found to have an average of 2.85±0.57 g K kg -1 body weight for males and 2.62±0.52 g K kg -1 for females, which are higher than the recommended value given for reference man by ICRP. The TBK varied directly with body build index and is slightly sex dependent (Author)

  19. Integral bounds for N-body total cross sections

    International Nuclear Information System (INIS)

    Osborn, T.A.; Bolle, D.

    1979-01-01

    We study the behavior of the total cross sections in the three- and N-body scattering problem. Working within the framework of the time-dependent two-Hilbert space scattering theory, we give a simple derivation of integral bounds for the total cross section for all processes initiated by the collision of two clusters. By combining the optical theorem with a trace identity derived by Jauch, Sinha, and Misra, we find, roughly speaking, that if the local pairwise interaction falls off faster than r -3 , then sigma/sub tot/(E) must decrease faster than E/sup -1/2/ at high energy. This conclusion is unchanged if one introduces a class of well-behaved three-body interactions

  20. Galectin-3 levels relate in children to total body fat, abdominal fat, body fat distribution, and cardiac size.

    Science.gov (United States)

    Dencker, Magnus; Arvidsson, Daniel; Karlsson, Magnus K; Wollmer, Per; Andersen, Lars B; Thorsson, Ola

    2018-03-01

    Galectin-3 has recently been proposed as a novel biomarker for cardiovascular disease in adults. The purpose of this investigation was to assess relationships between galectin-3 levels and total body fat, abdominal fat, body fat distribution, aerobic fitness, blood pressure, left ventricular mass, left atrial size, and increase in body fat over a 2-year period in a population-based sample of children. Our study included 170 children aged 8-11 years. Total fat mass and abdominal fat were measured by dual-energy x-ray absorptiometry (DXA). Body fat distribution was expressed as abdominal fat/total fat mass. Maximal oxygen uptake was assessed by indirect calorimetry during a maximal exercise test and scaled to body mass. Systolic and diastolic blood pressure and pulse pressure were measured. Left atrial size, left ventricular mass, and relative wall thickness were measured by echocardiography. Frozen serum samples were analyzed for galectin-3 by the Proximity Extension Assay technique. A follow-up DXA scan was performed in 152 children 2 years after the baseline exam. Partial correlations, with adjustment for sex and age, between galectin-3 versus body fat measurements indicated weak to moderate relationships. Moreover, left atrial size, left ventricular mass, and relative wall thickness and pulse pressure were also correlated with galectin-3. Neither systolic blood pressure nor maximal oxygen uptake was correlated with galectin-3. There was also a correlation between galectin-3 and increase in total body fat over 2 years, while no such correlations were found for the other fat measurements. More body fat and abdominal fat, more abdominal body fat distribution, more left ventricular mass, and increased left atrial size were all associated with higher levels of galectin-3. Increase in total body fat over 2 years was also associated with higher levels of galectin-3. What is Known: • Galectin-3 has been linked to obesity and been proposed to be a novel biomarker

  1. Total cross sections for electron scattering by He

    International Nuclear Information System (INIS)

    De Heer, F.J.; Jansen, R.H.J.

    1977-01-01

    A set of total cross sections for scattering of electrons by He has been evaluated over the energy range of zero to 3000 eV by means of the analysis of experiments and theories on total cross sections for elastic scattering, ionisation and excitation, and on differential cross sections for elastic and inelastic scattering. Between 0 and 19.8 eV, where no inelastic processes occur, the total cross sections for scattering are equal to those for elastic scattering. Above 19.8 eV total cross sections for scattering of electrons have been evaluated by adding those for ionisation, excitation and elastic scattering. The total cross sections thus obtained are probably accurate to about 5% over a large part of the energy range. They appear to be in very good agreement with the recent experimental results of Blaauw et al. (J. Phys. B.; 10:L299 (1977)). The present results have already proved useful for application in the dispersion relation for forward scattering in electron-helium collisions. (author)

  2. Total body fat as a possible indicator of metabolic syndrome in adults

    Directory of Open Access Journals (Sweden)

    Edgar Navarro Lechuga

    2016-09-01

    Full Text Available Introduction: The metabolic syndrome is a set of factors related to insulin resistance, which increases the likelihood of coronary events. It is important timely onset identifying to reduce its prevalence. Objective: To explore the percentage of total body fat as indicator of metabolic syndrome in adults from Soledad, Colombia. Material and Methods: Cross-sectional study. n=99 adults (non-pregnant, nor subjects with psychomotor disturbances. Blood samples were taken: total cholesterol, HDL; triglycerides and glucose. Waist circumference, Body Mass Index and body fat by bioimpedance and skinfold thickness were measured. Diagnosis of metabolic syndrome was made according to NHLBI/AHA, ATP III and IDF criteria. Subjects with and without metabolic syndrome according to total body fat averages were compared. Results: The average percentage of body fat was higher (p0.05 in the classification according to ATP III in women, where the average fat percentage was 39.31 % in those with metabolic syndrome and 37.7% in those not suffering. Conclusions: Subjects with metabolic syndrome have higher mean total body fat, significantly, compared with those who did not, so it could be considered the values of total body fat obtained by bioimpedance as future indicators of metabolic syndrome, both as screening and control.

  3. SU-F-T-82: Dosimetric Evaluation of a Shield Used for Hemi-Body Skin Electron Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Rivers, C; Singh, A [Roswell Park Cancer Institute, Buffalo, NY (United States); AlDahlawi, I; Wang, I; Podgorsak, M [Roswell Park Cancer Institute, Buffalo, NY (United States); State University of New York at Buffalo, Buffalo, NY (United States)

    2016-06-15

    Purpose: We had several mycosis fungoides patients with a limited disease to about half of the skin surface. A custom-made plywood shield was used to protect the non-targeted skin region with our total skin electron irradiation (TSEI) technique. We report a dosimetric evaluation for our “hemi-body” skin electron irradiation technique. Methods: The technique is similar to our clinical total skin electron irradiation (TSEI), performed with a six-pair dual field (Stanford technique) at an extended source-to-skin distance (SSD) of 377 cm, with the addition of a plywood shield placed 50 cm from the patient. The shield is made of three layers of standard 5/8″ thick plywood (total thickness of 4.75 cm) that are clamped securely on an adjustable-height stand. Gafchromic EBT3 films were used in assessing the shield’s transmission factor and the extend of the dose penumbra region. To verify the dose delivered for hemi-body skin radiation in a real patient treatment, in-vivo dosimetry using Gafchromic EBT3 films were performed. Film pieces were taped on the patient skin to measure the dose received during the first two fractions, placed on the forehead and upper body (shielded region); and also at the level of pelvic area, left thigh, and left ankle. Results: The shield transmission factor was found to be 10%, and the width of the penumbra (80-to-20% dose fall-off) was about 12 cm. In-vivo dosimetry of a real case confirmed the expected shielded area dose. Conclusion: Hemi-Body skin electron irradiation at an extended SSD is feasible with the addition of a plywood shield at a distance from patient skin. The penumbra dose region and the shield’s transmission factor should be evaluated prior to clinical use. We have treated several hemi-body skin patients with our custom-made plywood shield, the current patient measurements are representative of these for other patients as well.

  4. Total Body Opacification 'Technique Neonatal Adrenal Haemorrhage

    African Journals Online (AJOL)

    1971-12-11

    Dec 11, 1971 ... A case is reported illustrating the possible usefulness of total body opacification in the diagnosis of neonatal adrenal haemorrhage. To derive maximum benefit from this principle, the routine use of an early film coupled with high dosage is urged whenever an intravenous pyelogram is performed for ...

  5. US-Total Electron Content Product (USTEC)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The US Total Electron Content (US-TEC) product is designed to specify TEC over the Continental US (CONUS) in near real-time. The product uses a Kalman Filter data...

  6. Serum protein concentration in low-dose total body irradiation of normal and malnourished rats

    International Nuclear Information System (INIS)

    Viana, W.C.M.; Lambertz, D.; Borges, E.S.; Neto, A.M.O.; Lambertz, K.M.F.T.; Amaral, A.

    2016-01-01

    Among the radiotherapeutics' modalities, total body irradiation (TBI) is used as treatment for certain hematological, oncological and immunological diseases. The aim of this study was to evaluate the long-term effects of low-dose TBI on plasma concentration of total protein and albumin using prematurely and undernourished rats as animal model. For this, four groups with 9 animals each were formed: Normal nourished (N); Malnourished (M); Irradiated Normal nourished (IN); Irradiated Malnourished (IM). At the age of 28 days, rats of the IN and IM groups underwent total body gamma irradiation with a source of cobalt-60. Total protein and Albumin in the blood serum was quantified by colorimetry. This research indicates that procedures involving low-dose total body irradiation in children have repercussions in the reduction in body-mass as well as in the plasma levels of total protein and albumin. Our findings reinforce the periodic monitoring of total serum protein and albumin levels as an important tool in long-term follow-up of pediatric patients in treatments associated to total body irradiation. - Highlights: • Low-dose total body irradiation (TBI) in children have repercussions in their body-mass. • Long-term total protein and albumin levels are affected by TBI. • The monitoring of total protein and albumin levels are useful in the follow-up of TBI pediatric patients.

  7. Total body irradiation as a form of preparation for bone marrow transplantation

    International Nuclear Information System (INIS)

    Inoue, Toshihiko

    1987-01-01

    The history of total body irradiation and bone marrow transplantation is surprisingly old. Following the success of Thomas et al. in the 1970s, bone marrow transplantation appeared to be the sole curative treatment modality for high-risk leukemia. A supralethal dose of total body irradiation was widely accepted as a form of preparation for bone marrow transplantation. In this paper, I described the present status of bone marrow transplantation for leukemia patients in Japan based on the IVth national survey. Since interstitial pneumonitis was one of the most life threatening complications after bone marrow transplantation, I mentioned the dose, dose-rate and fraction of total body irradiation in more detail. In addition, I dealt with some problems of the total body irradiation, such as dose prescription, compensating contour as well as inhomogeneity, and shielding for the highrisk organs. (author) 82 refs

  8. Atlas of total body radionuclide imaging. Volume I and II

    International Nuclear Information System (INIS)

    Fordham, E.W.; Ali, A.; Turner, D.A.; Charters, J.

    1982-01-01

    This two-volume work on total body imaging may well be regarded by future historians of nuclear medicine as representing the high points in the art of total body imaging in clinical nuclear medicine. With regard to information content and volume, it is the largest collection of well-interpreted, beautifully reproduced, total body images available to date. The primary goal of this atlas is to demonstrate patterns of abnormality in both typical and less typical variations. This goal is accomplished with many well-described examples of technical artifacts, of normal variants, of common and of rare diseases, and of pitfalls in interpretations. Volume I is entirely dedicated to skeletal imaging with Tc-99m labeled phosphates or phosphonates. The volume is divided into 22 chapters, which include chapters on methodology and instrumentation, chapters on the important bone diseases and other topics such as a treatise on false-negative and false-positive scans, and soft tissue and urinary tract abnormalities recognizable on bone scintigrams

  9. Marrow toxicity of fractionated vs. single dose total body irradiation is identical in a canine model

    International Nuclear Information System (INIS)

    Storb, R.; Raff, R.F.; Graham, T.; Appelbaum, F.R.; Deeg, H.J.; Schuening, F.G.; Shulman, H.; Pepe, M.

    1993-01-01

    The authors explored in dogs the marrow toxicity of single dose total body irradiation delivered from two opposing 60 Co sources at a rate of 10 cGy/min and compared results to those seen with total body irradiation administered in 100 cGy fractions with minimum interfraction intervals of 6 hr. Dogs were not given marrow transplants. They found that 200 cGy single dose total body irradiation was sublethal, with 12 of 13 dogs showing hematopoietic recovery and survival. Seven of 21 dogs given 300 cGy single dose total body irradiation survived compared to 6 of 10 dogs given 300 cGy fractionated total body irradiation. One of 28 dogs given 400 cGy single dose total body irradiation survived compared to none of six given fractionated radiation. With granulocyte colony stimulating factor (GCSF) administered from day 0-21 after 400 cGy total body irradiation, most dogs survived with hematological recovery. Because of the almost uniform success with GCSF after 400 cGy single dose total body irradiation, a study of GCSF after 400 cGy fractionated total body irradiation was deemed not to be informative and, thus, not carried out. Additional comparisons between single dose and fractionated total body irradiation were carried out with GCSF administered after 500 and 600 cGy of total body irradiation. As with lower doses of total body irradiation, no significant survival differences were seen between the two modes of total body irradiation, and only 3 of 26 dogs studied survived with complete hematological recovery. Overall, therefore, survival among dogs given single dose total body irradiation was not different from that of dogs given fractionated total body irradiation (p = .67). Similarly, the slopes of the postirradiation declines of granulocyte and platelet counts and the rates of their recovery in surviving dogs given equal total doses of single versus fractionated total body irradiation were indistinguishable. 24 refs., 3 figs., 2 tabs

  10. Gigapixel photography for skin cancer surveillance: a novel alternative to total-body photography.

    Science.gov (United States)

    Mikailov, Anar; Blechman, Adam

    2013-11-01

    There is substantial evidence supporting the use of cutaneous imaging in combination with standard total-body skin examinations for early detection and treatment of melanoma. In the last 2 decades, total-body photography (TBP) has been widely used in combination with standard total-body skin examinations for active skin cancer surveillance with proven clinical utility; however, the groundbreaking image detail provided by gigapixel photography (GP) could improve dermatologists' ability to monitor suspicious lesions and therefore could serve a critical role in supplementing traditional total-body skin examinations for skin cancer surveillance. Although it has been successfully implemented in other fields, future studies are required to determine the effectiveness of GP in dermatology.

  11. Dosimetric analysis for photon and electron beams in Whole body irradiation; Analisis dosimetrico para haces de fotones y electrones en irradiacion corporal total

    Energy Technology Data Exchange (ETDEWEB)

    Hurtado G, M [Posgrado. Fisica Medica Radiologica. Universidad Nacional de Colombia, Bogota. Instituto Nacional de Cancerologia. Instituto Regional de Cancer de la Orinoquia. Hospital Regional de Villavicencio, Meta (Colombia)

    1999-12-31

    To initiate the Whole body irradiation as an alternative for the treatment of the hematological diseases, leukemia and assistant for the osseous marrow transplantation, it may be taken account the application of International Protocols about control and quality assurance. It is established the intercomparison by the different dosimetric methods: cylindrical ionization chambers and parallel plane, radiographic emulsion film, semiconductor diodes (Mosfet transistors) and TLD-100 thermoluminescent crystals, obtained measurements for 140 x 140 cm{sup 2} fields and large distances 340 cm respect conventional fields in Radiotherapy. The in vitro dosimetry was realized at the Universal Anthropomorphic puppet Alderson Rando basically with the cylindrical crystals (1 mm diameter) of TLD-100 lithium fluoride. It was obtained the dose value with a 0.6 cm{sup 3} cylindrical ionization chamber and the Farmer electrometer for Whole body irradiation (ICT) with photons for electrons and were obtained values with the Markus plane parallel camera. Knowing the dose rate value to the source-surface distance DFS= 80 cm, it was calibrated the crystals with the reference radiation beam of {sup 60} Co for obtaining the response curve: Dose vs. Tl lecture. It was characterized the 10 % of the total population for 300 crystals for applying the statistics corresponding. The luminescence curve obtained of Gaussian form was considered satisfactory by its stability during the pre-anneal lecture and anneal process, getting the main peak lecture at 300 Centigrade according to assigned parameters at lecture equipment TLD Harshaw model 4500. The results indicate the functional dependence with the distance DFS= 340 cm for the following depth PPD, the relations TMR and TPR, the TAR is not calculated by the increment of the dispersion in air. The penumbra increment indicates an increase of the radiation field respect of luminous field. The dispersion angle q{sub 1} respect at the field central axis

  12. Dosimetric analysis for photon and electron beams in Whole body irradiation; Analisis dosimetrico para haces de fotones y electrones en irradiacion corporal total

    Energy Technology Data Exchange (ETDEWEB)

    Hurtado G, M. [Posgrado. Fisica Medica Radiologica. Universidad Nacional de Colombia, Bogota. Instituto Nacional de Cancerologia. Instituto Regional de Cancer de la Orinoquia. Hospital Regional de Villavicencio, Meta (Colombia)

    1998-12-31

    To initiate the Whole body irradiation as an alternative for the treatment of the hematological diseases, leukemia and assistant for the osseous marrow transplantation, it may be taken account the application of International Protocols about control and quality assurance. It is established the intercomparison by the different dosimetric methods: cylindrical ionization chambers and parallel plane, radiographic emulsion film, semiconductor diodes (Mosfet transistors) and TLD-100 thermoluminescent crystals, obtained measurements for 140 x 140 cm{sup 2} fields and large distances 340 cm respect conventional fields in Radiotherapy. The in vitro dosimetry was realized at the Universal Anthropomorphic puppet Alderson Rando basically with the cylindrical crystals (1 mm diameter) of TLD-100 lithium fluoride. It was obtained the dose value with a 0.6 cm{sup 3} cylindrical ionization chamber and the Farmer electrometer for Whole body irradiation (ICT) with photons for electrons and were obtained values with the Markus plane parallel camera. Knowing the dose rate value to the source-surface distance DFS= 80 cm, it was calibrated the crystals with the reference radiation beam of {sup 60} Co for obtaining the response curve: Dose vs. Tl lecture. It was characterized the 10 % of the total population for 300 crystals for applying the statistics corresponding. The luminescence curve obtained of Gaussian form was considered satisfactory by its stability during the pre-anneal lecture and anneal process, getting the main peak lecture at 300 Centigrade according to assigned parameters at lecture equipment TLD Harshaw model 4500. The results indicate the functional dependence with the distance DFS= 340 cm for the following depth PPD, the relations TMR and TPR, the TAR is not calculated by the increment of the dispersion in air. The penumbra increment indicates an increase of the radiation field respect of luminous field. The dispersion angle q{sub 1} respect at the field central axis

  13. Spin-dependent electron many-body effects in GaAs

    Science.gov (United States)

    Nemec, P.; Kerachian, Y.; van Driel, H. M.; Smirl, Arthur L.

    2005-12-01

    Time- and polarization-resolved differential transmission measurements employing same and oppositely circularly polarized 150fs optical pulses are used to investigate spin characteristics of conduction band electrons in bulk GaAs at 295K . Electrons and holes with densities in the 2×1016cm-3-1018cm-3 range are generated and probed with pulses whose center wavelength is between 865 and 775nm . The transmissivity results can be explained in terms of the spin sensitivity of both phase-space filling and many-body effects (band-gap renormalization and screening of the Coulomb enhancement factor). For excitation and probing at 865nm , just above the band-gap edge, the transmissivity changes mainly reflect spin-dependent phase-space filling which is dominated by the electron Fermi factors. However, for 775nm probing, the influence of many-body effects on the induced transmission change are comparable with those from reduced phase space filling, exposing the spin dependence of the many-body effects. If one does not take account of these spin-dependent effects one can misinterpret both the magnitude and time evolution of the electron spin polarization. For suitable measurements we find that the electron spin relaxation time is 130ps .

  14. Total and regional body-composition changes in early postmenopausal women

    DEFF Research Database (Denmark)

    Wang, Q; Hassager, C; Ravn, Pernille

    1994-01-01

    Total and regional body composition were measured in 373 early postmenopausal women aged 49-60 y by dual-energy x-ray absorptiometry to evaluate whether the changes in body composition in the early postmenopausal years are related to menopause itself or merely to age. Both fat mass and fat...

  15. In vivo measurement of total body carbon using 238Pu/Be neutron sources

    International Nuclear Information System (INIS)

    Sutcliffe, J.F.; Mitra, S.; Hill, G.L.

    1990-01-01

    Total body carbon has been measured by in vivo neutron activation analysis (IVNAA) in 278 surgical gastroenterological patients and 29 normal volunteers. This is based on the inelastic scattering reaction { 12 C(n,n') 12 C*} for neutrons with energy above 4.8MeV, producing 4.43 MeV gamma rays. Since only part of the body is scanned, total body carbon is estimated as the ratio of the gamma ray emission from carbon to the emission from hydrogen, using hydrogen as the internal standard. The precision of the estimate is ±1.6kg for a whole body dose of 0.3mSv. There is a significant difference between the estimates of total body water from IVNAA measurements of carbon and nitrogen and measurements of body water in these subjects by tritium dilution (t=3.1, p < 0.005). (author)

  16. Measurements of the total-body potassium contents. Application of reference value with the whole-body counter

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tetsuo [Chiba Univ. (Japan). Inst. for Training Radiological Technicians; Saegusa, Kenji; Arimizu, Noboru; Kuniyasu, Yoshio; Itoh, Hisao

    2001-08-01

    The total-body potassium contents were measured in 405 healthy volunteers and 186 patients with whole body counter in Chiba University Hospital. The total-body potassium contents was expressed by the reference value (R value). The R value was calculated as measured potassium contents (g) divided by the body surface area (m{sup 2}) and adjusted by age and sex of healthy persons. The R value was 100.65{+-}9.22% in 405 healthy volunteers. Those of each disease were as follows: liver cirrhosis; 94.24{+-}11.22%, chronic hepatitis; 95.74{+-}11.24%, hyperthyroidism; 99.37{+-}10.8%, periodic paralysis; 82.0{+-}9.01%, Barter's syndrome; 93.99{+-}9.86%, myasthenia gravis; 97.34{+-}6.42% and hypo-potassemia; 90.64{+-}11.76%, respectively. The R values of other diseases such as uterine cancer, breast cancer, anemia, hypertension were 97.78{+-}11.5%, 99.22{+-}8.88%, 96.64{+-}12.73%, 98.5{+-}9.63% respectively. Fourteen patients showed especially lower R values under 75%. These were 1 liver cirrhosis, 3 hypertension, 1 diabetes mellitus, 3 hypo-potassemia, 1 periodic paralysis, 2 Barter's syndrome, 2 chemical poisoning, and 1 breast cancer. Follow-up study was performed in some patients with the lower R values. The result of follow-up study showed that there was a relationship between improvement of symptoms and increase of total body potassium contents. (author)

  17. Measurements of the total-body potassium contents. Application of reference value with the whole-body counter

    International Nuclear Information System (INIS)

    Yamamoto, Tetsuo; Saegusa, Kenji; Arimizu, Noboru; Kuniyasu, Yoshio; Itoh, Hisao

    2001-01-01

    The total-body potassium contents were measured in 405 healthy volunteers and 186 patients with whole body counter in Chiba University Hospital. The total-body potassium contents was expressed by the reference value (R value). The R value was calculated as measured potassium contents (g) divided by the body surface area (m 2 ) and adjusted by age and sex of healthy persons. The R value was 100.65±9.22% in 405 healthy volunteers. Those of each disease were as follows: liver cirrhosis; 94.24±11.22%, chronic hepatitis; 95.74±11.24%, hyperthyroidism; 99.37±10.8%, periodic paralysis; 82.0±9.01%, Barter's syndrome; 93.99±9.86%, myasthenia gravis; 97.34±6.42% and hypo-potassemia; 90.64±11.76%, respectively. The R values of other diseases such as uterine cancer, breast cancer, anemia, hypertension were 97.78±11.5%, 99.22±8.88%, 96.64±12.73%, 98.5±9.63% respectively. Fourteen patients showed especially lower R values under 75%. These were 1 liver cirrhosis, 3 hypertension, 1 diabetes mellitus, 3 hypo-potassemia, 1 periodic paralysis, 2 Barter's syndrome, 2 chemical poisoning, and 1 breast cancer. Follow-up study was performed in some patients with the lower R values. The result of follow-up study showed that there was a relationship between improvement of symptoms and increase of total body potassium contents. (author)

  18. Measurement of total body radioactivity in man

    International Nuclear Information System (INIS)

    Naversten, Y.

    1982-01-01

    Techniques for the determination of whole-body radioactivity in man using uncollimated NaI(Tl) detectors have been studied. Geometrical effects and photon attenuation effects due to the different shapes of humans as well as due to varying in-vivo radioactivity distributions have been evaluated particularly for scanning-bed geometries and the chair geometry. Theoretically it is shown that the attenuation effects are generally dominating, for full-energy-peak pulse-range methods. For the application in radiation protection a cheap and simple chair-geometry unit has been constructed and used at various places distantly from the home-laboratory, for studies of body activity of Cs-137 in northern Sweden. High body activities were found particularly in reindeer-breeding Lapps. The elimination rate of Cs-137 in man was studied in the stationary whole-body counter in Lund as well as with the field-system. For the study of the performances at low and high photon energies clinical applications of methods for gastro-intestinal absorption of vitamin B12 (Co-57; 122 keV) and total body potassium determination (K-40; 1.46 MeV, K-42; 1.52 MeV) have been evaluated. Theoretical and experimental results as well as experiences of applications in radiation protection and medicine show that the scanning-bed geometry effectively evens out redistributional effects. For optimum results, however, scatter-energy pulse-ranges rather than full-energy-peak ranges should be used. (Auth.)

  19. Total Body Photography as an Aid to Skin Self-examination: A Patient's Perspective.

    Science.gov (United States)

    Secker, Lisanne J; Bergman, Wilma; Kukutsch, Nicole A

    2016-02-01

    Skin self-examination can help patients who are at high risk for developing melanoma to become more involved in their own surveillance and treatment. This study examined the use of total body photography as an aid to skin self-examination from the patients' perspective. A total of 179 individuals at high risk for developing melanoma who had undergone total body photography (60.5% response rate) completed a self-reported questionnaire assessing the frequency of skin self-examination, perceived usefulness of total body photography, and a variety of potential demographic, clinical and psychological factors. Only approximately half of the participants indicated skin self-examination as useful and 78.9% preferred clinical skin examination by a specialist. Finding total body photography useful was associated with having received instructions on how to perform skin self-examination, the use of a (hand)mirror, and confidence to detect changing moles. These findings allow us to develop strategies to further improve patients' self-screening behaviours.

  20. Osteochondroma after total body irradiation in bone marrow transplant recipients. Report of two cases

    International Nuclear Information System (INIS)

    Maeda, Go; Yokoyama, Ryohei; Ohtomo, Katsuyuki; Takayama, Jun; Beppu, Yasuo; Fukuma, Hisatoshi; Ohira, Mutsuro

    1996-01-01

    We present two cases of osteochondroma after total body irradiation in bone marrow recipients, the first in a 6-year-old boy with juvenile chronic myelogenous leukemia and the second in a 13-year-old boy with acute myelogenous leukemia. The patients developed multiple osteochondromas three years and seven years, respectively, after 12 Gy of total body irradiation. Neither had a family history of hereditary multiple osteochondromatosis. A review of the English literature revealed only one report describing five cases of osteochondroma after 12 Gy of total body irradiation in bone marrow transplant recipients. Osteochondroma should be considered as an additional adverse effect of total body irradiation. (author)

  1. Total body irradiation for children with malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Sanuki, Eiichi; Maeno, Toshio; Kamata, Rikisaburo; Tanaka, Yoshiaki; Mugishima, Hideo [Nihon Univ., Tokyo (Japan). School of Medicine

    1995-12-01

    Total body irradiation combined with high dose chemotherapy has been performed just before bone marrow transplantation in 35 children with advanced malignancies, with the object of achieving successful transplantation and improving the prognosis. Simulation was performed as follows: back scatter, flatness, dose accumulation using randophantom and dose distribution using a thermo-luminescence dosimeter and linac-graphy. The standard error of dose distribution was within 10%. In neuroblastoma, of which there were 14 cases in stage IV and one case in stage III, the 5-year survival rate was 55%. In leukemia, of which all cases were in the high-risk group (7 cases of acute lymphoblastic leukemia and 2 of acute myeloblastic leukemia) the 5-year survival rate was 55%. The 5 cases having first remission survived disease-free while the 4 cases having non-first remission died. In malignant lymphoma (6 cases in stage IV and one case in stage III, with bulky mass) the 5-year survival rate was 67%. Four cases with other diagnoses (severe aplastic anemia, and others) all survived. As yet no side effects resulting from total body irradiation have been recognized in our cases, but a longer follow-up period is necessary to observe possible late side effects. (author).

  2. Total cross section of furfural by electron impact: Experiment and theory

    Science.gov (United States)

    Traoré Dubuis, A.; Verkhovtsev, A.; Ellis-Gibbings, L.; Krupa, K.; Blanco, F.; Jones, D. B.; Brunger, M. J.; García, G.

    2017-08-01

    We present experimental total cross sections for electron scattering from furfural in the energy range from 10 to 1000 eV, as measured using a double electrostatic analyzer gas cell electron transmission experiment. These results are compared to theoretical data for furfural, as well as to experimental and theoretical values for the structurally similar molecules furan and tetrahydrofuran. The measured total cross section is in agreement with the theoretical results obtained by means of the independent-atom model with screening corrected additivity rule including interference method. In the region of higher electron energies, from 500 eV to 10 keV, the total electron scattering cross section is also estimated using a semi-empirical model based on the number of electrons and dipole polarizabilities of the molecular targets. Together with the recently measured differential and integral cross sections, and the furfural energy-loss spectra, the present total cross section data nearly complete the data set that is required for numerical simulation of low-energy electron processes in furfural, covering the range of projectile energies from a few electron volts up to 10 keV.

  3. Total cross section of furfural by electron impact: Experiment and theory.

    Science.gov (United States)

    Traoré Dubuis, A; Verkhovtsev, A; Ellis-Gibbings, L; Krupa, K; Blanco, F; Jones, D B; Brunger, M J; García, G

    2017-08-07

    We present experimental total cross sections for electron scattering from furfural in the energy range from 10 to 1000 eV, as measured using a double electrostatic analyzer gas cell electron transmission experiment. These results are compared to theoretical data for furfural, as well as to experimental and theoretical values for the structurally similar molecules furan and tetrahydrofuran. The measured total cross section is in agreement with the theoretical results obtained by means of the independent-atom model with screening corrected additivity rule including interference method. In the region of higher electron energies, from 500 eV to 10 keV, the total electron scattering cross section is also estimated using a semi-empirical model based on the number of electrons and dipole polarizabilities of the molecular targets. Together with the recently measured differential and integral cross sections, and the furfural energy-loss spectra, the present total cross section data nearly complete the data set that is required for numerical simulation of low-energy electron processes in furfural, covering the range of projectile energies from a few electron volts up to 10 keV.

  4. Observations on total-body calcium in humans with bone disease

    International Nuclear Information System (INIS)

    Spinks, T.J.; Bewley, D.K.; Ranicar, A.S.O.; Joplin, G.F.; Evans, I.M.A.; Vlotides, J.; Paolillo, M.

    1979-01-01

    Total-body calcium was measured in-vivo by neutron activation in a number of patients suffering from metabolic abnormalities which affect the skeleton. In general, less than 2% of total calcium resides in tissue other than bone allowing calcium mass to be directly related to skeletal mass. The conditions studied were (i) Paget's disease, treated with synthetic human calcitonin, (ii) osteoporosis, treated variously with calcium and phosphate supplements and 1,25 hydroxycholecalciferol, and (iii) Cushing's disease treated by pituitary implant of 198 Au or 90 Y seeds. The neutron beam used in these studies was produced by bombarding a beryllium target with deuterons accelerated in a cyclotron. The mean neutron energy was 7.5 MeV and patients received a total dose of 1 rem in about 30 s, a bilateral irradiation being employed. Measurements were made at approximately yearly intervals, the maximum period of study being about four and a half years. The precision of the method was estimated to be +-3% (SE) and a correction was applied for changes in body weight. In most patients, total calcium remained stable. However, in the Paget's patients, there was an indication of a slow upward trend while the osteoporotics (both treated and untreated) showed on average no change. Most of the patients with Cushing's disease showed no recovery of skeletal mass. Absolute calibration indicated that mean total body calcium in the Paget's patients was close to a predicted normal while that for the osteoporotic and Cushing's patients was 20-25% below this. (author)

  5. Effect of aflatoxin ingestion on total body water (T OH3 - space), total body solids A KD on some physiological and reproductive characteristics of male albino rats

    International Nuclear Information System (INIS)

    Nowar, M.S.; Eldarawany, A.A.; Habeeb, A.A.

    1992-01-01

    This investigation aimed to study the effects of aflatoxins B 1 +G 1 mixture mainly on total body water (TBW) and on total body solids (TBS) of male albino rats. Some blood components and some reproductive characteristic were also taken into consideration. Two groups, each of 8 male rats were fed the same ration. Rats of one group had been individually ingested daily with a dose of 22 μg B 1 plus 22 μg G 1 for 15 successive weeks. The obtained results showed that aflatoxin administration caused: 1- A decrease in final body weight (FBW), TBW (P<0.01) and TBS (P<0.05). 2- A decrease in serum total proteins (P<0.01), albumin (P<0.05), globulin (P<0.05), glucose (P<0.05) and increase in serum cholesterol, GOT and GPT (P<0.05) activities. 3- A decrease in each of the number of effective matings of males and delivery percentages of females mated with treated males.1 tab

  6. Correlation of total body potassium and leukemic cell mass in patients with chronic lymphocytic leukemia

    International Nuclear Information System (INIS)

    Chandra, P.; Sawitsky, A.; Chanana, A.D.; Chikkappa, G.; Cohn, S.H.; Rai, K.R.; Cronkity, E.P.

    1979-01-01

    Total body leukemic mass in patients with chronic lymphocytic leukemia (CLL) was measured by quantitation of total body potassium (TBK) with a whole-body counter. In addition, the predicted normal total body potassium (Kp) for each patient was calculated from an empirically derived relationship involving height, weight age, and sex. Both the absolute TBK and the relative excess of total body potassium (TBK/Kp) were related to the stage of disease. Patients in the early stages of CLL were found to have lower TBK and TBK/Kp than patients in the late stages of disease. Both of these parameters increased with the successively advanced stages of the disease. The clinically monitored reduction of leukemic cell mass following therapy was accompanied by reductions in TBK and TBK/Kp. Data presented support the notion that TBK/Kp is a useful indicator of the total body leukemic mass. Futhermore, the results of these studies quantitatively validate the proposed clinical staging system for CLL. Quantitation of TBK by a whole-body counter is an accurate and noninvasive procedure and does not require administration of isotopes

  7. From Talking Heads to Communicating Bodies: Cybersemiotics and Total Communication

    Directory of Open Access Journals (Sweden)

    Ole Nedergaard Thomsen

    2010-03-01

    Full Text Available Current linguistics is biased towards considering as object of scientific study only verbal language, i.e., ordinary language whose basic entities are words, sentences, and texts. By having this focus, the crucial non-verbal semiotic contributions from acts of bodily communication are left out of consideration. On the face of it, this is a strange situation, because, phenomenologically, when observing a communicating dyad, what appears to the senses is a multimodal semiotic display–the interactants produce acts of total communication, the linguistic part of which has in fact to be disentangled from the integral semiotic behavior. That a human being should in the first place be conceptualized as a ‘talking head’, rather than a ‘communicating body’, stems from at least four historically interrelated fountains: ancient Greek philosophy with its emphasis on logos as meaning both rational mind and verbal language/speech as well as with its rejection of rhetoric (including body language; Cartesian dualistic rationalism where the body was the animal, mechanistic part of a human being, unworthy for the Geisteswissenschaften; Saussure’s formal structuralism with its defocusing of the individual’s performance, parole, and its high focus on societal langue; and Chomskyan linguistics with its neglect of actual, also bodily, performance, and its total focus on an ideal mental grammatical computational competence. With the recent philosophy (‘in the flesh’ of the ‘embodied mind’, time has now come for integrating the (linguistic head with the (other part of the communicating body and seeing communication as total communication of the whole body. This means that the communicating mind is no longer restricted to its ‘rational’ aspects but has to be conceived full-scale as integrating also all kinds of ‘irrational’ factors, like emotions and motivations. Another, no less important, implication of the above is that an individual

  8. Fractionated homogenous total-body irradiation prior to bone marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Duehmke, E; Brix, F; Hebbinghaus, D; Jensen, M; Wendhausen, H; Schmitz, N

    1985-03-01

    At the University of Kiel, myeloid and acute lymphatic leukemia is treated since 1983 by total-body irradiation applied prior to bone marrow transplantation. Dose deviations in the midplane caused by the irregular surface and tissue inhomogeneities of the patient are reduced down to +-3.5% compared to the central ray, with the help of CT-based individual compensators. This method prevents above all an excessive dose to the lungs. The radiobiologic advantages of fractionated irradiation have been employed for all patients treated hitherto (n = 9). At present, a total body dose of 12 Gy in six fractions is applied within three days. There were no undesired acute radiogenic reactions except a mild acute mucositis found in all patients. Chronic side effects, especially in the lungs, were not demonstrated, too. However, the average follow-up time of 149 days has been rather short. One patient died from relapse of leukemia after a total dose of 10 Gy, another patient died because the transplanted bone marrow was rejected, and a third died from catheter sepsis. Six out of nine patients are in complete remission with a maximum index of Karnofsky. The limited experiences gained hitherto show that the homogeneous accelerated-fractionated total-body irradiation offers essential advantages compared to non-compensated single dose irradiation with respect to the prevention of undesired radiogenic effects in sound tissues and that its therapeutic efficacy is at least the same.

  9. Total body photography for skin cancer screening.

    Science.gov (United States)

    Dengel, Lynn T; Petroni, Gina R; Judge, Joshua; Chen, David; Acton, Scott T; Schroen, Anneke T; Slingluff, Craig L

    2015-11-01

    Total body photography may aid in melanoma screening but is not widely applied due to time and cost. We hypothesized that a near-simultaneous automated skin photo-acquisition system would be acceptable to patients and could rapidly obtain total body images that enable visualization of pigmented skin lesions. From February to May 2009, a study of 20 volunteers was performed at the University of Virginia to test a prototype 16-camera imaging booth built by the research team and to guide development of special purpose software. For each participant, images were obtained before and after marking 10 lesions (five "easy" and five "difficult"), and images were evaluated to estimate visualization rates. Imaging logistical challenges were scored by the operator, and participant opinion was assessed by questionnaire. Average time for image capture was three minutes (range 2-5). All 55 "easy" lesions were visualized (sensitivity 100%, 90% CI 95-100%), and 54/55 "difficult" lesions were visualized (sensitivity 98%, 90% CI 92-100%). Operators and patients graded the imaging process favorably, with challenges identified regarding lighting and positioning. Rapid-acquisition automated skin photography is feasible with a low-cost system, with excellent lesion visualization and participant acceptance. These data provide a basis for employing this method in clinical melanoma screening. © 2014 The International Society of Dermatology.

  10. Increase of Total Body Water with Decrease of Body Mass while Running 100 km Nonstop--Formation of Edema?

    Science.gov (United States)

    Knechtle, Beat; Wirth, Andrea; Knechtle, Patrizia; Rosemann, Thomas

    2009-01-01

    We investigated whether ultraendurance runners in a 100-km run suffer a decrease of body mass and whether this loss consists of fat mass, skeletal muscle mass, or total body water. Male ultrarunners were measured pre- and postrace to determine body mass, fat mass, and skeletal muscle mass by using the anthropometric method. In addition,…

  11. Total-body sodium and sodium excess

    International Nuclear Information System (INIS)

    Aloia, J.F.; Cohn, S.H.; Abesamis, C.; Babu, T.; Zanzi, I.; Ellis, K.

    1980-01-01

    Total-body levels of sodium (TBNa), chlorine (TBCI), calcium (TBCa), and potassium (TBK) were measured by neutron activation and analysis of results by whole body counting in 66 postmenopausal women. The relationship between TBNa, and TBCl, TBK, and TBCa on the one hand, and height and weight on the other, were found to compare with those previously reported. The hypothesis that TBNa and TBCl are distributed normally could not be rejected. The sodium excess (Na/sub es/) is defined as the sodium that is present in excess of that associated with the extracellular fluid (chlorine) space; the Na/sub es/ approximates nonexchangeable bone sodium. In these 66 postmenopausal women, and in patients with different endocrinopathies previously described, the values on Na/sub es/ did not differ from the normal values except in the thyrotoxicosis patients, where they were decreased. A close relationship between Na/sub es/ and TBCa was maintained in the endocrinopathies studied. This relationship was found in conditions accompanied by either an increment or a loss of skeletal mass. It appears that the NA/sub es/ value is primarily dependent upon the calcium content of bone

  12. Measurement of total-body oxygen, nitrogen, and carbon in vivo by photon activation analysis

    International Nuclear Information System (INIS)

    Ulin, K.

    1984-01-01

    With the aim of assessing nutritional status, the feasibility of measuring the total body quantities of the major body elements, i.e. oxygen, nitrogen, and carbon, using the photon beam of a 45 MV betatron and a whole-body counter, has been evaluated in detail. Following photon activation a single energy γ-radiation (.511 MeV) is observed from all three elements to be measured. The half-lives of 15 O, 13 N, and 11 C, however, are sufficiently different (20.5 min, 10.0 min, and 20.4 min. respectively) to permit their measurement from an analysis of the measured decay curve. Following corrections for interfering reactions, a computer curve-fitting algorithm is used to resolve the data into 15 O, 13 N, and 11 C components. Measurements of O, N, and C have been made both in phantoms and in live and dead rats. A comparison of the body composition results from this technique with results from chemical analysis indicates that measured carbon can quite accurately predict total body fat. The comparison of the total body nitrogen measurement by photon activation with total body protein by chemical analysis was inconclusive and suggests that further work be done to verify the estimated accuracy of the nitrogen measurement

  13. Risk management in radiotherapy: analysis for total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Banguero, Y., E-mail: ybanguero@cin.edu.uy [Universidad de la República, Montevideo (Uruguay); Píriz, G.; Guerrero, L.; Cardozo, L.; Quarneti, A. [Centro Hospital Pereira Rossell, Montevideo (Uruguay); Nader, A. [Autoridad Reguladora Nacional de Radioprotección, Montevideo (Uruguay)

    2017-07-01

    Introduction: Management of risk in any technique that is using radiation energy is very important to prevent incidents and accidents. Pretending evaluate the risk in the all process of Total Body Irradiation (TBI), this work present a risk matrix with different possible events than could occur. Methods: SEVRRA-R platform that run in windows is using to build a risk matrix separating the process of TBI in commissioning, prescription, planning and delivering dose. Any stage has a procedure with different errors associated. We build a matrix using all this information to evaluate the kind of risk we have in the technique. Results: It was obtained a template that describes in general the process of TBI with principles events, barriers and consequences. Conclusion: Analyzing the risk in any stage of the process in Total Body irradiation is a useful tool to understand the key points to work in safety for this technique. (author)

  14. The role of Tl-201 total body scintigraphy in follow up of thyroid carcinoma

    International Nuclear Information System (INIS)

    Hoefnagel, C.A.; Delprat, C.C.; Marcuse, H.R.

    1985-01-01

    To evaluate the reliability of the procedure T1-201 total body scintigraphy was performed in 294 patients (449 studies) after total thyroidectomy for thyroid carcinoma. Results were correlated with I-131-scintigraphy and tumor-marker levels (Tgb or Calcitonin/CEA). T1-201 total body scintigraphy was negative in 196 patients with no evidence of disease. T1-201-scintigraphy correctly detected tumor localizations in 24 of 30 patients with I-131-positive metastases. In 28 patients T2-201 total body scintigraphy revealed metastases which did not concentrate I-131. Histology/cytology confirmed thyroid carcinoma metastases in 16 patients and other pathology in 5 cases. 9 of 18 patients with medullary thyroid carcinoma (I-131-negative) had elevated Calcitonin/CEA-levels. The T1-201 scintigram was positive in 8 of these patients. Comparison of T1-201, I-131 and tumor markers showed that only combined use of these parameters provide complete reliability. The authors conclude that T1-201 total body scintigraphy is useful in follow up of thyroid carcinoma, especially when a discrepancy of the other parameters exists and particularly in medullary carcinoma. In long term follow up of patients who are unsuspected of disease after successful therapy for thyroid carcinoma one can rely on T1-201 total body scintigraphy in combination with tumor marker assays

  15. Radiological protection in a patient during a total body irradiation procedure

    International Nuclear Information System (INIS)

    Hernandez O, J. O.; Hinojosa G, J.; Gomez M, E.; Balam de la Vega, J. A.; Deheza V, J. C.

    2010-09-01

    A technique used in the Service of Radiotherapy of the Cancer Center of the American British Cowdray Medical Center (ABC) for the bone marrow transplantation, is the total body irradiation. It is known that the dose calculation, for this irradiation type, is old, since the dosimetric calculation is carried out by hand and they exist infinity of techniques for the patients irradiation and different forms of protecting organs of risk, as well as a great uncertainty in the given dose. In the Cancer Center of the ABC Medical Center, was carried out an irradiation procedure to total body with the following methodology: Computerized tomography of the patient total body (two vacuum mattresses in the following positions: dorsal and lateral decubitus), where is combined the two treatment techniques anterior-posterior and bilateral, skin delineate and reference volumes, dose calculation with the planning system Xi O of CMS, dose determination using an ionization chamber and a lung phantom IMRT Thorax Phantom of the mark CIRS and dosimetry in vivo. In this work is presented the used treatment technique, the results, statistics and the actualization of the patient clinical state. (Author)

  16. Measurement of total body chlorine by prompt gamma in vivo neutron activation analysis

    International Nuclear Information System (INIS)

    Beddoe, A.H.; Streat, S.J.; Hill, G.L.

    1987-01-01

    A method of measuring total body chlorine (TBCl) by prompt gamma in vivo neutron activation analysis is described depending on the same NaI(Tl) spectra used for determinations of total body nitrogen. Ratios of chlorine to hydrogen are derived and TBCl determined using a model of body composition depending on measured body weight, total body water (by tritium dilution) and protein (6.25 x nitrogen) as well as estimated body minerals and glycogen. The precision of the method based on scanning an anthropomorphic phantom is approximately 9% (SD), for a patient dose equivalent of less than 0.30 mSv. Spectra collected from 67 normal volunteers (32 male, 35 female) yielded mean values of TBCl of 72 +- 19 (SD) g in males and 53.6 +- 15 g in females, in broad agreement with values reported by workers using delayed gamma methods. Results are presented for two human cadavers analysed by neutron activation and conventional chemical analysis; the ratios of TBCl (neutron activation) to TBCl (chemical) were 0.980 +- 0.028 (SEM) and 0.91 +- 0.09. It is suggested that an improvement in precision will be achieved by increasing the scanning time (thereby increasing the radiation dose equivalent) and by adding two more detectors. (author)

  17. Seasonal changes in total body water; body composition and water turnover in reindeer

    Directory of Open Access Journals (Sweden)

    Terje S. Larsen

    1985-05-01

    Full Text Available Total body water and water turnover were measured at different times throughout the year in 3 captive Norwegian reindeer, using a tritiated water dilution method (Holleman et al. 1982. Total body water (percent of body weight increased during late autumn and winter, from 59.1 ± 1.5 % in October to 72.5 ± 2.0 % in April. Using the equatation by Pace and Rathbun (1945 for predicting total body fat (% fat = 100 - % water/0.732, this increase in total body water indicates a concomitant reduction in body fat, from a maximum value of 18.9 ± 2.6 % (of body weight in October to a minimum of 0.9 ± 2.7 % in April. During summer, on the other hand, fat content increased at the expense of a reduced percentage of body water. Water turnover was low in winter (December - April, ranging between 30.8 ± 5.2and43.6 ± 13.5ml.d-'. kg-1, but increased nearly fourfold during summer (June-August with a maximum of 117.7 ± 5.9 ml.d-1. kg-1 in August. Positive correlations between water turnover and food intake and between water turnover and ambient temperature were found, the latter probably resulting from an incidental correlation between food intake and ambient temperature.Sesongmessige forandringer i totalt kroppsvann, kropps-sammensetning og vannomsetning hos reinsdyr.Abstract in Norwegian / Sammendrag: Totalt kroppsvann og vannomsetning av vann ble målt til forskjellige årstider i 3 norske reinsdyr ved hjelp av utvasking av tritiert vann (Holleman et al. 1982. Totalt kroppsvann (prosent av kroppsvekt økte utover høsten og vinteren, fra 59.1 ± 1.5 % i oktober til 72.5 ± 2.0 % i april. Ved hjelp av en ligning som er gitt av Pace og Rathbun (1945 for beregning av totalt kroppsfett (% fett = 100 - % vann/0.732, fant en at denne økningen i vanninnhold tilsvarte en samtidig reduksjon i fettinnhold, fra en maksimums-verdi på 18.9 ± 2.6 % av kroppsvekt i oktober til et minimum på 0.9 ± 2.7 % i april. Utover sommeren økte derimot innholdet av fett p

  18. Age, gender, and race/ethnic differences in total body and subregional bone density.

    Science.gov (United States)

    Looker, A C; Melton, L J; Harris, T; Borrud, L; Shepherd, J; McGowan, J

    2009-07-01

    Total body bone density of adults from National Health and Nutrition Examination Survey (NHANES) 1999-2004 differed as expected for some groups (men>women and blacks>whites) but not others (whites>Mexican Americans). Cross-sectional age patterns in bone mineral density (BMD) of older adults differed at skeletal sites that varied by degree of weight-bearing. Total body dual-energy X-ray absorptiometry (DXA) data offer the opportunity to compare bone density of demographic groups across the entire skeleton. The present study uses total body DXA data (Hologic QDR 4500A, Hologic, Bedford MA, USA) from the NHANES 1999-2004 to examine BMD of the total body and selected skeletal subregions in a wide age range of adult men and women from three race/ethnic groups. Total body, lumbar spine, pelvis, right leg, and left arm BMD and lean mass from 13,091 adults aged 20 years and older were used. The subregions were chosen to represent sites with different degrees of weight-bearing. Mean BMD varied in expected ways for some demographic characteristics (men>women and non-Hispanic blacks>non-Hispanic whites) but not others (non-Hispanic whites>Mexican Americans). Differences in age patterns in BMD also emerged for some characteristics (sex) but not others (race/ethnicity). Differences in cross-sectional age patterns in BMD and lean mass by degree of weight-bearing in older adults were observed for the pelvis, leg, and arm. This information may be useful for generating hypotheses about age, race, and sex differences in fracture risk in the population.

  19. Total body skeletal muscle mass: estimation by creatine (methyl-d3) dilution in humans

    Science.gov (United States)

    Walker, Ann C.; O'Connor-Semmes, Robin L.; Leonard, Michael S.; Miller, Ram R.; Stimpson, Stephen A.; Turner, Scott M.; Ravussin, Eric; Cefalu, William T.; Hellerstein, Marc K.; Evans, William J.

    2014-01-01

    Current methods for clinical estimation of total body skeletal muscle mass have significant limitations. We tested the hypothesis that creatine (methyl-d3) dilution (D3-creatine) measured by enrichment of urine D3-creatinine reveals total body creatine pool size, providing an accurate estimate of total body skeletal muscle mass. Healthy subjects with different muscle masses [n = 35: 20 men (19–30 yr, 70–84 yr), 15 postmenopausal women (51–62 yr, 70–84 yr)] were housed for 5 days. Optimal tracer dose was explored with single oral doses of 30, 60, or 100 mg D3-creatine given on day 1. Serial plasma samples were collected for D3-creatine pharmacokinetics. All urine was collected through day 5. Creatine and creatinine (deuterated and unlabeled) were measured by liquid chromatography mass spectrometry. Total body creatine pool size and muscle mass were calculated from D3-creatinine enrichment in urine. Muscle mass was also measured by magnetic resonance imaging (MRI), dual-energy x-ray absorptiometry (DXA), and traditional 24-h urine creatinine. D3-creatine was rapidly absorbed and cleared with variable urinary excretion. Isotopic steady-state of D3-creatinine enrichment in the urine was achieved by 30.7 ± 11.2 h. Mean steady-state enrichment in urine provided muscle mass estimates that correlated well with MRI estimates for all subjects (r = 0.868, P creatine dose determined by urine D3-creatinine enrichment provides an estimate of total body muscle mass strongly correlated with estimates from serial MRI with less bias than total lean body mass assessment by DXA. PMID:24764133

  20. Calibration of whole-body counters for transuranic radionuclides by using total-body donations to the United States Transuranium Registry

    International Nuclear Information System (INIS)

    Palmer, H.E.; Heid, K.R.; Breitenstein, B.D.; Durbin, P.W.; McInroy, J.F.

    1985-01-01

    One of the many benefits of the whole-body donation programme of the United States Transuranium Registry is the calibration of whole-body counters by measuring a donated body containing radioactivity before radiochemical analysis of the body occurs. These measurements have provided the best existing calibration factors for measuring 241 Am and 239 Pu in the skeleton of living people. In one case where the body contained an easily measurable quantity of 241 Am, the 241 Am content was found to be the same for identical bones on the right and left sides of the body. The bones from the right side of the body and every other vertebrae were radiochemically analysed and the bones from the left side were reserved. These latter have a known quantity of naturally distributed 241 Am based on the analysis of bones from the right side. These reserved bones are being incorporated into tissue equivalent body parts for future calibrations and interlaboratory comparisons. The measurements on the total body and the reserved bones have already been very useful in determining the contribution of skeletal activity to that of lung measurements and determining a calibration factor for measuring 239 Pu deposited in the skeleton. In the future it is planned to periodically make in vivo measurements on those people participating in the total-body donation programme so that calibration factors can be obtained for lung and liver content after subsequent analysis of these tissues. (author)

  1. Investigation into the relationship between body surface area and total body potassium using Monte Carlo and measurement

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, J.A. [Medical Physics and Imaging, Queen Elizabeth Hospital, Birmingham (United Kingdom)]. E-mail: jane.rogers@university-b.wmids.nhs.uk; Blake-James, M. [School of Physics and Astronomy, University of Birmingham, Birmingham (United Kingdom); Green, S.; Beddoe, A.H. [Medical Physics and Imaging, Queen Elizabeth Hospital, Birmingham (United Kingdom)

    2002-03-07

    The use of body surface area (BSA) as a means of indexing chemotherapy doses is widespread even though the value of this practice is uncertain. In principle, the body cell mass (BCM) more closely represents the body's metabolic size and this is investigated here as an alternative to BSA; since 98% of body potassium is intracellular the derivation of total body potassium (TBK) via the measurement of {sup 40}K in a whole body counter (WBC) will provide a useful normalizing index for metabolic size, potentially avoiding toxicity and underdosing. The Queen Elizabeth Hospital WBC has been used in this study, initially involving single geometrical phantoms and then combinations of these to simulate human body habitus. Monte Carlo N-particle (MCNP) codes were constructed to model the phantoms and simulate the measurements made in the WBC. Efficiency corrections were derived by comparing measurement and modelled data for each detector separately. A method of modelling a person in the WBC as a series of ellipsoids was developed. Twenty-four normal males and 24 females were measured for their {sup 40}K emissions. Individual MCNP codes were constructed for each volunteer and the results used in conjunction with the measurements to derive TBK, correcting for body habitus effects and detector efficiencies. An estimate of the component of error arising from sources other than counting statistics was included by analysing data from the measurement of phantoms. The total residual errors (expressed as coefficients of variation) for males and females were 10.1% and 8.5% respectively. The measurement components were determined to be 2.4% and 2.5%, implying that the biological components were 9.8% and 8.1% respectively. These results suggest that the use of BSA for indexing chemotherapy doses is likely to give rise to clinically significant under- or overdosing. (author)

  2. Clinical Perspective of 3D Total Body Photography for Early Detection and Screening of Melanoma.

    Science.gov (United States)

    Rayner, Jenna E; Laino, Antonia M; Nufer, Kaitlin L; Adams, Laura; Raphael, Anthony P; Menzies, Scott W; Soyer, H Peter

    2018-01-01

    Melanoma incidence continues to increase across many populations globally and there is significant mortality associated with advanced disease. However, if detected early, patients have a very promising prognosis. The methods that have been utilized for early detection include clinician and patient skin examinations, dermoscopy (static and sequential imaging), and total body photography via 2D imaging. Total body photography has recently witnessed an evolution from 2D imaging with the ability to now create a 3D representation of the patient linked with dermoscopy images of individual lesions. 3D total body photography is a particularly beneficial screening tool for patients at high risk due to their personal or family history or those with multiple dysplastic naevi-the latter can make monitoring especially difficult without the assistance of technology. In this perspective, we discuss clinical examples utilizing 3D total body photography, associated advantages and limitations, and future directions of the technology. The optimal system for melanoma screening should improve diagnostic accuracy, be time and cost efficient, and accessible to patients across all demographic and socioeconomic groups. 3D total body photography has the potential to address these criteria and, most importantly, optimize crucial early detection.

  3. Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient Care.

    Science.gov (United States)

    Cherry, Simon R; Jones, Terry; Karp, Joel S; Qi, Jinyi; Moses, William W; Badawi, Ramsey D

    2018-01-01

    PET is widely considered the most sensitive technique available for noninvasively studying physiology, metabolism, and molecular pathways in the living human being. However, the utility of PET, being a photon-deficient modality, remains constrained by factors including low signal-to-noise ratio, long imaging times, and concerns about radiation dose. Two developments offer the potential to dramatically increase the effective sensitivity of PET. First by increasing the geometric coverage to encompass the entire body, sensitivity can be increased by a factor of about 40 for total-body imaging or a factor of about 4-5 for imaging a single organ such as the brain or heart. The world's first total-body PET/CT scanner is currently under construction to demonstrate how this step change in sensitivity affects the way PET is used both in clinical research and in patient care. Second, there is the future prospect of significant improvements in timing resolution that could lead to further effective sensitivity gains. When combined with total-body PET, this could produce overall sensitivity gains of more than 2 orders of magnitude compared with existing state-of-the-art systems. In this article, we discuss the benefits of increasing body coverage, describe our efforts to develop a first-generation total-body PET/CT scanner, discuss selected application areas for total-body PET, and project the impact of further improvements in time-of-flight PET. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  4. Rotational total skin electron irradiation with a linear accelerator

    Science.gov (United States)

    Evans, Michael D.C.; Devic, Slobodan; Parker, William; Freeman, Carolyn R.; Roberge, David; Podgorsak, Ervin B.

    2008-01-01

    The rotational total skin electron irradiation (RTSEI) technique at our institution has undergone several developments over the past few years. Replacement of the formerly used linear accelerator has prompted many modifications to the previous technique. With the current technique, the patient is treated with a single large field while standing on a rotating platform, at a source‐to‐surface distance of 380 cm. The electron field is produced by a Varian 21EX linear accelerator using the commercially available 6 MeV high dose rate total skin electron mode, along with a custom‐built flattening filter. Ionization chambers, radiochromic film, and MOSFET (metal oxide semiconductor field effect transistor) detectors have been used to determine the dosimetric properties of this technique. Measurements investigating the stationary beam properties, the effects of full rotation, and the dose distributions to a humanoid phantom are reported. The current treatment technique and dose regimen are also described. PACS numbers: 87.55.ne, 87.53.Hv, 87.53.Mr

  5. Gastrointestinal decontamination of dogs treated with total body irradiation and bone marrow transplantation

    NARCIS (Netherlands)

    Vriesendorp, H.M.; Heidt, P.J.; Zurcher, C.

    1981-01-01

    Procedures for total and selective gastrointestinal decontamination of dogs are described. The selective procedure removed only Gram negative aerobic bacteria, yeast and fungi. Dogs receiving total decontamination were less susceptible to the GI syndrome following total body irradiation (TBI) than

  6. Integral elastic, electronic-state, ionization, and total cross sections for electron scattering with furfural

    Science.gov (United States)

    Jones, D. B.; da Costa, R. F.; Varella, M. T. do N.; Bettega, M. H. F.; Lima, M. A. P.; Blanco, F.; García, G.; Brunger, M. J.

    2016-04-01

    We report absolute experimental integral cross sections (ICSs) for electron impact excitation of bands of electronic-states in furfural, for incident electron energies in the range 20-250 eV. Wherever possible, those results are compared to corresponding excitation cross sections in the structurally similar species furan, as previously reported by da Costa et al. [Phys. Rev. A 85, 062706 (2012)] and Regeta and Allan [Phys. Rev. A 91, 012707 (2015)]. Generally, very good agreement is found. In addition, ICSs calculated with our independent atom model (IAM) with screening corrected additivity rule (SCAR) formalism, extended to account for interference (I) terms that arise due to the multi-centre nature of the scattering problem, are also reported. The sum of those ICSs gives the IAM-SCAR+I total cross section for electron-furfural scattering. Where possible, those calculated IAM-SCAR+I ICS results are compared against corresponding results from the present measurements with an acceptable level of accord being obtained. Similarly, but only for the band I and band II excited electronic states, we also present results from our Schwinger multichannel method with pseudopotentials calculations. Those results are found to be in good qualitative accord with the present experimental ICSs. Finally, with a view to assembling a complete cross section data base for furfural, some binary-encounter-Bethe-level total ionization cross sections for this collision system are presented.

  7. Computer-based anthropometrical system for total body irradiation.

    Science.gov (United States)

    Sánchez-Nieto, B; Sánchez-Doblado, F; Terrón, J A; Arráns, R; Errazquin, L

    1997-05-01

    For total body irradiation (TBI) dose calculation requirements, anatomical information about the whole body is needed. Despite the fact that video image grabbing techniques are used by some treatment planning systems for standard radiotherapy, there are no such systems designed to generate anatomical parameters for TBI planning. The paper describes an anthropometrical computerised system based on video image grabbing which was purpose-built to provide anatomical data for a PC-based TBI planning system. Using software, the system controls the acquisition and digitalisation of the images (external images of the patient in treatment position) and the measurement procedure itself (on the external images or the digital CT information). An ASCII file, readable by the TBI planning system, is generated to store the required parameters of the dose calculation points, i.e. depth, backscatter tissue thickness, thickness of inhomogeneity, off-axis distance (OAD) and source to skin distance (SSD).

  8. Total cross sections for positron and electron scattering from pyrimidine

    International Nuclear Information System (INIS)

    Zecca, A; Chiari, L; Trainotti, E; GarcIa, G; Blanco, F; Brunger, M J

    2010-01-01

    In this paper we report original measurements of total cross sections for positron scattering from the important biomolecule pyrimidine. The energy range of these measurements was 0.3-45 eV, while the energy resolution was ∼260 meV. In addition, we report theoretical results, calculated within the independent atom-screened additivity rule (IAM-SCAR) formalism, for the corresponding electron impact total cross sections. In that case the energy range is 1-10 000 eV. Total cross sections are very important input data for codes that seek to simulate charged-particle tracks in matter, as they define the mean-free path between collisions. As the present data and computations are to the best of our knowledge the first total cross sections to be reported for either positron or electron scattering from pyrimidine, they fill an important void in our available knowledge in the literature.

  9. Dose calculation method with 60-cobalt gamma rays in total body irradiation

    International Nuclear Information System (INIS)

    Scaff, Luiz Alberto Malaguti

    2001-01-01

    Physical factors associated to total body irradiation using 60 Co gamma rays beams, were studied in order to develop a calculation method of the dose distribution that could be reproduced in any radiotherapy center with good precision. The method is based on considering total body irradiation as a large and irregular field with heterogeneities. To calculate doses, or doses rates, of each area of interest (head, thorax, thigh, etc.), scattered radiation is determined. It was observed that if dismagnified fields were considered to calculate the scattered radiation, the resulting values could be applied on a projection to the real size to obtain the values for dose rate calculations. In a parallel work it was determined the variation of the dose rate in the air, for the distance of treatment, and for points out of the central axis. This confirm that the use of the inverse square law is not valid. An attenuation curve for a broad beam was also determined in order to allow the use of absorbers. In this work all the adapted formulas for dose rate calculations in several areas of the body are described, as well time/dose templates sheets for total body irradiation. The in vivo dosimetry, proved that either experimental or calculated dose rate values (achieved by the proposed method), did not have significant discrepancies. (author)

  10. The Role of Electron Transport and Trapping in MOS Total-Dose Modeling

    International Nuclear Information System (INIS)

    Fleetwood, D.M.; Winokur, P.S.; Riewe, L.C.; Flament, O.; Paillet, P.; Leray, J.L.

    1999-01-01

    Radiation-induced hole and electron transport and trapping are fundamental to MOS total-dose models. Here we separate the effects of electron-hole annihilation and electron trapping on the neutralization of radiation-induced charge during switched-bias irradiation for hard and soft oxides, via combined thermally stimulated current (TSC) and capacitance-voltage measurements. We also show that present total-dose models cannot account for the thermal stability of deeply trapped electrons near the Si/SiO 2 interface, or the inability of electrons in deep or shallow traps to contribute to TSC at positive bias following (1) room-temperature, (2) high-temperature, or (3) switched-bias irradiation. These results require revisions of modeling parameters and boundary conditions for hole and electron transport in SiO 2 . The nature of deep and shallow electron traps in the near-interfacial SiO 2 is discussed

  11. EXPLORER: Changing the molecular imaging paradigm with total-body PET/CT (Conference Presentation)

    Science.gov (United States)

    Cherry, Simon R.; Badawi, Ramsey D.; Jones, Terry

    2016-04-01

    Positron emission tomography (PET) is the highest sensitivity technique for human whole-body imaging studies. However, current clinical PET scanners do not make full use of the available signal, as they only permit imaging of a 15-25 cm segment of the body at one time. Given the limited sensitive region, whole-body imaging with clinical PET scanners requires relatively long scan times and subjects the patient to higher than necessary radiation doses. The EXPLORER initiative aims to build a 2-meter axial length PET scanner to allow imaging the entire subject at once, capturing nearly the entire available PET signal. EXPLORER will acquire data with ~40-fold greater sensitivity leading to a six-fold increase in reconstructed signal-to-noise ratio for imaging the total body. Alternatively, total-body images with the EXPLORER scanner will be able to be acquired in ~30 seconds or with ~0.15 mSv injected dose, while maintaining current PET image quality. The superior sensitivity will open many new avenues for biomedical research. Specifically for cancer applications, high sensitivity PET will enable detection of smaller lesions. Additionally, greater sensitivity will allow imaging out to 10 half-lives of positron emitting radiotracers. This will enable 1) metabolic ultra-staging with FDG by extending the uptake and clearance time to 3-5 hours to significantly improve contrast and 2) improved kinetic imaging with short-lived radioisotopes such as C-11, crucial for drug development studies. Frequent imaging studies of the same subject to study disease progression or to track response to therapy will be possible with the low dose capabilities of the EXPLORER scanner. The low dose capabilities will also open up new imaging possibilities in pediatrics and adolescents to better study developmental disorders. This talk will review the basis for developing total-body PET, potential applications, and review progress to date in developing EXPLORER, the first total-body PET scanner.

  12. A Large Rice Body-Containing Cyst Mimicking Infection following Total Hip Arthroplasty: A Case Report

    Directory of Open Access Journals (Sweden)

    Wael Bayoud

    2017-01-01

    Full Text Available Introduction. Soft tissue mass following total hip arthroplasty raises several differential diagnoses not limited to infection, hematoma, wear debris, malignancy, and bursitis. Rice body formation in the hip region is an uncommon process denoting a chronic inflammation. We report here the second case of its kind in the medical literature of a wide symptomatic rice-like body cyst complicating a total hip arthroplasty. Case Presentation. This is the case of an 82-year-old white female, presenting with a warm, red, and inflated groin five years after revision of right total hip arthroplasty. Surgical intervention reveals a large well circumscribed cyst containing well-organized rice-like bodies. This eventuality was never reported in differential diagnosis of hip periprosthetic soft tissue masses before. Conclusion. This case report helps widening the array of the differential diagnosis in patients presenting with a slow growing soft tissue mass following total hip arthroplasty, making rice-like bodies cyst a valid one to consider.

  13. Biological basis of total body irradiation

    International Nuclear Information System (INIS)

    Dubray, B.; Helfre, S.; Dendale, R.; Cosset, J.M.; Giraud, P.

    1999-01-01

    A comprehensive understanding of the radiobiological bases of total body irradiation (TBI) is made difficult by the large number of normal and malignant tissues that must be taken into account. In addition, tissue responses to irradiation are also sensitive to associated treatments, type of graft and a number of patient characteristics. Experimental studies have yielded a large body of data, the clinical relevance of which still requires definite validation through randomized trials. Fractionated TBI schemes are able to reduce late normal tissue toxicity, but the ultimate consequences of the fractional dose reduction do not appear to be equivocal. Thus, leukemia and lymphoma cells are probably more radio-biologically heterogeneous than previously thought, with several cell lines displaying relatively high radioresistance and repair capability patterns. The most primitive host-type hematopoietic stem cells are likely to be at least partly protected by TBI fractionation and may hamper late engraftment. Similarly, but with possibly conflicting consequences on the probability of engraftment, the persistence of a functional marrow stroma may also be fractionation-sensitive, while higher rejection rates have been reported after T-depletion grafts and fractionated TBI. in clinical practice (as for performance of relevant clinical trials), the influence of these results are rather limited by the heavy logistic constraints created by a sophisticated and time-consuming procedure. Lastly, clinicians are now facing an increasing incidence of second cancers, at least partly induced by irradiation, which jeopardize the long-term prospects of otherwise cured patients. (authors)

  14. Ciliary body toxicities of systemic oxcarbazepine and valproic acid treatments: electron microscopic study.

    Science.gov (United States)

    Göktaş, Güleser; Aktaş, Zeynep; Erdoğan, Deniz; Seymen, Cemile Merve; Karaca, Emine Esra; Cansu, Ali; Serdaroğlu, Ayşe; Kaplanoğlu, Gülnur Take

    2015-01-01

    Ciliary body is responsible for humour aqueous production in posterior chamber. Valproic acid (VPA) has been widely used for the treatment of epilepsy and other neuropsychiatric diseases such as bipolar disease and major depression. Oxcarbazepine (OXC) is a new anti-epileptic agent that has been used recently for childhood epilepsies such as VPA. In this study, we aimed to investigate the effects of VPA and OXC treatments used as antiepileptic in ciliary body by electron microscopy. In our study, 40 Wistar rats (21 days old) were divided equally into four groups which were applied saline (group 1), VPA (group 2), OXC (group 3) and VPA + OXC (group 4). The as-prepared ocular tissues were characterized by transmission electron microscopy (TEM) technique in scanning and transmission electron microscopy (SEM-TEM) (Carl Zeiss EVO LS10). The results confirmed that VPA caused dense ciliary body degeneration. Additionally, ciliary body degeneration in group 4 was supposed to be due to VPA treatment. Ciliary body damage and secondary outcomes should be considered in patients with long-term VPA therapy.

  15. Appraisal of ANN and ANFIS for Predicting Vertical Total Electron ...

    African Journals Online (AJOL)

    Positional accuracy in the usage of GPS receiver is one of the major challenges in GPS observations. The propagation of the GPS signals are interfered by free electrons which are the massive particles in the ionosphere region and results in delays in the transmission of signals to the Earth. Therefore, the total electron ...

  16. Monte Carlo efficiency calibration of a neutron generator-based total-body irradiator

    International Nuclear Information System (INIS)

    Shypailo, R.J.; Ellis, K.J.

    2009-01-01

    Many body composition measurement systems are calibrated against a single-sized reference phantom. Prompt-gamma neutron activation (PGNA) provides the only direct measure of total body nitrogen (TBN), an index of the body's lean tissue mass. In PGNA systems, body size influences neutron flux attenuation, induced gamma signal distribution, and counting efficiency. Thus, calibration based on a single-sized phantom could result in inaccurate TBN values. We used Monte Carlo simulations (MCNP-5; Los Alamos National Laboratory) in order to map a system's response to the range of body weights (65-160 kg) and body fat distributions (25-60%) in obese humans. Calibration curves were constructed to derive body-size correction factors relative to a standard reference phantom, providing customized adjustments to account for differences in body habitus of obese adults. The use of MCNP-generated calibration curves should allow for a better estimate of the true changes in lean tissue mass that many occur during intervention programs focused only on weight loss. (author)

  17. Using Three-Body Recombination to Extract Electron Temperatures of Ultracold Plasmas

    International Nuclear Information System (INIS)

    Fletcher, R. S.; Zhang, X. L.; Rolston, S. L.

    2007-01-01

    Three-body recombination, an important collisional process in plasmas, increases dramatically at low electron temperatures, with an accepted scaling of T e -9/2 . We measure three-body recombination in an ultracold neutral xenon plasma by detecting recombination-created Rydberg atoms using a microwave-ionization technique. With the accepted theory (expected to be applicable for weakly coupled plasmas) and our measured rates, we extract the plasma temperatures, which are in reasonable agreement with previous measurements early in the plasma lifetime. The resulting electron temperatures indicate that the plasma continues to cool to temperatures below 1 K

  18. Printed soft-electronics for remote body monitoring

    Science.gov (United States)

    Mantysalo, Matti; Vuorinen, Tiina; Jeihani, Vala; Vehkaoja, Antti

    2017-08-01

    Wearable electronics has emerged into the consumer markets over the past few years. Wrist worn and textile integrated devices are the most common apparatuses for unobtrusive monitoring in sports and wellness sectors. Disposable patches and bandages, however, represent the new era of wearable electronics. Soft and stretchable electronics is the enabling technology of this paradigm shift. It can conform to temporary transfer tattoo and deform with the skin without detachment or fracture. In this paper, we focus on screen-printed soft-electronics for remote body monitoring. We will present a fabrication process of a skin conformable electrode bandage designed for long-term outpatient electrocardiography (ECG) monitoring. The soft bandage is designed to be attached to the patient chest and miniaturized data collection device is connected to the bandage via Micro-USB connector. The fabricated bandage is tested in short exercise as well as continued long-term (72 hours) monitoring during normal daily activities. The attained quality of the measured ECG signals is fully satisfactory for rhythm-based cardiac analysis also during moderate-intensity exercise. After pre-processing, the signals could be used also for more profound morphological analysis of ECG wave shapes.

  19. Body of Knowledge for Silicon Carbide Power Electronics

    Science.gov (United States)

    Boomer, Kristen; Lauenstein, Jean-Marie; Hammoud, Ahmad

    2016-01-01

    Wide band gap semiconductors, such as silicon carbide (SiC), have emerged as very promising materials for future electronic components due to the tremendous advantages they offer in terms of power capability, extreme temperature tolerance, and high frequency operation. This report documents some issues pertaining to SiC technology and its application in the area of power electronics, in particular those geared for space missions. It also serves as a body of knowledge (BOK) in reference to the development and status of this technology obtained via literature and industry survey as well as providing a listing of the major manufacturers and their capabilities. Finally, issues relevant to the reliability of SiC-based electronic parts are addressed and limitations affecting the full utilization of this technology are identified.

  20. Integral elastic, electronic-state, ionization, and total cross sections for electron scattering with furfural

    Energy Technology Data Exchange (ETDEWEB)

    Jones, D. B. [School of Chemical and Physical Sciences, Flinders University, GPO Box 2100, Adelaide, South Australia 5001 (Australia); Costa, R. F. da [Instituto de Física “Gleb Wataghin,” Universidade Estadual de Campinas, Campinas, 13083-859 São Paulo (Brazil); Departamento de Física, Universidade Federal do Espírito Santo, 29075-910, Vitória, Espírito Santo (Brazil); Varella, M. T. do N. [Instituto de Física, Universidade de São Paulo, CP 66318, 05315-970 São Paulo (Brazil); Bettega, M. H. F. [Departamento de Física, Universidade Federal do Paraná, CP 19044, 81531-990 Curitiba, Paraná (Brazil); Lima, M. A. P. [Instituto de Física “Gleb Wataghin,” Universidade Estadual de Campinas, Campinas, 13083-859 São Paulo (Brazil); Blanco, F. [Departamento de Física Atómica, Molecular y Nuclear, Universidad Complutense de Madrid, Madrid E-28040 (Spain); García, G. [Instituto de Física Fundamental, CSIC, Serrano 113-bis, 28006 Madrid (Spain); Brunger, M. J., E-mail: Michael.Brunger@flinders.edu.au [School of Chemical and Physical Sciences, Flinders University, GPO Box 2100, Adelaide, South Australia 5001 (Australia); Institute of Mathematical Sciences, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2016-04-14

    We report absolute experimental integral cross sections (ICSs) for electron impact excitation of bands of electronic-states in furfural, for incident electron energies in the range 20–250 eV. Wherever possible, those results are compared to corresponding excitation cross sections in the structurally similar species furan, as previously reported by da Costa et al. [Phys. Rev. A 85, 062706 (2012)] and Regeta and Allan [Phys. Rev. A 91, 012707 (2015)]. Generally, very good agreement is found. In addition, ICSs calculated with our independent atom model (IAM) with screening corrected additivity rule (SCAR) formalism, extended to account for interference (I) terms that arise due to the multi-centre nature of the scattering problem, are also reported. The sum of those ICSs gives the IAM-SCAR+I total cross section for electron–furfural scattering. Where possible, those calculated IAM-SCAR+I ICS results are compared against corresponding results from the present measurements with an acceptable level of accord being obtained. Similarly, but only for the band I and band II excited electronic states, we also present results from our Schwinger multichannel method with pseudopotentials calculations. Those results are found to be in good qualitative accord with the present experimental ICSs. Finally, with a view to assembling a complete cross section data base for furfural, some binary-encounter-Bethe-level total ionization cross sections for this collision system are presented.

  1. Integral elastic, electronic-state, ionization, and total cross sections for electron scattering with furfural

    International Nuclear Information System (INIS)

    Jones, D. B.; Costa, R. F. da; Varella, M. T. do N.; Bettega, M. H. F.; Lima, M. A. P.; Blanco, F.; García, G.; Brunger, M. J.

    2016-01-01

    We report absolute experimental integral cross sections (ICSs) for electron impact excitation of bands of electronic-states in furfural, for incident electron energies in the range 20–250 eV. Wherever possible, those results are compared to corresponding excitation cross sections in the structurally similar species furan, as previously reported by da Costa et al. [Phys. Rev. A 85, 062706 (2012)] and Regeta and Allan [Phys. Rev. A 91, 012707 (2015)]. Generally, very good agreement is found. In addition, ICSs calculated with our independent atom model (IAM) with screening corrected additivity rule (SCAR) formalism, extended to account for interference (I) terms that arise due to the multi-centre nature of the scattering problem, are also reported. The sum of those ICSs gives the IAM-SCAR+I total cross section for electron–furfural scattering. Where possible, those calculated IAM-SCAR+I ICS results are compared against corresponding results from the present measurements with an acceptable level of accord being obtained. Similarly, but only for the band I and band II excited electronic states, we also present results from our Schwinger multichannel method with pseudopotentials calculations. Those results are found to be in good qualitative accord with the present experimental ICSs. Finally, with a view to assembling a complete cross section data base for furfural, some binary-encounter-Bethe-level total ionization cross sections for this collision system are presented.

  2. Total cross sections for electron scattering with halocarbon molecules

    Energy Technology Data Exchange (ETDEWEB)

    Naghma, Rahla; Gupta, Dhanoj; Antony, Bobby, E-mail: bka.ism@gmail.com

    2014-03-01

    Highlights: • A quantum mechanical model to find elastic, inelastic and total CS by e{sup −} impact. • Spherical complex optical potential formalism is used to find total CS. • Result shows consistency and good agreement with previous data wherever available. • Maiden attempt to find CS for CH{sub 2}Br{sub 2}, CHBr{sub 3}, CBr{sub 4} and C{sub n}H{sub 2n+1}Cl (n = 2–4) molecules. • Interesting correlation observed between total CS and polarizability of the molecule. - Abstract: A theoretical study on electron collision with chlorinated methanes: CH{sub 2}Cl{sub 2} and CHCl{sub 3}, brominated methanes: CH{sub 2}Br{sub 2}, CHBr{sub 3} and CBr{sub 4} and some mono chloroalkanes: C{sub n}H{sub 2n+1}Cl (n = 2–4) molecules in gaseous ground state is undertaken to report elastic, inelastic and total cross sections in the 20–5000 eV energy range. The target molecule is represented as a sum of various scattering centres, which are assumed to scatter electrons independently. The spherical complex optical potential (SCOP) is formulated to represent the interaction dynamics between the electron and the constituent scattering centres. Using SCOP, the quantum mechanical scattering problem is solved through partial wave analysis. The results obtained for CH{sub 2}Cl{sub 2} and CHCl{sub 3} are compared with the available experimental and theoretical values. The elastic cross section for CBr{sub 4} shows satisfactory agreement with the previous available data. The cross sections for CH{sub 2}Br{sub 2}, CHBr{sub 3}, and C{sub n}H{sub 2n+1}Cl (n = 2–4) molecules presented in this work are reported for the first time.

  3. Total body irradiation in hematopoietic stem cell transplantation

    Directory of Open Access Journals (Sweden)

    Fundagul Andic

    2014-06-01

    Full Text Available Total body irradiation is used in conjunction with chemotherapy as a conditioning regimen in the treatment of many disease such as leukemia, myelodysplastic syndrome, aplastic anemia, multiple myeloma and lymphoma prior to the hematopoetic stem cell transplantation. The main purposes of the hematopoetic stem cell transplantation are eradication of the recipient bone marrow and any residual cancer cells, creation of space in the receipient bone marrow for donor hematopoetic stem cells, and immunosuppression to prevent rejection of donor stem cells in the case of an allotransplant. [Archives Medical Review Journal 2014; 23(3.000: 398-410

  4. Serum immunoglobulin levels in humans exposed to therapeutic total-body gamma irradiation

    International Nuclear Information System (INIS)

    Chaskes, S.; Kingdon, G.C.; Balish, E.

    1975-01-01

    Reduced serum immunoglobulin (IgA, IgG, IgM) levels developed in the majority of 27 patients with hematologic disorders after treatment with 100 to 350 R total-body gamma-ray exposures at a dose rate of either 1.5 R/min to 1.5 R/hr. A reduction in IgA of 20 percent or more was found in 66 percent of the cases, while 56 percent showed an IgM decrease, and 49 percent an IgG decrease of 20 percent. The severity of immunoglobulin depression was influenced by the total radiation dose and the patient's primary disease. The occurrence of IgG and IgM depression was greater when the radiation was given at 1.5 R/hr than when the dose rate was 1.5 R/min. Substantial but incomplete recovery toward preirradiation immunoglobulin levels was found for most patients by 7 wk after total-body irradiation (TBI). (U.S.)

  5. Many-body effects in X-ray photoemission spectroscopy and electronic properties of solids

    International Nuclear Information System (INIS)

    Kohiki, S.

    1999-01-01

    Photoemission from a solid is evidently a many-body process since the motion of each electron cannot be independent of the motions of other electrons. In this article we review the reported many-body effects in X-ray photoemission such as extra-atomic relaxation energy, charge transfer satellite and energy loss structure which are informative in relation to the characteristics of solids. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  6. Long-term trends in the total electron content

    Czech Academy of Sciences Publication Activity Database

    Laštovička, Jan; Urbář, Jaroslav; Kozubek, Michal

    2017-01-01

    Roč. 44, č. 16 (2017), s. 8186-8172 ISSN 0094-8276 R&D Projects: GA ČR(CZ) GA15-03909S Institutional support: RVO:68378289 Keywords : total electron content * long-term trend * solar control Subject RIV: DG - Athmosphere Sciences, Meteorology OBOR OECD: Climatic research Impact factor: 4.253, year: 2016 http://onlinelibrary.wiley.com/doi/10.1002/2017GL075063/full

  7. Comparison of nodal staging with lean body mass based and with total body weight based in lung cancer

    International Nuclear Information System (INIS)

    Lee, H. Y.; Chung, J. K.; Kang, W. J.; So, Y.; Lee, D. S.; Lee, M. C.

    2004-01-01

    The standardized uptake (SUV) is semiquantitative evaluation parameter in positron emission tomography (PET). But there is no consensus about the application or process of SUV measurement. In this study, we used measured lean body mass (LBM) and total weight for application in SUV measurement. Also we compared the each nodal staging with SUV between measured LBM, and total weight, in non small cell lung cancer (NSCLC). Total 21 patients with lung cancer were enrolled (M:F=17:4, age 45[+-]8 years). PET-CT was done before operation with Gemini (Philips, Milpitas, U.S.). Each image was reconstructed twice with measured weight and lean body mass. Maximum SUVs of 103 dissected lymph nodes were measured and compared with histological result. For the deciding on the cut off value, receiver operating characteristic (ROC) analysis was done. 14 lymph nodes in the 103 dissected lymph nodes were metastatic lesions. From the ROC analysis, the cut off value of SUV was 1.7 with measured LBM and 2.3 with total weight. With measured LBM, Sensitivity and specificity were 92.5%. 78.2% and area under curve was 0.881. With total weight, sensitivity and specificity was 92.5% and 77%, Area under curve was 0.859. The normalization of SUV could be done with measured LBM. With the normalization of SUV with LBM, the nodal staging of NSCLC using SUV could be more accurate than using total weight in the reconstruction and measurement of SUV for lymph node lesions

  8. Total body neutron activation analysis of calcium: calibration and normalisation

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, N S.J.; Eastell, R; Ferrington, C M; Simpson, J D; Strong, J A [Western General Hospital, Edinburgh (UK); Smith, M A; Tothill, P [Royal Infirmary, Edinburgh (UK)

    1982-05-01

    An irradiation system has been designed, using a neutron beam from a cyclotron, which optimises the uniformity of activation of calcium. Induced activity is measured in a scanning, shadow-shield whole-body counter. Calibration has been effected and reproducibility assessed with three different types of phantom. Corrections were derived for variations in body height, depth and fat thickness. The coefficient of variation for repeated measurements of an anthropomorphic phantom was 1.8% for an absorbed dose equivalent of 13 mSv (1.3 rem). Measurements of total body calcium in 40 normal adults were used to derive normalisation factors which predict the normal calcium in a subject of given size and age. The coefficient of variation of normalised calcium was 6.2% in men and 6.6% in women, with the demonstration of an annual loss of 1.5% after the menopause. The narrow range should make single measurements useful for diagnostic purposes.

  9. Phase-II trial of fractionated total body radiation in bone marrow transplantation for acute leukemia

    International Nuclear Information System (INIS)

    Gale, R.P.; Opelz, G.; Feig, S.

    1979-01-01

    The addition of low doses of fractionated total body irradiation and a radiosensitizing agent to more conventional doses of total body irradiation was well tolerated but did not improve the antileukemic effect. The DAFT regimen was not associated with a higher incidence of GVHD or interstitial pneumonitis. This observation has led us to consider escalation of the dose of FTBI in our next clinical trial

  10. Relativistic total and differential cross section proton--proton electron--positron pair production calculation

    International Nuclear Information System (INIS)

    Rubinstein, J.E.

    1976-01-01

    Circle Feynman diagrams for a specific permutation of variables along with their corresponding algebraic expressions are presented to evaluate [H] 2 for proton-proton electron-positron pair production. A Monte Carlo integration technique is introduced and is used to set up the multiple integral expression for the total pair production cross section. The technique is first applied to the Compton scattering problem and then to an arbitrary multiple integral. The relativistic total cross section for proton-proton electron-positron pair production was calculated for eight different values of incident proton energy. A variety of differential cross sections were calculated for the above energies. Angular differential cross section distributions are presented for the electron, positron, and proton. Invariant mass differential cross section distributions are done both with and without the presence of [H] 2 . Both WGHT and log 10 (TOTAL) distributions were also obtained. The general behavioral trends of the total and differential cross sections for proton-proton electron-positron pair production are presented. The range of validity for this calculation is from 0 to about 200 MeV

  11. Total and ionization cross sections of electron scattering by fluorocarbons

    International Nuclear Information System (INIS)

    Antony, B K; Joshipura, K N; Mason, N J

    2005-01-01

    Electron impact total cross sections (50-2000 eV) and total ionization cross sections (threshold to 2000 eV) are calculated for typical plasma etching molecules CF 4 , C 2 F 4 , C 2 F 6 , C 3 F 8 and CF 3 I and the CF x (x 1-3) radicals. The total elastic and inelastic cross sections are determined in the spherical complex potential formalism. The sum of the two gives the total cross section and the total inelastic cross section is used to calculate the total ionization cross sections. The present total and ionization cross sections are found to be consistent with other theories and experimental measurements, where they exist. Our total cross section results for CF x (x = 1-3) radicals presented here are first estimates on these species

  12. Total-dielectric-function approach to electron and phonon response in solids

    International Nuclear Information System (INIS)

    Penn, D.R.; Lewis, S.P.; Cohen, M.L.

    1995-01-01

    The interaction between two test charges, the response of a solid to an external field, and the normal modes of the solid can be determined from a total dielectric function that includes both electronic and lattice polarizabilities as well as local-field effects. In this paper we examine the relationship between superconductivity and the stability of a solid and derive sum rules for the electronic part of the dielectric function. It is also shown that there are negative eigenvalues of the total static dielectric function, implying the possibility of an attractive interaction between test charges. An attractive interaction is required for superconductivity

  13. Ionization of molecules by electron impact: Differential and total cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Rezkallah, Z. [Laboratoire de Physique Quantique et Systemes Dynamiques, Departement de physique, Faculte des sciences, Universite Ferhat Abbas, Setif 19000 (Algeria); Houamer, S., E-mail: hosalim@yahoo.com [Laboratoire de Physique Quantique et Systemes Dynamiques, Departement de physique, Faculte des sciences, Universite Ferhat Abbas, Setif 19000 (Algeria); Dal Cappello, C. [Laboratoire de Physique Moleculaire et des Collisions, Universite Paul Verlaine-Metz, Institut de Physique, 1 Boulevard Arago, 57078 Metz Cedex 3 (France); Charpentier, I. [Laboratoire de Physique et Mecanique des Materiaux, Universite Paul Verlaine-Metz UMR 7554, ile du Saulcy, 57045 Metz Cedex 1 (France); Roy, A.C. [School of Mathematical Sciences, Ramakrishna Mission Vivekananda University, Belur Math 711202, West Bengal (India)

    2011-12-01

    The first Born approximation is applied to calculate differential and total ionization cross sections of a set of small molecules, namely, HF, H{sub 2}O, NH{sub 3} and CH{sub 4} by electron impact. The molecular targets are described by single center molecular orbitals consisting of linear combinations of atomic orbitals (MO-LCAO). First, we have considered electron momentum spectroscopy experiments to check the accuracy of the wave functions. The triply, doubly, singly differential and total cross sections are then evaluated in a systematic way for a variety of kinematics. The results are discussed and compared with experiments.

  14. A Triple Iron Triathlon Leads to a Decrease in Total Body Mass but Not to Dehydration

    Science.gov (United States)

    Knechtle, Beat; Knechtle, Patrizia; Rosemann, Thomas; Oliver, Senn

    2010-01-01

    A loss in total body mass during an ultraendurance performance is usually attributed to dehydration. We identified the changes in total body mass, fat mass, skeletal muscle mass, and selected markers of hydration status in 31 male nonprofessional ultratriathletes participating in a Triple Iron triathlon involving 11.4 km swimming, 540 km cycling…

  15. Kinetics of total body retention and clearance of xenon and krypton after inhalation

    International Nuclear Information System (INIS)

    Susskind, H.; Atkins, H.L.; Cohn, S.H.; Ellis, K.J.; Richards, P.

    1976-01-01

    The total body retention of Xe-127 and Kr-79 and their clearance rates following inhalation were measured in vivo. These data are useful for refined Xe-127 dosimetry calculations, to determine the potential radiation hazard of fission product Kr-85, and more generally to study the behavior of anesthetic gases. While data are available on the solubilities and partition coefficients of Xe and Kr in fat, blood, and other individual body constituents, few measurements of their retention and clearance from the entire body have been reported

  16. Total body topical 5-fluorouracil for extensive non-melanoma skin cancer

    NARCIS (Netherlands)

    van Ruth, Serge; Jansman, Frank G. A.; Sanders, Cornelis J.

    Background Topical 5-fluorouracil 5% cream is one of the treatment modalities for non-melanoma skin cancer (NMSC). There is a lack of suitable therapies to treat patients with extensive NMSC. In this paper we report two patients with extensive NMSC treated by total body application of topical

  17. Total body calcium by neutron activation analysis. Reference data for children

    International Nuclear Information System (INIS)

    Ellis, K.J.; Shypailo, R.J.

    2001-01-01

    There is a paucity of data on the chemical composition of the human body during growth. Total body calcium (TBCa) has been reported for only one male child, aged 41/2 yr. TBCa values for 25 children and 27 young women using in vivo neutron activation analysis have been obtained. TBCa results were lower than those reported for the one male cadaver, as well as the estimates derived for the 'Reference Man' model. It was concluded that the reference values for TBCa may need to be adjusted to appropriately describe skeletal mineralization of contemporary children. (author)

  18. Treatment of neuroblastoma. Role of total Body Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Dini, G; Perin, G P; Franzone, P; Corvo, R; Scarpati, D

    1986-01-01

    Advanced neuroblastoma, scarcely responsive to conventional therapies, can take advantage of high dose chemio-radiotherapic treatment followed by bone marrow transplant. Nineteen young patients underwent an ablative chemotherapy with high dose Vincristine and Melphalan plus Total Body Irradiation in Genoa, Italy; all of them underwent autologus bone marrow transplantation. Fourteen children were in complete remission (CR), 5 had residual disease. Thirteen are alive after a median of 7 months following transplant; 9 are in CR; 4 have disease; 1 died for toxicity; 5 for relapse. The results seem to suggest that ablative therapy should be given to patients in CR. Toxicity was not remarkable mainly as far as TBI is concerned.

  19. Comparison of total body water determinations in lactating women by anthropometry, water displacement, and deuterium isotope dilution

    International Nuclear Information System (INIS)

    Wong, W.; Butte, N.; Lee, L.; Garza, C.; Klein, P.

    1986-01-01

    To expand the limited data on the total body water in lactating women, the authors have determined total body water contents, in eight subjects from anthropometric measurements, water displacement, and isotope dilution of deuterium oxide. On the day of the study, their skinfold thicknesses were measured over the biceps and triceps muscles and at the suprailiac and subscapular areas. Their body densities were measured by water displacement. Deuterium oxide was administered orally at 100 mg/kg of body weight. One predose milk sample was collected from each subject. The milk samples were defatted by centrifugation and the milk water was reduced to hydrogen gas for hydrogen isotope ratio measurements by gas-isotope-ratio mass spectrometry. The results indicated that total body water in lactating women estimated from anthropometric measurements was 49.7 +/- 3.3% of body weight, by water displacement was 54.9 +/- 7.2%, and by isotope dilution was 50.8 +/- 3.7%

  20. ZZ DOSDAT-2, Gamma and Electron Dose Conversion Factor Data Library for Body Organs

    International Nuclear Information System (INIS)

    1983-01-01

    1 - Description of problem or function: Format: DOSDAT-R; Nuclides: gamma-ray and electron dose rates for whole-body and for various body organs (24) for air and water immersion and from ground-surface sources (approximately 500 radioactive nuclides). Origin: DLC-80/DRALIST library of radioactive decay data. The data are used to estimate the gamma-ray and electron dose rates for whole-body and for various body organs (24) for air and water immersion and from ground-surface sources. The data are given for approximately 500 radioactive nuclides. 2 - Method of solution: The data were computed by the CCC-400 DOSAFACTER II code from the DLC-80/DRALIST library of radioactive decay data for approximately 500 nuclides

  1. In vivo Prompt Gamma Neutron Activation Analysis Facility for Total Body Nitrogen and Cd

    International Nuclear Information System (INIS)

    Munive, Marco; Revilla, Angel; Solis, Jose L.

    2007-01-01

    A Prompt Gamma Neutron Activation Analysis (PGNAA) system has been designed and constructed to measure the total body nitrogen and Cd for in vivo studies. An aqueous solution of KNO 3 was used as phantom for system calibration. The facility has been used to monitor total body nitrogen (TBN) of mice and found that is related to their diet. Some mice swallowed diluted water with Cl 2 Cd, and the presence of Cd was detected in the animals. The minimum Cd concentration that the system can detect was 20 ppm

  2. Estimation of total body water by bioelectrical impedance analysis

    International Nuclear Information System (INIS)

    Kushner, R.F.; Schoeller, D.A.

    1986-01-01

    Total body water (TBW) measured by bioelectrical impedance analysis (BIA) was directly compared with deuterium-isotope dilution in a total of 58 subjects. First, sex-specific and group equations were developed by multiple regression analysis in (10 each) obese and nonobese men and women. Height/resistive impedance was the most significant variable used to predict deuterium-dilution space (D2O-TBW) and, combined with weight, yielded R = 0.99 and SE of estimate = 1.75 L. Equations predicted D2O-TBW equally well for obese and nonobese subjects. Second, the equations were prospectively tested in a heterogeneous group of 6 males and 12 females. Sex-specific equations predicted D2O-TBW with good correlation coefficients (0.96 and 0.93), total error (2.34 and 2.89 L), and a small difference between mean predicted and measured D2O-TBW (-1.4 +/- 2.05 and -0.48 +/- 2.83 L). BIA predicts D2O-TBW more accurately than weight, height, and/or age. A larger population is required to validate the applicability of our equations

  3. Analysis of Total Electron Content and Electron Density Profile during Different Geomagnetic Storms

    Science.gov (United States)

    Chapagain, N. P.; Rana, B.; Adhikari, B.

    2017-12-01

    Total Electron content (TEC) and electron density are the key parameters in the mitigation of ionospheric effects on radio communication system. Detail study of the TEC and electron density variations has been carried out during geomagnetic storms, with longitude and latitude, for four different locations: (13˚N -17˚N, 88˚E -98˚E), (30˚N-50˚N, 120˚W -95˚W), (29˚S-26˚S, 167˚W-163˚W,) and (60˚S-45˚S, 120˚W-105˚W) using the Gravity Recovery and Climate Experiment (GRACE) satellite observations. In order to find the geomagnetic activity, the solar wind parameters such as north-south component of inter planetary magnetic field (Bz), plasma drift velocity (Vsw), flow pressure (nPa), AE, Dst and Kp indices were obtained from Operating Mission as Nodes on the Internet (OMNI) web system. The data for geomagnetic indices have been correlated with the TEC and electron density for four different events of geomagnetic storms on 6 April 2008, 27 March 2008, 4 September 2008, and 11 October 2008. The result illustrates that the observed TEC and electron density profile significantly vary with longitudes and latitudes. This study illustrates that the values of TEC and the vertical electron density profile are influenced by the solar wind parameters associated with solar activities. The peak values of electron density and TEC increase as the geomagnetic storms become stronger. Similarly, the electron density profile varies with altitudes, which peaks around the altitude range of about 250- 350 km, depending on the strength of geomagnetic storms. The results clearly show that the peak electron density shifted to higher altitude (from about 250 km to 350 km) as the geomagnetic disturbances becomes stronger.

  4. Increases of equatorial total electron content (TEC) during magnetic storms

    International Nuclear Information System (INIS)

    Yeboah-Amankwah, D.

    1976-01-01

    This paper is a report on the analysis of equatorial electron content, TEC, during magnetic storms. Storms between 1969 and 1972 have been examined as part of an on-going study of TEC morphology during magnetically disturbed days. The published magnetic Ksup(p) indices and TEC data from the Legon abservatory have been employed. The general picture arising from the analysis is that the total electron content of the ionosphere is significantly enhanced during magnetic storms. (author)

  5. Inversion of the total cross sections for electron-molecule and electron-atom scattering

    International Nuclear Information System (INIS)

    Lun, D.R.; Amos, K.; Allen, L.J.

    1994-01-01

    Inverse scattering theory has been applied to construct the interaction potentials from total cross sections as a function of energy for electrons scattered off of atoms and molecules. The underlying potentials are assumed to be real and energy independent and are evaluated using the Eikonal approximation and with real phase shifts determined from the total cross sections. The inversion potentials have been determined using either a high energy limit approximation or by using a fixed energy inversion method at select energies. These procedures have been used to analyse e - - CH 4 , e - - SiH 4 , e - -Kr and e - -Xe scattering data in particular. 14 refs., 1 tabs., 3 figs

  6. Urea, creatinine, uric acid, and phosphate spaces and their relationship to total body water during chronic hemodialysis

    International Nuclear Information System (INIS)

    Ericsson, F.; Odar-Cederloef, I.E.; Eriksson, C.G.; Lindgren, S.; Kjellstrand, C.M.

    1988-01-01

    The authors determined total body water (TBW) with tritium in 11 patients on chronic hemodialysis and compared this space to that estimated by 60% of body weight, and removal spaces of urea, creatinine, uric acid, and phosphate (PO 4 ). The latter spaces were determined by dividing the total amount of substance (measured in total dialysate) by pre- minus post-dialysis concentrations. Body water X 0.6 was more than 10% less than the tritium space, and showed a maximal variation of 10 liters, or 24%. The removal space of urea was 80% of the tritium space, but correlated closely with it. The difference between total body water and urea removal space was variable and dependent on fluid excess (edema) in the patients. Creatinine, uric acid, and phosphate removal spaces were highly variable and not correlated to total body water. The authors suggest that actual measured TBW should be used, rather than estimations using BW X 0.6, for V in K X T/V, where K = clearance, T = duration of dialysis, and V = the removal space of urea. Furthermore, one may need to introduce a correction factor for urea removal space over TBW in the equation to allow better quantification of dialysis in edematous patients and during very fast dialyses

  7. Late effects on gonadal function of cyclophosphamide, total-body irradiation, and marrow transplantation

    International Nuclear Information System (INIS)

    Sanders, J.E.; Buckner, C.D.; Leonard, J.M.; Sullivan, K.M.; Witherspoon, R.P.; Deeg, H.J.; Storb, R.; Thomas, E.D.

    1983-01-01

    One hundred thirty-seven patients had gonadal function evaluated 1-11 years after marrow transplantation. All 15 women less than age 26 and three of nine older than age 26 who were treated with 200 mg/kg cyclophosphamide recovered normal gonadotropin levels and menstruation. Five have had five pregnancies resulting in three live births, one spontaneous abortion, and one elective abortion. Three of 38 women who were prepared with 120 mg/kg cyclophosphamide and 920-1200 rad total-body irradiation had normal gonadotropin levels and menstruation. Two had pregnancies resulting in one spontaneous and one elective abortion. Of 31 men prepared with 200 mg/kg cyclophosphamide, 30 had normal luteinizing hormone levels, 20 had normal follicle-stimulating hormone levels, and 10 of 15 had spermatogenesis. Four have fathered five normal children. Thirty-six of 41 men prepared with 120 mg/kg cyclophosphamide and 920-1750 rad total-body irradiation had normal luteinizing hormone levels, ten had normal follicle-stimulating hormone levels, and 2 of 32 studied had spermatogenesis. One has fathered two normal children. It was concluded that cyclophosphamide does not prevent return of normal gonadal function in younger women and in most men. Total-body irradiation prevents return of normal gonadal function in the majority of patients

  8. Optimum combination of targeted 131I and total body irradiation for treatment of disseminated cancer

    International Nuclear Information System (INIS)

    Amin, Amin E.; Wheldon, Tom E.; O'Donoghue, Joseph A.; Gaze, Mark N.; Barrett, Ann

    1995-01-01

    Purpose: Radiobiological modeling was used to explore optimum combination strategies for treatment of disseminated malignancies of differing radiosensitivity and differing patterns of metastatic spread. The purpose of the study was to derive robust conclusions about the design of combination strategies that incorporate a targeting component. Preliminary clinical experience of a neuroblastoma treatment strategy, which is based upon general principles obtained from modelling, is briefly described. Methods and Materials: The radiobiological analysis was based on an extended (dose-rate dependent) formulation of the linear quadratic model. Radiation dose and dose rate for targeted irradiation of tumors of differing size was in part based on microdosimetric considerations. The analysis was applied to several tumor types with postulated differences in the pattern of metastatic spread, represented by the steepness of the slope of the relationship between numbers of tumors present and tumor diameter. The clinical pilot study entailed the treatment of five children with advanced neuroblastoma using a combination of 131 I metaiodobenzylguanidine (mIBG) and total body irradiation followed by bone marrow rescue. Results: The theoretical analysis shows that both intrinsic radiosensitivity and pattern of metastatic spread can influence the composition of the ideal optimum combination strategy. High intrinsic radiosensitivity generally favors a high proportion of targeting component in the combination treatment, while a strong tendency to micrometastatic spread favors a major contribution by total body irradiation. The neuroblastoma patients were treated using a combination regimen with an initially low targeting component (2 Gy whole body dose from targeting component plus 12 Gy from total body irradiation). The treatment was tolerable and resulted in remissions in excess of 9 months in each of these advanced neuroblastoma patients. Conclusions: Radiobiological analysis, which

  9. The use of bioelectrical impedance analysis to estimate total body water in young children with cerebral palsy.

    Science.gov (United States)

    Bell, Kristie L; Boyd, Roslyn N; Walker, Jacqueline L; Stevenson, Richard D; Davies, Peter S W

    2013-08-01

    Body composition assessment is an essential component of nutritional evaluation in children with cerebral palsy. This study aimed to validate bioelectrical impedance to estimate total body water in young children with cerebral palsy and determine best electrode placement in unilateral impairment. 55 young children with cerebral palsy across all functional ability levels were included. Height/length was measured or estimated from knee height. Total body water was estimated using a Bodystat 1500MDD and three equations, and measured using the gold standard, deuterium dilution technique. Comparisons were made using Bland Altman analysis. For children with bilateral impairment, the Fjeld equation estimated total body water with the least bias (limits of agreement): 0.0 L (-1.4 L to 1.5 L); the Pencharz equation produced the greatest: 2.7 L (0.6 L-4.8 L). For children with unilateral impairment, differences between measured and estimated total body water were lowest on the unimpaired side using the Fjeld equation 0.1 L (-1.5 L to 1.6 L)) and greatest for the Pencharz equation. The ability of bioelectrical impedance to estimate total body water depends on the equation chosen. The Fjeld equation was the most accurate for the group, however, individual results varied by up to 18%. A population specific equation was developed and may enhance the accuracy of estimates. Australian New Zealand Clinical Trials Registry (ANZCTR) number: ACTRN12611000616976. Copyright © 2012 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  10. Total body irradiation

    International Nuclear Information System (INIS)

    Barrett, A.

    1988-01-01

    This paper describes body irradiation (TBI) being used increasingly as consolidation treatment in the management of leukaemia, lymphoma and various childhood tumours with the aim of sterilizing any malignant cells or micrometastases. Systemic radiotherapy as an adjunct to chemotherapy offers several possible benefits. There are no sanctuary sites for TBI; some neoplastic cells are very radiosensitive, and resistance to radiation appears to develop less readily than to drugs. Cross-resistance between chemotherapy and radiotherapy does not seem to be common and although plateau effects may be seen with chemotherapy there is a linear dose-response curve for clonogenic cell kill with radiation

  11. Total skin electron therapy as treatment for epitheliotropic lymphoma in a dog.

    Science.gov (United States)

    Santoro, Domenico; Kubicek, Lyndsay; Lu, Bo; Craft, William; Conway, Julia

    2017-04-01

    Mycosis fungoides (MF) is an uncommon cutaneous neoplasm in dogs. Treatment options are limited. Total skin electron therapy (TSET) has been suggested as a possible therapy for canine MF. To describe the use of TSET as palliative treatment for MF in a dog. An adult dog, previously diagnosed with nonepidermolytic ichthyosis, was presented with generalized erythroderma, alopecia and erosions. Histopathology revealed a densely cellular, well-demarcated, unencapsulated infiltrate extending from the epidermis to the mid-dermis compatible with MF. The infiltrate exhibited epitheliotropism multifocally for the epidermis, infundibula and adnexa. Due to a lack of response to chemotherapy, TSET was elected. Six megavoltage electrons were delivered using a 21EX Varian linear accelerator. A dose of 6 Gy was delivered to the skin surface and a 100 cm skin to surface distance was used for dog setup. The treatment time for the cranial half treatment was 3 h. The treatment was divided in two sessions (cranial and caudal halves of the body) 15 days apart. Clinical and histopathological complete remission was achieved and the dog was kept in remission with no additional treatments for 19 months before relapse and development of Sézary syndrome. To the best of the authors' knowledge, this is the first case reporting the use of TSET for medically refractory canine MF with post treatment follow-up. This case suggests that the use of TSET may be an effective palliative treatment for canine MF. © 2017 ESVD and ACVD.

  12. On the Fokker-Planck theory of electron three-body recombination

    International Nuclear Information System (INIS)

    Sayasov, Yu. S.

    1977-01-01

    The Fokker-Planck theory of electron three-body recombination based on the concept of electron diffusion along the energy scale in the excited hydrogen-like atoms formed in the recombining plasmas, is extended in several respects. 1) An universal formula for population distribution of the excited atoms in strongly ionized plasmas was found under a sole assumption, that the cross-sections for the inelastic atom-electron collisions are governed by the classical impulse approximation. 2) A general Fokker-Planck theory of the recombination in a slightly ionized, two-temperature plasmas was formulated. The recombination coefficients for such plasmas were shown to possess some peculiar properties in case the electronic temperature differs appreciable from the atomic one. A few limitations of the existing schemas for calculation of the recombination kinetics are briefly discussed. (orig.) [de

  13. Are trends in total electron content (TEC) really positive?

    Czech Academy of Sciences Publication Activity Database

    Laštovička, Jan

    2013-01-01

    Roč. 118, č. 6 (2013), s. 3831-3835 ISSN 2169-9380 R&D Projects: GA ČR GAP209/10/1792 Institutional support: RVO:68378289 Keywords : Long-term trends * total electron content Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 3.440, year: 2013 http://onlinelibrary.wiley.com/doi/10.1002/jgra.50261/abstract

  14. Evaluation of nuclear magnetic resonance spectroscopy for determination of deuterium abundance in body fluids: application to measurement of total-body water in human infants

    International Nuclear Information System (INIS)

    Rebouche, C.J.; Pearson, G.A.; Serfass, R.E.; Roth, C.W.; Finley, J.W.

    1987-01-01

    Nuclear magnetic resonance (NMR) spectroscopy was used to quantitate abundance of 2H in body water of human infants. This method provides precise measurement of total-body water without the extensive sample preparation requirements of previously described methods for determination of 2H content in body fluids. 2H2O (1 g/kg body weight) was administered to infants and saliva and urine were collected for up to 5 h. An internal standard was added directly to the fluid specimen and 2H enrichment in water was measured by NMR spectroscopy. Working range of deuterium abundance was 0.04-0.32 atom %. Coefficients of variation for saliva samples at 0.20 atom % 2H was 1.97%. 2H content in urine and saliva water reached a plateau by 4 h after administration, and amounts in the two fluids were virtually identical. Mean total-body water determination for six infants was 58.3 +/- 5.8% of body weight (range 53-66%)

  15. Study of total ionization dose effects in electronic devices

    International Nuclear Information System (INIS)

    Nidhin, T.S.; Bhattacharyya, Anindya; Gour, Aditya; Behera, R.P.; Jayanthi, T.

    2018-01-01

    Radiation effects in electronic devices are a major challenge in the dependable application developments of nuclear power plant instrumentation and control systems. The main radiation effects are total ionization dose (TID) effects, displacement damage dose (DDD) effects and single event effects (SEE). In this study, we are concentrating on TID effects in electronic devices. The focus of the study is mainly on SRAM based field programmable gate arrays (FPGA) along with that the devices of our interest are voltage regulators, flash memory and optocoupler. The experiments are conducted by exposing the devices to gamma radiation in power off condition and the degradation in the performances are analysed

  16. Modeling of the Ionospheric Scintillation and Total Electron Content Observations during the 21 August 2017 Total Solar Eclipse

    Science.gov (United States)

    Datta-Barua, S.; Gachancipa, J. N.; Deshpande, K.; Herrera, J. A.; Lehmacher, G. A.; Su, Y.; Gyuk, G.; Bust, G. S.; Hampton, D. L.

    2017-12-01

    High concentration of free electrons in the ionosphere can cause fluctuations in incoming electromagnetic waves, such as those from the different Global Navigation Satellite Systems (GNSS). The behavior of the ionosphere depends on time and location, and it is highly influenced by solar activity. The purpose of this study is to determine the impact of a total solar eclipse on the local ionosphere in terms of ionospheric scintillations, and on the global ionosphere in terms of TEC (Total Electron Content). The studied eclipse occurred on 21 August 2017 across the continental United States. During the eclipse, we expected to see a decrease in the scintillation strength, as well as in the TEC values. As a broader impact part of our recently funded NSF proposal, we temporarily deployed two GNSS receivers on the eclipse's totality path. One GNSS receiver was placed in Clemson, SC. This is a multi-frequency GNSS receiver (NovAtel GPStation-6) capable of measuring high and low rate scintillation data as well as TEC values from four different GNSS systems. We had the receiver operating before, during, and after the solar eclipse to enable the comparison between eclipse and non-eclipse periods. A twin receiver collected data at Daytona Beach, FL during the same time, where an 85% partial solar eclipse was observed. Additionally, we set up a ground receiver onsite in the path of totality in Perryville, Missouri, from which the Adler Planetarium of Chicago launched a high-altitude balloon to capture a 360-degree video of the eclipse from the stratosphere. By analyzing the collected data, this study looks at the effects of partial and total solar eclipse periods on high rate GNSS scintillation data at mid-latitudes, which had not been explored in detail. This study also explores the impact of solar eclipses on signals from different satellite constellations (GPS, GLONASS, and Galileo). Throughout the eclipse, the scintillation values did not appear to have dramatic changes

  17. Dose equivalent distributions in the AAEC total body nitrogen facility

    International Nuclear Information System (INIS)

    Allen, B.J.; Bailey, G.M.; McGregor, B.J.

    1985-01-01

    The incident neutron dose equivalent in the AAEC total body nitrogen facility is measured by a calibrated remmeter. Dose equivalent rates and distributions are calculated by Monte Carlo techniques which take account of the secondary neutron flux from the collimator. Experiment and calculation are found to be in satisfactory agreement. The effective dose equivalent per exposure is determined by weighting organ doses, and the potential detriment per exposure is calculated from ICRP risk factors

  18. Calculation of total and ionization cross sections for electron scattering by primary benzene compounds

    Science.gov (United States)

    Singh, Suvam; Naghma, Rahla; Kaur, Jaspreet; Antony, Bobby

    2016-07-01

    The total and ionization cross sections for electron scattering by benzene, halobenzenes, toluene, aniline, and phenol are reported over a wide energy domain. The multi-scattering centre spherical complex optical potential method has been employed to find the total elastic and inelastic cross sections. The total ionization cross section is estimated from total inelastic cross section using the complex scattering potential-ionization contribution method. In the present article, the first theoretical calculations for electron impact total and ionization cross section have been performed for most of the targets having numerous practical applications. A reasonable agreement is obtained compared to existing experimental observations for all the targets reported here, especially for the total cross section.

  19. Calculation of total and ionization cross sections for electron scattering by primary benzene compounds

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Suvam; Naghma, Rahla; Kaur, Jaspreet; Antony, Bobby, E-mail: bka.ism@gmail.com [Atomic and Molecular Physics Lab, Department of Applied Physics, Indian School of Mines, Dhanbad (India)

    2016-07-21

    The total and ionization cross sections for electron scattering by benzene, halobenzenes, toluene, aniline, and phenol are reported over a wide energy domain. The multi-scattering centre spherical complex optical potential method has been employed to find the total elastic and inelastic cross sections. The total ionization cross section is estimated from total inelastic cross section using the complex scattering potential-ionization contribution method. In the present article, the first theoretical calculations for electron impact total and ionization cross section have been performed for most of the targets having numerous practical applications. A reasonable agreement is obtained compared to existing experimental observations for all the targets reported here, especially for the total cross section.

  20. Total Body Capacitance for Estimating Human Basal Metabolic Rate in an Egyptian Population

    Science.gov (United States)

    M. Abdel-Mageed, Samir; I. Mohamed, Ehab

    2016-01-01

    Determining basal metabolic rate (BMR) is important for estimating total energy needs in the human being yet, concerns have been raised regarding the suitability of sex-specific equations based on age and weight for its calculation on an individual or population basis. It has been shown that body cell mass (BCM) is the body compartment responsible for BMR. The objectives of this study were to investigate the relationship between total body capacitance (TBC), which is considered as an expression for BCM, and BMR and to develop a formula for calculating BMR in comparison with widely used equations. Fifty healthy nonsmoking male volunteers [mean age (± SD): 24.93 ± 4.15 year and body mass index (BMI): 25.63 ± 3.59 kg/m2] and an equal number of healthy nonsmoking females matched for age and BMI were recruited for the study. TBC and BMR were measured for all participants using octopolar bioelectric impedance analysis and indirect calorimetry techniques, respectively. A significant regressing equation based on the covariates: sex, weight, and TBC for estimating BMR was derived (R=0.96, SEE=48.59 kcal, and P<0.0001), which will be useful for nutritional and health status assessment for both individuals and populations. PMID:27127453

  1. Effect of BCNU combined with total body irradiation or cyclophosphamide on survival of dogs after autologous marrow grafts

    International Nuclear Information System (INIS)

    Paterson, A.H.G.; English, D.

    1979-01-01

    Dogs were treated with either: (1) 750 rad total body irradiation; (2) BCNU 2 or 4 mg/kg IV 48 hours prior to 750 rad total body irradiation; or (3) BCNU 4 mg/kg IV plus cyclophosphamide 30 mg/kg IV. Results showed that of 11 dogs who received 750 rad total body irradiation and did not receive cryopreserved autologous bone marrow cells, none survived, compared to an 88% survival (31 of 35 dogs) after 750 rad total body irradiation if the dogs received stored autologous bone marrow cells. However, when the dogs were treated with BCNU 2 or 4 mg/kg prior to 750 rad total body irradiation the survival rate, despite infusion of autologous bone marrow cells, dropped to 25% (3 of 12 dogs) for BCNU 2 mg/kg, and 17% (2 of 12 dogs) for BCNU 4 mg/kg. This effect did not seem to be due to direct serum inhibition of hemopoietic cell proliferation since serum obtained at various intervals after BCNU administrations failed to inhibit CFU growth in vitro. The dogs died from hemorrhage and infection; at autopsy there was hemorrhagic pneumonitis and intestinal ulcerations with petechial hemorrhages, suggesting that the combination of BCNU and total body irradiation may have synergistic toxicity on the canine gastro-intestinal tract. When BCNU was combined with cyclophosphamide, reversal of marrow toxicity occurred in 54% (6 of 11 dogs) with stored autologous bone marrow cells compared to no survival (0 of 8 dogs) with stored autologous bone marrow cells. Thus while autologous bone marrow grafts are useful for reversal of marrow toxicity due to many therapeutic protocols, such grafts alone may not provide protection against toxicity due to the combination of high dosage BCNU and total body irradiation

  2. Use of an electron reflector to improve dose uniformity at the vertex during total skin electron therapy

    International Nuclear Information System (INIS)

    Peters, V.G.

    2000-01-01

    Purpose: The vertex of the scalp is always tangentially irradiated during total skin electron therapy (TSET). This study was conducted to determine the dose distribution at the vertex for a commonly used irradiation technique and to evaluate the use of an electron reflector, positioned above the head, as a means of improving the dose uniformity. Methods and Materials: Phantoms, simulating the head of a patient, were irradiated using our standard procedure for TSET. The technique is a six-field irradiation using dual angled electron beams at a treatment distance of 3.6 meters. Vertex dosimetry was performed using ionization methods and film. Measurements were made for an unmodified 6 MeV electron beam and for a 4 MeV beam obtained by placing an acrylic scattering plate in the beam line. Studies were performed to examine the effect of electron scattering on vertex dose when a lead reflector, 50 x 50 cm in area, was positioned above the phantom. Results: The surface dose at the vertex, in the absence of the reflector, was found to be less than 40% of the prescribed skin dose. Use of the lead reflector increased this value to 73% for the 6 MeV beam and 99% for the degraded 4 MeV beam. Significant improvements in depth dose were also observed. The dose enhancement is not strongly dependent on reflector distance or angulation since the reflector acts as a large source of broadly scattered electrons. Conclusion: The vertex may be significantly underdosed using standard techniques for total skin electron therapy. Use of an electron reflector improves the dose uniformity at the vertex and may reduce or eliminate the need for supplemental irradiation

  3. The relationship of total body composition with bone mineral density in postmenopausal women with type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Vadim Valer'evich Klimontov

    2015-03-01

    Full Text Available AimTo determine the relationship between bone mineral density (BMD and total body composition in postmenopausal women with type 2 diabetes.Materials and MethodsThe study included 78 women, from 50 to 70 years of age (median 63 years. Twenty women had normal body mass index (BMI, 29 ones were overweight and 29 had obesity. The body composition and BMD was studied by dual-energy X-ray absorptiometry.ResultsWomen with normal BMD had higher BMI, total and truncal fat mass, as well lean mass as compared to women with osteoporosis and osteopenia (all p <0.05. Patients with osteoporosis had a lower fat mass at the hips, compared with those with normal BMD. Total and truncal fat mass, as well as lean mass were positively correlated with BMD in the lumbar spine and proximal femur, femoral neck and radius. In multivariate regression analysis fat mass was an independent predictor for total BMD, after adjusting for age, BMI, duration of menopause, HbA1c, glomerular filtration rate and other total body composition parameters.ConclusionsIn postmenopausal type 2 diabetic women BMI and fat mass is associated positively with BMD.

  4. SU-F-T-83: Infant Total Skin Electron Therapy Using Five Fields Technique

    International Nuclear Information System (INIS)

    Saleh, H; Howlin, T; Massey, V

    2016-01-01

    Purpose: We were presented with a 9 month old boy with Relapsed Acute Myeloid Leukemia (AML) involving the skin. The plan was to treat the entire skin using 6 MeV electrons with the infant under complete anesthesia. The purpose of this work is to commission the 6 MeV electron beam and to develop a technique that can be used to deliver total skin dose to infants with minimal patient immobilization. Methods: A baby mannequin phantom that mimics the child’s length was used to determine the best technique to treat the infant. The 76 cm long phantom was placed on the floor. The phantom was placed in four unique immobilization devices to simulate four different treatment positions (anterior, posterior, left lateral and right lateral). Radiochromic films were used to determine beam profile in both axial and radial directions, and percent depth dose (PDD). Absolute calibration of the machine output at 214 cm distance was measured using an Exradin A11 parallel-plate ion chamber. A 1.0 cm plexiglass scatter plate was inserted in the collimator. Mosfet dosimeters were used for dose verification for phantom and and patient. Results: At 214 cm source to surface distance (SSD) using gantry angle of + 20o from vertical beam flatness is + 10% in the radial direction over a region of 70 cm and + 4% in the axial direction over 60 cm. A five field arrangement was determined to optimally deliver the desired dose with > 90% uniformity. The fifth field was used to boost the head vertex. Conclusion: It is possible to treat sedated infants with total skin dose using five positions. Four positions were enough to cover the body and the fifth position boosts the vertex of the head. All fractions can be reproduced accurately daily because of the patient’s stable immobilization.

  5. SU-F-T-83: Infant Total Skin Electron Therapy Using Five Fields Technique

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, H; Howlin, T; Massey, V [University of Kansas Hospital, Overland Park, KS (United States)

    2016-06-15

    Purpose: We were presented with a 9 month old boy with Relapsed Acute Myeloid Leukemia (AML) involving the skin. The plan was to treat the entire skin using 6 MeV electrons with the infant under complete anesthesia. The purpose of this work is to commission the 6 MeV electron beam and to develop a technique that can be used to deliver total skin dose to infants with minimal patient immobilization. Methods: A baby mannequin phantom that mimics the child’s length was used to determine the best technique to treat the infant. The 76 cm long phantom was placed on the floor. The phantom was placed in four unique immobilization devices to simulate four different treatment positions (anterior, posterior, left lateral and right lateral). Radiochromic films were used to determine beam profile in both axial and radial directions, and percent depth dose (PDD). Absolute calibration of the machine output at 214 cm distance was measured using an Exradin A11 parallel-plate ion chamber. A 1.0 cm plexiglass scatter plate was inserted in the collimator. Mosfet dosimeters were used for dose verification for phantom and and patient. Results: At 214 cm source to surface distance (SSD) using gantry angle of + 20o from vertical beam flatness is + 10% in the radial direction over a region of 70 cm and + 4% in the axial direction over 60 cm. A five field arrangement was determined to optimally deliver the desired dose with > 90% uniformity. The fifth field was used to boost the head vertex. Conclusion: It is possible to treat sedated infants with total skin dose using five positions. Four positions were enough to cover the body and the fifth position boosts the vertex of the head. All fractions can be reproduced accurately daily because of the patient’s stable immobilization.

  6. Stakeout electronic total station construction layout boring of the experience and precision

    International Nuclear Information System (INIS)

    Xu Zhiqiang

    2012-01-01

    Electronic total station can simultaneously measure angle and distance, together with the appropriate calculation methods and operating skills, able to efficiently complete the survey work, this paper based on practical experience, theoretical analysis, based on total station introduced in setting out a few boring in the skills and the measurement of total station in the construction layout for accuracy. (authors)

  7. Measurement of total body calcium in osteoporotic patients treated with salmon calcitonin

    International Nuclear Information System (INIS)

    Zanzi, I.; Thompson, K.; Cohn, S.H.

    1981-01-01

    In the past, the evaluation of therapies for osteoporosis has been limited by the lack of a suitable quantitative end point. The introduction of the technique of in vivo total body neutron activation analysis (TBNAA) has made possible the precise and accurate measurement of total body calcium (TBCa). Since almost 99 percent of TBCa is in the skeleton, TBNAA gives a direct measurement of skeletal mass. Thus, changes in skeletal mass serve as an objective criterion in the evaluation of the efficacy of the therapy in osteoporosis. Studies performed at Brookhaven National Laboratory and elsewhere have reported the use of calcitonin (CT) in the treatment of primary osteoporosis and related conditions in a limited number of patients. The physiological effects of CT as an inhibitor of bone resorption has been the rationale of its use. The results of a randomized, controlled, 2 year therapeutical trial of CT in a group of postmenopausal osteoporotic women are presented in this report

  8. Abdominal Obesity and their association with Total Body: Fat Distribution and Composition. Case of Algerian Teenager Male high school students

    Directory of Open Access Journals (Sweden)

    Mohammed Zerf

    2017-06-01

    Full Text Available Purpose: Our aim attempted to esteem the impact of abdominal fat on body fat distribution or composition related to total body fat as recommended weight loss among High School Students. Material: For the proposed, 100 male students from the Algerian high school Education Sector's mandate Sidi Bel Abbes, participate in the present study. Their average age 16±1.52 years, distributed into homogeneous groups, according to their body fat percent categories. Examined by saving tests (Body Fat Percentage (BFP - Abdominal circumference (WC - Body mass index (BMI. Results: Based on the test data and the analysis statistics applied, we confirm: a Abdominal obesity is excess body gain correlate with total fat BMI. It highly affected body composition reported as additional fat for overweight in compare with acceptable according to Ideal BFP categories. b Abdominal obesity is an amount deep fat correlates to total BFP. It higher influenced the distribution of total body fat reported as additional excess fat among overweight category compared to the acceptable group. c Waist circumference (WC is the leading marker of abdominal fat deposits located in the central region of the body. While the combination of body mass index (BMI and waist circumference (WC, reflects the combined effects of body build (fat or fatness in individuals at higher risk of excessive body fat. Conclusions: founded on the differences acquired by the research team. We highlight that abdominal obesity is strongly connected to larger WC relate to total body gain located as excess inordinate fatness BMI or fat distribution BFP among our overall sample. Evidence, which guides us to recommend our adolescent students to intensification their hours of sports practice, in order to avoid the consequences of abdominal obesity gain. Announced in the present study as excess abdominal adiposity more metabolically active. Requiring the control of body weight loss (BFP or BMI strongly correlates to

  9. Skeletal and total body volumes of human fetuses: assessment of reference data by spiral CT

    International Nuclear Information System (INIS)

    Braillon, Pierre M.; Buenerd, Annie; Bouvier, Raymonde; Lapillonne, Alexandre

    2002-01-01

    Objective: To define reference data for skeletal and total body volumes of normal human fetuses. Materials and methods: Spiral CT was used to assess the skeletal and total body volumes of 31 normal human stillborn infants with gestational age (GA) and body weight (BW) ranging from 14 to 41.5 weeks and 22 to 3,760 g, respectively. CT scans (slice thickness 2.7 mm, pitch 0.7) were performed within the first 24 h after delivery. Precise bone and soft-tissue windows were defined from analysis of the density along the diaphysis of the fetal long bones and from the measurement of a phantom that mimics soft tissues. Lengths and volumes were obtained from 3D reconstructions. The femur lengths measured from CT images (FLct) were compared with those provided by US studies (FLus). Results: Significant correlations (r>0.9) were found between BW, measured volumes of the entire skeleton or head, long-bone lengths, biparietal diameter and GA. Strong linear correlations (r>0.98) were observed between FLct and FLus. Conclusions: Skeletal and total body volume values obtained using spiral CT were significantly correlated with fetal biometric measurements. These data could complement those obtained in obstetric investigations with US. (orig.)

  10. Bioimpedance index for measurement of total body water in severely malnourished children

    DEFF Research Database (Denmark)

    Girma, Tsinuel; Kæstel, Pernille; Workeneh, Netsanet

    2016-01-01

    BACKGROUND & OBJECTIVES: Restoration of body composition indicates successful management of severe acute malnutrition (SAM). Bioimpedance (BI) index (height(2)/resistance) is used to predict total body water (TBW) but its performance in SAM, especially with oedema, requires further investigation....... SUBJECTS/METHODS: Children with SAM (mid-arm circumference ...Hzs. Pre- and post-deuterium dose saliva samples were analysed using isotope-ratio mass spectrometry. TBW was regressed on H(2)/Z. Xc and R were height (H)-indexed, and Xc/H plotted against R/H. RESULTS: Thirty five children (16 non-oedematous and 19 oedematous) with median (interquartile range) age of 42...

  11. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    International Nuclear Information System (INIS)

    Karakas, Hakki Muammer; Celbis, Osman; Harma, Ahmet; Alicioglu, Banu

    2011-01-01

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 ± 14.9 years) and 43 women (41.1 ± 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 ± 12.6 mm (77-138 mm) in men and 104.7 ± 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  12. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    Energy Technology Data Exchange (ETDEWEB)

    Karakas, Hakki Muammer [Inonu University Medical Faculty, Turgut Ozal Medical Center, Department of Radiology, Malatya (Turkey); Celbis, Osman [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Forensic Medicine, Malatya (Turkey); Harma, Ahmet [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Orthopaedics and Traumatology, Malatya (Turkey); Alicioglu, Banu [Trakya University Medical Faculty, Department of Radiology, Edirne (Turkey); Trakya University Health Sciences Institute, Department of Anatomy, Edirne (Turkey)

    2011-05-15

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 {+-} 14.9 years) and 43 women (41.1 {+-} 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 {+-} 12.6 mm (77-138 mm) in men and 104.7 {+-} 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  13. SU-E-T-540: Volumetric Modulated Total Body Irradiation Using a Rotational Lazy Susan-Like Immobilization System

    International Nuclear Information System (INIS)

    Gu, X; Hrycushko, B; Lee, H; Lamphier, R; Jiang, S; Abdulrahman, R; Timmerman, R

    2014-01-01

    Purpose: Traditional extended SSD total body irradiation (TBI) techniques can be problematic in terms of patient comfort and/or dose uniformity. This work aims to develop a comfortable TBI technique that achieves a uniform dose distribution to the total body while reducing the dose to organs at risk for complications. Methods: To maximize patient comfort, a lazy Susan-like couch top immobilization system which rotates about a pivot point was developed. During CT simulation, a patient is immobilized by a Vac-Lok bag within the body frame. The patient is scanned head-first and then feet-first following 180° rotation of the frame. The two scans are imported into the Pinnacle treatment planning system and concatenated to give a full-body CT dataset. Treatment planning matches multiple isocenter volumetric modulated arc (VMAT) fields of the upper body and multiple isocenter parallel-opposed fields of the lower body. VMAT fields of the torso are optimized to satisfy lung dose constraints while achieving a therapeutic dose to the torso. The multiple isocenter VMAT fields are delivered with an indexed couch, followed by body frame rotation about the pivot point to treat the lower body isocenters. The treatment workflow was simulated with a Rando phantom, and the plan was mapped to a solid water slab phantom for point- and film-dose measurements at multiple locations. Results: The treatment plan of 12Gy over 8 fractions achieved 80.2% coverage of the total body volume within ±10% of the prescription dose. The mean lung dose was 8.1 Gy. All ion chamber measurements were within ±1.7% compared to the calculated point doses. All relative film dosimetry showed at least a 98.0% gamma passing rate using a 3mm/3% passing criteria. Conclusion: The proposed patient comfort-oriented TBI technique provides for a uniform dose distribution within the total body while reducing the dose to the lungs

  14. Quantitation of the degree of osteoporosis by measure of total-body calcium employing neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Zanzi, I.; Vaswani, A.; Wallach, S.; Aloia, J.; Ellis, K.J.

    1975-01-01

    Two techniques for measuring the amount of Ca in the total skeleton were employed: total-body neutron activation analysis (TBNAA) and the determination of the mineral content of a bone of the appendicular skeleton (absorptiometric measurement of the radius, BMC). (U.S.)

  15. Effects of Zinc Compound on Body Weight and Recovery of Bone Marrow in Mice Treated with Total Body Irradiation

    Directory of Open Access Journals (Sweden)

    Ming-Yii Huang

    2007-09-01

    Full Text Available This study aimed to investigate if zinc compound would have effects on body weight loss and bone marrow suppression induced by total body irradiation (TBI. ICR mice were divided randomly into two groups and treated with test or control compounds. The test compound contained zinc (amino acid chelated with bovine prostate extract, and the control was reverse osmosis pure water (RO water. One week after receiving the treatment, mice were unirradiated, or irradiated with 6 or 3 Gy by 6MV photon beams to the total body. Body weight changes were examined at regular intervals. Three and 5 weeks after the radiation, animals were sacrificed to examine the histologic changes in the bone marrow. Lower body weight in the period of 1-5 weeks after radiation and poor survival rate were found after the 6 Gy TBI, as compared with the 3 Gy groups. The median survival time after 6 Gy and 3 Gy TBI for mice given the test compound were 26 and 76 days, respectively, and the corresponding figures were 14 and 70 days, respectively, for mice given the control compound (p < 0.00001. With zinc supplement, the mean body weight in mice which received the same dose of radiation was 7-8 g heavier than in the water-supplement groups during the second and third weeks (p < 0.05. Hence, there was no statistically significant difference in survival rate between zinc and water supplement in mice given the same dose of irradiation. Histopathologically there was less recovery of bone marrow cells in the 6Gy groups compared with the 3Gy groups. In the 3 Gy water-supplement group, the nucleated cells and megakaryocytes were recovered in the fifth week when recovery was still not seen in the 6Gy group. With zinc supplement, these cells were recovered in the third week. In this study, we found that zinc is beneficial to body weight in mice treated with TBI. Histologic examination of bone marrow showed better recovery of bone marrow cells in groups of mice fed with zinc. This study

  16. Hepatic, renal, and total body galactose elimination in the pig

    DEFF Research Database (Denmark)

    Winkler, K; Henriksen, Jens Henrik Sahl; Tygstrup, N

    1993-01-01

    Galactose elimination capacity is used as a quantitative measure of liver function on the assumption that galactose elimination outside the liver is negligible or easily corrected for. The relationship between hepatic and extrahepatic removal of galactose was studied in anesthetized pigs during...... reabsorption (Tm 178 +/- 3.0 mumol/min, Km 3.8 +/- 0.9 mmol/l, n = 20). Metabolic conversion of galactose in the kidney was not demonstrable. At all concentrations studied (0.4-5.8 mmol/l), total galactose elimination from the body exceeded the sum of hepatic and renal elimination by approximately 100 mumol....../min, independent of the concentration. At blood concentrations usually used for clinical estimation of the galactose elimination capacity (approximately 4 mmol/l), hepatic removal in the pig accounted for 55% and renal removal for 30% of total removal; 15% of removal occurred in other organs. We conclude...

  17. The relationship of total body composition with bone mineral density in postmenopausal women with type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Vadim Valer'evich Klimontov

    2015-03-01

    Full Text Available Aim. To determine the relationship between bone mineral density (BMD and total body composition in postmenopausal women with type 2 diabetes. Materials and Methods. The study included 78 women, from 50 to 70 years of age (median 63 years. Twenty women had normal body mass index (BMI, 29 ones were overweight and 29 had obesity. The body composition and BMD was studied by dual-energy X-ray absorptiometry. Results. Women with normal BMD had higher BMI, total and truncal fat mass, as well lean mass as compared to women with osteoporosis and osteopenia (all p

  18. Total photoionization cross-sections of excited electronic states by the algebraic diagrammatic construction-Stieltjes-Lanczos method.

    Science.gov (United States)

    Ruberti, M; Yun, R; Gokhberg, K; Kopelke, S; Cederbaum, L S; Tarantelli, F; Averbukh, V

    2014-05-14

    Here, we extend the L2 ab initio method for molecular photoionization cross-sections introduced in Gokhberg et al. [J. Chem. Phys. 130, 064104 (2009)] and benchmarked in Ruberti et al. [J. Chem. Phys. 139, 144107 (2013)] to the calculation of total photoionization cross-sections of molecules in electronically excited states. The method is based on the ab initio description of molecular electronic states within the many-electron Green's function approach, known as algebraic diagrammatic construction (ADC), and on the application of Stieltjes-Chebyshev moment theory to Lanczos pseudospectra of the ADC electronic Hamiltonian. The intermediate state representation of the dipole operator in the ADC basis is used to compute the transition moments between the excited states of the molecule. We compare the results obtained using different levels of the many-body theory, i.e., ADC(1), ADC(2), and ADC(2)x for the first two excited states of CO, N2, and H2O both at the ground state and the excited state equilibrium or saddle point geometries. We find that the single excitation ADC(1) method is not adequate even at the qualitative level and that the inclusion of double electronic excitations for description of excited state photoionization is essential. Moreover, we show that the use of the extended ADC(2)x method leads to a substantial systematic difference from the strictly second-order ADC(2). Our calculations demonstrate that a theoretical modelling of photoionization of excited states requires an intrinsically double excitation theory with respect to the ground state and cannot be achieved by the standard single excitation methods with the ground state as a reference.

  19. Renal toxicity in children undergoing total body irradiation for bone marrow transplant

    International Nuclear Information System (INIS)

    Esiashvili, Natia; Chiang, K.-Y.; Hasselle, Michael D.; Bryant, Cynthia; Riffenburgh, Robert H.; Paulino, Arnold C.

    2009-01-01

    Purpose: Contribution of total body irradiation (TBI) to renal toxicity in children undergoing the bone marrow transplant (BMT) remains controversial. We report our institutional retrospective study that evaluates the frequency of acute and chronic renal dysfunction in children after using total body irradiation (TBI) conditioning regimens. Materials and methods: Between 1995 and 2003, 60 children with hematological malignancies underwent TBI as part of a conditioning regimen before allogeneic BMT. Patients received 4-14 Gy at 1.75-2 Gy/fraction in six-eight fractions. Lung shielding was used in all patients to limit lung dose to less than 10 Gy; renal shielding was not utilized. All patients had baseline renal function assessment and renal dysfunction post-BM was mainly evaluated on the basis of persistent serum creatinine elevation at acute (0-90 days) and chronic (>90 days) intervals after completion of BMT. Results: Acute renal dysfunction (ARD) was documented in 27 patients (45%); the majority had concurrent diagnosis of veno-occlusive disease (VOD) or graft-versus-host disease (GVHD) and other potential causes (sepsis, antibiotic). The risk for delayed renal dysfunction (DRD) at 1 year approached 25% for surviving patients. The ARD was strongly linked with the risk of the DRD. There was no statistically significant relationship between ARD, DRD and underlying diagnosis, GVHD, VOD or TBI doses with both univariate and multivariate analyses. The younger age (<5 years) had significantly increased risk for the development of ARD (p = 0.011). Conclusion: Our analysis validates high incidence of renal dysfunction in the pediatric BMT population. In contrast to other reports we did not find total body irradiation dose to be a risk factor for renal dysfunction. Future prospective studies are needed to assess risk factors and interventions for this serious toxicity in children following allogeneic BM

  20. Nation-wide anthropometric survey data in Japan to determine dimensions of total-body phantom for Reference Japanese Man

    International Nuclear Information System (INIS)

    Togo, Masami

    1990-01-01

    In order to estimate radiation dose in Japanese population accurately, a Reference Japanese Man, whose stature and body weight are 170cm and 60kg respectively, is indispensable. The MIRD 5 total-body phantom has only 8 dimensions, i.e. total head height, head length, head breadth, trunk length, trunk breadth, leg length, and breadth and depth of a leg model at its lower end. Based on Japanese anthropometric data, the dimensions were determined and its mathematical descriptions were given. In Japan, annual statistical data of stature, body weight, chest circumference and sitting height for all Japan by sex and age are published. But other nation-wide survey data necessary for determining dimensions of total-body phantom of Reference Japanese Man, are unavailable. Much more national anthropometric data of every kind necessary for defining phantoms must be compiled. (author)

  1. Chondrosarcoma arising within a radiation-induced osteochondroma several years following childhood total body irradiation: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Shuji [Kurume University Hospital, Department of Radiology, Fukuoka (Japan); Shen, Robert K. [Mayo Clinic, Department of Surgery, Rochester, MN (United States); Laack, Nadia N. [Mayo Clinic, Department of Radiation Oncology, Rochester, MN (United States); Inwards, Carrie Y. [Mayo Clinic, Department of Pathology, Rochester, MN (United States); Wenger, Doris E.; Amrami, Kimberly K. [Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2013-08-15

    Malignant degeneration arising in radiation-induced osteochondromas is extremely rare. We report a case of a 34-year-old man with a chondrosarcoma arising from an osteochondroma of the left posterior eighth rib that developed following total body irradiation received as part of the conditioning regimen prior to bone marrow transplantation at age 8. To our knowledge, this is only the fourth reported case of a chondrosarcoma arising within a radiation-induced osteochondroma and the first case occurring following childhood total body irradiation. (orig.)

  2. Chondrosarcoma arising within a radiation-induced osteochondroma several years following childhood total body irradiation: Case report

    International Nuclear Information System (INIS)

    Nagata, Shuji; Shen, Robert K.; Laack, Nadia N.; Inwards, Carrie Y.; Wenger, Doris E.; Amrami, Kimberly K.

    2013-01-01

    Malignant degeneration arising in radiation-induced osteochondromas is extremely rare. We report a case of a 34-year-old man with a chondrosarcoma arising from an osteochondroma of the left posterior eighth rib that developed following total body irradiation received as part of the conditioning regimen prior to bone marrow transplantation at age 8. To our knowledge, this is only the fourth reported case of a chondrosarcoma arising within a radiation-induced osteochondroma and the first case occurring following childhood total body irradiation. (orig.)

  3. Renal toxicity after total body irradiation

    International Nuclear Information System (INIS)

    Borg, Martin; Hughes, Timothy; Horvath, Noemi; Rice, Michael; Thomas, Anthony C.

    2002-01-01

    Purpose: To evaluate the incidence of renal dysfunction after total body irradiation (TBI). Methods and Materials: Between 1990 and 1997, 64 patients (median age 50 years) received TBI as part of the conditioning regimen before bone marrow transplantation (BMT). Five patients with abnormal renal function at the beginning of treatment or with incomplete data were excluded. All patients received a total of 12 Gy (6 fractions twice daily for 3 consecutive days) prescribed to the peak lung dose (corrected for lung transmission) at a dose rate of 7.5 cGy/min. Renal shielding was not used. Renal dysfunction was assessed on the basis of the serum creatinine levels measured at the start and end of TBI and at 6, 12, 18, and 24 months after completion of BMT. Cox proportional hazard analysis was used to evaluate the various factors known to affect renal function. Results: Only 4 patients had elevated serum creatinine levels at 12 months and subsequently only 2 of the 33 surviving patients had persistent elevated renal serum creatinine levels 24 months after BMT. A fifth patient developed proteinuria and mildly elevated serum creatinine levels at 2.5 years. In 2 patients, the elevation coincided with disease relapse and normalized once remission was achieved. In the third patient, the elevation in serum creatinine levels coincided with relapse of multiple myeloma and the presence of Bence-Jones proteinuria. The fourth patient was the only patient who developed chronic renal failure secondary to radiation nephritis at 2 years. The etiology of the fifth patient's rise in creatinine was unknown, but may have been secondary to radiation nephritis. On univariate analysis, but not on multivariate analysis, a significant correlation was found between TBI-related renal dysfunction and hypertension before and after BMT. Conclusion: A dose of 12 Gy at 2 Gy/fraction resulted in only 1 case of radiation nephritis in the 59 patients studied 24 months after the completion of TBI and BMT

  4. The total body length and body weight examination among gabus Sentani fish population, Oxyeleotris heterodon, Weber 1907 (Pisces: Eleotridae) of Sentani lake, Papua, Indonesia

    Science.gov (United States)

    Sriyani, E. D.; Abinawanto, Bowolaksono, A.

    2017-07-01

    The gabus Sentani fish lived in the Sentani Lake, Papua, since million years ago. Nowadays, the population of those species is getting extinct because of the overexploitation, whereas the culture effort of this species has not been developed, yet. The purpose of the study was to examine the total body length and body weight collected from some villages surrounding Sentani Lake such as Ifar village, Sosiri village, and Putali village. The body weight average of gabus fish from Ifar village, Sosiri village, and Putali village were 373.53 g, 426.86 g, and 118.34 g respectively. While the total body length average of gabus Sentani fish from Ifar village, Sosiri village, and Putali village were 279.30 mm, 223.30 mm and 222.06 mm, respectively. The growth model was W = 0.021067L3.086 with R2 value was 35.8 %, and r value was 0.598. Gabus Sentani fish, Oxyeleotris heterodon (Weber 1907) exhibited positive allometric (b > 3).

  5. Whole-body irradiation technique: physical aspects; Tecnica de irradiacion corporal total: aspectos fisicos

    Energy Technology Data Exchange (ETDEWEB)

    Venencia, D.; Bustos, S.; Zunino, S. [Instituto Privado de Radioterapia. Obispo Oro 425. Cordoba 5000 (Argentina)

    1998-12-31

    The objective of this work has been to implement a Total body irradiation technique that fulfill the following conditions: simplicity, repeatability, fast and comfortable positioning for the patient, homogeneity of the dose between 10-15 %, short times of treatments and In vivo dosimetric verifications. (Author)

  6. Characterization of intact subcellular bodies in whole bacteria by cryo-electron tomography and spectroscopic imaging.

    Science.gov (United States)

    Comolli, L R; Kundmann, M; Downing, K H

    2006-07-01

    We illustrate the combined use of cryo-electron tomography and spectroscopic difference imaging in the study of subcellular structure and subcellular bodies in whole bacteria. We limited our goal and focus to bodies with a distinct elemental composition that was in a sufficiently high concentration to provide the necessary signal-to-noise level at the relatively large sample thicknesses of the intact cell. This combination proved very powerful, as demonstrated by the identification of a phosphorus-rich body in Caulobacter crescentus. We also confirmed the presence of a body rich in carbon, demonstrated that these two types of bodies are readily recognized and distinguished from each other, and provided, for the first time to our knowledge, structural information about them in their intact state. In addition, we also showed the presence of a similar type of phosphorus-rich body in Deinococcus grandis, a member of a completely unrelated bacteria genus. Cryo-electron microscopy and tomography allowed the study of the biogenesis and morphology of these bodies at resolutions better than 10 nm, whereas spectroscopic difference imaging provided a direct identification of their chemical composition.

  7. Stress-reaction during hypokinesia and its effect on total resistance of the animal body

    International Nuclear Information System (INIS)

    Chernov, I.P.

    1980-01-01

    In the experiments on rats, shown has been that three-phase stress-reaction develops during the hypokinetic syndrome formation. This reaction is confirmed by specific changes of general state of the organism, body mass and by the activity of hypothalamic-hypophysial-adrenal system evaluated by oscillations of relative mass of pituitary body and adrenal glands and by karyometry of neuron of the hypothalamus arcuate nuclear and cells of zona fasciculata of adrenal glands. The hypokinetic stress affects the total resistance of the body, its sensitivity to gamma-irradiation in the dose of 800 rad. On the definite stage of development the hypokinetic stress forms the state of heightened ''cross'' stability

  8. Influence of physical activity on the metabolism and the total body content of sodium and potassium in the rat

    International Nuclear Information System (INIS)

    Yeh, J.K.; Yasumura, A.; Aloia, J.F.

    1986-01-01

    The purpose of this study was to investigate the effect of exercise (EX) and immobilization (IMB) on the absorption, excretion and total body content of sodium (TBNa) and potassium (TBK). Female Sprague Dawley rats 5 weeks old were divided into four groups: EX; Control (CON); EX with pair feeding to the level equal to the CON (EX-P); IMB by sciatica denervation. The nutritional balance study data was taken 5 weeks into the experimental period and the animals were sacrificed after 5 additional weeks of experimentation. The carcasses were kept frozen and used for total body composition by neutron activation. The results of the total body composition show that EX resulted in an increase, IMB resulted in a decrease, of the TBNa and TBK. There was no significant difference in TBNa of TBK, between the EX and the EX-P groups even though, the food intake was higher in the EX group. The results of the nutritional balance study confirmed the results of the total body composition

  9. Total-body photography in skin cancer screening: the clinical utility of standardized imaging.

    Science.gov (United States)

    Rosenberg, Alexandra; Meyerle, Jon H

    2017-05-01

    Early detection of skin cancer is essential to reducing morbidity and mortality from both melanoma and nonmelanoma skin cancers. Total-body skin examinations (TBSEs) may improve early detection of malignant melanomas (MMs) but are controversial due to the poor quality of data available to establish a mortality benefit from skin cancer screening. Total-body photography (TBP) promises to provide a way forward by lowering the costs of dermatologic screening while simultaneously leveraging technology to increase patient access to dermatologic care. Standardized TBP also offers the ability for dermatologists to work synergistically with modern computer technology involving algorithms capable of analyzing high-quality images to flag concerning lesions that may require closer evaluation. On a population level, inexpensive TBP has the potential to increase access to skin cancer screening and it has several specific applications in a military population. The utility of standardized TBP is reviewed in the context of skin cancer screening and teledermatology.

  10. In vivo dosimetry with silicon diodes in total body irradiation

    International Nuclear Information System (INIS)

    Oliveira, F.F.; Amaral, L.L.; Costa, A.M.; Netto, T.G.

    2014-01-01

    The aim of this work is the characterization and application of silicon diode detectors for in vivo dosimetry in total body irradiation (TBI) treatments. It was evaluated the diode response with temperature, dose rate, gantry angulations and field size. A maximum response variation of 2.2% was obtained for temperature dependence. The response variation for dose rate and angular was within 1.2%. For field size dependence, the detector response increased with field until reach a saturation region, where no more primary radiation beam contributes for dose. The calibration was performed in a TBI setup. Different lateral thicknesses from one patient were simulated and then the calibration factors were determined by means of maximum depth dose readings. Subsequent to calibration, in vivo dosimetry measurements were performed. The response difference between diode readings and the prescribed dose for all treatments was below 4%. This difference is in agreement as recommended by the International Commission on Radiation Units and Measurements (ICRU), which is ±5%. The present work to test the applicability of a silicon diode dosimetry system for performing in vivo dose measurements in TBI techniques presented good results. These measurements demonstrated the value of diode dosimetry as a treatment verification method and its applicability as a part of a quality assurance program in TBI treatments. - Highlights: ► Characterization of a silicon diode dosimetry system. ► Application of the diodes for in vivo dosimetry in total body irradiation treatments. ► Implementation of in vivo dosimetry as a part of a quality assurance program in radiotherapy

  11. Can tritiated water-dilution space accurately predict total body water in chukar partridges

    International Nuclear Information System (INIS)

    Crum, B.G.; Williams, J.B.; Nagy, K.A.

    1985-01-01

    Total body water (TBW) volumes determined from the dilution space of injected tritiated water have consistently overestimated actual water volumes (determined by desiccation to constant mass) in reptiles and mammals, but results for birds are controversial. We investigated potential errors in both the dilution method and the desiccation method in an attempt to resolve this controversy. Tritiated water dilution yielded an accurate measurement of water mass in vitro. However, in vivo, this method yielded a 4.6% overestimate of the amount of water (3.1% of live body mass) in chukar partridges, apparently largely because of loss of tritium from body water to sites of dissociable hydrogens on body solids. An additional source of overestimation (approximately 2% of body mass) was loss of tritium to the solids in blood samples during distillation of blood to obtain pure water for tritium analysis. Measuring tritium activity in plasma samples avoided this problem but required measurement of, and correction for, the dry matter content in plasma. Desiccation to constant mass by lyophilization or oven-drying also overestimated the amount of water actually in the bodies of chukar partridges by 1.4% of body mass, because these values included water adsorbed onto the outside of feathers. When desiccating defeathered carcasses, oven-drying at 70 degrees C yielded TBW values identical to those obtained from lyophilization, but TBW was overestimated (0.5% of body mass) by drying at 100 degrees C due to loss of organic substances as well as water

  12. Total lymphoid irradiation and total body irradiation for allogeneic bone marrow transplantation in aplastic anemia

    Energy Technology Data Exchange (ETDEWEB)

    Kurisu, Koichi; Hishikawa, Yoshio; Taniguchi, Midori; Kamikonya, Norihiko; Miura, Takashi; Kanamaru, Akihisa; Kakishita, Eizo; Kai, Shunro; Hara, Hiroshi (Hyogo Coll. of Medicine, Nishinomiya (Japan))

    Between April 1980 and June 1989, 15 patients with severe aplastic anemia (SAA) were treated at Hyogo College of Medicine with bone marrow transplantation (BMT) after preparation consisting of cyclophosphamide (CY) and total lymphoid irradiation (TLI) or total body irradiation (TBI) for the purpose of reducing the incidence of graft rejection. All patients had initial evidence of engraftment after the first transplantation except for one patient who died of heart failure due to CY on the third day after transplantation and could not be evaluated for engraftment. Rejection later occurred in four of these 14 patients, who then underwent successful regrafting. One of these four patients, who was conditioned with CY alone at the first grafting, underwent successful regrafting after a conditioning regimen of CY and TBI. In the other three patients, irradiation was performed twice as the conditioning regimen. Thus, 14 of 15 patients underwent successful BMT and are alive with restored hematopoietic function. From the above results, the combination of TLI or TBI and CY was considered to be very useful as a conditioning regimen for BMT in patients with SAA. (author).

  13. Total body irradiation in bone marrow transplantation

    International Nuclear Information System (INIS)

    Gluckman, E.; Devergie, A.; Boiron, M.; Bernard, Jean; Dutreix, A.; Dutreix, J.

    1979-01-01

    Total body irradiation was used in 22 patients as part of their conditioning regimen for bone marrow transplantation. Nine patients with acute leukemia received 1000 cGy TBI in addition with chemotherapy. None of them survived and the main cause of death was interstitial pneumonitis (50%). 4 patients received 1000 cGy with a lung shielding of 500 cGy. Two patients with acute leukemia died of leukemia and sepsis, two patients had aplastic anemia, one is surviving, the other died of severe GVHD and infectious complications. Nine patients with severe aplastic anemia strongly immunized by previous blood transfusions received 800 cGy TBI with a lung shielding of 400 cGy. No rejection was observed and 7 patients (63%) are currently alive. One patient died of interstitial pneumonitis probably related to CMV infection, one of subacute necrotizing hepatitis, two of severe acute GVHD. It is concluded from this study that TBI remains the best immunosuppressive conditioning regimen even in strongly immunized patients. It may be a contributing factor of the incidence and severity of interstitial pneumonitis. A reduction of the dose of the lung to 400-500 cGy seems to decrease the severity of this complication

  14. Radiobiological speculations on therapeutic total body irradiation

    International Nuclear Information System (INIS)

    Vriesendorp, H.M.

    1990-01-01

    Unexpected total body irradiation (TBI) of human beings, involved in nuclear warfare or in accidents in nuclear reactors can be lethal. In the 1950s, bone marrow transplantation was discovered as a potentially life saving procedure after TBI in the dose range of 5.0 to 12.0 Gy. Since that time, deliberate or therapeutic TBI has been used to condition patients with a lethal bone marrow disorder for bone marrow replacement. The therapeutic ratio of TBI followed by bone marrow transplantation is small. Many potentially lethal complications can occur, such as acute TBI side effects, late TBI side effects or immunological complications of bone marrow transplantation such as graft versus host disease or graft rejection. The benefits of TBI and bone marrow transplantation are that they offer a chance for cure of previously lethal bone marrow disorders. The optimal parameters for TBI remain to be defined. The review discusses the current clinical and experimental animal data, as they relate to the future definition of less toxic TBI procedures with a better therapeutic ratio. Different TBI procedures are required for patients with malignant vs. non-malignant disorders or for patients with histoincompatible vs. histocompatible bone marrow donors.77 references

  15. A semi-empirical formula for total cross sections of electron scattering from diatomic molecules

    International Nuclear Information System (INIS)

    Liu Yufang; Sun Jinfeng; Henan Normal Univ., Xinxiang

    1996-01-01

    A fitting formula based on the Born approximation is used to fit the total cross sections for electron scattering by diatomic molecules (CO, N 2 , NO, O 2 and HCl) in the intermediate- and high-energy range. By analyzing the fitted parameters and the total cross sections, we found that the internuclear distance of the constituent atoms plays an important role in the e-diatomic molecule collision process. Thus a new semi-empirical formula has been obtained. There is no free parameter in the formula, and the dependence of the total cross sections on the internuclear distance has been reflected clearly. The total cross sections for electron scattering by CO, N 2 , NO, O 2 and HCl have been calculated over an incident energy range of 10-4000 eV. The results agree well with other available experimental and calculation data. (orig.)

  16. Total Energy Expenditure, Energy Intake, and Body Composition in Endurance Athletes Across the Training Season: A Systematic Review.

    Science.gov (United States)

    Heydenreich, Juliane; Kayser, Bengt; Schutz, Yves; Melzer, Katarina

    2017-12-01

    Endurance athletes perform periodized training in order to prepare for main competitions and maximize performance. However, the coupling between alterations of total energy expenditure (TEE), energy intake, and body composition during different seasonal training phases is unclear. So far, no systematic review has assessed fluctuations in TEE, energy intake, and/or body composition in endurance athletes across the training season. The purpose of this study was to (1) systematically analyze TEE, energy intake, and body composition in highly trained athletes of various endurance disciplines and of both sexes and (2) analyze fluctuations in these parameters across the training season. An electronic database search was conducted on the SPORTDiscus and MEDLINE (January 1990-31 January 2015) databases using a combination of relevant keywords. Two independent reviewers identified potentially relevant studies. Where a consensus was not reached, a third reviewer was consulted. Original research articles that examined TEE, energy intake, and/or body composition in 18-40-year-old endurance athletes and reported the seasonal training phases of data assessment were included in the review. Articles were excluded if body composition was assessed by skinfold measurements, TEE was assessed by questionnaires, or data could not be split between the sexes. Two reviewers assessed the quality of studies independently. Data on subject characteristics, TEE, energy intake, and/or body composition were extracted from the included studies. Subjects were categorized according to their sex and endurance discipline and each study allocated a weight within categories based on the number of subjects assessed. Extracted data were used to calculate weighted means and standard deviations for parameters of TEE, energy intake, and/or body composition. From 3589 citations, 321 articles were identified as potentially relevant, with 82 meeting all of the inclusion criteria. TEE of endurance athletes was

  17. Energy Harvesting from the Animal/Human Body for Self-Powered Electronics.

    Science.gov (United States)

    Dagdeviren, Canan; Li, Zhou; Wang, Zhong Lin

    2017-06-21

    Living subjects (i.e., humans and animals) have abundant sources of energy in chemical, thermal, and mechanical forms. The use of these energies presents a viable way to overcome the battery capacity limitation that constrains the long-term operation of wearable/implantable devices. The intersection of novel materials and fabrication techniques offers boundless possibilities for the benefit of human health and well-being via various types of energy harvesters. This review summarizes the existing approaches that have been demonstrated to harvest energy from the bodies of living subjects for self-powered electronics. We present material choices, device layouts, and operation principles of these energy harvesters with a focus on in vivo applications. We discuss a broad range of energy harvesters placed in or on various body parts of human and animal models. We conclude with an outlook of future research in which the integration of various energy harvesters with advanced electronics can provide a new platform for the development of novel technologies for disease diagnostics, treatment, and prevention.

  18. Total electron scattering cross sections for methanol and ethanol at intermediate energies

    International Nuclear Information System (INIS)

    Silva, D G M; Tejo, T; Lopes, M C A; Muse, J; Romero, D; Khakoo, M A

    2010-01-01

    Absolute total cross section (TCS) measurements of electron scattering from gaseous methanol and ethanol molecules are reported for impact energies from 60 to 500 eV, using the linear transmission method. The attenuation of intensity of a collimated electron beam through the target volume is used to determine the absolute TCS for a given impact energy, using the Beer-Lambert law to first approximation. Besides these experimental measurements, we have also determined TCS using the additivity rule.

  19. Comparative evolution of coagulation disorders in baboons and Pigs after total body irradiation

    International Nuclear Information System (INIS)

    Destombe, C.; Lefleche, P.; Veyret, J.; Grasseau, A.; Agay, D.; Mestries, J.C.

    1994-01-01

    Acute total body irradiation in pigs, with a lethal dose of either gamma or mixed gamma-neutron radiation, induced similar plasmatic coagulation disorders as those observed in baboons. These data validated pathophysiological hypothesis which were developed during previous studies, but do not support the idea of a possible species specific radiosensitivity. (author)

  20. Association between electronic equipment in the bedroom and sedentary lifestyle, physical activity, and body mass index of children.

    Science.gov (United States)

    Ferrari, Gerson Luis de Moraes; Araújo, Timóteo Leandro; Oliveira, Luis Carlos; Matsudo, Victor; Fisberg, Mauro

    2015-01-01

    To describe the association between electronic devices in the bedroom with sedentary time and physical activity, both assessed by accelerometry, in addition to body mass index in children from São Caetano do Sul. The sample consisted of 441 children. The presence of electronic equipment (television, personal computer, and videogames) in the bedroom was assessed by a questionnaire. For seven consecutive days, children used an accelerometer to objectively monitor the sedentary time and moderate-to-vigorous physical activity. Body mass index was categorized as suggested by the World Health Organization. Overall, 73.9%, 54.2% and 42.8% of children had TV, computer, and videogames in the bedroom, respectively, and spent an average of 500.7 and 59.1 min/day of sedentary time and moderate-to-vigorous physical activity. Of the children, 45.3% were overweight/obese. Girls with a computer in the bedroom (45 min/day) performed less moderate-to-vigorous physical activity than those without it (51.4 min/day). Similar results were observed for body mass index in boys. Moderate-to-vigorous physical activity was higher and body mass index was lower in children that had no electronic equipment in the bedroom. Presence of a computer (β=-4.798) and the combination TV+computer (β=-3.233) were negatively associated with moderate-to-vigorous physical activity. Videogames and the combinations with two or three electronic devices were positively associated with body mass index. Sedentary time was not associated with electronic equipment. Electronic equipment in the children's bedroom can negatively affect moderate-to-vigorous physical activity and body mass index regardless of gender, school, and annual family income, which can contribute to physical inactivity and childhood obesity. Copyright © 2015 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  1. Total yield and escape depth of electrons from heavy ion solid interactions

    International Nuclear Information System (INIS)

    Frischkorn, H.J.; Burkhard, M.; Groenveld, K.O.; Hofmann, D.; Koschar, P.; Latz, R.; Schader, J.

    1983-01-01

    At high projectile energies ( aboutMeV/U) several mechanisms for electron production are discussed as e.g. direct ionization collisions, recoil particle cascades, collective electron emission. Results are presented of total electron yield (#betta#) measurements over a wide projectile energy E /SUB p/ range (40 keV/U< E /SUB p/ /M <12 MeV/U) and a wide projectile Z /SUB p/ range (1<2 /SUB p-/ <92) of both monoionic and molecular projectiles and of different target thicknesses. From the target thickness dependence of #betta# the mean free path lambda of electrons in carbon can be calculated. The data are discussed in the frame of current theories. Significant deviations from calculated values and predicted dependencies are found, in particular for projectile velocities v /SUB p/ close to the Fermi velocity v /SUB F/ of target electrons and for molecular projectile ions

  2. Dosimetry for total body irradiation of rhesus monkeys with 300 kV X- rays

    NARCIS (Netherlands)

    Zoetelief, J.; Wagemaker, G.; Broerse, J.J.

    1998-01-01

    Purpose: To obtain more accurate information on the dose distribution in rhesus monkeys for total body irradiation with orthovoltage X-rays. Materials and methods: Dose measurements were performed with an ionization chamber inside homogeneous cylindrical and rectangular phantoms of various

  3. Post-laryngectomy localization of I-131 at tracheostomy site on a total body scan

    International Nuclear Information System (INIS)

    Kirk, G.A.; Schulz, E.E.

    1984-01-01

    A post-thyroidectomy, post-I-131-therapy patient had a laryngectomy and neck dissection for recurrent papillary thyroid carcinoma. A subsequent I-131 total body scan revealed persistent anterior neck activity, which disappeared upon removal of the tracheostomy tube and dressings

  4. THE URINE PROTEOME FOR RADIATION BIODOSIMETRY: EFFECT OF TOTAL BODY VERSUS LOCAL KIDNEY IRRADIATION

    Science.gov (United States)

    Sharma, Mukut; Halligan, Brian D.; Wakim, Bassam T.; Savin, Virginia J.; Cohen, Eric P.; Moulder, John E.

    2009-01-01

    Victims of nuclear accidents or radiological terrorism are likely to receive varying doses of ionizing radiation inhomogeneously distributed over the body. Early biomarkers may be useful in determining organ-specific doses due to total body irradiation (TBI) or partial body irradiation. We used liquid chromatography and mass spectrometry to compare the effect of TBI and local kidney irradiation (LKI) on the rat urine proteome using a single 10 Gy dose of X-rays. Both TBI and LKI altered the urinary protein profile within 24 hours with noticeable differences in Gene Ontology categories. Some proteins including fetuin-B, tissue kallikrein, beta-glucuronidase, vitamin D-dependent calcium binding protein and chondroitin sulfate proteoglycan NG2 were detected only in the TBI group. Some other proteins including major urinary protein-1, RNA binding protein 19, neuron navigator, Dapper homolog 3, WD repeat and FYVE domain containing protein 3, sorting nexin-8, ankycorbin and aquaporin were detected only in the LKI group. Protease inhibitors and kidney proteins were more abundant (fraction of total scans) in the LKI group. Up/Uc ratio and urinary albumin abundance decreased in both TBI and LKI groups. Several markers of acute kidney injury were not detectable in either irradiated group. Present data indicate that abundance and number of proteins may follow opposite trends. These novel findings demonstrate intriguing differences between TBI and LKI, and suggest that urine proteome may be useful in determining organ-specific changes caused by partial body irradiation. PMID:20065682

  5. Total body retention of orally administered 47Ca in primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Mallette, L.E.; Sode, J.E.; Marx, S.J.; Georges, L.P.; Aurbach, G.D.

    1975-01-01

    Using a whole-body radiation detector, the total-body retention of 47 Ca 7 days after oral administration of the isotope to patients with various disorders of calcium metabolism was measured. The percent retention of 47 Ca given with 90 mg of unlabeled (carrier) calcium varied with the calcium metabolic status as follows: normals (n = 14), 33--43 percent (mean 38); primary hyperparathyroidism (n = 28), 32--74 percent (mean 52); idiopathic hypercalciuria (n = 9), 34--49 percent (mean 42); and hypercalcemia of other etiology (n = 3), 23--26 percent (mean 25). Almost half (13/28) of those with hyperparathyroidism showed a retention above 55 percent, distinguishing them from subjects with idiopathic hypercalciuria. Retention of 47 Ca correlated poorly with clinical measures of severity of hyperparathyroidism. When isotope was diluted with a smaller amount of carrier calcium (20 mg), retention was increased in normals (n = 5) to 46--54 percent (mean 50) and in hyperparathyroidism (n = 5) to 64--87 percent (mean 73). After surgical cure of hyperparathyroidism retention of isotope returned toward normal in 5 of 7 subjects. Whole-body retention of orally administered 47 Ca may prove useful in detecting hyperparathyroidism in subjects with mild hypercalcemia or hypercalciuria. (U.S.)

  6. The Role of Electron Transport and Trapping in MOS Total-Dose Modeling

    International Nuclear Information System (INIS)

    Flament, O.; Fleetwood, D.M.; Leray, J.L.; Paillet, P.; Riewe, L.C.; Winokur, P.S.

    1999-01-01

    Deep and shallow electron traps form in irradiated thermal SiO 2 as a natural response to hole transport and trapping. The density and stability of these defects are discussed, as are their implications for total-dose modeling

  7. The effect of total-body γ-irradiation on pigeons

    International Nuclear Information System (INIS)

    Gadhia, P.K.; Shah, V.C.; Desai, R.

    1979-01-01

    A study of the effects of total-body 60 Coγ radiation (200 to 2000 rad) on the common pigeon (Columba livia) has indicated a LD 50/30 of 950 +- 50 rad. There were no deaths before 6 days and the peak frequency in average deaths occurred 9 days after irradiation. Most of the birds showed small changes in activity or behaviour in the first five days. A histopathological study was made of femoral bone marrow from irradiated (1000 rad) pigeons sacrificed 1 to 18 days post-irradiation. Slight aplasia was observed on the first day after irradiation, moderately marked on the third day and extensive on the fourth and fifth days. At the end of the second week regeneration was observed as the primitive lymphocyte-like cells were differentiating into granulocytes and erythrocytes. (UK)

  8. Intake at a single, palatable buffet test meal is associated with total body fat and regional fat distribution in children.

    Science.gov (United States)

    Fearnbach, S Nicole; Thivel, David; Meyermann, Karol; Keller, Kathleen L

    2015-09-01

    Previous studies testing the relationship between short-term, ad libitum test-meal intake and body composition in children have shown inconsistent relationships. The objective of this study was to determine whether children's intake at a palatable, buffet meal was associated with body composition, assessed by dual-energy X-ray absorptiometry (DXA). A sample of 71 children (4-6 years) participated in 4 sessions where ad libitum food intake was measured. Children's intake at two of the test-meals was retained for the present analysis: a baseline meal consisting of moderately palatable foods and a highly palatable buffet including sweets, sweet-fats, and savory-fats. On the last visit, anthropometrics and DXA were assessed to determine child body composition. Children consumed significantly more calories at the palatable buffet compared to the baseline test-meal. Children's total fat-free mass was positively associated with intake at both the baseline meal and the palatable buffet meal. Total energy intake at both meals and intake of savory-fats at the palatable buffet were positively associated with children's total fat mass, total percent body fat, and percent android fat. Intake of sweet-fats was associated with child fat-free mass index. Intake of sweets was not correlated with body composition. Children's intake at a palatable test-meal, particularly of savory-fat foods, was associated with measures of total and regional body fat. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Measurement of total-body cobalt-57 vitamin B12 absorption with a gamma camera

    International Nuclear Information System (INIS)

    Cardarelli, J.A.; Slingerland, D.W.; Burrows, B.A.; Miller, A.

    1985-01-01

    Previously described techniques for the measurement of the absorption of [ 57 Co]vitamin B 12 by total-body counting have required an iron room equipped with scanning or multiple detectors. The present study uses simplifying modifications which make the technique more available and include the use of static geometry, the measurement of body thickness to correct for attenuation, a simple formula to convert the capsule-in-air count to a 100% absorption count, and finally the use of an adequately shielded gamma camera obviating the need of an iron room

  10. Comparison of 24 hr total body radio-iodine retention for hypothyroid vs. thyrogen (rhTSH) stimulated whole body surveillance scan

    International Nuclear Information System (INIS)

    Jana, S.; Young, I.; Bukberg, P.; Luo, J.Q.; Dakhel, M.; Heiba, S.; El-Zeftawy, H.; Abdel-Dayem, H.M.

    2002-01-01

    Objective: Recently rhTSH has been used for WBS to avoid hypothyroid symptoms from T4/T3 withdrawal. There is limited data available in the current literature comparing total body radio-iodine clearance between hypothyroid pts and pts receiving rhTSH. Significant differences in radio-iodine clearance may influence the dose of radio-iodine required for diagnostic scanning or treatment of pts on a rhTSH protocol. Methods: To retrospectively compare the 24 hr total body I-123 retention in thyroid cancer pts who were made hypothyroid in preparation for radio-iodine scanning with the I-123 retention in pts who received thyrogen (rhTSH) but were maintained on thyroid hormone replacement. Inclusion criteria were as follows: Histologically diagnosed well diff. thyroid Ca s/p surgery and I-131 Rx in the past who were clinically disease free at the time of scanning. No abn. visible I-123 uptake on WBS and 24 hr neck uptake ≤ 1%. Tg level ≤ 2ng off T4/T3 or ≤ 2ng increase from basal level after rhTSH. Anti-Tg Ab negative. Serum Creatine ≤ 1.4 mg/dl. Serum ALT < 35, AST < 35. Total 78 pts were divided into the following 3 groups (Gp): Gp-1 (29 pts) received 2 IM inj. Of 0.9 mg rhTSH 24 and 48 hrs prior to oral dose of 10 mCi I-123. Gp-2 (30 pts) followed hypothyroid protocol i.e., off T4 ≥ 4 wks or T3 ≥ 10 days in order to achieve TSH ≥ 30 MIU/L. The dose of I-123 was 5 mCi. Gp-3 (19 pts) similar to Gp-2 i.e., hypothyroid but scanned using 10 mCi of I-123. Imaging protocol: Pts were scanned 4 hrs and 24 hrs after I-123 administration in a dual head gamma camera for 30 mins. Total body and neck counting were obtained from the geometric mean of Ant and Post images with appropriate decay correction. 24 hr total body retention (TBR) of I-123 were calculated and expressed in %, considering 100% at 4 hrs. Results: Demographic Profile of 3 Patient Groups. AST/ALT was < 35 and 24 hrs neck uptake was ≤ 1.0% all pts. Comparison of 24 hr % TBR of I-123 in 3 Patient Groups

  11. Total cross sections for slow-electron (1--20 eV) scattering in solid H2O

    International Nuclear Information System (INIS)

    Michaud, M.; Sanche, L.

    1987-01-01

    An analytical method is proposed to determine absolute total cross sections per scatterer and related mean free paths for low-energy electron scattering in disordered molecular solid films. The procedure is based on a two-stream multiple-scattering model of the thickness dependence of the film reflectivity for elastic electrons. The expected analytical behavior and accuracy are tested on a model sample whose scattering properties are generated by a Monte Carlo simulation from initially known parameters. The effects of multiple scattering inside the film and at its interfaces are taken into account and discussed. The thickness dependence of the elastic electron reflectivity of H 2 O film condensed at 14 K is reported between 1 and 20 eV incident energy with a spectrometer resolution of 10 MeV. The proposed method is applied to extract from these measurements the energy dependence of the total effective and total inelastic cross sections for electron scattering in amorphous ice

  12. Electron correlation in single-electron capture from helium by fast protons

    International Nuclear Information System (INIS)

    Purkait, M

    2012-01-01

    The differential and total cross sections for single charge exchange in p-He collisions have been calculated within the framework of four-body boundary corrected continuum intermediate state (BCCIS-4B) approximation. The effect of dynamic electron correlations is explicitly taken into account through the complete perturbation potentials.

  13. Calculations of the Total Number of Electrons Along a Ray Path Extending from the Transmitter to the Receiver

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Ionospheric Total Electron Content (TEC) is the total number of electrons in a column of unit cross section extending from the transmitter to the receiver. TEC is...

  14. The dosimetry of cobalt-60 γ-ray total body irradiation before bone marrow transplantation

    International Nuclear Information System (INIS)

    Dong Fan; Zhang Guiru

    1989-11-01

    The dosimetric considerations of using conventional cobalt-60 unit total body irradiation (TBI) are presented. By extending the source-to-midplane distance (SMD) to 346 cm, a 92 x 98 cm 2 rectangular field with diagonal dimension 134 cm was obtained. The results from the phantom measurements showed: (1) the effective field corresponding to an average-size patient is 25 x 25 cm 2 , and a method for estimating the effective field of human body is given; (2) the midplane doses are consistently higher than those of surfaces, but the dose ratio of midplane to surface decreases as the body thickness increases, and a significant negative correlation is existed between the dose ratio and thickness, thus a linear regression line is fitted; (3) the anterior-posterior (AP) or AP + bilateral irradiation will yield a more uniform dose distribution in the whole body than the bilateral irradiation; (4) the dose uniformity can apparently be improved by the tissue compensation, for which the technique is described

  15. Total cross section for chloroflouromethanes and CClx radicals by electron impact

    International Nuclear Information System (INIS)

    Gupta, Dhanoj; Antony, Bobby

    2013-01-01

    Highlights: ► A model to find total CS for freons and CCl x by e − impact is employed. ► Complex optical potential formalism is used to find total inelastic and elastic CS. ► Result shows very good agreement with previous data wherever available. ► Maiden attempt to find cross section for the CCl x radicals. -- Abstract: We report here the total cross section for chloroflouromethanes namely CCl 3 F (Freon 11), CCl 2 F 2 (Freon 12), CClF 3 (Freon 13), CCl 4 and CCl x (x = 1–3), radicals by electron impact 50 to 5000 eV. The total inelastic and elastic cross sections are obtained employing a complex optical potential formalism and solving the Schrödinger equation through partial wave analysis. The total cross section is obtained as the sum of total inelastic and elastic cross sections. The results obtained are compared with the existing experimental and theoretical data, wherever available. The present result shows reasonable agreement with previous data. For the CCl x radicals, we have predicted the total cross sections for the first time. The data reported here has immense interest to atmospheric and technological plasma modelling

  16. The Total Electron Content From InSAR and GNSS: A Midlatitude Study

    DEFF Research Database (Denmark)

    Musico, Elvira; Cesaroni, Claudio; Spogli, Luca

    2018-01-01

    The total electron content (TEC) measured from the interferometric synthetic aperture radar (InSAR) and froma dense network of global navigation satellite system (GNSS) receivers are used to assess the capability of InSAR to retrieve ionospheric information, when the tropospheric contribution...

  17. Establishment of Early Endpoints in Mouse Total-Body Irradiation Model.

    Directory of Open Access Journals (Sweden)

    Amory Koch

    Full Text Available Acute radiation sickness (ARS following exposure to ionizing irradiation is characterized by radiation-induced multiorgan dysfunction/failure that refers to progressive dysfunction of two or more organ systems, the etiological agent being radiation damage to cells and tissues over time. Radiation sensitivity data on humans and animals has made it possible to describe the signs associated with ARS. A mouse model of total-body irradiation (TBI has previously been developed that represents the likely scenario of exposure in the human population. Herein, we present the Mouse Intervention Scoring System (MISS developed at the Veterinary Sciences Department (VSD of the Armed Forces Radiobiology Research Institute (AFRRI to identify moribund mice and decrease the numbers of mice found dead, which is therefore a more humane refinement to death as the endpoint. Survival rates were compared to changes in body weights and temperatures in the mouse (CD2F1 male TBI model (6-14 Gy, 60Co γ-rays at 0.6 Gy min-1, which informed improvements to the Scoring System. Individual tracking of animals via implanted microchips allowed for assessment of criteria based on individuals rather than by group averages. From a total of 132 mice (92 irradiated, 51 mice were euthanized versus only four mice that were found dead (7% of non-survivors. In this case, all four mice were found dead after overnight periods between observations. Weight loss alone was indicative of imminent succumbing to radiation injury, however mice did not always become moribund within 24 hours while having weight loss >30%. Only one survivor had a weight loss of greater than 30%. Temperature significantly dropped only 2-4 days before death/euthanasia in 10 and 14 Gy animals. The score system demonstrates a significant refinement as compared to using subjective assessment of morbidity or death as the endpoint for these survival studies.

  18. Total body fat, abdominal fat, body fat distribution and surrogate markers for health related to adipocyte fatty acid-binding protein (FABP4) in children.

    Science.gov (United States)

    Dencker, Magnus; Danielson, Anton; Karlsson, Magnus K; Wollmer, Per; Andersen, Lars B; Thorsson, Ola

    2017-04-01

    The aim of the study was to assess possible relationships between adipocyte fatty acid-binding protein (FABP4) and total body fat (TBF), abdominal fat, body fat distribution, aerobic fitness, blood pressure, cardiac dimensions and the increase in body fat over 2 years in a community sample of children. A cross-sectional study was used in a community sample of 170 (92 boys and 78 girls) children aged 8-11 years. TBF and abdominal fat (AFM) were measured by dual-energy X-ray absorptiometry (DXA). TBF was also expressed as percentage of total body mass (BF%), and body fat distribution was calculated as AFM/TBF. Maximal oxygen uptake (VO2PEAK) was assessed by indirect calorimetry during a maximal exercise test and scaled to body mass. Systolic and diastolic blood pressure (SBP and DBP) and pulse pressure (PP) were measured. Echocardiography was performed. Left atrial (LA) size was measured, and left ventricular mass (LVM) was calculated. A follow-up DXA scan was available in 152 children (84 boys and 68 girls). Frozen serum samples were analyzed for FABP4. Partial correlations, with adjustment for sex, between FABP4 vs. ln TBF, ln BF%, ln AFM, AFM/TBF and VO2PEAK were (r=0.69, 0.68, 0.69, 0.49 and -0.39, pfat or change in fat distribution were not correlated.) Conclusions: Findings from this community-based cohort of young children show that increased body fat and abdominal fat, more abdominal body fat distribution, low fitness, more LVM and increased LA, increased SBP and PP were all associated with increased levels of FABP4. Increase in TBF and abdominal fat over 2 years were also associated with increased levels of FABP4.

  19. A prospective, open-label study of low-dose total skin electron beam therapy in mycosis fungoides

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Specht, Lena; Skovgaard, Gunhild L

    2008-01-01

    causes and did not complete treatment. Acute side effects included desquamation, xerosis, and erythema of the skin. No severe side effects were observed. CONCLUSION: Low-dose total skin electron beam therapy can induce complete and partial responses in Stage IB-II mycosis fungoides; however, the duration......PURPOSE: To determine the effect of low-dose (4 Gy) total skin electron beam therapy as a second-line treatment of Stage IB-II mycosis fungoides in a prospective, open-label study. METHODS AND MATERIALS: Ten patients (6 men, 4 women, average age 68.7 years [range, 55-82 years......]) with histopathologically confirmed mycosis fungoides T2-T4 N0-N1 M0 who did not achieve complete remission or relapsed within 4 months after treatment with psoralen plus ultraviolet-A were included. Treatment consisted of low-dose total skin electron beam therapy administered at a total skin dose of 4 Gy given in 4...

  20. The urine proteome for radiation biodosimetry: effect of total body vs. local kidney irradiation.

    Science.gov (United States)

    Sharma, Mukut; Halligan, Brian D; Wakim, Bassam T; Savin, Virginia J; Cohen, Eric P; Moulder, John E

    2010-02-01

    Victims of nuclear accidents or radiological terrorism are likely to receive varying doses of ionizing radiation inhomogeneously distributed over the body. Early biomarkers may be useful in determining organ-specific doses due to total body irradiation (TBI) or partial body irradiation. The authors used liquid chromatography and mass spectrometry to compare the effect of TBI and local kidney irradiation (LKI) on the rat urine proteome using a single 10-Gy dose of x-rays. Both TBI and LKI altered the urinary protein profile within 24 h with noticeable differences in gene ontology categories. Some proteins, including fetuin-B, tissue kallikrein, beta-glucuronidase, vitamin D-dependent calcium binding protein and chondroitin sulfate proteoglycan NG2, were detected only in the TBI group. Some other proteins, including major urinary protein-1, RNA binding protein 19, neuron navigator, Dapper homolog 3, WD repeat and FYVE domain containing protein 3, sorting nexin-8, ankycorbin and aquaporin were detected only in the LKI group. Protease inhibitors and kidney proteins were more abundant (fraction of total scans) in the LKI group. Urine protein (Up) and creatinine (Uc) (Up/Uc) ratios and urinary albumin abundance decreased in both TBI and LKI groups. Several markers of acute kidney injury were not detectable in either irradiated group. Present data indicate that abundance and number of proteins may follow opposite trends. These novel findings demonstrate intriguing differences between TBI and LKI, and suggest that urine proteome may be useful in determining organ-specific changes caused by partial body irradiation.

  1. Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy X-ray absorptiometry during prolonged weight loss

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Højgaard, L

    1996-01-01

    A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK). These measu...

  2. Total body-calcium measurements: comparison of two delayed-gamma neutron activation facilities

    International Nuclear Information System (INIS)

    Ma, R.; Ellis, K.J.; Shypailo, R.J.; Pierson, R.N. Jr.

    1999-01-01

    This study compares two independently calibrated delayed-gamma neutron activation (DGNA) facilities, one at the Brookhaven National Laboratory (BNL), Upton, New York, and the other at the Children's Nutrition Research Center (CNRC), Houston, Texas that measure total body calcium (TBCa). A set of BNL phantoms was sent to CNRC for neutron activation analysis, and a set of CNRC phantoms was measured at BNL. Both facilities showed high precision (<2%), and the results were in good agreement, within 5%. (author)

  3. Exploring the Relationship between Skeletal Mass and Total Body Mass in Birds.

    Science.gov (United States)

    Martin-Silverstone, Elizabeth; Vincze, Orsolya; McCann, Ria; Jonsson, Carl H W; Palmer, Colin; Kaiser, Gary; Dyke, Gareth

    2015-01-01

    Total body mass (TBM) is known to be related to a number of different osteological features in vertebrates, including limb element measurements and total skeletal mass. The relationship between skeletal mass and TBM in birds has been suggested as a way of estimating the latter in cases where only the skeleton is known (e.g., fossils). This relationship has thus also been applied to other extinct vertebrates, including the non-avian pterosaurs, while other studies have used additional skeletal correlates found in modern birds to estimate TBM. However, most previous studies have used TBM compiled from the literature rather than from direct measurements, producing values from population averages rather than from individuals. Here, we report a new dataset of 487 extant birds encompassing 79 species that have skeletal mass and TBM recorded at the time of collection or preparation. We combine both historical and new data for analyses with phylogenetic control and find a similar and well-correlated relationship between skeletal mass and TBM. Thus, we confirm that TBM and skeletal mass are accurate proxies for estimating one another. We also look at other factors that may have an effect on avian body mass, including sex, ontogenetic stage, and flight mode. While data are well-correlated in all cases, phylogeny is a major control on TBM in birds strongly suggesting that this relationship is not appropriate for estimating the total mass of taxa outside of crown birds, Neornithes (e.g., non-avian dinosaurs, pterosaurs). Data also reveal large variability in both bird skeletal and TBM within single species; caution should thus be applied when using published mass to test direct correlations with skeletal mass and bone lengths.

  4. Spontaneous resolution of posterior ankle joint loose bodies after total ankle replacement: A case report.

    Science.gov (United States)

    Lee, Raymond P; Cheng, Sally H S

    2017-06-01

    Late stage ankle osteoarthritis often presents with debilitating pain. It is common to find osteophytes and loose body formation around the joint. Total ankle arthroplasty can preserve joint mobility and pain relieve for such patient. However, when trying to remove the osteophytes and loose bodies at the posterior ankle joint, there is risk of damaging posterior structures such as the neurovascular bundle during the procedure. We are presenting a case where the posterior loose bodies remained untouched during the operation, and patient showed spontaneous resolution of the lesions with time. Patient enjoyed good function outcome after the surgery. Copyright © 2016 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  5. SU-E-T-522: Investigation of Underdosage of Total Body Irradiation with Bilateral Irradiation Scheme

    Energy Technology Data Exchange (ETDEWEB)

    Lin, T; Eldib, A; Hossain, M; Price, R; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2015-06-15

    Purpose: Patient in-vivo measurements report lower readings than those predicted from TMR-based treatment planning on TBI patient knees and ankles where rice was placed to fill the gap between patient’s legs. This study is to understand and correct the under dosage of Total Body Irradiation(TBI) with rice tissue equivalent bolus placement at TBI treatment patient setup. Methods: Bilateral TBI scheme was investigated with rice bags bolus placing between patient’s two legs acting as missing tissue. In-house TMR based treatment planning system was commissioned with measurements under TBI condition at 10MV, i.e. source-to-reference distance 383.4cm with 40×40cm field size with 1cm thickness Lucite. Predictions of patient specific dose points are reported at different sites with 200cGy prescription at patient umbilicus point. Solid water and rice bag phantoms are used at TBI conditions for the attenuation factor verification and CT scanned to verify the CT number and electron density. Results: We found that the rice bag bolus overall density is 11% lower than the water; however, the attenuation factor of rice bags could become 15% lower than that of water at TBI condition. This overestimate of rice bag electron density could cause the lack of lateral scatter and the lack of backscatter. This could Result in an overestimate of dose at in-vivo dosimeter measurement points with TMR-based treatment planning systems. Observations of patient specific optically stimulated luminescent dosimeters(OSLDs) were used to confirm this overestimation. Measurements of setups with increasing the rice bag filled patient leg separation were performed to demonstrate eliminating the overdose issue. Conclusion: Rice bolus has a lower electron density than water does(11%) but results in 15% lower in attenuation factor at TBI condition. This effect was observed in patient delivery with OSLD measurements and can be corrected by increasing the filling rice bolus thickness with 15% longer of

  6. SU-E-T-522: Investigation of Underdosage of Total Body Irradiation with Bilateral Irradiation Scheme

    International Nuclear Information System (INIS)

    Lin, T; Eldib, A; Hossain, M; Price, R; Ma, C

    2015-01-01

    Purpose: Patient in-vivo measurements report lower readings than those predicted from TMR-based treatment planning on TBI patient knees and ankles where rice was placed to fill the gap between patient’s legs. This study is to understand and correct the under dosage of Total Body Irradiation(TBI) with rice tissue equivalent bolus placement at TBI treatment patient setup. Methods: Bilateral TBI scheme was investigated with rice bags bolus placing between patient’s two legs acting as missing tissue. In-house TMR based treatment planning system was commissioned with measurements under TBI condition at 10MV, i.e. source-to-reference distance 383.4cm with 40×40cm field size with 1cm thickness Lucite. Predictions of patient specific dose points are reported at different sites with 200cGy prescription at patient umbilicus point. Solid water and rice bag phantoms are used at TBI conditions for the attenuation factor verification and CT scanned to verify the CT number and electron density. Results: We found that the rice bag bolus overall density is 11% lower than the water; however, the attenuation factor of rice bags could become 15% lower than that of water at TBI condition. This overestimate of rice bag electron density could cause the lack of lateral scatter and the lack of backscatter. This could Result in an overestimate of dose at in-vivo dosimeter measurement points with TMR-based treatment planning systems. Observations of patient specific optically stimulated luminescent dosimeters(OSLDs) were used to confirm this overestimation. Measurements of setups with increasing the rice bag filled patient leg separation were performed to demonstrate eliminating the overdose issue. Conclusion: Rice bolus has a lower electron density than water does(11%) but results in 15% lower in attenuation factor at TBI condition. This effect was observed in patient delivery with OSLD measurements and can be corrected by increasing the filling rice bolus thickness with 15% longer of

  7. Complexities of the storm-time characteristics of ionospheric total electron content

    International Nuclear Information System (INIS)

    Kane, R.P.

    1982-01-01

    The complexities of the storm-time variations of the ionospheric total electron content are briefly reviewed. It is suggested that large variations from storm to storm may be due to irregular flows from the auroral region towards equator. A proper study of such flows needs an elaborate network of TEC measuring instruments. The need of planning and organizing such a network is emphasized

  8. Patterns of patient specific dosimetry in total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Akino, Yuichi [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, Indiana 46202 (United States); Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Osaka 565-0871 (Japan); McMullen, Kevin P.; Das, Indra J. [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, Indiana 46202 (United States)

    2013-04-15

    Purpose: Total body irradiation (TBI) has been used for bone marrow transplant for hematologic and immune deficiency conditions. The goal of TBI is to deliver a homogeneous dose to the entire body, with a generally accepted range of dose uniformity being within {+-}10% of the prescribed dose. The moving table technique for TBI could make dose uniform in whole body by adjusting couch speed. However, it is difficult to accurately estimate the actual dose by calculation and hence in vivo dosimetry (IVD) is routinely performed. Here, the authors present patterns of patient-specific IVD in 161 TBI patients treated at our institution. Methods: Cobalt-60 teletherapy unit (Model C9 Cobalt-60 teletherapy unit, Picker X-ray Corporation) with customized moving bed (SITI Industrial Products, Inc., Fishers, IN) were used for TBI treatment. During treatment, OneDose{sup TM} (Sicel Technology, NC) Metal Oxide-silicon Semiconductor Field Effect Transistor detectors were placed at patient body surface; both entrance and exit side of the beam at patient head, neck, mediastinum, umbilicus, and knee to estimate midplane dose. When large differences (>10%) between the prescribed and measured dose were observed, dose delivery was corrected for subsequent fractions by the adjustment of couch speed and/or bolus placement. Under IRB exempt status, the authors retrospectively analyzed the treatment records of 161 patients who received TBI treatment between 2006 and 2011. Results: Across the entire cohort, the median {+-} SD (range) percent variance between calculated and measured dose for head, neck, mediastinum, umbilicus, and knee was -2.3 {+-} 10.2% (-66.2 to +35.3), 1.1 {+-} 11.5% (-62.2 to +40.3), -1.9 {+-} 9.5% (-66.4 to +46.6), -1.1 {+-} 7.2% (-35.2 to +42.9), and 3.4 {+-} 12.2% (-47.9 to +108.5), respectively. More than half of treatments were within {+-}10% of the prescribed dose for all anatomical regions. For 80% of treatments (10%-90%), dose at the umbilicus was within {+-}10

  9. Discriminative ability of total body bone-mineral measured by dual photon absorptiometry

    International Nuclear Information System (INIS)

    Gotfredsen, A.; Poedenphant, J.; Nilas, L.; Christiansen, C.

    1989-01-01

    We investigated the descriminative ability of total body bone-mineral expressed as the total body bone-density (TBBD) measured by dual photon absorptiometry (DPA) in 79 healthy premenopausal women, 27 healthy postmenopausal women, and 120 female osteoporotic fracture patients presenting with either Colles' fracture, vertebral fracture or femoral neck-fracture. TBBD was compared to the bone-mineral density of the lumbar spine (BMD spine ) also measured by DPA, and to the bone-mineral content of the forearms (BMC forearm ) measured by single photon absorptiometry (SPA). TBBD, BMD spine and BMC forearm showed that all the fracture patient groups had significantly reduced bone-mass. Using receiver operating characteristic (ROC) analysis, we found that TBBD had a tendency towards better discriminative ability than BMD spine or BMC forearm with regard to the discrimination between healthy premenopausal women and the three types of osteoporotic fractures. BMC forearm had an intermediate position, whereas BMD spine had the smallest discriminative ability. TBBD also discriminated better between healthy postmenopausal women and hip-fracture patients than BMD spine or BMC forearm , whereas there was no significant difference between the three methods regarding the discrimination between the healthy postmenopausal women and the Colles' and spinal fracture patients. We conclude that the TBBD measurement by DPA has a discriminative potential which is better than the local spine or forearm measurements. (author)

  10. Total body fat, proinflammatory cytokines and insulin resistance in Indian subjects

    International Nuclear Information System (INIS)

    Yajnik, C.S.; Lubree, H.G.; Rege, S.S.; Bhat, D.S.; Raut, K.N.; Panchanadikar, A.S.; Joglekar, C.B.; Naik, S.S.; Shetty, P.; Yudkin, J.; Kurpad, A.V.

    2002-01-01

    We studied cardiovascular risk factors in 30 to 50 year old Indian men in three geographical locations (rural, urban slums and urban middle class) in relation to their body fat. A total of 1,222 subjects, selected by stratified random sampling were screened: 39 reported diabetic or hypertensive. Of the remaining subjects 600 were randomly selected for further testing. This is a report 441 men studied (149 rural, 142 slums, 150 urban middle class). The mean age of these men was 38 y rural, 38 y urban slums, 41 y urban middle class, mean BMI 21.0 kg/m 2 , 22.3 kg/m 2 and 24.3 kg/m 2 respectively, mean body fat percent by bio-impedance 20.4%, 22.5% and 30.4% and by Deuterated water was 19.9%, 21.6% and 27.2% respectively. A 75 g oral glucose tolerance test (WHO 1985) showed no diabetes in rural subjects, while 4% urban slum dwellers and 10 in urban middle class were diabetic; 9% rural men had IGT, compared to 12% in urban slums and 20% in urban middle class. Hypertension (blood pressure ≥ 140/90 mm Bg) was present in 2% rural men, 4% in urban slums and in 10% men in urban middle class. Mean plasma cholesterol concentration was 148 mg% in rural, 53 mg% in urban slums and 64 mg% in urban middle class, mean plasma triglyceride concentrations were 82 mg%, 95 mg% and 108 mg% respectively. All cardiovascular risk factors were strongly related to measures of obesity (body fat % and waist hip ratio). On multivariate analysis 2h plasma glucose (OGTT) concentration and blood pressure were additionally related to geographical location (urban middle class>slums>rural). Our results suggest that urbanisation increases the risk of glucose intolerance and hypertension independent of the body fat percent or its central distribution. This suggests there may he additional environmental factors in the urban environment increasing the risk of diabetes over and above the effect of body fat. (author)

  11. Total body fat, proinflammatory cytokines and insulin resistance in Indian subjects

    Energy Technology Data Exchange (ETDEWEB)

    Yajnik, C S; Lubree, H G; Rege, S S; Bhat, D S; Raut, K N; Panchanadikar, A S; Joglekar, C B; Naik, S S [Diabetest Unit, KEM Hospital Resarch Centre, Pune (India); Shetty, P [London School of Hygiene and Tropical Medicine, London (United Kingdom); Yudkin, J [International Health and Medical Education Centre, UCL, London (United Kingdom); Kurpad, A V [St. John' s Medical College, Bangalore (India)

    2002-07-01

    We studied cardiovascular risk factors in 30 to 50 year old Indian men in three geographical locations (rural, urban slums and urban middle class) in relation to their body fat. A total of 1,222 subjects, selected by stratified random sampling were screened: 39 reported diabetic or hypertensive. Of the remaining subjects 600 were randomly selected for further testing. This is a report 441 men studied (149 rural, 142 slums, 150 urban middle class). The mean age of these men was 38 y rural, 38 y urban slums, 41 y urban middle class, mean BMI 21.0 kg/m{sup 2}, 22.3 kg/m{sup 2} and 24.3 kg/m{sup 2} respectively, mean body fat percent by bio-impedance 20.4%, 22.5% and 30.4% and by Deuterated water was 19.9%, 21.6% and 27.2% respectively. A 75 g oral glucose tolerance test (WHO 1985) showed no diabetes in rural subjects, while 4% urban slum dwellers and 10 in urban middle class were diabetic; 9% rural men had IGT, compared to 12% in urban slums and 20% in urban middle class. Hypertension (blood pressure {>=} 140/90 mm Bg) was present in 2% rural men, 4% in urban slums and in 10% men in urban middle class. Mean plasma cholesterol concentration was 148 mg% in rural, 53 mg% in urban slums and 64 mg% in urban middle class, mean plasma triglyceride concentrations were 82 mg%, 95 mg% and 108 mg% respectively. All cardiovascular risk factors were strongly related to measures of obesity (body fat % and waist hip ratio). On multivariate analysis 2h plasma glucose (OGTT) concentration and blood pressure were additionally related to geographical location (urban middle class>slums>rural). Our results suggest that urbanisation increases the risk of glucose intolerance and hypertension independent of the body fat percent or its central distribution. This suggests there may he additional environmental factors in the urban environment increasing the risk of diabetes over and above the effect of body fat. (author)

  12. Creatine Supplementation Increases Total Body Water in Soccer Players: a Deuterium Oxide Dilution Study.

    Science.gov (United States)

    Deminice, R; Rosa, F T; Pfrimer, K; Ferrioli, E; Jordao, A A; Freitas, E

    2016-02-01

    This study aimed to evaluate changes in total body water (TBW) in soccer athletes using a deuterium oxide dilution method and bioelectrical impedance (BIA) formulas after 7 days of creatine supplementation. In a double-blind controlled manner, 13 healthy (under-20) soccer players were divided randomly in 2 supplementation groups: Placebo (Pla, n=6) and creatine supplementation (CR, n=7). Before and after the supplementation period (0.3 g/kg/d during 7 days), TBW was determined by deuterium oxide dilution and BIA methods. 7 days of creatine supplementation lead to a large increase in TBW (2.3±1.0 L) determined by deuterium oxide dilution, and a small but significant increase in total body weight (1.0±0.4 kg) in Cr group compared to Pla. The Pla group did not experience any significant changes in TBW or body weight. Although 5 of 6 BIA equations were sensitive to determine TBW changes induced by creatine supplementation, the Kushner et al. 16 method presented the best concordance levels when compared to deuterium dilution method. In conclusion, 7-days of creatine supplementation increased TBW determined by deuterium oxide dilution or BIA formulas. BIA can be useful to determine TBW changes promoted by creatine supplementation in soccer athletes, with special concern for formula choice. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Bromide space, total body water, and sick cell syndrome

    International Nuclear Information System (INIS)

    Schober, O.; Hundeshagen, H.; Lehr, L.

    1982-01-01

    Displacements of the bromide space (Br-82-C, as a marker for the extracellular fluid compartment) are caused by an enhanced anatomical space and/or increased permeability of cells to bromide. The ratio Br-82-C: total body water (TBW) was evaluated to be 0.83 +- 0.17 in critically ill patients (n = 38) compared with the normal value of 0.46 +- 0.04 (n = 10). Because of normal TBW in critically ill patients (TBW = 505 +- 68 ml/kg), an increased bromide penetration into cells seems to be responsible for the enlarged ratio Br-82-C: TBW. Taking into consideration measurements in patients with malabsorption (Br-82-C: TBW = 0.56 +- 0.13; n = 13) and carcinoma of the rectum and colon (Br-82-C: TBW = 0.66 +- 0.24; n = 18) we think that the bromide space is a good measurement of the effective extracellular water. (orig.)

  14. Biocompatible and totally disintegrable semiconducting polymer for ultrathin and ultralightweight transient electronics.

    Science.gov (United States)

    Lei, Ting; Guan, Ming; Liu, Jia; Lin, Hung-Cheng; Pfattner, Raphael; Shaw, Leo; McGuire, Allister F; Huang, Tsung-Ching; Shao, Leilai; Cheng, Kwang-Ting; Tok, Jeffrey B-H; Bao, Zhenan

    2017-05-16

    Increasing performance demands and shorter use lifetimes of consumer electronics have resulted in the rapid growth of electronic waste. Currently, consumer electronics are typically made with nondecomposable, nonbiocompatible, and sometimes even toxic materials, leading to serious ecological challenges worldwide. Here, we report an example of totally disintegrable and biocompatible semiconducting polymers for thin-film transistors. The polymer consists of reversible imine bonds and building blocks that can be easily decomposed under mild acidic conditions. In addition, an ultrathin (800-nm) biodegradable cellulose substrate with high chemical and thermal stability is developed. Coupled with iron electrodes, we have successfully fabricated fully disintegrable and biocompatible polymer transistors. Furthermore, disintegrable and biocompatible pseudo-complementary metal-oxide-semiconductor (CMOS) flexible circuits are demonstrated. These flexible circuits are ultrathin (<1 μm) and ultralightweight (∼2 g/m 2 ) with low operating voltage (4 V), yielding potential applications of these disintegrable semiconducting polymers in low-cost, biocompatible, and ultralightweight transient electronics.

  15. Observation of total electron content and irregularities in electron density using GHz band radiowaves emitted from satellite

    International Nuclear Information System (INIS)

    Ogawa, Tadahiko; Fujita, Masaharu; Awaka, Jun.

    1978-01-01

    The experiments to investigate the influence of troposphere on millimeter and sub-millimeter wave propagation were carried out, using the engineering test satellite -- 2 (ETS-2) which became the Japanese first stationary satellite and carries the transmitter emitting beacon waves of 1.7, 11.5 and 34.5 GHz coherent each other. By these experiments, it was found that the waves of 1.7 and 11.5 GHz were affected by the ionosphere. The measurement of total electron content using GHz band waves was the first trial in the world, and is capable of grasping its change with higher accuracy than conventional methods. Scintillation of 1.7 GHz is mainly the phenomenon during night, and it was revealed that it has a peak at 22.30 local time and occurred through the radiowave scattering owing to the irregularities of the ionosphere. It is also suggested that some plasma instability is generated in the place where electron density gradient in the ionosphere is large, and the irregularities of fine scale are produced, assuming from GHz band scintillations at the time of magnetic storm. The relations among wave number spectrum, scintillation frequency spectrum and S4 index (statistical quantity to give estimate for scintillation amplitude) can be derived by the weak scattering theory (Simple scattering theory). As seen above, the diagnosis of plasma disturbances in the ionosphere is feasible by the simultaneous observations of total electron content and scintillation. (Wakatsuki, Y.)

  16. Hyperfractionated total body irradiation for T-depleted HLA identical bone marrow transplants

    International Nuclear Information System (INIS)

    Latini, P.; Checcaglini, F.; Maranzano, E.; Aristei, C.; Panizza, B.M.; Gobbi, G.; Raymondi, C.; Aversa, F.; Martelli, M.F.

    1988-01-01

    Twenty patients suffering from malignant hemopathies (mean age 31.7 years) were given hyperfractionated total body irradiation (TBI) as conditioning for T-depleted HLA identical allogeneic bone marrow transplantation. At an average of 12 months (range of 4.5-22 months) follow-up there were two cases of early death and two cases (11%) of rejection. There were no cases of acute or chronic graft versus host disease nor cases of interstitial pneumonitis. The average time for durable engraftment was 22 days. Disease-free survival at 12 months was 65%. To improve the results and further reduce the percent of rejection, the authors propose intensifying the immunosuppressive conditioning by increasing the cyclophosphamide dose and that of TBI so that a total dose of 1560 cGy is reached. 35 refs.; 1 figure

  17. Familial Melanoma Associated with Li-Fraumeni Syndrome and Atypical Mole Syndrome: Total-body Digital Photography, Dermoscopy and Confocal Microscopy.

    Science.gov (United States)

    Giavedoni, Priscila; Ririe, Marnie; Carrera, Cristina; Puig, Susana; Malvehy, Josep

    2017-06-09

    Li-Fraumeni syndrome (LFS) is a rare autosomal dominant disorder caused by a mutation in the p53 gene. Melanoma is considered to be a rare, controversial component of LFS. The aim of this study is to describe the utility of systematic screening for melanoma in patients with LFS and atypical mole syndrome. Two 28-year-old identical twin sisters with LFS and atypical moles were monitored by physical examination, total-body digital photography and dermoscopy be-tween 2006 and 2014. A total of 117, predominantly dark-brown, reticular naevi were identified on case 1 and 105 on case 2. Excisions were performed during the evaluation period of 1 in-situ melanoma and 3 basal cell carcinomas in case 1, and 1 in-situ melanoma and 1 early invasive melanoma in case 2. The remaining melanocytic lesions in both patients were stable during follow-up. The 3 melanomas were new atypical lesions detected with total-body photography and dermoscopy. In conclusion, monitoring LFS patients with total-body photography and dermoscopy may be useful to detect early melanoma.

  18. Longitudinal measurements of total body water and body composition in healthy volunteers by online breath deuterium measurement and other near-subject methods

    Czech Academy of Sciences Publication Activity Database

    Engel, B.; Španěl, Patrik; Smith, D.; Diskin, A. M.; Davis, S. J.

    2005-01-01

    Roč. 2, č. 3 (2005), s. 99-106 ISSN 1479-456X R&D Projects: GA ČR(CZ) GA203/00/0632 Institutional research plan: CEZ:AV0Z40400503 Keywords : total body water * deuterium isotope dilution * FA-MS * bio-impendance Subject RIV: CF - Physical ; Theoretical Chemistry

  19. Beacon satellite studies and modelling of total electron contents of the ionosphere

    International Nuclear Information System (INIS)

    Tyagi, T.R.

    1990-01-01

    An attempt is made to highlight some of the beacon satellite studies, particularly those relating to total electron content (TEC) and scintillations, with special attention to Indian subcontinent observations. The modelling of TEC is described. The scope of new experiments for specific problem is indicated. (author). 78 refs., 12 figs

  20. Compendium of Total Ionizing Dose and Displacement Damage for Candidate Spacecraft Electronics for NASA

    Science.gov (United States)

    Cochran, Donna J.; Boutte, Alvin J.; Chen, Dakai; Pellish, Jonathan A.; Ladbury, Raymond L.; Casey, Megan C.; Campola, Michael J.; Wilcox, Edward P.; Obryan, Martha V.; LaBel, Kenneth A.; hide

    2012-01-01

    Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear, and hybrid devices.

  1. Driver electronics design and control for a total artificial heart linear motor.

    Science.gov (United States)

    Unthan, Kristin; Cuenca-Navalon, Elena; Pelletier, Benedikt; Finocchiaro, Thomas; Steinseifer, Ulrich

    2018-01-27

    For any implantable device size and efficiency are critical properties. Thus, a linear motor for a Total Artificial Heart was optimized with focus on driver electronics and control strategies. Hardware requirements were defined from power supply and motor setup. Four full bridges were chosen for the power electronics. Shunt resistors were set up for current measurement. Unipolar and bipolar switching for power electronics control were compared regarding current ripple and power losses. Here, unipolar switching showed smaller current ripple and required less power to create the necessary motor forces. Based on calculations for minimal power losses Lorentz force was distributed to the actor's four coils. The distribution was determined as ratio of effective magnetic flux through each coil, which was captured by a force test rig. Static and dynamic measurements under physiological conditions analyzed interaction of control and hardware and all efficiencies were over 89%. In conclusion, the designed electronics, optimized control strategy and applied current distribution create the required motor force and perform optimal under physiological conditions. The developed driver electronics and control offer optimized size and efficiency for any implantable or portable device with multiple independent motor coils. Graphical Abstract ᅟ.

  2. Total body irradiation and marrow transplantation for acute leukaemia. The Royal Marsden Hospital experience

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, A; Barrett, A J; Powles, R L [Institute of Cancer Research, Sutton (UK). Surrey Branch; Royal Marsden Hospital, London (UK))

    1979-06-01

    The experience with total body irradiation at the Royal Marsden Hospital is described for an elective program of transplantation in patients with acute myeloid leukaemia (AML) in first remission. Dose rate appears to be a critical factor in the reduction of radiation-associated damage and careful monitoring of the actual dose distribution and dose received is mandatory.

  3. In vivo prompt gamma activation analysis facility for total body nitrogen and cadmium

    International Nuclear Information System (INIS)

    Munive, Marco; Solis, Jose; Revilla, Angel

    2008-01-01

    Full text: Prompt Neutron Activation Analysis (PGNAA) is a technique that could have medical applications, like determination of body's contents of protein and heavy metals in vivo. The in vivo PGNAA facility, contains a neutron source (Cf-252) with safety device, a compartment for animal irradiation, and a gamma rays detecting system based on the NaI(Tl) detector with an analytical software. The prompt gamma rays were emitted after 10 -15 s of the interaction, so they don't produce radioactive waste, and have a characteristics energy for each element, i.e. a strong peak at 2.24 MeV is observed for H. The facility has been used with laboratory mice. Water-filled phantom placed in the neutron beam was used to system calibration. Three study groups of 5 mice each one were selected and were feed with a different diet and the total body nitrogen (TBN) of the mice was monitored with the facility. The diet produced a different TBN for each group. Some mice drunk diluted water with Cl 2 Cd, so the presence of Cd was detected in the mouse. The minimum Cd concentration that the system can detect was 20 ppm. The total dose (neutron and gamma dose was measured from TLDs and simulated by MNCP-4B in the sample compartment during the irradiation time (5 minutes) is less than 2.5 mSv. This total dose is low than the dose from other analytical radiological techniques (25 a 50 mSv). (author)

  4. Fractionated total body irradiation and autologous bone marrow transplantation in dogs: Hemopoietic recovery after various marrow cell doses

    International Nuclear Information System (INIS)

    Bodenburger, U.; Kolb, H.J.; Thierfelder, S.; Netzel, B.; Schaeffer, E.; Kolb, H.

    1980-01-01

    Hemopoietic recovery was studied in dogs given 2400 R fractionated total body irradiation within one week and graded doses of cryopreserved autologous bone marrow. Complete hemopoietic recovery including histology was observed after this dose and sufficient doses of marrow cells. Doses of more than 5.5 x 10 7 mononuclear marrow cells/kg body weight were sufficient for complete recovery in all dogs, 1.5 to 5.5 x 10 7 cells/kg were effective in some of the dogs and less than 1.5 x 10 7 cells/kg were insufficient for complete recovery. Similarly, more than 30000 CFUsub(c)/kg body weight were required for hemopoietic recovery. The optimal marrow cell dose which has been defined as the minimal dose required for the earliest possible recovery of leukocyte and platelet counts was 7-8 x 10 7 mononuclear marrow cells/kg body weight. It has been concluded that fractionated total body irradiation with 2400 R dose not require greater doses of marrow cells for hemopoietic reconstitution than lower single doses and that the hemopoietic microenvironment is not persistently disturbed after this dose. (author)

  5. Indication of total body irradiation in adult allogeneic bone marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Kasai, Masaharu (Sapporo Hokuyu Hospital (Japan). Artificial Organ and Transplantation Hospital)

    1992-10-01

    Indication of total body irradiation (TBI) in adult allogeneic bone marrow transplantation was discussed in comparison with non-TBI method of busulfan and cyclophosphamide (BU+CY). Each method has unique advantages and disadvantages. Concerning adverse effects of interstitial pneumonia, liver dysfunction and so on, there are no significant differences in both methods. TBI method should be preferably indicated for lymphatic leukemias and leukemias involving central nervous systems. It is important to clarify what kinds of combination regimen depending on the type and the stage of disease are most suitable for the longer survival of patients with leukemia or aplastic anemia by multicentric randomized study. (author).

  6. Thermodynamics of the living organisms. Allometric relationship between the total metabolic energy, chemical energy and body temperature in mammals

    Science.gov (United States)

    Atanasov, Atanas Todorov

    2017-11-01

    The study present relationship between the total metabolic energy (ETME(c), J) derived as a function of body chemical energy (Gchem, J) and absolute temperature (Tb, K) in mammals: ETME(c) =Gchem (Tb/Tn). In formula the temperature Tn =2.73K appears normalization temperature. The calculated total metabolic energy ETME(c) differs negligible from the total metabolic energy ETME(J), received as a product between the basal metabolic rate (Pm, J/s) and the lifespan (Tls, s) of mammals: ETME = Pm×Tls. The physical nature and biological mean of the normalization temperature (Tn, K) is unclear. It is made the hypothesis that the kTn energy (where k= 1.3806×10-23 J/K -Boltzmann constant) presents energy of excitation states (modes) in biomolecules and body structures that could be in equilibrium with chemical energy accumulated in body. This means that the accumulated chemical energy allows trough all body molecules and structures to propagate excitations states with kTn energy with wavelength in the rage of width of biological membranes. The accumulated in biomolecules chemical energy maintains spread of the excited states through biomolecules without loss of energy.

  7. Total and elastic electron scattering cross sections from Xe at intermediate and high energies

    International Nuclear Information System (INIS)

    Garcia, G; Pablos, J L de; Blanco, F; Williart, A

    2002-01-01

    Experimental total electron scattering cross sections from Xe in the energy range 300-5000 eV have been obtained with experimental errors of about 3%. The method was based on the measurement of the attenuation of a linear electron beam through a Xe gas cell in combination with an electron spectroscopy technique to analyse the energy of the transmitted electrons. Differential and integral elastic cross sections have been calculated using a scattering potential method which includes relativistic effects. The consistency of our theoretical and experimental results is also discussed in the paper. Finally, analytical formulae depending on two parameters, namely the number of target electrons and the atomic polarizability, are given to reproduce the experimental data for Ne, Ar, Kr and Xe in the energy range 500-10 000 eV

  8. Immediate total-body CT scanning versus conventional imaging and selective CT scanning in patients with severe trauma (REACT-2): a randomised controlled trial.

    Science.gov (United States)

    Sierink, Joanne C; Treskes, Kaij; Edwards, Michael J R; Beuker, Benn J A; den Hartog, Dennis; Hohmann, Joachim; Dijkgraaf, Marcel G W; Luitse, Jan S K; Beenen, Ludo F M; Hollmann, Markus W; Goslings, J Carel

    2016-08-13

    Published work suggests a survival benefit for patients with trauma who undergo total-body CT scanning during the initial trauma assessment; however, level 1 evidence is absent. We aimed to assess the effect of total-body CT scanning compared with the standard work-up on in-hospital mortality in patients with trauma. We undertook an international, multicentre, randomised controlled trial at four hospitals in the Netherlands and one in Switzerland. Patients aged 18 years or older with trauma with compromised vital parameters, clinical suspicion of life-threatening injuries, or severe injury were randomly assigned (1:1) by ALEA randomisation to immediate total-body CT scanning or to a standard work-up with conventional imaging supplemented with selective CT scanning. Neither doctors nor patients were masked to treatment allocation. The primary endpoint was in-hospital mortality, analysed in the intention-to-treat population and in subgroups of patients with polytrauma and those with traumatic brain injury. The χ(2) test was used to assess differences in mortality. This trial is registered with ClinicalTrials.gov, number NCT01523626. Between April 22, 2011, and Jan 1, 2014, 5475 patients were assessed for eligibility, 1403 of whom were randomly assigned: 702 to immediate total-body CT scanning and 701 to the standard work-up. 541 patients in the immediate total-body CT scanning group and 542 in the standard work-up group were included in the primary analysis. In-hospital mortality did not differ between groups (total-body CT 86 [16%] of 541 vs standard work-up 85 [16%] of 542; p=0.92). In-hospital mortality also did not differ between groups in subgroup analyses in patients with polytrauma (total-body CT 81 [22%] of 362 vs standard work-up 82 [25%] of 331; p=0.46) and traumatic brain injury (68 [38%] of 178 vs 66 [44%] of 151; p=0.31). Three serious adverse events were reported in patients in the total-body CT group (1%), one in the standard work-up group (<1%), and

  9. Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy X-ray absorptiometry during prolonged weight loss

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Højgaard, L

    1996-01-01

    A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK). These measu......A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK......). These measurements were compared with bioimpedance analysis (BIA) by applying 11 predictive BIA equations published in the literature. Predictive equations for the present study population were developed, with the use of fat-free mass (FFM) as assessed by TBK and DXA as references in multiple regression analysis....... The results of the BIA equations varied widely; FFM was generally overestimated by BIA as compared with DXA and TBK before and after weight loss. During weight loss, the FFM did not change, as estimated by DXA (1.3 +/- 2.3 kg, p > 0.05) and TBK (0.9 +/- 2.9 kg, p > 0.05). The recorded change in impedance (R...

  10. Detection and Classification of Human Body Odor Using an Electronic Nose

    Directory of Open Access Journals (Sweden)

    Teerakiat Kerdcharoen

    2009-09-01

    Full Text Available An electronic nose (E-nose has been designed and equipped with software that can detect and classify human armpit body odor. An array of metal oxide sensors was used for detecting volatile organic compounds. The measurement circuit employs a voltage divider resistor to measure the sensitivity of each sensor. This E-nose was controlled by in-house developed software through a portable USB data acquisition card with a principle component analysis (PCA algorithm implemented for pattern recognition and classification. Because gas sensor sensitivity in the detection of armpit odor samples is affected by humidity, we propose a new method and algorithms combining hardware/software for the correction of the humidity noise. After the humidity correction, the E-nose showed the capability of detecting human body odor and distinguishing the body odors from two persons in a relative manner. The E-nose is still able to recognize people, even after application of deodorant. In conclusion, this is the first report of the application of an E-nose for armpit odor recognition.

  11. Detection and classification of human body odor using an electronic nose.

    Science.gov (United States)

    Wongchoosuk, Chatchawal; Lutz, Mario; Kerdcharoen, Teerakiat

    2009-01-01

    An electronic nose (E-nose) has been designed and equipped with software that can detect and classify human armpit body odor. An array of metal oxide sensors was used for detecting volatile organic compounds. The measurement circuit employs a voltage divider resistor to measure the sensitivity of each sensor. This E-nose was controlled by in-house developed software through a portable USB data acquisition card with a principle component analysis (PCA) algorithm implemented for pattern recognition and classification. Because gas sensor sensitivity in the detection of armpit odor samples is affected by humidity, we propose a new method and algorithms combining hardware/software for the correction of the humidity noise. After the humidity correction, the E-nose showed the capability of detecting human body odor and distinguishing the body odors from two persons in a relative manner. The E-nose is still able to recognize people, even after application of deodorant. In conclusion, this is the first report of the application of an E-nose for armpit odor recognition.

  12. Prediction of total electron content using the international reference ionosphere

    International Nuclear Information System (INIS)

    Mcnamara, L.F.

    1984-01-01

    It is pointed out that the International Reference Ionosphere (IRI) is an empirical model of the ionosphere based on experimental observations. Rawer et al. (1978) have discussed the goals and status of the IRI. The aim of the IRI is related to the establishment of a compendium of height profiles through the ionosphere for the four main parameters, taking into account plasma density, temperature of ions and electrons, and ion composition. The present model is inadequate in some areas, and the IRI working group has encouraged tests of the model's validity. The present investigation is concerned with a test of the model's ability to reproduce observations of total electron content (TEC) over a wide range of conditions. The TEC observations were obtained with the aid of the Faraday rotation technique, which provides the TEC out to about 2000 km. Tests using the Bent ionospheric model indicate that the altitude range 1000 to 2000 km contributes up to five percent of the TEC. 12 references

  13. The relationships among total body fat, bone mineral content and bone marrow adipose tissue in early-pubertal girls.

    Science.gov (United States)

    L Newton, Anna; J Hanks, Lynae; Davis, Michelle; Casazza, Krista

    2013-01-01

    Investigation of the physiologic relevance of bone marrow adipose tissue (BMAT) during growth may promote understanding of the bone-fat axis and confluence with metabolic factors. The objective of this pilot investigation was two-fold: (1) to evaluate the relationships among total body fat, bone mineral content (BMC) and femoral BMAT during childhood and underlying metabolic determinants and (2) to determine if the relationships differ by race. Participants included white and non-Hispanic black girls (n=59) ages 4-10 years. Femoral BMAT volume was measured by magnetic resonance imaging, BMC and body fat by dual-energy X-ray absorptiometry. Metabolic parameters were assessed in the fasted state. Total fat and BMC were positively associated with BMAT; however, simultaneous inclusion of BMC and body fat in the statistical model attenuated the association between BMC and BMAT. Differences in BMAT volume were observed, non-Hispanic black girls exhibiting marginally greater BMAT at age eight (P=0.05) and white girls exhibiting greater BMAT at age ten (PBMAT and leptin (P=0.02) and adiponectin (P=0.002) in white girls while BMAT and insulin were inversely related in non-Hispanic black girls (P=0.008). Our findings revealed a positive relationship between BMAT, body fat and BMC, although body fat, respective to leptin, contributed partly to the relationship between BMAT and BMC. Despite large differences in total fat between non-Hispanic black and white, the relationship between BMAT and BMC was similar to white girls. However, this relationship appeared to be impacted through different mechanisms according to race.

  14. Treatment verification and in vivo dosimetry for total body irradiation using thermoluminescent and semiconductor detectors

    International Nuclear Information System (INIS)

    Oliveira, F.F.; Amaral, L.L.; Costa, A.M.; Netto, T.G.

    2014-01-01

    The objective of this work is the characterization of thermoluminescent and semiconductor detectors and their applications in treatment verification and in vivo dosimetry for total body irradiation (TBI) technique. Dose measurements of TBI treatment simulation performed with thermoluminescent detectors inserted in the holes of a “Rando anthropomorphic phantom” showed agreement with the prescribed dose. For regions of the upper and lower chest where thermoluminescent detectors received higher doses it was recommended the use of compensating dose in clinic. The results of in vivo entrance dose measurements for three patients are presented. The maximum percentual deviation between the measurements and the prescribed dose was 3.6%, which is consistent with the action level recommended by the International Commission on Radiation Units and Measurements (ICRU), i.e., ±5%. The present work to test the applicability of a thermoluminescent dosimetric system and of a semiconductor dosimetric system for performing treatment verification and in vivo dose measurements in TBI techniques demonstrated the value of these methods and the applicability as a part of a quality assurance program in TBI treatments. - Highlights: • Characterization of a semiconductor dosimetric system. • Characterization of a thermoluminescent dosimetric system. • Application of the TLDs for treatment verification in total body irradiation treatments. • Application of semiconductor detectors for in vivo dosimetry in total body irradiation treatments. • Implementation of in vivo dosimetry as a part of a quality assurance program in radiotherapy

  15. Biochemical and hematological indicators in model of total body irradiation

    International Nuclear Information System (INIS)

    Dubner, D; Gisone, P.; Perez, M.R.; Barboza, M.; Luchetta, P.; Longoni, H.; Sorrentino, M.; Robison, A.

    1998-01-01

    With the purpose of evaluating the applicability of several biological indicators in accidental overexposures a study was carried out in 20 patients undergoing therapeutical total body irradiation (TBI). The following parameters were evaluated: a) Oxidative stress indicators: erythrocyte superoxide dismutase (SOD) and catalase activity (CAT), lipo peroxyde levels (TBARS) and total plasma antioxidant activity (TAA). b) Haematological indicators: reticulocyte maturity index (RMI) and charges in lymphocyte subpopulations. Non significant changes in SOD and CAT activity were observed. Significant higher TBARS levels were found in patients with unfavorable post-BTM course without any significant correlation with TAA. RMI decreased early and dropped to zero in most of the patients and rose several days prior to reticulocyte, neutrophils and platelets counts. A significant decrease in absolute counts of all lymphocyte subpopulations was observed during TBI, particularly for B lymphocytes. A subpopulation of natural killer (NK) cells (CD16+/ CD 56 +) showed a relative higher radioresistance. Cytotoxic activity was significantly decreased after TBI. These data suggest that TBARS could provide an useful evolutive indicator in accidental over exposure d patients and RMI is an early indicator of bone marrow recovery after radioinduced aplasia. The implications of the different radiosensitivities within the NK subsets remains unanswered. (author) [es

  16. Electron-helium S-wave model benchmark calculations. I. Single ionization and single excitation

    Science.gov (United States)

    Bartlett, Philip L.; Stelbovics, Andris T.

    2010-02-01

    A full four-body implementation of the propagating exterior complex scaling (PECS) method [J. Phys. B 37, L69 (2004)] is developed and applied to the electron-impact of helium in an S-wave model. Time-independent solutions to the Schrödinger equation are found numerically in coordinate space over a wide range of energies and used to evaluate total and differential cross sections for a complete set of three- and four-body processes with benchmark precision. With this model we demonstrate the suitability of the PECS method for the complete solution of the full electron-helium system. Here we detail the theoretical and computational development of the four-body PECS method and present results for three-body channels: single excitation and single ionization. Four-body cross sections are presented in the sequel to this article [Phys. Rev. A 81, 022716 (2010)]. The calculations reveal structure in the total and energy-differential single-ionization cross sections for excited-state targets that is due to interference from autoionization channels and is evident over a wide range of incident electron energies.

  17. Fetal liver transplantation in 2 patients with acute leukaemia after total body irradiation

    International Nuclear Information System (INIS)

    Lucarelli, G.; Izzi, T.; Porcellini, A.; Delfini, C.; Galimberti, M.; Moretti, L.; Polchi, P.; Agostinelli, F.; Andreani, M.; Manna, M.; Dallapiccola, B.

    1982-01-01

    2 patients with acute leukaemia in relapse were transplanted with fetal liver cells following a conditioning regimen of cyclophosphamide (120 mg/kg) and total body irradiation (1000 r). Each patient achieved a remission with haematopoietic recovery that was rapid in one case and delayed in the other. In one case there was evidence of chimerism as demonstrated by the presence of the XYY karyotype of the donor fetus in 20 % of marrow metaphases, by the presence of double Y bodies in the peripheral blood, by the appearance of new HLA-antigens, and by red cell isoenzyme phenotypes of donor origin. In the second case there was prompt haemotopoietic recovery and the appearance of red cell isoenzyme phenotypes of donor origin. Survival was 153 and 30 d, respectively, and both patients died of interstitial pneumonia without evidence of graft versus host disease. (author)

  18. Evaluation and comparison of gamma- and electron beam irradiation effects on total and free gossypol of cottonseed meal

    International Nuclear Information System (INIS)

    Shawrang, P.; Mansouri, M.H.; Sadeghi, A.A.; Ziaie, F.

    2011-01-01

    Impact of gamma- and electron beam irradiation on total and free gossypol content of cottonseed meal was assessed by exposing them to doses of 10, 15, 20, 25 and 30 kGy. Gamma rays and electron beam showed the same effects with significant dose-dependent decrease in total and free gossypol content. Based on these results, ionizing irradiation at doses of 25 kGy and above could completely remove free gossypol and bring down total gossypol content to permissible level in poultry feed.

  19. Cross-sex hormone therapy in transgender persons affects total body weight, body fat and lean body mass: a meta-analysis.

    Science.gov (United States)

    Klaver, M; Dekker, M J H J; de Mutsert, R; Twisk, J W R; den Heijer, M

    2017-06-01

    Weight gain and body fat increase the risk of cardiometabolic disease. Cross-sex hormone therapy in transgender persons leads to changes in body weight and body composition, but it is unclear to what extent. We performed a meta-analysis to investigate the changes in body weight, body fat and lean body mass during cross-sex hormone therapy in transgender persons. We searched the PubMed database for eligible studies until November 2015. Ten studies reporting changes in body weight, body fat or lean mass in hormone naive transgender persons were included, examining 171 male-to-female and 354 female-to-male transgender people. Pooled effect estimates in the male-to-female group were +1.8 kg (95% CI: 0.2;3.4) for body weight, +3.0 kg (2.0;3.9) for body fat and -2.4 kg (-2.8; -2.1) for lean body mass. In the female-to-male group, body weight changed with +1.7 kg (0.7;2.7), body fat with -2.6 kg (-3.9; -1.4) and lean body mass with +3.9 kg (3.2;4.5). Cross-sex hormone therapy increases body weight in both sexes. In the male-to-female group, a gain in body fat and a decline in lean body mass are observed, while the opposite effects are seen in the female-to-male group. Possibly, these changes increase the risk of cardiometabolic disease in the male-to-female group. © 2016 Blackwell Verlag GmbH.

  20. Radiobiological considerations in the treatment of neuroblastoma by total body irradiation

    International Nuclear Information System (INIS)

    Wheldon, T.E.; O'Donoghue, J.; Gregor, A.; Livingstone, A.; Wilson, L.; West of Scotland Health Boards, Glasgow

    1986-01-01

    Neuroblastoma is a radiosensitive neoplasm for which total body irradiation (TBI) is presently under clinical consideration. Collated data on the radiobiology of human neuroblastoma cells in vitro indicates moderate cellular radiosensitivity and low capacity for accumulation of sublethal damage. Mathematical studies incorporating these parameters suggest that low dose fractionated TBI is unlikely to achieve significant levels of tumour cell kill. When high dose TBI is used in conjuction with bone marrow rescue a tumour 'log cell kill' of 4-5 should be achievable. This effect would be additional to that acheived by chemotherapy. Fractionated TBI with bone marrow rescue may be curative for some patients in clinical remission who are presently destined to relapse. (Auth.)

  1. Inability of donor total body irradiation to prolong survival of vascularized bone allografts: Experimental study in the rat

    International Nuclear Information System (INIS)

    Gonzalez del Pino, J.; Benito, M.; Randolph, M.A.; Weiland, A.J.

    1990-01-01

    At the present time, the toxic side effects of recipient immunosuppression cannot be justified for human non-vital organ transplantation. Total body irradiation has proven effective in ablating various bone-marrow-derived and endothelial immunocompetent cellular populations, which are responsible for immune rejection against donor tissues. Irradiation at a dose of 10 Gy was given to donor rats six days prior to heterotopic transplantation of vascularized bone allografts to host animals. Another group of recipient rats also received a short-term (sixth to fourteenth day after grafting), low dose of cyclosporine. Total body irradiation was able merely to delay rejection of grafts across a strong histocompatibility barrier for one to two weeks, when compared to nonirradiated allografts. The combination of donor irradiation plus cyclosporine did not delay the immune response, and the rejection score was similar to that observed for control allografts. Consequently, allograft viability was quickly impaired, leading to irreversible bone damage. This study suggest that 10 Gy of donor total body irradiation delivered six days prior to grafting cannot circumvent the immune rejection in a vascularized allograft of bone across a strong histocompatibility barrier

  2. The effect of whole body or total-head x irradiation of the metallophilic cells in the mice spleen

    International Nuclear Information System (INIS)

    Sasaki, Osamu; Matsueda, Yasutoshi; Mizuguchi, Hiroshi; Moriguchi, Kenzo; Ogata, Kunitoshi; Sugie, Tsuneto

    1984-01-01

    The purpose of this paper is to clarify morphological changes of the reticuloendothelial cells in the spleen following X-irradiation by Katsura's silver impregnation method. The animals used in this experiment were ddN female mice weighing 20 to 25g. The mice were given X-irradiation to the total-head (1,500R) or whole body (300R). The metallophilic cells in the spleen of control mice were of the small foamy type in the follicle, the large stellate type in the marginal metallophils, the small branching type in the marginal zone and the small foamy or round type in the red pulp, respectively. The metallophilic cells decreased immediately after whole body irradiation and the number of cells returned to normal in from 10 to 14 days. On the other hand, the number of the metallophilic cells in the follicle and the perifollicular region increased immediately after total-head X-irradiation. This state continued for several days. In the marginal zone and red pulp, the number of amoebian type cells appeared from 24 hours after irradiation and the number of cells in total-head irradiation group were more clearly distinguishable than in the whole body irradiated group. (author)

  3. Estimation of the dose distribution within, and total dose to, the body of an acutely overexposed person

    International Nuclear Information System (INIS)

    Beer, G.P. de; Feather, J.I.; Oude, A. de; Language, A.E.

    1981-01-01

    In a case of accidental overexposure of a person, it is important to obtain a reliable value of the whole body dose as well as of the dose distribution within the body. Any follow-up treatment based only on the clinical effects as and when they appear, may result in insufficient or even erroneous therapy. In this respect knowledge of total dose and its distribution within the body may be a valuable aid in deciding on the follow-up treatment, taking into account the latent nature of the clinical effects. The calculated whole body dose and its distribution within the body of a person overexposed to a 192 Ir radiography source, are compared to experimentally determined values. In both cases the calculated values prove to be of sufficient accuracy to serve as an aid in decisions on the follow-up treatment. (author)

  4. Total and Segmental Body Composition Examination in Collegiate Football Players Using Multifrequency Bioelectrical Impedance Analysis and Dual X-ray Absorptiometry.

    Science.gov (United States)

    Raymond, Christiana J; Dengel, Donald R; Bosch, Tyler A

    2018-03-01

    Raymond, CJ, Dengel, DR, and Bosch, TA. Total and segmental body composition examination in collegiate football players using multifrequency bioelectrical impedance analysis and dual X-ray absorptiometry. J Strength Cond Res 32(3): 772-782, 2018-The current study examined the influence of player position on the agreement between multifrequency bioelectrical impedance analysis (MfBIA) and dual X-ray absorptiometry (DXA) when assessing total and segmental percent body fat (BF%), fat mass (FM), and fat-free mass (FFM) in National Collegiate Athletic Association Division I collegiate football athletes. Forty-four male collegiate athletes (age = 19 ± 1 year; height = 1.9 ± 1.0 m; and body mass = 106.4 ± 18.8 kg) participated. Player positions included: offensive linemen (OL; n = 7), tight ends (TE; n = 4), wide receivers (WR; n = 9), defensive linemen (DL; n = 6), defensive backs (DB; n = 8), linebackers (LB; n = 6), and running backs (RB; n = 4). Total and segmental body composition measured using MfBIA were compared with values obtained using DXA. Compared with DXA, MfBIA underestimated BF% (3.0 ± 3.8%), total FM (2.5 ± 4.3 kg), arm FM (0.4 ± 0.8 kg), arm FFM (1.4 ± 0.9 kg), leg FM (2.8 ± 2.0 kg), and leg FFM (5.4 ± 2.4 kg) (all p FFM (-2.4 ± 4.5 kg) (p FFM), ±3.83 kg (leg FM), ±4.62 kg (leg FFM), and ±8.83 kg (total FFM). No significant differences were observed between devices for trunk FM (-0.3 ± 3.0 kg; p = 0.565) and trunk FFM (0.4 ± 2.4 kg; p = 0.278), with LOAs of ±5.92 and ±4.69 kg, respectively. Player position significantly affected all between-device mean body composition measurement differences (adjusted p ≤ 0.05), with OL demonstrating the greatest effect on each variable. Therefore, MfBIA does not seem accurate in examining between-player body composition in college football players.

  5. A Common Allele in FGF21 Associated with Sugar Intake Is Associated with Body Shape, Lower Total Body-Fat Percentage, and Higher Blood Pressure

    Directory of Open Access Journals (Sweden)

    Timothy M. Frayling

    2018-04-01

    Full Text Available Summary: Fibroblast growth factor 21 (FGF21 is a hormone that has insulin-sensitizing properties. Some trials of FGF21 analogs show weight loss and lipid-lowering effects. Recent studies have shown that a common allele in the FGF21 gene alters the balance of macronutrients consumed, but there was little evidence of an effect on metabolic traits. We studied a common FGF21 allele (A:rs838133 in 451,099 people from the UK Biobank study, aiming to use the human allele to inform potential adverse and beneficial effects of targeting FGF21. We replicated the association between the A allele and higher percentage carbohydrate intake. We then showed that this allele is more strongly associated with higher blood pressure and waist-hip ratio, despite an association with lower total body-fat percentage, than it is with BMI or type 2 diabetes. These human phenotypes of variation in the FGF21 gene will inform research into FGF21’s mechanisms and therapeutic potential. : Drugs targeting the hormone FGF21 may have beneficial health effects. Variations in human DNA in the FGF21 gene provide an indication of what those effects may be. Here, we show that variation in the FGF21 gene is associated with higher blood pressure and altered body shape, despite lower total body-fat percentage. Keywords: FGF21, BMI, waist-hip ratio, blood pressure, body fat, allele, genetic variant, UK Biobank

  6. Incidence of interstitial pneumonia after hyperfractionated total body irradiation before autologous bone marrow/stem cell transplantation

    International Nuclear Information System (INIS)

    Lohr, F.; Schraube, P.; Wenz, F.; Flentje, M.; Kalle, K. von; Haas, R.; Hunstein, W.; Wannenmacher, M.

    1995-01-01

    Purpose/Objectives Interstitial pneumonia (IP) is a severe complication after allogenic bone marrow transplantation (BMT) with incidence rates between 10 % and 40 % in different series. It is a polyetiologic disease that occurs depending on age, graft vs. host disease (GvHD), CMV-status, total body irradiation (TBI) and immunosuppressive therapy after BMT. The effects of fractionation and dose rate are not entirely clear. This study evaluates the incidence of lethal IP after hyperfractionated TBI for autologous BMT or stem cell transplantation. Materials and Methods Between 1982 and 1992, 182 patients (60 % male, 40 % female) were treated with hyperfractionated total body irradiation (TBI) before autologous bone marrow transplantation. Main indications were leukemias and lymphomas (53 % AML, 21 % ALL, 22 % NHL, 4 % others) Median age was 30 ys (15 - 55 ys). A total dose of 14.4 Gy was applied using lung blocks (12 fractions of 1.2 Gy in 4 days, dose rate 7-18 cGy/min, lung dose 9 - 9.5 Gy). TBI was followed by cyclophosphamide (200 mg/kg). 72 % were treated with bone marrow transplantation, 28 % were treated with stem cell transplantation. Interstitial pneumonia was diagnosed clinically, radiologically and by autopsy. Results 4 patients died most likely of interstitial pneumonia. For another 12 patients interstitial pneumonia was not the most likely cause of death but could not be excluded. Thus, the incidence of lethal IP was at least 2.2 % but certainly below 8.8 %. Conclusion Lethal interstitial pneumonia is a rare complication after total body irradiation before autologous bone marrow transplantation in this large, homogeously treated series. In the autologous setting, total doses of 14.4 Gy can be applied with a low risk for developing interstitial pneumonia if hyperfractionation and lung blocks are used. This falls in line with data from series with identical twins or t-cell depleted marrow and smaller, less homogeneous autologous transplant studies. Thus

  7. Top layer's thickness dependence on total electron-yield X-ray standing-wave

    International Nuclear Information System (INIS)

    Ejima, Takeo; Yamazaki, Atsushi; Banse, Takanori; Hatano, Tadashi

    2005-01-01

    A Mo single-layer film with a stepwise thickness distribution was fabricated on the same Mo/Si reflection multilayer film. Total electron-yield X-ray standing-wave (TEY-XSW) spectra of the aperiodic multilayer were measured with reflection spectra. The peak positions of the standing waves in the TEY-XSW spectra changed as the film thickness of the top Mo-layer increased

  8. Effect of dietary protein quality on the resistance of rats to total body radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bounous, G.; Pageau, R.

    1983-02-01

    Young rats have been fed four defined-formula diets before and after ..gamma..-irradiation (700 rd (7.0 Gy), 75 rd/min (750 mGy), 80 cm from the source, total body). Animals eating a diet containing lactalbumin hydrolyzate (20 g/100 g diet) exhibited less anorexia and weight loss following ..gamma..-rays than a corresponding group eating casein hydrolyzate (20 g/100 g diet).

  9. Use of the cellular model of body composition to describe changes in body water compartments after total fasting, very low calorie diet and low calorie diet in obese men.

    Science.gov (United States)

    Siervo, M; Faber, P; Gibney, E R; Lobley, G E; Elia, M; Stubbs, R J; Johnstone, A M

    2010-05-01

    The cellular model of body composition divides the body in body cell mass (BCM), extracellular solids and extracellular fluids. This model has been infrequently applied for the evaluation of weight loss (WL) programmes. (1) To assess changes in body compartments in obese men undergoing fasting, very low calorie diet (VLCD) and low calorie diet (LCD); (2) to evaluate two cellular models for the determination of changes in BCM, fat mass (FM) and body fluids. Three groups of six, obese men participated in a total fast (F) for 6 days, a VLCD (2.5 MJ per day) for 3 weeks or an LCD (5.2 MJ per day) for 6 weeks. Body composition was measured at baseline and after small ( approximately 5%) and moderate ( approximately 10%) WL. FM was measured using a four-compartment model. Total body water (TBW) and extracellular water (ECW) were, respectively, measured by deuterium and sodium bromide dilution and intracellular water (ICW) calculated by difference. Two cellular models were used to measure BCM, FM and body fluids distribution. After about 5%WL changes in TBW were F=-3.2+/-1.2 kg (Pfasting (+1.5+/-3.1 kg, n.s.), decreased during the VLCD (-2.0+/-1.5 kg, Pfasting (-4.7+/-3.9 kg, Pfasting group and it was directly associated with changes in ICW. After a 6-day period of fasting we observed more ICW losses and less fat mobilization compared with VLCD and LCD. The cellular model of body composition is suitable for the characterization of changes in body fluids distribution during WL.

  10. An Acute Transverse Myelitis Attack after Total Body Irradiation: A Rare Case

    Directory of Open Access Journals (Sweden)

    Muzaffer Keklik

    2013-01-01

    Full Text Available Total body irradiation (TBI combined with chemotherapy is widely used as a pretreatment regimen of bone marrow transplantation (BMT in hematologic disorders. Late complications related to TBI as part of the conditioning regimen for hematopoietic stem cell transplantation have been revealed. Acute transverse myelitis (ATM is a neurological syndrome characterized by disorder of motor, sensorial, and autonomic nerves, and tracts at medulla spinalis, which is resulted from involvement of spinal cord. In this paper, we presented an ATM attack developed after TBI in a patient with acute lymphoblastic leukemia (ALL as it is a rarely seen case.

  11. Total-body irradiation and bone-marrow transplantation - first observations on clinical tolerance

    International Nuclear Information System (INIS)

    Gocheva, L.; Sergieva, K.; Koleva, I.; Mlachkova, D.; Michailov, G.; Avramova, B.

    2004-01-01

    About 50 000 bone-marrow transplantations (BMT) are performed annually at the present stage in numerous clinical centers all over the world. The Bulgarian experience in total-body irradiation (TBI) with following BMT is rather scarce. The routine TBI procedures in the oncological practice in the country date back just to 2001. The aim of the present publication is to describe the Bulgarian experience and the first impressions from the clinical tolerance of the total-body irradiation (TBI) with subsequent allogeneic peripheral stem cell transplantation (PSCT). Patient characteristics are presented in detail, including their distribution with respect to sex, age, primary diagnose, recurrence number till BMT, patient status during BMT performance (clinical hematological remission or relapse), as well as the basic parameters of the conditioning regime including TBI with subsequent allogeneic PSCT. The position of the patient and the applied radiotherapeutic equipment are described as well as the TBI schemes, respectively 5 fractions of 2 Gy per day for two patients and 3-day irradiation with 6 fractions (two fractions with a 6-hour interval between them) for the rest of the patients. The total dose (TD) of 10 Gy is realized for all patients. The clinical tolerance of 7 patients subjected to TBI and allogeneic PSCT is discussed. All patients were tolerable to the TBI treatment and had no serious problems. The radiotherapy was interrupted only in the case of the first two patients due to slight gastro-intestinal reactions. The first days of radiation were accompanied with a light degree of headache, nausea and vomiting, which were successfully overcome by granisetron. Diarrhea syndrome and mucositis to the II-III degree were developed subsequently without parotitis development. On the days 0 and +1 of the clinical protocol transplantation was realized of non- T-cell-depleted grafts (in 5 patients) and T-cell-depleted grafts (in 2 patients), which had no serious

  12. Physically-based biodosimetry using in vivo EPR of teeth in patients undergoing total body irradiation

    Science.gov (United States)

    Williams, Benjamin B.; Dong, Ruhong; Nicolalde, Roberto J.; Matthews, Thomas P.; Gladstone, David J.; Demidenko, Eugene; Zaki, Bassem I.; Salikhov, Ildar K.; Lesniewski, Piotr N.; Swartz, Harold M.

    2014-01-01

    Purpose The ability to estimate individual exposures to radiation following a large attack or incident has been identified as a necessity for rational and effective emergency medical response. In vivo electron paramagnetic resonance (EPR) spectroscopy of tooth enamel has been developed to meet this need. Materials and methods A novel transportable EPR spectrometer, developed to facilitate tooth dosimetry in an emergency response setting, was used to measure upper incisors in a model system, in unirradiated subjects, and in patients who had received total body doses of 2 Gy. Results A linear dose response was observed in the model system. A statistically significant increase in the intensity of the radiation-induced EPR signal was observed in irradiated versus unirradiated subjects, with an estimated standard error of dose prediction of 0.9 + 0.3 Gy. Conclusions These results demonstrate the current ability of in vivo EPR tooth dosimetry to distinguish between subjects who have not been irradiated and those who have received exposures that place them at risk for acute radiation syndrome. Procedural and technical developments to further increase the precision of dose estimation and ensure reliable operation in the emergency setting are underway. With these developments EPR tooth dosimetry is likely to be a valuable resource for triage following potential radiation exposure of a large population. PMID:21696339

  13. The use of Total Body In Vivo Neutron Activation Analysis (TBIVNAA) in balance studies in rodents

    International Nuclear Information System (INIS)

    Smith, D.A.; Lindsay, R.L.; Anderson, J.

    1976-01-01

    In the investigation of animals subject to alteration in diet or other metabolic experiments, the measurements of change in body calcium, phosphorus, sodium and nitrogen are of considerable interest. However, conventional balance studies are tedious and subject to both random and cumulative error, necessitating as they do accurate estimates of dietary intake and faecal and urinary output. The object of the present study was to determine the usefulness of total body in vivo neutron activation analysis, used at the beginning and end of the experimental period, as an alternative to conventional balance techniques. (orig.) [de

  14. High dietary protein intake is associated with an increased body weight and total death risk.

    Science.gov (United States)

    Hernández-Alonso, Pablo; Salas-Salvadó, Jordi; Ruiz-Canela, Miguel; Corella, Dolores; Estruch, Ramón; Fitó, Montserrat; Arós, Fernando; Gómez-Gracia, Enrique; Fiol, Miquel; Lapetra, José; Basora, Josep; Serra-Majem, Lluis; Muñoz, Miguel Ángel; Buil-Cosiales, Pilar; Saiz, Carmen; Bulló, Mònica

    2016-04-01

    High dietary protein diets are widely used to manage overweight and obesity. However, there is a lack of consensus about their long-term efficacy and safety. Therefore, the aim of this study was to assess the effect of long-term high-protein consumption on body weight changes and death outcomes in subjects at high cardiovascular risk. A secondary analysis of the PREDIMED trial was conducted. Dietary protein was assessed using a food-frequency questionnaire during the follow-up. Cox proportional hazard models were used to estimate the multivariate-adjusted hazard ratio (HR) and 95% confidence intervals (95%CI) for protein intake in relation to the risk of body weight and waist circumference changes, cardiovascular disease, cardiovascular death, cancer death and total death. Higher total protein intake, expressed as percentage of energy, was significantly associated with a greater risk of weight gain when protein replaced carbohydrates (HR: 1.90; 95%CI: 1.05, 3.46) but not when replaced fat (HR: 1.69; 95%CI: 0.94, 3.03). However, no association was found between protein intake and waist circumference. Contrary, higher total protein intake was associated with a greater risk of all-cause death in both carbohydrate and fat substitution models (HR: 1.59; 95%CI: 1.08, 2.35; and HR: 1.66; 95%CI: 1.13, 2.43, respectively). A higher consumption of animal protein was associated with an increased risk of fatal and non-fatal outcomes when protein substituted carbohydrates or fat. Higher dietary protein intake is associated with long-term increased risk of body weight gain and overall death in a Mediterranean population at high cardiovascular risk. Copyright © 2015 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  15. Quantitative estimation of 123I-MIBG scintigraphy in neuroblastoma. Usefulness of the total body retention rate

    International Nuclear Information System (INIS)

    Okuyama, Chio; Ushijima, Yo; Sugihara, Hiroki; Nishimura, Tunehiko

    2000-01-01

    A new method of easily and simply quantifying 123 I-MIBG accumulation as a criterion for curative effect of chemotherapy in infants with neuroblastoma was developed. This method uses the data from two images: an early image (at 5-7.5 hr) and a delayed image (at 25-32 hr). Twenty infants with untreated neuroblastoma which showed clear accumulation of 123 I-MIBG at the primary site were examined. The differences between the accumulation counts on the early image and the delayed image showed that washout of 123 I-MIBG in the neuroblastomas was delayed in tumor regions. This finding indicated that the total body 123 I-MIBG retention rate reflects the total volume of the neuroblastoma. The 123 I-MIBG retention rate was significantly higher in patients with advanced stage neuroblastoma with systemic metastases, and there was a good correlation between the retention rate and tumor markers (VMA and HVA values in urine). The response to chemotherapy paralleled the change in markers. These results suggested that the total body 123 I-MIBG retention rate is useful as a criterion for curative effect in advanced neuroblastoma. (K.H.)

  16. Radioprotective effect of Tamarindus indica pod extract in Swiss albino mice exposed to whole body electron beam radiation

    International Nuclear Information System (INIS)

    Nandini, S.; Suchetha Kumari, N.; Ganesh Sanjeev; D'sa, Prima

    2013-01-01

    The objective of the study was to investigate the radioprotective effect of Tamarindus indica pod extract against radiation induced damage.The effect of 100 mg of hydroalcoholic extract of Tamarindus indica pod was studied in Swiss albino mice exposed to 6 Gy whole body electron beam radiation. Treatment of mice with extract for 15 days before irradiation reduced the symptoms of radiation sickness when compared with the untreated irradiated group. The irradiated animals showed an elevation in lipid peroxidation and reduction in glutathione, total antioxidants and antioxidant enzymes such as glutathione peroxidase and catalase activities. Radiation induced mice has shown micronucleus in the bone marrow cells. Treatment of mice with Tamarindus indica pod extract before irradiation caused a significant reduction in lipid peroxidation followed by significant elevation in reduced glutathione, total antioxidants, glutathione peroxidase and catalase activity. It also showed a reduction in the micronucleus formation in bone marrow cells. Results indicate that the radioprotective activity of Tamarindus indica pod extract may be due to free radical scavenging attributed as a result of increased antioxidant level in mice. (author)

  17. Security Analysis of the Electronic Management System for a Total Site Utility System

    DEFF Research Database (Denmark)

    Manso Cortes, Oscar

    2016-01-01

    This paper presents the Security Analysis of the Electronic Management System (EMS) of a Total Site Utility System as proposed under the scope of the Efenis project. The Efenis project has been funded by the European Commission via the seventh framework programme (EC FP7) with the aim to improve ...

  18. Total yield of channeling radiation from relativistic electrons in thin Si and W crystals

    International Nuclear Information System (INIS)

    Abdrashitov, S.V.; Bogdanov, O.V.; Dabagov, S.B.; Pivovarov, Yu.L.; Tukhfatullin, T.A.

    2013-01-01

    Orientation dependences of channeling radiation total yield from relativistic 155–855 MeV electrons at both 〈1 0 0〉 axial and (1 0 0) planar channeling in thin silicon and tungsten crystals are studied by means of computer simulations. The model as well as computer code developed allows getting the quantitative results for orientation dependence of channeling radiation that can be used for crystal alignment in channeling experiments and/or for diagnostics of initial angular divergence of electron beam

  19. The role of total body irradiation in preparation for bone marrow transplantation in acute leukaemia. A review

    International Nuclear Information System (INIS)

    Zwaan, F.E.

    1979-01-01

    From extrapolation obtained from animal studies and radiation accidents, it is assumed that for man the LD 50 (30) will be between 300-500 rads total body irradiation (TBI) and the LD 100 at least 600 rads TBI. A dose of 1000 rads TBI is generally used in man for conditioning for bone marrow transplantation. In acute leukemia, total body irradiation is usually associated with cytoreductive chemotherapy. In Seattle 110 patients underwent bone marrow transplantation for acute leukemia in relapse. 15 patients became long term survivors. The main cause of failure were GVH, interstitial pneumonitis and leukemic relapse. New attempts are being made to improve the results: (1) better cytoreductive therapy preceding transplantation, (2) bone marrow transplantation during remission of the disease, (3) prevention of interstitial pneumonitis by modifications of the TBI technique

  20. Total proteins and protein fractions levels in pregnant rats subjected to whole-body gamma irradiation

    International Nuclear Information System (INIS)

    Mansour, M.A.; Roushdy, H.M.; Mazhar, F.M.; Abu-Gabal, H.A.

    1986-01-01

    A total number of 180 mature rats (120 females and 60 males) weighing from 120-140 g were used to study the effect of two doses (2 and 4 Gy) whole-body gamma irradiation on the level of total protein and protein fractions in serum of pregnant rats during the period of organogenesis. It was found that the levels of total protein, albumin and gamma globulins significantly decreased according to the doses of exposure. The levels of alpha and beta globulins significantly increased more in the serum of rats exposed to 2 Gy than in rats exposed to 4 Gy. The level of A/G ratio significantly decreased more in the serum of rats exposed to 2Gy than in those exposed to 4 Gy

  1. Recent Total Ionizing Dose and Displacement Damage Compendium of Candidate Electronics for NASA Space Systems

    Science.gov (United States)

    Cochran, Donna J.; Boutte, Alvin J.; Campola, Michael J.; Carts, Martin A.; Casey, Megan C.; Chen, Dakai; LaBel, Kenneth A.; Ladbury, Raymond L.; Lauenstein, Jean-Marie; Marshall, Cheryl J.; hide

    2011-01-01

    Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices.

  2. Immediate total-body CT scanning versus conventional imaging and selective CT scanning in patients with severe trauma (REACT-2): a randomised controlled trial

    NARCIS (Netherlands)

    Sierink, Joanne C.; Treskes, Kaij; Edwards, Michael J. R.; Beuker, Benn J. A.; den Hartog, Dennis; Hohmann, Joachim; Dijkgraaf, Marcel G. W.; Luitse, Jan S. K.; Beenen, Ludo F. M.; Hollmann, Markus W.; Goslings, J. Carel; Saltzherr, T. P.; Schep, N. W. L.; Streekstra, G. J.; van Lieshout, E. M. M.; Patka, P.; Klimek, M.; van Vugt, R.; Tromp, T. J. N.; Brink, M.; Harbers, J. S.; El Moumni, M.; Wendt, K. W.; Bingisser, R.; Ummenhofer, W.; Bless, N.

    2016-01-01

    Published work suggests a survival benefit for patients with trauma who undergo total-body CT scanning during the initial trauma assessment; however, level 1 evidence is absent. We aimed to assess the effect of total-body CT scanning compared with the standard work-up on in-hospital mortality in

  3. Busulfan and total body irradiation as antihematopoietic stem cell agents in the preparation of patients with congenital bone marrow disorders for allogenic bone marrow transplantation

    International Nuclear Information System (INIS)

    Parkman, R.; Rappeport, J.M.; Hellman, S.; Lipton, J.; Smith, B.; Geha, R.; Nathan, D.G.

    1984-01-01

    The capacity of busulfan and total body irradiation to ablate hematopoietic stem cells as preparation for the allogeneic bone marrow transplantation of patients with congenital bone marrow disorders was studied. Fourteen patients received 18 transplants; busulfan was used in the preparatory regimen of eight transplants and total body irradiation in the regimens of six transplants. Sustained hematopoietic ablation was achieved in six of eight patients prepared with busulfan and in all six patients prepared with total body irradiation. Three patients prepared with total body irradiation died with idiopathic interstitial pneumonitis, whereas no patients receiving busulfan developed interstitial pneumonitis. The optimal antihematopoietic stem cell agent to be used for the preparation of patients with congenital bone marrow disorder for bone marrow transplantation is not certain

  4. Electron dose-rate conversion factors for external exposure of the skin from uniformly deposited activity on the body surface

    International Nuclear Information System (INIS)

    Kocher, D.C.; Eckerman, K.F.

    1987-01-01

    Dose-rate conversion factors have been calculated for external exposure of the skin from electrons emitted by sources that are deposited uniformly on the body surface. The dose-rate factors are obtained from electron scaled point kernels developed by Berger. The dose-rate factors are calculated at depths of 4, 8, and 40 mg cm-2 below the body surface as recommended by Whitton, and at a depth of 7 mg cm-2 as recommended in ICRP Publication 26 (ICRP77). The dependence of the dose-rate factors at selected depths on the energy of the emitted electrons is displayed. The dose-rate factors for selected radionuclides of potential importance in radiological assessments are tabulated

  5. Empirical Estimation of Total Nitrogen and Total Phosphorus Concentration of Urban Water Bodies in China Using High Resolution IKONOS Multispectral Imagery

    Directory of Open Access Journals (Sweden)

    Jiaming Liu

    2015-11-01

    Full Text Available Measuring total nitrogen (TN and total phosphorus (TP is important in managing heavy polluted urban waters in China. This study uses high spatial resolution IKONOS imagery with four multispectral bands, which roughly correspond to Landsat/TM bands 1–4, to determine TN and TP in small urban rivers and lakes in China. By using Lake Cihu and the lower reaches of Wen-Rui Tang (WRT River as examples, this paper develops both multiple linear regressions (MLR and artificial neural network (ANN models to estimate TN and TP concentrations from high spatial resolution remote sensing imagery and in situ water samples collected concurrently with overpassing satellite. The measured and estimated values of both MLR and ANN models are in good agreement (R2 > 0.85 and RMSE < 2.50. The empirical equations selected by MLR are more straightforward, whereas the estimated accuracy using ANN model is better (R2 > 0.86 and RMSE < 0.89. Results validate the potential of using high resolution IKONOS multispectral imagery to study the chemical states of small-sized urban water bodies. The spatial distribution maps of TN and TP concentrations generated by the ANN model can inform the decision makers of variations in water quality in Lake Cihu and lower reaches of WRT River. The approaches and equations developed in this study could be applied to other urban water bodies for water quality monitoring.

  6. Total skin high-dose-rate electron therapy dosimetry using TG-51

    International Nuclear Information System (INIS)

    Gossman, Michael S.; Sharma, Subhash C.

    2004-01-01

    An approach to dosimetry for total skin electron therapy (TSET) is discussed using the currently accepted TG-51 high-energy calibration protocol. The methodology incorporates water phantom data for absolute calibration and plastic phantom data for efficient reference dosimetry. The scheme is simplified to include the high-dose-rate mode conversion and provides support for its use, as it becomes more available on newer linear accelerators. Using a 6-field, modified Stanford technique, one may follow the process for accurate determination of absorbed dose

  7. Secondary radiation dose during high-energy total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Janiszewska, M.; Raczkowski, M. [Lower Silesian Oncology Center, Medical Physics Department, Wroclaw (Poland); Polaczek-Grelik, K. [University of Silesia, Medical Physics Department, Katowice (Poland); Szafron, B.; Konefal, A.; Zipper, W. [University of Silesia, Department of Nuclear Physics and Its Applications, Katowice (Poland)

    2014-05-15

    The goal of this work was to assess the additional dose from secondary neutrons and γ-rays generated during total body irradiation (TBI) using a medical linac X-ray beam. Nuclear reactions that occur in the accelerator construction during emission of high-energy beams in teleradiotherapy are the source of secondary radiation. Induced activity is dependent on the half-lives of the generated radionuclides, whereas neutron flux accompanies the treatment process only. The TBI procedure using a 18 MV beam (Clinac 2100) was considered. Lateral and anterior-posterior/posterior-anterior fractions were investigated during delivery of 2 Gy of therapeutic dose. Neutron and photon flux densities were measured using neutron activation analysis (NAA) and semiconductor spectrometry. The secondary dose was estimated applying the fluence-to-dose conversion coefficients. The main contribution to the secondary dose is associated with fast neutrons. The main sources of γ-radiation are the following: {sup 56}Mn in the stainless steel and {sup 187}W of the collimation system as well as positron emitters, activated via (n,γ) and (γ,n) processes, respectively. In addition to 12 Gy of therapeutic dose, the patient could receive 57.43 mSv in the studied conditions, including 4.63 μSv from activated radionuclides. Neutron dose is mainly influenced by the time of beam emission. However, it is moderated by long source-surface distances (SSD) and application of plexiglass plates covering the patient body during treatment. Secondary radiation gives the whole body a dose, which should be taken into consideration especially when one fraction of irradiation does not cover the whole body at once. (orig.) [German] Die zusaetzliche Dosis durch sekundaere Neutronen- und γ-Strahlung waehrend der Ganzkoerperbestrahlung mit Roentgenstrahlung aus medizinischen Linearbeschleunigern wurde abgeschaetzt. Bei der Emission hochenergetischer Strahlen zur Teletherapie finden hauptsaechlich im Beschleuniger

  8. In pediatric leukemia, dose evaluation according to the type of compensators in total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Yeon [Dongnam Inst. of Radiological and Medical science, Busan (Korea, Republic of); Kim, Chang Soo; Kim, Jung Hoon [Dept. of Radiological Science, College of Health Science, Catholic University of Busan, Busan (Korea, Republic of)

    2015-04-15

    Total body irradiation (TBI) and chemotherapy are the pre-treatment method of a stem cell transplantations of the childhood leukemia. in this study, we evaluate the Quantitative human body dose prior to the treatment. The MCNPX simulation program evaluated by changing the material of the tissue compensators with imitation material of pediatric exposure in a virtual space. As a result, first, the average skin dose with the material of the tissue compensators of Plexiglass tissue compensators is 74.60 mGy/min, Al is 73.96 mGy/min, Cu is 72.26 mGy/min and Pb 67.90 mGy/min respectively. Second, regardless of the tissue compensators material that organ dose were thyroid, gentile, digestive system, brain, lungs, kidneys higher in order. Finally, the ideal distance between body compensator and the patient were 50 cm aparting each other. In conclusion, tissue compensators Al, Cu, Pb are able to replace of the currently used in Plexiglass materials.

  9. Total cross sections for electron scattering by CO2 molecules in the energy range 400 endash 5000 eV

    International Nuclear Information System (INIS)

    Garcia, G.; Manero, F.

    1996-01-01

    Total cross sections for electron scattering by CO 2 molecules in the energy range 400 endash 5000 eV have been measured with experimental errors of ∼3%. The present results have been compared with available experimental and theoretical data. The dependence of the total cross sections on electron energy shows an asymptotic behavior with increasing energies, in agreement with the Born-Bethe approximation. In addition, an analytical formula is provided to extrapolate total cross sections to higher energies. copyright 1996 The American Physical Society

  10. Calculation of total cross sections for electron and positron scattering on sodium and potassium

    International Nuclear Information System (INIS)

    McCarthy, I.E.; Ratnavelu, K.; Zhou, Y.

    1993-02-01

    Total cross sections for electron and positron scattering on sodium and potassium are calculated at various energies and compared with experiment. The method use is the coupled-channels-optical method with the equivalent-local polarisation potential, which takes all channels into account. For electrons the calculations are checked by comparison with coupled-channels-optical calculations using a detailed polarisation potential that makes only one approximation, that of weak coupling in the ionisation space. The polarisation potential for positrons includes effects of ionisation and positronium formation. 13 refs., 2 tabs

  11. Evaluation of a semi-automated computer algorithm for measuring total fat and visceral fat content in lambs undergoing in vivo whole body computed tomography.

    Science.gov (United States)

    Rosenblatt, Alana J; Scrivani, Peter V; Boisclair, Yves R; Reeves, Anthony P; Ramos-Nieves, Jose M; Xie, Yiting; Erb, Hollis N

    2017-10-01

    Computed tomography (CT) is a suitable tool for measuring body fat, since it is non-destructive and can be used to differentiate metabolically active visceral fat from total body fat. Whole body analysis of body fat is likely to be more accurate than single CT slice estimates of body fat. The aim of this study was to assess the agreement between semi-automated computer analysis of whole body volumetric CT data and conventional proximate (chemical) analysis of body fat in lambs. Data were collected prospectively from 12 lambs that underwent duplicate whole body CT, followed by slaughter and carcass analysis by dissection and chemical analysis. Agreement between methods for quantification of total and visceral fat was assessed by Bland-Altman plot analysis. The repeatability of CT was assessed for these measures using the mean difference of duplicated measures. When compared to chemical analysis, CT systematically underestimated total and visceral fat contents by more than 10% of the mean fat weight. Therefore, carcass analysis and semi-automated CT computer measurements were not interchangeable for quantifying body fat content without the use of a correction factor. CT acquisition was repeatable, with a mean difference of repeated measures being close to zero. Therefore, uncorrected whole body CT might have an application for assessment of relative changes in fat content, especially in growing lambs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. The electronic structure of molecules by a many-body approach. Pt. 1

    International Nuclear Information System (INIS)

    Niessen, W. von; Cederbaum, L.S.; Kraemer, W.P.

    1976-01-01

    The ionization potentials of benzene are studied by an ab initio many-body approach which includes the effects of electron correlation and reorganization beyond the one-particle approximation. The calculations confirm the assignment of the photoelectron spectrum experimentally proposed by Jonsson and Lindholm: 1esub(1g)(π), 2esub(2g), 1asub(2u)(π), 2esub(1u), 1bsub(2u), 1bsub(1u), 2asub(1g), 1esub(2g) in order of increasing binding energy. To definitely establish the ordering of the ionization potentials in the second band, which has been very controversial, the corresponding vibrational structure has been calculated. A number of one-electron properties are calculated in the one-particle approximation and compared to experimental work and other theoretical calculations. (orig.) [de

  13. Earthing: Health Implications of Reconnecting the Human Body to the Earth's Surface Electrons

    International Nuclear Information System (INIS)

    Chevalier, G.; Chevalier, G.; Sinatra, S.T.; Oschman, J.L.; Sokal, K.; Sokal, P.

    2012-01-01

    Environmental medicine generally addresses environmental factors with a negative impact on human health. However, emerging scientific research has revealed a surprisingly positive and overlooked environmental factor on health: direct physical contact with the vast supply of electrons on the surface of the Earth. Modern lifestyle separates humans from such contact. The research suggests that this disconnect may be a major contributor to physiological dysfunction and un wellness. Reconnection with the Earth's electrons has been found to promote intriguing physiological changes and subjective reports of well-being. Earthing (or grounding) refers to the discovery of benefits including better sleep and reduced pain from walking barefoot outside or sitting, working, or sleeping indoors connected to conductive systems that transfer the Earth's electrons from the ground into the body. This paper reviews the earthing research and the potential of earthing as a simple and easily accessed global modality of significant clinical importance

  14. Total body irradiation in the bone marrow transplantation in leukemia:an experience

    International Nuclear Information System (INIS)

    Zapatero, A.; Martin de Vidales, C.; Pinar, B.; Marin, A.; Cerezo, L.; Dominguez, P.; Perez, A.

    1996-01-01

    The purpose of this report was to evaluate long-term survival and morbidity of fractioned total body irradiation (TBI) prior to allogeneicbone marrow transplantation (BMT) for leukemia. From June 1985 to May 1992, 94 patients with acute leukemia and chronic myelogenous leukemia (CML), were treated with high dose cyclophosphamide(CY) and fractionated TBI to a total dose of 12 Gy in six fractions prior to allogeneic BMT. The Kaplan-Meier 5-year overall survival and disease-free survival were 53% +-6 and 48%+- respectively for patients with standard risk disease (first remission of acute leukemia and first chronic phase of CML), and 24%+-7 and 21%+-6 for patients with more advanced disease (p=3D0.01). The incidence of interstitial pneumonitis (IP), venoocclusive disease of the liver (VOD) and grade=3D>II acute graft-versus-host disease (GVHD) were respectively 15%, 29% and 51%. Fractionated TBI combined with high dose CY before allogeneic BMT for leukemia is an effective treatment in prolonging relapse-free survival witha low incidence of lung toxicity. (Author) 13 refs

  15. Association between electronic equipment in the bedroom and sedentary lifestyle, physical activity, and body mass index of children

    Directory of Open Access Journals (Sweden)

    Gerson Luis de Moraes Ferrari

    2015-11-01

    Full Text Available Objective: To describe the association between electronic devices in the bedroom with sedentary time and physical activity, both assessed by accelerometry, in addition to body mass index in children from São Caetano do Sul. Methods: The sample consisted of 441 children. The presence of electronic equipment (television, personal computer, and videogames in the bedroom was assessed by a questionnaire. For seven consecutive days, children used an accelerometer to objectively monitor the sedentary time and moderate-to-vigorous physical activity. Body mass index was categorized as suggested by the World Health Organization. Results: Overall, 73.9%, 54.2% and 42.8% of children had TV, computer, and videogames in the bedroom, respectively, and spent an average of 500.7 and 59.1 min/day of sedentary time and moderate-to-vigorous physical activity. Of the children, 45.3% were overweight/obese. Girls with a computer in the bedroom (45 min/day performed less moderate-to-vigorous physical activity than those without it (51.4 min/day. Similar results were observed for body mass index in boys. Moderate-to-vigorous physical activity was higher and body mass index was lower in children that had no electronic equipment in the bedroom. Presence of a computer (β = −4.798 and the combination TV + computer (β = −3.233 were negatively associated with moderate-to-vigorous physical activity. Videogames and the combinations with two or three electronic devices were positively associated with body mass index. Sedentary time was not associated with electronic equipment. Conclusion: Electronic equipment in the children's bedroom can negatively affect moderate-to-vigorous physical activity and body mass index regardless of gender, school, and annual family income, which can contribute to physical inactivity and childhood obesity. Resumo: Objetivo: Descrever a associação entre equipamentos eletrônicos no quarto com tempo sedentário e atividade f

  16. Revisiting Biomarkers of Total-Body and Partial-Body Exposure in a Baboon Model of Irradiation.

    Directory of Open Access Journals (Sweden)

    Marco Valente

    Full Text Available In case of a mass casualty radiation event, there is a need to distinguish total-body irradiation (TBI and partial-body irradiation (PBI to concentrate overwhelmed medical resources to the individuals that would develop an acute radiation syndrome (ARS and need hematologic support (i.e., mostly TBI victims. To improve the identification and medical care of TBI versus PBI individuals, reliable biomarkers of exposure could be very useful. To investigate this issue, pairs of baboons (n = 18 were exposed to different situations of TBI and PBI corresponding to an equivalent of either 5 Gy 60Co gamma irradiation (5 Gy TBI; 7.5 Gy left hemibody/2.5 right hemibody TBI; 5.55 Gy 90% PBI; 6.25 Gy 80% PBI; 10 Gy 50% PBI, 15 Gy 30% PBI or 2.5 Gy (2.5 Gy TBI; 5 Gy 50% PBI. More than fifty parameters were evaluated before and after irradiation at several time points up to 200 days. A partial least square discriminant analysis showed a good distinction of TBI from PBI situations that were equivalent to 5 Gy. Furthermore, all the animals were pooled in two groups, TBI (n = 6 and PBI (n = 12, for comparison using a logistic regression and a non parametric statistical test. Nine plasmatic biochemical markers and most of hematological parameters turned out to discriminate between TBI and PBI animals during the prodromal phase and the manifest illness phase. The most significant biomarkers were aspartate aminotransferase, creatine kinase, lactico dehydrogenase, urea, Flt3-ligand, iron, C-reactive protein, absolute neutrophil count and neutrophil-to-lymphocyte ratio for the early period, and Flt3-ligand, iron, platelet count, hemoglobin, monocyte count, absolute neutrophil count and neutrophil-to-lymphocyte ratio for the ARS phase. These results suggest that heterogeneity could be distinguished within a range of 2.5 to 5 Gy TBI.

  17. Total homocysteine is positively correlated with body mass index, waist-to-hip ratio, and fat mass among overweight reproductive women: A cross-sectional study.

    Science.gov (United States)

    Al-Bayyari, Nahla; Hamadneh, Jehan; Hailat, Rae'd; Hamadneh, Shereen

    2017-12-01

    Conflicting associations between total homocysteine (tHcy), body mass index (BMI) lean body mass, and fat mass in the general population have been reported. We investigated the hypothesis that elevated tHcy levels are associated with increased BMI, waist-to-hip ratio (WHR), and body fat mass percent. In Jordan, obesity and overweight are prevalent among reproductive women and hyperhomocysteinemia, along with obesity and overweight, are independent risk factors for cardiovascular diseases. The participants used in this cross-sectional study were 325 overweight Jordanian women aged between 18 and 49 years old. The main outcome measures were tHcy, BMI, WHR, fat mass, fat-free mass, and total body water. Serum tHcy was analyzed using a liquid chromatography tandem mass spectrophotometry (LC-MS/MS) complete kit. The body compositions were measured using a bioelectrical impedance analyzer. Study participants were stratified according to their tHcy level into two groups, ≤10 μmol/L and >10 μmol/L, and the difference between mean values of body compositions was evaluated. The tHcy was significantly and negatively correlated with age, fat-free mass, and total body water, and significantly and positively correlated with BMI, hip circumference, WHR, fat mass, and dry lean weight. The chi-square and the independent sample t-tests showed statistically significant (P ≤ .05) differences between tHcy and BMI, WHR, fat and fat-free mass, and total body water percentages. In conclusion, BMI, WHR and body fat mass were found to be associated with elevated tHcy levels among overweight reproductive women, and they might be used as independent predictors of the tHcy level. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Fast method for in-flight estimation of total dose from protons and electrons using RADE Minstrument on JUICE

    Science.gov (United States)

    Hajdas, Wojtek; Mrigakshi, Alankrita; Xiao, Hualin

    2017-04-01

    The primary concern of the ESA JUICE mission to Jupiter is the harsh particle radiation environment. Ionizing particles introduce radiation damage by total dose effects, displacement damages or single events effects. Therefore, both the total ionizing dose and the displacement damage equivalent fluence must be assessed to alert spacecraft and its payload as well as to quantify radiation levels for the entire mission lifetime. We present a concept and implementations steps for simplified method used to compute in flight a dose rate and total dose caused by protons. We also provide refinement of the method previously developed for electrons. The dose rates values are given for predefined active volumes located behind layers of materials with known thickness. Both methods are based on the electron and proton flux measurements provided by the Electron and Proton Detectors inside the Radiation Hard Electron Monitor (RADEM) located on-board of JUICE. The trade-off between method accuracy and programming limitations for in-flight computations are discussed. More comprehensive and precise dose rate computations based on detailed analysis of all stack detectors will be made during off-line data processing. It will utilize full spectral unfolding from all RADEM detector subsystems.

  19. The ACCUSCAN-II vertical scanning germanium whole body counter

    International Nuclear Information System (INIS)

    Bronson, F.L.

    1987-01-01

    The ACCUSCAN-II is manufactured by Canberra Industries, and represents a new generation of WBC systems. One or two Germanium detectors are used for precise nuclide identification. The detectors scan the total body and can accurately quantify radioactive material anywhere in the body. The shield is a full 4'' thick steel or 2'' lead and weighs about 9000 lbs. The subject can be counted standing for full body scans, or seated for longer counting times of limited portions of the body. Optional electronics also generate a count rate vs. body position profile, as an aid to interpretation of the dose implications of the count. Typical LLD's are 5 - 10 nCi for a 5 minute total body count and 0.5 - 0.7 nCi for a 5 minute long screening count. The system is available in several flavors. The manual version is an inexpensive system intended for universities, hospitals and small industrial facilities. The automatic system includes a MicroVAX-II computer and runs ABACOS0-II Body Burden Software, and is ideal for facilities with large numbers of people to count and where automated analysis of the data is desirable

  20. Total energy calculations from self-energy models

    International Nuclear Information System (INIS)

    Sanchez-Friera, P.

    2001-06-01

    Density-functional theory is a powerful method to calculate total energies of large systems of interacting electrons. The usefulness of this method, however, is limited by the fact that an approximation is required for the exchange-correlation energy. Currently used approximations (LDA and GGA) are not sufficiently accurate in many physical problems, as for instance the study of chemical reactions. It has been shown that exchange-correlation effects can be accurately described via the self-energy operator in the context of many-body perturbation theory. This is, however, a computationally very demanding approach. In this thesis a new scheme for calculating total energies is proposed, which combines elements from many-body perturbation theory and density-functional theory. The exchange-correlation energy functional is built from a simplified model of the self-energy, that nevertheless retains the main features of the exact operator. The model is built in such way that the computational effort is not significantly increased with respect to that required in a typical density-functional theory calculation. (author)

  1. Thioacetamide-induced changes in the body weight, kidney weight and the total nucleic acids content of kidney of mouse

    International Nuclear Information System (INIS)

    Shakoori, Abdul Rauf; Ashraf, Fauzia.

    1976-01-01

    Effects of thioacetamide (TAA) on the body weight, kidney weight and the total nucleic acids content of kidney of mouse were studied. TAA 1% and 2% solutions were injected intraperitoneally, twice with an interval of 24 hours in two different batches of male mice. In this way one batch received a total dose of 100 mg TAA/Kg body wt. while the other got a total dose of 200 mg TAA/Kg. Both the body as well as kidney weights decrease after TAA treatment. A total dose of 200 mg/Kg is a stronger inhibitor of growth as compared with that of 100 mg/Kg. The nucleic acids content show an increase after the drug treatment. The ribonucleic acid content of kidney increased from an average value of 4.30+0.14 mg/g kidney to 4.60+-0.22 mg/g kidney after 1% TAA treatment. The increase in 2% TAA treated mice is slightly more prominent. The deoxyribonucleic acid (DNA) content of kidney are likewise affected. After an initial increase in 1% TAA-treated animals, the DNA content gradually fall down to normal control values. Administration of 2% TAA solution causes an average increase of 21% i.e. from 1.93+-0.19 mg/g kidney wt to 2.26+-0.23 mg/g kidney wt. The size of cell, nucleus and nucleolus also increased after drug treatment, which mainly occurred during the first 24 hours of the post-treatment period

  2. De Haas-Van Alphen measurements of one-electron and many-body effects in transition metals and intermetallic compounds

    International Nuclear Information System (INIS)

    Crabtree, G.W.; Johanson, W.R.; Campbell, S.A.; Dye, D.H.; Karim, D.P.; Ketterson, J.B.

    1980-01-01

    Examples are given which demonstrate the power and versatility of the dHvA effect in studying electronic behavior in metals. In transition metals the parametrization schemes give a very complete and consistent picture of the k-dependent and surface averaged electronic properties. Because the one-electron behavior is fairly well known, the many body contribution to the Fermi velocity can be isolated and its detailed anisotropy can be displayed. This kind of information is directly relevant to the calculation of electron-phonon interaction effects and cannot be derived by any other means

  3. Increased body mass index is a predisposition for treatment by total hip replacement

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Sonne-Holm, Stig

    2005-01-01

    We investigated the radiological and epidemiological data of 4,151 subjects followed up from 1976 to 2003 to determine individual risk factors for hip osteoarthritis (OA), hip pain and/or treatment by total hip replacement (THR). Pelvic radiographs recorded in 1992 were assessed for evidence of hip......-joint degeneration and dysplasia. Sequential body mass index (BMI) measurements from 1976 to 1992, age, exposure to daily lifting and hip dysplasia were entered into logistic regression analyses. The prevalence of hip dysplasia ranged from 5.4% to 12.8% depending on the radiographical index used. Radiological hip OA...

  4. Absolute total and one and two electron transfer cross sections for Ar8+ on Ar as a function of energy

    International Nuclear Information System (INIS)

    Vancura, J.; Kostroun, V.O.

    1992-01-01

    The absolute total and one and two electron transfer cross sections for Ar 8+ on Ar were measured as a function of projectile laboratory energy from 0.090 to 0.550 keV/amu. The effective one electron transfer cross section dominates above 0.32 keV/amu, while below this energy, the effective two electron transfer starts to become appreciable. The total cross section varies by a factor over the energy range explored. The overall error in the cross section measurement is estimated to be ± 15%

  5. Total body irradiation for myasthenia gravis with thymoma: case report

    International Nuclear Information System (INIS)

    Kang, Ki Mun; Choi, Ihl Bohng; Kim, In Ah

    1999-01-01

    Myasthenia Gravis (MG) is relatively rare occuring as one of important autoimmune disease to affect neuromuscular junction. This study was clinically to evaluate total body irradiation (TBI) against two patients including 33-year and 39-year females for chronic MG with thymoma who hospitalized in the St. Mary's Hospital, Catholic University since 1994 as well as who showed no response by thymectomy, immunotherapy and hormonal therapy. TBI designed by the dose of 150-180 cGy consisting of 10 cGy per fraction, three times a week, for 5-6 weeks using linear accelerator of 6 MV. During the treatment of TBI, they did complain acute side effect such as vomiting and also appear improved physical condition from 4-6 weeks after TBI. Through the follow-up period of 18 or 42 months after TBI, they did not have any symptomatic recurrence. Consequently, the results suggest that TBI can be used as an alternative tool for the patients concurrently for MG with thymoma who had been refractory to various conventional therapies like thymectomy, immunotherapy and hormonal therapy

  6. Total body irradiation for myasthenia gravis with thymoma: case report

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ki Mun; Choi, Ihl Bohng; Kim, In Ah [College of Medicine, Catholic Univ., Seoul (Korea, Republic of)

    1999-06-01

    Myasthenia Gravis (MG) is relatively rare occuring as one of important autoimmune disease to affect neuromuscular junction. This study was clinically to evaluate total body irradiation (TBI) against two patients including 33-year and 39-year females for chronic MG with thymoma who hospitalized in the St. Mary's Hospital, Catholic University since 1994 as well as who showed no response by thymectomy, immunotherapy and hormonal therapy. TBI designed by the dose of 150-180 cGy consisting of 10 cGy per fraction, three times a week, for 5-6 weeks using linear accelerator of 6 MV. During the treatment of TBI, they did complain acute side effect such as vomiting and also appear improved physical condition from 4-6 weeks after TBI. Through the follow-up period of 18 or 42 months after TBI, they did not have any symptomatic recurrence. Consequently, the results suggest that TBI can be used as an alternative tool for the patients concurrently for MG with thymoma who had been refractory to various conventional therapies like thymectomy, immunotherapy and hormonal therapy.

  7. The Electronic Thermal Conductivity of Graphene.

    Science.gov (United States)

    Kim, Tae Yun; Park, Cheol-Hwan; Marzari, Nicola

    2016-04-13

    Graphene, as a semimetal with the largest known thermal conductivity, is an ideal system to study the interplay between electronic and lattice contributions to thermal transport. While the total electrical and thermal conductivity have been extensively investigated, a detailed first-principles study of its electronic thermal conductivity is still missing. Here, we first characterize the electron-phonon intrinsic contribution to the electronic thermal resistivity of graphene as a function of doping using electronic and phonon dispersions and electron-phonon couplings calculated from first-principles at the level of density-functional theory and many-body perturbation theory (GW). Then, we include extrinsic electron-impurity scattering using low-temperature experimental estimates. Under these conditions, we find that the in-plane electronic thermal conductivity κe of doped graphene is ∼300 W/mK at room temperature, independently of doping. This result is much larger than expected and comparable to the total thermal conductivity of typical metals, contributing ∼10% to the total thermal conductivity of bulk graphene. Notably, in samples whose physical or domain sizes are of the order of few micrometers or smaller, the relative contribution coming from the electronic thermal conductivity is more important than in the bulk limit, because lattice thermal conductivity is much more sensitive to sample or grain size at these scales. Last, when electron-impurity scattering effects are included we find that the electronic thermal conductivity is reduced by 30 to 70%. We also find that the Wiedemann-Franz law is broadly satisfied at low and high temperatures but with the largest deviations of 20-50% around room temperature.

  8. Benefits of online in vivo dosimetry for single-fraction total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Eaton, David J., E-mail: davideaton@nhs.net [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom); Warry, Alison J. [Department of Radiotherapy Physics, University College London Hospital, London (United Kingdom); Trimble, Rachel E.; Vilarino-Varela, Maria J.; Collis, Christopher H. [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom)

    2014-01-01

    Use of a patient test dose before single-fraction total body irradiation (TBI) allows review of in vivo dosimetry and modification of the main treatment setup. However, use of computed tomography (CT) planning and online in vivo dosimetry may reduce the need for this additional step. Patients were treated using a supine CT-planned extended source-to-surface distance (SSD) technique with lead compensators and bolus. In vivo dosimetry was performed using thermoluminescent dosimeters (TLDs) and diodes at 10 representative anatomical locations, for both a 0.1-Gy test dose and the treatment dose. In total, 28 patients were treated between April 2007 and July 2013, with changes made in 10 cases (36%) following test dose results. Overall, 98.1% of measured in vivo treatment doses were within 10% of the prescribed dose, compared with 97.0% of test dose readings. Changes made following the test dose could have been applied during the single-fraction treatment itself, assuming that the dose was delivered in subportions and online in vivo dosimetry was available for all clinically important anatomical sites. This alleviates the need for a test dose, saving considerable time and resources.

  9. Benefits of online in vivo dosimetry for single-fraction total body irradiation

    International Nuclear Information System (INIS)

    Eaton, David J.; Warry, Alison J.; Trimble, Rachel E.; Vilarino-Varela, Maria J.; Collis, Christopher H.

    2014-01-01

    Use of a patient test dose before single-fraction total body irradiation (TBI) allows review of in vivo dosimetry and modification of the main treatment setup. However, use of computed tomography (CT) planning and online in vivo dosimetry may reduce the need for this additional step. Patients were treated using a supine CT-planned extended source-to-surface distance (SSD) technique with lead compensators and bolus. In vivo dosimetry was performed using thermoluminescent dosimeters (TLDs) and diodes at 10 representative anatomical locations, for both a 0.1-Gy test dose and the treatment dose. In total, 28 patients were treated between April 2007 and July 2013, with changes made in 10 cases (36%) following test dose results. Overall, 98.1% of measured in vivo treatment doses were within 10% of the prescribed dose, compared with 97.0% of test dose readings. Changes made following the test dose could have been applied during the single-fraction treatment itself, assuming that the dose was delivered in subportions and online in vivo dosimetry was available for all clinically important anatomical sites. This alleviates the need for a test dose, saving considerable time and resources

  10. Enrichment increases hippocampal neurogenesis independent of blood monocyte-derived microglia presence following high-dose total body irradiation.

    Science.gov (United States)

    Ruitenberg, Marc J; Wells, Julia; Bartlett, Perry F; Harvey, Alan R; Vukovic, Jana

    2017-06-01

    Birth of new neurons in the hippocampus persists in the brain of adult mammals and critically underpins optimal learning and memory. The process of adult neurogenesis is significantly reduced following brain irradiation and this correlates with impaired cognitive function. In this study, we aimed to compare the long-term effects of two environmental paradigms (i.e. enriched environment and exercise) on adult neurogenesis following high-dose (10Gy) total body irradiation. When housed in standard (sedentary) conditions, irradiated mice revealed a long-lasting (up to 4 months) deficit in neurogenesis in the granule cell layer of the dentate gyrus, the region that harbors the neurogenic niche. This depressive effect of total body irradiation on adult neurogenesis was partially alleviated by exposure to enriched environment but not voluntary exercise, where mice were single-housed with unlimited access to a running wheel. Exposure to voluntary exercise, but not enriched environment, did lead to significant increases in microglia density in the granule cell layer of the hippocampus; our study shows that these changes result from local microglia proliferation rather than recruitment and infiltration of circulating Cx 3 cr1 +/gfp blood monocytes that subsequently differentiate into microglia-like cells. In summary, latent neural precursor cells remain present in the neurogenic niche of the adult hippocampus up to 8 weeks following high-dose total body irradiation. Environmental enrichment can partially restore the adult neurogenic process in this part of the brain following high-dose irradiation, and this was found to be independent of blood monocyte-derived microglia presence. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  11. Lung damage following bone marrow transplantation after hyperfractionated total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Latini, Paolo; Aristei, Cynthia; Checcaglini, Franco; Maranzano, Ernesto; Panizza, B.M.; Perrucci, Elisabetta (University and Hospital, Policlinico, Perugia (Italy). Radiation Oncology Service); Aversa, Franco; Martelli, M.F. (University and Hospital, Policlinico, Perugia (Italy). Department of Haematology); Raymondi, Carlo (University and Hospital, Policlinico, Perugia (Italy). Radiation Physics Service)

    1991-10-01

    From July 1985 to December 1989, 72 evaluable patients aged 6-51 (median age 27) suffering from hematological malignancies received allo-geneic bone marrow transplant (BMT) depleted of T-lymphocytes to reduce risks of graft-versus-host-disease (GvHD); 57 were matched and 15 mis-matched. Three different conditioning regiments were used in an effort to enhance cytoreduction without increase extramedullary toxicity. Mis-matched patients were treated with more immunosuppressive regimens. Total body irradiation (TBI) was given in 3 doses/day, 5 h apart over 4 days for a total of 12 fractions. The dose to the lungs was 14.4, 15.6 and 9 Gy according to the conditioning regimen. The incidence of inter-stitial pneumonia (IP) was 12.3 percent in matched and 46.7 in mis-matched patients. The results seem to indicate that lung toxicity is correlated with the intensity of the conditioning regimen, the stage of disease and, in mismatched patients, with the degree of human leucocyte antigen (HLA) disparity and the poor post-BMT reconstitution, rather than the radiotherapy dose delivered to the lungs. On the contrary, the hyperfractionated scheme adopted, the absence of GvHD and, perhaps, the post-TBI administration of cyclophosphamide all seem to have contributed to the low incidence of IP in the matched patients. (author). 30 refs.; 5 figs.; 1 tab.

  12. Lung damage following bone marrow transplantation after hyperfractionated total body irradiation

    International Nuclear Information System (INIS)

    Latini, Paolo; Aristei, Cynthia; Checcaglini, Franco; Maranzano, Ernesto; Panizza, B.M.; Perrucci, Elisabetta; Aversa, Franco; Martelli, M.F.; Raymondi, Carlo

    1991-01-01

    From July 1985 to December 1989, 72 evaluable patients aged 6-51 (median age 27) suffering from hematological malignancies received allo-geneic bone marrow transplant (BMT) depleted of T-lymphocytes to reduce risks of graft-versus-host-disease (GvHD); 57 were matched and 15 mis-matched. Three different conditioning regiments were used in an effort to enhance cytoreduction without increase extramedullary toxicity. Mis-matched patients were treated with more immunosuppressive regimens. Total body irradiation (TBI) was given in 3 doses/day, 5 h apart over 4 days for a total of 12 fractions. The dose to the lungs was 14.4, 15.6 and 9 Gy according to the conditioning regimen. The incidence of inter-stitial pneumonia (IP) was 12.3 percent in matched and 46.7 in mis-matched patients. The results seem to indicate that lung toxicity is correlated with the intensity of the conditioning regimen, the stage of disease and, in mismatched patients, with the degree of human leucocyte antigen (HLA) disparity and the poor post-BMT reconstitution, rather than the radiotherapy dose delivered to the lungs. On the contrary, the hyperfractionated scheme adopted, the absence of GvHD and, perhaps, the post-TBI administration of cyclophosphamide all seem to have contributed to the low incidence of IP in the matched patients. (author). 30 refs.; 5 figs.; 1 tab

  13. Correlation of radial bone mineral content with total body calcium in chronic renal failure

    International Nuclear Information System (INIS)

    Cohn, S.H.; Ellis, K.J.; Caselnova, R.C.; Asad, S.N.; Letteri, J.M.

    1975-01-01

    Loss of bone mineral of the skeleton in renal disease can be measured directly by total body neutron activation analysis (TBNAA), and also by an absorptiometric technique applied to the appendicular skeleton (radius). In the present study the results of these two techniques are compared in 25 patients with renal insufficiency, 53 patients with end-stage renal failure on dialysis, and 24 normal control subjects. It is apparent that there is good correlation between total body calcium (TBCa) and bone mineral content (BMC) in all groups studied. The correlation in the normal contrast group was 0.944 as compared to 0.919 for the renal patients and 0.892 for patients with end-stage renal failure on dialysis. In order to measure the relative deficit in TBCa in individual patients from the absolute Ca measurement, it is necessary to normalize the data for sex, age, and skeletal size. For this purpose, an empirically derived relationship was used to predict the normal skeletal Ca in each subject, based on weight, height, sex, and age. The measured TBCa divided by the predicted TBCa is referred to as the calcium ratio. This ratio is useful in expressing the relative deficit of Ca in individual renal patients. In similar manner, BMC data were normalized, with the same relationship used to obtain BMC ratios. The normalization procedures allow both the TBCa and BMC measurements to be used to quantitate the Ca deficit in individual patients with renal insufficiency

  14. Dosimetric analysis for photon and electron beams in Whole body irradiation

    International Nuclear Information System (INIS)

    Hurtado G, M.

    1998-01-01

    To initiate the Whole body irradiation as an alternative for the treatment of the hematological diseases, leukemia and assistant for the osseous marrow transplantation, it may be taken account the application of International Protocols about control and quality assurance. It is established the intercomparison by the different dosimetric methods: cylindrical ionization chambers and parallel plane, radiographic emulsion film, semiconductor diodes (Mosfet transistors) and TLD-100 thermoluminescent crystals, obtained measurements for 140 x 140 cm 2 fields and large distances 340 cm respect conventional fields in Radiotherapy. The in vitro dosimetry was realized at the Universal Anthropomorphic puppet Alderson Rando basically with the cylindrical crystals (1 mm diameter) of TLD-100 lithium fluoride. It was obtained the dose value with a 0.6 cm 3 cylindrical ionization chamber and the Farmer electrometer for Whole body irradiation (ICT) with photons for electrons and were obtained values with the Markus plane parallel camera. Knowing the dose rate value to the source-surface distance DFS= 80 cm, it was calibrated the crystals with the reference radiation beam of 60 Co for obtaining the response curve: Dose vs. Tl lecture. It was characterized the 10 % of the total population for 300 crystals for applying the statistics corresponding. The luminescence curve obtained of Gaussian form was considered satisfactory by its stability during the pre-anneal lecture and anneal process, getting the main peak lecture at 300 Centigrade according to assigned parameters at lecture equipment TLD Harshaw model 4500. The results indicate the functional dependence with the distance DFS= 340 cm for the following depth PPD, the relations TMR and TPR, the TAR is not calculated by the increment of the dispersion in air. The penumbra increment indicates an increase of the radiation field respect of luminous field. The dispersion angle q 1 respect at the field central axis was determined and was

  15. Recent Total Ionizing Dose Results and Displacement Damage Results for Candidate Spacecraft Electronics for NASA

    Science.gov (United States)

    Cochran, Donna J.; Buchner, Stephen P.; Irwin, Tim L.; LaBel, Kenneth A.; Marshall, Cheryl J.; Reed, Robert A.; Sanders, Anthony B.; Hawkins, Donald K.; Flanigan, Ryan J.; Cox, Stephen R.

    2005-01-01

    We present data on the vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage. Devices tested include optoelectronics, digital, analog, linear bipolar devices, hybrid devices, Analog-to- Digital Converters (ADCs), and Digital-to-Analog Converters (DACs), among others. T

  16. School-based study found that physical activity and aerobic fitness predicted increases in total body fat and abdominal fat at a mean age of 9.8 years.

    Science.gov (United States)

    Danielson, Anton; Thorsson, Ola; Karlsson, Magnus K; Wollmer, Per; Andersen, Lars B; Dencker, Magnus

    2018-02-22

    We assessed whether baseline measurements of physical activity, aerobic fitness, body fat and abdominal fat were predictors of changes in body fat measurements over a two-year period. The study comprised of 204 children aged 9.8 ± 0.6 years with a normal body mass distribution, who recruited from four schools in middle-class areas of Malmö, Sweden, from 2001 to 2004. Peak oxygen uptake and physical activity were measured at baseline. Body fat was measured by dual-energy X-ray absorptiometry at baseline and two years later. Physical activity, aerobic fitness and total body fat or abdominal fat were predictors of change in total body fat or abdominal fat over a period of two years. Changes in the percentage of body fat were not related to any of the baseline measurements. Our two-year follow-up of children with a mean age of 9.8 years at baseline showed that physical activity, aerobic fitness and body fat or abdominal fat predicted changes in total body fat or abdominal fat, but not the percentage of body fat. ©2018 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  17. One-Body Potential Theory of Molecules and Solids Modified Semiempirically for Electron Correlation

    International Nuclear Information System (INIS)

    March, N.H.

    2010-08-01

    The study of Cordero, March and Alonso (CMA) for four spherical atoms, Be,Ne,Mg and Ar, semiempirically fine-tunes the Hartree-Fock (HF) ground-state electron density by inserting the experimentally determined ionization potentials. The present Letter, first of all, relates this approach to the very recent work of Bartlett 'towards an exact correlated orbital theory for electrons'. Both methods relax the requirement of standard DFT that a one-body potential shall generate the exact ground-state density, though both work with high quality approximations. Unlike DFT, the CMA theory uses a modified HF non-local potential. It is finally stressed that this potential generates also an idempotent Dirac density matrix. The CMA approach is thereby demonstrated to relate, albeit approximately, to the DFT exchange-correlation potential. (author)

  18. TNF, IL-1 and IL-6 in circulating blood after total-body and localized irradiation in rats

    NARCIS (Netherlands)

    Haveman, J.; Geerdink, A. G.; Rodermond, H. M.

    1998-01-01

    The levels of TNF, IL-1 and IL-6 in circulating blood of female WAG/Rij rats were assessed both after total-body irradiation (TBI) and localized irradiation of the right hind leg. The results show that enhanced levels of IL-1 in the circulation reflect a stress situation presumably resulting from

  19. Compendium of Single Event Effects, Total Ionizing Dose, and Displacement Damage for Candidate Spacecraft Electronics for NASA

    Science.gov (United States)

    LaBel, Kenneth A.; OBryan, Martha V.; Chen, Dakai; Campola, Michael J.; Casey, Megan C.; Pellish, Jonathan A.; Lauenstein, Jean-Marie; Wilcox, Edward P.; Topper, Alyson D.; Ladbury, Raymond L.; hide

    2014-01-01

    We present results and analysis investigating the effects of radiation on a variety of candidate spacecraft electronics to proton and heavy ion induced single event effects (SEE), proton-induced displacement damage (DD), and total ionizing dose (TID). Introduction: This paper is a summary of test results.NASA spacecraft are subjected to a harsh space environment that includes exposure to various types of ionizing radiation. The performance of electronic devices in a space radiation environment is often limited by its susceptibility to single event effects (SEE), total ionizing dose (TID), and displacement damage (DD). Ground-based testing is used to evaluate candidate spacecraft electronics to determine risk to spaceflight applications. Interpreting the results of radiation testing of complex devices is quite difficult. Given the rapidly changing nature of technology, radiation test data are most often application-specific and adequate understanding of the test conditions is critical. Studies discussed herein were undertaken to establish the application-specific sensitivities of candidate spacecraft and emerging electronic devices to single-event upset (SEU), single-event latchup (SEL), single-event gate rupture (SEGR), single-event burnout (SEB), single-event transient (SET), TID, enhanced low dose rate sensitivity (ELDRS), and DD effects.

  20. Absolute total electronically elastic differential e--H2 scattering cross-section measurements from 1 to 19 eV

    International Nuclear Information System (INIS)

    Furst, J.; Mahgerefteh, M.; Golden, D.E.

    1984-01-01

    Absolute e - -H 2 total electronically elastic differential scattering cross sections have been determined from relative scattered-electron angular distribution measurements in the energy range from 1 to 19 eV by comparison to absolute e - -He elastic differential scattering cross sections measured in the same apparatus. Integrated total cross sections have been determined as well. Absolute differences as large as 50% between the present results and some previous results have been found, although the agreement as to shape is quite good in many cases. The present results are generally in excellent agreement with recent full rovibrational laboratory-frame close-coupling calculations

  1. Impact-parameter dependence of the total probability for electromagnetic electron-positron pair production in relativistic heavy-ion collisions

    International Nuclear Information System (INIS)

    Hencken, K.; Trautmann, D.; Baur, G.

    1995-01-01

    We calculate the impact-parameter-dependent total probability P total (b) for the electromagnetic production of electron-positron pairs in relativistic heavy-ion collisions in lowest order. We study expecially impact parameters smaller than the Compton wavelength of the electron, where the equivalent-photon approximation cannot be used. Calculations with and without a form factor for the heavy ions are done; the influence is found to be small. The lowest-order results are found to violate unitarity and are used for the calculation of multiple-pair production probabilities with the help of the approximate Poisson distribution already found in earlier publications

  2. Simultaneous measurement of milk intake and total energy expenditure in mixed-fed infants: Methodological approach and prediction of total body water

    International Nuclear Information System (INIS)

    Wells, J.C.K.; Davies, P.S.W.; Coward, W.A.

    2000-01-01

    Evaluation of the energy metabolism that underlies the new WHO breast-fed growth reference requires simultaneous measurements of milk volume intake (MVI) and total energy expenditure (TEE) by stable isotope methodologies. In young infants, such data is collected without difficulty using the dose-to-the-infant method. In older infants, where breast-milk is supplemented with non-milk foods, MVI must be measured by dosing the mother instead of the infant. This procedure would interfere with a simple measurement of infant TEE using the standard dose-to-the-infant method. Theoretically, this difficulty can be resolved by dosing the mother with deuterium and the infant with 18-oxygen, and using curve-peeling methods to calculate the infant deuterium kinetics. We propose to ascertain whether such an approach is viable in practice, such that MVI, TEE and body composition could all be measured simultaneously in mixed-fed infants. Where MVI in older infants is measured on its own, there is a need to predict infant body water in order to estimate the deuterium dilution space. Using a database of 234 infants aged 1.5 to 12 months, we provide new predictive equations by which such values may be obtained. (author)

  3. The effect of geomagnetic storm on GPS derived total electron content (TEC) at Varanasi, India

    International Nuclear Information System (INIS)

    Kumar, Sanjay; Singh, A K

    2010-01-01

    In this paper we studied the effect of geomagnetic storm on Global Positioning System (GPS) derived total electron content (TEC) at low latitude Varanasi (Geomagnetic lat 14 0 , 55' N, geomagnetic long 154 0 E) during the period of May 2007 to April 2008. During this period 2 storms were found, which were occurred on 20 November 2007 and 9 March 2008. In this study vertical total electron content (VTEC) of single Pseudorandom Noise (PRN) and average of VTEC of same PRN before 10 days of storm, which is called background TEC, were used to see the effect of these storms on the variation of TEC. From this study this is found that during the storm of March 2008 the TEC increases in main phase of storm while in the case of November 2007 storm, TEC decreases during the main phase of storm but increases in the recovery phase (next day) of storm.

  4. Total body fat, pro-inflammatory cytokines and insulin resistance in Indian subjects

    Energy Technology Data Exchange (ETDEWEB)

    Yajnik, C S [Diabetes Unit, KEM Hospital Research Centre, Pune (India); Yudkin, J S [Whittington Hospital, University College of London, London (United Kingdom); Shetty, P S [London School of Hygiene and Tropical Medicine, London (United Kingdom); Kurpad, A [St. John' s Medical College, Bangalore (India)

    1999-07-01

    There is a growing epidemic of insulin resistance syndrome (IRS) in Indians. We postulate that increased susceptibility of the urban Indians to insulin resistance is a result of a tendency to increased fat deposition from the time of intrauterine life (thrifty phenotype), exaggerated in the urban environment by a positive energy balance. The pro-inflammatory cytokines secreted by the inflammatory cells as well by the adipose tissue could aggravate insulin resistance and endothelial damage and therefore, increase the susceptibility to type 2 diabetes and coronary heart disease (CHD) independent of the previously proposed glucose fatty acid cycle mechanism. In a preliminary study, we propose to make detailed measurements of the proposed mechanisms in a selected population from 3 geographical locations in and near the city of Pune, India and also validate simple 'epidemiologic' measurements of body composition with 'reference' measurements. One hundred men (30 to 50y) each from the three geographical locations (rural, urban slum-dwellers and urban middle class in Pune) will be studied for: (i) Body composition: Anthropometric and bioimpedance measurement of total body fat (to be calibrated against deuterated water in 30 subjects from each location), and muscle mass by anthropometry and urinary creatinine excretion; (ii) Body fat distribution by subscapular- triceps ratio, waist-hip ratio; (iii) Metabolic: Glucose tolerance and insulin resistance variables (insulin, lipids, NEFA) and leptin; (iv) Endothelial markers: e-Selectin and von Willebrand Factor (vWF); (v) Inflammatory markers and pro-inflammatory cytokines: C-reactive protein (CRP), Interleukin-6 (IL-6) and tumour necrosis factor (TNF- {alpha}); (vi) Energy Balance: Assessment of nutritional intake (calories, carbohydrates, proteins and fats, n3 and n6 fatty acids) and physical activity by a questionnaire. Insulin resistance variables, endothelial markers, cytokines and obesity parameters will be compared in

  5. Total body fat, pro-inflammatory cytokines and insulin resistance in Indian subjects

    International Nuclear Information System (INIS)

    Yajnik, C.S.; Yudkin, J.S.; Shetty, P.S.; Kurpad, A.

    1999-01-01

    There is a growing epidemic of insulin resistance syndrome (IRS) in Indians. We postulate that increased susceptibility of the urban Indians to insulin resistance is a result of a tendency to increased fat deposition from the time of intrauterine life (thrifty phenotype), exaggerated in the urban environment by a positive energy balance. The pro-inflammatory cytokines secreted by the inflammatory cells as well by the adipose tissue could aggravate insulin resistance and endothelial damage and therefore, increase the susceptibility to type 2 diabetes and coronary heart disease (CHD) independent of the previously proposed glucose fatty acid cycle mechanism. In a preliminary study, we propose to make detailed measurements of the proposed mechanisms in a selected population from 3 geographical locations in and near the city of Pune, India and also validate simple 'epidemiologic' measurements of body composition with 'reference' measurements. One hundred men (30 to 50y) each from the three geographical locations (rural, urban slum-dwellers and urban middle class in Pune) will be studied for: (i) Body composition: Anthropometric and bioimpedance measurement of total body fat (to be calibrated against deuterated water in 30 subjects from each location), and muscle mass by anthropometry and urinary creatinine excretion; (ii) Body fat distribution by subscapular- triceps ratio, waist-hip ratio; (iii) Metabolic: Glucose tolerance and insulin resistance variables (insulin, lipids, NEFA) and leptin; (iv) Endothelial markers: e-Selectin and von Willebrand Factor (vWF); (v) Inflammatory markers and pro-inflammatory cytokines: C-reactive protein (CRP), Interleukin-6 (IL-6) and tumour necrosis factor (TNF- α); (vi) Energy Balance: Assessment of nutritional intake (calories, carbohydrates, proteins and fats, n3 and n6 fatty acids) and physical activity by a questionnaire. Insulin resistance variables, endothelial markers, cytokines and obesity parameters will be compared in the 3

  6. Partial and total electronic stopping cross sections of atoms and solids for protons

    International Nuclear Information System (INIS)

    Kaneko, Toshiaki.

    1990-12-01

    Based on a wave packet theory (Phys. Rev. A40, 2188(1989); Phys. Stat. Sol. (B)156,49(1989)), partial and total electronic cross sections of target elements in atomic and solid phases with atomic number Z ranging from 2 (He) to 92 (U) are tabulated shell by shell for protons with velocity v from 0.2V 0 to 2OV 0 (V 0 =2.18 x 10 8 cm/s). (author)

  7. Effects of zilpaterol hydrochloride on methane production, total body oxygen consumption, and blood metabolites in finishing beef steers

    Science.gov (United States)

    An indirect calorimetry experiment was conducted to determine the effects of feeding zilpaterol hydrochloride (ZH) for 20 d on total body oxygen consumption, respiratory quotient, methane production, and blood metabolites in finishing beef steers. Sixteen Angus steers (initial BW = 555 ± 12.7 kg) w...

  8. Comparative seric TGF(β1, β2) levels and platelets count response in total body irradiated baboons

    International Nuclear Information System (INIS)

    Mestries, J.C.; Veyret, J.; Agay, D.; Van Uye, A.; Caterini, R.; Herodin, F.; Mathieu, J.; Chancerelle, Y.

    1994-01-01

    Total body irradiation associated or not with r-hIL-6 treatment a relation between TGF-β1 and TGF-β2 blood levels and platelets count. During radio-induced thrombocytopenia, by decreasing its ability to inhibit proliferation of stem cells and megakaryocytopoiesis, the TGF-β falling induced a favorable condition for hematopoietic recovery. (author)

  9. Why do total-body decay curves of iodine-labeled proteins begin with a delay

    International Nuclear Information System (INIS)

    Regoeczi, E.

    1987-01-01

    The initial delay that occurs in total-body radiation curves reaching their single-exponential slopes was analyzed from 106 experiments involving several mammalian species (guinea pig, mouse, rabbit, and rat) and plasma proteins (alpha 1-acid glycoprotein, antithrombin III, fibrinogen, immunoglobulin G, and transferrin) in 14 different combinations. The time interval (Td) between injection and the intercept of the slope with the full-dose value was adopted as a measure of curve nonideality. The overall mean Td was 6.6 h, but individual values showed a significant correlation to protein half-lives, whereby proteins of unequal metabolic properties exhibited different mean Td values. Targeting protein to the liver abolished delay. Choice of the isotope ( 125 I or 131 I) and size of the labeled protein had no influence on the magnitude of delay. Whole-body radiation curves of animals that received [ 125 I]iodotyrosines, Na 131 I, or 131 I-polyvinylpyrrolidone exhibited no initial delays. These results do not support the earlier notion that delay is caused by a redistribution of the labeled protein in the body to radiometrically more favorable sites. However, they are compatible with the assumption that delayed passage of a protein dose through the extracellular matrix and/or retarded transfer of proteolytic products from extravascular catabolic sites to plasma may be responsible for the phenomenon

  10. Probing the electronic structure of liquid water with many-body perturbation theory

    Science.gov (United States)

    Pham, Tuan Anh; Zhang, Cui; Schwegler, Eric; Galli, Giulia

    2014-03-01

    We present a first-principles investigation of the electronic structure of liquid water based on many-body perturbation theory (MBPT), within the G0W0 approximation. The liquid quasiparticle band gap and the position of its valence band maximum and conduction band minimum with respect to vacuum were computed and it is shown that the use of MBPT is crucial to obtain results that are in good agreement with experiment. We found that the level of theory chosen to generate molecular dynamics trajectories may substantially affect the electronic structure of the liquid, in particular, the relative position of its band edges and redox potentials. Our results represent an essential step in establishing a predictive framework for computing the relative position of water redox potentials and the band edges of semiconductors and insulators. Work supported by DOE/BES (Grant No. DE-SC0008938). Work at LLNL was performed under Contract DE-AC52-07NA27344.

  11. The influence of x-ray energy on lung dose uniformity in total-body irradiation

    International Nuclear Information System (INIS)

    Ekstrand, Kenneth; Greven, Kathryn; Wu Qingrong

    1997-01-01

    Purpose: In this study we examine the influence of x-ray energy on the uniformity of the dose within the lung in total-body irradiation treatments in which partial transmission blocks are used to control the lung dose. Methods and Materials: A solid water phantom with a cork insert to simulate a lung was irradiated by x-rays with energies of either 6, 10, or 18 MV. The source to phantom distance was 3.9 meters. The cork insert was either 10 cm wide or 6 cm wide. Partial transmission blocks with transmission factors of 50% were placed anterior to the cork insert. The blocks were either 8 or 4 cm in width. Kodak XV-2 film was placed in the midline of the phantom to record the dose. Midplane dose profiles were measured with a densitometer. Results: For the 10 cm wide cork insert the uniformity of the dose over 80% of the block width varied from 6.6% for the 6 MV x-rays to 12.2% for the 18 MV x-rays. For the 6 cm wide cork insert the uniformity was comparable for all three x-ray energies, but for 18 MV the central dose increased by 9.4% compared to the 10 cm wide insert. Conclusion: Many factors must be considered in optimizing the dose for total-body irradiation. This study suggests that for AP/PA techniques lung dose uniformity is superior with 6 MV irradiation. The blanket recommendation that the highest x-ray energy be used in TBI is not valid for all situations

  12. Positioning variations of the lungs shields during total body irradiation

    International Nuclear Information System (INIS)

    Costa, A.; Marcie, S.; Boulabeiz, A.; Lagrange, J.L.

    1995-01-01

    During total body irradiation, the patient is entirely exposed to radiation and the dose to lungs have to be limited. Personalized shields are make and set between the source and the patient, in front of lungs. The patient and the shields set up are checked before the treatment session with radiographs. Verification films are performed during the treatment sessions with anterior and posterior beams. During the treatment session, the patient may move and his relative positioning can change. Also, for each daily session treatment, his positioning could be different. One way to determine position discrepancies of the shields lungs is to analyse verification films. A study has been achieved comparing positions of lungs and shields edges in digitised simulator and digitised verification images. Discrepancies on distance and angle between similar anatomical landmarks in both images are determined by applying a least squares minimisation approach. In this study, which concerns 29 patients, distance discrepancies are founded from 1,5 to 12,6 mm for the anterior beams and from 1,8 to 15,3 mm for the posterior beams. Angle discrepancies are founded from 0 to 2 degrees

  13. Dose rate and dose fractionation studies in total body irradiation of dogs

    International Nuclear Information System (INIS)

    Kolb, H.J.; Netzel, B.; Schaffer, E.; Kolb, H.

    1979-01-01

    Total body irradiation (TBI) with 800-900 rads and allogeneic bone marrow transplantation according to the regimen designated by the Seattle group has induced remissions in patients with otherwise refractory acute leukemias. Relapse of leukemia after bone marrow transplantation remains the major problem, when the Seattle set up of two opposing 60 Co-sources and a low dose rate is used in TBI. Studies in dogs with TBI at various dose rates confirmed observations in mice that gastrointestinal toxicity is unlike toxicity against hemopoietic stem cells and possibly also leukemic stem cells depending on the dose rate. However, following very high single doses (2400 R) and marrow infusion acute gastrointestinal toxicity was not prevented by the lowest dose rate studied (0.5 R/min). Fractionated TBI with fractions of 600 R in addition to 1200 R (1000 rads) permitted the application of total doses up to 300 R followed by marrow infusion without irreversible toxicity. 26 dogs given 2400-3000 R have been observed for presently up to 2 years with regard to delayed radiation toxicity. This toxicity was mild in dogs given single doses at a low dose rate or fractionated TBI. Fractionated TBI is presently evaluated with allogeneic transplants in the dog before being applied to leukemic patients

  14. Quantitative image reconstruction for total-body PET imaging using the 2-meter long EXPLORER scanner

    Science.gov (United States)

    Zhang, Xuezhu; Zhou, Jian; Cherry, Simon R.; Badawi, Ramsey D.; Qi, Jinyi

    2017-03-01

    The EXPLORER project aims to build a 2 meter long total-body PET scanner, which will provide extremely high sensitivity for imaging the entire human body. It will possess a range of capabilities currently unavailable to state-of-the-art clinical PET scanners with a limited axial field-of-view. The huge number of lines-of-response (LORs) of the EXPLORER poses a challenge to the data handling and image reconstruction. The objective of this study is to develop a quantitative image reconstruction method for the EXPLORER and compare its performance with current whole-body scanners. Fully 3D image reconstruction was performed using time-of-flight list-mode data with parallel computation. To recover the resolution loss caused by the parallax error between crystal pairs at a large axial ring difference or transaxial radial offset, we applied an image domain resolution model estimated from point source data. To evaluate the image quality, we conducted computer simulations using the SimSET Monte-Carlo toolkit and XCAT 2.0 anthropomorphic phantom to mimic a 20 min whole-body PET scan with an injection of 25 MBq 18F-FDG. We compare the performance of the EXPLORER with a current clinical scanner that has an axial FOV of 22 cm. The comparison results demonstrated superior image quality from the EXPLORER with a 6.9-fold reduction in noise standard deviation comparing with multi-bed imaging using the clinical scanner.

  15. Effect of fractionated versus unfractionated total body irradiation on the growth of the BN acute myelocytic leukemia

    International Nuclear Information System (INIS)

    Hagenbeek, A.; Martens, A.C.M.

    1981-01-01

    The efficacy of various total body irradiation (TBI) regimens prior to bone marrow transplantation was evaluated in a rat model for acute myelocytic leukemia (Dq = 85.1 cGy gamma ; N = 3.7). Using high dose rate gamma-irradiation (115 cGy/min), fractionated TBI with large total daily doses (400 to 600 cGy), either given as acute doses or as split doses at 8 hr intervals, was most effective. Split doses (2 fractions per day) offered no additional advantage. At the most, a 4 log leukemic cell kill was induced. No lethal toxicity was observed. Nine-hundred cGy flash TBI had a similar anti-tumor effect, but with this regimen almost half of the rats died from radiation-induced toxicity (lungs and gastro-intestinal tract). The results are explained in terms of differences between normal and leukemic cells as regards (a) repair of sublethal damage; and (b) repopulation. Low dose rate continuous gamma-irradiation (0.26 cGy/min) with total doses ranging from 900 to 2000 cGy was also quite effective. Maximally a 4 log cell kill was obtained. With 2000 cGy, 50% of the rats died from the gastro-intestinal tract-syndrome. In addition to the major role played by chemotherapy, TBI is mainly of importance in sterilizing the various sanctuaries in the body which contain leukemic cells anatomically resistant to most cytostatic agents

  16. Deciphering the relationship among phosphate dynamics, electron-dense body and lipid accumulation in the green alga Parachlorella kessleri

    Czech Academy of Sciences Publication Activity Database

    Ota, S.; Yoshihara, M.; Yamazaki, T.; Takeshita, T.; Hirata, A.; Konomi, M.; Oshima, K.; Hattori, M.; Bišová, Kateřina; Zachleder, Vilém; Kawano, S.

    2016-01-01

    Roč. 6, MAY 16 (2016), s. 25731 ISSN 2045-2322 Institutional support: RVO:61388971 Keywords : electron-dense body * lipid accumulation * Parachlorella kessleri Subject RIV: EE - Microbiology, Virology Impact factor: 4.259, year: 2016

  17. Total body irradiation in intensive treatment necessitating bone marrow graft, of malignant hematological diseases

    International Nuclear Information System (INIS)

    Regnier, R.; Van Houtte, P.; Piron, A.; Debusscher, L.; Strijckmans, P.

    1990-01-01

    From 1980 to 1988, 65 consecutive patients were treated with a program of intensive chemotherapy and total body irradiation (TBI) for malignant hematological diseases at the Institut Jules-Bordet. Results were analyzed according to different prognostic factors as well as to the radiation technique; 3 different schedules were used: 3 fractions of 2.66 Gy given in one day at 3-h intervals, 6 daily fractions of 2 Gy in 6 days and 7 fractions of 2.25 Gy in 8 days. The second radiation schedule appears to give the best results as relapses were higher with the 1-day program and there was an increase in later effects and early deaths with 7 fractions of 2.25 Gy. Nevertheless, the results indicate that after administration of 5 or 6 times 2 Gy TBI, there might be possible benefit in treating certain parts of the body by radiation, those in particular that could be sanctuary sites for malignant cells from chemotherapy. The authors propose a simple and easy way of uniformizing the radiation schedule to carry out a multicentric trial [fr

  18. Cobalt-60 total body irradiation dosimetry at 220 cm source-axis distance

    International Nuclear Information System (INIS)

    Glasgow, G.P.; Mill, W.B.

    1980-01-01

    Adults with acute leukemia are treated with cyclophosphamide and total body irradiation (TBI) followed by autologous marrow transplants. For TBI, patients seated in a stand angled 45 0 above the floor are treated for about 2 hours at 220 cm source-axis distance (SAD) with sequential right and left lateral 87 cm x 87 cm fields to a 900 rad mid-pelvic dose at about 8 rad/min using a 5000 Ci cobalt unit. Maximum (lateral) to minimum (mid-plane) dose ratios are: hips--1.15, shoulders--1.30, and head--1.05, which is shielded by a compensator filter. Organ doses are small intestine, liver and kidneys--1100 rad, lung--1100 to 1200 rad, and heart--1300 rad. Verification dosimetry reveals the prescribed dose is delivered to within +-5%. Details of the dosimetry of this treatment are presented

  19. Measuring GNSS ionospheric total electron content at Concordia, and application to L-band radiometers

    Directory of Open Access Journals (Sweden)

    Vincenzo Romano

    2013-06-01

    Full Text Available In the framework of the project BIS - Bipolar Ionospheric Scintillation and Total Electron Content Monitoring, the ISACCO-DMC0 and ISACCO-DMC1 permanent monitoring stations were installed in 2008. The principal scope of the stations is to measure the ionospheric total electron content (TEC and to monitor the ionospheric scintillations, using high-sampling-frequency global positioning system (GPS ionospheric scintillation and TEC monitor (GISTM receivers. The disturbances that the ionosphere can induce on the electromagnetic signals emitted by the Global Navigation Satellite System constellations are due to the presence of electron density anomalies in the ionosphere, which are particularly frequent at high latitudes, where the upper atmosphere is highly sensitive to perturbations coming from outer space. With the development of present and future low-frequency space-borne microwave missions (e.g., Soil Moisture and Ocean Salinity [SMOS], Aquarius, and Soil Moisture Active Passive missions, there is an increasing need to estimate the effects of the ionosphere on the propagation of electromagnetic waves that affects satellite measurements. As an example, how the TEC data collected at Concordia station are useful for the calibration of the European Space Agency SMOS data within the framework of an experiment promoted by the European Space Agency (known as DOMEX will be discussed. The present report shows the ability of the GISTM station to monitor ionospheric scintillation and TEC, which indicates that only the use of continuous GPS measurements can provide accurate information on TEC variability, which is necessary for continuous calibration of satellite data.

  20. Association between electronic equipment in the bedroom and sedentary lifestyle, physical activity, and body mass index of children

    Directory of Open Access Journals (Sweden)

    Gerson Luis de Moraes Ferrari

    2015-11-01

    Conclusion: Electronic equipment in the children's bedroom can negatively affect moderate‐to‐vigorous physical activity and body mass index regardless of gender, school, and annual family income, which can contribute to physical inactivity and childhood obesity.

  1. Total and single differential cross sections for the electron impact ionization of the ground state of helium

    International Nuclear Information System (INIS)

    Singh, T.S.C.; Choudhury, K.B.; Singh, M.B.; Deb, N.C.; Mukherjee, S.C.; Mazumdar, P.S.

    1997-01-01

    Total cross sections (TCS) and single differential cross sections (SDCS) have been computed for the single ionization of the ground state of helium by electron impact in a distorted wave formalism which takes into account the effects of the initial and final channel distortions. The present TCS and SDCS results are in fair agreement with the measured values and other theoretical predictions for the incident electron energy E i > 150 eV. (orig.)

  2. Some results of ionospheric total electron content and scintillation observations at Lunping

    International Nuclear Information System (INIS)

    Huang, Y.N.

    1981-01-01

    An analysis is conducted of the characteristic variations of the ionospheric total electron content (TEC), slab thickness, and scintillation activity observed at Lunping Observatory. The employed data have been obtained by measuring the Faraday rotation angle of the 136.1124 MHz beacon signal transmitted from the Japanese ETS-II geostationary satellite. Diurnal, seasonal, and solar cycle variations of TEC are discussed, taking into account real seasonal variations of TEC and geomagnetic storm effects. Geomagnetic storm effects on the variation of the slab thickness are studied by selecting 90 SC type geomagnetic storms which occurred during the period from March 1977 to June 1980

  3. Electron-ion recombination in merged beams

    International Nuclear Information System (INIS)

    Wolf, A.; Habs, D.; Lampert, A.; Neumann, R.; Schramm, U.; Schuessler, T.; Schwalm, D.

    1993-01-01

    Detailed studies of recombination processes between electrons and highly charged ions have become possible by recent improvements of merged-beams experiments. We discuss in particular measurements with stored cooled ion beams at the Test Storage Ring (TSR) in Heidelberg. The cross section of dielectronic recombination was measured with high energy resolution for few-electron systems up to the nuclear charge of Cu at a relative energy up to 2.6 keV. At low energy (∼0.1 eV) total recombination rates of several ions were measured and compared with calculated radiative recombination rates. Laser-stimulated recombination of protons and of C 6+ ions was investigated as a function of the photon energy using visible radiation. Both the total recombination rates and the stimulated recombination spectra indicate that in spite of the short interaction time in merged beams, also collisional capture of electrons into weakly bound levels (related to three-body recombination) could be important

  4. Life-Course Genome-wide Association Study Meta-analysis of Total Body BMD and Assessment of Age-Specific Effects

    NARCIS (Netherlands)

    Medina-Gomez, Carolina; Kemp, John P.; Trajanoska, Katerina; Luan, Jian'an; Chesi, Alessandra; Ahluwalia, Tarunveer S.; Mook-Kanamori, Dennis O.; Ham, Annelies; Hartwig, Fernando P.; Evans, Daniel S.; Joro, Raimo; Nedeljkovic, Ivana; Zheng, Hou-Feng; Zhu, Kun; Atalay, Mustafa; Liu, Ching-Ti; Nethander, Maria; Broer, Linda; Porleifsson, Gudmar; Mullin, Benjamin H.; Handelman, Samuel K.; Nalls, Mike A.; Jessen, Leon E.; Heppe, Denise H. M.; Richards, J. Brent; Wang, Carol; Chawes, Bo; Schraut, Katharina E.; Amin, Najaf; Wareham, Nick; Karasik, David; van der Velde, Nathalie; Ikram, M. Arfan; Zemel, Babette S.; Zhou, Yanhua; Carlsson, Christian J.; Liu, Yongmei; McGuigan, Fiona E.; Boer, Cindy G.; Bønnelykke, Klaus; Ralston, Stuart H.; Robbins, John A.; Walsh, John P.; Zillikens, M. Carola; Langenberg, Claudia; Li-Gao, Ruifang; Williams, Frances M. K.; Harris, Tamara B.; Akesson, Kristina; Jackson, Rebecca D.; Sigurdsson, Gunnar; den Heijer, Martin; van der Eerden, Bram C. J.; van de Peppel, Jeroen; Spector, Timothy D.; Pennell, Craig; Horta, Bernardo L.; Felix, Janine F.; Zhao, Jing Hua; Wilson, Scott G.; de Mutsert, Renée; Bisgaard, Hans; Styrkársdóttir, Unnur; Jaddoe, Vincent W.; Orwoll, Eric; Lakka, Timo A.; Scott, Robert; Grant, Struan F. A.; Lorentzon, Mattias; van Duijn, Cornelia M.; Wilson, James F.; Stefansson, Kari; Psaty, Bruce M.; Kiel, Douglas P.; Ohlsson, Claes; Ntzani, Evangelia; van Wijnen, Andre J.; Forgetta, Vincenzo; Ghanbari, Mohsen; Logan, John G.; Williams, Graham R.; Bassett, J. H. Duncan; Croucher, Peter I.; Evangelou, Evangelos; Uitterlinden, Andre G.; Ackert-Bicknell, Cheryl L.; Tobias, Jonathan H.; Evans, David M.; Rivadeneira, Fernando

    2018-01-01

    Bone mineral density (BMD) assessed by DXA is used to evaluate bone health. In children, total body (TB) measurements are commonly used; in older individuals, BMD at the lumbar spine (LS) and femoral neck (FN) is used to diagnose osteoporosis. To date, genetic variants in more than 60 loci have been

  5. Life-Course Genome-wide Association Study Meta-analysis of Total Body BMD and Assessment of Age-Specific Effects

    DEFF Research Database (Denmark)

    Medina-Gomez, Carolina; Kemp, John P.; Trajanoska, Katerina

    2018-01-01

    Bone mineral density (BMD) assessed by DXA is used to evaluate bone health. In children, total body (TB) measurements are commonly used; in older individuals, BMD at the lumbar spine (LS) and femoral neck (FN) is used to diagnose osteoporosis. To date, genetic variants in more than 60 loci have b...

  6. Association between electronic equipment in the bedroom and sedentary lifestyle, physical activity, and body mass index of children

    OpenAIRE

    Ferrari, Gerson Luis de Moraes; Araújo, Timóteo Leandro; Oliveira, Luis Carlos; Matsudo, Victor; Fisberg, Mauro

    2015-01-01

    Objective: To describe the association between electronic devices in the bedroom with sedentary time and physical activity, both assessed by accelerometry, in addition to body mass index in children from São Caetano do Sul. Methods: The sample consisted of 441 children. The presence of electronic equipment (television, personal computer, and videogames) in the bedroom was assessed by a questionnaire. For seven consecutive days, children used an accelerometer to objectively monitor the sede...

  7. Evaluation of Arabic Language Learning Program for Non-Native Speakers in Saudi Electronic University According to Total Quality Standards

    Science.gov (United States)

    Alowaydhi, Wafa Hafez

    2016-01-01

    The current study aimed at standardizing the program of learning Arabic for non-native speakers in Saudi Electronic University according to certain standards of total quality. To achieve its purpose, the study adopted the descriptive analytical method. The author prepared a measurement tool for evaluating the electronic learning programs in light…

  8. Incorporation of threshold phenomena in the three-body Coulomb continuum wavefunctions

    International Nuclear Information System (INIS)

    Berakdar, J.

    1996-01-01

    In this work a three-body Coulomb wavefunction for the description of two continuum electrons moving in the field of a nucleus is constructed such that the Wannier threshold law for double escape is reproduced and the asymptotic Coulomb boundary conditions as well as the Kato cusp conditions are satisfied. It is shown that the absolute value of the total cross section, as well as the spin asymmetry, are well described by the present approach. Further, the excess-energy sharing between the two escaping electrons is calculated and analysed in light of the Wannier theory predictions. This is the first time an analytical three-body wavefunction is presented which is asymptotically exact and capable of describing threshold phenomena. 37 refs., 3 figs

  9. Total electron scattering cross section from pyridine molecules in the energy range 10-1000 eV

    Science.gov (United States)

    Dubuis, A. Traoré; Costa, F.; da Silva, F. Ferreira; Limão-Vieira, P.; Oller, J. C.; Blanco, F.; García, G.

    2018-05-01

    We report on experimental total electron scattering cross-section (TCS) from pyridine (C5H5N) for incident electron energies between 10 and 1000 eV, with experimental uncertainties within 5-10%, as measured with a double electrostatic analyser apparatus. The experimental results are compared with our theoretical calculations performed within the independent atom model complemented with a screening corrected additivity rule (IAM-SCAR) procedure which has been updated by including interference effects. A good level of agreement is found between both data sources within the experimental uncertainties. The present TCS results for electron impact energy under study contribute, together with other scattering data available in the literature, to achieve a consistent set of cross section data for modelling purposes.

  10. Inhaled /sup 147/Pm and/or total-body gamma radiation: Early mortality and morbidity in rats

    Energy Technology Data Exchange (ETDEWEB)

    Filipy, R.E.; Lauhala, K.E.; McGee, D.R.; Cannon, W.C.; Buschbom, R.L.; Decker, J.R.; Kuffel, E.G.; Park, J.F.; Ragan, H.A.; Yaniv, S.S.; Scott, B.R.

    1989-05-01

    Rats were given doses of /sup 60/Co gamma radiation and/or lung burdens of /sup 147/Pm (in fused aluminosilicate particles) within lethal ranges in an experiment to determine and compare morbidity and mortality responses for the radiation insults within 1 year after exposure. Radiation-induced morbidity was assessed by measuring changes in body weights, hematologic parameters, and pulmonary-function parameters. Acute mortality and morbidity from inhaled promethium were caused primarily by radiation pneumonitis and pulmonary fibrosis that occurred more than 53 days after exposure. Acute mortality and morbidity from total-body gamma irradiation occurred within 30 days of exposure and resulted from the bone-marrow radiation syndrome. Gamma radiation caused transient morbidity, reflected by immediately depressed blood cell levels and by reduced body weight gain in animals that survived the acute gamma radiation syndrome. Inhaled promethium caused a loss of body weight and diminished pulmonary function, but its only effect on blood cell levels was lymphocytopenia. Combined gamma irradiation and promethium lung burdens were synergistic, in that animals receiving both radiation insults had higher morbidity and mortality rates than would be predicted based on the effect of either kind of radiation alone. Promethium lung burdens enhanced the effect of gamma radiation in rats within the first 30 days of exposure, and gamma radiation enhanced the later effect of promethium lung burdens. 70 refs., 68 figs., 21 tabs.

  11. Age dependency in the absorption of radioactive Iodine (131I) in the thyroid and total body of newborn, pubertal and adult fischer 344 rats

    International Nuclear Information System (INIS)

    Nitta, Yumiko; Endo, Satoru; Fujimoto, Nariaki; Kamiya, Kenji; Ohtaki, Megu; Hayakawa, Norihiko; Takada, Jun; Hoshi, Masaharu

    1998-01-01

    In this study, activities of 131 I in the thyroid, total body and blood were measured for rats of three different ages to estimate the movement of 131 I in the body, the absorbed doses were calculated in the thyroid and total body under the exposed condition of iodine deficiency and sufficiency, and the standard curves for the determination of absorbed doses in the thyroid and total body were obtained for rats of newborn, pubertal and adult. Authors used female rats of Fisher 344 strain in this experiment and set up twelve experimental group of different ages (1, 4 and 9 weeks old), and divided each age group into one standard diet (SD) group and three iodine deficient diet (IDD) groups. Rats were intravenously injected once with 131 I in 0.9% saline with the activity of 0.38, 1.03 and 9.42 kBq per g weight. In the thyroid and total body, the absorbed dose values increased in an injected activity-dependent manner, and those of 1-week-old rats were significantly higher than those of 4- and 9-weeks old rats. The absorbed dose values in IDD-treated groups were higher than those in the SD-treated groups. The speed of 131 I accumulation into the thyroid and that of 131 I excretion from the body was slow in 1-week-old groups. The data also showed that most of injected 131 I distributed in the thyroid and blood in 4- and 9-week-old groups but not in the 1-week-old group, indicating that 131 I is pooled in certain tissues or organs except the thyroid in rats of the 1-week-old group at which the development of the thyroid has not been completed. Standard curves were obtained for the estimation of absorbed doses in the thyroid and total body on the bases of injected activity of 131 I for each age group of rats. These standard curves are to be used in the carcinogenesis experiment which compare the effectiveness of internal with external irradiation under the condition of iodine deficiency or sufficiency in the rats of different ages. (K.H.)

  12. Total body irradiation: what schedule(s). Les irradiations corporelles totales: quel(s) schema(s)

    Energy Technology Data Exchange (ETDEWEB)

    Cosset, J M [Institut Curie, 75 - Paris (France)

    1993-01-01

    In this article, the author explains why a whole-body irradiation is still an essential step before a bone marrow graft. He presents irradiation protocols for acute myeloid leukemia and chronic myeloid leukemia. 14 refs.

  13. Whole body retention of 99mTc-diphosphonate. Relation to bio-chemical indices of bone turnover and to total body calcium

    International Nuclear Information System (INIS)

    Thomsen, K.; Johansen, J.; Nilas, L.; Christiansen, C.

    1987-01-01

    Whole body retention (WBR) and urinary excretion (UE) of 99m Te-diphosphonate were determined in 161 healthy adults and the results were compared to accepted biochemical markers of bone turnover. WBR was corrected for total body bone mineral (TBBM) and UE from forearm bone mineral content (BMC). Both uncorrected and corrected retention measurements were highly significantly correlated to the biochemical markers (P<0.001), but the r values were low (0.22-0.64). All bone turnover variables demonstrated considerably higher levels of bone turnover in postmenopausal women than in premenopausal women (P<0.001), whereas the variables were unchanged with age in men. The correction of WBR for TBBM and UE for BMC increased the validity of the retention methods and the two calculations gave exactly the same results on a group basis, both demonstrating significantly higher bone turnover in women than in men in each age group (P<0.05-P<0.001). All the turnover variables were measured in a group of perimenopausal women (n=33). The data clearly demonstrated that bone turnover is menopause dependent, whereas age in itself is of minor significance. (orig.)

  14. Linac-based total body irradiation (TBI) with volumetric modulated arc therapy (VMAT)

    Science.gov (United States)

    Tas, B.; Durmus, I. F.; Okumus, A.; Uzel, O. E.

    2017-02-01

    To evaluate dose distribution of Volumetric modulated arc therapy (VMAT) planning tecnique using Versa HD® lineer accelerator to deliver Total Body Irradiation (TBI) on the coach. Eight TBI patient's Treatment Planning System (TPS) were performed with dual arc VMAT for each patient. The VMAT-TBI consisted of three isocentres and three dual overlapping arcs. The prescribed dose was 12 Gy. Mean dose to lung and kidney were restricted less than 10 Gy and max. dose to lens were restricted less than 6 Gy. The plans were verified using 2D array and ion chamber. The comparison between calculation and measurement were made by γ-index analysis and absolute dose. An average total delivery time was determined 923±34 seconds and an average MU was determined 2614±228 MUs for dual arc VMAT. Mean dose to lungs was 9.7±0.2 Gy, mean dose to kidneys was 8.8±0.3 Gy, max. dose to lens was 5.5±0.3 Gy and max. dose was 14.6±0.3 Gy, HI of PTV was 1.13±0.2, mean dose to PTV was 12.6±1.5 Gy and mean γ-index pass rate was %97.1±1.9. The results show that the tecnique for TBI using VMAT on the treatment coach is feasible.

  15. Endocrine dysfunction after total body irradiation and bone marrow transplantation

    International Nuclear Information System (INIS)

    Feyer, P.; Titlbach, O.; Hoffmann, F.A.; Kubel, M.; Helbig, W.; Leipzig Univ.

    1989-01-01

    Data regarding changes of endocrine parameters after total body irradiation (TBI) and bone marrow transplantation (BMT) are described. Endocrine glands are usually resistant to irradiation under morphological aspects. But new methods of determination and sensitive tests were developed in the last few years. Now it is possible to detect already small functional changes. Endocrine studies in the course of the disease were followed serially in 16 patients with TBI and BMT. Pretransplant conditioning consisted of single-dose irradiation combined with a high-dose, short-term chemotherapy. Reactions of the endocrine system showed a defined temporary order. Changes of ACTH and cortisol were in the beginning. The pituitary-adrenal cortex system responds in a different way. The pituitary-thyroid system develops a short-term 'low-T 3 -syndrome' reflecting the extreme stress of the organism. At the same time we obtained an increase of thyroxine. Testosterone and luteotropic hormone, the sexual steroids showed levels representing a primary gonadal insufficiency. The studies in the posttransplant period yielded a return to the normal range at most of the hormonal levels with the exception of the sexual steroids. Sterility is one of the late effects of TBI. A tendency towards hypothyroidism could be noticed in some cases being only subclinical forms. Reasons and possible therapy are discussed. (author)

  16. Influence of radioprotectors on total body weight evolution and on oxygen consumption in lethal dose irradiated animals. (Preliminary study)

    International Nuclear Information System (INIS)

    Fatome, M.; Martine, G.; Bargy, E.; Andrieu, L.

    Comparison of total body weight evolution and oxygen consumption in lethal dose irradiated animals, protected by various well known radioprotective substances, isolated or in mixture, with evolution and consumption of non protected animals irradiated at the same dose and with these of check animals [fr

  17. Medium modified two-body scattering amplitude from proton-nucleus total cross-sections

    Science.gov (United States)

    Tripathi, R. K.; Wilson, J. W.; Cucinotta, F. A.

    2001-01-01

    Recently (R.K. Tripathi, J.W. Wilson, F.A. Cucinotta, Nucl. Instr. and Meth. B 145 (1998) 277; R.K. Tripathi, F.A. Cucinotta, J.W. Wilson, NASA-TP-1998-208438), we have extracted nucleon-nucleon (N-N) cross-sections in the medium directly from experiment. The in-medium N-N cross-sections form the basic ingredients of several heavy-ion scattering approaches including the coupled-channel approach developed at the NASA Langley Research Center. Here, we investigate the ratio of real to imaginary part of the two-body scattering amplitude in the medium. These ratios are used in combination with the in-medium N-N cross-sections to calculate total proton-nucleus cross-sections. The agreement is excellent with the available experimental data. These cross-sections are needed for the radiation risk assessment of space missions. c2001 Elsevier Science B.V. All rights reserved.

  18. Pilot production of the wedge filter for the TBI (total body irradiation)

    International Nuclear Information System (INIS)

    Ikezaki, Hiromi; Ikeda, Ikuo; Maruyama, Yasushi; Nako, Yasunobu; Tonari, Ayako; Kusuda, Junko; Takayama, Makoto

    2007-01-01

    Total body irradiation (TBI) is performed by various methods, such as a long SSD method and a translational couch method. For patient safety in carrying out TBI, the patient should be placed on the supine position and prone position near the floor. TBI is performed from 2 opposite ports (AP/PA) with a linear accelerator (10 MV X-ray). We experimented with a wedge filter for TBI created by us, which makes dose distribution to a floor uniform. The wedge filter, made of iron alloy, was attached to the linear accelerator. In designing the wedge filter, thickness of the lead-made wedge filter can be calculated numerically from the ratio of linear attenuation coefficient of iron alloy and lead. In measuring the dose profile for a phantom of 20 cm thick, dose homogeneity less than 10% was proved by the wedge filter for TBI. (author)

  19. Electron-plasmon and electron-phonon satellites in the angle-resolved photoelectron spectra of n -doped anatase TiO2

    Science.gov (United States)

    Caruso, Fabio; Verdi, Carla; Poncé, Samuel; Giustino, Feliciano

    2018-04-01

    We develop a first-principles approach based on many-body perturbation theory to investigate the effects of the interaction between electrons and carrier plasmons on the electronic properties of highly doped semiconductors and oxides. Through the evaluation of the electron self-energy, we account simultaneously for electron-plasmon and electron-phonon coupling in theoretical calculations of angle-resolved photoemission spectra, electron linewidths, and relaxation times. We apply this methodology to electron-doped anatase TiO2 as an illustrative example. The simulated spectra indicate that electron-plasmon coupling in TiO2 underpins the formation of satellites at energies comparable to those of polaronic spectral features. At variance with phonons, however, the energy of plasmons and their spectral fingerprints depends strongly on the carrier concentration, revealing a complex interplay between plasmon and phonon satellites. The electron-plasmon interaction accounts for approximately 40% of the total electron-boson interaction strength, and it is key to improve the agreement with measured quasiparticle spectra.

  20. Electron-helium S-wave model benchmark calculations. II. Double ionization, single ionization with excitation, and double excitation

    Science.gov (United States)

    Bartlett, Philip L.; Stelbovics, Andris T.

    2010-02-01

    The propagating exterior complex scaling (PECS) method is extended to all four-body processes in electron impact on helium in an S-wave model. Total and energy-differential cross sections are presented with benchmark accuracy for double ionization, single ionization with excitation, and double excitation (to autoionizing states) for incident-electron energies from threshold to 500 eV. While the PECS three-body cross sections for this model given in the preceding article [Phys. Rev. A 81, 022715 (2010)] are in good agreement with other methods, there are considerable discrepancies for these four-body processes. With this model we demonstrate the suitability of the PECS method for the complete solution of the electron-helium system.

  1. Observing bodies. Camera surveillance and the significance of the body.

    NARCIS (Netherlands)

    Dubbeld, L.

    2003-01-01

    At the most mundane level, CCTV observes bodies, and as such attaches great importance to the specific features of the human body. At the same time, however, bodies tend to disappear, as they are represented electronically by the camera monitors and, in the case of image recording, by the computer

  2. Tsallis non-extensive statistical mechanics in the ionospheric detrended total electron content during quiet and storm periods

    Science.gov (United States)

    Ogunsua, B. O.; Laoye, J. A.

    2018-05-01

    In this paper, the Tsallis non-extensive q-statistics in ionospheric dynamics was investigated using the total electron content (TEC) obtained from two Global Positioning System (GPS) receiver stations. This investigation was carried out considering the geomagnetically quiet and storm periods. The micro density variation of the ionospheric total electron content was extracted from the TEC data by method of detrending. The detrended total electron content, which represent the variation in the internal dynamics of the system was further analyzed using for non-extensive statistical mechanics using the q-Gaussian methods. Our results reveals that for all the analyzed data sets the Tsallis Gaussian probability distribution (q-Gaussian) with value q > 1 were obtained. It was observed that there is no distinct difference in pattern between the values of qquiet and qstorm. However the values of q varies with geophysical conditions and possibly with local dynamics for the two stations. Also observed are the asymmetric pattern of the q-Gaussian and a highly significant level of correlation for the q-index values obtained for the storm periods compared to the quiet periods between the two GPS receiver stations where the TEC was measured. The factors responsible for this variation can be mostly attributed to the varying mechanisms resulting in the self-reorganization of the system dynamics during the storm periods. The result shows the existence of long range correlation for both quiet and storm periods for the two stations.

  3. Study on the immunological suppressive mechanisms of the cyclophosphamide-administration and total body irradiation

    International Nuclear Information System (INIS)

    Wakizaka, Yoshitaka; Uchino, Junichi; Yang, Zi-Bo.

    1994-01-01

    High dose-cyclophosphamide (CP) administration and total body irradiation (TBI) are often used for bone marrow transplantation in order to eradicate the residual tumor cells and to induce the immunological tolerance in the recipients. But CP is difficult to use as an immunosuppressant because this drug has indefinite effects on host's immune status depending on the dose, i.e. augment the humoral antibody production in small dosage and inhibit the rejective reaction in large dosage. Thus we study on the immunological mechanisms of this drug and the TBI used often with CP for bone marrow transplantation in leukemic patients. 150 mg/kg of CP was administered via tail vein, and 3 Gy (300 rads) of X-ray was irradiated. CP could suppress the host's cellular immunity within 5 days after administration but TBI could within 3 days. Reversely, CP augmented the cellular immunity since 5 days after treatment. CP damaged the IL-2 production irreversibely, but IL-3 production was inhibited by CP for only a few days and recovered rapidly. These characters were thought to be a big help for the implantation and development of the multipotent stem cells in the recipient's body after transplantation. (author)

  4. In vivo dosimetry for total body irradiation: five‐year results and technique comparison

    Science.gov (United States)

    Warry, Alison J.; Eaton, David J.; Collis, Christopher H.; Rosenberg, Ivan

    2014-01-01

    The aim of this work is to establish if the new CT‐based total body irradiation (TBI) planning techniques used at University College London Hospital (UCLH) and Royal Free Hospital (RFH) are comparable to the previous technique at the Middlesex Hospital (MXH) by analyzing predicted and measured diode results. TBI aims to deliver a homogeneous dose to the entire body, typically using extended SSD fields with beam modulation to limit doses to organs at risk. In vivo dosimetry is used to verify the accuracy of delivered doses. In 2005, when the Middlesex Hospital was decommissioned and merged with UCLH, both UCLH and the RFH introduced updated CT‐planned TBI techniques, based on the old MXH technique. More CT slices and in vivo measurement points were used by both; UCLH introduced a beam modulation technique using MLC segments, while RFH updated to a combination of lead compensators and bolus. Semiconductor diodes were used to measure entrance and exit doses in several anatomical locations along the entire body. Diode results from both centers for over five years of treatments were analyzed and compared to the previous MXH technique for accuracy and precision of delivered doses. The most stable location was the field center with standard deviations of 4.1% (MXH), 3.7% (UCLH), and 1.7% (RFH). The least stable position was the ankles. Mean variation with fraction number was within 1.5% for all three techniques. In vivo dosimetry can be used to verify complex modulated CT‐planned TBI, and demonstrate improvements and limitations in techniques. The results show that the new UCLH technique is no worse than the previous MXH one and comparable to the current RFH technique. PACS numbers: 87.55.Qr, 87.56.N‐ PMID:25207423

  5. The role of total body fat mass and trunk fat mass, combined with other endocrine factors, in menstrual recovery and psychopathology of adolescents with Anorexia Nervosa.

    Science.gov (United States)

    Karountzos, Vasileios; Lambrinoudaki, Irene; Tsitsika, Artemis; Deligeoroglou, Efthimios

    2017-10-01

    To determine the threshold of total body and trunk fat mass required for menstrual recovery and to assess the impact of body composition in psychopathology of adolescents with Anorexia Nervosa (AN). Prospective study of 60 adolescents presented with secondary amenorrhea and diagnosed with AN. Anthropometrics, body composition by dual-energy X-ray absorptiometry, hormonal studies and responses to mental health screens (EAT-26), were obtained at the beginning and at complete weight restoration, in all adolescents, independently of menstrual recovery (Group A) or not (Group B). At weight restoration, Group A total body fat mass, trunk fat mass, and trunk/extremities fat ratio were significantly higher (p psychopathology of adolescents with AN.

  6. Fiber-coupled Al_2O_3:C radioluminescence dosimetry for total body irradiations

    International Nuclear Information System (INIS)

    Buranurak, S.; Andersen, C.E.

    2016-01-01

    In vivo dosimetry can be important and relevant in radiotherapy, especially when commissioning new treatment techniques at hospitals. This study investigates the potential use of fiber-coupled radioluminescence (RL) dosimetry based on Al_2O_3:C or organic plastic scintillators for this purpose in the context of Total Body Irradiations (TBIs) where patients are treated with large fields of 6 or 18 MV photons at an extended source-to-surface distance (SSD). The study shows that Al_2O_3:C dosimetry using the saturated-RL protocol may be suitable for real-time in vivo dosimetry during TBI treatments from the perspective of the good agreement with alanine dosimetry and other critical phantom tests, including the ability to cope with the large stem signal experienced during TBI treatments at extended SSD. In contrast, the chromatic stem removal technique often used for organic plastic scintillators did not work well in large fields with the tested calibration procedure and instrumentation. An apparent dose-rate effect discussed in a previous study of the RL properties of Al_2O_3:C (Andersen et al., 2011) was found to have resulted from an overlooked dead time problem in the counting system, and this potential caveat can therefore be removed from the list of potential problems associated with fiber-coupled Al_2O_3:C dosimetry using the saturated-RL protocol. This further has implications for TBI dosimetry using the RL Al_2O_3:C system due to large dose-rate differences between calibrations at the iso-center and in vivo measurements at extended source-to-surface distances. - Highlights: • Fiber-coupled dosimetry can be used for measurements during total body irradiations. • An apparent dose-effect associated with radioluminescence from Al2O3:C was resolved. • The gated-counting stem removal procedure worked well for Al2O3:C in pulsed accelerator beams. • The chromatic stem removal procedure did not work well with the tested instrumentation and organic plastic

  7. Penelope simulation of electron beams 6 MeV from a linear accelerator for studies in different materials equivalent to human body

    International Nuclear Information System (INIS)

    Apaza V, D.; Cardena R, R.; Cayllahua Q, F.; Vega R, J.; Urquizo B, R.

    2015-10-01

    In systems of radiotherapy treatment for cancer, always looking to maximize the radiation dose on the target (tumor) and minimize to the organs at risk or healthy, so they resort to using electron beams that have properties and characteristics of higher dose deposition at fixed depths, directing and focusing the higher dose in the tumor, without harming healthy tissues to which seeks to radiate in the least possible. Simulating the interaction of electron beams with different equivalent tissues to the human body leads to a better dosimetric evaluation, improving the quality of treatment planning. The aim of this study is the comparison from the characterization of several equivalent tissues to the human body such as soft tissue, bone and lung. Based on the simulation of a calibration beam in water phantom with Penelope code and compared with the results of the calibration curves of beams in water vat by a linear accelerator Elekta Synergy of Hospital Nacional Carlos Alberto Seguin Escobedo EsSalud of Arequipa (Peru). From this to evaluate the behavior of electron beams in a homogeneous medium and then further evaluation in the human body homogeneities, for better evaluation and specific treatment planning. (Author)

  8. Low-dose (10-Gy) total skin electron beam therapy for cutaneous T-cell lymphoma

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Gniadecki, Robert; Iversen, Lars

    2015-01-01

    a total dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. RESULTS: The overall response rate was 95% with a complete cutaneous response......PURPOSE: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments...... or a very good partial response rate (response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. CONCLUSIONS...

  9. Age-dependent exposure to radioactive iodine (131I) in the thyroid and total body of newborn, pubertal and adult fischer 344 rats

    International Nuclear Information System (INIS)

    Nitta, Yumiko; Fujimoto, Nariaki; Kamiya, Kenji; Hoshi, Masaharu; Endo, Satoru

    2001-01-01

    Female rats of the Fischer 344 strain at ages of 1, 4 and 9 weeks were exposed to 131 I intraperitoneally with activities of 0.38, 1.03 and 3.42 kBq per gram of body weight under the condition of iodine deficiency. The absorbed doses in the thyroid increased linearly depending on the injected activities. Irradiation at 1 week old caused heavier exposure than those at 4 and 9 weeks old by 7.5 and 7.7 times, respectively; however, damage of the thyroid tissue was more obvious in the 4-week-old groups than in the 1-week-old groups. The absorbed doses in the total body were proportional to the square root of the injected activities. The one-week-old groups were exposed more heavily than the 4- and 9-week-old groups by 3.6 and 4.7 times, respectively, shown by the slow excretion of 131 I with the values of effective half-life of 131 I activity (T eff ). An IDD-treatment was not so effective to enhance the 131 I absorption in the total body, as in the thyroid. No matter how the iodine concentration in the blood changed, the 1-week-old groups could not react to normalize the level. We drew standard curves, which enabled us to estimate the absorbed doses in the thyroid and the total body in the case of the injected activities of 131 I for the newborn, pubertal and adult rats. (author)

  10. Fetal subcutaneous tissue measurements in pregnancy as a predictor of neonatal total body composition.

    Science.gov (United States)

    O'Connor, Clare; Doolan, Anne; O'Higgins, Amy; Segurado, Ricardo; Sheridan-Pereiraet, Margaret; Turner, Michael J; Stuart, Bernard; Kennelly, Máireád M

    2014-10-01

    The purpose of this study was to examine the relationship between prenatal measures of subcutaneous tissue as surrogate markers of fetal nutritional status and correlate them with neonatal total body composition. This prospective longitudinal study of 62 singleton pregnancies obtained serial biometry and subcutaneous tissue measurements at 28, 33 and 38 weeks gestation. These measurements were then correlated with neonatal body composition, which was analysed using the PEAPOD™ Infant Body Composition System (Cosmed USA, Concord, CA, USA). At 38 weeks gestation, fetal abdominal subcutaneous tissue (FAST) in millimetres was significantly associated with infant fat mass at delivery (+64 g per mm of FAST, p < 0.001). Thigh fat (TF) at 28 weeks gestation was associated with infant fat mass at delivery (+79 g/mm TF, p = 0.023). TF at 38 weeks gestation was associated with infant fat mass (+63/mm TF, p = 0.004). TF and FAST at 38 weeks were also predictive of both birth weight and increased abdominal circumference (AC) (p = 0.001) with FAST measurement predicting an additional 5.7 mm in AC per millimetre of FAST (p = 0.002) and TF predicting an additional 6.9 mm per mm of TF (p = 0.002). We believe that this study further validates the use of prenatal measures of subcutaneous tissue and may help to highlight fetuses at risk of newborn adiposity and metabolic syndrome. © 2014 John Wiley & Sons, Ltd.

  11. Zernike phase contrast cryo-electron tomography of sodium-driven flagellar hook-basal bodies from Vibrio alginolyticus.

    Science.gov (United States)

    Hosogi, Naoki; Shigematsu, Hideki; Terashima, Hiroyuki; Homma, Michio; Nagayama, Kuniaki

    2011-01-01

    Vibrio alginolyticus use flagella to swim. A flagellum consists of a filament, hook and basal body. The basal body is made up of a rod and several ring structures. This study investigates the structure of the T ring which is a unique component of the V. alginolyticus sodium ion-driven flagellar basal body. Using Zernike phase contrast (ZPC) cryo-electron tomography, we compared the 3D structures of purified hook-basal bodies (HBB) from a wild-type strain (KK148) and a deletion mutant lacking MotX and MotY (TH3), which are thought to form the T ring. ZPC images of HBBs had highly improved signal-to-noise ratio compared to conventional phase contrast images. We observed the outline of the HBBs from strains KK148 and TH3, and the TH3 mutant was missing its T ring. In the wild-type strain, the T ring was beneath the LP ring and seemed to form a ring shape with diameter of 32 nm. Copyright © 2010 Elsevier Inc. All rights reserved.

  12. Communication: electronic band gaps of semiconducting zig-zag carbon nanotubes from many-body perturbation theory calculations.

    Science.gov (United States)

    Umari, P; Petrenko, O; Taioli, S; De Souza, M M

    2012-05-14

    Electronic band gaps for optically allowed transitions are calculated for a series of semiconducting single-walled zig-zag carbon nanotubes of increasing diameter within the many-body perturbation theory GW method. The dependence of the evaluated gaps with respect to tube diameters is then compared with those found from previous experimental data for optical gaps combined with theoretical estimations of exciton binding energies. We find that our GW gaps confirm the behavior inferred from experiment. The relationship between the electronic gap and the diameter extrapolated from the GW values is also in excellent agreement with a direct measurement recently performed through scanning tunneling spectroscopy.

  13. Disturbances in dental development after total body irradiation in bone marrow transplant recipients

    International Nuclear Information System (INIS)

    Dahlloef, G.B.; Barr, M.; Bolme, P.; Modeer, T.; Loennqvist, B.R.; Ringden, O.; Heimdahl, A.

    1988-01-01

    The dental status of 16 children who had been treated with bone marrow transplantation (BMT) for serious bone marrow diseases was followed for up to 6 years. Several types of disturbances in dental development were observed in children who had been conditioned with total body irradiation (TBI) at 10 Gy before BMT. Thus, impaired root development that caused short V-shaped roots was found in all patients, a complete failure of root development and premature apical closure were found in five patients, enamel hypoplasia was observed in four patients, and microdontia was observed in three patients conditioned with TBI. Patients younger than 6 years of age at BMT exhibited the most severe and extensive dental aberrations. The TBI at 10 Gy appeared to be the major cause of the disturbances found

  14. Partial and total electronic stopping cross sections of atoms for a singly charged helium ion, Part 2

    International Nuclear Information System (INIS)

    Kaneko, T.; Nishikori, M.; Yamato, N.

    1991-08-01

    Partial and total electronic stopping cross sections of atoms with Z (55 ≤ Z ≤ 92) for a He + ion are tabulated as the second part of NIFS-DATA-11 (1991) on the basis of the wave-packet theory. (author)

  15. Recent development of transient electronics

    Directory of Open Access Journals (Sweden)

    Huanyu Cheng

    2016-01-01

    Full Text Available Transient electronics are an emerging class of electronics with the unique characteristic to completely dissolve within a programmed period of time. Since no harmful byproducts are released, these electronics can be used in the human body as a diagnostic tool, for instance, or they can be used as environmentally friendly alternatives to existing electronics which disintegrate when exposed to water. Thus, the most crucial aspect of transient electronics is their ability to disintegrate in a practical manner and a review of the literature on this topic is essential for understanding the current capabilities of transient electronics and areas of future research. In the past, only partial dissolution of transient electronics was possible, however, total dissolution has been achieved with a recent discovery that silicon nanomembrane undergoes hydrolysis. The use of single- and multi-layered structures has also been explored as a way to extend the lifetime of the electronics. Analytical models have been developed to study the dissolution of various functional materials as well as the devices constructed from this set of functional materials and these models prove to be useful in the design of the transient electronics.

  16. Interobserver Reliability of the Total Body Score System for Quantifying Human Decomposition.

    Science.gov (United States)

    Dabbs, Gretchen R; Connor, Melissa; Bytheway, Joan A

    2016-03-01

    Several authors have tested the accuracy of the Total Body Score (TBS) method for quantifying decomposition, but none have examined the reliability of the method as a scoring system by testing interobserver error rates. Sixteen participants used the TBS system to score 59 observation packets including photographs and written descriptions of 13 human cadavers in different stages of decomposition (postmortem interval: 2-186 days). Data analysis used a two-way random model intraclass correlation in SPSS (v. 17.0). The TBS method showed "almost perfect" agreement between observers, with average absolute correlation coefficients of 0.990 and average consistency correlation coefficients of 0.991. While the TBS method may have sources of error, scoring reliability is not one of them. Individual component scores were examined, and the influences of education and experience levels were investigated. Overall, the trunk component scores were the least concordant. Suggestions are made to improve the reliability of the TBS method. © 2016 American Academy of Forensic Sciences.

  17. Bone marrow transplantation in the patients with malignant tumor. Studies on supralethal total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Tatsuno, Ikuro; Saito, Yasuo

    1984-11-01

    Based on evidence gained from ten patients of allogeneic bone marrow transplantation (BMT) and eight patients of autologous BMT, recent knowledge on literatures of BMT and total body irradiation (TBI) is summarized. Interstitial pneumonia after BMT has a strong correlation with TBI. Low dose-rate and fractionation of TBI are seemed to reduce the lung injury, thereby reducing the incidence of nonleukemia deaths. BMT is applied to not only acute leukemia, malignant lymphoma and solid tumors but also to chronic leukemia. It is emphasized that several of the important prognostic factors are within the control of the transplantation team.

  18. Behavioural consequences of an 8 Gy total body irradiation in mice: Regulation by interleukin-4

    International Nuclear Information System (INIS)

    Van der Meeren, A.; Lebaron-Jacobs, L.

    2001-01-01

    The effects of an 8 Gy γ total body irradiation (TBI) on exploration and locomotion activities as well as temperature were studied in C57BL6/J mice. Survival, body weight, and blood cell counts were also assessed in irradiated mice treated with placebo or interleukin (IL)-4. The efficacy of IL-4 treatment on improvement in exploration activity was evaluated. The study was carried out from 3 h to 30 days following exposure. Our results showed a biphasic response to irradiation concerning the exploration activity of mice. Irradiated mice had reduced activity as early as 3 h after exposure, with recovery of activity within 24 h. The exploration activity again decreased 4 days after irradiation and the recovery occurred slowly after day 17. IL-4 ameliorated the exploration status in mice in both phases. The locomotion activity was studied using a telemetry apparatus. A similar pattern to that of the exploration data was observed, with a minimal activity observed between days 13 and 17. A radiation-induced hypothermia was also noticed over the same time period. (author)

  19. Behavioural consequences of an 8 Gy total body irradiation in mice: Regulation by interleukin-4

    Energy Technology Data Exchange (ETDEWEB)

    Van der Meeren, A.; Lebaron-Jacobs, L. [Inst. de Protection et de Surete Nucleaire, Dept. de Protection de la sante de l' Homme et de Dosimetrie, Section Autonome de Radiobiologie Appliquee a la Medecine, IPSN, Fontenay-aux-Roses (France)

    2001-02-01

    The effects of an 8 Gy {gamma} total body irradiation (TBI) on exploration and locomotion activities as well as temperature were studied in C57BL6/J mice. Survival, body weight, and blood cell counts were also assessed in irradiated mice treated with placebo or interleukin (IL)-4. The efficacy of IL-4 treatment on improvement in exploration activity was evaluated. The study was carried out from 3 h to 30 days following exposure. Our results showed a biphasic response to irradiation concerning the exploration activity of mice. Irradiated mice had reduced activity as early as 3 h after exposure, with recovery of activity within 24 h. The exploration activity again decreased 4 days after irradiation and the recovery occurred slowly after day 17. IL-4 ameliorated the exploration status in mice in both phases. The locomotion activity was studied using a telemetry apparatus. A similar pattern to that of the exploration data was observed, with a minimal activity observed between days 13 and 17. A radiation-induced hypothermia was also noticed over the same time period. (author)

  20. The evaluation of a modified technique of Total Body Irradiation in respect of treatment results and toxicity

    International Nuclear Information System (INIS)

    Skowronska-Gardas, A.; Dabrowski, R.; Pedziwiatr, K.

    2006-01-01

    Total body irradiation (TBI) is a well established part of the conditioning regimen prior to bone marrow transplantation (BMT). Numerous different techniques are used and every center elaborates own solutions. The aim of our study to present the method of TBI developed in our department, and to discuss the results of treatment with respect of early and late toxicity. Between 11.2000 and 08.2004, 23 patients were with fractionated TBI at the Department of Radiotherapy of the M. Sklodowska-Curie Memorial Cancer Center and Institute of Oncology in Warsaw (MSCMCC). Conditioning chemotherapy and BMT were performed in different hematological departments. All patients were irradiated with a total midline dose of 12 Gy in 6 fractions over 3 consecutive days. Doses to the lung did not exceed 11 Gy. The TBI method used in our department was evaluated over a few years. The following modifications have been introduced to the previously applied technique: change of photon energy 6 MV to 15 MV; increase of lung dose from 9 Gy to 11 Gy; the use of an individual bolus as a lung compensator in lateral fields; more frequent boost irradiation of the mediastinum and legs with small fields; calculations of Monitor Units based on dosimetric data. Boost irradiation of chest wall with electrons been abandoned. Median follow up was 12 months. Up till now, 17/23 patients are alive, of these 16 with no relapse. Immediate toxicity was low. Early complications were observed during the first 6 months after BMT in 11 patients. In the case of 4 patients these complications were fatal. Late complications were observed in 10 patients, including chronic GVHD and hormone disturbance. Only one patient had developed the first symptoms of cataract. In one case Lhermitte's syndrome was observed. One patient died due to liver insufficiency. The results of treatment and the complications rates in patients treated with TBI at our department are consistent with those published in literature. We conclude that

  1. Body composition of adult cystic fibrosis patients and control subjects as determined by densitometry, bioelectrical impedance, total-body electrical conductivity, skinfold measurements, and deuterium oxide dilution

    International Nuclear Information System (INIS)

    Newby, M.J.; Keim, N.L.; Brown, D.L.

    1990-01-01

    This study contrasts body compositions (by six methods) of eight cystic fibrosis (CF) subjects with those of eight control subjects matched for age, height, and sex. CF subjects weighed 84% as much as control subjects. Densitometry and two bioelectrical impedance-analysis methods suggested that reduced CF weights were due to less lean tissue (10.7, 9.5, and 10.4 kg). Total-body electrical conductivity (TOBEC) and skinfold-thickness measurements indicated that CF subjects were leaner than control subjects and had less fat (5.4 and 3.6 kg) and less lean (5.2 and 7 kg) tissue. D2O dilution showed a pattern similar to TOBEC (8.3 kg less lean, 2.7 kg less fat tissue). Densitometry estimates of fat (mass and percent) were not correlated (r less than 0.74, p greater than 0.05) with any other method for CF subjects but were correlated with all other methods for control subjects. CF subjects contained less fat and lean tissue than did control subjects. Densitometry by underwater weighing is unsuitable for assessing body composition of CF patients

  2. Density-density functionals and effective potentials in many-body electronic structure calculations

    International Nuclear Information System (INIS)

    Reboredo, Fernando A.; Kent, Paul R.

    2008-01-01

    We demonstrate the existence of different density-density functionals designed to retain selected properties of the many-body ground state in a non-interacting solution starting from the standard density functional theory ground state. We focus on diffusion quantum Monte Carlo applications that require trial wave functions with optimal Fermion nodes. The theory is extensible and can be used to understand current practices in several electronic structure methods within a generalized density functional framework. The theory justifies and stimulates the search of optimal empirical density functionals and effective potentials for accurate calculations of the properties of real materials, but also cautions on the limits of their applicability. The concepts are tested and validated with a near-analytic model.

  3. Proposal for electron beam induced remote sensing x-ray fluorescence investigation of minor bodies in the solar system

    International Nuclear Information System (INIS)

    Hrehuss, G.; Gombosi, T.I.; Naday, I.; Pogany, L.; Szegoe, K.

    1983-11-01

    The composition of the surface material of minor bodies in the solar system can be measured using a semiconductor soft x-ray spectrometer mounted on the space probe. The characteristic x-rays are excited by a 20 kV low current electron beam of a space-born electron gun. After the description of the main features of the technique, estimations on its sensitivity, supported by a model experiment, are given. The minimum fly-by distance to apply this method can be estimated as a few kilometers. (author)

  4. Uptake of carbon monoxide by C3H mice following X irradiation of lung only or total-body irradiation with 60Co

    International Nuclear Information System (INIS)

    Rappaport, D.S.; Niewoehner, D.E.; Kim, T.H.; Song, C.W.; Levitt, S.H.

    1983-01-01

    Carbon monoxide uptake (V/sub co/) and ventilation rate (VR) of C3H mice were determined at 14 weeks following either X irradiation of lungs only or total-body irradiation with 60 Co at different dose rates. Following localized X irradiation of lung at 97 /sub c/Gy/min there was a reduction in V/sub co/, which was inversely related to radiation dose, with a small reduction below control levels being detected at 7 Gy, the lowest dose tested. An increase in VR could be detected only at doses of 11 Gy, or more. Another group of animals received 11.5 Gy total-body irradiation at either 26.2 or 4.85 /sub c/Gy/min fllowed by transplantation with syngeneic bone marrow. Following total-body irradiation, V/sub co/ was significantly reduced by about 37% at the higher dose rate and 23% at the lower dose rate. In contrast, a trend toward elevated VR was detected only at the higher dose rate.The results indicate that V/sub co/ is a sensitive indicator of radiation-induced lung injury and that under the experimental conditions used V/sub co/ is a more sensitive indicator of radiation-induced lung injury in C3H mice than VR

  5. Time- and radiation-dose dependent changes in the plasma proteome after total body irradiation of non-human primates: Implications for biomarker selection.

    Directory of Open Access Journals (Sweden)

    Stephanie D Byrum

    Full Text Available Acute radiation syndrome (ARS is a complex multi-organ disease resulting from total body exposure to high doses of radiation. Individuals can be exposed to total body irradiation (TBI in a number of ways, including terrorist radiological weapons or nuclear accidents. In order to determine whether an individual has been exposed to high doses of radiation and needs countermeasure treatment, robust biomarkers are needed to estimate radiation exposure from biospecimens such as blood or urine. In order to identity such candidate biomarkers of radiation exposure, high-resolution proteomics was used to analyze plasma from non-human primates following whole body irradiation (Co-60 at 6.7 Gy and 7.4 Gy with a twelve day observation period. A total of 663 proteins were evaluated from the plasma proteome analysis. A panel of plasma proteins with characteristic time- and dose-dependent changes was identified. In addition to the plasma proteomics study reported here, we recently identified candidate biomarkers using urine from these same non-human primates. From the proteomic analysis of both plasma and urine, we identified ten overlapping proteins that significantly differentiate both time and dose variables. These shared plasma and urine proteins represent optimal candidate biomarkers of radiation exposure.

  6. Hyperfractionated total body irradiation for bone marrow transplantation. Results in seventy leukemia patients with allogeneic transplants

    International Nuclear Information System (INIS)

    Shank, B.; Chu, F.C.H.; Dinsmore, R.

    1983-01-01

    From May, 1979 to March, 1981, 76 leukemia patients were prepared for bone marrow transplantation (BMT) with a new hyperfractionated total body irradiation (TBI) regimen (1320 cGy in 11 fractions, 3x/day), followed by cyclophosphamide, 60 mg/kg, for two days. Partial lung shielding was done on each treatment, with supplemental electron beam treatments of the chest wall to compensate, and of the testes, a sanctuary site. This regimen was initiated to potentially reduce fatal interstitial pneumonitis as well as decrease leukemic relapse. Overall actuarial survival at 1 year for acute non-lymphocytic leukemia (ANLL) patients is 63%, while relapse-free survival at 1 year is 53%. On the other hand, for acute lymphocytic leukemia (ALL) patients, there is no significant difference between relapse or remission patients with regard to overall survival or relapse-free survival, when relapse is defined as > 5% blasts in the marrow at the time of cytoreduction. Overall actuarial survival at 1 year for ALL is 61% and relapse-free survival is 45% at 1 year. Fatal interstitial pneumonitis has dropped to 18% compared with 50% in our previous single-dose TBI regimen (1000 cGy), in which the same doses of cyclophosphamide were given prior to TBI. In conclusion, not only has fatal interstitial pneumonitis been reduced by hyperfractionation and partial lung blocking, but there may be a survival advantage in ALL patients in relapse, who have a survival equal to that of remission patients. This may indicate a greater cell kill with the higher dose (1320 cGy) attained with this regimen, in these patients with a higher leukemic cell burden

  7. [French experience in paediatric total body irradiation: A study from the radiotherapy committee of the Société française des cancers de l'enfant (SFCE)].

    Science.gov (United States)

    Demoor-Goldschmidt, C; Supiot, S; Claude, L; Carrie, C; Mazeron, R; Helfré, S; Alapetite, C; Jouin, A; Coche, B; Padovani, L; Muracciole, X; Bernier, V; Vigneron, C; Noël, G; Leseur, J; Le Prisé, É; Stefan, D; Habrand, J L; Kerr, C; Bondiau, P Y; Ruffier, A; Chapet, S; Mahé, M A

    2016-06-01

    A survey was conducted in 2015 in France on the care of children in radiotherapy services. We present the results for total body irradiation in children, a specific technique of radiation treatment, which needs dedicated controls for this particular population. Of the 17 centres interviewed, 16 responded, and 13 practiced total body irradiation. Patients are positioned in lateral decubitus in 11 centres and supine/prone in two centres. Doses used for total body irradiation in myeloablative bone marrow transplantation are the same in all centres (12Gy); treatments are always fractionated. Lung shielding is positioned to limit the dose at an average of 8Gy with extremes ranging from 6 to 10Gy. The shape of the shieldings varies depending on departments' protocol, with a smaller size in case of mediastinal mass. Four centres have experience of total body irradiation under general anaesthesia, despite twice-daily fractions. In total, practice is relatively homogeneous throughout France and is inspired by the knowledge obtained in adults. Copyright © 2016 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  8. Dose-escalated total body irradiation and autologous stem cell transplantation for refractory hematologic malignancy

    International Nuclear Information System (INIS)

    McAfee, Steven L.; Powell, Simon N.; Colby, Christine; Spitzer, Thomas R.

    2002-01-01

    Purpose: To evaluate the feasibility of dose escalation of total body irradiation (TBI) above the previously reported maximally tolerated dose, we have undertaken a Phase I-II trial of dose-escalated TBI with autologous peripheral blood stem cell transplantation (PBSCT) for chemotherapy-refractory lymphoma. Methods and Materials: Nine lymphoma patients with primary refractory disease (PRD) or in resistant relapse (RR) received dose-escalated TBI and PBSCT. The three dose levels of fractionated TBI (200 cGy twice daily) were 1,600 cGy, 1,800 cGy, and 2,000 cGy. Lung blocks were used to reduce the TBI transmission dose by 50%, and the chest wall dose was supplemented to the prescribed dose using electrons. Shielding of the kidneys was performed to keep the maximal renal dose at 1,600 cGy. Three patients, two with non-Hodgkin's lymphoma (NHL) in RR and one with PRD Hodgkin's disease, received 1,600 cGy + PBSCT, three patients (two NHL in RR, one PRD) received 1,800 cGy + PBSCT, and three patients with NHL (two in RR, one PRD) received 2,000 cGy + PBSCT. Results: Toxicities associated with this high-dose TBI regimen included reversible hepatic veno-occlusive disease in 1 patient, Grade 2 mucositis requiring narcotic analgesics in 8 patients, and neurologic toxicities consisting of a symmetrical sensory neuropathy (n=4) and Lhermitte's syndrome (n=1). Interstitial pneumonitis developed in 1 patient who received 1,800 cGy after receiving recombinant α-interferon (with exacerbation after rechallenge with interferon). Six (66%) patients achieved a response. Four (44%) patients achieved complete responses, three of which were of a duration greater than 1 year, and 2 (22%) patients achieved a partial response. One patient remains disease-free more than 5 years posttransplant. Corticosteroid-induced gastritis and postoperative infection resulted in the death of 1 patient in complete response, 429 days posttransplant. Conclusion: TBI in a dose range 1,600-2,000 cGy as

  9. Increased body mass index is a predisposition for treatment by total hip replacement

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Sonne-Holm, Stig

    2005-01-01

    -joint degeneration and dysplasia. Sequential body mass index (BMI) measurements from 1976 to 1992, age, exposure to daily lifting and hip dysplasia were entered into logistic regression analyses. The prevalence of hip dysplasia ranged from 5.4% to 12.8% depending on the radiographical index used. Radiological hip OA...... prevalence was 1.0--2.5% in subjects or=60 years of age. While radiological OA was significantly influenced by hip dysplasia in men and hip dysplasia and age in women, the risk of THR being performed was only influenced by BMI assessed in 1976. Hip......We investigated the radiological and epidemiological data of 4,151 subjects followed up from 1976 to 2003 to determine individual risk factors for hip osteoarthritis (OA), hip pain and/or treatment by total hip replacement (THR). Pelvic radiographs recorded in 1992 were assessed for evidence of hip...

  10. Whole-body dose meters. Measurements of total activity

    International Nuclear Information System (INIS)

    Koeppe, P.; Klinikum Steglitz, Berlin

    1990-01-01

    By means of measurements using a whole-body dose meter, the course of the incorporation of radionuclides was established between April 1986 and May 1989 for unchanged conditions of alimentation, activity-conscious alimentation, and uniquely increased incorporation. Monitoring covered persons from the most different spheres of life. The incorporation is compared with the one resulting from nuclear weapons explosions in the atmosphere. (DG) [de

  11. THE IMPACT OF MODERATE AND HIGH INTENSITY TOTAL BODY FATIGUE ON PASSING ACCURACY IN EXPERT AND NOVICE BASKETBALL PLAYERS

    Directory of Open Access Journals (Sweden)

    Mark Lyons

    2006-06-01

    Full Text Available Despite the acknowledged importance of fatigue on performance in sport, ecologically sound studies investigating fatigue and its effects on sport-specific skills are surprisingly rare. The aim of this study was to investigate the effect of moderate and high intensity total body fatigue on passing accuracy in expert and novice basketball players. Ten novice basketball players (age: 23.30 ± 1.05 yrs and ten expert basketball players (age: 22.50 ± 0.41 yrs volunteered to participate in the study. Both groups performed the modified AAHPERD Basketball Passing Test under three different testing conditions: rest, moderate intensity and high intensity total body fatigue. Fatigue intensity was established using a percentage of the maximal number of squat thrusts performed by the participant in one minute. ANOVA with repeated measures revealed a significant (F 2,36 = 5.252, p = 0.01 level of fatigue by level of skill interaction. On examination of the mean scores it is clear that following high intensity total body fatigue there is a significant detriment in the passing performance of both novice and expert basketball players when compared to their resting scores. Fundamentally however, the detrimental impact of fatigue on passing performance is not as steep in the expert players compared to the novice players. The results suggest that expert or skilled players are better able to cope with both moderate and high intensity fatigue conditions and maintain a higher level of performance when compared to novice players. The findings of this research therefore, suggest the need for trainers and conditioning coaches in basketball to include moderate, but particularly high intensity exercise into their skills sessions. This specific training may enable players at all levels of the game to better cope with the demands of the game on court and maintain a higher standard of play

  12. The use of gamma-H2AX as a biodosimeter for total-body radiation exposure in non-human primates.

    Directory of Open Access Journals (Sweden)

    Christophe E Redon

    2010-11-01

    Full Text Available There is a crucial shortage of methods capable of determining the extent of accidental exposures of human beings to ionizing radiation. However, knowledge of individual exposures is essential for early triage during radiological incidents to provide optimum possible life-sparing medical procedures to each person.We evaluated immunocytofluorescence-based quantitation of γ-H2AX foci as a biodosimeter of total-body radiation exposure ((60Co γ-rays in a rhesus macaque (Macaca mulatta model. Peripheral blood lymphocytes and plucked hairs were collected from 4 cohorts of macaques receiving total body irradiation doses ranging from 1 Gy to 8.5 Gy. Each cohort consisted of 6 experimental and 2 control animals. Numbers of residual γ-H2AX foci were proportional to initial irradiation doses and statistically significant responses were obtained until 1 day after 1 Gy, 4 days after 3.5 and 6.5 Gy, and 14 days after 8.5 Gy in lymphocytes and until 1 day after 1 Gy, at least 2 days after 3.5 and 6.5 Gy, and 9 days after 8.5 Gy in plucked hairs.These findings indicate that quantitation of γ-H2AX foci may make a robust biodosimeter for analyzing total-body exposure to ionizing radiation in humans. This tool would help clinicians prescribe appropriate types of medical intervention for optimal individual outcome. These results also demonstrate that the use of a high throughput γ-H2AX biodosimeter would be useful for days post-exposure in applications like large-scale radiological events or radiation therapy. In addition, this study validates a possibility to use plucked hair in future clinical trials investigating genotoxic effects of drugs and radiation treatments.

  13. Unscheduled DNA synthesis in spleen cells of mice exposed to low doses of total body irradiation

    International Nuclear Information System (INIS)

    Tuschl, H.; Kovac, R.; Hruby, E.

    1983-07-01

    Unscheduled DNA synthesis was induced by UV irradiation of spleen cells obtained from C 57 Bl mice after repeated total body irradiation of 0.05 Gy 60 Co (0.00125 Gy/mice) and determined autoradiographically. An enhancement in the ability for repair of UV induced DNA lesions was observed in cells of gamma irradiated animals. While the amount of 3 H-thymidine incorporated per cell was increased, the percentage of labeled cells remained unchanged. The present results are compared with previous data on low dose radiation exposure in men. (Author) [de

  14. Clinical responses after total body irradiation by over permissible dose of γ-rays in one time

    International Nuclear Information System (INIS)

    Jiang Benrong; Wang Guilin; Liu Huilan; Tang Xingsheng; Ai Huisheng

    1990-01-01

    The clinical responses of patients after total body over permissilbe dose γ-ray irradiation were observed and analysed. The results showed: when the dose was above 5 cGy, there was some immunological depression, but no significant change in hematopoietic functions. 5 cases showed some transient changes of ECG, perhaps due to vagotonia caused by psychological imbalance, One case vomitted 3-4 times after 28 cGy irradiation, this suggested that a few times of vomitting had no significance in the estimation of the irradiated dose and the whole clinical manifestations must be concretely analysed

  15. Assessment of body fat in the pony: part I. Relationships between the anatomical distribution of adipose tissue, body composition and body condition.

    Science.gov (United States)

    Dugdale, A H A; Curtis, G C; Harris, P A; Argo, C Mc

    2011-09-01

    Evaluation of equine body fat content is important for nutritional and clinical purposes. However, our understanding of total body fat and its regional distribution in the body is sparse. Currently, body fat evaluation relies on the subjective assessment of body condition score (BCS), which has never been validated against 'gold standard' chemical analysis or dissection measurements in ponies. To define the relationships between subjective (BCS), objective (morphometric) indices of body fat and 'gold standard' measurements of actual body composition. BCS and morphometry offer valid, noninvasive methods for determination of body fat in equids. Seven mature (mean ± s.e. 13 ± 3 years, 212 ± 14 kg, BCS 1.25-7/9), Welsh Mountain pony mares, destined for euthanasia (for nonresearch purposes), were used. For all ponies, body mass (BM), BCS and various morphometric measurements were recorded. Following euthanasia, all ponies were systematically dissected. Discrete white adipose tissue (WAT) depots were independently described. Gross, body chemical composition was determined by proximate analyses. Total somatic soft tissues increased linearly (r(2) = 1.00), whereas body WAT content (1-26% live BM) increased exponentially (r(2) = 0.96), with BCS. WAT was equally distributed between internal and external sites in all animals irrespective of BCS. Nuchal fat was a poor predictor of total WAT (r(2) = 0.66). Periorbital WAT did not alter with BCS (r(2) = 0.01). Heart girth:withers height and ultrasonic retroperitoneal fat depth were closely associated with total, chemically-extracted lipid which comprised 1-29% live BM (r(2) = 0.91 and 0.88, respectively). The exponential relationship between BCS and total body WAT/lipid suggests that BCS is unlikely to be a sensitive index of body fat for animals in moderate-obese states. Morphometric measurements (body girths and retroperitonel fat depth) may be useful to augment subjective BCS systems. © 2011 EVJ Ltd.

  16. The Association of Serum Total Peptide YY (PYY) with Obesity and Body Fat Measures in the CODING Study.

    Science.gov (United States)

    Cahill, Farrell; Ji, Yunqi; Wadden, Danny; Amini, Peyvand; Randell, Edward; Vasdev, Sudesh; Gulliver, Wayne; Sun, Guang

    2014-01-01

    PYY is an appetite suppressing hormone. Low circulating PYY has been linked to greater BMI. However data is controversial and this association has not been verified in large human populations. The purpose of this study was to investigate if fasting serum total PYY is associated with obesity status and/or adiposity at the population level. A total of 2094 subjects (Male-523, Female-1571) participated in this investigation. Total PYY was measured in fasting serum by enzyme-linked immunosorbent assay. Obesity status (NW-normal-weight, OW-overweight and OB-obese) was determined by the Bray Criteria according to body fat percentage measured by dual-energy x-ray absorptiometry and the WHO criteria according to BMI. One-way ANOVA and multiple regression was used to assess the adiposity-specific association between PYY and the following; weight, BMI, waist-circumference, hip-circumference, waist-hip ratio, percent body fat (%BF), trunk fat (%TF), android fat (%AF) and gynoid fat (%GF). PYY was not significantly different among NW, OW and OB groups defined by neither %BF nor BMI for both men and women. However among women, fasting PYY was positively associated with adiposity measures. Women with the highest (Top 33%) waist-circumference, %BF and %TF had significantly higher PYY (10.5%, 8.3% and 9.2% respectively) than women with the lowest (Bottom 33%). Age, smoking, medication use and menopause were all positively associated with PYY levels in women but not in men. To our knowledge this is the largest population based study, with the most comprehensive analysis and measures of confounding factors, to explore the relationship of circulating PYY with obesity. Contrary to initial findings in the literature we discovered that PYY was positively associated with body fat measures (waist-circumference, %BF and %TF) in women. Although the effect size of the positive association of PYY with obesity in women is small, and potentially negligible, it may in fact represent a protective

  17. Electron correlation in molecules: concurrent computation Many-Body Perturbation Theory (ccMBPT) calculations using macrotasking on the NEC SX-3/44 computer

    International Nuclear Information System (INIS)

    Moncrieff, D.; Wilson, S.

    1992-06-01

    The ab initio determination of the electronic structure of molecules is a many-fermion problem involving the approximate description of the motion of the electrons in the field of fixed nuclei. It is an area of research which demands considerable computational resources but having enormous potential in fields as diverse as interstellar chemistry and drug design, catalysis and solid state chemistry, molecular biology and environmental chemistry. Electronic structure calculations almost invariably divide into two main stages: the approximate solution of an independent electron model, in which each electron moves in the average field created by the other electrons in the system, and then, the more computationally demanding determination of a series of corrections to this model, the electron correlation effects. The many-body perturbation theory expansion affords a systematic description of correlation effects, which leads directly to algorithms which are suitable for concurrent computation. We term this concurrent computation Many-Body Perturbation Theory (ccMBPT). The use of a dynamic load balancing technique on the NEC SX-3/44 computer in electron correlation calculations is investigated for the calculation of the most demanding energy component in the most accurate of contemporary ab initio studies. An application to the ground state of the nitrogen molecule is described. We also briefly discuss the extent to which the calculation of the dominant corrections to such studies can be rendered computationally tractable by exploiting both the vector processing and parallel processor capabilities of the NEC SX-3/44 computer. (author)

  18. Comparison of total body irradiation-based or non-total body irradiation-based conditioning regimens for allogeneic stem cell transplantation in pediatric leukemia patients

    Directory of Open Access Journals (Sweden)

    Sang Jeong Kim

    2010-04-01

    Full Text Available Purpose : This study aims to compare the outcome of total body irradiation (TBI- or non-TBI-containing conditioning regimens for leukemia in children. Methods : We retrospectively evaluated 77 children conditioned with TBI (n=40 or non-TBI (n=37 regimens, transplanted at Chonnam National University Hospital between January 1996 and December 2007. The type of transplantation, disease status at the time of transplant, conditioning regimen, engraftment kinetics, development of graft-versus-host disease (GVHD, complications, cause of deaths, overall survival (OS, and event-free survival (EFS were compared between the 2 groups. Results : Among 34 patients with acute lymphoblastic leukemia (ALL, 28 (82.4% were in the TBI group, while 72.7% (24/33 of patients with myeloid leukemia were in the non-TBI group. Although the 5-year EFS of the 2 groups was similar for all patients (62% vs 63%, the TBI group showed a better 5-year EFS than the non-TBI group when only ALL patients were analyzed (65% vs 17%; P =0.005. In acute myelogenous leukemia patients, the non-TBI group had better survival tendency (73% vs 38%; P=0.089. The incidence of GVHD, engraftment, survival, cause of death, and late complications was not different between the 2 groups. Conclusion : The TBI and non-TBI groups showed comparable results, but the TBI group showed a significantly higher 5-year EFS than the non-TBI group in ALL patients. Further prospective, randomized controlled studies involving larger number of patients are needed to assess the late-onset complications and to compare the socioeconomic quality of life.

  19. [Total body composition in adult patients with growth hormone deficiency before and after its administration].

    Science.gov (United States)

    Weiss, V; Krsek, M; Marek, J; Stĕpán, J; Malík, J

    2003-08-01

    Effect of growth hormone (GH) on the growth and development of children is generally known. Effects of GH in adults are favorable, though. The aim of the work was to verify effects of GH administration on body composition in adult patients with GH deficit (GHD). The authors examined 15 adult patients with GHD originated in 13 of them in adulthood and in two of them in childhood. Their mean age was 43.9 +/- 11.3 years, the mean body mass was 80.0 +/- 15.2 kg. The GH deficit was verified by the stimulation insulin tolerance test. For the period of 12 months, they were subcutaneously administered recombinant human GH in a substitution dose of 0.5 to 1.5 IU/m2 body surface/day. A stable substitution of the hormone was applied for the period of at least six months in all these patients provided any deficit of other hormones had not been demonstrated. The examination by whole-body dosimeter Lunar DPX-L was made in the patients before the GH treatment began and after 12 months of therapy. It enabled to determine the amount of lean body mass (LBM) and fatty mass. After 12 months of GH treatment the mean level of insulin-like growth factor (IGF-I) was increased (P = 0.002). A statistically significant increase of total LBM (48.6 +/- 9.8 vs. 50.8 +/- 9.9 kg, P = 0.004) developed, the fatty mass did not change. Nine of these 15 patients were further followed and the administration of GH proceeded for six months. The densitometric examination was repeated, but no change of LBM was observed. The administration of GH was halted and after the period of 12 months the whole-body densitometric examination was done. The increase of LBM lasted. The amount of fat mass did not change, a decrease of fatty mass was observed after the GH administration ended. After 12 months of GH treatment there was also an increase of maximal output reached on bicycle ergometer (157.3 +/- 34.2 vs. 197.5 +/- 68.1 W, P = 0.006). A positive correlation between LBM and maximal output reached on bicycle

  20. The carcinogenic risk of high dose total body irradiation in non-human primates

    International Nuclear Information System (INIS)

    Broerse, J.J.; Bartstra, R.W.; Bekkum, D.W. van; Hage, M.H. van der; Zurcher, C.; Zwieten, M.J. van; Hollander, C.F.

    2000-01-01

    High dose total body irradiation (TBI) in combination with chemotherapy, followed by rescue with bone marrow transplantation (BMT), is increasingly used for the treatment of haematological malignancies. With the increasing success of this treatment and its current introduction for treating refractory autoimmune diseases the risk of radiation carcinogenesis is of growing concern. Studies on turnout induction in non-human primates are of relevance in this context since the response of this species to radiation does not differ much from that in man. Since the early sixties, studies have been performed on acute effects in Rhesus monkeys and the protective action of bone marrow transplantation after irradiation with X-rays (average total body dose 6.8 Gy) and fission neutrons (average dose 3.4 Gy). Of those monkeys, which were irradiated and reconstituted with autologous bone marrow, 20 animals in the X-irradiated group and nine animals in the neutron group survived more than 3 years. A group of 21 non-irradiated Rhesus monkeys of a comparable age distribution served as controls. All animals were regularly screened for the occurrence of neoplasms. Complete necropsies were performed after natural death or euthanasia. At post-irradiation intervals of 4-21 years an appreciable number of tumours was observed. In the neutron irradiated group eight out of nine animals died with one or more malignant tumours. In the X-irradiated group this fraction was 10 out of 20. The tumours in the control group, in seven out of the 21 animals, appeared at much older a-e compared with those in the irradiated cohorts. The histogenesis of the tumours was diverse with a preponderance of renal carcinoma, sarcomas among which osteosarcormas, and malignant glomus tumours in the irradiated groups. When corrected for competing risks, the carcinogenic risk of TBI in the Rhesus monkeys is similar to that derived from the studies of the Japanese atomic bomb survivors. The increase of the risk by a

  1. Blood volume, blood pressure and total body sodium: internal signalling and output control

    DEFF Research Database (Denmark)

    Bie, P

    2009-01-01

    Total body sodium and arterial blood pressure (ABP) are mutually dependent variables regulated by complex control systems. This review addresses the role of ABP in the normal control of sodium excretion (NaEx), and the physiological control of renin secretion. NaEx is a pivotal determinant of ABP......, and under experimental conditions, ABP is a powerful, independent controller of NaEx. Blood volume is a function of dietary salt intake; however, ABP is not, at least not in steady states. A transient increase in ABP after a step-up in sodium intake could provide a causal relationship between ABP...... and the regulation of NaEx via a hypothetical integrative control system. However, recent data show that subtle sodium loading (simulating salty meals) causes robust natriuresis without changes in ABP. Changes in ABP are not necessary for natriuresis. Normal sodium excretion is not regulated by pressure. Plasma...

  2. The influence of selenium status on body composition, oxidative DNA damage and total antioxidant capacity in newly diagnosed type 2 diabetes mellitus: A case-control study.

    Science.gov (United States)

    Othman, Fatimah Binti; Mohamed, Hamid Jan Bin Jan; Sirajudeen, K N S; Noh, Mohd Fairulnizal B Md; Rajab, Nor Fadilah

    2017-09-01

    Selenium is involved in the complex system of defense against oxidative stress in diabetes through its biological function of selenoproteins and the antioxidant enzyme. A case-control study was carried out to determine the association of plasma selenium with oxidative stress and body composition status presented in Type 2 Diabetes Mellitus (T2DM) patient and healthy control. This study involved 82 newly diagnosed T2DM patients and 82 healthy controls. Plasma selenium status was determined with Graphite Furnace Atomic Absorption Spectrometry. Body Mass Index, total body fat and visceral fat was assessed for body composition using Body Composition Analyzer (TANITA). Oxidative DNA damage and total antioxidant capacity were determined for oxidative stress biomarker status. In age, gender and BMI adjustment, no significant difference of plasma selenium level between T2DM and healthy controls was observed. There was as a significant difference of Oxidative DNA damage and total antioxidant capacity between T2DM patients and healthy controls with tail DNA% 20.62 [95% CI: 19.71,21.49] (T2DM), 17.67 [95% CI: 16.87,18.56] (control); log tail moment 0.41[95% CI: 0.30,0.52] (T2DM), 0.41[95% CI: 0.30,0.52] (control); total antioxidant capacity 0.56 [95% CI: 0.54,0.58] (T2DM), 0.60 [95% CI: 0.57,0.62] (control). Waist circumference, BMI, visceral fat, body fat and oxidative DNA damage in the T2DM group were significantly lower in the first plasma selenium tertile (38.65-80.90μg/L) compared to the second (80.91-98.20μg/L) and the third selenium tertiles (98.21-158.20μg/L). A similar trend, but not statistically significant, was observed in the control group. Copyright © 2016 Elsevier GmbH. All rights reserved.

  3. Effective one-body potential of DFT plus correlated kinetic energy density for two-electron spherical model atoms

    International Nuclear Information System (INIS)

    March, N.H.; Ludena, Eduardo V.

    2004-01-01

    For three model problems concerning two-electron spin-compensated ground states with spherical density, the third-order linear homogeneous differential equation constructed for the determination of ρ(r) is used here in conjunction with the von Weizsacker functional to characterize the one-body potential of density functional theory (DFT). Correlated von Weizsacker-type terms are compared to the exact DFT functional

  4. Use of i.v. radionuclide total body arteriography to evaluate arterial bypass shunts--a new method--a review of several cases

    International Nuclear Information System (INIS)

    Yang, D.C.; Jain, C.U.; Patel, D.; Gould, L.; Schaefer, H.; Maghazeh, P.; Giovanniello, J.

    1990-01-01

    Currently, Doppler ultrasound and contrast angiography are the main imaging procedures being used to evaluate arterial bypass shunts. IV radionuclide total body arteriography (TBA) is another useful imaging procedure for evaluation of bypass shunts. The authors reviewed 33 patients, 19 women and 14 men, ranging in age from forty-three to eighty-five, who had TBA done after arterial bypass surgery. Ten patients had multiple shunts and 5 had multiple follow-up studies. In total there were 80 shunts, including 43 femoropopliteal, 16 axillofemoral, 1 axillopopliteal, 13 crossover femorofemoral, and 7 aortofemoral shunts. Sixty-two of the 80 shunts were patent, 14 were occluded, and 4 had partial occlusion. The results were confirmed by Doppler studies, contrast angiograms, and/or surgical exploration without false positives or false negatives. Since the radiotracer used was 99mTc-labeled red blood cells, a MUGA study can also be performed immediately following TBA in the same injection. Twenty-eight patients had gated cardiac blood pool studies (MUGA) done; 16 had abnormal wall motion and diminished ventricular function. TBA requires only a single IV injection of radiotracer (less than 1 cc) in the upper limb. The imaging times for total body arterial and perfusion images are seventy seconds and five minutes respectively. Both total body arterial and perfusion images clearly demonstrated the entire course of shunts (single or multiple); underlying and coexisting arterial abnormalities, e g, occlusive disease (27 patients), or aneurysm (3 patients); and related perfusion changes in the extremities. TBA has unique features. It permits a complete, excellent visualization of the bypass graft without the hazard of contrast media injection. It is a simple and a virtually noninvasive procedure, particularly useful for preoperative workups and postoperative follow-ups

  5. Impact of dietary vitamin A interventions on total body stores in Thai lactating women

    International Nuclear Information System (INIS)

    Wasanwisut, E.; West, K.P.

    1997-01-01

    Vitamin A deficiency (VAD) is increasingly being recognized as a public health problem among pregnant and lactating women in developing countries. This proposed study will be a randomized trial to evaluate the efficacy of consuming provitamin A-rich foods in one prepared, on-site meal per weekday for 3 months on total body vitamin A stores and other aspects of vitamin A status in marginally nourished lactating women in rural Northeast Thailand. Approximately 400 lactating women, 2-18 months post-partum, will be screened in the population for marginal vitamin A status by a tier of indicators beginning from low intake or history of night blindness or impaired dark adaptability followed by low serum retinol. Assuming a prevalence of low serum retinol of ∼20%, 90 women will be identified and recruited, matched by serum retinol and month post-partum and randomized in a block fashion into three groups to receive daily cooked (fat-added) meal and snack with (1) dark green leafy and yellow/orange vegetables and fruits, (2) beta-carotene- enriched rice chips and (3) non-enriched rice chips. Groups 1 and 2 will receive ∼3.6 mg of beta-carotene per day. Prior to and following the intervention hepatic vitamin A reserves will be estimated by isotopic dilution techniques and other indicators of vitamin A status. In addition, serum C-reactive protein and maternal anthropometry will be measured. Food consumption data based on 24-hour recall for 3 randomized days will be collected every 2 weeks to assess routine intakes of vitamin A, fat and other nutrients. Morbidity will be monitored on a weekly basis throughout the study. Between-group comparisons will provide a basis for (1) estimating the adequacy of local diets to improve or maintain total body stores of vitamin A in women during lactation and (2) assessing the validity and responsiveness of widely used measures of vitamin A status in this high-risk group

  6. The effect of low-dose total body irradiation on tumor control

    International Nuclear Information System (INIS)

    Sakamoto, Kiyohiko; Miyamoto, Miyako; Watabe, Nobuyuki.

    1987-01-01

    Total body irradiation (TBI) is considered to bring about an immunosuppressive effect on an organism, on the basis of data obtained from sublethal doses of TBI. However, there are no data on how low-dose TBI affects an organism. Over the last five years, we have been studying the effects of low-dose TBI on normal or tumor-bearing mice and the immunological background of these effects. In experimental studies, an increase in the TD50 value (the number of cells required for a tumor incidence of 50 %) in mice exposed to 10 rad was recognized and showed a remarkable increase at 6 hours to 15 hours after irradiation. TBI of 10 rad also showed an enhancement effect on tumor cell killing when given 12 hours before local tumor irradiation. In order to clarify the mechanism of this kind of effect, some immunological studies were performed using several immunological procedures, and the results suggested that 10 rad of TBI caused increasing tumor immunity in irradiated mice. Clinical trials in some patients with advanced tumors are now being undertaken on the basis of these experimental data, and the effect of TBI on tumor control appears promising, although it is too early to draw conclusions. (author)

  7. Total body irradiation therapy for thymectomized myasthenic patients and immunological evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Yamanaka, Nobukazu; Tanaka, Masayuki; Kurihara, Teruyuki (Miyazaki Medical College (Japan))

    1983-06-01

    Three patients with intractable myasthenia gravis (MG) were treated with total body irradiation (TBI). All the three patients had been unstable after extended thymectomy and poorly responding to prednisolone therapy. Radiation therapy consisted of 10 doses of 10 rads/day given over five weeks. After the radiation therapy the three patients improved clinically, and an objective parameter, area of M-waves also improved. No significant side effects were noted. TBI therapy can be considered as a safe method to induce selective reduction of circulating lymphocytes. This was indeed achieved, as evidenced by a drop of the lymphocyte counts to the levels of 20-40 % of the pretreatment level. The effects were persistent over twelve weeks. Early radiosensitivity of B lymphocytes were recognized. The levels of T..gamma.. cells were low before TBI therapy, increasing gradually during TBI therapy and returned to normal range after twelve weeks. Serum anti-AChR antibody titers decreased in all the cases, but it was impossible to determine whether the decrement was due to the therapy or natural course after thymectomy. Two of our three cases had a significant percentage decrement of the titers after TBI therapy. We suggest that TBI therapy is a safe method of immunosupperssive treatment for the myasthenic patients after thymectomy.

  8. Total body irradiation therapy for thymectomized myasthenic patients and immunological evaluations

    International Nuclear Information System (INIS)

    Yamanaka, Nobukazu; Tanaka, Masayuki; Kurihara, Teruyuki

    1983-01-01

    Three patients with intractable myasthenia gravis (MG) were treated with total body irradiation (TBI). All the three patients had been unstable after extended thymectomy and poorly responding to prednisolone therapy. Radiation therapy consisted of 10 doses of 10 rads/day given over five weeks. After the radiation therapy the three patients improved clinically, and an objective parameter, area of M-waves also improved. No significant side effects were noted. TBI therapy can be considered as a safe method to induce selective reduction of circulating lymphocytes. This was indeed achieved, as evidenced by a drop of the lymphocyte counts to the levels of 20-40 % of the pretreatment level. The effects were persistent over twelve weeks. Early radiosensitivity of B lymphocytes were recognized. The levels of Tγ cells were low before TBI therapy, increasing gradually during TBI therapy and returned to normal range after twelve weeks. Serum anti-AChR antibody titers decreased in all the cases, but it was impossible to determine whether the decrement was due to the therapy or natural course after thymectomy. Tow of our three cases had a significant percentage decrement of the titers after TBI therapy. We suggest that TBI therapy is a safe method of immunosupperssive treatment for the myasthenic patients after thymectomy. (author)

  9. Many-body Green’s function theory for electron-phonon interactions: Ground state properties of the Holstein dimer

    International Nuclear Information System (INIS)

    Säkkinen, Niko; Leeuwen, Robert van; Peng, Yang; Appel, Heiko

    2015-01-01

    We study ground-state properties of a two-site, two-electron Holstein model describing two molecules coupled indirectly via electron-phonon interaction by using both exact diagonalization and self-consistent diagrammatic many-body perturbation theory. The Hartree and self-consistent Born approximations used in the present work are studied at different levels of self-consistency. The governing equations are shown to exhibit multiple solutions when the electron-phonon interaction is sufficiently strong, whereas at smaller interactions, only a single solution is found. The additional solutions at larger electron-phonon couplings correspond to symmetry-broken states with inhomogeneous electron densities. A comparison to exact results indicates that this symmetry breaking is strongly correlated with the formation of a bipolaron state in which the two electrons prefer to reside on the same molecule. The results further show that the Hartree and partially self-consistent Born solutions obtained by enforcing symmetry do not compare well with exact energetics, while the fully self-consistent Born approximation improves the qualitative and quantitative agreement with exact results in the same symmetric case. This together with a presented natural occupation number analysis supports the conclusion that the fully self-consistent approximation describes partially the bipolaron crossover. These results contribute to better understanding how these approximations cope with the strong localizing effect of the electron-phonon interaction

  10. Differential and total cross sections for the ionization of water molecule by electron impact

    International Nuclear Information System (INIS)

    Houamer, S.; Dal Cappello, C.; Mansouri, A.

    2007-01-01

    A theoretical approach is presented to calculate multiply differential and total cross sections of the ionization of H 2 O molecule in the vapour phase. The wave function of the target is described by molecular orbitals consisting of a linear combination of slater type atomic orbitals centered on the heaviest atom which is the oxygen atom in this case. The calculations are carried out in the first Born approximation where the projectile is described by a plane wave while the ejected electron is described by a coulomb wave taking into account its interaction with the residual ion. The spherical average over the Euler solid angle due to the randomly oriented gaseous target molecule is carried out analytically using the rotation matrix properties. The differential and total cross sections are thus evaluated without any special difficulty and compared with experiments and distorted wave calculations. Fair agreements are observed

  11. Role of total body irradiation as based on the comparison of preparation regimens for allogeneic bone marrow transplantation for acute leukemia in first complete remission

    International Nuclear Information System (INIS)

    Inoue, T.; Ikeda, H.; Yamazaki, H.; Tang, J.T.; Song, C.; Teshima, T.; Murayama, S.; Ohtani, M.; Shibata, H.; Masaoka, T.

    1993-01-01

    The role of total body irradiation (TBI) for allogeneic bone marrow transplantation (BMT) for acute leukemia in first complete remission was reevaluated in this study. From Japanese BMT Registry, data of 123 acute leukemia patients in first complete remission who underwent allogeneic bone marrow transplantation in 22 hospitals between 1988 and 1990 were available for the present comparative study of preparation regimens with or without total body irradiation. Two-year survivals were 77% and 51% in the TBI containing regimen group and in the non-TBI regimen group, respectively (p=0.0010). Corresponding two-year relapse rates were 16% and 37%, respectively (p=0.0197). Corresponding probabilities of developing interstitial pneumonitis were 21% and 24%, respectively (p=0.8127). The analysis of causes of death indicated that non-TBI regimen increased the incidence of septicemia and lethal organ failures, such as liver, heart, lung and other multiple sites. It was emphasized that an additional role of total body irradiation was to disperse the treatment-related toxicity in allogeneic bone marrow transplantation for acute leukemia. (orig.) [de

  12. Effect of selective and nonselective beta-blockers on resting energy production rate and total body substrate utilization in chronic heart failure.

    Science.gov (United States)

    Podbregar, Matej; Voga, Gorazd

    2002-12-01

    In chronic heart failure (CHF) beta-blockers reduce myocardial oxygen consumption and improve myocardial efficiency by shifting myocardial substrate utilization from increased free fatty acid oxidation to increased glucose oxidation. The effect of selective and nonselective beta-blockers on total body resting energy production rate (EPR) and substrate utilization is not known. Twenty-six noncachectic patients with moderately severe heart failure (New York Heart Association class II or III, left ventricular ejection fraction < 0.40) were treated with carvedilol (37.5 +/- 13.5 mg/12 h) or bisoprolol (5.4 +/- 3.0 mg/d) for 6 months. Indirect calorimetry was performed before and after 6 months of treatment. Resting EPR was decreased in carvedilol (5.021 +/- 0.803 to 4.552 +/- 0.615 kJ/min, P <.001) and bisoprolol group (5.230 +/- 0.828 to 4.978 +/- 0.640 kJ/min, P <.05; nonsignificant difference between groups). Lipid oxidation rate decreased in carvedilol and remained unchanged in bisoprolol group (2.4 +/- 1.4 to 1.5 +/- 0.9 mg m(2)/kg min versus 2.7 +/- 1.1 to 2.5 +/- 1.1 mg m(2)/kg min, P <.05). Glucose oxidation rate was increased only in carvedilol (2.6 +/- 1.4 to 4.4 +/- 1.6 mg m(2)/kg min, P <.05), but did not change in bisoprolol group. Both selective and nonselective beta-blockers reduce total body resting EPR in noncachectic CHF patients. Carvedilol compared to bisoprolol shifts total body substrate utilization from lipid to glucose oxidation.

  13. Few-body correlations in many-body physics

    Energy Technology Data Exchange (ETDEWEB)

    Barth, Marcus

    2015-12-01

    In this thesis, various systems are analyzed in parameter regimes where the few-body aspects are dominant over the many-body behavior. Using the Operator Product Expansion from Quantum Field Theory, exact relations for observables of the electron gas as well as two-dimensional Fermi gases are derived. In addition, properties of both two-dimensional and three-dimensional cold quantum gases at small to moderate degeneracy are determined by means of a diagrammatic virial expansion.

  14. The relationships among total body fat, bone mineral content and bone marrow adipose tissue in early-pubertal girls

    OpenAIRE

    L Newton, Anna; J Hanks, Lynae; Davis, Michelle; Casazza, Krista

    2013-01-01

    Investigation of the physiologic relevance of bone marrow adipose tissue (BMAT) during growth may promote understanding of the bone-fat axis and confluence with metabolic factors. The objective of this pilot investigation was two-fold: (1) to evaluate the relationships among total body fat, bone mineral content (BMC) and femoral BMAT during childhood and underlying metabolic determinants and (2) to determine if the relationships differ by race. Participants included white and non-Hispanic bla...

  15. Body composition changes after totally laparoscopic distal gastrectomy with delta-shaped anastomosis: a comparison with conventional Billroth I anastomosis.

    Science.gov (United States)

    Park, Ki Bum; Kwon, Oh Kyoung; Yu, Wansik; Jang, Byeong-Churl

    2016-10-01

    The purpose of this study was to compare body composition changes of patients undergoing totally laparoscopic distal gastrectomy (TLDG) with delta-shaped anastomosis (DSA) versus conventional laparoscopic distal gastrectomy (CLDG). Data from gastric cancer patients who underwent laparoscopic distal gastrectomy for histologically proven gastric cancer in KNUMC from January 2013 to May 2014 were collected and reviewed. We examined 85 consecutive patients undergoing TLDG or CLDG: 41 patients underwent TLDG and 44 patients underwent CLDG. Body composition was assessed by segmental multifrequency bioelectrical impedance analysis. We compared the changes in nutritional parameters and body composition from preoperative status between the two groups at postoperative 6 and 12 months. All of the postoperative changes in the body composition and nutritional indices were similar between the two groups with the exception of visceral fat areas (VFAs) and albumin levels. VFAs increased at 6 months postoperatively in the TLDG group and a significant difference was shown at 12 months postoperatively between the TLDG and CLDG groups (86.7 ± 22.8 and 74.7 ± 21.9 cm(2), respectively, P body composition seemed comparable to those of CLDG. Six months postoperatively, VFAs and albumin levels were recovered in the TLDG group but not in the CLDG group. Thus, TLDG seems to be a novel surgical method.

  16. Vibrational enhancement of total breakup cross sections

    International Nuclear Information System (INIS)

    Haftel, M.I.; Lim, T.K.

    1984-01-01

    This paper considers the role of multi-two-body bound states, namely vibrational excitations, on total three-body breakup cross-sections. Total cross-sections are usually easy to measure, and they play a fundamental role in chemical kinetics. (orig.)

  17. Electron distribution function in electron-beam-excited plasmas

    International Nuclear Information System (INIS)

    Brau, C.A.

    1976-01-01

    In monatomic plasmas excited by high-intensity relativistic electron beams, the electron secondary distribution function is dominated by elastic electron-electron collisions at low electron energies and by inelastic electron-atom collisions at high electron energies (above the excitation threshold). Under these conditions, the total rate of excitation by inelastic collisions is limited by the rate at which electron-electron collisions relax the distribution function in the neighborhood of the excitation threshold. To describe this effect quantitatively, an approximate analytic solution of the electron Boltzmann equation is obtained, including both electron-electron and inelastic collisions. The result provides a simple formula for the total rate of excitation

  18. Many-body correlation effects in the spatially separated electron and hole layers in the coupled quantum wells

    Energy Technology Data Exchange (ETDEWEB)

    Babichenko, V.S. [RRC Kurchatov Institute, Kurchatov Sq., 1, 123182 Moscow (Russian Federation); Polishchuk, I.Ya., E-mail: iyppolishchuk@gmail.com [RRC Kurchatov Institute, Kurchatov Sq., 1, 123182 Moscow (Russian Federation); Moscow Institute of Physics and Technology, 141700, 9, Institutskii per., Dolgoprudny, Moscow Region (Russian Federation)

    2014-11-15

    The many-body correlation effects in the spatially separated electron and hole layers in the coupled quantum wells are investigated. A special case of the many-component electron–hole system is considered. It is shown that if the hole mass is much greater than the electron mass, the negative correlation energy is mainly determined by the holes. The ground state of the system is found to be the 2D electron–hole liquid with the energy smaller than the exciton phase. It is shown that the system decays into the spatially separated neutral electron–hole drops if the initially created charge density in the layers is smaller than the certain critical value n{sub eq}.

  19. On the normalization of total wave function of the system of an atom and a colliding electron

    International Nuclear Information System (INIS)

    Nashlenas, Eh.P.; Trinkunas, G.P.

    1976-01-01

    The scattering of an electron by an atom is considered which causes an excitation of fine structure levels. For this purpose the wave function of a system consisting of an atom and an uncoupled electron is constructed. Boundary conditions formulated in the form of an asymptotic expression are taken into account for such a function by means of scattering amplitudes. To determine scattering amplitudes it is suggested to make use of the condition of wave function normalization into the Dirac delta function. After certain mathematical transformations the unknown relations between the scattering amplitudes are obtained. The special cases of the relations obtained are discussed. When quantum numbers of the wave functions coincide, the resulting relations express the equality of fluxes of converging and diverging waves for a certain value of the total angular momentum. In the limiting case when there are no electrons in an atom (it corresponds to elastic scattering of an electron on a potential) the relations obtained express the unitarity conditions of the scattering matrix

  20. Electron correlations in single-electron capture from helium by fast protons and α particles

    International Nuclear Information System (INIS)

    Mancev, Ivan; Milojevic, Nenad

    2010-01-01

    Single-electron capture from heliumlike atomic systems by bare projectiles is investigated by means of the four-body boundary-corrected first Born approximation (CB1-4B). The effect of the dynamic electron correlation is explicitly taken into account through the complete perturbation potential. The quantum-mechanical post and prior transition amplitudes for single charge exchange encompassing symmetric and/or asymmetric collisions are derived in terms of two-dimensional real integrals in the case of the prior form and five-dimensional quadratures for the post form. An illustrative computation is performed for single-electron capture from helium by protons and α particles at intermediate and high impact energies. The role of dynamic correlations is examined as a function of increased projectile energy. The validity and utility of the proposed CB1-4B method is critically assessed in comparison with the existing experimental data for total cross sections, and excellent agreement is obtained.

  1. The effects of different schedules of total-body irradiation in heterotopic vascularized bone transplantation. An experimental study in the Lewis rat

    International Nuclear Information System (INIS)

    Gonzalez del Pino, J.; Benito, M.; Randolph, M.A.; Weiland, A.J.

    1990-01-01

    To evaluate the effects of irradiation on heterotopically placed vascularized knee isografts, a single dose of 10 Gy of total-body irradiation was given to Lewis donor rats. Irradiation was delivered either 2 or 6 days prior to harvesting or subsequent transplantation, and evaluated at 1, 2, and 4 weeks after grafting. Irradiation caused endothelial depopulation of the graft artery, although vascular pedicle patency was maintained throughout the study. Bone graft viability and mineralization were normal. Dramatic changes in the bone marrow were seen that included an increase of its fat content (P less than 0.001), and a concomitant decrease in bone marrow-derived immunocompetent cells. These changes were more prominent in recipients of grafts from day -6 irradiated donor rats. Total-body irradiation did not prejudice the use of vascularized bone grafts, and exhibited an associated immunosuppresant effect over the vascular endothelium and bone marrow. This may be a further rational conditioning procedure to avoid recipient manipulation in vascularized bone allotransplantation

  2. Spatial correlation of the ionsphere total electron content at the equatorial anomaly crest

    International Nuclear Information System (INIS)

    Huang, Y.

    1984-01-01

    The spatial correlation of the ionospheric total electron content (TEC) at the equatorial anomaly crest was studied by recording Faraday rotation angle of the ETS-II geostationary satellite at Lunping and Kaohsiung whose subionospheric points are located at 23.0 0 N, 121.0 0 N, and 20.9 0 N, 121.1 0 E, respectively, and are about 280 km apart. The results show that the spatial correlation of TEC at the equatorial crest region is smaller than that at other places. The day-to-day variabilities of TEC differences between two subionospheric points are quite large. The day-to-day variabilities of the fountain effect seem to play an important role

  3. Experimental Investigation of Electron Cloud Containment in a Nonuniform Magnetic Field

    Science.gov (United States)

    Eninger, J. E.

    1974-01-01

    Dense clouds of electrons were generated and studied in an axisymmetric, nonuniform magnetic field created by a short solenoid. The operation of the experiment was similar to that of a low-pressure (approximately 0.000001 Torr) magnetron discharge. Discharge current characteristics are presented as a function of pressure, magnetic field strength, voltage, and cathode end-plate location. The rotation of the electron cloud is determined from the frequency of diocotron waves. In the space charge saturated regime of operation, the cloud is found to rotate as a solid body with frequency close to V sub a/phi sub a where V sub a is the anode voltage and phi suba is the total magnetic flux. This result indicates that, in regions where electrons are present, the magnetic field lines are electrostatic equipotentials (E bar, B bar = 0). Equilibrium electron density distributions suggested by this conditions are integrated with respect to total ionizing power and are found consistent with measured discharge currents.

  4. Experimental investigation of electron cloud containment in a nonuniform magnetic field

    International Nuclear Information System (INIS)

    Eninger, J.E.

    1974-05-01

    Dense clouds of electrons were generated and studied in an axisymmetric, nonuniform magnetic field created by a short solenoid. The operation of the experiment was similar to that of a low-pressure (approximately 0.000001 torr) magnetron discharge. Discharge current characteristics are presented as a function of pressure, magnetic field strength, voltage, and cathode end-plate location. The rotation of the electron cloud is determined from the frequency of diocotron waves. In the space charge saturated regime of operation, the cloud is found to rotate as a solid body with frequency close to V/sub a/phi/sub a/ where V/sub a/ is the anode voltage and phi/sub a/ is the total magnetic flux. This result indicates that, in regions where electrons are present, the magnetic field lines are electrostatic equipotentials (E bar, B bar = 0). Equilibrium electron density distributions suggested by this condition are integrated with respect to total ionizing power and are found consistent with measured discharge currents. (U.S.)

  5. Determination of lead in clay enameled by X-ray fluorescence technique in Total reflection and by Scanning Electron Microscopy

    International Nuclear Information System (INIS)

    Zarazua O, G.; Carapia M, L.

    2000-01-01

    This work has the objective of determining lead free in the glazed commercial stewing pans using the X-ray fluorescence technique in Total reflection (FRX) and the observation and semiquantitative determination of lead by Analytical Scanning Electron Microscopy (ASEM). (Author)

  6. Relative effect of radiation dose rate on hemopoietic and nonhemopoietic lethality of total-body irradiation

    International Nuclear Information System (INIS)

    Peters, L.J.; McNeill, J.; Karolis, C.; Thames, H.D. Jr.; Travis, E.L.

    1986-01-01

    Experiments were undertaken to determine the influence of dose rate on the toxicity of total-body irrdiation (TBI) with and without syngeneic bone-marrow rescue in mice. The results showed a much greater dose-rate dependence for death from nonhemopoietic toxicity than from bone-marrow ablation, with the ratio of LD 50 's increasing from 1.73 at 25 cGy/min to 2.80 at 1 cGy/min. At the higher dose rates, dose-limiting nonhemopoietic toxicity resulted from late organ injury, affecting the lungs, kidneys, and liver. At 1 cGy/min the major dose-limiting nonhemopoietic toxicity was acute gastrointestinal injury. The implications of these results in the context of TBI in preparation for bone-marrow transplantation are discussed. 15 refs., 4 figs

  7. Radiological protection in a patient during a total body irradiation procedure; Proteccion radiologica en un paciente durante un procedimiento de TBI (irradiacion de cuerpo entero)

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez O, J. O.; Hinojosa G, J.; Gomez M, E.; Balam de la Vega, J. A. [The American British Cowdray Medical Center, I. A. P., Sur 128 No. 143, Col. Americas, 01120 Mexico D. F. (Mexico); Deheza V, J. C., E-mail: johernandezo@abchospital.co [IPN, Escuela Superior de Fisica y Matematicas, Av. Luis Enrique Erro s/n, Edificio No. 9, Unidad Profesional Adolfo Lopez Mateos, Col. Lindavista, 07738 Mexico D. F. (Mexico)

    2010-09-15

    A technique used in the Service of Radiotherapy of the Cancer Center of the American British Cowdray Medical Center (ABC) for the bone marrow transplantation, is the total body irradiation. It is known that the dose calculation, for this irradiation type, is old, since the dosimetric calculation is carried out by hand and they exist infinity of techniques for the patients irradiation and different forms of protecting organs of risk, as well as a great uncertainty in the given dose. In the Cancer Center of the ABC Medical Center, was carried out an irradiation procedure to total body with the following methodology: Computerized tomography of the patient total body (two vacuum mattresses in the following positions: dorsal and lateral decubitus), where is combined the two treatment techniques anterior-posterior and bilateral, skin delineate and reference volumes, dose calculation with the planning system Xi O of CMS, dose determination using an ionization chamber and a lung phantom IMRT Thorax Phantom of the mark CIRS and dosimetry in vivo. In this work is presented the used treatment technique, the results, statistics and the actualization of the patient clinical state. (Author)

  8. Influence of electron evaporative cooling on ultracold plasma expansion

    International Nuclear Information System (INIS)

    Wilson, Truman; Chen, Wei-Ting; Roberts, Jacob

    2013-01-01

    The expansion of ultracold neutral plasmas (UCP) is driven primarily by the thermal pressure of the electron component and is therefore sensitive to the electron temperature. For typical UCP spatial extents, evaporative cooling has a significant influence on the UCP expansion rate at lower densities (less than 10 8 /cm 3 ). We studied the effect of electron evaporation in this density range. Owing to the low density, the effects of three-body recombination were negligible. We modeled the expansion by taking into account the change in electron temperature owing to evaporation as well as adiabatic expansion and found good agreement with our data. We also developed a simple model for initial evaporation over a range of ultracold plasma densities, sizes, and electron temperatures to determine over what parameter range electron evaporation is expected to have a significant effect. We also report on a signal calibration technique, which relates the signal at our detector to the total number of ions and electrons in the ultracold plasma

  9. Monte carlo efficiency calibration of a neutron generator-based total-body irradiator

    Science.gov (United States)

    The increasing prevalence of obesity world-wide has focused attention on the need for accurate body composition assessments, especially of large subjects. However, many body composition measurement systems are calibrated against a single-sized phantom, often based on the standard Reference Man mode...

  10. Analytic model of electron pulse propagation in ultrafast electron diffraction experiments

    International Nuclear Information System (INIS)

    Michalik, A.M.; Sipe, J.E.

    2006-01-01

    We present a mean-field analytic model to study the propagation of electron pulses used in ultrafast electron diffraction experiments (UED). We assume a Gaussian form to characterize the electron pulse, and derive a system of ordinary differential equations that are solved quickly and easily to give the pulse dynamics. We compare our model to an N-body numerical simulation and are able to show excellent agreement between the two result sets. This model is a convenient alternative to time consuming and computationally intense N-body simulations in exploring the dynamics of UED electron pulses, and as a tool for refining UED experimental designs

  11. Radiotherapy for ocular lesions by electron beam therapy

    International Nuclear Information System (INIS)

    Miyaishi, Kazuo

    1981-01-01

    Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The appliance of conventional X ray therapy has been gradually abandaned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973; It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, 600 rads at a time, 3600 - 4200 rads in total is applied by 8 MeV electron twice a week method. 2) For malignant melanoma, 1000 rads at a time, 4000 - 5000 rads in total is applied by 8 MeV electron twice a week method. 3) For orbitar lymphoid neoplasm, Cobalt-60 γ ray or Linac X ray is applied together with electron beam. 4) For embryonal rhabdomyosarcoma, adenoid cystic cancer etc., the therapy for whole body is necessary. 5) For benign tumors, a small dose at a time is applied for a long time. (author)

  12. 'Mini' total body irradiation and allogeneic bone marrow transplantation

    International Nuclear Information System (INIS)

    Gocheva, L.; Sergieva, K.; Koleva, I.; Avramova, V.; Vassileva, V.; Georgieva, S.; Sultanov, B.

    2006-01-01

    Full text: The total body irradiation (TBI) combined with intensive chemotherapy plays an important role in the preparation of patients for bone marrow transplantation (BMT). The first autologous BMT in Bulgaria was performed in 1997 in the Specialized Pediatric Hospital for Active Treatment (SPHAT) of oncohematological diseases. The first TBI, followed by allogeneic BMT, was carried out in 2002 in the 'Queen Giovanna' University Hospital, after which its routine application as a basic form of large field radiotherapy and a main stage of the conditioning regimen for BMT was started. Fourteen allogeneic BMTs including TBI as a basic conditioning regimen have been performed till May 2006. The objective of the present report is to present the first clinical observations in the Bulgarian oncological practice on 'mini' TBI followed by allogeneic blood stem cell transplantation. During the period October 2005 - May 2006, 'mini' TBI followed by allogeneic BMT was carried out for two patients of the age 43 and 50 years. The diagnosis of both patients was acute non-lymphoblastic leukemia, in the remission stage, after one relapse, respectively. Intensive preceding chemotherapy was applied for both patients. A conditioning regimen was applied including the fludarabine purine analogue (3 x 30 mg/m 2 ) and 200 cGy TBI. It was followed by transplantation of allogeneic cell concentrate containing 2.5 x10 6 /kg CD34+ and 4.0 x10 6 /kg CD34+ blood stem cells of partially compatible family donors (a sister and a son), which were tolerable for the patients without complications. Cyclosporine and mycophelonate mofetile were applied as post-transplantation treatment. Active antibiotic, antiviral, symptomatic and substituting therapy, as well as GvHD prophylaxis was applied for both patients. Good clinical tolerance was recorded for the applied low dose conditioning regimen. The patients were discharged within 30 days in good general condition and stable draft action, with

  13. Body composition and dietary intake in neoplasic disease

    International Nuclear Information System (INIS)

    Cohn, S.H.; Gartenhaus, W.; Vartsky, D.; Sawitsky, A.; Zanzi, I.; Vaswani, A.; Yasummure, S.; Rai, K.; Cartes, E.; Ellis, K.J.

    1981-01-01

    Changes in body composition in 37 cancer patients were studied over a period of 6 months. Initially, the patients were divided into two groups: those who lost body weight (over 10%) and those who maintained or gained body weight before the study. Analysis of body composition indicated that patients who lost body weight has caloric and protein intakes markedly below ''normal'' levels at the beginning of the study. There also appears to be a direct relationship between the protein intake and the total body potassium/total body water ratio in the cancer patients. At the end of the 6-month study, the patients were again placed into two groups on the basis of weight loss or gain (and maintenance). Changes in body composition over the period were analyzed in terms of lean body mass, its protein constituent, water, and fat. Weight loss was found to reflect primarily the loss of fat, water, lean body mass (potassium), and only to a minor extent the protein component of lean body mass (nitrogen). Further, on the basis of the values of the ratios of total body nitrogen/total body potassium/total body water, it was possible to ascertain the relative normalcy of the body tissue gained or lost in the 6-month period. The results of the study suggest that the ratio total body nitrogen/total body potassium may serve as the best indicator of recent or ongoing catabolism or anabolism of the neoplastic process. By means of the application of the techniques used for the determination of body composition, it should be possible to assess regimes of hyperalimentation of cancer patients who lose body weight

  14. Long-term results of total body irradiation in adults with acute lymphoblastic leukemia

    International Nuclear Information System (INIS)

    Marnitz, Simone; Zich, Alexander; Budach, Volker; Jahn, Ulrich; Neumann, Oliver; Martus, Peter; Arnold, Renate

    2014-01-01

    The aim of this chart review of adult patients treated for acute lymphoblastic leukemia (ALL) with total body irradiation (TBI) was to evaluate early and late toxicity and long-term outcome. A total of 110 adult patients (34 ± 12 years) with ALL underwent TBI (6 fractions of 2 Gy for a total of 12 Gy) as a part of the treatment regimen before transplantation. Treatment-related toxicity, mortality, and hematologic outcome are reported. Mean follow-up was 70 months. The 2- and 5-year leukemia-free survival rates were 78 and 72 %, respectively. In all, 29 % (32/110) patients suffered from medullary recurrence after a median time of 7 months. Gender was the only statistically significant prognostic factor in terms of overall survival in favor of female patients. Treatment-related mortality and overall survival after 2 and 5 years were 16 and 22 %, and 60 and 52.7 %, respectively. The most frequent late reaction wascGVHD of the skin (n = 33, 30 %). In addition, 15.5 % (17/110 patients) suffered pulmonary symptoms, and 6 patients developed lung fibrosis. Eyes were frequently affected by the radiation (31/110 = 28 %); 12 of 110 patients (11 %) presented with symptoms from osteoporosis, 5 of 110 patients (4.5 %) developed hypothyreosis and 2 patients diabetes mellitus. Of the male patients, 11 % reported erectile dysfunction or loss of libido, while 2 of 36 women reported menopausal syndrome at the mean time of 28 months after treatment with requirement for substitution. No women became pregnant after treatment. No acute or late cardiac toxicities were documented in our patients. No secondary malignancies were documented. Although hematologic outcome was in the upper range of that reported in the literature, treatment-related mortality (TRM) and medullary recurrences remain a challenge. Sophisticated radiation techniques allow for decreasing toxicity to certain organs and/or dose escalation to the bone marrow in highly selected patients in order to improve therapeutic

  15. Electron induced break-up of helium. Benchmark experiments on a dynamical four-body Coulomb system

    International Nuclear Information System (INIS)

    Duerr, M.

    2006-01-01

    This work presents an experimental study of fragmentation of helium by electron impact, in which absolute fully differential cross sections for single ionization, ionization-excitation and double ionization were determined. By applying a charged-particle imaging technique, the so-called 'reaction microscope', a large fraction of the final-state momentum space is covered, and the major limitations of previous experimental methods applied in this field could be overcome. Decisive modifications of the previous reaction microscope were undertaken, the most important one being the arrangement of the projectile beam parallel to the imaging-fields. For single ionization on helium an enhanced electron emission outside the projectile scattering plane is observed at both considered impact energies (102 eV and 1 keV), which is similar to the result found for ion-impact (M. Schulz et al., Nature (London) 422, 48 (2003)). The angle resolved cross sections obtained for double ionization at 105 eV impact energy reveal, that the process is dominated by the mutual repulsion of the three final-state continuum electrons. However, signatures of more complex dynamics are also observed. The data provide an ultimate benchmark for recently developed theories treating the dynamical three- and four-body Coulomb problem. (orig.)

  16. Electron induced break-up of helium. Benchmark experiments on a dynamical four-body Coulomb system

    Energy Technology Data Exchange (ETDEWEB)

    Duerr, M.

    2006-07-05

    This work presents an experimental study of fragmentation of helium by electron impact, in which absolute fully differential cross sections for single ionization, ionization-excitation and double ionization were determined. By applying a charged-particle imaging technique, the so-called 'reaction microscope', a large fraction of the final-state momentum space is covered, and the major limitations of previous experimental methods applied in this field could be overcome. Decisive modifications of the previous reaction microscope were undertaken, the most important one being the arrangement of the projectile beam parallel to the imaging-fields. For single ionization on helium an enhanced electron emission outside the projectile scattering plane is observed at both considered impact energies (102 eV and 1 keV), which is similar to the result found for ion-impact (M. Schulz et al., Nature (London) 422, 48 (2003)). The angle resolved cross sections obtained for double ionization at 105 eV impact energy reveal, that the process is dominated by the mutual repulsion of the three final-state continuum electrons. However, signatures of more complex dynamics are also observed. The data provide an ultimate benchmark for recently developed theories treating the dynamical three- and four-body Coulomb problem. (orig.)

  17. Nordic Walking and the Isa Method for Breast Cancer Survivors: Effects on Upper Limb Circumferences and Total Body Extracellular Water - a Pilot Study.

    Science.gov (United States)

    Di Blasio, Andrea; Morano, Teresa; Napolitano, Giorgio; Bucci, Ines; Di Santo, Serena; Gallina, Sabina; Cugusi, Lucia; Di Donato, Francesco; D'Arielli, Alberto; Cianchetti, Ettore

    2016-12-01

    The negative side effects of breast cancer treatments can include upper limb lymphoedema. The growing literature indicates that Nordic walking is an effective discipline against several disease symptoms. The aim of this study was to determine whether introduction to Nordic walking alone is effective against total body extracellular water and upper limb circumferences in breast cancer survivors compared to its combination with a series of specifically created exercises (i.e. the Isa method). 16 breast cancer survivors (49.09 ± 2.24 years) were recruited and randomly assigned to 1 of 2 different training groups. 10 lessons on Nordic walking technique plus the Isa method significantly reduced both extracellular body water and the extracellular-to-total body water ratio (p = 0.01 for both), and also the circumference of the upper limb, (both relaxed arm and forearm circumferences) (p = 0.01 for all), whereas Nordic walking alone did not. Introduction to Nordic walking does not seem to affect lymphoedema in breast cancer survivors. This might be because novice Nordic Walkers do not adequately generate an effective muscular pump through coordination of the alternated bimanual open-close cycle. The Isa method appears to close this gap.

  18. Total body irradiation and autologus bone marrow transplantation in acute leukemias and non Hodgkin-lymphomas

    Energy Technology Data Exchange (ETDEWEB)

    Corvo, R; Franzone, P; Scarpati, D; Congiu, M; Carella, A

    1986-01-01

    From january 1984 to may 1986, 31 patients, 15 ANLL, 8 ALL (in remission status) and 8 NHL (6 in remission, 2 in relapse) have been treated with chemo-radiotherapy (cyclophosphamide 60 mg/kg x 2 days + total body irradiation (TBI): 10 Gy/3 fr./3 days with 4 Gy boost testicular dose in ALL) and autologous bone marrow transplantation (BMT). Seventeen patients are alive, 16 in remission: 9 (60%) ANLL, 2 (25%) ALL, 5 (62%) NHL (median 8+ months, follow up 1+ /29+); 2 patients presented interstitial pneumonitis (6.45%). In this series, very good results have been achieved in ANLL, where no relapse was noted, encouraging achievements in NHL, with 4/8 relapse. Advantages and disadvanteges of autologus relative to allogenic BMT, and of conditioning regimen with or without TBI are discussed.

  19. Comparison of whole-body-imaging methods

    International Nuclear Information System (INIS)

    Rollo, F.D.; Hoffer, P.

    1977-01-01

    Currently there are four different devices that have found clinical utility in whole-body imaging. These are the rectilinear scanner, the multicrystal whole-body scanner, the Anger-type camera with a whole-body-imaging table, and the tomoscanner. In this text, the basic theory of operation and a discussion of the advantages and disadvantages in whole-body imaging is presented for each device. When applicable, a comparative assessment of the various devices is also presented. As with all else in life, there is no simple answer to the question ''which total body imaging device is best.'' Institutions with a very heavy total-body-imaging load may prefer to use an already available dual-headed rectilinear scanner system for these studies, rather than invest in a new instrument. Institutions with moderate total-body-imaging loads may wish to invest in moving table or moving camera devices which make total body imaging more convenient but retain the basic flexibility of the camera. The large-field Anger camera with or without motion offers another flexible option to these institutions. The laboratory with a very heavy total body imaging load may select efficiency over flexibility, thereby freeing up other instruments for additional studies. Finally, reliability as well as availability and quality of local service must be considered. After all, design features of an instrument become irrelevant when it is broken down and awaiting repair

  20. Cell biological effects of total body irradiation on growth and differentiation of acute myelogenous leukemia cells compared to normal bone marrow

    Energy Technology Data Exchange (ETDEWEB)

    Greenberger, J S; Weichselbaum, R R; Botnick, L E; Sakakeeny, M; Moloney, W C

    1979-01-01

    Radiation therapy is used as total body treatment in preparation of the acute myelogenous leukemia (AML) patient for bone marrow transplantation. Many AML patients will have residual leukemia cells at the time of total body irradiation (TBI). In the present study, the effect of TBI on leukemic myeloid cells was compared to the effect on normal marrow granulocytic stem cells (CFUc) in vitro. Little difference from that of normal CFUc was found in the radiosensitivity of two mouse myeloid leukemia cell lines. The effect of TBI on growth of WEHI-3 or J774 cells in millipore diffusion chambers was stimulatory. These AML cell lines as well as others derived from Friend or Abelson virus infected in vitro long term mouse marrow cultures showed some morphologic differentiation by 7 days growth in diffusion chambers in irradiated heterologous rat hosts, but immature cells predominated by day 21. Thus, evidence in murine models of AML indicates that residual AML cells surviving chemotherapy will show no greater susceptibility to radiation killing compared to normal stem cells and will rapidly repopulate the irradiated host.

  1. The biological effects of high dose total body irradiation in beagle dogs

    International Nuclear Information System (INIS)

    Luo Qingliang; Liu Xiaolan; Hao Jing; Xiong Guolin; Dong Bo; Zhao Zhenhu; Xia Zhengbiao; Qiu Liling; Mao Bingzhi

    2002-01-01

    Objective: To evaluate the biological effects of Beagle dogs irradiated by γ-rays at different doses. Methods: All Beagle dogs were divided into six groups and were subjected respectively to total-body irradiation (TBI) with a single dose of 6.5, 5.5, 5.0, 4.5, 3, 5 and 2.5 Gy γ-rays delivered by 60 Co sources at 7.224 x 10 -2 C/kg per minute. The general condition, blood cell counts and bone marrow cell CFC assays were observed. Results: Vomiting occurred at 0.5 to 2 hours after TBI in all groups. In 6.5 Gy group 3/5 dogs had blood-watery stool and 1/5 in 5.5 Gy group had watery stool. Diarrhea occurred in all other animals. Only one dog in 2.5 Gy group survived, all of others died. in order of decreasing irradiation dosage, the average survival time was 5.0, 8.0, 9.3, 9.5, 10.5 and 14.1 days, respectively. Conclusions: According to the clinical symptoms, leukocyte count and survival time of the dogs, the irradiation dose which will induce very severe hematopoietic radiation syndrome in Beagle dogs is 4.5 to 5.0 Gy

  2. Total Body Irradiation for Allogeneic Bone Marrow Transplantation in Chronic Myelogenous Leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Su Mi; Choi, Ihl Bohng; Kang, Ki Mun; Kim, In Ah; Shinn, Kyung Sub; Kim, Choon Choo; Kim, Dong Jip [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1994-06-15

    Between July 1987 and December 1992, we treated 22 patients with chromic myelogenous leukemia; 14 in the chronic phase and 8 with more advanced disease. All were received with allogeneic bone marrow transplantation from HLA-identical sibling donors after a total body irradiation (TBI) cyclophosphamide conditioning regimen. Patients were non-randomly assigned to either 1200 cGy/6 fractions/3 days (6 patients) or 1320 cGy/8 fractions/4 days (16 patients) by dose of TBI. Of the 22 patients, 8 were prepared with cyclophosphamide alone, 14 were conditioned with additional adriamycin or daunorubicin. To prevent graft versus host disease, cyclosporine was given either alone or in conjunction with methotrexate. The actuarial survival and leukemic-free survival at four years were 58.5% and 41.2%, respectively, and the relapse rate was 36% among 22 patients. There was a statistically significant difference in survival between the patients in chronic phase and more advanced phase (76% vs 33%, p=0.05). The relapse rate of patients receiving splenectomy was higher than that of patients receiving splenic irradiation (50% vs 0%, p=0.04). We conclude that the probability of cure is highest if transplantation is performed while the patient remains in the chronic phase.

  3. Total Body Irradiation for Allogeneic Bone Marrow Transplantation in Chronic Myelogenous Leukemia

    International Nuclear Information System (INIS)

    Chung, Su Mi; Choi, Ihl Bohng; Kang, Ki Mun; Kim, In Ah; Shinn, Kyung Sub; Kim, Choon Choo; Kim, Dong Jip

    1994-01-01

    Between July 1987 and December 1992, we treated 22 patients with chromic myelogenous leukemia; 14 in the chronic phase and 8 with more advanced disease. All were received with allogeneic bone marrow transplantation from HLA-identical sibling donors after a total body irradiation (TBI) cyclophosphamide conditioning regimen. Patients were non-randomly assigned to either 1200 cGy/6 fractions/3 days (6 patients) or 1320 cGy/8 fractions/4 days (16 patients) by dose of TBI. Of the 22 patients, 8 were prepared with cyclophosphamide alone, 14 were conditioned with additional adriamycin or daunorubicin. To prevent graft versus host disease, cyclosporine was given either alone or in conjunction with methotrexate. The actuarial survival and leukemic-free survival at four years were 58.5% and 41.2%, respectively, and the relapse rate was 36% among 22 patients. There was a statistically significant difference in survival between the patients in chronic phase and more advanced phase (76% vs 33%, p=0.05). The relapse rate of patients receiving splenectomy was higher than that of patients receiving splenic irradiation (50% vs 0%, p=0.04). We conclude that the probability of cure is highest if transplantation is performed while the patient remains in the chronic phase

  4. Understanding the many-body expansion for large systems. I. Precision considerations

    International Nuclear Information System (INIS)

    Richard, Ryan M.; Lao, Ka Un; Herbert, John M.

    2014-01-01

    Electronic structure methods based on low-order “n-body” expansions are an increasingly popular means to defeat the highly nonlinear scaling of ab initio quantum chemistry calculations, taking advantage of the inherently distributable nature of the numerous subsystem calculations. Here, we examine how the finite precision of these subsystem calculations manifests in applications to large systems, in this case, a sequence of water clusters ranging in size up to (H 2 O) 47 . Using two different computer implementations of the n-body expansion, one fully integrated into a quantum chemistry program and the other written as a separate driver routine for the same program, we examine the reproducibility of total binding energies as a function of cluster size. The combinatorial nature of the n-body expansion amplifies subtle differences between the two implementations, especially for n ⩾ 4, leading to total energies that differ by as much as several kcal/mol between two implementations of what is ostensibly the same method. This behavior can be understood based on a propagation-of-errors analysis applied to a closed-form expression for the n-body expansion, which is derived here for the first time. Discrepancies between the two implementations arise primarily from the Coulomb self-energy correction that is required when electrostatic embedding charges are implemented by means of an external driver program. For reliable results in large systems, our analysis suggests that script- or driver-based implementations should read binary output files from an electronic structure program, in full double precision, or better yet be fully integrated in a way that avoids the need to compute the aforementioned self-energy. Moreover, four-body and higher-order expansions may be too sensitive to numerical thresholds to be of practical use in large systems

  5. Discordant Documentation of Obesity Body Mass Index and Obesity Diagnosis in Electronic Medical Records

    Directory of Open Access Journals (Sweden)

    Jennifer T. Fink

    2014-11-01

    Full Text Available Purpose: This study examined concordance between presence of obesity body mass index (BMI, defined as BMI ≥ 30, in the patient’s electronic medical record (EMR and a documented diagnosis of obesity. Methods: We conducted a retrospective review of the EMR in a large health care system for a 1-year period (2012. A total of 397,313 patients met the study criteria of having at least one physician visit, being at least 18 years of age, and not being pregnant. Of those, 158,327 (40% had a recorded BMI ≥ 30. We examined the EMR of these obese patients to determine whether a diagnosis of obesity was recorded, and whether demographics or comorbid diagnoses impacted the likelihood of a recorded obesity diagnosis. Results: Obesity appeared on the EMR problem list for only 35% of patients with BMI ≥ 30. Obesity diagnosis was documented more frequently in women, middle-aged patients and blacks. The presence of some comorbidities (e.g. sleep apnea, hypertension, diabetes led to significantly more frequent diagnosis of obesity. There was a significant positive association between the number of comorbid diagnoses per patient and an obesity diagnosis appearing on the problem list. Conclusions: Obesity remains underrecorded in the EMR problem list despite the presence of obesity BMI in the EMR. Patient demographics and comorbidities should be considered when identifying best practices for weight management. New practices should be patient-centered and consider cultural context as well as the social and physical resources available to patients – all crucial for enacting systems change in a true accountable care environment.

  6. Total electron scattering cross sections of molecules containing H, C, N, O and F in the energy range 0.2–6.0 keV

    Energy Technology Data Exchange (ETDEWEB)

    Gurung, Meera Devi; Ariyasinghe, W.M., E-mail: wickram_ariyasinghe@baylor.edu

    2017-03-15

    Based on the effective atomic total electron scattering cross sections (EATCS) of atoms in a molecular environment, a simple model is proposed to predict the total electron scattering cross sections (TCS) of H, C, N, O, and F containing molecules. The EATCS for these five atoms are reported for 0.2–6.0 keV energies. The predicted TCS by this model are compared with experimental TCS in the literature. The experimental TCS of CHF{sub 3}, C{sub 2}F{sub 4}, C{sub 2}F{sub 2}H{sub 2}, C{sub 4}F{sub 6}, and c-C{sub 4}F{sub 8} have been obtained for 0.2–4.5 keV electrons by measuring the attenuation of the electron beam through a gas cell.

  7. Cherenkov imaging method for rapid optimization of clinical treatment geometry in total skin electron beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Andreozzi, Jacqueline M., E-mail: Jacqueline.M.Andreozzi.th@dartmouth.edu, E-mail: Lesley.A.Jarvis@hitchcock.org; Glaser, Adam K. [Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire 03755 (United States); Zhang, Rongxiao [Department of Physics and Astronomy, Dartmouth College, Hanover, New Hampshire 03755 (United States); Gladstone, David J.; Williams, Benjamin B.; Jarvis, Lesley A., E-mail: Jacqueline.M.Andreozzi.th@dartmouth.edu, E-mail: Lesley.A.Jarvis@hitchcock.org [Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire 03766 (United States); Pogue, Brian W. [Thayer School of Engineering and Department of Physics and Astronomy, Dartmouth College, Hanover, New Hampshire 03755 (United States)

    2016-02-15

    Purpose: A method was developed utilizing Cherenkov imaging for rapid and thorough determination of the two gantry angles that produce the most uniform treatment plane during dual-field total skin electron beam therapy (TSET). Methods: Cherenkov imaging was implemented to gather 2D measurements of relative surface dose from 6 MeV electron beams on a white polyethylene sheet. An intensified charge-coupled device camera time-gated to the Linac was used for Cherenkov emission imaging at sixty-two different gantry angles (1° increments, from 239.5° to 300.5°). Following a modified Stanford TSET technique, which uses two fields per patient position for full body coverage, composite images were created as the sum of two beam images on the sheet; each angle pair was evaluated for minimum variation across the patient region of interest. Cherenkov versus dose correlation was verified with ionization chamber measurements. The process was repeated at source to surface distance (SSD) = 441, 370.5, and 300 cm to determine optimal angle spread for varying room geometries. In addition, three patients receiving TSET using a modified Stanford six-dual field technique with 6 MeV electron beams at SSD = 441 cm were imaged during treatment. Results: As in previous studies, Cherenkov intensity was shown to directly correlate with dose for homogenous flat phantoms (R{sup 2} = 0.93), making Cherenkov imaging an appropriate candidate to assess and optimize TSET setup geometry. This method provided dense 2D images allowing 1891 possible treatment geometries to be comprehensively analyzed from one data set of 62 single images. Gantry angles historically used for TSET at their institution were 255.5° and 284.5° at SSD = 441 cm; however, the angles optimized for maximum homogeneity were found to be 252.5° and 287.5° (+6° increase in angle spread). Ionization chamber measurements confirmed improvement in dose homogeneity across the treatment field from a range of 24.4% at the initial

  8. Cytogenetic studies on recipients of allogeneic bone marrow transplants after fractionated total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, N; Goedde-Salz, E; Loeffler, H [Christian-Albrechts-Univ., Kiel (Germany, F.R.)

    1985-06-01

    Cytogenetic findings from the bone marrow (BM) and the peripheral blood (PB) of nine consecutive patients after allogeneic bone marrow transplantation (BMT) for acute or chronic myelogenous leukaemia are reported. After a conditioning regimen consisting of cyclophosphamide and fractionated total body irradiation (TBI) given in five or six fractions of 2 Gy, persistence of host cells was detected in four out of seven cases with permanent engraftment. While one of these patients relapsed 4 months after host cells had been found in BM and PB, the other patients stayed relapse-free 124, 257 and 347 d after grafting. Before transplantation, the leukaemic cells in all three cases carried unique cytogenetic abnormalities giving the opportunity to distinguish the leukaemic population from chromosomally non-aberrant cells thought to represent residual normal host cells. As the persisting host cells after BMT lacked any cytogenetic abnormalities, it is suggested that they were members of residual normal clones not involved in the leukaemic process.

  9. Time- and dose-dependent effects of total-body ionizing radiation on muscle stem cells

    Science.gov (United States)

    Masuda, Shinya; Hisamatsu, Tsubasa; Seko, Daiki; Urata, Yoshishige; Goto, Shinji; Li, Tao-Sheng; Ono, Yusuke

    2015-01-01

    Exposure to high levels of genotoxic stress, such as high-dose ionizing radiation, increases both cancer and noncancer risks. However, it remains debatable whether low-dose ionizing radiation reduces cellular function, or rather induces hormetic health benefits. Here, we investigated the effects of total-body γ-ray radiation on muscle stem cells, called satellite cells. Adult C57BL/6 mice were exposed to γ-radiation at low- to high-dose rates (low, 2 or 10 mGy/day; moderate, 50 mGy/day; high, 250 mGy/day) for 30 days. No hormetic responses in proliferation, differentiation, or self-renewal of satellite cells were observed in low-dose radiation-exposed mice at the acute phase. However, at the chronic phase, population expansion of satellite cell-derived progeny was slightly decreased in mice exposed to low-dose radiation. Taken together, low-dose ionizing irradiation may suppress satellite cell function, rather than induce hormetic health benefits, in skeletal muscle in adult mice. PMID:25869487

  10. Anti-tumor effect of total body irradiation of low doses on WHT/Ht mice

    International Nuclear Information System (INIS)

    Miyamoto, Miyako; Sakamoto, Kiyohiko

    1987-01-01

    The effect of low dose (0.05 - 1.0 Gy) of total body irradiation (TBI) on non-tumor bearing and tumor bearing mice were investigated. Mice received TBI of 0.1 Gy during 6 - 12 hours before tumor cell inoculation demonstrated to need larger number of tumor cells (approximately 2.5 times) for 50 per cent tumor incidence, compared to recipient mice not to receive TBI. On the other hand, in tumor bearing mice given 0.1 Gy of TBI only tumor cell killing effect was not detected, however enhancement of tumor cell killing effect and prolonged growth delay were observed when tumor bearing mice were treated with 0.1 Gy of TBI in combined with local irradiation on tumors, especially cell killing effect was remarkable in dose range over 6 Gy of local exposure. The mechanism of the effect of 0.1 Gy TBI is considered to be host mediated reactions from the other our experimental results. (author)

  11. Cytogenetic studies on recipients of allogeneic bone marrow transplants after fractionated total body irradiation

    International Nuclear Information System (INIS)

    Schmitz, N.; Goedde-Salz, E.; Loeffler, H.

    1985-01-01

    Cytogenetic findings from the bone marrow (BM) and the peripheral blood (PB) of nine consecutive patients after allogeneic bone marrow transplantation (BMT) for acute or chronic myelogenous leukaemia are reported. After a conditioning regimen consisting of cyclophosphamide and fractionated total body irradiation (TBI) given in five or six fractions of 2 Gy, persistence of host cells was detected in four out of seven cases with permanent engraftment. While one of these patients relapsed 4 months after host cells had been found in BM and PB, the other patients stayed relapse-free 124, 257 and 347 d after grafting. Before transplantation, the leukaemic cells in all three cases carried unique cytogenetic abnormalities giving the opportunity to distinguish the leukaemic population from chromosomally non-aberrant cells thought to represent residual normal host cells. As the persisting host cells after BMT lacked any cytogenetic abnormalities, it is suggested that they were members of residual normal clones not involved in the leukaemic process. (author)

  12. In vivo dosimetry with semiconducting diodes for dose verification in total-body irradiation. A 10-year experience

    International Nuclear Information System (INIS)

    Ramm, U.; Licher, J.; Moog, J.; Scherf, C.; Kara, E.; Boettcher, H.D.; Roedel, C.; Mose, S.

    2008-01-01

    Background and purpose: for total-body irradiation (TBI) using the translation method, dose distribution cannot be computed with computer-assisted three-dimensional planning systems. Therefore, dose distribution has to be primarily estimated based on CT scans (beam-zone method) which is followed by in vivo measurements to ascertain a homogeneous dose delivery. The aim of this study was to clinically establish semiconductor probes as a simple and fast method to obtain an online verification of the dose at relevant points. Patients and methods: in 110 consecutively irradiated TBI patients (12.6 Gy, 2 x 1.8 Gy/day), six semiconductor probes were attached to the body surface at dose-relevant points (eye/head, neck, lung, navel). The mid-body point of the abdomen was defined as dose reference point. The speed of translation was optimized to definitively reach the prescribed dose in this point. Based on the entrance and exit doses, the mid-body doses at the other points were computed. The dose homogeneity in the entire target volume was determined comparing all measured data with the dose at the reference point. Results: after calibration of the semiconductor probes under treatment conditions the dose in selected points and the dose homogeneity in the target volume could be quantitatively specified. In the TBI patients, conformity of calculated and measured doses in the given points was achieved with small deviations of adequate accuracy. The data of 80% of the patients are within an uncertainty of ± 5%. Conclusion: during TBI using the translation method, dose distribution and dose homogeneity can be easily controlled in selected points by means of semiconductor probes. Semiconductor probes are recommended for further use in the physical evaluation of TBI. (orig.)

  13. A Giant Hepatic Hemangioma Complicated by Kasabach-Merritt Syndrome: Findings of Tc-99m RBC Scintigraphy and SPECT Including a Total Body Blood Pool Imaging Study

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Myung Hee; Jeong, Hwan Jeong; Lim, Seok Tae; Kim, Dong Wook; Yim, Chang Yeol [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2009-02-15

    Kasabach-Merritt syndrome (KMS) consists of thrombocytopenia, microangiopathic hemolytic anemia, and localized consumption coagulopathy that develops within vascular hemangioma. This syndrome may also be associated with occult hemangiomas located at various sites. Tc-99m RBC scintigraphy and SPECT have proven to be reliable for confirming or excluding hemangioma. Total body blood pool imaging study during the scintigraphy also provides a means of screening for occult lesions. The authors report the case of a 29-year-old man who presented with a giant hepatic hemangioma complicated by KMS, and underwent Tc-99m RBC scintigraphy and SPECT including a total body blood pool imaging study.

  14. Design and characteristics of a 4 MV total body irradiator

    International Nuclear Information System (INIS)

    Lutz, W.R.; Chin, L.M.

    1988-01-01

    A facility for total body X-ray irradiation (TBI) has been built using two 4 MV linear accelerators, one mounted under the ceiling, the other in a floor-pit. The distance between the two sources is 410 cm to produce a field size of 200 cm x 75 cm in the midplane. This field covers the patient, lying supine on a stretcher halfway between the sources. Components from commercially available accelerators were used. Special beam hardening and flattening filters were built to achieve acceptable dose profiles in the large field. The primary collimator was modified to produce a 235 cm x 92 cm field at 205 cm from the source, while movable focused collimators were designed to define fields up to 220 cm x 80 cm. Because of the wide beams, large rectangular parallel-plate ionization chambers were built to serve as beam monitors. The dose rate at 205 cm distance from the sources can be set between 5 and 80 cGy/min, each machine contributing half. The dosimetric characteristics are practically the same for both units. The per cent depth dose for the TBI beams is 76% at a source-surface distance of 195 cm. The half value layer decreases by 12% from the centre to near the edge of the beam. Owing to the large field size, the surface dose for the TBI beams is about 80% of the dose at 1 cm depth. The dose delivery has been verified to be within 2% of the calculated value at the reference point in a homogeneous water humanoid phantom. Measurements indicate that lung doses can be predicted by the ratio-of-TMR (tissue-to-maximum ratio) method with acceptable accuracy. Lead sheets are used as attenuators to prevent excessive lung doses. (author). 7 refs, 7 figs

  15. Compendium of Current Total Ionizing Dose and Displacement Damage Results from NASA Goddard Space Flight Center and NASA Electronic Parts and Packaging Program

    Science.gov (United States)

    Topper, Alyson D.; Campola, Michael J.; Chen, Dakai; Casey, Megan C.; Yau, Ka-Yen; Cochran, Donna J.; Label, Kenneth A.; Ladbury, Raymond L.; Mondy, Timothy K.; O'Bryan, Martha V.; hide

    2017-01-01

    Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices. Displacement Damage, Optoelectronics, Proton Damage, Single Event Effects, and Total Ionizing Dose.

  16. Insulin-Like Growth Factor 1 Mitigates Hematopoietic Toxicity After Lethal Total Body Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Dunhua; Deoliveira, Divino; Kang, Yubin; Choi, Seung S. [Department of Medicine, Duke University Medical Center, Durham, North Carolina (United States); Li, Zhiguo [Department of Biostatistics and Bioinformatics, Duke University Medical Center, Durham, North Carolina (United States); Chao, Nelson J. [Department of Medicine, Duke University Medical Center, Durham, North Carolina (United States); Department of Pathology, Duke University Medical Center, Durham, North Carolina (United States); Department of Immunology, Duke University Medical Center, Durham, North Carolina (United States); Duke Cancer Institute, Duke University Medical Center, Durham, North Carolina (United States); Chen, Benny J., E-mail: chen0032@mc.duke.edu [Duke Cancer Institute, Duke University Medical Center, Durham, North Carolina (United States); Department of Medicine, Duke University Medical Center, Durham, North Carolina (United States)

    2013-03-15

    Purpose: To investigate whether and how insulin-like growth factor 1 (IGF-1) mitigates hematopoietic toxicity after total body irradiation. Methods and Materials: BALB/c mice were irradiated with a lethal dose of radiation (7.5 Gy) and treated with IGF-1 at a dose of 100 μg/dose intravenously once a day for 5 consecutive days starting within 1 hour after exposure. Survival and hematopoietic recovery were monitored. The mechanisms by which IGF-1 promotes hematopoietic recovery were also studied by use of an in vitro culture system. Results: IGF-1 protected 8 of 20 mice (40%) from lethal irradiation, whereas only 2 of 20 mice (10%) in the saline control group survived for more than 100 days after irradiation. A single dose of IGF-1 (500 μg) was as effective as daily dosing for 5 days. Positive effects were noted even when the initiation of treatment was delayed as long as 6 hours after irradiation. In comparison with the saline control group, treatment with IGF-1 significantly accelerated the recovery of both platelets and red blood cells in peripheral blood, total cell numbers, hematopoietic stem cells, and progenitor cells in the bone marrow when measured at day 14 after irradiation. IGF-1 protected both hematopoietic stem cells and progenitor cells from radiation-induced apoptosis and cell death. In addition, IGF-1 was able to facilitate the proliferation and differentiation of nonirradiated and irradiated hematopoietic progenitor cells. Conclusions: IGF-1 mitigates radiation-induced hematopoietic toxicity through protecting hematopoietic stem cells and progenitor cells from apoptosis and enhancing proliferation and differentiation of the surviving hematopoietic progenitor cells.

  17. Insulin-Like Growth Factor 1 Mitigates Hematopoietic Toxicity After Lethal Total Body Irradiation

    International Nuclear Information System (INIS)

    Zhou, Dunhua; Deoliveira, Divino; Kang, Yubin; Choi, Seung S.; Li, Zhiguo; Chao, Nelson J.; Chen, Benny J.

    2013-01-01

    Purpose: To investigate whether and how insulin-like growth factor 1 (IGF-1) mitigates hematopoietic toxicity after total body irradiation. Methods and Materials: BALB/c mice were irradiated with a lethal dose of radiation (7.5 Gy) and treated with IGF-1 at a dose of 100 μg/dose intravenously once a day for 5 consecutive days starting within 1 hour after exposure. Survival and hematopoietic recovery were monitored. The mechanisms by which IGF-1 promotes hematopoietic recovery were also studied by use of an in vitro culture system. Results: IGF-1 protected 8 of 20 mice (40%) from lethal irradiation, whereas only 2 of 20 mice (10%) in the saline control group survived for more than 100 days after irradiation. A single dose of IGF-1 (500 μg) was as effective as daily dosing for 5 days. Positive effects were noted even when the initiation of treatment was delayed as long as 6 hours after irradiation. In comparison with the saline control group, treatment with IGF-1 significantly accelerated the recovery of both platelets and red blood cells in peripheral blood, total cell numbers, hematopoietic stem cells, and progenitor cells in the bone marrow when measured at day 14 after irradiation. IGF-1 protected both hematopoietic stem cells and progenitor cells from radiation-induced apoptosis and cell death. In addition, IGF-1 was able to facilitate the proliferation and differentiation of nonirradiated and irradiated hematopoietic progenitor cells. Conclusions: IGF-1 mitigates radiation-induced hematopoietic toxicity through protecting hematopoietic stem cells and progenitor cells from apoptosis and enhancing proliferation and differentiation of the surviving hematopoietic progenitor cells

  18. Improved models for determination of body fat by in vivo neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.; Vaswani, A.; Yasumura, S.; Yuen, K.; Ellis, K.

    1984-01-01

    In the present study, two different models of body composition, based on data obtained by nuclear techniques are used. Total body nitrogen, calcium, and chlorine were obtained by total body neutron activation. Total body chlorine was used to estimate extracellular water, and total body calcium to determine bone mineral and extracellular solids. Total body potassium was measured by whole body counting to obtain the body cell mass. In addition, total body water was measured by the tritium dilution technique. It was found that either model can be used equally well to measure total body fat in normal subjects. Estimation of body fat as the difference between body weight and the sum of total body nitrogen (protein), total body water, and bone ash (model 1) appears to have an advantage over model 2, which uses body cell mass, extracellular water, and extracellular solids, particularly for patients with metabolic disorders. This advantage is partly due to the fact that the parameter protein (total body nitrogen) is less affected in metabolic disorders than the more labile total body potassium. The closely correlated results obtained with the two models based on nuclear measurements support the conclusion that these techniques provide reliable measurements of total body fat

  19. On forecasting ionospheric total electron content responses to high-speed solar wind streams

    Directory of Open Access Journals (Sweden)

    Meng Xing

    2016-01-01

    Full Text Available Conditions in the ionosphere have become increasingly important to forecast, since more and more spaceborne and ground-based technological systems rely on ionospheric weather. Here we explore the feasibility of ionospheric forecasts with the current generation of physics-based models. In particular, we focus on total electron content (TEC predictions using the Global Ionosphere-Thermosphere Model (GITM. Simulations are configured in a forecast mode and performed for four typical high-speed-stream events during 2007–2012. The simulated TECs are quantified through a metric, which divides the globe into a number of local regions and robustly differentiates between quiet and disturbed periods. Proposed forecast products are hourly global maps color-coded by the TEC disturbance level of each local region. To assess the forecasts, we compare the simulated TEC disturbances with global TEC maps derived from Global Positioning System (GPS satellite observations. The forecast performance is found to be merely acceptable, with a large number of regions where the observed variations are not captured by the simulations. Examples of model-data agreements and disagreements are investigated in detail, aiming to understand the model behavior and improve future forecasts. For one event, we identify two adjacent regions with similar TEC observations but significant differences in how local chemistry versus plasma transport contribute to electron density changes in the simulation. Suggestions for further analysis are described.

  20. CT analysis of lung density changes in patients undergoing total body irradiation prior to bone marrow transplantation

    International Nuclear Information System (INIS)

    Lee, J.Y.; Shank, B.; Bonfiglio, P.; Reid, A.

    1984-01-01

    Sequential changes in lung density measured by CT are potentially sensitive and convenient monitors of lung abnormalities following total body irradiation (TBI). Methods have been developed to compare pre- and post-TBI CT of lung. The average local features of a cross-sectional lung slice are extracted from three peripheral regions of interest in the anterior, posterior, and lateral portions of the CT image. Also, density profiles across a specific region may be obtained. These may be compared first for verification of patient position and breathing status and then for changes between pre- and post-TBI. These may also be compared with radiation dose profiles through the lung. A preliminary study on 21 leukemia patients undergoing total body irradiation indicates the following: (a) Density gradients of patients' lungs in the antero-posterior direction show a marked heterogeneity before and after transplantation compared with normal lungs. The patients with departures from normal density gradients pre-TBI correlate with later pulmonary complications. (b) Measurements of average peripheral lung densities have demonstrated that the average lung density in the younger age group is substantially higher: pre-TBI, the average CT number (1,000 scale) is -638 +/- 39 Hounsfield unit (HU) for 0-10 years old and -739 +/- 53 HU for 21-40 years old. (c) Density profiles showed no post-TBI regional changes in lung density corresponding to the dose profile across the lung, so no differentiation of a radiation-specific effect has yet been possible. Computed tomographic density profiles in the antero-posterior direction are successfully used to verify positioning of the CT slice and the breathing level of the lung

  1. Dose enhancement in the neighborhood of foreign bodies of the skin due to electron irradiation. A Monte-Carlo study using MCNP

    Energy Technology Data Exchange (ETDEWEB)

    Heide, Bernd [Karlsruhe Institute of Technology (KIT), Eggenstein-Leopoldshafen (DE). Inst. of Radiation Research (ISF)

    2011-07-01

    Foreign bodies penetrate into the skin in the region of the hand very frequently. If they are amicrobic, they can get stuck in the skin and do no harm to the body in normal case. However, when handling with a radioactive material, like an Sr-90/Y-90 syringe for example, a stuck foreign body in a finger can lead to an enhanced absorbed dose in the neighbourhood of a few hundredths of millimetre of a foreign body, which just is in magnitude of a body cell. In the following, we shall investigate the dose enhancement effect of graphite, lead, and gold when embedded in soft tissue and irradiated with electrons. This case study focusses on the region close to the piece of metal (foreign body) without consideration for the depth in which the foreign body is located. It holds some other idealised assumptions (concerning vacuum, shape and size of foreign bodies, tissue composition, and direction of the radiation field) but still is near to real situations. Among others, this case study served to estimate the dose enhancement in the neighbourhood of a pike of lead located at the right forefinger of a member of our Institute of Radiation Research after an Sr-90/Y-90 irradiation. (orig.)

  2. Spatial relationship of 1-meter equatorial spread-F irregularities and depletions in total electron content

    International Nuclear Information System (INIS)

    Tsunoda, R.T.; Towle, D.M.

    1979-01-01

    An experiment was conducted at Kwajalein Atoll, Marshall Islands to investigate the spatial relationship of 1-m equatorial spread-F irregularities to total electron content (TEC) depletions. A high-power radar was operated (1) in a backscatter scan mode to spatially map the distribution of 1-m irregularities, and (2) in a dual-frequency, satellite-track mode to obtain the longitudinal TEC variations. We show that radar backscatter ''plumes'' found in the disturbed, nighttime equatorial ionosphere are longitudinally coincident with TEC depletions. We suggest that the TEC depletions are probably due to the presence of plasma ''bubbles'' in the equatorial F layer

  3. Validation and dosimetric evaluation employing the techniques of TL and OSL of thermoluminescent materials for application in the dosimetry of clinical beams of electrons used in total irradiation of the skin - TSI

    International Nuclear Information System (INIS)

    Almeida, Shirlane Barbosa de

    2017-01-01

    In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. TSI dosimetry is difficult because of the complexity of the treatment in assessing dose uniformity and measuring the dose absorbed at shallow depths throughout the skin surface extent, resulting in a wide variation in dose distribution. The TLDs have proven to be very useful for the distribution and verification of the dose prescribed for the patient as the dose may differ from place to place due to patient body geometry, overlapping of structures and asymmetries of the radiation field. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. Several types of dosimeters have been used in the radiotherapy sectors, the most commonly used are Lithium Fluride (TLD-100), where it obtains a long history in this type of application. New dosimetric materials have gained great importance in the dosimetry of clinical electron beams, such as Dysprosium-doped Calcium Sulphate (TL) and Carbon doped (OSL) based Aluminum Oxide, This work evaluates the performance of the respective thermoluminescent dosimeters and the optically stimulated luminescence in the dosimetry of clinical electron beams used in total irradiation of the skin. (author)

  4. SU-E-T-515: Field-In-Field Compensation Technique Using Multi-Leaf Collimator to Deliver Total Body Irradiation (TBI) Dose

    Energy Technology Data Exchange (ETDEWEB)

    Lakeman, T [The State University of New York at Buffalo (United States); Wang, IZ [The State University of New York at Buffalo (United States); Roswell Park Cancer Institute, Buffalo, NY (United States)

    2014-06-01

    Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient's immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has been used conventionally to compensate for the varying thickness through the entire body in large-field TBI. The goal of this study is to pursue utilizing the modern field-in-field (FIF) technique with the multi-leaf collimator (MLC) to more accurately and efficiently deliver dose to patients in need of TBI. Method: Treatment plans utilizing the FIF technique to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Treatment fields include one pair of opposed open large fields (collimator=45°) with a specific weighting and a succession of smaller fields (collimator=90°) each with their own weighting. The smaller fields are shaped by moving MLC to block the sections of the patient which have already received close to 100% of the prescribed dose. The weighting factors for each of these fields were calculated using the attenuation coefficient of the initial lead compensators and the separation of the patient in different positions in the axial plane. Results: Dose-volume histograms (DVH) were calculated for evaluating the FIF compensation technique. The maximum body doses calculated from the DVH were reduced from the non-compensated 179.3% to 148.2% in the FIF plans, indicating a more uniform dose with the FIF compensation. All calculated monitor units were well within clinically acceptable limits and exceeded those of the original lead compensation plan by less than 50 MU (only ~1.1% increase). Conclusion: MLC FIF technique for TBI will not significantly increase the beam on time while it can substantially reduce the compensator setup time and the potential risk of errors in manually placing lead compensators.

  5. An experimental model of acute encephalopathy after total body irradiation in the rat: effect of liposome-entrapped Cu/Zn superoxide dismutase

    International Nuclear Information System (INIS)

    Lamproglou, Ioannis; Magdelenat, Henri; Boisserie, Gilbert; Baillet, Francois; Mayo, Willy; Fessi, Hatem; Puisieux, Francis; Perderau, Bernard; Colas-Linhart, Nicole; Delattre, Jean-Yves

    1998-01-01

    Purpose: To develop an experimental model of acute encephalopathy following total body irradiation in rats and to define the therapeutic effect of liposome-entrapped Cu/Zn superoxide dismutase. Methods and Materials: A total of 120 4-month-old rats received 4.5 Gy total body irradiation (TBI) while 120 rats received sham irradiation. A behavioral study based on a conditioning test of negative reinforcement, the one-way avoidance test, was performed 5 hours before irradiation and repeated the following days. Subcutaneous treatment was started 1 hour after irradiation and repeated daily for 2 weeks. In both the irradiated and sham group, three subgroups were defined according to the treatment received: liposome-entrapped Cu/Zn superoxide dismutase (0.5 mg/kg), liposomes only, normal saline. Results: This work comprised two consecutive studies. In study A (90 rats) the one-way avoidance test was administered daily from day 0 to day 4 with a recall session at day 14. In study B (validation phase in 150 rats) the behavioral test was performed only from day 0 to day 6. Before irradiation, all rats showed a similar behavioral response. Study A (6 groups of 15 rats): Following TBI, irradiated rats treated with liposomes only or saline demonstrated a significant delay in learning the one-way avoidance test in comparison with sham-irradiated rats (0.05 < p <0.001 depending upon the day of evaluation and the subgroup type). In contrast, irradiated rats treated with liposome-entrapped Cu/Zn superoxide dismutase did not differ from sham-irradiated rats. Study B (6 groups of 25 rats): The results were the same as those in study A, demonstrating a significant delay in the learning of the test in the liposome and saline-treated irradiated rats in comparison with sham-irradiated rats (0.02 < p < 0.001). The irradiated rats, treated with liposome-entrapped Cu/Zn superoxide dismutase did not differ from the sham-irradiated controls. Conclusion: This study indicates that a relatively

  6. Fiber-coupled Al2O3:C radioluminescence dosimetry for total body irradiations

    DEFF Research Database (Denmark)

    Buranurak, Siritorn; Andersen, Claus E.

    2016-01-01

    in the context of Total Body Irradiations (TBIs) where patients are treated with large fields of 6 or 18 MV photons at an extended source-to-surface distance (SSD). The study shows that Al2O3:C dosimetry using the saturated-RL protocol may be suitable for real-time in vivo dosimetry during TBI treatments from...... the perspective of the good agreement with alanine dosimetry and other critical phantom tests, including the ability to cope with the large stem signal experienced during TBI treatments at extended SSD. In contrast, the chromatic stem removal technique often used for organic plastic scintillators did not work...

  7. Linear electron accelerator body and method of its manufacture

    International Nuclear Information System (INIS)

    Landa, V.; Maresova, V.; Lucek, J.; Prusa, F.

    1988-01-01

    The accelerator body consists of a hollow casing made of a high electric conductivity metal. The inside is partitioned with a system of resonators. The resonator body is made of one piece of the same metal as the casing or a related one (e.g., copper -coper, silver-copper, copper-copper alloy). The accelerator body is manufactured using the cathodic process on the periphery of a system of metal partitions and negative models of resonator cavities fitted to a metal pin. The pin is then removed from the system and the soluble models of the cavities are dissolved in a solvent. The advantage of the design and the method of manufacture is that the result is a compact, perfectly tight body with a perfectly lustre surface. The casing wall can be very thin, which improves accelerator performance. The claimed method can also be used in manufacturing miniature accelerators. (E.J.). 1 fig

  8. The structure of the latidudinal total electron content (T.E.C.). Gradients over mid-latitude stations

    International Nuclear Information System (INIS)

    Keroub, I.H.

    1976-01-01

    New results concerning the day gradients of Total Electron Contents (T.E.C.) in Haifa region were obtained by the method specific for the determination of TEC in the transverse zone. The latitudinal gradients thus obtained agree with the results obtained by topside sounding (Alouette 1 satellite). A quantitative explanation of the results yielded by the classical counting method is presented. Il implies that all day TEC data obtained by the counting methods in stations situated at middle geomagnetic latitudes such as Haifa, must be corrected

  9. Long-term results of total body irradiation in adults with acute lymphoblastic leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Marnitz, Simone; Zich, Alexander; Budach, Volker; Jahn, Ulrich; Neumann, Oliver [Charite University Medicine, Department of Radiation Oncology, Berlin (Germany); Martus, Peter [University Tuebingen, Institute of Clinical Epidemiology and Applied Biostatistics, Tuebingen (Germany); Arnold, Renate [Charite University Medicine, Campus CVK, Department of Hematology and Oncology, Bone Marrow Transplant Unit, Berlin (Germany)

    2014-05-15

    The aim of this chart review of adult patients treated for acute lymphoblastic leukemia (ALL) with total body irradiation (TBI) was to evaluate early and late toxicity and long-term outcome. A total of 110 adult patients (34 ± 12 years) with ALL underwent TBI (6 fractions of 2 Gy for a total of 12 Gy) as a part of the treatment regimen before transplantation. Treatment-related toxicity, mortality, and hematologic outcome are reported. Mean follow-up was 70 months. The 2- and 5-year leukemia-free survival rates were 78 and 72 %, respectively. In all, 29 % (32/110) patients suffered from medullary recurrence after a median time of 7 months. Gender was the only statistically significant prognostic factor in terms of overall survival in favor of female patients. Treatment-related mortality and overall survival after 2 and 5 years were 16 and 22 %, and 60 and 52.7 %, respectively. The most frequent late reaction wascGVHD of the skin (n = 33, 30 %). In addition, 15.5 % (17/110 patients) suffered pulmonary symptoms, and 6 patients developed lung fibrosis. Eyes were frequently affected by the radiation (31/110 = 28 %); 12 of 110 patients (11 %) presented with symptoms from osteoporosis, 5 of 110 patients (4.5 %) developed hypothyreosis and 2 patients diabetes mellitus. Of the male patients, 11 % reported erectile dysfunction or loss of libido, while 2 of 36 women reported menopausal syndrome at the mean time of 28 months after treatment with requirement for substitution. No women became pregnant after treatment. No acute or late cardiac toxicities were documented in our patients. No secondary malignancies were documented. Although hematologic outcome was in the upper range of that reported in the literature, treatment-related mortality (TRM) and medullary recurrences remain a challenge. Sophisticated radiation techniques allow for decreasing toxicity to certain organs and/or dose escalation to the bone marrow in highly selected patients in order to improve therapeutic

  10. The association between body mass index and duration spent on electronic devices in children and adolescents in Western Saudi Arabia.

    Science.gov (United States)

    Al-Agha, Abdulmoein E; Nizar, F Sarah; Nahhas, Anwar M

    2016-04-01

    To evaluate the relationship between body mass index (BMI) and the duration spent on electronic devices, and to assess the factors that can cause obesity among children. A cross-sectional study including 541 participants. Data was collected from March to June 2015 via ambulatory pediatric clinics in Jeddah, Kingdom of Saudi Arabia. The BMI standard deviation was calculated based on Center of Disease Control and Prevention (CDC) standards. The mean age of the participants was 10.1 years. Children who spent ≥2 hours daily on electronic devices showed an increased BMI, and made up 68.4% of the sample. An increased BMI was more common among children who spent ≥2 hours daily on electronic devices. The relationship between BMI, reduced physical activity, and eating during television viewing was determined.

  11. Monitoring total-body inflammation and damage in joints and entheses

    DEFF Research Database (Denmark)

    Axelsen, M. B.; Eshed, I.; Østergaard, M.

    2017-01-01

    Objective: To investigate changes in whole-body magnetic resonance imaging (WBMRI) inflammatory and structural lesions in most joints and entheses in patients with rheumatoid arthritis (RA) treated with adalimumab. Methods: WBMRI was obtained at weeks 0, 6, 16, and 52 in a 52 week follow-up study...

  12. Perceptual and Brain Response to Odors Is Associated with Body Mass Index and Postprandial Total Ghrelin Reactivity to a Meal.

    Science.gov (United States)

    Sun, Xue; Veldhuizen, Maria G; Babbs, Amanda E; Sinha, Rajita; Small, Dana M

    2016-03-01

    Animal studies have shown that olfactory sensitivity is greater when fasted than when fed. However, human research has generated inconsistent results. One possible explanation for these conflicting findings is metabolic health. Many metabolic peptides, including ghrelin, are moderated by adiposity and influence olfaction and olfactory-guided behaviors. We tested whether the effect of a meal on the perceived intensity of suprathreshold chemosensory stimuli is influenced by body mass index and/or metabolic response to a meal. We found that overweight or obese (n = 13), but not healthy weight (n = 20) subjects perceived odors, but not flavored solutions, as more intense when hungry than when sated. This effect was correlated with reduced postprandial total ghrelin suppression (n = 23) and differential brain response to odors in the cerebellum, as measured with functional magnetic resonance imaging. In contrast, it was unrelated to circulating leptin, glucose, insulin, triglycerides, or free fatty acids; or to odor pleasantness or sniffing (n = 24). These findings demonstrate that the effect of a meal on suprathreshold odor intensity perception is associated with metabolic measures such as body weight and total ghrelin reactivity, supporting endocrine influences on olfactory perception. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. Electron paramagnetic resonance image reconstruction with total variation and curvelets regularization

    Science.gov (United States)

    Durand, Sylvain; Frapart, Yves-Michel; Kerebel, Maud

    2017-11-01

    Spatial electron paramagnetic resonance imaging (EPRI) is a recent method to localize and characterize free radicals in vivo or in vitro, leading to applications in material and biomedical sciences. To improve the quality of the reconstruction obtained by EPRI, a variational method is proposed to inverse the image formation model. It is based on a least-square data-fidelity term and the total variation and Besov seminorm for the regularization term. To fully comprehend the Besov seminorm, an implementation using the curvelet transform and the L 1 norm enforcing the sparsity is proposed. It allows our model to reconstruct both image where acquisition information are missing and image with details in textured areas, thus opening possibilities to reduce acquisition times. To implement the minimization problem using the algorithm developed by Chambolle and Pock, a thorough analysis of the direct model is undertaken and the latter is inverted while avoiding the use of filtered backprojection (FBP) and of non-uniform Fourier transform. Numerical experiments are carried out on simulated data, where the proposed model outperforms both visually and quantitatively the classical model using deconvolution and FBP. Improved reconstructions on real data, acquired on an irradiated distal phalanx, were successfully obtained.

  14. On the use of unshielded cables in ionization chamber dosimetry for total-skin electron therapy

    International Nuclear Information System (INIS)

    Zhe Chen; Agostinelli, Alfred; Nath, Ravinder

    1998-01-01

    The dosimetry of total-skin electron therapy (TSET) usually requires ionization chamber measurements in a large electron beam (up to 120cmx200cm). Exposing the chamber's electric cable, its connector and part of the extension cable to the large electron beam will introduce unwanted electronic signals that may lead to inaccurate dosimetry results. While the best strategy to minimize the cable-induced electronic signal is to shield the cables and its connector from the primary electrons, as has been recommended by the AAPM Task Group Report 23 on TSET, cables without additional shielding are often used in TSET dosimetry measurements for logistic reasons, for example when an automatic scanning dosimetry is used. This paper systematically investigates the consequences and the acceptability of using an unshielded cable in ionization chamber dosimetry in a large TSET electron beam. In this paper, we separate cable-induced signals into two types. The type-I signal includes all charges induced which do not change sign upon switching the chamber polarity, and type II includes all those that do. The type-I signal is easily cancelled by the polarity averaging method. The type-II cable-induced signal is independent of the depth of the chamber in a phantom and its magnitude relative to the true signal determines the acceptability of a cable for use under unshielded conditions. Three different cables were evaluated in two different TSET beams in this investigation. For dosimetry near the depth of maximum buildup, the cable-induced dosimetry error was found to be less than 0.2% when the two-polarity averaging technique was applied. At greater depths, the relative dosimetry error was found to increase at a rate approximately equal to the inverse of the electron depth dose. Since the application of the two-polarity averaging technique requires a constant-irradiation condition, it was demonstrated that an additional error of up to 4% could be introduced if the unshielded cable

  15. Evaluation of extreme ionospheric total electron content gradient associated with plasma bubbles for GNSS Ground-Based Augmentation System

    Science.gov (United States)

    Saito, S.; Yoshihara, T.

    2017-08-01

    Associated with plasma bubbles, extreme spatial gradients in ionospheric total electron content (TEC) were observed on 8 April 2008 at Ishigaki (24.3°N, 124.2°E, +19.6° magnetic latitude), Japan. The largest gradient was 3.38 TECU km-1 (total electron content unit, 1 TECU = 1016 el m-2), which is equivalent to an ionospheric delay gradient of 540 mm km-1 at the GPS L1 frequency (1.57542 GHz). This value is confirmed by using multiple estimating methods. The observed value exceeds the maximum ionospheric gradient that has ever been observed (412 mm km-1 or 2.59 TECU km-1) to be associated with a severe magnetic storm. It also exceeds the assumed maximum value (500 mm km-1 or 3.08 TECU km-1) which was used to validate the draft international standard for Global Navigation Satellite System (GNSS) Ground-Based Augmentation Systems (GBAS) to support Category II/III approaches and landings. The steepest part of this extreme gradient had a scale size of 5.3 km, and the front-normal velocities were estimated to be 71 m s-1 with a wavefront-normal direction of east-northeastward. The total width of the transition region from outside to inside the plasma bubble was estimated to be 35.3 km. The gradient of relatively small spatial scale size may fall between an aircraft and a GBAS ground subsystem and may be undetectable by both aircraft and ground.

  16. Electronic and optical properties of phosphorene-like arsenic phosphorus: a many-body study

    Science.gov (United States)

    Shu, Huabing; Guo, Jiyuan

    2018-03-01

    By employing density functional and many-body perturbation theories, we explore the geometrics, quasiparticle band structure, and optical response of two-dimensional arsenic phosphorus (α-AsxP1-x). Calculations indicate that the α-AsxP1-x exhibits excellent stability at high temperature. The quasi-particle bandgap of α-AsxP1-x is highly tunable in a broad range of 1.54-2.14 eV depending on the composition. The optical absorption of α-AsxP1-x can cover the visible and ultraviolet regions, and is highly anisotropic. More interestingly, it is tunable to optical absorption of α-AsxP1-x when the composition continuously increased. Also, they have sizable exciton binding energies. These findings suggest that α-AsxP1-x holds great potentials for applications in high-performance electronics and optoelectronics.

  17. Vesicovaginal fistula, bladder calculus, retained foreign body or all of the above? The unusual presentation of a female with total urinary incontinence

    Directory of Open Access Journals (Sweden)

    L. Paik

    2014-06-01

    Full Text Available A 78-year-old female with total urinary incontinence was referred to Tygerberg Hospital. On physical exam a firm mass consistent with a stone was palpated along the anterior vagina and confirmed with KUB X-ray and ultrasonography. Under general anesthesia cystolithalopaxy was performed and the vaginal component was removed manually. A foreign body (aerosol cap was identified in the vagina as the underlying cause. The aerosol cap had eroded through the anterior vaginal wall resulting in a vesicovaginal fistula. A biopsy of the fistulous tract demonstrated granulation tissue with no evidence of malignancy. A discussion of retained foreign bodies causing vesicovaginal fistula, specifically aerosol bottle caps, follows.

  18. Body water, extracellular water, body potassium, and exchangeable sodium in body builders using anabolic steroids

    International Nuclear Information System (INIS)

    Wang, J.; Colt, E.D.W.; Pierson, R.N. Jr.

    1986-01-01

    Nine competitive male body builders aged 21 to 34 who were determined to take anabolic steroids were studied before and 6 to 10 weeks after a training cycle which included steroid administration. A control group of nine subjects matched in age and duration of competitive career, but using only natural training methods were studied on a single occasion while in training. Total body potassium (TBK) by 40 K, total body water (TBW) by 3 H 2 O dilution, extracellular water (ECW) by 35 SO 4 dilution and zero time extrapolation, and exchangeable sodium by 24 Na dilution were measured before and after training. Intracellular water (ICW) was calculated from TBW - ECW. Initially steroid users had a greater skeletal muscle mass than control subjects, and obtained a further weight gain on steroids, all in skeletal muscle, based on parallel increases in TBK and ICW. Other body composition measurements did not change significantly. A single steroid user became ill taking steroids, decreased potassium by 5%, and increased extracellular water, changes which may represent the effects of hepatic dysfunction which occurred while on anabolic steroids

  19. Serum angiotensin-converting enzyme (SACE) activity as an indicator of total body granuloma load and prognosis in sarcoidosis.

    Science.gov (United States)

    Muthuswamy, P P; Lopez-Majano, V; Ranginwala, M; Trainor, W D

    1987-09-01

    The relationship between the level of serum angiotensin converting enzyme (SACE) and the total body granuloma load in patients with sarcoidosis was studied in two groups using SACE levels and total body gallium67 scans. The study group consisted of 22 patients with SACE levels greater than or equal to 100 U/ml (EH-SACE group) and the control group consisted of 24 patients consecutively diagnosed to have sarcoidosis in a one year period with SACE level of less than 80 U/ml. The average number of organs involved in the EH-SACE group was 3.9 +/- 1 compared to 2.3 +/- 1 in the control group (p less than 0.0001). The incidence of extra pulmonary organ involvement in the EH-SACE group was 2.2 +/- 1 organs compared to 1.0 + 0.8 in the control group (p less than 0.0002). The SACE level was correlated with the number of organs involved for all patients with sarcoidosis (r = .55; p less than .0001). Following corticosteroid therapy for 39 +/- 41 weeks the SACE dropped to 64 +/- 45 units in the EH-SACE group. But it took only 13 +/- 10 weeks to normalize the SACE level to 27 +/- 9 units in the control group. The EH-SACE group patients were followed for 114 +/- 64 weeks and 73% of them still have active sarcoidosis requiring repeated cycles of corticosteroid therapy, while after 42 +/- 23 weeks of follow up only 10% of patients from the control group were still on therapy.(ABSTRACT TRUNCATED AT 250 WORDS)

  20. Toward transferable interatomic van der Waals interactions without electrons: The role of multipole electrostatics and many-body dispersion

    International Nuclear Information System (INIS)

    Bereau, Tristan; Lilienfeld, O. Anatole von

    2014-01-01

    We estimate polarizabilities of atoms in molecules without electron density, using a Voronoi tesselation approach instead of conventional density partitioning schemes. The resulting atomic dispersion coefficients are calculated, as well as many-body dispersion effects on intermolecular potential energies. We also estimate contributions from multipole electrostatics and compare them to dispersion. We assess the performance of the resulting intermolecular interaction model from dispersion and electrostatics for more than 1300 neutral and charged, small organic molecular dimers. Applications to water clusters, the benzene crystal, the anti-cancer drug ellipticine—intercalated between two Watson-Crick DNA base pairs, as well as six macro-molecular host-guest complexes highlight the potential of this method and help to identify points of future improvement. The mean absolute error made by the combination of static electrostatics with many-body dispersion reduces at larger distances, while it plateaus for two-body dispersion, in conflict with the common assumption that the simple 1/R 6 correction will yield proper dissociative tails. Overall, the method achieves an accuracy well within conventional molecular force fields while exhibiting a simple parametrization protocol

  1. Toward transferable interatomic van der Waals interactions without electrons: The role of multipole electrostatics and many-body dispersion

    Energy Technology Data Exchange (ETDEWEB)

    Bereau, Tristan, E-mail: bereau@mpip-mainz.mpg.de [Max-Planck-Institut für Polymerforschung, Ackermannweg 10, 55128 Mainz, Germany and Department of Chemistry, University of Basel, 4056 Basel (Switzerland); Lilienfeld, O. Anatole von [Department of Chemistry, Institute of Physical Chemistry, University of Basel, 4056 Basel, Switzerland and Argonne Leadership Computing Facility, Argonne National Laboratory, Argonne, Illinois 60439 (United States)

    2014-07-21

    We estimate polarizabilities of atoms in molecules without electron density, using a Voronoi tesselation approach instead of conventional density partitioning schemes. The resulting atomic dispersion coefficients are calculated, as well as many-body dispersion effects on intermolecular potential energies. We also estimate contributions from multipole electrostatics and compare them to dispersion. We assess the performance of the resulting intermolecular interaction model from dispersion and electrostatics for more than 1300 neutral and charged, small organic molecular dimers. Applications to water clusters, the benzene crystal, the anti-cancer drug ellipticine—intercalated between two Watson-Crick DNA base pairs, as well as six macro-molecular host-guest complexes highlight the potential of this method and help to identify points of future improvement. The mean absolute error made by the combination of static electrostatics with many-body dispersion reduces at larger distances, while it plateaus for two-body dispersion, in conflict with the common assumption that the simple 1/R{sup 6} correction will yield proper dissociative tails. Overall, the method achieves an accuracy well within conventional molecular force fields while exhibiting a simple parametrization protocol.

  2. Total skin electron therapy treatment verification: Monte Carlo simulation and beam characteristics of large non-standard electron fields

    International Nuclear Information System (INIS)

    Pavon, Ester Carrasco; Sanchez-Doblado, Francisco; Leal, Antonio; Capote, Roberto; Lagares, Juan Ignacio; Perucha, Maria; Arrans, Rafael

    2003-01-01

    Total skin electron therapy (TSET) is a complex technique which requires non-standard measurements and dosimetric procedures. This paper investigates an essential first step towards TSET Monte Carlo (MC) verification. The non-standard 6 MeV 40 x 40 cm 2 electron beam at a source to surface distance (SSD) of 100 cm as well as its horizontal projection behind a polymethylmethacrylate (PMMA) screen to SSD = 380 cm were evaluated. The EGS4 OMEGA-BEAM code package running on a Linux home made 47 PCs cluster was used for the MC simulations. Percentage depth-dose curves and profiles were calculated and measured experimentally for the 40 x 40 cm 2 field at both SSD = 100 cm and patient surface SSD = 380 cm. The output factor (OF) between the reference 40 x 40 cm 2 open field and its horizontal projection as TSET beam at SSD = 380 cm was also measured for comparison with MC results. The accuracy of the simulated beam was validated by the good agreement to within 2% between measured relative dose distributions, including the beam characteristic parameters (R 50 , R 80 , R 100 , R p , E 0 ) and the MC calculated results. The energy spectrum, fluence and angular distribution at different stages of the beam (at SSD = 100 cm, at SSD = 364.2 cm, behind the PMMA beam spoiler screen and at treatment surface SSD = 380 cm) were derived from MC simulations. Results showed a final decrease in mean energy of almost 56% from the exit window to the treatment surface. A broader angular distribution (FWHM of the angular distribution increased from 13deg at SSD 100 cm to more than 30deg at the treatment surface) was fully attributable to the PMMA beam spoiler screen. OF calculations and measurements agreed to less than 1%. The effect of changing the electron energy cut-off from 0.7 MeV to 0.521 MeV and air density fluctuations in the bunker which could affect the MC results were shown to have a negligible impact on the beam fluence distributions. Results proved the applicability of using MC

  3. Image-guided total marrow and total lymphatic irradiation using helical tomotherapy

    International Nuclear Information System (INIS)

    Schultheiss, Timothy E.; Wong, Jeffrey; Liu, An; Olivera, Gustavo; Somlo, George

    2007-01-01

    Purpose: To develop a treatment technique to spare normal tissue and allow dose escalation in total body irradiation (TBI). We have developed intensity-modulated radiotherapy techniques for the total marrow irradiation (TMI), total lymphatic irradiation, or total bone marrow plus lymphatic irradiation using helical tomotherapy. Methods and Materials: For TBI, we typically use 12 Gy in 10 fractions delivered at an extended source-to-surface distance (SSD). Using helical tomotherapy, it is possible to deliver equally effective doses to the bone marrow and lymphatics while sparing normal organs to a significant degree. In the TMI patients, whole body skeletal bone, including the ribs and sternum, comprise the treatment target. In the total lymphatic irradiation, the target is expanded to include the spleen and major lymph node areas. Sanctuary sites for disease (brain and testes) are included when clinically indicated. Spared organs include the lungs, esophagus, parotid glands, eyes, oral cavity, liver, kidneys, stomach, small and large intestine, bladder, and ovaries. Results: With TBI, all normal organs received the TBI dose; with TMI, total lymphatic irradiation, and total bone marrow plus lymphatic irradiation, the visceral organs are spared. For the first 6 patients treated with TMI, the median dose to organs at risk averaged 51% lower than would be achieved with TBI. By putting greater weight on the avoidance of specific organs, greater sparing was possible. Conclusion: Sparing of normal tissues and dose escalation is possible using helical tomotherapy. Late effects such as radiation pneumonitis, veno-occlusive disease, cataracts, neurocognitive effects, and the development of second tumors should be diminished in severity and frequency according to the dose reduction realized for the organs at risk

  4. Cytoplasmic lipid bodies of human neutrophilic leukocytes

    International Nuclear Information System (INIS)

    Weller, P.F.; Ackerman, S.J.; Nicholson-Weller, A.; Dvorak, A.M.

    1989-01-01

    The morphology and function of cytoplasmic lipid bodies in human neutrophils were evaluated. By transmission electron microscopy, neutrophil lipid bodies were cytoplasmic inclusions, usually several microns in diameter, that occasionally coalesced to attain a diameter up to 7 microM. Neutrophil lipid bodies were not enveloped by membrane but were often surrounded by a more electron-dense shell at their periphery. Normal peripheral blood neutrophils contained an average of approximately one lipid body per cell. Lipid bodies appeared in greater numbers in neutrophils from inflammatory lesions. Perturbation of neutrophils during conventional methods of cell isolation and purification modestly increased lipid body numbers in neutrophils, whereas incubation of neutrophils with 1 microM oleic acid rapidly induced lipid body formation over 30 to 60 minutes. After granulocytes were incubated for 2 hours with 3H-fatty acids, including arachidonic, oleic, and palmitic acids, electron microscopic autoradiography demonstrated that lipid bodies represented the predominant intracellular sites of localization of each of the three 3H-fatty acids. There was lesser labeling noted in the perinuclear cisterna, but not in cell membranes. Virtually all of each of the three 3H-fatty acids incorporated by the neutrophils were esterified into chromatographically resolved classes of neutral lipids or phospholipids. These findings indicate that cytoplasmic lipid bodies are more prominent in neutrophils in vivo engaged in inflammatory responses and that these organelles in human neutrophils function as sites of deposition of esterified, incorporated fatty acids

  5. Dosimetry and verification of 60Co total body irradiation with human phantom and semiconductor diodes

    Directory of Open Access Journals (Sweden)

    Allahverdi Mahmoud

    2007-01-01

    Full Text Available Total Body Irradiation (TBI is a form of radiotherapy used for patients prior to bone marrow or stem cell transplant to destroy any undetectable cancer cells. The dosimetry characteristics of a 60 Co unit for TBI were studied and a simple method for the calculation of the prescribed dose for TBI is presented. Dose homogeneity was verified in a human phantom. Dose measurements were made in water phantom (30 x 30 x 30 cm 3 , using farmer ionization chamber (0.6 cc, TM30010, PTW and a parallel plate ionization chamber (TM23343, PTW. Point dose measurements for AP/PA irradiation were measured in a human phantom using silicon diodes (T60010L, PTW. The lung dose was measured with an ionization chamber (0.3 cc, TM31013. The validity of the proposed algorithm was checked at TBI distance using the human phantom. The accuracy of the proposed algorithm was within 3.5%. The dose delivered to the mid-lobe of the lung was 14.14 Gy and it has been reduced to 8.16 Gy by applying the proper shield. Dose homogeneity was within ±7% for all measured points. The results indicate that a good agreement between the total prescribed and calculated midplane doses can be achieved using this method. Therefore, it could be possible to use calculated data for TBI treatments.

  6. Severe Pulmonary Toxicity After Myeloablative Conditioning Using Total Body Irradiation: An Assessment of Risk Factors

    International Nuclear Information System (INIS)

    Kelsey, Chris R.; Horwitz, Mitchell E.; Chino, Junzo P.; Craciunescu, Oana; Steffey, Beverly; Folz, Rodney J.; Chao, Nelson J.; Rizzieri, David A.; Marks, Lawrence B.

    2011-01-01

    Purpose: To assess factors associated with severe pulmonary toxicity after myeloablative conditioning using total body irradiation (TBI) followed by allogeneic stem cell transplantation. Methods and Materials: A total of 101 adult patients who underwent TBI-based myeloablative conditioning for hematologic malignancies at Duke University between 1998 and 2008 were reviewed. TBI was combined with high-dose cyclophosphamide, melphalan, fludarabine, or etoposide, depending on the underlying disease. Acute pulmonary toxicity, occurring within 90 days of transplantation, was scored using Common Terminology Criteria for Adverse Events version 3.0. Actuarial overall survival and the cumulative incidence of acute pulmonary toxicity were calculated via the Kaplan-Meier method and compared using a log-rank test. A binary logistic regression analysis was performed to assess factors independently associated with acute severe pulmonary toxicity. Results: The 90-day actuarial risk of developing severe (Grade 3-5) pulmonary toxicity was 33%. Actuarial survival at 90 days was 49% in patients with severe pulmonary toxicity vs. 94% in patients without (p < 0.001). On multivariate analysis, the number of prior chemotherapy regimens was the only factor independently associated with development of severe pulmonary toxicity (odds ratio, 2.7 per regimen). Conclusions: Severe acute pulmonary toxicity is prevalent after TBI-based myeloablative conditioning regimens, occurring in approximately 33% of patients. The number of prior chemotherapy regimens appears to be an important risk factor.

  7. Absolute quantitative total-body small-animal SPECT with focusing pinholes

    International Nuclear Information System (INIS)

    Wu, Chao; Have, Frans van der; Vastenhouw, Brendan; Beekman, Freek J.; Dierckx, Rudi A.J.O.; Paans, Anne M.J.

    2010-01-01

    In pinhole SPECT, attenuation of the photon flux on trajectories between source and pinholes affects quantitative accuracy of reconstructed images. Previously we introduced iterative methods that compensate for image degrading effects of detector and pinhole blurring, pinhole sensitivity and scatter for multi-pinhole SPECT. The aim of this paper is (1) to investigate the accuracy of the Chang algorithm in rodents and (2) to present a practical Chang-based method using body outline contours obtained with optical cameras. Here we develop and experimentally validate a practical method for attenuation correction based on a Chang first-order method. This approach has the advantage that it is employed after, and therefore independently from, iterative reconstruction. Therefore, no new system matrix has to be calculated for each specific animal. Experiments with phantoms and animals were performed with a high-resolution focusing multi-pinhole SPECT system (U-SPECT-II, MILabs, The Netherlands). This SPECT system provides three additional optical camera images of the animal for each SPECT scan from which the animal contour can be estimated. Phantom experiments demonstrated that an average quantification error of -18.7% was reduced to -1.7% when both window-based scatter correction and Chang correction based on the body outline from optical images were applied. Without scatter and attenuation correction, quantification errors in a sacrificed rat containing sources with known activity ranged from -23.6 to -9.3%. These errors were reduced to values between -6.3 and +4.3% (with an average magnitude of 2.1%) after applying scatter and Chang attenuation correction. We conclude that the modified Chang correction based on body contour combined with window-based scatter correction is a practical method for obtaining small-animal SPECT images with high quantitative accuracy. (orig.)

  8. Emesis as a Screening Diagnostic for Low Dose Rate (LDR) Total Body Radiation Exposure.

    Science.gov (United States)

    Camarata, Andrew S; Switchenko, Jeffrey M; Demidenko, Eugene; Flood, Ann B; Swartz, Harold M; Ali, Arif N

    2016-04-01

    Current radiation disaster manuals list the time-to-emesis (TE) as the key triage indicator of radiation dose. The data used to support TE recommendations were derived primarily from nearly instantaneous, high dose-rate exposures as part of variable condition accident databases. To date, there has not been a systematic differentiation between triage dose estimates associated with high and low dose rate (LDR) exposures, even though it is likely that after a nuclear detonation or radiologic disaster, many surviving casualties would have received a significant portion of their total exposure from fallout (LDR exposure) rather than from the initial nuclear detonation or criticality event (high dose rate exposure). This commentary discusses the issues surrounding the use of emesis as a screening diagnostic for radiation dose after LDR exposure. As part of this discussion, previously published clinical data on emesis after LDR total body irradiation (TBI) is statistically re-analyzed as an illustration of the complexity of the issue and confounding factors. This previously published data includes 107 patients who underwent TBI up to 10.5 Gy in a single fraction delivered over several hours at 0.02 to 0.04 Gy min. Estimates based on these data for the sensitivity of emesis as a screening diagnostic for the low dose rate radiation exposure range from 57.1% to 76.6%, and the estimates for specificity range from 87.5% to 99.4%. Though the original data contain multiple confounding factors, the evidence regarding sensitivity suggests that emesis appears to be quite poor as a medical screening diagnostic for LDR exposures.

  9. Electron-positron correlations in an electron liquid

    International Nuclear Information System (INIS)

    Stachowiak, H.

    1980-01-01

    The importance of studying electron-positron interaction for the interpretation of angular correlation data obtained for metallic systems is emphasized. The most successful approaches to electron-positron correlations in jellium are presented. Those include the Bethe-Goldstone two-body equation proposed by Kahana, the charge-density-dielectric function approach connected with the names of Singwi, Sjolander, Stott and Bhattacharyya and the Sawada boson-generalized Tamm-Dancoff approach elaborated recently by Arponen and Pajanne. In conclusion, it is reported that one can consider that the behaviour of a positron at rest in jellium is relatively well understood, though the problem of the optimal choice of a two-body electron-positron phenomenological equation is still open. Also, the behaviour of a positron in a real metal is not well understood and so far, serious calculations in this field have been performed only on very simple models while realistic calculations of the ACPAQ curves tend to minimize the importance of the problems which remain to be solved. (K.B.)

  10. Weight and body mass index among female contraceptive clients.

    Science.gov (United States)

    Kohn, Julia E; Lopez, Priscilla M; Simons, Hannah R

    2015-06-01

    As obesity may affect the efficacy of some contraceptives, we examined weight, body mass index (BMI) and prevalence of obesity among female contraceptive clients at 231 U.S. health centers. A secondary aim was to analyze differences in contraceptive method use by obesity status. Cross-sectional study using de-identified electronic health record data from family planning centers. We analyzed contraceptive visits made by 147,336 females aged 15-44 years in 2013. A total of 46.1% of clients had BMI ≥25. Mean body weight was 154.4 lb (S.D.=41.9); mean BMI was 26.1 (S.D.=6.6). A total of 40% had BMI ≥26, when levonorgestrel emergency contraception may become less effective. Obese clients had higher odds of using a tier 1 or tier 3 contraceptive method and had lower odds of using a tier 2 or hormonal method than non-obese clients. About half of contraceptive clients would be categorized as overweight or obese. Contraceptive method choices differed by obesity status. About half of contraceptive clients in this study population were overweight or obese. Contraceptive method choices differed by obesity status. All women - regardless of body size - should receive unbiased, evidence-based counseling on the full range of contraceptive options so that they can make informed choices. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Ionization of atoms or ions by electron or proton impact; calculations with the classical three-body theory. ch. 3

    International Nuclear Information System (INIS)

    Boesten, L.G.J.

    1978-01-01

    Calculations on the threshold ionization of H, He + and Li 2+ by electrons have been performed to study the so-called 'post-collision interaction' (P.C.I.) effects which appear to affect the threshold ionization process significantly. These effects are caused by the long range Coulomb interactions between the two electrons as they move away from the nucleus. The long range interactions are fully taken into account in the classical three-body collision theory. In quantum mechanical theories, however, it is difficult to account for these interactions. This theory has been used to study the ionization of He + -ions by electron impact up to much higher energies (up till ten times the threshold energy). The results are compared with experimental results of Dolder et al. (1961) and with results of quantum mechanical calculations. Results are given for ionization of helium atoms by electron or proton impact. This collision process, in which four particles are involved, can under certain circumstances be treated as a collision process in which only three particles are involved. Calculations are performed concerning: a) cross sections for ionization of metastable helium atoms by electron impact, b) cross sections for ionization of ground-state helium atoms by fast proton impact (energy and angular distributions of ejected electrons), c) generalized oscillator strengths for ionization of helium by fast proton impact

  12. The association between body mass index and duration spent on electronic devices in children and adolescents in Western Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Abdulmoein E. Al-Agha

    2016-04-01

    Full Text Available Objectives: To evaluate the relationship between body mass index (BMI and the duration spent on electronic devices, and to assess the factors that can cause obesity among children. Methods: A cross-sectional study including 541 participants. Data was collected from March to June 2015 via ambulatory pediatric clinics in Jeddah, Kingdom of Saudi Arabia. The BMI standard deviation was calculated based on Center of Disease Control and Prevention (CDC standards. Results: The mean age of the participants was 10.1 years. Children who spent ≥2 hours daily on electronic devices showed an increased BMI, and made up 68.4% of the sample. Conclusion: An increased BMI was more common among children who spent ≥2 hours daily on electronic devices. The relationship between BMI, reduced physical activity, and eating during television viewing was determined.

  13. In vivo induction of apoptosis in human lymphocytes by therapeutic fractionated total body irradiation

    International Nuclear Information System (INIS)

    Delic, J.; Magdelenat, H.; Barbaroux, C.; Chaillet, M.-P.; Dubray, B.; Fourquet, A.; Cosset, J.-M.; Gluckman, E.; Girinsky, T.

    1995-01-01

    Ionizing radiations have been reported as an in vitro apoptosis initiating stimulus in human lymphocytes. As the cytotoxicity of ionizing radiations and chemotherapeutic agents appears to be dependent on the efficacy of cell death induction, the manipulation of apoptosis initiation might be used as a means to suppress some pathological process. In the present study the in vivo induction of γ-ray mediated programmed cell death in humans is reported. The in vivo induction of apoptosis in peripheral blood lymphocytes (PBL) by ionizing radiations was investigated in 33 patients after each of two sessions (2 Gy and 4 Gy) of fractionated total body irradiation (FTBI) as part of their conditioning regimen before bone marrow transplantation. PBL committed to apoptosis were scored before irradiation (S1), 4 h (S2) and 24 h after 2 Gy (S3, 14-17 h after the second 2 Gy fraction). Nuclear morphology and chromatin-DNA were analysed by fluorescence microscopy immediately after blood sample withdrawal (I) and after 24 h in cell culture medium (II). (author)

  14. Prospective neurodevelopmental studies of two children treated with total body irradiation and bone marrow transplantation for acute leukemia in infancy

    International Nuclear Information System (INIS)

    Kaleita, T.; Tesler, A.; Feig, S.A.

    1987-01-01

    Five-year neurodevelopmental studies of two infants with acute leukemia are presented. Both patients underwent bone marrow transplantation (BMT) after conditioning with cyclophosphamide and total body irradiation (TBI). Neither patient was treated with intrathecal chemotherapy. Their outcome is remarkable for normal development of intelligence, language, perception, and motor coordination. These results suggest that TBI and BMT should be considered in future therapeutic studies of infants with acute leukemia, who are at great risk for failure of conventional therapy

  15. [Intracardial fungal multiplication of order Mucor in an almost totally carbonised part of a male body found after ten days missing].

    Science.gov (United States)

    Iannaccone, Silvia Farkašová; Klán, Jaroslav; Lamps, Laura W; Farkaš, Daniel; Švajdler Ml, Marián; Szabo, Miroslav

    Determination of time of death belongs to the most difficult and also the most important issues for the medical examiners, especially those who deal with violent death. Besides the most frequently evaluated postmortal changes it is sometimes possible to perform the evaluation on the basis of less frequently observed findings. One of such findings is for example the fungal multiplication on the body or in the very close vicinity. Knowledge of moulds as well as information about their speed of growth should contribute to confirmation or negation of some information gained during police investigation. In this case report authors describe the macroscopically visible fungal intracardiac multiplication in heart chambers and aorta in an almost totally carbonised body which was missing for only ten days. Based on the molecular examination it was detected that the body belonged to the 64-year-old man who was repeatedly hospitalised in psychiatry for depression with suicidal tendencies. The last hospitalisation was six weeks before death and there was no organic disability. The cause of fire was a naked flame. The cause of death was burn injury or asphyxia. The almost total carbonisation did not allow to perform toxicological investigation. By histological investigation we found the presence of wide long non-septate moulds growing in the heart muscle, which belonged to the order Mucor. Since there was no obvious inflammatory response, we suppose their growth started on the congealed blood after death.

  16. Electron-electron correlation in two-photon double ionization of He-like ions

    Science.gov (United States)

    Hu, S. X.

    2018-01-01

    Electron correlation plays a crucial role in quantum many-body physics ranging from molecular bonding and strong-field-induced multielectron ionization, to superconducting in materials. Understanding the dynamic electron correlation in the photoionization of relatively simple quantum three-body systems, such as He and He-like ions, is an important step toward manipulating complex systems through photoinduced processes. Here we have performed ab initio investigations of two-photon double ionization (TPDI) of He and He-like ions (L i+,B e2 + , and C4 +) exposed to intense attosecond x-ray pulses. Results from such fully correlated quantum calculations show weaker and weaker electron correlation effects in TPDI spectra as the ionic charge increases, which is opposite to the intuition that the absolute increase of correlation in the ground state should lead to more equal energy sharing in photoionization. These findings indicate that the final-state electron-electron correlation ultimately determines the energy sharing of the two ionized electrons in TPDI.

  17. Resistance Training with Single vs. Multi-joint Exercises at Equal Total Load Volume: Effects on Body Composition, Cardiorespiratory Fitness, and Muscle Strength.

    Science.gov (United States)

    Paoli, Antonio; Gentil, Paulo; Moro, Tatiana; Marcolin, Giuseppe; Bianco, Antonino

    2017-01-01

    The present study aimed to compare the effects of equal-volume resistance training performed with single-joint (SJ) or multi-joint exercises (MJ) on VO 2 max, muscle strength and body composition in physically active males. Thirty-six participants were divided in two groups: SJ group ( n = 18, 182.1 ± 5.2, 80.03 ± 2.78 kg, 23.5 ± 2.7 years) exercised with only SJ exercises (e.g., dumbbell fly, knee extension, etc.) and MJ group ( n = 18, 185.3 ± 3.6 cm, 80.69 ± 2.98 kg, 25.5 ± 3.8 years) with only MJ exercises (e.g., bench press, squat, etc.). The total work volume (repetitions × sets × load) was equated between groups. Training was performed three times a week for 8 weeks. Before and after the training period, participants were tested for VO 2 max, body composition, 1 RM on the bench press, knee extension and squat. Analysis of covariance (ANCOVA) was used to compare post training values between groups, using baseline values as covariates. According to the results, both groups decreased body fat and increased fat free mass with no difference between them. Whilst both groups significantly increased cardiorespiratory fitness and maximal strength, the improvements in MJ group were higher than for SJ in VO 2 max (5.1 and 12.5% for SJ and MJ), bench press 1 RM (8.1 and 10.9% for SJ and MJ), knee extension 1 RM (12.4 and 18.9% for SJ and MJ) and squat 1 RM (8.3 and 13.8% for SJ and MJ). In conclusion, when total work volume was equated, RT programs involving MJ exercises appear to be more efficient for improving muscle strength and maximal oxygen consumption than programs involving SJ exercises, but no differences were found for body composition.

  18. Resistance Training with Single vs. Multi-joint Exercises at Equal Total Load Volume: Effects on Body Composition, Cardiorespiratory Fitness, and Muscle Strength

    Directory of Open Access Journals (Sweden)

    Antonio Paoli

    2017-12-01

    Full Text Available The present study aimed to compare the effects of equal-volume resistance training performed with single-joint (SJ or multi-joint exercises (MJ on VO2max, muscle strength and body composition in physically active males. Thirty-six participants were divided in two groups: SJ group (n = 18, 182.1 ± 5.2, 80.03 ± 2.78 kg, 23.5 ± 2.7 years exercised with only SJ exercises (e.g., dumbbell fly, knee extension, etc. and MJ group (n = 18, 185.3 ± 3.6 cm, 80.69 ± 2.98 kg, 25.5 ± 3.8 years with only MJ exercises (e.g., bench press, squat, etc.. The total work volume (repetitions × sets × load was equated between groups. Training was performed three times a week for 8 weeks. Before and after the training period, participants were tested for VO2max, body composition, 1 RM on the bench press, knee extension and squat. Analysis of covariance (ANCOVA was used to compare post training values between groups, using baseline values as covariates. According to the results, both groups decreased body fat and increased fat free mass with no difference between them. Whilst both groups significantly increased cardiorespiratory fitness and maximal strength, the improvements in MJ group were higher than for SJ in VO2max (5.1 and 12.5% for SJ and MJ, bench press 1 RM (8.1 and 10.9% for SJ and MJ, knee extension 1 RM (12.4 and 18.9% for SJ and MJ and squat 1 RM (8.3 and 13.8% for SJ and MJ. In conclusion, when total work volume was equated, RT programs involving MJ exercises appear to be more efficient for improving muscle strength and maximal oxygen consumption than programs involving SJ exercises, but no differences were found for body composition.

  19. Simvastatin mitigates increases in risk factors for and the occurrence of cardiac disease following 10 Gy total body irradiation.

    Science.gov (United States)

    Lenarczyk, Marek; Su, Jidong; Haworth, Steven T; Komorowski, Richard; Fish, Brian L; Migrino, Raymond Q; Harmann, Leanne; Hopewell, John W; Kronenberg, Amy; Patel, Shailendra; Moulder, John E; Baker, John E

    2015-06-01

    The ability of simvastatin to mitigate the increases in risk factors for and the occurrence of cardiac disease after 10 Gy total body irradiation (TBI) was determined. This radiation dose is relevant to conditioning for stem cell transplantation and threats from radiological terrorism. Male rats received single dose TBI of 10 Gy. Age-matched, sham-irradiated rats served as controls. Lipid profile, heart and liver morphology and cardiac mechanical function were determined for up to 120 days after irradiation. TBI resulted in a sustained increase in total- and LDL-cholesterol (low-density lipoprotein-cholesterol), and triglycerides. Simvastatin (10 mg/kg body weight/day) administered continuously from 9 days after irradiation mitigated TBI-induced increases in total- and LDL-cholesterol and triglycerides, as well as liver injury. TBI resulted in cellular peri-arterial fibrosis, whereas control hearts had less collagen and fibrosis. Simvastatin mitigated these morphological injuries. TBI resulted in cardiac mechanical dysfunction. Simvastatin mitigated cardiac mechanical dysfunction 20-120 days following TBI. To determine whether simvastatin affects the ability of the heart to withstand stress after TBI, injury from myocardial ischemia/reperfusion was determined in vitro. TBI increased the severity of an induced myocardial infarction at 20 and 80 days after irradiation. Simvastatin mitigated the severity of this myocardial infarction at 20 and 80 days following TBI. It is concluded simvastatin mitigated the increases in risk factors for cardiac disease and the extent of cardiac disease following TBI. This statin may be developed as a medical countermeasure for the mitigation of radiation-induced cardiac disease.

  20. Observations in equatorial anomaly region of total electron content enhancements and depletions

    Directory of Open Access Journals (Sweden)

    N. Dashora

    2005-10-01

    Full Text Available A GSV 4004A GPS receiver has been operational near the crest of the equatorial anomaly at Udaipur, India for some time now. The receiver provides the line-of-sight total electron content (TEC, the phase and amplitude scintillation index, σφ and S4, respectively. This paper presents the first results on the nighttime TEC depletions associated with the equatorial spread F in the Indian zone. The TEC depletions are found to be very well correlated with the increased S4 index. A new feature of low-latitude TEC is also reported, concerning the observation of isolated and localized TEC enhancements in the nighttime low-latitude ionosphere. The TEC enhancements are not correlated with the S4 index. The TEC enhancements have also been observed along with the TEC depletions. The TEC enhancements have been interpreted as the manifestation of the plasma density enhancements reported by Le et al. (2003.

    Keywords. Ionosphere (Equatorial ionosphere; Ionospheric irregularities

  1. Total Skin Electron Beam for Primary Cutaneous T-cell Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Elsayad, Khaled; Kriz, Jan; Moustakis, Christos; Scobioala, Sergiu; Reinartz, Gabriele; Haverkamp, Uwe; Willich, Normann [Department of Radiation Oncology, University Hospital of Muenster, Muenster (Germany); Weishaupt, Carsten [Department of Dermatology, University Hospital of Muenster, Muenster (Germany); Stadler, Rudolf [Department of Dermatology, Johannes-Wesling-Klinikum Minden, Minden (Germany); Sunderkötter, Cord [Department of Dermatology, University Hospital of Muenster, Muenster (Germany); Eich, Hans Theodor, E-mail: Hans.Eich@ukmuenster.de [Department of Radiation Oncology, University Hospital of Muenster, Muenster (Germany)

    2015-12-01

    Purpose: Recent trials with low-dose total skin electron beam (TSEB) therapy demonstrated encouraging results for treating primary cutaneous T-cell lymphoma (PCTCL). In this study, we assessed the feasibility of different radiation doses and estimated survival rates of different pathologic entities and stages. Methods and Materials: We retrospectively identified 45 patients with PCTCL undergoing TSEB therapy between 2000 and 2015. Clinical characteristics, treatment outcomes, and toxicity were assessed. Results: A total of 49 courses of TSEB therapy were administered to the 45 patients. There were 26 pathologically confirmed cases of mycosis fungoides (MF) lymphoma, 10 cases of Sézary syndrome (SS), and 9 non-MF/SS PCTCL patients. In the MF patients, the overall response rate (ORR) was 92% (50% complete remission [CR]), 70% ORR in SS patients (50% CR), and 89% ORR in non-MF/SS patients (78% CR). The ORR for MF/SS patients treated with conventional dose (30-36 Gy) regimens was 92% (63% CR) and 75% (25% CR) for low-dose (<30-Gy) regimens (P=.09). In MF patients, the overall survival (OS) was 77 months with conventional dose regimens versus 14 months with low-dose regimens (P=.553). In SS patients, the median OS was 48 versus 16 months (P=.219), respectively. Median event-free survival (EFS) for MF in conventional dose patients versus low-dose patients was 15 versus 8 months, respectively (P=.264) and 19 versus 3 months for SS patients (P=.457). Low-dose regimens had shorter treatment time (P=.009) and lower grade 2 adverse events (P=.043). A second TSEB course was administered in 4 MF patients with 100% ORR. There is a possible prognostic impact of supplemental/boost radiation (P<.001); adjuvant treatment (P<.001) and radiation tolerability (P=.021) were detected. Conclusions: TSEB therapy is an efficacious treatment modality in the treatment of several forms of cutaneous T-cell lymphoma. There is a nonsignificant trend to higher and longer clinical benefit

  2. Impact of body habitus on quantitative and qualitative image quality in whole-body FDG-PET

    Energy Technology Data Exchange (ETDEWEB)

    Tatsumi, Mitsuaki; Clark, Paul A.; Nakamoto, Yuji; Wahl, Richard L. [Division of Nuclear Medicine, Department of Radiology, The Johns Hopkins Medical Institutions, 601 N. Caroline St., Rm 3223, Baltimore, MD 21287-0817 (United States)

    2003-01-01

    Obtaining consistent high image quality is desirable for clinical positron emission tomography (PET). Body morphology may impact image quality. The purpose of this study was to define the average and the range of body sizes in patients undergoing tumor PET studies in our center and to determine how the body habitus affects the statistical and visual quality of PET images. Height, weight, body surface area (BSA), and body mass index (BMI) were determined in 101 male and 101 female patients (group 1) referred for clinical PET. The summed total counts from three consecutive transaxial slices on non-attenuation-corrected (NAC) 2D fluorine-18 fluorodeoxyglucose (FDG) PET images, which included the largest liver section and no lesions, were determined and compared with body morphology and injected doses (ID) in a representative group of 30 male and 30 female patients (group 2) spanning a range of body morphologies. The visual quality of images was also evaluated using a scoring system by three readers. The average height, weight, and BSA were greater in male than in female patients, but the average BMI was not different between them in group 1. The largest value of weight or BMI was more than four times the smallest value in female patients. The total true counts were best correlated with ID/weight (mCi/kg) in group 2 (r=0.929, P<0.0001). Intermediate to high total counts (930,000 or more) corresponded to ID/weight of 0.22 or higher. The average visual score was positively correlated with the total counts ({rho}=0.63, P<0.0001) and with ID/weight ({rho}=0.68, P<0.0001) on NAC images. The image quality in 22 (84.6%) of 26 patients with intermediate to high total counts was adequate to good, whereas that in 21 (61.8%) of 34 patients with lower total counts was suboptimal. A wide variety of body morphologies was observed in patients referred for clinical FDG-PET tumor studies in our center. The total counts and average image visual score were negatively correlated with

  3. Total body irradiation with a compensator fabricated using a 3D optical scanner and a 3D printer.

    Science.gov (United States)

    Park, So-Yeon; Kim, Jung-In; Joo, Yoon Ha; Lee, Jung Chan; Park, Jong Min

    2017-05-07

    We propose bilateral total body irradiation (TBI) utilizing a 3D printer and a 3D optical scanner. We acquired surface information of an anthropomorphic phantom with the 3D scanner and fabricated the 3D compensator with the 3D printer, which could continuously compensate for the lateral missing tissue of an entire body from the beam's eye view. To test the system's performance, we measured doses with optically stimulated luminescent dosimeters (OSLDs) as well as EBT3 films with the anthropomorphic phantom during TBI without a compensator, conventional bilateral TBI, and TBI with the 3D compensator (3D TBI). The 3D TBI showed the most uniform dose delivery to the phantom. From the OSLD measurements of the 3D TBI, the deviations between the measured doses and the prescription dose ranged from  -6.7% to 2.4% inside the phantom and from  -2.3% to 0.6% on the phantom's surface. From the EBT3 film measurements, the prescription dose could be delivered to the entire body of the phantom within  ±10% accuracy, except for the chest region, where tissue heterogeneity is extreme. The 3D TBI doses were much more uniform than those of the other irradiation techniques, especially in the anterior-to-posterior direction. The 3D TBI was advantageous, owing to its uniform dose delivery as well as its efficient treatment procedure.

  4. Simulation of non-equilibrium many body electrons in RTD

    Directory of Open Access Journals (Sweden)

    A. H. Rezvani

    2001-06-01

    Full Text Available   We inspected the exact solution of double barrier quantum well. The choice of proper boundary conditions has been taken into account. We eveluated the mechanism of resonant in this device. The density correlation matrix was calculated by using the exact solution of the time-dependent generalized nonlinear Schrodinger equation in the presence of electron-electron interaction. The result shows that there is no correlation dependence among the electrons at the equilibrium between contact regions. After biasing, we have calculated the density correlation matrix in the transient and steady state. The results of our calculations show the oscillatory plasmon current in the state of transient, while in the steaby state the correlation among the phase of electrons observed to be oscillatory in the whole region of the device.

  5. Elucidation of the electronic states in polyethylene glycol by attenuated Total reflectance spectroscopy in the far-ultraviolet region

    Science.gov (United States)

    Ueno, Nami; Wakabayashi, Tomonari; Morisawa, Yusuke

    2018-05-01

    We measured the attenuated total reflectance-far ultraviolet (ATR-FUV) spectra of poly(ethylene glycol) (PEG; average molecular weights of 200, 300, and 400) and related materials in the liquid state in the 145-200-nm wavelength region. For appropriately assigning the absorption bands, we also performed theoretical simulation of the unit-number dependent electronic spectra. The FUV spectra of PEGs contain three bands, which are assigned to the transitions between n(CH2OCH2)-3s Rydberg state (176 nm), n(CH2OCH2)-3p Rydberg state (163 nm), and n(OH)-3p Rydberg state (153 nm). Since the contribution of n(OH) decreases compared to n(CH2OCH2) with increase in the number of units, the ratios of the molar absorption coefficients, ε, at 153 nm relative to 163 nm, decrease. On the other hand, the ratio of ε at 176 nm to that at 163 nm increases with increase in the number of units, because of the difference in the number of unoccupied orbitals in the transitions. The calculated results suggest that n orbitals form two electronic bands. In the upper band, the electrons expand over the ether chain, whereas in the lower band, the electrons are localized in the terminal OH in the PEGs.

  6. Effect of electrojet on the total electron content of the ionosphere over the Indian subcontinent

    International Nuclear Information System (INIS)

    Deshpande, M.R.; Rastogi, R.G.; Vats, H.O.

    1977-01-01

    It is stated that the satellite radio beacon method of measuring total electron content (TEC) along a chain of spaced stations near the 'equatorial anomaly' has been used to continuously monitor the latitudinal extent of the anomaly. A clear dependence of the strength of the anomaly upon the electrojet intensity, with an approximately two-hour time delay, was established. By 'equatorial anomaly' is meant the anomalous latitudinal distribution of electron density in the F2 region, as observed by Appleton (J. Atmos. Terr. Phys.; 5:348 (1954)). It has been shown that the equatorial anomaly in TEC over India is positively correlated with the electrojet strength. Observations of the diurnal development of the equatorial anomaly in TEC are here described, together with magnetometer records indicating the strength of the equatorial electrojet, leading to records of the TEC anomaly. The observations were made on three days in May 1976, using radio beacon signals from the geostationary satellite ATS-6 received at a number of locations in India. Association of the diurnal development of the equatorial anomaly in TEC with electrojet strength were clearly established. (U.K.)

  7. Body composition during weight loss in obese patients estimated by dual energy X-ray absorptiometry and by total body potassium

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Andersen, T

    1996-01-01

    for FFM were strong (r = 0.92 and 0.93). Bland and Altman plots showed limits of agreement of +/-9 kg before and after weight loss; DXA underestimated FFM in women and overestimated FFM in men. DXA accounted for 80% of the lost body weight. The composition of the lost body mass did not differ from...... that estimated by TBK (7.6% FFM and 92.4% FM by TBK; 11% FFM and 89% FM by DXA). CONCLUSION: DXA estimates accurately the body composition and the composition of weight loss in groups of obese subjects. However, the scan table may be too small for patients weighing more than 95 kg....

  8. Relationship of total body fat mass to weight-bearing bone volumetric density, geometry, and strength in young girls.

    Science.gov (United States)

    Farr, Joshua N; Chen, Zhao; Lisse, Jeffrey R; Lohman, Timothy G; Going, Scott B

    2010-04-01

    Understanding the influence of total body fat mass (TBFM) on bone during the peri-pubertal years is critical for the development of future interventions aimed at improving bone strength and reducing fracture risk. Thus, we evaluated the relationship of TBFM to volumetric bone mineral density (vBMD), geometry, and strength at metaphyseal and diaphyseal sites of the femur and tibia of young girls. Data from 396 girls aged 8-13 years from the "Jump-In: Building Better Bones" study were analyzed. Bone parameters were assessed using peripheral quantitative computed tomography (pQCT) at the 4% and 20% distal femur and 4% and 66% distal tibia of the non-dominant leg. Bone parameters at the 4% sites included trabecular vBMD, periosteal circumference, and bone strength index (BSI), while at the 20% femur and 66% tibia, parameters included cortical vBMD, periosteal circumference, and strength-strain index (SSI). Multiple linear regression analyses were used to assess associations between bone parameters and TBFM, controlling for muscle cross-sectional area (MCSA). Regression analyses were then repeated with maturity, bone length, physical activity, and ethnicity as additional covariates. Analysis of covariance (ANCOVA) was used to compare bone parameters among tertiles of TBFM. In regression models with TBFM and MCSA, associations between TBFM and bone parameters at all sites were not significant. TBFM explained very little variance in all bone parameters (0.2-2.3%). In contrast, MCSA was strongly related (p<0.001) to all bone parameters, except cortical vBMD. The addition of maturity, bone length, physical activity, and ethnicity did not alter the relationship between TBFM and bone parameters. With bone parameters expressed relative to total body mass, ANCOVA showed that all outcomes were significantly (p<0.001) greater in the lowest compared to the middle and highest tertiles of TBFM. Although TBFM is correlated with femur and tibia vBMD, periosteal circumference, and

  9. Analytical formulae for total cross sections for electron scattering by atoms (N, O, F, Ne, P, S, Cl, Ar, As, Se, Br, Kr) between 0.5-10 keV

    International Nuclear Information System (INIS)

    Williart, A.

    2001-01-01

    Analytical formulae for total cross sections for electron scattering by atoms which are close to the noble gases (Ne, Ar and Kr), for electron energies ranging from 0.5 to 10 keV, have been obtained in this study. We have shown, previously, that molecular total cross sections, at these energies, depend on target polarizability and the number of target electrons. A similar behaviour has been supposed for total cross sections of some atoms (N, O, F, P, S, Cl, As, Se and Br). The obtained expression depends on atomic parameters and it is based in some correlation derived from noble gases. The applicability of the formula has been checked by comparison with available data for atomic oxygen. (orig.)

  10. Analytical formulae for total cross sections for electron scattering by atoms (N, O, F, Ne, P, S, Cl, Ar, As, Se, Br, Kr) between 0.5-10 keV

    Energy Technology Data Exchange (ETDEWEB)

    Williart, A. [Univ. Nacional de Educacion a Distancia, Madrid (Spain). Dept. de Fisica de los Materiales; Garcia, G. [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas, Madrid (Spain)

    2001-10-01

    Analytical formulae for total cross sections for electron scattering by atoms which are close to the noble gases (Ne, Ar and Kr), for electron energies ranging from 0.5 to 10 keV, have been obtained in this study. We have shown, previously, that molecular total cross sections, at these energies, depend on target polarizability and the number of target electrons. A similar behaviour has been supposed for total cross sections of some atoms (N, O, F, P, S, Cl, As, Se and Br). The obtained expression depends on atomic parameters and it is based in some correlation derived from noble gases. The applicability of the formula has been checked by comparison with available data for atomic oxygen. (orig.)

  11. Different encapsulation strategies for implanted electronics

    Directory of Open Access Journals (Sweden)

    Winkler Sebastian

    2017-09-01

    Full Text Available Recent advancements in implant technology include increasing application of electronic systems in the human body. Hermetic encapsulation of electronic components is necessary, specific implant functions and body environments must be considered. Additional functions such as wireless communication systems require specialized technical solutions for the encapsulation.

  12. Treatment of chronic granulocytic leukemia by chemotherapy, total body irradiation and allogeneic bone marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Doney, K; Buckner, C D; Sale, G E; Ramberg, R; Boyd, C; Thomas, E D [Fred Hutchinson Cancer Research Institute; Washington Univ., Seattle (USA). School of Medicine)

    1978-01-01

    Fourteen patients with chronic granulocytic leukemia received bone marrow grafts from HLA identical siblings. Ten patients were in blast crisis prior to grafting, three were in an accelerated phase of their disease, and one was aplastic secondary to chemotherapy. Prior to transplant all patients were conditioned with chemotherapy including cyclophosphamide plus 1,000 rad of total body irradiation. Ten patients achieved engraftment while four died 1 to 26 days after marrow infusion without functioning grafts. Two patients reveived a second infusion of donor marrow because of delayed engraftment. Neither marrow cell dose nor presence of myelofibrosis correlated with succesful engraftment. Three out of ten engrafted patients developed graft-versus-host disease. Interstitial pneumonia occurred in seven patients. The immediate cause of death was bacterial septicemia in six patients. All evidence of leukemia disappeared in nine out of ten evaluable patients. The median survival was 43 days. One patient had a complete remission of 16 months duration.

  13. Treatment of chronic granulocytic leukemia by chemotherapy, total body irradiation and allogeneic bone marrow transplantation

    International Nuclear Information System (INIS)

    Doney, K.; Buckner, C.D.; Sale, G.E.; Ramberg, R.; Boyd, C.; Thomas, E.D.; Washington Univ., Seattle

    1978-01-01

    Fourteen patients with chronic granulocytic leukemia received bone marrow grafts from HLA identical siblings. Ten patients were in blast crisis prior to grafting, three were in an accelerated phase of their disease, and one was aplastic secondary to chemotherapy. Prior to transplant all patients were conditioned with chemotherapy including cyclophosphamide plus 1,000 rad of total body irradiation. Ten patients achieved engraftment while four died 1 to 26 days after marrow infusion without functioning grafts. Two patients reveived a second infusion of donor marrow because of delayed engraftment. Neither marrow cell dose nor presence of myelofibrosis correlated with succesful engraftment. Three out of ten engrafted patients developed graft-versus-host disease. Interstitial pneumonia occurred in seven patients. The immediate cause of death was bacterial septicemia in six patients. All evidence of leukemia disappeared in nine out of ten evaluable patients. The median survival was 43 days. One patient had a complete remission of 16 months duration. (Author)

  14. Effect of High-Intensity Interval Training on Total, Abdominal and Visceral Fat Mass: A Meta-Analysis.

    Science.gov (United States)

    Maillard, Florie; Pereira, Bruno; Boisseau, Nathalie

    2018-02-01

    High-intensity interval training (HIIT) is promoted as a time-efficient strategy to improve body composition. The aim of this meta-analysis was to assess the efficacy of HIIT in reducing total, abdominal, and visceral fat mass in normal-weight and overweight/obese adults. Electronic databases were searched to identify all related articles on HIIT and fat mass. Stratified analysis was performed using the nature of HIIT (cycling versus running, target intensity), sex and/or body weight, and the methods of measuring body composition. Heterogeneity was also determined RESULTS: A total of 39 studies involving 617 subjects were included (mean age 38.8 years ± 14.4, 52% females). HIIT significantly reduced total (p = 0.003), abdominal (p = 0.007), and visceral (p = 0.018) fat mass, with no differences between the sexes. A comparison showed that running was more effective than cycling in reducing total and visceral fat mass. High-intensity (above 90% peak heart rate) training was more successful in reducing whole body adiposity, while lower intensities had a greater effect on changes in abdominal and visceral fat mass. Our analysis also indicated that only computed tomography scan or magnetic resonance imaging showed significant abdominal and/or visceral fat-mass loss after HIIT interventions. HIIT is a time-efficient strategy to decrease fat-mass deposits, including those of abdominal and visceral fat mass. There was some evidence of the greater effectiveness of HIIT running versus cycling, but owing to the wide variety of protocols used and the lack of full details about cycling training, further comparisons need to be made. Large, multicenter, prospective studies are required to establish the best HIIT protocols for reducing fat mass according to subject characteristics.

  15. ACPSEM ROSG TBI working group recommendations for quality assurance in total body irradiation

    International Nuclear Information System (INIS)

    Nelligan, Raelene; Bailey, Michael; Tran, Thu; Baldwin, Zoe

    2015-01-01

    The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) radiation oncology specialty group (ROSG) formed a series of working groups in 2011 to develop recommendations for guidance of radiation oncology medical physics practice within the Australasian setting. These recommendations are intended to provide guidance for safe work practices and a suitable level of quality control without detailed work instructions. It is the responsibility of the medical physicist to ensure that locally available equipment and procedures are sufficiently sensitive to establish compliance to these recommendations. The recommendations are endorsed by the ROSG, and have been subject to independent expert reviews. For the Australian audience, these recommendations should be read in conjunction with the tripartite radiation oncology practice standards [1, 2]. This publication presents the recommendations of the ACPSEM total body irradiation working group (TBIWG) and has been developed in alignment with other international associations. However, these recommendations should be read in conjunction with relevant national, state or territory legislation and local requirements, which take precedence over the ACPSEM recommendations. It is hoped that the users of this and other ACPSEM recommendations will contribute to the development of future versions through the ROSG of the ACPSEM. This document serves as a guideline for calibration and quality assurance of equipment used for TBI in Australasia.

  16. The enhanced total body wrap--the new frontier in dressing care for burns.

    Science.gov (United States)

    Low, O-Wern; Chong, Si Jack; Tan, Bien-Keem

    2013-11-01

    The management of extensive burns with their associated high fluid exudate following burn excision and skin grafting has always posed a challenge in burn wound care. The ideal dressing should protect the wound from physical damage and micro-organisms; be comfortable and durable; allow high humidity at the wound; and be able to allow maximal activity for wound healing without retarding or inhibiting any stage of the process. The dressing technique described in this paper fulfils all the criteria above and at the same time provides an efficient channel to effectively clear the excessive exudate produced while keeping the wounds moist. Advantages conferred include accurate charting of wound exudate; reduced frequency of dressing changes; lower infection rates through prevention of strike-through; and securing and improving the viability of skin grafts. An enhancement to a technique previously described by us through the use of long thin strips of VAC sponges to transmit negative pressure, the enhanced Total Body Wrap aims to provide ideal conditions to promote healing in burns. Using negative pressure wound therapy (NPWT), this technique is simple and straightforward enough to be applied in majority of tertiary centres around the world. Copyright © 2013. Published by Elsevier Ltd.

  17. Interplay between electron-phonon and electron-electron interactions

    International Nuclear Information System (INIS)

    Roesch, O.; Gunnarsson, O.; Han, J.E.; Crespi, V.H.

    2005-01-01

    We discuss the interplay between electron-electron and electron-phonon interactions for alkali-doped fullerides and high temperature superconductors. Due to the similarity of the electron and phonon energy scales, retardation effects are small for fullerides. This raises questions about the origin of superconductivity, since retardation effects are believed to be crucial for reducing effects of the Coulomb repulsion in conventional superconductors. We demonstrate that by treating the electron-electron and electron-phonon interactions on an equal footing, superconductivity can be understood in terms of a local pairing. The Jahn-Teller character of the important phonons in fullerides plays a crucial role for this result. To describe effects of phonons in cuprates, we derive a t-J model with phonons from the three-band model. Using exact diagonalization for small clusters, we find that the anomalous softening of the half-breathing phonon as well as its doping dependence can be explained. By comparing the solution of the t-J model with the Hartree-Fock approximation for the three-band model, we address results obtained in the local-density approximation for cuprates. We find that genuine many-body results, due to the interplay between the electron-electron and electron-phonon interactions, play an important role for the the results in the t-J model. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  18. Immunoglobulin levels in dogs after total-body irradiation and bone marrow transplantation

    International Nuclear Information System (INIS)

    Vriesendorp, H.M.; Halliwell, R.E.; Johnson, P.M.; Fey, T.A.; McDonough, C.M.

    1985-01-01

    The influence of total-body irradiation (TBI) and autologous or allogeneic bone marrow transplantation on serum immunoglobulin subclasses was determined in a dog model. Only IgG1 levels decreased after low-dose (+/- 4.5 Gy) TBI, but levels of all immunoglobulin classes fell after high-dose TBI (8.5 GyX1 or 2X6.0 Gy). After autologous bone marrow transplantation IgM levels were the first and IgE levels were the last to return to normal. After successful allogeneic bone marrow transplantation prolonged low IgM and IgE levels were found but IgA levels increased rapidly to over 150% of pretreatment values. A comparison of dogs with or without clinical signs or graft-versus-host disease (GVHD), revealed no differences in IgM levels. Dogs with GVHD had higher IgA but lower IgE levels. Dogs that rejected their allogeneic bone marrow cells showed significant early rises in IgE and IgA levels in comparison with dogs with GVHD. These results differ from the observations made on Ig levels in human bone marrow transplant patients. No significant differences in phytohemagglutinin stimulation tests were found between dogs with or without GVHD or dogs receiving an autologous transplant for the first four months after TBI and transplantation. An early primary or secondary involvement of humoral immunity in GVHD and graft rejection in dogs is postulated

  19. Biologically effective dose in total-body irradiation and hematopoietic stem cell transplantation

    International Nuclear Information System (INIS)

    Kal, H.B.; Kempen-Harteveld, M.L. van; Heijenbrok-Kal, M.H.; Struikmans, H.

    2006-01-01

    Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were pooled, and the pooled relative risk (RR) was calculated for the treatments with high BED values versus treatments with a low BED. BED-effect relationships were obtained. Results: RRs for the high BED treatments were significantly lower for relapse incidence, not significantly different for disease-free survival and treatment-related mortality, and significantly higher for overall survival. BED-effect relationships indicate a decrease in relapse incidence and treatment-related mortality and an increase in disease-free and overall survival with higher BED values. Conclusion: 'More dose is better', provided that a TBI setting is used limiting the BEDs of lungs, kidneys, and eye lenses. (orig.)

  20. Total skin electron beam therapy for cutaneous T-cell lymphoma: a nationwide cohort study from Denmark

    DEFF Research Database (Denmark)

    Lindahl, Lise M; Kamstrup, Maria Rørbæk; Petersen, Peter M

    2011-01-01

    Background. Total skin electron beam therapy (TSEBT) is an effective palliative treatment for cutaneous T-cell lymphoma (CTCL). In the present study we reviewed the clinical response to TSEBT in Danish patients with CTCL. Material and methods. This retrospective study included 35 patients with CTCL...... to treatment compared to patients treated with high-dose. Consequently the study with low-dose was discontinued and published. In patients treated with high-dose the overall response rate was 100%. Complete response (CR) rate was 68% and CR occurred after a median time of 2.1 months (range 1.8 months-2.0 years...