WorldWideScience

Sample records for tongues electrode arrays

  1. Sensor Arrays and Electronic Tongue Systems

    Directory of Open Access Journals (Sweden)

    Manel del Valle

    2012-01-01

    Full Text Available This paper describes recent work performed with electronic tongue systems utilizing electrochemical sensors. The electronic tongues concept is a new trend in sensors that uses arrays of sensors together with chemometric tools to unravel the complex information generated. Initial contributions and also the most used variant employ conventional ion selective electrodes, in which it is named potentiometric electronic tongue. The second important variant is the one that employs voltammetry for its operation. As chemometric processing tool, the use of artificial neural networks as the preferred data processing variant will be described. The use of the sensor arrays inserted in flow injection or sequential injection systems will exemplify attempts made to automate the operation of electronic tongues. Significant use of biosensors, mainly enzyme-based, to form what is already named bioelectronic tongue will be also presented. Application examples will be illustrated with selected study cases from the Sensors and Biosensors Group at the Autonomous University of Barcelona.

  2. electrode array

    African Journals Online (AJOL)

    PROF EKWUEME

    A geoelectric investigation employing vertical electrical soundings (VES) using the Ajayi - Makinde Two-Electrode array and the ... arrangements used in electrical D.C. resistivity survey. These include ..... Refraction Tomography to Study the.

  3. Femtosecond laser ablation of gold interdigitated electrodes for electronic tongues

    Science.gov (United States)

    Manzoli, Alexandra; de Almeida, Gustavo F. B.; Filho, José A.; Mattoso, Luiz H. C.; Riul, Antonio; Mendonca, Cleber R.; Correa, Daniel S.

    2015-06-01

    Electronic tongue (e-tongue) sensors based on impedance spectroscopy have emerged as a potential technology to evaluate the quality and chemical composition of food, beverages, and pharmaceuticals. E-tongues usually employ transducers based on metal interdigitated electrodes (IDEs) coated with a thin layer of an active material, which is capable of interacting chemically with several types of analytes. IDEs are usually produced by photolithographic methods, which are time-consuming and costly, therefore, new fabrication technologies are required to make it more affordable. Here, we employed femtosecond laser ablation with pulse duration of 50 fs to microfabricate gold IDEs having finger width from 2.3 μm up to 3.2 μm. The parameters used in the laser ablation technique, such as light intensity, scan speed and beam spot size have been optimized to achieve uniform IDEs, which were characterized by optical and scanning electron microscopy. The electrical properties of gold IDEs fabricated by laser ablation were evaluated by impedance spectroscopy, and compared to those produced by conventional photolithography. The results show that femtosecond laser ablation is a promising alternative to conventional photolithography for fabricating metal IDEs for e-tongue systems.

  4. Coated carbon nanotube array electrodes

    Science.gov (United States)

    Ren, Zhifeng [Newton, MA; Wen, Jian [Newton, MA; Chen, Jinghua [Chestnut Hill, MA; Huang, Zhongping [Belmont, MA; Wang, Dezhi [Wellesley, MA

    2008-10-28

    The present invention provides conductive carbon nanotube (CNT) electrode materials comprising aligned CNT substrates coated with an electrically conducting polymer, and the fabrication of electrodes for use in high performance electrical energy storage devices. In particular, the present invention provides conductive CNTs electrode material whose electrical properties render them especially suitable for use in high efficiency rechargeable batteries. The present invention also provides methods for obtaining surface modified conductive CNT electrode materials comprising an array of individual linear, aligned CNTs having a uniform surface coating of an electrically conductive polymer such as polypyrrole, and their use in electrical energy storage devices.

  5. Calibration of a Sensor Array (an Electronic Tongue for Identification and Quantification of Odorants from Livestock Buildings

    Directory of Open Access Journals (Sweden)

    Jens Jørgen Lønsmann Iversen

    2007-01-01

    Full Text Available This contribution serves a dual purpose. The first purpose was to investigate the possibility of using a sensor array (an electronic tongue for on-line identification and quantification of key odorants representing a variety of chemical groups at two different acidities, pH 6 and 8. The second purpose was to simplify the electronic tongue by decreasing the number of electrodes from 14, which was the number of electrodes in the prototype. Different electrodes were used for identification and quantification of different key odorants. A total of eight electrodes were sufficient for identification and quantification in micromolar concentrations of the key odorants n-butyrate, ammonium and phenolate in test mixtures also containing iso-valerate, skatole and p-cresolate. The limited number of electrodes decreased the standard deviation and the relative standard deviation of triplicate measurements in comparison with the array comprising 14 electrodes. The electronic tongue was calibrated using 4 different test mixtures, each comprising 50 different combinations of key odorants in triplicates, a total of 600 measurements. Back propagation artificial neural network, partial least square and principal component analysis were used in the data analysis. The results indicate that the electronic tongue has a promising potential as an on- line sensor for odorants absorbed in the bioscrubber used in livestock buildings.

  6. Microneedle array electrode for human EEG recording.

    NARCIS (Netherlands)

    Lüttge, Regina; van Nieuwkasteele-Bystrova, Svetlana Nikolajevna; van Putten, Michel Johannes Antonius Maria; Vander Sloten, Jos; Verdonck, Pascal; Nyssen, Marc; Haueisen, Jens

    2009-01-01

    Microneedle array electrodes for EEG significantly reduce the mounting time, particularly by circumvention of the need for skin preparation by scrubbing. We designed a new replication process for numerous types of microneedle arrays. Here, polymer microneedle array electrodes with 64 microneedles,

  7. Virtual electrodes for high-density electrode arrays

    Science.gov (United States)

    Cela, Carlos J.; Lazzi, Gianluca

    2015-10-13

    The present embodiments are directed to implantable electrode arrays having virtual electrodes. The virtual electrodes may improve the resolution of the implantable electrode array without the burden of corresponding complexity of electronic circuitry and wiring. In a particular embodiment, a virtual electrode may include one or more passive elements to help steer current to a specific location between the active electrodes. For example, a passive element may be a metalized layer on a substrate that is adjacent to, but not directly connected to an active electrode. In certain embodiments, an active electrode may be directly coupled to a power source via a conductive connection. Beneficially, the passive elements may help to increase the overall resolution of the implantable array by providing additional stimulation points without requiring additional wiring or driver circuitry for the passive elements.

  8. Tongue motion variability with changes of upper airway stimulation electrode configuration and effects on treatment outcomes.

    Science.gov (United States)

    Steffen, Armin; Kilic, Ayse; König, Inke R; Suurna, Maria V; Hofauer, Benedikt; Heiser, Clemens

    2017-12-27

    Upper airway stimulation (UAS) is an effective treatment for obstructive sleep apnea (OSA). Previous data have demonstrated a correlation between the phenotype of tongue motion and therapy response. Closed loop hypoglossal nerve stimulation implant offers five different electrode configuration settings which may result in different tongue motion. Two-center, prospective consecutive trial in a university hospital setting. Clinical outcomes of 35 patients were analyzed after at least 12 months of device use. Tongue motion was assessed at various electrode configuration settings. Correlation between the tongue motion and treatment response was evaluated. OSA severity was significantly reduced with the use of UAS therapy (P < .001). Changes in tongue motion patterns were frequently observed (58.8%) with different electrode configuration settings. Most of the patients alternated between right and bilateral protrusion (73.5%), which are considered to be the optimal phenotypes for selective UAS responses. Different voltage settings were required to achieve functional stimulation levels when changing between the electrode settings. UAS is highly effective for OSA treatment in selected patients with an apnea-hypopnea index between 15 and 65 events per hour and higher body mass index. Attention should be given to patients with shifting tongue movement in response to change of electrode configuration. The intraoperative cuff placement should be reassessed when tongue movement shifting is observed. 4 Laryngoscope, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  9. Carbon Nanofiber Electrode Array for Neurochemical Monitoring

    Science.gov (United States)

    Koehne, Jessica E.

    2017-01-01

    A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report using vertically aligned CNF as neurotransmitter recording electrodes for application in a smart deep brain stimulation (DBS) device. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

  10. Developing barbed microtip-based electrode arrays for biopotential measurement.

    Science.gov (United States)

    Hsu, Li-Sheng; Tung, Shu-Wei; Kuo, Che-Hsi; Yang, Yao-Joe

    2014-07-10

    This study involved fabricating barbed microtip-based electrode arrays by using silicon wet etching. KOH anisotropic wet etching was employed to form a standard pyramidal microtip array and HF/HNO3 isotropic etching was used to fabricate barbs on these microtips. To improve the electrical conductance between the tip array on the front side of the wafer and the electrical contact on the back side, a through-silicon via was created during the wet etching process. The experimental results show that the forces required to detach the barbed microtip arrays from human skin, a polydimethylsiloxane (PDMS) polymer, and a polyvinylchloride (PVC) film were larger compared with those required to detach microtip arrays that lacked barbs. The impedances of the skin-electrode interface were measured and the performance levels of the proposed dry electrode were characterized. Electrode prototypes that employed the proposed tip arrays were implemented. Electroencephalogram (EEG) and electrocardiography (ECG) recordings using these electrode prototypes were also demonstrated.

  11. Design of a new electrode array for cochlear implants

    International Nuclear Information System (INIS)

    Kha, H.; Chen, B.

    2010-01-01

    Full text: This study aims to design a new electrode array which can be precisely located beneath the basilar membrane within the cochlear scala tympani. This placement of the electrode array is beneficial for increasing the effectiveness of the electrical stimulation of the audi tory nerves and maximising the growth factors delivered into the cochlea for regenerating the progressively lost auditory neurons, thereby significantly improving performance of the cochlear implant systems. Methods The design process involved two steps. First, the biocom patible nitinol-based shape memory alloy, of which mechanical deformation can be controlled using electrical cUTents/fields act vated by body temperature, was selected. Second, five different designs of the electrode array with embedded nitinol actuators were studied (Table I). The finite element method was employed to predict final positions of these electrode arrays. Results The electrode array with three 6 mm actuators at 2-8, 8-J4 and 14-20 mm from the tip (Fig. I) was found to be located most closely to the basilar membrane, compared with those in the other four cases. Conclusions A new nitinol cochlear implant electrode array with three embedded nitinol actuators has been designed. This electrode array is expected to be located beneath the basilar membrane for maximising the delivery of growth factors. Future research will involve the manufacturing of a prototype of this electrode array for use in insertion experiments and neurotrophin release tests.

  12. Activity patterns of cultured neural networks on micro electrode arrays

    NARCIS (Netherlands)

    Rutten, Wim; van Pelt, J.

    2001-01-01

    A hybrid neuro-electronic interface is a cell-cultured micro electrode array, acting as a neural information transducer for stimulation and/or recording of neural activity in the brain or the spinal cord (ventral motor region or dorsal sensory region). It consists of an array of micro electrodes on

  13. Modiolus-Hugging Intracochlear Electrode Array with Shape Memory Alloy

    Directory of Open Access Journals (Sweden)

    Kyou Sik Min

    2013-01-01

    Full Text Available In the cochlear implant system, the distance between spiral ganglia and the electrodes within the volume of the scala tympani cavity significantly affects the efficiency of the electrical stimulation in terms of the threshold current level and spatial selectivity. Because the spiral ganglia are situated inside the modiolus, the central axis of the cochlea, it is desirable that the electrode array hugs the modiolus to minimize the distance between the electrodes and the ganglia. In the present study, we propose a shape-memory-alloy-(SMA- embedded intracochlear electrode which gives a straight electrode a curved modiolus-hugging shape using the restoration force of the SMA as triggered by resistive heating after insertion into the cochlea. An eight-channel ball-type electrode array is fabricated with an embedded titanium-nickel SMA backbone wire. It is demonstrated that the electrode array changes its shape in a transparent plastic human cochlear model. To verify the safe insertion of the electrode array into the human cochlea, the contact pressures during insertion at the electrode tip and the contact pressures over the electrode length after insertion were calculated using a 3D finite element analysis. The results indicate that the SMA-embedded electrode is functionally and mechanically feasible for clinical applications.

  14. Electronic tongue - an array of non-specific chemical sensors - for analysis of radioactive solutions

    International Nuclear Information System (INIS)

    Legin, A.; Rudnitskaya, A.; Babain, V.

    2006-01-01

    Multisensor systems, combining chemical sensor arrays with multivariate data processing engines (electronic tongue) rapidly and successfully developing in the last years are capable of simultaneous quantitative analysis of several species, e.g. metals, in complex real solutions. The expansion of the metals (metal ions) and species to be detected in radioactive waste requires permanent enhancement of sensing materials and sensors, with seriously different properties from those known earlier. A prospective direction of R and D of novel sensing materials is exploitation of radiochemical extraction systems and application of extraction substances as active components of new sensors. The sensors based on bidentate phosphorous organic compounds and their combinations with chlorinated cobalt dicarbollide displayed high sensitivity and selectivity to rare-earth metal ions La 3+ , Pr 3+ , Nd 3+ , Eu 3+ . The results indicated good promise for the development of novel analytical tools for detection of multivalent metal cations in different media, particularly in corrosive solutions such as radioactive wastes and solutions derived from spent nuclear fuel. The sensors and sensor arrays made on their basis can play an important role in the development of 'electronic tongue' systems for rapid analytical determinations of different components in complex radioactive solutions

  15. The standardized EEG electrode array of the IFCN.

    Science.gov (United States)

    Seeck, Margitta; Koessler, Laurent; Bast, Thomas; Leijten, Frans; Michel, Christoph; Baumgartner, Christoph; He, Bin; Beniczky, Sándor

    2017-10-01

    Standardized EEG electrode positions are essential for both clinical applications and research. The aim of this guideline is to update and expand the unifying nomenclature and standardized positioning for EEG scalp electrodes. Electrode positions were based on 20% and 10% of standardized measurements from anatomical landmarks on the skull. However, standard recordings do not cover the anterior and basal temporal lobes, which is the most frequent source of epileptogenic activity. Here, we propose a basic array of 25 electrodes including the inferior temporal chain, which should be used for all standard clinical recordings. The nomenclature in the basic array is consistent with the 10-10-system. High-density scalp EEG arrays (64-256 electrodes) allow source imaging with even sub-lobar precision. This supplementary exam should be requested whenever necessary, e.g. search for epileptogenic activity in negative standard EEG or for presurgical evaluation. In the near future, nomenclature for high density electrodes arrays beyond the 10-10 system needs to be defined, to allow comparison and standardized recordings across centers. Contrary to the established belief that smaller heads needs less electrodes, in young children at least as many electrodes as in adults should be applied due to smaller skull thickness and the risk of spatial aliasing. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  16. A flexible capacitive tactile sensing array with floating electrodes

    International Nuclear Information System (INIS)

    Cheng, M-Y; Huang, X-H; Ma, C-W; Yang, Y-J

    2009-01-01

    In this work, we present the development of a capacitive tactile sensing array realized by using MEMS fabrication techniques and flexible printed circuit board (FPCB) technologies. The sensing array, which consists of two micromachined polydimethlysiloxane (PDMS) structures and a FPCB, will be used as the artificial skin for robot applications. Each capacitive sensing element comprises two sensing electrodes and a common floating electrode. The sensing electrodes and the metal interconnect for signal scanning are implemented on the FPCB, while the floating electrode is patterned on one of the PDMS structures. This special design can effectively reduce the complexity of the device structure and thus makes the device highly manufacturable. The characteristics of the devices with different dimensions are measured and discussed. The corresponding scanning circuits are also designed and implemented. The tactile images induced by the PMMA stamps of different shapes are also successfully captured by a fabricated 8 × 8 array

  17. Challenging aspects of contemporary cochlear implant electrode array design.

    Science.gov (United States)

    Mistrík, Pavel; Jolly, Claude; Sieber, Daniel; Hochmair, Ingeborg

    2017-12-01

    A design comparison of current perimodiolar and lateral wall electrode arrays of the cochlear implant (CI) is provided. The focus is on functional features such as acoustic frequency coverage and tonotopic mapping, battery consumption and dynamic range. A traumacity of their insertion is also evaluated. Review of up-to-date literature. Perimodiolar electrode arrays are positioned in the basal turn of the cochlea near the modiolus. They are designed to initiate the action potential in the proximity to the neural soma located in spiral ganglion. On the other hand, lateral wall electrode arrays can be inserted deeper inside the cochlea, as they are located along the lateral wall and such insertion trajectory is less traumatic. This class of arrays targets primarily surviving neural peripheral processes. Due to their larger insertion depth, lateral wall arrays can deliver lower acoustic frequencies in manner better corresponding to cochlear tonotopicity. In fact, spiral ganglion sections containing auditory nerve fibres tuned to low acoustic frequencies are located deeper than 1 and half turn inside the cochlea. For this reason, a significant frequency mismatch might be occurring for apical electrodes in perimodiolar arrays, detrimental to speech perception. Tonal languages such as Mandarin might be therefore better treated with lateral wall arrays. On the other hand, closer proximity to target tissue results in lower psychophysical threshold levels for perimodiolar arrays. However, the maximal comfort level is also lower, paradoxically resulting in narrower dynamic range than that of lateral wall arrays. Battery consumption is comparable for both types of arrays. Lateral wall arrays are less likely to cause trauma to cochlear structures. As the current trend in cochlear implantation is the maximal protection of residual acoustic hearing, the lateral wall arrays seem more suitable for hearing preservation CI surgeries. Future development could focus on combining the

  18. Developing Barbed Microtip-Based Electrode Arrays for Biopotential Measurement

    Directory of Open Access Journals (Sweden)

    Li-Sheng Hsu

    2014-07-01

    Full Text Available This study involved fabricating barbed microtip-based electrode arrays by using silicon wet etching. KOH anisotropic wet etching was employed to form a standard pyramidal microtip array and HF/HNO3 isotropic etching was used to fabricate barbs on these microtips. To improve the electrical conductance between the tip array on the front side of the wafer and the electrical contact on the back side, a through-silicon via was created during the wet etching process. The experimental results show that the forces required to detach the barbed microtip arrays from human skin, a polydimethylsiloxane (PDMS polymer, and a polyvinylchloride (PVC film were larger compared with those required to detach microtip arrays that lacked barbs. The impedances of the skin-electrode interface were measured and the performance levels of the proposed dry electrode were characterized. Electrode prototypes that employed the proposed tip arrays were implemented. Electroencephalogram (EEG and electrocardiography (ECG recordings using these electrode prototypes were also demonstrated.

  19. Built-in test of electrode degradation of multi-electrode array biosensors

    NARCIS (Netherlands)

    Liu, H.Y.; Dumas, N.; Richardson, A.; Heal, R.; Kerkhoff, Hans G.

    2006-01-01

    Micro-electrode array (MEA) is a widely used platform in biosensor systems, which provide a technology in communicating with micro chemical and biological world. This paper addresses hte topic of testing micro electrode degradation for MEAs, which is a common encountered damage during its

  20. System of fabricating a flexible electrode array

    Energy Technology Data Exchange (ETDEWEB)

    Krulevitch, Peter [Pleasanton, CA; Polla, Dennis L [Roseville, MN; Maghribi, Mariam N [Davis, CA; Hamilton, Julie [Tracy, CA; Humayun, Mark S [La Canada, CA; Weiland, James D [Valencia, CA

    2012-01-28

    An image is captured or otherwise converted into a signal in an artificial vision system. The signal is transmitted to the retina utilizing an implant. The implant consists of a polymer substrate made of a compliant material such as poly(dimethylsiloxane) or PDMS. The polymer substrate is conformable to the shape of the retina. Electrodes and conductive leads are embedded in the polymer substrate. The conductive leads and the electrodes transmit the signal representing the image to the cells in the retina. The signal representing the image stimulates cells in the retina.

  1. System of fabricating a flexible electrode array

    Science.gov (United States)

    Krulevitch, Peter; Polla, Dennis L.; Maghribi, Mariam N.; Hamilton, Julie; Humayun, Mark S.; Weiland, James D.

    2010-10-12

    An image is captured or otherwise converted into a signal in an artificial vision system. The signal is transmitted to the retina utilizing an implant. The implant consists of a polymer substrate made of a compliant material such as poly(dimethylsiloxane) or PDMS. The polymer substrate is conformable to the shape of the retina. Electrodes and conductive leads are embedded in the polymer substrate. The conductive leads and the electrodes transmit the signal representing the image to the cells in the retina. The signal representing the image stimulates cells in the retina.

  2. Density controlled carbon nanotube array electrodes

    Science.gov (United States)

    Ren, Zhifeng F [Newton, MA; Tu, Yi [Belmont, MA

    2008-12-16

    CNT materials comprising aligned carbon nanotubes (CNTs) with pre-determined site densities, catalyst substrate materials for obtaining them and methods for forming aligned CNTs with controllable densities on such catalyst substrate materials are described. The fabrication of films comprising site-density controlled vertically aligned CNT arrays of the invention with variable field emission characteristics, whereby the field emission properties of the films are controlled by independently varying the length of CNTs in the aligned array within the film or by independently varying inter-tubule spacing of the CNTs within the array (site density) are disclosed. The fabrication of microelectrode arrays (MEAs) formed utilizing the carbon nanotube material of the invention is also described.

  3. Fabrication of Pillar Shaped Electrode Arrays for Artificial Retinal Implants

    Directory of Open Access Journals (Sweden)

    Sung June Kim

    2008-09-01

    Full Text Available Polyimide has been widely applied to neural prosthetic devices, such as the retinal implants, due to its well-known biocompatibility and ability to be micropatterned. However, planar films of polyimide that are typically employed show a limited ability in reducing the distance between electrodes and targeting cell layers, which limits site resolution for effective multi-channel stimulation. In this paper, we report a newly designed device with a pillar structure that more effectively interfaces with the target. Electrode arrays were successfully fabricated and safely implanted inside the rabbit eye in suprachoroidal space. Optical Coherence Tomography (OCT showed well-preserved pillar structures of the electrode without damage. Bipolar stimulation was applied through paired sites (6:1 and the neural responses were successfully recorded from several regions in the visual cortex. Electrically evoked cortical potential by the pillar electrode array stimulation were compared to visual evoked potential under full-field light stimulation.

  4. Graphene Transparent Conductive Electrodes for Next- Generation Microshutter Arrays

    Science.gov (United States)

    Li, Mary; Sultana, Mahmooda; Hess, Larry

    2012-01-01

    Graphene is a single atomic layer of graphite. It is optically transparent and has high electron mobility, and thus has great potential to make transparent conductive electrodes. This invention contributes towards the development of graphene transparent conductive electrodes for next-generation microshutter arrays. The original design for the electrodes of the next generation of microshutters uses indium-tin-oxide (ITO) as the electrode material. ITO is widely used in NASA flight missions. The optical transparency of ITO is limited, and the material is brittle. Also, ITO has been getting more expensive in recent years. The objective of the invention is to develop a graphene transparent conductive electrode that will replace ITO. An exfoliation procedure was developed to make graphene out of graphite crystals. In addition, large areas of single-layer graphene were produced using low-pressure chemical vapor deposition (LPCVD) with high optical transparency. A special graphene transport procedure was developed for transferring graphene from copper substrates to arbitrary substrates. The concept is to grow large-size graphene sheets using the LPCVD system through chemical reaction, transfer the graphene film to a substrate, dope graphene to reduce the sheet resistance, and pattern the film to the dimension of the electrodes in the microshutter array. Graphene transparent conductive electrodes are expected to have a transparency of 97.7%. This covers the electromagnetic spectrum from UV to IR. In comparison, ITO electrodes currently used in microshutter arrays have 85% transparency in mid-IR, and suffer from dramatic transparency drop at a wavelength of near-IR or shorter. Thus, graphene also has potential application as transparent conductive electrodes for Schottky photodiodes in the UV region.

  5. Bioelectronic tongue of taste buds on microelectrode array for salt sensing.

    Science.gov (United States)

    Liu, Qingjun; Zhang, Fenni; Zhang, Diming; Hu, Ning; Wang, Hua; Hsia, K Jimmy; Wang, Ping

    2013-02-15

    Taste has received great attention for its potential applications. In this work, we combine the biological tissue with micro-chips to establish a novel bioelectronic tongue system for salt taste detection. Before experiment, we established a computational model of action potential in salt taste receptor cell, simulating the responsive results to natural salt stimuli of NaCl solution with various concentrations. Then 36-channel microelectrode arrays (MEA) with the diameter of 30 μm were fabricated on the glass substrate, and taste epithelium was stripped from rat and fixed on MEA. When stimulated by the salt stimuli, electrophysiological activities of taste receptor cells in taste buds were measured through a multi-channel recording system. Both simulation and experiment results showed a dose-dependent increase in NaCl-induced potentials of taste receptor cells, which indicated good applications in salt measurements. The multi-channel analysis demonstrated that different groups of MEA channels were activated during stimulations, indicating non-overlapping populations of receptor cells in taste buds involved in salt taste perception. The study provides an effective and reliable biosensor platform to help recognize and distinguish salt taste components. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. High-performance flexible supercapacitor based on porous array electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Shieh, Jen-Yu; Tsai, Sung-Ying; Li, Bo-Yan [Institute of Electro-Optical and Materials Science, National Formosa University, 64 Wenhua Road, Huwei, Yunlin 63208, Taiwan (China); Yu, Hsin Her, E-mail: hhyu@nfu.edu.tw [Department of Biotechnology, National Formosa University, 64 Wenhua Road, Huwei, Yunlin 63208, Taiwan (China)

    2017-07-01

    In this study, an array of polystyrene (PS) spheres was synthesized by a dispersion-polymerization technique as a template onto which a porous polydimethylsiloxane (PDMS) microarray structure was fabricated by soft lithography. A conducting layer was coated on the surface of the microarray after a suspension of multi-walled carbon nanotubes (MWCNTs) mixed with graphene (G) had been poured into the porous array. A PDMS-based porous supercapacitor was assembled by sandwiching a separator between two porous electrodes filled with a H{sub 3}PO{sub 4}/polyvinyl alcohol (PVA) gel electrolyte. The specific capacitance, electrochemical properties, and cycle stability of the porous electrode supercapacitors were explored. The porous PDMS-electrode-based supercapacitor exhibited high specific capacitance and good cycle stability, indicating its enormous potential for future applications in wearable and portable electronic products. - Highlights: • Porous electrode was prepared using an array of polystyrene spheres as template. • The porous electrodes provided increased contact area with the electrolyte. • A gel electrolyte averted problems with leakage and poor interfacial contact. • A larger separator pore size effectively reduced the internal resistance, iR{sub drop}. • Porous PDMS supercapacitor showed superior flexibility and cycling stability.

  7. A Communications Link for an Implantable Electrode Array.

    Science.gov (United States)

    1984-12-01

    be gene -rated from the 256 electrodes in a 16 x 16 array which is narrow enough in bandwidth to be transmitted over a FM radio frequency carrier. The...MARCH 1973 DESIGNED FOR HIGH-SPE ED, MEDIUM-POWER SWITCHINGU AND GENERAL PURPOSE AMPLIFIER APPLICATIONS a hFE ... Guaranteed from 100 1pA to 500 mA

  8. A Platform for Manufacturable Stretchable Micro-electrode Arrays

    NARCIS (Netherlands)

    Khoshfetrat Pakazad, S.; Savov, A.; Braam, S.R.; Dekker, R.

    2012-01-01

    A platform for the batch fabrication of pneumatically actuated Stretchable Micro-Electrode Arrays (SMEAs) by using state-of-the-art micro-fabrication techniques and materials is demonstrated. The proposed fabrication process avoids the problems normally associated with processing of thin film

  9. Additional magnetoelectric effect in electrode-arrayed magnetoelectric composite

    Directory of Open Access Journals (Sweden)

    D. A. Pan

    2014-11-01

    Full Text Available An electrode-arrayed magnetoelectric (ME composite was proposed, in which the positive and negative electrodes of the PZT-5H plate (Pb(Zr0.52Ti0.48O3 were equally divided into a 2 × 5 array, while the PZT plate remained intact. The ME voltage coefficients of these 10 sections were measured individually and in parallel/series modes. The magnetoelectric coefficient is doubled compared with un-arrayed condition, when the 10 sections are connected in parallel/series using an optimized connecting sequence derived from the charge matching rule. This scheme can also be applied to other types of layered magnetoelectric composites to obtain additional magnetoelectric effect from the original composite structure.

  10. Electrochemical DNA biosensor based on the BDD nanograss array electrode.

    Science.gov (United States)

    Jin, Huali; Wei, Min; Wang, Jinshui

    2013-04-10

    The development of DNA biosensor has attracted considerable attention due to their potential applications, including gene analysis, clinical diagnostics, forensic study and more medical applications. Using electroactive daunomycin as an indicator, the hybridization detection was measured by differential pulse voltammetry in this study. Electrochemical DNA biosensor was developed based on the BDD film electrode (fBDD) and BDD nanograss array electrode (nBDD). In comparison with fBDD and AuNPs/CA/fBDD electrode, the lower semicircle diameter of electrochemical impedance spectroscopy obtained on nBDD and AuNPs/CA/nBDD electrode indicated that the presence of nanograss array improved the reactive site, reduced the interfacial resistance, and made the electron transfer easier. Using electroactive daunomycin as an indicator, the hybridization detection was measured by differential pulse voltammetry. The experimental results demonstrated that the prepared AuNPs/CA/nBDD electrode was suitable for DNA hybridization with favorable performance of faster response, higher sensitivity, lower detection limit and satisfactory selectivity, reproducibility and stability.

  11. Formic Acid Electrooxidation by a Platinum Nanotubule Array Electrode

    Directory of Open Access Journals (Sweden)

    Eric Broaddus

    2013-01-01

    Full Text Available One-dimensional metallic nanostructures such as nanowires, rods, and tubes have drawn much attention for electrocatalytic applications due to potential advantages that include fewer diffusion impeding interfaces with polymeric binders, more facile pathways for electron transfer, and more effective exposure of active surface sites. 1D nanostructured electrodes have been fabricated using a variety of methods, typically showing improved current response which has been attributed to improved CO tolerance, enhanced surface activity, and/or improved transport characteristics. A template wetting approach was used to fabricate an array of platinum nanotubules which were examined electrochemically with regard to the electrooxidation of formic acid. Arrays of 100 and 200 nm nanotubules were compared to a traditional platinum black catalyst, all of which were found to have similar surface areas. Peak formic acid oxidation current was observed to be highest for the 100 nm nanotubule array, followed by the 200 nm array and the Pt black; however, CO tolerance of all electrodes was similar, as were the onset potentials of the oxidation and reduction peaks. The higher current response was attributed to enhanced mass transfer in the nanotubule electrodes, likely due to a combination of both the more open nanostructure as well as the lack of a polymeric binder in the catalyst layer.

  12. The rational for a mid-scala electrode array.

    Science.gov (United States)

    Boyle, P J

    2016-06-01

    Today increasing numbers of cochlear implant candidates have residual hearing that can be aided and hence is worth trying to preserve. This means that surgical technique and electrode array design must be adapted to minimize trauma. Wide opening of the round window is often preferred to reduce drill related trauma and to avoid pressure spikes during electrode array insertion. A recent meta-analysis suggested that there is no significant correlation between hearing preservation and either insertion depth or scala position. However, a slow insertion speed of at least 30seconds was associated with better hearing preservation. An electrode design is proposed that targets the middle of the scala tympani. This minimizes frictional forces from either lateral or medial wall during insertion and imposes less static pressure on cochlear structures following insertion. The flexibility to insert via the round window requires a 0.7-mm maximum dimension at the proximal end of the array. Micro-anatomical analysis by micro-CT indicated that a 420-degree insertion depth was optimal between cochlear coverage and available space within the scala tympani. Physical measurements showed that mean insertion forces remained below 10mN during insertion. A series of 20 human temporal bone insertions found a mean insertion depth of 400 degrees with no scala dislocations. Six clinical series, in total 94 cases, found postoperative hearing in 81% of cases with a mean loss of 12dB compared to preoperative levels. Speech understanding out to one year post-fitting trended better for a mid-scala design group than for a straight electrode array group; although the differences were not statistically significant. A mid-scala array design appears able to be inserted with minimal trauma, to return a predictable insertion depth across various sizes of cochleae and to support reasonable levels of speech understanding without relying on residual hearing. Copyright © 2016. Published by Elsevier Masson

  13. Array of 1- to 2-GHz electrodes for stochastic cooling

    International Nuclear Information System (INIS)

    Voelker, F.; Henderson, T.; Johnson, J.

    1983-03-01

    Described is an array of directional-coupler loop pairs that are to be used as either pickup or kicker electrodes for the frequency range of 1 to 2 GHz. Each coupler pair is a lambda/4 long parallel-plane transmission line that is arranged to be flush with the upper and lower surfaces of a rectangular beam pipe. As pickups, the coupler pairs are used in arrays and are operated at 80 degrees Kelvin for improving the signal-to-noise ratio. The loop output power is added in stripline combiner networks before being fed to a low-noise preamplifier. When the couplers are used as kickers, the combining network serves to split power and distribute it uniformly to each electrode

  14. Micromachined three-dimensional electrode arrays for transcutaneous nerve tracking

    Science.gov (United States)

    Rajaraman, Swaminathan; Bragg, Julian A.; Ross, James D.; Allen, Mark G.

    2011-08-01

    We report the development of metal transfer micromolded (MTM) three-dimensional microelectrode arrays (3D MEAs) for a transcutaneous nerve tracking application. The measurements of electrode-skin-electrode impedance (ESEI), electromyography (EMG) and nerve conduction utilizing these minimally invasive 3D MEAs are demonstrated in this paper. The 3D MEAs used in these measurements consist of a metalized micro-tower array that can penetrate the outer layers of the skin in a painless fashion and are fabricated using MTM technology. Two techniques, an inclined UV lithography approach and a double-side exposure of thick negative tone resist, have been developed to fabricate the 3D MEA master structure. The MEAs themselves are fabricated from the master structure utilizing micromolding techniques. Metal patterns are transferred during the micromolding process, thereby ensuring reduced process steps compared to traditional silicon-based approaches. These 3D MEAs have been packaged utilizing biocompatible Kapton® substrates. ESEI measurements have been carried out on test human subjects with standard commercial wet electrodes as a reference. The 3D MEAs demonstrate an order of magnitude lower ESEI (normalized to area) compared to wet electrodes for an area that is 12.56 times smaller. This compares well with other demonstrated approaches in literature. For a nerve tracking demonstration, we have chosen EMG and nerve conduction measurements on test human subjects. The 3D MEAs show 100% improvement in signal power and SNR/√area as compared to standard electrodes. They also demonstrate larger amplitude signals and faster rise times during nerve conduction measurements. We believe that this microfabrication and packaging approach scales well to large-area, high-density arrays required for applications like nerve tracking. This development will increase the stimulation and recording fidelity of skin surface electrodes, while increasing their spatial resolution by an order of

  15. Tongue problems

    Science.gov (United States)

    ... for mouth ulcers, leukoplakia, oral cancer, and other mouth sores. Anti-inflammatory medicines may be prescribed for glossititis and geographic tongue. Alternative Names Dark tongue; Burning tongue syndrome - symptoms Images Black hairy tongue Black hairy tongue ...

  16. Micromachined three-dimensional electrode arrays for transcutaneous nerve tracking

    International Nuclear Information System (INIS)

    Rajaraman, Swaminathan; Allen, Mark G; Bragg, Julian A; Ross, James D

    2011-01-01

    We report the development of metal transfer micromolded (MTM) three-dimensional microelectrode arrays (3D MEAs) for a transcutaneous nerve tracking application. The measurements of electrode–skin–electrode impedance (ESEI), electromyography (EMG) and nerve conduction utilizing these minimally invasive 3D MEAs are demonstrated in this paper. The 3D MEAs used in these measurements consist of a metalized micro-tower array that can penetrate the outer layers of the skin in a painless fashion and are fabricated using MTM technology. Two techniques, an inclined UV lithography approach and a double-side exposure of thick negative tone resist, have been developed to fabricate the 3D MEA master structure. The MEAs themselves are fabricated from the master structure utilizing micromolding techniques. Metal patterns are transferred during the micromolding process, thereby ensuring reduced process steps compared to traditional silicon-based approaches. These 3D MEAs have been packaged utilizing biocompatible Kapton® substrates. ESEI measurements have been carried out on test human subjects with standard commercial wet electrodes as a reference. The 3D MEAs demonstrate an order of magnitude lower ESEI (normalized to area) compared to wet electrodes for an area that is 12.56 times smaller. This compares well with other demonstrated approaches in literature. For a nerve tracking demonstration, we have chosen EMG and nerve conduction measurements on test human subjects. The 3D MEAs show 100% improvement in signal power and SNR/√area as compared to standard electrodes. They also demonstrate larger amplitude signals and faster rise times during nerve conduction measurements. We believe that this microfabrication and packaging approach scales well to large-area, high-density arrays required for applications like nerve tracking. This development will increase the stimulation and recording fidelity of skin surface electrodes, while increasing their spatial resolution by an order

  17. Conformally encapsulated multi-electrode arrays with seamless insulation

    Energy Technology Data Exchange (ETDEWEB)

    Tabada, Phillipe J.; Shah, Kedar G.; Tolosa, Vanessa; Pannu, Satinderall S.; Tooker, Angela; Delima, Terri; Sheth, Heeral; Felix, Sarah

    2016-11-22

    Thin-film multi-electrode arrays (MEA) having one or more electrically conductive beams conformally encapsulated in a seamless block of electrically insulating material, and methods of fabricating such MEAs using reproducible, microfabrication processes. One or more electrically conductive traces are formed on scaffold material that is subsequently removed to suspend the traces over a substrate by support portions of the trace beam in contact with the substrate. By encapsulating the suspended traces, either individually or together, with a single continuous layer of an electrically insulating material, a seamless block of electrically insulating material is formed that conforms to the shape of the trace beam structure, including any trace backings which provide suspension support. Electrical contacts, electrodes, or leads of the traces are exposed from the encapsulated trace beam structure by removing the substrate.

  18. A multichannel scala tympani electrode array incorporating a drug delivery system for chronic intracochlear infusion.

    Science.gov (United States)

    Shepherd, Robert K; Xu, Jin

    2002-10-01

    We have developed a novel scala tympani electrode array suitable for use in experimental animals. A unique feature of this array is its ability to chronically deliver pharmacological agents to the scala tympani. The design of the electrode array is described in detail. Experimental studies performed in guinea pigs confirm that this array can successfully deliver various drugs to the cochlea while chronically stimulating the auditory nerve.

  19. Solution-based analysis of multiple analytes by a sensor array: toward the development of an electronic tongue

    Science.gov (United States)

    Savoy, Steven M.; Lavigne, John J.; Yoo, J. S.; Wright, John; Rodriguez, Marc; Goodey, Adrian; McDoniel, Bridget; McDevitt, John T.; Anslyn, Eric V.; Shear, Jason B.; Ellington, Andrew D.; Neikirk, Dean P.

    1998-12-01

    A micromachined sensor array has been developed for the rapid characterization of multi-component mixtures in aqueous media. The sensor functions in a manner analogous to that of the mammalian tongue, using an array composed of individually immobilized polystyrene-polyethylene glycol composite microspheres selectively arranged in micromachined etch cavities localized o n silicon wafers. Sensing occurs via colorimetric or fluorometric changes to indicator molecules that are covalently bound to amine termination sites on the polymeric microspheres. The hybrid micromachined structure has been interfaced directly to a charged-coupled-device that is used for the simultaneous acquisition of the optical data from the individually addressable `taste bud' elements. With the miniature sensor array, acquisition of data streams composed of red, green, and blue color patterns distinctive for the analytes in the solution are rapidly acquired. The unique combination of carefully chosen reporter molecules with water permeable microspheres allows for the simultaneous detection and quantification of a variety of analytes. The fabrication of the sensor structures and the initial colorimetric and fluorescent responses for pH, Ca+2, Ce+3, and sugar are reported. Interface to microfluidic components should also be possible, producing a complete sampling/sensing system.

  20. Mapping the temporal pole with a specialized electrode array: technique and preliminary results

    International Nuclear Information System (INIS)

    Abel, Taylor J; Rhone, Ariane E; Nourski, Kirill V; Oya, Hiroyuki; Kawasaki, Hiroto; Howard, Matthew A III; Granner, Mark A; Tranel, Daniel T; Griffiths, Timothy D

    2014-01-01

    Temporopolar cortex plays a crucial role in the pathogenesis of temporal lobe epilepsy and subserves important cognitive functions. Because of its shape and position in the middle cranial fossa, complete electrode coverage of the temporal pole (TP) is difficult to achieve using existing devices. We designed a novel TP electrode array that conforms to the surface of temporopolar cortex and achieves dense electrode coverage of this important brain region. A multi-pronged electrode array was designed that can be placed over the surface of the TP using a straightforward insertion technique. Twelve patients with medically intractable epilepsy were implanted with the TP electrode array for purposes of seizure localization. Select patients underwent cognitive mapping by electrocorticographic (ECoG) recording from the TP during a naming task. Use of the array resulted in excellent TP electrode coverage in all patients. High quality ECoG data were consistently obtained for purposes of delineating seizure activity and functional mapping. During a naming task, significant increases in ECoG power were observed within localized subregions of the TP. One patient developed a transient neurological deficit thought to be related to the mass effect of multiple intracranial recording arrays, including the TP array. This deficit resolved following removal of all electrodes. The TP electrode array overcomes limitations of existing devices and enables clinicians and researchers to obtain optimal multi-site recordings from this important brain region. (paper)

  1. Amperometric Bioelectronic Tongue for glucose determination

    Directory of Open Access Journals (Sweden)

    Yazan Al-Issa

    2015-03-01

    Full Text Available An amperometric Bioelectronic Tongue is reported for glucose determination that contains eight sensor electrodes constructed using different metal electrodes (Pt, Au, oxidoreductase enzymes (glucose oxidase, ascorbate oxidase, uricase, and membrane coatings (Nafion, chitosan. The response to varying concentrations of glucose, ascorbic acid, uric acid, and acetaminophen was tested for two models, concentration determination by current density measurements at individual electrodes and concentration determination by a linear regression model for the entire electrode array. The reduced chi-squared for the full array model was found to be about one order of magnitude lower than that for the individual-electrode model. Discrimination of glucose from chemical interference by the other three species is accomplished through a combination of enzyme catalysis, metal electrocatalysis, and membrane surface charge. The benefit of incorporating enzyme electrodes into the sensor array is illustrated by the lower correlation coefficients between different enzyme electrodes relative to non-enzyme coated electrodes. This approach can be more generally applied to detection of other substrates of oxidoreductase enzymes.

  2. Improved 2-D resistivity imaging of features in covered karst terrain with arrays of implanted electrodes

    Science.gov (United States)

    Kiflu, H. G.; Kruse, S. E.; Harro, D.; Loke, M. H.; Wilkinson, P. B.

    2013-12-01

    Electrical resistivity tomography is commonly used to identify geologic features associated with sinkhole formation. In covered karst terrain, however, it can be difficult to resolve the depth to top of limestone with this method. This is due to the fact that array lengths, and hence depth of resolution, are often limited by residential or commercial lot dimensions in urban environments. Furthermore, the sediments mantling the limestone are often clay-rich and highly conductive. The resistivity method has limited sensitivity to resistive zones beneath conductive zones. This sensitivity can be improved significantly with electrodes implanted at depth in the cover sediments near the top of limestone. An array of deep electrodes is installed with direct push technology in the karst cover. When combined with a surface array in which each surface electrode is underlain by a deep electrode, the array geometry is similar to a borehole array turned on its side. This method, called the Multi-Electrode Resistivity Implant Technique (MERIT), offers the promise of significantly improved resolution of epikarst and cover collapse development zones in the overlying sediment, the limestone or at the sediment-bedrock interface in heterogeneous karst environments. With a non-traditional array design, the question of optimal array geometries arises. Optimizing array geometries is complicated by the fact that many plausible 4-electrode readings will produce negative apparent resistivity values, even in homogeneous terrain. Negative apparent resistivities cannot be used in inversions based on the logarithm of the apparent resistivity. New algorithms for seeking optimal array geometries have been developed by modifying the 'Compare R' method of Wilkinson and Loke. The optimized arrays show significantly improved resolution over basic arrays adapted from traditional 2D surface geometries. Several MERIT case study surveys have been conducted in covered karst in west-central Florida, with

  3. A Palladium-Tin Modified Microband Electrode Array for Nitrate Determination

    Directory of Open Access Journals (Sweden)

    Yexiang Fu

    2015-09-01

    Full Text Available A microband electrode array modified with palladium-tin bimetallic composite has been developed for nitrate determination. The microband electrode array was fabricated by Micro Electro-Mechanical System (MEMS technique. Palladium and tin were electrodeposited successively on the electrode, forming a double-layer structure. The effect of the Pd-Sn composite was investigated and its enhancement of catalytic activity and lifetime was revealed. The Pd-Sn modified electrode showed good linearity (R2 = 0.998 from 1 mg/L to 20 mg/L for nitrate determination with a sensitivity of 398 μA/(mg∙L−1∙cm2. The electrode exhibited a satisfying analytical performance after 60 days of storage, indicating a long lifetime. Good repeatability was also displayed by the Pd-Sn modified electrodes. The results provided an option for nitrate determination in water.

  4. A strategy for selective detection based on interferent depleting and redox cycling using the plane-recessed microdisk array electrodes

    International Nuclear Information System (INIS)

    Zhu Feng; Yan Jiawei; Lu Miao; Zhou Yongliang; Yang Yang; Mao Bingwei

    2011-01-01

    Highlights: → A novel strategy based on a combination of interferent depleting and redox cycling is proposed for the plane-recessed microdisk array electrodes. → The strategy break up the restriction of selectively detecting a species that exhibits reversible reaction in a mixture with one that exhibits an irreversible reaction. → The electrodes enhance the current signal by redox cycling. → The electrodes can work regardless of the reversibility of interfering species. - Abstract: The fabrication, characterization and application of the plane-recessed microdisk array electrodes for selective detection are demonstrated. The electrodes, fabricated by lithographic microfabrication technology, are composed of a planar film electrode and a 32 x 32 recessed microdisk array electrode. Different from commonly used redox cycling operating mode for array configurations such as interdigitated array electrodes, a novel strategy based on a combination of interferent depleting and redox cycling is proposed for the electrodes with an appropriate configuration. The planar film electrode (the plane electrode) is used to deplete the interferent in the diffusion layer. The recessed microdisk array electrode (the microdisk array), locating within the diffusion layer of the plane electrode, works for detecting the target analyte in the interferent-depleted diffusion layer. In addition, the microdisk array overcomes the disadvantage of low current signal for a single microelectrode. Moreover, the current signal of the target analyte that undergoes reversible electron transfer can be enhanced due to the redox cycling between the plane electrode and the microdisk array. Based on the above working principle, the plane-recessed microdisk array electrodes break up the restriction of selectively detecting a species that exhibits reversible reaction in a mixture with one that exhibits an irreversible reaction, which is a limitation of single redox cycling operating mode. The

  5. Investigation of Implantable Multi-Channel Electrode Array in Rat Cerebral Cortex Used for Recording

    Science.gov (United States)

    Taniguchi, Noriyuki; Fukayama, Osamu; Suzuki, Takafumi; Mabuchi, Kunihiko

    There have recently been many studies concerning the control of robot movements using neural signals recorded from the brain (usually called the Brain-Machine interface (BMI)). We fabricated implantable multi-electrode arrays to obtain neural signals from the rat cerebral cortex. As any multi-electrode array should have electrode alignment that minimizes invasion, it is necessary to customize the recording site. We designed three types of 22-channel multi-electrode arrays, i.e., 1) wide, 2) three-layered, and 3) separate. The first extensively covers the cerebral cortex. The second has a length of 2 mm, which can cover the area of the primary motor cortex. The third array has a separate structure, which corresponds to the position of the forelimb and hindlimb areas of the primary motor cortex. These arrays were implanted into the cerebral cortex of a rat. We estimated the walking speed from neural signals using our fabricated three-layered array to investigate its feasibility for BMI research. The neural signal of the rat and its walking speed were simultaneously recorded. The results revealed that evaluation using either the anterior electrode group or posterior group provided accurate estimates. However, two electrode groups around the center yielded poor estimates although it was possible to record neural signals.

  6. Ti/TiO 2 nanotube array electrode as a new sensor to ...

    Indian Academy of Sciences (India)

    The Ti/TiO2 nanotube array (Ti-NTA) electrode was prepared by anodizing of the Ti foil ... and the pH=3.0 and =1.0 V (vs. reference electrode) were determined as the ... It was found that the photocurrent of EG was linearly dependent on the ...

  7. Cochlear pathology following reimplantation of a multichannel scala tympani electrode array in the macaque.

    Science.gov (United States)

    Shepherd, R K; Clark, G M; Xu, S A; Pyman, B C

    1995-03-01

    The histopathologic consequence of removing and reimplanting intracochlear electrode arrays on residual auditory nerve fibers is an important issue when evaluating the safety of cochlear prostheses. The authors have examined this issue by implanting multichannel intracochlear electrodes in macaque monkeys. Macaques were selected because of the similarity of the surgical technique used to insert electrodes into the cochlea compared to that in humans, in particular the ability to insert the arrays into the upper basal turn. Five macaques were bilaterally implanted with the Melbourne/Cochlear banded electrode array. Following a minimum implant period of 5 months, the electrode array on one side of each animal was removed and another immediately implanted. The animals were sacrificed a minimum of 5 months following the reinsertion procedure, and the cochleas prepared for histopathologic analysis. Long-term implantation of the electrode resulted in a relatively mild tissue response within the cochlea. Results also showed that inner and outer hair cell survival, although significantly reduced adjacent to the array, was normal in 8 of the 10 cochleas apicalward. Moreover, the electrode reinsertion procedure did not appear to adversely affect this apical hair cell population. Significant new bone formation was frequently observed in both control and reimplanted cochleas close to the electrode fenestration site and was associated with trauma to the endosteum and/or the introduction of bone chips into the cochlea at the time of surgery. Electrode insertion trauma, involving the osseous spiral lamina or basilar membrane, was more commonly observed in reimplanted cochleas. This damage was usually restricted to the lower basal turn and resulted in a more extensive ganglion cell loss. Finally, in a number of cochleas part of the electrode array was located within the scala media or scala vestibuli. These electrodes did not appear to evoke a more extensive tissue response or

  8. Fusion of Potentiometric & Voltammetric Electronic Tongue for Classification of Black Tea Taste based on Theaflavins (TF) Content

    Science.gov (United States)

    Bhattacharyya, Nabarun; Legin, Andrey; Papieva, Irina; Sarkar, Subrata; Kirsanov, Dmitry; Kartsova, Anna; Ghosh, Arunangshu; Bandyopadhyay, Rajib

    2011-09-01

    Black tea is an extensively consumed beverage worldwide with an expanding market. The final quality of black tea depends upon number of chemical compounds present in the tea. Out of these compounds, theaflavins (TF), which is responsible for astringency in black tea, plays an important role in determining the final taste of the finished black tea. The present paper reports our effort to correlate the theaflavins contents with the voltammetric and potentiometric electronic tongue (e-tongue) data. Noble metal-based electrode array has been used for collecting data though voltammetric electronic tongue where as liquid filled membrane based electrodes have been used for potentiometric electronic tongue. Black tea samples with tea taster score and biochemical results have been collected from Tea Research Association, Tocklai, India for the analysis purpose. In this paper, voltammetric and potentiometric e-tongue responses are combined to demonstrate improvement of cluster formation among tea samples with different ranges of TF values.

  9. Fabrication of combinatorial nm-planar electrode array for high throughput evaluation of organic semiconductors

    International Nuclear Information System (INIS)

    Haemori, M.; Edura, T.; Tsutsui, K.; Itaka, K.; Wada, Y.; Koinuma, H.

    2006-01-01

    We have fabricated a combinatorial nm-planar electrode array by using photolithography and chemical mechanical polishing processes for high throughput electrical evaluation of organic devices. Sub-nm precision was achieved with respect to the average level difference between each pair of electrodes and a dielectric layer. The insulating property between the electrodes is high enough to measure I-V characteristics of organic semiconductors. Bottom-contact field-effect-transistors (FETs) of pentacene were fabricated on this electrode array by use of molecular beam epitaxy. It was demonstrated that the array could be used as a pre-patterned device substrate for high throughput screening of the electrical properties of organic semiconductors

  10. The new mid-scala electrode array: a radiologic and histologic study in human temporal bones.

    Science.gov (United States)

    Hassepass, Frederike; Bulla, Stefan; Maier, Wolfgang; Laszig, Roland; Arndt, Susan; Beck, Rainer; Traser, Lousia; Aschendorff, Antje

    2014-09-01

    To analyze the quality of insertion of the newly developed midscala (MS) electrode, which targets a midscalar electrode position to reduce the risk of trauma to the lateral wall and the modiolus. Modern cochlear implant surgery aims for a safe intracochlear placement of electrode arrays with an ongoing debate regarding cochleostomy or round window (RW) insertion and the use of lateral wall or perimodiolar electrode placement. Intracochlear trauma after insertion of different electrodes depends on insertion mode and electrode design and may result in trauma to the delicate structures of the cochlear. We performed a temporal bone (TB) trial with insertion of the MS electrode in n = 20 TB's after a mastoidectomy and posterior tympanotomy. Insertion was performed either via the RW or a cochleostomy. Electrode positioning, length of insertion, and angle of insertion were analyzed with rotational tomography (RT). TBs were histologically analyzed. Results of RT and histology were compared. Scala tympani (ST) insertion could be accomplished reliably by both RW and via a cochleostomy approach. In 20 TBs, 1 scala vestibuli insertion, 1 incomplete (ST), and 1 elevation of basilar membrane were depicted. No trauma was found in 94.7% of all ST insertions. RT allowed determination of the intracochlear electrode position, which was specified by histologic sectioning. The new MS electrode seems to fulfill reliable atraumatic intracochlear placement via RW and cochleostomy approaches. RT is available for evaluation of intracochlear electrode position, serving as a potential quality control instrument in human implantation.

  11. Rapid prototyping of flexible intrafascicular electrode arrays by picosecond laser structuring.

    Science.gov (United States)

    Mueller, Matthias; de la Oliva, Natalia; Del Valle, Jaume; Delgado-Martínez, Ignacio; Navarro, Xavier; Stieglitz, Thomas

    2017-12-01

    Interfacing the peripheral nervous system can be performed with a large variety of electrode arrays. However, stimulating and recording a nerve while having a reasonable amount of channels limits the number of available systems. Translational research towards human clinical trial requires device safety and biocompatibility but would benefit from design flexibility in the development process to individualize probes. We selected established medical grade implant materials like precious metals and Parylene C to develop a rapid prototyping process for novel intrafascicular electrode arrays using a picosecond laser structuring. A design for a rodent animal model was developed in conjunction with an intrafascicular implantation strategy. Electrode characterization and optimization was performed first in saline solution in vitro before performance and biocompatibility were validated in sciatic nerves of rats in chronic implantation. The novel fabrication process proved to be suitable for prototyping and building intrafascicular electrode arrays. Electrochemical properties of the electrode sites were enhanced and tested for long-term stability. Chronic implantation in the sciatic nerve of rats showed good biocompatibility, selectivity and stable stimulation thresholds. Established medical grade materials can be used for intrafascicular nerve electrode arrays when laser structuring defines structure size in the micro-scale. Design flexibility reduces re-design cycle time and material certificates are beneficial support for safety studies on the way to clinical trials.

  12. Phosphorization boosts the capacitance of mixed metal nanosheet arrays for high performance supercapacitor electrodes.

    Science.gov (United States)

    Lan, Yingying; Zhao, Hongyang; Zong, Yan; Li, Xinghua; Sun, Yong; Feng, Juan; Wang, Yan; Zheng, Xinliang; Du, Yaping

    2018-05-01

    Binary transition metal phosphides hold immense potential as innovative electrode materials for constructing high-performance energy storage devices. Herein, porous binary nickel-cobalt phosphide (NiCoP) nanosheet arrays anchored on nickel foam (NF) were rationally designed as self-supported binder-free electrodes with high supercapacitance performance. Taking the combined advantages of compositional features and array architectures, the nickel foam supported NiCoP nanosheet array (NiCoP@NF) electrode possesses superior electrochemical performance in comparison with Ni-Co LDH@NF and NiCoO2@NF electrodes. The NiCoP@NF electrode shows an ultrahigh specific capacitance of 2143 F g-1 at 1 A g-1 and retained 1615 F g-1 even at 20 A g-1, showing excellent rate performance. Furthermore, a binder-free all-solid-state asymmetric supercapacitor device is designed, which exhibits a high energy density of 27 W h kg-1 at a power density of 647 W kg-1. The hierarchical binary nickel-cobalt phosphide nanosheet arrays hold great promise as advanced electrode materials for supercapacitors with high electrochemical performance.

  13. Simulating pad-electrodes with high-definition arrays in transcranial electric stimulation

    Science.gov (United States)

    Kempe, René; Huang, Yu; Parra, Lucas C.

    2014-04-01

    Objective. Research studies on transcranial electric stimulation, including direct current, often use a computational model to provide guidance on the placing of sponge-electrode pads. However, the expertise and computational resources needed for finite element modeling (FEM) make modeling impractical in a clinical setting. Our objective is to make the exploration of different electrode configurations accessible to practitioners. We provide an efficient tool to estimate current distributions for arbitrary pad configurations while obviating the need for complex simulation software. Approach. To efficiently estimate current distributions for arbitrary pad configurations we propose to simulate pads with an array of high-definition (HD) electrodes and use an efficient linear superposition to then quickly evaluate different electrode configurations. Main results. Numerical results on ten different pad configurations on a normal individual show that electric field intensity simulated with the sampled array deviates from the solutions with pads by only 5% and the locations of peak magnitude fields have a 94% overlap when using a dense array of 336 electrodes. Significance. Computationally intensive FEM modeling of the HD array needs to be performed only once, perhaps on a set of standard heads that can be made available to multiple users. The present results confirm that by using these models one can now quickly and accurately explore and select pad-electrode montages to match a particular clinical need.

  14. Rapid prototyping of flexible intrafascicular electrode arrays by picosecond laser structuring

    Science.gov (United States)

    Mueller, Matthias; de la Oliva, Natalia; del Valle, Jaume; Delgado-Martínez, Ignacio; Navarro, Xavier; Stieglitz, Thomas

    2017-12-01

    Objective. Interfacing the peripheral nervous system can be performed with a large variety of electrode arrays. However, stimulating and recording a nerve while having a reasonable amount of channels limits the number of available systems. Translational research towards human clinical trial requires device safety and biocompatibility but would benefit from design flexibility in the development process to individualize probes. Approach. We selected established medical grade implant materials like precious metals and Parylene C to develop a rapid prototyping process for novel intrafascicular electrode arrays using a picosecond laser structuring. A design for a rodent animal model was developed in conjunction with an intrafascicular implantation strategy. Electrode characterization and optimization was performed first in saline solution in vitro before performance and biocompatibility were validated in sciatic nerves of rats in chronic implantation. Main results. The novel fabrication process proved to be suitable for prototyping and building intrafascicular electrode arrays. Electrochemical properties of the electrode sites were enhanced and tested for long-term stability. Chronic implantation in the sciatic nerve of rats showed good biocompatibility, selectivity and stable stimulation thresholds. Significance. Established medical grade materials can be used for intrafascicular nerve electrode arrays when laser structuring defines structure size in the micro-scale. Design flexibility reduces re-design cycle time and material certificates are beneficial support for safety studies on the way to clinical trials.

  15. Stretchable Transparent Electrode Arrays for Simultaneous Electrical and Optical Interrogation of Neural Circuits in Vivo.

    Science.gov (United States)

    Zhang, Jing; Liu, Xiaojun; Xu, Wenjing; Luo, Wenhan; Li, Ming; Chu, Fangbing; Xu, Lu; Cao, Anyuan; Guan, Jisong; Tang, Shiming; Duan, Xiaojie

    2018-04-09

    Recent developments of transparent electrode arrays provide a unique capability for simultaneous optical and electrical interrogation of neural circuits in the brain. However, none of these electrode arrays possess the stretchability highly desired for interfacing with mechanically active neural systems, such as the brain under injury, the spinal cord, and the peripheral nervous system (PNS). Here, we report a stretchable transparent electrode array from carbon nanotube (CNT) web-like thin films that retains excellent electrochemical performance and broad-band optical transparency under stretching and is highly durable under cyclic stretching deformation. We show that the CNT electrodes record well-defined neuronal response signals with negligible light-induced artifacts from cortical surfaces under optogenetic stimulation. Simultaneous two-photon calcium imaging through the transparent CNT electrodes from cortical surfaces of GCaMP-expressing mice with epilepsy shows individual activated neurons in brain regions from which the concurrent electrical recording is taken, thus providing complementary cellular information in addition to the high-temporal-resolution electrical recording. Notably, the studies on rats show that the CNT electrodes remain operational during and after brain contusion that involves the rapid deformation of both the electrode array and brain tissue. This enables real-time, continuous electrophysiological monitoring of cortical activity under traumatic brain injury. These results highlight the potential application of the stretchable transparent CNT electrode arrays in combining electrical and optical modalities to study neural circuits, especially under mechanically active conditions, which could potentially provide important new insights into the local circuit dynamics of the spinal cord and PNS as well as the mechanism underlying traumatic injuries of the nervous system.

  16. Tongue Disorders

    Science.gov (United States)

    ... of many muscles. The upper surface contains your taste buds. Problems with the tongue include Pain Swelling Changes in color or texture Abnormal movement or difficulty moving the tongue Taste problems These problems can have many different causes. ...

  17. Servo scanning 3D micro EDM for array micro cavities using on-machine fabricated tool electrodes

    Science.gov (United States)

    Tong, Hao; Li, Yong; Zhang, Long

    2018-02-01

    Array micro cavities are useful in many fields including in micro molds, optical devices, biochips and so on. Array servo scanning micro electro discharge machining (EDM), using array micro electrodes with simple cross-sectional shape, has the advantage of machining complex 3D micro cavities in batches. In this paper, the machining errors caused by offline-fabricated array micro electrodes are analyzed in particular, and then a machining process of array servo scanning micro EDM is proposed by using on-machine fabricated array micro electrodes. The array micro electrodes are fabricated on-machine by combined procedures including wire electro discharge grinding, array reverse copying and electrode end trimming. Nine-array tool electrodes with Φ80 µm diameter and 600 µm length are obtained. Furthermore, the proposed process is verified by several machining experiments for achieving nine-array hexagonal micro cavities with top side length of 300 µm, bottom side length of 150 µm, and depth of 112 µm or 120 µm. In the experiments, a chip hump accumulates on the electrode tips like the built-up edge in mechanical machining under the conditions of brass workpieces, copper electrodes and the dielectric of deionized water. The accumulated hump can be avoided by replacing the water dielectric by an oil dielectric.

  18. Orthogonal electrode catheter array for mapping of endocardial focal site of ventricular activation

    Energy Technology Data Exchange (ETDEWEB)

    Desai, J.M.; Nyo, H.; Vera, Z.; Seibert, J.A.; Vogelsang, P.J. (Division of Cardiovascular Medicine, University of California, School of Medicine, Davis (USA))

    1991-04-01

    Precise location of the endocardial site of origin of ventricular tachycardia may facilitate surgical and catheter ablation of this arrhythmia. The endocardial catheter mapping technique can locate the site of ventricular tachycardia within 4-8 cm2 of the earliest site recorded by the catheter. This report describes an orthogonal electrode catheter array (OECA) for mapping and radiofrequency ablation (RFA) of endocardial focal site of origin of a plunge electrode paced model of ventricular activation in dogs. The OECA is an 8 F five pole catheter with four peripheral electrodes and one central electrode (total surface area 0.8 cm{sup 2}). In eight mongrel dogs, mapping was performed by arbitrarily dividing the left ventricle (LV) into four segments. Each segment was mapped with OECA to find the earliest segment. Bipolar and unipolar electrograms were obtained. The plunge electrode (not visible on fluoroscopy) site was identified by the earliest wave front arrival times of -30 msec or earlier at two or more electrodes (unipolar electrograms) with reference to the earliest recorded surface ECG (I, AVF, and V1). Validation of the proximity of the five electrodes of the OECA to the plunge electrode was performed by digital radiography and RFA. Pathological examination was performed to document the proximity of the OECA to the plunge electrode and also for the width, depth, and microscopic changes of the ablation. To find the segment with the earliest LV activation a total of 10 {plus minus} 3 (mean {plus minus} SD) positions were mapped. Mean arrival times at the two earlier electrodes were -39 {plus minus} 4 msec and -35 {plus minus} 3 msec. Digital radiography showed the plunge electrode to be within the area covered by all five electrodes in all eight dogs. The plunge electrode was within 1 cm2 area of the region of RFA in all eight dogs.

  19. Fabrication and electrical properties of single wall carbon nanotube channel and graphene electrode based transistors arrays

    Energy Technology Data Exchange (ETDEWEB)

    Seo, M.; Kim, H.; Kim, Y. H.; Yun, H.; McAllister, K.; Lee, S. W., E-mail: leesw@konkuk.ac.kr [Division of Quantum Phases and Devices, School of Physics, Konkuk University, Seoul 143-701 (Korea, Republic of); Na, J.; Kim, G. T. [School of Electrical Engineering, Korea University, Seoul 136-701 (Korea, Republic of); Lee, B. J.; Kim, J. J.; Jeong, G. H. [Department of Nano Applied Engineering, Kangwon National University, Kangwon-do 200-701 (Korea, Republic of); Lee, I.; Kim, K. S. [Department of Physics and Graphene Research Institute, Sejong University, Seoul 143-747 (Korea, Republic of)

    2015-07-20

    A transistor structure composed of an individual single-walled carbon nanotube (SWNT) channel with a graphene electrode was demonstrated. The integrated arrays of transistor devices were prepared by transferring patterned graphene electrode patterns on top of the aligned SWNT along one direction. Both single and multi layer graphene were used for the electrode materials; typical p-type transistor and Schottky diode behavior were observed, respectively. Based on our fabrication method and device performances, several issues are suggested and discussed to improve the device reliability and finally to realize all carbon based future electronic systems.

  20. Three-dimensional electrode array for brain slice culture

    DEFF Research Database (Denmark)

    Vazquez Rodriguez, Patricia

    Multielektroder arrays (MEA) er rækker af elektroder mest i mikrometer størrelse, som er blevet brugt i stor omfang til at stimulere og måle elektrisk aktivitet fra neuronale netværker. Brug af disse for at analysere hjerne slices (hjerneskiver) kan give indsigt i interaktioner mellem neuroner, e...

  1. A foldable electrode array for 3D recording of deep-seated abnormal brain cavities

    Science.gov (United States)

    Kil, Dries; De Vloo, Philippe; Fierens, Guy; Ceyssens, Frederik; Hunyadi, Borbála; Bertrand, Alexander; Nuttin, Bart; Puers, Robert

    2018-06-01

    Objective. This study describes the design and microfabrication of a foldable thin-film neural implant and investigates its suitability for electrical recording of deep-lying brain cavity walls. Approach. A new type of foldable neural electrode array is presented, which can be inserted through a cannula. The microfabricated electrode is specifically designed for electrical recording of the cavity wall of thalamic lesions resulting from stroke. The proof-of-concept is demonstrated by measurements in rat brain cavities. On implantation, the electrode array unfolds in the brain cavity, contacting the cavity walls and allowing recording at multiple anatomical locations. A three-layer microfabrication process based on UV-lithography and Reactive Ion Etching is described. Electrochemical characterization of the electrode is performed in addition to an in vivo experiment in which the implantation procedure and the unfolding of the electrode are tested and visualized. Main results. Electrochemical characterization validated the suitability of the electrode for in vivo use. CT imaging confirmed the unfolding of the electrode in the brain cavity and analysis of recorded local field potentials showed the ability to record neural signals of biological origin. Significance. The conducted research confirms that it is possible to record neural activity from the inside wall of brain cavities at various anatomical locations after a single implantation procedure. This opens up possibilities towards research of abnormal brain cavities and the clinical conditions associated with them, such as central post-stroke pain.

  2. Multi-electrode array technologies for neuroscience and cardiology

    Science.gov (United States)

    Spira, Micha E.; Hai, Aviad

    2013-02-01

    At present, the prime methodology for studying neuronal circuit-connectivity, physiology and pathology under in vitro or in vivo conditions is by using substrate-integrated microelectrode arrays. Although this methodology permits simultaneous, cell-non-invasive, long-term recordings of extracellular field potentials generated by action potentials, it is 'blind' to subthreshold synaptic potentials generated by single cells. On the other hand, intracellular recordings of the full electrophysiological repertoire (subthreshold synaptic potentials, membrane oscillations and action potentials) are, at present, obtained only by sharp or patch microelectrodes. These, however, are limited to single cells at a time and for short durations. Recently a number of laboratories began to merge the advantages of extracellular microelectrode arrays and intracellular microelectrodes. This Review describes the novel approaches, identifying their strengths and limitations from the point of view of the end users -- with the intention to help steer the bioengineering efforts towards the needs of brain-circuit research.

  3. Classification of monofloral honeys by voltammetric electronic tongue with chemometrics method

    Energy Technology Data Exchange (ETDEWEB)

    Wei Zhenbo [Department of Bio-systems Engineering, Zhejiang University, 268 Kaixuan Road, Hangzhou 310029, Zhejiang (China); Wang Jun, E-mail: jwang@zju.edu.cn [Department of Bio-systems Engineering, Zhejiang University, 268 Kaixuan Road, Hangzhou 310029, Zhejiang (China)

    2011-05-01

    Highlights: > We self-developed a voltammetric electronic tongue based on new sensors array. > We advanced a new method to extract eigenvalues from signals obtained by VE-tongue. > We first detected the monofloral honeys of different floral origins using VE-tongue. - Abstract: A voltammetric electronic tongue (VE-tongue) based on multifrequency large amplitude pulse voltammetry (MLAPV) was developed to classify monofloral honeys of seven kinds of floral origins. The VE-tongue was composed of six working electrodes (gold, silver, platinum, palladium, tungsten, and titanium) in a standard three-electrode configuration. The applied waveform of MLAPV was composed of four individual frequencies: 1 Hz, 10 Hz, 100 Hz, and 1000 Hz. Two eigenvalues (the maximum value and the minimum value) of each cycle were extracted for building the first database (FDB); four eigenvalues (the maximum value, the minimum value, and two inflexion values) were exacted for building the second database (SDB). The two databases were analyzed by three-pattern recognition techniques: principal component analysis (PCA), discriminant function analysis (DFA) and cluster analysis (CA), respectively. It was possible to discriminate the seven kinds of honeys of different floral origins completely based on FDB and SDB by PCA, DFA and CA, and FDB was certificated as an efficient database by contrasting with the SDB. Moreover, the effective working electrodes and frequencies were picked out as the best experimental project for the further study.

  4. Hydrogen peroxide biosensor based on microperoxidase-11 immobilized in a silica cavity array electrode.

    Science.gov (United States)

    Tian, Shu; Zhou, Qun; Gu, Zhuomin; Gu, Xuefang; Zhao, Lili; Li, Yan; Zheng, Junwei

    2013-03-30

    Hydrogen peroxide biosensor based on the silica cavity array modified indium-doped tin oxide (ITO) electrode was constructed. An array of silica microcavities was fabricated by electrodeposition using the assembled polystyrene particles as template. Due to the resistance gradient of the silica cavity structure, the silica cavity exhibits a confinement effect on the electrochemical reactions, making the electrode function as an array of "soft" microelectrodes. The covalently immobilized microperoxidase-11(MP-11) inside these SiO2 cavities can keep its physiological activities, the electron transfer between the MP-11 and electrode was investigated through electrochemical method. The cyclic voltammetric curve shows a quasi-reversible electrochemical redox behavior with a pair of well-defined redox peaks, the cathodic and anodic peaks are located at -0.26 and -0.15V. Furthermore, the modified electrode exhibits high electrocatalytic activity toward the reduction of hydrogen peroxide and also shows good analytical performance for the amperometric detection of H2O2 with a linear range from 2×10(-6) to 6×10(-4)M. The good reproducibility and long-term stability of this novel electrode not only offer an opportunity for the detection of H2O2 in low concentration, but also provide a platform to construct various biosensors based on many other enzymes. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Photoelectrocatalytic activity of a hydrothermally grown branched Zno nanorod-array electrode for paracetamol degradation.

    Science.gov (United States)

    Lin, Chin Jung; Liao, Shu-Jun; Kao, Li-Cheng; Liou, Sofia Ya Hsuan

    2015-06-30

    Hierarchical branched ZnO nanorod (B-ZnR) arrays as an electrode for efficient photoelectrocatalytic degradation of paracetamol were grown on fluorine-doped tin oxide substrates using a solution route. The morphologic and structural studies show the ZnO trunks are single-crystalline hexagonal wurtzite ZnO with a [0001] growth direction and are densely covered by c-axis-oriented ZnO branches. The obvious enhancement in photocurrent response of the B-ZnR electrode was obtained than that in the ZnO nanoparticle (ZnO NP) electrode. For the photoelectrocatalytic degradation of paracetamol in 20 h, the conversion fraction of the drug increased from 32% over ZnO NP electrode to 62% over B-ZnR arrays with about 3-fold increase in initial reaction rate. The light intensity-dependent photoelectrocatalytic experiment indicated that the superior performance over the B-ZnR electrode was mainly ascribed to the increased specific surface area without significantly sacrificing the charge transport and pollutant diffusion efficiencies. Two aromatic intermediate compounds were observed and eventually converted into harmless carboxylic acids and ammonia. Hierarchical tree-like ZnO arrays can be considered effective alternatives to improve photoelectro degradation rates without the need for expensive additives. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Reliability of spring interconnects for high channel-count polyimide electrode arrays

    Science.gov (United States)

    Khan, Sharif; Ordonez, Juan Sebastian; Stieglitz, Thomas

    2018-05-01

    Active neural implants with a high channel-count need robust and reliable operational assembly for the targeted environment in order to be classified as viable fully implantable systems. The discrete functionality of the electrode array and the implant electronics is vital for intact assembly. A critical interface exists at the interconnection sites between the electrode array and the implant electronics, especially in hybrid assemblies (e.g. retinal implants) where electrodes and electronics are not on the same substrate. Since the interconnects in such assemblies cannot be hermetically sealed, reliable protection against the physiological environment is essential for delivering high insulation resistance and low defusibility of salt ions, which are limited in complexity by current assembly techniques. This work reports on a combination of spring-type interconnects on a polyimide array with silicone rubber gasket insulation for chronically active implantable systems. The spring design of the interconnects on the backend of the electrode array compensates for the uniform thickness of the sandwiched gasket during bonding in assembly and relieves the propagation of extrinsic stresses to the bulk polyimide substrate. The contact resistance of the microflex-bonded spring interconnects with the underlying metallized ceramic test vehicles and insulation through the gasket between adjacent contacts was investigated against the MIL883 standard. The contact and insulation resistances remained stable in the exhausting environmental conditions.

  7. Fabrication of nickel hydroxide electrodes with open-ended hexagonal nanotube arrays for high capacitance supercapacitors.

    Science.gov (United States)

    Wu, Mao-Sung; Huang, Kuo-Chih

    2011-11-28

    A nickel hydroxide electrode with open-ended hexagonal nanotube arrays, prepared by hydrolysis of nickel chloride in the presence of hexagonal ZnO nanorods, shows a very high capacitance of 1328 F g(-1) at a discharge current density of 1 A g(-1) due to the significantly improved ion transport.

  8. High performance flexible pH sensor based on polyaniline nanopillar array electrode.

    Science.gov (United States)

    Yoon, Jo Hee; Hong, Seok Bok; Yun, Seok-Oh; Lee, Seok Jae; Lee, Tae Jae; Lee, Kyoung G; Choi, Bong Gill

    2017-03-15

    Flexible pH sensor technologies have attracted a great deal of attention in many applications, such as, wearable health care devices and monitors for chemical and biological processes. Here, we fabricated flexible and thin pH sensors using a two electrode configuration comprised of a polyaniline nanopillar (PAN) array working electrode and an Ag/AgCl reference electrode. In order to provide nanostructure, soft lithography using a polymeric blend was employed to create a flexible nanopillar backbone film. Polyaniline-sensing materials were deposited on a patterned-nanopillar array by electrochemical deposition. The pH sensors produced exhibited a near-Nernstian response (∼60.3mV/pH), which was maintained in a bent state. In addition, pH sensors showed other excellent sensor performances in terms of response time, reversibility, repeatability, selectivity, and stability. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Silver-nickel oxide core-shell nanoparticle array electrode with enhanced lithium-storage performance

    International Nuclear Information System (INIS)

    Zhao, Wenjia; Du, Ning; Zhang, Hui; Yang, Deren

    2015-01-01

    We demonstrate the synthesis of Ag-NiO core-shell nanoparticle arrays via a one-step solution-immersion process and subsequent RF-sputtering technique. The Ag nanoparticle arrays on copper substrate are firstly prepared by a displacement reaction at mild temperature of 303K. Then, a NiO layer is deposited onto the surface of the Ag nanoparticles via RF-sputtering technique. When evaluated as an anode for lithium-ion batteries, the Ag-NiO core-shell electrode shows higher capacity and better cycling performance than the planar NiO electrode. The in-situ synthesized Ag nanoparticles can enhance the interfacial strength between the active material and substrate, andimprove the electrical conductivity of the electrode, which may be responsible for the enhanced performance

  10. High Density Nano-Electrode Array for Radiation Detection

    International Nuclear Information System (INIS)

    Misra, Mano

    2010-01-01

    Bulk single crystals of Cd 1-x Zn x Te (x=0.04 to x=0.2) compound semiconductor is used for room temperature radiation detection. The production of large volume of Cd 1-x Zn x Te with low defect density is expensive. As a result there is a growing research interest in the production of nanostructured compound semiconductors such as Cd 1-x Zn x Te in an electrochemical route. In this investigation, Cd 1-x Zn x Te ternary compound semiconductor, referred as CZT, was electrodeposited in the form of nanowires onto a TiO 2 nanotubular template from propylene carbonate as the non-aqueous electrolyte, using a pulse-reverse electrodeposition process at 130 C. The template acted as a support in growing ordered nanowire of CZT which acts as a one dimensional conductor. Cyclic Voltammogram (CV) studies were conducted in determining the potentials for the growth of nanowires of uniform stoichiometry. The morphologies and composition of CZT were characterized by using SEM, TEM and XRD. The STEM mapping carried out on the nanowires showed the uniform distribution of Cd, Zn and Te elements. TEM image showed that the nanowires were polycrystalline in nature. The Mott-Schottky analysis carried on the nanowires showed that the nanowires were a p-type semiconductor. The carrier density, band gap and resistivity of the Cd 0.9 Zn 0.1 Te nanowires were 4.29 x 10 13 cm -3 , 1.56 eV and 2.76 x 10 11 (Omega)-cm respectively. The high resistivity was attributed to the presence of deep defect states such as cadmium vacancies or Te antisites which were created by the anodic cycle of the pulse-reverse electrodeposition process. Stacks of series connected CZT nanowire arrays were tested with different bias potentials. The background current was in the order of tens of picoamperes. When exposed to radiation source Amerecium-241 (60 KeV, 4 (micro)Ci), the stacked CZT nanowires arrays showed sensing behavior. The sensitivity of the nanowire arrays increased as the number of stacks increased. The

  11. Biochips Containing Arrays of Carbon-Nanotube Electrodes

    Science.gov (United States)

    Li, Jun; Meyyappan, M.; Koehne, Jessica; Cassell, Alan; Chen, Hua

    2008-01-01

    Biochips containing arrays of nanoelectrodes based on multiwalled carbon nanotubes (MWCNTs) are being developed as means of ultrasensitive electrochemical detection of specific deoxyribonucleic acid (DNA) and messenger ribonucleic acid (mRNA) biomarkers for purposes of medical diagnosis and bioenvironmental monitoring. In mass production, these biochips could be relatively inexpensive (hence, disposable). These biochips would be integrated with computer-controlled microfluidic and microelectronic devices in automated hand-held and bench-top instruments that could be used to perform rapid in vitro genetic analyses with simplified preparation of samples. Carbon nanotubes are attractive for use as nanoelectrodes for detection of biomolecules because of their nanoscale dimensions and their chemical properties.

  12. High Density Nano-Electrode Array for Radiation Detection

    Energy Technology Data Exchange (ETDEWEB)

    Mano Misra

    2010-05-07

    Bulk single crystals of Cd1-xZnxTe (x=0.04 to x=0.2) compound semiconductor is used for room temperature radiation detection. The production of large volume of Cd1-xZnxTe with low defect density is expensive. As a result there is a growing research interest in the production of nanostructured compound semiconductors such as Cd1-xZnxTe in an electrochemical route. In this investigation, Cd1-xZnxTe ternary compound semiconductor, referred as CZT, was electrodeposited in the form of nanowires onto a TiO2 nanotubular template from propylene carbonate as the non-aqueous electrolyte, using a pulse-reverse electrodeposition process at 130 ºC. The template acted as a support in growing ordered nanowire of CZT which acts as a one dimensional conductor. Cyclic Voltammogram (CV) studies were conducted in determining the potentials for the growth of nanowires of uniform stoichiometry. The morphologies and composition of CZT were characterized by using SEM, TEM and XRD. The STEM mapping carried out on the nanowires showed the uniform distribution of Cd, Zn and Te elements. TEM image showed that the nanowires were polycrystalline in nature. The Mott-Schottky analysis carried on the nanowires showed that the nanowires were a p-type semiconductor. The carrier density, band gap and resistivity of the Cd0.9Zn0.1Te nanowires were 4.29x1013 cm-3, 1.56 eV and 2.76x1011Ω-cm respectively. The high resistivity was attributed to the presence of deep defect states such as cadmium vacancies or Te antisites which were created by the anodic cycle of the pulse-reverse electrodeposition process. Stacks of series connected CZT nanowire arrays were tested with different bias potentials. The background current was in the order of tens of picoamperes. When exposed to radiation source Amerecium-241 (60 KeV, 4 μCi), the stacked CZT nanowires arrays showed sensing behavior. The sensitivity of the nanowire arrays increased as the number of stacks increased. The preliminary results indicate that the

  13. Design of micro, flexible light-emitting diode arrays and fabrication of flexible electrodes

    International Nuclear Information System (INIS)

    Gao, Dan; Wang, Weibiao; Liang, Zhongzhu; Liang, Jingqiu; Qin, Yuxin; Lv, Jinguang

    2016-01-01

    In this study, we design micro, flexible light-emitting diode (LED) array devices. Using theoretical calculations and finite element simulations, we analyze the deformation of the conventional single electrode bar. Through structure optimization, we obtain a three-dimensional (3D), chain-shaped electrode structure, which has a greater bending degree. The optimized electrodes not only have a bigger bend but can also be made to spin. When the supporting body is made of polydimethylsiloxane (PDMS), the maximum bending degree of the micro, flexible LED arrays (4  ×  1 arrays) was approximately 230 µ m; this was obtained using the finite element method. The device (4  ×  1 arrays) can stretch to 15%. This paper describes the fabrication of micro, flexible LED arrays using microelectromechancial (MEMS) technology combined with electroplating technology. Specifically, the isolated grooves are made by dry etching which can isolate and protect the light-emitting units. A combination of MEMS technology and wet etching is used to fabricate the large size spacing. (paper)

  14. Intracellular Protein Delivery and Gene Transfection by Electroporation Using a Microneedle Electrode Array

    Science.gov (United States)

    Choi, Seong-O; Kim, Yeu-Chun; Lee, Jeong Woo; Park, Jung-Hwan

    2012-01-01

    The impact of many biopharmaceuticals, including protein- and gene-based therapies, has been limited by the need for better methods of delivery into cells within tissues. Here, we present intracellular delivery of molecules and transfection with plasmid DNA by electroporation using a novel microneedle electrode array designed for targeted treatment of skin and other tissue surfaces. The microneedle array is molded out of polylactic acid. Electrodes and circuitry required for electroporation are applied to the microneedle array surface by a new metal-transfer micromolding method. The microneedle array maintains mechanical integrity after insertion into pig cadaver skin and is able to electroporate human prostate cancer cells in vitro. Quantitative measurements show that increasing electroporation pulse voltage increases uptake efficiency of calcein and bovine serum albumin, whereas increasing pulse length has lesser effects over the range studied. Uptake of molecules by up to 50 % of cells and transfection of 12 % of cells with a gene for green fluorescent protein is demonstrated at high cell viability. We conclude that the microneedle electrode array is able to electroporate cells, resulting in intracellular uptake of molecules, and has potential applications to improve intracellular delivery of proteins, DNA and other biopharmaceuticals. PMID:22328093

  15. Flexible Supercapacitors Based on Polyaniline Arrays Coated Graphene Aerogel Electrodes.

    Science.gov (United States)

    Yang, Yu; Xi, Yunlong; Li, Junzhi; Wei, Guodong; Klyui, N I; Han, Wei

    2017-12-01

    Flexible supercapacitors(SCs) made by reduced graphene oxide (rGO)-based aerogel usually suffer from the low energy density, short cycle life and bad flexibility. In this study, a new, synthetic strategy was developed for enhancing the electrochemical performances of rGO aerogel-based supercapacitor via electrodeposition polyaniline arrays on the prepared ultralight rGO aerogel. The novel hybrid composites with coated polyaniline (PANI) arrays growing on the rGO surface can take full advantage of the rich open-pore and excellent conductivity of the crosslinking framework structure of 3D rGO aerogel and high capacitance contribution from the PANI. The obtained hybrid composites exhibit excellent electrochemical performance with a specific capacitance of 432 F g -1 at the current density of 1 A g -1 , robust cycling stability to maintain 85% after 10,000 charge/discharge cycles and high energy density of 25 W h kg -1 . Furthermore, the flexible all-solid-state supercapacitor have superior flexibility and outstanding stability under different bending states from the straight state to the 90° status. The high-performance flexible all-solid-state SCs together with the lighting tests demonstrate it possible for applications in portable electronics.

  16. Mapping the fine structure of cortical activity with different micro-ECoG electrode array geometries

    Science.gov (United States)

    Wang, Xi; Gkogkidis, C. Alexis; Iljina, Olga; Fiederer, Lukas D. J.; Henle, Christian; Mader, Irina; Kaminsky, Jan; Stieglitz, Thomas; Gierthmuehlen, Mortimer; Ball, Tonio

    2017-10-01

    Objective. Innovations in micro-electrocorticography (µECoG) electrode array manufacturing now allow for intricate designs with smaller contact diameters and/or pitch (i.e. inter-contact distance) down to the sub-mm range. The aims of the present study were: (i) to investigate whether frequency ranges up to 400 Hz can be reproducibly observed in µECoG recordings and (ii) to examine how differences in topographical substructure between these frequency bands and electrode array geometries can be quantified. We also investigated, for the first time, the influence of blood vessels on signal properties and assessed the influence of cortical vasculature on topographic mapping. Approach. The present study employed two µECoG electrode arrays with different contact diameters and inter-contact distances, which were used to characterize neural activity from the somatosensory cortex of minipigs in a broad frequency range up to 400 Hz. The analysed neural data were recorded in acute experiments under anaesthesia during peripheral electrical stimulation. Main results. We observed that µECoG recordings reliably revealed multi-focal cortical somatosensory response patterns, in which response peaks were often less than 1 cm apart and would thus not have been resolvable with conventional ECoG. The response patterns differed by stimulation site and intensity, they were distinct for different frequency bands, and the results of functional mapping proved independent of cortical vascular. Our analysis of different frequency bands exhibited differences in the number of activation peaks in topographical substructures. Notably, signal strength and signal-to-noise ratios differed between the two electrode arrays, possibly due to their different sensitivity for variations in spatial patterns and signal strengths. Significance. Our findings that the geometry of µECoG electrode arrays can strongly influence their recording performance can help to make informed decisions that maybe

  17. Hierarchical mesoporous nickel cobaltite nanoneedle/carbon cloth arrays as superior flexible electrodes for supercapacitors

    Science.gov (United States)

    2014-01-01

    Hierarchical mesoporous NiCo2O4 nanoneedle arrays on carbon cloth have been fabricated by a simple hydrothermal approach combined with a post-annealing treatment. Such unique array nanoarchitectures exhibit remarkable electrochemical performance with high capacitance and desirable cycle life at high rates. When evaluated as an electrode material for supercapacitors, the NiCo2O4 nanoneedle arrays supported on carbon cloth was able to deliver high specific capacitance of 660 F g-1 at current densities of 2 A g-1 in 2 M KOH aqueous solution. In addition, the composite electrode shows excellent mechanical behavior and long-term cyclic stability (91.8% capacitance retention after 3,000 cycles). The fabrication method presented here is facile, cost-effective, and scalable, which may open a new pathway for real device applications. PMID:24661431

  18. Tungsten oxide@polypyrrole core-shell nanowire arrays as novel negative electrodes for asymmetric supercapacitors.

    Science.gov (United States)

    Wang, Fengmei; Zhan, Xueying; Cheng, Zhongzhou; Wang, Zhenxing; Wang, Qisheng; Xu, Kai; Safdar, Muhammad; He, Jun

    2015-02-11

    Among active pseudocapacitive materials, polypyrrole (PPy) is a promising electrode material in electrochemical capacitors. PPy-based materials research has thus far focused on its electrochemical performance as a positive electrode rather than as a negative electrode for asymmetric supercapacitors (ASCs). Here high-performance electrochemical supercapacitors are designed with tungsten oxide@PPy (WO3 @PPy) core-shell nanowire arrays and Co(OH)2 nanowires grown on carbon fibers. The WO3 @PPy core-shell nanowire electrode exhibits a high capacitance (253 mF/cm2) in negative potentials (-1.0-0.0 V). The ASCs packaged with CF-Co(OH)2 as a positive electrode and CF-WO3 @PPy as a negative electrode display a high volumetric capacitance up to 2.865 F/cm3 based on volume of the device, an energy density of 1.02 mWh/cm3 , and very good stability performance. These findings promote the application of PPy-based nanostructures as advanced negative electrodes for ASCs. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Polyaniline nanowire array encapsulated in titania nanotubes as a superior electrode for supercapacitors

    Science.gov (United States)

    Xie, Keyu; Li, Jie; Lai, Yanqing; Zhang, Zhi'an; Liu, Yexiang; Zhang, Guoge; Huang, Haitao

    2011-05-01

    Conducting polymer with 1D nanostructure exhibits excellent electrochemical performances but a poor cyclability that limits its use in supercapacitors. In this work, a novel composite electrode made of polyaniline nanowire-titania nanotube array was synthesized via a simple and inexpensive electrochemical route by electropolymerizing aniline onto an anodized titania nanotube array. The specific capacitance was as high as 732 F g-1 at 1 A g-1, which remained at 543 F g-1 when the current density was increased by 20 times. 74% of the maximum energy density (36.6 Wh kg-1) was maintained even at a high power density of 6000 W kg-1. An excellent long cycle life of the electrode was observed with a retention of ~86% of the initial specific capacitance after 2000 cycles. The good electrochemical performance was attributed to the unique microstructure of the electrode with disordered PANI nanowire arrays encapsulated inside the TiO2 nanotubes, providing high surface area, fast diffusion path for ions and long-term cycle stability. Such a nanocomposite electrode is attractive for supercapacitor applications.

  20. A novel screen-printed electrode array for rapid high-throughput detection.

    Science.gov (United States)

    Mu, Shuai; Wang, Xiao; Li, Yuan-Ting; Wang, Yang; Li, Da-Wei; Long, Yi-Tao

    2012-07-21

    A novel multi-channel electrode array sensing device was fabricated by screen-printing techniques using 96-well plate as the template. To confirm its practical value, we developed a one-step preparation of multi-walled carbon nanotubes (MWCNTs) doped electrode array by an ink containing MWCNTs, which was applied to the simultaneous detection of a variety of biological samples and environmental pollutants. Results demonstrated that the designed sensing device could carry out the multiple measurements of different analytes at the same time, while MWCNTs enhanced the electrocatalytic activity of electrodes toward electroactive molecules. The required amount of each sample was only ∼200 μL. Moreover, the excellent differential pulse voltammetric (DPV) response toward dopamine, hydroquinone and catechol was obtained and the detection limits was determined to be 0.337, 0.289 and 0.369 μM, respectively. Comparing it with the traditional screen-printed electrode (SPE), this sensing device possesses the advantages of high-throughput, fast electron transfer rate for electrodes, short-time analysis and low sample consumption.

  1. Fabrication of Flexible Microneedle Array Electrodes for Wearable Bio-Signal Recording.

    Science.gov (United States)

    Ren, Lei; Xu, Shujia; Gao, Jie; Lin, Zi; Chen, Zhipeng; Liu, Bin; Liang, Liang; Jiang, Lelun

    2018-04-13

    Laser-direct writing (LDW) and magneto-rheological drawing lithography (MRDL) have been proposed for the fabrication of a flexible microneedle array electrode (MAE) for wearable bio-signal monitoring. Conductive patterns were directly written onto the flexible polyethylene terephthalate (PET) substrate by LDW. The microneedle array was rapidly drawn and formed from the droplets of curable magnetorheological fluid with the assistance of an external magnetic field by MRDL. A flexible MAE can maintain a stable contact interface with curved human skin due to the flexibility of the PET substrate. Compared with Ag/AgCl electrodes and flexible dry electrodes (FDE), the electrode-skin interface impedance of flexible MAE was the minimum even after a 50-cycle bending test. Flexible MAE can record electromyography (EMG), electroencephalography (EEG) and static electrocardiography (ECG) signals with good fidelity. The main features of the dynamic ECG signal recorded by flexible MAE are the most distinguishable with the least moving artifacts. Flexible MAE is an attractive candidate electrode for wearable bio-signal monitoring.

  2. Improving Impedance of Implantable Microwire Multi-Electrode Arrays by Ultrasonic Electroplating of Durable Platinum Black

    Science.gov (United States)

    Desai, Sharanya Arcot; Rolston, John D.; Guo, Liang; Potter, Steve M.

    2010-01-01

    Implantable microelectrode arrays (MEAs) have been a boon for neural stimulation and recording experiments. Commercially available MEAs have high impedances, due to their low surface area and small tip diameters, which are suitable for recording single unit activity. Lowering the electrode impedance, but preserving the small diameter, would provide a number of advantages, including reduced stimulation voltages, reduced stimulation artifacts and improved signal-to-noise ratio. Impedance reductions can be achieved by electroplating the MEAs with platinum (Pt) black, which increases the surface area but has little effect on the physical extent of the electrodes. However, because of the low durability of Pt black plating, this method has not been popular for chronic use. Sonicoplating (i.e. electroplating under ultrasonic agitation) has been shown to improve the durability of Pt black on the base metals of macro-electrodes used for cyclic voltammetry. This method has not previously been characterized for MEAs used in chronic neural implants. We show here that sonicoplating can lower the impedances of microwire multi-electrode arrays (MMEA) by an order of magnitude or more (depending on the time and voltage of electroplating), with better durability compared to pulsed plating or traditional DC methods. We also show the improved stimulation and recording performance that can be achieved in an in vivo implantation study with the sonicoplated low-impedance MMEAs, compared to high-impedance unplated electrodes. PMID:20485478

  3. Preparation of Janus Particles and Alternating Current Electrokinetic Measurements with a Rapidly Fabricated Indium Tin Oxide Electrode Array.

    Science.gov (United States)

    Chen, Yu-Liang; Jiang, Hong-Ren

    2017-06-23

    This article provides a simple method to prepare partially or fully coated metallic particles and to perform the rapid fabrication of electrode arrays, which can facilitate electrical experiments in microfluidic devices. Janus particles are asymmetric particles that contain two different surface properties on their two sides. To prepare Janus particles, a monolayer of silica particles is prepared by a drying process. Gold (Au) is deposited on one side of each particle using a sputtering device. The fully coated metallic particles are completed after the second coating process. To analyze the electrical surface properties of Janus particles, alternating current (AC) electrokinetic measurements, such as dielectrophoresis (DEP) and electrorotation (EROT)- which require specifically designed electrode arrays in the experimental device- are performed. However, traditional methods to fabricate electrode arrays, such as the photolithographic technique, require a series of complicated procedures. Here, we introduce a flexible method to fabricate a designed electrode array. An indium tin oxide (ITO) glass is patterned by a fiber laser marking machine (1,064 nm, 20 W, 90 to 120 ns pulse-width, and 20 to 80 kHz pulse repetition frequency) to create a four-phase electrode array. To generate the four-phase electric field, the electrodes are connected to a 2-channel function generator and to two invertors. The phase shift between the adjacent electrodes is set at either 90° (for EROT) or 180° (for DEP). Representative results of AC electrokinetic measurements with a four-phase ITO electrode array are presented.

  4. Action potential propagation recorded from single axonal arbors using multi-electrode arrays.

    Science.gov (United States)

    Tovar, Kenneth R; Bridges, Daniel C; Wu, Bian; Randall, Connor; Audouard, Morgane; Jang, Jiwon; Hansma, Paul K; Kosik, Kenneth S

    2018-04-11

    We report the presence of co-occurring extracellular action potentials (eAPs) from cultured mouse hippocampal neurons among groups of planar electrodes on multi-electrode arrays (MEAs). The invariant sequences of eAPs among co-active electrode groups, repeated co-occurrences and short inter-electrode latencies are consistent with action potential propagation in unmyelinated axons. Repeated eAP co-detection by multiple electrodes was widespread in all our data records. Co-detection of eAPs confirms they result from the same neuron and allows these eAPs to be isolated from all other spikes independently of spike sorting algorithms. We averaged co-occurring events and revealed additional electrodes with eAPs that would otherwise be below detection threshold. We used these eAP cohorts to explore the temperature sensitivity of action potential propagation and the relationship between voltage-gated sodium channel density and propagation velocity. The sequence of eAPs among co-active electrodes 'fingerprints' neurons giving rise to these events and identifies them within neuronal ensembles. We used this property and the non-invasive nature of extracellular recording to monitor changes in excitability at multiple points in single axonal arbors simultaneously over several hours, demonstrating independence of axonal segments. Over several weeks, we recorded changes in inter-electrode propagation latencies and ongoing changes in excitability in different regions of single axonal arbors. Our work illustrates how repeated eAP co-occurrences can be used to extract physiological data from single axons with low electrode density MEAs. However, repeated eAP co-occurrences leads to over-sampling spikes from single neurons and thus can confound traditional spike-train analysis.

  5. Investigation of a new electrode array technology for a central auditory prosthesis.

    Directory of Open Access Journals (Sweden)

    Roger Calixto

    Full Text Available Ongoing clinical studies on patients recently implanted with the auditory midbrain implant (AMI into the inferior colliculus (IC for hearing restoration have shown that these patients do not achieve performance levels comparable to cochlear implant patients. The AMI consists of a single-shank array (20 electrodes for stimulation along the tonotopic axis of the IC. Recent findings suggest that one major limitation in AMI performance is the inability to sufficiently activate neurons across the three-dimensional (3-D IC. Unfortunately, there are no currently available 3-D array technologies that can be used for clinical applications. More recently, there has been a new initiative by the European Commission to fund and develop 3-D chronic electrode arrays for science and clinical applications through the NeuroProbes project that can overcome the bulkiness and limited 3-D configurations of currently available array technologies. As part of the NeuroProbes initiative, we investigated whether their new array technology could be potentially used for future AMI patients. Since the NeuroProbes technology had not yet been tested for electrical stimulation in an in vivo animal preparation, we performed experiments in ketamine-anesthetized guinea pigs in which we inserted and stimulated a NeuroProbes array within the IC and recorded the corresponding neural activation within the auditory cortex. We used 2-D arrays for this initial feasibility study since they were already available and were sufficient to access the IC and also demonstrate effective activation of the central auditory system. Based on these encouraging results and the ability to develop customized 3-D arrays with the NeuroProbes technology, we can further investigate different stimulation patterns across the ICC to improve AMI performance.

  6. Optimization of focality and direction in dense electrode array transcranial direct current stimulation (tDCS)

    Science.gov (United States)

    Guler, Seyhmus; Dannhauer, Moritz; Erem, Burak; Macleod, Rob; Tucker, Don; Turovets, Sergei; Luu, Phan; Erdogmus, Deniz; Brooks, Dana H.

    2016-06-01

    Objective. Transcranial direct current stimulation (tDCS) aims to alter brain function non-invasively via electrodes placed on the scalp. Conventional tDCS uses two relatively large patch electrodes to deliver electrical current to the brain region of interest (ROI). Recent studies have shown that using dense arrays containing up to 512 smaller electrodes may increase the precision of targeting ROIs. However, this creates a need for methods to determine effective and safe stimulus patterns as the number of degrees of freedom is much higher with such arrays. Several approaches to this problem have appeared in the literature. In this paper, we describe a new method for calculating optimal electrode stimulus patterns for targeted and directional modulation in dense array tDCS which differs in some important aspects with methods reported to date. Approach. We optimize stimulus pattern of dense arrays with fixed electrode placement to maximize the current density in a particular direction in the ROI. We impose a flexible set of safety constraints on the current power in the brain, individual electrode currents, and total injected current, to protect subject safety. The proposed optimization problem is convex and thus efficiently solved using existing optimization software to find unique and globally optimal electrode stimulus patterns. Main results. Solutions for four anatomical ROIs based on a realistic head model are shown as exemplary results. To illustrate the differences between our approach and previously introduced methods, we compare our method with two of the other leading methods in the literature. We also report on extensive simulations that show the effect of the values chosen for each proposed safety constraint bound on the optimized stimulus patterns. Significance. The proposed optimization approach employs volume based ROIs, easily adapts to different sets of safety constraints, and takes negligible time to compute. An in-depth comparison study gives

  7. Bipolar Electrode Array Embedded in a Polymer Light-Emitting Electrochemical Cell.

    Science.gov (United States)

    Gao, Jun; Chen, Shulun; AlTal, Faleh; Hu, Shiyu; Bouffier, Laurent; Wantz, Guillaume

    2017-09-20

    A linear array of aluminum discs is deposited between the driving electrodes of an extremely large planar polymer light-emitting electrochemical cell (PLEC). The planar PLEC is then operated at a constant bias voltage of 100 V. This promotes in situ electrochemical doping of the luminescent polymer from both the driving electrodes and the aluminum discs. These aluminum discs function as discrete bipolar electrodes (BPEs) that can drive redox reactions at their extremities. Time-lapse fluorescence imaging reveals that p- and n-doping that originated from neighboring BPEs can interact to form multiple light-emitting p-n junctions in series. This provides direct evidence of the working principle of bulk homojunction PLECs. The propagation of p-doping is faster from the BPEs than from the positive driving electrode due to electric field enhancement at the extremities of BPEs. The effect of field enhancement and the fact that the doping fronts only need to travel the distance between the neighboring BPEs to form a light-emitting junction greatly reduce the response time for electroluminescence in the region containing the BPE array. The near simultaneous formation of multiple light-emitting p-n junctions in series causes a measurable increase in cell current. This indicates that the region containing a BPE is much more conductive than the rest of the planar cell despite the latter's greater width. The p- and n-doping originating from the BPEs is initially highly confined. Significant expansion and divergence of doping occurred when the region containing the BPE array became more conductive. The shape and direction of expanded doping strongly suggest that the multiple light-emitting p-n junctions, formed between and connected by the array of metal BPEs, have functioned as a single rod-shaped BPE. This represents a new type of BPE that is formed in situ and as a combination of metal, doped polymers, and forward-biased p-n junctions connected in series.

  8. Stable switching of resistive random access memory on the nanotip array electrodes

    KAUST Repository

    Tsai, Kun-Tong

    2016-09-13

    The formation/rupture of conducting filaments (CFs) in resistive random access memory (ReRAM) materials tune the electrical conductivities non-volatilely and are largely affected by its material composition [1], internal configurations [2] and external environments [3,4]. Therefore, controlling repetitive formation/rupture of CF as well as the spatial uniformity of formed CF are fundamentally important for improving the resistive switching (RS) performance. In this context, we have shown that by adding a field initiator, typically a textured electrode, both performance and switching uniformity of ReRAMs can be improved dramatically [5]. In addition, despite its promising characteristics, the scalable fabrication and structural homogeneity of such nanostructured electrodes are still lacking or unattainable, making miniaturization of ReRAM devices an exceeding challenge. Here, we employ nanostructured electrode (nanotip arrays, extremely uniform) formed spontaneously via a self-organized process to improve the ZnO ReRAM switching characteristics.

  9. Highly stable palladium-loaded TiO{sub 2} nanotube array electrode for the electrocatalytic hydrodehalogenation of polychlorinated biphenyls

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Chunyue; Wu, Juan; Xin, Yanjun [Qingdao Agricultural University, Qingdao (China); Han, Yanhe [Beijing Institute of Petrochemical Technology, Beijing (China)

    2015-06-15

    Palladized TiO{sub 2} nanotube array electrode was prepared for the electrocatalytic hydrodehalogenation (HDH) of 2,4,5-trichlorobiphenyl (2,4,5-PCB). The TiO{sub 2} nanotube array electrode was successfully fabricated by anodic oxidation method, and Pd was loaded onto the TiO{sub 2} nanotubes by electrochemical deposition. The morphology and structure of the nanotube array electrodes with and without Pd catalysts were evaluated by scanning electron microscopy (SEM), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS). The results showed that the diameters and lengths of the TiO{sub 2} nanotubes were 30-50 nm and 200-400 nm, respectively. The particle size of the Pd was about 12 nm. Electrocatalytic HDH of 2,4,5-PCB with the Pd/TiO{sub 2} nanotube array electrode was performed in H-cell reactor. Under a constant potential of -1.0 V, the HDH efficiency of 2,4,5-PCB was 90% and the biphenyl yield was 83% (15% current efficiency) within 180min at the Pd/TiO{sub 2} nanotube array electrode. Compared with the Pd/Ti electrode, the Pd/TiO{sub 2} nanotube array electrode exhibited higher HDH efficiency and stability. Additionally, the effect of the primary HDH factors was also investigated.

  10. Visible light photoelectrocatalysis with salicylic acid-modified TiO2 nanotube array electrode for p-nitrophenol degradation

    International Nuclear Information System (INIS)

    Wang Xin; Zhao Huimin; Quan Xie; Zhao Yazhi; Chen Shuo

    2009-01-01

    This research focused on immersion method synthesis of visible light active salicylic acid (SA)-modified TiO 2 nanotube array electrode and its photoelectrocatalytic (PEC) activity. The SA-modified TiO 2 nanotube array electrode was synthesized by immersing in SA solution with an anodized TiO 2 nanotube array electrode. Scanning electron microscope (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), infrared spectroscopy (IR), UV-vis diffuse reflectance spectrum (DRS), and Surface photovoltage (SPV) were used to characterize this electrode. It was found that SA-modified TiO 2 nanotube array electrode absorbed well into visible region and exhibited enhanced visible light PEC activity on the degradation of p-nitrophenol (PNP). The degradation efficiencies increased from 63 to 100% under UV light, and 79-100% under visible light (λ > 400 nm), compared with TiO 2 nanotube array electrode. The enhanced PEC activity of SA-modified TiO 2 nanotube array electrode was attributed to the amount of surface hydroxyl groups introduced by SA-modification and the extension of absorption wavelength range.

  11. Fabrication of Flexible Microneedle Array Electrodes for Wearable Bio-Signal Recording

    Directory of Open Access Journals (Sweden)

    Lei Ren

    2018-04-01

    Full Text Available Laser-direct writing (LDW and magneto-rheological drawing lithography (MRDL have been proposed for the fabrication of a flexible microneedle array electrode (MAE for wearable bio-signal monitoring. Conductive patterns were directly written onto the flexible polyethylene terephthalate (PET substrate by LDW. The microneedle array was rapidly drawn and formed from the droplets of curable magnetorheological fluid with the assistance of an external magnetic field by MRDL. A flexible MAE can maintain a stable contact interface with curved human skin due to the flexibility of the PET substrate. Compared with Ag/AgCl electrodes and flexible dry electrodes (FDE, the electrode–skin interface impedance of flexible MAE was the minimum even after a 50-cycle bending test. Flexible MAE can record electromyography (EMG, electroencephalography (EEG and static electrocardiography (ECG signals with good fidelity. The main features of the dynamic ECG signal recorded by flexible MAE are the most distinguishable with the least moving artifacts. Flexible MAE is an attractive candidate electrode for wearable bio-signal monitoring.

  12. Fabrication of a Micro-Needle Array Electrode by Thermal Drawing for Bio-Signals Monitoring.

    Science.gov (United States)

    Ren, Lei; Jiang, Qing; Chen, Keyun; Chen, Zhipeng; Pan, Chengfeng; Jiang, Lelun

    2016-06-17

    A novel micro-needle array electrode (MAE) fabricated by thermal drawing and coated with Ti/Au film was proposed for bio-signals monitoring. A simple and effective setup was employed to form glassy-state poly (lactic-co-glycolic acid) (PLGA) into a micro-needle array (MA) by the thermal drawing method. The MA was composed of 6 × 6 micro-needles with an average height of about 500 μm. Electrode-skin interface impedance (EII) was recorded as the insertion force was applied on the MAE. The insertion process of the MAE was also simulated by the finite element method. Results showed that MAE could insert into skin with a relatively low compression force and maintain stable contact impedance between the MAE and skin. Bio-signals, including electromyography (EMG), electrocardiography (ECG), and electroencephalograph (EEG) were also collected. Test results showed that the MAE could record EMG, ECG, and EEG signals with good fidelity in shape and amplitude in comparison with the commercial Ag/AgCl electrodes, which proves that MAE is an alternative electrode for bio-signals monitoring.

  13. Fabrication of a Micro-Needle Array Electrode by Thermal Drawing for Bio-Signals Monitoring

    Directory of Open Access Journals (Sweden)

    Lei Ren

    2016-06-01

    Full Text Available A novel micro-needle array electrode (MAE fabricated by thermal drawing and coated with Ti/Au film was proposed for bio-signals monitoring. A simple and effective setup was employed to form glassy-state poly (lactic-co-glycolic acid (PLGA into a micro-needle array (MA by the thermal drawing method. The MA was composed of 6 × 6 micro-needles with an average height of about 500 μm. Electrode-skin interface impedance (EII was recorded as the insertion force was applied on the MAE. The insertion process of the MAE was also simulated by the finite element method. Results showed that MAE could insert into skin with a relatively low compression force and maintain stable contact impedance between the MAE and skin. Bio-signals, including electromyography (EMG, electrocardiography (ECG, and electroencephalograph (EEG were also collected. Test results showed that the MAE could record EMG, ECG, and EEG signals with good fidelity in shape and amplitude in comparison with the commercial Ag/AgCl electrodes, which proves that MAE is an alternative electrode for bio-signals monitoring.

  14. Electrical stimulus artifact cancellation and neural spike detection on large multi-electrode arrays.

    Science.gov (United States)

    Mena, Gonzalo E; Grosberg, Lauren E; Madugula, Sasidhar; Hottowy, Paweł; Litke, Alan; Cunningham, John; Chichilnisky, E J; Paninski, Liam

    2017-11-01

    Simultaneous electrical stimulation and recording using multi-electrode arrays can provide a valuable technique for studying circuit connectivity and engineering neural interfaces. However, interpreting these measurements is challenging because the spike sorting process (identifying and segregating action potentials arising from different neurons) is greatly complicated by electrical stimulation artifacts across the array, which can exhibit complex and nonlinear waveforms, and overlap temporarily with evoked spikes. Here we develop a scalable algorithm based on a structured Gaussian Process model to estimate the artifact and identify evoked spikes. The effectiveness of our methods is demonstrated in both real and simulated 512-electrode recordings in the peripheral primate retina with single-electrode and several types of multi-electrode stimulation. We establish small error rates in the identification of evoked spikes, with a computational complexity that is compatible with real-time data analysis. This technology may be helpful in the design of future high-resolution sensory prostheses based on tailored stimulation (e.g., retinal prostheses), and for closed-loop neural stimulation at a much larger scale than currently possible.

  15. Long-term stability of intracortical recordings using perforated and arrayed Parylene sheath electrodes

    Science.gov (United States)

    Hara, Seth A.; Kim, Brian J.; Kuo, Jonathan T. W.; Lee, Curtis D.; Meng, Ellis; Pikov, Victor

    2016-12-01

    Objective. Acquisition of reliable and robust neural recordings with intracortical neural probes is a persistent challenge in the field of neuroprosthetics. We developed a multielectrode array technology to address chronic intracortical recording reliability and present in vivo recording results. Approach. The 2 × 2 Parylene sheath electrode array (PSEA) was microfabricated and constructed from only Parylene C and platinum. The probe includes a novel three-dimensional sheath structure, perforations, and bioactive coatings that improve tissue integration and manage immune response. Coatings were applied using a sequential dip-coating method that provided coverage over the entire probe surface and interior of the sheath structure. A sharp probe tip taper facilitated insertion with minimal trauma. Fabricated probes were subject to examination by optical and electron microscopy and electrochemical testing prior to implantation. Main results. 1 × 2 arrays were successfully fabricated on wafer and then packaged together to produce 2 × 2 arrays. Then, probes having electrode sites with adequate electrochemical properties were selected. A subset of arrays was treated with bioactive coatings to encourage neuronal growth and suppress inflammation and another subset of arrays was implanted in conjunction with a virally mediated expression of Caveolin-1. Arrays were attached to a custom-made insertion shuttle to facilitate precise insertion into the rat motor cortex. Stable electrophysiological recordings were obtained during the period of implantation up to 12 months. Immunohistochemical evaluation of cortical tissue around individual probes indicated a strong correlation between the electrophysiological performance of the probes and histologically observable proximity of neurons and dendritic sprouting. Significance. The PSEA demonstrates the scalability of sheath electrode technology and provides higher electrode count and density to access a greater volume for recording

  16. Evaluation of red wines antioxidant capacity by means of a voltammetric e-tongue with an optimized sensor array

    International Nuclear Information System (INIS)

    Cetó, Xavi; Apetrei, Constantin; Valle, Manel del; Rodríguez-Méndez, Maria Luz

    2014-01-01

    In this work, two sets of voltammetric sensors -prepared using different strategies- have been combined in an electronic tongue to evaluate the complete antioxidant profile of red wines. To this aim, wine samples were analyzed with the whole set of sensors. In order to reduce the large dimensionality of the data set while keeping the relevant information provided by the sensors, two different methods of feature selection and data compression were used (the kernels method and Discrete Wavelet Transform feature extraction method). Then, the coefficients obtained were used as the input variables of Principal Component Analysis (to evaluate the capability of discrimination. Partial-least squares regression (PLS) and artificial neural networks (ANNs) were performer to build the quantitative prediction models that allowed the quantification of the antioxidant capacity of the tested wines

  17. Initial Operative Experience and Short-term Hearing Preservation Results With a Mid-scala Cochlear Implant Electrode Array.

    Science.gov (United States)

    Svrakic, Maja; Roland, J Thomas; McMenomey, Sean O; Svirsky, Mario A

    2016-12-01

    To describe our initial operative experience and hearing preservation results with the Advanced Bionics (AB) Mid Scala Electrode (MSE). Retrospective review. Tertiary referral center. Sixty-three MSE implants in pediatric and adult patients were compared with age- and sex-matched 1j electrode implants from the same manufacturer. All patients were severe to profoundly deaf. Cochlear implantation with either the AB 1j electrode or the AB MSE. The MSE and 1j electrodes were compared in their angular depth of insertion and pre to postoperative change in hearing thresholds. Hearing preservation was analyzed as a function of angular depth of insertion. Secondary outcome measures included operative time, incidence of abnormal intraoperative impedance and telemetry values, and incidence of postsurgical complications. Depth of insertion was similar for both electrodes, but was more consistent for the MSE array and more variable for the 1j array. Patients with MSE electrodes had better hearing preservation. Thresholds shifts at four audiometric frequencies ranging from 250 to 2000 Hz were 10, 7, 2, and 6 dB smaller for the MSE electrode than for the 1j (p < 0.05). Hearing preservation at low frequencies was worse with deeper insertion, regardless of array. Secondary outcome measures were similar for both electrodes. The MSE electrode resulted in more consistent insertion depth and somewhat better hearing preservation than the 1j electrode. Differences in other surgical outcome measures were small or unlikely to have a meaningful effect.

  18. Hierarchical Mesoporous Zinc-Nickel-Cobalt Ternary Oxide Nanowire Arrays on Nickel Foam as High-Performance Electrodes for Supercapacitors.

    Science.gov (United States)

    Wu, Chun; Cai, Junjie; Zhang, Qiaobao; Zhou, Xiang; Zhu, Ying; Shen, Pei Kang; Zhang, Kaili

    2015-12-09

    Nickel foam supported hierarchical mesoporous Zn-Ni-Co ternary oxide (ZNCO) nanowire arrays are synthesized by a simple two-step approach including a hydrothermal method and subsequent calcination process and directly utilized for supercapacitive investigation for the first time. The nickel foam supported hierarchical mesoporous ZNCO nanowire arrays possess an ultrahigh specific capacitance value of 2481.8 F g(-1) at 1 A g(-1) and excellent rate capability of about 91.9% capacitance retention at 5 A g(-1). More importantly, an asymmetric supercapacitor with a high energy density (35.6 Wh kg(-1)) and remarkable cycle stability performance (94% capacitance retention over 3000 cycles) is assembled successfully by employing the ZNCO electrode as positive electrode and activated carbon as negative electrode. The remarkable electrochemical behaviors demonstrate that the nickel foam supported hierarchical mesoporous ZNCO nanowire array electrodes are highly desirable for application as advanced supercapacitor electrodes.

  19. Geographic tongue

    Science.gov (United States)

    ... be due to irritation from hot or spicy foods, or alcohol. The condition appears to be less common in ... Avoid irritating your tongue with hot or spicy food or alcohol if you are prone to this condition. Alternative ...

  20. Tissue Damage, Temperature, and pH Induced by Different Electrode Arrays on Potato Pieces (Solanum tuberosum L.

    Directory of Open Access Journals (Sweden)

    Maraelys Morales González

    2018-04-01

    Full Text Available One of the most challenging problems of electrochemical therapy is the design and selection of suitable electrode array for cancer. The aim is to determine how two-dimensional spatial patterns of tissue damage, temperature, and pH induced in pieces of potato (Solanum tuberosum L., var. Mondial depend on electrode array with circular, elliptical, parabolic, and hyperbolic shape. The results show the similarity between the shapes of spatial patterns of tissue damage and electric field intensity, which, like temperature and pH take the same shape of electrode array. The adequate selection of suitable electrodes array requires an integrated analysis that involves, in a unified way, relevant information about the electrochemical process, which is essential to perform more efficiently way the therapeutic planning and the personalized therapy for patients with a cancerous tumor.

  1. Amperometric Morphine Detection Using Pt-Co Alloy Nanowire Array-modified Electrode

    International Nuclear Information System (INIS)

    Tao, Manlan; Xu, Feng; Li, Yueting; Xu, Quanqing; Chang, Yanbing; Yang, Yunhui; Wu, Zaisheng

    2010-01-01

    Pt-Co alloy nanowire array was directly synthesized by electrochemical deposition with polycarbonate template at -1.0V and subsequent chemical etching of the template. The use of Pt-Co alloy nanowire array-modified electrode (Pt- Co NAE) for the determination of morphine (MO) is described. The morphology of the Pt-Co alloy nanowire array has been investigated by scanning electron microscopy (SEM) and energy disperse X-ray spectroscopy (EDS) analysis), respectively. The resulting Pt-Co NAE offered a linear amperometric response for morphine ranging from 2.35 x 10 -5 to 2.39 x 10 -3 M with a detection limit of 7.83 x 10 -6 M at optimum conditions. This sensor displayed high sensitivity and long-term stability

  2. Oriented Polyaniline Nanowire Arrays Grown on Dendrimer (PAMAM) Functionalized Multiwalled Carbon Nanotubes as Supercapacitor Electrode Materials.

    Science.gov (United States)

    Jin, Lin; Jiang, Yu; Zhang, Mengjie; Li, Honglong; Xiao, Linghan; Li, Ming; Ao, Yuhui

    2018-04-19

    At present, PANI/MWNT composites have been paid more attention as promising electrode materials in supercapacitors. Yet some shortcomings still limit the widely application of PANI/MWNT electrolytes. In this work, in order to improve capacitance ability and long-term stability of electrode, a multi-amino dendrimer (PAMAM) had been covalently linked onto multi-walled carbon nanotubes (MWNT) as a bridge to facilitating covalent graft of polyaniline (PANI), affording P-MWNT/PANI electrode composites for supercapacitor. Surprisingly, ordered arrays of PANI nanowires on MWNT (setaria-like morphology) had been observed by scanning electron microscopy (SEM). Electrochemical properties of P-MWNT/PANI electrode had been characterized by cyclic voltammetry (CV) and galvanostatic charge-discharge technique. The specific capacitance and long cycle life of P-MWNT-PANI electrode material were both much higher than MWNT/PANI. These interesting results indicate that multi-amino dendrimer, PAMAM, covalently linked on MWNT provides more reaction sites for in-situ polymerization of ordered PANI, which could efficiently shorten the ion diffusion length in electrolytes and lead to making fully use of conducting materials.

  3. Real-time monitoring of cellular dynamics using a microfluidic cell culture system with integrated electrode array and potentiostat

    DEFF Research Database (Denmark)

    Zor, Kinga; Vergani, M.; Heiskanen, Arto

    2011-01-01

    A versatile microfluidic, multichamber cell culture and analysis system with an integrated electrode array and potentiostat suitable for electrochemical detection and microscopic imaging is presented in this paper. The system, which allows on-line electrode cleaning and modification, was develope...

  4. Analytical Formulation of the Electric Field Induced by Electrode Arrays: Towards Automated Dielectrophoretic Cell Sorting

    Directory of Open Access Journals (Sweden)

    Vladimir Gauthier

    2017-08-01

    Full Text Available Dielectrophoresis is defined as the motion of an electrically polarisable particle in a non-uniform electric field. Current dielectrophoretic devices enabling sorting of cells are mostly controlled in open-loop applying a predefined voltage on micro-electrodes. Closed-loop control of these devices would enable to get advanced functionalities and also more robust behavior. Currently, the numerical models of dielectrophoretic force are too complex to be used in real-time closed-loop control. The aim of this paper is to propose a new type of models usable in this framework. We propose an analytical model of the electric field based on Fourier series to compute the dielectrophoretic force produced by parallel electrode arrays. Indeed, this method provides an analytical expression of the electric potential which decouples the geometrical factors (parameter of our system, the voltages applied on electrodes (input of our system, and the position of the cells (output of our system. Considering the Newton laws on each cell, it enables to generate easily a dynamic model of the cell positions (output function of the voltages on electrodes (input. This dynamic model of our system is required to design the future closed-loop control law. The predicted dielectrophoretic forces are compared to a numerical simulation based on finite element model using COMSOL software. The model presented in this paper enables to compute the dielectrophoretic force applied to a cell by an electrode array in a few tenths of milliseconds. This model could be consequently used in future works for closed-loop control of dielectrophoretic devices.

  5. Non-invasive method for selection of electrodes and stimulus parameters for FES applications with intrafascicular arrays

    Science.gov (United States)

    Dowden, B. R.; Frankel, M. A.; Normann, R. A.; Clark, G. A.

    2012-02-01

    High-channel-count intrafascicular electrode arrays provide comprehensive and selective access to the peripheral nervous system. One practical difficulty in using several electrode arrays to evoke coordinated movements in paralyzed limbs is the identification of the appropriate stimulation channels and stimulus parameters to evoke desired movements. Here we present the use of a six degree-of-freedom load cell placed under the foot of a feline to characterize the muscle activation produced by three 100-electrode Utah Slanted Electrode Arrays (USEAs) implanted into the femoral nerves, sciatic nerves, and muscular branches of the sciatic nerves of three cats. Intramuscular stimulation was used to identify the endpoint force directions produced by 15 muscles of the hind limb, and these directions were used to classify the forces produced by each intrafascicular USEA electrode as flexion or extension. For 451 USEA electrodes, stimulus intensities for threshold and saturation muscle forces were identified, and the 3D direction and linearity of the force recruitment curves were determined. Further, motor unit excitation independence for 198 electrode pairs was measured using the refractory technique. This study demonstrates the utility of 3D endpoint force monitoring as a simple and non-invasive metric for characterizing the muscle-activation properties of hundreds of implanted peripheral nerve electrodes, allowing for electrode and parameter selection for neuroprosthetic applications.

  6. Vertically Aligned Carbon Nanotube Arrays as Efficient Supports for Faradaic Capacitive Electrodes

    Science.gov (United States)

    Oguntoye, Moses; Holleran, Mary-Kate; Roberts, Katherine; Pesika, Noshir

    Supercapacitors are notable for their ability to deliver energy at higher power (compared to batteries) and store energy at higher density (compared to capacitors) as well as exhibit a long cycle life. In our efforts to further the development of supercapacitors, our focus is on using vertically aligned carbon nanotubes (VACNT) as supports for faradaic capacitive electrode materials. The objective is to develop electrodes functioning in an inexpensive aqueous environment with small potential windows, that store energy at a higher density than carbon materials alone. We describe the different approaches explored to overcome the challenges of non-uniform deposition, poor wetting and array collapse. Materials that are electrochemically anchored to VACNT supports include NiCo2O4, VOx, Fe2O3 and Co-Mn mixed oxides. In each case, the specific capacitance obtained using the VACNT arrays as supports is significantly more than that obtained by direct deposition onto current collectors or by using VACNT alone. The ease of VACNT growth and the degree of coating control achievable using electrodeposition means there is much potential in exploring them as supports for capacitive electrode materials.

  7. 3D Self-Supported Nanoarchitectured Arrays Electrodes for Lithium-Ion Batteries

    Directory of Open Access Journals (Sweden)

    Xin Chen

    2012-01-01

    Full Text Available Three-dimensional self-supported nanoarchitectured arrays electrodes (3DSNAEs consisting of a direct growth of nanoarchitectured arrays on the conductive current collector, including homogeneous and heterogeneous nanoarchitectured arrays structures, have been currently studied as the most promising electrodes owing to their synergies resulting from the multistructure hybrid and integrating heterocomponents to address the requirements (high energy and power density of superperformance lithium ion batteries (LIBs applied in portable electronic consumer devices, electric vehicles, large-scale electricity storage, and so on. In the paper, recent advances in the strategies for the fabrication, selection of the different current collector substrates, and structural configuration of 3DSNAEs with different cathode and anode materials are investigated in detail. The intrinsic relationship of the unique structural characters, the conductive substrates, and electrochemical kinetic properties of 3DSNAEs is minutely analyzed. Finally, the future design trends and directions of 3DSNAEs are highlighted, which may open a new avenue of developing ideal multifunctional 3DSNAEs for further advanced LIBs.

  8. Cochlear implantation in Mondini's deformity: could the straight electrode array with length of 31 mm be fully inserted?

    Science.gov (United States)

    Sun, Jia-Qiang; Sun, Jing-Wu; Hou, Xiao-Yan

    2017-07-01

    The straight electrode array with length of 31 mm can be fully inserted using round window insertion in cochlear implantation with Mondini's deformity. It is a safe and effective process, but also a challenging task of the full implantation in children with Mondini's deformity. The aim of this study is to discuss whether the straight electrode array with a length of 31 mm could be fully inserted in cochlear implantation with Mondini's deformity. A chart review of 30 patients undergoing cochlear implantation with Mondini's deformity using the electrode array with length of 31 mm was undertaken from January 2012 and December 2015 in Anhui Provincial Hospital. Full insertion of the straight electrode array with length of 31 mm were performed successfully in all patients with Mondini's deformity using round window insertion. Resistance was not encountered while introducing the electrodes. Ten of 30 patients had cerebrospinal fluid drainage during cochlear implantation. Cerebrospinal fluid drainage was controlled with small pieces of temporalis fascia packing round window in all patients. Intra-operative neural response telemetry was performed in all patients, and results were good. The result of X-ray showed proper placement of the cochlear implant electrode array. During surgery, no patients had experienced any immediate or delayed post-operative complications such as wound infection, intracranial complication, extrusion, or migration of the implant during an average follow-up period of 6-36 months.

  9. The Effect of Scala Tympani Morphology on Basilar Membrane Contact With a Straight Electrode Array: A Human Temporal Bone Study.

    Science.gov (United States)

    Verberne, Juul; Risi, Frank; Campbell, Luke; Chambers, Scott; O'Leary, Stephen

    2017-01-01

    Scala tympani morphology influences the insertion dynamics and intra-scalar position of straight electrode arrays. Hearing preservation is the goal of cochlear implantation with current thin straight electrode arrays. These hug the lateral wall, facilitating full, atraumatic insertions. However, most studies still report some postoperative hearing loss. This study explores the influence of scala tympani morphology on array position relative to the basilar membrane and its possible contribution to postoperative hearing loss. Twenty-six fresh-frozen human temporal bones implanted with a straight electrode array were three-dimensionally reconstructed from micro-photographic histological sections. Insertion depth and the proximity between the array and basilar membrane were recorded. Lateral wall shape was quantified as a curvature ratio. Insertion depths ranged from 233 to 470 degrees. The mean first point of contact between the array and basilar membrane was 185 degrees; arrays tended to remain in contact with the membrane after first contacting it. Eighty-nine and 93% of arrays that reached the upper basal (>240-360 degrees) and second (>360-720 degrees) turns respectively contacted the basilar membrane in these regions. Scalar wall curvature ratio decreased significantly (the wall became steeper) from the basal to second turns. This shift correlated with a reduced distance between the array and basilar membrane. Scala tympani morphology influences the insertion dynamics and intra-scalar position of a straight electrode array. In addition to gross trauma of cochlear structures, contact between the array and basilar membrane and how this impacts membrane function should be considered in hearing preservation cases.

  10. An electrocorticographic electrode array for simultaneous recording from medial, lateral, and intrasulcal surface of the cortex in macaque monkeys.

    Science.gov (United States)

    Fukushima, Makoto; Saunders, Richard C; Mullarkey, Matthew; Doyle, Alexandra M; Mishkin, Mortimer; Fujii, Naotaka

    2014-08-15

    Electrocorticography (ECoG) permits recording electrical field potentials with high spatiotemporal resolution over a large part of the cerebral cortex. Application of chronically implanted ECoG arrays in animal models provides an opportunity to investigate global spatiotemporal neural patterns and functional connectivity systematically under various experimental conditions. Although ECoG is conventionally used to cover the gyral cortical surface, recent studies have shown the feasibility of intrasulcal ECoG recordings in macaque monkeys. Here we developed a new ECoG array to record neural activity simultaneously from much of the medial and lateral cortical surface of a single hemisphere, together with the supratemporal plane (STP) of the lateral sulcus in macaque monkeys. The ECoG array consisted of 256 electrodes for bipolar recording at 128 sites. We successfully implanted the ECoG array in the left hemisphere of three rhesus monkeys. The electrodes in the auditory and visual cortex detected robust event related potentials to auditory and visual stimuli, respectively. Bipolar recording from adjacent electrode pairs effectively eliminated chewing artifacts evident in monopolar recording, demonstrating the advantage of using the ECoG array under conditions that generate significant movement artifacts. Compared with bipolar ECoG arrays previously developed for macaque monkeys, this array significantly expands the number of cortical target areas in gyral and intralsulcal cortex. This new ECoG array provides an opportunity to investigate global network interactions among gyral and intrasulcal cortical areas. Published by Elsevier B.V.

  11. Curved Microneedle Array-Based sEMG Electrode for Robust Long-Term Measurements and High Selectivity

    Directory of Open Access Journals (Sweden)

    Minjae Kim

    2015-07-01

    Full Text Available Surface electromyography is widely used in many fields to infer human intention. However, conventional electrodes are not appropriate for long-term measurements and are easily influenced by the environment, so the range of applications of sEMG is limited. In this paper, we propose a flexible band-integrated, curved microneedle array electrode for robust long-term measurements, high selectivity, and easy applicability. Signal quality, in terms of long-term usability and sensitivity to perspiration, was investigated. Its motion-discriminating performance was also evaluated. The results show that the proposed electrode is robust to perspiration and can maintain a high-quality measuring ability for over 8 h. The proposed electrode also has high selectivity for motion compared with a commercial wet electrode and dry electrode.

  12. Fabrication of Composite Microneedle Array Electrode for Temperature and Bio-Signal Monitoring.

    Science.gov (United States)

    Sun, Yiwei; Ren, Lei; Jiang, Lelun; Tang, Yong; Liu, Bin

    2018-04-13

    Body temperature and bio-signals are important health indicators that reflect the human health condition. However, monitoring these indexes is inconvenient and time-consuming, requires various instruments, and needs professional skill. In this study, a composite microneedle array electrode (CMAE) was designed and fabricated. It simultaneously detects body temperature and bio-signals. The CMAE consists of a 6 × 6 microneedles array with a height of 500 μm and a base diameter of 200 μm. Multiple insertion experiments indicate that the CMAE possesses excellent mechanical properties. The CMAE can pierce porcine skin 100 times without breaking or bending. A linear calibration relationship between temperature and voltage are experimentally obtained. Armpit temperature (35.8 °C) and forearm temperature (35.3 °C) are detected with the CMAE, and the measurements agree well with the data acquired with a clinical thermometer. Bio-signals including EII, ECG, and EMG are recorded and compared with those obtained by a commercial Ag/AgCl electrode. The CMAE continuously monitors bio-signals and is more convenient to apply because it does not require skin preparation and gel usage. The CMAE exhibits good potential for continuous and repetitive monitoring of body temperature and bio-signals.

  13. Fabrication of Composite Microneedle Array Electrode for Temperature and Bio-Signal Monitoring

    Directory of Open Access Journals (Sweden)

    Yiwei Sun

    2018-04-01

    Full Text Available Body temperature and bio-signals are important health indicators that reflect the human health condition. However, monitoring these indexes is inconvenient and time-consuming, requires various instruments, and needs professional skill. In this study, a composite microneedle array electrode (CMAE was designed and fabricated. It simultaneously detects body temperature and bio-signals. The CMAE consists of a 6 × 6 microneedles array with a height of 500 μm and a base diameter of 200 μm. Multiple insertion experiments indicate that the CMAE possesses excellent mechanical properties. The CMAE can pierce porcine skin 100 times without breaking or bending. A linear calibration relationship between temperature and voltage are experimentally obtained. Armpit temperature (35.8 °C and forearm temperature (35.3 °C are detected with the CMAE, and the measurements agree well with the data acquired with a clinical thermometer. Bio-signals including EII, ECG, and EMG are recorded and compared with those obtained by a commercial Ag/AgCl electrode. The CMAE continuously monitors bio-signals and is more convenient to apply because it does not require skin preparation and gel usage. The CMAE exhibits good potential for continuous and repetitive monitoring of body temperature and bio-signals.

  14. A novel high electrode count spike recording array using an 81,920 pixel transimpedance amplifier-based imaging chip.

    Science.gov (United States)

    Johnson, Lee J; Cohen, Ethan; Ilg, Doug; Klein, Richard; Skeath, Perry; Scribner, Dean A

    2012-04-15

    Microelectrode recording arrays of 60-100 electrodes are commonly used to record neuronal biopotentials, and these have aided our understanding of brain function, development and pathology. However, higher density microelectrode recording arrays of larger area are needed to study neuronal function over broader brain regions such as in cerebral cortex or hippocampal slices. Here, we present a novel design of a high electrode count picocurrent imaging array (PIA), based on an 81,920 pixel Indigo ISC9809 readout integrated circuit camera chip. While originally developed for interfacing to infrared photodetector arrays, we have adapted the chip for neuron recording by bonding it to microwire glass resulting in an array with an inter-electrode pixel spacing of 30 μm. In a high density electrode array, the ability to selectively record neural regions at high speed and with good signal to noise ratio are both functionally important. A critical feature of our PIA is that each pixel contains a dedicated low noise transimpedance amplifier (∼0.32 pA rms) which allows recording high signal to noise ratio biocurrents comparable to single electrode voltage amplifier recordings. Using selective sampling of 256 pixel subarray regions, we recorded the extracellular biocurrents of rabbit retinal ganglion cell spikes at sampling rates up to 7.2 kHz. Full array local electroretinogram currents could also be recorded at frame rates up to 100 Hz. A PIA with a full complement of 4 readout circuits would span 1cm and could acquire simultaneous data from selected regions of 1024 electrodes at sampling rates up to 9.3 kHz. Published by Elsevier B.V.

  15. Initial Operative Experience and Short Term Hearing Preservation Results with a Mid-Scala Cochlear Implant Electrode Array

    Science.gov (United States)

    Svrakic, Maja; Roland, J. Thomas; McMenomey, Sean O.; Svirsky, Mario A.

    2016-01-01

    OBJECTIVE To describe our initial operative experience and hearing preservation results with the Advanced Bionics (AB) Mid Scala Electrode (MSE) STUDY DESIGN Retrospective review. SETTING Tertiary referral center. PATIENTS Sixty-three MSE implants in pediatric and adult patients were compared to age- and gender-matched 1j electrode implants from the same manufacturer. All patients were severe to profoundly deaf. INTERVENTION Cochlear implantation with either the AB 1j electrode or the AB MSE. MAIN OUTCOME MEASURES The MSE and 1j electrode were compared in their angular depth of insertion (aDOI) and pre- to post-operative change in hearing thresholds. Hearing preservation was analyzed as a function of aDOI. Secondary outcome measures included operative time, incidence of abnormal intraoperative impedance and telemetry values, and incidence of postsurgical complications. RESULTS Depth of insertion was similar for both electrodes, but was more consistent for the MSE array and more variable for the 1j array. Patients with MSE electrodes had better hearing preservation. Thresholds shifts at four audiometric frequencies ranging from 250 to 2,000 Hz were 10 dB, 7 dB, 2 dB and 6 dB smaller for the MSE electrode than for the 1j (p<0.05). Hearing preservation at low frequencies was worse with deeper insertion, regardless of array. Secondary outcome measures were similar for both electrodes. CONCLUSIONS The MSE electrode resulted in more consistent insertion depth and somewhat better hearing preservation than the 1j electrode. Differences in other surgical outcome measures were small or unlikely to have a meaningful effect. PMID:27755356

  16. Scalar localization by cone-beam computed tomography of cochlear implant carriers: a comparative study between straight and periomodiolar precurved electrode arrays.

    Science.gov (United States)

    Boyer, Eric; Karkas, Alexandre; Attye, Arnaud; Lefournier, Virginie; Escude, Bernard; Schmerber, Sebastien

    2015-03-01

    To compare the incidence of dislocation of precurved versus straight flexible cochlear implant electrode arrays using cone-beam computed tomography (CBCT) image analyses. Consecutive nonrandomized case-comparison study. Tertiary referral center. Analyses of patients' CBCT images after cochlear implant surgery. Precurved and straight flexible electrode arrays from two different manufacturers were implanted. A round window insertion was performed in most cases. Two cases necessitated a cochleostomy. The patients' CBCT images were reconstructed in the coronal oblique, sagittal oblique, and axial oblique section. The insertion depth angle and the incidence of dislocation from the scala tympani to the scala vestibuli were determined. The CBCT images and the incidence of dislocation were analyzed in 54 patients (61 electrode arrays). Thirty-one patients were implanted with a precurved perimodiolar electrode array and 30 patients with a straight flexible electrode array. A total of nine (15%) scalar dislocations were observed in both groups. Eight (26%) scalar dislocations were observed in the precurved array group and one (3%) in the straight array group. Dislocation occurred at an insertion depth angle between 170 and 190 degrees in the precurved array group and at approximately 370 degrees in the straight array group. With precurved arrays, dislocation usually occurs in the ascending part of the basal turn of the cochlea. With straight flexible electrode arrays, the incidence of dislocation was lower, and it seems that straight flexible arrays have a higher chance of a confined position within the scala tympani than perimodiolar precurved arrays.

  17. A Multi-Functional Microelectrode Array Featuring 59760 Electrodes, 2048 Electrophysiology Channels, Stimulation, Impedance Measurement and Neurotransmitter Detection Channels.

    Science.gov (United States)

    Dragas, Jelena; Viswam, Vijay; Shadmani, Amir; Chen, Yihui; Bounik, Raziyeh; Stettler, Alexander; Radivojevic, Milos; Geissler, Sydney; Obien, Marie; Müller, Jan; Hierlemann, Andreas

    2017-06-01

    Biological cells are characterized by highly complex phenomena and processes that are, to a great extent, interdependent. To gain detailed insights, devices designed to study cellular phenomena need to enable tracking and manipulation of multiple cell parameters in parallel; they have to provide high signal quality and high spatiotemporal resolution. To this end, we have developed a CMOS-based microelectrode array system that integrates six measurement and stimulation functions, the largest number to date. Moreover, the system features the largest active electrode array area to date (4.48×2.43 mm 2 ) to accommodate 59,760 electrodes, while its power consumption, noise characteristics, and spatial resolution (13.5 μm electrode pitch) are comparable to the best state-of-the-art devices. The system includes: 2,048 action-potential (AP, bandwidth: 300 Hz to 10 kHz) recording units, 32 local-field-potential (LFP, bandwidth: 1 Hz to 300 Hz) recording units, 32 current recording units, 32 impedance measurement units, and 28 neurotransmitter detection units, in addition to the 16 dual-mode voltage-only or current/voltage-controlled stimulation units. The electrode array architecture is based on a switch matrix, which allows for connecting any measurement/stimulation unit to any electrode in the array and for performing different measurement/stimulation functions in parallel.

  18. Behavioral and cellular consequences of high-electrode count Utah Arrays chronically implanted in rat sciatic nerve

    Science.gov (United States)

    Wark, H. A. C.; Mathews, K. S.; Normann, R. A.; Fernandez, E.

    2014-08-01

    Objective. Before peripheral nerve electrodes can be used for the restoration of sensory and motor functions in patients with neurological disorders, the behavioral and histological consequences of these devices must be investigated. These indices of biocompatibility can be defined in terms of desired functional outcomes; for example, a device may be considered for use as a therapeutic intervention if the implanted subject retains functional neurons post-implantation even in the presence of a foreign body response. The consequences of an indwelling device may remain localized to cellular responses at the device-tissue interface, such as fibrotic encapsulation of the device, or they may affect the animal more globally, such as impacting behavioral or sensorimotor functions. The objective of this study was to investigate the overall consequences of implantation of high-electrode count intrafascicular peripheral nerve arrays, High Density Utah Slanted Electrode Arrays (HD-USEAs; 25 electrodes mm-2). Approach. HD-USEAs were implanted in rat sciatic nerves for one and two month periods. We monitored wheel running, noxious sensory paw withdrawal reflexes, footprints, nerve morphology and macrophage presence at the tissue-device interface. In addition, we used a novel approach to contain the arrays in actively behaving animals that consisted of an organic nerve wrap. A total of 500 electrodes were implanted across all ten animals. Main results. The results demonstrated that chronic implantation (⩽8 weeks) of HD-USEAs into peripheral nerves can evoke behavioral deficits that recover over time. Morphology of the nerve distal to the implantation site showed variable signs of nerve fiber degeneration and regeneration. Cytology adjacent to the device-tissue interface also showed a variable response, with some electrodes having many macrophages surrounding the electrodes, while other electrodes had few or no macrophages present. This variability was also seen along the length

  19. Performance assessments of vertically aligned carbon nanotubes multi-electrode arrays using Cath.a-differentiated (CAD) cells

    Science.gov (United States)

    Jeong, Du Won; Jung, Jongjin; Kim, Gook Hwa; Yang, Cheol-Soo; Kim, Ju Jin; Jung, Sang Don; Lee, Jeong-O.

    2015-08-01

    In this work, Cath.a-differentiated (CAD) cells were used in place of primary neuronal cells to assess the performance of vertically aligned carbon nanotubes (VACNTs) multi-electrode arrays (MEA). To fabricate high-performance MEA, VACNTs were directly grown on graphene/Pt electrodes via plasma enhanced chemical deposition technique. Here, graphene served as an intermediate layer lowering contact resistance between VACNTs and Pt electrode. In order to lower the electrode impedance and to enhance the cell adhesion, VACNTs-MEAs were treated with UV-ozone for 20 min. Impedance of VACNTs electrode at 1 kHz frequency exhibits a reasonable value (110 kΩ) for extracellular signal recording, and the signal to noise ratio the is good enough to measure low signal amplitude (15.7). Spontaneous firing events from CAD cells were successfully measured with VACNTs MEAs that were also found to be surprisingly robust toward the biological interactions.

  20. Performance assessments of vertically aligned carbon nanotubes multi-electrode arrays using Cath.a-differentiated (CAD) cells

    International Nuclear Information System (INIS)

    Jeong, Du Won; Jin Kim, Ju; Jung, Jongjin; Yang, Cheol-Soo; Lee, Jeong-O; Hwa Kim, Gook; Don Jung, Sang

    2015-01-01

    In this work, Cath.a-differentiated (CAD) cells were used in place of primary neuronal cells to assess the performance of vertically aligned carbon nanotubes (VACNTs) multi-electrode arrays (MEA). To fabricate high-performance MEA, VACNTs were directly grown on graphene/Pt electrodes via plasma enhanced chemical deposition technique. Here, graphene served as an intermediate layer lowering contact resistance between VACNTs and Pt electrode. In order to lower the electrode impedance and to enhance the cell adhesion, VACNTs-MEAs were treated with UV–ozone for 20 min. Impedance of VACNTs electrode at 1 kHz frequency exhibits a reasonable value (110 kΩ) for extracellular signal recording, and the signal to noise ratio the is good enough to measure low signal amplitude (15.7). Spontaneous firing events from CAD cells were successfully measured with VACNTs MEAs that were also found to be surprisingly robust toward the biological interactions. (paper)

  1. Innervation zones of fasciculating motor units: observations by a linear electrode array.

    Science.gov (United States)

    Jahanmiri-Nezhad, Faezeh; Barkhaus, Paul E; Rymer, William Z; Zhou, Ping

    2015-01-01

    This study examines the innervation zone (IZ) in the biceps brachii muscle in healthy subjects and those with amyotrophic lateral sclerosis (ALS) using a 20-channel linear electromyogram (EMG) electrode array. Raster plots of individual waveform potentials were studied to estimate the motor unit IZ. While this work mainly focused on fasciculation potentials (FPs), a limited number of motor unit potentials (MUPs) from voluntary activity of 12 healthy and seven ALS subjects were also examined. Abnormal propagation of MUPs and scattered IZs were observed in fasciculating units, compared with voluntarily activated MUPs in healthy and ALS subjects. These findings can be related to muscle fiber reinnervation following motor neuron degeneration in ALS and the different origin sites of FPs compared with voluntary MUPs.

  2. Fabrication of PANI/C-TiO2 Composite Nanotube Arrays Electrode for Supercapacitor

    Directory of Open Access Journals (Sweden)

    Chengcheng Zhang

    2015-01-01

    Full Text Available Polyaniline/carbon doped TiO2 composite nanotube arrays (PANI/C-TiO2 NTAs have been prepared successfully by electrodepositing PANI in C-TiO2 NTAs which were prepared by directly annealing the as-anodized TiO2 NTAs under Ar atmosphere. The organic residual in the TiO2 NTAs during the process of anodization acts as carbon source and is carbonized in Ar atmosphere to manufacture the C-TiO2 NTAs. The specific capacitance of the PANI/C-TiO2 electrode is 120.8 mF cm−2 at a current density of 0.1 mA cm−2 and remains 104.3 mF cm−2 at a current density of 2 mA cm−2 with the calculated rate performance of 86.3%. After 5000 times of charge-discharge cycling at a current density of 0.2 mA cm−2, the specific capacitance retains 88.7% compared to the first cycle. All these outstanding performances of the as-prepared PANI/C-TiO2 NTAs indicate it will be a promising electrode for supercapacitor.

  3. Specific detection of oxytetracycline using DNA aptamer-immobilized interdigitated array electrode chip

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeon Seok; Niazi, Javed H [School of Life Sciences and Biotechnology, Korea University, Anam-dong, Seongbuk-gu, Seoul 136-701 (Korea, Republic of); Gu, Man Bock [School of Life Sciences and Biotechnology, Korea University, Anam-dong, Seongbuk-gu, Seoul 136-701 (Korea, Republic of)], E-mail: mbgu@korea.ac.kr

    2009-02-23

    An electrochemical sensing system for oxytetracycline (OTC) detection was developed using ssDNA aptamer immobilized on gold interdigitated array (IDA) electrode chip. A highly specific ssDNA aptamer that bind to OTC with high affinity was employed to discriminate other tetracyclines (TCs), such as doxycycline (DOX) and tetracycline (TET). The immobilized thiol-modified aptamer on gold electrode chip served as a biorecognition element for the target molecules and the electrochemical signals generated from interactions between the aptamers and the target molecules was evaluated by cyclic voltammetry (CV) and square wave voltammetry (SWV). The current decrease due to the interference of bound OTC, DOX or TET was analyzed with the electron flow produced by a redox reaction between ferro- and ferricyanide. The specificity of developed EC-biosensor for OTC was highly distinguishable from the structurally similar antibiotics (DOX and TET). The dynamic range was determined to be 1-100 nM of OTC concentration in semi-logarithmic coordinates.

  4. Specific detection of oxytetracycline using DNA aptamer-immobilized interdigitated array electrode chip

    International Nuclear Information System (INIS)

    Kim, Yeon Seok; Niazi, Javed H.; Gu, Man Bock

    2009-01-01

    An electrochemical sensing system for oxytetracycline (OTC) detection was developed using ssDNA aptamer immobilized on gold interdigitated array (IDA) electrode chip. A highly specific ssDNA aptamer that bind to OTC with high affinity was employed to discriminate other tetracyclines (TCs), such as doxycycline (DOX) and tetracycline (TET). The immobilized thiol-modified aptamer on gold electrode chip served as a biorecognition element for the target molecules and the electrochemical signals generated from interactions between the aptamers and the target molecules was evaluated by cyclic voltammetry (CV) and square wave voltammetry (SWV). The current decrease due to the interference of bound OTC, DOX or TET was analyzed with the electron flow produced by a redox reaction between ferro- and ferricyanide. The specificity of developed EC-biosensor for OTC was highly distinguishable from the structurally similar antibiotics (DOX and TET). The dynamic range was determined to be 1-100 nM of OTC concentration in semi-logarithmic coordinates

  5. Test results of CPT-deployed vertical electrode arrays at the DOE Hanford Site

    International Nuclear Information System (INIS)

    Narbutovskih, S.M.; Daily, W.; Ramirez, A.L.; Morey, R.M.

    1997-01-01

    Field studies were conducted at the DOE Hanford Site to test cone penetrometer installation of vertical electrode arrays (VEA) for use with Electrical Resistivity Tomography (ERT). Most VEA installation methods in current use are not economic for environmental applications. The cone penetrometer technology (CPT) can provide an economic and relatively non-intrusive installation method. However, a VEA with deployable and properly functioning electrodes was required. Results of the design, installation and testing of CPT VEAs are reported in this paper. Several designs were developed and bench tested for use with the CPT. After initial field installation studies, one design was chosen for further testing at the DOE Hanford Site. Four VEAs were each pushed to 100 feet in 4 days. To test the CPT VEAs, an infiltration experiment was conducted with cross VEA tomographic data collected for three vertical planes. These data were processed using the electrical resistivity tomography code developed by Lawrence Livermore National Laboratory (LLNL). Tomographic images for each vertical plane tracked the subsurface resistivity changes associated with the migrating fluid. It is concluded from these test results that the CPT is a viable method for installing VEAs. The VEAs were rapidly and economically installed to the maximum depth required, data of adequate quality were obtained and tomographic images from the infiltration experiment verified that the CPT VEAs provide viable ERT data

  6. Biomimetic hydrogels for biosensor implant biocompatibility: electrochemical characterization using micro-disc electrode arrays (MDEAs).

    Science.gov (United States)

    Justin, Gusphyl; Finley, Stephen; Abdur Rahman, Abdur Rub; Guiseppi-Elie, Anthony

    2009-02-01

    Our interest is in the development of engineered microdevices for continuous remote monitoring of intramuscular lactate, glucose, pH and temperature during post-traumatic hemorrhaging. Two important design considerations in the development of such devices for in vivo diagnostics are discussed; the utility of micro-disc electrode arrays (MDEAs) for electrochemical biosensing and the application of biomimetic, bioactive poly(HEMA)-based hydrogel composites for implant biocompatibility. A poly(HEMA)-based hydrogel membrane containing polyethylene glycol (PEG) was UV cross-linked with tetraethyleneglycol diacrylate following application to MDEAs (50 mum discs) and to 250 mum diameter gold electrodes within 8-well culture ware. Cyclic voltammetry (CV) of the MDEAs revealed a reduction in the apparent diffusion coefficient of ferrocenemonocarboxylic acid (FcCO(2)H), from 6.68 x 10(-5) to 6.74 x 10(-6) cm(2)/s for the uncoated and 6 mum thick hydrogel coated devices, respectively. Single frequency (4 kHz) temporal impedance measurements of the hydrogels in the 8-well culture ware showed a reversible 5% change in the absolute impedance of the hydrogels when exposed to a pH change between 6.1 to 7.2 and a 20% drop between pH 6.1 and 8.8.

  7. In vitro extracellular recording and stimulation performance of nanoporous gold-modified multi-electrode arrays

    Science.gov (United States)

    Kim, Yong Hee; Kim, Gook Hwa; Kim, Ah Young; Han, Young Hwan; Chung, Myung-Ae; Jung, Sang-Don

    2015-12-01

    Objective. Nanoporous gold (Au) structures can reduce the impedance and enhance the charge injection capability of multi-electrode arrays (MEAs) used for interfacing neuronal networks. Even though there are various nanoporous Au preparation techniques, fabrication of MEA based on low-cost electro-codeposition of Ag:Au has not been performed. In this work, we have modified a Au MEA via the electro-codeposition of Ag:Au alloy, followed by the chemical etching of Ag, and report on the in vitro extracellular recording and stimulation performance of the nanoporous Au-modified MEA. Approach. Ag:Au alloy was electro-codeposited on a bilayer lift-off resist sputter-deposition passivated Au MEA followed by chemical etching of Ag to form a porous Au structure. Main results. The porous Au structure was analyzed by scanning electron microscopy and tunneling electron microscopy and found to have an interconnected nanoporous Au structure. The impedance value of the nanoporous Au-modified MEA is 15.4 ± 0.55 kΩ at 1 kHz, accompanied by the base noise V rms of 2.4 ± 0.3 μV. The charge injection limit of the nanoporous Au-modified electrode estimated from voltage transient measurement is approximately 1 mC cm-2, which is comparable to roughened platinum and carbon nanotube electrodes. The charge injection capability of the nanoporous Au-modified MEA was confirmed by observing stimulus-induced spikes at above 0.2 V. The nanoporous Au-modified MEA showed mechanical durability upon ultrasonic treatment for up to an hour. Significance. Electro-codeposition of Ag:Au alloy combined with chemical etching Ag is a low-cost process for fabricating nanoporous Au-modified MEA suitable for establishing the stimulus-response relationship of cultured neuronal networks.

  8. In vitro extracellular recording and stimulation performance of nanoporous gold-modified multi-electrode arrays.

    Science.gov (United States)

    Kim, Yong Hee; Kim, Gook Hwa; Kim, Ah Young; Han, Young Hwan; Chung, Myung-Ae; Jung, Sang-Don

    2015-12-01

    Nanoporous gold (Au) structures can reduce the impedance and enhance the charge injection capability of multi-electrode arrays (MEAs) used for interfacing neuronal networks. Even though there are various nanoporous Au preparation techniques, fabrication of MEA based on low-cost electro-codeposition of Ag:Au has not been performed. In this work, we have modified a Au MEA via the electro-codeposition of Ag:Au alloy, followed by the chemical etching of Ag, and report on the in vitro extracellular recording and stimulation performance of the nanoporous Au-modified MEA. Ag:Au alloy was electro-codeposited on a bilayer lift-off resist sputter-deposition passivated Au MEA followed by chemical etching of Ag to form a porous Au structure. The porous Au structure was analyzed by scanning electron microscopy and tunneling electron microscopy and found to have an interconnected nanoporous Au structure. The impedance value of the nanoporous Au-modified MEA is 15.4 ± 0.55 kΩ at 1 kHz, accompanied by the base noise V rms of 2.4 ± 0.3 μV. The charge injection limit of the nanoporous Au-modified electrode estimated from voltage transient measurement is approximately 1 mC cm(-2), which is comparable to roughened platinum and carbon nanotube electrodes. The charge injection capability of the nanoporous Au-modified MEA was confirmed by observing stimulus-induced spikes at above 0.2 V. The nanoporous Au-modified MEA showed mechanical durability upon ultrasonic treatment for up to an hour. Electro-codeposition of Ag:Au alloy combined with chemical etching Ag is a low-cost process for fabricating nanoporous Au-modified MEA suitable for establishing the stimulus-response relationship of cultured neuronal networks.

  9. Facile synthesis of ultrathin manganese dioxide nanosheets arrays on nickel foam as advanced binder-free supercapacitor electrodes

    KAUST Repository

    Huang, Ming

    2015-03-01

    © 2014 Elsevier B.V. Ultrathin MnO2 nanosheets arrays on Ni foam have been fabricated by a facile hydrothermal approach and further investigated as the binder-free electrode for high-performance supercapacitors. This unique well-designed binder-free electrode exhibits a high specific capacitance (595.2 F g-1 at a current density of 0.5 A g-1), good rate capability (64.1% retention), and excellent cycling stability (89% capacitance retention after 3000 cycles). Moreover, an asymmetric supercapacitor is constructed using the as-prepared MnO2 nanosheets arrays as the positive electrode and activated microwave exfoliated graphite oxide (MEGO) as the negative electrode. The optimized asymmetric supercapacitor displays excellent electrochemical performance with an energy density of 25.8 Wh kg-1 and a maximum power density of 223.2 kW kg-1. These impressive performances suggest that the MnO2 nanosheet array is a promising electrode material for supercapacitors.

  10. Monitoring of beer fermentation based on hybrid electronic tongue.

    Science.gov (United States)

    Kutyła-Olesiuk, Anna; Zaborowski, Michał; Prokaryn, Piotr; Ciosek, Patrycja

    2012-10-01

    Monitoring of biotechnological processes, including fermentation is extremely important because of the rapidly occurring changes in the composition of the samples during the production. In the case of beer, the analysis of physicochemical parameters allows for the determination of the stage of fermentation process and the control of its possible perturbations. As a tool to control the beer production process a sensor array can be used, composed of potentiometric and voltammetric sensors (so-called hybrid Electronic Tongue, h-ET). The aim of this study is to apply electronic tongue system to distinguish samples obtained during alcoholic fermentation. The samples originate from batch of homemade beer fermentation and from two stages of the process: fermentation reaction and maturation of beer. The applied sensor array consists of 10 miniaturized ion-selective electrodes (potentiometric ET) and silicon based 3-electrode voltammetric transducers (voltammetric ET). The obtained results were processed using Partial Least Squares (PLS) and Partial Least Squares-Discriminant Analysis (PLS-DA). For potentiometric data, voltammetric data, and combined potentiometric and voltammetric data, comparison of the classification ability was conducted based on Root Mean Squared Error (RMSE), sensitivity, specificity, and coefficient F calculation. It is shown, that in the contrast to the separately used techniques, the developed hybrid system allowed for a better characterization of the beer samples. Data fusion in hybrid ET enables to obtain better results both in qualitative analysis (RMSE, specificity, sensitivity) and in quantitative analysis (RMSE, R(2), a, b). Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Linear distributed source modeling of local field potentials recorded with intra-cortical electrode arrays.

    Directory of Open Access Journals (Sweden)

    Rikkert Hindriks

    Full Text Available Planar intra-cortical electrode (Utah arrays provide a unique window into the spatial organization of cortical activity. Reconstruction of the current source density (CSD underlying such recordings, however, requires "inverting" Poisson's equation. For inter-laminar recordings, this is commonly done by the CSD method, which consists in taking the second-order spatial derivative of the recorded local field potentials (LFPs. Although the CSD method has been tremendously successful in mapping the current generators underlying inter-laminar LFPs, its application to planar recordings is more challenging. While for inter-laminar recordings the CSD method seems reasonably robust against violations of its assumptions, is it unclear as to what extent this holds for planar recordings. One of the objectives of this study is to characterize the conditions under which the CSD method can be successfully applied to Utah array data. Using forward modeling, we find that for spatially coherent CSDs, the CSD method yields inaccurate reconstructions due to volume-conducted contamination from currents in deeper cortical layers. An alternative approach is to "invert" a constructed forward model. The advantage of this approach is that any a priori knowledge about the geometrical and electrical properties of the tissue can be taken into account. Although several inverse methods have been proposed for LFP data, the applicability of existing electroencephalographic (EEG and magnetoencephalographic (MEG inverse methods to LFP data is largely unexplored. Another objective of our study therefore, is to assess the applicability of the most commonly used EEG/MEG inverse methods to Utah array data. Our main conclusion is that these inverse methods provide more accurate CSD reconstructions than the CSD method. We illustrate the inverse methods using event-related potentials recorded from primary visual cortex of a macaque monkey during a motion discrimination task.

  12. Electrochemical properties of high-power supercapacitors using ordered NiO coated Si nanowire array electrodes

    Science.gov (United States)

    Lu, Fang; Qiu, Mengchun; Qi, Xiang; Yang, Liwen; Yin, Jinjie; Hao, Guolin; Feng, Xiang; Li, Jun; Zhong, Jianxin

    2011-08-01

    Highly ordered NiO coated Si nanowire arrays are fabricated as electrode materials for electrochemical supercapacitors (ES) via depositing Ni on electroless-etched Si nanowires and subsequently annealing. The electrochemical tests reveal that the constructed electrode has superior electrical conductibility and more active sites per unit area for chemical reaction processes, thereby possessing good cycle stability, high specific capacity, and low internal resistance. The specific capacity is up to 787.5 F g-1 at a discharge current of 2.5 mA and decreases slightly with 4.039% loss after 500 cycles, while the equivalent internal resistance is ˜3.067 Ω. Owing to its favorable electrochemical performance, this ordered hybrid array nanostructure is a promising electrode material in future commercial ES.

  13. Production of atmospheric pressure diffuse nanosecond pulsed dielectric barrier discharge using the array needles-plate electrode in air

    International Nuclear Information System (INIS)

    Yang Dezheng; Wang Wenchun; Jia Li; Nie Dongxia; Shi Hengchao

    2011-01-01

    In this paper, a bidirectional high pulse voltage with 20 ns rising time is employed to generate an atmospheric pressure diffuse dielectric barrier discharge using the array needles-plate electrode configuration. Both double needle and multiple needle electrode configurations nanosecond pulsed dielectric barrier discharges are investigated. It is found that a diffuse discharge plasma with low gas temperature can be obtained, and the plasma volume increases with the increase of the pulse peak voltage, but remains almost constant with the increase of the pulse repetition rate. In addition to showing the potential application on a topographically nonuniform surface treatment of the discharge, the multiple needle-plate electrode configuration with different needle-plate electrode gaps are also employed to generate diffuse discharge plasma.

  14. Biaxially stretchable supercapacitors based on the buckled hybrid fiber electrode array

    Science.gov (United States)

    Zhang, Nan; Zhou, Weiya; Zhang, Qiang; Luan, Pingshan; Cai, Le; Yang, Feng; Zhang, Xiao; Fan, Qingxia; Zhou, Wenbin; Xiao, Zhuojian; Gu, Xiaogang; Chen, Huiliang; Li, Kewei; Xiao, Shiqi; Wang, Yanchun; Liu, Huaping; Xie, Sishen

    2015-07-01

    In order to meet the growing need for smart bionic devices and epidermal electronic systems, biaxial stretchability is essential for energy storage units. Based on porous single-walled carbon nanotube/poly(3,4-ethylenedioxythiophene) (SWCNT/PEDOT) hybrid fiber, we designed and fabricated a biaxially stretchable supercapacitor, which possesses a unique configuration of the parallel buckled hybrid fiber array. Owing to the reticulate SWCNT film and the improved fabrication technique, the hybrid fiber retained its porous architecture both outwardly and inwardly, manifesting a superior capacity of 215 F g-1. H3PO4-polyvinyl alcohol gel with an optimized component ratio was introduced as both binder and stretchable electrolyte, which contributed to the regularity and stability of the buckled fiber array. The buckled structure and the quasi one-dimensional character of the fibers endow the supercapacitor with 100% stretchability along all directions. In addition, the supercapacitor exhibited good transparency, as well as excellent electrochemical properties and stability after being stretched 5000 times.In order to meet the growing need for smart bionic devices and epidermal electronic systems, biaxial stretchability is essential for energy storage units. Based on porous single-walled carbon nanotube/poly(3,4-ethylenedioxythiophene) (SWCNT/PEDOT) hybrid fiber, we designed and fabricated a biaxially stretchable supercapacitor, which possesses a unique configuration of the parallel buckled hybrid fiber array. Owing to the reticulate SWCNT film and the improved fabrication technique, the hybrid fiber retained its porous architecture both outwardly and inwardly, manifesting a superior capacity of 215 F g-1. H3PO4-polyvinyl alcohol gel with an optimized component ratio was introduced as both binder and stretchable electrolyte, which contributed to the regularity and stability of the buckled fiber array. The buckled structure and the quasi one-dimensional character of the

  15. Barbed channels enhance unidirectional connectivity between neuronal networks cultured on multi electrode arrays

    Science.gov (United States)

    le Feber, Joost; Postma, Wybren; de Weerd, Eddy; Weusthof, Marcel; Rutten, Wim L. C.

    2015-01-01

    Cultured neurons on multi electrode arrays (MEAs) have been widely used to study various aspects of neuronal (network) functioning. A possible drawback of this approach is the lack of structure in these networks. At the single cell level, several solutions have been proposed to enable directed connectivity, and promising results were obtained. At the level of connected sub-populations, a few attempts have been made with promising results. First assessment of the designs' functionality, however, suggested room for further improvement. We designed a two chamber MEA aiming to create a unidirectional connection between the networks in both chambers (“emitting” and “receiving”). To achieve this unidirectionality, all interconnecting channels contained barbs that hindered axon growth in the opposite direction (from receiving to emitting chamber). Visual inspection showed that axons predominantly grew through the channels in the promoted direction. This observation was confirmed by spontaneous activity recordings. Cross-correlation between the signals from two electrodes inside the channels suggested signal propagation at ≈2 m/s from emitting to receiving chamber. Cross-correlation between the firing patterns in both chambers indicated that most correlated activity was initiated in the emitting chamber, which was also reflected by a significantly lower fraction of partial bursts (i.e., a one-chamber-only burst) in the emitting chamber. Finally, electrical stimulation in the emitting chamber induced a fast response in that chamber, and a slower response in the receiving chamber. Stimulation in the receiving chamber evoked a fast response in that chamber, but no response in the emitting chamber. These results confirm the predominantly unidirectional nature of the connecting channels from emitting to receiving chamber. PMID:26578869

  16. Barbed channels enhance unidirectional connectivity between neuronal networks cultured on multi electrode arrays.

    Directory of Open Access Journals (Sweden)

    Joost eLe Feber

    2015-11-01

    Full Text Available Cultured neurons on multi electrode arrays (MEAs have been widely used to study various as-pects of neuronal (network functioning. A possible drawback of this approach is the lack of structure in these networks. At the single cell level, several solutions have been proposed to ena-ble directed connectivity, and promising results were obtained. At the level of connected sub-populations, a few attempts have been made with promising results. First assessment of the de-signs’ functionality, however, suggested room for further improvement.We designed a two chamber MEA aiming to create a unidirectional connection between the net-works in both chambers (‘emitting’ and ‘receiving’. To achieve this unidirectionality, all inter-connecting channels contained barbs that hindered axon growth in the opposite direction (from receiving to emitting chamber. Visual inspection showed that axons predominantly grew through the channels in the promoted direction . This observation was confirmed by spontaneous activity recordings. Cross-correlation between the signals from two electrodes inside the channels suggested signal propagation at ≈2 m/s from emitting to receiving chamber. Cross-correlation between the firing patterns in both chambers indicated that most correlated activity was initiated in the emitting chamber, which was also reflected by a significantly lower fraction of partial bursts (e. a one-chamber-only burst in the emitting chamber. Finally, electrical stimulation in the emitting chamber induced a fast response in that chamber, and a slower response in the receiving chamber. Stimulation in the receiving chamber evoked a fast response in that chamber, but no response in the emitting chamber. These results confirm the predominantly unidirectional nature of the connecting channels from emitting to receiving chamber.

  17. Construction of cobalt sulfide/nickel core-branch arrays and their application as advanced electrodes for electrochemical energy storage

    International Nuclear Information System (INIS)

    Chen, Minghua; Zhang, Jiawei; Xia, Xinhui; Qi, Meili; Yin, Jinghua; Chen, Qingguo

    2016-01-01

    Graphical abstract: Self-supported CoS/Ni core-branch arrays prepared by the combination of hydrothermal and electrodeposition methods demonstrate with high specific capacity and good cycling stability. - Highlights: • Construct porous CoS/Ni core-branch arrays. • Core-branch arrays show high Li storage properties. • Core-branch structure is favorable for fast ion and electron transfer. • Porous conductive metal branch can keep structure stable. - Abstract: Design/fabrication of advanced electrodes with tailored functionality is critical for the development of advanced electrochemical devices. Herein, we report a powerful strategy for construction of high-quality cobalt sulfide (CoS)/Ni core-branch arrays via combined methods of hydrothermal and electro-deposition. Electrodeposited thin porous Ni branch is successfully decorated on the CoS nanowires arrays with the help of hydrothermal ZnO nanorods template. Enhanced mechanical stability and improved ion/electron transfer characteristics are achieved in this composite system. As compared to the pure CoS nanowires arrays, the CoS/Ni core-branch arrays show enhanced electrochemical performance with lower polarization, better high-rate capability and superior cycling life. A high capacity of 605 mAh g −1 at 2C and 371 mAh g −1 at 6C is obtained in the composite core-branch system, respectively. Our developed electrode design protocol can be applicable for fabrication of other advanced metal sulfides electrodes for applications in solar cells, batteries and supercapacitors.

  18. Fabrication of nano-electrode arrays of free-standing carbon nanotubes on nano-patterned substrate by imprint method

    Energy Technology Data Exchange (ETDEWEB)

    Chang, W.S., E-mail: paul@kimm.re.kr [Department of Nano Mechanics, Korea Institute of Machinery and Materials, 104 Sinseongno, Yuseong-gu Daejeon 305-343 (Korea, Republic of); Kim, J.W. [Gyeongbuk Hybrid Technology Institute, 36 Goeyeon-dong, Yeongcheon, Gyeongbuk 770-170 (Korea, Republic of); Choi, D.G. [Department of Nano Mechanics, Korea Institute of Machinery and Materials, 104 Sinseongno, Yuseong-gu Daejeon 305-343 (Korea, Republic of); Han, C.S. [Gyeongbuk Hybrid Technology Institute, 36 Goeyeon-dong, Yeongcheon, Gyeongbuk 770-170 (Korea, Republic of)

    2011-01-15

    The synthesis of isolated carbon nanotubes with uniform outer diameters and ordered spacing over wafer-scale areas was investigated for fabrication of nano-electrode arrays on silicon wafers for field emission and sensor devices. Multi-walled carbon nanotubes (MWCNTs) were grown on TiN electrode layer with iron catalyst patterned by nano-imprint lithography (NIL), which allows the precise placement of individual CNTs on a substrate. The proposed techniques, including plasma-enhanced chemical vapor deposition (PECVD) and NIL, are simple, inexpensive, and reproducible methods for fabrication of nano-scale devices in large areas. The catalyst patterns were defined by an array of circles with 200 nm in diameter, and variable lengths of pitch. The nano-patterned master and Fe catalyst were observed with good pattern fidelity over a large area by atomic force microscope (AFM) and scanning electron microscopy (SEM). Nano-electrodes of MWCNTs had diameters ranging from 50 nm to 100 nm and lengths of about 300 nm. Field emission tests showed the reducing ignition voltage as the geometry of nanotube arrays was controlled by catalyst patterning. These results showed a wafer-scale approach to the control of the size, pitch, and position of nano-electrodes of nanotubes for various applications including electron field-emission sources, electrochemical probes, functionalized sensor elements, and so on.

  19. Wireless sEMG System with a Microneedle-Based High-Density Electrode Array on a Flexible Substrate.

    Science.gov (United States)

    Kim, Minjae; Gu, Gangyong; Cha, Kyoung Je; Kim, Dong Sung; Chung, Wan Kyun

    2017-12-30

    Surface electromyography (sEMG) signals reflect muscle contraction and hence, can provide information regarding a user's movement intention. High-density sEMG systems have been proposed to measure muscle activity in small areas and to estimate complex motion using spatial patterns. However, conventional systems based on wet electrodes have several limitations. For example, the electrolyte enclosed in wet electrodes restricts spatial resolution, and these conventional bulky systems limit natural movements. In this paper, a microneedle-based high-density electrode array on a circuit integrated flexible substrate for sEMG is proposed. Microneedles allow for high spatial resolution without requiring conductive substances, and flexible substrates guarantee stable skin-electrode contact. Moreover, a compact signal processing system is integrated with the electrode array. Therefore, sEMG measurements are comfortable to the user and do not interfere with the movement. The system performance was demonstrated by testing its operation and estimating motion using a Gaussian mixture model-based, simplified 2D spatial pattern.

  20. Liquid-crystal microlens array with swing and adjusting focus and constructed by dual patterned ITO-electrodes

    Science.gov (United States)

    Dai, Wanwan; Xie, Xingwang; Li, Dapeng; Han, Xinjie; Liu, Zhonglun; Wei, Dong; Xin, Zhaowei; Zhang, Xinyu; Wang, Haiwei; Xie, Changsheng

    2018-02-01

    Under the condition of existing intense turbulence, the object's wavefront may be severely distorted. So, the wavefront sensors based on the traditional microlens array (MLA) with a fixed focal length can not be used to measure the wavefront effectively. In order to obtain a larger measurement range and higher measurement accuracy, we propose a liquid-crystal microlens array (LCMLA) with needed ability of swing focus over the focal plane and further adjusting focal length, which is constructed by a dual patterned ITO electrodes. The main structure of the LCMLA is divided into two layers, which are made of glass substrate with ITO transparent electrodes. The top layer of each liquid-crystal microlens consists of four rectangular electrodes, and the bottom layer is a circular electrode. In common optical measurements performed, the operations are carried out such as adding the same signal voltage over four electrodes of each microlens to adjust the focal length of the lens cell and adding a signal voltage with different RMS amplitude to adjust the focus position on the focal plane. Experiments show that the LCMLA developed by us demonstrate a desired focal length adjustable function and dynamic swing ability, so as to indicate that the method can be used not only to measure wavefront but also correct the wavefront with strong distortion.

  1. Factors Affecting Outcomes in Cochlear Implant Recipients Implanted With a Perimodiolar Electrode Array Located in Scala Tympani.

    Science.gov (United States)

    Holden, Laura K; Firszt, Jill B; Reeder, Ruth M; Uchanski, Rosalie M; Dwyer, Noël Y; Holden, Timothy A

    2016-12-01

    To identify primary biographic and audiologic factors contributing to cochlear implant (CI) performance variability in quiet and noise by controlling electrode array type and electrode position within the cochlea. Although CI outcomes have improved over time, considerable outcome variability still exists. Biographic, audiologic, and device-related factors have been shown to influence performance. Examining CI recipients with consistent array type and electrode position may allow focused investigation into outcome variability resulting from biographic and audiologic factors. Thirty-nine adults (40 ears) implanted for at least 6 months with a perimodiolar electrode array known (via computed tomography [CT] imaging) to be in scala tympani participated. Test materials, administered CI only, included monosyllabic words, sentences in quiet and noise, and spectral ripple discrimination. In quiet, scores were high with mean word and sentence scores of 76 and 87%, respectively; however, sentence scores decreased by an average of 35 percentage points when noise was added. A principal components (PC) analysis of biographic and audiologic factors found three distinct factors, PC1 Age, PC2 Duration, and PC3 Pre-op Hearing. PC1 Age was the only factor that correlated, albeit modestly, with speech recognition in quiet and noise. Spectral ripple discrimination strongly correlated with speech measures. For these recipients with consistent electrode position, PC1 Age was related to speech recognition performance. Consistent electrode position may have contributed to high speech understanding in quiet. Inter-subject variability in noise may have been influenced by auditory/cognitive processing, known to decline with age, and mechanisms that underlie spectral resolution ability.

  2. Mu rhythm desynchronization by tongue thrust observation

    Directory of Open Access Journals (Sweden)

    Kotoe eSakihara

    2015-09-01

    Full Text Available We aimed to investigate the mu rhythm in the sensorimotor area during tongue thrust observation and to obtain an answer to the question as to how subtle non-verbal orofacial movement observation activates the sensorimotor area. Ten healthy volunteers performed finger tap execution, tongue thrust execution, and tongue thrust observation. The electroencephalogram was recorded from 128 electrodes placed on the scalp, and regions of interest were set at sensorimotor areas. The event-related desynchronization (ERD and event-related synchronization (ERS for the mu rhythm (8–13 Hz and beta (13−25 Hz bands were measured. Tongue thrust observation induced mu rhythm ERD, and the ERD was detected at the left hemisphere regardless whether the observed tongue thrust was toward the left or right. Mu rhythm ERD was also recorded during tongue thrust execution. However, temporal analysis revealed that the ERD associated with tongue thrust observation preceded that associated with execution by approximately 2 s. Tongue thrust observation induces mu rhythm ERD in sensorimotor cortex with left hemispheric dominance.

  3. Microstructure and pseudocapacitive properties of electrodes constructed of oriented NiO-TiO2 nanotube arrays.

    Science.gov (United States)

    Kim, Jae-Hun; Zhu, Kai; Yan, Yanfa; Perkins, Craig L; Frank, Arthur J

    2010-10-13

    We report on the synthesis and electrochemical properties of oriented NiO-TiO(2) nanotube (NT) arrays as electrodes for supercapacitors. The morphology of the films prepared by electrochemically anodizing Ni-Ti alloy foils was characterized by scanning and transmission electron microscopies, X-ray diffraction, and photoelectron spectroscopies. The morphology, crystal structure, and composition of the NT films were found to depend on the preparation conditions (anodization voltage and postgrowth annealing temperature). Annealing the as-grown NT arrays to a temperature of 600 °C transformed them from an amorphous phase to a mixture of crystalline rock salt NiO and rutile TiO(2). Changes in the morphology and crystal structure strongly influenced the electrochemical properties of the NT electrodes. Electrodes composed of NT films annealed at 600 °C displayed pseudocapacitor (redox-capacitor) behavior, including rapid charge/discharge kinetics and stable long-term cycling performance. At similar film thicknesses and surface areas, the NT-based electrodes showed a higher rate capability than the randomly packed nanoparticle-based electrodes. Even at the highest scan rate (500 mV/s), the capacitance of the NT electrodes was not much smaller (within 12%) than the capacitance measured at the slowest scan rate (5 mV/s). The faster charge/discharge kinetics of NT electrodes at high scan rates is attributed to the more ordered NT film architecture, which is expected to facilitate electron and ion transport during the charge-discharge reactions.

  4. Study of the Carrier-Aided Thin Film Electrode Array Design for Cochlear Insertion

    Directory of Open Access Journals (Sweden)

    Yuchen Xu

    2018-04-01

    Full Text Available The micro-fabricated thin film electrode array (TFEA has been a promising design for cochlear implants (CIs because of its cost-effectiveness and fabrication precision. The latest polymer-based cochlear TFEAs have faced difficulties for cochlear insertion due to the lack of structural stiffness. To stiffen the TFEA, dissolvable stiffening materials, TFEAs with different structures, and TFEAs with commercial CIs as carriers have been invested. In this work, the concept of enhancing a Parylene TFEA with Kapton tape as a simpler carrier for cochlear insertion has been proved to be feasible. The bending stiffness of the Kapton-aided TFEA was characterized with an analytical model, a finite element model, and a cantilever bending experiment, respectively. While the Kapton tape increased the bending stiffness of the Parylene TFEA by 103 times, the 6-μm-thick TFEA with a similar Young’s modulus, as a polyimide, in turn significantly increased the bending stiffness of the 170-μm-thick Kapton carrier by 60%. This result indicated that even the TFEA is ultra-flexible and that its bending stiffness should not be neglected in the design or selection of its carrier.

  5. All-carbon multi-electrode array for real-time in vitro measurements of oxidizable neurotransmitters

    Science.gov (United States)

    Picollo, Federico; Battiato, Alfio; Bernardi, Ettore; Plaitano, Marilena; Franchino, Claudio; Gosso, Sara; Pasquarelli, Alberto; Carbone, Emilio; Olivero, Paolo; Carabelli, Valentina

    2016-02-01

    We report on the ion beam fabrication of all-carbon multi electrode arrays (MEAs) based on 16 graphitic micro-channels embedded in single-crystal diamond (SCD) substrates. The fabricated SCD-MEAs are systematically employed for the in vitro simultaneous amperometric detection of the secretory activity from populations of chromaffin cells, demonstrating a new sensing approach with respect to standard techniques. The biochemical stability and biocompatibility of the SCD-based device combined with the parallel recording of multi-electrodes array allow: i) a significant time saving in data collection during drug screening and/or pharmacological tests over a large number of cells, ii) the possibility of comparing altered cell functionality among cell populations, and iii) the repeatition of acquisition runs over many cycles with a fully non-toxic and chemically robust bio-sensitive substrate.

  6. Cone-beam computed tomography in children with cochlear implants: The effect of electrode array position on ECAP.

    Science.gov (United States)

    Lathuillière, Marine; Merklen, Fanny; Piron, Jean-Pierre; Sicard, Marielle; Villemus, Françoise; Menjot de Champfleur, Nicolas; Venail, Frédéric; Uziel, Alain; Mondain, Michel

    2017-01-01

    To assess the feasibility of using cone-beam computed tomography (CBCT) in young children with cochlear implants (CIs) and study the effect of intracochlear position on electrophysiological and behavioral measurements. A total of 40 children with either unilateral or bilateral cochlear implants were prospectively included in the study. Electrode placement and insertion angles were studied in 55 Cochlear ® implants (16 straight arrays and 39 perimodiolar arrays), using either CBCT or X-ray imaging. CBCT or X-ray imaging were scheduled when the children were leaving the recovery room. We recorded intraoperative and postoperative neural response telemetry threshold (T-NRT) values, intraoperative and postoperative electrode impedance values, as well as behavioral T (threshold) and C (comfort) levels on electrodes 1, 5, 10, 15 and 20. CBCT imaging was feasible without any sedation in 24 children (60%). Accidental scala vestibuli insertion was observed in 3 out of 24 implants as assessed by CBCT. The mean insertion angle was 339.7°±35.8°. The use of a perimodiolar array led to higher angles of insertion, lower postoperative T-NRT, as well as decreased behavioral T and C levels. We found no significant effect of either electrode array position or angle of insertion on electrophysiological data. CBCT appears to be a reliable tool for anatomical assessment of young children with CIs. Intracochlear position had no significant effect on the electrically evoked compound action potential (ECAP) threshold. Our CBCT protocol must be improved to increase the rate of successful investigations. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Vertically Aligned Co9 S8 Nanotube Arrays onto Graphene Papers as High-Performance Flexible Electrodes for Supercapacitors.

    Science.gov (United States)

    Xiong, Dongbin; Li, Xifei; Bai, Zhimin; Li, Jianwei; Han, Yan; Li, Dejun

    2018-02-16

    Paper-like electrodes are emerging as a new category of advanced electrodes for flexible supercapacitors (SCs). Graphene, a promising two-dimensional material with high conductivity, can be easily processed into papers. Here, we report a rational design of flexible architecture with Co 9 S 8 nanotube arrays (NAs) grown onto graphene paper (GP) via a facile two-step hydrothermal method. When employed as flexible free-standing electrode for SCs, the proposed architectured Co 9 S 8 /GPs exhibits superior electrochemical performance with ultrahigh capacitance and outstanding rate capability (469 F g -1 at 10 A g -1 ). These results demonstrate that the new nanostructured Co 9 S 8 /GPs can be potentially applied in high performance flexible supercapacitors. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Stretchable, Transparent, and Stretch-Unresponsive Capacitive Touch Sensor Array with Selectively Patterned Silver Nanowires/Reduced Graphene Oxide Electrodes.

    Science.gov (United States)

    Choi, Tae Young; Hwang, Byeong-Ung; Kim, Bo-Yeong; Trung, Tran Quang; Nam, Yun Hyoung; Kim, Do-Nyun; Eom, Kilho; Lee, Nae-Eung

    2017-05-31

    Stretchable and transparent touch sensors are essential input devices for future stretchable transparent electronics. Capacitive touch sensors with a simple structure of only two electrodes and one dielectric are an established technology in current rigid electronics. However, the development of stretchable and transparent capacitive touch sensors has been limited due to changes in capacitance resulting from dimensional changes in elastomeric dielectrics and difficulty in obtaining stretchable transparent electrodes that are stable under large strains. Herein, a stretch-unresponsive stretchable and transparent capacitive touch sensor array was demonstrated by employing stretchable and transparent electrodes with a simple selective-patterning process and by carefully selecting dielectric and substrate materials with low strain responsivity. A selective-patterning process was used to embed a stretchable and transparent silver nanowires/reduced graphene oxide (AgNWs/rGO) electrode line into a polyurethane (PU) dielectric layer on a polydimethylsiloxane (PDMS) substrate using oxygen plasma treatment. This method provides the ability to directly fabricate thin film electrode lines on elastomeric substrates and can be used in conventional processes employed in stretchable electronics. We used a dielectric (PU) with a Poisson's ratio smaller than that of the substrate (PDMS), which prevented changes in the capacitance resulting from stretching of the sensor. The stretch-unresponsive touch sensing capability of our transparent and stretchable capacitive touch sensor has great potential in wearable electronics and human-machine interfaces.

  9. Supported noble metals on hydrogen-treated TiO2 nanotube arrays as highly ordered electrodes for fuel cells.

    Science.gov (United States)

    Zhang, Changkun; Yu, Hongmei; Li, Yongkun; Gao, Yuan; Zhao, Yun; Song, Wei; Shao, Zhigang; Yi, Baolian

    2013-04-01

    Hydrogen-treated TiO2 nanotube (H-TNT) arrays serve as highly ordered nanostructured electrode supports, which are able to significantly improve the electrochemical performance and durability of fuel cells. The electrical conductivity of H-TNTs increases by approximately one order of magnitude in comparison to air-treated TNTs. The increase in the number of oxygen vacancies and hydroxyl groups on the H-TNTs help to anchor a greater number of Pt atoms during Pt electrodeposition. The H-TNTs are pretreated by using a successive ion adsorption and reaction (SIAR) method that enhances the loading and dispersion of Pt catalysts when electrodeposited. In the SIAR method a Pd activator can be used to provide uniform nucleation sites for Pt and leads to increased Pt loading on the H-TNTs. Furthermore, fabricated Pt nanoparticles with a diameter of 3.4 nm are located uniformly around the pretreated H-TNT support. The as-prepared and highly ordered electrodes exhibit excellent stability during accelerated durability tests, particularly for the H-TNT-loaded Pt catalysts that have been annealed in ultrahigh purity H2 for a second time. There is minimal decrease in the electrochemical surface area of the as-prepared electrode after 1000 cycles compared to a 68 % decrease for the commercial JM 20 % Pt/C electrode after 800 cycles. X-ray photoelectron spectroscopy shows that after the H-TNT-loaded Pt catalysts are annealed in H2 for the second time, the strong metal-support interaction between the H-TNTs and the Pt catalysts enhances the electrochemical stability of the electrodes. Fuel-cell testing shows that the power density reaches a maximum of 500 mWcm(-2) when this highly ordered electrode is used as the anode. When used as the cathode in a fuel cell with extra-low Pt loading, the new electrode generates a specific power density of 2.68 kWg(Pt) (-1) . It is indicated that H-TNT arrays, which have highly ordered nanostructures, could be used as ordered electrode supports

  10. Enhanced supercapacitor performance using hierarchical TiO2 nanorod/Co(OH)2 nanowall array electrodes

    International Nuclear Information System (INIS)

    Ramadoss, Ananthakumar; Kim, Sang Jae

    2014-01-01

    Graphical abstract: - Highlights: • TiO 2 /Co(OH) 2 hierarchical nanostructure was prepared by a combination of hydrothermal and cathodic electrodeposition method. • Hierarchical nanostructure electrode exhibited a maximum capacitance of 274.3 mF cm −2 at a scan rate of 5 mV s −1 . • Combination of Co(OH) 2 nanowall with TiO 2 NR into a single system enhanced the electrochemical behavior of supercapacitor electrode. - Abstract: We report novel hierarchical TiO 2 nanorod (NR)/porous Co(OH) 2 nanowall array electrodes for high-performance supercapacitors fabricated using a two-step process that involves hydrothermal and electrodeposition techniques. Field-emission scanning electron microscope images reveal a bilayer structure consisting of TiO 2 NR arrays with porous Co(OH) 2 nanowalls. Compared with the bare TiO 2 NRs, the hierarchical TiO 2 NRs/Co(OH) 2 electrodes showed improved pseudocapacitive performance in a 2-M KOH electrolyte solution, exhibiting an areal specific capacitance of 274.3 mF cm −2 at a scan rate of 5 mV s −1 . The electrodes exhibited good stability, retaining 82.5% of the initial capacitance after 4000 cycles. The good pseudocapacitive performance of the hierarchical nanostructures is mainly due to the porous structure, which provides fast ion and electron transfer, a large surface area, short ion diffusion paths, and a favourable volume change during the cycling process

  11. Ni nanotube array-based electrodes by electrochemical alloying and de-alloying for efficient water splitting.

    Science.gov (United States)

    Teng, Xue; Wang, Jianying; Ji, Lvlv; Lv, Yaokang; Chen, Zuofeng

    2018-05-17

    The design of cost-efficient earth-abundant catalysts with superior performance for the hydrogen evolution reaction (HER) and oxygen evolution reaction (OER) is extremely important for future renewable energy production. Herein, we report a facile strategy for constructing Ni nanotube arrays (NTAs) on a Ni foam (NF) substrate through cathodic deposition of NiCu alloy followed by anodic stripping of metallic Cu. Based on Ni NTAs, the as-prepared NiSe2 NTA electrode by NiSe2 electrodeposition and the NiFeOx NTA electrode by dipping in Fe3+ solution exhibit excellent HER and OER performance in alkaline conditions. In these systems, Ni NTAs act as a binder-free multifunctional inner layer to support the electrocatalysts, offer a large specific surface area and serve as a fast electron transport pathway. Moreover, an alkaline electrolyzer has been constructed using NiFeOx NTAs as the anode and NiSe2 NTAs as the cathode, which only demands a cell voltage of 1.78 V to deliver a water-splitting current density of 500 mA cm-2, and demonstrates remarkable stability during long-term electrolysis. This work provides an attractive method for the design and fabrication of nanotube array-based catalyst electrodes for highly efficient water-splitting.

  12. Redox cycling with facing interdigitated array electrodes as a method for selective detection of redox species

    NARCIS (Netherlands)

    Dam, T.V.A.; Olthuis, Wouter; van den Berg, Albert

    2007-01-01

    A pair of interdigitated ultramicroelectrodes (UMEs) is used to electrochemically detect a weak reductor ( dopamine) in the presence of a stronger one (K-4[ Fe(CN)(6)]). In the mixture of both reductors, one of the two interdigitated electrodes ( the generator electrode) is used to oxidize both

  13. Redox cycling with facing interdigitated array electrodes as a method for selective detection of redox species

    NARCIS (Netherlands)

    Dam, V.A.T.; Olthuis, W.; Berg, van den A.

    2007-01-01

    A pair of interdigitated ultramicroelectrodes (UMEs) is used to electrochemically detect a weak reductor (dopamine) in the presence of a stronger one (K4[Fe(CN)6]). In the mixture of both reductors, one of the two interdigitated electrodes (the generator electrode) is used to oxidize both species at

  14. Ternary nanocomposite of polyaniline/manganese dioxide/titanium nitride nanowire array for supercapacitor electrode

    International Nuclear Information System (INIS)

    Xia, Chi; Xie, Yibing; Du, Hongxiu; Wang, Wei

    2015-01-01

    The electroactive polyaniline (PANI) and manganese oxide (MnO 2 ) were integrated with titanium nitride (TiN) nanowire array (NWA) to form PANI/MnO 2 /TiN ternary nanocomposite for supercapacitor application. TiN NWA was prepared via a seed-assisted hydrothermal synthesis and ammonia nitridization process. The electroactive MnO 2 and PANI was layer-by-layer coated on TiN NWA to form heterogeneous coaxial structure through a stepwise electrodeposition process. Scanning electron micrographs revealed that the well-separated TiN NWA was composed of well-distributed nanowires with diameters in the range of 10–30 nm and a total length of 1.5 μm. A villiform MnO 2 layer with a thickness of 10–20 nm covered on TiN NWA to form MnO 2 /TiN NWA composite. The coral-like PANI layer with thicknesses in the range of 20–50 nm covered on the above MnO 2 /TiN NWA to form PANI/MnO 2 /TiN NWA. Electrochemical measurements showed that a high specific capacitance of 674 F g −1 at a current density of 1 A g −1 (based on total mass of PANI/MnO 2 ) was obtained for PANI/MnO 2 /TiN NWA ternary nanocomposite, which was much higher than that of PANI/MnO 2 /carbon-cloth composites reported previously. This ternary nanocomposite also showed a good rate and cycling stability. Moreover, in comparison with PANI/TiN NWA or MnO 2 /TiN NWA, the specific capacitance of PANI/MnO 2 /TiN NWA was obviously enhanced due to the extra pseudocapacitance contribution and the effective surface area of coral-like PANI layer, showing the advantage of manipulating the heterogeneous coaxial configuration between PANI and MnO 2 for fundamentally improved capacitive performance. These results demonstrated that PANI/MnO 2 /TiN NWA ternary nanocomposite was a promising candidate electrode material for supercapacitor application

  15. Ternary nanocomposite of polyaniline/manganese dioxide/titanium nitride nanowire array for supercapacitor electrode

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Chi; Xie, Yibing, E-mail: ybxie@seu.edu.cn; Du, Hongxiu; Wang, Wei [Southeast University, School of Chemistry and Chemical Engineering (China)

    2015-01-15

    The electroactive polyaniline (PANI) and manganese oxide (MnO{sub 2}) were integrated with titanium nitride (TiN) nanowire array (NWA) to form PANI/MnO{sub 2}/TiN ternary nanocomposite for supercapacitor application. TiN NWA was prepared via a seed-assisted hydrothermal synthesis and ammonia nitridization process. The electroactive MnO{sub 2} and PANI was layer-by-layer coated on TiN NWA to form heterogeneous coaxial structure through a stepwise electrodeposition process. Scanning electron micrographs revealed that the well-separated TiN NWA was composed of well-distributed nanowires with diameters in the range of 10–30 nm and a total length of 1.5 μm. A villiform MnO{sub 2} layer with a thickness of 10–20 nm covered on TiN NWA to form MnO{sub 2}/TiN NWA composite. The coral-like PANI layer with thicknesses in the range of 20–50 nm covered on the above MnO{sub 2}/TiN NWA to form PANI/MnO{sub 2}/TiN NWA. Electrochemical measurements showed that a high specific capacitance of 674 F g{sup −1} at a current density of 1 A g{sup −1} (based on total mass of PANI/MnO{sub 2}) was obtained for PANI/MnO{sub 2}/TiN NWA ternary nanocomposite, which was much higher than that of PANI/MnO{sub 2}/carbon-cloth composites reported previously. This ternary nanocomposite also showed a good rate and cycling stability. Moreover, in comparison with PANI/TiN NWA or MnO{sub 2}/TiN NWA, the specific capacitance of PANI/MnO{sub 2}/TiN NWA was obviously enhanced due to the extra pseudocapacitance contribution and the effective surface area of coral-like PANI layer, showing the advantage of manipulating the heterogeneous coaxial configuration between PANI and MnO{sub 2} for fundamentally improved capacitive performance. These results demonstrated that PANI/MnO{sub 2}/TiN NWA ternary nanocomposite was a promising candidate electrode material for supercapacitor application.

  16. Impedance biosensor based on interdigitated electrode array for detection of E.coli O157:H7 in food products

    Science.gov (United States)

    Ghosh Dastider, Shibajyoti; Barizuddin, Syed; Dweik, Majed; Almasri, Mahmoud F.

    2012-05-01

    An impedance biosensor was designed, fabricated and tested for detection of viable Escherichia coli O157:H7 in food samples. This device consists of interdigitated microelectrode array (IDEA) fabricated using thin layer of sputtered gold, embedded under a polydimethylsiloxane (PDMS) microchannel. The array of electrodes is designed to detect viable EColi in different food products. The active surface area of the detection array was modified using goat anti-E.coli polyclonal IgG antibody. Contaminated food samples were tested by infusing the supernatant containing bacteria over the IDEA's, through the microchannel. Antibody-antigen binding on the electrodes results in impedance change. Four serial concentrations of E.coli contaminated food samples (3x102 CFUmL-1 to 3x105 CFUmL-1) were tested. The biosensor successfully detected the E.coli samples, with the lower detection limit being 3x103 CFUmL-1 (up to 3cells/μl). Comparing the test results with an IDEA impedance biosensor without microchannel (published elsewhere) indicates that this biosensor have two order of magnitude times higher sensitivity. The proposed biosensor provides qualitative and quantitative detection, and potentially could be used for detection of other type of bacteria by immobilizing the specific type of antibody.

  17. A stretchable electrode array for non-invasive, skin-mounted measurement of electrocardiography (ECG), electromyography (EMG) and electroencephalography (EEG).

    Science.gov (United States)

    Ma, Rui; Kim, Dae-Hyeong; McCormick, Martin; Coleman, Todd; Rogers, John

    2010-01-01

    This paper reports a class of stretchable electrode array capable of intimate, conformal integration onto the curvilinear surfaces of skin on the human body. The designs employ conventional metallic conductors but in optimized mechanical layouts, on soft, thin elastomeric substrates. These devices exhibit an ability to record spontaneous EEG activity even without conductive electrolyte gels, with recorded alpha rhythm responses that are 40% stronger than those collected using conventional tin electrodes and gels under otherwise similar conditions. The same type of device can also measure high quality ECG and EMG signals. The results suggest broad utility for skin-mounted measurements of electrical activity in the body, with advantages in signal levels, wearability and modes of integration compared to alternatives.

  18. Nickel Nanowire@Porous NiCo2O4 Nanorods Arrays Grown on Nickel Foam as Efficient Pseudocapacitor Electrode

    Directory of Open Access Journals (Sweden)

    Houzhao Wan

    2017-12-01

    Full Text Available A three dimensional hierarchical nanostructure composed of nickel nanowires and porous NiCo2O4 nanorods arrays on the surface of nickel foam is successfully fabricated by a facile route. In this structure, the nickel nanowires are used as core materials to support high-pseudocapacitance NiCo2O4 nanorods and construct the well-defined NiCo2O4 nanorods shell/nickel nanowires core hierarchical structure on nickel foam. Benefiting from the participation of nickel nanowires, the nickel nanowire@NiCo2O4/Ni foam electrode shows a high areal specific capacitance (7.4 F cm−2 at 5 mA cm−2, excellent rate capability (88.04% retained at 100 mA cm−2, and good cycling stability (74.08% retained after 1,500 cycles. The superior electrochemical properties made it promising as electrode for supercapacitors.

  19. Insertion characteristics and placement of the Mid-Scala electrode array in human temporal bones using detailed cone beam computed tomography.

    Science.gov (United States)

    Dietz, Aarno; Gazibegovic, Dzemal; Tervaniemi, Jyrki; Vartiainen, Veli-Matti; Löppönen, Heikki

    2016-12-01

    The aim of this study was to evaluate the insertion results and placement of the new Advanced Bionics HiFocus Mid-Scala (HFms) electrode array, inserted through the round window membrane, in eight fresh human temporal bones using cone beam computed tomography (CBCT). Pre- and post-insertion CBCT scans were registered to create a 3D reconstruction of the cochlea with the array inserted. With an image fusion technique both the bony edges of the cochlea and the electrode array in situ could accurately be determined, thus enabling to identify the exact position of the electrode array within the scala tympani. Vertical and horizontal scalar location was measured at four points along the cochlea base at an angular insertion depth of 90°, 180° and 270° and at electrode 16, the most basal electrode. Smooth insertion through the round window membrane was possible in all temporal bones. The imaging results showed that there were no dislocations from the scala tympani into the scala vestibule. The HFms electrode was positioned in the middle of the scala along the whole electrode array in three out of the eight bones and in 62 % of the individual locations measured along the base of the cochlea. In only one cochlea a close proximity of the electrode with the basilar membrane was observed, indicating possible contact with the basilar membrane. The results and assessments presented in this study appear to be highly accurate. Although a further validation including histopathology is needed, the image fusion technique described in this study represents currently the most accurate method for intracochlear electrode assessment obtainable with CBCT.

  20. Binary cobalt ferrite nanomesh arrays as the advanced binder-free electrode for applications in oxygen evolution reaction and supercapacitors

    Science.gov (United States)

    Liu, Li; Zhang, Huijuan; Mu, Yanping; Bai, Yuanjuan; Wang, Yu

    2016-09-01

    The porous CoFe2O4nanomesh arrays are successfully synthesized on nickel foam substrate through a high temperature and pressure hydrothermal method, following by the thermal post-treatment in air. The CoFe2O4 nanomesh arrays own numerous pores and large specific surface area, which is in favor of exposing more active sites. In consideration of the structural preponderances and versatility of the materials, the CoFe2O4 nanomesh arrays have been researched as the binder-free electrode materials for electrocatalysis and supercapacitors. When the CoFe2O4nanomesh arrays on nickel foam (CoFe2O4 NM-As/Ni) directly act as the free-binder catalyst toward catalyzing the oxygen evolution reaction (OER) of electrochemical water splitting, CoFe2O4 NM-As/Ni exhibits an admirable OER property with a low onset potential of 1.47 V(corresponding to the onset overpotential of 240 mV), a minimal overpotential (η10 = 253 mV), a small Tafel slope (44 mV dec-1), large anodic currents and long-term durability for 35 h in alkaline media. In addition, as an electrode of supercapacitors, CoFe2O4 NM-As/Ni obtains a desired specific capacitance (1426 F/g at the current density of 1 A/g), remarkable rate capability (1024 F/g at the current density of 20 A/g) and eminent capacitance retention (92.6% after 3000 cycles). The above results demonstrate the CoFe2O4 NM-As/Ni possesses great potential application in electrocatalysis and supercapacitors.

  1. Insertion forces and intracochlear trauma in temporal bone specimens implanted with a straight atraumatic electrode array.

    Science.gov (United States)

    Mirsalehi, Marjan; Rau, Thomas S; Harbach, Lenka; Hügl, Silke; Mohebbi, Saleh; Lenarz, Thomas; Majdani, Omid

    2017-05-01

    The aim of the study was to evaluate insertion forces during manual insertion of a straight atraumatic electrode in human temporal bones, and post-implantation histologic evaluation of the samples to determine whether violation of intracochlear structures is related to insertion forces. In order to minimize intracochlear trauma and preserve residual hearing during cochlear implantation, knowledge of the insertion forces is necessary. Ten fresh frozen human temporal bones were prepared with canal wall down mastoidectomy. All samples were mounted on a one-axis force sensor. Insertion of a 16-mm straight atraumatic electrode was performed from different angles to induce "traumatic" insertion. Histologic evaluation was performed in order to evaluate intracochlear trauma. In 4 of 10 samples, dislocation of the electrode into scala vestibuli was observed. The mean insertion force for all 10 procedures was 0.003 ± 0.005 N. Insertion forces measured around the site of dislocation to scala vestibuli in 3 of 4 samples were significantly higher than insertion forces at the same location of the cochleae measured in samples without trauma (p straight atraumatic electrode is lower than reported by other studies using longer electrodes. Based on our study, insertion forces leading to basilar membrane trauma may be lower than the previously reported direct rupture forces.

  2. A disposable electrochemical immunosensor arrays using 4-channel screen-printed carbon electrode for simultaneous detection of Escherichia coli O157:H7 and Enterobacter sakazakii

    International Nuclear Information System (INIS)

    Dou, Wenchao; Tang, Weilu; Zhao, Guangying

    2013-01-01

    An electrochemical immunosensor for Escherichia coli O157:H7 (E. coli O157:H7) and Enterobacter sakazakii (E. sakazakii) detection using carbon screen-printed low-density arrays is reported. The sensors were fabricated based on screen-printed carbon arrays containing four carbon working electrode, an integrated carbon counter electrodes and an integrated Ag/AgCl reference electrode. Multi-walled carbon nanotubes (MWCNTs)/sodium alginate (SA)/carboxymethyl chitosan (CMC) composite films were coated on all the working electrodes to enhance the sensitization of the electrode. Horseradish peroxidases (HRP) labeled antibodies of two bacteria were immobilize on different working electrode of the same screen-printed electrode respectively. The immobilization of MWCNTs, HRP labeled antibodies onto the screen-printed carbon electrodes was examined using atom force microscopy (AFM) and cyclic voltammetry (CV). The analytical performance of proposed immunosensor arrays toward E. sakazakii and E. coli O157:H7 was investigated by AFM and CV. Under optimal conditions, the linear range of E. sakazakii and E. coli O157:H7 were from 10 4 to 10 10 cfu/ml, with a detection limit of 4.57 × 10 3 cfu/ml (S/N = 3) and 3.27 × 10 3 cfu/ml (S/N = 3), respectively. The specificity, reproducibility, stability and accuracy of the proposed immunosensor arrays were also evaluated. Two antibodies modified work electrodes were tested and compared in terms of sensitivity and ability to recognize different pathogenic biological species

  3. Improving electrochemical performance of flexible thin film electrodes with micropillar array structures

    International Nuclear Information System (INIS)

    Myllymaa, Sami; Myllymaa, Katja; Lappalainen, Reijo; Pirinen, Sami; Pakkanen, Tapani A; Pakkanen, Tuula T; Suvanto, Mika

    2012-01-01

    For reliable function, bioelectrodes require a stable, low-impedance contact with the target tissue. In biosignal monitoring applications, in which low ion current densities are recorded, it is important to minimize electrode contact impedances. Recently, several flexible electrode concepts have been introduced for single-patient use. These electrodes conform well on the patient skin enabling an artifact-free, low-noise recording. In this study, polydimethylsiloxane (PDMS) elastomer was used as an electrode substrate material. One half of the substrates were surface-patterned with micropillars produced by using micro-working robot-made mold inserts and a replica molding technique. The substrates were subsequently coated with thin films of titanium (Ti), copper (Cu), silver (Ag) or silver–silver chloride (Ag/AgCl). Electrical impedance spectroscopy studies revealed that the micropillar structure caused statistically significant reductions in impedance modulus and phase for each coating candidate. The relative effect was strongest for pure Ag, for which the values of the real part (Z′) and the imaginary part (Z″) decreased to less than one tenth of the original (smooth) values. However, Ag/AgCl, as expected, proved to be a superior electrode material. Coating with chloride drastically reduced the interfacial impedance compared to pure Ag. Further significant reduction was achieved by the micropillars, since the phase angle declined from 10–13° (for smooth samples, f < 50 Hz) to a value as low as 5°. Equivalent circuit modeling was used to obtain a better understanding of phenomena occurring at various electrode–electrolyte interfaces. The knowledge obtained in this study will be exploited in the further development of flexible electrodes and miniaturized biointerfaces with improved electrochemical characteristics. (paper)

  4. Highly catalytic and stabilized titanium nitride nanowire array-decorated graphite felt electrodes for all vanadium redox flow batteries

    Science.gov (United States)

    Wei, L.; Zhao, T. S.; Zeng, L.; Zeng, Y. K.; Jiang, H. R.

    2017-02-01

    In this work, we prepare a highly catalytic and stabilized titanium nitride (TiN) nanowire array-decorated graphite felt electrode for all vanadium redox flow batteries (VRFBs). Free-standing TiN nanowires are synthesized by a two-step process, in which TiO2 nanowires are first grown onto the surface of graphite felt via a seed-assisted hydrothermal method and then converted to TiN through nitridation reaction. When applied to VRFBs, the prepared electrode enables the electrolyte utilization and energy efficiency to be 73.9% and 77.4% at a high current density of 300 mA cm-2, which are correspondingly 43.3% and 15.4% higher than that of battery assembled with a pristine electrode. More impressively, the present battery exhibits good stability and high capacity retention during the cycle test. The superior performance is ascribed to the significant improvement in the electrochemical kinetics and enlarged active sites toward V3+/V2+ redox reaction.

  5. Toward selective electrochemical 'E-tongue': Potentiometric DO sensor based on sub-micron ZnO-RuO{sub 2} sensing electrode

    Energy Technology Data Exchange (ETDEWEB)

    Zhuiykov, Serge, E-mail: serge.zhuiykov@csiro.au [CSIRO, Materials Science and Engineering Division, 37 Graham Road, Highett, VIC 3190 (Australia); Kats, Eugene [CSIRO, Materials Science and Engineering Division, 37 Graham Road, Highett, VIC 3190 (Australia); Plashnitsa, Vladimir [Research and Education Centre of Carbon Resources, Kyushu University, Kasuga-shi, Fukuoka 816-8580 (Japan); Miura, Norio [KASTEC, Kyushu University, Kasuga-shi, Fukuoka 816-8580 (Japan)

    2011-06-01

    Highlights: > We examine ZnO-doped RuO{sub 2} sensing electrode of DO sensor. > Study of ZnO-RuO{sub 2} confirmed the development of high surface-to-volume ratio. > Developed sensing electrode is insensitive to the presence of various dissolved salts. > 20 mol% ZnO-doped RuO{sub 2} sensing electrode enables maximum DO sensitivity. > We conclude that DO sensor based on ZnO-RuO{sub 2} electrode can work at 11-30 deg. C. - Abstract: Planar dissolved oxygen (DO) sensors based on thick-film ZnO-RuO{sub 2} sensing electrodes (SEs) with different mol% of ZnO were prepared on the alumina substrates using a screen-printing method and their structural and electrochemical properties were closely studied by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), energy-dispersive X-ray analysis (EDX), electrochemical impedance spectroscopy (EIS) and energy-dispersive spectroscopy (EDS) techniques. Structural and electrochemical properties of ZnO-RuO{sub 2}-SEs have been investigated. Interference testing ascertained that the DO sensor based on sub-micron ZnO-RuO{sub 2}-SE is insensitive to the presence of various dissolved ions including Cl{sup -}, Li{sup +}, SO{sub 4}{sup 2-}, NO{sup 3-}, Ca{sup 2+}, PO{sub 4}{sup 3-}, Mg{sup 2+}, Na{sup +} and K{sup +} within a concentration range of 10{sup -7} to 10{sup -1} mol/L for DO measurement from 0.5 to 8.0 ppm in the test solution at a temperature range of 11-30 deg. C. These dissolved salts had practically no effect on the sensor's output potential difference response, whereas Br{sup -} ions had some effects at concentration more than 10{sup -3} mol/L. The relationship between DO and the sensor's potential difference was found to be relatively linear with the maximum sensitivity of -50.6 mV per decade was achieved at 20 mol% ZnO at 7.35 pH. The response and recovery time to pH changes for the planar device based on 20 mol% ZnO-RuO{sub 2}-SE was found to be 10 and 25 s

  6. Scalable Electrophysiology in Intact Small Animals with Nanoscale Suspended Electrode Arrays

    OpenAIRE

    Gonzales, Daniel L.; Badhiwala, Krishna N.; Vercosa, Daniel G.; Avants, Ben W.; Liu, Zheng; Zhong, Weiwei; Robinson, Jacob T.

    2017-01-01

    Electrical measurements from large populations of animals would help reveal fundamental properties of the nervous system and neurological diseases. Small invertebrates are ideal for these large-scale studies; however, patch-clamp electrophysiology in microscopic animals typically requires low-throughput and invasive dissections. To overcome these limitations, we present nano-SPEARs: suspended electrodes integrated into a scalable microfluidic device. Using this technology, we have made the fi...

  7. Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings

    Science.gov (United States)

    Patel, Paras R.; Na, Kyounghwan; Zhang, Huanan; Kozai, Takashi D. Y.; Kotov, Nicholas A.; Yoon, Euisik; Chestek, Cynthia A.

    2016-01-01

    Objective Single carbon fiber electrodes (d=8.4 μm) insulated with parylene-c and functionalized with PEDOT:pTS have been shown to record single unit activity but manual implantation of these devices with forceps can be difficult. Without an improvement in the insertion method any increase in the channel count by fabricating carbon fiber arrays would be impractical. In this study, we utilize a water soluble coating and structural backbones that allow us to create, implant, and record from fully functionalized arrays of carbon fibers with ~150 μm pitch. Approach Two approaches were tested for the insertion of carbon fiber arrays. The first method used a PEG coating that temporarily stiffened the fibers while leaving a small portion at the tip exposed. The small exposed portion (500 μm – 1 mm) readily penetrated the brain allowing for an insertion that did not require the handling of each fiber by forceps. The second method involved the fabrication of silicon support structures with individual shanks spaced 150 μm apart. Each shank consisted of a small groove that held an individual carbon fiber. Main results Our results showed that the PEG coating allowed for the chronic implantation of carbon fiber arrays in 5 rats with unit activity detected at 31 days post-implant. The silicon support structures recorded single unit activity in 3 acute rat surgeries. In one of those surgeries a stacked device with 3 layers of silicon support structures and carbon fibers was built and shown to readily insert into the brain with unit activity on select sites. Significance From these studies we have found that carbon fibers spaced at ~150 μm readily insert into the brain. This greatly increases the recording density of chronic neural probes and paves the way for even higher density devices that have a minimal scarring response. PMID:26035638

  8. All-diamond functional surface micro-electrode arrays for brain-slice neural analysis

    Czech Academy of Sciences Publication Activity Database

    Vahidpour, F.; Curley, L.; Biró, I.; McDonald, M.; Croux, D.; Pobedinskas, P.; Haenen, K.; Giugliano, M.; Vlčková Živcová, Zuzana; Kavan, Ladislav; Nesládek, M.

    2017-01-01

    Roč. 214, č. 2 (2017), č. článku 1532347. ISSN 1862-6300 R&D Projects: GA ČR GA13-31783S Institutional support: RVO:61388955 Keywords : impedance spectroscopy * microelectrode arrays * surface termination Subject RIV: CG - Electrochemistry OBOR OECD: Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis) Impact factor: 1.775, year: 2016

  9. Black, Hairy Tongue

    Science.gov (United States)

    ... on the surface of the tongue that contain taste buds. These papillae, which are longer than normal, can easily trap and be stained by bacteria, yeast, tobacco, food or other ... tongue Altered taste or metallic taste in your mouth Bad breath ( ...

  10. Ti@δ-MnO_2 core-shell nanowire arrays as self-supported electrodes of supercapacitors and Li ion batteries

    International Nuclear Information System (INIS)

    Zhao, Guangyu; Zhang, Dong; Zhang, Li; Sun, Kening

    2016-01-01

    Highlights: • Ti@δ-MnO_2 core-shell nanowire arrays prepared by a electrochemical method. • Remarkable rate capability as both Li ion battery and supercapacitor electrodes. • Good electronic conductivity and facilitated mass transport. - Abstract: δ-MnO_2 is a promissing electrode material of supercapacitors and Li ion batteries (LIBs) owing to its low cost, layer structure and composite valence of Mn. However, the unfavorable electronic conductivity of δ-MnO_2 restricts its rate capability in both of the two devices. Herein, a vertically standing Ti nanowire array modified with δ-MnO_2 nanoflakes is prepared by a electrodeposition method, and the electrochemical properties of Ti@δ-MnO_2 nanowire arrays in supercapacitors and LIBs are investigated. The results show that, the arrays have a capacity of 195 F g"−"1 at 1.0 A g"−"1 and can cycle more than 10000 rounds at 10 A g"−"1 as electrodes of supercapacitors. On the other hand, the arrays behave good rate capability as LIB cathodes, which can release a capacity of 70 mAh g"−"1 at 10C rate charge/discharge. We suggest that, the good electronic conductivity owing to the core-shell structure and the facilitated mass transport supplied by the array architecture are responsible for the enhanced rate performances in the two devices.

  11. An array of highly flexible electrodes with a tailored configuration locked by gelatin during implantation – initial evaluation in cortex cerebri of awake rats

    Directory of Open Access Journals (Sweden)

    Johan eAgorelius

    2015-09-01

    Full Text Available A major challenge in the field of neural interfaces is to overcome the problem of poor stability of neuronal recordings, which impedes long-term studies of individual neurons in the brain. Conceivably, unstable recordings reflect relative movements between electrode and tissue. To address this challenge, we have developed a new ultra-flexible electrode array and evaluated its performance in awake non-restrained animals.MethodsAn array of eight separated gold leads (4 x10 μm, individually flexible in 3D, were cut from a gold sheet using laser milling and insulated with Parylene C. To provide structural support during implantation into rat cortex, the electrode array was embedded in a hard gelatin based material, which dissolves after implantation. Recordings were made during 3 weeks. At termination, the animals were perfused with fixative and frozen to prevent dislocation of the implanted electrodes. A thick slice of brain tissue, with the electrode array still in situ, was made transparent using methyl salicylate to evaluate the conformation of the implanted electrode array.ResultsMedian noise levels and signal/noise remained relatively stable during the 3 week observation period; 4.3 μV to 5.9 μV and 2.8 to 4.2, respectively. The spike amplitudes were often quite stable within recording sessions and for 15% of recordings where single-units were identified, the highest-SNR unit had an amplitude higher than 150 V. In addition, high correlations (>0.96 between unit waveforms recorded at different time points were obtained for 58% of the electrode sites. The structure of the electrode array was well preserved 3 weeks after implantation.Conclusions A new implantable multichannel neural interface, comprising electrodes individually flexible in 3D that retain its architecture and functionality after implantation has been developed. Since the new neural interface design is adaptable, it offers a versatile tool to explore the function of various

  12. Development and Characterization of a Diamond-Insulated Graphitic Multi Electrode Array Realized with Ion Beam Lithography

    Directory of Open Access Journals (Sweden)

    Federico Picollo

    2014-12-01

    Full Text Available The detection of quantal exocytic events from neurons and neuroendocrine cells is a challenging task in neuroscience. One of the most promising platforms for the development of a new generation of biosensors is diamond, due to its biocompatibility, transparency and chemical inertness. Moreover, the electrical properties of diamond can be turned from a perfect insulator into a conductive material (resistivity ~mΩ·cm by exploiting the metastable nature of this allotropic form of carbon. A 16‑channels MEA (Multi Electrode Array suitable for cell culture growing has been fabricated by means of ion implantation. A focused 1.2 MeV He+ beam was scanned on a IIa single-crystal diamond sample (4.5 × 4.5 × 0.5 mm3 to cause highly damaged sub-superficial structures that were defined with micrometric spatial resolution. After implantation, the sample was annealed. This process provides the conversion of the sub-superficial highly damaged regions to a graphitic phase embedded in a highly insulating diamond matrix. Thanks to a three-dimensional masking technique, the endpoints of the sub-superficial channels emerge in contact with the sample surface, therefore being available as sensing electrodes. Cyclic voltammetry and amperometry measurements of solutions with increasing concentrations of adrenaline were performed to characterize the biosensor sensitivity. The reported results demonstrate that this new type of biosensor is suitable for in vitro detection of catecholamine release.

  13. Commercialisation of CMOS Integrated Circuit Technology in Multi-Electrode Arrays for Neuroscience and Cell-Based Biosensors

    Directory of Open Access Journals (Sweden)

    Chris R. Bowen

    2011-05-01

    Full Text Available The adaptation of standard integrated circuit (IC technology as a transducer in cell-based biosensors in drug discovery pharmacology, neural interface systems and electrophysiology requires electrodes that are electrochemically stable, biocompatible and affordable. Unfortunately, the ubiquitous Complementary Metal Oxide Semiconductor (CMOS IC technology does not meet the first of these requirements. For devices intended only for research, modification of CMOS by post-processing using cleanroom facilities has been achieved. However, to enable adoption of CMOS as a basis for commercial biosensors, the economies of scale of CMOS fabrication must be maintained by using only low-cost post-processing techniques. This review highlights the methodologies employed in cell-based biosensor design where CMOS-based integrated circuits (ICs form an integral part of the transducer system. Particular emphasis will be placed on the application of multi-electrode arrays for in vitro neuroscience applications. Identifying suitable IC packaging methods presents further significant challenges when considering specific applications. The various challenges and difficulties are reviewed and some potential solutions are presented.

  14. Gold nanoparticle arrays directly grown on nanostructured indium tin oxide electrodes: Characterization and electroanalytical application

    International Nuclear Information System (INIS)

    Zhang Jingdong; Oyama, Munetaka

    2005-01-01

    This work describes an improved seed-mediated growth approach for the direct attachment and growth of mono-dispersed gold nanoparticles on nanostructured indium tin oxide (ITO) surfaces. It was demonstrated that, when the seeding procedure of our previously reported seed-mediated growth process on an ITO surface was modified, the density of gold nanospheres directly grown on the surface could be highly improved, while the emergence of nanorods was restrained. By field emission scanning electron microscopy (FE-SEM) and cyclic voltammetry, the growth of gold nanoparticles with increasing growth time on the defect sites of nanostructured ITO surface was monitored. Using a [Fe(China) 6 ] 3- /[Fe(China) 6 ] 4- redox probe, the increasingly facile heterogeneous electron transfer kinetics resulting from the deposition and growth of gold nanoparticle arrays was observed. The as-prepared gold nanoparticle arrays exhibited high catalytic activity toward the electrooxidation of nitric oxide, which could provide electroanalytical application for nitric oxide sensing

  15. High optical transmittance of aluminum ultrathin film with hexagonal nanohole arrays as transparent electrode

    KAUST Repository

    Du, Qing Guo; Yue, Weisheng; Wang, Zhihong; Lau, Wah Tung; Ren, Hengjiang; Li, Er-Ping

    2016-01-01

    We fabricate samples of aluminum ultrathin films with hexagonal nanohole arrays and characterize the transmission performance. High optical transmittance larger than 60% over a broad wavelength range from 430 nm to 750 nm is attained experimentally. The Fano-type resonance of the excited surface plasmon plaritons and the directly transmitted light attribute to both of the broadband transmission enhancement and the transmission suppression dips. © 2016 Optical Society of America.

  16. High optical transmittance of aluminum ultrathin film with hexagonal nanohole arrays as transparent electrode

    KAUST Repository

    Du, Qing Guo

    2016-02-24

    We fabricate samples of aluminum ultrathin films with hexagonal nanohole arrays and characterize the transmission performance. High optical transmittance larger than 60% over a broad wavelength range from 430 nm to 750 nm is attained experimentally. The Fano-type resonance of the excited surface plasmon plaritons and the directly transmitted light attribute to both of the broadband transmission enhancement and the transmission suppression dips. © 2016 Optical Society of America.

  17. Fabrication process for CMUT arrays with polysilicon electrodes, nanometre precision cavity gaps and through-silicon vias

    International Nuclear Information System (INIS)

    Due-Hansen, J; Poppe, E; Summanwar, A; Jensen, G U; Breivik, L; Wang, D T; Schjølberg-Henriksen, K; Midtbø, K

    2012-01-01

    Capacitive micromachined ultrasound transducers (CMUTs) can be used to realize miniature ultrasound probes. Through-silicon vias (TSVs) allow for close integration of the CMUT and read-out electronics. A fabrication process enabling the realization of a CMUT array with TSVs is being developed. The integrated process requires the formation of highly doped polysilicon electrodes with low surface roughness. A process for polysilicon film deposition, doping, CMP, RIE and thermal annealing that resulted in a film with sheet resistance of 4.0 Ω/□ and a surface roughness of 1 nm rms has been developed. The surface roughness of the polysilicon film was found to increase with higher phosphorus concentrations. The surface roughness also increased when oxygen was present in the thermal annealing ambient. The RIE process for etching CMUT cavities in the doped polysilicon gave a mean etch depth of 59.2 ± 3.9 nm and a uniformity across the wafer ranging from 1.0 to 4.7%. The two presented processes are key processes that enable the fabrication of CMUT arrays suitable for applications in for instance intravascular cardiology and gastrointestinal imaging. (paper)

  18. Cantilever-type electrode array-based high-throughput microparticle sorting platform driven by gravitation and negative dielectrophoretic force

    International Nuclear Information System (INIS)

    Kim, Youngho; Kim, Byungkyu; Lee, Junghun; Kim, Younggeun; Shin, Sang-Mo

    2011-01-01

    In this paper, we describe a cantilever-type electrode (CE) array-based high-throughput sorting platform, which is a tool used to separate microparticles using gravitation and negative dielectrophoretic (n-DEP) force. This platform consists of meso-size channels and a CE array, which is designed to separate a large number of target particles by differences in their dielectric material properties (DMP) and the weight of the particles. We employ a two-step separation process, with sedimentation as the first step and n-DEP as the second step. In order to differentiate the weight and the DMP of each particle, we employ the sedimentation phenomena in a vertical channel and the CE-based n-DEP in an inclined channel. By using three kinds of polystyrene beads with diameters of 10, 25 and 50 µm, the optimal population (10 7 beads ml −1 ) of particles and the appropriate length (25 mm) of the vertical channel for high performance were determined experimentally. Conclusively, by combining sedimentation and n-DEP schemes, we achieve 74.5, 94.7 and 100% separation efficiency for sorting microparticles with a diameter of 10, 25 and 50 µm, respectively.

  19. Algorithm for real-time detection of signal patterns using phase synchrony: an application to an electrode array

    Science.gov (United States)

    Sadeghi, Saman; MacKay, William A.; van Dam, R. Michael; Thompson, Michael

    2011-02-01

    Real-time analysis of multi-channel spatio-temporal sensor data presents a considerable technical challenge for a number of applications. For example, in brain-computer interfaces, signal patterns originating on a time-dependent basis from an array of electrodes on the scalp (i.e. electroencephalography) must be analyzed in real time to recognize mental states and translate these to commands which control operations in a machine. In this paper we describe a new technique for recognition of spatio-temporal patterns based on performing online discrimination of time-resolved events through the use of correlation of phase dynamics between various channels in a multi-channel system. The algorithm extracts unique sensor signature patterns associated with each event during a training period and ranks importance of sensor pairs in order to distinguish between time-resolved stimuli to which the system may be exposed during real-time operation. We apply the algorithm to electroencephalographic signals obtained from subjects tested in the neurophysiology laboratories at the University of Toronto. The extension of this algorithm for rapid detection of patterns in other sensing applications, including chemical identification via chemical or bio-chemical sensor arrays, is also discussed.

  20. Isometric and swallowing tongue strength in healthy adults.

    Science.gov (United States)

    Todd, J Tee; Lintzenich, Catherine Rees; Butler, Susan G

    2013-10-01

    The tongue contributes to a safe swallow. It facilitates bolus control during mastication, maintains a bolus in the oral cavity to prevent premature entry of the bolus into the hypopharynx, and helps generate pressure in the hypopharynx during swallowing. This study examined isometric tongue strength and tongue pressure measured during swallowing in healthy young and older adults. Prospective group design. One hundred twenty-six healthy individuals who were recruited as part of a larger study on swallowing participated in this study. Participants were divided into three age groups: 20 to 40 years, 41 to 60 years, and ≥61 years. A KayPentax Digital Swallowing Workstation with an air-filled bulb array was placed on the tongue of each participant (anterior to posterior). Participants completed three isometric tongue presses and three swallows. Repeated measures analyses of variance revealed a significant main effect of age (P = .01) and gender by tongue bulb location interaction (P = .02) for isometric tongue strength. That is, older adults had lower isometric tongue strength than young adults, and females had a greater difference between anterior and posterior tongue strength than males. Tongue strength during swallowing yielded significantly greater anterior versus posterior tongue pressure. This study comprises one of the largest in terms of number of healthy participants reported to date and confirms previous findings that isometric tongue strength decreases with age. Furthermore, given young and older adults generate similar swallowing pressures, swallowing is a submaximal strength activity, yet older adults have less functional reserve. 4. Copyright © 2013 The American Laryngological, Rhinological, and Otological Society, Inc.

  1. Preparation of CuInS{sub 2}/TiO{sub 2} nanotube heterojunction arrays electrode and investigation of its photoelectrochemical properties

    Energy Technology Data Exchange (ETDEWEB)

    Li, Tingting [School of Environmental Science and Technology, State Key Laboratory of Fine Chemical, Key Laboratory of Industrial Ecology and Environmental Engineering of Ministry of Education, Dalian University of Technology, Dalian 116024, Liaoning (China); College of Civil Engineering and Architecture, Liaoning Technical University, Fuxin 123000 (China); Li, Xinyong, E-mail: xyli@dlut.edu.cn [School of Environmental Science and Technology, State Key Laboratory of Fine Chemical, Key Laboratory of Industrial Ecology and Environmental Engineering of Ministry of Education, Dalian University of Technology, Dalian 116024, Liaoning (China); Zhao, Qidong; Teng, Wei [School of Environmental Science and Technology, State Key Laboratory of Fine Chemical, Key Laboratory of Industrial Ecology and Environmental Engineering of Ministry of Education, Dalian University of Technology, Dalian 116024, Liaoning (China)

    2014-11-15

    Graphical abstract: Schematic illustration of the synthesis steps of CuInS{sub 2}/TiO{sub 2} heterojunction arrays electrode. - Highlights: • CuInS{sub 2}/TiO{sub 2} nanotube heterojunction arrays electrode was successfully fabricated via a modified SILAR method. • Morphology, chemical compositions and the photoelectrochemical properties were studied. • The formed heterojunction structure is demonstrated as n–n type heterojunction. - Abstract: CuInS{sub 2}/TiO{sub 2} nanotube heterojunction arrays electrode was synthesized via a modified successive ionic layer adsorption and reaction (SILAR) method. The morphology, crystalline structure and chemical composition of the composite electrode were characterized with field-emission scanning electron microscopy (SEM), X-ray diffraction (XRD) and X-ray photoelectron spectra (XPS), respectively. The optical properties were investigated by UV–vis diffusion reflection spectra (DRS) and photoluminescence (PL) spectra as well as the photoelectrochemical measurements. Significantly enhanced photoelectrochemical properties of CuInS{sub 2}/TiO{sub 2} NTs electrode were observed under visible light irradiation, which could be attributed to the high absorption coefficient of CuInS{sub 2} in visible region and the heterostructure formed between CuInS{sub 2} and TiO{sub 2}.

  2. Effects of Nanowire Length and Surface Roughness on the Electrochemical Sensor Properties of Nafion-Free, Vertically Aligned Pt Nanowire Array Electrodes

    Directory of Open Access Journals (Sweden)

    Zhiyang Li

    2015-09-01

    Full Text Available In this paper, vertically aligned Pt nanowire arrays (PtNWA with different lengths and surface roughnesses were fabricated and their electrochemical performance toward hydrogen peroxide (H2O2 detection was studied. The nanowire arrays were synthesized by electroplating Pt in nanopores of anodic aluminum oxide (AAO template. Different parameters, such as current density and deposition time, were precisely controlled to synthesize nanowires with different surface roughnesses and various lengths from 3 μm to 12 μm. The PtNWA electrodes showed better performance than the conventional electrodes modified by Pt nanowires randomly dispersed on the electrode surface. The results indicate that both the length and surface roughness can affect the sensing performance of vertically aligned Pt nanowire array electrodes. Generally, longer nanowires with rougher surfaces showed better electrochemical sensing performance. The 12 μm rough surface PtNWA presented the largest sensitivity (654 μA·mM−1·cm−2 among all the nanowires studied, and showed a limit of detection of 2.4 μM. The 12 μm rough surface PtNWA electrode also showed good anti-interference property from chemicals that are typically present in the biological samples such as ascorbic, uric acid, citric acid, and glucose. The sensing performance in real samples (river water was tested and good recovery was observed. These Nafion-free, vertically aligned Pt nanowires with surface roughness control show great promise as versatile electrochemical sensors and biosensors.

  3. Interpretation of field potentials measured on a multi electrode array in pharmacological toxicity screening on primary and human pluripotent stem cell-derived cardiomyocytes

    NARCIS (Netherlands)

    Tertoolen, L.G.J.; Braam, S. R.; van Meer, B.J.; Passier, R.; Mummery, C. L.

    2018-01-01

    Multi electrode arrays (MEAs) are increasingly used to detect external field potentials in electrically active cells. Recently, in combination with cardiomyocytes derived from human (induced) pluripotent stem cells they have started to become a preferred tool to examine newly developed drugs for

  4. Comparison of the HiFocus Mid-Scala and HiFocus 1J Electrode Array: Angular Insertion Depths and Speech Perception Outcomes.

    Science.gov (United States)

    van der Jagt, M Annerie; Briaire, Jeroen J; Verbist, Berit M; Frijns, Johan H M

    2016-01-01

    The HiFocus Mid-Scala (MS) electrode array has recently been introduced onto the market. This precurved design with a targeted mid-scalar intracochlear position pursues an atraumatic insertion and optimal distance for neural stimulation. In this study we prospectively examined the angular insertion depth achieved and speech perception outcomes resulting from the HiFocus MS electrode array for 6 months after implantation, and retrospectively compared these with the HiFocus 1J lateral wall electrode array. The mean angular insertion depth within the MS population (n = 96) was found at 470°. This was 50° shallower but more consistent than the 1J electrode array (n = 110). Audiological evaluation within a subgroup, including only postlingual, unilaterally implanted, adult cochlear implant recipients who were matched on preoperative speech perception scores and the duration of deafness (MS = 32, 1J = 32), showed no difference in speech perception outcomes between the MS and 1J groups. Furthermore, speech perception outcome was not affected by the angular insertion depth or frequency mismatch. © 2016 S. Karger AG, Basel.

  5. Three-dimensional electrodes for dye-sensitized solar cells: synthesis of indium-tin-oxide nanowire arrays and ITO/TiO2 core-shell nanowire arrays by electrophoretic deposition

    International Nuclear Information System (INIS)

    Wang, H-W; Ting, C-F; Hung, M-K; Chiou, C-H; Liu, Y-L; Liu Zongwen; Ratinac, Kyle R; Ringer, Simon P

    2009-01-01

    Dye-sensitized solar cells (DSSCs) show promise as a cheaper alternative to silicon-based photovoltaics for specialized applications, provided conversion efficiency can be maximized and production costs minimized. This study demonstrates that arrays of nanowires can be formed by wet-chemical methods for use as three-dimensional (3D) electrodes in DSSCs, thereby improving photoelectric conversion efficiency. Two approaches were employed to create the arrays of ITO (indium-tin-oxide) nanowires or arrays of ITO/TiO 2 core-shell nanowires; both methods were based on electrophoretic deposition (EPD) within a polycarbonate template. The 3D electrodes for solar cells were constructed by using a doctor-blade for coating TiO 2 layers onto the ITO or ITO/TiO 2 nanowire arrays. A photoelectric conversion efficiency as high as 4.3% was achieved in the DSSCs made from ITO nanowires; this performance was better than that of ITO/TiO 2 core-shell nanowires or pristine TiO 2 films. Cyclic voltammetry confirmed that the reaction current was significantly enhanced when a 3D ITO-nanowire electrode was used. Better separation of charge carriers and improved charge transport, due to the enlarged interfacial area, are thought to be the major advantages of using 3D nanowire electrodes for the optimization of DSSCs.

  6. Influence of Experimental Conditions on Electronic Tongue Results—Case of Valsartan Minitablets Dissolution

    Directory of Open Access Journals (Sweden)

    Małgorzata Wesoły

    2016-08-01

    Full Text Available A potentiometric electronic tongue was applied to study the release of valsartan from pharmaceutical formulations, i.e., minitablets uncoated and coated with Eudragit E. Special attention was paid to evaluate the influence of medium temperature and composition, as well as to compare the performances of the sensor arrays working in various hydrodynamic conditions. The drug dissolution profiles registered with the ion-sensitive electrodes were compared with standard dissolution tests performed with USP Apparatus 2 (paddle. Moreover, the signal changes of all sensors were processed by principal component analysis to visualize the release modifications, related to the presence of the coating agent. Finally, the importance and influence of the experimental conditions on the results obtained using potentiometric sensor arrays were discussed.

  7. In situ synthesis of oriented NiS nanotube arrays on FTO as high-performance counter electrode for dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yan, E-mail: liyan-nwnu@163.com [Key Laboratory of Atomic and Molecular Physics & Functional Materials of Gansu Province, College of Physics and Electronic Engineering, Northwest Normal University, Lanzhou, 730070 (China); Chang, Yin [Key Laboratory of Atomic and Molecular Physics & Functional Materials of Gansu Province, College of Physics and Electronic Engineering, Northwest Normal University, Lanzhou, 730070 (China); Zhao, Yun [Laboratory of Clean Energy Chemistry and Materials, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou, 730000 (China); Wang, Jian; Wang, Cheng-wei [Key Laboratory of Atomic and Molecular Physics & Functional Materials of Gansu Province, College of Physics and Electronic Engineering, Northwest Normal University, Lanzhou, 730070 (China)

    2016-09-15

    Oriented nickel sulfide (NiS) nanotube arrays were successfully in-situ fabricated on conductive glass substrate and used directly as counter electrode for dye-sensitized solar cells without any post-processing. Compared with Pt counter electrode, for the beneficial effect of electronic transport along the axial direction through the arrays to the substrate, oriented NiS nanotube arrays exhibit both higher electrocatalytic activity for I{sub 3}{sup −} reduction and better electrochemical stability, resulting in a significantly improved power conversion efficiency of 9.8%. Such in-situ grown oriented sulfide semiconductor nanotube arrays is expected to lead a new class structure of composites for highly efficient cathode materials. - Highlights: • In-situ synthesis strategy was proposed to construct oriented NiS nanotube arrays. • Such oriented tube nanostructure benefits the electronic transport along the axial direction of the arrays. • As CE of DSSCs, NiS nanotube arrays exhibit both higher efficiency (9.8%) and electrochemical stability than Pt.

  8. Boronate-Modified Interdigitated Electrode Array for Selective Impedance-Based Sensing of Glycated Hemoglobin

    DEFF Research Database (Denmark)

    Boonyasit, Yuwadee; Laiwattanapaisal, Wanida; Chailapakul, Orawon

    2016-01-01

    An impedance-based label-free affinity sensor was developed for the recognition of glycated hemoglobin (HbA1c). Interdigitated gold microelectrode arrays (IDA) were first modified with a self-assembled monolayer of cysteamine followed by cross-linking with glutaraldehyde and subsequent binding of 3......-aminophenylboronic acid (APBA), which selectively binds HbA1c via cis-diol interactions. Impedance sensing was demonstrated to be highly responsive to the clinically relevant HbA1c levels (0.1%-8.36%) with a detection limit of 0.024% (3σ). The specificity of the assay was evaluated with non-glycated hemoglobin (Hb...

  9. Discrimination of Rice with Different Pretreatment Methods by Using a Voltammetric Electronic Tongue

    Directory of Open Access Journals (Sweden)

    Li Wang

    2015-07-01

    Full Text Available In this study, an application of a voltammetric electronic tongue for discrimination and prediction of different varieties of rice was investigated. Different pretreatment methods were selected, which were subsequently used for the discrimination of different varieties of rice and prediction of unknown rice samples. To this aim, a voltammetric array of sensors based on metallic electrodes was used as the sensing part. The different samples were analyzed by cyclic voltammetry with two sample-pretreatment methods. Discriminant Factorial Analysis was used to visualize the different categories of rice samples; however, radial basis function (RBF artificial neural network with leave-one-out cross-validation method was employed for prediction modeling. The collected signal data were first compressed employing fast Fourier transform (FFT and then significant features were extracted from the voltammetric signals. The experimental results indicated that the sample solutions obtained by the non-crushed pretreatment method could efficiently meet the effect of discrimination and recognition. The satisfactory prediction results of voltammetric electronic tongue based on RBF artificial neural network were obtained with less than five-fold dilution of the sample solution. The main objective of this study was to develop primary research on the application of an electronic tongue system for the discrimination and prediction of solid foods and provide an objective assessment tool for the food industry.

  10. A flexible electrode array for muscle impedance measurements in the mouse hind limb: A tool to speed research in neuromuscular disease

    International Nuclear Information System (INIS)

    Li, J; Rutkove, S B

    2013-01-01

    Electrical impedance myography (EIM) is a bioelectrical impedance technique focused on the assessment of neuromuscular diseases using tetrapolar surface arrays. Recently, we have shown that reproducible and sensitive EIM measurements can be made on the gastrocnemius muscle of the mouse hind limb and that these are sensitive to disease alterations. A dedicated array would help speed data acquisition and provide additional sensitivity to disease-induced alterations. A flexible electrode array was developed with electrode sizes of 1mm × 1mm by Parlex, Inc. Tetrapolar electrode sets were arranged both parallel to (longitudinal) and orthogonally to (transverse) the major muscle fiber direction of the gastrocnemius muscle. Measurements were made with a dedicated EIM system. A total of 11 healthy animals and 7 animals with spinal muscular atrophy (a form of motor neuron disease) were evaluated after the fur was completely removed with a depilatory agent from the hind limb. Standard electrophysiologic testing (compound motor action potential amplitude and motor unit number estimation) was also performed. The flexible electrode array demonstrated high repeatability in both the longitudinal and transverse directions in the healthy and diseased animals (with intraclass correlation coefficients of 0.94 and 0.89, respectively, for phase angle measured transversely). In addition, differences between healthy and diseased animals were identifiable. For example, the 50 kHz transverse phase angle was higher in the healthy as compared to the SMA animals (16.8° ± 0.5 vs. 14.3° ± 0.7, respectively) at 21 weeks of age (p = 0.01). Differences in anisotropy were also identifiable. Correlations to several standard neurophysiologic parameters also appeared promising. This novel flexible tetrapolar electrode array can be used on the mouse hind limb and provides multidirectional data that can be used to assess muscle health. This technique has the potential of finding widespread use in

  11. A flexible electrode array for muscle impedance measurements in the mouse hind limb: A tool to speed research in neuromuscular disease

    Science.gov (United States)

    Li, J.; Rutkove, S. B.

    2013-04-01

    Electrical impedance myography (EIM) is a bioelectrical impedance technique focused on the assessment of neuromuscular diseases using tetrapolar surface arrays. Recently, we have shown that reproducible and sensitive EIM measurements can be made on the gastrocnemius muscle of the mouse hind limb and that these are sensitive to disease alterations. A dedicated array would help speed data acquisition and provide additional sensitivity to disease-induced alterations. A flexible electrode array was developed with electrode sizes of 1mm × 1mm by Parlex, Inc. Tetrapolar electrode sets were arranged both parallel to (longitudinal) and orthogonally to (transverse) the major muscle fiber direction of the gastrocnemius muscle. Measurements were made with a dedicated EIM system. A total of 11 healthy animals and 7 animals with spinal muscular atrophy (a form of motor neuron disease) were evaluated after the fur was completely removed with a depilatory agent from the hind limb. Standard electrophysiologic testing (compound motor action potential amplitude and motor unit number estimation) was also performed. The flexible electrode array demonstrated high repeatability in both the longitudinal and transverse directions in the healthy and diseased animals (with intraclass correlation coefficients of 0.94 and 0.89, respectively, for phase angle measured transversely). In addition, differences between healthy and diseased animals were identifiable. For example, the 50 kHz transverse phase angle was higher in the healthy as compared to the SMA animals (16.8° ± 0.5 vs. 14.3° ± 0.7, respectively) at 21 weeks of age (p = 0.01). Differences in anisotropy were also identifiable. Correlations to several standard neurophysiologic parameters also appeared promising. This novel flexible tetrapolar electrode array can be used on the mouse hind limb and provides multidirectional data that can be used to assess muscle health. This technique has the potential of finding widespread use in

  12. Three-dimensional cotton-like nickel nanowire@Ni-Co hydroxide nanosheet arrays as binder-free electrode for high-performance asymmetric supercapacitor

    Science.gov (United States)

    Wan, Houzhao; Li, Lang; Xu, Yang; Tan, Qiuyang; Liu, Xiang; Zhang, Jun; Wang, Hanbin; Wang, Hao

    2018-05-01

    Three-dimensional (3D) cotton-like Ni-Co layered double hydroxide nanosheet arrays/nickel nanowires (3D Ni-Co LDH/NiNw) were successfully fabricated through a facile chemical bath deposition method. The 3D nickel nanowires are used as a conductive substrate with robust adhesion for high-pseudocapacitance Ni-Co LDH. The 3D Ni-Co LDH/NiNw electrode shows a high areal specific capacitance of 14 F cm-2 at 5 mA cm-2 and quality specific capacitance of 466.6 F g-1 at 0.125 A g-1 with respect to the whole quality of the electrode. The fabricated asymmetric supercapacitor exhibits a remarkable energy density of 0.387 mWh cm-2 using Ni-Co LDH/NiNw as the negative electrode. This high-performance composite electrode presents a new and affordable general approach for supercapacitors.

  13. The Tongue and Quill

    National Research Council Canada - National Science Library

    1997-01-01

    The Tongue and Quill is dedicated to every man and woman in today's twenty-first century Air Force who will ever sling ink at paper, pound a keyboard, give a briefing, or staff a package to support the mission...

  14. Scalable electrophysiology in intact small animals with nanoscale suspended electrode arrays

    Science.gov (United States)

    Gonzales, Daniel L.; Badhiwala, Krishna N.; Vercosa, Daniel G.; Avants, Benjamin W.; Liu, Zheng; Zhong, Weiwei; Robinson, Jacob T.

    2017-07-01

    Electrical measurements from large populations of animals would help reveal fundamental properties of the nervous system and neurological diseases. Small invertebrates are ideal for these large-scale studies; however, patch-clamp electrophysiology in microscopic animals typically requires invasive dissections and is low-throughput. To overcome these limitations, we present nano-SPEARs: suspended electrodes integrated into a scalable microfluidic device. Using this technology, we have made the first extracellular recordings of body-wall muscle electrophysiology inside an intact roundworm, Caenorhabditis elegans. We can also use nano-SPEARs to record from multiple animals in parallel and even from other species, such as Hydra littoralis. Furthermore, we use nano-SPEARs to establish the first electrophysiological phenotypes for C. elegans models for amyotrophic lateral sclerosis and Parkinson's disease, and show a partial rescue of the Parkinson's phenotype through drug treatment. These results demonstrate that nano-SPEARs provide the core technology for microchips that enable scalable, in vivo studies of neurobiology and neurological diseases.

  15. EMG-Torque Relation in Chronic Stroke: A Novel EMG Complexity Representation With a Linear Electrode Array.

    Science.gov (United States)

    Zhang, Xu; Wang, Dongqing; Yu, Zaiyang; Chen, Xiang; Li, Sheng; Zhou, Ping

    2017-11-01

    This study examines the electromyogram (EMG)-torque relation for chronic stroke survivors using a novel EMG complexity representation. Ten stroke subjects performed a series of submaximal isometric elbow flexion tasks using their affected and contralateral arms, respectively, while a 20-channel linear electrode array was used to record surface EMG from the biceps brachii muscles. The sample entropy (SampEn) of surface EMG signals was calculated with both global and local tolerance schemes. A regression analysis was performed between SampEn of each channel's surface EMG and elbow flexion torque. It was found that a linear regression can be used to well describe the relation between surface EMG SampEn and the torque. Each channel's root mean square (RMS) amplitude of surface EMG signal in the different torque level was computed to determine the channel with the highest EMG amplitude. The slope of the regression (observed from the channel with the highest EMG amplitude) was smaller on the impaired side than on the nonimpaired side in 8 of the 10 subjects, regardless of the tolerance scheme (global or local) and the range of torques (full or matched range) used for comparison. The surface EMG signals from the channels above the estimated muscle innervation zones demonstrated significantly lower levels of complexity compared with other channels between innervation zones and muscle tendons. The study provides a novel point of view of the EMG-torque relation in the complexity domain, and reveals its alterations post stroke, which are associated with complex neural and muscular changes post stroke. The slope difference between channels with regard to innervation zones also confirms the relevance of electrode position in surface EMG analysis.

  16. Hierarchical ZnO@MnO2 Core-Shell Pillar Arrays on Ni Foam for Binder-Free Supercapacitor Electrodes

    KAUST Repository

    Huang, Ming; Li, Fei; Zhao, Xiao Li; Luo, Da; You, Xue Qiu; Zhang, Yu Xin; Li, Gang

    2015-01-01

    © 2014 Elsevier Ltd. All rights reserved. Hierarchical ZnO@MnO2 core-shell pillar arrays on Ni foam have been fabricated by a facile two-step hydrothermal approach and further investigated as the binder-free electrode for supercapacitors. The core-shell hybrid nanostructure is achieved by decorating ultrathin self-standing MnO2 nanosheets on ZnO pillar arrays grown radically on Nickel foam. This unique well-designed binder-free electrode exhibits a high specific capacitance (423.5 F g-1 at a current density of 0.5 A g-1), and excellent cycling stability (92% capacitance retention after 3000 cycles). The improved electrochemical results show that the ZnO@MnO2 core-shell nanostructure electrode is promising for high-performance supercapacitors. The facile design of the unique core-shell array architectures provides a new and effective approach to fabricate high-performance binder-free electrode for supercapacitors.

  17. Safety of atrial fibrillation ablation with novel multi-electrode array catheters on uninterrupted anticoagulation-a single-center experience.

    LENUS (Irish Health Repository)

    Hayes, Christopher Ruslan

    2012-02-01

    INTRODUCTION: A recent single-center report indicated that the performance of atrial fibrillation ablation in patients on uninterrupted warfarin using a conventional deflectable tip electrode ablation catheter may be as safe as periprocedural discontinuation of warfarin and bridging with heparin. Novel multi-electrode array catheters for atrial fibrillation ablation are currently undergoing clinical evaluation. While offering the possibility of more rapid atrial fibrillation ablation, they are stiffer and necessitate the deployment of larger deflectable transseptal sheaths, and it remains to be determined if they increase the risk of cardiac perforation and vascular injury. Such potential risks would have implications for a strategy of uninterrupted periprocedural anticoagulation. METHOD AND RESULTS: We audited the safety outcomes of our atrial fibrillation ablation procedures using multi-electrode array ablation catheters in patients on uninterrupted warfarin (CHADS2 score>or=2) and in patients not on warfarin (uninterrupted aspirin). Two bleeding complications occurred in 49 patients on uninterrupted warfarin, both of which were managed successfully without longterm sequelae, and no bleeding complication occurred in 32 patients not on warfarin (uninterrupted aspirin). There were no thromboembolic events or other complication with either anticoagulant regimen. CONCLUSION: Despite the larger diameter and increased stiffness of multi-electrode array catheters and their deflectable transseptal sheaths, their use for catheter ablation in patients with atrial fibrillation on uninterrupted warfarin in this single-center experience does not appear to be unsafe, and thus, an adequately powered multicenter prospective randomized controlled trial should be considered.

  18. Inkjet printing of nanoporous gold electrode arrays on cellulose membranes for high-sensitive paper-like electrochemical oxygen sensors using ionic liquid electrolytes.

    Science.gov (United States)

    Hu, Chengguo; Bai, Xiaoyun; Wang, Yingkai; Jin, Wei; Zhang, Xuan; Hu, Shengshui

    2012-04-17

    A simple approach to the mass production of nanoporous gold electrode arrays on cellulose membranes for electrochemical sensing of oxygen using ionic liquid (IL) electrolytes was established. The approach, combining the inkjet printing of gold nanoparticle (GNP) patterns with the self-catalytic growth of these patterns into conducting layers, can fabricate hundreds of self-designed gold arrays on cellulose membranes within several hours using an inexpensive inkjet printer. The resulting paper-based gold electrode arrays (PGEAs) had several unique properties as thin-film sensor platforms, including good conductivity, excellent flexibility, high integration, and low cost. The porous nature of PGEAs also allowed the addition of electrolytes from the back cellulose membrane side and controllably produced large three-phase electrolyte/electrode/gas interfaces at the front electrode side. A novel paper-based solid-state electrochemical oxygen (O(2)) sensor was therefore developed using an IL electrolyte, 1-butyl-3-methylimidazolium hexafluorophosphate (BMIMPF(6)). The sensor looked like a piece of paper but possessed high sensitivity for O(2) in a linear range from 0.054 to 0.177 v/v %, along with a low detection limit of 0.0075% and a short response time of less than 10 s, foreseeing its promising applications in developing cost-effective and environment-friendly paper-based electrochemical gas sensors.

  19. Development of MATLAB software to control data acquisition from a multichannel systems multi-electrode array.

    Science.gov (United States)

    Messier, Erik

    2016-08-01

    A Multichannel Systems (MCS) microelectrode array data acquisition (DAQ) unit is used to collect multichannel electrograms (EGM) from a Langendorff perfused rabbit heart system to study sudden cardiac death (SCD). MCS provides software through which data being processed by the DAQ unit can be displayed and saved, but this software's combined utility with MATLAB is not very effective. MCSs software stores recorded EGM data in a MathCad (MCD) format, which is then converted to a text file format. These text files are very large, and it is therefore very time consuming to import the EGM data into MATLAB for real-time analysis. Therefore, customized MATLAB software was developed to control the acquisition of data from the MCS DAQ unit, and provide specific laboratory accommodations for this study of SCD. The developed DAQ unit control software will be able to accurately: provide real time display of EGM signals; record and save EGM signals in MATLAB in a desired format; and produce real time analysis of the EGM signals; all through an intuitive GUI.

  20. Co(OH)2/RGO/NiO sandwich-structured nanotube arrays with special surface and synergistic effects as high-performance positive electrodes for asymmetric supercapacitors.

    Science.gov (United States)

    Xu, Han; Zhang, Chi; Zhou, Wen; Li, Gao-Ren

    2015-10-28

    High power density, high energy density and excellent cycling stability are the main requirements for high-performance supercapacitors (SCs) that will be widely used for portable consumer electronics and hybrid electric vehicles. Here we investigate novel types of hybrid Co(OH)2/reduced graphene oxide (RGO)/NiO sandwich-structured nanotube arrays (SNTAs) as positive electrodes for asymmetric supercapacitors (ASCs). The synthesized Co(OH)2/RGO/NiO SNTAs exhibit a significantly improved specific capacity (∼1470 F g(-1) at 5 mV s(-1)) and excellent cycling stability with ∼98% Csp retention after 10 000 cycles because of the fast transport and short diffusion paths for electroactive species, the high utilization rate of electrode materials, and special synergistic effects among Co(OH)2, RGO, and NiO. The high-performance ASCs are assembled using Co(OH)2/RGO/NiO SNTAs as positive electrodes and active carbon (AC) as negative electrodes, and they exhibit a high energy density (115 Wh kg(-1)), a high power density (27.5 kW kg(-1)) and an excellent cycling stability (less 5% Csp loss after 10 000 cycles). This study shows an important breakthrough in the design and fabrication of multi-walled hybrid nanotube arrays as positive electrodes for ASCs.

  1. 3D printed e-tongue

    Science.gov (United States)

    Gaál, Gabriel; da Silva, Tatiana A.; Gaál, Vladimir; Hensel, Rafael C.; Amaral, Lucas R.; Rodrigues, Varlei; Riul, Antonio

    2018-05-01

    Nowadays, one of the biggest issues addressed to electronic sensor fabrication is the build-up of efficient electrodes as an alternative way to the expensive, complex and multistage processes required by traditional techniques. Printed electronics arises as an interesting alternative to fulfill this task due to the simplicity and speed to stamp electrodes on various surfaces. Within this context, the Fused Deposition Modeling 3D printing is an emerging, cost-effective and alternative technology to fabricate complex structures that potentiates several fields with more creative ideas and new materials for a rapid prototyping of devices. We show here the fabrication of interdigitated electrodes using a standard home-made CoreXY 3D printer using transparent and graphene-based PLA filaments. Macro 3D printed electrodes were easily assembled within 6 minutes with outstanding reproducibility. The electrodes were also functionalized with different nanostructured thin films via dip-coating Layer-by-Layer technique to develop a 3D printed e-tongue setup. As a proof of concept, the printed e-tongue was applied to soil analysis. A control soil sample was enriched with several macro-nutrients to the plants (N, P, K, S, Mg and Ca) and the discrimination was done by electrical impedance spectroscopy of water solution of the soil samples. The data was analyzed by Principal Component Analysis and the 3D printed sensor distinguished clearly all enriched samples despite the complexity of the soil chemical composition. The 3D printed e-tongue successfully used in soil analysis encourages further investments in developing new sensory tools for precision agriculture and other fields exploiting the simplicity and flexibility offered by the 3D printing techniques.

  2. Tongue motor training support system.

    Science.gov (United States)

    Sasaki, Makoto; Onishi, Kohei; Nakayama, Atsushi; Kamata, Katsuhiro; Stefanov, Dimitar; Yamaguchi, Masaki

    2014-01-01

    In this paper, we introduce a new tongue-training system that can be used for improvement of the tongue's range of motion and muscle strength after dysphagia. The training process is organized in game-like manner. Initially, we analyzed surface electromyography (EMG) signals of the suprahyoid muscles of five subjects during tongue-training motions. This test revealed that four types tongue training motions and a swallowing motion could be classified with 93.5% accuracy. Recognized EMG signals during tongue motions were designed to allow control of a mouse cursor via intentional tongue motions. Results demonstrated that simple PC games could be played by tongue motions, achieving in this way efficient, enjoyable and pleasant tongue training. Using the proposed method, dysphagia patients can choose games that suit their preferences and/or state of mind. It is expected that the proposed system will be an efficient tool for long-term tongue motor training and maintaining patients' motivation.

  3. Selective recurrent laryngeal nerve stimulation using a penetrating electrode array in the feline model.

    Science.gov (United States)

    Haidar, Yarah M; Sahyouni, Ronald; Moshtaghi, Omid; Wang, Beverly Y; Djalilian, Hamid R; Middlebrooks, John C; Verma, Sunil P; Lin, Harrison W

    2017-10-31

    Laryngeal muscles (LMs) are controlled by the recurrent laryngeal nerve (RLN), injury of which can result in vocal fold (VF) paralysis (VFP). We aimed to introduce a bioelectric approach to selective stimulation of LMs and graded muscle contraction responses. Acute experiments in cats. The study included six anesthetized cats. In four cats, a multichannel penetrating microelectrode array (MEA) was placed into an uninjured RLN. For RLN injury experiments, one cat received a standardized hemostat-crush injury, and one cat received a transection-reapproximation injury 4 months prior to testing. In each experiment, three LMs (thyroarytenoid, posterior cricoarytenoid, and cricothyroid muscles) were monitored with an electromyographic (EMG) nerve integrity monitoring system. Electrical current pulses were delivered to each stimulating channel individually. Elicited EMG voltage outputs were recorded for each muscle. Direct videolaryngoscopy was performed for visualization of VF movement. Stimulation through individual channels led to selective activation of restricted nerve populations, resulting in selective contraction of individual LMs. Increasing current levels resulted in rising EMG voltage responses. Typically, activation of individual muscles was successfully achieved via single placement of the MEA by selection of appropriate stimulation channels. VF abduction was predominantly observed on videolaryngoscopy. Nerve histology confirmed injury in cases of RLN crush and transection experiments. We demonstrated the ability of a penetrating MEA to selectively stimulate restricted fiber populations within the feline RLN and selectively elicit contractions of discrete LMs in both acute and injury-model experiments, suggesting a potential role for intraneural MEA implantation in VFP management. NA Laryngoscope, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Human cell-based micro electrode array platform for studying neurotoxicity

    Directory of Open Access Journals (Sweden)

    Laura eYlä-Outinen

    2010-09-01

    Full Text Available At present, most of the neurotoxicological analyses are based on in vitro and in vivo models utilizing animal cells or animal models. In addition, the used in vitro models are mostly based on molecular biological end-point analyses. Thus, for neurotoxicological screening, human cell-based analysis platforms in which the functional neuronal networks responses for various neurotoxicants can be also detected real-time are highly needed. Microelectrode array (MEA is a method which enables the measurement of functional activity of neuronal cell networks in vitro for long periods of time. Here, we utilize MEA to study the neurotoxicity of methyl mercury chloride (MeHgCl, concentrations 0.5-500 nM to human embryonic stem cell (hESC-derived neuronal cell networks exhibiting spontaneous electrical activity. The neuronal cell cultures were matured on MEAs into networks expressing spontaneous spike train-like activity before exposing the cells to MeHgCl for 72 hours. MEA measurements were performed acutely and 24, 48, and 72 hours after the onset of the exposure. Finally, exposed cells were analyzed with traditional molecular biological methods for cell proliferation, cell survival, and gene and protein expression. Our results show that 500 nM MeHgCl decreases the electrical signaling and alters the pharmacologic response of hESC-derived neuronal networks in delayed manner whereas effects can not be detected with qRT-PCR, immunostainings, or proliferation measurements. Thus, we conclude that human cell-based MEA-platform is a sensitive online method for neurotoxicological screening.

  5. Enhanced photoelectrochemical performance of PbS sensitized Sb–SnO{sub 2}/TiO{sub 2} nanotube arrays electrode under visible light illumination

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jia; Tang, Chengli [Department of Environmental Science and Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); Xu, Hao, E-mail: xuhao@mail.xjtu.edu.cn [Department of Environmental Science and Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); Yan, Wei, E-mail: yanwei@mail.xjtu.edu.cn [Department of Environmental Science and Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi’an 710049 (China)

    2015-06-05

    Highlights: • Sb–SnO{sub 2} is used to modify TiO{sub 2} NTAs by microwave method. • PbS is employed to sensitive Sb–SnO{sub 2}/TiO{sub 2} NTAs by S-SILAR method. • Sb–SnO{sub 2} improves electrons transfer and PbS enhances visible light absorption. • The composite electrode shows enhanced photoelectrochemical properties. • The composite electrode exhibits high hydrogen evolution and high QE. - Abstract: The novel PbS sensitized Sb–SnO{sub 2}/TiO{sub 2} nanotube arrays (NTAs) composite electrode (PbS/Sb–SnO{sub 2}/TiO{sub 2} NTAs) was fabricated by microwave combined with sonication-assisted successive ionic layer adsorption and reaction technique (S-SILAR). The obtained electrodes were characterized by field-emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and UV–Vis diffuse reflectance absorption spectra techniques. Enhanced photocurrent (15.52 mA/cm{sup 2}) of the PbS/Sb–SnO{sub 2}/TiO{sub 2} NTAs electrode was observed and can be attributed to the facile photo-generated electrons transfer and enhanced charge separation efficiency. Furthermore, the PbS/Sb–SnO{sub 2}/TiO{sub 2} NTAs composite electrode shows a higher H{sub 2} production rate than the Sb–SnO{sub 2}/TiO{sub 2} NTAs electrode and PbS/TiO{sub 2} NTAs electrode. The results indicate that the PbS/Sb–SnO{sub 2}/TiO{sub 2} NTAs electrode is a promising photoanode in visible photocatalytic water splitting.

  6. An Asymmetric Supercapacitor Based on Activated Porous Carbon Derived from Walnut Shells and NiCo₂O₄ Nanoneedle Arrays Electrodes.

    Science.gov (United States)

    Wang, Wei; Qi, Jiqiu; Sui, Yanwei; He, Yezeng; Meng, Qingkun; Wei, Fuxiang; Jin, Yunxue

    2018-08-01

    A facile method was utilized to convert a common biomass of walnut shells into activated porous carbon by carbonization and activation with nitricacid treatment. The obtained activated carbon (WSs-2) exhibited excellent electrochemical performance with high specific capacitance of 137 F · g-1 at 1 A · g-1 and super cycling performance of 96% capacitance retention at 5 A · g-1 after 5000 cycles. In addition, NiCo2O4 nanoneedle arrays with good electrochemical properties were successfully prepared by a simple hydrothermal method. An aqueous asymmetric supercapacitor (ASC) device based on WSs-2 and NiCo2O4 was assembled, which delivered 21 Wh · kg-1 at a power density of 424.5 W · kg-1, and maintained 19 Wh · kg-1 at power density of 4254 W · kg-1 as well as excellent cycling stability of 99.3% capacitance retention after 5000 cycles at 4 A · g-1. Through this method, low-cost, environmentally friendly and large-scale carbon materials can be fabricated and applied in supercapacitor electrodes.

  7. Droplet Size-Aware and Error-Correcting Sample Preparation Using Micro-Electrode-Dot-Array Digital Microfluidic Biochips.

    Science.gov (United States)

    Li, Zipeng; Lai, Kelvin Yi-Tse; Chakrabarty, Krishnendu; Ho, Tsung-Yi; Lee, Chen-Yi

    2017-12-01

    Sample preparation in digital microfluidics refers to the generation of droplets with target concentrations for on-chip biochemical applications. In recent years, digital microfluidic biochips (DMFBs) have been adopted as a platform for sample preparation. However, there remain two major problems associated with sample preparation on a conventional DMFB. First, only a (1:1) mixing/splitting model can be used, leading to an increase in the number of fluidic operations required for sample preparation. Second, only a limited number of sensors can be integrated on a conventional DMFB; as a result, the latency for error detection during sample preparation is significant. To overcome these drawbacks, we adopt a next generation DMFB platform, referred to as micro-electrode-dot-array (MEDA), for sample preparation. We propose the first sample-preparation method that exploits the MEDA-specific advantages of fine-grained control of droplet sizes and real-time droplet sensing. Experimental demonstration using a fabricated MEDA biochip and simulation results highlight the effectiveness of the proposed sample-preparation method.

  8. Electrophysiological Analysis of human Pluripotent Stem Cell-derived Cardiomyocytes (hPSC-CMs) Using Multi-electrode Arrays (MEAs).

    Science.gov (United States)

    Sala, Luca; Ward-van Oostwaard, Dorien; Tertoolen, Leon G J; Mummery, Christine L; Bellin, Milena

    2017-05-12

    Cardiomyocytes can now be derived with high efficiency from both human embryonic and human induced-Pluripotent Stem Cells (hPSC). hPSC-derived cardiomyocytes (hPSC-CMs) are increasingly recognized as having great value for modeling cardiovascular diseases in humans, especially arrhythmia syndromes. They have also demonstrated relevance as in vitro systems for predicting drug responses, which makes them potentially useful for drug-screening and discovery, safety pharmacology and perhaps eventually for personalized medicine. This would be facilitated by deriving hPSC-CMs from patients or susceptible individuals as hiPSCs. For all applications, however, precise measurement and analysis of hPSC-CM electrical properties are essential for identifying changes due to cardiac ion channel mutations and/or drugs that target ion channels and can cause sudden cardiac death. Compared with manual patch-clamp, multi-electrode array (MEA) devices offer the advantage of allowing medium- to high-throughput recordings. This protocol describes how to dissociate 2D cell cultures of hPSC-CMs to small aggregates and single cells and plate them on MEAs to record their spontaneous electrical activity as field potential. Methods for analyzing the recorded data to extract specific parameters, such as the QT and the RR intervals, are also described here. Changes in these parameters would be expected in hPSC-CMs carrying mutations responsible for cardiac arrhythmias and following addition of specific drugs, allowing detection of those that carry a cardiotoxic risk.

  9. Design of Smart Ion-Selective Electrode Arrays Based on Source Separation through Nonlinear Independent Component Analysis

    Directory of Open Access Journals (Sweden)

    Duarte L.T.

    2014-03-01

    Full Text Available The development of chemical sensor arrays based on Blind Source Separation (BSS provides a promising solution to overcome the interference problem associated with Ion-Selective Electrodes (ISE. The main motivation behind this new approach is to ease the time-demanding calibration stage. While the first works on this problem only considered the case in which the ions under analysis have equal valences, the present work aims at developing a BSS technique that works when the ions have different charges. In this situation, the resulting mixing model belongs to a particular class of nonlinear systems that have never been studied in the BSS literature. In order to tackle this sort of mixing process, we adopted a recurrent network as separating system. Moreover, concerning the BSS learning strategy, we develop a mutual information minimization approach based on the notion of the differential of the mutual information. The method works requires a batch operation, and, thus, can be used to perform off-line analysis. The validity of our approach is supported by experiments where the mixing model parameters were extracted from actual data.

  10. Comparative Analysis of Human and Rodent Brain Primary Neuronal Culture Spontaneous Activity Using Micro-Electrode Array Technology.

    Science.gov (United States)

    Napoli, Alessandro; Obeid, Iyad

    2016-03-01

    Electrical activity in embryonic brain tissue has typically been studied using Micro Electrode Array (MEA) technology to make dozens of simultaneous recordings from dissociated neuronal cultures, brain stem cell progenitors, or brain slices from fetal rodents. Although these rodent neuronal primary culture electrical properties are mostly investigated, it has not been yet established to what extent the electrical characteristics of rodent brain neuronal cultures can be generalized to those of humans. A direct comparison of spontaneous spiking activity between rodent and human primary neurons grown under the same in vitro conditions using MEA technology has never been carried out before and will be described in the present study. Human and rodent dissociated fetal brain neuronal cultures were established in-vitro by culturing on a glass grid of 60 planar microelectrodes neurons under identical conditions. Three different cultures of human neurons were produced from tissue sourced from a single aborted fetus (at 16-18 gestational weeks) and these were compared with seven different cultures of embryonic rat neurons (at 18 gestational days) originally isolated from a single rat. The results show that the human and rodent cultures behaved significantly differently. Whereas the rodent cultures demonstrated robust spontaneous activation and network activity after only 10 days, the human cultures required nearly 40 days to achieve a substantially weaker level of electrical function. These results suggest that rat neuron preparations may yield inferences that do not necessarily transfer to humans. © 2015 Wiley Periodicals, Inc.

  11. In-situ growth of ZnO nanowire arrays on the sensing electrode via a facile hydrothermal route for high-performance NO2 sensor

    Science.gov (United States)

    Chen, Xiangxiang; Shen, Yanbai; Zhang, Wei; Zhang, Jin; Wei, Dezhou; Lu, Rui; Zhu, Lijia; Li, Hansen; Shen, Yansong

    2018-03-01

    ZnO nanowire (ZNW) arrays were in-situ grown on the sensing electrode via a facile hydrothermal route for NO2 sensing application. ZNW arrays were prepared by a seed layer deposition on the surface of the sensing electrode using a dipping process in a Zn(CH3COO)2·2H2O ethanol solution followed by a seed growth using a hydrothermal route in the Zn(NO3)2·6H2O-HMTA (C6H12N4) system. The microstructural characterizations of the ZNW arrays by means of XRD, FESEM, TEM, FTIR and XPS showed that ZnO nanowires with the diameters of 80-90 nm and the lengths of 0.6-1 μm had a single crystal hexagonal wurtzite structure. Gas sensing properties demonstrated the response of the sensor based on the ZNW arrays was linearly proportional to the NO2 concentration in the range of 1-30 ppm with good reproducibility and selectivity. The maximum sensor response to NO2 was obtained at an operating temperature of 250 °C. The response and recovery times reduced rapidly with increasing the operating temperature. The growth mechanism and sensing mechanism of the ZNW arrays were discussed in accordance with the deposition of the seed layer and the modulation of the depletion layer, respectively.

  12. The influence of tongue strength on oral viscosity discrimination acuity.

    Science.gov (United States)

    Steele, Catriona M

    2018-06-01

    The ability to generate tongue pressures is widely considered to be critical for liquid bolus propulsion in swallowing. It has been proposed that the application of tongue pressure may also serve the function of collecting sensory information regarding bolus viscosity (resistance to flow). In this study, we explored the impact of age-related reductions in tongue strength on oral viscosity discrimination acuity. The experiment employed a triangle test discrimination protocol with an array of xanthan-gum thickened liquids in the mildly to moderately thick consistency range. A sample of 346 healthy volunteers was recruited, with age ranging from 12 to 86 (164 men, 182 women). On average, participants were able to detect a 0.29-fold increase in xanthan-gum concentration, corresponding to a 0.5-fold increase in viscosity at 50/s. Despite having significantly reduced tongue strength on maximum isometric tongue-palate pressure tasks, and regardless of sex, older participants in this study showed no reductions in viscosity discrimination acuity. In this article, the relationship between tongue strength and the ability to discriminate small differences in liquid viscosity during oral processing is explored. Given that tongue strength declines with age in healthy adults and is also reduced in individuals with dysphagia, it is interesting to determine whether reduced tongue strength might contribute to difficulties in evaluating liquid viscosity during the oral stage of swallowing. Using an array of mildly to moderately thick xanthan-gum thickened liquids, this experiment failed to find any evidence that reductions in tongue strength influence oral viscosity discrimination acuity. © 2017 Wiley Periodicals, Inc.

  13. A multi-channel stimulator and electrode array providing a rotating current whirlpool for electrical stimulation of wounds.

    Science.gov (United States)

    Petrofsky, J; Suh, H J; Fish, A; Hernandez, V; Abdo, A; Collins, K; Mendoza, E; Yang, T-N

    2008-01-01

    When electrical stimulation is used on wounds, the electrical current has difficulty penetrating areas where there is necrotic tissue. Further, for an irregularly shaped wound, current distribution is poor in some areas of the wound since conventional two-electrode delivery systems provide the greatest current in a line directly between the electrodes. A new stimulator and electrode system is described which uses three electrodes spaced around a wound to disperse current more evenly. The stimulator senses tissue impedance and then redirects current by altering its Thevenin's output impedance for each electrode; each of the three electrodes becomes the active one in sequence while the remaining are the sink electrodes. Eight subjects were examined to test the stimulator. Electrical stimulation was applied to the skin above the quadriceps muscle at currents of 15 mA in six subjects without wounds and in two subjects with wounds. The relationship between electrode position and current dispersion on the skin was examined with a two-electrode vs. a three-electrode system to set stimulation parameters for the computer. The results showed that the three-electrode system could (1) detect areas of the skin with high impedance; (2) compensate by altering the Thevenin's output impedance at each of the three electrodes to shift current to high impedance areas; (3) provide uniform current across the skin as assessed by skin current and blood flow measurements with a laser Doppler flow imager.

  14. Construction of Hierarchical CuO/Cu2O@NiCo2S4 Nanowire Arrays on Copper Foam for High Performance Supercapacitor Electrodes

    Science.gov (United States)

    Zhou, Luoxiao; He, Ying; Jia, Congpu; Pavlinek, Vladimir; Saha, Petr; Cheng, Qilin

    2017-01-01

    Hierarchical copper oxide @ ternary nickel cobalt sulfide (CuO/Cu2O@NiCo2S4) core-shell nanowire arrays on Cu foam have been successfully constructed by a facile two-step strategy. Vertically aligned CuO/Cu2O nanowire arrays are firstly grown on Cu foam by one-step thermal oxidation of Cu foam, followed by electrodeposition of NiCo2S4 nanosheets on the surface of CuO/Cu2O nanowires to form the CuO/Cu2O@NiCo2S4 core-shell nanostructures. Structural and morphological characterizations indicate that the average thickness of the NiCo2S4 nanosheets is ~20 nm and the diameter of CuO/Cu2O core is ~50 nm. Electrochemical properties of the hierarchical composites as integrated binder-free electrodes for supercapacitor were evaluated by various electrochemical methods. The hierarchical composite electrodes could achieve ultrahigh specific capacitance of 3.186 F cm−2 at 10 mA cm−2, good rate capability (82.06% capacitance retention at the current density from 2 to 50 mA cm−2) and excellent cycling stability, with capacitance retention of 96.73% after 2000 cycles at 10 mA cm−2. These results demonstrate the significance of optimized design and fabrication of electrode materials with more sufficient electrolyte-electrode interface, robust structural integrity and fast ion/electron transfer. PMID:28914819

  15. Construction of Hierarchical CuO/Cu₂O@NiCo₂S₄ Nanowire Arrays on Copper Foam for High Performance Supercapacitor Electrodes.

    Science.gov (United States)

    Zhou, Luoxiao; He, Ying; Jia, Congpu; Pavlinek, Vladimir; Saha, Petr; Cheng, Qilin

    2017-09-15

    Hierarchical copper oxide @ ternary nickel cobalt sulfide (CuO/Cu₂O@NiCo₂S₄) core-shell nanowire arrays on Cu foam have been successfully constructed by a facile two-step strategy. Vertically aligned CuO/Cu₂O nanowire arrays are firstly grown on Cu foam by one-step thermal oxidation of Cu foam, followed by electrodeposition of NiCo₂S₄ nanosheets on the surface of CuO/Cu₂O nanowires to form the CuO/Cu₂O@NiCo₂S₄ core-shell nanostructures. Structural and morphological characterizations indicate that the average thickness of the NiCo₂S₄ nanosheets is ~20 nm and the diameter of CuO/Cu₂O core is ~50 nm. Electrochemical properties of the hierarchical composites as integrated binder-free electrodes for supercapacitor were evaluated by various electrochemical methods. The hierarchical composite electrodes could achieve ultrahigh specific capacitance of 3.186 F cm -2 at 10 mA cm -2 , good rate capability (82.06% capacitance retention at the current density from 2 to 50 mA cm -2 ) and excellent cycling stability, with capacitance retention of 96.73% after 2000 cycles at 10 mA cm -2 . These results demonstrate the significance of optimized design and fabrication of electrode materials with more sufficient electrolyte-electrode interface, robust structural integrity and fast ion/electron transfer.

  16. Design, simulation and characterization of a MEMS inertia switch with flexible CNTs/Cu composite array layer between electrodes for prolonging contact time

    International Nuclear Information System (INIS)

    Wang, Yang; Yang, Zhuoqing; Xu, Qiu; Chen, Wenguo; Ding, Guifu; Zhao, Xiaolin

    2015-01-01

    This paper reports an inertia switch with a flexible carbon nanotubes/copper (CNTs/Cu) composite array layer between movable and fixed electrodes, which achieves a longer contact time compared to the traditional design using rigid-to-rigid impact between electrodes. The CNTs/Cu layer is fabricated using the composite electroplating method, and the whole device is completed by multi-layer metal electroplating based on the micro-electro-mechanical systems (MEMS) process. The dynamic responses of the designed inertia switch and the contact impact between a single CNT and a fixed electrode/another CNT have both been simulated by the ANSYS finite-element-method (FEM). It is shown that the contact time of the designed inertia switch is about 100 µs under the applied 80 g half-sine-shaped acceleration in the sensing direction. Finally, the fabricated MEMS inertia switch with the flexible CNTs/Cu composite array layer between electrodes has been evaluated by a dropping hammer system. The test contact time is about112 µs, which has a good agreement with the simulation and is much longer than that of the traditional design. (paper)

  17. Construction of Hierarchical CuO/Cu2O@NiCo2S4 Nanowire Arrays on Copper Foam for High Performance Supercapacitor Electrodes

    Directory of Open Access Journals (Sweden)

    Luoxiao Zhou

    2017-09-01

    Full Text Available Hierarchical copper oxide @ ternary nickel cobalt sulfide (CuO/Cu2O@NiCo2S4 core-shell nanowire arrays on Cu foam have been successfully constructed by a facile two-step strategy. Vertically aligned CuO/Cu2O nanowire arrays are firstly grown on Cu foam by one-step thermal oxidation of Cu foam, followed by electrodeposition of NiCo2S4 nanosheets on the surface of CuO/Cu2O nanowires to form the CuO/Cu2O@NiCo2S4 core-shell nanostructures. Structural and morphological characterizations indicate that the average thickness of the NiCo2S4 nanosheets is ~20 nm and the diameter of CuO/Cu2O core is ~50 nm. Electrochemical properties of the hierarchical composites as integrated binder-free electrodes for supercapacitor were evaluated by various electrochemical methods. The hierarchical composite electrodes could achieve ultrahigh specific capacitance of 3.186 F cm−2 at 10 mA cm−2, good rate capability (82.06% capacitance retention at the current density from 2 to 50 mA cm−2 and excellent cycling stability, with capacitance retention of 96.73% after 2000 cycles at 10 mA cm−2. These results demonstrate the significance of optimized design and fabrication of electrode materials with more sufficient electrolyte-electrode interface, robust structural integrity and fast ion/electron transfer.

  18. Interfacing 3D Engineered Neuronal Cultures to Micro-Electrode Arrays: An Innovative In Vitro Experimental Model

    Science.gov (United States)

    Tedesco, Mariateresa; Frega, Monica; Martinoia, Sergio; Pesce, Mattia; Massobrio, Paolo

    2015-01-01

    Currently, large-scale networks derived from dissociated neurons growing and developing in vitro on extracellular micro-transducer devices are the gold-standard experimental model to study basic neurophysiological mechanisms involved in the formation and maintenance of neuronal cell assemblies. However, in vitro studies have been limited to the recording of the electrophysiological activity generated by bi-dimensional (2D) neural networks. Nonetheless, given the intricate relationship between structure and dynamics, a significant improvement is necessary to investigate the formation and the developing dynamics of three-dimensional (3D) networks. In this work, a novel experimental platform in which 3D hippocampal or cortical networks are coupled to planar Micro-Electrode Arrays (MEAs) is presented. 3D networks are realized by seeding neurons in a scaffold constituted of glass microbeads (30-40 µm in diameter) on which neurons are able to grow and form complex interconnected 3D assemblies. In this way, it is possible to design engineered 3D networks made up of 5-8 layers with an expected final cell density. The increasing complexity in the morphological organization of the 3D assembly induces an enhancement of the electrophysiological patterns displayed by this type of networks. Compared with the standard 2D networks, where highly stereotyped bursting activity emerges, the 3D structure alters the bursting activity in terms of duration and frequency, as well as it allows observation of more random spiking activity. In this sense, the developed 3D model more closely resembles in vivo neural networks. PMID:26554533

  19. Decline of Low-Frequency Hearing in People With Ski-Slope Hearing Loss; Implications for Electrode Array Insertion.

    Science.gov (United States)

    Schuurbiers, Jasper; Dingemanse, Gertjan; Metselaar, Mick

    2017-12-01

    The decline of low-frequency hearing in people with ski-slope hearing loss varies and might depend on etiology. People with ski-sloping hearing loss might benefit from cochlear implantation with preservation of residual hearing. To reduce the risk of losing low-frequency hearing after implantation, the electrode-array can be inserted partially up to the desired frequency. That, however, obstructs electrical stimulation of lower frequencies. To decide between complete or partial insertion, knowledge regarding the natural decline of low-frequency hearing is helpful. Patients with at least two ski-slope audiograms over time were selected. We calculated progression at lower frequencies for 320 patients. Etiologies for hearing loss were retrieved from medical records. Progression of hearing loss was analyzed separately for patients with uni- and bilateral hearing losses. Relative progression of hearing loss was obtained by comparing progression to a reference group. Average progression of PTA was 1.73 dB/yr and was not significantly different in the bilateral and unilateral group. Etiologies that did not show significantly more progression compared with the reference group could be identified as single or short-lasting pathologic events, whereas long-lasting conditions had significant more progression of PTA. Patients with a ski-slope hearing loss that was caused by a single or short-lasting event have low progression rate and are viable for partial insertion to minimize the risk of damaging residual low-frequency hearing. In the absence of such an event, complete insertion should be considered because faster than normal deterioration of low-frequency hearing over time will probably limit the advantage of preservation of residual hearing.

  20. High-performance and renewable supercapacitors based on TiO2 nanotube array electrodes treated by an electrochemical doping approach

    International Nuclear Information System (INIS)

    Wu, Hui; Li, Dongdong; Zhu, Xufei; Yang, Chunyan; Liu, Dongfang; Chen, Xiaoyuan; Song, Ye; Lu, Linfeng

    2014-01-01

    Although one-dimensional anodic TiO 2 nanotube arrays have shown promise as supercapacitor electrode materials, their poor electronic conductivity embarrasses the practical applications. Here, we develop a simple electrochemical doping method to significantly improve the electronic conductivity and the electrochemical performances of TiO 2 nanotube electrodes. These TiO 2 nanotube electrodes treated by the electrochemical hydrogenation doping (TiO 2 -H) exhibit a very high average specific capacitance of 20.08 mF cm −2 at a current density of 0.05 mA cm −2 , ∼20 times more than the pristine TiO 2 nanotube electrodes. The improved electrochemical performances can be attributed to ultrahigh conductivity of TiO 2 -H due to the introduction of interstitial hydrogen ions and oxygen vacancies by the doping. The supercapacitor device assembled by the doped electrodes delivers a specific capacitance of 5.42 mF cm −2 and power density of 27.66 mW cm −2 , on average, at the current density of 0.05 mA cm −2 . The device also shows an outstanding rate capability with 60% specific capacitance retained when the current density increases from 0.05 to 4.00 mA cm −2 . More interestingly, the electrochemical performances of the supercapacitor after cycling can be recovered by the same doping process. This strategy boosts the performances of the supercapacitor, especially cycling stability

  1. Co(OH)2/RGO/NiO sandwich-structured nanotube arrays with special surface and synergistic effects as high-performance positive electrodes for asymmetric supercapacitors

    Science.gov (United States)

    Xu, Han; Zhang, Chi; Zhou, Wen; Li, Gao-Ren

    2015-10-01

    High power density, high energy density and excellent cycling stability are the main requirements for high-performance supercapacitors (SCs) that will be widely used for portable consumer electronics and hybrid electric vehicles. Here we investigate novel types of hybrid Co(OH)2/reduced graphene oxide (RGO)/NiO sandwich-structured nanotube arrays (SNTAs) as positive electrodes for asymmetric supercapacitors (ASCs). The synthesized Co(OH)2/RGO/NiO SNTAs exhibit a significantly improved specific capacity (~1470 F g-1 at 5 mV s-1) and excellent cycling stability with ~98% Csp retention after 10 000 cycles because of the fast transport and short diffusion paths for electroactive species, the high utilization rate of electrode materials, and special synergistic effects among Co(OH)2, RGO, and NiO. The high-performance ASCs are assembled using Co(OH)2/RGO/NiO SNTAs as positive electrodes and active carbon (AC) as negative electrodes, and they exhibit a high energy density (115 Wh kg-1), a high power density (27.5 kW kg-1) and an excellent cycling stability (less 5% Csp loss after 10 000 cycles). This study shows an important breakthrough in the design and fabrication of multi-walled hybrid nanotube arrays as positive electrodes for ASCs.High power density, high energy density and excellent cycling stability are the main requirements for high-performance supercapacitors (SCs) that will be widely used for portable consumer electronics and hybrid electric vehicles. Here we investigate novel types of hybrid Co(OH)2/reduced graphene oxide (RGO)/NiO sandwich-structured nanotube arrays (SNTAs) as positive electrodes for asymmetric supercapacitors (ASCs). The synthesized Co(OH)2/RGO/NiO SNTAs exhibit a significantly improved specific capacity (~1470 F g-1 at 5 mV s-1) and excellent cycling stability with ~98% Csp retention after 10 000 cycles because of the fast transport and short diffusion paths for electroactive species, the high utilization rate of electrode materials, and

  2. Application of an e-tongue to the analysis of monovarietal and blends of white wines.

    Science.gov (United States)

    Gutiérrez, Manuel; Llobera, Andreu; Ipatov, Andrey; Vila-Planas, Jordi; Mínguez, Santiago; Demming, Stefanie; Büttgenbach, Stephanus; Capdevila, Fina; Domingo, Carme; Jiménez-Jorquera, Cecilia

    2011-01-01

    This work presents a multiparametric system capable of characterizing and classifying white wines according to the grape variety and geographical origin. Besides, it quantifies specific parameters of interest for quality control in wine. The system, known as a hybrid electronic tongue, consists of an array of electrochemical microsensors-six ISFET based sensors, a conductivity sensor, a redox potential sensor and two amperometric electrodes, a gold microelectrode and a microelectrode for sensing electrochemical oxygen demand--and a miniaturized optofluidic system. The test sample set comprised eighteen Catalan monovarietal white wines from four different grape varieties, two Croatian monovarietal white wines and seven bi- and trivarietal mixtures prepared from the Catalan varieties. Different chemometric tools were used to characterize (i.e., Principal Component Analysis), classify (i.e., Soft Independent Modeling Class Analogy) and quantify (i.e., Partial-Least Squares) some parameters of interest. The results demonstrate the usefulness of the multisensor system for analysis of wine.

  3. Application of an E-Tongue to the Analysis of Monovarietal and Blends of White Wines

    Directory of Open Access Journals (Sweden)

    Carme Domingo

    2011-05-01

    Full Text Available This work presents a multiparametric system capable of characterizing and classifying white wines according to the grape variety and geographical origin. Besides, it quantifies specific parameters of interest for quality control in wine. The system, known as a hybrid electronic tongue, consists of an array of electrochemical microsensors—six ISFET based sensors, a conductivity sensor, a redox potential sensor and two amperometric electrodes, a gold microelectrode and a microelectrode for sensing electrochemical oxygen demand—and a miniaturized optofluidic system. The test sample set comprised eighteen Catalan monovarietal white wines from four different grape varieties, two Croatian monovarietal white wines and seven bi- and trivarietal mixtures prepared from the Catalan varieties. Different chemometric tools were used to characterize (i.e., Principal Component Analysis, classify (i.e., Soft Independent Modeling Class Analogy and quantify (i.e., Partial-Least Squares some parameters of interest. The results demonstrate the usefulness of the multisensor system for analysis of wine.

  4. Electronic Noses and Tongues in Wine Industry

    Directory of Open Access Journals (Sweden)

    Maria Luz Rodriguez-Mendez

    2016-10-01

    Full Text Available The quality of wines is usually evaluated by a sensory panel formed of trained experts or traditional chemical analysis. Over the last few decades, electronic noses and electronic tongues have been developed to determine the quality of foods and beverages. They consist of arrays of sensors with cross-sensitivity, combined with pattern recognition software, which provide a fingerprint of the samples that can be used to discriminate or classify the samples. This holistic approach is inspired by the method used in mammals to recognize food through their senses. They have been widely applied to the analysis of wines, including quality control, aging control or the detection of fraudulence, among others. In this paper, the current status of research and development in the field of electronic noses and tongues applied to the analysis of wines is reviewed. Their potential applications in the wine industry are described. The review ends with a final comment about expected future developments.

  5. A pH sensor based on the TiO{sub 2} nanotube array modified Ti electrode

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Rongrong; Xu Meizhu [Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, Department of Chemistry, Fuzhou University, 523 Gongye Road, Fuzhou 350002, Fujian (China); Wang Jian, E-mail: jwang@fzu.edu.c [Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, Department of Chemistry, Fuzhou University, 523 Gongye Road, Fuzhou 350002, Fujian (China); Chen Guonan, E-mail: guonanchen@126.co [Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, Department of Chemistry, Fuzhou University, 523 Gongye Road, Fuzhou 350002, Fujian (China)

    2010-08-01

    In this paper, a novel solid state pH sensor was fabricated by anodization of titanium substrate electrode. The relationship between pH sensitivity and hydrophilicity or surface morphology of TiO{sub 2} film was investigated. Amorphous TiO{sub 2} nanotube has better pH response than anatase TiO{sub 2} nanotube. After being irradiated by ultraviolet light (UV), the potential response of the electrode modified by amorphous TiO{sub 2} nanotube was close to Nernst equation (59 mV/pH). SEM, XRD, and XPS were used to characterize electrodes. Possible mechanism was discussed by analyzing surface hydroxyl groups, crystal structure and hydrophilicity of the electrodes. The electrode has been used to detect some kinds of soft drinks and shows good response.

  6. AMDO TIBETAN TONGUE TWISTERS

    Directory of Open Access Journals (Sweden)

    Blo rtan rdo rje

    2009-06-01

    Full Text Available Tibetan tongue twisters are a distinctive and significant part of Tibetan oral folk literature. They are made up of words and phrases related to what people see and experience in daily life. These words are strung together and are difficult to articulate rapidly and fluently, often because of a succession of questions and/ or similar consonantal sounds. This article sheds light on this poorly studied, vanishing, aspect of Tibetan tradition by focusing on tongue twisters that were once popular in Pha bzhi (Hayu 哈 玉 , a subdivision of Skya rgya (Jiajia 贾 加 Administrative Village, Skya rgya Township, Gcan tsha (Jianzha 尖扎 County, Rma lho (Huangnan 黄南 Tibetan Autonomous Prefecture, Mtsho sngon (Qinghai 青海 Province, PR China.

  7. "Hidden" tongue jewellery.

    LENUS (Irish Health Repository)

    McNamara, C M

    2001-06-01

    Tongue piercing has many associated risks. This is a case report of a patient who, to avoid parental disapproval, hid the dorsal aspect of a lingual stud device. Subsequently, the dorsum repaired. The device could no longer be removed manually and warranted surgical removal. Despite being in situ for over two years, no further complications arose, but all efforts to obtain patient agreement for removal of the device failed.

  8. Bias-polarity-dependent UV/visible transferable electroluminescence from ZnO nanorod array LED with graphene oxide electrode supporting layer

    Science.gov (United States)

    Liu, Weizhen; Wang, Wei; Xu, Haiyang; Li, Xinghua; Yang, Liu; Ma, Jiangang; Liu, Yichun

    2015-09-01

    A simple top electrode preparation process, employing continuous graphene oxide films as electrode supporting layers, was adopted to fabricate a ZnO nanorod array/p-GaN heterojunction LED. The achieved LED demonstrated different electroluminescence behaviors under forward and reverse biases: a yellow-red emission band was observed under forward bias, whereas a blue-UV emission peak was obtained under reverse bias. Electroluminescence spectra under different currents and temperatures, as well as heterojunction energy-band alignments, reveal that the yellow-red emission under forward bias originates from recombinations related to heterointerface defects, whereas the blue-UV electroluminescence under reverse bias is ascribed to transitions from near-band-edge and Mg-acceptor levels in p-GaN.

  9. Electrooxidation of C{sub 1} to C{sub 3} alcohols with Pt and Pt-Ru sputter deposited interdigitated array electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choong-Gon [Department of Chemical Engineering, Faculty of Engineering, Hanbat National University, San 16-1, Dukmyeong-dong, Yuseong-gu, Daejeon 305-719 (Korea, Republic of)], E-mail: leecg@hanbat.ac.kr; Ojima, Hiroyuki [Department of Applied Chemistry, Graduate School of Engineering, Tohoku University, Aramaki-Aoba 07, Aoba-ku, Sendai 980-8579 (Japan); Umeda, Minoru [Department of Materials Science and Technology, Faculty of Engineering, Nagaoka University of Technology, Kamitomioka 1603-1, Nagaoka, Niigata 940-2188 (Japan)], E-mail: mumeda@vos.nagaokaut.ac.jp

    2008-02-25

    The electrooxidation of methanol, ethanol, and 2-propanol was investigated with interdigitated array electrodes (IDAEs). The IDAE oxidizes alcohol at the generator and reduces the reaction intermediates produced by the oxidation process at the collector. Thus, the reaction intermediates can be estimated with the IDAE. The IDAE in the present work was made of sputter deposited Pt and Pt-Ru. The use of Ru free and added electrodes provides information on the effect of Ru addition on the alcohol oxidation. Cyclic voltammetric analyses revealed that Ru addition enhances the oxidation currents and reduces the E{sub onset} of the alcohols. The detectable reaction intermediate at the methanol and ethanol oxidation was proton, while the intermediate species was acetone in 2-propnaol oxidation.

  10. Scrotal tongue and geographic tongue: polygenic and associated traits.

    Science.gov (United States)

    Eidelman, E; Chosack, A; Cohen, T

    1976-11-01

    The familial nature of scrotal and geographic tongue was investigated in parents and siblings of 156 probands having these conditions. The prevalence in parents and siblings was significantly higher than that in the control populations. The prevalence in sibilings from families in which at least one parent was also affected was significantly higher than that in siblings from families in which neither parent was affected. The prevalence of scrotal tongue alone in siblins was similar irrespective of the condition in the proband. The prevalence of geographic tongue alone was highest in siblins of probands having only geographic tongue. A polygenic mode of inheritance with some genes common to both conditions is suggested.

  11. Artificial tongue based on metal-biomolecule coordination polymer nanoparticles.

    Science.gov (United States)

    Pu, Fang; Ran, Xiang; Ren, Jinsong; Qu, Xiaogang

    2016-02-25

    We construct an array-based recognition system (the so-called artificial tongue) through the self-assembly of nucleotides, dyes and lanthanide ions. Metal ions are selected as model analytes for verifying its discrimination ability. The work provides valuable insights into the application and development of biomolecule-based materials.

  12. Tongue metastasis mimicking an abscess.

    Science.gov (United States)

    Mavili, Ertuğrul; Oztürk, Mustafa; Yücel, Tuba; Yüce, Imdat; Cağli, Sedat

    2010-03-01

    Primary tumors metastasizing to the oral cavity are extremely rare. Lung is one of the most common primary sources of metastases to the tongue. Although the incidence of lung cancer is increasing, tongue metastasis as the initial presentation of the tumor remains uncommon. Due to the rarity of tongue metastasis, little is known about its imaging findings. Herein we report the magnetic resonance imaging and clinical findings of a lingual metastasis, mimicking an abscess, from a primary lung cancer.

  13. Robust electrodes based on coaxial TiC/C-MnO2 core/shell nanofiber arrays with excellent cycling stability for high-performance supercapacitors.

    Science.gov (United States)

    Zhang, Xuming; Peng, Xiang; Li, Wan; Li, Limin; Gao, Biao; Wu, Guosong; Huo, Kaifu; Chu, Paul K

    2015-04-17

    A coaxial electrode structure composed of manganese oxide-decorated TiC/C core/shell nanofiber arrays is produced hydrothermally in a KMnO4 solution. The pristine TiC/C core/shell structure prepared on the Ti alloy substrate provides the self-sacrificing carbon shell and highly conductive TiC core, thus greatly simplifying the fabrication process without requiring an additional reduction source and conductive additive. The as-prepared electrode exhibits a high specific capacitance of 645 F g(-1) at a discharging current density of 1 A g(-1) attributable to the highly conductive TiC/C and amorphous MnO2 shell with fast ion diffusion. In the charging/discharging cycling test, the as-prepared electrode shows high stability and 99% capacity retention after 5000 cycles. Although the thermal treatment conducted on the as-prepared electrode decreases the initial capacitance, the electrode undergoes capacitance recovery through structural transformation from the crystalline cluster to layered birnessite type MnO2 nanosheets as a result of dissolution and further electrodeposition in the cycling. 96.5% of the initial capacitance is retained after 1000 cycles at high charging/discharging current density of 25 A g(-1). This study demonstrates a novel scaffold to construct MnO2 based SCs with high specific capacitance as well as excellent mechanical and cycling stability boding well for future design of high-performance MnO2-based SCs. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Honey adulteration detection: voltammetric e-tongue versus official methods for physicochemical parameter determination.

    Science.gov (United States)

    Oroian, Mircea; Paduret, Sergiu; Ropciuc, Sorina

    2018-02-10

    The aim of this study was to evaluate the usefulness of a voltammetric e-tongue (three electrodes: reference electrode (Ag/AgCl), counter electrode (glassy carbon electrode rod) and working electrode (Au, Ag, Pt and glass electrode)) for honey adulteration detection. For this purpose, 55 samples of authentic honey (acacia, honeydew, sunflower, Tilia and polyfloral) and 150 adulterated ones were analyzed. The adulteration was made using fructose, glucose, inverted sugar, hydrolyzed inulin syrup and malt wort at different percentages: 5%, 10%, 20%, 30%, 40% and 50%, respectively. The e-tongue has been compared with the physicochemical parameters (pH, free acidity, electrical conductivity (EC) and CIEL*a*b* parameters (L*, a* and b*)) in order to achieve a suitable method for the classification of authentic and adulterated honeys. The e-tongue and physicochemical parameters reached a 97.50% correct classification of the authentic and adulterated honeys. In the case of the adulterated honey samples, the e-tongue achieved 83.33% correct classifications whereas the physicochemical parameters only achieved 73.33%. The e-tongue is a fast, easy and accurate method for honey adulteration detection which can be used in situ by beekeepers and provide useful information on EC and free acidity. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  15. Localised electrochemical impedance measurements of a polymer electrolyte fuel cell using a reference electrode array to give cathode-specific measurements and examine membrane hydration dynamics

    Science.gov (United States)

    Engebretsen, Erik; Hinds, Gareth; Meyer, Quentin; Mason, Tom; Brightman, Edward; Castanheira, Luis; Shearing, Paul R.; Brett, Daniel J. L.

    2018-04-01

    Advances in bespoke diagnostic techniques for polymer electrolyte fuel cells continue to provide unique insight into the internal operation of these devices and lead to improved performance and durability. Localised measurements of current density have proven to be extremely useful in designing better fuel cells and identifying optimal operating strategies, with electrochemical impedance spectroscopy (EIS) now routinely used to deconvolute the various losses in fuel cells. Combining the two techniques provides another dimension of understanding, but until now each localised EIS has been based on 2-electrode measurements, composed of both the anode and cathode responses. This work shows that a reference electrode array can be used to give individual electrode-specific EIS responses, in this case the cathode is focused on to demonstrate the approach. In addition, membrane hydration dynamics are studied under current load steps from open circuit voltage. A three-stage process is identified associated with an initial rapid reduction in membrane resistance after 10 s of applying a current step, followed by a slower ramp to approximately steady state, which was achieved after ∼250 s. These results support previously published work that has looked at membrane swelling dynamics and reveal that membrane hydration/membrane resistance is highly heterogeneous.

  16. Improved electrochemical performances of binder-free CoMoO4 nanoplate arrays@Ni foam electrode using redox additive electrolyte

    Science.gov (United States)

    Veerasubramani, Ganesh Kumar; Krishnamoorthy, Karthikeyan; Kim, Sang Jae

    2016-02-01

    Herein, we are successfully prepared cobalt molybdate (CoMoO4) grown on nickel foam as a binder free electrode by hydrothermal approach for supercapacitors and improved their electrochemical performances using potassium ferricyanide (K3Fe(CN)6) as redox additive. The formation of CoMoO4 on Ni foam with high crystallinity is confirmed using XRD, Raman, and XPS measurements. The nanoplate arrays (NPAs) of CoMoO4 are uniformly grown on Ni foam which is confirmed by FE-SEM analysis. The prepared binder-free CoMoO4 NPAs achieved maximum areal capacity of 227 μAh cm-2 with KOH electrolyte at 2.5 mA cm-2. This achieved areal capacity is further improved about three times using the addition of K3Fe(CN)6 as redox additive. The increased electrochemical performances of CoMoO4 NPAs on Ni foam electrode via redox additive are discussed in detail and the mechanism has been explored. Moreover, the assembled CoMoO4 NPAs on Ni foam//activated carbon asymmetric supercapacitor device with an extended operating voltage window of 1.5 V exhibits an excellent performances such as high energy density and cyclic stability. The overall performances of binder-free CoMoO4 NPAs on Ni foam with redox additives suggesting their potential use as positive electrode material for high performance supercapacitors.

  17. Literacy and the Mother Tongue

    Science.gov (United States)

    Literacy Work, 1974

    1974-01-01

    Reviewing the situation of literacy in the mother tongue, the article reports on projects in: (1) Africa--Mali and Nigeria, (2) the Amazonian jungle of Peru in Latin America, and (3) Papua, New Guinea. Psychological, sociological, and educational advantages of the mother tongue are discussed. (MW)

  18. Did mosasaurs have forked tongues?

    NARCIS (Netherlands)

    Schulp, Anne S.; Mulder, E. W. A.; Schwenk, K.

    Ever since the first mosasaur restorations were published, these extinct marine reptiles have been pictured with either notched, forked or undivided tongues. Here, we present an overview of existing iconography, a review of the previous literature, and we discuss how best to reconstruct tongue form

  19. Hummingbird tongues are elastic micropumps

    Science.gov (United States)

    Rico-Guevara, Alejandro; Fan, Tai-Hsi; Rubega, Margaret A.

    2015-01-01

    Pumping is a vital natural process, imitated by humans for thousands of years. We demonstrate that a hitherto undocumented mechanism of fluid transport pumps nectar onto the hummingbird tongue. Using high-speed cameras, we filmed the tongue–fluid interaction in 18 hummingbird species, from seven of the nine main hummingbird clades. During the offloading of the nectar inside the bill, hummingbirds compress their tongues upon extrusion; the compressed tongue remains flattened until it contacts the nectar. After contact with the nectar surface, the tongue reshapes filling entirely with nectar; we did not observe the formation of menisci required for the operation of capillarity during this process. We show that the tongue works as an elastic micropump; fluid at the tip is driven into the tongue's grooves by forces resulting from re-expansion of a collapsed section. This work falsifies the long-standing idea that capillarity is an important force filling hummingbird tongue grooves during nectar feeding. The expansive filling mechanism we report in this paper recruits elastic recovery properties of the groove walls to load nectar into the tongue an order of magnitude faster than capillarity could. Such fast filling allows hummingbirds to extract nectar at higher rates than predicted by capillarity-based foraging models, in agreement with their fast licking rates. PMID:26290074

  20. Fabrication and characterization of ZnO nanowires array electrodes with high photocurrent densities: Effects of the seed layer calcination time

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yi-Jing; Liu, Ching-Fang; Hu, Chi-Chang, E-mail: cchu@che.nthu.edu.tw; Kuo, Jen-Hou; Boddula, Rajender

    2017-03-01

    In this work, we demonstrate that vertically grown ZnO nanowire (NW) arrays of the wurzite phase were successfully fabricated on fluorine doped tin oxide (FTO) substrates via a hydrothermal method. The coating of a seed layer onto the FTO substrates was found to favor the growth of a uniform ZnO NWs array which shows saturation in the photocurrent density with a relatively low potential bias. Furthermore, prolonging the calcination time of the seed layer makes the ZnO NWs behave the better charge separation and improve the photo-electrochemical performance. Under the irradiation at a 75 mW cm{sup −2} from a simulated sunlight source, the ZnO NWs array electrode prepared from the seed layer with calcination at 350 °C for 5 h shows a saturated photocurrent density of 514 μA cm{sup −2} and a maximum half-cell solar-to-hydrogen (HC-STH) efficiency of 0.26% was obtained at 0.6 V versus reversible hydrogen electrode (RHE) in neutral electrolyte. - Highlights: • The seed layer annealing time strongly influences the textural and photo-activity of ZnO NWs. • The average diameter and density of ZnO NWs were controlled to 47–70 nm and 46–70 NWs μm{sup −2}, respectively. • ZnO NWs show promising application potential in solar-electrocatalytic water splitting under potential bias. • The ZnO NWs with SL annealing time = 5 h achieve the highest HC-STH efficiency of 0.26% at 0.6 V.

  1. Facile synthesis of ultrathin manganese dioxide nanosheets arrays on nickel foam as advanced binder-free supercapacitor electrodes

    KAUST Repository

    Huang, Ming; Zhao, Xiao Li; Li, Fei; Zhang, Li Li; Zhang, Yu Xin

    2015-01-01

    -free electrode exhibits a high specific capacitance (595.2 F g-1 at a current density of 0.5 A g-1), good rate capability (64.1% retention), and excellent cycling stability (89% capacitance retention after 3000 cycles). Moreover, an asymmetric supercapacitor

  2. Galvanic Couple Current and Potential Distribution between a Mg Electrode and 2024-T351 under Droplets Analyzed by Microelectrode Arrays

    Science.gov (United States)

    2015-11-04

    system as a function of coating parameters, physical conditions, as well as environment. Experimental Materials.— 99.9% magnesium rod (8.0 mm diam.), 500...μm di- ameter 99.9% magnesium wire, 1.6 mm thick AA2024-T351 sheet, Table I. Composition of AA2024-T351 used as a bare electrode in these...selected because they enable electrochemical impedance spectroscopy ( EIS ) measurements along with traditional electrochemical measure- ments. Saturated

  3. Understanding the effect of morphology on the photocatalytic activity of TiO2 nanotube array electrodes

    International Nuclear Information System (INIS)

    Adán, C.; Marugán, J.; Sánchez, E.; Pablos, C.; Grieken, R. van

    2016-01-01

    A comprehensive report on the correlation between the morphology and the photocatalytic (PC) and photoelectrocatalytic (PEC) activity of TiO 2 nanotubes (NTs) electrodes is presented. New insights are provided to support the effect of the anodization conditions on the photon-to-current efficiency of the electrodes based on the dimensional characteristics of the TiO 2 -NTs. Electrodes with promising properties based on the characterization data were scaled-up to test their activity on the PC and PEC oxidation of methanol. Results indicate that the length of the nanotubes significantly influences the photodegradation efficiency. The enhancement achieved in both PC and PEC processes with longer nanotubes can be explained by the higher surface area in contact with the electrolyte and the increase in the light absorption as the TiO 2 layer becomes thicker. However, as the length of the nanotubes increases, a reduction in the enhancement achieved by the application of a potential bias is observed. Kinetic constants of both reactions (PC and PEC) tend to get closer and the charge separation effect diminishes. In relative terms, the effect of the electric potential is more pronounced for electrodes with the shorter NTs. The reason is that once the TiO 2 layer is thick enough to absorb the available radiation, a further increase in the NTs length increases the resistance of the electrons to reach the back contact and the diffusional restrictions to the mass transport of the reactants/products along the tubes. Consequently, the existence of a compromise between reactivity and transport properties lead to the existence of an optimal NTs length.

  4. A voltammetric electronic tongue as tool for water quality monitoring in wastewater treatment plants.

    Science.gov (United States)

    Campos, Inmaculada; Alcañiz, Miguel; Aguado, Daniel; Barat, Ramón; Ferrer, José; Gil, Luis; Marrakchi, Mouna; Martínez-Mañez, Ramón; Soto, Juan; Vivancos, José-Luis

    2012-05-15

    The use of a voltammetric electronic tongue as tool for the prediction of concentration levels of certain water quality parameters from influent and effluent wastewater from a Submerged Anaerobic Membrane Bioreactor pilot plant applied to domestic wastewater treatment is proposed here. The electronic tongue consists of a set of noble (Au, Pt, Rh, Ir, and Ag) and non-noble (Ni, Co and Cu) electrodes that were housed inside a stainless steel cylinder which was used as the body of the electronic tongue system. As a previous step an electrochemical study of the response of the ions sulphate, orthophosphate, acetate, bicarbonate and ammonium was carried out in water using the electrodes contained in the electronic tongue. The second part of the work was devoted to the application of the electronic tongue to the characterization of the influent and effluent waters from the wastewater treatment plant. Partial Least Squares analysis was used to obtain a correlation between the data from the tongue and the pollution parameters measured in the laboratory such as soluble chemical oxygen demand (CODs), soluble biological oxygen demand (BODs), ammonia (NH(4)-N), orthophosphate (PO(4)-P), Sulphate (SO(4)-S), acetic acid (HAC) and alkalinity (Alk). A total of 28 and 11 samples were used in the training and the validation steps, respectively, for both influent and effluent water samples. The electronic tongue showed relatively good predictive power for the determination of BOD, COD, NH(4)-N, PO(4)-P, SO(4)-S, and Alk. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. The neck-tongue syndrome.

    Science.gov (United States)

    Orrell, R W; Marsden, C D

    1994-01-01

    The neck-tongue syndrome, consisting of pain in the neck and altered sensation in the ipsilateral half of the tongue aggravated by neck movement, has been attributed to damage to lingual afferent fibres travelling in the hypoglossal nerve to the C2 spinal roots. The lingual afferents in the hypoglossal nerve are thought to be proprioceptive. Two further cases of the neck-tongue syndrome are described, the spectrum of its clinical manifestations is explored, and the phenomenon of lingual pseudoathetosis is illustrated as a result of the presumed lingual deafferentation. Images PMID:8158185

  6. Label-Free Impedance Sensing of Aflatoxin B1 with Polyaniline Nanofibers/Au Nanoparticle Electrode Array

    Directory of Open Access Journals (Sweden)

    Ajay Kumar Yagati

    2018-04-01

    Full Text Available Aflatoxin B1 (AFB1 is produced by the Aspergillus flavus and Aspergillus parasiticus group of fungi which is most hepatotoxic and hepatocarcinogenic and occurs as a contaminant in a variety of foods. AFB1 is mutagenic, teratogenic, and causes immunosuppression in animals and is mostly found in peanuts, corn, and food grains. Therefore, novel methodologies of sensitive and expedient strategy are often required to detect mycotoxins at the lowest level. Herein, we report an electrochemical impedance sensor that selectively detects AFB1 at the lowest level by utilizing polyaniline nanofibers (PANI coated with gold (Au nanoparticles composite based indium tin oxide (ITO disk electrodes. The Au-PANI nanocomposites were characterized by scanning electron microscopy (SEM, X-ray diffraction (XRD spectroscopy, and electrochemical impedance spectroscopy (EIS. The composite electrode exhibited a 14-fold decrement in |Z|1 Hz in comparison with the bare electrode. The Au-PANI acted as an effective sensing platform having high surface area, electrochemical conductivity, and biocompatibility which enabled greater loading deposits of capture antibodies. As a result, the presence of AFB1 was screened with high sensitivity and stability by monitoring the changes in impedance magnitude (|Z| in the presence of a standard iron probe which was target specific and proportional to logarithmic AFB1 concentrations (CAFB1. The sensor exhibits a linear range 0.1 to 100 ng/mL with a detection limit (3σ of 0.05 ng/mL and possesses good reproducibility and high selectivity against another fungal mycotoxin, Ochratoxin A (OTA. With regard to the practicability, the proposed sensor was successfully applied to spiked corn samples and proved excellent potential for AFB1 detection and development of point-of-care (POC disease sensing applications.

  7. A Wireless and Batteryless Microsystem with Implantable Grid Electrode/3-Dimensional Probe Array for ECoG and Extracellular Neural Recording in Rats

    Directory of Open Access Journals (Sweden)

    Chih-Wei Chang

    2013-04-01

    Full Text Available This paper presents the design and implementation of an integrated wireless microsystem platform that provides the possibility to support versatile implantable neural sensing devices in free laboratory rats. Inductive coupled coils with low dropout regulator design allows true long-term recording without limitation of battery capacity. A 16-channel analog front end chip located on the headstage is designed for high channel account neural signal conditioning with low current consumption and noise. Two types of implantable electrodes including grid electrode and 3D probe array are also presented for brain surface recording and 3D biopotential acquisition in the implanted target volume of tissue. The overall system consumes less than 20 mA with small form factor, 3.9 × 3.9 cm2 mainboard and 1.8 × 3.4 cm2 headstage, is packaged into a backpack for rats. Practical in vivo recordings including auditory response, brain resection tissue and PZT-induced seizures recording demonstrate the correct function of the proposed microsystem. Presented achievements addressed the aforementioned properties by combining MEMS neural sensors, low-power circuit designs and commercial chips into system-level integration.

  8. Nickel Nanowire@Porous NiCo{sub 2}O{sub 4} Nanorods Arrays Grown on Nickel Foam as Efficient Pseudocapacitor Electrode

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Houzhao; Li, Lang; Zhang, Jun; Liu, Xiang; Wang, Hanbin; Wang, Hao, E-mail: nanoguy@126.com [Faculty of Physics and Electronic Science, Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials, Hubei Key Laboratory of Ferro & Piezoelectric Materials and Devices, Hubei University, Wuhan (China)

    2017-12-13

    A three dimensional hierarchical nanostructure composed of nickel nanowires and porous NiCo{sub 2}O{sub 4} nanorods arrays on the surface of nickel foam is successfully fabricated by a facile route. In this structure, the nickel nanowires are used as core materials to support high-pseudocapacitance NiCo{sub 2}O{sub 4} nanorods and construct the well-defined NiCo{sub 2}O{sub 4} nanorods shell/nickel nanowires core hierarchical structure on nickel foam. Benefiting from the participation of nickel nanowires, the nickel nanowire@NiCo{sub 2}O{sub 4}/Ni foam electrode shows a high areal specific capacitance (7.4 F cm{sup −2} at 5 mA cm{sup −2}), excellent rate capability (88.04% retained at 100 mA cm{sup −2}), and good cycling stability (74.08% retained after 1,500 cycles). The superior electrochemical properties made it promising as electrode for supercapacitors.

  9. Nonenzymatic determination of glucose at near neutral pH values based on the use of nafion and platinum black coated microneedle electrode array.

    Science.gov (United States)

    Chinnadayyala, Somasekhar R; Park, Ilhwan; Cho, Sungbo

    2018-04-07

    The authors report on a microneedle-based amperometric nonenzymatic glucose sensor for painless and continuous monitoring of glucose. It consists of 3 × 5 sharp stainless steel microneedles micromachined from a stainless steel substrate. The microneedles are 600 and 100 μm in height and width, respectively. Nafion and platinum black were sequentially coated onto the tip of gold-coated microneedles and used for nonenzymatic (direct) sensing of glucose. Attractive features of the modified microneedle electrode include (a) a low working potential (+0.12 V vs. Ag/AgCl), (b) a linear response in the physiologically relevant range (1-40 mM), (c) a sensitivity as high as 175 μA mM -1  cm -2 , (d) a 23 μM detection limit, and (e) a response time of 2 s. The sensor also exhibits good reproducibility and stability. The sensor is selective for glucose even in the presence of 10-fold higher concentrations of ascorbic acid, lactic acid, dopamine, uric acid, and acetaminophen. Graphical abstract Schematic representation of the fabrication sequence for a nonenzymatic electrochemical glucose sensor using Nafion and platinum black coated microneedle electrode array. The sensor is based on measuring the faradaic current at +0.12 V vs. Ag/AgCl by the direct electrochemical oxidation of glucose to gluconic acid on the surface of a Pt black sensing layer.

  10. Linezolid induced black hairy tongue

    OpenAIRE

    Govindan Balaji; B Maharani; Velappan Ravichandran; Thiyagarajan Parthasarathi

    2014-01-01

    Black hairy tongue (BHT) also called as lingua villosa nigra, is a self limiting benign condition characterized by hypertrophy and elongation of filiform papillae of tongue with brown or black discoloration. Smoking, poor oral hygiene, xerostomia, using peroxide containing mouth washes, substance abuse and drugs (steroids, methyldopa, olanzapine, etc) are the predisposing factors. However its occurrence in relation to linezolid ingestion among south Indians has not been reported in PubMed dat...

  11. Arnold Tongues in Cell Dynamics

    Science.gov (United States)

    Jensen, Mogens

    In a recent work with Leo Kadanoff we studied the synchronization between an internal and an external frequency. One obtains a highly structured diagram with details that in essence are related to the difference between rational and irrational number. The synchronized regions appear as Arnold tongues that widen as the coupling between the frequencies increases. Such tongues have been observed in many physical systems, like in the Libchaber convective cell in the basement of the University of Chicago. In biological systems, where oscillators appear in in a broad variety, very little research on Arnold tongues has been performed. We discuss single cell oscillating dynamics triggered by an external cytokine signal. When this signal is overlaid by an oscillating variation, the two oscillators might couple leading to Arnold tongue diagram. When the tongues overlap, the cell dynamics can shift between the tongues eventually leading to a chaotic response. We quantify such switching in single cell experiments and in model systems based on Gillespie simulations. Kadanoff session.

  12. Spinel FeCo2S4 nanoflower arrays grown on Ni foam as novel binder-free electrodes for long-cycle-life supercapacitors

    Science.gov (United States)

    Deng, Cuifen; Yang, Lishan; Yang, Chunming; Shen, Ping; Zhao, Liping; Wang, Zhiyu; Wang, Chunhui; Li, Junhua; Qian, Dong

    2018-01-01

    Spinel FeCo2S4 nanoflower arrays grown on Ni foam (FeCo2S4@Ni) have been successfully fabricated via a facile hydrothermal sulfurization of the corresponding FeCo2O4 precursor. The results of X-ray diffraction and X-ray photoelectron spectroscopy characterizations affirm that partial Co2+/Co3+ ions in Co3S4 have been substituted by Fe2+/Fe3+ ions to form FeCo2S4. The obtained FeCo2S4@Ni exhibits an ultrahigh specific capacitance (1644.07 mF cm-2 at 50 mA cm-2) and a supreme cycling stability (∼100% after 10,000 cycles at 50 mA cm-2) as binder-free electrodes for supercapacitors. The cycling stability of the fabricated product is the highest among the documented ternary metallic sulfides so far. The excellent supercapacitive performance of FeCo2S4@Ni emanates from the unique architectures of Fe2Co2S4 nanoflower arrays constituted by ultrathin nanoflakes, three-dimensional porous and conductive Ni foam, and solid skeleton of Ni foam for robust connections to the Fe2Co2S4.

  13. Site of cochlear stimulation and its effect on electrically evoked compound action potentials using the MED-EL standard electrode array

    Directory of Open Access Journals (Sweden)

    Helbig Silke

    2009-12-01

    Full Text Available Abstract Background The standard electrode array for the MED-EL MAESTRO cochlear implant system is 31 mm in length which allows an insertion angle of approximately 720°. When fully inserted, this long electrode array is capable of stimulating the most apical region of the cochlea. No investigation has explored Electrically Evoked Compound Action Potential (ECAP recordings in this region with a large number of subjects using a commercially available cochlear implant system. The aim of this study is to determine if certain properties of ECAP recordings vary, depending on the stimulation site in the cochlea. Methods Recordings of auditory nerve responses were conducted in 67 subjects to demonstrate the feasibility of ECAP recordings using the Auditory Nerve Response Telemetry (ART™ feature of the MED-EL MAESTRO system software. These recordings were then analyzed based on the site of cochlear stimulation defined as basal, middle and apical to determine if the amplitude, threshold and slope of the amplitude growth function and the refractory time differs depending on the region of stimulation. Results Findings show significant differences in the ECAP recordings depending on the stimulation site. Comparing the apical with the basal region, on average higher amplitudes, lower thresholds and steeper slopes of the amplitude growth function have been observed. The refractory time shows an overall dependence on cochlear region; however post-hoc tests showed no significant effect between individual regions. Conclusions Obtaining ECAP recordings is also possible in the most apical region of the cochlea. However, differences can be observed depending on the region of the cochlea stimulated. Specifically, significant higher ECAP amplitude, lower thresholds and steeper amplitude growth function slopes have been observed in the apical region. These differences could be explained by the location of the stimulating electrode with respect to the neural tissue

  14. Monitoring of quality and storage time of unsealed pasteurized milk by voltammetric electronic tongue

    International Nuclear Information System (INIS)

    Wei, Zhenbo; Wang, Jun; Zhang, Xi

    2013-01-01

    A voltammetric electronic tongue (VE-tongue) was self-developed and applied to monitor the quality and storage time of unsealed pasteurized milk. The VE-tongue comprised four working electrodes: gold, silver, platinum, and palladium electrode. Two potential waveforms: Multi-frequency rectangle pulse voltammetry (MRPV) and multi-frequency staircase pulse voltammetry (MSPV) were applied to working electrodes in the study, and both of MRPV and MSPV consisted of three frequency segments: 1 Hz, 10 Hz, and 100 Hz. The total areas under the corresponding curves obtained by VE-tongue in the three frequencies were applied as characteristic data, which were evaluated by the principal component analysis (PCA) and cluster analysis (CA). The results of PCA and CA indicate that the milk samples of different storage time could be successfully classified by the VE-tongue based on MRPV and MSPV, respectively. Combining the areas obtained by the VE-tongue based on MRPV and MSPV, the classification results of PCA and CA were improved evidently. The total bacterial count, acidity and viscosity of the milk samples were also measured during the storage, and those physicochemical characteristics showed regular configuration in PCA and CA plots. Furthermore, the total bacterial count and viscosity properties were predicted by partial least squares regression (PLSR) and least squares-support vector machines (LS-SVM), and the combination of the areas obtained by the VE-tongue based on the MRPV and MSPV were applied as the input data of PLSR and LS-SVM. Both the prediction techniques performed well in predicting viscosity and total bacterial count, and the prediction results of LS-SVM were better than that of PLSR. Those results demonstrate that the VE-tongue could be applied to monitor the quality storage time of unsealed pasteurized milk

  15. Hybrid electronic tongue based on optical and electrochemical microsensors for quality control of wine.

    Science.gov (United States)

    Gutiérrez, Manuel; Llobera, Andreu; Vila-Planas, Jordi; Capdevila, Fina; Demming, Stefanie; Büttgenbach, Stephanus; Mínguez, Santiago; Jiménez-Jorquera, Cecilia

    2010-07-01

    A multiparametric system able to classify red and white wines according to the grape varieties and for analysing some specific parameters is presented. The system, known as hybrid electronic tongue, consists of an array of electrochemical microsensors and a colorimetric optofluidic system. The array of electrochemical sensors is composed of six ISFETs based sensors, a conductivity sensor, a redox potential sensor and two amperometric electrodes, an Au microelectrode and a microelectrode for sensing electrochemical oxygen demand. The optofluidic system is entirely fabricated in polymer technology and comprises a hollow structure, air mirrors, microlenses and self-alignment structures. The data obtained from these sensors has been treated with multivariate advanced tools; Principal Component Analysis (PCA), for the patterning recognition and classification of wine samples, and Partial-Least Squares (PLS) regression, for quantification of several chemical and optical parameters of interest in wine quality. The results have demonstrated the utility of this system for distinguishing the samples according to the grape variety and year vintage and for quantifying several sample parameters of interest in wine quality control.

  16. Realization of a diamond based high density multi electrode array by means of Deep Ion Beam Lithography

    International Nuclear Information System (INIS)

    Picollo, F.; Battiato, A.; Bernardi, E.; Boarino, L.; Enrico, E.; Forneris, J.; Gatto Monticone, D.; Olivero, P.

    2015-01-01

    In the present work we report about a parallel-processing ion beam fabrication technique whereby high-density sub-superficial graphitic microstructures can be created in diamond. Ion beam implantation is an effective tool for the structural modification of diamond: in particular ion-damaged diamond can be converted into graphite, therefore obtaining an electrically conductive phase embedded in an optically transparent and highly insulating matrix. The proposed fabrication process consists in the combination of Deep Ion Beam Lithography (DIBL) and Focused Ion Beam (FIB) milling. FIB micromachining is employed to define micro-apertures in the contact masks consisting of thin (<10 μm) deposited metal layers through which ions are implanted in the sample. A prototypical single-cell biosensor was realized with the above described technique. The biosensor has 16 independent electrodes converging inside a circular area of 20 μm diameter (typical neuroendocrine cells size) for the simultaneous recording of amperometric signals

  17. Use of the smart tongue to monitor mold growth and discriminate between four mold species grown in liquid media

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Guangying, E-mail: zhaogy-user@163.com [Food Safety Key Lab of Zhejiang Province, Department of Food Quality and Safety, Zhejiang Gongshang University, Hangzhou 310035 (China); Lin Xiaona; Dou Wenchao; Tian Shiyi; Deng Shaoping; Shi Jinqin [Food Safety Key Lab of Zhejiang Province, Department of Food Quality and Safety, Zhejiang Gongshang University, Hangzhou 310035 (China)

    2011-04-01

    A novel voltammetric electronic tongue, smart tongue, was employed to monitor the growth of mold and to differentiate between four types of mold grown in liquid medium. Principal component analysis (PCA) was used to extract the relevant information obtained by the smart tongue. Reference growth curves were based on measurements of dry weight and pH. The growth detected by the smart tongue was basically consistent with that observed by the measurement of dry weight and pH. The optimal combinations of electrodes and frequencies for monitoring growth were as follows: for Aspergillus, both the Pt and Au electrodes at 1 Hz, 10 Hz and 100 Hz; for Penicillium, the Pt and W electrodes at 100 Hz; for Mucor, the Pt, Pd and W electrodes at the three frequency segments; for Rhizopus, the Pd, Ti and Ag electrodes at the three frequency segments. The Ag electrode at 10 Hz or 100 Hz frequency could differentiate well between the four types of mold for culturing 6 h in the liquid media. Therefore, the smart tongue has a promising future as a modern rapid analytical technology for the real time detection of the growth of mold and for the classification model of mold.

  18. Use of the smart tongue to monitor mold growth and discriminate between four mold species grown in liquid media

    International Nuclear Information System (INIS)

    Zhao Guangying; Lin Xiaona; Dou Wenchao; Tian Shiyi; Deng Shaoping; Shi Jinqin

    2011-01-01

    A novel voltammetric electronic tongue, smart tongue, was employed to monitor the growth of mold and to differentiate between four types of mold grown in liquid medium. Principal component analysis (PCA) was used to extract the relevant information obtained by the smart tongue. Reference growth curves were based on measurements of dry weight and pH. The growth detected by the smart tongue was basically consistent with that observed by the measurement of dry weight and pH. The optimal combinations of electrodes and frequencies for monitoring growth were as follows: for Aspergillus, both the Pt and Au electrodes at 1 Hz, 10 Hz and 100 Hz; for Penicillium, the Pt and W electrodes at 100 Hz; for Mucor, the Pt, Pd and W electrodes at the three frequency segments; for Rhizopus, the Pd, Ti and Ag electrodes at the three frequency segments. The Ag electrode at 10 Hz or 100 Hz frequency could differentiate well between the four types of mold for culturing 6 h in the liquid media. Therefore, the smart tongue has a promising future as a modern rapid analytical technology for the real time detection of the growth of mold and for the classification model of mold.

  19. Interfacial pH-gradient induced micro-capillary filling with the aid of transverse electrodes arrays in presence of electrical double layer effects

    International Nuclear Information System (INIS)

    Jain, Avi; Chakraborty, Suman

    2010-01-01

    In the present work, we outline the design and analysis of a micro-capillary filling mechanism through the aid of interfacial pH gradients (and hence interfacial tension gradients) generated by employing arrays of transverse electrodes inducing step changes in voltages, in a natural buffer system that requires low power and no synthetic ampholytes. The capillary transport is modulated by a dynamic and non-trivial coupling between the interfacial tension and viscous resistances, as a consequence of the underlying intermolecular interactions. The competing effects of the driving and the retarding forces effectively determine the displacement, velocity and acceleration characteristics of the capillary front, in a dynamically evolving manner. A comprehensive theoretical model of capillary dynamics is developed here to address these issues in details, thereby revealing the combined influence of the interfacial electrochemistry and the applied transverse voltages, as guided by the pertinent fundamental thermodynamic principles governed by free energy considerations and the physico-chemical phenomena over interfacial scales. Non-trivial implications of the pH-gradient driven micro-capillary transport are aptly emphasized, so as to offer significant physical insights on the adopted strategy as a guiding principle for facilitating capillary filling processes by inducing a modulation in the effective interfacial energy. Particular implications on the capillary filling time are also pinpointed, revealing the effectiveness of the adopted design strategy. Finally, a universal scaling relationship of the capillary filling time as a function of the pertinent operating parameters is derived, so as to provide a generalized guideline for implementing the design scheme. A non-dimensional parameter, depending simultaneously on the inter-electrode pitch and the transverse voltage, is identified, which may be kept to a minimal limit within the other operating constraints of the chosen

  20. Galvanic Tongue Stimulation Inhibits Five Basic Tastes Induced by Aqueous Electrolyte Solutions

    Directory of Open Access Journals (Sweden)

    Kazuma Aoyama

    2017-12-01

    Full Text Available Galvanic tongue stimulation (GTS modulates taste sensation. However, the effect of GTS is contingent on the electrode polarity in the proximity of the tongue. If an anodal electrode is attached in the proximity of the tongue, an electrical or metallic taste is elicited. On the other hand, if only cathodal electrode is attached in the proximity of the tongue, the salty taste, which is induced by electrolyte materials, is inhibited. The mechanism of this taste inhibition is not adequately understood. In this study, we aim to demonstrate that the inhibition is cause by ions, which elicit taste and which migrate from the taste sensors on the tongue by GTS. We verified the inhibitory effect of GTS on all five basic tastes induced by electrolyte materials. This technology is effective for virtual reality systems and interfaces to support dietary restrictions. Our findings demonstrate that cathodal-GTS inhibits all the five basic tastes. The results also support our hypothesis that the effects of cathodal-GTS are caused by migrating tasting ions in the mouth.

  1. Bioelectronic tongues: New trends and applications in water and food analysis.

    Science.gov (United States)

    Cetó, Xavier; Voelcker, Nicolas H; Prieto-Simón, Beatriz

    2016-05-15

    Over the last years, there has been an increasing demand for fast, highly sensitive and selective methods of analysis to meet new challenges in environmental monitoring, food safety and public health. In response to this demand, biosensors have arisen as a promising tool, which offers accurate chemical data in a timely and cost-effective manner. However, the difficulty to obtain sensors with appropriate selectivity and sensitivity for a given analyte, and to solve analytical problems which do not require the quantification of a certain analyte, but an overall effect on a biological system (e.g. toxicity, quality indices, provenance, freshness, etc.), led to the concept of electronic tongues as a new strategy to tackle these problems. In this direction, to improve the performance of electronic tongues, and thus to spawn new application fields, biosensors have recently been incorporated to electronic tongue arrays, leading to what is known as bioelectronic tongues. Bioelectronic tongues provide superior performance by combining the capabilities of electronic tongues to derive meaning from complex or imprecise data, and the high selectivity and specificity of biosensors. The result is postulated as a tool that exploits chemometrics to solve biosensors' interference problems, and biosensors to solve electronic tongues' selectivity problems. The review presented herein aims to illustrate the capabilities of bioelectronic tongues as analytical tools, especially suited for screening analysis, with particular emphasis in water analysis and the characterization of food and beverages. After briefly reviewing the key concepts related to the design and principles of electronic tongues, we provide an overview of significant contributions to the field of bioelectronic tongues and their future perspectives. Copyright © 2016. Published by Elsevier B.V.

  2. BrainPort(Registered trademark) Technology Tongue Interface Characterization

    Science.gov (United States)

    2010-03-01

    22 boards in house. … … … … … Experiment Control Workstation HDA with 2000 to 20,000 electrodes ●●● TCP/IP 10/100 Linux-based Control...Defense Advanced Research Projects Agency HD High Density HDA High Density Array IOD Intra-Oral Device IRB Institutional Review Board Electrode

  3. Repeated tongue lift movement induces neuroplasticity in corticomotor control of tongue and jaw muscles in humans

    DEFF Research Database (Denmark)

    Komoda, Yoshihiro; Lida, Takashi; Kothari, Mohit

    2015-01-01

    . EMG recordings from the left and right tongue dorsum and masseter muscles were made at three pressure levels (5kPa, 10kPa, 100% tongue lift), and tongue, masseter, and first dorsal interosseous (FDI) MEPs were measured. There were no significant day-to-day differences in the tongue pressure during...

  4. Ballistic tongue projection in a miniaturized salamander.

    Science.gov (United States)

    Deban, Stephen M; Bloom, Segall V

    2018-05-20

    Miniaturization of body size is often accompanied by peculiarities in morphology that can have functional consequences. We examined the feeding behavior and morphology of the miniaturized plethodontid salamander Thorius, one of the smallest vertebrates, to determine if its performance and biomechanics differ from those of its larger relatives. High-speed imaging and dynamics analysis of feeding at a range of temperatures show that tongue projection in Thorius macdougalli is ballistic and achieves accelerations of up to 600 G with low thermal sensitivity, indicating that tongue projection is powered by an elastic-recoil mechanism. Preceding ballistic projection is an unusual preparatory phase of tongue protrusion, which, like tongue retraction, shows lower performance and higher thermal sensitivity that are indicative of movement being powered directly by muscle shortening. The variability of tongue-projection kinematics and dynamics is comparable to larger ballistic-tongued plethodontids and reveals that Thorius is capable of modulating its tongue movements in response to prey distance. Morphological examination revealed that T. macdougalli possesses a reduced number of myofibers in the tongue muscles, a large projector muscle mass relative to tongue mass, and an unusual folding of the tongue skeleton, compared with larger relatives. Nonetheless, T. macdougalli retains the elaborated collagen aponeuroses in the projector muscle that store elastic energy and a tongue skeleton that is free of direct myofiber insertion, two features that appear to be essential for ballistic tongue projection in salamanders. © 2018 Wiley Periodicals, Inc.

  5. Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes

    International Nuclear Information System (INIS)

    Armengaud, E.; Augier, C.; Benoit, A.; Berge, L.; Bluemer, J.; Broniatowski, A.; Brudanin, V.; Censier, B.; Chardin, G.; Chapellier, M.; Charlieux, F.; Coulter, P.; Cox, G.A.; Defay, X.; De Jesus, M.; Dolgorouki, Y.; Domange, J.; Dumoulin, L.

    2011-01-01

    The EDELWEISS-II Collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The combined use of thermal phonon sensors and charge collection electrodes with an interleaved geometry enables the efficient rejection of γ-induced radioactivity as well as near-surface interactions. A total effective exposure of 384 kg d has been achieved, mostly coming from fourteen months of continuous operation. Five nuclear recoil candidates are observed above 20 keV, while the estimated background is 3.0 events. The result is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 4.4x10 -8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints are also set on models where the WIMP-nucleon scattering is inelastic.

  6. Development of label-free impedimetric platform based on new conductive polyaniline polymer and three-dimensional interdigitated electrode array for biosensor applications

    International Nuclear Information System (INIS)

    Voitechovič, E.; Bratov, A.; Abramova, N.; Razumienė, J.; Kirsanov, D.; Legin, A.; Lakshmi, D.; Piletsky, S.; Whitcombe, M.; Ivanova-Mitseva, P.K.

    2015-01-01

    Graphical abstract: Display Omitted -- Abstract: Novel label-free impedimetric platform based on a three-dimensional interdigitated electrode array (3D-IDEA) sensor and new conductive polymer as a transducer for oxidoreductases is introduced. This platform is cost-effective, simple to construct and miniaturize. Monomer of conductive polymer N-(N’,N’-diethyldithiocarbamoylethylamidoethyl) aniline (AnD) was deposited onto 3D-IDEA by chemical polymerisation. It was found that the polymer film resistance depends on the redox-potential of the solution. For the first time polyAnD was used as enzyme immobilisation matrix. Pyrroloquinolinequinone (PQQ) dependent alcohol and glucose dehydrogenases were immobilized on 3D-IDEA covered with polyAnD by two different methods. 3D-IDEA sensors with enzymes, which were immobilised by physisorption on polyAnD layer, showed specific response in the presence of 1 μM of the corresponding substrates. Obtained results revealed that PQQ dependent dehydrogenases can re-oxidize on polyAnD via direct electron transfer (DET) from enzyme active site to the polymer surface. This process can be monitored by methods of electrochemical impedance spectroscopy (EIS) and chronoamperometry. Presented study shows that EIS method gives a useful tool for research of re-oxidation process and interaction of electroactive enzymes with conducting materials giving information required to construct and develop analytical devices

  7. In-Vivo Characterization of Glassy Carbon Micro-Electrode Arrays for Neural Applications and Histological Analysis of the Brain Tissue

    Science.gov (United States)

    Vomero, Maria

    The aim of this work is to fabricate and characterize glassy carbon Microelectrode Arrays (MEAs) for sensing and stimulating neural activity, and conduct histological analysis of the brain tissue after the implant to determine long-term performance. Neural applications often require robust electrical and electrochemical response over a long period of time, and for those applications we propose to replace the commonly used noble metals like platinum, gold and iridium with glassy carbon. We submit that such material has the potential to improve the performances of traditional neural prostheses, thanks to better charge transfer capabilities and higher electrochemical stability. Great interest and attention is given in this work, in particular, to the investigation of tissue response after several weeks of implants in rodents' brain motor cortex and the associated materials degradation. As part of this work, a new set of devices for Electrocorticography (ECoG) has been designed and fabricated to improve durability and quality of the previous generation of devices, designed and manufactured by the same research group in 2014. In-vivo long-term impedance measurements and brain activity recordings were performed to test the functionality of the neural devices. In-vitro electrical characterization of the carbon electrodes, as well as the study of the adhesion mechanisms between glassy carbon and different substrates is also part of the research described in this book.

  8. Tongues of Men and Angels

    DEFF Research Database (Denmark)

    McGraw, John J.

    2012-01-01

    The accelerating popularity of Charismatic Christianity has brought with it a host of new sensibilities and ritual practices. Glossolalia, or ‘speaking in tongues,’ stands out among these as a particularly dramatic innovation. Typically staid churchgoers, once touched by the Holy Spirit, begin to...

  9. MRI diagnosis of tongue tumors

    International Nuclear Information System (INIS)

    Minowa, Kazuyuki; Abe, Satoru; Ohmori, Keiichi; Hosokawa, Yoichirou; Yamasaki, Michio; Hirano, Masayasu.

    1992-01-01

    MRI studies were performed on 29 patients with tongue tumors. Twenty-six cases were fresh, others were recurrent. Signal intensity of tongue tumor was not characteristic and specific, and it was a low∼iso signal on T1 weighted image (WI), heterogeneously iso∼high signal intensity on T2 WI, heterogeneous enhancement on gadolinium-DTPA enhanced image compared to muscle signal intensity. In 3 of 29 patients, the tongue tumor invaded to the mandible. With regard to the grasping tumor invasion to the mandible, the STIR method was superior to T1, T2 WI of the spin echo method. Dynamic enhanced MR images were performed in 6 of 29 patients. Dynamic change of signal intensity after gadolinium-DTPA administration were assessed with fast low angle shot imaging. On dynamic study at about 20 seconds after gadolinium-DTPA injection, the first signal intensity in the periphery of the tumor gradually began to increase. Maximum signal intensity of the tumor showed at about 70 seconds after gadolinium-DTPA injection. In search from 0 to 5 minutes, after the tongue tumor showed maximum signal intensity, its signal maintain the maximum. Necrotic and peritumorous edema showed a significantly lower and more gradual increase in signal intensity than adjacent neoplastic tissue on dynamic enhanced MRI. (author)

  10. Electronic Nose and Electronic Tongue

    Science.gov (United States)

    Bhattacharyya, Nabarun; Bandhopadhyay, Rajib

    Human beings have five senses, namely, vision, hearing, touch, smell and taste. The sensors for vision, hearing and touch have been developed for several years. The need for sensors capable of mimicking the senses of smell and taste have been felt only recently in food industry, environmental monitoring and several industrial applications. In the ever-widening horizon of frontier research in the field of electronics and advanced computing, emergence of electronic nose (E-Nose) and electronic tongue (E-Tongue) have been drawing attention of scientists and technologists for more than a decade. By intelligent integration of multitudes of technologies like chemometrics, microelectronics and advanced soft computing, human olfaction has been successfully mimicked by such new techniques called machine olfaction (Pearce et al. 2002). But the very essence of such research and development efforts has centered on development of customized electronic nose and electronic tongue solutions specific to individual applications. In fact, research trends as of date clearly points to the fact that a machine olfaction system as versatile, universal and broadband as human nose and human tongue may not be feasible in the decades to come. But application specific solutions may definitely be demonstrated and commercialized by modulation in sensor design and fine-tuning the soft computing solutions. This chapter deals with theory, developments of E-Nose and E-Tongue technology and their applications. Also a succinct account of future trends of R&D efforts in this field with an objective of establishing co-relation between machine olfaction and human perception has been included.

  11. Electrical responses and spontaneous activity of human iPS-derived neuronal networks characterized for three-month culture with 4096-electrode arrays

    Directory of Open Access Journals (Sweden)

    Hayder eAmin

    2016-03-01

    Full Text Available The recent availability of human induced pluripotent stem cells (hiPSCs holds great promise as a novel source of human-derived neurons for cell and tissue therapies as well as for in vitro drug screenings that might replace the use of animal models. However, there is still a considerable lack of knowledge on the functional properties of hiPSC-derived neuronal networks, thus limiting their application. Here, upon optimization of cell culture protocols, we demonstrate that both spontaneous and evoked electrical spiking activities of these networks can be characterized on-chip by taking advantage of the resolution provided by CMOS multielectrode arrays (CMOS-MEAs. These devices feature a large and closely-spaced array of 4096 simultaneously recording electrodes and multi-site on-chip electrical stimulation. Our results show that networks of human-derived neurons can respond to electrical stimulation with a physiological repertoire of spike waveforms after three months of cell culture, a period of time during which the network undergoes the expression of developing patterns of spontaneous spiking activity. To achieve this, we have investigated the impact on the network formation and on the emerging network-wide functional properties induced by different biochemical substrates, i.e. poly-dl-ornithine (PDLO, poly-l-ornithine (PLO, and polyethylenimine (PEI, that were used as adhesion promoters for the cell culture. Interestingly, we found that neuronal networks grown on PDLO coated substrates show significantly higher spontaneous firing activity, reliable responses to low-frequency electrical stimuli, and an appropriate level of PSD-95 that may denote a physiological neuronal maturation profile and synapse stabilization. However, our results also suggest that even three-month culture might not be sufficient for human-derived neuronal network maturation. Taken together, our results highlight the tight relationship existing between substrate coatings

  12. Novel modulatory effects of neurosteroids and benzodiazepines on excitatory and inhibitory neurons excitability: a multi-electrode array (MEA recording study"

    Directory of Open Access Journals (Sweden)

    Giulia ePuia

    2012-11-01

    Full Text Available The balance between glutamate- and GABA-mediated neurotransmission in the brain is fundamental in the nervous system, but it is regulated by the ‘tonic’ release of a variety of endogenous factors. One such important group of molecules are the neurosteroids (NSs which, similarly to benzodiazepines (BDZs, enhance GABAergic neurotransmission. The purpose of our work was to investigate, at in-vivo physiologically relevant concentrations, the effects of NSs and BDZs as GABA modulators on dissociated neocortical neuron networks grown in long-term culture. We used a multi-electrode array (MEA recording technique and a novel analysis that was able to both identify the action potentials of engaged excitatory and inhibitory neurons and to detect drug-induced network up-states (burst. We found that the NSs tetrahydrodeoxycorticosterone (THDOC and allopregnanolone (ALLO applied at low nM concentrations, produced different modulatory effects on the two neuronal clusters. Conversely, at high concentrations (1 µM, both NSs, decreased excitatory and inhibitory neuron cluster excitability; however, even several hours after washout, the excitability of inhibitory neurons continued to be depressed, leading to a network long term depression (LTD. The BDZs clonazepam (CLZ and midazolam (MDZ also decreased the network excitability, but only MDZ caused LTD of inhibitory neuron cluster. To investigate the origin of the LTD after MDZ application, we tested finasteride (FIN, an inhibitor of endogenous NSs synthesis. FIN did not prevent the LTD induced by MDZ, but surprisingly induced it after application of CLZ. The significance and possible mechanisms underlying these LTD effects of NSs and BDZs are discussed. Taken together, our results not only demonstrate that ex-vivo networks show a sensitivity to NSs and BDZs comparable to that expressed in vivo, but also provide a new global in-vitro description that can help in understanding their activity in more complex

  13. Corticobulbar motor evoked potentials from tongue muscles used as a control in cervical spinal surgery

    Directory of Open Access Journals (Sweden)

    Dong-Gun Kim

    Full Text Available Objective: Motor evoked potentials (MEPs changes might be caused to the non-surgically induced factors during cervical spinal surgery. Therefore, control MEPs recorded cranially to the exit of the C5 root are highly recommendable in cervical spinal surgery. We studied whether corticobulbar MEPs (C-MEPs from tongue muscle could be used as a control MEPs in cervical spinal surgery. Methods: Twenty-five consecutive cervical spinal surgeries were analyzed. Stimulation of motor area for tongue was done by subcutaneous electrodes placed at C3/C4 (10–20 EEG System, and recording was done from both sides of tongue. Results: C-MEPs were recorded successfully 24 out of the 25 (96% tested patients. Forty-six out of fifty MEPs (92% from tongue muscles were monitorable from the baseline. In two patients, we could obtain only unilateral C-MEPs. Mean MEPs latencies obtained from the left and right side of the tongue were 11.5 ± 1 ms and 11.5 ± 0.8 ms, respectively. Conclusions: Monitoring C-MEPs from tongue muscles might be useful control in cervical spinal surgery. They were easily elicited and relatively free from phenomenon of peripheral stimulation of the hypoglossal nerves. Significance: This is first study to identify the usefulness of C-MEPs as a control of cervical spinal surgery. Keywords: Intraoperative neurophysiological monitoring, Motor-evoked potential, Corticospinal tract, Corticobulbar MEPs, Hypoglossal nerve

  14. Ossifying chondrolipoma of the tongue

    Directory of Open Access Journals (Sweden)

    Tasić Desanka

    2012-01-01

    Full Text Available Introduction. Chondrolipomas and osteolipomas are uncommon variants of lipomatous tumors. Case report. We presented a 60-year-old woman with ossifying chondrolipoma of the tongue. Clinical examination revealed a firm nodular mass, located in the midline of the posterior region on the dorsal surface of the tongue. Histologically, the lesion was well-delimited showing areas of mature adipocytes arranged in lobules and separated by fibrous connective tissue septa, islands of mature cartilaginous tissue and osseous metaplasia. Trabeculae of lamellar bone within a fibro-fatty background were visible throughout the tumor. The cartilaginous areas merging centrally with bone formation and fatty marrow tissue were present, as well as the hematopoietic elements in the fatty marrow. The bone forming was found to be through both membranous and enchondral mechanisms. Conclusion. Ossifying chrondrolipoma with hematopoietic elements is extremely unusual lesion. This interesting entity should be kept in mind in the differential diagnosis of lingual lesions.

  15. Common tongue conditions in primary care.

    Science.gov (United States)

    Reamy, Brian V; Derby, Richard; Bunt, Christopher W

    2010-03-01

    Although easily examined, abnormalities of the tongue can present a diagnostic and therapeutic dilemma for physicians. Recognition and diagnosis require a thorough history, including onset and duration, antecedent symptoms, and tobacco and alcohol use. Examination of tongue morphology and a careful assessment for lymphadenopathy are also important. Geographic tongue, fissured tongue, and hairy tongue are the most common tongue problems and do not require treatment. Median rhomboid glossitis is usually associated with a candidal infection and responds to topical antifungals. Atrophic glossitis is often linked to an underlying nutritional deficiency of iron, folic acid, vitamin B12, riboflavin, or niacin and resolves with correction of the underlying condition. Oral hairy leukoplakia, which can be a marker for underlying immunodeficiency, is caused by the Epstein-Barr virus and is treated with oral antivirals. Tongue growths usually require biopsy to differentiate benign lesions (e.g., granular cell tumors, fibromas, lymphoepithelial cysts) from premalignant leukoplakia or squamous cell carcinoma. Burning mouth syndrome often involves the tongue and has responded to treatment with alpha-lipoic acid, clonazepam, and cognitive behavior therapy in controlled trials. Several trials have also confirmed the effectiveness of surgical division of tongue-tie (ankyloglossia), in the context of optimizing the success of breastfeeding compared with education alone. Tongue lesions of unclear etiology may require biopsy or referral to an oral and maxillofacial surgeon, head and neck surgeon, or a dentist experienced in oral pathology.

  16. Quantitative Determination of Spring Water Quality Parameters via Electronic Tongue

    Directory of Open Access Journals (Sweden)

    Noèlia Carbó

    2017-12-01

    Full Text Available The use of a voltammetric electronic tongue for the quantitative analysis of quality parameters in spring water is proposed here. The electronic voltammetric tongue consisted of a set of four noble electrodes (iridium, rhodium, platinum, and gold housed inside a stainless steel cylinder. These noble metals have a high durability and are not demanding for maintenance, features required for the development of future automated equipment. A pulse voltammetry study was conducted in 83 spring water samples to determine concentrations of nitrate (range: 6.9–115 mg/L, sulfate (32–472 mg/L, fluoride (0.08–0.26 mg/L, chloride (17–190 mg/L, and sodium (11–94 mg/L as well as pH (7.3–7.8. These parameters were also determined by routine analytical methods in spring water samples. A partial least squares (PLS analysis was run to obtain a model to predict these parameter. Orthogonal signal correction (OSC was applied in the preprocessing step. Calibration (67% and validation (33% sets were selected randomly. The electronic tongue showed good predictive power to determine the concentrations of nitrate, sulfate, chloride, and sodium as well as pH and displayed a lower R2 and slope in the validation set for fluoride. Nitrate and fluoride concentrations were estimated with errors lower than 15%, whereas chloride, sulfate, and sodium concentrations as well as pH were estimated with errors below 10%.

  17. Direct growth of metal-organic frameworks thin film arrays on glassy carbon electrode based on rapid conversion step mediated by copper clusters and hydroxide nanotubes for fabrication of a high performance non-enzymatic glucose sensing platform.

    Science.gov (United States)

    Shahrokhian, Saeed; Khaki Sanati, Elnaz; Hosseini, Hadi

    2018-07-30

    The direct growth of self-supported metal-organic frameworks (MOFs) thin film can be considered as an effective strategy for fabrication of the advanced modified electrodes in sensors and biosensor applications. However, most of the fabricated MOFs-based sensors suffer from some drawbacks such as time consuming for synthesis of MOF and electrode making, need of a binder or an additive layer, need of expensive equipment and use of hazardous solvents. Here, a novel free-standing MOFs-based modified electrode was fabricated by the rapid direct growth of MOFs on the surface of the glassy carbon electrode (GCE). In this method, direct growth of MOFs was occurred by the formation of vertically aligned arrays of Cu clusters and Cu(OH) 2 nanotubes, which can act as both mediator and positioning fixing factor for the rapid formation of self-supported MOFs on GCE surface. The effect of both chemically and electrochemically formed Cu(OH) 2 nanotubes on the morphological and electrochemical performance of the prepared MOFs were investigated. Due to the unique properties of the prepared MOFs thin film electrode such as uniform and vertically aligned structure, excellent stability, high electroactive surface area, and good availability to analyte and electrolyte diffusion, it was directly used as the electrode material for non-enzymatic electrocatalytic oxidation of glucose. Moreover, the potential utility of this sensing platform for the analytical determination of glucose concentration was evaluated by the amperometry technique. The results proved that the self-supported MOFs thin film on GCE is a promising electrode material for fabricating and designing non-enzymatic glucose sensors. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Detection of Taste Change of Bovine and Goat Milk in Room Ambient Using Electronic Tongue

    Directory of Open Access Journals (Sweden)

    Imam Tazi

    2017-11-01

    Full Text Available An electronic tongue (e-tongue based on an array of lipid/polymer membranes has been successfully developed for measuring the taste evolution of natural milk. The e-tongue consisted of 16 different lipid/polymer membranes combined with or without a pH sensor. The natural milk of bovine and goat were purchased from the local farming store in Malang-Indonesia. The taste measurement was carried out, from fresh (0 h to stale (12 h, every two hours under room ambient without any treatment. The responses of the e-tongue were evaluated using a Principal Component Analysis (PCA and a Linear Discriminant Analysis (LDA. From PCA results, the taste of both milk samples tends to change by time although some groups show a partial overlapping. LDA results show the high precision of the e-tongue in clustering taste evolution. The correctly classified groups after the cross-validation procedure were achieved 95.7 and 87.1% for bovine and goat milk, respectively. The improvement of the classification using LDA was obtained by adding data from a pH sensor of each measurement as 100 and 98.6% for bovine and goat milk, respectively. This work indicates that the lab-made e-tongue may be useful to predict the quality of natural milk for the food industry.

  19. Pd-MnO2 nanoparticles/TiO2 nanotube arrays (NTAs) photo-electrodes photo-catalytic properties and their ability of degrading Rhodamine B under visible light.

    Science.gov (United States)

    Thabit, Mohamed; Liu, Huiling; Zhang, Jian; Wang, Bing

    2017-10-01

    Pd-MnO 2 /TiO 2 nanotube arrays (NTAs) photo-electrodes were successfully fabricated via anodization and electro deposition subsequently; the obtained Pd-MnO 2 /TiO 2 NTAs photo electrodes were analyzed by scanning electron microscopy (SEM), X-ray diffraction (XRD) and characterized accordingly. Moreover, the light harvesting and absorption properties were investigated via ultraviolet-visible diffuse reflectance spectrum (DRS); photo degradation efficiency was investigated via analyzing the photo catalytic degradation of Rhodamine B under visible illumination (xenon light). The performed analyses illustrated that Pd-MnO 2 codoped particles were successfully deposited onto the surface of the TiO 2 nanotube arrays; DRS results showed significant improvement in visible light absorption which was between 400 and 700nm. Finally, the photo catalytic degradation efficiency results of the designated organic pollutant (Rhodamine B) illustrated a superior photocatalytic (PC) efficiency of approximately 95% compared to the bare TiO 2 NTAs, which only exhibited a photo catalytic degradation efficiency of approximately 61%, thus it indicated the significant enhancement of the light absorption properties of fabricated photo electrodes and their yield of OH radicals. Copyright © 2017. Published by Elsevier B.V.

  20. Effects of tongue cleaning on bacterial flora in tongue coating and dental plaque: a crossover study.

    Science.gov (United States)

    Matsui, Miki; Chosa, Naoyuki; Shimoyama, Yu; Minami, Kentaro; Kimura, Shigenobu; Kishi, Mitsuo

    2014-01-14

    The effects of tongue cleaning on reconstruction of bacterial flora in dental plaque and tongue coating itself are obscure. We assessed changes in the amounts of total bacteria as well as Fusobacterium nucleatum in tongue coating and dental plaque specimens obtained with and without tongue cleaning. We conducted a randomized examiner-blind crossover study using 30 volunteers (average 23.7 ± 3.2 years old) without periodontitis. After dividing randomly into 2 groups, 1 group was instructed to clean the tongue, while the other did not. On days 1 (baseline), 3, and 10, tongue coating and dental plaque samples were collected after recording tongue coating score (Winkel tongue coating index: WTCI). After a washout period of 3 weeks, the same examinations were performed with the subjects allocated to the alternate group. Genomic DNA was purified from the samples and applied to SYBR® Green-based real-time PCR to quantify the amounts of total bacteria and F. nucleatum. After 3 days, the WTCI score recovered to baseline, though the amount of total bacteria in tongue coating was significantly lower as compared to the baseline. In plaque samples, the bacterial amounts on day 3 and 10 were significantly lower than the baseline with and without tongue cleaning. Principal component analysis showed that variations of bacterial amounts in the tongue coating and dental plaque samples were independent from each other. Furthermore, we found a strong association between amounts of total bacteria and F. nucleatum in specimens both. Tongue cleaning reduced the amount of bacteria in tongue coating. However, the cleaning had no obvious contribution to inhibit dental plaque formation. Furthermore, recovery of the total bacterial amount induced an increase in F. nucleatum in both tongue coating and dental plaque. Thus, it is recommended that tongue cleaning and tooth brushing should both be performed for promoting oral health.

  1. Electrical Neural Stimulation and Simultaneous in Vivo Monitoring with Transparent Graphene Electrode Arrays Implanted in GCaMP6f Mice.

    Science.gov (United States)

    Park, Dong-Wook; Ness, Jared P; Brodnick, Sarah K; Esquibel, Corinne; Novello, Joseph; Atry, Farid; Baek, Dong-Hyun; Kim, Hyungsoo; Bong, Jihye; Swanson, Kyle I; Suminski, Aaron J; Otto, Kevin J; Pashaie, Ramin; Williams, Justin C; Ma, Zhenqiang

    2018-01-23

    Electrical stimulation using implantable electrodes is widely used to treat various neuronal disorders such as Parkinson's disease and epilepsy and is a widely used research tool in neuroscience studies. However, to date, devices that help better understand the mechanisms of electrical stimulation in neural tissues have been limited to opaque neural electrodes. Imaging spatiotemporal neural responses to electrical stimulation with minimal artifact could allow for various studies that are impossible with existing opaque electrodes. Here, we demonstrate electrical brain stimulation and simultaneous optical monitoring of the underlying neural tissues using carbon-based, fully transparent graphene electrodes implanted in GCaMP6f mice. Fluorescence imaging of neural activity for varying electrical stimulation parameters was conducted with minimal image artifact through transparent graphene electrodes. In addition, full-field imaging of electrical stimulation verified more efficient neural activation with cathode leading stimulation compared to anode leading stimulation. We have characterized the charge density limitation of capacitive four-layer graphene electrodes as 116.07-174.10 μC/cm 2 based on electrochemical impedance spectroscopy, cyclic voltammetry, failure bench testing, and in vivo testing. This study demonstrates the transparent ability of graphene neural electrodes and provides a method to further increase understanding and potentially improve therapeutic electrical stimulation in the central and peripheral nervous systems.

  2. Tongue force in patients with myasthenia gravis

    NARCIS (Netherlands)

    Weijnen, FG; Kuks, JBM; van der Glas, HW; Wassenberg, MWM; Bosman, F

    2000-01-01

    Objectives - The aim was to study tongue force in patients with bulbar myasthenia gravis and compare it with that of patients with ocular myasthenia gravis, patients in clinical remission who previously suffered from bulbar myasthenia gravis, and healthy subjects. Material and methods - Tongue force

  3. Tongue controlled computer game: A new approach for rehabilitation of tongue motor function

    DEFF Research Database (Denmark)

    Kothari, Mohit; Svensson, Peter; Jensen, Jim

    2014-01-01

    Objective: To investigate the influence of tongue-disability, age and gender on motor performance for a tongue training paradigm involving playing a computer game using the Tongue Drive System (TDS). Design: Two controlled observational studies. Setting: A neurorehabilitation center and a dental...... school. Participants: In Study 1, eleven tongue-disabled patients with symptoms of dysphagia and dysarthria and 11 age-and sex-matched controls participated in tongue training. In Study 2, 16 healthy elderly and 16 healthy young participants volunteered. Intervention: In study 1 and study 2, the tongue....... Subject-based reports of motivation, fun, pain and fatigue evaluated on 0-10 numerical rating scales (NRS) were compared between groups. Results: In study 1, tongue-disabled patients performed poorer than healthy controls (P=0.005) and with a trend of a gender difference (P=0.046). In study 2, healthy...

  4. Paleoecology of the Niland Tongue

    Energy Technology Data Exchange (ETDEWEB)

    Robbins, E.I.

    1987-01-01

    The swamp or paludal ecosystem is preserved in coals and carbonaceous shales. Remains of organisms of the swamp communities consist of bacteria and fungi; algae; invertebrates such as pelecypods, gastropods, ostracodes, and insects; vertebrates such as a hard-shelled turtle and crocodiles; and vascular plant remains. Aquatic communities are found in dark shale and are represented by the remains of bacteria and fungi; algae; invertebrates such as pelecypods, gastropods, and insects; and vertebrates such as crocodiles, fish, and a soft-shelled turtle. No vascular macrophytes (rooted aquatic vegetation) could be identified in the pollen and spore assemblage. Charophytes are abundant and show that colonies of the aquatic alga lived on the lake bottoms. The great variety of organisms suggests that the environment had a high input of nutrients. The phosphate-rich Phosphoria Formation, which could serve as a good source of nutrients, cropped out in the watershed of the Niland Tongue basin. The ostracode-crocodile association, calcareous charophytes, and good preservation of plant tissues and palynomorphs put limits on the alkaline geochemical environment in which the lacustrine rocks were deposited. The palynomorphs in the Niland Tongue rocks are dark yellow and light brown in color. These colors suggest that rocks containing them have been buried deeper in the past than they are today.

  5. A facile one-step synthesis of Mn{sub 3}O{sub 4} nanoparticles-decorated TiO{sub 2} nanotube arrays as high performance electrode for supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jianfang [School of Materials Science and Engineering, Hefei University of Technology, Hefei 230009 (China); Wang, Yan [School of Materials Science and Engineering, Hefei University of Technology, Hefei 230009 (China); Key Laboratory of Advance Functional Materials and Devices of Anhui Province, Hefei 230009 (China); Qin, Yongqiang, E-mail: albon@hfut.edu.cn [School of Materials Science and Engineering, Hefei University of Technology, Hefei 230009 (China); Key Laboratory of Advance Functional Materials and Devices of Anhui Province, Hefei 230009 (China); Yu, Cuiping [School of Materials Science and Engineering, Hefei University of Technology, Hefei 230009 (China); Cui, Lihua [School of Materials Science and Engineering, Hefei University of Technology, Hefei 230009 (China); School of Materials Science and Engineering, Beifang University of Nationalities, Yinchuan 750021 (China); Shu, Xia [School of Materials Science and Engineering, Hefei University of Technology, Hefei 230009 (China); Cui, Jiewu; Zheng, Hongmei; Zhang, Yong [School of Materials Science and Engineering, Hefei University of Technology, Hefei 230009 (China); Key Laboratory of Advance Functional Materials and Devices of Anhui Province, Hefei 230009 (China); Wu, Yucheng, E-mail: ycwu@hfut.edu.cn [School of Materials Science and Engineering, Hefei University of Technology, Hefei 230009 (China); Key Laboratory of Advance Functional Materials and Devices of Anhui Province, Hefei 230009 (China)

    2017-02-15

    Via a facile one-step chemical bath deposition route, homogeneously dispersed Mn{sub 3}O{sub 4} nanoparticles have been successfully deposited onto the inner surface of TiO{sub 2} nanotube arrays (TNAs). The content and size of Mn{sub 3}O{sub 4} can be controlled by changing the deposition time. Field emission scanning electron microscopy and transmission electron microscopy analysis reveal the morphologies structures of Mn{sub 3}O{sub 4}/TNAs composites. The crystal-line structures are characterized by the X-ray diffraction patterns and Raman spectra. X-ray photoelectron spectroscopy further confirms the valence states of the sample elements. The electrochemical properties of Mn{sub 3}O{sub 4}/TNAs electrodes are systematically investigated by the combine use of cyclic voltammetry, galvanostatic charge-discharge and electrochemical impedance spectroscopy. The resulting Mn{sub 3}O{sub 4}/TNAs electrode prepared by deposition time of 3 h shows the highest specific capacitance of 570 F g{sup −1} at a current density of 1 A g{sup −1}. And it also shows an excellent long-term cycling stability at a current density of 5 A g{sup −1}, which remaining 91.8% of the initial capacitance after 2000 cycles. Thus this kind of Mn{sub 3}O{sub 4} nanoparticles decorated TNAs may be considered as an alternative promising candidate for high performance supercapacitor electrodes. - Graphical abstract: Mn{sub 3}O{sub 4} nanoparticles have been uniformly deposited onto the inner surfaces of TiO{sub 2} nanotube arrays through a facile one-step chemical bath deposition method. As electrodes for supercapacitors, they exhibit a relatively high specific capacity and excellent cycling stability. - Highlights: • Mn{sub 3}O{sub 4} nanoparticles have been deposited onto TiO{sub 2} nanotube arrays by chemical bath deposition. • The Mn{sub 3}O{sub 4}/TNAs exhibits a highest specific capacitance of 570 F g{sup –1} at a current density of 1 A g{sup –1}. • The Mn{sub 3}O{sub 4}/TNAs

  6. Immediate effects of tongue trills associated with transcutaneous electrical nerve stimulation (TENS).

    Science.gov (United States)

    Fabron, Eliana Maria Gradim; Petrini, Andressa Schweitzer; Cardoso, Vanessa de Moraes; Batista, João Carlos Torgal; Motonaga, Suely Mayumi; Marino, Viviane Cristina de Castro

    2017-06-08

    To investigate vocal quality variability after applying tongue trills associated with transcutaneous electrical nerve stimulation (TENS) on the larynx of women with normal laryngeal function. Additionally, to verify the effect of this technique over time on voice quality. Participants were 40 women (average 23.4 years) without vocal complaints. The procedure involved tongue trills with or without TENS for 3 minutes, rest and repeating the technique for another 2 minutes. The participants' voices were recorded before (Pre), after three minutes (Post 3min) and after two additional minutes (Post 5min) applying the technique. TENS with two electrodes was used on the thyroid cartilage. Self-assessment, acoustic and perceptual analysis were performed. When comparing tongue trills in isolation and associated with TENS, a greater sense of stability in phonation (self-assessment) and improvement in voice quality (perceptual evaluation) was observed in the combination technique. There was no statistical difference in acoustics findings between tongue trills in isolation and associated with TENS. When comparing the time effect of tongue trills with TENS in self-assessment there was a perception of less muscle tension (3min) and greater comfort during phonation (5 min); in the acoustic analysis, there was an increase of F0 (3 and 5 min) and intensity (5 min) when compared to Pre-moment; in the perceptual evaluation, better voice quality (3min). Comparing tongue trills in isolation and associated with TENS, there were changes in the comfort and muscle tension perception, as well as in vocal quality. On the other hand, tongue trills associated with TENS performed in 3 or 5 minutes resulted in beneficial effects on the voice identified in the assessments.

  7. Visualized attribute analysis approach for characterization and quantification of rice taste flavor using electronic tongue

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Lin; Hu, Xianqiao [Rice Product Quality Supervision and Inspection Center, Ministry of Agriculture, China National Rice Research Institute, Hangzhou 310006 (China); Tian, Shiyi; Deng, Shaoping [College of Food Science and Biotechnology, Zhejiang Gongshang University, Hangzhou 310035 (China); Zhu, Zhiwei, E-mail: 615834652@qq.com [Rice Product Quality Supervision and Inspection Center, Ministry of Agriculture, China National Rice Research Institute, Hangzhou 310006 (China)

    2016-05-05

    This paper deals with a novel visualized attributive analysis approach for characterization and quantification of rice taste flavor attributes (softness, stickiness, sweetness and aroma) employing a multifrequency large-amplitude pulse voltammetric electronic tongue. Data preprocessing methods including Principal Component Analysis (PCA) and Fast Fourier Transform (FFT) were provided. An attribute characterization graph was represented for visualization of the interactive response in which each attribute responded by specific electrodes and frequencies. The model was trained using signal data from electronic tongue and attribute scores from artificial evaluation. The correlation coefficients for all attributes were over 0.9, resulting in good predictive ability of attributive analysis model preprocessed by FFT. This approach extracted more effective information about linear relationship between electronic tongue and taste flavor attribute. Results indicated that this approach can accurately quantify taste flavor attributes, and can be an efficient tool for data processing in a voltammetric electronic tongue system. - Graphical abstract: Schematic process for visualized attributive analysis approach using multifrequency large-amplitude pulse voltammetric electronic tongue for determination of rice taste flavor attribute. (a) sample; (b) sensors in electronic tongue; (c) excitation voltage program and response current signal from MLAPS; (d) similarity data matrix by data preprocessing and similarity extraction; (e) feature data matrix of attribute; (f) attribute characterization graph; (g) attribute scores predicted by the model. - Highlights: • Multifrequency large-amplitude pulse voltammetric electronic tongue was used. • A visualized attributive analysis approach was created as an efficient tool for data processing. • Rice taste flavor attribute was determined and predicted. • The attribute characterization graph was represented for visualization of the

  8. Using speech recognition to enhance the Tongue Drive System functionality in computer access.

    Science.gov (United States)

    Huo, Xueliang; Ghovanloo, Maysam

    2011-01-01

    Tongue Drive System (TDS) is a wireless tongue operated assistive technology (AT), which can enable people with severe physical disabilities to access computers and drive powered wheelchairs using their volitional tongue movements. TDS offers six discrete commands, simultaneously available to the users, for pointing and typing as a substitute for mouse and keyboard in computer access, respectively. To enhance the TDS performance in typing, we have added a microphone, an audio codec, and a wireless audio link to its readily available 3-axial magnetic sensor array, and combined it with a commercially available speech recognition software, the Dragon Naturally Speaking, which is regarded as one of the most efficient ways for text entry. Our preliminary evaluations indicate that the combined TDS and speech recognition technologies can provide end users with significantly higher performance than using each technology alone, particularly in completing tasks that require both pointing and text entry, such as web surfing.

  9. Piezoelectric transducer array microspeaker

    KAUST Repository

    Carreno, Armando Arpys Arevalo

    2016-12-19

    In this paper we present the fabrication and characterization of a piezoelectric micro-speaker. The speaker is an array of micro-machined piezoelectric membranes, fabricated on silicon wafer using advanced micro-machining techniques. Each array contains 2n piezoelectric transducer membranes, where “n” is the bit number. Every element of the array has a circular shape structure. The membrane is made out four layers: 300nm of platinum for the bottom electrode, 250nm or lead zirconate titanate (PZT), a top electrode of 300nm and a structural layer of 50

  10. A High Sensitivity IDC-Electronic Tongue Using Dielectric/Sensing Membranes with Solvatochromic Dyes

    Directory of Open Access Journals (Sweden)

    Md. Rajibur Rahaman Khan

    2016-05-01

    Full Text Available In this paper, an electronic tongue/taste sensor array containing different interdigitated capacitor (IDC sensing elements to detect different types of tastes, such as sweetness (glucose, saltiness (NaCl, sourness (HCl, bitterness (quinine-HCl, and umami (monosodium glutamate is proposed. We present for the first time an IDC electronic tongue using sensing membranes containing solvatochromic dyes. The proposed highly sensitive (30.64 mV/decade sensitivity IDC electronic tongue has fast response and recovery times of about 6 s and 5 s, respectively, with extremely stable responses, and is capable of linear sensing performance (R2 ≈ 0.985 correlation coefficient over the wide dynamic range of 1 µM to 1 M. The designed IDC electronic tongue offers excellent reproducibility, with a relative standard deviation (RSD of about 0.029. The proposed device was found to have better sensing performance than potentiometric-, cascoded compatible lateral bipolar transistor (C-CLBT-, Electronic Tongue (SA402-, and fiber-optic-based taste sensing systems in what concerns dynamic range width, response time, sensitivity, and linearity. Finally, we applied principal component analysis (PCA to distinguish between various kinds of taste in mixed taste compounds.

  11. Integrated, paper-based potentiometric electronic tongue for the analysis of beer and wine

    International Nuclear Information System (INIS)

    Nery, Emilia Witkowska; Kubota, Lauro T.

    2016-01-01

    The following manuscript details the stages of construction of a novel paper-based electronic tongue with an integrated Ag/AgCl reference, which can operate using a minimal amount of sample (40 μL). First, we optimized the fabrication procedure of silver electrodes, testing a set of different methodologies (electroless plating, use of silver nanoparticles and commercial silver paints). Later a novel, integrated electronic tongue system was assembled with the use of readily available materials such as paper, wax, lamination sheets, bleach etc. New system was thoroughly characterized and the ion-selective potentiometric sensors presented performance close to theoretical. An electronic tongue, composed of electrodes sensitive to sodium, calcium, ammonia and a cross-sensitive, anion-selective electrode was used to analyze 34 beer samples (12 types, 19 brands). This system was able to discriminate beers from different brands, and types, indicate presence of stabilizers and antioxidants, dyes or even unmalted cereals and carbohydrates added to the fermentation wort. Samples could be classified by type of fermentation (low, high) and system was able to predict pH and in part also alcohol content of tested beers. In the next step sample volume was minimalized by the use of paper sample pads and measurement in flow conditions. In order to test the impact of this advancement a four electrode system, with cross-sensitive (anion-selective, cation-selective, Ca"2"+/Mg"2"+, K"+/Na"+) electrodes was applied for the analysis of 11 types of wine (4 types of grapes, red/white, 3 countries). Proposed matrix was able to group wines produced from different varieties of grapes (Chardonnay, Americanas, Malbec, Merlot) using only 40 μL of sample. Apart from that, storage stability studies were performed using a multimeter, therefore showing that not only fabrication but also detection can be accomplished by means of off-the-shelf components. This manuscript not only describes new

  12. Integrated, paper-based potentiometric electronic tongue for the analysis of beer and wine

    Energy Technology Data Exchange (ETDEWEB)

    Nery, Emilia Witkowska, E-mail: ewitkowskanery@ichf.edu.pl [Department of Analytical Chemistry, Institute of Chemistry – UNICAMP, P.O. Box 6154, 13084-971 Campinas, SP (Brazil); National Institute of Science and Technology in Bioanalytics, Institute of Chemistry – UNICAMP, P.O. Box 6154, Campinas (Brazil); Kubota, Lauro T. [Department of Analytical Chemistry, Institute of Chemistry – UNICAMP, P.O. Box 6154, 13084-971 Campinas, SP (Brazil); National Institute of Science and Technology in Bioanalytics, Institute of Chemistry – UNICAMP, P.O. Box 6154, Campinas (Brazil)

    2016-04-28

    The following manuscript details the stages of construction of a novel paper-based electronic tongue with an integrated Ag/AgCl reference, which can operate using a minimal amount of sample (40 μL). First, we optimized the fabrication procedure of silver electrodes, testing a set of different methodologies (electroless plating, use of silver nanoparticles and commercial silver paints). Later a novel, integrated electronic tongue system was assembled with the use of readily available materials such as paper, wax, lamination sheets, bleach etc. New system was thoroughly characterized and the ion-selective potentiometric sensors presented performance close to theoretical. An electronic tongue, composed of electrodes sensitive to sodium, calcium, ammonia and a cross-sensitive, anion-selective electrode was used to analyze 34 beer samples (12 types, 19 brands). This system was able to discriminate beers from different brands, and types, indicate presence of stabilizers and antioxidants, dyes or even unmalted cereals and carbohydrates added to the fermentation wort. Samples could be classified by type of fermentation (low, high) and system was able to predict pH and in part also alcohol content of tested beers. In the next step sample volume was minimalized by the use of paper sample pads and measurement in flow conditions. In order to test the impact of this advancement a four electrode system, with cross-sensitive (anion-selective, cation-selective, Ca{sup 2+}/Mg{sup 2+}, K{sup +}/Na{sup +}) electrodes was applied for the analysis of 11 types of wine (4 types of grapes, red/white, 3 countries). Proposed matrix was able to group wines produced from different varieties of grapes (Chardonnay, Americanas, Malbec, Merlot) using only 40 μL of sample. Apart from that, storage stability studies were performed using a multimeter, therefore showing that not only fabrication but also detection can be accomplished by means of off-the-shelf components. This manuscript not only

  13. Influence of the ability to roll the tongue and tongue-training parameters on oral motor performance and learning

    DEFF Research Database (Denmark)

    Kothari, Mohit; Svensson, Peter; Basic, Aida

    2011-01-01

    OBJECTIVE: Training of tongue function is an important part of rehabilitation of patients with brain damage. A standardized tongue-training task has been shown to induce cortical plasticity. This study tested the possible influence of the natural ability to roll the tongue and modulations of tongue...

  14. Growth of highly mesoporous CuCo2O4@C core-shell arrays as advanced electrodes for high-performance supercapacitors

    Science.gov (United States)

    Yan, Hailong; Lu, Yang; Zhu, Kejia; Peng, Tao; Liu, Xianming; Liu, Yunxin; Luo, Yongsong

    2018-05-01

    A series of CuCo2O4 nanostructures with different morphologies were prepared by a hydrothermal method in combination with thermal treatment. The morphology, structure and composition were investigated by scanning electron microscopy, transmission electron microscopy, X-ray diffraction and X-ray photoelectron spectroscopy. As the electrode materials for supercapacitors, CuCo2O4 nanoneedles delivered the highest specific capacitance compared with other CuCo2O4 nanostructures. Electrochemical performance measurements demonstrate that the carbon layer can improve the electrochemical stability of CuCo2O4 nanoneedles. The CuCo2O4@C electrode exhibits a high specific capacitance of 1432.4 F g-1 at a current density of 1 A g-1, with capacitance retention of 98.2% after 3000 circles. These characteristics of CuCo2O4@C composite are mainly due to the unique one dimensional needle-liked architecture and the conducting carbon, which provide a faster ion/electron transfer rate. These excellent performances of the CuCo2O4@C electrode confirmed the material as a positive electrode for hybrid supercapacitor application.

  15. Hydatid Cyst of Tongue: A Diagnostic Challenge

    Directory of Open Access Journals (Sweden)

    Neeraj Aggarwal

    2017-12-01

    Full Text Available Introduction Hydatid disease or human cystic echinococcosis is a parasitic zoonosis, endemic in the cattle and dog rearing region worldwide as well as in some parts of India.Cystic echinococcosis affects mostly the liver and lung (80%, but tongue is one of the very rare sites. Case Report A 10 year old boy had presented with an isolated cystic lesion in tongue, which was expelled spontaneously with no residual lesion. On detailed examination, no other site in the body was involved. Discussion Parasitic cyst of the tongue is rare entity. Microbiological and histopathological examination helped clinch the diagnosis Hydatid cyst should be considered as a differential diagnosis in isolated cystic lesion of tongue, especially in the risk group.

  16. Compressibility Analysis of the Tongue During Speech

    National Research Council Canada - National Science Library

    Unay, Devrim

    2001-01-01

    .... In this paper, 3D compression and expansion analysis of the tongue will be presented. Patterns of expansion and compression have been compared for different syllables and various repetitions of each syllable...

  17. Huge Tongue Lipoma: A Case Report

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Damghani

    2015-03-01

    Full Text Available Introduction: Lipomas are among the most common tumors of the human body. However, they are uncommon in the oral cavity and are observed as slow growing, painless, and asymptomatic yellowish submucosal masses. Surgical excision is the treatment of choice and recurrence is not expected.    Case Report: The case of a 30-year-old woman with a huge lipoma on the tip of her tongue since 3 years, is presented. She had difficulty with speech and mastication because the tongue tumor was filling the oral cavity. Clinical examination revealed a yellowish lesion, measuring 8 cm in maximum diameter, protruding from the lingual surface. The tumor was surgically excised with restoration of normal tongue function and histopathological examination of the tumor confirmed that it was a lipoma.   Conclusion:  Tongue lipoma is rarely seen and can be a cause of macroglossia. Surgical excision for lipoma is indicated for symptomatic relief and exclusion of associated malignancy.

  18. Tongue schwannomas associated with neurofibromatosis type 2

    Directory of Open Access Journals (Sweden)

    Harusachi Kanazawa

    2018-06-01

    Full Text Available Schwannomas are typically solitary benign neural tumors; however, multiple lesions associated with the rare genetic disorder neurofibromatosis type 2 (NF2 have been reported in some cases. We present the case of a tongue schwannomas in a 36-year-old woman previously diagnosed with NF2 with bilateral vestibular schwannomas. To alleviate difficulties with swallowing, tongue nodular masses were surgically removed, and schwannoma was histologically diagnosed. Our patient represents the first case of histologically confirmed tongue schwannoma associated with NF2. This indicates that in patient with NF2, schwannoma may be detected in the oral cavity as well as in other parts of the body. Thus, careful clinical and histological examinations are warranted to identify schwannomas associated with NF2 even in the oral cavity. Keywords: Schwannoma, Tongue, Oral manifestation, Neurofibromatosis type 2 (NF2

  19. Resonance tongues in the linear Sitnikov equation

    Science.gov (United States)

    Misquero, Mauricio

    2018-04-01

    In this paper, we deal with a Hill's equation, depending on two parameters e\\in [0,1) and Λ >0, that has applications to some problems in Celestial Mechanics of the Sitnikov type. Due to the nonlinearity of the eccentricity parameter e and the coexistence problem, the stability diagram in the (e,Λ )-plane presents unusual resonance tongues emerging from points (0,(n/2)^2), n=1,2,\\ldots The tongues bounded by curves of eigenvalues corresponding to 2π -periodic solutions collapse into a single curve of coexistence (for which there exist two independent 2π -periodic eigenfunctions), whereas the remaining tongues have no pockets and are very thin. Unlike most of the literature related to resonance tongues and Sitnikov-type problems, the study of the tongues is made from a global point of view in the whole range of e\\in [0,1). Indeed, an interesting behavior of the tongues is found: almost all of them concentrate in a small Λ -interval [1, 9 / 8] as e→ 1^-. We apply the stability diagram of our equation to determine the regions for which the equilibrium of a Sitnikov (N+1)-body problem is stable in the sense of Lyapunov and the regions having symmetric periodic solutions with a given number of zeros. We also study the Lyapunov stability of the equilibrium in the center of mass of a curved Sitnikov problem.

  20. Tongue-controlled computer game: a new approach for rehabilitation of tongue motor function.

    Science.gov (United States)

    Kothari, Mohit; Svensson, Peter; Jensen, Jim; Holm, Trine Davidsen; Nielsen, Mathilde Skorstengaard; Mosegaard, Trine; Nielsen, Jørgen Feldbæk; Ghovanloo, Maysam; Baad-Hansen, Lene

    2014-03-01

    To investigate the influence of tongue disability, age, and sex on motor performance for a tongue-training paradigm involving playing a computer game using the Tongue Drive System (TDS). Two controlled observational studies. A neurorehabilitation center and a dental school. In study 1, tongue-disabled patients with symptoms of dysphagia and dysarthria (n=11) and age- and sex-matched controls (n=11) participated in tongue training. In study 2, healthy elderly persons (n=16) and healthy young persons (n=16) volunteered. In study 1 and study 2, the tongue training lasted 30 and 40 minutes, respectively. Participants were instructed to play a computer game with the tongue using TDS. Motor performance was compared between groups in both studies. Correlation analyses were performed between age and relative improvement in performance. Subject-based reports of motivation, fun, pain, and fatigue evaluated on 0-to-10 numeric rating scales were compared between groups. In study 1, tongue-disabled patients performed poorer than healthy controls (P=.005) and with a trend of a sex difference (P=.046). In study 2, healthy young participants performed better than healthy elderly participants (Peffect of sex (P=.140). There was a significant negative correlation between age and relative improvement in performance (δ=-.450; P=.009). There were no significant differences in subject-based reports of motivation, fun, pain, and fatigue between groups in any of the studies (P>.094). The present study provides evidence that tongue disability and age can influence behavioral measures of tongue motor performance. TDS may be a new adjunctive neurorehabilitation regimen in treating tongue-disabled patients. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  1. Voltammetry at micro-mesh electrodes

    Directory of Open Access Journals (Sweden)

    Wadhawan Jay D.

    2003-01-01

    Full Text Available The voltammetry at three micro-mesh electrodes is explored. It is found that at sufficiently short experimental durations, the micro-mesh working electrode first behaves as an ensemble of microband electrodes, then follows the behaviour anticipated for an array of diffusion-independent micro-ring electrodes of the same perimeter as individual grid-squares within the mesh. During prolonged electrolysis, the micro-mesh electrode follows that behaviour anticipated theoretically for a cubically-packed partially-blocked electrode. Application of the micro-mesh electrode for the electrochemical determination of carbon dioxide in DMSO electrolyte solutions is further illustrated.

  2. Detector array and method

    International Nuclear Information System (INIS)

    Timothy, J.G.; Bybee, R.L.

    1978-01-01

    A detector array and method are described in which sets of electrode elements are provided. Each set consists of a number of linear extending parallel electrodes. The sets of electrode elements are disposed at an angle (preferably orthogonal) with respect to one another so that the individual elements intersect and overlap individual elements of the other sets. Electrical insulation is provided between the overlapping elements. The detector array is exposed to a source of charged particles which in accordance with one embodiment comprise electrons derived from a microchannel array plate exposed to photons. Amplifier and discriminator means are provided for each individual electrode element. Detection means are provided to sense pulses on individual electrode elements in the sets, with coincidence of pulses on individual intersecting electrode elements being indicative of charged particle impact at the intersection of the elements. Electronic readout means provide an indication of coincident events and the location where the charged particle or particles impacted. Display means are provided for generating appropriate displays representative of the intensity and locaton of charged particles impacting on the detector array

  3. Standard values of maximum tongue pressure taken using newly developed disposable tongue pressure measurement device.

    Science.gov (United States)

    Utanohara, Yuri; Hayashi, Ryo; Yoshikawa, Mineka; Yoshida, Mitsuyoshi; Tsuga, Kazuhiro; Akagawa, Yasumasa

    2008-09-01

    It is clinically important to evaluate tongue function in terms of rehabilitation of swallowing and eating ability. We have developed a disposable tongue pressure measurement device designed for clinical use. In this study we used this device to determine standard values of maximum tongue pressure in adult Japanese. Eight hundred fifty-three subjects (408 male, 445 female; 20-79 years) were selected for this study. All participants had no history of dysphagia and maintained occlusal contact in the premolar and molar regions with their own teeth. A balloon-type disposable oral probe was used to measure tongue pressure by asking subjects to compress it onto the palate for 7 s with maximum voluntary effort. Values were recorded three times for each subject, and the mean values were defined as maximum tongue pressure. Although maximum tongue pressure was higher for males than for females in the 20-49-year age groups, there was no significant difference between males and females in the 50-79-year age groups. The maximum tongue pressure of the seventies age group was significantly lower than that of the twenties to fifties age groups. It may be concluded that maximum tongue pressures were reduced with primary aging. Males may become weaker with age at a faster rate than females; however, further decreases in strength were in parallel for male and female subjects.

  4. Microfabricated Multianalyte Sensor Arrays for Metabolic Monitoring

    National Research Council Canada - National Science Library

    Pishko, Michael V

    2006-01-01

    ...(ethylene glycol) diacrylate or PEG-DA on the array electrodes. The fabricated microarray sensors were individually addressable and with no cross-talk between adjacent array elements as assessed using cyclic voltammetry...

  5. Microfabricated Multianalyte Sensor Arrays for Metabolic Monitoring

    National Research Council Canada - National Science Library

    Pishko, Michael V

    2007-01-01

    ...(ethylene glycol) diacrylate or PEG-DA on the array electrodes. The fabricated microarray sensors were individually addressable and with no cross-talk between adjacent array elements as assessed using cyclic voltammetry...

  6. Construct hierarchical electrode with NixCo3-xS4 nanosheet coated on NiCo2O4 nanowire arrays grown on carbon fiber paper for high-performance asymmetric supercapacitors

    Science.gov (United States)

    Cao, Liujun; Tang, Gang; Mei, Jun; Liu, Hao

    2017-08-01

    In order to boost the energy density of supercapacitors, the strategy of using advanced pseudo-capacitive electrode and asymmetric device architecture is feasible and effective. Herein, we report a significant advance in the design and synthesis of a new hierarchically nanostructures with a series of controllable Ni/Co molar ratios of NixCo3-xS4 (i.e., NiCo2S4 and Ni2CoS4) nanosheets coatings have in situ grown on NiCo2O4 nanowires arrays on a flexible carbon fiber paper (CFP). Remarkably, the hybrid Ni2CoS4@NiCo2O4 composite electrode delivers the highest discharge gravimetric capacitance of 1501 F g-1, and areal capacitance of 1.86 F cm-2 at 1 mA cm-2. Furthermore, coupled with nitrogen-doped carbon xerogels anode, we have fabricated a 1.6 V asymmetric supercapacitor (Ni2CoS4@NiCo2O4//nitrogen-doped carbon xerogels), such device delivers a maximum energy and power densities of 32.2 Wh kg-1 and 2.5 kW kg-1 in 1.0 M KOH electrolyte, respectively, and an excellent cycling stability (∼87.6% retention after 10,000 cycles).

  7. Electronic tongue: An analytical gustatory tool

    Directory of Open Access Journals (Sweden)

    Rewanthwar Swathi Latha

    2012-01-01

    Full Text Available Taste is an important organoleptic property governing acceptance of products for administration through mouth. But majority of drugs available are bitter in taste. For patient acceptability and compliance, bitter taste drugs are masked by adding several flavoring agents. Thus, taste assessment is one important quality control parameter for evaluating taste-masked formulations. The primary method for the taste measurement of drug substances and formulations is by human panelists. The use of sensory panelists is very difficult and problematic in industry and this is due to the potential toxicity of drugs and subjectivity of taste panelists, problems in recruiting taste panelists, motivation and panel maintenance are significantly difficult when working with unpleasant products. Furthermore, Food and Drug Administration (FDA-unapproved molecules cannot be tested. Therefore, analytical taste-sensing multichannel sensory system called as electronic tongue (e-tongue or artificial tongue which can assess taste have been replacing the sensory panelists. Thus, e-tongue includes benefits like reducing reliance on human panel. The present review focuses on the electrochemical concepts in instrumentation, performance qualification of E-tongue, and applications in various fields.

  8. A Hybrid System Based on an Electronic Nose Coupled with an Electronic Tongue for the Characterization of Moroccan Waters

    Directory of Open Access Journals (Sweden)

    Z. Haddi

    2014-05-01

    Full Text Available A hybrid multisensor system combined with multivariate analysis was applied to the characterization of different kinds of Moroccan waters. The proposed hybrid system based on an electronic nose coupled with an electronic tongue consisted of metal oxide semiconductors and potentiometric sensors respectively. Five Taguchi Gas Sensors were implemented in the electronic nose for the discrimination between mineral, natural, sparkling, river and tap waters. Afterwards, the electronic tongue, based on series of Ion-Selective-Electrodes was applied to the analysis of the same waters. Multisensor responses obtained from the waters were processed by two chemometrics: Principal Component Analysis (PCA and Linear Discriminant Analysis (LDA. PCA results using electronic nose data depict all of the potable water samples in a separate group from the samples that were originated from river. Furthermore, PCA and LDA analysis on electronic tongue data permitted clear and rapid recognizing of the different waters due to the concentration changes of the chemical parameters from source to another.

  9. Three-dimensional tori and Arnold tongues

    Energy Technology Data Exchange (ETDEWEB)

    Sekikawa, Munehisa, E-mail: sekikawa@cc.utsunomiya-u.ac.jp [Department of Mechanical and Intelligent Engineering, Utsunomiya University, Utsunomiya-shi 321-8585 (Japan); Inaba, Naohiko [Organization for the Strategic Coordination of Research and Intellectual Property, Meiji University, Kawasaki-shi 214-8571 (Japan); Kamiyama, Kyohei [Department of Electronics and Bioinformatics, Meiji University, Kawasaki-shi 214-8571 (Japan); Aihara, Kazuyuki [Institute of Industrial Science, the University of Tokyo, Meguro-ku 153-8505 (Japan)

    2014-03-15

    This study analyzes an Arnold resonance web, which includes complicated quasi-periodic bifurcations, by conducting a Lyapunov analysis for a coupled delayed logistic map. The map can exhibit a two-dimensional invariant torus (IT), which corresponds to a three-dimensional torus in vector fields. Numerous one-dimensional invariant closed curves (ICCs), which correspond to two-dimensional tori in vector fields, exist in a very complicated but reasonable manner inside an IT-generating region. Periodic solutions emerge at the intersections of two different thin ICC-generating regions, which we call ICC-Arnold tongues, because all three independent-frequency components of the IT become rational at the intersections. Additionally, we observe a significant bifurcation structure where conventional Arnold tongues transit to ICC-Arnold tongues through a Neimark-Sacker bifurcation in the neighborhood of a quasi-periodic Hopf bifurcation (or a quasi-periodic Neimark-Sacker bifurcation) boundary.

  10. Convergence of macroscopic tongue anatomy in ruminants and scaling relationships with body mass or tongue length.

    Science.gov (United States)

    Meier, Andrea R; Schmuck, Ute; Meloro, Carlo; Clauss, Marcus; Hofmann, Reinhold R

    2016-03-01

    Various morphological measures demonstrate convergent evolution in ruminants with their natural diet, in particular with respect to the browser/grazer dichotomy. Here, we report quantitative macroanatomical measures of the tongue (length and width of specific parts) of 65 ruminant species and relate them to either body mass (BM) or total tongue length, and to the percentage of grass in the natural diet (%grass). Models without and with accounting for the phylogenetic structures of the dataset were used, and models were ranked using Akaike's Information Criterion. Scaling relationships followed geometric principles, that is, length measures scaled with BM to the power of 0.33. Models that used tongue length rather than BM as a body size proxy were consistently ranked better, indicating that using size proxies that are less susceptible to a wider variety of factors (such as BM that fluctuates with body condition) should be attempted whenever possible. The proportion of the freely mobile tongue tip of the total tongue (and hence also the corpus length) was negatively correlated to %grass, in accordance with concepts that the feeding mechanism of browsers requires more mobile tongues. It should be noted that some nonbrowsers, such as cattle, use a peculiar mechanism for grazing that also requires long, mobile tongues, but they appear to be exceptions. A larger corpus width with increasing %grass corresponds to differences in snout shape with broader snouts in grazers. The Torus linguae is longer with increasing %grass, a finding that still warrants functional interpretation. This study shows that tongue measures covary with diet in ruminants. In contrast, the shape of the tongue (straight or "hourglass-shaped" as measured by the ratio of the widest and smallest corpus width) is unrelated to diet and is influenced strongly by phylogeny. © 2015 Wiley Periodicals, Inc.

  11. Repeated tongue lift movement induces neuroplasticity in corticomotor control of tongue and jaw muscles in humans.

    Science.gov (United States)

    Komoda, Yoshihiro; Iida, Takashi; Kothari, Mohit; Komiyama, Osamu; Baad-Hansen, Lene; Kawara, Misao; Sessle, Barry; Svensson, Peter

    2015-11-19

    This study investigated the effect of repeated tongue lift training (TLT) on the excitability of the corticomotor representation of the human tongue and jaw musculature. Sixteen participants performed three series of TLT for 41 min on each of 5 consecutive days. Each TLT series consisted of two pressure levels (5 kPa and 10 kPa). All participants underwent transcranial magnetic stimulation (TMS) and electromyographic (EMG) recordings of motor evoked potentials (MEPs) in four sessions: (1) before TLT on Day 1 (baseline), (2) after TLT on Day 1, (3) before TLT on Day 5, and (4) after TLT on Day 5. EMG recordings from the left and right tongue dorsum and masseter muscles were made at three pressure levels (5 kPa, 10 kPa, 100% tongue lift), and tongue, masseter, and first dorsal interosseous (FDI) MEPs were measured. There were no significant day-to-day differences in the tongue pressure during maximum voluntary contractions. The amplitudes and thresholds of tongue and masseter MEPs after TLT on Day 5 were respectively higher and lower than before TLT on Day 1 (P<0.005), and there was also a significant increase in tongue and masseter MEP areas; no significant changes occurred in MEP onset latencies. FDI MEP parameters (amplitude, threshold, area, latency) were not significantly different between the four sessions. Our findings suggest that repeated TLT can trigger neuroplasticity reflected in increased excitability of the corticomotor representation of not only the tongue muscles but also the masseter muscles. Copyright © 2015. Published by Elsevier B.V.

  12. Specialized bat tongue is a hemodynamic nectar mop

    OpenAIRE

    Harper, Cally J.; Swartz, Sharon M.; Brainerd, Elizabeth L.

    2013-01-01

    Nectarivorous birds and bats have evolved highly specialized tongues to gather nectar from flowers. Here, we show that a nectar-feeding bat, Glossophaga soricina, uses dynamic erectile papillae to collect nectar. In G. soricina, the tip of the tongue is covered with long filamentous papillae and resembles a brush or mop. During nectar feeding, blood vessels within the tongue tip become engorged with blood and the papillae become erect. Tumescence and papilla erection persist throughout tongue...

  13. Vertically oriented CoO@FeOOH nanowire arrays anchored on carbon cloth as a highly efficient electrode for oxygen evolution reaction

    International Nuclear Information System (INIS)

    Wang, Yin; Ni, Yuanman; Liu, Bing; Shang, Shuxia; Yang, Song; Cao, Minhua; Hu, Changwen

    2017-01-01

    Graphical abstract: Three-dimensional CoO@FeOOH nanowire arrays grown on carbon cloth were constructed, which exhibit good electrocatalytic activity towards OER in alkaline solution. Display Omitted -- Abstract: Developing high efficiency electrocatalysts for electrocatalytic oxygen evolution reaction (OER) is a key to water splitting. In this work, we demonstrate the preparation of CoO@FeOOH core-shell nanowire (NWs) grown on three-dimensional (3D) carbon cloth (CC@CoO@FeOOH-NWAs) by hydrothermal method followed by electrodeposition process as well as its highly efficient activity for water oxidation. In this hybrid structure, CoO@FeOOH-NWs with an average diameter of 100 nm is vertically grown on the surface of carbon fibers of the carbon cloth. The combination of CoO@FeOOH catalyst with good electron transfer substrate exhibits exceptionally good electrocatalytic activity and long-term durability towards oxygen evolution reaction in alkaline solution. It needs an overpotential as low as 255 mV to achieve the current density of 10 mA cm −2 , with a Tafel slope of 82 mV dec −1 and also exhibits a good stability in 20 h. In addition, the nanowire array structure is well retained after the durability test with high current density of 50 mA cm −2 . Our strategy provides a guide to rational design of micro-structures of the materials to achieve their high performance.

  14. Implementation of the Mother-Tongue/Language Component of the ...

    African Journals Online (AJOL)

    Implementation of the Mother-Tongue/Language Component of the National Policy on Education In Nigeria. ... Lwati: A Journal of Contemporary Research ... the implementation of the mother-tongue/language policy; curriculum materials were not supplied in schools for mother-tongue instruction; specialized teachers were ...

  15. Evidence for an elastic projection mechanism in the chameleon tongue

    NARCIS (Netherlands)

    Groot, de J.H.; Leeuwen, van J.L.

    2004-01-01

    To capture prey, chameleons ballistically project their tongues as far as 1.5 body lengths with accelerations of up to 500 m s-2. At the core of a chameleon's tongue is a cylindrical tongue skeleton surrounded by the accelerator muscle. Previously, the cylindrical accelerator muscle was assumed to

  16. Perceived Intensity and Discrimination Ability for Lingual Electrotactile Stimulation Depends on Location and Orientation of Electrodes

    Directory of Open Access Journals (Sweden)

    Leslie M. Stone-Roy

    2017-04-01

    Full Text Available Malfunctioning sensory systems can severely impact quality of life and repair is not always possible. One solution, called sensory substitution, is to use another sensory system to bring lost information to the brain. This approach often involves the use of bioengineered devices that electrically stimulate somatosensory fibers. Interestingly, the tongue is an ideal location for electrotactile stimulation due to its dense innervation, moisture, and protected environment. Success with transmitting visual and vestibular information through the tongue indicates promise for future applications. However, sensitivity and discrimination ability varies between individuals and across the tongue surface complicating efforts to produce reliable and consistent sensations. The goals of the present study were to investigate these differences more precisely to better understand the mechanosensory innervation of the tongue so that future electrotactile devices can be designed more effectively. Specifically, we tested whether stimulation of certain regions of the tongue consistently result in better perception, whether the spacing of stimulating electrodes affects perceived intensity, and whether the orientation of electrodes affects perceived intensity and discrimination. To test these hypotheses, we built a custom tongue stimulation device, recruited 25 participants, and collected perceived intensity and discrimination data. We then subjected the data to thorough statistical analyses. Consistent with previous studies, we found that stimulation of the anterior medial tongue region was perceived as more intense than stimulation of lateral and posterior regions. This region also had the best discrimination ability for electrodes. Dividing the stimulated tongue area into 16 distinct regions allowed us to compare perception ability between anterior and posterior regions, medial and lateral regions, and the left and right sides of the tongue. Stimulation of the most

  17. Statistical generation of training sets for measuring NO3(-), NH4(+) and major ions in natural waters using an ion selective electrode array.

    Science.gov (United States)

    Mueller, Amy V; Hemond, Harold F

    2016-05-18

    Knowledge of ionic concentrations in natural waters is essential to understand watershed processes. Inorganic nitrogen, in the form of nitrate and ammonium ions, is a key nutrient as well as a participant in redox, acid-base, and photochemical processes of natural waters, leading to spatiotemporal patterns of ion concentrations at scales as small as meters or hours. Current options for measurement in situ are costly, relying primarily on instruments adapted from laboratory methods (e.g., colorimetric, UV absorption); free-standing and inexpensive ISE sensors for NO3(-) and NH4(+) could be attractive alternatives if interferences from other constituents were overcome. Multi-sensor arrays, coupled with appropriate non-linear signal processing, offer promise in this capacity but have not yet successfully achieved signal separation for NO3(-) and NH4(+)in situ at naturally occurring levels in unprocessed water samples. A novel signal processor, underpinned by an appropriate sensor array, is proposed that overcomes previous limitations by explicitly integrating basic chemical constraints (e.g., charge balance). This work further presents a rationalized process for the development of such in situ instrumentation for NO3(-) and NH4(+), including a statistical-modeling strategy for instrument design, training/calibration, and validation. Statistical analysis reveals that historical concentrations of major ionic constituents in natural waters across New England strongly covary and are multi-modal. This informs the design of a statistically appropriate training set, suggesting that the strong covariance of constituents across environmental samples can be exploited through appropriate signal processing mechanisms to further improve estimates of minor constituents. Two artificial neural network architectures, one expanded to incorporate knowledge of basic chemical constraints, were tested to process outputs of a multi-sensor array, trained using datasets of varying degrees of

  18. Integrated, paper-based potentiometric electronic tongue for the analysis of beer and wine.

    Science.gov (United States)

    Nery, Emilia Witkowska; Kubota, Lauro T

    2016-04-28

    The following manuscript details the stages of construction of a novel paper-based electronic tongue with an integrated Ag/AgCl reference, which can operate using a minimal amount of sample (40 μL). First, we optimized the fabrication procedure of silver electrodes, testing a set of different methodologies (electroless plating, use of silver nanoparticles and commercial silver paints). Later a novel, integrated electronic tongue system was assembled with the use of readily available materials such as paper, wax, lamination sheets, bleach etc. New system was thoroughly characterized and the ion-selective potentiometric sensors presented performance close to theoretical. An electronic tongue, composed of electrodes sensitive to sodium, calcium, ammonia and a cross-sensitive, anion-selective electrode was used to analyze 34 beer samples (12 types, 19 brands). This system was able to discriminate beers from different brands, and types, indicate presence of stabilizers and antioxidants, dyes or even unmalted cereals and carbohydrates added to the fermentation wort. Samples could be classified by type of fermentation (low, high) and system was able to predict pH and in part also alcohol content of tested beers. In the next step sample volume was minimalized by the use of paper sample pads and measurement in flow conditions. In order to test the impact of this advancement a four electrode system, with cross-sensitive (anion-selective, cation-selective, Ca(2+)/Mg(2+), K(+)/Na(+)) electrodes was applied for the analysis of 11 types of wine (4 types of grapes, red/white, 3 countries). Proposed matrix was able to group wines produced from different varieties of grapes (Chardonnay, Americanas, Malbec, Merlot) using only 40 μL of sample. Apart from that, storage stability studies were performed using a multimeter, therefore showing that not only fabrication but also detection can be accomplished by means of off-the-shelf components. This manuscript not only describes new

  19. Tongue Scrapers Only Slightly Reduce Bad Breath

    Science.gov (United States)

    ... for eliminating malodor. The authors of the General Dentistry article feel that future research is necessary to determine what role undetected odorants may play in oral malodor, as well as more well designed, randomized clinical trials to compare the effectiveness of tongue scrapers, ...

  20. Does Barium Influence Tongue Behaviors during Swallowing?

    Science.gov (United States)

    Steele, Catriona M.; van Lieshout, Pascal H. H. M.

    2005-01-01

    The validity of videofluoroscopic swallowing assessments rests on the understanding that thin, nectar-, honey-, and spoon-thick radiopaque liquids resemble nonopaque liquids, both in their consistency and in the variations in swallowing that they elicit. Tongue movements during sequential swallows of opaque and nonopaque liquids were studied in 8…

  1. A 3-Dimensional Atlas of Human Tongue Muscles

    Science.gov (United States)

    SANDERS, IRA; MU, LIANCAI

    2013-01-01

    The human tongue is one of the most important yet least understood structures of the body. One reason for the relative lack of research on the human tongue is its complex anatomy. This is a real barrier to investigators as there are few anatomical resources in the literature that show this complex anatomy clearly. As a result, the diagnosis and treatment of tongue disorders lags behind that for other structures of the head and neck. This report intended to fill this gap by displaying the tongue’s anatomy in multiple ways. The primary material used in this study was serial axial images of the male and female human tongue from the Visible Human (VH) Project of the National Library of Medicine. In addition, thick serial coronal sections of three human tongues were rendered translucent. The VH axial images were computer reconstructed into serial coronal sections and each tongue muscle was outlined. These outlines were used to construct a 3-dimensional computer model of the tongue that allows each muscle to be seen in its in vivo anatomical position. The thick coronal sections supplement the 3-D model by showing details of the complex interweaving of tongue muscles throughout the tongue. The graphics are perhaps the clearest guide to date to aid clinical or basic science investigators in identifying each tongue muscle in any part of the human tongue. PMID:23650264

  2. Piezoelectric transducer array microspeaker

    KAUST Repository

    Carreno, Armando Arpys Arevalo; Conchouso Gonzalez, David; Castro, David; Kosel, Jü rgen; Foulds, Ian G.

    2016-01-01

    contains 2n piezoelectric transducer membranes, where “n” is the bit number. Every element of the array has a circular shape structure. The membrane is made out four layers: 300nm of platinum for the bottom electrode, 250nm or lead zirconate titanate (PZT

  3. Architecturing hierarchical function layers on self-assembled viral templates as 3D nano-array electrodes for integrated Li-ion microbatteries.

    Science.gov (United States)

    Liu, Yihang; Zhang, Wei; Zhu, Yujie; Luo, Yanting; Xu, Yunhua; Brown, Adam; Culver, James N; Lundgren, Cynthia A; Xu, Kang; Wang, Yuan; Wang, Chunsheng

    2013-01-09

    This work enables an elegant bottom-up solution to engineer 3D microbattery arrays as integral power sources for microelectronics. Thus, multilayers of functional materials were hierarchically architectured over tobacco mosaic virus (TMV) templates that were genetically modified to self-assemble in a vertical manner on current-collectors, so that optimum power and energy densities accompanied with excellent cycle-life could be achieved on a minimum footprint. The resultant microbattery based on self-aligned LiFePO(4) nanoforests of shell-core-shell structure, with precise arrangement of various auxiliary material layers including a central nanometric metal core as direct electronic pathway to current collector, delivers excellent energy density and stable cycling stability only rivaled by the best Li-ion batteries of conventional configurations, while providing rate performance per foot-print and on-site manufacturability unavailable from the latter. This approach could open a new avenue for microelectromechanical systems (MEMS) applications, which would significantly benefit from the concept that electrochemically active components be directly engineered and fabricated as an integral part of the integrated circuit (IC).

  4. Spray layer-by-layer films based on phospholipid vesicles aiming sensing application via e-tongue system

    International Nuclear Information System (INIS)

    Aoki, P.H.B.; Volpati, D.; Cabrera, F.C.; Trombini, V.L.; Riul, A.; Constantino, C.J.L.

    2012-01-01

    dipping- and spray-LbL techniques and also by Langmuir–Blodgett (LB) onto Pt interdigitated electrodes composing an array of sensing units (e-tongue) were applied in the detection of a xanthene derivate (eosin) in diluted solutions (10 −9 , 10 −7 and 10 −6 M). Despite the LB and LbL films are formed by the same materials (PAH and DPPG), it was found that their different molecular architectures play an important role on the electrical response of Pt interdigitated electrodes in impedance spectroscopy measurements. The high sensitivity reached by these sensing units was intimately related to changes in the film morphology caused by the adsorption of the eosin molecules onto the film surfaces during electrical measurements, as evidenced by micro-Raman technique. - Highlights: ► DPPG phospholipid vesicles were immobilized alternately with PAH through spray-LbL technique. ► DPPG is kept in the form of vesicles despite the pressure applied during spray deposition. ► Spray-LbL films of PAH/DPPG composed an array of sensors applied in e-tongue experiments. ► High diluted solutions of xanthene compound were detected.

  5. Biomolecular Markers in Cancer of the Tongue

    Directory of Open Access Journals (Sweden)

    Daris Ferrari

    2009-01-01

    Full Text Available The incidence of tongue cancer is increasing worldwide, and its aggressiveness remains high regardless of treatment. Genetic changes and the expression of abnormal proteins have been frequently reported in the case of head and neck cancers, but the little information that has been published concerning tongue tumours is often contradictory. This review will concentrate on the immunohistochemical expression of biomolecular markers and their relationships with clinical behaviour and prognosis. Most of these proteins are associated with nodal stage, tumour progression and metastases, but there is still controversy concerning their impact on disease-free and overall survival, and treatment response. More extensive clinical studies are needed to identify the patterns of molecular alterations and the most reliable predictors in order to develop tailored anti-tumour strategies based on the targeting of hypoxia markers, vascular and lymphangiogenic factors, epidermal growth factor receptors, intracytoplasmatic signalling and apoptosis.

  6. Proposal for a New Noncontact Method for Measuring Tongue Moisture to Assist in Tongue Diagnosis and Development of the Tongue Image Analyzing System, Which Can Separately Record the Gloss Components of the Tongue

    Directory of Open Access Journals (Sweden)

    Toshiya Nakaguchi

    2015-01-01

    Full Text Available Tongue diagnosis is a noninvasive diagnosis and is traditionally one of the most important tools for physicians who practice Kampo (traditional Japanese medicine. However, it is a subjective process, and its results can depend on the experience of the physician performing it. Previous studies have reported how to measure and evaluate the shape and color of the tongue objectively. Therefore, this study focused on the glossy component in order to quantify tongue moisture in tongue diagnosis. We hypothesized that moisture appears as a gloss in captured images and measured the amount of water on the tongue surface in 13 subjects. The results showed a high correlation between the degree of gloss and the amount of water on the tongue surface and suggested that the moisture on the tongue can be estimated by the degree of gloss in a captured image. Because the moisture level on the tongue changes during the course of taking photos, it became clear that we had to wait at least 3 minutes between photos. Based on these results, we established the tongue image analyzing system (TIAS, which can consistently record the gloss and color of the tongue surface simultaneously.

  7. Proposal for a new noncontact method for measuring tongue moisture to assist in tongue diagnosis and development of the tongue image analyzing system, which can separately record the gloss components of the tongue.

    Science.gov (United States)

    Nakaguchi, Toshiya; Takeda, Kanako; Ishikawa, Yuya; Oji, Takeshi; Yamamoto, Satoshi; Tsumura, Norimichi; Ueda, Keigo; Nagamine, Koichi; Namiki, Takao; Miyake, Yoichi

    2015-01-01

    Tongue diagnosis is a noninvasive diagnosis and is traditionally one of the most important tools for physicians who practice Kampo (traditional Japanese) medicine. However, it is a subjective process, and its results can depend on the experience of the physician performing it. Previous studies have reported how to measure and evaluate the shape and color of the tongue objectively. Therefore, this study focused on the glossy component in order to quantify tongue moisture in tongue diagnosis. We hypothesized that moisture appears as a gloss in captured images and measured the amount of water on the tongue surface in 13 subjects. The results showed a high correlation between the degree of gloss and the amount of water on the tongue surface and suggested that the moisture on the tongue can be estimated by the degree of gloss in a captured image. Because the moisture level on the tongue changes during the course of taking photos, it became clear that we had to wait at least 3 minutes between photos. Based on these results, we established the tongue image analyzing system (TIAS), which can consistently record the gloss and color of the tongue surface simultaneously.

  8. Base of Tongue Tuberculosis: A Case Report

    Directory of Open Access Journals (Sweden)

    Carlos Chiesa Estomba

    2015-05-01

    Full Text Available Introduction: Tuberculosis is an infectious disease that has displayed increasing incidence in the last decades. It is estimated that up to 20% of tuberculosis cases affect extra-pulmonary organs. In the ENT area, soft palate and tongue are the least probable locations.   Case Report A 62-year-old female with a history of rheumatoid arthritis and treatment with corticosteroids and Adalimumab, developed a foreign body sensation in the pharynx accompanied by a sore throat and halitosis. The laryngoscopy with a 70 degree rigid telescope showed an ulcerated hypertrophic lesion in the right vallecula of about 2-3 cm in the base of the tongue. Acid-alcohol resistant bacilli were found positive for M. tuberculosis, through the Ziehl Neelsen method and Löwenstein culture the patient was treated with tuberculostatic medication. Conclusion:  TB is a possible diagnosis when in the presence of an ulcerated lesion at the base of the tongue, accompanied by sore throat, dysphagia, or foreign body sensation.

  9. Effect of electrode shape on grounding resistances - Part 1

    DEFF Research Database (Denmark)

    Ingeman-Nielsen, Thomas; Tomaskovicova, Sonia; Dahlin, Torleif

    2016-01-01

    Electrode grounding resistance is a major factor affecting measurement quality in electric resistivity tomography (ERT) measurements for cryospheric applications. Still, little information is available on grounding resistances in the geophysical literature, mainly because it is difficult to measure....... The focus-one protocol is a new method for estimating single electrode grounding resistances by measuring the resistance between a single electrode in an ERT array and all the remaining electrodes connected in parallel. For large arrays, the measured resistance is dominated by the grounding resistance...... of the electrode under test, the focus electrode. We have developed an equivalent circuit model formulation for the resistance measured when applying the focus-one protocol. Our model depends on the individual grounding resistances of the electrodes of the array, the mutual resistances between electrodes...

  10. Effectiveness of a new toothbrush design versus a conventional tongue scraper in improving breath odor and reducing tongue microbiota

    Directory of Open Access Journals (Sweden)

    Luciana Assirati Casemiro

    2008-08-01

    Full Text Available For centuries, specific instruments or regular toothbrushes have routinely been used to remove tongue biofilm and improve breath odor. Toothbrushes with a tongue scraper on the back of their head have recently been introduced to the market. The present study compared the effectiveness of a manual toothbrush with this new design, i.e., possessing a tongue scraper, and a commercial tongue scraper in improving breath odor and reducing the aerobic and anaerobic microbiota of tongue surface. The evaluations occurred at 4 moments, when the participants (n=30 had their halitosis quantified with a halimeter and scored according to a 4-point scoring system corresponding to different levels of intensity. Saliva was collected for counts of aerobic and anaerobic microorganisms. Data were analyzed statistically by Friedman's test (p<0.05. When differences were detected, the Wilcoxon test adjusted for Bonferroni correction was used for multiple comparisons (group to group. The results confirmed the importance of mechanical cleaning of the tongue, since this procedure provided an improvement in halitosis and reduction of aerobe and anaerobe counts. Regarding the evaluated methods, the toothbrush's tongue scraper and conventional tongue scraper had a similar performance in terms of breath improvement and reduction of tongue microbiota, and may be indicated as effective methods for tongue cleaning.

  11. Enterobacteriaceae and pseudomonadaceae on the dorsum of the human tongue

    Directory of Open Access Journals (Sweden)

    Simone Conti

    2009-10-01

    Full Text Available OBJECTIVE: The aim of this study was to correlate the presence of Enterobacteriaceae, Pseudomonadaceae, Moraxellaceae and Xanthomonadaceae on the posterior dorsum of the human tongue with the presence of tongue coating, gender, age, smoking habit and denture use. MATERIAL AND METHODS: Bacteria were isolated from the posterior tongue dorsum of 100 individuals in MacConkey agar medium and were identified by the API 20E system (Biolab-Mérieux. RESULTS: 43% of the individuals, presented the target microorganisms on the tongue dorsum, with greater prevalence among individuals between 40 and 50 years of age (p = 0.001 and non-smokers (p=0.0485. CONCLUSIONS: A higher prevalence of Enterobacteriaceae and Pseudomonadaceae was observed on the tongue dorsum of the individuals evaluated. There was no correlation between these species and the presence and thickness of tongue coating, gender and presence of dentures.

  12. Influence of visual observational conditions on tongue motor learning

    DEFF Research Database (Denmark)

    Kothari, Mohit; Liu, Xuimei; Baad-Hansen, Lene

    2016-01-01

    To investigate the impact of visual observational conditions on performance during a standardized tongue-protrusion training (TPT) task and to evaluate subject-based reports of helpfulness, disturbance, pain, and fatigue due to the observational conditions on 0-10 numerical rating scales. Forty...... regarding the level of disturbance, pain or fatigue. Self-observation of tongue-training facilitated behavioral aspects of tongue motor learning compared with model-observation but not compared with control....

  13. Digital electrostatic acoustic transducer array

    KAUST Repository

    Carreno, Armando Arpys Arevalo

    2016-12-19

    In this paper we present the fabrication and characterization of an array of electrostatic acoustic transducers. The array is micromachined on a silicon wafer using standard micro-machining techniques. Each array contains 2n electrostatic transducer membranes, where “n” is the bit number. Every element of the array has a hexagonal membrane shape structure, which is separated from the substrate by 3µm air gap. The membrane is made out 5µm thick polyimide layer that has a bottom gold electrode on the substrate and a gold top electrode on top of the membrane (250nm). The wafer layout design was diced in nine chips with different array configurations, with variation of the membrane dimensions. The device was tested with 90 V giving and sound output level as high as 35dB, while actuating all the elements at the same time.

  14. Digital electrostatic acoustic transducer array

    KAUST Repository

    Carreno, Armando Arpys Arevalo; Castro, David; Conchouso Gonzalez, David; Kosel, Jü rgen; Foulds, Ian G.

    2016-01-01

    In this paper we present the fabrication and characterization of an array of electrostatic acoustic transducers. The array is micromachined on a silicon wafer using standard micro-machining techniques. Each array contains 2n electrostatic transducer membranes, where “n” is the bit number. Every element of the array has a hexagonal membrane shape structure, which is separated from the substrate by 3µm air gap. The membrane is made out 5µm thick polyimide layer that has a bottom gold electrode on the substrate and a gold top electrode on top of the membrane (250nm). The wafer layout design was diced in nine chips with different array configurations, with variation of the membrane dimensions. The device was tested with 90 V giving and sound output level as high as 35dB, while actuating all the elements at the same time.

  15. Training induced cortical plasticity compared between three tongue training paradigms

    DEFF Research Database (Denmark)

    Kothari, Mohit; Svensson, Peter; Jensen, Jim

    2013-01-01

    The primary aim of this study was to investigate the effect of different training types and secondary to test gender differences on the training-related cortical plasticity induced by three different tongue training paradigms: 1. Therapeutic tongue exercises (TTE), 2. Playing computer games......) (control) were established using transcranial magnetic stimulation (TMS) at three time-points: (1) before tongue training, (2) immediately after training, (3) 1 h after training. Subject-based reports of motivation, fun, pain and fatigue were evaluated on 0-10 numerical rating scales (NRS) after training....... The resting motor thresholds of tongue MEPs were lowered by training with TDS and TPT (Ptraining with TDS and TPT (P

  16. Characterisation of nano-interdigitated electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Skjolding, L H D; Ribayrol, A; Montelius, L [Division of Solid State Physics, Lund University, Box 118, SE-221 00 Lund (Sweden); Spegel, C [Department of Analytical Chemistry Lund University, Box 124, SE-221 00 Lund (Sweden); Emneus, J [MIC - Department of Micro and Nanotechnology, DTU - Building 345 East, DK-2800 Kgs. Lyngby (Denmark)], E-mail: lars_henrik.daehli_skjolding@ftf.lth.se

    2008-03-15

    Interdigitated electrodes made up of two individually addressable interdigitated comb-like electrode structures have frequently been suggested as ultra sensitive electrochemical biosensors. Since the signal enhancement effects due to cycling of the reduced and oxidized species are strongly dependent on the inter electrode distances, since the nature of the enhancement is due to overlying diffusion layers, interdigitated electrodes with an electrode separation of less then one micrometer are desired for maximum signal amplification. Fabrication of submicron structures can only be made by advanced lithography techniques. By use of electron beam lithography we have fabricated arrays of interdigitated electrodes with an electrode separation distance of 200 nm and an electrode finger width of likewise 200 nm. The entire electrode structure is 100 micrometre times 100 micrometre, and the active electrode area is dictated by the opening in the passivation layer, that is defined by UV lithography. Here we report measurements of redox cycling of ferrocyanide by coupled cyclic voltammograms, where the potential at one of the working electrodes are varied and either an oxidising or reducing potential is applied to the complimentary interdigitated electrode. The measurements show fast conversion and high collection efficiency round 87% as expected for nano-interdigitated electrodes.

  17. Oriented nanotube electrodes for lithium ion batteries and supercapacitors

    Science.gov (United States)

    Frank, Arthur J.; Zhu, Kai; Wang, Qing

    2013-03-05

    An electrode having an oriented array of multiple nanotubes is disclosed. Individual nanotubes have a lengthwise inner pore defined by interior tube walls which extends at least partially through the length of the nanotube. The nanotubes of the array may be oriented according to any identifiable pattern. Also disclosed is a device featuring an electrode and methods of fabrication.

  18. Liquid electrode

    Science.gov (United States)

    Ekechukwu, A.A.

    1994-07-05

    A dropping electrolyte electrode is described for use in electrochemical analysis of non-polar sample solutions, such as benzene or cyclohexane. The liquid electrode, preferably an aqueous salt solution immiscible in the sample solution, is introduced into the solution in dropwise fashion from a capillary. The electrolyte is introduced at a known rate, thus, the droplets each have the same volume and surface area. The electrode is used in making standard electrochemical measurements in order to determine properties of non-polar sample solutions. 2 figures.

  19. Cat Got Your Tongue? Using the Tip-of-the-Tongue State to Investigate Fixed Expressions

    Science.gov (United States)

    Nordmann, Emily; Cleland, Alexandra A.; Bull, Rebecca

    2013-01-01

    Despite the fact that they play a prominent role in everyday speech, the representation and processing of fixed expressions during language production is poorly understood. Here, we report a study investigating the processes underlying fixed expression production. "Tip-of-the-tongue" (TOT) states were elicited for well-known idioms…

  20. Nanoelectrode array for electrochemical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yelton, William G [Sandia Park, NM; Siegal, Michael P [Albuquerque, NM

    2009-12-01

    A nanoelectrode array comprises a plurality of nanoelectrodes wherein the geometric dimensions of the electrode controls the electrochemical response, and the current density is independent of time. By combining a massive array of nanoelectrodes in parallel, the current signal can be amplified while still retaining the beneficial geometric advantages of nanoelectrodes. Such nanoelectrode arrays can be used in a sensor system for rapid, non-contaminating field analysis. For example, an array of suitably functionalized nanoelectrodes can be incorporated into a small, integrated sensor system that can identify many species rapidly and simultaneously under field conditions in high-resistivity water, without the need for chemical addition to increase conductivity.

  1. MYOPERICYTOMA OF THE TONGUE: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Sevtap Akbulut

    2013-01-01

    Full Text Available Myopericytoma is a rare benign tumour composed of pericytic cells that show myoid differentiation and have a tendency for concentric perivascular growth. It belongs to a spectrum of perivascular myoid cell neoplasms. To date, only a small number of cases of myopericytoma involving the oral cavity have been reported. We describe a case of myopericytoma presenting as a slowly growing tongue nodule in a 61-year-old woman. A diagnosis of myopericytoma was established with the histopathological findings combined with immunohistochemical staining. Myopericytoma should be included in the differential diagnosis of well-circumscribed, slow-growing lesions of the oral cavity.

  2. [Morphological changes in tongue cancer after cryosurgery].

    Science.gov (United States)

    Zhou, X D; Mao, T Q

    1993-01-01

    Tca 8113 (human tongue cancer cell line) cell transplanted tumors in nude mice were treated with cryosurgery for three freeze-thaw cycles. Tumor samples were obtained by biopsies pre- and post-cryosurgery for morphological study. The results showed intercellular adhesion damage, nuclear pyknosis, cell death, etc. One week after, the deep parts of the frozen samples were similar to that of the untreated ones. Our study indicates the change of biomembrance may be also important as of nuclei in cell death and may play an important role in the treatment of cancer by cryochemistry.

  3. Tongue prints in biometric authentication: A pilot study.

    Science.gov (United States)

    Jeddy, Nadeem; Radhika, T; Nithya, S

    2017-01-01

    Biometric authentication is an important process for the identification and verification of individuals for security purposes. There are many biometric systems that are currently in use and also being researched. Tongue print is a new biometric authentication tool that is unique and cannot be easily forged because no two tongue prints are similar. The present study aims to evaluate the common morphological features of the tongue and its variations in males and females. The usefulness of alginate impression and dental cast in obtaining the lingual impression was also evaluated. The study sample included twenty participants. The participants were subjected to visual examination following which digital photographs of the dorsal surface of the tongue were taken. Alginate impressions of the tongue were made, and casts were prepared using dental stone. The photographs and the casts were analyzed by two observers separately for the surface morphology including shape, presence or absence of fissures and its pattern of distribution. Three reference points were considered to determine the shape of the tongue. The most common morphological feature on the dorsum of the tongue was the presence of central fissures. Multiple vertical fissures were observed in males whereas single vertical fissure was a common finding in females. The fissures were predominantly shallow in males and deep in females. The tongue was predominantly U shaped in males and females. V-shaped tongue was observed in 25% of females. Tongue prints are useful in biometric authentication. The methodology used in the study is simple, easy and can be adopted by dentists on a regular basis. However, large-scale studies are required to validate the results and also identify other features of the tongue that can be used in forensics and biometric authentication process.

  4. Added clinical value of the inferior temporal EEG electrode chain

    DEFF Research Database (Denmark)

    Bach Justesen, Anders; Eskelund Johansen, Ann Berit; Martinussen, Noomi Ida

    2018-01-01

    Objective To investigate the diagnostic added value of supplementing the 10–20 EEG array with six electrodes in the inferior temporal chain. Methods EEGs were recorded with 25 electrodes: 19 positions of the 10–20 system, and six additional electrodes in the inferior temporal chain (F9/10, T9/10, P...... in the inferior chain) and 6% (only seen at the inferior chain). Conclusions Adding six electrodes in the inferior temporal electrode chain to the 10–20 array improves the localization and identification of EEG abnormalities, especially those located in the temporal region. Significance Our results suggest...

  5. Tongue coating microbiome regulates the changes in tongue texture and coating in patients with post-menopausal osteoporosis of Gan-shen deficiency syndrome type.

    Science.gov (United States)

    Liang, Wenna; Li, Xihai; Li, Yachan; Li, Candong; Gao, Bizheng; Gan, Huijuan; Li, Sumin; Shen, Jianying; Kang, Jie; Ding, Shanshan; Lin, Xuejuan; Liao, Linghong

    2013-11-01

    Tongue inspection is a unique and important method of diagnosis in traditional Chinese medicine (TCM). It is a diagnostic approach which involves observing the changes in the tongue proper and tongue coating in order to understand the physiological functions and pathological changes of the body. However, the biological basis of TCM tongue diagnosis remains to be poorly understood and lacks systematic investigation at the molecular level. In this study, we evaluated the effects of tongue coating microbiome on changes in the tongue texture and coating in patients with post-menopausal osteoporosis (PMO) of Gan‑shen deficiency syndrome type. Our aim was to delineate the mechanisms of tongue coating microbiome-induced changes in the tongue texture and coating by investigating the histomorphological changes and performing a bacterial analysis of the tongue coating. We found that the number of intermediate cells in the red tongue with a thin coating was higher, while the number of superficial cells in the red tongue with a thin coating was lower. The maturation value (MV) of tongue exfoliated cells in the red tongue with a thin coating decreased, compared with that in the pale red tongue with a thin white coating. Furthermore, the total bacterial count, oral streptococcus, Gram‑positive (G+) and Gram‑negative (G-) anaerobic bacteria in the red tongue with a thin coating was significantly decreased compared with the pale red tongue with a thin white coating. The results of ultrastructural examination demonstrated that the number of epithelial cells and bacteria in the red tongue with a thin coating decreased compared with that in the pale red tongue with a thin white coating. These observations indicate that the tongue coating microbiome may be an important factor contributing to changes in the tongue in patients with PMO of Gan‑shen deficiency syndrome type.

  6. Stretchable Micro-Electrode Arrays for Electrophysiology

    NARCIS (Netherlands)

    Khoshfetrat Pakazad, S.

    2015-01-01

    A potential serious side effect of drugs is cardiotoxicity which can result in lethal heart arrhythmias. Cardiotoxicity has been the leading cause of drug withdrawals from the market in the past decades, and has been responsible for costly failures in late stage clinical trials. This highlights the

  7. Repair of large palatal fistula using tongue flap

    Directory of Open Access Journals (Sweden)

    Fejjal Nawfal

    2014-01-01

    Full Text Available Large palatal fistulas are a challenging problem in cleft surgery. Many techniques are used to close the defect. The tongue flap is an easy and reproductible procedure for managing this complication. The authors report a case of a large palatal fistula closure with anteriorly based tongue flap.

  8. Pedagogical Competencies for Mother-Tongue Teacher Education

    Science.gov (United States)

    Mata, Liliana

    2014-01-01

    This study aims to elaborate a framework for both the foundation and application of professional standards for mother-tongue teachers. The main issue with which this study is concerned constitutes the lack of a set of clear standards for the initial training of mother-tongue teachers. In terms of theory, that which has currently been analyzed in…

  9. Learners' Motivation for Literacy in the Mother Tongue 1: Ibadan ...

    African Journals Online (AJOL)

    The study examines the desirability of and motivational needs for basic literacy in the mother tongue and library use in lbadan metropolis. Data were collected through indepth interviews with 25 adult basic learners. The study reveals a strong desire for literacy in the mother tongue by the respondents. The learners' ...

  10. Base of tongue varices associated with portal hypertension

    OpenAIRE

    Jassar, P; Jaramillo, M; Nunez, D

    2000-01-01

    A symptomatic case of tongue base varices in a patient with portal hypertension secondary to liver cirrhosis is presented. There are no previously documented cases in the world literature. Oesophageal varices may not be the only source of expectorated blood in a patient with portal hypertension.


Keywords: portal hypertension; lingual; tongue; varicose vein

  11. Dagara Tongue-Root Vowel Harmony | Kuubezelle | Ghana Journal ...

    African Journals Online (AJOL)

    Though tongue-root vowel harmony in many Ghanaian languages has been described, there still remain many others which have received little or no description at all. Dagara, a dialect of Dagaare a Mabia language, is one of such dialects. This paper presents a description of Dagara tongue-root vowel harmony using ...

  12. Discrimination of Xihulongjing tea grade using an electronic tongue ...

    African Journals Online (AJOL)

    Five grades of Xihulongjing tea (grade: AAA, AA, A, B and C, from the same region and processed with the same processing method) were discriminated using -Astree II electronic tongue (e-tongue) coupled with pattern recognition methods including principal component analysis (PCA), canonical discriminant analysis ...

  13. Spatiotemporal Coupling of the Tongue in Amyotrophic Lateral Sclerosis

    Science.gov (United States)

    Kuruvilla, Mili S.; Green, Jordan R.; Yunusova, Yana; Hanford, Kathy

    2012-01-01

    Purpose: The primary aim of the investigation was to identify deficits in spatiotemporal coupling between tongue regions in amyotrophic lateral sclerosis (ALS). The relations between disease-related changes in tongue movement patterns and speech intelligibility were also determined. Methods: The authors recorded word productions from 11…

  14. Mother tongue education: a panacea to effective teaching and ...

    African Journals Online (AJOL)

    The controversy as to whether the English Language or the child's mother tongue facilitates teaching and learning at primary school level has not been resolved. The advocates of mother-tongue medium claim that it makes for meaningful teaching and learning and better pupils' participation in the learning process while ...

  15. Mother tongue education in Kenya: significance, challenges and ...

    African Journals Online (AJOL)

    The importance of mother tongue(s) (also referred to as vernaculars or indigenous languages or African languages) in the cognitive, linguistic, personal and educational development of children cannot be overemphasized. Indeed it is out of this recognition that the UNESCO declared 2006, the Year of African Languages.

  16. Inducing Speech Errors in Dysarthria Using Tongue Twisters

    Science.gov (United States)

    Kember, Heather; Connaghan, Kathryn; Patel, Rupal

    2017-01-01

    Although tongue twisters have been widely use to study speech production in healthy speakers, few studies have employed this methodology for individuals with speech impairment. The present study compared tongue twister errors produced by adults with dysarthria and age-matched healthy controls. Eight speakers (four female, four male; mean age =…

  17. Repair of large palatal fistula using tongue flap | Nawfal | African ...

    African Journals Online (AJOL)

    Large palatal fi stulas are a challenging problem in cleft surgery. Many techniques are used to close the defect. The tongue fl ap is an easy and reproductible procedure for managing this complication. The authors report a case of a large palatal fi stula closure with anteriorly based tongue fl ap. Key words: Cleft surgery, ...

  18. Discrimination of Xihulongjing tea grade using an electronic tongue

    African Journals Online (AJOL)

    STORAGESEVER

    2009-12-15

    Dec 15, 2009 ... the same processing method) were discriminated using α-Astree II electronic tongue (e-tongue) ... discovery and quantification of many of the key taste and ..... flavonoids from tea samples of different origins by HPLC-DAD-ESI-.

  19. Malignant melanoma of the tongue following low-dose radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kalemeris, G.C.; Rosenfeld, L.; Gray, G.F. Jr.; Glick, A.D.

    1985-03-01

    A 47-year-old man had a spindly malignant melanoma of the tongue many years after low-dose radiation therapy for lichen planus. To our knowledge, only 12 melanomas of the tongue have been reported previously, and in none of these was radiation documented.

  20. Malignant melanoma of the tongue following low-dose radiation

    International Nuclear Information System (INIS)

    Kalemeris, G.C.; Rosenfeld, L.; Gray, G.F. Jr.; Glick, A.D.

    1985-01-01

    A 47-year-old man had a spindly malignant melanoma of the tongue many years after low-dose radiation therapy for lichen planus. To our knowledge, only 12 melanomas of the tongue have been reported previously, and in none of these was radiation documented

  1. Base of Tongue Tuberculosis: A Case Report

    Directory of Open Access Journals (Sweden)

    Prepageran Narayanan

    2012-02-01

    Full Text Available We report a rare case of base of tongue tuberculosis following pulmonary tuberculosis. Patient presented to us with chief complaints of sore throat and pain on swallowing for period of 3 months. On examination with 70 degree telescope, we observed an ulcer on right side of base of tongue. The edges of the ulcer appeared to be undermined with whitish slough at the centre of the ulcer. Examination of neck showed a multiple small palpable middle deep cervical lymph nodes on right side of neck. Biopsy of the ulcer was taken, which showed granulomatous inflammation, suggestive of tuberculosis. Laboratory investigations revealed a raise in erythrocyte sedimentation rate, sputum for acid fast bacilli was strongly positive. Chest X ray was performed for patient showed multiple areas of consolidation. Patient was referred to chest clinic for further management of tuberculosis and was started on anti-tuberculous drugs. In conclusion tuberculosis of oral cavity is rare, but should be considered among one of the differential diagnosis of the oral lesions and biopsy is necessary to confirm the diagnosis.

  2. Tongue-driven sonar beam steering by a lingual-echolocating fruit bat.

    Directory of Open Access Journals (Sweden)

    Wu-Jung Lee

    2017-12-01

    Full Text Available Animals enhance sensory acquisition from a specific direction by movements of head, ears, or eyes. As active sensing animals, echolocating bats also aim their directional sonar beam to selectively "illuminate" a confined volume of space, facilitating efficient information processing by reducing echo interference and clutter. Such sonar beam control is generally achieved by head movements or shape changes of the sound-emitting mouth or nose. However, lingual-echolocating Egyptian fruit bats, Rousettus aegyptiacus, which produce sound by clicking their tongue, can dramatically change beam direction at very short temporal intervals without visible morphological changes. The mechanism supporting this capability has remained a mystery. Here, we measured signals from free-flying Egyptian fruit bats and discovered a systematic angular sweep of beam focus across increasing frequency. This unusual signal structure has not been observed in other animals and cannot be explained by the conventional and widely-used "piston model" that describes the emission pattern of other bat species. Through modeling, we show that the observed beam features can be captured by an array of tongue-driven sound sources located along the side of the mouth, and that the sonar beam direction can be steered parsimoniously by inducing changes to the pattern of phase differences through moving tongue location. The effects are broadly similar to those found in a phased array-an engineering design widely found in human-made sonar systems that enables beam direction changes without changes in the physical transducer assembly. Our study reveals an intriguing parallel between biology and human engineering in solving problems in fundamentally similar ways.

  3. Added clinical value of the inferior temporal EEG electrode chain.

    Science.gov (United States)

    Bach Justesen, Anders; Eskelund Johansen, Ann Berit; Martinussen, Noomi Ida; Wasserman, Danielle; Terney, Daniella; Meritam, Pirgit; Gardella, Elena; Beniczky, Sándor

    2018-01-01

    To investigate the diagnostic added value of supplementing the 10-20 EEG array with six electrodes in the inferior temporal chain. EEGs were recorded with 25 electrodes: 19 positions of the 10-20 system, and six additional electrodes in the inferior temporal chain (F9/10, T9/10, P9/10). Five-hundred consecutive standard and sleep EEG recordings were reviewed using the 10-20 array and the extended array. We identified the recordings with EEG abnormalities that had peak negativities at the inferior temporal electrodes, and those that only were visible at the inferior temporal electrodes. From the 286 abnormal recordings, the peak negativity was at the inferior temporal electrodes in 81 cases (28.3%) and only visible at the inferior temporal electrodes in eight cases (2.8%). In the sub-group of patients with temporal abnormalities (n = 134), these represented 59% (peak in the inferior chain) and 6% (only seen at the inferior chain). Adding six electrodes in the inferior temporal electrode chain to the 10-20 array improves the localization and identification of EEG abnormalities, especially those located in the temporal region. Our results suggest that inferior temporal electrodes should be added to the EEG array, to increase the diagnostic yield of the recordings. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  4. Cermet electrode

    Science.gov (United States)

    Maskalick, Nicholas J.

    1988-08-30

    Disclosed is a cermet electrode consisting of metal particles of nickel, cobalt, iron, or alloys or mixtures thereof immobilized by zirconia stabilized in cubic form which contains discrete deposits of about 0.1 to about 5% by weight of praseodymium, dysprosium, terbium, or a mixture thereof. The solid oxide electrode can be made by covering a substrate with particles of nickel, cobalt, iron, or mixtures thereof, growing a stabilized zirconia solid oxide skeleton around the particles thereby immobilizing them, contacting the skeleton with a compound of praseodymium, dysprosium, terbium, or a mixture thereof, and heating the skeleton to a temperature of at least 500.degree. C. The electrode can also be made by preparing a slurry of nickel, cobalt, iron, or mixture and a compound of praseodymium, dysprosium, terbium, or a mixture thereof, depositing the slurry on a substrate, heating the slurry to dryness, and growing a stabilized zirconia skeleton around the metal particles.

  5. ParselTongue: AIPS Talking Python

    Science.gov (United States)

    Kettenis, M.; van Langevelde, H. J.; Reynolds, C.; Cotton, B.

    2006-07-01

    After more than 20 years of service, classic AIPS still is the data reduction package of choice for many radio-interferometry projects, especially for VLBI. Its age shows, most prominently in the limited scripting capabilities of its user interface: POPS. ParselTongue is an attempt to make the trusted AIPS algorithms and AIPS data structures available in a modern dynamic programming language: Python. It also provides an environment to do distributed computing to take advantage of modern computing clusters. This makes it suitable for use as a scripting interface for doing complicated data reduction on large data sets. It is also used as a coding platform for the new calibration algorithms that are being developed for the European VLBI Network as part of the ALBUS project. Here we hope to take advantage of Python's extensive support for web-based technologies to automate things like collecting calibration data.

  6. Living in limbo: Being diagnosed with oral tongue cancer

    Directory of Open Access Journals (Sweden)

    Genevieve Philiponis

    2015-01-01

    Full Text Available Objective: Oral tongue cancer presents clinical challenges to effective diagnosis that affect patient experience. Patient experience of the diagnostic process is poorly described, making opportunities for nursing intervention unclear. Methods: We qualitatively describe, using constant comparative analysis, oral tongue cancer diagnosis using data from a larger grounded theory study of oral tongue cancer survivorship. Using constant comparative analysis - in keeping with the methodology of the main study - we analyzed 16 survivor interviews for themes explaining the patient experience of oral tongue cancer diagnosis. Results: We termed the broader diagnostic process "living in limbo." This process includes the themes describing the peri-diagnostic process itself - "self-detected lesion," "lack of concern," "seeking help," "not a straightforward diagnosis," and "hearing the diagnosis." Entry into treatment concludes "Living in Limbo" and is described by the theme "worry and trust." Conclusions: Our findings are limited by retrospective interviews and participant homogeneity among other features. Future research with prospective designs and diverse groups of people at risk for and diagnosed with oral tongue cancer, as well as targeting those who have had negative biopsies with no eventual diagnosis of oral tongue cancer, will build on our findings. Further, study of patient experience in other sociocultural context and healthcare systems is needed to inform nursing science and practice. Finally, "living in limbo" suggests that clinician and public education about oral tongue cancer diagnosis is needed.

  7. Tongue prints: A novel biometric and potential forensic tool.

    Science.gov (United States)

    Radhika, T; Jeddy, Nadeem; Nithya, S

    2016-01-01

    Tongue is a vital internal organ well encased within the oral cavity and protected from the environment. It has unique features which differ from individual to individual and even between identical twins. The color, shape, and surface features are characteristic of every individual, and this serves as a tool for identification. Many modes of biometric systems have come into existence such as fingerprint, iris scan, skin color, signature verification, voice recognition, and face recognition. The search for a new personal identification method secure has led to the use of the lingual impression or the tongue print as a method of biometric authentication. Tongue characteristics exhibit sexual dimorphism thus aiding in the identification of the person. Emerging as a novel biometric tool, tongue prints also hold the promise of a potential forensic tool. This review highlights the uniqueness of tongue prints and its superiority over other biometric identification systems. The various methods of tongue print collection and the classification of tongue features are also elucidated.

  8. Mood-induced variations of mandible and tongue postures.

    Science.gov (United States)

    Bourdiol, P; Mishellany-Dutour, A; Peyron, M-A; Woda, A

    2013-06-01

    Twelve young adults in a good general health were observed during habitual posture of tongue and jaw in different emotional conditions induced by watching three video sequences. The position of the mandible was tracked by the displacements of an electromagnetic sensor glued to the chin. The tongue-to-palate distance was obtained by 2-D location of three electromagnetic sensors placed on the tongue upper midline surface. Head displacements were evaluated with a sensor fixed to an upper central incisor and were subtracted from corresponding displacements of tongue and chin sensors to obtain the real tongue and mandible positions during continuous recording sequences. Emotional conditioning by a fear movie influenced the vertical position of the mandible: the mean interarch distances during the fear movie (2·34 ± 0·24 mm) were significantly different from those measured during the tender (3·13 ± 0·35) and neutral (3·42 ± 0·80) movies, respectively (anova repeated measure, SNK; P < 0·05). anova repeated measure indicated that the tongue-to-palate distance differed significantly when the subjects were watching the conditioning movies (P = 0·003), the tip of the tongue taking a lower position during the fear movie than during the tender and neutral movies. © 2013 John Wiley & Sons Ltd.

  9. Etching holes in graphene supercapacitor electrodes for faster performance

    International Nuclear Information System (INIS)

    Ervin, Matthew H

    2015-01-01

    Graphene is being widely investigated as a material to replace activated carbon in supercapacitor (electrochemical capacitor) electrodes. Supercapacitors have much higher energy density, but are typically slow devices (∼0.1 Hz) compared to other types of capacitors. Here, top-down semiconductor processing has been applied to graphene-based electrodes in order to fabricate ordered arrays of holes through the graphene electrodes. This is demonstrated to increase the speed of the electrodes by reducing the ionic impedance through the electrode thickness. This approach may also be applicable to speeding up other types of devices, such as batteries and sensors, that use porous electrodes. (special)

  10. Etching holes in graphene supercapacitor electrodes for faster performance.

    Science.gov (United States)

    Ervin, Matthew H

    2015-06-12

    Graphene is being widely investigated as a material to replace activated carbon in supercapacitor (electrochemical capacitor) electrodes. Supercapacitors have much higher energy density, but are typically slow devices (∼0.1 Hz) compared to other types of capacitors. Here, top-down semiconductor processing has been applied to graphene-based electrodes in order to fabricate ordered arrays of holes through the graphene electrodes. This is demonstrated to increase the speed of the electrodes by reducing the ionic impedance through the electrode thickness. This approach may also be applicable to speeding up other types of devices, such as batteries and sensors, that use porous electrodes.

  11. Tongue Growth during Prenatal Development in Korean Fetuses and Embryos

    Directory of Open Access Journals (Sweden)

    Soo Jeong Hong

    2015-11-01

    Full Text Available Background: Prenatal tongue development may affect oral-craniofacial structures, but this muscular organ has rarely been investigated. Methods: In order to document the physiology of prenatal tongue growth, we histologically examined the facial and cranial base structures of 56 embryos and 106 fetuses. Results: In Streeter’s stages 13–14 (fertilization age [FA], 28 to 32 days, the tongue protruded into the stomodeal cavity from the retrohyoid space to the cartilaginous mesenchyme of the primitive cranial base, and in Streeter’s stage 15 (FA, 33 to 36 days, the tongue rapidly swelled and compressed the cranial base to initiate spheno-occipital synchondrosis and continued to swell laterally to occupy most of the stomodeal cavity in Streeter’s stage 16–17 (FA, 37 to 43 days. In Streeter’s stage 18–20 (FA, 44 to 51 days, the tongue was vertically positioned and filled the posterior nasopharyngeal space. As the growth of the mandible and maxilla advanced, the tongue was pulled down and protruded anteriorly to form the linguomandibular complex. Angulation between the anterior cranial base (ACB and the posterior cranial base (PCB was formed by the emerging tongue at FA 4 weeks and became constant at approximately 124°–126° from FA 6 weeks until birth, which was consistent with angulations measured on adult cephalograms. Conclusions: The early clockwise growth of the ACB to the maxillary plane became harmonious with the counter-clockwise growth of the PCB to the tongue axis during the early prenatal period. These observations suggest that human embryonic tongue growth affects ACB and PCB angulation, stimulates maxillary growth, and induces mandibular movement to achieve the essential functions of oral and maxillofacial structures.

  12. Production of pulsed electric fields using capacitively coupled electrodes

    Science.gov (United States)

    Kendall, B. R. F.; Schwab, F. A. S.

    1980-01-01

    It is shown that pulsed electric fields can be produced over extended volumes by taking advantage of the internal capacitances in a stacked array of electrodes. The design, construction, and performance of practical arrays are discussed. The prototype arrays involved fields of 100-1000 V/cm extending over several centimeters. Scaling to larger physical dimensions is straightforward.

  13. Magnetohydrodynamic electrode

    International Nuclear Information System (INIS)

    1980-01-01

    The object of the invention is the provision of a material capable of withstanding a high-temperature, corrosive and erosive environment for use as a ceramic-metal composite electrode current collector in the channel of a magnetohydrodynamic generator. (U.K.)

  14. Malignant rhabdoid tumor of the tongue: A rare occurrence.

    Science.gov (United States)

    Hazarika, Munlima; Rahman, Tashnin; Sarma, Anupam; Krishnatreya, Manigreeva

    2014-05-01

    Malignant rhabdoid tumors (MRTs) are highly aggressive neoplasms that most commonly occur in the kidneys of young children. Malignant rhabdoid tumor of the tongue is an extremely rare entity and very few have been reported in the literature. The course of extra-renal MRT is short and its prognosis is very poor. A 19-year-old female presented with a progressive swelling and restricted mobility of the tongue for over 3 months duration. We present here a locally advanced case of MRT of the tongue, its diagnosis, management and review of the literature related to it.

  15. Force and complexity of tongue task training influences behavioral measures of motor learning

    DEFF Research Database (Denmark)

    Kothari, Mohit; Svensson, Peter; Huo, Xueliang

    2012-01-01

    Relearning of motor skills is important in neurorehabilitation. We investigated the improvement of training success during simple tongue protrusion (two force levels) and a more complex tongue-training paradigm using the Tongue Drive System (TDS). We also compared subject-based reports of fun, pain...... training influences behavioral aspects of tongue motor learning....

  16. Round window electrode insertion potentiates retention in the scala tympani.

    Science.gov (United States)

    Connor, Stephen E J; Holland, N Julian; Agger, Andreas; Leong, Annabelle C; Varghese, Re Ajay; Jiang, Dan; Fitzgerald O'Connor, Alec

    2012-09-01

    The round window membrane (RWM)-intentioned approach is superior to the traditional bony cochleostomy (BC) approach in obtaining electrode placement within the scala tympani (ST). Cochlear implant outcome is influenced by several factors, including optimal placement and retention of the electrode array within the ST. The present study aimed to assess whether the RWM route is superior to a traditional BC for placement and retention of the electrode array in the ST. This was a prospective consecutive non-randomized comparison study. All patients were implanted with the Advanced Bionics 1J electrode array. The RWM approach (n = 32) was compared with a traditional BC group (n = 33). The outcome measure was the electrode position as judged within the scalar chambers at four points along the basal turn using postoperative computed tomography (CT). When the mean position scores were compared, the RWM-intentioned group had significantly more electrodes directed towards the ST compartment than the BC group (p scala vestibuli.

  17. Functional MRI of tongue motor tasks in patients with tongue cancer: observations before and after partial glossectomy

    International Nuclear Information System (INIS)

    Haupage, Samantha; Branski, Ryan C.; Kraus, Dennis; Peck, Kyung K.; Hsu, Meier; Holodny, Andrei

    2010-01-01

    The current study seeks to provide preliminary data regarding this central, adaptive response during tongue motor tasks utilizing functional magnetic resonance imaging (fMRI) before and after glossectomy. Six patients, with confirmed histological diagnoses of oral tongue cancer, underwent fMRI before and 6 months after partial glossectomy. These data were compared to nine healthy controls. All subjects performed three tongue motor tasks during fMRI: tongue tapping (TT), dry swallow (Dry), and wet swallow (Wet). Following surgery, increased activation was subjectively observed in the superior parietal lobule, supplementary motor area, and anterior cingulate. Region of interest (ROI) analysis of the precentral gyrus confirmed increased cortical activity following surgery. In addition, comparisons between pre-surgical scans and controls suggested the dry swallow task was sensitive to elicit tongue-related activation in the precentral gyrus (p ≤ 0.05). The adaptive changes in the cortex following partial glossectomy reflect recruitment of the parietal, frontal, and cingulate cortex during tongue motor tasks. In addition, post-operative activation patterns more closely approximated control levels than the pre-operative scans. Furthermore, the dry swallow task appears most specific to elicit tongue-related cortical activity. (orig.)

  18. Functional MRI of tongue motor tasks in patients with tongue cancer: observations before and after partial glossectomy

    Energy Technology Data Exchange (ETDEWEB)

    Haupage, Samantha; Branski, Ryan C.; Kraus, Dennis [Memorial Sloan-Kettering Cancer Center, Head and Neck Surgery, New York, NY (United States); Peck, Kyung K. [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York, NY (United States); Memorial Sloan-Kettering Cancer Center, Medical Physics, New York, NY (United States); Memorial Sloan-Kettering Cancer Center, Department of Medical Physics and Radiology, New York, NY (United States); Hsu, Meier [Memorial Sloan-Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States); Holodny, Andrei [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York, NY (United States)

    2010-12-15

    The current study seeks to provide preliminary data regarding this central, adaptive response during tongue motor tasks utilizing functional magnetic resonance imaging (fMRI) before and after glossectomy. Six patients, with confirmed histological diagnoses of oral tongue cancer, underwent fMRI before and 6 months after partial glossectomy. These data were compared to nine healthy controls. All subjects performed three tongue motor tasks during fMRI: tongue tapping (TT), dry swallow (Dry), and wet swallow (Wet). Following surgery, increased activation was subjectively observed in the superior parietal lobule, supplementary motor area, and anterior cingulate. Region of interest (ROI) analysis of the precentral gyrus confirmed increased cortical activity following surgery. In addition, comparisons between pre-surgical scans and controls suggested the dry swallow task was sensitive to elicit tongue-related activation in the precentral gyrus (p {<=} 0.05). The adaptive changes in the cortex following partial glossectomy reflect recruitment of the parietal, frontal, and cingulate cortex during tongue motor tasks. In addition, post-operative activation patterns more closely approximated control levels than the pre-operative scans. Furthermore, the dry swallow task appears most specific to elicit tongue-related cortical activity. (orig.)

  19. Functional anatomy of the hypoglossal innervated muscles of the rat tongue: a model for elongation and protrusion of the mammalian tongue.

    Science.gov (United States)

    McClung, J R; Goldberg, S J

    2000-12-01

    This anatomical investigation in the rat was designed to illustrate the detailed organization of the tongue's muscles and their innervation in order to elucidate the actions of the muscles of the higher mammalian tongue and thereby clarify the protrusor subdivision of the hypoglossal-tongue complex. The hypoglossal innervated, extrinsic styloglossus, hyoglossus, and genioglossus and the intrinsic transversus, verticalis and longitudinalis linguae muscles were observed by microdissection and analysis of serial transverse-sections of the tongue. Sihler's staining technique was applied to whole rat tongues to demonstrate the hypoglossal nerve branching patterns. Dissections of the tongue demonstrate the angles at which the extrinsic muscles act on the base of the tongue. The Sihler stained hypoglossal nerves demonstrate branches to the styloglossus and hyoglossus emanating from its lateral division while branches to the genioglossus muscle exit from its medial division. The largest portions of both XIIth nerve divisions can be seen to enter the body of the tongue to innervate the intrinsic muscles. Transverse sections of the tongue demonstrate the organization of the intrinsic muscle fibers of the tongue. Longitudinal muscle fibers run along the entire circumference of the tongue. Alternating sheets of transverse lingual and vertical lingual muscles can be observed to insert into the circumference of the tongue. Most importantly in clarifying tongue protrusion, we demonstrate the transversus muscle fibers enveloping the most superior and inferior portions of the longitudinalis muscles. Longitudinal muscle fascicles are completely encircled and thus are likely to be compressed by transverse muscle fascicles resulting in elongation of the tongue. We discuss our findings in relation to biomechanical studies, that describe the tongue as a muscular hydrostat and thereby define the "elongation-protrusion apparatus" of the mammalian tongue. In so doing, we clarify the

  20. Electrode Processes in Porous Electrodes.

    Science.gov (United States)

    1985-11-26

    F104470 2.0 MASS SPECTROMETRY One part of activity for this year is an investigation of the behavior of silver electrodes through the distribution of...al. (2)). These, in some cases, involve tedious and time comsuming procedures and discrepencies of as much as 15% have been observed in the results. As

  1. Contrastive analysis in mother tongue teaching in Sweden – teacher’sperceptions and practices

    OpenAIRE

    Reis, Marina

    2017-01-01

    This study is about contrastive analysis in mother tongue teaching in Sweden. Contrastive analysis between mother tongue and Swedish is part of the Swedish syllabus for the school subject mother tongue and is therefore a pertinent subject to be investigated. The study analyzes how five mother tongue teachers in a medium-sized Swedish city work with contrastive analysis in their classes and how they evaluate the importance of this content in mother tongue teaching. The question concerning the ...

  2. Carcinoma of the tongue in Norway and Wisconsin. I

    International Nuclear Information System (INIS)

    Vermund, H.

    1982-01-01

    The records of 503 patients with carcinoma of the tongue diagnosed between 1958 and 1972 were reviewed. The preponderance of tongue carcinoma among men was confirmed both in The Norwegian Radium Hospital (NRH) and the University of Wisconsin Hospitals (UW), but it was relatively more frequent among women in NRH and in UW than in southern Europe. More women had on presentation less advanced tumors at NRH than at UW. The incidence of tongue carcinoma in Norway increased steadily with age for both sexes. The sex ratio did not change in Norway such as in England, Canada and the United States. Tumor of the posterior one-third of the tongue was relatively infrequent in women both in NRH and UW, in agreement with reports from other countries. The length of survival was analysed and no significant sex difference was demonstrated. The younger patients had less advanced tumors and a better prognosis. (Auth.)

  3. Expression of FGFs during early mouse tongue development

    Czech Academy of Sciences Publication Activity Database

    Du, W.; Procházka, Jan; Procházková, Michaela; Klein, O.D.

    2016-01-01

    Roč. 20, č. 2 (2016), s. 81-87 ISSN 1567-133X Institutional support: RVO:68378050 Keywords : Tongue * FGF * Expression * Papilla Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 1.158, year: 2016

  4. Tooth brushing, tongue cleaning and snacking behaviour of dental ...

    African Journals Online (AJOL)

    2010-08-12

    Aug 12, 2010 ... frequency, duration and technique of tooth brushing and tongue cleaning as well as information on ... All the students in Year 1Б4 were included in the study. .... agents which are beneficial for prevention and treatment.

  5. Tongue-Driven Wheelchair Out-Maneuvers the Competition

    Science.gov (United States)

    ... 2, 2014 Tongue-Driven Wheelchair Out-Maneuvers the Competition Researchers funded by the National Institute of Biomedical ... significant step towards vastly improving the independence and quality of life of individuals with tetraplegia, and is ...

  6. Dental and oral complications of lip and tongue piercings.

    Science.gov (United States)

    De Moor, R J G; De Witte, A M J C; Delmé, K I M; De Bruyne, M A A; Hommez, G M G; Goyvaerts, D

    2005-10-22

    Piercing of the tongue and perioral regions is an increasingly popular expression of body art, with more patients coming in for a routine check-up with tongue and/or lip piercings. Several complications of oral piercing have been reported, some of which are life-threatening. In the present clinical survey the prevalence of both tongue and lip piercing complications in oral health was assessed in a group of 50 patients. The most common dental problem registered was chipping of the teeth, especially in association with tongue piercing. Gingival recession was seen as a result of lip piercing with studs. Post-procedural complications included oedema, haemorrhage and infection. Therefore, dentists and oral and maxillofacial surgeons should be given more authority to advise patients with oral and facial piercings or those who plan to acquire this type of body art.

  7. The right to mother tongue education: a multidisciplinary, normative ...

    African Journals Online (AJOL)

    (4) of the National Education Policy Act (1996), the Department of Education recognises the benefits to be derived from mother-tongue education and commits itself to an additive approach to bilingualism within the education system.

  8. Bilingual Children's Mother Tongue: Why is it important in for

    African Journals Online (AJOL)

    Midaso

    Both African and international second language studies show that children who go ... Due to this lack of development of mother tongue languages, Kenya like ..... is strengthened and this increases motivation and initiative as well as creativity.

  9. Marriage, Sexuality and Moral Responsibility among the Tongu Mafi ...

    African Journals Online (AJOL)

    2016-03-21

    Mar 21, 2016 ... practices of the Tongu Mafi people of Ghana reveals that marriage rites and ... religious values and practices with the larger Ewe community. However, the ...... cooking responsibilities. ... of 'dirty money' and source of wealth.

  10. Congenital Midline Tongue Base Mass in An Infant: Lingual Hamartoma

    OpenAIRE

    Fadzilah, Noraziana; Azman, Mawaddah; See, Goh Bee

    2016-01-01

    Lingual hamartoma is a rare finding of congenital midline posterior tongue mass. The lesion may be seen as a single anomaly or maybe associated with syndrome especially the Oral Facial Digital Syndrome (OFDS). Here, we report an otherwise normal and healthy two-month-old boy with a congenital midline base of tongue mass presented with snoring and episodic vomiting since the age of 1 month. Tumour excision from the area of foramen of caecum recovered a pinkish pedunculated tumour. Histopatholo...

  11. Linezolid induced black hairy tongue: a rare side effect.

    Science.gov (United States)

    Aijazi, Ishma; Abdulla, Fadhil M

    2014-01-01

    Linezolid induced black hairy tongue is a rare benign reversible side effect of linezolid therapy. We report a case of a 61 year old diabetic lady who developed thrombocytopenia and black hairy discoloration of the tongue after being prescribed linezolid for foot osteomyelitis by the orthopaedic surgeon. Patient was encouraged to practice good oral dental hygiene, advised to use a soft tooth brush, regular mouth wash and baking soda containing tooth paste. The condition resolved four weeks after cessation of the antibiotic therapy.

  12. Neck-tongue syndrome on sudden turning of the head.

    Science.gov (United States)

    Lance, J W; Anthony, M

    1980-01-01

    A syndrome of unilateral upper nuchal or occipital pain, with or without numbness in these areas, accompanied by simultaneous ipsilateral numbness of the tongue is explicable by compression of the second cervical root in the atlantoaxial space on sharp rotation of the neck. Afferents fibres from the lingual nerve travelling via the hypoglossal nerve to the second cervical root provide a plausible anatomical explanation for compression of that root causing numbness of half the tongue. PMID:7359159

  13. Tongue color changes within a menstrual cycle in eumenorrheic women

    Directory of Open Access Journals (Sweden)

    Shu-Feng Hsieh

    2016-07-01

    Full Text Available Tongue color (舌色 shé sè has been used to diagnose abnormal body conditions for thousands of years in traditional Chinese Medicine (中醫 zhōng yī. However, it is not clear whether tongue color alters with physiological changes within a normal menstrual cycle (月經周期 yuè jīng zhōu qī. This study investigated difference in tongue color between the follicular phase and luteal phase in eumenorrheic women. Tongue surface photographs were taken in the follicular phase and the luteal phase of thirty-two volunteers with biphasic basal body temperature. Color values on five areas of the tongue surface were examined and comparisons of color values were made between the two phases according to the red–green–blue (RGB, hue–saturation–brightness (HSB, luminance-a-b (Lab, and cyan–magenta–yellow–black (CMYK models. Based on the RGB model, the values of green and blue in the tip area were larger in the follicular phase than both in the luteal phase. The values of magenta and yellow based in the CMYK model were smaller in the tip area in the follicular phase than that in the luteal phase. The saturation in the tip area was smaller in the follicular phase than that in the luteal phase. Based on the Lab model, b value in the middle area was smaller in the follicular phase than that in the luteal phase. The data revealed that tongue color varied within a eumenorrheic menstrual cycle, suggesting that tongue color differences between the follicular and luteal phases need to be considered while practicing tongue diagnosis (舌診 shé zhěn or performing clinical studies among childbearing women.

  14. The carcinomas tongue-incidence risk factor, presentation and treatment

    International Nuclear Information System (INIS)

    Asif, M.; Mazafar, K.

    2000-01-01

    The tongue is one of the common site for the development of carcinoma in the oral cavity. A prospective study was done from 1st January 1995 to 30th November, 1995. A total of 47 new cases of the oral cavity cancer were seen during this period. Out of which 10 (21.3%) cases were of tongue carcinoma and it was found to be the commonest tumor of the oral cavity. Surgery was the best option for early lesions. (author)

  15. Passive wireless tags for tongue controlled assistive technology interfaces

    Science.gov (United States)

    Rakibet, Osman O.; Horne, Robert J.; Kelly, Stephen W.

    2016-01-01

    Tongue control with low profile, passive mouth tags is demonstrated as a human–device interface by communicating values of tongue-tag separation over a wireless link. Confusion matrices are provided to demonstrate user accuracy in targeting by tongue position. Accuracy is found to increase dramatically after short training sequences with errors falling close to 1% in magnitude with zero missed targets. The rate at which users are able to learn accurate targeting with high accuracy indicates that this is an intuitive device to operate. The significance of the work is that innovative very unobtrusive, wireless tags can be used to provide intuitive human–computer interfaces based on low cost and disposable mouth mounted technology. With the development of an appropriate reading system, control of assistive devices such as computer mice or wheelchairs could be possible for tetraplegics and others who retain fine motor control capability of their tongues. The tags contain no battery and are intended to fit directly on the hard palate, detecting tongue position in the mouth with no need for tongue piercings. PMID:27222736

  16. Do long-term tongue piercings affect speech quality?

    Science.gov (United States)

    Heinen, Esther; Birkholz, Peter; Willmes, Klaus; Neuschaefer-Rube, Christiane

    2017-10-01

    To explore possible effects of tongue piercing on perceived speech quality. Using a quasi-experimental design, we analyzed the effect of tongue piercing on speech in a perception experiment. Samples of spontaneous speech and read speech were recorded from 20 long-term pierced and 20 non-pierced individuals (10 males, 10 females each). The individuals having a tongue piercing were recorded with attached and removed piercing. The audio samples were blindly rated by 26 female and 20 male laypersons and by 5 female speech-language pathologists with regard to perceived speech quality along 5 dimensions: speech clarity, speech rate, prosody, rhythm and fluency. We found no statistically significant differences for any of the speech quality dimensions between the pierced and non-pierced individuals, neither for the read nor for the spontaneous speech. In addition, neither length nor position of piercing had a significant effect on speech quality. The removal of tongue piercings had no effects on speech performance either. Rating differences between laypersons and speech-language pathologists were not dependent on the presence of a tongue piercing. People are able to perfectly adapt their articulation to long-term tongue piercings such that their speech quality is not perceptually affected.

  17. Ultrasonography in the evaluation of tongue and mouth pathology

    International Nuclear Information System (INIS)

    Lee, Chan Wha; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Lee, Jong Tae; Hong, Won Pyo; Park, Hyung Sik

    1991-01-01

    The evaluation of the tongue and mouth floor using the CT scan can be limited due to dental artifacts. Because the therapeutic plan depends on the nature and the cancer staging of lesions, it is essential to obtain accurate evaluation of lesions. In this study are explored the of Ultrasonography for the evaluation of tongue and mouth floor pathology. We have obtained ultrasonograms in 20 patients who had benign and malignant lesions in the tongue and mouth floor. Comparative analysis was made on 15 patients who underwent both CT and ultrasonography. We used the bimanual compression technique and the phonation technique during real-time scanning. Out of 15 cases, six had tongue cancer, and seven of them had cancer of the mouth floor. The other cases included a ranula, a dermoid cyst, a Ludwig's angina, and abscess of salivary gland, and one care with stones of the submandibular gland. All the benign and malignant masses appeared hypoechoic. Even though the lesions of tongue and mouth floor could not be evaluated by CT scan due to dental artifacts and extremely small size in 5 cases, ultrasonogram using the bimanual compression technique demonstrated good localization of the lesion, and also was greatly helpful in visualizing the invasion of the surrounding structures. Ultrasonography of the tongue and mouth floor proved to be superior to the CT scan not only in delineating the size and extent of the primary lesion, but also in visualizing invasion of surrounding structures

  18. X-ray detector array

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    The object of the invention (an ionization chamber X-ray detector array for use with high speed computerised tomographic imaging apparatus) is to reduce the time required to produce a tomographic image. The detector array described determines the distribution of X-ray intensities in one or more flat, coplanar X-ray beams. It comprises three flat anode sheets parallel to the X-ray beam, a plurality of rod-like cathodes between the anodes, a detector gas between the electrodes and a means for applying a potential between the electrodes. Each of the X-ray sources is collimated to give a narrow, planar section of X-ray photons. Sets of X-ray sources in the array are pulsed simultaneously to obtain X-ray transmission data for tomographic image reconstruction. (U.K.)

  19. Functional outcome of tongue motions with selective hypoglossal nerve stimulation in patients with obstructive sleep apnea.

    Science.gov (United States)

    Heiser, C; Maurer, J T; Steffen, A

    2016-05-01

    Selective upper airway stimulation of the hypoglossal nerve is a novel therapy option for obstructive sleep apnea. Different tongue motions were observed after surgery during active therapy. We examined tongue motions in 14 patients (mean age 51 ± 10 years) who received an implantation of an upper airway stimulation system (Inspire Medical Systems) from September 2013 to February 2014 in three different implantation centers in Germany after surgery. Sleep recording was performed preoperatively: 2 months (M02) and 6 months (M06) after surgery. There were three different tongue motions observed after surgery at 1 month (M01), M02, and M06 after surgery: bilateral protrusion (BP), right protrusion (RP), and mixed activation (MA). At M01: 10 BP, 2 RP, and 2 MA; at M02: 12 BP, 0 RP, and 2 MA; and at M06: 12 BP, 0 RP, and 2 MA could be detected. The average apnea-hypopnea index (AHI) was reduced from 32.5 ± 14.2/h before surgery to 17.9 ± 23.3/h at M02 and 14.1 ± 19.8/h at M06. An increased reduction in AHI was found in BP and RP group (Baseline: 29.6 ± 12.6/h; M02: 12.06 ± 14.1/h; M06: 9.7 ± 12.6/h) compared to the MA group (Baseline 49.6 ± 13.8/h; M02: 49.7 ± 5.1/h; M06: 40.5 ± 4.1/h). These findings suggest that the postoperative tongue motions in upper airway stimulation are associated with the therapy outcome. The stimulation electrode placement on the hypoglossal nerve for selective muscle recruitment may play a role in the mechanism of action.

  20. Radium therapy for carcinoma of the tongue

    International Nuclear Information System (INIS)

    Matsuura, Shizumi; Makino, Sohtaro; Satake, Bunsuke; Takahashi, Keiichi; Sakaino, Kohji; Nakajima, Nobuaki

    1984-01-01

    Results of radium therapy with or without multi-disciplinary treatment for carcinoma of the tongue were studied in 117 patients treated from 1973 to 1981 at Gunma Cancer Center. 1. The patients were classified according to the TNM classification of UICC (1978). Seventeen patients were T1, 42 were T2, 31 were T3, 27 were T4, 92 were NO, 18 were N1, 2 were N2 and 5 were N3. 2. The treatment methods included external irradiation with 1,000-2,000 rads by 6MV X-ray followed by radium interstitial implants of 6,000-8,000 rads in 93 patients (73.9 per cent), radium therapy with additional Bleomycin 45-60 mg in 24 patients (20.5 per cent), and cryosurgery in 3 patients. 3. The five year survival rate was 41.6 per cent; 100.0 per cent for T1, 50.0 per cent for T2, 38.8 per cent for T3 and 10.5 per cent for T4. The overall five-year cumulative survival rate was 46.9 per cent. For primary lesions of T3 or T4, greater efforts should be made with combined modalities, such as planned multi-disciplinary treatments with combined radiation and major surgery. (author)

  1. The Mother Tongue of Leila Sebbar

    Directory of Open Access Journals (Sweden)

    Danielle Marx-Scouras

    1993-01-01

    Full Text Available Leila Sebbar grew up in French colonial Algeria where her parents taught French to the indigenous children. The daughter of a metropolitan French woman and an Algerian, Sebbar is a croisée . At the height of the Algerian War, Sebbar left her homeland to pursue her university studies in France. She became a French teacher and made France her home. Sebbar writes in her mother tongue, but she treats it like a foreign language. Although she never learned Arabic and left Algeria, her paternal identity haunts all of her writings. Anchored by the notion of exile, Sebbar drifts between two shores as she seeks to personally come to terms with both a pied-noir and Algerian identity bequeathed by her parents. This dual and contradictory identity allows Sebbar to explore the colonial legacy inherent to immigration in France. Continually on the move or on the run, Sebbar's eccentric protagonists follow a geographical itinerary which acknowledges the common history and cultural heritage of Europe and the Arab world. In forging a new identity for the France of tomorrow, this génération métisse attempts to work through the torturous relationship between France and its former colonies that continues to mark cultural manifestations and political events in France.

  2. Portable Electronic Tongue Based on Microsensors for the Analysis of Cava Wines.

    Science.gov (United States)

    Giménez-Gómez, Pablo; Escudé-Pujol, Roger; Capdevila, Fina; Puig-Pujol, Anna; Jiménez-Jorquera, Cecilia; Gutiérrez-Capitán, Manuel

    2016-10-27

    Cava is a quality sparkling wine produced in Spain. As a product with a designation of origin, Cava wine has to meet certain quality requirements throughout its production process; therefore, the analysis of several parameters is of great interest. In this work, a portable electronic tongue for the analysis of Cava wine is described. The system is comprised of compact and low-power-consumption electronic equipment and an array of microsensors formed by six ion-selective field effect transistors sensitive to pH, Na⁺, K⁺, Ca 2+ , Cl - , and CO₃ 2- , one conductivity sensor, one redox potential sensor, and two amperometric gold microelectrodes. This system, combined with chemometric tools, has been applied to the analysis of 78 Cava wine samples. Results demonstrate that the electronic tongue is able to classify the samples according to the aging time, with a percentage of correct prediction between 80% and 96%, by using linear discriminant analysis, as well as to quantify the total acidity, pH, volumetric alcoholic degree, potassium, conductivity, glycerol, and methanol parameters, with mean relative errors between 2.3% and 6.0%, by using partial least squares regressions.

  3. Portable Electronic Tongue Based on Microsensors for the Analysis of Cava Wines

    Directory of Open Access Journals (Sweden)

    Pablo Giménez-Gómez

    2016-10-01

    Full Text Available Cava is a quality sparkling wine produced in Spain. As a product with a designation of origin, Cava wine has to meet certain quality requirements throughout its production process; therefore, the analysis of several parameters is of great interest. In this work, a portable electronic tongue for the analysis of Cava wine is described. The system is comprised of compact and low-power-consumption electronic equipment and an array of microsensors formed by six ion-selective field effect transistors sensitive to pH, Na+, K+, Ca2+, Cl−, and CO32−, one conductivity sensor, one redox potential sensor, and two amperometric gold microelectrodes. This system, combined with chemometric tools, has been applied to the analysis of 78 Cava wine samples. Results demonstrate that the electronic tongue is able to classify the samples according to the aging time, with a percentage of correct prediction between 80% and 96%, by using linear discriminant analysis, as well as to quantify the total acidity, pH, volumetric alcoholic degree, potassium, conductivity, glycerol, and methanol parameters, with mean relative errors between 2.3% and 6.0%, by using partial least squares regressions.

  4. Geographic Tongue and Fissured Tongue in 348 Patients with Psoriasis: Correlation with Disease Severity

    Directory of Open Access Journals (Sweden)

    Bruna L. S. Picciani

    2015-01-01

    Full Text Available Geographic tongue (GT and fissured tongue (FT are the more frequent oral lesions in patients with psoriasis. The aims of this study were to compare the prevalence of GT/FT between psoriasis group (PG and healthy controls (HC and investigate the correlation between GT/FT and psoriasis severity using the PASI and age of psoriasis onset. Three hundred and forty-eight PG and 348 HC were selected. According to the age of psoriasis onset, the individuals were classified as having early psoriasis and late psoriasis. The severity of vulgaris psoriasis was determined according to PASI. A follow-up was conducted in patients with psoriasis vulgaris (PV with GT to evaluate the progression of oral and cutaneous lesions. The FT and GT were more frequent in PG than in HC. The incidence of GT was higher in patients with early psoriasis and that of FT in late-psoriasis. There is association between psoriasis intensity and GT; and a higher monthly decrease of PASI score in patients without GT. The presence of GT and FT is higher in PG than in the HC. GT is associated with disease severity and may be a marker of the psoriasis severity.

  5. A reciprocity-based formula for the capacitance with quadrupolar electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sungbo [Gachon University of Medicine and Science, Incheon (Korea, Republic of)

    2011-11-15

    A new capacitance formula for the practical design and characterization of quadrupolar electrode arrays with capacitive structures was derived based on the reciprocal theorem. The reciprocity-based capacitance formula agreed with the empirical equations established to estimate the capacitance of a single strip line or disk electrode compensating for the fringing field effect that occurs at the electrode edge. The reciprocity-based formula was applied to compute the capacitance measurable by using a quadrupolar square electrode array with a symmetric dipole-dipole configuration and was compared with the analytical equation established based on the image method assuming that the electrodes were points. The results showed that the capacitance of the quadrupolar electrodes was determined by the size of the quadrupolar electrodes relative to the separation distance between the electrodes and that the reciprocity-based capacitance formula was in agreement with the established analytical equation if the separated distance between the electrodes relative to the electrode size was large enough.

  6. A reciprocity-based formula for the capacitance with quadrupolar electrodes

    International Nuclear Information System (INIS)

    Cho, Sungbo

    2011-01-01

    A new capacitance formula for the practical design and characterization of quadrupolar electrode arrays with capacitive structures was derived based on the reciprocal theorem. The reciprocity-based capacitance formula agreed with the empirical equations established to estimate the capacitance of a single strip line or disk electrode compensating for the fringing field effect that occurs at the electrode edge. The reciprocity-based formula was applied to compute the capacitance measurable by using a quadrupolar square electrode array with a symmetric dipole-dipole configuration and was compared with the analytical equation established based on the image method assuming that the electrodes were points. The results showed that the capacitance of the quadrupolar electrodes was determined by the size of the quadrupolar electrodes relative to the separation distance between the electrodes and that the reciprocity-based capacitance formula was in agreement with the established analytical equation if the separated distance between the electrodes relative to the electrode size was large enough.

  7. Oral tongue cancer gene expression profiling: Identification of novel potential prognosticators by oligonucleotide microarray analysis

    International Nuclear Information System (INIS)

    Estilo, Cherry L; Boyle, Jay O; Kraus, Dennis H; Patel, Snehal; Shaha, Ashok R; Wong, Richard J; Huryn, Joseph M; Shah, Jatin P; Singh, Bhuvanesh; O-charoenrat, Pornchai; Talbot, Simon; Socci, Nicholas D; Carlson, Diane L; Ghossein, Ronald; Williams, Tijaana; Yonekawa, Yoshihiro; Ramanathan, Yegnanarayana

    2009-01-01

    The present study is aimed at identifying potential candidate genes as prognostic markers in human oral tongue squamous cell carcinoma (SCC) by large scale gene expression profiling. The gene expression profile of patients (n=37) with oral tongue SCC were analyzed using Affymetrix HG-U95Av2 high-density oligonucleotide arrays. Patients (n=20) from which there were available tumor and matched normal mucosa were grouped into stage (early vs. late) and nodal disease (node positive vs. node negative) subgroups and genes differentially expressed in tumor vs. normal and between the subgroups were identified. Three genes, GLUT3, HSAL2, and PACE4, were selected for their potential biological significance in a larger cohort of 49 patients via quantitative real-time RT-PCR. Hierarchical clustering analyses failed to show significant segregation of patients. In patients (n=20) with available tumor and matched normal mucosa, 77 genes were found to be differentially expressed (P< 0.05) in the tongue tumor samples compared to their matched normal controls. Among the 45 over-expressed genes, MMP-1 encoding interstitial collagenase showed the highest level of increase (average: 34.18 folds). Using the criterion of two-fold or greater as overexpression, 30.6%, 24.5% and 26.5% of patients showed high levels of GLUT3, HSAL2 and PACE4, respectively. Univariate analyses demonstrated that GLUT3 over-expression correlated with depth of invasion (P<0.0001), tumor size (P=0.024), pathological stage (P=0.009) and recurrence (P=0.038). HSAL2 was positively associated with depth of invasion (P=0.015) and advanced T stage (P=0.047). In survival studies, only GLUT3 showed a prognostic value with disease-free (P=0.049), relapse-free (P=0.002) and overall survival (P=0.003). PACE4 mRNA expression failed to show correlation with any of the relevant parameters. The characterization of genes identified to be significant predictors of prognosis by oligonucleotide microarray and further validation by

  8. Taste Receptor Signaling-- From Tongues to Lungs

    Science.gov (United States)

    Kinnamon, Sue C.

    2013-01-01

    Taste buds are the transducing endorgans of gustation. Each taste bud comprises 50–100 elongated cells, which extend from the basal lamina to the surface of the tongue, where their apical microvilli encounter taste stimuli in the oral cavity. Salts and acids utilize apically located ion channels for transduction, while bitter, sweet and umami (glutamate) stimuli utilize G protein coupled receptors (GPCRs) and second messenger signaling mechanisms. This review will focus on GPCR signaling mechanisms. Two classes of taste GPCRs have been identified, the T1Rs for sweet and umami (glutamate) stimuli, and the T2Rs for bitter stimuli. These low affinity GPCRs all couple to the same downstream signaling effectors that include Gβγ activation of PLCβ2, IP3-mediated release of Ca2+ from intracellular stores, and Ca2+-dependent activation of the monovalent selective cation channel, TrpM5. These events lead to membrane depolarization, action potentials, and release of ATP as a transmitter to activate gustatory afferents. The Gα subunit, α-gustducin, activates a phosphodiesterase to decrease intracellular cAMP levels, although the precise targets of cAMP have not been identified. With the molecular identification of the taste GPCRs, it has become clear that taste signaling is not limited to taste buds, but occurs in many cell types of the airways. These include solitary chemosensory cells, ciliated epithelial cells, and smooth muscle cells. Bitter receptors are most abundantly expressed in the airways, where they respond to irritating chemicals and promote protective airway reflexes, utilizing the same downstream signaling effectors as taste cells. PMID:21481196

  9. Transcriptomic dissection of tongue squamous cell carcinoma

    Directory of Open Access Journals (Sweden)

    Schwartz Joel L

    2008-02-01

    Full Text Available Abstract Background The head and neck/oral squamous cell carcinoma (HNOSCC is a diverse group of cancers, which develop from many different anatomic sites and are associated with different risk factors and genetic characteristics. The oral tongue squamous cell carcinoma (OTSCC is one of the most common types of HNOSCC. It is significantly more aggressive than other forms of HNOSCC, in terms of local invasion and spread. In this study, we aim to identify specific transcriptomic signatures that associated with OTSCC. Results Genome-wide transcriptomic profiles were obtained for 53 primary OTSCCs and 22 matching normal tissues. Genes that exhibit statistically significant differences in expression between OTSCCs and normal were identified. These include up-regulated genes (MMP1, MMP10, MMP3, MMP12, PTHLH, INHBA, LAMC2, IL8, KRT17, COL1A2, IFI6, ISG15, PLAU, GREM1, MMP9, IFI44, CXCL1, and down-regulated genes (KRT4, MAL, CRNN, SCEL, CRISP3, SPINK5, CLCA4, ADH1B, P11, TGM3, RHCG, PPP1R3C, CEACAM7, HPGD, CFD, ABCA8, CLU, CYP3A5. The expressional difference of IL8 and MMP9 were further validated by real-time quantitative RT-PCR and immunohistochemistry. The Gene Ontology analysis suggested a number of altered biological processes in OTSCCs, including enhancements in phosphate transport, collagen catabolism, I-kappaB kinase/NF-kappaB signaling cascade, extracellular matrix organization and biogenesis, chemotaxis, as well as suppressions of superoxide release, hydrogen peroxide metabolism, cellular response to hydrogen peroxide, keratinization, and keratinocyte differentiation in OTSCCs. Conclusion In summary, our study provided a transcriptomic signature for OTSCC that may lead to a diagnosis or screen tool and provide the foundation for further functional validation of these specific candidate genes for OTSCC.

  10. [Methodological study on digitalization of tongue image in traditional Chinese medical diagnosis].

    Science.gov (United States)

    Zhou, Yue; Yang, Jie; Shen, Li

    2004-12-01

    This is a research aimed at proposing a computerized tongue analysis method based on computerized image processing for quantizing the tongue properties in traditional Chinese medical diagnosis. The chromatic algorithm and 2-D Gabor wavelet transformation are applied to segmenting tongue from original image. The statistical method is adopted in identifying the colors of each pixel, which are attributed to the tongue substance and coating respectively. Thickness of tongue coating is determined by energy of 2-D Gabor wavelet coefficients (GWTE). The distribution of GWTE and invariant moment algorithm are used to judge the tongue texture. The experiment result shows that all methods proposed in this paper are effective.

  11. Surgical implications of perimodiolar cochlear implant electrode design: avoiding intracochlear damage and scala vestibuli insertion.

    Science.gov (United States)

    Briggs, R J; Tykocinski, M; Saunders, E; Hellier, W; Dahm, M; Pyman, B; Clark, G M

    2001-09-01

    To review the mechanisms and nature of intracochlear damage associated with cochlear implant electrode array insertion, in particular, the various perimodiolar electrode designs. Make recommendations regarding surgical techniques for the Nucleus Contour electrode to ensure correct position and minimal insertion trauma. The potential advantages of increased modiolar proximity of intracochlear multichannel electrode arrays are a reduction in stimulation thresholds, an increase in dynamic range and more localized neural excitation. This may improve speech perception and reduce power consumption. These advantages may be negated if increased intracochlear damage results from the method used to position the electrodes close to the modiolus. A review of the University of Melbourne Department of Otolaryngology experience with temporal bone safety studies using the Nucleus standard straight electrode array and a variety of perimodiolar electrode array designs; comparison with temporal bone insertion studies from other centres and postmortem histopathology studies reported in the literature. Review of our initial clinical experience using the Nucleus Contour electrode array. The nature of intracochlear damage resulting from electrode insertion trauma ranges from minor, localized, spiral ligament tear to diffuse organ of Corti disruption and osseous spiral lamina fracture. The type of damage depends on the mechanical characteristics of the electrode array, the stiffness, curvature and size of the electrode in relation to the scala, and the surgical technique. The narrow, flexible, straight arrays are the least traumatic. Pre-curved or stiffer arrays are associated with an incidence of basilar membrane perforation. The cochleostomy must be correctly sited in relation to the round window to ensure scala tympani insertion. A cochleostomy anterior to the round window rather than inferior may lead to scala media or scala vestibuli insertion. Proximity of electrodes to the modiolus

  12. A Fast SVM-Based Tongue's Colour Classification Aided by k-Means Clustering Identifiers and Colour Attributes as Computer-Assisted Tool for Tongue Diagnosis

    Science.gov (United States)

    Ooi, Chia Yee; Kawanabe, Tadaaki; Odaguchi, Hiroshi; Kobayashi, Fuminori

    2017-01-01

    In tongue diagnosis, colour information of tongue body has kept valuable information regarding the state of disease and its correlation with the internal organs. Qualitatively, practitioners may have difficulty in their judgement due to the instable lighting condition and naked eye's ability to capture the exact colour distribution on the tongue especially the tongue with multicolour substance. To overcome this ambiguity, this paper presents a two-stage tongue's multicolour classification based on a support vector machine (SVM) whose support vectors are reduced by our proposed k-means clustering identifiers and red colour range for precise tongue colour diagnosis. In the first stage, k-means clustering is used to cluster a tongue image into four clusters of image background (black), deep red region, red/light red region, and transitional region. In the second-stage classification, red/light red tongue images are further classified into red tongue or light red tongue based on the red colour range derived in our work. Overall, true rate classification accuracy of the proposed two-stage classification to diagnose red, light red, and deep red tongue colours is 94%. The number of support vectors in SVM is improved by 41.2%, and the execution time for one image is recorded as 48 seconds. PMID:29065640

  13. A Fast SVM-Based Tongue's Colour Classification Aided by k-Means Clustering Identifiers and Colour Attributes as Computer-Assisted Tool for Tongue Diagnosis.

    Science.gov (United States)

    Kamarudin, Nur Diyana; Ooi, Chia Yee; Kawanabe, Tadaaki; Odaguchi, Hiroshi; Kobayashi, Fuminori

    2017-01-01

    In tongue diagnosis, colour information of tongue body has kept valuable information regarding the state of disease and its correlation with the internal organs. Qualitatively, practitioners may have difficulty in their judgement due to the instable lighting condition and naked eye's ability to capture the exact colour distribution on the tongue especially the tongue with multicolour substance. To overcome this ambiguity, this paper presents a two-stage tongue's multicolour classification based on a support vector machine (SVM) whose support vectors are reduced by our proposed k -means clustering identifiers and red colour range for precise tongue colour diagnosis. In the first stage, k -means clustering is used to cluster a tongue image into four clusters of image background (black), deep red region, red/light red region, and transitional region. In the second-stage classification, red/light red tongue images are further classified into red tongue or light red tongue based on the red colour range derived in our work. Overall, true rate classification accuracy of the proposed two-stage classification to diagnose red, light red, and deep red tongue colours is 94%. The number of support vectors in SVM is improved by 41.2%, and the execution time for one image is recorded as 48 seconds.

  14. Improvements in tongue strength and pressure-generation precision following a tongue-pressure training protocol in older individuals with dysphagia: three case reports.

    Science.gov (United States)

    Yeates, Erin M; Molfenter, Sonja M; Steele, Catriona M

    2008-01-01

    Dysphagia, or difficulty swallowing, often occurs secondary to conditions such as stroke, head injury or progressive disease, many of which increase in frequency with advancing age. Sarcopenia, the gradual loss of muscle bulk and strength, can place older individuals at greater risk for dysphagia. Data are reported for three older participants in a pilot trial of a tongue-pressure training therapy. During the experimental therapy protocol, participants performed isometric strength exercises for the tongue as well as tongue pressure accuracy tasks. Biofeedback was provided using the Iowa Oral Performance Instrument (IOPI), an instrument that measures tongue pressure. Treatment outcome measures show increased isometric tongue strength, improved tongue pressure generation accuracy, improved bolus control on videofluoroscopy, and improved functional dietary intake by mouth. These preliminary results indicate that, for these three adults with dysphagia, tongue-pressure training was beneficial for improving both instrumental and functional aspects of swallowing. The experimental treatment protocol holds promise as a rehabilitative tool for various dysphagia populations.

  15. Tongue-to-palate resistance training improves tongue strength and oropharyngeal swallowing function in subacute stroke survivors with dysphagia.

    Science.gov (United States)

    Kim, H D; Choi, J B; Yoo, S J; Chang, M Y; Lee, S W; Park, J S

    2017-01-01

    Tongue function can affect both the oral and pharyngeal stages of the swallowing process, and proper tongue strength is vital for safe oropharyngeal swallowing. This trial investigated the effect of tongue-to-palate resistance training (TPRT) on tongue strength and oropharyngeal swallowing function in stroke with dysphagia patients. This trial was performed using a 4-week, two-group, pre-post-design. Participants were allocated to the experimental group (n = 18) or the control group (n = 17). The experimental group performed TPRT for 4 weeks (5 days per week) and traditional dysphagia therapy, whereas the control group performed traditional dysphagia therapy on the same schedule. Tongue strength was measured using the Iowa Oral Performance Instrument. Swallowing function was measured using the videofluoroscopic dysphagia scale (VDS) and penetration-aspiration scale (PAS) based on a videofluoroscopic swallowing study. Experimental group showed more improved in the tongue strength (both anterior and posterior regions, P = 0·009, 0·015). In addition, the experimental group showed more improved scores on the oral and pharyngeal phase of VDS (P = 0·029, 0·007), but not on the PAS (P = 0·471), compared with the control group. This study demonstrated the effectiveness of TPRT in increasing tongue muscle strength and improving swallowing function in patients with post-stroke dysphagia. Therefore, we recommend TPRT as an easy and simple rehabilitation strategy for improving swallowing in patients with dysphagia. © 2016 John Wiley & Sons Ltd.

  16. Policy and experiment in mother tongue literacy in Nigeria

    Science.gov (United States)

    Akinnaso, F. Niyi

    1993-07-01

    The advocacy for initial mother tongue literacy in elementary schools and in adult education has been intensified within the past three decades, reflecting new attitudes to cultural diversity, especially to multilingual and multicultural education. This paper assesses the efforts made in one country, Nigeria, to achieve mother tongue literacy for its citizens, through a comparative analysis of the national policy on mother tongue literacy and the Ife experimental project, whose major purpose was to test the effectiveness of the use of the mother tongue as a medium of instruction throughout the six years of primary education. Although, like the Ife project, many experimental projects on mother tongue literacy in other countries are shown to have succeeded in realizing their objectives, the findings highlight the mediating effects of several non-linguistic variables. The findings indicate that its use as the medium of instruction in schools cannot compensate for the deficiencies in the educational system, particularly poor quality instructional facilities, or the social barriers in the wider society which prevent certain groups of minority children from learning well in school. The implications of the findings are discussed.

  17. Cine-MRI swallowing evaluation after tongue reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Hartl, Dana M. [Department of Otolaryngology-Head and Neck Surgery, Institute Gustave Roussy, 39 rue Camille Desmoulins, 94805 Villejuif Cedex (France)], E-mail: dmhartl@aol.com; Kolb, Frederic; Bretagne, Evelyne [Department of Otolaryngology-Head and Neck Surgery, Institute Gustave Roussy, 39 rue Camille Desmoulins, 94805 Villejuif Cedex (France); Bidault, Francois; Sigal, Robert [Department of Radiology, Institut Gustave Roussy, 39 rue Camille Desmoulins, 94805 Villejuif Cedex (France)

    2010-01-15

    Objective: To determine the feasibility of cine-MRI for non-invasive swallowing evaluation after surgery for lingual carcinoma with reconstruction using microvascular free flaps. Methods: Ten patients with stage IV carcinoma of the mobile tongue and/or tongue base treated by surgical resection and reconstruction with a free flap were evaluated after an average of 4.3 years (range: 1.5-11 years), using cine-MRI in 'single-shot fast spin echo' (SSFSE) mode. Fiberoptic laryngoscopy of swallowing was performed before MRI to detect aspiration. The tolerance and ability to complete the exam were noted. The mobilities of the oral and pharyngeal structures visualized were evaluated as normal, reduced or increased. Results: Cine-MRI was well tolerated in all cases; 'dry' swallow was performed for the 2 patients with clinical aspiration. Tongue base-pharyngeal wall contact was observed in 5 cases. An increased anterior tongue recoil, increased mandibular recoil, increased posterior oropharyngeal wall advancement and an increased laryngeal elevation were observed in 4 cases. One case of a passive 'slide' mechanism was observed. Conclusions: Cine-MRI is a safe, non-invasive technique for the evaluation of the mobility of oral and oropharyngeal structures after free-flap reconstruction of the tongue. For selected cases, it may be complementary to clinical examination for evaluation of dysphagia after surgery and free-flap reconstruction. Further technical advances will be necessary before cine-MRI can replace videofluoroscopy, however.

  18. Analysis of Tonguing and Blowing Actions During Clarinet Performance

    Directory of Open Access Journals (Sweden)

    Montserrat Pàmies-Vilà

    2018-04-01

    Full Text Available Articulation on the clarinet is achieved by a combination of precise actions taking place inside the player's mouth. With the aim to analyse the effects of tonguing and blowing actions during playing, several physical variables are measured and parameters related to articulation are studied. Mouth pressure, mouthpiece pressure and reed displacement are recorded in an experiment with clarinet players to evaluate the influence of the player's actions on the selected parameters and on the sound. The results show that different combinations of tongue and blowing actions are used during performance. Portato and legato playing show constant blowing throughout the musical phrase, which varies according to the dynamic level. In portato, short tongue-reed interaction is used homogeneously among players and playing conditions. In staccato playing, where the tongue-reed contact is longer, the mouth pressure is reduced significantly between notes. Such a mouth-pressure decrease might be used to stop the note in slow staccato playing. It is hereby shown that when the note is stopped by the action of the tongue both the attack and release transients are shorter compared to the case where the vibration of the reed is stopped by a decrease of mouth pressure.

  19. Does Mother Tongue Interfere in Second Language Learning?

    Directory of Open Access Journals (Sweden)

    Elif Nur Denizer

    2017-01-01

    Full Text Available Mother tongue largely refers to not only the language one learns from one’s mother but also the speaker’s dominant and home language. It’s also called native language. This study was conducted to find whether mother tongue interferences in second-language learning, and if so; whether it affects the learners’ performance in four language skills, and also in which skill(s it has the biggest effect. Data collection tool included a questionnaire by which participants were asked to rate the questions and tick-circle or write in the correct blank. The questionnaire was based on both quantitative and qualitative approaches with the help of 4-point Likert-scale questions and one open-ended question at the last part. The participants of the study were 20 volunteer students (15 females and 5 males in Uludag University on whom the questionnaire was randomly applied.  They ranged in age from 18 to 40 and the mean age was 23. Their mother tongue was Turkish, and they knew English as a foreign language. The questionnaire shows that mother tongue interferes with second language learning in some way. In English language, the most challenging part was Grammar, while the most difficult and influenced skills was Speaking. In addition, participants had difficulty with speaking without any preparation. When it comes to having difficulty, participants had difficulty with determiners, English tenses and articles. The results indicated the interference of mother tongue in almost all aspects.

  20. Analysis of Tonguing and Blowing Actions During Clarinet Performance.

    Science.gov (United States)

    Pàmies-Vilà, Montserrat; Hofmann, Alex; Chatziioannou, Vasileios

    2018-01-01

    Articulation on the clarinet is achieved by a combination of precise actions taking place inside the player's mouth. With the aim to analyse the effects of tonguing and blowing actions during playing, several physical variables are measured and parameters related to articulation are studied. Mouth pressure, mouthpiece pressure and reed displacement are recorded in an experiment with clarinet players to evaluate the influence of the player's actions on the selected parameters and on the sound. The results show that different combinations of tongue and blowing actions are used during performance. Portato and legato playing show constant blowing throughout the musical phrase, which varies according to the dynamic level. In portato, short tongue-reed interaction is used homogeneously among players and playing conditions. In staccato playing, where the tongue-reed contact is longer, the mouth pressure is reduced significantly between notes. Such a mouth-pressure decrease might be used to stop the note in slow staccato playing. It is hereby shown that when the note is stopped by the action of the tongue both the attack and release transients are shorter compared to the case where the vibration of the reed is stopped by a decrease of mouth pressure.

  1. Tongue thickness relates to nutritional status in the elderly.

    Science.gov (United States)

    Tamura, Fumiyo; Kikutani, Takeshi; Tohara, Takashi; Yoshida, Mitsuyoshi; Yaegaki, Ken

    2012-12-01

    Many elderly people under long-term care suffer from malnutrition caused by dysphagia, frequently leading to sarcopenia. Our hypothesis is that sarcopenia may compromise oral function, resulting in dysphagia. The objectives of this study were to evaluate sarcopenia of the lingual muscles by measuring the tongue thickness, and elucidate its relationship with nutritional status. We examined 104 elderly subjects (mean age = 80.3 ± 7.9 years). Anthropometric data, such as triceps skinfold thickness and midarm muscle area (AMA), were obtained. The tongue thickness of the central part was determined using ultrasonography. Measurement was performed twice and the mean value was obtained. The relationship between tongue thickness and nutritional status was analyzed by Pearson's correlation coefficient and Spearman's rank correlation coefficient. AMA and age were identified by multiple-regression analysis as factors influencing tongue thickness. The results of this study suggest that malnutrition may induce sarcopenia not only in the skeletal muscles but also in the tongue.

  2. Review on the current trends in tongue diagnosis systems

    Directory of Open Access Journals (Sweden)

    Chang Jin Jung

    2012-12-01

    Full Text Available Tongue diagnosis is an essential process to noninvasively assess the condition of a patient's internal organs in traditional medicine. To obtain quantitative and objective diagnostic results, image acquisition and analysis devices called tongue diagnosis systems (TDSs are required. These systems consist of hardware including cameras, light sources, and a ColorChecker, and software for color correction, segmentation of tongue region, and tongue classification. To improve the performance of TDSs, various types TDSs have been developed. Hyperspectral imaging TDSs have been suggested to acquire more information than a two-dimensional (2D image with visible light waves, as it allows collection of data from multiple bands. Three-dimensional (3D imaging TDSs have been suggested to provide 3D geometry. In the near future, mobile devices like the smart phone will offer applications for assessment of health condition using tongue images. Various technologies for the TDS have respective unique advantages and specificities according to the application and diagnostic environment, but this variation may cause inconsistent diagnoses in practical clinical applications. In this manuscript, we reviewed the current trends in TDSs for the standardization of systems. In conclusion, the standardization of TDSs can supply the general public and oriental medical doctors with convenient, prompt, and accurate information with diagnostic results for assessing the health condition.

  3. Cine-MRI swallowing evaluation after tongue reconstruction

    International Nuclear Information System (INIS)

    Hartl, Dana M.; Kolb, Frederic; Bretagne, Evelyne; Bidault, Francois; Sigal, Robert

    2010-01-01

    Objective: To determine the feasibility of cine-MRI for non-invasive swallowing evaluation after surgery for lingual carcinoma with reconstruction using microvascular free flaps. Methods: Ten patients with stage IV carcinoma of the mobile tongue and/or tongue base treated by surgical resection and reconstruction with a free flap were evaluated after an average of 4.3 years (range: 1.5-11 years), using cine-MRI in 'single-shot fast spin echo' (SSFSE) mode. Fiberoptic laryngoscopy of swallowing was performed before MRI to detect aspiration. The tolerance and ability to complete the exam were noted. The mobilities of the oral and pharyngeal structures visualized were evaluated as normal, reduced or increased. Results: Cine-MRI was well tolerated in all cases; 'dry' swallow was performed for the 2 patients with clinical aspiration. Tongue base-pharyngeal wall contact was observed in 5 cases. An increased anterior tongue recoil, increased mandibular recoil, increased posterior oropharyngeal wall advancement and an increased laryngeal elevation were observed in 4 cases. One case of a passive 'slide' mechanism was observed. Conclusions: Cine-MRI is a safe, non-invasive technique for the evaluation of the mobility of oral and oropharyngeal structures after free-flap reconstruction of the tongue. For selected cases, it may be complementary to clinical examination for evaluation of dysphagia after surgery and free-flap reconstruction. Further technical advances will be necessary before cine-MRI can replace videofluoroscopy, however.

  4. Tongue-mandible coupling movements during saliva swallowing.

    Science.gov (United States)

    Bourdiol, P; Mishellany-Dutour, A; Peyron, M-A; Woda, A

    2014-03-01

    The purpose of this study was to measure the tongue and mandible positions and displacements in relation to the maxilla in the midsagittal plane to characterize the different saliva swallowing patterns by recording their kinematics. A 2D electromagnetic articulograph using four transducer coils, three attached to the upper surface of the tongue midline plus one attached to the chin anterior part allowed continuous evaluation of tongue and chin movements in twelve young adults in good general health. During 170 s sequences recorded at a frequency of 100 Hz, subjects were at rest, silently reading a text they had chosen. The subjects were free to swallow during the sequence. Deglutition of accumulated saliva was analysed after averaging all values obtained during successive 250 ms periods. We identified three elementary swallowing patterns. Mean duration of tongue-mandible movements were 1·51 ± 0·17 s, 1·63 ± 0·14 s and 2·00 ± 0·08 s for the first, second and third patterns respectively. In the light of other studies based on intra-oral pressure recordings, our results help to understand the tongue-mandible coupling behaviours involved in managing an in-mouth saliva bolus during the three elementary swallowing patterns identified. © 2014 John Wiley & Sons Ltd.

  5. Tongue Images Classification Based on Constrained High Dispersal Network

    Directory of Open Access Journals (Sweden)

    Dan Meng

    2017-01-01

    Full Text Available Computer aided tongue diagnosis has a great potential to play important roles in traditional Chinese medicine (TCM. However, the majority of the existing tongue image analyses and classification methods are based on the low-level features, which may not provide a holistic view of the tongue. Inspired by deep convolutional neural network (CNN, we propose a novel feature extraction framework called constrained high dispersal neural networks (CHDNet to extract unbiased features and reduce human labor for tongue diagnosis in TCM. Previous CNN models have mostly focused on learning convolutional filters and adapting weights between them, but these models have two major issues: redundancy and insufficient capability in handling unbalanced sample distribution. We introduce high dispersal and local response normalization operation to address the issue of redundancy. We also add multiscale feature analysis to avoid the problem of sensitivity to deformation. Our proposed CHDNet learns high-level features and provides more classification information during training time, which may result in higher accuracy when predicting testing samples. We tested the proposed method on a set of 267 gastritis patients and a control group of 48 healthy volunteers. Test results show that CHDNet is a promising method in tongue image classification for the TCM study.

  6. Review on the current trends in tongue diagnosis systems.

    Science.gov (United States)

    Jung, Chang Jin; Jeon, Young Ju; Kim, Jong Yeol; Kim, Keun Ho

    2012-12-01

    Tongue diagnosis is an essential process to noninvasively assess the condition of a patient's internal organs in traditional medicine. To obtain quantitative and objective diagnostic results, image acquisition and analysis devices called tongue diagnosis systems (TDSs) are required. These systems consist of hardware including cameras, light sources, and a ColorChecker, and software for color correction, segmentation of tongue region, and tongue classification. To improve the performance of TDSs, various types TDSs have been developed. Hyperspectral imaging TDSs have been suggested to acquire more information than a two-dimensional (2D) image with visible light waves, as it allows collection of data from multiple bands. Three-dimensional (3D) imaging TDSs have been suggested to provide 3D geometry. In the near future, mobile devices like the smart phone will offer applications for assessment of health condition using tongue images. Various technologies for the TDS have respective unique advantages and specificities according to the application and diagnostic environment, but this variation may cause inconsistent diagnoses in practical clinical applications. In this manuscript, we reviewed the current trends in TDSs for the standardization of systems. In conclusion, the standardization of TDSs can supply the general public and oriental medical doctors with convenient, prompt, and accurate information with diagnostic results for assessing the health condition.

  7. The Electrode Modality Development in Pulsed Electric Field Treatment Facilitates Biocellular Mechanism Study and Improves Cancer Ablation Efficacy.

    Science.gov (United States)

    Cen, Chao; Chen, Xinhua

    2017-01-01

    Pulsed electric field treatment is now widely used in diverse biological and medical applications: gene delivery, electrochemotherapy, and cancer therapy. This minimally invasive technique has several advantages over traditional ablation techniques, such as nonthermal elimination and blood vessel spare effect. Different electrodes are subsequently developed for a specific treatment purpose. Here, we provide a systematic review of electrode modality development in pulsed electric field treatment. For electrodes invented for experiment in vitro, sheet electrode and electrode cuvette, electrodes with high-speed fluorescence imaging system, electrodes with patch-clamp, and electrodes with confocal laser scanning microscopy are introduced. For electrodes invented for experiment in vivo, monopolar electrodes, five-needle array electrodes, single-needle bipolar electrode, parallel plate electrodes, and suction electrode are introduced. The pulsed electric field provides a promising treatment for cancer.

  8. CT Accuracy of Extrinsic Tongue Muscle Invasion in Oral Cavity Cancer.

    Science.gov (United States)

    Junn, J C; Baugnon, K L; Lacayo, E A; Hudgins, P A; Patel, M R; Magliocca, K R; Corey, A S; El-Deiry, M; Wadsworth, J T; Beitler, J J; Saba, N F; Liu, Y; Aiken, A H

    2017-02-01

    Extrinsic tongue muscle invasion in oral cavity cancer upstages the primary tumor to a T4a. Despite this American Joint Committee on Cancer staging criterion, no studies have investigated the accuracy or prognostic importance of radiologic extrinsic tongue muscle invasion, the feasibility of standardizing extrinsic tongue muscle invasion reporting, or the degree of agreement across different disciplines: radiology, surgery, and pathology. The purpose of this study was to assess the agreement among radiology, surgery, and pathology for extrinsic tongue muscle invasion and to determine the imaging features most predictive of extrinsic tongue muscle invasion with surgical/pathologic confirmation. Thirty-three patients with untreated primary oral cavity cancer were included. Two head and neck radiologists, 3 otolaryngologists, and 1 pathologist prospectively evaluated extrinsic tongue muscle invasion. Fourteen of 33 patients had radiologic extrinsic tongue muscle invasion; however, only 8 extrinsic tongue muscle invasions were confirmed intraoperatively. Pathologists were unable to determine extrinsic tongue muscle invasion in post-formalin-fixed samples. Radiologic extrinsic tongue muscle invasion had 100% sensitivity, 76% specificity, 57% positive predictive value, and 100% negative predictive value with concurrent surgical-pathologic evaluation of extrinsic tongue muscle invasion as the criterion standard. On further evaluation, the imaging characteristic most consistent with surgical-pathologic evaluation positive for extrinsic tongue muscle invasion was masslike enhancement. Evaluation of extrinsic tongue muscle invasion is a subjective finding for all 3 disciplines. For radiology, masslike enhancement of extrinsic tongue muscle invasion most consistently corresponded to concurrent surgery/pathology evaluation positive for extrinsic tongue muscle invasion. Intraoperative surgical and pathologic evaluation should be encouraged to verify radiologic extrinsic tongue

  9. Array capabilities and future arrays

    International Nuclear Information System (INIS)

    Radford, D.

    1993-01-01

    Early results from the new third-generation instruments GAMMASPHERE and EUROGAM are confirming the expectation that such arrays will have a revolutionary effect on the field of high-spin nuclear structure. When completed, GAMMASHPERE will have a resolving power am order of magnitude greater that of the best second-generation arrays. When combined with other instruments such as particle-detector arrays and fragment mass analysers, the capabilites of the arrays for the study of more exotic nuclei will be further enhanced. In order to better understand the limitations of these instruments, and to design improved future detector systems, it is important to have some intelligible and reliable calculation for the relative resolving power of different instrument designs. The derivation of such a figure of merit will be briefly presented, and the relative sensitivities of arrays currently proposed or under construction presented. The design of TRIGAM, a new third-generation array proposed for Chalk River, will also be discussed. It is instructive to consider how far arrays of Compton-suppressed Ge detectors could be taken. For example, it will be shown that an idealised open-quote perfectclose quotes third-generation array of 1000 detectors has a sensitivity an order of magnitude higher again than that of GAMMASPHERE. Less conventional options for new arrays will also be explored

  10. Modeling of Transient Nectar Flow in Hummingbird Tongues

    Science.gov (United States)

    Rico-Guevara, Alejandro; Fan, Tai-Hsi; Rubega, Margaret

    2015-11-01

    We demonstrate that hummingbirds do not pick up floral nectar via capillary action. The long believed capillary rise models were mistaken and unable to predict the dynamic nectar intake process. Instead, hummingbird's tongue acts as an elastic micropump. Nectar is drawn into the tongue grooves during elastic expansion after the grooves are squeezed flat by the beak. The new model is compared with experimental data from high-speed videos of 18 species and tens of individuals of wild hummingbirds. Self-similarity and transitions of short-to-long time behaviours have been resolved for the nectar flow driven by expansive filling. The transient dynamics is characterized by the relative contributions of negative excess pressure and the apparent area modulus of the tongue grooves.

  11. Cavernous hemangioma of the tongue: A rare case report

    Directory of Open Access Journals (Sweden)

    K A Kamala

    2014-01-01

    Full Text Available Hemangiomas are developmental vascular abnormalities and more than 50% of these lesions occur in the head and neck region, with the lips, tongue, buccal mucosa, and palate most commonly involved. They are considered as hamartomas rather than true neoplasms. Here we report a case of hemangioma of the body of the tongue, discussing the diagnostic aspects and treatment modalities of such lesion and emphasizing the role of the color Doppler ultrasonography, especially in the diagnosis and treatment. Factors such as patient′s age, size and site of lesion and the proximity of lesion to vital structure are paramount in the determination of the therapeutic approach and surgical excision. Even though radiotherapy, cryotherapy, laser therapy, medical treatment, injection of sclerosing substances and the selective embolization of the lingual artery seem to have some efficacy, the author conclude that surgery is the therapy of choice in the isolated vascular lesions of the body of the tongue.

  12. The in-capillary DPPH-capillary electrophoresis-the diode array detector combined with reversed-electrode polarity stacking mode for screening and quantifying major antioxidants in Cuscuta chinensis Lam.

    Science.gov (United States)

    Liu, Jiao; Tian, Ji; Li, Jin; Azietaku, John Teye; Zhang, Bo-Li; Gao, Xiu-Mei; Chang, Yan-Xu

    2016-07-01

    An in-capillary 2, 2-diphenyl-1-picrylhydrazyl (DPPH)-CE-the DAD (in-capillary DPPH-CE-DAD) combined with reversed-electrode polarity stacking mode has been developed to screen and quantify the active antioxidant components of Cuscuta chinensis Lam. The operation parameters were optimized with regard to the pH and concentration of buffer solution, SDS, β-CDs, organic modifier, as well as separation voltage and temperature. Six antioxidants including chlorogenic acid, p-coumaric acid, rutin, hyperin, isoquercitrin, and astragalin were screened and the total antioxidant activity of the complex matrix was successfully evaluated based on the decreased peak area of DPPH by the established DPPH-CE-DAD method. Sensitivity was enhanced under reversed-electrode polarity stacking mode and 10- to 31-fold of magnitude improvement in detection sensitivity for each analyte was attained. The results demonstrated that the newly established in-capillary DPPH-CE-DAD method combined with reversed-electrode polarity stacking mode could integrate sample concentration, the oxidizing reaction, separation, and detection into one capillary to fully automate the system. It was considered a suitable technique for the separation, screening, and determination of trace antioxidants in natural products. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Slotted coax as a beam electrode

    International Nuclear Information System (INIS)

    Lambertson, G.R.; Kim, K.J.; Voelker, F.V.

    1983-03-01

    The slot coupled TEM line has been employed at CERN as a pick up electrode in the GHz range. It is a compact and broad band device, and will be quite attractive if the coupling efficiency is competitive with an array of quarter wave loops. In this paper, we study various properties of such a structure

  14. Controversies in the management of tongue base cancer.

    LENUS (Irish Health Repository)

    O'Neill, J P

    2012-01-31

    BACKGROUND: Tongue base cancer is one of the most lethal head and neck cancers. There is considerable controversy in the management of this disease with wide variation of opinion within the literature. METHODS: We discuss the presentation, diagnostic and therapeutic strategies which exist in the literature. Articles were reviewed from 1970 to 2007 within the Medline, Pubmed and Cochrane libraries. CONCLUSIONS: Smokers with a history of persistent unilateral neck pain, even in the absence of clinical signs warrant MRI neck imaging. Tongue base cancer organ preservation therapeutic strategies, radiation and concomitant platinum based chemotherapy, currently optimise oncologic and quality of life outcomes.

  15. Cartilaginous choristoma of the tongue with an immunohistochemical study

    Science.gov (United States)

    Pereira, Gregório Wrublevski; Pereira, Volnei David; Pereira Junior, José Antonio de Castro; da Silva, Rosemeri Maurici

    2012-01-01

    By definition, choristomas are normal tissues found in anomalous topography. The cartilaginous features of these lesions are rare in the soft tissues of the oral cavity. The majority of cartilaginous choristomas of the tongue—the primary site of emergence of the oropharynx—are associated with adipose, fibrous or bone tissues—apart from that, only a few of these were confirmed by an immunohistochemical study. The neoplasm exclusively composed of chondromatous tissue is extremely rare in the tongue. This paper reports the clinical, surgical and pathological characteristics of a cartilaginous choristoma of the tongue diagnosed in a 64-year-old woman. PMID:23220826

  16. Does Mother Tongue Interfere in Second Language Learning?

    OpenAIRE

    Denizer, Elif Nur

    2017-01-01

    Mother tongue largely refers to not only the language one learns from one’s mother but also the speaker’s dominant and home language. It’s also called native language. This study was conducted to find whether mother tongue interferences in second-language learning, and if so; whether it affects the learners’ performance in four language skills, and also in which skill(s) it has the biggest effect. Data collection tool included a questionnaire by which participants were asked to rate the quest...

  17. Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics

    Directory of Open Access Journals (Sweden)

    Emil H. Rijnbeek

    2018-05-01

    Full Text Available In this paper various types of electrodes for stimulation and recording activity of peripheral nerves for the control of neuroprosthetic limbs are reviewed. First, an overview of interface devices for (feedback- controlled movement of a prosthetic device is given, after which the focus is on peripheral nervous system (PNS electrodes. Important electrode properties, i.e., longevity and spatial resolution, are defined based upon the usability for neuroprostheses. The cuff electrode, longitudinal intrafascicular electrodes (LIFE, transverse intrafascicular multichannel electrode (TIME, Utah slanted electrode array (USEA, and the regenerative electrode are discussed and assessed on their longevity and spatial resolution. The cuff electrode seems to be a promising electrode for the control of neuroprostheses in the near future, because it shows the best longevity and good spatial resolution and it has been used on human subjects in multiple studies. The other electrodes may be promising in the future, but further research on their longevity and spatial resolution is needed. A more quantitatively uniform study protocol used for all electrodes would allow for a proper comparison of recording and stimulation performance. For example, the discussed electrodes could be compared in a large in vivo study, using one uniform comparison protocol.

  18. Using Unconstrained Tongue Motion as an Alternative Control Mechanism for Wheeled Mobility

    OpenAIRE

    Huo, Xueliang; Ghovanloo, Maysam

    2009-01-01

    Tongue drive system (TDS) is a tongue-operated, minimally invasive, unobtrusive, noncontact, and wireless assistive technology that infers users’ intentions by detecting and classifying their voluntary tongue motions, and translating them to user-defined commands. We have developed customized interface circuitry between an external TDS (eTDS) prototype and a commercial powered wheelchair (PWC) as well as three control strategies to evaluate the tongue motion as an alternative control input fo...

  19. SNP Arrays

    Directory of Open Access Journals (Sweden)

    Jari Louhelainen

    2016-10-01

    Full Text Available The papers published in this Special Issue “SNP arrays” (Single Nucleotide Polymorphism Arrays focus on several perspectives associated with arrays of this type. The range of papers vary from a case report to reviews, thereby targeting wider audiences working in this field. The research focus of SNP arrays is often human cancers but this Issue expands that focus to include areas such as rare conditions, animal breeding and bioinformatics tools. Given the limited scope, the spectrum of papers is nothing short of remarkable and even from a technical point of view these papers will contribute to the field at a general level. Three of the papers published in this Special Issue focus on the use of various SNP array approaches in the analysis of three different cancer types. Two of the papers concentrate on two very different rare conditions, applying the SNP arrays slightly differently. Finally, two other papers evaluate the use of the SNP arrays in the context of genetic analysis of livestock. The findings reported in these papers help to close gaps in the current literature and also to give guidelines for future applications of SNP arrays.

  20. Artificial control of muscle by endoneural multi electrode stimulation and sensing

    NARCIS (Netherlands)

    Rutten, Wim; Bouwman, R.L.M.

    1991-01-01

    Artificial electrical stimulation of motor nerves for muscle control can be made selective by using intrafascicular micro electrode arrays which contact many individual or small groups of nerve fibres. If at the same time te electrode arrays could record afferent information from the stimulated

  1. MnO{sub 2} nanotube and nanowire arrays by electrochemical deposition for supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Hui; Feng, Jinkui; Wang, Hailong; Lai, Man On; Lu, Li [Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117576 (Singapore)

    2010-07-01

    Highly ordered MnO{sub 2} nanotube and nanowire arrays are successfully synthesized via a electrochemical deposition technique using porous alumina templates. The morphologies and microstructures of the MnO{sub 2} nanotube and nanowire arrays are investigated by field emission scanning electron microscopy and transmission electron microscopy. Electrochemical characterization demonstrates that the MnO{sub 2} nanotube array electrode has superior capacitive behaviour to that of the MnO{sub 2} nanowire array electrode. In addition to high specific capacitance, the MnO{sub 2} nanotube array electrode also exhibits good rate capability and good cycling stability, which makes it promising candidate for supercapacitors. (author)

  2. A three-dimensional kinematic analysis of tongue flicking in Python molurus

    NARCIS (Netherlands)

    Groot, de J.H.; Sluijs, van der I.; Snelderwaard, P.C.; Leeuwen, van J.L.

    2004-01-01

    The forked snake tongue is a muscular organ without hard skeletal support. A functional interpretation of the variable arrangement of the intrinsic muscles along the tongue requires a quantitative analysis of the motion performance during tongue protrusion and flicking. Therefore, high-speed

  3. Analysis of 3-D Tongue Motion from Tagged and Cine Magnetic Resonance Images

    Science.gov (United States)

    Xing, Fangxu; Woo, Jonghye; Lee, Junghoon; Murano, Emi Z.; Stone, Maureen; Prince, Jerry L.

    2016-01-01

    Purpose: Measuring tongue deformation and internal muscle motion during speech has been a challenging task because the tongue deforms in 3 dimensions, contains interdigitated muscles, and is largely hidden within the vocal tract. In this article, a new method is proposed to analyze tagged and cine magnetic resonance images of the tongue during…

  4. Right of Knowing and Using Mother Tongue: A Mixed Method Study

    Science.gov (United States)

    Ozfidan, Burhan

    2017-01-01

    Language is a crucial factor for the academic achievement of minority people. Speaking the mother tongue in school increases self-confidence and thinking skills, and conveys freedom of speech. Mother tongue is an inseparable element of his or her culture and that everyone has the right to learn his or her mother tongue. The main objective of this…

  5. High voltage load resistor array

    Science.gov (United States)

    Lehmann, Monty Ray [Smithfield, VA

    2005-01-18

    A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

  6. Fine-needle aspiration cytology of mucous retention cyst of the tongue: distinction from other cystic lesions of the tongue.

    Science.gov (United States)

    De Las Casas, L E; Bardales, R H

    2000-05-01

    Mucous retention cyst (MRC) is a common submucosal lesion of the oral cavity that, when deeply seated, simulates a neoplasm. This report describes the fine-needle aspiration cytology findings of a lingual MRC of complex architecture and with metaplastic epithelium. In addition, we emphasize its cytologic differential diagnosis from other benign and malignant cystic lesions of the tongue. To the best of our knowledge, this is the first report of aspiration cytology of a complex MRC of the tongue. Copyright 2000 Wiley-Liss, Inc.

  7. Imprinting of molecular recognition sites combined with π-donor-acceptor interactions using bis-aniline-crosslinked Au-CdSe/ZnS nanoparticles array on electrodes: Development of electrochemiluminescence sensor for the ultrasensitive and selective detection of 2-methyl-4-chlorophenoxyacetic acid.

    Science.gov (United States)

    Yang, Yukun; Fang, Guozhen; Wang, Xiaomin; Liu, Guiyang; Wang, Shuo

    2016-03-15

    A novel strategy is reported for the fabrication of bis-aniline-crosslinked Au nanoparticles (NPs)-CdSe/ZnS quantum dots (QDs) array composite by facil one-step co-electropolymerization of thioaniline-functionalized AuNPs and thioaniline-functionalized CdSe/ZnS QDs onto thioaniline-functionalized Au elctrodes (AuE). Stable and enhanced cathodic electrochemiluminescence (ECL) of CdSe/ZnS QDs is observed on the modified electrode in neutral solution, suggesting promising applications in ECL sensing. An advanced ECL sensor is explored for detection of 2-methyl-4-chlorophenoxyacetic acid (MCPA) which quenches the ECL signal through electron-transfer pathway. The sensitive determination of MCPA with limit of detection (LOD) of 2.2 nmolL(-1) (S/N=3) is achieved by π-donor-acceptor interactions between MCPA and the bis-aniline bridging units. Impressively, the imprinting of molecular recognition sites into the bis-aniline-crosslinked AuNPs-CdSe/ZnS QDs array yields a functionalized electrode with an extremely sensitive response to MCPA in a linear range of 10 pmolL(-1)-50 μmolL(-1) with a LOD of 4.3 pmolL(-1 ()S/N=3). The proposed ECL sensor with high sensitivity, good selectivity, reproducibility and stability has been successfully applied for the determination of MCPA in real samples with satisfactory recoveries. In this study, ECL sensor combined the merits of QDs-ECL and molecularly imprinting technology is reported for the first time. The developed ECL sensor holds great promise for the fabrication of QDs-based ECL sensors with improved sensitivity and furthermore opens the door to wide applications of QDs-based ECL in food safety and environmental monitoring. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Electrodes for stochastic cooling of the FNAL antiproton source

    International Nuclear Information System (INIS)

    Voelker, F.

    1982-11-01

    AN electrode array for stochastic cooling is being developed for use on the FNAL antiproton source. With minor power handling modifications, the same electrodes can function as pickups or as kickers. When used as pickups, a large array is needed to increase the signal-to-noise ratio. Each electrode is one element of a pair of directional coupler loops that are mounted flush with the upper and lower walls of the beam chamber. The loops, fabricated from flat metal plates, are supported by specially shaped legs

  9. An automated system for the objective evaluation of human gustatory sensitivity using tongue biopotential recordings.

    Directory of Open Access Journals (Sweden)

    Danilo Pani

    Full Text Available The goal of this work is to develop an automatic system for the evaluation of the gustatory sensitivity of patients using an electrophysiological recording of the response of bud cells to taste stimuli. In particular, the study aims to evaluate the effectiveness and limitations of supervised classifiers in the discrimination between subjects belonging to the three 6-n-propylthiouracil (PROP taster categories (supertasters, medium tasters, and non-tasters, exploiting features extracted from electrophysiological recordings of the tongue. Thirty-nine subjects (equally divided into the three PROP status classes by standard non-objective scaling methods underwent a non-invasive, differential, biopotential recording of their tongues during stimulation with PROP by using a custom-made, flexible, silver electrode. Two different classifiers were trained to recognize up to seven different features extracted from the recorded depolarization signal. The classification results indicate that the identified set of features allows to distinguish between PROP tasters and non-tasters (average accuracy of 80% ± 18% and up to 94% ± 15% when only supertasters and non-tasters are considered, but medium tasters were difficult to identify. However, these apparent classification errors are related to uncertainty in the labeling procedures, which are based on non-objective tests, in which the subjects provided borderline evaluations. Thus, using the proposed method, it is possible, for the first time, to automatically achieve objective PROP taster status identification with high accuracy. The simplicity of the recording technique allows for easy reproduction of the experimental setting; thus the technique can be used in future studies to evaluate other gustatory stimuli. The proposed approach represents the first objective and automatic method to directly measure human gustatory responses and a milestone for physiological taste studies, with applications ranging from

  10. Intraneural stimulation using wire-microelectrode arrays: analysis of force steps in recruitment curves

    NARCIS (Netherlands)

    Smit, J.P.A.; Rutten, Wim; Boom, H.B.K.

    1996-01-01

    In acute experiments on six Wistar rats, a wire-microelectrode array was inserted into the common peroneal nerve. A 5-channel array and a 24-channel array were available. Each electrode in the array was used to generate a twitch contraction force recruitment curve for the extensor digitorum longus

  11. The Holy Spirit as Dove and as Tongues of Fire

    DEFF Research Database (Denmark)

    Nielsen, Kirsten

    2011-01-01

    This article analyses the dove and the tongues of fire in Jørgen Gustava Brandt's hymn "Hør himmelsus i tredie time!" (Hear the rush from heaven at the third hour!) The following intertexts are included in the analysis: Acts 2:1-4; Gen 11:1-9, examples of fire as image of God in the Old Testament...

  12. Taste profile characterization of white ginseng by electronic tongue ...

    African Journals Online (AJOL)

    Pg4) from white ginseng was checked using an electronic tongue. The bitterness and aftertaste-B of Pg3 were perceived as significantly higher than those of the other subfractions. The sourness of Pg2 had the highest rating compared to that of the other subfractions. The umami of Pg4 was higher than that of the other ...

  13. Cat Got Your Tongue? Teaching Idioms to English Learners

    Science.gov (United States)

    Mcpherron, Paul; Randolph, Patrick T.

    2014-01-01

    Why do questions about idioms often leave us "tongue-tied" in our classrooms? This book takes a look at learning and teaching idioms from two perspectives. First is a survey of recent work on learning and teaching idioms from diverse perspectives in the linguistics and educational research literature. The survey includes definitions of…

  14. How Children Learn Their Mother Tongue: They Don't

    Science.gov (United States)

    Halpern, Mark

    2016-01-01

    A new solution is offered to the Infant Language Acquisition Problem, rejecting both of Chomsky's alternatives. It proposes that the infant does not acquire his mother tongue by mastering its grammar, whether by inference from personal experience or via an innate Language Acquisition Device such as the UG, but that the language he hears is all…

  15. Mother Tongue-Based Bilingual Education in Papua New Guinea

    Science.gov (United States)

    Malone, Susan; Paraide, Patricia

    2011-01-01

    Papua New Guinea (PNG), an independent state in the southwest Pacific, is the most linguistically diverse country in the world. Its roughly six million people speak over 800 distinct languages. In spite of this diversity, in 1995 the Papua New Guinean government established a mother tongue-based bilingual education programme in which community…

  16. The challenge of mother tongue education in Kenya | Kobia | Lwati ...

    African Journals Online (AJOL)

    The importance of mother tongue in the cognitive, linguistic, personal and educational development of children cannot be overemphasised. It is out of this recognition that the UNESCO declared 2006 the Year of African Languages. In spite of this, the language policy in Kenya continues to be tilted in favour of English and to ...

  17. Mother-tongue education or bilingual education for South Africa ...

    African Journals Online (AJOL)

    Mother-tongue education or bilingual education for South Africa: theories, pedagogies and sustainability. ... academics and other stakeholders in education in South Africa. There remains a need for a population proficient ... the relationship between theory, approaches and contexts in language development in South Africa.

  18. Tapping into tongue motion to substitute or augment upper limbs

    Science.gov (United States)

    Ghovanloo, Maysam; Sahadat, M. Nazmus; Zhang, Zhenxuan; Kong, Fanpeng; Sebkhi, Nordine

    2017-05-01

    Assistive technologies (AT) play an important role in the lives of people with disabilities. Most importantly, they allow individuals with severe physical disabilities become more independence. Inherent abilities of the human tongue originated from its strong representation in the motor cortex, its direct connection to the brain through well-protected cranial nerves, and easy access without a surgery have resulted in development of a series of tongue-operated ATs that tap into the dexterous, intuitive, rapid, precise, and tireless motion of the tongue. These ATs not only help people with tetraplegia as a result of spinal cord injury or degenerative neurological diseases to access computers/smartphones, drive wheelchairs, and interact with their environments but also have the potential to enhance rehabilitation paradigms for stroke survivors. In this paper, various types of tongue operated ATs are discussed based on their working principles and task based performances. Comparisons are drawn based on widely accepted and standardized quantitative measures, such as throughput, information transfer rate, typing speed/accuracy, tracking error, navigation period, and navigation accuracy as well as qualitative measures, such as user feedback. Finally, the prospects of using variations of these versatile devices to enhance human performance in environments that limit hand and finger movements, such as space exploration or underwater operations are discussed.

  19. Mother Tongue Education in Singapore: Concerns, Issues and Controversies

    Science.gov (United States)

    Ng, Chin Leong Patrick

    2014-01-01

    In 1966, the Singapore Government implemented the English-knowing bilingual policy which made it mandatory for all Chinese students to study English as a "First Language" and the Chinese language (CL) as a "Mother Tongue Language" in Singapore schools. Using key literature relevant to Singapore's bilingual educational policy…

  20. Negotiating ironies and paradoxes of mother-tongue education: An ...

    African Journals Online (AJOL)

    In this article an introspective and retrospective overview of mother-tongue education in South Africa during the Bantu Education era (1955–c1990) is presented within the context of the discourse of learning and teaching language policies of the pre- and post-apartheid era (c1990–2014), with specific reference to literary ...

  1. Analysis of normal tongue by dynamic enhanced MRI

    International Nuclear Information System (INIS)

    Ariyoshi, Yasunori; Shimahara, Masashi

    2003-01-01

    We qualitatively evaluated dynamic enhanced MR images of normal tongues of 26 patients without oral malignancy, inflammatory diseases or systemic diseases. The selected slices were not affected by apparent artifacts including motion and susceptibility, and the tongue shape was delineated as symmetrical on coronal images, which were obtained using a T1 weighted spin echo pulse sequence (repetition time/echo time (TR/TE)=200/20). Slices at the incisor and molar levels were evaluated. Structures that could be identified on each pre-contrast image could also be identified on the post-contrast dynamic enhanced image. However, identification of the intrinsic tongue musculature was impossible on the images that were composed of symmetrical, relatively high signal areas surrounded by a low signal area. Both areas were gradually but apparently enhanced. The sublingual space was easily identified at the molar level, as it was rapidly enhanced and symmetrically delineated on each image, however, it was difficult to determine at the incisor level. Further, the lingual septum could also be identified in almost all images at the molar level, and showed no enhancement pattern, whereas, the mucosal surface of the dorsum tongue was rapidly enhanced, and identified on each image. (author)

  2. Taste profile characterization of white ginseng by electronic tongue ...

    African Journals Online (AJOL)

    GREGORY

    2012-05-10

    May 10, 2012 ... the flavor of substances such as foods and poisons. Humans perceive taste through sensory organs called taste buds concentrated on the upper tongue surface. Basic taste contributes to the sensation and flavor of foods in the mouth. Sourness is the taste that detects acidity. The sourness of substances is ...

  3. Tooth brushing, tongue cleaning and snacking behaviour of dental ...

    African Journals Online (AJOL)

    Objective: To determine the tooth brushing, tongue cleaning and snacking behaviour of dental technology and therapist students. Methods: A descriptive cross-sectional study of students of Federal School of Dental Therapy and Technology Enugu, Nigeria. Self-administered questionnaire was used to obtain information on ...

  4. Diagnostics for the Biased Electrode Experiment on NSTX

    International Nuclear Information System (INIS)

    Roquemore, A.L.; Zweben, S.J.; Bush, C.E.; Kaita, R.; Marsalsa, R.J.; Maqueda, R.J.

    2009-01-01

    A linear array of four small biased electrodes was installed in NSTX in an attempt to control the width of the scrape-off layer (SOL) by creating a strong local poloidal electric field. The set of electrodes were separated poloidally by a 1 cm gap between electrodes and were located slightly below the midplane of NSTX, 1 cm behind the RF antenna and oriented so that each electrode is facing approximately normal to the magnetic field. Each electrode can be independently biased to ± 100 volts. Present power supplies limit the current on two electrodes to 30 amps the other two to 10 amps each. The effect of local biasing was measured with a set of Langmuir probes placed between the electrodes and another set extending radially outward from the electrodes, and also by the gas puff imaging diagnostic (GPI) located 1 m away along the magnetic field lines intersecting the electrodes. Two fast cameras were also aimed directly at the electrode array. The hardware and controls of the biasing experiment will be presented and the initial effects on local plasma parameters will be discussed

  5. Using a cut-paste method to prepare a carbon nanotube fur electrode

    International Nuclear Information System (INIS)

    Zhang, H; Cao, G P; Yang, Y S

    2007-01-01

    We describe and realize an aligned carbon nanotube array based 'carbon nanotube fur (CNTF)' electrode. We removed an 800 μm long aligned carbon nanotube array from the silica substrate, and then pasted the array on a nickel foam current collector to obtain a CNTF electrode. CNTF's characteristics and electrochemical properties were studied systemically in this paper. The cut-paste method is simple, and does not damage the microstructure of the aligned carbon nanotube array. The CNTF electrode obtained a specific capacitance of 14.1 F g -1 and excellent rate capability

  6. Gingival recession is likely associated with tongue piercings.

    Science.gov (United States)

    Reynolds, Mark A

    2012-09-01

    A convenience sample of 60 subjects (27 male; 33 female) with tongue piercings (case group) and 120 subjects (43 male; 77 female) without tongue piercings (control group), ranging in age from 13 to 28 years, were identified from a mix of races living in a geographic area of low socioeconomic status in Brazil. Subjects were recruited from school groups and university centers between January 2008 and March 2009. For each case, 2 controls were selected on a consecutive basis from the same school according to criteria that included age, gender, smoking, and previous orthodontic treatment. Exclusion criteria included individuals with systemic diseases that might compromise the immune system, as well as antibiotics within 3 months or other medications that could affect the gingival tissues. The key study factor was the use or nonuse of tongue piercings (jewelry). The analysis compared periodontal parameters, such as the occurrence, location, and severity of gingival recession, in subjects with and without tongue jewelry. Gingival recession in the anterior lingual mandibular region was assessed as the primary outcome measure. The study sample was divided according to the presence or absence of gingival recession as well as the severity (1-2, 3, and ≥ 4 mm) of gingival recession. The average age of subjects was similar in the case and control groups (18.9 versus 17.7 years, respectively). Fractures of the anterior teeth were present significantly more frequently in cases than controls (26.7% versus 11.7%, respectively; P piercings (OR = 11.0, 95% confidence interval [CI] 5.02-24.09, P <.001). The severity of recession in this region was also significantly higher (calculated using an ordinal scale) in cases than in controls (P < .001). The final multivariate logistic regression model for occurrence of gingival recession included the variables tongue jewelry (yes/no), age, male gender, and the presence of bleeding on probing in the anterior region. Subjects with tongue

  7. Short faces, big tongues: developmental origin of the human chin.

    Directory of Open Access Journals (Sweden)

    Michael Coquerelle

    Full Text Available During the course of human evolution, the retraction of the face underneath the braincase, and closer to the cervical column, has reduced the horizontal dimension of the vocal tract. By contrast, the relative size of the tongue has not been reduced, implying a rearrangement of the space at the back of the vocal tract to allow breathing and swallowing. This may have left a morphological signature such as a chin (mental prominence that can potentially be interpreted in Homo. Long considered an autopomorphic trait of Homo sapiens, various extinct hominins show different forms of mental prominence. These features may be the evolutionary by-product of equivalent developmental constraints correlated with an enlarged tongue. In order to investigate developmental mechanisms related to this hypothesis, we compare modern 34 human infants against 8 chimpanzee fetuses, whom development of the mandibular symphysis passes through similar stages. The study sets out to test that the shared ontogenetic shape changes of the symphysis observed in both species are driven by the same factor--space restriction at the back of the vocal tract and the associated arrangement of the tongue and hyoid bone. We apply geometric morphometric methods to extensive three-dimensional anatomical landmarks and semilandmarks configuration, capturing the geometry of the cervico-craniofacial complex including the hyoid bone, tongue muscle and the mandible. We demonstrate that in both species, the forward displacement of the mental region derives from the arrangement of the tongue and hyoid bone, in order to cope with the relative horizontal narrowing of the oral cavity. Because humans and chimpanzees share this pattern of developmental integration, the different forms of mental prominence seen in some extinct hominids likely originate from equivalent ontogenetic constraints. Variations in this process could account for similar morphologies.

  8. Manipulators inspired by the tongue of the chameleon

    International Nuclear Information System (INIS)

    Debray, Alexis

    2011-01-01

    Chameleons have developed a specialized ballistic tongue which elongates more than six times its rest length at speeds higher than 3.5 m s -1 and accelerations 350 m s -2 , with a highly flexible mobile part, and which applies no continuous force during forward motion. These characteristics are possible because this tongue consists of two highly specialized systems, an ejection system for the forward motion and an accordion-like system for the retraction. Four manipulators inspired by the tongue of the chameleon and based on this design have been developed, resulting in three characteristics similar to the tongue of the chameleon: extensibility of the manipulator, flexibility of the mobile part, and absence of continuous force during the forward motion. The first manipulator mimics the basic mechanism of the tongue of the chameleon and reproduced its basic performances. A second manipulator performs a catching function at a speed of 3.5 m s -1 with an acceleration of 573 m s -2 while elongating seven times its rest length. The design of this manipulator is such that the dc motor used for retraction applies a torque 25 times its rated torque. Moreover, during the retraction, the mobile part of the manipulator moves due to its own inertia, allowing the dc motor to rotate at full velocity. In another manipulator, the addition of an elastomer in the mobile part allows for control of the retraction velocity. A model for these two manipulators compares well with the experimental data. Finally, the addition of wings on the mobile part allows us to take the advantage of aerodynamic effects, which is unusual for manipulators.

  9. Manipulators inspired by the tongue of the chameleon.

    Science.gov (United States)

    Debray, Alexis

    2011-06-01

    Chameleons have developed a specialized ballistic tongue which elongates more than six times its rest length at speeds higher than 3.5 m s(-1) and accelerations 350 m s(-2), with a highly flexible mobile part, and which applies no continuous force during forward motion. These characteristics are possible because this tongue consists of two highly specialized systems, an ejection system for the forward motion and an accordion-like system for the retraction. Four manipulators inspired by the tongue of the chameleon and based on this design have been developed, resulting in three characteristics similar to the tongue of the chameleon: extensibility of the manipulator, flexibility of the mobile part, and absence of continuous force during the forward motion. The first manipulator mimics the basic mechanism of the tongue of the chameleon and reproduced its basic performances. A second manipulator performs a catching function at a speed of 3.5 m s(-1) with an acceleration of 573 m s(-2) while elongating seven times its rest length. The design of this manipulator is such that the dc motor used for retraction applies a torque 25 times its rated torque. Moreover, during the retraction, the mobile part of the manipulator moves due to its own inertia, allowing the dc motor to rotate at full velocity. In another manipulator, the addition of an elastomer in the mobile part allows for control of the retraction velocity. A model for these two manipulators compares well with the experimental data. Finally, the addition of wings on the mobile part allows us to take the advantage of aerodynamic effects, which is unusual for manipulators.

  10. Manipulators inspired by the tongue of the chameleon

    Energy Technology Data Exchange (ETDEWEB)

    Debray, Alexis, E-mail: debray.alexis@canon.co.jp [Canon Incorporation, 3-30-2, Shimomaruko, Ohta-ku, Tokyo 146-8501 (Japan)

    2011-06-15

    Chameleons have developed a specialized ballistic tongue which elongates more than six times its rest length at speeds higher than 3.5 m s{sup -1} and accelerations 350 m s{sup -2}, with a highly flexible mobile part, and which applies no continuous force during forward motion. These characteristics are possible because this tongue consists of two highly specialized systems, an ejection system for the forward motion and an accordion-like system for the retraction. Four manipulators inspired by the tongue of the chameleon and based on this design have been developed, resulting in three characteristics similar to the tongue of the chameleon: extensibility of the manipulator, flexibility of the mobile part, and absence of continuous force during the forward motion. The first manipulator mimics the basic mechanism of the tongue of the chameleon and reproduced its basic performances. A second manipulator performs a catching function at a speed of 3.5 m s{sup -1} with an acceleration of 573 m s{sup -2} while elongating seven times its rest length. The design of this manipulator is such that the dc motor used for retraction applies a torque 25 times its rated torque. Moreover, during the retraction, the mobile part of the manipulator moves due to its own inertia, allowing the dc motor to rotate at full velocity. In another manipulator, the addition of an elastomer in the mobile part allows for control of the retraction velocity. A model for these two manipulators compares well with the experimental data. Finally, the addition of wings on the mobile part allows us to take the advantage of aerodynamic effects, which is unusual for manipulators.

  11. The Tip-of-the-Tongue Heuristic: How Tip-of-the-Tongue States Confer Perceptibility on Inaccessible Words

    Science.gov (United States)

    Cleary, Anne M.; Claxton, Alexander B.

    2015-01-01

    This study shows that the presence of a tip-of-the-tongue (TOT) state--the sense that a word is in memory when its retrieval fails--is used as a heuristic for inferring that an inaccessible word has characteristics that are consistent with greater word perceptibility. When reporting a TOT state, people judged an unretrieved word as more likely to…

  12. Rational design of new electrodes for electrochemotherapy.

    Science.gov (United States)

    Spugnini, E P; Citro, G; Porrello, A

    2005-06-01

    Electrochemotherapy associates the local delivery of anticancer drugs with the administration of permeabilizing electric pulses that support the antiblastic action. The basic instrumentation for this therapy is constituted by a pulse generator and various specific electrodes. While many efforts have been profuse by researchers in this field to obtain the standardization of the pulse generating equipment over the past 15 years, the delivery apparatus still needs refinements in order to reach most of the body districts, to control the homogeneity and stability of the electric fields and to further reduce morbidity. With the aim to develop innovative electrodes able to satisfy, at least partially, these requirements, extensive studies on pet patients with spontaneous neoplasms have been conducted, leading to the manufacturing of several different prototypes. In this paper we discuss the rationale of 11 different electrodes, briefly summarize the results obtained and their experimental validation, also presenting five paradigmatic clinical cases. In particular, it is shown that the caliper electrodes are more suited for the treatment of cutaneous and subcutaneous lesions, while the needle arrays are more efficacious in intraoperative settings. Furthermore, relevant peculiarities of unipolar electrodes are examined with a particular focus on the irregular current paths that they produce and on the potentialities of this feature. Remarkably, the decrease of the steric encumbrance turned out to be a stronger factor in electrode design than the containment of the total number of electric fields covered in serial ECT sessions. In the conclusions, perspectives and new challenges of electrode design for electrochemotherapy are illustrated.

  13. Electrostatic quadrupole array for focusing parallel beams of charged particles

    International Nuclear Information System (INIS)

    Brodowski, J.

    1982-01-01

    An array of electrostatic quadrupoles, capable of providing strong electrostatic focusing simultaneously on multiple beams, is easily fabricated from a single array element comprising a support rod and multiple electrodes spaced at intervals along the rod. The rods are secured to four terminals which are isolated by only four insulators. This structure requires bias voltage to be supplied to only two terminals and eliminates the need for individual electrode bias and insulators, as well as increases life by eliminating beam plating of insulators

  14. Research on Techniques of Multifeatures Extraction for Tongue Image and Its Application in Retrieval

    Directory of Open Access Journals (Sweden)

    Liyan Chen

    2017-01-01

    Full Text Available Tongue diagnosis is one of the important methods in the Chinese traditional medicine. Doctors can judge the disease’s situation by observing patient’s tongue color and texture. This paper presents a novel approach to extract color and texture features of tongue images. First, we use improved GLA (Generalized Lloyd Algorithm to extract the main color of tongue image. Considering that the color feature cannot fully express tongue image information, the paper analyzes tongue edge’s texture features and proposes an algorithm to extract them. Then, we integrate the two features in retrieval by different weight. Experimental results show that the proposed method can improve the detection rate of lesion in tongue image relative to single feature retrieval.

  15. Silver Nanowire Arrays : Fabrication and Applications

    OpenAIRE

    Feng, Yuyi

    2016-01-01

    Nanowire arrays have increasingly received attention for their use in a variety of applications such as surface-enhanced Raman scattering (SERS), plasmonic sensing, and electrodes for photoelectric devices. However, until now, large scale fabrication of device-suitable metallic nanowire arrays on supporting substrates has seen very limited success. This thesis describes my work rst on the development of a novel successful processing route for the fabrication of uniform noble metallic (e.g. A...

  16. Automated electronic tongue based on potentiometric sensors for the determination of a trinary anionic surfactant mixture.

    Science.gov (United States)

    Cortina, Montserrat; Ecker, Christina; Calvo, Daniel; del Valle, Manuel

    2008-01-22

    An automated electronic tongue consisting of an array of potentiometric sensors and an artificial neural network (ANN) has been developed to resolve mixtures of anionic surfactants. The sensor array was formed by five different flow-through sensors for anionic surfactants, based on poly(vinyl chloride) membranes having cross-sensitivity features. Feedforward multilayer neural networks were used to predict surfactant concentrations. As a great amount of information is required for the correct modelling of the sensors response, a sequential injection analysis (SIA) system was used to automatically provide it. Dodecylsulfate (DS(-)), dodecylbenzenesulfonate (DBS(-)) and alpha-alkene sulfonate (ALF(-)) formed the three-analyte study case resolved in this work. Their concentrations varied from 0.2 to 4mM for ALF(-) and DBS(-) and from 0.2 to 5mM for DS(-). Good prediction ability was obtained with correlation coefficients better than 0.933 when the obtained values were compared with those expected for a set of 16 external test samples not used for training.

  17. Determination of total polyphenol index in wines employing a voltammetric electronic tongue

    International Nuclear Information System (INIS)

    Cetó, Xavier; Gutiérrez, Juan Manuel; Gutiérrez, Manuel; Céspedes, Francisco; Capdevila, Josefina; Mínguez, Santiago; Jiménez-Jorquera, Cecilia; Valle, Manel del

    2012-01-01

    Highlights: ► Array of voltammetric sensors modified with nanoparticles or conducting polymers. ► It has been applied in wine analysis to predict polyphenol content index. ► Uses data processing tools such as discrete wavelet transform and artificial neural network. ► Identification of phenolics like gallic acid, catechin, caffeic acid, catechol. ► Predicted polyphenol index agrees with Folin–Ciocalteau method and I 280 index. - Abstract: This work reports the application of a voltammetric electronic tongue system (ET) made from an array of modified graphite-epoxy composites plus a gold microelectrode in the qualitative and quantitative analysis of polyphenols found in wine. Wine samples were analyzed using cyclic voltammetry without any sample pretreatment. The obtained responses were preprocessed employing discrete wavelet transform (DWT) in order to compress and extract significant features from the voltammetric signals, and the obtained approximation coefficients fed a multivariate calibration method (artificial neural network-ANN-or partial least squares-PLS-) which accomplished the quantification of total polyphenol content. External test subset samples results were compared with the ones obtained with the Folin–Ciocalteu (FC) method and UV absorbance polyphenol index (I 280 ) as reference values, with highly significant correlation coefficients of 0.979 and 0.963 in the range from 50 to 2400 mg L −1 gallic acid equivalents, respectively. In a separate experiment, qualitative discrimination of different polyphenols found in wine was also assessed by principal component analysis (PCA).

  18. A Low-Power Wearable Stand-Alone Tongue Drive System for People With Severe Disabilities.

    Science.gov (United States)

    Jafari, Ali; Buswell, Nathanael; Ghovanloo, Maysam; Mohsenin, Tinoosh

    2018-02-01

    This paper presents a low-power stand-alone tongue drive system (sTDS) used for individuals with severe disabilities to potentially control their environment such as computer, smartphone, and wheelchair using their voluntary tongue movements. A low-power local processor is proposed, which can perform signal processing to convert raw magnetic sensor signals to user-defined commands, on the sTDS wearable headset, rather than sending all raw data out to a PC or smartphone. The proposed sTDS significantly reduces the transmitter power consumption and subsequently increases the battery life. Assuming the sTDS user issues one command every 20 ms, the proposed local processor reduces the data volume that needs to be wirelessly transmitted by a factor of 64, from 9.6 to 0.15 kb/s. The proposed processor consists of three main blocks: serial peripheral interface bus for receiving raw data from magnetic sensors, external magnetic interference attenuation to attenuate external magnetic field from the raw magnetic signal, and a machine learning classifier for command detection. A proof-of-concept prototype sTDS has been implemented with a low-power IGLOO-nano field programmable gate array (FPGA), bluetooth low energy, battery and magnetic sensors on a headset, and tested. At clock frequency of 20 MHz, the processor takes 6.6 s and consumes 27 nJ for detecting a command with a detection accuracy of 96.9%. To further reduce power consumption, an application-specified integrated circuit processor for the sTDS is implemented at the postlayout level in 65-nm CMOS technology with 1-V power supply, and it consumes 0.43 mW, which is 10 lower than FPGA power consumption and occupies an area of only 0.016 mm.

  19. Morphology of the tongue of the emu (Dromaius novaehollandiae. II. Histological features

    Directory of Open Access Journals (Sweden)

    M.R. Crole

    2009-09-01

    Full Text Available Although a number of brief, fragmented descriptions have been provided on the gross morphology of the ratite tongue, very few studies have documented the histological structure of this organ. This paper presents the first definitive histological description of the emu tongue and reviews, consolidates and compares the scattered information on the histology of the ratite tongue available in the literature. Five tongues were removed from heads obtained from birds at slaughter and fixed in 10 % neutral buffered formalin. Appropriate longitudinal and transverse segments were removed, routinely processed for light microscopy, and sections examined after staining with H & E and PAS. The entire tongue (body and root is invested by a non-keratinized stratified squamous epithelium. The supporting connective tissue of the tongue dorsum displays only large, simple branched tubular mucussecreting glands, whereas the caudal tongue body ventrum and tongue root, in addition to these glands, also exhibits small, simple tubular mucus-secreting glands. Herbst corpuscles are associated with the large, simple branched glands. Lymphoid tissue is restricted to the tongue ventrum and is particularly obvious at the junction of the ventral tongue body and frenulum where a large aggregation of diffuse lymphoid tissue, with nodular tissue proximally, was consistently observed. A structure resembling a taste bud was located in the epithelium on the caudal extremity of the tongue root of one bird. This is the first reported observation of taste buds in ratites. Forming the core of the tongue body is the cartilaginous paraglossum lying dorsal to the partially ossified rostral projection of the basihyale. The histological features of the emu tongue are generally similar to those described for the greater rhea and ostrich, except that taste buds were not identified in these species. The results would suggest that the emu tongue functions as a sensory organ, both for taste and

  20. Filter arrays

    Science.gov (United States)

    Page, Ralph H.; Doty, Patrick F.

    2017-08-01

    The various technologies presented herein relate to a tiled filter array that can be used in connection with performance of spatial sampling of optical signals. The filter array comprises filter tiles, wherein a first plurality of filter tiles are formed from a first material, the first material being configured such that only photons having wavelengths in a first wavelength band pass therethrough. A second plurality of filter tiles is formed from a second material, the second material being configured such that only photons having wavelengths in a second wavelength band pass therethrough. The first plurality of filter tiles and the second plurality of filter tiles can be interspersed to form the filter array comprising an alternating arrangement of first filter tiles and second filter tiles.

  1. A compact electron gun using field emitter array

    International Nuclear Information System (INIS)

    Asakawa, M.R.; Ikeda, A.; Miyabe, N.; Yamaguchi, S.; Kusaba, M.; Tsunawaki, Y.

    2008-01-01

    A compact electron gun using field emitter array has been developed. With a simple triode configuration consisting of FEA, mid-electrode and anode electrode, the electron gun produces a parallel beam with a diameter of 0.5 mm. This electron gun is applicable for compact radiation sources such as Cherenkov free-electron lasers

  2. Pitch ranking, electrode discrimination, and physiological spread-of-excitation using Cochlear's dual-electrode mode.

    Science.gov (United States)

    Goehring, Jenny L; Neff, Donna L; Baudhuin, Jacquelyn L; Hughes, Michelle L

    2014-08-01

    This study compared pitch ranking, electrode discrimination, and electrically evoked compound action potential (ECAP) spatial excitation patterns for adjacent physical electrodes (PEs) and the corresponding dual electrodes (DEs) for newer-generation Cochlear devices (Cochlear Ltd., Macquarie, New South Wales, Australia). The first goal was to determine whether pitch ranking and electrode discrimination yield similar outcomes for PEs and DEs. The second goal was to determine if the amount of spatial separation among ECAP excitation patterns (separation index, Σ) between adjacent PEs and the PE-DE pairs can predict performance on the psychophysical tasks. Using non-adaptive procedures, 13 subjects completed pitch ranking and electrode discrimination for adjacent PEs and the corresponding PE-DE pairs (DE versus each flanking PE) from the basal, middle, and apical electrode regions. Analysis of d' scores indicated that pitch-ranking and electrode-discrimination scores were not significantly different, but rather produced similar levels of performance. As expected, accuracy was significantly better for the PE-PE comparison than either PE-DE comparison. Correlations of the psychophysical versus ECAP Σ measures were positive; however, not all test/region correlations were significant across the array. Thus, the ECAP separation index is not sensitive enough to predict performance on behavioral tasks of pitch ranking or electrode discrimination for adjacent PEs or corresponding DEs.

  3. High performance cermet electrodes

    Science.gov (United States)

    Isenberg, Arnold O.; Zymboly, Gregory E.

    1986-01-01

    Disclosed is a method of increasing the operating cell voltage of a solid oxide electrochemical cell having metal electrode particles in contact with an oxygen-transporting ceramic electrolyte. The metal electrode is heated with the cell, and oxygen is passed through the oxygen-transporting ceramic electrolyte to the surface of the metal electrode particles so that the metal electrode particles are oxidized to form a metal oxide layer between the metal electrode particles and the electrolyte. The metal oxide layer is then reduced to form porous metal between the metal electrode particles and the ceramic electrolyte.

  4. Free flap transfer reconstruction in managing tongue carcinoma during pregnancy.

    Science.gov (United States)

    Miyazaki, Yuko; Fukuda, Kenji; Fujita, Kazutoshi; Nishimoto, Soh; Terada, Tomonori; Wada, Ryu; Sotsuka, Yohei; Kawai, Kenichiro; Kakibuchi, Masao

    2017-08-01

    Malignant oral cancers do not commonly occur in pregnant women. But when they do, the presence of a foetus and maternal physiological changes complicate and limit the treatment options. Risk benefit assessment and balancing of them are always important. A 33-year-old woman, who was 25 weeks pregnant, presented with a squamous cell carcinoma on her tongue. She was clinically staged II (T2, N0 and M0). Discussions between the patient, surgical teams and obstetricians agreed to continue her pregnancy while managing the tumour. Hemi-glossectomy and ipsilateral neck dissection was performed. Free antero-lateral thigh flap was transferred to reconstruct the tongue defect, successfully. The patient gave birth to a healthy baby afterward. She is tumour free for 6 years. Free flap reconstruction can be an option, even if the patient is pregnant.

  5. Mother Tongue Tuition in Sweden - Curriculum Analysis and Classroom Experience

    Directory of Open Access Journals (Sweden)

    Anne REATH WARREN

    2013-10-01

    Full Text Available The model of Mother Tongue Tuition (MTT which has developed in Sweden since the 1970’s offers speakers of languages other than Swedish the opportunity to request tuition in their mother tongue, from kindergarten through to year 12. It is unique among the major immigrant-receiving countries of the world yet little is known about MTT and its syllabus outside of its Nordic context. This article examines the syllabus for MTT from two perspectives; firstly using the framework of Constructive Alignment, secondly from the perspective of what is hidden. The intended syllabus is revealed as well-aligned, but the hidden curriculum impedes successful enactment in many contexts. Examples from case studies in a larger on-going research project offer an alternate approach to syllabus implementation when the negative effects of the hidden curriculum are challenged. While highly context-specific, this model may represent a step in the right direction for implementation of the syllabus.

  6. Giant Cell Fibroma of the Tongue: A Case Report

    Directory of Open Access Journals (Sweden)

    Farrokh Farhadi

    2014-11-01

    Full Text Available Giant cell fibroma of the tongue is a rare benign fibrous tumor of connective tissues in the oral cavity, very few of which have been reported. This benign neoplasm has a predilection for the gingiva and .usually occurs in women under 30. Since this tumor is clinically, and especially histopathologically, placed in the differential diagnosis list of benign and malignant mesenchymal tumors, its proper diagnosis is of great significance because widespread and unnecessary surgeries are avoided as a result. The aim of the present report is to present a case of the tumor in the tongue of a 65-year-old man. The fibroma is a benign fibrous tumor of connective tissues which is microscopically classified in differential diagnosis with other soft tissue tumors since its proper diagnosis prevents from extensive and unnecessary surgeries on the patient.

  7. A custom-made mouthpiece incorporating tongue depressors and elevators to reduce radiation-induced tongue mucositis during carbon-ion radiation therapy for head and neck cancer.

    Science.gov (United States)

    Ikawa, Hiroaki; Koto, Masashi; Ebner, Daniel K; Takagi, Ryo; Hayashi, Kazuhiko; Tsuji, Hiroshi; Kamada, Tadashi

    We introduce a custom-made mouthpiece for carbon-ion radiation therapy for head and neck malignancy. The mouthpiece incorporates either a tongue depressor or elevator depending on tumor location. The risk of tongue mucositis may be reduced without compromising therapeutic efficacy through mouthpiece shaping. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  8. The Classification of Tongue Colors with Standardized Acquisition and ICC Profile Correction in Traditional Chinese Medicine.

    Science.gov (United States)

    Qi, Zhen; Tu, Li-Ping; Chen, Jing-Bo; Hu, Xiao-Juan; Xu, Jia-Tuo; Zhang, Zhi-Feng

    2016-01-01

    Background and Goal . The application of digital image processing techniques and machine learning methods in tongue image classification in Traditional Chinese Medicine (TCM) has been widely studied nowadays. However, it is difficult for the outcomes to generalize because of lack of color reproducibility and image standardization. Our study aims at the exploration of tongue colors classification with a standardized tongue image acquisition process and color correction. Methods . Three traditional Chinese medical experts are chosen to identify the selected tongue pictures taken by the TDA-1 tongue imaging device in TIFF format through ICC profile correction. Then we compare the mean value of L * a * b * of different tongue colors and evaluate the effect of the tongue color classification by machine learning methods. Results . The L * a * b * values of the five tongue colors are statistically different. Random forest method has a better performance than SVM in classification. SMOTE algorithm can increase classification accuracy by solving the imbalance of the varied color samples. Conclusions . At the premise of standardized tongue acquisition and color reproduction, preliminary objectification of tongue color classification in Traditional Chinese Medicine (TCM) is feasible.

  9. A Randomized Trial Comparing Two Tongue-Pressure Resistance Training Protocols for Post-Stroke Dysphagia.

    Science.gov (United States)

    Steele, Catriona M; Bayley, Mark T; Peladeau-Pigeon, Melanie; Nagy, Ahmed; Namasivayam, Ashwini M; Stokely, Shauna L; Wolkin, Talia

    2016-06-01

    The objective of this study was to compare the outcomes of two tongue resistance training protocols. One protocol ("tongue-pressure profile training") emphasized the pressure-timing patterns that are typically seen in healthy swallows by focusing on gradual pressure release and saliva swallowing tasks. The second protocol ("tongue-pressure strength and accuracy training") emphasized strength and accuracy in tongue-palate pressure generation and did not include swallowing tasks. A prospective, randomized, parallel allocation trial was conducted. Of 26 participants who were screened for eligibility, 14 received up to 24 sessions of treatment. Outcome measures of posterior tongue strength, oral bolus control, penetration-aspiration and vallecular residue were made based on videofluoroscopy analysis by blinded raters. Complete data were available for 11 participants. Significant improvements were seen in tongue strength and post-swallow vallecular residue with thin liquids, regardless of treatment condition. Stage transition duration (a measure of the duration of the bolus presence in the pharynx prior to swallow initiation, which had been chosen to capture impairments in oral bolus control) showed no significant differences. Similarly, significant improvements were not seen in median scores on the penetration-aspiration scale. This trial suggests that tongue strength can be improved with resistance training for individuals with tongue weakness following stroke. We conclude that improved penetration-aspiration does not necessarily accompany improvements in tongue strength; however, tongue-pressure resistance training does appear to be effective for reducing thin liquid vallecular residue.

  10. Relationship between dynamic infrared thermal images and blood perfusion rate of the tongue in anaemia patients

    Science.gov (United States)

    Xie, Haiwei; Zhang, Yan

    2018-03-01

    The relationship between dynamic infrared (IR) thermal images and blood perfusion rate of the tongues of anaemia patients was investigated. Blood perfusion rates at multiple locations on the tongues of 62 anaemia patients and 70 control subjects were measured. For both groups of subjects, dynamic IR thermal images were also recorded within 16 s after the mouth opened. The results showed that the blood perfusion rates at different sites (apex, middle, left side and right side) on the tongues in anaemia patients (3.49, 3.71, 3.85 and 3.77 kg/s m-3) were significantly lower than those at the corresponding sites in control subjects (4.45, 4.66, 4.81 and 4.70 kg/s m-3). After the mouth opened, the tongue temperature decreased more rapidly in anaemia patients than in control subjects. To analyse the heat transfer mechanism, a transient heat transfer model of the tongue was developed. The tongue temperatures in anaemia patients and control subjects were calculated using this model and compared to the tongue temperatures measured by the IR thermal imager. The relationship between the tongue surface temperature and the tongue blood perfusion rate was analysed. The simulation results indicated that the low blood perfusion rate and the correlated changes in anaemia patients can cause faster temperature decreases of the tongue surface.

  11. Diagnostic Method of Diabetes Based on Support Vector Machine and Tongue Images

    Directory of Open Access Journals (Sweden)

    Jianfeng Zhang

    2017-01-01

    Full Text Available Objective. The purpose of this research is to develop a diagnostic method of diabetes based on standardized tongue image using support vector machine (SVM. Methods. Tongue images of 296 diabetic subjects and 531 nondiabetic subjects were collected by the TDA-1 digital tongue instrument. Tongue body and tongue coating were separated by the division-merging method and chrominance-threshold method. With extracted color and texture features of the tongue image as input variables, the diagnostic model of diabetes with SVM was trained. After optimizing the combination of SVM kernel parameters and input variables, the influences of the combinations on the model were analyzed. Results. After normalizing parameters of tongue images, the accuracy rate of diabetes predication was increased from 77.83% to 78.77%. The accuracy rate and area under curve (AUC were not reduced after reducing the dimensions of tongue features with principal component analysis (PCA, while substantially saving the training time. During the training for selecting SVM parameters by genetic algorithm (GA, the accuracy rate of cross-validation was grown from 72% or so to 83.06%. Finally, we compare with several state-of-the-art algorithms, and experimental results show that our algorithm has the best predictive accuracy. Conclusions. The diagnostic method of diabetes on the basis of tongue images in Traditional Chinese Medicine (TCM is of great value, indicating the feasibility of digitalized tongue diagnosis.

  12. Involvement of peripheral artemin signaling in tongue pain: possible mechanism in burning mouth syndrome.

    Science.gov (United States)

    Shinoda, Masamichi; Takeda, Mamoru; Honda, Kuniya; Maruno, Mitsuru; Katagiri, Ayano; Satoh-Kuriwada, Shizuko; Shoji, Noriaki; Tsuchiya, Masahiro; Iwata, Koichi

    2015-12-01

    Burning mouth syndrome is characterized by altered sensory qualities, namely tongue pain hypersensitivity. We found that the mRNA expression of Artemin (Artn) in the tongue mucosa of patients with burning mouth syndrome was significantly higher than that of control subjects, and we developed a mouse model of burning mouth syndrome by application of 2,4,6-trinitrobenzene sulfonic acid (TNBS) diluted with 50% ethanol to the dorsum of the tongue. TNBS treatment to the tongue induced persistent, week-long, noninflammatory tongue pain and a significant increase in Artn expression in the tongue mucosa and marked tongue heat hyperalgesia. Following TNBS treatment, the successive administration of the transient receptor potential vanilloid 1 (TRPV1) antagonist SB366791 or neutralizing anti-Artn antibody completely inhibited the heat hyperalgesia. The number of glial cell line-derived neurotrophic factor family receptor α3 (GFRα3)-positive and TRPV1-positive trigeminal ganglion (TG) neurons innervating the tongue significantly increased following TNBS treatment and was significantly reduced by successive administration of neutralizing anti-Artn antibody. The capsaicin-induced current in TG neurons innervating the tongue was enhanced following TNBS treatment and was inhibited by local administration of neutralizing anti-Artn antibody to the tongue. These results suggest that the overexpression of Artn in the TNBS-treated tongue increases the membrane excitability of TG neurons innervating the tongue by increasing TRPV1 sensitivity, which causes heat hyperalgesia. This model may be useful for the study of tongue pain hypersensitivity associated with burning mouth syndrome.

  13. Overview of complications secondary to tongue and lip piercings.

    Science.gov (United States)

    Maheu-Robert, Léo-François; Andrian, Elisoa; Grenier, Daniel

    2009-07-01

    In recent years, intraoral and perioral piercings have grown in popularity among teenagers and young adults. This is of concern to dental and medical professionals because of the risks and complications for oral, dental and general health. The risks and complications associated with tongue and lip piercings range from abnormal tooth wear and cracked tooth syndrome to gingival recession and systemic infections. In this report, we provide an overview of possible problems associated with oral piercings that may be encountered by dentists.

  14. Brachytherapy for elderly patients with stage II tongue cancer

    International Nuclear Information System (INIS)

    Kimura, Tomoki; Hirokawa, Yutaka; Fujita, Minoru; Murakami, Yuji; Kenjo, Masahiro; Kaneyasu, Yuko; Ito, Katsuhide

    2003-01-01

    In treatment choices of stage II (T2N0M0) tongue cancer, brachytherapy is less invasive and superior in function preservation, therefore its role is more important in elderly patients. The aim of this study was to evaluate treatment results and morbidity of brachytherapy for elderly patients with stage II tongue cancer. Between 1980 and 2001, 198 patients with stage II tongue cancer were treated with brachytherapy at Hiroshima University Hospital. Patient ages ranged from 21 to 89 years old (median: 62 years old). Patients were divided into three groups as follows: 119 patients younger than 65 years old (Non-Elderly group), 53 patients between 65 and 75 years old (Junior Elderly group), and 26 patients 75 years or older (Senior Elderly group). Radiotherapy was performed in 101 patients with brachytherapy alone, and in 97 patients with brachytherapy and external radiotherapy. Chemotherapy was also performed in 77 patients. Follow-up period ranged from 4 to 243 months (median: 55 months). The 5-year local control rate was 85% in the Non-Elderly group, 85% in the Junior Elderly group and 81% in the Senior Elderly group. There was no significant difference among these groups. The 5-year cause-specific survival rate was 85%, 81% and 70% respectively. The Senior Elderly group showed poorer cause-specific survival rate than the other two groups (p=0.03). There was also a tendency of higher incidence of neck metastasis and low salvage rate by neck dissection in the Senior Elderly group. Although the Senior Elderly group showed poorer cause-specific survival rate, the local control rate was similar to those of the other two groups. Brachytherapy is an effective treatment option for elderly patients with stage II tongue cancer. (author)

  15. Fissured and geographic tongue in Williams-Beuren syndrome

    Directory of Open Access Journals (Sweden)

    Neeta Sharma

    2014-01-01

    Full Text Available Williams-Beuren Syndrome (WBS is a rare, most often sporadic, genetic disease caused by a chromosomal microdeletion at locus 7q11.23 involving 28 genes. It is characterized by congenital heart defects, neonatal hypercalcemia, skeletal and renal abnormalities, cognitive disorder, social personality disorder, and dysmorphic facies. A number of clinical findings has been reported, but none of the studies evaluated this syndrome considering oral cavity. We here report a fissured and geographic tongue in association with WBS.

  16. Microneedle Array Interface to CE on Chip

    NARCIS (Netherlands)

    Lüttge, Regina; Gardeniers, Johannes G.E.; Vrouwe, E.X.; van den Berg, Albert; Northrup, M.A.; Jensen, K.F; Harrison, D.J.

    2003-01-01

    This paper presents a microneedle array sampler interfaced to a capillary electrophoresis (CE) glass chip with integrated conductivity detection electrodes. A solution of alkali ions was electrokinetically loaded through the microneedles onto the chip and separation was demonstrated compared to a

  17. Clinical study on N0-stage tongue cancer

    International Nuclear Information System (INIS)

    Maruoka, Yasubumi; Ando, Tomohiro; Hoshino, Makoto; Sangu, Yoshikuni; Ogiuchi, Hideki

    2003-01-01

    We retrospectively analyzed the cases of N0-stage tongue cancer patients treated at the Department of Oral Maxillofacial Surgery, Tokyo Women's Medical University Hospital, between January 1980 and December 2000. Primary tongue cancers were treated by surgery (52%) and radiotherapy (48%). In principle, we did not perform elective neck dissection for N0-stage necks. Instead, a policy of careful observation was adopted for the management of N0-stage necks in patients with tongue cancer, and a radical neck dissection or modified radical neck dissection was performed in the event of a secondary neck metastasis. A local recurrence was confirmed in 25 patients. Twenty of the 25 local recurrences were successfully controlled by a therapy. The incidence of secondary neck metastasis was 4/46 (8%) for T1 patients, 21/48 (45%) for T2 patients, and 9/15 (60%) for T3/T4 patients. Overall, secondary neck metastases occurred in 34 out of 109 (32%) patients, and eventually 12 patients died from uncontrolled tumors. As for the distribution of involved lymph nodes, level I to level III nodes were involved in 30 (88%) patients, and level IV nodes were involved in 4 patients. (author)

  18. Visual feedback of tongue movement for novel speech sound learning

    Directory of Open Access Journals (Sweden)

    William F Katz

    2015-11-01

    Full Text Available Pronunciation training studies have yielded important information concerning the processing of audiovisual (AV information. Second language (L2 learners show increased reliance on bottom-up, multimodal input for speech perception (compared to monolingual individuals. However, little is known about the role of viewing one’s own speech articulation processes during speech training. The current study investigated whether real-time, visual feedback for tongue movement can improve a speaker’s learning of non-native speech sounds. An interactive 3D tongue visualization system based on electromagnetic articulography (EMA was used in a speech training experiment. Native speakers of American English produced a novel speech sound (/ɖ̠/; a voiced, coronal, palatal stop before, during, and after trials in which they viewed their own speech movements using the 3D model. Talkers’ productions were evaluated using kinematic (tongue-tip spatial positioning and acoustic (burst spectra measures. The results indicated a rapid gain in accuracy associated with visual feedback training. The findings are discussed with respect to neural models for multimodal speech processing.

  19. PEDICLE TONGUE FLAP SURGERY IN ORAL SUBMUCOUS FIBROSIS

    Directory of Open Access Journals (Sweden)

    Muthubabu K

    2016-09-01

    Full Text Available BACKGROUND Oral submucous fibrosis is a disease of unknown aetiology and is a legacy of Indians. It has been variously treated both medically and surgically but neither has been found to be rewarding. Various groups have been studying the therapy schedules and aetiological association, but the conclusions have remained unclear. AIM The study aims to focus on newer surgical therapy stressing on the mechanics and use of pedicle tongue flap in the management of this condition. METHODS AND MATERIALS The study comprised of 40 patients from our outpatient department suffering from oral submucous fibrosis in the age group of 11 to 70 years. The contributory factors of oral submucous fibrosis and the symptoms of the disease were evaluated and the role of pedicle tongue flap surgery in the management of this disease which is a premalignant condition is discussed. RESULTS AND CONCLUSION Pedicle tongue flap surgery has given promising results in the treatment of trismus due to oral submucous fibrosis. After the surgery, none of our patients developed any malignant change.

  20. Californium-252 interstitial implants in carcinoma of the tongue

    International Nuclear Information System (INIS)

    Vtyurin, B.M.; Ivanov, V.N.; Medvedev, V.S.; Galantseva, G.F.; Abdulkadyrov, S.A.; Ivanova, L.F.; Petrovskaya, G.A.; Plichko, V.I.

    1985-01-01

    A clinical study using 252 Cf sources in brachytherapy of tumors began in the Research Institute of Medical Radiology of the Academy of Medical Sciences of the USSR in 1973. 252 Cf afterloading cells were utilized by the method of simple afterloading. Dosimetry and radiation protection of medical personnel were developed. To substantiate optimal therapeutic doses of 252 Cf neutrons, a correlation of dose, time, and treatment volume factors with clinical results of 252 Cf interstitial implants in carcinoma of the tongue for 47 patients with a minimum follow-up period of 1 year was studied. Forty-nine interstitial implants have been performed. Seventeen patients received 252 Cf implants alone (Group I), 17 other patients received 252 Cf implants in combination with external radiation (Group II), and 15 patients were treated with interstitial implants for recurrent or residual tumors (Groups III). Complete regression of carcinoma of the tongue was obtained in 48 patients (98%). Thirteen patients (27%) developed radiation necrosis. The therapeutic dose of neutron radiation from 252 Cf sources in interstitial radiotherapy of primary tongue carcinomas (Group I) was found to be 7 to 9 Gy. Optimal therapeutic neutron dose in combined interstitial and external radiotherapy of primary tumors (Group II) was 5 to 6 Gy with an external radiation dose of 40 Gy. For recurrent and residual tumors (Group III), favorable results were obtained with tumor doses of 6.5 to 7 Gy