Sample records for tomotherapy intensity-modulated radiation

  1. Treatment of folliculitis decalvans using intensity-modulated radiation via tomotherapy

    International Nuclear Information System (INIS)

    Elsayad, Khaled; Kriz, Jan; Haverkamp, Uwe; Eich, Hans Theodor; Plachouri, Kerasia-Maria; Jeskowiak, Antonia; Sunderkoetter, Cord

    2015-01-01

    Folliculitis decalvans (FD) is a form of primary neutrophilic scarring alopecia that is characterized clinically by chronic suppurative folliculitis and often associated with pruritus or even pain. Treatment of FD is often difficult. Herein, we report a case of recalcitrant and painful folliculitis decalvans refractory to antibiotic and anti-inflammatory therapies, which was successfully treated by intensity-modulated radiotherapy (IMRT) in order to irreversibly eliminate hair follicles that prove to be one etiological trigger. A 45-year-old male patient with a refractory FD presented with a crusting suppurative folliculitis and atrophic scarring patches on the scalp associated with pain and pruritus. We attempted relief of symptoms by reducing scalp inflammation and eliminating hair follicles through radiation. We delivered 11.0 Gy in two radiation series using tomotherapy, 5.0 Gy in 5 equivalent fractions as a first radiation course. The symptoms markedly decreased but did not totally disappear. Therefore, we delivered a second radiation series 4 months later with an additional 6 Gy. This led to almost complete epilation on the scalp and abolished pain and pruritus on the capillitium. The patient was regularly followed up until 26 months after radiotherapy. Draining lesions or exudation did not recur. He only experienced discrete hair regrowth in the occipital region with folliculitis 12 months after radiotherapy. These residual lesions are currently treated with laser epilation therapy. A radical approach to eliminating hair follicles by repeated radiation therapy may induce lasting relief of symptoms in chronic suppurative FD associated with persistent trichodynia. (orig.) [de

  2. Multibeam tomotherapy: A new treatment unit devised for multileaf collimation, intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Achterberg, Nils; Mueller, Reinhold G.

    2007-01-01

    A fully integrated system for treatment planning, application, and verification for automated multileaf collimator (MLC) based, intensity-modulated, image-guided, and adaptive radiation therapy (IMRT, IGRT and ART, respectively) is proposed. Patient comfort, which was the major development goal, will be achieved through a new unit design and short treatment times. Our device for photon beam therapy will consist of a new dual energy linac with five fixed treatment heads positioned evenly along one plane but one electron beam generator only. A minimum of moving parts increases technical reliability and reduces motion times to a minimum. Motion is allowed solely for the MLCs, the robotic patient table, and the small angle gantry rotation of ±36 deg. . Besides sophisticated electron beam guidance, this compact setup can be built using existing modules. The flattening-filter-free treatment heads are characterized by reduced beam-on time and contain apertures restricted in one dimension to the area of maximum primary fluence output. In the case of longer targets, this leads to a topographic intensity modulation, thanks to the combination of ''step and shoot'' MLC delivery and discrete patient couch motion. Owing to the limited number of beam directions, this multislice cone beam serial tomotherapy is referred to as ''multibeam tomotherapy.'' Every patient slice is irradiated by one treatment head at any given moment but for one subfield only. The electron beam is then guided to the next head ready for delivery, while the other heads are preparing their leaves for the next segment. The ''Multifocal MLC-positioning'' algorithm was programmed to enable treatment planning and optimize treatment time. We developed an overlap strategy for the longitudinally adjacent fields of every beam direction, in doing so minimizing the field match problem and the effects of possible table step errors. Clinical case studies show for the same or better planning target volume coverage

  3. Helical tomotherapy provides efficacy similar to that of intensity-modulated radiation therapy with dosimetric benefits for endometrial carcinoma

    Directory of Open Access Journals (Sweden)

    Hsieh CH

    2012-10-01

    Full Text Available Chen-Hsi Hsieh,1,4–6 Pei-Wei Shueng,1,3 Sheng-Mou Hsiao,2 Ming-Chow Wei,2 Wen-Yih Wu,2 Hsu-Dong Sun,2 Hui-Ju Tien,1 Li-Ying Wang,7 Yen-Ping Hsieh81Division of Radiation Oncology, Department of Radiology, 2Department of Obstetrics and Gynecology, Far Eastern Memorial Hospital, New Taipei City, 3Department of Radiation Oncology, National Defense Medical Center, 4Department of Medicine, 5Institute of Traditional Medicine, School of Medicine, National Yang-Ming University, 6Oriental Institute of Technology, New Taipei City, 7School and Graduate Institute of Physical Therapy, College of Medicine, National Taiwan University, Taipei, 8Department of Senior Citizen Service Management, National Taichung University of Science and Technology, Taichung, Taiwan, ChinaBackground: The purpose of this study was to compare the efficacy of intensity-modulated radiotherapy (IMRT and helical tomotherapy for endometrial cancer.Methods: Between November 1, 2006 and November 31, 2010, 31 patients with histologically confirmed endometrial cancer were enrolled. All enrolled patients received total abdominal hysterectomy and bilateral salpingo-oophorectomy with adjuvant whole pelvic IMRT or helical tomotherapy.Results: The actuarial 3-year overall survival, disease-free survival, locoregional control, and distant metastasis-free rates for the IMRT and helical tomotherapy groups were 87.5% versus 100%, 91.7% versus 51.7%, 91.7% versus 83.3%, and 91.7% versus 51.7%, respectively. The conformal index and uniformity index for IMRT versus helical tomotherapy was 1.25 versus 1.17 (P = 0.04 and 1.08 versus 1.05 (P < 0.01, respectively. Two of 31 patients with cervical stump failure were noted, one in the IMRT group and the other in the helical tomotherapy group. No acute or late grade 3 or 4 toxicities were noted, including proctitis, or genitourinary or gastrointestinal disturbances.Conclusion: Helical tomotherapy is as effective as IMRT and has better uniformity and

  4. Treatment of folliculitis decalvans using intensity-modulated radiation via tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Elsayad, Khaled; Kriz, Jan; Haverkamp, Uwe; Eich, Hans Theodor [University Hospital of Muenster, Department of Radiation Oncology, Muenster (Germany); Plachouri, Kerasia-Maria; Jeskowiak, Antonia [University Hospital of Muenster, Department of Dermatology, Muenster (Germany); Sunderkoetter, Cord [University Hospital of Muenster, Department of Dermatology, Muenster (Germany); University Hospital of Muenster, Department of Translational Dermatoninfectiology, Muenster (Germany)

    2015-11-15

    Folliculitis decalvans (FD) is a form of primary neutrophilic scarring alopecia that is characterized clinically by chronic suppurative folliculitis and often associated with pruritus or even pain. Treatment of FD is often difficult. Herein, we report a case of recalcitrant and painful folliculitis decalvans refractory to antibiotic and anti-inflammatory therapies, which was successfully treated by intensity-modulated radiotherapy (IMRT) in order to irreversibly eliminate hair follicles that prove to be one etiological trigger. A 45-year-old male patient with a refractory FD presented with a crusting suppurative folliculitis and atrophic scarring patches on the scalp associated with pain and pruritus. We attempted relief of symptoms by reducing scalp inflammation and eliminating hair follicles through radiation. We delivered 11.0 Gy in two radiation series using tomotherapy, 5.0 Gy in 5 equivalent fractions as a first radiation course. The symptoms markedly decreased but did not totally disappear. Therefore, we delivered a second radiation series 4 months later with an additional 6 Gy. This led to almost complete epilation on the scalp and abolished pain and pruritus on the capillitium. The patient was regularly followed up until 26 months after radiotherapy. Draining lesions or exudation did not recur. He only experienced discrete hair regrowth in the occipital region with folliculitis 12 months after radiotherapy. These residual lesions are currently treated with laser epilation therapy. A radical approach to eliminating hair follicles by repeated radiation therapy may induce lasting relief of symptoms in chronic suppurative FD associated with persistent trichodynia. (orig.) [German] Die Folliculitis decalvans (FD) ist eine Form der primaer neutrophilen Alopezie, welche klinisch durch Schmerzen und eitrige Follikel gekennzeichnet ist. Da es bisher kein einheitliches Behandlungskonzept gibt, wird hier ueber eine FD berichtet, welche trotz mehrfacher antibiotischer

  5. Intensity-modulated radiation therapy: dynamic MLC (DMLC) therapy, multisegment therapy and tomotherapy. An example of QA in DMLC therapy

    International Nuclear Information System (INIS)

    Webb, S.

    1998-01-01

    Intensity-modulated radiation therapy will make a quantum leap in tumor control. It is the new radiation therapy for the new millennium. The major methods to achieve IMRT are: 1. Dynamic multileaf collimator (DMLC) therapy, 2. multisegment therapy, and 3. tomotherapy. The principles of these 3 techniques are briefly reviewed. Each technique presents unique QA issues which are outlined. As an example this paper will present the results of a recent new study of an important QA concern in DMLC therapy. (orig.) [de

  6. Evaluation of two tomotherapy-based techniques for the delivery of whole-breast intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Gonzalez, Victor J.; Buchholz, Daniel J.; Langen, Katja M.; Olivera, Gustavo H.; Chauhan, Bhavin; Meeks, Sanford L.; Ruchala, Kenneth J.; Haimerl, Jason; Lu Weiguo; Kupelian, Patrick A.

    2006-01-01

    Purpose: To evaluate two different techniques for whole-breast treatments delivered using the Hi-ART II tomotherapy device. Methods and Materials: Tomotherapy uses the standard rotational helical delivery. Topotherapy uses a stationary gantry while delivering intensity-modulated treatments. CT scans from 5 breast cancer patients were used. The prescription dose was 50.4 Gy. Results: On average, 99% of the target volume received 95% of prescribed dose with either technique. If treatment times are restricted to less than 9 min, the average percentage ipsilateral lung receiving ≥20 Gy was 22% for tomotherapy vs. 10% for topotherapy. The ipsilateral lung receiving ≥50.4 Gy was 4 cc for tomotherapy vs. 27 cc for topotherapy. The percentage of left ventricle receiving ≥30 Gy was 14% with tomotherapy vs. 4% for topotherapy. The average doses to the contralateral breast and lung were 0.6 and 0.8 Gy, respectively, for tomotherapy vs. 0.4 and 0.3 Gy for topotherapy. Conclusions: Tomotherapy provides improved target dose homogeneity and conformality over topotherapy. If delivery times are restricted, topotherapy reduces the amount of heart and ipsilateral lung volumes receiving low doses. For whole-breast treatments, topotherapy is an efficient technique that achieves adequate target uniformity while maintaining low doses to sensitive structures

  7. Xerostomia in patients treated for oropharyngeal carcinoma: comparing linear accelerator-based intensity-modulated radiation therapy with helical tomotherapy.

    Science.gov (United States)

    Fortin, Israël; Fortin, Bernard; Lambert, Louise; Clavel, Sébastien; Alizadeh, Moein; Filion, Edith J; Soulières, Denis; Bélair, Manon; Guertin, Louis; Nguyen-Tan, Phuc Felix

    2014-09-01

    In comparison to sliding-window intensity-modulated radiation therapy (sw-IMRT), we hypothesized that helical tomotherapy (HT) would achieve similar locoregional control and, at the same time, decrease the parotid gland dose, thus leading to a xerostomia reduction. The association between radiation techniques, mean parotid dose, and xerostomia incidence, was reviewed in 119 patients with advanced oropharyngeal carcinoma treated with concurrent chemoradiation using sw-IMRT (n = 59) or HT (n = 60). Ipsilateral and contralateral parotid mean doses were significantly lower for patients treated with HT versus sw-IMRT: 24 Gy versus 32 Gy ipsilaterally and 20 Gy versus 25 Gy contralaterally. The incidence of grade ≥2 xerostomia was significantly lower in the HT group than in the sw-IMRT group: 12% versus 78% at 6 months, 3% versus 51% at 12 months, and 0% versus 25% at 24 months. Total parotid mean dose xerostomia at 6, 12, and 24 months. This retrospective series suggests that using HT can better spare the parotid glands while respecting quantitative analysis of normal tissue effects in the clinic (QUANTEC)'s criteria. Copyright © 2013 Wiley Periodicals, Inc.

  8. Preliminary comp arison of helical tomotherapy and mixed beams of unmodulated electrons and intensity modulated radiation therapy for treating superficial cancers of the parotid gland and nasal cavity

    Directory of Open Access Journals (Sweden)

    Blasi Olivier

    2011-12-01

    Full Text Available Abstract Background and Purpose To investigate combining unmodulated electron beams with intensity-modulated radiation therapy to improve dose distributions for superficial head and neck cancers, and to compare mixed beam plans with helical tomotherapy. Materials and methods Mixed beam and helical tomotherapy dose plans were developed for two patients with parotid gland tumors and two patients with nasal cavity tumors. Mixed beam plans consisted of various weightings of a enface electron beam and IMRT, which was optimized after calculation of the electron dose to compensate for heterogeneity in the electron dose distribution within the target volume. Results Helical tomotherapy plans showed dose conformity and homogeneity in the target volume that was equal to or better than the mixed beam plans. Electron-only plans tended to show the lowest doses to normal tissues, but with markedly worse dose conformity and homogeneity than in the other plans. However, adding a 20% IMRT dose fraction (i.e., IMRT:electron weighting = 1:4 to the electron plan restored target conformity and homogeneity to values comparable to helical tomotherapy plans, while maintaining lower normal tissue dose. Conclusions Mixed beam treatments offer some dosimetric advantages over IMRT or helical tomotherapy for target depths that do not exceed the useful range of the electron beam. Adding a small IMRT component (e.g., IMRT:electron weighting = 1:4 to electron beam plans markedly improved target dose homogeneity and conformity for the cases examined in this study.

  9. Preliminary comp arison of helical tomotherapy and mixed beams of unmodulated electrons and intensity modulated radiation therapy for treating superficial cancers of the parotid gland and nasal cavity

    International Nuclear Information System (INIS)

    Blasi, Olivier; Fontenot, Jonas D; Fields, Robert S; Gibbons, John P; Hogstrom, Kenneth R

    2011-01-01

    To investigate combining unmodulated electron beams with intensity-modulated radiation therapy to improve dose distributions for superficial head and neck cancers, and to compare mixed beam plans with helical tomotherapy. Mixed beam and helical tomotherapy dose plans were developed for two patients with parotid gland tumors and two patients with nasal cavity tumors. Mixed beam plans consisted of various weightings of a enface electron beam and IMRT, which was optimized after calculation of the electron dose to compensate for heterogeneity in the electron dose distribution within the target volume. Helical tomotherapy plans showed dose conformity and homogeneity in the target volume that was equal to or better than the mixed beam plans. Electron-only plans tended to show the lowest doses to normal tissues, but with markedly worse dose conformity and homogeneity than in the other plans. However, adding a 20% IMRT dose fraction (i.e., IMRT:electron weighting = 1:4) to the electron plan restored target conformity and homogeneity to values comparable to helical tomotherapy plans, while maintaining lower normal tissue dose. Mixed beam treatments offer some dosimetric advantages over IMRT or helical tomotherapy for target depths that do not exceed the useful range of the electron beam. Adding a small IMRT component (e.g., IMRT:electron weighting = 1:4) to electron beam plans markedly improved target dose homogeneity and conformity for the cases examined in this study

  10. Rapid Arc, helical tomotherapy, sliding window intensity modulated radiotherapy and three dimensional conformal radiation for localized prostate cancer: A dosimetric comparison

    Directory of Open Access Journals (Sweden)

    Rajesh A Kinhikar

    2014-01-01

    Full Text Available Objective: The objective of this study was to investigate the potential role of RapidArc (RA compared with helical tomotherapy (HT, sliding window intensity modulated radiotherapy (SW IMRT and three-dimensional conformal radiation therapy (3D CRT for localized prostate cancer. Materials and Methods: Prescription doses ranged from 60 Gy to planning target volume (PTV and 66.25 Gy for clinical target volume prostate (CTV-P over 25-30 fractions. PTV and CTV-P coverage were evaluated by conformity index (CI and homogeneity index (HI. Organ sparing comparison was done with mean doses to rectum and bladder. Results: CI 95 were 1.0 ± 0.01 (RA, 0.99 ± 0.01 (HT, 0.97 ± 0.02 (IMRT, 0.98 ± 0.02 (3D CRT for PTV and 1.0 ± 0.00 (RA, HT, SW IMRT and 3D CRT for CTV-P. HI was 0.11 ± 0.03 (RA, 0.16 ± 0.08 (HT, 0.12 ± 0.03 (IMRT, 0.06 ± 0.01 (3D CRT for PTV and 0.03 ± 0.00 (RA, 0.05 ± 0.01 (HT, 0.03 ± 0.01 (SW IMRT and 3D CRT for CTV-P. Mean dose to bladder were 23.68 ± 13.23 Gy (RA, 24.55 ± 12.51 Gy (HT, 19.82 ± 11.61 Gy (IMRT and 23.56 ± 12.81 Gy (3D CRT, whereas mean dose to rectum was 36.85 ± 12.92 Gy (RA, 33.18 ± 11.12 Gy (HT, IMRT and 38.67 ± 12.84 Gy (3D CRT. Conclusion: All studied intensity-modulated techniques yield treatment plans of significantly improved quality when compared with 3D CRT, with HT providing best organs at risk sparing and RA being the most efficient treatment option, reducing treatment time to 1.45-3.7 min and monitor unit to <400 for a 2 Gy fraction.

  11. Stereotactic Image-Guided Intensity Modulated Radiotherapy Using the HI-ART II Helical Tomotherapy System

    International Nuclear Information System (INIS)

    Holmes, Timothy W.; Hudes, Richard; Dziuba, Sylwester; Kazi, Abdul; Hall, Mark; Dawson, Dana

    2008-01-01

    The highly integrated adaptive radiation therapy (HI-ART II) helical tomotherapy unit is a new radiotherapy machine designed to achieve highly precise and accurate treatments at all body sites. The precision and accuracy of the HI-ART II is similar to that provided by stereotactic radiosurgery systems, hence the historical distinction between external beam radiotherapy and stereotactic procedures based on differing precision requirements is removed for this device. The objectives of this work are: (1) to describe stereotactic helical tomotherapy processes (SRS, SBRT); (2) to show that the precision and accuracy of the HI-ART meet the requirements defined for SRS and SBRT; and (3) to describe the clinical implementation of a stereotactic image-guided intensity modulated radiation therapy (IG-IMRT) system that incorporates optical motion management

  12. Hemithoracic intensity-modulated radiotherapy using helical tomotherapy for patients after extrapleural pneumonectomy for malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Ebara, Takeshi; Kawamura, Hidemasa; Kaminuma, Takuya

    2012-01-01

    Postoperative hemithoracic irradiation is regarded as an important part of the curative treatment for resectable malignant pleural mesothelioma (MPM). Because the clinical target volume in postoperative MPM is irregular and surrounded by dose-limiting critical structures, intensity-modulated radiation therapy (IMRT) is thought to be suitable. However, postoperative hemithoracic IMRT remains experimental due to a high incidence of fatal pneumonitis. Therefore, a Phase I dose escalation study for hemithoracic IMRT using helical tomotherapy was planned, and the results of the first three patients are herein reported because this technique may provide benefits to such patients. For 3 patients with postoperative MPM, who were treated by extrapleural pneumonectomy (EPP), a radiation dose of 45.0 Gy in 25 fractions was given to cover 95% of the PTV. The lung V5s of the three patients were 14.3%, 10.0%, and 31.3%, respectively. The V5s of the present plans was smaller than that of the recent IMRT planning studies. The lung V20s of these patients were 2.4%, 2.2%, and 4.3%, respectively. Their MLDs were 4.3 Gy, 3.4 Gy, and 5.8 Gy, respectively. The follow-up periods of the patients were 26, 14 and 9 months from initiation of IMRT, respectively. All patients were alive, although local and contralateral recurrences had developed in 1 patient. Only 1 patient had Grade 2 acute esophagitis and nausea. There was no treatment-related pneumonitis. Hemithoracic IMRT using helical tomotherapy may play a crucial role in adjuvant treatment for MPM after EPP. (author)

  13. Applicator-guided intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Low, Daniel A.; Grigsby, Perry W.; Dempsey, James F.; Mutic, Sasa; Williamson, Jeffrey F.; Markman, Jerry; Chao, K.S. Clifford; Klein, Eric E.; Purdy, James A.

    2002-01-01

    Purpose: We are introducing a novel method for delivering highly conformal dose distributions to cervical cancer tumors using external beam intensity-modulated radiation therapy. The method, termed applicator-guided intensity-modulated radiation therapy (AGIMRT), will use an applicator substitute placed in the vagina and uterus to provide spatial registration and immobilization of the gynecologic organs. The main reason for the applicator substitute will be to localize the fornices, cervix, and uterus with the expectation that the other nearby organs will also be reproducibly positioned with respect to the applicator substitute. Intensity-modulated radiation therapy (IMRT) dose distributions will be used as a substitute for high-dose-rate intracavitary brachytherapy procedures. The flexibility of IMRT will enable customized dose distributions that have the potential to reduce complications and improve local control, especially for locally advanced disease. Methods and Materials: To test the advantages of IMRT over intracavitary brachytherapy, volumetric scans of three cervical cancer patients were obtained with implanted CT-compatible applicators. IMRT dose distribution simulations using tomotherapy, were compared against intracavitary brachytherapy using cesium tubes to investigate the dosimetric differences of the two modalities. Because these tumor volumes do not image well on CT, the target volumes were defined as the isodose surface containing the traditional point A, defined as 2 cm superior to the vaginal fornices and 2 cm lateral to the intrauterine canal. One patient had a uterus that wrapped superior and anterior to the bladder. For this case, the cervix and uterus were selected as the target volume. To determine the potential for using an applicator substitute to localize internal organs, the posterior bladder and anterior rectal surfaces were localized relative to the colpostats. Comparisons of the colpostat-localized surfaces were conducted for two

  14. Film Dosimetry for Intensity Modulated Radiation Therapy

    International Nuclear Information System (INIS)

    Benites-Rengifo, J.; Martinez-Davalos, A.; Celis, M.; Larraga, J.

    2004-01-01

    Intensity Modulated Radiation Therapy (IMRT) is an oncology treatment technique that employs non-uniform beam intensities to deliver highly conformal radiation to the targets while minimizing doses to normal tissues and critical organs. A key element for a successful clinical implementation of IMRT is establishing a dosimetric verification process that can ensure that delivered doses are consistent with calculated ones for each patient. To this end we are developing a fast quality control procedure, based on film dosimetry techniques, to be applied to the 6 MV Novalis linear accelerator for IMRT of the Instituto Nacional de Neurologia y Neurocirugia (INNN) in Mexico City. The procedure includes measurements of individual fluence maps for a limited number of fields and dose distributions in 3D using extended dose-range radiographic film. However, the film response to radiation might depend on depth, energy and field size, and therefore compromise the accuracy of measurements. In this work we present a study of the dependence of Kodak EDR2 film's response on the depth, field size and energy, compared with those of Kodak XV2 film. The first aim is to devise a fast and accurate method to determine the calibration curve of film (optical density vs. doses) commonly called a sensitometric curve. This was accomplished by using three types of irradiation techniques: Step-and-shoot, dynamic and static fields

  15. Radiotherapy for Adult Medulloblastoma: Evaluation of Helical Tomotherapy, Volumetric Intensity Modulated Arc Therapy, and Three-Dimensional Conformal Radiotherapy and the Results of Helical Tomotherapy Therapy

    Directory of Open Access Journals (Sweden)

    Sun Zong-wen

    2018-01-01

    Full Text Available Introduction. All adult medulloblastoma (AMB patients should be treated with craniospinal irradiation (CSI postoperatively. Because of the long irradiation range, multiple radiation fields must be designed for conventional radiotherapy technology. CSI can be completed in only one session with helical tomotherapy (HT. We evaluated the dose of HT, volumetric intensity modulated arc therapy (VMAT, and three-dimensional conformal radiotherapy (3D-CRT of AMB and the results of 5 cases of AMB treated with HT. Methods. Complete craniospinal and posterior cranial fossa irradiation with HT, VMAT, and 3D-CRT and dose evaluation were performed. And results of 5 cases of AMB treated with HT were evaluated. Results. A large volume of tissue was exposed to low dose radiation in the organs at risk (OAR, while a small volume was exposed to high dose radiation with HT. The conformity and uniformity of the targets were good with HT and VMAT, and the volume of targets exposed to high dose with VMAT was larger than that of HT. The uniformity of 3D-CRT was also good, but the dose conformity was poor. The main toxicity was hematologic toxicity, without 4th-degree bone marrow suppression. There was 3rd-degree inhibition in the white blood cells, hemoglobin, and platelets. The three female patients suffered menstrual disorders during the course of radiation. Two female patients with heavy menstruation suffered 3rd-degree anemia inhibition, and 2 patients suffered amenorrhea after radiotherapy. Although menstrual cycle was normal, the third patient was not pregnant. Conclusion. CSI with HT is convenient for clinical practice, and the side effects are mild. With good conformity and uniformity, VMAT can also be used for selection in CSI. For poor conformity, 3D-CRT should not be the priority selection for CSI. In female patients, the ovaries should be protected.

  16. The pitfalls of dosimetric commissioning for intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Tohyama, Naoki; Kodama, Takashi; Hatano, K.

    2013-01-01

    Intensity modulated radiation therapy (IMRT) allows higher radiation dose to be focused to the target volumes while minimizing the dose to OAR. To start of clinical treatment in IMRTvwe must perform commissioning strictly than 3D-conformal radiotherapy (CRT). In this report, pitfalls of dosimetric commissioning for intensity modulated radiation therapy were reviewed. Multileaf collimator (MLC) offsets and MLC transmissions are important parameters in commissioning of RTPS for IMRT. Correction of depth scaling and fluence scaling is necessary for dose measurement using solid phantom. (author)

  17. Multi-centre experience of implementing image-guided intensity-modulated radiotherapy using the TomoTherapy platform

    International Nuclear Information System (INIS)

    Dean, J.C.; Tudor, G.S.J.; Mott, J.H.; Dunlop, P.R.; Morris, S.L.; Harron, E.C.; Christian, J.A.; Sanghera, P.; Elsworthy, M.; Burnet, N.G.

    2013-01-01

    Use of image guided (IG) intensity modulated radiotherapy (IMRT) is increasing, and helical tomotherapy provides an effective, integrated solution. Practical experience of implementation, shared at a recent UK TomoTherapy Users' meeting, may help centres introducing these techniques using TomoTherapy or other platforms. Seven centres participated, with data shared from 6, varying from 2500 - 4800 new patients per year. Case selection of patients “most likely” to benefit from IG-IMRT was managed in all centres by multi-professional groups comprising clinical oncologists, physicists, treatment planners and radiographers. Radical treatments ranged from 94% to 100%. The proportions of tumour types varied substantially: head and neck: range 0%–100% (mean of centres 50%), prostate: 3%–96% (mean of centres 28%). Head and neck cases were considered most likely to benefit from IMRT, prostate cases from IGRT, or IG-IMRT if pelvic nodes were being treated. IMRT was also selected for complex target volumes, to avoid field junctions, for technical treatment difficulties, and retreatments. Across the centres, every patient was imaged every day, with positional correction before treatment. In one centre, for prostate patients including pelvic treatment, the pelvis was also imaged weekly. All centres had designed a ‘ramp up’ of patient numbers, which was similar in 5. One centre, treating 96% prostate patients, started with 3 and increased to 36 patients per day within 3 months. The variation in case mix implies wide applicability of IG-IMRT. Daily on-line IGRT with IMRT can be routinely implemented into busy departments

  18. Intensity-Modulated Radiation Therapy (IMRT)

    Science.gov (United States)

    ... type your comment or suggestion into the following text box: Comment: E-mail: Area code: Phone no: Thank ... Cancer Treatment Head and Neck Cancer Treatment Introduction to Cancer Therapy (Radiation Oncology) ...

  19. Re-irradiation of unresectable recurrent head and neck cancer: using Helical Tomotherapy as image-guided intensity-modulated radiotherapy

    International Nuclear Information System (INIS)

    Jeong, Songmi; Yoo, Eun Jung; Kim, Ji Yoon; Han, Chi Wha; Kim, Ki Jun; Kay, Chul Seung

    2013-01-01

    Re-irradiation (re-RT) is considered a treatment option for inoperable locoregionally recurrent head and neck cancer (HNC) after prior radiotherapy. We evaluated the efficacy and safety of re-RT using Helical Tomotherapy as image-guided intensity-modulated radiotherapy in recurrent HNC. Patients diagnosed with recurrent HNC and received re-RT were retrospectively reviewed. Primary endpoint was overall survival (OS) and secondary endpoints were locoregional control and toxicities. The median follow-up period of total 9 patients was 18.7 months (range, 4.1 to 76 months) and that of 3 alive patients was 49 months (range, 47 to 76 months). Median dose of first radiotherapy and re-RT was 64.8 and 47.5 Gy10. Median cumulative dose of the two courses of radiotherapy was 116.3 Gy10 (range, 91.8 to 128.9 Gy10) while the median interval between the two courses of radiation was 25 months (range, 4 to 137 months). The response rate after re-RT of the evaluated 8 patients was 75% (complete response, 4; partial response, 2). Median locoregional relapse-free survival after re-RT was 11.9 months (range, 3.4 to 75.1 months) and 5 patients eventually presented with treatment failure (in-field failure, 2; in- and out-field failure, 2; out-field failure, 1). Median OS of the 8 patients was 20.3 months (range, 4.1 to 75.1 months). One- and two-year OS rates were 62.5% and 50%, respectively. Grade 3 leucopenia developed in one patient as acute toxicity, and grade 2 osteonecrosis and trismus as chronic toxicity in another patient. Re-RT using Helical Tomotherapy for previously irradiated patients with unresectable locoregionally recurrent HNC may be a feasible treatment option with long-term survival and acceptable toxicities.

  20. Re-irradiation of unresectable recurrent head and neck cancer: using Helical Tomotherapy as image-guided intensity-modulated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Songmi; Yoo, Eun Jung; Kim, Ji Yoon; Han, Chi Wha; Kim, Ki Jun; Kay, Chul Seung [The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2013-12-15

    Re-irradiation (re-RT) is considered a treatment option for inoperable locoregionally recurrent head and neck cancer (HNC) after prior radiotherapy. We evaluated the efficacy and safety of re-RT using Helical Tomotherapy as image-guided intensity-modulated radiotherapy in recurrent HNC. Patients diagnosed with recurrent HNC and received re-RT were retrospectively reviewed. Primary endpoint was overall survival (OS) and secondary endpoints were locoregional control and toxicities. The median follow-up period of total 9 patients was 18.7 months (range, 4.1 to 76 months) and that of 3 alive patients was 49 months (range, 47 to 76 months). Median dose of first radiotherapy and re-RT was 64.8 and 47.5 Gy10. Median cumulative dose of the two courses of radiotherapy was 116.3 Gy10 (range, 91.8 to 128.9 Gy10) while the median interval between the two courses of radiation was 25 months (range, 4 to 137 months). The response rate after re-RT of the evaluated 8 patients was 75% (complete response, 4; partial response, 2). Median locoregional relapse-free survival after re-RT was 11.9 months (range, 3.4 to 75.1 months) and 5 patients eventually presented with treatment failure (in-field failure, 2; in- and out-field failure, 2; out-field failure, 1). Median OS of the 8 patients was 20.3 months (range, 4.1 to 75.1 months). One- and two-year OS rates were 62.5% and 50%, respectively. Grade 3 leucopenia developed in one patient as acute toxicity, and grade 2 osteonecrosis and trismus as chronic toxicity in another patient. Re-RT using Helical Tomotherapy for previously irradiated patients with unresectable locoregionally recurrent HNC may be a feasible treatment option with long-term survival and acceptable toxicities.

  1. Risk of radiation-induced pneumonitis after helical and static-port tomotherapy in lung cancer patients and experimental rats

    International Nuclear Information System (INIS)

    Zhang, Xianglan; Shin, You Keun; Zheng, Zhenlong; Zhu, Lianhua; Lee, Ik Jae

    2015-01-01

    Radiotherapy (RT) is one of the major non-operative treatment modalities for treating lung cancer. Tomotherapy is an advanced type of intensity-modulated radiotherapy (IMRT) in which radiation may be delivered in a helical fashion. However, unexpected pneumonitis may occur in patients treated with tomotherapy, especially in combination with chemotherapy, as a result of extensive low-dose radiation of large lung volumes. The aim of our study was to investigate the risk of radiation-induced pneumonitis after helical-mode and static-mode tomotherapy in patients with lung cancer and in an animal model. A total of 63 patients with primary lung cancer who were treated with static or helical tomotherapy with or without concurrent chemoradiotherapy (CCRT) were analyzed. Additionally, rats with radiation-induced pulmonary toxicity, which was induced by the application of helical or static tomography with or without CCRT, were evaluated. Helical-mode tomotherapy resulted in a significantly higher rate of late radiation pneumonitis in lung cancer patients than static-mode tomotherapy when evaluated by the Radiation Therapy Oncology Group (RTOG) and National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE) scoring system. In the animal model, helical tomotherapy alone induced significantly higher expression of interleukin (IL)-1α, IL-1β, IL-6, and transforming growth factor (TGF)-β in lung specimens, especially on the untreated side, compared to static tomotherapy alone. Additionally, rats treated with helical tomotherapy and CCRT demonstrated significantly higher expression of inflammatory cytokines compared to those treated with static tomotherapy and CCRT. Rat models treated with tomotherapy with or without CCRT could present similar patterns of pulmonary toxicity to those shown in lung cancer patients. The models can be used in further investigations of radiation induced pulmonary toxicity

  2. Intensity-modulated radiation therapy clinical evidence and techniques

    CERN Document Server

    Nishimura, Yasumasa

    2015-01-01

    Successful clinical use of intensity-modulated radiation therapy (IMRT) represents a significant advance in radiation oncology. Because IMRT can deliver high-dose radiation to a target with a reduced dose to the surrounding organs, it can improve the local control rate and reduce toxicities associated with radiation therapy. Since IMRT began being used in the mid-1990s, a large volume of clinical evidence of the advantages of IMRT has been collected. However, treatment planning and quality assurance (QA) of IMRT are complicated and difficult for the clinician and the medical physicist. This book, by authors renowned for their expertise in their fields, provides cumulative clinical evidence and appropriate techniques for IMRT for the clinician and the physicist. Part I deals with the foundations and techniques, history, principles, QA, treatment planning, radiobiology and related aspects of IMRT. Part II covers clinical applications with several case studies, describing contouring and dose distribution with cl...

  3. Linear algebraic methods applied to intensity modulated radiation therapy.

    Science.gov (United States)

    Crooks, S M; Xing, L

    2001-10-01

    Methods of linear algebra are applied to the choice of beam weights for intensity modulated radiation therapy (IMRT). It is shown that the physical interpretation of the beam weights, target homogeneity and ratios of deposited energy can be given in terms of matrix equations and quadratic forms. The methodology of fitting using linear algebra as applied to IMRT is examined. Results are compared with IMRT plans that had been prepared using a commercially available IMRT treatment planning system and previously delivered to cancer patients.

  4. Energy and intensity modulated radiation therapy with electrons

    OpenAIRE

    Olofsson, Lennart

    2005-01-01

    In recent years intensity modulated radiation therapy with photons (xIMRT) has gained attention due to its ability to reduce the dose in the tissues close to the tumour volume. However, this technique also results in a large low dose volume. Electron IMRT (eIMRT) has the potential to reduce the integral dose to the patient due to the dose fall off in the electron depth dose curves. This dose fall off makes it possible to modulate the dose distribution in the direction of the beam by selecting...

  5. Optimization of brain tumor dose using intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Elbakery, Andaria Elhanfi Elmaki

    2016-04-01

    Intensity Modulated Radiation Therapy (IMRT) become an essential technique that achieves the goal of radiation therapy, maximum target dose and minimum dose for healthy tissues. Dose optimization was applied for brain tumor through as set of constrains given to the software. Fifteen patients were selected for IMRT planning and delineation was done using special software (fical). All data was tranferred to the treatment planning system. Kon Rad planning system was used in this work. The planning was evaluated with homogeneity index and dose volume histogram ( DVH). The 0ptimization was achieved from converge of target volume with 5% as maxim dose and 95% as the minimum dose. The homogeneity index that calculated for most of patients was approcimately equal to 1. It means that converge was good and the optimization fulfilled. For organs at risk (OAR) the dose was below the tolerances and the mean dose and maxim dose were calculated. (Author)

  6. Clinical implementation and quality assurance for intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Ma, C.-M.; Price, R.; McNeeley, S.; Chen, L.; Li, J.S.; Wang, L.; Ding, M.; Fourkal, E.; Qin, L.

    2002-01-01

    This paper describes the clinical implementation and quality assurance (QA) for intensity-modulated radiation therapy (IMRT) based on the experience at Fox Chase Cancer Center, Philadelphia, USA. We will review our procedures for the clinical implementation of the IMRT technique and the requirements for patient immobilization, target delineation, treatment optimization, beam delivery and system administration. We will discuss the dosimetric requirements and measurement procedures for beam commissioning and dosimetry verification for IMRT. We will examine the details of model-based dose calculation for IMRT treatment planning and the potential problems with such dose calculation algorithms. We will discuss the effect of beam delivery systems on the actual dose distributions received by the patients and the methods to incorporate such effects in the treatment optimization process. We will investigate the use of the Monte Carlo method for dose calculation and treatment verification for IMRT

  7. Image-guided intensity modulated radiotherapy with helical tomotherapy for postoperative treatment of high-risk oral cavity cancer

    International Nuclear Information System (INIS)

    Hsieh, Chen-Hsi; Hsieh, Yen-Ping; Lin, Shoei Long; Chen, Chun-Yi; Chen, Chien-An; Shueng, Pei-Wei; Kuo, Ying-Shiung; Liao, Li-Jen; Hu, Kawang-Yu; Lin, Shih-Chiang; Wu, Le-Jung; Lin, Yu-Chin; Chen, Yu-Jen; Wang, Li-Ying

    2011-01-01

    The aim of this study was to assess the treatment results and toxicity profiles of helical tomotherapy (HT) for postoperative high-risk oral cavity cancer. From December 6, 2006 through October 9, 2009, 19 postoperative high-risk oral cavity cancer patients were enrolled. All of the patients received HT with (84%) or without (16%) chemotherapy. The median follow-up time was 17 months. The 2-year overall survival, disease-free survival, locoregional control, and distant metastasis-free rates were 94%, 84%, 92%, and 94%, respectively. The package of overall treatment time > 13 wk, the interval between surgery and radiation ≤ 6 wk, and the overall treatment time of radiation ≤ 7 wk was 21%, 84%, and 79%, respectively. The percentage of grade 3 mucositis, dermatitis, and leucopenia was 42%, 5% and 5%, respectively. HT achieved encouraging clinical outcomes for postoperative high-risk oral cavity cancer patients with high compliance. A long-term follow-up study is needed to confirm these preliminary findings

  8. Prone Breast Intensity Modulated Radiation Therapy: 5-Year Results

    Energy Technology Data Exchange (ETDEWEB)

    Osa, Etin-Osa O.; DeWyngaert, Keith [Department of Radiation Oncology, New York University School of Medicine, New York, New York (United States); Roses, Daniel [Department of Surgery, New York University School of Medicine, New York, New York (United States); Speyer, James [Department of Medical Oncology, New York University School of Medicine, New York, New York (United States); Guth, Amber; Axelrod, Deborah [Department of Surgery, New York University School of Medicine, New York, New York (United States); Fenton Kerimian, Maria [Department of Radiation Oncology, New York University School of Medicine, New York, New York (United States); Goldberg, Judith D. [Department of Population Health, New York University School of Medicine, New York, New York (United States); Formenti, Silvia C., E-mail: Silvia.formenti@nyumc.org [Department of Radiation Oncology, New York University School of Medicine, New York, New York (United States)

    2014-07-15

    Purpose: To report the 5-year results of a technique of prone breast radiation therapy delivered by a regimen of accelerated intensity modulated radiation therapy with a concurrent boost to the tumor bed. Methods and Materials: Between 2003 and 2006, 404 patients with stage I-II breast cancer were prospectively enrolled into 2 consecutive protocols, institutional trials 03-30 and 05-181, that used the same regimen of 40.5 Gy/15 fractions delivered to the index breast over 3 weeks, with a concomitant daily boost to the tumor bed of 0.5 Gy (total dose 48 Gy). All patients were treated after segmental mastectomy and had negative margins and nodal assessment. Patients were set up prone: only if lung or heart volumes were in the field was a supine setup attempted and chosen if found to better spare these organs. Results: Ninety-two percent of patients were treated prone, 8% supine. Seventy-two percent had stage I, 28% stage II invasive breast cancer. In-field lung volume ranged from 0 to 228.27 cm{sup 3}, mean 19.65 cm{sup 3}. In-field heart volume for left breast cancer patients ranged from 0 to 21.24 cm{sup 3}, mean 1.59 cm{sup 3}. There was no heart in the field for right breast cancer patients. At a median follow-up of 5 years, the 5-year cumulative incidence of isolated ipsilateral breast tumor recurrence was 0.82% (95% confidence interval [CI] 0.65%-1.04%). The 5-year cumulative incidence of regional recurrence was 0.53% (95% CI 0.41%-0.69%), and the 5-year overall cumulative death rate was 1.28% (95% CI 0.48%-3.38%). Eighty-two percent (95% CI 77%-85%) of patients judged their final cosmetic result as excellent/good. Conclusions: Prone accelerated intensity modulated radiation therapy with a concomitant boost results in excellent local control and optimal sparing of heart and lung, with good cosmesis. Radiation Therapy Oncology Group protocol 1005, a phase 3, multi-institutional, randomized trial is ongoing and is evaluating the equivalence of a similar dose and

  9. Current status of intensity-modulated radiation therapy (IMRT)

    International Nuclear Information System (INIS)

    Hatano, Kazuo; Araki, Hitoshi; Sakai, Mitsuhiro

    2007-01-01

    External-beam radiation therapy has been one of the treatment options for prostate cancer. The dose response has been observed for a dose range of 64.8-81 Gy. The problem of external-beam radiotherapy (RT) for prostate cancer is that as the dose increases, adverse effects also increase. Three-dimensional conformal radiation therapy (3D-CRT) has enabled us to treat patients with up to 72-76 Gy to the prostate, with a relatively acceptable risk of late rectal bleeding. Recently, intensity-modulated radiation therapy (IMRT) has been shown to deliver a higher dose to the target with acceptable low rates of rectal and bladder complications. The most important things to keep in mind when using an IMRT technique are that there is a significant trade-off between coverage of the target, avoidance of adjacent critical structures, and the inhomogeneity of the dose within the target. Lastly, even with IMRT, it should be kept in mind that a ''perfect'' plan that creates completely homogeneous coverage of the target volume and zero or small dose to the adjacent organs at risk is not always obtained. Participating in many treatment planning sessions and arranging the beams and beam weights create the best approach to the best IMRT plan. (author)

  10. Preoperative intensity modulated radiation therapy for retroperitoneal sarcoma.

    Science.gov (United States)

    El-Bared, Nancy; Taussky, Daniel; Mehiri, Selma; Patocskai, Erika; Roberge, David; Donath, David

    2014-06-01

    The use of intensity modulated radiation therapy (IMRT) has allowed for the administration of high doses to retroperitoneal sarcomas (RSTS) while limiting toxicity to adjacent organs. The purpose of our study is to assess the outcome and toxicities of patients with RSTS treated with neo-adjuvant external beam radiation (EBRT) therapy using IMRT. This is a retrospective study of 21 patients treated with preoperative IMRT for primary or recurrent RSTS between 2005 and 2011. Overall survival (OS) and local recurrence free survival (LRFS) were computed using the Kaplan-Meier method (log-rank test). Acute and chronic toxicities were assessed using the CTCAE v. 3 criteria. The actuarial 2 and 3-year OS was 66% for both and the 5-year OS was 51%. As for LRFS it was 57% at 2 and 3-year and 51% for the 5-year LRFS. Factors predictive for local control were microscopically negative margins (p = 0.022), a median tumor diameter <15 cm (p = 0.007) and pathology of liposarcoma (p = 0.021). Furthermore, patients treated for recurrent disease fared worse (p = 0.04) in local control than patients treated for primary disease. As for OS, patients treated for Grade 1 histology had a better outcome (p 5 0.05). EBRT was generally well tolerated. Acute gastrointestinal (GI) Grade 1 or 2 toxicities occurred in 33% of patients and one patient had unexplained post-radiation Grade 2 fever that resolved after tumor resection. As for chronic toxicities 24% of our patients presented Grade 1 GI toxicity and one patient presented Grade 3 small bowel stenosis not clearly due to radiation toxicity. Despite the location and volume of the tumors treated, preoperative IMRT was very well tolerated in our patients with retroperitoneal sarcoma. Unfortunately local recurrences remain common and dose escalation is to be considered.

  11. Intensity-modulated radiation therapy for anal carcinoma

    International Nuclear Information System (INIS)

    Peiffert, D.; Moreau-Claeys, M.V.; Tournier-Rangeard, L.; Huger, S.; Marchesi, V.

    2011-01-01

    Anal canal carcinoma are highly curable by irradiation, combined with chemotherapy in locally advanced disease, with preservation of sphincter function. The clinical target volume for the nodes is extended, often including the inguinal nodes, which is not usual for other pelvic tumours. Acute and late effects are correlated with the volume and dose delivered to organs at risk, i. e. small bowel, bladder and increased by concomitant chemotherapy. Intensity modulated irradiation (IMRT) makes it possible to optimize the dose distribution in this 'complex U shaped' volume, while maintaining the dose distribution for the target volumes. The conversion from conformal irradiation to IMRT necessitates good knowledge of the definition and skills to delineate target volumes and organs at risk, including new volumes needed to optimize the dose distribution. Dosimetric and clinical benefits of IMRT are described, based on early descriptions and evidence-based publication. The growing development of IMRT in anal canal radiotherapy must be encouraged, and long-term benefits should be soon published. Radiation oncologists should precisely learn IMRT recommendations before starting the technique, and evaluate its early and late results for adverse effects, but also for long-term tumour control. (authors)

  12. Ultrasound-based guidance of intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Fung, Albert Y.C.; Ayyangar, Komanduri M.; Djajaputra, David; Nehru, Ramasamy M.; Enke, Charles A.

    2006-01-01

    In ultrasound-guided intensity-modulated radiation therapy (IMRT) of prostate cancer, ultrasound imaging ascertains the anatomical position of patients during x-ray therapy delivery. The ultrasound transducers are made of piezoelectric ceramics. The same crystal is used for both ultrasound production and reception. Three-dimensional (3D) ultrasound devices capture and correlate series of 2-dimensional (2D) B-mode images. The transducers are often arranged in a convex array for focusing. Lower frequency reaches greater depth, but results in low resolution. For clear image, some gel is usually applied between the probe and the skin contact surface. For prostate positioning, axial and sagittal scans are performed, and the volume contours from computed tomography (CT) planning are superimposed on the ultrasound images obtained before radiation delivery at the linear accelerator. The planning volumes are then overlaid on the ultrasound images and adjusted until they match. The computer automatically deduces the offset necessary to move the patient so that the treatment area is in the correct location. The couch is translated as needed. The currently available commercial equipment can attain a positional accuracy of 1-2 mm. Commercial manufacturer designs differ in the detection of probe coordinates relative to the isocenter. Some use a position-sensing robotic arm, while others have infrared light-emitting diodes or pattern-recognition software with charge-couple-device cameras. Commissioning includes testing of image quality and positional accuracy. Ultrasound is mainly used in prostate positioning. Data for 7825 daily fractions of 234 prostate patients indicated average 3D inter-fractional displacement of about 7.8 mm. There was no perceivable trend of shift over time. Scatter plots showed slight prevalence toward superior-posterior directions. Uncertainties of ultrasound guidance included tissue inhomogeneities, speckle noise, probe pressure, and inter

  13. Intensity Modulated Radiation Therapy. Development of the technique

    International Nuclear Information System (INIS)

    Rafailovici, L.; Alva, R.; Chiozza, J.; Donato, H.; Falomo, S.; Cardiello, C.; Furia, O.; Martinez, A.; Filomia, M.L.; Sansogne, R.; Arbiser, S.; Dosoretz, B.

    2008-01-01

    Full text: Introduction: Intensity Modulated Radiation Therapy (IMRT) is a result of advances in computer sciences that allowed the development of new technology related to planning and radiation therapy. IMRT was developed to homogenize the dose in the target volumes and decrease the dose in the surrounding healthy tissue. Using a software with high calculation capacity a simultaneous irradiation with different doses in a given volume is achieved. IMRT is based on internal planning. Material and methods: 628 patients were treated with IMRT in prostate lesions, head and neck, breast, thorax, abdomen and brain since August 2008. The software for IMRT is the XIO CMS and the accelerator used is a Varian Clinac 6 / 100. IMRT requires a first simulation, where immobilization systems are selected (mats, thermoplastic masks, among others) and the demarcation of the target structures, healthy tissue and dose prescription by a tattoo. Images of CT / MRI are merged when necessary. Once the system made the treatment optimization, this one is regulated by modulators. These are produced by numerical control machines from digital files produced by software. In a second modulation the planned irradiation is checked and tattoo is carried out according with this. We have a strict process of quality assurance to assess the viability of the plan before its implementation. We use the Map Check it possible to compare the dose on the central axis and the distribution in the whole plane regarding to that generated by the planning system. From 03/2008 the virtual simulation process was implemented integrating the described stages. Results and Conclusions: IMRT is a complex technique. The meticulous planning, implementation of process and quality control allows the use of this technique in a reliable and secure way. With IMRT we achieved a high level of dose conformation, less irradiation of healthy tissue, lower rates of complications and the dose escalation for some tumors. (authors) [es

  14. Intensity Modulated Radiation Therapy With Dose Painting to Treat Rhabdomyosarcoma

    International Nuclear Information System (INIS)

    Yang, Joanna C.; Dharmarajan, Kavita V.; Wexler, Leonard H.; La Quaglia, Michael P.; Happersett, Laura; Wolden, Suzanne L.

    2012-01-01

    Purpose: To examine local control and patterns of failure in rhabdomyosarcoma patients treated with intensity modulated radiation therapy (RT) with dose painting (DP-IMRT). Patients and Methods: A total of 41 patients underwent DP-IMRT with chemotherapy for definitive treatment. Nineteen also underwent surgery with or without intraoperative RT. Fifty-six percent had alveolar histologic features. The median interval from beginning chemotherapy to RT was 17 weeks (range, 4-25). Very young children who underwent second-look procedures with or without intraoperative RT received reduced doses of 24-36 Gy in 1.4-1.8-Gy fractions. Young adults received 50.4 Gy to the primary tumor and lower doses of 36 Gy in 1.8-Gy fractions to at-risk lymph node chains. Results: With 22 months of median follow-up, the actuarial local control rate was 90%. Patients aged ≤7 years who received reduced overall and fractional doses had 100% local control, and young adults had 79% (P=.07) local control. Three local failures were identified in young adults whose primary target volumes had received 50.4 Gy in 1.8-Gy fractions. Conclusions: DP-IMRT with lower fractional and cumulative doses is feasible for very young children after second-look procedures with or without intraoperative RT. DP-IMRT is also feasible in adolescents and young adults with aggressive disease who would benefit from prophylactic RT to high-risk lymph node chains, although dose escalation might be warranted for improved local control. With limited follow-up, it appears that DP-IMRT produces local control rates comparable to those of sequential IMRT in patients with rhabdomyosarcoma.

  15. Head and neck intensity modulated radiation therapy leads to an increase of opportunistic oral pathogens

    NARCIS (Netherlands)

    Schuurhuis, Jennifer M.; Stokman, Monique A.; Witjes, Max J. H.; Langendijk, Johannes A.; van Winkelhoff, Arie J.; Vissink, Arjan; Spijkervet, Frederik K. L.

    Objectives: The introduction of intensity modulated radiation therapy (IMRT) has led to new possibilities in the treatment of head and neck cancer (HNC). Limited information is available on how this more advanced radiation technique affects the oral microflora. In a prospective study we assessed the

  16. Acute esophagus toxicity in lung cancer patients after intensity modulated radiation therapy and concurrent chemotherapy

    NARCIS (Netherlands)

    Kwint, Margriet; Uyterlinde, Wilma; Nijkamp, Jasper; Chen, Chun; de Bois, Josien; Sonke, Jan-Jakob; van den Heuvel, Michel; Knegjens, Joost; van Herk, Marcel; Belderbos, José

    2012-01-01

    The purpose of this study was to investigate the dose-effect relation between acute esophageal toxicity (AET) and the dose-volume parameters of the esophagus after intensity modulated radiation therapy (IMRT) and concurrent chemotherapy for patients with non-small cell lung cancer (NSCLC). One

  17. Unilateral and bilateral neck SIB for head and neck cancer patients. Intensity-modulated proton therapy, tomotherapy, and RapidArc

    Energy Technology Data Exchange (ETDEWEB)

    Stromberger, Carmen; Budach, Volker; Ghadjar, Pirus; Wlodarczyk, Waldemar; Marnitz, Simone [Charite - Universitaetsmedizin Berlin, Department of Radiation Oncology and Radiotherapy, Berlin (Germany); Cozzi, Luca; Fogliata, Antonella [Humanitas Cancer Center Milan, Radiotherapy and Radiosurgery Department, Milan (Italy); Jamil, Basil [Klinikum Frankfurt Oder, Praxis fuer Strahlentherapie, Frankfurt Oder (Germany); Raguse, Jan D. [Clinic for Oral and Maxillofacial Surgery, Berlin (Germany); Boettcher, Arne [Charite - Universitaetsmedizin Berlin, Department of Otorhinolaryngology, Berlin (Germany)

    2016-04-15

    To compare simultaneous integrated boost plans for intensity-modulated proton therapy (IMPT), helical tomotherapy (HT), and RapidArc therapy (RA) for patients with head and neck cancer. A total of 20 patients with squamous cell carcinoma of the head and neck received definitive chemoradiation with bilateral (n = 14) or unilateral (n = 6) neck irradiation and were planned using IMPT, HT, and RA with 54.4, 60.8, and 70.4 GyE/Gy in 32 fractions. Dose distributions, coverage, conformity, homogeneity to planning target volumes (PTV)s and sparing of organs at risk and normal tissue were compared. All unilateral and bilateral plans showed excellent PTV coverage and acceptable dose conformity. For unilateral treatment, IMPT delivered substantially lower mean doses to contralateral salivary glands (< 0.001-1.1 Gy) than both rotational techniques did (parotid gland: 6-10 Gy; submandibular gland: 15-20 Gy). Regarding the sparing of classical organs at risk for bilateral treatment, IMPT and HT were similarly excellent and RA was satisfactory. For unilateral neck irradiation, IMPT may minimize the dry mouth risk in this subgroup but showed no advantage over HT for bilateral neck treatment regarding classical organ-at-risk sparing. All methods satisfied modern standards regarding toxicity and excellent target coverage for unilateral and bilateral treatment of head and neck cancer at the planning level. (orig.) [German] Planvergleich von intensitaetsmodulierter Protonentherapie (IMPT), Tomotherapie (HT) und RapidArc-Therapie (RA) fuer Patienten mit Plattenepithelkarzinomen der Kopf-Hals-Region unter Anwendung des simultan integrierten Boost-Konzepts (SIB). Fuer 20 Patienten mit Plattenepithelkarzinomen der Kopf-Hals-Region und bilateraler (n = 14) oder unilateraler (n = 6) zervikaler primaerer Radiochemotherapie erfolgte eine IMPT-, HT- und RA-Planung mit 54,4, 60,8 und 70,4 GyE/Gy in 32 Fraktionen. Die Dosisverteilung, Abdeckung, Konformitaet und Homogenitaet der PTVs sowie die

  18. Intensity-Modulated Radiotherapy (IMRT) vs Helical Tomotherapy (HT) in Concurrent Chemoradiotherapy (CRT) for Patients with Anal Canal Carcinoma (ACC): an analysis of dose distribution and toxicities

    International Nuclear Information System (INIS)

    Yeung, Rosanna; McConnell, Yarrow; Warkentin, Heather; Graham, Darren; Warkentin, Brad; Joseph, Kurian; Doll, Corinne M

    2015-01-01

    Intensity-modulated radiotherapy (IMRT) and helical tomotherapy (HT) have been adopted for radiotherapy treatment of anal canal carcinoma (ACC) due to better conformality, dose homogeneity and normal-tissue sparing compared to 3D-CRT. To date, only one published study compares dosimetric parameters of IMRT vs HT in ACC, but there are no published data comparing toxicities. Our objectives were to compare dosimetry and toxicities between these modalities. This is a retrospective study of 35 ACC patients treated with radical chemoradiotherapy at two tertiary cancer institutions from 2008–2010. The use of IMRT vs HT was primarily based on center availability. The majority of patients received fluorouracil (5-FU) and 1–2 cycles of mitomycin C (MMC); 2 received 5-FU and cisplatin. Primary tumor and elective nodes were prescribed to ≥54Gy and ≥45Gy, respectively. Patients were grouped into two cohorts: IMRT vs HT. The primary endpoint was a dosimetric comparison between the cohorts; the secondary endpoint was comparison of toxicities. 18 patients were treated with IMRT and 17 with HT. Most IMRT patients received 5-FU and 1 MMC cycle, while most HT patients received 2 MMC cycles (p < 0.01), based on center policy. HT achieved more homogenous coverage of the primary tumor (HT homogeneity and uniformity index 0.14 and 1.02 vs 0.29 and 1.06 for IMRT, p = 0.01 and p < 0.01). Elective nodal coverage did not differ. IMRT achieved better bladder, femoral head and peritoneal space sparing (V30 and V40, p ≤ 0.01), and lower mean skin dose (p < 0.01). HT delivered lower bone marrow (V10, p < 0.01) and external genitalia dose (V20 and V30, p < 0.01). Grade 2+ hematological and non-hematological toxicities were similar. Febrile neutropenia and unscheduled treatment breaks did not differ (both p = 0.13), nor did 3-year overall and disease-free survival (p = 0.13, p = 0.68). Chemoradiotherapy treatment of ACC using IMRT vs HT results in differences in dose homogenity and

  19. The role of Cobalt-60 source in Intensity Modulated Radiation Therapy: From modeling finite sources to treatment planning and conformal dose delivery

    Science.gov (United States)

    Dhanesar, Sandeep Kaur

    Cobalt-60 (Co-60) units played an integral role in radiation therapy from the mid-1950s to the 1970s. Although they continue to be used to treat cancer in some parts of the world, their role has been significantly reduced due to the invention of medical linear accelerators. A number of groups have indicated a strong potential for Co-60 units in modern radiation therapy. The Medical Physics group at the Cancer Center of the Southeastern Ontario and Queen's University has shown the feasibility of Intensity Modulated Radiation Therapy (IMRT) via simple conformal treatment planning and dose delivery using a Co-60 unit. In this thesis, initial Co-60 tomotherapy planning investigations on simple uniform phantoms are extended to actual clinical cases based on patient CT data. The planning is based on radiation dose data from a clinical Co-60 unit fitted with a multileaf collimator (MLC) and modeled in the EGSnrc Monte Carlo system. An in house treatment planning program is used to calculate IMRT dose distributions. Conformal delivery in a single slice on a uniform phantom based on sequentially delivered pencil beams is verified by Gafchromic film. Volumetric dose distributions for Co-60 serial tomotherapy are then generated for typical clinical sites that had been treated at our clinic by conventional 6MV IMRT using Varian Eclipse treatment plans. The Co-60 treatment plans are compared with the clinical IMRT plans using conventional matrices such as dose volume histograms (DVH). Dose delivery based on simultaneously opened MLC leaves is also explored and a novel MLC segmentation method is proposed. In order to increase efficiency of dose calculations, a novel convolution based fluence model for treatment planning is also proposed. The ion chamber measurements showed that the Monte Carlo modeling of the beam data under the MIMiC MLC is accurate. The film measurements from the uniform phantom irradiations confirm that IMRT plans from our in-house treatment planning system

  20. Intensity-modulated radiation therapy: a review with a physics perspective.

    Science.gov (United States)

    Cho, Byungchul

    2018-03-01

    Intensity-modulated radiation therapy (IMRT) has been considered the most successful development in radiation oncology since the introduction of computed tomography into treatment planning that enabled three-dimensional conformal radiotherapy in 1980s. More than three decades have passed since the concept of inverse planning was first introduced in 1982, and IMRT has become the most important and common modality in radiation therapy. This review will present developments in inverse IMRT treatment planning and IMRT delivery using multileaf collimators, along with the associated key concepts. Other relevant issues and future perspectives are also presented.

  1. Assessment of Organ Motion in Postoperative Endometrial and Cervical Cancer Patients Treated With Intensity-Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Eleanor E.R., E-mail: Eleanor.harris@moffitt.org [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Latifi, Kujtim; Rusthoven, Chad; Javedan, Ken; Forster, Kenneth [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States)

    2011-11-15

    Purpose: Intensity-modulated radiation therapy (IMRT) may be useful to reduce toxicity in gynecologic cancer patients requiring postoperative pelvic irradiation. This study was undertaken to quantify vaginal wall organ motion during the course of postoperative pelvic irradiation using pelvic IMRT. Methods and Materials: Twenty-two consecutive patients treated with postoperative pelvic IMRT on helical tomotherapy had fiducial markers placed at the vaginal apex prior to simulation then daily megavoltage computed tomography (CT) scans for positioning. The daily positions of the fiducials were registered and measured in reference to the initial CT scan to quantify the degree of vaginal wall organ motion during the entire course of therapy. Results: The total motion of the fiducials center of mass (COM) was a median of 5.8 mm (range, 0.6-20.2 mm), and 95% of all COM positions fell within 15.7 mm of their original position. Directional margins of 3.1 mm along the right-left axis, 9.5 mm along the superoinferior axis, and of 12.1 mm along the anteroposterior axis encompassed the vaginal fiducials in 95% of treatments. Mean organ deformation for all patients was 3.9 mm, (range, 0-27.5 mm; standard deviation, 3.1 mm), with significant distortions of greater than 10 mm in 17% of secondary image sets. Conclusions: These data suggest a planning target volume margin of 16 mm will account for maximal organ motion in the majority of gynecologic patients undergoing postoperative pelvic IMRT, and it may be possible to incorporate directional motion into the planning target volume margin.

  2. Quality of Intensity Modulated Radiation Therapy Treatment Plans Using a (60)Co Magnetic Resonance Image Guidance Radiation Therapy System

    DEFF Research Database (Denmark)

    Wooten, H Omar; Green, Olga; Yang, Min

    2015-01-01

    PURPOSE: This work describes a commercial treatment planning system, its technical features, and its capabilities for creating (60)Co intensity modulated radiation therapy (IMRT) treatment plans for a magnetic resonance image guidance radiation therapy (MR-IGRT) system. METHODS AND MATERIALS...

  3. Radiation efficacy and biological risk from whole-breast irradiation via intensity modulated radiation therapy (IMRT)

    Science.gov (United States)

    Desantis, David M.

    Radiotherapy is an established modality for women with breast cancer. During the delivery of external beam radiation to the breast, leakage, scattered x-rays from the patient and the linear accelerator also expose healthy tissues and organs outside of the breast, thereby increasing the patient's whole-body dose, which then increases the chance of developing a secondary, radiation-induced cancer. Generally, there are three IntensityModulated Radiotherapy (IMRT) delivery techniques from a conventional linear accelerator; forward planned (FMLC), inverse planned 'sliding window' (DMLC), and inverse planned 'step-and-shoot' (SMLC). The goal of this study was to determine which of these three techniques delivers an optimal dose to the breast with the least chance of causing a fatal, secondary, radiation-induced cancer. A conventional, non-IMRT, 'Wedge' plan also was compared. Computerized Tomography (CT) data sets for both a large and small sized patient were used in this study. With Varian's Eclipse AAA algorithm, the organ doses specified in the revised ICRP 60 publication were used to calculate the whole-body dose. Also, an anthropomorphic phantom was irradiated with thermoluminescent dosimeters (TLD) at each organ site for measured doses. The risk coefficient from the Biological Effects of Ionizing Radiation (BEIR) VII report of 4.69 x 10-2 deaths per Gy was used to convert whole-body dose to risk of a fatal, secondary, radiation-induced cancer. The FMLC IMRT delivered superior tumor coverage over the 3D conventional plan and the inverse DMLC or SMLC treatment plans delivered clinically equivalent tumor coverage. However, the FMLC plan had the least likelihood of inadvertently causing a fatal, secondary, radiation-induced cancer compared to the inverse DMLC, SMLC, and Wedge plans.

  4. Clinical Outcomes of Intensity-Modulated Pelvic Radiation Therapy for Carcinoma of the Cervix

    International Nuclear Information System (INIS)

    Hasselle, Michael D.; Rose, Brent S.; Kochanski, Joel D.; Nath, Sameer K.; Bafana, Rounak; Yashar, Catheryn M.; Hasan, Yasmin; Roeske, John C.; Mundt, Arno J.; Mell, Loren K.

    2011-01-01

    Purpose: To evaluate disease outcomes and toxicity in cervical cancer patients treated with pelvic intensity-modulated radiation therapy (IMRT). Methods and Materials: We included all patients with Stage I-IVA cervical carcinoma treated with IMRT at three different institutions from 2000-2007. Patients treated with extended field or conventional techniques were excluded. Intensity-modulated radiation therapy plans were designed to deliver 45 Gy in 1.8-Gy daily fractions to the planning target volume while minimizing dose to the bowel, bladder, and rectum. Toxicity was graded according to the Radiation Therapy Oncology Group system. Overall survival and disease-free survival were estimated by use of the Kaplan-Meier method. Pelvic failure, distant failure, and late toxicity were estimated by use of cumulative incidence functions. Results: The study included 111 patients. Of these, 22 were treated with postoperative IMRT, 8 with IMRT followed by intracavitary brachytherapy and adjuvant hysterectomy, and 81 with IMRT followed by planned intracavitary brachytherapy. Of the patients, 63 had Stage I-IIA disease and 48 had Stage IIB-IVA disease. The median follow-up time was 27 months. The 3-year overall survival rate and the disease-free survival rate were 78% (95% confidence interval [CI], 68-88%) and 69% (95% CI, 59-81%), respectively. The 3-year pelvic failure rate and the distant failure rate were 14% (95% CI, 6-22%) and 17% (95% CI, 8-25%), respectively. Estimates of acute and late Grade 3 toxicity or higher were 2% (95% CI, 0-7%) and 7% (95% CI, 2-13%), respectively. Conclusions: Intensity-modulated radiation therapy is associated with low toxicity and favorable outcomes, supporting its safety and efficacy for cervical cancer. Prospective clinical trials are needed to evaluate the comparative efficacy of IMRT vs. conventional techniques.

  5. Optimizing patient positioning for intensity modulated radiation therapy in hippocampal-sparing whole brain radiation therapy.

    Science.gov (United States)

    Siglin, Joshua; Champ, Colin E; Vakhnenko, Yelena; Witek, Matthew E; Peng, Cheng; Zaorsky, Nicholas G; Harrison, Amy S; Shi, Wenyin

    2014-01-01

    Sparing the hippocampus during whole brain radiation therapy (WBRT) offers potential neurocognitive benefits. However, previously reported intensity modulated radiation therapy (IMRT) plans use multiple noncoplanar beams for treatment delivery. An optimized coplanar IMRT template for hippocampal-sparing WBRT would assist in clinical workflow and minimize resource utilization. In this study, we sought to determine the optimal patient position to facilitate coplanar treatment planning and delivery of hippocampal-sparing WBRT using IMRT. A variable angle, inclined board was utilized for patient positioning. An anthropomorphic phantom underwent computed tomography simulation at various head angles. The IMRT goals were designed to achieve target coverage of the brain while maintaining hippocampal dose-volume constraints designed to conform to the Radiation Therapy Oncology Group 0933 protocol. Optimal head angle was then verified using data from 8 patients comparing coplanar and noncoplanar WBRT IMRT plans. Hippocampal, hippocampal avoidance region, and whole brain mean volumes were 1.1 cm(3), 12.5 cm(3), and 1185.1 cm(3), respectively. The hippocampal avoidance region occupied 1.1% of the whole brain planning volume. For the 30-degree head angle, a 7-field coplanar IMRT plan was generated, sparing the hippocampus to a maximum dose of 14.7 Gy; D100% of the hippocampus was 7.4 Gy and mean hippocampal dose was 9.3 Gy. In comparison, for flat head positioning the hippocampal Dmax was 22.9 Gy with a D100% of 9.2 Gy and mean dose of 11.7 Gy. Target coverage and dose homogeneity was comparable with previously published noncoplanar IMRT plans. Compared with conventional supine positioning, an inclined head board at 30 degrees optimizes coplanar whole brain IMRT treatment planning. Clinically acceptable hippocampal-sparing WBRT dosimetry can be obtained using a simplified coplanar plan at a 30-degree head angle, thus obviating the need for complex and time consuming noncoplanar

  6. A treatment planning study comparing whole breast radiation therapy against conformal, IMRT and tomotherapy for accelerated partial breast irradiation

    International Nuclear Information System (INIS)

    Oliver, Mike; Chen, Jeff; Wong, Eugene; Van Dyk, Jake; Perera, Francisco

    2007-01-01

    Purpose and background: Conventional early breast cancer treatment consists of a lumpectomy followed by whole breast radiation therapy. Accelerated partial breast irradiation (APBI) is an investigational approach to post-lumpectomy radiation for early breast cancer. The purpose of this study is to compare four external beam APBI techniques, including tomotherapy, with conventional whole breast irradiation for their radiation conformity index, dose homogeneity index, and dose to organs at risk. Methods and materials: Small-field tangents, three-dimensional conformal radiation therapy, intensity-modulated radiation therapy and helical tomotherapy were compared for each of 15 patients (7 right, 8 left). One radiation conformity and two dose homogeneity indices were used to evaluate the dose to the target. The mean dose to organs at risk was also evaluated. Results: All proposed APBI techniques improved the conformity index significantly over whole breast tangents while maintaining dose homogeneity and without a significant increase in dose to organs at risk. Conclusion: The four-field IMRT plan produced the best dosimetric results; however this technique would require appropriate respiratory motion management. An alternative would be to use a four-field conformal technique that is less sensitive to the effects of respiratory motion

  7. Treatment and prognosis of patients with late rectal bleeding after intensity-modulated radiation therapy for prostate cancer

    International Nuclear Information System (INIS)

    Takemoto, Shinya; Kataoka, Hiromi; Mimura, Mikio; Shibamoto, Yuta; Ayakawa, Shiho; Nagai, Aiko; Hayashi, Akihiro; Ogino, Hiroyuki; Baba, Fumiya; Yanagi, Takeshi; Sugie, Chikao

    2012-01-01

    Radiation proctitis after intensity-modulated radiation therapy (IMRT) differs from that seen after pelvic irradiation in that this adverse event is a result of high-dose radiation to a very small area in the rectum. We evaluated the results of treatment for hemorrhagic proctitis after IMRT for prostate cancer. Between November 2004 and February 2010, 403 patients with prostate cancer were treated with IMRT at 2 institutions. Among these patients, 64 patients who developed late rectal bleeding were evaluated. Forty patients had received IMRT using a linear accelerator and 24 by tomotherapy. Their median age was 72 years. Each patient was assessed clinically and/or endoscopically. Depending on the severity, steroid suppositories or enemas were administered up to twice daily and Argon plasma coagulation (APC) was performed up to 3 times. Response to treatment was evaluated using the Rectal Bleeding Score (RBS), which is the sum of Frequency Score (graded from 1 to 3 by frequency of bleeding) and Amount Score (graded from 1 to 3 by amount of bleeding). Stoppage of bleeding over 3 months was scored as RBS 1. The median follow-up period for treatment of rectal bleeding was 35 months (range, 12–69 months). Grade of bleeding was 1 in 31 patients, 2 in 26, and 3 in 7. Nineteen of 45 patients (42%) observed without treatment showed improvement and bleeding stopped in 17 (38%), although mean RBS did not change significantly. Eighteen of 29 patients (62%) treated with steroid suppositories or enemas showed improvement (mean RBS, from 4.1 ± 1.0 to 3.0 ± 1.8, p = 0.003) and bleeding stopped in 9 (31%). One patient treated with steroid enema 0.5-2 times a day for 12 months developed septic shock and died of multiple organ failure. All 12 patients treated with APC showed improvement (mean RBS, 4.7 ± 1.2 to 2.3 ± 1.4, p < 0.001) and bleeding stopped in 5 (42%). After adequate periods of observation, steroid suppositories/enemas are expected to be effective. However, short

  8. Treatment and prognosis of patients with late rectal bleeding after intensity-modulated radiation therapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Takemoto Shinya

    2012-06-01

    Full Text Available Abstract Background Radiation proctitis after intensity-modulated radiation therapy (IMRT differs from that seen after pelvic irradiation in that this adverse event is a result of high-dose radiation to a very small area in the rectum. We evaluated the results of treatment for hemorrhagic proctitis after IMRT for prostate cancer. Methods Between November 2004 and February 2010, 403 patients with prostate cancer were treated with IMRT at 2 institutions. Among these patients, 64 patients who developed late rectal bleeding were evaluated. Forty patients had received IMRT using a linear accelerator and 24 by tomotherapy. Their median age was 72 years. Each patient was assessed clinically and/or endoscopically. Depending on the severity, steroid suppositories or enemas were administered up to twice daily and Argon plasma coagulation (APC was performed up to 3 times. Response to treatment was evaluated using the Rectal Bleeding Score (RBS, which is the sum of Frequency Score (graded from 1 to 3 by frequency of bleeding and Amount Score (graded from 1 to 3 by amount of bleeding. Stoppage of bleeding over 3 months was scored as RBS 1. Results The median follow-up period for treatment of rectal bleeding was 35 months (range, 12–69 months. Grade of bleeding was 1 in 31 patients, 2 in 26, and 3 in 7. Nineteen of 45 patients (42% observed without treatment showed improvement and bleeding stopped in 17 (38%, although mean RBS did not change significantly. Eighteen of 29 patients (62% treated with steroid suppositories or enemas showed improvement (mean RBS, from 4.1 ± 1.0 to 3.0 ± 1.8, p = 0.003 and bleeding stopped in 9 (31%. One patient treated with steroid enema 0.5-2 times a day for 12 months developed septic shock and died of multiple organ failure. All 12 patients treated with APC showed improvement (mean RBS, 4.7 ± 1.2 to 2.3 ± 1.4, p  Conclusions After adequate periods of observation, steroid suppositories

  9. Predictive factors for acute radiation pneumonitis in postoperative intensity modulated radiation therapy and volumetric modulated arc therapy of esophageal cancer

    OpenAIRE

    Zhao, Yaqin; Chen, Lu; Zhang, Shu; Wu, Qiang; Jiang, Xiaoqin; Zhu, Hong; Wang, Jin; Li, Zhiping; Xu, Yong; Zhang, Ying Jie; Bai, Sen; Xu, Feng

    2015-01-01

    Background Radiation pneumonitis (RP) is a common side reaction in radiotherapy for esophageal cancer. There are few reports about RP in esophageal cancer patients receiving postoperative intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). This study aims to analyze clinical or dosimetric factors associated with RP, and provides data for radiotherapy planning. Methods We reviewed 68 postoperative esophageal cancer patients who were treated with radiothera...

  10. Simple tool for prediction of parotid gland sparing in intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Gensheimer, Michael F. [Department of Radiation Oncology, University of Washington Medical Center, Seattle, WA (United States); Hummel-Kramer, Sharon M., E-mail: sharonhummel@comcast.net [Department of Radiation Oncology, VA Puget Sound Health Care System, Seattle, WA (United States); Cain, David; Quang, Tony S. [Department of Radiation Oncology, VA Puget Sound Health Care System, Seattle, WA (United States)

    2015-10-01

    Sparing one or both parotid glands is a key goal when planning head and neck cancer radiation treatment. If the planning target volume (PTV) overlaps one or both parotid glands substantially, it may not be possible to achieve adequate gland sparing. This finding results in physicians revising their PTV contours after an intensity-modulated radiation therapy (IMRT) plan has been run and reduces workflow efficiency. We devised a simple formula for predicting mean parotid gland dose from the overlap of the parotid gland and isotropically expanded PTV contours. We tested the tool using 44 patients from 2 institutions and found agreement between predicted and actual parotid gland doses (mean absolute error = 5.3 Gy). This simple method could increase treatment planning efficiency by improving the chance that the first plan presented to the physician will have optimal parotid gland sparing.

  11. Simple tool for prediction of parotid gland sparing in intensity-modulated radiation therapy.

    Science.gov (United States)

    Gensheimer, Michael F; Hummel-Kramer, Sharon M; Cain, David; Quang, Tony S

    2015-01-01

    Sparing one or both parotid glands is a key goal when planning head and neck cancer radiation treatment. If the planning target volume (PTV) overlaps one or both parotid glands substantially, it may not be possible to achieve adequate gland sparing. This finding results in physicians revising their PTV contours after an intensity-modulated radiation therapy (IMRT) plan has been run and reduces workflow efficiency. We devised a simple formula for predicting mean parotid gland dose from the overlap of the parotid gland and isotropically expanded PTV contours. We tested the tool using 44 patients from 2 institutions and found agreement between predicted and actual parotid gland doses (mean absolute error = 5.3 Gy). This simple method could increase treatment planning efficiency by improving the chance that the first plan presented to the physician will have optimal parotid gland sparing. Published by Elsevier Inc.

  12. Determining appropriate timing of adaptive radiation therapy for nasopharyngeal carcinoma during intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Huang, Huixian; Lu, Heming; Feng, Guosheng; Jiang, Hailan; Chen, Jiaxin; Cheng, Jinjian; Pang, Qiang; Lu, Zhiping; Gu, Junzhao; Peng, Luxing; Deng, Shan; Mo, Ying; Wu, Danling; Wei, Yinglin

    2015-01-01

    To determine appropriate timing of an adaptive radiation therapy (ART) replan by evaluating anatomic and dosimetric changes of target volumes and organs at risk (OARs) during intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC). Nineteen NPC patients were recruited. Each patient had repeat computed tomography (CT) scans after each five fractions and at treatment completion. Automatic re-contouring the targets and OARs by using deformable registration algorithm was conducted through CT-CT fusion. Anatomic changes were assessed by comparing the initial CT and repeated CT. Hybrid plans with re-contouring were generated and the dose-volume histograms (DVH) of the hybrid plan and the original plan were compared. Progressive volume reductions in gross target volume for primary disease (GTVnx), gross target volume for involved lymph nodes (GTVnd), and parotids were observed over time. Comparing with the original plan, each hybrid plan had no significant difference in homogeneity index (HI) for all the targets. Some parameters for planning target volumes for primary disease and high-risk clinical target volume (PTVnx and PTV1, respectively) improved significantly, notably starting from the 10th fraction. These parameters included mean dose (Dmean), dose to 95 % of the volume (D95), percentage of the volume receiving 95 % of the prescription dose (V95), and conformity index (CI) for PTVnx, and Dmean, D95, and CI for PTV1. The dosimetric parameters for PTVnd remained the same in general except for D95 and V95 which had significant improvement at specific time points; whereas for PTV2, similar trend of dosimetric changes was also observed. Dose to some OARs increased significantly at some time points. There were significant anatomic and dosimetric changes in the targets and OARs. The target dose coverage in the hybrid plans did not get worse, but overdose occurred in some critical structures. Significant dosimetric changes should be considered as a

  13. Intensity-Modulated Radiation Therapy Improves the Target Coverage Over 3-D Planning While Meeting Lung Tolerance Doses for All Patients With Malignant Pleural Mesothelioma.

    Science.gov (United States)

    Ulger, Sukran; Cetin, Eren; Catli, Serap; Sarac, Hilal; Kilic, Diclehan; Bora, Huseyin

    2017-06-01

    To investigate high conformality on target coverage and the ability on creating strict lung dose limitation of intensity-modulated radiation therapy in malignant pleural mesothelioma. Twenty-four radiation therapy plannings were evaluated and compared with dosimetric outcomes of conformal radiation therapy and intensity-modulated radiation therapy. Hemithoracal radiation therapy was performed on 12 patients with a fraction of 1.8 Gy to a total dose of 50.4 Gy. All organs at risk were contoured. Radiotherapy plannings were differed according to the technique; conformal radiation therapy was planned with conventionally combined photon-electron fields, and intensity-modulated radiation therapy was planned with 7 to 9 radiation beam angles optimized in inverse planning. Strict dose-volume constraints were applied. Intensity-modulated radiation therapy was statistically superior in target coverage and dose homogeneity (intensity-modulated radiation therapy-planning target volume 95 mean 100%; 3-dimensional conformal radiation therapy-planning target volume 95 mean 71.29%, P = .0001; intensity-modulated radiation therapy-planning target volume 105 mean 11.14%; 3-dimensional conformal radiation therapy-planning target volume 105 mean 35.69%, P = .001). The dosimetric results of the remaining lung was below the limitations on intensity-modulated radiation therapy planning data (intensity-modulated radiation therapy-lung mean dose mean 7.5 [range: 5.6%-8.5%]; intensity-modulated radiation therapy-lung V5 mean 55.55% [range: 47%-59.9%]; intensity-modulated radiation therapy-lung V20 mean 4.5% [range: 0.5%-9.5%]; intensity-modulated radiation therapy-lung V13 mean 13.43% [range: 4.2%-22.9%]). With a complex and large target volume of malignant pleural mesothelioma, intensity-modulated radiation therapy has the ability to deliver efficient tumoricidal radiation dose within the safe dose limits of the remaining lung tissue.

  14. Accommodating practical constraints for intensity-modulated radiation therapy by means of compensators

    International Nuclear Information System (INIS)

    Meyer, J.

    2001-06-01

    Radiotherapy (RT) is an important weapon in the arsenal of treatment modalities to fight cancer. It has been applied for curative and palliative management of cancer for more than a century. Intensity-modulated radiation therapy (IMRT) is a specialised RT treatment technique, which is on the verge of being routinely implemented in clinical environments within the National Health Service. In contrast to the uniform beams used for traditional RT, the aim of IMRT is to modulate the intensity of a set of high-energy photon beams in such a way that the dose can be tailored to the shape of the designated region to be treated, whilst at the same time sparing surrounding healthy tissues and critical organs. Because of normal tissue avoidance and the ability to escalate dose, acute radiation toxicity in IMRT is reduced. This thesis deals with the practical implementation of IMRT generated by means of patient specific metal compensators. Intensity modulation is achieved by placing a profiled compensator in the beam path in order to attenuate the beam differentially. A comprehensive comparison between several compensator-machining techniques, with respect to their suitability for production within a hospital workshop, is presented. The limitations associated with the selected compensator manufacturing techniques are identified and implemented as constraints in an existing inverse treatment-planning algorithm. In order to obtain the profile of a compensator, which produces a desired intensity distribution, inverse modelling of the radiation attenuation within the compensator is required. Two novel and independent approaches, based on deconvolution and system identification, respectively, are proposed to accomplish this. To compare the approach with the 'rival' state of the art beam modulation technique, theoretical and experimental examination of the modulated fields generated by manufactured compensators and multileaf collimators is presented. This comparison focused on the

  15. Matching Intensity-Modulated Radiation Therapy to an Anterior Low Neck Field

    International Nuclear Information System (INIS)

    Amdur, Robert J.; Liu, Chihray; Li, Jonathan; Mendenhall, William; Hinerman, Russell

    2007-01-01

    When using intensity-modulated radiation therapy (IMRT) to treat head and neck cancer with the primary site above the level of the larynx, there are two basic options for the low neck lymphatics: to treat the entire neck with IMRT, or to match the IMRT plan to a conventional anterior 'low neck' field. In view of the potential advantages of using a conventional low neck field, it is important to look for ways to minimize or manage the problems of matching IMRT to a conventional radiotherapy field. Treating the low neck with a single anterior field and the standard larynx block decreases the dose to the larynx and often results in a superior IMRT plan at the primary site. The purpose of this article is to review the most applicable studies and to discuss our experience with implementing a technique that involves moving the position of the superior border of the low neck field several times during a single treatment fraction

  16. Accommodating practical constraints for intensity-modulated radiation therapy by means of compensators

    CERN Document Server

    Meyer, J

    2001-01-01

    intensity distribution, inverse modelling of the radiation attenuation within the compensator is required. Two novel and independent approaches, based on deconvolution and system identification, respectively, are proposed to accomplish this. To compare the approach with the 'rival' state of the art beam modulation technique, theoretical and experimental examination of the modulated fields generated by manufactured compensators and multileaf collimators is presented. This comparison focused on the achievable resolution of the intensity modulated beams in lateral and longitudinal directions. To take into account the characteristics of a clinical environment, a comprehensive study has been carried out to investigate the suitability of the most common commercially available treatment couch systems for their suitability for IMRT treatments. In this context, an original rule based advisory system has been developed to alert the operator of any potential collision of the beam with the moveable supporting structures ...

  17. Helical tomo-therapy in the anal canal cancer: dosimetric comparison with conformal radiotherapy with intensity modulation and classical conformal radiotherapy

    International Nuclear Information System (INIS)

    Ozsahin, M.; Ugurluer, G.; Ballerini, G.; Letenneur, G.; Zouhair, A.; Mirimanoff, R.O.

    2009-01-01

    A dosimetry comparison was made between helical tomo-therapy, I.M.R.T. and classical conformal three dimensional radiotherapy for twelve first patients that received a image guided radiotherapy, the toxicity was tackled with a minimum follow-up of fourteen months. In conclusion, the CT-guided radiotherapy allows to save organs at risks superior to I.M.R.T. and conformal radiotherapy and a best homogeneity in the target volume. the toxicity is moderated and the break time is limited. (N.C.)

  18. RADIATION THERAPY COMMUNICATION-REIRRADIATION OF A NASAL TUMOR IN A BRACHYCEPHALIC DOG USING INTENSITY MODULATED RADIATION THERAPY.

    Science.gov (United States)

    Rancilio, Nicholas J; Custead, Michelle R; Poulson, Jean M

    2016-09-01

    A 5-year-old spayed female Shih Tzu was referred for evaluation of a nasal transitional carcinoma. A total lifetime dose of 117 Gy was delivered to the intranasal mass in three courses over nearly 2 years using fractionated intensity modulated radiation therapy (IMRT) to spare normal tissues. Clinically significant late normal tissue side effects were limited to bilaterally diminished tear production. The patient died of metastatic disease progression 694 days after completion of radiation therapy course 1. This case demonstrates that retreatment with radiation therapy to high lifetime doses for recurrent local disease may be well tolerated with IMRT. © 2016 American College of Veterinary Radiology.

  19. [Intensity modulated radiation therapy for patients with gynecological malignancies after hysterectomy and chemotherapy/radiotherapy].

    Science.gov (United States)

    Chen, Zhen-yun; Ma, Yue-bing; Sheng, Xiu-gui; Zhang, Xiao-ling; Xue, Li; Song, Qu-qing; Liu, Nai-fu; Miao, Hua-qin

    2007-04-01

    To investigate the value of intensity modulated radiation therapy (IMRT) for patient with gynecological malignancies after treatment of hysterectomy and chemotherapy/radiotherapy. All 32 patients with cervical or endometrial cancer after hysterectomy received full course IMRT after 1 to 3 cycles of chemotherapy (Karnofsky performance status(KPS) > or =70). Seventeen of these patients underwent postoperative preventive irradiation and the other 15 patients were pelvic wall recurrence and/or retroperitoneal lymph node metastasis, though postoperative radiotherapy and/or chemotherapy had been given after operation. The median dose delivered to the PTV was 56.8 Gy for preventive irradiation, and 60.6 Gy for pelvic wall recurrence or retroperioneal lymph node metastasis irradiation. It was required that 90% of iso-dose curve could covere more than 99% of GTV. However, The mean dose irradiated to small intestine, bladder, rectum, kidney and spinal cord was 21.3 Gy, 37.8 Gy, 35.3 Gy, 8.5 Gy, 22.1 Gy, respectively. Fourteen patients presented grade I (11 patients) or II (3 patients) digestive tract side-effects, Five patients developed grade I or II bone marrow depression. Twelve patients had grade I skin reaction. The overall 1-year survival rate was 100%. The 2- and 3- year survival rate for preventive irradiation were both 100%, but which was 5/7 and 3/6 for the patients with pelvic wall recurrence or retroperioneal lymph node metastasis. Intensity modulated radiation therapy can provide a better dose distribution than traditional radiotherapy for both prevention and pelvic wall recurrence or retroperioneal lymph node metastasis. The toxicity is tolerable. The adjacent organs at risk can well be protected.

  20. Intensity Modulated Proton Therapy Versus Intensity Modulated Photon Radiation Therapy for Oropharyngeal Cancer: First Comparative Results of Patient-Reported Outcomes

    International Nuclear Information System (INIS)

    Sio, Terence T.; Lin, Huei-Kai; Shi, Qiuling; Gunn, G. Brandon; Cleeland, Charles S.; Lee, J. Jack; Hernandez, Mike; Blanchard, Pierre; Thaker, Nikhil G.; Phan, Jack; Rosenthal, David I.; Garden, Adam S.; Morrison, William H.; Fuller, C. David; Mendoza, Tito R.; Mohan, Radhe; Wang, Xin Shelley; Frank, Steven J.

    2016-01-01

    Purpose: We hypothesized that patients with oropharyngeal cancer treated with intensity modulated proton therapy (IMPT) would have lower symptom burdens, as measured by patient-reported outcome (PRO) surveys, than patients treated with intensity modulated photon therapy (IMRT). Methods and Materials: Patients were treated for oropharyngeal cancer from 2006 to 2015 through prospective registries with concurrent chemotherapy and IMPT or chemotherapy and IMRT and completed the MD Anderson Symptom Inventory for Head and Neck Cancer (MDASI-HN) module at various times before treatment (baseline), during treatment (acute phase), within the first 3 months after treatment (subacute phase), and afterward (chronic phase). Individual symptoms and the top 5 and top 11 most severe symptoms were summarized and compared between the radiation therapy modalities. Results: PRO data were collected and analyzed from 35 patients treated with chemotherapy and IMPT and from 46 treated with chemotherapy and IMRT. The baseline symptom burdens were similar between both groups. The overall top 5 symptoms were food taste problems (mean score 4.91 on a 0-10 scale), dry mouth (4.49), swallowing/chewing difficulties (4.26), lack of appetite (4.08), and fatigue (4.00). Among the top 11 symptoms, changes in taste and appetite during the subacute and chronic phases favored IMPT (all P<.048). No differences in symptom burden were detected between modalities during the acute and chronic phases by top-11 symptom scoring. During the subacute phase, the mean (±standard deviation) top 5 MDASI scores were 5.15 ± 2.66 for IMPT versus 6.58 ± 1.98 for IMRT (P=.013). Conclusions: According to the MDASI-HN, symptom burden was lower among the IMPT patients than among the IMRT patients during the subacute recovery phase after treatment. A prospective randomized clinical trial is underway to define the value of IMPT for the management of head and neck tumors.

  1. Intensity Modulated Proton Therapy Versus Intensity Modulated Photon Radiation Therapy for Oropharyngeal Cancer: First Comparative Results of Patient-Reported Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Sio, Terence T. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Radiation Oncology, Mayo Clinic, Scottsdale, Arizona (United States); Lin, Huei-Kai; Shi, Qiuling [Department of Symptom Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Gunn, G. Brandon [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Cleeland, Charles S. [Department of Symptom Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Lee, J. Jack; Hernandez, Mike [Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Blanchard, Pierre; Thaker, Nikhil G.; Phan, Jack; Rosenthal, David I.; Garden, Adam S.; Morrison, William H.; Fuller, C. David [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Mendoza, Tito R. [Department of Symptom Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Mohan, Radhe [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Wang, Xin Shelley [Department of Symptom Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Frank, Steven J., E-mail: sjfrank@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2016-07-15

    Purpose: We hypothesized that patients with oropharyngeal cancer treated with intensity modulated proton therapy (IMPT) would have lower symptom burdens, as measured by patient-reported outcome (PRO) surveys, than patients treated with intensity modulated photon therapy (IMRT). Methods and Materials: Patients were treated for oropharyngeal cancer from 2006 to 2015 through prospective registries with concurrent chemotherapy and IMPT or chemotherapy and IMRT and completed the MD Anderson Symptom Inventory for Head and Neck Cancer (MDASI-HN) module at various times before treatment (baseline), during treatment (acute phase), within the first 3 months after treatment (subacute phase), and afterward (chronic phase). Individual symptoms and the top 5 and top 11 most severe symptoms were summarized and compared between the radiation therapy modalities. Results: PRO data were collected and analyzed from 35 patients treated with chemotherapy and IMPT and from 46 treated with chemotherapy and IMRT. The baseline symptom burdens were similar between both groups. The overall top 5 symptoms were food taste problems (mean score 4.91 on a 0-10 scale), dry mouth (4.49), swallowing/chewing difficulties (4.26), lack of appetite (4.08), and fatigue (4.00). Among the top 11 symptoms, changes in taste and appetite during the subacute and chronic phases favored IMPT (all P<.048). No differences in symptom burden were detected between modalities during the acute and chronic phases by top-11 symptom scoring. During the subacute phase, the mean (±standard deviation) top 5 MDASI scores were 5.15 ± 2.66 for IMPT versus 6.58 ± 1.98 for IMRT (P=.013). Conclusions: According to the MDASI-HN, symptom burden was lower among the IMPT patients than among the IMRT patients during the subacute recovery phase after treatment. A prospective randomized clinical trial is underway to define the value of IMPT for the management of head and neck tumors.

  2. Spinal cordd biological safety comparison of intensity modulated radiotherapy and conventional radiation therapy

    International Nuclear Information System (INIS)

    Xilinbaoleri; Xu Wanlong; Chen Gang; Liu Hao; Wang Ruozheng; Bai Jingping

    2010-01-01

    Objective: To compare the spine intensity modulated radiation therapy (IMRT) and the conventional radiation therapy on the beagle spinal cord neurons, in order to prove the biological safety of IMRT of the spinal cord. Methods: Twelve selected purebred beagles were randomly divided into 2 groups. A beagle clinical model of tumor was mimiced in the ninth and tenth thoracic vertebrae. Then the beagles were irradiated by 2 different models of intensity modulated radiotherapy and conventional radiation therapy, with the total irradiation doses of 50 and 70 Gy. The samples of spinal cord were taken out from the same position of the nine and tenth thoracic vertebrae at the third month after radiation.All the samples were observed by the electron microscope, and the Fas and HSP70 expression in spinal cord neurons were evaluated by immunohistochemistry method. Terminal deoxynucleatidyl transferase mediated dUTP nick and labeling (TUNEL) technique was used to examine the apoptotic cells in the spinal cord. Results: The neurons in the spinal cord of IMRT group were mainly reversible injury, and those in the conventional radiation therapy were mainly apoptosis. Compared with the conventional radiation therapy group [50 Gy group, (7.3 ± 1.1)%; 70 Gy group, (11.3 ± 1.4)%], the apoptosis rate of the spinal cord neurons of the intensity modulated radiotherapy group [50 Gy group, (1.2 ± 0.7)%; 70 Gy group (2.5 ± 0.8)%] was much lower[(50 Gy group, t=0.022, P<0.05; 70 Gy group, t=0.017, P<0.05)]. The expression levels of Fas in the IMPT group (50 Gy group, 4.6 ± 0.8; 70 Gy group, 7.4 ± 1.1) were also much lowerthan those in the other group (50 Gy group, 15.1 ± 6.4; 70 Gy group, 19.3 ± 7.6. 50 Gy group, t=0.231, P<0.05; 70 Gy group, t=0.457, P<0.05), while the expression levels of HSP70 in the IMPT group (50 Gy group, 9.1 ± 0.8; 70 Gy group, 7.3 ± 1.4)were much higher than those in the conventional radiation therapy group (50 Gy group, 2.1 ± 0.9; 70 Gy group, 1.7 ± 0

  3. Trends in intensity modulated radiation therapy use for locally advanced rectal cancer at National Comprehensive Cancer Network centers

    OpenAIRE

    Marsha Reyngold, MD, PhD; Joyce Niland, PhD; Anna ter Veer, MS; Tanios Bekaii-Saab, MD; Lily Lai, MD; Joshua E. Meyer, MD; Steven J. Nurkin, MD, MS; Deborah Schrag, MD, MPH; John M. Skibber, MD, FACS; Al B. Benson, MD; Martin R. Weiser, MD; Christopher H. Crane, MD; Karyn A. Goodman, MD, MS

    2018-01-01

    Purpose: Intensity modulated radiation therapy (IMRT) has been rapidly incorporated into clinical practice because of its technological advantages over 3-dimensional conformal radiation therapy (CRT). We characterized trends in IMRT utilization in trimodality treatment of locally advanced rectal cancer at National Comprehensive Cancer Network cancer centers between 2005 and 2011. Methods and materials: Using the prospective National Comprehensive Cancer Network Colorectal Cancer Database, ...

  4. Intensity-modulated radiation therapy to bilateral lower limb extremities concurrently: a planning case study

    Energy Technology Data Exchange (ETDEWEB)

    Fitzgerald, Emma, E-mail: emmafitz1390@gmail.com; Miles, Wesley; Fenton, Paul; Frantzis, Jim [Radiation Oncology, Epworth HealthCare, Victoria (Australia)

    2014-09-15

    Non-melanomatous skin cancers represent 80% of all newly diagnosed cancers in Australia with basal cell carcinoma (BCC) and squamous cell carcinoma (SCC) being the most common. A previously healthy 71-year-old woman presented with widespread and tender superficial skin cancers on the lower bilateral limbs. External beam radiation therapy through the use of intensity-modulated radiation therapy (IMRT) was employed as the treatment modality of choice as this technique provides conformal dose distribution to a three-dimensional treatment volume while reducing toxicity to surrounding tissues. The patient was prescribed a dose of 60 Gy to the planning target volume (PTV) with 1.0 cm bolus over the ventral surface of each limb. The beam arrangement consisted of six treatment fields that avoided entry and exit through the contralateral limb. The treatment plans met the International Commission on Radiation Units and Measurements (ICRU) guidelines and produced highly conformal dosimetric results. Skin toxicity was measured against the National Cancer Institute: Common Terminology Criteria for Adverse Events (NCI: CTCAE) version 3. A well-tolerated treatment was delivered with excellent results given the initial extent of the disease. This case study has demonstrated the feasibility and effectiveness of IMRT for skin cancers as an alternative to surgery and traditional superficial radiation therapy, utilising a complex PTV of the extremities for patients with similar presentations.

  5. Intensity-modulated radiation therapy to bilateral lower limb extremities concurrently: a planning case study

    International Nuclear Information System (INIS)

    Fitzgerald, Emma; Miles, Wesley; Fenton, Paul; Frantzis, Jim

    2014-01-01

    Non-melanomatous skin cancers represent 80% of all newly diagnosed cancers in Australia with basal cell carcinoma (BCC) and squamous cell carcinoma (SCC) being the most common. A previously healthy 71-year-old woman presented with widespread and tender superficial skin cancers on the lower bilateral limbs. External beam radiation therapy through the use of intensity-modulated radiation therapy (IMRT) was employed as the treatment modality of choice as this technique provides conformal dose distribution to a three-dimensional treatment volume while reducing toxicity to surrounding tissues. The patient was prescribed a dose of 60 Gy to the planning target volume (PTV) with 1.0 cm bolus over the ventral surface of each limb. The beam arrangement consisted of six treatment fields that avoided entry and exit through the contralateral limb. The treatment plans met the International Commission on Radiation Units and Measurements (ICRU) guidelines and produced highly conformal dosimetric results. Skin toxicity was measured against the National Cancer Institute: Common Terminology Criteria for Adverse Events (NCI: CTCAE) version 3. A well-tolerated treatment was delivered with excellent results given the initial extent of the disease. This case study has demonstrated the feasibility and effectiveness of IMRT for skin cancers as an alternative to surgery and traditional superficial radiation therapy, utilising a complex PTV of the extremities for patients with similar presentations

  6. Extrapleural pneumonectomy, photodynamic therapy and intensity modulated radiation therapy for the treatment of malignant pleural mesothelioma.

    Science.gov (United States)

    Du, Kevin L; Both, Stefan; Friedberg, Joseph S; Rengan, Ramesh; Hahn, Stephen M; Cengel, Keith A

    2010-09-01

    Intensity modulated radiation therapy (IMRT) has recently been proposed for the treatment of malignant pleural mesothelioma (MPM). Here, we describe our experience with a multimodality approach for the treatment of mesothelioma, incorporating extrapleural pneumonectomy, intraoperative photodynamic therapy and postoperative hemithoracic IMRT. From 2004-2007, we treated 11 MPM patients with hemithoracic IMRT, 7 of whom had undergone porfimer sodium-mediated PDT as an intraoperative adjuvant to surgical debulking. The median radiation dose to the planning treatment volume (PTV) ranged from 45.4-54.5 Gy. For the contralateral lung, V20 ranged from 1.4-28.5%, V5 from 42-100% and MLD from 6.8-16.5 Gy. In our series, 1 patient experienced respiratory failure secondary to radiation pneumonitis that did not require mechanical ventilation. Multimodality therapy combining surgery with increased doses of radiation using IMRT, and newer treatment modalities such as PDT , appears safe. Future prospective analysis will be needed to demonstrate efficacy of this approach in the treatment of malignant mesothelioma. Efforts to reduce lung toxicity and improve dose delivery are needed and provide the promise of improved local control and quality of life in a carefully chosen multidisciplinary approach.

  7. Role of beam orientation optimization in intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Pugachev, Andrei; Li, Jonathan G.; Boyer, Arthur L.; Hancock, Steven L.; Le, Quynh-Thu; Donaldson, Sarah S.; Lei Xing

    2001-01-01

    Purpose: To investigate the role of beam orientation optimization in intensity-modulated radiation therapy (IMRT) and to examine the potential benefits of noncoplanar intensity-modulated beams. Methods and Materials: A beam orientation optimization algorithm was implemented. For this purpose, system variables were divided into two groups: beam position (gantry and table angles) and beam profile (beamlet weights). Simulated annealing was used for beam orientation optimization and the simultaneous iterative inverse treatment planning algorithm (SIITP) for beam intensity profile optimization. Three clinical cases were studied: a localized prostate cancer, a nasopharyngeal cancer, and a paraspinal tumor. Nine fields were used for all treatments. For each case, 3 types of treatment plan optimization were performed: (1) beam intensity profiles were optimized for 9 equiangular spaced coplanar beams; (2) orientations and intensity profiles were optimized for 9 coplanar beams; (3) orientations and intensity profiles were optimized for 9 noncoplanar beams. Results: For the localized prostate case, all 3 types of optimization described above resulted in dose distributions of a similar quality. For the nasopharynx case, optimized noncoplanar beams provided a significant gain in the gross tumor volume coverage. For the paraspinal case, orientation optimization using noncoplanar beams resulted in better kidney sparing and improved gross tumor volume coverage. Conclusion: The sensitivity of an IMRT treatment plan with respect to the selection of beam orientations varies from site to site. For some cases, the choice of beam orientations is important even when the number of beams is as large as 9. Noncoplanar beams provide an additional degree of freedom for IMRT treatment optimization and may allow for notable improvement in the quality of some complicated plans

  8. Three-Dimensional Dosimetric Validation of a Magnetic Resonance Guided Intensity Modulated Radiation Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Rankine, Leith J., E-mail: Leith_Rankine@med.unc.edu [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Department of Radiation Oncology, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Mein, Stewart [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Cai, Bin; Curcuru, Austen [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Juang, Titania; Miles, Devin [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Mutic, Sasa; Wang, Yuhe [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Oldham, Mark [Medical Physics Graduate Program, Duke University, Durham, North Carolina (United States); Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Li, H. Harold, E-mail: hli@radonc.wustl.edu [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States)

    2017-04-01

    Purpose: To validate the dosimetric accuracy of a commercially available magnetic resonance guided intensity modulated radiation therapy (MRgIMRT) system using a hybrid approach: 3-dimensional (3D) measurements and Monte Carlo calculations. Methods and Materials: We used PRESAGE radiochromic plastic dosimeters with remote optical computed tomography readout to perform 3D high-resolution measurements, following a novel remote dosimetry protocol. We followed the intensity modulated radiation therapy commissioning recommendations of American Association of Physicists in Medicine Task Group 119, adapted to incorporate 3D data. Preliminary tests (“AP” and “3D-Bands”) were delivered to 9.5-cm usable diameter cylindrical PRESAGE dosimeters to validate the treatment planning system (TPS) for nonmodulated deliveries; assess the sensitivity, uniformity, and rotational symmetry of the PRESAGE dosimeters; and test the robustness of the remote dosimetry protocol. Following this, 4 clinical MRgIMRT plans (“MultiTarget,” “Prostate,” “Head/Neck,” and “C-Shape”) were measured using 13-cm usable diameter PRESAGE dosimeters. For all plans, 3D-γ (3% or 3 mm global, 10% threshold) passing rates were calculated and 3D-γ maps were examined. Point doses were measured with an IBA-CC01 ionization chamber for validation of absolute dose. Finally, by use of an in-house-developed, GPU-accelerated Monte Carlo algorithm (gPENELOPE), we independently calculated dose for all 6 Task Group 119 plans and compared against the TPS. Results: For PRESAGE measurements, 3D-γ analysis yielded passing rates of 98.7%, 99.2%, 98.5%, 98.0%, 99.2%, and 90.7% for AP, 3D-Bands, MultiTarget, Prostate, Head/Neck, and C-Shape, respectively. Ion chamber measurements were within an average of 0.5% (±1.1%) from the TPS dose. Monte Carlo calculations demonstrated good agreement with the TPS, with a mean 3D-γ passing rate of 98.5% ± 1.9% using a stricter 2%/2-mm criterion. Conclusions: We

  9. Fatal pneumonitis associated with intensity-modulated radiation therapy for mesothelioma

    International Nuclear Information System (INIS)

    Allen, Aaron M.; Czerminska, Maria; Jaenne, Pasi A.; Sugarbaker, David J.; Bueno, Raphael; Harris, Jay R.; Court, Laurence; Baldini, Elizabeth H.

    2006-01-01

    Purpose: To describe the initial experience at Dana-Farber Cancer Institute/Brigham and Women's Hospital with intensity-modulated radiation therapy (IMRT) as adjuvant therapy after extrapleural pneumonectomy (EPP) and adjuvant chemotherapy. Methods and Materials: The medical records of patients treated with IMRT after EPP and adjuvant chemotherapy were retrospectively reviewed. IMRT was given to a dose of 54 Gy to the clinical target volume in 1.8 Gy daily fractions. Treatment was delivered with a dynamic multileaf collimator using a sliding window technique. Eleven of 13 patients received heated intraoperative cisplatin chemotherapy (225 mg/m 2 ). Two patients received neoadjuvant intravenous cisplatin/pemetrexed, and 10 patients received adjuvant cisplatin/pemetrexed chemotherapy after EPP but before radiation therapy. All patients received at least 2 cycles of intravenous chemotherapy. The contralateral lung was limited to a V20 (volume of lung receiving 20 Gy or more) of 20% and a mean lung dose (MLD) of 15 Gy. All patients underwent fluorodeoxyglucose positron emission tomography (FDG-PET) for staging, and any FDG-avid areas in the hemithorax were given a simultaneous boost of radiotherapy to 60 Gy. Statistical comparisons were done using two-sided t test. Results: Thirteen patients were treated with IMRT from December 2004 to September 2005. Six patients developed fatal pneumonitis after treatment. The median time from completion of IMRT to the onset of radiation pneumonitis was 30 days (range 5-57 days). Thirty percent of patients (4 of 13) developed acute Grade 3 nausea and vomiting. One patient developed acute Grade 3 thrombocytopenia. The median V20, MLD, and V5 (volume of lung receiving 5 Gy or more) for the patients who developed pneumonitis was 17.6% (range, 15.3-22.3%), 15.2 Gy (range, 13.3-17 Gy), and 98.6% (range, 81-100%), respectively, as compared with 10.9% (range, 5.5-24.7%) (p = 0.08), 12.9 Gy (range, 8.7-16.9 Gy) (p = 0.07), and 90% (range, 66

  10. Fatal pneumonitis associated with intensity-modulated radiation therapy for mesothelioma.

    Science.gov (United States)

    Allen, Aaron M; Czerminska, Maria; Jänne, Pasi A; Sugarbaker, David J; Bueno, Raphael; Harris, Jay R; Court, Laurence; Baldini, Elizabeth H

    2006-07-01

    To describe the initial experience at Dana-Farber Cancer Institute/Brigham and Women's Hospital with intensity-modulated radiation therapy (IMRT) as adjuvant therapy after extrapleural pneumonectomy (EPP) and adjuvant chemotherapy. The medical records of patients treated with IMRT after EPP and adjuvant chemotherapy were retrospectively reviewed. IMRT was given to a dose of 54 Gy to the clinical target volume in 1.8 Gy daily fractions. Treatment was delivered with a dynamic multileaf collimator using a sliding window technique. Eleven of 13 patients received heated intraoperative cisplatin chemotherapy (225 mg/m(2)). Two patients received neoadjuvant intravenous cisplatin/pemetrexed, and 10 patients received adjuvant cisplatin/pemetrexed chemotherapy after EPP but before radiation therapy. All patients received at least 2 cycles of intravenous chemotherapy. The contralateral lung was limited to a V20 (volume of lung receiving 20 Gy or more) of 20% and a mean lung dose (MLD) of 15 Gy. All patients underwent fluorodeoxyglucose positron emission tomography (FDG-PET) for staging, and any FDG-avid areas in the hemithorax were given a simultaneous boost of radiotherapy to 60 Gy. Statistical comparisons were done using two-sided t test. Thirteen patients were treated with IMRT from December 2004 to September 2005. Six patients developed fatal pneumonitis after treatment. The median time from completion of IMRT to the onset of radiation pneumonitis was 30 days (range 5-57 days). Thirty percent of patients (4 of 13) developed acute Grade 3 nausea and vomiting. One patient developed acute Grade 3 thrombocytopenia. The median V20, MLD, and V5 (volume of lung receiving 5 Gy or more) for the patients who developed pneumonitis was 17.6% (range, 15.3-22.3%), 15.2 Gy (range, 13.3-17 Gy), and 98.6% (range, 81-100%), respectively, as compared with 10.9% (range, 5.5-24.7%) (p = 0.08), 12.9 Gy (range, 8.7-16.9 Gy) (p = 0.07), and 90% (range, 66-98.3%) (p = 0.20), respectively, for the

  11. Three-Dimensional Dosimetric Validation of a Magnetic Resonance Guided Intensity Modulated Radiation Therapy System

    International Nuclear Information System (INIS)

    Rankine, Leith J.; Mein, Stewart; Cai, Bin; Curcuru, Austen; Juang, Titania; Miles, Devin; Mutic, Sasa; Wang, Yuhe; Oldham, Mark; Li, H. Harold

    2017-01-01

    Purpose: To validate the dosimetric accuracy of a commercially available magnetic resonance guided intensity modulated radiation therapy (MRgIMRT) system using a hybrid approach: 3-dimensional (3D) measurements and Monte Carlo calculations. Methods and Materials: We used PRESAGE radiochromic plastic dosimeters with remote optical computed tomography readout to perform 3D high-resolution measurements, following a novel remote dosimetry protocol. We followed the intensity modulated radiation therapy commissioning recommendations of American Association of Physicists in Medicine Task Group 119, adapted to incorporate 3D data. Preliminary tests (“AP” and “3D-Bands”) were delivered to 9.5-cm usable diameter cylindrical PRESAGE dosimeters to validate the treatment planning system (TPS) for nonmodulated deliveries; assess the sensitivity, uniformity, and rotational symmetry of the PRESAGE dosimeters; and test the robustness of the remote dosimetry protocol. Following this, 4 clinical MRgIMRT plans (“MultiTarget,” “Prostate,” “Head/Neck,” and “C-Shape”) were measured using 13-cm usable diameter PRESAGE dosimeters. For all plans, 3D-γ (3% or 3 mm global, 10% threshold) passing rates were calculated and 3D-γ maps were examined. Point doses were measured with an IBA-CC01 ionization chamber for validation of absolute dose. Finally, by use of an in-house-developed, GPU-accelerated Monte Carlo algorithm (gPENELOPE), we independently calculated dose for all 6 Task Group 119 plans and compared against the TPS. Results: For PRESAGE measurements, 3D-γ analysis yielded passing rates of 98.7%, 99.2%, 98.5%, 98.0%, 99.2%, and 90.7% for AP, 3D-Bands, MultiTarget, Prostate, Head/Neck, and C-Shape, respectively. Ion chamber measurements were within an average of 0.5% (±1.1%) from the TPS dose. Monte Carlo calculations demonstrated good agreement with the TPS, with a mean 3D-γ passing rate of 98.5% ± 1.9% using a stricter 2%/2-mm criterion. Conclusions: We

  12. Intensity-modulated radiation therapy for pediatric medulloblastoma: early report on the reduction of ototoxicity

    International Nuclear Information System (INIS)

    Huang, Eugene; Teh, Bin S.; Strother, Douglas R.; Davis, Quillin G.; Chiu, J. Kam; Lu, Hsin H.; Carpenter, L. Steven; Mai Weiyuan; Chintagumpala, Murali M.; South, Michael; Grant, Walter H. III; Butler, E. Brian; Woo, Shiao Y.

    2002-01-01

    Purpose: The combination of cisplatin chemotherapy and radiation therapy for the treatment of medulloblastoma has been shown to cause significant ototoxicity, impairing a child's cognitive function and quality of life. Our purpose is to determine whether the new conformal technique of intensity-modulated radiation therapy (IMRT) can achieve lower rates of hearing loss by decreasing the radiation dose delivered to the cochlea and eighth cranial nerve (auditory apparatus). Patients and Methods: Twenty-six pediatric patients treated for medulloblastoma were retrospectively divided into two groups that received either conventional radiotherapy (Conventional-RT Group) or IMRT (IMRT Group). One hundred thirteen pure-tone audiograms were evaluated retrospectively, and hearing function was graded on a scale of 0 to 4 according to the Pediatric Oncology Group's toxicity criteria. Statistical analysis comparing the rates of ototoxicity was performed using Fisher's exact test with two-tailed analysis. Results: When compared to conventional radiotherapy, IMRT delivered 68% of the radiation dose to the auditory apparatus (mean dose: 36.7 vs. 54.2 Gy). Audiometric evaluation showed that mean decibel hearing thresholds of the IMRT Group were lower at every frequency compared to those of the Conventional-RT Group, despite having higher cumulative doses of cisplatin. The overall incidence of ototoxicity was lower in the IMRT Group. Thirteen percent of the IMRT Group had Grade 3 or 4 hearing loss, compared to 64% of the Conventional-RT Group (p<0.014). Conclusion: The conformal technique of IMRT delivered much lower doses of radiation to the auditory apparatus, while still delivering full doses to the desired target volume. Our findings suggest that, despite higher doses of cisplatin, and despite radiotherapy before cisplatin therapy, treatment with IMRT can achieve a lower rate of hearing loss

  13. Statistical process control analysis for patient quality assurance of intensity modulated radiation therapy

    Science.gov (United States)

    Lee, Rena; Kim, Kyubo; Cho, Samju; Lim, Sangwook; Lee, Suk; Shim, Jang Bo; Huh, Hyun Do; Lee, Sang Hoon; Ahn, Sohyun

    2017-11-01

    This study applied statistical process control to set and verify the quality assurances (QA) tolerance standard for our hospital's characteristics with the criteria standards that are applied to all the treatment sites with this analysis. Gamma test factor of delivery quality assurances (DQA) was based on 3%/3 mm. Head and neck, breast, prostate cases of intensity modulated radiation therapy (IMRT) or volumetric arc radiation therapy (VMAT) were selected for the analysis of the QA treatment sites. The numbers of data used in the analysis were 73 and 68 for head and neck patients. Prostate and breast were 49 and 152 by MapCHECK and ArcCHECK respectively. C p value of head and neck and prostate QA were above 1.0, C pml is 1.53 and 1.71 respectively, which is close to the target value of 100%. C pml value of breast (IMRT) was 1.67, data values are close to the target value of 95%. But value of was 0.90, which means that the data values are widely distributed. C p and C pml of breast VMAT QA were respectively 1.07 and 2.10. This suggests that the VMAT QA has better process capability than the IMRT QA. Consequently, we should pay more attention to planning and QA before treatment for breast Radiotherapy.

  14. Influence of intensity-modulated radiation therapy on parotid function in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Cui Tiantian; Wu Shaoxiong; Han Fei; Lu Lixia; Huang Shaomin; Deng Xiaowu; Lu Taixiang; Zhao Chong

    2009-01-01

    Objective: To evaluate the effect of intensity-modulated radiation therapy (IMRT) on parotid function in nasopharyngeal carcinoma (NPC). Methods: Eighty-three NPC patients received prima- ry IMRT between 2001 and 2003. Xerostomia before radiotherapy, at the end of radiotherapy, at 6-month, 1-, 2-,3-,4- and 5-year after radiotherapy were investigated, respectively. The relation between xerostomia and parotid dose distribution was analyzed. Results: Of all the patients, 4, 31, 31 and 17 had stage I, II, III and IV A disease, respectively. Sixteen patients received chemo-radiotherapy. The median followed-up time was 65 months. The 5-year local control and regional control rate were 96% and 95%, respectively. The 5- year overall survival rate was 80%. The mild xerostomia rate at the seven time points was 42%, 51%, 71%, 77%, 58%, 38% and 26%. The corresponding moderate xerostomia rate was 52%, 53%, 21%, 8%, 3%, 2% and 2%, respectively. No serious xerostomia was observed. The mean dose of the bilateral parotid glands was 34.34 Gy. Xerostomia at 6-month after radiotherapy was positively correlated with the mean dose of the parotid glands, and D 50 was the independent factor in predicting the xerostomia. Parotid function was well protected when the mean dose and D 50 were no more than 33 Gy and 29 Gy, respectively. Conclusions: IMRT can improve the local-regional control of NPC and protect the parotid glands from radiation-induced injury. (authors)

  15. SU-E-P-18: Intensity-Modulated Radiation Therapy for Cervical Esophageal Squamous Cell Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Bai, W; Qiao, X; Zhou, Z; Song, Y; Zhang, R; Zhen, C [The Fourth Hospital of Hebei Medical University, Shijiazhuang, Hebei (China)

    2015-06-15

    Purpose: To retrospectively analyze the outcomes and prognostic factors of cervical esophageal squamous cell carcinoma (SCC) treated with intensity modulated radiation therapy (IMRT). Methods: Thirty-seven patients with cervical esophageal SCC treated with IMRT were analyzed retrospectively. They received 54–66 Gy in 27–32 fractions. Nineteen patients received concurrent (n=12) or sequential (n=7) platinum-based two drugs chemoradiotherapy. Overall survival (OS), local control rates (LCR) and prognostic factors were evaluated. Acute toxicities and patterns of first failures were observed. Results: The median follow-up was 46 months for alive patients. The l-, 3-, 4- and 5-year OS of the all patients were 83.8%, 59.1%, 47.5% and 32.6% respectively. The median survival time was 46 months. The l-, 3-,4- and 5-year LCR were 82.9%, 63.0%, 54.5% and 54.5%, respectively. Univariate and Multivariate analysis all showed that size of GTV was an independent prognostic factor (p=0.033, p=0.039). There were no patients with Grade 3 acute radiation esophagitis and Grade 2–4 acute pneumonitis. The local failure accounted for 70.0% of all treatment-related failures. Conclusion: IMRT is safe and effective in the treatment of cervical esophageal squamous cell carcinoma. Size of GTV is an independent prognostic factor. Local failure still remains the main reason of treatment failures. The authors declare no conflicts of interest in preparing this article.

  16. A Comparison of Helical Intensity-Modulated Radiotherapy, Intensity-Modulated Radiotherapy, and 3D-Conformal Radiation Therapy for Pancreatic Cancer

    International Nuclear Information System (INIS)

    Poppe, Matthew M.; Narra, Venkat; Yue, Ning J.; Zhou Jinghao; Nelson, Carl; Jabbour, Salma K.

    2011-01-01

    We assessed dosimetric differences in pancreatic cancer radiotherapy via helical intensity-modulated radiotherapy (HIMRT), linac-based IMRT, and 3D-conformal radiation therapy (3D-CRT) with regard to successful plan acceptance and dose to critical organs. Dosimetric analysis was performed in 16 pancreatic cases that were planned to 54 Gy; both post-pancreaticoduodenectomy (n = 8) and unresected (n = 8) cases were compared. Without volume modification, plans met constraints 75% of the time with HIMRT and IMRT and 13% with 3D-CRT. There was no statistically significantly improvement with HIMRT over conventional IMRT in reducing liver V35, stomach V45, or bowel V45. HIMRT offers improved planning target volume (PTV) dose homogeneity compared with IMRT, averaging a lower maximum dose and higher volume receiving the prescription dose (D100). HIMRT showed an increased mean dose over IMRT to bowel and liver. Both HIMRT and IMRT offer a statistically significant improvement over 3D-CRT in lowering dose to liver, stomach, and bowel. The results were similar for both unresected and resected patients. In pancreatic cancer, HIMRT offers improved dose homogeneity over conventional IMRT and several significant benefits to 3D-CRT. Factors to consider before incorporating IMRT into pancreatic cancer therapy are respiratory motion, dose inhomogeneity, and mean dose.

  17. Intensity-Modulated Radiation Therapy in the Salvage of Locally Recurrent Nasopharyngeal Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Sufang [Department of Radiation Oncology, Cancer Hospital of Fujian Medical University, Fuzhou, Fujian (China); Department of Radiation Oncology, National University Cancer Institute, National University Health System, National University of Singapore (Singapore); Lin Shaojun [Department of Radiation Oncology, Cancer Hospital of Fujian Medical University, Fuzhou, Fujian (China); Tham, Ivan W.K. [Department of Radiation Oncology, National University Cancer Institute, National University Health System, National University of Singapore (Singapore); Pan Jianji; Lu Jun [Department of Radiation Oncology, Cancer Hospital of Fujian Medical University, Fuzhou, Fujian (China); Lu, Jiade J., E-mail: mdcljj@nus.edu.sg [Department of Radiation Oncology, National University Cancer Institute, National University Health System, National University of Singapore (Singapore)

    2012-06-01

    Purpose: Local recurrences of nasopharyngeal carcinoma (NPC) may be salvaged by reirradiation with conventional techniques, but with significant morbidity. Intensity-modulated radiation therapy (IMRT) may improve the therapeutic ratio by reducing doses to normal tissue. The aim of this study was to address the efficacy and toxicity profile of IMRT for a cohort of patients with locally recurrent NPC. Methods and Materials: Between August 2003 and June 2009, 70 patients with radiologic or pathologically proven locally recurrent NPC were treated with IMRT. The median time to recurrence was 30 months after the completion of conventional radiation to definitive dose. Fifty-seven percent of the tumors were classified asrT3-4. The minimum planned doses were 59.4 to 60 Gy in 1.8- to 2-Gy fractions per day to the gross disease with margins, with or without chemotherapy. Results: The median dose to the recurrent tumor was 70 Gy (range, 50-77.4 Gy). Sixty-five patients received the planned radiation therapy; 5 patients received between 50 and 60 Gy because of acute side effects. With a median follow-up time of 25 months, the rates of 2-year locoregional recurrence-free survival, disease-free survival, and overall survival were 65.8%, 65.8%, and 67.4%, respectively. Moderate to severe late toxicities were noted in 25 patients (35.7%). Eleven patients (15.7%) had posterior nasal space ulceration, 17 (24.3%) experienced cranial nerve palsies, 12 (17.1%) had trismus, and 12 (17.1%) experienced deafness. Extended disease-free interval (relative risk 2.049) and advanced T classification (relative risk 3.895) at presentation were adverse prognostic factors. Conclusion: Reirradiation with IMRT provides reasonable long-term control in patients with locally recurrent NPC.

  18. Intensity-Modulated Radiation Therapy in the Salvage of Locally Recurrent Nasopharyngeal Carcinoma

    International Nuclear Information System (INIS)

    Qiu Sufang; Lin Shaojun; Tham, Ivan W.K.; Pan Jianji; Lu Jun; Lu, Jiade J.

    2012-01-01

    Purpose: Local recurrences of nasopharyngeal carcinoma (NPC) may be salvaged by reirradiation with conventional techniques, but with significant morbidity. Intensity-modulated radiation therapy (IMRT) may improve the therapeutic ratio by reducing doses to normal tissue. The aim of this study was to address the efficacy and toxicity profile of IMRT for a cohort of patients with locally recurrent NPC. Methods and Materials: Between August 2003 and June 2009, 70 patients with radiologic or pathologically proven locally recurrent NPC were treated with IMRT. The median time to recurrence was 30 months after the completion of conventional radiation to definitive dose. Fifty-seven percent of the tumors were classified asrT3–4. The minimum planned doses were 59.4 to 60 Gy in 1.8- to 2-Gy fractions per day to the gross disease with margins, with or without chemotherapy. Results: The median dose to the recurrent tumor was 70 Gy (range, 50–77.4 Gy). Sixty-five patients received the planned radiation therapy; 5 patients received between 50 and 60 Gy because of acute side effects. With a median follow-up time of 25 months, the rates of 2-year locoregional recurrence-free survival, disease-free survival, and overall survival were 65.8%, 65.8%, and 67.4%, respectively. Moderate to severe late toxicities were noted in 25 patients (35.7%). Eleven patients (15.7%) had posterior nasal space ulceration, 17 (24.3%) experienced cranial nerve palsies, 12 (17.1%) had trismus, and 12 (17.1%) experienced deafness. Extended disease-free interval (relative risk 2.049) and advanced T classification (relative risk 3.895) at presentation were adverse prognostic factors. Conclusion: Reirradiation with IMRT provides reasonable long-term control in patients with locally recurrent NPC.

  19. Postmastectomy intensity modulated radiation therapy following immediate expander-implant reconstruction

    International Nuclear Information System (INIS)

    Koutcher, Lawrence; Ballangrud, Ase; Cordeiro, Peter G.; McCormick, Beryl; Hunt, Margie; Zee, Kimberly J. Van; Hudis, Clifford; Beal, Kathryn

    2010-01-01

    Background/purpose: To evaluate radiation plans of patients undergoing mastectomy with immediate expander-implant reconstruction followed by postmastectomy radiation therapy (PMRT). Materials/methods: We identified 41 patients from June 2004 to May 2007 who underwent mastectomy, immediate expander-implant reconstruction, and PMRT with intensity-modulated radiation therapy. We assessed chest wall (CW) coverage and volume of heart and lung irradiated. Results: In 73% of patients, all CW borders were adequately covered, and in 22%, all but 1 border were adequately covered. The total lung V 20 was 20 was 13% (range, 3-23%), and the mean heart D mean was 2.81 Gy (range, 0.53-9.60 Gy). In patients with left-sided lesions without internal mammary nodes (IMNs) treatment (n = 22), the mean lung V 20 was 12.6% and the mean heart D mean was 3.90 Gy, and in the patient with IMN treatment, the lung V 20 was 18% and heart D mean was 8.04 Gy. For right-sided lesions without IMN treatment (n = 12), the mean lung V 20 was 12.4% and the mean heart D mean was 0.90 Gy, and in patients with IMN treatment (n = 6), these numbers were 17.8% and 1.76 Gy. At a median follow-up of 29 months, the 30-month actuarial local control was 97%. Conclusions: In women undergoing immediate expander-implant reconstruction, PMRT can achieve excellent local control with acceptable heart and lung doses. These results can be achieved even when the IMN are being treated, although doses to the heart and lungs will be higher.

  20. Intensity-Modulated Radiation Therapy With Concurrent Chemotherapy as Preoperative Treatment for Localized Gastric Adenocarcinoma

    International Nuclear Information System (INIS)

    Chakravarty, Twisha; Crane, Christopher H.; Ajani, Jaffer A.; Mansfield, Paul F.; Briere, Tina M.; Beddar, A. Sam; Mok, Henry; Reed, Valerie K.; Krishnan, Sunil; Delclos, Marc E.; Das, Prajnan

    2012-01-01

    Purpose: The goal of this study was to evaluate dosimetric parameters, acute toxicity, pathologic response, and local control in patients treated with preoperative intensity-modulated radiation therapy (IMRT) and concurrent chemotherapy for localized gastric adenocarcinoma. Methods: Between November 2007 and April 2010, 25 patients with localized gastric adenocarcinoma were treated with induction chemotherapy, followed by preoperative IMRT and concurrent chemotherapy and, finally, surgical resection. The median radiation therapy dose was 45 Gy. Concurrent chemotherapy was 5-fluorouracil and oxaliplatin in 18 patients, capecitabine in 3, and other regimens in 4. Subsequently, resection was performed with total gastrectomy in 13 patients, subtotal gastrectomy in 7, and other surgeries in 5. Results: Target coverage, expressed as the ratio of the minimum dose received by 99% of the planning target volume to the prescribed dose, was a median of 0.97 (range, 0.92–1.01). The median V 30 (percentage of volume receiving at least 30 Gy) for the liver was 26%; the median V 20 (percentage of volume receiving at least 20 Gy) for the right and left kidneys was 14% and 24%, respectively; and the median V 40 (percentage of volume receiving at least 40 Gy) for the heart was 18%. Grade 3 acute toxicity developed in 14 patients (56%), including dehydration in 10, nausea in 8, and anorexia in 5. Grade 4 acute toxicity did not develop in any patient. There were no significant differences in the rates of acute toxicity, hospitalization, or feeding tube use in comparison to those in a group of 50 patients treated with preoperative three-dimensional conformal radiation therapy with concurrent chemotherapy. R0 resection was obtained in 20 patients (80%), and pathologic complete response occurred in 5 (20%). Conclusions: Preoperative IMRT for gastric adenocarcinoma was well tolerated, accomplished excellent target coverage and normal structure sparing, and led to appropriate pathologic

  1. Expert Consensus Contouring Guidelines for Intensity Modulated Radiation Therapy in Esophageal and Gastroesophageal Junction Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Abraham J., E-mail: wua@mskcc.org [Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Bosch, Walter R. [Washington University, St. Louis, Missouri (United States); Chang, Daniel T. [Stanford Cancer Institute, Stanford, California (United States); Hong, Theodore S. [Massachusetts General Hospital, Boston, Massachusetts (United States); Jabbour, Salma K. [Rutgers Cancer Institute of New Jersey, New Brunswick, New Jersey (United States); Kleinberg, Lawrence R. [Johns Hopkins Medical Center, Baltimore, Maryland (United States); Mamon, Harvey J. [Brigham and Women' s Hospital, Boston, Massachusetts (United States); Thomas, Charles R. [Knight Cancer Institute, Oregon Health & Sciences University, Portland, Oregon (United States); Goodman, Karyn A. [Memorial Sloan-Kettering Cancer Center, New York, New York (United States)

    2015-07-15

    Purpose/Objective(s): Current guidelines for esophageal cancer contouring are derived from traditional 2-dimensional fields based on bony landmarks, and they do not provide sufficient anatomic detail to ensure consistent contouring for more conformal radiation therapy techniques such as intensity modulated radiation therapy (IMRT). Therefore, we convened an expert panel with the specific aim to derive contouring guidelines and generate an atlas for the clinical target volume (CTV) in esophageal or gastroesophageal junction (GEJ) cancer. Methods and Materials: Eight expert academically based gastrointestinal radiation oncologists participated. Three sample cases were chosen: a GEJ cancer, a distal esophageal cancer, and a mid-upper esophageal cancer. Uniform computed tomographic (CT) simulation datasets and accompanying diagnostic positron emission tomographic/CT images were distributed to each expert, and the expert was instructed to generate gross tumor volume (GTV) and CTV contours for each case. All contours were aggregated and subjected to quantitative analysis to assess the degree of concordance between experts and to generate draft consensus contours. The panel then refined these contours to generate the contouring atlas. Results: The κ statistics indicated substantial agreement between panelists for each of the 3 test cases. A consensus CTV atlas was generated for the 3 test cases, each representing common anatomic presentations of esophageal cancer. The panel agreed on guidelines and principles to facilitate the generalizability of the atlas to individual cases. Conclusions: This expert panel successfully reached agreement on contouring guidelines for esophageal and GEJ IMRT and generated a reference CTV atlas. This atlas will serve as a reference for IMRT contours for clinical practice and prospective trial design. Subsequent patterns of failure analyses of clinical datasets using these guidelines may require modification in the future.

  2. Intensity-Modulated Radiation Therapy With Concurrent Chemotherapy as Preoperative Treatment for Localized Gastric Adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Chakravarty, Twisha; Crane, Christopher H. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Ajani, Jaffer A. [Department of Gastrointestinal Medical Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Mansfield, Paul F. [Department of Surgical Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Briere, Tina M.; Beddar, A. Sam [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Mok, Henry; Reed, Valerie K.; Krishnan, Sunil; Delclos, Marc E. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Das, Prajnan, E-mail: PrajDas@mdanderson.org [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2012-06-01

    Purpose: The goal of this study was to evaluate dosimetric parameters, acute toxicity, pathologic response, and local control in patients treated with preoperative intensity-modulated radiation therapy (IMRT) and concurrent chemotherapy for localized gastric adenocarcinoma. Methods: Between November 2007 and April 2010, 25 patients with localized gastric adenocarcinoma were treated with induction chemotherapy, followed by preoperative IMRT and concurrent chemotherapy and, finally, surgical resection. The median radiation therapy dose was 45 Gy. Concurrent chemotherapy was 5-fluorouracil and oxaliplatin in 18 patients, capecitabine in 3, and other regimens in 4. Subsequently, resection was performed with total gastrectomy in 13 patients, subtotal gastrectomy in 7, and other surgeries in 5. Results: Target coverage, expressed as the ratio of the minimum dose received by 99% of the planning target volume to the prescribed dose, was a median of 0.97 (range, 0.92-1.01). The median V{sub 30} (percentage of volume receiving at least 30 Gy) for the liver was 26%; the median V{sub 20} (percentage of volume receiving at least 20 Gy) for the right and left kidneys was 14% and 24%, respectively; and the median V{sub 40} (percentage of volume receiving at least 40 Gy) for the heart was 18%. Grade 3 acute toxicity developed in 14 patients (56%), including dehydration in 10, nausea in 8, and anorexia in 5. Grade 4 acute toxicity did not develop in any patient. There were no significant differences in the rates of acute toxicity, hospitalization, or feeding tube use in comparison to those in a group of 50 patients treated with preoperative three-dimensional conformal radiation therapy with concurrent chemotherapy. R0 resection was obtained in 20 patients (80%), and pathologic complete response occurred in 5 (20%). Conclusions: Preoperative IMRT for gastric adenocarcinoma was well tolerated, accomplished excellent target coverage and normal structure sparing, and led to appropriate

  3. Predictors of Dysgeusia in Patients With Oropharyngeal Cancer Treated With Chemotherapy and Intensity Modulated Radiation Therapy

    International Nuclear Information System (INIS)

    Sapir, Eli; Tao, Yebin; Feng, Felix; Samuels, Stuart; El Naqa, Issam; Murdoch-Kinch, Carol A.; Feng, Mary; Schipper, Matthew; Eisbruch, Avraham

    2016-01-01

    Objective(s): Dysgeusia is a significant factor reducing quality of life and worsening dysphagia in patients receiving chemoradiation therapy for head and neck cancer. The factors affecting dysgeusia severity are uncertain. We investigated the effects on patient-reported dysgeusia of doses to the oral cavity, salivary output (required to dissolve food particles), and patient-reported xerostomia. Methods and Materials: Seventy-three patients with stage III to IV oropharyngeal cancer (OPC) (N=73) receiving definitive intensity modulated radiation therapy concurrently with chemotherapy participated in a prospective, longitudinal study of quality of life (QOL), including assessment of patient-reported gustatory function by taste-related questions from the Head and Neck QOL instrument (HNQOL) and the University of Washington Head and Neck-related QOL instrument (UWQOL), before therapy and periodically after treatment. At these intervals, patients also completed a validated xerostomia-specific questionnaire (XQ) and underwent unstimulated and stimulated major salivary gland flow rate measurements. Results: At 1, 3, 6, and 12 months after treatment, dysgeusia improved over time: severe dysgeusia was reported by 50%, 40%, 22%, and 23% of patients, respectively. Significant associations were found between patient-reported severe dysgeusia and radiation dose to the oral cavity (P=.005) and tongue (P=.019); normal tissue complication probability for severe dysgeusia at 3 months showed mean oral cavity D 50 doses 53 Gy and 57 Gy in the HNQOL and WUQOL questionnaires, respectively, with curve slope (m) of 0.41. Measured salivary output was not statistically significantly correlated with severe taste dysfunction, whereas patient-reported XQ summary scores and xerostomia while eating scores were correlated with severe dysgeusia in the UWQOL tool (P=.04). Conclusions: Taste impairment is significantly correlated with mean radiation dose to the oral cavity. Patient

  4. Dosimetric predictors of hypothyroidism in oropharyngeal cancer patients treated with intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Chyan, Arthur; Chen, Josephine; Shugard, Erin; Lambert, Louise; Quivey, Jeanne M; Yom, Sue S

    2014-01-01

    Radiation to the neck has long been associated with an elevated risk of hypothyroidism development. The goal of the present work is to define dosimetric predictors of hypothyroidism in oropharyngeal cancer (OPC) patients treated with intensity-modulated radiation therapy. Data for 123 patients, with a median follow up of 4.6 years, were retrospectively analyzed. Patients with elevated thyroid-stimulating hormone levels or with a clinical diagnosis were categorized as hypothyroid. Patient demographic parameters, thyroid volume, mean thyroid dose, the percent of thyroid volume receiving minimum specified dose levels (VxxGy), and the absolute thyroid volume spared from specified dose levels (VSxxGy) were analyzed. Normal-tissue complication probability (NTCP) was also calculated using several recently published models. Thyroid volume and many radiation dosimetric parameters were statistically different in the hypothyroid group. For the patients with initial thyroid volumes of 8 cc or greater, several dosimetric parameters were found to define subgroups at statistically significant lower risk of developing hypothyroidism. Patients with VS45 Gy of at least 3 cc, VS50 Gy at least 5 cc, VS50 Gy at least 6 cc, V50 Gy below 45%, V50 Gy below 55%, or mean thyroid dose below 49 Gy had a 28-38% estimated risk of hypothyroidism at 3 years compared to a 55% risk for the entire study group. Patients with a NTCP of less than 0.75 or 0.8, calculated using recently published models, were also observed to have a lower risk of developing hypothyroidism. Based on long-term follow up data for OPC patients treated with IMRT, we recommend plan optimization objectives to reduce the volume of thyroid receiving over 45 Gy to significantly decrease the risk of developing hypothyroidism. The online version of this article (doi:10.1186/s13014-014-0269-4) contains supplementary material, which is available to authorized users

  5. Intensity modulated radiation therapy with field rotation--a time-varying fractionation study.

    Science.gov (United States)

    Dink, Delal; Langer, Mark P; Rardin, Ronald L; Pekny, Joseph F; Reklaitis, Gintaras V; Saka, Behlul

    2012-06-01

    This paper proposes a novel mathematical approach to the beam selection problem in intensity modulated radiation therapy (IMRT) planning. The approach allows more beams to be used over the course of therapy while limiting the number of beams required in any one session. In the proposed field rotation method, several sets of beams are interchanged throughout the treatment to allow a wider selection of beam angles than would be possible with fixed beam orientations. The choice of beamlet intensities and the number of identical fractions for each set are determined by a mixed integer linear program that controls jointly for the distribution per fraction and the cumulative dose distribution delivered to targets and critical structures. Trials showed the method allowed substantial increases in the dose objective and/or sparing of normal tissues while maintaining cumulative and fraction size limits. Trials for a head and neck site showed gains of 25%-35% in the objective (average tumor dose) and for a thoracic site gains were 7%-13%, depending on how strict the fraction size limits were set. The objective did not rise for a prostate site significantly, but the tolerance limits on normal tissues could be strengthened with the use of multiple beam sets.

  6. Dosimetric comparison of tools for intensity modulated radiation therapy with gamma analysis: a phantom study

    Directory of Open Access Journals (Sweden)

    Akbas Ugur

    2015-01-01

    Full Text Available Dosimetry of the Intensity Modulated Radiation Therapy (IMRT is very important because of the complex dose distributions. Diode arrays are the most common and practical measurement tools for clinical usage for IMRT. Phantom selection is critical for QA process. IMRT treatment plans are recalculated for the phantom irradiation in QA. Phantoms are made in different geometrical shapes to measure the doses of different types of irradiation techniques. Comparison of measured and calculated dose distributions for IMRT can be made by using gamma analysis. In this study, 10 head-and-neck IMRT QA plans were created with Varian Eclipse 8.9 treatment planning system. Water equivalent RW3-slab phantoms, Octavius-2 phantom and PTW Seven29 2D-array were used for QA measurements. Gantry, collimator and couch positions set to 00 and QA plans were delivered to RW3 and Octavius phantoms. Then the positions set to original angles and QA plans irradiated again. Measured and calculated fluence maps were evaluated with gamma analysis for different DD and DTA criteria. The effect of different set-up conditions for RW3 and Octavius phantoms in QA plan delivery evaluated by gamma analysis. Results of gamma analysis show that using RW3-slab phantoms with setting parameters to 00 is more appropriate for IMRT QA.

  7. Organisational standards for the delivery of intensity-modulated radiation therapy in Ontario.

    Science.gov (United States)

    Whitton, A; Warde, P; Sharpe, M; Oliver, T K; Bak, K; Leszczynski, K; Etheridge, S; Fleming, K; Gutierrez, E; Favell, L; Green, E

    2009-04-01

    By minimising the effect of irradiation on surrounding tissue, intensity-modulated radiation therapy (IMRT) can deliver higher, more effective doses to the targeted tumour site, minimising treatment-related morbidity and possibly improving cancer control and cure. A multidisciplinary IMRT Expert Panel was convened to develop the organisational standards for the delivery of IMRT. The systematic literature search used MEDLINE, EMBASE, the Cochrane Database, the National Guidelines Clearing House and the Health Technology Assessment Database. An environmental scan of unpublished literature used the Google search engine to review the websites of key organisations, cancer agencies/centres and vendor sites in Canada, the USA, Australia and Europe. In total, 22 relevant guidance documents were identified; 12 from the published literature and 10 from the environmental scan. Professional and organisational standards for the provision of IMRT were developed through the analysis of this evidence and the consensus opinion of the IMRT Expert Panel. The resulting standards address the following domains: planning of new IMRT programmes, practice setting requirements, tools, devices and equipment requirements; professional training requirements; role of personnel; and requirements for quality assurance and safety. Here the IMRT Expert Panel offers organisational and professional standards for the delivery of IMRT, with the intent of promoting innovation, improving access and enhancing patient care.

  8. Direct-aperture optimization applied to selection of beam orientations in intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Bedford, J L; Webb, S

    2007-01-01

    Direct-aperture optimization (DAO) was applied to iterative beam-orientation selection in intensity-modulated radiation therapy (IMRT), so as to ensure a realistic segmental treatment plan at each iteration. Nested optimization engines dealt separately with gantry angles, couch angles, collimator angles, segment shapes, segment weights and wedge angles. Each optimization engine performed a random search with successively narrowing step sizes. For optimization of segment shapes, the filtered backprojection (FBP) method was first used to determine desired fluence, the fluence map was segmented, and then constrained direct-aperture optimization was used thereafter. Segment shapes were fully optimized when a beam angle was perturbed, and minimally re-optimized otherwise. The algorithm was compared with a previously reported method using FBP alone at each orientation iteration. An example case consisting of a cylindrical phantom with a hemi-annular planning target volume (PTV) showed that for three-field plans, the method performed better than when using FBP alone, but for five or more fields, neither method provided much benefit over equally spaced beams. For a prostate case, improved bladder sparing was achieved through the use of the new algorithm. A plan for partial scalp treatment showed slightly improved PTV coverage and lower irradiated volume of brain with the new method compared to FBP alone. It is concluded that, although the method is computationally intensive and not suitable for searching large unconstrained regions of beam space, it can be used effectively in conjunction with prior class solutions to provide individually optimized IMRT treatment plans

  9. A nested partitions framework for beam angle optimization in intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    D'Souza, Warren D; Nazareth, Daryl P; Zhang, Hao H; Shi Leyuan; Meyer, Robert R

    2008-01-01

    Coupling beam angle optimization with dose optimization in intensity-modulated radiation therapy (IMRT) increases the size and complexity of an already large-scale combinatorial optimization problem. We have developed a novel algorithm, nested partitions (NP), that is capable of finding suitable beam angle sets by guiding the dose optimization process. NP is a metaheuristic that is flexible enough to guide the search of a heuristic or deterministic dose optimization algorithm. The NP method adaptively samples from the entire feasible region, or search space, and coordinates the sampling effort with a systematic partitioning of the feasible region at successive iterations, concentrating the search in promising subsets. We used a 'warm-start' approach by initiating NP with beam angle samples derived from an integer programming (IP) model. In this study, we describe our implementation of the NP framework with a commercial optimization algorithm. We compared the NP framework with equi-spaced beam angle selection, the IP method, greedy heuristic and random sampling heuristic methods. The results of the NP approach were evaluated using two clinical cases (head and neck and whole pelvis) involving the primary tumor and nodal volumes. Our results show that NP produces better quality solutions than the alternative considered methods

  10. A nested partitions framework for beam angle optimization in intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    D' Souza, Warren D; Nazareth, Daryl P [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD (United States); Zhang, Hao H; Shi Leyuan [Department of Industrial and Systems Engineering, University of Wisconsin, Madison, WI (United States); Meyer, Robert R [Computer Sciences Department, University of Wisconsin, Madison, WI (United States)], E-mail: dsouzaw@ohsu.edu

    2008-06-21

    Coupling beam angle optimization with dose optimization in intensity-modulated radiation therapy (IMRT) increases the size and complexity of an already large-scale combinatorial optimization problem. We have developed a novel algorithm, nested partitions (NP), that is capable of finding suitable beam angle sets by guiding the dose optimization process. NP is a metaheuristic that is flexible enough to guide the search of a heuristic or deterministic dose optimization algorithm. The NP method adaptively samples from the entire feasible region, or search space, and coordinates the sampling effort with a systematic partitioning of the feasible region at successive iterations, concentrating the search in promising subsets. We used a 'warm-start' approach by initiating NP with beam angle samples derived from an integer programming (IP) model. In this study, we describe our implementation of the NP framework with a commercial optimization algorithm. We compared the NP framework with equi-spaced beam angle selection, the IP method, greedy heuristic and random sampling heuristic methods. The results of the NP approach were evaluated using two clinical cases (head and neck and whole pelvis) involving the primary tumor and nodal volumes. Our results show that NP produces better quality solutions than the alternative considered methods.

  11. Automation of the solution type of intensity modulated radiation therapy with direct planning neoplastic breast lesions

    International Nuclear Information System (INIS)

    Fuente Rosales, Liset De La; Larrinaga Cortina, Eduardo Francisco

    2009-01-01

    Breast cancer ranks first among the lesions malignancies involving the Cuban women and the second in mortality only surpassed by lung injury. The breast-conserving surgery is becoming less appeal, with an increase in the choice of radiotherapy to the breast operated, and the surgical bed. Intensity Modulated Radiation Therapy, IMRT has demonstrated better results in the dose distribution for irradiation dimensional treatment breast shaping, 3DCRT. We developed a MATLAB application to obtain the solution type to direct planning IMRT for breast neoplasm. The technique was implemented in the Planning System Treatment Plus Theraplan v3.8 and Precise1 ELEKTA linear accelerator. Static segments are constructed for each portal of incidence and Excel files are exported as the positions of the blades. The technique was validated with a patient, which he performed a radiographic study of computerized axial tomography planning purposes. The standard solution built is consistent with those reported internationally and consists of a segment type and at least two segments of type B. The assignment of the relative weights of the segments is done manually by trial and error procedure, with the general rule of 90% by weight assigned to segment A and the remaining 10% divided equally between B-type segments IMRT breast obtained in a dose 17% homogeneity better than 3DCRT and reduced the average dose in the lung ipsilateral 15%. (author)

  12. Meningioma Causing Visual Impairment: Outcomes and Toxicity After Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Maclean, Jillian, E-mail: jillian.maclean@uclh.nhs.uk [Radiotherapy Department, University College London Hospital, London (United Kingdom); Fersht, Naomi [Radiotherapy Department, University College London Hospital, London (United Kingdom); Bremner, Fion [Neuro-Ophthalmology Department, National Hospital for Neurology and Neurosurgery, London (United Kingdom); Stacey, Chris; Sivabalasingham, Suganya [Radiotherapy Department, University College London Hospital, London (United Kingdom); Short, Susan [Radiotherapy Department, University College London Hospital, London (United Kingdom); Leeds Institute of Molecular Medicine, St James University Hospital, Leeds (United Kingdom)

    2013-03-15

    Purpose: To evaluate ophthalmologic outcomes and toxicity of intensity modulated radiation therapy (IMRT) in patients with meningiomas causing visual deficits. Methods and Materials: A prospective observational study with formal ophthalmologic and clinical assessment of 30 consecutive cases of meningioma affecting vision treated with IMRT from 2007 to 2011. Prescriptions were 50.4 Gy to mean target dose in 28 daily fractions. The median follow-up time was 28 months. Twenty-six meningiomas affected the anterior visual pathway (including 3 optic nerve sheath meningiomas); 4 were posterior to the chiasm. Results: Vision improved objectively in 12 patients (40%). Improvements were in visual field (5/16 patients), color vision (4/9 patients), acuity (1/15 patients), extraocular movements (3/11 patients), ptosis (1/5 patients), and proptosis (2/6 patients). No predictors of clinical response were found. Two patients had minor reductions in tumor dimensions on magnetic resonance imaging, 1 patient had radiological progression, and the other patients were stable. One patient experienced grade 2 keratitis, 1 patient had a minor visual field loss, and 5 patients had grade 1 dry eye. Conclusion: IMRT is an effective method for treating meningiomas causing ophthalmologic deficits, and toxicity is minimal. Thorough ophthalmologic assessment is important because clinical responses often occur in the absence of radiological change.

  13. A novel radiation therapy technique for malignant pleural mesothelioma combining electrons with intensity-modulated photons

    International Nuclear Information System (INIS)

    Chan, Maria F.; Chui, Chen S.; Song Yulin; Burman, Chandra; Yorke, Ellen; Della-Biancia, Cesar; Rosenzweig, Kenneth E.; Schupak, Karen

    2006-01-01

    Background and purpose: To investigate the feasibility and potential benefits of combining electron and photon intensity modulated radiotherapy (IMRT) for patients with malignant pleural mesothelioma (MPM). Patients and methods: The planning CT images of 11 MPM patients, six after extrapleural pneumonectomy (EPP) and five after pleurectomy/decortication (P/D), were used for this study. These cases were planned with photon IMRT alone and photon IMRT combined with electrons (IMRT+e). The latter approach incorporated the electron dose into the inverse planning optimization. The resulting doses to the planning target volume (PTV) and relevant critical structures were compared. Results: For all patients, the PTV was well covered and doses to critical structures were clinically acceptable for all patients with both techniques. However, IMRT+e exhibited a distinct advantage in reducing the doses to the liver, ipsilateral kidney, contralateral kidney, and heart (P=0.002, 0.003, 0.025, and 0.001, respectively). Conclusions: This study showed that IMRT or IMRT+e is a viable treatment modality for MPM patients. Both plans can provide excellent target coverage and normal tissue sparing, but with the addition of electron beams, the critical structures can be further spared. Additional refining of the electron contribution is expected to further reduce radiation-induced morbidity

  14. An Ensemble Approach to Knowledge-Based Intensity-Modulated Radiation Therapy Planning

    Directory of Open Access Journals (Sweden)

    Jiahan Zhang

    2018-03-01

    Full Text Available Knowledge-based planning (KBP utilizes experienced planners’ knowledge embedded in prior plans to estimate optimal achievable dose volume histogram (DVH of new cases. In the regression-based KBP framework, previously planned patients’ anatomical features and DVHs are extracted, and prior knowledge is summarized as the regression coefficients that transform features to organ-at-risk DVH predictions. In our study, we find that in different settings, different regression methods work better. To improve the robustness of KBP models, we propose an ensemble method that combines the strengths of various linear regression models, including stepwise, lasso, elastic net, and ridge regression. In the ensemble approach, we first obtain individual model prediction metadata using in-training-set leave-one-out cross validation. A constrained optimization is subsequently performed to decide individual model weights. The metadata is also used to filter out impactful training set outliers. We evaluate our method on a fresh set of retrospectively retrieved anonymized prostate intensity-modulated radiation therapy (IMRT cases and head and neck IMRT cases. The proposed approach is more robust against small training set size, wrongly labeled cases, and dosimetric inferior plans, compared with other individual models. In summary, we believe the improved robustness makes the proposed method more suitable for clinical settings than individual models.

  15. SU-F-T-209: Multicriteria Optimization Algorithm for Intensity Modulated Radiation Therapy Using Pencil Proton Beam Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Beltran, C; Kamal, H [Mayo Clinic, Rochester, MN (United States)

    2016-06-15

    Purpose: To provide a multicriteria optimization algorithm for intensity modulated radiation therapy using pencil proton beam scanning. Methods: Intensity modulated radiation therapy using pencil proton beam scanning requires efficient optimization algorithms to overcome the uncertainties in the Bragg peaks locations. This work is focused on optimization algorithms that are based on Monte Carlo simulation of the treatment planning and use the weights and the dose volume histogram (DVH) control points to steer toward desired plans. The proton beam treatment planning process based on single objective optimization (representing a weighted sum of multiple objectives) usually leads to time-consuming iterations involving treatment planning team members. We proved a time efficient multicriteria optimization algorithm that is developed to run on NVIDIA GPU (Graphical Processing Units) cluster. The multicriteria optimization algorithm running time benefits from up-sampling of the CT voxel size of the calculations without loss of fidelity. Results: We will present preliminary results of Multicriteria optimization for intensity modulated proton therapy based on DVH control points. The results will show optimization results of a phantom case and a brain tumor case. Conclusion: The multicriteria optimization of the intensity modulated radiation therapy using pencil proton beam scanning provides a novel tool for treatment planning. Work support by a grant from Varian Inc.

  16. SU-F-T-209: Multicriteria Optimization Algorithm for Intensity Modulated Radiation Therapy Using Pencil Proton Beam Scanning

    International Nuclear Information System (INIS)

    Beltran, C; Kamal, H

    2016-01-01

    Purpose: To provide a multicriteria optimization algorithm for intensity modulated radiation therapy using pencil proton beam scanning. Methods: Intensity modulated radiation therapy using pencil proton beam scanning requires efficient optimization algorithms to overcome the uncertainties in the Bragg peaks locations. This work is focused on optimization algorithms that are based on Monte Carlo simulation of the treatment planning and use the weights and the dose volume histogram (DVH) control points to steer toward desired plans. The proton beam treatment planning process based on single objective optimization (representing a weighted sum of multiple objectives) usually leads to time-consuming iterations involving treatment planning team members. We proved a time efficient multicriteria optimization algorithm that is developed to run on NVIDIA GPU (Graphical Processing Units) cluster. The multicriteria optimization algorithm running time benefits from up-sampling of the CT voxel size of the calculations without loss of fidelity. Results: We will present preliminary results of Multicriteria optimization for intensity modulated proton therapy based on DVH control points. The results will show optimization results of a phantom case and a brain tumor case. Conclusion: The multicriteria optimization of the intensity modulated radiation therapy using pencil proton beam scanning provides a novel tool for treatment planning. Work support by a grant from Varian Inc.

  17. Bile Acid Malabsorption After Pelvic and Prostate Intensity Modulated Radiation Therapy: An Uncommon but Treatable Condition

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Victoria [Academic Urology Unit, Institute of Cancer Research and The Royal Marsden Hospital, London and Sutton (United Kingdom); Benton, Barbara [Gastroenterology Unit, Institute of Cancer Research and The Royal Marsden Hospital, London and Sutton (United Kingdom); Sohaib, Aslam [Department of Radiology, Institute of Cancer Research and The Royal Marsden Hospital, London and Sutton (United Kingdom); Dearnaley, David [Academic Urology Unit, Institute of Cancer Research and The Royal Marsden Hospital, London and Sutton (United Kingdom); Andreyev, H. Jervoise N., E-mail: j@andreyev.demon.co.uk [Gastroenterology Unit, Institute of Cancer Research and The Royal Marsden Hospital, London and Sutton (United Kingdom)

    2012-12-01

    Purpose: Intensity modulated radiation therapy (IMRT) is a significant therapeutic advance in prostate cancer, allowing increased tumor dose delivery and increased sparing of normal tissues. IMRT planning uses strict dose constraints to nearby organs to limit toxicity. Bile acid malabsorption (BAM) is a treatable disorder of the terminal ileum (TI) that presents with symptoms similar to radiation therapy toxicity. It has not been described in patients receiving RT for prostate cancer in the contemporary era. We describe new-onset BAM in men after IMRT for prostate cancer. Methods and Materials: Diagnosis of new-onset BAM was established after typical symptoms developed, selenium-75 homocholic acid taurine (SeHCAT) scanning showed 7-day retention of <15%, and patients' symptoms unequivocally responded to a bile acid sequestrant. The TI was identified on the original radiation therapy plan, and the radiation dose delivered was calculated and compared with accepted dose-volume constraints. Results: Five of 423 men treated in a prospective series of high-dose prostate and pelvic IMRT were identified with new onset BAM (median age, 65 years old). All reported having normal bowel habits before RT. The volume of TI ranged from 26-141 cc. The radiation dose received by the TI varied between 11.4 Gy and 62.1 Gy (uncorrected). Three of 5 patients had TI treated in excess of 45 Gy (equivalent dose calculated in 2-Gy fractions, using an {alpha}/{beta} ratio of 3) with volumes ranging from 1.6 cc-49.0 cc. One patient had mild BAM (SeHCAT retention, 10%-15%), 2 had moderate BAM (SeHCAT retention, 5%-10%), and 2 had severe BAM (SeHCAT retention, <5%). The 3 patients whose TI received {>=}45 Gy developed moderate to severe BAM, whereas those whose TI received <45 Gy had only mild to moderate BAM. Conclusions: Radiation delivered to the TI during IMRT may cause BAM. Identification of the TI from unenhanced RT planning computed tomography scans is difficult and may impede

  18. Ototoxicity After Intensity-Modulated Radiation Therapy and Cisplatin-Based Chemotherapy in Children With Medulloblastoma

    International Nuclear Information System (INIS)

    Paulino, Arnold C.; Lobo, Mark; Teh, Bin S.; Okcu, M. Fatih; South, Michael; Butler, E. Brian; Su, Jack; Chintagumpala, Murali

    2010-01-01

    Purpose: To report the incidence of Pediatric Oncology Group (POG) Grade 3 or 4 ototoxicity in a cohort of patients treated with craniospinal irradiation (CSI) followed by posterior fossa (PF) and/or tumor bed (TB) boost using intensity-modulated radiation therapy (IMRT). Methods and Materials: From 1998 to 2006, 44 patients with medulloblastoma were treated with CSI followed by IMRT to the PF and/or TB and cisplatin-based chemotherapy. Patients with standard-risk disease were treated with 18 to 23.4 Gy CSI followed by either a (1) PF boost to 36 Gy and TB boost to 54 to 55.8 Gy or (2) TB boost to 55.8 Gy. Patients with high-risk disease received 36 to 39.6 Gy CSI followed by a (1) PF boost to 54 to 55.8 Gy, (2) PF boost to 45 Gy and TB boost to 55.8 Gy, or (3) TB boost to 55.8 Gy. Median audiogram follow-up was 41 months (range, 11-92.4 months). Results: POG Grade Ototoxicity 0, 1, 2, 3. and 4 was found in 29, 32, 11, 13. and 3 ears. respectively, with POG Grade 3 or 4 accounting for 18.2% of cases. There was a statistically significant difference in mean radiation dose (D mean ) cochlea according to degree of ototoxicity, with D mean cochlea increasing with severity of hearing loss (p = 0.027). Conclusions: Severe ototoxicity was seen in 18.2% of ears in children treated with IMRT boost and cisplatin-based chemotherapy. Increasing dose to the cochlea was associated with increasing severity of hearing loss.

  19. Adoption of Intensity Modulated Radiation Therapy For Early-Stage Breast Cancer From 2004 Through 2011

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Elyn H. [Yale School of Medicine, New Haven, Connecticut (United States); Mougalian, Sarah S. [Yale School of Medicine, New Haven, Connecticut (United States); Yale Cancer Center, New Haven, Connecticut (United States); Cancer Outcomes, Public Policy, and Effectiveness Research Center at Yale, New Haven, Connecticut (United States); Soulos, Pamela R. [Yale School of Medicine, New Haven, Connecticut (United States); Cancer Outcomes, Public Policy, and Effectiveness Research Center at Yale, New Haven, Connecticut (United States); Department of Internal Medicine, Yale School of Medicine, New Haven, Connecticut (United States); Smith, Benjamin D. [Department of Radiation Oncology, MD Anderson Cancer Center, Houston, Texas (United States); Haffty, Bruce G. [Rutgers Cancer Institute of New Jersey, New Brunswick, New Jersey (United States); Gross, Cary P. [Yale School of Medicine, New Haven, Connecticut (United States); Cancer Outcomes, Public Policy, and Effectiveness Research Center at Yale, New Haven, Connecticut (United States); Department of Internal Medicine, Yale School of Medicine, New Haven, Connecticut (United States); Yu, James B., E-mail: james.b.yu@yale.edu [Yale School of Medicine, New Haven, Connecticut (United States); Cancer Outcomes, Public Policy, and Effectiveness Research Center at Yale, New Haven, Connecticut (United States); Department of Therapeutic Radiology, Yale School of Medicine, New Haven, Connecticut (United States)

    2015-02-01

    Purpose: Intensity modulated radiation therapy (IMRT) is a newer method of radiation therapy (RT) that has been increasingly adopted as an adjuvant treatment after breast-conserving surgery (BCS). IMRT may result in improved cosmesis compared to standard RT, although at greater expense. To investigate the adoption of IMRT, we examined trends and factors associated with IMRT in women under the age of 65 with early stage breast cancer. Methods and Materials: We performed a retrospective study of early stage breast cancer patients treated with BCS followed by whole-breast irradiation (WBI) who were ≤65 years old in the National Cancer Data Base from 2004 to 2011. We used logistic regression to identify factors associated with receipt of IMRT (vs standard RT). Results: We identified 11,089 women with early breast cancer (9.6%) who were treated with IMRT and 104,448 (90.4%) who were treated with standard RT, after BCS. The proportion of WBI patients receiving IMRT increased yearly from 2004 to 2009, with 5.3% of WBI patients receiving IMRT in 2004 and 11.6% receiving IMRT in 2009. Further use of IMRT declined afterward, with the proportion remaining steady at 11.0% and 10.7% in 2010 and 2011, respectively. Patients treated in nonacademic community centers were more likely to receive IMRT (odds ratio [OR], 1.36; 95% confidence interval [CI], 1.30-1.43 for nonacademic vs academic center). Compared to privately insured patients, the uninsured patients (OR, 0.81; 95% CI, 0.70-0.95) and those with Medicaid insurance (OR, 0.87; 95% CI, 0.79-0.95) were less likely to receive IMRT. Conclusions: The use of IMRT rose from 2004 to 2009 and then stabilized. Important nonclinical factors associated with IMRT use included facility type and insurance status.

  20. Intensity-Modulated Radiation Therapy Significantly Improves Acute Gastrointestinal Toxicity in Pancreatic and Ampullary Cancers

    International Nuclear Information System (INIS)

    Yovino, Susannah; Poppe, Matthew; Jabbour, Salma; David, Vera; Garofalo, Michael; Pandya, Naimesh; Alexander, Richard; Hanna, Nader; Regine, William F.

    2011-01-01

    Purpose: Among patients with upper abdominal malignancies, intensity-modulated radiation therapy (IMRT) can improve dose distributions to critical dose-limiting structures near the target. Whether these improved dose distributions are associated with decreased toxicity when compared with conventional three-dimensional treatment remains a subject of investigation. Methods and Materials: 46 patients with pancreatic/ampullary cancer were treated with concurrent chemoradiation (CRT) using inverse-planned IMRT. All patients received CRT based on 5-fluorouracil in a schema similar to Radiation Therapy Oncology Group (RTOG) 97-04. Rates of acute gastrointestinal (GI) toxicity for this series of IMRT-treated patients were compared with those from RTOG 97-04, where all patients were treated with three-dimensional conformal techniques. Chi-square analysis was used to determine if there was a statistically different incidence in acute GI toxicity between these two groups of patients. Results: The overall incidence of Grade 3-4 acute GI toxicity was low in patients receiving IMRT-based CRT. When compared with patients who had three-dimensional treatment planning (RTOG 97-04), IMRT significantly reduced the incidence of Grade 3-4 nausea and vomiting (0% vs. 11%, p = 0.024) and diarrhea (3% vs. 18%, p = 0.017). There was no significant difference in the incidence of Grade 3-4 weight loss between the two groups of patients. Conclusions: IMRT is associated with a statistically significant decrease in acute upper and lower GI toxicity among patients treated with CRT for pancreatic/ampullary cancers. Future clinical trials plan to incorporate the use of IMRT, given that it remains a subject of active investigation.

  1. Calibration of CT density values in dosimetry verification of intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Zhuang Mingzan; Wu Renhua; Qiu Qingchun; Peng Xun; Lu Jiayang; Chen Zhijian

    2011-01-01

    Objective: Based on intensity modulated radiation therapy (IMRT) phantom, the impact of CT-to-density conversion curve on dosimetry verification of IMRT is investigated and calibrated. Methods: The electron density phantom was used to establish the CT-to-density conversion curve in radiation treatment planning system. IMRT plans of 12 nasopharynx carcinoma patients were chosen, copied to IMRT phantom and computed for the dose distribution. For each plan a measured point was put at the place where the dose was well-distributed and its dose value was measured using the ionization chamber. The physical density of IMRT phantom and its CT value were input into the planning system, to make a calibration for the CT-to-density conversion curve. The dose distribution was recomputed for each IMRT plan. Other parameters were kept the same in the plans and the differences between the computed dose values before and after correction were compared with the measured values. Results: In 12 nasopharynx carcinoma IMRT plans, the average error of computed dose values was 1.96%±0.87% before correction and 0.63%±0.74% after correction, compared with measured values. The error between measured values and computed values after correction was less than ±2% whereas the maximum error of computed values before correction was 3.24%. Conclusions: The computed dose values are closer to the measured values when using the calibrated CT-to-density conversion curve. The CT density values of IMRT phantom should be verified before usage, so as to increase the accuracy of IMRT dosimetry verification. (authors)

  2. Intensity modulated radiation-therapy for preoperative posterior abdominal wall irradiation of retroperitoneal liposarcomas

    International Nuclear Information System (INIS)

    Bossi, Alberto; De Wever, Ivo; Van Limbergen, Erik; Vanstraelen, Bianca

    2007-01-01

    Purpose: Preoperative external-beam radiation therapy (preop RT) in the management of Retroperitoneal Liposarcomas (RPLS) typically involves the delivery of radiation to the entire tumor mass: yet this may not be necessary. The purpose of this study is to evaluate a new strategy of preop RT for RPLS in which the target volume is limited to the contact area between the tumoral mass and the posterior abdominal wall. Methods and Materials: Between June 2000 and Jan 2005, 18 patients with the diagnosis of RPLS have been treated following a pilot protocol of pre-op RT, 50 Gy in 25 fractions of 2 Gy/day. The Clinical Target Volume (CTV) has been limited to the posterior abdominal wall, region at higher risk for local relapse. A Three-Dimensional conformal (3D-CRT) and an Intensity Modulated (IMRT) plan were generated and compared; toxicity was reported following the National Cancer Institute (NCI) Common Terminology Criteria for Adverse Events v3.0. Results: All patients completed the planned treatment and the acute toxicity was tolerable: 2 patients experienced Grade 3 and 1 Grade 2 anorexia while 2 patients developed Grade 2 nausea. IMRT allows a better sparing of the ipsilateral and the contralateral kidney. All tumors were successfully resected without major complications. At a median follow-up of 27 months 2 patients developed a local relapse and 1 lung metastasis. Conclusions: Our strategy of preop RT is feasible and well tolerated: the rate of resectability is not compromised by limiting the preop CTV to the posterior abdominal wall and a better critical-structures sparing is obtained with IMRT

  3. Adoption of Intensity Modulated Radiation Therapy For Early-Stage Breast Cancer From 2004 Through 2011

    International Nuclear Information System (INIS)

    Wang, Elyn H.; Mougalian, Sarah S.; Soulos, Pamela R.; Smith, Benjamin D.; Haffty, Bruce G.; Gross, Cary P.; Yu, James B.

    2015-01-01

    Purpose: Intensity modulated radiation therapy (IMRT) is a newer method of radiation therapy (RT) that has been increasingly adopted as an adjuvant treatment after breast-conserving surgery (BCS). IMRT may result in improved cosmesis compared to standard RT, although at greater expense. To investigate the adoption of IMRT, we examined trends and factors associated with IMRT in women under the age of 65 with early stage breast cancer. Methods and Materials: We performed a retrospective study of early stage breast cancer patients treated with BCS followed by whole-breast irradiation (WBI) who were ≤65 years old in the National Cancer Data Base from 2004 to 2011. We used logistic regression to identify factors associated with receipt of IMRT (vs standard RT). Results: We identified 11,089 women with early breast cancer (9.6%) who were treated with IMRT and 104,448 (90.4%) who were treated with standard RT, after BCS. The proportion of WBI patients receiving IMRT increased yearly from 2004 to 2009, with 5.3% of WBI patients receiving IMRT in 2004 and 11.6% receiving IMRT in 2009. Further use of IMRT declined afterward, with the proportion remaining steady at 11.0% and 10.7% in 2010 and 2011, respectively. Patients treated in nonacademic community centers were more likely to receive IMRT (odds ratio [OR], 1.36; 95% confidence interval [CI], 1.30-1.43 for nonacademic vs academic center). Compared to privately insured patients, the uninsured patients (OR, 0.81; 95% CI, 0.70-0.95) and those with Medicaid insurance (OR, 0.87; 95% CI, 0.79-0.95) were less likely to receive IMRT. Conclusions: The use of IMRT rose from 2004 to 2009 and then stabilized. Important nonclinical factors associated with IMRT use included facility type and insurance status

  4. Fast voxel and polygon ray-tracing algorithms in intensity modulated radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Fox, Christopher; Romeijn, H. Edwin; Dempsey, James F.

    2006-01-01

    We present work on combining three algorithms to improve ray-tracing efficiency in radiation therapy dose computation. The three algorithms include: An improved point-in-polygon algorithm, incremental voxel ray tracing algorithm, and stereographic projection of beamlets for voxel truncation. The point-in-polygon and incremental voxel ray-tracing algorithms have been used in computer graphics and nuclear medicine applications while the stereographic projection algorithm was developed by our group. These algorithms demonstrate significant improvements over the current standard algorithms in peer reviewed literature, i.e., the polygon and voxel ray-tracing algorithms of Siddon for voxel classification (point-in-polygon testing) and dose computation, respectively, and radius testing for voxel truncation. The presented polygon ray-tracing technique was tested on 10 intensity modulated radiation therapy (IMRT) treatment planning cases that required the classification of between 0.58 and 2.0 million voxels on a 2.5 mm isotropic dose grid into 1-4 targets and 5-14 structures represented as extruded polygons (a.k.a. Siddon prisms). Incremental voxel ray tracing and voxel truncation employing virtual stereographic projection was tested on the same IMRT treatment planning cases where voxel dose was required for 230-2400 beamlets using a finite-size pencil-beam algorithm. Between a 100 and 360 fold cpu time improvement over Siddon's method was observed for the polygon ray-tracing algorithm to perform classification of voxels for target and structure membership. Between a 2.6 and 3.1 fold reduction in cpu time over current algorithms was found for the implementation of incremental ray tracing. Additionally, voxel truncation via stereographic projection was observed to be 11-25 times faster than the radial-testing beamlet extent approach and was further improved 1.7-2.0 fold through point-classification using the method of translation over the cross product technique

  5. Vaginal Motion and Bladder and Rectal Volumes During Pelvic Intensity-Modulated Radiation Therapy After Hysterectomy

    Energy Technology Data Exchange (ETDEWEB)

    Jhingran, Anuja, E-mail: ajhingra@mdanderson.org [Department of Radiation Oncology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Salehpour, Mohammad [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Sam, Marianne; Levy, Larry; Eifel, Patricia J. [Department of Radiation Oncology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States)

    2012-01-01

    Purpose: To evaluate variations in bladder and rectal volume and the position of the vaginal vault during a 5-week course of pelvic intensity-modulated radiation therapy (IMRT) after hysterectomy. Methods and Materials: Twenty-four patients were instructed how to fill their bladders before simulation and treatment. These patients underwent computed tomography simulations with full and empty bladders and then underwent rescanning twice weekly during IMRT; patients were asked to have full bladder for treatment. Bladder and rectal volumes and the positions of vaginal fiducial markers were determined, and changes in volume and position were calculated. Results: The mean full and empty bladder volumes at simulation were 480 cc (range, 122-1,052) and 155 cc (range, 49-371), respectively. Bladder volumes varied widely during IMRT: the median difference between the maximum and minimum volumes was 247 cc (range, 96-585). Variations in rectal volume during IMRT were less pronounced. For the 16 patients with vaginal fiducial markers in place throughout IMRT, the median maximum movement of the markers during IMRT was 0.59 cm in the right-left direction (range, 0-0.9), 1.46 cm in the anterior-posterior direction (range, 0.8-2.79), and 1.2 cm in the superior-inferior direction (range, 0.6-2.1). Large variations in rectal or bladder volume frequently correlated with significant displacement of the vaginal apex. Conclusion: Although treatment with a full bladder is usually preferred because of greater sparing of small bowel, our data demonstrate that even with detailed instruction, patients are unable to maintain consistent bladder filling. Variations in organ position during IMRT can result in marked changes in the position of the target volume and the volume of small bowel exposed to high doses of radiation.

  6. Reirradiation of Head and Neck Cancers With Intensity Modulated Radiation Therapy: Outcomes and Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Takiar, Vinita [Department of Radiation Oncology, University of Cincinnati, Cincinnati, Ohio (United States); Garden, Adam S.; Ma, Dominic; Morrison, William H.; Edson, Mark [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Zafereo, Mark E. [Department of Surgical Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Gunn, Gary B.; Fuller, Clifton D.; Beadle, Beth; Frank, Steven J. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); William, William N.; Kies, Merrill [Department of Medical Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); El-Naggar, Adel K. [Department of Pathology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Weber, Randal [Department of Surgical Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Rosenthal, David I. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Phan, Jack, E-mail: jphan@mdanderson.org [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2016-07-15

    Purpose: To review our 15-year institutional experience using intensity modulated radiation therapy (IMRT) to reirradiate patients with head and neck squamous cell carcinomas (HNSCC) and identify predictors of outcomes and toxicity. Methods and Materials: We retrospectively reviewed the records of 227 patients who received head and neck reirradiation using IMRT from 1999 to 2014. Patients treated with noncurative intent were excluded. Radiation-related acute and late toxicities were recorded. Prognostic variables included performance status, disease site, disease-free interval, chemotherapy, and RT dose and volume. Correlative analyses were performed separately for surgery and nonsurgery patients. Results: Two hundred six patients (91%) were retreated with curative intent, and 173 had HNSCC histology; 104 (50%) underwent salvage resection, and 135 (66%) received chemotherapy. Median follow-up after reirradiation was 24.7 months. Clinical outcomes were worse for HNSCC patients, with 5-year locoregional control, progression-free survival, and overall survival rates of 53%, 22%, and 32%, respectively, compared with 74%, 59%, and 79%, respectively, for non-HNSCC patients. On multivariate analysis, concurrent chemotherapy and retreatment site were associated with tumor control, whereas performance status was associated with survival. Favorable prognostic factors specific to surgery patients were neck retreatment and lack of extracapsular extension, whereas for nonsurgery patients, these were a nasopharynx subsite and complete response to induction chemotherapy. Actuarial rates of grade ≥3 toxicity were 32% at 2 years and 48% at 5 years, with dysphagia or odynophagia being most common. Increased grade ≥3 toxicity was associated with retreatment volume >50 cm{sup 3} and concurrent chemotherapy. Conclusions: Reirradiation with IMRT either definitively or after salvage surgery can produce promising local control and survival in selected patients with head and neck

  7. Image Guided Hypofractionated Postprostatectomy Intensity Modulated Radiation Therapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Stephen L.; Patel, Pretesh; Song, Haijun [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Freedland, Stephen J. [Surgery Section, Durham Veterans Administration, and Division of Urology, Department of Surgery, Cedars-Sinai Medical Center, Los Angeles, California (United States); Bynum, Sigrun; Oh, Daniel; Palta, Manisha; Yoo, David; Oleson, James [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Salama, Joseph K., E-mail: joseph.salama@duke.edu [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States)

    2016-03-01

    Purpose: Hypofractionated radiation therapy (RT) has promising long-term biochemical relapse-free survival (bRFS) with comparable toxicity for definitive treatment of prostate cancer. However, data reporting outcomes after adjuvant and salvage postprostatectomy hypofractionated RT are sparse. Therefore, we report the toxicity and clinical outcomes after postprostatectomy hypofractionated RT. Methods and Materials: From a prospectively maintained database, men receiving image guided hypofractionated intensity modulated RT (HIMRT) with 2.5-Gy fractions constituted our study population. Androgen deprivation therapy was used at the discretion of the radiation oncologist. Acute toxicities were graded according to the Common Terminology Criteria for Adverse Events version 4.0. Late toxicities were scored using the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer scale. Biochemical recurrence was defined as an increase of 0.1 in prostate-specific antigen (PSA) from posttreatment nadir or an increase in PSA despite treatment. The Kaplan-Meier method was used for the time-to-event outcomes. Results: Between April 2008 and April 2012, 56 men received postoperative HIMRT. The median follow-up time was 48 months (range, 21-67 months). Thirty percent had pre-RT PSA <0.1; the median pre-RT detectable PSA was 0.32 ng/mL. The median RT dose was 65 Gy (range, 57.5-65 Gy). Ten patients received neoadjuvant and concurrent hormone therapy. Posttreatment acute urinary toxicity was limited. There was no acute grade 3 toxicity. Late genitourinary (GU) toxicity of any grade was noted in 52% of patients, 40% of whom had pre-RT urinary incontinence. The 4-year actuarial rate of late grade 3 GU toxicity (exclusively gross hematuria) was 28% (95% confidence interval [CI], 16%-41%). Most grade 3 GU toxicity resolved; only 7% had persistent grade ≥3 toxicity at the last follow-up visit. Fourteen patients experienced biochemical recurrence at a

  8. Disease Control After Reduced Volume Conformal and Intensity Modulated Radiation Therapy for Childhood Craniopharyngioma

    Energy Technology Data Exchange (ETDEWEB)

    Merchant, Thomas E., E-mail: thomas.merchant@stjude.org [St Jude Children' s Research Hospital, Radiological Sciences, Memphis, Tennessee (United States); Kun, Larry E.; Hua, Chia-Ho [St Jude Children' s Research Hospital, Radiological Sciences, Memphis, Tennessee (United States); Wu, Shengjie; Xiong, Xiaoping [St Jude Children' s Research Hospital, Biostatistics, Memphis, Tennessee (United States); Sanford, Robert A.; Boop, Frederick A. [Semmes Murphey Neurologic and Spine Institute, Neurosurgery, Memphis, Tennessee (United States)

    2013-03-15

    Purpose: To estimate the rate of disease control after conformal radiation therapy using reduced clinical target volume (CTV) margins and to determine factors that predict for tumor progression. Methods and Materials: Eighty-eight children (median age, 8.5 years; range, 3.2-17.6 years) received conformal or intensity modulated radiation therapy between 1998 and 2009. The study group included those prospectively treated from 1998 to 2003, using a 10-mm CTV, defined as the margin surrounding the solid and cystic tumor targeted to receive the prescription dose of 54 Gy. The CTV margin was subsequently reduced after 2003, yielding 2 groups of patients: those treated with a CTV margin greater than 5 mm (n=26) and those treated with a CTV margin less than or equal to 5 mm (n=62). Disease progression was estimated on the basis of additional variables including sex, race, extent of resection, tumor interventions, target volume margins, and frequency of weekly surveillance magnetic resonance (MR) imaging during radiation therapy. Median follow-up was 5 years. Results: There was no difference between progression-free survival rates based on CTV margins (>5 mm vs ≤5 mm) at 5 years (88.1% ± 6.3% vs 96.2% ± 4.4% [P=.6386]). There were no differences based on planning target volume (PTV) margins (or combined CTV plus PTV margins). The PTV was systematically reduced from 5 to 3 mm during the time period of the study. Factors predictive of superior progression-free survival included Caucasian race (P=.0175), no requirement for cerebrospinal fluid shunting (P=.0066), and number of surveillance imaging studies during treatment (P=.0216). Patients whose treatment protocol included a higher number of weekly surveillance MR imaging evaluations had a lower rate of tumor progression. Conclusions: These results suggest that targeted volume reductions for radiation therapy using smaller margins are feasible and safe but require careful monitoring. We are currently investigating

  9. Mixed modality intensity-modulated radiation therapy treatment planning for intracranial lesions

    International Nuclear Information System (INIS)

    Lee, Henry J.; Forster, Kenneth M.; Sheldon, John M.; Wood, Rudy R.; Spirou, Spiridon V.; Burman, Chandra M.; Chui, Chen-Shou; Fuks, Zvi Y.; Ling, Clifton C.; Kutcher, Gerald J.; Leibel, Steven A.

    1997-01-01

    Purpose: Intensity-modulated radiotherapy may be improved by incorporating limited-range electrons into photon beam therapy. We examined the feasibility of inverse treatment planning with intensity-modulated photon fields, either alone or combined with uniform high-energy electron fields, for intracranial tumors. Our goal was to generate dose distributions superior to those generated with conventional three-dimensional conformal techniques. Materials and Methods: Optimized three-dimensional treatment plans were compared to intensity-modulated photon plans with and without unmodulated high-energy electron fields for a cohort of previously treated brain tumors. Our in-house optimization system employed an iterative conjugate gradient search algorithm for cost function minimizing. Each set of plans was constrained to identical dose volume limits for critical non-target structures and dose prescription specifications for the planning target volume. In addition, each set used almost identical photon beam orientations to facilitate comparisons (for intensity-modulated plans, parallel opposed fields were slightly off-set to more effectively utilize the dosimetric advantages of inverse planning). Dosimetric comparisons were performed by examining planar and volumetric isodose distributions as well as dose-volume histograms. In particular, differences in integral dose to non-target brain tissue were evaluated. All plans were designed for implementation on a standard Varian 2100C with dynamic multileaf capability. Results: Peripheral targets demonstrated the greatest benefit from mixed modality intensity-modulated treatment planning. The principle dosimetric advantage was a decreased integral dose to the normal brain when calculated by taking a first moment integral of a differential dose volume histogram of normal brain tissue. The majority of this benefit was typically achieved through at least a 50% reduction in the volume of normal tissue receiving more than 80% of the

  10. Automatically-generated rectal dose constraints in intensity-modulated radiation therapy for prostate cancer

    Science.gov (United States)

    Hwang, Taejin; Kim, Yong Nam; Kim, Soo Kon; Kang, Sei-Kwon; Cheong, Kwang-Ho; Park, Soah; Yoon, Jai-Woong; Han, Taejin; Kim, Haeyoung; Lee, Meyeon; Kim, Kyoung-Joo; Bae, Hoonsik; Suh, Tae-Suk

    2015-06-01

    The dose constraint during prostate intensity-modulated radiation therapy (IMRT) optimization should be patient-specific for better rectum sparing. The aims of this study are to suggest a novel method for automatically generating a patient-specific dose constraint by using an experience-based dose volume histogram (DVH) of the rectum and to evaluate the potential of such a dose constraint qualitatively. The normal tissue complication probabilities (NTCPs) of the rectum with respect to V %ratio in our study were divided into three groups, where V %ratio was defined as the percent ratio of the rectal volume overlapping the planning target volume (PTV) to the rectal volume: (1) the rectal NTCPs in the previous study (clinical data), (2) those statistically generated by using the standard normal distribution (calculated data), and (3) those generated by combining the calculated data and the clinical data (mixed data). In the calculated data, a random number whose mean value was on the fitted curve described in the clinical data and whose standard deviation was 1% was generated by using the `randn' function in the MATLAB program and was used. For each group, we validated whether the probability density function (PDF) of the rectal NTCP could be automatically generated with the density estimation method by using a Gaussian kernel. The results revealed that the rectal NTCP probability increased in proportion to V %ratio , that the predictive rectal NTCP was patient-specific, and that the starting point of IMRT optimization for the given patient might be different. The PDF of the rectal NTCP was obtained automatically for each group except that the smoothness of the probability distribution increased with increasing number of data and with increasing window width. We showed that during the prostate IMRT optimization, the patient-specific dose constraints could be automatically generated and that our method could reduce the IMRT optimization time as well as maintain the

  11. Individualized Selection of Beam Angles and Treatment Isocenter in Tangential Breast Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Penninkhof, Joan, E-mail: j.penninkhof@erasmusmc.nl [Department of Radiation Oncology, Erasmus M.C. Cancer Institute, Rotterdam (Netherlands); Spadola, Sara [Department of Radiation Oncology, Erasmus M.C. Cancer Institute, Rotterdam (Netherlands); Department of Physics and Astronomy, Alma Mater Studiorum, University of Bologna, Bologna (Italy); Breedveld, Sebastiaan; Baaijens, Margreet [Department of Radiation Oncology, Erasmus M.C. Cancer Institute, Rotterdam (Netherlands); Lanconelli, Nico [Department of Physics and Astronomy, Alma Mater Studiorum, University of Bologna, Bologna (Italy); Heijmen, Ben [Department of Radiation Oncology, Erasmus M.C. Cancer Institute, Rotterdam (Netherlands)

    2017-06-01

    Purpose and Objective: Propose a novel method for individualized selection of beam angles and treatment isocenter in tangential breast intensity modulated radiation therapy (IMRT). Methods and Materials: For each patient, beam and isocenter selection starts with the fully automatic generation of a large database of IMRT plans (up to 847 in this study); each of these plans belongs to a unique combination of isocenter position, lateral beam angle, and medial beam angle. The imposed hard planning constraint on patient maximum dose may result in plans with unacceptable target dose delivery. Such plans are excluded from further analyses. Owing to differences in beam setup, database plans differ in mean doses to organs at risk (OARs). These mean doses are used to construct 2-dimensional graphs, showing relationships between: (1) contralateral breast dose and ipsilateral lung dose; and (2) contralateral breast dose and heart dose (analyzed only for left-sided). The graphs can be used for selection of the isocenter and beam angles with the optimal, patient-specific tradeoffs between the mean OAR doses. For 30 previously treated patients (15 left-sided and 15 right-sided tumors), graphs were generated considering only the clinically applied isocenter with 121 tangential beam angle pairs. For 20 of the 30 patients, 6 alternative isocenters were also investigated. Results: Computation time for automatic generation of 121 IMRT plans took on average 30 minutes. The generated graphs demonstrated large variations in tradeoffs between conflicting OAR objectives, depending on beam angles and patient anatomy. For patients with isocenter optimization, 847 IMRT plans were considered. Adding isocenter position optimization next to beam angle optimization had a small impact on the final plan quality. Conclusion: A method is proposed for individualized selection of beam angles in tangential breast IMRT. This may be especially important for patients with cardiac risk factors or an

  12. Replanning During Intensity Modulated Radiation Therapy Improved Quality of Life in Patients With Nasopharyngeal Carcinoma

    International Nuclear Information System (INIS)

    Yang Haihua; Hu Wei; Wang Wei; Chen Peifang; Ding Weijun; Luo Wei

    2013-01-01

    Purpose: Anatomic and dosimetric changes have been reported during intensity modulated radiation therapy (IMRT) in patients with nasopharyngeal carcinoma (NPC). The purpose of this study was to evaluate the effects of replanning on quality of life (QoL) and clinical outcomes during the course of IMRT for NPC patients. Methods and Materials: Between June 2007 and August 2011, 129 patients with NPC were enrolled. Forty-three patients received IMRT without replanning, while 86 patients received IMRT replanning after computed tomography (CT) images were retaken part way through therapy. Chinese versions of the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire C30 and Head and Neck Quality of Life Questionnaire 35 were completed before treatment began and at the end of treatment and at 1, 3, 6, and 12 months after the completion of treatment. Overall survival (OS) data were compared using the Kaplan-Meier method. Results: IMRT replanning had a profound impact on the QoL of NPC patients, as determined by statistically significant changes in global QoL and other QoL scales. Additionally, the clinical outcome comparison indicates that replanning during IMRT for NPC significantly improved 2-year local regional control (97.2% vs 92.4%, respectively, P=.040) but did not improve 2-year OS (89.8% vs 82.2%, respectively, P=.475). Conclusions: IMRT replanning improves QoL as well as local regional control in patients with NPC. Future research is needed to determine the criteria for replanning for NPC patients undergoing IMRT.

  13. Patterns of Disease Recurrence Following Treatment of Oropharyngeal Cancer With Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Garden, Adam S., E-mail: agarden@mdanderson.org [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Dong, Lei [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Morrison, William H. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Stugis, Erich M. [Department of Head and Neck Surgery, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Department of Epidemiology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Glisson, Bonnie S. [Department of Thoracic/Head and Neck Medicine, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Frank, Steven J.; Beadle, Beth M.; Gunn, Gary B. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Schwartz, David L. [Department of Radiation Medicine, Long Island Jewish Medical Center, New Hyde Park, NY (United States); Kies, Merill S. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Department of Thoracic/Head and Neck Medicine, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Weber, Randal S. [Department of Head and Neck Surgery, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Ang, K. Kian; Rosenthal, David I. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2013-03-15

    Purpose: To report mature results of a large cohort of patients diagnosed with squamous cell carcinoma of the oropharynx who were treated with intensity modulated radiation therapy (IMRT). Methods and Materials: The database of patients irradiated at The University of Texas, M.D. Anderson Cancer Center was searched for patients diagnosed with oropharyngeal cancer and treated with IMRT between 2000 and 2007. A retrospective review of outcome data was performed. Results: The cohort consisted of 776 patients. One hundred fifty-nine patients (21%) were current smokers, 279 (36%) former smokers, and 337 (43%) never smokers. T and N categories and American Joint Committee on Cancer group stages were distributed as follows: T1/x, 288 (37%); T2, 288 (37%); T3, 113 (15%); T4, 87 (11%); N0, 88(12%); N1/x, 140 (18%); N2a, 101 (13%); N2b, 269 (35%); N2c, 122 (16%); and N3, 56 (7%); stage I, 18(2%); stage II, 40(5%); stage III, 150(19%); and stage IV, 568(74%). Seventy-one patients (10%) presented with nodes in level IV. Median follow-up was 54 months. The 5-year overall survival, locoregional control, and overall recurrence-free survival rates were 84%, 90%, and 82%, respectively. Primary site recurrence developed in 7% of patients, and neck recurrence with primary site control in 3%. We could only identify 12 patients (2%) who had locoregional recurrence outside the high-dose target volumes. Poorer survival rates were observed in current smokers, patients with larger primary (T) tumors and lower neck disease. Conclusions: Patients with oropharyngeal cancer treated with IMRT have excellent disease control. Locoregional recurrence was uncommon, and most often occurred in the high dose volumes. Parotid sparing was accomplished in nearly all patients without compromising tumor coverage.

  14. An Anatomically Validated Brachial Plexus Contouring Method for Intensity Modulated Radiation Therapy Planning

    Energy Technology Data Exchange (ETDEWEB)

    Van de Velde, Joris, E-mail: joris.vandevelde@ugent.be [Department of Anatomy, Ghent University, Ghent (Belgium); Department of Radiotherapy, Ghent University, Ghent (Belgium); Audenaert, Emmanuel [Department of Physical Medicine and Orthopedic Surgery, Ghent University, Ghent (Belgium); Speleers, Bruno; Vercauteren, Tom; Mulliez, Thomas [Department of Radiotherapy, Ghent University, Ghent (Belgium); Vandemaele, Pieter; Achten, Eric [Department of Radiology, Ghent University, Ghent (Belgium); Kerckaert, Ingrid; D' Herde, Katharina [Department of Anatomy, Ghent University, Ghent (Belgium); De Neve, Wilfried [Department of Radiotherapy, Ghent University, Ghent (Belgium); Van Hoof, Tom [Department of Anatomy, Ghent University, Ghent (Belgium)

    2013-11-15

    Purpose: To develop contouring guidelines for the brachial plexus (BP) using anatomically validated cadaver datasets. Magnetic resonance imaging (MRI) and computed tomography (CT) were used to obtain detailed visualizations of the BP region, with the goal of achieving maximal inclusion of the actual BP in a small contoured volume while also accommodating for anatomic variations. Methods and Materials: CT and MRI were obtained for 8 cadavers positioned for intensity modulated radiation therapy. 3-dimensional reconstructions of soft tissue (from MRI) and bone (from CT) were combined to create 8 separate enhanced CT project files. Dissection of the corresponding cadavers anatomically validated the reconstructions created. Seven enhanced CT project files were then automatically fitted, separately in different regions, to obtain a single dataset of superimposed BP regions that incorporated anatomic variations. From this dataset, improved BP contouring guidelines were developed. These guidelines were then applied to the 7 original CT project files and also to 1 additional file, left out from the superimposing procedure. The percentage of BP inclusion was compared with the published guidelines. Results: The anatomic validation procedure showed a high level of conformity for the BP regions examined between the 3-dimensional reconstructions generated and the dissected counterparts. Accurate and detailed BP contouring guidelines were developed, which provided corresponding guidance for each level in a clinical dataset. An average margin of 4.7 mm around the anatomically validated BP contour is sufficient to accommodate for anatomic variations. Using the new guidelines, 100% inclusion of the BP was achieved, compared with a mean inclusion of 37.75% when published guidelines were applied. Conclusion: Improved guidelines for BP delineation were developed using combined MRI and CT imaging with validation by anatomic dissection.

  15. Intensity-modulated radiation therapy for T4 nasopharyngeal carcinoma. Treatment results and locoregional

    Energy Technology Data Exchange (ETDEWEB)

    Chen, J.L.Y.; Tsai, C.L.; Chen, W.Y.; Wang, C.W. [National Taiwan Univ. Hospital, Taipei (China). Div. of Radiation Oncology; Huang, Y.S.; Chen, Y.F. [National Taiwan Univ. Hospital, Taipei (China). Dept. of Medical Imaging; Kuo, S.H. [National Taiwan Univ. Hospital, Taipei (China). Div. of Radiation Oncology; National Taiwan Univ. College of Medicine, Taipei (China). Graduate Inst. of Clinical Medicine; Hong, R.L. [National Taiwan Univ. Hospital, Taipei (China). Div. of Medical Oncology; Ko, J.Y.; Lou, P.J. [National Taiwan Univ. Hospital, Taipei (China). Dept. of Otolaryngology

    2013-12-15

    Purpose: The purpose of this work was to examine outcomes in patients with T4 nasopharyngeal carcinoma (NPC) treated with intensity-modulated radiation therapy (IMRT). Methods and materials: Between 2007 and 2010, 154 patients with nonmetastatic T4 NPC were treated with IMRT to a total dose of 70 Gy in 33-35 fractions. In addition, 97 % of patients received concurrent platinum-based chemotherapy. The median follow-up time was 52.8 months. Results: The rates of 5-year actuarial locoregional control, distant metastasis-free survival, progression free-survival, and overall survival (OS) were 81.2, 72.2, 61.9, and 78.1 %, respectively. A total of 27 patients had locoregional recurrence: 85.2 % in-field failures, 11.1 % marginal failures, and 3.7 % out-of-field failures. Fourteen patients with locoregional recurrence received aggressive treatments, including nasopharyngectomy, neck dissection, or re-irradiation, and the 5-year OS rate tended to be better (61.9 %) compared to those receiving conservative treatment (32.0 %, p = 0.051). In patients treated with 1 course of radiotherapy, grade {>=} 3 toxicities of ototoxicity, neck fibrosis, xerostomia, epistaxis, and radiographic temporal lobe necrosis occurred in 18.2, 9.8, 6.3, 2.1, and 5.6 % of patients, respectively. Increased ototoxicity, osteonecrosis, severe nasal bleeding, and temporal necrosis were observed in patients treated by re-irradiation. Conclusion: IMRT offers good locoregional control in patients with T4 NPC. For patients with locoregional recurrence after definitive radiotherapy, aggressive local treatment may be considered for a better outcome. (orig.)

  16. HybridArc: A novel radiation therapy technique combining optimized dynamic arcs and intensity modulation

    Energy Technology Data Exchange (ETDEWEB)

    Robar, James L., E-mail: james.robar@cdha.nshealth.ca [Department of Radiation Oncology, Dalhousie University, Halifax (Canada); Department of Physics and Atmospheric Science, Dalhousie University, Halifax (Canada); Thomas, Christopher [Department of Radiation Oncology, Dalhousie University, Halifax (Canada)

    2012-01-01

    This investigation focuses on possible dosimetric and efficiency advantages of HybridArc-a novel treatment planning approach combining optimized dynamic arcs with intensity-modulated radiation therapy (IMRT) beams. Application of this technique to two disparate sites, complex cranial tumors, and prostate was examined. HybridArc plans were compared with either dynamic conformal arc (DCA) or IMRT plans to determine whether HybridArc offers a synergy through combination of these 2 techniques. Plans were compared with regard to target volume dose conformity, target volume dose homogeneity, sparing of proximal organs at risk, normal tissue sparing, and monitor unit (MU) efficiency. For cranial cases, HybridArc produced significantly improved dose conformity compared with both DCA and IMRT but did not improve sparing of the brainstem or optic chiasm. For prostate cases, conformity was improved compared with DCA but not IMRT. Compared with IMRT, the dose homogeneity in the planning target volume was improved, and the maximum doses received by the bladder and rectum were reduced. Both arc-based techniques distribute peripheral dose over larger volumes of normal tissue compared with IMRT, whereas HybridArc involved slightly greater volumes of normal tissues compared with DCA. Compared with IMRT, cranial cases required 38% more MUs, whereas for prostate cases, MUs were reduced by 7%. For cranial cases, HybridArc improves dose conformity to the target. For prostate cases, dose conformity and homogeneity are improved compared with DCA and IMRT, respectively. Compared with IMRT, whether required MUs increase or decrease with HybridArc was site-dependent.

  17. Automation and Intensity Modulated Radiation Therapy for Individualized High-Quality Tangent Breast Treatment Plans

    International Nuclear Information System (INIS)

    Purdie, Thomas G.; Dinniwell, Robert E.; Fyles, Anthony; Sharpe, Michael B.

    2014-01-01

    Purpose: To demonstrate the large-scale clinical implementation and performance of an automated treatment planning methodology for tangential breast intensity modulated radiation therapy (IMRT). Methods and Materials: Automated planning was used to prospectively plan tangential breast IMRT treatment for 1661 patients between June 2009 and November 2012. The automated planning method emulates the manual steps performed by the user during treatment planning, including anatomical segmentation, beam placement, optimization, dose calculation, and plan documentation. The user specifies clinical requirements of the plan to be generated through a user interface embedded in the planning system. The automated method uses heuristic algorithms to define and simplify the technical aspects of the treatment planning process. Results: Automated planning was used in 1661 of 1708 patients receiving tangential breast IMRT during the time interval studied. Therefore, automated planning was applicable in greater than 97% of cases. The time for treatment planning using the automated process is routinely 5 to 6 minutes on standard commercially available planning hardware. We have shown a consistent reduction in plan rejections from plan reviews through the standard quality control process or weekly quality review multidisciplinary breast rounds as we have automated the planning process for tangential breast IMRT. Clinical plan acceptance increased from 97.3% using our previous semiautomated inverse method to 98.9% using the fully automated method. Conclusions: Automation has become the routine standard method for treatment planning of tangential breast IMRT at our institution and is clinically feasible on a large scale. The method has wide clinical applicability and can add tremendous efficiency, standardization, and quality to the current treatment planning process. The use of automated methods can allow centers to more rapidly adopt IMRT and enhance access to the documented

  18. Multi-GPU configuration of 4D intensity modulated radiation therapy inverse planning using global optimization

    Science.gov (United States)

    Hagan, Aaron; Sawant, Amit; Folkerts, Michael; Modiri, Arezoo

    2018-01-01

    We report on the design, implementation and characterization of a multi-graphic processing unit (GPU) computational platform for higher-order optimization in radiotherapy treatment planning. In collaboration with a commercial vendor (Varian Medical Systems, Palo Alto, CA), a research prototype GPU-enabled Eclipse (V13.6) workstation was configured. The hardware consisted of dual 8-core Xeon processors, 256 GB RAM and four NVIDIA Tesla K80 general purpose GPUs. We demonstrate the utility of this platform for large radiotherapy optimization problems through the development and characterization of a parallelized particle swarm optimization (PSO) four dimensional (4D) intensity modulated radiation therapy (IMRT) technique. The PSO engine was coupled to the Eclipse treatment planning system via a vendor-provided scripting interface. Specific challenges addressed in this implementation were (i) data management and (ii) non-uniform memory access (NUMA). For the former, we alternated between parameters over which the computation process was parallelized. For the latter, we reduced the amount of data required to be transferred over the NUMA bridge. The datasets examined in this study were approximately 300 GB in size, including 4D computed tomography images, anatomical structure contours and dose deposition matrices. For evaluation, we created a 4D-IMRT treatment plan for one lung cancer patient and analyzed computation speed while varying several parameters (number of respiratory phases, GPUs, PSO particles, and data matrix sizes). The optimized 4D-IMRT plan enhanced sparing of organs at risk by an average reduction of 26% in maximum dose, compared to the clinical optimized IMRT plan, where the internal target volume was used. We validated our computation time analyses in two additional cases. The computation speed in our implementation did not monotonically increase with the number of GPUs. The optimal number of GPUs (five, in our study) is directly related to the

  19. Replanning during intensity modulated radiation therapy improved quality of life in patients with nasopharyngeal carcinoma.

    Science.gov (United States)

    Yang, Haihua; Hu, Wei; Wang, Wei; Chen, Peifang; Ding, Weijun; Luo, Wei

    2013-01-01

    Anatomic and dosimetric changes have been reported during intensity modulated radiation therapy (IMRT) in patients with nasopharyngeal carcinoma (NPC). The purpose of this study was to evaluate the effects of replanning on quality of life (QoL) and clinical outcomes during the course of IMRT for NPC patients. Between June 2007 and August 2011, 129 patients with NPC were enrolled. Forty-three patients received IMRT without replanning, while 86 patients received IMRT replanning after computed tomography (CT) images were retaken part way through therapy. Chinese versions of the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire C30 and Head and Neck Quality of Life Questionnaire 35 were completed before treatment began and at the end of treatment and at 1, 3, 6, and 12 months after the completion of treatment. Overall survival (OS) data were compared using the Kaplan-Meier method. IMRT replanning had a profound impact on the QoL of NPC patients, as determined by statistically significant changes in global QoL and other QoL scales. Additionally, the clinical outcome comparison indicates that replanning during IMRT for NPC significantly improved 2-year local regional control (97.2% vs 92.4%, respectively, P=.040) but did not improve 2-year OS (89.8% vs 82.2%, respectively, P=.475). IMRT replanning improves QoL as well as local regional control in patients with NPC. Future research is needed to determine the criteria for replanning for NPC patients undergoing IMRT. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Intensity-modulated radiation therapy for T4 nasopharyngeal carcinoma. Treatment results and locoregional

    International Nuclear Information System (INIS)

    Chen, J.L.Y.; Tsai, C.L.; Chen, W.Y.; Wang, C.W.; Huang, Y.S.; Chen, Y.F.; Kuo, S.H.; National Taiwan Univ. College of Medicine, Taipei; Hong, R.L.; Ko, J.Y.; Lou, P.J.

    2013-01-01

    Purpose: The purpose of this work was to examine outcomes in patients with T4 nasopharyngeal carcinoma (NPC) treated with intensity-modulated radiation therapy (IMRT). Methods and materials: Between 2007 and 2010, 154 patients with nonmetastatic T4 NPC were treated with IMRT to a total dose of 70 Gy in 33-35 fractions. In addition, 97 % of patients received concurrent platinum-based chemotherapy. The median follow-up time was 52.8 months. Results: The rates of 5-year actuarial locoregional control, distant metastasis-free survival, progression free-survival, and overall survival (OS) were 81.2, 72.2, 61.9, and 78.1 %, respectively. A total of 27 patients had locoregional recurrence: 85.2 % in-field failures, 11.1 % marginal failures, and 3.7 % out-of-field failures. Fourteen patients with locoregional recurrence received aggressive treatments, including nasopharyngectomy, neck dissection, or re-irradiation, and the 5-year OS rate tended to be better (61.9 %) compared to those receiving conservative treatment (32.0 %, p = 0.051). In patients treated with 1 course of radiotherapy, grade ≥ 3 toxicities of ototoxicity, neck fibrosis, xerostomia, epistaxis, and radiographic temporal lobe necrosis occurred in 18.2, 9.8, 6.3, 2.1, and 5.6 % of patients, respectively. Increased ototoxicity, osteonecrosis, severe nasal bleeding, and temporal necrosis were observed in patients treated by re-irradiation. Conclusion: IMRT offers good locoregional control in patients with T4 NPC. For patients with locoregional recurrence after definitive radiotherapy, aggressive local treatment may be considered for a better outcome. (orig.)

  1. Beam orientation optimization for intensity-modulated radiation therapy using mixed integer programming

    Energy Technology Data Exchange (ETDEWEB)

    Yang Ruijie [Department of Radiation Oncology, Cancer Hospital (Institute), Chinese Academy of Medical Sciences/Peking Union Medical College, PO Box 2258, Beijing 100021 (China); Dai Jianrong [Department of Radiation Oncology, Cancer Hospital (Institute), Chinese Academy of Medical Sciences/Peking Union Medical College, PO Box 2258, Beijing 100021 (China); Yang Yong [Department of Radiation Oncology, University of Pittsburgh Medical Center, Pittsburgh, PA 15232 (United States); Hu Yimin [Department of Radiation Oncology, Cancer Hospital (Institute), Chinese Academy of Medical Sciences/Peking Union Medical College, PO Box 2258, Beijing 100021 (China)

    2006-08-07

    The purpose of this study is to extend an algorithm proposed for beam orientation optimization in classical conformal radiotherapy to intensity-modulated radiation therapy (IMRT) and to evaluate the algorithm's performance in IMRT scenarios. In addition, the effect of the candidate pool of beam orientations, in terms of beam orientation resolution and starting orientation, on the optimized beam configuration, plan quality and optimization time is also explored. The algorithm is based on the technique of mixed integer linear programming in which binary and positive float variables are employed to represent candidates for beam orientation and beamlet weights in beam intensity maps. Both beam orientations and beam intensity maps are simultaneously optimized in the algorithm with a deterministic method. Several different clinical cases were used to test the algorithm and the results show that both target coverage and critical structures sparing were significantly improved for the plans with optimized beam orientations compared to those with equi-spaced beam orientations. The calculation time was less than an hour for the cases with 36 binary variables on a PC with a Pentium IV 2.66 GHz processor. It is also found that decreasing beam orientation resolution to 10{sup 0} greatly reduced the size of the candidate pool of beam orientations without significant influence on the optimized beam configuration and plan quality, while selecting different starting orientations had large influence. Our study demonstrates that the algorithm can be applied to IMRT scenarios, and better beam orientation configurations can be obtained using this algorithm. Furthermore, the optimization efficiency can be greatly increased through proper selection of beam orientation resolution and starting beam orientation while guaranteeing the optimized beam configurations and plan quality.

  2. Application of influence diagrams to prostate intensity-modulated radiation therapy plan selection

    Science.gov (United States)

    Meyer, Jürgen; Phillips, Mark H.; Cho, Paul S.; Kalet, Ira; Doctor, Jason N.

    2004-05-01

    The purpose is to incorporate clinically relevant factors such as patient-specific and dosimetric information as well as data from clinical trials in the decision-making process for the selection of prostate intensity-modulated radiation therapy (IMRT) plans. The approach is to incorporate the decision theoretic concept of an influence diagram into the solution of the multiobjective optimization inverse planning problem. A set of candidate IMRT plans was obtained by varying the importance factors for the planning target volume (PTV) and the organ-at-risk (OAR) in combination with simulated annealing to explore a large part of the solution space. The Pareto set for the PTV and OAR was analysed to demonstrate how the selection of the weighting factors influenced which part of the solution space was explored. An influence diagram based on a Bayesian network with 18 nodes was designed to model the decision process for plan selection. The model possessed nodes for clinical laboratory results, tumour grading, staging information, patient-specific information, dosimetric information, complications and survival statistics from clinical studies. A utility node was utilized for the decision-making process. The influence diagram successfully ranked the plans based on the available information. Sensitivity analyses were used to judge the reasonableness of the diagram and the results. In conclusion, influence diagrams lend themselves well to modelling the decision processes for IMRT plan selection. They provide an excellent means to incorporate the probabilistic nature of data and beliefs into one model. They also provide a means for introducing evidence-based medicine, in the form of results of clinical trials, into the decision-making process.

  3. Clinical Value of [{sup 11}C]Methionine PET for Stereotactic Radiation Therapy With Intensity Modulated Radiation Therapy to Metastatic Brain Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Miwa, Kazuhiro, E-mail: doctor.3@jasmine.ocn.ne.jp [Chubu Medical Center for Prolonged Traumatic Brain Dysfunction, Kizawa Memorial Hospital, Minokamo, Gifu (Japan); Department of Clinical Brain Sciences, Gifu University Graduate School of Medicine, Minokamo, Gifu (Japan); Matsuo, Masayuki [Department of Radiation Oncology, Kizawa Memorial Hospital, Minokamo, Gifu (Japan); Shinoda, Jun; Aki, Tatsuki; Yonezawa, Shingo [Chubu Medical Center for Prolonged Traumatic Brain Dysfunction, Kizawa Memorial Hospital, Minokamo, Gifu (Japan); Department of Clinical Brain Sciences, Gifu University Graduate School of Medicine, Minokamo, Gifu (Japan); Ito, Takeshi [Department of Neurosurgery, Kizawa Memorial Hospital, Minokamo, Gifu (Japan); Asano, Yoshitaka [Chubu Medical Center for Prolonged Traumatic Brain Dysfunction, Kizawa Memorial Hospital, Minokamo, Gifu (Japan); Department of Clinical Brain Sciences, Gifu University Graduate School of Medicine, Minokamo, Gifu (Japan); Yamada, Mikito; Yokoyama, Kazutoshi; Yamada, Jitsuhiro [Department of Neurosurgery, Kizawa Memorial Hospital, Minokamo, Gifu (Japan); Yano, Hirohito; Iwama, Toru [Department of Neurosurgery, Gifu University Graduate School of Medicine, Gifu (Japan)

    2012-12-01

    Purpose: This study investigated the clinical impact of {sup 11}C-labeled methionine-positron emission tomography (MET-PET) for stereotactic radiation therapy with intensity modulated radiation therapy (SRT-IMRT) in metastatic brain tumors. Methods and Materials: Forty-two metastatic brain tumors were examined. All tumors were treated with SRT-IMRT using a helical tomotherapy system. Gross tumor volume (GTV) was defined and drawn on the stereotactic magnetic resonance (MR) image, taking into account the respective contributions of MR imaging and MET-PET. Planning target volume (PTV) encompassed the GTV-PET plus a 2-mm margin. SRT-IMRT was performed, keeping the dose for PTV at 25-35 Gy in 5 fractions. The ratio of the mean value of MET uptake to the contralateral normal brain (L/N ratio) was plotted for the PTV prior to SRT-IMRT, at 3 months following SRT-IMRT, and at 6 months following SRT-IMRT. Tumor characteristic changes of MET uptake before and after SRT-IMRT were evaluated quantitatively, comparing them with MRI examination. Results: Mean {+-} SD L/N ratios were 1.95 {+-} 0.83, 1.18 {+-} 0.21, and 1.12 {+-} 0.25 in the pre-SRT-IMRT group, in the 3 months post-SRT-IMRT group, and in the 6 months post-SRT-IMRT group, respectively. Differences in the mean L/N ratio between the pre-SRT-IMRT group and the 3-month post-SRT-IMRT group and between the pre-SRT-IMRT group and the 6 month post-SRT-IMRT group were statistically significant, irrespective of MRI examination. Conclusions: We showed examples of metastatic lesions demonstrating significant decreases in MET uptake following SRT-IMRT. MET-PET seems to have a potential role in providing additional information, although MRI remains the gold standard for diagnosis and follow-up after SRT-IMRT. The present study is a preliminary approach, but to more clearly define the impact of PET-based radiosurgical assessment, further experimental and clinical analyses are required.

  4. Direct aperture optimization as a means of reducing the complexity of intensity modulated radiation therapy plans

    Directory of Open Access Journals (Sweden)

    Coffey Mary

    2009-02-01

    Full Text Available Abstract Intensity Modulated Radiation Therapy (IMRT is a means of delivering radiation therapy where the intensity of the beam is varied within the treatment field. This is done by dividing a large beam into many small beamlets. Dose constraints are assigned to both the target and sensitive structures and computerised inverse optimization is performed to find the individual weights of this large number of beamlets. The computer adjusts the intensities of these beamlets according to the required planning dose objectives. The optimized intensity patterns are then decomposed into a series of deliverable multi leaf collimator (MLC shapes in the sequencing step. One of the main problems of IMRT, which becomes even more apparent as the complexity of the IMRT plan increases, is the dramatic increase in the number of Monitor Units (MU required to deliver a fractionated treatment. The difficulty with this increase in MU is its association with increased treatment times and a greater leakage of radiation from the MLCs increasing the total body dose and the risk of secondary cancers in patients. Therefore one attempts to find ways of reducing these MU without compromising plan quality. The design of inverse planning systems where the beam is divided into small beamlets to produce the required intensity map automatically introduces complexity into IMRT treatment planning. Plan complexity is associated with many negative factors such as dosimetric uncertainty and delivery issues A large search space is required necessitating much computing power. However, the limitations of the delivery technology are not taken into consideration when designing the ideal intensity map therefore a further step termed the sequencing step is required to convert the ideal intensity map into a deliverable one. Many approaches have been taken to reduce the complexity. These include setting intensity limits, putting penalties on the cost function and using smoothing filters Direct

  5. Direct aperture optimization as a means of reducing the complexity of intensity modulated radiation therapy plans

    International Nuclear Information System (INIS)

    Broderick, Maria; Leech, Michelle; Coffey, Mary

    2009-01-01

    Intensity Modulated Radiation Therapy (IMRT) is a means of delivering radiation therapy where the intensity of the beam is varied within the treatment field. This is done by dividing a large beam into many small beamlets. Dose constraints are assigned to both the target and sensitive structures and computerised inverse optimization is performed to find the individual weights of this large number of beamlets. The computer adjusts the intensities of these beamlets according to the required planning dose objectives. The optimized intensity patterns are then decomposed into a series of deliverable multi leaf collimator (MLC) shapes in the sequencing step. One of the main problems of IMRT, which becomes even more apparent as the complexity of the IMRT plan increases, is the dramatic increase in the number of Monitor Units (MU) required to deliver a fractionated treatment. The difficulty with this increase in MU is its association with increased treatment times and a greater leakage of radiation from the MLCs increasing the total body dose and the risk of secondary cancers in patients. Therefore one attempts to find ways of reducing these MU without compromising plan quality. The design of inverse planning systems where the beam is divided into small beamlets to produce the required intensity map automatically introduces complexity into IMRT treatment planning. Plan complexity is associated with many negative factors such as dosimetric uncertainty and delivery issues A large search space is required necessitating much computing power. However, the limitations of the delivery technology are not taken into consideration when designing the ideal intensity map therefore a further step termed the sequencing step is required to convert the ideal intensity map into a deliverable one. Many approaches have been taken to reduce the complexity. These include setting intensity limits, putting penalties on the cost function and using smoothing filters Direct Aperture optimization

  6. Osteoradionecrosis of the mandible. Minimized risk profile following Intensity-Modulated Radiation Therapy (IMRT)

    Energy Technology Data Exchange (ETDEWEB)

    Studer, G.; Huguenin, P.; Luetolf, U.M.; Glanzmann, C. [Dept. of Radiation Oncology, Univ. Hospital, Zurich (Switzerland); Studer, S.P.; Zwahlen, R.A.; Graetz, K.W. [Dept. of Craniomaxillofacial Surgery, Univ. Hospital, Zurich (Switzerland)

    2006-05-15

    Background and purpose: osteoradionecrosis (ON) of the mandible is a serious late complication of high-dose radiation therapy for tumors of the oropharynx and oral cavity. After doses between 60 and 72 Gy using standard fractionation, an incidence of ON between 5% and 15% is reported in a review from 1989, whereas in more recent publications using moderately accelerated or hyperfractionated irradiation and doses between 69 and 81 Gy, the incidence of ON is between < 1% and {proportional_to} 6%. Intensity-modulated radiation therapy (IMRT) is expected to translate into a further important reduction of ON. The aim of this descriptive study was to assess absolute and relative bone volumes exposed to high IMRT doses, related to observed bone tolerance. Patients and methods: between December 2001 and November 2004, 73 of 123 patients treated with IMRT were identified as subgroup ''at risk'' for ON (> 60 Gy for oropharyngeal or oral cavity cancer). 21/73 patients were treated in a postoperative setting, 52 patients underwent primary definitive irradiation. In 56 patients concomitant cisplatin-based chemotherapy was applied. Mean follow-up time was 22 months (12-46 months). Oral cavity including the mandible bone outside the planning target volume was contoured and dose-volume constraints were defined in order to spare bone tissue. Dose-volume histograms were obtained from contoured mandible in each patient and were analyzed and related to clinical mandible bone tolerance. Results: using IMRT with doses between 60 and 75 Gy (mean 67 Gy), on average 7.8, 4.8, 0.9, and 0.3 cm{sup 3} were exposed to doses > 60, 65, 70, and 75 Gy, respectively. These values are substantially lower than when using three-dimensional conformal radiotherapy. The difference has been approximately quantified by comparison with a historic series. Additional ON risk factors of the patients were also analyzed. Only one grade 3 ON of the lingual horizontal branch, treated with

  7. Predictors of Dysgeusia in Patients With Oropharyngeal Cancer Treated With Chemotherapy and Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sapir, Eli [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Tao, Yebin [Department of Biostatistics, University of Michigan, Ann Arbor, Michigan (United States); Feng, Felix; Samuels, Stuart; El Naqa, Issam [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Murdoch-Kinch, Carol A. [School of Dentistry, University of Michigan, Ann Arbor, Michigan (United States); Feng, Mary [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Schipper, Matthew [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Department of Biostatistics, University of Michigan, Ann Arbor, Michigan (United States); Eisbruch, Avraham, E-mail: eisbruch@umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2016-10-01

    Objective(s): Dysgeusia is a significant factor reducing quality of life and worsening dysphagia in patients receiving chemoradiation therapy for head and neck cancer. The factors affecting dysgeusia severity are uncertain. We investigated the effects on patient-reported dysgeusia of doses to the oral cavity, salivary output (required to dissolve food particles), and patient-reported xerostomia. Methods and Materials: Seventy-three patients with stage III to IV oropharyngeal cancer (OPC) (N=73) receiving definitive intensity modulated radiation therapy concurrently with chemotherapy participated in a prospective, longitudinal study of quality of life (QOL), including assessment of patient-reported gustatory function by taste-related questions from the Head and Neck QOL instrument (HNQOL) and the University of Washington Head and Neck-related QOL instrument (UWQOL), before therapy and periodically after treatment. At these intervals, patients also completed a validated xerostomia-specific questionnaire (XQ) and underwent unstimulated and stimulated major salivary gland flow rate measurements. Results: At 1, 3, 6, and 12 months after treatment, dysgeusia improved over time: severe dysgeusia was reported by 50%, 40%, 22%, and 23% of patients, respectively. Significant associations were found between patient-reported severe dysgeusia and radiation dose to the oral cavity (P=.005) and tongue (P=.019); normal tissue complication probability for severe dysgeusia at 3 months showed mean oral cavity D{sub 50} doses 53 Gy and 57 Gy in the HNQOL and WUQOL questionnaires, respectively, with curve slope (m) of 0.41. Measured salivary output was not statistically significantly correlated with severe taste dysfunction, whereas patient-reported XQ summary scores and xerostomia while eating scores were correlated with severe dysgeusia in the UWQOL tool (P=.04). Conclusions: Taste impairment is significantly correlated with mean radiation dose to the oral cavity. Patient

  8. Application of intensity modulated radiation therapy for the cancer patients treatment in Bach Mai Hospital

    International Nuclear Information System (INIS)

    Mai Trong Khoa; Tran Dinh Ha; Le Chinh Dai; Nguyen Quang Hung; Vu Huu Khiem

    2011-01-01

    Intensity modulated radiotherapy (IMRT) is one of the modern techniques in cancer treatment, in which dose is delivered optimally into the shape of the tumor and minimally in surround benign tissues. In developed countries, this technique has been performed routinely by Linacs with MLC for tumors at the critical areas. In Vietnam, because of the wet climate, the use of Linacs with MLC is difficult to operate and maintain. However, IMRT can be implemented by Linacs without MLC via independent jaws, Jaws-only IMRT (JO-IMRT), in which beams are separated into many segments with different weights to optimize highest dose in the tumor and lowest dose in the surrounding health organs. Methods: We describe the new treatment technic application and compare it with normal radiotherapy method (3D-CRT). Results: From 7/2008, the Dep of Nuclear Medicine and Oncology at Bach Mai Hospital has been conducting JO-IMRT to treat cancer patients. Up to now, we have 81 cases treated by IMRT including head and neck cancers (NPC, larynx cancer, maxillary sinus cancer, brain tumor), cancers in the thorax (esophagus cancer, lung cancer, breast cancer), cancers in the pelvis (prostate cancer, cervical cancer, rectal cancer). On the average, beam number is from 5 to 9 and 5-9 segments per beam. Treatment time for a fraction is from 6 to 12 minutes with 2.25 Gy for CTV1 per day. Discrepancies of doses were below 3% (0.15 to 2.84%) between planning and practice. In plan, the preeminences with IMRT are clearly superior to 3D radiation therapy. In clinical, almost patients had good respond, whereas side effects were quite less than conventional radiotherapy. Conclusions: JO-IMRT is a modern technic with more advantage than normal 3D-CRT. It help radiation dose to concentrate maximally in treatment target while influence minimally for sensitive surrounding tissues. Another, it is a high technic to appropriate with the climatic condition in Vietnam. (author)

  9. Treatment of Oral Cavity Squamous Cell Carcinoma With Adjuvant or Definitive Intensity-Modulated Radiation Therapy

    International Nuclear Information System (INIS)

    Sher, David J.; Thotakura, Vijaya; Balboni, Tracy A.; Norris, Charles M.; Haddad, Robert I.; Posner, Marshall R.; Lorch, Jochen; Goguen, Laura A.; Annino, Donald J.; Tishler, Roy B.

    2011-01-01

    Purpose: The optimal management of oral cavity squamous cell carcinoma (OCSCC) typically involves surgical resection followed by adjuvant radiotherapy or chemoradiotherapy (CRT) in the setting of adverse pathologic features. Intensity-modulated radiation therapy (IMRT) is frequently used to treat oral cavity cancers, but published IMRT outcomes specific to this disease site are sparse. We report the Dana-Farber Cancer Institute experience with IMRT-based treatment for OCSCC. Methods and Materials: Retrospective study of all patients treated at Dana-Farber Cancer Institute for OCSCC with adjuvant or definitive IMRT between August 2004 and December 2009. The American Joint Committee on Cancer disease stage criteria distribution of this cohort included 5 patients (12%) with stage I; 10 patients (24%) with stage II (n = 10, 24%),; 14 patients (33%) with stage III (n = 14, 33%),; and 13 patients (31%) with stage IV. The primary endpoint was overall survival (OS); secondary endpoints were locoregional control (LRC) and acute and chronic toxicity. Results: Forty-two patients with OCSCC were included, 30 of whom were initially treated with surgical resection. Twenty-three (77%) of 30 surgical patients treated with adjuvant IMRT also received concurrent chemotherapy, and 9 of 12 (75%) patients treated definitively without surgery were treated with CRT or induction chemotherapy and CRT. With a median follow-up of 2.1 years (interquartile range, 1.1–3.1 years) for all patients, the 2-year actuarial rates of OS and LRC following adjuvant IMRT were 85% and 91%, respectively, and the comparable results for definitive IMRT were 63% and 64% for OS and LRC, respectively. Only 1 patient developed symptomatic osteoradionecrosis, and among patients without evidence of disease, 35% experienced grade 2 to 3 late dysphagia, with only 1 patient who was continuously gastrostomy-dependent. Conclusions: In this single-institution series, postoperative IMRT was associated with promising LRC

  10. Examination of geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Wiersma, R. D.; Xing, L.

    2007-01-01

    Due to the complicated technical nature of gated radiation therapy, electronic and mechanical limitations may affect the precision of delivery. The purpose of this study is to investigate the geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation treatments (SS-IMRT). Unique segmental MLC plans are designed, which allow quantitative testing of the gating process. Both ungated and gated deliveries are investigated for different dose sizes, dose rates, and gating window times using a commercial treatment system (Varian Trilogy) together with a respiratory gating system [Varian Real-Time Position Management system]. Radiographic film measurements are used to study the geometric accuracy, where it is found that with both ungated and gated SS-IMRT deliveries the MLC leaf divergence away from planned is less than or equal to the MLC specified leaf tolerance value for all leafs (leaf tolerance being settable from 0.5-5 mm). Nevertheless, due to the MLC controller design, failure to define a specific leaf tolerance value suitable to the SS-IMRT plan can lead to undesired geometric effects, such as leaf motion of up to the maximum 5 mm leaf tolerance value occurring after the beam is turned on. In this case, gating may be advantageous over the ungated case, as it allows more time for the MLC to reach the intended leaf configuration. The dosimetric precision of gated SS-IMRT is investigated using ionization chamber methods. Compared with the ungated case, it is found that gating generally leads to increased dosimetric errors due to the interruption of the ''overshoot phenomena.'' With gating the average timing deviation for intermediate segments is found to be 27 ms, compared to 18 ms for the ungated case. For a plan delivered at 600 MU/min this would correspond to an average segment dose error of ∼0.27 MU and ∼0.18 MU for gated and ungated deliveries, respectively. The maximum dosimetric errors for individual intermediate segments are

  11. Treatment of Oral Cavity Squamous Cell Carcinoma With Adjuvant or Definitive Intensity-Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sher, David J., E-mail: dsher@lroc.harvard.edu [Department of Radiation Oncology, Dana-Farber Cancer Institute and Brigham and Women' s Hospital, Boston, Massachusetts (United States); Thotakura, Vijaya [Department of Medical Oncology, Dana-Farber Cancer Institute and Department of Medicine, Brigham and Women' s Hospital, Boston, Massachusetts (United States); Balboni, Tracy A. [Department of Radiation Oncology, Dana-Farber Cancer Institute and Brigham and Women' s Hospital, Boston, Massachusetts (United States); Norris, Charles M.; Haddad, Robert I.; Posner, Marshall R.; Lorch, Jochen [Department of Medical Oncology, Dana-Farber Cancer Institute and Department of Medicine, Brigham and Women' s Hospital, Boston, Massachusetts (United States); Goguen, Laura A.; Annino, Donald J. [Department of Surgery, Division of Otolaryngology, Brigham and Women' s Hospital, Boston, Massachusetts (United States); Tishler, Roy B. [Department of Radiation Oncology, Dana-Farber Cancer Institute and Brigham and Women' s Hospital, Boston, Massachusetts (United States)

    2011-11-15

    Purpose: The optimal management of oral cavity squamous cell carcinoma (OCSCC) typically involves surgical resection followed by adjuvant radiotherapy or chemoradiotherapy (CRT) in the setting of adverse pathologic features. Intensity-modulated radiation therapy (IMRT) is frequently used to treat oral cavity cancers, but published IMRT outcomes specific to this disease site are sparse. We report the Dana-Farber Cancer Institute experience with IMRT-based treatment for OCSCC. Methods and Materials: Retrospective study of all patients treated at Dana-Farber Cancer Institute for OCSCC with adjuvant or definitive IMRT between August 2004 and December 2009. The American Joint Committee on Cancer disease stage criteria distribution of this cohort included 5 patients (12%) with stage I; 10 patients (24%) with stage II (n = 10, 24%),; 14 patients (33%) with stage III (n = 14, 33%),; and 13 patients (31%) with stage IV. The primary endpoint was overall survival (OS); secondary endpoints were locoregional control (LRC) and acute and chronic toxicity. Results: Forty-two patients with OCSCC were included, 30 of whom were initially treated with surgical resection. Twenty-three (77%) of 30 surgical patients treated with adjuvant IMRT also received concurrent chemotherapy, and 9 of 12 (75%) patients treated definitively without surgery were treated with CRT or induction chemotherapy and CRT. With a median follow-up of 2.1 years (interquartile range, 1.1-3.1 years) for all patients, the 2-year actuarial rates of OS and LRC following adjuvant IMRT were 85% and 91%, respectively, and the comparable results for definitive IMRT were 63% and 64% for OS and LRC, respectively. Only 1 patient developed symptomatic osteoradionecrosis, and among patients without evidence of disease, 35% experienced grade 2 to 3 late dysphagia, with only 1 patient who was continuously gastrostomy-dependent. Conclusions: In this single-institution series, postoperative IMRT was associated with promising LRC

  12. Intensity Modulated Proton Beam Radiation for Brachytherapy in Patients With Cervical Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Clivio, Alessandro [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland); Kluge, Anne [Department of Radiation Oncology, Charité University Hospital, Berlin (Germany); Cozzi, Luca, E-mail: lucozzi@iosi.ch [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland); Köhler, Christhardt [Department of Gynecology, Charité University Hospital, Berlin (Germany); Neumann, Oliver [Department of Radiation Oncology, Charité University Hospital, Berlin (Germany); Vanetti, Eugenio [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland); Wlodarczyk, Waldemar; Marnitz, Simone [Department of Radiation Oncology, Charité University Hospital, Berlin (Germany)

    2013-12-01

    Purpose: To evaluate intensity modulated proton therapy (IMPT) in patients with cervical cancer in terms of coverage, conformity, and dose–volume histogram (DVH) parameters correlated with recommendations from magnetic resonance imaging (MRI)-guided brachytherapy. Methods and Materials: Eleven patients with histologically proven cervical cancer underwent primary chemoradiation for the pelvic lymph nodes, the uterus, the cervix, and the parametric region, with a symmetric margin of 1 cm. The prescription was for 50.4 Gy, with 1.8 Gy per fraction. The prescribed dose to the parametria was 2.12 Gy up to 59.36 Gy in 28 fractions as a simultaneous boost. For several reasons, the patients were unable to undergo brachytherapy. As an alternative, IMPT was planned with 5 fractions of 6 Gy to the cervix, including the macroscopic tumor with an MRI-guided target definition, with an isotropic margin of 5 mm for planning target volume (PTV) definition. Groupe-Europeen de Curietherapie and European society for Radiotherapy and Oncology (GEC-ESTRO) criteria were used for DVH evaluation. Reference comparison plans were optimized for volumetric modulated rapid arc (VMAT) therapy with the RapidArc (RA). Results: The dose to the high-risk volume was calculated with α/β = 10 with 89.6 Gy. For IMPT, the clinical target volume showed a mean dose of 38.2 ± 5.0 Gy (35.0 ±1.8 Gy for RA). The D{sub 98%} was 31.9 ± 2.6 Gy (RA: 30.8 ± 1.0 Gy). With regard to the organs at risk, the 2Gy Equivalent Dose (EQD2) (α/β = 3) to 2 cm{sup 3} of the rectal wall, sigmoid wall, and bladder wall was 62.2 ± 6.4 Gy, 57.8 ± 6.1 Gy, and 80.6 ± 8.7 Gy (for RA: 75.3 ± 6.1 Gy, 66.9 ± 6.9 Gy, and 89.0 ± 7.2 Gy, respectively). For the IMPT boost plans in combination with external beam radiation therapy, all DVH parameters correlated with <5% risk for grades 2 to 4 late gastrointestinal and genitourinary toxicity. Conclusion: In patients who are not eligible for brachytherapy, IMPT as a boost

  13. Evaluation of intra- and inter-fraction movement of the cervix during intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Haripotepornkul, Nora H.; Nath, Sameer K.; Scanderbeg, Daniel; Saenz, Cheryl; Yashar, Catheryn M.

    2011-01-01

    Background and purpose: To assess the degree of intra- and inter-fraction cervical motion throughout a course of intensity modulated radiation therapy (IMRT) for cervical cancer patients. Materials and methods: A retrospective study of 10 women with stage 1B1-3B cervical cancer diagnosed from September 2007 to July 2008 was conducted. All patients were treated with chemoradiation using IMRT followed by intracavitary brachytherapy. Pretreatment, patients had 2 seeds placed at a depth of 10 mm into the cervix. On-Board Imaging (OBI) was used to obtain anterior/posterior (AP) and lateral X-rays before and after each treatment. OBI images were rigidly aligned to baseline digitally reconstructed radiographs (DRRs), and movement of cervical seeds was determined in the lateral, vertical, and AP directions. Mean differences in cervical seed position and standard error of the mean (SEM) were calculated. Results: A total of 922 images were reviewed, with approximately 90 images per patient. The mean intra-fractional movement in cervical seed position in the lateral, vertical, and AP directions were 1.6 mm (SD ± 2.0), 2.6 mm (SD ± 2.4), and 2.9 mm (SD ± 2.7), respectively, with a range from 0 to 15 mm for each direction. The mean inter-fractional movement in the lateral, vertical, and AP directions were 1.9 mm (SD ± 1.9), 4.1 mm (SD ± 3.2), and 4.2 mm (SD ± 3.5), respectively, with a range from 0 to 18 mm for each direction. Conclusions: This is the first study to assess intra- and inter-fractional movement of the cervix using daily imaging before and after each fraction. Within and between radiation treatments, cervical motion averages approximately 3 mm in any given direction. However, maximal movement of the cervix can be as far as 18 mm from baseline. This wide range of motion needs to be accounted for when generating planning treatment volumes.

  14. Factors influencing the incidence of sinusitis in nasopharyngeal carcinoma patients after intensity-modulated radiation therapy.

    Science.gov (United States)

    Su, Yan-xia; Liu, Lan-ping; Li, Lei; Li, Xu; Cao, Xiu-juan; Dong, Wei; Yang, Xin-hua; Xu, Jin; Yu, Shui; Hao, Jun-fang

    2014-12-01

    The aim of the study was to investigate the incidence of sinusitis in nasopharyngeal carcinoma (NPC) patients before and after intensity-modulated radiation therapy (IMRT) and to analyze factors associated with the incidence of sinusitis following IMRT. We retrospectively analyzed 283 NPC patients who received IMRT in our hospital from March 2009 to May 2011. The diagnostic criteria for sinusitis are based on computed tomography (CT) or magnetic resonance imaging (MRI) findings. CT or MRI scans were performed before and after IMRT to evaluate the incidence of sinusitis. Factors influencing the incidence of sinusitis were analyzed by log-rank univariate and logistic multivariate analyses. Among the 283 NPC patients, 128 (45.2 %) suffered from sinusitis before radiotherapy. The incidence rates of sinusitis in patients with T1, T2, T3, and T4 NPC before radiotherapy were 22.6, 37.5, 46.8, and 61.3 %, respectively (χ 2 = 14.548, p = 0.002). Among the 155 NPC patients without sinusitis before radiotherapy, the incidence rates of sinusitis at the end of radiotherapy and at 1, 3, 6, 9, 12, and 18 months after radiotherapy were 32.9, 43.2, 61.3, 68.4, 73.5, 69.7, and 61.3 %, respectively (χ 2 = 86.461, p < 0.001). Univariate analysis showed that T stage, invasion of the nasal cavity, nasal irrigation, and radiation dose to the nasopharynx were associated with the incidence of sinusitis in NPC patients after IMRT (p = 0.003, 0.006, 0.002, and 0.020). Multivariate analysis showed that T stage, invasion of the nasal cavity, and nasal irrigation were influential factors for the incidence of sinusitis in NPC patients after IMRT (p = 0.002, 0.002, and 0.000). There was a higher incidence of sinusitis with higher T stage among NPC patients before radiotherapy, and the incidence of sinusitis in NPC patients after IMRT was high (45.2 %). The incidence of sinusitis increased rapidly within the first 3 months after IMRT, and the number of sinusitis cases peaked at 6-9 months after

  15. Predictive factors for acute radiation pneumonitis in postoperative intensity modulated radiation therapy and volumetric modulated arc therapy of esophageal cancer.

    Science.gov (United States)

    Zhao, Yaqin; Chen, Lu; Zhang, Shu; Wu, Qiang; Jiang, Xiaoqin; Zhu, Hong; Wang, Jin; Li, Zhiping; Xu, Yong; Zhang, Ying Jie; Bai, Sen; Xu, Feng

    2015-01-01

    Radiation pneumonitis (RP) is a common side reaction in radiotherapy for esophageal cancer. There are few reports about RP in esophageal cancer patients receiving postoperative intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). This study aims to analyze clinical or dosimetric factors associated with RP, and provides data for radiotherapy planning. We reviewed 68 postoperative esophageal cancer patients who were treated with radiotherapy at the West China Hospital from October 2010 to November 2012 to identify any correlation between the clinical or dosimetric parameters and acute radiation pneumonitis (ARP) or severe acute radiation pneumonitis (SARP) by t-test, chi-square test, and logistic regression analysis. Of the 68 patients, 33 patients (48.5%) developed ARP, 13 of which (19.1%) developed SARP. Of these 33 patients, 8 (11.8%), 12 (17.6%), 11 (16.2%), and 2 (2.9%) patients were grade 1, 2, 3, and 4 ARP, respectively. Univariate analysis showed that lung infection during radiotherapy, use of VMAT, mean lung dose (MLD), and dosimetric parameters (e.g. V20, V30) are significantly correlated with RP. Multivariate analysis found that lung infection during radiotherapy, MLD ≥ 12 Gy, and V30 ≥ 13% are significantly correlated with an increased risk of RP. Lung infection during radiotherapy and low radiation dose volume distribution were predictive factors associated with RP and should be accounted for during radiation planning.

  16. State of the art on dose prescription, reporting and recording in Intensity-Modulated Radiation Therapy (ICRU report No. 83)

    International Nuclear Information System (INIS)

    Gregoire, V.; Mackie, T.R.

    2011-01-01

    The International Commission on Radiation Units and Measurements (ICRU) report No. 83 provides the information necessary to standardize techniques and procedures and to harmonize the prescribing, recording, and reporting of intensity modulated radiation therapy. Applicable concepts and recommendations in previous ICRU reports concerning radiation therapy were adopted, and new concepts were elaborated. In particular, additional recommendations were given on the selection and delineation of the targets volumes and the organs at risk; concepts of dose prescription and dose-volume reporting have also been refined. (authors)

  17. Carcinoma of the anal canal: Intensity modulated radiation therapy (IMRT) versus three-dimensional conformal radiation therapy (3DCRT)

    International Nuclear Information System (INIS)

    Sale, Charlotte; Moloney, Phillip; Mathlum, Maitham

    2013-01-01

    Patients with anal canal carcinoma treated with standard conformal radiotherapy frequently experience severe acute and late toxicity reactions to the treatment area. Roohipour et al. (Dis Colon Rectum 2008; 51: 147–53) stated a patient's tolerance of chemoradiation to be an important prediction of treatment success. A new intensity modulated radiation therapy (IMRT) technique for anal carcinoma cases has been developed at the Andrew Love Cancer Centre aimed at reducing radiation to surrounding healthy tissue. A same-subject repeated measures design was used for this study, where five anal carcinoma cases at the Andrew Love Cancer Centre were selected. Conformal and IMRT plans were generated and dosimetric evaluations were performed. Each plan was prescribed a total of 54 Gray (Gy) over a course of 30 fractions to the primary site. The IMRT plans resulted in improved dosimetry to the planning target volume (PTV) and reduction in radiation to the critical structures (bladder, external genitalia and femoral heads). Statistically there was no difference between the IMRT and conformal plans in the dose to the small and large bowel; however, the bowel IMRT dose–volume histogram (DVH) doses were consistently lower. The IMRT plans were superior to the conformal plans with improved dose conformity and reduced radiation to the surrounding healthy tissue. Anecdotally it was found that patients tolerated the IMRT treatment better than the three-dimensional (3D) conformal radiation therapy. This study describes and compares the planning techniques

  18. Analysis of late toxicity in nasopharyngeal carcinoma patients treated with intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Zheng, YingJie; Han, Fei; Xiao, WeiWei; Xiang, YanQun; Lu, LiXia; Deng, XiaoWu; Cui, NianJi; Zhao, Chong

    2015-01-01

    To observe the late toxicities in nasopharyngeal carcinoma (NPC) patients who achieved long-term survival after intensity modulated radiation therapy (IMRT). 208 untreated NPC patients who received IMRT and survived more than five years with locoregional disease control and no metastasis were evaluated in this study. The prescription dose to the gross target volume of nasopharynx (GTVnx), positive neck lymph nodes (GTVnd), clinical target volume 1 (CTV1) and 2 (CTV2) was 68Gy/30f, 60-66Gy/30f, 60 Gy/30f and 54Gy/30f, respectively. The nasopharynx and upper neck targets were irradiated using IMRT, and the lower neck and supraclavicular fossae targets were irradiated using the half-beam technique with conventional irradiation. The late toxicities were evaluated according to the LENT/SOMA criteria of 1995. The median follow-up time was 78 months (60–96 months). The occurrence rates of cervical subcutaneous fibrosis, hearing loss, skin dystrophy, xerostomia, trismus, temporal lobe injury, cranial nerve damage, cataract, and brain stem injury induced by radiotherapy were 89.9%, 67.8%, 47.6%, 40.9%, 7.21%, 4.33%, 2.88%, 1.44%, and 0.48%, respectively. No spinal cord injury and mandible damage were found. Grade 3–4 late injuries were observed as follows: 1 (0.48%) skin dystrophy, 4 (1.92%) cervical subcutaneous fibrosis, 2 (0.96%) hearing loss, 2 (0.96%) cranial nerve palsy, and 1 (0.48%) temporal lobe necrosis. No grade 3–4 late injuries occurred in parotid, temporomandibular joints and eyes. Xerostomia decreased gradually over time and then showed only slight changes after 4 years. The change in the incisor distance stabilised by 1 year after RT, however, the incidence of hearing loss, skin dystrophy, subcutaneous fibrosis and nervous system injuries increased over time after RT. The late injuries in most NPC patients who had long-term survivals after IMRT are alleviated. Within the 5 years of follow-up, we found xerostomia decreased gradually; The change in the

  19. Beyond bixels: Generalizing the optimization parameters for intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Markman, Jerry; Low, Daniel A.; Beavis, Andrew W.; Deasy, Joseph O.

    2002-01-01

    Intensity modulated radiation therapy (IMRT) treatment planning systems optimize fluence distributions by subdividing the fluence distribution into rectangular bixels. The algorithms typically optimize the fluence intensity directly, often leading to fluence distributions with sharp discontinuities. These discontinuities may yield difficulties in delivery of the fluence distribution, leading to inaccurate dose delivery. We have developed a method for decoupling the bixel intensities from the optimization parameters; either by introducing optimization control points from which the bixel intensities are interpolated or by parametrizing the fluence distribution using basis functions. In either case, the number of optimization search parameters is reduced from the direct bixel optimization method. To illustrate the concept, the technique is applied to two-dimensional idealized head and neck treatment plans. The interpolation algorithms investigated were nearest-neighbor, linear and cubic spline, and radial basis functions serve as the basis function test. The interpolation and basis function optimization techniques were compared against the direct bixel calculation. The number of optimization parameters were significantly reduced relative to the bixel optimization, and this was evident in the reduction of computation time of as much as 58% from the full bixel optimization. The dose distributions obtained using the reduced optimization parameter sets were very similar to the full bixel optimization when examined by dose distributions, statistics, and dose-volume histograms. To evaluate the sensitivity of the fluence calculations to spatial misalignment caused either by delivery errors or patient motion, the doses were recomputed with a 1 mm shift in each beam and compared to the unshifted distributions. Except for the nearest-neighbor algorithm, the reduced optimization parameter dose distributions were generally less sensitive to spatial shifts than the bixel

  20. Origin of Tumor Recurrence After Intensity Modulated Radiation Therapy for Oropharyngeal Squamous Cell Carcinoma

    International Nuclear Information System (INIS)

    Raktoe, Sawan A.S.; Dehnad, Homan; Raaijmakers, Cornelis P.J.; Braunius, Weibel; Terhaard, Chris H.J.

    2013-01-01

    Purpose: To model locoregional recurrences of oropharyngeal squamous cell carcinomas (OSCC) treated with primary intensity modulated radiation therapy (IMRT) in order to find the origins from which recurrences grow and relate their location to original target volume borders. Methods and Materials: This was a retrospective analysis of OSCC treated with primary IMRT between January 2002 and December 2009. Locoregional recurrence volumes were delineated on diagnostic scans and coregistered rigidly with treatment planning computed tomography scans. Each recurrence was analyzed with two methods. First, overlapping volumes of a recurrence and original target were measured (‘volumetric approach’) and assessed as ‘in-field’, ‘marginal’, or ‘out-field’. Then, the center of mass (COM) of a recurrence volume was assumed as the origin from where a recurrence expanded, the COM location was compared with original target volume borders and assessed as ‘in-field’, ‘marginal’, or ‘out-field’. Results: One hundred thirty-one OSCC were assessed. For all patients alive at the end of follow-up, the mean follow-up time was 40 months (range, 12-83 months); 2 patients were lost to follow-up. The locoregional recurrence rate was 27%. Of all recurrences, 51% were local, 23% were regional, and 26% had both local and regional recurrences. Of all recurrences, 74% had imaging available for assessment. Regarding volumetric analysis of local recurrences, 15% were in-field gross tumor volume (GTV), and 65% were in-field clinical tumor volume (CTV). Using the COM approach, we found that 70% of local recurrences were in-field GTV and 90% were in-field CTV. Of the regional recurrences, 25% were volumetrically in-field GTV, and using the COM approach, we found 54% were in-field GTV. The COM of local out-field CTV recurrences were maximally 16 mm outside CTV borders, whereas for regional recurrences, this was 17 mm. Conclusions: The COM model is practical and specific for

  1. Origin of Tumor Recurrence After Intensity Modulated Radiation Therapy for Oropharyngeal Squamous Cell Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Raktoe, Sawan A.S. [Department of Radiotherapy, University Medical Center Utrecht, Utrecht (Netherlands); Dehnad, Homan, E-mail: h.dehnad@umcutrecht.nl [Department of Radiotherapy, University Medical Center Utrecht, Utrecht (Netherlands); Raaijmakers, Cornelis P.J. [Department of Radiotherapy, University Medical Center Utrecht, Utrecht (Netherlands); Braunius, Weibel [Department of ENT Head and Neck Surgery, University Medical Center Utrecht, Utrecht (Netherlands); Terhaard, Chris H.J. [Department of Radiotherapy, University Medical Center Utrecht, Utrecht (Netherlands)

    2013-01-01

    Purpose: To model locoregional recurrences of oropharyngeal squamous cell carcinomas (OSCC) treated with primary intensity modulated radiation therapy (IMRT) in order to find the origins from which recurrences grow and relate their location to original target volume borders. Methods and Materials: This was a retrospective analysis of OSCC treated with primary IMRT between January 2002 and December 2009. Locoregional recurrence volumes were delineated on diagnostic scans and coregistered rigidly with treatment planning computed tomography scans. Each recurrence was analyzed with two methods. First, overlapping volumes of a recurrence and original target were measured ('volumetric approach') and assessed as 'in-field', 'marginal', or 'out-field'. Then, the center of mass (COM) of a recurrence volume was assumed as the origin from where a recurrence expanded, the COM location was compared with original target volume borders and assessed as 'in-field', 'marginal', or 'out-field'. Results: One hundred thirty-one OSCC were assessed. For all patients alive at the end of follow-up, the mean follow-up time was 40 months (range, 12-83 months); 2 patients were lost to follow-up. The locoregional recurrence rate was 27%. Of all recurrences, 51% were local, 23% were regional, and 26% had both local and regional recurrences. Of all recurrences, 74% had imaging available for assessment. Regarding volumetric analysis of local recurrences, 15% were in-field gross tumor volume (GTV), and 65% were in-field clinical tumor volume (CTV). Using the COM approach, we found that 70% of local recurrences were in-field GTV and 90% were in-field CTV. Of the regional recurrences, 25% were volumetrically in-field GTV, and using the COM approach, we found 54% were in-field GTV. The COM of local out-field CTV recurrences were maximally 16 mm outside CTV borders, whereas for regional recurrences, this was 17 mm. Conclusions: The

  2. A new Monte Carlo-based treatment plan optimization approach for intensity modulated radiation therapy.

    Science.gov (United States)

    Li, Yongbao; Tian, Zhen; Shi, Feng; Song, Ting; Wu, Zhaoxia; Liu, Yaqiang; Jiang, Steve; Jia, Xun

    2015-04-07

    Intensity-modulated radiation treatment (IMRT) plan optimization needs beamlet dose distributions. Pencil-beam or superposition/convolution type algorithms are typically used because of their high computational speed. However, inaccurate beamlet dose distributions may mislead the optimization process and hinder the resulting plan quality. To solve this problem, the Monte Carlo (MC) simulation method has been used to compute all beamlet doses prior to the optimization step. The conventional approach samples the same number of particles from each beamlet. Yet this is not the optimal use of MC in this problem. In fact, there are beamlets that have very small intensities after solving the plan optimization problem. For those beamlets, it may be possible to use fewer particles in dose calculations to increase efficiency. Based on this idea, we have developed a new MC-based IMRT plan optimization framework that iteratively performs MC dose calculation and plan optimization. At each dose calculation step, the particle numbers for beamlets were adjusted based on the beamlet intensities obtained through solving the plan optimization problem in the last iteration step. We modified a GPU-based MC dose engine to allow simultaneous computations of a large number of beamlet doses. To test the accuracy of our modified dose engine, we compared the dose from a broad beam and the summed beamlet doses in this beam in an inhomogeneous phantom. Agreement within 1% for the maximum difference and 0.55% for the average difference was observed. We then validated the proposed MC-based optimization schemes in one lung IMRT case. It was found that the conventional scheme required 10(6) particles from each beamlet to achieve an optimization result that was 3% difference in fluence map and 1% difference in dose from the ground truth. In contrast, the proposed scheme achieved the same level of accuracy with on average 1.2 × 10(5) particles per beamlet. Correspondingly, the computation

  3. Particle swarm optimizer for weighting factor selection in intensity-modulated radiation therapy optimization algorithms.

    Science.gov (United States)

    Yang, Jie; Zhang, Pengcheng; Zhang, Liyuan; Shu, Huazhong; Li, Baosheng; Gui, Zhiguo

    2017-01-01

    In inverse treatment planning of intensity-modulated radiation therapy (IMRT), the objective function is typically the sum of the weighted sub-scores, where the weights indicate the importance of the sub-scores. To obtain a high-quality treatment plan, the planner manually adjusts the objective weights using a trial-and-error procedure until an acceptable plan is reached. In this work, a new particle swarm optimization (PSO) method which can adjust the weighting factors automatically was investigated to overcome the requirement of manual adjustment, thereby reducing the workload of the human planner and contributing to the development of a fully automated planning process. The proposed optimization method consists of three steps. (i) First, a swarm of weighting factors (i.e., particles) is initialized randomly in the search space, where each particle corresponds to a global objective function. (ii) Then, a plan optimization solver is employed to obtain the optimal solution for each particle, and the values of the evaluation functions used to determine the particle's location and the population global location for the PSO are calculated based on these results. (iii) Next, the weighting factors are updated based on the particle's location and the population global location. Step (ii) is performed alternately with step (iii) until the termination condition is reached. In this method, the evaluation function is a combination of several key points on the dose volume histograms. Furthermore, a perturbation strategy - the crossover and mutation operator hybrid approach - is employed to enhance the population diversity, and two arguments are applied to the evaluation function to improve the flexibility of the algorithm. In this study, the proposed method was used to develop IMRT treatment plans involving five unequally spaced 6MV photon beams for 10 prostate cancer cases. The proposed optimization algorithm yielded high-quality plans for all of the cases, without human

  4. Failure patterns after hemithoracic pleural intensity modulated radiation therapy for malignant pleural mesothelioma.

    Science.gov (United States)

    Rimner, Andreas; Spratt, Daniel E; Zauderer, Marjorie G; Rosenzweig, Kenneth E; Wu, Abraham J; Foster, Amanda; Yorke, Ellen D; Adusumilli, Prasad; Rusch, Valerie W; Krug, Lee M

    2014-10-01

    We previously reported our technique for delivering intensity modulated radiation therapy (IMRT) to the entire pleura while attempting to spare the lung in patients with malignant pleural mesothelioma (MPM). Herein, we report a detailed pattern-of-failure analysis in patients with MPM who were unresectable or underwent pleurectomy/decortication (P/D), uniformly treated with hemithoracic pleural IMRT. Sixty-seven patients with MPM were treated with definitive or adjuvant hemithoracic pleural IMRT between November 2004 and May 2013. Pretreatment imaging, treatment plans, and posttreatment imaging were retrospectively reviewed to determine failure location(s). Failures were categorized as in-field (within the 90% isodose line), marginal (<90% and ≥50% isodose lines), out-of-field (outside the 50% isodose line), or distant. The median follow-up was 24 months from diagnosis and the median time to in-field local failure from the end of RT was 10 months. Forty-three in-field local failures (64%) were found with a 1- and 2-year actuarial failure rate of 56% and 74%, respectively. For patients who underwent P/D versus those who received a partial pleurectomy or were deemed unresectable, the median time to in-field local failure was 14 months versus 6 months, respectively, with 1- and 2-year actuarial in-field local failure rates of 43% and 60% versus 66% and 83%, respectively (P=.03). There were 13 marginal failures (19%). Five of the marginal failures (38%) were located within the costomediastinal recess. Marginal failures decreased with increasing institutional experience (P=.04). Twenty-five patients (37%) had out-of-field failures. Distant failures occurred in 32 patients (48%). After hemithoracic pleural IMRT, local failure remains the dominant form of failure pattern. Patients treated with adjuvant hemithoracic pleural IMRT after P/D experience a significantly longer time to local and distant failure than patients treated with definitive pleural IMRT. Increasing

  5. Optimisation of conformal radiation therapy by intensity modulation Cancer of the larynx and salivary gland function

    International Nuclear Information System (INIS)

    Braaksma, Mirjam M.J.; Wijers, Oda B.; Soernsen de Koste, John R. van; Est, Henrie van der; Schmitz, Paul I.M.; Nowak, Peter J.C.M.; Levendag, Peter C.

    2003-01-01

    Purpose: Prevention of damage to critical normal tissues is of paramount importance for the quality of life of patients irradiated for cancers in the head and neck. The purpose of this paper was to evaluate the parotid gland sparing 3D conformal radiation therapy technique (3DCRT) in a prospective study in node negative cancer of the larynx. Materials and methods: Twenty-six patients with node negative squamous cell cancer of the larynx were irradiated by a 3DCRT technique (class solution) to both sides of the neck (elective dose 46 Gy to levels II, III and IV) and primary tumour (70 Gy). Dose distributions of the major salivary glands were correlated with objective (stimulated whole saliva flow, WS) and subjective (questionnaire; visual analogue scale, VAS) salivary gland function. Apart from the clinically used 3DCRT technique, in order to optimise 3DCRT dose distributions, intensity modulated (IMRT) treatment plans were generated for the same patient population. Dose-volume histograms of 3DCRT and IMRT treatment plans were analysed and compared. Results: For the 26 patients irradiated with the 3DCRT class solution technique: VAS scores and questionnaires reached their nadir 3 months post-radiotherapy; WS reached its nadir 6 months post-radiotherapy. WS flow rates improved significantly, but never normalised; 2 years post-treatment WS measurements were 48% of the pre-treatment values. VAS scores deteriorated during ERT from 0 pre-treatment to 6.1 immediately post-treatment. Compared to pre-treatment, questionnaires were answered affirmative by increasing numbers of patients. For all patients, IMRT treatment plans resulted in a significant reduction of the dose delivered to the parotid glands compared to the 3DCRT-treatment technique. Conclusions: The class solution for the 3DCRT salivary gland sparing technique is inadequate for fully preserving salivary gland function, given the dose distributions (DVHs) as well as the subjective- and objective salivary gland

  6. Postoperative Intensity Modulated Radiation Therapy in High Risk Prostate Cancer: A Dosimetric Comparison

    International Nuclear Information System (INIS)

    Digesu, Cinzia; Cilla, Savino; De Gaetano, Andrea; Massaccesi, Mariangela; Macchia, Gabriella; Ippolito, Edy; Deodato, Francesco; Panunzi, Simona; Iapalucci, Chiara; Mattiucci, Gian Carlo; D'Angelo, Elisa; Padula, Gilbert D.A.; Valentini, Vincenzo; Cellini, Numa

    2011-01-01

    The aim of this study was to compare intensity-modulated radiation therapy (IMRT) with 3D conformal technique (3D-CRT), with respect to target coverage and irradiation of organs at risk for high dose postoperative radiotherapy (PORT) of the prostate fossa. 3D-CRT and IMRT treatment plans were compared with respect to dose to the rectum and bladder. The dosimetric comparison was carried out in 15 patients considering 2 different scenarios: (1) exclusive prostate fossa irradiation, and (2) pelvic node irradiation followed by a boost on the prostate fossa. In scenario (1), a 3D-CRT plan (box technique) and an IMRT plan were calculated and compared for each patient. In scenario (2), 3 treatment plans were calculated and compared for each patient: (a) 3D-CRT box technique for both pelvic (prophylactic nodal irradiation) and prostate fossa irradiation (3D-CRT only); (b) 3D-CRT box technique for pelvic irradiation followed by an IMRT boost to the prostatic fossa (hybrid 3D-CRT and IMRT); and (c) IMRT for both pelvic and prostate fossa irradiation (IMRT only). For exclusive prostate fossa irradiation, IMRT significantly reduced the dose to the rectum (lower Dmean, V50%, V75%, V90%, V100%, EUD, and NTCP) and the bladder (lower Dmean, V50%, V90%, EUD and NTCP). When prophylactic irradiation of the pelvis was also considered, plan C (IMRT only) performed better than plan B (hybrid 3D-CRT and IMRT) as respect to both rectum and bladder irradiation (reduction of Dmean, V50%, V75%, V90%, equivalent uniform dose [EUD], and normal tissue complication probability [NTCP]). Plan (b) (hybrid 3D-CRT and IMRT) performed better than plan (a) (3D-CRT only) with respect to dose to the rectum (lower Dmean, V75%, V90%, V100%, EUD, and NTCP) and the bladder (Dmean, EUD, and NTCP). Postoperative IMRT in prostate cancer significantly reduces rectum and bladder irradiation compared with 3D-CRT.

  7. Failure Patterns After Hemithoracic Pleural Intensity Modulated Radiation Therapy for Malignant Pleural Mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Rimner, Andreas, E-mail: rimnera@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Spratt, Daniel E. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Zauderer, Marjorie G. [Department of Medicine, Thoracic Oncology Service, Memorial Sloan-Kettering Cancer Center, Weill Cornell Medical College, New York, New York (United States); Rosenzweig, Kenneth E. [Department of Radiation Oncology, Mount Sinai Medical Center, New York, New York (United States); Wu, Abraham J.; Foster, Amanda [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Yorke, Ellen D. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Adusumilli, Prasad; Rusch, Valerie W. [Department of Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Krug, Lee M. [Department of Medicine, Thoracic Oncology Service, Memorial Sloan-Kettering Cancer Center, Weill Cornell Medical College, New York, New York (United States)

    2014-10-01

    Purpose: We previously reported our technique for delivering intensity modulated radiation therapy (IMRT) to the entire pleura while attempting to spare the lung in patients with malignant pleural mesothelioma (MPM). Herein, we report a detailed pattern-of-failure analysis in patients with MPM who were unresectable or underwent pleurectomy/decortication (P/D), uniformly treated with hemithoracic pleural IMRT. Methods and Materials: Sixty-seven patients with MPM were treated with definitive or adjuvant hemithoracic pleural IMRT between November 2004 and May 2013. Pretreatment imaging, treatment plans, and posttreatment imaging were retrospectively reviewed to determine failure location(s). Failures were categorized as in-field (within the 90% isodose line), marginal (<90% and ≥50% isodose lines), out-of-field (outside the 50% isodose line), or distant. Results: The median follow-up was 24 months from diagnosis and the median time to in-field local failure from the end of RT was 10 months. Forty-three in-field local failures (64%) were found with a 1- and 2-year actuarial failure rate of 56% and 74%, respectively. For patients who underwent P/D versus those who received a partial pleurectomy or were deemed unresectable, the median time to in-field local failure was 14 months versus 6 months, respectively, with 1- and 2-year actuarial in-field local failure rates of 43% and 60% versus 66% and 83%, respectively (P=.03). There were 13 marginal failures (19%). Five of the marginal failures (38%) were located within the costomediastinal recess. Marginal failures decreased with increasing institutional experience (P=.04). Twenty-five patients (37%) had out-of-field failures. Distant failures occurred in 32 patients (48%). Conclusions: After hemithoracic pleural IMRT, local failure remains the dominant form of failure pattern. Patients treated with adjuvant hemithoracic pleural IMRT after P/D experience a significantly longer time to local and distant failure than

  8. Comparing two strategies of dynamic intensity modulated radiation therapy (dIMRT with 3-dimensional conformal radiation therapy (3DCRT in the hypofractionated treatment of high-risk prostate cancer

    Directory of Open Access Journals (Sweden)

    Yartsev Slav

    2008-01-01

    Full Text Available Abstract Background To compare two strategies of dynamic intensity modulated radiation therapy (dIMRT with 3-dimensional conformal radiation therapy (3DCRT in the setting of hypofractionated high-risk prostate cancer treatment. Methods 3DCRT and dIMRT/Helical Tomotherapy(HT planning with 10 CT datasets was undertaken to deliver 68 Gy in 25 fractions (prostate and simultaneously delivering 45 Gy in 25 fractions (pelvic lymph node targets in a single phase. The paradigms of pelvic vessel targeting (iliac vessels with margin are used to target pelvic nodes and conformal normal tissue avoidance (treated soft tissues of the pelvis while limiting dose to identified pelvic critical structures were assessed compared to 3DCRT controls. Both dIMRT/HT and 3DCRT solutions were compared to each other using repeated measures ANOVA and post-hoc paired t-tests. Results When compared to conformal pelvic vessel targeting, conformal normal tissue avoidance delivered more homogenous PTV delivery (2/2 t-test comparisons; p dose, 1–3 Gy over 5/10 dose points; p Conclusion dIMRT/HT nodal and pelvic targeting is superior to 3DCRT in dose delivery and critical structure sparing in the setting of hypofractionation for high-risk prostate cancer. The pelvic targeting paradigm is a potential solution to deliver highly conformal pelvic radiation treatment in the setting of nodal location uncertainty in prostate cancer and other pelvic malignancies.

  9. In vitro study of cell survival following dynamic MLC intensity-modulated radiation therapy dose delivery

    International Nuclear Information System (INIS)

    Moiseenko, Vitali; Duzenli, Cheryl; Durand, Ralph E.

    2007-01-01

    The possibility of reduced cell kill following intensity-modulated radiation therapy (IMRT) compared to conventional radiation therapy has been debated in the literature. This potential reduction in cell kill relates to prolonged treatment times typical of IMRT dose delivery and consequently increased repair of sublethal lesions. While there is some theoretical support to this reduction in cell kill published in the literature, direct experimental evidence specific to IMRT dose delivery patterns is lacking. In this study we present cell survival data for three cell lines: Chinese hamster V79 fibroblasts, human cervical carcinoma, SiHa and colon adenocarcinoma, WiDr. Cell survival was obtained for 2.1 Gy delivered as acute dose with parallel-opposed pair (POP), irradiation time 75 s, which served as a reference; regular seven-field IMRT, irradiation time 5 min; and IMRT with a break for multiple leaf collimator (MLC) re-initialization after three fields were delivered, irradiation time 10 min. An actual seven-field dynamic MLC IMRT plan for a head and neck patient was used. The IMRT plan was generated for a Varian EX or iX linear accelerator with 120 leaf Millenium MLC. Survival data were also collected for doses 1x, 2x, 3x, 4x, and 5x 2.1 Gy to establish parameters of the linear-quadratic equation describing survival following acute dose delivery. Cells were irradiated inside an acrylic cylindrical phantom specifically designed for this study. Doses from both IMRT and POP were validated using ion chamber measurements. A reproducible increase in cell survival was observed following IMRT dose delivery. This increase varied from small for V79, with a surviving fraction of 0.8326 following POP vs 0.8420 following uninterrupted IMRT, to very pronounced for SiHa, with a surviving fraction of 0.3903 following POP vs 0.5330 for uninterrupted IMRT. When compared to IMRT or IMRT with a break for MLC initialization, cell survival following acute dose delivery was

  10. Predictors of Radiation Pneumonitis in Patients Receiving Intensity-Modulated Radiation Therapy for Hodgkin and Non-Hodgkin Lymphoma

    Science.gov (United States)

    Pinnix, Chelsea C.; Smith, Grace L.; Milgrom, Sarah; Osborne, Eleanor M.; Reddy, Jay P.; Akhtari, Mani; Reed, Valerie; Arzu, Isidora; Allen, Pamela K.; Wogan, Christine F.; Fanale, Michele A.; Oki, Yasuhiro; Turturro, Francesco; Romaguera, Jorge; Fayad, Luis; Fowler, Nathan; Westin, Jason; Nastoupil, Loretta; Hagemeister, Fredrick B.; Rodriguez, Alma; Ahmed, Sairah; Nieto, Yago; Dabaja, Bouthaina

    2015-01-01

    Purpose Few studies to date have evaluated factors associated with the development of radiation pneumonitis (RP) in patients with Hodgkin lymphoma (HL) and non-Hodgkin lymphoma (NHL), especially in patients treated with contemporary radiation techniques. These patients represent a unique group owing to the often large radiation target volumes within the mediastinum and to the potential to receive several lines of chemotherapy that add to pulmonary toxicity for relapsed or refractory disease. Our objective was to determine the incidence and clinical and dosimetric risk factors associated with RP in lymphoma patients treated with intensity modulated radiation therapy (IMRT) at a single institution. Methods We retrospectively reviewed clinical charts and radiation records of 150 consecutive patients who received mediastinal IMRT for HL and NHL from 2009 through 2013. Clinical and dosimetric predictors associated with RP per the Radiation Therapy Oncology Group (RTOG) acute toxicity criteria were identified in univariate analysis using the Pearson χ2 test and logistic multivariate regression. Results Mediastinal radiation was administered as consolidation therapy in 110 patients with newly diagnosed HL or NHL and in 40 patients with relapsed or refractory disease. The overall incidence of RP (RTOG grade 1–3) was 14% in the entire cohort. Risk of RP was increased for patients who received radiation for relapsed or refractory disease (25%) versus those who received consolidation (10%, P=0.019). Several dosimetric parameters predicted RP, including mean lung dose (MLD) >13.5 Gy, V20 >30%, V15 >35%, V10 >40% and V5>55%. The likelihood ratio (LR) χ2 value was highest for V5mediastinal lymphoma, all dosimetric parameters predicted RP, although small doses to large volumes of lung had the greatest influence. Patients with relapsed or refractory lymphoma who received salvage chemotherapy and hematopoietic stem cell transplantation were at higher risk for symptomatic RP

  11. Predictors of Radiation Pneumonitis in Patients Receiving Intensity Modulated Radiation Therapy for Hodgkin and Non-Hodgkin Lymphoma

    International Nuclear Information System (INIS)

    Pinnix, Chelsea C.; Smith, Grace L.; Milgrom, Sarah; Osborne, Eleanor M.; Reddy, Jay P.; Akhtari, Mani; Reed, Valerie; Arzu, Isidora; Allen, Pamela K.; Wogan, Christine F.; Fanale, Michele A.; Oki, Yasuhiro; Turturro, Francesco; Romaguera, Jorge; Fayad, Luis; Fowler, Nathan; Westin, Jason; Nastoupil, Loretta; Hagemeister, Fredrick B.; Rodriguez, M. Alma

    2015-01-01

    Purpose: Few studies to date have evaluated factors associated with the development of radiation pneumonitis (RP) in patients with Hodgkin lymphoma (HL) and non-Hodgkin lymphoma (NHL), especially in patients treated with contemporary radiation techniques. These patients represent a unique group owing to the often large radiation target volumes within the mediastinum and to the potential to receive several lines of chemotherapy that add to pulmonary toxicity for relapsed or refractory disease. Our objective was to determine the incidence and clinical and dosimetric risk factors associated with RP in lymphoma patients treated with intensity modulated radiation therapy (IMRT) at a single institution. Methods and Materials: We retrospectively reviewed clinical charts and radiation records of 150 consecutive patients who received mediastinal IMRT for HL and NHL from 2009 through 2013. Clinical and dosimetric predictors associated with RP according to Radiation Therapy Oncology Group (RTOG) acute toxicity criteria were identified in univariate analysis using the Pearson χ 2 test and logistic multivariate regression. Results: Mediastinal radiation was administered as consolidation therapy in 110 patients with newly diagnosed HL or NHL and in 40 patients with relapsed or refractory disease. The overall incidence of RP (RTOG grades 1-3) was 14% in the entire cohort. Risk of RP was increased for patients who received radiation for relapsed or refractory disease (25%) versus those who received consolidation therapy (10%, P=.019). Several dosimetric parameters predicted RP, including mean lung dose of >13.5 Gy, V 20 of >30%, V 15 of >35%, V 10 of >40%, and V 5 of >55%. The likelihood ratio χ 2 value was highest for V 5 >55% (χ 2  = 19.37). Conclusions: In using IMRT to treat mediastinal lymphoma, all dosimetric parameters predicted RP, although small doses to large volumes of lung had the greatest influence. Patients with relapsed or refractory lymphoma who received

  12. Predictors of radiation pneumonitis in patients receiving intensity modulated radiation therapy for Hodgkin and non-Hodgkin lymphoma.

    Science.gov (United States)

    Pinnix, Chelsea C; Smith, Grace L; Milgrom, Sarah; Osborne, Eleanor M; Reddy, Jay P; Akhtari, Mani; Reed, Valerie; Arzu, Isidora; Allen, Pamela K; Wogan, Christine F; Fanale, Michele A; Oki, Yasuhiro; Turturro, Francesco; Romaguera, Jorge; Fayad, Luis; Fowler, Nathan; Westin, Jason; Nastoupil, Loretta; Hagemeister, Fredrick B; Rodriguez, M Alma; Ahmed, Sairah; Nieto, Yago; Dabaja, Bouthaina

    2015-05-01

    Few studies to date have evaluated factors associated with the development of radiation pneumonitis (RP) in patients with Hodgkin lymphoma (HL) and non-Hodgkin lymphoma (NHL), especially in patients treated with contemporary radiation techniques. These patients represent a unique group owing to the often large radiation target volumes within the mediastinum and to the potential to receive several lines of chemotherapy that add to pulmonary toxicity for relapsed or refractory disease. Our objective was to determine the incidence and clinical and dosimetric risk factors associated with RP in lymphoma patients treated with intensity modulated radiation therapy (IMRT) at a single institution. We retrospectively reviewed clinical charts and radiation records of 150 consecutive patients who received mediastinal IMRT for HL and NHL from 2009 through 2013. Clinical and dosimetric predictors associated with RP according to Radiation Therapy Oncology Group (RTOG) acute toxicity criteria were identified in univariate analysis using the Pearson χ(2) test and logistic multivariate regression. Mediastinal radiation was administered as consolidation therapy in 110 patients with newly diagnosed HL or NHL and in 40 patients with relapsed or refractory disease. The overall incidence of RP (RTOG grades 1-3) was 14% in the entire cohort. Risk of RP was increased for patients who received radiation for relapsed or refractory disease (25%) versus those who received consolidation therapy (10%, P=.019). Several dosimetric parameters predicted RP, including mean lung dose of >13.5 Gy, V20 of >30%, V15 of >35%, V10 of >40%, and V5 of >55%. The likelihood ratio χ(2) value was highest for V5 >55% (χ(2) = 19.37). In using IMRT to treat mediastinal lymphoma, all dosimetric parameters predicted RP, although small doses to large volumes of lung had the greatest influence. Patients with relapsed or refractory lymphoma who received salvage chemotherapy and hematopoietic stem cell transplantation

  13. Intensity Modulated Radiation Therapy and Image Guided Radiation Therapy: An Overview. Chapter 10

    International Nuclear Information System (INIS)

    Bernhardt, A.C.

    2017-01-01

    Ionizing radiation has been related to medicine since its discovery (see Milestones in Cancer Radiotherapy and Imaging). The ability to visualize the inside of the body by contrasting soft and bone tissues was the first capability of X rays exploited and was the beginning of a path that has brought medical imaging to the heights it occupies today. The harmful side of X rays was only discovered by chance, by Henri Becquerel, and subsequently tested by Pierre Curie, who carried out the first experiment on himself. The use of radiotherapy to treat malignant diseases offered a good alternative to surgery, resulting in a rush during which almost all patients wanted to be treated with it. But the disadvantages were slowly becoming apparent, showing the hazards of ionizing radiation. Minor and major complications were reported, and the ability to induce tumours was recognized. Since then, radiation oncology has become the art of balancing between destroying the tumour and protecting healthy tissues. More than a hundred years of retrieving information and experience from patients has helped build a medical specialty that represents one of the most important modalities to treat, relieve and control cancer.

  14. High-accuracy dosimetry study for intensity-modulated radiation therapy(IMRT) commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hae Sun

    2010-02-15

    Intensity-modulated radiation therapy (IMRT), an advanced modality of high-precision radiotherapy, allows for an increase in dose to the tumor volume without increasing the dose to nearby critical organs. In order to successfully achieve the treatment, intensive dosimetry with accurate dose verification is necessary. A dosimetry for IMRT, however, is a challenging task due to dosimetric ally unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons, non-uniformity between the detector and the phantom materials, and distortion of scanner-read doses. In the present study, therefore, the LEGO-type multi-purpose dosimetry phantom was developed and used for the studies on dose measurements and correction. Phantom materials for muscle, fat, bone, and lung tissue were selected after considering mass density, atomic composition, effective atomic number, and photon interaction coefficients. The phantom also includes dosimeter holders for several different types of detectors including films, which accommodates a construction of different designs of phantoms as necessary. In order to evaluate its performance, the developed phantom was tested by measuring the point dose and the percent depth dose (PDD) for small size fields under several heterogeneous conditions. However, the measurements with the two types of dosimeter did not agree well for the field sizes less than 1 x 1 cm{sup 2} in muscle and bone, and less than 3 x 3 cm{sup 2} in air cavity. Thus, it was recognized that several studies on small fields dosimetry and correction methods for the calculation with a PMCEPT code are needed. The under-estimated values from the ion chamber were corrected with a convolution method employed to eliminate the volume effect of the chamber. As a result, the discrepancies between the EBT film and the ion chamber measurements were significantly decreased, from 14% to 1% (1 x 1 cm{sup 2}), 10% to 1% (0.7 x 0.7 cm{sup 2}), and 42

  15. Impact of geometric uncertainties on dose calculations for intensity modulated radiation therapy of prostate cancer

    Science.gov (United States)

    Jiang, Runqing

    Intensity-modulated radiation therapy (IMRT) uses non-uniform beam intensities within a radiation field to provide patient-specific dose shaping, resulting in a dose distribution that conforms tightly to the planning target volume (PTV). Unavoidable geometric uncertainty arising from patient repositioning and internal organ motion can lead to lower conformality index (CI) during treatment delivery, a decrease in tumor control probability (TCP) and an increase in normal tissue complication probability (NTCP). The CI of the IMRT plan depends heavily on steep dose gradients between the PTV and organ at risk (OAR). Geometric uncertainties reduce the planned dose gradients and result in a less steep or "blurred" dose gradient. The blurred dose gradients can be maximized by constraining the dose objective function in the static IMRT plan or by reducing geometric uncertainty during treatment with corrective verification imaging. Internal organ motion and setup error were evaluated simultaneously for 118 individual patients with implanted fiducials and MV electronic portal imaging (EPI). A Gaussian probability density function (PDF) is reasonable for modeling geometric uncertainties as indicated by the 118 patients group. The Gaussian PDF is patient specific and group standard deviation (SD) should not be used for accurate treatment planning for individual patients. In addition, individual SD should not be determined or predicted from small imaging samples because of random nature of the fluctuations. Frequent verification imaging should be employed in situations where geometric uncertainties are expected. Cumulative PDF data can be used for re-planning to assess accuracy of delivered dose. Group data is useful for determining worst case discrepancy between planned and delivered dose. The margins for the PTV should ideally represent true geometric uncertainties. The measured geometric uncertainties were used in this thesis to assess PTV coverage, dose to OAR, equivalent

  16. Simultaneous integrated boost-intensity modulated radiation therapy for inoperable hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyun; Park, Joong-Won; Kim, Yeon-Joo; Kim, Bo Hyun; Woo, Sang Myung; Moon, Sung Ho; Kim, Sang Soo; Lee, Woo Jin; Kim, Dae Yong; Kim, Chang-Min [National Cancer Center, Center for Liver Cancer, Research Institute and Hospital, Goyang-si, Gyeonggi-do (Korea, Republic of)

    2014-10-15

    The aim of this work was to evaluate the clinical efficacy and safety of simultaneous integrated boost-intensity modulated radiation therapy (SIB-IMRT) in patients with inoperable hepatocellular carcinoma (HCC). A total of 53 patients with inoperable HCC underwent SIB-IMRT using two dose-fractionation schemes, depending on the proximity of gastrointestinal structures. The 41 patients in the low dose-fractionation (LD) group, with internal target volume (ITV) < 1 cm from gastrointestinal structures, received total doses of 55 and 44 Gy in 22 fractions to planning target volume 1 (PTV1) and 2 (PTV2), respectively. The 12 patients in the high dose-fractionation (HD) group, with ITV ≥ 1 cm from gastrointestinal structures, received total doses of 66 and 55 Gy in 22 fractions to the PTV1 and PTV2, respectively. Overall, treatment was well tolerated, with no grade > 3 toxicity. The LD group had larger sized tumors (median: 6 vs. 3.4 cm) and greater frequencies of vascular invasion (80.6 vs. 16.7 %) than patients in the HD group (p < 0.05 each). The median overall survival (OS) was 25.1 months and the actuarial 2-year local progression-free survival (LPFS), relapse-free survival (RFS), and OS rates were 67.3, 14.7, and 54.7 %, respectively. The HD group tended to show better tumor response (100 vs. 62.2 %, p = 0.039) and 2-year LPFS (85.7 vs. 59 %, p = 0.119), RFS (38.1 vs. 7.3 %, p = 0.063), and OS (83.3 vs. 44.3 %, p = 0.037) rates than the LD group. Multivariate analysis showed that tumor response was significantly associated with OS. SIB-IMRT is feasible and safe for patients with inoperable HCC. (orig.) [German] Ziel der Arbeit war es, die klinische Wirksamkeit und die Sicherheit der intensitaetsmodulierten Radiotherapie mit simultanem integriertem Boost (SIB-IMRT) fuer Patienten mit einem inoperablen hepatozellulaeren Karzinom (HCC) zu evaluieren. Bei 53 Patienten mit inoperablem HCC wurden zwei unterschiedliche Dosierungskonzepte je nach Lagebeziehung des

  17. A novel conformity index for intensity modulated radiation therapy plan evaluation.

    Science.gov (United States)

    Cheung, Fion W K; Law, Maria Y Y

    2012-09-01

    Intensity modulated radiation therapy (IMRT) has gained popularity in the treatment of cancers. Manual evaluation of IMRT plans for head-and-neck cancers has been especially challenging necessitating efficient and objective assessment tools. In this work, the authors address this issue by developing a personalized conformity index (CI) for comparison of IMRT plans for head-and-neck cancers and evaluating its plan quality discerning power in comparison with other widely used CIs. A two-dimensional CI with dose and distance incorporated (CI(DD)) was developed using the MATLAB program language, to quantify the planning target volume (PTV) coverage. Valuable information contained in the digital imaging and communication in medicine (DICOM) RT objects were harvested for computation of each of the CI(DD) components. Apart from the dose penalty factor, a distance-based exponential function was employed by varying the penalty weight associated with the location of cold spots within the PTV. With the goal of deriving a customized penalty factor, the distances between individual pixel and its nearest PTV boundary was found. Using the exponential function, the impact of distance penalty was substantially larger for cold spots closer to the PTV centroid but petered out quickly wherever they were situated in the vicinity of PTV border. In order to evaluate the CI(DD) scoring system, three CT image data sets of nasopharyngeal carcinoma (NPC) patients were collected. Ten IMRT plans with degrading qualities were generated from each dataset and were ranked based on CI(DD) and other existing indices. The coefficient of variance was calculated for each dataset to compare the degree of variation. The CI(DD) scoring system that considered spatial importance of each voxel within the PTV was successfully developed. The results demonstrated that the CI(DD) including four discrete factors could provide accurate rankings of plan quality by examining the relative importance of each cold spot

  18. Imaging Changes in Pediatric Intracranial Ependymoma Patients Treated With Proton Beam Radiation Therapy Compared to Intensity Modulated Radiation Therapy

    International Nuclear Information System (INIS)

    Gunther, Jillian R.; Sato, Mariko; Chintagumpala, Murali; Ketonen, Leena; Jones, Jeremy Y.; Allen, Pamela K.; Paulino, Arnold C.; Okcu, M. Fatih; Su, Jack M.; Weinberg, Jeffrey; Boehling, Nicholas S.; Khatua, Soumen; Adesina, Adekunle; Dauser, Robert; Whitehead, William E.; Mahajan, Anita

    2015-01-01

    Purpose: The clinical significance of magnetic resonance imaging (MRI) changes after radiation therapy (RT) in children with ependymoma is not well defined. We compared imaging changes following proton beam radiation therapy (PBRT) to those after photon-based intensity modulated RT (IMRT). Methods and Materials: Seventy-two patients with nonmetastatic intracranial ependymoma who received postoperative RT (37 PBRT, 35 IMRT) were analyzed retrospectively. MRI images were reviewed by 2 neuroradiologists. Results: Sixteen PBRT patients (43%) developed postradiation MRI changes at 3.8 months (median) with resolution by 6.1 months. Six IMRT patients (17%) developed changes at 5.3 months (median) with 8.3 months to resolution. Mean age at radiation was 4.4 and 6.9 years for PBRT and IMRT, respectively (P=.06). Age at diagnosis (>3 years) and time of radiation (≥3 years) was associated with fewer imaging changes on univariate analysis (odds ratio [OR]: 0.35, P=.048; OR: 0.36, P=.05). PBRT (compared to IMRT) was associated with more frequent imaging changes, both on univariate (OR: 3.68, P=.019) and multivariate (OR: 3.89, P=.024) analyses. Seven (3 IMRT, 4 PBRT) of 22 patients with changes had symptoms requiring intervention. Most patients were treated with steroids; some PBRT patients also received bevacizumab and hyperbaric oxygen therapy. None of the IMRT patients had lasting deficits, but 2 patients died from recurrent disease. Three PBRT patients had persistent neurological deficits, and 1 child died secondarily to complications from radiation necrosis. Conclusions: Postradiation MRI changes are more common with PBRT and in patients less than 3 years of age at diagnosis and treatment. It is difficult to predict causes for development of imaging changes that progress to clinical significance. These changes are usually self-limiting, but some require medical intervention, especially those involving the brainstem

  19. Imaging Changes in Pediatric Intracranial Ependymoma Patients Treated With Proton Beam Radiation Therapy Compared to Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Gunther, Jillian R. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Sato, Mariko; Chintagumpala, Murali [Department of Pediatrics, Section of Hematology-Oncology, Baylor College of Medicine, Texas Children' s Cancer Center, Houston, Texas (United States); Ketonen, Leena [Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Jones, Jeremy Y. [Department of Pediatric Radiology, Texas Children' s Hospital, Houston, Texas (United States); Allen, Pamela K. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Paulino, Arnold C. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Pediatrics, Section of Hematology-Oncology, Baylor College of Medicine, Texas Children' s Cancer Center, Houston, Texas (United States); Okcu, M. Fatih; Su, Jack M. [Department of Pediatrics, Section of Hematology-Oncology, Baylor College of Medicine, Texas Children' s Cancer Center, Houston, Texas (United States); Weinberg, Jeffrey [Department of Neurosurgery, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Boehling, Nicholas S. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Khatua, Soumen [Department of Pediatrics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Adesina, Adekunle [Department of Pathology, Baylor College of Medicine, Texas Children' s Hospital, Houston, Texas (United States); Dauser, Robert; Whitehead, William E. [Department of Neurosurgery, Texas Children' s Hospital, Houston, Texas (United States); Mahajan, Anita, E-mail: amahajan@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2015-09-01

    Purpose: The clinical significance of magnetic resonance imaging (MRI) changes after radiation therapy (RT) in children with ependymoma is not well defined. We compared imaging changes following proton beam radiation therapy (PBRT) to those after photon-based intensity modulated RT (IMRT). Methods and Materials: Seventy-two patients with nonmetastatic intracranial ependymoma who received postoperative RT (37 PBRT, 35 IMRT) were analyzed retrospectively. MRI images were reviewed by 2 neuroradiologists. Results: Sixteen PBRT patients (43%) developed postradiation MRI changes at 3.8 months (median) with resolution by 6.1 months. Six IMRT patients (17%) developed changes at 5.3 months (median) with 8.3 months to resolution. Mean age at radiation was 4.4 and 6.9 years for PBRT and IMRT, respectively (P=.06). Age at diagnosis (>3 years) and time of radiation (≥3 years) was associated with fewer imaging changes on univariate analysis (odds ratio [OR]: 0.35, P=.048; OR: 0.36, P=.05). PBRT (compared to IMRT) was associated with more frequent imaging changes, both on univariate (OR: 3.68, P=.019) and multivariate (OR: 3.89, P=.024) analyses. Seven (3 IMRT, 4 PBRT) of 22 patients with changes had symptoms requiring intervention. Most patients were treated with steroids; some PBRT patients also received bevacizumab and hyperbaric oxygen therapy. None of the IMRT patients had lasting deficits, but 2 patients died from recurrent disease. Three PBRT patients had persistent neurological deficits, and 1 child died secondarily to complications from radiation necrosis. Conclusions: Postradiation MRI changes are more common with PBRT and in patients less than 3 years of age at diagnosis and treatment. It is difficult to predict causes for development of imaging changes that progress to clinical significance. These changes are usually self-limiting, but some require medical intervention, especially those involving the brainstem.

  20. Breast-conserving radiation therapy using combined electron and intensity-modulated radiotherapy technique

    International Nuclear Information System (INIS)

    Li, J.G.; Williams, S.S.; Goffinet, D.R.; Boer, A.L.; Xing, L.

    2000-01-01

    An electron beam with appropriate energy was combined with four intensity modulated photon beams. The direction of the electron beam was chosen to be tilted 10-20 laterally from the anteroposterior direction. Two of the intensity-modulated photon beams had the same gantry angles as the conventional tangential fields, whereas the other two beams were rotated 15-25' toward the anteroposterior directions from the first two photon beams. An iterative algorithm was developed which optimizes the weight of the electron beam as well as the fluence profiles of the photon beams for a given patient. Two breast cancer patients with early-stage breast tumors were planned with the new technique and the results were compared with those from 3D planning using tangential fields as well as 9-field intensity-modulated radiotherapy (IMRT) techniques. The combined electron and IMRT plans showed better dose conformity to the target with significantly reduced dose to the ipsilateral lung and, in the case of the left-breast patient, reduced dose to the heart, than the tangential field plans. In both the right-sided and left-sided breast plans, the dose to other normal structures was similar to that from conventional plans and was much smaller than that from the 9-field IMRT plans. The optimized electron beam provided between 70 to 80% of the prescribed dose at the depth of maximum dose of the electron beam. The combined electron and IMRT technique showed improvement over the conventional treatment technique using tangential fields with reduced dose to the ipsilateral lung and the heart. The customized beam directions of the four IMRT fields also kept the dose to other critical structures to a minimum. (author)

  1. Whole-brain hippocampal sparing radiation therapy: Volume-modulated arc therapy vs intensity-modulated radiation therapy case study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Katrina, E-mail: Trinabena23@gmail.com; Lenards, Nishele; Holson, Janice

    2016-04-01

    The hippocampus is responsible for memory and cognitive function. An ongoing phase II clinical trial suggests that sparing dose to the hippocampus during whole-brain radiation therapy can help preserve a patient's neurocognitive function. Progressive research and advancements in treatment techniques have made treatment planning more sophisticated but beneficial for patients undergoing treatment. The aim of this study is to evaluate and compare hippocampal sparing whole-brain (HS-WB) radiation therapy treatment planning techniques using volume-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT). We randomly selected 3 patients to compare different treatment techniques that could be used for reducing dose to the hippocampal region. We created 2 treatment plans, a VMAT and an IMRT, from each patient's data set and planned on the Eclipse 11.0 treatment planning system (TPS). A total of 6 plans (3 IMRT and 3 VMAT) were created and evaluated for this case study. The physician contoured the hippocampus as per the Radiation Therapy Oncology Group (RTOG) 0933 protocol atlas. The organs at risk (OR) were contoured and evaluated for the plan comparison, which included the spinal cord, optic chiasm, the right and left eyes, lenses, and optic nerves. Both treatment plans produced adequate coverage on the planning target volume (PTV) while significantly reducing dose to the hippocampal region. The VMAT treatment plans produced a more homogenous dose distribution throughout the PTV while decreasing the maximum point dose to the target. However, both treatment techniques demonstrated hippocampal sparing when irradiating the whole brain.

  2. First Experiences in Intensity Modulated Radiation Surgery at the National Institute of Neurology and Neurosurgery: A Dosimetric Point of View

    International Nuclear Information System (INIS)

    Larraga-Gutierrez, Jose M.; Celis-Lopez, Miguel A.

    2003-01-01

    The National Institute of Neurology and Neurosurgery in Mexico City has acquired a Novalis registered shaped beam radiosurgery unit. The institute is pioneer in the use of new technologies for neuroscience. The Novalis registered unit allows the use of conformal beam radiosurgery/therapy and the more advanced modality of conformal therapy: Intensity Modulated Radiation Therapy (IMRT). In the present work we present the first cases of treatments that use the IMRT technique and show its ability to protect organs at risk, such as brainstem and optical vias

  3. First Experiences in Intensity Modulated Radiation Surgery at the National Institute of Neurology and Neurosurgery: A Dosimetric Point of View

    Science.gov (United States)

    Lárraga-Gutiérrez, José M.; Celis-López, Miguel A.

    2003-09-01

    The National Institute of Neurology and Neurosurgery in Mexico City has acquired a Novalis® shaped beam radiosurgery unit. The institute is pioneer in the use of new technologies for neuroscience. The Novalis® unit allows the use of conformal beam radiosurgery/therapy and the more advanced modality of conformal therapy: Intensity Modulated Radiation Therapy (IMRT). In the present work we present the first cases of treatments that use the IMRT technique and show its ability to protect organs at risk, such as brainstem and optical vias.

  4. Predictors of Radiation Pneumonitis in Patients Receiving Intensity Modulated Radiation Therapy for Hodgkin and Non-Hodgkin Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Pinnix, Chelsea C., E-mail: ccpinnix@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Smith, Grace L.; Milgrom, Sarah; Osborne, Eleanor M.; Reddy, Jay P.; Akhtari, Mani; Reed, Valerie; Arzu, Isidora; Allen, Pamela K.; Wogan, Christine F. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Fanale, Michele A.; Oki, Yasuhiro; Turturro, Francesco; Romaguera, Jorge; Fayad, Luis; Fowler, Nathan; Westin, Jason; Nastoupil, Loretta; Hagemeister, Fredrick B.; Rodriguez, M. Alma [Department of Lymphoma/Myeloma, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); and others

    2015-05-01

    Purpose: Few studies to date have evaluated factors associated with the development of radiation pneumonitis (RP) in patients with Hodgkin lymphoma (HL) and non-Hodgkin lymphoma (NHL), especially in patients treated with contemporary radiation techniques. These patients represent a unique group owing to the often large radiation target volumes within the mediastinum and to the potential to receive several lines of chemotherapy that add to pulmonary toxicity for relapsed or refractory disease. Our objective was to determine the incidence and clinical and dosimetric risk factors associated with RP in lymphoma patients treated with intensity modulated radiation therapy (IMRT) at a single institution. Methods and Materials: We retrospectively reviewed clinical charts and radiation records of 150 consecutive patients who received mediastinal IMRT for HL and NHL from 2009 through 2013. Clinical and dosimetric predictors associated with RP according to Radiation Therapy Oncology Group (RTOG) acute toxicity criteria were identified in univariate analysis using the Pearson χ{sup 2} test and logistic multivariate regression. Results: Mediastinal radiation was administered as consolidation therapy in 110 patients with newly diagnosed HL or NHL and in 40 patients with relapsed or refractory disease. The overall incidence of RP (RTOG grades 1-3) was 14% in the entire cohort. Risk of RP was increased for patients who received radiation for relapsed or refractory disease (25%) versus those who received consolidation therapy (10%, P=.019). Several dosimetric parameters predicted RP, including mean lung dose of >13.5 Gy, V{sub 20} of >30%, V{sub 15} of >35%, V{sub 10} of >40%, and V{sub 5} of >55%. The likelihood ratio χ{sup 2} value was highest for V{sub 5} >55% (χ{sup 2} = 19.37). Conclusions: In using IMRT to treat mediastinal lymphoma, all dosimetric parameters predicted RP, although small doses to large volumes of lung had the greatest influence. Patients with relapsed

  5. Three-dimensional conformal radiation therapy: the tomo-therapy approach

    International Nuclear Information System (INIS)

    Linthout, N.; Verellen, D.; Coninck, P. de; Bel, A.; Storme, G.

    2000-01-01

    Conformal radiation therapy allows the possibility of delivering high doses at the tumor volume whilst limiting the dose to the surrounding tissues and diminishing the secondary effects. With the example of the conformal radiation therapy used at the AZ VU8 (3DCRT and tomo-therapy), two treatment plans of a left ethmoid carcinoma will be evaluated and discussed in detail. The treatment of ethmoid cancer is technically difficult for both radiation therapy and surgery because of the anatomic constraints and patterns of local spread. A radiation therapy is scheduled to be delivered after surgical resection of the tumor. The treatment plan for the radiation therapy was calculated on a three-dimensional (3D) treatment planning system based on virtual simulation with a beam's eye view: George Sherouse's Gratis. An effort was made to make the plan as conformal and as homogeneous as possible to deliver a dose of 66 Gy in 33 fractions at the tumor bed with a maximum dose of 56 Gy to the right optic nerve and the chiasma. To establish the clinical utility and potential advantages of tomo-therapy over 3DCRT for ethmoid carcinoma, the treatment of this patient was also planned with Peacock Plant. For both treatment plans the isodose distributions and cumulative dose volume histograms (CDVH) were computed. Superimposing the CDVHs yielded similar curves for the target and an obvious improvement for organs at risk such as the chiasma, brainstem and the left eye when applying tomo-therapy. These results have also been reflected in the tumor control probabilities (equal for both plans) and the normal tissue complication probabilities (NTCP), yielding significant reductions in NTCP for tomo-therapy. The probability of uncomplicated tumor control was 52.7% for tomo-therapy against 38.3% for 3DCRT. (authors)

  6. Application of dynamic intensity-modulated radiation therapy to the treatment of prostate cancer

    International Nuclear Information System (INIS)

    Engler, Mark J.; Tsai, J.-S.; Vora, Sujay; Wazer, David E.; Di Petrillo, Thomas

    1997-01-01

    Objectives: To apply safe, reliable dynamic intensity-modulated radiation therapy (IMRT) to the treatment of prostate cancer, and to compare IMRT prostatic dose distributions to those of three dimensional conformal radiation therapy (3DCRT). Methods and Materials: Twelve patients with prostate adenocarcinoma were CT-simulated for dynamic IMRT planning, plan and plan verification, and treatment and treatment verification. IMRT was planned with dose optimization based on simulated annealing, and delivered with a pencil beam collimator affixed to a high dose rate 6 MV linear accelerator. Seven received primary therapy of 35 fractions (Fx) x 2 Gy/Fx = 70 Gy at isodose surfaces of 80 - 87% of maximum dose. The first 22 Fx were prescribed to the gross tumor volume (GTV) with a 1 cm margin, and subsequent 13 Fx prescribed to GTV with a 5 mm margin. Five patients were boosted with 14 - 24 Gy of IMRT after 45 - 55 Gy of 4 - 6 field 3DCRT, to 69 - 71 Gy. All patients' feet were immobilized in foot stocks, or by taping both feet to a styrofoam block. Seven patients were positioned with customized polyurethane posterior-lateral-perineal supports (saddles), four, with anterior thermoplastic casts, and one was positioned without a pelvic device. Target positional reproducibility was studied with gold seeds at stategic prostatic locations (apex, base, rt and lt lateral), barium fiducial marks, rectal balloon catheters with lead markers, and skin and device laser alignment marks. Delineator lines were placed on CT simulator films at borders of IMRT field matchlines for comparison with port films exposed to adjacent 4 x 20 cm fields of the fully open collimator. Plans were verified with films in an anthropomorphic phantom adjusted with bolus to approximate patient geometry. 'Treatment films' were exposed under the patient for the entire treatment to measure spatial accuracy of matchlines. Significance of matchline and positioning errors was assessed with biological models. Rectal

  7. Monte Carlo evaluation of Acuros XB dose calculation Algorithm for intensity modulated radiation therapy of nasopharyngeal carcinoma

    Science.gov (United States)

    Yeh, Peter C. Y.; Lee, C. C.; Chao, T. C.; Tung, C. J.

    2017-11-01

    Intensity-modulated radiation therapy is an effective treatment modality for the nasopharyngeal carcinoma. One important aspect of this cancer treatment is the need to have an accurate dose algorithm dealing with the complex air/bone/tissue interface in the head-neck region to achieve the cure without radiation-induced toxicities. The Acuros XB algorithm explicitly solves the linear Boltzmann transport equation in voxelized volumes to account for the tissue heterogeneities such as lungs, bone, air, and soft tissues in the treatment field receiving radiotherapy. With the single beam setup in phantoms, this algorithm has already been demonstrated to achieve the comparable accuracy with Monte Carlo simulations. In the present study, five nasopharyngeal carcinoma patients treated with the intensity-modulated radiation therapy were examined for their dose distributions calculated using the Acuros XB in the planning target volume and the organ-at-risk. Corresponding results of Monte Carlo simulations were computed from the electronic portal image data and the BEAMnrc/DOSXYZnrc code. Analysis of dose distributions in terms of the clinical indices indicated that the Acuros XB was in comparable accuracy with Monte Carlo simulations and better than the anisotropic analytical algorithm for dose calculations in real patients.

  8. Intensity modulated conformal radiotherapy

    International Nuclear Information System (INIS)

    Noel, Georges; Moty-Monnereau, Celine; Meyer, Aurelia; David, Pauline; Pages, Frederique; Muller, Felix; Lee-Robin, Sun Hae; David, Denis Jean

    2006-12-01

    This publication reports the assessment of intensity-modulated conformal radiotherapy (IMCR). This assessment is based on a literature survey which focussed on indications, efficiency and safety on the short term, on the risk of radio-induced cancer on the long term, on the role in the therapeutic strategy, on the conditions of execution, on the impact on morbidity-mortality and life quality, on the impact on the health system and on public health policies and program. This assessment is also based on the opinion of a group of experts regarding the technical benefit of IMCR, its indications depending on the cancer type, safety in terms of radio-induced cancers, and conditions of execution. Before this assessment, the report thus indicates indications for which the use of IMCR can be considered as sufficient or not determined. It also proposes a technical description of IMCR and helical tomo-therapy, discusses the use of this technique for various pathologies or tumours, analyses the present situation of care in France, and comments the identification of this technique in foreign classifications

  9. Acute Toxicity After Image-Guided Intensity Modulated Radiation Therapy Compared to 3D Conformal Radiation Therapy in Prostate Cancer Patients

    NARCIS (Netherlands)

    Wortel, Ruud C.; Incrocci, Luca; Pos, Floris J.; Lebesque, Joos V.; Witte, Marnix G.; van der Heide, Uulke A.; van Herk, Marcel; Heemsbergen, Wilma D.

    2015-01-01

    Purpose: Image-guided intensity modulated radiation therapy (IG-IMRT) allows significant dose reductions to organs at risk in prostate cancer patients. However, clinical data identifying the benefits of IG-IMRT in daily practice are scarce. The purpose of this study was to compare dose distributions

  10. Design, simulation and manufacture of a multi leaf collimator to confirm the target volumes in intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Kamali-Asl, A.; Batooli, A. H.; Harriri, S.; Salman-Rezaee, F.; Shahmardan, F.; Yavari, L.

    2010-01-01

    Intensity modulated radiation therapy is one of the cancer treatment methods. It is important to selectively aim at the target in this way, which can be performed using a multi leaf collimator. Materials and Methods: In order to specifically irradiate the target volume in radiotherapy to reduce the patient absorbed dose, the use of multi leaf collimator has been investigated in this work. Design and simulation of an multi leaf collimator was performed by a Monte Carlo method and the optimum material for manufacturing the leaves was determined using MCNP4C. After image processing (CT or MRI) in this system, the tumor configuration is determined. Then the linear accelerator is switched on and the beam irradiates the cancerous cells. When the multi leaf collimator leaves receive a command from the micro controller, they start to move and absorb the radiation and modulate its intensity. Consequently, the tumor receives maximum intensity of radiation but minimum intensity is delivered to healthy tissues. Results: According to the simulations and calculations, the best material to manufacture the leaves from is tungsten alloy containing copper and nickel which absorbs a large amount of the radiation; by using a 8.65 cm thickness of alloy, 10.55% of radiation will transmit through the leaves. Discussion and Conclusion: Lead blocks are conventionally used in radiotherapy. However, they have some problems like cost, storage and manufacture for every patient. Certainly, the multi leaf collimator is the most efficient device to specifically irradiate the tumor in Intensity modulated radiation therapy. Furthermore, it facilitates treating the target in different views by rotation around the patient. Thus the patient's absorbed dose will decrease and the tumor will receive maximum dose.

  11. Outcome of three-dimensional conformal radiation therapy and intensity-modulated radiation therapy for inoperable locally advanced pancreatic cancer

    International Nuclear Information System (INIS)

    Lu Ningning; Jin Jing; Li Yexiong; Yu Zihao; Liu Xinfan; Wang Weihu; Wang Shulian; Song Yongwen; Liu Yuping

    2009-01-01

    Objective: To evaluate the outcome of radiotherapy for locally advanced pancreatic cancer. Methods: From January 2000 to December 2007, 41 patients with inoperable locally advanced (stage III) pancreatic cancer were treated with three-dimensional conformal radiation therapy(3DCRT) or intensity-modulated radiation therapy (IMRT). Among these patients, 30 received concurrent radio-chemo-therapy. Results: The median survival time(MST) and 1-year overall survival were 9.2 months and 23%. Patients with pretreatment KPS ≥ 80, no regional lymph nodes metastasis, and CR/PR after radiotherapy had better prognosis. The corresponding MSTs were 11.1 months vs 5.8 months (χ 2 =7.50, P=0.006), 10.8 months vs 6.5 months(χ 2 =5.67, P=0.017), and 19.5 months vs 9.1 months (χ 2 =7.28, P=0.007), respectively. Concurrent radio-chemotherapy tended to improve the overall survival(χ 2 =3.25, P=0.072). After radiotherapy, 18 patients had clinical benefit response, mainly being abdominal pain relief. Neither grade 4 hematologic nor grade 3 non-hematologic toxicities were observed. Conclusions: For patients with locally advanced pancreatic cancer, both 3DCRT and IMRT are effective in alleviation of disease-related symptoms. Patients with better performance status before treatment, no regional lymph nodes metastasis, and better response to radiotherapy may have better prognosis. Concurrent radio-chemotherapy trend to improve overall survival when compared with radiotherapy alone. (authors)

  12. Multimodal hypoxia imaging and intensity modulated radiation therapy for unresectable non-small-cell lung cancer: the HIL trial

    Directory of Open Access Journals (Sweden)

    Askoxylakis Vasileios

    2012-09-01

    Full Text Available Abstract Background Radiotherapy, preferably combined with chemotherapy, is the treatment standard for locally advanced, unresectable non-small cell lung cancer (NSCLC. The tumor response to different therapy protocols is variable, with hypoxia known to be a major factor that negatively influences treatment effectiveness. Visualisation of tumor hypoxia prior to the use of modern radiation therapy strategies, such as intensity modulated radiation therapy (IMRT, might allow optimized dose applications to the target volume, leading to improvement of therapy outcome. 18 F-fluoromisonidazole dynamic positron emission tomography and computed tomography (18 F-FMISO dPET-CT and functional magnetic resonance imaging (functional MRI are attractive options for imaging tumor hypoxia. Methods/design The HIL trial is a single centre study combining multimodal hypoxia imaging with 18 F-FMISO dPET-CT and functional MRI, with intensity modulated radiation therapy (IMRT in patients with inoperable stage III NSCLC. 15 patients will be recruited in the study. All patients undergo initial FDG PET-CT and serial 18 F-FMISO dPET-CT and functional MRI before treatment, at week 5 of radiotherapy and 6 weeks post treatment. Radiation therapy is performed as inversely planned IMRT based on 4D-CT. Discussion Primary objectives of the trial are to characterize the correlation of 18 F-FMISO dPET-CT and functional MRI for tumor hypoxia imaging in NSCLC and evaluate possible effects of radiation therapy on tumor re-oxygenation. Further objectives include the generation of data regarding the prognostic value of 18 F-FMISO dPET-CT and functional MRI for locoregional control, progression free survival and overall survival of NSCLC treated with IMRT, which will form the basis for larger clinical trials focusing on possible interactions between tumor oxygenation and radiotherapy outcome. Trial registration The ClinicalTrials.gov protocol ID is NCT01617980

  13. Comparison of a new noncoplanar intensity-modulated radiation therapy technique for craniospinal irradiation with 3 coplanar techniques

    DEFF Research Database (Denmark)

    Hansen, Anders T; Lukacova, Slavka; Lassen-Ramshad, Yasmin A.

    2015-01-01

    When standard conformal x-ray technique for craniospinal irradiation is used, it is a challenge to achieve satisfactory dose coverage of the target including the area of the cribriform plate, while sparing organs at risk. We present a new intensity-modulated radiation therapy (IMRT), noncoplanar...... patient using the noncoplanar IMRT-based technique, a coplanar IMRT-based technique, and a coplanar volumetric-modulated arch therapy (VMAT) technique. Dosimetry data for all patients were compared with the corresponding data from the conventional treatment plans. The new noncoplanar IMRT technique...... substantially reduced the mean dose to organs at risk compared with the standard radiation technique. The 2 other coplanar techniques also reduced the mean dose to some of the critical organs. However, this reduction was not as substantial as the reduction obtained by the noncoplanar technique. Furthermore...

  14. Dependence of Achievable Plan Quality on Treatment Technique and Planning Goal Refinement: A Head-and-Neck Intensity Modulated Radiation Therapy Application

    International Nuclear Information System (INIS)

    Qi, X. Sharon; Ruan, Dan; Lee, Steve P.; Pham, Andrew; Kupelian, Patrick; Low, Daniel A.; Steinberg, Michael; Demarco, John

    2015-01-01

    Purpose: To develop a practical workflow for retrospectively analyzing target and normal tissue dose–volume endpoints for various intensity modulated radiation therapy (IMRT) delivery techniques; to develop technique-specific planning goals to improve plan consistency and quality when feasible. Methods and Materials: A total of 165 consecutive head-and-neck patients from our patient registry were selected and retrospectively analyzed. All IMRT plans were generated using the same dose–volume guidelines for TomoTherapy (Tomo, Accuray), TrueBeam (TB, Varian) using fixed-field IMRT (TB-IMRT) or RAPIDARC (TB-RAPIDARC), or Siemens Oncor (Siemens-IMRT, Siemens). A MATLAB-based dose–volume extraction and analysis tool was developed to export dosimetric endpoints for each patient. With a fair stratification of patient cohort, the variation of achieved dosimetric endpoints was analyzed among different treatment techniques. Upon identification of statistically significant variations, technique-specific planning goals were derived from dynamically accumulated institutional data. Results: Retrospective analysis showed that although all techniques yielded comparable target coverage, the doses to the critical structures differed. The maximum cord doses were 34.1 ± 2.6, 42.7 ± 2.1, 43.3 ± 2.0, and 45.1 ± 1.6 Gy for Tomo, TB-IMRT, TB-RAPIDARC, and Siemens-IMRT plans, respectively. Analyses of variance showed significant differences for the maximum cord doses but no significant differences for other selected structures among the investigated IMRT delivery techniques. Subsequently, a refined technique-specific dose–volume guideline for maximum cord dose was derived at a confidence level of 95%. The dosimetric plans that failed the refined technique-specific planning goals were reoptimized according to the refined constraints. We observed better cord sparing with minimal variations for the target coverage and other organ at risk sparing for the Tomo cases, and higher

  15. Inverse treatment planning for intensity modulated radiation therapy: CDVH treatment prescription with integral cost function

    International Nuclear Information System (INIS)

    Carol, M.P.; Nash, R.; Campbell, R.C.; Huber, R.

    1997-01-01

    Purpose/Objective: Inverse planning is a required approach when dealing with the complexity of variables present in an intensity modulated plan. However, an inverse planning system is only as useful as it is 1) easy to use and 2) predictable in its result. This is especially the case when the target goals and structure limits specified by the user all cannot be achieved. We have previously developed two interfaces for specifying how such conflicts should be resolved when they occur, that, although allowing a range of results to be obtained, still require 'trial and error' on the part of the user and are case dependent. A new method is explored with goals of allowing the desired results to be specified in an intuitive manner and producing predictable results that are case independent. Materials and Methods: Target goals and structure limits are specified by entering partial volume data: goal/limit, % under/over goal/limit, minimum, maximum. This data is converted to a CDVH curve for each target/structure. During the simulated annealing process used to produce an optimized solution, the actual CDVHs are compared to the desired CDVHs after each iteration and a cost is computed for the difference between the curves. For each curve, the cost is proportional to the difference in area between the desired and actual curves. This cost is controlled by three variables: offset (amount of difference before there is any cost), scale (the range the cost can take) and shape (the shape of the curve for difference versus cost). A range of values were explored for these variables in order to determine if predictable trade-offs would be made automatically by the system. The cost function was tested against a range of cases: a highly irregularly shaped intracranial lesion, a head and neck case with three target volumes with different prescriptions, and a prostate cancer. Results: By varying the values assigned to the control variables, a variety of predictable results could be

  16. Survival benefit of adding chemotherapy to intensity modulated radiation in patients with locoregionally advanced nasopharyngeal carcinoma.

    Directory of Open Access Journals (Sweden)

    Xuemei Ji

    Full Text Available BACKGROUND: To evaluate the contribution of chemotherapy for patients with locoregionally advanced nasopharyngeal carcinoma (NPC treated by intensity modulated radiotherapy (IMRT and to identify the optimal combination treatment strategy. PATIENTS AND METHODS: Between 2006 and 2010, 276 patients with stage II-IVb NPC were treated by IMRT alone or IMRT plus chemotherapy. Cisplatin-based chemotherapy included neoadjuvant or concurrent, or neoadjuvant plus concurrent protocols. The IMRT alone and chemoradiotherapy groups were well-matched for prognostic factors, except N stage, with more advanced NPC in the chemoradiotherapy arm. RESULTS: With a mean follow-up of 33.8 months, the 3-year actuarial rates of overall survival (OS, metastasis-free survival (MFS, relapse-free survival (RFS, and disease-free survival (DFS were 90.3%, 84.2%, 80.3%, and 69.2% for all of the patients, respectively. Compared with the IMRT alone arm, patients treated by concurrent chemoradiotherapy had a significantly better DFS (HR = 2.64; 95% CI, 1.12-6.22; P = 0.03, patients with neoadjuvant-concurrent chemoradiotherapy had a significant improvement in RFS and DFS (HR = 4.03; 95% CI, 1.35-12.05; P = 0.01 and HR = 2.43; 95% CI, 1.09-5.44; P = 0.03, neoadjuvant chemoradiotherapy provided no significant benefit in OS, MFS, RFS, and DFS. Stage group and alcohol consumption were prognostic factors for OS and N stage was a significant predictor for DFS. CONCLUSIONS: Addition of concurrent or neoadjuvant-concurrent chemotherapy to IMRT is available to prolong RFS or DFS for locoregionally advanced NPC. Such work could be helpful to guide effective individualized therapy.

  17. Long-term Patterns of Regional Failure for Nasopharyngeal Carcinoma following Intensity-Modulated Radiation Therapy

    Science.gov (United States)

    Xue, Fen; Hu, Chaosu; He, Xiayun

    2017-01-01

    Purpose: To analyze the long-term patterns of regional failure following intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC). Methods: From January 2005 to December 2010, 275 non-metastatic NPC patients treated with IMRT were retrospectively enrolled. Patients staged as II (lymph nodes measuring 4 or more cm in diameter), III or IV also received chemotherapy. Failures were assessed as in-field or out-field relative to the pretreatment planning computed tomography data sets. Univariate and multivariate analyses were performed with Cox proportional hazards model to analyze the effect of various prognostic factors on regional failure-free survival (RFFS) and overall survival (OS). Results: During a median follow-up of 71 months, the RFFS and OS rates were 94.3% and 83.9%, respectively. Seventeen patients developed regional failures, of which 16 were in-field; one patient showed an out-field failure in the parotid gland, and no recurrences were seen for level Ib. Failures in level II and in the retropharyngeal area accounted for 70.6% (12/17) and 52.9% (9/17) of all failures, respectively. The 5-year RFFS rates for patients with classifications of N0-1 and N2-3 were 98.5% and 90.2%, respectively (p = 0.001). Multivariate analysis showed that N stage was the only independent prognostic predictor of RFFS (HR 7.363, 95% CI 1.516-35.756, p = 0.013). Conclusions: The regional failure of NPC after treatment with IMRT is uncommon but is significantly higher in N2-3 patients than in N0-1 patients. In-field failures represent the main pattern of regional recurrence and are most often detected in level II and in the retropharyngeal area, while out-field failure is rare. Close attention should be directed to NPC patients with advanced N stages. PMID:28529611

  18. A Phase 1 Study of Everolimus + Weekly Cisplatin + Intensity Modulated Radiation Therapy in Head-and-Neck Cancer

    International Nuclear Information System (INIS)

    Fury, Matthew G.; Lee, Nancy Y.; Sherman, Eric; Ho, Alan L.; Rao, Shyam; Heguy, Adriana; Shen, Ronglai; Korte, Susan; Lisa, Donna; Ganly, Ian; Patel, Snehal; Wong, Richard J.; Shaha, Ashok; Shah, Jatin; Haque, Sofia; Katabi, Nora; Pfister, David G.

    2013-01-01

    Purpose: Elevated expression of eukaryotic protein synthesis initiation factor 4E (eIF4E) in histologically cancer-free margins of resected head and neck squamous cell carcinomas (HNSCCs) is mediated by mammalian target of rapamycin complex 1 (mTORC1) and has been associated with increased risk of disease recurrence. Preclinically, inhibition of mTORC1 with everolimus sensitizes cancer cells to cisplatin and radiation. Methods and Materials: This was single-institution phase 1 study to establish the maximum tolerated dose of daily everolimus given with fixed dose cisplatin (30 mg/m 2 weekly × 6) and concurrent intensity modulated radiation therapy for patients with locally and/or regionally advanced head-and-neck cancer. The study had a standard 3 + 3 dose-escalation design. Results: Tumor primary sites were oral cavity (4), salivary gland (4), oropharynx (2), nasopharynx (1), scalp (1), and neck node with occult primary (1). In 4 of 4 cases in which resected HNSCC surgical pathology specimens were available for immunohistochemistry, elevated expression of eIF4E was observed in the cancer-free margins. The most common grade ≥3 treatment-related adverse event was lymphopenia (92%), and dose-limiting toxicities (DLTs) were mucositis (n=2) and failure to thrive (n=1). With a median follow up of 19.4 months, 2 patients have experienced recurrent disease. The maximum tolerated dose was everolimus 5 mg/day. Conclusions: Head-and-neck cancer patients tolerated everolimus at therapeutic doses (5 mg/day) given with weekly cisplatin and intensity modulated radiation therapy. The regimen merits further evaluation, especially among patients who are status post resection of HNSCCs that harbor mTORC1-mediated activation of eIF4E in histologically negative surgical margins

  19. A Phase 1 Study of Everolimus + Weekly Cisplatin + Intensity Modulated Radiation Therapy in Head-and-Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Fury, Matthew G. [Department of Medicine, Head and Neck Oncology Service, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Medicine, Weill Cornell Medical College, New York, New York (United States); Lee, Nancy Y. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Sherman, Eric; Ho, Alan L. [Department of Medicine, Head and Neck Oncology Service, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Medicine, Weill Cornell Medical College, New York, New York (United States); Rao, Shyam [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Heguy, Adriana [Department of Human Oncology and Pathogenesis Program, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Shen, Ronglai [Department of Epidemiology and Biostatistics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Korte, Susan; Lisa, Donna [Department of Medicine, Head and Neck Oncology Service, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Ganly, Ian; Patel, Snehal; Wong, Richard J.; Shaha, Ashok; Shah, Jatin [Department of Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Haque, Sofia [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Katabi, Nora [Department of Pathology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Pfister, David G. [Department of Medicine, Head and Neck Oncology Service, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Medicine, Weill Cornell Medical College, New York, New York (United States)

    2013-11-01

    Purpose: Elevated expression of eukaryotic protein synthesis initiation factor 4E (eIF4E) in histologically cancer-free margins of resected head and neck squamous cell carcinomas (HNSCCs) is mediated by mammalian target of rapamycin complex 1 (mTORC1) and has been associated with increased risk of disease recurrence. Preclinically, inhibition of mTORC1 with everolimus sensitizes cancer cells to cisplatin and radiation. Methods and Materials: This was single-institution phase 1 study to establish the maximum tolerated dose of daily everolimus given with fixed dose cisplatin (30 mg/m{sup 2} weekly × 6) and concurrent intensity modulated radiation therapy for patients with locally and/or regionally advanced head-and-neck cancer. The study had a standard 3 + 3 dose-escalation design. Results: Tumor primary sites were oral cavity (4), salivary gland (4), oropharynx (2), nasopharynx (1), scalp (1), and neck node with occult primary (1). In 4 of 4 cases in which resected HNSCC surgical pathology specimens were available for immunohistochemistry, elevated expression of eIF4E was observed in the cancer-free margins. The most common grade ≥3 treatment-related adverse event was lymphopenia (92%), and dose-limiting toxicities (DLTs) were mucositis (n=2) and failure to thrive (n=1). With a median follow up of 19.4 months, 2 patients have experienced recurrent disease. The maximum tolerated dose was everolimus 5 mg/day. Conclusions: Head-and-neck cancer patients tolerated everolimus at therapeutic doses (5 mg/day) given with weekly cisplatin and intensity modulated radiation therapy. The regimen merits further evaluation, especially among patients who are status post resection of HNSCCs that harbor mTORC1-mediated activation of eIF4E in histologically negative surgical margins.

  20. The early adoption of intensity-modulated radiotherapy and stereotactic body radiation treatment among older Medicare beneficiaries with prostate cancer.

    Science.gov (United States)

    Jacobs, Bruce L; Yabes, Jonathan G; Lopa, Samia H; Heron, Dwight E; Chang, Chung-Chou H; Schroeck, Florian R; Bekelman, Justin E; Kahn, Jeremy M; Nelson, Joel B; Barnato, Amber E

    2017-08-01

    Several new prostate cancer treatments have emerged since 2000, including 2 radiotherapies with similar efficacy at the time of their introduction: intensity-modulated radiotherapy (IMRT) and stereotactic body radiation therapy (SBRT). The objectives of this study were to compare their early adoption patterns and identify factors associated with their use. By using the Surveillance, Epidemiology, and End Results (SEER)-Medicare database, patients who received radiation therapy during the 5 years after IMRT introduction (2001-2005) and the 5 years after SBRT introduction (2007-2011) were identified. The outcome of interest was the receipt of new radiation therapy (ie, IMRT or SBRT) compared with the existing standard radiation therapies at that time. The authors fit a series of multivariable, hierarchical logistic regression models accounting for patients nested within health service areas to examine the factors associated with the receipt of new radiation therapy. During 2001 to 2005, 5680 men (21%) received IMRT compared with standard radiation (n = 21,555). Men who received IMRT were older, had higher grade tumors, and lived in more populated areas (P adoption rate for IMRT was substantially higher than that for SBRT (44% vs 4%; P adoption rates of IMRT and SBRT at the time of their introduction. Further investigation of the nonclinical factors associated with this difference is warranted. Cancer 2017;123:2945-54. © 2017 American Cancer Society. © 2017 American Cancer Society.

  1. Dose to radiation therapists from activation at high-energy accelerators used for conventional and intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Rawlinson, J. Alan; Islam, Mohammad K.; Galbraith, Duncan M.

    2002-01-01

    The increased beam-on times which characterize intensity-modulated radiation therapy (IMRT) could lead to an increase in the dose received by radiation therapists due to induced activity. To examine this, gamma ray spectrometry was used to identify the major isotopes responsible for activation at a representative location in the treatment room of an 18 MV accelerator (Varian Clinac 21EX). These were found to be 28 Al, 56 Mn, and 24 Na. The decay of the dose rate measured at this location following irradiation was analyzed in terms of the known half-lives to yield saturation dose rates of 9.6, 12.4, and 6.2 μSv/h, respectively. A formalism was developed to estimate activation dose (μSv/week) due to successive patient irradiation cycles, characterized by the number of 18 MV fractions per week, F, the number of MU per fraction, M, the in-room time between fractions, t d (min), and the treatment delivery time t r ' (min). The results are represented by the sum of two formulas, one for the dose from 28 Al≅1.8x10 -3 F M (1-e -0.3t r ' )/t r ' and one for the dose from the other isotopes ≅1.1x10 -6 F 1.7 Mt d . For conventional therapy doses are about 60 μ Sv/week for an 18 MV workload of 60 000 MU/week. Irradiation for QA purposes can significantly increase the dose. For IMRT as currently practiced, lengthy treatment delivery times limit the number of fractions that can be delivered per week and hence limit the dose to values similar to those in conventional therapy. However for an IMRT regime designed to maximize patient throughput, doses up to 330 μSv/week could be expected. To reduce dose it is recommended that IMRT treatments should be delivered at energies lower than 18 MV, that in multienergy IMRT, high-energy treatments should be scheduled in the latter part of the day, and that equipment manufacturers should strive to minimize activation in the design of high-energy accelerators

  2. Optimization and quality assurance of an image-guided radiation therapy system for intensity-modulated radiation therapy radiotherapy

    International Nuclear Information System (INIS)

    Tsai, Jen-San; Micaily, Bizhan; Miyamoto, Curtis

    2012-01-01

    To develop a quality assurance (QA) of XVI cone beam system (XVIcbs) for its optimal imaging-guided radiotherapy (IGRT) implementation, and to construe prostate tumor margin required for intensity-modulated radiation therapy (IMRT) if IGRT is unavailable. XVIcbs spatial accuracy was explored with a humanoid phantom; isodose conformity to lesion target with a rice phantom housing a soap as target; image resolution with a diagnostic phantom; and exposure validation with a Radcal ion chamber. To optimize XVIcbs, rotation flexmap on coincidency between gantry rotational axis and that of XVI cone beam scan was investigated. Theoretic correlation to image quality of XVIcbs rotational axis stability was elaborately studied. Comprehensive QA of IGRT using XVIcbs has initially been explored and then implemented on our general IMRT treatments, and on special IMRT radiotherapies such as head and neck (H and N), stereotactic radiation therapy (SRT), stereotactic radiosurgery (SRS), and stereotactic body radiotherapy (SBRT). Fifteen examples of prostate setup accounted for 350 IGRT cone beam system were analyzed. IGRT accuracy results were in agreement ± 1 mm. Flexmap 0.25 mm met the manufacturer's specification. Films confirmed isodose coincidence with target (soap) via XVIcbs, otherwise not. Superficial doses were measured from 7.2–2.5 cGy for anatomic diameters 15–33 cm, respectively. Image quality was susceptible to rotational stability or patient movement. IGRT using XVIcbs on general IMRT treatments such as prostate, SRT, SRS, and SBRT for setup accuracy were verified; and subsequently coordinate shifts corrections were recorded. The 350 prostate IGRT coordinate shifts modeled to Gaussian distributions show central peaks deviated off the isocenter by 0.6 ± 3.0 mm, 0.5 ± 4.5 mm in the X(RL)- and Z(SI)-coordinates, respectively; and 2.0 ± 3.0 mm in the Y(AP)-coordinate as a result of belly and bladder capacity variations. Sixty-eight percent of confidence was within

  3. Target volume delineation and field setup. A practical guide for conformal and intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nancy Y. [Memorial Sloan-Kettering Cancer Center, New York, NY (United States). Radiation Oncology; Lu, Jiade J. (eds.) [National Univ. Health System, Singapore (Singapore). Dept. of Radiation Oncology; National Univ. of Singapore (Singapore). Dept. of Medicine

    2013-03-01

    Practical handbook on selection and delineation of tumor volumes and fields for conformal radiation therapy, including IMRT. Helpful format facilitating use on a step-by-step basis in daily practice. Designed to ensure accurate coverage of commonly encountered tumors along their routes of spread. This handbook is designed to enable radiation oncologists to appropriately and confidently delineate tumor volumes/fields for conformal radiation therapy, including intensity-modulated radiation therapy (IMRT), in patients with commonly encountered cancers. The orientation of this handbook is entirely practical, in that the focus is on the illustration of clinical target volume (CTV) delineation for each major malignancy. Each chapter provides guidelines and concise knowledge on CTV selection for a particular disease, explains how the anatomy of lymphatic drainage shapes the selection of the target volume, and presents detailed illustrations of volumes, slice by slice, on planning CT images. While the emphasis is on target volume delineation for three-dimensional conformal therapy and IMRT, information is also provided on conventional radiation therapy field setup and planning for certain malignancies for which IMRT is not currently suitable.

  4. Feasibility of a unified approach to intensity-modulated radiation therapy and volume-modulated arc therapy optimization and delivery

    International Nuclear Information System (INIS)

    Hoover, Douglas A.; Chen, Jeff Z.; MacFarlane, Michael; Wong, Eugene; Battista, Jerry J.

    2015-01-01

    Purpose: To study the feasibility of unified intensity-modulated arc therapy (UIMAT) which combines intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) optimization and delivery to produce superior radiation treatment plans, both in terms of dose distribution and efficiency of beam delivery when compared with either VMAT or IMRT alone. Methods: An inverse planning algorithm for UIMAT was prototyped within the PINNACLE treatment planning system (Philips Healthcare). The IMRT and VMAT deliveries are unified within the same arc, with IMRT being delivered at specific gantry angles within the arc. Optimized gantry angles for the IMRT and VMAT phases are assigned automatically by the inverse optimization algorithm. Optimization of the IMRT and VMAT phases is done simultaneously using a direct aperture optimization algorithm. Five treatment plans each for prostate, head and neck, and lung were generated using a unified optimization technique and compared with clinical IMRT or VMAT plans. Delivery verification was performed with an ArcCheck phantom (Sun Nuclear) on a Varian TrueBeam linear accelerator (Varian Medical Systems). Results: In this prototype implementation, the UIMAT plans offered the same target dose coverage while reducing mean doses to organs at risk by 8.4% for head-and-neck cases, 5.7% for lung cases, and 3.5% for prostate cases, compared with the VMAT or IMRT plans. In addition, UIMAT can be delivered with similar efficiency as VMAT. Conclusions: In this proof-of-concept work, a novel radiation therapy optimization and delivery technique that interlaces VMAT or IMRT delivery within the same arc has been demonstrated. Initial results show that unified VMAT/IMRT has the potential to be superior to either standard IMRT or VMAT

  5. Tomotherapy – a different way of dose delivery in radiotherapy

    Science.gov (United States)

    Skórska, Małgorzata; Jodda, Agata; Ryczkowski, Adam; Kaźmierska, Joanna; Adamska, Krystyna; Karczewska-Dzionk, Aldona; Żmijewska-Tomczak, Małgorzata; Włodarczyk, Hanna

    2012-01-01

    Aim of the study Helical tomotherapy is one of the methods of radiotherapy. This method enables treatment implementation for a wide spectrum of clinical cases. The vast array of therapeutic uses of helical tomotherapy results directly from the method of dose delivery, which is significantly different from the classic method developed for conventional linear accelerators. The paper discusses the method of dose delivery by a tomotherapy machine. Moreover, an analysis and presentation of treatment plans was performed in order to show the therapeutic possibilities of the applied technology. Dose distributions were obtained for anaplastic medulloblastoma, multifocal metastases to brain, vulva cancer, tongue cancer, metastases to bones, and advanced skin cancer. Tomotherapy treatment plans were compared with conventional linear accelerator plans. Results Following the comparative analysis of tomotherapy and conventional linear accelerator plans, in each case we obtained the increase in dose distribution conformity manifested in greater homogeneity of doses in the radiation target area for anaplastic medulloblastoma, multifocal metastases to brain, vulva cancer, metastases to bones, and advanced skin cancer, and the reduction of doses in organs at risk (OAR) for anaplastic medulloblastoma, vulva cancer, tongue cancer, and advanced skin cancer. The time of treatment delivery in the case of a tomotherapy machine is comparable to the implementation of the plan prepared in intensity-modulated radiotherapy (IMRT) technique for a conventional linear accelerator. In the case of tomotherapy the application of a fractional dose was carried out in each case during one working period of the machine. For a conventional linear accelerator the total value of the fractional dose in the case of anaplastic medulloblastoma and metastases to bones was delivered using several treatment plans, for which a change of set-up was necessary during a fraction. Conclusion The obtained results

  6. An algorithm for real-time dosimetry in intensity-modulated radiation therapy using the radioluminescence signal from Al2O3:C

    DEFF Research Database (Denmark)

    Andersen, C.E.; Marckmann, C.J.; Aznar, Marianne

    2006-01-01

    radiation beams. The dosimetry system has been used for dose measurements in a phantom during an intensity-modulated radiation therapy (IMRT) treatment with 6 MV photons. The RL measurement results are in excellent agreement (i.e. within 1%) with both the OSL results and the dose delivered according...

  7. Intensity modulated radiation therapy for squamous cell carcinoma of the vulva: Treatment technique and outcomes

    Directory of Open Access Journals (Sweden)

    Yuan James Rao, MD

    2017-04-01

    Conclusions: IMRT for vulvar cancer is associated with high rates of LRC in the postoperative setting and limited radiation-related toxicity. Durable LRC of disease after definitive IMRT remains challenging, and several refinements to our treatment technique are suggested.

  8. A novel software and conceptual design of the hardware platform for intensity modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Dan; Ruan, Dan; O’Connor, Daniel; Woods, Kaley; Low, Daniel A.; Sheng, Ke, E-mail: ksheng@mednet.ucla.edu [Department of Radiation Oncology, University of California, Los Angeles, Los Angeles, California 90024 (United States); Boucher, Salime [RadiaBeam Technologies, Santa Monica, California 90404 (United States)

    2016-02-15

    Purpose: To deliver high quality intensity modulated radiotherapy (IMRT) using a novel generalized sparse orthogonal collimators (SOCs), the authors introduce a novel direct aperture optimization (DAO) approach based on discrete rectangular representation. Methods: A total of seven patients—two glioblastoma multiforme, three head & neck (including one with three prescription doses), and two lung—were included. 20 noncoplanar beams were selected using a column generation and pricing optimization method. The SOC is a generalized conventional orthogonal collimators with N leaves in each collimator bank, where N = 1, 2, or 4. SOC degenerates to conventional jaws when N = 1. For SOC-based IMRT, rectangular aperture optimization (RAO) was performed to optimize the fluence maps using rectangular representation, producing fluence maps that can be directly converted into a set of deliverable rectangular apertures. In order to optimize the dose distribution and minimize the number of apertures used, the overall objective was formulated to incorporate an L2 penalty reflecting the difference between the prescription and the projected doses, and an L1 sparsity regularization term to encourage a low number of nonzero rectangular basis coefficients. The optimization problem was solved using the Chambolle–Pock algorithm, a first-order primal–dual algorithm. Performance of RAO was compared to conventional two-step IMRT optimization including fluence map optimization and direct stratification for multileaf collimator (MLC) segmentation (DMS) using the same number of segments. For the RAO plans, segment travel time for SOC delivery was evaluated for the N = 1, N = 2, and N = 4 SOC designs to characterize the improvement in delivery efficiency as a function of N. Results: Comparable PTV dose homogeneity and coverage were observed between the RAO and the DMS plans. The RAO plans were slightly superior to the DMS plans in sparing critical structures. On average, the maximum and

  9. A novel software and conceptual design of the hardware platform for intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Nguyen, Dan; Ruan, Dan; O’Connor, Daniel; Woods, Kaley; Low, Daniel A.; Sheng, Ke; Boucher, Salime

    2016-01-01

    Purpose: To deliver high quality intensity modulated radiotherapy (IMRT) using a novel generalized sparse orthogonal collimators (SOCs), the authors introduce a novel direct aperture optimization (DAO) approach based on discrete rectangular representation. Methods: A total of seven patients—two glioblastoma multiforme, three head & neck (including one with three prescription doses), and two lung—were included. 20 noncoplanar beams were selected using a column generation and pricing optimization method. The SOC is a generalized conventional orthogonal collimators with N leaves in each collimator bank, where N = 1, 2, or 4. SOC degenerates to conventional jaws when N = 1. For SOC-based IMRT, rectangular aperture optimization (RAO) was performed to optimize the fluence maps using rectangular representation, producing fluence maps that can be directly converted into a set of deliverable rectangular apertures. In order to optimize the dose distribution and minimize the number of apertures used, the overall objective was formulated to incorporate an L2 penalty reflecting the difference between the prescription and the projected doses, and an L1 sparsity regularization term to encourage a low number of nonzero rectangular basis coefficients. The optimization problem was solved using the Chambolle–Pock algorithm, a first-order primal–dual algorithm. Performance of RAO was compared to conventional two-step IMRT optimization including fluence map optimization and direct stratification for multileaf collimator (MLC) segmentation (DMS) using the same number of segments. For the RAO plans, segment travel time for SOC delivery was evaluated for the N = 1, N = 2, and N = 4 SOC designs to characterize the improvement in delivery efficiency as a function of N. Results: Comparable PTV dose homogeneity and coverage were observed between the RAO and the DMS plans. The RAO plans were slightly superior to the DMS plans in sparing critical structures. On average, the maximum and

  10. Radiation survey of first Hi-Art II Tomotherapy vault design in India

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A.; Jamema, S.V.; Pai, Rajeshree; Sharma, P.K. Dash; Deshpande, Deepak D.

    2009-01-01

    A vault as per government-regulation compliance with adequate shielding needs was designed and constructed for Hi-Art II Tomotherapy machine being the first in India. Radiation measurements around this Tomotherapy treatment vault were carried out to check the shielding adequacy of the source housing and the vault. It was mandatory to get this un-conventional machine 'Type Approved' by Atomic Energy Regulatory Board (AERB) in India. The aim of this paper was to report on the radiation levels measured during the radiation survey carried out for this machine. The radiation levels in and around the vault were measured for stationary as well as rotational treatment procedures with the largest open field size (5 cm x 40 cm) at the isocenter with and without scattering medium. The survey was performed at three locations near each wall surrounding the vault as well. The leakage radiation from the source housing was measured both in the patient plane outside the treatment field and one meter distance from the source outside the patient plane. The radiation levels both for stationary as well as rotational procedures were within 1 mR/h. No significance difference was observed in the radiation levels measured for rotational procedures with and without scattering medium. The leakage radiation in the patient plane was found to be 0.04% (Tolerance 0.2%), while the head leakage was 0.007% (Tolerance 0.5%) of the dose rate at the isocenter. The treatment delivery with Tomotherapy does play safe radiation levels around the installation layout and also passes the leakage criteria as well.

  11. Minimizing the number of segments in a delivery sequence for intensity-modulated radiation therapy with a multileaf collimator

    International Nuclear Information System (INIS)

    Dai Jianrong; Zhu Yunping

    2001-01-01

    This paper proposes a sequencing algorithm for intensity-modulated radiation therapy with a multileaf collimator in the static mode. The algorithm aims to minimize the number of segments in a delivery sequence. For a machine with a long verification and recording overhead time (e.g., 15 s per segment), minimizing the number of segments is equivalent to minimizing the delivery time. The proposed new algorithm is based on checking numerous candidates for a segment and selecting the candidate that results in a residual intensity matrix with the least complexity. When there is more than one candidate resulting in the same complexity, the candidate with the largest size is selected. The complexity of an intensity matrix is measured in the new algorithm in terms of the number of segments in the delivery sequence obtained by using a published algorithm. The beam delivery efficiency of the proposed algorithm and the influence of different published algorithms used to calculate the complexity of an intensity matrix were tested with clinical intensity-modulated beams. The results show that no matter which published algorithm is used to calculate the complexity of an intensity matrix, the sequence generated by the algorithm proposed here is always more efficient than that generated by the published algorithm itself. The results also show that the algorithm used to calculate the complexity of an intensity matrix affects the efficiency of beam delivery. The delivery sequences are frequently most efficient when the algorithm of Bortfeld et al. is used to calculate the complexity of an intensity matrix. Because no single variation is most efficient for all beams tested, we suggest implementing multiple variations of our algorithm

  12. Comparison of acute and subacute genitourinary and gastrointestinal adverse events of radiotherapy for prostate cancer using intensity-modulated radiation therapy, three-dimensional conformal radiation therapy, permanent implant brachytherapy and high-dose-rate brachytherapy

    NARCIS (Netherlands)

    Morimoto, Masahiro; Yoshioka, Yasuo; Konishi, Koji; Isohashi, Fumiaki; Takahashi, Yutaka; Ogata, Toshiyuki; Koizumi, Masahiko; Teshima, Teruki; Bijl, Henk P; van der Schaaf, Arjen; Langendijk, Johannes A; Ogawa, Kazuhiko

    2014-01-01

    AIMS AND BACKGROUND: To examine acute and subacute urinary and rectal toxicity in patients with localized prostate cancer monotherapeutically treated with the following four radiotherapeutic techniques: intensity-modulated radiation therapy, three-dimensional conformal radiation therapy,

  13. Radiobiological evaluation of intensity modulated radiation therapy treatments of patients with head and neck cancer: A dual-institutional study.

    Science.gov (United States)

    Narayanasamy, G; Pyakuryal, A P; Pandit, S; Vincent, J; Lee, C; Mavroidis, P; Papanikolaou, N; Kudrimoti, M; Sio, T T

    2015-01-01

    In clinical practice, evaluation of clinical efficacy of treatment planning stems from the radiation oncologist's experience in accurately targeting tumors, while keeping minimal toxicity to various organs at risk (OAR) involved. A more objective, quantitative method may be raised by using radiobiological models. The purpose of this work is to evaluate the potential correlation of OAR-related toxicities to its radiobiologically estimated parameters in simultaneously integrated boost (SIB) intensity modulated radiation therapy (IMRT) plans of patients with head and neck tumors at two institutions. Lyman model for normal tissue complication probability (NTCP) and the Poisson model for tumor control probability (TCP) models were used in the Histogram Analysis in Radiation Therapy (HART) analysis. In this study, 33 patients with oropharyngeal primaries in the head and neck region were used to establish the correlation between NTCP values of (a) bilateral parotids with clinically observed rates of xerostomia, (b) esophagus with dysphagia, and (c) larynx with dysphagia. The results of the study indicated a strong correlation between the severity of xerostomia and dysphagia with Lyman NTCP of bilateral parotids and esophagus, respectively, but not with the larynx. In patients without complications, NTCP values of these organs were negligible. Using appropriate radiobiological models, the presence of a moderate to strong correlation between the severities of complications with NTCP of selected OARs suggested that the clinical outcome could be estimated prior to treatment.

  14. Long-term results of forward intensity-modulated radiation therapy for patients with early-stage breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Boram; Suh, Hyun Suk; Lee, Ji Hae; Lee, Kyung Ja; Lee, Rena; Moon, Byung In [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    2013-12-15

    To observe long-term clinical outcomes for patients with early-stage breast cancer treated with forward intensity-modulated radiation therapy (IMRT), including local control and clinical toxicities. We retrospectively analyzed a total of 214 patients with stage I-II breast cancer who were treated with breast conserving surgery followed by adjuvant breast radiation therapy between 2001 and 2008. All patients were treated using forward IMRT. The whole breast was irradiated to a dose of 50 to 50.4 Gy followed by an 8 to 12 Gy electron boost to the surgical bed. The median age was 46 years (range, 21 to 82 years) and the medial follow-up time was 7.3 years (range, 2.4 to 11.7 years). Stage T1 was 139 (65%) and T2 was 75 (35%), respectively. Ipsilateral breast recurrence was observed in 3 patients. The 5- and 10-year local control rates were 99.1% and 97.8%, respectively. The cosmetic outcome was evaluated according to the Harvard scale and 89.4% of patients were scored as excellent or good. The whole breast radiation therapy as an adjuvant treatment using a forward IMRT technique showed excellent long-term local control as well as favorable outcomes of toxicity and cosmesis.

  15. Treatment with intensity-modulated radiation therapy (IMRT) for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Marta, G.N.; Hanna, S.A.; Gadia, R.

    2014-11-15

    Through the development of four relevant clinical questions related with the proposed subject, we tried to present the main evidence for safety, toxicity and effectiveness using different radiotherapy techniques. The study population consisted of female patients of all ages with primary breast cancer treated with radiation therapy to the whole breast, regardless of histological type, staging, context of treatment (radical, adjuvant or palliative) and whether comorbidities were present or not. For this, a systematic review of the literature was performed in primary scientific research databases (Medline - Pubmed; Embase - Elsevier; Lilacs - Bireme; Cochrane Library - Central Register of Controlled Trials). All articles available until July 22, 2013, were included. The search strategy used for Medline research is described in Appendix. Articles were selected based on critical evaluation in search of the best available evidence. Recommendations were prepared based on discussion with the writing group, composed of three members of the Brazilian Society of Radiotherapy. The guideline was reviewed by an independent group specializing in evidence-based clinical guidelines. After completion, the guideline was made available for public consultation for 15 days and the suggestions forwarded to the writers for evaluation and consideration into the final text. Objective: to assess the most appropriate method of radiation therapy for treating patients with primary breast tumors. (author)

  16. Prospective Study of Functional Bone Marrow-Sparing Intensity Modulated Radiation Therapy With Concurrent Chemotherapy for Pelvic Malignancies

    International Nuclear Information System (INIS)

    Liang Yun; Bydder, Mark; Yashar, Catheryn M.; Rose, Brent S.; Cornell, Mariel; Hoh, Carl K.; Lawson, Joshua D.; Einck, John; Saenz, Cheryl; Fanta, Paul; Mundt, Arno J.; Bydder, Graeme M.

    2013-01-01

    Purpose: To test the hypothesis that intensity modulated radiation therapy (IMRT) can reduce radiation dose to functional bone marrow (BM) in patients with pelvic malignancies (phase IA) and estimate the clinical feasibility and acute toxicity associated with this technique (phase IB). Methods and Materials: We enrolled 31 subjects (19 with gynecologic cancer and 12 with anal cancer) in an institutional review board-approved prospective trial (6 in the pilot study, 10 in phase IA, and 15 in phase IB). The mean age was 52 years; 8 of 31 patients (26%) were men. Twenty-one subjects completed 18 F-fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) simulation and magnetic resonance imaging by use of quantitative IDEAL (IDEAL IQ; GE Healthcare, Waukesha, WI). The PET/CT and IDEAL IQ were registered, and BM subvolumes were segmented above the mean standardized uptake value and below the mean fat fraction within the pelvis and lumbar spine; their intersection was designated as functional BM for IMRT planning. Functional BM-sparing vs total BM-sparing IMRT plans were compared in 12 subjects; 10 were treated with functional BM-sparing pelvic IMRT per protocol. Results: In gynecologic cancer patients, the mean functional BM V 10 (volume receiving ≥10 Gy) and V 20 (volume receiving ≥20 Gy) were 85% vs 94% (P 18 F-fluorodeoxyglucose-PET/CT and IDEAL IQ. The efficacy of BM-sparing IMRT is being tested in a phase II trial.

  17. Secondary radiation doses of intensity-modulated radiotherapy and proton beam therapy in patients with lung and liver cancer.

    Science.gov (United States)

    Kim, Seonkyu; Min, Byung Jun; Yoon, Myonggeun; Kim, Jinsung; Shin, Dong Ho; Lee, Se Byeong; Park, Sung Yong; Cho, Sungkoo; Kim, Dae Hyun

    2011-03-01

    To compare the secondary radiation doses following intensity-modulated radiotherapy (IMRT) and proton beam therapy (PBT) in patients with lung and liver cancer. IMRT and PBT were planned for three lung cancer and three liver cancer patients. The treatment beams were delivered to phantoms and the corresponding secondary doses during irradiation were measured at various points 20-50 cm from the beam isocenter using ion chamber and CR-39 detectors for IMRT and PBT, respectively. The secondary dose per Gy (i.e., a treatment dose of 1Gy) from PBT for lung and liver cancer, measured 20-50 cm from the isocenter, ranged from 0.17 to 0.086 mGy. The secondary dose per Gy from IMRT, however, ranged between 5.8 and 1.0 mGy, indicating that PBT is associated with a smaller dose of secondary radiation than IMRT. The internal neutron dose per Gy from PBT for lung and liver cancer, 20-50 cm from the isocenter, ranged from 0.03 to 0.008 mGy. The secondary dose from PBT is less than or compatible to the secondary dose from conventional IMRT. The internal neutron dose generated by the interaction between protons and body material is generally much less than the external neutron dose from the treatment head. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  18. Development and evaluation of a phantom for multi-purpose dosimetry in intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hae Sun; Kim, Chan Hyeong [Hanyang University, Seoul (Korea, Republic of); Park, Joo Hwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Han, Young Yih [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kum, O Yeon [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2011-08-15

    A LEGO-type multi-purpose dosimetry phantom was developed for intensity-modulated radiation therapy (IMRT), which requires various types of challenging dosimetry. Polystyrene, polyethylene, polytetrafluoroethylene (PTFE), and polyurethane foam (PU-F) were selected to represent muscle, fat, bone, and lung tissue, respectively, after considering the relevant mass densities, elemental compositions, effective atomic numbers, and photon interaction coefficients. The phantom, which is composed of numerous small pieces that are similar to LEGO blocks, provides dose and dose distribution measurements in homogeneous and heterogeneous media. The phantom includes dosimeter holders for several types of dosimeters that are frequently used in IMRT dosimetry. An ion chamber and a diode detector were used to test dosimetry in heterogeneous media under radiation fields of various sizes. The data that were measured using these dosimeters were in disagreement when the field sizes were smaller than 1.5 x 1.5 cm{sup 2} for polystyrene and PTFE, or smaller than 3 x 3 cm{sup 2} for an air cavity. The discrepancy was as large as 41% for the air cavity when the field size was 0.7 x 0.7 cm{sup 2}, highlighting one of the challenges of IMRT small field dosimetry. The LEGO-type phantom is also very useful for two-dimensional dosimetry analysis, which elucidates the electronic dis-equilibrium phenomena on or near the heterogeneity boundaries

  19. Skin dose for head and neck cancer patients treated with intensity-modulated radiation therapy(IMRT)

    Science.gov (United States)

    Fu, Hsiao-Ju; Li, Chi-Wei; Tsai, Wei-Ta; Chang, Chih-Chia; Tsang, Yuk-Wah

    2017-11-01

    The reliability of thermoluminescent dosimeters (ultrathin TLD) and ISP Gafchromic EBT2 film to measure the surface dose in phantom and the skin dose in head-and-neck patients treated with intensity-modulated radiation therapy technique(IMRT) is the research focus. Seven-field treatment plans with prescribed dose of 180 cGy were performed on Eclipse treatment planning system which utilized pencil beam calculation algorithm(PBC). In calibration tests, the variance coefficient of the ultrathin TLDs were within 3%. The points on the calibration curve of the Gafchromic film was within 1% variation. Five measurements were taken on phantom using ultrathin TLD and EBT2 film respectively. The measured mean surface doses between ultrathin TLD or EBT2 film were within 5% deviation. Skin doses of 6 patients were measured for initial 5 fractions and the mean dose per-fraction was calculated. If the extrapolated doses for 30 fractions were below 4000 cGy, the skin reaction grading observed according to Radiation Therapy Oncology Group (RTOG) was either grade 1 or grade 2. If surface dose exceeded 5000 cGy in 32 fractions, then grade 3 skin reactions were observed.

  20. Reproducible deep-inspiration breath-hold irradiation with forward intensity-modulated radiotherapy for left-sided breast cancer significantly reduces cardiac radiation exposure compared to inverse intensity-modulated radiotherapy.

    Science.gov (United States)

    Bolukbasi, Yasemin; Saglam, Yucel; Selek, Ugur; Topkan, Erkan; Kataria, Anglina; Unal, Zeynep; Alpan, Vildan

    2014-01-01

    isodose line of the proximal left anterior descending artery were 6.6 vs 3.3 cm and of the distal left anterior descending artery were 7.4 vs 4.1 cm, with forward intensity-modulated radiotherapy. Overall reduction in mean doses to proximal and distal left anterior descending artery with deep-inspiration breath-hold irradiation was 39% (P = 0.02) and 52% (P = 0.002), respectively. We found a significant reduction of radiation exposure to the contralateral breast, left and right ventricles, as well as of proximal and especially distal left anterior descending artery with the deep-inspiration breath-hold technique with forward intensity-modulated radiotherapy planning.

  1. Influence of the SURLAS applicator on radiation dose distributions during simultaneous thermoradiotherapy with helical tomotherapy

    International Nuclear Information System (INIS)

    Novak, Petr; PenagarIcano, Jose A; Nahirnyak, Volodymyr; Corry, Peter; Moros, Eduardo G

    2008-01-01

    Simultaneous thermoradiotherapy has been shown to maximize the effect of hyperthermia as a radiation sensitizer in cancer treatment. Here we follow our previous work on feasibility of thermoradiotherapy with the scanning ultrasound reflector linear array system (SURLAS) and TomoTherapy (registered) Hi.Art (registered) treatment system, and investigate the influence of the SURLAS hyperthermia applicator on delivered radiation dose with the TomoTherapy. A radiation treatment plan was calculated and the treatment was delivered to a phantom with SURLAS on top simulating the likely clinical setup. Proper positioning of the SURLAS was assisted with a magnetic position-and-orientation tracking device (POTD) and was verified with megavoltage-computed tomography. The delivered dose was measured with an ionization chamber (point measurement) and a radiographic film (2D dose distributions). The planned and delivered point dose data agreed within 0.61% ± 0.63%. Planar dose data agreed within a dose difference of ≤3% of the maximum dose, and a distance-to-dose-agreement of ≤1 mm. The susceptibility of the delivered radiation dose on correct SURLAS positioning was studied as well. The largest dose discrepancy was measured for a position for which a maximum number of radiation beams intersected the incorrectly positioned SURLAS within one TomoTherapy gantry rotation. The point dose disagreed by 6.14% ± 0.52%, and 2.25% of pixels of the 2D dose distribution did not pass the 3% dose difference/1 mm distance-to-dose-agreement criteria. Our study showed that correct positioning of the SURLAS applicator had an influence on the delivered radiation dose. Delivered and planned dose distributions were in an excellent agreement when SURLAS was positioned according to the treatment plan. Moving the applicator from its planned position was found to cause a modification of delivered dose distributions. A precise and reproducible positioning of the applicator was assured with a POTD

  2. Osteoradionecrosis of the mandible. Minimized risk profile following Intensity-Modulated Radiation Therapy (IMRT)

    International Nuclear Information System (INIS)

    Studer, G.; Huguenin, P.; Luetolf, U.M.; Glanzmann, C.; Studer, S.P.; Zwahlen, R.A.; Graetz, K.W.

    2006-01-01

    Background and purpose: osteoradionecrosis (ON) of the mandible is a serious late complication of high-dose radiation therapy for tumors of the oropharynx and oral cavity. After doses between 60 and 72 Gy using standard fractionation, an incidence of ON between 5% and 15% is reported in a review from 1989, whereas in more recent publications using moderately accelerated or hyperfractionated irradiation and doses between 69 and 81 Gy, the incidence of ON is between 60 Gy for oropharyngeal or oral cavity cancer). 21/73 patients were treated in a postoperative setting, 52 patients underwent primary definitive irradiation. In 56 patients concomitant cisplatin-based chemotherapy was applied. Mean follow-up time was 22 months (12-46 months). Oral cavity including the mandible bone outside the planning target volume was contoured and dose-volume constraints were defined in order to spare bone tissue. Dose-volume histograms were obtained from contoured mandible in each patient and were analyzed and related to clinical mandible bone tolerance. Results: using IMRT with doses between 60 and 75 Gy (mean 67 Gy), on average 7.8, 4.8, 0.9, and 0.3 cm 3 were exposed to doses > 60, 65, 70, and 75 Gy, respectively. These values are substantially lower than when using three-dimensional conformal radiotherapy. The difference has been approximately quantified by comparison with a historic series. Additional ON risk factors of the patients were also analyzed. Only one grade 3 ON of the lingual horizontal branch, treated with lingual decortication, was observed. Conclusion: using IMRT, only very small partial volumes of the mandibular bone are exposed to high radiation doses. This is expected to translate into a further reduction of ON and improved osseointegration of dental implants. (orig.)

  3. Intensity-modulated radiotherapy for cancers in childhood

    International Nuclear Information System (INIS)

    Leseur, J.; Le Prise, E.; Leseur, J.; Carrie, C.; Beneyton, V.; Bernier, V.; Beneyton, V.; Mahee, M.A.; Supiot, S.

    2009-01-01

    Approximately 40-50% of children with cancer will be irradiated during their treatment. Intensity-modulated radiotherapy (I.M.R.T.) by linear accelerator or helical tomo-therapy improves dose distribution in target volumes and normal tissue sparing. This technology could be particularly useful for pediatric patients to achieve an optimal dose distribution in complex volumes close to critical structures. The use of I.M.R.T. can increase the volume of tissue receiving low-dose radiation, and consequently carcinogenicity in childhood population with a good overall survival and long period of life expectancy. This review will present the current and potential I.M.R.T. indications for cancers in childhood, and discuss the benefits and problems of this technology aiming to define recommendations in the use of I.M.R.T. and specific doses constraints in Pediatrics. (authors)

  4. Concurrent chemotherapy with intensity-modulated radiation therapy for locally advanced squamous cell carcinoma of the larynx and oropharynx: A retrospective single-institution analysis

    NARCIS (Netherlands)

    N.F. Saba (Nabil); D.J. Edelman (David); M. Tighiouart (Mourad); J.G. Gaultney (Jennifer G.); L.W. Davis (Lawrence); F.R. Khuri (Fadlo); A. Chen (Amy); S. Grist (Scott); D.M. Shin (Dong)

    2009-01-01

    textabstractBackground. We present outcome data from concurrent chemotherapy and intensity-modulated radiation therapy (IMRT) for squamous cell carcinoma (SCC) of the larynx and oropharyx. Methods. Eighty patients with laryngeal (n = 15) or oropharyngeal (n = 65) SCC underwent concurrent IMRT and

  5. Late toxicity after intensity modulated and image guided radiation therapy for localized prostate cancer and post-prostatectomy patients.

    Science.gov (United States)

    Hunter, Grant K; Brockway, Kristin; Reddy, Chandana A; Rehman, Sana; Sheplan, Lawrence J; Stephans, Kevin L; Ciezki, Jay P; Xia, Ping; Tendulkar, Rahul D

    2013-01-01

    To examine late gastrointestinal (GI) and genitourinary (GU) toxicity profiles of patients treated for prostate cancer either definitively or post-prostatectomy with both intensity modulated radiation therapy (IMRT) and image guided radiation therapy (IGRT). A total of 333 patients treated definitively and 104 patients treated postoperatively with IMRT and varying IGRT techniques were retrospectively examined to evaluate GI and GU toxicity profiles >1 year from treatment. Available dosimetric data were used for correlative analysis. The median follow-up time for the definitive patients was 41 months and the median follow-up time for the post-prostatectomy patients was 33 months. No late grade 4 or 5 GI or GU toxicities were observed. For definitive patients, the rates of grade ≥2 GI and GU toxicity at 3 years were 4.9% and 4.5%, respectively. In the postoperative cohort the rate of grade >2 GU toxicity was 11.6%, with no grade ≥2 GI toxicity. In the definitive cohort's Cox proportional hazards regression univariate analysis, use of anticoagulation was significantly associated with GI toxicity and age, bladder V50 and IGRT modality were associated with GU toxicity, and only age remained significant in the multivariate model. In univariate analysis for the postoperative cohort, no dosimetric value correlated with GU toxicity, nor did age or time from radical prostatectomy to radiation. IMRT with IGRT achieved low rates of GI and GU toxicity in the definitive and postoperative setting. Copyright © 2013 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  6. Is "pelvic radiation disease" always the cause of bowel symptoms following prostate cancer intensity-modulated radiotherapy?

    Science.gov (United States)

    Min, Myo; Chua, Benjamin; Guttner, Yvonne; Abraham, Ned; Aherne, Noel J; Hoffmann, Matthew; McKay, Michael J; Shakespeare, Thomas P

    2014-02-01

    Pelvic radiation disease (PRD) also widely known as "radiation proctopathy" is a well recognised late side-effect following conventional prostate radiotherapy. However, endoscopic evaluation and/or specialist referral for new or persistent post-prostate radiotherapy bowel symptoms is not routine and serious diagnoses may potentially be missed. Here we report a policy of endoscopic evaluation of bowel symptoms persisting >90 days post radiotherapy for prostate cancer. A consecutive series of 102 patients who had radical prostate intensity-modulated radiotherapy (IMRT)/image-guided radiotherapy (IGRT) and who had new or ongoing bowel symptoms or positive faecal occult blood tests (FOBT) on follow up visits more than three months after treatment, were referred for endoscopic examination. All but one (99%) had full colonoscopic investigation. Endoscopic findings included gastric/colonic/rectal polyps (56%), diverticular disease (49%), haemorrhoids (38%), radiation proctopathy (29%), gastritis/oesophagitis (8%) and rarer diagnoses, including bowel cancer which was found in 3%. Only four patients (4%) had radiation proctopathy without associated pathology and 65 patients (63%) had more than one diagnosis. If flexible sigmoidoscopy alone were used, 36.6% of patients and 46.6% patients with polyp(s) would have had their diagnoses missed. Our study has shown that bowel symptoms following prostate IMRT/IGRT are due to numerous diagnoses other than PRD, including malignancy. Routine referral pathways should be developed for endoscopic evaluation/specialist review for patients with new or persistent bowel symptoms (or positive FOBT) following prostate radiotherapy. This recommendation should be considered for incorporation into national guidelines. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. Is “pelvic radiation disease” always the cause of bowel symptoms following prostate cancer intensity-modulated radiotherapy?

    International Nuclear Information System (INIS)

    Min, Myo; Chua, Benjamin; Guttner, Yvonne; Abraham, Ned; Aherne, Noel J.; Hoffmann, Matthew; McKay, Michael J.; Shakespeare, Thomas P.

    2014-01-01

    Background: Pelvic radiation disease (PRD) also widely known as “radiation proctopathy” is a well recognised late side-effect following conventional prostate radiotherapy. However, endoscopic evaluation and/or specialist referral for new or persistent post-prostate radiotherapy bowel symptoms is not routine and serious diagnoses may potentially be missed. Here we report a policy of endoscopic evaluation of bowel symptoms persisting >90 days post radiotherapy for prostate cancer. Methods and materials: A consecutive series of 102 patients who had radical prostate intensity-modulated radiotherapy (IMRT)/image-guided radiotherapy (IGRT) and who had new or ongoing bowel symptoms or positive faecal occult blood tests (FOBT) on follow up visits more than three months after treatment, were referred for endoscopic examination. All but one (99%) had full colonoscopic investigation. Results: Endoscopic findings included gastric/colonic/rectal polyps (56%), diverticular disease (49%), haemorrhoids (38%), radiation proctopathy (29%), gastritis/oesophagitis (8%) and rarer diagnoses, including bowel cancer which was found in 3%. Only four patients (4%) had radiation proctopathy without associated pathology and 65 patients (63%) had more than one diagnosis. If flexible sigmoidoscopy alone were used, 36.6% of patients and 46.6% patients with polyp(s) would have had their diagnoses missed. Conclusions: Our study has shown that bowel symptoms following prostate IMRT/IGRT are due to numerous diagnoses other than PRD, including malignancy. Routine referral pathways should be developed for endoscopic evaluation/specialist review for patients with new or persistent bowel symptoms (or positive FOBT) following prostate radiotherapy. This recommendation should be considered for incorporation into national guidelines

  8. A statistical quantification of radiobiological metrics in Intensity Modulated Radiation Therapy evaluation.

    Science.gov (United States)

    Surega, A; Punitha, J; Sajitha, S; Ramesh, Bs; Pichandi, A; Sasikala, P

    2015-01-01

    The dosimetric parameters from the DVH cannot predict the amount of tumor kill and normal tissue complications directly but it can assess the conformity and homogeneity of the physical dose distributions. For example, the D-V parameter V20 (Percentage of lung volume receiving 20Gy) is used to gauge the incidence of grade =2 or grade =3 radiation pneumonitis with the plan. But the complication can be correlated to more than one point in the DVH (eg. V5, V40, D50) and it is treatment technique dependent. The aim of this study is to quantify the uncertainty of physical dose metrics to predict the clinical outcomes of the radiotherapy treatments. The radiobiological estimates such as TCP and NTCP were made for a cohort of 50 patients (15-Brain; 20-H and N; 15-Pelvis) using the D-V parameters. A statistical analysis based on Spearman ranking coefficient correlation was performed to determine the correlation of the physical plan quality indicators with that of radiobiological estimates. The correlation between the Conformity Index and the Tumor Control probability was found to be good and the dosimetric parameters for optic nerves, optic chiasm, brain stem, normal brain and parotids correlated well with the Normal Tissue Complication Probability estimates compared to other normal structures. A follow up study (median duration: 28 Months) was also performed. There was no grade 3 or grade 4 normal tissue complications observed. Local tumor control was found to be higher in brain (90%) and pelvic cases (95%) whereas a decline of 75% was noted with Head and Neck cases. The EUD concept of radiobiological model used in the software determines the TCP and NTCP values which can predict precise outcomes with the use of dose volume data in the voxel level. The uncertainty of using physical dose metrics for plan evaluation is quantified with the statistical analysis. It is also helpful in ranking rival treatment plans.

  9. Out-of-Field Cell Survival Following Exposure to Intensity-Modulated Radiation Fields

    International Nuclear Information System (INIS)

    Butterworth, Karl T.; McGarry, Conor K.; Trainor, Colman; O'Sullivan, Joe M.; Hounsell, Alan R.; Prise, Kevin M.

    2011-01-01

    Purpose: To determine the in-field and out-of-field cell survival of cells irradiated with either primary field or scattered radiation in the presence and absence of intercellular communication. Methods and Materials: Cell survival was determined by clonogenic assay in human prostate cancer (DU145) and primary fibroblast (AGO1552) cells following exposure to different field configurations delivered using a 6-MV photon beam produced with a Varian linear accelerator. Results: Nonuniform dose distributions were delivered using a multileaf collimator (MLC) in which half of the cell population was shielded. Clonogenic survival in the shielded region was significantly lower than that predicted from the linear quadratic model. In both cell lines, the out-of-field responses appeared to saturate at 40%-50% survival at a scattered dose of 0.70 Gy in DU-145 cells and 0.24 Gy in AGO1522 cells. There was an approximately eightfold difference in the initial slopes of the out-of-field response compared with the α-component of the uniform field response. In contrast, cells in the exposed part of the field showed increased survival. These observations were abrogated by direct physical inhibition of cellular communication and by the addition of the inducible nitric oxide synthase inhibitor aminoguanidine known to inhibit intercellular bystander effects. Additional studies showed the proportion of cells irradiated and dose delivered to the shielded and exposed regions of the field to impact on response. Conclusions: These data demonstrate out-of-field effects as important determinants of cell survival following exposure to modulated irradiation fields with cellular communication between differentially irradiated cell populations playing an important role. Validation of these observations in additional cell models may facilitate the refinement of existing radiobiological models and the observations considered important determinants of cell survival.

  10. Risk Factors for Pelvic Insufficiency Fractures in Locally Advanced Cervical Cancer Following Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ramlov, Anne, E-mail: anraml@rm.dk [Department of Oncology, Aarhus University Hospital, Aarhus (Denmark); Pedersen, Erik Morre; Røhl, Lisbeth [Department of Radiotherapy, Aarhus University Hospital, Aarhus (Denmark); Worm, Esben [Department of Medical Physics, Aarhus University Hospital, Aarhus (Denmark); Fokdal, Lars; Lindegaard, Jacob Chr. [Department of Oncology, Aarhus University Hospital, Aarhus (Denmark); Tanderup, Kari [Department of Oncology, Aarhus University Hospital, Aarhus (Denmark); Department of Medical Physics, Aarhus University Hospital, Aarhus (Denmark)

    2017-04-01

    Purpose: To investigate the incidence of and risk factors for pelvic insufficiency fracture (PIF) after definitive chemoradiation therapy for locally advanced cervical cancer (LACC). Methods and Materials: We analyzed 101 patients with LACC treated from 2008-2014. Patients received weekly cisplatin and underwent external beam radiation therapy with 45 Gy in 25 fractions (node-negative patients) or 50 Gy in 25 fractions with a simultaneous integrated boost of 60 Gy in 30 fractions (node-positive patients). Pulsed dose rate magnetic resonance imaging guided adaptive brachytherapy was given in addition. Follow-up magnetic resonance imaging was performed routinely at 3 and 12 months after the end of treatment or based on clinical indication. PIF was defined as a fracture line with or without sclerotic changes in the pelvic bones. D{sub 50%} and V{sub 55Gy} were calculated for the os sacrum and jointly for the os ileum and pubis. Patient- and treatment-related factors including dose were analyzed for correlation with PIF. Results: The median follow-up period was 25 months. The median age was 50 years. In 20 patients (20%), a median of 2 PIFs (range, 1-3 PIFs) were diagnosed; half were asymptomatic. The majority of the fractures were located in the sacrum (77%). Age was a significant risk factor (P<.001), and the incidence of PIF was 4% and 37% in patients aged ≤50 years and patients aged >50 years, respectively. Sacrum D{sub 50%} was a significant risk factor in patients aged >50 years (P=.04), whereas V{sub 55Gy} of the sacrum and V{sub 55Gy} of the pelvic bones were insignificant (P=.33 and P=.18, respectively). A dose-effect curve for sacrum D{sub 50%} in patients aged >50 years showed that reduction of sacrum D{sub 50%} from 40 Gy{sub EQD2} to 35 Gy{sub EQD2} reduces PIF risk from 45% to 22%. Conclusions: PIF is common after treatment of LACC and is mainly seen in patients aged >50 years. Our data indicate that PIFs are not related to lymph node

  11. Comparison of conformal and intensity modulated radiation therapy techniques for treatment of pelvic tumors. Analysis of acute toxicity

    International Nuclear Information System (INIS)

    Ferrigno, Robson; Santos, Adriana; Martins, Lidiane C; Weltman, Eduardo; Chen, Michael J; Sakuraba, Roberto; Lopes, Cleverson P; Cruz, José C

    2010-01-01

    This retrospective analysis reports on the comparative outcome of acute gastrointestinal (GI) and genitourinary (GU) toxicities between conformal radiation therapy (CRT) and intensity modulated radiation therapy (IMRT) techniques in the treatment of patients with pelvic tumors. From January 2002 to December 2008, 69 patients with pelvic tumors underwent whole pelvic CRT and 65 underwent whole pelvic IMRT to treat pelvic lymph nodes and primary tumor regions. Total dose to the whole pelvis ranged from 50 to 50.4 Gy in 25 to 28 daily fractions. Chemotherapy (CT) regimen, when employed, was based upon primary tumor. Acute GI and GU toxicities were graded by RTOG/EORTC acute radiation morbidity criteria. Absence of GI symptoms during radiotherapy (grade 0) was more frequently observed in the IMRT group (43.1% versus 8.7; p < 0.001) and medication for diarrhea (Grade 2) was more frequently used in the CRT group (65.2% versus 38.5%; p = 0.002). Acute GI grade 1 and 3 side effects incidence was similar in both groups (18.5% versus 18.8%; p = 0.95 and 0% versus 7.2%; p = 0.058, respectively). Incidence of GU toxicity was similar in both groups (grade 0: 61.5% versus 66.6%, p = 0.54; grade 1: 20% versus 8.7%, p = 0.06; grade 2: 18.5% versus 23.5%, p = 0.50 and grade 3: 0% versus 1.5%, p > 0.99). This comparative case series shows less grade 2 acute GI toxicity in patients treated with whole pelvic IMRT in comparison with those treated with CRT. Incidence of acute GU toxicity was similar in both groups

  12. Convex reformulation of biologically-based multi-criteria intensity-modulated radiation therapy optimization including fractionation effects.

    Science.gov (United States)

    Hoffmann, Aswin L; den Hertog, Dick; Siem, Alex Y D; Kaanders, Johannes H A M; Huizenga, Henk

    2008-11-21

    Finding fluence maps for intensity-modulated radiation therapy (IMRT) can be formulated as a multi-criteria optimization problem for which Pareto optimal treatment plans exist. To account for the dose-per-fraction effect of fractionated IMRT, it is desirable to exploit radiobiological treatment plan evaluation criteria based on the linear-quadratic (LQ) cell survival model as a means to balance the radiation benefits and risks in terms of biologic response. Unfortunately, the LQ-model-based radiobiological criteria are nonconvex functions, which make the optimization problem hard to solve. We apply the framework proposed by Romeijn et al (2004 Phys. Med. Biol. 49 1991-2013) to find transformations of LQ-model-based radiobiological functions and establish conditions under which transformed functions result in equivalent convex criteria that do not change the set of Pareto optimal treatment plans. The functions analysed are: the LQ-Poisson-based model for tumour control probability (TCP) with and without inter-patient heterogeneity in radiation sensitivity, the LQ-Poisson-based relative seriality s-model for normal tissue complication probability (NTCP), the equivalent uniform dose (EUD) under the LQ-Poisson model and the fractionation-corrected Probit-based model for NTCP according to Lyman, Kutcher and Burman. These functions differ from those analysed before in that they cannot be decomposed into elementary EUD or generalized-EUD functions. In addition, we show that applying increasing and concave transformations to the convexified functions is beneficial for the piecewise approximation of the Pareto efficient frontier.

  13. A national survey of the availability of intensity-modulated radiation therapy and stereotactic radiosurgery in Canada

    Directory of Open Access Journals (Sweden)

    AlDuhaiby Eman Z

    2012-02-01

    Full Text Available Abstract Background The timely and appropriate adoption of new radiation therapy (RT technologies is a challenge both in terms of providing of optimal patient care and managing health care resources. Relatively little is known regarding the rate at which new RT technologies are adopted in different jurisdictions, and the barriers to implementation of these technologies. Methods Surveys were sent to all radiation oncology department heads in Canada regarding the availability of RT equipment from 2006 to 2010. Data were collected concerning the availability and use of Intensity Modulated Radiation Therapy (IMRT and stereotactic radiosurgery (SRS, and the obstacles to implementation of these technologies. Results IMRT was available in 37% of responding centers in 2006, increasing to 87% in 2010. In 2010, 72% of centers reported that IMRT was available for all patients who might benefit, and 37% indicated that they used IMRT for "virtually all" head and neck patients. SRS availability increased from 26% in 2006 to 42.5% in 2010. Eighty-two percent of centers reported that patients had access to SRS either directly or by referral. The main barriers for IMRT implementation included the need to train or hire treatment planning staff, whereas barriers to SRS implementation mostly included the need to purchase and/or upgrade existing planning software and equipment. Conclusions The survey showed a growing adoption of IMRT and SRS in Canada, although the latter was available in less than half of responding centers. Barriers to implementation differed for IMRT compared to SRS. Enhancing human resources is an important consideration in the implementation of new RT technologies, due to the multidisciplinary nature of the planning and treatment process.

  14. Intensity Modulated Radiation Therapy in Head and Neck Squamous Cell Carcinoma: state of the art and future challenges

    International Nuclear Information System (INIS)

    Gregoire, V.; Maingon, P.

    2005-01-01

    Intensity-modulated radiation therapy (IMRT) for head and neck (HN) tumors refers to a new approach to the whole treatment procedure from patient immobilization to beam delivery. Implementation of IMRT thus requires knowledge of setup uncertainties, adequate selection and delineation of target volumes based on clinical examination and optimal imaging modalities, appropriate specification and dose prescription regarding dose-volume constraints, and ad hoc quality control of both the clinical and physical aspects of the whole procedure. A large number of issues still need to be resolved and/or further refined, such as the optimal selection and delineation of the target volume in particular, with the introduction of functional imaging, and a better integration of improved dose distribution into the fractionation strategy. IMRT is associated with a potentially increased incidence of carcinogenesis, although in the HN area this risk is relative to the intrinsic risk of co-morbidity and secondary cancer associated with the patient's lifestyle. Currently, the implementation of IMRT into routine clinical practice for HN cancers may not be a straightforward matter, and should probably be restricted to selected patients and selected institutions with adequate resources and experience. This review emphasizes the above aspects and provides some recommendations for the future use of IMRT in patients with HN tumors. (author)

  15. 3D radiation therapy or intensity-modulated radiotherapy for recurrent and metastatic cervical cancer: the Shanghai Cancer Hospital experience.

    Directory of Open Access Journals (Sweden)

    Su-Ping Liu

    Full Text Available We evaluate the outcomes of irradiation by using three-dimensional radiation therapy (3D-RT or intensity-modulated radiotherapy (IMRT for recurrent and metastatic cervical cancer. Between 2007 and 2010, 50 patients with recurrent and metastatic cervical cancer were treated using 3D-RT or IMRT. The median time interval between the initial treatment and the start of irradiation was 12 (6-51 months. Salvage surgery was performed before irradiation in 5 patients, and 38 patients received concurrent chemotherapy. Sixteen patients underwent 3D-RT, and 34 patients received IMRT. Median follow-up for all the patients was 18.3 months. Three-year overall survival and locoregional control were 56.1% and 59.7%, respectively. Three-year progression-free survival and disease-free survival were 65.3% and 64.3%, respectively. Nine patients developed grade 3 leukopenia. Grade 5 acute toxicity was not observed in any of the patients; however, 2 patients developed Grade 3 late toxicity. 3D-RT or IMRT is effective for the treatment of recurrent and metastatic cervical cancer, with the 3-year overall survival of 56.1%, and its complications are acceptable. Long-term follow-up and further studies are needed to confirm the role of 3D-RT or IMRT in the multimodality management of the disease.

  16. Analysis of parotid gland and target volume variations during the head neck cancer intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Luo Jingwei; Fu Weihua; Xu Guozhen; Gao Li; Yan Di; Wu Qiuwen

    2006-01-01

    Objective: To study the changes in gross tumor volume (GTV) and parotid gland volume dur- ing intensity modulated radiation therapy (IMRT) for head and neck cancer. Methods: Five patients with head and neck squamous carcinoma were treated by IMRT. Cone beam CT was done every week during the whole course of radiotherapy. All images were fused with cone beam CT pictures and the initial CT pictures. The contouring was on normal parotid gland and gas cavity in each slide of cone beam CT. The changes of parotid gland and gas volume in GTV were calculated. Results: The parotid gland volume decreased, and gas volume in the GTV increased throughout the course of IMRT. At the end of radiotherapy, the parotid gland volume decreased to 90.1%- 52.3% compared with the volume before IMRT, gas cavity volume increased and took up to 3.7%-16.8% of GTV at the beginning of radiotherapy. Conclusion: Normal parotid gland volume and GTV is changed during IMRT in head and neck cancer. Cone beam CT can be used to find these changes which are helpful in carrying out the second IMRT plan. (authors)

  17. Correlation between patients' anatomical characteristics and interfractional internal prostate motion during intensity modulated radiation therapy for prostate cancer.

    Science.gov (United States)

    Maruoka, Shintaroh; Yoshioka, Yasuo; Isohashi, Fumiaki; Suzuki, Osamu; Seo, Yuji; Otani, Yuki; Akino, Yuichi; Takahashi, Yutaka; Sumida, Iori; Ogawa, Kazuhiko

    2015-01-01

    Intensity modulated radiation therapy (IMRT) is one of a standard treatment for localized prostate cancer. Although lower complication is expected for smaller target margin, determination of optimal margin is important. For bony-structure based registration, internal prostate motion is the main factor determining the margin from clinical target volume to planning target volume. The purpose of this study was to measure interfractional internal motion of the prostate and to identity the factors which enlarge or reduce the margin, with special focus on patients' anatomical characteristics. The 586 image sets of 16 patients acquired with megavoltage cone beam computed tomography were analyzed. For each patient, prostate shift in three directions was recorded for each fraction to calculate the required margin. Correlations between these values and patients' anatomical characteristics were evaluated. The posteriorly required margin correlated positively with rectal volume and rectal mean area (p = 0.015 and p = 0.008), while random error in lateral, craniocaudal and anteroposterior direction correlated negatively (p = 0.014, 0.04 and 0.0026, respectively) with body mass index (BMI). In addition to the previously identified factor of distended rectum, BMI was newly identified as another significant factor influencing interfractional internal prostate motion.

  18. A set cover approach to fast beam orientation optimization in intensity modulated radiation therapy for total marrow irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chieh-Hsiu Jason; Aleman, Dionne M [Department of Mechanical and Industrial Engineering, University of Toronto, 5 King' s College Road, Toronto, ON M5S 3G8 (Canada); Sharpe, Michael B, E-mail: chjlee@mie.utoronto.ca, E-mail: aleman@mie.utoronto.ca, E-mail: michael.sharpe@rmp.uhn.on.ca [Princess Margaret Hospital, Department of Radiation Oncology, University of Toronto, 610 University Avenue, Toronto, ON M5G 2M9 (Canada)

    2011-09-07

    The beam orientation optimization (BOO) problem in intensity modulated radiation therapy (IMRT) treatment planning is a nonlinear problem, and existing methods to obtain solutions to the BOO problem are time consuming due to the complex nature of the objective function and size of the solution space. These issues become even more difficult in total marrow irradiation (TMI), where many more beams must be used to cover a vastly larger treatment area than typical site-specific treatments (e.g., head-and-neck, prostate, etc). These complications result in excessively long computation times to develop IMRT treatment plans for TMI, so we attempt to develop methods that drastically reduce treatment planning time. We transform the BOO problem into the classical set cover problem (SCP) and use existing methods to solve SCP to obtain beam solutions. Although SCP is NP-Hard, our methods obtain beam solutions that result in quality treatments in minutes. We compare our approach to an integer programming solver for the SCP to illustrate the speed advantage of our approach.

  19. Objective assessment of trismus in oral and oropharyngeal cancer patients treated with intensity-modulated radiation therapy (IMRT).

    Science.gov (United States)

    Owosho, Adepitan A; Pedreira Ramalho, Luciana M; Rosenberg, Haley I; Yom, SaeHee K; Drill, Esther; Riedel, Elyn; Tsai, C Jillian; Lee, Nancy Y; Huryn, Joseph M; Estilo, Cherry L

    2016-09-01

    The aim of this study was to estimate the prevalence of trismus in oral and oropharyngeal cancer patients (OOPC) treated with intensity-modulated radiation therapy (IMRT) and to identify the role of risk factors in patients who developed trismus. A retrospective cohort study of OOPC treated with IMRT in our institution from 2009 to 2014 was performed. Patients eligible for this study had pre-RT and post-RT maximal inter-incisal opening (MIO) measurements at 6-48 months post-RT, treated with high-dose radiation (≥60 Gy) and pre-RT MIO ≥36 mm. A descriptive analysis to identify the incidence of trismus, with trismus stated as MIO ≤35 mm at or after 6 months post-RT measurement was performed. The role of risk factors such as age, gender, tumor site, tumor size (T), tumor stage, pre-RT MIO measurements and radiation dose to the tumor were assessed using Fisher exact test and the radiation doses to the ipsilateral muscles of mastication in patients who developed trismus were assessed by matching with control (non-trismus) patients using Wilcoxon Signed Rank test. The study consisted of 54 patients with a median age of 55 years and 81% were males. The median follow-up time was 10 months. The prevalence of trismus was 14.8%. Patients with pre-RT MIO measurements ≤40 mm were at risk of developing trismus (P trismus patients, the average mean radiation dose to the masseter and medial pterygoid muscles was numerically higher but not significantly different (P = 0.08; P = 0.22, respectively) to matched control patients. Age, gender, radiation dose to the tumor, tumor site, size (T) and stage were also found to be not significant. Pre-RT MIO measurement was a significant risk factor for the development of trismus. However, this is a non-modifiable factor. Limiting radiation dose to the muscles of mastication could prevent this complication. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Immobilization and positioning systems for treatment of patients with image-guided radiation therapy and intensity modulated radiation therapy)

    International Nuclear Information System (INIS)

    Hueso Bernad, M. Nuria; Suarez Dieguez, Raquel; Roures Ramos, M. Teresa; Broseta Tormos, M.Mercedes; Tirado Porcar, Miriam M; Del Castillo Arres, Jose; Franch Martinez, Silvia

    2009-01-01

    For adequate reproduction of daily patient positioning during treatment we use a 3-coordinate system alignment. The first set of axes would be the system of light (laser). - The second coordinate system is recognized by marks on the skin patient and / or immobilization systems. The third set of alignment refers to alignment of coordinates volume to try to locate the isocenter use Guided Radiotherapy Imaging when applied technologies with Intensity Modulated Radiotherapy treatment fields tend to be very small so it made individual protection and immobilization systems such as thermoplastic masks, vacuum sealed bags exterotaxicos conjugated systems and immobilization systems carbon fiber results by combining these immobilization and positioning systems can ensure effective treatment volume to be treated. There is no perfect immobilization system. However the choice of pool of qualified stun makes treatment more precise. (author)

  1. Impact of Multileaf Collimator Configuration Parameters on the Dosimetric Accuracy of 6-MV Intensity-Modulated Radiation Therapy Treatment Plans.

    Science.gov (United States)

    Petersen, Nick; Perrin, David; Newhauser, Wayne; Zhang, Rui

    2017-01-01

    The purpose of this study was to evaluate the impact of selected configuration parameters that govern multileaf collimator (MLC) transmission and rounded leaf offset in a commercial treatment planning system (TPS) (Pinnacle 3 , Philips Medical Systems, Andover, MA, USA) on the accuracy of intensity-modulated radiation therapy (IMRT) dose calculation. The MLC leaf transmission factor was modified based on measurements made with ionization chambers. The table of parameters containing rounded-leaf-end offset values was modified by measuring the radiation field edge as a function of leaf bank position with an ionization chamber in a scanning water-tank dosimetry system and comparing the locations to those predicted by the TPS. The modified parameter values were validated by performing IMRT quality assurance (QA) measurements on 19 gantry-static IMRT plans. Planar dose measurements were performed with radiographic film and a diode array (MapCHECK2) and compared to TPS calculated dose distributions using default and modified configuration parameters. Based on measurements, the leaf transmission factor was changed from a default value of 0.001 to 0.005. Surprisingly, this modification resulted in a small but statistically significant worsening of IMRT QA gamma-index passing rate, which revealed that the overall dosimetric accuracy of the TPS depends on multiple configuration parameters in a manner that is coupled and not intuitive because of the commissioning protocol used in our clinic. The rounded leaf offset table had little room for improvement, with the average difference between the default and modified offset values being -0.2 ± 0.7 mm. While our results depend on the current clinical protocols, treatment unit and TPS used, the methodology used in this study is generally applicable. Different clinics could potentially obtain different results and improve their dosimetric accuracy using our approach.

  2. Impact of multileaf collimator configuration parameters on the dosimetric accuracy of 6-MV Intensity-Modulated radiation therapy treatment plans

    Directory of Open Access Journals (Sweden)

    Nick Petersen

    2017-01-01

    Full Text Available The purpose of this study was to evaluate the impact of selected configuration parameters that govern multileaf collimator (MLC transmission and rounded leaf offset in a commercial treatment planning system (TPS (Pinnacle3, Philips Medical Systems, Andover, MA, USA on the accuracy of intensity-modulated radiation therapy (IMRT dose calculation. The MLC leaf transmission factor was modified based on measurements made with ionization chambers. The table of parameters containing rounded-leaf-end offset values was modified by measuring the radiation field edge as a function of leaf bank position with an ionization chamber in a scanning water-tank dosimetry system and comparing the locations to those predicted by the TPS. The modified parameter values were validated by performing IMRT quality assurance (QA measurements on 19 gantry-static IMRT plans. Planar dose measurements were performed with radiographic film and a diode array (MapCHECK2 and compared to TPS calculated dose distributions using default and modified configuration parameters. Based on measurements, the leaf transmission factor was changed from a default value of 0.001 to 0.005. Surprisingly, this modification resulted in a small but statistically significant worsening of IMRT QA gamma-index passing rate, which revealed that the overall dosimetric accuracy of the TPS depends on multiple configuration parameters in a manner that is coupled and not intuitive because of the commissioning protocol used in our clinic. The rounded leaf offset table had little room for improvement, with the average difference between the default and modified offset values being −0.2 ± 0.7 mm. While our results depend on the current clinical protocols, treatment unit and TPS used, the methodology used in this study is generally applicable. Different clinics could potentially obtain different results and improve their dosimetric accuracy using our approach.

  3. Influence of Parotid from Various Dose Rate in Intensity Modulated Radiation Therapy Planning for Head and Neck Cancer

    International Nuclear Information System (INIS)

    Hong, Joo Wan; Jeong, Yun Ju; Won, Hui Su; Chang, Nam Jun; Choi, Ji Hun; Seok, Jin Yong

    2010-01-01

    There are various beam parameter in intensity modulated radiation therapy (IMRT). The aim of this study is to investigate how various dose rate affect the parotid in treatment plan of IMRT. Materials and Methods: The study was performed on 10 nasopharyngeal carcinoma patients who have undergone IMRT. CT images were scanned 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). The parameters for planning used 6 MV energy and 8 beams under the same dose volume constraint. The variation of dose rates were used 300, 400, 500 MU/min. The mean dose of both parotid was accessed from the calculated planning among the 10 patients. The mean dose of parotid was verificated by 2D diode array (Mapcheck from Sun Nuclear Corporation, Melbourne, Florida). Also, Total monitor unit (MU) and beam-on time was analysed. Results: According to the dose rate, the mean dose of parotid was increased by 0.8%, 2.0% each, when dose rate was changed from 300 MU/min to 400, 500 MU/min, moreover Total MU was increased by 5.4% and 10.6% each. There was also a dose upward trend in the dose measurement of parotid by 2D diode array. However, beam - on time difference of 1-2 minutes was no significant in the dose rate increases. From this study, when the dose rates increase, there was a significant increase of Total MU and the parotid dose accordingly, however the shortened treatment time was not significant. Hence, it is considered that there is a significant decrease of late side effect in parotid radiation therapy, if the precise dose rate in IMRT is used.

  4. Cognitive Function Before and After Intensity-Modulated Radiation Therapy in Patients With Nasopharyngeal Carcinoma: A Prospective Study

    International Nuclear Information System (INIS)

    Hsiao, Kuan-Yin; Yeh, Shyh-An; Chang, Chiung-Chih

    2010-01-01

    Purpose: To evaluate the effects of radiation therapy (RT) on neurocognitive function in patients with nasopharyngeal carcinoma (NPC). Methods and Materials: Thirty patients with NPC treated with intensity-modulated RT were included. Dose-volume histograms of the temporal lobes were obtained in every patient. Neurocognitive tests were administered individually to each patient 1 day before initiation of RT and at least 12 months after completion of RT. Cognitive functioning status was evaluated as change in scores over time. Results: Among the total of 30 patients, 23 patients (76.7%) had significantly lower post-RT cognitive functioning scores compared with their pre-RT scores (p = 0.033). The cognitive functioning scores had significantly declined in the domains of short-term memory, language abilities, and list-generating fluency (p = 0.020, 0.023, and 0.001, respectively). Compared with patients with a mean dose to the temporal lobes of 36 Gy or less, patients with a mean dose of greater than 36 Gy had a significantly greater reduction in cognitive functioning scores (p = 0.017). Patients in whom V60 of the temporal lobes (i.e., the percentage of the temporal lobe volume that had received >60 Gy) was greater than 10% also had a greater reduction in cognitive functioning scores than those in whom V60 was 10% or less (p = 0.039). Conclusions: The results of our study indicated that RT could have deleterious effects on cognitive function in patients with NPC. Efforts should be made to reduce the radiation dose and irradiated volume of temporal lobes without compromising the coverage of target volume.

  5. XRCC3 polymorphisms are associated with the risk of developing radiation-induced late xerostomia in nasopharyngeal carcinoma patients treated with intensity modulation radiated therapy.

    Science.gov (United States)

    Zou, Yan; Song, Tao; Yu, Wei; Zhao, Ruping; Wang, Yong; Xie, Ruifei; Chen, Tian; Wu, Bo; Wu, Shixiu

    2014-03-01

    The incidence of radiation-induced late xerostomia varies greatly in nasopharyngeal carcinoma patients treated with radiotherapy. The single-nucleotide polymorphisms in genes involved in DNA repair and fibroblast proliferation may be correlated with such variability. The purpose of this paper was to evaluate the association between the risk of developing radiation-induced late xerostomia and four genetic polymorphisms: TGFβ1 C-509T, TGFβ1 T869C, XRCC3 722C>T and ATM 5557G>A in nasopharyngeal carcinoma patients treated with Intensity Modulation Radiated Therapy. The severity of late xerostomia was assessed using a patient self-reported validated xerostomia questionnaire. Polymerase chain reaction-ligation detection reaction methods were performed to determine individual genetic polymorphism. The development of radiation-induced xerostomia associated with genetic polymorphisms was modeled using Cox proportional hazards, accounting for equivalent uniform dose. A total of 43 (41.7%) patients experienced radiation-induced late xerostomia. Univariate Cox proportional hazard analyses showed a higher risk of late xerostomia for patients with XRCC3 722 TT/CT alleles. In multivariate analysis adjusted for clinical and dosimetric factors, XRCC3 722C>T polymorphisms remained a significant factor for higher risk of late xerostomia. To our knowledge, this is the first study that demonstrated an association between genetic polymorphisms and the risk of radiation-induced late xerostomia in nasopharyngeal carcinoma patients treated with Intensity Modulation Radiated Therapy. Our findings suggest that the polymorphisms in XRCC3 are significantly associated with the risk of developing radiation-induced late xerostomia.

  6. Intensity modulated radiation therapy for oropharyngeal cancer: the sensitivity of plan objectives and constraints to set-up uncertainty

    International Nuclear Information System (INIS)

    Ploquin, Nicolas; Song, William; Lau, Harold; Dunscombe, Peter

    2005-01-01

    The goal of this study was to assess the impact of set-up uncertainty on compliance with the objectives and constraints of an intensity modulated radiation therapy protocol for early stage cancer of the oropharynx. As the convolution approach to the quantitative study of set-up uncertainties cannot accommodate either surface contours or internal inhomogeneities, both of which are highly relevant to sites in the head and neck, we have employed the more resource intensive direct simulation method. The impact of both systematic (variable from 0 to 6 mm) and random (fixed at 2 mm) set-up uncertainties on compliance with the criteria of the RTOG H-0022 protocol has been examined for eight geometrically complex structures: CTV66 (gross tumour volume and palpable lymph nodes suspicious for metastases), CTV54 (lymph node groups or surgical neck levels at risk of subclinical metastases), glottic larynx, spinal cord, brainstem, mandible and left and right parotids. In a probability-based approach, both dose-volume histograms and equivalent uniform doses were used to describe the dose distributions achieved by plans for two patients, in the presence of set-up uncertainty. The equivalent uniform dose is defined to be that dose which, when delivered uniformly to the organ of interest, will lead to the same response as the non-uniform dose under consideration. For systematic set-up uncertainties greater than 2 mm and 5 mm respectively, coverage of the CTV66 and CTV54 could be significantly compromised. Directional sensitivity was observed in both cases. Most organs at risk (except the glottic larynx which did not comply under static conditions) continued to meet the dose constraints up to 4 mm systematic uncertainty for both plans. The exception was the contra lateral parotid gland, which this protocol is specifically designed to protect. Sensitivity to systematic set-up uncertainty of 2 mm was observed for this organ at risk in both clinical plans

  7. Limited Advantages of Intensity-Modulated Radiotherapy Over 3D Conformal Radiation Therapy in the Adjuvant Management of Gastric Cancer

    International Nuclear Information System (INIS)

    Alani, Shlomo; Soyfer, Viacheslav; Strauss, Natan; Schifter, Dan; Corn, Benjamin W.

    2009-01-01

    Purpose: Although chemoradiotherapy was considered the standard adjuvant treatment for gastric cancer, a recent Phase III trial (Medical Research Council Adjuvant Gastric Infusional Chemotherapy [MAGIC]) did not include radiotherapy in the randomization scheme because it was considered expendable. Given radiotherapy's potential, efforts needed to be made to optimize its use for treating gastric cancer. We assessed whether intensity-modulated radiotherapy (IMRT) could improve upon our published results in patients treated with three-dimensional (3D) conformal therapy. Methods and Materials: Fourteen patients with adenocarcinoma of the stomach were treated with adjuvant chemoradiotherapy using a noncoplanar four-field arrangement. Subsequently, a nine-field IMRT plan was designed using a CMS Xio IMRT version 4.3.3 module. Two IMRT beam arrangements were evaluated: beam arrangement 1 consisted of gantry angles of 0 deg., 53 deg., 107 deg., 158 deg., 204 deg., 255 deg., and 306 deg.. Beam arrangement 2 consisted of gantry angles of 30 deg., 90 deg., 315 deg., and 345 deg.; a gantry angle of 320 deg./couch, 30 deg.; and a gantry angle of 35 o /couch, 312 o . Both the target volume coverage and the dose deposition in adjacent critical organs were assessed in the plans. Dose-volume histograms were generated for the clinical target volume, kidneys, spine, and liver. Results: Comparison of the clinical target volumes revealed satisfactory coverage by the 95% isodose envelope using either IMRT or 3D conformal therapy. However, IMRT was only marginally better than 3D conformal therapy at protecting the spine and kidneys from radiation. Conclusions: IMRT confers only a marginal benefit in the adjuvant treatment of gastric cancer and should be used only in the small subset of patients with risk factors for kidney disease or those with a preexisting nephropathy.

  8. Limited advantages of intensity-modulated radiotherapy over 3D conformal radiation therapy in the adjuvant management of gastric cancer.

    Science.gov (United States)

    Alani, Shlomo; Soyfer, Viacheslav; Strauss, Natan; Schifter, Dan; Corn, Benjamin W

    2009-06-01

    Although chemoradiotherapy was considered the standard adjuvant treatment for gastric cancer, a recent Phase III trial (Medical Research Council Adjuvant Gastric Infusional Chemotherapy [MAGIC]) did not include radiotherapy in the randomization scheme because it was considered expendable. Given radiotherapy's potential, efforts needed to be made to optimize its use for treating gastric cancer. We assessed whether intensity-modulated radiotherapy (IMRT) could improve upon our published results in patients treated with three-dimensional (3D) conformal therapy. Fourteen patients with adenocarcinoma of the stomach were treated with adjuvant chemoradiotherapy using a noncoplanar four-field arrangement. Subsequently, a nine-field IMRT plan was designed using a CMS Xio IMRT version 4.3.3 module. Two IMRT beam arrangements were evaluated: beam arrangement 1 consisted of gantry angles of 0 degrees , 53 degrees , 107 degrees , 158 degrees , 204 degrees , 255 degrees , and 306 degrees . Beam arrangement 2 consisted of gantry angles of 30 degrees , 90 degrees , 315 degrees , and 345 degrees ; a gantry angle of 320 degrees /couch, 30 degrees ; and a gantry angle of 35 degrees /couch, 312 degrees . Both the target volume coverage and the dose deposition in adjacent critical organs were assessed in the plans. Dose-volume histograms were generated for the clinical target volume, kidneys, spine, and liver. Comparison of the clinical target volumes revealed satisfactory coverage by the 95% isodose envelope using either IMRT or 3D conformal therapy. However, IMRT was only marginally better than 3D conformal therapy at protecting the spine and kidneys from radiation. IMRT confers only a marginal benefit in the adjuvant treatment of gastric cancer and should be used only in the small subset of patients with risk factors for kidney disease or those with a preexisting nephropathy.

  9. Intensity modulated radiation therapy for oropharyngeal cancer: the sensitivity of plan objectives and constraints to set-up uncertainty

    Science.gov (United States)

    Ploquin, Nicolas; Song, William; Lau, Harold; Dunscombe, Peter

    2005-08-01

    The goal of this study was to assess the impact of set-up uncertainty on compliance with the objectives and constraints of an intensity modulated radiation therapy protocol for early stage cancer of the oropharynx. As the convolution approach to the quantitative study of set-up uncertainties cannot accommodate either surface contours or internal inhomogeneities, both of which are highly relevant to sites in the head and neck, we have employed the more resource intensive direct simulation method. The impact of both systematic (variable from 0 to 6 mm) and random (fixed at 2 mm) set-up uncertainties on compliance with the criteria of the RTOG H-0022 protocol has been examined for eight geometrically complex structures: CTV66 (gross tumour volume and palpable lymph nodes suspicious for metastases), CTV54 (lymph node groups or surgical neck levels at risk of subclinical metastases), glottic larynx, spinal cord, brainstem, mandible and left and right parotids. In a probability-based approach, both dose-volume histograms and equivalent uniform doses were used to describe the dose distributions achieved by plans for two patients, in the presence of set-up uncertainty. The equivalent uniform dose is defined to be that dose which, when delivered uniformly to the organ of interest, will lead to the same response as the non-uniform dose under consideration. For systematic set-up uncertainties greater than 2 mm and 5 mm respectively, coverage of the CTV66 and CTV54 could be significantly compromised. Directional sensitivity was observed in both cases. Most organs at risk (except the glottic larynx which did not comply under static conditions) continued to meet the dose constraints up to 4 mm systematic uncertainty for both plans. The exception was the contra lateral parotid gland, which this protocol is specifically designed to protect. Sensitivity to systematic set-up uncertainty of 2 mm was observed for this organ at risk in both clinical plans.

  10. Hypofractionated Intensity Modulated Radiation Therapy in Combined Modality Treatment for Bladder Preservation in Elderly Patients With Invasive Bladder Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Turgeon, Guy-Anne [Department of Oncology, Division of Radiation Oncology, McGill University Health Centre, Montreal, Quebec (Canada); Souhami, Luis, E-mail: luis.souhami@muhc.mcgill.ca [Department of Oncology, Division of Radiation Oncology, McGill University Health Centre, Montreal, Quebec (Canada); Cury, Fabio L.; Faria, Sergio L.; Duclos, Marie [Department of Oncology, Division of Radiation Oncology, McGill University Health Centre, Montreal, Quebec (Canada); Sturgeon, Jeremy [Department of Medical Oncology, McGill University Health Centre, Montreal, Quebec (Canada); Kassouf, Wassim [Department of Urology, McGill University Health Centre, Montreal, Quebec (Canada)

    2014-02-01

    Purpose/Objective(s): To review our experience with bladder-preserving trimodality treatment (TMT) using hypofractionated intensity modulated radiation therapy (IMRT) for the treatment of elderly patients with muscle-invasive bladder cancer. Methods and Materials: Retrospective study of elderly patients treated with TMT using hypofractionated IMRT (50 Gy in 20 fractions) with concomitant weekly radiosensitizing chemotherapy. Eligibility criteria were as follows: age ≥70 years, a proven diagnosis of muscle-invasive transitional cell bladder carcinoma, stage T2-T3N0M0 disease, and receipt of TMT with curative intent. Response rate was assessed by cystoscopic evaluation and bladder biopsy. Results: 24 patients with a median age of 79 years were eligible. A complete response was confirmed in 83% of the patients. Of the remaining patients, 1 of them underwent salvage cystectomy, and no disease was found in the bladder on histopathologic assessment. After a median follow-up time of 28 months, of the patients with a complete response, 2 patients had muscle-invasive recurrence, 1 experienced locoregional failure, and 3 experienced distant metastasis. The overall and cancer-specific survival rates at 3 years were 61% and 71%, respectively. Of the surviving patients, 75% have a disease-free and functioning bladder. All patients completed hypofractionated IMRT, and 19 patients tolerated all 4 cycles of chemotherapy. Acute grade 3 gastrointestinal or genitourinary toxicities occurred in only 4% of the patients, and acute grade 3 or 4 hematologic toxicities, liver toxicities, or both were experienced by 17% of the cohort. No patient experienced grade 4 gastrointestinal or genitourinary toxicity. Conclusions: Hypofractionated IMRT with concurrent radiosensitizing chemotherapy appears to be an effective and well-tolerated curative treatment strategy in the elderly population and should be considered for patients who are not candidates for cystectomy or who wish to avoid

  11. Dose–volume-related dysphagia after constrictor muscles definition in head and neck cancer intensity-modulated radiation treatment

    Science.gov (United States)

    Mazzola, R; Ricchetti, F; Fiorentino, A; Fersino, S; Giaj Levra, N; Naccarato, S; Sicignano, G; Albanese, S; Di Paola, G; Alterio, D; Ruggieri, R

    2014-01-01

    Objective: Dysphagia remains a side effect influencing the quality of life of patients with head and neck cancer (HNC) after radiotherapy. We evaluated the relationship between planned dose involvement and acute and late dysphagia in patients with HNC treated with intensity-modulated radiation therapy (IMRT), after a recontouring of constrictor muscles (PCs) and the cricopharyngeal muscle (CM). Methods: Between December 2011 and December 2013, 56 patients with histologically proven HNC were treated with IMRT or volumetric-modulated arc therapy. The PCs and CM were recontoured. Correlations between acute and late toxicity and dosimetric parameters were evaluated. End points were analysed using univariate logistic regression. Results: An increasing risk to develop acute dysphagia was observed when constraints to the middle PCs were not respected [mean dose (Dmean) ≥50 Gy, maximum dose (Dmax) >60 Gy, V50 >70% with a p = 0.05]. The superior PC was not correlated with acute toxicity but only with late dysphagia. The inferior PC was not correlated with dysphagia; for the CM only, Dmax >60 Gy was correlated with acute dysphagia ≥ grade 2. Conclusion: According to our analysis, the superior PC has a major role, being correlated with dysphagia at 3 and 6 months after treatments; the middle PC maintains this correlation only at 3 months from the beginning of radiotherapy, but it does not have influence on late dysphagia. The inferior PC and CM have a minimum impact on swallowing symptoms. Advances in knowledge: We used recent guidelines to define dose constraints of the PCs and CM. Two results emerge in the present analysis: the superior PC influences late dysphagia, while the middle PC influences acute dysphagia. PMID:25348370

  12. Dose-volume-related dysphagia after constrictor muscles definition in head and neck cancer intensity-modulated radiation treatment.

    Science.gov (United States)

    Mazzola, R; Ricchetti, F; Fiorentino, A; Fersino, S; Giaj Levra, N; Naccarato, S; Sicignano, G; Albanese, S; Di Paola, G; Alterio, D; Ruggieri, R; Alongi, F

    2014-12-01

    Dysphagia remains a side effect influencing the quality of life of patients with head and neck cancer (HNC) after radiotherapy. We evaluated the relationship between planned dose involvement and acute and late dysphagia in patients with HNC treated with intensity-modulated radiation therapy (IMRT), after a recontouring of constrictor muscles (PCs) and the cricopharyngeal muscle (CM). Between December 2011 and December 2013, 56 patients with histologically proven HNC were treated with IMRT or volumetric-modulated arc therapy. The PCs and CM were recontoured. Correlations between acute and late toxicity and dosimetric parameters were evaluated. End points were analysed using univariate logistic regression. An increasing risk to develop acute dysphagia was observed when constraints to the middle PCs were not respected [mean dose (Dmean) ≥50 Gy, maximum dose (Dmax) >60 Gy, V50 >70% with a p = 0.05]. The superior PC was not correlated with acute toxicity but only with late dysphagia. The inferior PC was not correlated with dysphagia; for the CM only, Dmax >60 Gy was correlated with acute dysphagia ≥ grade 2. According to our analysis, the superior PC has a major role, being correlated with dysphagia at 3 and 6 months after treatments; the middle PC maintains this correlation only at 3 months from the beginning of radiotherapy, but it does not have influence on late dysphagia. The inferior PC and CM have a minimum impact on swallowing symptoms. We used recent guidelines to define dose constraints of the PCs and CM. Two results emerge in the present analysis: the superior PC influences late dysphagia, while the middle PC influences acute dysphagia.

  13. Using total-variation regularization for intensity modulated radiation therapy inverse planning with field-specific numbers of segments

    International Nuclear Information System (INIS)

    Zhu Lei; Lee, Louis; Ma Yunzhi; Xing Lei; Ye Yinyu; Mazzeo, Rafe

    2008-01-01

    Currently, there are two types of treatment planning algorithms for intensity modulated radiation therapy (IMRT). The beamlet-based algorithm generates beamlet intensity maps with high complexity, resulting in large numbers of segments in the delivery after a leaf-sequencing algorithm is applied. The segment-based direct aperture optimization (DAO) algorithm includes the physical constraints of the deliverable apertures in the calculation, and achieves a conformal dose distribution using a small number of segments. However, the number of segments is pre-fixed in most of the DAO approaches, and the typical random search scheme in the optimization is computationally intensive. A regularization-based algorithm is proposed to overcome the drawbacks of the DAO method. Instead of smoothing the beamlet intensity maps as in many existing methods, we include a total-variation term in the optimization objective function to reduce the number of signal levels of the beam intensity maps. An aperture rectification algorithm is then applied to generate a significantly reduced number of deliverable apertures. As compared to the DAO algorithm, our method has an efficient form of quadratic optimization, with an additional advantage of optimizing field-specific numbers of segments based on the modulation complexity. The proposed approach is evaluated using two clinical cases. Under the condition that the clinical acceptance criteria of the treatment plan are satisfied, for the prostate patient, the total number of segments for five fields is reduced from 61 using the Eclipse planning system to 35 using the proposed algorithm; for the head and neck patient, the total number of segments for seven fields is reduced from 107 to 28. The head and neck result is also compared to that using an equal number of four segments for each field. The comparison shows that using field-specific numbers of segments achieves a much improved dose distribution.

  14. A Treatment Planning Analysis of Inverse-Planned and Forward-Planned Intensity-Modulated Radiation Therapy in Nasopharyngeal Carcinoma

    International Nuclear Information System (INIS)

    Poon, Ian M; Xia Ping; Weinberg, Vivien; Sultanem, Khalil; Akazawa, Clayton C.; Akazawa, Pamela C.; Verhey, Lynn; Quivey, Jeanne Marie; Lee, Nancy

    2007-01-01

    Purpose: To compare dose-volume histograms of target volumes and organs at risk in 57 patients with nasopharyngeal carcinoma (NPC) with inverse- (IP) or forward-planned (FP) intensity-modulated radiation treatment (IMRT). Methods and Materials: The DVHs of 57 patients with NPC with IMRT with or without chemotherapy were reviewed. Thirty-one patients underwent IP IMRT, and 26 patients underwent FP IMRT. Treatment goals were to prescribe a minimum dose of 66-70 Gy for gross tumor volume and 59.4 Gy for planning target volume to greater than 95% of the volume. Multiple selected end points were used to compare dose-volume histograms of the targets, including minimum, mean, and maximum doses; percentage of target volume receiving less than 90% (1-V90%), less than 95% (1-V95%), and greater than 105% (1-V105%). Dose-volume histograms of organs at risk were evaluated with characteristic end points. Results: Both planning methods provided excellent target coverage with no statistically significant differences found, although a trend was suggested in favor of improved target coverage with IP IMRT in patients with T3/T4 NPC (p = 0.10). Overall, IP IMRT statistically decreased the dose to the parotid gland, temporomandibular joint, brain stem, and spinal cord overall, whereas IP led to a dose decrease to the middle/inner ear in only the T1/T2 subgroup. Conclusions: Use of IP and FP IMRT can lead to good target coverage while maintaining critical structures within tolerance. The IP IMRT selectively spared these critical organs to a greater degree and should be considered the standard of treatment in patients with NPC, particularly those with T3/T4. The FP IMRT is an effective second option in centers with limited IP IMRT capacity. As a modification of conformal techniques, the human/departmental resources to incorporate FP-IMRT should be nominal

  15. Acute toxicity profile of craniospinal irradiation with intensity-modulated radiation therapy in children with medulloblastoma: A prospective analysis

    International Nuclear Information System (INIS)

    Cox, Maurice C.; Kusters, Johannes M.; Gidding, Corrie E.; Schieving, Jolanda H.; Lindert, Erik J. van; Kaanders, Johannes H.; Janssens, Geert O.

    2015-01-01

    To report on the acute toxicity in children with medulloblastoma undergoing intensity-modulated radiation therapy (IMRT) with daily intrafractionally modulated junctions. Newly diagnosed patients, aged 3–21, with standard-risk (SR) or high-risk (HR) medulloblastoma were eligible. A dose of 23.4 or 36.0Gy in daily fractions of 1.8Gy was prescribed to the craniospinal axis, followed by a boost to the primary tumor bed (54 or 55.8Gy) and metastases (39.6–55.8Gy), when indicated. Weekly, an intravenous bolus of vincristine was combined for patients with SR medulloblastoma and patients participating in the COG-ACNS-0332 study. Common toxicity criteria (CTC, version 2.0) focusing on skin, alopecia, voice changes, conjunctivitis, anorexia, dysphagia, gastro-intestinal symptoms, headache, fatigue and hematological changes were scored weekly during radiotherapy. From 2010 to 2014, data from 15 consecutive patients (SR, n = 7; HR, n = 8) were collected. Within 72 h from onset of treatment, vomiting (66 %) and headache (46 %) occurred. During week 3 of treatment, a peak incidence in constipation (33 %) and abdominal pain/cramping (40 %) was observed, but only in the subgroup of patients (n = 9) receiving vincristine (constipation: 56 vs 0 %, P = .04; pain/cramping: 67 vs 0 %, P = .03). At week 6, 73 % of the patients developed faint erythema of the cranial skin with dry desquamation (40 %) or moist desquamation confined to the skin folds of the auricle (33 %). No reaction of the skin overlying the spinal target volume was observed. Headache at onset and gastro-intestinal toxicity, especially in patients receiving weekly vincristine, were the major complaints of patients with medulloblastoma undergoing craniospinal irradiation with IMRT

  16. Hypofractionated intensity modulated radiation therapy in combined modality treatment for bladder preservation in elderly patients with invasive bladder cancer.

    Science.gov (United States)

    Turgeon, Guy-Anne; Souhami, Luis; Cury, Fabio L; Faria, Sergio L; Duclos, Marie; Sturgeon, Jeremy; Kassouf, Wassim

    2014-02-01

    To review our experience with bladder-preserving trimodality treatment (TMT) using hypofractionated intensity modulated radiation therapy (IMRT) for the treatment of elderly patients with muscle-invasive bladder cancer. Retrospective study of elderly patients treated with TMT using hypofractionated IMRT (50 Gy in 20 fractions) with concomitant weekly radiosensitizing chemotherapy. Eligibility criteria were as follows: age ≥70 years, a proven diagnosis of muscle-invasive transitional cell bladder carcinoma, stage T2-T3N0M0 disease, and receipt of TMT with curative intent. Response rate was assessed by cystoscopic evaluation and bladder biopsy. 24 patients with a median age of 79 years were eligible. A complete response was confirmed in 83% of the patients. Of the remaining patients, 1 of them underwent salvage cystectomy, and no disease was found in the bladder on histopathologic assessment. After a median follow-up time of 28 months, of the patients with a complete response, 2 patients had muscle-invasive recurrence, 1 experienced locoregional failure, and 3 experienced distant metastasis. The overall and cancer-specific survival rates at 3 years were 61% and 71%, respectively. Of the surviving patients, 75% have a disease-free and functioning bladder. All patients completed hypofractionated IMRT, and 19 patients tolerated all 4 cycles of chemotherapy. Acute grade 3 gastrointestinal or genitourinary toxicities occurred in only 4% of the patients, and acute grade 3 or 4 hematologic toxicities, liver toxicities, or both were experienced by 17% of the cohort. No patient experienced grade 4 gastrointestinal or genitourinary toxicity. Hypofractionated IMRT with concurrent radiosensitizing chemotherapy appears to be an effective and well-tolerated curative treatment strategy in the elderly population and should be considered for patients who are not candidates for cystectomy or who wish to avoid cystectomy. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Stereotactic intensity-modulated radiation therapy (IMRT) and inverse treatment planning for advanced pleural mesothelioma. Feasibility and initial results

    Energy Technology Data Exchange (ETDEWEB)

    Muenter, M.W.; Thilmann, C.; Hof, H.; Debus, J. [Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (dkfz), Heidelberg (Germany); Nill, S.; Hoess, A.; Partridge, M. [Dept. of Medical Physics, German Cancer Research Center (dkfz), Heidelberg (Germany); Haering, P. [Dept. of Central Dosimetry, German Cancer Research Center (dkfz), Heidelberg (Germany); Manegold, C. [Dept. of Medical Oncology/Internal Medicine, Thoraxklinik Heidelberg gGmbH, Heidelberg (Germany); Wannenmacher, M. [Dept. of Clinical Radiology, Univ. of Heidelberg, Heidelberg (Germany)

    2003-08-01

    Background and Purpose: Complex-shaped malignant pleural mesotheliomas (MPMs) with challenging volumes are extremely difficult to treat by conventional radiotherapy due to tolerance doses of the surrounding normal tissue. In a feasibility study, we evaluated if inversely planned stereotactic intensity-modulated radiation therapy (IMRT) could be applied in the treatment of MPM. Patients and Methods: Eight patients with unresectable lesions were treated after failure of chemotherapy. All patients were positioned using noninvasive patient fixation techniques which can be attached to the applied extracranial stereotactic system. Due to craniocaudal extension of the tumor, it was necessary to develop a special software attached to the inverse planning program KonRad, which can connect two inverse treatment plans and consider the applied dose of the first treatment plan in the area of the matchline of the second treatment plan. Results: Except for one patient, in whom radiotherapy was canceled due to abdominal metastasis, treatment could be completed in all patients and was well tolerated. Median survival after diagnosis was 20 months and after IMRT 6.5 months. Therefore, both the 1-year actuarial overall survival from the start of radiotherapy and the 2-year actuarial overall survival since diagnosis were 28%. IMRT did not result in clinically significant acute side effects. By using the described inverse planning software, over- or underdosage in the region of the field matchline could be prevented. Pure treatment time ranged between 10 and 21 min. Conclusion: This study showed that IMRT is feasible in advanced unresectable MPM. The presented possibilities of stereotactic IMRT in the treatment of MPM will justify the evaluation of IMRT in early-stage pleural mesothelioma combined with chemotherapy in a study protocol, in order to improve the outcome of these patients. Furthermore, dose escalation should be possible by using IMRT. (orig.)

  18. A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer

    Directory of Open Access Journals (Sweden)

    Foroudi Farshad

    2012-07-01

    Full Text Available Abstract Background To compare 3 Dimensional Conformal radiotherapy (3D-CRT with Intensity Modulated Radiotherapy (IMRT with Volumetric-Modulated Arc Therapy (VMAT for bladder cancer. Methods Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planning and the same clinical dosimetric constraints were used. 10 of the patients with well localised tumours had a simultaneous infield boost (SIB of the primary tumour planned for both IMRT and VMAT. Tumour control probabilities and normal tissue complication probabilities were calculated. Results Mean planning time for 3D-CRT, IMRT and VMAT was 30.0, 49.3, and 141.0 minutes respectively. The mean PTV conformity (CI index for 3D-CRT was 1.32, for IMRT 1.05, and for VMAT 1.05. The PTV Homogeneity (HI index was 0.080 for 3D-CRT, 0.073 for IMRT and 0.086 for VMAT. Tumour control and normal tissue complication probabilities were similar for 3D-CRT, IMRT and VMAT. The mean monitor units were 267 (range 250–293 for 3D-CRT; 824 (range 641–1083 for IMRT; and 403 (range 333–489 for VMAT (P  Conclusions VMAT is associated with similar dosimetric advantages as IMRT over 3D-CRT for muscle invasive bladder cancer. VMAT is associated with faster delivery times and less number of mean monitor units than IMRT. SIB is feasible in selected patients with localized tumours.

  19. Dosimetric evaluation of a moving tumor target in intensity-modulated radiation therapy (IMRT) for lung cancer patients

    Science.gov (United States)

    Kim, Sung Kyu; Kang, Min Kyu; Yea, Ji Woon; Oh, Se An

    2013-07-01

    Immobilization plays an important role in intensity-modulated radiation therapy (IMRT). The application of IMRT in lung cancer patients is very difficult due to the movement of the tumor target. Patient setup in radiation treatment demands high accuracy because IMRT employs a treatment size of a 1mm pixel unit. Hence, quality assurance of the dose delivered to patients must be at its highest. The radiation dose was evaluated for breathing rates of 9, 14, and 18 breaths per minute (bpm) for tumor targets moving up and down by 1.0 cm and 1.5 cm. The dose of the moving planned target volume (PTV) was measured by using a thermo-luminescent dosimeter (TLD) and Gafchromic™ EBT film. The measurement points were 1.0 cm away from the top, the bottom and the left and the right sides of the PTV center. The evaluated dose differences ranged from 94.2 to 103.8%, from 94.4 to 105.4%, and from 90.7 to 108.5% for 9, 14 and 18 bpm, respectively, for a tumor movement of 1.0 cm. The mean values of the doses were 101.4, 99.9, and 99.5% for 9, 14 and 18 bpm, respectively, for a tumor movement of 1.0 cm. Meanwhile, the evaluated dose differences ranged from 93.6 to 105.8%, from 95.9 to 111.5%, and from 96.2 to 111.7% for 9, 14 and 18 bpm, respectively, for a tumor movement of 1.5 cm. The mean values of the doses were 102.3, 103.4, and 103.1% for 9, 14 and 18 bpm, respectively, for a tumor movement of 1.5 cm. Therefore, we suggest that IMRT can be used in the treatment of lung cancer patients with vertical target movements within the range of 1.0 to 1.5 cm.

  20. Involved-Site Image-Guided Intensity Modulated Versus 3D Conformal Radiation Therapy in Early Stage Supradiaphragmatic Hodgkin Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Filippi, Andrea Riccardo, E-mail: andreariccardo.filippi@unito.it [Department of Oncology, University of Torino, Torino (Italy); Ciammella, Patrizia [Radiation Therapy Unit, Department of Oncology and Advanced Technology, ASMN Hospital IRCCS, Reggio Emilia (Italy); Piva, Cristina; Ragona, Riccardo [Department of Oncology, University of Torino, Torino (Italy); Botto, Barbara [Hematology, Città della Salute e della Scienza, Torino (Italy); Gavarotti, Paolo [Hematology, University of Torino and Città della Salute e della Scienza, Torino (Italy); Merli, Francesco [Hematology Unit, ASMN Hospital IRCCS, Reggio Emilia (Italy); Vitolo, Umberto [Hematology, Città della Salute e della Scienza, Torino (Italy); Iotti, Cinzia [Radiation Therapy Unit, Department of Oncology and Advanced Technology, ASMN Hospital IRCCS, Reggio Emilia (Italy); Ricardi, Umberto [Department of Oncology, University of Torino, Torino (Italy)

    2014-06-01

    Purpose: Image-guided intensity modulated radiation therapy (IG-IMRT) allows for margin reduction and highly conformal dose distribution, with consistent advantages in sparing of normal tissues. The purpose of this retrospective study was to compare involved-site IG-IMRT with involved-site 3D conformal RT (3D-CRT) in the treatment of early stage Hodgkin lymphoma (HL) involving the mediastinum, with efficacy and toxicity as primary clinical endpoints. Methods and Materials: We analyzed 90 stage IIA HL patients treated with either involved-site 3D-CRT or IG-IMRT between 2005 and 2012 in 2 different institutions. Inclusion criteria were favorable or unfavorable disease (according to European Organization for Research and Treatment of Cancer criteria), complete response after 3 to 4 cycles of an adriamycin- bleomycin-vinblastine-dacarbazine (ABVD) regimen plus 30 Gy as total radiation dose. Exclusion criteria were chemotherapy other than ABVD, partial response after ABVD, total radiation dose other than 30 Gy. Clinical endpoints were relapse-free survival (RFS) and acute toxicity. Results: Forty-nine patients were treated with 3D-CRT (54.4%) and 41 with IG-IMRT (45.6%). Median follow-up time was 54.2 months for 3D-CRT and 24.1 months for IG-IMRT. No differences in RFS were observed between the 2 groups, with 1 relapse each. Three-year RFS was 98.7% for 3D-CRT and 100% for IG-IMRT. Grade 2 toxicity events, mainly mucositis, were recorded in 32.7% of 3D-CRT patients (16 of 49) and in 9.8% of IG-IMRT patients (4 of 41). IG-IMRT was significantly associated with a lower incidence of grade 2 acute toxicity (P=.043). Conclusions: RFS rates at 3 years were extremely high in both groups, albeit the median follow-up time is different. Acute tolerance profiles were better for IG-IMRT than for 3D-CRT. Our preliminary results support the clinical safety and efficacy of advanced RT planning and delivery techniques in patients affected with early stage HL, achieving complete

  1. On the use of computed radiography plates for quality assurance of intensity modulated radiation therapy dose distributions.

    Science.gov (United States)

    Day, R A; Sankar, A P; Nailon, W H; MacLeod, A S

    2011-02-01

    As traditional film is phased out in most radiotherapy centers, computed radiography (CR) systems are increasingly being purchased as a replacement. CR plates can be used for patient imaging, but may also be used for a variety of quality assurance (QA) purposes and can be calibrated in terms of dose. This study looks at their suitability for verification of intensity modulated radiation therapy (IMRT) dose distributions. A CR plate was calibrated in terms of the relative dose and the stability of response over 1 year was studied. The effect of exposing the CR plate to ambient light and of using different time delays before scanning was quantified. The CR plate was used to verify the relative dose distributions for ten IMRT patients and the results were compared to those obtained using a two dimensional (2D) diode array. Exposing the CR plate to 10 s of ambient light between irradiation (174 cGy) and scanning erased approximately 80% of the signal. Changes in delay time between irradiation and scanning also affected the measurement results. The signal on the plate was found to decay at a rate of approximately 3.6 cGy/min in the first 10 min after irradiation. The use of a CR plate for IMRT patient-specific QA resulted in a significantly lower distance to agreement (DTA) and gamma pass rate than when using a 2D diode array for the measurement. This was primarily due to the over-response of the CR phosphor to low energy scattered radiation. For the IMRT QA using the CR plate, the average gamma pass rate was 97.3%. For the same IMRT QA using a diode array, the average gamma pass rate was 99.7%. The gamma criteria used were 4% dose difference and 4 mm DTA for head and neck treatments and 3% dose difference and 3 mm DTA for prostate treatments. The gamma index tolerance was 1. The lowest 10% of the dose distribution was excluded from all gamma and DTA analyses. Although the authors showed that CR plates can be used for patient specific IMRT QA, the practical problems

  2. On the use of computed radiography plates for quality assurance of intensity modulated radiation therapy dose distributions

    Energy Technology Data Exchange (ETDEWEB)

    Day, R. A.; Sankar, A. P.; Nailon, W. H.; MacLeod, A. S. [Department of Oncology Physics, Edinburgh Cancer Centre, Western General Hospital, Crewe Road South, Edinburgh EH4 2XU (United Kingdom)

    2011-02-15

    Purpose: As traditional film is phased out in most radiotherapy centers, computed radiography (CR) systems are increasingly being purchased as a replacement. CR plates can be used for patient imaging, but may also be used for a variety of quality assurance (QA) purposes and can be calibrated in terms of dose. This study looks at their suitability for verification of intensity modulated radiation therapy (IMRT) dose distributions. Methods: A CR plate was calibrated in terms of the relative dose and the stability of response over 1 year was studied. The effect of exposing the CR plate to ambient light and of using different time delays before scanning was quantified. The CR plate was used to verify the relative dose distributions for ten IMRT patients and the results were compared to those obtained using a two dimensional (2D) diode array. Results: Exposing the CR plate to 10 s of ambient light between irradiation (174 cGy) and scanning erased approximately 80% of the signal. Changes in delay time between irradiation and scanning also affected the measurement results. The signal on the plate was found to decay at a rate of approximately 3.6 cGy/min in the first 10 min after irradiation. The use of a CR plate for IMRT patient-specific QA resulted in a significantly lower distance to agreement (DTA) and gamma pass rate than when using a 2D diode array for the measurement. This was primarily due to the over-response of the CR phosphor to low energy scattered radiation. For the IMRT QA using the CR plate, the average gamma pass rate was 97.3%. For the same IMRT QA using a diode array, the average gamma pass rate was 99.7%. The gamma criteria used were 4% dose difference and 4 mm DTA for head and neck treatments and 3% dose difference and 3 mm DTA for prostate treatments. The gamma index tolerance was 1. The lowest 10% of the dose distribution was excluded from all gamma and DTA analyses. Conclusions: Although the authors showed that CR plates can be used for patient

  3. Intensity-modulated radiation therapy (IMRT) for nasopharynx cancer: Update of the Memorial Sloan-Kettering experience

    International Nuclear Information System (INIS)

    Wolden, Suzanne L.; Chen, William C.; Pfister, David G.; Kraus, Dennis H.; Berry, Sean L.; Zelefsky, Michael J.

    2006-01-01

    Purpose: We previously demonstrated that intensity-modulated radiation therapy (IMRT) significantly improves radiation dose distribution over three-dimensional planning for nasopharynx cancer and reported positive early clinical results. We now evaluate whether IMRT has resulted in improved outcomes for a larger cohort of patients with longer follow-up. Methods and Materials: Since 1998, all 74 patients with newly diagnosed, nonmetastatic nasopharynx cancer were treated with IMRT using accelerated fractionation to 70 Gy; 59 received a hyperfractionated concomitant boost, and more recently 15 received once-daily treatment with dose painting. With the exception of Stage I disease (n = 5) and patient preference (n = 1), 69 patients received concurrent and adjuvant platinum-based chemotherapy similar to that in the Intergroup 0099 trial. Results: Patient characteristics: median age 45; 32% Asian; 72% male; 65% World Health Organization III; 6% Stage I, 16% Stage II, 30% Stage III, 47% Stage IV. Median follow-up is 35 months. The 3-year actuarial rate of local control is 91%, and regional control is 93%; freedom from distant metastases, progression-free survival, and overall survival at 3 years are 78%, 67%, and 83%, respectively. There was 100% local control for Stage T1/T2 disease, compared to 83% for T3/T4 disease (p = 0.01). Six patients failed at the primary site, with median time to local tumor progression 16 months; 5 were exclusively within the 70 Gy volume, and 1 was both within and outside the target volume. There is a trend for improved local control with IMRT when compared to local control of 79% for 35 patients treated before 1998 with three-dimensional planning and chemotherapy (p 0.11). Six months posttherapy, 21%, 13%, 15%, and 0% of patients with follow-up audiograms (n = 24 patients) had Grade 1, 2, 3, and 4 sensorineural hearing loss, respectively. For patients with >1 year follow-up (n = 59), rates of long-term xerostomia were as follows: 26% none

  4. Dose non-linearity of the dosimetry system and possible monitor unit errors on medical linear accelerators used in conventional and intensity-modulated radiation therapy

    OpenAIRE

    Muhammad Wazir; Hoon Lee Sang; Alam Khan; Maqbool Muhammad; Khan Gulzar

    2012-01-01

    The purpose of this work is to study dose non-linearity in medical linear accelerators used in conventional radiotherapy and intensity-modulated radiation therapy. Open fields, as well as the enhanced dynamic wedge ones, were used to collect data for 6 MV and 15 MV photon beams obtained from the VARIAN linear accelerator. Beam stability was checked and confirmed for different dose rates, energies, and application of enhanced dynamic wedge by calculating the charge per monitor unit. Moni...

  5. Acute toxicity in comprehensive head and neck radiation for nasopharynx and paranasal sinus cancers: cohort comparison of 3D conformal proton therapy and intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    McDonald, Mark W.; Liu, Yuan; Moore, Michael G.; Johnstone, Peter A. S.

    2016-01-01

    To evaluate acute toxicity endpoints in a cohort of patients receiving head and neck radiation with proton therapy or intensity modulated radiation therapy (IMRT). Forty patients received comprehensive head and neck radiation including bilateral cervical nodal radiation, given with or without chemotherapy, for tumors of the nasopharynx, nasal cavity or paranasal sinuses, any T stage, N0-2. Fourteen received comprehensive treatment with proton therapy, and 26 were treated with IMRT, either comprehensively or matched to proton therapy delivered to the primary tumor site. Toxicity endpoints assessed included g-tube dependence at the completion of radiation and at 3 months after radiation, opioid pain medication requirement compared to pretreatment normalized as equivalent morphine dose (EMD) at completion of treatment, and at 1 and 3 months after radiation. In a multivariable model including confounding variables of concurrent chemotherapy and involved nodal disease, comprehensive head and neck radiation therapy using proton therapy was associated with a lower opioid pain requirement at the completion of radiation and a lower rate of gastrostomy tube dependence by the completion of radiation therapy and at 3 months after radiation compared to IMRT. Proton therapy was associated with statistically significant lower mean doses to the oral cavity, esophagus, larynx, and parotid glands. In subgroup analysis of 32 patients receiving concurrent chemotherapy, there was a statistically significant correlation with a greater opioid pain medication requirement at the completion of radiation and both increasing mean dose to the oral cavity and to the esophagus. Proton therapy was associated with significantly reduced radiation dose to assessed non-target normal tissues and a reduced rate of gastrostomy tube dependence and opioid pain medication requirements. This warrants further evaluation in larger studies, ideally with patient-reported toxicity outcomes and quality of life

  6. Inter fractional dose variation during intensity-modulated radiation therapy for cervical cancer assessed by weekly CT evaluation

    International Nuclear Information System (INIS)

    Han, Youngyih; Shin, Eun Hyuk; Huh, Seung Jae; Lee, Jung Eun; Park, Won

    2006-01-01

    Purpose: To investigate the inter fractional dose variation of a small-bowel displacement system (SBDS)-assisted intensity-modulated radiation therapy (IMRT) for the treatment of cervical cancer. Methods: Four computed tomography (CT) scans were carried out in 10 patients who received radiotherapy for uterine cervical cancer. The initial CT was taken by use of the SBDS, before the beginning of radiotherapy, and 3 additional CT scans with the SBDS were done in subsequent weeks. IMRT was planned by use of the initial CT, and the subsequent images were fused with the initial CT set. Dose-volume histogram (DVH) changes of the targets (planning target volume [PTV] = clinical target volume [CTV] + 1.5 cm) and of the critical organs were evaluated after obtaining the volumes of each organ on 4 CT sets. Results: No significant differences were found in PTV volumes. Changes on the DVH of the CTVs were not significant, whereas DVH changes of the PTVs at 40% to 100% of the prescription dose level were significant (V 90% ; 2nd week: p = 0.0091, 3rd week: p = 0.0029, 4th week: p = 0.0050). The changes in the small-bowel volume included in the treatment field were significant. These were 119.5 cm 3 (range, 26.9-251.0 cm 3 ), 126 cm 3 (range, 38.3-336 cm 3 ), 161.9 cm 3 (range, 37.7-294.6 cm 3 ), and 149.1 cm 3 (range, 38.6-277.8 cm 3 ) at the 1st, 2nd, 3rd, and 4th weeks, respectively, and were significantly correlated with the DVH change in the small bowel, which were significant at the 3rd (V 80% ; p = 0.0230) and 4th (V 80% ; p = 0.0263) weeks. The bladder-volume change correlated to the large volume change (>20%) of the small-bowel volume. Conclusions: Significant DVH differences for the small bowel can result because of interfractional position variations, whereas the DVH differences of the CTV were not significant. Strict bladder-filling control and an accurate margin for the PTV, as well as image-guided position verification, are important to achieve the goal of IMRT

  7. Outcomes and Patterns of Failure for Grade 2 Meningioma Treated With Reduced-Margin Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Press, Robert H. [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Prabhu, Roshan S., E-mail: roshansprabhu@gmail.com [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Appin, Christina L.; Brat, Daniel J. [Department of Pathology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Shu, Hui-Kuo G. [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Hadjipanayis, Constantinos; Olson, Jeffrey J.; Oyesiku, Nelson M. [Department of Neurosurgery, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Curran, Walter J.; Crocker, Ian [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States)

    2014-04-01

    Purpose: The purpose of this study was to evaluate intracranial control and patterns of local recurrence (LR) for grade 2 meningiomas treated with intensity modulated radiation therapy (IMRT) with limited total margin expansions of ≤1 cm. Methods and Materials: We reviewed records of patients with a neuropathological diagnosis of grade 2 meningioma who underwent IMRT at our institution between 2002 and 2012. Actuarial rates were determined by the Kaplan-Meier method from the end of RT. LR was defined as in-field if ≥90% of the recurrence was within the prescription isodose, out-of-field (marginal) if ≥90% was outside of the prescription isodose, and both if neither criterion was met. Results: Between 2002 and 2012, a total of 54 consecutive patients underwent IMRT for grade 2 meningioma. Eight of these patients had total initial margins >1 cm and were excluded, leaving 46 patients for analysis. The median imaging follow-up period was 26.2 months (range, 7-107 months). The median dose for fractionated IMRT was 59.4 Gy (range, 49.2-61.2 Gy). Median clinical target volume (CTV), planning target volume (PTV), and total margin expansion were 0.5 cm, 0.3 cm, and 0.8 cm, respectively. LR occurred in 8 patients (17%), with 2-year and 3-year actuarial local control (LC) of 92% and 74%, respectively. Six of 8 patients (85%) had a known pattern of failure. Five patients (83%) had in-field LR; no patients had marginal LR; and 1 patient (17%) had both. Conclusions: The use of IMRT to treat grade 2 meningiomas with total initial margins (CTV + PTV) ≤1 cm did not appear to compromise outcomes or increase marginal failures compared with other modern retrospective series. Of the 46 patients who had margins ≤1 cm, none experienced marginal failure only. These results demonstrate efficacy and low risk of marginal failure after IMRT treatment of grade 2 meningiomas with reduced margins, warranting study within a prospective clinical trial.

  8. A Prospective Comparison of the Effects of Interfractional Variations on Proton Therapy and Intensity Modulated Radiation Therapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Moteabbed, Maryam, E-mail: mmoteabbed@partners.org; Trofimov, Alexei; Sharp, Gregory C.; Wang, Yi; Zietman, Anthony L.; Efstathiou, Jason A.; Lu, Hsiao-Ming

    2016-05-01

    Purpose: To quantify and compare the impact of interfractional setup and anatomic variations on proton therapy (PT) and intensity modulated radiation therapy (IMRT) for prostate cancer. Methods and Materials: Twenty patients with low-risk or intermediate-risk prostate cancer randomized to receive passive-scattering PT (n=10) and IMRT (n=10) were selected. For both modalities, clinical treatment plans included 50.4 Gy(RBE) to prostate and proximal seminal vesicles, and prostate-only boost to 79.2 Gy(RBE) in 1.8 Gy(RBE) per fraction. Implanted fiducials were used for prostate localization and endorectal balloons were used for immobilization. Patients in PT and IMRT arms received weekly computed tomography (CT) and cone beam CT (CBCT) scans, respectively. The planned dose was recalculated on each weekly image, scaled, and mapped onto the planning CT using deformable registration. The resulting accumulated dose distribution over the entire treatment course was compared with the planned dose using dose-volume histogram (DVH) and γ analysis. Results: The target conformity index remained acceptable after accumulation. The largest decrease in the average prostate D{sub 98} was 2.2 and 0.7 Gy for PT and IMRT, respectively. On average, the mean dose to bladder increased by 3.26 ± 7.51 Gy and 1.97 ± 6.84 Gy for PT and IMRT, respectively. These values were 0.74 ± 2.37 and 0.56 ± 1.90 for rectum. Differences between changes in DVH indices were not statistically significant between modalities. All volume indices remained within the protocol tolerances after accumulation. The average pass rate for the γ analysis, assuming tolerances of 3 mm and 3%, for clinical target volume, bladder, rectum, and whole patient for PT/IMRT were 100/100, 92.6/99, 99.2/100, and 97.2/99.4, respectively. Conclusion: The differences in target coverage and organs at risk dose deviations for PT and IMRT were not statistically significant under the guidelines of this protocol.

  9. Effect of Intensity Modulated Radiation Therapy With Concurrent Chemotherapy on Survival for Patients With Cervical Esophageal Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    McDowell, Lachlan J.; Huang, Shao Hui [Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada); Xu, Wei; Che, Jiahua [Department of Biostatistics, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada); Wong, Rebecca K.S.; Brierley, James; Kim, John; Cummings, Bernard; Waldron, John; Bayley, Andrew [Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada); Hansen, Aaron [Division of Medical Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada); Witterick, Ian [Department of Otolaryngology–Head and Neck Surgery, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada); Ringash, Jolie, E-mail: jolie.ringash@rmp.uhn.ca [Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada)

    2017-05-01

    Purpose: We evaluated the effect of consecutive protocols on overall survival (OS) for cervical esophageal carcinoma (CEC). Methods and Materials: All CEC cases that received definitive radiation therapy (RT) with or without chemotherapy from 1997 to 2013 in 3 consecutive protocols were reviewed. Protocol 1 (P1) consisted of 2-dimensional RT of 54 Gy in 20 fractions with 5-fluorouracil plus either mitomycin C or cisplatin. Protocol 2 (P2) consisted of 3-dimensional conformal RT (3DRT) of ≥60 Gy in 30 fractions plus elective nodal irradiation plus cisplatin. Protocol 3 (P3) consisted of intensity modulated RT (IMRT) of ≥60 Gy in 30 fractions plus elective nodal irradiation plus cisplatin. Multivariable analyses were used to assess the effect of the treatment protocol, RT technique, and RT dose on OS, separately. Results: Of 81 cases (P1, 21; P2, 23; and P3, 37), 34 local (P1, 11 [52%]; P2, 12 [52%]; and P3, 11 [30%]), 16 regional (P1, 6 [29%]); P2, 3 [13%]; and P3, 7 [19%]), and 34 distant (P1, 10 [48%]; P2, 9 [39%]; and P3, 15 [41%]) failures were identified. After adjusting for age (P=.49) and chemotherapy (any vs none; hazard ratio [HR] 0.5, 95% confidence interval [CI] 0.3-0.9; P=.023), multivariable analysis showed P3 had improved OS compared with P1 (HR 0.4, 95% CI 0.2-0.8; P=.005), with a trend shown for benefit compared with P2 (HR 0.6, 95% CI 0.3-1.0; P=.061). OS between P1 and P2 did not differ (P=.29). Analyzed as a continuous variable, higher RT doses were associated with a borderline improved OS (HR 0.97, 95% CI 0.95-1.0; P=.075). IMRT showed improved OS compared with non-IMRT (HR 0.57, 95% CI 0.3-0.8; P=.008). Conclusions: The present retrospective consecutive cohort study showed improved OS with our current protocol (P3; high-dose IMRT with concurrent high-dose cisplatin) compared with historical protocols. The outcomes for patients with CEC remain poor, and novel approaches to improve the therapeutic ratio are warranted.

  10. PET/CT-guided dose-painting versus CT-based intensity modulated radiation therapy in locoregional advanced nasopharyngeal carcinoma.

    Science.gov (United States)

    Liu, Feng; Xi, Xu-Ping; Wang, Hui; Han, Ya-Qian; Xiao, Feng; Hu, Ying; He, Qian; Zhang, Lin; Xiao, Qin; Liu, Lin; Luo, Le; Li, Yun; Mo, Yi; Ma, Hong-Zhi

    2017-01-13

    The effect of 18 F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT)-guided dose-painting intensity-modulated radiation therapy (IMRT) in locoregionally advanced nasopharyngeal carcinoma (NPC) is unclear. This study aimed to assess the efficacy and toxicity of such combination. From 2012 to 2014, 213 patients with stage III-IVB NPC received chemoradiotherapy by PET/CT-guided DP-IMRT (group A, n = 101) or CT-based IMRT (group B, n = 112). In group A, subvolume GTVnx- PET (gross tumor volume of nasopharynx in PET images) was defined within GTVnx (gross tumor volume of nasopharynx) as the SUV50%max isocontour; the dose to GTVnx- PET was escalated to DT 75.2 Gy/32 and 77.55 Gy/33 Fx, respectively, for patients with T1-2 and T3-4 disease, respectively. In group B, PGTVnx was irradiated at DT 70.4-72.6 Gy/32-33 Fx in 2.2 Gy per fraction. Complete response rates were 99.0% (100/101) and 92.9% (104/112) in groups A and B, respectively (P = 0.037). Compared with CT-based IMRT, FDG-PET/CT guided DP-IMRT significantly improved 3-year local failure-free survival (LFFS, 98.8% vs. 91.3%; P = 0.032), locoregional failure-free survival (LRFFS, 97.2 vs. 91.2%; P = 0.049), distant metastasis-free survival (DMFS, 92.9% vs. 87.4%; P = 0.041), disease free survival (DFS, 87.9% vs. 82.4%; P = 0.02), and overall survival (OS, 91.8% vs. 82.6%; P = 0.049). No statistically significant differences in acute and late toxic effects were observed. Multivariate analysis showed that dose painting (PET/CT-guided DP-IMRT vs CT-based IMRT without DP) was a significant independent prognostic factor for LFFS and DFS. FDG-PET/CT guided DP-IMRT plus chemotherapy is associated with a considerable survival benefit, without increasing toxicity in patients with locoregional advanced NPC. Further randomized trials are needed to fully assess the role of PET/CT-guided DP-IMRT.

  11. The use of biologically related model (Eclipse for the intensity-modulated radiation therapy planning of nasopharyngeal carcinomas.

    Directory of Open Access Journals (Sweden)

    Monica W K Kan

    Full Text Available Intensity-modulated radiation therapy (IMRT is the most common treatment technique for nasopharyngeal carcinoma (NPC. Physical quantities such as dose/dose-volume parameters are used conventionally for IMRT optimization. The use of biological related models has been proposed and can be a new trend. This work was to assess the performance of the biologically based IMRT optimization model installed in a popular commercial treatment planning system (Eclipse as compared to its dose/dose volume optimization model when employed in the clinical environment for NPC cases.Ten patients of early stage NPC and ten of advanced stage NPC were selected for this study. IMRT plans optimized using biological related approach (BBTP were compared to their corresponding plans optimized using the dose/dose volume based approach (DVTP. Plan evaluation was performed using both biological indices and physical dose indices such as tumor control probability (TCP, normal tissue complication probability (NTCP, target coverage, conformity, dose homogeneity and doses to organs at risk. The comparison results of the more complex advanced stage cases were reported separately from those of the simpler early stage cases.The target coverage and conformity were comparable between the two approaches, with BBTP plans producing more hot spots. For the primary targets, BBTP plans produced comparable TCP for the early stage cases and higher TCP for the advanced stage cases. BBTP plans reduced the volume of parotid glands receiving doses of above 40 Gy compared to DVTP plans. The NTCP of parotid glands produced by BBTP were 8.0 ± 5.8 and 7.9 ± 8.7 for early and advanced stage cases, respectively, while those of DVTP were 21.3 ± 8.3 and 24.4 ± 12.8, respectively. There were no significant differences in the NTCP values between the two approaches for the serial organs.Our results showed that the BBTP approach could be a potential alternative approach to the DVTP approach for NPC.

  12. Dose-volume histogram comparison between static 5-field IMRT with 18-MV X-rays and helical tomotherapy with 6-MV X-rays.

    Science.gov (United States)

    Hayashi, Akihiro; Shibamoto, Yuta; Hattori, Yukiko; Tamura, Takeshi; Iwabuchi, Michio; Otsuka, Shinya; Sugie, Chikao; Yanagi, Takeshi

    2015-03-01

    We treated prostate cancer patients with static 5-field intensity-modulated radiation therapy (IMRT) using linac 18-MV X-rays or tomotherapy with 6-MV X-rays. As X-ray energies differ, we hypothesized that 18-MV photon IMRT may be better for large patients and tomotherapy may be more suitable for small patients. Thus, we compared dose-volume parameters for the planning target volume (PTV) and organs at risk (OARs) in 59 patients with T1-3 N0M0 prostate cancer who had been treated using 5-field IMRT. For these same patients, tomotherapy plans were also prepared for comparison. In addition, plans of 18 patients who were actually treated with tomotherapy were analyzed. The evaluated parameters were homogeneity indicies and a conformity index for the PTVs, and D2 (dose received by 2% of the PTV in Gy), D98, Dmean and V10-70 Gy (%) for OARs. To evaluate differences by body size, patients with a known body mass index were grouped by that index ( 25 kg/m(2)). For the PTV, all parameters were higher in the tomotherapy plans compared with the 5-field IMRT plans. For the rectum, V10 Gy and V60 Gy were higher, whereas V20 Gy and V30 Gy were lower in the tomotherapy plans. For the bladder, all parameters were higher in the tomotherapy plans. However, both plans were considered clinically acceptable. Similar trends were observed in 18 patients treated with tomotherapy. Obvious trends were not observed for body size. Tomotherapy provides equivalent dose distributions for PTVs and OARs compared with 18-MV 5-field IMRT. Tomotherapy could be used as a substitute for high-energy photon IMRT for prostate cancer regardless of body size. © The Author 2015. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  13. Change in volumes and radiation doses of parotid and submandibular glands during intensity modulated radiation therapy (IMRT) for nasopharyngeal carcinoma

    OpenAIRE

    Ho, PPY; Kwong, DLW; Au, GKH; Leung, TW; Lee, V; Ng, SCY

    2011-01-01

    OBJECTIVES: To investigate the changes in volumes and radiation doses to parotid and submandibular glands during IMRT for nasopharyngeal carcinoma in an attempt to justify re-planning in the mid-course of IMRT to minimize radiation-induced xerostomia. MATERIALS AND METHODS: 33 consecutive patients with stage III to stage IVB nasopharyngeal carcinoma (AJCC Staging Manual 6th Edition) who received concurrent chemoradiation were included in this study. Computed tomography (CT) scans were perform...

  14. Importance of contouring the cervical spine levels in initial intensity-modulated radiation therapy radiation for head and neck cancers: Implications for re-irradiation

    Directory of Open Access Journals (Sweden)

    Parashar Bhupesh

    2009-01-01

    Full Text Available Aim: To evaluate the maximum differential cervical spinal (C-spine cord dose in intensity-modulated radiation therapy (IMRT plans of patients undergoing radiotherapy for treatment of head and neck cancer. Materials and Methods: The C-spine of ten head and neck cancer patients that were planned using IMRT and each cervical vertebral body and the right and left sides was contoured by splitting the cord in the center. Dose-volume histograms (DVH and maximum point doses were obtained for each contour and compared. Results: The dose to the cord varied with the location of the primary tumor but such variation was not consistently seen. This report provides information that is critical for planning reirradiation treatments. We recommend that contouring of the C-spine cord with IMRT should include outlining of each cervical cord level and identification of the right and the left sides of the cord on each plan.

  15. Intensity-modulated radiation treatment for head-and-neck squamous cell carcinoma-the University of Iowa experience

    International Nuclear Information System (INIS)

    Yao Min; Dornfeld, Kenneth J.; Buatti, John M.; Skwarchuk, Mark; Tan Huaming; Nguyen, Thanh; Wacha, Judith C.; Bayouth, John E.; Funk, Gerry F.; Smith, Russell B.; Graham, Scott M.; Chang, Kristi; Hoffman, Henry T.

    2005-01-01

    Purpose: To review the University of Iowa experience with intensity-modulated radiotherapy (IMRT) in the treatment of head-and-neck squamous cell carcinoma. Methods and Materials: From October 1999 to April 2004, 151 patients with head-and-neck squamous cell carcinoma were treated with IMRT for curative intent. One patient was lost to follow-up 2 months after treatment and therefore excluded from analysis. Of the remaining 150 patients, 99 were treated with definitive IMRT, and 51 received postoperative IMRT. Sites included were nasopharynx, 5; oropharynx, 56; larynx, 33; oral cavity, 29; hypopharynx, 8; nasal cavity/paranasal sinus, 8; and unknown primary, 11. None of the patients treated with postoperative IMRT received chemotherapy. Of 99 patients who had definitive IMRT, 68 patients received concurrent cisplatin-based chemotherapy. One patient received induction cisplatin-based chemotherapy, but no concurrent chemotherapy was given. Three clinical target volumes (CTV1, CTV2, and CTV3) were defined. The prescribed doses to CTV1, CTV2, and CTV3 in the definitive cohort were 70-74 Gy, 60 Gy, and 54 Gy, respectively. For high-risk postoperative IMRT, the prescribed doses to CTV1, CTV2, and CTV3 were 64-66 Gy, 60 Gy, and 54 Gy, respectively. For intermediate-risk postoperative IMRT, the prescribed doses to CTV1, CTV2, and CTV3 were 60 Gy, 60 Gy, and 54 Gy. Results: The median follow-up was 18 months (range, 2-60 months). All living patients were followed for at least 6 months. There were 11 local-regional failures: 7 local failures, 3 regional failures, and 1 failure both in the primary tumor and regional lymph node. There were 16 patients who failed distantly, either with distant metastasis or new lung primaries. The 2-year overall survival, local progression-free survival, locoregional progression-free survival, and distant disease-free survival rates were 85%, 94%, 92%, and 87%, respectively. The median time from treatment completion to local-regional recurrence

  16. Impact of intravenous contrast used in computed tomography on radiation dose to carotid arteries and thyroid in intensity-modulated radiation therapy planning for nasopharyngeal carcinoma.

    Science.gov (United States)

    Lee, Victor Ho Fun; Ng, Sherry Chor Yi; Kwong, Dora Lai Wan; Lam, Ka On; Leung, To Wai

    2017-01-01

    The aim of this study was to investigate if intravenous contrast injection affected the radiation doses to carotid arteries and thyroid during intensity-modulated radiation therapy (IMRT) planning for nasopharyngeal carcinoma (NPC). Thirty consecutive patients with NPC underwent plain computed tomography (CT) followed by repeated scanning after contrast injection. Carotid arteries (common, external, internal), thyroid, target volumes, and other organs-at-risk (OARs), as well as IMRT planning, were based on contrast-enhanced CT (CE-CT) images. All these structures and the IMRT plans were then copied and transferred to the non-contrast-enhanced CT (NCE-CT) images, and dose calculation without optimization was performed again. The radiation doses to the carotid arteries and the thyroid based on CE-CT and NCE-CT were then compared. Based on CE-CT, no statistical differences, despite minute numeric decreases, were noted in all dosimetric parameters (minimum, maximum, mean, median, D05, and D01) of the target volumes, the OARs, the carotid arteries, and the thyroid compared with NCE-CT. Our results suggested that compared with NCE-CT planning, CE-CT scanning should be performed during IMRT for better target and OAR delineation, without discernible change in radiation doses. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  17. Local Setup Reproducibility of the Spinal Column When Using Intensity-Modulated Radiation Therapy for Craniospinal Irradiation With Patient in Supine Position

    Energy Technology Data Exchange (ETDEWEB)

    Stoiber, Eva Maria, E-mail: eva.stoiber@med.uni-heidelberg.de [Department of Radiation Oncology, University Hospital Heidelberg, Heidelberg (Germany); Department of Medical Physics, German Cancer Research Center, Heidelberg (Germany); Giske, Kristina [Department of Medical Physics, German Cancer Research Center, Heidelberg (Germany); Schubert, Kai; Sterzing, Florian; Habl, Gregor; Uhl, Matthias; Herfarth, Klaus [Department of Radiation Oncology, University Hospital Heidelberg, Heidelberg (Germany); Bendl, Rolf [Department of Medical Physics, German Cancer Research Center, Heidelberg (Germany); Medical Informatics, Heilbronn University, Heilbronn (Germany); Debus, Juergen [Department of Radiation Oncology, University Hospital Heidelberg, Heidelberg (Germany)

    2011-12-01

    Purpose: To evaluate local positioning errors of the lumbar spine during fractionated intensity-modulated radiotherapy of patients treated with craniospinal irradiation and to assess the impact of rotational error correction on these uncertainties for one patient setup correction strategy. Methods and Materials: 8 patients (6 adults, 2 children) treated with helical tomotherapy for craniospinal irradiation were retrospectively chosen for this analysis. Patients were immobilized with a deep-drawn Aquaplast head mask. Additionally to daily megavoltage control computed tomography scans of the skull, once-a-week positioning of the lumbar spine was assessed. Therefore, patient setup was corrected by a target point correction, derived from a registration of the patient's skull. The residual positioning variations of the lumbar spine were evaluated applying a rigid-registration algorithm. The impact of different rotational error corrections was simulated. Results: After target point correction, residual local positioning errors of the lumbar spine varied considerably. Craniocaudal axis rotational error correction did not improve or deteriorate these translational errors, whereas simulation of a rotational error correction of the right-left and anterior-posterior axis increased these errors by a factor of 2 to 3. Conclusion: The patient fixation used allows for deformations between the patient's skull and spine. Therefore, for the setup correction strategy evaluated in this study, generous margins for the lumbar spinal target volume are needed to prevent a local geographic miss. With any applied correction strategy, it needs to be evaluated whether or not a rotational error correction is beneficial.

  18. Three Cases of Radiation-Induced Hepatitis B Virus Reactivation after Hepatic Tomotherapy: Case Report

    International Nuclear Information System (INIS)

    Kong, Moon Kyoo; Hong, Seong Eon; Kim, Byung Ho; Choi, Jin Hyun

    2011-01-01

    Radiation-induced liver disease (RILD) has been characterized as a veno-occlusive disease with anicteric elevation of alkaline phosphatase (ALP). However, some RILD patients present with elevated transaminase levels rather than with anicteric elevation of ALP, and these findings are common in the Asia-Pacific region where hepatitis B virus (HBV) infection is associated with 70-90% of hepatocelluar carcinoma (HCC) cases. In addition, the development of RILD is more common in patients with hepatitis B virus-related HCC. These findings indicate that susceptibility to RILD might be different in HBV carriers and non-carriers, and moreover, RILD in patients with HBV-related HCC might be associated with another unique pathogenesis such as HBV reactivation. However, HBV reactivation after hepatic irradiation has been reported in only a few studies. This study reports three cases of HBV reactivation after hepatic tomotherapy for management of HCC.

  19. Three Cases of Radiation-Induced Hepatitis B Virus Reactivation after Hepatic Tomotherapy: Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Moon Kyoo; Hong, Seong Eon; Kim, Byung Ho; Choi, Jin Hyun [Kyung Hee University College of Medicine, Seoul (Korea, Republic of)

    2011-03-15

    Radiation-induced liver disease (RILD) has been characterized as a veno-occlusive disease with anicteric elevation of alkaline phosphatase (ALP). However, some RILD patients present with elevated transaminase levels rather than with anicteric elevation of ALP, and these findings are common in the Asia-Pacific region where hepatitis B virus (HBV) infection is associated with 70-90% of hepatocelluar carcinoma (HCC) cases. In addition, the development of RILD is more common in patients with hepatitis B virus-related HCC. These findings indicate that susceptibility to RILD might be different in HBV carriers and non-carriers, and moreover, RILD in patients with HBV-related HCC might be associated with another unique pathogenesis such as HBV reactivation. However, HBV reactivation after hepatic irradiation has been reported in only a few studies. This study reports three cases of HBV reactivation after hepatic tomotherapy for management of HCC.

  20. The effect of partially used high energy photon on intensity-modulated radiation therapy plan for head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Nam Joon; Seok, Jin Yong; Won, Hui Su; Hong, Joo Wan; Choi, Ji Hun; Park, Jin Hong [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2013-03-15

    A selection of proper energy in treatment planning is very important because of having different dose distribution in body as photon energy. In generally, the low energy photon has been used in intensity-modulated radiation therapy (IMRT) for head and neck (H and N) cancer. The aim of this study was to evaluate the effect of partially used high energy photon at posterior oblique fields on IMRT plan for H and N cancer. The study was carried out on 10 patients (nasopharyngeal cancer 5, tonsilar cancer 5) treated with IMRT in Seoul National University Bundang Hospital. CT images were acquired 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). Two plans were generated under same planing objectives, dose volume constraints, and eight fields setting: (1) The low energy plan (LEP) created using 6 MV beam alone, (2) the partially used high energy plan (PHEP) created partially using 15 MV beam at two posterior oblique fields with deeper penetration depths, while 6 MV beam was used at the rest of fields. The plans for LEP and PHEP were compared in terms of coverage, conformity index (CI) and homogeneity index (HI) for planning target volume (PTV). For organs at risk (OARs), D{sub mean} and D{sub 50%} were analyzed on both parotid glands and D{sub max}, D{sub 1%} for spinal cord were analyzed. Integral dose (ID) and total monitor unit (MU) were compared as addition parameters. For the comparing dose to normal tissue of posterior neck, the posterior-normal tissue volume (P-NTV) was set on the patients respectively. The D{sub mean}, V{sub 20Gy} and V{sub 25Gy} for P-NTV were evaluated by using dose volume histogram (DVH). The dose distributions were similar with regard to coverage, CI and HI for PTV between the LEP and PHEP. No evident difference was observed in the spinal cord. However, the D{sub mean}, D{sub 50%} for both parotid gland were slightly reduced by 0.6%, 0.7% in PHEP. The ID was reduced by 1

  1. Intensity-modulated radiation therapy for head and neck cancers with bilateral irradiation of the neck: preliminary results

    International Nuclear Information System (INIS)

    Lapeyre, M.; Mege, A.; Mege, P.; Racadot, S.; Marchal, C.; Marchesi, V.; Aletti, P.; Noel, A.; Marchesi, V.; Aletti, P.; Noel, A.; Marchal, C.

    2004-01-01

    Purpose. - To report preliminary results of a prospective study of intensity-modulated radiotherapy (IMRT) for head and neck squamous cell carcinoma (HNC) with bilateral irradiation of the neck. Patients and methods. - At the Alexis Vautrin Cancer Center, 23 patients have been treated with IMRT for HNC since January 2002-August 2003. The first 10 patients with a minimum follow-up of 3 months were analyzed. All tumors were oropharyngeal. There were four females and six males, with a mean age of 50 years (range 39-66). Stages were I-II in eight and III-IV in two. CTV1 was microscopic disease and N0 neck (prescribed dose: 50 Gy) and CTV2 was macroscopic disease and the volume at risk (prescribed dose: 66-70 Gy). PTV were CTV + 5 mm. Patient's immobilization consisted of a five-point head neck shoulder thermoplastic mask. Set-up verifications were done by semi-automatically matching portal images and digitized reconstructed radiographs. IMRT used dynamic multi-leaf collimation. Five patients (group A) received 50 Gy IMRT (two post-operative and three with a brachytherapy boost with a mean dose: 27.5 Gy), and five patients (group B) received 66-70 Gy IMRT (four post-operative). Acute and late normal tissue effects were graded according to the RTOG-EORTC radiation morbidity scoring criteria. Results. - With a median follow-up of 7.4 months (range 3-18.5), no patient died or had loco-regional relapse. The displacements were <4 mm in 98% cases. CTV1 and 2 received 95% of the prescribed dose in 100% of the volume. On average the mean dose to the contralateral parotid was 25.5 Gy for group A vs. 31 Gy for group B (P = 0.09). Mean doses <26 Gy were obtained in three of five patients in group A vs. zero of five patients in group B (P = 0.04). Acute skin toxicities were grade 1 in five patients, grade 2 in four and grade 3 in one. Acute mucositis cases were grade 1 in three patients, grade 2 in five and localized grade 3 in two. At 3 months, 50% of the patients had a grade 0

  2. A Phase II Study of Intensity Modulated Radiation Therapy to the Pelvis for Postoperative Patients With Endometrial Carcinoma: Radiation Therapy Oncology Group Trial 0418

    Energy Technology Data Exchange (ETDEWEB)

    Jhingran, Anuja, E-mail: ajhingra@mdanderson.org [University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Winter, Kathryn [RTOG Statistical Center, Philadelphia, Pennsylvania (United States); Portelance, Lorraine [University of Miami, Miami, Florida (United States); Miller, Brigitte [Carolinas Medical Center North East, Concord, North Carolina (United States); Salehpour, Mohammad [University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Gaur, Rakesh [St. Luke' s Hospital, Kansas City, Missouri (United States); Souhami, Luis [McGill University Health Centre, Montreal, Quebec (Canada); Small, William [Robert H. Lurie Comprehensive Cancer Center of Northwestern University, Chicago, Illionis (United States); Berk, Lawrence [H. Lee Moffitt Cancer Center, Tampa, Florida (United States); Gaffney, David [Huntsman Cancer Hospital, Salt Lake City, Utah (United States)

    2012-09-01

    Purpose: To determine the feasibility of pelvic intensity modulated radiation therapy (IMRT) for patients with endometrial cancer in a multi-institutional setting and to determine whether this treatment is associated with fewer short-term bowel adverse events than standard radiation therapy. Methods: Patients with adenocarcinoma of the endometrium treated with pelvic radiation therapy alone were eligible. Guidelines for target definition and delineation, dose prescription, and dose-volume constraints for the targets and critical normal structures were detailed in the study protocol and a web-based atlas. Results: Fifty-eight patients were accrued by 25 institutions; 43 were eligible for analysis. Forty-two patients (98%) had an acceptable IMRT plan; 1 had an unacceptable variation from the prescribed dose to the nodal planning target volume. The proportions of cases in which doses to critical normal structures exceeded protocol criteria were as follows: bladder, 67%; rectum, 76%; bowel, 17%; and femoral heads, 33%. Twelve patients (28%) developed grade {>=}2 short-term bowel adverse events. Conclusions: Pelvic IMRT for endometrial cancer is feasible across multiple institutions with use of a detailed protocol and centralized quality assurance (QA). For future trials, contouring of vaginal and nodal tissue will need continued monitoring with good QA and better definitions will be needed for organs at risk.

  3. Hematologic Toxicity in Patients Treated With Postprostatectomy Whole-Pelvis Irradiation With Different Intensity Modulated Radiation Therapy Techniques Is Not Negligible and Is Prolonged: Preliminary Results of a Longitudinal, Observational Study

    Energy Technology Data Exchange (ETDEWEB)

    Cozzarini, Cesare, E-mail: cozzarini.cesare@hsr.it [Department of Radiotherapy, San Raffaele Scientific Institute, Milan (Italy); Chiorda, Barbara Noris [Department of Radiotherapy, San Raffaele Scientific Institute, Milan (Italy); Sini, Carla; Fiorino, Claudio [Department of Medical Physics, San Raffaele Scientific Institute, Milan (Italy); Briganti, Alberto; Montorsi, Francesco [Department of Urology, Vita-Salute University, Milan (Italy); Di Muzio, Nadia [Department of Radiotherapy, San Raffaele Scientific Institute, Milan (Italy)

    2016-06-01

    Purpose: To address the thus-far poorly investigated severity and duration of hematologic toxicity from whole-pelvis radiation therapy (WPRT) in a cohort of chemo-naïve patients treated with postprostatectomy radiation therapy including WPRT with different intensity modulated radiation therapy (IMRT) techniques, doses, and fractionations. Methods and Materials: This analysis pertains to 125 patients (70 from a pilot study and 55 from an observational protocol) for whom 1 baseline and at least 3 subsequent blood samples (median 6), obtained at irradiation midpoint and end, and thereafter at 3, 6, and 12 months, were available. Patients were treated with adjuvant (n=73) or salvage intent; static-field IMRT (n=19); volumetric modulated arc therapy (n=60) or helical Tomotherapy (n=46); and conventional (n=39) or moderately hypofractionated (median 2.35 Gy per fraction, n=86) regimens. The median 2-Gy equivalent dose (EQD2) to the prostatic bed was 70.4 Gy with a lymph-nodal planning target volume of 50.2 Gy. Clinical and dosimetric data were collected. Results: Both leukopenia and thrombocytopenia were significant (median nadir count 65% and 67% of baseline, respectively), with leukopenia also persisting (1-year median count 75% of baseline). Lymphopenia was the major contributor to the severity and 1-year persistence of leukopenia; all patients developed acute grade ≥1 lymphopenia (61% and 26% grade 2 and ≥3, respectively), whereas 1-year grade ≥2 lymphopenia was still present in 16%. In addition to an independent predictive role of corresponding baseline values, multivariable analyses highlighted that higher EQD2 doses to lymph nodal planning target volume increased risk of acute neutropenia and hypofractionation for acute thrombocytopenia. Of note, patients of older age were at higher risk for acute grade 2 lymphopenia, and interestingly, increased risk of grade >2 lymphopenia for those who smoked at least one year. No role for different IMRT techniques

  4. A comparison of radiation treatment techniques for carcinomas of the larynx and hypopharynx using 3-D dose distributions and intensity modulation

    International Nuclear Information System (INIS)

    Morris, David; Miller, Elizabeth P.; Rosenman, Julian; Sailer, Scott; Tepper, Joel

    1997-01-01

    Purpose/Objective: Patients with carcinomas of the larynx and hypopharynx often cannot be treated effectively with a lateral/low anterior neck combination because the midline block will cover the tumor bed. Common alternatives to this approach often produce serious dose inhomogeneities. Our study was to determine whether modern 3D treatment planning techniques with intensity modulation could overcome these dose inhomogeneities and also allow us to omit the problematic posterior neck electron boost which often gives poor nodal coverage. Materials and Methods: Dose distribution studies were performed on patients who had received post-operative radiation following laryngectomy for advanced staged cancer. The clinical tumor volume or CTV (surgical bed and at-risk nodal stations) was defined on planning CT images. Four commonly used alternative plans, the MGH 'minimantle', 'kicked-out' laterals, the University of Florida 3-field, and a standard 3 field with a lateral cord block were evaluated using the Plan UNC (PLUNC) treatment planning software. New plans that might also preclude the use of posterior neck electrons were also evaluated. The plans were then intensity modulated to reduce the well known cold spots as described previously in IJROBP August 1991, Vol. 21, No. 3. All dose distributions were evaluated for dose homogeneity, minimum and maximum CTV dose, and dose to normal critical structures. The inhomogeneities were determined using standard dose-volume histogram (DVH) techniques but positional information was gathered by dividing the CTV into sensible anatomic regions and studying the DVH for each separately. Results: For the mini-mantle approach, intensity modulation substantially improved the dose inhomogeneities but did not affect the minimum CTV dose and had no effect on the cord dose. Intensity modulation decreased the maximum CTV dose (110% vs. 130%) but had the undesirable effect of lessening the dose difference between cord and CTV. For the kicked

  5. Advances in radiotherapy techniques and delivery for non-small cell lung cancer: benefits of intensity-modulated radiation therapy, proton therapy, and stereotactic body radiation therapy.

    Science.gov (United States)

    Diwanji, Tejan P; Mohindra, Pranshu; Vyfhuis, Melissa; Snider, James W; Kalavagunta, Chaitanya; Mossahebi, Sina; Yu, Jen; Feigenberg, Steven; Badiyan, Shahed N

    2017-04-01

    The 21st century has seen several paradigm shifts in the treatment of non-small cell lung cancer (NSCLC) in early-stage inoperable disease, definitive locally advanced disease, and the postoperative setting. A key driver in improvement of local disease control has been the significant evolution of radiation therapy techniques in the last three decades, allowing for delivery of definitive radiation doses while limiting exposure of normal tissues. For patients with locally-advanced NSCLC, the advent of volumetric imaging techniques has allowed a shift from 2-dimensional approaches to 3-dimensional conformal radiation therapy (3DCRT). The next generation of 3DCRT, intensity-modulated radiation therapy and volumetric-modulated arc therapy (VMAT), have enabled even more conformal radiation delivery. Clinical evidence has shown that this can improve the quality of life for patients undergoing definitive management of lung cancer. In the early-stage setting, conventional fractionation led to poor outcomes. Evaluation of altered dose fractionation with the previously noted technology advances led to advent of stereotactic body radiation therapy (SBRT). This technique has dramatically improved local control and expanded treatment options for inoperable, early-stage patients. The recent development of proton therapy has opened new avenues for improving conformity and the therapeutic ratio. Evolution of newer proton therapy techniques, such as pencil-beam scanning (PBS), could improve tolerability and possibly allow reexamination of dose escalation. These new progresses, along with significant advances in systemic therapies, have improved survival for lung cancer patients across the spectrum of non-metastatic disease. They have also brought to light new challenges and avenues for further research and improvement.

  6. A study of the positioning errors of head and neck in the process of intensity modulation radiated therapy of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Lin Chengguang; Lin Liuwen; Liu Bingti; Liu Xiaomao; Li Guowen

    2011-01-01

    Objective: To investigate the positioning errors of head and neck during intensity-modulated radiation therapy of nasopharyngeal carcinoma. Methods: Nineteen patients with middle-advanced nasopharyngeal carcinoma (T 2-4 N 1-3 M 0 ), treated by intensity-modulated radiation therapy, underwent repeated CT during their 6-week treatment course. All the patients were immobilized by head-neck-shoulder thermoplastic mask. We evaluated their anatomic landmark coordinated in a total of 66 repeated CT data sets and respective x, y, z shifts relative to their position in the planning CT. Results: The positioning error of the neck was 2.44 mm ± 2.24 mm, 2.05 mm ± 1.42 mm, 1.83 mm ± 1.53 mm in x, y, z respectively. And that of the head was 1.05 mm ± 0.87 mm, 1.23 mm ± 1.05 mm, 1.17 mm ± 1.55 mm respectively. The positioning error between neck and head have respectively statistical difference (t=-6.58, -5.28, -3.42, P=0.000, 0.000, 0.001). The system error of the neck was 2.33, 1.67 and 1.56 higher than that of the head, respectively in left-right, vertical and head-foot directions; and the random error of neck was 2.57, 1.34 and 0.99 higher than that of head respectively. Conclusions: In the process of the intensity-modulated radiation therapy of nasopharyngeal carcinoma, with the immobilization by head-neck-shoulder thermoplastic mask, the positioning error of neck is higher than that of head. (authors)

  7. Intensity-modulated radiation therapy reduces radiation-induced trismus in patients with nasopharyngeal carcinoma: a prospective study with >5 years of follow-up.

    Science.gov (United States)

    Chen, Yuan-Yuan; Zhao, Chong; Wang, Jin; Ma, Hong-Lian; Lai, Shu-Zheng; Liu, Yuan; Han, Fei; Lu, Li-Xia; Bao, Yong; Chen, Ming

    2011-07-01

    Intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC) provides better temporomandibular joint (TMJ) sparing and, thus, may reduce the incidence of radiation-induced trismus after radiotherapy. The objectives of this study were to evaluate radiation-induced trismus in patients with NPC who had received IMRT and to assess the pretreatment factors, relevant treatment factors, and dosimetry parameters associated with trismus. A prospective, single-arm measurement study with more than 5 years of follow-up was designed. Patients with newly diagnosed stage I through IVB NPC who received treatment with IMRT were eligible. Patients received 66 to 70 grays (Gy) to the gross tumor volume. The maximal interincisal distance (MID) was measured at baseline and 6 months, 1 year, 2 years, 3 years, 4 years, and 5 years after they completed IMRT. The trial enrolled 211 consecutive patients from 2001 to 2004. The mean dose to the TMJ ranged from 6.18 Gy to 51.36 Gy (median dose, 29.88 Gy). Compared with baseline MID levels, normalized MID levels at 6 months, 1 year, 2 years, 3 years, 4 years, and 5 years after IMRT were 94.6% ± 9.9%, 92.5% ± 10.5%, 92% ± 10.6%, 92.2% ± 10.5%, 92.1% ± 10.2%, and 90.3% ± 11.4%, respectively (P trismus was identified in 12 of 211 patients (5.7%), and no grade 3/4 trismus was observed. There was an increasing risk of trismus after IMRT when the MID was 40.5 mm (P = .007). No dosimetric parameter was associated with trismus. IMRT was able to reduce the radiation dose to the TMJ and likely reduced the incidence and severity of radiation-induced trismus after radiotherapy. Copyright © 2011 American Cancer Society.

  8. Conformal avoidance helical tomotherapy for dogs with nasopharyngeal tumors

    International Nuclear Information System (INIS)

    Welsh, J.S.; Turek, M.; Mackie, T.R.; Miller, P.; Mehta, M.P.; Forrest, L.J.

    2003-01-01

    Helical tomotherapy provides a unique means of delivering intensity-modulated radiation therapy (IMRT) using a novel treatment unit, which merges features of a linear accelerator with a helical CT scanner. Thanks to the CT imaging capacity, targeted regions can be visualized prior to, during, or immediately after each treatment. Such image-guidance through megavoltage CT will allow the realization and refinement of the concept of adaptive radiotherapy - the reconstruction of the actually delivered daily dose (as opposed to planned dose) accompanied by prescription adjustments when appropriate. In addition to this unique feature, helical tomotherapy promises further improvements in the specific avoidance of critical normal structures, i.e. conformal avoidance, the counterpart of conformal therapy. The first definitive treatment protocol using helical tomotherapy is presently underway for dogs with nasopharyngeal tumors. In general, such tumors can be treated with conventional external beam radiation therapy but at the cost of severe ocular toxicity due to the anatomy of the canine head. These are readily measurable toxicities and are almost universal in incidence; therefore, the canine nasopharyngeal tumor presents an ideal model to assess the ability to conformally avoid critical structures. It is hoped that conformal avoidance helical tomotherapy will improve tumor control via dose-escalation while reducing ocular toxicity in these veterinary patients. A total of 10 fractions are scheduled for these patients; the first 3 dogs have all received at least 7 fractions delivered via helical tomotherapy. Although preliminary, the first 3 dogs treated have not shown any evidence of ocular toxicity in this ongoing study

  9. Suppression of dark current radiation in step-and-shoot intensity modulated radiation therapy by the initial pulse-forming network

    International Nuclear Information System (INIS)

    Cheng, C.-W.; Das, Indra J.; Ndlovu, Alois M.

    2002-01-01

    The effect of the initial pulse forming network (IPFN) on the suppression of dark current is investigated for a Siemens Primus accelerator. The dark current produces a spurious radiation, which is referred to as dark current radiation (DCR) in this study. In the step-and-shoot delivery of an intensity modulated radiation therapy (IMRT), the DCR could be of some concern for whole body dose along with leakage radiation through collimator jaws or multileaf collimator. By adjusting the IPFN-to-PFN ratio to >0.8, the DCR can be measured with an ion chamber during the 'PAUSE' state of the accelerator in the IMRT mode. For 15 MV x rays, the magnitude of the DCR is approximately equal to 0.7% of the dose at d max for a 10x10 cm 2 field. The DCR has a similar central axis depth dose as a 15 MV beam as determined from a water phantom scan. When the IPFN-to-PFN ratio is lowered to <0.8, no DCR is detected. For low energy x rays (6 MV), no DCR is detected regardless of the IPFN-to-PFN ratio. Although the DCR is studied only for the Siemens Primus model accelerator, the same precaution applies to other models of modern accelerators from other vendors. Due to the large number of field segments used in a step-and-shoot IMRT, it is imperative therefore, that dark current evaluation be part of machine commissioning and annual calibration for high-energy photon beams. Should DCR be detected, the medical physicist should work with a service engineer to rectify the problem. In view of DCR and whole body dose, low-energy photon beams are advisable for IMRT

  10. Comparison of dose-volume histograms for Tomo therapy, linear accelerator-based 3D conformal radiation therapy, and intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Ji, Youn-Sang; Dong, Kyung-Rae; Kim, Chang-Bok; Choi, Seong-Kwan; Chung, Woon-Kwan; Lee, Jong-Woong

    2011-01-01

    Highlights: → Evaluation of DVH from 3D CRT, IMRT and Tomo therapy was conducted for tumor therapy. → The doses of GTV and CTV were compared using DVHs from 3D CRT, IMRT and Tomo therapy. → The GTV was higher when Tomo therapy was used, while the doses of critical organ were low. → They said that Tomo therapy satisfied the goal of radiation therapy more than the others. - Abstract: Evaluation of dose-volume histograms from three-dimensional conformal radiation therapy (3D CRT), intensity-modulated radiation therapy (IMRT), and Tomo therapy was conducted. These three modalities are among the diverse treatment systems available for tumor therapy. Three patients who received tumor therapy for a malignant oligodendroglioma in the cranium, nasopharyngeal carcinoma in the cervical neck, and prostate cancer in the pelvis were selected as study subjects. Therapy plans were made for the three patients before dose-volume histograms were obtained. The doses of the gross tumor volume (GTV) and the clinical target volume (CTV) were compared using the dose-volume histograms obtained from the LINAC-based 3D CRT, IMRT planning station (Varian Eclipse-Varian, version 8.1), and Tomo therapy planning station. In addition, the doses of critical organs in the cranium, cervix, and pelvis that should be protected were compared. The GTV was higher when Tomo therapy was used compared to 3D CRT and the LINAC-based IMRT, while the doses of critical organ tissues that required protection were low. These results demonstrated that Tomo therapy satisfied the ultimate goal of radiation therapy more than the other therapies.

  11. Three-Dimensional Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Combined With Transcatheter Arterial Chemoembolization for Locally Advanced Hepatocellular Carcinoma: An Irradiation Dose Escalation Study

    International Nuclear Information System (INIS)

    Ren Zhigang; Zhao Jiandong; Gu Ke; Chen Zhen; Lin Junhua; Xu Zhiyong; Hu Weigang; Zhou Zhenhua; Liu Luming; Jiang Guoliang

    2011-01-01

    Purpose: To determine the maximum tolerated dose (MTD) of three-dimensional conformal radiation therapy (3DCRT)/intensity-modulated radiation therapy (IMRT) combined with transcatheter arterial chemoembolization for locally advanced hepatocellular carcinoma. Methods and Materials: Patients were assigned to two subgroups based on tumor diameter: Group 1 had tumors <10 cm; Group II had tumors ≥10 cm. Escalation was achieved by increments of 4.0 Gy for each cohort in both groups. Dose-limiting toxicity (DLT) was defined as a grade of ≥3 acute liver or gastrointestinal toxicity or any grade 5 acute toxicity in other organs at risk or radiation-induced liver disease. The dose escalation would be terminated when ≥2 of 8 patients in a cohort experienced DLT. Results: From April 2005 to May 2008, 40 patients were enrolled. In Group I, 11 patients had grade ≤2 acute treatment-related toxicities, and no patient experienced DLT; and in Group II, 10 patients had grade ≤2 acute toxicity, and 1 patient in the group receiving 52 Gy developed radiation-induced liver disease. MTD was 62 Gy for Group I and 52 Gy for Group II. In-field progression-free and local progression-free rates were 100% and 69% at 1 year, and 93% and 44% at 2 years, respectively. Distant metastasis rates were 6% at 1 year and 15% at 2 years. Overall survival rates for 1-year and 2-years were 72% and 62%, respectively. Conclusions: The irradiation dose was safely escalated in hepatocellular carcinoma patients by using 3DCRT/IMRT with an active breathing coordinator. MTD was 62 Gy and 52 Gy for patients with tumor diameters of <10 cm and ≥10 cm, respectively.

  12. Multiobjective evolutionary optimization of the number of beams, their orientations and weights for intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Schreibmann, Eduard; Lahanas, Michael; Xing, Lei; Baltas, Dimos

    2004-01-01

    We propose a hybrid multiobjective (MO) evolutionary optimization algorithm (MOEA) for intensity-modulated radiotherapy inverse planning and apply it to optimize the number of incident beams, their orientations and intensity profiles. The algorithm produces a set of efficient solutions, which represent different clinical trade-offs and contains information such as variety of dose distributions and dose-volume histograms. No importance factors are required and solutions can be obtained in regions not accessible by conventional weighted sum approaches. The application of the algorithm using a test case, a prostate and a head and neck tumour case is shown. The results are compared with MO inverse planning using a gradient-based optimization algorithm

  13. Application of the measurement-based Monte Carlo method in nasopharyngeal cancer patients for intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Yeh, C.Y.; Lee, C.C.; Chao, T.C.; Lin, M.H.; Lai, P.A.; Liu, F.H.; Tung, C.J.

    2014-01-01

    This study aims to utilize a measurement-based Monte Carlo (MBMC) method to evaluate the accuracy of dose distributions calculated using the Eclipse radiotherapy treatment planning system (TPS) based on the anisotropic analytical algorithm. Dose distributions were calculated for the nasopharyngeal carcinoma (NPC) patients treated with the intensity modulated radiotherapy (IMRT). Ten NPC IMRT plans were evaluated by comparing their dose distributions with those obtained from the in-house MBMC programs for the same CT images and beam geometry. To reconstruct the fluence distribution of the IMRT field, an efficiency map was obtained by dividing the energy fluence of the intensity modulated field by that of the open field, both acquired from an aS1000 electronic portal imaging device. The integrated image of the non-gated mode was used to acquire the full dose distribution delivered during the IMRT treatment. This efficiency map redistributed the particle weightings of the open field phase-space file for IMRT applications. Dose differences were observed in the tumor and air cavity boundary. The mean difference between MBMC and TPS in terms of the planning target volume coverage was 0.6% (range: 0.0–2.3%). The mean difference for the conformity index was 0.01 (range: 0.0–0.01). In conclusion, the MBMC method serves as an independent IMRT dose verification tool in a clinical setting. - Highlights: ► The patient-based Monte Carlo method serves as a reference standard to verify IMRT doses. ► 3D Dose distributions for NPC patients have been verified by the Monte Carlo method. ► Doses predicted by the Monte Carlo method matched closely with those by the TPS. ► The Monte Carlo method predicted a higher mean dose to the middle ears than the TPS. ► Critical organ doses should be confirmed to avoid overdose to normal organs

  14. Quality assurance of a helical tomotherapy machine

    International Nuclear Information System (INIS)

    Fenwick, J D; Tome, W A; Jaradat, H A; Hui, S K; James, J A; Balog, J P; DeSouza, C N; Lucas, D B; Olivera, G H; Mackie, T R; Paliwal, B R

    2004-01-01

    Helical tomotherapy has been developed at the University of Wisconsin, and 'Hi-Art II' clinical machines are now commercially manufactured. At the core of each machine lies a ring-gantry-mounted short linear accelerator which generates x-rays that are collimated into a fan beam of intensity-modulated radiation by a binary multileaf, the modulation being variable with gantry angle. Patients are treated lying on a couch which is translated continuously through the bore of the machine as the gantry rotates. Highly conformal dose-distributions can be delivered using this technique, which is the therapy equivalent of spiral computed tomography. The approach requires synchrony of gantry rotation, couch translation, accelerator pulsing and the opening and closing of the leaves of the binary multileaf collimator used to modulate the radiation beam. In the course of clinically implementing helical tomotherapy, we have developed a quality assurance (QA) system for our machine. The system is analogous to that recommended for conventional clinical linear accelerator QA by AAPM Task Group 40 but contains some novel components, reflecting differences between the Hi-Art devices and conventional clinical accelerators. Here the design and dosimetric characteristics of Hi-Art machines are summarized and the QA system is set out along with experimental details of its implementation. Connections between this machine-based QA work, pre-treatment patient-specific delivery QA and fraction-by-fraction dose verification are discussed

  15. A matched-pair comparison of intensity-modulated radiation therapy with cetuximab versus intensity-modulated radiation therapy with platinum-based chemotherapy for locally advanced head neck cancer

    International Nuclear Information System (INIS)

    Huang, J.; Baschnagel, A.M.; Chen, P.; Ye, H.; Krauss, D.; Gustafson, G.; Jaiyesmi, I.; Folbe, M.; Akervall, J.

    2014-01-01

    We retrospectively compared the efficacy of intensity-modulated radiotherapy (IMRT) and cetuximab (IMRT/cetuximab) versus IMRT and platinum-based chemotherapy (IMRT/platinum) for locally advanced head neck squamous cell carcinoma (LAHNSCC). Thirty-one IMRT/cetuximab patients were matched 1:2 with 62 IMRT/platinum patients according to primary site and clinical stage. The primary endpoint was locoregional recurrence (LRR), and secondary endpoints included distant metastasis (DM), cause-specific survival (CSS), and overall survival (OS). Because of inherent selection bias, the IMRT/cetuximab cohort was significantly older and with a higher Charlson Comorbidity Index. IMRT/cetuximab and IMRT/platinum did not have significantly different LRR and DM (33 vs. 23% at 2 years, P=0.22; 17 vs. 11% at 2 years, P=0.40; respectively). IMRT/cetuximab had significantly worse CSS and OS (67 vs. 84%, P=0.04; 58 vs. 83%, P=0.001; respectively). However, for the subset of elderly patients ≥65 years old, there is no difference between the two cohorts for all endpoints (all P=NS). IMRT/platinum should remain the preferred choice of chemoradiotherapy for LAHNSCC, but IMRT/cetuximab may be a reasonable alternative for elderly patients. (author)

  16. Two-Year and Lifetime Cost-Effectiveness of Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy for Head-and-Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kohler, Racquel E. [Department of Health Policy and Management, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Sheets, Nathan C. [Department of Radiation Oncology, University of North Carolina Hospitals, Chapel Hill, North Carolina (United States); Wheeler, Stephanie B. [Department of Health Policy and Management, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Nutting, Chris [Royal Marsden Hospital, London, United Kindom (United Kingdom); Hall, Emma [Clinical Trials and Statistics Unit, Division of Clinical Studies, Institute of Cancer Research, London (United Kingdom); Chera, Bhishamjit S., E-mail: bchera@med.unc.edu [Department of Radiation Oncology, University of North Carolina Hospitals, Chapel Hill, North Carolina (United States)

    2013-11-15

    Purpose: To assess the cost-effectiveness of intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3D-CRT) in the treatment of head-and neck-cancer (HNC). Methods and Materials: We used a Markov model to simulate radiation therapy-induced xerostomia and dysphagia in a hypothetical cohort of 65-year-old HNC patients. Model input parameters were derived from PARSPORT (CRUK/03/005) patient-level trial data and quality-of-life and Medicare cost data from published literature. We calculated average incremental cost-effectiveness ratios (ICERs) from the US health care perspective as cost per quality-adjusted life-year (QALY) gained and compared our ICERs with current cost-effectiveness standards whereby treatment comparators less than $50,000 per QALY gained are considered cost-effective. Results: In the first 2 years after initial treatment, IMRT is not cost-effective compared with 3D-CRT, given an average ICER of $101,100 per QALY gained. However, over 15 years (remaining lifetime on the basis of average life expectancy of a 65-year-old), IMRT is more cost-effective at $34,523 per QALY gained. Conclusion: Although HNC patients receiving IMRT will likely experience reduced xerostomia and dysphagia symptoms, the small quality-of-life benefit associated with IMRT is not cost-effective in the short term but may be cost-effective over a patient's lifetime, assuming benefits persist over time and patients are healthy and likely to live for a sustained period. Additional data quantifying the long-term benefits of IMRT, however, are needed.

  17. The survival analysis on localized prostate cancer treated with neoadjuvant endocrine therapy followed by intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Gao Hong; Li Gaofeng; Wu Qinhong; Li Xuenan; Zhong Qiuzi; Xu Yonggang

    2010-01-01

    Objective: To retrospectively investigate clinical outcomes and prognostic factors in localized prostate cancer treated with neoadjuvant endocrine therapy followed by intensity modulated radiotherapy (IMRT). Methods: Between March 2003 and October 2008, 54 localized prostate cancer treated by IMRT were recruited. All patients had received endocrine therapy before IMRT. The endocrine therapy included surgical castration or medical castration in combination with antiandrogens. The target of IMRT was the prostate and seminal vesicles with or without pelvis. The biochemical failure was defined according to the phoenix definition. By using the risk grouping standard proposed by D'Amico, patients were divided into three groups: low-risk group (n = 5), intermediate-risk group (n = 12), and high-risk group (n = 37). Kaplan-Meier method was used to calculate the overall survival rate. Prognostic factors were analyzed by univariate and multiple Cox regression analysis. Results: The follow-up rate was 98%. The number of patients under follow-up was 39 at 3 years and 25 at 5 years. Potential prognostic factors, including risk groups, mode of endocrine therapy, time of endocrine therapy, phoenix grouping before IMRT, the prostate specific antigen doubling time (PSADT) before radiotherapy, PSA value before IMRT, interval of endocrine therapy and IMRT, irradiation region, and irradiation dose were analyzed by survival analysis. In univariate analysis, time of endocrine therapy (75 % vs 95 %, χ 2 = 6. 45, P = 0. 011), phoenix grouping before IMRT (87% vs 96%, χ 2 = 4. 36, P = 0. 037), interval of endocrine therapy and IMRT (80% vs 95%, χ 2 = 11.60, P= 0. 001), irradiation dose (75% vs 91%, χ 2 =5.92, P= 0. 015) were statistically significant prognostic factors for 3 - year overall survival , and risk groups (85 vs 53 vs 29, χ 2 = 6. 40, P =0. 041) and PSADT before IMRT (62 vs 120, U =24. 50, P =0. 003) were significant factors for the median survival time. In the multiple Cox

  18. Comparison of volumetric modulated arc therapy and intensity modulated radiation therapy for whole brain hippocampal sparing treatment plans based on radiobiological modeling

    Directory of Open Access Journals (Sweden)

    Ethan Kendall

    2018-01-01

    Full Text Available Introduction: In this article, we report the results of our investigation on comparison of radiobiological aspects of treatment plans with linear accelerator-based intensity-modulated radiation therapy and volumetric-modulated arc therapy for patients having hippocampal avoidance whole-brain radiation therapy. Materials and Methods: In this retrospective study using the dose-volume histogram, we calculated and compared biophysical indices of equivalent uniform dose, tumor control probability, and normal tissue complication probability (NTCP for 15 whole-brain radiotherapy patients. Results and Discussions: Dose-response models for tumors and critical structures were separated into two groups: mechanistic and empirical. Mechanistic models formulate mathematically with describable relationships while empirical models fit data through empirical observations to appropriately determine parameters giving results agreeable to those given by mechanistic models. Conclusions: Techniques applied in this manuscript could be applied to any other organs or types of cancer to evaluate treatment plans based on radiobiological modeling.

  19. Comparison of quality of life in patients with nasopharyngeal carcinoma receiving conventional external beam radiation therapy versus intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Zheng Lu; Yan Senxiang; Yan Danfang

    2011-01-01

    Objective: To compare the acute and late adverse events and quality of life (QOL) in patients with nasopharyngeal carcinomas receiving conventional external beam radiation therapy (RT) versus intensity modulated radiation therapy (IMRT). Methods: Ninety-one patients with newly diagnosed nasopharyngeal carcinoma treated in our institution between August 2008 and September 2010 were systemically reviewed, including 35 cases administered with conventional RT (RT group) and 56 cases with IMRT (IMRT group). Conjoint faciocervical fields plus tangential lower neck-supraclavicular field initially, and then shrinking preauricular portals plus electron beams to the neck were adopted in RT groups, with a total dose of 70 Gy/35 fractions.Nine coplanar fields were conducted in IMRT group with a total dose of 69.96 Gy/33 fractions. Acute and late adverse reactions were observed and compared between RT and IMRT groups, including acute reactions as xerostomia, odynophagia, dermatitis/mucositis and late events as dysphagia, trismus, hypothyroidism, optic/acoustic impairments, skin injury, hypodermal fibrosis, spinal myelitis and brain injury. Results: Compared with RT group, IMRT group showed less acute reactions in xerostomia, odynophagia, dysphagia and dermatitis and mucositis (χ 2 =85.73, 56.03, 26.58, 69.28, 55.99, P<0.05), and less late reactions in xerostomia, dysphagia, trismus, taste loss and skin injury (χ 2 =37.95, 7.48, 9.49, 9.49, 11.87, P<0.05), whereas the degree of acoustic/optic impairments and brain injury showed no difference in both groups. Conclusions: As compared to conventional RT, IMRT could decrease acute and some late side events, and improve the quality of life in patients with nasopharyngeal carcinoma. (authors)

  20. A novel schedule of accelerated partial breast radiation using intensity-modulated radiation therapy in elderly patients: survival and toxicity analysis of a prospective clinical trial

    Energy Technology Data Exchange (ETDEWEB)

    Sayan, Mutlay; Nelson, Carl; Gagne, Havaleh; Rubin, Deborah; Heimann, Ruth [Dept. of Radiation Oncology, University of Vermont Medical Center, Burlington (United States); Wilson, Karen [University of Vermont Cancer Center, Burlington (United States)

    2017-03-15

    Several accelerated partial breast radiation (APBR) techniques have been investigated in patients with early-stage breast cancer (BC); however, the optimal treatment delivery techniques remain unclear. We evaluated the feasibility and toxicity of APBR delivered using intensity-modulated radiation therapy (IMRT) in elderly patients with stage I BC, using a novel fractionation schedule. Forty-two patients aged ≥65 years, with stage I BC who underwent breast conserving surgery were enrolled in a phase I/II study evaluating APBR using IMRT. Forty eligible patients received 40 Gy in 4 Gy daily fractions. Patients were assessed for treatment related toxicities, and cosmesis, before APBR, during, and after completion of the treatment. The median age was 73 years, median tumor size 0.8 cm and the median follow-up was 54 months. The 5-year locoregional control was 97.5% and overall survival 90%. Erythema and skin pigmentation was the most common acute adverse event, reported by 27 patients (69%). Twenty-six patients (65%) reported mild pain, rated 1-4/10. This improved at last follow-up to only 2 (15%). Overall the patient and physician reported worst late toxicities were lower than the baseline and at last follow-up, patients and physicians rated cosmesis as excellent/good in 93% and 86 %, respectively. In this prospective trial, we observed an excellent rate of tumor control with daily APBR. The acceptable toxicity profile and cosmetic results of this study support the use of IMRT planned APBR with daily schedule in elderly patients with early stage BC.

  1. Forward-planned intensity modulated radiation therapy using a cobalt source: A dosimetric study in breast cancer

    Directory of Open Access Journals (Sweden)

    Savino Cilla

    2013-01-01

    Full Text Available This analysis evaluates the feasibility and dosimetric results of a simplified intensity-modulated radiotherapy (IMRT treatment using a cobalt-therapy unit for post-operative breast cancer. Fourteen patients were included. Three plans per patient were produced by a cobalt-60 source: A standard plan with two wedged tangential beams, a standard tangential plan optimized without the use of wedges and a plan based on the forward-planned "field-in-field" IMRT technique (Co-FinF where the dose on each of the two tangential beams was split into two different segments and the two segments weight was determined with an iterative process. For comparison purposes, a 6-MV photon standard wedged tangential treatment plan was generated. D mean , D 98% , D 2% , V 95% , V 107%, homogeneity, and conformity indices were chosen as parameters for comparison. Co-FinF technique improved the planning target volume dose homogeneity compared to other cobalt-based techniques and reduced maximum doses (D 2% and high-dose volume (V 110% . Moreover, it showed a better lung and heart dose sparing with respect to the standard approach. The higher dose homogeneity may encourage the adoption of accelerated-hypofractionated treatments also with the cobalt sources. This approach can promote the spread of breast conservative treatment in developing countries.

  2. Impact of Expression of CD44, a Cancer Stem Cell Marker, on the Treatment Outcomes of Intensity Modulated Radiation Therapy in Patients With Oropharyngeal Squamous Cell Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Motegi, Atsushi, E-mail: amotegi@east.ncc.go.jp [Division of Radiation Oncology, National Cancer Center Hospital East, Kashiwa, Chiba (Japan); Fujii, Satoshi [Pathology Division, Research Center for Innovative Oncology, National Cancer Center Hospital East, Kashiwa, Chiba (Japan); Zenda, Sadamoto; Arahira, Satoko [Division of Radiation Oncology, National Cancer Center Hospital East, Kashiwa, Chiba (Japan); Tahara, Makoto [Division of Head and Neck Oncology, National Cancer Center Hospital East, Kashiwa, Chiba (Japan); Hayashi, Ryuichi [Division of Head and Neck Surgery, National Cancer Center Hospital East, Kashiwa, Chiba (Japan); Akimoto, Tetsuo [Division of Radiation Oncology, National Cancer Center Hospital East, Kashiwa, Chiba (Japan)

    2016-03-01

    Purpose: To investigate the significance of CD44 protein expression on the treatment outcomes of radiation therapy in patients with oropharyngeal squamous cell carcinoma (OPSCC) with or without p16 protein expression in the tumor tissue. Methods and Materials: We reviewed the medical records of 58 OPSCC patients who had undergone radiation therapy and examined the tumor tissue expressions of CD44 and p16 protein by immunohistochemical staining. The correlations between the expressions of these proteins and the patients' treatment outcomes were analyzed. Results: The data of 58 consecutive OPSCC patients who had undergone definitive intensity modulated radiation therapy were analyzed. The male/female ratio was 55:3, and the median age was 64 years. The clinical stage of the disease was stage II in 7 patients, stage III in 5 patients, stage IVA in 35 patients, and stage IVB in 11 patients. Of the patients, 79% received additional induction and/or concurrent chemotherapy. The median follow-up duration was 34 months. The 3-year overall survival, progression-free survival (PFS) and locoregional control (LRC) rates of all the patients, regardless of the results of immunohistochemistry, were 73%, 64% and 76%, respectively. The PFS and LRC rates in the CD44{sup −} patients (86% and 93%, respectively) were significantly higher than those in the CD44{sup +} patients (57% and 70%, respectively). The PFS and LRC rates in the p16{sup +} patients (83% and 90%, respectively) were significantly higher than those in the p16{sup −} patients (45% and 61%, respectively). Patients who were CD44{sup −}/p16{sup +} showed the best LRC rates, and those who were CD44{sup +}/p16{sup −} showed the worst PFS and LRC rates among all the groups. Conclusions: Profiling of CD44 and p16 protein expressions by immunohistochemical staining is useful for predicting the treatment outcomes in patients with OPSCC undergoing definitive intensity modulated radiation therapy.

  3. Late Side Effects After Image Guided Intensity Modulated Radiation Therapy Compared to 3D-Conformal Radiation Therapy for Prostate Cancer: Results From 2 Prospective Cohorts

    Energy Technology Data Exchange (ETDEWEB)

    Wortel, Ruud C.; Incrocci, Luca [Department of Radiation Oncology, Erasmus Medical Center Cancer Institute, Rotterdam (Netherlands); Pos, Floris J.; Heide, Uulke A. van der; Lebesque, Joos V. [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Aluwini, Shafak [Department of Radiation Oncology, Erasmus Medical Center Cancer Institute, Rotterdam (Netherlands); Witte, Marnix G. [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Heemsbergen, Wilma D., E-mail: w.heemsbergen@nki.nl [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands)

    2016-06-01

    Purpose: Technical developments in the field of external beam radiation therapy (RT) enabled the clinical introduction of image guided intensity modulated radiation therapy (IG-IMRT), which improved target conformity and allowed reduction of safety margins. Whether this had an impact on late toxicity levels compared to previously applied three-dimensional conformal radiation therapy (3D-CRT) is currently unknown. We analyzed late side effects after treatment with IG-IMRT or 3D-CRT, evaluating 2 prospective cohorts of men treated for localized prostate cancer to investigate the hypothesized reductions in toxicity. Methods and Materials: Patients treated with 3D-CRT (n=189) or IG-IMRT (n=242) to 78 Gy in 39 fractions were recruited from 2 Dutch randomized trials with identical toxicity scoring protocols. Late toxicity (>90 days after treatment) was derived from self-assessment questionnaires and case report forms, according to Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer (RTOG-EORTC) scoring criteria. Grade ≥2 endpoints included gastrointestinal (GI) rectal bleeding, increased stool frequency, discomfort, rectal incontinence, proctitis, and genitourinary (GU) obstruction, increased urinary frequency, nocturia, urinary incontinence, and dysuria. The Cox proportional hazards regression model was used to compare grade ≥2 toxicities between both techniques, adjusting for other modifying factors. Results: The 5-year cumulative incidence of grade ≥2 GI toxicity was 24.9% for IG-IMRT and 37.6% following 3D-CRT (adjusted hazard ratio [HR]: 0.59, P=.005), with significant reductions in proctitis (HR: 0.37, P=.047) and increased stool frequency (HR: 0.23, P<.001). GU grade ≥2 toxicity levels at 5 years were comparable with 46.2% and 36.4% following IG-IMRT and 3D-CRT, respectively (adjusted HR: 1.19, P=.33). Other strong predictors (P<.01) of grade ≥2 late toxicity were baseline complaints, acute toxicity, and age

  4. Reduced Toxicity With Intensity Modulated Radiation Therapy (IMRT) for Desmoplastic Small Round Cell Tumor (DSRCT): An Update on the Whole Abdominopelvic Radiation Therapy (WAP-RT) Experience

    International Nuclear Information System (INIS)

    Desai, Neil B.; Stein, Nicholas F.; LaQuaglia, Michael P.; Alektiar, Kaled M.; Kushner, Brian H.; Modak, Shakeel; Magnan, Heather M.; Goodman, Karyn; Wolden, Suzanne L.

    2013-01-01

    Purpose: Desmoplastic small round cell tumor (DSRCT) is a rare malignancy typically involving the peritoneum in young men. Whole abdominopelvic radiation therapy (WAP-RT) using conventional 2-dimensional (2D) radiation therapy (RT) is used to address local recurrence but has been limited by toxicity. Our objectives were to assess the benefit of intensity modulated radiation therapy (IMRT) on toxicity and to update the largest series on radiation for DSRCT. Methods and Materials: The records of 31 patients with DSRCT treated with WAP-RT (22 with 2D-RT and 9 with IMRT) between 1992 and 2011 were retrospectively reviewed. All received multi-agent chemotherapy and maximal surgical debulking followed by 30 Gy of WAP-RT. A further focal boost of 12 to 24 Gy was used in 12 cases. Boost RT and autologous stem cell transplantation were nearly exclusive to patients treated with 2D-RT. Toxicities were assessed with the Common Terminology Criteria for Adverse Events. Dosimetric analysis compared IMRT and simulated 2D-RT dose distributions. Results: Of 31 patients, 30 completed WAP-RT, with a median follow-up after RT of 19 months. Acute toxicity was reduced with IMRT versus 2D-RT: P=.04 for gastrointestinal toxicity of grade 2 or higher (33% vs 77%); P=.02 for grade 4 hematologic toxicity (33% vs 86%); P=.01 for rates of granulocyte colony-stimulating factor; and P=.04 for rates of platelet transfusion. Post treatment red blood cell and platelet transfusion rates were also reduced (P=.01). IMRT improved target homogeneity ([D05-D95]/D05 of 21% vs 46%) and resulted in a 21% mean bone dose reduction. Small bowel obstruction was the most common late toxicity (23% overall). Updated 3-year overall survival and progression-free survival rates were 50% and 24%, respectively. Overall survival was associated with distant metastasis at diagnosis on multivariate analysis. Most failures remained intraperitoneal (88%). Conclusions: IMRT for consolidative WAP-RT in DSRCT improves

  5. Nasopharyngeal Carcinoma Treated with Precision-Oriented Radiation Therapy Techniques Including Intensity-Modulated Radiotherapy: Preliminary Results

    Directory of Open Access Journals (Sweden)

    Wen-Shan Liu

    2004-02-01

    Full Text Available This paper reports preliminary results with intensity-modulated radiotherapy (IMRT in nasopharyngeal carcinoma (NPC. Between August 2000 and May 2001, we treated 19 patients with NPC using IMRT. Twelve patients had stage I-II disease and seven had stage III-IV disease. Six patients received 9.0-19.8 Gy three-dimensional conformal radiotherapy (3D-CRT before IMRT and 18 patients received a brachytherapy boost after IMRT. The mean follow-up time was 13.0 months. All patients with stage II-IV disease except one received two cycles of chemoradiotherapy with cisplatin and 5-fluorouracil (5-FU during radiotherapy, followed by two to four cycles of chemotherapy after radiotherapy. Tumor response was assessed using clinical examination and computerized tomography or magnetic resonance imaging. The mean doses administered to the gross tumor volume and clinical tumor volume were 70.9 Gy and 63.2 Gy, respectively. The mean doses administered to the right and left parotid glands were 38.1 Gy and 38.6 Gy, respectively. All 19 patients had a complete response of primary and lymph node disease. Grade III mucositis developed during chemoradiotherapy in 15 patients (79%. In addition, clinical grade I xerostomia was recorded in nine patients, grade II in nine, and grade III in one. This study demonstrated that 3D-CRT, IMRT, intracavitary brachytherapy, and chemotherapy are effective and safe methods to treat NPC. Although IMRT treatment spared parotid gland function, its efficacy may be significantly influenced by disease stage and location of the neck lymph nodes. More cases and a longer follow-up to assess survival and complications are planned.

  6. Factors affecting the implementation of complex and evolving technologies: multiple case study of intensity-modulated radiation therapy (IMRT in Ontario, Canada

    Directory of Open Access Journals (Sweden)

    Bak Kate

    2011-07-01

    Full Text Available Abstract Background Research regarding the decision to adopt and implement technological innovations in radiation oncology is lacking. This is particularly problematic since these technologies are often complex and rapidly evolving, requiring ongoing revisiting of decisions regarding which technologies are the most appropriate to support. Variations in adoption and implementation decisions for new radiation technologies across cancer centres can impact patients' access to appropriate and innovative forms of radiation therapy. This study examines the key steps in the process of adopting and implementing intensity modulated radiation therapy (IMRT in publicly funded cancer centres and identifies facilitating or impeding factors. Methods A multiple case study design, utilizing document analysis and key informant interviews was employed. Four cancer centres in Ontario, Canada were selected and interviews were conducted with radiation oncologists, medical physicists, radiation therapists, and senior administrative leaders. Results Eighteen key informants were interviewed. Overall, three centres made fair to excellent progress in the implementation of IMRT, while one centre achieved only limited implementation as of 2009. Key factors that influenced the extent of IMRT implementation were categorized as: 1 leadership, 2 training, expertise and standardization, 3 collaboration, 4 resources, and 5 resistance to change. Conclusion A framework for the adoption and implementation of complex and evolving technologies is presented. It identifies the key factors that should be addressed by decision-makers at specific stages of the adoption/implementation process.

  7. Factors affecting the implementation of complex and evolving technologies: multiple case study of intensity-modulated radiation therapy (IMRT) in Ontario, Canada.

    Science.gov (United States)

    Bak, Kate; Dobrow, Mark J; Hodgson, David; Whitton, Anthony

    2011-07-31

    Research regarding the decision to adopt and implement technological innovations in radiation oncology is lacking. This is particularly problematic since these technologies are often complex and rapidly evolving, requiring ongoing revisiting of decisions regarding which technologies are the most appropriate to support. Variations in adoption and implementation decisions for new radiation technologies across cancer centres can impact patients' access to appropriate and innovative forms of radiation therapy. This study examines the key steps in the process of adopting and implementing intensity modulated radiation therapy (IMRT) in publicly funded cancer centres and identifies facilitating or impeding factors. A multiple case study design, utilizing document analysis and key informant interviews was employed. Four cancer centres in Ontario, Canada were selected and interviews were conducted with radiation oncologists, medical physicists, radiation therapists, and senior administrative leaders. Eighteen key informants were interviewed. Overall, three centres made fair to excellent progress in the implementation of IMRT, while one centre achieved only limited implementation as of 2009. Key factors that influenced the extent of IMRT implementation were categorized as: 1) leadership, 2) training, expertise and standardization, 3) collaboration, 4) resources, and 5) resistance to change. A framework for the adoption and implementation of complex and evolving technologies is presented. It identifies the key factors that should be addressed by decision-makers at specific stages of the adoption/implementation process.

  8. Correlating planned radiation dose to the cochlea with primary site and tumor stage in patients with head and neck cancer treated with intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jeanette; Qureshi, Muhammad M.; Kovalchuk, Nataliya; Truong, Minh Tam, E-mail: mitruong@bu.edu

    2014-04-01

    The aim of the study was to determine tumor characteristics that predict higher planned radiation (RT) dose to the cochlea in patients with head and neck cancer (HNC) treated with intensity-modulated radiotherapy (IMRT). From 2004 to 2012, 99 patients with HNC underwent definitive IMRT to a median dose of 69.96 Gy in 33 fractions, with the right and left cochlea-vestibular apparatus contoured for IMRT optimization as avoidance structures. If disease involvement was adjacent to the cochlea, preference was given to tumor coverage by prescription dose. Descriptive statistics were calculated for dose-volume histogram planning data, and mean planning dose to the cochlea (from left or right cochlea, receiving the greater amount of RT dose) was correlated to primary site and tumor stage. Mean (standard deviation) cochlear volume was 1.0 (0.60) cm{sup 3} with maximum and mean planned doses of 31.9 (17.5) Gy and 22.1 (13.7) Gy, respectively. Mean planned dose (Gy) to cochlea by tumor site was as follows: oral cavity (18.6, 14.4), oropharynx (21.7, 9.1), nasopharynx (36.3, 10.4), hypopharynx (14.9, 7.1), larynx (2.1, 0.62), others including the parotid gland, temporal bone, and paranasal sinus (33.6, 24.0), and unknown primary (25.6, 6.7). Average mean planned dose (Gy) to the cochlea in T0-T2 and T3-T4 disease was 22.0 and 29.2 Gy, respectively (p = 0.019). By site, a significant difference was noted for nasopharynx and others (31.6 and 50.7, p = 0.012) but not for oropharynx, oral cavity, and hypopharynx. Advanced T category predicted for higher mean cochlear dose, particularly for nasopharyngeal, parotid gland, temporal bone, and paranasal sinus HNC sites.

  9. Integral dose delivered to normal brain with conventional intensity-modulated radiotherapy (IMRT) and helical tomotherapy IMRT during partial brain radiotherapy for high-grade gliomas with and without selective sparing of the hippocampus, limbic circuit and neural stem cell compartment

    International Nuclear Information System (INIS)

    Marsh, James C.; Ziel, Ellis G; Diaz, Aidnag Z; Turian, Julius V; Wendt, Julie A.; Gobole, Rohit

    2013-01-01

    We compared integral dose with uninvolved brain (ID brain ) during partial brain radiotherapy (PBRT) for high-grade glioma patients using helical tomotherapy (HT) and seven field traditional inverse-planned intensity-modulated radiotherapy (IMRT) with and without selective sparing (SPA) of contralateral hippocampus, neural stem cell compartment (NSC) and limbic circuit. We prepared four PBRT treatment plans for four patients with high-grade gliomas (60Gy in 30 fractions delivered to planning treatment volume (PTV60Gy)). For all plans, a structure denoted 'uninvolved brain' was created, which included all brain tissue not part of PTV or standard (STD) organs at risk (OAR). No dosimetric constraints were included for uninvolved brain. Selective SPA plans were prepared with IMRT and HT; contralateral hippocampus, NSC and limbic circuit were contoured; and dosimetric constraints were entered for these structures without compromising dose to PTV or STD OAR. We compared V100 and D95 for PTV46Gy and PTV60Gy, and ID brain for all plans. There were no significant differences in V100 and D95 for PTV46Gy and PTV60Gy. ID brain was lower in traditional IMRT versus HT plans for STD and SPA plans (mean ID brain 23.64Gy vs. 28Gy and 18.7Gy vs. 24.5Gy, respectively) and in SPA versus STD plans both with IMRT and HT (18.7Gy vs. 23.64Gy and 24.5Gy vs. 28Gy, respectively). n the setting of PBRT for high-grade gliomas, IMRT reduces ID brain compared with HT with or without selective SPA of contralateral hippocampus, limbic circuit and NSC, and the use of selective SPA reduces ID brain compared with STD PBRT delivered with either traditional IMRT or HT.

  10. SU-F-P-26: Study of Radiation Dose Evaluation for Organs at Risk Using MRI in Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Gong, G; Guo, Y; Yin, Y [Shandong Cancer Hospital and Institute, Jinan, Shandong (China)

    2016-06-15

    Purpose: To study the contour and dosimetric feature of organs at risk (OARs) applying magnetic resonance imaging (MRI) images in intensity modulated radiation therapy (IMRT) of nasopharyngeal carcinoma (NPC) compared to computed tomography (CT) images. Methods: 35 NPC patients was selected into this trail. CT simulation with non-contrast and contrast enhanced scan, MRI simulation with non-contrast and contrast enhanced T1, T2 and diffusion weighted imaging were achieved sequentially. And the OARs were contoured on the CT and MRI images after rigid registration respectively. 9 beams IMRT plan with equal division angle were designed for every patients, and the prescription dose for tumor target was set as 72Gy (2.4Gy/ fration). The boundary display, volume and dose-volume indices of each organ were compared between on MRI and CT images. Results: Compared to CT, MRI showed clearer boundary of brainstem, spinal cord, the deep lobe of Parotid gland and the optical nerve in canal. MRI images increase the volume of lens, optical nerve, while reducing the volume of eye slightly, and the maximum dose of lens, the mean dose of eyes and optical raised in different percentage, while there was no statistical differences were found. The left and right parotid volume on MRI increased by 7.07%, 8.13%, and the mean dose raised by 14.95% (4.01Gy), 18.76% (4.95Gy) with statistical significant difference (p<0.05). The brainstem volume reduced by 9.33% (p<0.05), and the dose of 0.1cm3 volume (D0.1cm3) reduced by mean 8.46% (4.32Gy), and D0.1cm3 of spinal cord increased by 1.5Gy on MRI. Conclusion: It is credible to evaluate the radiation dose of lens, eye and the spinal cord, while it should be necessary to evaluate the dose of brainstem, parotid and the optical nerve applying MRI images sometime, it will be more meaningful for these organs with high risk of radiation injury.

  11. Predicting the severity and prognosis of trismus after intensity-modulated radiation therapy for oral cancer patients by magnetic resonance imaging.

    Science.gov (United States)

    Hsieh, Li-Chun; Chen, John W; Wang, Li-Ying; Tsang, Yuk-Ming; Shueng, Pei-Wei; Liao, Li-Jen; Lo, Wu-Chia; Lin, Yu-Chin; Tseng, Chien-Fu; Kuo, Ying-Shiung; Jhuang, Jie-Yang; Tien, Hui-Ju; Juan, Hsueh-Fen; Hsieh, Chen-Hsi

    2014-01-01

    To develop magnetic resonance imaging (MRI) indicators to predict trismus outcome for post-operative oral cavity cancer patients who received adjuvant intensity-modulated radiation therapy (IMRT), 22 patients with oral cancer treated with IMRT were studied over a two-year period. Signal abnormality scores (SA scores) were computed from Likert-type ratings of the abnormalities of nine masticator structures and compared with the Mann-Whitney U-test and Kruskal-Wallis one-way ANOVA test between groups. Seventeen patients (77.3%) experienced different degrees of trismus during the two-year follow-up period. The SA score correlated with the trismus grade (r = 0.52, ptrismus had higher mean doses of radiation to multiple structures, including the masticator and lateral pterygoid muscles, and the parotid gland (ptrismus patients. The SA score, as determined using MRI, can reflect the radiation injury and correlate to trismus severity. Together with the radiation dose, it could serve as a useful biomarker to predict the outcome and guide the management of trismus following radiation therapy.

  12. Results of the radiation dose of head, body and tail of hippocampus in nasopharyngeal carcinoma patients treated with intensity modulated radiotherapy.

    Science.gov (United States)

    Zong-Wen, Sun; Lei, Shi; Qinglin, Li; Yue, Kong; Feng-Lei, Du; Tie-Ming, Xie; Yong-Hong, Hua; Qiao-Ying, Hu; Xiao-Zhong, Chen; Yuan-Yuan, Chen; Ming, Chen

    2018-04-04

    This study is to analyze the radiation dose of head, body and tail of hippocampus (HC) of nasopharyngeal carcinoma (NPC) patients treated with intensity modulated radiotherapy (IMRT). Evaluate cognitive function of patients with Wechsler adult intelligence scale-Chinese revised (WAIS-CR). HC were segmented into HC head (HH), HC body (HB) and HC tail (HT) and the indexes were then analyzed. WAIS-CR was tested before and 3months after radiotherapy. The mean radiation dose of left and right HC was (1147 ± 976)cGy, (1011 ± 602)cGy respectively. The radiation dose and the volume exposed in different dose of HH, HB and HT decreased in turn. For 5 patients, before and after radiotherapy, the regular-order score was 8.60 ± 1.34, 8.0 ± 1.00 (P = 0.43), while the reverse-order score was 5.80 ± 0.84, 5.20 ± 0.84 (P = 0.07). The radiation dose of HH, HB and HT was different, and the radiation dose of HH was the highest, which should be emphasized especially.

  13. Predicting the severity and prognosis of trismus after intensity-modulated radiation therapy for oral cancer patients by magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Li-Chun Hsieh

    Full Text Available To develop magnetic resonance imaging (MRI indicators to predict trismus outcome for post-operative oral cavity cancer patients who received adjuvant intensity-modulated radiation therapy (IMRT, 22 patients with oral cancer treated with IMRT were studied over a two-year period. Signal abnormality scores (SA scores were computed from Likert-type ratings of the abnormalities of nine masticator structures and compared with the Mann-Whitney U-test and Kruskal-Wallis one-way ANOVA test between groups. Seventeen patients (77.3% experienced different degrees of trismus during the two-year follow-up period. The SA score correlated with the trismus grade (r = 0.52, p<0.005. Patients having progressive trismus had higher mean doses of radiation to multiple structures, including the masticator and lateral pterygoid muscles, and the parotid gland (p<0.05. In addition, this group also had higher SA-masticator muscle dose product at 6 months and SA scores at 12 months (p<0.05. At the optimum cut-off points of 0.38 for the propensity score, the sensitivity was 100% and the specificity was 93% for predicting the prognosis of the trismus patients. The SA score, as determined using MRI, can reflect the radiation injury and correlate to trismus severity. Together with the radiation dose, it could serve as a useful biomarker to predict the outcome and guide the management of trismus following radiation therapy.

  14. Whole abdomen radiation therapy in ovarian cancers: a comparison between fixed beam and volumetric arc based intensity modulation

    International Nuclear Information System (INIS)

    Mahantshetty, Umesh; Shrivastava, Shyamkishore; Cozzi, Luca; Jamema, Swamidas; Engineer, Reena; Deshpande, Deepak; Sarin, Rajiv; Fogliata, Antonella; Nicolini, Giorgia; Clivio, Alessandro; Vanetti, Eugenio

    2010-01-01

    A study was performed to assess dosimetric characteristics of volumetric modulated arcs (RapidArc, RA) and fixed field intensity modulated therapy (IMRT) for Whole Abdomen Radiotherapy (WAR) after ovarian cancer. Plans for IMRT and RA were optimised for 5 patients prescribing 25 Gy to the whole abdomen (PTV-WAR) and 45 Gy to the pelvis and pelvic nodes (PTV-Pelvis) with Simultaneous Integrated Boost (SIB) technique. Plans were investigated for 6 MV (RA6, IMRT6) and 15 MV (RA15, IMRT15) photons. Objectives were: for both PTVs V 90% > 95%, for PTV-Pelvis: D max < 105%; for organs at risk, maximal sparing was required. The MU and delivery time measured treatment efficiency. Pre-treatment Quality assurance was scored with Gamma Agreement Index (GAI) with 3% and 3 mm thresholds. IMRT and RapidArc resulted comparable for target coverage. For PTV-WAR, V 90% was 99.8 ± 0.2% and 93.4 ± 7.3% for IMRT6 and IMRT15, and 98.4 ± 1.7 and 98.6 ± 0.9% for RA6 and RA15. Target coverage resulted improved for PTV-Pelvis. Dose homogeneity resulted slightly improved by RA (Uniformity was defined as U 5-95% = D 5% -D 95% /D mean ). U 5 - 95% for PTV-WAR was 0.34 ± 0.05 and 0.32 ± 0.06 (IMRT6 and IMRT15), 0.30 ± 0.03 and 0.26 ± 0.04 (RA6 and RA15); for PTV-Pelvis, it resulted equal to 0.1 for all techniques. For organs at risk, small differences were observed between the techniques. MU resulted 3130 ± 221 (IMRT6), 2841 ± 318 (IMRT15), 538 ± 29 (RA6), 635 ± 139 (RA15); the average measured treatment time was 18.0 ± 0.8 and 17.4 ± 2.2 minutes (IMRT6 and IMRT15) and 4.8 ± 0.2 (RA6 and RA15). GAI IMRT6 = 97.3 ± 2.6%, GAI IMRT15 = 94.4 ± 2.1%, GAI RA6 = 98.7 ± 1.0% and GAI RA15 = 95.7 ± 3.7%. RapidArc showed to be a solution to WAR treatments offering good dosimetric features with significant logistic improvements compared to IMRT

  15. Whole abdomen radiation therapy in ovarian cancers: a comparison between fixed beam and volumetric arc based intensity modulation

    Directory of Open Access Journals (Sweden)

    Clivio Alessandro

    2010-11-01

    Full Text Available Abstract Purpose A study was performed to assess dosimetric characteristics of volumetric modulated arcs (RapidArc, RA and fixed field intensity modulated therapy (IMRT for Whole Abdomen Radiotherapy (WAR after ovarian cancer. Methods and Materials Plans for IMRT and RA were optimised for 5 patients prescribing 25 Gy to the whole abdomen (PTV_WAR and 45 Gy to the pelvis and pelvic nodes (PTV_Pelvis with Simultaneous Integrated Boost (SIB technique. Plans were investigated for 6 MV (RA6, IMRT6 and 15 MV (RA15, IMRT15 photons. Objectives were: for both PTVs V90% > 95%, for PTV_Pelvis: Dmax Results IMRT and RapidArc resulted comparable for target coverage. For PTV_WAR, V90% was 99.8 ± 0.2% and 93.4 ± 7.3% for IMRT6 and IMRT15, and 98.4 ± 1.7 and 98.6 ± 0.9% for RA6 and RA15. Target coverage resulted improved for PTV_Pelvis. Dose homogeneity resulted slightly improved by RA (Uniformity was defined as U5-95% = D5%-D95%/Dmean. U5-95% for PTV_WAR was 0.34 ± 0.05 and 0.32 ± 0.06 (IMRT6 and IMRT15, 0.30 ± 0.03 and 0.26 ± 0.04 (RA6 and RA15; for PTV_Pelvis, it resulted equal to 0.1 for all techniques. For organs at risk, small differences were observed between the techniques. MU resulted 3130 ± 221 (IMRT6, 2841 ± 318 (IMRT15, 538 ± 29 (RA6, 635 ± 139 (RA15; the average measured treatment time was 18.0 ± 0.8 and 17.4 ± 2.2 minutes (IMRT6 and IMRT15 and 4.8 ± 0.2 (RA6 and RA15. GAIIMRT6 = 97.3 ± 2.6%, GAIIMRT15 = 94.4 ± 2.1%, GAIRA6 = 98.7 ± 1.0% and GAIRA15 = 95.7 ± 3.7%. Conclusion RapidArc showed to be a solution to WAR treatments offering good dosimetric features with significant logistic improvements compared to IMRT.

  16. Radiobiological evaluation of simultaneously dose-escalated versus non-escalated intensity-modulated radiation therapy for patients with upper thoracic esophageal cancer

    Directory of Open Access Journals (Sweden)

    Huang BT

    2017-04-01

    Full Text Available Bao-Tian Huang,1,* Li-Li Wu,1,* Long-Jia Guo,1,* Liang-Yu Xu,1,* Rui-Hong Huang,1 Pei-Xian Lin,2 Jian-Zhou Chen,1,3 De-Rui Li,1 Chuang-Zhen Chen1 1Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, 2Department of Nosocomial Infection Management, The Second Affiliated Hospital of Shantou University Medical College, Shantou, People’s Republic of China; 3CRUK/MRC Oxford Institute for Radiation Oncology, University of Oxford, Oxford, United Kingdom *These authors contributed equally to this work Objective: To compare the radiobiological response between simultaneously dose-escalated and non-escalated intensity-modulated radiation therapy (DE-IMRT and NE-IMRT for patients with upper thoracic esophageal cancer (UTEC using radiobiological evaluation. Methods: Computed tomography simulation data sets for 25 patients pathologically diagnosed with primary UTEC were used in this study. DE-IMRT plan with an escalated dose of 64.8 Gy/28 fractions to the gross tumor volume (GTV and involved lymph nodes from 25 patients pathologically diagnosed with primary UTEC, was compared to an NE-IMRT plan of 50.4 Gy/28 fractions. Dose-volume metrics, tumor control probability (TCP, and normal tissue complication probability for the lung and spinal cord were compared. In addition, the risk of acute esophageal toxicity (AET and late esophageal toxicity (LET were also analyzed. Results: Compared with NE-IMRT plan, we found the DE-IMRT plan resulted in a 14.6 Gy dose escalation to the GTV. The tumor control was predicted to increase by 31.8%, 39.1%, and 40.9% for three independent TCP models. The predicted incidence of radiation pneumonitis was similar (3.9% versus 3.6%, and the estimated risk of radiation-induced spinal cord injury was extremely low (<0.13% in both groups. Regarding the esophageal toxicities, the estimated grade ≥2 and grade ≥3 AET predicted by the Kwint model were increased by 2.5% and 3.8%. Grade ≥2

  17. Significance of primary tumor volume and T-stage on prognosis in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy.

    Science.gov (United States)

    Chen, Chuanben; Fei, Zhaodong; Pan, Jianji; Bai, Penggang; Chen, Lisha

    2011-04-01

    The aim of this study was to evaluate the effect of the primary tumor volume on prognosis in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy. Between August 2003 and April 2005, 112 patients with Stage I-IVB nasopharyngeal carcinoma treated by intensity-modulated radiation therapy were included. Measurement of the primary tumor volume was based on contrast-enhanced computed tomography scans before treatment. A receiver operating characteristics curve was used to determine the best cut-off point of the primary tumor volume. The mean primary tumor volume for 112 patients with nasopharyngeal carcinoma was 33.9 ± 28.7 ml. Within the framework of UICC T-staging, all patients were divided into four groups according to the primary tumor volume. We call it the volume stage (V1 50.55 ml). The 5-year overall survival rates for V1, V2, V3 and V4 were 88.5, 83.3, 82.4 and 54.5% (P = 0.014), respectively. The cumulative survival curves for V1, V2 and V3 were very close, but clearly separated from V4. In addition, Cox proportional hazards regression model analysis showed that a primary tumor volume >50 ml was an independent risk factor for radiotherapy (risk ratio = 3.485, P = 0.025). This study demonstrated that the primary tumor volume had significantly impacted on the prognosis of patients with nasopharyngeal carcinoma. We proposed that the primary tumor volume should be considered as an additional stage indicator in the new revision of the clinical stage of nasopharyngeal carcinoma.

  18. Tomotherapy for prostate adenocarcinoma: A report on acute toxicity

    International Nuclear Information System (INIS)

    Keiler, Louis; Dobbins, Donald; Kulasekere, Ravi; Einstein, Douglas

    2007-01-01

    Background and purpose: To analyze the impact of Tomotherapy (TOMO) intensity modulated radiotherapy (IMRT) on acute gastrointestinal (GI) and genitourinary (GU) toxicity in prostate cancer. Materials and methods: The records of 55 consecutively treated TOMO patients were reviewed. Additionally a well-matched group of 43 patients treated with LINAC-based step and shoot IMRT (LINAC) was identified. Acute toxicity was scored according to Radiation Therapy Oncology Group acute toxicity criterion. Results: The grade 2-3 acute GU toxicity rates for the TOMO vs. LINAC groups were 51% vs. 28% (p = 0.001). Acute grade 2 GI toxicity was 25% vs. 40% (p = 0.024), with no grade 3 GI toxicity in either group. In univariate analysis, androgen deprivation, prostate volume, pre-treatment urinary toxicity, and prostate dose homogeneity correlated with acute GI and GU toxicity. With multivariate analysis use of Tomotherapy, median bladder dose and bladder dose homogeneity remained significantly correlated with GU toxicity. Conclusions: Acute GI toxicity for prostate cancer is improved with Tomotherapy at a cost of increased acute GU toxicity possibly due to differences in bladder and prostate dose distribution

  19. Acute Toxicity After Image-Guided Intensity Modulated Radiation Therapy Compared to 3D Conformal Radiation Therapy in Prostate Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    Wortel, Ruud C.; Incrocci, Luca [Department of Radiation Oncology, Erasmus Medical Center Cancer Institute, Rotterdam (Netherlands); Pos, Floris J.; Lebesque, Joos V.; Witte, Marnix G.; Heide, Uulke A. van der; Herk, Marcel van [Department of Radiation Oncology, Netherlands Cancer Institute, Amsterdam (Netherlands); Heemsbergen, Wilma D., E-mail: w.heemsbergen@nki.nl [Department of Radiation Oncology, Netherlands Cancer Institute, Amsterdam (Netherlands)

    2015-03-15

    Purpose: Image-guided intensity modulated radiation therapy (IG-IMRT) allows significant dose reductions to organs at risk in prostate cancer patients. However, clinical data identifying the benefits of IG-IMRT in daily practice are scarce. The purpose of this study was to compare dose distributions to organs at risk and acute gastrointestinal (GI) and genitourinary (GU) toxicity levels of patients treated to 78 Gy with either IG-IMRT or 3D-CRT. Methods and Materials: Patients treated with 3D-CRT (n=215) and IG-IMRT (n=260) receiving 78 Gy in 39 fractions within 2 randomized trials were selected. Dose surface histograms of anorectum, anal canal, and bladder were calculated. Identical toxicity questionnaires were distributed at baseline, prior to fraction 20 and 30 and at 90 days after treatment. Radiation Therapy Oncology Group (RTOG) grade ≥1, ≥2, and ≥3 endpoints were derived directly from questionnaires. Univariate and multivariate binary logistic regression analyses were applied. Results: The median volumes receiving 5 to 75 Gy were significantly lower (all P<.001) with IG-IMRT for anorectum, anal canal, and bladder. The mean dose to the anorectum was 34.4 Gy versus 47.3 Gy (P<.001), 23.6 Gy versus 44.6 Gy for the anal canal (P<.001), and 33.1 Gy versus 43.2 Gy for the bladder (P<.001). Significantly lower grade ≥2 toxicity was observed for proctitis, stool frequency ≥6/day, and urinary frequency ≥12/day. IG-IMRT resulted in significantly lower overall RTOG grade ≥2 GI toxicity (29% vs 49%, respectively, P=.002) and overall GU grade ≥2 toxicity (38% vs 48%, respectively, P=.009). Conclusions: A clinically meaningful reduction in dose to organs at risk and acute toxicity levels was observed in IG-IMRT patients, as a result of improved technique and tighter margins. Therefore reduced late toxicity levels can be expected as well; additional research is needed to quantify such reductions.

  20. Predictors of Radiation Therapy–Related Gastrointestinal Toxicity From Anal Cancer Dose-Painted Intensity Modulated Radiation Therapy: Secondary Analysis of NRG Oncology RTOG 0529

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, Jeffrey R., E-mail: Jeffrey.R.Olsen@ucdenver.edu [University of Colorado Denver, Aurora, Colorado (United States); Moughan, Jennifer [NRG Oncology Statistics and Data Management Center, Philadelphia, Pennsylvania (United States); Myerson, Robert [Washington University, St. Louis, Missouri (United States); Abitbol, Andre [Baptist Hospital of Miami, Miami, Florida (United States); Doncals, Desiree E. [Summa Akron City Hospital accruals for Akron City Hospital, Akron, Ohio (United States); Johnson, Douglas [Florida Radiation Oncology Group–Baptist Regional, Jacksonville, Florida (United States); Schefter, Tracey E. [University of Colorado Denver, Aurora, Colorado (United States); Chen, Yuhchyau [University of Rochester Medical Center, Rochester, New York (United States); Fisher, Barbara [London Regional Cancer Program—University of Western Ontario, London, Ontario (Canada); Michalski, Jeff [Washington University, St. Louis, Missouri (United States); Narayan, Samir [Michigan Cancer Research Consortium CCOP, Ann Arbor, Michigan (United States); Chang, Albert [University of California San Francisco, San Francisco, California (United States); Crane, Christopher H. [Memorial Sloan Kettering Cancer Center, New York, New York (United States); Kachnic, Lisa [Vanderbilt University Medical Center, Nashville, Tennessee (United States)

    2017-06-01

    Purpose: NRG Oncology RTOG 0529 assessed the feasibility of dose-painted intensity modulated radiation therapy (DP-IMRT) to reduce the acute morbidity of chemoradiation with 5-fluorouracil (5FU) and mitomycin-C (MMC) for T2-4N0-3M0 anal cancer. This secondary analysis was performed to identify patient and treatment factors associated with acute and late gastrointestinal (GI) adverse events (AEs). Methods and Materials: NRG Oncology RTOG 0529 treatment plans were reviewed to extract dose-volume data for tightly contoured small bowel, loosely contoured anterior pelvic contents (APC), and uninvolved colon outside the target volume (UC). Univariate logistic regression was performed to evaluate association between volumes of each structure receiving doses ≥5 to 60 Gy (V5-V60) in 5-Gy increments between patients with and without grade ≥2 acute and late GI AEs, and grade ≥3 acute GI AEs. Additional patient and treatment factors were evaluated in multivariate logistic regression (acute AEs) or Cox proportional hazards models (late AEs). Results: Among 52 evaluable patients, grade ≥2 acute, grade ≥2 late, and grade ≥3 acute GI AEs were observed in 35, 17, and 10 patients, respectively. Trends (P<.05) toward statistically significant associations were observed between grade ≥2 acute GI AEs and small bowel dose (V20-V40), grade ≥2 late GI AEs and APC dose (V60), grade ≥3 acute GI AEs and APC dose (V5-V25), increasing age, tumor size >4 cm, and worse Zubrod performance status. Small bowel volumes of 186.0 cc, 155.0 cc, 41.0 cc, and 30.4 cc receiving doses greater than 25, 30, 35, and 40 Gy, respectively, correlated with increased risk of acute grade ≥2 GI AEs. Conclusions: Acute and late GI AEs from 5FU/MMC chemoradiation using DP-IMRT correlate with radiation dose to the small bowel and APC. Such associations will be incorporated in the dose-volume normal tissue constraint design for future NRG oncology anal cancer studies.

  1. Predictors of Radiation Therapy–Related Gastrointestinal Toxicity From Anal Cancer Dose-Painted Intensity Modulated Radiation Therapy: Secondary Analysis of NRG Oncology RTOG 0529

    International Nuclear Information System (INIS)

    Olsen, Jeffrey R.; Moughan, Jennifer; Myerson, Robert; Abitbol, Andre; Doncals, Desiree E.; Johnson, Douglas; Schefter, Tracey E.; Chen, Yuhchyau; Fisher, Barbara; Michalski, Jeff; Narayan, Samir; Chang, Albert; Crane, Christopher H.; Kachnic, Lisa

    2017-01-01

    Purpose: NRG Oncology RTOG 0529 assessed the feasibility of dose-painted intensity modulated radiation therapy (DP-IMRT) to reduce the acute morbidity of chemoradiation with 5-fluorouracil (5FU) and mitomycin-C (MMC) for T2-4N0-3M0 anal cancer. This secondary analysis was performed to identify patient and treatment factors associated with acute and late gastrointestinal (GI) adverse events (AEs). Methods and Materials: NRG Oncology RTOG 0529 treatment plans were reviewed to extract dose-volume data for tightly contoured small bowel, loosely contoured anterior pelvic contents (APC), and uninvolved colon outside the target volume (UC). Univariate logistic regression was performed to evaluate association between volumes of each structure receiving doses ≥5 to 60 Gy (V5-V60) in 5-Gy increments between patients with and without grade ≥2 acute and late GI AEs, and grade ≥3 acute GI AEs. Additional patient and treatment factors were evaluated in multivariate logistic regression (acute AEs) or Cox proportional hazards models (late AEs). Results: Among 52 evaluable patients, grade ≥2 acute, grade ≥2 late, and grade ≥3 acute GI AEs were observed in 35, 17, and 10 patients, respectively. Trends (P<.05) toward statistically significant associations were observed between grade ≥2 acute GI AEs and small bowel dose (V20-V40), grade ≥2 late GI AEs and APC dose (V60), grade ≥3 acute GI AEs and APC dose (V5-V25), increasing age, tumor size >4 cm, and worse Zubrod performance status. Small bowel volumes of 186.0 cc, 155.0 cc, 41.0 cc, and 30.4 cc receiving doses greater than 25, 30, 35, and 40 Gy, respectively, correlated with increased risk of acute grade ≥2 GI AEs. Conclusions: Acute and late GI AEs from 5FU/MMC chemoradiation using DP-IMRT correlate with radiation dose to the small bowel and APC. Such associations will be incorporated in the dose-volume normal tissue constraint design for future NRG oncology anal cancer studies.

  2. Performance characteristics of an independent dose verification program for helical tomotherapy

    Directory of Open Access Journals (Sweden)

    Isaac C. F. Chang

    2017-01-01

    Full Text Available Helical tomotherapy with its advanced method of intensity-modulated radiation therapy delivery has been used clinically for over 20 years. The standard delivery quality assurance procedure to measure the accuracy of delivered radiation dose from each treatment plan to a phantom is time-consuming. RadCalc®, a radiotherapy dose verification software, has released specifically for beta testing a module for tomotherapy plan dose calculations. RadCalc®'s accuracy for tomotherapy dose calculations was evaluated through examination of point doses in ten lung and ten prostate clinical plans. Doses calculated by the TomoHDA™ tomotherapy treatment planning system were used as the baseline. For lung cases, RadCalc® overestimated point doses in the lung by an average of 13%. Doses within the spinal cord and esophagus were overestimated by 10%. Prostate plans showed better agreement, with overestimations of 6% in the prostate, bladder, and rectum. The systematic overestimation likely resulted from limitations of the pencil beam dose calculation algorithm implemented by RadCalc®. Limitations were more severe in areas of greater inhomogeneity and less prominent in regions of homogeneity with densities closer to 1 g/cm3. Recommendations for RadCalc® dose calculation algorithms and anatomical representation were provided based on the results of the study.

  3. Investigation of conformal and intensity-modulated radiation therapy techniques to determine the absorbed fetal dose in pregnant patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Öğretici, Akın, E-mail: akinogretici@gmail.com; Akbaş, Uğur; Köksal, Canan; Bilge, Hatice

    2016-07-01

    The aim of this research was to investigate the fetal doses of pregnant patients undergoing conformal radiotherapy or intensity-modulated radiation therapy (IMRT) for breast cancers. An Alderson Rando phantom was chosen to simulate a pregnant patient with breast cancer who is receiving radiation therapy. This phantom was irradiated using the Varian Clinac DBX 600 system (Varian Medical System, Palo Alto, CA) linear accelerator, according to the standard treatment plans of both three-dimensional conformal radiation therapy (3-D CRT) and IMRT techniques. Thermoluminescent dosimeters were used to measure the irradiated phantom's virtually designated uterus area. Thermoluminescent dosimeter measurements (in the phantom) revealed that the mean cumulative fetal dose for 3-D CRT is 1.39 cGy and for IMRT it is 8.48 cGy, for a pregnant breast cancer woman who received radiation treatment of 50 Gy. The fetal dose was confirmed to increase by 70% for 3-D CRT and 40% for IMRT, if it is closer to the irradiated field by 5 cm. The mean fetal dose from 3-D CRT is 1.39 cGy and IMRT is 8.48 cGy, consistent with theoretic calculations. The IMRT technique causes the fetal dose to be 5 times more than that of 3-D CRT. Theoretic knowledge concerning the increase in the peripheral doses as the measurements approached the beam was also practically proven.

  4. Stereotactic body radiation therapy via helical tomotherapy to replace brachytherapy for brachytherapy-unsuitable cervical cancer patients – a preliminary result

    Directory of Open Access Journals (Sweden)

    Hsieh CH

    2013-02-01

    months 11, 14, and 25, respectively. One stage IVA patient experienced fistula formation in month 3.Conclusion: SBRT via HT provides the possibility for treatment of locally advanced cervical cancer in patients who are unsuitable for brachytherapy. Long-term follow up and enrollment of more such patients to receive SBRT via the HT technique are warranted.Keywords: biological equivalent dose, complication, image guidance, intensity modulated radiation therapy, rectal bleeding

  5. Intensity Modulated Radiation Therapy With Simultaneous Integrated Boost in Patients With Brain Oligometastases: A Phase 1 Study (ISIDE-BM-1)

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Marica [Radiotherapy Unit, Fondazione di Ricerca e Cura “Giovanni Paolo II,” Catholic University of Sacred Heart, Campobasso (Italy); Chiesa, Silvia [Department of Radiotherapy, Fondazione Policlinico Universitario “A. Gemelli,” Catholic University of Sacred Heart, Rome (Italy); Macchia, Gabriella, E-mail: gmacchia@rm.unicatt.it [Radiotherapy Unit, Fondazione di Ricerca e Cura “Giovanni Paolo II,” Catholic University of Sacred Heart, Campobasso (Italy); Cilla, Savino [Medical Physics Unit, Fondazione di Ricerca e Cura “Giovanni Paolo II,” Catholic University of Sacred Heart, Campobasso (Italy); Bertini, Federica [Radiation Oncology Center, Department of Experimental, Diagnostic and Specialty Medicine, S. Orsola-Malpighi Hospital, University of Bologna, Bologna (Italy); Frezza, Giovanni [Radiotherapy Department, Ospedale Bellaria, Bologna (Italy); Farioli, Andrea [Department of Medical and Surgical Sciences, S. Orsola-Malpighi Hospital, University of Bologna, Bologna (Italy); Cammelli, Silvia [Radiation Oncology Center, Department of Experimental, Diagnostic and Specialty Medicine, S. Orsola-Malpighi Hospital, University of Bologna, Bologna (Italy); Balducci, Mario [Department of Radiotherapy, Fondazione Policlinico Universitario “A. Gemelli,” Catholic University of Sacred Heart, Rome (Italy); Ianiro, Anna [Medical Physics Unit, Fondazione di Ricerca e Cura “Giovanni Paolo II,” Catholic University of Sacred Heart, Campobasso (Italy); Angelini, Anna Lisa; Compagnone, Gaetano [Medical Physics Unit, S. Orsola-Malpighi Hospital, Bologna (Italy); and others

    2017-01-01

    Purpose: To investigate the maximum tolerated dose of intensity modulated radiation therapy simultaneous integrated boost whole-brain radiation therapy for palliative treatment of patients with <5 brain metastases using a standard linear accelerator. Materials and Methods: The whole brain plus 3-mm margin was defined as the planning target volume (PTV{sub wb}), whereas each brain metastasis, defined as the contrast-enhancing tumor on MRI T1 scans, plus a 3-mm isotropic margin, was defined as metastases PTV (PTV{sub m}). Radiation therapy was delivered in 10 daily fractions (2 weeks). Only the dose to PTV{sub m} was progressively increased in the patient cohorts (35 Gy, 40 Gy, 45 Gy, 50 Gy), whereas the PTV{sub wb} was always treated with 30 Gy (3 Gy per fraction) in all patients. The dose-limiting toxicity was evaluated providing that 3 months of follow-up had occurred after the treatment of a 6-patient cohort. Results: Thirty patients were enrolled in the study (dose PTV{sub m}: 35 Gy, 8 patients; 40 Gy, 6 patients; 45 Gy, 6 patients; 50 Gy, 10 patients). The number of treated brain metastases was 1 in 18 patients, 2 in 5 patients, 3 in 6 patients, and 4 in 1 patient. Three patients experienced dose-limiting toxicity: 1 patient at dose level 2 presented grade 3 (G3) skin toxicity; 1 patient at dose level 4 presented G3 neurologic toxicity; and 1 patient at the same level showed brain hemorrhage. Most patients showed G1 to 2 acute toxicity, in most cases skin (n=19) or neurologic (n=10). Twenty-seven were evaluable for response: 6 (22%) stable disease, 18 (67%) partial response, and 3 (11%) complete response. Median survival and 1-year overall survival were 12 months and 53%, respectively. No patient showed late toxicity. Conclusions: In this first prospective trial on the use of intensity modulated radiation therapy simultaneous integrated boost delivered with a standard linear accelerator in patients with brain oligometastases, a boost dose up to 50

  6. Split-field vs extended-field intensity-modulated radiation therapy plans for oropharyngeal cancer: Which spares the larynx? Which spares the thyroid?

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Yao; Chen, Josephine [Department of Radiation Oncology, University of California, San Francisco, San Francisco, CA (United States); Leary, Celeste I. [Department of Radiation Medicine, Oregon Health Sciences University, Portland, OR (United States); Shugard, Erin [Department of Radiation Oncology, University of California, San Francisco, San Francisco, CA (United States); Yom, Sue S., E-mail: yoms@radonc.ucsf.edu [Department of Radiation Oncology, University of California, San Francisco, San Francisco, CA (United States); Department of Otolaryngology—Head and Neck Surgery, University of California, San Francisco, San Francisco, CA (United States)

    2016-07-01

    Radiation of the low neck can be accomplished using split-field intensity-modulated radiation therapy (sf-IMRT) or extended-field intensity-modulated radiation therapy (ef-IMRT). We evaluated the effect of these treatment choices on target coverage and thyroid and larynx doses. Using data from 14 patients with cancers of the oropharynx, we compared the following 3 strategies for radiating the low neck: (1) extended-field IMRT, (2) traditional split-field IMRT with an initial cord-junction block to 40 Gy, followed by a full-cord block to 50 Gy, and (3) split-field IMRT with a full-cord block to 50 Gy. Patients were planned using each of these 3 techniques. To facilitate comparison, extended-field plans were normalized to deliver 50 Gy to 95% of the neck volume. Target coverage was assessed using the dose to 95% of the neck volume (D{sub 95}). Mean thyroid and larynx doses were computed. Extended-field IMRT was used as the reference arm; the mean larynx dose was 25.7 ± 7.4 Gy, and the mean thyroid dose was 28.6 ± 2.4 Gy. Split-field IMRT with 2-step blocking reduced laryngeal dose (mean larynx dose 15.2 ± 5.1 Gy) at the cost of a moderate reduction in target coverage (D{sub 95} 41.4 ± 14 Gy) and much higher thyroid dose (mean thyroid dose 44.7 ± 3.7 Gy). Split-field IMRT with initial full-cord block resulted in greater laryngeal sparing (mean larynx dose 14.2 ± 5.1 Gy) and only a moderately higher thyroid dose (mean thyroid dose 31 ± 8 Gy) but resulted in a significant reduction in target coverage (D{sub 95} 34.4 ± 15 Gy). Extended-field IMRT comprehensively covers the low neck and achieves acceptable thyroid and laryngeal sparing. Split-field IMRT with a full-cord block reduces laryngeal doses to less than 20 Gy and spares the thyroid, at the cost of substantially reduced coverage of the low neck. Traditional 2-step split-field IMRT similarly reduces the laryngeal dose but also reduces low-neck coverage and delivers very high doses to the thyroid.

  7. Qualitative risk analysis in the process of treatment in radiation oncology for the steps performed by the technician/technologist in intensity modulated radiotherapy (lMRT)

    International Nuclear Information System (INIS)

    Teixeira, Flavia C.S.; Faria, Alessandra L.; Pereira, Danielle P.S.; Silva, Fabiana M.I.

    2013-01-01

    The efficacy of radiation therapy is to eradicate the tumor while preserving the integrity of normal tissues. Technological advances have allowed to develop techniques capable of modulating doses delivered to the target volume, providing more effective treatments. However, the operational complexity of these techniques makes the benefits offered are directly proportional to the chances of occurrences of serious errors. The objective of this work is to analyze the steps performed by the technician/technologist in Intensity Modulated Radiotherapy (IMRT), to detect possible errors in order to determine ways to mitigate them. After literature regarding errors in the radiation therapy, a prospective analysis was performed in the first half of 2012 in a radiation clinic located in the city of Rio de Janeiro, in which 11 technicians/technologists contributed to the survey data analysis. The method of risk analysis Failure Mode and Effects Analysis was used for prospective analysis of accidents/incidents, with respect to a qualitative assessment . The method allowed mapping 16 steps performed by technicians/technologists in the treatments with IMRT, identifying possible failures and their causes allowing to find ways to avoid possible errors. This analysis helped to confirm that the qualification and continuing education of technicians/technologists, allied to implement quality assurance programs and a computerized management can make a tool capable of IMRT to achieve the greatest challenge of radiotherapy. (author)

  8. Hypoxia imaging with [F-18] FMISO-PET in head and neck cancer: Potential for guiding intensity modulated radiation therapy in overcoming hypoxia-induced treatment resistance

    International Nuclear Information System (INIS)

    Hendrickson, Kristi; Phillips, Mark; Smith, Wade; Peterson, Lanell; Krohn, Kenneth; Rajendran, Joseph

    2011-01-01

    Background and purpose: Positron emission tomography (PET) imaging with [F-18] fluoromisonidazole (FMISO) has been validated as a hypoxic tracer . Head and neck cancer exhibits hypoxia, inducing aggressive biologic traits that impart resistance to treatment. Delivery of modestly higher radiation doses to tumors with stable areas of chronic hypoxia can improve tumor control . Advanced radiation treatment planning (RTP) and delivery techniques such as intensity modulated radiation therapy (IMRT) can deliver higher doses to a small volume without increasing morbidity. We investigated the utility of co-registered FMISO-PET and CT images to develop clinically feasible RTPs with higher tumor control probabilities (TCP). Materials and methods: FMISO-PET images were used to determine hypoxic sub-volumes for boost planning. Example plans were generated for 10 of the patients in the study who exhibited significant hypoxia. We created an IMRT plan for each patient with a simultaneous integrated boost (SIB) to the hypoxic sub-volumes. We also varied the boost for two patients. Result: A significant (mean 17%, median 15%) improvement in TCP is predicted when the modest additional boost dose to the hypoxic sub-volume is included. Conclusion: Combined FMISO-PET imaging and IMRT planning permit delivery of higher doses to hypoxic regions, increasing the predicted TCP (mean 17%) without increasing expected complications.

  9. Therapeutic benefits in grid irradiation on Tomotherapy for bulky, radiation-resistant tumors.

    Science.gov (United States)

    Narayanasamy, Ganesh; Zhang, Xin; Meigooni, Ali; Paudel, Nava; Morrill, Steven; Maraboyina, Sanjay; Peacock, Loverd; Penagaricano, Jose

    2017-08-01

    Spatially fractionated radiation therapy (SFRT or grid therapy) has proven to be effective in management of bulky tumors. The aim of this project is to study the therapeutic ratio (TR) of helical Tomotherapy (HT)-based grid therapy using linear-quadratic cell survival model. HT-based grid (or HT-GRID) plan was generated using a patient-specific virtual grid pattern of high-dose cylindrical regions using MLCs. TR was defined as the ratio of normal tissue surviving fraction (SF) under HT-GRID irradiation to an open debulking field of an equivalent dose that result in the same tumor cell SF. TR was estimated from DVH data on ten HT-GRID patient plans with deep seated, bulky tumor. Dependence of the TR values on radiosensitivity of the tumor cells and prescription dose was analyzed. The mean ± standard deviation (SD) of TR was 4.0 ± 0.7 (range: 3.1-5.5) for the 10 patients with single fraction maximum dose of 20 Gy to GTV assuming a tumor cell SF at 2 Gy (SF2 t ) value of 0·5. In addition, the mean ± SD of TR values for SF2 t values of 0.3 and 0.7 were found to be 1 ± 0.1 and 18.0 ± 5.1, respectively. Reducing the prescription dose to 15 and 10 Gy lowered the respective TR values to 2.0 ± 0.2 and 1.2 ± 0.04 for a SF2 t value of 0.5. HT-GRID therapy demonstrates a significant therapeutic advantage over uniform dose from an open field irradiation for the same tumor cell kill. TR increases with the radioresistance of the tumor cells and with prescription dose.

  10. Synchronous Supraglottic and Esophageal Squamous Cell Carcinomas Treated with a Monoisocentric Hybrid Intensity-Modulated Radiation Technique

    Directory of Open Access Journals (Sweden)

    Christian L. Barney

    2018-01-01

    Full Text Available Risk factors for squamous cell carcinomas (SCCs of the head and neck (HN and esophagus are similar. As such, synchronous primary tumors in these areas are not entirely uncommon. Definitive chemoradiation (CRT is standard care for locally advanced HNSCC and is a preferred option for inoperable esophageal SCC. Simultaneous treatment of both primaries with CRT can present technical challenges. We report a case of synchronous supraglottic and esophageal SCC primary tumors, highlighting treatment with a monoisocentric hybrid radiation technique and normal tissue toxicity considerations.

  11. Patterns of Recurrence in Electively Irradiated Lymph Node Regions After Definitive Accelerated Intensity Modulated Radiation Therapy for Head and Neck Squamous Cell Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Bosch, Sven van den, E-mail: sven.vandenbosch@radboudumc.nl; Dijkema, Tim; Verhoef, Lia C.G.; Zwijnenburg, Ellen M.; Janssens, Geert O.; Kaanders, Johannes H.A.M.

    2016-03-15

    Purpose: To provide a comprehensive risk assessment on the patterns of recurrence in electively irradiated lymph node regions after definitive radiation therapy for head and neck cancer. Methods and Materials: Two hundred sixty-four patients with stage cT2-4N0-2M0 squamous cell carcinoma of the oropharynx, larynx, or hypopharynx treated with accelerated intensity modulated radiation therapy between 2008 and 2012 were included. On the radiation therapy planning computed tomography (CT) scans from all patients, 1166 lymph nodes (short-axis diameter ≥5 mm) localized in the elective volume were identified and delineated. The exact sites of regional recurrences were reconstructed and projected on the initial radiation therapy planning CT scan by performing coregistration with diagnostic imaging of the recurrence. Results: The actuarial rate of recurrence in electively irradiated lymph node regions at 2 years was 5.1% (95% confidence interval 2.4%-7.8%). Volumetric analysis showed an increased risk of recurrence with increasing nodal volume. Receiver operating characteristic analysis demonstrated that the summed long- and short-axis diameter is a good alternative for laborious volume calculations, using ≥17 mm as cut-off (hazard ratio 17.8; 95% confidence interval 5.7-55.1; P<.001). Conclusions: An important risk factor was identified that can help clinicians in the pretreatment risk assessment of borderline-sized lymph nodes. Not overtly pathologic nodes with a summed diameter ≥17 mm may require a higher than elective radiation therapy dose. For low-risk elective regions (all nodes <17 mm), the safety of dose de-escalation below the traditional 45 to 50 Gy should be investigated.

  12. Prospective study of sequential volumetric changes of parotid gland in early oropharyngeal carcinoma patients treated by intensity-modulated radiation therapy: An institutional experience.

    Science.gov (United States)

    Patel, Pooja Nandwani; Goyal, Sumit; Shah, Anand; Gohel, Mehul; Suryanarayana, Unnikrishnan

    2018-01-01

    During course of radiation therapy, anatomical variations occur risking overdose of parotid gland. We tried to quantify volume of parotid gland and mean dose to parotid gland after every 10 fractions (#). We conducted the prospective study from July 2016 to May 2017 in 25 patients of early-stage oropharyngeal carcinoma. Patients had Karnofsy Performance Score of 80-100, median age was 54 years, and 18 patients were males. Patients were planned with intensity-modulated radiation therapy planning with dose as 66 Gy/30# to planning target volume (PTV) including primary and 54 Gy/30# to PTV-nodal including elective neck irradiation. After each 10#, replanning was done, and variations in parotid volume were studied including D mean (mean dose to parotids) and D 50 (the dose delivered to 50% of volume). Other tumor characteristic like PTV of primary was also assessed and minimum PTV volume covered by 95% isodose line was kept as 95%. Average parotid volumes decreased by the mean value of 10% and 6% for the left and right parotids, respectively, and PTV of primary target decreased by mean of 13%. The difference in D mean doses to parotid glands was 32% and 42% and difference in D 50 dose was 30% and 35% on the left and right side, respectively. The parotid volumes differ considerably during adaptive planning done after every ten fractions. These differences in parotid volumes and doses received to parotid glands play a significant role in the risk of xerostomia observed during later follow-up.

  13. Intensity-Modulated Radiation Therapy with Noncoplanar Beams for Treatment of Prostate Cancer in Patients with Bilateral Hip Prosthesis-A Case Study

    International Nuclear Information System (INIS)

    Brooks, Chris; Cheung, Rex Min; Kudchadker, Rajat J.

    2010-01-01

    Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning is further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer patient with bilateral hip prostheses. The treatment was planned for 75.6 Gy using a 7-field coplanar approach and a noncoplanar arrangement, with all fields avoiding entrance though the prostheses. Our results indicate that, compared with the coplanar plan, the noncoplanar plan delivers the prescribed dose to the target with a slightly better conformality and sparing of rectal tissue versus the coplanar plan.

  14. Optimal starting gantry angles using equiangular-spaced beams with intensity modulated radiation therapy for prostate cancer on RTOG 0126: A clinical study of 5 and 7 fields

    International Nuclear Information System (INIS)

    Potrebko, Peter S.; McCurdy, Boyd M.C.; Butler, James B.; El-Gubtan, Adel S.; Nugent, Zoann

    2007-01-01

    Background and Purpose: To investigate the effects of starting gantry angle and number of equiangular-spaced beams for prostate cancer radiotherapy on the Radiation Therapy Oncology Group (RTOG) 0126 protocol using intensity-modulated radiation therapy (IMRT). Materials and methods: Ten localized prostate cancer patients were prescribed to 79.2 Gy in 44 fractions. Static IMRT plans using five and seven equiangular-spaced beams were generated. The starting gantry angles were incremented by 5 o resulting in 15 (5 beams) and 11 (7 beams) plans per patient. Constant target coverage was ensured for all plans in order to isolate the variation in the rectal and bladder metrics as a function of starting gantry angle. Results: The variation with starting gantry angle in rectal metrics using 5 beams was statistically significant (p o and 50 o . Statistically insignificant differences were observed for the bladder metrics using 5 beams. There was little dosimetric variation in the rectal and bladder metrics with 7 beams. Nearly equivalent rectal V 75 Gy was achieved between 5 optimal equiangular-spaced beams starting at 20 o (class solution) and 7 equiangular-spaced beams starting at 0 o for most patients. Conclusions: The use of an optimal starting gantry angle for 5 equiangular-spaced beams, as indicated by a class solution in this study, will facilitate rectal sparing and can produce plans that are equivalent to those employing 7 equiangular-spaced beams

  15. Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Jeffrey M. [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Handorf, Elizabeth A. [Department of Biostatistics, Fox Chase Cancer Center, Philadelphia, PA (United States); Price, Robert A.; Cherian, George [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Buyyounouski, Mark K. [Department of Radiation Oncology, Stanford University, Stanford, CA (United States); Chen, David Y.; Kutikov, Alexander [Department of Urologic Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Johnson, Matthew E.; Ma, Chung-Ming Charlie [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Horwitz, Eric M., E-mail: eric.horwitz@fccc.edu [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States)

    2015-10-01

    A small decrease in testosterone level has been documented after prostate irradiation, possibly owing to the incidental dose to the testes. Testicular doses from prostate external beam radiation plans with either intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) were calculated to investigate any difference. Testicles were contoured for 16 patients being treated for localized prostate cancer. For each patient, 2 plans were created: 1 with IMRT and 1 with VMAT. No specific attempt was made to reduce testicular dose. Minimum, maximum, and mean doses to the testicles were recorded for each plan. Of the 16 patients, 4 received a total dose of 7800 cGy to the prostate alone, 7 received 8000 cGy to the prostate alone, and 5 received 8000 cGy to the prostate and pelvic lymph nodes. The mean (range) of testicular dose with an IMRT plan was 54.7 cGy (21.1 to 91.9) and 59.0 cGy (25.1 to 93.4) with a VMAT plan. In 12 cases, the mean VMAT dose was higher than the mean IMRT dose, with a mean difference of 4.3 cGy (p = 0.019). There was a small but statistically significant increase in mean testicular dose delivered by VMAT compared with IMRT. Despite this, it unlikely that there is a clinically meaningful difference in testicular doses from either modality.

  16. Intensity Modulated Radiation Therapy for Early-Stage Primary Gastric Diffuse Large B-Cell Lymphoma: Dosimetric Analysis, Clinical Outcome, and Quality of Life

    International Nuclear Information System (INIS)

    Liu, Xin; Fang, Hui; Tian, Yuan; Wang, Wei-Hu; Song, Yong-Wen; Wang, Shu-Lian; Liu, Yue-Ping; He, Xiao-Hui; Dong, Mei; Ren, Hua; Jin, Jing; Li, Ye-Xiong

    2016-01-01

    Purpose: To evaluate the dosimetric superiority, efficacy, toxicity, and quality of life (QOL) data of intensity modulated radiation therapy (IMRT) in patients with primary gastric diffuse large B-cell lymphoma (PG-DLBCL). Methods and Materials: Forty-six consecutive patients with early-stage PG-DLBCL underwent IMRT after chemotherapy. The majority of patients (61.5%) were subclassified as the non-germinal center B cell–like subtype. Dosimetric parameters of the planning target volume (PTV) and organs at risk were assessed. Survival rates were depicted with the Kaplan-Meier method and compared with the log-rank test. Quality of life was evaluated using the QLQ-C30-STO22 questionnaires at the last follow-up contact. Results: The median PTV mean dose was 41.6 Gy. Only 0.73% of the PTV received <95% of the prescribed dose, indicating excellent target coverage. The median kidney V20 and liver V30 were 14.1% and 16.1%, respectively. The 5-year overall survival (OS), progression-free survival, and locoregional control rates for all patients were 80.4%, 75.0%, and 93.2%, respectively. Stage, lactate dehydrogenase level, and immunophenotype were significant prognostic factors for OS, and only stage was a significant factor for locoregional control. Consolidation IMRT in patients with complete response after chemotherapy resulted in significantly better OS and progression-free survival than salvage IMRT in patients with non-complete response. Two of 8 patients who had chronic liver disease experienced grade 4 or grade 5 acute hepatic failure after 4 to 5 cycles of rituximab-based chemotherapy and IMRT (40 Gy). No other serious acute or late toxicity was observed. The long-term global and functional QOL scales were excellent, with negligible symptom scales. Conclusions: Intensity modulated radiation therapy yielded excellent target coverage and critical tissue sparing and achieved favorable outcomes with acceptable toxicity and good long-term QOL in early-stage PG-DLBCL.

  17. Intensity Modulated Radiation Therapy for Early-Stage Primary Gastric Diffuse Large B-Cell Lymphoma: Dosimetric Analysis, Clinical Outcome, and Quality of Life

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xin; Fang, Hui; Tian, Yuan; Wang, Wei-Hu; Song, Yong-Wen; Wang, Shu-Lian; Liu, Yue-Ping [Department of Radiation Oncology, Cancer Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing (China); He, Xiao-Hui; Dong, Mei [Department of Medical Oncology, Cancer Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing (China); Ren, Hua; Jin, Jing [Department of Radiation Oncology, Cancer Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing (China); Li, Ye-Xiong, E-mail: yexiong@yahoo.com [Department of Radiation Oncology, Cancer Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing (China)

    2016-06-01

    Purpose: To evaluate the dosimetric superiority, efficacy, toxicity, and quality of life (QOL) data of intensity modulated radiation therapy (IMRT) in patients with primary gastric diffuse large B-cell lymphoma (PG-DLBCL). Methods and Materials: Forty-six consecutive patients with early-stage PG-DLBCL underwent IMRT after chemotherapy. The majority of patients (61.5%) were subclassified as the non-germinal center B cell–like subtype. Dosimetric parameters of the planning target volume (PTV) and organs at risk were assessed. Survival rates were depicted with the Kaplan-Meier method and compared with the log-rank test. Quality of life was evaluated using the QLQ-C30-STO22 questionnaires at the last follow-up contact. Results: The median PTV mean dose was 41.6 Gy. Only 0.73% of the PTV received <95% of the prescribed dose, indicating excellent target coverage. The median kidney V20 and liver V30 were 14.1% and 16.1%, respectively. The 5-year overall survival (OS), progression-free survival, and locoregional control rates for all patients were 80.4%, 75.0%, and 93.2%, respectively. Stage, lactate dehydrogenase level, and immunophenotype were significant prognostic factors for OS, and only stage was a significant factor for locoregional control. Consolidation IMRT in patients with complete response after chemotherapy resulted in significantly better OS and progression-free survival than salvage IMRT in patients with non-complete response. Two of 8 patients who had chronic liver disease experienced grade 4 or grade 5 acute hepatic failure after 4 to 5 cycles of rituximab-based chemotherapy and IMRT (40 Gy). No other serious acute or late toxicity was observed. The long-term global and functional QOL scales were excellent, with negligible symptom scales. Conclusions: Intensity modulated radiation therapy yielded excellent target coverage and critical tissue sparing and achieved favorable outcomes with acceptable toxicity and good long-term QOL in early-stage PG-DLBCL.

  18. Different setup errors assessed by weekly cone-beam computed tomography on different registration in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy

    Directory of Open Access Journals (Sweden)

    Su JQ

    2015-09-01

    Full Text Available Jiqing Su,1,2,* Wen Chen,2,* Huiyun Yang,2 Jidong Hong,2 Zijian Zhang,2 Guangzheng Yang,2 Li Li,2 Rui Wei21Department of Oncology, Changsha Central Hospital, Changsha, 2Department of Oncology, Xiangya Hospital, Central South University, Changsha, People’s Republic of China*These authors contributed equally to this workAbstract: The study aimed to investigate the difference of setup errors on different registration in the treatment of nasopharyngeal carcinoma based on weekly cone-beam computed tomography (CBCT. Thirty nasopharyngeal cancer patients scheduled to undergo intensity-modulated radiotherapy (IMRT were prospectively enrolled in the study. Each patient had a weekly CBCT before radiation therapy. In the entire study, 201 CBCT scans were obtained. The scans were registered to the planning CT to determine the difference of setup errors on different registration sites. Different registration sites were represented by bony landmarks. Nasal septum and pterygoid process represent head, cervical vertebrae 1–3 represent upper neck, and cervical vertebrae 4–6 represent lower neck. Patient positioning errors were recorded in the right–left (RL, superior–inferior (SI, and anterior–posterior (AP directions over the course of radiotherapy. Planning target volume margins were calculated from the systematic and random errors. In this study, we can make a conclusion that there are setup errors in RL, SI, and AP directions of nasopharyngeal carcinoma patients undergoing IMRT. In addition, the head and neck setup error has the difference, with statistical significance, while patient setup error of neck is greater than that of head during the course of radiotherapy. In our institution, we recommend a planning target volume margin of 3.0 mm in RL direction, 1.3 mm in SI direction, and 2.6 mm in AP direction for nasopharyngeal cancer patients undergoing IMRT with weekly CBCT scans.Keywords: cone-beam computed tomography, setup error, PTV

  19. Hemithoracic Intensity Modulated Radiation Therapy After Pleurectomy/Decortication for Malignant Pleural Mesothelioma: Toxicity, Patterns of Failure, and a Matched Survival Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chance, William W. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Rice, David C. [Department of Thoracic and Cardiovascular Surgery, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Allen, Pamela K. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Tsao, Anne S. [Department of Thoracic/Head and Neck Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Fontanilla, Hiral P. [Princeton Radiation Oncology, Monroe Township, New Jersey (United States); Liao, Zhongxing; Chang, Joe Y.; Tang, Chad; Pan, Hubert Y.; Welsh, James W. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Mehran, Reza J. [Department of Thoracic and Cardiovascular Surgery, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Gomez, Daniel R., E-mail: dgomez@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2015-01-01

    Purpose: To investigate safety, efficacy, and recurrence after hemithoracic intensity modulated radiation therapy after pleurectomy/decortication (PD-IMRT) and after extrapleural pneumonectomy (EPP-IMRT). Methods and Materials: In 2009-2013, 24 patients with mesothelioma underwent PD-IMRT to the involved hemithorax to a dose of 45 Gy, with an optional integrated boost; 22 also received chemotherapy. Toxicity was scored with the Common Terminology Criteria for Adverse Events v4.0. Pulmonary function was compared at baseline, after surgery, and after IMRT. Kaplan-Meier analysis was used to calculate overall survival (OS), progression-free survival (PFS), time to locoregional failure, and time to distant metastasis. Failures were in-field, marginal, or out of field. Outcomes were compared with those of 24 patients, matched for age, nodal status, performance status, and chemotherapy, who had received EPP-IMRT. Results: Median follow-up time was 12.2 months. Grade 3 toxicity rates were 8% skin and 8% pulmonary. Pulmonary function declined from baseline to after surgery (by 21% for forced vital capacity, 16% for forced expiratory volume in 1 second, and 19% for lung diffusion of carbon monoxide [P for all = .01]) and declined still further after IMRT (by 31% for forced vital capacity [P=.02], 25% for forced expiratory volume in 1 second [P=.01], and 30% for lung diffusion of carbon monoxide [P=.01]). The OS and PFS rates were 76% and 67%, respectively, at 1 year and 56% and 34% at 2 years. Median OS (28.4 vs 14.2 months, P=.04) and median PFS (16.4 vs 8.2 months, P=.01) favored PD-IMRT versus EPP-IMRT. No differences were found in grade 4-5 toxicity (0 of 24 vs 3 of 24, P=.23), median time to locoregional failure (18.7 months vs not reached, P not calculable), or median time to distant metastasis (18.8 vs 11.8 months, P=.12). Conclusions: Hemithoracic intensity modulated radiation therapy after pleurectomy/decortication produced little high-grade toxicity but

  20. Analysis of the absorbed dose in skin for head and neck intensity modulated radiation therapy treatments; Analisis de la dosis absorbida en piel en tratamientos de radioterapia de intensidad modulada en cabeza y cuello

    Energy Technology Data Exchange (ETDEWEB)

    Llorente Manso, M.; Vicente Toribio, T.

    2009-07-01

    Intensity Modulated Radiation Therapy is becoming a common technique for treatment of head and neck tumours. The use of inverse planning techniques can lead to an unwanted skin dose and toxicity increase. In this study we present a quantitative evaluation of such phenomenon and propose an optimization method for skin dose reduction to the level usual in conventional Conformal Radiotherapy. (Author) 10 refs.

  1. Assessment of organ dose reduction and secondary cancer risk associated with the use of proton beam therapy and intensity modulated radiation therapy in treatment of neuroblastomas

    International Nuclear Information System (INIS)

    Fuji, Hiroshi; Harada, Hideyuki; Asakura, Hirofumi; Nishimura, Tetsuo; Schneider, Uwe; Ishida, Yuji; Konno, Masahiro; Yamashita, Haruo; Kase, Yuki; Murayama, Shigeyuki; Onoe, Tsuyoshi; Ogawa, Hirofumi

    2013-01-01

    To compare proton beam therapy (PBT) and intensity-modulated radiation therapy (IMRT) with conformal radiation therapy (CRT) in terms of their organ doses and ability to cause secondary cancer in normal organs. Five patients (median age, 4 years; range, 2–11 years) who underwent PBT for retroperitoneal neuroblastoma were selected for treatment planning simulation. Four patients had stage 4 tumors and one had stage 2A tumor, according to the International Neuroblastoma Staging System. Two patients received 36 Gy, two received 21.6 Gy, and one received 41.4 Gy of radiation. The volume structures of these patients were used for simulations of CRT and IMRT treatment. Dose–volume analyses of liver, stomach, colon, small intestine, pancreas, and bone were performed for the simulations. Secondary cancer risks in these organs were calculated using the organ equivalent dose (OED) model, which took into account the rates of cell killing, repopulation, and the neutron dose from the treatment machine. In all evaluated organs, the mean dose in PBT was 20–80% of that in CRT. IMRT also showed lower mean doses than CRT for two organs (20% and 65%), but higher mean doses for the other four organs (110–120%). The risk of secondary cancer in PBT was 24–83% of that in CRT for five organs, but 121% of that in CRT for pancreas. The risk of secondary cancer in IMRT was equal to or higher than CRT for four organs (range 100–124%). Low radiation doses in normal organs are more frequently observed in PBT than in IMRT. Assessments of secondary cancer risk showed that PBT reduces the risk of secondary cancer in most organs, whereas IMRT is associated with a higher risk than CRT

  2. Deep-Inspiration Breath-Hold Intensity Modulated Radiation Therapy to the Mediastinum for Lymphoma Patients: Setup Uncertainties and Margins.

    Science.gov (United States)

    Aristophanous, Michalis; Chi, Pai-Chun M; Kao, Jeremy; Williamson, Ryan; Tung, Sam; Andraos, Therese; Milgrom, Sarah A; Pinnix, Chelsea C; Dabaja, Bouthaina S

    2018-01-01

    Patient setup for treating large target volumes can be challenging. In the present study, we measured the local uncertainties in the treatment of mediastinal lymphoma and investigated the need for region-specific planning target volume (PTV) margins. The data from 30 patients who had undergone radiation therapy for mediastinal lymphoma were retrospectively analyzed. A computed tomography (CT)-on-rails (CTOR) system in the treatment room was used for daily image guidance. The total PTV was split into 6 regions: neck, supraclavicular fossa, axilla, mediastinum, upper heart, and lower heart. The total PTV and the 6 local regions were separately aligned to the planning CT scan using automatic rigid registration. The residual local errors using 3 setup strategies were investigated: no image guidance, CTOR setup to total PTV, and simulated cone beam CT setup to the mediastinum. Errors were recorded in the anteroposterior, superoinferior, and right-left directions separately. Using the residual error calculations, the margins required to cover 95% of the clinical target volume for 90% of the patients was estimated. For each patient, 12 to 21 days of daily CTOR data were available for analysis. The residual errors for the total PTV and mediastinum setups were both smaller than those with no image guidance. The lower heart region had more uncertainty with all 3 setup strategies. Margin analysis revealed that the magnitude of the margin is dependent on the imaging strategy, direction, and local region inside the PTV. Margins >7 mm are necessary to account for uncertainty in the neck, lower heart, and axilla regions even under daily CT guidance. Setup uncertainties in the mediastinum are not uniform and are dependent on target location and imaging strategy. However, with the appropriate margin, we can target regions that might not be visualized with the available on-board imager system. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Position modification and actual radiation dose in parotids for head and neck cancers treated with TomoTherapy

    International Nuclear Information System (INIS)

    Jiang Huayong; Zhang Yongqian; Wang Yadi; Xu Weidong; Gao Junmao; Zhang Fuli; Yao Bo

    2014-01-01

    Objective: To analyze the impact of parotid's position and volume changing on radiation dose for head and neck cancer treated with TomoTherapy. Methods: Totally 12 patients with head and neck cancer were treated with TomoTherapy. Before the treatment, the dose distribution was recalculated with MVCT images, which would obtain the parameters of position, volume and actual radiation dose for parotids. Results: The volume of parotids in Plan2 was significantly lower than in Plan1, and the percentage reduction was 29.06% and 31.78% for left and right parotid, respectively (Z = 6.77, 3.06, P < 0.05). Distance between the COM(center of mass) of parotids and the midline of body was significantly smaller in Plan2 than in Plan1, and the percentage reduction was 6.72% and 6.19% (t = 5.14, 5.80, P < 0.05) at left and right side, respectively. Average dose and V 26 for both parotids were higher than those in Plan1, increasing by an average of 37.74%, 25.08% (Z = -6.03, -5.31, P < 0.05) for left parotid and 30.45%, 19.33% (Z = -5.43, -3.26, P < 0.05) for right parotid, respectively. Conclusions: The actual radiation dose to parotids was significantly increased during the radiation therapy for patients with head and neck cancer. There was a linear correlation between the decrease of distance between the COM of parotids and the midline of body and the percentage increase of parotids' radiation dose. No correlation between the reduction of parotids' volume and dose to parotids. In order to reduce the parotids' radiation dose, modification of treatment plan at the appropriate time is essential. (authors)

  4. Endoscope-guided interstitial intensity-modulated brachytherapy and intracavitary brachytherapy as boost radiation for primary early T stage nasopharyngeal carcinoma.

    Directory of Open Access Journals (Sweden)

    Xiang-Bo Wan

    Full Text Available BACKGROUND: Intracavitary brachytherapy (ICBT is usually applied as boost radiotherapy for superficial residual of nasopharyngeal carcinoma (NPC after primary extern-beam radiptherapy (ERT. Here, we evaluated the outcome of endoscope-guided interstitial intensity-modulated brachytherapy (IMBT boost radiation for deep-seated residual NPC. METHODOLOGY/PRINCIPAL FINDINGS: Two hundred and thirteen patients with residual NPC who were salvaged with brachytherapy boost radiation during 2005-2009 were analyzed retrospectively. Among these patients, 171 patients had superficial residual NPC (≤1 cm below the nasopharyngeal epithelium were treated with ICBT boost radiation, and interstitial IMBT boost radiation was delivered to 42 patients with deep-seated residual NPC (>1 cm below the nasopharyngeal epithelium. We found that IMBT boost subgroup had a higher ratio of T2b (81.0% VS 34.5%, P<0.001 and stage II (90.5% VS 61.4%, P = 0.001 than that of ICBT boost subgroup. The dosage of external-beam radiotherapy in the nasopharyngeal (63.0±3.8 VS 62.6±4.3 Gray (Gy, P = 0.67 and regional lymph nodes (55.8±5.0 VS 57.5±5.7 Gy, P = 0.11 was comparable in both groups. For brachytherapy, IMBT subgroup had a lower boost radiation dosage than ICBT subgroup (11.0±2.9 VS 14.8±3.2 Gy, P<0.01. Though the IMBT group had deeper residual tumors and received lower boost radiation dosages, both subgroups had the similar 5-year actuarial overall survival rate (IMBT VS ICBT group: 96.8% VS 93.6%, P = 0.87, progression-free survival rate (92.4% VS 86.5%, P = 0.41 and distant metastasis-free survival rate (94.9% VS 92.7%, P = 0.64. Moreover, IMBT boost radiation subgroup had a similar local (97.4% VS 94.4%, P = 0.57 and regional (95.0% VS 97.2%, P = 0.34 control to ICBT subgroup. The acute and late toxicities rates were comparable between the both subgroups. CONCLUSIONS/SIGNIFICANCE: IMBT boost radiation may be a promising therapeutic

  5. Consensus Guidelines and Contouring Atlas for Pelvic Node Delineation in Prostate and Pelvic Node Intensity Modulated Radiation Therapy.

    Science.gov (United States)

    Harris, Victoria A; Staffurth, John; Naismith, Olivia; Esmail, Alikhan; Gulliford, Sarah; Khoo, Vincent; Lewis, Rebecca; Littler, John; McNair, Helen; Sadoyze, Azmat; Scrase, Christopher; Sohaib, Aslam; Syndikus, Isabel; Zarkar, Anjali; Hall, Emma; Dearnaley, David

    2015-07-15

    The purpose of this study was to establish reproducible guidelines for delineating the clinical target volume (CTV) of the pelvic lymph nodes (LN) by combining the freehand Royal Marsden Hospital (RMH) and Radiation Therapy Oncology Group (RTOG) vascular expansion techniques. Seven patients with prostate cancer underwent standard planning computed tomography scanning. Four different CTVs (RMH, RTOG, modified RTOG, and Prostate and pelvIs Versus prOsTate Alone treatment for Locally advanced prostate cancer [PIVOTAL] trial) were created for each patient, and 6 different bowel expansion margins (BEM) were created to assess bowel avoidance by the CTV. The resulting CTVs were compared visually and by using Jaccard conformity indices. The volume of overlap between bowel and planning target volume (PTV) was measured to aid selection of an appropriate BEM to enable maximal LN yet minimal normal tissue coverage. In total, 84 nodal contours were evaluated. LN coverage was similar in all groups, with all of the vascular-expansion techniques (RTOG, modified RTOG, and PIVOTAL), resulting in larger CTVs than that of the RMH technique (mean volumes: 287.3 cm(3), 326.7 cm(3), 310.3 cm(3), and 256.7 cm(3), respectively). Mean volumes of bowel within the modified RTOG PTV were 19.5 cm(3) (with 0 mm BEM), 17.4 cm(3) (1-mm BEM), 10.8 cm(3) (2-mm BEM), 6.9 cm(3) (3-mm BEM), 5.0 cm(3) (4-mm BEM), and 1.4 cm(3) (5-mm BEM) in comparison with an overlap of 9.2 cm(3) seen using the RMH technique. Evaluation of conformity between LN-CTVs from each technique revealed similar volumes and coverage. Vascular expansion techniques result in larger LN-CTVs than the freehand RMH technique. Because the RMH technique is supported by phase 1 and 2 trial safety data, we proposed modifications to the RTOG technique, including the addition of a 3-mm BEM, which resulted in LN-CTV coverage similar to that of the RMH technique, with reduction in bowel and planning target volume overlap. On the basis of these

  6. Consensus Guidelines and Contouring Atlas for Pelvic Node Delineation in Prostate and Pelvic Node Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Victoria A. [Academic Urology Unit, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, London (United Kingdom); Staffurth, John [Institute of Cancer and Genetics, School of Medicine, Cardiff University, Cardiff, Wales (United Kingdom); Naismith, Olivia [Joint Department of Physics, Institute of Cancer Research, and Royal Marsden NHS Foundation Trust, London (United Kingdom); Esmail, Alikhan [Ipswich Hospital NHS Foundation Trust, Ipswich (United Kingdom); Gulliford, Sarah [Joint Department of Physics, Institute of Cancer Research, and Royal Marsden NHS Foundation Trust, London (United Kingdom); Khoo, Vincent [Department of Radiotherapy, The Royal Marsden NHS Foundation Trust, London (United Kingdom); Lewis, Rebecca [Clinical Trials and Statistics Unit, Institute of Cancer Research, London (United Kingdom); Littler, John [Clatterbridge Cancer Centre, Liverpool (United Kingdom); McNair, Helen [Department of Radiotherapy, The Royal Marsden NHS Foundation Trust, London (United Kingdom); Sadoyze, Azmat [Beatson West of Scotland Cancer Centre, Scotland, Glasgow (United Kingdom); Scrase, Christopher [Ipswich Hospital NHS Foundation Trust, Ipswich (United Kingdom); Sohaib, Aslam [Department of Radiology, The Royal Marsden NHS Foundation Trust, London (United Kingdom); Syndikus, Isabel [Clatterbridge Cancer Centre, Liverpool (United Kingdom); Zarkar, Anjali [University Hospitals Birmingham NHS Foundation Trust, Birmingham (United Kingdom); Hall, Emma [Clinical Trials and Statistics Unit, Institute of Cancer Research, London (United Kingdom); Dearnaley, David, E-mail: David.Dearnaley@icr.ac.uk [Academic Urology Unit, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, London (United Kingdom)

    2015-07-15

    Purpose: The purpose of this study was to establish reproducible guidelines for delineating the clinical target volume (CTV) of the pelvic lymph nodes (LN) by combining the freehand Royal Marsden Hospital (RMH) and Radiation Therapy Oncology Group (RTOG) vascular expansion techniques. Methods and Materials: Seven patients with prostate cancer underwent standard planning computed tomography scanning. Four different CTVs (RMH, RTOG, modified RTOG, and Prostate and pelvIs Versus prOsTate Alone treatment for Locally advanced prostate cancer [PIVOTAL] trial) were created for each patient, and 6 different bowel expansion margins (BEM) were created to assess bowel avoidance by the CTV. The resulting CTVs were compared visually and by using Jaccard conformity indices. The volume of overlap between bowel and planning target volume (PTV) was measured to aid selection of an appropriate BEM to enable maximal LN yet minimal normal tissue coverage. Results: In total, 84 nodal contours were evaluated. LN coverage was similar in all groups, with all of the vascular-expansion techniques (RTOG, modified RTOG, and PIVOTAL), resulting in larger CTVs than that of the RMH technique (mean volumes: 287.3 cm{sup 3}, 326.7 cm{sup 3}, 310.3 cm{sup 3}, and 256.7 cm{sup 3}, respectively). Mean volumes of bowel within the modified RTOG PTV were 19.5 cm{sup 3} (with 0 mm BEM), 17.4 cm{sup 3} (1-mm BEM), 10.8 cm{sup 3} (2-mm BEM), 6.9 cm{sup 3} (3-mm BEM), 5.0 cm{sup 3} (4-mm BEM), and 1.4 cm{sup 3} (5-mm BEM) in comparison with an overlap of 9.2 cm{sup 3} seen using the RMH technique. Evaluation of conformity between LN-CTVs from each technique revealed similar volumes and coverage. Conclusions: Vascular expansion techniques result in larger LN-CTVs than the freehand RMH technique. Because the RMH technique is supported by phase 1 and 2 trial safety data, we proposed modifications to the RTOG technique, including the addition of a 3-mm BEM, which resulted in LN-CTV coverage similar

  7. Clinical phase I/II trial to investigate neoadjuvant intensity-modulated short term radiation therapy (5 × 5 gy) and intraoperative radiation therapy (15 gy) in patients with primarily resectable pancreatic cancer - NEOPANC

    International Nuclear Information System (INIS)

    Roeder, Falk; Debus, Juergen; Huber, Peter E; Werner, Jens; Timke, Carmen; Saleh-Ebrahimi, Ladan; Schneider, Lutz; Hackert, Thilo; Hartwig, Werner; Kopp-Schneider, Annette; Hensley, Frank W; Buechler, Markus W

    2012-01-01

    The current standard treatment, at least in Europe, for patients with primarily resectable tumors, consists of surgery followed by adjuvant chemotherapy. But even in this prognostic favourable group, long term survival is disappointing because of high local and distant failure rates. Postoperative chemoradiation has shown improved local control and overalls survival compared to surgery alone but the value of additional radiation has been questioned in case of adjuvant chemotherapy. However, there remains a strong rationale for the addition of radiation therapy considering the high rates of microscopically incomplete resections after surgery. As postoperative administration of radiation therapy has some general disadvantages, neoadjuvant and intraoperative approaches theoretically offer benefits in terms of dose escalation, reduction of toxicity and patients comfort especially if hypofractionated regimens with highly conformal techniques like intensity-modulated radiation therapy are considered. The NEOPANC trial is a prospective, one armed, single center phase I/II study investigating a combination of neoadjuvant short course intensity-modulated radiation therapy (5 × 5 Gy) in combination with surgery and intraoperative radiation therapy (15 Gy), followed by adjuvant chemotherapy according to the german treatment guidelines, in patients with primarily resectable pancreatic cancer. The aim of accrual is 46 patients. The primary objectives of the NEOPANC trial are to evaluate the general feasibility of this approach and the local recurrence rate after one year. Secondary endpoints are progression-free survival, overall survival, acute and late toxicity, postoperative morbidity and mortality and quality of life. http://www.clinicaltrials.gov/ct2/show/NCT01372735

  8. Five-year Local Control in a Phase II Study of Hypofractionated Intensity Modulated Radiation Therapy With an Incorporated Boost for Early Stage Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Freedman, Gary M., E-mail: Gary.Freedman@uphs.upenn.edu [Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Anderson, Penny R. [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania (United States); Bleicher, Richard J. [Department of Surgical Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania (United States); Litwin, Samuel; Li Tianyu [Department of Biostatistics, Fox Chase Cancer Center, Philadelphia, Pennsylvania (United States); Swaby, Ramona F. [Department of Medical Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania (United States); Ma, Chang-Ming Charlie; Li Jinsheng [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania (United States); Sigurdson, Elin R. [Department of Surgical Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania (United States); Watkins-Bruner, Deborah [School of Nursing, Emory University, Atlanta, Georgia (United States); Morrow, Monica [Department of Surgical Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Goldstein, Lori J. [Department of Medical Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania (United States)

    2012-11-15

    Purpose: Conventional radiation fractionation of 1.8-2 Gy per day for early stage breast cancer requires daily treatment for 6-7 weeks. We report the 5-year results of a phase II study of intensity modulated radiation therapy (IMRT), hypofractionation, and incorporated boost that shortened treatment time to 4 weeks. Methods and Materials: The study design was phase II with a planned accrual of 75 patients. Eligibility included patients aged {>=}18 years, Tis-T2, stage 0-II, and breast conservation. Photon IMRT and an incorporated boost was used, and the whole breast received 2.25 Gy per fraction for a total of 45 Gy, and the tumor bed received 2.8 Gy per fraction for a total of 56 Gy in 20 treatments over 4 weeks. Patients were followed every 6 months for 5 years. Results: Seventy-five patients were treated from December 2003 to November 2005. The median follow-up was 69 months. Median age was 52 years (range, 31-81). Median tumor size was 1.4 cm (range, 0.1-3.5). Eighty percent of tumors were node negative; 93% of patients had negative margins, and 7% of patients had close (>0 and <2 mm) margins; 76% of cancers were invasive ductal type: 15% were ductal carcinoma in situ, 5% were lobular, and 4% were other histology types. Twenty-nine percent of patients 29% had grade 3 carcinoma, and 20% of patients had extensive in situ carcinoma; 11% of patients received chemotherapy, 36% received endocrine therapy, 33% received both, and 20% received neither. There were 3 instances of local recurrence for a 5-year actuarial rate of 2.7%. Conclusions: This 4-week course of hypofractionated radiation with incorporated boost was associated with excellent local control, comparable to historical results of 6-7 weeks of conventional whole-breast fractionation with sequential boost.

  9. Dosimetric Evaluation and Treatment Outcome of Intensity Modulated Radiation Therapy After Doxorubicin-Based Chemotherapy for Primary Mediastinal Large B-Cell Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Li-Ming [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences (CAMS) and Peking Union Medical College (PUMC), Beijing (China); Li, Ye-Xiong, E-mail: yexiong3@yahoo.com.cn [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences (CAMS) and Peking Union Medical College (PUMC), Beijing (China); Fang, Hui; Jin, Jing; Wang, Wei-Hu; Wang, Shu-Lian; Liu, Yue-Ping; Song, Yong-Wen; Liu, Qing-Feng; Chen, Bo; Qi, Shu-Nan; Ren, Hua; Dai, Jian-Rong [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences (CAMS) and Peking Union Medical College (PUMC), Beijing (China)

    2013-04-01

    Purpose: The value of intensity-modulated radiation therapy (IMRT) after doxorubicin-based chemotherapy in primary mediastinal large B-cell lymphoma (PMBCL) is unknown. We assessed the dosimetric parameters, treatment outcomes, and toxicity of IMRT in PMBCL. Methods and Materials: Forty-one PMBCL patients underwent mediastinal IMRT after doxorubicin-based chemotherapy. Thirty-eight patients had stage I-II disease, and 3 patients had stage III-IV disease. Most patients presented with bulky mediastinal disease (65.9%) and local invasion (82.9%). The dose-volume histograms of the target volume and critical normal structures were evaluated. Results: The average planning target volume (PTV) mean dose was 39 Gy. Only 0.5% and 1.4% of the PTV received <90% and <95% of the prescribed dose, respectively, indicating excellent target coverage. The median mean lung dose and percentage lung volume receiving 20 Gy (V20) were 16.3 Gy and 30.6%. The 5-year overall survival (OS) and local control (LC) were 95.1% and 89.8%. After chemotherapy, consolidation radiation therapy in patients with complete/partial response resulted in significantly better survival than salvage radiation therapy in patients with stable/progressive disease (3-year OS 100% vs 75%; 3-year LC 96.6% vs 62.5%). No grade 4 or 5 acute or late toxicities occurred. Conclusions: Mediastinal IMRT after doxorubicin-based chemotherapy can be safely and efficiently delivered, and it provides favorable outcomes in PMBCL patients with a large target volume and high-risk features.

  10. Dosimetric Evaluation and Treatment Outcome of Intensity Modulated Radiation Therapy After Doxorubicin-Based Chemotherapy for Primary Mediastinal Large B-Cell Lymphoma

    International Nuclear Information System (INIS)

    Xu, Li-Ming; Li, Ye-Xiong; Fang, Hui; Jin, Jing; Wang, Wei-Hu; Wang, Shu-Lian; Liu, Yue-Ping; Song, Yong-Wen; Liu, Qing-Feng; Chen, Bo; Qi, Shu-Nan; Ren, Hua; Dai, Jian-Rong

    2013-01-01

    Purpose: The value of intensity-modulated radiation therapy (IMRT) after doxorubicin-based chemotherapy in primary mediastinal large B-cell lymphoma (PMBCL) is unknown. We assessed the dosimetric parameters, treatment outcomes, and toxicity of IMRT in PMBCL. Methods and Materials: Forty-one PMBCL patients underwent mediastinal IMRT after doxorubicin-based chemotherapy. Thirty-eight patients had stage I-II disease, and 3 patients had stage III-IV disease. Most patients presented with bulky mediastinal disease (65.9%) and local invasion (82.9%). The dose-volume histograms of the target volume and critical normal structures were evaluated. Results: The average planning target volume (PTV) mean dose was 39 Gy. Only 0.5% and 1.4% of the PTV received <90% and <95% of the prescribed dose, respectively, indicating excellent target coverage. The median mean lung dose and percentage lung volume receiving 20 Gy (V20) were 16.3 Gy and 30.6%. The 5-year overall survival (OS) and local control (LC) were 95.1% and 89.8%. After chemotherapy, consolidation radiation therapy in patients with complete/partial response resulted in significantly better survival than salvage radiation therapy in patients with stable/progressive disease (3-year OS 100% vs 75%; 3-year LC 96.6% vs 62.5%). No grade 4 or 5 acute or late toxicities occurred. Conclusions: Mediastinal IMRT after doxorubicin-based chemotherapy can be safely and efficiently delivered, and it provides favorable outcomes in PMBCL patients with a large target volume and high-risk features

  11. Integration of real-time internal electromagnetic position monitoring coupled with dynamic multileaf collimator tracking: an intensity-modulated radiation therapy feasibility study.

    Science.gov (United States)

    Smith, Ryan L; Sawant, Amit; Santanam, Lakshmi; Venkat, Raghu B; Newell, Laurence J; Cho, Byung-Chul; Poulsen, Per; Catell, Herbert; Keall, Paul J; Parikh, Parag J

    2009-07-01

    Continuous tumor position measurement coupled with a tumor tracking system would result in a highly accurate radiation therapy system. Previous internal position monitoring systems have been limited by fluoroscopic radiation dose and low delivery efficiency. We aimed to incorporate a continuous, electromagnetic, three-dimensional position tracking system (Calypso 4D Localization System) with a dynamic multileaf collimator (DMLC)-based dose delivery system. A research version of the Calypso System provided real-time position of three Beacon transponders. These real-time three-dimensional positions were sent to research MLC controller with a motion-tracking algorithm that changed the planned leaf sequence. Electromagnetic transponders were embedded in a solid water film phantom that moved with patient lung trajectories while being irradiated with two different plans: a step-and-shoot intensity-modulated radiation therapy (S-IMRT) field and a dynamic IMRT (D-IMRT) field. Dosimetric results were recorded under three conditions: no intervention, DMLC tracking, and a spatial gating system. Dosimetric accuracy was comparable for gating and DMLC tracking. Failure rates for gating/DMLC tracking are as follows: +/-3 cGy 10.9/ 7.5% for S-IMRT, 3.3/7.2% for D-IMRT; gamma (3mm/3%) 0.2/1.2% for S-IMRT, 0.2/0.2% for D-IMRT. DMLC tracking proved to be as efficient as standard delivery, with a two- to fivefold efficiency increase over gating. Real-time target position information was successfully integrated into a DMLC effector system to modify dose delivery. Experimental results show both comparable dosimetric accuracy as well as improved efficiency compared with spatial gating.

  12. Correlation of Osteoradionecrosis and Dental Events With Dosimetric Parameters in Intensity-Modulated Radiation Therapy for Head-and-Neck Cancer

    International Nuclear Information System (INIS)

    Gomez, Daniel R.; Estilo, Cherry L.; Wolden, Suzanne L.; Zelefsky, Michael J.; Kraus, Dennis H.; Wong, Richard J.; Shaha, Ashok R.; Shah, Jatin P.; Mechalakos, James G.; Lee, Nancy Y.

    2011-01-01

    Purpose: Osteoradionecrosis (ORN) is a known complication of radiation therapy to the head and neck. However, the incidence of this complication with intensity-modulated radiation therapy (IMRT) and dental sequelae with this technique have not been fully elucidated. Methods and Materials: From December 2000 to July 2007, 168 patients from our institution have been previously reported for IMRT of the oral cavity, nasopharynx, larynx/hypopharynx, sinus, and oropharynx. All patients underwent pretreatment dental evaluation, including panoramic radiographs, an aggressive fluoride regimen, and a mouthguard when indicated. The median maximum mandibular dose was 6,798 cGy, and the median mean mandibular dose was 3,845 cGy. Patient visits were retrospectively reviewed for the incidence of ORN, and dental records were reviewed for the development of dental events. Univariate analysis was then used to assess the effect of mandibular and parotid gland dosimetric parameters on dental endpoints. Results: With a median clinic follow-up of 37.4 months (range, 0.8–89.6 months), 2 patients, both with oral cavity primaries, experienced ORN. Neither patient had preradiation dental extractions. The maximum mandibular dose and mean mandibular dose of the 2 patients were 7,183 and 6,828 cGy and 5812 and 5335 cGy, respectively. In all, 17% of the patients (n = 29) experienced a dental event. A mean parotid dose of >26 Gy was predictive of a subsequent dental caries, whereas a maximum mandibular dose >70 Gy and a mean mandibular dose >40 Gy were correlated with dental extractions after IMRT. Conclusions: ORN is rare after head-and-neck IMRT, but is more common with oral cavity primaries. Our results suggest different mechanisms for radiation-induced caries versus extractions.

  13. Correlation of Osteoradionecrosis and Dental Events With Dosimetric Parameters in Intensity-Modulated Radiation Therapy for Head-and-Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, Daniel R., E-mail: dgomez@mdanderson.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Estilo, Cherry L. [Dental Service, Department of Surgery, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Wolden, Suzanne L.; Zelefsky, Michael J. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Kraus, Dennis H.; Wong, Richard J.; Shaha, Ashok R.; Shah, Jatin P. [Department of Head and Neck Surgery, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Mechalakos, James G.; Lee, Nancy Y. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2011-11-15

    Purpose: Osteoradionecrosis (ORN) is a known complication of radiation therapy to the head and neck. However, the incidence of this complication with intensity-modulated radiation therapy (IMRT) and dental sequelae with this technique have not been fully elucidated. Methods and Materials: From December 2000 to July 2007, 168 patients from our institution have been previously reported for IMRT of the oral cavity, nasopharynx, larynx/hypopharynx, sinus, and oropharynx. All patients underwent pretreatment dental evaluation, including panoramic radiographs, an aggressive fluoride regimen, and a mouthguard when indicated. The median maximum mandibular dose was 6,798 cGy, and the median mean mandibular dose was 3,845 cGy. Patient visits were retrospectively reviewed for the incidence of ORN, and dental records were reviewed for the development of dental events. Univariate analysis was then used to assess the effect of mandibular and parotid gland dosimetric parameters on dental endpoints. Results: With a median clinic follow-up of 37.4 months (range, 0.8-89.6 months), 2 patients, both with oral cavity primaries, experienced ORN. Neither patient had preradiation dental extractions. The maximum mandibular dose and mean mandibular dose of the 2 patients were 7,183 and 6,828 cGy and 5812 and 5335 cGy, respectively. In all, 17% of the patients (n = 29) experienced a dental event. A mean parotid dose of >26 Gy was predictive of a subsequent dental caries, whereas a maximum mandibular dose >70 Gy and a mean mandibular dose >40 Gy were correlated with dental extractions after IMRT. Conclusions: ORN is rare after head-and-neck IMRT, but is more common with oral cavity primaries. Our results suggest different mechanisms for radiation-induced caries versus extractions.

  14. Normal Tissue Complication Probability Analysis of Acute Gastrointestinal Toxicity in Cervical Cancer Patients Undergoing Intensity Modulated Radiation Therapy and Concurrent Cisplatin

    International Nuclear Information System (INIS)

    Simpson, Daniel R.; Song, William Y.; Moiseenko, Vitali; Rose, Brent S.; Yashar, Catheryn M.; Mundt, Arno J.; Mell, Loren K.

    2012-01-01

    Purpose: To test the hypothesis that increased bowel radiation dose is associated with acute gastrointestinal (GI) toxicity in cervical cancer patients undergoing concurrent chemotherapy and intensity-modulated radiation therapy (IMRT), using a previously derived normal tissue complication probability (NTCP) model. Methods: Fifty patients with Stage I–III cervical cancer undergoing IMRT and concurrent weekly cisplatin were analyzed. Acute GI toxicity was graded using the Radiation Therapy Oncology Group scale, excluding upper GI events. A logistic model was used to test correlations between acute GI toxicity and bowel dosimetric parameters. The primary objective was to test the association between Grade ≥2 GI toxicity and the volume of bowel receiving ≥45 Gy (V 45 ) using the logistic model. Results: Twenty-three patients (46%) had Grade ≥2 GI toxicity. The mean (SD) V 45 was 143 mL (99). The mean V 45 values for patients with and without Grade ≥2 GI toxicity were 176 vs. 115 mL, respectively. Twenty patients (40%) had V 45 >150 mL. The proportion of patients with Grade ≥2 GI toxicity with and without V 45 >150 mL was 65% vs. 33% (p = 0.03). Logistic model parameter estimates V50 and γ were 161 mL (95% confidence interval [CI] 60–399) and 0.31 (95% CI 0.04–0.63), respectively. On multivariable logistic regression, increased V 45 was associated with an increased odds of Grade ≥2 GI toxicity (odds ratio 2.19 per 100 mL, 95% CI 1.04–4.63, p = 0.04). Conclusions: Our results support the hypothesis that increasing bowel V 45 is correlated with increased GI toxicity in cervical cancer patients undergoing IMRT and concurrent cisplatin. Reducing bowel V 45 could reduce the risk of Grade ≥2 GI toxicity by approximately 50% per 100 mL of bowel spared.

  15. Dosimetric benefits of placing dose constraints on the brachial plexus in patients with nasopharyngeal carcinoma receiving intensity-modulated radiation therapy: a comparative study.

    Science.gov (United States)

    Jiang, Hailan; Lu, Heming; Yuan, Hong; Huang, Huixian; Wei, Yinglin; Zhang, Yanxian; Liu, Xu

    2015-01-01

    This study aimed to evaluate whether placing dose constraints on the brachial plexus (BP) could provide dosimetric benefits in patients with nasopharyngeal carcinoma (NPC) undergoing intensity-modulated radiation therapy (IMRT). Planning CT images for 30 patients with NPC treated with definitive IMRT were retrospectively reviewed. Target volumes, the BP and other critical structures were delineated; two separate IMRT plans were designed for each patient: one set no restrictions for the BP; the other considered the BP as a critical structure for which a maximum dose limit of ≤66 Gy was set. No significant differences between the two plans were observed in the conformity index, homogeneity index, maximum dose to the planning target volumes (PTVs), minimum dose to the PTVs, percentages of the volume of the PTVnx and PTVnd receiving more than 110% of the prescribed dose, or percentages of the volume of the PTVs receiving 95% and > 93% of the prescribed dose. Dose constraints significantly reduced the maximum dose, mean dose, V45, V50, V54, V60, V66 and V70 to the BP. Dose constraints significantly reduced the maximum dose to the BP, V45, V60 and V66 in both N0-1 and N2-3 disease; however, the magnitude of the dosimetric gain for each parameter between N0-1 and N2-3 disease was not significantly different, except for the V60 and V66. In conclusion, placing dose constraints on the BP can significantly decrease the irradiated volume and dose, without compromising adequate dose delivery to the target volume. © The Author 2014. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  16. The effect of uterine motion and uterine margins on target and normal tissue doses in intensity modulated radiation therapy of cervical cancer

    Science.gov (United States)

    Gordon, J. J.; Weiss, E.; Abayomi, O. K.; Siebers, J. V.; Dogan, N.

    2011-05-01

    In intensity modulated radiation therapy (IMRT) of cervical cancer, uterine motion can be larger than cervix motion, requiring a larger clinical target volume to planning target volume (CTV-to-PTV) margin around the uterine fundus. This work simulates different motion models and margins to estimate the dosimetric consequences. A virtual study used image sets from ten patients. Plans were created with uniform margins of 1 cm (PTVA) and 2.4 cm (PTVC), and a margin tapering from 2.4 cm at the fundus to 1 cm at the cervix (PTVB). Three inter-fraction motion models (MM) were simulated. In MM1, all structures moved with normally distributed rigid body translations. In MM2, CTV motion was progressively magnified as one moved superiorly from the cervix to the fundus. In MM3, both CTV and normal tissue motion were magnified as in MM2, modeling the scenario where normal tissues move into the void left by the mobile uterus. Plans were evaluated using static and percentile DVHs. For a conventional margin (PTVA), quasi-realistic uterine motion (MM3) reduces fundus dose by about 5 Gy and increases normal tissue volumes receiving 30-50 Gy by ~5%. A tapered CTV-to-PTV margin can restore fundus and CTV doses, but will increase normal tissue volumes receiving 30-50 Gy by a further ~5%.

  17. Dosimetric and Clinical Outcomes With Intensity Modulated Radiation Therapy After Chemotherapy for Patients With Early-Stage Diffuse Large B-cell Lymphoma of Waldeyer Ring

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yong-Gang; Qi, Shu-Nan; Wang, Shu-Lian; Liu, Yue-Ping; Wang, Wei-Hu; Jin, Jing; Song, Yong-Wen; Ren, Hua; Fang, Hui [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); He, Xiao-Hui; Dong, Mei [Department of Medical Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); Chen, Bo; Lu, Ning-Ning; Li, Ning; Tang, Yuan; Tang, Yu; Dai, Jian-Rong [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); Li, Ye-Xiong, E-mail: yexiong12@163.com [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China)

    2016-10-01

    Purpose: To assess the dosimetric benefit, prognosis, and toxicity of intensity modulated radiation therapy (IMRT) for early-stage, diffuse large B-cell lymphoma of Waldeyer ring (WR-DLBCL). Methods and Materials: Sixty-one patients with early-stage WR-DLBCL who received chemotherapy followed by IMRT were retrospectively reviewed. Dosimetric parameters for the target volume and critical normal structures were evaluated, and survival was calculated. Linear regression analysis was used to assess the effect of the mean dose (D{sub mean}) to the parotid glands on xerostomia. Results: The median conformity index and homogeneity index of the planning target volume (PTV) were 0.83 and 0.90, respectively, demonstrating very good coverage of the target volume. The mean dose to the parotid glands was 24.9 Gy. The 5-year overall survival (OS), progression-free survival (PFS), and locoregional control (LRC) were 94.7%, 93.1%, and 98.3%, respectively. Early and late toxicities were mild, and no patient experienced late grade ≥3 toxicities. The D{sub mean} to the parotid glands had a linear correlation with late grade ≥2 xerostomia. Conclusions: IMRT after chemotherapy can provide excellent dose conformity and achieve favorable survival and LRC with mild toxicities in patients with early-stage WR-DLBCL. Dose constraints for the parotid glands should be limited to <24 Gy for early-stage WR-DLBCL.

  18. Dose non-linearity of the dosimetry system and possible monitor unit errors on medical linear accelerators used in conventional and intensity-modulated radiation therapy

    Directory of Open Access Journals (Sweden)

    Muhammad Wazir

    2012-01-01

    Full Text Available The purpose of this work is to study dose non-linearity in medical linear accelerators used in conventional radiotherapy and intensity-modulated radiation therapy. Open fields, as well as the enhanced dynamic wedge ones, were used to collect data for 6 MV and 15 MV photon beams obtained from the VARIAN linear accelerator. Beam stability was checked and confirmed for different dose rates, energies, and application of enhanced dynamic wedge by calculating the charge per monitor unit. Monitor unit error was calculated by the two-exposure method for open and enhanced dynamic wedge beams of 6 MV and 15 MV photons. A significant monitor unit error with maximum values of ±2.05931 monitor unit and ±2.44787 monitor unit for open and enhanced dynamic wedge beams, respectively, both energy and dose rate dependent, was observed both in the open photon beam and enhanced dynamic wedge fields. However, it exhibited certain irregular patterns at enhanced dynamic wedge angles. Dose monitor unit error exists only because of the overshoot phenomena and electronic delay in dose coincident and integrated circuits with a dependency on the dose rate and photon energy. Monitor unit errors are independent of the application of enhanced dynamic wedge. The existence of monitor unit error demands that the dose non-linearity of the linear accelerator dosimetry system be periodically tested, so as to avoid significant dosimetric errors.

  19. Dosimetric comparison of vaginal vault ovoid brachytherapy versus intensity-modulated radiation therapy plans in postoperative patients of cervical carcinoma following whole pelvic radiotherapy

    Directory of Open Access Journals (Sweden)

    Divya Khosla

    2014-01-01

    Full Text Available Introduction: Dosimetric study to compare high dose rate (HDR vaginal vault ovoid brachytherapy plan versus intensity-modulated radiation therapy (IMRT boost plan for doses delivered to target volume and organs at risk (OAR in postoperative patients of cervical carcinoma following whole pelvic radiotherapy (WPRT. Materials and Methods: Fifteen postoperative patients of cervical carcinoma suitable for vaginal ovoid brachytherapy following WPRT of 46 Gy/23 fractions/4.5 weeks were included. All were treated with brachytherapy (two sessions of 8.5 Gy each. The equivalent dose for IMRT was calculated by computing biologically effective dose of brachytherapy by linear quadratic model. Dose of brachytherapy (two sessions of 8.5 Gy was equivalent to IMRT dose of 26 Gy/13 fractions. Doses to target volume and OAR were compared between HDR and IMRT plans. Results: Target volume was well covered with both HDR and IMRT plans, but dose with brachytherapy was much higher (P < 0.05. Mean doses, doses to 0.1, 1, 2, and 5cc, 1/3 rd , 1/2, and 2/3 rd volume of bladder and rectum were significantly lower with HDR plans. Conclusion: In postoperative patients of cervical carcinoma, HDR brachytherapy following WPRT appears to be better than IMRT for tumor coverage and reducing dose to critical organs.

  20. SU-E-P-58: Dosimetric Study of Conventional Intensity-Modulated Radiotherapy and Knowledge-Based Radiation Therapy for Postoperation of Cervix Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ma, C; Yin, Y [Shandong Tumor Hospital, Jinan, Shandong Provice (China)

    2015-06-15

    Purpose: To compare the dosimetric difference of the target volume and organs at risk(OARs) between conventional intensity-modulated radiotherapy(C-IMRT) and knowledge-based radiation therapy (KBRT) plans for cervix cancer. Methods: 39 patients with cervical cancer after surgery were randomly selected, 20 patient plans were used to create the model, the other 19 cases used for comparative evaluation. All plans were designed in Eclipse system. The prescription dose was 30.6Gy, 17 fractions, OARs dose satisfied to the clinical requirement. A paired t test was used to evaluate the differences of dose-volume histograms (DVH). Results: Comparaed to C-IMRT plan, the KBRT plan target can achieve the similar target dose coverage, D98,D95,D2,HI and CI had no difference (P≥0.05). The dose of rectum, bladder and femoral heads had no significant differences(P≥0.05). The time was used to design treatment plan was significant reduced. Conclusion: This study shows that postoperative radiotherapy of cervical KBRT plans can achieve the similar target and OARs dose, but the shorter designing time.

  1. Dosimetric distribution to tooth-bearing areas in intensity-modulated radiation therapy for head and neck cancer: a pilot study.

    Science.gov (United States)

    Bak, Sun-Yung; Qi, X Sharon; Kelly, James A; Alexander, Sherri; Chung, Yunro; Gyurdzhyan, Samvel; Patton, Lauren L; Lee, Steve P

    2016-01-01

    Dosimetric distribution of intensity-modulated radiotherapy (IMRT) to tooth-bearing areas for common head and neck (H&N) cancer sites were analyzed to facilitate minimization of osteoradionecrosis (ORN) risk through preradiation dental treatment planning. Fifty-four patients received IMRT with prescribed doses ranging from 6000 centigrays (cGy) (adjuvant) to 6930 cGy (primary) to treat base of tongue (BOT), tonsil, larynx, nasopharynx, and hypopharynx cancers. The average maximal radiation dose delivered was recorded in tooth-bearing areas (anteriors, premolars, and first, second, and third molars) of the maxilla and mandible. All tooth-bearing areas in laryngeal cancer cases received less than 2500 cGy. Maxillary and mandibular molar regions for BOT, tonsil, and hypopharynx cancers received 5000 cGy or higher. In nasopharynx cancers, maxillary teeth received higher doses than mandibular teeth. Among 5 H&N subsites, mandibular molar regions for BOT, tonsil, and hypopharynx cancers received higher IMRT doses on average, posing the greatest ORN risk. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Different setup errors assessed by weekly cone-beam computed tomography on different registration in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy.

    Science.gov (United States)

    Su, Jiqing; Chen, Wen; Yang, Huiyun; Hong, Jidong; Zhang, Zijian; Yang, Guangzheng; Li, Li; Wei, Rui

    2015-01-01

    The study aimed to investigate the difference of setup errors on different registration in the treatment of nasopharyngeal carcinoma based on weekly cone-beam computed tomography (CBCT). Thirty nasopharyngeal cancer patients scheduled to undergo intensity-modulated radiotherapy (IMRT) were prospectively enrolled in the study. Each patient had a weekly CBCT before radiation therapy. In the entire study, 201 CBCT scans were obtained. The scans were registered to the planning CT to determine the difference of setup errors on different registration sites. Different registration sites were represented by bony landmarks. Nasal septum and pterygoid process represent head, cervical vertebrae 1-3 represent upper neck, and cervical vertebrae 4-6 represent lower neck. Patient positioning errors were recorded in the right-left (RL), superior-inferior (SI), and anterior-posterior (AP) directions over the course of radiotherapy. Planning target volume margins were calculated from the systematic and random errors. In this study, we can make a conclusion that there are setup errors in RL, SI, and AP directions of nasopharyngeal carcinoma patients undergoing IMRT. In addition, the head and neck setup error has the difference, with statistical significance, while patient setup error of neck is greater than that of head during the course of radiotherapy. In our institution, we recommend a planning target volume margin of 3.0 mm in RL direction, 1.3 mm in SI direction, and 2.6 mm in AP direction for nasopharyngeal cancer patients undergoing IMRT with weekly CBCT scans.

  3. A dosimetric analysis of intensity-modulated radiation therapy (IMRT) as an alternative to adjuvant high-dose-rate (HDR) brachytherapy in early endometrial cancer patients.

    Science.gov (United States)

    Aydogan, Bulent; Mundt, Arno J; Smith, Brett D; Mell, Loren K; Wang, Steve; Sutton, Harold; Roeske, John C

    2006-05-01

    To evaluate the role of intensity-modulated radiation treatment (IMRT) as an alternative to high-dose-rate (HDR) brachytherapy in the treatment of the vagina in postoperative early endometrial cancer patients after surgery. Planning computed tomography (CT) scans of 10 patients previously treated with HDR were used in this study. In all cases, a dose of 700 cGy/fraction was prescribed at a distance of 0.5 cm from the cylinder surface. The same CT scans were then used in IMRT planning. In this paradigm, the vaginal cylinder represents a component of a hypothetical immobilization system that would be indexed to the linac treatment table. Our study showed that IMRT provided relatively lower rectal doses than HDR when treatment was prescribed at a distance of 0.5 cm away from the cylinder surface. Maximum rectal doses were lower with IMRT compared with HDR (average: 89.0% vs. 142.6%, respectively, p in IMRT plans compared with HDR plans with treatment prescribed either to the surface (average: 14.8% vs. 21.4%, respectively, p in conjunction with a suitable immobilization system, IMRT may provide an alternative to HDR brachytherapy in women with early endometrial cancer after hysterectomy. However, more studies are needed to evaluate the clinical merit of the IMRT in these patients.

  4. Tomotherapy: IMRT and tomographic verification

    International Nuclear Information System (INIS)

    Mackie, T.R.

    2000-01-01

    Full text: External beam radiation therapy delivery began around the turn of the century with the use of one or a few kilovoltage beams directed to the presumed site of the tumor. Often the treatment lasted until erythema dose was reached. Delivering the beams rotationally allowed the dose to be focused on the tumor and the skin to be spared. With the advent of megavoltage radiation therapy in the 1950's, using Co-60 teletherapy and betatrons, the treatment could once again be delivered from only a few beam directions and the dose to the skin would be kept below tolerance. Fields were shaped by lead blocks and later by custom-made blocks fabricated from low-melting temperature heavy metal. Linear accelerators did not fundamentally change the way in which radiation was delivered. It is likely that this delivery paradigm would not have changed had it not been for the advent of computers. Brahme and Cormack showed in the late 1980's that highly conformal treatments could be delivered with non-uniform intensity beams. At that time the only way in which the intensity modulated beams could be delivered was using custom-milled compensators. Fabricating and using compensators for multiple fields is time-consuming and labor-intensive. Serial tomotherapy was the first successful delivery method for IMRT and went back to the earlier practice of rotation therapy. The NOMOS Peacock system uses a binary (on-off) multileaf collimator (MLC) system to modulate a fan beam of radiation. It uses an optimization system to determine when leaves should be opened and closed. The system delivers two beam slices at once and the couch is indexed to the next slices by precisely translating the couch. This approach was first used in 1994 and to-date has treated several thousand patients. Prior to the advent of IMRT, accelerator vendors introduced the multileaf collimator (MLC) to provide field shaping without the need to fabricate custom blocking. Most new linear accelerator purchases today

  5. The Impact of Intensity Modulated Radiation Therapy on Hospitalization Outcomes in the SEER-Medicare Population With Anal Squamous Cell Carcinoma

    International Nuclear Information System (INIS)

    Pollom, Erqi L.; Wang, Guanying; Harris, Jeremy P.; Koong, Albert C.; Bendavid, Eran; Bhattacharya, Jay; Chang, Daniel T.

    2017-01-01

    Purpose: We examined the impact of intensity modulated radiation therapy (IMRT) on hospitalization rates in the Surveillance, Epidemiology, and End Results (SEER)–Medicare population with anal squamous cell carcinoma (SCC). Methods and Materials: We performed a retrospective cohort study using the SEER-Medicare database. We identified patients with nonmetastatic anal SCC diagnosed between 2001 and 2011 and treated with chemoradiation therapy. We assessed the relation between IMRT and first hospitalization by use of a multivariate competing-risk model, as well as instrumental variable analysis, using provider IMRT affinity as our instrument. Results: Of the 1165 patients included in our study, 458 (39%) received IMRT. IMRT use increased over time and was associated more with regional and provider characteristics than with patient characteristics. The 3- and 6-month cumulative incidences of first hospitalization were 41.9% (95% confidence interval [CI], 37.3%-46.4%) and 47.6% (95% CI, 43.0%-52.2%), respectively, for the IMRT cohort and 46.7% (95% CI, 43.0%-50.4%) and 52.1% (95% CI, 48.4%-55.7%), respectively, for the non-IMRT cohort. IMRT was associated with a decreased hazard of first hospitalization compared with 3-dimensional radiation techniques (hazard ratio, 0.70; 95% CI, 0.58-0.84; P=.0002). Instrumental variable analysis suggested an even greater reduction in hospitalizations with IMRT after controlling for unmeasured confounders. There was a trend toward improved overall survival with IMRT, with an adjusted hazard ratio of 0.77 (95% CI, 0.59-1.00; P=.05). Conclusions: The use of IMRT is associated with reduced hospitalizations in elderly patients with anal SCC. Further work is warranted to understand the long-term health and cost impact of IMRT, particularly for patient subgroups most at risk of toxicity and hospitalization.

  6. Prospective study of sequential volumetric changes of parotid gland in early oropharyngeal carcinoma patients treated by intensity-modulated radiation therapy: An institutional experience

    Directory of Open Access Journals (Sweden)

    Pooja Nandwani Patel

    2018-01-01

    Full Text Available Aims and Objectives: During course of radiation therapy, anatomical variations occur risking overdose of parotid gland. We tried to quantify volume of parotid gland and mean dose to parotid gland after every 10 fractions (#. Materials and Methods: We conducted the prospective study from July 2016 to May 2017 in 25 patients of early-stage oropharyngeal carcinoma. Patients had Karnofsy Performance Score of 80–100, median age was 54 years, and 18 patients were males. Patients were planned with intensity-modulated radiation therapy planning with dose as 66 Gy/30# to planning target volume (PTV including primary and 54 Gy/30# to PTV-nodal including elective neck irradiation. After each 10#, replanning was done, and variations in parotid volume were studied including Dmean(mean dose to parotids and D50(the dose delivered to 50% of volume. Other tumor characteristic like PTV of primary was also assessed and minimum PTV volume covered by 95% isodose line was kept as 95%. Results: Average parotid volumes decreased by the mean value of 10% and 6% for the left and right parotids, respectively, and PTV of primary target decreased by mean of 13%. The difference in Dmeandoses to parotid glands was 32% and 42% and difference in D50dose was 30% and 35% on the left and right side, respectively. Conclusions: The parotid volumes differ considerably during adaptive planning done after every ten fractions. These differences in parotid volumes and doses received to parotid glands play a significant role in the risk of xerostomia observed during later follow-up.

  7. Outcomes of patients diagnosed with carcinoma metastatic to the neck from an unknown primary source and treated with intensity-modulated radiation therapy.

    Science.gov (United States)

    Kamal, Mona; Mohamed, Abdallah S R; Fuller, Clifton David; Sturgis, Erich M; Johnson, Faye M; Morrison, William H; Gunn, G Brandon; Hutcheson, Katherine A; Phan, Jack; Volpe, Stefania; Ng, Sweet Ping; Ferrarotto, Renata; Frank, Steven J; Skinner, Heath D; Rosenthal, David I; Garden, Adam S

    2018-01-16

    There are few published studies to guide the treatment of carcinoma metastatic to the neck from an unknown primary (CUP). In this regard, the objective of the current study was to share the authors' current experience treating patients with CUP using intensity-modulated radiation therapy (IMRT), which principally targeted both sides of the neck, the nasopharynx, and the oropharynx. This was a retrospective study in which an institutional database search was conducted to identify patients with CUP who received IMRT. Data analysis included frequency tabulation, survival analysis, and multivariable analysis. Two-hundred sixty patients met inclusion criteria. The most common lymph node category was N2b (54%). IMRT volumes included the entire pharyngolaryngeal mucosa in 78 patients, the nasopharynx and oropharynx in 167 patients, and treatment limited to the involved neck in 11 patients. Eighty-four patients underwent neck dissections. The 5-year overall survival, regional control, and distant metastases-free survival rates were 84%, 91%, and 94%, respectively. Over 40% of patients had gastrostomy tubes during therapy, and 7% patients were diagnosed with chronic radiation-associated dysphagia. Higher lymph node burden was associated with worse disease-related outcomes, and in subgroup analysis, patients with human papillomavirus-associated disease had better outcomes. No therapeutic modality was statistically associated with either disease-related outcomes or toxicity. Comprehensive IMRT with treatment to both sides of the neck and to the oropharyngeal and nasopharyngeal mucosa results in high rates of disease control and survival. The investigators were unable to demonstrate that treatment intensification with chemotherapy or surgery added benefit or excessive toxicity. Cancer 2018. © 2018 American Cancer Society. © 2018 American Cancer Society.

  8. Integrated skin flash planning technique for intensity-modulated radiation therapy for vulvar cancer prevents marginal misses and improves superficial dose coverage.

    Science.gov (United States)

    Dyer, Brandon A; Jenshus, Abriel; Mayadev, Jyoti S

    2018-02-28

    Radiation therapy (RT) plays a definitive role in locally advanced vulvar cancer, and in the adjuvant setting with high risk postoperative features after wide local excision. There is significant morbidity associated with traditional, large RT fields using 2D or 3D techniques, and the use of intensity-modulated radiation therapy (IMRT) in vulvar cancer is increasing. However, there remains a paucity of technical information regarding the prevention of a marginal miss during the treatment planning process. The use of an integrated skin flash (ISF) during RT planning can be used to account for anatomic variation, and intra- and interfraction motion seen during treatment. Herein we present the case of a patient with a T1aN0M0, Stage IA vulva cancer to illustrate the progressive vulvar swelling and lymph edema seen during treatment and retrospectively evaluate the dosimetric effects of using an ISF RT plan vs standard RT planning techniques. Standard planning techniques to treat vulvar cancer patients with IMRT do not sufficiently account for the change in patient anatomy and can lead to a marginal miss. ISF is an RT planning technique that can decrease the risk of a marginal miss and the technique is easily implemented during the planning stages of RT treatment. Furthermore, use of an ISF technique can improve vulvar clinical target volume coverage and plan homogeneity. Based on our experience, and this study, a 2-cm ISF is suggested to account for variations in daily clinical setup and changes in patient anatomy during treatment. Published by Elsevier Inc.

  9. Comparison of Planning Quality and Efficiency Between Conventional and Knowledge-based Algorithms in Nasopharyngeal Cancer Patients Using Intensity Modulated Radiation Therapy.

    Science.gov (United States)

    Chang, Amy T Y; Hung, Albert W M; Cheung, Fion W K; Lee, Michael C H; Chan, Oscar S H; Philips, Helen; Cheng, Yung-Tang; Ng, Wai-Tong

    2016-07-01

    Intensity modulated radiation therapy (IMRT) is widely used to achieve a highly conformal dose and improve treatment outcome. However, plan quality and planning time are institute and planner dependent, and no standardized tool exists to recognize an optimal plan. RapidPlan, a knowledge-based algorithm, can generate constraints to assist optimization and produce high-quality IMRT plans. This report evaluated the quality and efficiency of using RapidPlan in nasopharyngeal carcinoma (NPC) IMRT planning. RapidPlan was configured using 79 radical IMRT plans for NPC; 20 consecutive NPC patients indicated for radical radiation therapy between October 2014 and May 2015 were then recruited to assess its performance. The ability of RapidPlan to produce acceptable plans was evaluated. For plans that could not achieve clinical acceptance, manual touch-up was performed. The IMRT plans produced without RapidPlan (manual plans) and with RapidPlan (RP-2 plans, including those with manual touch-up) were compared in terms of dosimetric quality and planning efficiency. RapidPlan by itself could produce clinically acceptable plans for 9 of the 20 patients; manual touch-up increased the number of acceptable plans (RP-2 plans) to 19. The target dose coverage and conformity were very similar. No difference was found in the maximum dose to the brainstem and optic chiasm. RP-2 plans delivered a higher maximum dose to the spinal cord (46.4 Gy vs 43.9 Gy, P=.002) but a lower dose to the parotid (mean dose to right parotid, 37.3 Gy vs 45.4 Gy; left, 34.4 Gy vs 43.1 Gy; Pmanual plans (64 minutes vs 295 minutes, P<.001). This study shows that RapidPlan can significantly improve planning efficiency and produce quality IMRT plans for NPC patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Dose linearity and uniformity of a linear accelerator designed for implementation of multileaf collimation system-based intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Saw, Cheng B.; Li Sicong; Ayyangar, Komanduri M.; Yoe-Sein, Maung; Pillai, Susha; Enke, Charles A.; Celi, Juan C.

    2003-01-01

    The dose linearity and uniformity of a linear accelerator designed for multileaf collimation system- (MLC) based IMRT was studied as a part of commissioning and also in response to recently published data. The linear accelerator is equipped with a PRIMEVIEW, a graphical interface and a SIMTEC IM-MAXX, which is an enhanced autofield sequencer. The SIMTEC IM-MAXX sequencer permits the radiation beam to be 'ON' continuously while delivering intensity modulated radiation therapy subfields at a defined gantry angle. The dose delivery is inhibited when the electron beam in the linear accelerator is forced out of phase with the microwave power while the MLC configures the field shape of a subfield. This beam switching mechanism reduces the overhead time and hence shortens the patient treatment time. The dose linearity, reproducibility, and uniformity were assessed for this type of dose delivery mechanism. The subfields with monitor units ranged from 1 MU to 100 MU were delivered using 6 MV and 23 MV photon beams. The doses were computed and converted to dose per monitor unit. The dose linearity was found to vary within 2% for both 6 MV and 23 MV photon beam using high dose rate setting (300 MU/min) except below 2 MU. The dose uniformity was assessed by delivering 4 subfields to a Kodak X-OMAT TL film using identical low monitor units. The optical density was converted to dose and found to show small variation within 3%. Our results indicate that this linear accelerator with SIMTEC IM-MAXX sequencer has better dose linearity, reproducibility, and uniformity than had been reported

  11. Normal tissue complication probability modeling for cochlea constraints to avoid causing tinnitus after head-and-neck intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Lee, Tsair-Fwu; Yeh, Shyh-An; Chao, Pei-Ju; Chang, Liyun; Chiu, Chien-Liang; Ting, Hui-Min; Wang, Hung-Yu; Huang, Yu-Jie

    2015-01-01

    Radiation-induced tinnitus is a side effect of radiotherapy in the inner ear for cancers of the head and neck. Effective dose constraints for protecting the cochlea are under-reported. The aim of this study is to determine the cochlea dose limitation to avoid causing tinnitus after head-and-neck cancer (HNC) intensity-modulated radiation therapy (IMRT). In total 211 patients with HNC were included; the side effects of radiotherapy were investigated for 422 inner ears in the cohort. Forty-nine of the four hundred and twenty-two samples (11.6 %) developed grade 2+ tinnitus symptoms after IMRT, as diagnosed by a clinician. The Late Effects of Normal Tissues–Subjective, Objective, Management, Analytic (LENT-SOMA) criteria were used for tinnitus evaluation. The logistic and Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) models were used for the analyses. The NTCP-fitted parameters were TD 50 = 46.31 Gy (95 % CI, 41.46–52.50), γ 50 = 1.27 (95 % CI, 1.02–1.55), and TD 50 = 46.52 Gy (95 % CI, 41.91–53.43), m = 0.35 (95 % CI, 0.30–0.42) for the logistic and LKB models, respectively. The suggested guideline TD 20 for the tolerance dose to produce a 20 % complication rate within a specific period of time was TD 20 = 33.62 Gy (95 % CI, 30.15–38.27) (logistic) and TD 20 = 32.82 Gy (95 % CI, 29.58–37.69) (LKB). To maintain the incidence of grade 2+ tinnitus toxicity <20 % in IMRT, we suggest that the mean dose to the cochlea should be <32 Gy. However, models should not be extrapolated to other patient populations without further verification and should first be confirmed before clinical implementation

  12. The Impact of Intensity Modulated Radiation Therapy on Hospitalization Outcomes in the SEER-Medicare Population With Anal Squamous Cell Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Pollom, Erqi L., E-mail: erqiliu@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Wang, Guanying [Department of Health Research and Policy, Stanford University School of Medicine, Stanford, California (United States); Harris, Jeremy P.; Koong, Albert C. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Bendavid, Eran; Bhattacharya, Jay [Center for Health Policy–Center for Primary Care and Outcomes Research, Stanford University School of Medicine, Stanford, California (United States); Chang, Daniel T. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States)

    2017-05-01

    Purpose: We examined the impact of intensity modulated radiation therapy (IMRT) on hospitalization rates in the Surveillance, Epidemiology, and End Results (SEER)–Medicare population with anal squamous cell carcinoma (SCC). Methods and Materials: We performed a retrospective cohort study using the SEER-Medicare database. We identified patients with nonmetastatic anal SCC diagnosed between 2001 and 2011 and treated with chemoradiation therapy. We assessed the relation between IMRT and first hospitalization by use of a multivariate competing-risk model, as well as instrumental variable analysis, using provider IMRT affinity as our instrument. Results: Of the 1165 patients included in our study, 458 (39%) received IMRT. IMRT use increased over time and was associated more with regional and provider characteristics than with patient characteristics. The 3- and 6-month cumulative incidences of first hospitalization were 41.9% (95% confidence interval [CI], 37.3%-46.4%) and 47.6% (95% CI, 43.0%-52.2%), respectively, for the IMRT cohort and 46.7% (95% CI, 43.0%-50.4%) and 52.1% (95% CI, 48.4%-55.7%), respectively, for the non-IMRT cohort. IMRT was associated with a decreased hazard of first hospitalization compared with 3-dimensional radiation techniques (hazard ratio, 0.70; 95% CI, 0.58-0.84; P=.0002). Instrumental variable analysis suggested an even greater reduction in hospitalizations with IMRT after controlling for unmeasured confounders. There was a trend toward improved overall survival with IMRT, with an adjusted hazard ratio of 0.77 (95% CI, 0.59-1.00; P=.05). Conclusions: The use of IMRT is associated with reduced hospitalizations in elderly patients with anal SCC. Further work is warranted to understand the long-term health and cost impact of IMRT, particularly for patient subgroups most at risk of toxicity and hospitalization.

  13. Prospective Randomized Phase 2 Trial of Intensity Modulated Radiation Therapy With or Without Oncolytic Adenovirus-Mediated Cytotoxic Gene Therapy in Intermediate-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Freytag, Svend O., E-mail: sfreyta1@hfhs.org [Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan (United States); Stricker, Hans [Vattikuti Urology Institute, Henry Ford Health System, Detroit, Michigan (United States); Lu, Mei [Public Health Sciences, Henry Ford Health System, Detroit, Michigan (United States); Elshaikh, Mohamed; Aref, Ibrahim; Pradhan, Deepak; Levin, Kenneth; Kim, Jae Ho [Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan (United States); Peabody, James [Vattikuti Urology Institute, Henry Ford Health System, Detroit, Michigan (United States); Siddiqui, Farzan; Barton, Kenneth; Pegg, Jan; Zhang, Yingshu; Cheng, Jingfang [Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan (United States); Oja-Tebbe, Nancy; Bourgeois, Renee [Public Health Sciences, Henry Ford Health System, Detroit, Michigan (United States); Gupta, Nilesh; Lane, Zhaoli [Pathology, Henry Ford Health System, Detroit, Michigan (United States); Rodriguez, Ron [Urology, Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); DeWeese, Theodore [Department of Radiation Oncology, Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); and others

    2014-06-01

    Purpose: To assess the safety and efficacy of combining oncolytic adenovirus-mediated cytotoxic gene therapy (OAMCGT) with intensity modulated radiation therapy (IMRT) in intermediate-risk prostate cancer. Methods and Materials: Forty-four men with intermediate-risk prostate cancer were randomly assigned to receive either OAMCGT plus IMRT (arm 1; n=21) or IMRT only (arm 2; n=23). The primary phase 2 endpoint was acute (≤90 days) toxicity. Secondary endpoints included quality of life (QOL), prostate biopsy (12-core) positivity at 2 years, freedom from biochemical/clinical failure (FFF), freedom from metastases, and survival. Results: Men in arm 1 exhibited a greater incidence of low-grade influenza-like symptoms, transaminitis, neutropenia, and thrombocytopenia than men in arm 2. There were no significant differences in gastrointestinal or genitourinary events or QOL between the 2 arms. Two-year prostate biopsies were obtained from 37 men (84%). Thirty-three percent of men in arm 1 were biopsy-positive versus 58% in arm 2, representing a 42% relative reduction in biopsy positivity in the investigational arm (P=.13). There was a 60% relative reduction in biopsy positivity in the investigational arm in men with <50% positive biopsy cores at baseline (P=.07). To date, 1 patient in each arm exhibited biochemical failure (arm 1, 4.8%; arm 2, 4.3%). No patient developed hormone-refractory or metastatic disease, and none has died from prostate cancer. Conclusions: Combining OAMCGT with IMRT does not exacerbate the most common side effects of prostate radiation therapy and suggests a clinically meaningful reduction in positive biopsy results at 2 years in men with intermediate-risk prostate cancer.

  14. [Personnel requirements of medical radiation physics in radiotherapy in comparison to the current guidelines "radiation protection in medicine" : Special consideration of intensity-modulated radiation therapy].

    Science.gov (United States)

    Leetz, H-K; Eipper, H H; Gfirtner, H; Schneider, P; Welker, K

    2014-08-01

    In 1994 and 1998 reports on staffing levels in medical radiation physics for radiation therapy were published by the "Deutsche Gesellschaft für Medizinische Physik" (DGMP, German Society for Medical Physics). Because of the technical and methodological progress, changes in recommended qualifications of staff and new governmental regulations, it was necessary to establish new staffing levels. The data were derived from a new survey in clinics. Some of the previously established results from the old reports were adapted to the new conditions by conversion.The staffing requirements were normalized to main components as in the earlier reports resulting in a simple method for calculation of staffing levels. The results were compared with the requirements in the "Richtlinie Strahlenschutz in der Medizin" (guidelines on radiation protection in medicine) and showed satisfactory agreement.

  15. Risk of Late Toxicity in Men Receiving Dose-Escalated Hypofractionated Intensity Modulated Prostate Radiation Therapy: Results From a Randomized Trial

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, Karen E., E-mail: khoffman1@mdanderson.org; Voong, K. Ranh; Pugh, Thomas J.; Skinner, Heath; Levy, Lawrence B.; Takiar, Vinita; Choi, Seungtaek; Du, Weiliang; Frank, Steven J.; Johnson, Jennifer; Kanke, James; Kudchadker, Rajat J.; Lee, Andrew K.; Mahmood, Usama; McGuire, Sean E.; Kuban, Deborah A.

    2014-04-01

    Objective: To report late toxicity outcomes from a randomized trial comparing conventional and hypofractionated prostate radiation therapy and to identify dosimetric and clinical parameters associated with late toxicity after hypofractionated treatment. Methods and Materials: Men with localized prostate cancer were enrolled in a trial that randomized men to either conventionally fractionated intensity modulated radiation therapy (CIMRT, 75.6 Gy in 1.8-Gy fractions) or to dose-escalated hypofractionated IMRT (HIMRT, 72 Gy in 2.4-Gy fractions). Late (≥90 days after completion of radiation therapy) genitourinary (GU) and gastrointestinal (GI) toxicity were prospectively evaluated and scored according to modified Radiation Therapy Oncology Group criteria. Results: 101 men received CIMRT and 102 men received HIMRT. The median age was 68, and the median follow-up time was 6.0 years. Twenty-eight percent had low-risk, 71% had intermediate-risk, and 1% had high-risk disease. There was no difference in late GU toxicity in men treated with CIMRT and HIMRT. The actuarial 5-year grade ≥2 GU toxicity was 16.5% after CIMRT and 15.8% after HIMRT (P=.97). There was a nonsignificant numeric increase in late GI toxicity in men treated with HIMRT compared with men treated with CIMRT. The actuarial 5-year grade ≥2 GI toxicity was 5.1% after CIMRT and 10.0% after HIMRT (P=.11). In men receiving HIMRT, the proportion of rectum receiving 36.9 Gy, 46.2 Gy, 64.6 Gy, and 73.9 Gy was associated with the development of late GI toxicity (P<.05). The 5-year actuarial grade ≥2 GI toxicity was 27.3% in men with R64.6Gy ≥ 20% but only 6.0% in men with R64.6Gy < 20% (P=.016). Conclusions: Dose-escalated IMRT using a moderate hypofractionation regimen (72 Gy in 2.4-Gy fractions) can be delivered safely with limited grade 2 or 3 late toxicity. Minimizing the proportion of rectum that receives moderate and high dose decreases the risk of late rectal toxicity after this

  16. Risk of Late Toxicity in Men Receiving Dose-Escalated Hypofractionated Intensity Modulated Prostate Radiation Therapy: Results From a Randomized Trial

    International Nuclear Information System (INIS)

    Hoffman, Karen E.; Voong, K. Ranh; Pugh, Thomas J.; Skinner, Heath; Levy, Lawrence B.; Takiar, Vinita; Choi, Seungtaek; Du, Weiliang; Frank, Steven J.; Johnson, Jennifer; Kanke, James; Kudchadker, Rajat J.; Lee, Andrew K.; Mahmood, Usama; McGuire, Sean E.; Kuban, Deborah A.

    2014-01-01

    Objective: To report late toxicity outcomes from a randomized trial comparing conventional and hypofractionated prostate radiation therapy and to identify dosimetric and clinical parameters associated with late toxicity after hypofractionated treatment. Methods and Materials: Men with localized prostate cancer were enrolled in a trial that randomized men to either conventionally fractionated intensity modulated radiation therapy (CIMRT, 75.6 Gy in 1.8-Gy fractions) or to dose-escalated hypofractionated IMRT (HIMRT, 72 Gy in 2.4-Gy fractions). Late (≥90 days after completion of radiation therapy) genitourinary (GU) and gastrointestinal (GI) toxicity were prospectively evaluated and scored according to modified Radiation Therapy Oncology Group criteria. Results: 101 men received CIMRT and 102 men received HIMRT. The median age was 68, and the median follow-up time was 6.0 years. Twenty-eight percent had low-risk, 71% had intermediate-risk, and 1% had high-risk disease. There was no difference in late GU toxicity in men treated with CIMRT and HIMRT. The actuarial 5-year grade ≥2 GU toxicity was 16.5% after CIMRT and 15.8% after HIMRT (P=.97). There was a nonsignificant numeric increase in late GI toxicity in men treated with HIMRT compared with men treated with CIMRT. The actuarial 5-year grade ≥2 GI toxicity was 5.1% after CIMRT and 10.0% after HIMRT (P=.11). In men receiving HIMRT, the proportion of rectum receiving 36.9 Gy, 46.2 Gy, 64.6 Gy, and 73.9 Gy was associated with the development of late GI toxicity (P<.05). The 5-year actuarial grade ≥2 GI toxicity was 27.3% in men with R64.6Gy ≥ 20% but only 6.0% in men with R64.6Gy < 20% (P=.016). Conclusions: Dose-escalated IMRT using a moderate hypofractionation regimen (72 Gy in 2.4-Gy fractions) can be delivered safely with limited grade 2 or 3 late toxicity. Minimizing the proportion of rectum that receives moderate and high dose decreases the risk of late rectal toxicity after this

  17. Analysis of the major factors of influence on the conditions of the intensity modulated radiation therapy planning optimization in head and neck

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Sup [International ST. Mary' s Hospital, Seoul (Korea, Republic of); Yoon, In Ha; Lee, Woo Seok; Back, Geum Mun [Dept. of Radiation Oncology, Asan Medical Center, Seoul (Korea, Republic of)

    2014-06-15

    To derive the most appropriate factors by considering the effects of the major factors when applied to the optimization algorithm, thereby aiding the effective designing of a ideal treatment plan. The eclipse treatment planning system(Eclipse 10.0, Varian, USA) was used in this study. The PBC (Pencil Beam Convolution) algorithm was used for dose calculation, and the DVO (Dose Volume Optimizer 10.0.28) Optimization algorithm was used for intensity modulated radiation therapy. The experimental group consists of patients receiving intensity modulated radiation therapy for the head and neck cancer and dose prescription to two planned target volume was 2.2 Gy and 2.0 Gy simultaneously. Treatment plan was done with inverse dose calculation methods utilizing 6 MV beam and 7 fields. The optimal algorithm parameter of the established plan was selected based on volume dose-priority(Constrain), dose fluence smooth value and the impact of the treatment plan was analyzed according to the variation of each factors. Volume dose-priority determines the reference conditions and the optimization process was carried out under the condition using same ratio, but different absolute values. We evaluated the surrounding normal organs of treatment volume according to the changing conditions of the absolute values of the volume dose-priority. Dose fluence smooth value was applied by simply changing the reference conditions (absolute value) and by changing the related volume dose-priority. The treatment plan was evaluated using Conformal Index, Paddick's Conformal Index, Homogeneity Index and the average dose of each organs. When the volume dose-priority values were directly proportioned by changing the absolute values, the CI values were found to be different. However PCI was 1.299±0.006 and HI was 1.095±0.004 while D5%/D95% was 1.090±1.011. The impact on the prescribed dose were similar. The average dose of parotid gland decreased to 67.4, 50.3, 51.2, 47.1 Gy when the absolute

  18. Effect of body mass index on shifts in ultrasound-based image-guided intensity-modulated radiation therapy for abdominal malignancies

    International Nuclear Information System (INIS)

    Choi, Mehee; Fuller, Clifton D.; Wang, Samuel J.; Siddiqi, Ather; Wong, Adrian; Thomas, Charles R.; Fuss, Martin

    2009-01-01

    Background and purpose: We investigated whether corrective shifts determined by daily ultrasound-based image-guidance correlate with body mass index (BMI) of patients treated with image-guided intensity-modulated radiation therapy (IG-IMRT) for abdominal malignancies. The utility of daily image-guidance, particularly for patients with BMI > 25.0, is examined. Materials and methods: Total 3162 ultrasound-directed shifts were performed in 86 patients. Direction and magnitude of shifts were correlated with pretreatment BMI. Bivariate statistical analysis and analysis of set-up correction data were performed using systematic and random error calculations. Results: Total 2040 daily alignments were performed. Average 3D vector of set-up correction for all patients was 12.1 mm/fraction. Directional and absolute shifts and 3D vector length were significantly different between BMI cohorts. 3D displacement averaged 4.9 mm/fraction and 6.8mm/fraction for BMI ≤ 25.0 and BMI > 25.0, respectively. Systematic error in all axes and 3D vector was significantly greater for BMI > 25.0. Differences in random error were not statistically significant. Conclusions: Set-up corrections derived from daily ultrasound-based IG-IMRT of abdominal tumors correlated with BMI. Daily image-guidance may improve precision of IMRT delivery with benefits assessed for the entire population, particularly patients with increased habitus. Requisite PTV margins suggested in the absence of daily image-guidance are significantly greater in patients with BMI > 25.0.

  19. Will weight loss cause significant dosimetric changes of target volumes and organs at risk in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy?

    International Nuclear Information System (INIS)

    Chen, Chuanben; Fei, Zhaodong; Chen, Lisha; Bai, Penggang; Lin, Xiang; Pan, Jianji

    2014-01-01

    This study aimed to quantify dosimetric effects of weight loss for nasopharyngeal carcinoma (NPC) treated with intensity-modulated radiation therapy (IMRT). Overall, 25 patients with NPC treated with IMRT were enrolled. We simulated weight loss during IMRT on the computer. Weight loss model was based on the planning computed tomography (CT) images. The original external contour of head and neck was labeled plan 0, and its volume was regarded as pretreatment normal weight. We shrank the external contour with different margins (2, 3, and 5 mm) and generated new external contours of head and neck. The volumes of reconstructed external contours were regarded as weight during radiotherapy. After recontouring outlines, the initial treatment plan was mapped to the redefined CT scans with the same beam configurations, yielding new plans. The computer model represented a theoretical proportional weight loss of 3.4% to 13.7% during the course of IMRT. The dose delivered to the planning target volume (PTV) of primary gross tumor volume and clinical target volume significantly increased by 1.9% to 2.9% and 1.8% to 2.9% because of weight loss, respectively. The dose to the PTV of gross tumor volume of lymph nodes fluctuated from −2.0% to 1.0%. The dose to the brain stem and the spinal cord was increased (p < 0.001), whereas the dose to the parotid gland was decreased (p < 0.001). Weight loss may lead to significant dosimetric change during IMRT. Repeated scanning and replanning for patients with NPC with an obvious weight loss may be necessary

  20. Application of monomer/polymer gel dosimetry to study the effects of tissue inhomogeneities on intensity-modulated radiation therapy (IMRT) dose distributions.

    Science.gov (United States)

    Vergote, Koen; De Deene, Yves; Claus, Filip; De Gersem, Werner; Van Duyse, Bart; Paelinck, Leen; Achten, Eric; De Neve, Wilfried; De Wagter, Carlos

    2003-04-01

    When planning an intensity-modulated radiation therapy (IMRT) treatment in a heterogeneous region (e.g. the thorax), the dose computation algorithm of a treatment planning system may need to account for these inhomogeneities in order to obtain a reliable prediction of the dose distribution. An accurate dose verification technique such as monomer/polymer gel dosimetry is suggested to verify the outcome of the planning system. The effects of low-density structures: (a) on narrow high-energy (18 MV) photon beams; and (b) on a class-solution IMRT treatment delivered to a thorax phantom have been examined using gel dosimetry. The used phantom contained air cavities that could be filled with water to simulate a homogeneous or heterogeneous configuration. The IMRT treatment for centrally located lung tumors was delivered on both cases, and gel derived dose maps were compared with computations by both the GRATIS and Helax-TMS planning system. Dose rebuildup due to electronic disequilibrium in a narrow photon beam is demonstrated. The gel measurements showed good agreement with diamond detector measurements. Agreement between measured IMRT dose maps and dose computations was demonstrated by several quantitative techniques. An underdosage of the planning target volume (PTV) was revealed. The homogeneity of the phantom had only a minor influence on the dose distribution in the PTV. An expansion of low-level isodoses in the lung volume was predicted by collapsed cone computations in the heterogeneous case. For the class-solution described, the dose in centrally located mediastinal tumors can be computed with sufficient accuracy, even when neglecting the lower lung density. Polymer gel dosimetry proved to be a valuable technique to verify dose calculation algorithms for IMRT in 3D in heterogeneous configurations.

  1. Analysis of motion of the rectum during preoperative intensity modulated radiation therapy for rectal cancer using cone-beam computed tomography

    International Nuclear Information System (INIS)

    Yamashita, Hideomi; Takenaka, Ryousuke; Sakumi, Akira; Haga, Akihiro; Otomo, Kuni; Nakagawa, Keiichi

    2015-01-01

    The purpose of the present study was to quantify the inter-fractional motion of the rectum and the rectal and bladder volumes using CBCT scans taken during chemoradiation therapy (CRT) for rectal cancer. Also, assessment was made for a better margin for simultaneous integrated boost - intensity modulated radiation therapy (SIB-IMRT) for rectal cancer. There were 32 patients in this study undergoing preoperative CRT for rectal cancer. Each rectum and bladder was contoured on all planning CTs and CBCTs (day 1, 7, 13, 19, 25). The target volume was configured by adding margins (0, 3, 5, 7, 10, and 15 mm) to the rectum on planning CT. The respective percentage of rectal volume that exceeds the target volume was calculated for each of these margins. The percentage of bladder volume that exceeds the bladder volume in the planning CT and motion of the center of gravity of rectum were also analyzed. Planning CTs and series of each 5 CBCTs for 32 patients were analyzed in this study. The rectal volume tended to shrink week after week. The mean values (± SD) in the 32 series per patient of the percentage of rectum on the CBCTs exceeding target volume in which the margins of 0, 3, 5, 7, 10, and 15 mm were added to the rectum on planning CT were 20.7 ± 12.5%, 7.2 ± 8.3%, 3.9 ± 5.9%, 2.1 ± 3.9%, 0.7 ± 1.8%, and 0.1 ± 0.3%, respectively. No association was seen between the percentage of changes of bladder volume and motion of rectal centroid. In this study, we estimated the motion of the rectum using planning CT and CBCT. Ten to fifteen mm is a sufficient margin for the rectum during SIB-IMRT for rectal cancer in the supine position

  2. Preserving Functional Lung Using Perfusion Imaging and Intensity-Modulated Radiation Therapy for Advanced-Stage Non-Small Cell Lung Cancer

    International Nuclear Information System (INIS)

    Shioyama, Yoshiyuki; Jang, Si Young; Liu, H. Helen; Guerrero, Thomas; Wang, Xuanmin; Gayed, Isis W.; Erwin, William D.; Liao, Zhongxing; Chang, Joe Y.; Jeter, Melenda; Yaremko, Brian P.; Borghero, Yerko O.; Cox, James D.; Komaki, Ritsuko; Mohan, Radhe

    2007-01-01

    Purpose: To assess quantitatively the impact of incorporating functional lung imaging into intensity-modulated radiation therapy planning for locally advanced non-small cell lung cancer (NSCLC). Methods and Materials: Sixteen patients with advanced-stage NSCLC who underwent radiotherapy were included in this study. Before radiotherapy, each patient underwent lung perfusion imaging with single-photon-emission computed tomography and X-ray computed tomography (SPECT-CT). The SPECT-CT was registered with simulation CT and was used to segment the 50- and 90-percentile hyperperfusion lung (F50 lung and F90 lung). Two IMRT plans were designed and compared in each patient: an anatomic plan using simulation CT alone and a functional plan using SPECT-CT in addition to the simulation CT. Dosimetric parameters of the two types of plans were compared in terms of tumor coverage and avoidance of normal tissues. Results: In incorporating perfusion information in IMRT planning, the median reductions in the mean doses to the F50 and F90 lung in the functional plan were 2.2 and 4.2 Gy, respectively, compared with those in the anatomic plans. The median reductions in the percentage of volume irradiated with >5 Gy, >10 Gy, and >20 Gy in the functional plans were 7.1%, 6.0%, and 5.1%, respectively, for F50 lung, and 11.7%, 12.0%, and 6.8%, respectively, for F90 lung. A greater degree of sparing of the functional lung was achieved for patients with large perfusion defects compared with those with relatively uniform perfusion distribution. Conclusion: Function-guided IMRT planning appears to be effective in preserving functional lung in locally advanced-stage NSCLC patients

  3. Duodenal and Other Gastrointestinal Toxicity in Cervical and Endometrial Cancer Treated With Extended-Field Intensity Modulated Radiation Therapy to Paraaortic Lymph Nodes

    International Nuclear Information System (INIS)

    Poorvu, Philip D.; Sadow, Cheryl A.; Townamchai, Kanokpis; Damato, Antonio L.; Viswanathan, Akila N.

    2013-01-01

    Purpose: To characterize the rates of acute and late duodenal and other gastrointestinal (GI) toxicities among patients treated for cervical and endometrial cancers with extended-field intensity modulated radiation therapy (EF-IMRT) to the paraaortic nodes and to analyze dose-volume relationships of GI toxicities. Methods and Materials: Fifty-three patients with endometrial or cervical cancer underwent EF-IMRT to the paraaortic nodes, of whom 46 met the inclusion criteria for GI toxicity and 45 for duodenal toxicity analysis. The median prescribed dose to the paraaortic nodes was 54 Gy (range, 41.4-65 Gy). The 4 duodenal segments, whole duodenum, small bowel loops, peritoneum, and peritoneum plus retroperitoneal segments of colon were contoured retrospectively, and dosimetric analysis was performed to identify dose-volume relationships to grade ≥3 acute (<90 day) and late (≥90 day) GI toxicity. Results: Only 3/46 patients (6.5%) experienced acute grade ≥3 GI toxicity and 3/46 patients (6.5%) experienced late grade ≥3 GI toxicity. The median dose administered to these 6 patients was 50.4 Gy. One of 12 patients who received 63 to 65 Gy at the level of the renal hilum experienced grade 3 GI toxicity. Dosimetric analysis of patients with and without toxicity revealed no differences between the mean absolute or fractional volumes at any 5-Gy interval between 5 Gy and the maximum dose. None of the patients experienced duodenal toxicity. Conclusions: Treatment of paraaortic nodes with IMRT is associated with low rates of GI toxicities and no duodenal-specific toxicity, including patients treated with concurrent chemotherapy. This technique may allow sufficient dose sparing of the bowel to enable safe dose escalation to at least 65 Gy

  4. Intensity-modulated radiation therapy and volumetric-modulated arc therapy for adult craniospinal irradiation—A comparison with traditional techniques

    Energy Technology Data Exchange (ETDEWEB)

    Studenski, Matthew T., E-mail: matthew.studenski@jeffersonhospital.org [Department of Radiation Oncology, Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States); Shen, Xinglei; Yu, Yan; Xiao, Ying; Shi, Wenyin [Department of Radiation Oncology, Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States); Biswas, Tithi [Department of Radiation Oncology, Brody School of Medicine, East Carolina University, Greenville, NC (United States); Werner-Wasik, Maria; Harrison, Amy S. [Department of Radiation Oncology, Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States)

    2013-04-01

    Craniospinal irradiation (CSI) poses a challenging planning process because of the complex target volume. Traditional 3D conformal CSI does not spare any critical organs, resulting in toxicity in patients. Here the dosimetric advantages of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) are compared with classic conformal planning in adults for both cranial and spine fields to develop a clinically feasible technique that is both effective and efficient. Ten adult patients treated with CSI were retrospectively identified. For the cranial fields, 5-field IMRT and dual 356° VMAT arcs were compared with opposed lateral 3D conformal radiotherapy (3D-CRT) fields. For the spine fields, traditional posterior-anterior (PA) PA fields were compared with isocentric 5-field IMRT plans and single 200° VMAT arcs. Two adult patients have been treated using this IMRT technique to date and extensive quality assurance, especially for the junction regions, was performed. For the cranial fields, the IMRT technique had the highest planned target volume (PTV) maximum and was the least efficient, whereas the VMAT technique provided the greatest parotid sparing with better efficiency. 3D-CRT provided the most efficient delivery but with the highest parotid dose. For the spine fields, VMAT provided the best PTV coverage but had the highest mean dose to all organs at risk (OAR). 3D-CRT had the highest PTV and OAR maximum doses but was the most efficient. IMRT provides the greatest OAR sparing but the longest delivery time. For those patients with unresectable disease that can benefit from a higher, definitive dose, 3D-CRT–opposed laterals are the most clinically feasible technique for cranial fields and for spine fields. Although inefficient, the IMRT technique is the most clinically feasible because of the increased mean OAR dose with the VMAT technique. Quality assurance of the beams, especially the junction regions, is essential.

  5. Comparative Toxicity and Dosimetric Profile of Whole-Pelvis Versus Prostate Bed-Only Intensity-Modulated Radiation Therapy After Prostatectomy

    Energy Technology Data Exchange (ETDEWEB)

    Deville, Curtiland, E-mail: deville@uphs.upenn.edu [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Vapiwala, Neha [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Hwang, Wei-Ting [Department of Biostatistics and Epidemiology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Lin Haibo; Bar Ad, Voichita; Tochner, Zelig; Both, Stefan [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States)

    2012-03-15

    Purpose: To assess whether whole-pelvis (WP) intensity modulated radiation therapy (IMRT) for prostate cancer (PCa) after prostatectomy is associated with increased toxicity compared to prostate-bed only (PB) IMRT. Methods and Materials: All patients (n = 67) undergoing postprostatectomy IMRT to 70.2 Gy at our institution from January 2006 to January 2009 with minimum 12-month follow-up were divided into WP (n = 36) and PB (n = 31) comparison groups. WP patients received initial pelvic nodal IMRT to 45 Gy. Pretreatment demographics, bladder and rectal dose-volume histograms, and maximum genitourinary (GU) and gastrointestinal (GI) toxicities were compared. Logistic regression models evaluated uni- and multivariate associations between pretreatment demographics and toxicities. Results: Pretreatment demographics including age and comorbidities were similar between groups. WP patients had higher Gleason scores, T stages, and preoperative prostate-specific antigen (PSA) levels, and more WP patients underwent androgen deprivation therapy (ADT). WP minimum (Dmin) and mean bladder doses, bladder volumes receiving more than 5 Gy (V5) and V20, rectal Dmin, and PB bladder and rectal V65 were significantly increased. Maximum acute GI toxicity was Grade 2 and was increased for WP (61%) vs. PB (29%) patients (p = 0.001); there was no significant difference in acute Grade {>=}2 GU toxicity (22% WP vs. 10% PB; p = 0.193), late Grade {>=}2 GI toxicity (3% WP vs. 0% PB; p = 0.678), or late Grade {>=}2 GU toxicity (28% WP vs. 19% PB; p = 0.274) with 25-month median follow-up (range, 12-44 months). On multivariate analysis, long-term ADT use was associated with Grade {>=}2 late GU toxicity (p = 0.02). Conclusion: Despite dosimetric differences in irradiated bowel, bladder, and rectum, WP IMRT resulted only in clinically significant increased acute GI toxicity in comparison to that with PB IMRT, with no differences in GU or late GI toxicity.

  6. Application of monomer/polymer gel dosimetry to study the effects of tissue inhomogeneities on intensity-modulated radiation therapy (IMRT) dose distributions

    International Nuclear Information System (INIS)

    Vergote, Koen; Deene, Yves de; Claus, Filip; Gersem, Werner de; Duyse, Bart van; Paelinck, Leen; Achten, Eric; Neve, Wilfried de; Wagter, Carlos de

    2003-01-01

    Background and purpose: When planning an intensity-modulated radiation therapy (IMRT) treatment in a heterogeneous region (e.g. the thorax), the dose computation algorithm of a treatment planning system may need to account for these inhomogeneities in order to obtain a reliable prediction of the dose distribution. An accurate dose verification technique such as monomer/polymer gel dosimetry is suggested to verify the outcome of the planning system. Materials and methods: The effects of low-density structures: (a) on narrow high-energy (18 MV) photon beams; and (b) on a class-solution IMRT treatment delivered to a thorax phantom have been examined using gel dosimetry. The used phantom contained air cavities that could be filled with water to simulate a homogeneous or heterogeneous configuration. The IMRT treatment for centrally located lung tumors was delivered on both cases, and gel derived dose maps were compared with computations by both the GRATIS and Helax-TMS planning system. Results: Dose rebuildup due to electronic disequilibrium in a narrow photon beam is demonstrated. The gel measurements showed good agreement with diamond detector measurements. Agreement between measured IMRT dose maps and dose computations was demonstrated by several quantitative techniques. An underdosage of the planning target volume (PTV) was revealed. The homogeneity of the phantom had only a minor influence on the dose distribution in the PTV. An expansion of low-level isodoses in the lung volume was predicted by collapsed cone computations in the heterogeneous case. Conclusions: For the class-solution described, the dose in centrally located mediastinal tumors can be computed with sufficient accuracy, even when neglecting the lower lung density. Polymer gel dosimetry proved to be a valuable technique to verify dose calculation algorithms for IMRT in 3D in heterogeneous configurations

  7. Acute gastrointestinal and genitourinary toxicity of image-guided intensity modulated radiation therapy for prostate cancer using a daily water-filled endorectal balloon

    International Nuclear Information System (INIS)

    Deville, Curtiland; Both, Stefan; Bui, Viet; Hwang, Wei-Ting; Tan, Kay-See; Schaer, Mattia; Tochner, Zelig; Vapiwala, Neha

    2012-01-01

    Our purpose was to report acute gastrointestinal (GI) and genitourinary (GU) toxicity rates for prostate cancer patients undergoing image-guided intensity modulated radiation therapy (IG-IMRT) with a daily endorectal water-filled balloon (ERB H2O ), and assess associations with planning parameters and pretreatment clinical characteristics. The first 100 patients undergoing prostate and proximal seminal vesicle IG-IMRT with indexed-lumen 100 cc ERB H2O to 79.2 Gy in 1.8 Gy fractions at our institution from 12/2008- 12/2010 were assessed. Pretreatment characteristics, organ-at-risk dose volume histograms, and maximum GU and GI toxicities (CTCAE 3.0) were evaluated. Logistic regression models evaluated univariate association between toxicities and dosimetric parameters, and uni- and multivariate association between toxicities and pretreatment characteristics. Mean age was 68 (range 51–88). Thirty-two, 49, and 19 patients were low, intermediate, and high-risk, respectively; 40 received concurrent androgen deprivation. No grade 3 or greater toxicities were recorded. Maximum GI toxicity was grade 0, 1, and 2 in 69%, 23%, and 8%, respectively. Infield (defined as 1 cm above/below the CTV) rectal mean/median doses, D75, V30, and V40 and hemorrhoid history were associated with grade 2 GI toxicity (Ps < 0.05). Maximum acute GU toxicity was grade 0, 1, and 2 for 17%, 41%, and 42% of patients, respectively. Infield bladder V20 (P = 0.03) and pretreatment International Prostate Symptom Scale (IPSS) (P = 0.003) were associated with grade 2 GU toxicity. Prostate IG-IMRT using a daily ERB H2O shows low rates of acute GI toxicity compared to previous reports of air-filled ERB IMRT when using stringent infield rectum constraints and comparable GU toxicities

  8. Sequential chemotherapy and intensity-modulated radiation therapy in the management of locoregionally advanced nasopharyngeal carcinoma: Experience of 370 consecutive cases

    Directory of Open Access Journals (Sweden)

    Chen Qisong

    2010-02-01

    Full Text Available Abstract Introduction To investigate the outcome of locoregionally advanced nasopharyngeal carcinoma (NPC treated with intensity-modulated radiation therapy (IMRT after induction chemotherapy, with or without concomitant chemotherapy. Methods Between August 2003 and March 2007, 370 patients with locoregionally advanced NPC were treated with IMRT. Presenting stages were stage IIB in 62, stage III in 197, and stage IVA/B in 111 patients. All patients except for 36 patients with cervical lymphadenopathy of 4 cm or less in diameter received 2 cycles of cisplatin-based neoadjuvant chemotherapy. Forty-eight patients received cisplatin-based concurrent chemotherapy as well. Results With a median follow-up time of 31 months (range 5 to 61 months, the 3-year local control, regional control, metastasis-free survival (MFS, disease-free survival (DFS and overall survival (OS rates were 95%, 97%, 86%, 81% and 89%, respectively. Multivariate analyses revealed that both age (≤ 60 vs. >60 and N-classification are significant prognosticators for OS (P = 0.001, hazard ratio [HR] 2.395, 95% confidence interval [CI] 1.432-4.003; P = 0.012, hazard ratio [HR] 2.614, 95% confidence interval [CI] 1.235-5.533; And N-classification is the only significant predicative factor for MFS (P = 0.002, [HR] 1.99, 95% CI 1.279-3.098. T-classification and concurrent chemotherapy were not significant prognostic factors for local/regional control, MFS, DFS, or OS. Subgroup analysis revealed that concurrent chemotherapy provided no significant benefit to IMRT in locoregionally advanced NPC, but was responsible for higher rates of grade 3 or 4 acute toxicities (50% vs. 29.8%, P Conclusion IMRT following neoadjuvant chemotherapy produced a superb outcome in terms of local control, regional control, MFS, DFS, and OS rates in patients with stage IIB to IVB NPC. Effective treatment strategy is urgently needed for distant control in patients diagnosed with locoregionally advanced NPC.

  9. Cognitive function, mood, and sleep quality in patients treated with intensity-modulated radiation therapy for nasopharyngeal cancer: a prospective study.

    Science.gov (United States)

    Mo, Yan-Lin; Li, Ling; Qin, Ling; Zhu, Xiao-Dong; Qu, Song; Liang, Xia; Wei, Zhou-Ji

    2014-10-01

    The aim of this study was to prospectively evaluate the cognitive function, depression, anxiety, and sleep quality in patients with nasopharyngeal cancer (NPC) before and after intensity-modulated radiotherapy (IMRT). Eligible patients with newly diagnosed NPC treated with primary IMRT were recruited. A series of neuropsychological tests were performed within 1 week before and after IMRT. Cognitive function was measured with the Das-Naglieri cognitive assessment system. The Self-rating Anxiety Scale and Self-rating Depression Scale were used to assess mood states. Sleep quality was evaluated by means of the Pittsburgh Sleep Quality Index. A total of 51 patients were enrolled. The overall prevalence of depression, anxiety, and poor sleep quality showed a significant increase after RT, compared with their pre-RT levels (39.2% vs. 3.9%, p = 0.000; 19.6% vs. 3.9%, p = 0.039; 64.7% vs. 37.3%, p = 0.003, respectively). Multiple linear regression analysis revealed that pre-RT depression and younger age and pre-RT anxiety and younger age were significant predictors of post-RT depression and anxiety, respectively (p sleep quality before treatment was also associated with poor sleep after RT (p = 0.032). However, the cognitive function evaluated by the cognitive assessment system from pre-RT was similar to the post-RT results. Exposure to ionizing radiation for the treatment of NPC decreased mood and sleep quality following IMRT, especially for patients with depression, anxiety, younger age, or poor sleep before treatment. No acute cognitive deficits were found resulting from IMRT, but the long-term effects of RT might still warrant concern. Copyright © 2014 John Wiley & Sons, Ltd.

  10. Interfractional and intrafractional errors assessed by daily cone-beam computed tomography in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy. A prospective study

    International Nuclear Information System (INIS)

    Lu Heming; Lin Hui; Feng Guosheng

    2012-01-01

    This prospective study was to assess interfractional and intrafractional errors and to estimate appropriate margins for planning target volume (PTV) by using daily cone-beam computed tomography (CBCT) guidance in nasopharyngeal carcinoma (NPC). Daily pretreatment and post-treatment CBCT scans were acquired separately after initial patient setup and after the completion of each treatment fraction in 10 patients treated with intensity-modulated radiation therapy (IMRT). Online corrections were made before treatment if any translational setup error was found. Interfractional and intrafractional errors were recorded in the right-left (RL), superior-inferior (SI) and anterior-posterior (AP) directions. For the translational shifts, interfractional errors >2 mm occurred in 21.7% of measurements in the RL direction, 12.7% in the SI direction and 34.1% in the AP direction, respectively. Online correction resulted in 100% of residual errors ≤2 mm in the RL and SI directions, and 95.5% of residual errors ≤2 mm in the AP direction. No residual errors >3 mm occurred in the three directions. For the rotational shifts, a significant reduction was found in the magnitudes of residual errors compared with those of interfractional errors. A margin of 4.9 mm, 4.0 mm and 6.3 mm was required in the RL, SI and AP directions, respectively, when daily CBCT scans were not performed. With daily CBCT, the margins were reduced to 1.2 mm in all directions. In conclusion, daily CBCT guidance is an effective modality to improve the accuracy of IMRT for NPC. The online correction could result in a 70-81% reduction in margin size. (author)

  11. Measurements of photon and neutron leakage from medical linear accelerators and Monte Carlo simulation of tenth value layers of concrete used for intensity modulated radiation therapy treatment

    Science.gov (United States)

    Jaradat, Adnan Khalaf

    The x ray leakage from the housing of a therapy x ray source is regulated to be chamber and track-etch detectors. The leakage was measured at nine different positions over the rear wall using a 3 x 3 matrix with a 1 m separation between adjacent positions. In general, the leakage was less than the canonical value, but the exact value depends on energy, gantry angle, and measurement position. Leakage at 10 MV for some positions exceeded 0.1%. Electrons with energy greater than about 9 MeV have the ability to produce neutrons. Neutron leakage has been measured around the head of electron accelerators at a distance 1 m from the target at 0°, 46°, 90°, 135°, and 180° azimuthal angles; for electron energies of 9, 12, 15, 16, 18, and 20 MeV and 10, 15, and 18 MV x ray photon beam, using a neutron bubble detector of type BD-PND and using Track-Etch detectors. The highest neutron dose equivalent per unit electron dose was at 0° for all electron energies. The neutron leakage from photon beams was the highest between all the machines. Intensity modulated radiation therapy (IMRT) delivery consists of a summation of small beamlets having different weights that make up each field. A linear accelerator room designed exclusively for IMRT use would require different, probably lower, tenth value layers (TVL) for determining the required wall thicknesses for the primary barriers. The first, second, and third TVL of 60Co gamma rays and photons from 4, 6, 10, 15, and 18 MV x ray beams by concrete have been determined and modeled using a Monte Carlo technique (MCNP version 4C2) for cone beams of half-opening angles of 0°, 3°, 6°, 9°, 12°, and 14°.

  12. Stereotactic body radiation therapy for abdominal targets using volumetric intensity modulated arc therapy with RapidArc: Feasibility and clinical preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Scorsetti, Marta; Bignardi, Mario; Alongi, Filippo; Mancosu, Pietro; Navarria, Piera; Castiglioni, Simona; Pentimalli, Sara; Tozzi, Angelo (IRCCS Istituto Clinico Humanitas, Rozzano (Italy)), e-mail: pietro.mancosu@humanitas.it; Fogliata, Antonella; Cozzi, Luca (Oncology Inst. of Southern Switzerland, Bellinzona (Switzerland))

    2011-05-15

    Purpose. To report early clinical experience in stereotactic body radiation therapy (SBRT) delivered using volumetric intensity modulated arc therapy with RapidArc (RA) in patients with primary or metastatic tumours at abdominal sites. Material and methods. Thirty-seven consecutive patients were treated using RA. Of these, 16 had primary or metastatic liver tumours, nine had pancreatic cancer and 12 a nodal metastasis in the retro-peritoneum. Dose prescription varied from 45 to 75 Gy to the Clinical Target Volume in 3 to 6 fractions. The median follow-up was 12 months (6-22). Early local control and toxicity were investigated and reported. Results. Planning objectives on target volumes and organs at risk were met in most cases. Delivery time ranged from 2.8 +- 0.3 to 9.2 +- 2.4 minutes and pre-treatment plan verification resulted in a Gamma Agreement Index from 95.3 +- 3.8 to 98.3 +- 1.7%. At the time of analysis, local control (freedom from progression) at six months, was assessable in 24 of 37 patients and was achieved in 19 patients with a crude rate of 79.2%. Seven patients experienced treatment-related toxicity. Three patients experienced a mild and transient G1 enteritis and two showed a transient G1 liver damage. Two had late toxicity: one developed chronic enteritis causing G1 diarrhoea and G1 abdominal pain and one suffered at three months a G3 gastric bleeding. No patients experienced G4 acute toxicity. Conclusions. SBRT for abdominal targets delivered by means of RA resulted to be feasible with good early clinical results in terms of local control rate and acute toxicity profile. RA allowed to achieve required target coverage as well as to keep within normal tissue dose/volume constraints

  13. Fully Automated Simultaneous Integrated Boosted-Intensity Modulated Radiation Therapy Treatment Planning Is Feasible for Head-and-Neck Cancer: A Prospective Clinical Study

    Energy Technology Data Exchange (ETDEWEB)

    Wu Binbin, E-mail: binbin.wu@gunet.georgetown.edu [Department of Radiation Oncology and Molecular Radiation Science, Johns Hopkins University, Baltimore, Maryland (United States); Department of Radiation Medicine, Georgetown University Hospital, Washington, DC (United States); McNutt, Todd [Department of Radiation Oncology and Molecular Radiation Science, Johns Hopkins University, Baltimore, Maryland (United States); Zahurak, Marianna [Department of Oncology Biostatistics, Johns Hopkins University, Baltimore, Maryland (United States); Simari, Patricio [Autodesk Research, Toronto, ON (Canada); Pang, Dalong [Department of Radiation Medicine, Georgetown University Hospital, Washington, DC (United States); Taylor, Russell [Department of Computer Science, Johns Hopkins University, Baltimore, Maryland (United States); Sanguineti, Giuseppe [Department of Radiation Oncology and Molecular Radiation Science, Johns Hopkins University, Baltimore, Maryland (United States)

    2012-12-01

    Purpose: To prospectively determine whether overlap volume histogram (OVH)-driven, automated simultaneous integrated boosted (SIB)-intensity-modulated radiation therapy (IMRT) treatment planning for head-and-neck cancer can be implemented in clinics. Methods and Materials: A prospective study was designed to compare fully automated plans (APs) created by an OVH-driven, automated planning application with clinical plans (CPs) created by dosimetrists in a 3-dose-level (70 Gy, 63 Gy, and 58.1 Gy), head-and-neck SIB-IMRT planning. Because primary organ sparing (cord, brain, brainstem, mandible, and optic nerve/chiasm) always received the highest priority in clinical planning, the study aimed to show the noninferiority of APs with respect to PTV coverage and secondary organ sparing (parotid, brachial plexus, esophagus, larynx, inner ear, and oral mucosa). The sample size was determined a priori by a superiority hypothesis test that had 85% power to detect a 4% dose decrease in secondary organ sparing with a 2-sided alpha level of 0.05. A generalized estimating equation (GEE) regression model was used for statistical comparison. Results: Forty consecutive patients were accrued from July to December 2010. GEE analysis indicated that in APs, overall average dose to the secondary organs was reduced by 1.16 (95% CI = 0.09-2.33) with P=.04, overall average PTV coverage was increased by 0.26% (95% CI = 0.06-0.47) with P=.02 and overall average dose to the primary organs was reduced by 1.14 Gy (95% CI = 0.45-1.8) with P=.004. A physician determined that all APs could be delivered to patients, and APs were clinically superior in 27 of 40 cases. Conclusions: The application can be implemented in clinics as a fast, reliable, and consistent way of generating plans that need only minor adjustments to meet specific clinical needs.

  14. Systemic chemotherapy followed by locoregional definitive intensity-modulated radiation therapy yields prolonged survival in nasopharyngeal carcinoma patients with distant metastasis at initial diagnosis.

    Science.gov (United States)

    Hu, Shao-xuan; He, Xiao-hui; Dong, Mei; Jia, Bo; Zhou, Sheng-yu; Yang, Jian-liang; Yang, Sheng; Zhang, Chang-Gong; Liu, Peng; Qin, Yan; Gui, Lin

    2015-09-01

    Chemotherapy is the current mainstay of treatment for patients with newly diagnosed metastatic nasopharyngeal carcinoma (NPC), whereas the role of locoregional radiotherapy remains to be defined. In this study, we retrospectively evaluated the outcome of systemic chemotherapy followed by locoregional definitive intensity-modulated radiation therapy (IMRT) as first-line treatment for these patients. Forty-one patients with pathologically confirmed NPC with distant metastasis at initial diagnosis seen between March 2005 and February 2014 were included. All the patients were treated with platinum-based systemic chemotherapy followed by definitive IMRT to the primary head and neck region with or without concurrent chemotherapy. In addition, local treatment to metastatic lesions was given in 19 patients. With a median follow-up time of 25 months, 24 patients had died, and the estimated median overall survival time was 31.2 months. The 1-, 2-, 3- and 5-year estimated OS rates were 89.9, 67.4, 41.1 and 22.5%, respectively. Prognostic analyses showed that serum lactate dehydrogenase level (P = 0.021) and number of metastatic sites (single vs. multiple; P = 0.016) were significant prognostic factors. Five patients are still alive without evidence of disease after 52 to >101 months. All of them had a single metastatic lesion and received local treatment to metastatic sites. These results suggest that the use of definitive IMRT to treat the locoregional tumor in combination with systemic chemotherapy may prolong survival in patients with newly diagnosed metastatic NPC, making curability a possible consideration in selected patients with single metastasis. Further prospective clinical trials are warranted.