WorldWideScience

Sample records for tomography virtual hysterosalpingography

  1. Hysterosalpingography

    Science.gov (United States)

    ... For Patients Search FAQs Hysterosalpingography Page Navigation ▼ ACOG Pregnancy Book Hysterosalpingography Patient Education FAQs Hysterosalpingography Patient Education Pamphlets - Spanish Hysterosalpingography FAQ143, ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... Hysterosalpingography Hysterosalpingography uses a real-time form of x-ray called fluoroscopy to examine the uterus and fallopian ... is Hysterosalpingography? Hysterosalpingography, also called uterosalpingography, is an x-ray examination of a woman's uterus and fallopian tubes ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... and to determine the presence and severity of tumor masses, adhesions and uterine fibroids. Hysterosalpingography can occasionally ... the presence and severity of these abnormalities, including: Tumor masses Adhesions Uterine fibroids Hysterosalpingography is also used ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... Index A-Z Hysterosalpingography Hysterosalpingography uses a real-time form of x-ray called fluoroscopy to examine ... or an untreated sexually transmitted disease at the time of the procedure. On the night before the ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... a variety of abnormalities that cause infertility or problems carrying a fetus to term. Hysterosalpingography can occasionally ... may be evaluated with MRI or ultrasound. Infertility problems may be from causes not evaluated with hysterosalpingography, ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Hysterosalpingography Hysterosalpingography uses a ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... Safety Images related to Hysterosalpingography Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  8. Hysterosalpingography

    International Nuclear Information System (INIS)

    Barbosa, J.R.; Barbosa, A.A.R.; Martins, A. Andre; Botter, L.C.; Barbosa, N.R.; Milano Filho, D.

    1987-01-01

    Several radiographics records with typical roentgen features in hysterosalpingography are presented. Congenital anomalies, myomas, polypus, hyperplasia of endometrium, adenomyosis, synechias, uterine carcinoma, tuba uterine and cervical canal alterations, caesarean section are briefly discussed. (M.A.C.) [pt

  9. Hysterosalpingography

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Hysterosalpingography is a minimally invasive procedure with ... in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... disease-related blockage top of page How should I prepare? The hysterosalpingography procedure is best performed one ... within 30 minutes. top of page What will I experience during and after the procedure? This exam ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... I prepare? The hysterosalpingography procedure is best performed one week after menstruation but before ovulation to make ... for this examination consists of a radiographic table, one or two x-ray tubes and a television- ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... and assess their anatomy and function. top of page What are some common uses of the procedure? Hysterosalpingography ... information about pregnancy and x-rays. top of page What does the equipment look like? The equipment typically ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... cause infertility or problems carrying a fetus to term. Hysterosalpingography can occasionally open fallopian tubes that are ... these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 Radiological ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... information on a variety of abnormalities that cause infertility or problems carrying a fetus to term. Hysterosalpingography ... structures may be evaluated with MRI or ultrasound. Infertility problems may be from causes not evaluated with ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... the procedure? Hysterosalpingography is primarily used to examine women who have difficulty becoming pregnant by allowing the ... that might interfere with the x-ray images. Women should always inform their physician and x-ray ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Hysterosalpingography is a minimally invasive procedure with rare ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... sterilization or disease-related blockage top of page How should I prepare? The hysterosalpingography procedure is best ... on which the patient lies. top of page How does the procedure work? X-rays are a ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Hysterosalpingography is a minimally invasive procedure with rare ... images for evaluation. National and international radiology protection organizations continually review and update the technique standards used ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? Hysterosalpingography is primarily used to examine women ... and x-rays. top of page What does the equipment look like? The equipment typically used for ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... variety of abnormalities that cause infertility or problems carrying a fetus to term. Hysterosalpingography can occasionally open ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  1. 64-Row multidetector CT virtual hysterosalpingography. Findings in 2500 patients

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Capunay, Carlos; Baronio, Mariano; Vallejos, Javier; Papier, Sergio; Carrascosa, Jorge

    2011-01-01

    Objective. To depict typical features of virtual hysterosalpingography (VHSG) in infertile patients. Material and methods: 2500 VHSG performed using a 64-row MOCT were evaluated. Results: Cervical abnormalities visualized corresponded to parietal irregularities (21%); thickened folds (9%); polyps (11%); diverticula (5%); cervical strictures (8%), and synechiae (1.5%). At the level of uterine cavity, polyps (44%); submucous myomas (8%); intramural and subserosal fibroids (11%); synechiae (10%); malformations (10%); adenomyosis (4%), and cesarean section scar (3%). Unilateral hydrosalpinx (7%) and bilateral hydrosalpinx (2%). Tubal obstruction was reported in 6% of cases. The average radiation dose was 0.94 mSv. Eighty-four percent of the patients reported mild pain or no postoperative discomfort. Conclusions: The virtual hysterosalpingography allowed a proper assessment of the internal genital organs, providing useful diagnostic information on infertility and other gynecological disorders. It constitutes a virtually painless, low-dose radiation technique, besides being well tolerated by patients

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... evaluated with hysterosalpingography, including, but not limited to, low or abnormal sperm count or the inability of a fertilized egg to implant in the uterus. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers top of page This page ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... the equipment look like? How does the procedure work? How is the procedure performed? What will I experience during and after the procedure? Who interprets the results and how do I get them? What are the benefits vs. risks? What are the limitations of Hysterosalpingography? What is ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... uterus and fallopian tubes are filled with a water-soluble contrast material and the radiologist is able to use fluoroscopy to view and assess their anatomy and function. top of page What are some common uses of the procedure? Hysterosalpingography is primarily used to examine women ...

  5. Is hysterosalpingography still relevant in workup of infertility? A ...

    African Journals Online (AJOL)

    Materials: Electronic search of published literature was done using the Pubmed, Cochrane libraries and Google search engine. The search was restricted to English language articles. Conclusion: Hysterosalpingography is a simple method of evaluating fallopian tube patency and cervicouterine abnormalities. It is virtually ...

  6. Hysterosalpingography and salpingitis isthmica nodosa

    International Nuclear Information System (INIS)

    Hoffland, G.A.

    1987-01-01

    Over a period of 2 years five patients were seen with typical radiographic findings of salpingitis isthmica nodosa out of 212 cases of hysterosalpingography. The condition is characterized by small diverticula in the Fallopian tubes, generally localized in the isthmic portion and sometimes in the ampulla, unilaterally or bilaterally, and is frequently associated with hydrosalpinx. Salpingitis isthmica nodosa can be the cause of primary or secondary infertility and can increase the incidence of ectopic pregnancy. Recognition of this condition is therefore of importance. 11 refs.; 5 figs.; 2 tabs

  7. Hysterosalpingography versus sonohysterography for intrauterine abnormalities.

    Science.gov (United States)

    Acholonu, Uchenna C; Silberzweig, James; Stein, Daniel E; Keltz, Martin

    2011-01-01

    The hysterosalpingogram is commonly used to evaluate the uterine cavity and the fallopian tubes in the workup of infertile couples. The sonohysterogram is gaining popularity as part of this evaluation. This study compares hysterosalpingography to sonohysterography for the detection of polyps, cavitary fibroids, adhesions, and septae in infertile patients. We conducted a retrospective chart review of 149 infertility patients seen at a University Hospital Center, divisions of Reproductive Endocrinology and Interventional Radiology. Patients underwent hysterosalpingography and sonohysterography as part of their infertility evaluation. The reports were reviewed and findings like polyps, fibroids, adhesions, and septae were compared to the findings obtained at the time of hysteroscopy. Sensitivity, specificity, and accuracy of radiologic tests were the main outcome measures. The sensitivity of hysterosalpingography and sonohysterography was 58.2% and 81.8%, respectively. The specificity for hysterosalpingography and sonohysterography was 25.6% and 93.8%. The differences in sensitivity and specificity were both statistically significant. Hysterosalpingography had a general accuracy of 50.3%, while sonohysterography had a significantly higher accuracy of 75.5%. Although hysterosalpingography is the standard screening test for the diagnosis of tubal infertility and can provide useful information about the uterine cavity, sonohysterography is more sensitive, specific, and accurate in the evaluation of the uterine cavity.

  8. Efficacy of virtual computerized tomography laparoscopy for retroperitoneoscopic nephrectomy

    International Nuclear Information System (INIS)

    Shigeta, Masanobu; Kadonishi, Yuichi; Yasumoto, Hiroaki; Mita, Koji; Usui, Tsuguru; Marukawa, Kazushi

    2004-01-01

    Retroperitoneoscopic nephrectomy is less invasive than open nephrectomy, and is an alternative surgical procedure for renal tumors and upper urothelial tumors. We evaluated the efficacy of virtual computerized tomography laparoscopy (VCTL) as a navigator for retroperitoneoscopic nephrectomy to ascertain the correct anatomy of the renal hilum pre-operatively under the retroperitoneoscopic view. Seventy-three kidneys with localized renal tumors (n=44), upper urothelial tumors (n=23), or benign renal disease (n=6) underwent multidetector-row CT. VCTL was carried out by the volume-rendered technique. The findings were compared with those of real retroperitoneoscopy. After the operation, each operator scored 1 to 5 in evaluating the usefulness of virtual retroperitoneoscopy (score 5 indicated very useful). The percentages of renal arteries depicted by VCTL compared with those noted during real surgery were 93% for kidneys with renal tumors, 100% for upper urothelial tumors and 83% for benign renal disease. Two renal arteries of 2 kidneys were not detected by virtual imaging. These were about 1 mm in diameter and directly branched from the aorta, however retroperitoneoscopic nephrectomy was performed uneventfully. VCTL depicted all the renal veins. The anatomy of the renal hilum seen on VCTL and real retroperitoneoscopy was identical, without the minor angle deviation caused by drawing the kidney during the operation. The average score for the usefulness of VCTL was 4.1, ranging from 3 to 5. The accurate surgical anatomy of the renal hilum could be predicted in almost all patients pre-operatively. VCTL is an excellent navigator for retroperitoneoscopic nephrectomy. (author)

  9. Tubal abnormalities on hysterosalpingography in primary and ...

    African Journals Online (AJOL)

    Summary. Background: Hysterosalpingography (HSG) is an imaging modality used in assessing the fallopian tubes of patients with infertility. There have been reports suggesting that tubal pathologies may be responsible for most cases of sec- ondary infertility. Objective: To evaluate the fallopian tube of women with in-.

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed regularly by a physician with ... not responsible for the content contained on the web pages found at these links. About Us | Contact ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... images and send a signed report to your primary care or referring physician , who will discuss the ... inflammatory condition, pelvic infection or untreated sexually transmitted disease, be certain to notify the physician or technologist ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... of x-ray called fluoroscopy to examine the uterus and fallopian tubes of a woman who is ... to investigate miscarriages resulting from abnormalities within the uterus and to determine the presence and severity of ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... of the fallopian tubes, and to monitor the effects of tubal surgery, including: Blockage of the fallopian ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... It’s also used to investigate miscarriages resulting from abnormalities within the uterus and to determine the presence ... repeated miscarriages that result from congenital or acquired abnormalities of the uterus and to determine the presence ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... a large photographic negative). Today, most images are digital files that are stored electronically. These stored images ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... exam table, with her knees bent or her feet held up with stirrups and a speculum is ... information you were looking for? Yes No Please type your comment or suggestion into the following text ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... medical imaging. Fluoroscopy is a special x-ray technique that makes it possible to see internal organs ... image contrast to white), this special x-ray technique makes it possible for the physician to view ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... consists of a radiographic table, one or two x-ray tubes and a television-like monitor that is located in the examining room. Fluoroscopy, which converts x-rays into video images, is used to watch and ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers top of page This page was reviewed on February 10, 2018 Send us your feedback Did you find the information you were looking for? Yes No Please type your comment or suggestion into the following text ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... the uterus. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers top ... To locate a medical imaging or radiation oncology provider in your community, you can search the ACR- ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... through the body, recording an image on photographic film or a special detector. Fluoroscopy uses a continuous ... recently, x-ray images were maintained on large film sheets (much like a large photographic negative). Today, ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is taken ... for the content contained on the web pages found at these links. About Us | Contact Us | FAQ | ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... uterus and fallopian tubes are filled with a water-soluble contrast material and the radiologist is able ... more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special ... About Us | Contact Us | FAQ | ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... and send a signed report to your primary care or referring physician , who will discuss the results ... rays. A Word About Minimizing Radiation Exposure Special care is taken during x-ray examinations to use ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... of Use | Links | Site Map Copyright © 2018 Radiological Society of North America, Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... the area being examined by making it appear dark (or by electronically reversing the image contrast to ... x-ray examination. X-rays usually have no side effects in the typical diagnostic range for this ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... one or two x-ray tubes and a television-like monitor that is located in the examining ... that are projected onto a fluorescent screen, or television-like monitor. When used with a contrast material, ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available ... having difficulty becoming pregnant. It’s also used to investigate miscarriages resulting from abnormalities within the uterus and ... abdominal) cavity . The procedure can be used to investigate repeated miscarriages that result from congenital or acquired ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... minimize radiation exposure to the baby. See the Safety page for more information about pregnancy and x- ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... white), this special x-ray technique makes it possible for the physician to view joints or internal organs in motion. Still images or movies are also captured and stored electronically on a computer. Until recently, x-ray images were maintained on large film ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site ... clothing that might interfere with the x-ray images. Women should always inform their physician and x- ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... the body. X-rays are the oldest and most frequently used form of medical imaging. Fluoroscopy is ... light or radio waves. X-rays pass through most objects, including the body. Once it is carefully ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, treatments ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... of a fertilized egg to implant in the uterus. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers top of page This page was reviewed on ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... medications being taken and if there are any allergies, especially to iodinated contrast materials . Also inform your ... information you were looking for? Yes No Please type your comment or suggestion into the following text ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... frequently compared to current x-ray images for diagnosis and disease management. top of page How is the procedure ... to radiation. However, the benefit of an accurate diagnosis far outweighs the ... transmitted disease, be certain to notify the physician or technologist ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... Survey Do you have a personal story about radiology? Share your patient story here Related Articles and ... Bleeding Cervical Cancer Endometrial Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ... message (optional): Bees: Wax: Notice: RadiologyInfo respects your privacy. Information entered here will not be used for ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... jewelry, removable dental appliances, eye glasses and any metal objects or clothing that might interfere with the ... ovaries, wall of the uterus, and other pelvic structures may be evaluated with MRI or ultrasound. Infertility ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... or technologist if you have a chronic pelvic infection or an untreated sexually transmitted disease. Wear loose, ... including: Blockage of the fallopian tubes due to infection or scarring Tubal ligation The closure of the ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... remains in a patient's body after an x-ray examination. X-rays usually have no side effects in the ... Articles and Media Sonohysterography Uterine Fibroid Embolization (UFE) Radiation Dose in X-Ray and CT Exams Contrast Materials Abnormal Vaginal ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... The video is produced by the x-ray machine and a detector that is suspended over a ... of the body being examined, an x-ray machine produces a small burst of radiation that passes ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... a large photographic negative). Today, most images are digital files that are stored electronically. These stored images ... physicians with expertise in several radiologic areas. Outside links: For the convenience of our users, RadiologyInfo .org ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... the area being examined by making it appear dark (or by electronically reversing the image contrast to ... the patient is carefully positioned underneath the fluoroscopy camera. The contrast material then begins to fill the ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... the patient is carefully positioned underneath the fluoroscopy camera. The contrast material then begins to fill the uterine cavity , fallopian tubes and peritoneal cavity through the catheter and fluoroscopic images are taken. In some cases, if certain abnormalities are encountered, the ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... x-ray technique that makes it possible to see internal organs in motion. During a hysterosalpingogram, the ... taken to minimize radiation exposure to the baby. See the Safety page for more information about pregnancy ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available ... Share your patient story here Related Articles and Media Sonohysterography Uterine Fibroid Embolization (UFE) Radiation Dose in ... or your insurance provider to get a better understanding of the possible charges you will incur. Web ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... pregnant. Many imaging tests are not performed during pregnancy so as not to expose the fetus to ... See the Safety page for more information about pregnancy and x-rays. top of page What does ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... or internal organs in motion. Still images or movies are also captured and stored electronically on a ... also be minimal and not long lasting. Most women experience vaginal spotting for a few days after ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... you have any signs of pelvic infection or pelvic inflammatory disease. You will be asked to remove some of ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... areas. Outside links: For the convenience of our users, RadiologyInfo .org provides links to relevant ... To help ensure current and accurate information, we do not permit copying but encourage linking ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... an untreated sexually transmitted disease. Wear loose, comfortable clothing and leave jewelry at home. You may be ... appliances, eye glasses and any metal objects or clothing that might interfere with the x-ray images. ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... a chronic inflammatory condition, pelvic infection or untreated sexually transmitted disease, be certain to notify the physician or technologist before the procedure to avoid worsening of infection. Women should always inform their physician or x-ray ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... Wear loose, comfortable clothing and leave jewelry at home. You may be asked to wear a gown. ... and send a signed report to your primary care or referring physician , who will discuss the results ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... minimize any potential discomfort. Some physicians prescribe an antibiotic prior to and/or after the procedure. You ... page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers top of page This page ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... are also captured and stored electronically on a computer. Until recently, x-ray images were maintained on ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... a real-time form of x-ray called fluoroscopy to examine the uterus and fallopian tubes of ... uses a special form of x-ray called fluoroscopy and a contrast material . An x-ray (radiograph) ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... the area being examined by making it appear dark (or by electronically reversing the image contrast to ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... a large photographic negative). Today, most images are digital files that are stored electronically. These stored images ... ACR and RSNA are not responsible for the content contained on the web pages found at these ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... lies. top of page How does the procedure work? X-rays are a form of radiation like ... also be minimal and not long lasting. Most women experience vaginal spotting for a few days after ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... you have any signs of pelvic infection or pelvic inflammatory disease. You will be asked to remove some of ... radiation dose. In the event of a chronic inflammatory condition, pelvic infection or untreated sexually transmitted disease, be certain to notify the physician or technologist ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... ray technique that makes it possible to see internal organs in motion. During a hysterosalpingogram, the uterus ... possible for the physician to view joints or internal organs in motion. Still images or movies are ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... implant in the uterus. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic ... Send us your feedback Did you find the information you were looking for? Yes No Please type ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed regularly by a physician with expertise ... not responsible for the content contained on the web pages found at these links. About Us | Contact Us | ...

  7. Hysterosalpingography

    Science.gov (United States)

    ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed regularly by a physician with expertise ... not responsible for the content contained on the web pages found at these links. About Us | Contact Us | ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... Share your patient story here Related Articles and Media Sonohysterography Uterine Fibroid Embolization (UFE) Radiation Dose in X-Ray and CT Exams Contrast Materials Abnormal Vaginal Bleeding Cervical Cancer Endometrial Cancer ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available ... American College of Radiology (ACR) and the Radiological Society of North America (RSNA), comprising physicians with expertise ... of Use | Links | Site Map Copyright © 2018 Radiological Society of North America, Inc. (RSNA). To help ensure ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... uterus and fallopian tubes are filled with a water-soluble contrast material and the radiologist is able ... or over-the-counter medication to minimize any potential discomfort. Some physicians prescribe an antibiotic prior to ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... frequently compared to current x-ray images for diagnosis and disease management. top of page How is ... to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. The effective radiation dose ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Fluoroscopy ... lowest radiation dose possible while producing the best images for evaluation. ... body not being imaged receive minimal radiation exposure. top ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ... dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, allergies and medications you’re taking. This ... material . An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... about radiology? Share your patient story here Related Articles and Media ... note RadiologyInfo.org is not a medical facility. Please contact your physician with specific medical ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... Radiology (ACR) and the Radiological Society of North America (RSNA), comprising physicians with expertise in several radiologic ... Site Map Copyright © 2018 Radiological Society of North America, Inc. (RSNA). To help ensure current and accurate ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Fluoroscopy ... Share your patient story here Related Articles and Media ... Sponsored by Please note RadiologyInfo. ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... of page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers top of page This page was reviewed on February 10, 2018 Send us your feedback Did you find the information you were looking for? Yes ... Fibroid Embolization (UFE) Radiation Dose in X-Ray and CT Exams Contrast ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... X-rays are a form of radiation like light or radio waves. X-rays pass through most objects, including the body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... care is taken during x-ray examinations to use the lowest radiation dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... of the abdominal cavity, causing generalized lower abdominal pain, but this should also be minimal and not ... to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. The effective radiation dose ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... of the abdominal cavity, causing generalized lower abdominal pain, but this should also be minimal and not ... usually have no side effects in the typical diagnostic range for this exam. Risks There is always ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... comfortable clothing and leave jewelry at home. You may be asked to wear a gown. What is ... procedure. On the night before the procedure, you may be asked to take a laxative or an ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... lies. top of page How does the procedure work? X-rays are a form of radiation like ... ovaries, wall of the uterus, and other pelvic structures may be evaluated with MRI or ultrasound. Infertility ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... page This page was reviewed on February 10, 2018 Send us your feedback Did you find the ... Privacy | Terms of Use | Links | Site Map Copyright © 2018 Radiological Society of North America, Inc. (RSNA). To ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... Please note RadiologyInfo.org is not a medical facility. Please contact your physician with specific medical questions ... your community, you can search the ACR-accredited facilities database . This website does not provide cost information. ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available Toggle navigation ... uses a real-time form of x-ray called fluoroscopy to examine the uterus and fallopian tubes of a woman who is having difficulty becoming pregnant. It’s also used ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... an active inflammatory condition. Tell your physician or technologist if you have a chronic pelvic infection or ... inflammatory condition. You should notify your physician or technologist if you have a chronic pelvic infection or ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... discuss any recent illnesses, medical conditions, allergies and medications you’re taking. This procedure should not be ... given a mild sedative or over-the-counter medication to minimize any potential discomfort. Some physicians prescribe ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit ... and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers top of page This page was reviewed on ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... form of medical imaging. Fluoroscopy is a special x-ray technique that makes it possible to see internal organs ... reversing the image contrast to white), this special x-ray technique makes it possible for the physician to view ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... any possibility that they are pregnant. Many imaging tests are not performed during pregnancy so as not to expose the fetus to ... See the Safety page for more information about pregnancy and x-rays. A Word About ... The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... 30 minutes. top of page What will I experience during and after the procedure? This exam should ... be minimal and not long lasting. Most women experience vaginal spotting for a few days after the ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... during and after the procedure? This exam should cause only minor discomfort. There may be slight discomfort ... valuable information on a variety of abnormalities that cause infertility or problems carrying a fetus to term. ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... pregnant and discuss any recent illnesses, medical conditions, allergies and medications you’re taking. This procedure should ... medications being taken and if there are any allergies, especially to iodinated contrast materials . Also inform your ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... uterus and fallopian tubes are filled with a water-soluble contrast material and the radiologist is able ... are sometimes the best way to see if treatment is working or if a finding is stable ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... examine the uterus and fallopian tubes of a woman who is having difficulty becoming pregnant. It’s also ... uterosalpingography, is an x-ray examination of a woman's uterus and fallopian tubes that uses a special ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... examination may also be necessary so that any change in a known abnormality can be monitored over ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... for more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is ... taking our brief survey: Survey Do you have a personal story about radiology? Share your patient story ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... The closure of the fallopian tubes in a sterilization procedure and a sterilization reversal The re-opening of the fallopian tubes following a sterilization or disease-related blockage top of page How ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... of page Who interprets the results and how do I get them? A radiologist , a physician specifically ... E-mail: Area code: Phone no: Thank you! Do you have a personal story about radiology? Share ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... 30 minutes. top of page What will I experience during and after the procedure? This exam should ... areas. Outside links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo. ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... suspended over a table on which the patient lies. top of page How does the procedure work? ... images for evaluation. National and international radiology protection organizations continually review and update the technique standards used ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... for more information about radiation dose. In the event of a chronic inflammatory condition, pelvic infection or ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... not responsible for the content contained on the web pages found at these links. About ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available ... uterus and fallopian tubes are filled with a water-soluble contrast material and the radiologist is able ... and send a signed report to your primary care or referring physician , who will discuss the results ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... sexually transmitted disease. Wear loose, comfortable clothing and leave jewelry at home. You may be asked to ... are sometimes the best way to see if treatment is working or if a finding is stable ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... sexually transmitted disease. Wear loose, comfortable clothing and leave jewelry at home. You may be asked to ... may also be asked to remove jewelry, removable dental appliances, eye glasses ... sometimes the best way to see if treatment is working or if a finding is stable ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... images for evaluation. National and international radiology protection organizations continually review and update the technique standards used ... ovaries, wall of the uterus, and other pelvic structures may be evaluated with MRI or ultrasound. Infertility ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... When used with a contrast material, which clearly defines the area being examined by making it appear ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... lies. top of page How does the procedure work? X-rays are a form of radiation like light or ... time. Follow-up examinations are sometimes the best way to see if treatment is working or if a finding is stable or changed ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... page is reviewed regularly by a physician with expertise in the medical area presented and is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of North ... with expertise in several radiologic areas. Outside links: For the ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... any scarring within the uterine or peritoneal (abdominal) cavity . The procedure can be used to investigate repeated ... contrast material then begins to fill the uterine cavity , fallopian tubes and peritoneal cavity through the catheter ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... the oldest and most frequently used form of medical imaging. Fluoroscopy is a special x-ray technique that ... a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... slight chance of cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. The effective radiation dose for this procedure varies. See the Safety ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... standards used by radiology professionals. Modern x-ray systems have very ... and Resources RTAnswers.org Radiation Therapy for Gynecologic ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... of x-ray called fluoroscopy and a contrast material . An x-ray (radiograph) is a noninvasive medical ... tubes are filled with a water-soluble contrast material and the radiologist is able to use fluoroscopy ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... or suggestion into the following text box: Comment: E-mail: Area code: Phone no: Thank you! Please ... Recommend RadiologyInfo to a friend Send to (friend's e-mail address): From (your name): Your e-mail ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... radiation dose for this procedure varies. See the Safety page for more information about radiation dose. In ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... chronic pelvic infection or an untreated sexually transmitted disease. Wear loose, comfortable clothing and leave jewelry at ...

  6. Radiation dose and risk assessment in hysterosalpingography

    Directory of Open Access Journals (Sweden)

    Plećaš Darko V.

    2010-01-01

    Full Text Available Hysterosalpingography is an important diagnostic method for the evaluation of the female reproductive tract involving the exposure of patients to ionizing radiation. The irradiation of ovaries is unavoidable and radiation exposure of the patient and the associated radiological risk for the foetus and born child during the period of growth should be considered, as well. The purpose of this work is to evaluate organ and patient doses and radiation risks during hysterosalpingography procedures performed in a dedicated gynecological hospital. The entrance surface air kerma was measured for a total of 31 patients during hysterosalpingography. Based on the results obtained, the radiogenic risk for hereditary effects and cancer induction was estimated. The patient dose levels are in the range of 3-15 mGy, with a median value of 10 mGy, in terms of entrance surface air kerma. Estimated median ovarian and uterus doses are 1.7 and 2.3 mGy, respectively. The risk for fatal cancer and hereditary effects is estimated to be 5.5×10-5 and 3.4 ×10-6, respectively. Although low compared to the natural incidence of genetic effects and cancer, it can be elevated in cases of prolonged or repeated procedures or procedures where the non-optimized protocol is used.

  7. X-ray computed tomography for virtually unrolling damaged papyri

    Energy Technology Data Exchange (ETDEWEB)

    Allegra, Dario; Ciliberto, Paolo; Stanco, Filippo [Universita degli Studi di Catania, Dipartimento di Matematica ed Informatica, Catania (Italy); Ciliberto, Enrico [Universita degli Studi di Catania, Dipartimento di Scienze Chimiche, Catania (Italy); Petrillo, Giuseppe; Trombatore, Claudia [Universita degli Studi di Catania, Dipartimento di Scienze Mediche Chirurgiche e Tecnologie Avanzate, Catania (Italy)

    2016-03-15

    The regular format for ancient works of literature was the papyrus roll. Recently many efforts to perform virtual restoration of this archeological artifact have been done. In fact the case of ancient rolled papyrus is very intriguing. Old papyruses are the substrates of very important historical information, probably being the use of papyrus dated to the Pre-Dynastic Period. Papyrus degradation is often very hard so that physical unrolling is sometime absolutely impossible. In this paper, authors describe their effort in setting a new virtual restoration methodology based on software manipulation of X-ray tomographic images. A realistic model, obtained by painting a hieroglyph inscription of Thutmosis III on a papyrus substrate made by the original method described by Plinius the Elder and by pigments and binders compatible with the Egyptian use (ochers with natural glue), was made for the X-ray investigation. A GE Optima 660 64 slice was used to obtain a stack of tomographic slices of the rolled model. Each slice appears as spiral. The intensity variations along the cross-sectional result from ink on the papyrus. The files were elaborated with original software, written by the use of MATLAB high-level language, and the final result was quite similar to the radiography of the physically unrolled sheet. (orig.)

  8. X-ray computed tomography for virtually unrolling damaged papyri

    Science.gov (United States)

    Allegra, Dario; Ciliberto, Enrico; Ciliberto, Paolo; Petrillo, Giuseppe; Stanco, Filippo; Trombatore, Claudia

    2016-03-01

    The regular format for ancient works of literature was the papyrus roll. Recently many efforts to perform virtual restoration of this archeological artifact have been done. In fact the case of ancient rolled papyrus is very intriguing. Old papyruses are the substrates of very important historical information, probably being the use of papyrus dated to the Pre-Dynastic Period. Papyrus degradation is often very hard so that physical unrolling is sometime absolutely impossible. In this paper, authors describe their effort in setting a new virtual restoration methodology based on software manipulation of X-ray tomographic images. A realistic model, obtained by painting a hieroglyph inscription of Thutmosis III on a papyrus substrate made by the original method described by Plinius the Elder and by pigments and binders compatible with the Egyptian use (ochers with natural glue), was made for the X-ray investigation. A GE Optima 660 64 slice was used to obtain a stack of tomographic slices of the rolled model. Each slice appears as spiral. The intensity variations along the cross-sectional result from ink on the papyrus. The files were elaborated with original software, written by the use of MATLAB high-level language, and the final result was quite similar to the radiography of the physically unrolled sheet.

  9. Comparison of hysterosalpingography and laparoscopy in predicting fertility outcome

    NARCIS (Netherlands)

    Mol, B. W.; Collins, J. A.; Burrows, E. A.; van der Veen, F.; Bossuyt, P. M.

    1999-01-01

    In this study, we compare the prognostic significance of hysterosalpingography (HSG) and laparoscopy for fertility outcome. In a prospective cohort study in 11 clinics participating in the Canadian Infertility Treatment Evaluation Study (CITES), consecutive couples who registered between 1 April

  10. Hysterosalpingography and laparoscopy in infertile women

    International Nuclear Information System (INIS)

    Konarzewska, J.; Bianek-Bodzak, A.; Mielcarek, P.; Kobierski, J.

    2009-01-01

    Background: Despite dynamic development of diagnostic imaging methods and endoscopic procedures, X-ray hysterosalpingography remains the basic diagnostic procedure when anatomical cause of infertility is suspected. The aim of the study was to assess the correlation between HSG results and laparoscopy findings, especially in infertile women with normal results of hysterosalpingography. Material/Methods: The results of HSG and laparoscopies performed between 2002 and 2005 years in 53 infertile women were analyzed retrospectively. The indication for HSG was primary infertility in 44 cases and secondary infertility in 9 cases.Results: The result of HSG was normal in 51%. Pathological findings were observed in 49% of HSG and in 93% of laparoscopies. The most common pathological findings observed during laparoscopy were tubal occlusion (26% cases) and endometriosis (25% cases). Polycystic ovaries and myomas were observed in 20% of the performed laparoscopies. HSG and laparoscopy yield consistent results in evaluation of tubal patency (p < 0.001). Conclusions: HSG remains the method of first choice in the diagnostics of uterine malformations and tubal diseases as causes of infertility. When mechanical factors of female infertility are suspected, HSG allows the optimal choice of more invasive procedure. (authors)

  11. The geometrical precision of virtual bone models derived from clinical computed tomography data for forensic anthropology.

    Science.gov (United States)

    Colman, Kerri L; Dobbe, Johannes G G; Stull, Kyra E; Ruijter, Jan M; Oostra, Roelof-Jan; van Rijn, Rick R; van der Merwe, Alie E; de Boer, Hans H; Streekstra, Geert J

    2017-07-01

    Almost all European countries lack contemporary skeletal collections for the development and validation of forensic anthropological methods. Furthermore, legal, ethical and practical considerations hinder the development of skeletal collections. A virtual skeletal database derived from clinical computed tomography (CT) scans provides a potential solution. However, clinical CT scans are typically generated with varying settings. This study investigates the effects of image segmentation and varying imaging conditions on the precision of virtual modelled pelves. An adult human cadaver was scanned using varying imaging conditions, such as scanner type and standard patient scanning protocol, slice thickness and exposure level. The pelvis was segmented from the various CT images resulting in virtually modelled pelves. The precision of the virtual modelling was determined per polygon mesh point. The fraction of mesh points resulting in point-to-point distance variations of 2 mm or less (95% confidence interval (CI)) was reported. Colour mapping was used to visualise modelling variability. At almost all (>97%) locations across the pelvis, the point-to-point distance variation is less than 2 mm (CI = 95%). In >91% of the locations, the point-to-point distance variation was less than 1 mm (CI = 95%). This indicates that the geometric variability of the virtual pelvis as a result of segmentation and imaging conditions rarely exceeds the generally accepted linear error of 2 mm. Colour mapping shows that areas with large variability are predominantly joint surfaces. Therefore, results indicate that segmented bone elements from patient-derived CT scans are a sufficiently precise source for creating a virtual skeletal database.

  12. Virtual casting of stab wounds in cartilage using micro-computed tomography.

    Science.gov (United States)

    Pounder, Derrick J; Sim, Louise J

    2011-06-01

    In homicidal stabbings using a serrated knife, stab wounds involving costal cartilage leave striations on the cut surface of the cartilage from the serration points on the blade edge. Class characteristics of the serrated blade can be determined from the striation marks, and individualizing characteristics may be seen also. The traditional method for recording the striation marks involves the pernickety technique of casting with dental impression material. We assessed the potential utility of micro-computed tomography scanning of the stab track as a technique for nondestructive recording of striation patterns and virtual casting of them. Stab tracks in porcine cartilage, produced with a coarsely serrated blade, were scanned with a bench-top micro-computed tomography scanner. The typical irregularly regular striation pattern could be demonstrated, and the images manipulated, using proprietary software to produce a virtual cast. Whether the technology will have sufficient resolution to image not only class characteristic tool marks but also the much finer individualizing tool marks remains to be evaluated, but the technology shows considerable promise.

  13. Head and neck computed tomography virtual endoscopy: evaluation of a new imaging technique.

    Science.gov (United States)

    Gallivan, R P; Nguyen, T H; Armstrong, W B

    1999-10-01

    To evaluate a new radiographic imaging technique: computed tomography virtual endoscopy (CTVE) for head and neck tumors. Twenty-one patients presenting with head and neck masses who underwent axial computed tomography (CT) scan with contrast were evaluated by CTVE. Comparisons were made with video-recorded images and operative records to evaluate the potential utility of this new imaging technique. Twenty-one patients with aerodigestive head and neck tumors were evaluated by CTVE. One patient had a nasal cylindrical cell papilloma; the remainder, squamous cell carcinomas distributed throughout the upper aerodigestive tract. Patients underwent complete head and neck examination, flexible laryngoscopy, axial CT with contrast, CTVE, and in most cases, operative endoscopy. Available clinical and radiographic evaluations were compared and correlated to CTVE findings. CTVE accurately demonstrated abnormalities caused by intraluminal tumor, but where there was apposition of normal tissue against tumor, inaccurate depictions of surface contour occurred. Contour resolution was limited, and mucosal irregularity could not be defined. There was very good overall correlation between virtual images, flexible laryngoscopic findings, rigid endoscopy, and operative evaluation in cases where oncological resections were performed. CTVE appears to be most accurate in evaluation of subglottic and nasopharyngeal anatomy in our series of patients. CTVE is a new radiographic technique that provides surface-contour details. The technique is undergoing rapid technical evolution, and although the image quality is limited in situations where there is apposition of tissue folds, there are a number of potential applications for this new imaging technique.

  14. Hysterosalpingography: Still relevant in the evaluation of infertility in ...

    African Journals Online (AJOL)

    ... uterine synechia 26(19.0%) and bi-cornuate uterus in 1(0.7%). Conclusion: HSG is relevant in the investigation of infertile women. Bilateral tubal occlusion from pelvic inflammatory disease, puerperal sepsis and unsafe abortions remains a major challenge in the Niger delta. Key words: Hysterosalpingography, infertility, ...

  15. Structural findings at hysterosalpingography in patients with infertility ...

    African Journals Online (AJOL)

    Materials and Methods: A retrospective review of 289 consecutive patients who underwent hysterosalpingography using ionic water-soluble contrast media was done at 2 private x-ray units in Kampala. Clinical notes and radiological findings were analysed for demographic data, uterine status, tubal and pelvic pathology.

  16. The hysterosalpingography examination verified by laparoscopy; Laparoskopowa weryfikacja obrazow histerosalpingograficznych

    Energy Technology Data Exchange (ETDEWEB)

    Popiela, A.; Kasiak, J.; Heimrath, T.; Cislo, M. [Akademia Medyczna, Wroclaw (Poland)

    1993-12-31

    The authors discuss 47 cases in which the hysterosalpingography (HSG) examination showed secondary tubar unpatency, then verified by laparoscopy. In the opinion of the authors supported by the results the HSG examination may be considered only as a preliminary element of tubar patency examination. In case of planned microsurgery the only qualifying or disqualifying examination is the laparoscopy with introduction of color contrast. (author)

  17. Estimation of effective dose during hysterosalpingography procedures

    International Nuclear Information System (INIS)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M.; Sulieman, A.; Alsafi, K.; Omer, H.

    2014-08-01

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  18. Virtual bronchoscopy using image data sets from positron-emission-tomography and computed-tomography; Virtuelle Bronchoskopie mit Positronenemissions- und Computertomographie-Bilddaten

    Energy Technology Data Exchange (ETDEWEB)

    Englmeier, K.H.; Jovanovic, A.; Muehling, M.; Seemann, M.D. [Nuklearmedizinische Klinik und Poliklinik, rechts der Isar, Technische Univ. Muenchen (DE). Inst. fuer Medizinische Informatik (Germany)

    2006-07-01

    Cancer is the second leading cause of death in the western world. Early diagnosis and targeted therapy provide the basis for planning effective treatment. Diseases like cancer generally begin with alterations at the molecular level. When the number of affected cells reaches the threshold for anatomical change, the disease can already be so advanced that it is too late for successful treatment. Equally, morphological change is not necessarily associated with malignancy. Diagnosis and staging of cancer, and evaluation of therapeutic success, depend today to a large extent on imaging techniques like computed tomography (CT) and magnetic resonance tomography (MRT). However, these can only be used to identify anatomical changes in lesions. Increasingly, imaging techniques like positron emission tomography (PET) are used that are based at the molecular level. Functional imaging techniques detect functional changes in tissues that play a role in the diagnosis and staging of the disease. Virtual reality techniques, especially virtual endoscopy, have also become more important in PET-CT diagnostics. On the one hand, these methods enable simultaneous visualisation of morphological and metabolic relationships; on the other hand, the enormous amount of image data from PET-CT can be made understandable in an intuitive form with the aid of endoluminal three-dimensional (3-D) images and scenes. The prerequisite is that the image data from PET and CT are segmented after fusion using image analysis techniques and subsequently projected using a 3-D imaging system and virtual reality techniques. Together with the Department of Nuclear Medicine of the Technical University, Munich, a system has been developed for virtual bronchoscopy that is intended to improve diagnostic precision in cases of bronchial carcinoma. (orig.)

  19. [Potentialities of virtual colonoscopy multispiral computed tomography in the diagnosis of colon pathology].

    Science.gov (United States)

    Khomutova, E Iu

    2012-01-01

    The trial enrolled 626 patients aged 2 to 82 years (mean age 47 +/- 3,2 years), including 548 patients with tumors (adenomatous polyps and carcinoma) of the colon and 78 with its inflammatory diseases (ulcerative colitis and Crohn's disease). Among them there were 330 men and 296 women. All the patients gave their consent for virtual colonoscopy (VC). They all also underwent endoscopic colonoscopy. The minimum size of a detected polyp on VC multispiral computed tomography (MSCT) scans was 4 mm in diameter. The study showed that VC MSCT had a high sensitivity in detecting various colon diseases, particularly 93% sensitivity in identifying space-occupying lesions, comfortability for the patient compared to endoscopic colonoscopy and irrigoscopy, and a rather high capacity and a low radiation load (compared to irrigoscopy). The quality of examination during VC MSCT depends on how the patient has been prepared (the most complete colon cleansing before the examination). A complete set of postprocedure processes of images should be used to improve the quality of examination. The exclusive prerogative of VC MSCT is to study the thickness of the wall and its lesion extent and to evaluate pericolitic changes, the lymphatic apparatus and mesentery, and in parallel with abdominal parenchymatous organs. This procedure is especially indicated for incomplete or contraindicative endoscopic colonoscopy, examination of the parietal segments of the colon in children to detect developmental malformations.

  20. Laboratory-based x-ray phase-contrast tomography enables 3D virtual histology

    Science.gov (United States)

    Töpperwien, Mareike; Krenkel, Martin; Quade, Felix; Salditt, Tim

    2016-09-01

    Due to the large penetration depth and small wavelength hard x-rays offer a unique potential for 3D biomedical and biological imaging, combining capabilities of high resolution and large sample volume. However, in classical absorption-based computed tomography, soft tissue only shows a weak contrast, limiting the actual resolution. With the advent of phase-contrast methods, the much stronger phase shift induced by the sample can now be exploited. For high resolution, free space propagation behind the sample is particularly well suited to make the phase shift visible. Contrast formation is based on the self-interference of the transmitted beam, resulting in object-induced intensity modulations in the detector plane. As this method requires a sufficiently high degree of spatial coherence, it was since long perceived as a synchrotron-based imaging technique. In this contribution we show that by combination of high brightness liquid-metal jet microfocus sources and suitable sample preparation techniques, as well as optimized geometry, detection and phase retrieval, excellent three-dimensional image quality can be obtained, revealing the anatomy of a cobweb spider in high detail. This opens up new opportunities for 3D virtual histology of small organisms. Importantly, the image quality is finally augmented to a level accessible to automatic 3D segmentation.

  1. Characterizing root system characteristics with Electrical resistivity Tomography: a virtual rhizotron simulation

    Science.gov (United States)

    Rao, Sathyanarayan; Ehosioke, Solomon; Lesparre, Nolwenn; Nguyen, Frédéric; Javaux, Mathieu

    2017-04-01

    Electrical Resistivity Tomography (ERT) is more and more used for monitoring soil water content in a cropped soil. Yet, the impact of roots on the signal is often neglected and a topic of controversy. In several studies related to soil-root system, it has been showed that the measured root mass density statistically correlates with the electrical conductivity (EC) data obtained from ERT. In addition, some studies suggest that some roots are more electrically conductive than soil for most water content. Thus, higher EC of roots suggest that it might have a measurable impact on ERT signals. In this work, virtual rhizotrons are simulated using the software package called R-SWMS that solves water and solute transport in plant root-soil system, including root growth. The distribution of water content obtained from R-SWMS simulation is converted into EC data using pedo-physical models. The electrical properties of roots and rhizosphere are explicitly included in the EC data to form a conductivity map (CM) with a very detailed spatial resolution. Forward ERT simulations is then carried out for CM generated for various root architectures and soil conditions to study the impact of roots on ERT forward (current and voltage patterns) and inverse solutions. It is demonstrated that under typical injection schemes with lateral electrodes, root system is hardly measurable. However, it is showed that adding electrodes and constraints on the ERT inversion based on root architecture help quantifying root system mass and extent.

  2. Pericaval venous intravasation in the changed indication of hysterosalpingography

    Energy Technology Data Exchange (ETDEWEB)

    Gowin, W.; Fuchs, P.

    1984-01-01

    Today the indication of hysterosalpingography is supplied via radiography in the diagnosis of female infertility patients. Hence, a different group of patients is now selected in contrast to the previous indications. The venous intravasation in uterine and adnexial vessels among infertility patients was observed in only 0.4% of our cases. The relationship between the changed indication, the technique of HSG, the changed permeability of the vessels after surgery, and the rare occurrence of intravasation is discussed.

  3. The use of cone-beam computed tomography and virtual reality simulation for pre-surgical practice in endodontic microsurgery.

    Science.gov (United States)

    Suebnukarn, S; Rhienmora, P; Haddawy, P

    2012-07-01

    To design and evaluate the impact of virtual reality (VR) pre-surgical practice on the performance of actual endodontic microsurgery.   The VR system operates on a laptop with a 1.6-GHz Intel processor and 2 GB of main memory. Volumetric cone-beam computed tomography (CBCT) data were acquired from a fresh cadaveric porcine mandible prior to endodontic microsurgery. Ten inexperienced endodontic trainees were randomized as to whether they performed endodontic microsurgery with or without virtual pre-surgical practice. The VR simulator has microinstruments to perform surgical procedures under magnification. After the initial endodontic microsurgery, all participants served as their own controls by performing another procedure with or without virtual pre-surgical practice. All procedures were videotaped and assessed by two independent observers using an endodontic competency rating scale (from 6 to 30). A significant difference was observed between the scores for endodontic microsurgery on molar teeth completed with virtual pre-surgical practice and those completed without virtual presurgical practice, median 24.5 (range = 17-28) versus median 18.75 (range = 14-26.5), P = 0.041. A significant difference was observed between the scores for osteotomy on a molar tooth completed with virtual pre-surgical practice and those completed without virtual pre-surgical practice, median 4.5 (range = 3.5-4.5) versus median 3 (range = 2-4), P = 0.042. Pre-surgical practice in a virtual environment using the 3D computerized model generated from the original CBCT image data improved endodontic microsurgery performance. © 2012 International Endodontic Journal.

  4. Laparoscopy comparison to hysterosalpingography in infertile women; Porownanie histerosalpingografii i laparoskopii u nieplodnych kobiet

    Energy Technology Data Exchange (ETDEWEB)

    Micinski, P.; Poreba, R.; Smoczynska, W. [Slaska Akademia Medyczna, Tychy (Poland)

    1993-12-31

    A diagnostic laparoscopy was performed in 57 unexplained infertility patients with apparently normal hysterosalpingography pictures. Despite it, laparoscopy revealed 51% pathologic changes of reproductive organs in pelvis minor. (author) 13 refs, 3 tabs

  5. Comparison of hysterosalpingoscintigraphy and hysterosalpingography for evaluation of tubal patency

    International Nuclear Information System (INIS)

    Wuerfel, W.; Steck, T.; Albert, P.; Becker, W.; Weppler, M.; Beckmann, M.

    1990-01-01

    This paper compares hysterosal pingoscintigraphy (HSS) with hysterosalpingography (HSG) in women with tubal occlusion or idiopathic sterility. Before HSS, HSG was performed. During ovulation period, we injected 8-10 MBq of Tc-9mm-labeled human albumin macroaggregates (HAMA) suspended in 2 mL of 9.9 mL saline into the posterior vaginal fornix. Gamma camera images (preset at 50,000 counts; anteroposterior projection) were obtained at 10, 60, and 150 minutes after injection. The authors examined 44 patients, 20 with idopathic sterility and 24 with tubal blockage. Activity could be demonstrated in fallopian tubes between 10 and 100 minutes

  6. Extension and Spatial Distribution of Atherosclerotic Burden Using Virtual Monochromatic Imaging Derived From Dual-energy Computed Tomography.

    Science.gov (United States)

    Rodríguez-Granillo, Gastón A; Carrascosa, Patricia; Deviggiano, Alejandro; Capunay, Carlos; de Zan, Macarena C; Goldsmit, Alejandro

    2016-10-01

    We explored the differences between atherosclerotic burden with invasive coronary angiography and virtual monochromatic imaging derived from dual-energy computed tomography coronary angiography. Eighty consecutive patients referred for invasive coronary angiography underwent dual-energy computed tomography coronary angiography and were categorized according to the atherosclerotic burden extent using the modified Duke prognostic coronary artery disease index, coronary artery disease extension score, segment involvement score, and the segment stenosis score. The mean segment involvement score (8.2 ± 3.9 vs 6.0 ± 3.7; P < .0001), modified Duke index (4.33 ± 1.6 vs 4.0 ± 1.7; P = .003), coronary artery disease extension score (4.84 ± 1.8 vs 4.43 ± 2.1; P = .005), and the median segment stenosis score (13.5 [9.0-18.0] vs 9.5 [5.0-15.0]; P < .0001) were significantly higher on dual-energy computed tomography compared with invasive angiography. Dual-energy computed tomography showed a significantly higher number of patients with any left main coronary artery lesion (46 [58%] vs 18 [23%]; P < .0001) and with severe proximal lesions (0.28 ± 0.03 vs 0.26 ± 0.03; P < .0001) than invasive angiography. Levels of coronary artery calcification below and above the median showed a sensitivity, specificity, positive predictive value, and negative predictive value of 100% and 97%; 86% and 50%; 93% and 95%; 100% and 67% for the identification of ≥ 50% stenosis. Dual-energy computed tomography coronary angiography identified a significantly larger atherosclerotic burden compared with invasive coronary angiography, particularly involving the proximal segments. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  7. Image Guided Virtual Autopsy: An Adjunct with Radiographic and Computed Tomography Modalities - An Important Tool in Forensic Identification

    Directory of Open Access Journals (Sweden)

    Shalu Rai

    2017-01-01

    Full Text Available The forensic examination of dead bodies is very helpful in order to identify the person, cause of death, gender, and solving the mysterious cases. It includes a number of techniques, out of which autopsy is the primary investigation that is performed in every medicolegal case. Because of mutilation technologies, traditional autopsy technique is most disturbing in terms of emotions and rituals of relatives. The use of radiology in forensic science comprises performance, interpretation, and reporting of radiographs that is helpful in detecting those changes that are not clinically visible. Forensic radiology plays an important role for identification of humans in mass disasters, criminal investigations, and evaluation of cause of death. The introduction of radiological modalities in autopsy techniques is a complementary tool for forensic identification and is known as virtual autopsy. The advance imaging techniques such as computed tomography (CT and magnetic resonance imaging (MRI is used in virtual autopsy in order to visualize and reconstruct the internal organs to know the site, type, and depth of injury. This review elaborates the role of maxillofacial imaging in image-guided virtual autopsy.

  8. The geometrical precision of virtual bone models derived from clinical computed tomography data for forensic anthropology

    NARCIS (Netherlands)

    Colman, Kerri L.; Dobbe, Johannes G. G.; Stull, Kyra E.; Ruijter, Jan M.; Oostra, Roelof-Jan; van Rijn, Rick R.; van der Merwe, Alie E.; de Boer, Hans H.; Streekstra, Geert J.

    2017-01-01

    Almost all European countries lack contemporary skeletal collections for the development and validation of forensic anthropological methods. Furthermore, legal, ethical and practical considerations hinder the development of skeletal collections. A virtual skeletal database derived from clinical

  9. Optimizing window settings for improved presentation of virtual monoenergetic images in dual-energy computed tomography.

    Science.gov (United States)

    Fu, Wanyi; Marin, Daniele; Ramirez-Giraldo, Juan Carlos; Choudhury, Kingshuk Roy; Solomon, Justin; Schabel, Christoph; Patel, Bhavik N; Samei, Ehsan

    2017-11-01

    Dual-energy computed tomography virtual monoenergetic imaging (VMI) at 40 keV exhibits superior contrast-to-noise ratio (CNR), although practicing radiologists do not consistently prefer it over VMI at 70 keV due to high perceivable noise. We hypothesize that the presentation of 40 keV VMI may be compromised using window settings (i.e., window-and-level values [W-L values]) designed for conventional single-energy CT. This study aimed to devise optimum window settings that reduce the apparent noise and utilize the high CNR of 40 keV VMI, in order to improve the conspicuity of hypervascular liver lesions. Three W-L value adjustment methods were investigated to alter the presentation of 40 keV VMI. To harness the high CNR of 40 keV VMI, the methods were designed to achieve (a) liver histogram distribution, (b) lesion-to-liver contrast, or (c) liver background noise comparable to those perceived in 70 keV VMI. This IRB-approved study included 18 patient abdominal datasets reconstructed at 40 and 70 keV. For each patient, the W-L values were determined using the three methods. For each of the images with default or adjusted W-L values, the noise, contrast, and CNR were calculated in terms of both display space and native CT number (referred to as HU) space. An observer study was performed to compare the 40 keV images with the three adjusted W-L values, and 40 and 70 keV images with default W-L values in terms of noise, contrast, and diagnostic preference. A comparison was also made in terms of the applicability of using patient-specific or patient-averaged W-L values. Using the default W-L values, 40 keV VMI exhibited higher HU CNR than 70 keV VMI by 24.6 ± 14.9% (P histogram-, noise-, and contrast equalization methods, respectively. The 40 keV images with all three W-L value adjustment methods showed improved perceived conspicuity (CNR) of liver presentation by 103-120% (P histogram-equalized W-L values were the most preferred, followed by 40 keV images with contrast

  10. Tomography

    International Nuclear Information System (INIS)

    1985-01-01

    Already widely accepted in medicine, tomography can also be useful in industry. The theory behind tomography and a demonstration of the technique to inspect a motorcycle carburetor is presented. To demonstrate the potential of computer assisted tomography (CAT) to accurately locate defects in three dimensions, a sectioned 5 cm gate valve with a shrink cavity made visible by the sectioning was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +-1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  11. The use of a wax bite wafer and a double computed tomography scan procedure to obtain a three-dimensional augmented virtual skull model.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mommaerts, M.Y.; Abeloos, J.V.S.; Clercq, C. De; Lamoral, P.; Neyt, N.; Casselman, J.W.; Schutyser, F.A.C.

    2007-01-01

    A detailed visualization of the interocclusal relationship is essential in a three-dimensional virtual planning setup for orthognathic and facial orthomorphic surgery. The purpose of this study was to introduce and evaluate the use of a wax bite wafer in combination with a double computed tomography

  12. A cone-beam computed tomography triple scan procedure to obtain a three-dimensional augmented virtual skull model appropriate for orthognathic surgery planning.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mollemans, W.; Clercq, C. De; Abeloos, J.V.S.; Lamoral, P.; Lippens, F.R.C.; Neyt, N.; Casselman, J.W.; Schutyser, F.A.C.

    2009-01-01

    The aim of this study was to present a new approach to acquire a three-dimensional virtual skull model appropriate for orthognathic surgery planning without the use of plaster dental models and without deformation of the facial soft-tissue mask. A "triple" cone-beam computed tomography (CBCT) scan

  13. Evaluation of occupational radiation dose of extremities on hysterosalpingography

    International Nuclear Information System (INIS)

    Filipov, D.; Kotowski, S.T.A.

    2017-01-01

    In the Hysterosalpingography (HSG) exam there is always a professional present with their hands very close to the radiation field. Based on CNEN, individuals occupationally exposed to radiation have equivalent dose limit values for the extremities (500 mSv / year). The objective of the study was to verify the equivalent dose in the hand region of an IOE (Occupationally Exposed Individual) that performs the HSG test and to compare it with the CNEN limit and with similar studies. A humanoid phantom was used to simulate the patient and an ionization chamber, which was placed in the place commonly occupied by the professional. The equivalent hand dose result (∼ 30 mSv / year) equals 6% of the CNEN annual dose limit, but is close to most studies using fluoroscopes. Therefore, the optimization of radiological protection is necessary to reduce these results

  14. Therapeutic value of hysterosalpingography with Lipiodol ultra fluid

    International Nuclear Information System (INIS)

    Rasmussen, F.; Justesen, P.; Toenner Nielsen, D.

    1987-01-01

    Hysterosalpingography (HSG) with Lipiodol ultra fluid was performed in 294 infertile women with a normal ovulatory temperature curve and at least two years of infertility and a partner with normal sperm. In 21%, pregnancy occurred within 6 months after the examination, and about one third of the women with a normal finding or with intraperitoneal adhesions at HSG conceived. The pregnancy rate was especially high in the first two cycles after HSG. The spontaneous pregnancy rate was 8%, and the difference between this and the total number of pregnancies must be attributed to a therapeutic effect of the procedure. Previous pelvic inflammatory disease was present in 40% of those who did not become pregnant, while only 11% of those who conceived had previous inflammation. Of the women without previous gynecologic disease 30% conceived. (orig.)

  15. Therapeutic value of hysterosalpingography with Lipiodol ultra fluid

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, F.; Justesen, P.; Toenner Nielsen, D.

    Hysterosalpingography (HSG) with Lipiodol ultra fluid was performed in 294 infertile women with a normal ovulatory temperature curve and at least two years of infertility and a partner with normal sperm. In 21%, pregnancy occurred within 6 months after the examination, and about one third of the women with a normal finding or with intraperitoneal adhesions at HSG conceived. The pregnancy rate was especially high in the first two cycles after HSG. The spontaneous pregnancy rate was 8%, and the difference between this and the total number of pregnancies must be attributed to a therapeutic effect of the procedure. Previous pelvic inflammatory disease was present in 40% of those who did not become pregnant, while only 11% of those who conceived had previous inflammation. Of the women without previous gynecologic disease 30% conceived.

  16. Tomography

    International Nuclear Information System (INIS)

    Allan, C.J.; Keller, N.A.; Lupton, L.R.; Taylor, T.; Tonner, P.D.

    1984-10-01

    Tomography is a non-intrusive imaging technique being developed at CRNL as an industrial tool for generating quantitative cross-sectional density maps of objects. Of most interest is tomography's ability to: distinguish features within complex geometries where other NDT techniques fail because of the complexity of the geometry; detect/locate small density changes/defects within objects, e.g. void fraction measurements within thick-walled vessels, shrink cavities in castings, etc.; provide quantitative data that can be used in analyses, e.g. of complex processes, or fracture mechanics; and provide objective quantitative data that can be used for (computer-based) quality assurance decisions, thereby reducing and in some cases eliminating the present subjectivity often encountered in NDT. The CRNL program is reviewed and examples are presented to illustrate the potential and the limitations of the technology

  17. Micro-computed tomography scan and virtual histological slide data for the land planarian Obama otavioi (Platyhelminthes).

    Science.gov (United States)

    Carbayo, Fernando; Lenihan, Jennifer Winifred

    2016-01-01

    We investigated whether images obtained through X-ray micro-computed tomography (μCT) can be used in conjunction with traditional methods for morphological studies of soft-bodied land planarians. μCT is non-invasive and provides true-to-scale three-dimensional imagery at high resolution. We compared μCT-based images of a recently described land planarian species of Obama otavioi (Platyhelminthes) with those obtained from light microphotography of histological sections, most of which were also digitized at high magnification. The specimens studied were collected in 2012. Subsequent μCT-based images of the stained body of a paratype show nearly all morphological features provided by traditional histology, with the exception of particularly minute structures, smaller than 5 μm, such as the sensory pits and single muscle fibers, which are best visible on traditional histological sections. Because the technique is non-destructive, the scanned specimen is preserved without damage. The raw and derivative μCT data and virtual histological sections are freely available in GigaDB. The μCT datasets of these stained soft-bodied organisms reveal images of external and internal structures that support previous taxonomic studies. This technique can be particularly important for non-destructively revealing internal details of whole museum specimens at a faster rate than histology alone. High-resolution virtual histological slides also allow further searches for new, previously unstudied morphological features. The use of X-ray equipment with higher resolution can enable smaller sensory organ and muscle fiber details to be seen. The image sets, μCT-based images and digitized histological slides can be disseminated without the constraints of specimen loans.

  18. The accuracy of hysterosalpingography in the diagnosis of tubal pathology: a meta-analysis

    NARCIS (Netherlands)

    Swart, P.; Mol, B. W.; van der Veen, F.; van Beurden, M.; Redekop, W. K.; Bossuyt, P. M.

    1995-01-01

    OBJECTIVE: To assess the value of hysterosalpingography (HSG) in diagnosing tubal patency and peritubal adhesions using laparoscopy with chromopertubation as the gold standard. DESIGN: Meta-analysis of 20 studies comparing HSG and laparoscopy for tubal patency and peritubal adhesions. PATIENTS: Four

  19. Pain relief during hysterosalpingography: role of intracervical block.

    Science.gov (United States)

    Chauhan, Meenakshi B; Lakra, Pinkey; Jyotsna, Dehlan; Nanda, Smiti; Malhotra, Vani

    2013-01-01

    Hysterosalpingography (HSG) is an important tool for evaluation of tubal factors in infertility. It does not require anesthesia but can be a painful procedure. Thus, this study was undertaken to establish the role of intracervical block as pain relief modality for HSG. This prospective, randomized study included hundred women attending the Department of Obstetrics and Gynecology, at a tertiary care centre in India. They were divided randomly through a computer generated table into two groups of 50 women each. In the study group, women received intracervical block along with premedication whereas in the control group women received premedication alone. Each patient was asked to rate her pain at six different points of time (T1-T6) during HSG using Visual analogue scale (VAS) and Verbal descriptive score. The difference in pain scores amongst the two groups was analyzed using independent t test. Reduction of pain was observed from placement of tenaculum till end of procedure (T3-T6) with intracervical block (p Intracervical block can be offered to all women undergoing HSG to make the procedure less painful and thus improve the compliance.

  20. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    Energy Technology Data Exchange (ETDEWEB)

    Karakas, Hakki Muammer [Inonu University Medical Faculty, Turgut Ozal Medical Center, Department of Radiology, Malatya (Turkey); Celbis, Osman [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Forensic Medicine, Malatya (Turkey); Harma, Ahmet [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Orthopaedics and Traumatology, Malatya (Turkey); Alicioglu, Banu [Trakya University Medical Faculty, Department of Radiology, Edirne (Turkey); Trakya University Health Sciences Institute, Department of Anatomy, Edirne (Turkey)

    2011-05-15

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 {+-} 14.9 years) and 43 women (41.1 {+-} 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 {+-} 12.6 mm (77-138 mm) in men and 104.7 {+-} 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  1. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    International Nuclear Information System (INIS)

    Karakas, Hakki Muammer; Celbis, Osman; Harma, Ahmet; Alicioglu, Banu

    2011-01-01

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 ± 14.9 years) and 43 women (41.1 ± 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 ± 12.6 mm (77-138 mm) in men and 104.7 ± 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  2. Comparison of Virtual Dental Implant Planning Using the Full Cross-Sectional and Transaxial Capabilities of Cone Beam Computed Tomography vs Reformatted Panoramic Imaging and 3D Modeling.

    Science.gov (United States)

    Khan, Moiz; Elathamna, Eiad N; Lin, Wei-Shao; Harris, Bryan T; Farman, Allan G; Scheetz, James P; Morton, Dean; Scarfe, William C

    2015-01-01

    To compare the choice and placement of virtual dental implants in the posterior edentulous bounded regions using the full cross-sectional and transaxial capabilities of cone beam computed tomography (CBCT) vs reformatted panoramic images and three-dimensional (3D) virtual models. Fifty-two cases with posterior bounded edentulous regions (61 dental implant sites) were identified from a retrospective audit of 4,014 radiographic volumes. Two image sets were created from selected CBCT data: (1) a combination of reformatted panoramic imaging and a 3D model (PIref/3D), and (2) the full 3D power in CBCT image volume analyses (XS). One virtual implant was placed by consensus of three prosthodontists in each image set: PIref/3D and XS. The choice of implant length and the perceived need for ridge augmentation were recorded for implant placement in both test situations. All the virtual implant placements from both PIref/3D and XS image sets were inspected retrospectively using virtual 3D models, and the number of exposed threads on both the buccal and lingual/palatal aspects of the virtual dental implant was evaluated. The chi-square and paired t tests were used with the level of significance set at α = .05. Shorter implants were chosen more often using XS than PIref/3D (P = .001). Fewer threads were exposed when placed with XS than with PIref/3D (P = .001). The use of XS reduced the perceived need for ridge augmentation compared with PIref/3D (P = .001). The use of the full 3D power of CBCT (including cross-sectional images in all three orthagonal planes and transaxially) provides supplemental information that significantly changes the choice of virtual implant length and vertical position of the implant, and reduces the frequency of perceived need for ridge augmentation before implant placement.

  3. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography

    International Nuclear Information System (INIS)

    Lopes, Cintya Carolina Barbosa

    2006-04-01

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  4. Variables affecting immediate pain tolerance in X-ray hysterosalpingography.

    Science.gov (United States)

    Sohail, Saba

    2004-03-01

    To determine the variables, which affect pain tolerance in x-ray hysterosalpingography (HSG). Cross-sectional comparative study. Radiology departments of Civil and Bismillah Taqee Hospitals and Delhi Mercantile Medical Centre, Karachi from January 1999 to June 2003. The study included 250 patients who underwent x-ray HSG using small sized Leech Wilkinson cannula by the same radiologist. Informed verbal consent was obtained from all the patients. Pain was graded into tolerable and intolerable using a four-point visual analog scale (VAS) as well as the Pakistani coin scale after pre-medication with diclofenac (generic name). Standard procedures using day-light fluoroscopy was performed. Variables considered were age, indication of the procedure, type of infertility, whether primary or secondary, emotional state, motivation for investigation, presence or absence of cystocele, duration of procedure, type of contrast used, whether ionic or non-ionic, tubal patency and lastly the amount of contrast used in the procedure. Those patients having infection, cervical erosion, use of larger size of cannula and technical complications including excessive bleeding requiring the use of sanitary napkins and vascular intravasation were excluded. The obtained data was analyzed on SPSS version 10.0 using cross tabulation and Pearson's correlation coefficient. Significance was taken at p15 minutes) and the use of ionic contrast media were the variables significantly associated with intolerable pain during the procedure. Primary infertility, calm emotional state, self-motivation, absence of cystocele and short procedure duration were associated with good pain tolerance. The amount of contrast used and tubal patency status had no significant association. In the setting of base line pre-medication with diclofenac and minimal cervical trauma, amenorrhea, primary infertility, emotional state, self-motivation, procedure duration, and the presence or absence of cystocele significantly affect

  5. Difficulties in recruitment for a randomized controlled trial involving hysterosalpingography

    Directory of Open Access Journals (Sweden)

    Helmerhorst Frans M

    2006-06-01

    Full Text Available Abstract Background The usefulness of hysterosalpingography (HSG as routine investigation in the fertility work-up prior to laparoscopy and dye had been assessed in a randomized controlled trial. Recruiting subjects to the study was more difficult than anticipated. The objective of this study was to explore possible reasons for non-participation in the trial. Methods All newly referred subfertile women admitted to the Reproductive Medicine Clinic of Leiden University Medical Centre between 1 April 1997 and 31 December 1999, were eligible for the study. The reasons for non-participation were evaluated by scrutinizing the medical records. Results Out of 759 women, a total of 127 (17% agreed to participate in the trial. The most important reason for non-participation was because of exclusion criteria (73%. Other reasons were inattentive clinicians (3% and patient-associated reasons (24%. Patient refusal and indecisiveness to enroll in the study were the most common patient-associated reasons. The most frequently stated reason for trial refusal was reluctance to undergo laparoscopy and dye mainly due to issues related to anesthesia and scheduling of procedure. Conclusion Almost three-quarters of recruitment difficulties in this study were due to unavoidable reasons. To overcome the remaining avoidable reasons for non-participation, attention should be paid to appropriate instruction of the study protocol to the participating doctors and to provide adequate information, in layman's terms, to the patients. Reminding patients by notes or telephone calls for attending the clinic are helpful. It may be contingent upon tracing the reasons of clinicians and patients for non-participation to improve enrollment during a trial.

  6. Estimation of effective dose during hysterosalpingography procedures; Estimación de dosis efectiva durante los procedimientos hysterosalpingography

    Energy Technology Data Exchange (ETDEWEB)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M. [King Saud University, College of Applied Medical Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433, (Saudi Arabia); Sulieman, A. [Salman bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P. O. Box 422, Alkharj (Saudi Arabia); Alsafi, K. [King Abdulaziz University, Faculty of Medicine, Radiology Department, Jeddah 22254 (Saudi Arabia); Omer, H., E-mail: kalzimami@ksu.edu.sa [Dammam University, Faculty of Medicine, Dammam Khobar Coastal Rd, Khobar 31982 (Saudi Arabia)

    2014-08-15

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  7. The effect of music on the anxiety levels of patients undergoing hysterosalpingography

    International Nuclear Information System (INIS)

    Agwu, K.K.; Okoye, I.J.

    2007-01-01

    Objectives: To determine the effect of music on the anxiety levels of patients undergoing a hysterosalpingography procedure. Patients and methods: One hundred hysterosalpingography referrals were randomly assigned to either the experimental or control group. Music chosen earlier by the patients was played during the hysterosalpingography procedure for the experimental group. The control group was studied without music. Certain physiological parameters and the State-Trait Anxiety Inventory were used to assess the patients' anxiety levels before and during the investigation. Patient's willingness to have a repeat procedure, should it become necessary, was also assessed in both groups as a measure of acceptability of the investigation. The z-test was used to analyze the results for any statistically significant differences between the experimental and the control groups. Results: The blood pressure (BP) monitored during the procedure was reduced in 31 (62%) of the patients in the experimental group compared to their pre-investigation values. Reduction in the pulse rate (PR) in 28 (56%) of the patients was also noted in the experimental group. On the other hand, the blood pressure of 37 (74%) of the patients and the pulse rate of 32 (64%) patients in the control group were increased from their pre-investigation values. The physiological parameters in the experimental group were significantly lower than the values in the control group during the investigation (p < 0.05). A comparison of the State-Trait Anxiety Inventory scores taken before and during the procedure shows significantly lower scores for the experimental group compared to those for the control group (p < 0.05). More patients, 41 (82%) in the experimental group were also willing to have a repeat procedure compared to 16 (32%) patients in the control. Conclusion: Music reduces the physiological and cognitive responses of anxiety in patients undergoing hysterosalpingography and can be harnessed for clinical

  8. The effect of music on the anxiety levels of patients undergoing hysterosalpingography

    Energy Technology Data Exchange (ETDEWEB)

    Agwu, K.K. [Department of Medical Radiography and Radiological Sciences, Faculty of Health Sciences and Technology, University of Nigeria, Enugu Campus, Enugu (Nigeria)]. E-mail: kenagwu2000@yahoo.com; Okoye, I.J. [Department of Radiation Medicine, University of Nigeria Teaching Hospital, Enugu (Nigeria)

    2007-05-15

    Objectives: To determine the effect of music on the anxiety levels of patients undergoing a hysterosalpingography procedure. Patients and methods: One hundred hysterosalpingography referrals were randomly assigned to either the experimental or control group. Music chosen earlier by the patients was played during the hysterosalpingography procedure for the experimental group. The control group was studied without music. Certain physiological parameters and the State-Trait Anxiety Inventory were used to assess the patients' anxiety levels before and during the investigation. Patient's willingness to have a repeat procedure, should it become necessary, was also assessed in both groups as a measure of acceptability of the investigation. The z-test was used to analyze the results for any statistically significant differences between the experimental and the control groups. Results: The blood pressure (BP) monitored during the procedure was reduced in 31 (62%) of the patients in the experimental group compared to their pre-investigation values. Reduction in the pulse rate (PR) in 28 (56%) of the patients was also noted in the experimental group. On the other hand, the blood pressure of 37 (74%) of the patients and the pulse rate of 32 (64%) patients in the control group were increased from their pre-investigation values. The physiological parameters in the experimental group were significantly lower than the values in the control group during the investigation (p < 0.05). A comparison of the State-Trait Anxiety Inventory scores taken before and during the procedure shows significantly lower scores for the experimental group compared to those for the control group (p < 0.05). More patients, 41 (82%) in the experimental group were also willing to have a repeat procedure compared to 16 (32%) patients in the control. Conclusion: Music reduces the physiological and cognitive responses of anxiety in patients undergoing hysterosalpingography and can be harnessed for

  9. Simple improvement in the technique of hysterosalpingography achieving optimal imaging and avoiding possible complications

    International Nuclear Information System (INIS)

    Beyth, Y.; Navot, D.; Lax, E.

    1985-01-01

    A simple technique is reported in which oil-soluble contrast media (OSCM) are used with hysterosalpingography to investigate infertility in women due to uterine and tubal pathology. The advantages of OSCM as compared with water-soluble contrast media (WSCM) are described. Complications caused by intravasation of the OSCM into lymph vessels and veins are avoided by clearing the media at the end of the procedure. This also results in the immediate spread of the contrast media in the pelvic cavity with the result that delayed radiographs become superfluous and the radiation dose to the genitals is reduced. 4 references, 2 figures

  10. Is hysterosalpingography able to diagnose all uterine malformations correctly? A retrospective study

    International Nuclear Information System (INIS)

    Braun, Petra; Grau, Francisco Vercher; Pons, Raul Mut; Enguix, Daniel Perez

    2005-01-01

    Background: Muellerian duct anomalies are an uncommon but often a treatable cause of infertility. Material and methods: From January 2002 until November 2003, a total of 705 hysterosalpingographies were realised of which 658 were analysed retrospectively in order to determine the importance of uterine malformations in infertile and sterile patients. In ten cases, the results of hysterosalpingography were compared with hysteroscopy and laparoscopy. Results: The frequency of uterine malformations in infertile and sterile women was 10%. In this population, arcuate uterus (57.6%) was the most common malformation, followed by subseptate uterus (18.2%), uterus bicornis unicollis (10.6%), uterus bicornis bicollis (3.0%), septate uterus (6.1%), unicornuate uterus (3.0%) and unicornuate uterus with double vagina (1.5%). Discussion: Our bibliographic research confirmed that arcuate uterus is the most frequent congenital malformation, but in gestations it does not show a significantly reduced live birth rate. Nevertheless, the septate uterus presents an important decrease of live birth rate that can be improved significantly by doing hysteroscopic metroplasty. As this is a completely different surgical intervention compared to bicornuate uterus, a correct diagnosis is very important. Differentiation of these two malformations is quite difficult by hysterosalpingographic exploration, wherefore an additional exploration by means of endovaginal or three-dimensional ultrasound is recommended

  11. Is hysterosalpingography able to diagnose all uterine malformations correctly? A retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Petra; Grau, Francisco Vercher; Pons, Raul Mut; Enguix, Daniel Perez

    2005-02-01

    Background: Muellerian duct anomalies are an uncommon but often a treatable cause of infertility. Material and methods: From January 2002 until November 2003, a total of 705 hysterosalpingographies were realised of which 658 were analysed retrospectively in order to determine the importance of uterine malformations in infertile and sterile patients. In ten cases, the results of hysterosalpingography were compared with hysteroscopy and laparoscopy. Results: The frequency of uterine malformations in infertile and sterile women was 10%. In this population, arcuate uterus (57.6%) was the most common malformation, followed by subseptate uterus (18.2%), uterus bicornis unicollis (10.6%), uterus bicornis bicollis (3.0%), septate uterus (6.1%), unicornuate uterus (3.0%) and unicornuate uterus with double vagina (1.5%). Discussion: Our bibliographic research confirmed that arcuate uterus is the most frequent congenital malformation, but in gestations it does not show a significantly reduced live birth rate. Nevertheless, the septate uterus presents an important decrease of live birth rate that can be improved significantly by doing hysteroscopic metroplasty. As this is a completely different surgical intervention compared to bicornuate uterus, a correct diagnosis is very important. Differentiation of these two malformations is quite difficult by hysterosalpingographic exploration, wherefore an additional exploration by means of endovaginal or three-dimensional ultrasound is recommended.

  12. Estimate of worker and patient exposures and quality control in hysterosalpingography exams

    International Nuclear Information System (INIS)

    Rodrigues, Barbara Beatriz Dias

    2006-06-01

    Hysterosalpingography (HSG) is a relatively frequent radiological procedure, which is used to access and study the uterine cavity and the tubary permeability. The estimate of the radiation doses received by the patients, and of the associated risks, has become of great interest in recent years. The importance in evaluating the received doses becomes even higher when the gonads region is irradiated; as in the case of hysterosalpingography, where the patients are relatively young, existing a high probability of future pregnancy. In HSG procedure the physician stays beside the patient, being also exposed. The purpose of this study was to analyze, during HSG procedures, the exposition of patients, measuring the kerma-area (P K,A ) product by using an ionization chamber of big area, to evaluate the doses received by the radiologist using thermoluminescent dosemeters and to evaluate the quality of image by means of qualitative methods. The results gotten during the accompaniment of 86 examinations had been the following ones: the average P K,A was 706 ± 388 cGy.cm 2 , to an average exposition time of 2 ± 1 minutes. In order to optimize the exposure of patients and workers, the time of scopy and the number of images should be reduced, whenever it is possible. Due to the significant values of equivalent dose received by the lens, the use of plumbiferous eyeglasses is recommended. (author)

  13. Virtual Computed Tomography Colonography: Evaluation of 2D and Virtual 3D Image Quality of Sub-mSv Examinations Enabled by Third-generation Dual Source Scanner Featuring Tin Filtering.

    Science.gov (United States)

    Seuss, Hannes; Janka, Rolf; Hammon, Matthias; Cavallaro, Alexander; Uder, Michael; Dankerl, Peter

    2018-01-19

    To evaluate two- and three-dimensional (2D and 3D) image quality of sub-milliSievert (mSv) computed tomography (CT) colonography utilizing a third-generation dual source CT scanner featuring a tin filter. We retrospectively evaluated 26 consecutive patients who underwent third-generation dual source CT colonography, nine with the standard-dose clinical-scan protocol (SDP) and 17 with a low-dose protocol (LDP) featuring a tin filter. Radiation dose was evaluated by volume computed tomography dose index (CTDI vol ), dose length product (DLP), effective dose (E), and size-specific dose estimate. Objective image quality was evaluated utilizing signal-to-noise ratio (SNR) derived from standardized placed regions of interest on the transverse 2D images and the ratio of SNR/CTDI vol (normalized SNR). Two radiologists in consensus assessed subjective image quality of the virtual 3D images. There were no significant differences in subjective image quality (P = .661). All examinations were rated "excellent" or "good" for diagnostic confidence. The mean total for DLP/E was 143.4 ± 29.8 mGy/3.00 ± 0.40 mSv in the SDP and therefore significantly higher than in the LDP with 36.9 ± 8.7 mGy/0.75 ± 0.16 mSv (P source CT featuring a tin filter enables consistent sub-mSv colonography without substantially impairing image quality. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  14. Virtual cystoscopy, computed tomography urography and optical cystoscopy for the detection and follow-up for bladder cancer.

    Science.gov (United States)

    Ibáñez Muñoz, D; Quintana Martínez, I; Fernández Militino, A; Sánchez Zalabardo, D; Sarria Octavio de Toledo, L; Cozcolluela Cabrejas, R

    To evaluate the utility of virtual cystoscopy (VC) performed with CT urography in patients being studied under gross hematuria or patients being followed-up after a previous bladder cancer and compare the results with those obtained with gold standard technique (optical cystoscopy). Retrospective study of 117 patients who were referred for VC by the Urology Department between May 2014 and May 2015. Those patients presented with gross hematuria or they were previously treated patients from bladder cancer being followed up. These patients were evaluated with MDCT and virtual cystoscopy after distending the bladder with air. The results were compared with those obtained with optical cystoscopy which was performed no more than a week after. The global sensitivity and specificity of VC were 81,8 and 92,1%. Aditional findings detected in CT urography were an aortic dissection, urinary lithiasis and colonic metastasis. VC seems an useful technique in the diagnosis and follow-up for bladder cancer with a good correlation with OC. The main limitations are the impossibility of biopsy during the procedure and the detection of erythematous lesions. Collateral findings can be detected performed with CT urography although the high radiation exposure does not recommend their combined use. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Contrast-Enhanced Nanofocus X-Ray Computed Tomography Allows Virtual Three-Dimensional Histopathology and Morphometric Analysis of Osteoarthritis in Small Animal Models.

    Science.gov (United States)

    Kerckhofs, Greet; Sainz, Julie; Maréchal, Marina; Wevers, Martine; Van de Putte, Tom; Geris, Liesbet; Schrooten, Jan

    2014-01-01

    One of the early hallmarks of osteoarthritis (OA) is a progressive degeneration of the articular cartilage. Early diagnosis of OA-associated cartilage alterations would be beneficial for disease prevention and control, and for the development of disease-modifying treatments. However, early diagnosis is still hampered by a lack of quantifiable readouts in preclinical models. In this study, we have shown the potency of contrast-enhanced nanofocus x-ray computed tomography (CE-nanoCT) to be used for virtual 3-dimensional (3D) histopathology in established mouse models for OA, and we compared with standard histopathology. We showed the equivalence of CE-nanoCT images to histopathology for the modified Mankin scoring of the cartilage structure and quality. Additionally, a limited set of 3D cartilage characteristics measured by CE-nanoCT image analysis in a user-independent and semiautomatic manner, that is, average and maximum of the noncalcified cartilage thickness distribution and loss in glycosaminoglycans, was shown to be predictive for the cartilage quality and structure as can be evaluated by histopathological scoring through the use of an empirical model. We have shown that CE-nanoCT is a tool that allows virtual histopathology and 3D morphological quantification of multitissue systems, such as the chondro-osseous junction. It provides faster and more quantitative data on cartilage structure and quality compared with standard histopathology while eliminating user bias. CE-nanoCT thus should allow capturing subtle differences in cartilage characteristics, carefully mapping OA progression and, ultimately, asses the beneficial changes when testing a candidate disease-modifying treatment.

  16. Usefulness of Computed Tomography in pre-surgical evaluation of maxillo-facial pathology with rapid prototyping and surgical pre-planning by virtual reality

    International Nuclear Information System (INIS)

    Toso, Francesco; Zuiani, Chiara; Vergendo, Maurizio; Bazzocchi, Massimo; Salvo, Iolanda; Robiony, Massimo; Politi, Massimo

    2005-01-01

    Purpose. To validate a protocol for creating virtual models to be used in the construction of solid prototypes useful for the planning-simulation of maxillo-facial surgery, in particular for very complex anatomical and pathologic problems. To optimize communications between the radiology, engineering and surgical laboratories. Methods and materials. We studied 16 patients with different clinical problems of the maxillo-facial district. Exams were performed with multidetector computed tomography (MDCT) and single slice computed tomography (SDCT) with axial scans and collimation of 0.5-2 mm, and reconstruction interval of 1 mm. Subsequently we performed 2D multiplanar reconstructions and 3D volume-rendering reconstructions. We exported the DICOM images to the engineering laboratory, to recognize and isolate the bony structures by software. With these data the solid prototypes were generated using stereolitography. To date, surgery has been preformed on 12 patients after simulation of the procedure on the stereolitography model. Results. The solid prototypes constructed in the difficult cases were sufficiently detailed despite problems related to the artefacts generated by dental fillings and prostheses. In the remaining cases the MPR/3D images were sufficiently detailed for surgical planning. The surgical results were excellent in all patients who underwent surgery, and the surgeons were satisfied with the improvement in quality and the reduction in time required for the procedure. Conclusions. MDCT enables rapid prototyping using solid replication, which was very helpful in maxillofacial surgery, despite problems related to artifacts due to dental fillings and prosthesis within the acquisition field; solutions for this problem are work in progress. The protocol used for communication between the different laboratories was valid and reproducible [it

  17. Detection of significant stenosis in the left anterior descending artery by 'virtual myocardial perfusion' bolus tracking, 320 slice computed tomography.

    Science.gov (United States)

    Takaoka, Hiroyuki; Funabashi, Nobusada; Fujimoto, Yoshihide; Kobayashi, Yoshio

    2014-12-20

    We used bolus-tracking CT-images, which are usually used only to detect contrast-material in target organs for optimal-starting of acquisition, as virtual first pass myocardial perfusion images. Retrospective-analysis of 14 patients (10 male, 63 ± 10 years) diagnosed with ≥ 75% stenosis confined to left-anterior-descending-artery (LAD) (7 patients, Group-1) or insignificant stenosis of any coronary artery (7 patients Group-2) diagnosed using invasive-coronary-angiograms (ICA) and enhanced 320-slice-CT within 3-months and without incident between examinations. Bolus-tracking CT-images were acquired at mid-level left-ventricle (LV) until CT-attenuation of descending-aorta increased to 200 HU. We measured CT-attenuation (HU) in the LV anterior-wall (AW), the basal inter-ventricular-septum (BIVS), and LV basal lateral-wall (BLW) in end-systole using both bolus-tracking images and routine, enhanced, early-phase CT-images. In the bolus-tracking images, the Group-1 LV AW, BIVS, BLW CT-attenuation and ratio of LV AW CT attenuation to the average of BIVS and BLW were 36 ± 7HU, 62 ± 11HU, 58 ± 25HU, and 0.6 ± 0.1 respectively. In Group-2, they were 53 ± 14HU, 56 ± 9HU, 54 ± 15HU, and 1.0 ± 0.3 respectively. LV AW CT attenuation and the ratio of LV AW CT values to the average of BIVS and BLW, were significantly lower in Group-1 (both P BLW and without the need for drugs, exercise or additional radiation-exposure. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. The Value of Hysterosalpingography following Medical Treatment with Methotrexate for Ectopic Pregnancy

    Directory of Open Access Journals (Sweden)

    Emma Garcia Grau

    2011-01-01

    Full Text Available After an ectopic pregnancy (EP fertility decreases, mostly due to tubal factor. Hysterosalpingography (HSG is the most cost-effective tool for tubal patency assessment. Objective. To evaluate the usefulness of a HSG after a medical treatment for an EP, in order to counsel women on the most appropriate way to conceive future pregnancies. Methods. Between 1998 and 2008, 144 patients were submitted to medical treatment for an EP and performed HSG 3 months after the event. Results. 72.2% of normal HSG, 18.8% with unilateral obstruction, 6.3% tubal patency with defect, and 2.8% bilateral obstruction. Conclusion. Routine HSG following medical treatment for an EP does not seem necessary, as it does not change the initial management in 97.2% of the cases, but might be considered in selected risk cases, permitting timely referral of patients to in vitro fertilization.

  19. Radiation dose in hysterosalpingography: modern 100mm fluorography vs. full-scale radiography

    International Nuclear Information System (INIS)

    Seppaenen, S.; Lehtinen, E.; Holli, H.

    1978-01-01

    Radiation doses of modern 100 mm fluorography and full-scale radiography were compared experimentally and applied to hysterosalpingography. It was determined that 100 mm fluorography reduced the doses by 28 to 29 percent per exposure and 37 to 47 percent per examination compared with full-scale radiography performed with fast tungstate screens in identical conditions (70 to 80 kV, 400 mA). The dose during one minute of videofluoroscopy was equivalent to the doses produced by one exposure in full-scale filming and three to four exposures in 100 mm filming. Although electronic magnification in 100 mm fluorography increases the doses by two or threefold, these are still less than the doses in full-scale radiography

  20. A comparative study of hysterosalpingography and endoscopy/laparotomy in infertile patients

    International Nuclear Information System (INIS)

    Nielsen, D.T.; Rasmussen, F.; Justesen, P.

    1987-01-01

    A comparison of hysterosalpingography (HSG), using Lipiodol ultrafluid as contrast medium, with endoscopy/laparotomy in the evaluation of the tubal function in 124 infertile women is presented. There was agreement between the results of both methods in 73.4% of the patients. The false-negative rate was 2.4% and the false-positive rate was 8.9%. Complications in the form of intravasation were seen in three patients but none of them had any symptoms. The conception rate was 35% in the subgroup of patients with normal HSG. The authors recommended the continuous use of HSG in the overall evaluation of infertile patients. It is recommended to use oil-soluble contrast media because of its high diagnostic accuracy, low frequency of complications and its therapeutic advantages. (orig.)

  1. Does Computed Tomography-Based Virtual Colonoscopy Improve the Accuracy of Preoperative Assessment Based on Magnetic Resonance Imaging in Women Managed for Colorectal Endometriosis?

    Science.gov (United States)

    Mehedințu, Claudia; Brîndușe, Lăcrămioara Aurelia; Brătilă, Elvira; Monroc, Michele; Lemercier, Ebticem; Suaud, Olivier; Collet-Savoye, Cecile; Roman, Horace

    2018-01-31

    To evaluate whether combining computed tomography-based virtual colonoscopy (CTC) with magnetic resonance imaging (MRI) improves preoperative assessment of colorectal endometriosis. Retrospective study using prospectively recorded data (Canadian Task Force classification II-2). University tertiary referral center. Seventy-one women treated for colorectal endometriosis managed between June 2015 and May 2016. Patients included in our study underwent colorectal surgery for deep endometriosis infiltrating the rectum or the sigmoid colon and had preoperative assessment using MRI and CTC. To establish the correlation between preoperative and intraoperative findings, the concordance kappa index was used. Preoperative data provided by MRI, CTC, and a combination of both were compared with intraoperative findings. All 71 patients had a total of 105 endometriotic intestinal lesions intraoperatively confirmed. Some 71.2% of rectal nodules and 60.0% of sigmoid nodules infiltrated the muscularis propria of the intestinal wall, with most infiltrating between 25% and 50% of the rectal circumference; 73% of rectal nodules and 96% of sigmoid nodules led to varying degrees of stenosis. The concordance between intraoperative and preoperative findings concerning the presence of rectal nodules was high, at .88 when associating CTC with MRI, whereas each imaging technique taken individually provided lower concordance coefficients. In our study 80.3% of patients underwent the procedure that had been preoperatively planned. Our study suggests that associating MRI with CTC leads to improved accuracy in preoperative assessment of colorectal endometriosis and in subsequent preoperative choice of surgical procedures on the digestive tract. Copyright © 2018 American Association of Gynecologic Laparoscopists. Published by Elsevier Inc. All rights reserved.

  2. Role of 3.0 Tesla magnetic resonance hysterosalpingography in the diagnostic work-up of female infertility.

    Science.gov (United States)

    Cipolla, Valentina; Guerrieri, Daniele; Pietrangeli, Daniela; Santucci, Domiziana; Argirò, Renato; de Felice, Carlo

    2016-09-01

    Imaging evaluation plays a crucial role in the diagnostic work-up of female infertility. In recent years, the possibility to evaluate tubal patency using 1.5 Tesla magnetic resonance (1.5T MR) has been studied. To assess the feasibility of 3.0 Tesla magnetic resonance (3.0T MR) hysterosalpingography and its role in the diagnostic work-up of female infertility and to evaluate if this fast "one-stop-shop" imaging approach should be proposed as a first-line examination. A total of 116 infertile women were enrolled in this prospective study; all underwent 3.0T MR hysterosalpingography. After standard imaging of the pelvis, tubal patency was assessed by acquiring 3D dynamic time-resolved T1-weighted (T1W) sequences during manual injection of 4-5 mL of contrast solution consisting of gadolinium and normal sterile saline. Images were evaluated by two radiologists with different experience in MR imaging (MRI). The examination was successfully completed in 96.5% of cases, failure rate was 3.5%. Dynamic sequences showed bilateral tubal patency in 64.3%, unilateral tubal patency in 25.9%, and bilateral tubal occlusion in 9.8%. Extratubal abnormalities were found in 69.9% of patients. Comprehensive analysis of morphological and dynamic sequences showed extratubal abnormalities in 43.1% of patients with bilateral tubal patency. 3.0T MR hysterosalpingography is a feasible, simple, fast, safe, and well-tolerated examination, which allows evaluation of tubal patency and other pelvic causes of female infertility in a single session, and it may thus represent a "one-stop-shop" solution in female infertility diagnostic work-up. © The Foundation Acta Radiologica 2015.

  3. Can hysterosalpingocontrast-sonography replace hysterosalpingography in the assessment of tubal subfertility?

    Energy Technology Data Exchange (ETDEWEB)

    Dijkman, Antonius B.; Mol, Ben W.J.; Veen, Fulco van der; Bossuyt, P.M.M.; Hogerzeil, Hendricus V

    2000-07-01

    Introduction: Hysterosalpingo-contrastsonography (HyCoSy) is a new method for assessing tubal patency using transvaginal ultrasound. It is thought to have several advantages over conventional hysterosalpingography (HSG). We prospectively evaluated the performance of HyCoSy and HSG in the diagnosis of tubal pathology. Methods and patients: One-hundred consecutive subfertile women underwent both HyCoSy and HSG in randomised order. Results of both tests were related to findings at laparoscopy with dye, which was used as the reference test. Each woman was asked to score the pain exsperienced at both procedures on a visual analogue scale. Results: When laparoscopy with dye was used as reference test, the likelihood ratios of HyCoSy were slightly inferior to those obtained for HSG. Since the performance of HyCoSy was dependent on experience, the results were recalculated omitting the 50 initial procedures from the analysis. In that calculation, results of HyCoSy and HSG were comparable. There were no differences in pain experienced during the procedure, as there appeared also to be no differences in patient preferences. Conclusion: There appear to be no strong arguments either to replace HSG by HyCoSy, or to reject the use of HyCoSy. Both procedures can be used in the evaluation of tubal pathology.

  4. Information seeking and perceptions of anxiety and pain among women undergoing hysterosalpingography.

    Science.gov (United States)

    Handelzalts, Jonathan E; Levy, Sigal; Peled, Yoav; Binyamin, Liat; Wiznitzer, Arnon; Goldzweig, Gil; Krissi, Haim

    2016-07-01

    Hysterosalpingography (HSG) is an accepted diagnostic tool for infertility workup and is considered an invasive procedure that is generally regarded as uncomfortable and painful, though research on psychological consequences is scarce and outdated. The study objective was to investigate women's experience of HSG in terms of fear, anxiety and pain, as compared to colposcopy. This cross sectional questionnaire study was conducted at two public women's health clinics in Israel between January 2013 and March 2014. 137 women were included in the study. 42 consecutively sampled women referred for outpatient HSG and 95 consecutively sampled women referred for outpatient diagnostic colposcopy. The main outcome measures were: state-trait anxiety, information seeking behavior, fear of pain, fear of the results, retrospective pain. Compared to those undergoing colposcopy, women undergoing HSG expressed significantly higher anxiety prior to the procedure, feared the pain involved more, and rated the procedure as more painful retrospectively. HSG patients tended to report a higher degree of information seeking. Information seeking was correlated with higher anxiety among HSG but not colposcopy patients. HSG is a highly stressful procedure associated with fear, anxiety, pain and information seeking. Research is needed to find possible ways of ameliorating these emotions and behaviors as they may have negative impact on patient cooperation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. [Comparison of diagnostic quality in hysterosalpingography between iodinated non-ionic contrast media with low and high osmolarity].

    Science.gov (United States)

    Piccotti, K; Guida, D; Carbonetti, F; Stefanetti, L; Macioce, A; Cremona, A; David, V

    Comparison of diagnostic quality in hysterosalpingography between low and high-osmolality contrast media. We performed a retrospective evaluation of two cohorts of patients who underwent HSG using contrast media with different osmolarity: the first group ,47 patients, underwent hysterosalpingography in the period September 2011-December 2012 using Iopromide 370 mg/ml; the second group, 50 patients, underwent HSG from January 2013 to October 2013 using Iomeprol 400 mg/ml. Three radiologists, in consensus reading,, reviewed the radiographs by assessing the following four parameters: opacification of the uterine cavity, uterine profiles definition, Fallopian tubes visualization, contrast media spillage into peritoneum. A score-scale from 0 to 3 was assigned for each of the mentioned parameter (0 = minimum non-diagnostic exam, 1 = sufficient examination; 2 = good quality examination; maximum 3 = high quality images). We documented a statistically significant higher quality in displaying Fallopian tubes among patients studied through high osmolarity contrast medium (Iopromide 370 mg/ml) than what obtained through lower osmolarity contrast medium (Iomeprol 400 mg/ml). The use of high osmolarity contrast medium enabled better visualization of the tubes and a greater number of diagnoses of chronic aspecific salpigintis due to the increased osmolality and viscosity of Iomeprol 400 mg/ml. There were no significant differences between the two contrast agents in the evaluation of intra-uterine pathology and in the evaluation of the tubal patency.

  6. Virtually teaching virtual leadership

    DEFF Research Database (Denmark)

    Henriksen, Thomas Duus; Nielsen, Rikke Kristine; Børgesen, Kenneth

    2017-01-01

    This paper seeks to investigate the challenges to virtual collaboration and leadership on basis of findings from a virtual course on collaboration and leadership. The course used for this experiment was designed as a practical approach, which allowed participants to experience curriculum phenomena....... This experimental course provided insights into the challenges involved in virtual processes, and those experiences where used for addressing the challenges that virtual leadership is confronted with. Emphasis was placed on the reduction of undesired virtual distance and its consequences through affinity building....... We found that student scepticism appeared when a breakdown resulted in increasing virtual distance, and raises questions on how leaders might translate or upgrade their understandings of leadership to handling such increased distance through affinity building....

  7. Comparison of hysterosalpingography and laparoscopy in the evaluation of infertile women

    International Nuclear Information System (INIS)

    Sakar, Mehmet N.; Atay, Ahmet E.; Gul, T.; Celik, Y.

    2008-01-01

    Objective was to compare tuboperitoneal factors of infertile women hysterosalpingography (HSG) and laparoscopy. In this cohort study, 82 infertile cases were evaluated retrospectively by laparoscopy, 3 months subsequent to HSG in the Department of Gynecology and Obstetrics, Medical School of Dicle University, Diyarbakir, Turkey between March 2004 and April 2006. The findings of HSG and laparoscopy were compared. Out of 82 infertile women, pathological findings were observed in 45.1% by HSG and 54.9% had no pathological findings. On laparoscopic evaluation, however, pathological findings were observed in 65.85% and 34.15% had no pathological findings. The pathological findings were detected by laparoscopy in 20 of the 45(44.4%) patients who had had no pathological findings by HSG and no pathological findings were detected by laparoscopy in 3 of the 37 (8.1%) patients who had pathological findings by HSG. Laparoscopy revealed no pathological findings in 6 of 35 patients who had tubal pathology by HSG. The sensitivity of HSG was 63%, specificity was 89.3% and positive predictive value was 92% with a 55% predictive value and the accuracy ratio was 72%. Laparoscopy is a superior method for the result of tubal and pelvic pathologies in the evaluation of infertility. However, HSG is a more economical and elementary method suitable for evaluation of endometrial and tubal pathologies and laparoscopy is an appropriate method for examining the external part of tubae, fimbriae, the relation of tuba and ovary, endometriosis, adhesions, tuberculosis and other pathologies. Therefore, these 2 methods are not alternative but complementary. (author)

  8. Hysterosalpingography After Radiofrequency Endometrial Ablation and Hysteroscopic Sterilization as a Concomitant Procedure.

    Science.gov (United States)

    Hopkins, Matthew R; Laughlin-Tommaso, Shannon K; Wall, Darci J; Breitkopf, Daniel M; Creedon, Douglas J; El-Nashar, Sherif A; Famuyide, Abimbola O

    2015-09-01

    To evaluate the accuracy of hysterosalpingography (HSG) in patients who underwent concomitant radiofrequency endometrial ablation and hysteroscopic sterilization. This historical cohort study was conducted at a midwestern academic medical center. A total of 186 women (94 with combined procedure and 92 with sterilization alone) were identified as having undergone intervention between January 1, 2003, and June 30, 2011. Two reviewers blinded to the surgical procedure interpreted the standard clinically indicated HSGs in each group. The primary outcome assessed was the inability to rely on the microinserts for contraception based on HSG interpretation using manufacturers' guidelines (unsatisfactory HSG). Position of the devices and occlusion of tubes were assessed on all 3-month and, when available, all 6-month repeat HSGs. At the 3-month HSG, 5 of 76 (6.6%, 95% confidence interval [CI] 2.2-14.7%) in the sterilization-only group had unsatisfactory HSG compared with 13 of 71 (18.3%, 95% CI 10.1-29.3%) in the combined group (P=.03). After accounting for the seven patients who underwent repeat HSG at 6 months, 3 of 76 (3.95%, 95% CI 0.8-11.1%) in the sterilization-only group had unsatisfactory HSG compared with 13 of 71 (18.31%, 95% CI 10.1-29.3%) in the combined group (P=.005). After completing all clinically indicated HSGs, patients who undergo concomitant radiofrequency endometrial ablation and hysteroscopic sterilization have an approximate fivefold increase (odds ratio 5.45, 95% CI 1.48-20.0) in the rate of unsatisfactory HSG for purposes of documenting tubal occlusion. II.

  9. Organizaciones Virtuales Organizaciones Virtuales

    Directory of Open Access Journals (Sweden)

    Gladis Cecilia Villegas Arias

    2003-06-01

    Full Text Available Virtual Organizations are new organizational forms originated from both the replacementof face to face communications by remote communications supported by electronic means,and from the accesibility of real time information about the operation of the company, forall employees.This article pursues the following goals: 1 To define virtual organization, review its sociotechnical antecedents and propose a preliminary classification into inter-organizationaland intra-organizational forms.  2 To discuss the characteristics of virtual organizationsand their impact on organizational design, and 3 To compare virtual organizations toother organizational forms.Las organizaciones virtuales son formas organizativas nuevas, que resultan de: primero, reemplazar las interacciones cara a cara con interacciones remotas, soportadas por comunicaciones electrónicas y segundo,  proveer acceso en tiempo real a toda la información de la empresa para todos los trabajadores.En este artículo se busca: 1 Definir organización virtual, revisar sus antecedentes y proponeruna clasificación básica preliminar de las mismas  2 Discutir las características de las organizaciones virtuales y sus implicaciones para el diseño organizativo 3 Comparar estaforma organizativa a las formas organizativas no virtuales.

  10. Advanced virtual monochromatic reconstruction of dual-energy unenhanced brain computed tomography in children: comparison of image quality against standard mono-energetic images and conventional polychromatic computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Juil [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Choi, Young Hun [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Cheon, Jung-Eun; Kim, Woo Sun; Kim, In-One [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Pak, Seong Yong [Siemens Healthineers, Seoul (Korea, Republic of); Krauss, Bernhard [Siemens Healthineers, Forchheim (Germany)

    2017-11-15

    Advanced virtual monochromatic reconstruction from dual-energy brain CT has not been evaluated in children. To determine the most effective advanced virtual monochromatic imaging energy level for maximizing pediatric brain parenchymal image quality in dual-energy unenhanced brain CT and to compare this technique with conventional monochromatic reconstruction and polychromatic scanning. Using both conventional (Mono) and advanced monochromatic reconstruction (Mono+) techniques, we retrospectively reconstructed 13 virtual monochromatic imaging energy levels from 40 keV to 100 keV in 5-keV increments from dual-source, dual-energy unenhanced brain CT scans obtained in 23 children. We analyzed gray and white matter noise ratios, signal-to-noise ratios and contrast-to-noise ratio, and posterior fossa artifact. We chose the optimal mono-energetic levels and compared them with conventional CT. For Mono+maximum optima were observed at 60 keV, and minimum posterior fossa artifact at 70 keV. For Mono, optima were at 65-70 keV, with minimum posterior fossa artifact at 75 keV. Mono+ was superior to Mono and to polychromatic CT for image-quality measures. Subjective analysis rated Mono+superior to other image sets. Optimal virtual monochromatic imaging using Mono+ algorithm demonstrated better image quality for gray-white matter differentiation and reduction of the artifact in the posterior fossa. (orig.)

  11. Advanced virtual monochromatic reconstruction of dual-energy unenhanced brain computed tomography in children: comparison of image quality against standard mono-energetic images and conventional polychromatic computed tomography.

    Science.gov (United States)

    Park, Juil; Choi, Young Hun; Cheon, Jung-Eun; Kim, Woo Sun; Kim, In-One; Pak, Seong Yong; Krauss, Bernhard

    2017-11-01

    Advanced virtual monochromatic reconstruction from dual-energy brain CT has not been evaluated in children. To determine the most effective advanced virtual monochromatic imaging energy level for maximizing pediatric brain parenchymal image quality in dual-energy unenhanced brain CT and to compare this technique with conventional monochromatic reconstruction and polychromatic scanning. Using both conventional (Mono) and advanced monochromatic reconstruction (Mono+) techniques, we retrospectively reconstructed 13 virtual monochromatic imaging energy levels from 40 keV to 100 keV in 5-keV increments from dual-source, dual-energy unenhanced brain CT scans obtained in 23 children. We analyzed gray and white matter noise ratios, signal-to-noise ratios and contrast-to-noise ratio, and posterior fossa artifact. We chose the optimal mono-energetic levels and compared them with conventional CT. For Mono+maximum optima were observed at 60 keV, and minimum posterior fossa artifact at 70 keV. For Mono, optima were at 65-70 keV, with minimum posterior fossa artifact at 75 keV. Mono+ was superior to Mono and to polychromatic CT for image-quality measures. Subjective analysis rated Mono+superior to other image sets. Optimal virtual monochromatic imaging using Mono+ algorithm demonstrated better image quality for gray-white matter differentiation and reduction of the artifact in the posterior fossa.

  12. Paracetamol as a prophylactic analgesic for hysterosalpingography: A double blind randomized controlled trial

    Energy Technology Data Exchange (ETDEWEB)

    Elson, E.M.; Ridley, N.T.F

    2000-09-01

    AIM: To evaluate the effectiveness of paracetamol as a prophylactic analgesic for hysterosalpingography (HSG). DESIGN: A prospective double blind randomized controlled trial comparing one 1 g of paracetamol (SmithKline Beecham, Brentford, U.K.) to placebo taken 30 min before HSG. One hundred consecutive out-patients were studied prospectively. The analgesic effectiveness during the procedure and at 24 h and 1 week post procedure was analysed by a postal pain score questionnaire. Additional data on the ethnicity of the patient, sex and level of experience of the radiologist performing the hysterosalpingogram, the parity of the patient, the ease of the procedure, and whether pathology was identified were also recorded. RESULTS: Eighty-eight patients (88%) replied, 39 (44%) received paracetamol and 49 placebo (56%). During the procedure 3/39 (7%) of women in the paracetamol group were pain-free compared to 9/49 (18%) in the placebo group, which was not significant (P = 0.11). At 24 h, 15/39 (38%) of women in the paracetamol group were pain-free compared to 20/49 (41%) in the placebo group, which was not significant (P = 0.82). At 1 week, 27/39 (69%) of women in the paracetamol group were pain-free compared to 29/49 (59%) in the placebo group, which was not significant (P = 0.33). No significant difference in mean pain scores was determined during the procedure (P 0.91), or at 24 h post procedure (P = 0.94). Similarly, no difference in mean pain scores was identified with regard to the ethnicity of the patient, the sex of the radiologist performing the procedure, the level of experience of the radiologist performing the procedure, or whether pathology was present or not. Difficult cannulations were associated with higher mean pain scores, however, there was no difference in mean pain scores between the paracetamol or placebo groups for both easy and difficult cannulations. CONCLUSION: Paracetamol is not effective as a prophylactic analgesic for HSG. If a prophylactic

  13. Feasibility of dynamic MR-hysterosalpingography for the diagnostic work-up of infertile women

    Energy Technology Data Exchange (ETDEWEB)

    Winter, Leopold; Gluecker, Thomas; Steinbrich, Wolfgang; Pegios, Wassilios (Dept. of Radiology, Univ. Hospital Basel (Switzerland)), e-mail: winterl@uhbs.ch; Steimann, Sabine; De Geyter, Christian (Women' s Hospital, Univ. Hospital Basel (Switzerland)); Froehlich, Johannes M. (Guerbet AG, Zuerich (Switzerland))

    2010-07-15

    Background: Tubal disturbances often contribute to infertility. Conventional hysterosalpingography (HSG) is considered as standard in the assessment of the patency of the fallopian tubes, but requires ionizing radiation and is restricted to the imaging of endoluminal structures. Purpose: To evaluate dynamic magnetic resonance-HSG (dMR-HSG) in the diagnostic work-up in patients with infertility. Material and Methods: Thirty-seven consecutive infertile women underwent dMR-HSG: 20 ml of gadolinium-polyvidone solution (18.4 mM Dotarem 1:20 with polyvidone) were injected intracervically through a 5-Charriere balloon catheter while acquiring five consecutive flash-3D T1-weighted MR sequences with fat saturation. Two experienced readers assessed image quality and anatomic-pathologic correlations prospectively. The relevance of results was evaluated in the clinical context of each patient. Patient comfort was evaluated with a standardized questionnaire. Results: dMR-HSG was successfully completed in 33/37 patient with an average study time of 45 min. In 4 of 37 patients the catheter became dislodged during the examination, resulting in two complete diagnostic failures. Failure in another two patients was due to preliminary termination because of excessive pain and discomfort during the application of the contrast solution. The uterine cavity was completely visualized and bilateral fallopian tube patency was confirmed by dMR-HSG in 27 of 33 patients. Bilateral tubal occlusion was diagnosed in one of the remaining six patients and was confirmed by laparoscopy. Successful selective tubal catheterization was performed in one additional patient with unilateral and one patient with bilateral fallopian tube occlusion. In three cases, the catheter became dislocated at the end of the examination without demonstration of tubal patency. Since all three patients refused diagnostic laparoscopy and conventional HSG, possible bilateral occlusions of the fallopian tubes could not be

  14. Clinical application of hysterosalpingography with a double-lumen catheter of a contrast media combination consisting iohexol and saline

    International Nuclear Information System (INIS)

    Xi Jiayuan; Jiang Yong; Cao Xinhua; Zhu Ying; Lv Liang; Zhao Xinxiang; Wei Dingying; Shao Jingxuan; Hua Jian

    2005-01-01

    Objective: To evaluate the clinical value of hysteosalpingographic diagnosis in infertile women. Methods: After a catheter with a double-lumen saccule was inserted into the uterine cavity, saline or air of 2.5-3.5 ml was injected to fill the saccule. The filled saccule was inserted at the isthmus of uterus for blocking the internal orifice. The contrast medium was injected through the catheter into the uterine cavity and fallopian tubes to undertake hysterosalpingography and fallopian tube reopening. In case of fallopian tube obstruction, the injection pressure could be increased to obtain recanalization. All operations and selective imagings were carried out under TV supervision. Results: 2698 cases including 806 primary infertile women and 1868 secondary infertile women were examined by this method. Technical success rate was 99.5% with 2198 cases (81.9%) having normal uterus, 249 (9.3%) congenital abnormal uterus and 238 (8.9%) uterus diseases. The number of obstructed fallopian tube was 3028 with 117 serious hydropsy (3.8%). Ninety-eight cases had been examined with lipiodol hysterosalpingography in other hospitals with 35 cases still having lipiodol accumulated within the uterine cavities and fallopian tubes. No serious complications or death occurred except slight pain. Conclusions: Double-lumen cather with a contrast media combination of iohexol and saline for hysterosal pinography is safe, easy and effective, outcoming with excellent quality images. More information can be gained with this method than traditional lipiodol hyterosalpinography, and furthermore could have compression during radiogrophy and avoid the long term stasis of lipiodol. (authors)

  15. The virtual knife

    DEFF Research Database (Denmark)

    Hansen, Mads Fogtmann

    and order books. The Danish Meat Research Institute (DMRI) is currently constructing a representative database of virtual representations of pigs using X-ray Computed Tomography (CT). The database will serve as the foundation for the diversity modeling of pigs and for extracting predictors of quality...... and optimal use. This thesis integrates well-known techniques from the medical image analysis into the development of tools for automated analysis of the morphology of pigs. E.g. elastic image matching has been applied to establish spatial correspondence between the virtual representations of pigs...

  16. On-line course as tools for radiation protection training in patients. A practical case in computerized tomography; El Aula Virtual como herramienta para la formacion en PR del paciente; caso practico en tomografia computarizada

    Energy Technology Data Exchange (ETDEWEB)

    Medina Campos, J.; Fernandez Tallon, J.; Busca Suau, J.; Baro Casanovas, J.

    2006-07-01

    The rise in ionizing radiation applications within the field of diagnostics, with the corresponding increase in both number and doses received by patients, requires adequate resources for education and training in radiological protection. In is quite difficult to assemble professionals at a specific place to carry out training. However, the use of Information and Communication Technologies (IT) makes it possible to carry out training. However, the use of Information and Communication Technologies (IT) makes it possible to carry out training through Internet in an effective, easy and amusing way (e-learning). An on-line course of patient radiological protection and quality control in computer tomography has been developed aimed at professionals that use these diagnostic techniques. The course has been run twice in the period 2005-2006. The course is found on an Internet-accessible Virtual Campus, which allows access to multimedia contents, communication between students and instructors and follow-up of students performance. Final evaluation is done on-line and successfully passing the course counts for 8.9 credits in the Continuous Education Programme of Spanish Health Systems. (Author)

  17. Virtual quad zygoma implant placement using cone beam computed tomography: sufficiency of malar bone volume, intraosseous implant length, and relationship to the sinus according to the degree of alveolar bone atrophy.

    Science.gov (United States)

    Bertos Quílez, J; Guijarro-Martínez, R; Aboul-Hosn Centenero, S; Hernández-Alfaro, F

    2018-02-01

    The objective of this study was to investigate the malar bone volume and length that a zygomatic implant can engage, and the relationship to the sinus according to the degree of alveolar bone atrophy. A three-dimensional evaluation was performed using cone beam computed tomography scans from 23 patients with a totally edentulous maxilla; quad zygoma implants were virtually placed. The predictor variable was the amount of malar bone volume and length that a zygomatic implant can engage. The primary outcome variable was the relationship to the sinus according to the degree of alveolar bone atrophy. Other variables were the residual alveolar bone height to the floor of the sinus and the nasal cavity. The mean volume of malar bone engaged in this sample of 92 zygomatic implants was 0.19±0.06cm 3 . The implant had an extrasinus path in 60.9% of cases, a parasinus path in 25%, and an intrasinus path in 14.1%. The results suggest that the average volume of malar bone engaged by a zygomatic implant is constant regardless of implant position and the degree of alveolar bone atrophy. As alveolar atrophy increases, the trajectory of the implant becomes more parasinus and intrasinus. The examiners were able to find enough bone to adequately distribute the implants in all cases. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography.

    Science.gov (United States)

    D'Angelo, Tommaso; Bucher, Andreas M; Lenga, Lukas; Arendt, Christophe T; Peterke, Julia L; Caruso, Damiano; Mazziotti, Silvio; Blandino, Alfredo; Ascenti, Giorgio; Othman, Ahmed E; Martin, Simon S; Leithner, Doris; Vogl, Thomas J; Wichmann, Julian L

    2018-04-01

    To define optimal window settings for displaying virtual monoenergetic images (VMI) of dual-energy CT pulmonary angiography (DE-CTPA). Forty-five patients who underwent clinically-indicated third-generation dual-source DE-CTPA were retrospectively evaluated. Standard linearly-blended (M_0.6), 70-keV traditional VMI (M70), and 40-keV noise-optimised VMI (M40+) reconstructions were analysed. For M70 and M40+ datasets, the subjectively best window setting (width and level, B-W/L) was independently determined by two observers and subsequently related with pulmonary artery attenuation to calculate separate optimised values (O-W/L) using linear regression. Subjective evaluation of image quality (IQ) between W/L settings were assessed by two additional readers. Repeated measures of variance were performed to compare W/L settings and IQ indices between M_0.6, M70, and M40+. B-W/L and O-W/L for M70 were 460/140 and 450/140, and were 1100/380 and 1070/380 for M40+, respectively, differing from standard DE-CTPA W/L settings (450/100). Highest subjective scores were observed for M40+ regarding vascular contrast, embolism demarcation, and overall IQ (all pwindow settings for VMI results in inferior image perception. • No significant differences between B-W/L and O-W/L for M70/M40+ were observed. • O-W/L for M70 were 450/140 and were 1070/380 for M40+. • Improved subjective IQ characteristics were observed for VMI displayed with O-W/L.

  19. Virtual Box

    DEFF Research Database (Denmark)

    Davis, Hilary; Skov, Mikael B.; Stougaard, Malthe

    2007-01-01

    . This paper reports on the design, implementation and initial evaluation of Virtual Box. Virtual Box attempts to create a physical and engaging context in order to support reciprocal interactions with expressive content. An implemented version of Virtual Box is evaluated in a location-aware environment...

  20. Effectiveness of a Single Education and Counseling Intervention in Reducing Anxiety in Women Undergoing Hysterosalpingography: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Alfredo La Fianza

    2014-01-01

    Full Text Available Hysterosalpingography (HSG is generally considered a stressful and painful procedure; we aimed to evaluate whether a single education and counseling intervention could reduce women’s distress and pain after undergoing HSG for infertility. Patients were randomized into control group (n=108 and intervention group (n=109. All patients filled the following questionnaires before and after HSG: Zung self-rating anxiety scale (Z-SAS, Zung self-rating depression scale (Z-SDS, and an ad hoc questionnaire designed to evaluate HSG procedure knowledge. Pain was scored using a visual analog scale. The intervention consisted in a 45-minute individualised session 48 h before HSG. We observed a reduction of anxiety and depression scores in the intervention arm compared to the control group. After controlling for potential confounding variables, intervention was an independent predictor of the difference of Z-SAS score before and after HSG. This is the first randomised controlled trial to assess the potential effectiveness of a single education and counseling intervention to lower anxiety in a diagnostic setting.

  1. Effectiveness of a single education and counseling intervention in reducing anxiety in women undergoing hysterosalpingography: a randomized controlled trial.

    Science.gov (United States)

    La Fianza, Alfredo; Dellafiore, Caterina; Travaini, Daniele; Broglia, Davide; Gambini, Francesca; Scudeller, Luigia; Tinelli, Carmine; Caverzasi, Edgardo; Brondino, Natascia

    2014-01-01

    Hysterosalpingography (HSG) is generally considered a stressful and painful procedure; we aimed to evaluate whether a single education and counseling intervention could reduce women's distress and pain after undergoing HSG for infertility. Patients were randomized into control group (n = 108) and intervention group (n = 109). All patients filled the following questionnaires before and after HSG: Zung self-rating anxiety scale (Z-SAS), Zung self-rating depression scale (Z-SDS), and an ad hoc questionnaire designed to evaluate HSG procedure knowledge. Pain was scored using a visual analog scale. The intervention consisted in a 45-minute individualised session 48 h before HSG. We observed a reduction of anxiety and depression scores in the intervention arm compared to the control group. After controlling for potential confounding variables, intervention was an independent predictor of the difference of Z-SAS score before and after HSG. This is the first randomised controlled trial to assess the potential effectiveness of a single education and counseling intervention to lower anxiety in a diagnostic setting.

  2. Fast-release orodispersible tramadol as analgesia in hysterosalpingography with a metal cannula or a balloon catheter.

    Science.gov (United States)

    Stoop, D; De Brucker, M; Haentjens, P; Talebian, A; de Mey, J; Devroey, P

    2010-06-01

    This study aimed to evaluate the potential benefit, in terms of pain relief, of the new oral fast-release orodispersible galvanic form of tramadol in women undergoing hysterosalpingography (HSG) with either a metal cannula or a balloon catheter. In a randomized, double-blind, placebo-controlled, 2 x 2 factorial-design trial, conducted at a single academic centre, 128 women were assigned into groups: (I) tramadol and a metal cannula, (II) tramadol and a balloon catheter, (III) placebo and a metal cannula or (IV) placebo and a balloon catheter. The primary end-point was pain registered by the patients on 10-cm visual analogue scales (VASs) at various times during and after the procedure. Secondary end-points included side effects and pain as assessed by the same physician during HSG. The main effect of tramadol versus placebo medication (i.e. I and II versus III and IV) was a statistically significant difference (P effect of the balloon catheter versus metal cannula (i.e. II and IV versus I and III) was a non-significant (P = 0.82) difference in patient-reported VAS of -0.05 (-0.49 to +0.39) and -2% (-21% to +17%). There were no medication-HSG device interactions and no differences in side effects. During and after HSG, fast-release orodispersible tramadol significantly reduces pain without increasing side effects.

  3. MR imaging of Asherman's syndrome in patients with and without uterine anomalies : comparison with hysterosalpingography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Sik; Kim, Hong; Kim, Taek Hoon [Keimyung Univ., DongSan Medical Center , Seoul (Korea, Republic of)

    1999-03-01

    To assess the role of MR imaging in the detection of Asherman's syndrome, especially when this is associated with a congenital uterine anomaly. MR images were obtained in the semicoronal plane parallel to the long axis of the uterus in 11 patients. Dilatation and curettage involving the insertion of an intrauterine device was performed in all patients, and transabdominal metroplasty was performed in four with uterine anomaly. MR imaging findings were compared with those of hysterosalpingography in all patients and compared with surgical findings in four. The MR findings of uterine synechia demonstrated in nine of 11 patients were focal thickening of the uterine junctional zone (n=2), hypointense foci in the endometrium (n=1), or both these findings (n=6). Seven of the 11 patients had associated uterine anomalies, which were demonstrated in all seven by MR imaging. In four of the seven, HSG failed to demonstrate these anomalies. MR imaging satisfactorily demonstrated intrauterine lesions in nine of 11 patients with Asherman's syndrome, and was especially helpful in demonstrating associated uterine anomalies.

  4. Wireless virtualization

    CERN Document Server

    Wen, Heming; Le-Ngoc, Tho

    2013-01-01

    This SpringerBriefs is an overview of the emerging field of wireless access and mobile network virtualization. It provides a clear and relevant picture of the current virtualization trends in wireless technologies by summarizing and comparing different architectures, techniques and technologies applicable to a future virtualized wireless network infrastructure. The readers are exposed to a short walkthrough of the future Internet initiative and network virtualization technologies in order to understand the potential role of wireless virtualization in the broader context of next-generation ubiq

  5. Virtual marketing in virtual enterprises

    OpenAIRE

    Ale Ebrahim, Nader; Fattahi, Hamaid Ali; Golnam, Arash

    2008-01-01

    Virtualization caused tremendous evolution in the economics of marketing channels, patterns of physical distribution and the structure of distributors and developed a new concept that is known as virtual marketing (VM). VM combines the powerful technologies of interactive marketing and virtual reality. Virtual enterprise (VE) refers to an organization not having a clear physical locus. In other words, VE is an organization distributed geographically and whose work is coordinated through e...

  6. Estimate of worker and patient exposures and quality control in hysterosalpingography exams; Estimativa da exposicao de pacientes e trabalhadores e controle de qualidade em exames de histerossalpingografia

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Barbara Beatriz Dias

    2006-06-15

    Hysterosalpingography (HSG) is a relatively frequent radiological procedure, which is used to access and study the uterine cavity and the tubary permeability. The estimate of the radiation doses received by the patients, and of the associated risks, has become of great interest in recent years. The importance in evaluating the received doses becomes even higher when the gonads region is irradiated; as in the case of hysterosalpingography, where the patients are relatively young, existing a high probability of future pregnancy. In HSG procedure the physician stays beside the patient, being also exposed. The purpose of this study was to analyze, during HSG procedures, the exposition of patients, measuring the kerma-area (P{sub K,A}) product by using an ionization chamber of big area, to evaluate the doses received by the radiologist using thermoluminescent dosemeters and to evaluate the quality of image by means of qualitative methods. The results gotten during the accompaniment of 86 examinations had been the following ones: the average P{sub K,A} was 706 {+-} 388 cGy.cm{sup 2}, to an average exposition time of 2 {+-} 1 minutes. In order to optimize the exposure of patients and workers, the time of scopy and the number of images should be reduced, whenever it is possible. Due to the significant values of equivalent dose received by the lens, the use of plumbiferous eyeglasses is recommended. (author)

  7. Virtual volatility

    Science.gov (United States)

    Silva, A. Christian; Prange, Richard E.

    2007-03-01

    We introduce the concept of virtual volatility. This simple but new measure shows how to quantify the uncertainty in the forecast of the drift component of a random walk. The virtual volatility also is a useful tool in understanding the stochastic process for a given portfolio. In particular, and as an example, we were able to identify mean reversion effect in our portfolio. Finally, we briefly discuss the potential practical effect of the virtual volatility on an investor asset allocation strategy.

  8. Virtual bronchoscopy

    International Nuclear Information System (INIS)

    Rogalla, P.; Meiri, N.; Hamm, B.; Rueckert, J.C.; Schmidt, B.; Witt, C.

    2001-01-01

    Flexible bronchoscopy represents a clinically well-established invasive diagnostic tool. Virtual bronchoscopies, calculated from thin-slice CT sections, allow astonishing immitations of reality although principal differences exist between both technologies: the Fact that colour representation is artificial and concommitant interventions are impossible limits the clinical use of virtual bronchoscopy. However, its value increases when calculations can be attained within minutes due to technological advancements, and when virtually any chest CT is suitable for further postprocessing. Indications, findings and the clinical role of virtual bronchoscopy are discussed. (orig.) [de

  9. Virtual projects

    DEFF Research Database (Denmark)

    Svejvig, Per; Commisso, Trine Hald

    2012-01-01

    that the best practice knowledge has not permeated sufficiently to the practice. Furthermore, the appropriate application of information and communication technology (ICT) remains a big challenge, and finally project managers are not sufficiently trained in organizing and conducting virtual projects....... The overall implications for research and practice are to acknowledge virtual project management as very different to traditional project management and to address this difference.......Virtual projects are common with global competition, market development, and not least the financial crisis forcing organizations to reduce their costs drastically. Organizations therefore have to place high importance on ways to carry out virtual projects and consider appropriate practices...

  10. Computerized Tomography

    International Nuclear Information System (INIS)

    Mirell, S.G.

    1979-01-01

    The physical bases of computerized tomography are presented, the following items being discussed:attenuation of a photon beam by an absorbent material, reconstruction algorithms and detection systems. Image statistics is also presented. The emission computerized tomography is discussed. Clinical results of computerized tomography are presented. (M.A.) [pt

  11. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography; Avaliacao de dose em procedimentos especiais de fluoroscopia: histerossalpingografia e dacriocistografia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Cintya Carolina Barbosa

    2006-04-15

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  12. Virtual Labs and Virtual Worlds

    Science.gov (United States)

    Boehler, Ted

    2006-12-01

    Virtual Labs and Virtual Worlds Coastline Community College has under development several virtual lab simulations and activities that range from biology, to language labs, to virtual discussion environments. Imagine a virtual world that students enter online, by logging onto their computer from home or anywhere they have web access. Upon entering this world they select a personalized identity represented by a digitized character (avatar) that can freely move about, interact with the environment, and communicate with other characters. In these virtual worlds, buildings, gathering places, conference rooms, labs, science rooms, and a variety of other “real world” elements are evident. When characters move about and encounter other people (players) they may freely communicate. They can examine things, manipulate objects, read signs, watch video clips, hear sounds, and jump to other locations. Goals of critical thinking, social interaction, peer collaboration, group support, and enhanced learning can be achieved in surprising new ways with this innovative approach to peer-to-peer communication in a virtual discussion world. In this presentation, short demos will be given of several online learning environments including a virtual biology lab, a marine science module, a Spanish lab, and a virtual discussion world. Coastline College has been a leader in the development of distance learning and media-based education for nearly 30 years and currently offers courses through PDA, Internet, DVD, CD-ROM, TV, and Videoconferencing technologies. Its distance learning program serves over 20,000 students every year. sponsor Jerry Meisner

  13. Virtual Exploratories

    DEFF Research Database (Denmark)

    Jensen, Sisse Siggaard

    2006-01-01

    -systems, the paper introduces the designing strategy referred to as virtual exploratories. Some of the advanced virtual worlds may inspire the design of such provoking and challenging virtual exploratories, and especially the Massively Multi-User Online Role-Playing Games (MMORPGS). However, if we have to learn from...... the design and activity of the advanced virtual worlds and role-playing games, then the empirical research on the actors’ activity, while they are acting, is an important precondition to it. A step towards the conception of such a designing strategy for virtual exploratories is currently pursued......, the sense-making ontology and triangle (Dervin et al., 2003), the video-interaction analysis (Henderson & Jordan, 1994), and the method of videoviews (Jensen, 2001, 2005). Also the two analytical concepts ‘intermediaries’ and ‘mediators’ that come from the actor-network theory (Latour, 2005) are introduced...

  14. Virtual Savannah

    DEFF Research Database (Denmark)

    Eskildsen, Søren; Rodil, Kasper; Rehm, Matthias

    2012-01-01

    It is a daunting task to visualize square kilometers of African savannah and currently in zoos it is impossible to present true African ecology to visitors. Virtual Savannah is a dynamic virtual world that introduces school children to a 3D representation of the wildlife sanctuaries Serengeti...... and the navigation. The test depicted how they managed to search the virtual world for answers in patterns related to restrictions in the system and using graphical points of interest as reference points. Collecting information about the complete interaction provides teachers with a tool to assess the individual...

  15. Computed Tomography

    Science.gov (United States)

    Castellano, Isabel; Geleijns, Jacob

    After its clinical introduction in 1973, computed tomography developed from an x-ray modality for axial imaging in neuroradiology into a versatile three dimensional imaging modality for a wide range of applications in for example oncology, vascular radiology, cardiology, traumatology and even in interventional radiology. Computed tomography is applied for diagnosis, follow-up studies and screening of healthy subpopulations with specific risk factors. This chapter provides a general introduction in computed tomography, covering a short history of computed tomography, technology, image quality, dosimetry, room shielding, quality control and quality criteria.

  16. Virtual care

    DEFF Research Database (Denmark)

    Kamp, Annette; Aaløkke Ballegaard, Stinne

    of retrenchment, promising better quality, empowerment of citizens and work that is smarter and more qualified. Through ethnographic field studies we study the introduction of virtual home care in Danish elderly care, focusing on the implications for relational work and care relations. Virtual home care entails...... and professionals, and they instigate change in organization and professional identities. Studies, which more specifically deal with telecare, stress how virtualization alters the character of the observations care workers are able to make, and how the validity of the patients’ own measurements and observations...... point out how issues of trust and surveillance, which are always negotiated in care relations, are in fact accentuated in this kind of virtual care work. Moreover, we stress that the contemporary institutional context, organization and time schedules have a vast impact on the practices developed....

  17. Virtual Savannah

    DEFF Research Database (Denmark)

    Eskildsen, Søren; Rodil, Kasper; Rehm, Matthias

    2012-01-01

    It is a daunting task to visualize square kilometers of African savannah and currently in zoos it is impossible to present true African ecology to visitors. Virtual Savannah is a dynamic virtual world that introduces school children to a 3D representation of the wildlife sanctuaries Serengeti...... and Masai Mara. The objective is to substitute supplementary textual information currently used in schools and provide the teacher with information about each pupil. The Virtual Savannah was tested in situ on 19 pupils age 10-11 with the purpose of logging all interaction with animals, GUI...... and the navigation. The test depicted how they managed to search the virtual world for answers in patterns related to restrictions in the system and using graphical points of interest as reference points. Collecting information about the complete interaction provides teachers with a tool to assess the individual...

  18. Virtual data

    International Nuclear Information System (INIS)

    Bjorklund, E.

    1993-01-01

    In the 1970's, when computers were memory limited, operating system designers created the concept of ''virtual memory'' which gave users the ability to address more memory than physically existed. In the 1990s, many large control systems have the potential for becoming data limited. We propose that many of the principles behind virtual memory systems (working sets, locality, caching, and clustering) can also be applied to data-limited systems - creating, in effect, ''virtual data systems.'' At the Los Alamos National Laboratory's Clinton P. Anderson Meson Physics Facility (LAMPF), we have applied these principles to a moderately sized (10,000 data points) data acquisition and control system. To test the principles, we measured the system's performance during tune-up, production, and maintenance periods. In this paper, we present a general discussion of the principles of a virtual data system along with some discussion of our own implementation and the results of our performance measurements

  19. Virtual Workshop

    DEFF Research Database (Denmark)

    Buus, Lillian; Bygholm, Ann

    In relation to the Tutor course in the Mediterranean Virtual University (MVU) project, a virtual workshop “Getting experiences with different synchronous communication media, collaboration, and group work” was held with all partner institutions in January 2006. More than 25 key-tutors within MVU...... participated from different institutions in the workshop. The result of the workshop was experiences with different communication tools and media. Facing the difficulties and possibilities in collaborateting virtually concerned around group work and development of a shared presentation. All based on getting...... experiences for the learning design of MVU courses. The workshop intented to give the participants the possibility to draw their own experiences with issues on computer supported collaboration, group work in a virtual environment, synchronous and asynchronous communication media, and different perspectives...

  20. Virtual Worlds for Virtual Organizing

    Science.gov (United States)

    Rhoten, Diana; Lutters, Wayne

    The members and resources of a virtual organization are dispersed across time and space, yet they function as a coherent entity through the use of technologies, networks, and alliances. As virtual organizations proliferate and become increasingly important in society, many may exploit the technical architecture s of virtual worlds, which are the confluence of computer-mediated communication, telepresence, and virtual reality originally created for gaming. A brief socio-technical history describes their early origins and the waves of progress followed by stasis that brought us to the current period of renewed enthusiasm. Examination of contemporary examples demonstrates how three genres of virtual worlds have enabled new arenas for virtual organizing: developer-defined closed worlds, user-modifiable quasi-open worlds, and user-generated open worlds. Among expected future trends are an increase in collaboration born virtually rather than imported from existing organizations, a tension between high-fidelity recreations of the physical world and hyper-stylized imaginations of fantasy worlds, and the growth of specialized worlds optimized for particular sectors, companies, or cultures.

  1. Monte Carlo based estimation of organ and effective doses to patients undergoing hysterosalpingography and retrograde urethrography fluoroscopy procedures

    Science.gov (United States)

    Ngaile, J. E.; Msaki, P. K.; Kazema, R. R.

    2018-04-01

    Contrast investigations of hysterosalpingography (HSG) and retrograde urethrography (RUG) fluoroscopy procedures remain the dominant diagnostic tools for the investigation of infertility in females and urethral strictures in males, respectively, owing to the scarcity and high cost of services of alternative diagnostic technologies. In light of the radiological risks associated with contrast based investigations of the genitourinary tract systems, there is a need to assess the magnitude of radiation burden imparted to patients undergoing HSG and RUG fluoroscopy procedures in Tanzania. The air kerma area product (KAP), fluoroscopy time, number of images, organ dose and effective dose to patients undergoing HSG and RUG procedures were obtained from four hospitals. The KAP was measured using a flat transmission ionization chamber, while the organ and effective doses were estimated using the knowledge of the patient characteristics, patient related exposure parameters, geometry of examination, KAP and Monte Carlo calculations (PCXMC). The median values of KAP for the HSG and RUG were 2.2 Gy cm2 and 3.3 Gy cm2, respectively. The median organ doses in the present study for the ovaries, urinary bladder and uterus for the HSG procedures, were 1.0 mGy, 4.0 mGy and 1.6 mGy, respectively, while for urinary bladder and testes of the RUG were 3.4 mGy and 5.9 mGy, respectively. The median values of effective doses for the HSG and RUG procedures were 0.65 mSv and 0.59 mSv, respectively. The median values of effective dose per hospital for the HSG and RUG procedures had a range of 1.6-2.8 mSv and 1.9-5.6 mSv, respectively, while the overall differences between individual effective doses across the four hospitals varied by factors of up to 22.0 and 46.7, respectively for the HSG and RUG procedures. The proposed diagnostic reference levels (DRLs) for the HSG and RUG were for KAP 2.8 Gy cm2 and 3.9 Gy cm2, for fluoroscopy time 0.8 min and 0.9 min, and for number of images 5 and 4

  2. Virtual Tower

    International Nuclear Information System (INIS)

    Wayne, R.A.

    1997-01-01

    The primary responsibility of an intrusion detection system (IDS) operator is to monitor the system, assess alarms, and summon and coordinate the response team when a threat is acknowledged. The tools currently provided to the operator are somewhat limited: monitors must be switched, keystrokes must be entered to call up intrusion sensor data, and communication with the response force must be maintained. The Virtual tower is an operator interface assembled from low-cost commercial-off-the-shelf hardware and software; it enables large amounts of data to be displayed in a virtual manner that provides instant recognition for the operator and increases assessment accuracy in alarm annunciator and control systems. This is accomplished by correlating and fusing the data into a 360-degree visual representation that employs color, auxiliary attributes, video, and directional audio to prompt the operator. The Virtual Tower would be a valuable low-cost enhancement to existing systems

  3. Virtual Sustainability

    Directory of Open Access Journals (Sweden)

    William Sims Bainbridge

    2010-09-01

    Full Text Available In four ways, massively multiplayer online role-playing games may serve as tools for advancing sustainability goals, and as laboratories for developing alternatives to current social arrangements that have implications for the natural environment. First, by moving conspicuous consumption and other usually costly status competitions into virtual environments, these virtual worlds might reduce the need for physical resources. Second, they provide training that could prepare individuals to be teleworkers, and develop or demonstrate methods for using information technology to replace much transportation technology, notably in commuting. Third, virtual worlds and online games build international cooperation, even blending national cultures, thereby inching us toward not only the world consciousness needed for international agreements about the environment, but also toward non-spatial government that cuts across archaic nationalisms. Finally, realizing the potential social benefits of this new technology may urge us to reconsider a number of traditional societal institutions.

  4. Virtual toolbox

    Science.gov (United States)

    Jacobus, Charles J.; Jacobus, Heidi N.; Mitchell, Brian T.; Riggs, A. J.; Taylor, Mark J.

    1993-04-01

    At least three of the five senses must be fully addressed in a successful virtual reality (VR) system. Sight, sound, and touch are the most critical elements for the creation of the illusion of presence. Since humans depend so much on sight to collect information about their environment, this area has been the focus of much of the prior art in virtual reality, however, it is also crucial that we provide facilities for force, torque, and touch reflection, and sound replay and 3-D localization. In this paper we present a sampling of hardware and software in the virtual environment maker's `toolbox' which can support rapidly building up of customized VR systems. We provide demonstrative examples of how some of the tools work and we speculate about VR applications and future technology needs.

  5. EDITORIAL: Process Tomography

    Science.gov (United States)

    Wang, Mi

    2006-08-01

    Process tomography (PT) refers to a methodology by which the internal characteristics of process vessel reaction or pipeline flows are acquired from measurements on or outside the domain of interest in a non-invasive fashion. As a generic 'tool' PT is extremely useful in improving, for example, the modelling and design of many complex processes, in understanding the dynamic mechanisms of flowing and mixing of colloidal dispersions, and in multiphase flow phenomena, hydraulic transport and process control. Over two decades of research worldwide, PT has become a routine research tool in many research laboratories and is being accepted for process measurement and control in some industrial applications. This is the fourth special feature on process tomography after previous publications in this journal in 1996, 2001 and 2002. In this issue, recent developments in sensors, measurements and algorithms with new features for specific distinctive applications are addressed, such as the high temporal resolutions of 1000 frames/s and beyond obtained by both x-ray and impedance tomography for flow measurement and fast process reaction; interferometric tomography combining the Mach Zehnder interferometer and tomography to utilize the phase difference in propagation for visualization of particular features in a process and new three-dimensional image reconstruction algorithms in process applications. The important aspect of this issue is that it demonstrates current developments focusing on the improvement of performance at the temporal resolution, phase information and 3D algorithms for specific application. Looking back over two decades of research, we can see that the process tomography technique is maturing and its applications in industrial manufacture are being deployed as a result of the determined efforts of researchers worldwide. As Guest Editor of this special feature, I would like to thank my colleagues at the Virtual Centre for Industrial Process Tomography (VCIPT

  6. Virtualize Me!

    Science.gov (United States)

    Waters, John K.

    2009-01-01

    John Abdelmalak, director of technology for the School District of the Chathams, was pretty sure it was time to jump on the virtualization bandwagon last year when he invited Dell to conduct a readiness assessment of his district's servers. When he saw just how little of their capacity was being used, he lost all doubt. Abdelmalak is one of many…

  7. Virtual patrolling.

    NARCIS (Netherlands)

    van der Vlist, M.; Wismans, Luc Johannes Josephus; van Beek, P.; Suijs, L.C.W.

    2016-01-01

    Approximately 25 per cent of all congestion on motorways is caused by incidents. By virtual patrolling, incidents e.g. queues, accidents and car breakdowns on a road network, can be predicted or detected in an early stage. This early detection and prediction of an incident likely to happen, offers

  8. Virtual patrolling

    NARCIS (Netherlands)

    van der Vlist, M.; Wismans, Luc Johannes Josephus; van Beek, P.; Suijs, L.C.W.

    2016-01-01

    Approximately 25 per cent of all congestion on motorways is caused by incidents. By virtual patrolling, incidents e.g. queues, accidents and car breakdowns on a road network, can be predicted or detected in an early stage. This early detection and prediction of an incident likely to happen, offers

  9. Virtual modeling

    NARCIS (Netherlands)

    Flores, J.; Kiss, S.; Cano, P.; Nijholt, Antinus; Zwiers, Jakob

    2003-01-01

    We concentrate our efforts on building virtual modelling environments where the content creator uses controls (widgets) as an interactive adjustment modality for the properties of the edited objects. Besides the advantage of being an on-line modelling approach (visualised just like any other on-line

  10. Virtual reality and anthropology

    International Nuclear Information System (INIS)

    Recheis, Wolfgang; Weber, Gerhard W.; Schaefer, Katrin; Knapp, Rudolf; Seidler, Horst; Zur Nedden, Dieter

    1999-01-01

    Since the discovery of the Tyrolean Iceman in 1991 advanced imaging and post processing techniques were successfully applied in anthropology. Specific techniques include spiral computed tomography and 3-dimensional reconstructions including stereolithographic and fused deposition modeling of volume data sets. The Iceman's skull was the first to be reproduced using stereolithography, before this method was successfully applied in preoperative planning. With the advent of high-end graphics workstations and biomedical image processing software packages, 3-dimensional reconstructions were established as a routine tool for analyzing volume data sets. These techniques opened totally new insights in the field of physical anthropology. Computed tomography became the ideal research tool to access the internal structures of various precious fossils without damaging or even touching them. Many of the most precious specimens from the species Autralopithecus (1.8-3.5 Myears), Homo heidelbergensis (200-600 kyears) or Homo neanderthalensis (40-100 kyears) were scanned during the last 5 years. Often the fossils are filled with a stone matrix or other materials. During the postprocessing routines highly advanced algorithms were used to remove virtually these incrustations. Thus it was possible to visualize the morphological structures that lie beneath the matrix. Some specimens were partially destroyed, so the missing parts were reconstructed on computer screen in order to get estimations of the brain volume and endocranial morphology, both major fields of interest in physical anthropology. Moreover the computerized form of the data allows new descriptions of morphologic structures by the means of 'geometric morphometrics'. Some of the results may change aspects and interpretations in human evolution. The introduction of new imaging and post processing techniques created a new field of research: Virtual Anthropology

  11. Protective effects of vitamin C and vitamin E against hysterosalpingography-induced epithelial degeneration and proliferation in rat endometrium

    Directory of Open Access Journals (Sweden)

    Pala Ş

    2016-12-01

    Full Text Available Şehmus Pala,1 Remzi Atilgan,1 Tuncay Kuloğlu,2 Murat Kara,3 Melike Başpinar,1 Behzat Can,1 Gökhan Artaş4 1Department of Obstetrics and Gynecology, 2Department of Histology and Embriology, Firat University School of Medicine, Elazig, 3Department of Medical Biology and Genetics, Muğla Sıtkı Koçman University School of Medicine, Muğla, 4Department of Pathology, Firat University School of Medicine, Elazig, Turkey Aim: The aim of this study was to examine the protective effects of vitamin C (VC and vitamin E (VE against hysterosalpingography (HSG-induced epithelial degeneration and proliferation in rat endometrium. Materials and methods: A total of 28 female Wistar albino rats were randomized into four groups: G1 (n=7; abdomen was opened and closed, G2 (n=7; 0.1 mL Lipiodol [ethiodized oil] was administered to each uterine horn in conjunction with X-ray irradiation, G3 (n=7; 50 mg/kg of intraperitoneal (ip VC was administered, followed by the administration of 0.1 mL of ethiodized oil into the uterine horns after 15 minutes, and G4 (n=7; 50 mg/kg of ip VE was administered, followed by the administration of 0.1 mL of ethiodized oil into the uterine horns after 15 minutes. After abdominal closure, rats in G2, G3 and G4 groups were exposed to whole-body X-irradiation three times with 2-minute intervals at a total dose of 15–20 mrad. Three hours after exposure, abdominal cavities of all the rats were reopened and uterine horns were removed. The right uterine horns were embedded into paraffin blocks after fixing in 10% formaldehyde for histopathological and immunohistochemical examination. Uterine horns on the other side were rapidly excised and stored at -80°C for the examination of expression of microRNAs (miRNAs and oxidant, antioxidant, apoptotic and antiapoptotic gene expression using real-time polymerase chain reaction (RT-PCR method. Results: No differences were observed in terms of expression of miRNAs and oxidant

  12. Sensorial Virtualization: Coupling Gaming and Virtual Environment

    NARCIS (Netherlands)

    Garbaya, S.; Miraoui, C.; Wendrich, Robert E.; Lim, T.; Stanescu, I.A.; Hauge, J.B.

    2014-01-01

    Virtual reality and virtualization are currently used to design complex systems and demonstrate that they represent the functionalities of real systems. However, the design refinement of the virtual environment (VE) and distributed virtual environment (DVE) are still time consuming and costly, as it

  13. Virtual anthropology.

    Science.gov (United States)

    Weber, Gerhard W

    2015-02-01

    Comparative morphology, dealing with the diversity of form and shape, and functional morphology, the study of the relationship between the structure and the function of an organism's parts, are both important subdisciplines in biological research. Virtual anthropology (VA) contributes to comparative morphology by taking advantage of technological innovations, and it also offers new opportunities for functional analyses. It exploits digital technologies and pools experts from different domains such as anthropology, primatology, medicine, paleontology, mathematics, statistics, computer science, and engineering. VA as a technical term was coined in the late 1990s from the perspective of anthropologists with the intent of being mostly applied to biological questions concerning recent and fossil hominoids. More generally, however, there are advanced methods to study shape and size or to manipulate data digitally suitable for application to all kinds of primates, mammals, other vertebrates, and invertebrates or to issues regarding plants, tools, or other objects. In this sense, we could also call the field "virtual morphology." The approach yields permanently available virtual copies of specimens and data that comprehensively quantify geometry, including previously neglected anatomical regions. It applies advanced statistical methods, supports the reconstruction of specimens based on reproducible manipulations, and promotes the acquisition of larger samples by data sharing via electronic archives. Finally, it can help identify new, hidden traits, which is particularly important in paleoanthropology, where the scarcity of material demands extracting information from fragmentary remains. This contribution presents a current view of the six main work steps of VA: digitize, expose, compare, reconstruct, materialize, and share. The VA machinery has also been successfully used in biomechanical studies which simulate the stress and strains appearing in structures. Although

  14. Virtual crimes

    OpenAIRE

    Pobořilová, Michaela

    2010-01-01

    Virtual crimes are a new specific area in the law system, which is associated with information technologies (mobile, Internet etc.). These are crimes that can be committed in cyberspace or in connection with it. Generally, cyberspace can be defined from different perspectives most often as social, technological and legal environment in which there is mutual interaction of its users. This environment, in particular the Internet, due to its characteristics such as unlimited local, speed, low co...

  15. Virtual Cystoscopy

    International Nuclear Information System (INIS)

    Mejia Restrepo, Jorge; Aldana S, Natalia; Munoz Sierra, Juan; Lopez Amaya, Juan

    2011-01-01

    Introduction: virtual cystoscopy is a minimally invasive procedure that facilitates the evaluation of the urinary tract, allowing intraluminal navigation through the urinary tract structures on the basis of CT imaging reconstructions. it allows detection of various pathologies of the system, through high-sensitivity, three-dimensional lesion visualization with some advantages over conventional cystoscopy. Objective: to describe the technique used for virtual cystoscopy at our institution,and present some representative cases. Materials and methods: We describe the main indications, advantages and limitations of the method, followed by a description of the technique used in our institution, and finally, we present five representative cases of bladder and urethral pathology. Conclusion: virtual cystoscopy is a sensitive technique for the diagnosis of bladder tumors, even those smaller than 5mm. it is the preferred method in patients who have contraindications for conventional cystoscopy, such as prostate hyperplasia, urethral stenoses and active haematuria.it is less invasive and has a lower complication rate when compared with conventional cystoscopy. It has limited use in the assessment of the mucosa and of small, flat lesions.

  16. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  17. Periodismo virtual

    Directory of Open Access Journals (Sweden)

    Carlos Morales

    2015-01-01

    Full Text Available El periodismo virtual se produce en diarios que no ofrecen noticias (concebidas como versión o reflejo de la realidad sino que crean sus propias ficciones, especialmente en primeras planas. El autor del artículo señala que esto esta sucediendo en LA NACIÓN de San José de Costa Rica, diario premiado por la inefable Sociedad Interamericana de Prensa - SIP - y periódico económicamente más importante del país.

  18. Assessment in dogs tympanic bulla, through virtual tomographic endoscopy; Avaliacao de bulas timpanicas em caes, por meio da endoscopia tomografica virtual

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Luciana Carandina da; Sabino, Emanuelle Guidugli, E-mail: lucianacarandina@uol.com.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria. Dept. de Reproducao Animal e Radiologia Veterinaria; Vulcano, Luiz Carlos; Machado, Vania Maria de Vasconcelos [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria

    2012-07-01

    Dogs usually have problems related to the auditory canal. For the diagnosis of these pathologies, it is necessary a physical examination and, in some cases radiographic examination and computed tomography. The tympanic bulla is not easily visualized radiographically, since there is many structures of the brain overlaying the image obtained. The computed tomography has been the technique of choice to assess this structure faithfully. A new alternative assessment of the tympanic bulla is tomographic virtual endoscopy, which allows an improvement of the image obtained through the virtual tomographic technique. This paper provides information on the use of computed tomography, and a new technique, tomographic virtual endoscopy, in order to make the improvement of these techniques, and prove the reliability of these changes in the diagnosis of ear canals of dogs. Therefore, we performed the computed tomography of the tympanic bulla on healthy animals, and later performed image reconstruction in three-dimensional (3D) mode for virtual endoscopy. (author)

  19. Realidad virtual y materialidad

    OpenAIRE

    Pérez Herranz, Fernando Miguel

    2009-01-01

    1. Fenomenología de partida: Real / Simbólico / Imaginario 2. Realidad 3. Virtual 3.1. Virtual / real / posible / probable 3.2. Los contextos de la realidad virtual A) REALIDAD VIRTUAL INMERSIVA B) REALIDAD VIRTUAL NO INMERSIVA C) REALIDAD VIRTUAL Y DIGITALIZACIÓN 3.3. Cruce virtual / real 3.4. Cuestiones filosóficas 4. Materialidad 5. Materialidad y descentramiento 5.1. Ejemplos de descentramiento en los contextos de Realidad Virtual A’) DUALISMO CARTESIANO, CUERPO Y «CIBORG » B’) EL ESPÍRIT...

  20. Virtual Touch

    DEFF Research Database (Denmark)

    Stenslie, Ståle

    The central focus of this thesis is the use and experience of touch in artistic, multimodal and computer-based environments. The haptic experience of touch is an area that has only received limited research-based interest. Touch is too often seen as the effect, and not the cause of our everyday...... experiences. The study aims to provide an improved knowledge of how touch functions and how haptic storytelling can be used as an artistic medium. This thesis is divided into seven parts. The introductory chapter presents the structure of the study and the history leading up the formulation of research...... Erotogod. The third chapter investigates the foundations of touch through a physiological and psychological approach. Chapter four presents an alternative haptic history of Virtual Realities through the presentation and discussion of several technological and artistic works that are computer...

  1. Realidad virtual

    OpenAIRE

    García García, Alberto Luis

    2000-01-01

    Las nuevas tecnologías, basadas en el mundo digital propuesto por la informática, están cambiando nuestra forma de entender el mundo, tanto desde el punto de vista sociocultural como económico. La realidad virtual se vale de códigos icónicos, y con ello se convierte en un paso más hacia la supresión de toda barrera linguística, para llegar a conseguir la gran comunidad global. Es necesario conocer en toda su extensión, una tecnología que está cambiando el modo de comunicarnos. Estos son, a gr...

  2. Atelier Virtual

    OpenAIRE

    Leite, Luzirene do Rego

    2007-01-01

    Esta dissertação trata da proposição de um atelier virtual que contribua para arte-educação a distância. A origem desta idéia foi definida no trabalho desenvolvido durante minha experiência no Grupo Arteduca, formado por professores que atuam no Instituto de Artes da Universidade de Brasília e, mais especificamente, no curso "Arteduca: Arte, Educação e Tecnologias Contemporâneas". O foco desta dissertação está direcionado para a produção artística em ambientes virtuais de aprendizagem, por me...

  3. From virtual environment to virtual community

    NARCIS (Netherlands)

    Nijholt, Antinus; Terano, Takao; Nishida, Toyoaki; Namatame, Akira; Tsumoto, Syusaku; Ohsawa, Yukido; Washio, Takashi

    2001-01-01

    We discuss a virtual reality theater environment and its transition to a virtual community by adding domain agents and by allowing multiple users to visit this environment. The environment has been built using VRML (Virtual Reality Modeling Language). We discuss how our ideas about this environment

  4. Emission tomography for adrenal imaging

    International Nuclear Information System (INIS)

    Britton, K.E.; Shapiro, B.; Hawkins, L.A.

    1980-01-01

    Single photon emission tomography (SPET) of the adrenals was compared to convential gamma camera images. Depths of 19 adrenals were assessed by both the lateral skin-upper kidney pole method and by SPET. Eleven patients with adrenal disorders were also studied. An advantage of using SPET was that the analogue transverse section image showed improvement over the conventional posterior view because the liver activity was well separated from the adrenal. Furthermore, non-adrenal tissue background was virtually eliminated and adrenal depth determination facilitated. (U.K.)

  5. Microsoft Virtualization Master Microsoft Server, Desktop, Application, and Presentation Virtualization

    CERN Document Server

    Olzak, Thomas; Boomer, Jason; Keefer, Robert M

    2010-01-01

    Microsoft Virtualization helps you understand and implement the latest virtualization strategies available with Microsoft products. This book focuses on: Server Virtualization, Desktop Virtualization, Application Virtualization, and Presentation Virtualization. Whether you are managing Hyper-V, implementing desktop virtualization, or even migrating virtual machines, this book is packed with coverage on all aspects of these processes. Written by a talented team of Microsoft MVPs, Microsoft Virtualization is the leading resource for a full installation, migration, or integration of virtual syste

  6. First Exclusive Measurement of Deeply Virtual Compton Scattering off He4 : Toward the 3D Tomography of Nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Hattawy, M.; Baltzell, N. A.; Dupré, R.; Hafidi, K.; Stepanyan, S.; Bültmann, S.; De Vita, R.; El Alaoui, A.; El Fassi, L.; Egiyan, H.; Girod, F. X.; Guidal, M.; Jenkins, D.; Liuti, S.; Perrin, Y.; Torayev, B.; Voutier, E.; Adhikari, K. P.; Adhikari, S.; Adikaram, D.; Akbar, Z.; Amaryan, M. J.; Anefalos Pereira, S.; Armstrong, Whitney R.; Avakian, H.; Ball, J.; Bashkanov, M.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Biselli, A. S.; Boiarinov, S.; Briscoe, W. J.; Brooks, W. K.; Burkert, V. D.; Thanh Cao, Frank; Carman, D. S.; Celentano, A.; Charles, G.; Chetry, T.; Ciullo, G.; Clark, L.; Colaneri, L.; Cole, P. L.; Contalbrigo, M.; Cortes, O.; Crede, V.; D’Angelo, A.; Dashyan, N.; De Sanctis, E.; Deur, A.; Djalali, C.; Elouadrhiri, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Fersch, R.; Filippi, A.; Fleming, J. A.; Forest, T. A.; Fradi, A.; Garçon, M.; Gevorgyan, N.; Ghandilyan, Y.; Gilfoyle, G. P.; Giovanetti, K. L.; Gleason, C.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guo, L.; Hakobyan, H.; Hanretty, C.; Harrison, N.; Heddle, D.; Hicks, K.; Holtrop, M.; Hughes, S. M.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jiang, H.; Joo, K.; Joosten, S.; Keller, D.; Khachatryan, G.; Khachatryan, M.; Khandaker, M.; Kim, A.; Kim, W.; Klein, A.; Klein, F. J.; Kubarovsky, V.; Kuhn, S. E.; Kuleshov, S. V.; Lanza, L.; Lenisa, P.; Livingston, K.; Lu, H. Y.; MacGregor, I. J. D.; Markov, N.; Mayer, M.; McCracken, M. E.; McKinnon, B.; Meyer, C. A.; Meziani, Z. E.; Mineeva, T.; Mirazita, M.; Mokeev, V.; Montgomery, R. A.; Moutarde, H.; Movsisyan, A.; Munoz Camacho, C.; Nadel-Turonski, P.; Net, L. A.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Paolone, M.; Paremuzyan, R.; Park, K.; Pasyuk, E.; Phelps, E.; Phelps, W.; Pisano, S.; Pogorelko, O.; Price, J. W.; Prok, Y.; Protopopescu, D.; Ripani, M.; Ritchie, B. G.; Rizzo, A.; Rosner, G.; Rossi, P.; Sabatié, F.; Salgado, C.; Schumacher, R. A.; Seder, E.; Sharabian, Y. G.; Simonyan, A.; Skorodumina, Iu.; Smith, G. D.; Sokhan, D.; Sparveris, N.; Strauch, S.; Taiuti, M.; Ungaro, M.; Voskanyan, H.; Walford, N. K.; Watts, D. P.; Wei, X.; Weinstein, L. B.; Wood, M. H.; Zachariou, N.; Zana, L.; Zhang, J.; Zhao, Z. W.

    2017-11-01

    We report on the first measurement of the beam-spin asymmetry in the exclusive process of coherent deeply virtual Compton scattering off a nucleus. The experiment uses the 6 GeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) accelerator at Jefferson Lab incident on a pressurized He-4 gaseous target placed in front of the CEBAF Large Acceptance Spectrometer (CLAS). The scattered electron is detected by CLAS and the photon by a dedicated electromagnetic calorimeter at forward angles. To ensure the exclusivity of the process, a specially designed radial time projection chamber is used to detect the recoiling He-4 nuclei. We measure beam-spin asymmetries larger than those observed on the free proton in the same kinematic domain. From these, we are able to extract, in a model-independent way, the real and imaginary parts of the only He-4 Compton form factor, HA. This first measurement of coherent deeply virtual Compton scattering on the He-4 nucleus, with a fully exclusive final state via nuclear recoil tagging, leads the way toward 3D imaging of the partonic structure of nuclei.

  7. Virtual colonoscopy: clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Laghi, A. [Univ. of Rome La Sapienza, Polo Didattico Pontino, Latina (Italy)

    2005-11-15

    Virtual colonoscopy (VC), also known as computed tomography Colonography (CTC), is a non-invasive test for the examination of the colon based on volumetric, thin-collimation CT acquisition of a cleansed and air-distended colon. The technique is easy, less labour-intensive than barium enema and conventional colonoscopy, and is inherently safer. Several studies demonstrate the ability of VC in the detection of colonic neoplastic lesions, not only large carcinomas, but also polyps. Currently, the most widely accepted clinical indication is incomplete or unsuccessful colonoscopy, which may be the result of redundant colon, patient intolerance to the procedure, spasm not resolving even with the use of spasmolytics, obstructing colo-rectal cancer. VC is also used to detect cancer in frail and immobile patients to avoid sedation during colonoscopy or the turning required during barium enema. The use of VC in patients under surveillance following colo-rectal cancer surgery is under investigation. Further studies are necessary in order to assess the cost-effectiveness of this approach. For colo-rectal cancer screening, a practical approach is to consider VC as a currently credible alternative screening method and as a reasonable alternative to the other colo-rectal cancer screening tests when a patient is unable or unwilling to undergo conventional colonoscopy. (orig.)

  8. Virtual colonoscopy: clinical application

    International Nuclear Information System (INIS)

    Laghi, A.

    2005-01-01

    Virtual colonoscopy (VC), also known as computed tomography Colonography (CTC), is a non-invasive test for the examination of the colon based on volumetric, thin-collimation CT acquisition of a cleansed and air-distended colon. The technique is easy, less labour-intensive than barium enema and conventional colonoscopy, and is inherently safer. Several studies demonstrate the ability of VC in the detection of colonic neoplastic lesions, not only large carcinomas, but also polyps. Currently, the most widely accepted clinical indication is incomplete or unsuccessful colonoscopy, which may be the result of redundant colon, patient intolerance to the procedure, spasm not resolving even with the use of spasmolytics, obstructing colo-rectal cancer. VC is also used to detect cancer in frail and immobile patients to avoid sedation during colonoscopy or the turning required during barium enema. The use of VC in patients under surveillance following colo-rectal cancer surgery is under investigation. Further studies are necessary in order to assess the cost-effectiveness of this approach. For colo-rectal cancer screening, a practical approach is to consider VC as a currently credible alternative screening method and as a reasonable alternative to the other colo-rectal cancer screening tests when a patient is unable or unwilling to undergo conventional colonoscopy. (orig.)

  9. Virtual cystoscopy.

    Science.gov (United States)

    Mohammed, Aza; Simpson, Adam; Zamora, Ignacio; Gilliland, Leslie

    2008-07-01

    Bladder cancer is a common problem facing urologists worldwide. The gold standard for its diagnosis and follow-up is the direct visualization of the tumor using conventional cystoscopy. Despite having high sensitivity and specificity for detecting bladder cancer, conventional cystoscopy is regarded as an invasive procedure which is associated with several complications. In addition, regular follow-up of patients with bladder cancer is a financial burden on the health system. With the progressive development in diagnostic imaging and medical computer software technologies, it was possible to generate virtual reality images to aid the clinician to inspect the interior of the bladder in real time. This technology is considered as a safe test for bladder cancer diagnosis and follow-up, and it is associated with cancer detection rates comparable with conventional cystoscopy. However, it is associated with some drawbacks that limit its use in routine clinical practice at the current time. In this paper, we review the development and clinical applications of this technology.

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special ... the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a CT ...

  11. Virtual reality in education

    OpenAIRE

    Minocha, Shailey; Tudor, Ana-Despina

    2017-01-01

    In this workshop-presentation, we described the evolution of virtual reality technologies and our research from 3D virtual worlds, 3D virtual environments built in gaming environments such as Unity 3D, 360-degree videos, and mobile virtual reality via Google Expeditions. For each of these four technologies, we discussed the affordances of the technologies and how they contribute towards learning and teaching. We outlined the significance of students being aware of the different virtual realit...

  12. Virtual reality - aesthetic consequences

    OpenAIRE

    Benda, Lubor

    2014-01-01

    In the present work we study aesthetic consequences of virtual reality. Exploring the fringe between fictional and virtual is one of the key goals, that will be achieved through etymologic and technologic definition of both fiction and virtual reality, fictional and virtual worlds. Both fiction and virtual reality will be then studied from aesthetic distance and aesthetic pleasure point of view. At the end, we will see the main difference as well as an common grounds between fiction and virtu...

  13. Positron Emission Tomography - Computed Tomography (PET/CT)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Positron Emission Tomography - Computed Tomography (PET/CT) Positron emission tomography (PET) ... Emission Tomography – Computed Tomography (PET/CT)? What is Positron Emission Tomography – Computed Tomography (PET/CT) Scanning? Positron emission tomography, ...

  14. Virtual Goods Recommendations in Virtual Worlds

    Directory of Open Access Journals (Sweden)

    Kuan-Yu Chen

    2015-01-01

    Full Text Available Virtual worlds (VWs are computer-simulated environments which allow users to create their own virtual character as an avatar. With the rapidly growing user volume in VWs, platform providers launch virtual goods in haste and stampede users to increase sales revenue. However, the rapidity of development incurs virtual unrelated items which will be difficult to remarket. It not only wastes virtual global companies’ intelligence resources, but also makes it difficult for users to find suitable virtual goods fit for their virtual home in daily virtual life. In the VWs, users decorate their houses, visit others’ homes, create families, host parties, and so forth. Users establish their social life circles through these activities. This research proposes a novel virtual goods recommendation method based on these social interactions. The contact strength and contact influence result from interactions with social neighbors and influence users’ buying intention. Our research highlights the importance of social interactions in virtual goods recommendation. The experiment’s data were retrieved from an online VW platform, and the results show that the proposed method, considering social interactions and social life circle, has better performance than existing recommendation methods.

  15. Virtual Trackballs Revisited

    DEFF Research Database (Denmark)

    Henriksen, Knud; Sporring, Jon; Hornbæk, Kasper

    2004-01-01

    Rotation of three-dimensional objects by a two-dimensional mouse is a typical task in computer-aided design, operation simulations, and desktop virtual reality. The most commonly used rotation technique is a virtual trackball surrounding the object and operated by the mouse pointer. This article...... reviews and provides a mathematical foundation for virtual trackballs. The first, but still popular, virtual trackball was described by Chen et al. [CHECK END OF SENTENCE]. We show that the virtual trackball by Chen et al. does not rotate the object along the intended great circular arc on the virtual...... trackball and we give a correction. Another popular virtual trackball is Shoemake's quaternion implementation [CHECK END OF SENTENCE], which we show to be a special case of the virtual trackball by Chen et al.. Shoemake extends the scope of the virtual trackball to the full screen. Unfortunately, Shoemake...

  16. Offline fusion of co-registered intravascular ultrasound and frequency domain optical coherence tomography images for the analysis of human atherosclerotic plaques

    DEFF Research Database (Denmark)

    Räber, Lorenz; Heo, Jung Ho; Radu, Maria D

    2012-01-01

    To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images.......To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images....

  17. Parsimonious Refraction Interferometry and Tomography

    KAUST Repository

    Hanafy, Sherif

    2017-02-04

    We present parsimonious refraction interferometry and tomography where a densely populated refraction data set can be obtained from two reciprocal and several infill shot gathers. The assumptions are that the refraction arrivals are head waves, and a pair of reciprocal shot gathers and several infill shot gathers are recorded over the line of interest. Refraction traveltimes from these shot gathers are picked and spawned into O(N2) virtual refraction traveltimes generated by N virtual sources, where N is the number of geophones in the 2D survey. The virtual traveltimes can be inverted to give the velocity tomogram. This enormous increase in the number of traveltime picks and associated rays, compared to the many fewer traveltimes from the reciprocal and infill shot gathers, allows for increased model resolution and a better condition number with the system of normal equations. A significant benefit is that the parsimonious survey and the associated traveltime picking is far less time consuming than that for a standard refraction survey with a dense distribution of sources.

  18. The Internet and medical collaboration using virtual reality.

    Science.gov (United States)

    Liang, Wen Yau; O'Grady, Peter

    2003-01-01

    Computed Tomography (CT) provides a large amount of data but the presentation of the data to a physician can be less than satisfactory. Ideally, the image data should be available to physicians in interactive 3D to allow for improved visualization, planning and diagnosis. A virtual reality representation that not only allows for the manipulation of the image but also allows for the user to, in effect, move inside the image remotely would be ideal. In this paper the research associated with virtual reality is discussed. A formalism is then presented to create, from the CT data, the virtual reality world in the Virtual Reality Modeling Language. An implementation is described of this formalism that uses the Internet to allow for users in remote locations to view and manipulate the virtual worlds.

  19. Virtual reality simulator for vitreoretinal surgery using integrated OCT data.

    Science.gov (United States)

    Kozak, Igor; Banerjee, Pat; Luo, Jia; Luciano, Cristian

    2014-01-01

    Operative practice using surgical simulators has become a part of training in many surgical specialties, including ophthalmology. We introduce a virtual reality retina surgery simulator capable of integrating optical coherence tomography (OCT) scans from real patients for practicing vitreoretinal surgery using different pathologic scenarios.

  20. Virtual Trackballs Revisited

    OpenAIRE

    Henriksen, Knud; Sporring, Jon; Hornbæk, Kasper

    2004-01-01

    Udgivelsesdato: March/April Rotation of three-dimensional objects by a two-dimensional mouse is a typical task in computer-aided design, operation simulations, and desktop virtual reality. The most commonly used rotation technique is a virtual trackball surrounding the object and operated by the mouse pointer. This article reviews and provides a mathematical foundation for virtual trackballs. The first, but still popular, virtual trackball was described by Chen et al. [CHECK END OF SENTENC...

  1. Server virtualization solutions

    OpenAIRE

    Lodziņš, Gunārs Ernests

    2007-01-01

    Currently in the information technology sector that is responsible for a server infrastructure is a huge development in the field of server virtualization on x86 computer architecture. As a prerequisite for such a virtualization development is growth in server productivity and underutilization of available computing power. Several companies in the market are working on two virtualization architectures – hypervizor and hosting. In this paper several of virtualization products that use host...

  2. Virtual reality exposure therapy

    OpenAIRE

    Rothbaum, BO; Hodges, L; Kooper, R

    1997-01-01

    It has been proposed that virtual reality (VR) exposure may be an alternative to standard in vivo exposure. Virtual reality integrates real-time computer graphics, body tracking devices, visual displays, and other sensory input devices to immerse a participant in a computer- generated virtual environment. Virtual reality exposure is potentially an efficient and cost-effective treatment of anxiety disorders. VR exposure therapy reduced the fear of heights in the first control...

  3. Designing Virtual Worlds

    DEFF Research Database (Denmark)

    Gürsimsek, Remzi Ates

    2014-01-01

    mediators in 3D virtual space to collaborate and co-design the digital content. These co-designers are also the residents of these worlds, as they socialize by building inworld friendships. This article presents a social semiotic analysis of the three-dimensional virtual places and artifacts in the virtual...... the audio-visual characteristics of designing in multi-user virtual environments generate experiential, interpersonal and textual meaning potentials....

  4. Comparison between virtual museums

    Directory of Open Access Journals (Sweden)

    Simona Caraceni

    2014-04-01

    Full Text Available Drawing a taxonomy of virtual museum, that can fit to represent all the known cases of virtual museum in the last years, I tried to try my meta-model of classification in two very different examples of virtual museums, to prove the validity of my taxonomical meta-model.

  5. High availability using virtualization

    Science.gov (United States)

    Calzolari, Federico

    2009-10-01

    High availability has always been one of the main problems for a data center. Till now high availability was achieved by host per host redundancy, a highly expensive method in terms of hardware and human costs. A new approach to the problem can be offered by virtualization. Using virtualization, it is possible to achieve a redundancy system for all the services running on a data center. This new approach to high availability allows to share the running virtual machines over the servers up and running, by exploiting the features of the virtualization layer: start, stop and move virtual machines between physical hosts. The system (3RC) is based on a finite state machine with hysteresis, providing the possibility to restart each virtual machine over any physical host, or reinstall it from scratch. A complete infrastructure has been developed to install operating system and middleware in a few minutes. To virtualize the main servers of a data center, a new procedure has been developed to migrate physical to virtual hosts. The whole Grid data center SNS-PISA is running at the moment in virtual environment under the high availability system. As extension of the 3RC architecture, several storage solutions have been tested to store and centralize all the virtual disks, from NAS to SAN, to grant data safety and access from everywhere. Exploiting virtualization and ability to automatically reinstall a host, we provide a sort of host on-demand, where the action on a virtual machine is performed only when a disaster occurs.

  6. A Virtual Class Calculus

    DEFF Research Database (Denmark)

    Ernst, Erik; Ostermann, Klaus; Cook, William Randall

    2006-01-01

    model for virtual classes has been a long-standing open question. This paper presents a virtual class calculus, vc, that captures the essence of virtual classes in these full-fledged programming languages. The key contributions of the paper are a formalization of the dynamic and static semantics of vc...

  7. METRIC OF VIRTUAL WORLDS

    OpenAIRE

    Trunev A. P.

    2013-01-01

    We investigate the hypothesis of a plurality of parallel and virtual worlds. It is assumed that sentient beings in each virtual world reach a stage of development that can create a virtual world to simulate the history of their own development. In this case, the virtual worlds are nested within each other, which put a severe restriction on the possible geometry of space-time. Discussed the draft geometry virtual worlds consistently displayed from one world to another. It is shown that in this...

  8. Virtualization A Manager's Guide

    CERN Document Server

    Kusnetzky, Dan

    2011-01-01

    What exactly is virtualization? As this concise book explains, virtualization is a smorgasbord of technologies that offer organizations many advantages, whether you're managing extremely large stores of rapidly changing data, scaling out an application, or harnessing huge amounts of computational power. With this guide, you get an overview of the five main types of virtualization technology, along with information on security, management, and modern use cases. Topics include: Access virtualization-Allows access to any application from any deviceApplication virtualization-Enables applications

  9. Coronary artery fly-through using electron beam computed tomography

    NARCIS (Netherlands)

    van Ooijen, P M; Oudkerk, M; van Geuns, R J; Rensing, B J; de Feyter, P J

    2000-01-01

    BACKGROUND: Virtual reality techniques have recently been introduced into clinical medicine. This study examines the possibility of coronary artery fly-through using a dataset obtained by noninvasive coronary angiography with contrast-enhanced electron-beam computed tomography. METHODS AND RESULTS:

  10. ViRPET--combination of virtual reality and PET brain imaging

    Science.gov (United States)

    Majewski, Stanislaw; Brefczynski-Lewis, Julie

    2017-05-23

    Various methods, systems and apparatus are provided for brain imaging during virtual reality stimulation. In one example, among others, a system for virtual ambulatory environment brain imaging includes a mobile brain imager configured to obtain positron emission tomography (PET) scans of a subject in motion, and a virtual reality (VR) system configured to provide one or more stimuli to the subject during the PET scans. In another example, a method for virtual ambulatory environment brain imaging includes providing stimulation to a subject through a virtual reality (VR) system; and obtaining a positron emission tomography (PET) scan of the subject while moving in response to the stimulation from the VR system. The mobile brain imager can be positioned on the subject with an array of imaging photodetector modules distributed about the head of the subject.

  11. Virtual Reality: Principles and Applications

    OpenAIRE

    MÉRIENNE , Frédéric

    2017-01-01

    Virtual reality aims at immersing a user in a virtual environment. Dedicated virtual reality technologies of human–computer interaction enable to make the link between the user and a virtual environment in capturing the user’s motion, acting on his senses as well as computing the virtual experience in real-time. The immersion in virtual environment is evaluated through the user’s perception and reaction. Virtual reality is used in a large variety of application domains which need multisensory...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography ( ... cross-sectional images generated during a CT scan can be reformatted in multiple planes, and can even ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT of the sinuses is primarily used ...

  14. Review of muon tomography

    International Nuclear Information System (INIS)

    Feng Hanliang; Jiao Xiaojing

    2010-01-01

    As a new detection technology, Muon tomography has some potential benefits, such as being able to form a three- dimensional image, without radiation, low cost, fast detecting etc. Especially, muon tomography will play an important role in detecting nuclear materials. It introduces the theory of Muon tomography, its advantages and the Muon tomography system developed by decision sciences corporation and Los Alamos national laboratory. (authors)

  15. Spectral and Diffraction Tomography

    OpenAIRE

    Lionheart, William

    2016-01-01

    We discuss several cases of what we call "Rich Tomography" problems in which more data is measured than a scalar for each ray. We give examples of infra red spectral tomography and Bragg edge neutron tomography in which the data is insufficient. For diffraction tomography of strain for polycrystaline materials we give an explicit reconstruction procedure. We go on to describe a way to find six independent rotation axes using Pascal's theorem of projective geometry

  16. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Perfusion of the Head CT Angiography (CTA) Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography ( ...

  18. Virtual reality for engineering

    CERN Document Server

    De Gennaro, Silvano; CERN. Geneva

    1996-01-01

    Virtual Reality for Engineers. Virtual Reality is a very powerful visualization technique for 3D data, which can bring enormous benefits to engineering design. CAD models can be exported to a VR application and used as "Virtual Prototypes". Virtual Prototypes are an ideal replacement for wooden models as they can be generated automatically from most CAD products. They are totally reliable, they can be updated in a matter of minutes, and they allow designers to explore them from inside, on a one-to-one scale and using a 3D-stereo vision. Navigation can be performed using a number of instinctive tools, such as joysticks, spaceballs, VR helmets and 3D mice. The lectures will cover today's Virtual Reality products and methods, and describe how to transform CAD models into Virtual Prototypes. A "hands on" VR experience featuring the LHC detectors models can be organized for people interested.

  19. Transforming Virtual Teams

    DEFF Research Database (Denmark)

    Bjørn, Pernille

    2005-01-01

    Investigating virtual team collaboration in industry using grounded theory this paper presents the in-dept analysis of empirical work conducted in a global organization of 100.000 employees where a global virtual team with participants from Sweden, United Kingdom, Canada, and North America were...... studied. The research question investigated is how collaboration is negotiated within virtual teams? This paper presents findings concerning how collaboration is negotiated within a virtual team and elaborate the difficulties due to invisible articulation work and managing multiple communities...... in transforming the virtual team into a community. It is argued that translucence in communication structures within the virtual team and between team and management is essential for engaging in a positive transformation process of trustworthiness supporting the team becoming a community, managing the immanent...

  20. Learning by doing virtually.

    Science.gov (United States)

    von Sternberg, N; Bartsch, M S; Petersik, A; Wiltfang, J; Sibbersen, W; Grindel, T; Tiede, U; Warnke, P H; Heiland, M; Russo, P A J; Terheyden, H; Pohlenz, P; Springer, I N

    2007-05-01

    Selective reduction of bone without collateral damage (nerves, teeth) is essential in apicectomy. To test whether skills acquired on a virtual apicectomy simulator (VOXEL-MAN system with integrated force-feedback) are transferable from virtual to physical reality, two groups of trainees were compared. Group 1 received computer-based virtual surgical training before performing an apicectomy in a pig cadaver model. The probability of preserving vital neighboring structures was improved significantly, i.e. six-fold, after virtual surgical training (P<0.001). The average volume of the bony defects created by the trainees of Group 2 (mean: 0.47 ml) was significantly (P<0.001) larger than by the trainees of Group 1 (mean: 0.25 ml). Most importantly, the ability to objectively self-assess performance was significantly improved after virtual training. Training with a virtual apicectomy simulator appears to be effective, and the skills acquired are transferable to physical reality.

  1. Post-mortem virtual estimation of free abdominal blood volume

    International Nuclear Information System (INIS)

    Ampanozi, Garyfalia; Hatch, Gary M.; Ruder, Thomas D.; Flach, Patricia M.; Germerott, Tanja; Thali, Michael J.; Ebert, Lars C.

    2012-01-01

    Purpose: The purpose of this retrospective study was to examine the reliability of virtually estimated abdominal blood volume using segmentation from postmortem computed tomography (PMCT) data. Materials and methods: Twenty-one cases with free abdominal blood were investigated by PMCT and autopsy. The volume of the blood was estimated using a manual segmentation technique (Amira, Visage Imaging, Germany) and the results were compared to autopsy data. Six of 21 cases had undergone additional post-mortem computed tomographic angiography (PMCTA). Results: The virtually estimated abdominal blood volumes did not differ significantly from those measured at autopsy. Additional PMCTA did not bias data significantly. Conclusion: Virtual estimation of abdominal blood volume is a reliable technique. The virtual blood volume estimation is a useful tool to deliver additional information in cases where autopsy is not performed or in cases where a postmortem angiography is performed

  2. Virtual Campus Hub technology

    DEFF Research Database (Denmark)

    Vercoulen, Frank; Badger, Merete; Monaco, Lucio

    This deliverable briefly describes which technological components have been delivered for the Virtual Campus Hub and how they can be used. A detailed discussion of the technical details of the components, how they were realized and how they fit the VCH concept can be found in deliverables D5.......4. Virtual Campus Hub Technology Evaluation Report and D6.7 The Virtual Campus Hub Concept....

  3. Trust and virtual worlds

    DEFF Research Database (Denmark)

    Ess, Charles; Thorseth, May

    2011-01-01

    by virtuality, such as virtual child pornography. The introduction further develops a philosophical anthropology, rooted in Kantian ethics, phenomenology, virtue ethics, and feminist perspectives, that grounds a specific approach to ethical issues in virtual environments....... of embodiment in establishing trust in (primarily) disembodied venues; how far artificial agents and other forms of machine intelligence can be trusted in any strong sense; and how diverse ethical frameworks, as developed in embodied contexts and histories, may (not) be applied to ethical issues evoked...

  4. Photon virtual bound state

    International Nuclear Information System (INIS)

    Inoue, J.; Ohtaka, K.

    2004-01-01

    We study virtual bound states in photonics, which are a vectorial extension of electron virtual bound states. The condition for these states is derived. It is found that the Mie resonant state which satisfies the condition that the size parameter is less than the angular momentum should be interpreted as a photon virtual bound state. In order to confirm the validity of the concept, we compare the photonic density of states, the width of which represents the lifetime of the photon virtual bound states, with numerical results

  5. High availability using virtualization

    International Nuclear Information System (INIS)

    Calzolari, Federico; Arezzini, Silvia; Ciampa, Alberto; Mazzoni, Enrico; Domenici, Andrea; Vaglini, Gigliola

    2010-01-01

    High availability has always been one of the main problems for a data center. Till now high availability was achieved by host per host redundancy, a highly expensive method in terms of hardware and human costs. A new approach to the problem can be offered by virtualization. Using virtualization, it is possible to achieve a redundancy system for all the services running on a data center. This new approach to high availability allows the running virtual machines to be distributed over a small number of servers, by exploiting the features of the virtualization layer: start, stop and move virtual machines between physical hosts. The 3RC system is based on a finite state machine, providing the possibility to restart each virtual machine over any physical host, or reinstall it from scratch. A complete infrastructure has been developed to install operating system and middleware in a few minutes. To virtualize the main servers of a data center, a new procedure has been developed to migrate physical to virtual hosts. The whole Grid data center SNS-PISA is running at the moment in virtual environment under the high availability system.

  6. Secure Virtual Enclaves

    National Research Council Canada - National Science Library

    Shands, Deborah

    2002-01-01

    The Secure Virtual Enclaves (SVE) collaboration infrastructure allows multiple organizations to share their distributed application resources, while respecting organizational autonomy over local resources...

  7. Virtual Training Devices Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Virtual Training Devices (VTD) Laboratory at the Life Cycle Software Engineering Center, Picatinny Arsenal, provides a software testing and support environment...

  8. Virtual Environments for Training

    National Research Council Canada - National Science Library

    Stiles, R

    1998-01-01

    .... Progress on productization of the VET Training Studio software includes increased robustness for Vista virtual environment display and interaction services, a new capability to use the STEVE visual...

  9. Virtual Reality Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Performs basic and applied research in interactive 3D computer graphics, including visual analytics, virtual environments, and augmented reality (AR). The...

  10. Super-virtual refraction interferometry: Theory

    KAUST Repository

    Bharadwaj, Pawan

    2011-01-01

    Inverting for the subsurface velocity distribution by refraction traveltime tomography is a well-accepted imaging method by both the exploration and earthquake seismology communities. A significant drawback, however, is that the recorded traces become noisier with increasing offset from the source position, and so prevents accurate picking of traveltimes in far-offset traces. To enhance the signal-to-noise ratio of the far-offset traces, we present the theory of super-virtual refraction interferometry where the signal-to-noise ratio (SNR) of far-offset head-wave arrivals can be theoretically increased by a factor proportional to N; here, N is the number of receiver and source positions associated with the recording and generation of the head-wave arrival. There are two steps to this methodology: correlation and summation of the data to generate traces with virtual head-wave arrivals, followed by the convolution of the data with the virtual traces to create traces with super-virtual head-wave arrivals. This method is valid for any medium that generates head-wave arrivals. There are at least three significant benefits to this methodology: 1). enhanced SNR of far-offset traces so the first-arrival traveltimes of the noisy far-offset traces can be more reliably picked to extend the useful aperture of data, 2). the SNR of head waves in a trace that arrive after the first arrival can be enhanced for accurate traveltime picking and subsequent inversion by traveltime tomography, and 3). common receiver-pair gathers can be analyzed to detect the presence of diving waves in the first arrivals, which can be used to assess the nature of the refracting boundary. © 2011 Society of Exploration Geophysicists.

  11. Super-Virtual Refraction Interferometric Redatuming: Enhancing the Refracted Energy

    KAUST Repository

    Aldawood, Ali

    2012-02-26

    onshore seismic data processing. Refraction tomography is becoming a common way to estimate an accurate near surface velocity model. One of the problems with refraction tomography is the low signal to noise ration in far offset data. To improve, we propose using super-virtual refraction interferometry to enhance the weak energy at far offsets. We use Interferometric Green\\'s functions to redatum sources by cross-correlating two traces recorded at receiver stations, A and B, from a source at location W. The result is a redatumed trace with a virtual source at A and a receiver at B, which can also be obtained by correlating two traces recorded at A and B from different shots. Stacking them would enhance the signal-to-noise ratio of this "virtual" trace. We next augment redatuming with convolution and stacking. The trace recorded at B from a virtual source at A is convolved with the original trace recorded at A from a source at W. The result is a "super-virtual" trace at B in the far-offset from a source at W. Stacking N traces gives a vN-improvement. We applied our method to noisy synthetic and field data recorded over a complex near-surface and we could pick more traces at far offsets. It was possible to accommodate more picks resulting in a better subsurface coverage

  12. The virtual GULLIVER project

    NARCIS (Netherlands)

    Trappl, R.; Nijholt, Antinus; Stuk, M.; Zwiers, Jakob

    2002-01-01

    In this paper we discuss our virtual reality project Gulliver. This project is part of a more comprehensive project conceived by two artists, Matjaž Štuk and Alena Hudcovicová, called “Gulliver’s Museum of Living Art��?. Our part of the project involves a virtual reality version of Swift’s Gulliver

  13. 10 Myths of Virtualization

    Science.gov (United States)

    Schaffhauser, Dian

    2012-01-01

    Half of servers in higher ed are virtualized. But that number's not high enough for Link Alander, interim vice chancellor and CIO at the Lone Star College System (Texas). He aspires to see 100 percent of the system's infrastructure requirements delivered as IT services from its own virtualized data centers or other cloud-based operators. Back in…

  14. A Virtual Good Idea

    Science.gov (United States)

    Bolch, Matt

    2009-01-01

    School districts across the country have always had to do more with less. Funding goes only so far, leaving administrators and IT staff to find innovative ways to save money while maintaining a high level of academic quality. Creating virtual servers accomplishes both tasks, district technology personnel say. Virtual environments not only allow…

  15. Virtual Seminar Room

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Fosgerau, Anders; Hansen, Peter Søren Kirk

    1999-01-01

    The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented.......The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented....

  16. OVERLAPPING VIRTUAL CADASTRAL DOCUMENTATION

    Directory of Open Access Journals (Sweden)

    Madalina - Cristina Marian

    2013-12-01

    Full Text Available Two cadastrale plans of buildings, can overlap virtual. Overlap is highlighted when digital reception. According to Law no. 7/1996 as amended and supplemented, to solve these problems is by updating the database graphs, the repositioning. This paper addresses the issue of overlapping virtual cadastre in the history of the period 1999-2012.

  17. Virtual Peace Education

    Science.gov (United States)

    Firer, Ruth

    2008-01-01

    This article is based on the convictions that peace education is the basis for any sustainable non-violent relations between parties in a conflict, and that virtual peace education is almost the only feasible way to practise peace education in an open violent conflict as is the current Israeli/Palestinians one. Moreover, virtual peace education…

  18. Designing Virtual Learning Environments

    DEFF Research Database (Denmark)

    Veirum, Niels Einar

    2003-01-01

    The main objective of this working paper is to present a conceptual model for media integrated communication in virtual learning environments. The model for media integrated communication is very simple and identifies the necessary building blocks for virtual place making in a synthesis of methods...

  19. Digging the Virtual Past

    Science.gov (United States)

    Polymeropoulou, Panagiota

    2014-01-01

    In this paper we will investigate the way that the technological progress and the Informatics contributed greatly to the field of Archaeology. There will be analyzed the terms of virtual archaeology and virtual reality in archaeology and there will be an extended reference to the applications and the computer graphics that archaeologists could use…

  20. Virtual Company and Modelbank

    DEFF Research Database (Denmark)

    Thorsteinsson, Uffe

    1996-01-01

    Ansøgning til Socrates programmet vedr. Tematisk netværk inden for området Virtual Company and Modelbank......Ansøgning til Socrates programmet vedr. Tematisk netværk inden for området Virtual Company and Modelbank...

  1. Taxation of virtual currency

    NARCIS (Netherlands)

    Bal, Aleksandra Marta

    2014-01-01

    The Information Age has created a new concept of money – virtual currencies existing solely in the cyberspace in the form of intangible computer code. The most prominent virtual currency scheme, Bitcoin, grabbed the public attention as its value skyrocketed at the beginning of 2012. Whereas Bitcoin

  2. VEM: Virtual Enterprise Methodology

    DEFF Research Database (Denmark)

    Tølle, Martin; Vesterager, Johan

    2003-01-01

    This chapter presents a virtual enterprise methodology (VEM) that outlines activities to consider when setting up and managing virtual enterprises (VEs). As a methodology the VEM helps companies to ask the right questions when preparing for and setting up an enterprise network, which works as a b...

  3. Representing Large Virtual Worlds

    NARCIS (Netherlands)

    Kol, T.R.

    2018-01-01

    The ubiquity of large virtual worlds and their growing complexity in computer graphics require efficient representations. This means that we need smart solutions for the underlying storage of these complex environments, but also for their visualization. How the virtual world is best stored and how

  4. The Erasmus Virtual Campus

    Science.gov (United States)

    Isakeit, D.

    2002-02-01

    The Erasmus Virtual Campus was inaugurated in September 2000 to bring together scientists and engineers interested in using the International Space Station and other facilities for their research. It also provides the foundation for creating Virtual Institutes in selected scientific disciplines. The current capabilities of the Campus are highlighted, along with plans for the future.

  5. Virtual Pediatric Hospital

    Science.gov (United States)

    ... Imaging Encyclopedia of Pediatric Thoracic Disease Virtual Pediatric Hospital is the Apprentice's Assistant™ Last revised on February ... GeneralPediatrics.com | PediatricEducation.org | SearchingPediatrics.com Virtual Pediatric Hospital is curated by Donna M. D'Alessandro, M. ...

  6. The Virtual Dressing Room

    DEFF Research Database (Denmark)

    Holte, Michael Boelstoft; Gao, Yi; Petersson, Eva

    2015-01-01

    This paper presents the design and evaluation of a usability and user experience test of a virtual dressing room. First, we motivate and introduce our recent developed prototype of a virtual dressing room. Next, we present the research and test design grounded in related usability and user experi...

  7. The issue of virtual teams

    OpenAIRE

    Fleiberková, Šárka

    2012-01-01

    The aim of this diploma thesis is the introduction of teamwork and virtual teams. The theoretical part of this work describes the birth of teamwork, its definition, properties, advantages and disadvantages. Next part of diploma thesis is dedicated to the virtual team. It describes the difference among virtual and traditional team, definition and characteristics of virtual team as well as tools that are used in virtual team. The second, practical, unit is focused on virtual teams at universiti...

  8. Organization Virtual or Networked?

    Directory of Open Access Journals (Sweden)

    Rūta Tamošiūnaitė

    2013-08-01

    Full Text Available Purpose—to present distinction between “virtual organization” and “networked organization”; giving their definitions.Design/methodology/approach—review of previous researches, systemic analyses of their findings and synthesis of distinctive characteristics of ”virtual organization” and “networked organization.”Findings—the main result of the research is key diverse features separating ”virtual organization” and ”networked organization.” Definitions of “virtual organization” and “networked organization” are presented.Originality/Value—distinction between “virtual organization” and “networked organization” creates possibilities to use all advantages of those types of organizations and gives foundation for deeper researches in this field.Research type: general review.

  9. Turbocharging Quantum Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Gamble, John King [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Nielsen, Erik [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Maunz, Peter Lukas Wilhelm [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Scholten, Travis L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Rudinger, Kenneth Michael [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography suffers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. We describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more effectively detect and characterize quantum noise using carefully tailored ensembles of input states.

  10. Virtual microscopy in virtual tumor banking

    NARCIS (Netherlands)

    Isabelle, M.; Teodorovic, I.; Oosterhuis, J. W.; Riegman, P. H. J.; Passioukov, A.; Lejeune, S.; Therasse, P.; Dinjens, W. N. M.; Lam, K. H.; Oomen, M. H. A.; Spatz, A.; Ratcliffe, C.; Knox, K.; Mager, R.; Kerr, D.; Pezzella, F.; van Damme, B.; van de Vijver, M.; van Boven, H.; Morente, M. M.; Alonso, S.; Kerjaschki, D.; Pammer, J.; López-Guerrero, J. A.; Llombart-Bosch, A.; Carbone, A.; Gloghini, A.; van Veen, E. B.

    2006-01-01

    Many systems have already been designed and successfully used for sharing histology images over large distances, without transfer of the original glass slides. Rapid evolution was seen when digital images could be transferred over the Internet. Nowadays, sophisticated virtual microscope systems can

  11. Virtual Machine Logbook - Enabling virtualization for ATLAS

    International Nuclear Information System (INIS)

    Yao Yushu; Calafiura, Paolo; Leggett, Charles; Poffet, Julien; Cavalli, Andrea; Frederic, Bapst

    2010-01-01

    ATLAS software has been developed mostly on CERN linux cluster lxplus or on similar facilities at the experiment Tier 1 centers. The fast rise of virtualization technology has the potential to change this model, turning every laptop or desktop into an ATLAS analysis platform. In the context of the CernVM project we are developing a suite of tools and CernVM plug-in extensions to promote the use of virtualization for ATLAS analysis and software development. The Virtual Machine Logbook (VML), in particular, is an application to organize work of physicists on multiple projects, logging their progress, and speeding up ''context switches'' from one project to another. An important feature of VML is the ability to share with a single 'click' the status of a given project with other colleagues. VML builds upon the save and restore capabilities of mainstream virtualization software like VMware, and provides a technology-independent client interface to them. A lot of emphasis in the design and implementation has gone into optimizing the save and restore process to makepractical to store many VML entries on a typical laptop disk or to share a VML entry over the network. At the same time, taking advantage of CernVM's plugin capabilities, we are extending the CernVM platform to help increase the usability of ATLAS software. For example, we added the ability to start the ATLAS event display on any computer running CernVM simply by clicking a button in a web browser. We want to integrate seamlessly VML with CernVM unique file system design to distribute efficiently ATLAS software on every physicist computer. The CernVM File System (CVMFS) download files on-demand via HTTP, and cache it locally for future use. This reduces by one order of magnitude the download sizes, making practical for a developer to work with multiple software releases on a virtual machine.

  12. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  13. Virtualization Security Combining Mandatory Access Control and Virtual Machine Introspection

    OpenAIRE

    Win, Thu Yein; Tianfield, Huaglory; Mair, Quentin

    2014-01-01

    Virtualization has become a target for attacks in cloud computing environments. Existing approaches to protecting the virtualization environment against the attacks are limited in protection scope and are with high overheads. This paper proposes a novel virtualization security solution which aims to provide comprehensive protection of the virtualization environment.

  14. Virtual Law -- Will real and virtual identity converge or diverge?

    OpenAIRE

    Dave Birch

    2003-01-01

    Some of the differences (conflicts, even) between real and virtual identity are thrown into sharp relief in the world of online games, where vast virtual worlds are already inhabited by millions of virtual characters. While they might be ÒonlyÓ games, they may contain some real insights into the future relationship between real and virtual identities.

  15. Virtual neutron scattering experiments

    DEFF Research Database (Denmark)

    Overgaard, Julie Hougaard; Bruun, Jesper; May, Michael

    2016-01-01

    We describe how virtual experiments can be utilized in a learning design that prepares students for hands-on experiments at large-scale facilities. We illustrate the design by showing how virtual experiments are used at the Niels Bohr Institute in a master level course on neutron scattering....... In the last week of the course, students travel to a large-scale neutron scattering facility to perform real neutron scattering experiments. Through student interviews and survey answers, we argue, that the virtual training prepares the students to engage more fruitfully with experiments by letting them focus...

  16. Virtual neutron scattering experiments

    DEFF Research Database (Denmark)

    Overgaard, Julie Hougaard; Bruun, Jesper; May, Michael

    2017-01-01

    We describe how virtual experiments can be utilized in a learning design that prepares students for hands-on experiments at large-scale facilities. We illustrate the design by showing how virtual experiments are used at the Niels Bohr Institute in a master level course on neutron scattering....... In the last week of the course, students travel to a large-scale neutron scattering facility to perform real neutron scattering experiments. Through student interviews and survey answers, we argue, that the virtual training prepares the students to engage more fruitfully with experiments by letting them focus...

  17. Virtual Museums as Educational Tool

    DEFF Research Database (Denmark)

    2007-01-01

    Virtual Museums as Educational Tool On this web site you will find a collection of resources on virtual museums. The web site is meant to be a knowledge base for people with interest in museums, virtuality and education, and how virtual museums may contribute to adult education and lifelong...

  18. Virtual reality simulator for vitreoretinal surgery using integrated OCT data

    OpenAIRE

    Kozak, Igor; Banerjee, Pat; Luo, Jia; Luciano, Cristian

    2014-01-01

    Igor Kozak,1 Pat Banerjee,2 Jia Luo,2 Cristian Luciano21King Khaled Eye Specialist Hospital, Vitreoretinal Division, Riyadh, Kingdom of Saudi Arabia; 2College of Engineering, University of Illinois at Chicago, Chicago, IL, USAAbstract: Operative practice using surgical simulators has become a part of training in many surgical specialties, including ophthalmology. We introduce a virtual reality retina surgery simulator capable of integrating optical coherence tomography (OCT) scans from real p...

  19. Virtual Organizations: An Overview

    Science.gov (United States)

    Nami, Mohammad Reza

    The need to remain competitive in the open market forces companies to concentrate on their core competencies while searching for alliances when additional skills or resources are needed to fulfill business opportunities. The changing business situation of companies and customer needs have motivated researchers to introduce Virtual Organization (VO) idea. A Virtual Organization is always a form of partnership and managing partners and handling partnerships are crucial. Virtual organizations are defined as a temporary collection of enterprises that cooperate and share resources, knowledge, and competencies to better respond to business opportunities. This paper presents base concepts of virtual organizations including properties, management concepts, operational concepts, and main issues in collaboration such as security and authentication.

  20. Virtual Factory Testbed

    Data.gov (United States)

    Federal Laboratory Consortium — The Virtual Factory Testbed (VFT) is comprised of three physical facilities linked by a standalone network (VFNet). The three facilities are the Smart and Wireless...

  1. Layered Augmented Virtuality

    National Research Council Canada - National Science Library

    Ahuja, G; Pacis, E. B; Sights, B; Fellars, D; Everett, H. R

    2007-01-01

    ... a virtual-world representation with information from onboard sensors and human input. Standard techniques for displaying information, such as embedding information icons from sensor payloads and external systems (e.g. other robots...

  2. Virtual Telescope Alignment System

    Data.gov (United States)

    National Aeronautics and Space Administration — Next-generation space telescopes require two spacecraft to fly in a coordinated fashion in space forming a virtual telescope. Achieving and maintaining this precise...

  3. Virtual Project Teams

    DEFF Research Database (Denmark)

    Bjørn, Pernille

    changes in both the technology structures and the collaborative practice; and 2) that establishing the social context within virtual project teams comprises negotiations of shared meaning bridging discontinuities typically associated with geographical distribution such as culture, work practices...... in virtual project teams whose members are spread across various geographical locations. The aim is to understand the specific factors, conditions and challenges underpinning such situations. This thesis describes, analyses and discusses three in-depth empirical studies on the practices and use of groupware...... technology in six real-life virtual teams, two in industry and four in education, applying interpretative research and action research methods. Two main lines of investigation are pursued: the first involves an examination of the organisational issues related to groupware adaptation in virtual project teams...

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  5. Virtual Reality Lab Assistant

    Science.gov (United States)

    Saha, Hrishikesh; Palmer, Timothy A.

    1996-01-01

    Virtual Reality Lab Assistant (VRLA) demonstration model is aligned for engineering and material science experiments to be performed by undergraduate and graduate students in the course as a pre-lab simulation experience. This will help students to get a preview of how to use the lab equipment and run experiments without using the lab hardware/software equipment. The quality of the time available for laboratory experiments can be significantly improved through the use of virtual reality technology.

  6. Virtual reality musical instruments

    DEFF Research Database (Denmark)

    Serafin, Stefania; Erkut, Cumhur; Kojs, Juraj

    2016-01-01

    The rapid development and availability of low cost technologies has created a wide interest in virtual reality (VR), but how to design and evaluate multisensory interactions in VR remains as a challenge. In this paper, we focus on virtual reality musical instruments, present an overview of our...... design and evaluation guidelines, and examine historical case studies. Our main contribution is to inform the design and evaluation of the future VRMIs and consider the challenges....

  7. Virtual Prototyping at CERN

    Science.gov (United States)

    Gennaro, Silvano De

    The VENUS (Virtual Environment Navigation in the Underground Sites) project is probably the largest Virtual Reality application to Engineering design in the world. VENUS is just over one year old and offers a fully immersive and stereoscopic "flythru" of the LHC pits for the proposed experiments, including the experimental area equipment and the surface models that are being prepared for a territorial impact study. VENUS' Virtual Prototypes are an ideal replacement for the wooden models traditionally build for the past CERN machines, as they are generated directly from the EUCLID CAD files, therefore they are totally reliable, they can be updated in a matter of minutes, and they allow designers to explore them from inside, in a one-to-one scale. Navigation can be performed on the computer screen, on a stereoscopic large projection screen, or in immersive conditions, with an helmet and 3D mouse. By using specialised collision detection software, the computer can find optimal paths to lower each detector part into the pits and position it to destination, letting us visualize the whole assembly probess. During construction, these paths can be fed to a robot controller, which can operate the bridge cranes and build LHC almost without human intervention. VENUS is currently developing a multiplatform VR browser that will let the whole HEP community access LHC's Virtual Protoypes over the web. Many interesting things took place during the conference on Virtual Reality. For more information please refer to the Virtual Reality section.

  8. Virtualization Technologies for the Business

    OpenAIRE

    Sabina POPESCU

    2011-01-01

    There is a new trend of change in today's IT industry. It's called virtualization. In datacenter virtualization can occur on several levels, but the type of virtualization has created this trend change is the operating system offered or server virtualization. OS virtualization technologies come in two forms. First, there is a software component that is used to simulate a natural machine that has total control of an operating system operating on the host equipment. The second is a hypervisor, ...

  9. Sobre objetos y experiencias virtuales

    OpenAIRE

    Pacho, Julián

    2009-01-01

    This paper analyses basic onto-epistemological properties of the virtual reality and suggests these theses. First, the virtual reality establishes a new nature; its essential feature is to be an organic world of emancipated techno-theories. Second, the virtual reality doesn’t substitutes the traditional book; it substitutes the world. Third, the experience of the world in the virtual reality excludes the natural world experience. Fourth, the ontology of virtual reality is build without an act...

  10. Virtual Machine in Automation Projects

    OpenAIRE

    Xing, Xiaoyuan

    2010-01-01

    Virtual machine, as an engineering tool, has recently been introduced into automation projects in Tetra Pak Processing System AB. The goal of this paper is to examine how to better utilize virtual machine for the automation projects. This paper designs different project scenarios using virtual machine. It analyzes installability, performance and stability of virtual machine from the test results. Technical solutions concerning virtual machine are discussed such as the conversion with physical...

  11. Virtual Data in CMS Production

    CERN Document Server

    Arbree, A; Bourilkov, D; Cavanaugh, R J; Graham, G; Katageri, S; Rodríguez, J; Voeckler, J; Wilde, M

    2003-01-01

    Initial applications of the GriPhyN Chimera Virtual Data System have been performed within the context of CMS Production of Monte Carlo Simulated Data. The GriPhyN Chimera system consists of four primary components: 1) a Virtual Data Language, which is used to describe virtual data products, 2) a Virtual Data Catalog, which is used to store virtual data entries, 3) an Abstract Planner, which resolves all dependencies of a particular virtual data product and forms a location and existence independent plan, 4) a Concrete Planner, which maps an abstract, logical plan onto concrete, physical grid resources accounting for staging in/out files and publishing results to a replica location service. A CMS Workflow Planner, MCRunJob, is used to generate virtual data products using the Virtual Data Language. Subsequently, a prototype workflow manager, known as WorkRunner, is used to schedule the instantiation of virtual data products across a grid.

  12. Virtual data in CMS production

    International Nuclear Information System (INIS)

    Arbree, A. et al.

    2004-01-01

    Initial applications of the GriPhyN Chimera Virtual Data System have been performed within the context of CMS Production of Monte Carlo Simulated Data. The GriPhyN Chimera system consists of four primary components: (1) a Virtual Data Language, which is used to describe virtual data products, (2) a Virtual Data Catalog, which is used to store virtual data entries, (3) an Abstract Planner, which resolves all dependencies of a particular virtual data product and forms a location and existence independent plan, (4) a Concrete Planner, which maps an abstract, logical plan onto concrete, physical grid resources accounting for staging in/out files and publishing results to a replica location service. A CMS Workflow Planner, MCRunJob, is used to generate virtual data products using the Virtual Data Language. Subsequently, a prototype workflow manager, known as WorkRunner, is used to schedule the instantiation of virtual data products across a grid

  13. Varieties of virtualization

    Science.gov (United States)

    Ellis, Stephen R.

    1991-01-01

    Natural environments have a content, i.e., the objects in them; a geometry, i.e., a pattern of rules for positioning and displacing the objects; and a dynamics, i.e., a system of rules describing the effects of forces acting on the objects. Human interaction with most common natural environments has been optimized by centuries of evolution. Virtual environments created through the human-computer interface similarly have a content, geometry, and dynamics, but the arbitrary character of the computer simulation creating them does not insure that human interaction with these virtual environments will be natural. The interaction, indeed, could be supernatural but it also could be impossible. An important determinant of the comprehensibility of a virtual environment is the correspondence between the environmental frames of reference and those associated with the control of environmental objects. The effects of rotation and displacement of control frames of reference with respect to corresponding environmental references differ depending upon whether perceptual judgement or manual tracking performance is measured. The perceptual effects of frame of reference displacement may be analyzed in terms of distortions in the process of virtualizing the synthetic environment space. The effects of frame of reference displacement and rotation have been studied by asking subjects to estimate exocentric direction in a virtual space.

  14. Virtual Library: An essential component of virtual education

    Directory of Open Access Journals (Sweden)

    M zarghani

    2015-06-01

    Full Text Available Abstract Introduction: Library is one of the essential elements of universities which provide some important educational needs of students. Virtual education can not be exempted and virtual libraries are important support for virtual training programs. The purpose of this study is to evaluate the viewpoint of administrators and students in virtual education centers about the virtual library, its role and resources. Methods: This study was a descriptive survey. The research instrument was a researcher made questionnaire that its validity and reliability was confirmed. The study population consisted of 19 virtual training centers in Tehran city. Out of 19 centers, simple randomized sampling was done in five Centers. The sample size was 360 students. Data collection was conducted online and descriptive statistics using SPSS 18 and Excel software were used. Results: The results showed that viewpoints of administrators and students about the mission and services of virtual libraries in some cases were similar and in some cases were different. One of the administrators’ reasons for setting up a virtual learning system was lifelong learning, and lack of knowledge about virtual libraries was the reason for inadequate use of virtual libraries. The best format of virtual library from the administrators’ and students’ viewpoint, was portal document format (PDF. Conclusion: One of the most important function of a virtual library, is lifelong learning and empowering users to provide information and educational needs. The main reason for not setting up a virtual library is t lack of knowledge about it.

  15. [Computed tomography and cranial paleoanthropology].

    Science.gov (United States)

    Cabanis, Emmanuel Alain; Badawi-Fayad, Jackie; Iba-Zizen, Marie-Thérèse; Istoc, Adrian; de Lumley, Henry; de Lumley, Marie-Antoinette; Coppens, Yves

    2007-06-01

    Since its invention in 1972, computed tomography (C.T.) has significantly evolved. With the advent of multi-slice detectors (500 times more sensitive than conventional radiography) and high-powered computer programs, medical applications have also improved. CT is now contributing to paleoanthropological research. Its non-destructive nature is the biggest advantage for studying fossil skulls. The second advantage is the possibility of image analysis, storage, and transmission. Potential disadvantages include the possible loss of files and the need to keep up with rapid technological advances. Our experience since the late 1970s, and a recent PhD thesis, led us to describe routine applications of this method. The main contributions of CT to cranial paleoanthropology are five-fold: --Numerical anatomy with rapid acquisition and high spatial resolution (helicoidal and multidetector CT) offering digital storage and stereolithography (3D printing). --Numerical biometry (2D and 3D) can be used to create "normograms" such as the 3D craniofacial reference model used in maxillofacial surgery. --Numerical analysis offers thorough characterization of the specimen and its state of conservation and/or restoration. --From "surrealism" to virtual imaging, anatomical structures can be reconstructed, providing access to hidden or dangerous zones. --The time dimension (4D imaging) confers movement and the possibility for endoscopic simulation and internal navigation (see Iconography). New technical developments will focus on data processing and networking. It remains our duty to deal respectfully with human fossils.

  16. Virtual-World Naturalism

    Directory of Open Access Journals (Sweden)

    Daniel Reynolds

    2010-07-01

    Full Text Available Sometimes a player will stray from the path described by a game, moving into new spaces, developing new possible modes of interaction, and often discovering the rougher edges of the game world, where physics models break down, textures become incongruous, and the pieces don’t quite fit together. Gameplay that seeks out these spaces and these phenomena, that searches for such clues to the underlying construction of the virtual environment, is a kind of virtual-world naturalism, at once a return to an investigative urge that has been subsumed to the exhaustive mapping and description of the real world and a form of resistance to the very idea of pre-defined paths of action, of externally imposed limits, in virtual worlds as well as in our own.

  17. Virtual Reality Musical Instruments

    DEFF Research Database (Denmark)

    Serafin, Stefania; Erkut, Cumhur; Kojs, Juraj

    2016-01-01

    The rapid development and availability of low-cost technologies have created a wide interest in virtual reality. In the field of computer music, the term “virtual musical instruments” has been used for a long time to describe software simulations, extensions of existing musical instruments......, and ways to control them with new interfaces for musical expression. Virtual reality musical instruments (VRMIs) that include a simulated visual component delivered via a head-mounted display or other forms of immersive visualization have not yet received much attention. In this article, we present a field...... overview of VRMIs from the viewpoint of the performer. We propose nine design guidelines, describe evaluation methods, analyze case studies, and consider future challenges....

  18. First Indico Virtual Event

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    The first Indico virtual event will take place on February 4th 15:00 and will focus on two main topics The release of Indico v1.2 The migration of the OO Indico backend database (ZODB) to a more standard DBMS It will be fully virtual using the CERN Vidyo service and will foster discussions between developers and administrators of Indico servers worldwide. Connections to the virtual room will be open, but attendees are encouraged to register to the event, in order to be informed of any changes in the organisation if any. If you would like to add a topic of discussion or propose yourself a contribution, please let us know at indico-team@cern.ch. Connection to Vidyo Vidyo connection details are available here CERN Vidyo service documentation can be found here First-time users are encouraged to try the service before connecting to the real event

  19. Virtual or Virtually U: Educational Institutions in Second Life

    OpenAIRE

    Nancy Jennings; Chris Collins

    2007-01-01

    Educational institutions are increasingly exploring the affordances of 3D virtual worlds for instruction and research, but few studies have been done to document current practices and uses of this emerging technology. This observational survey examines the virtual presences of 170 accredited educational institutions found in one such 3D virtual world called Second Life®, created by San- Francisco based Linden Lab®. The study focuses on what educational institutions look like in this virtual e...

  20. Coded Network Function Virtualization

    DEFF Research Database (Denmark)

    Al-Shuwaili, A.; Simone, O.; Kliewer, J.

    2016-01-01

    Network function virtualization (NFV) prescribes the instantiation of network functions on general-purpose network devices, such as servers and switches. While yielding a more flexible and cost-effective network architecture, NFV is potentially limited by the fact that commercial off-the-shelf ha......Network function virtualization (NFV) prescribes the instantiation of network functions on general-purpose network devices, such as servers and switches. While yielding a more flexible and cost-effective network architecture, NFV is potentially limited by the fact that commercial off...

  1. Virtual realities and education

    Directory of Open Access Journals (Sweden)

    Curcio Igor D.D.

    2016-12-01

    Full Text Available The purpose of this article is to highlight the state of the art of virtual reality, augmented reality, mixed reality technologies and their applications in formal education. We also present a selected list of case studies that prove the utility of these technologies in the context of formal education. Furthermore, as byproduct, the mentioned case studies show also that, although the industry is able to develop very advanced virtual environment technologies, their pedagogical implications are strongly related to a well-designed theoretical framework.

  2. Laboratorios virtuales colaborativos

    OpenAIRE

    Jara, Carlos A.; Candelas-Herías, Francisco A.; Torres, Fernando; Dormido Bencomo, Sebastián; Esquembre Martínez, Francisco

    2008-01-01

    Comunicación presentada en las XXIX Jornadas de Automática, Tarragona, 3-5 Septiembre 2008. El uso del laboratorio virtual (LV) como herramienta para el aprendizaje y experimentación práctica a distancia, cada vez es mayor en el entorno de educación superior. Este objeto de enseñanza virtual representa actualmente una revolución dentro del ámbito educativo, ya que permite adquirir al alumno habilidades prácticas desde cualquier lugar y en cualquier momento. Por otro lado, el desarrollo ...

  3. Virtual reality haptic dissection.

    Science.gov (United States)

    Erolin, Caroline; Wilkinson, Caroline; Soames, Roger

    2011-12-01

    This project aims to create a three-dimensional digital model of the human hand and wrist which can be virtually 'dissected' through a haptic interface. Tissue properties will be added to the various anatomical structures to replicate a realistic look and feel. The project will explore the role of the medical artist, and investigate cross-discipline collaborations in the field of virtual anatomy. The software will be used to train anatomy students in dissection skills, before experience on a real cadaver. The effectiveness of the software will be evaluated and assessed both quantitatively as well as qualitatively.

  4. Designing Virtual Learning Centers

    OpenAIRE

    Paquette, Gilbert

    2002-01-01

    - This paper is a pre-print version of the article whose definitive version can be found on http://www.springer.com/east/home/generic/search/results?SGWID=5-40109-22-2122620-0. Please cite the full reference when referring to the article. - This article is an extended version of a key-note presentation at the Ed-Media 2000 conference.; Virtual universities and work-place virtual institutes are seen, more and more, as a solution to the huge education demand of the knowledge society. I will lim...

  5. Virtual power plant auctions

    International Nuclear Information System (INIS)

    Ausubel, Lawrence M.; Cramton, Peter

    2010-01-01

    Since their advent in 2001, virtual power plant (VPP) auctions have been implemented widely. In this paper, we describe the simultaneous ascending-clock auction format that has been used for virtually all VPP auctions to date, elaborating on other design choices that most VPP auctions have had in common as well as discussing a few aspects that have varied significantly among VPP auctions. We then evaluate the various objectives of regulators in requiring VPP auctions, concluding that the auctions have been effective devices for facilitating new entry into electricity markets and for developing wholesale power markets. (author)

  6. Virtual power plant auctions

    Energy Technology Data Exchange (ETDEWEB)

    Ausubel, Lawrence M.; Cramton, Peter [Department of Economics, University of Maryland, College Park, MD 20742 (United States)

    2010-12-15

    Since their advent in 2001, virtual power plant (VPP) auctions have been implemented widely. In this paper, we describe the simultaneous ascending-clock auction format that has been used for virtually all VPP auctions to date, elaborating on other design choices that most VPP auctions have had in common as well as discussing a few aspects that have varied significantly among VPP auctions. We then evaluate the various objectives of regulators in requiring VPP auctions, concluding that the auctions have been effective devices for facilitating new entry into electricity markets and for developing wholesale power markets. (author)

  7. A duet (virtually)

    OpenAIRE

    Waeckerlé, Emmanuelle

    2008-01-01

    My practice-based research explores language and related issues of place and identity, such as personal cultural borders and digital-human relationships on the edges of language. With A duo and A duet (virtually) I attempt to push further the interplay between the virtual and the real, and between the visual and sonic representations of my voice. In 2002 I created a unique vocal and visual instrument that I call VINST3, which responds not only to touch but to mood and sensibility. It cons...

  8. Applied virtual reality

    International Nuclear Information System (INIS)

    Yule, I.Y.; Lee, D.J.

    1996-01-01

    To reduce plant down time during irradiated fuel cell dismantling at Torness Power Station, a new visualisation technique has been used for the manipulator. Complex computer graphics packages were used to provide a ''Virtual Reality'' environment which allowed the Irradiated Fuel Dismantling Cell to be simulated. Significant cost savings have been achieved due to reductions in lost output. The virtual reality environment is at present being extended to the design and deployment of a new manipulator for in-vessel inspection of the boiler. (UK)

  9. Positron emission tomography

    International Nuclear Information System (INIS)

    Iio, Masahiro

    1982-01-01

    Utilization of positron emission tomography was reviewed in relation to construction and planned construction of small-size medical cyclotrons, planned construction of positron cameras and utilization of short-lived radionuclides. (Chiba, N.)

  10. Cardiac positron emission tomography

    International Nuclear Information System (INIS)

    Eftekhari, M.; Ejmalian, G.

    2003-01-01

    Positron emission tomography is an intrinsically tool that provide a unique and unparalleled approach for clinicians and researchers to interrogate the heart noninvasively. The ability to label substances of physiological interest with positron-emitting radioisotopes has permitted insight into normal blood flow and metabolism and the alterations that occur with disease states. Positron emission tomography of the heart has evolved as a unique, noninvasive approach for the assessment of myocardial perfusion, metabolism, and function. Because of the intrinsic quantitative nature of positron emission tomography measurements as well as the diverse compounds that can be labeled with positron- emitting radioisotopes, studies with positron emission tomography have provided rich insight into the physiology of the heart under diverse conditions

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... imaging provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  12. Computed Tomography (CT) - Spine

    Science.gov (United States)

    ... the removal of fluid from a localized infection ( abscess ). In patients with narrowing ( stenosis ) of the spine ... Survey Images × Image Gallery Computed Tomography (CT or CAT scan) equipment View full size with caption Do ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  15. Computer tomography in otolaryngology

    Energy Technology Data Exchange (ETDEWEB)

    Gradzki, J. (Akademia Medyczna, Poznan (Poland))

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented.

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of a stroke. a stroke, especially with a new technique called Perfusion CT. brain tumors. enlarged brain ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  18. Informationally incomplete quantum tomography

    Science.gov (United States)

    Teo, Yong Siah; Řeháček, Jaroslav; Hradil, Zdenĕk

    2013-11-01

    In quantum-state tomography on sources with quantum degrees of freedom of large Hilbert spaces, inference of quantum states of light for instance, a complete characterization of the quantum states for these sources is often not feasible owing to limited resources. As such, the concepts of informationally incomplete state estimation becomes important. These concepts are ideal for applications to quantum channel/ process tomography, which typically requires a much larger number of measurement settings for a full characterization of a quantum channel. Some key aspects of both quantumstate and quantum-process tomography are arranged together in the form of a tutorial review article that is catered to students and researchers who are new to the field of quantum tomography, with focus on maximum-likelihood related techniques as instructive examples to illustrate these ideas.

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  20. Intracoronary optical coherence tomography

    DEFF Research Database (Denmark)

    Tenekecioglu, Erhan; Albuquerque, Felipe N; Sotomi, Yohei

    2017-01-01

    By providing valuable information about the coronary artery wall and lumen, intravascular imaging may aid in optimizing interventional procedure results and thereby could improve clinical outcomes following percutaneous coronary intervention (PCI). Intravascular optical coherence tomography (OCT)...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  3. Electrical Impedance Tomography Technology

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal for the Electrical Impedance Tomography Technology (EITT) project is to develop a reliable portable, lightweight device providing two-dimensional...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT scanning of the head is typically ...

  5. Introduction to Seismic Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, Charlotte Anne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-21

    Tomography is a method of obtaining an image of a 3d object by observing the behavior of energy transmissions through the object. The image is obtained by Interrogating the object with Energy sources at a variety of Locations and observing the Object’s effects on the energy at a Variety of sensors. Tomography was first Used to build 3-dimensional Scans through Human bodies. These Are called computed Tomographic (ct) scans.

  6. Universidades virtuales: ¿aprendizaje real?

    OpenAIRE

    Valenzuela González, Jaime R.

    2015-01-01

    1. Introducción; 2. Modalidades educativas; 3. Concepto y características de las universidades virtuales; 4. Un modelo de universidad virtual; 5. Universidades virtuales ¿aprendizaje real?; 6. Tensiones de las universidades virtuales; 7. Referencias

  7. Interlaboratory Comparison of a physical and a virtual assembly measured by CT

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo

    2018-01-01

    In a comparison including 20 laboratories, a physical as well as a virtual assembly provided as two data sets were used to investigate measuring and post-processing approaches in Computed Tomography, CT. Different procedures were used in the comparison including one simulating in-line measurement...

  8. Reduced iodinated contrast media for abdominal imaging by dual-layer spectral detector computed tomography for patients with kidney disease

    Directory of Open Access Journals (Sweden)

    Hirokazu Saito, MD

    2018-04-01

    Full Text Available Contrast-enhanced computed tomography using iodinated contrast media is useful for diagnosis of gastrointestinal diseases. However, contrast-induced nephropathy remains problematic for kidney diseases patients. Although current guidelines recommended the use of a minimal dose of contrast media necessary to obtain adequate images for diagnosis, obtaining adequate images with sufficient contrast enhancement is difficult with conventional computed tomography using reduced contrast media. Dual-layer spectral detector computed tomography enables the simultaneous acquisition of low- and high-energy data and the reconstruction of virtual monochromatic images ranging from 40 to 200 keV, retrospectively. Low-energy virtual monochromatic images can enhance the contrast of images, thereby facilitating reduced contrast media. In case 1, abdominal computed tomography angiography at 50 keV using 40% of the conventional dose of contrast media revealed the artery that was the source of diverticular bleeding in the ascending colon. In case 2, ischemia of the transverse colon was diagnosed by contrast-enhanced computed tomography and iodine-selective imaging using 40% of the conventional dose of contrast media. In case 3, advanced esophagogastric junctional cancer was staged and preoperative abdominal computed tomography angiography could be obtained with 30% of the conventional dose of contrast media. However, the texture of virtual monochromatic images may be a limitation at low energy. Keywords: Virtual monochromatic images, Contrast-induced nephropathy

  9. Corporate Training in Virtual Worlds

    OpenAIRE

    Charles Nebolsky; Nicholas K. Yee; Valery A. Petrushin; Anatole V. Gershman

    2004-01-01

    This paper presents virtual training worlds that are relatively low-cost distributed collaborative learning environments suitable for corporate training. A virtual training world allows a facilitator, experts and trainees communicating and acting in the virtual environment for practicing skills during collaborative problem solving. Using these environments is beneficial to both trainees and corporations. Two system prototypes – the sales training and the leadership training virtual worl...

  10. Corporate Training in Virtual Worlds

    Directory of Open Access Journals (Sweden)

    Charles Nebolsky

    2004-12-01

    Full Text Available This paper presents virtual training worlds that are relatively low-cost distributed collaborative learning environments suitable for corporate training. A virtual training world allows a facilitator, experts and trainees communicating and acting in the virtual environment for practicing skills during collaborative problem solving. Using these environments is beneficial to both trainees and corporations. Two system prototypes – the sales training and the leadership training virtual worlds – are described. The leadership training course design is discussed in details.

  11. Conventional versus virtual radiographs of the injured pelvis and acetabulum

    Energy Technology Data Exchange (ETDEWEB)

    Bishop, Julius A.; Rao, Allison J.; Pouliot, Michael A.; Bellino, Michael [Stanford University School of Medicine, Department of Orthopaedic Surgery, Stanford, CA (United States); Beaulieu, Christopher [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2015-09-15

    Evaluation of the fractured pelvis or acetabulum requires both standard radiographic evaluation as well as computed tomography (CT) imaging. The standard anterior-posterior (AP), Judet, and inlet and outlet views can now be simulated using data acquired during CT, decreasing patient discomfort, radiation exposure, and cost to the healthcare system. The purpose of this study is to compare the image quality of conventional radiographic views of the traumatized pelvis to virtual radiographs created from pelvic CT scans. Five patients with acetabular fractures and ten patients with pelvic ring injuries were identified using the orthopedic trauma database at our institution. These fractures were evaluated with both conventional radiographs as well as virtual radiographs generated from a CT scan. A web-based survey was created to query overall image quality and visibility of relevant anatomic structures. This survey was then administered to members of the Orthopaedic Trauma Association (OTA). Ninety-seven surgeons completed the acetabular fracture survey and 87 completed the pelvic fracture survey. Overall image quality was judged to be statistically superior for the virtual as compared to conventional images for acetabular fractures (3.15 vs. 2.98, p = 0.02), as well as pelvic ring injuries (2.21 vs. 1.45, p = 0.0001). Visibility ratings for each anatomic landmark were statistically superior with virtual images as well. Virtual radiographs of pelvic and acetabular fractures offer superior image quality, improved comfort, decreased radiation exposure, and a more cost-effective alternative to conventional radiographs. (orig.)

  12. Virtual Museum Learning

    Science.gov (United States)

    Prosser, Dominic; Eddisford, Susan

    2004-01-01

    This paper examines children's and adults' attitudes to virtual representations of museum objects. Drawing on empirical research data gained from two web-based digital learning environments. The paper explores the characteristics of on-line learning activities that move children from a sense of wonder into meaningful engagement with objects and…

  13. Laboratorio virtual visual

    OpenAIRE

    Torres Medina, Fernando

    2010-01-01

    Presentación del Laboratorio Virtual Visual destinado a la simulación de algoritmos de visión artificial y procesamiento de imágenes desarrollado en el Grupo de Automática, Robótica y Visión Artificial de la Universidad de Alicante.

  14. A virtual nuclear world?

    International Nuclear Information System (INIS)

    Salve, R.

    1998-01-01

    The way in which virtual reality technology has so dramatically developed over the last few years has opened up the possibility of its application to various industrial processes. This article describes the possible uses of such a technique in nuclear power plants in various phases such as design, construction, operation or dismantling. (Author)

  15. Virtual Libraries: Service Realities.

    Science.gov (United States)

    Novak, Jan

    This paper discusses client service issues to be considered when transitioning to a virtual library situation. Themes related to the transitional nature of society in the knowledge era are presented, including: paradox and a contradictory nature; blurring of boundaries; networks, systems, and holistic thinking; process/not product, becoming/not…

  16. Virtual Libraries: Service Realities.

    Science.gov (United States)

    Novak, Jan

    2002-01-01

    Discussion of changes in society that have resulted from information and communication technologies focuses on changes in libraries and a new market for library services with new styles of clients. Highlights client service issues to be considered when transitioning to a virtual library situation. (Author/LRW)

  17. CMS Virtual Tour Greece

    CERN Document Server

    CERN. Geneva

    2014-01-01

    More than 500 high-school students from 7 locations in Greece visit virtually the CMS experiment. Read more about this record-breaking event here: http://home.web.cern.ch/students-educators/updates/2014/02/students-visit-heart-cms-detector

  18. Adaptivenes in Virtual Teams

    NARCIS (Netherlands)

    S. Qureshi (Sadja); D. Vogel

    2000-01-01

    textabstractComputer supported teams are capturing the attention of academics and practitioners as organisations increasingly put them into practice as virtual teams. The practical relevance of current research into computer supported teams could be increased if greater attention is paid to

  19. Virtual Interactive Space (VIS)

    DEFF Research Database (Denmark)

    Brooks, Anthony Lewis

    2015-01-01

    This paper shares code that enables the making of a Virtual Interactive Space (VIS) where the skin of the invisible active sensor area is dynamically responsive to the velocity of a limb e.g. hand. Used in proprioception training of movement the patch is at the core of the author’s Reafferentation...

  20. Virtual machine performance benchmarking.

    Science.gov (United States)

    Langer, Steve G; French, Todd

    2011-10-01

    The attractions of virtual computing are many: reduced costs, reduced resources and simplified maintenance. Any one of these would be compelling for a medical imaging professional attempting to support a complex practice on limited resources in an era of ever tightened reimbursement. In particular, the ability to run multiple operating systems optimized for different tasks (computational image processing on Linux versus office tasks on Microsoft operating systems) on a single physical machine is compelling. However, there are also potential drawbacks. High performance requirements need to be carefully considered if they are to be executed in an environment where the running software has to execute through multiple layers of device drivers before reaching the real disk or network interface. Our lab has attempted to gain insight into the impact of virtualization on performance by benchmarking the following metrics on both physical and virtual platforms: local memory and disk bandwidth, network bandwidth, and integer and floating point performance. The virtual performance metrics are compared to baseline performance on "bare metal." The results are complex, and indeed somewhat surprising.

  1. Alice - The Virtual Secretary

    DEFF Research Database (Denmark)

    Hansen, Thomas K.

    2009-01-01

    of the primary ideas behind using animated agents is, quoting Wik and Granström (2007), to transform the well-known desktop metaphor of the PC, into a more human metaphor, thereby increasing the authenticity of our interaction with technology. At Knowledge Lab we have combined three different technologies...... in order to create Alice – The virtual secretary....

  2. Adapting Virtual Camera Behaviour

    DEFF Research Database (Denmark)

    Burelli, Paolo

    2013-01-01

    In a three-dimensional virtual environment aspects such as narrative and interaction completely depend on the camera since the camera defines the player’s point of view. Most research works in automatic camera control aim to take the control of this aspect from the player to automatically gen...

  3. Definition of Virtual Levels.

    Science.gov (United States)

    Shore, Bruce W.

    1979-01-01

    Presents an examination of graphical displays of solutions to time-dependent Schrodinger equation modeling a laser-excited three-level atom. It suggests that an energy level may be regarded as virtual when it is detuned from resonance by more than two Rabi frequencies. (Author/HM)

  4. Virtual Reality and Education.

    Science.gov (United States)

    Helsel, Sandra

    1992-01-01

    Intended to provide a basic understanding of virtual reality (VR) from an educational perspective, this article describes the debate between conceptual and technological orientations to VR; the conceptual orientation to VR; technological definitions of VR, artificial reality, and cyberspace; dimensions of VR; and VR's impact on education. (11…

  5. Virtual Bridge Design Challenge

    Science.gov (United States)

    Mitts, Charles R.

    2013-01-01

    This design/problem-solving activity challenges students to design a replacement bridge for one that has been designated as either structurally deficient or functionally obsolete. The Aycock MS Technology/STEM Magnet Program Virtual Bridge Design Challenge is an authentic introduction to the engineering design process. It is a socially relevant…

  6. Virtual Environments 2005

    DEFF Research Database (Denmark)

    This book contains the proceedings of the joint 9th International Immersive Projection Technologies Workshop and the 11th EUROGRAPHICS Virtual Environments Workshop (IPTEGVE). The event was held in Aalborg, Denmark the 6. and 7. October 2005. It was organized at the VR Media Lab, Aalborg Universi...

  7. A realidade do virtual

    Directory of Open Access Journals (Sweden)

    Eduardo Simonini Lopes

    2005-06-01

    Full Text Available O presente trabalho propõe discutir o conceito de virtual, tendocomo apoio as obras de Pierre Lévy, Jean Baudrillard e Gilles Deleuze.Entendemos que diferentes propostas de realidade do virtualsurgem baseando-se na abordagem de cada um desses autores. E cadauma dessas propostas abre novas perspectivas para o pensamentode enxergar e manipular o conceito de virtual. Partimos, então,neste trabalho, do entendimento do virtual conquanto entidadedesterritorializada (Lévy, 1998, seguindo até sua compreensãoenquanto espaço de potência (Deleuze, 1996. Cada uma dessasabordagens produz um modo de pensar, e, enquanto Lévy situa ovirtual como o espaço de representação da consciência humana,Deleuze já o trabalha como dimensão de intensidades não representacionais, promotora de contínua diferença. Construímos, assim, uma reflexão sobre o modo como alguns pensadores têm trabalhadoo conceito de virtual: utilizando-o como recognição e ignorandoseu entendimento como potência.

  8. A Virtual History of Mauritius

    African Journals Online (AJOL)

    admpather

    while offering numerous advantages over real reconstructions: Virtual Reconstructions. Historical reconstruction of the Aapravasi Ghat and the Grand Port Naval Battle will be considered and finally some preliminary work that has already been carried out will be presented. Keywords: Virtual Heritage, Virtual Reality, ...

  9. Team Development of Virtual Teams

    Science.gov (United States)

    Kim, Sooyoung

    2004-01-01

    Advanced technologies, globalization, the competitiveness of business, flexible working practices, and other rapid changes in the nature of work have all led to the booming of "virtual teams." This paper will provide an overview of virtual teams, including a description of their emergence, a definition and typology of the term "virtual team," an…

  10. Interacting with a Virtual Conductor

    NARCIS (Netherlands)

    Bos, P.; Reidsma, Dennis; Ruttkay, Z.M.; Nijholt, Antinus; Harper, R.; Rauterberg, M; Combetto, M.

    This paper presents a virtual embodied agent that can conduct musicians in a live performance. The virtual conductor conducts music specified by a MIDI file and uses input from a microphone to react to the tempo of the musicians. The current implementation of the virtual conductor can interact with

  11. Virtual Sensor Test Instrumentation

    Science.gov (United States)

    Wang, Roy

    2011-01-01

    Virtual Sensor Test Instrumentation is based on the concept of smart sensor technology for testing with intelligence needed to perform sell-diagnosis of health, and to participate in a hierarchy of health determination at sensor, process, and system levels. A virtual sensor test instrumentation consists of five elements: (1) a common sensor interface, (2) microprocessor, (3) wireless interface, (4) signal conditioning and ADC/DAC (analog-to-digital conversion/ digital-to-analog conversion), and (5) onboard EEPROM (electrically erasable programmable read-only memory) for metadata storage and executable software to create powerful, scalable, reconfigurable, and reliable embedded and distributed test instruments. In order to maximize the efficient data conversion through the smart sensor node, plug-and-play functionality is required to interface with traditional sensors to enhance their identity and capabilities for data processing and communications. Virtual sensor test instrumentation can be accessible wirelessly via a Network Capable Application Processor (NCAP) or a Smart Transducer Interlace Module (STIM) that may be managed under real-time rule engines for mission-critical applications. The transducer senses the physical quantity being measured and converts it into an electrical signal. The signal is fed to an A/D converter, and is ready for use by the processor to execute functional transformation based on the sensor characteristics stored in a Transducer Electronic Data Sheet (TEDS). Virtual sensor test instrumentation is built upon an open-system architecture with standardized protocol modules/stacks to interface with industry standards and commonly used software. One major benefit for deploying the virtual sensor test instrumentation is the ability, through a plug-and-play common interface, to convert raw sensor data in either analog or digital form, to an IEEE 1451 standard-based smart sensor, which has instructions to program sensors for a wide variety of

  12. Art in virtual reality 2010

    Science.gov (United States)

    Chang, Ben

    2010-01-01

    For decades, virtual reality artwork has existed in a small but highly influential niche in the world of electronic and new media art. Since the early 1990's, virtual reality installations have come to define an extreme boundary point of both aesthetic experience and technological sophistication. Classic virtual reality artworks have an almost mythological stature - powerful, exotic, and often rarely exhibited. Today, art in virtual environments continues to evolve and mature, encompassing everything from fully immersive CAVE experiences to performance art in Second Life to the use of augmented and mixed reality in public space. Art in Virtual Reality 2010 is a public exhibition of new artwork that showcases the diverse ways that contemporary artists use virtual environments to explore new aesthetic ground and investigate the continually evolving relationship between our selves and our virtual worlds.

  13. Integrated positron emission tomography/computed tomography for ...

    African Journals Online (AJOL)

    Integrated positron emission tomography/computed tomography for evaluation of mediastinal lymph node staging of non-small-cell lung cancer in a tuberculosisendemic area: A 5-year prospective observational study.

  14. Virtual Class Support at the Virtual Machine Level

    DEFF Research Database (Denmark)

    Nielsen, Anders Bach; Ernst, Erik

    2009-01-01

    This paper describes how virtual classes can be supported in a virtual machine.  Main-stream virtual machines such as the Java Virtual Machine and the .NET platform dominate the world today, and many languages are being executed on these virtual machines even though their embodied design choices...... conflict with the design choices of the virtual machine.  For instance, there is a non-trivial mismatch between the main-stream virtual machines mentioned above and dynamically typed languages.  One language concept that creates an even greater mismatch is virtual classes, in particular because fully...... general support for virtual classes requires generation of new classes at run-time by mixin composition.  Languages like CaesarJ and ObjectTeams can express virtual classes restricted to the subset that does not require run-time generation of classes, because of the restrictions imposed by the Java...

  15. Innovative application of virtual display technique in virtual museum

    Science.gov (United States)

    Zhang, Jiankang

    2017-09-01

    Virtual museum refers to display and simulate the functions of real museum on the Internet in the form of 3 Dimensions virtual reality by applying interactive programs. Based on Virtual Reality Modeling Language, virtual museum building and its effective interaction with the offline museum lie in making full use of 3 Dimensions panorama technique, virtual reality technique and augmented reality technique, and innovatively taking advantages of dynamic environment modeling technique, real-time 3 Dimensions graphics generating technique, system integration technique and other key virtual reality techniques to make sure the overall design of virtual museum.3 Dimensions panorama technique, also known as panoramic photography or virtual reality, is a technique based on static images of the reality. Virtual reality technique is a kind of computer simulation system which can create and experience the interactive 3 Dimensions dynamic visual world. Augmented reality, also known as mixed reality, is a technique which simulates and mixes the information (visual, sound, taste, touch, etc.) that is difficult for human to experience in reality. These technologies make virtual museum come true. It will not only bring better experience and convenience to the public, but also be conducive to improve the influence and cultural functions of the real museum.

  16. Ocean acoustic reverberation tomography.

    Science.gov (United States)

    Dunn, Robert A

    2015-12-01

    Seismic wide-angle imaging using ship-towed acoustic sources and networks of ocean bottom seismographs is a common technique for exploring earth structure beneath the oceans. In these studies, the recorded data are dominated by acoustic waves propagating as reverberations in the water column. For surveys with a small receiver spacing (e.g., ocean acoustic reverberation tomography, is developed that uses the travel times of direct and reflected waves to image ocean acoustic structure. Reverberation tomography offers an alternative approach for determining the structure of the oceans and advancing the understanding of ocean heat content and mixing processes. The technique has the potential for revealing small-scale ocean thermal structure over the entire vertical height of the water column and along long survey profiles or across three-dimensional volumes of the ocean. For realistic experimental geometries and data noise levels, the method can produce images of ocean sound speed on a smaller scale than traditional acoustic tomography.

  17. Practical Bayesian tomography

    Science.gov (United States)

    Granade, Christopher; Combes, Joshua; Cory, D. G.

    2016-03-01

    In recent years, Bayesian methods have been proposed as a solution to a wide range of issues in quantum state and process tomography. State-of-the-art Bayesian tomography solutions suffer from three problems: numerical intractability, a lack of informative prior distributions, and an inability to track time-dependent processes. Here, we address all three problems. First, we use modern statistical methods, as pioneered by Huszár and Houlsby (2012 Phys. Rev. A 85 052120) and by Ferrie (2014 New J. Phys. 16 093035), to make Bayesian tomography numerically tractable. Our approach allows for practical computation of Bayesian point and region estimators for quantum states and channels. Second, we propose the first priors on quantum states and channels that allow for including useful experimental insight. Finally, we develop a method that allows tracking of time-dependent states and estimates the drift and diffusion processes affecting a state. We provide source code and animated visual examples for our methods.

  18. The Herbert Virtual Museum

    Directory of Open Access Journals (Sweden)

    Panagiotis Petridis

    2013-01-01

    Full Text Available In recent years, virtual reality and augmented reality have emerged as areas of extreme interest as unique methods for visualising and interacting with digital museum artefacts in a different context, for example, as a virtual museum or exhibition, particularly over the Internet. Modern cultural heritage exhibitions have evolved from static to dynamic exhibitions and challenging explorations. This paper presents two different applications developed for the Herbert Museum and Art Gallery that make the user’s experience more immersive, engaging, and interactive. The first application utilizes mobile phone devices in order to enrich the visitors experience in the museum, and the second application is a serious game for cultural heritage and in particular for museum environments focusing on the younger visitors.

  19. Virtual reality systems

    Science.gov (United States)

    Johnson, David W.

    1992-01-01

    Virtual realities are a type of human-computer interface (HCI) and as such may be understood from a historical perspective. In the earliest era, the computer was a very simple, straightforward machine. Interaction was human manipulation of an inanimate object, little more than the provision of an explicit instruction set to be carried out without deviation. In short, control resided with the user. In the second era of HCI, some level of intelligence and control was imparted to the system to enable a dialogue with the user. Simple context sensitive help systems are early examples, while more sophisticated expert system designs typify this era. Control was shared more equally. In this, the third era of the HCI, the constructed system emulates a particular environment, constructed with rules and knowledge about 'reality'. Control is, in part, outside the realm of the human-computer dialogue. Virtual reality systems are discussed.

  20. Interactive Virtual Cinematography

    DEFF Research Database (Denmark)

    Burelli, Paolo

    , if the content of the game is procedurally generated, the designer might not have the necessary information to dene a priori the camera positions and movements. Automatic camera control aims to dene an abstraction layer that permits to control the camera using high-level and environment-independent rules...... is the process of visualising the content of a virtual environment by positioning and animating the virtual camera in the context of interactive applications such as a computer game. Camera placement and animation in games are usually directly controlled by the player or statically predened by designers. Direct...... control of the camera by the player increases the complexity of the interaction and reduces the designer's control on game storytelling. A completely designer-driven camera releases the player from the burden of controlling the point of view, but might generate undesired camera behaviours. Furthermore...

  1. Material and Virtuality

    DEFF Research Database (Denmark)

    Kruse Aagaard, Anders

    2015-01-01

    world and a physical world can interchange. The paper suggest an approach where an overlapping of virtuality and the tangible material output from digital fabrication machines create a method of using materialisation tools as instruments to connect the reality of materials and to an exploring process....... In this paper investigations in sheet steel form a substance of concrete experiments. The experiments set up shuttling processes in between different domains. Through those processes connections and intermingling between information from digital drawing and materiality is created. The dialogues established...... through these experiments is both tangible and directly connected to real actions in digital drawing or material processing but also the base for theoretical contemplations of the relation between virtual and actual and control and uncertainty....

  2. Virtual vitreoretinal surgery

    DEFF Research Database (Denmark)

    Vergmann, Anna Stage; Vestergaard, Anders Højslet; Grauslund, Jakob

    2017-01-01

    PURPOSE: To test the validity of the eyesi surgical simulator as an assessment tool in a virtual reality vitreoretinal training programme. METHODS: In collaboration with an experienced vitreoretinal surgeon, a virtual vitreoretinal training programme was composed on the eyesi surgical simulator......, software version 2.9.2 (VRmagic GmbH, Manheim, Germany). It was completed twice by three groups: 20 medical students, ten residents of ophthalmology and five trained vitreoretinal surgeons. The programme contained six training modules: navigation level 2 (Nav2), forceps training level 5 (ForT5), bimanual...... training level 3 (BimT3), laser coagulation level 3 (LasC3), posterior hyaloid level 3 (PostH3) and internal limiting membrane peeling level 3 (ILMP3). The scores in each module were assessed from two to five different factors (tissue treatment, efficiency, target achievement, instrument handling...

  3. Virtual reality at work

    Science.gov (United States)

    Brooks, Frederick P., Jr.

    1991-01-01

    The utility of virtual reality computer graphics in telepresence applications is not hard to grasp and promises to be great. When the virtual world is entirely synthetic, as opposed to real but remote, the utility is harder to establish. Vehicle simulators for aircraft, vessels, and motor vehicles are proving their worth every day. Entertainment applications such as Disney World's StarTours are technologically elegant, good fun, and economically viable. Nevertheless, some of us have no real desire to spend our lifework serving the entertainment craze of our sick culture; we want to see this exciting technology put to work in medicine and science. The topics covered include the following: testing a force display for scientific visualization -- molecular docking; and testing a head-mounted display for scientific and medical visualization.

  4. Applied virtual reality

    International Nuclear Information System (INIS)

    Yule, I.Y.; Lee, D.J.

    1996-01-01

    An early experience in deploying a manipulator to the Irradiated Fuel Dismantling Cell at Torness Power Station, quickly highlighted that special visualisation techniques were required to achieve a successful deployment and reduce plant system down time. This visualisation was later realised through the IGRIP software pakcage operating on a Silicon Graphics computing engine, which provides a 'Non-Immersive' Virtual Reality environment. Within this environment, models of the Irradiated Fuel Dismantling cell were generated along with a model of the manipulator, allowing manipulator deployment to the Irradiated Fuel Dismantling Cell be modelled. It is estimated that the first use of this new environment provided a significant saving to Scottish Nuclear in potential lost output. The use of this virtual reality environment is currently being extended into the design and deployment of a new manipulator for Torness in vessel inspection, the Boiler Inspection Manipulator. (author)

  5. Virtual team collaboration

    DEFF Research Database (Denmark)

    Bjørn, Pernille; Ngwenyama, Ojelanki

    2009-01-01

    as the foundation for building shared meaning at three levels. Also we investigate communication breakdowns that can be attributed to differences in lifeworld structures, organizational structures, and work process structures within a virtual team. We find that all communication breakdowns are manifested...... and experienced by the participants at the work process level; however, resolving breakdowns may require critical reflection at other levels. Where previous research argues that face-to-face interaction is an important variable for virtual team performance, our empirical observations reveal that communication......Managing international teams with geographically distributed participants is a complex task. The risk of communication breakdowns increases due to cultural and organizational differences grounded in the geographical distribution of the participants. Such breakdowns indicate general...

  6. Virtual personal assistant

    OpenAIRE

    Imrie, Peter; Bednar, Peter

    2013-01-01

    Abstract This report discusses ways in which new technology could be harnessed to create an intelligent Virtual Personal Assistant (VPA) with a focus on user-based information. It will look at examples of intelligent programs with natural language processing that are currently available, with different categories of support, and examine the potential usefulness of one specific piece of software as a VPA. This engages the ability to communicate socially through natural language processing, hol...

  7. Droni e turismo virtuale

    Directory of Open Access Journals (Sweden)

    Valeria Minucciani

    2015-08-01

    Full Text Available Virtual tourism has been through at least three generations.The first is a special form of e-commerce, and no doubt it has much changed the way you plan your travel. Second generation of virtual tourism has exploited georeference: the user can know the services offered nearby and, with appropriate apps and augmented reality, receive information about places.An important contribution has been made in this field by social media (see Flickr, as well as Tripadvisor. The third generation of virtual tourism even replaces the travel experience: first proposing visits in virtual worlds, then in the real world. That allows tourism to social classes that are excluded.The goal is to send in the real place an "avatar", that can perform what tourist wants. Some experiments have been recently performed with robots, here a visit by drones is proposed. In particular, indoor visits are difficult because it is necessary to re-create a microgeodetic reference system in a closed and confined environment, to allow remote control and to ensure the protection of the cultural property. It has also to be considered the issue of the size of the drone, its autonomy and shooting video (which must be 360 degrees and high definition.The real experience is irreplaceable, but this form of tourism can find many interesting applications and strengthen real tourism.In conclusion, we believe that not only this performances are now within the reach of our technical capabilities, but  they also represent an effective response to certain social and cultural issues. 

  8. Virtual nuclear weapons

    Energy Technology Data Exchange (ETDEWEB)

    Pilat, J.F.

    1997-08-01

    The term virtual nuclear weapons proliferation and arsenals, as opposed to actual weapons and arsenals, has entered in recent years the American lexicon of nuclear strategy, arms control, and nonproliferation. While the term seems to have an intuitive appeal, largely due to its cyberspace imagery, its current use is still vague and loose. The author believes, however, that if the term is clearly delineated, it might offer a promising approach to conceptualizing certain current problems of proliferation. The first use is in a reference to an old problem that has resurfaced recently: the problem of growing availability of weapon-usable nuclear materials in civilian nuclear programs along with materials made `excess` to defense needs by current arms reduction and dismantlement. It is argued that the availability of these vast materials, either by declared nuclear-weapon states or by technologically advanced nonweapon states, makes it possible for those states to rapidly assemble and deploy nuclear weapons. The second use has quite a different set of connotations. It is derived conceptually from the imagery of computer-generated reality. In this use, one thinks of virtual proliferation and arsenals not in terms of the physical hardware required to make the bomb but rather in terms of the knowledge/experience required to design, assemble, and deploy the arsenal. Virtual weapons are a physics reality and cannot be ignored in a world where knowledge, experience, materials, and other requirements to make nuclear weapons are widespread, and where dramatic army reductions and, in some cases, disarmament are realities. These concepts are useful in defining a continuum of virtual capabilities, ranging from those at the low end that derive from general technology diffusion and the existence of nuclear energy programs to those at the high end that involve conscious decisions to develop or maintain militarily significant nuclear-weapon capabilities.

  9. Virtual Reality Spectating

    OpenAIRE

    Hemb, Jan Greger

    2017-01-01

    The goal of this master was to assess and evaluate Virtual Reality (VR) spectating. VR spectating refers to spectating someone playing a game in VR. A series of spectating modes (mirroring, 3D and VR) was assessed in a series of experiments, and user testing sessions to determine the preferred mode for spectating VR content. A range of related topics were discussed as well, including spectator placement models, streamers core success values, and the projected success of VR as a platform. ...

  10. Virtual Environments Overview

    Science.gov (United States)

    2009-04-01

    digital form. McQuail , D (2000) McQuail’s Mass Communication Theory (4th edition), Sage, London, pp. 16-34. 5 2. AFFORDANCES OF VIRTUAL... S . (1991). “Grounding in Communication .” In Resnick, L.B., Levine, J., Teasley, S . (Eds.). Perspectives on Socially Shared Cognition. Washington DC...www.cia.gov/library/center-for-the-study-of-intelligence/csi-publications/books-and- monographs/analytic-culture-in-the-u- s -intelligence- community

  11. The virtual oil company

    International Nuclear Information System (INIS)

    Garibaldi, C.A.; Haney, R.M.; Ross, C.E.

    1995-01-01

    In anticipation of continuing declines in upstream activity levels over the next 15 years, the virtual oil company model articulates a vision of fewer, leaner, but financially stronger firms that concentrate only on their core competencies and outsource the rest through well-structured partnering arrangements. Freed from the ''clutter,'' these leading companies will be in better position to focus on those opportunities that offer the potential for renewed reserve and revenue growth

  12. Virtual private network (VPN)

    International Nuclear Information System (INIS)

    Caskey, Susan

    2006-01-01

    A virtual private network (VPN) is the essential security feature that allows remote monitoring systems to take advantage of the low communications cost of the internet. This paper introduces the VPN concept and summarizes the networking and security principles. The mechanics of security, for example, types of encryption and protocols for exchange of keys between partners, are explained. Important issues for partners in different countries include the interoperability and mutual accreditations of systems. (author)

  13. Droni e turismo virtuale

    Directory of Open Access Journals (Sweden)

    Valeria Minucciani

    2015-08-01

    Full Text Available Virtual tourism has been through at least three generations. The first is a special form of e-commerce, and no doubt it has much changed the way you plan your travel. Second generation of virtual tourism has exploited georeference: the user can know the services offered nearby and, with appropriate apps and augmented reality, receive information about places. An important contribution has been made in this field by social media (see Flickr, as well as Tripadvisor. The third generation of virtual tourism even replaces the travel experience: first proposing visits in virtual worlds, then in the real world. That allows tourism to social classes that are excluded. The goal is to send in the real place an "avatar", that can perform what tourist wants. Some experiments have been recently performed with robots, here a visit by drones is proposed. In particular, indoor visits are difficult because it is necessary to re-create a microgeodetic reference system in a closed and confined environment, to allow remote control and to ensure the protection of the cultural property. It has also to be considered the issue of the size of the drone, its autonomy and shooting video (which must be 360 degrees and high definition. The real experience is irreplaceable, but this form of tourism can find many interesting applications and strengthen real tourism. In conclusion, we believe that not only this performances are now within the reach of our technical capabilities, but  they also represent an effective response to certain social and cultural issues.

  14. Virtual Reality in Neurorehabilitation

    OpenAIRE

    Stasieńko Agnieszka; Sarzyńska-Długosz Iwona

    2016-01-01

    This article includes current information on the use of modern IT solutions and virtual-reality (VR)-based technologies in medical rehabilitation. A review of current literature on VR-based interventions and their indications, benefits and limitations in patients with nervous system diseases was conducted. The popularity of VR-based training as a tool used for rehabilitation of patients with acute and chronic deficits in both sensory-motor and cognitive disorders is increasing. Still, there i...

  15. Digital multilayer tomography

    International Nuclear Information System (INIS)

    Dueber, C.; Klose, K.J.; Thelen, M.

    1991-01-01

    With digital multilayer tomography a sequence of projection images is recorded by an image intensifier television system and stored as digital data during a linear run of a layer sequence. Using this data record, tomograms of the examined body region can be computed for any layer thickness by shifts and superimposition of the single projections later at a digital workstation. The qualities of digital and conventional tomograms are basically comparable. A drawback of digital tomography is its lower local resolution (512 x 512 image matrix), advantages are a lower radiation exposure, a shorter patient examination time, and the facilities of digital image processing (later processing, archive setup, transmission). (orig.) [de

  16. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  17. Tele Hyper Virtuality

    Science.gov (United States)

    Terashima, Nobuyoshi

    1994-01-01

    In the future, remote images sent over communication lines will be reproduced in virtual reality (VR). This form of virtual telecommunications, which will allow observers to engage in an activity as though it were real, is the focus of considerable attention. Taken a step further, real and unreal objects will be placed in a single space to create an extremely realistic environment. Here, imaginary and other life forms as well as people and animals in remote locations will gather via telecommunication lines that create a common environment where life forms can work and interact together. Words, gestures, diagrams and other forms of communication will be used freely in performing work. Actual construction of a system based on this new concept will not only provide people with experiences that would have been impossible in the past, but will also inspire new applications in which people will function in environments where it would have been difficult if not impossible for them to function until now. This paper describes Tele Hyper Virtuality concept, its definition, applications, the key technologies to accomplish it and future prospects.

  18. Medical Virtual Public Services

    Directory of Open Access Journals (Sweden)

    Iulia SURUGIU

    2008-01-01

    Full Text Available The healthcare enterprises are very disconnected. This paper intends to propose a solution that will provide citizens, businesses and medical enterprises with improved access to medical virtual public services. Referred medical services are based on existing national medical Web services and which support medically required services provided by physicians and supplementary health care practitioners, laboratory services and diagnostic procedures, clinics and hospitals’ services. Requirements and specific rules of these medical services are considered, and personalization of user preferences will to be supported. The architecture is based on adaptable process management technologies, allowing for virtual services which are dynamically combined from existing national medical services. In this way, a comprehensive workflow process is set up, allowing for service-level agreements, an audit trail and explanation of the process to the end user. The process engine operates on top of a virtual repository, providing a high-level semantic view of information retrieved from heterogeneous information sources, such as national sources of medical services. The system relies on a security framework to ensure all high-level security requirements are met. System’s architecture is business oriented: it focuses on Service Oriented Architecture - SOA concepts, asynchronously combining Web services, Business Process Management – BPM rules and BPEL standards.

  19. The virtual articulator.

    Science.gov (United States)

    Bisler, A; Bockholt, U; Kordass, B; Suchan, M; Voss, G

    2002-01-01

    The virtual articulator (VA) is intended for use as a tool for the analysis fo the complex static and dynamic occlusal relations. Its chief application is in individual diagnosis and the simulation of the mechanical articulator. As entry data, the VA requires digital, 3-dimensional representations of the jaws and patient-specific data on jaw movement. It then simulates jaw movement and provides a dynamic visualization of the occlusal contacts. If no patient-specific data are available, the modus operandi of the mechanical articulator can be simulated. Virtual reality (VR) techniques applied in computer-aided diagnosis are revolutionizing medical routine in many disciplines. Particularly in the field of dental engineering, VR combined with CAD/CAM technology has great potential in implant planning and design in terms of greater precision and shorter treatment duration. The geometry of teeth can be digitized, the implant models can be designed with specialized CAD systems, and the final implants can be manufactured with a CNC machine. In this context, the virtual articulator completes the digital manufacturing process.

  20. Virtual blood bank

    Directory of Open Access Journals (Sweden)

    Kit Fai Wong

    2011-01-01

    Full Text Available Virtual blood bank is the computer-controlled, electronically linked information management system that allows online ordering and real-time, remote delivery of blood for transfusion. It connects the site of testing to the point of care at a remote site in a real-time fashion with networked computers thus maintaining the integrity of immunohematology test results. It has taken the advantages of information and communication technologies to ensure the accuracy of patient, specimen and blood component identification and to enhance personnel traceability and system security. The built-in logics and process constraints in the design of the virtual blood bank can guide the selection of appropriate blood and minimize transfusion risk. The quality of blood inventory is ascertained and monitored, and an audit trail for critical procedures in the transfusion process is provided by the paperless system. Thus, the virtual blood bank can help ensure that the right patient receives the right amount of the right blood component at the right time.

  1. Virtual blood bank

    Science.gov (United States)

    Wong, Kit Fai

    2011-01-01

    Virtual blood bank is the computer-controlled, electronically linked information management system that allows online ordering and real-time, remote delivery of blood for transfusion. It connects the site of testing to the point of care at a remote site in a real-time fashion with networked computers thus maintaining the integrity of immunohematology test results. It has taken the advantages of information and communication technologies to ensure the accuracy of patient, specimen and blood component identification and to enhance personnel traceability and system security. The built-in logics and process constraints in the design of the virtual blood bank can guide the selection of appropriate blood and minimize transfusion risk. The quality of blood inventory is ascertained and monitored, and an audit trail for critical procedures in the transfusion process is provided by the paperless system. Thus, the virtual blood bank can help ensure that the right patient receives the right amount of the right blood component at the right time. PMID:21383930

  2. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  3. Children's (Pediatric) CT (Computed Tomography)

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  4. Realistic Visualization of Virtual Views and Virtual Cinema

    DEFF Research Database (Denmark)

    Livatino, Salvatore

    2005-01-01

    Realistic Virtual View Visualization is a new field of research which has received increasing attention in recent years. It is strictly related to the increased popularity of virtual reality and the spread of its applications, among which virtual photography and cinematography. The use of computer...... generated characters, "virtual actors", in the motion picture production increases every day. While the most known computer graphics techniques have largely been adopted successfully in nowadays fictions, it still remains very challenging to implement virtual actors which would resemble, visually, human...... is then gaining consensus: the augmented actor. Fundamental concepts and examples of methods proposed for realistic view synthesis, based on the transfer of photorealism from reference photographs to novel views, will be presented. The application of methods for realistic image synthesis to virtual cinematography...

  5. Framework for Virtual Cognitive Experiment in Virtual Geographic Environments

    OpenAIRE

    Fan Zhang; Mingyuan Hu; Weitao Che; Hui Lin; Chaoyang Fang

    2018-01-01

    Virtual Geographic Environment Cognition is the attempt to understand the human cognition of surface features, geographic processes, and human behaviour, as well as their relationships in the real world. From the perspective of human cognition behaviour analysis and simulation, previous work in Virtual Geographic Environments (VGEs) has focused mostly on representing and simulating the real world to create an ‘interpretive’ virtual world and improve an individual’s active cognition. In terms ...

  6. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  7. Framework for Virtual Cognitive Experiment in Virtual Geographic Environments

    Directory of Open Access Journals (Sweden)

    Fan Zhang

    2018-01-01

    Full Text Available Virtual Geographic Environment Cognition is the attempt to understand the human cognition of surface features, geographic processes, and human behaviour, as well as their relationships in the real world. From the perspective of human cognition behaviour analysis and simulation, previous work in Virtual Geographic Environments (VGEs has focused mostly on representing and simulating the real world to create an ‘interpretive’ virtual world and improve an individual’s active cognition. In terms of reactive cognition, building a user ‘evaluative’ environment in a complex virtual experiment is a necessary yet challenging task. This paper discusses the outlook of VGEs and proposes a framework for virtual cognitive experiments. The framework not only employs immersive virtual environment technology to create a realistic virtual world but also involves a responsive mechanism to record the user’s cognitive activities during the experiment. Based on the framework, this paper presents two potential implementation methods: first, training a deep learning model with several hundred thousand street view images scored by online volunteers, with further analysis of which visual factors produce a sense of safety for the individual, and second, creating an immersive virtual environment and Electroencephalogram (EEG-based experimental paradigm to both record and analyse the brain activity of a user and explore what type of virtual environment is more suitable and comfortable. Finally, we present some preliminary findings based on the first method.

  8. Celebral computerized tomography

    International Nuclear Information System (INIS)

    Lofteroed, B.; Sortland, O.

    1985-01-01

    Indications for cerebral computerized tomography (CT) and the diagnostic results from this examination are evaluated in 127 children. Pathological changes were found in 31 children, mostly based on such indications as increasing head size, suspicion of brain tumor, cerebral paresis, delayed psychomotor development and epileptic seizures. A list of indications for CT in children is given

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  11. Positron emission tomography

    NARCIS (Netherlands)

    Paans, AMJ

    Positron Emission Tomography (PET) is a method for determining biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides as C-11, N-13, O-15 and F-18 and by measuring the annihilation radiation using a

  12. Geodetic SAR Tomography

    NARCIS (Netherlands)

    Zhu, Xiao Xiang; Montazeri, Sina; Gisinger, Christoph; Hanssen, R.F.; Bamler, Richard

    2016-01-01

    In this paper, we propose a framework referred to as 'geodetic synthetic aperture radar (SAR) tomography' that fuses the SAR imaging geodesy and tomographic SAR inversion (TomoSAR) approaches to obtain absolute 3-D positions of a large amount of natural scatterers. The methodology is applied on

  13. Advances in neutron tomography

    Indian Academy of Sciences (India)

    Up to now the interaction of the neutron spin with magnetic fields in samples has not been applied to imaging techniques despite the fact that it was proposed many years ago. About ten years ago neutron depolarization as imaging signal for neutron radiography or tomography was demonstrated and in principle it works.

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  15. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  16. Optical Tomography in Combustion

    DEFF Research Database (Denmark)

    Evseev, Vadim

    . JQSRT 113 (2012) 2222, 10.1016/j.jqsrt.2012.07.015] included in the PhD thesis as an attachment. The knowledge and experience gained in the PhD project is the first important step towards introducing the advanced optical tomography methods of combustion diagnostics developed in the project to future...

  17. Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Andersen, Peter E.

    2015-01-01

    Optical coherence tomography (OCT) is a noninvasive imaging technique that provides real-time two- and three-dimensional images of scattering samples with micrometer resolution. Mapping the local reflectivity, OCT visualizes the morphology of the sample, in real time or at video rate. In addition...

  18. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  19. Computed tomography system

    International Nuclear Information System (INIS)

    Lambert, T.W.; Blake, J.E.

    1981-01-01

    This invention relates to computed tomography and is particularly concerned with determining the CT numbers of zones of interest in an image displayed on a cathode ray tube which zones lie in the so-called level or center of the gray scale window. (author)

  20. Holography and tomography

    International Nuclear Information System (INIS)

    Howells, M.

    1997-01-01

    This session includes a collection of outlines of pertinent information, diagrams, graphs, electron micrographs, and color photographs pertaining to historical aspects and recent advances in the development of X-ray Gabor Holography. Many of the photographs feature or pertain to instrumentation used in holography, tomography, and cryo-holography

  1. Immersive Virtual Reality for Visualization of Abdominal CT.

    Science.gov (United States)

    Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A; Bodenheimer, Robert E

    2013-03-28

    Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two-dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.

  2. Immersive virtual reality for visualization of abdominal CT

    Science.gov (United States)

    Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A.; Bodenheimer, Robert E.

    2013-03-01

    Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.

  3. Virtual reality technology and applications

    CERN Document Server

    Mihelj, Matjaž; Beguš, Samo

    2014-01-01

    As virtual reality expands from the imaginary worlds of science fiction and pervades every corner of everyday life, it is becoming increasingly important for students and professionals alike to understand the diverse aspects of this technology. This book aims to provide a comprehensive guide to the theoretical and practical elements of virtual reality, from the mathematical and technological foundations of virtual worlds to the human factors and the applications that enrich our lives: in the fields of medicine, entertainment, education and others. After providing a brief introduction to the topic, the book describes the kinematic and dynamic mathematical models of virtual worlds. It explores the many ways a computer can track and interpret human movement, then progresses through the modalities that make up a virtual world: visual, acoustic and haptic. It explores the interaction between the actual and virtual environments, as well as design principles of the latter. The book closes with an examination of diff...

  4. The ethnography of virtual reality

    Directory of Open Access Journals (Sweden)

    Gavrilović Ljiljana 1

    2004-01-01

    Full Text Available This paper discusses possible application of ethnographic research in the realm of virtual reality, especially in the relationship between cultures in virtual communities. This represents an entirely new area of ethnographic research and therefore many adjustments in the research design are needed for example, a development of a specific method of data gathering and tools for their verification. A virtual, cyber space is a version of social space more or less synchronous with it, but without the, "real", that is, physical presence of the people who create it. This virtual reality, defined and bounded by virtual space, is in fact real - and though we are not able to observe real, physical parameters of its existence, we can perceive its consequences. In sum, an innovative ethnographic research method is fully applicable for exploring the realm of virtual reality; in order to do so we need to expand, in addition to the new research design and methods, the field of science itself.

  5. Surgery applications of virtual reality

    Science.gov (United States)

    Rosen, Joseph

    1994-01-01

    Virtual reality is a computer-generated technology which allows information to be displayed in a simulated, bus lifelike, environment. In this simulated 'world', users can move and interact as if they were actually a part of that world. This new technology will be useful in many different fields, including the field of surgery. Virtual reality systems can be used to teach surgical anatomy, diagnose surgical problems, plan operations, simulate and perform surgical procedures (telesurgery), and predict the outcomes of surgery. The authors of this paper describe the basic components of a virtual reality surgical system. These components include: the virtual world, the virtual tools, the anatomical model, the software platform, the host computer, the interface, and the head-coupled display. In the chapter they also review the progress towards using virtual reality for surgical training, planning, telesurgery, and predicting outcomes. Finally, the authors present a training system being developed for the practice of new procedures in abdominal surgery.

  6. A Virtual Commissioning Learning Platform

    DEFF Research Database (Denmark)

    Mortensen, Steffen; Madsen, Ole

    2018-01-01

    Production Lab integrates a number of Industry 4.0 technologies for learning and research purposes. One of the many techniques is virtual commissioning. Virtual commissioning uses a virtual plant model and real controllers (PLCs) enabling a full emulation of the manufacturing system for verification. Virtual......The introduction of reconfigurable manufacturing systems (RMS), Industry 4.0 and the associated technologies requires the establishment of new competencies. Towards that goal, Aalborg University (AAU) has developed an Industry 4.0 learning factory, the AAU Smart Production Lab. The AAU Smart...... commissioning can lower the commissioning time up to 63%, allowing faster time to market. However, virtual commission is still missing industrial impact one of the reasons being lack of competencies and integration experiences. The paper presents the setup of the virtual commissioning learning platform...

  7. Virtual Reality for Anxiety Disorders

    Directory of Open Access Journals (Sweden)

    Elif Uzumcu

    2018-03-01

    Full Text Available Virtual reality is a relatively new exposure tool that uses three-dimensional computer-graphics-based technologies which allow the individual to feel as if they are physically inside the virtual environment by misleading their senses. As virtual reality studies have become popular in the field of clinical psychology in recent years, it has been observed that virtual-reality-based therapies have a wide range of application areas, especially on anxiety disorders. Studies indicate that virtual reality can be more realistic than mental imagery and can create a stronger feeling of ԰resenceԻ that it is a safer starting point compared to in vivo exposure; and that it can be applied in a more practical and controlled manner. The aim of this review is to investigate exposure studies based on virtual reality in anxiety disorders (specific phobias, panic disorder and agoraphobias, generalized anxiety disorder, social phobia, posttraumatic stress disorder and obsessive compulsive disorder.

  8. Virtual Vertical Aircraft Signal Training

    National Research Council Canada - National Science Library

    Norling, William

    1998-01-01

    .... Advances in virtual environments may provide a cost effective solution to the current live helicopter operations method of training, provided technical issues associated with hand and wand signal...

  9. Playful mediation and virtual sociality

    Directory of Open Access Journals (Sweden)

    Sihem NAJJAR

    2010-01-01

    Full Text Available As a space of sociability, virtual games, especially online role playing games, allow us to capture the interest of the playfulness in social life, but they are means by which users are able to experiment their relationship to others. The virtual games as a mediation device, constitute a "pretext" to forge friendships, develop love relationships, improve language skills, discover other cultures, etc. Based on a sociological survey of Tunisian Internet users (both sexes fans of virtual games we try to show how playful mediation is producing a multifaceted virtual sociality inherent in our contemporary societies.

  10. Virtual microscopy in pathology education.

    Science.gov (United States)

    Dee, Fred R

    2009-08-01

    Technology for acquisition of virtual slides was developed in 1985; however, it was not until the late 1990s that desktop computers had enough processing speed to commercialize virtual microscopy and apply the technology to education. By 2000, the progressive decrease in use of traditional microscopy in medical student education had set the stage for the entry of virtual microscopy into medical schools. Since that time, it has been successfully implemented into many pathology courses in the United States and around the world, with surveys indicating that about 50% of pathology courses already have or expect to implement virtual microscopy. Over the last decade, in addition to an increasing ability to emulate traditional microscopy, virtual microscopy has allowed educators to take advantage of the accessibility, efficiency, and pedagogic versatility of the computer and the Internet. The cost of virtual microscopy in education is now quite reasonable after taking into account replacement cost for microscopes, maintenance of glass slides, and the fact that 1-dimensional microscope space can be converted to multiuse computer laboratories or research. Although the current technology for implementation of virtual microscopy in histopathology education is very good, it could be further improved upon by better low-power screen resolution and depth of field. Nevertheless, virtual microscopy is beginning to play an increasing role in continuing education, house staff education, and evaluation of competency in histopathology. As Z-axis viewing (focusing) becomes more efficient, virtual microscopy will also become integrated into education in cytology, hematology, microbiology, and urinalysis.

  11. Virtual corporations, enterprise and organisation

    Directory of Open Access Journals (Sweden)

    Carmen RÃDUT

    2009-06-01

    Full Text Available Virtual organisation is a strategic paradigm that is centred on the use of information and ICT to create value. Virtual organisation is presented as a metamanagement strategy that has application in all value oriented organisations. Within the concept of Virtual organisation, the business model is an ICT based construct that bridges and integrates enterprise strategic and operational concerns. Firms try to ameliorate the impacts of risk and product complexity by forming alliances and partnerships with others to spread the risk of new products and new ventures and to increase organisational competence. The result is a networked virtual organization.

  12. The Virtual Dressing Room

    DEFF Research Database (Denmark)

    Holte, Michael Boelstoft

    2013-01-01

    kinds: (1) virtual real-time 2D image/video techniques, where the consumer gets to superimpose the clothes on their real-time video to visualize themselves wearing the clothes. (2) 2D and 3D mannequins, where a web-application uses the body measurements provided by the customer, to superimpose...... the standard sizes to fit a customized 2D or 3D mannequin before buying. (3) 3D camera and laser technologies which acquire 3D information of the costumer, enabling estimation of the body shape and measurements. Additionally, we conduct user studies to investigate the user behavior when buying clothes...

  13. Analizar las interacciones virtuales

    Directory of Open Access Journals (Sweden)

    Luis Gómez Encinas

    2003-11-01

    Full Text Available El propósito de este artículo es abordar una serie de cuestiones relacionadas con las interacciones virtuales. En concreto, nos centraremos en el IRC, los comúnmente llamados chats, para a partir de una crítica a ciertos posicionamientos analíticos, expresar la necesidad de indagar en esa faceta del ciberespacio desde el punto de vista de las relaciones sociales. Nuevas relaciones sociales, que acontecen en un espacio nuevo, y que por tanto se desarrollan bajo reglas y motivaciones que desbordan los viejos esquemas de observación.

  14. Grids, Clouds and Virtualization

    CERN Document Server

    Cafaro, Massimo

    2011-01-01

    Research into grid computing has been driven by the need to solve large-scale, increasingly complex problems for scientific applications. Yet the applications of grid computing for business and casual users did not begin to emerge until the development of the concept of cloud computing, fueled by advances in virtualization techniques, coupled with the increased availability of ever-greater Internet bandwidth. The appeal of this new paradigm is mainly based on its simplicity, and the affordable price for seamless access to both computational and storage resources. This timely text/reference int

  15. Interactive virtual optical laboratories

    Science.gov (United States)

    Liu, Xuan; Yang, Yi

    2017-08-01

    Laboratory experiences are essential for optics education. However, college students have limited access to advanced optical equipment that is generally expensive and complicated. Hence there is a need for innovative solutions to expose students to advanced optics laboratories. Here we describe a novel approach, interactive virtual optical laboratory (IVOL) that allows unlimited number of students to participate the lab session remotely through internet, to improve laboratory education in photonics. Although students are not physically conducting the experiment, IVOL is designed to engage students, by actively involving students in the decision making process throughout the experiment.

  16. Mobile Virtual Private Networking

    Science.gov (United States)

    Pulkkis, Göran; Grahn, Kaj; Mårtens, Mathias; Mattsson, Jonny

    Mobile Virtual Private Networking (VPN) solutions based on the Internet Security Protocol (IPSec), Transport Layer Security/Secure Socket Layer (SSL/TLS), Secure Shell (SSH), 3G/GPRS cellular networks, Mobile IP, and the presently experimental Host Identity Protocol (HIP) are described, compared and evaluated. Mobile VPN solutions based on HIP are recommended for future networking because of superior processing efficiency and network capacity demand features. Mobile VPN implementation issues associated with the IP protocol versions IPv4 and IPv6 are also evaluated. Mobile VPN implementation experiences are presented and discussed.

  17. The Virtual Monte Carlo

    CERN Document Server

    Hrivnacova, I; Berejnov, V V; Brun, R; Carminati, F; Fassò, A; Futo, E; Gheata, A; Caballero, I G; Morsch, Andreas

    2003-01-01

    The concept of Virtual Monte Carlo (VMC) has been developed by the ALICE Software Project to allow different Monte Carlo simulation programs to run without changing the user code, such as the geometry definition, the detector response simulation or input and output formats. Recently, the VMC classes have been integrated into the ROOT framework, and the other relevant packages have been separated from the AliRoot framework and can be used individually by any other HEP project. The general concept of the VMC and its set of base classes provided in ROOT will be presented. Existing implementations for Geant3, Geant4 and FLUKA and simple examples of usage will be described.

  18. Curso virtual de epilepsia

    OpenAIRE

    García Orjuela, Jemmy Xiomara

    2011-01-01

    El curso virtual de epilepsia es una herramienta informática dirigida a los estudiantes de pregrado de medicina de la Universidad Nacional de Colombia de sexto y séptimo semestre, resultado de la experiencia de la Liga Central Contra la Epilepsia y el esfuerzo mancomunado de los docentes del Departamento de Medicina Interna con la Unidad de Neurología, sus residentes e internos, y su finalidad es facilitar el autoaprendizaje y complementar los conceptos en el área en mención. Siendo de acces...

  19. Virtual Black Holes

    OpenAIRE

    Hawking, Stephen W.

    1995-01-01

    One would expect spacetime to have a foam-like structure on the Planck scale with a very high topology. If spacetime is simply connected (which is assumed in this paper), the non-trivial homology occurs in dimension two, and spacetime can be regarded as being essentially the topological sum of $S^2\\times S^2$ and $K3$ bubbles. Comparison with the instantons for pair creation of black holes shows that the $S^2\\times S^2$ bubbles can be interpreted as closed loops of virtual black holes. It is ...

  20. Virtual Paint for Android

    OpenAIRE

    Miloeski, Aleksandar

    2017-01-01

    The aim of this thesis is to create a functional application for the Android environment that allows the user to do simple virtual drawings without the use of the touch screen, but rather through hand motions caught by the camera. There is a variety of approaches to this end, which vary by complexity and performance. This piece of work attempts to find a middle ground among the existing algorithms, as well as to build on and improve them specifically for this particular task. The idea is ...

  1. Virtual Reality in Neurorehabilitation

    Directory of Open Access Journals (Sweden)

    Stasieńko Agnieszka

    2016-12-01

    Full Text Available This article includes current information on the use of modern IT solutions and virtual-reality (VR-based technologies in medical rehabilitation. A review of current literature on VR-based interventions and their indications, benefits and limitations in patients with nervous system diseases was conducted. The popularity of VR-based training as a tool used for rehabilitation of patients with acute and chronic deficits in both sensory-motor and cognitive disorders is increasing. Still, there is a need for large randomized trials to evaluate the efficacy and safety of VR-based rehabilitation techniques in different disease entities. .

  2. Realistic Virtual Cuts

    DEFF Research Database (Denmark)

    Laursen, Lasse Farnung

    Pigs and pig meat are major sources of income for Denmark. As one of the country's primary exports, it is no wonder that Denmark strives to maintain its competitive edge in the meat market. As part of an on-going effort to lower costs and maintain high standards, X-ray computed tomography (CT), a...... no doubt that this is just the tip of the iceberg in regards to modernizing and optimizing the way animal carcasses are processed and handled before becoming consumer goods....

  3. Virtual reality in advanced medical immersive imaging: a workflow for introducing virtual reality as a supporting tool in medical imaging

    KAUST Repository

    Knodel, Markus M.

    2018-02-27

    Radiologic evaluation of images from computed tomography (CT) or magnetic resonance imaging for diagnostic purposes is based on the analysis of single slices, occasionally supplementing this information with 3D reconstructions as well as surface or volume rendered images. However, due to the complexity of anatomical or pathological structures in biomedical imaging, innovative visualization techniques are required to display morphological characteristics three dimensionally. Virtual reality is a modern tool of representing visual data, The observer has the impression of being “inside” a virtual surrounding, which is referred to as immersive imaging. Such techniques are currently being used in technical applications, e.g. in the automobile industry. Our aim is to introduce a workflow realized within one simple program which processes common image stacks from CT, produces 3D volume and surface reconstruction and rendering, and finally includes the data into a virtual reality device equipped with a motion head tracking cave automatic virtual environment system. Such techniques have the potential to augment the possibilities in non-invasive medical imaging, e.g. for surgical planning or educational purposes to add another dimension for advanced understanding of complex anatomical and pathological structures. To this end, the reconstructions are based on advanced mathematical techniques and the corresponding grids which we can export are intended to form the basis for simulations of mathematical models of the pathogenesis of different diseases.

  4. On virtual displacement and virtual work in Lagrangian dynamics

    International Nuclear Information System (INIS)

    Ray, Subhankar; Shamanna, J

    2006-01-01

    The confusion and ambiguity encountered by students in understanding virtual displacement and virtual work is discussed in this paper. A definition of virtual displacement is presented that allows one to express them explicitly for holonomic (velocity independent), non-holonomic (velocity dependent), scleronomous (time independent) and rheonomous (time dependent) constraints. It is observed that for holonomic, scleronomous constraints, the virtual displacements are the displacements allowed by the constraints. However, this is not so for a general class of constraints. For simple physical systems, it is shown that the work done by the constraint forces on virtual displacements is zero. This motivates Lagrange's extension of d'Alembert's principle to a system of particles in constrained motion. However, a similar zero work principle does not hold for the allowed displacements. It is also demonstrated that d'Alembert's principle of zero virtual work is necessary for the solvability of a constrained mechanical problem. We identify this special class of constraints, physically realized and solvable, as the ideal constraints. The concept of virtual displacement and the principle of zero virtual work by constraint forces are central to both Lagrange's method of undetermined multipliers and Lagrange's equations in generalized coordinates

  5. THE USE OF VIRTUAL ETHNOGRAPHY THE USE OF VIRTUAL ETHNOGRAPHY

    Directory of Open Access Journals (Sweden)

    Kadriye UZUN

    2012-04-01

    Full Text Available 3D virtual worlds can and have been used as a meeting place for distance education courses. Virtual worlds allow for group learning of the kind enjoyed by students gathered in a virtual classroom, where they know they are in a communal space, they are aware of the social process of learning and are affected by the presence and behaviour of their fellow students and tutor.Traditional ethnography has been adjusted to virtual environments and much research on this issue has been carried out under the umbrella of virtual ethnography. The increase in diverse Internet applications can be pointed out as the cause of this inclination and increase.In this study, the authors explain the method of virtual ethnography in detail, inform about data gathering instruments such as participatory virtual observation, online and offline (face to face interviews touch upon ethical questions related to field studies and highlight the elements that call for attention in the use of virtual ethnography in distance education studies.

  6. Realidad Virtual: Potencial Educativo

    Directory of Open Access Journals (Sweden)

    Luz Santamaría Granados

    2013-08-01

    Full Text Available El grupo GIBRANT centró sus esfuerzos en la investigación de realidad virtual, al experimentar en el uso de herramientas del consorcio Web3D (VRML y X3D, para el diseño y modelamiento de mundos virtuales en 3D, así pudo evidenciar el trabajo de estudiantes y docentes en el proyecto USTA en 3D; como tambien en algunas prácticas de formación en colegios de educación media, que involucran el uso de TIC, en el desarrollo de competencias de ubicación espacial, trigonométrica y rotación de objetos; y la construcción de escenaios que afianzan el proceso de enseñanza - aprendizaje en cuanquier área del saber. Este articulo quiere hacer ver la facilidad y la potencialidad de las MTIC e invita a la comunidad de educacion básica y media a apropiarse de estas tecnologías para su propio beneficio.

  7. Grids, Clouds, and Virtualization

    Science.gov (United States)

    Cafaro, Massimo; Aloisio, Giovanni

    This chapter introduces and puts in context Grids, Clouds, and Virtualization. Grids promised to deliver computing power on demand. However, despite a decade of active research, no viable commercial grid computing provider has emerged. On the other hand, it is widely believed - especially in the Business World - that HPC will eventually become a commodity. Just as some commercial consumers of electricity have mission requirements that necessitate they generate their own power, some consumers of computational resources will continue to need to provision their own supercomputers. Clouds are a recent business-oriented development with the potential to render this eventually as rare as organizations that generate their own electricity today, even among institutions who currently consider themselves the unassailable elite of the HPC business. Finally, Virtualization is one of the key technologies enabling many different Clouds. We begin with a brief history in order to put them in context, and recall the basic principles and concepts underlying and clearly differentiating them. A thorough overview and survey of existing technologies provides the basis to delve into details as the reader progresses through the book.

  8. Virtual reality via photogrammetry

    Science.gov (United States)

    Zahrt, John D.; Papcun, George; Childers, Randy A.; Rubin, Naama

    1996-03-01

    We wish to walk into a photograph just as Alice walked into the looking glass. From a mathematical perspective, this problem is exceedingly ill-posed (e.g. Is that a large, distant object or a small, nearby object?). A human expert can supply a large amount of a priori information that can function as mathematical constraints. The constrained problem can then be attacked with photogrammetry to obtain a great deal of quantitative information which is otherwise only qualitatively apparent. The user determines whether the object to be analyzed contains two or three vanishing points, then selects an appropriate number of points from the photon to enable the code to compute the locations of the vanishing points. Using this information and the standard photogrammetric geometric algorithms, the location of the camera, relative to the structure, is determined. The user must also enter information regarding an absolute sense of scale. As the vectors from the camera to the various points chosen from the photograph are determined, the vector components (coordinates) are handed to a virtual reality software package. Once the objects are entered, the appropriate surfaces of the 3D object are `wallpapered' with the surface from the photograph. The user is then able to move through the virtual scene. A video will demonstrate our work.

  9. Analysis of the acceptance procedure and quality control a virtual simulation system; Analisis del procedimiento de aceptacion y control de calidad de un sistema de simulacion virtual

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Ruiz, C.; Pedrero de Aristizabal, D.; Jimenez Rojas, R.; Garcia Hernandez, M. J.; Ruiz Galan, G.; Ayala Lazaro, R.; Garcia Marcos, R.

    2011-07-01

    Acceptance has been made, determining the reference state, commissioning and implementation of control protocol virtual simulation system consists of an image acquisition unit of computerized tomography (CT), an independent external location laser locator and a simulation module associated with the existing scheduler for clinical dosimetry in radiotherapy. This paper summarizes the path followed in this process, together with the established procedure for periodic monitoring and analysis system of the results obtained in the two years of clinical and control.

  10. Positron emission tomography

    International Nuclear Information System (INIS)

    Yamamoto, Y.L.; Thompson, C.J.; Diksic, M.; Meyer, E.; Feindel, W.H.

    1984-01-01

    One of the most exciting new technologies introduced in the last 10 yr is positron emission tomography (PET). PET provides quantitative, three-dimensional images for the study of specific biochemical and physiological processes in the human body. This approach is analogous to quantitative in-vivo autoradiography but has the added advantage of permitting non-invasive in vivo studies. PET scanning requires a small cyclotron to produce short-lived positron emitting isotopes such as oxygen-15, carbon-11, nitrogen-13 and fluorine-18. Proper radiochemical facilities and advanced computer equipment are also needed. Most important, PET requires a multidisciplinary scientific team of physicists, radiochemists, mathematicians, biochemists and physicians. The most recent trends are reviewed in the imaging technology, radiochemistry, methodology and clinical applications of positron emission tomography. (author)

  11. Mathematical Methods in Tomography

    CERN Document Server

    Louis, Alfred; Natterer, Frank

    1991-01-01

    The conference was devoted to the discussion of present and future techniques in medical imaging, including 3D x-ray CT, ultrasound and diffraction tomography, and biomagnetic ima- ging. The mathematical models, their theoretical aspects and the development of algorithms were treated. The proceedings contains surveys on reconstruction in inverse obstacle scat- tering, inversion in 3D, and constrained least squares pro- blems.Research papers include besides the mentioned imaging techniques presentations on image reconstruction in Hilbert spaces, singular value decompositions, 3D cone beam recon- struction, diffuse tomography, regularization of ill-posed problems, evaluation reconstruction algorithms and applica- tions in non-medical fields. Contents: Theoretical Aspects: J.Boman: Helgason' s support theorem for Radon transforms-a newproof and a generalization -P.Maass: Singular value de- compositions for Radon transforms- W.R.Madych: Image recon- struction in Hilbert space -R.G.Mukhometov: A problem of in- teg...

  12. Controllable tomography phase microscopy

    Science.gov (United States)

    Xiu, Peng; Zhou, Xin; Kuang, Cuifang; Xu, Yingke; Liu, Xu

    2015-03-01

    Tomography phase microscopy (TPM) is a new microscopic method that can quantitatively yield the volumetric 3D distribution of a sample's refractive index (RI), which is significant for cell biology research. In this paper, a controllable TPM system is introduced. In this system a circulatory phase-shifting method and piezoelectric ceramic are used which enable the TPM system to record the 3D RI distribution at a more controllable speed, from 1 to 40 fps, than in the other TPM systems reported. The resolution of the RI distribution obtained by this controllable TPM is much better than that in images recorded by phase contrast microscopy and interference tomography microscopy. The realization of controllable TPM not only allows for the application of TPM to the measurement of kinds of RI sample, but also contributes to academic and technological support for the practical use of TPM.

  13. Highly resolving computerized tomography

    International Nuclear Information System (INIS)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions. (BWU) [de

  14. Reinforced concrete tomography

    International Nuclear Information System (INIS)

    Mariscotti, M.A.J.; Morixe, M.; Tarela, P.A.; Thieberger, P.

    1997-01-01

    In this paper we describe the technique of reinforced concrete tomography, its historical background, recent technological developments and main applications. Gamma radiation sensitive plates are imprinted with radiation going through the concrete sample under study, and then processed to reveal the presence of reinforcement and defects in the material density. The three dimensional reconstruction, or tomography, of the reinforcement out of a single gammagraphy is an original development alternative to conventional methods. Re-bar diameters and positions may be determined with an accuracy of ± 1 mm 0.5-1 cm, respectively. The non-destructive character of this technique makes it particularly attractive in cases of inhabited buildings and diagnoses of balconies. (author) [es

  15. Virtual Realities and the Future of Text.

    Science.gov (United States)

    Marcus, Stephen

    1992-01-01

    Discusses issues surrounding virtual reality and "virtual books." Suggests that those who are exploring the territory of virtual realities are already helping to expand and enrich expectations and visions for integrating technology into reading and writing. (RS)

  16. Training Spatial Knowledge Acquisition Using Virtual Environments

    National Research Council Canada - National Science Library

    Koh, Glenn

    1997-01-01

    .... Subjects were trained to recognize key features of a venue using one of: an immersive virtual environment, a nonimmersive virtual environment, an exocentric virtual model of the venue, and a walkthrough of the actual venue...

  17. Virtual Stationary Automata for Mobile Networks

    National Research Council Canada - National Science Library

    Dolev, Shlomi; Gilbert, Seth; Lahiani, Limor; Lynch, Nancy; Nolte, Tina

    2005-01-01

    We define a programming abstraction for mobile networks called the Virtual Stationary Automata programming layer, consisting of real mobile clients, virtual timed I/O automata called virtual stationary automata (VSAs...

  18. Virtual colonoscopy with electron beam CT: correlation with barium enema, colonoscopy and pathology

    International Nuclear Information System (INIS)

    Hong, Hye Suk; Kim, Min Jung; Chung, Jae Joon; Kim, Myeong Jin; Lee, Jong Tae; Yoo, Hyung Sik

    1998-01-01

    To perform virtual colonoscopy using electron beam tomography(EBT) in patients in whom a colonic mass was present, and to compare the results with those obtained using barium enema, colonoscopy and gross pathologic specimens. Materials and Methods : Ten patients in whom colonic masses were diagnosed by either barium enema or colonoscopy were involved in this study. There were nine cases of adenocarcinoma and one of tubulovillous adenoma. Using EBT preoperative abdominopelvic CT scans were performed. Axial scans were then three-dimensionally reconstructed to produce virtual colonoscopic images and were compared with barium enema, colonoscopy and gross pathologic specimens. Virtual colonoscopic images of the masses were classified as either 1)polyploid, 2)sessile,3)fungating, or 4)annular constrictive. We also determined whether ulcers were present within the lesions and whether there was obstruction. Results : After virtual colonoscopy, two lesions were classified as polyploid, one as sessile, five as fungating and two as annular constrictive. Virtual colonoscopic images showed good correlation with the findings of barium enema, colonoscopy and gross pathologic specimens. Three of six ulcerative lesions were observed on colonoscopy; in seven adenocarcinomas with partial or total luminal obstruction, virtual colonoscopy visualized the colon beyond the obstructed sites. In one case, barium contrast failed to pass through the obstructed portion and in six cases, the colonoscope similarly failed. Conclusion : Virtual colonoscopies correlated well with barium enema, colonoscopy and gross pathologic specimens. They provide three dimensional images of colonic masses and are helpful for the evaluation of obstructive lesions

  19. Stereoscopic virtual reality models for planning tumor resection in the sellar region

    Directory of Open Access Journals (Sweden)

    Wang Shou-sen

    2012-11-01

    Full Text Available Abstract Background It is difficult for neurosurgeons to perceive the complex three-dimensional anatomical relationships in the sellar region. Methods To investigate the value of using a virtual reality system for planning resection of sellar region tumors. The study included 60 patients with sellar tumors. All patients underwent computed tomography angiography, MRI-T1W1, and contrast enhanced MRI-T1W1 image sequence scanning. The CT and MRI scanning data were collected and then imported into a Dextroscope imaging workstation, a virtual reality system that allows structures to be viewed stereoscopically. During preoperative assessment, typical images for each patient were chosen and printed out for use by the surgeons as references during surgery. Results All sellar tumor models clearly displayed bone, the internal carotid artery, circle of Willis and its branches, the optic nerve and chiasm, ventricular system, tumor, brain, soft tissue and adjacent structures. Depending on the location of the tumors, we simulated the transmononasal sphenoid sinus approach, transpterional approach, and other approaches. Eleven surgeons who used virtual reality models completed a survey questionnaire. Nine of the participants said that the virtual reality images were superior to other images but that other images needed to be used in combination with the virtual reality images. Conclusions The three-dimensional virtual reality models were helpful for individualized planning of surgery in the sellar region. Virtual reality appears to be promising as a valuable tool for sellar region surgery in the future.

  20. Polychromatic diffraction contrast tomography

    International Nuclear Information System (INIS)

    King, A.; Reischig, P.; Adrien, J.; Peetermans, S.; Ludwig, W.

    2014-01-01

    This tutorial review introduces the use of polychromatic radiation for 3D grain mapping using X-ray diffraction contrast tomography. The objective is to produce a 3D map of the grain shapes and orientations within a bulk, millimeter-sized polycrystalline sample. The use of polychromatic radiation enables the standard synchrotron X-ray technique to be applied in a wider range of contexts: 1) Using laboratory X-ray sources allows a much wider application of the diffraction contrast tomography technique. 2) Neutron sources allow large samples, or samples containing high Z elements to be studied. 3) Applied to synchrotron sources, smaller samples may be treated, or faster measurements may be possible. Challenges and particularities in the data acquisition and processing, and the limitations of the different variants, are discussed. - Highlights: • We present a tutorial review of polychromatic diffraction contrast tomography techniques. • The use of polychromatic radiation allows the standard synchrotron DCT technique to be extended to a range of other sources. • The characteristics and limitations of all variants of the techniques are derived, discussed and compared. • Examples using laboratory X-ray and cold neutron radiation are presented. • Suggestions for the future development of these techniques are presented