WorldWideScience

Sample records for tomography virtual hysterosalpingography

  1. Multidetector computed tomography virtual hysterosalpingography in the investigation of the uterus and fallopian tubes

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Baronio, Mariano; Capunay, Carlos; Lopez, Elba Martin; Vallejos, Javier; Borghi, Mario; Sueldo, Carlos; Papier, Sergio

    2008-01-01

    Objective: To compare the efficacy of multidetector CT virtual hysterosalpingography (MDCT-VH) with conventional X-ray hysterosalpingography (HSG) in the evaluation of patients with diagnosis of infertility. Methods: Sixty patients with diagnosis of infertility scheduled to perform a HSG, were evaluated with 16-row (n = 50) and 64-row (n = 10) MDCT-VH. In 35 patients the examination was performed without a tenaculum. The HSGs were carried out using standard technique. The HSG and MDCT-VH findings were compared. The duration for both examinations and patient discomfort were documented. The sensitivity and specificity of MDCT-VH for the detection of uterine pathology and tubal obstruction were calculated using the exact binomial method. Agreement between the two methods was assessed by the Cohen's kappa method (k). Results: The mean duration for MDCT-VH (16 and 64-rows) was 5 ± 3 min, whereas for HSG was 28 ± 3. The MDCT-VH without a tenaculum was the procedure with less patient discomfort. Sensitivity, specificity and inter-method agreement for the detection of uterine pathology were 100%, 92% and k = 0.92 for 16-row MDCT-VH and 100%, 100% and k = 1 for 64-row MDCT-VH, respectively. Sensitivity and specificity for detection of tubal obstruction were 80% and 80% for 16-row MDCT-VH and 100% and 100% for 64-row MDCT-VH, respectively; inter-method agreement for the visualization of the tubes was k = 0.54 for 16-row MDCT-VH and k = 1 for 64-row MDCT-VH. Conclusion: This study demonstrated the feasibility of evaluating the female reproductive system by MDCT-VH. 64-Row MDCT-VH could be an alternative diagnostic technique in the infertility workup algorithm. A larger study is in progress to validate these encouraging results

  2. Multidetector computed tomography virtual hysterosalpingography in the investigation of the uterus and fallopian tubes

    Energy Technology Data Exchange (ETDEWEB)

    Carrascosa, Patricia [Diagnostico Maipu, Av. Maipu 1668, Vicente Lopez B1602ABQ, Buenos Aires (Argentina)], E-mail: patriciacarrascosa@diagnosticomaipu.com.ar; Baronio, Mariano [CEGYR, Viamonte 1438, Capital Federal C1055ABB (Argentina); Capunay, Carlos; Lopez, Elba Martin; Vallejos, Javier [Diagnostico Maipu, Av. Maipu 1668, Vicente Lopez B1602ABQ, Buenos Aires (Argentina); Borghi, Mario; Sueldo, Carlos; Papier, Sergio [CEGYR, Viamonte 1438, Capital Federal C1055ABB (Argentina)

    2008-09-15

    Objective: To compare the efficacy of multidetector CT virtual hysterosalpingography (MDCT-VH) with conventional X-ray hysterosalpingography (HSG) in the evaluation of patients with diagnosis of infertility. Methods: Sixty patients with diagnosis of infertility scheduled to perform a HSG, were evaluated with 16-row (n = 50) and 64-row (n = 10) MDCT-VH. In 35 patients the examination was performed without a tenaculum. The HSGs were carried out using standard technique. The HSG and MDCT-VH findings were compared. The duration for both examinations and patient discomfort were documented. The sensitivity and specificity of MDCT-VH for the detection of uterine pathology and tubal obstruction were calculated using the exact binomial method. Agreement between the two methods was assessed by the Cohen's kappa method (k). Results: The mean duration for MDCT-VH (16 and 64-rows) was 5 {+-} 3 min, whereas for HSG was 28 {+-} 3. The MDCT-VH without a tenaculum was the procedure with less patient discomfort. Sensitivity, specificity and inter-method agreement for the detection of uterine pathology were 100%, 92% and k = 0.92 for 16-row MDCT-VH and 100%, 100% and k = 1 for 64-row MDCT-VH, respectively. Sensitivity and specificity for detection of tubal obstruction were 80% and 80% for 16-row MDCT-VH and 100% and 100% for 64-row MDCT-VH, respectively; inter-method agreement for the visualization of the tubes was k = 0.54 for 16-row MDCT-VH and k = 1 for 64-row MDCT-VH. Conclusion: This study demonstrated the feasibility of evaluating the female reproductive system by MDCT-VH. 64-Row MDCT-VH could be an alternative diagnostic technique in the infertility workup algorithm. A larger study is in progress to validate these encouraging results.

  3. Hysterosalpingography

    Science.gov (United States)

    ... For Patients Search FAQs Hysterosalpingography Page Navigation ▼ ACOG Pregnancy Book Hysterosalpingography Patient Education FAQs Hysterosalpingography Patient Education Pamphlets - Spanish Hysterosalpingography FAQ143, ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... Hysterosalpingography Hysterosalpingography uses a real-time form of x-ray called fluoroscopy to examine the uterus and fallopian ... is Hysterosalpingography? Hysterosalpingography, also called uterosalpingography, is an x-ray examination of a woman's uterus and fallopian tubes ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... masses, adhesions and uterine fibroids. Hysterosalpingography can occasionally open blocked fallopian tubes to allow the patient to ... carrying a fetus to term. Hysterosalpingography can occasionally open fallopian tubes that are blocked allowing the patient ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... Index A-Z Hysterosalpingography Hysterosalpingography uses a real-time form of x-ray called fluoroscopy to examine ... or an untreated sexually transmitted disease at the time of the procedure. On the night before the ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Hysterosalpingography Hysterosalpingography uses a ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. top of page What are the limitations of Hysterosalpingography? Hysterosalpingography only sees ...

  9. Hysterosalpingography

    International Nuclear Information System (INIS)

    Barbosa, J.R.; Barbosa, A.A.R.; Martins, A. Andre; Botter, L.C.; Barbosa, N.R.; Milano Filho, D.

    1987-01-01

    Several radiographics records with typical roentgen features in hysterosalpingography are presented. Congenital anomalies, myomas, polypus, hyperplasia of endometrium, adenomyosis, synechias, uterine carcinoma, tuba uterine and cervical canal alterations, caesarean section are briefly discussed. (M.A.C.) [pt

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... and to determine the presence and severity of these abnormalities, including: Tumor masses Adhesions Uterine fibroids Hysterosalpingography ... images are digital files that are stored electronically. These stored images are easily accessible and are frequently ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... called fluoroscopy to examine the uterus and fallopian tubes of a woman who is having difficulty becoming ... uterine fibroids. Hysterosalpingography can occasionally open blocked fallopian tubes to allow the patient to become pregnant afterwards. ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... the procedure? Hysterosalpingography is primarily used to examine women who have difficulty becoming pregnant by allowing the ... that might interfere with the x-ray images. Women should always inform their physician and x-ray ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... Hysterosalpingography, also called uterosalpingography, is an x-ray examination of a woman's uterus and fallopian tubes that ... look like? The equipment typically used for this examination consists of a radiographic table, one or two ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers top of page ... related to Hysterosalpingography Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... of tumor masses, adhesions and uterine fibroids. Hysterosalpingography can occasionally open blocked fallopian tubes to allow the ... the uterine or peritoneal (abdominal) cavity . The procedure can be used to investigate repeated miscarriages that result ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... Safety Images related to Hysterosalpingography Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... hysterosalpingography, including, but not limited to, low or abnormal sperm count or the inability of a fertilized ... in X-Ray and CT Exams Contrast Materials Abnormal Vaginal Bleeding Cervical Cancer Endometrial Cancer X-ray, ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... function. top of page What are some common uses of the procedure? Hysterosalpingography is primarily used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Hysterosalpingography is a minimally invasive procedure with rare ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... information on a variety of abnormalities that cause infertility or problems carrying a fetus to term. Hysterosalpingography ... structures may be evaluated with MRI or ultrasound. Infertility problems may be from causes not evaluated with ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Hysterosalpingography is a minimally invasive procedure with ... in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer ...

  2. 64-Row multidetector CT virtual hysterosalpingography. Findings in 2500 patients

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Capunay, Carlos; Baronio, Mariano; Vallejos, Javier; Papier, Sergio; Carrascosa, Jorge

    2011-01-01

    Objective. To depict typical features of virtual hysterosalpingography (VHSG) in infertile patients. Material and methods: 2500 VHSG performed using a 64-row MOCT were evaluated. Results: Cervical abnormalities visualized corresponded to parietal irregularities (21%); thickened folds (9%); polyps (11%); diverticula (5%); cervical strictures (8%), and synechiae (1.5%). At the level of uterine cavity, polyps (44%); submucous myomas (8%); intramural and subserosal fibroids (11%); synechiae (10%); malformations (10%); adenomyosis (4%), and cesarean section scar (3%). Unilateral hydrosalpinx (7%) and bilateral hydrosalpinx (2%). Tubal obstruction was reported in 6% of cases. The average radiation dose was 0.94 mSv. Eighty-four percent of the patients reported mild pain or no postoperative discomfort. Conclusions: The virtual hysterosalpingography allowed a proper assessment of the internal genital organs, providing useful diagnostic information on infertility and other gynecological disorders. It constitutes a virtually painless, low-dose radiation technique, besides being well tolerated by patients

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... procedure work? How is the procedure performed? What will I experience during and after the procedure? Who interprets the results and how do I get them? What are the benefits vs. risks? What are the limitations of Hysterosalpingography? ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... Wear loose, comfortable clothing and leave jewelry at home. You may be asked to wear a gown. What is Hysterosalpingography? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  5. Virtual electrical capacitance tomography sensor

    International Nuclear Information System (INIS)

    Li, Y; Yang, W Q

    2005-01-01

    Electrical capacitance tomography (ECT) is an effective technique for elucidating the distribution of dielectric materials inside closed pipes or vessels. This paper describes a virtual electrical capacitance tomography (VECT) system, which can simulate a range of sensor and hardware configurations and material distributions. A selection of popular image reconstruction algorithms has been made available and image error and capacitance error tools enable their performance to be evaluated and compared. Series of frame-by-frame results can be stored for simulating real-time dynamic flows. The system is programmed in Matlab with DOS functions. It is convenient to use and low-cost to operate, providing an effective tool for engineering experiment

  6. Virtual computed tomography cystoscopy in bladder pathologies

    International Nuclear Information System (INIS)

    Arslan, Halil; Ceylan, Kadir; Harman, Mustafa; Yilmaz, Yuksel; Temizoz, Osman; Can, Saban

    2006-01-01

    Objective: assessed the usefulness of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with different urinary bladder pathologies compared to the conventional cystoscopy.Materials and methods: eighteen patients with different bladder pathologies, which consisted of 11 tumors, 3 diverticula, 2 trabecular changes and 2 stones, were assessed with conventional cystoscopy and virtual CT cystoscopy. The results of virtual CT cystoscopy were compared with the findings of conventional cystoscopy. We determined the detection rate and positive predictive value of CT imaging based virtual cystoscopy in the diagnosis of urinary bladder lesions. Results: CT scanning was well tolerated by all patients, and no complications occurred. Images in 16 (88%) of the 18 virtual cystoscopic examinations were either of excellent or good quality. All tumors except one, 2 trabecular changes and 2 stones were characterized with similar findings in the both of methods. The masses ranged from 0.4 to 7.0 cm in diameter. While conventional cystoscopy could not evaluate interior part of the diverticulum, virtual CT cystoscopy could demonstrate clearly within it. There were no false-positive findings in our series. Conclusion: virtual CT cystoscopy is a promising technique to be used in the detection of bladder lesions. It should be considered especially at the evaluation of bladder diverticula. In the future, it may be possible or even advantageous to incorporate into the imaging algorithm for evaluation of bladder lesion. (author)

  7. Patient dosimetry in hysterosalpingography

    International Nuclear Information System (INIS)

    Khoury, H.J.; Maia, A.; Oliveira, M.; Kramer, R.; Drexler, G.

    2001-01-01

    The objectives of this study were to determine the entrance surface dose to the patient and to estimate the dose to the uterus and ovaries due to hysterosalpingography (HSG) diagnostic examinations performed in Recife-Pe, Brazil. The entrance doses were measured using four thermoluminescent dosimeters per patient, attached to anatomical landmarks on the patient's skin. The study was carried out on 25 patients between 21 and 45 years of age who underwent the HSG examinations in two training hospitals and one private radiodiagnostic institute. The number of exposures performed ranged from 4 to 15 radiographs per patient measured. Entrance surface doses varied between 4.99 and 36.6 mGy, with an average of 12.6mGy. The doses to the ovaries and uterus ranged from 0.80 mGy to 5.8 mGy and 1.10mGy to 8.05 mGy, respectively. (author)

  8. Radiogenic risks from hysterosalpingography

    International Nuclear Information System (INIS)

    Perisinakis, Kostas; Damilakis, John; Theocharopoulos, Nicholas; Grammatikakis, John; Gourtsoyiannis, Nicholas

    2003-01-01

    The aim of this study was to determine ovarian dose, effective dose and associated radiogenic risks from hysterosalpingography (HSG), and to provide data for the estimation of radiogenic risks related to HSG studies performed in any laboratory. The fluoroscopy time, number of radiographs taken and entrance surface dose were measured in a series of 78 consecutive patients undergoing HSG as part of their infertility work-up. Organ-dose values per radiograph and per minute of fluoroscopy were separately determined using an anthropomorphic phantom and thermoluminescence dosimetry. The radiogenic risk for deleterious effects on a possible future embryo and the radiogenic risk for cancer induction on the patient undergoing HSG were estimated. The average HSG procedure in our laboratory involves a mean fluoroscopic time of 0.3 min and a mean number of radiographs of 3.2. The dose to female gonads from an average HSG procedure was 2.7 mGy and the patient effective dose was 1.2 mSv. The risk for radiogenic anomalies in a future embryo of the woman undergoing an average HSG procedure and the risk for radiogenic fatal cancer induction in the exposed woman were estimated to be less than 10 -3 of the correspondent nominal risks. Radiation risks from a typical HSG are low, but they may be elevated if fluoroscopic and/or radiographic exposures are prolonged for any reason. Present data allow the estimation of radiogenic risks associated with HSG procedures performed in other laboratories with use of different equipment, screening time and number of radiographs taken. (orig.)

  9. Efficacy of virtual computerized tomography laparoscopy for retroperitoneoscopic nephrectomy

    International Nuclear Information System (INIS)

    Shigeta, Masanobu; Kadonishi, Yuichi; Yasumoto, Hiroaki; Mita, Koji; Usui, Tsuguru; Marukawa, Kazushi

    2004-01-01

    Retroperitoneoscopic nephrectomy is less invasive than open nephrectomy, and is an alternative surgical procedure for renal tumors and upper urothelial tumors. We evaluated the efficacy of virtual computerized tomography laparoscopy (VCTL) as a navigator for retroperitoneoscopic nephrectomy to ascertain the correct anatomy of the renal hilum pre-operatively under the retroperitoneoscopic view. Seventy-three kidneys with localized renal tumors (n=44), upper urothelial tumors (n=23), or benign renal disease (n=6) underwent multidetector-row CT. VCTL was carried out by the volume-rendered technique. The findings were compared with those of real retroperitoneoscopy. After the operation, each operator scored 1 to 5 in evaluating the usefulness of virtual retroperitoneoscopy (score 5 indicated very useful). The percentages of renal arteries depicted by VCTL compared with those noted during real surgery were 93% for kidneys with renal tumors, 100% for upper urothelial tumors and 83% for benign renal disease. Two renal arteries of 2 kidneys were not detected by virtual imaging. These were about 1 mm in diameter and directly branched from the aorta, however retroperitoneoscopic nephrectomy was performed uneventfully. VCTL depicted all the renal veins. The anatomy of the renal hilum seen on VCTL and real retroperitoneoscopy was identical, without the minor angle deviation caused by drawing the kidney during the operation. The average score for the usefulness of VCTL was 4.1, ranging from 3 to 5. The accurate surgical anatomy of the renal hilum could be predicted in almost all patients pre-operatively. VCTL is an excellent navigator for retroperitoneoscopic nephrectomy. (author)

  10. Hysterosalpingography: analysis of 473 abnormal examinations

    International Nuclear Information System (INIS)

    Petta, C.A.; Costa-Paiva, L.H.S. da; Pinto-Neto, A.M.; Martins, R.; Souza, G.A.

    1990-01-01

    The authors reviewed the reports of 4/3 abnormal hysterosalpingographies from 1,200 medical records of patients at the sterility and infertility out-patient clinic of the School of Medical Sciences of the State University of Campinas (Unicamp), from July, 1974 to December, 1981. The objective was to evaluate the incidence and main alterations diagnosed by hysterosalpingography. The most frequent findings were tuboperitoneal factors in 91% of the examinations, uterine cavity abnormalities in 17.4% and cervical factor in 6.3% of the cases. The examinations showed a great incident of tuboperitoneal abnormalities as cause of sterility from lower social classes. (author) [pt

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is taken ... and/or your insurance provider to get a better understanding of the possible charges you will incur. ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... sexually transmitted disease. Wear loose, comfortable clothing and leave jewelry at home. You may be asked to ... are sometimes the best way to see if treatment is working or if a finding is stable ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... sexually transmitted disease. Wear loose, comfortable clothing and leave jewelry at home. You may be asked to ... may also be asked to remove jewelry, removable dental appliances, eye glasses ... sometimes the best way to see if treatment is working or if a finding is stable ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... the area being examined by making it appear dark (or by electronically reversing the image contrast to ... x-ray examination. X-rays usually have no side effects in the typical diagnostic range for this ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... a chronic pelvic infection or an untreated sexually transmitted disease. Wear loose, comfortable clothing and leave jewelry at ... a chronic pelvic infection or an untreated sexually transmitted disease at the time of the procedure. On the ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... may also be asked to remove jewelry, removable dental appliances, eye glasses and any metal objects or ... and send a signed report to your primary care or referring physician , who will discuss the results ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... images for evaluation. National and international radiology protection organizations continually review and update the technique standards used ... ovaries, wall of the uterus, and other pelvic structures may be evaluated with MRI or ultrasound. Infertility ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician ... minimize radiation exposure to the baby. See the Safety page for more information about pregnancy and x- ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Imaging with ... Radiological Society of North America, Inc. (RSNA). To help ensure current and accurate information, we do not ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... ovaries, wall of the uterus, and other pelvic structures may be evaluated with MRI or ultrasound. Infertility ... information you were looking for? Yes No Please type your comment or suggestion into the following text ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed regularly by a physician with ... not responsible for the content contained on the web pages found at these links. About Us | Contact ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... minimize any potential discomfort. Some physicians prescribe an antibiotic prior to and/or after the procedure. You ... are sometimes the best way to see if treatment is working or if a finding is stable ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... stirrups and a speculum is inserted into the vagina. The cervix is then cleansed, and a catheter ... minimal and not long lasting. Most women experience vaginal spotting for a few days after the examination, ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Related Articles and ... Bleeding Cervical Cancer Endometrial Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... and/or your insurance provider to get a better understanding of the possible charges you will incur. ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... the body. X-rays are the oldest and most frequently used form of medical imaging. Fluoroscopy is ... light or radio waves. X-rays pass through most objects, including the body. Once it is carefully ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available ... may also be asked to remove jewelry, removable dental appliances, eye glasses and any metal objects or clothing that might interfere with the x-ray images. Women should always inform their physician and ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... at the time of the procedure. On the night before the procedure, you may be asked to ... an x-ray will be taken the next day to ensure that there is no scarring surrounding ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... laxative or an enema to empty your bowels, so that the uterus and surrounding structures can be ... Many imaging tests are not performed during pregnancy so as not to expose the fetus to radiation. ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... of the abdominal cavity, causing generalized lower abdominal pain, but this should also be minimal and not ... to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. The effective radiation dose ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... of the abdominal cavity, causing generalized lower abdominal pain, but this should also be minimal and not ... usually have no side effects in the typical diagnostic range for this exam. Risks There is always ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... an active inflammatory condition. Tell your physician or technologist if you have a chronic pelvic infection or ... inflammatory condition. You should notify your physician or technologist if you have a chronic pelvic infection or ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... any scarring within the uterine or peritoneal (abdominal) cavity . The procedure can be used to investigate repeated ... contrast material then begins to fill the uterine cavity , fallopian tubes and peritoneal cavity through the catheter ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... exposing a part of the body to a small dose of ionizing radiation to produce pictures of ... being examined, an x-ray machine produces a small burst of radiation that passes through the body, ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... are also captured and stored electronically on a computer. Until recently, x-ray images were maintained on ... images for evaluation. National and international radiology protection organizations continually review and update the technique standards used ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... completed within 30 minutes. top of page What will I experience during and after the procedure? This ... specifically trained to supervise and interpret radiology examinations, will analyze the images and send a signed report ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... Please note RadiologyInfo.org is not a medical facility. Please contact your physician with specific medical questions ... your community, you can search the ACR-accredited facilities database . This website does not provide cost information. ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, allergies and medications you’re taking. This ... material . An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... X-rays are a form of radiation like light or radio waves. X-rays pass through most objects, including the body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers top of page This page was reviewed on February 10, 2018 Send us your feedback Did you find the information you were ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... implant in the uterus. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic ... Send us your feedback Did you find the information you were looking for? Yes No Please type ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... her back on the exam table, with her knees bent or her feet held up with stirrups ... of the abdominal cavity, causing generalized lower abdominal pain, but this should also be minimal and not ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... uterus and fallopian tubes are filled with a water-soluble contrast material and the radiologist is able ... more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special ... About Us | Contact Us | FAQ | ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... of page Who interprets the results and how do I get them? A radiologist , a physician specifically ... E-mail: Area code: Phone no: Thank you! Do you have a personal story about radiology? Share ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit of an accurate ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available ... in X-Ray and CT Exams Contrast Materials Abnormal Vaginal Bleeding Cervical ... or for a referral to a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... ray technique that makes it possible to see internal organs in motion. During a hysterosalpingogram, the uterus ... possible for the physician to view joints or internal organs in motion. Still images or movies are ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... This website does not provide cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. Discuss the fees associated with your prescribed procedure with your doctor, ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... the uterus. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers top ... To locate a medical imaging or radiation oncology provider in your community, you can search the ACR- ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR and RSNA are not ... To help ensure current and accurate information, we do not permit copying but encourage linking ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... electronically reversing the image contrast to white), this special x-ray technique makes it possible for the physician to view joints or internal organs in motion. Still images or movies are also captured and stored electronically on a ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... through the body, recording an image on photographic film or a special detector. Fluoroscopy uses a continuous ... recently, x-ray images were maintained on large film sheets (much like a large photographic negative). Today, ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... you have any signs of pelvic infection or pelvic inflammatory disease. You will be asked to remove some of ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... areas. Outside links: For the convenience of our users, RadiologyInfo .org provides links to relevant ... To help ensure current and accurate information, we do not permit copying but encourage linking ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... The video is produced by the x-ray machine and a detector that is suspended over a ... of the body being examined, an x-ray machine produces a small burst of radiation that passes ...

  19. Hysterosalpingography

    Science.gov (United States)

    ... the area being examined by making it appear dark (or by electronically reversing the image contrast to ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... the area being examined by making it appear dark (or by electronically reversing the image contrast to ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... Share your patient story here Related Articles and Media Sonohysterography Uterine Fibroid Embolization (UFE) Radiation Dose in X-Ray and CT Exams Contrast Materials Abnormal Vaginal Bleeding Cervical Cancer Endometrial Cancer ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, treatments ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... in a known abnormality can be monitored over time. Follow-up examinations are sometimes the best way ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... or internal organs in motion. Still images or movies are also captured and stored electronically on a computer. Until recently, x-ray images were maintained on large film sheets (much like a large photographic negative). Today, ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... of Use | Links | Site Map Copyright © 2018 Radiological Society of North America, Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... remains in a patient's body after an x-ray examination. X-rays usually have no side effects in the ... Articles and Media Sonohysterography Uterine Fibroid Embolization (UFE) Radiation Dose in X-Ray and CT Exams Contrast Materials Abnormal Vaginal ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... minimize any potential discomfort. Some physicians prescribe an antibiotic prior to and/or after the procedure. You ... Radiological Society of North America, Inc. (RSNA). To help ensure current and accurate information, we do not ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available ... or suggestion into the following text box: Comment: E-mail: Area code: Phone no: Thank you! Do ... Recommend RadiologyInfo to a friend Send to (friend's e-mail address): From (your name): Your e-mail ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... pregnant. Many imaging tests are not performed during pregnancy so as not to expose the fetus to ... See the Safety page for more information about pregnancy and x-rays. top of page What does ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ... dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed regularly by a physician with expertise ... not responsible for the content contained on the web pages found at these links. About Us | Contact Us | ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... frequently compared to current x-ray images for diagnosis and disease management. top of page How is ... usually have no side effects in the typical diagnostic range for this exam. Risks There is always ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... a woman who is having difficulty becoming pregnant. It’s also used to investigate miscarriages resulting from abnormalities ... is a special x-ray technique that makes it possible to see internal organs in motion. During ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... usually have no side effects in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Fluoroscopy ... Share your patient story here Related Articles and Media ... Sponsored by Please note RadiologyInfo. ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... care is taken during x-ray examinations to use the lowest radiation dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site ... clothing that might interfere with the x-ray images. Women should always inform their physician and x- ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... pregnant by allowing the radiologist to evaluate the shape and structure of the uterus, the openness of ... exam table, with her knees bent or her feet held up with stirrups and a speculum is ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... When used with a contrast material, which clearly defines the area being examined by making it appear ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... after the procedure? This exam should cause only minor discomfort. There may be slight discomfort and cramping ... best images for evaluation. National and international radiology protection organizations continually review and update the technique standards ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... page was reviewed on February 10, 2018 Send us your feedback Did you find the information you were looking ... and Media Sonohysterography Uterine Fibroid Embolization (UFE) Radiation Dose in ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... one or two x-ray tubes and a television-like monitor that is located in the examining ... that are projected onto a fluorescent screen, or television-like monitor. When used with a contrast material, ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... you have any signs of pelvic infection or pelvic inflammatory disease. You will be asked to remove some of ... a large photographic negative). Today, most images are digital files that are stored electronically. These stored images ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... and send a signed report to your primary care or referring physician , who will discuss the results ... rays. A Word About Minimizing Radiation Exposure Special care is taken during x-ray examinations to use ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available ... reviewed on February 10, 2018 Send us your feedback Did you find the information you were looking ... procedures may vary by geographic region. Discuss the fees associated with your prescribed procedure with your doctor, ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... of a woman who is having difficulty becoming pregnant. It’s also used to investigate miscarriages resulting from ... fallopian tubes to allow the patient to become pregnant afterwards. Tell your doctor if there’s a possibility ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit ... and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers top of page This page was reviewed on ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... a large photographic negative). Today, most images are digital files that are stored electronically. These stored images ... ACR and RSNA are not responsible for the content contained on the web pages found at these ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... allowing the radiologist to evaluate the shape and structure of the uterus, the openness of the fallopian ... your bowels, so that the uterus and surrounding structures can be seen clearly. Prior to the procedure, ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... of the fallopian tubes, and to monitor the effects of tubal surgery, including: Blockage of the fallopian ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... your physician or technologist if you have a chronic pelvic infection or an untreated sexually transmitted disease. ... your physician or technologist if you have a chronic pelvic infection or an untreated sexually transmitted disease ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... It’s also used to investigate miscarriages resulting from abnormalities within the uterus and to determine the presence ... repeated miscarriages that result from congenital or acquired abnormalities of the uterus and to determine the presence ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... no: Thank you! Do you have a personal story about radiology? Share your patient story here Related ... Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 Radiological Society of North America, Inc. ( ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... radiation dose for this procedure varies. See the Safety page for more ... condition, pelvic infection or untreated sexually transmitted disease, be ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... minimize radiation exposure to the baby. See the Safety page for more information about pregnancy and x- ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... examination may also be necessary so that any change in a known abnormality can be monitored over ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ... message (optional): Bees: Wax: Notice: RadiologyInfo respects your privacy. Information entered here will not be used for ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... for more information about radiation dose. In the event of a chronic inflammatory condition, pelvic infection or ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... reviewed on February 10, 2018 Send us your feedback Did you find the information you were looking ... of North America, Inc. (RSNA). To help ensure current and accurate information, we do not permit copying ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... Radiology (ACR) and the Radiological Society of North America (RSNA), comprising physicians with expertise in several radiologic ... Site Map Copyright © 2018 Radiological Society of North America, Inc. (RSNA). To help ensure current and accurate ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... examine the uterus and fallopian tubes of a woman who is having difficulty becoming pregnant. It’s also ... uterosalpingography, is an x-ray examination of a woman's uterus and fallopian tubes that uses a special ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... fluoroscopy to view and assess their anatomy and function. top of page What are some common uses ... a form of radiation like light or radio waves. X-rays pass through most objects, including the ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... not responsible for the content contained on the web pages found at these links. About ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available ... more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is taken ... for the content contained on the web pages found at these links. About Us | Contact Us | FAQ | ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... uterus and fallopian tubes are filled with a water-soluble contrast material and the radiologist is able ... more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care ... About Us | Contact Us | FAQ | ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... are not responsible for the content contained on the web pages found at these links. ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... of the body to a small dose of ionizing radiation to produce pictures of the inside of ... a form of radiation like light or radio waves. X-rays pass through most objects, including the ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... clothing that might interfere with the x-ray images. Women should always inform their physician and x-ray ... lowest radiation dose possible while producing the best images for ... organizations continually review and update the technique standards used ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... the oldest and most frequently used form of medical imaging. Fluoroscopy is a special x-ray technique that ... a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... You should inform your physician of any medications being taken and if there are any allergies, especially ... carefully aimed at the part of the body being examined, an x-ray machine produces a small ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... conditions. Imaging with x-rays involves exposing a part of the body to a small dose of ... body. Once it is carefully aimed at the part of the body being examined, an x-ray ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ... minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... pregnant and discuss any recent illnesses, medical conditions, allergies and medications you’re taking. This procedure should ... medications being taken and if there are any allergies, especially to iodinated contrast materials . Also inform your ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... used to investigate repeated miscarriages that result from congenital or acquired abnormalities of the uterus and to ... of the fallopian tubes following a sterilization or disease-related blockage top of page How should I ...

  1. X-ray computed tomography for virtually unrolling damaged papyri

    Energy Technology Data Exchange (ETDEWEB)

    Allegra, Dario; Ciliberto, Paolo; Stanco, Filippo [Universita degli Studi di Catania, Dipartimento di Matematica ed Informatica, Catania (Italy); Ciliberto, Enrico [Universita degli Studi di Catania, Dipartimento di Scienze Chimiche, Catania (Italy); Petrillo, Giuseppe; Trombatore, Claudia [Universita degli Studi di Catania, Dipartimento di Scienze Mediche Chirurgiche e Tecnologie Avanzate, Catania (Italy)

    2016-03-15

    The regular format for ancient works of literature was the papyrus roll. Recently many efforts to perform virtual restoration of this archeological artifact have been done. In fact the case of ancient rolled papyrus is very intriguing. Old papyruses are the substrates of very important historical information, probably being the use of papyrus dated to the Pre-Dynastic Period. Papyrus degradation is often very hard so that physical unrolling is sometime absolutely impossible. In this paper, authors describe their effort in setting a new virtual restoration methodology based on software manipulation of X-ray tomographic images. A realistic model, obtained by painting a hieroglyph inscription of Thutmosis III on a papyrus substrate made by the original method described by Plinius the Elder and by pigments and binders compatible with the Egyptian use (ochers with natural glue), was made for the X-ray investigation. A GE Optima 660 64 slice was used to obtain a stack of tomographic slices of the rolled model. Each slice appears as spiral. The intensity variations along the cross-sectional result from ink on the papyrus. The files were elaborated with original software, written by the use of MATLAB high-level language, and the final result was quite similar to the radiography of the physically unrolled sheet. (orig.)

  2. X-ray computed tomography for virtually unrolling damaged papyri

    International Nuclear Information System (INIS)

    Allegra, Dario; Ciliberto, Paolo; Stanco, Filippo; Ciliberto, Enrico; Petrillo, Giuseppe; Trombatore, Claudia

    2016-01-01

    The regular format for ancient works of literature was the papyrus roll. Recently many efforts to perform virtual restoration of this archeological artifact have been done. In fact the case of ancient rolled papyrus is very intriguing. Old papyruses are the substrates of very important historical information, probably being the use of papyrus dated to the Pre-Dynastic Period. Papyrus degradation is often very hard so that physical unrolling is sometime absolutely impossible. In this paper, authors describe their effort in setting a new virtual restoration methodology based on software manipulation of X-ray tomographic images. A realistic model, obtained by painting a hieroglyph inscription of Thutmosis III on a papyrus substrate made by the original method described by Plinius the Elder and by pigments and binders compatible with the Egyptian use (ochers with natural glue), was made for the X-ray investigation. A GE Optima 660 64 slice was used to obtain a stack of tomographic slices of the rolled model. Each slice appears as spiral. The intensity variations along the cross-sectional result from ink on the papyrus. The files were elaborated with original software, written by the use of MATLAB high-level language, and the final result was quite similar to the radiography of the physically unrolled sheet. (orig.)

  3. X-ray computed tomography for virtually unrolling damaged papyri

    Science.gov (United States)

    Allegra, Dario; Ciliberto, Enrico; Ciliberto, Paolo; Petrillo, Giuseppe; Stanco, Filippo; Trombatore, Claudia

    2016-03-01

    The regular format for ancient works of literature was the papyrus roll. Recently many efforts to perform virtual restoration of this archeological artifact have been done. In fact the case of ancient rolled papyrus is very intriguing. Old papyruses are the substrates of very important historical information, probably being the use of papyrus dated to the Pre-Dynastic Period. Papyrus degradation is often very hard so that physical unrolling is sometime absolutely impossible. In this paper, authors describe their effort in setting a new virtual restoration methodology based on software manipulation of X-ray tomographic images. A realistic model, obtained by painting a hieroglyph inscription of Thutmosis III on a papyrus substrate made by the original method described by Plinius the Elder and by pigments and binders compatible with the Egyptian use (ochers with natural glue), was made for the X-ray investigation. A GE Optima 660 64 slice was used to obtain a stack of tomographic slices of the rolled model. Each slice appears as spiral. The intensity variations along the cross-sectional result from ink on the papyrus. The files were elaborated with original software, written by the use of MATLAB high-level language, and the final result was quite similar to the radiography of the physically unrolled sheet.

  4. Hysterosalpingography and laparoscopy in infertile women

    International Nuclear Information System (INIS)

    Konarzewska, J.; Bianek-Bodzak, A.; Mielcarek, P.; Kobierski, J.

    2009-01-01

    Background: Despite dynamic development of diagnostic imaging methods and endoscopic procedures, X-ray hysterosalpingography remains the basic diagnostic procedure when anatomical cause of infertility is suspected. The aim of the study was to assess the correlation between HSG results and laparoscopy findings, especially in infertile women with normal results of hysterosalpingography. Material/Methods: The results of HSG and laparoscopies performed between 2002 and 2005 years in 53 infertile women were analyzed retrospectively. The indication for HSG was primary infertility in 44 cases and secondary infertility in 9 cases.Results: The result of HSG was normal in 51%. Pathological findings were observed in 49% of HSG and in 93% of laparoscopies. The most common pathological findings observed during laparoscopy were tubal occlusion (26% cases) and endometriosis (25% cases). Polycystic ovaries and myomas were observed in 20% of the performed laparoscopies. HSG and laparoscopy yield consistent results in evaluation of tubal patency (p < 0.001). Conclusions: HSG remains the method of first choice in the diagnostics of uterine malformations and tubal diseases as causes of infertility. When mechanical factors of female infertility are suspected, HSG allows the optimal choice of more invasive procedure. (authors)

  5. The geometrical precision of virtual bone models derived from clinical computed tomography data for forensic anthropology.

    Science.gov (United States)

    Colman, Kerri L; Dobbe, Johannes G G; Stull, Kyra E; Ruijter, Jan M; Oostra, Roelof-Jan; van Rijn, Rick R; van der Merwe, Alie E; de Boer, Hans H; Streekstra, Geert J

    2017-07-01

    Almost all European countries lack contemporary skeletal collections for the development and validation of forensic anthropological methods. Furthermore, legal, ethical and practical considerations hinder the development of skeletal collections. A virtual skeletal database derived from clinical computed tomography (CT) scans provides a potential solution. However, clinical CT scans are typically generated with varying settings. This study investigates the effects of image segmentation and varying imaging conditions on the precision of virtual modelled pelves. An adult human cadaver was scanned using varying imaging conditions, such as scanner type and standard patient scanning protocol, slice thickness and exposure level. The pelvis was segmented from the various CT images resulting in virtually modelled pelves. The precision of the virtual modelling was determined per polygon mesh point. The fraction of mesh points resulting in point-to-point distance variations of 2 mm or less (95% confidence interval (CI)) was reported. Colour mapping was used to visualise modelling variability. At almost all (>97%) locations across the pelvis, the point-to-point distance variation is less than 2 mm (CI = 95%). In >91% of the locations, the point-to-point distance variation was less than 1 mm (CI = 95%). This indicates that the geometric variability of the virtual pelvis as a result of segmentation and imaging conditions rarely exceeds the generally accepted linear error of 2 mm. Colour mapping shows that areas with large variability are predominantly joint surfaces. Therefore, results indicate that segmented bone elements from patient-derived CT scans are a sufficiently precise source for creating a virtual skeletal database.

  6. Head and neck computed tomography virtual endoscopy: evaluation of a new imaging technique.

    Science.gov (United States)

    Gallivan, R P; Nguyen, T H; Armstrong, W B

    1999-10-01

    To evaluate a new radiographic imaging technique: computed tomography virtual endoscopy (CTVE) for head and neck tumors. Twenty-one patients presenting with head and neck masses who underwent axial computed tomography (CT) scan with contrast were evaluated by CTVE. Comparisons were made with video-recorded images and operative records to evaluate the potential utility of this new imaging technique. Twenty-one patients with aerodigestive head and neck tumors were evaluated by CTVE. One patient had a nasal cylindrical cell papilloma; the remainder, squamous cell carcinomas distributed throughout the upper aerodigestive tract. Patients underwent complete head and neck examination, flexible laryngoscopy, axial CT with contrast, CTVE, and in most cases, operative endoscopy. Available clinical and radiographic evaluations were compared and correlated to CTVE findings. CTVE accurately demonstrated abnormalities caused by intraluminal tumor, but where there was apposition of normal tissue against tumor, inaccurate depictions of surface contour occurred. Contour resolution was limited, and mucosal irregularity could not be defined. There was very good overall correlation between virtual images, flexible laryngoscopic findings, rigid endoscopy, and operative evaluation in cases where oncological resections were performed. CTVE appears to be most accurate in evaluation of subglottic and nasopharyngeal anatomy in our series of patients. CTVE is a new radiographic technique that provides surface-contour details. The technique is undergoing rapid technical evolution, and although the image quality is limited in situations where there is apposition of tissue folds, there are a number of potential applications for this new imaging technique.

  7. Structural findings at hysterosalpingography in patients with infertility ...

    African Journals Online (AJOL)

    Materials and Methods: A retrospective review of 289 consecutive patients who underwent hysterosalpingography using ionic water-soluble contrast media was done at 2 private x-ray units in Kampala. Clinical notes and radiological findings were analysed for demographic data, uterine status, tubal and pelvic pathology.

  8. Is hysterosalpingography still relevant in workup of infertility? A ...

    African Journals Online (AJOL)

    Objective: To examine the current role of Hysterosalpingography in the investigation of the infertile couple in view of the increasing use of Laparoscopy in the evaluation and management of infertility. Materials: Electronic search of published literature was done using the Pubmed, Cochrane libraries and Google search ...

  9. Hysterosalpingography (HSG) findings: Of infertile patients in Ilorin ...

    African Journals Online (AJOL)

    Purpose/Background: Infertility is a major gynecological complaint in Nigeria, constituting about fifty percent (50%) of gynecological clinic attendance1-3. Hysterosalpingography (HSG) is used as a first line investigative procedure for evaluating infertility cases. An analysis of HSG findings of patients with primary and ...

  10. Estimation of effective dose during hysterosalpingography procedures

    International Nuclear Information System (INIS)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M.; Sulieman, A.; Alsafi, K.; Omer, H.

    2014-08-01

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  11. Head to head comparison of optical coherence tomography, intravascular ultrasound echogenicity and virtual histology for the detection of changes in polymeric struts over time

    DEFF Research Database (Denmark)

    Brugaletta, Salvatore; Gomez-Lara, Josep; Bruining, Nico

    2012-01-01

    To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation. In the A......To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation...

  12. Application of computed tomography virtual noncontrast spectral imaging in evaluation of hepatic metastases: a preliminary study.

    Science.gov (United States)

    Tian, Shi-Feng; Liu, Ai-Lian; Liu, Jing-Hong; Sun, Mei-Yu; Wang, He-Qing; Liu, Yi-Jun

    2015-03-05

    The objective was to qualitatively and quantitatively evaluate hepatic metastases using computed tomography (CT) virtual noncontrast (VNC) spectral imaging in a retrospective analysis. Forty hepatic metastases patients underwent CT scans including the conventional true noncontrast (TNC) and the tri-phasic contrast-enhanced dual energy spectral scans in the hepatic arterial, portal venous, and equilibrium phases. The tri-phasic spectral CT images were used to obtain three groups of VNC images including in the arterial (VNCa), venous (VNCv), and equilibrium (VNCe) phase by the material decomposition process using water and iodine as a base material pair. The image quality and the contrast-to-noise ratio (CNR) of metastasis of the four groups were compared with ANOVA analysis. The metastasis detection rates with the four nonenhanced image groups were calculated and compared using the Chi-square test. There were no significant differences in image quality among TNC, VNCa and VNCv images (P > 0.05). The quality of VNCe images was significantly worse than that of other three groups (P 0.05). The metastasis detection rate of the four nonenhanced groups with no statistically significant difference (P > 0.05). The quality of VNCa and VNCv images is identical to that of TNC images, and the metastasis detection rate in VNC images is similar to that in TNC images. VNC images obtained from arterial phase show metastases more clearly. Thus, VNCa imaging may be a surrogate to TNC imaging in hepatic metastasis diagnosis.

  13. Application of Computed Tomography Virtual Noncontrast Spectral Imaging in Evaluation of Hepatic Metastases: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Shi-Feng Tian

    2015-01-01

    Full Text Available Objective: The objective was to qualitatively and quantitatively evaluate hepatic metastases using computed tomography (CT virtual noncontrast (VNC spectral imaging in a retrospective analysis. Methods: Forty hepatic metastases patients underwent CT scans including the conventional true noncontrast (TNC and the tri-phasic contrast-enhanced dual energy spectral scans in the hepatic arterial, portal venous, and equilibrium phases. The tri-phasic spectral CT images were used to obtain three groups of VNC images including in the arterial (VNCa, venous (VNCv, and equilibrium (VNCe phase by the material decomposition process using water and iodine as a base material pair. The image quality and the contrast-to-noise ratio (CNR of metastasis of the four groups were compared with ANOVA analysis. The metastasis detection rates with the four nonenhanced image groups were calculated and compared using the Chi-square test. Results: There were no significant differences in image quality among TNC, VNCa and VNCv images (P > 0.05. The quality of VNCe images was significantly worse than that of other three groups (P 0.05. The metastasis detection rate of the four nonenhanced groups with no statistically significant difference (P > 0.05. Conclusions: The quality of VNCa and VNCv images is identical to that of TNC images, and the metastasis detection rate in VNC images is similar to that in TNC images. VNC images obtained from arterial phase show metastases more clearly. Thus, VNCa imaging may be a surrogate to TNC imaging in hepatic metastasis diagnosis.

  14. Material decomposition and virtual non-contrast imaging in photon counting computed tomography: an animal study

    Science.gov (United States)

    Gutjahr, R.; Polster, C.; Kappler, S.; Pietsch, H.; Jost, G.; Hahn, K.; Schöck, F.; Sedlmair, M.; Allmendinger, T.; Schmidt, B.; Krauss, B.; Flohr, T. G.

    2016-03-01

    The energy resolving capabilities of Photon Counting Detectors (PCD) in Computed Tomography (CT) facilitate energy-sensitive measurements. The provided image-information can be processed with Dual Energy and Multi Energy algorithms. A research PCD-CT firstly allows acquiring images with a close to clinical configuration of both the X-ray tube and the CT-detector. In this study, two algorithms (Material Decomposition and Virtual Non-Contrast-imaging (VNC)) are applied on a data set acquired from an anesthetized rabbit scanned using the PCD-CT system. Two contrast agents (CA) are applied: A gadolinium (Gd) based CA used to enhance contrasts for vascular imaging, and xenon (Xe) and air as a CA used to evaluate local ventilation of the animal's lung. Four different images are generated: a) A VNC image, suppressing any traces of the injected Gd imitating a native scan, b) a VNC image with a Gd-image as an overlay, where contrast enhancements in the vascular system are highlighted using colored labels, c) another VNC image with a Xe-image as an overlay, and d) a 3D rendered image of the animal's lung, filled with Xe, indicating local ventilation characteristics. All images are generated from two images based on energy bin information. It is shown that a modified version of a commercially available dual energy software framework is capable of providing images with diagnostic value obtained from the research PCD-CT system.

  15. Characterizing root system characteristics with Electrical resistivity Tomography: a virtual rhizotron simulation

    Science.gov (United States)

    Rao, Sathyanarayan; Ehosioke, Solomon; Lesparre, Nolwenn; Nguyen, Frédéric; Javaux, Mathieu

    2017-04-01

    Electrical Resistivity Tomography (ERT) is more and more used for monitoring soil water content in a cropped soil. Yet, the impact of roots on the signal is often neglected and a topic of controversy. In several studies related to soil-root system, it has been showed that the measured root mass density statistically correlates with the electrical conductivity (EC) data obtained from ERT. In addition, some studies suggest that some roots are more electrically conductive than soil for most water content. Thus, higher EC of roots suggest that it might have a measurable impact on ERT signals. In this work, virtual rhizotrons are simulated using the software package called R-SWMS that solves water and solute transport in plant root-soil system, including root growth. The distribution of water content obtained from R-SWMS simulation is converted into EC data using pedo-physical models. The electrical properties of roots and rhizosphere are explicitly included in the EC data to form a conductivity map (CM) with a very detailed spatial resolution. Forward ERT simulations is then carried out for CM generated for various root architectures and soil conditions to study the impact of roots on ERT forward (current and voltage patterns) and inverse solutions. It is demonstrated that under typical injection schemes with lateral electrodes, root system is hardly measurable. However, it is showed that adding electrodes and constraints on the ERT inversion based on root architecture help quantifying root system mass and extent.

  16. The use of cone-beam computed tomography and virtual reality simulation for pre-surgical practice in endodontic microsurgery.

    Science.gov (United States)

    Suebnukarn, S; Rhienmora, P; Haddawy, P

    2012-07-01

    To design and evaluate the impact of virtual reality (VR) pre-surgical practice on the performance of actual endodontic microsurgery.   The VR system operates on a laptop with a 1.6-GHz Intel processor and 2 GB of main memory. Volumetric cone-beam computed tomography (CBCT) data were acquired from a fresh cadaveric porcine mandible prior to endodontic microsurgery. Ten inexperienced endodontic trainees were randomized as to whether they performed endodontic microsurgery with or without virtual pre-surgical practice. The VR simulator has microinstruments to perform surgical procedures under magnification. After the initial endodontic microsurgery, all participants served as their own controls by performing another procedure with or without virtual pre-surgical practice. All procedures were videotaped and assessed by two independent observers using an endodontic competency rating scale (from 6 to 30). A significant difference was observed between the scores for endodontic microsurgery on molar teeth completed with virtual pre-surgical practice and those completed without virtual presurgical practice, median 24.5 (range = 17-28) versus median 18.75 (range = 14-26.5), P = 0.041. A significant difference was observed between the scores for osteotomy on a molar tooth completed with virtual pre-surgical practice and those completed without virtual pre-surgical practice, median 4.5 (range = 3.5-4.5) versus median 3 (range = 2-4), P = 0.042. Pre-surgical practice in a virtual environment using the 3D computerized model generated from the original CBCT image data improved endodontic microsurgery performance. © 2012 International Endodontic Journal.

  17. Aortic endograft surveillance: use of fast-switch kVp dual-energy computed tomography with virtual noncontrast imaging.

    Science.gov (United States)

    Maturen, Katherine E; Kleaveland, Patricia A; Kaza, Ravi K; Liu, Peter S; Quint, Leslie E; Khalatbari, Shokoufeh H; Platt, Joel F

    2011-01-01

    To assess endoleak detection and patients' radiation exposure using fast-switch peak kilovoltage (kVp) dual-energy computed tomography (DECT) with virtual noncontrast (VNC) imaging. Institutional review board approved retrospective review of triphasic CTs for endograft follow-up: single-energy true noncontrast (TNC) and dual-energy arterial- and venous-phase postcontrast scans on GE HD-750 64-detector scanners. Iodine-subtracted VNC images generated from dual-energy data. Two radiologists (VNC readers) independently performed 2 reading sessions without TNC images: (1) arterial and VNC and (2) venous and VNC. Interrater agreement, leak detection sensitivity, and dose estimates were calculated. Original dictations described 24 endoleaks in 78 scans. Virtual noncontrast reader agreement was high (κ = 0.78-0.79). Virtual noncontrast reader ranges for sensitivity and negative predictive value for leak detection were 87.5% to 95.8% and 94.0% to 98.0% in venous phase. Dose reduction estimate was 40% by eliminating one phase and 64% by eliminating 2 phases of imaging. Virtual noncontrast images from fast-switch peak kilovoltage DECT data can substitute for TNC imaging in the postendograft aorta, conferring substantial dose reduction. Eliminating 1 of 2 postcontrast phases further reduces dose, with greater negative predictive value for leak detection in the venous versus the arterial phase. Thus, the use of a monophasic venous-phase DECT with VNC images is suggested for long-term endograft surveillance in stable patients.

  18. Image Guided Virtual Autopsy: An Adjunct with Radiographic and Computed Tomography Modalities - An Important Tool in Forensic Identification

    Directory of Open Access Journals (Sweden)

    Shalu Rai

    2017-01-01

    Full Text Available The forensic examination of dead bodies is very helpful in order to identify the person, cause of death, gender, and solving the mysterious cases. It includes a number of techniques, out of which autopsy is the primary investigation that is performed in every medicolegal case. Because of mutilation technologies, traditional autopsy technique is most disturbing in terms of emotions and rituals of relatives. The use of radiology in forensic science comprises performance, interpretation, and reporting of radiographs that is helpful in detecting those changes that are not clinically visible. Forensic radiology plays an important role for identification of humans in mass disasters, criminal investigations, and evaluation of cause of death. The introduction of radiological modalities in autopsy techniques is a complementary tool for forensic identification and is known as virtual autopsy. The advance imaging techniques such as computed tomography (CT and magnetic resonance imaging (MRI is used in virtual autopsy in order to visualize and reconstruct the internal organs to know the site, type, and depth of injury. This review elaborates the role of maxillofacial imaging in image-guided virtual autopsy.

  19. The geometrical precision of virtual bone models derived from clinical computed tomography data for forensic anthropology

    NARCIS (Netherlands)

    Colman, Kerri L.; Dobbe, Johannes G. G.; Stull, Kyra E.; Ruijter, Jan M.; Oostra, Roelof-Jan; van Rijn, Rick R.; van der Merwe, Alie E.; de Boer, Hans H.; Streekstra, Geert J.

    2017-01-01

    Almost all European countries lack contemporary skeletal collections for the development and validation of forensic anthropological methods. Furthermore, legal, ethical and practical considerations hinder the development of skeletal collections. A virtual skeletal database derived from clinical

  20. Generation of realistic virtual nodules based on three-dimensional spatial resolution in lung computed tomography: A pilot phantom study.

    Science.gov (United States)

    Narita, Akihiro; Ohkubo, Masaki; Murao, Kohei; Matsumoto, Toru; Wada, Shinichi

    2017-10-01

    The aim of this feasibility study using phantoms was to propose a novel method for obtaining computer-generated realistic virtual nodules in lung computed tomography (CT). In the proposed methodology, pulmonary nodule images obtained with a CT scanner are deconvolved with the point spread function (PSF) in the scan plane and slice sensitivity profile (SSP) measured for the scanner; the resultant images are referred to as nodule-like object functions. Next, by convolving the nodule-like object function with the PSF and SSP of another (target) scanner, the virtual nodule can be generated so that it has the characteristics of the spatial resolution of the target scanner. To validate the methodology, the authors applied physical nodules of 5-, 7- and 10-mm-diameter (uniform spheres) included in a commercial CT test phantom. The nodule-like object functions were calculated from the sphere images obtained with two scanners (Scanner A and Scanner B); these functions were referred to as nodule-like object functions A and B, respectively. From these, virtual nodules were generated based on the spatial resolution of another scanner (Scanner C). By investigating the agreement of the virtual nodules generated from the nodule-like object functions A and B, the equivalence of the nodule-like object functions obtained from different scanners could be assessed. In addition, these virtual nodules were compared with the real (true) sphere images obtained with Scanner C. As a practical validation, five types of laboratory-made physical nodules with various complicated shapes and heterogeneous densities, similar to real lesions, were used. The nodule-like object functions were calculated from the images of these laboratory-made nodules obtained with Scanner A. From them, virtual nodules were generated based on the spatial resolution of Scanner C and compared with the real images of laboratory-made nodules obtained with Scanner C. Good agreement of the virtual nodules generated from

  1. Therapeutic value of hysterosalpingography with Lipiodol ultra fluid

    International Nuclear Information System (INIS)

    Rasmussen, F.; Justesen, P.; Toenner Nielsen, D.

    1987-01-01

    Hysterosalpingography (HSG) with Lipiodol ultra fluid was performed in 294 infertile women with a normal ovulatory temperature curve and at least two years of infertility and a partner with normal sperm. In 21%, pregnancy occurred within 6 months after the examination, and about one third of the women with a normal finding or with intraperitoneal adhesions at HSG conceived. The pregnancy rate was especially high in the first two cycles after HSG. The spontaneous pregnancy rate was 8%, and the difference between this and the total number of pregnancies must be attributed to a therapeutic effect of the procedure. Previous pelvic inflammatory disease was present in 40% of those who did not become pregnant, while only 11% of those who conceived had previous inflammation. Of the women without previous gynecologic disease 30% conceived. (orig.)

  2. Evaluation of occupational radiation dose of extremities on hysterosalpingography

    International Nuclear Information System (INIS)

    Filipov, D.; Kotowski, S.T.A.

    2017-01-01

    In the Hysterosalpingography (HSG) exam there is always a professional present with their hands very close to the radiation field. Based on CNEN, individuals occupationally exposed to radiation have equivalent dose limit values for the extremities (500 mSv / year). The objective of the study was to verify the equivalent dose in the hand region of an IOE (Occupationally Exposed Individual) that performs the HSG test and to compare it with the CNEN limit and with similar studies. A humanoid phantom was used to simulate the patient and an ionization chamber, which was placed in the place commonly occupied by the professional. The equivalent hand dose result (∼ 30 mSv / year) equals 6% of the CNEN annual dose limit, but is close to most studies using fluoroscopes. Therefore, the optimization of radiological protection is necessary to reduce these results

  3. A cone-beam computed tomography triple scan procedure to obtain a three-dimensional augmented virtual skull model appropriate for orthognathic surgery planning.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mollemans, W.; Clercq, C. De; Abeloos, J.V.S.; Lamoral, P.; Lippens, F.R.C.; Neyt, N.; Casselman, J.W.; Schutyser, F.A.C.

    2009-01-01

    The aim of this study was to present a new approach to acquire a three-dimensional virtual skull model appropriate for orthognathic surgery planning without the use of plaster dental models and without deformation of the facial soft-tissue mask. A "triple" cone-beam computed tomography (CBCT) scan

  4. The use of a wax bite wafer and a double computed tomography scan procedure to obtain a three-dimensional augmented virtual skull model.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mommaerts, M.Y.; Abeloos, J.V.S.; Clercq, C. De; Lamoral, P.; Neyt, N.; Casselman, J.W.; Schutyser, F.A.C.

    2007-01-01

    A detailed visualization of the interocclusal relationship is essential in a three-dimensional virtual planning setup for orthognathic and facial orthomorphic surgery. The purpose of this study was to introduce and evaluate the use of a wax bite wafer in combination with a double computed tomography

  5. Tomography

    International Nuclear Information System (INIS)

    1985-01-01

    Already widely accepted in medicine, tomography can also be useful in industry. The theory behind tomography and a demonstration of the technique to inspect a motorcycle carburetor is presented. To demonstrate the potential of computer assisted tomography (CAT) to accurately locate defects in three dimensions, a sectioned 5 cm gate valve with a shrink cavity made visible by the sectioning was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +-1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  6. Virtual computed tomography colonoscopy: artifacts, image quality and radiation dose load in a cadaver study

    International Nuclear Information System (INIS)

    Springer, P.; Stoehr, B.; Giacomuzzi, S.M.; Bodner, G.; Jaschke, W.; Nedden, D. zur; Klingler, A.

    2000-01-01

    The purpose of our study was to evaluate the interdependency of spatial resolution, image reconstruction artifacts, and radiation doses in virtual CT colonoscopy by comparing various CT scanning protocols. A pig's colon with several artificial polypoid lesions was imaged after air insufflation with helical CT scanning using 1-, 3-, and 5-mm collimation, and pitch values varying from 1.0 to 3.0. Virtual endoscopic images and ''fly through'' sequences were calculated on a Sun Sparc 20 workstation (Navigator Software, GE Medical Systems, Milwaukee, Wis.). Several reconstruction artifacts as well as overall image quality were evaluated by three independent reviewers. In addition, radiation doses for the different CT protocols were measured as multiple-scan average dose using a 10-cm ion chamber and a standard Plexiglass body phantom. Generally, image quality and reconstruction artifacts were less affected by pitch values than by beam collimation. Thus, narrow beam collimation at higher pitch values (e. g. 3 mm/2.0) seems to be a reasonable compromise between quality of virtual endoscopic images and radiation dose load. (orig.)

  7. Tomography

    International Nuclear Information System (INIS)

    Barrett, H.H.; Gordon, S.; Swindell, W.

    1980-01-01

    Apparatus is described for generating a two-dimensional back-projected image of a slice of an object in tomography. The apparatus uses optical techniques to perform the functions of filtering and back projection. Central to the technique is a cylindrical drum which rotates at a fast rate and whose rotational axis tilts at a slower rate. The novel method overcomes the problem of image blurring due to motion which occurs in many tomographic techniques. It also has the advantages of being less expensive and simpler compared to tomography using digital processing techniques which require fast computers. (UK)

  8. A computer-simulated liver phantom (virtual liver phantom) for multidetector computed tomography evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Funama, Yoshinori [Kumamoto University, Department of Radiological Sciences, School of Health Sciences, Kumamoto (Japan); Awai, Kazuo; Nakayama, Yoshiharu; Liu, Da; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto (Japan); Miyazaki, Osamu; Goto, Taiga [Hitachi Medical Corporation, Tokyo (Japan); Hori, Shinichi [Gate Tower Institute of Image Guided Therapy, Osaka (Japan)

    2006-04-15

    The purpose of study was to develop a computer-simulated liver phantom for hepatic CT studies. A computer-simulated liver phantom was mathematically constructed on a computer workstation. The computer-simulated phantom was calibrated using real CT images acquired by an actual four-detector CT. We added an inhomogeneous texture to the simulated liver by referring to CT images of chronically damaged human livers. The mean CT number of the simulated liver was 60 HU and we added numerous 5-to 10-mm structures with 60{+-}10 HU/mm. To mimic liver tumors we added nodules measuring 8, 10, and 12 mm in diameter with CT numbers of 60{+-}10, 60{+-}15, and 60{+-}20 HU. Five radiologists visually evaluated similarity of the texture of the computer-simulated liver phantom and a real human liver to confirm the appropriateness of the virtual liver images using a five-point scale. The total score was 44 in two radiologists, and 42, 41, and 39 in one radiologist each. They evaluated that the textures of virtual liver were comparable to those of human liver. Our computer-simulated liver phantom is a promising tool for the evaluation of the image quality and diagnostic performance of hepatic CT imaging. (orig.)

  9. Usefulness of computed tomography virtual bronchoscopy in the evaluation of bronchi divisions

    International Nuclear Information System (INIS)

    Adamczyk, Michał; Tomaszewski, Grzegorz; Naumczyk, Patrycja; Kluczewska, Ewa; Walecki, Jerzy

    2013-01-01

    Since introduction of multislice CT scanners into clinical practice, virtual brochoscopy has gained a lot of quality and diagnostic potential. Nevertheless it does not have established place in diagnostics of tracheal and bronchi disorders and its potential has not been examined enough. Nowadays a majority of bronchial tree variants and lesions are revealed by bronchofiberoscopy, which is an objective and a relatively safe method, but has side effects, especially in higher-risk subjects. Therefore noninvasive techniques enabling evaluation of airways should be consistently developed and updated. Material consisted of 100 adults (45 female, 55 male) aged between 18 and 65 years (mean 40 years, median 40.5 years, SD 14.02), who underwent chest CT examination by means of a 16-slice scanner. Every patient had normal appearance of chest organs, with the exception of minor abnormalities that did not alter airways route. Divisions of bronchial tree to segmental level were evaluated and assigned to particular types by means of virtual bronchoscopy projection. In case of difficulties MPR or MinIP projection was used. The frequency of lobar bronchi divisions other than the typical ones was in: right upper lobar bronchi 45%, left 55%; middle lobar bronchi 21%, lingula 26%; right lower lobar bronchi 28%, left 29%. Subsuperior bronchus or bronchi were found on the right side in 44% and on the left side in 37%. No dependency between types of bronchial divisions on different levels was found

  10. Post-Essure hysterosalpingography compliance in a clinic population.

    Science.gov (United States)

    Shavell, Valerie I; Abdallah, Mazen E; Diamond, Michael P; Kmak, David C; Berman, Jay M

    2008-01-01

    To determine the follow-up rate for post-Essure hysterosalpingography (HSG) in a non-study, general clinic population in an urban environment. Retrospective chart review (Canadian Task Force classification II-2). University teaching hospital. Eighty-three University Health Center (UHC) patients who underwent attempted placement of the Essure permanent birth control device at the ambulatory surgery center at Hutzel Women's Hospital from January 2003 through June 2007. Hysteroscopic placement of the Essure permanent birth control device. Placement of the Essure permanent birth control device was attempted in 83 patients, of which 79 were successfully completed (95.2%). Of the 79 patients, 10 underwent post-Essure HSG (12.7%). HSG was performed 3 to 6 months after placement of the Essure device. Bilateral tubal occlusion was documented in all 10 patients. Despite preoperative and postoperative counseling, the follow-up rate for post-Essure HSG for this clinic population was only 12.7%. For those in whom HSG was performed, bilateral tubal occlusion was confirmed in all. Steps or approaches to promote compliance with postprocedural confirmation of tubal occlusion should be utilized to improve future follow-up rates.

  11. Tomography

    International Nuclear Information System (INIS)

    Allan, C.J.; Keller, N.A.; Lupton, L.R.; Taylor, T.; Tonner, P.D.

    1984-10-01

    Tomography is a non-intrusive imaging technique being developed at CRNL as an industrial tool for generating quantitative cross-sectional density maps of objects. Of most interest is tomography's ability to: distinguish features within complex geometries where other NDT techniques fail because of the complexity of the geometry; detect/locate small density changes/defects within objects, e.g. void fraction measurements within thick-walled vessels, shrink cavities in castings, etc.; provide quantitative data that can be used in analyses, e.g. of complex processes, or fracture mechanics; and provide objective quantitative data that can be used for (computer-based) quality assurance decisions, thereby reducing and in some cases eliminating the present subjectivity often encountered in NDT. The CRNL program is reviewed and examples are presented to illustrate the potential and the limitations of the technology

  12. Translation of First North American 50 and 70 cc Total Artificial Heart Virtual and Clinical Implantations: Utility of 3D Computed Tomography to Test Fit Devices.

    Science.gov (United States)

    Ferng, Alice S; Oliva, Isabel; Jokerst, Clinton; Avery, Ryan; Connell, Alana M; Tran, Phat L; Smith, Richard G; Khalpey, Zain

    2017-08-01

    Since the creation of SynCardia's 50 cc Total Artificial Hearts (TAHs), patients with irreversible biventricular failure now have two sizing options. Herein, a case series of three patients who have undergone successful 50 and 70 cc TAH implantation with complete closure of the chest cavity utilizing preoperative "virtual implantation" of different sized devices for surgical planning are presented. Computed tomography (CT) images were used for preoperative planning prior to TAH implantation. Three-dimensional (3D) reconstructions of preoperative chest CT images were generated and both 50 and 70 cc TAHs were virtually implanted into patients' thoracic cavities. During the simulation, the TAHs were projected over the native hearts in a similar position to the actual implantation, and the relationship between the devices and the atria, ventricles, chest wall, and diaphragm were assessed. The 3D reconstructed images and virtual modeling were used to simulate and determine for each patient if the 50 or 70 cc TAH would have a higher likelihood of successful implantation without complications. Subsequently, all three patients received clinical implants of the properly sized TAH based on virtual modeling, and their chest cavities were fully closed. This virtual implantation increases our confidence that the selected TAH will better fit within the thoracic cavity allowing for improved surgical outcome. Clinical implantation of the TAHs showed that our virtual modeling was an effective method for determining the correct fit and sizing of 50 and 70 cc TAHs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  13. Uterine and tubal anatomical abnormalities in infertile women: diagnosis with routine hysterosalpingography prior to selective laparoscopy

    Directory of Open Access Journals (Sweden)

    Mwaffaq Heis

    2011-12-01

    Full Text Available Objective: To assess the findings and usefulness of hysterosalpingography as a routine investigation in the fertility workup prior to selective laparoscopy. Design: Descriptive retrospective study. Setting: A university hospital in the north of Jordan. Subjects: All hysterosalpingographies performed in the period between 1st January and 31 December 2008. Outcome measures: Detection of uterine and fallopian tube abnormalities and their correlation with laparoscopic findings. Results: During the study period, 281 infertile women underwent hysterosalpingography with no post procedural complications. The mean (SD age was 31.5 (5.91 years. Mean (SD duration of infertility was 4 (3.44 years. Infertility was reported as primary and secondary by 119 (42.3 % and 162 (57.6 %, respectively. Altogether 281 patients and 562 tubes were examined. Of those, 402 were patent and 160 occluded. There was only one woman in whom peritubal adhesions were diagnosed. Because of hysterosalpingographically diagnosed tubal occlusion, 46 women (16.4 % were referred for laparoscopy. Eight (17.3% of them were treated with unilateral salpingectomy and 28 (60.8% with bilateral salpingectomy. Salpingolysis was performed for 7 (15.2% women, and 3 (6.7% women had untreatable adhesions. The concordance was 71.7%. The sensitivity of HSG was 80%, the specificity 50%, the negative predictive value 61% and the positive predictive value 71%. Of the total of 281 women, 30 (10.7% conceived within 1 - 11 months after the hysterosalpingography. Conclusions: The very high abnormal predictive value of hysterosalpingography in the diagnosis of tubal occlusion suggests that this procedure could be performed as a screening examination.

  14. Dual energy virtual CT colonoscopy with dual source computed tomography. Initial experience

    International Nuclear Information System (INIS)

    Karcaaltincaba, M.; Karaosmanoglu, D.; Akata, D.; Sentuerk, S.; Oezmen, M.; Alibek, S.

    2009-01-01

    Purpose: To describe the technique of DE MDCT colonoscopy and to assess its feasibility. Materials and Methods: 8 patients were scanned with DSCT with a DE scan protocol and dose modulation software. Analysis was performed using dedicated DE software. Prone non-contrast images and DE supine images after contrast injection were obtained. Results: DE colonoscopic images were successfully obtained in 7 patients, but the FOV did not cover all colonic segments in 1 patient, thus resulting in a technical success rate was 87.5%. Streak artifacts were present in the pelvic region in 2 patients. Virtual unenhanced images and iodine map images were obtained for all patients. In 1 patient a polypoid non-enhancing structure was noted on the iodine map, and conventional colonoscopy revealed impacted stool. Enhancing rectal cancer in 1 patient was correctly shown on the iodine map. Iodine maps helped to differentiate stool fragments/retained fluid by the absence of enhancement when compared to prone CT images. The major advantage of DE colonoscopy was the lack of misregistration. Conclusion: DE MDCT colonoscopy is technically feasible and may obviate the need for unenhanced prone images. It may be possible to perform noncathartic DECT colonoscopy. The major limitation is the limited FOV of tube B. The dose should be optimized to reduce streak artifacts in the pelvic region. (orig.)

  15. [Virtual endoscopic navigation and body transparency based on computed tomography. A step towards in vivo imaging].

    Science.gov (United States)

    Cabanis, Emmanuel-Alain; Gombergh, Rodolphe; Castro, Albert; Gandjbakhch, Iradj; Iba-Zizen, Marie-Thérèse; Dubois, François

    2011-06-01

    Progress in HR-CTdata processing has led to lower X-ray exposure and to better diagnostic performance. We describe 19 adult patients (among 5000) examined by HR CT with 64 detectors, acquisition and exposure protocols in mSv, spiral, 0.6-mm slices, 5To PACS. After the two usual processing steps (60 gray values, 5122 and 10242 matrices, dedicated workstations for coronaroscopy and virtual coloscopy, 2D multiplanar reformation, surfacic, 3D volumes with dissection and navigation), a third original data processing step on additional workstations was added. Variable matrix extrapolated images, flexible colored curves (different from anatomical conventions), lighting (sources) and transparencies (unavailable with traditional endoscopy) were used. The digital film is a 16-minute "journey "consisting of 19 endo-body navigations in 5 regions, from the head to the bronchi, from the heart to the coronary arteries, and from the digestive tract to the abdomen and pelvis. One possible application is post-operative verification of an aortic graft. The movie is illustrated here with ten plates. This new approach is cost-effective and beneficial for the patient, in terms of early diagnosis and therapeutic follow-up. Ethical issues are also examined.

  16. Use of the stereoscopic virtual reality display system for the detection and characterization of intracranial aneurysms: A Icomparison with conventional computed tomography workstation and 3D rotational angiography.

    Science.gov (United States)

    Liu, Xiujuan; Tao, Haiquan; Xiao, Xigang; Guo, Binbin; Xu, Shangcai; Sun, Na; Li, Maotong; Xie, Li; Wu, Changjun

    2018-07-01

    This study aimed to compare the diagnostic performance of the stereoscopic virtual reality display system with the conventional computed tomography (CT) workstation and three-dimensional rotational angiography (3DRA) for intracranial aneurysm detection and characterization, with a focus on small aneurysms and those near the bone. First, 42 patients with suspected intracranial aneurysms underwent both 256-row CT angiography (CTA) and 3DRA. Volume rendering (VR) images were captured using the conventional CT workstation. Next, VR images were transferred to the stereoscopic virtual reality display system. Two radiologists independently assessed the results that were obtained using the conventional CT workstation and stereoscopic virtual reality display system. The 3DRA results were considered as the ultimate reference standard. Based on 3DRA images, 38 aneurysms were confirmed in 42 patients. Two cases were misdiagnosed and 1 was missed when the traditional CT workstation was used. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the conventional CT workstation were 94.7%, 85.7%, 97.3%, 75%, and99.3%, respectively, on a per-aneurysm basis. The stereoscopic virtual reality display system missed a case. The sensitivity, specificity, PPV, NPV, and accuracy of the stereoscopic virtual reality display system were 100%, 85.7%, 97.4%, 100%, and 97.8%, respectively. No difference was observed in the accuracy of the traditional CT workstation, stereoscopic virtual reality display system, and 3DRA in detecting aneurysms. The stereoscopic virtual reality display system has some advantages in detecting small aneurysms and those near the bone. The virtual reality stereoscopic vision obtained through the system was found as a useful tool in intracranial aneurysm diagnosis and pre-operative 3D imaging. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography

    International Nuclear Information System (INIS)

    Lopes, Cintya Carolina Barbosa

    2006-04-01

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  18. Difficulties in recruitment for a randomized controlled trial involving hysterosalpingography

    Directory of Open Access Journals (Sweden)

    Helmerhorst Frans M

    2006-06-01

    Full Text Available Abstract Background The usefulness of hysterosalpingography (HSG as routine investigation in the fertility work-up prior to laparoscopy and dye had been assessed in a randomized controlled trial. Recruiting subjects to the study was more difficult than anticipated. The objective of this study was to explore possible reasons for non-participation in the trial. Methods All newly referred subfertile women admitted to the Reproductive Medicine Clinic of Leiden University Medical Centre between 1 April 1997 and 31 December 1999, were eligible for the study. The reasons for non-participation were evaluated by scrutinizing the medical records. Results Out of 759 women, a total of 127 (17% agreed to participate in the trial. The most important reason for non-participation was because of exclusion criteria (73%. Other reasons were inattentive clinicians (3% and patient-associated reasons (24%. Patient refusal and indecisiveness to enroll in the study were the most common patient-associated reasons. The most frequently stated reason for trial refusal was reluctance to undergo laparoscopy and dye mainly due to issues related to anesthesia and scheduling of procedure. Conclusion Almost three-quarters of recruitment difficulties in this study were due to unavoidable reasons. To overcome the remaining avoidable reasons for non-participation, attention should be paid to appropriate instruction of the study protocol to the participating doctors and to provide adequate information, in layman's terms, to the patients. Reminding patients by notes or telephone calls for attending the clinic are helpful. It may be contingent upon tracing the reasons of clinicians and patients for non-participation to improve enrollment during a trial.

  19. Estimation of effective dose during hysterosalpingography procedures; Estimación de dosis efectiva durante los procedimientos hysterosalpingography

    Energy Technology Data Exchange (ETDEWEB)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M. [King Saud University, College of Applied Medical Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433, (Saudi Arabia); Sulieman, A. [Salman bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P. O. Box 422, Alkharj (Saudi Arabia); Alsafi, K. [King Abdulaziz University, Faculty of Medicine, Radiology Department, Jeddah 22254 (Saudi Arabia); Omer, H., E-mail: kalzimami@ksu.edu.sa [Dammam University, Faculty of Medicine, Dammam Khobar Coastal Rd, Khobar 31982 (Saudi Arabia)

    2014-08-15

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  20. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    Energy Technology Data Exchange (ETDEWEB)

    Karakas, Hakki Muammer [Inonu University Medical Faculty, Turgut Ozal Medical Center, Department of Radiology, Malatya (Turkey); Celbis, Osman [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Forensic Medicine, Malatya (Turkey); Harma, Ahmet [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Orthopaedics and Traumatology, Malatya (Turkey); Alicioglu, Banu [Trakya University Medical Faculty, Department of Radiology, Edirne (Turkey); Trakya University Health Sciences Institute, Department of Anatomy, Edirne (Turkey)

    2011-05-15

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 {+-} 14.9 years) and 43 women (41.1 {+-} 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 {+-} 12.6 mm (77-138 mm) in men and 104.7 {+-} 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  1. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    International Nuclear Information System (INIS)

    Karakas, Hakki Muammer; Celbis, Osman; Harma, Ahmet; Alicioglu, Banu

    2011-01-01

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 ± 14.9 years) and 43 women (41.1 ± 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 ± 12.6 mm (77-138 mm) in men and 104.7 ± 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  2. Tomography

    International Nuclear Information System (INIS)

    Brown, B.H.; Barber, D.C.; Freeston, I.L.

    1983-01-01

    Tomography images of a body are constructed by placing a plurality of surface electrodes at spaced intervals on the body, causing currents to flow in the body (e.g. by applying a potential between each pair of electrodes in turn, or by induction), and measuring the potential between pairs of electrodes, calculating the potential expected in each case on the assumption that the body consists of a medium of uniform impedance, plotting the isopotentials corresponding to the calculated results to create a uniform image of the body, obtaining the ratio between the measured potential and the calculated potential in each case, and modifying the image in accordance with the respective ratios by increasing the assumed impedance along an isopotential in proportion to a ratio greater than unity or decreasing the assumed impedance in proportion to a ratio less than unity. The modified impedances along the isopotentials for each pair of electrodes are superimposed. The calculations are carried out using a computer and the plotting is carried out by a visual display unit and/or a print-out unit. (author)

  3. The effect of music on the anxiety levels of patients undergoing hysterosalpingography

    Energy Technology Data Exchange (ETDEWEB)

    Agwu, K.K. [Department of Medical Radiography and Radiological Sciences, Faculty of Health Sciences and Technology, University of Nigeria, Enugu Campus, Enugu (Nigeria)]. E-mail: kenagwu2000@yahoo.com; Okoye, I.J. [Department of Radiation Medicine, University of Nigeria Teaching Hospital, Enugu (Nigeria)

    2007-05-15

    Objectives: To determine the effect of music on the anxiety levels of patients undergoing a hysterosalpingography procedure. Patients and methods: One hundred hysterosalpingography referrals were randomly assigned to either the experimental or control group. Music chosen earlier by the patients was played during the hysterosalpingography procedure for the experimental group. The control group was studied without music. Certain physiological parameters and the State-Trait Anxiety Inventory were used to assess the patients' anxiety levels before and during the investigation. Patient's willingness to have a repeat procedure, should it become necessary, was also assessed in both groups as a measure of acceptability of the investigation. The z-test was used to analyze the results for any statistically significant differences between the experimental and the control groups. Results: The blood pressure (BP) monitored during the procedure was reduced in 31 (62%) of the patients in the experimental group compared to their pre-investigation values. Reduction in the pulse rate (PR) in 28 (56%) of the patients was also noted in the experimental group. On the other hand, the blood pressure of 37 (74%) of the patients and the pulse rate of 32 (64%) patients in the control group were increased from their pre-investigation values. The physiological parameters in the experimental group were significantly lower than the values in the control group during the investigation (p < 0.05). A comparison of the State-Trait Anxiety Inventory scores taken before and during the procedure shows significantly lower scores for the experimental group compared to those for the control group (p < 0.05). More patients, 41 (82%) in the experimental group were also willing to have a repeat procedure compared to 16 (32%) patients in the control. Conclusion: Music reduces the physiological and cognitive responses of anxiety in patients undergoing hysterosalpingography and can be harnessed for

  4. The effect of music on the anxiety levels of patients undergoing hysterosalpingography

    International Nuclear Information System (INIS)

    Agwu, K.K.; Okoye, I.J.

    2007-01-01

    Objectives: To determine the effect of music on the anxiety levels of patients undergoing a hysterosalpingography procedure. Patients and methods: One hundred hysterosalpingography referrals were randomly assigned to either the experimental or control group. Music chosen earlier by the patients was played during the hysterosalpingography procedure for the experimental group. The control group was studied without music. Certain physiological parameters and the State-Trait Anxiety Inventory were used to assess the patients' anxiety levels before and during the investigation. Patient's willingness to have a repeat procedure, should it become necessary, was also assessed in both groups as a measure of acceptability of the investigation. The z-test was used to analyze the results for any statistically significant differences between the experimental and the control groups. Results: The blood pressure (BP) monitored during the procedure was reduced in 31 (62%) of the patients in the experimental group compared to their pre-investigation values. Reduction in the pulse rate (PR) in 28 (56%) of the patients was also noted in the experimental group. On the other hand, the blood pressure of 37 (74%) of the patients and the pulse rate of 32 (64%) patients in the control group were increased from their pre-investigation values. The physiological parameters in the experimental group were significantly lower than the values in the control group during the investigation (p < 0.05). A comparison of the State-Trait Anxiety Inventory scores taken before and during the procedure shows significantly lower scores for the experimental group compared to those for the control group (p < 0.05). More patients, 41 (82%) in the experimental group were also willing to have a repeat procedure compared to 16 (32%) patients in the control. Conclusion: Music reduces the physiological and cognitive responses of anxiety in patients undergoing hysterosalpingography and can be harnessed for clinical

  5. Dual-Energy Computed Tomography in Stroke Imaging: Technical and Clinical Considerations of Virtual Noncontrast Images for Detection of the Hyperdense Artery Sign.

    Science.gov (United States)

    Winklhofer, Sebastian; Vittoria De Martini, Ilaria; Nern, Chrisitian; Blume, Iris; Wegener, Susanne; Pangalu, Athina; Valavanis, Antonios; Alkadhi, Hatem; Guggenberger, Roman

    The technical feasibility of virtual noncontrast (VNC) images from dual-energy computed tomography (DECT) for the detection of the hyperdense artery sign (HAS) in ischemic stroke patients was investigated. True noncontrast (TNC) scans of 60 patients either with or without HAS (n = 30 each) were investigated. Clot presence and characteristics were assessed on VNC images from DECT angiography and compared with TNC images. Clot characterization included the level of confidence for diagnosing HAS, a qualitative clot burden score, and quantitative attenuation (Hounsfield unit [HU]) measurements. Sensitivity, specificity, and accuracy of VNC for diagnosing HAS were 97%, 90%, and 93%, respectively. No significant differences were found regarding the diagnostic confidence (P = 0.18) and clot burden score (P = 0.071). No significant HU differences were found among vessels with HAS in VNC (56 ± 7HU) and TNC (57 ± 8HU) (P = 0.691) images. Virtual noncontrast images derived from DECT enable an accurate detection and characterization of HAS.

  6. The impact of different cone beam computed tomography and multi-slice computed tomography scan parameters on virtual three-dimensional model accuracy using a highly precise ex vivo evaluation method.

    Science.gov (United States)

    Matta, Ragai-Edward; von Wilmowsky, Cornelius; Neuhuber, Winfried; Lell, Michael; Neukam, Friedrich W; Adler, Werner; Wichmann, Manfred; Bergauer, Bastian

    2016-05-01

    Multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT) are indispensable imaging techniques in advanced medicine. The possibility of creating virtual and corporal three-dimensional (3D) models enables detailed planning in craniofacial and oral surgery. The objective of this study was to evaluate the impact of different scan protocols for CBCT and MSCT on virtual 3D model accuracy using a software-based evaluation method that excludes human measurement errors. MSCT and CBCT scans with different manufacturers' predefined scan protocols were obtained from a human lower jaw and were superimposed with a master model generated by an optical scan of an industrial noncontact scanner. To determine the accuracy, the mean and standard deviations were calculated, and t-tests were used for comparisons between the different settings. Averaged over 10 repeated X-ray scans per method and 19 measurement points per scan (n = 190), it was found that the MSCT scan protocol 140 kV delivered the most accurate virtual 3D model, with a mean deviation of 0.106 mm compared to the master model. Only the CBCT scans with 0.2-voxel resolution delivered a similar accurate 3D model (mean deviation 0.119 mm). Within the limitations of this study, it was demonstrated that the accuracy of a 3D model of the lower jaw depends on the protocol used for MSCT and CBCT scans. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  7. Periprosthetic Artifact Reduction Using Virtual Monochromatic Imaging Derived From Gemstone Dual-Energy Computed Tomography and Dedicated Software.

    Science.gov (United States)

    Reynoso, Exequiel; Capunay, Carlos; Rasumoff, Alejandro; Vallejos, Javier; Carpio, Jimena; Lago, Karen; Carrascosa, Patricia

    2016-01-01

    The aim of this study was to explore the usefulness of combined virtual monochromatic imaging and metal artifact reduction software (MARS) for the evaluation of musculoskeletal periprosthetic tissue. Measurements were performed in periprosthetic and remote regions in 80 patients using a high-definition scanner. Polychromatic images with and without MARS and virtual monochromatic images were obtained. Periprosthetic polychromatic imaging (PI) showed significant differences compared with remote areas among the 3 tissues explored (P remote tissues using monochromatic imaging with MARS (P = 0.053 bone, P = 0.32 soft tissue, and P = 0.13 fat). However, such differences were significant using PI with MARS among bone (P = 0.005) and fat (P = 0.02) tissues. All periprosthetic areas were noninterpretable using PI, compared with 11 (9%) using monochromatic imaging. The combined use of virtual monochromatic imaging and MARS reduced periprosthetic artifacts, achieving attenuation levels comparable to implant-free tissue.

  8. Simple improvement in the technique of hysterosalpingography achieving optimal imaging and avoiding possible complications

    International Nuclear Information System (INIS)

    Beyth, Y.; Navot, D.; Lax, E.

    1985-01-01

    A simple technique is reported in which oil-soluble contrast media (OSCM) are used with hysterosalpingography to investigate infertility in women due to uterine and tubal pathology. The advantages of OSCM as compared with water-soluble contrast media (WSCM) are described. Complications caused by intravasation of the OSCM into lymph vessels and veins are avoided by clearing the media at the end of the procedure. This also results in the immediate spread of the contrast media in the pelvic cavity with the result that delayed radiographs become superfluous and the radiation dose to the genitals is reduced. 4 references, 2 figures

  9. Utility of multidetector row computed tomography and virtual bronchoscopy in evaluation of hemoptysis due to lung cancer

    Directory of Open Access Journals (Sweden)

    Sherif A.A. Mohamed

    2016-01-01

    Conclusion: MDCT angiography is a useful and non invasive method that allows a rapid and detailed identification of abnormal vasculature responsible for hemoptysis in patients with lung cancer. MDCT-generated virtual bronchoscopy is an accurate, and non invasive method for evaluating obstructions, endoluminal masses, and external compressions in patients with hemoptysis due to lung cancer.

  10. Pyosalpinges after hysterosalpingography in a patient with lower genital tract infection and managed by laparoscopic surgery in a resource low tertiary hospital case report and literature review.

    Science.gov (United States)

    Egbe, Thomas Obinchemti; Kobenge, Fidelia Mbi; Arlette, Metogo Mbengono Junette; Belley-Priso, Eugene

    2018-01-01

    Pyosalpinges (a complication of pelvic inflammatory disease) is infection of the fallopian tubes and the morbidity associated with it has major health implications. We are reporting a case of pyosalpinges diagnosed after hysterosalpingography and managed by laparoscopic surgery at the Douala General Hospital, Cameroon. A 29-year-old single woman, an assistant nurse of the Douala tribe in Cameroon. She is G1P0010 and came to our attention because of secondary infertility of three years duration. She has a history consistent with four lifetime sexual partners, self-medication for chlamydia trachomatis infection and induced abortion by dilatation and aspiration. Furthermore, she is HIV positive and had an ultrasound scan suggestive of bilateral hydrosalpinges. After a hysterosalpingography examination she developed painless muco-purulent vaginal discharge and bilateral adnexal tenderness on bimanual examination suggestive of pyosalpinges. Vaginal and cervical cultures isolated Ureaplasma urealyticum and Gardnerella vaginalis sensitive to ofloxacin and metronidazole, respectively.At laparoscopy, bilateral pyosalpinges, pelvic adhesions and peri-hepatic adhesions were found. Bilateral salpingectomy with adhesiolysis including lysis of perihepatic adhesions and peritoneal toileting was done. She was discharged from hospital 72 h later and her hospital stay was uneventful. She was counseled for in-vitro fertilization and to register in the national HIV treatment programme. Her husband was prescribed ofloxacin empirically. Antimicrobial prophylaxis should be given to patients prior to HSG, especially those with a history of chlamydia or evidence of hydrosalpinges. There should also be universal STI testing in high risk and HIV positive patients or the danger for suboptimal antibiotic usage in areas where self-medication is common.In resource-low tertiary hospitals where computed tomography or magnetic resonance imaging is not readily available and/or affordable, clinical

  11. Dual-energy computed tomography in patients with cutaneous malignant melanoma: Comparison of noise-optimized and traditional virtual monoenergetic imaging.

    Science.gov (United States)

    Martin, Simon S; Wichmann, Julian L; Weyer, Hendrik; Albrecht, Moritz H; D'Angelo, Tommaso; Leithner, Doris; Lenga, Lukas; Booz, Christian; Scholtz, Jan-Erik; Bodelle, Boris; Vogl, Thomas J; Hammerstingl, Renate

    2017-10-01

    The aim of this study was to investigate the impact of noise-optimized virtual monoenergetic imaging (VMI+) reconstructions on quantitative and qualitative image parameters in patients with cutaneous malignant melanoma at thoracoabdominal dual-energy computed tomography (DECT). Seventy-six patients (48 men; 66.6±13.8years) with metastatic cutaneous malignant melanoma underwent DECT of the thorax and abdomen. Images were post-processed with standard linear blending (M_0.6), traditional virtual monoenergetic (VMI), and VMI+ technique. VMI and VMI+ images were reconstructed in 10-keV intervals from 40 to 100keV. Attenuation measurements were performed in cutaneous melanoma lesions, as well as in regional lymph node, subcutaneous and in-transit metastases to calculate objective signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Five-point scales were used to evaluate overall image quality and lesion delineation by three radiologists with different levels of experience. Objective indices SNR and CNR were highest at 40-keV VMI+ series (5.6±2.6 and 12.4±3.4), significantly superior to all other reconstructions (all Ptraditional VMI in patients with cutaneous malignant melanoma at thoracoabdominal DECT. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Study on multi-detector computed tomography in the virtual endoscope mode to phantom of saliva gland duct application. Image quality evaluation of geometry

    International Nuclear Information System (INIS)

    Ozawa, Tomonori; Innami, Hisashi; Oyake, Reira; Shinohara, Yuki; Yamaaki, Fumi; Koizumi, Nobuhide; Okumura, Yasuhiko

    2009-01-01

    The diagnosis ability of the radiographic imaging has been greatly improved by the advent of multi-detector computed tomography (MDCT), Which is now a the prerequisite to the diagnosis and treatment of a variety of diseases. MDCT conducted in the virtual endoscope mode can be used for various image compositions, and the space in a structure such as the large intestines can be visualized similarly as with an actual endoscope. Using a phantom of a salivary gland duct, I performed the image analysis to determine whether this endoscope mode could able to be applied to the oral cavity. I searched for the optimum conditions and the best position for taking pictures, and evaluated whether the salivary gland ducts could be reproducibly imitated by the phantom. Modulation transfer function (MTF), Wiener spectrum (WS) analysis were used to examined the utility of MDCT in the virtual endoscope mode for use in the oral cavity. As a result, the following conclusions were made: The best image was obtained within 40 mm from the center part of the gantry by the MTF and the WS analyses. Decreases in the MTF and the WS as the decrease were seen at 20 mAs and 80 kV, and the decrease were seen in the sharpness of the image decreased as the value of the reconstruction function became smaller. The image was somewhat distorted when pictures were taken of the parallel or the direction of the slice by the inclination within 90 deg±15 deg as much as possible Z axially for running of the duct in the evaluation of internal reproducibility. The influence was admitted to go out easily in an inside form as the inside diameter became thin. The salivary gland phantom was evaluated geometrically by MDCT in the virtual endoscope mode, and the optimal conditions were obtained from the above-mentioned results. The utility of MDCT in the mode was thus suggested. (author)

  13. Is hysterosalpingography able to diagnose all uterine malformations correctly? A retrospective study

    International Nuclear Information System (INIS)

    Braun, Petra; Grau, Francisco Vercher; Pons, Raul Mut; Enguix, Daniel Perez

    2005-01-01

    Background: Muellerian duct anomalies are an uncommon but often a treatable cause of infertility. Material and methods: From January 2002 until November 2003, a total of 705 hysterosalpingographies were realised of which 658 were analysed retrospectively in order to determine the importance of uterine malformations in infertile and sterile patients. In ten cases, the results of hysterosalpingography were compared with hysteroscopy and laparoscopy. Results: The frequency of uterine malformations in infertile and sterile women was 10%. In this population, arcuate uterus (57.6%) was the most common malformation, followed by subseptate uterus (18.2%), uterus bicornis unicollis (10.6%), uterus bicornis bicollis (3.0%), septate uterus (6.1%), unicornuate uterus (3.0%) and unicornuate uterus with double vagina (1.5%). Discussion: Our bibliographic research confirmed that arcuate uterus is the most frequent congenital malformation, but in gestations it does not show a significantly reduced live birth rate. Nevertheless, the septate uterus presents an important decrease of live birth rate that can be improved significantly by doing hysteroscopic metroplasty. As this is a completely different surgical intervention compared to bicornuate uterus, a correct diagnosis is very important. Differentiation of these two malformations is quite difficult by hysterosalpingographic exploration, wherefore an additional exploration by means of endovaginal or three-dimensional ultrasound is recommended

  14. Is hysterosalpingography able to diagnose all uterine malformations correctly? A retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Petra; Grau, Francisco Vercher; Pons, Raul Mut; Enguix, Daniel Perez

    2005-02-01

    Background: Muellerian duct anomalies are an uncommon but often a treatable cause of infertility. Material and methods: From January 2002 until November 2003, a total of 705 hysterosalpingographies were realised of which 658 were analysed retrospectively in order to determine the importance of uterine malformations in infertile and sterile patients. In ten cases, the results of hysterosalpingography were compared with hysteroscopy and laparoscopy. Results: The frequency of uterine malformations in infertile and sterile women was 10%. In this population, arcuate uterus (57.6%) was the most common malformation, followed by subseptate uterus (18.2%), uterus bicornis unicollis (10.6%), uterus bicornis bicollis (3.0%), septate uterus (6.1%), unicornuate uterus (3.0%) and unicornuate uterus with double vagina (1.5%). Discussion: Our bibliographic research confirmed that arcuate uterus is the most frequent congenital malformation, but in gestations it does not show a significantly reduced live birth rate. Nevertheless, the septate uterus presents an important decrease of live birth rate that can be improved significantly by doing hysteroscopic metroplasty. As this is a completely different surgical intervention compared to bicornuate uterus, a correct diagnosis is very important. Differentiation of these two malformations is quite difficult by hysterosalpingographic exploration, wherefore an additional exploration by means of endovaginal or three-dimensional ultrasound is recommended.

  15. Estimate of worker and patient exposures and quality control in hysterosalpingography exams

    International Nuclear Information System (INIS)

    Rodrigues, Barbara Beatriz Dias

    2006-06-01

    Hysterosalpingography (HSG) is a relatively frequent radiological procedure, which is used to access and study the uterine cavity and the tubary permeability. The estimate of the radiation doses received by the patients, and of the associated risks, has become of great interest in recent years. The importance in evaluating the received doses becomes even higher when the gonads region is irradiated; as in the case of hysterosalpingography, where the patients are relatively young, existing a high probability of future pregnancy. In HSG procedure the physician stays beside the patient, being also exposed. The purpose of this study was to analyze, during HSG procedures, the exposition of patients, measuring the kerma-area (P K,A ) product by using an ionization chamber of big area, to evaluate the doses received by the radiologist using thermoluminescent dosemeters and to evaluate the quality of image by means of qualitative methods. The results gotten during the accompaniment of 86 examinations had been the following ones: the average P K,A was 706 ± 388 cGy.cm 2 , to an average exposition time of 2 ± 1 minutes. In order to optimize the exposure of patients and workers, the time of scopy and the number of images should be reduced, whenever it is possible. Due to the significant values of equivalent dose received by the lens, the use of plumbiferous eyeglasses is recommended. (author)

  16. Virtual cystoscopy, computed tomography urography and optical cystoscopy for the detection and follow-up for bladder cancer.

    Science.gov (United States)

    Ibáñez Muñoz, D; Quintana Martínez, I; Fernández Militino, A; Sánchez Zalabardo, D; Sarria Octavio de Toledo, L; Cozcolluela Cabrejas, R

    To evaluate the utility of virtual cystoscopy (VC) performed with CT urography in patients being studied under gross hematuria or patients being followed-up after a previous bladder cancer and compare the results with those obtained with gold standard technique (optical cystoscopy). Retrospective study of 117 patients who were referred for VC by the Urology Department between May 2014 and May 2015. Those patients presented with gross hematuria or they were previously treated patients from bladder cancer being followed up. These patients were evaluated with MDCT and virtual cystoscopy after distending the bladder with air. The results were compared with those obtained with optical cystoscopy which was performed no more than a week after. The global sensitivity and specificity of VC were 81,8 and 92,1%. Aditional findings detected in CT urography were an aortic dissection, urinary lithiasis and colonic metastasis. VC seems an useful technique in the diagnosis and follow-up for bladder cancer with a good correlation with OC. The main limitations are the impossibility of biopsy during the procedure and the detection of erythematous lesions. Collateral findings can be detected performed with CT urography although the high radiation exposure does not recommend their combined use. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Usefulness of Computed Tomography in pre-surgical evaluation of maxillo-facial pathology with rapid prototyping and surgical pre-planning by virtual reality

    International Nuclear Information System (INIS)

    Toso, Francesco; Zuiani, Chiara; Vergendo, Maurizio; Bazzocchi, Massimo; Salvo, Iolanda; Robiony, Massimo; Politi, Massimo

    2005-01-01

    Purpose. To validate a protocol for creating virtual models to be used in the construction of solid prototypes useful for the planning-simulation of maxillo-facial surgery, in particular for very complex anatomical and pathologic problems. To optimize communications between the radiology, engineering and surgical laboratories. Methods and materials. We studied 16 patients with different clinical problems of the maxillo-facial district. Exams were performed with multidetector computed tomography (MDCT) and single slice computed tomography (SDCT) with axial scans and collimation of 0.5-2 mm, and reconstruction interval of 1 mm. Subsequently we performed 2D multiplanar reconstructions and 3D volume-rendering reconstructions. We exported the DICOM images to the engineering laboratory, to recognize and isolate the bony structures by software. With these data the solid prototypes were generated using stereolitography. To date, surgery has been preformed on 12 patients after simulation of the procedure on the stereolitography model. Results. The solid prototypes constructed in the difficult cases were sufficiently detailed despite problems related to the artefacts generated by dental fillings and prostheses. In the remaining cases the MPR/3D images were sufficiently detailed for surgical planning. The surgical results were excellent in all patients who underwent surgery, and the surgeons were satisfied with the improvement in quality and the reduction in time required for the procedure. Conclusions. MDCT enables rapid prototyping using solid replication, which was very helpful in maxillofacial surgery, despite problems related to artifacts due to dental fillings and prosthesis within the acquisition field; solutions for this problem are work in progress. The protocol used for communication between the different laboratories was valid and reproducible [it

  18. A comparative study of hysterosalpingography and endoscopy/laparotomy in infertile patients

    International Nuclear Information System (INIS)

    Nielsen, D.T.; Rasmussen, F.; Justesen, P.

    1987-01-01

    A comparison of hysterosalpingography (HSG), using Lipiodol ultrafluid as contrast medium, with endoscopy/laparotomy in the evaluation of the tubal function in 124 infertile women is presented. There was agreement between the results of both methods in 73.4% of the patients. The false-negative rate was 2.4% and the false-positive rate was 8.9%. Complications in the form of intravasation were seen in three patients but none of them had any symptoms. The conception rate was 35% in the subgroup of patients with normal HSG. The authors recommended the continuous use of HSG in the overall evaluation of infertile patients. It is recommended to use oil-soluble contrast media because of its high diagnostic accuracy, low frequency of complications and its therapeutic advantages. (orig.)

  19. Radiation dose in hysterosalpingography: modern 100mm fluorography vs. full-scale radiography

    International Nuclear Information System (INIS)

    Seppaenen, S.; Lehtinen, E.; Holli, H.

    1978-01-01

    Radiation doses of modern 100 mm fluorography and full-scale radiography were compared experimentally and applied to hysterosalpingography. It was determined that 100 mm fluorography reduced the doses by 28 to 29 percent per exposure and 37 to 47 percent per examination compared with full-scale radiography performed with fast tungstate screens in identical conditions (70 to 80 kV, 400 mA). The dose during one minute of videofluoroscopy was equivalent to the doses produced by one exposure in full-scale filming and three to four exposures in 100 mm filming. Although electronic magnification in 100 mm fluorography increases the doses by two or threefold, these are still less than the doses in full-scale radiography

  20. Virtual non-contrast computer tomography (CT) with spectral CT as an alternative to conventional unenhanced CT in the assessment of gastric cancer.

    Science.gov (United States)

    Tian, Shi-Feng; Liu, Ai-Lian; Wang, He-Qing; Liu, Jing-Hong; Sun, Mei-Yu; Liu, Yi-Jun

    2015-01-01

    The purpose of this study was to evaluate computed tomography (CT) virtual non-contrast (VNC) spectral imaging for gastric carcinoma. Fifty-two patients with histologically proven gastric carcinomas underwent gemstone spectral imaging (GSI) including non-contrast and contrast-enhanced hepatic arterial, portal venous, and equilibrium phase acquisitions prior to surgery. VNC arterial phase (VNCa), VNC venous phase (VNCv), and VNC equilibrium phase (VNCe) images were obtained by subtracting iodine from iodine/water images. Images were analyzed with respect to image quality, gastric carcinoma-intragastric water contrast-to-noise ratio (CNR), gastric carcinoma-perigastric fat CNR, serosal invasion, and enlarged lymph nodes around the lesions. Carcinoma-water CNR values were significantly higher in VNCa, VNCv, and VNCe images than in normal CT images (2.72, 2.60, 2.61, respectively, vs 2.35, p≤0.008). Carcinoma- perigastric fat CNR values were significantly lower in VNCa, VNCv, and VNCe images than in normal CT images (7.63, 7.49, 7.32, respectively, vs 8.48, pVNC arterial phase images may be a surrogate for conventional non-contrast CT images in gastric carcinoma evaluation.

  1. Meta-analysis of dual-energy computed tomography virtual non-calcium imaging to detect bone marrow edema.

    Science.gov (United States)

    Li, Mou; Qu, Yali; Song, Bin

    2017-10-01

    This meta-analysis aimed to evaluate the accuracy of dual-energy CT (DECT) virtual non-calcium (VNC) imaging for the detection of bone marrow edema (BME). A systematic literature search up to March 2017 was performed to find relevant original studies. Two reviewers independently selected studies, assessed literature quality, and extracted data. Pooled sensitivity, specificity, area under receiver operating characteristic (AUROC) curve, and other measures of DECT accuracy for detecting BME were calculated using random effects models. Risk of heterogeneity was assessed for the appropriateness of meta-analysis. Fourteen studies involving 2205 regions of vertebrae, hips, knees, and ankles were included. To evaluate the accuracy of BME detection using DECT, calculations were performed to obtain a pooled sensitivity of 0.812 (95% confidence interval [CI], 0.780-0.841) and specificity of 0.951 (95% CI, 0.940-0.960). The AUROC value was 0.9635. The major potential cause of heterogeneity was bone position. No significant publication bias was present. DECT VNC imaging gives very good diagnostic performance for BME detection and will likely be an important and common modality for acute assessment in the future. Copyright © 2017. Published by Elsevier B.V.

  2. The value of hysterosalpingography using non-ionic contrast agent combined with low-tensive drug in diagnosis of infertility

    International Nuclear Information System (INIS)

    Deng Qiwei; Liu Xiaojun; Shi Jianfen; Jiang Guohua; Ye Jinqing; Shen Jun; Song Ting

    2009-01-01

    Objective: To analyze the value of nonionic contrast agent combined with low tensive drug in the hysterosalpingography in diagnosis of infertility. Methods: 203 patients with infertility were randomly classified into two groups. Group 1 contained 108 patients administrated intramuscularly anisodamine (654-2) 30 minutes before hysterosalpingography. 95 patients in group 2 did not use 654-2. Non-ionic contrast agent was used in all patients. The image quality and post-contrast displaying status of uterus and uterine tube between the two groups were analyzed. Results: No allergic response occurred in all patients. The image quality and post-contrast displaying status of uterus and uterine tube of group 1 were obviously superior to that of group 2 (P<0.01). Conclusion: Hysterosalpingography clearly showed lesions of uterus and uterine tube when using non-ionic contrast agent combined with low-tensive drug. It is more safety with less side effects. The contraction of uterine tube can be relieved by the low-tensive drug effectively, so as to decrease the false positive rate, raise the diagnostic accuracy, and lessen patients sufferings. It is deserved to be applied generally. (authors)

  3. Virtual forensic entomology: improving estimates of minimum post-mortem interval with 3D micro-computed tomography.

    Science.gov (United States)

    Richards, Cameron S; Simonsen, Thomas J; Abel, Richard L; Hall, Martin J R; Schwyn, Daniel A; Wicklein, Martina

    2012-07-10

    We demonstrate how micro-computed tomography (micro-CT) can be a powerful tool for describing internal and external morphological changes in Calliphora vicina (Diptera: Calliphoridae) during metamorphosis. Pupae were sampled during the 1st, 2nd, 3rd and 4th quarter of development after the onset of pupariation at 23 °C, and placed directly into 80% ethanol for preservation. In order to find the optimal contrast, four batches of pupae were treated differently: batch one was stained in 0.5M aqueous iodine for 1 day; two for 7 days; three was tagged with a radiopaque dye; four was left unstained (control). Pupae stained for 7d in iodine resulted in the best contrast micro-CT scans. The scans were of sufficiently high spatial resolution (17.2 μm) to visualise the internal morphology of developing pharate adults at all four ages. A combination of external and internal morphological characters was shown to have the potential to estimate the age of blowfly pupae with a higher degree of accuracy and precision than using external morphological characters alone. Age specific developmental characters are described. The technique could be used as a measure to estimate a minimum post-mortem interval in cases of suspicious death where pupae are the oldest stages of insect evidence collected. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  4. Virtual non-contrast in second-generation, dual-energy computed tomography: Reliability of attenuation values

    International Nuclear Information System (INIS)

    Toepker, Michael; Moritz, Thomas; Krauss, Bernhard; Weber, Michael; Euller, Gordon; Mang, Thomas; Wolf, Florian; Herold, Christian J.; Ringl, Helmut

    2012-01-01

    Purpose: To evaluate the reliability of attenuation values in virtual non-contrast images (VNC) reconstructed from contrast-enhanced, dual-energy scans performed on a second-generation dual-energy CT scanner, compared to single-energy, non-contrast images (TNC). Materials and methods: Sixteen phantoms containing a mixture of contrast agent and water at different attenuations (0–1400 HU) were investigated on a Definition Flash-CT scanner using a single-energy scan at 120 kV and a DE-CT protocol (100 kV/SN140 kV). For clinical assessment, 86 patients who received a dual-phase CT, containing an unenhanced single-energy scan at 120 kV and a contrast enhanced (110 ml Iomeron 400 mg/ml; 4 ml/s) DE-CT (100 kV/SN140 kV) in an arterial (n = 43) or a venous phase, were retrospectively analyzed. Mean attenuation was measured within regions of interest of the phantoms and in different tissue types of the patients within the corresponding VNC and TNC images. Paired t-tests and Pearson correlation were used for statistical analysis. Results: For all phantoms, mean attenuation in VNC was 5.3 ± 18.4 HU, with respect to water. In 86 patients overall, 2637 regions were measured in TNC and VNC images, with a mean difference between TNC and VNC of −3.6 ± 8.3 HU. In 91.5% (n = 2412) of all cases, absolute differences between TNC and VNC were under 15 HU, and, in 75.3% (n = 1986), differences were under 10 HU. Conclusions: Second-generation dual-energy CT based VNC images provide attenuation values close to those of TNC. To avoid possible outliers multiple measurements are recommended especially for measurements in the spleen, the mesenteric fat, and the aorta.

  5. Virtual non-contrast in second-generation, dual-energy computed tomography: reliability of attenuation values.

    Science.gov (United States)

    Toepker, Michael; Moritz, Thomas; Krauss, Bernhard; Weber, Michael; Euller, Gordon; Mang, Thomas; Wolf, Florian; Herold, Christian J; Ringl, Helmut

    2012-03-01

    To evaluate the reliability of attenuation values in virtual non-contrast images (VNC) reconstructed from contrast-enhanced, dual-energy scans performed on a second-generation dual-energy CT scanner, compared to single-energy, non-contrast images (TNC). Sixteen phantoms containing a mixture of contrast agent and water at different attenuations (0-1400 HU) were investigated on a Definition Flash-CT scanner using a single-energy scan at 120 kV and a DE-CT protocol (100 kV/SN140 kV). For clinical assessment, 86 patients who received a dual-phase CT, containing an unenhanced single-energy scan at 120 kV and a contrast enhanced (110 ml Iomeron 400 mg/ml; 4 ml/s) DE-CT (100 kV/SN140 kV) in an arterial (n=43) or a venous phase, were retrospectively analyzed. Mean attenuation was measured within regions of interest of the phantoms and in different tissue types of the patients within the corresponding VNC and TNC images. Paired t-tests and Pearson correlation were used for statistical analysis. For all phantoms, mean attenuation in VNC was 5.3±18.4 HU, with respect to water. In 86 patients overall, 2637 regions were measured in TNC and VNC images, with a mean difference between TNC and VNC of -3.6±8.3 HU. In 91.5% (n=2412) of all cases, absolute differences between TNC and VNC were under 15HU, and, in 75.3% (n=1986), differences were under 10 HU. Second-generation dual-energy CT based VNC images provide attenuation values close to those of TNC. To avoid possible outliers multiple measurements are recommended especially for measurements in the spleen, the mesenteric fat, and the aorta. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  6. Dual-Energy Computed Tomography Angiography of the Lower Extremity Runoff: Impact of Noise-Optimized Virtual Monochromatic Imaging on Image Quality and Diagnostic Accuracy.

    Science.gov (United States)

    Wichmann, Julian L; Gillott, Matthew R; De Cecco, Carlo N; Mangold, Stefanie; Varga-Szemes, Akos; Yamada, Ricardo; Otani, Katharina; Canstein, Christian; Fuller, Stephen R; Vogl, Thomas J; Todoran, Thomas M; Schoepf, U Joseph

    2016-02-01

    The aim of this study was to evaluate the impact of a noise-optimized virtual monochromatic imaging algorithm (VMI+) on image quality and diagnostic accuracy at dual-energy computed tomography angiography (CTA) of the lower extremity runoff. This retrospective Health Insurance Portability and Accountability Act-compliant study was approved by the local institutional review board. We evaluated dual-energy CTA studies of the lower extremity runoff in 48 patients (16 women; mean age, 63.3 ± 13.8 years) performed on a third-generation dual-source CT system. Images were reconstructed with standard linear blending (F_0.5), VMI+, and traditional monochromatic (VMI) algorithms at 40 to 120 keV in 10-keV intervals. Vascular attenuation and image noise in 18 artery segments were measured; signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used to subjectively evaluate vascular attenuation and image noise. In a subgroup of 21 patients who underwent additional invasive catheter angiography, diagnostic accuracy for the detection of significant stenosis (≥50% lumen restriction) of F_0.5, 50-keV VMI+, and 60-keV VMI data sets were assessed. Objective image quality metrics were highest in the 40- and 50-keV VMI+ series (SNR: 20.2 ± 10.7 and 19.0 ± 9.5, respectively; CNR: 18.5 ± 10.3 and 16.8 ± 9.1, respectively) and were significantly (all P traditional VMI technique and standard linear blending for evaluation of the lower extremity runoff using dual-energy CTA.

  7. Virtual landmarks

    Science.gov (United States)

    Tong, Yubing; Udupa, Jayaram K.; Odhner, Dewey; Bai, Peirui; Torigian, Drew A.

    2017-03-01

    Much has been published on finding landmarks on object surfaces in the context of shape modeling. While this is still an open problem, many of the challenges of past approaches can be overcome by removing the restriction that landmarks must be on the object surface. The virtual landmarks we propose may reside inside, on the boundary of, or outside the object and are tethered to the object. Our solution is straightforward, simple, and recursive in nature, proceeding from global features initially to local features in later levels to detect landmarks. Principal component analysis (PCA) is used as an engine to recursively subdivide the object region. The object itself may be represented in binary or fuzzy form or with gray values. The method is illustrated in 3D space (although it generalizes readily to spaces of any dimensionality) on four objects (liver, trachea and bronchi, and outer boundaries of left and right lungs along pleura) derived from 5 patient computed tomography (CT) image data sets of the thorax and abdomen. The virtual landmark identification approach seems to work well on different structures in different subjects and seems to detect landmarks that are homologously located in different samples of the same object. The approach guarantees that virtual landmarks are invariant to translation, scaling, and rotation of the object/image. Landmarking techniques are fundamental for many computer vision and image processing applications, and we are currently exploring the use virtual landmarks in automatic anatomy recognition and object analytics.

  8. Role of 3.0 Tesla magnetic resonance hysterosalpingography in the diagnostic work-up of female infertility.

    Science.gov (United States)

    Cipolla, Valentina; Guerrieri, Daniele; Pietrangeli, Daniela; Santucci, Domiziana; Argirò, Renato; de Felice, Carlo

    2016-09-01

    Imaging evaluation plays a crucial role in the diagnostic work-up of female infertility. In recent years, the possibility to evaluate tubal patency using 1.5 Tesla magnetic resonance (1.5T MR) has been studied. To assess the feasibility of 3.0 Tesla magnetic resonance (3.0T MR) hysterosalpingography and its role in the diagnostic work-up of female infertility and to evaluate if this fast "one-stop-shop" imaging approach should be proposed as a first-line examination. A total of 116 infertile women were enrolled in this prospective study; all underwent 3.0T MR hysterosalpingography. After standard imaging of the pelvis, tubal patency was assessed by acquiring 3D dynamic time-resolved T1-weighted (T1W) sequences during manual injection of 4-5 mL of contrast solution consisting of gadolinium and normal sterile saline. Images were evaluated by two radiologists with different experience in MR imaging (MRI). The examination was successfully completed in 96.5% of cases, failure rate was 3.5%. Dynamic sequences showed bilateral tubal patency in 64.3%, unilateral tubal patency in 25.9%, and bilateral tubal occlusion in 9.8%. Extratubal abnormalities were found in 69.9% of patients. Comprehensive analysis of morphological and dynamic sequences showed extratubal abnormalities in 43.1% of patients with bilateral tubal patency. 3.0T MR hysterosalpingography is a feasible, simple, fast, safe, and well-tolerated examination, which allows evaluation of tubal patency and other pelvic causes of female infertility in a single session, and it may thus represent a "one-stop-shop" solution in female infertility diagnostic work-up. © The Foundation Acta Radiologica 2015.

  9. Hyperthyroidism secondary to hysterosalpingography: an extremely rare complication: A case report.

    Science.gov (United States)

    Ma, Guotao; Mao, Rui; Zhai, Haixin

    2016-12-01

    Hysterosalpingography (HSG), a standard procedure for the evaluation of women with infertility and repetitive pregnancy loss, is associated with complications such as uterine perforation, infection, allergic reactions, syncope, hemorrhage and shock, and pulmonary or retinal embolus. However, hyperthyroidism has not been reported as one of its complications. We report the case of a 33-year-old euthyroid woman who presented to our hospital with palpitation, hand tremor, fatigue, and excessive sweating after HSG. Thyroid function tests revealed a thyroid stimulating hormone (TSH) level of 0.012 μIU/mL (range 0.38-4.34 μIU/mL), free T4 of 2.886 ng/dL (range 0.81-1.89 ng/dL), and free T3 levels of 9.4 pg/mL (range 1.80-4.10 pg/mL), and antithyroglobulin antibody of 31.78 IU/mL (range hyperthyroidism (IIH), but was not treated with antithyroid drugs. She has spontaneously recovered and is pregnant currently. This is the first reported case of overt IIH caused by HSG in a euthyroid patient without risk factors. It suggests that HSG also leads to excessive iodine absorption, which induces secondary hyperthyroidism.

  10. Effectiveness of paracervical block for pain relief in women undergoing hysterosalpingography

    Directory of Open Access Journals (Sweden)

    Shikha Jain

    2016-01-01

    Full Text Available Objectives: To evaluate the potential benefit, in terms of pain relief, of the paracervical block with 2% lignocaine in women undergoing hysterosalpingography (HSG. Study Design: This study was a prospective randomized controlled study. Settings: This study was conducted in infertility clinic of a tertiary care center. Materials and Methods: Four hundred and six patients undergoing HSG as a part of infertility evaluation were included in the study. These women were randomized into two groups: Group I received paracervical block with 2% lignocaine at the time of HSG (n = 53 and Group II (n = 53 served as control. Hyoscine (10 mg oral tablet was given to all the patients 30 min before the procedure. Pain perception during the procedure was analyzed by the patient between 0 and 10 on a numeric rating scale, immediately after HSG. Results: The baseline demographic characteristics of participants in two groups were similar. Mean pain score immediately after HSG in the study group and control group was 4.84 ± 2.56 and 5.21 ± 1.89, respectively (P = 0.21. Conclusions : There is no benefit of paracervical block with 2% lignocaine, in terms of pain relief, in women undergoing HSG.

  11. Can hysterosalpingocontrast-sonography replace hysterosalpingography in the assessment of tubal subfertility?

    Science.gov (United States)

    Dijkman, A B; Mol, B W; van der Veen, F; Bossuyt, P M; Hogerzeil, H V

    2000-07-01

    Hysterosalpingo-contrastsonography (HyCoSy) is a new method for assessing tubal patency using transvaginal ultrasound. It is thought to have several advantages over conventional hysterosalpingography (HSG). We prospectively evaluated the performance of HyCoSy and HSG in the diagnosis of tubal pathology. One-hundred consecutive subfertile women underwent both HyCoSy and HSG in randomised order. Results of both tests were related to findings at laparoscopy with dye, which was used as the reference test. Each woman was asked to score the pain exsperienced at both procedures on a visual analogue scale. When laparoscopy with dye was used as reference test, the likelihood ratios of HyCoSy were slightly inferior to those obtained for HSG. Since the performance of HyCoSy was dependent on experience, the results were recalculated omitting the 50 initial procedures from the analysis. In that calculation, results of HyCoSy and HSG were comparable. There were no differences in pain experienced during the procedure, as there appeared also to be no differences in patient preferences. There appear to be no strong arguments either to replace HSG by HyCoSy, or to reject the use of HyCoSy. Both procedures can be used in the evaluation of tubal pathology.

  12. Can hysterosalpingocontrast-sonography replace hysterosalpingography in the assessment of tubal subfertility?

    Energy Technology Data Exchange (ETDEWEB)

    Dijkman, Antonius B.; Mol, Ben W.J.; Veen, Fulco van der; Bossuyt, P.M.M.; Hogerzeil, Hendricus V

    2000-07-01

    Introduction: Hysterosalpingo-contrastsonography (HyCoSy) is a new method for assessing tubal patency using transvaginal ultrasound. It is thought to have several advantages over conventional hysterosalpingography (HSG). We prospectively evaluated the performance of HyCoSy and HSG in the diagnosis of tubal pathology. Methods and patients: One-hundred consecutive subfertile women underwent both HyCoSy and HSG in randomised order. Results of both tests were related to findings at laparoscopy with dye, which was used as the reference test. Each woman was asked to score the pain exsperienced at both procedures on a visual analogue scale. Results: When laparoscopy with dye was used as reference test, the likelihood ratios of HyCoSy were slightly inferior to those obtained for HSG. Since the performance of HyCoSy was dependent on experience, the results were recalculated omitting the 50 initial procedures from the analysis. In that calculation, results of HyCoSy and HSG were comparable. There were no differences in pain experienced during the procedure, as there appeared also to be no differences in patient preferences. Conclusion: There appear to be no strong arguments either to replace HSG by HyCoSy, or to reject the use of HyCoSy. Both procedures can be used in the evaluation of tubal pathology.

  13. Can hysterosalpingocontrast-sonography replace hysterosalpingography in the assessment of tubal subfertility?

    International Nuclear Information System (INIS)

    Dijkman, Antonius B.; Mol, Ben W.J.; Veen, Fulco van der; Bossuyt, P.M.M.; Hogerzeil, Hendricus V.

    2000-01-01

    Introduction: Hysterosalpingo-contrastsonography (HyCoSy) is a new method for assessing tubal patency using transvaginal ultrasound. It is thought to have several advantages over conventional hysterosalpingography (HSG). We prospectively evaluated the performance of HyCoSy and HSG in the diagnosis of tubal pathology. Methods and patients: One-hundred consecutive subfertile women underwent both HyCoSy and HSG in randomised order. Results of both tests were related to findings at laparoscopy with dye, which was used as the reference test. Each woman was asked to score the pain exsperienced at both procedures on a visual analogue scale. Results: When laparoscopy with dye was used as reference test, the likelihood ratios of HyCoSy were slightly inferior to those obtained for HSG. Since the performance of HyCoSy was dependent on experience, the results were recalculated omitting the 50 initial procedures from the analysis. In that calculation, results of HyCoSy and HSG were comparable. There were no differences in pain experienced during the procedure, as there appeared also to be no differences in patient preferences. Conclusion: There appear to be no strong arguments either to replace HSG by HyCoSy, or to reject the use of HyCoSy. Both procedures can be used in the evaluation of tubal pathology

  14. Improving Rates of Post-Essure Hysterosalpingography in an Urban Population Using Electronic Tracking Reminders.

    Science.gov (United States)

    Virginia Hu, Yu-Han; Arora, Kavita Shah

    2017-02-01

    To demonstrate the efficacy of electronic reminders for follow-up hysterosalpingography (HSG) after Essure hysteroscopic sterilization in an urban tertiary care hospital obstetrics and gynecology practice. Retrospective cohort study (Canadian Task Force classification II-3). Obstetrics and gynecology practice at a university-affiliated urban tertiary care teaching hospital. Two hundred and fifty patients who underwent Essure hysteroscopic sterilization between June 2011 and July 2014. Implementation of electronic reminders for the office staff. Two hundred and fifty of 259 patients (96.5%) underwent Essure hysteroscopic sterilization and successful placement of coils into bilateral Fallopian tubes. Among these 250 patients, 135 (54%) returned for HSG at 3 months post-Essure as advised at the time of procedure. The use of electronic reminders prompted another 45 patients (18%) to return for HSG, improving the total post-Essure follow-up rate to 72%. Electronic reminders for the office staff of an urban tertiary care hospital's obstetrics and gynecology practice is an effective method for improving the rate of post-Essure HSG. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  15. Dual-energy computed tomography to assess tumor response to hepatic radiofrequency ablation: potential diagnostic value of virtual noncontrast images and iodine maps.

    Science.gov (United States)

    Lee, Su Hyun; Lee, Jeong Min; Kim, Kyung Won; Klotz, Ernst; Kim, Se Hyung; Lee, Jae Young; Han, Joon Koo; Choi, Byung Ihn

    2011-02-01

    to determine the value of dual-energy (DE) scanning with virtual noncontrast (VNC) images and iodine maps in the evaluation of therapeutic response to radiofrequency ablation (RFA) for hepatic tumors. a total of 75 patients with hepatic tumors and who underwent DE computed tomography (CT) after RFA, were enrolled in this study. Our DE CT protocol included precontrast, arterial, and portal phase scans. VNC images and iodine maps were created from 80 to 140 kVp images during the arterial and portal phases. VNC images were then compared with true, noncontrast (TNC) images, and iodine maps were compared with linearly blended images, both qualitatively and quantitatively. For the former comparison, image quality and acceptability of the VNC images as a replacement for TNC images were both rated. The CT numbers of the hepatic parenchyma, ablation zone, and image noise were measured. For the latter comparison, lesion conspicuity of the ablation zone and the additional benefit of integrating the iodine map into the routine protocol, were assessed. Contrast-to-noise ratios (CNR) of the ablation zone-to-liver and aorta-to-liver as well as the CT number differences between the center and the periphery of the ablation zone were calculated. The image quality of the VNC images was rated as good (mean grading score, 1.88) and the level of acceptance was 90% (68/75). The mean CT numbers of the hepatic parenchyma and ablation zone did not differ significantly between the TNC and the VNC images (P > 0.05). The lesion conspicuity of the ablation zone was rated as excellent or good in 97% of the iodine map (73/75), and the additional benefits of the iodine maps were positively rated as better to the same (mean 1.5). The CNR of the aorta-to-liver parenchyma was significantly higher on the iodine map (P = 0.002), and the CT number differences between the center and the periphery of the ablation zone were significantly lower on the iodine map (P VNC images can be an alternative to TNC

  16. Incidental Findings in Abdominal Dual-Energy Computed Tomography: Correlation Between True Noncontrast and Virtual Noncontrast Images Considering Renal and Liver Cysts and Adrenal Masses.

    Science.gov (United States)

    Slebocki, Karin; Kraus, Bastian; Chang, De-Hua; Hellmich, Martin; Maintz, David; Bangard, Christopher

    To assess correlation between attenuation measurements of incidental findings in abdominal second generation dual-energy computed tomography (CT) on true noncontrast (TNC) and virtual noncontrast (VNC) images. Sixty-three patients underwent arterial dual-energy CT (Somatom Definition Flash, Siemens; pitch factor, 0.75-1.0; gantry rotation time, 0.28 seconds) after endovascular aneurysm repair, consisting of a TNC single energy CT scan (collimation, 128 × 0.6 mm; 120 kVp) and a dual-energy arterial phase scan (collimation, 32 × 0.6 mm, 140 and 100 kVp; blended, 120 kVp data set). Attenuation measurements in Hounsfield units (HU) of liver parenchyma and incidental findings like renal and hepatic cysts and adrenal masses on TNC and VNC images were done by drawing regions of interest. Statistical analysis was performed by paired t test and Pearson correlation. Incidental findings were detected in 56 (89%) patients. There was excellent correlation for both renal (n = 40) and hepatic cysts (n = 12) as well as adrenal masses (n = 6) with a Pearson correlation of 0.896, 0.800, and 0.945, respectively, and mean attenuation values on TNC and VNC images of 10.6 HU ± 12.8 versus 5.1 HU ± 17.5 (attenuation value range from -8.8 to 59.1 HU vs -11.8 to 73.4 HU), 6.4 HU ± 5.8 versus 6.3 HU ± 4.6 (attenuation value range from 2.0 to 16.2 HU vs -3.0 to 15.9 HU), and 12.8 HU ± 11.2 versus 12.4 HU ± 10.2 (attenuation value range from -2.3 to 27.5 HU vs -2.2 to 23.6 HU), respectively. As proof of principle, liver parenchyma measurements also showed excellent correlation between TNC and VNC (n = 40) images with a Pearson correlation of 0.839 and mean attenuation values on TNC and VNC images of 47.2 HU ± 10.5 versus 43.8 HU ± 8.7 (attenuation value range from 21.9 to 60.2 HU vs 4.5 to 65.3 HU). In conclusion, attenuation measurements of incidental findings like renal cysts or adrenal masses on TNC and VNC images derived from second generation dual-energy CT scans show excellent

  17. [Comparison of diagnostic quality in hysterosalpingography between iodinated non-ionic contrast media with low and high osmolarity].

    Science.gov (United States)

    Piccotti, K; Guida, D; Carbonetti, F; Stefanetti, L; Macioce, A; Cremona, A; David, V

    Comparison of diagnostic quality in hysterosalpingography between low and high-osmolality contrast media. We performed a retrospective evaluation of two cohorts of patients who underwent HSG using contrast media with different osmolarity: the first group ,47 patients, underwent hysterosalpingography in the period September 2011-December 2012 using Iopromide 370 mg/ml; the second group, 50 patients, underwent HSG from January 2013 to October 2013 using Iomeprol 400 mg/ml. Three radiologists, in consensus reading,, reviewed the radiographs by assessing the following four parameters: opacification of the uterine cavity, uterine profiles definition, Fallopian tubes visualization, contrast media spillage into peritoneum. A score-scale from 0 to 3 was assigned for each of the mentioned parameter (0 = minimum non-diagnostic exam, 1 = sufficient examination; 2 = good quality examination; maximum 3 = high quality images). We documented a statistically significant higher quality in displaying Fallopian tubes among patients studied through high osmolarity contrast medium (Iopromide 370 mg/ml) than what obtained through lower osmolarity contrast medium (Iomeprol 400 mg/ml). The use of high osmolarity contrast medium enabled better visualization of the tubes and a greater number of diagnoses of chronic aspecific salpigintis due to the increased osmolality and viscosity of Iomeprol 400 mg/ml. There were no significant differences between the two contrast agents in the evaluation of intra-uterine pathology and in the evaluation of the tubal patency.

  18. Comparisons of Hysterosalpingography and Laparoscopy Results in the Diagnosis of Tubal Occlusion

    Directory of Open Access Journals (Sweden)

    Rafet Duraker

    2011-03-01

    Full Text Available Objective: The compliance rate between the hysterosalpingography (HSG and laparoscopy (L/S results in patients who diagnosed tubal occlusion on the HSG was investigated. Also, the incidence of endometriosis was evaluated in the study population. Material and Methods: Medical records of 139 women who were underwent L/S for the investigation of the tubal occlusion were reviewed retrospectively. The concordance rate between the HSG and L/S was investigated. The incidence of endometriosis in patients with no tubal pathology was compared with patients with unilaterally and bilaterally tubal occlusion. Results: Mean age of the women was 31.8±5.7years, mean BMI was measured as 24.6±4.6 kg/m2, and gravida 0 (0-5, mean infertility period was 30.7±3.7 months. Tubal occlusion was confirmed after the L/S in 38.8% of the patients (n=38 who has unilaterally tubal occlusion on the HSG. However, 58.8% (n=20 of the patients who were diagnosed as bilaterally tubal occlusion on the HSG was confirmed with the L/S. The misdiagnosis rate of the HSG was significantly high in women with unilaterally tubal occlusions compared with bilaterally tubal occlusions [(respectively, 61.2%, 51.2% (p: 0.001]. Endometriosis was observed in 28.4% of the patients who had patent tubes and in 13.9% of the patients in the unilaterally tubal occlusion group and and in 22.7% of the patients in the bilaterally tubal occlusion group. But the difference was not statistically significant when groups were compared according to the rate of endometriosis (p=0.24. Conclusion: HSG is the first step diagnostic test for the assessment of the fallopian tubes. Although L/S is more invasive technique than HSG, L/S with chromopertubation is the gold standard test for identifying periadnexal adhesive disease and endometriosis.

  19. Comparison of hysterosalpingography and laparoscopy in the evaluation of infertile women

    International Nuclear Information System (INIS)

    Sakar, Mehmet N.; Atay, Ahmet E.; Gul, T.; Celik, Y.

    2008-01-01

    Objective was to compare tuboperitoneal factors of infertile women hysterosalpingography (HSG) and laparoscopy. In this cohort study, 82 infertile cases were evaluated retrospectively by laparoscopy, 3 months subsequent to HSG in the Department of Gynecology and Obstetrics, Medical School of Dicle University, Diyarbakir, Turkey between March 2004 and April 2006. The findings of HSG and laparoscopy were compared. Out of 82 infertile women, pathological findings were observed in 45.1% by HSG and 54.9% had no pathological findings. On laparoscopic evaluation, however, pathological findings were observed in 65.85% and 34.15% had no pathological findings. The pathological findings were detected by laparoscopy in 20 of the 45(44.4%) patients who had had no pathological findings by HSG and no pathological findings were detected by laparoscopy in 3 of the 37 (8.1%) patients who had pathological findings by HSG. Laparoscopy revealed no pathological findings in 6 of 35 patients who had tubal pathology by HSG. The sensitivity of HSG was 63%, specificity was 89.3% and positive predictive value was 92% with a 55% predictive value and the accuracy ratio was 72%. Laparoscopy is a superior method for the result of tubal and pelvic pathologies in the evaluation of infertility. However, HSG is a more economical and elementary method suitable for evaluation of endometrial and tubal pathologies and laparoscopy is an appropriate method for examining the external part of tubae, fimbriae, the relation of tuba and ovary, endometriosis, adhesions, tuberculosis and other pathologies. Therefore, these 2 methods are not alternative but complementary. (author)

  20. Virtually teaching virtual leadership

    DEFF Research Database (Denmark)

    Henriksen, Thomas Duus; Nielsen, Rikke Kristine; Børgesen, Kenneth

    2017-01-01

    This paper seeks to investigate the challenges to virtual collaboration and leadership on basis of findings from a virtual course on collaboration and leadership. The course used for this experiment was designed as a practical approach, which allowed participants to experience curriculum phenomena....... This experimental course provided insights into the challenges involved in virtual processes, and those experiences where used for addressing the challenges that virtual leadership is confronted with. Emphasis was placed on the reduction of undesired virtual distance and its consequences through affinity building....... We found that student scepticism appeared when a breakdown resulted in increasing virtual distance, and raises questions on how leaders might translate or upgrade their understandings of leadership to handling such increased distance through affinity building....

  1. Advanced virtual monochromatic reconstruction of dual-energy unenhanced brain computed tomography in children: comparison of image quality against standard mono-energetic images and conventional polychromatic computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Juil [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Choi, Young Hun [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Cheon, Jung-Eun; Kim, Woo Sun; Kim, In-One [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Pak, Seong Yong [Siemens Healthineers, Seoul (Korea, Republic of); Krauss, Bernhard [Siemens Healthineers, Forchheim (Germany)

    2017-11-15

    Advanced virtual monochromatic reconstruction from dual-energy brain CT has not been evaluated in children. To determine the most effective advanced virtual monochromatic imaging energy level for maximizing pediatric brain parenchymal image quality in dual-energy unenhanced brain CT and to compare this technique with conventional monochromatic reconstruction and polychromatic scanning. Using both conventional (Mono) and advanced monochromatic reconstruction (Mono+) techniques, we retrospectively reconstructed 13 virtual monochromatic imaging energy levels from 40 keV to 100 keV in 5-keV increments from dual-source, dual-energy unenhanced brain CT scans obtained in 23 children. We analyzed gray and white matter noise ratios, signal-to-noise ratios and contrast-to-noise ratio, and posterior fossa artifact. We chose the optimal mono-energetic levels and compared them with conventional CT. For Mono+maximum optima were observed at 60 keV, and minimum posterior fossa artifact at 70 keV. For Mono, optima were at 65-70 keV, with minimum posterior fossa artifact at 75 keV. Mono+ was superior to Mono and to polychromatic CT for image-quality measures. Subjective analysis rated Mono+superior to other image sets. Optimal virtual monochromatic imaging using Mono+ algorithm demonstrated better image quality for gray-white matter differentiation and reduction of the artifact in the posterior fossa. (orig.)

  2. Feasibility of dynamic MR-hysterosalpingography for the diagnostic work-up of infertile women

    International Nuclear Information System (INIS)

    Winter, Leopold; Gluecker, Thomas; Steinbrich, Wolfgang; Pegios, Wassilios; Steimann, Sabine; De Geyter, Christian; Froehlich, Johannes M.

    2010-01-01

    Background: Tubal disturbances often contribute to infertility. Conventional hysterosalpingography (HSG) is considered as standard in the assessment of the patency of the fallopian tubes, but requires ionizing radiation and is restricted to the imaging of endoluminal structures. Purpose: To evaluate dynamic magnetic resonance-HSG (dMR-HSG) in the diagnostic work-up in patients with infertility. Material and Methods: Thirty-seven consecutive infertile women underwent dMR-HSG: 20 ml of gadolinium-polyvidone solution (18.4 mM Dotarem 1:20 with polyvidone) were injected intracervically through a 5-Charriere balloon catheter while acquiring five consecutive flash-3D T1-weighted MR sequences with fat saturation. Two experienced readers assessed image quality and anatomic-pathologic correlations prospectively. The relevance of results was evaluated in the clinical context of each patient. Patient comfort was evaluated with a standardized questionnaire. Results: dMR-HSG was successfully completed in 33/37 patient with an average study time of 45 min. In 4 of 37 patients the catheter became dislodged during the examination, resulting in two complete diagnostic failures. Failure in another two patients was due to preliminary termination because of excessive pain and discomfort during the application of the contrast solution. The uterine cavity was completely visualized and bilateral fallopian tube patency was confirmed by dMR-HSG in 27 of 33 patients. Bilateral tubal occlusion was diagnosed in one of the remaining six patients and was confirmed by laparoscopy. Successful selective tubal catheterization was performed in one additional patient with unilateral and one patient with bilateral fallopian tube occlusion. In three cases, the catheter became dislocated at the end of the examination without demonstration of tubal patency. Since all three patients refused diagnostic laparoscopy and conventional HSG, possible bilateral occlusions of the fallopian tubes could not be

  3. Paracetamol as a prophylactic analgesic for hysterosalpingography: A double blind randomized controlled trial

    International Nuclear Information System (INIS)

    Elson, E.M.; Ridley, N.T.F.

    2000-01-01

    AIM: To evaluate the effectiveness of paracetamol as a prophylactic analgesic for hysterosalpingography (HSG). DESIGN: A prospective double blind randomized controlled trial comparing one 1 g of paracetamol (SmithKline Beecham, Brentford, U.K.) to placebo taken 30 min before HSG. One hundred consecutive out-patients were studied prospectively. The analgesic effectiveness during the procedure and at 24 h and 1 week post procedure was analysed by a postal pain score questionnaire. Additional data on the ethnicity of the patient, sex and level of experience of the radiologist performing the hysterosalpingogram, the parity of the patient, the ease of the procedure, and whether pathology was identified were also recorded. RESULTS: Eighty-eight patients (88%) replied, 39 (44%) received paracetamol and 49 placebo (56%). During the procedure 3/39 (7%) of women in the paracetamol group were pain-free compared to 9/49 (18%) in the placebo group, which was not significant (P = 0.11). At 24 h, 15/39 (38%) of women in the paracetamol group were pain-free compared to 20/49 (41%) in the placebo group, which was not significant (P = 0.82). At 1 week, 27/39 (69%) of women in the paracetamol group were pain-free compared to 29/49 (59%) in the placebo group, which was not significant (P = 0.33). No significant difference in mean pain scores was determined during the procedure (P 0.91), or at 24 h post procedure (P = 0.94). Similarly, no difference in mean pain scores was identified with regard to the ethnicity of the patient, the sex of the radiologist performing the procedure, the level of experience of the radiologist performing the procedure, or whether pathology was present or not. Difficult cannulations were associated with higher mean pain scores, however, there was no difference in mean pain scores between the paracetamol or placebo groups for both easy and difficult cannulations. CONCLUSION: Paracetamol is not effective as a prophylactic analgesic for HSG. If a prophylactic

  4. Paracetamol as a prophylactic analgesic for hysterosalpingography: A double blind randomized controlled trial

    Energy Technology Data Exchange (ETDEWEB)

    Elson, E.M.; Ridley, N.T.F

    2000-09-01

    AIM: To evaluate the effectiveness of paracetamol as a prophylactic analgesic for hysterosalpingography (HSG). DESIGN: A prospective double blind randomized controlled trial comparing one 1 g of paracetamol (SmithKline Beecham, Brentford, U.K.) to placebo taken 30 min before HSG. One hundred consecutive out-patients were studied prospectively. The analgesic effectiveness during the procedure and at 24 h and 1 week post procedure was analysed by a postal pain score questionnaire. Additional data on the ethnicity of the patient, sex and level of experience of the radiologist performing the hysterosalpingogram, the parity of the patient, the ease of the procedure, and whether pathology was identified were also recorded. RESULTS: Eighty-eight patients (88%) replied, 39 (44%) received paracetamol and 49 placebo (56%). During the procedure 3/39 (7%) of women in the paracetamol group were pain-free compared to 9/49 (18%) in the placebo group, which was not significant (P = 0.11). At 24 h, 15/39 (38%) of women in the paracetamol group were pain-free compared to 20/49 (41%) in the placebo group, which was not significant (P = 0.82). At 1 week, 27/39 (69%) of women in the paracetamol group were pain-free compared to 29/49 (59%) in the placebo group, which was not significant (P = 0.33). No significant difference in mean pain scores was determined during the procedure (P 0.91), or at 24 h post procedure (P = 0.94). Similarly, no difference in mean pain scores was identified with regard to the ethnicity of the patient, the sex of the radiologist performing the procedure, the level of experience of the radiologist performing the procedure, or whether pathology was present or not. Difficult cannulations were associated with higher mean pain scores, however, there was no difference in mean pain scores between the paracetamol or placebo groups for both easy and difficult cannulations. CONCLUSION: Paracetamol is not effective as a prophylactic analgesic for HSG. If a prophylactic

  5. Feasibility of dynamic MR-hysterosalpingography for the diagnostic work-up of infertile women

    Energy Technology Data Exchange (ETDEWEB)

    Winter, Leopold; Gluecker, Thomas; Steinbrich, Wolfgang; Pegios, Wassilios (Dept. of Radiology, Univ. Hospital Basel (Switzerland)), e-mail: winterl@uhbs.ch; Steimann, Sabine; De Geyter, Christian (Women' s Hospital, Univ. Hospital Basel (Switzerland)); Froehlich, Johannes M. (Guerbet AG, Zuerich (Switzerland))

    2010-07-15

    Background: Tubal disturbances often contribute to infertility. Conventional hysterosalpingography (HSG) is considered as standard in the assessment of the patency of the fallopian tubes, but requires ionizing radiation and is restricted to the imaging of endoluminal structures. Purpose: To evaluate dynamic magnetic resonance-HSG (dMR-HSG) in the diagnostic work-up in patients with infertility. Material and Methods: Thirty-seven consecutive infertile women underwent dMR-HSG: 20 ml of gadolinium-polyvidone solution (18.4 mM Dotarem 1:20 with polyvidone) were injected intracervically through a 5-Charriere balloon catheter while acquiring five consecutive flash-3D T1-weighted MR sequences with fat saturation. Two experienced readers assessed image quality and anatomic-pathologic correlations prospectively. The relevance of results was evaluated in the clinical context of each patient. Patient comfort was evaluated with a standardized questionnaire. Results: dMR-HSG was successfully completed in 33/37 patient with an average study time of 45 min. In 4 of 37 patients the catheter became dislodged during the examination, resulting in two complete diagnostic failures. Failure in another two patients was due to preliminary termination because of excessive pain and discomfort during the application of the contrast solution. The uterine cavity was completely visualized and bilateral fallopian tube patency was confirmed by dMR-HSG in 27 of 33 patients. Bilateral tubal occlusion was diagnosed in one of the remaining six patients and was confirmed by laparoscopy. Successful selective tubal catheterization was performed in one additional patient with unilateral and one patient with bilateral fallopian tube occlusion. In three cases, the catheter became dislocated at the end of the examination without demonstration of tubal patency. Since all three patients refused diagnostic laparoscopy and conventional HSG, possible bilateral occlusions of the fallopian tubes could not be

  6. Clinical application of hysterosalpingography with a double-lumen catheter of a contrast media combination consisting iohexol and saline

    International Nuclear Information System (INIS)

    Xi Jiayuan; Jiang Yong; Cao Xinhua; Zhu Ying; Lv Liang; Zhao Xinxiang; Wei Dingying; Shao Jingxuan; Hua Jian

    2005-01-01

    Objective: To evaluate the clinical value of hysteosalpingographic diagnosis in infertile women. Methods: After a catheter with a double-lumen saccule was inserted into the uterine cavity, saline or air of 2.5-3.5 ml was injected to fill the saccule. The filled saccule was inserted at the isthmus of uterus for blocking the internal orifice. The contrast medium was injected through the catheter into the uterine cavity and fallopian tubes to undertake hysterosalpingography and fallopian tube reopening. In case of fallopian tube obstruction, the injection pressure could be increased to obtain recanalization. All operations and selective imagings were carried out under TV supervision. Results: 2698 cases including 806 primary infertile women and 1868 secondary infertile women were examined by this method. Technical success rate was 99.5% with 2198 cases (81.9%) having normal uterus, 249 (9.3%) congenital abnormal uterus and 238 (8.9%) uterus diseases. The number of obstructed fallopian tube was 3028 with 117 serious hydropsy (3.8%). Ninety-eight cases had been examined with lipiodol hysterosalpingography in other hospitals with 35 cases still having lipiodol accumulated within the uterine cavities and fallopian tubes. No serious complications or death occurred except slight pain. Conclusions: Double-lumen cather with a contrast media combination of iohexol and saline for hysterosal pinography is safe, easy and effective, outcoming with excellent quality images. More information can be gained with this method than traditional lipiodol hyterosalpinography, and furthermore could have compression during radiogrophy and avoid the long term stasis of lipiodol. (authors)

  7. Virtual colonoscopy

    Science.gov (United States)

    Colonoscopy - virtual; CT colonography; Computed tomographic colonography; Colography - virtual ... Differences between virtual and conventional colonoscopy include: VC can view the colon from many different angles. This is not as easy ...

  8. Virtual Monoenergetic Images From a Novel Dual-Layer Spectral Detector Computed Tomography Scanner in Portal Venous Phase: Adjusted Window Settings Depending on Assessment Focus Are Essential for Image Interpretation.

    Science.gov (United States)

    Hickethier, Tilman; Iuga, Andra-Iza; Lennartz, Simon; Hauger, Myriam; Byrtus, Jonathan; Luetkens, Julian A; Haneder, Stefan; Maintz, David; Doerner, Jonas

    We aimed to determine optimal window settings for conventional polyenergetic (PolyE) and virtual monoenergetic images (MonoE) derived from abdominal portal venous phase computed tomography (CT) examinations on a novel dual-layer spectral-detector CT (SDCT). From 50 patients, SDCT data sets MonoE at 40 kiloelectron volt as well as PolyE were reconstructed and best individual window width and level values manually were assessed separately for evaluation of abdominal arteries as well as for liver lesions. Via regression analysis, optimized individual values were mathematically calculated. Subjective image quality parameters, vessel, and liver lesion diameters were measured to determine influences of different W/L settings. Attenuation and contrast-to-noise values were significantly higher in MonoE compared with PolyE. Compared with standard settings, almost all adjusted W/L settings varied significantly and yielded higher subjective scoring. No differences were found between manually adjusted and mathematically calculated W/L settings. PolyE and MonoE from abdominal portal venous phase SDCT examinations require appropriate W/L settings depending on reconstruction technique and assessment focus.

  9. On-line course as tools for radiation protection training in patients. A practical case in computerized tomography; El Aula Virtual como herramienta para la formacion en PR del paciente; caso practico en tomografia computarizada

    Energy Technology Data Exchange (ETDEWEB)

    Medina Campos, J.; Fernandez Tallon, J.; Busca Suau, J.; Baro Casanovas, J.

    2006-07-01

    The rise in ionizing radiation applications within the field of diagnostics, with the corresponding increase in both number and doses received by patients, requires adequate resources for education and training in radiological protection. In is quite difficult to assemble professionals at a specific place to carry out training. However, the use of Information and Communication Technologies (IT) makes it possible to carry out training. However, the use of Information and Communication Technologies (IT) makes it possible to carry out training through Internet in an effective, easy and amusing way (e-learning). An on-line course of patient radiological protection and quality control in computer tomography has been developed aimed at professionals that use these diagnostic techniques. The course has been run twice in the period 2005-2006. The course is found on an Internet-accessible Virtual Campus, which allows access to multimedia contents, communication between students and instructors and follow-up of students performance. Final evaluation is done on-line and successfully passing the course counts for 8.9 credits in the Continuous Education Programme of Spanish Health Systems. (Author)

  10. Intra-stent tissue evaluation within bare metal and drug-eluting stents > 3 years since implantation in patients with mild to moderate neointimal proliferation using optical coherence tomography and virtual histology intravascular ultrasound.

    Science.gov (United States)

    Kitabata, Hironori; Loh, Joshua P; Pendyala, Lakshmana K; Omar, Alfazir; Ota, Hideaki; Minha, Sa'ar; Magalhaes, Marco A; Torguson, Rebecca; Chen, Fang; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2014-04-01

    We aimed to compare neointimal tissue characteristics between bare-metal stents (BMS) and drug-eluting stents (DES) at long-term follow-up using optical coherence tomography (OCT) and virtual histology intravascular ultrasound (VH-IVUS). Neoatherosclerosis in neointima has been reported in BMS and in DES. Thirty patients with 36 stented lesions [BMS (n=17) or DES (n=19)] >3years after implantation were prospectively enrolled. OCT and VH-IVUS were performed and analyzed independently. Stents with ≥70% diameter stenosis were excluded. The median duration from implantation was 126.0months in the BMS group and 60.0months in the DES group (p 3years to stents had evidence of intimal disruption. The percentage volume of necrotic core (16.1% [9.7, 20.3] vs. 9.7% [7.0, 16.5], p=0.062) and dense calcium (9.5% [3.8, 13.6] vs. 2.7% [0.4, 4.9], p=0.080) in neointima tended to be greater in BMS-treated lesions. Intra-stent VH-TCFA (BMS vs. DES 45.5% vs. 18.2%, p=0.361) did not differ significantly. At long-term follow-up beyond 3 years after implantation, the intra-stent neointimal tissue characteristics appeared similar for both BMS and DES. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Virtual Reality

    Science.gov (United States)

    1993-04-01

    until exhausted. SECURITY CLASSIFICATION OF THIS PAGE All other editions are obsolete. UNCLASSIFIED " VIRTUAL REALITY JAMES F. DAILEY, LIEUTENANT COLONEL...US" This paper reviews the exciting field of virtual reality . The author describes the basic concepts of virtual reality and finds that its numerous...potential benefits to society could revolutionize everyday life. The various components that make up a virtual reality system are described in detail

  12. Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography

    International Nuclear Information System (INIS)

    D'Angelo, Tommaso; ''G. Martino'' University Hospital, Messina; Bucher, Andreas M.; Lenga, Lukas; Arendt, Christophe T.; Peterke, Julia L.; Martin, Simon S.; Leithner, Doris; Vogl, Thomas J.; Wichmann, Julian L.; Caruso, Damiano; University Hospital, Latina; Mazziotti, Silvio; Blandino, Alfredo; Ascenti, Giorgio; University Hospital, Messina; Othman, Ahmed E.

    2018-01-01

    To define optimal window settings for displaying virtual monoenergetic images (VMI) of dual-energy CT pulmonary angiography (DE-CTPA). Forty-five patients who underwent clinically-indicated third-generation dual-source DE-CTPA were retrospectively evaluated. Standard linearly-blended (M 0 .6), 70-keV traditional VMI (M70), and 40-keV noise-optimised VMI (M40+) reconstructions were analysed. For M70 and M40+ datasets, the subjectively best window setting (width and level, B-W/L) was independently determined by two observers and subsequently related with pulmonary artery attenuation to calculate separate optimised values (O-W/L) using linear regression. Subjective evaluation of image quality (IQ) between W/L settings were assessed by two additional readers. Repeated measures of variance were performed to compare W/L settings and IQ indices between M 0 .6, M70, and M40+. B-W/L and O-W/L for M70 were 460/140 and 450/140, and were 1100/380 and 1070/380 for M40+, respectively, differing from standard DE-CTPA W/L settings (450/100). Highest subjective scores were observed for M40+ regarding vascular contrast, embolism demarcation, and overall IQ (all p<0.001). Application of O-W/L settings is beneficial to optimise subjective IQ of VMI reconstructions of DE-CTPA. A width slightly less than two times the pulmonary trunk attenuation and a level approximately of overall pulmonary vessel attenuation are recommended. (orig.)

  13. Virtual Box

    DEFF Research Database (Denmark)

    Davis, Hilary; Skov, Mikael B.; Stougaard, Malthe

    2007-01-01

    . This paper reports on the design, implementation and initial evaluation of Virtual Box. Virtual Box attempts to create a physical and engaging context in order to support reciprocal interactions with expressive content. An implemented version of Virtual Box is evaluated in a location-aware environment...

  14. Wireless virtualization

    CERN Document Server

    Wen, Heming; Le-Ngoc, Tho

    2013-01-01

    This SpringerBriefs is an overview of the emerging field of wireless access and mobile network virtualization. It provides a clear and relevant picture of the current virtualization trends in wireless technologies by summarizing and comparing different architectures, techniques and technologies applicable to a future virtualized wireless network infrastructure. The readers are exposed to a short walkthrough of the future Internet initiative and network virtualization technologies in order to understand the potential role of wireless virtualization in the broader context of next-generation ubiq

  15. Virtual marketing in virtual enterprises

    OpenAIRE

    Ale Ebrahim, Nader; Fattahi, Hamaid Ali; Golnam, Arash

    2008-01-01

    Virtualization caused tremendous evolution in the economics of marketing channels, patterns of physical distribution and the structure of distributors and developed a new concept that is known as virtual marketing (VM). VM combines the powerful technologies of interactive marketing and virtual reality. Virtual enterprise (VE) refers to an organization not having a clear physical locus. In other words, VE is an organization distributed geographically and whose work is coordinated through e...

  16. Estimate of worker and patient exposures and quality control in hysterosalpingography exams; Estimativa da exposicao de pacientes e trabalhadores e controle de qualidade em exames de histerossalpingografia

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Barbara Beatriz Dias

    2006-06-15

    Hysterosalpingography (HSG) is a relatively frequent radiological procedure, which is used to access and study the uterine cavity and the tubary permeability. The estimate of the radiation doses received by the patients, and of the associated risks, has become of great interest in recent years. The importance in evaluating the received doses becomes even higher when the gonads region is irradiated; as in the case of hysterosalpingography, where the patients are relatively young, existing a high probability of future pregnancy. In HSG procedure the physician stays beside the patient, being also exposed. The purpose of this study was to analyze, during HSG procedures, the exposition of patients, measuring the kerma-area (P{sub K,A}) product by using an ionization chamber of big area, to evaluate the doses received by the radiologist using thermoluminescent dosemeters and to evaluate the quality of image by means of qualitative methods. The results gotten during the accompaniment of 86 examinations had been the following ones: the average P{sub K,A} was 706 {+-} 388 cGy.cm{sup 2}, to an average exposition time of 2 {+-} 1 minutes. In order to optimize the exposure of patients and workers, the time of scopy and the number of images should be reduced, whenever it is possible. Due to the significant values of equivalent dose received by the lens, the use of plumbiferous eyeglasses is recommended. (author)

  17. Virtual Exploratories

    DEFF Research Database (Denmark)

    Jensen, Sisse Siggaard

    2006-01-01

    -systems, the paper introduces the designing strategy referred to as virtual exploratories. Some of the advanced virtual worlds may inspire the design of such provoking and challenging virtual exploratories, and especially the Massively Multi-User Online Role-Playing Games (MMORPGS). However, if we have to learn from...... the design and activity of the advanced virtual worlds and role-playing games, then the empirical research on the actors’ activity, while they are acting, is an important precondition to it. A step towards the conception of such a designing strategy for virtual exploratories is currently pursued....... [1] The research project: Actors and Avatars Communicating in Virtual Worlds – an Empirical Analysis of Actors’ Sense-making Strategies When Based on a Communication Theoretical Approach’ (2006-2007) is supported...

  18. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography; Avaliacao de dose em procedimentos especiais de fluoroscopia: histerossalpingografia e dacriocistografia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Cintya Carolina Barbosa

    2006-04-15

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  19. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography; Avaliacao de dose em procedimentos especiais de fluoroscopia: histerossalpingografia e dacriocistografia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Cintya Carolina Barbosa

    2006-04-15

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  20. Virtual Reflexes

    OpenAIRE

    Jonker, Catholijn; Broekens, Joost; Plaat, Aske

    2014-01-01

    Virtual Reality is used successfully to treat people for regular phobias. A new challenge is to develop Virtual Reality Exposure Training for social skills. Virtual actors in such systems have to show appropriate social behavior including emotions, gaze, and keeping distance. The behavior must be realistic and real-time. Current approaches consist of four steps: 1) trainee social signal detection, 2) cognitive-affective interpretation, 3) determination of the appropriate bodily responses, and...

  1. Virtual volatility

    Science.gov (United States)

    Silva, A. Christian; Prange, Richard E.

    2007-03-01

    We introduce the concept of virtual volatility. This simple but new measure shows how to quantify the uncertainty in the forecast of the drift component of a random walk. The virtual volatility also is a useful tool in understanding the stochastic process for a given portfolio. In particular, and as an example, we were able to identify mean reversion effect in our portfolio. Finally, we briefly discuss the potential practical effect of the virtual volatility on an investor asset allocation strategy.

  2. Virtual bronchoscopy

    International Nuclear Information System (INIS)

    Rogalla, P.; Meiri, N.; Hamm, B.; Rueckert, J.C.; Schmidt, B.; Witt, C.

    2001-01-01

    Flexible bronchoscopy represents a clinically well-established invasive diagnostic tool. Virtual bronchoscopies, calculated from thin-slice CT sections, allow astonishing immitations of reality although principal differences exist between both technologies: the Fact that colour representation is artificial and concommitant interventions are impossible limits the clinical use of virtual bronchoscopy. However, its value increases when calculations can be attained within minutes due to technological advancements, and when virtually any chest CT is suitable for further postprocessing. Indications, findings and the clinical role of virtual bronchoscopy are discussed. (orig.) [de

  3. Virtual projects

    DEFF Research Database (Denmark)

    Svejvig, Per; Commisso, Trine Hald

    2012-01-01

    that the best practice knowledge has not permeated sufficiently to the practice. Furthermore, the appropriate application of information and communication technology (ICT) remains a big challenge, and finally project managers are not sufficiently trained in organizing and conducting virtual projects....... The overall implications for research and practice are to acknowledge virtual project management as very different to traditional project management and to address this difference.......Virtual projects are common with global competition, market development, and not least the financial crisis forcing organizations to reduce their costs drastically. Organizations therefore have to place high importance on ways to carry out virtual projects and consider appropriate practices...

  4. Virtual Workshop

    DEFF Research Database (Denmark)

    Buus, Lillian; Bygholm, Ann

    In relation to the Tutor course in the Mediterranean Virtual University (MVU) project, a virtual workshop “Getting experiences with different synchronous communication media, collaboration, and group work” was held with all partner institutions in January 2006. More than 25 key-tutors within MVU...

  5. Computerized tomography

    International Nuclear Information System (INIS)

    Rubashov, I.B.

    1985-01-01

    Operating principle is described for the devices of computerized tomography used in medicine for diagnosis of brain diseases. Computerized tomography is considered as a part of computerized diagnosis, as a part of information science. It is shown that computerized tomography is a real existed field of investigations in medicine and industrial production

  6. Occupational Radiation Exposure to the Extremities of Medical Staff during Hysterosalpingography and Radionuclide Bone Scan Procedures in Several Nigerian Hospitals

    Directory of Open Access Journals (Sweden)

    Nnamdi Norbert Jibiri

    2016-10-01

    Full Text Available Objective: The practice of regular dose measurement helps to ascertain the level of occupational dose delivered to the staff involved in diagnostic procedures. This study was carried out to evaluate the dose exposed to the hands of radiologists and a radiologic technologist carrying out HSG and radionuclide bone scan examinations in several hospitals in Nigeria. Methods: Radiation doses exposed to the hands of radiologists and a technician carrying out hysterosalpingography (HSG and bone scan procedures were measured using calibrated thermo-luminescent dosimeters. Five radiologists and a radiologic technologist were included in the study for dose measurement. Results: The study indicates that each radiologist carried out approximately 2 examinations per week with the mean dose ranging between 0.49-0.62 mSv per week, resulting in an annual dose of 191 mSv. Similarly, the occupational dose delivered to both the left and right hands of a radiologic technologist administering 99mTc-methylene diphosphonate (MDP without cannula and with cannula were 10.68 (720.2 and 13.82 (556.4 mSv per week (and per annum, respectively. It was determined that the left hand of the personnel received higher doses than their right hand. Conclusion: The estimated annual dose during HSG is far below the annual dose limit for deterministic effects, however, it is greater than 10% of the applicable annual dose limit. Hence, routine monitoring is required to ensure adequate protection of the personnel. The total annual dose received during the bone scan exceeds the annual dose limit for both hands, and the dose to either left or right hand is greater than the dose limit of 500 mSv/yr. The radiologists monitored are not expected to incur any deterministic effects during HSG examinations, however, accumulated doses arising from the scattered radiation to the eyes, legs, and neck could be substantial and might lead to certain effects. More staff are required to administer 99m

  7. Monte Carlo based estimation of organ and effective doses to patients undergoing hysterosalpingography and retrograde urethrography fluoroscopy procedures

    Science.gov (United States)

    Ngaile, J. E.; Msaki, P. K.; Kazema, R. R.

    2018-04-01

    Contrast investigations of hysterosalpingography (HSG) and retrograde urethrography (RUG) fluoroscopy procedures remain the dominant diagnostic tools for the investigation of infertility in females and urethral strictures in males, respectively, owing to the scarcity and high cost of services of alternative diagnostic technologies. In light of the radiological risks associated with contrast based investigations of the genitourinary tract systems, there is a need to assess the magnitude of radiation burden imparted to patients undergoing HSG and RUG fluoroscopy procedures in Tanzania. The air kerma area product (KAP), fluoroscopy time, number of images, organ dose and effective dose to patients undergoing HSG and RUG procedures were obtained from four hospitals. The KAP was measured using a flat transmission ionization chamber, while the organ and effective doses were estimated using the knowledge of the patient characteristics, patient related exposure parameters, geometry of examination, KAP and Monte Carlo calculations (PCXMC). The median values of KAP for the HSG and RUG were 2.2 Gy cm2 and 3.3 Gy cm2, respectively. The median organ doses in the present study for the ovaries, urinary bladder and uterus for the HSG procedures, were 1.0 mGy, 4.0 mGy and 1.6 mGy, respectively, while for urinary bladder and testes of the RUG were 3.4 mGy and 5.9 mGy, respectively. The median values of effective doses for the HSG and RUG procedures were 0.65 mSv and 0.59 mSv, respectively. The median values of effective dose per hospital for the HSG and RUG procedures had a range of 1.6-2.8 mSv and 1.9-5.6 mSv, respectively, while the overall differences between individual effective doses across the four hospitals varied by factors of up to 22.0 and 46.7, respectively for the HSG and RUG procedures. The proposed diagnostic reference levels (DRLs) for the HSG and RUG were for KAP 2.8 Gy cm2 and 3.9 Gy cm2, for fluoroscopy time 0.8 min and 0.9 min, and for number of images 5 and 4

  8. Virtual Teams.

    Science.gov (United States)

    Geber, Beverly

    1995-01-01

    Virtual work teams scattered around the globe are becoming a feature of corporate workplaces. Although most people prefer face-to-face meetings and interactions, reality often requires telecommuting. (JOW)

  9. Virtual data

    International Nuclear Information System (INIS)

    Bjorklund, E.

    1993-01-01

    In the 1970's, when computers were memory limited, operating system designers created the concept of ''virtual memory'' which gave users the ability to address more memory than physically existed. In the 1990s, many large control systems have the potential for becoming data limited. We propose that many of the principles behind virtual memory systems (working sets, locality, caching, and clustering) can also be applied to data-limited systems - creating, in effect, ''virtual data systems.'' At the Los Alamos National Laboratory's Clinton P. Anderson Meson Physics Facility (LAMPF), we have applied these principles to a moderately sized (10,000 data points) data acquisition and control system. To test the principles, we measured the system's performance during tune-up, production, and maintenance periods. In this paper, we present a general discussion of the principles of a virtual data system along with some discussion of our own implementation and the results of our performance measurements

  10. Virtual Worlds for Virtual Organizing

    Science.gov (United States)

    Rhoten, Diana; Lutters, Wayne

    The members and resources of a virtual organization are dispersed across time and space, yet they function as a coherent entity through the use of technologies, networks, and alliances. As virtual organizations proliferate and become increasingly important in society, many may exploit the technical architecture s of virtual worlds, which are the confluence of computer-mediated communication, telepresence, and virtual reality originally created for gaming. A brief socio-technical history describes their early origins and the waves of progress followed by stasis that brought us to the current period of renewed enthusiasm. Examination of contemporary examples demonstrates how three genres of virtual worlds have enabled new arenas for virtual organizing: developer-defined closed worlds, user-modifiable quasi-open worlds, and user-generated open worlds. Among expected future trends are an increase in collaboration born virtually rather than imported from existing organizations, a tension between high-fidelity recreations of the physical world and hyper-stylized imaginations of fantasy worlds, and the growth of specialized worlds optimized for particular sectors, companies, or cultures.

  11. Virtual Vision

    Science.gov (United States)

    Terzopoulos, Demetri; Qureshi, Faisal Z.

    Computer vision and sensor networks researchers are increasingly motivated to investigate complex multi-camera sensing and control issues that arise in the automatic visual surveillance of extensive, highly populated public spaces such as airports and train stations. However, they often encounter serious impediments to deploying and experimenting with large-scale physical camera networks in such real-world environments. We propose an alternative approach called "Virtual Vision", which facilitates this type of research through the virtual reality simulation of populated urban spaces, camera sensor networks, and computer vision on commodity computers. We demonstrate the usefulness of our approach by developing two highly automated surveillance systems comprising passive and active pan/tilt/zoom cameras that are deployed in a virtual train station environment populated by autonomous, lifelike virtual pedestrians. The easily reconfigurable virtual cameras distributed in this environment generate synthetic video feeds that emulate those acquired by real surveillance cameras monitoring public spaces. The novel multi-camera control strategies that we describe enable the cameras to collaborate in persistently observing pedestrians of interest and in acquiring close-up videos of pedestrians in designated areas.

  12. The value of virtual unenhanced computed tomography in the diagnosis of aortic disease%双能量CT虚拟平扫在主动脉疾病中的应用价值

    Institute of Scientific and Technical Information of China (English)

    姜亮; 殷信道; 王利伟; 王绍娟

    2015-01-01

    Objective To evaluate the probability of virtual non-contrast(VNC)images to replace real non-contrast (RNC)images in aortic diseases with dual-energy computed tomography(CT).Methods Dual-energy CT angiography were performed in a total of 5 1 patients with aortic diseases by dual-source CT,and VNC images were obtained through post-processing reconstruction.Image quality and radiation dosage of VNC and RNC groups were compared.Results CT value of ascending aorta and dorsal muscles,ves-sel noise and signal noise ratio of VNC images were higher than those of RNC.The quality score of VNC images(3.61±0.53)were lower than those of RNC images(3.78±0.42),but there was no significant difference between two groups.Radiation dose of aortic CT examination was decreased about 39.66% by applying VNC technology to replace RNC scan,there was significant difference be-tween two groups.The overall evaluation result is that about 90% (46/5 1)of VNC images can completely replace the RNC images. Conclusion The application of VNC technology significantly reduces radiation dose of the aortic CT examination;in most cases, VNC images can replace RNC images.%目的:评价双能量 CT 虚拟平扫(VNC)技术在主动脉 CT 检查中替代真实平扫(RNC)的可行性。方法应用双源 CT机对51例主动脉疾病患者进行双能量 CT 血管成像,利用后处理软件重建后得到 VNC 图像,比较 VNC 与 RNC 2组图像质量和辐射剂量。结果VNC 图像升主动脉及脊柱后方肌肉的 CT 值、血管噪声、信噪比(SNR)均高于 RNC 图像;图像质量评分(3.61±0.53)稍低于 RNC 图像(3.78±0.42),但两者差异无统计学意义。VNC 代替 RNC 图像后可使主动脉 CT 检查的有效辐射剂量减少约39.66%,两者差异有统计学意义。总体评价认为约90%(46/51)的 VNC 技术能完全取代 RNC 平扫。结论虚拟平扫技术的应用显著减少了主动脉 CT 检查的辐射剂量,大部分的 VNC 图像能够替代 RNC 图像。

  13. Virtual Sustainability

    Directory of Open Access Journals (Sweden)

    William Sims Bainbridge

    2010-09-01

    Full Text Available In four ways, massively multiplayer online role-playing games may serve as tools for advancing sustainability goals, and as laboratories for developing alternatives to current social arrangements that have implications for the natural environment. First, by moving conspicuous consumption and other usually costly status competitions into virtual environments, these virtual worlds might reduce the need for physical resources. Second, they provide training that could prepare individuals to be teleworkers, and develop or demonstrate methods for using information technology to replace much transportation technology, notably in commuting. Third, virtual worlds and online games build international cooperation, even blending national cultures, thereby inching us toward not only the world consciousness needed for international agreements about the environment, but also toward non-spatial government that cuts across archaic nationalisms. Finally, realizing the potential social benefits of this new technology may urge us to reconsider a number of traditional societal institutions.

  14. Virtual Tower

    International Nuclear Information System (INIS)

    Wayne, R.A.

    1997-01-01

    The primary responsibility of an intrusion detection system (IDS) operator is to monitor the system, assess alarms, and summon and coordinate the response team when a threat is acknowledged. The tools currently provided to the operator are somewhat limited: monitors must be switched, keystrokes must be entered to call up intrusion sensor data, and communication with the response force must be maintained. The Virtual tower is an operator interface assembled from low-cost commercial-off-the-shelf hardware and software; it enables large amounts of data to be displayed in a virtual manner that provides instant recognition for the operator and increases assessment accuracy in alarm annunciator and control systems. This is accomplished by correlating and fusing the data into a 360-degree visual representation that employs color, auxiliary attributes, video, and directional audio to prompt the operator. The Virtual Tower would be a valuable low-cost enhancement to existing systems

  15. Virtual care

    DEFF Research Database (Denmark)

    Kamp, Annette; Aaløkke Ballegaard, Stinne

    of retrenchment, promising better quality, empowerment of citizens and work that is smarter and more qualified. Through ethnographic field studies we study the introduction of virtual home care in Danish elderly care, focusing on the implications for relational work and care relations. Virtual home care entails...... the performance of specific home care services by means of video conversations rather than physical visits in the citizens’ homes. As scholars within the STS tradition maintain, technologies do not simply replace a human function; they rather transform care work, redistributing tasks between citizens, technology...... point out how issues of trust and surveillance, which are always negotiated in care relations, are in fact accentuated in this kind of virtual care work. Moreover, we stress that the contemporary institutional context, organization and time schedules have a vast impact on the practices developed....

  16. Virtual toolbox

    Science.gov (United States)

    Jacobus, Charles J.; Jacobus, Heidi N.; Mitchell, Brian T.; Riggs, A. J.; Taylor, Mark J.

    1993-04-01

    At least three of the five senses must be fully addressed in a successful virtual reality (VR) system. Sight, sound, and touch are the most critical elements for the creation of the illusion of presence. Since humans depend so much on sight to collect information about their environment, this area has been the focus of much of the prior art in virtual reality, however, it is also crucial that we provide facilities for force, torque, and touch reflection, and sound replay and 3-D localization. In this paper we present a sampling of hardware and software in the virtual environment maker's `toolbox' which can support rapidly building up of customized VR systems. We provide demonstrative examples of how some of the tools work and we speculate about VR applications and future technology needs.

  17. Virtual polytopes

    International Nuclear Information System (INIS)

    Panina, G Yu; Streinu, I

    2015-01-01

    Originating in diverse branches of mathematics, from polytope algebra and toric varieties to the theory of stressed graphs, virtual polytopes represent a natural algebraic generalization of convex polytopes. Introduced as elements of the Grothendieck group associated to the semigroup of convex polytopes, they admit a variety of geometrizations. The present survey connects the theory of virtual polytopes with other geometrical subjects, describes a series of geometrizations together with relations between them, and gives a selection of applications. Bibliography: 50 titles

  18. Virtual Savannah

    DEFF Research Database (Denmark)

    Rodil, Kasper; Eskildsen, Søren; Rehm, Matthias

    2012-01-01

    Virtual Savannah is constructed to visualize parts of a curriculum, which the educational service at Aalborg Zoo has difficulties in teaching children visiting the zoo. It contains rich media like audio, text, video and picture galleries about African ecology, but some of this episodic information...

  19. Virtual Reality.

    Science.gov (United States)

    Newby, Gregory B.

    1993-01-01

    Discusses the current state of the art in virtual reality (VR), its historical background, and future possibilities. Highlights include applications in medicine, art and entertainment, science, business, and telerobotics; and VR for information science, including graphical display of bibliographic data, libraries and books, and cyberspace.…

  20. Virtualize Me!

    Science.gov (United States)

    Waters, John K.

    2009-01-01

    John Abdelmalak, director of technology for the School District of the Chathams, was pretty sure it was time to jump on the virtualization bandwagon last year when he invited Dell to conduct a readiness assessment of his district's servers. When he saw just how little of their capacity was being used, he lost all doubt. Abdelmalak is one of many…

  1. Virtual Classroom

    DEFF Research Database (Denmark)

    Christensen, Ove

    2013-01-01

    In the Scandinavian countries: Sweden, Norway and Denmark, the project GNU (Grænseoverskridende Nordisk Undervisning, i.e. Transnational Nordic Teaching) is experimenting with ways of conducting teaching across the borders in the elementary schools. The cloud classes are organised with one class...... and benefits in regard to learning and pedagogy with virtual classroom....

  2. Personal Virtual Libraries

    Science.gov (United States)

    Pappas, Marjorie L.

    2004-01-01

    Virtual libraries are becoming more and more common. Most states have a virtual library. A growing number of public libraries have a virtual presence on the Web. Virtual libraries are a growing addition to school library media collections. The next logical step would be personal virtual libraries. A personal virtual library (PVL) is a collection…

  3. Virtual reality and anthropology

    International Nuclear Information System (INIS)

    Recheis, Wolfgang; Weber, Gerhard W.; Schaefer, Katrin; Knapp, Rudolf; Seidler, Horst; Zur Nedden, Dieter

    1999-01-01

    Since the discovery of the Tyrolean Iceman in 1991 advanced imaging and post processing techniques were successfully applied in anthropology. Specific techniques include spiral computed tomography and 3-dimensional reconstructions including stereolithographic and fused deposition modeling of volume data sets. The Iceman's skull was the first to be reproduced using stereolithography, before this method was successfully applied in preoperative planning. With the advent of high-end graphics workstations and biomedical image processing software packages, 3-dimensional reconstructions were established as a routine tool for analyzing volume data sets. These techniques opened totally new insights in the field of physical anthropology. Computed tomography became the ideal research tool to access the internal structures of various precious fossils without damaging or even touching them. Many of the most precious specimens from the species Autralopithecus (1.8-3.5 Myears), Homo heidelbergensis (200-600 kyears) or Homo neanderthalensis (40-100 kyears) were scanned during the last 5 years. Often the fossils are filled with a stone matrix or other materials. During the postprocessing routines highly advanced algorithms were used to remove virtually these incrustations. Thus it was possible to visualize the morphological structures that lie beneath the matrix. Some specimens were partially destroyed, so the missing parts were reconstructed on computer screen in order to get estimations of the brain volume and endocranial morphology, both major fields of interest in physical anthropology. Moreover the computerized form of the data allows new descriptions of morphologic structures by the means of 'geometric morphometrics'. Some of the results may change aspects and interpretations in human evolution. The introduction of new imaging and post processing techniques created a new field of research: Virtual Anthropology

  4. Sensorial Virtualization: Coupling Gaming and Virtual Environment

    NARCIS (Netherlands)

    Garbaya, S.; Miraoui, C.; Wendrich, Robert E.; Lim, T.; Stanescu, I.A.; Hauge, J.B.

    2014-01-01

    Virtual reality and virtualization are currently used to design complex systems and demonstrate that they represent the functionalities of real systems. However, the design refinement of the virtual environment (VE) and distributed virtual environment (DVE) are still time consuming and costly, as it

  5. Virtual Presenters: Towards Interactive Virtual Presentations

    NARCIS (Netherlands)

    Nijholt, Antinus; Cappellini, V.; Hemsley, J.

    2005-01-01

    We discuss having virtual presenters in virtual environments that present information to visitors of these environments. Some current research is surveyed and we will look in particular to our research in the context of a virtual meeting room where a virtual presenter uses speech, gestures, pointing

  6. Virtual materiality

    DEFF Research Database (Denmark)

    Søndergaard, Dorte Marie

    as their recounts of them and 3. the consumption of other media products like movies, reality shows, YouTube videos etc. How do we theorize ‘matter’ in such dimensions? Is it possible to theorize virtual matter as ‘materiality’ in line with any real life materiality? What conceptualization will help us understand......? These questions become crucial when we follow matter in and across real life, virtual experience, recounted imagery, night dreams, YouTube videos and even further. Some may already have recognized Phillip’s skeleton army as a transport/transformation from Lord of the Rings, DVD 3, the army which Aragon calls out....... Butler, J. (1993) Bodies that Matter. On the Discursive Limits of “Sex”. London: Routledge. Durkin, K. et al. (1998) Children, Media and Agression. Current Research in Australia and New Zealand. In: Carlson, U. & von Feilitzen, C. (red): Children and Media Violence. Yearbook from the UNESCO International...

  7. Virtual anthropology.

    Science.gov (United States)

    Weber, Gerhard W

    2015-02-01

    Comparative morphology, dealing with the diversity of form and shape, and functional morphology, the study of the relationship between the structure and the function of an organism's parts, are both important subdisciplines in biological research. Virtual anthropology (VA) contributes to comparative morphology by taking advantage of technological innovations, and it also offers new opportunities for functional analyses. It exploits digital technologies and pools experts from different domains such as anthropology, primatology, medicine, paleontology, mathematics, statistics, computer science, and engineering. VA as a technical term was coined in the late 1990s from the perspective of anthropologists with the intent of being mostly applied to biological questions concerning recent and fossil hominoids. More generally, however, there are advanced methods to study shape and size or to manipulate data digitally suitable for application to all kinds of primates, mammals, other vertebrates, and invertebrates or to issues regarding plants, tools, or other objects. In this sense, we could also call the field "virtual morphology." The approach yields permanently available virtual copies of specimens and data that comprehensively quantify geometry, including previously neglected anatomical regions. It applies advanced statistical methods, supports the reconstruction of specimens based on reproducible manipulations, and promotes the acquisition of larger samples by data sharing via electronic archives. Finally, it can help identify new, hidden traits, which is particularly important in paleoanthropology, where the scarcity of material demands extracting information from fragmentary remains. This contribution presents a current view of the six main work steps of VA: digitize, expose, compare, reconstruct, materialize, and share. The VA machinery has also been successfully used in biomechanical studies which simulate the stress and strains appearing in structures. Although

  8. Examination of the effect of ovarian radiation injury induced by hysterosalpingography on ovarian proliferating cell nuclear antigen and the radioprotective effect of amifostine: an experimental study

    Directory of Open Access Journals (Sweden)

    Can B

    2018-05-01

    Full Text Available Behzat Can,1 Remzi Atilgan,1 Sehmus Pala,1 Tuncay Kuloğlu,2 Sule Kiray,3 Nevin Ilhan4 1Department of Obstetrics and Gynecology, Firat University School of Medicine, Elazig, Turkey; 2Department of Histology and Embryology, Firat University School of Medicine, Elazig, Turkey; 3Department of Obstetrics and Gynecology, Maltepe University School of Medicine, Istanbul, Turkey; 4Department of Biochemistry, Firat University School of Medicine, Elazig, Turkey Aim: The aim of this study was to examine the effect of amifostine on cellular injury in the ovarian tissue induced by hysterosalpingography (HSG.Methods: In total, forty 4-month old female Wistar Albino rats were assigned into 8 groups. Each group contained 5 rats. Group 1 (G1: rats were decapitated without any procedure. Group 2 (G2: rats were decapitated after 3 hours of total body irradiation. Group 3 (G3: rats were decapitated 3 hours after HSG procedure. Group 4 (G4: rats were decapitated 3 hours after HSG procedure performed 30 min after receiving amifostine 200 mg/kg intraperitoneally. Group 5 (G5: rats were decapitated after 1 month without any procedure. Group 6 (G6: rats were decapitated after 1 month of total body irradiation. Group 7 (G7: rats were decapitated 1 month after HSG procedure. Group 8 (G8: rats were decapitated 1 month after HSG procedure performed 30 min after receiving amifostine 200 mg/kg intraperitoneally. After rats were decapitated under general anesthesia in all groups, blood samples were obtained and bilateral ovaries were removed. One of the ovaries was placed in 10% formaldehyde solution for histological germinal epithelial degeneration, apoptosis and proliferating cell nuclear antigen scoring. The other ovary and blood sera were stored at –80°C. TNF-α, total antioxidant status, total oxidant status, and malondialdehyde levels were studied in tissue samples and anti-mullerian hormone levels in blood samples.Results: At the end of the first month, there was

  9. Virtual automation.

    Science.gov (United States)

    Casis, E; Garrido, A; Uranga, B; Vives, A; Zufiaurre, C

    2001-01-01

    Total laboratory automation (TLA) can be substituted in mid-size laboratories by a computer sample workflow control (virtual automation). Such a solution has been implemented in our laboratory using PSM, software developed in cooperation with Roche Diagnostics (Barcelona, Spain), to this purpose. This software is connected to the online analyzers and to the laboratory information system and is able to control and direct the samples working as an intermediate station. The only difference with TLA is the replacement of transport belts by personnel of the laboratory. The implementation of this virtual automation system has allowed us the achievement of the main advantages of TLA: workload increase (64%) with reduction in the cost per test (43%), significant reduction in the number of biochemistry primary tubes (from 8 to 2), less aliquoting (from 600 to 100 samples/day), automation of functional testing, drastic reduction of preanalytical errors (from 11.7 to 0.4% of the tubes) and better total response time for both inpatients (from up to 48 hours to up to 4 hours) and outpatients (from up to 10 days to up to 48 hours). As an additional advantage, virtual automation could be implemented without hardware investment and significant headcount reduction (15% in our lab).

  10. Virtual Cystoscopy

    International Nuclear Information System (INIS)

    Mejia Restrepo, Jorge; Aldana S, Natalia; Munoz Sierra, Juan; Lopez Amaya, Juan

    2011-01-01

    Introduction: virtual cystoscopy is a minimally invasive procedure that facilitates the evaluation of the urinary tract, allowing intraluminal navigation through the urinary tract structures on the basis of CT imaging reconstructions. it allows detection of various pathologies of the system, through high-sensitivity, three-dimensional lesion visualization with some advantages over conventional cystoscopy. Objective: to describe the technique used for virtual cystoscopy at our institution,and present some representative cases. Materials and methods: We describe the main indications, advantages and limitations of the method, followed by a description of the technique used in our institution, and finally, we present five representative cases of bladder and urethral pathology. Conclusion: virtual cystoscopy is a sensitive technique for the diagnosis of bladder tumors, even those smaller than 5mm. it is the preferred method in patients who have contraindications for conventional cystoscopy, such as prostate hyperplasia, urethral stenoses and active haematuria.it is less invasive and has a lower complication rate when compared with conventional cystoscopy. It has limited use in the assessment of the mucosa and of small, flat lesions.

  11. Periodismo virtual

    Directory of Open Access Journals (Sweden)

    Carlos Morales

    2015-01-01

    Full Text Available El periodismo virtual se produce en diarios que no ofrecen noticias (concebidas como versión o reflejo de la realidad sino que crean sus propias ficciones, especialmente en primeras planas. El autor del artículo señala que esto esta sucediendo en LA NACIÓN de San José de Costa Rica, diario premiado por la inefable Sociedad Interamericana de Prensa - SIP - y periódico económicamente más importante del país.

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  13. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  14. Optical tomography of tissues

    International Nuclear Information System (INIS)

    Zimnyakov, D A; Tuchin, Valerii V

    2002-01-01

    Methods of optical tomography of biological tissues are considered, which include pulse-modulation and frequency-modulation tomography, diffusion tomography with the use of cw radiation sources, optical coherent tomography, speckle-correlation tomography of nonstationary media, and optoacoustic tomography. The method for controlling the optical properties of tissues is studied from the point of view of increasing a probing depth in optical coherent tomography. The modern state and prospects of the development of optical tomography are discussed. (review)

  15. Assessment in dogs tympanic bulla, through virtual tomographic endoscopy; Avaliacao de bulas timpanicas em caes, por meio da endoscopia tomografica virtual

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Luciana Carandina da; Sabino, Emanuelle Guidugli, E-mail: lucianacarandina@uol.com.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria. Dept. de Reproducao Animal e Radiologia Veterinaria; Vulcano, Luiz Carlos; Machado, Vania Maria de Vasconcelos [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria

    2012-07-01

    Dogs usually have problems related to the auditory canal. For the diagnosis of these pathologies, it is necessary a physical examination and, in some cases radiographic examination and computed tomography. The tympanic bulla is not easily visualized radiographically, since there is many structures of the brain overlaying the image obtained. The computed tomography has been the technique of choice to assess this structure faithfully. A new alternative assessment of the tympanic bulla is tomographic virtual endoscopy, which allows an improvement of the image obtained through the virtual tomographic technique. This paper provides information on the use of computed tomography, and a new technique, tomographic virtual endoscopy, in order to make the improvement of these techniques, and prove the reliability of these changes in the diagnosis of ear canals of dogs. Therefore, we performed the computed tomography of the tympanic bulla on healthy animals, and later performed image reconstruction in three-dimensional (3D) mode for virtual endoscopy. (author)

  16. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  17. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  18. Trust and virtual worlds

    DEFF Research Database (Denmark)

    Ess, Charles; Thorseth, May

    2011-01-01

    We collect diverse philosophical analyses of the issues and problems clustering around trust online with specific attention to establishing trust in virtual environments. The book moves forward important discussions of how virtual worlds and virtuality are to be defined and understood; the role o...... by virtuality, such as virtual child pornography. The introduction further develops a philosophical anthropology, rooted in Kantian ethics, phenomenology, virtue ethics, and feminist perspectives, that grounds a specific approach to ethical issues in virtual environments....

  19. Realidad virtual y materialidad

    OpenAIRE

    Pérez Herranz, Fernando Miguel

    2009-01-01

    1. Fenomenología de partida: Real / Simbólico / Imaginario 2. Realidad 3. Virtual 3.1. Virtual / real / posible / probable 3.2. Los contextos de la realidad virtual A) REALIDAD VIRTUAL INMERSIVA B) REALIDAD VIRTUAL NO INMERSIVA C) REALIDAD VIRTUAL Y DIGITALIZACIÓN 3.3. Cruce virtual / real 3.4. Cuestiones filosóficas 4. Materialidad 5. Materialidad y descentramiento 5.1. Ejemplos de descentramiento en los contextos de Realidad Virtual A’) DUALISMO CARTESIANO, CUERPO Y «CIBORG » B’) EL ESPÍRIT...

  20. Realidad virtual

    OpenAIRE

    García García, Alberto Luis

    2000-01-01

    Las nuevas tecnologías, basadas en el mundo digital propuesto por la informática, están cambiando nuestra forma de entender el mundo, tanto desde el punto de vista sociocultural como económico. La realidad virtual se vale de códigos icónicos, y con ello se convierte en un paso más hacia la supresión de toda barrera linguística, para llegar a conseguir la gran comunidad global. Es necesario conocer en toda su extensión, una tecnología que está cambiando el modo de comunicarnos. Estos son, a gr...

  1. Virtual Reality and the Virtual Library.

    Science.gov (United States)

    Oppenheim, Charles

    1993-01-01

    Explains virtual reality, including proper and improper uses of the term, and suggests ways that libraries might be affected by it. Highlights include elements of virtual reality systems; possible virtual reality applications, including architecture, the chemical industry, transport planning, armed forces, and entertainment; and the virtual…

  2. From virtual environment to virtual community

    NARCIS (Netherlands)

    Nijholt, Antinus; Terano, Takao; Nishida, Toyoaki; Namatame, Akira; Tsumoto, Syusaku; Ohsawa, Yukido; Washio, Takashi

    2001-01-01

    We discuss a virtual reality theater environment and its transition to a virtual community by adding domain agents and by allowing multiple users to visit this environment. The environment has been built using VRML (Virtual Reality Modeling Language). We discuss how our ideas about this environment

  3. Microsoft Virtualization Master Microsoft Server, Desktop, Application, and Presentation Virtualization

    CERN Document Server

    Olzak, Thomas; Boomer, Jason; Keefer, Robert M

    2010-01-01

    Microsoft Virtualization helps you understand and implement the latest virtualization strategies available with Microsoft products. This book focuses on: Server Virtualization, Desktop Virtualization, Application Virtualization, and Presentation Virtualization. Whether you are managing Hyper-V, implementing desktop virtualization, or even migrating virtual machines, this book is packed with coverage on all aspects of these processes. Written by a talented team of Microsoft MVPs, Microsoft Virtualization is the leading resource for a full installation, migration, or integration of virtual syste

  4. Computerized tomography

    International Nuclear Information System (INIS)

    Caille, J.M.; Salamon, G.

    1980-01-01

    As X-ray Ct becomes more commonplace, other techniques of investigation using roughly comparable hardware and software have appeared. Positron-Emission Tomography already provides indispensable physiological and physio-pathological information. Similarly, in the histo-chemical field, Nuclear Magnetic Resonance seems very promising. Some of these new techniques will no doubt shortly be considered as essential as CT in establishing accurate diagnoses non-invasively. (orig./VJ) [de

  5. Computed tomography

    International Nuclear Information System (INIS)

    Andre, M.; Resnick, D.

    1988-01-01

    Computed tomography (CT) has matured into a reliable and prominent tool for study of the muscoloskeletal system. When it was introduced in 1973, it was unique in many ways and posed a challenge to interpretation. It is in these unique features, however, that its advantages lie in comparison with conventional techniques. These advantages will be described in a spectrum of important applications in orthopedics and rheumatology

  6. First Exclusive Measurement of Deeply Virtual Compton Scattering off He4 : Toward the 3D Tomography of Nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Hattawy, M.; Baltzell, N. A.; Dupré, R.; Hafidi, K.; Stepanyan, S.; Bültmann, S.; De Vita, R.; El Alaoui, A.; El Fassi, L.; Egiyan, H.; Girod, F. X.; Guidal, M.; Jenkins, D.; Liuti, S.; Perrin, Y.; Torayev, B.; Voutier, E.; Adhikari, K. P.; Adhikari, S.; Adikaram, D.; Akbar, Z.; Amaryan, M. J.; Anefalos Pereira, S.; Armstrong, Whitney R.; Avakian, H.; Ball, J.; Bashkanov, M.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Biselli, A. S.; Boiarinov, S.; Briscoe, W. J.; Brooks, W. K.; Burkert, V. D.; Thanh Cao, Frank; Carman, D. S.; Celentano, A.; Charles, G.; Chetry, T.; Ciullo, G.; Clark, L.; Colaneri, L.; Cole, P. L.; Contalbrigo, M.; Cortes, O.; Crede, V.; D’Angelo, A.; Dashyan, N.; De Sanctis, E.; Deur, A.; Djalali, C.; Elouadrhiri, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Fersch, R.; Filippi, A.; Fleming, J. A.; Forest, T. A.; Fradi, A.; Garçon, M.; Gevorgyan, N.; Ghandilyan, Y.; Gilfoyle, G. P.; Giovanetti, K. L.; Gleason, C.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guo, L.; Hakobyan, H.; Hanretty, C.; Harrison, N.; Heddle, D.; Hicks, K.; Holtrop, M.; Hughes, S. M.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jiang, H.; Joo, K.; Joosten, S.; Keller, D.; Khachatryan, G.; Khachatryan, M.; Khandaker, M.; Kim, A.; Kim, W.; Klein, A.; Klein, F. J.; Kubarovsky, V.; Kuhn, S. E.; Kuleshov, S. V.; Lanza, L.; Lenisa, P.; Livingston, K.; Lu, H. Y.; MacGregor, I. J. D.; Markov, N.; Mayer, M.; McCracken, M. E.; McKinnon, B.; Meyer, C. A.; Meziani, Z. E.; Mineeva, T.; Mirazita, M.; Mokeev, V.; Montgomery, R. A.; Moutarde, H.; Movsisyan, A.; Munoz Camacho, C.; Nadel-Turonski, P.; Net, L. A.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Paolone, M.; Paremuzyan, R.; Park, K.; Pasyuk, E.; Phelps, E.; Phelps, W.; Pisano, S.; Pogorelko, O.; Price, J. W.; Prok, Y.; Protopopescu, D.; Ripani, M.; Ritchie, B. G.; Rizzo, A.; Rosner, G.; Rossi, P.; Sabatié, F.; Salgado, C.; Schumacher, R. A.; Seder, E.; Sharabian, Y. G.; Simonyan, A.; Skorodumina, Iu.; Smith, G. D.; Sokhan, D.; Sparveris, N.; Strauch, S.; Taiuti, M.; Ungaro, M.; Voskanyan, H.; Walford, N. K.; Watts, D. P.; Wei, X.; Weinstein, L. B.; Wood, M. H.; Zachariou, N.; Zana, L.; Zhang, J.; Zhao, Z. W.

    2017-11-01

    We report on the first measurement of the beam-spin asymmetry in the exclusive process of coherent deeply virtual Compton scattering off a nucleus. The experiment uses the 6 GeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) accelerator at Jefferson Lab incident on a pressurized He-4 gaseous target placed in front of the CEBAF Large Acceptance Spectrometer (CLAS). The scattered electron is detected by CLAS and the photon by a dedicated electromagnetic calorimeter at forward angles. To ensure the exclusivity of the process, a specially designed radial time projection chamber is used to detect the recoiling He-4 nuclei. We measure beam-spin asymmetries larger than those observed on the free proton in the same kinematic domain. From these, we are able to extract, in a model-independent way, the real and imaginary parts of the only He-4 Compton form factor, HA. This first measurement of coherent deeply virtual Compton scattering on the He-4 nucleus, with a fully exclusive final state via nuclear recoil tagging, leads the way toward 3D imaging of the partonic structure of nuclei.

  7. Emission tomography for adrenal imaging

    International Nuclear Information System (INIS)

    Britton, K.E.; Shapiro, B.; Hawkins, L.A.

    1980-01-01

    Single photon emission tomography (SPET) of the adrenals was compared to convential gamma camera images. Depths of 19 adrenals were assessed by both the lateral skin-upper kidney pole method and by SPET. Eleven patients with adrenal disorders were also studied. An advantage of using SPET was that the analogue transverse section image showed improvement over the conventional posterior view because the liver activity was well separated from the adrenal. Furthermore, non-adrenal tissue background was virtually eliminated and adrenal depth determination facilitated. (U.K.)

  8. A Virtual Class Calculus

    DEFF Research Database (Denmark)

    Ernst, Erik; Ostermann, Klaus; Cook, William Randall

    2006-01-01

    Virtual classes are class-valued attributes of objects. Like virtual methods, virtual classes are defined in an object's class and may be redefined within subclasses. They resemble inner classes, which are also defined within a class, but virtual classes are accessed through object instances...... model for virtual classes has been a long-standing open question. This paper presents a virtual class calculus, vc, that captures the essence of virtual classes in these full-fledged programming languages. The key contributions of the paper are a formalization of the dynamic and static semantics of vc...

  9. Radiological assessment of the placement of Essure® in order to reduce hysterosalpingography: Pelvic X-ray versus combined pelvic X-ray and ultrasound.

    Science.gov (United States)

    Petit, C; Vernet, T; Verpillat, P; Rubod, C; Cosson, M; Giraudet, G

    2017-10-01

    Three months after hysteroscopic sterilisation with Essure ® , a confirmation test is required to evaluate the correct location of the inserts. The test may be conducted using a pelvic ultrasound (2D or 3D) or an abdominal X-ray. Should the location not look satisfactory on these tests, a follow-up hysterosalpingography (HSG) would be required. The objective of our study is to assess whether the Essure ® 3-month confirmation test using a single X-ray or a combination of X-ray and ultrasound could reduce the use of HSG. This retrospective study examined patients who underwent birth control Essure ® procedure between 2009 and 2015 in the Gynaecological Surgery Department at the Regional University Hospital Centre (CHRU) in Lille. We divided patients into two groups based on the imaging tests performed: single X-ray (2009-2010) versus X-ray and pelvic ultrasound (2014-2015). We then compared the results of the imaging tests and the use of HSG between the two groups. One hundred and thirty-four patients were tested, of which 60 (44.8%) using a single X-ray and 74 (55.2%) using a combination of X-ray and ultrasound. We note that the combined X-ray/ultrasound test reduces significantly the number of HSG performed (26.7% versus 12.2%, P=0.04). Compared to a single X-ray, the combination of X-ray and ultrasound enables to significantly limit the use of HSG. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. Virtual colonoscopy: clinical application

    International Nuclear Information System (INIS)

    Laghi, A.

    2005-01-01

    Virtual colonoscopy (VC), also known as computed tomography Colonography (CTC), is a non-invasive test for the examination of the colon based on volumetric, thin-collimation CT acquisition of a cleansed and air-distended colon. The technique is easy, less labour-intensive than barium enema and conventional colonoscopy, and is inherently safer. Several studies demonstrate the ability of VC in the detection of colonic neoplastic lesions, not only large carcinomas, but also polyps. Currently, the most widely accepted clinical indication is incomplete or unsuccessful colonoscopy, which may be the result of redundant colon, patient intolerance to the procedure, spasm not resolving even with the use of spasmolytics, obstructing colo-rectal cancer. VC is also used to detect cancer in frail and immobile patients to avoid sedation during colonoscopy or the turning required during barium enema. The use of VC in patients under surveillance following colo-rectal cancer surgery is under investigation. Further studies are necessary in order to assess the cost-effectiveness of this approach. For colo-rectal cancer screening, a practical approach is to consider VC as a currently credible alternative screening method and as a reasonable alternative to the other colo-rectal cancer screening tests when a patient is unable or unwilling to undergo conventional colonoscopy. (orig.)

  11. Virtual colonoscopy: clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Laghi, A. [Univ. of Rome La Sapienza, Polo Didattico Pontino, Latina (Italy)

    2005-11-15

    Virtual colonoscopy (VC), also known as computed tomography Colonography (CTC), is a non-invasive test for the examination of the colon based on volumetric, thin-collimation CT acquisition of a cleansed and air-distended colon. The technique is easy, less labour-intensive than barium enema and conventional colonoscopy, and is inherently safer. Several studies demonstrate the ability of VC in the detection of colonic neoplastic lesions, not only large carcinomas, but also polyps. Currently, the most widely accepted clinical indication is incomplete or unsuccessful colonoscopy, which may be the result of redundant colon, patient intolerance to the procedure, spasm not resolving even with the use of spasmolytics, obstructing colo-rectal cancer. VC is also used to detect cancer in frail and immobile patients to avoid sedation during colonoscopy or the turning required during barium enema. The use of VC in patients under surveillance following colo-rectal cancer surgery is under investigation. Further studies are necessary in order to assess the cost-effectiveness of this approach. For colo-rectal cancer screening, a practical approach is to consider VC as a currently credible alternative screening method and as a reasonable alternative to the other colo-rectal cancer screening tests when a patient is unable or unwilling to undergo conventional colonoscopy. (orig.)

  12. Virtual Trackballs Revisited

    DEFF Research Database (Denmark)

    Henriksen, Knud; Sporring, Jon; Hornbæk, Kasper

    2004-01-01

    reviews and provides a mathematical foundation for virtual trackballs. The first, but still popular, virtual trackball was described by Chen et al. [CHECK END OF SENTENCE]. We show that the virtual trackball by Chen et al. does not rotate the object along the intended great circular arc on the virtual...... trackball and we give a correction. Another popular virtual trackball is Shoemake's quaternion implementation [CHECK END OF SENTENCE], which we show to be a special case of the virtual trackball by Chen et al.. Shoemake extends the scope of the virtual trackball to the full screen. Unfortunately, Shoemake......'s virtual trackball is inhomogeneous and discontinuous with consequences for usability. Finally, we review Bell's virtual trackball [CHECK END OF SENTENCE] and discuss studies of the usability of virtual trackballs....

  13. Virtual cystoscopy.

    Science.gov (United States)

    Mohammed, Aza; Simpson, Adam; Zamora, Ignacio; Gilliland, Leslie

    2008-07-01

    Bladder cancer is a common problem facing urologists worldwide. The gold standard for its diagnosis and follow-up is the direct visualization of the tumor using conventional cystoscopy. Despite having high sensitivity and specificity for detecting bladder cancer, conventional cystoscopy is regarded as an invasive procedure which is associated with several complications. In addition, regular follow-up of patients with bladder cancer is a financial burden on the health system. With the progressive development in diagnostic imaging and medical computer software technologies, it was possible to generate virtual reality images to aid the clinician to inspect the interior of the bladder in real time. This technology is considered as a safe test for bladder cancer diagnosis and follow-up, and it is associated with cancer detection rates comparable with conventional cystoscopy. However, it is associated with some drawbacks that limit its use in routine clinical practice at the current time. In this paper, we review the development and clinical applications of this technology.

  14. Virtual Web Services

    OpenAIRE

    Rykowski, Jarogniew

    2007-01-01

    In this paper we propose an application of software agents to provide Virtual Web Services. A Virtual Web Service is a linked collection of several real and/or virtual Web Services, and public and private agents, accessed by the user in the same way as a single real Web Service. A Virtual Web Service allows unrestricted comparison, information merging, pipelining, etc., of data coming from different sources and in different forms. Detailed architecture and functionality of a single Virtual We...

  15. Virtual button interface

    Science.gov (United States)

    Jones, J.S.

    1999-01-12

    An apparatus and method of issuing commands to a computer by a user interfacing with a virtual reality environment are disclosed. To issue a command, the user directs gaze at a virtual button within the virtual reality environment, causing a perceptible change in the virtual button, which then sends a command corresponding to the virtual button to the computer, optionally after a confirming action is performed by the user, such as depressing a thumb switch. 4 figs.

  16. Virtual reality in education

    OpenAIRE

    Minocha, Shailey; Tudor, Ana-Despina

    2017-01-01

    In this workshop-presentation, we described the evolution of virtual reality technologies and our research from 3D virtual worlds, 3D virtual environments built in gaming environments such as Unity 3D, 360-degree videos, and mobile virtual reality via Google Expeditions. For each of these four technologies, we discussed the affordances of the technologies and how they contribute towards learning and teaching. We outlined the significance of students being aware of the different virtual realit...

  17. Virtual reality - aesthetic consequences

    OpenAIRE

    Benda, Lubor

    2014-01-01

    In the present work we study aesthetic consequences of virtual reality. Exploring the fringe between fictional and virtual is one of the key goals, that will be achieved through etymologic and technologic definition of both fiction and virtual reality, fictional and virtual worlds. Both fiction and virtual reality will be then studied from aesthetic distance and aesthetic pleasure point of view. At the end, we will see the main difference as well as an common grounds between fiction and virtu...

  18. Virtual goods recommendations in virtual worlds.

    Science.gov (United States)

    Chen, Kuan-Yu; Liao, Hsiu-Yu; Chen, Jyun-Hung; Liu, Duen-Ren

    2015-01-01

    Virtual worlds (VWs) are computer-simulated environments which allow users to create their own virtual character as an avatar. With the rapidly growing user volume in VWs, platform providers launch virtual goods in haste and stampede users to increase sales revenue. However, the rapidity of development incurs virtual unrelated items which will be difficult to remarket. It not only wastes virtual global companies' intelligence resources, but also makes it difficult for users to find suitable virtual goods fit for their virtual home in daily virtual life. In the VWs, users decorate their houses, visit others' homes, create families, host parties, and so forth. Users establish their social life circles through these activities. This research proposes a novel virtual goods recommendation method based on these social interactions. The contact strength and contact influence result from interactions with social neighbors and influence users' buying intention. Our research highlights the importance of social interactions in virtual goods recommendation. The experiment's data were retrieved from an online VW platform, and the results show that the proposed method, considering social interactions and social life circle, has better performance than existing recommendation methods.

  19. Offline fusion of co-registered intravascular ultrasound and frequency domain optical coherence tomography images for the analysis of human atherosclerotic plaques

    DEFF Research Database (Denmark)

    Räber, Lorenz; Heo, Jung Ho; Radu, Maria D

    2012-01-01

    To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images.......To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images....

  20. X-ray microtome by fluorescence tomography

    CERN Document Server

    Simionovici, A S; Guenzler, F; Schrör, C; Snigirev, A; Snigireva, I; Tümmler, J; Weitkamp, T

    2001-01-01

    The X-ray fluorescence microtomography method is presented, which is capable of virtually slicing samples to obtain cross-sections of their inner structure. High precision experimental results of fluo-tomography in 'pencil-beam' geometry with up to 1.2 mu m resolution are described. Image reconstructions are based on either a simplified algebraic reconstruction method (ART) or the filtered back-projection method (FBP). Phantoms of inhomogeneous test objects as well as biological samples are successfully analyzed.

  1. The Internet and medical collaboration using virtual reality.

    Science.gov (United States)

    Liang, Wen Yau; O'Grady, Peter

    2003-01-01

    Computed Tomography (CT) provides a large amount of data but the presentation of the data to a physician can be less than satisfactory. Ideally, the image data should be available to physicians in interactive 3D to allow for improved visualization, planning and diagnosis. A virtual reality representation that not only allows for the manipulation of the image but also allows for the user to, in effect, move inside the image remotely would be ideal. In this paper the research associated with virtual reality is discussed. A formalism is then presented to create, from the CT data, the virtual reality world in the Virtual Reality Modeling Language. An implementation is described of this formalism that uses the Internet to allow for users in remote locations to view and manipulate the virtual worlds.

  2. Parsimonious Refraction Interferometry and Tomography

    KAUST Repository

    Hanafy, Sherif

    2017-02-04

    We present parsimonious refraction interferometry and tomography where a densely populated refraction data set can be obtained from two reciprocal and several infill shot gathers. The assumptions are that the refraction arrivals are head waves, and a pair of reciprocal shot gathers and several infill shot gathers are recorded over the line of interest. Refraction traveltimes from these shot gathers are picked and spawned into O(N2) virtual refraction traveltimes generated by N virtual sources, where N is the number of geophones in the 2D survey. The virtual traveltimes can be inverted to give the velocity tomogram. This enormous increase in the number of traveltime picks and associated rays, compared to the many fewer traveltimes from the reciprocal and infill shot gathers, allows for increased model resolution and a better condition number with the system of normal equations. A significant benefit is that the parsimonious survey and the associated traveltime picking is far less time consuming than that for a standard refraction survey with a dense distribution of sources.

  3. Virtual Trackballs Revisited

    OpenAIRE

    Henriksen, Knud; Sporring, Jon; Hornbæk, Kasper

    2004-01-01

    Udgivelsesdato: March/April Rotation of three-dimensional objects by a two-dimensional mouse is a typical task in computer-aided design, operation simulations, and desktop virtual reality. The most commonly used rotation technique is a virtual trackball surrounding the object and operated by the mouse pointer. This article reviews and provides a mathematical foundation for virtual trackballs. The first, but still popular, virtual trackball was described by Chen et al. [CHECK END OF SENTENC...

  4. Server virtualization solutions

    OpenAIRE

    Jonasts, Gusts

    2012-01-01

    Currently in the information technology sector that is responsible for a server infrastructure is a huge development in the field of server virtualization on x86 computer architecture. As a prerequisite for such a virtualization development is growth in server productivity and underutilization of available computing power. Several companies in the market are working on two virtualization architectures – hypervizor and hosting. In this paper several of virtualization products that use host...

  5. Virtual currencies- Real opportunities?

    OpenAIRE

    Selldahl, Sara

    2013-01-01

    The European Central Bank defines virtual currencies as ”unregulated, digital money, which is issued and usually controlled by its developers, and used and accepted among the members of a specific virtual community.” (European Central Bank, 2012, p. 5) The interest in virtual currencies has increased immensely over the last few years as they become increasingly prevalent in our society across many different industries. Up until now, the field of virtual currencies has been mainly uncharted ...

  6. Virtual reality exposure therapy

    OpenAIRE

    Rothbaum, BO; Hodges, L; Kooper, R

    1997-01-01

    It has been proposed that virtual reality (VR) exposure may be an alternative to standard in vivo exposure. Virtual reality integrates real-time computer graphics, body tracking devices, visual displays, and other sensory input devices to immerse a participant in a computer- generated virtual environment. Virtual reality exposure is potentially an efficient and cost-effective treatment of anxiety disorders. VR exposure therapy reduced the fear of heights in the first control...

  7. Interactive Virtual Cinematography

    OpenAIRE

    Burelli, Paolo

    2012-01-01

    A virtual camera represents the point-of-view of the player through which sheperceives the game world and gets feedback on her actions. Thus, the virtualcamera plays a vital role in 3D computer games and aects player experienceand enjoyability in games. Interactive virtual cinematography is the process ofvisualising the content of a virtual environment by positioning and animatingthe virtual camera in the context of interactive applications such as a computergame.Camera placement and animatio...

  8. Virtual Reality: An Overview.

    Science.gov (United States)

    Franchi, Jorge

    1994-01-01

    Highlights of this overview of virtual reality include optics; interface devices; virtual worlds; potential applications, including medicine and archaeology; problems, including costs; current research and development; future possibilities; and a listing of vendors and suppliers of virtual reality products. (Contains 11 references.) (LRW)

  9. The Virtuality Continuum Revisited

    NARCIS (Netherlands)

    Nijholt, Antinus; Traum, D.; Zhai, Sh.; Kellogg, W.

    2005-01-01

    We survey the themes and the aims of a workshop devoted to the state-of-the-art virtuality continuum. In this continuum, ranging from fully virtual to real physical environments, allowing for mixed, augmented and desktop virtual reality, several perspectives can be taken. Originally, the emphasis

  10. Virtual Reference Services.

    Science.gov (United States)

    Brewer, Sally

    2003-01-01

    As the need to access information increases, school librarians must create virtual libraries. Linked to reliable reference resources, the virtual library extends the physical collection and library hours and lets students learn to use Web-based resources in a protected learning environment. The growing number of virtual schools increases the need…

  11. Virtualization A Manager's Guide

    CERN Document Server

    Kusnetzky, Dan

    2011-01-01

    What exactly is virtualization? As this concise book explains, virtualization is a smorgasbord of technologies that offer organizations many advantages, whether you're managing extremely large stores of rapidly changing data, scaling out an application, or harnessing huge amounts of computational power. With this guide, you get an overview of the five main types of virtualization technology, along with information on security, management, and modern use cases. Topics include: Access virtualization-Allows access to any application from any deviceApplication virtualization-Enables applications

  12. Perception of Virtual Audiences.

    Science.gov (United States)

    Chollet, Mathieu; Scherer, Stefan

    2017-01-01

    A growing body of evidence shows that virtual audiences are a valuable tool in the treatment of social anxiety, and recent works show that it also a useful in public-speaking training programs. However, little research has focused on how such audiences are perceived and on how the behavior of virtual audiences can be manipulated to create various types of stimuli. The authors used a crowdsourcing methodology to create a virtual audience nonverbal behavior model and, with it, created a dataset of videos with virtual audiences containing varying behaviors. Using this dataset, they investigated how virtual audiences are perceived and which factors affect this perception.

  13. Photoacoustic Tomography

    Science.gov (United States)

    Wang, Lihong V.

    Photoacoustic tomography (PAT) refers to imaging that is based on the photoacoustic effect. Although the photoacoustic effect as a physical phenomenon was first reported on by Alexander Graham Bell in 1880 [1], PAT as an imaging technology was developed only after the advent of ultrasonic transducers, computers, and lasers [2-31]. A review on biomedical photoacoustics is available [32]. The motivation for PAT is to combine optical-absorption contrast with ultrasonic spatial resolution for deep imaging in the optical quasi-diffusive or diffusive regime. In PAT, the tissue is irradiated by usually a short-pulsed laser beam to achieve a thermal and acoustic impulse response (Fig. 19.1). Locally absorbed light is converted into heat, which is further converted to a pressure rise via thermo-elastic expansion. The initial pressure rise - determined by the local optical absorption coefficient (μ â ), fluence (ψ) and other thermal and mechanical properties - propagates as an ultrasonic wave, which is referred to as a photoacoustic wave.

  14. Axial tomography

    International Nuclear Information System (INIS)

    Brueckner, K.A.; Lewis, J.H.

    1979-01-01

    The invention relates to axial tomography, sometimes referred to as cross-sectional x-ray. The apparatus described may utilize the conventional x-ray or ultrasonic source and detector and scanning mechanism for producing the plurality of sets of radiation detector output signals. It has the means for storing the detector output signals in analog form with the signals of one set overlying the signals of another set so that signals resulting from radiation through a zone of the object being examined are summed at a corresponding zone in the storage device, typically an electronic storage tube. The summed signals are read from the storage device with a radially inversely proportional reader producing a second signal for storage, again typically in an electronic storage tube. These signals stored in the second storage device are read with Laplacian relation, with the resultant sigal being a video signal that may be connected to a TV monitor for display of the sectional image. In alternative embodiments, optical film systems and electrostatic systems are utilized. (JTA)

  15. A virtual tour of virtual reality

    Science.gov (United States)

    Harris, Margaret

    2018-03-01

    Virtual-reality glasses might still be on the starting blocks, but plenty of companies are working on the technology. Margaret Harris tries on some examples at the Photonics West show in San Francisco

  16. computed tomography features of basal ganglia and periventricular

    African Journals Online (AJOL)

    HIV is probably the most common cause of basal ganglia and periventricular calcification today. on-enhanced computed tomography (NECT) shows diffuse cerebral atrophy in 90% of cases. Bilateral, symmetrical basal ganglia calcification is seen in 30% of cases, but virtually never before 1 year of age.1. CMV (FIG.2).

  17. Virtual Reality: Principles and Applications

    OpenAIRE

    MÉRIENNE , Frédéric

    2017-01-01

    Virtual reality aims at immersing a user in a virtual environment. Dedicated virtual reality technologies of human–computer interaction enable to make the link between the user and a virtual environment in capturing the user’s motion, acting on his senses as well as computing the virtual experience in real-time. The immersion in virtual environment is evaluated through the user’s perception and reaction. Virtual reality is used in a large variety of application domains which need multisensory...

  18. ViRPET--combination of virtual reality and PET brain imaging

    Science.gov (United States)

    Majewski, Stanislaw; Brefczynski-Lewis, Julie

    2017-05-23

    Various methods, systems and apparatus are provided for brain imaging during virtual reality stimulation. In one example, among others, a system for virtual ambulatory environment brain imaging includes a mobile brain imager configured to obtain positron emission tomography (PET) scans of a subject in motion, and a virtual reality (VR) system configured to provide one or more stimuli to the subject during the PET scans. In another example, a method for virtual ambulatory environment brain imaging includes providing stimulation to a subject through a virtual reality (VR) system; and obtaining a positron emission tomography (PET) scan of the subject while moving in response to the stimulation from the VR system. The mobile brain imager can be positioned on the subject with an array of imaging photodetector modules distributed about the head of the subject.

  19. Algorithmic fundamentals of computerized tomography and of transverse analogue tomography

    International Nuclear Information System (INIS)

    Heckmann, K.

    1981-01-01

    Computerized tomography and transverse analogue tomography are two different approaches to the same goal, namely, transverse tomography. The algorithm is discussed and compared. Transverse tomography appears capable of further development, judging by this comparison. (orig.) [de

  20. [Virtual reality in neurosurgery].

    Science.gov (United States)

    Tronnier, V M; Staubert, A; Bonsanto, M M; Wirtz, C R; Kunze, S

    2000-03-01

    Virtual reality enables users to immerse themselves in a virtual three-dimensional world and to interact in this world. The simulation is different from the kind in computer games, in which the viewer is active but acts in a nonrealistic world, or on the TV screen, where we are passively driven in an active world. In virtual reality elements look realistic, they change their characteristics and have almost real-world unpredictability. Virtual reality is not only implemented in gambling dens and the entertainment industry but also in manufacturing processes (cars, furniture etc.), military applications and medicine. Especially the last two areas are strongly correlated, because telemedicine or telesurgery was originated for military reasons to operate on war victims from a secure distance or to perform surgery on astronauts in an orbiting space station. In medicine and especially neurosurgery virtual-reality methods are used for education, surgical planning and simulation on a virtual patient.

  1. Transforming Virtual Teams

    DEFF Research Database (Denmark)

    Bjørn, Pernille

    2005-01-01

    Investigating virtual team collaboration in industry using grounded theory this paper presents the in-dept analysis of empirical work conducted in a global organization of 100.000 employees where a global virtual team with participants from Sweden, United Kingdom, Canada, and North America were...... studied. The research question investigated is how collaboration is negotiated within virtual teams? This paper presents findings concerning how collaboration is negotiated within a virtual team and elaborate the difficulties due to invisible articulation work and managing multiple communities...... in transforming the virtual team into a community. It is argued that translucence in communication structures within the virtual team and between team and management is essential for engaging in a positive transformation process of trustworthiness supporting the team becoming a community, managing the immanent...

  2. Agreements in Virtual Organizations

    Science.gov (United States)

    Pankowska, Malgorzata

    This chapter is an attempt to explain the important impact that contract theory delivers with respect to the concept of virtual organization. The author believes that not enough research has been conducted in order to transfer theoretical foundations for networking to the phenomena of virtual organizations and open autonomic computing environment to ensure the controllability and management of them. The main research problem of this chapter is to explain the significance of agreements for virtual organizations governance. The first part of this chapter comprises explanations of differences among virtual machines and virtual organizations for further descriptions of the significance of the first ones to the development of the second. Next, the virtual organization development tendencies are presented and problems of IT governance in highly distributed organizational environment are discussed. The last part of this chapter covers analysis of contracts and agreements management for governance in open computing environments.

  3. Clinical applications of virtual navigation bronchial intervention.

    Science.gov (United States)

    Kajiwara, Naohiro; Maehara, Sachio; Maeda, Junichi; Hagiwara, Masaru; Okano, Tetsuya; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2018-01-01

    In patients with bronchial tumors, we frequently consider endoscopic treatment as the first treatment of choice. All computed tomography (CT) must satisfy several conditions necessary to analyze images by Synapse Vincent. To select safer and more precise approaches for patients with bronchial tumors, we determined the indications and efficacy of virtual navigation intervention for the treatment of bronchial tumors. We examined the efficacy of virtual navigation bronchial intervention for the treatment of bronchial tumors located at a variety of sites in the tracheobronchial tree using a high-speed 3-dimensional (3D) image analysis system, Synapse Vincent. Constructed images can be utilized to decide on the simulation and interventional strategy as well as for navigation during interventional manipulation in two cases. Synapse Vincent was used to determine the optimal planning of virtual navigation bronchial intervention. Moreover, this system can detect tumor location and alsodepict surrounding tissues, quickly, accurately, and safely. The feasibility and safety of Synapse Vincent in performing useful preoperative simulation and navigation of surgical procedures can lead to safer, more precise, and less invasion for the patient, and makes it easy to construct an image, depending on the purpose, in 5-10 minutes using Synapse Vincent. Moreover, if the lesion is in the parenchyma or sub-bronchial lumen, it helps to perform simulation with virtual skeletal subtraction to estimate potential lesion movement. By using virtual navigation system for simulation, bronchial intervention was performed with no complications safely and precisely. Preoperative simulation using virtual navigation bronchial intervention reduces the surgeon's stress levels, particularly when highly skilled techniques are needed to operate on lesions. This task, including both preoperative simulation and intraoperative navigation, leads to greater safety and precision. These technological instruments

  4. Virtual currencies : Real opportunities?

    OpenAIRE

    Selldahl, Sara

    2013-01-01

    AbstractThe European Central Bank defines virtual currencies as ”unregulated, digital money, which is issued and usuallycontrolled by its developers, and used and accepted among the members of a specific virtual community.”(European Central Bank, 2012, p. 5) The interest in virtual currencies has increased immensely over the last fewyears as they become increasingly prevalent in our society across many different industries. Up until now, the field ofvirtual currencies has been mainly uncharte...

  5. Real and virtual radiation

    International Nuclear Information System (INIS)

    Wolynec, E.

    1988-01-01

    Electrodisintegration cross sections related to the corresponding photonuclear process through virtual-photon spectra. A brief review of virtual-photon theory is presented. Calculations of DWBA virtual-photon spectra for finite nuclei are compared with experimental results. The multipole decomposition of electrodisintegration cross sections using these spectra is discussed and several experimental results are presented. A brief review for the bremsstrahlung cross section is also presented. (author) [pt

  6. Virtual Campus Hub technology

    DEFF Research Database (Denmark)

    Vercoulen, Frank; Badger, Merete; Monaco, Lucio

    This deliverable briefly describes which technological components have been delivered for the Virtual Campus Hub and how they can be used. A detailed discussion of the technical details of the components, how they were realized and how they fit the VCH concept can be found in deliverables D5.......4. Virtual Campus Hub Technology Evaluation Report and D6.7 The Virtual Campus Hub Concept....

  7. Post-mortem virtual estimation of free abdominal blood volume

    International Nuclear Information System (INIS)

    Ampanozi, Garyfalia; Hatch, Gary M.; Ruder, Thomas D.; Flach, Patricia M.; Germerott, Tanja; Thali, Michael J.; Ebert, Lars C.

    2012-01-01

    Purpose: The purpose of this retrospective study was to examine the reliability of virtually estimated abdominal blood volume using segmentation from postmortem computed tomography (PMCT) data. Materials and methods: Twenty-one cases with free abdominal blood were investigated by PMCT and autopsy. The volume of the blood was estimated using a manual segmentation technique (Amira, Visage Imaging, Germany) and the results were compared to autopsy data. Six of 21 cases had undergone additional post-mortem computed tomographic angiography (PMCTA). Results: The virtually estimated abdominal blood volumes did not differ significantly from those measured at autopsy. Additional PMCTA did not bias data significantly. Conclusion: Virtual estimation of abdominal blood volume is a reliable technique. The virtual blood volume estimation is a useful tool to deliver additional information in cases where autopsy is not performed or in cases where a postmortem angiography is performed

  8. Virtual Bronchoscopy for Diagnosis of Recurrent Respiratory Papillomatosis

    Directory of Open Access Journals (Sweden)

    Chin-Hung Chang

    2006-01-01

    Full Text Available Virtual bronchoscopy is a new method for viewing helical/spiral computed tomography (CT images of the tracheobronchial trees. Using commercially available software to process the CT data, the tracheobronchial trees can be inspected through a series of three-dimensional images. Recently, this technique has been increasingly used to detect benign and malignant airway stenosis. We report the findings of virtual bronchoscopy in a 41-year-old man with recurrent respiratory papillomatosis (RRP. Several tiny nodules were evident in the lower trachea. Fiberoptic bronchoscopy was performed 1 month later during a planned surgery for laryngeal papillomas, and the findings were in agreement with virtual bronchoscopy. Detection of intrabronchial spreading in RRP is important since peripheral seeding of RRP can cause complications, including recurrent pneumonia, obstructive atelectasis, hemoptysis, and, rarely, may degenerate to squamous cell carcinoma. Virtual bronchoscopy is an alternative method for inspecting the tracheobronchial trees in patients with RRP when laryngeal papillomas impede fiberoptic bronchoscopy.

  9. High availability using virtualization

    International Nuclear Information System (INIS)

    Calzolari, Federico; Arezzini, Silvia; Ciampa, Alberto; Mazzoni, Enrico; Domenici, Andrea; Vaglini, Gigliola

    2010-01-01

    High availability has always been one of the main problems for a data center. Till now high availability was achieved by host per host redundancy, a highly expensive method in terms of hardware and human costs. A new approach to the problem can be offered by virtualization. Using virtualization, it is possible to achieve a redundancy system for all the services running on a data center. This new approach to high availability allows the running virtual machines to be distributed over a small number of servers, by exploiting the features of the virtualization layer: start, stop and move virtual machines between physical hosts. The 3RC system is based on a finite state machine, providing the possibility to restart each virtual machine over any physical host, or reinstall it from scratch. A complete infrastructure has been developed to install operating system and middleware in a few minutes. To virtualize the main servers of a data center, a new procedure has been developed to migrate physical to virtual hosts. The whole Grid data center SNS-PISA is running at the moment in virtual environment under the high availability system.

  10. Secure Virtual Enclaves

    National Research Council Canada - National Science Library

    Shands, Deborah

    2002-01-01

    The Secure Virtual Enclaves (SVE) collaboration infrastructure allows multiple organizations to share their distributed application resources, while respecting organizational autonomy over local resources...

  11. Virtual Environments for Training

    National Research Council Canada - National Science Library

    Stiles, R

    1998-01-01

    .... Progress on productization of the VET Training Studio software includes increased robustness for Vista virtual environment display and interaction services, a new capability to use the STEVE visual...

  12. Photon virtual bound state

    International Nuclear Information System (INIS)

    Inoue, J.; Ohtaka, K.

    2004-01-01

    We study virtual bound states in photonics, which are a vectorial extension of electron virtual bound states. The condition for these states is derived. It is found that the Mie resonant state which satisfies the condition that the size parameter is less than the angular momentum should be interpreted as a photon virtual bound state. In order to confirm the validity of the concept, we compare the photonic density of states, the width of which represents the lifetime of the photon virtual bound states, with numerical results

  13. Virtual Training Devices Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Virtual Training Devices (VTD) Laboratory at the Life Cycle Software Engineering Center, Picatinny Arsenal, provides a software testing and support environment...

  14. Virtual Reality Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Performs basic and applied research in interactive 3D computer graphics, including visual analytics, virtual environments, and augmented reality (AR). The...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  16. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  18. Super-virtual refraction interferometry: Theory

    KAUST Repository

    Bharadwaj, Pawan

    2011-01-01

    Inverting for the subsurface velocity distribution by refraction traveltime tomography is a well-accepted imaging method by both the exploration and earthquake seismology communities. A significant drawback, however, is that the recorded traces become noisier with increasing offset from the source position, and so prevents accurate picking of traveltimes in far-offset traces. To enhance the signal-to-noise ratio of the far-offset traces, we present the theory of super-virtual refraction interferometry where the signal-to-noise ratio (SNR) of far-offset head-wave arrivals can be theoretically increased by a factor proportional to N; here, N is the number of receiver and source positions associated with the recording and generation of the head-wave arrival. There are two steps to this methodology: correlation and summation of the data to generate traces with virtual head-wave arrivals, followed by the convolution of the data with the virtual traces to create traces with super-virtual head-wave arrivals. This method is valid for any medium that generates head-wave arrivals. There are at least three significant benefits to this methodology: 1). enhanced SNR of far-offset traces so the first-arrival traveltimes of the noisy far-offset traces can be more reliably picked to extend the useful aperture of data, 2). the SNR of head waves in a trace that arrive after the first arrival can be enhanced for accurate traveltime picking and subsequent inversion by traveltime tomography, and 3). common receiver-pair gathers can be analyzed to detect the presence of diving waves in the first arrivals, which can be used to assess the nature of the refracting boundary. © 2011 Society of Exploration Geophysicists.

  19. Review of muon tomography

    International Nuclear Information System (INIS)

    Feng Hanliang; Jiao Xiaojing

    2010-01-01

    As a new detection technology, Muon tomography has some potential benefits, such as being able to form a three- dimensional image, without radiation, low cost, fast detecting etc. Especially, muon tomography will play an important role in detecting nuclear materials. It introduces the theory of Muon tomography, its advantages and the Muon tomography system developed by decision sciences corporation and Los Alamos national laboratory. (authors)

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  1. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  4. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  5. A Virtual History of Mauritius

    African Journals Online (AJOL)

    admpather

    University of Mauritius, Réduit, Mauritius. 116. A Virtual History ... out will be presented. Keywords: Virtual Heritage, Virtual Reality, Archaeology, Mauritius ... money would better be spent on other major education and IT development projects ...

  6. The virtual GULLIVER project

    NARCIS (Netherlands)

    Trappl, R.; Nijholt, Antinus; Stuk, M.; Zwiers, Jakob

    2002-01-01

    In this paper we discuss our virtual reality project Gulliver. This project is part of a more comprehensive project conceived by two artists, Matjaž Štuk and Alena Hudcovicová, called “Gulliver’s Museum of Living Art��?. Our part of the project involves a virtual reality version of Swift’s Gulliver

  7. A Virtual Good Idea

    Science.gov (United States)

    Bolch, Matt

    2009-01-01

    School districts across the country have always had to do more with less. Funding goes only so far, leaving administrators and IT staff to find innovative ways to save money while maintaining a high level of academic quality. Creating virtual servers accomplishes both tasks, district technology personnel say. Virtual environments not only allow…

  8. 10 Myths of Virtualization

    Science.gov (United States)

    Schaffhauser, Dian

    2012-01-01

    Half of servers in higher ed are virtualized. But that number's not high enough for Link Alander, interim vice chancellor and CIO at the Lone Star College System (Texas). He aspires to see 100 percent of the system's infrastructure requirements delivered as IT services from its own virtualized data centers or other cloud-based operators. Back in…

  9. Designing Virtual Learning Environments

    DEFF Research Database (Denmark)

    Veirum, Niels Einar

    2003-01-01

    The main objective of this working paper is to present a conceptual model for media integrated communication in virtual learning environments. The model for media integrated communication is very simple and identifies the necessary building blocks for virtual place making in a synthesis of methods...

  10. OVERLAPPING VIRTUAL CADASTRAL DOCUMENTATION

    Directory of Open Access Journals (Sweden)

    Madalina - Cristina Marian

    2013-12-01

    Full Text Available Two cadastrale plans of buildings, can overlap virtual. Overlap is highlighted when digital reception. According to Law no. 7/1996 as amended and supplemented, to solve these problems is by updating the database graphs, the repositioning. This paper addresses the issue of overlapping virtual cadastre in the history of the period 1999-2012.

  11. Taxation of virtual currency

    NARCIS (Netherlands)

    Bal, Aleksandra Marta

    2014-01-01

    The Information Age has created a new concept of money – virtual currencies existing solely in the cyberspace in the form of intangible computer code. The most prominent virtual currency scheme, Bitcoin, grabbed the public attention as its value skyrocketed at the beginning of 2012. Whereas Bitcoin

  12. Virtual Company and Modelbank

    DEFF Research Database (Denmark)

    Thorsteinsson, Uffe

    1996-01-01

    Ansøgning til Socrates programmet vedr. Tematisk netværk inden for området Virtual Company and Modelbank......Ansøgning til Socrates programmet vedr. Tematisk netværk inden for området Virtual Company and Modelbank...

  13. Virtual Pediatric Hospital

    Science.gov (United States)

    ... Thoracopaedia - An Imaging Encyclopedia of Pediatric Thoracic Disease Virtual Pediatric Hospital is the Apprentice's Assistant™ Last revised ... pediatric resources: GeneralPediatrics.com | PediatricEducation.org | SearchingPediatrics.com Virtual Pediatric Hospital is curated by Donna M. D' ...

  14. Virtual School Counseling

    Science.gov (United States)

    Osborn, Debra S.; Peterson, Gary W.; Hale, Rebecca R.

    2015-01-01

    The advent of virtual schools opens doors to opportunity for delivery of student services via the Internet. Through the use of structured interviews with four practicing Florida virtual school counselors, and a follow-up survey, the authors examined the experiences and reflections of school counselors who are employed full time in a statewide…

  15. State Virtual Libraries

    Science.gov (United States)

    Pappas, Marjorie L.

    2003-01-01

    Virtual library? Electronic library? Digital library? Online information network? These all apply to the growing number of Web-based resource collections managed by consortiums of state library entities. Some, like "INFOhio" and "KYVL" ("Kentucky Virtual Library"), have been available for a few years, but others are just starting. Searching for…

  16. Who Benefits from Virtuality?

    Science.gov (United States)

    Harper, Barry; Hedberg, John G.; Wright, Rob

    2000-01-01

    Discusses the use of constructivist frameworks to develop effective and successful learning environments, including educational software. Topics include technology supporting reform; virtuality and multimedia; attributes of interactive multimedia and virtual reality; and examples of context and learner active participation. (Contains 35…

  17. Virtual Reality in Psychology

    Science.gov (United States)

    Foreman, Nigel

    2009-01-01

    The benefits of using virtual environments (VEs) in psychology arise from the fact that movements in virtual space, and accompanying perceptual changes, are treated by the brain in much the same way as those in equivalent real space. The research benefits of using VEs, in areas of psychology such as spatial learning and cognition, include…

  18. Virtual reality musical instruments

    DEFF Research Database (Denmark)

    Serafin, Stefania; Erkut, Cumhur; Kojs, Juraj

    2016-01-01

    The rapid development and availability of low cost technologies has created a wide interest in virtual reality (VR), but how to design and evaluate multisensory interactions in VR remains as a challenge. In this paper, we focus on virtual reality musical instruments, present an overview of our...

  19. Virtual Seminar Room

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Fosgerau, Anders; Hansen, Peter Søren Kirk

    1999-01-01

    The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented.......The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented....

  20. Virtual Peace Education

    Science.gov (United States)

    Firer, Ruth

    2008-01-01

    This article is based on the convictions that peace education is the basis for any sustainable non-violent relations between parties in a conflict, and that virtual peace education is almost the only feasible way to practise peace education in an open violent conflict as is the current Israeli/Palestinians one. Moreover, virtual peace education…

  1. Representing Large Virtual Worlds

    NARCIS (Netherlands)

    Kol, T.R.

    2018-01-01

    The ubiquity of large virtual worlds and their growing complexity in computer graphics require efficient representations. This means that we need smart solutions for the underlying storage of these complex environments, but also for their visualization. How the virtual world is best stored and how

  2. VEM: Virtual Enterprise Methodology

    DEFF Research Database (Denmark)

    Tølle, Martin; Vesterager, Johan

    2003-01-01

    This chapter presents a virtual enterprise methodology (VEM) that outlines activities to consider when setting up and managing virtual enterprises (VEs). As a methodology the VEM helps companies to ask the right questions when preparing for and setting up an enterprise network, which works...

  3. The Erasmus Virtual Campus

    Science.gov (United States)

    Isakeit, D.

    2002-02-01

    The Erasmus Virtual Campus was inaugurated in September 2000 to bring together scientists and engineers interested in using the International Space Station and other facilities for their research. It also provides the foundation for creating Virtual Institutes in selected scientific disciplines. The current capabilities of the Campus are highlighted, along with plans for the future.

  4. Super-Virtual Refraction Interferometric Redatuming: Enhancing the Refracted Energy

    KAUST Repository

    Aldawood, Ali

    2012-02-26

    onshore seismic data processing. Refraction tomography is becoming a common way to estimate an accurate near surface velocity model. One of the problems with refraction tomography is the low signal to noise ration in far offset data. To improve, we propose using super-virtual refraction interferometry to enhance the weak energy at far offsets. We use Interferometric Green\\'s functions to redatum sources by cross-correlating two traces recorded at receiver stations, A and B, from a source at location W. The result is a redatumed trace with a virtual source at A and a receiver at B, which can also be obtained by correlating two traces recorded at A and B from different shots. Stacking them would enhance the signal-to-noise ratio of this "virtual" trace. We next augment redatuming with convolution and stacking. The trace recorded at B from a virtual source at A is convolved with the original trace recorded at A from a source at W. The result is a "super-virtual" trace at B in the far-offset from a source at W. Stacking N traces gives a vN-improvement. We applied our method to noisy synthetic and field data recorded over a complex near-surface and we could pick more traces at far offsets. It was possible to accommodate more picks resulting in a better subsurface coverage

  5. Super-Virtual Refraction Interferometric Redatuming: Enhancing the Refracted Energy

    KAUST Repository

    Aldawood, Ali; Alshuhail, Abdulrahman Abdullatif Abdulrahman; Hanafy, Sherif

    2012-01-01

    onshore seismic data processing. Refraction tomography is becoming a common way to estimate an accurate near surface velocity model. One of the problems with refraction tomography is the low signal to noise ration in far offset data. To improve, we propose using super-virtual refraction interferometry to enhance the weak energy at far offsets. We use Interferometric Green's functions to redatum sources by cross-correlating two traces recorded at receiver stations, A and B, from a source at location W. The result is a redatumed trace with a virtual source at A and a receiver at B, which can also be obtained by correlating two traces recorded at A and B from different shots. Stacking them would enhance the signal-to-noise ratio of this "virtual" trace. We next augment redatuming with convolution and stacking. The trace recorded at B from a virtual source at A is convolved with the original trace recorded at A from a source at W. The result is a "super-virtual" trace at B in the far-offset from a source at W. Stacking N traces gives a vN-improvement. We applied our method to noisy synthetic and field data recorded over a complex near-surface and we could pick more traces at far offsets. It was possible to accommodate more picks resulting in a better subsurface coverage

  6. Organization Virtual or Networked?

    Directory of Open Access Journals (Sweden)

    Rūta Tamošiūnaitė

    2013-08-01

    Full Text Available Purpose—to present distinction between “virtual organization” and “networked organization”; giving their definitions.Design/methodology/approach—review of previous researches, systemic analyses of their findings and synthesis of distinctive characteristics of ”virtual organization” and “networked organization.”Findings—the main result of the research is key diverse features separating ”virtual organization” and ”networked organization.” Definitions of “virtual organization” and “networked organization” are presented.Originality/Value—distinction between “virtual organization” and “networked organization” creates possibilities to use all advantages of those types of organizations and gives foundation for deeper researches in this field.Research type: general review.

  7. Designing Virtual Worlds

    DEFF Research Database (Denmark)

    Gürsimsek, Remzi Ates

    2014-01-01

    The online social platforms known as virtual worlds present their users various affordances for avatar based co-presence, social interaction and provide tools for collaborative content creation, including objects, textures and animations. The users of these worlds navigate their avatars as personal...... the audio-visual characteristics of designing in multi-user virtual environments generate experiential, interpersonal and textual meaning potentials....... mediators in 3D virtual space to collaborate and co-design the digital content. These co-designers are also the residents of these worlds, as they socialize by building inworld friendships. This article presents a social semiotic analysis of the three-dimensional virtual places and artifacts in the virtual...

  8. Virtual Organizations: Beyond Network Organization

    Directory of Open Access Journals (Sweden)

    Liviu Gabriel CRETU

    2006-01-01

    Full Text Available One of the most used buzz-words in (e-business literature of the last decade is virtual organization. The term "virtual" can be identified in all sorts of combinations regarding the business world. From virtual products to virtual processes or virtual teams, everything that is “touched” by the computer’s processing power instantly becomes virtual. Moreover, most of the literature treats virtual and network organizations as being synonyms. This paper aims to draw a much more distinctive line between the two concepts. Providing a more coherent description of what virtual organization might be is also one of our intentions.

  9. Virtual Planning and Intraoperative Navigation in Craniomaxillofacial Surgery

    Directory of Open Access Journals (Sweden)

    Jorge Guiñales

    2017-08-01

    Full Text Available Surgery planning assisted by computer represents one important example of the collaboration between surgeons and engineers. Virtual planning allows surgeons to pre-do the surgery by working over a virtual 3D model of the patient obtained through a computer tomography. Through surgical navigation, surgeons are helped while working with deep structures and can check if they are following accurately the surgical plan. These assistive tools are crucial in the field of facial reconstructive surgery. This paper describes two cases, one related to orbital fractures and another one related to oncological patients, showing the advantages that these tools provide, specifically when used for craniomaxillofacial surgery.

  10. Virtual reality simulator for vitreoretinal surgery using integrated OCT data

    Directory of Open Access Journals (Sweden)

    Kozak I

    2014-03-01

    Full Text Available Igor Kozak,1 Pat Banerjee,2 Jia Luo,2 Cristian Luciano21King Khaled Eye Specialist Hospital, Vitreoretinal Division, Riyadh, Kingdom of Saudi Arabia; 2College of Engineering, University of Illinois at Chicago, Chicago, IL, USAAbstract: Operative practice using surgical simulators has become a part of training in many surgical specialties, including ophthalmology. We introduce a virtual reality retina surgery simulator capable of integrating optical coherence tomography (OCT scans from real patients for practicing vitreoretinal surgery using different pathologic scenarios.Keywords: optical coherence tomography

  11. Virtual Machine Logbook - Enabling virtualization for ATLAS

    International Nuclear Information System (INIS)

    Yao Yushu; Calafiura, Paolo; Leggett, Charles; Poffet, Julien; Cavalli, Andrea; Frederic, Bapst

    2010-01-01

    ATLAS software has been developed mostly on CERN linux cluster lxplus or on similar facilities at the experiment Tier 1 centers. The fast rise of virtualization technology has the potential to change this model, turning every laptop or desktop into an ATLAS analysis platform. In the context of the CernVM project we are developing a suite of tools and CernVM plug-in extensions to promote the use of virtualization for ATLAS analysis and software development. The Virtual Machine Logbook (VML), in particular, is an application to organize work of physicists on multiple projects, logging their progress, and speeding up ''context switches'' from one project to another. An important feature of VML is the ability to share with a single 'click' the status of a given project with other colleagues. VML builds upon the save and restore capabilities of mainstream virtualization software like VMware, and provides a technology-independent client interface to them. A lot of emphasis in the design and implementation has gone into optimizing the save and restore process to makepractical to store many VML entries on a typical laptop disk or to share a VML entry over the network. At the same time, taking advantage of CernVM's plugin capabilities, we are extending the CernVM platform to help increase the usability of ATLAS software. For example, we added the ability to start the ATLAS event display on any computer running CernVM simply by clicking a button in a web browser. We want to integrate seamlessly VML with CernVM unique file system design to distribute efficiently ATLAS software on every physicist computer. The CernVM File System (CVMFS) download files on-demand via HTTP, and cache it locally for future use. This reduces by one order of magnitude the download sizes, making practical for a developer to work with multiple software releases on a virtual machine.

  12. [Virtual + 1] * Reality

    Science.gov (United States)

    Beckhaus, Steffi

    Virtual Reality aims at creating an artificial environment that can be perceived as a substitute to a real setting. Much effort in research and development goes into the creation of virtual environments that in their majority are perceivable only by eyes and hands. The multisensory nature of our perception, however, allows and, arguably, also expects more than that. As long as we are not able to simulate and deliver a fully sensory believable virtual environment to a user, we could make use of the fully sensory, multi-modal nature of real objects to fill in for this deficiency. The idea is to purposefully integrate real artifacts into the application and interaction, instead of dismissing anything real as hindering the virtual experience. The term virtual reality - denoting the goal, not the technology - shifts from a core virtual reality to an “enriched” reality, technologically encompassing both the computer generated and the real, physical artifacts. Together, either simultaneously or in a hybrid way, real and virtual jointly provide stimuli that are perceived by users through their senses and are later formed into an experience by the user's mind.

  13. Virtualization Security Combining Mandatory Access Control and Virtual Machine Introspection

    OpenAIRE

    Win, Thu Yein; Tianfield, Huaglory; Mair, Quentin

    2014-01-01

    Virtualization has become a target for attacks in cloud computing environments. Existing approaches to protecting the virtualization environment against the attacks are limited in protection scope and are with high overheads. This paper proposes a novel virtualization security solution which aims to provide comprehensive protection of the virtualization environment.

  14. Turbocharging Quantum Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Gamble, John King [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Nielsen, Erik [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Maunz, Peter Lukas Wilhelm [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Scholten, Travis L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Rudinger, Kenneth Michael [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography suffers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. We describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more effectively detect and characterize quantum noise using carefully tailored ensembles of input states.

  15. The Virtual Dressing Room

    DEFF Research Database (Denmark)

    Holte, Michael Boelstoft

    2013-01-01

    This paper presents a review of recent developments and future perspectives, addressing the problem of creating a virtual dressing room. First, we review the current state-of-the-art of exiting solutions and discuss their applicability and limitations. We categorize the exiting solutions into three...... kinds: (1) virtual real-time 2D image/video techniques, where the consumer gets to superimpose the clothes on their real-time video to visualize themselves wearing the clothes. (2) 2D and 3D mannequins, where a web-application uses the body measurements provided by the customer, to superimpose...... and their demands to a virtual dressing room....

  16. The Virtual Dressing Room

    DEFF Research Database (Denmark)

    Holte, Michael Boelstoft; Gao, Yi; Petersson, Eva

    2015-01-01

    This paper presents the design and evaluation of a usability and user experience test of a virtual dressing room. First, we motivate and introduce our recent developed prototype of a virtual dressing room. Next, we present the research and test design grounded in related usability and user...... experience studies. We give a description of the experimental setup and the execution of the designed usability and user experience test. To this end, we report interesting results and discuss the results with respect to user-centered design and development of a virtual dressing room....

  17. Virtual neutron scattering experiments

    DEFF Research Database (Denmark)

    Overgaard, Julie Hougaard; Bruun, Jesper; May, Michael

    2017-01-01

    . In the last week of the course, students travel to a large-scale neutron scattering facility to perform real neutron scattering experiments. Through student interviews and survey answers, we argue, that the virtual training prepares the students to engage more fruitfully with experiments by letting them focus......We describe how virtual experiments can be utilized in a learning design that prepares students for hands-on experiments at large-scale facilities. We illustrate the design by showing how virtual experiments are used at the Niels Bohr Institute in a master level course on neutron scattering...

  18. Virtual Reality Musical Instruments

    DEFF Research Database (Denmark)

    Serafin, Stefania; Erkut, Cumhur; Kojs, Juraj

    2016-01-01

    The rapid development and availability of low-cost technologies have created a wide interest in virtual reality. In the field of computer music, the term “virtual musical instruments” has been used for a long time to describe software simulations, extensions of existing musical instruments......, and ways to control them with new interfaces for musical expression. Virtual reality musical instruments (VRMIs) that include a simulated visual component delivered via a head-mounted display or other forms of immersive visualization have not yet received much attention. In this article, we present a field...

  19. Virtual Trondheim: A Virtual Environment for Tourism and Education

    OpenAIRE

    Jose, Dawn Alphonse

    2015-01-01

    The purpose of this study is to investigate whether educational activities in tourism can be supported by virtual reality technologies, using virtual world frameworks. Settings of virtual world of SecondLife and a recent Virtual Reality technology known as Oculus Rift were used in the thesis work with the city of Trondheim as the main context. Theoretical studies on Virtual Reality systems were conducted and data for the research were obtained through empirical studies condu...

  20. Setting up virtual private network

    International Nuclear Information System (INIS)

    Huang Hongmei; Zhang Chengjun

    2003-01-01

    Setting up virtual private network for business enterprise provides a low cost network foundation, increases enterprise's network function and enlarges its private scope. The text introduces virtual private network's principal, privileges and protocols that use in virtual private network. At last, this paper introduces several setting up virtual private network's technologies which based on LAN

  1. Setting up virtual private network

    International Nuclear Information System (INIS)

    Huang Hongmei; Zhang Chengjun

    2003-01-01

    Setting up virtual private network for business enterprise provides a low cost network foundation, increases enterprise network function and enlarges its private scope. This text introduces virtual private network principal, privileges and protocols applied in virtual private network. At last, this paper introduces several setting up virtual private network technologies which is based on LAN

  2. Virtual Museums as Educational Tool

    DEFF Research Database (Denmark)

    2007-01-01

    Virtual Museums as Educational Tool On this web site you will find a collection of resources on virtual museums. The web site is meant to be a knowledge base for people with interest in museums, virtuality and education, and how virtual museums may contribute to adult education and lifelong...

  3. Virtual reality simulator for vitreoretinal surgery using integrated OCT data

    OpenAIRE

    Kozak, Igor; Banerjee,Pat; Luo,Jia; Luciano,Cristian

    2014-01-01

    Igor Kozak,1 Pat Banerjee,2 Jia Luo,2 Cristian Luciano21King Khaled Eye Specialist Hospital, Vitreoretinal Division, Riyadh, Kingdom of Saudi Arabia; 2College of Engineering, University of Illinois at Chicago, Chicago, IL, USAAbstract: Operative practice using surgical simulators has become a part of training in many surgical specialties, including ophthalmology. We introduce a virtual reality retina surgery simulator capable of integrating optical coherence tomography (OCT) scans from real p...

  4. Virtual neutron scattering experiments

    DEFF Research Database (Denmark)

    Overgaard, Julie Hougaard; Bruun, Jesper; May, Michael

    2016-01-01

    We describe how virtual experiments can be utilized in a learning design that prepares students for hands-on experiments at large-scale facilities. We illustrate the design by showing how virtual experiments are used at the Niels Bohr Institute in a master level course on neutron scattering....... In the last week of the course, students travel to a large-scale neutron scattering facility to perform real neutron scattering experiments. Through student interviews and survey answers, we argue, that the virtual training prepares the students to engage more fruitfully with experiments by letting them focus...... on physics and data rather than the overwhelming instrumentation. We argue that this is because they can transfer their virtual experimental experience to the real-life situation. However, we also find that learning is still situated in the sense that only knowledge of particular experiments is transferred...

  5. Virtual Factory Testbed

    Data.gov (United States)

    Federal Laboratory Consortium — The Virtual Factory Testbed (VFT) is comprised of three physical facilities linked by a standalone network (VFNet). The three facilities are the Smart and Wireless...

  6. Virtual Telescope Alignment System

    Data.gov (United States)

    National Aeronautics and Space Administration — Next-generation space telescopes require two spacecraft to fly in a coordinated fashion in space forming a virtual telescope. Achieving and maintaining this precise...

  7. Virtual Project Teams

    DEFF Research Database (Denmark)

    Bjørn, Pernille

    technology in six real-life virtual teams, two in industry and four in education, applying interpretative research and action research methods. Two main lines of investigation are pursued: the first involves an examination of the organisational issues related to groupware adaptation in virtual project teams......, professional disciplines, time differences and technology. This thesis comprises a general introduction, referred to as the summary report, and seven research papers, which deal in detail with the results and findings of the empirical cases. The summary report provides a general introduction to the research......, while the second looks at the social context and practices of virtual project teams. Two of the key findings are 1) that the process of groupware adaptation by virtual project teams can be viewed as a process of expanding and aligning the technological frames of the participants, which includes mutual...

  8. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  9. Virtual Reality Lab Assistant

    Science.gov (United States)

    Saha, Hrishikesh; Palmer, Timothy A.

    1996-01-01

    Virtual Reality Lab Assistant (VRLA) demonstration model is aligned for engineering and material science experiments to be performed by undergraduate and graduate students in the course as a pre-lab simulation experience. This will help students to get a preview of how to use the lab equipment and run experiments without using the lab hardware/software equipment. The quality of the time available for laboratory experiments can be significantly improved through the use of virtual reality technology.

  10. Quantum Virtual Machine (QVM)

    Energy Technology Data Exchange (ETDEWEB)

    2016-11-18

    There is a lack of state-of-the-art HPC simulation tools for simulating general quantum computing. Furthermore, there are no real software tools that integrate current quantum computers into existing classical HPC workflows. This product, the Quantum Virtual Machine (QVM), solves this problem by providing an extensible framework for pluggable virtual, or physical, quantum processing units (QPUs). It enables the execution of low level quantum assembly codes and returns the results of such executions.

  11. Taxation of virtual currency

    OpenAIRE

    Bal, Aleksandra Marta

    2014-01-01

    The Information Age has created a new concept of money – virtual currencies existing solely in the cyberspace in the form of intangible computer code. The most prominent virtual currency scheme, Bitcoin, grabbed the public attention as its value skyrocketed at the beginning of 2012. Whereas Bitcoin has many proper ties that could make it an ideal currency for mainstream consumers and merchants, its main drawback is lack of clarity regarding its legal status and tax treatment. The European Cen...

  12. Virtual classroom project

    OpenAIRE

    Gmeiner, Nicholas

    2017-01-01

    This project aims to provide students with disabilities the same in class learning experience through virtual reality technology, 360-degree video capture, and the use of Arduino units. These technologies will be combined to facilitate communication between teachers in physical classrooms with students in virtual classrooms. The goal is to provide a person who is affected by a disability (which makes it hard to be in a traditional classroom) the same benefits of a safe and interactive learnin...

  13. Meaning of Interior Tomography

    Science.gov (United States)

    Wang, Ge; Yu, Hengyong

    2013-01-01

    The classic imaging geometry for computed tomography is for collection of un-truncated projections and reconstruction of a global image, with the Fourier transform as the theoretical foundation that is intrinsically non-local. Recently, interior tomography research has led to theoretically exact relationships between localities in the projection and image spaces and practically promising reconstruction algorithms. Initially, interior tomography was developed for x-ray computed tomography. Then, it has been elevated as a general imaging principle. Finally, a novel framework known as “omni-tomography” is being developed for grand fusion of multiple imaging modalities, allowing tomographic synchrony of diversified features. PMID:23912256

  14. Single photon emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-09-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) imaging technique. Content: 1 - Introduction: anatomic, functional and molecular imaging; Principle and role of functional or molecular imaging; 2 - Radiotracers: chemical and physical constraints, main emitters, radioisotopes production, emitters type and imaging techniques; 3 - Single photon emission computed tomography: gamma cameras and their components, gamma camera specifications, planar single photon imaging characteristics, gamma camera and tomography; 4 - Quantification in single photon emission tomography: attenuation, scattering, un-stationary spatial resolution, partial volume effect, movements, others; 5 - Synthesis and conclusion

  15. Virtual Prototyping at CERN

    Science.gov (United States)

    Gennaro, Silvano De

    The VENUS (Virtual Environment Navigation in the Underground Sites) project is probably the largest Virtual Reality application to Engineering design in the world. VENUS is just over one year old and offers a fully immersive and stereoscopic "flythru" of the LHC pits for the proposed experiments, including the experimental area equipment and the surface models that are being prepared for a territorial impact study. VENUS' Virtual Prototypes are an ideal replacement for the wooden models traditionally build for the past CERN machines, as they are generated directly from the EUCLID CAD files, therefore they are totally reliable, they can be updated in a matter of minutes, and they allow designers to explore them from inside, in a one-to-one scale. Navigation can be performed on the computer screen, on a stereoscopic large projection screen, or in immersive conditions, with an helmet and 3D mouse. By using specialised collision detection software, the computer can find optimal paths to lower each detector part into the pits and position it to destination, letting us visualize the whole assembly probess. During construction, these paths can be fed to a robot controller, which can operate the bridge cranes and build LHC almost without human intervention. VENUS is currently developing a multiplatform VR browser that will let the whole HEP community access LHC's Virtual Protoypes over the web. Many interesting things took place during the conference on Virtual Reality. For more information please refer to the Virtual Reality section.

  16. Interpretations of virtual reality.

    Science.gov (United States)

    Voiskounsky, Alexander

    2011-01-01

    University students were surveyed to learn what they know about virtual realities. The two studies were administered with a half-year interval in which the students (N=90, specializing either in mathematics and science, or in social science and humanities) were asked to name particular examples of virtual realities. The second, but not the first study, was administered after the participants had the chance to see the movie "Avatar" (no investigation was held into whether they really saw it). While the students in both studies widely believed that activities such as social networking and online gaming represent virtual realities, some other examples provided by the students in the two studies differ: in the second study the participants expressed a better understanding of the items related to virtual realities. At the same time, not a single participant reported particular psychological states (either regular or altered) as examples of virtual realities. Profound popularization efforts need to be done to acquaint the public, including college students, with virtual realities and let the public adequately understand how such systems work.

  17. Virtualization Technologies for the Business

    OpenAIRE

    Sabina POPESCU

    2011-01-01

    There is a new trend of change in today's IT industry. It's called virtualization. In datacenter virtualization can occur on several levels, but the type of virtualization has created this trend change is the operating system offered or server virtualization. OS virtualization technologies come in two forms. First, there is a software component that is used to simulate a natural machine that has total control of an operating system operating on the host equipment. The second is a hypervisor, ...

  18. Virtual Machine in Automation Projects

    OpenAIRE

    Xing, Xiaoyuan

    2010-01-01

    Virtual machine, as an engineering tool, has recently been introduced into automation projects in Tetra Pak Processing System AB. The goal of this paper is to examine how to better utilize virtual machine for the automation projects. This paper designs different project scenarios using virtual machine. It analyzes installability, performance and stability of virtual machine from the test results. Technical solutions concerning virtual machine are discussed such as the conversion with physical...

  19. Sobre objetos y experiencias virtuales

    OpenAIRE

    Pacho, Julián

    2009-01-01

    This paper analyses basic onto-epistemological properties of the virtual reality and suggests these theses. First, the virtual reality establishes a new nature; its essential feature is to be an organic world of emancipated techno-theories. Second, the virtual reality doesn’t substitutes the traditional book; it substitutes the world. Third, the experience of the world in the virtual reality excludes the natural world experience. Fourth, the ontology of virtual reality is build without an act...

  20. Leader competencies in virtual organization

    OpenAIRE

    Bulinska-Stangrecka, Helena

    2018-01-01

    This paper discusses the competence required in the leadership of virtual organization. The specics of virtual organization presents a challenge to traditional managerial styles. In order to achieve success in virtual environment, a leader must develop specic abilities. This analysis examines the uniqueness of the virtual organization, including team work and management. The last part presents ndings and summaries regarding e€ective e-leadership requirement. A virtual leader ma...

  1. Borehole radar diffraction tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seong Jun; Kim, Jung Ho; Yi, Myeong Jong; Chung, Seung Hwan; Lee, Hee Il [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1997-12-01

    Tomography is widely used as imaging method for determining subsurface structure. Among the reconstruction algorithms for tomographic imaging, travel time tomography is almost applied to imaging subsurface. But isolated small body comparable with the wavelength could not be well recognized by travel time tomography. Other tomographic method are need to improve the imaging process. In the study of this year, diffraction tomography was investigated. The theory for diffraction tomography is based on the 1st-order Born approximation. Multisource holography, which is similar to Kirchihoff migration, is compared with diffraction tomography. To improve 1st-order Born diffraction tomography, two kinds of filter designed from multisource holography and 2-D green function, respectively, applied on the reconstructed image. The algorithm was tested for the numerical modeling data of which algorithm consists of the analytic computation of radar signal in transmitter and receiver regions and 2-D FDM scheme for the propagation of electromagnetic waves in media. The air-filled cavity model to show a typical diffraction pattern was applied to diffraction tomography imaging, and the result shows accurate location and area of cavity. But the calculated object function is not well matched the real object function, because the air-filled cavity model is not satisfied week scattered inhomogeneity for 1st born approximation, and the error term is included in estimating source wavelet from received signals. In spite of the object function error, the diffraction tomography assist for interpretation of subsurface as if conducted with travel time tomography. And the fracture model was tested, 1st born diffraction tomographic image is poor because of limited view angle coverage and violation of week scatter assumption, but the filtered image resolve the fracture somewhat better. The tested diffraction tomography image confirms effectiveness of filter for enhancing resolution. (author). 14

  2. Hybrid rendering of the chest and virtual bronchoscopy [corrected].

    Science.gov (United States)

    Seemann, M D; Seemann, O; Luboldt, W; Gebicke, K; Prime, G; Claussen, C D

    2000-10-30

    Thin-section spiral computed tomography was used to acquire the volume data sets of the thorax. The tracheobronchial system and pathological changes of the chest were visualized using a color-coded surface rendering method. The structures of interest were then superimposed on a volume rendering of the other thoracic structures, thus producing a hybrid rendering. The hybrid rendering technique exploit the advantages of both rendering methods and enable virtual bronchoscopic examinations using different representation models. Virtual bronchoscopic examinations with a transparent color-coded shaded-surface model enables the simultaneous visualization of both the airways and the adjacent structures behind of the tracheobronchial wall and therefore, offers a practical alternative to fiberoptic bronchoscopy. Hybrid rendering and virtual endoscopy obviate the need for time consuming detailed analysis and presentation of axial source images.

  3. Clinical applications of imaging reconstruction by virtual sonography

    International Nuclear Information System (INIS)

    Mori, Akihiro; Oohashi, Noritsugu; Maruyama, Takako; Tatebe, Hideharu; Fushimi, Nobutoshi; Asano, Takayuki; Inoue, Hiroshi; Okuno, Masataka

    2008-01-01

    One of the pitfalls in managing multiple liver tumors is the difficulty in identifying individual tumors on ultrasonography. Computed tomography (CT)-assisted virtual sonography has been shown to improve sonographic diagnosis, however it requires additional equipment and software. We have developed a simple reconstruction method of virtual sonography (SRVS). We reconstructed SRVS mimicking ultrasonographic images, utilizing a workstation software attached to a multi-detector row CT system without any additional program. We have performed SRVS in 32 patients with 41 liver tumors that could hardly be identify on ultrasonography. SRVS assisted the identification of malignant form non-pathologic ones and thereby contributed to the appropriate clinical strategy including radiofrequency ablation (RFA) (18 tumors), liver biopsy (2 tumors), other therapies (4 tumors) and follow-up (17 tumors). We have developed virtual sonography using conventional CT software. SRVS seems useful in the clinical practice in managing liver tumors. (author)

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  5. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  6. Gamma tomography apparatus

    International Nuclear Information System (INIS)

    Span, F.J.

    1988-01-01

    The patent concerns a gamma tomography apparatus for medical diagnosis. The apparatus comprises a gamma scintillation camera head and a suspension system for supporting and positioning the camera head with respect for the patient. Both total body scanning and single photon emission tomography can be carried out with the apparatus. (U.K.)

  7. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  8. Tomography of nonclassical states

    NARCIS (Netherlands)

    Bazrafkan, MR; Man'ko, [No Value

    2003-01-01

    A review of the symplectic tomography method is presented. Superpositions of different types of photon states are considered within the framework of the tomography approach. Such nonclassical photon states as even and odd coherent states, crystallized Schrodinger cat states, and other superposition

  9. Virtual data in CMS production

    International Nuclear Information System (INIS)

    Arbree, A. et al.

    2004-01-01

    Initial applications of the GriPhyN Chimera Virtual Data System have been performed within the context of CMS Production of Monte Carlo Simulated Data. The GriPhyN Chimera system consists of four primary components: (1) a Virtual Data Language, which is used to describe virtual data products, (2) a Virtual Data Catalog, which is used to store virtual data entries, (3) an Abstract Planner, which resolves all dependencies of a particular virtual data product and forms a location and existence independent plan, (4) a Concrete Planner, which maps an abstract, logical plan onto concrete, physical grid resources accounting for staging in/out files and publishing results to a replica location service. A CMS Workflow Planner, MCRunJob, is used to generate virtual data products using the Virtual Data Language. Subsequently, a prototype workflow manager, known as WorkRunner, is used to schedule the instantiation of virtual data products across a grid

  10. Virtual Data in CMS Production

    CERN Document Server

    Arbree, A; Bourilkov, D; Cavanaugh, R J; Graham, G; Katageri, S; Rodríguez, J; Voeckler, J; Wilde, M

    2003-01-01

    Initial applications of the GriPhyN Chimera Virtual Data System have been performed within the context of CMS Production of Monte Carlo Simulated Data. The GriPhyN Chimera system consists of four primary components: 1) a Virtual Data Language, which is used to describe virtual data products, 2) a Virtual Data Catalog, which is used to store virtual data entries, 3) an Abstract Planner, which resolves all dependencies of a particular virtual data product and forms a location and existence independent plan, 4) a Concrete Planner, which maps an abstract, logical plan onto concrete, physical grid resources accounting for staging in/out files and publishing results to a replica location service. A CMS Workflow Planner, MCRunJob, is used to generate virtual data products using the Virtual Data Language. Subsequently, a prototype workflow manager, known as WorkRunner, is used to schedule the instantiation of virtual data products across a grid.

  11. Trends in Virtualized User Environments

    Directory of Open Access Journals (Sweden)

    Diane Barrett

    2008-06-01

    Full Text Available Virtualized environments can make forensics investigation more difficult. Technological advances in virtualization tools essentially make removable media a PC that can be carried around in a pocket or around a neck. Running operating systems and applications this way leaves very little trace on the host system. This paper will explore all the newest methods for virtualized environments and the implications they have on the world of forensics. It will begin by describing and differentiating between software and hardware virtualization. It will then move on to explain the various methods used for server and desktop virtualization. Next, it will explain how virtualization affects the basic forensic process. Finally, it will describe the common methods to find virtualization artifacts and identify virtual activities that affect the examination process of certain virtualized user environments.

  12. Software for simulation of a computed tomography imaging spectrometer using optical design software

    Science.gov (United States)

    Spuhler, Peter T.; Willer, Mark R.; Volin, Curtis E.; Descour, Michael R.; Dereniak, Eustace L.

    2000-11-01

    Our Imaging Spectrometer Simulation Software known under the name Eikon should improve and speed up the design of a Computed Tomography Imaging Spectrometer (CTIS). Eikon uses existing raytracing software to simulate a virtual instrument. Eikon enables designers to virtually run through the design, calibration and data acquisition, saving significant cost and time when designing an instrument. We anticipate that Eikon simulations will improve future designs of CTIS by allowing engineers to explore more instrument options.

  13. Virtual Library: An essential component of virtual education

    Directory of Open Access Journals (Sweden)

    M zarghani

    2015-06-01

    Full Text Available Abstract Introduction: Library is one of the essential elements of universities which provide some important educational needs of students. Virtual education can not be exempted and virtual libraries are important support for virtual training programs. The purpose of this study is to evaluate the viewpoint of administrators and students in virtual education centers about the virtual library, its role and resources. Methods: This study was a descriptive survey. The research instrument was a researcher made questionnaire that its validity and reliability was confirmed. The study population consisted of 19 virtual training centers in Tehran city. Out of 19 centers, simple randomized sampling was done in five Centers. The sample size was 360 students. Data collection was conducted online and descriptive statistics using SPSS 18 and Excel software were used. Results: The results showed that viewpoints of administrators and students about the mission and services of virtual libraries in some cases were similar and in some cases were different. One of the administrators’ reasons for setting up a virtual learning system was lifelong learning, and lack of knowledge about virtual libraries was the reason for inadequate use of virtual libraries. The best format of virtual library from the administrators’ and students’ viewpoint, was portal document format (PDF. Conclusion: One of the most important function of a virtual library, is lifelong learning and empowering users to provide information and educational needs. The main reason for not setting up a virtual library is t lack of knowledge about it.

  14. Varieties of virtualization

    Science.gov (United States)

    Ellis, Stephen R.

    1991-01-01

    Natural environments have a content, i.e., the objects in them; a geometry, i.e., a pattern of rules for positioning and displacing the objects; and a dynamics, i.e., a system of rules describing the effects of forces acting on the objects. Human interaction with most common natural environments has been optimized by centuries of evolution. Virtual environments created through the human-computer interface similarly have a content, geometry, and dynamics, but the arbitrary character of the computer simulation creating them does not insure that human interaction with these virtual environments will be natural. The interaction, indeed, could be supernatural but it also could be impossible. An important determinant of the comprehensibility of a virtual environment is the correspondence between the environmental frames of reference and those associated with the control of environmental objects. The effects of rotation and displacement of control frames of reference with respect to corresponding environmental references differ depending upon whether perceptual judgement or manual tracking performance is measured. The perceptual effects of frame of reference displacement may be analyzed in terms of distortions in the process of virtualizing the synthetic environment space. The effects of frame of reference displacement and rotation have been studied by asking subjects to estimate exocentric direction in a virtual space.

  15. The virtual slice setup.

    Science.gov (United States)

    Lytton, William W; Neymotin, Samuel A; Hines, Michael L

    2008-06-30

    In an effort to design a simulation environment that is more similar to that of neurophysiology, we introduce a virtual slice setup in the NEURON simulator. The virtual slice setup runs continuously and permits parameter changes, including changes to synaptic weights and time course and to intrinsic cell properties. The virtual slice setup permits shocks to be applied at chosen locations and activity to be sampled intra- or extracellularly from chosen locations. By default, a summed population display is shown during a run to indicate the level of activity and no states are saved. Simulations can run for hours of model time, therefore it is not practical to save all of the state variables. These, in any case, are primarily of interest at discrete times when experiments are being run: the simulation can be stopped momentarily at such times to save activity patterns. The virtual slice setup maintains an automated notebook showing shocks and parameter changes as well as user comments. We demonstrate how interaction with a continuously running simulation encourages experimental prototyping and can suggest additional dynamical features such as ligand wash-in and wash-out-alternatives to typical instantaneous parameter change. The virtual slice setup currently uses event-driven cells and runs at approximately 2 min/h on a laptop.

  16. Aspects of pulmonary histiocytosis X on high resolution computed tomography

    International Nuclear Information System (INIS)

    Costa, N.S.S.; Castro Lessa Angela, M.T. de; Angelo Junior, J.R.L.; Silva, F.M.D.; Kavakama, J.; Carvalho, C.R.R. de; Cerri, G.G.

    1995-01-01

    Pulmonary histiocytosis X is a disease that occurs in young adults and presents with nodules and cysts, mainly in upper lobes, with consequent pulmonary fibrosis. These pulmonary changes are virtually pathognomonic findings on high resolution computed tomography, that allows estimate the area of the lung involved and distinguish histiocytosis X from other disorders that also produces nodules and cysts. (author). 10 refs, 2 tabs, 6 figs

  17. Tunable aqueous virtual micropore.

    Science.gov (United States)

    Park, Jae Hyun; Guan, Weihua; Reed, Mark A; Krstić, Predrag S

    2012-03-26

    A charged microparticle can be trapped in an aqueous environment by forming a narrow virtual pore--a cylindrical space region in which the particle motion in the radial direction is limited by forces emerging from dynamical interactions of the particle charge and dipole moment with an external radiofrequency quadrupole electric field. If the particle satisfies the trap stability criteria, its mean motion is reduced exponentially with time due to the viscosity of the aqueous environment; thereafter the long-time motion of particle is subject only to random, Brownian fluctuations, whose magnitude, influenced by the electrophoretic and dielectrophoretic effects and added to the particle size, determines the radius of the virtual pore, which is demonstrated by comparison of computer simulations and experiment. The measured size of the virtual nanopore could be utilized to estimate the charge of a trapped micro-object. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Material and Virtuality

    DEFF Research Database (Denmark)

    Kruse Aagaard, Anders

    2015-01-01

    Through tangible experiments this paper discusses the dialogues between digital architectural drawing and the process of materialisation. The paper sets op the spans between virtual and actual and control and uncertainty making these oppositions a combined spaces where information between a digital...... world and a physical world can interchange. The paper suggest an approach where an overlapping of virtuality and the tangible material output from digital fabrication machines create a method of using materialisation tools as instruments to connect the reality of materials and to an exploring process...... through these experiments is both tangible and directly connected to real actions in digital drawing or material processing but also the base for theoretical contemplations of the relation between virtual and actual and control and uncertainty....

  19. The Virtual Diphoton Excess

    CERN Document Server

    Stolarski, Daniel

    2016-01-01

    Interpreting the excesses around 750 GeV in the diphoton spectra to be the signal of a new heavy scalar decaying to photons, we point out the possibility of looking for correlated signals with virtual photons. In particular, we emphasize that the effective operator that generates the diphoton decay will also generate decays to two leptons and a photon, as well as to four leptons, independently of the new resonance couplings to $Z\\gamma$ and $ZZ$. Depending on the relative sizes of these effective couplings, we show that the virtual diphoton component can make up a sizable, and sometimes dominant, contribution to the total $2\\ell \\gamma$ and $4\\ell$ partial widths. We also discuss modifications to current experimental cuts in order to maximize the sensitivity to these virtual photon effects. Finally, we briefly comment on prospects for channels involving other Standard Model fermions as well as more exotic decay possibilities of the putative resonance.

  20. First Indico Virtual Event

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    The first Indico virtual event will take place on February 4th 15:00 and will focus on two main topics The release of Indico v1.2 The migration of the OO Indico backend database (ZODB) to a more standard DBMS It will be fully virtual using the CERN Vidyo service and will foster discussions between developers and administrators of Indico servers worldwide. Connections to the virtual room will be open, but attendees are encouraged to register to the event, in order to be informed of any changes in the organisation if any. If you would like to add a topic of discussion or propose yourself a contribution, please let us know at indico-team@cern.ch. Connection to Vidyo Vidyo connection details are available here CERN Vidyo service documentation can be found here First-time users are encouraged to try the service before connecting to the real event

  1. Virtual-World Naturalism

    Directory of Open Access Journals (Sweden)

    Daniel Reynolds

    2010-07-01

    Full Text Available Sometimes a player will stray from the path described by a game, moving into new spaces, developing new possible modes of interaction, and often discovering the rougher edges of the game world, where physics models break down, textures become incongruous, and the pieces don’t quite fit together. Gameplay that seeks out these spaces and these phenomena, that searches for such clues to the underlying construction of the virtual environment, is a kind of virtual-world naturalism, at once a return to an investigative urge that has been subsumed to the exhaustive mapping and description of the real world and a form of resistance to the very idea of pre-defined paths of action, of externally imposed limits, in virtual worlds as well as in our own.

  2. Applied virtual reality

    International Nuclear Information System (INIS)

    Yule, I.Y.; Lee, D.J.

    1996-01-01

    To reduce plant down time during irradiated fuel cell dismantling at Torness Power Station, a new visualisation technique has been used for the manipulator. Complex computer graphics packages were used to provide a ''Virtual Reality'' environment which allowed the Irradiated Fuel Dismantling Cell to be simulated. Significant cost savings have been achieved due to reductions in lost output. The virtual reality environment is at present being extended to the design and deployment of a new manipulator for in-vessel inspection of the boiler. (UK)

  3. Virtual interface environment workstations

    Science.gov (United States)

    Fisher, S. S.; Wenzel, E. M.; Coler, C.; Mcgreevy, M. W.

    1988-01-01

    A head-mounted, wide-angle, stereoscopic display system controlled by operator position, voice and gesture has been developed at NASA's Ames Research Center for use as a multipurpose interface environment. This Virtual Interface Environment Workstation (VIEW) system provides a multisensory, interactive display environment in which a user can virtually explore a 360-degree synthesized or remotely sensed environment and can viscerally interact with its components. Primary applications of the system are in telerobotics, management of large-scale integrated information systems, and human factors research. System configuration, research scenarios, and research directions are described.

  4. Virtual reality haptic dissection.

    Science.gov (United States)

    Erolin, Caroline; Wilkinson, Caroline; Soames, Roger

    2011-12-01

    This project aims to create a three-dimensional digital model of the human hand and wrist which can be virtually 'dissected' through a haptic interface. Tissue properties will be added to the various anatomical structures to replicate a realistic look and feel. The project will explore the role of the medical artist, and investigate cross-discipline collaborations in the field of virtual anatomy. The software will be used to train anatomy students in dissection skills, before experience on a real cadaver. The effectiveness of the software will be evaluated and assessed both quantitatively as well as qualitatively.

  5. Virtual realities and education

    Directory of Open Access Journals (Sweden)

    Curcio Igor D.D.

    2016-12-01

    Full Text Available The purpose of this article is to highlight the state of the art of virtual reality, augmented reality, mixed reality technologies and their applications in formal education. We also present a selected list of case studies that prove the utility of these technologies in the context of formal education. Furthermore, as byproduct, the mentioned case studies show also that, although the industry is able to develop very advanced virtual environment technologies, their pedagogical implications are strongly related to a well-designed theoretical framework.

  6. Virtual power plant auctions

    International Nuclear Information System (INIS)

    Ausubel, Lawrence M.; Cramton, Peter

    2010-01-01

    Since their advent in 2001, virtual power plant (VPP) auctions have been implemented widely. In this paper, we describe the simultaneous ascending-clock auction format that has been used for virtually all VPP auctions to date, elaborating on other design choices that most VPP auctions have had in common as well as discussing a few aspects that have varied significantly among VPP auctions. We then evaluate the various objectives of regulators in requiring VPP auctions, concluding that the auctions have been effective devices for facilitating new entry into electricity markets and for developing wholesale power markets. (author)

  7. Virtual power plant auctions

    Energy Technology Data Exchange (ETDEWEB)

    Ausubel, Lawrence M.; Cramton, Peter [Department of Economics, University of Maryland, College Park, MD 20742 (United States)

    2010-12-15

    Since their advent in 2001, virtual power plant (VPP) auctions have been implemented widely. In this paper, we describe the simultaneous ascending-clock auction format that has been used for virtually all VPP auctions to date, elaborating on other design choices that most VPP auctions have had in common as well as discussing a few aspects that have varied significantly among VPP auctions. We then evaluate the various objectives of regulators in requiring VPP auctions, concluding that the auctions have been effective devices for facilitating new entry into electricity markets and for developing wholesale power markets. (author)

  8. Virtual water: Virtuous impact? : the unsteady state of virtual water

    NARCIS (Netherlands)

    Roth, D.; Warner, J.F.

    2008-01-01

    Virtual water,” water needed for crop production, is now being mainstreamed in the water policy world. Relying on virtual water in the form of food imports is increasingly recommended as good policy for water-scarce areas. Virtual water globalizes discussions on water scarcity, ecological

  9. Computerised Axial Tomography (CAT)

    Science.gov (United States)

    1990-06-01

    Ministry of’ Defence, Defence Research Information Centre, UK. Computerised Axial Tomography ( CAT ) Report Secufty C"uMiauion tide Onadtiicadon (U. R, Cor S...DRIC T 8485 COMPUTERISED AXIAL TOMOGRAPHY ( CAT ) F.P. GENTILE, F. SABETTA, V. TRO1* ISS R 78/4.Rome, 1.5 Mlarch 1978 (from Italian) B Distribution(f...dello Radiazioni ISSN 0390--6477 F.P. GENTILE, F. SABETTA. V. TROI Computerised Axial Tomography ( CAT ) March 15, 1978). This paper is a review of

  10. Quantification in emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-11-01

    The objective of this lecture is to understand the possibilities and limitations of the quantitative analysis of single photon emission computed tomography (SPECT) and positron emission tomography (PET) images. It is also to identify the conditions to be fulfilled to obtain reliable quantitative measurements from images. Content: 1 - Introduction: Quantification in emission tomography - definition and challenges; quantification biasing phenomena 2 - Main problems impacting quantification in PET and SPECT: problems, consequences, correction methods, results (Attenuation, scattering, partial volume effect, movement, un-stationary spatial resolution in SPECT, fortuitous coincidences in PET, standardisation in PET); 3 - Synthesis: accessible efficiency, know-how, Precautions, beyond the activity measurement

  11. Positron emission tomography

    International Nuclear Information System (INIS)

    Wienhard, K.; Heiss, W.D.

    1984-01-01

    The principles and selected clinical applications of positron emission tomography are described. In this technique a chemical compound is labeled with a positron emitting isotope and its biochemical pathway is traced by coincidence detection of the two annihilation photons. The application of the techniques of computed tomography allows to reconstruct the spatial distribution of the radioactivity within a subject. The 18 F-deoxyglucose method for quantitative measurement of local glucose metabolism is discussed in order to illustrate the possibilities of positron emission tomography to record physiological processes in vivo. (orig.) [de

  12. Virtual Library Design Document; TOPICAL

    International Nuclear Information System (INIS)

    M. A. deLamare

    2001-01-01

    The objective of this document is to establish a design for the virtual library user and administrative layers that complies with the requirements of the virtual library software specification and subordinate module specification

  13. Universidades virtuales: ¿aprendizaje real?

    OpenAIRE

    Valenzuela González, Jaime R.

    2015-01-01

    1. Introducción; 2. Modalidades educativas; 3. Concepto y características de las universidades virtuales; 4. Un modelo de universidad virtual; 5. Universidades virtuales ¿aprendizaje real?; 6. Tensiones de las universidades virtuales; 7. Referencias

  14. Corporate Training in Virtual Worlds

    Directory of Open Access Journals (Sweden)

    Charles Nebolsky

    2004-12-01

    Full Text Available This paper presents virtual training worlds that are relatively low-cost distributed collaborative learning environments suitable for corporate training. A virtual training world allows a facilitator, experts and trainees communicating and acting in the virtual environment for practicing skills during collaborative problem solving. Using these environments is beneficial to both trainees and corporations. Two system prototypes – the sales training and the leadership training virtual worlds – are described. The leadership training course design is discussed in details.

  15. Virtual reality for employability skills

    OpenAIRE

    Minocha, Shailey; Tudor, Ana-Despina

    2017-01-01

    We showed a variety of virtual reality technologies, and through examples, we discussed how virtual reality technology is transforming work styles and workplaces. Virtual reality is becoming pervasive in almost all domains starting from arts, environmental causes to medical education and disaster management training, and to supporting patients with Dementia. Thus, an awareness of the virtual reality technology and its integration in curriculum design will provide and enhance employability ski...

  16. Three-dimensional treatment planning of orthognathic surgery in the era of virtual imaging.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mollemans, W.; Schutyser, F.A.C.

    2009-01-01

    PURPOSE: The aim of this report was to present an integrated 3-dimensional (3D) virtual approach toward cone-beam computed tomography-based treatment planning of orthognathic surgery in the clinical routine. MATERIALS AND METHODS: We have described the different stages of the workflow process for

  17. Conventional versus virtual radiographs of the injured pelvis and acetabulum

    Energy Technology Data Exchange (ETDEWEB)

    Bishop, Julius A.; Rao, Allison J.; Pouliot, Michael A.; Bellino, Michael [Stanford University School of Medicine, Department of Orthopaedic Surgery, Stanford, CA (United States); Beaulieu, Christopher [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2015-09-15

    Evaluation of the fractured pelvis or acetabulum requires both standard radiographic evaluation as well as computed tomography (CT) imaging. The standard anterior-posterior (AP), Judet, and inlet and outlet views can now be simulated using data acquired during CT, decreasing patient discomfort, radiation exposure, and cost to the healthcare system. The purpose of this study is to compare the image quality of conventional radiographic views of the traumatized pelvis to virtual radiographs created from pelvic CT scans. Five patients with acetabular fractures and ten patients with pelvic ring injuries were identified using the orthopedic trauma database at our institution. These fractures were evaluated with both conventional radiographs as well as virtual radiographs generated from a CT scan. A web-based survey was created to query overall image quality and visibility of relevant anatomic structures. This survey was then administered to members of the Orthopaedic Trauma Association (OTA). Ninety-seven surgeons completed the acetabular fracture survey and 87 completed the pelvic fracture survey. Overall image quality was judged to be statistically superior for the virtual as compared to conventional images for acetabular fractures (3.15 vs. 2.98, p = 0.02), as well as pelvic ring injuries (2.21 vs. 1.45, p = 0.0001). Visibility ratings for each anatomic landmark were statistically superior with virtual images as well. Virtual radiographs of pelvic and acetabular fractures offer superior image quality, improved comfort, decreased radiation exposure, and a more cost-effective alternative to conventional radiographs. (orig.)

  18. Virtual manufacturing in reality

    Science.gov (United States)

    Papstel, Jyri; Saks, Alo

    2000-10-01

    SMEs play an important role in manufacturing industry. But from time to time there is a shortage in resources to complete the particular order in time. Number of systems is introduced to produce digital information in order to support product and process development activities. Main problem is lack of opportunity for direct data transition within design system modules when needed temporary extension of design capacity (virtuality) or to implement integrated concurrent product development principles. The planning experience in the field is weakly used as well. The concept of virtual manufacturing is a supporting idea to solve this problem. At the same time a number of practical problems should be solved like information conformity, data transfer, unified technological concepts acceptation etc. In the present paper the proposed ways to solve the practical problems of virtual manufacturing are described. General objective is to introduce the knowledge-based CAPP system as missing module for Virtual Manufacturing in the selected product domain. Surface-centered planning concept based on STEP- based modeling principles, and knowledge-based process planning methodology will be used to gain the objectives. As a result the planning module supplied by design data with direct access, and supporting advising environment is expected. Mould producing SME would be as test basis.

  19. Virtual First Impressions

    Science.gov (United States)

    Bergren, Martha Dewey

    2005-01-01

    Frequently, a nurse's first and only contact with a graduate school, legislator, public health official, professional organization, or school nursing colleague is made through e-mail. The format, the content, and the appearance of the e-mail create a virtual first impression. Nurses can manage their image and the image of the profession by…

  20. Virtual Libraries: Service Realities.

    Science.gov (United States)

    Novak, Jan

    This paper discusses client service issues to be considered when transitioning to a virtual library situation. Themes related to the transitional nature of society in the knowledge era are presented, including: paradox and a contradictory nature; blurring of boundaries; networks, systems, and holistic thinking; process/not product, becoming/not…

  1. Virtual Bridge Design Challenge

    Science.gov (United States)

    Mitts, Charles R.

    2013-01-01

    This design/problem-solving activity challenges students to design a replacement bridge for one that has been designated as either structurally deficient or functionally obsolete. The Aycock MS Technology/STEM Magnet Program Virtual Bridge Design Challenge is an authentic introduction to the engineering design process. It is a socially relevant…

  2. Virtual Environments 2005

    DEFF Research Database (Denmark)

    This book contains the proceedings of the joint 9th International Immersive Projection Technologies Workshop and the 11th EUROGRAPHICS Virtual Environments Workshop (IPTEGVE). The event was held in Aalborg, Denmark the 6. and 7. October 2005. It was organized at the VR Media Lab, Aalborg University...

  3. Virtual machine performance benchmarking.

    Science.gov (United States)

    Langer, Steve G; French, Todd

    2011-10-01

    The attractions of virtual computing are many: reduced costs, reduced resources and simplified maintenance. Any one of these would be compelling for a medical imaging professional attempting to support a complex practice on limited resources in an era of ever tightened reimbursement. In particular, the ability to run multiple operating systems optimized for different tasks (computational image processing on Linux versus office tasks on Microsoft operating systems) on a single physical machine is compelling. However, there are also potential drawbacks. High performance requirements need to be carefully considered if they are to be executed in an environment where the running software has to execute through multiple layers of device drivers before reaching the real disk or network interface. Our lab has attempted to gain insight into the impact of virtualization on performance by benchmarking the following metrics on both physical and virtual platforms: local memory and disk bandwidth, network bandwidth, and integer and floating point performance. The virtual performance metrics are compared to baseline performance on "bare metal." The results are complex, and indeed somewhat surprising.

  4. Virtual Interactive Space (VIS)

    DEFF Research Database (Denmark)

    Brooks, Anthony Lewis

    2015-01-01

    This paper shares code that enables the making of a Virtual Interactive Space (VIS) where the skin of the invisible active sensor area is dynamically responsive to the velocity of a limb e.g. hand. Used in proprioception training of movement the patch is at the core of the author’s Reafferentation...

  5. A virtual nuclear world?

    International Nuclear Information System (INIS)

    Salve, R.

    1998-01-01

    The way in which virtual reality technology has so dramatically developed over the last few years has opened up the possibility of its application to various industrial processes. This article describes the possible uses of such a technique in nuclear power plants in various phases such as design, construction, operation or dismantling. (Author)

  6. Virtual Libraries: Service Realities.

    Science.gov (United States)

    Novak, Jan

    2002-01-01

    Discussion of changes in society that have resulted from information and communication technologies focuses on changes in libraries and a new market for library services with new styles of clients. Highlights client service issues to be considered when transitioning to a virtual library situation. (Author/LRW)

  7. The Virtual Library

    Science.gov (United States)

    Valenza, Joyce Kasman

    2006-01-01

    Today's school libraries must meet student needs as both a physical and virtual space. Existing both offline and online, they must offer around-the-clock access as well as instruction and guidance that support the face-to-face interactions of students with librarians and classroom teachers. Although students are often technologically proficient,…

  8. Virtual Reality Hysteroscopy

    Science.gov (United States)

    Levy

    1996-08-01

    New interactive computer technologies are having a significant influence on medical education, training, and practice. The newest innovation in computer technology, virtual reality, allows an individual to be immersed in a dynamic computer-generated, three-dimensional environment and can provide realistic simulations of surgical procedures. A new virtual reality hysteroscope passes through a sensing device that synchronizes movements with a three-dimensional model of a uterus. Force feedback is incorporated into this model, so the user actually experiences the collision of an instrument against the uterine wall or the sensation of the resistance or drag of a resectoscope as it cuts through a myoma in a virtual environment. A variety of intrauterine pathologies and procedures are simulated, including hyperplasia, cancer, resection of a uterine septum, polyp, or myoma, and endometrial ablation. This technology will be incorporated into comprehensive training programs that will objectively assess hand-eye coordination and procedural skills. It is possible that by incorporating virtual reality into hysteroscopic training programs, a decrease in the learning curve and the number of complications presently associated with the procedures may be realized. Prospective studies are required to assess these potential benefits.

  9. Adapting Virtual Camera Behaviour

    DEFF Research Database (Denmark)

    Burelli, Paolo

    2013-01-01

    In a three-dimensional virtual environment aspects such as narrative and interaction completely depend on the camera since the camera defines the player’s point of view. Most research works in automatic camera control aim to take the control of this aspect from the player to automatically gen- er...

  10. Virtual digital library

    Science.gov (United States)

    Thoma, George R.

    1996-03-01

    The virtual digital library, a concept that is quickly becoming a reality, offers rapid and geography-independent access to stores of text, images, graphics, motion video and other datatypes. Furthermore, a user may move from one information source to another through hypertext linkages. The projects described here further the notion of such an information paradigm from an end user viewpoint.

  11. Definition of Virtual Levels.

    Science.gov (United States)

    Shore, Bruce W.

    1979-01-01

    Presents an examination of graphical displays of solutions to time-dependent Schrodinger equation modeling a laser-excited three-level atom. It suggests that an energy level may be regarded as virtual when it is detuned from resonance by more than two Rabi frequencies. (Author/HM)

  12. The Virtual Classroom.

    Science.gov (United States)

    Roach, Ronald

    1997-01-01

    Increasingly, college teachers and instructional designers are exploring use of the technology of virtual reality to enhance student learning in math, science, and the social sciences. It is found particularly useful for teaching psychomotor skills and may have potential to make scientific concepts and abstract subjects more accessible to…

  13. File System Virtual Appliances

    Science.gov (United States)

    2010-05-01

    4 KB of data is read or written, data is copied back and forth using trampoline buffers — pages that are shared during proxy initialization — because...in 2008. CIO Magazine. 104 · File system virtual appliances [64] Megiddo, N. and Modha, D. S. 2003. ARC: A Self-Tuning, Low Over- head Replacement

  14. Virtual Beach Manager Toolset

    Science.gov (United States)

    The Virtual Beach Manager Toolset (VB) is a set of decision support software tools developed to help local beach managers make decisions as to when beaches should be closed due to predicted high levels of water borne pathogens. The tools are being developed under the umbrella of...

  15. Virtual Reality and Education.

    Science.gov (United States)

    Helsel, Sandra

    1992-01-01

    Intended to provide a basic understanding of virtual reality (VR) from an educational perspective, this article describes the debate between conceptual and technological orientations to VR; the conceptual orientation to VR; technological definitions of VR, artificial reality, and cyberspace; dimensions of VR; and VR's impact on education. (11…

  16. Virtual Reality in the Classroom.

    Science.gov (United States)

    Pantelidis, Veronica S.

    1993-01-01

    Considers the concept of virtual reality; reviews its history; describes general uses of virtual reality, including entertainment, medicine, and design applications; discusses classroom uses of virtual reality, including a software program called Virtus WalkThrough for use with a computer monitor; and suggests future possibilities. (34 references)…

  17. Interacting with a Virtual Conductor

    NARCIS (Netherlands)

    Bos, Pieter; Reidsma, Dennis; Ruttkay, Zsófia; Nijholt, Anton; Harper, Richard; Rauterberg, Matthias; Combetto, Marco

    This paper presents a virtual embodied agent that can conduct musicians in a live performance. The virtual conductor conducts music specified by a MIDI file and uses input from a microphone to react to the tempo of the musicians. The current implementation of the virtual conductor can interact with

  18. Ethnography in a Virtual World

    Science.gov (United States)

    Shumar, Wesley; Madison, Nora

    2013-01-01

    This article situates the discussion of virtual ethnography within the larger political/economic changes of twenty-first century consumer capitalism and suggests that increasingly our entire social world is a virtual world and that there were very particular utopian and dystopian framings of virtual community growing out of that history. The…

  19. Virtual reality in pediatric psychology

    OpenAIRE

    Parsons, T. D.; Riva, G.; Parsons, S. J.; Mantovani, F.; Newbutt, N.; Lin, L.; Venturini, E.; Hall, T.

    2017-01-01

    Virtual reality technologies allow for controlled simulations of affectively engaging background narratives. These virtual environments offer promise for enhancing emotionally relevant experiences and social interactions. Within this context virtual reality can allow instructors, therapists, neuropsychologists, and service providers to offer safe, repeatable, and diversifiable interventions that can benefit assessments and learning in both typically developing children and children with disab...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  2. Cardiac positron emission tomography

    International Nuclear Information System (INIS)

    Eftekhari, M.; Ejmalian, G.

    2003-01-01

    Positron emission tomography is an intrinsically tool that provide a unique and unparalleled approach for clinicians and researchers to interrogate the heart noninvasively. The ability to label substances of physiological interest with positron-emitting radioisotopes has permitted insight into normal blood flow and metabolism and the alterations that occur with disease states. Positron emission tomography of the heart has evolved as a unique, noninvasive approach for the assessment of myocardial perfusion, metabolism, and function. Because of the intrinsic quantitative nature of positron emission tomography measurements as well as the diverse compounds that can be labeled with positron- emitting radioisotopes, studies with positron emission tomography have provided rich insight into the physiology of the heart under diverse conditions

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  4. Positron emission tomography

    International Nuclear Information System (INIS)

    Iio, Masahiro

    1982-01-01

    Utilization of positron emission tomography was reviewed in relation to construction and planned construction of small-size medical cyclotrons, planned construction of positron cameras and utilization of short-lived radionuclides. (Chiba, N.)

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for ... Tomography (CT) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head and Neck Cancer top ... Tomography (CT) - Sinuses Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... of the Sinuses? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  13. Intracoronary optical coherence tomography

    DEFF Research Database (Denmark)

    Tenekecioglu, Erhan; Albuquerque, Felipe N; Sotomi, Yohei

    2017-01-01

    By providing valuable information about the coronary artery wall and lumen, intravascular imaging may aid in optimizing interventional procedure results and thereby could improve clinical outcomes following percutaneous coronary intervention (PCI). Intravascular optical coherence tomography (OCT...

  14. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  15. Tomography in nuclear medicine

    International Nuclear Information System (INIS)

    Levi de Cabrejas, Mariana

    1999-01-01

    This book is a contribution to the training and diffusion of the tomography method image diagnosis in nuclear medicine, which principal purpose is the information to professionals and technical personnel, specially for the spanish speaking staff

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the ...

  19. Electrical Impedance Tomography Technology

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal for the Electrical Impedance Tomography Technology (EITT) project is to develop a reliable portable, lightweight device providing two-dimensional...

  20. Virtual Sensor Test Instrumentation

    Science.gov (United States)

    Wang, Roy

    2011-01-01

    Virtual Sensor Test Instrumentation is based on the concept of smart sensor technology for testing with intelligence needed to perform sell-diagnosis of health, and to participate in a hierarchy of health determination at sensor, process, and system levels. A virtual sensor test instrumentation consists of five elements: (1) a common sensor interface, (2) microprocessor, (3) wireless interface, (4) signal conditioning and ADC/DAC (analog-to-digital conversion/ digital-to-analog conversion), and (5) onboard EEPROM (electrically erasable programmable read-only memory) for metadata storage and executable software to create powerful, scalable, reconfigurable, and reliable embedded and distributed test instruments. In order to maximize the efficient data conversion through the smart sensor node, plug-and-play functionality is required to interface with traditional sensors to enhance their identity and capabilities for data processing and communications. Virtual sensor test instrumentation can be accessible wirelessly via a Network Capable Application Processor (NCAP) or a Smart Transducer Interlace Module (STIM) that may be managed under real-time rule engines for mission-critical applications. The transducer senses the physical quantity being measured and converts it into an electrical signal. The signal is fed to an A/D converter, and is ready for use by the processor to execute functional transformation based on the sensor characteristics stored in a Transducer Electronic Data Sheet (TEDS). Virtual sensor test instrumentation is built upon an open-system architecture with standardized protocol modules/stacks to interface with industry standards and commonly used software. One major benefit for deploying the virtual sensor test instrumentation is the ability, through a plug-and-play common interface, to convert raw sensor data in either analog or digital form, to an IEEE 1451 standard-based smart sensor, which has instructions to program sensors for a wide variety of

  1. Reconfigurable virtual electrowetting channels.

    Science.gov (United States)

    Banerjee, Ananda; Kreit, Eric; Liu, Yuguang; Heikenfeld, Jason; Papautsky, Ian

    2012-02-21

    Lab-on-a-chip systems rely on several microfluidic paradigms. The first uses a fixed layout of continuous microfluidic channels. Such lab-on-a-chip systems are almost always application specific and far from a true "laboratory." The second involves electrowetting droplet movement (digital microfluidics), and allows two-dimensional computer control of fluidic transport and mixing. The merging of the two paradigms in the form of programmable electrowetting channels takes advantage of both the "continuous" functionality of rigid channels based on which a large number of applications have been developed to date and the "programmable" functionality of digital microfluidics that permits electrical control of on-chip functions. In this work, we demonstrate for the first time programmable formation of virtual microfluidic channels and their continuous operation with pressure driven flows using an electrowetting platform. Experimental, theoretical, and numerical analyses of virtual channel formation with biologically relevant electrolyte solutions and electrically-programmable reconfiguration are presented. We demonstrate that the "wall-less" virtual channels can be formed reliably and rapidly, with propagation rates of 3.5-3.8 mm s(-1). Pressure driven transport in these virtual channels at flow rates up to 100 μL min(-1) is achievable without distortion of the channel shape. We further demonstrate that these virtual channels can be switched on-demand between multiple inputs and outputs. Ultimately, we envision a platform that would provide rapid prototyping of microfluidic concepts and would be capable of a vast library of functions and benefitting applications from clinical diagnostics in resource-limited environments to rapid system prototyping to high throughput pharmaceutical applications.

  2. Reduced iodinated contrast media for abdominal imaging by dual-layer spectral detector computed tomography for patients with kidney disease

    Directory of Open Access Journals (Sweden)

    Hirokazu Saito, MD

    2018-04-01

    Full Text Available Contrast-enhanced computed tomography using iodinated contrast media is useful for diagnosis of gastrointestinal diseases. However, contrast-induced nephropathy remains problematic for kidney diseases patients. Although current guidelines recommended the use of a minimal dose of contrast media necessary to obtain adequate images for diagnosis, obtaining adequate images with sufficient contrast enhancement is difficult with conventional computed tomography using reduced contrast media. Dual-layer spectral detector computed tomography enables the simultaneous acquisition of low- and high-energy data and the reconstruction of virtual monochromatic images ranging from 40 to 200 keV, retrospectively. Low-energy virtual monochromatic images can enhance the contrast of images, thereby facilitating reduced contrast media. In case 1, abdominal computed tomography angiography at 50 keV using 40% of the conventional dose of contrast media revealed the artery that was the source of diverticular bleeding in the ascending colon. In case 2, ischemia of the transverse colon was diagnosed by contrast-enhanced computed tomography and iodine-selective imaging using 40% of the conventional dose of contrast media. In case 3, advanced esophagogastric junctional cancer was staged and preoperative abdominal computed tomography angiography could be obtained with 30% of the conventional dose of contrast media. However, the texture of virtual monochromatic images may be a limitation at low energy. Keywords: Virtual monochromatic images, Contrast-induced nephropathy

  3. Introduction to Seismic Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, Charlotte Anne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-21

    Tomography is a method of obtaining an image of a 3d object by observing the behavior of energy transmissions through the object. The image is obtained by Interrogating the object with Energy sources at a variety of Locations and observing the Object’s effects on the energy at a Variety of sensors. Tomography was first Used to build 3-dimensional Scans through Human bodies. These Are called computed Tomographic (ct) scans.

  4. Positron emission tomography

    International Nuclear Information System (INIS)

    Dvorak, O.

    1989-01-01

    The principle is briefly described of positron emission tomography, and its benefits and constraints are listed. It is emphasized that positron emission tomography (PET) provides valuable information on metabolic changes in the organism that are otherwise only very difficult to obtain, such as brain diagnosis including relationships between mental disorders and the physiology and pathophysiology of the brain. A PET machine is to be installed in Czechoslovakia in the near future. (L.O.)

  5. Art in virtual reality 2010

    Science.gov (United States)

    Chang, Ben

    2010-01-01

    For decades, virtual reality artwork has existed in a small but highly influential niche in the world of electronic and new media art. Since the early 1990's, virtual reality installations have come to define an extreme boundary point of both aesthetic experience and technological sophistication. Classic virtual reality artworks have an almost mythological stature - powerful, exotic, and often rarely exhibited. Today, art in virtual environments continues to evolve and mature, encompassing everything from fully immersive CAVE experiences to performance art in Second Life to the use of augmented and mixed reality in public space. Art in Virtual Reality 2010 is a public exhibition of new artwork that showcases the diverse ways that contemporary artists use virtual environments to explore new aesthetic ground and investigate the continually evolving relationship between our selves and our virtual worlds.

  6. Virtual Class Support at the Virtual Machine Level

    DEFF Research Database (Denmark)

    Nielsen, Anders Bach; Ernst, Erik

    2009-01-01

    This paper describes how virtual classes can be supported in a virtual machine.  Main-stream virtual machines such as the Java Virtual Machine and the .NET platform dominate the world today, and many languages are being executed on these virtual machines even though their embodied design choices...... conflict with the design choices of the virtual machine.  For instance, there is a non-trivial mismatch between the main-stream virtual machines mentioned above and dynamically typed languages.  One language concept that creates an even greater mismatch is virtual classes, in particular because fully...... general support for virtual classes requires generation of new classes at run-time by mixin composition.  Languages like CaesarJ and ObjectTeams can express virtual classes restricted to the subset that does not require run-time generation of classes, because of the restrictions imposed by the Java...

  7. Innovative application of virtual display technique in virtual museum

    Science.gov (United States)

    Zhang, Jiankang

    2017-09-01

    Virtual museum refers to display and simulate the functions of real museum on the Internet in the form of 3 Dimensions virtual reality by applying interactive programs. Based on Virtual Reality Modeling Language, virtual museum building and its effective interaction with the offline museum lie in making full use of 3 Dimensions panorama technique, virtual reality technique and augmented reality technique, and innovatively taking advantages of dynamic environment modeling technique, real-time 3 Dimensions graphics generating technique, system integration technique and other key virtual reality techniques to make sure the overall design of virtual museum.3 Dimensions panorama technique, also known as panoramic photography or virtual reality, is a technique based on static images of the reality. Virtual reality technique is a kind of computer simulation system which can create and experience the interactive 3 Dimensions dynamic visual world. Augmented reality, also known as mixed reality, is a technique which simulates and mixes the information (visual, sound, taste, touch, etc.) that is difficult for human to experience in reality. These technologies make virtual museum come true. It will not only bring better experience and convenience to the public, but also be conducive to improve the influence and cultural functions of the real museum.

  8. The Herbert Virtual Museum

    Directory of Open Access Journals (Sweden)

    Panagiotis Petridis

    2013-01-01

    Full Text Available In recent years, virtual reality and augmented reality have emerged as areas of extreme interest as unique methods for visualising and interacting with digital museum artefacts in a different context, for example, as a virtual museum or exhibition, particularly over the Internet. Modern cultural heritage exhibitions have evolved from static to dynamic exhibitions and challenging explorations. This paper presents two different applications developed for the Herbert Museum and Art Gallery that make the user’s experience more immersive, engaging, and interactive. The first application utilizes mobile phone devices in order to enrich the visitors experience in the museum, and the second application is a serious game for cultural heritage and in particular for museum environments focusing on the younger visitors.

  9. Curating Virtual Data Collections

    Science.gov (United States)

    Lynnes, Chris; Leon, Amanda; Ramapriyan, Hampapuram; Tsontos, Vardis; Shie, Chung-Lin; Liu, Zhong

    2015-01-01

    NASAs Earth Observing System Data and Information System (EOSDIS) contains a rich set of datasets and related services throughout its many elements. As a result, locating all the EOSDIS data and related resources relevant to particular science theme can be daunting. This is largely because EOSDIS data's organizing principle is affected more by the way they are produced than around the expected end use. Virtual collections oriented around science themes can overcome this by presenting collections of data and related resources that are organized around the user's interest, not around the way the data were produced. Virtual collections consist of annotated web addresses (URLs) that point to data and related resource addresses, thus avoiding the need to copy all of the relevant data to a single place. These URL addresses can be consumed by a variety of clients, ranging from basic URL downloaders (wget, curl) and web browsers to sophisticated data analysis programs such as the Integrated Data Viewer.

  10. Interactive Virtual Cinematography

    DEFF Research Database (Denmark)

    Burelli, Paolo

    is the process of visualising the content of a virtual environment by positioning and animating the virtual camera in the context of interactive applications such as a computer game. Camera placement and animation in games are usually directly controlled by the player or statically predened by designers. Direct...... control of the camera by the player increases the complexity of the interaction and reduces the designer's control on game storytelling. A completely designer-driven camera releases the player from the burden of controlling the point of view, but might generate undesired camera behaviours. Furthermore......, if the content of the game is procedurally generated, the designer might not have the necessary information to dene a priori the camera positions and movements. Automatic camera control aims to dene an abstraction layer that permits to control the camera using high-level and environment-independent rules...

  11. Virtual reality at work

    Science.gov (United States)

    Brooks, Frederick P., Jr.

    1991-01-01

    The utility of virtual reality computer graphics in telepresence applications is not hard to grasp and promises to be great. When the virtual world is entirely synthetic, as opposed to real but remote, the utility is harder to establish. Vehicle simulators for aircraft, vessels, and motor vehicles are proving their worth every day. Entertainment applications such as Disney World's StarTours are technologically elegant, good fun, and economically viable. Nevertheless, some of us have no real desire to spend our lifework serving the entertainment craze of our sick culture; we want to see this exciting technology put to work in medicine and science. The topics covered include the following: testing a force display for scientific visualization -- molecular docking; and testing a head-mounted display for scientific and medical visualization.

  12. Cuenca, realidad virtual

    Directory of Open Access Journals (Sweden)

    Concepción Rodríguez Ruza

    2012-11-01

    Full Text Available This project, Cuenca, realidad virtual, was created so that the key periods of the historical evolution of Cuenca could be explained, where the Islamic Cuenca, Christian Cuenca and Cuenca in the 18th Century are comprised. The reconstruction of these different ages is represented by different routes through a threedimensional environment by means of this application .In order to be put into practice, 3D geometries, 3D polygon models, texturin, 3D illumination and threedimensional geometries animation of all of these elements have been implemented. Virtual visits are introduced by some texts, hearings, plans, archive and current pictures. These routes allow the visitor to get to know the past of this town through a recreational and easy going method

  13. Applied virtual reality

    International Nuclear Information System (INIS)

    Yule, I.Y.; Lee, D.J.

    1996-01-01

    An early experience in deploying a manipulator to the Irradiated Fuel Dismantling Cell at Torness Power Station, quickly highlighted that special visualisation techniques were required to achieve a successful deployment and reduce plant system down time. This visualisation was later realised through the IGRIP software pakcage operating on a Silicon Graphics computing engine, which provides a 'Non-Immersive' Virtual Reality environment. Within this environment, models of the Irradiated Fuel Dismantling cell were generated along with a model of the manipulator, allowing manipulator deployment to the Irradiated Fuel Dismantling Cell be modelled. It is estimated that the first use of this new environment provided a significant saving to Scottish Nuclear in potential lost output. The use of this virtual reality environment is currently being extended into the design and deployment of a new manipulator for Torness in vessel inspection, the Boiler Inspection Manipulator. (author)

  14. Reality in Virtual Learning

    DEFF Research Database (Denmark)

    Lindberg, Frank; Pettersson, Michael

    professors most often decide what and when one could learn by providing the context and substance. In this perspective, the student has a role which is close to the one of a passive receiver, and s/he is mainly preoccupied with the problem of generating substance in memory most efficiently. Today, technology......-time educational logic. There are fewer attempts to use ICT according to a different pedagogical perspective than the old professor authoritarian model. The purpose of this paper is to illuminate some challenges virtual students experience when facing a new ICT-based learning situation. We will try to explore...... and develop understandings of what it might mean to be a student when learning occurs within a virtual problem based learning landscape. When students are used to the traditional classroom, challenges appear in the twilight zone between two pedagogical practices. How do the students cope with challenges...

  15. Virtual vitreoretinal surgery

    DEFF Research Database (Denmark)

    Vergmann, Anna Stage; Vestergaard, Anders Højslet; Grauslund, Jakob

    2017-01-01

    PURPOSE: To test the validity of the eyesi surgical simulator as an assessment tool in a virtual reality vitreoretinal training programme. METHODS: In collaboration with an experienced vitreoretinal surgeon, a virtual vitreoretinal training programme was composed on the eyesi surgical simulator......, software version 2.9.2 (VRmagic GmbH, Manheim, Germany). It was completed twice by three groups: 20 medical students, ten residents of ophthalmology and five trained vitreoretinal surgeons. The programme contained six training modules: navigation level 2 (Nav2), forceps training level 5 (ForT5), bimanual...... and microscope handling), and it was possible to achieve 100 points in each module. RESULTS: At the final training session, the highest overall median score was found for the vitreoretinal surgeons (vitreoretinal surgeons: 434 points, residents: 394.5 points, medical students: 272.5 points, p

  16. Virtual Reality Hospice

    OpenAIRE

    Ejsing, Sebastian Kirkegaard; Vintersborg, Kathrine Mosbæk; Benford-Brown, Cory George; Turner, Daniel Severin Pohl

    2017-01-01

    This paper details the findings of a qualitative reception analysis performed in collaboration with Hospice Sjælland, as to the potentials of Virtual Reality technology in providing entertainment and respite. The analysis was performed utilizing a theoretical analytical model based on Kim Schrøder’s ‘Multidimensional Model of Mass Media Reception’ to discourse gathered from six interviews with four patients from Hospice Sjælland. Supporting this model was supplementary literature on cognitive...

  17. Droni e turismo virtuale

    Directory of Open Access Journals (Sweden)

    Valeria Minucciani

    2015-08-01

    Full Text Available Virtual tourism has been through at least three generations. The first is a special form of e-commerce, and no doubt it has much changed the way you plan your travel. Second generation of virtual tourism has exploited georeference: the user can know the services offered nearby and, with appropriate apps and augmented reality, receive information about places. An important contribution has been made in this field by social media (see Flickr, as well as Tripadvisor. The third generation of virtual tourism even replaces the travel experience: first proposing visits in virtual worlds, then in the real world. That allows tourism to social classes that are excluded. The goal is to send in the real place an "avatar", that can perform what tourist wants. Some experiments have been recently performed with robots, here a visit by drones is proposed. In particular, indoor visits are difficult because it is necessary to re-create a microgeodetic reference system in a closed and confined environment, to allow remote control and to ensure the protection of the cultural property. It has also to be considered the issue of the size of the drone, its autonomy and shooting video (which must be 360 degrees and high definition. The real experience is irreplaceable, but this form of tourism can find many interesting applications and strengthen real tourism. In conclusion, we believe that not only this performances are now within the reach of our technical capabilities, but  they also represent an effective response to certain social and cultural issues.

  18. Virtual Personal Assistant

    OpenAIRE

    Imrie, Peter; Bednar, Peter

    2013-01-01

    Abstract This report discusses ways in which new technology could be harnessed to create an intelligent Virtual Personal Assistant (VPA) with a focus on user-based information. It will look at examples of intelligent programs with natural language processing that are currently available, with different categories of support, and examine the potential usefulness of one specific piece of software as a VPA. This engages the ability to communicate socially through natural language processing, hol...

  19. The virtual oil company

    International Nuclear Information System (INIS)

    Garibaldi, C.A.; Haney, R.M.; Ross, C.E.

    1995-01-01

    In anticipation of continuing declines in upstream activity levels over the next 15 years, the virtual oil company model articulates a vision of fewer, leaner, but financially stronger firms that concentrate only on their core competencies and outsource the rest through well-structured partnering arrangements. Freed from the ''clutter,'' these leading companies will be in better position to focus on those opportunities that offer the potential for renewed reserve and revenue growth

  20. Virtual Quantum Subsystems

    International Nuclear Information System (INIS)

    Zanardi, Paolo

    2001-01-01

    The physical resources available to access and manipulate the degrees of freedom of a quantum system define the set A of operationally relevant observables. The algebraic structure of A selects a preferred tensor product structure, i.e., a partition into subsystems. The notion of compoundness for quantum systems is accordingly relativized. Universal control over virtual subsystems can be achieved by using quantum noncommutative holonomies