WorldWideScience

Sample records for tomography virtual hysterosalpingography

  1. 64-Row multidetector CT virtual hysterosalpingography. Findings in 2500 patients

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Capunay, Carlos; Baronio, Mariano; Vallejos, Javier; Papier, Sergio; Carrascosa, Jorge

    2011-01-01

    Objective. To depict typical features of virtual hysterosalpingography (VHSG) in infertile patients. Material and methods: 2500 VHSG performed using a 64-row MOCT were evaluated. Results: Cervical abnormalities visualized corresponded to parietal irregularities (21%); thickened folds (9%); polyps (11%); diverticula (5%); cervical strictures (8%), and synechiae (1.5%). At the level of uterine cavity, polyps (44%); submucous myomas (8%); intramural and subserosal fibroids (11%); synechiae (10%); malformations (10%); adenomyosis (4%), and cesarean section scar (3%). Unilateral hydrosalpinx (7%) and bilateral hydrosalpinx (2%). Tubal obstruction was reported in 6% of cases. The average radiation dose was 0.94 mSv. Eighty-four percent of the patients reported mild pain or no postoperative discomfort. Conclusions: The virtual hysterosalpingography allowed a proper assessment of the internal genital organs, providing useful diagnostic information on infertility and other gynecological disorders. It constitutes a virtually painless, low-dose radiation technique, besides being well tolerated by patients

  2. Multidetector computed tomography virtual hysterosalpingography in the investigation of the uterus and fallopian tubes

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Baronio, Mariano; Capunay, Carlos; Lopez, Elba Martin; Vallejos, Javier; Borghi, Mario; Sueldo, Carlos; Papier, Sergio

    2008-01-01

    Objective: To compare the efficacy of multidetector CT virtual hysterosalpingography (MDCT-VH) with conventional X-ray hysterosalpingography (HSG) in the evaluation of patients with diagnosis of infertility. Methods: Sixty patients with diagnosis of infertility scheduled to perform a HSG, were evaluated with 16-row (n = 50) and 64-row (n = 10) MDCT-VH. In 35 patients the examination was performed without a tenaculum. The HSGs were carried out using standard technique. The HSG and MDCT-VH findings were compared. The duration for both examinations and patient discomfort were documented. The sensitivity and specificity of MDCT-VH for the detection of uterine pathology and tubal obstruction were calculated using the exact binomial method. Agreement between the two methods was assessed by the Cohen's kappa method (k). Results: The mean duration for MDCT-VH (16 and 64-rows) was 5 ± 3 min, whereas for HSG was 28 ± 3. The MDCT-VH without a tenaculum was the procedure with less patient discomfort. Sensitivity, specificity and inter-method agreement for the detection of uterine pathology were 100%, 92% and k = 0.92 for 16-row MDCT-VH and 100%, 100% and k = 1 for 64-row MDCT-VH, respectively. Sensitivity and specificity for detection of tubal obstruction were 80% and 80% for 16-row MDCT-VH and 100% and 100% for 64-row MDCT-VH, respectively; inter-method agreement for the visualization of the tubes was k = 0.54 for 16-row MDCT-VH and k = 1 for 64-row MDCT-VH. Conclusion: This study demonstrated the feasibility of evaluating the female reproductive system by MDCT-VH. 64-Row MDCT-VH could be an alternative diagnostic technique in the infertility workup algorithm. A larger study is in progress to validate these encouraging results

  3. Multidetector computed tomography virtual hysterosalpingography in the investigation of the uterus and fallopian tubes

    Energy Technology Data Exchange (ETDEWEB)

    Carrascosa, Patricia [Diagnostico Maipu, Av. Maipu 1668, Vicente Lopez B1602ABQ, Buenos Aires (Argentina)], E-mail: patriciacarrascosa@diagnosticomaipu.com.ar; Baronio, Mariano [CEGYR, Viamonte 1438, Capital Federal C1055ABB (Argentina); Capunay, Carlos; Lopez, Elba Martin; Vallejos, Javier [Diagnostico Maipu, Av. Maipu 1668, Vicente Lopez B1602ABQ, Buenos Aires (Argentina); Borghi, Mario; Sueldo, Carlos; Papier, Sergio [CEGYR, Viamonte 1438, Capital Federal C1055ABB (Argentina)

    2008-09-15

    Objective: To compare the efficacy of multidetector CT virtual hysterosalpingography (MDCT-VH) with conventional X-ray hysterosalpingography (HSG) in the evaluation of patients with diagnosis of infertility. Methods: Sixty patients with diagnosis of infertility scheduled to perform a HSG, were evaluated with 16-row (n = 50) and 64-row (n = 10) MDCT-VH. In 35 patients the examination was performed without a tenaculum. The HSGs were carried out using standard technique. The HSG and MDCT-VH findings were compared. The duration for both examinations and patient discomfort were documented. The sensitivity and specificity of MDCT-VH for the detection of uterine pathology and tubal obstruction were calculated using the exact binomial method. Agreement between the two methods was assessed by the Cohen's kappa method (k). Results: The mean duration for MDCT-VH (16 and 64-rows) was 5 {+-} 3 min, whereas for HSG was 28 {+-} 3. The MDCT-VH without a tenaculum was the procedure with less patient discomfort. Sensitivity, specificity and inter-method agreement for the detection of uterine pathology were 100%, 92% and k = 0.92 for 16-row MDCT-VH and 100%, 100% and k = 1 for 64-row MDCT-VH, respectively. Sensitivity and specificity for detection of tubal obstruction were 80% and 80% for 16-row MDCT-VH and 100% and 100% for 64-row MDCT-VH, respectively; inter-method agreement for the visualization of the tubes was k = 0.54 for 16-row MDCT-VH and k = 1 for 64-row MDCT-VH. Conclusion: This study demonstrated the feasibility of evaluating the female reproductive system by MDCT-VH. 64-Row MDCT-VH could be an alternative diagnostic technique in the infertility workup algorithm. A larger study is in progress to validate these encouraging results.

  4. Hysterosalpingography

    Science.gov (United States)

    ... For Patients Search FAQs Hysterosalpingography Page Navigation ▼ ACOG Pregnancy Book Hysterosalpingography Patient Education FAQs Hysterosalpingography Patient Education Pamphlets - Spanish Hysterosalpingography FAQ143, ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... Hysterosalpingography Hysterosalpingography uses a real-time form of x-ray called fluoroscopy to examine the uterus and fallopian ... is Hysterosalpingography? Hysterosalpingography, also called uterosalpingography, is an x-ray examination of a woman's uterus and fallopian tubes ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Hysterosalpingography Hysterosalpingography uses a ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... masses, adhesions and uterine fibroids. Hysterosalpingography can occasionally open blocked fallopian tubes to allow the patient to ... carrying a fetus to term. Hysterosalpingography can occasionally open fallopian tubes that are blocked allowing the patient ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... Index A-Z Hysterosalpingography Hysterosalpingography uses a real-time form of x-ray called fluoroscopy to examine ... or an untreated sexually transmitted disease at the time of the procedure. On the night before the ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. top of page What are the limitations of Hysterosalpingography? Hysterosalpingography only sees ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... the procedure? Hysterosalpingography is primarily used to examine women who have difficulty becoming pregnant by allowing the ... that might interfere with the x-ray images. Women should always inform their physician and x-ray ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... called fluoroscopy to examine the uterus and fallopian tubes of a woman who is having difficulty becoming ... uterine fibroids. Hysterosalpingography can occasionally open blocked fallopian tubes to allow the patient to become pregnant afterwards. ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... and to determine the presence and severity of these abnormalities, including: Tumor masses Adhesions Uterine fibroids Hysterosalpingography ... images are digital files that are stored electronically. These stored images are easily accessible and are frequently ...

  13. Hysterosalpingography

    International Nuclear Information System (INIS)

    Barbosa, J.R.; Barbosa, A.A.R.; Martins, A. Andre; Botter, L.C.; Barbosa, N.R.; Milano Filho, D.

    1987-01-01

    Several radiographics records with typical roentgen features in hysterosalpingography are presented. Congenital anomalies, myomas, polypus, hyperplasia of endometrium, adenomyosis, synechias, uterine carcinoma, tuba uterine and cervical canal alterations, caesarean section are briefly discussed. (M.A.C.) [pt

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... Hysterosalpingography, also called uterosalpingography, is an x-ray examination of a woman's uterus and fallopian tubes that ... look like? The equipment typically used for this examination consists of a radiographic table, one or two ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... hysterosalpingography, including, but not limited to, low or abnormal sperm count or the inability of a fertilized ... in X-Ray and CT Exams Contrast Materials Abnormal Vaginal Bleeding Cervical Cancer Endometrial Cancer X-ray, ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... of tumor masses, adhesions and uterine fibroids. Hysterosalpingography can occasionally open blocked fallopian tubes to allow the ... the uterine or peritoneal (abdominal) cavity . The procedure can be used to investigate repeated miscarriages that result ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... function. top of page What are some common uses of the procedure? Hysterosalpingography is primarily used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... information on a variety of abnormalities that cause infertility or problems carrying a fetus to term. Hysterosalpingography ... structures may be evaluated with MRI or ultrasound. Infertility problems may be from causes not evaluated with ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Hysterosalpingography is a minimally invasive procedure with ... in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers top of page ... related to Hysterosalpingography Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... Safety Images related to Hysterosalpingography Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... procedure work? How is the procedure performed? What will I experience during and after the procedure? Who interprets the results and how do I get them? What are the benefits vs. risks? What are the limitations of Hysterosalpingography? ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Hysterosalpingography is a minimally invasive procedure with rare ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... Wear loose, comfortable clothing and leave jewelry at home. You may be asked to wear a gown. What is Hysterosalpingography? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  5. Hysterosalpingography: analysis of 473 abnormal examinations

    International Nuclear Information System (INIS)

    Petta, C.A.; Costa-Paiva, L.H.S. da; Pinto-Neto, A.M.; Martins, R.; Souza, G.A.

    1990-01-01

    The authors reviewed the reports of 4/3 abnormal hysterosalpingographies from 1,200 medical records of patients at the sterility and infertility out-patient clinic of the School of Medical Sciences of the State University of Campinas (Unicamp), from July, 1974 to December, 1981. The objective was to evaluate the incidence and main alterations diagnosed by hysterosalpingography. The most frequent findings were tuboperitoneal factors in 91% of the examinations, uterine cavity abnormalities in 17.4% and cervical factor in 6.3% of the cases. The examinations showed a great incident of tuboperitoneal abnormalities as cause of sterility from lower social classes. (author) [pt

  6. Virtual electrical capacitance tomography sensor

    International Nuclear Information System (INIS)

    Li, Y; Yang, W Q

    2005-01-01

    Electrical capacitance tomography (ECT) is an effective technique for elucidating the distribution of dielectric materials inside closed pipes or vessels. This paper describes a virtual electrical capacitance tomography (VECT) system, which can simulate a range of sensor and hardware configurations and material distributions. A selection of popular image reconstruction algorithms has been made available and image error and capacitance error tools enable their performance to be evaluated and compared. Series of frame-by-frame results can be stored for simulating real-time dynamic flows. The system is programmed in Matlab with DOS functions. It is convenient to use and low-cost to operate, providing an effective tool for engineering experiment

  7. Hysterosalpingography and laparoscopy in infertile women

    International Nuclear Information System (INIS)

    Konarzewska, J.; Bianek-Bodzak, A.; Mielcarek, P.; Kobierski, J.

    2009-01-01

    Background: Despite dynamic development of diagnostic imaging methods and endoscopic procedures, X-ray hysterosalpingography remains the basic diagnostic procedure when anatomical cause of infertility is suspected. The aim of the study was to assess the correlation between HSG results and laparoscopy findings, especially in infertile women with normal results of hysterosalpingography. Material/Methods: The results of HSG and laparoscopies performed between 2002 and 2005 years in 53 infertile women were analyzed retrospectively. The indication for HSG was primary infertility in 44 cases and secondary infertility in 9 cases.Results: The result of HSG was normal in 51%. Pathological findings were observed in 49% of HSG and in 93% of laparoscopies. The most common pathological findings observed during laparoscopy were tubal occlusion (26% cases) and endometriosis (25% cases). Polycystic ovaries and myomas were observed in 20% of the performed laparoscopies. HSG and laparoscopy yield consistent results in evaluation of tubal patency (p < 0.001). Conclusions: HSG remains the method of first choice in the diagnostics of uterine malformations and tubal diseases as causes of infertility. When mechanical factors of female infertility are suspected, HSG allows the optimal choice of more invasive procedure. (authors)

  8. Structural findings at hysterosalpingography in patients with infertility ...

    African Journals Online (AJOL)

    Materials and Methods: A retrospective review of 289 consecutive patients who underwent hysterosalpingography using ionic water-soluble contrast media was done at 2 private x-ray units in Kampala. Clinical notes and radiological findings were analysed for demographic data, uterine status, tubal and pelvic pathology.

  9. Hysterosalpingography (HSG) findings: Of infertile patients in Ilorin ...

    African Journals Online (AJOL)

    Purpose/Background: Infertility is a major gynecological complaint in Nigeria, constituting about fifty percent (50%) of gynecological clinic attendance1-3. Hysterosalpingography (HSG) is used as a first line investigative procedure for evaluating infertility cases. An analysis of HSG findings of patients with primary and ...

  10. Virtual computed tomography cystoscopy in bladder pathologies

    International Nuclear Information System (INIS)

    Arslan, Halil; Ceylan, Kadir; Harman, Mustafa; Yilmaz, Yuksel; Temizoz, Osman; Can, Saban

    2006-01-01

    Objective: assessed the usefulness of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with different urinary bladder pathologies compared to the conventional cystoscopy.Materials and methods: eighteen patients with different bladder pathologies, which consisted of 11 tumors, 3 diverticula, 2 trabecular changes and 2 stones, were assessed with conventional cystoscopy and virtual CT cystoscopy. The results of virtual CT cystoscopy were compared with the findings of conventional cystoscopy. We determined the detection rate and positive predictive value of CT imaging based virtual cystoscopy in the diagnosis of urinary bladder lesions. Results: CT scanning was well tolerated by all patients, and no complications occurred. Images in 16 (88%) of the 18 virtual cystoscopic examinations were either of excellent or good quality. All tumors except one, 2 trabecular changes and 2 stones were characterized with similar findings in the both of methods. The masses ranged from 0.4 to 7.0 cm in diameter. While conventional cystoscopy could not evaluate interior part of the diverticulum, virtual CT cystoscopy could demonstrate clearly within it. There were no false-positive findings in our series. Conclusion: virtual CT cystoscopy is a promising technique to be used in the detection of bladder lesions. It should be considered especially at the evaluation of bladder diverticula. In the future, it may be possible or even advantageous to incorporate into the imaging algorithm for evaluation of bladder lesion. (author)

  11. Uterine and tubal anatomical abnormalities in infertile women: diagnosis with routine hysterosalpingography prior to selective laparoscopy

    Directory of Open Access Journals (Sweden)

    Mwaffaq Heis

    2011-12-01

    Full Text Available Objective: To assess the findings and usefulness of hysterosalpingography as a routine investigation in the fertility workup prior to selective laparoscopy. Design: Descriptive retrospective study. Setting: A university hospital in the north of Jordan. Subjects: All hysterosalpingographies performed in the period between 1st January and 31 December 2008. Outcome measures: Detection of uterine and fallopian tube abnormalities and their correlation with laparoscopic findings. Results: During the study period, 281 infertile women underwent hysterosalpingography with no post procedural complications. The mean (SD age was 31.5 (5.91 years. Mean (SD duration of infertility was 4 (3.44 years. Infertility was reported as primary and secondary by 119 (42.3 % and 162 (57.6 %, respectively. Altogether 281 patients and 562 tubes were examined. Of those, 402 were patent and 160 occluded. There was only one woman in whom peritubal adhesions were diagnosed. Because of hysterosalpingographically diagnosed tubal occlusion, 46 women (16.4 % were referred for laparoscopy. Eight (17.3% of them were treated with unilateral salpingectomy and 28 (60.8% with bilateral salpingectomy. Salpingolysis was performed for 7 (15.2% women, and 3 (6.7% women had untreatable adhesions. The concordance was 71.7%. The sensitivity of HSG was 80%, the specificity 50%, the negative predictive value 61% and the positive predictive value 71%. Of the total of 281 women, 30 (10.7% conceived within 1 - 11 months after the hysterosalpingography. Conclusions: The very high abnormal predictive value of hysterosalpingography in the diagnosis of tubal occlusion suggests that this procedure could be performed as a screening examination.

  12. Is hysterosalpingography still relevant in workup of infertility? A ...

    African Journals Online (AJOL)

    Objective: To examine the current role of Hysterosalpingography in the investigation of the infertile couple in view of the increasing use of Laparoscopy in the evaluation and management of infertility. Materials: Electronic search of published literature was done using the Pubmed, Cochrane libraries and Google search ...

  13. The effect of music on the anxiety levels of patients undergoing hysterosalpingography

    Energy Technology Data Exchange (ETDEWEB)

    Agwu, K.K. [Department of Medical Radiography and Radiological Sciences, Faculty of Health Sciences and Technology, University of Nigeria, Enugu Campus, Enugu (Nigeria)]. E-mail: kenagwu2000@yahoo.com; Okoye, I.J. [Department of Radiation Medicine, University of Nigeria Teaching Hospital, Enugu (Nigeria)

    2007-05-15

    Objectives: To determine the effect of music on the anxiety levels of patients undergoing a hysterosalpingography procedure. Patients and methods: One hundred hysterosalpingography referrals were randomly assigned to either the experimental or control group. Music chosen earlier by the patients was played during the hysterosalpingography procedure for the experimental group. The control group was studied without music. Certain physiological parameters and the State-Trait Anxiety Inventory were used to assess the patients' anxiety levels before and during the investigation. Patient's willingness to have a repeat procedure, should it become necessary, was also assessed in both groups as a measure of acceptability of the investigation. The z-test was used to analyze the results for any statistically significant differences between the experimental and the control groups. Results: The blood pressure (BP) monitored during the procedure was reduced in 31 (62%) of the patients in the experimental group compared to their pre-investigation values. Reduction in the pulse rate (PR) in 28 (56%) of the patients was also noted in the experimental group. On the other hand, the blood pressure of 37 (74%) of the patients and the pulse rate of 32 (64%) patients in the control group were increased from their pre-investigation values. The physiological parameters in the experimental group were significantly lower than the values in the control group during the investigation (p < 0.05). A comparison of the State-Trait Anxiety Inventory scores taken before and during the procedure shows significantly lower scores for the experimental group compared to those for the control group (p < 0.05). More patients, 41 (82%) in the experimental group were also willing to have a repeat procedure compared to 16 (32%) patients in the control. Conclusion: Music reduces the physiological and cognitive responses of anxiety in patients undergoing hysterosalpingography and can be harnessed for

  14. The effect of music on the anxiety levels of patients undergoing hysterosalpingography

    International Nuclear Information System (INIS)

    Agwu, K.K.; Okoye, I.J.

    2007-01-01

    Objectives: To determine the effect of music on the anxiety levels of patients undergoing a hysterosalpingography procedure. Patients and methods: One hundred hysterosalpingography referrals were randomly assigned to either the experimental or control group. Music chosen earlier by the patients was played during the hysterosalpingography procedure for the experimental group. The control group was studied without music. Certain physiological parameters and the State-Trait Anxiety Inventory were used to assess the patients' anxiety levels before and during the investigation. Patient's willingness to have a repeat procedure, should it become necessary, was also assessed in both groups as a measure of acceptability of the investigation. The z-test was used to analyze the results for any statistically significant differences between the experimental and the control groups. Results: The blood pressure (BP) monitored during the procedure was reduced in 31 (62%) of the patients in the experimental group compared to their pre-investigation values. Reduction in the pulse rate (PR) in 28 (56%) of the patients was also noted in the experimental group. On the other hand, the blood pressure of 37 (74%) of the patients and the pulse rate of 32 (64%) patients in the control group were increased from their pre-investigation values. The physiological parameters in the experimental group were significantly lower than the values in the control group during the investigation (p < 0.05). A comparison of the State-Trait Anxiety Inventory scores taken before and during the procedure shows significantly lower scores for the experimental group compared to those for the control group (p < 0.05). More patients, 41 (82%) in the experimental group were also willing to have a repeat procedure compared to 16 (32%) patients in the control. Conclusion: Music reduces the physiological and cognitive responses of anxiety in patients undergoing hysterosalpingography and can be harnessed for clinical

  15. Patient dosimetry in hysterosalpingography

    International Nuclear Information System (INIS)

    Khoury, H.J.; Maia, A.; Oliveira, M.; Kramer, R.; Drexler, G.

    2001-01-01

    The objectives of this study were to determine the entrance surface dose to the patient and to estimate the dose to the uterus and ovaries due to hysterosalpingography (HSG) diagnostic examinations performed in Recife-Pe, Brazil. The entrance doses were measured using four thermoluminescent dosimeters per patient, attached to anatomical landmarks on the patient's skin. The study was carried out on 25 patients between 21 and 45 years of age who underwent the HSG examinations in two training hospitals and one private radiodiagnostic institute. The number of exposures performed ranged from 4 to 15 radiographs per patient measured. Entrance surface doses varied between 4.99 and 36.6 mGy, with an average of 12.6mGy. The doses to the ovaries and uterus ranged from 0.80 mGy to 5.8 mGy and 1.10mGy to 8.05 mGy, respectively. (author)

  16. The value of hysterosalpingography using non-ionic contrast agent combined with low-tensive drug in diagnosis of infertility

    International Nuclear Information System (INIS)

    Deng Qiwei; Liu Xiaojun; Shi Jianfen; Jiang Guohua; Ye Jinqing; Shen Jun; Song Ting

    2009-01-01

    Objective: To analyze the value of nonionic contrast agent combined with low tensive drug in the hysterosalpingography in diagnosis of infertility. Methods: 203 patients with infertility were randomly classified into two groups. Group 1 contained 108 patients administrated intramuscularly anisodamine (654-2) 30 minutes before hysterosalpingography. 95 patients in group 2 did not use 654-2. Non-ionic contrast agent was used in all patients. The image quality and post-contrast displaying status of uterus and uterine tube between the two groups were analyzed. Results: No allergic response occurred in all patients. The image quality and post-contrast displaying status of uterus and uterine tube of group 1 were obviously superior to that of group 2 (P<0.01). Conclusion: Hysterosalpingography clearly showed lesions of uterus and uterine tube when using non-ionic contrast agent combined with low-tensive drug. It is more safety with less side effects. The contraction of uterine tube can be relieved by the low-tensive drug effectively, so as to decrease the false positive rate, raise the diagnostic accuracy, and lessen patients sufferings. It is deserved to be applied generally. (authors)

  17. Is hysterosalpingography able to diagnose all uterine malformations correctly? A retrospective study

    International Nuclear Information System (INIS)

    Braun, Petra; Grau, Francisco Vercher; Pons, Raul Mut; Enguix, Daniel Perez

    2005-01-01

    Background: Muellerian duct anomalies are an uncommon but often a treatable cause of infertility. Material and methods: From January 2002 until November 2003, a total of 705 hysterosalpingographies were realised of which 658 were analysed retrospectively in order to determine the importance of uterine malformations in infertile and sterile patients. In ten cases, the results of hysterosalpingography were compared with hysteroscopy and laparoscopy. Results: The frequency of uterine malformations in infertile and sterile women was 10%. In this population, arcuate uterus (57.6%) was the most common malformation, followed by subseptate uterus (18.2%), uterus bicornis unicollis (10.6%), uterus bicornis bicollis (3.0%), septate uterus (6.1%), unicornuate uterus (3.0%) and unicornuate uterus with double vagina (1.5%). Discussion: Our bibliographic research confirmed that arcuate uterus is the most frequent congenital malformation, but in gestations it does not show a significantly reduced live birth rate. Nevertheless, the septate uterus presents an important decrease of live birth rate that can be improved significantly by doing hysteroscopic metroplasty. As this is a completely different surgical intervention compared to bicornuate uterus, a correct diagnosis is very important. Differentiation of these two malformations is quite difficult by hysterosalpingographic exploration, wherefore an additional exploration by means of endovaginal or three-dimensional ultrasound is recommended

  18. Is hysterosalpingography able to diagnose all uterine malformations correctly? A retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Petra; Grau, Francisco Vercher; Pons, Raul Mut; Enguix, Daniel Perez

    2005-02-01

    Background: Muellerian duct anomalies are an uncommon but often a treatable cause of infertility. Material and methods: From January 2002 until November 2003, a total of 705 hysterosalpingographies were realised of which 658 were analysed retrospectively in order to determine the importance of uterine malformations in infertile and sterile patients. In ten cases, the results of hysterosalpingography were compared with hysteroscopy and laparoscopy. Results: The frequency of uterine malformations in infertile and sterile women was 10%. In this population, arcuate uterus (57.6%) was the most common malformation, followed by subseptate uterus (18.2%), uterus bicornis unicollis (10.6%), uterus bicornis bicollis (3.0%), septate uterus (6.1%), unicornuate uterus (3.0%) and unicornuate uterus with double vagina (1.5%). Discussion: Our bibliographic research confirmed that arcuate uterus is the most frequent congenital malformation, but in gestations it does not show a significantly reduced live birth rate. Nevertheless, the septate uterus presents an important decrease of live birth rate that can be improved significantly by doing hysteroscopic metroplasty. As this is a completely different surgical intervention compared to bicornuate uterus, a correct diagnosis is very important. Differentiation of these two malformations is quite difficult by hysterosalpingographic exploration, wherefore an additional exploration by means of endovaginal or three-dimensional ultrasound is recommended.

  19. Role of 3.0 Tesla magnetic resonance hysterosalpingography in the diagnostic work-up of female infertility.

    Science.gov (United States)

    Cipolla, Valentina; Guerrieri, Daniele; Pietrangeli, Daniela; Santucci, Domiziana; Argirò, Renato; de Felice, Carlo

    2016-09-01

    Imaging evaluation plays a crucial role in the diagnostic work-up of female infertility. In recent years, the possibility to evaluate tubal patency using 1.5 Tesla magnetic resonance (1.5T MR) has been studied. To assess the feasibility of 3.0 Tesla magnetic resonance (3.0T MR) hysterosalpingography and its role in the diagnostic work-up of female infertility and to evaluate if this fast "one-stop-shop" imaging approach should be proposed as a first-line examination. A total of 116 infertile women were enrolled in this prospective study; all underwent 3.0T MR hysterosalpingography. After standard imaging of the pelvis, tubal patency was assessed by acquiring 3D dynamic time-resolved T1-weighted (T1W) sequences during manual injection of 4-5 mL of contrast solution consisting of gadolinium and normal sterile saline. Images were evaluated by two radiologists with different experience in MR imaging (MRI). The examination was successfully completed in 96.5% of cases, failure rate was 3.5%. Dynamic sequences showed bilateral tubal patency in 64.3%, unilateral tubal patency in 25.9%, and bilateral tubal occlusion in 9.8%. Extratubal abnormalities were found in 69.9% of patients. Comprehensive analysis of morphological and dynamic sequences showed extratubal abnormalities in 43.1% of patients with bilateral tubal patency. 3.0T MR hysterosalpingography is a feasible, simple, fast, safe, and well-tolerated examination, which allows evaluation of tubal patency and other pelvic causes of female infertility in a single session, and it may thus represent a "one-stop-shop" solution in female infertility diagnostic work-up. © The Foundation Acta Radiologica 2015.

  20. Estimate of worker and patient exposures and quality control in hysterosalpingography exams

    International Nuclear Information System (INIS)

    Rodrigues, Barbara Beatriz Dias

    2006-06-01

    Hysterosalpingography (HSG) is a relatively frequent radiological procedure, which is used to access and study the uterine cavity and the tubary permeability. The estimate of the radiation doses received by the patients, and of the associated risks, has become of great interest in recent years. The importance in evaluating the received doses becomes even higher when the gonads region is irradiated; as in the case of hysterosalpingography, where the patients are relatively young, existing a high probability of future pregnancy. In HSG procedure the physician stays beside the patient, being also exposed. The purpose of this study was to analyze, during HSG procedures, the exposition of patients, measuring the kerma-area (P K,A ) product by using an ionization chamber of big area, to evaluate the doses received by the radiologist using thermoluminescent dosemeters and to evaluate the quality of image by means of qualitative methods. The results gotten during the accompaniment of 86 examinations had been the following ones: the average P K,A was 706 ± 388 cGy.cm 2 , to an average exposition time of 2 ± 1 minutes. In order to optimize the exposure of patients and workers, the time of scopy and the number of images should be reduced, whenever it is possible. Due to the significant values of equivalent dose received by the lens, the use of plumbiferous eyeglasses is recommended. (author)

  1. Efficacy of virtual computerized tomography laparoscopy for retroperitoneoscopic nephrectomy

    International Nuclear Information System (INIS)

    Shigeta, Masanobu; Kadonishi, Yuichi; Yasumoto, Hiroaki; Mita, Koji; Usui, Tsuguru; Marukawa, Kazushi

    2004-01-01

    Retroperitoneoscopic nephrectomy is less invasive than open nephrectomy, and is an alternative surgical procedure for renal tumors and upper urothelial tumors. We evaluated the efficacy of virtual computerized tomography laparoscopy (VCTL) as a navigator for retroperitoneoscopic nephrectomy to ascertain the correct anatomy of the renal hilum pre-operatively under the retroperitoneoscopic view. Seventy-three kidneys with localized renal tumors (n=44), upper urothelial tumors (n=23), or benign renal disease (n=6) underwent multidetector-row CT. VCTL was carried out by the volume-rendered technique. The findings were compared with those of real retroperitoneoscopy. After the operation, each operator scored 1 to 5 in evaluating the usefulness of virtual retroperitoneoscopy (score 5 indicated very useful). The percentages of renal arteries depicted by VCTL compared with those noted during real surgery were 93% for kidneys with renal tumors, 100% for upper urothelial tumors and 83% for benign renal disease. Two renal arteries of 2 kidneys were not detected by virtual imaging. These were about 1 mm in diameter and directly branched from the aorta, however retroperitoneoscopic nephrectomy was performed uneventfully. VCTL depicted all the renal veins. The anatomy of the renal hilum seen on VCTL and real retroperitoneoscopy was identical, without the minor angle deviation caused by drawing the kidney during the operation. The average score for the usefulness of VCTL was 4.1, ranging from 3 to 5. The accurate surgical anatomy of the renal hilum could be predicted in almost all patients pre-operatively. VCTL is an excellent navigator for retroperitoneoscopic nephrectomy. (author)

  2. Therapeutic value of hysterosalpingography with Lipiodol ultra fluid

    International Nuclear Information System (INIS)

    Rasmussen, F.; Justesen, P.; Toenner Nielsen, D.

    1987-01-01

    Hysterosalpingography (HSG) with Lipiodol ultra fluid was performed in 294 infertile women with a normal ovulatory temperature curve and at least two years of infertility and a partner with normal sperm. In 21%, pregnancy occurred within 6 months after the examination, and about one third of the women with a normal finding or with intraperitoneal adhesions at HSG conceived. The pregnancy rate was especially high in the first two cycles after HSG. The spontaneous pregnancy rate was 8%, and the difference between this and the total number of pregnancies must be attributed to a therapeutic effect of the procedure. Previous pelvic inflammatory disease was present in 40% of those who did not become pregnant, while only 11% of those who conceived had previous inflammation. Of the women without previous gynecologic disease 30% conceived. (orig.)

  3. Head to head comparison of optical coherence tomography, intravascular ultrasound echogenicity and virtual histology for the detection of changes in polymeric struts over time

    DEFF Research Database (Denmark)

    Brugaletta, Salvatore; Gomez-Lara, Josep; Bruining, Nico

    2012-01-01

    To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation. In the A......To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation...

  4. Head and neck computed tomography virtual endoscopy: evaluation of a new imaging technique.

    Science.gov (United States)

    Gallivan, R P; Nguyen, T H; Armstrong, W B

    1999-10-01

    To evaluate a new radiographic imaging technique: computed tomography virtual endoscopy (CTVE) for head and neck tumors. Twenty-one patients presenting with head and neck masses who underwent axial computed tomography (CT) scan with contrast were evaluated by CTVE. Comparisons were made with video-recorded images and operative records to evaluate the potential utility of this new imaging technique. Twenty-one patients with aerodigestive head and neck tumors were evaluated by CTVE. One patient had a nasal cylindrical cell papilloma; the remainder, squamous cell carcinomas distributed throughout the upper aerodigestive tract. Patients underwent complete head and neck examination, flexible laryngoscopy, axial CT with contrast, CTVE, and in most cases, operative endoscopy. Available clinical and radiographic evaluations were compared and correlated to CTVE findings. CTVE accurately demonstrated abnormalities caused by intraluminal tumor, but where there was apposition of normal tissue against tumor, inaccurate depictions of surface contour occurred. Contour resolution was limited, and mucosal irregularity could not be defined. There was very good overall correlation between virtual images, flexible laryngoscopic findings, rigid endoscopy, and operative evaluation in cases where oncological resections were performed. CTVE appears to be most accurate in evaluation of subglottic and nasopharyngeal anatomy in our series of patients. CTVE is a new radiographic technique that provides surface-contour details. The technique is undergoing rapid technical evolution, and although the image quality is limited in situations where there is apposition of tissue folds, there are a number of potential applications for this new imaging technique.

  5. Evaluation of occupational radiation dose of extremities on hysterosalpingography

    International Nuclear Information System (INIS)

    Filipov, D.; Kotowski, S.T.A.

    2017-01-01

    In the Hysterosalpingography (HSG) exam there is always a professional present with their hands very close to the radiation field. Based on CNEN, individuals occupationally exposed to radiation have equivalent dose limit values for the extremities (500 mSv / year). The objective of the study was to verify the equivalent dose in the hand region of an IOE (Occupationally Exposed Individual) that performs the HSG test and to compare it with the CNEN limit and with similar studies. A humanoid phantom was used to simulate the patient and an ionization chamber, which was placed in the place commonly occupied by the professional. The equivalent hand dose result (∼ 30 mSv / year) equals 6% of the CNEN annual dose limit, but is close to most studies using fluoroscopes. Therefore, the optimization of radiological protection is necessary to reduce these results

  6. Radiogenic risks from hysterosalpingography

    International Nuclear Information System (INIS)

    Perisinakis, Kostas; Damilakis, John; Theocharopoulos, Nicholas; Grammatikakis, John; Gourtsoyiannis, Nicholas

    2003-01-01

    The aim of this study was to determine ovarian dose, effective dose and associated radiogenic risks from hysterosalpingography (HSG), and to provide data for the estimation of radiogenic risks related to HSG studies performed in any laboratory. The fluoroscopy time, number of radiographs taken and entrance surface dose were measured in a series of 78 consecutive patients undergoing HSG as part of their infertility work-up. Organ-dose values per radiograph and per minute of fluoroscopy were separately determined using an anthropomorphic phantom and thermoluminescence dosimetry. The radiogenic risk for deleterious effects on a possible future embryo and the radiogenic risk for cancer induction on the patient undergoing HSG were estimated. The average HSG procedure in our laboratory involves a mean fluoroscopic time of 0.3 min and a mean number of radiographs of 3.2. The dose to female gonads from an average HSG procedure was 2.7 mGy and the patient effective dose was 1.2 mSv. The risk for radiogenic anomalies in a future embryo of the woman undergoing an average HSG procedure and the risk for radiogenic fatal cancer induction in the exposed woman were estimated to be less than 10 -3 of the correspondent nominal risks. Radiation risks from a typical HSG are low, but they may be elevated if fluoroscopic and/or radiographic exposures are prolonged for any reason. Present data allow the estimation of radiogenic risks associated with HSG procedures performed in other laboratories with use of different equipment, screening time and number of radiographs taken. (orig.)

  7. A comparative study of hysterosalpingography and endoscopy/laparotomy in infertile patients

    International Nuclear Information System (INIS)

    Nielsen, D.T.; Rasmussen, F.; Justesen, P.

    1987-01-01

    A comparison of hysterosalpingography (HSG), using Lipiodol ultrafluid as contrast medium, with endoscopy/laparotomy in the evaluation of the tubal function in 124 infertile women is presented. There was agreement between the results of both methods in 73.4% of the patients. The false-negative rate was 2.4% and the false-positive rate was 8.9%. Complications in the form of intravasation were seen in three patients but none of them had any symptoms. The conception rate was 35% in the subgroup of patients with normal HSG. The authors recommended the continuous use of HSG in the overall evaluation of infertile patients. It is recommended to use oil-soluble contrast media because of its high diagnostic accuracy, low frequency of complications and its therapeutic advantages. (orig.)

  8. Radiation dose in hysterosalpingography: modern 100mm fluorography vs. full-scale radiography

    International Nuclear Information System (INIS)

    Seppaenen, S.; Lehtinen, E.; Holli, H.

    1978-01-01

    Radiation doses of modern 100 mm fluorography and full-scale radiography were compared experimentally and applied to hysterosalpingography. It was determined that 100 mm fluorography reduced the doses by 28 to 29 percent per exposure and 37 to 47 percent per examination compared with full-scale radiography performed with fast tungstate screens in identical conditions (70 to 80 kV, 400 mA). The dose during one minute of videofluoroscopy was equivalent to the doses produced by one exposure in full-scale filming and three to four exposures in 100 mm filming. Although electronic magnification in 100 mm fluorography increases the doses by two or threefold, these are still less than the doses in full-scale radiography

  9. Assessment in dogs tympanic bulla, through virtual tomographic endoscopy; Avaliacao de bulas timpanicas em caes, por meio da endoscopia tomografica virtual

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Luciana Carandina da; Sabino, Emanuelle Guidugli, E-mail: lucianacarandina@uol.com.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria. Dept. de Reproducao Animal e Radiologia Veterinaria; Vulcano, Luiz Carlos; Machado, Vania Maria de Vasconcelos [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria

    2012-07-01

    Dogs usually have problems related to the auditory canal. For the diagnosis of these pathologies, it is necessary a physical examination and, in some cases radiographic examination and computed tomography. The tympanic bulla is not easily visualized radiographically, since there is many structures of the brain overlaying the image obtained. The computed tomography has been the technique of choice to assess this structure faithfully. A new alternative assessment of the tympanic bulla is tomographic virtual endoscopy, which allows an improvement of the image obtained through the virtual tomographic technique. This paper provides information on the use of computed tomography, and a new technique, tomographic virtual endoscopy, in order to make the improvement of these techniques, and prove the reliability of these changes in the diagnosis of ear canals of dogs. Therefore, we performed the computed tomography of the tympanic bulla on healthy animals, and later performed image reconstruction in three-dimensional (3D) mode for virtual endoscopy. (author)

  10. The geometrical precision of virtual bone models derived from clinical computed tomography data for forensic anthropology.

    Science.gov (United States)

    Colman, Kerri L; Dobbe, Johannes G G; Stull, Kyra E; Ruijter, Jan M; Oostra, Roelof-Jan; van Rijn, Rick R; van der Merwe, Alie E; de Boer, Hans H; Streekstra, Geert J

    2017-07-01

    Almost all European countries lack contemporary skeletal collections for the development and validation of forensic anthropological methods. Furthermore, legal, ethical and practical considerations hinder the development of skeletal collections. A virtual skeletal database derived from clinical computed tomography (CT) scans provides a potential solution. However, clinical CT scans are typically generated with varying settings. This study investigates the effects of image segmentation and varying imaging conditions on the precision of virtual modelled pelves. An adult human cadaver was scanned using varying imaging conditions, such as scanner type and standard patient scanning protocol, slice thickness and exposure level. The pelvis was segmented from the various CT images resulting in virtually modelled pelves. The precision of the virtual modelling was determined per polygon mesh point. The fraction of mesh points resulting in point-to-point distance variations of 2 mm or less (95% confidence interval (CI)) was reported. Colour mapping was used to visualise modelling variability. At almost all (>97%) locations across the pelvis, the point-to-point distance variation is less than 2 mm (CI = 95%). In >91% of the locations, the point-to-point distance variation was less than 1 mm (CI = 95%). This indicates that the geometric variability of the virtual pelvis as a result of segmentation and imaging conditions rarely exceeds the generally accepted linear error of 2 mm. Colour mapping shows that areas with large variability are predominantly joint surfaces. Therefore, results indicate that segmented bone elements from patient-derived CT scans are a sufficiently precise source for creating a virtual skeletal database.

  11. Simple improvement in the technique of hysterosalpingography achieving optimal imaging and avoiding possible complications

    International Nuclear Information System (INIS)

    Beyth, Y.; Navot, D.; Lax, E.

    1985-01-01

    A simple technique is reported in which oil-soluble contrast media (OSCM) are used with hysterosalpingography to investigate infertility in women due to uterine and tubal pathology. The advantages of OSCM as compared with water-soluble contrast media (WSCM) are described. Complications caused by intravasation of the OSCM into lymph vessels and veins are avoided by clearing the media at the end of the procedure. This also results in the immediate spread of the contrast media in the pelvic cavity with the result that delayed radiographs become superfluous and the radiation dose to the genitals is reduced. 4 references, 2 figures

  12. The use of cone-beam computed tomography and virtual reality simulation for pre-surgical practice in endodontic microsurgery.

    Science.gov (United States)

    Suebnukarn, S; Rhienmora, P; Haddawy, P

    2012-07-01

    To design and evaluate the impact of virtual reality (VR) pre-surgical practice on the performance of actual endodontic microsurgery.   The VR system operates on a laptop with a 1.6-GHz Intel processor and 2 GB of main memory. Volumetric cone-beam computed tomography (CBCT) data were acquired from a fresh cadaveric porcine mandible prior to endodontic microsurgery. Ten inexperienced endodontic trainees were randomized as to whether they performed endodontic microsurgery with or without virtual pre-surgical practice. The VR simulator has microinstruments to perform surgical procedures under magnification. After the initial endodontic microsurgery, all participants served as their own controls by performing another procedure with or without virtual pre-surgical practice. All procedures were videotaped and assessed by two independent observers using an endodontic competency rating scale (from 6 to 30). A significant difference was observed between the scores for endodontic microsurgery on molar teeth completed with virtual pre-surgical practice and those completed without virtual presurgical practice, median 24.5 (range = 17-28) versus median 18.75 (range = 14-26.5), P = 0.041. A significant difference was observed between the scores for osteotomy on a molar tooth completed with virtual pre-surgical practice and those completed without virtual pre-surgical practice, median 4.5 (range = 3.5-4.5) versus median 3 (range = 2-4), P = 0.042. Pre-surgical practice in a virtual environment using the 3D computerized model generated from the original CBCT image data improved endodontic microsurgery performance. © 2012 International Endodontic Journal.

  13. [Comparison of diagnostic quality in hysterosalpingography between iodinated non-ionic contrast media with low and high osmolarity].

    Science.gov (United States)

    Piccotti, K; Guida, D; Carbonetti, F; Stefanetti, L; Macioce, A; Cremona, A; David, V

    Comparison of diagnostic quality in hysterosalpingography between low and high-osmolality contrast media. We performed a retrospective evaluation of two cohorts of patients who underwent HSG using contrast media with different osmolarity: the first group ,47 patients, underwent hysterosalpingography in the period September 2011-December 2012 using Iopromide 370 mg/ml; the second group, 50 patients, underwent HSG from January 2013 to October 2013 using Iomeprol 400 mg/ml. Three radiologists, in consensus reading,, reviewed the radiographs by assessing the following four parameters: opacification of the uterine cavity, uterine profiles definition, Fallopian tubes visualization, contrast media spillage into peritoneum. A score-scale from 0 to 3 was assigned for each of the mentioned parameter (0 = minimum non-diagnostic exam, 1 = sufficient examination; 2 = good quality examination; maximum 3 = high quality images). We documented a statistically significant higher quality in displaying Fallopian tubes among patients studied through high osmolarity contrast medium (Iopromide 370 mg/ml) than what obtained through lower osmolarity contrast medium (Iomeprol 400 mg/ml). The use of high osmolarity contrast medium enabled better visualization of the tubes and a greater number of diagnoses of chronic aspecific salpigintis due to the increased osmolality and viscosity of Iomeprol 400 mg/ml. There were no significant differences between the two contrast agents in the evaluation of intra-uterine pathology and in the evaluation of the tubal patency.

  14. Post-Essure hysterosalpingography compliance in a clinic population.

    Science.gov (United States)

    Shavell, Valerie I; Abdallah, Mazen E; Diamond, Michael P; Kmak, David C; Berman, Jay M

    2008-01-01

    To determine the follow-up rate for post-Essure hysterosalpingography (HSG) in a non-study, general clinic population in an urban environment. Retrospective chart review (Canadian Task Force classification II-2). University teaching hospital. Eighty-three University Health Center (UHC) patients who underwent attempted placement of the Essure permanent birth control device at the ambulatory surgery center at Hutzel Women's Hospital from January 2003 through June 2007. Hysteroscopic placement of the Essure permanent birth control device. Placement of the Essure permanent birth control device was attempted in 83 patients, of which 79 were successfully completed (95.2%). Of the 79 patients, 10 underwent post-Essure HSG (12.7%). HSG was performed 3 to 6 months after placement of the Essure device. Bilateral tubal occlusion was documented in all 10 patients. Despite preoperative and postoperative counseling, the follow-up rate for post-Essure HSG for this clinic population was only 12.7%. For those in whom HSG was performed, bilateral tubal occlusion was confirmed in all. Steps or approaches to promote compliance with postprocedural confirmation of tubal occlusion should be utilized to improve future follow-up rates.

  15. Pyosalpinges after hysterosalpingography in a patient with lower genital tract infection and managed by laparoscopic surgery in a resource low tertiary hospital case report and literature review.

    Science.gov (United States)

    Egbe, Thomas Obinchemti; Kobenge, Fidelia Mbi; Arlette, Metogo Mbengono Junette; Belley-Priso, Eugene

    2018-01-01

    Pyosalpinges (a complication of pelvic inflammatory disease) is infection of the fallopian tubes and the morbidity associated with it has major health implications. We are reporting a case of pyosalpinges diagnosed after hysterosalpingography and managed by laparoscopic surgery at the Douala General Hospital, Cameroon. A 29-year-old single woman, an assistant nurse of the Douala tribe in Cameroon. She is G1P0010 and came to our attention because of secondary infertility of three years duration. She has a history consistent with four lifetime sexual partners, self-medication for chlamydia trachomatis infection and induced abortion by dilatation and aspiration. Furthermore, she is HIV positive and had an ultrasound scan suggestive of bilateral hydrosalpinges. After a hysterosalpingography examination she developed painless muco-purulent vaginal discharge and bilateral adnexal tenderness on bimanual examination suggestive of pyosalpinges. Vaginal and cervical cultures isolated Ureaplasma urealyticum and Gardnerella vaginalis sensitive to ofloxacin and metronidazole, respectively.At laparoscopy, bilateral pyosalpinges, pelvic adhesions and peri-hepatic adhesions were found. Bilateral salpingectomy with adhesiolysis including lysis of perihepatic adhesions and peritoneal toileting was done. She was discharged from hospital 72 h later and her hospital stay was uneventful. She was counseled for in-vitro fertilization and to register in the national HIV treatment programme. Her husband was prescribed ofloxacin empirically. Antimicrobial prophylaxis should be given to patients prior to HSG, especially those with a history of chlamydia or evidence of hydrosalpinges. There should also be universal STI testing in high risk and HIV positive patients or the danger for suboptimal antibiotic usage in areas where self-medication is common.In resource-low tertiary hospitals where computed tomography or magnetic resonance imaging is not readily available and/or affordable, clinical

  16. A cone-beam computed tomography triple scan procedure to obtain a three-dimensional augmented virtual skull model appropriate for orthognathic surgery planning.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mollemans, W.; Clercq, C. De; Abeloos, J.V.S.; Lamoral, P.; Lippens, F.R.C.; Neyt, N.; Casselman, J.W.; Schutyser, F.A.C.

    2009-01-01

    The aim of this study was to present a new approach to acquire a three-dimensional virtual skull model appropriate for orthognathic surgery planning without the use of plaster dental models and without deformation of the facial soft-tissue mask. A "triple" cone-beam computed tomography (CBCT) scan

  17. The use of a wax bite wafer and a double computed tomography scan procedure to obtain a three-dimensional augmented virtual skull model.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mommaerts, M.Y.; Abeloos, J.V.S.; Clercq, C. De; Lamoral, P.; Neyt, N.; Casselman, J.W.; Schutyser, F.A.C.

    2007-01-01

    A detailed visualization of the interocclusal relationship is essential in a three-dimensional virtual planning setup for orthognathic and facial orthomorphic surgery. The purpose of this study was to introduce and evaluate the use of a wax bite wafer in combination with a double computed tomography

  18. The impact of different cone beam computed tomography and multi-slice computed tomography scan parameters on virtual three-dimensional model accuracy using a highly precise ex vivo evaluation method.

    Science.gov (United States)

    Matta, Ragai-Edward; von Wilmowsky, Cornelius; Neuhuber, Winfried; Lell, Michael; Neukam, Friedrich W; Adler, Werner; Wichmann, Manfred; Bergauer, Bastian

    2016-05-01

    Multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT) are indispensable imaging techniques in advanced medicine. The possibility of creating virtual and corporal three-dimensional (3D) models enables detailed planning in craniofacial and oral surgery. The objective of this study was to evaluate the impact of different scan protocols for CBCT and MSCT on virtual 3D model accuracy using a software-based evaluation method that excludes human measurement errors. MSCT and CBCT scans with different manufacturers' predefined scan protocols were obtained from a human lower jaw and were superimposed with a master model generated by an optical scan of an industrial noncontact scanner. To determine the accuracy, the mean and standard deviations were calculated, and t-tests were used for comparisons between the different settings. Averaged over 10 repeated X-ray scans per method and 19 measurement points per scan (n = 190), it was found that the MSCT scan protocol 140 kV delivered the most accurate virtual 3D model, with a mean deviation of 0.106 mm compared to the master model. Only the CBCT scans with 0.2-voxel resolution delivered a similar accurate 3D model (mean deviation 0.119 mm). Within the limitations of this study, it was demonstrated that the accuracy of a 3D model of the lower jaw depends on the protocol used for MSCT and CBCT scans. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Aortic endograft surveillance: use of fast-switch kVp dual-energy computed tomography with virtual noncontrast imaging.

    Science.gov (United States)

    Maturen, Katherine E; Kleaveland, Patricia A; Kaza, Ravi K; Liu, Peter S; Quint, Leslie E; Khalatbari, Shokoufeh H; Platt, Joel F

    2011-01-01

    To assess endoleak detection and patients' radiation exposure using fast-switch peak kilovoltage (kVp) dual-energy computed tomography (DECT) with virtual noncontrast (VNC) imaging. Institutional review board approved retrospective review of triphasic CTs for endograft follow-up: single-energy true noncontrast (TNC) and dual-energy arterial- and venous-phase postcontrast scans on GE HD-750 64-detector scanners. Iodine-subtracted VNC images generated from dual-energy data. Two radiologists (VNC readers) independently performed 2 reading sessions without TNC images: (1) arterial and VNC and (2) venous and VNC. Interrater agreement, leak detection sensitivity, and dose estimates were calculated. Original dictations described 24 endoleaks in 78 scans. Virtual noncontrast reader agreement was high (κ = 0.78-0.79). Virtual noncontrast reader ranges for sensitivity and negative predictive value for leak detection were 87.5% to 95.8% and 94.0% to 98.0% in venous phase. Dose reduction estimate was 40% by eliminating one phase and 64% by eliminating 2 phases of imaging. Virtual noncontrast images from fast-switch peak kilovoltage DECT data can substitute for TNC imaging in the postendograft aorta, conferring substantial dose reduction. Eliminating 1 of 2 postcontrast phases further reduces dose, with greater negative predictive value for leak detection in the venous versus the arterial phase. Thus, the use of a monophasic venous-phase DECT with VNC images is suggested for long-term endograft surveillance in stable patients.

  20. Image Guided Virtual Autopsy: An Adjunct with Radiographic and Computed Tomography Modalities - An Important Tool in Forensic Identification

    Directory of Open Access Journals (Sweden)

    Shalu Rai

    2017-01-01

    Full Text Available The forensic examination of dead bodies is very helpful in order to identify the person, cause of death, gender, and solving the mysterious cases. It includes a number of techniques, out of which autopsy is the primary investigation that is performed in every medicolegal case. Because of mutilation technologies, traditional autopsy technique is most disturbing in terms of emotions and rituals of relatives. The use of radiology in forensic science comprises performance, interpretation, and reporting of radiographs that is helpful in detecting those changes that are not clinically visible. Forensic radiology plays an important role for identification of humans in mass disasters, criminal investigations, and evaluation of cause of death. The introduction of radiological modalities in autopsy techniques is a complementary tool for forensic identification and is known as virtual autopsy. The advance imaging techniques such as computed tomography (CT and magnetic resonance imaging (MRI is used in virtual autopsy in order to visualize and reconstruct the internal organs to know the site, type, and depth of injury. This review elaborates the role of maxillofacial imaging in image-guided virtual autopsy.

  1. ViRPET--combination of virtual reality and PET brain imaging

    Science.gov (United States)

    Majewski, Stanislaw; Brefczynski-Lewis, Julie

    2017-05-23

    Various methods, systems and apparatus are provided for brain imaging during virtual reality stimulation. In one example, among others, a system for virtual ambulatory environment brain imaging includes a mobile brain imager configured to obtain positron emission tomography (PET) scans of a subject in motion, and a virtual reality (VR) system configured to provide one or more stimuli to the subject during the PET scans. In another example, a method for virtual ambulatory environment brain imaging includes providing stimulation to a subject through a virtual reality (VR) system; and obtaining a positron emission tomography (PET) scan of the subject while moving in response to the stimulation from the VR system. The mobile brain imager can be positioned on the subject with an array of imaging photodetector modules distributed about the head of the subject.

  2. Clinical application of hysterosalpingography with a double-lumen catheter of a contrast media combination consisting iohexol and saline

    International Nuclear Information System (INIS)

    Xi Jiayuan; Jiang Yong; Cao Xinhua; Zhu Ying; Lv Liang; Zhao Xinxiang; Wei Dingying; Shao Jingxuan; Hua Jian

    2005-01-01

    Objective: To evaluate the clinical value of hysteosalpingographic diagnosis in infertile women. Methods: After a catheter with a double-lumen saccule was inserted into the uterine cavity, saline or air of 2.5-3.5 ml was injected to fill the saccule. The filled saccule was inserted at the isthmus of uterus for blocking the internal orifice. The contrast medium was injected through the catheter into the uterine cavity and fallopian tubes to undertake hysterosalpingography and fallopian tube reopening. In case of fallopian tube obstruction, the injection pressure could be increased to obtain recanalization. All operations and selective imagings were carried out under TV supervision. Results: 2698 cases including 806 primary infertile women and 1868 secondary infertile women were examined by this method. Technical success rate was 99.5% with 2198 cases (81.9%) having normal uterus, 249 (9.3%) congenital abnormal uterus and 238 (8.9%) uterus diseases. The number of obstructed fallopian tube was 3028 with 117 serious hydropsy (3.8%). Ninety-eight cases had been examined with lipiodol hysterosalpingography in other hospitals with 35 cases still having lipiodol accumulated within the uterine cavities and fallopian tubes. No serious complications or death occurred except slight pain. Conclusions: Double-lumen cather with a contrast media combination of iohexol and saline for hysterosal pinography is safe, easy and effective, outcoming with excellent quality images. More information can be gained with this method than traditional lipiodol hyterosalpinography, and furthermore could have compression during radiogrophy and avoid the long term stasis of lipiodol. (authors)

  3. Estimation of effective dose during hysterosalpingography procedures; Estimación de dosis efectiva durante los procedimientos hysterosalpingography

    Energy Technology Data Exchange (ETDEWEB)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M. [King Saud University, College of Applied Medical Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433, (Saudi Arabia); Sulieman, A. [Salman bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P. O. Box 422, Alkharj (Saudi Arabia); Alsafi, K. [King Abdulaziz University, Faculty of Medicine, Radiology Department, Jeddah 22254 (Saudi Arabia); Omer, H., E-mail: kalzimami@ksu.edu.sa [Dammam University, Faculty of Medicine, Dammam Khobar Coastal Rd, Khobar 31982 (Saudi Arabia)

    2014-08-15

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  4. Effectiveness of paracervical block for pain relief in women undergoing hysterosalpingography

    Directory of Open Access Journals (Sweden)

    Shikha Jain

    2016-01-01

    Full Text Available Objectives: To evaluate the potential benefit, in terms of pain relief, of the paracervical block with 2% lignocaine in women undergoing hysterosalpingography (HSG. Study Design: This study was a prospective randomized controlled study. Settings: This study was conducted in infertility clinic of a tertiary care center. Materials and Methods: Four hundred and six patients undergoing HSG as a part of infertility evaluation were included in the study. These women were randomized into two groups: Group I received paracervical block with 2% lignocaine at the time of HSG (n = 53 and Group II (n = 53 served as control. Hyoscine (10 mg oral tablet was given to all the patients 30 min before the procedure. Pain perception during the procedure was analyzed by the patient between 0 and 10 on a numeric rating scale, immediately after HSG. Results: The baseline demographic characteristics of participants in two groups were similar. Mean pain score immediately after HSG in the study group and control group was 4.84 ± 2.56 and 5.21 ± 1.89, respectively (P = 0.21. Conclusions : There is no benefit of paracervical block with 2% lignocaine, in terms of pain relief, in women undergoing HSG.

  5. Estimation of effective dose during hysterosalpingography procedures

    International Nuclear Information System (INIS)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M.; Sulieman, A.; Alsafi, K.; Omer, H.

    2014-08-01

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  6. Hyperthyroidism secondary to hysterosalpingography: an extremely rare complication: A case report.

    Science.gov (United States)

    Ma, Guotao; Mao, Rui; Zhai, Haixin

    2016-12-01

    Hysterosalpingography (HSG), a standard procedure for the evaluation of women with infertility and repetitive pregnancy loss, is associated with complications such as uterine perforation, infection, allergic reactions, syncope, hemorrhage and shock, and pulmonary or retinal embolus. However, hyperthyroidism has not been reported as one of its complications. We report the case of a 33-year-old euthyroid woman who presented to our hospital with palpitation, hand tremor, fatigue, and excessive sweating after HSG. Thyroid function tests revealed a thyroid stimulating hormone (TSH) level of 0.012 μIU/mL (range 0.38-4.34 μIU/mL), free T4 of 2.886 ng/dL (range 0.81-1.89 ng/dL), and free T3 levels of 9.4 pg/mL (range 1.80-4.10 pg/mL), and antithyroglobulin antibody of 31.78 IU/mL (range hyperthyroidism (IIH), but was not treated with antithyroid drugs. She has spontaneously recovered and is pregnant currently. This is the first reported case of overt IIH caused by HSG in a euthyroid patient without risk factors. It suggests that HSG also leads to excessive iodine absorption, which induces secondary hyperthyroidism.

  7. Can hysterosalpingocontrast-sonography replace hysterosalpingography in the assessment of tubal subfertility?

    Science.gov (United States)

    Dijkman, A B; Mol, B W; van der Veen, F; Bossuyt, P M; Hogerzeil, H V

    2000-07-01

    Hysterosalpingo-contrastsonography (HyCoSy) is a new method for assessing tubal patency using transvaginal ultrasound. It is thought to have several advantages over conventional hysterosalpingography (HSG). We prospectively evaluated the performance of HyCoSy and HSG in the diagnosis of tubal pathology. One-hundred consecutive subfertile women underwent both HyCoSy and HSG in randomised order. Results of both tests were related to findings at laparoscopy with dye, which was used as the reference test. Each woman was asked to score the pain exsperienced at both procedures on a visual analogue scale. When laparoscopy with dye was used as reference test, the likelihood ratios of HyCoSy were slightly inferior to those obtained for HSG. Since the performance of HyCoSy was dependent on experience, the results were recalculated omitting the 50 initial procedures from the analysis. In that calculation, results of HyCoSy and HSG were comparable. There were no differences in pain experienced during the procedure, as there appeared also to be no differences in patient preferences. There appear to be no strong arguments either to replace HSG by HyCoSy, or to reject the use of HyCoSy. Both procedures can be used in the evaluation of tubal pathology.

  8. Dual-Energy Computed Tomography in Stroke Imaging: Technical and Clinical Considerations of Virtual Noncontrast Images for Detection of the Hyperdense Artery Sign.

    Science.gov (United States)

    Winklhofer, Sebastian; Vittoria De Martini, Ilaria; Nern, Chrisitian; Blume, Iris; Wegener, Susanne; Pangalu, Athina; Valavanis, Antonios; Alkadhi, Hatem; Guggenberger, Roman

    The technical feasibility of virtual noncontrast (VNC) images from dual-energy computed tomography (DECT) for the detection of the hyperdense artery sign (HAS) in ischemic stroke patients was investigated. True noncontrast (TNC) scans of 60 patients either with or without HAS (n = 30 each) were investigated. Clot presence and characteristics were assessed on VNC images from DECT angiography and compared with TNC images. Clot characterization included the level of confidence for diagnosing HAS, a qualitative clot burden score, and quantitative attenuation (Hounsfield unit [HU]) measurements. Sensitivity, specificity, and accuracy of VNC for diagnosing HAS were 97%, 90%, and 93%, respectively. No significant differences were found regarding the diagnostic confidence (P = 0.18) and clot burden score (P = 0.071). No significant HU differences were found among vessels with HAS in VNC (56 ± 7HU) and TNC (57 ± 8HU) (P = 0.691) images. Virtual noncontrast images derived from DECT enable an accurate detection and characterization of HAS.

  9. Improving Rates of Post-Essure Hysterosalpingography in an Urban Population Using Electronic Tracking Reminders.

    Science.gov (United States)

    Virginia Hu, Yu-Han; Arora, Kavita Shah

    2017-02-01

    To demonstrate the efficacy of electronic reminders for follow-up hysterosalpingography (HSG) after Essure hysteroscopic sterilization in an urban tertiary care hospital obstetrics and gynecology practice. Retrospective cohort study (Canadian Task Force classification II-3). Obstetrics and gynecology practice at a university-affiliated urban tertiary care teaching hospital. Two hundred and fifty patients who underwent Essure hysteroscopic sterilization between June 2011 and July 2014. Implementation of electronic reminders for the office staff. Two hundred and fifty of 259 patients (96.5%) underwent Essure hysteroscopic sterilization and successful placement of coils into bilateral Fallopian tubes. Among these 250 patients, 135 (54%) returned for HSG at 3 months post-Essure as advised at the time of procedure. The use of electronic reminders prompted another 45 patients (18%) to return for HSG, improving the total post-Essure follow-up rate to 72%. Electronic reminders for the office staff of an urban tertiary care hospital's obstetrics and gynecology practice is an effective method for improving the rate of post-Essure HSG. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  10. Generation of realistic virtual nodules based on three-dimensional spatial resolution in lung computed tomography: A pilot phantom study.

    Science.gov (United States)

    Narita, Akihiro; Ohkubo, Masaki; Murao, Kohei; Matsumoto, Toru; Wada, Shinichi

    2017-10-01

    The aim of this feasibility study using phantoms was to propose a novel method for obtaining computer-generated realistic virtual nodules in lung computed tomography (CT). In the proposed methodology, pulmonary nodule images obtained with a CT scanner are deconvolved with the point spread function (PSF) in the scan plane and slice sensitivity profile (SSP) measured for the scanner; the resultant images are referred to as nodule-like object functions. Next, by convolving the nodule-like object function with the PSF and SSP of another (target) scanner, the virtual nodule can be generated so that it has the characteristics of the spatial resolution of the target scanner. To validate the methodology, the authors applied physical nodules of 5-, 7- and 10-mm-diameter (uniform spheres) included in a commercial CT test phantom. The nodule-like object functions were calculated from the sphere images obtained with two scanners (Scanner A and Scanner B); these functions were referred to as nodule-like object functions A and B, respectively. From these, virtual nodules were generated based on the spatial resolution of another scanner (Scanner C). By investigating the agreement of the virtual nodules generated from the nodule-like object functions A and B, the equivalence of the nodule-like object functions obtained from different scanners could be assessed. In addition, these virtual nodules were compared with the real (true) sphere images obtained with Scanner C. As a practical validation, five types of laboratory-made physical nodules with various complicated shapes and heterogeneous densities, similar to real lesions, were used. The nodule-like object functions were calculated from the images of these laboratory-made nodules obtained with Scanner A. From them, virtual nodules were generated based on the spatial resolution of Scanner C and compared with the real images of laboratory-made nodules obtained with Scanner C. Good agreement of the virtual nodules generated from

  11. The Internet and medical collaboration using virtual reality.

    Science.gov (United States)

    Liang, Wen Yau; O'Grady, Peter

    2003-01-01

    Computed Tomography (CT) provides a large amount of data but the presentation of the data to a physician can be less than satisfactory. Ideally, the image data should be available to physicians in interactive 3D to allow for improved visualization, planning and diagnosis. A virtual reality representation that not only allows for the manipulation of the image but also allows for the user to, in effect, move inside the image remotely would be ideal. In this paper the research associated with virtual reality is discussed. A formalism is then presented to create, from the CT data, the virtual reality world in the Virtual Reality Modeling Language. An implementation is described of this formalism that uses the Internet to allow for users in remote locations to view and manipulate the virtual worlds.

  12. Estimate of worker and patient exposures and quality control in hysterosalpingography exams; Estimativa da exposicao de pacientes e trabalhadores e controle de qualidade em exames de histerossalpingografia

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Barbara Beatriz Dias

    2006-06-15

    Hysterosalpingography (HSG) is a relatively frequent radiological procedure, which is used to access and study the uterine cavity and the tubary permeability. The estimate of the radiation doses received by the patients, and of the associated risks, has become of great interest in recent years. The importance in evaluating the received doses becomes even higher when the gonads region is irradiated; as in the case of hysterosalpingography, where the patients are relatively young, existing a high probability of future pregnancy. In HSG procedure the physician stays beside the patient, being also exposed. The purpose of this study was to analyze, during HSG procedures, the exposition of patients, measuring the kerma-area (P{sub K,A}) product by using an ionization chamber of big area, to evaluate the doses received by the radiologist using thermoluminescent dosemeters and to evaluate the quality of image by means of qualitative methods. The results gotten during the accompaniment of 86 examinations had been the following ones: the average P{sub K,A} was 706 {+-} 388 cGy.cm{sup 2}, to an average exposition time of 2 {+-} 1 minutes. In order to optimize the exposure of patients and workers, the time of scopy and the number of images should be reduced, whenever it is possible. Due to the significant values of equivalent dose received by the lens, the use of plumbiferous eyeglasses is recommended. (author)

  13. Can hysterosalpingocontrast-sonography replace hysterosalpingography in the assessment of tubal subfertility?

    Energy Technology Data Exchange (ETDEWEB)

    Dijkman, Antonius B.; Mol, Ben W.J.; Veen, Fulco van der; Bossuyt, P.M.M.; Hogerzeil, Hendricus V

    2000-07-01

    Introduction: Hysterosalpingo-contrastsonography (HyCoSy) is a new method for assessing tubal patency using transvaginal ultrasound. It is thought to have several advantages over conventional hysterosalpingography (HSG). We prospectively evaluated the performance of HyCoSy and HSG in the diagnosis of tubal pathology. Methods and patients: One-hundred consecutive subfertile women underwent both HyCoSy and HSG in randomised order. Results of both tests were related to findings at laparoscopy with dye, which was used as the reference test. Each woman was asked to score the pain exsperienced at both procedures on a visual analogue scale. Results: When laparoscopy with dye was used as reference test, the likelihood ratios of HyCoSy were slightly inferior to those obtained for HSG. Since the performance of HyCoSy was dependent on experience, the results were recalculated omitting the 50 initial procedures from the analysis. In that calculation, results of HyCoSy and HSG were comparable. There were no differences in pain experienced during the procedure, as there appeared also to be no differences in patient preferences. Conclusion: There appear to be no strong arguments either to replace HSG by HyCoSy, or to reject the use of HyCoSy. Both procedures can be used in the evaluation of tubal pathology.

  14. Can hysterosalpingocontrast-sonography replace hysterosalpingography in the assessment of tubal subfertility?

    International Nuclear Information System (INIS)

    Dijkman, Antonius B.; Mol, Ben W.J.; Veen, Fulco van der; Bossuyt, P.M.M.; Hogerzeil, Hendricus V.

    2000-01-01

    Introduction: Hysterosalpingo-contrastsonography (HyCoSy) is a new method for assessing tubal patency using transvaginal ultrasound. It is thought to have several advantages over conventional hysterosalpingography (HSG). We prospectively evaluated the performance of HyCoSy and HSG in the diagnosis of tubal pathology. Methods and patients: One-hundred consecutive subfertile women underwent both HyCoSy and HSG in randomised order. Results of both tests were related to findings at laparoscopy with dye, which was used as the reference test. Each woman was asked to score the pain exsperienced at both procedures on a visual analogue scale. Results: When laparoscopy with dye was used as reference test, the likelihood ratios of HyCoSy were slightly inferior to those obtained for HSG. Since the performance of HyCoSy was dependent on experience, the results were recalculated omitting the 50 initial procedures from the analysis. In that calculation, results of HyCoSy and HSG were comparable. There were no differences in pain experienced during the procedure, as there appeared also to be no differences in patient preferences. Conclusion: There appear to be no strong arguments either to replace HSG by HyCoSy, or to reject the use of HyCoSy. Both procedures can be used in the evaluation of tubal pathology

  15. Super-Virtual Refraction Interferometric Redatuming: Enhancing the Refracted Energy

    KAUST Repository

    Aldawood, Ali

    2012-02-26

    onshore seismic data processing. Refraction tomography is becoming a common way to estimate an accurate near surface velocity model. One of the problems with refraction tomography is the low signal to noise ration in far offset data. To improve, we propose using super-virtual refraction interferometry to enhance the weak energy at far offsets. We use Interferometric Green\\'s functions to redatum sources by cross-correlating two traces recorded at receiver stations, A and B, from a source at location W. The result is a redatumed trace with a virtual source at A and a receiver at B, which can also be obtained by correlating two traces recorded at A and B from different shots. Stacking them would enhance the signal-to-noise ratio of this "virtual" trace. We next augment redatuming with convolution and stacking. The trace recorded at B from a virtual source at A is convolved with the original trace recorded at A from a source at W. The result is a "super-virtual" trace at B in the far-offset from a source at W. Stacking N traces gives a vN-improvement. We applied our method to noisy synthetic and field data recorded over a complex near-surface and we could pick more traces at far offsets. It was possible to accommodate more picks resulting in a better subsurface coverage

  16. Super-Virtual Refraction Interferometric Redatuming: Enhancing the Refracted Energy

    KAUST Repository

    Aldawood, Ali; Alshuhail, Abdulrahman Abdullatif Abdulrahman; Hanafy, Sherif

    2012-01-01

    onshore seismic data processing. Refraction tomography is becoming a common way to estimate an accurate near surface velocity model. One of the problems with refraction tomography is the low signal to noise ration in far offset data. To improve, we propose using super-virtual refraction interferometry to enhance the weak energy at far offsets. We use Interferometric Green's functions to redatum sources by cross-correlating two traces recorded at receiver stations, A and B, from a source at location W. The result is a redatumed trace with a virtual source at A and a receiver at B, which can also be obtained by correlating two traces recorded at A and B from different shots. Stacking them would enhance the signal-to-noise ratio of this "virtual" trace. We next augment redatuming with convolution and stacking. The trace recorded at B from a virtual source at A is convolved with the original trace recorded at A from a source at W. The result is a "super-virtual" trace at B in the far-offset from a source at W. Stacking N traces gives a vN-improvement. We applied our method to noisy synthetic and field data recorded over a complex near-surface and we could pick more traces at far offsets. It was possible to accommodate more picks resulting in a better subsurface coverage

  17. Reduced iodinated contrast media for abdominal imaging by dual-layer spectral detector computed tomography for patients with kidney disease

    Directory of Open Access Journals (Sweden)

    Hirokazu Saito, MD

    2018-04-01

    Full Text Available Contrast-enhanced computed tomography using iodinated contrast media is useful for diagnosis of gastrointestinal diseases. However, contrast-induced nephropathy remains problematic for kidney diseases patients. Although current guidelines recommended the use of a minimal dose of contrast media necessary to obtain adequate images for diagnosis, obtaining adequate images with sufficient contrast enhancement is difficult with conventional computed tomography using reduced contrast media. Dual-layer spectral detector computed tomography enables the simultaneous acquisition of low- and high-energy data and the reconstruction of virtual monochromatic images ranging from 40 to 200 keV, retrospectively. Low-energy virtual monochromatic images can enhance the contrast of images, thereby facilitating reduced contrast media. In case 1, abdominal computed tomography angiography at 50 keV using 40% of the conventional dose of contrast media revealed the artery that was the source of diverticular bleeding in the ascending colon. In case 2, ischemia of the transverse colon was diagnosed by contrast-enhanced computed tomography and iodine-selective imaging using 40% of the conventional dose of contrast media. In case 3, advanced esophagogastric junctional cancer was staged and preoperative abdominal computed tomography angiography could be obtained with 30% of the conventional dose of contrast media. However, the texture of virtual monochromatic images may be a limitation at low energy. Keywords: Virtual monochromatic images, Contrast-induced nephropathy

  18. Super-virtual refraction interferometry: Theory

    KAUST Repository

    Bharadwaj, Pawan

    2011-01-01

    Inverting for the subsurface velocity distribution by refraction traveltime tomography is a well-accepted imaging method by both the exploration and earthquake seismology communities. A significant drawback, however, is that the recorded traces become noisier with increasing offset from the source position, and so prevents accurate picking of traveltimes in far-offset traces. To enhance the signal-to-noise ratio of the far-offset traces, we present the theory of super-virtual refraction interferometry where the signal-to-noise ratio (SNR) of far-offset head-wave arrivals can be theoretically increased by a factor proportional to N; here, N is the number of receiver and source positions associated with the recording and generation of the head-wave arrival. There are two steps to this methodology: correlation and summation of the data to generate traces with virtual head-wave arrivals, followed by the convolution of the data with the virtual traces to create traces with super-virtual head-wave arrivals. This method is valid for any medium that generates head-wave arrivals. There are at least three significant benefits to this methodology: 1). enhanced SNR of far-offset traces so the first-arrival traveltimes of the noisy far-offset traces can be more reliably picked to extend the useful aperture of data, 2). the SNR of head waves in a trace that arrive after the first arrival can be enhanced for accurate traveltime picking and subsequent inversion by traveltime tomography, and 3). common receiver-pair gathers can be analyzed to detect the presence of diving waves in the first arrivals, which can be used to assess the nature of the refracting boundary. © 2011 Society of Exploration Geophysicists.

  19. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography

    International Nuclear Information System (INIS)

    Lopes, Cintya Carolina Barbosa

    2006-04-01

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  20. Translation of First North American 50 and 70 cc Total Artificial Heart Virtual and Clinical Implantations: Utility of 3D Computed Tomography to Test Fit Devices.

    Science.gov (United States)

    Ferng, Alice S; Oliva, Isabel; Jokerst, Clinton; Avery, Ryan; Connell, Alana M; Tran, Phat L; Smith, Richard G; Khalpey, Zain

    2017-08-01

    Since the creation of SynCardia's 50 cc Total Artificial Hearts (TAHs), patients with irreversible biventricular failure now have two sizing options. Herein, a case series of three patients who have undergone successful 50 and 70 cc TAH implantation with complete closure of the chest cavity utilizing preoperative "virtual implantation" of different sized devices for surgical planning are presented. Computed tomography (CT) images were used for preoperative planning prior to TAH implantation. Three-dimensional (3D) reconstructions of preoperative chest CT images were generated and both 50 and 70 cc TAHs were virtually implanted into patients' thoracic cavities. During the simulation, the TAHs were projected over the native hearts in a similar position to the actual implantation, and the relationship between the devices and the atria, ventricles, chest wall, and diaphragm were assessed. The 3D reconstructed images and virtual modeling were used to simulate and determine for each patient if the 50 or 70 cc TAH would have a higher likelihood of successful implantation without complications. Subsequently, all three patients received clinical implants of the properly sized TAH based on virtual modeling, and their chest cavities were fully closed. This virtual implantation increases our confidence that the selected TAH will better fit within the thoracic cavity allowing for improved surgical outcome. Clinical implantation of the TAHs showed that our virtual modeling was an effective method for determining the correct fit and sizing of 50 and 70 cc TAHs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  1. Dual-energy computed tomography in patients with cutaneous malignant melanoma: Comparison of noise-optimized and traditional virtual monoenergetic imaging.

    Science.gov (United States)

    Martin, Simon S; Wichmann, Julian L; Weyer, Hendrik; Albrecht, Moritz H; D'Angelo, Tommaso; Leithner, Doris; Lenga, Lukas; Booz, Christian; Scholtz, Jan-Erik; Bodelle, Boris; Vogl, Thomas J; Hammerstingl, Renate

    2017-10-01

    The aim of this study was to investigate the impact of noise-optimized virtual monoenergetic imaging (VMI+) reconstructions on quantitative and qualitative image parameters in patients with cutaneous malignant melanoma at thoracoabdominal dual-energy computed tomography (DECT). Seventy-six patients (48 men; 66.6±13.8years) with metastatic cutaneous malignant melanoma underwent DECT of the thorax and abdomen. Images were post-processed with standard linear blending (M_0.6), traditional virtual monoenergetic (VMI), and VMI+ technique. VMI and VMI+ images were reconstructed in 10-keV intervals from 40 to 100keV. Attenuation measurements were performed in cutaneous melanoma lesions, as well as in regional lymph node, subcutaneous and in-transit metastases to calculate objective signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Five-point scales were used to evaluate overall image quality and lesion delineation by three radiologists with different levels of experience. Objective indices SNR and CNR were highest at 40-keV VMI+ series (5.6±2.6 and 12.4±3.4), significantly superior to all other reconstructions (all Ptraditional VMI in patients with cutaneous malignant melanoma at thoracoabdominal DECT. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Offline fusion of co-registered intravascular ultrasound and frequency domain optical coherence tomography images for the analysis of human atherosclerotic plaques

    DEFF Research Database (Denmark)

    Räber, Lorenz; Heo, Jung Ho; Radu, Maria D

    2012-01-01

    To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images.......To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images....

  3. Virtual landmarks

    Science.gov (United States)

    Tong, Yubing; Udupa, Jayaram K.; Odhner, Dewey; Bai, Peirui; Torigian, Drew A.

    2017-03-01

    Much has been published on finding landmarks on object surfaces in the context of shape modeling. While this is still an open problem, many of the challenges of past approaches can be overcome by removing the restriction that landmarks must be on the object surface. The virtual landmarks we propose may reside inside, on the boundary of, or outside the object and are tethered to the object. Our solution is straightforward, simple, and recursive in nature, proceeding from global features initially to local features in later levels to detect landmarks. Principal component analysis (PCA) is used as an engine to recursively subdivide the object region. The object itself may be represented in binary or fuzzy form or with gray values. The method is illustrated in 3D space (although it generalizes readily to spaces of any dimensionality) on four objects (liver, trachea and bronchi, and outer boundaries of left and right lungs along pleura) derived from 5 patient computed tomography (CT) image data sets of the thorax and abdomen. The virtual landmark identification approach seems to work well on different structures in different subjects and seems to detect landmarks that are homologously located in different samples of the same object. The approach guarantees that virtual landmarks are invariant to translation, scaling, and rotation of the object/image. Landmarking techniques are fundamental for many computer vision and image processing applications, and we are currently exploring the use virtual landmarks in automatic anatomy recognition and object analytics.

  4. Characterizing root system characteristics with Electrical resistivity Tomography: a virtual rhizotron simulation

    Science.gov (United States)

    Rao, Sathyanarayan; Ehosioke, Solomon; Lesparre, Nolwenn; Nguyen, Frédéric; Javaux, Mathieu

    2017-04-01

    Electrical Resistivity Tomography (ERT) is more and more used for monitoring soil water content in a cropped soil. Yet, the impact of roots on the signal is often neglected and a topic of controversy. In several studies related to soil-root system, it has been showed that the measured root mass density statistically correlates with the electrical conductivity (EC) data obtained from ERT. In addition, some studies suggest that some roots are more electrically conductive than soil for most water content. Thus, higher EC of roots suggest that it might have a measurable impact on ERT signals. In this work, virtual rhizotrons are simulated using the software package called R-SWMS that solves water and solute transport in plant root-soil system, including root growth. The distribution of water content obtained from R-SWMS simulation is converted into EC data using pedo-physical models. The electrical properties of roots and rhizosphere are explicitly included in the EC data to form a conductivity map (CM) with a very detailed spatial resolution. Forward ERT simulations is then carried out for CM generated for various root architectures and soil conditions to study the impact of roots on ERT forward (current and voltage patterns) and inverse solutions. It is demonstrated that under typical injection schemes with lateral electrodes, root system is hardly measurable. However, it is showed that adding electrodes and constraints on the ERT inversion based on root architecture help quantifying root system mass and extent.

  5. Use of the stereoscopic virtual reality display system for the detection and characterization of intracranial aneurysms: A Icomparison with conventional computed tomography workstation and 3D rotational angiography.

    Science.gov (United States)

    Liu, Xiujuan; Tao, Haiquan; Xiao, Xigang; Guo, Binbin; Xu, Shangcai; Sun, Na; Li, Maotong; Xie, Li; Wu, Changjun

    2018-07-01

    This study aimed to compare the diagnostic performance of the stereoscopic virtual reality display system with the conventional computed tomography (CT) workstation and three-dimensional rotational angiography (3DRA) for intracranial aneurysm detection and characterization, with a focus on small aneurysms and those near the bone. First, 42 patients with suspected intracranial aneurysms underwent both 256-row CT angiography (CTA) and 3DRA. Volume rendering (VR) images were captured using the conventional CT workstation. Next, VR images were transferred to the stereoscopic virtual reality display system. Two radiologists independently assessed the results that were obtained using the conventional CT workstation and stereoscopic virtual reality display system. The 3DRA results were considered as the ultimate reference standard. Based on 3DRA images, 38 aneurysms were confirmed in 42 patients. Two cases were misdiagnosed and 1 was missed when the traditional CT workstation was used. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the conventional CT workstation were 94.7%, 85.7%, 97.3%, 75%, and99.3%, respectively, on a per-aneurysm basis. The stereoscopic virtual reality display system missed a case. The sensitivity, specificity, PPV, NPV, and accuracy of the stereoscopic virtual reality display system were 100%, 85.7%, 97.4%, 100%, and 97.8%, respectively. No difference was observed in the accuracy of the traditional CT workstation, stereoscopic virtual reality display system, and 3DRA in detecting aneurysms. The stereoscopic virtual reality display system has some advantages in detecting small aneurysms and those near the bone. The virtual reality stereoscopic vision obtained through the system was found as a useful tool in intracranial aneurysm diagnosis and pre-operative 3D imaging. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Difficulties in recruitment for a randomized controlled trial involving hysterosalpingography

    Directory of Open Access Journals (Sweden)

    Helmerhorst Frans M

    2006-06-01

    Full Text Available Abstract Background The usefulness of hysterosalpingography (HSG as routine investigation in the fertility work-up prior to laparoscopy and dye had been assessed in a randomized controlled trial. Recruiting subjects to the study was more difficult than anticipated. The objective of this study was to explore possible reasons for non-participation in the trial. Methods All newly referred subfertile women admitted to the Reproductive Medicine Clinic of Leiden University Medical Centre between 1 April 1997 and 31 December 1999, were eligible for the study. The reasons for non-participation were evaluated by scrutinizing the medical records. Results Out of 759 women, a total of 127 (17% agreed to participate in the trial. The most important reason for non-participation was because of exclusion criteria (73%. Other reasons were inattentive clinicians (3% and patient-associated reasons (24%. Patient refusal and indecisiveness to enroll in the study were the most common patient-associated reasons. The most frequently stated reason for trial refusal was reluctance to undergo laparoscopy and dye mainly due to issues related to anesthesia and scheduling of procedure. Conclusion Almost three-quarters of recruitment difficulties in this study were due to unavoidable reasons. To overcome the remaining avoidable reasons for non-participation, attention should be paid to appropriate instruction of the study protocol to the participating doctors and to provide adequate information, in layman's terms, to the patients. Reminding patients by notes or telephone calls for attending the clinic are helpful. It may be contingent upon tracing the reasons of clinicians and patients for non-participation to improve enrollment during a trial.

  7. Comparison of hysterosalpingography and laparoscopy in the evaluation of infertile women

    International Nuclear Information System (INIS)

    Sakar, Mehmet N.; Atay, Ahmet E.; Gul, T.; Celik, Y.

    2008-01-01

    Objective was to compare tuboperitoneal factors of infertile women hysterosalpingography (HSG) and laparoscopy. In this cohort study, 82 infertile cases were evaluated retrospectively by laparoscopy, 3 months subsequent to HSG in the Department of Gynecology and Obstetrics, Medical School of Dicle University, Diyarbakir, Turkey between March 2004 and April 2006. The findings of HSG and laparoscopy were compared. Out of 82 infertile women, pathological findings were observed in 45.1% by HSG and 54.9% had no pathological findings. On laparoscopic evaluation, however, pathological findings were observed in 65.85% and 34.15% had no pathological findings. The pathological findings were detected by laparoscopy in 20 of the 45(44.4%) patients who had had no pathological findings by HSG and no pathological findings were detected by laparoscopy in 3 of the 37 (8.1%) patients who had pathological findings by HSG. Laparoscopy revealed no pathological findings in 6 of 35 patients who had tubal pathology by HSG. The sensitivity of HSG was 63%, specificity was 89.3% and positive predictive value was 92% with a 55% predictive value and the accuracy ratio was 72%. Laparoscopy is a superior method for the result of tubal and pelvic pathologies in the evaluation of infertility. However, HSG is a more economical and elementary method suitable for evaluation of endometrial and tubal pathologies and laparoscopy is an appropriate method for examining the external part of tubae, fimbriae, the relation of tuba and ovary, endometriosis, adhesions, tuberculosis and other pathologies. Therefore, these 2 methods are not alternative but complementary. (author)

  8. Post-mortem virtual estimation of free abdominal blood volume

    International Nuclear Information System (INIS)

    Ampanozi, Garyfalia; Hatch, Gary M.; Ruder, Thomas D.; Flach, Patricia M.; Germerott, Tanja; Thali, Michael J.; Ebert, Lars C.

    2012-01-01

    Purpose: The purpose of this retrospective study was to examine the reliability of virtually estimated abdominal blood volume using segmentation from postmortem computed tomography (PMCT) data. Materials and methods: Twenty-one cases with free abdominal blood were investigated by PMCT and autopsy. The volume of the blood was estimated using a manual segmentation technique (Amira, Visage Imaging, Germany) and the results were compared to autopsy data. Six of 21 cases had undergone additional post-mortem computed tomographic angiography (PMCTA). Results: The virtually estimated abdominal blood volumes did not differ significantly from those measured at autopsy. Additional PMCTA did not bias data significantly. Conclusion: Virtual estimation of abdominal blood volume is a reliable technique. The virtual blood volume estimation is a useful tool to deliver additional information in cases where autopsy is not performed or in cases where a postmortem angiography is performed

  9. Virtual Bronchoscopy for Diagnosis of Recurrent Respiratory Papillomatosis

    Directory of Open Access Journals (Sweden)

    Chin-Hung Chang

    2006-01-01

    Full Text Available Virtual bronchoscopy is a new method for viewing helical/spiral computed tomography (CT images of the tracheobronchial trees. Using commercially available software to process the CT data, the tracheobronchial trees can be inspected through a series of three-dimensional images. Recently, this technique has been increasingly used to detect benign and malignant airway stenosis. We report the findings of virtual bronchoscopy in a 41-year-old man with recurrent respiratory papillomatosis (RRP. Several tiny nodules were evident in the lower trachea. Fiberoptic bronchoscopy was performed 1 month later during a planned surgery for laryngeal papillomas, and the findings were in agreement with virtual bronchoscopy. Detection of intrabronchial spreading in RRP is important since peripheral seeding of RRP can cause complications, including recurrent pneumonia, obstructive atelectasis, hemoptysis, and, rarely, may degenerate to squamous cell carcinoma. Virtual bronchoscopy is an alternative method for inspecting the tracheobronchial trees in patients with RRP when laryngeal papillomas impede fiberoptic bronchoscopy.

  10. computed tomography features of basal ganglia and periventricular

    African Journals Online (AJOL)

    HIV is probably the most common cause of basal ganglia and periventricular calcification today. on-enhanced computed tomography (NECT) shows diffuse cerebral atrophy in 90% of cases. Bilateral, symmetrical basal ganglia calcification is seen in 30% of cases, but virtually never before 1 year of age.1. CMV (FIG.2).

  11. Virtual reality simulator for vitreoretinal surgery using integrated OCT data

    Directory of Open Access Journals (Sweden)

    Kozak I

    2014-03-01

    Full Text Available Igor Kozak,1 Pat Banerjee,2 Jia Luo,2 Cristian Luciano21King Khaled Eye Specialist Hospital, Vitreoretinal Division, Riyadh, Kingdom of Saudi Arabia; 2College of Engineering, University of Illinois at Chicago, Chicago, IL, USAAbstract: Operative practice using surgical simulators has become a part of training in many surgical specialties, including ophthalmology. We introduce a virtual reality retina surgery simulator capable of integrating optical coherence tomography (OCT scans from real patients for practicing vitreoretinal surgery using different pathologic scenarios.Keywords: optical coherence tomography

  12. Ambient seismic noise tomography for exploration seismology at Valhall

    Science.gov (United States)

    de Ridder, S. A.

    2011-12-01

    Permanent ocean-bottom cables installed at the Valhall field can repeatedly record high quality active seismic surveys. But in the absence of active seismic shooting, passive data can be recorded and streamed to the platform in real time. Here I studied 29 hours of data using seismic interferometry. I generate omni-directional Scholte-wave virtual-sources at frequencies considered very-low in the exploration seismology community (0.4-1.75 Hz). Scholte-wave group arrival times are inverted using both eikonal tomography and straight-ray tomography. The top 100 m near-surface at Valhall contains buried channels about 100 m wide that have been imaged with active seismic. Images obtained by ASNT using eikonal tomography or straight-ray tomography both contain anomalies that match these channels. When continuous recordings are made in real-time, tomography images of the shallow subsurface can be formed or updated on a daily basis, forming a very low cost near-surface monitoring system using seismic noise.

  13. Virtual Planning and Intraoperative Navigation in Craniomaxillofacial Surgery

    Directory of Open Access Journals (Sweden)

    Jorge Guiñales

    2017-08-01

    Full Text Available Surgery planning assisted by computer represents one important example of the collaboration between surgeons and engineers. Virtual planning allows surgeons to pre-do the surgery by working over a virtual 3D model of the patient obtained through a computer tomography. Through surgical navigation, surgeons are helped while working with deep structures and can check if they are following accurately the surgical plan. These assistive tools are crucial in the field of facial reconstructive surgery. This paper describes two cases, one related to orbital fractures and another one related to oncological patients, showing the advantages that these tools provide, specifically when used for craniomaxillofacial surgery.

  14. Parsimonious Refraction Interferometry and Tomography

    KAUST Repository

    Hanafy, Sherif

    2017-02-04

    We present parsimonious refraction interferometry and tomography where a densely populated refraction data set can be obtained from two reciprocal and several infill shot gathers. The assumptions are that the refraction arrivals are head waves, and a pair of reciprocal shot gathers and several infill shot gathers are recorded over the line of interest. Refraction traveltimes from these shot gathers are picked and spawned into O(N2) virtual refraction traveltimes generated by N virtual sources, where N is the number of geophones in the 2D survey. The virtual traveltimes can be inverted to give the velocity tomogram. This enormous increase in the number of traveltime picks and associated rays, compared to the many fewer traveltimes from the reciprocal and infill shot gathers, allows for increased model resolution and a better condition number with the system of normal equations. A significant benefit is that the parsimonious survey and the associated traveltime picking is far less time consuming than that for a standard refraction survey with a dense distribution of sources.

  15. Hybrid rendering of the chest and virtual bronchoscopy [corrected].

    Science.gov (United States)

    Seemann, M D; Seemann, O; Luboldt, W; Gebicke, K; Prime, G; Claussen, C D

    2000-10-30

    Thin-section spiral computed tomography was used to acquire the volume data sets of the thorax. The tracheobronchial system and pathological changes of the chest were visualized using a color-coded surface rendering method. The structures of interest were then superimposed on a volume rendering of the other thoracic structures, thus producing a hybrid rendering. The hybrid rendering technique exploit the advantages of both rendering methods and enable virtual bronchoscopic examinations using different representation models. Virtual bronchoscopic examinations with a transparent color-coded shaded-surface model enables the simultaneous visualization of both the airways and the adjacent structures behind of the tracheobronchial wall and therefore, offers a practical alternative to fiberoptic bronchoscopy. Hybrid rendering and virtual endoscopy obviate the need for time consuming detailed analysis and presentation of axial source images.

  16. On proton CT reconstruction using MVCT-converted virtual proton projections

    Energy Technology Data Exchange (ETDEWEB)

    Wang Dongxu; Mackie, T. Rockwell; Tome, Wolfgang A. [Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin 53705 and Department of Radiation Oncology, University of Iowa Hospitals and Clinics, Iowa City, Iowa 52242 (United States); Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin 53705 and Morgridge Institute of Research, University of Wisconsin, Madison, Wisconsin 53715 (United States); Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin 53705 and Oncophysics Institute, Albert Einstein College of Medicine, Yeshiva University, Bronx, New York 10461 (United States)

    2012-06-15

    Purpose: To describe a novel methodology of converting megavoltage x-ray projections into virtual proton projections that are otherwise missing due to the proton range limit. These converted virtual proton projections can be used in the reconstruction of proton computed tomography (pCT). Methods: Relations exist between proton projections and multispectral megavoltage x-ray projections for human tissue. Based on these relations, these tissues can be categorized into: (a) adipose tissue; (b) nonadipose soft tissues; and (c) bone. These three tissue categories can be visibly identified on a regular megavoltage x-ray computed tomography (MVCT) image. With an MVCT image and its projection data available, the x-ray projections through heterogeneous anatomy can be converted to the corresponding proton projections using predetermined calibration curves for individual materials, aided by a coarse segmentation on the x-ray CT image. To show the feasibility of this approach, mathematical simulations were carried out. The converted proton projections, plotted on a proton sinogram, were compared to the simulated ground truth. Proton stopping power images were reconstructed using either the virtual proton projections only or a blend of physically available proton projections and virtual proton projections that make up for those missing due to the range limit. These images were compared to a reference image reconstructed from theoretically calculated proton projections. Results: The converted virtual projections had an uncertainty of {+-}0.8% compared to the calculated ground truth. Proton stopping power images reconstructed using a blend of converted virtual projections (48%) and physically available projections (52%) had an uncertainty of {+-}0.86% compared with that reconstructed from theoretically calculated projections. Reconstruction solely from converted virtual proton projections had an uncertainty of {+-}1.1% compared with that reconstructed from theoretical projections

  17. On proton CT reconstruction using MVCT-converted virtual proton projections

    International Nuclear Information System (INIS)

    Wang Dongxu; Mackie, T. Rockwell; Tomé, Wolfgang A.

    2012-01-01

    Purpose: To describe a novel methodology of converting megavoltage x-ray projections into virtual proton projections that are otherwise missing due to the proton range limit. These converted virtual proton projections can be used in the reconstruction of proton computed tomography (pCT). Methods: Relations exist between proton projections and multispectral megavoltage x-ray projections for human tissue. Based on these relations, these tissues can be categorized into: (a) adipose tissue; (b) nonadipose soft tissues; and (c) bone. These three tissue categories can be visibly identified on a regular megavoltage x-ray computed tomography (MVCT) image. With an MVCT image and its projection data available, the x-ray projections through heterogeneous anatomy can be converted to the corresponding proton projections using predetermined calibration curves for individual materials, aided by a coarse segmentation on the x-ray CT image. To show the feasibility of this approach, mathematical simulations were carried out. The converted proton projections, plotted on a proton sinogram, were compared to the simulated ground truth. Proton stopping power images were reconstructed using either the virtual proton projections only or a blend of physically available proton projections and virtual proton projections that make up for those missing due to the range limit. These images were compared to a reference image reconstructed from theoretically calculated proton projections. Results: The converted virtual projections had an uncertainty of ±0.8% compared to the calculated ground truth. Proton stopping power images reconstructed using a blend of converted virtual projections (48%) and physically available projections (52%) had an uncertainty of ±0.86% compared with that reconstructed from theoretically calculated projections. Reconstruction solely from converted virtual proton projections had an uncertainty of ±1.1% compared with that reconstructed from theoretical projections. If

  18. X-ray computed tomography for virtually unrolling damaged papyri

    Energy Technology Data Exchange (ETDEWEB)

    Allegra, Dario; Ciliberto, Paolo; Stanco, Filippo [Universita degli Studi di Catania, Dipartimento di Matematica ed Informatica, Catania (Italy); Ciliberto, Enrico [Universita degli Studi di Catania, Dipartimento di Scienze Chimiche, Catania (Italy); Petrillo, Giuseppe; Trombatore, Claudia [Universita degli Studi di Catania, Dipartimento di Scienze Mediche Chirurgiche e Tecnologie Avanzate, Catania (Italy)

    2016-03-15

    The regular format for ancient works of literature was the papyrus roll. Recently many efforts to perform virtual restoration of this archeological artifact have been done. In fact the case of ancient rolled papyrus is very intriguing. Old papyruses are the substrates of very important historical information, probably being the use of papyrus dated to the Pre-Dynastic Period. Papyrus degradation is often very hard so that physical unrolling is sometime absolutely impossible. In this paper, authors describe their effort in setting a new virtual restoration methodology based on software manipulation of X-ray tomographic images. A realistic model, obtained by painting a hieroglyph inscription of Thutmosis III on a papyrus substrate made by the original method described by Plinius the Elder and by pigments and binders compatible with the Egyptian use (ochers with natural glue), was made for the X-ray investigation. A GE Optima 660 64 slice was used to obtain a stack of tomographic slices of the rolled model. Each slice appears as spiral. The intensity variations along the cross-sectional result from ink on the papyrus. The files were elaborated with original software, written by the use of MATLAB high-level language, and the final result was quite similar to the radiography of the physically unrolled sheet. (orig.)

  19. X-ray computed tomography for virtually unrolling damaged papyri

    Science.gov (United States)

    Allegra, Dario; Ciliberto, Enrico; Ciliberto, Paolo; Petrillo, Giuseppe; Stanco, Filippo; Trombatore, Claudia

    2016-03-01

    The regular format for ancient works of literature was the papyrus roll. Recently many efforts to perform virtual restoration of this archeological artifact have been done. In fact the case of ancient rolled papyrus is very intriguing. Old papyruses are the substrates of very important historical information, probably being the use of papyrus dated to the Pre-Dynastic Period. Papyrus degradation is often very hard so that physical unrolling is sometime absolutely impossible. In this paper, authors describe their effort in setting a new virtual restoration methodology based on software manipulation of X-ray tomographic images. A realistic model, obtained by painting a hieroglyph inscription of Thutmosis III on a papyrus substrate made by the original method described by Plinius the Elder and by pigments and binders compatible with the Egyptian use (ochers with natural glue), was made for the X-ray investigation. A GE Optima 660 64 slice was used to obtain a stack of tomographic slices of the rolled model. Each slice appears as spiral. The intensity variations along the cross-sectional result from ink on the papyrus. The files were elaborated with original software, written by the use of MATLAB high-level language, and the final result was quite similar to the radiography of the physically unrolled sheet.

  20. X-ray computed tomography for virtually unrolling damaged papyri

    International Nuclear Information System (INIS)

    Allegra, Dario; Ciliberto, Paolo; Stanco, Filippo; Ciliberto, Enrico; Petrillo, Giuseppe; Trombatore, Claudia

    2016-01-01

    The regular format for ancient works of literature was the papyrus roll. Recently many efforts to perform virtual restoration of this archeological artifact have been done. In fact the case of ancient rolled papyrus is very intriguing. Old papyruses are the substrates of very important historical information, probably being the use of papyrus dated to the Pre-Dynastic Period. Papyrus degradation is often very hard so that physical unrolling is sometime absolutely impossible. In this paper, authors describe their effort in setting a new virtual restoration methodology based on software manipulation of X-ray tomographic images. A realistic model, obtained by painting a hieroglyph inscription of Thutmosis III on a papyrus substrate made by the original method described by Plinius the Elder and by pigments and binders compatible with the Egyptian use (ochers with natural glue), was made for the X-ray investigation. A GE Optima 660 64 slice was used to obtain a stack of tomographic slices of the rolled model. Each slice appears as spiral. The intensity variations along the cross-sectional result from ink on the papyrus. The files were elaborated with original software, written by the use of MATLAB high-level language, and the final result was quite similar to the radiography of the physically unrolled sheet. (orig.)

  1. Clinical applications of imaging reconstruction by virtual sonography

    International Nuclear Information System (INIS)

    Mori, Akihiro; Oohashi, Noritsugu; Maruyama, Takako; Tatebe, Hideharu; Fushimi, Nobutoshi; Asano, Takayuki; Inoue, Hiroshi; Okuno, Masataka

    2008-01-01

    One of the pitfalls in managing multiple liver tumors is the difficulty in identifying individual tumors on ultrasonography. Computed tomography (CT)-assisted virtual sonography has been shown to improve sonographic diagnosis, however it requires additional equipment and software. We have developed a simple reconstruction method of virtual sonography (SRVS). We reconstructed SRVS mimicking ultrasonographic images, utilizing a workstation software attached to a multi-detector row CT system without any additional program. We have performed SRVS in 32 patients with 41 liver tumors that could hardly be identify on ultrasonography. SRVS assisted the identification of malignant form non-pathologic ones and thereby contributed to the appropriate clinical strategy including radiofrequency ablation (RFA) (18 tumors), liver biopsy (2 tumors), other therapies (4 tumors) and follow-up (17 tumors). We have developed virtual sonography using conventional CT software. SRVS seems useful in the clinical practice in managing liver tumors. (author)

  2. Software for simulation of a computed tomography imaging spectrometer using optical design software

    Science.gov (United States)

    Spuhler, Peter T.; Willer, Mark R.; Volin, Curtis E.; Descour, Michael R.; Dereniak, Eustace L.

    2000-11-01

    Our Imaging Spectrometer Simulation Software known under the name Eikon should improve and speed up the design of a Computed Tomography Imaging Spectrometer (CTIS). Eikon uses existing raytracing software to simulate a virtual instrument. Eikon enables designers to virtually run through the design, calibration and data acquisition, saving significant cost and time when designing an instrument. We anticipate that Eikon simulations will improve future designs of CTIS by allowing engineers to explore more instrument options.

  3. Emission tomography for adrenal imaging

    International Nuclear Information System (INIS)

    Britton, K.E.; Shapiro, B.; Hawkins, L.A.

    1980-01-01

    Single photon emission tomography (SPET) of the adrenals was compared to convential gamma camera images. Depths of 19 adrenals were assessed by both the lateral skin-upper kidney pole method and by SPET. Eleven patients with adrenal disorders were also studied. An advantage of using SPET was that the analogue transverse section image showed improvement over the conventional posterior view because the liver activity was well separated from the adrenal. Furthermore, non-adrenal tissue background was virtually eliminated and adrenal depth determination facilitated. (U.K.)

  4. X-ray microtome by fluorescence tomography

    CERN Document Server

    Simionovici, A S; Guenzler, F; Schrör, C; Snigirev, A; Snigireva, I; Tümmler, J; Weitkamp, T

    2001-01-01

    The X-ray fluorescence microtomography method is presented, which is capable of virtually slicing samples to obtain cross-sections of their inner structure. High precision experimental results of fluo-tomography in 'pencil-beam' geometry with up to 1.2 mu m resolution are described. Image reconstructions are based on either a simplified algebraic reconstruction method (ART) or the filtered back-projection method (FBP). Phantoms of inhomogeneous test objects as well as biological samples are successfully analyzed.

  5. Material decomposition and virtual non-contrast imaging in photon counting computed tomography: an animal study

    Science.gov (United States)

    Gutjahr, R.; Polster, C.; Kappler, S.; Pietsch, H.; Jost, G.; Hahn, K.; Schöck, F.; Sedlmair, M.; Allmendinger, T.; Schmidt, B.; Krauss, B.; Flohr, T. G.

    2016-03-01

    The energy resolving capabilities of Photon Counting Detectors (PCD) in Computed Tomography (CT) facilitate energy-sensitive measurements. The provided image-information can be processed with Dual Energy and Multi Energy algorithms. A research PCD-CT firstly allows acquiring images with a close to clinical configuration of both the X-ray tube and the CT-detector. In this study, two algorithms (Material Decomposition and Virtual Non-Contrast-imaging (VNC)) are applied on a data set acquired from an anesthetized rabbit scanned using the PCD-CT system. Two contrast agents (CA) are applied: A gadolinium (Gd) based CA used to enhance contrasts for vascular imaging, and xenon (Xe) and air as a CA used to evaluate local ventilation of the animal's lung. Four different images are generated: a) A VNC image, suppressing any traces of the injected Gd imitating a native scan, b) a VNC image with a Gd-image as an overlay, where contrast enhancements in the vascular system are highlighted using colored labels, c) another VNC image with a Xe-image as an overlay, and d) a 3D rendered image of the animal's lung, filled with Xe, indicating local ventilation characteristics. All images are generated from two images based on energy bin information. It is shown that a modified version of a commercially available dual energy software framework is capable of providing images with diagnostic value obtained from the research PCD-CT system.

  6. Virtual reality and anthropology

    International Nuclear Information System (INIS)

    Recheis, Wolfgang; Weber, Gerhard W.; Schaefer, Katrin; Knapp, Rudolf; Seidler, Horst; Zur Nedden, Dieter

    1999-01-01

    Since the discovery of the Tyrolean Iceman in 1991 advanced imaging and post processing techniques were successfully applied in anthropology. Specific techniques include spiral computed tomography and 3-dimensional reconstructions including stereolithographic and fused deposition modeling of volume data sets. The Iceman's skull was the first to be reproduced using stereolithography, before this method was successfully applied in preoperative planning. With the advent of high-end graphics workstations and biomedical image processing software packages, 3-dimensional reconstructions were established as a routine tool for analyzing volume data sets. These techniques opened totally new insights in the field of physical anthropology. Computed tomography became the ideal research tool to access the internal structures of various precious fossils without damaging or even touching them. Many of the most precious specimens from the species Autralopithecus (1.8-3.5 Myears), Homo heidelbergensis (200-600 kyears) or Homo neanderthalensis (40-100 kyears) were scanned during the last 5 years. Often the fossils are filled with a stone matrix or other materials. During the postprocessing routines highly advanced algorithms were used to remove virtually these incrustations. Thus it was possible to visualize the morphological structures that lie beneath the matrix. Some specimens were partially destroyed, so the missing parts were reconstructed on computer screen in order to get estimations of the brain volume and endocranial morphology, both major fields of interest in physical anthropology. Moreover the computerized form of the data allows new descriptions of morphologic structures by the means of 'geometric morphometrics'. Some of the results may change aspects and interpretations in human evolution. The introduction of new imaging and post processing techniques created a new field of research: Virtual Anthropology

  7. Comparisons of Hysterosalpingography and Laparoscopy Results in the Diagnosis of Tubal Occlusion

    Directory of Open Access Journals (Sweden)

    Rafet Duraker

    2011-03-01

    Full Text Available Objective: The compliance rate between the hysterosalpingography (HSG and laparoscopy (L/S results in patients who diagnosed tubal occlusion on the HSG was investigated. Also, the incidence of endometriosis was evaluated in the study population. Material and Methods: Medical records of 139 women who were underwent L/S for the investigation of the tubal occlusion were reviewed retrospectively. The concordance rate between the HSG and L/S was investigated. The incidence of endometriosis in patients with no tubal pathology was compared with patients with unilaterally and bilaterally tubal occlusion. Results: Mean age of the women was 31.8±5.7years, mean BMI was measured as 24.6±4.6 kg/m2, and gravida 0 (0-5, mean infertility period was 30.7±3.7 months. Tubal occlusion was confirmed after the L/S in 38.8% of the patients (n=38 who has unilaterally tubal occlusion on the HSG. However, 58.8% (n=20 of the patients who were diagnosed as bilaterally tubal occlusion on the HSG was confirmed with the L/S. The misdiagnosis rate of the HSG was significantly high in women with unilaterally tubal occlusions compared with bilaterally tubal occlusions [(respectively, 61.2%, 51.2% (p: 0.001]. Endometriosis was observed in 28.4% of the patients who had patent tubes and in 13.9% of the patients in the unilaterally tubal occlusion group and and in 22.7% of the patients in the bilaterally tubal occlusion group. But the difference was not statistically significant when groups were compared according to the rate of endometriosis (p=0.24. Conclusion: HSG is the first step diagnostic test for the assessment of the fallopian tubes. Although L/S is more invasive technique than HSG, L/S with chromopertubation is the gold standard test for identifying periadnexal adhesive disease and endometriosis.

  8. Three-dimensional treatment planning of orthognathic surgery in the era of virtual imaging.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mollemans, W.; Schutyser, F.A.C.

    2009-01-01

    PURPOSE: The aim of this report was to present an integrated 3-dimensional (3D) virtual approach toward cone-beam computed tomography-based treatment planning of orthognathic surgery in the clinical routine. MATERIALS AND METHODS: We have described the different stages of the workflow process for

  9. Application of computed tomography virtual noncontrast spectral imaging in evaluation of hepatic metastases: a preliminary study.

    Science.gov (United States)

    Tian, Shi-Feng; Liu, Ai-Lian; Liu, Jing-Hong; Sun, Mei-Yu; Wang, He-Qing; Liu, Yi-Jun

    2015-03-05

    The objective was to qualitatively and quantitatively evaluate hepatic metastases using computed tomography (CT) virtual noncontrast (VNC) spectral imaging in a retrospective analysis. Forty hepatic metastases patients underwent CT scans including the conventional true noncontrast (TNC) and the tri-phasic contrast-enhanced dual energy spectral scans in the hepatic arterial, portal venous, and equilibrium phases. The tri-phasic spectral CT images were used to obtain three groups of VNC images including in the arterial (VNCa), venous (VNCv), and equilibrium (VNCe) phase by the material decomposition process using water and iodine as a base material pair. The image quality and the contrast-to-noise ratio (CNR) of metastasis of the four groups were compared with ANOVA analysis. The metastasis detection rates with the four nonenhanced image groups were calculated and compared using the Chi-square test. There were no significant differences in image quality among TNC, VNCa and VNCv images (P > 0.05). The quality of VNCe images was significantly worse than that of other three groups (P 0.05). The metastasis detection rate of the four nonenhanced groups with no statistically significant difference (P > 0.05). The quality of VNCa and VNCv images is identical to that of TNC images, and the metastasis detection rate in VNC images is similar to that in TNC images. VNC images obtained from arterial phase show metastases more clearly. Thus, VNCa imaging may be a surrogate to TNC imaging in hepatic metastasis diagnosis.

  10. Application of Computed Tomography Virtual Noncontrast Spectral Imaging in Evaluation of Hepatic Metastases: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Shi-Feng Tian

    2015-01-01

    Full Text Available Objective: The objective was to qualitatively and quantitatively evaluate hepatic metastases using computed tomography (CT virtual noncontrast (VNC spectral imaging in a retrospective analysis. Methods: Forty hepatic metastases patients underwent CT scans including the conventional true noncontrast (TNC and the tri-phasic contrast-enhanced dual energy spectral scans in the hepatic arterial, portal venous, and equilibrium phases. The tri-phasic spectral CT images were used to obtain three groups of VNC images including in the arterial (VNCa, venous (VNCv, and equilibrium (VNCe phase by the material decomposition process using water and iodine as a base material pair. The image quality and the contrast-to-noise ratio (CNR of metastasis of the four groups were compared with ANOVA analysis. The metastasis detection rates with the four nonenhanced image groups were calculated and compared using the Chi-square test. Results: There were no significant differences in image quality among TNC, VNCa and VNCv images (P > 0.05. The quality of VNCe images was significantly worse than that of other three groups (P 0.05. The metastasis detection rate of the four nonenhanced groups with no statistically significant difference (P > 0.05. Conclusions: The quality of VNCa and VNCv images is identical to that of TNC images, and the metastasis detection rate in VNC images is similar to that in TNC images. VNC images obtained from arterial phase show metastases more clearly. Thus, VNCa imaging may be a surrogate to TNC imaging in hepatic metastasis diagnosis.

  11. Immersive Virtual Reality for Visualization of Abdominal CT.

    Science.gov (United States)

    Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A; Bodenheimer, Robert E

    2013-03-28

    Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two-dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.

  12. Immersive virtual reality for visualization of abdominal CT

    Science.gov (United States)

    Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A.; Bodenheimer, Robert E.

    2013-03-01

    Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.

  13. Automated method for structural segmentation of nasal airways based on cone beam computed tomography

    Science.gov (United States)

    Tymkovych, Maksym Yu.; Avrunin, Oleg G.; Paliy, Victor G.; Filzow, Maksim; Gryshkov, Oleksandr; Glasmacher, Birgit; Omiotek, Zbigniew; DzierŻak, RóŻa; Smailova, Saule; Kozbekova, Ainur

    2017-08-01

    The work is dedicated to the segmentation problem of human nasal airways using Cone Beam Computed Tomography. During research, we propose a specialized approach of structured segmentation of nasal airways. That approach use spatial information, symmetrisation of the structures. The proposed stages can be used for construction a virtual three dimensional model of nasal airways and for production full-scale personalized atlases. During research we build the virtual model of nasal airways, which can be used for construction specialized medical atlases and aerodynamics researches.

  14. Virtual planning of dental implant placement using CT double scan-technique - own experience

    International Nuclear Information System (INIS)

    Wojciechowski, W.; Urbanik, A.; Kownacki, P.; Kownacki, S.

    2007-01-01

    The correctness of CT performed with the use of a double-scan technique is the basis for achieving proper quality of 3D reconstructions of the maxilla or mandible and subsequent virtual planning of dental implant placement. The aim of this study was the presentation of the methodology of computed tomography scanning and own experience with the use of the double-scan technique. The study group included 26 individuals who underwent MDCT with a double-scan technique using a MDCT scanner SOMATOM Sensation (Siemens, Germany). The parameters of the examination: slice-collimation 10 x 0.75 mm, slice-thickness 0.75 mm. The first CT scan in the procedure was the scan of the patient wearing a radiological prosthesis and occlusal index, which was followed by a separate scan of the radiological prosthesis. These two CT scans were copied and transferred to PC with Procera Software program (Nobel Biocare, Sweden) where dental implant placement was virtually planned. In all 26 patients, precise three-dimensional reconstructions of the anatomical structure were obtained. In 11 patients, on the basis of the virtual planning, the implant placement was performed, 5 patients were referred to preparatory procedures, that is, restoration of the alveolar process, otolaryngological treatment of the maxillary sinuses. The remaining 10 patients did not qualify to the procedure because of unfavorable anatomical ideation's. Correct computed tomography with double-scan technique enables virtual planning of dental implant placement, on the basis of which the real procedure of implantation can be performed. (author)

  15. Clinical applications of virtual navigation bronchial intervention.

    Science.gov (United States)

    Kajiwara, Naohiro; Maehara, Sachio; Maeda, Junichi; Hagiwara, Masaru; Okano, Tetsuya; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2018-01-01

    In patients with bronchial tumors, we frequently consider endoscopic treatment as the first treatment of choice. All computed tomography (CT) must satisfy several conditions necessary to analyze images by Synapse Vincent. To select safer and more precise approaches for patients with bronchial tumors, we determined the indications and efficacy of virtual navigation intervention for the treatment of bronchial tumors. We examined the efficacy of virtual navigation bronchial intervention for the treatment of bronchial tumors located at a variety of sites in the tracheobronchial tree using a high-speed 3-dimensional (3D) image analysis system, Synapse Vincent. Constructed images can be utilized to decide on the simulation and interventional strategy as well as for navigation during interventional manipulation in two cases. Synapse Vincent was used to determine the optimal planning of virtual navigation bronchial intervention. Moreover, this system can detect tumor location and alsodepict surrounding tissues, quickly, accurately, and safely. The feasibility and safety of Synapse Vincent in performing useful preoperative simulation and navigation of surgical procedures can lead to safer, more precise, and less invasion for the patient, and makes it easy to construct an image, depending on the purpose, in 5-10 minutes using Synapse Vincent. Moreover, if the lesion is in the parenchyma or sub-bronchial lumen, it helps to perform simulation with virtual skeletal subtraction to estimate potential lesion movement. By using virtual navigation system for simulation, bronchial intervention was performed with no complications safely and precisely. Preoperative simulation using virtual navigation bronchial intervention reduces the surgeon's stress levels, particularly when highly skilled techniques are needed to operate on lesions. This task, including both preoperative simulation and intraoperative navigation, leads to greater safety and precision. These technological instruments

  16. Study on multi-detector computed tomography in the virtual endoscope mode to phantom of saliva gland duct application. Image quality evaluation of geometry

    International Nuclear Information System (INIS)

    Ozawa, Tomonori; Innami, Hisashi; Oyake, Reira; Shinohara, Yuki; Yamaaki, Fumi; Koizumi, Nobuhide; Okumura, Yasuhiko

    2009-01-01

    The diagnosis ability of the radiographic imaging has been greatly improved by the advent of multi-detector computed tomography (MDCT), Which is now a the prerequisite to the diagnosis and treatment of a variety of diseases. MDCT conducted in the virtual endoscope mode can be used for various image compositions, and the space in a structure such as the large intestines can be visualized similarly as with an actual endoscope. Using a phantom of a salivary gland duct, I performed the image analysis to determine whether this endoscope mode could able to be applied to the oral cavity. I searched for the optimum conditions and the best position for taking pictures, and evaluated whether the salivary gland ducts could be reproducibly imitated by the phantom. Modulation transfer function (MTF), Wiener spectrum (WS) analysis were used to examined the utility of MDCT in the virtual endoscope mode for use in the oral cavity. As a result, the following conclusions were made: The best image was obtained within 40 mm from the center part of the gantry by the MTF and the WS analyses. Decreases in the MTF and the WS as the decrease were seen at 20 mAs and 80 kV, and the decrease were seen in the sharpness of the image decreased as the value of the reconstruction function became smaller. The image was somewhat distorted when pictures were taken of the parallel or the direction of the slice by the inclination within 90 deg±15 deg as much as possible Z axially for running of the duct in the evaluation of internal reproducibility. The influence was admitted to go out easily in an inside form as the inside diameter became thin. The salivary gland phantom was evaluated geometrically by MDCT in the virtual endoscope mode, and the optimal conditions were obtained from the above-mentioned results. The utility of MDCT in the mode was thus suggested. (author)

  17. Virtual reality in advanced medical immersive imaging: a workflow for introducing virtual reality as a supporting tool in medical imaging

    KAUST Repository

    Knodel, Markus M.

    2018-02-27

    Radiologic evaluation of images from computed tomography (CT) or magnetic resonance imaging for diagnostic purposes is based on the analysis of single slices, occasionally supplementing this information with 3D reconstructions as well as surface or volume rendered images. However, due to the complexity of anatomical or pathological structures in biomedical imaging, innovative visualization techniques are required to display morphological characteristics three dimensionally. Virtual reality is a modern tool of representing visual data, The observer has the impression of being “inside” a virtual surrounding, which is referred to as immersive imaging. Such techniques are currently being used in technical applications, e.g. in the automobile industry. Our aim is to introduce a workflow realized within one simple program which processes common image stacks from CT, produces 3D volume and surface reconstruction and rendering, and finally includes the data into a virtual reality device equipped with a motion head tracking cave automatic virtual environment system. Such techniques have the potential to augment the possibilities in non-invasive medical imaging, e.g. for surgical planning or educational purposes to add another dimension for advanced understanding of complex anatomical and pathological structures. To this end, the reconstructions are based on advanced mathematical techniques and the corresponding grids which we can export are intended to form the basis for simulations of mathematical models of the pathogenesis of different diseases.

  18. Aspects of pulmonary histiocytosis X on high resolution computed tomography

    International Nuclear Information System (INIS)

    Costa, N.S.S.; Castro Lessa Angela, M.T. de; Angelo Junior, J.R.L.; Silva, F.M.D.; Kavakama, J.; Carvalho, C.R.R. de; Cerri, G.G.

    1995-01-01

    Pulmonary histiocytosis X is a disease that occurs in young adults and presents with nodules and cysts, mainly in upper lobes, with consequent pulmonary fibrosis. These pulmonary changes are virtually pathognomonic findings on high resolution computed tomography, that allows estimate the area of the lung involved and distinguish histiocytosis X from other disorders that also produces nodules and cysts. (author). 10 refs, 2 tabs, 6 figs

  19. Virtually teaching virtual leadership

    DEFF Research Database (Denmark)

    Henriksen, Thomas Duus; Nielsen, Rikke Kristine; Børgesen, Kenneth

    2017-01-01

    This paper seeks to investigate the challenges to virtual collaboration and leadership on basis of findings from a virtual course on collaboration and leadership. The course used for this experiment was designed as a practical approach, which allowed participants to experience curriculum phenomena....... This experimental course provided insights into the challenges involved in virtual processes, and those experiences where used for addressing the challenges that virtual leadership is confronted with. Emphasis was placed on the reduction of undesired virtual distance and its consequences through affinity building....... We found that student scepticism appeared when a breakdown resulted in increasing virtual distance, and raises questions on how leaders might translate or upgrade their understandings of leadership to handling such increased distance through affinity building....

  20. Tomography for two-dimensional gas temperature distribution based on TDLAS

    Science.gov (United States)

    Luo, Can; Wang, Yunchu; Xing, Fei

    2018-03-01

    Based on tunable diode laser absorption spectroscopy (TDLAS), the tomography is used to reconstruct the combustion gas temperature distribution. The effects of number of rays, number of grids, and spacing of rays on the temperature reconstruction results for parallel ray are researched. The reconstruction quality is proportional to the ray number. The quality tends to be smoother when the ray number exceeds a certain value. The best quality is achieved when η is between 0.5 and 1. A virtual ray method combined with the reconstruction algorithms is tested. It is found that virtual ray method is effective to improve the accuracy of reconstruction results, compared with the original method. The linear interpolation method and cubic spline interpolation method, are used to improve the calculation accuracy of virtual ray absorption value. According to the calculation results, cubic spline interpolation is better. Moreover, the temperature distribution of a TBCC combustion chamber is used to validate those conclusions.

  1. Examination of the effect of ovarian radiation injury induced by hysterosalpingography on ovarian proliferating cell nuclear antigen and the radioprotective effect of amifostine: an experimental study

    Directory of Open Access Journals (Sweden)

    Can B

    2018-05-01

    Full Text Available Behzat Can,1 Remzi Atilgan,1 Sehmus Pala,1 Tuncay Kuloğlu,2 Sule Kiray,3 Nevin Ilhan4 1Department of Obstetrics and Gynecology, Firat University School of Medicine, Elazig, Turkey; 2Department of Histology and Embryology, Firat University School of Medicine, Elazig, Turkey; 3Department of Obstetrics and Gynecology, Maltepe University School of Medicine, Istanbul, Turkey; 4Department of Biochemistry, Firat University School of Medicine, Elazig, Turkey Aim: The aim of this study was to examine the effect of amifostine on cellular injury in the ovarian tissue induced by hysterosalpingography (HSG.Methods: In total, forty 4-month old female Wistar Albino rats were assigned into 8 groups. Each group contained 5 rats. Group 1 (G1: rats were decapitated without any procedure. Group 2 (G2: rats were decapitated after 3 hours of total body irradiation. Group 3 (G3: rats were decapitated 3 hours after HSG procedure. Group 4 (G4: rats were decapitated 3 hours after HSG procedure performed 30 min after receiving amifostine 200 mg/kg intraperitoneally. Group 5 (G5: rats were decapitated after 1 month without any procedure. Group 6 (G6: rats were decapitated after 1 month of total body irradiation. Group 7 (G7: rats were decapitated 1 month after HSG procedure. Group 8 (G8: rats were decapitated 1 month after HSG procedure performed 30 min after receiving amifostine 200 mg/kg intraperitoneally. After rats were decapitated under general anesthesia in all groups, blood samples were obtained and bilateral ovaries were removed. One of the ovaries was placed in 10% formaldehyde solution for histological germinal epithelial degeneration, apoptosis and proliferating cell nuclear antigen scoring. The other ovary and blood sera were stored at –80°C. TNF-α, total antioxidant status, total oxidant status, and malondialdehyde levels were studied in tissue samples and anti-mullerian hormone levels in blood samples.Results: At the end of the first month, there was

  2. Virtual non-contrast computer tomography (CT) with spectral CT as an alternative to conventional unenhanced CT in the assessment of gastric cancer.

    Science.gov (United States)

    Tian, Shi-Feng; Liu, Ai-Lian; Wang, He-Qing; Liu, Jing-Hong; Sun, Mei-Yu; Liu, Yi-Jun

    2015-01-01

    The purpose of this study was to evaluate computed tomography (CT) virtual non-contrast (VNC) spectral imaging for gastric carcinoma. Fifty-two patients with histologically proven gastric carcinomas underwent gemstone spectral imaging (GSI) including non-contrast and contrast-enhanced hepatic arterial, portal venous, and equilibrium phase acquisitions prior to surgery. VNC arterial phase (VNCa), VNC venous phase (VNCv), and VNC equilibrium phase (VNCe) images were obtained by subtracting iodine from iodine/water images. Images were analyzed with respect to image quality, gastric carcinoma-intragastric water contrast-to-noise ratio (CNR), gastric carcinoma-perigastric fat CNR, serosal invasion, and enlarged lymph nodes around the lesions. Carcinoma-water CNR values were significantly higher in VNCa, VNCv, and VNCe images than in normal CT images (2.72, 2.60, 2.61, respectively, vs 2.35, p≤0.008). Carcinoma- perigastric fat CNR values were significantly lower in VNCa, VNCv, and VNCe images than in normal CT images (7.63, 7.49, 7.32, respectively, vs 8.48, pVNC arterial phase images may be a surrogate for conventional non-contrast CT images in gastric carcinoma evaluation.

  3. Usefulness of Computed Tomography in pre-surgical evaluation of maxillo-facial pathology with rapid prototyping and surgical pre-planning by virtual reality

    International Nuclear Information System (INIS)

    Toso, Francesco; Zuiani, Chiara; Vergendo, Maurizio; Bazzocchi, Massimo; Salvo, Iolanda; Robiony, Massimo; Politi, Massimo

    2005-01-01

    Purpose. To validate a protocol for creating virtual models to be used in the construction of solid prototypes useful for the planning-simulation of maxillo-facial surgery, in particular for very complex anatomical and pathologic problems. To optimize communications between the radiology, engineering and surgical laboratories. Methods and materials. We studied 16 patients with different clinical problems of the maxillo-facial district. Exams were performed with multidetector computed tomography (MDCT) and single slice computed tomography (SDCT) with axial scans and collimation of 0.5-2 mm, and reconstruction interval of 1 mm. Subsequently we performed 2D multiplanar reconstructions and 3D volume-rendering reconstructions. We exported the DICOM images to the engineering laboratory, to recognize and isolate the bony structures by software. With these data the solid prototypes were generated using stereolitography. To date, surgery has been preformed on 12 patients after simulation of the procedure on the stereolitography model. Results. The solid prototypes constructed in the difficult cases were sufficiently detailed despite problems related to the artefacts generated by dental fillings and prostheses. In the remaining cases the MPR/3D images were sufficiently detailed for surgical planning. The surgical results were excellent in all patients who underwent surgery, and the surgeons were satisfied with the improvement in quality and the reduction in time required for the procedure. Conclusions. MDCT enables rapid prototyping using solid replication, which was very helpful in maxillofacial surgery, despite problems related to artifacts due to dental fillings and prosthesis within the acquisition field; solutions for this problem are work in progress. The protocol used for communication between the different laboratories was valid and reproducible [it

  4. Virtual reality simulator for vitreoretinal surgery using integrated OCT data

    OpenAIRE

    Kozak, Igor; Banerjee,Pat; Luo,Jia; Luciano,Cristian

    2014-01-01

    Igor Kozak,1 Pat Banerjee,2 Jia Luo,2 Cristian Luciano21King Khaled Eye Specialist Hospital, Vitreoretinal Division, Riyadh, Kingdom of Saudi Arabia; 2College of Engineering, University of Illinois at Chicago, Chicago, IL, USAAbstract: Operative practice using surgical simulators has become a part of training in many surgical specialties, including ophthalmology. We introduce a virtual reality retina surgery simulator capable of integrating optical coherence tomography (OCT) scans from real p...

  5. Micro-tomography based Geometry Modeling of Three-Dimensional Braided Composites

    Science.gov (United States)

    Fang, Guodong; Chen, Chenghua; Yuan, Shenggang; Meng, Songhe; Liang, Jun

    2018-06-01

    A tracking and recognizing algorithm is proposed to automatically generate irregular cross-sections and central path of braid yarn within the 3D braided composites by using sets of high resolution tomography images. Only the initial cross-sections of braid yarns in a tomography image after treatment are required to be calibrated manually as searching cross-section template. The virtual geometry of 3D braided composites including some detailed geometry information, such as the braid yarn squeezing deformation, braid yarn distortion and braid yarn path deviation etc., can be reconstructed. The reconstructed geometry model can reflect the change of braid configurations during solidification process. The geometry configurations and mechanical properties of the braided composites are analyzed by using the reconstructed geometry model.

  6. Stereoscopic virtual reality models for planning tumor resection in the sellar region

    Directory of Open Access Journals (Sweden)

    Wang Shou-sen

    2012-11-01

    Full Text Available Abstract Background It is difficult for neurosurgeons to perceive the complex three-dimensional anatomical relationships in the sellar region. Methods To investigate the value of using a virtual reality system for planning resection of sellar region tumors. The study included 60 patients with sellar tumors. All patients underwent computed tomography angiography, MRI-T1W1, and contrast enhanced MRI-T1W1 image sequence scanning. The CT and MRI scanning data were collected and then imported into a Dextroscope imaging workstation, a virtual reality system that allows structures to be viewed stereoscopically. During preoperative assessment, typical images for each patient were chosen and printed out for use by the surgeons as references during surgery. Results All sellar tumor models clearly displayed bone, the internal carotid artery, circle of Willis and its branches, the optic nerve and chiasm, ventricular system, tumor, brain, soft tissue and adjacent structures. Depending on the location of the tumors, we simulated the transmononasal sphenoid sinus approach, transpterional approach, and other approaches. Eleven surgeons who used virtual reality models completed a survey questionnaire. Nine of the participants said that the virtual reality images were superior to other images but that other images needed to be used in combination with the virtual reality images. Conclusions The three-dimensional virtual reality models were helpful for individualized planning of surgery in the sellar region. Virtual reality appears to be promising as a valuable tool for sellar region surgery in the future.

  7. Virtual goods recommendations in virtual worlds.

    Science.gov (United States)

    Chen, Kuan-Yu; Liao, Hsiu-Yu; Chen, Jyun-Hung; Liu, Duen-Ren

    2015-01-01

    Virtual worlds (VWs) are computer-simulated environments which allow users to create their own virtual character as an avatar. With the rapidly growing user volume in VWs, platform providers launch virtual goods in haste and stampede users to increase sales revenue. However, the rapidity of development incurs virtual unrelated items which will be difficult to remarket. It not only wastes virtual global companies' intelligence resources, but also makes it difficult for users to find suitable virtual goods fit for their virtual home in daily virtual life. In the VWs, users decorate their houses, visit others' homes, create families, host parties, and so forth. Users establish their social life circles through these activities. This research proposes a novel virtual goods recommendation method based on these social interactions. The contact strength and contact influence result from interactions with social neighbors and influence users' buying intention. Our research highlights the importance of social interactions in virtual goods recommendation. The experiment's data were retrieved from an online VW platform, and the results show that the proposed method, considering social interactions and social life circle, has better performance than existing recommendation methods.

  8. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    International Nuclear Information System (INIS)

    Karakas, Hakki Muammer; Celbis, Osman; Harma, Ahmet; Alicioglu, Banu

    2011-01-01

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 ± 14.9 years) and 43 women (41.1 ± 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 ± 12.6 mm (77-138 mm) in men and 104.7 ± 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  9. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    Energy Technology Data Exchange (ETDEWEB)

    Karakas, Hakki Muammer [Inonu University Medical Faculty, Turgut Ozal Medical Center, Department of Radiology, Malatya (Turkey); Celbis, Osman [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Forensic Medicine, Malatya (Turkey); Harma, Ahmet [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Orthopaedics and Traumatology, Malatya (Turkey); Alicioglu, Banu [Trakya University Medical Faculty, Department of Radiology, Edirne (Turkey); Trakya University Health Sciences Institute, Department of Anatomy, Edirne (Turkey)

    2011-05-15

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 {+-} 14.9 years) and 43 women (41.1 {+-} 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 {+-} 12.6 mm (77-138 mm) in men and 104.7 {+-} 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  10. Virtual computed tomography colonoscopy: artifacts, image quality and radiation dose load in a cadaver study

    International Nuclear Information System (INIS)

    Springer, P.; Stoehr, B.; Giacomuzzi, S.M.; Bodner, G.; Jaschke, W.; Nedden, D. zur; Klingler, A.

    2000-01-01

    The purpose of our study was to evaluate the interdependency of spatial resolution, image reconstruction artifacts, and radiation doses in virtual CT colonoscopy by comparing various CT scanning protocols. A pig's colon with several artificial polypoid lesions was imaged after air insufflation with helical CT scanning using 1-, 3-, and 5-mm collimation, and pitch values varying from 1.0 to 3.0. Virtual endoscopic images and ''fly through'' sequences were calculated on a Sun Sparc 20 workstation (Navigator Software, GE Medical Systems, Milwaukee, Wis.). Several reconstruction artifacts as well as overall image quality were evaluated by three independent reviewers. In addition, radiation doses for the different CT protocols were measured as multiple-scan average dose using a 10-cm ion chamber and a standard Plexiglass body phantom. Generally, image quality and reconstruction artifacts were less affected by pitch values than by beam collimation. Thus, narrow beam collimation at higher pitch values (e. g. 3 mm/2.0) seems to be a reasonable compromise between quality of virtual endoscopic images and radiation dose load. (orig.)

  11. Virtual marketing in virtual enterprises

    OpenAIRE

    Ale Ebrahim, Nader; Fattahi, Hamaid Ali; Golnam, Arash

    2008-01-01

    Virtualization caused tremendous evolution in the economics of marketing channels, patterns of physical distribution and the structure of distributors and developed a new concept that is known as virtual marketing (VM). VM combines the powerful technologies of interactive marketing and virtual reality. Virtual enterprise (VE) refers to an organization not having a clear physical locus. In other words, VE is an organization distributed geographically and whose work is coordinated through e...

  12. Simulation on a limited angle beam gamma ray tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jung, Sung Hee; Moon, Jin Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    Limited angle beam tomography was introduced in the medical field more than two decades ago, where it was mainly used for cardiovascular diagnostics. Later, it was also used to trace multiphase flows. In these studies, the detection systems were fixed and a scanning electron beam was rapidly swept across an xray target using deflection coils. Thus very fast scanning was possible in these studies, but their geometry resulted in a heavy and bulky system because of a complex control system and vacuum tube. Because of its heavy hardware, limited angle beam tomography has remained as indoor equipment. If the source section is replaced by a gamma ray source, limited angle beam tomography will have a very light source device. In addition, limited angle beam tomography with a gamma ray source can be designed using an open type portable gantry because it does not need a vacuum guide for an electron beam. There is a lot of need for a portable tomographic system but so far no definitive solution has been created. The inspection of industrial on-line pipes, wood telephone poles, and cultural assets are some application areas. This study introduces limited angle beam gamma ray tomography, its simulation, and image reconstruction results. Image reconstruction was performed on the virtual experimental data from a Monte Carlo simulation. Image reconstruction algorithms that are known to be useful for limited angle data were applied and their results compared

  13. Recent advances in 3D computed tomography techniques for simulation and navigation in hepatobiliary pancreatic surgery.

    Science.gov (United States)

    Uchida, Masafumi

    2014-04-01

    A few years ago it could take several hours to complete a 3D image using a 3D workstation. Thanks to advances in computer science, obtaining results of interest now requires only a few minutes. Many recent 3D workstations or multimedia computers are equipped with onboard 3D virtual patient modeling software, which enables patient-specific preoperative assessment and virtual planning, navigation, and tool positioning. Although medical 3D imaging can now be conducted using various modalities, including computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography (PET), and ultrasonography (US) among others, the highest quality images are obtained using CT data, and CT images are now the most commonly used source of data for 3D simulation and navigation image. If the 2D source image is bad, no amount of 3D image manipulation in software will provide a quality 3D image. In this exhibition, the recent advances in CT imaging technique and 3D visualization of the hepatobiliary and pancreatic abnormalities are featured, including scan and image reconstruction technique, contrast-enhanced techniques, new application of advanced CT scan techniques, and new virtual reality simulation and navigation imaging. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  14. Conventional versus virtual radiographs of the injured pelvis and acetabulum

    Energy Technology Data Exchange (ETDEWEB)

    Bishop, Julius A.; Rao, Allison J.; Pouliot, Michael A.; Bellino, Michael [Stanford University School of Medicine, Department of Orthopaedic Surgery, Stanford, CA (United States); Beaulieu, Christopher [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2015-09-15

    Evaluation of the fractured pelvis or acetabulum requires both standard radiographic evaluation as well as computed tomography (CT) imaging. The standard anterior-posterior (AP), Judet, and inlet and outlet views can now be simulated using data acquired during CT, decreasing patient discomfort, radiation exposure, and cost to the healthcare system. The purpose of this study is to compare the image quality of conventional radiographic views of the traumatized pelvis to virtual radiographs created from pelvic CT scans. Five patients with acetabular fractures and ten patients with pelvic ring injuries were identified using the orthopedic trauma database at our institution. These fractures were evaluated with both conventional radiographs as well as virtual radiographs generated from a CT scan. A web-based survey was created to query overall image quality and visibility of relevant anatomic structures. This survey was then administered to members of the Orthopaedic Trauma Association (OTA). Ninety-seven surgeons completed the acetabular fracture survey and 87 completed the pelvic fracture survey. Overall image quality was judged to be statistically superior for the virtual as compared to conventional images for acetabular fractures (3.15 vs. 2.98, p = 0.02), as well as pelvic ring injuries (2.21 vs. 1.45, p = 0.0001). Visibility ratings for each anatomic landmark were statistically superior with virtual images as well. Virtual radiographs of pelvic and acetabular fractures offer superior image quality, improved comfort, decreased radiation exposure, and a more cost-effective alternative to conventional radiographs. (orig.)

  15. Virtual Presenters: Towards Interactive Virtual Presentations

    NARCIS (Netherlands)

    Nijholt, Antinus; Cappellini, V.; Hemsley, J.

    2005-01-01

    We discuss having virtual presenters in virtual environments that present information to visitors of these environments. Some current research is surveyed and we will look in particular to our research in the context of a virtual meeting room where a virtual presenter uses speech, gestures, pointing

  16. Virtual Worlds for Virtual Organizing

    Science.gov (United States)

    Rhoten, Diana; Lutters, Wayne

    The members and resources of a virtual organization are dispersed across time and space, yet they function as a coherent entity through the use of technologies, networks, and alliances. As virtual organizations proliferate and become increasingly important in society, many may exploit the technical architecture s of virtual worlds, which are the confluence of computer-mediated communication, telepresence, and virtual reality originally created for gaming. A brief socio-technical history describes their early origins and the waves of progress followed by stasis that brought us to the current period of renewed enthusiasm. Examination of contemporary examples demonstrates how three genres of virtual worlds have enabled new arenas for virtual organizing: developer-defined closed worlds, user-modifiable quasi-open worlds, and user-generated open worlds. Among expected future trends are an increase in collaboration born virtually rather than imported from existing organizations, a tension between high-fidelity recreations of the physical world and hyper-stylized imaginations of fantasy worlds, and the growth of specialized worlds optimized for particular sectors, companies, or cultures.

  17. Lipoid pneumonia in adults: findings on high-resolution computed tomography

    International Nuclear Information System (INIS)

    Marchiori, Edson; Escuissato, Dante L.; Souza Junior, Arthur Soares; Araujo Neto, Cesar; Nobre, Luiz Felipe; Irion, Klaus L.; Rodrigues, Rosana; Mancano, Alexandre Dias; Capone, Domenico; Fialho, Suzane Mansur; Souza, Carolina Althoff

    2007-01-01

    Objective: The present study was aimed at describing the findings on high-resolution computed tomography in patients with exogenous lipoid pneumonia secondary to mineral oil aspiration. Materials and methods: Eight adult patients - four men and four women - with mean age of 69.4 years were studied. All of the patients were users of mineral oil for treating intestinal constipation. High-resolution computed tomography studies of these patients were blindly evaluated by two radiologists. Results: Air-space consolidation with areas of fat density and crazy paving pattern were the most frequent findings. The lesions were bilateral in six cases and unilateral in two. Conclusion: Air-space consolidation with areas of fat density, associated with a clinical history of mineral oil ingestion virtually indicates a diagnosis of exogenous lipoid pneumonia. (author)

  18. Lipoid pneumonia in adults: findings on high-resolution computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. of Radiology]. E-mail: edmarchiori@gmail.com; Zanetti, Glaucia [Faculdade de Medicina de Petropolis, RJ (Brazil); Escuissato, Dante L. [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil); Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil); Araujo Neto, Cesar [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil); Nobre, Luiz Felipe [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil); Irion, Klaus L. [The Cardiothoracic Centre NHS Trust, Liverpool (United Kingdom); Rodrigues, Rosana [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Hospital Universitario Clementino Fraga Filho (HUCFF); Mancano, Alexandre Dias [Hospital Regional de Taguatinga, Brasilia, DF (Brazil); Capone, Domenico [Universidade Estadual do Rio de Janeiro (UERJ), RJ (Brazil); Fialho, Suzane Mansur [Centro Nuclear da Guanabara, Rio de Janeiro, RJ (Brazil); Souza, Carolina Althoff [University of Ottawa (Canada)

    2007-09-15

    Objective: The present study was aimed at describing the findings on high-resolution computed tomography in patients with exogenous lipoid pneumonia secondary to mineral oil aspiration. Materials and methods: Eight adult patients - four men and four women - with mean age of 69.4 years were studied. All of the patients were users of mineral oil for treating intestinal constipation. High-resolution computed tomography studies of these patients were blindly evaluated by two radiologists. Results: Air-space consolidation with areas of fat density and crazy paving pattern were the most frequent findings. The lesions were bilateral in six cases and unilateral in two. Conclusion: Air-space consolidation with areas of fat density, associated with a clinical history of mineral oil ingestion virtually indicates a diagnosis of exogenous lipoid pneumonia. (author)

  19. Is there a superior simulator for human anatomy education? How virtual dissection can overcome the anatomic and pedagogic limitations of cadaveric dissection.

    Science.gov (United States)

    Darras, Kathryn E; de Bruin, Anique B H; Nicolaou, Savvas; Dahlström, Nils; Persson, Anders; van Merriënboer, Jeroen; Forster, Bruce B

    2018-03-23

    Educators must select the best tools to teach anatomy to future physicians and traditionally, cadavers have always been considered the "gold standard" simulator for living anatomy. However, new advances in technology and radiology have created new teaching tools, such as virtual dissection, which provide students with new learning opportunities. Virtual dissection is a novel way of studying human anatomy through patient computed tomography (CT) scans. Through touchscreen technology, students can work together in groups to "virtually dissect" the CT scans to better understand complex anatomic relationships. This article presents the anatomic and pedagogic limitations of cadaveric dissection and explains what virtual dissection is and how this new technology may be used to overcome these limitations.

  20. Feasibility of dynamic MR-hysterosalpingography for the diagnostic work-up of infertile women

    International Nuclear Information System (INIS)

    Winter, Leopold; Gluecker, Thomas; Steinbrich, Wolfgang; Pegios, Wassilios; Steimann, Sabine; De Geyter, Christian; Froehlich, Johannes M.

    2010-01-01

    Background: Tubal disturbances often contribute to infertility. Conventional hysterosalpingography (HSG) is considered as standard in the assessment of the patency of the fallopian tubes, but requires ionizing radiation and is restricted to the imaging of endoluminal structures. Purpose: To evaluate dynamic magnetic resonance-HSG (dMR-HSG) in the diagnostic work-up in patients with infertility. Material and Methods: Thirty-seven consecutive infertile women underwent dMR-HSG: 20 ml of gadolinium-polyvidone solution (18.4 mM Dotarem 1:20 with polyvidone) were injected intracervically through a 5-Charriere balloon catheter while acquiring five consecutive flash-3D T1-weighted MR sequences with fat saturation. Two experienced readers assessed image quality and anatomic-pathologic correlations prospectively. The relevance of results was evaluated in the clinical context of each patient. Patient comfort was evaluated with a standardized questionnaire. Results: dMR-HSG was successfully completed in 33/37 patient with an average study time of 45 min. In 4 of 37 patients the catheter became dislodged during the examination, resulting in two complete diagnostic failures. Failure in another two patients was due to preliminary termination because of excessive pain and discomfort during the application of the contrast solution. The uterine cavity was completely visualized and bilateral fallopian tube patency was confirmed by dMR-HSG in 27 of 33 patients. Bilateral tubal occlusion was diagnosed in one of the remaining six patients and was confirmed by laparoscopy. Successful selective tubal catheterization was performed in one additional patient with unilateral and one patient with bilateral fallopian tube occlusion. In three cases, the catheter became dislocated at the end of the examination without demonstration of tubal patency. Since all three patients refused diagnostic laparoscopy and conventional HSG, possible bilateral occlusions of the fallopian tubes could not be

  1. Feasibility of dynamic MR-hysterosalpingography for the diagnostic work-up of infertile women

    Energy Technology Data Exchange (ETDEWEB)

    Winter, Leopold; Gluecker, Thomas; Steinbrich, Wolfgang; Pegios, Wassilios (Dept. of Radiology, Univ. Hospital Basel (Switzerland)), e-mail: winterl@uhbs.ch; Steimann, Sabine; De Geyter, Christian (Women' s Hospital, Univ. Hospital Basel (Switzerland)); Froehlich, Johannes M. (Guerbet AG, Zuerich (Switzerland))

    2010-07-15

    Background: Tubal disturbances often contribute to infertility. Conventional hysterosalpingography (HSG) is considered as standard in the assessment of the patency of the fallopian tubes, but requires ionizing radiation and is restricted to the imaging of endoluminal structures. Purpose: To evaluate dynamic magnetic resonance-HSG (dMR-HSG) in the diagnostic work-up in patients with infertility. Material and Methods: Thirty-seven consecutive infertile women underwent dMR-HSG: 20 ml of gadolinium-polyvidone solution (18.4 mM Dotarem 1:20 with polyvidone) were injected intracervically through a 5-Charriere balloon catheter while acquiring five consecutive flash-3D T1-weighted MR sequences with fat saturation. Two experienced readers assessed image quality and anatomic-pathologic correlations prospectively. The relevance of results was evaluated in the clinical context of each patient. Patient comfort was evaluated with a standardized questionnaire. Results: dMR-HSG was successfully completed in 33/37 patient with an average study time of 45 min. In 4 of 37 patients the catheter became dislodged during the examination, resulting in two complete diagnostic failures. Failure in another two patients was due to preliminary termination because of excessive pain and discomfort during the application of the contrast solution. The uterine cavity was completely visualized and bilateral fallopian tube patency was confirmed by dMR-HSG in 27 of 33 patients. Bilateral tubal occlusion was diagnosed in one of the remaining six patients and was confirmed by laparoscopy. Successful selective tubal catheterization was performed in one additional patient with unilateral and one patient with bilateral fallopian tube occlusion. In three cases, the catheter became dislocated at the end of the examination without demonstration of tubal patency. Since all three patients refused diagnostic laparoscopy and conventional HSG, possible bilateral occlusions of the fallopian tubes could not be

  2. Orthotropic conductivity reconstruction with virtual-resistive network and Faraday's law

    KAUST Repository

    Lee, Min-Gi

    2015-06-01

    We obtain the existence and the uniqueness at the same time in the reconstruction of orthotropic conductivity in two-space dimensions by using two sets of internal current densities and boundary conductivity. The curl-free equation of Faraday\\'s law is taken instead of the elliptic equation in a divergence form that is typically used in electrical impedance tomography. A reconstruction method based on layered bricks-type virtual-resistive network is developed to reconstruct orthotropic conductivity with up to 40% multiplicative noise.

  3. Virtually fabricated guide for placement of the C-tube miniplate.

    Science.gov (United States)

    Paek, Janghyun; Jeong, Do-Min; Kim, Yong; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald

    2014-05-01

    This paper introduces a virtually planned and stereolithographically fabricated guiding system that will allow the clinician to plan carefully for the best location of the device and to achieve an accurate position without complications. The scanned data from preoperative dental casts were edited to obtain preoperative 3-dimensional (3D) virtual models of the dentition. After the 3D virtual models were repositioned, the 3D virtual surgical guide was fabricated. A surgical guide was created onscreen, and then these virtual guides were materialized into real ones using the stereolithographic technique. Whereas the previously described guide required laboratory work to be performed by the orthodontist, our technique is more convenient because the laboratory work is done remotely by computer-aided design/computer-aided manufacturing technology. Because the miniplate is firmly held in place as the patient holds his or her mandibular teeth against the occlusal pad of the surgical guide, there is no risk that the miniscrews can slide on the bone surface during placement. The software program (2.5-dimensional software) in this study combines 2-dimensional cephalograms with 3D virtual dental models. This software is an effective and efficient alternative to 3D software when 3D computed tomography data are not available. To confidently and safely place a miniplate with screw fixation, a simple customized guide for an orthodontic miniplate was introduced. The use of a custom-made, rigid guide when placing miniplates will minimize complications such as vertical mislocation or slippage of the miniplate during placement. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  4. A cone-beam CT based technique to augment the 3D virtual skull model with a detailed dental surface.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mommaerts, M.Y.; Abeloos, J.V.S.; Clercq, C. De; Lamoral, P.; Neyt, N.; Casselman, J.W.; Schutyser, F.A.C.

    2009-01-01

    Cone-beam computed tomography (CBCT) is used for maxillofacial imaging. 3D virtual planning of orthognathic and facial orthomorphic surgery requires detailed visualisation of the interocclusal relationship. This study aimed to introduce and evaluate the use of a double CBCT scan procedure with a

  5. Analysis of the acceptance procedure and quality control a virtual simulation system; Analisis del procedimiento de aceptacion y control de calidad de un sistema de simulacion virtual

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Ruiz, C.; Pedrero de Aristizabal, D.; Jimenez Rojas, R.; Garcia Hernandez, M. J.; Ruiz Galan, G.; Ayala Lazaro, R.; Garcia Marcos, R.

    2011-07-01

    Acceptance has been made, determining the reference state, commissioning and implementation of control protocol virtual simulation system consists of an image acquisition unit of computerized tomography (CT), an independent external location laser locator and a simulation module associated with the existing scheduler for clinical dosimetry in radiotherapy. This paper summarizes the path followed in this process, together with the established procedure for periodic monitoring and analysis system of the results obtained in the two years of clinical and control.

  6. Automatic Segmentation and Online virtualCT in Head-and-Neck Adaptive Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Peroni, Marta, E-mail: marta.peroni@mail.polimi.it [Department of Bioengineering, Politecnico di Milano, Milano (Italy); Ciardo, Delia [Advanced Radiotherapy Center, European Institute of Oncology, Milano (Italy); Spadea, Maria Francesca [Department of Experimental and Clinical Medicine, Universita degli Studi Magna Graecia, Catanzaro (Italy); Riboldi, Marco [Department of Bioengineering, Politecnico di Milano, Milano (Italy); Bioengineering Unit, Centro Nazionale di Adroterapia Oncologica, Pavia (Italy); Comi, Stefania; Alterio, Daniela [Advanced Radiotherapy Center, European Institute of Oncology, Milano (Italy); Baroni, Guido [Department of Bioengineering, Politecnico di Milano, Milano (Italy); Bioengineering Unit, Centro Nazionale di Adroterapia Oncologica, Pavia (Italy); Orecchia, Roberto [Advanced Radiotherapy Center, European Institute of Oncology, Milano (Italy); Universita degli Studi di Milano, Milano (Italy); Medical Department, Centro Nazionale di Adroterapia Oncologica, Pavia (Italy)

    2012-11-01

    Purpose: The purpose of this work was to develop and validate an efficient and automatic strategy to generate online virtual computed tomography (CT) scans for adaptive radiation therapy (ART) in head-and-neck (HN) cancer treatment. Method: We retrospectively analyzed 20 patients, treated with intensity modulated radiation therapy (IMRT), for an HN malignancy. Different anatomical structures were considered: mandible, parotid glands, and nodal gross tumor volume (nGTV). We generated 28 virtualCT scans by means of nonrigid registration of simulation computed tomography (CTsim) and cone beam CT images (CBCTs), acquired for patient setup. We validated our approach by considering the real replanning CT (CTrepl) as ground truth. We computed the Dice coefficient (DSC), center of mass (COM) distance, and root mean square error (RMSE) between correspondent points located on the automatically segmented structures on CBCT and virtualCT. Results: Residual deformation between CTrepl and CBCT was below one voxel. Median DSC was around 0.8 for mandible and parotid glands, but only 0.55 for nGTV, because of the fairly homogeneous surrounding soft tissues and of its small volume. Median COM distance and RMSE were comparable with image resolution. No significant correlation between RMSE and initial or final deformation was found. Conclusion: The analysis provides evidence that deformable image registration may contribute significantly in reducing the need of full CT-based replanning in HN radiation therapy by supporting swift and objective decision-making in clinical practice. Further work is needed to strengthen algorithm potential in nGTV localization.

  7. Automatic segmentation and online virtualCT in head-and-neck adaptive radiation therapy.

    Science.gov (United States)

    Peroni, Marta; Ciardo, Delia; Spadea, Maria Francesca; Riboldi, Marco; Comi, Stefania; Alterio, Daniela; Baroni, Guido; Orecchia, Roberto

    2012-11-01

    The purpose of this work was to develop and validate an efficient and automatic strategy to generate online virtual computed tomography (CT) scans for adaptive radiation therapy (ART) in head-and-neck (HN) cancer treatment. We retrospectively analyzed 20 patients, treated with intensity modulated radiation therapy (IMRT), for an HN malignancy. Different anatomical structures were considered: mandible, parotid glands, and nodal gross tumor volume (nGTV). We generated 28 virtualCT scans by means of nonrigid registration of simulation computed tomography (CTsim) and cone beam CT images (CBCTs), acquired for patient setup. We validated our approach by considering the real replanning CT (CTrepl) as ground truth. We computed the Dice coefficient (DSC), center of mass (COM) distance, and root mean square error (RMSE) between correspondent points located on the automatically segmented structures on CBCT and virtualCT. Residual deformation between CTrepl and CBCT was below one voxel. Median DSC was around 0.8 for mandible and parotid glands, but only 0.55 for nGTV, because of the fairly homogeneous surrounding soft tissues and of its small volume. Median COM distance and RMSE were comparable with image resolution. No significant correlation between RMSE and initial or final deformation was found. The analysis provides evidence that deformable image registration may contribute significantly in reducing the need of full CT-based replanning in HN radiation therapy by supporting swift and objective decision-making in clinical practice. Further work is needed to strengthen algorithm potential in nGTV localization. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Sensorial Virtualization: Coupling Gaming and Virtual Environment

    NARCIS (Netherlands)

    Garbaya, S.; Miraoui, C.; Wendrich, Robert E.; Lim, T.; Stanescu, I.A.; Hauge, J.B.

    2014-01-01

    Virtual reality and virtualization are currently used to design complex systems and demonstrate that they represent the functionalities of real systems. However, the design refinement of the virtual environment (VE) and distributed virtual environment (DVE) are still time consuming and costly, as it

  9. Evaluation of left ventricular function and volume with multidetector-row computed tomography. Comparison with electrocardiogram-gated single photon emission computed tomography

    International Nuclear Information System (INIS)

    Suzuki, Takeya; Yamashina, Shohei; Nanjou, Shuji; Yamazaki, Junichi

    2007-01-01

    This study compared left ventricular systolic function and volume determined by multidetector-row computed tomography (MDCT) and electrocardiogram-gated single photon emission computed tomography (G-SPECT) Thirty-seven patients with coronary artery disease and non-cardiovascular disease underwent MDCT. In this study, left ventricular ejection fraction (EF), left ventricular end-diastolic volume (EDV) and left ventricular end-systolic volume (ESV) were calculated using only two-phase imaging with MDCT. Left ventricular function and volume were compared using measurements from G-SPECT. We conducted MDCT and G-SPECT virtually simultaneously. Both the EF and ESV evaluated by MDCT closely correlated with G-SPECT (r=0.763, P 65 bpm) during MDCT significantly influenced the difference in EF calculated from MDCT and G-SPECT (P<0.05). Left ventricular function can be measured with MDCT as well as G-SPECT. However, a heart rate over 65 bpm during MDCT negatively affects the EF correlation between MDCT and G-SPECT. (author)

  10. Comparing 3-dimensional virtual methods for reconstruction in craniomaxillofacial surgery.

    Science.gov (United States)

    Benazzi, Stefano; Senck, Sascha

    2011-04-01

    In the present project, the virtual reconstruction of digital osteomized zygomatic bones was simulated using different methods. A total of 15 skulls were scanned using computed tomography, and a virtual osteotomy of the left zygomatic bone was performed. Next, virtual reconstructions of the missing part using mirror imaging (with and without best fit registration) and thin plate spline interpolation functions were compared with the original left zygomatic bone. In general, reconstructions using thin plate spline warping showed better results than the mirroring approaches. Nevertheless, when dealing with skulls characterized by a low degree of asymmetry, mirror imaging and subsequent registration can be considered a valid and easy solution for zygomatic bone reconstruction. The mirroring tool is one of the possible alternatives in reconstruction, but it might not always be the optimal solution (ie, when the hemifaces are asymmetrical). In the present pilot study, we have verified that best fit registration of the mirrored unaffected hemiface and thin plate spline warping achieved better results in terms of fitting accuracy, overcoming the evident limits of the mirroring approach. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Virtual Class Support at the Virtual Machine Level

    DEFF Research Database (Denmark)

    Nielsen, Anders Bach; Ernst, Erik

    2009-01-01

    This paper describes how virtual classes can be supported in a virtual machine.  Main-stream virtual machines such as the Java Virtual Machine and the .NET platform dominate the world today, and many languages are being executed on these virtual machines even though their embodied design choices...... conflict with the design choices of the virtual machine.  For instance, there is a non-trivial mismatch between the main-stream virtual machines mentioned above and dynamically typed languages.  One language concept that creates an even greater mismatch is virtual classes, in particular because fully...... general support for virtual classes requires generation of new classes at run-time by mixin composition.  Languages like CaesarJ and ObjectTeams can express virtual classes restricted to the subset that does not require run-time generation of classes, because of the restrictions imposed by the Java...

  12. Six-dimensional real and reciprocal space small-angle X-ray scattering tomography.

    Science.gov (United States)

    Schaff, Florian; Bech, Martin; Zaslansky, Paul; Jud, Christoph; Liebi, Marianne; Guizar-Sicairos, Manuel; Pfeiffer, Franz

    2015-11-19

    When used in combination with raster scanning, small-angle X-ray scattering (SAXS) has proven to be a valuable imaging technique of the nanoscale, for example of bone, teeth and brain matter. Although two-dimensional projection imaging has been used to characterize various materials successfully, its three-dimensional extension, SAXS computed tomography, poses substantial challenges, which have yet to be overcome. Previous work using SAXS computed tomography was unable to preserve oriented SAXS signals during reconstruction. Here we present a solution to this problem and obtain a complete SAXS computed tomography, which preserves oriented scattering information. By introducing virtual tomography axes, we take advantage of the two-dimensional SAXS information recorded on an area detector and use it to reconstruct the full three-dimensional scattering distribution in reciprocal space for each voxel of the three-dimensional object in real space. The presented method could be of interest for a combined six-dimensional real and reciprocal space characterization of mesoscopic materials with hierarchically structured features with length scales ranging from a few nanometres to a few millimetres--for example, biomaterials such as bone or teeth, or functional materials such as fuel-cell or battery components.

  13. Virtual colonoscopy with electron beam CT: correlation with barium enema, colonoscopy and pathology

    International Nuclear Information System (INIS)

    Hong, Hye Suk; Kim, Min Jung; Chung, Jae Joon; Kim, Myeong Jin; Lee, Jong Tae; Yoo, Hyung Sik

    1998-01-01

    To perform virtual colonoscopy using electron beam tomography(EBT) in patients in whom a colonic mass was present, and to compare the results with those obtained using barium enema, colonoscopy and gross pathologic specimens. Materials and Methods : Ten patients in whom colonic masses were diagnosed by either barium enema or colonoscopy were involved in this study. There were nine cases of adenocarcinoma and one of tubulovillous adenoma. Using EBT preoperative abdominopelvic CT scans were performed. Axial scans were then three-dimensionally reconstructed to produce virtual colonoscopic images and were compared with barium enema, colonoscopy and gross pathologic specimens. Virtual colonoscopic images of the masses were classified as either 1)polyploid, 2)sessile,3)fungating, or 4)annular constrictive. We also determined whether ulcers were present within the lesions and whether there was obstruction. Results : After virtual colonoscopy, two lesions were classified as polyploid, one as sessile, five as fungating and two as annular constrictive. Virtual colonoscopic images showed good correlation with the findings of barium enema, colonoscopy and gross pathologic specimens. Three of six ulcerative lesions were observed on colonoscopy; in seven adenocarcinomas with partial or total luminal obstruction, virtual colonoscopy visualized the colon beyond the obstructed sites. In one case, barium contrast failed to pass through the obstructed portion and in six cases, the colonoscope similarly failed. Conclusion : Virtual colonoscopies correlated well with barium enema, colonoscopy and gross pathologic specimens. They provide three dimensional images of colonic masses and are helpful for the evaluation of obstructive lesions

  14. Microsoft Virtualization Master Microsoft Server, Desktop, Application, and Presentation Virtualization

    CERN Document Server

    Olzak, Thomas; Boomer, Jason; Keefer, Robert M

    2010-01-01

    Microsoft Virtualization helps you understand and implement the latest virtualization strategies available with Microsoft products. This book focuses on: Server Virtualization, Desktop Virtualization, Application Virtualization, and Presentation Virtualization. Whether you are managing Hyper-V, implementing desktop virtualization, or even migrating virtual machines, this book is packed with coverage on all aspects of these processes. Written by a talented team of Microsoft MVPs, Microsoft Virtualization is the leading resource for a full installation, migration, or integration of virtual syste

  15. Periprosthetic Artifact Reduction Using Virtual Monochromatic Imaging Derived From Gemstone Dual-Energy Computed Tomography and Dedicated Software.

    Science.gov (United States)

    Reynoso, Exequiel; Capunay, Carlos; Rasumoff, Alejandro; Vallejos, Javier; Carpio, Jimena; Lago, Karen; Carrascosa, Patricia

    2016-01-01

    The aim of this study was to explore the usefulness of combined virtual monochromatic imaging and metal artifact reduction software (MARS) for the evaluation of musculoskeletal periprosthetic tissue. Measurements were performed in periprosthetic and remote regions in 80 patients using a high-definition scanner. Polychromatic images with and without MARS and virtual monochromatic images were obtained. Periprosthetic polychromatic imaging (PI) showed significant differences compared with remote areas among the 3 tissues explored (P remote tissues using monochromatic imaging with MARS (P = 0.053 bone, P = 0.32 soft tissue, and P = 0.13 fat). However, such differences were significant using PI with MARS among bone (P = 0.005) and fat (P = 0.02) tissues. All periprosthetic areas were noninterpretable using PI, compared with 11 (9%) using monochromatic imaging. The combined use of virtual monochromatic imaging and MARS reduced periprosthetic artifacts, achieving attenuation levels comparable to implant-free tissue.

  16. Virtual Library: An essential component of virtual education

    Directory of Open Access Journals (Sweden)

    M zarghani

    2015-06-01

    Full Text Available Abstract Introduction: Library is one of the essential elements of universities which provide some important educational needs of students. Virtual education can not be exempted and virtual libraries are important support for virtual training programs. The purpose of this study is to evaluate the viewpoint of administrators and students in virtual education centers about the virtual library, its role and resources. Methods: This study was a descriptive survey. The research instrument was a researcher made questionnaire that its validity and reliability was confirmed. The study population consisted of 19 virtual training centers in Tehran city. Out of 19 centers, simple randomized sampling was done in five Centers. The sample size was 360 students. Data collection was conducted online and descriptive statistics using SPSS 18 and Excel software were used. Results: The results showed that viewpoints of administrators and students about the mission and services of virtual libraries in some cases were similar and in some cases were different. One of the administrators’ reasons for setting up a virtual learning system was lifelong learning, and lack of knowledge about virtual libraries was the reason for inadequate use of virtual libraries. The best format of virtual library from the administrators’ and students’ viewpoint, was portal document format (PDF. Conclusion: One of the most important function of a virtual library, is lifelong learning and empowering users to provide information and educational needs. The main reason for not setting up a virtual library is t lack of knowledge about it.

  17. Analysis of the acceptance procedure and quality control a virtual simulation system

    International Nuclear Information System (INIS)

    Gonzalez Ruiz, C.; Pedrero de Aristizabal, D.; Jimenez Rojas, R.; Garcia Hernandez, M. J.; Ruiz Galan, G.; Ayala Lazaro, R.; Garcia Marcos, R.

    2011-01-01

    Acceptance has been made, determining the reference state, commissioning and implementation of control protocol virtual simulation system consists of an image acquisition unit of computerized tomography (CT), an independent external location laser locator and a simulation module associated with the existing scheduler for clinical dosimetry in radiotherapy. This paper summarizes the path followed in this process, together with the established procedure for periodic monitoring and analysis system of the results obtained in the two years of clinical and control.

  18. Virtual Reality and the Virtual Library.

    Science.gov (United States)

    Oppenheim, Charles

    1993-01-01

    Explains virtual reality, including proper and improper uses of the term, and suggests ways that libraries might be affected by it. Highlights include elements of virtual reality systems; possible virtual reality applications, including architecture, the chemical industry, transport planning, armed forces, and entertainment; and the virtual…

  19. From virtual environment to virtual community

    NARCIS (Netherlands)

    Nijholt, Antinus; Terano, Takao; Nishida, Toyoaki; Namatame, Akira; Tsumoto, Syusaku; Ohsawa, Yukido; Washio, Takashi

    2001-01-01

    We discuss a virtual reality theater environment and its transition to a virtual community by adding domain agents and by allowing multiple users to visit this environment. The environment has been built using VRML (Virtual Reality Modeling Language). We discuss how our ideas about this environment

  20. Advanced virtual monochromatic reconstruction of dual-energy unenhanced brain computed tomography in children: comparison of image quality against standard mono-energetic images and conventional polychromatic computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Juil [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Choi, Young Hun [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Cheon, Jung-Eun; Kim, Woo Sun; Kim, In-One [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Pak, Seong Yong [Siemens Healthineers, Seoul (Korea, Republic of); Krauss, Bernhard [Siemens Healthineers, Forchheim (Germany)

    2017-11-15

    Advanced virtual monochromatic reconstruction from dual-energy brain CT has not been evaluated in children. To determine the most effective advanced virtual monochromatic imaging energy level for maximizing pediatric brain parenchymal image quality in dual-energy unenhanced brain CT and to compare this technique with conventional monochromatic reconstruction and polychromatic scanning. Using both conventional (Mono) and advanced monochromatic reconstruction (Mono+) techniques, we retrospectively reconstructed 13 virtual monochromatic imaging energy levels from 40 keV to 100 keV in 5-keV increments from dual-source, dual-energy unenhanced brain CT scans obtained in 23 children. We analyzed gray and white matter noise ratios, signal-to-noise ratios and contrast-to-noise ratio, and posterior fossa artifact. We chose the optimal mono-energetic levels and compared them with conventional CT. For Mono+maximum optima were observed at 60 keV, and minimum posterior fossa artifact at 70 keV. For Mono, optima were at 65-70 keV, with minimum posterior fossa artifact at 75 keV. Mono+ was superior to Mono and to polychromatic CT for image-quality measures. Subjective analysis rated Mono+superior to other image sets. Optimal virtual monochromatic imaging using Mono+ algorithm demonstrated better image quality for gray-white matter differentiation and reduction of the artifact in the posterior fossa. (orig.)

  1. Usefulness of computed tomography virtual bronchoscopy in the evaluation of bronchi divisions

    International Nuclear Information System (INIS)

    Adamczyk, Michał; Tomaszewski, Grzegorz; Naumczyk, Patrycja; Kluczewska, Ewa; Walecki, Jerzy

    2013-01-01

    Since introduction of multislice CT scanners into clinical practice, virtual brochoscopy has gained a lot of quality and diagnostic potential. Nevertheless it does not have established place in diagnostics of tracheal and bronchi disorders and its potential has not been examined enough. Nowadays a majority of bronchial tree variants and lesions are revealed by bronchofiberoscopy, which is an objective and a relatively safe method, but has side effects, especially in higher-risk subjects. Therefore noninvasive techniques enabling evaluation of airways should be consistently developed and updated. Material consisted of 100 adults (45 female, 55 male) aged between 18 and 65 years (mean 40 years, median 40.5 years, SD 14.02), who underwent chest CT examination by means of a 16-slice scanner. Every patient had normal appearance of chest organs, with the exception of minor abnormalities that did not alter airways route. Divisions of bronchial tree to segmental level were evaluated and assigned to particular types by means of virtual bronchoscopy projection. In case of difficulties MPR or MinIP projection was used. The frequency of lobar bronchi divisions other than the typical ones was in: right upper lobar bronchi 45%, left 55%; middle lobar bronchi 21%, lingula 26%; right lower lobar bronchi 28%, left 29%. Subsuperior bronchus or bronchi were found on the right side in 44% and on the left side in 37%. No dependency between types of bronchial divisions on different levels was found

  2. Virtual Reality Model of the Three-Dimensional Anatomy of the Cavernous Sinus Based on a Cadaveric Image and Dissection.

    Science.gov (United States)

    Qian, Zeng-Hui; Feng, Xu; Li, Yang; Tang, Ke

    2018-01-01

    Studying the three-dimensional (3D) anatomy of the cavernous sinus is essential for treating lesions in this region with skull base surgeries. Cadaver dissection is a conventional method that has insurmountable flaws with regard to understanding spatial anatomy. The authors' research aimed to build an image model of the cavernous sinus region in a virtual reality system to precisely, individually and objectively elucidate the complete and local stereo-anatomy. Computed tomography and magnetic resonance imaging scans were performed on 5 adult cadaver heads. Latex mixed with contrast agent was injected into the arterial system and then into the venous system. Computed tomography scans were performed again following the 2 injections. Magnetic resonance imaging scans were performed again after the cranial nerves were exposed. Image data were input into a virtual reality system to establish a model of the cavernous sinus. Observation results of the image models were compared with those of the cadaver heads. Visualization of the cavernous sinus region models built using the virtual reality system was good for all the cadavers. High resolutions were achieved for the images of different tissues. The observed results were consistent with those of the cadaver head. The spatial architecture and modality of the cavernous sinus were clearly displayed in the 3D model by rotating the model and conveniently changing its transparency. A 3D virtual reality model of the cavernous sinus region is helpful for globally and objectively understanding anatomy. The observation procedure was accurate, convenient, noninvasive, and time and specimen saving.

  3. Paracetamol as a prophylactic analgesic for hysterosalpingography: A double blind randomized controlled trial

    International Nuclear Information System (INIS)

    Elson, E.M.; Ridley, N.T.F.

    2000-01-01

    AIM: To evaluate the effectiveness of paracetamol as a prophylactic analgesic for hysterosalpingography (HSG). DESIGN: A prospective double blind randomized controlled trial comparing one 1 g of paracetamol (SmithKline Beecham, Brentford, U.K.) to placebo taken 30 min before HSG. One hundred consecutive out-patients were studied prospectively. The analgesic effectiveness during the procedure and at 24 h and 1 week post procedure was analysed by a postal pain score questionnaire. Additional data on the ethnicity of the patient, sex and level of experience of the radiologist performing the hysterosalpingogram, the parity of the patient, the ease of the procedure, and whether pathology was identified were also recorded. RESULTS: Eighty-eight patients (88%) replied, 39 (44%) received paracetamol and 49 placebo (56%). During the procedure 3/39 (7%) of women in the paracetamol group were pain-free compared to 9/49 (18%) in the placebo group, which was not significant (P = 0.11). At 24 h, 15/39 (38%) of women in the paracetamol group were pain-free compared to 20/49 (41%) in the placebo group, which was not significant (P = 0.82). At 1 week, 27/39 (69%) of women in the paracetamol group were pain-free compared to 29/49 (59%) in the placebo group, which was not significant (P = 0.33). No significant difference in mean pain scores was determined during the procedure (P 0.91), or at 24 h post procedure (P = 0.94). Similarly, no difference in mean pain scores was identified with regard to the ethnicity of the patient, the sex of the radiologist performing the procedure, the level of experience of the radiologist performing the procedure, or whether pathology was present or not. Difficult cannulations were associated with higher mean pain scores, however, there was no difference in mean pain scores between the paracetamol or placebo groups for both easy and difficult cannulations. CONCLUSION: Paracetamol is not effective as a prophylactic analgesic for HSG. If a prophylactic

  4. Paracetamol as a prophylactic analgesic for hysterosalpingography: A double blind randomized controlled trial

    Energy Technology Data Exchange (ETDEWEB)

    Elson, E.M.; Ridley, N.T.F

    2000-09-01

    AIM: To evaluate the effectiveness of paracetamol as a prophylactic analgesic for hysterosalpingography (HSG). DESIGN: A prospective double blind randomized controlled trial comparing one 1 g of paracetamol (SmithKline Beecham, Brentford, U.K.) to placebo taken 30 min before HSG. One hundred consecutive out-patients were studied prospectively. The analgesic effectiveness during the procedure and at 24 h and 1 week post procedure was analysed by a postal pain score questionnaire. Additional data on the ethnicity of the patient, sex and level of experience of the radiologist performing the hysterosalpingogram, the parity of the patient, the ease of the procedure, and whether pathology was identified were also recorded. RESULTS: Eighty-eight patients (88%) replied, 39 (44%) received paracetamol and 49 placebo (56%). During the procedure 3/39 (7%) of women in the paracetamol group were pain-free compared to 9/49 (18%) in the placebo group, which was not significant (P = 0.11). At 24 h, 15/39 (38%) of women in the paracetamol group were pain-free compared to 20/49 (41%) in the placebo group, which was not significant (P = 0.82). At 1 week, 27/39 (69%) of women in the paracetamol group were pain-free compared to 29/49 (59%) in the placebo group, which was not significant (P = 0.33). No significant difference in mean pain scores was determined during the procedure (P 0.91), or at 24 h post procedure (P = 0.94). Similarly, no difference in mean pain scores was identified with regard to the ethnicity of the patient, the sex of the radiologist performing the procedure, the level of experience of the radiologist performing the procedure, or whether pathology was present or not. Difficult cannulations were associated with higher mean pain scores, however, there was no difference in mean pain scores between the paracetamol or placebo groups for both easy and difficult cannulations. CONCLUSION: Paracetamol is not effective as a prophylactic analgesic for HSG. If a prophylactic

  5. A computer-simulated liver phantom (virtual liver phantom) for multidetector computed tomography evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Funama, Yoshinori [Kumamoto University, Department of Radiological Sciences, School of Health Sciences, Kumamoto (Japan); Awai, Kazuo; Nakayama, Yoshiharu; Liu, Da; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto (Japan); Miyazaki, Osamu; Goto, Taiga [Hitachi Medical Corporation, Tokyo (Japan); Hori, Shinichi [Gate Tower Institute of Image Guided Therapy, Osaka (Japan)

    2006-04-15

    The purpose of study was to develop a computer-simulated liver phantom for hepatic CT studies. A computer-simulated liver phantom was mathematically constructed on a computer workstation. The computer-simulated phantom was calibrated using real CT images acquired by an actual four-detector CT. We added an inhomogeneous texture to the simulated liver by referring to CT images of chronically damaged human livers. The mean CT number of the simulated liver was 60 HU and we added numerous 5-to 10-mm structures with 60{+-}10 HU/mm. To mimic liver tumors we added nodules measuring 8, 10, and 12 mm in diameter with CT numbers of 60{+-}10, 60{+-}15, and 60{+-}20 HU. Five radiologists visually evaluated similarity of the texture of the computer-simulated liver phantom and a real human liver to confirm the appropriateness of the virtual liver images using a five-point scale. The total score was 44 in two radiologists, and 42, 41, and 39 in one radiologist each. They evaluated that the textures of virtual liver were comparable to those of human liver. Our computer-simulated liver phantom is a promising tool for the evaluation of the image quality and diagnostic performance of hepatic CT imaging. (orig.)

  6. Feasibility of dual-energy computed tomography in radiation therapy planning

    Science.gov (United States)

    Sheen, Heesoon; Shin, Han-Back; Cho, Sungkoo; Cho, Junsang; Han, Youngyih

    2017-12-01

    In this study, the noise level, effective atomic number ( Z eff), accuracy of the computed tomography (CT) number, and the CT number to the relative electron density EDconversion curve were estimated for virtual monochromatic energy and polychromatic energy. These values were compared to the theoretically predicted values to investigate the feasibility of the use of dual-energy CT in routine radiation therapy planning. The accuracies of the parameters were within the range of acceptability. These results can serve as a stepping stone toward the routine use of dual-energy CT in radiotherapy planning.

  7. Virtual Team Governance: Addressing the Governance Mechanisms and Virtual Team Performance

    Science.gov (United States)

    Zhan, Yihong; Bai, Yu; Liu, Ziheng

    As technology has improved and collaborative software has been developed, virtual teams with geographically dispersed members spread across diverse physical locations have become increasingly prominent. Virtual team is supported by advancing communication technologies, which makes virtual teams able to largely transcend time and space. Virtual teams have changed the corporate landscape, which are more complex and dynamic than traditional teams since the members of virtual teams are spread on diverse geographical locations and their roles in the virtual team are different. Therefore, how to realize good governance of virtual team and arrive at good virtual team performance is becoming critical and challenging. Good virtual team governance is essential for a high-performance virtual team. This paper explores the performance and the governance mechanism of virtual team. It establishes a model to explain the relationship between the performance and the governance mechanisms in virtual teams. This paper is focusing on managing virtual teams. It aims to find the strategies to help business organizations to improve the performance of their virtual teams and arrive at the objectives of good virtual team management.

  8. Image-based path planning for automated virtual colonoscopy navigation

    Science.gov (United States)

    Hong, Wei

    2008-03-01

    Virtual colonoscopy (VC) is a noninvasive method for colonic polyp screening, by reconstructing three-dimensional models of the colon using computerized tomography (CT). In virtual colonoscopy fly-through navigation, it is crucial to generate an optimal camera path for efficient clinical examination. In conventional methods, the centerline of the colon lumen is usually used as the camera path. In order to extract colon centerline, some time consuming pre-processing algorithms must be performed before the fly-through navigation, such as colon segmentation, distance transformation, or topological thinning. In this paper, we present an efficient image-based path planning algorithm for automated virtual colonoscopy fly-through navigation without the requirement of any pre-processing. Our algorithm only needs the physician to provide a seed point as the starting camera position using 2D axial CT images. A wide angle fisheye camera model is used to generate a depth image from the current camera position. Two types of navigational landmarks, safe regions and target regions are extracted from the depth images. Camera position and its corresponding view direction are then determined using these landmarks. The experimental results show that the generated paths are accurate and increase the user comfort during the fly-through navigation. Moreover, because of the efficiency of our path planning algorithm and rendering algorithm, our VC fly-through navigation system can still guarantee 30 FPS.

  9. Preoperative Planning Using 3D Reconstructions and Virtual Endoscopy for Location of the Frontal Sinus

    Directory of Open Access Journals (Sweden)

    Abreu, João Paulo Saraiva

    2011-01-01

    Full Text Available Introduction: Computed tomography (TC generated tridimensional (3D reconstructions allow the observation of cavities and anatomic structures of our body with detail. In our specialty there have been attempts to carry out virtual endoscopies and laryngoscopies. However, such application has been practically abandoned due to its complexity and need for computers with high power of graphic processing. Objective: To demonstrate the production of 3D reconstructions from CTs of patients in personal computers, with a free specific program and compare them to the surgery actual endoscopic images. Method: Prospective study in which the CTs proper files of 10 patients were reconstructed with the program Intage Realia, version 2009, 0, 0, 702 (KGT Inc., Japan. The reconstructions were carried out before the surgeries and a virtual endoscopy was made to assess the recess and frontal sinus region. After this study, the surgery was digitally performed and stored. The actual endoscopic images of the recess and frontal sinus region were compared to the virtual images. Results: The 3D reconstruction and virtual endoscopy were made in 10 patients submitted to the surgery. The virtual images had a large resemblance with the actual surgical images. Conclusion: With relatively simple tools and personal computer, we demonstrated the possibility to generate 3D reconstructions and virtual endoscopies. The preoperative knowledge of the frontal sinus natural draining path location may generate benefits during the performance of surgeries. However, more studies must be developed for the evaluation of the real roles of such 3D reconstructions and virtual endoscopies.

  10. Computed tomography of a medium size Roman bronze statue of Cupid

    Science.gov (United States)

    Bettuzzi, M.; Casali, F.; Morigi, M. P.; Brancaccio, R.; Carson, D.; Chiari, G.; Maish, J.

    2015-03-01

    Diagnostics based on X-ray computed tomography (CT) are becoming increasingly important, not only in the medical field but in industry and cultural heritage. CT devices typical for medical applications, however, can seldom be used on art objects because both they are not easily transportable and they often present high X-ray absorption. It is therefore necessary to make use of portable instrumentation and/or to develop tomographic systems optimized to the characteristics of the objects under examination. This work describes the computed tomography of a first century A.D. Roman bronze statue of Cupid (96.AB.53) in the collection of the J. Paul Getty Museum, within the collaborative framework between the Getty Conservation Institute and the Department of Physics and Astronomy (DIFA) of the University of Bologna (Italy). The tomography performed at the Getty facilities employed a 450 kV X-ray tube and a detection system developed at DIFA. The study highlighted the casting and construction techniques used by Roman foundry workers and provided information on the status of conservation of the statue. A 3D virtual reconstruction allowed the user to define different cross-sections enabling the study of the internal features.

  11. X-Ray longitudinal and computed tomography in the diagnosis of peripheral tumor-like formations of the lungs

    International Nuclear Information System (INIS)

    Sokolov, V.A.; Kartashov, V.M.; Piven', A.I.; Krasnoborova, S.Yu.; Blinova, L.V.; Savel'ev, A.V.

    1997-01-01

    Fifty eight patients with peripheral tumor-like formations of the lung (33 with cancer and 25 with benign formations) were examined by longitudinal tomography and CT. The potentialities f the two techniques in detecting the major semiotic signs of cancer and malignant formations were compared. The main or major signs, such as the shape of shadow and the pattern of outlines, which make it possible to differentiate bening and malignant formations, are virtually equally imaged by the two techniques. CT is superior to X-ray longitudinal tomography in revealing minor calcifications and microdestructions, hyperplastic intrathoracic lymph nodes. The significance of some symptoms for differential diagnosis calls for further clarification

  12. Innovative application of virtual display technique in virtual museum

    Science.gov (United States)

    Zhang, Jiankang

    2017-09-01

    Virtual museum refers to display and simulate the functions of real museum on the Internet in the form of 3 Dimensions virtual reality by applying interactive programs. Based on Virtual Reality Modeling Language, virtual museum building and its effective interaction with the offline museum lie in making full use of 3 Dimensions panorama technique, virtual reality technique and augmented reality technique, and innovatively taking advantages of dynamic environment modeling technique, real-time 3 Dimensions graphics generating technique, system integration technique and other key virtual reality techniques to make sure the overall design of virtual museum.3 Dimensions panorama technique, also known as panoramic photography or virtual reality, is a technique based on static images of the reality. Virtual reality technique is a kind of computer simulation system which can create and experience the interactive 3 Dimensions dynamic visual world. Augmented reality, also known as mixed reality, is a technique which simulates and mixes the information (visual, sound, taste, touch, etc.) that is difficult for human to experience in reality. These technologies make virtual museum come true. It will not only bring better experience and convenience to the public, but also be conducive to improve the influence and cultural functions of the real museum.

  13. Realistic Visualization of Virtual Views and Virtual Cinema

    DEFF Research Database (Denmark)

    Livatino, Salvatore

    2005-01-01

    Realistic Virtual View Visualization is a new field of research which has received increasing attention in recent years. It is strictly related to the increased popularity of virtual reality and the spread of its applications, among which virtual photography and cinematography. The use of computer...... generated characters, "virtual actors", in the motion picture production increases every day. While the most known computer graphics techniques have largely been adopted successfully in nowadays fictions, it still remains very challenging to implement virtual actors which would resemble, visually, human...... beings. Interestingly, film directors have been looking at the recent progress achieved by the research community in the field of realistic visualization of virtual views, and they have successfully implemented state of the art research approaches in their productions. An innovative concept...

  14. Prospective study of device-related complications in intensive care unit detected by virtual autopsy.

    Science.gov (United States)

    Wichmann, D; Heinemann, A; Zähler, S; Vogel, H; Höpker, W; Püschel, K; Kluge, S

    2018-06-01

    There has been increasing use of invasive techniques, such as extracorporeal organ support, in intensive care units (ICU), and declining autopsy rates. Thus, new measures are needed to maintain high-quality standards. We investigated the potential of computed tomography (CT)-based virtual autopsy to substitute for medical autopsy in this setting. We investigated the potential of virtual autopsy by post-mortem CT to identify complications associated with medical devices in a prospective study of patients who had died in the ICU. Clinical records were reviewed to determine the number and types of medical devices used, and findings from medical and virtual autopsies, related and unrelated to the medical devices, were compared. Medical and virtual autopsies could be performed in 61 patients (Group M/V), and virtual autopsy only in 101 patients (Group V). In Group M/V, 41 device-related complications and 30 device malpositions were identified, but only with a low inter-method agreement. Major findings unrelated to a device were identified in about 25% of patients with a high level of agreement between methods. In Group V, 8 device complications and 36 device malpositions were identified. Device-related complications are frequent in ICU patients. Virtual and medical autopsies showed clear differences in the detection of complications and device malpositions. Both methods should supplement each other rather than one alone for quality control of medical devices in the ICU. Further studies should focus on the identification of special patient populations in which virtual autopsy might be of particular benefit. NCT01541982. Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  15. Virtual Trondheim: A Virtual Environment for Tourism and Education

    OpenAIRE

    Jose, Dawn Alphonse

    2015-01-01

    The purpose of this study is to investigate whether educational activities in tourism can be supported by virtual reality technologies, using virtual world frameworks. Settings of virtual world of SecondLife and a recent Virtual Reality technology known as Oculus Rift were used in the thesis work with the city of Trondheim as the main context. Theoretical studies on Virtual Reality systems were conducted and data for the research were obtained through empirical studies condu...

  16. Virtual Trackballs Revisited

    DEFF Research Database (Denmark)

    Henriksen, Knud; Sporring, Jon; Hornbæk, Kasper

    2004-01-01

    reviews and provides a mathematical foundation for virtual trackballs. The first, but still popular, virtual trackball was described by Chen et al. [CHECK END OF SENTENCE]. We show that the virtual trackball by Chen et al. does not rotate the object along the intended great circular arc on the virtual...... trackball and we give a correction. Another popular virtual trackball is Shoemake's quaternion implementation [CHECK END OF SENTENCE], which we show to be a special case of the virtual trackball by Chen et al.. Shoemake extends the scope of the virtual trackball to the full screen. Unfortunately, Shoemake......'s virtual trackball is inhomogeneous and discontinuous with consequences for usability. Finally, we review Bell's virtual trackball [CHECK END OF SENTENCE] and discuss studies of the usability of virtual trackballs....

  17. Personal Virtual Libraries

    Science.gov (United States)

    Pappas, Marjorie L.

    2004-01-01

    Virtual libraries are becoming more and more common. Most states have a virtual library. A growing number of public libraries have a virtual presence on the Web. Virtual libraries are a growing addition to school library media collections. The next logical step would be personal virtual libraries. A personal virtual library (PVL) is a collection…

  18. Hysterosalpingographic Appearances of Female Genital Tract Tuberculosis: Part I. Fallopian Tube

    Directory of Open Access Journals (Sweden)

    Firoozeh Ahmadi

    2014-01-01

    Full Text Available Female genital tuberculosis (TB remains as a major cause of tubal obstruction leading to infertility, especially in developing countries. The global prevalence of genital tuberculosis has increased during the past two decades due to increasing acquired immunodeficiency syndrome (AIDS. Genital TB is commonly asymptomatic, and it is diagnosed during infertility investigations. Despite of recent advances in imaging tools, such as computerized tomography (CT scan, magnetic resonance imaging (MRI and ultrasongraphy, hysterosalpingography is still the standard screening test for evaluation of tubal infertility and a valuable tool for diagnosis of female genital tuberculosis. Tuberculosis gives rise to various appearances on hysterosalpingography (HSG from non-specific changes to specific findings. The present pictorial review illustrates and describes specific and non-specific radiographic features of female genital tuberculosis in two parts. Part I presents specific findings of tuberculosis related to tubes such as "beaded tube", "golf club tube", "pipestem tube", "cobble stone tube" and "leopard skin tube". Part II describes adverse effects of tuberculosis on structure of endometrium and radiological specific findings such as "dwarfed" uterus with lymphatic intravasation and occluded tubes, "T-shaped" tuberculosis uterus, "pseudounicornuate" uterus and "Collar-stud abscess", which have not been encountered in the majority of non-tuberculosis cases.

  19. Wireless virtualization

    CERN Document Server

    Wen, Heming; Le-Ngoc, Tho

    2013-01-01

    This SpringerBriefs is an overview of the emerging field of wireless access and mobile network virtualization. It provides a clear and relevant picture of the current virtualization trends in wireless technologies by summarizing and comparing different architectures, techniques and technologies applicable to a future virtualized wireless network infrastructure. The readers are exposed to a short walkthrough of the future Internet initiative and network virtualization technologies in order to understand the potential role of wireless virtualization in the broader context of next-generation ubiq

  20. Virtual colonoscopy

    Science.gov (United States)

    Colonoscopy - virtual; CT colonography; Computed tomographic colonography; Colography - virtual ... Differences between virtual and conventional colonoscopy include: VC can view the colon from many different angles. This is not as easy ...

  1. Virtual Exploratories

    DEFF Research Database (Denmark)

    Jensen, Sisse Siggaard

    2006-01-01

    -systems, the paper introduces the designing strategy referred to as virtual exploratories. Some of the advanced virtual worlds may inspire the design of such provoking and challenging virtual exploratories, and especially the Massively Multi-User Online Role-Playing Games (MMORPGS). However, if we have to learn from...... the design and activity of the advanced virtual worlds and role-playing games, then the empirical research on the actors’ activity, while they are acting, is an important precondition to it. A step towards the conception of such a designing strategy for virtual exploratories is currently pursued....... [1] The research project: Actors and Avatars Communicating in Virtual Worlds – an Empirical Analysis of Actors’ Sense-making Strategies When Based on a Communication Theoretical Approach’ (2006-2007) is supported...

  2. The geometrical precision of virtual bone models derived from clinical computed tomography data for forensic anthropology

    NARCIS (Netherlands)

    Colman, Kerri L.; Dobbe, Johannes G. G.; Stull, Kyra E.; Ruijter, Jan M.; Oostra, Roelof-Jan; van Rijn, Rick R.; van der Merwe, Alie E.; de Boer, Hans H.; Streekstra, Geert J.

    2017-01-01

    Almost all European countries lack contemporary skeletal collections for the development and validation of forensic anthropological methods. Furthermore, legal, ethical and practical considerations hinder the development of skeletal collections. A virtual skeletal database derived from clinical

  3. Thoracoscopic surgery for pulmonary metastases after chemotherapy using a tailor-made virtual lung

    International Nuclear Information System (INIS)

    Akiba, Tadashi; Marushima, Hideki; Kinoshita, Satoki; Kamiya, Noriteru; Odaka, Makoto; Takeyama, Hiroshi; Morikawa, Toshiaki

    2011-01-01

    Details with regard to the standard criteria for a therapeutic metastasectomy and the use of video-assisted thoracic surgery (VATS) remain elusive. To evaluate the feasibility of VATS using a tailor-made virtual lung for patients with pulmonary metastases after chemotherapy, we reviewed the following cases. Clinical data from October 2006 to April 2010 were obtained from patients who received chemotherapy before a pulmonary metastasectomy (lobectomy or segmentectomy). VATS was the primarily selected surgical approach except for treating hilar lesions. A lobectomy was performed when the metastasis was greater than 3.0 cm in diameter or located deeply in the lobe. Tailor-made virtual lungs were created using three-dimensional multidetector computed tomography before lobectomy on a routine basis. The virtual lung consisted of three-dimensional pulmonary vessels, a tracheobronchial tree, pulmonary parenchyma, and tumors. Twelve operations, consisting of 1 segmentectomy, 10 lobectomies, and 1 wedge bronchoplasty upper lobectomy, were performed on 11 patients during the study period. VATS was completed in 10 of these 12 operations. The mean operative time for the lobectomies was 257 min, and the mean operative bleeding volume was 215 ml. Two cases experienced postoperative transient atrial fibrillation, and no mortalities associated with these operations were reported. VATS was performed safely in instances of metastasectomy after chemotherapy, and the tailor-made virtual lung assisted in lung orientation during the operation. (author)

  4. Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomography.

    Science.gov (United States)

    Kim, Seong-Hun; Choi, Yong-Suk; Hwang, Eui-Hwan; Chung, Kyu-Rhim; Kook, Yoon-Ah; Nelson, Gerald

    2007-04-01

    This article illustrates a new surgical guide system that uses cone-beam computed tomography (CBCT) images to replicate dental models; surgical guides for the proper positioning of orthodontic mini-implants were fabricated on the replicas, and the guides were used for precise placement. The indications, efficacy, and possible complications of this method are discussed. Patients who were planning to have orthodontic mini-implant treatment were recruited for this study. A CBCT system (PSR 9000N, Asahi Roentgen, Kyoto, Japan) was used to acquire virtual slices of the posterior maxilla that were 0.1 to 0.15 mm thick. Color 3-dimensional rapid prototyping was used to differentiate teeth, alveolus, and maxillary sinus wall. A surgical guide for the mini-implant was fabricated on the replica model. Proper positioning for mini-implants on the posterior maxilla was determined by viewing the CBCT images. The surgical guide was placed on the clinical site, and it allowed precise pilot drilling and accurate placement of the mini-implant. CBCT imaging allows remarkably lower radiation doses and thinner acquisition slices compared with medical computed tomography. Virtually reproduced replica models enable precise planning for mini-implant positions in anatomically complex sites.

  5. Sensitivity-based virtual fields for the non-linear virtual fields method

    Science.gov (United States)

    Marek, Aleksander; Davis, Frances M.; Pierron, Fabrice

    2017-09-01

    The virtual fields method is an approach to inversely identify material parameters using full-field deformation data. In this manuscript, a new set of automatically-defined virtual fields for non-linear constitutive models has been proposed. These new sensitivity-based virtual fields reduce the influence of noise on the parameter identification. The sensitivity-based virtual fields were applied to a numerical example involving small strain plasticity; however, the general formulation derived for these virtual fields is applicable to any non-linear constitutive model. To quantify the improvement offered by these new virtual fields, they were compared with stiffness-based and manually defined virtual fields. The proposed sensitivity-based virtual fields were consistently able to identify plastic model parameters and outperform the stiffness-based and manually defined virtual fields when the data was corrupted by noise.

  6. On virtual displacement and virtual work in Lagrangian dynamics

    International Nuclear Information System (INIS)

    Ray, Subhankar; Shamanna, J

    2006-01-01

    The confusion and ambiguity encountered by students in understanding virtual displacement and virtual work is discussed in this paper. A definition of virtual displacement is presented that allows one to express them explicitly for holonomic (velocity independent), non-holonomic (velocity dependent), scleronomous (time independent) and rheonomous (time dependent) constraints. It is observed that for holonomic, scleronomous constraints, the virtual displacements are the displacements allowed by the constraints. However, this is not so for a general class of constraints. For simple physical systems, it is shown that the work done by the constraint forces on virtual displacements is zero. This motivates Lagrange's extension of d'Alembert's principle to a system of particles in constrained motion. However, a similar zero work principle does not hold for the allowed displacements. It is also demonstrated that d'Alembert's principle of zero virtual work is necessary for the solvability of a constrained mechanical problem. We identify this special class of constraints, physically realized and solvable, as the ideal constraints. The concept of virtual displacement and the principle of zero virtual work by constraint forces are central to both Lagrange's method of undetermined multipliers and Lagrange's equations in generalized coordinates

  7. Virtual Reality

    Science.gov (United States)

    1993-04-01

    until exhausted. SECURITY CLASSIFICATION OF THIS PAGE All other editions are obsolete. UNCLASSIFIED " VIRTUAL REALITY JAMES F. DAILEY, LIEUTENANT COLONEL...US" This paper reviews the exciting field of virtual reality . The author describes the basic concepts of virtual reality and finds that its numerous...potential benefits to society could revolutionize everyday life. The various components that make up a virtual reality system are described in detail

  8. Framework for Virtual Cognitive Experiment in Virtual Geographic Environments

    Directory of Open Access Journals (Sweden)

    Fan Zhang

    2018-01-01

    Full Text Available Virtual Geographic Environment Cognition is the attempt to understand the human cognition of surface features, geographic processes, and human behaviour, as well as their relationships in the real world. From the perspective of human cognition behaviour analysis and simulation, previous work in Virtual Geographic Environments (VGEs has focused mostly on representing and simulating the real world to create an ‘interpretive’ virtual world and improve an individual’s active cognition. In terms of reactive cognition, building a user ‘evaluative’ environment in a complex virtual experiment is a necessary yet challenging task. This paper discusses the outlook of VGEs and proposes a framework for virtual cognitive experiments. The framework not only employs immersive virtual environment technology to create a realistic virtual world but also involves a responsive mechanism to record the user’s cognitive activities during the experiment. Based on the framework, this paper presents two potential implementation methods: first, training a deep learning model with several hundred thousand street view images scored by online volunteers, with further analysis of which visual factors produce a sense of safety for the individual, and second, creating an immersive virtual environment and Electroencephalogram (EEG-based experimental paradigm to both record and analyse the brain activity of a user and explore what type of virtual environment is more suitable and comfortable. Finally, we present some preliminary findings based on the first method.

  9. Virtualization Security Combining Mandatory Access Control and Virtual Machine Introspection

    OpenAIRE

    Win, Thu Yein; Tianfield, Huaglory; Mair, Quentin

    2014-01-01

    Virtualization has become a target for attacks in cloud computing environments. Existing approaches to protecting the virtualization environment against the attacks are limited in protection scope and are with high overheads. This paper proposes a novel virtualization security solution which aims to provide comprehensive protection of the virtualization environment.

  10. Virtual resistive network and conductivity reconstruction with Faraday's law

    International Nuclear Information System (INIS)

    Lee, Min Gi; Ko, Min-Su; Kim, Yong-Jung

    2014-01-01

    A network-based conductivity reconstruction method is introduced using the third Maxwell equation, or Faraday's law, for a static case. The usual choice in electrical impedance tomography is the divergence-free equation for the electrical current density. However, if the electrical current density is given, the curl-free equation for the electrical field gives a direct relation between the current and the conductivity and this relation is used in this paper. Mimetic discretization is applied to the equation, which gives the virtual resistive network system. Properties of the numerical schemes introduced are investigated and their advantages over other conductivity reconstruction methods are discussed. Numerically simulated results, with an analysis of noise propagation, are presented. (paper)

  11. Virtual Box

    DEFF Research Database (Denmark)

    Davis, Hilary; Skov, Mikael B.; Stougaard, Malthe

    2007-01-01

    . This paper reports on the design, implementation and initial evaluation of Virtual Box. Virtual Box attempts to create a physical and engaging context in order to support reciprocal interactions with expressive content. An implemented version of Virtual Box is evaluated in a location-aware environment...

  12. Realidad virtual y materialidad

    OpenAIRE

    Pérez Herranz, Fernando Miguel

    2009-01-01

    1. Fenomenología de partida: Real / Simbólico / Imaginario 2. Realidad 3. Virtual 3.1. Virtual / real / posible / probable 3.2. Los contextos de la realidad virtual A) REALIDAD VIRTUAL INMERSIVA B) REALIDAD VIRTUAL NO INMERSIVA C) REALIDAD VIRTUAL Y DIGITALIZACIÓN 3.3. Cruce virtual / real 3.4. Cuestiones filosóficas 4. Materialidad 5. Materialidad y descentramiento 5.1. Ejemplos de descentramiento en los contextos de Realidad Virtual A’) DUALISMO CARTESIANO, CUERPO Y «CIBORG » B’) EL ESPÍRIT...

  13. A virtual network computer's optical storage virtualization scheme

    Science.gov (United States)

    Wang, Jianzong; Hu, Huaixiang; Wan, Jiguang; Wang, Peng

    2008-12-01

    In this paper, we present the architecture and implementation of a virtual network computers' (VNC) optical storage virtualization scheme called VOSV. Its task is to manage the mapping of virtual optical storage to physical optical storage, a technique known as optical storage virtualization. The design of VOSV aims at the optical storage resources of different clients and servers that have high read-sharing patterns. VOSV uses several schemes such as a two-level Cache mechanism, a VNC server embedded module and the iSCSI protocols to improve the performance. The results measured on the prototype are encouraging, and indicating that VOSV provides the high I/O performance.

  14. Virtual bronchoscopy

    International Nuclear Information System (INIS)

    Rogalla, P.; Meiri, N.; Hamm, B.; Rueckert, J.C.; Schmidt, B.; Witt, C.

    2001-01-01

    Flexible bronchoscopy represents a clinically well-established invasive diagnostic tool. Virtual bronchoscopies, calculated from thin-slice CT sections, allow astonishing immitations of reality although principal differences exist between both technologies: the Fact that colour representation is artificial and concommitant interventions are impossible limits the clinical use of virtual bronchoscopy. However, its value increases when calculations can be attained within minutes due to technological advancements, and when virtually any chest CT is suitable for further postprocessing. Indications, findings and the clinical role of virtual bronchoscopy are discussed. (orig.) [de

  15. Virtual button interface

    Science.gov (United States)

    Jones, J.S.

    1999-01-12

    An apparatus and method of issuing commands to a computer by a user interfacing with a virtual reality environment are disclosed. To issue a command, the user directs gaze at a virtual button within the virtual reality environment, causing a perceptible change in the virtual button, which then sends a command corresponding to the virtual button to the computer, optionally after a confirming action is performed by the user, such as depressing a thumb switch. 4 figs.

  16. Colon dissection: a new three-dimensional reconstruction tool for computed tomography colonography

    International Nuclear Information System (INIS)

    Roettgen, R.; Fischbach, F.; Plotkin, M.; Herzog, H.; Freund, T.; Schroeder, R. J.; Felix, R.

    2005-01-01

    Purpose: To improve the sensitivity of computed tomography (CT) colonography in the detection of polyps by comparing the 3D reconstruction tool 'colon dissection' and endoluminal view (virtual colonoscopy) with axial 2D reconstructions. Material and Methods: Forty-eight patients (22 M, 26 F, mean age 57±21) were studied after intra-anal air insufflation in the supine and prone positions using a 16-slice helical CT (16x0.625 mm, pitch 1.7; detector rotation time 0.5 s; 160 mAs und 120 kV) and conventional colonoscopy. Two radiologists blinded to the results of the conventional colonoscopy analyzed the 3D reconstruction in virtual-endoscopy mode, in colon-dissection mode, and axial 2D slices. Results: Conventional colonoscopy revealed a total of 35 polyps in 15 patients; 33 polyps were disclosed by CT methods. Sensitivity and specificity for detecting colon polyps were 94% and 94%, respectively, when using the 'colon dissection', 89% and 94% when using 'virtual endoscopy', and 62% and 100% when using axial 2D reconstruction. Sensitivity in relation to the diameter of colon polyps with 'colon dissection', 'virtual colonoscopy', and axial 2D-slices was: polyps with a diameter >5.0 mm, 100%, 100%, and 71%, respectively; polyps with a diameter of between 3 and 4.9 mm, 92%, 85%, and 46%; and polyps with a diameter <3 mm, 89%, 78%, and 56%. The difference between 'virtual endoscopy' and 'colon dissection' in diagnosing polyps up to 4.9 mm in diameter was statistically significant. Conclusion: 3D reconstruction software 'colon dissection' improves sensitivity of CT colonography compared with the endoluminal view

  17. Accuracy and reproducibility of virtual edentulous casts created by laboratory impression scan protocols.

    Science.gov (United States)

    Peng, Lingyan; Chen, Li; Harris, Bryan T; Bhandari, Bikash; Morton, Dean; Lin, Wei-Shao

    2018-04-24

    Although computer-aided design and computer-aided manufacturing (CAD-CAM) complete removable dental prostheses (CRDPs) have gained popularity, conventional impressions are still common for CAD-CAM CRDP treatment. These need to be digitized and converted into virtual edentulous casts with a laboratory impression scan protocol during prosthesis fabrication. How this can best be accomplished is unclear. The purpose of this in vitro study was to compare the accuracy and reproducibility of virtual edentulous casts created by a dental laboratory laser scanner and a cone-beam computed tomography (CBCT) scanner with a digitized master cast. A master cast was digitized as the virtual reference cast. Ten polyvinyl siloxane impressions were made on the master cast and scanned with the dental laboratory laser scanner and CBCT scanner. The impressions were sprayed with antiglare spray and rescanned. Four groups of virtual study casts (N=40) were created from the impression scans. All virtual study casts and the reference cast were registered with surface-matching software, and the root mean square (RMS) values (representation of overall accuracy) and percentage of measurement data points within 1 standard deviation (SD) of mean RMS values (%, representation of overall reproducibility) among the 4 study groups were measured. Additionally, 95 numeric distance differences (representation of accuracy at each region) were measured in 5 distinct regions: the apex of the denture border, 6 mm from denture border, crest of the ridge, palate, and posterior palatal seal. The repeated-measures ANOVA and post hoc test (t grouping) were used to determine statistical differences (α=.05). The laboratory scanner group had a significantly larger RMS value (4.0 ±0.3 μm, Pvirtual edentulous casts, and the antiglare spray only significantly improved the accuracy and reproducibility of virtual edentulous casts created by the dental laboratory laser scanner. The accuracy of the virtual edentulous

  18. Virtual Web Services

    OpenAIRE

    Rykowski, Jarogniew

    2007-01-01

    In this paper we propose an application of software agents to provide Virtual Web Services. A Virtual Web Service is a linked collection of several real and/or virtual Web Services, and public and private agents, accessed by the user in the same way as a single real Web Service. A Virtual Web Service allows unrestricted comparison, information merging, pipelining, etc., of data coming from different sources and in different forms. Detailed architecture and functionality of a single Virtual We...

  19. Algorithmic fundamentals of computerized tomography and of transverse analogue tomography

    International Nuclear Information System (INIS)

    Heckmann, K.

    1981-01-01

    Computerized tomography and transverse analogue tomography are two different approaches to the same goal, namely, transverse tomography. The algorithm is discussed and compared. Transverse tomography appears capable of further development, judging by this comparison. (orig.) [de

  20. Structure functions of longitudinal virtual photons at low virtualities

    International Nuclear Information System (INIS)

    Ioffe, B.L.; Shushpanov, I.A.

    1996-01-01

    The structure functions F L 1 and F L 2 of longitudinal virtual photons at low virtualities are calculated in the framework of chiral perturbation theory (ChPT) in the zero and first order of ChPT. It is assumed that the virtuality of a target longitudinal photon p 2 is much less than the virtuality of the hard projectile photon Q 2 and both are less than the characteristic ChPT scale. In this approximation the structure functions are determined by the production of two pions in γγ collisions. The numerical results for F L 2 and F L 1 are presented (the upper index refers to the longitudinal polarization of the virtual target photon). The possibilities of measurements of these structure functions are briefly discussed. copyright 1996 The American Physical Society

  1. Virtual hand: a 3D tactile interface to virtual environments

    Science.gov (United States)

    Rogowitz, Bernice E.; Borrel, Paul

    2008-02-01

    We introduce a novel system that allows users to experience the sensation of touch in a computer graphics environment. In this system, the user places his/her hand on an array of pins, which is moved about space on a 6 degree-of-freedom robot arm. The surface of the pins defines a surface in the virtual world. This "virtual hand" can move about the virtual world. When the virtual hand encounters an object in the virtual world, the heights of the pins are adjusted so that they represent the object's shape, surface, and texture. A control system integrates pin and robot arm motions to transmit information about objects in the computer graphics world to the user. It also allows the user to edit, change and move the virtual objects, shapes and textures. This system provides a general framework for touching, manipulating, and modifying objects in a 3-D computer graphics environment, which may be useful in a wide range of applications, including computer games, computer aided design systems, and immersive virtual worlds.

  2. Virtual Monoenergetic Images From a Novel Dual-Layer Spectral Detector Computed Tomography Scanner in Portal Venous Phase: Adjusted Window Settings Depending on Assessment Focus Are Essential for Image Interpretation.

    Science.gov (United States)

    Hickethier, Tilman; Iuga, Andra-Iza; Lennartz, Simon; Hauger, Myriam; Byrtus, Jonathan; Luetkens, Julian A; Haneder, Stefan; Maintz, David; Doerner, Jonas

    We aimed to determine optimal window settings for conventional polyenergetic (PolyE) and virtual monoenergetic images (MonoE) derived from abdominal portal venous phase computed tomography (CT) examinations on a novel dual-layer spectral-detector CT (SDCT). From 50 patients, SDCT data sets MonoE at 40 kiloelectron volt as well as PolyE were reconstructed and best individual window width and level values manually were assessed separately for evaluation of abdominal arteries as well as for liver lesions. Via regression analysis, optimized individual values were mathematically calculated. Subjective image quality parameters, vessel, and liver lesion diameters were measured to determine influences of different W/L settings. Attenuation and contrast-to-noise values were significantly higher in MonoE compared with PolyE. Compared with standard settings, almost all adjusted W/L settings varied significantly and yielded higher subjective scoring. No differences were found between manually adjusted and mathematically calculated W/L settings. PolyE and MonoE from abdominal portal venous phase SDCT examinations require appropriate W/L settings depending on reconstruction technique and assessment focus.

  3. Dual-energy CT in the evaluation of solitary pulmonary nodules by virtual non-enhanced images: initial experience

    International Nuclear Information System (INIS)

    Guo Xing; Ding Wei; Qin Huijuan

    2011-01-01

    Objective: To determine the accuracy and radiation dose of dual-energy computed tomography (CT) in evaluating solitary pulmonary nodules (SPNs) by virtual non-enhanced images. Methods: Sixty-one patients with SPNs including 39 malignant and 18 benign nodules proved by pathology underwent DECT scans. The CT values of SPNs on enhanced weighted average and virtual non-enhanced images were compared by using Liver VNC processing unit in terms of their diagnostic accuracy for distinguishing malignant and benign nodules with a 20 HU threshold. Diagnostic accuracy was compared. In 28 patients of all patients, image noise and quality score of the non-enhanced and virtual non-enhanced images were compared, and radiation doses of each patient were recorded. The paired t test was used to analyze the noise difference between the plain scan and virtual non-enhanced scan. The Mann-Whitney U test. was used to analyze statistically significant differences of the image quality score and radiation dose between the non-enhanced scan and virtual non-enhanced scan. Results: The sensitivity, specificity and accuracy for distinguishing benign and malignant nodules by using the virtual non-enhanced image of were 89.7% (35/39), 72.2% (13/18), 84.2% (48/57) respectively. The noise of common CT and virtual non- enhanced images were (8.49±1.94) HU and (10.14±2.18) HU, and there were statistically difference (t=9.45, P 0.05). The radiation doses of common CT and DECT were (3.72±0.48) mSv and (3.78±0.45) mSv, and there were no statistical difference (U= 350.50, P>0.05). Conclusion: DECT by using virtual non-enhanced images is useful tool to distinguish the benign and malignant SPN without additional radiation dose. (authors)

  4. Pathomorphism of spiral tibial fractures in computed tomography imaging.

    Science.gov (United States)

    Guzik, Grzegorz

    2011-01-01

    Spiral fractures of the tibia are virtually homogeneous with regard to their pathomorphism. The differences that are seen concern the level of fracture of the fibula, and, to a lesser extent, the level of fracture of the tibia, the length of fracture cleft, and limb shortening following the trauma. While conventional radiographs provide sufficient information about the pathomorphism of fractures, computed tomography can be useful in demonstrating the spatial arrangement of bone fragments and topography of soft tissues surrounding the fracture site. Multiple cross-sectional computed tomography views of spiral fractures of the tibia show the details of the alignment of bone chips at the fracture site, axis of the tibial fracture cleft, and topography of soft tissues that are not visible on standard radiographs. A model of a spiral tibial fracture reveals periosteal stretching with increasing spiral and longitudinal displacement. The cleft in tibial fractures has a spiral shape and its line is invariable. Every spiral fracture of both crural bones results in extensive damage to the periosteum and may damage bellies of the long flexor muscle of toes, flexor hallucis longus as well as the posterior tibial muscle. Computed tomography images of spiral fractures of the tibia show details of damage that are otherwise invisible on standard radiographs. Moreover, CT images provide useful information about the spatial location of the bone chips as well as possible threats to soft tissues that surround the fracture site. Every spiral fracture of the tibia is associated with disruption of the periosteum. 1. Computed tomography images of spiral fractures of the tibia show details of damage otherwise invisible on standard radiographs, 2. The sharp end of the distal tibial chip can damage the tibialis posterior muscle, long flexor muscles of the toes and the flexor hallucis longus, 3. Every spiral fracture of the tibia is associated with disruption of the periosteum.

  5. Advanced server virtualization VMware and Microsoft platforms in the virtual data center

    CERN Document Server

    Marshall, David; McCrory, Dave

    2006-01-01

    Executives of IT organizations are compelled to quickly implement server virtualization solutions because of significant cost savings. However, most IT professionals tasked with deploying virtualization solutions have little or no experience with the technology. This creates a high demand for information on virtualization and how to properly implement it in a datacenter. Advanced Server Virtualization: VMware® and Microsoft® Platforms in the Virtual Data Center focuses on the core knowledge needed to evaluate, implement, and maintain an environment that is using server virtualization. This boo

  6. A Virtual Class Calculus

    DEFF Research Database (Denmark)

    Ernst, Erik; Ostermann, Klaus; Cook, William Randall

    2006-01-01

    Virtual classes are class-valued attributes of objects. Like virtual methods, virtual classes are defined in an object's class and may be redefined within subclasses. They resemble inner classes, which are also defined within a class, but virtual classes are accessed through object instances...... model for virtual classes has been a long-standing open question. This paper presents a virtual class calculus, vc, that captures the essence of virtual classes in these full-fledged programming languages. The key contributions of the paper are a formalization of the dynamic and static semantics of vc...

  7. [Establishment of Schatzker classification digital models of tibial plateau fractures and its application on virtual surgery].

    Science.gov (United States)

    Liu, Yong-gang; Zuo, Li-xin; Pei, Guo-xian; Dai, Ke; Sang, Jing-wei

    2013-08-20

    To explore the establishment of Schatzker classification digital model of tibial plateau fractures and its application in virtual surgery. Proximal tibial of one healthy male volunteer was examined with 64-slice spiral computed tomography (CT). The data were processed by software Mimics 10.01 and a model of proximal tibia was reconstructed. According to the Schatzker classification criteria of tibial plateau fractures, each type of fracture model was simulated.Screen-captures of fracture model were saved from different directions.Each type of fracture model was exported as video mode.Fracture model was imported into FreeForm modeling system.With a force feedback device, a surgeon could conduct virtual fracture operation simulation.Utilizing the GHOST of FreeForm modeling system, the software of virtual cutting, fracture reduction and fixation was developed.With a force feedback device PHANTOM, a surgeon could manipulate virtual surgical instruments and fracture classification model and simulate surgical actions such as assembly of surgical instruments, drilling, implantation of screw, reduction of fracture, bone grafting and fracture fixation, etc. The digital fracture model was intuitive, three-dimensional and realistic and it had excellent visual effect.Fracture could be observed and charted from optional direction and angle.Fracture model could rotate 360 ° in the corresponding video mode. The virtual surgical environment had a strong sense of reality, immersion and telepresence as well as good interaction and force feedback function in the FreeForm modeling system. The user could make the corresponding decisions about surgical method and choice of internal fixation according to the specific type of tibial plateau fracture as well as repeated operational practice in virtual surgery system. The digital fracture model of Schatzker classification is intuitive, three-dimensional, realistic and dynamic. The virtual surgery systems of Schatzker classifications make

  8. The Virtual Tablet: Virtual Reality as a Control System

    Science.gov (United States)

    Chronister, Andrew

    2016-01-01

    In the field of human-computer interaction, Augmented Reality (AR) and Virtual Reality (VR) have been rapidly growing areas of interest and concerted development effort thanks to both private and public research. At NASA, a number of groups have explored the possibilities afforded by AR and VR technology, among which is the IT Advanced Concepts Lab (ITACL). Within ITACL, the AVR (Augmented/Virtual Reality) Lab focuses on VR technology specifically for its use in command and control. Previous work in the AVR lab includes the Natural User Interface (NUI) project and the Virtual Control Panel (VCP) project, which created virtual three-dimensional interfaces that users could interact with while wearing a VR headset thanks to body- and hand-tracking technology. The Virtual Tablet (VT) project attempts to improve on these previous efforts by incorporating a physical surrogate which is mirrored in the virtual environment, mitigating issues with difficulty of visually determining the interface location and lack of tactile feedback discovered in the development of previous efforts. The physical surrogate takes the form of a handheld sheet of acrylic glass with several infrared-range reflective markers and a sensor package attached. Using the sensor package to track orientation and a motion-capture system to track the marker positions, a model of the surrogate is placed in the virtual environment at a position which corresponds with the real-world location relative to the user's VR Head Mounted Display (HMD). A set of control mechanisms is then projected onto the surface of the surrogate such that to the user, immersed in VR, the control interface appears to be attached to the object they are holding. The VT project was taken from an early stage where the sensor package, motion-capture system, and physical surrogate had been constructed or tested individually but not yet combined or incorporated into the virtual environment. My contribution was to combine the pieces of

  9. Application of super-virtual seismic refraction interferometry to enhance first arrivals: A case study from Saudi Arabia

    KAUST Repository

    Alshuhail, Abdulrahman Abdullatif Abdulrahman

    2012-01-01

    Complex near-surface anomalies are one of the main onshore challenges facing seismic data processors. Refraction tomography is becoming a common technology to estimate an accurate near-surface velocity model. This process involves picking the first arrivals of refracted waves. One of the main challenges with refraction tomography is the low signal-to-noise ratio characterizing the first-break waveform arrivals, especially for the far-offset receivers. This is especially evident in data recorded using reflection acquisition geometry. This low signal-to-noise ratio is caused by signal attenuation due to geometrical spreading of the seismic wavefield, near-surface-generated noise, and amplitude absorption. Super-virtual refraction interferometry improves the quality of the first-break picks by enhancing the amplitude of the refracted waves and attenuating the amplitude of the random noise.

  10. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  11. Virtual projects

    DEFF Research Database (Denmark)

    Svejvig, Per; Commisso, Trine Hald

    2012-01-01

    that the best practice knowledge has not permeated sufficiently to the practice. Furthermore, the appropriate application of information and communication technology (ICT) remains a big challenge, and finally project managers are not sufficiently trained in organizing and conducting virtual projects....... The overall implications for research and practice are to acknowledge virtual project management as very different to traditional project management and to address this difference.......Virtual projects are common with global competition, market development, and not least the financial crisis forcing organizations to reduce their costs drastically. Organizations therefore have to place high importance on ways to carry out virtual projects and consider appropriate practices...

  12. A Virtual Clinical Trial of FDG-PET Imaging of Breast Cancer: Effect of Variability on Response Assessment1

    OpenAIRE

    Harrison, Robert L; Elston, Brian F; Doot, Robert K; Lewellen, Thomas K; Mankoff, David A; Kinahan, Paul E

    2014-01-01

    INTRODUCTION: There is growing interest in using positron emission tomography (PET) standardized uptake values (SUVs) to assess tumor response to therapy. However, many error sources compromise the ability to detect SUV changes. We explore relationships between these errors and overall SUV variability. METHODS: We used simulations in a virtual clinical trial framework to study impacts of error sources from scanning and analysis effects on assessment of SUV changes. We varied tumor diameter, s...

  13. Transforming Virtual Teams

    DEFF Research Database (Denmark)

    Bjørn, Pernille

    2005-01-01

    Investigating virtual team collaboration in industry using grounded theory this paper presents the in-dept analysis of empirical work conducted in a global organization of 100.000 employees where a global virtual team with participants from Sweden, United Kingdom, Canada, and North America were...... studied. The research question investigated is how collaboration is negotiated within virtual teams? This paper presents findings concerning how collaboration is negotiated within a virtual team and elaborate the difficulties due to invisible articulation work and managing multiple communities...... in transforming the virtual team into a community. It is argued that translucence in communication structures within the virtual team and between team and management is essential for engaging in a positive transformation process of trustworthiness supporting the team becoming a community, managing the immanent...

  14. Trust and virtual worlds

    DEFF Research Database (Denmark)

    Ess, Charles; Thorseth, May

    2011-01-01

    We collect diverse philosophical analyses of the issues and problems clustering around trust online with specific attention to establishing trust in virtual environments. The book moves forward important discussions of how virtual worlds and virtuality are to be defined and understood; the role o...... by virtuality, such as virtual child pornography. The introduction further develops a philosophical anthropology, rooted in Kantian ethics, phenomenology, virtue ethics, and feminist perspectives, that grounds a specific approach to ethical issues in virtual environments....

  15. Virtual water: Virtuous impact? : the unsteady state of virtual water

    NARCIS (Netherlands)

    Roth, D.; Warner, J.F.

    2008-01-01

    Virtual water,” water needed for crop production, is now being mainstreamed in the water policy world. Relying on virtual water in the form of food imports is increasingly recommended as good policy for water-scarce areas. Virtual water globalizes discussions on water scarcity, ecological

  16. Evolution-based Virtual Content Insertion with Visually Virtual Interactions in Videos

    Science.gov (United States)

    Chang, Chia-Hu; Wu, Ja-Ling

    With the development of content-based multimedia analysis, virtual content insertion has been widely used and studied for video enrichment and multimedia advertising. However, how to automatically insert a user-selected virtual content into personal videos in a less-intrusive manner, with an attractive representation, is a challenging problem. In this chapter, we present an evolution-based virtual content insertion system which can insert virtual contents into videos with evolved animations according to predefined behaviors emulating the characteristics of evolutionary biology. The videos are considered not only as carriers of message conveyed by the virtual content but also as the environment in which the lifelike virtual contents live. Thus, the inserted virtual content will be affected by the videos to trigger a series of artificial evolutions and evolve its appearances and behaviors while interacting with video contents. By inserting virtual contents into videos through the system, users can easily create entertaining storylines and turn their personal videos into visually appealing ones. In addition, it would bring a new opportunity to increase the advertising revenue for video assets of the media industry and online video-sharing websites.

  17. Theft of Virtual Property — Towards Security Requirements for Virtual Worlds

    Science.gov (United States)

    Beyer, Anja

    The article is focused to introduce the topic of information technology security for Virtual Worlds to a security experts’ audience. Virtual Worlds are Web 2.0 applications where the users cruise through the world with their individually shaped avatars to find either amusement, challenges or the next best business deal. People do invest a lot of time but beyond they invest in buying virtual assets like fantasy witcheries, wepaons, armour, houses, clothes,...etc with the power of real world money. Although it is called “virtual” (which is often put on the same level as “not existent”) there is a real value behind it. In November 2007 dutch police arrested a seventeen years old teenager who was suspicted to have stolen virtual items in a Virtual World called Habbo Hotel [Reuters07]. In order to successfully provide security mechanisms into Virtual Worlds it is necessarry to fully understand the domain for which the security mechansims are defined. As Virtual Worlds must be clasified into the domain of Social Software the article starts with an overview of how to understand Web 2.0 and gives a short introduction to Virtual Worlds. The article then provides a consideration of assets of Virtual Worlds participants, describes how these assets can be threatened and gives an overview of appopriate security requirements and completes with an outlook of possible countermeasures.

  18. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography; Avaliacao de dose em procedimentos especiais de fluoroscopia: histerossalpingografia e dacriocistografia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Cintya Carolina Barbosa

    2006-04-15

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  19. Interaction with virtual crowd in Immersive and semi‐Immersive Virtual Reality systems

    OpenAIRE

    Kyriakou, Marios; Pan, Xueni; Chrysanthou, Yiorgos

    2016-01-01

    This study examines attributes of virtual human behavior that may increase the plausibility of a simulated crowd and affect the user's experience in Virtual Reality. Purpose-developed experiments in both Immersive and semi-Immersive Virtual Reality systems queried the impact of collision and basic interaction between real-users and the virtual crowd and their effect on the apparent realism and ease of navigation within Virtual Reality (VR). Participants' behavior and subjective measurements i...

  20. Virtual anthropology: useful radiological tools for age assessment in clinical forensic medicine and thanatology.

    Science.gov (United States)

    Dedouit, Fabrice; Saint-Martin, Pauline; Mokrane, Fatima-Zohra; Savall, Frédéric; Rousseau, Hervé; Crubézy, Eric; Rougé, Daniel; Telmon, Norbert

    2015-09-01

    Virtual anthropology consists of the introduction of modern slice imaging to biological and forensic anthropology. Thanks to this non-invasive scientific revolution, some classifications and staging systems, first based on dry bone analysis, can be applied to cadavers with no need for specific preparation, as well as to living persons. Estimation of bone and dental age is one of the possibilities offered by radiology. Biological age can be estimated in clinical forensic medicine as well as in living persons. Virtual anthropology may also help the forensic pathologist to estimate a deceased person's age at death, which together with sex, geographical origin and stature, is one of the important features determining a biological profile used in reconstructive identification. For this forensic purpose, the radiological tools used are multislice computed tomography and, more recently, X-ray free imaging techniques such as magnetic resonance imaging and ultrasound investigations. We present and discuss the value of these investigations for age estimation in anthropology.

  1. Turbocharging Quantum Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Gamble, John King [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Nielsen, Erik [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Maunz, Peter Lukas Wilhelm [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Scholten, Travis L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Rudinger, Kenneth Michael [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography suffers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. We describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more effectively detect and characterize quantum noise using carefully tailored ensembles of input states.

  2. Designing Virtual Worlds

    DEFF Research Database (Denmark)

    Gürsimsek, Remzi Ates

    2014-01-01

    The online social platforms known as virtual worlds present their users various affordances for avatar based co-presence, social interaction and provide tools for collaborative content creation, including objects, textures and animations. The users of these worlds navigate their avatars as personal...... the audio-visual characteristics of designing in multi-user virtual environments generate experiential, interpersonal and textual meaning potentials....... mediators in 3D virtual space to collaborate and co-design the digital content. These co-designers are also the residents of these worlds, as they socialize by building inworld friendships. This article presents a social semiotic analysis of the three-dimensional virtual places and artifacts in the virtual...

  3. Server virtualization solutions

    OpenAIRE

    Jonasts, Gusts

    2012-01-01

    Currently in the information technology sector that is responsible for a server infrastructure is a huge development in the field of server virtualization on x86 computer architecture. As a prerequisite for such a virtualization development is growth in server productivity and underutilization of available computing power. Several companies in the market are working on two virtualization architectures – hypervizor and hosting. In this paper several of virtualization products that use host...

  4. Virtual Trackballs Revisited

    OpenAIRE

    Henriksen, Knud; Sporring, Jon; Hornbæk, Kasper

    2004-01-01

    Udgivelsesdato: March/April Rotation of three-dimensional objects by a two-dimensional mouse is a typical task in computer-aided design, operation simulations, and desktop virtual reality. The most commonly used rotation technique is a virtual trackball surrounding the object and operated by the mouse pointer. This article reviews and provides a mathematical foundation for virtual trackballs. The first, but still popular, virtual trackball was described by Chen et al. [CHECK END OF SENTENC...

  5. Interactive Virtual Cinematography

    OpenAIRE

    Burelli, Paolo

    2012-01-01

    A virtual camera represents the point-of-view of the player through which sheperceives the game world and gets feedback on her actions. Thus, the virtualcamera plays a vital role in 3D computer games and aects player experienceand enjoyability in games. Interactive virtual cinematography is the process ofvisualising the content of a virtual environment by positioning and animatingthe virtual camera in the context of interactive applications such as a computergame.Camera placement and animatio...

  6. Virtual Reflexes

    OpenAIRE

    Jonker, Catholijn; Broekens, Joost; Plaat, Aske

    2014-01-01

    Virtual Reality is used successfully to treat people for regular phobias. A new challenge is to develop Virtual Reality Exposure Training for social skills. Virtual actors in such systems have to show appropriate social behavior including emotions, gaze, and keeping distance. The behavior must be realistic and real-time. Current approaches consist of four steps: 1) trainee social signal detection, 2) cognitive-affective interpretation, 3) determination of the appropriate bodily responses, and...

  7. Virtual medicine: Utilization of the advanced cardiac imaging patient avatar for procedural planning and facilitation.

    Science.gov (United States)

    Shinbane, Jerold S; Saxon, Leslie A

    Advances in imaging technology have led to a paradigm shift from planning of cardiovascular procedures and surgeries requiring the actual patient in a "brick and mortar" hospital to utilization of the digitalized patient in the virtual hospital. Cardiovascular computed tomographic angiography (CCTA) and cardiovascular magnetic resonance (CMR) digitalized 3-D patient representation of individual patient anatomy and physiology serves as an avatar allowing for virtual delineation of the most optimal approaches to cardiovascular procedures and surgeries prior to actual hospitalization. Pre-hospitalization reconstruction and analysis of anatomy and pathophysiology previously only accessible during the actual procedure could potentially limit the intrinsic risks related to time in the operating room, cardiac procedural laboratory and overall hospital environment. Although applications are specific to areas of cardiovascular specialty focus, there are unifying themes related to the utilization of technologies. The virtual patient avatar computer can also be used for procedural planning, computational modeling of anatomy, simulation of predicted therapeutic result, printing of 3-D models, and augmentation of real time procedural performance. Examples of the above techniques are at various stages of development for application to the spectrum of cardiovascular disease processes, including percutaneous, surgical and hybrid minimally invasive interventions. A multidisciplinary approach within medicine and engineering is necessary for creation of robust algorithms for maximal utilization of the virtual patient avatar in the digital medical center. Utilization of the virtual advanced cardiac imaging patient avatar will play an important role in the virtual health care system. Although there has been a rapid proliferation of early data, advanced imaging applications require further assessment and validation of accuracy, reproducibility, standardization, safety, efficacy, quality

  8. Optical tomography of tissues

    International Nuclear Information System (INIS)

    Zimnyakov, D A; Tuchin, Valerii V

    2002-01-01

    Methods of optical tomography of biological tissues are considered, which include pulse-modulation and frequency-modulation tomography, diffusion tomography with the use of cw radiation sources, optical coherent tomography, speckle-correlation tomography of nonstationary media, and optoacoustic tomography. The method for controlling the optical properties of tissues is studied from the point of view of increasing a probing depth in optical coherent tomography. The modern state and prospects of the development of optical tomography are discussed. (review)

  9. Interlaboratory Comparison of a physical and a virtual assembly measured by CT

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo

    2018-01-01

    In a comparison including 20 laboratories, a physical as well as a virtual assembly provided as two data sets were used to investigate measuring and post-processing approaches in Computed Tomography, CT. Different procedures were used in the comparison including one simulating in-line measurement....... The comparison demonstrated that: (i) a tangible improvement in the use of CT compared to previous comparisons; (ii) most of the participants were able to reduce their scanning time by more than 70% without increasing the length measurement errors; and (iii) most of the participants can further reduce...... their uncertainties, thereby reducing the tolerance size that can be inspected using CT in industry....

  10. The impact of virtual simulation in palliative radiotherapy for non-small-cell lung cancer

    International Nuclear Information System (INIS)

    McJury, Mark; Fisher, Patricia M.; Pledge, Simon; Brown, Gillian; Anthony, Catherine; Hatton, Matthew Q.; Conway, John; Robinson, Martin H.

    2001-01-01

    Background and purpose: Radiotherapy is widely used to palliate local symptoms in non-small-cell lung cancer. Using conventional X-ray simulation, it is often difficult to accurately localize the extent of the tumour. We report a randomized, double blind trial comparing target localization with conventional and virtual simulation. Methods: Eighty-six patients underwent both conventional and virtual simulation. The conventional simulator films were compared with digitally reconstructed radiographs (DRRs) produced from the computed tomography (CT) data. The treatment fields defined by the clinicians using each modality were compared in terms of field area, position and the implications for target coverage. Results: Comparing fields defined by each study arm, there was a major mis-match in coverage between fields in 66.2% of cases, and a complete match in only 5.2% of cases. In 82.4% of cases, conventional simulator fields were larger (mean 24.5±5.1% (95% confidence interval)) than CT-localized fields, potentially contributing to a mean target under-coverage of 16.4±3.5% and normal tissue over-coverage of 25.4±4.2%. Conclusions: CT localization and virtual simulation allow more accurate definition of the target volume. This could enable a reduction in geographical misses, while also reducing treatment-related toxicity

  11. Nanoroses of nickel oxides: Synthesis, electron tomography study, and application in CO oxidation and energy storage

    KAUST Repository

    Fihri, Aziz

    2012-04-11

    Nickel oxide and mixed-metal oxide structures were fabricated by using microwave irradiation in pure water. The nickel oxide self-assembled into unique rose-shaped nanostructures. These nickel oxide roses were studied by performing electron tomography with virtual cross-sections through the particles to understand their morphology from their interior to their surface. These materials exhibited promising performance as nanocatalysts for CO oxidation and in energy storage devices. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. [Virtual + 1] * Reality

    Science.gov (United States)

    Beckhaus, Steffi

    Virtual Reality aims at creating an artificial environment that can be perceived as a substitute to a real setting. Much effort in research and development goes into the creation of virtual environments that in their majority are perceivable only by eyes and hands. The multisensory nature of our perception, however, allows and, arguably, also expects more than that. As long as we are not able to simulate and deliver a fully sensory believable virtual environment to a user, we could make use of the fully sensory, multi-modal nature of real objects to fill in for this deficiency. The idea is to purposefully integrate real artifacts into the application and interaction, instead of dismissing anything real as hindering the virtual experience. The term virtual reality - denoting the goal, not the technology - shifts from a core virtual reality to an “enriched” reality, technologically encompassing both the computer generated and the real, physical artifacts. Together, either simultaneously or in a hybrid way, real and virtual jointly provide stimuli that are perceived by users through their senses and are later formed into an experience by the user's mind.

  13. Virtual Vision

    Science.gov (United States)

    Terzopoulos, Demetri; Qureshi, Faisal Z.

    Computer vision and sensor networks researchers are increasingly motivated to investigate complex multi-camera sensing and control issues that arise in the automatic visual surveillance of extensive, highly populated public spaces such as airports and train stations. However, they often encounter serious impediments to deploying and experimenting with large-scale physical camera networks in such real-world environments. We propose an alternative approach called "Virtual Vision", which facilitates this type of research through the virtual reality simulation of populated urban spaces, camera sensor networks, and computer vision on commodity computers. We demonstrate the usefulness of our approach by developing two highly automated surveillance systems comprising passive and active pan/tilt/zoom cameras that are deployed in a virtual train station environment populated by autonomous, lifelike virtual pedestrians. The easily reconfigurable virtual cameras distributed in this environment generate synthetic video feeds that emulate those acquired by real surveillance cameras monitoring public spaces. The novel multi-camera control strategies that we describe enable the cameras to collaborate in persistently observing pedestrians of interest and in acquiring close-up videos of pedestrians in designated areas.

  14. Tangible interfaces in virtual environments, case study: Instituto de Engenharia Nuclear Virtual

    Energy Technology Data Exchange (ETDEWEB)

    Santo, Andre Cotelli do E.; Mol, Antonio Carlos A.; Pinto, Emanuele Oliveira; Melo, Joao Victor da C.; Paula, Vanessa Marcia de; Freitas, Victor Goncalves Gloria [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Machado, Daniel Mol [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Instituto Alberto Luiz Coimbra

    2015-07-01

    Virtual Reality (VR) techniques allow the creation of realistic representations of an individual. These technologies are being applied in several fields such as training, simulations, virtual experiments and new applications are constantly being found. This work aims to present an interactive system in virtual environments without the use of peripherals typically found in computers such as mouse and keyboard. Through the movement of head and hands it is possible to control and navigate the virtual character (avatar) in a virtual environment, an improvement in the man-machine integration. The head movements are recognized using a virtual helmet with a tracking system. An infrared camera detects the position of infrared LEDs located in the operator's head and places the vision of the virtual character in accordance with the operator's vision. The avatar control is performed by a system that detects the movement of the hands, using infrared sensors, allowing the user to move it in the virtual environment. This interaction system was implemented in the virtual model of the Instituto de Engenharia Nuclear (IEN), which is located on the Ilha do Fundao - Rio de Janeiro - Brazil. This three-dimensional environment, in which avatars can move and interact according to the user movements, gives a feeling of realism to the operator. The results show an interface that allows a higher degree of immersion of the operator in the virtual environment, promoting a more engaging and dynamic way of working. (author)

  15. Tangible interfaces in virtual environments, case study: Instituto de Engenharia Nuclear Virtual

    International Nuclear Information System (INIS)

    Santo, Andre Cotelli do E.; Mol, Antonio Carlos A.; Pinto, Emanuele Oliveira; Melo, Joao Victor da C.; Paula, Vanessa Marcia de; Freitas, Victor Goncalves Gloria; Machado, Daniel Mol

    2015-01-01

    Virtual Reality (VR) techniques allow the creation of realistic representations of an individual. These technologies are being applied in several fields such as training, simulations, virtual experiments and new applications are constantly being found. This work aims to present an interactive system in virtual environments without the use of peripherals typically found in computers such as mouse and keyboard. Through the movement of head and hands it is possible to control and navigate the virtual character (avatar) in a virtual environment, an improvement in the man-machine integration. The head movements are recognized using a virtual helmet with a tracking system. An infrared camera detects the position of infrared LEDs located in the operator's head and places the vision of the virtual character in accordance with the operator's vision. The avatar control is performed by a system that detects the movement of the hands, using infrared sensors, allowing the user to move it in the virtual environment. This interaction system was implemented in the virtual model of the Instituto de Engenharia Nuclear (IEN), which is located on the Ilha do Fundao - Rio de Janeiro - Brazil. This three-dimensional environment, in which avatars can move and interact according to the user movements, gives a feeling of realism to the operator. The results show an interface that allows a higher degree of immersion of the operator in the virtual environment, promoting a more engaging and dynamic way of working. (author)

  16. Virtual reality system for diagnosis and therapeutic planning of cerebral aneurysms.

    Science.gov (United States)

    Mo, Da-peng; Bao, Sheng-de; Li, Liang; Yi, Zhi-qiang; Zhang, Jia-yong; Zhang, Yang

    2010-08-01

    The virtual reality (VR) system can provide the neurosurgeon to intuitively interact with and manipulate the three dimensional (3-D) image similarly to manipulate a real object. It was seldom reported that the system was used in diagnosis and treatment of cerebral aneurysms. This study aimed to investigate the application of VR system in diagnosis and therapeutic planning of cerebral aneurysms. A total of 24 cases of cerebral aneurysms were enrolled in this study from 2006 to 2008, which diagnosed by 3-D digital subtraction angiography (3D-DSA) or VR-based computed tomography angiographies (CTA). The VR system and 3D-DSA system were used to observe and measure aneurysms and the adjacent vessels. The data of observation and measurements were compared between VR image and 3D-DSA image. All the patients underwent surgical plan and simulated neurosurgical procedures in the VR system. There were 28 aneurysms detected in VR system and 3D-DSA system. The VR system generated clear and vivid 3-D virtual images which clearly displayed the location and size of the aneurysms and their precise anatomical spatial relations to the parent arteries and skull. The location, size and shape of the aneurysms and their anatomical relationship with the adjacent vessels were similar between 3-D virtual image and 3D-DSA, but the spatial relationship between aneurysms and skull only been displayed by VR system. This VR system also could simulate simple surgical procedures and surgical environments. The VR system can provide a highly effective way to provide precise imaging details as same as 3D-DSA system and assist the diagnosis of cerebral aneurysms with virtual 3-D data based on CTA. It significantly enhances the chosen therapeutic strategy of cerebral aneurysms.

  17. Virtual volatility

    Science.gov (United States)

    Silva, A. Christian; Prange, Richard E.

    2007-03-01

    We introduce the concept of virtual volatility. This simple but new measure shows how to quantify the uncertainty in the forecast of the drift component of a random walk. The virtual volatility also is a useful tool in understanding the stochastic process for a given portfolio. In particular, and as an example, we were able to identify mean reversion effect in our portfolio. Finally, we briefly discuss the potential practical effect of the virtual volatility on an investor asset allocation strategy.

  18. Computerized tomography

    International Nuclear Information System (INIS)

    Rubashov, I.B.

    1985-01-01

    Operating principle is described for the devices of computerized tomography used in medicine for diagnosis of brain diseases. Computerized tomography is considered as a part of computerized diagnosis, as a part of information science. It is shown that computerized tomography is a real existed field of investigations in medicine and industrial production

  19. Virtual laboratories : comparability of real and virtual environments for environmental psychology

    NARCIS (Netherlands)

    Kort, de Y.A.W.; IJsselsteijn, W.A.; Kooijman, J.M.A.; Schuurmans, Y.

    2003-01-01

    Virtual environments have the potential to become important new research tools in environment behavior research. They could even become the future (virtual) laboratories, if reactions of people to virtual environments are similar to those in real environments. The present study is an exploration of

  20. High availability using virtualization

    International Nuclear Information System (INIS)

    Calzolari, Federico; Arezzini, Silvia; Ciampa, Alberto; Mazzoni, Enrico; Domenici, Andrea; Vaglini, Gigliola

    2010-01-01

    High availability has always been one of the main problems for a data center. Till now high availability was achieved by host per host redundancy, a highly expensive method in terms of hardware and human costs. A new approach to the problem can be offered by virtualization. Using virtualization, it is possible to achieve a redundancy system for all the services running on a data center. This new approach to high availability allows the running virtual machines to be distributed over a small number of servers, by exploiting the features of the virtualization layer: start, stop and move virtual machines between physical hosts. The 3RC system is based on a finite state machine, providing the possibility to restart each virtual machine over any physical host, or reinstall it from scratch. A complete infrastructure has been developed to install operating system and middleware in a few minutes. To virtualize the main servers of a data center, a new procedure has been developed to migrate physical to virtual hosts. The whole Grid data center SNS-PISA is running at the moment in virtual environment under the high availability system.

  1. Virtual reality in education

    OpenAIRE

    Minocha, Shailey; Tudor, Ana-Despina

    2017-01-01

    In this workshop-presentation, we described the evolution of virtual reality technologies and our research from 3D virtual worlds, 3D virtual environments built in gaming environments such as Unity 3D, 360-degree videos, and mobile virtual reality via Google Expeditions. For each of these four technologies, we discussed the affordances of the technologies and how they contribute towards learning and teaching. We outlined the significance of students being aware of the different virtual realit...

  2. Virtual Reality: Principles and Applications

    OpenAIRE

    MÉRIENNE , Frédéric

    2017-01-01

    Virtual reality aims at immersing a user in a virtual environment. Dedicated virtual reality technologies of human–computer interaction enable to make the link between the user and a virtual environment in capturing the user’s motion, acting on his senses as well as computing the virtual experience in real-time. The immersion in virtual environment is evaluated through the user’s perception and reaction. Virtual reality is used in a large variety of application domains which need multisensory...

  3. Virtual Organizations: Beyond Network Organization

    Directory of Open Access Journals (Sweden)

    Liviu Gabriel CRETU

    2006-01-01

    Full Text Available One of the most used buzz-words in (e-business literature of the last decade is virtual organization. The term "virtual" can be identified in all sorts of combinations regarding the business world. From virtual products to virtual processes or virtual teams, everything that is “touched” by the computer’s processing power instantly becomes virtual. Moreover, most of the literature treats virtual and network organizations as being synonyms. This paper aims to draw a much more distinctive line between the two concepts. Providing a more coherent description of what virtual organization might be is also one of our intentions.

  4. Virtual Reference Services.

    Science.gov (United States)

    Brewer, Sally

    2003-01-01

    As the need to access information increases, school librarians must create virtual libraries. Linked to reliable reference resources, the virtual library extends the physical collection and library hours and lets students learn to use Web-based resources in a protected learning environment. The growing number of virtual schools increases the need…

  5. Game-Based Virtual Worlds as Decentralized Virtual Activity Systems

    Science.gov (United States)

    Scacchi, Walt

    There is widespread interest in the development and use of decentralized systems and virtual world environments as possible new places for engaging in collaborative work activities. Similarly, there is widespread interest in stimulating new technological innovations that enable people to come together through social networking, file/media sharing, and networked multi-player computer game play. A decentralized virtual activity system (DVAS) is a networked computer supported work/play system whose elements and social activities can be both virtual and decentralized (Scacchi et al. 2008b). Massively multi-player online games (MMOGs) such as World of Warcraft and online virtual worlds such as Second Life are each popular examples of a DVAS. Furthermore, these systems are beginning to be used for research, deve-lopment, and education activities in different science, technology, and engineering domains (Bainbridge 2007, Bohannon et al. 2009; Rieber 2005; Scacchi and Adams 2007; Shaffer 2006), which are also of interest here. This chapter explores two case studies of DVASs developed at the University of California at Irvine that employ game-based virtual worlds to support collaborative work/play activities in different settings. The settings include those that model and simulate practical or imaginative physical worlds in different domains of science, technology, or engineering through alternative virtual worlds where players/workers engage in different kinds of quests or quest-like workflows (Jakobsson 2006).

  6. VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients

    Science.gov (United States)

    Ding, Aiping; Gao, Yiming; Liu, Haikuan; Caracappa, Peter F.; Long, Daniel J.; Bolch, Wesley E.; Liu, Bob; Xu, X. George

    2015-07-01

    This paper describes the development and testing of VirtualDose—a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the ‘software as a service (SaaS)’ delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose’s functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT—two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations.

  7. VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients

    International Nuclear Information System (INIS)

    Ding, Aiping; Gao, Yiming; Liu, Haikuan; Caracappa, Peter F; Xu, X George; Long, Daniel J; Bolch, Wesley E; Liu, Bob

    2015-01-01

    This paper describes the development and testing of VirtualDose—a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the ‘software as a service (SaaS)’ delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose’s functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT—two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations. (paper)

  8. Virtualization A Manager's Guide

    CERN Document Server

    Kusnetzky, Dan

    2011-01-01

    What exactly is virtualization? As this concise book explains, virtualization is a smorgasbord of technologies that offer organizations many advantages, whether you're managing extremely large stores of rapidly changing data, scaling out an application, or harnessing huge amounts of computational power. With this guide, you get an overview of the five main types of virtualization technology, along with information on security, management, and modern use cases. Topics include: Access virtualization-Allows access to any application from any deviceApplication virtualization-Enables applications

  9. Virtual reality - aesthetic consequences

    OpenAIRE

    Benda, Lubor

    2014-01-01

    In the present work we study aesthetic consequences of virtual reality. Exploring the fringe between fictional and virtual is one of the key goals, that will be achieved through etymologic and technologic definition of both fiction and virtual reality, fictional and virtual worlds. Both fiction and virtual reality will be then studied from aesthetic distance and aesthetic pleasure point of view. At the end, we will see the main difference as well as an common grounds between fiction and virtu...

  10. Virtual stress testing of fracture stability in soldiers with severely comminuted tibial fractures.

    Science.gov (United States)

    Petfield, Joseph L; Hayeck, Garry T; Kopperdahl, David L; Nesti, Leon J; Keaveny, Tony M; Hsu, Joseph R

    2017-04-01

    Virtual stress testing (VST) provides a non-invasive estimate of the strength of a healing bone through a biomechanical analysis of a patient's computed tomography (CT) scan. We asked whether VST could improve management of patients who had a tibia fracture treated with external fixation. In a retrospective case-control study of 65 soldier-patients who had tibia fractures treated with an external fixator, we performed VST utilizing CT scans acquired prior to fixator removal. The strength of the healing bone and the amount of tissue damage after application of an overload were computed for various virtual loading cases. Logistic regression identified computed outcomes with the strongest association to clinical events related to nonunion within 2 months after fixator removal. Clinical events (n = 9) were associated with a low tibial strength for compression loading (p fracture patients who can safely resume weight bearing. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:805-811, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. User-centered virtual environment design for virtual rehabilitation

    Directory of Open Access Journals (Sweden)

    Rizzo Albert A

    2010-02-01

    Full Text Available Abstract Background As physical and cognitive rehabilitation protocols utilizing virtual environments transition from single applications to comprehensive rehabilitation programs there is a need for a new design cycle methodology. Current human-computer interaction designs focus on usability without benchmarking technology within a user-in-the-loop design cycle. The field of virtual rehabilitation is unique in that determining the efficacy of this genre of computer-aided therapies requires prior knowledge of technology issues that may confound patient outcome measures. Benchmarking the technology (e.g., displays or data gloves using healthy controls may provide a means of characterizing the "normal" performance range of the virtual rehabilitation system. This standard not only allows therapists to select appropriate technology for use with their patient populations, it also allows them to account for technology limitations when assessing treatment efficacy. Methods An overview of the proposed user-centered design cycle is given. Comparisons of two optical see-through head-worn displays provide an example of benchmarking techniques. Benchmarks were obtained using a novel vision test capable of measuring a user's stereoacuity while wearing different types of head-worn displays. Results from healthy participants who performed both virtual and real-world versions of the stereoacuity test are discussed with respect to virtual rehabilitation design. Results The user-centered design cycle argues for benchmarking to precede virtual environment construction, especially for therapeutic applications. Results from real-world testing illustrate the general limitations in stereoacuity attained when viewing content using a head-worn display. Further, the stereoacuity vision benchmark test highlights differences in user performance when utilizing a similar style of head-worn display. These results support the need for including benchmarks as a means of better

  12. User-centered virtual environment design for virtual rehabilitation.

    Science.gov (United States)

    Fidopiastis, Cali M; Rizzo, Albert A; Rolland, Jannick P

    2010-02-19

    As physical and cognitive rehabilitation protocols utilizing virtual environments transition from single applications to comprehensive rehabilitation programs there is a need for a new design cycle methodology. Current human-computer interaction designs focus on usability without benchmarking technology within a user-in-the-loop design cycle. The field of virtual rehabilitation is unique in that determining the efficacy of this genre of computer-aided therapies requires prior knowledge of technology issues that may confound patient outcome measures. Benchmarking the technology (e.g., displays or data gloves) using healthy controls may provide a means of characterizing the "normal" performance range of the virtual rehabilitation system. This standard not only allows therapists to select appropriate technology for use with their patient populations, it also allows them to account for technology limitations when assessing treatment efficacy. An overview of the proposed user-centered design cycle is given. Comparisons of two optical see-through head-worn displays provide an example of benchmarking techniques. Benchmarks were obtained using a novel vision test capable of measuring a user's stereoacuity while wearing different types of head-worn displays. Results from healthy participants who performed both virtual and real-world versions of the stereoacuity test are discussed with respect to virtual rehabilitation design. The user-centered design cycle argues for benchmarking to precede virtual environment construction, especially for therapeutic applications. Results from real-world testing illustrate the general limitations in stereoacuity attained when viewing content using a head-worn display. Further, the stereoacuity vision benchmark test highlights differences in user performance when utilizing a similar style of head-worn display. These results support the need for including benchmarks as a means of better understanding user outcomes, especially for patient

  13. Optical coherence tomography imaging of cranial meninges post brain injury in vivo

    Institute of Scientific and Technical Information of China (English)

    Woo June Choi; Ruikang K.Wang

    2017-01-01

    We report a new application of optical coherence tomography (OCT) to investigate the cranial meninges in an animal model of brain injury in vivo.The injury is induced in a mouse due to skull thinning,in which the repeated and excessive drilling exerts mechanical stress on the mouse brain through the skull,resulting in acute and mild brain injury.Transcranial OCT imaging reveals an interesting virtual space between the cranial meningeal layers post skull thinning,which is gradually closed within hours.The finding suggests a promise of OCT as an effective tool to monitor the mechanical trauma in the small animal model of brain injury.

  14. Trends in Virtualized User Environments

    Directory of Open Access Journals (Sweden)

    Diane Barrett

    2008-06-01

    Full Text Available Virtualized environments can make forensics investigation more difficult. Technological advances in virtualization tools essentially make removable media a PC that can be carried around in a pocket or around a neck. Running operating systems and applications this way leaves very little trace on the host system. This paper will explore all the newest methods for virtualized environments and the implications they have on the world of forensics. It will begin by describing and differentiating between software and hardware virtualization. It will then move on to explain the various methods used for server and desktop virtualization. Next, it will explain how virtualization affects the basic forensic process. Finally, it will describe the common methods to find virtualization artifacts and identify virtual activities that affect the examination process of certain virtualized user environments.

  15. Utility of multidetector row computed tomography and virtual bronchoscopy in evaluation of hemoptysis due to lung cancer

    Directory of Open Access Journals (Sweden)

    Sherif A.A. Mohamed

    2016-01-01

    Conclusion: MDCT angiography is a useful and non invasive method that allows a rapid and detailed identification of abnormal vasculature responsible for hemoptysis in patients with lung cancer. MDCT-generated virtual bronchoscopy is an accurate, and non invasive method for evaluating obstructions, endoluminal masses, and external compressions in patients with hemoptysis due to lung cancer.

  16. Sixteen-slice multidetector computed tomographic virtual cystoscopy in the evaluation of a patient with suspected bladder tumor and history of bladder carcinoma operation.

    Science.gov (United States)

    Basak, Muzaffer; Ozkurt, Huseyin; Tanriverdi, Orhan; Cay, Esra; Aydin, Mustafa; Miroglu, Cengiz

    2009-01-01

    The purpose of this study was to evaluate the use of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with suspected bladder tumors and histories of bladder carcinoma operation. Thirty-six patients (29 men and 7 women) with a mean age of 66 years (range, 24-88 years) with suspected bladder tumors and histories of bladder carcinoma operation were included in this prospective study. Virtual cystoscopy was performed by 16-slice multidetector CT scanner. The bladder was filled with diluted contrast material solution through a Foley catheter. Then, all patients underwent conventional cystoscopy examination. Two reviewers found 18 lesions detected by virtual cystoscopy by consensus, whereas 19 lesions were depicted by conventional cystoscopy. At virtual and conventional cystoscopies, the conditions of 3 patients, 2 with chronic inflammations and 1 with foreign body reaction, were wrongly diagnosed as tumors. At conventional cystoscopy, one patient's result was wrongly interpreted as normal. In pathologic evaluation, all tumors were diagnosed as transitional cell carcinoma. Bladder tumor can be noninvasively diagnosed using virtual cystoscopy. Use of virtual cystoscopy should be considered inpatients who present with hematuria or have histories of bladder carcinoma operation and are for follow-up because of its lesser complication risk and its being a less invasive, easily applied procedure without need of anesthesia. In the future, owing to the development of the CT technology and image processing technique, virtual cystoscopy may have a part in the detection of bladder cancer.

  17. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography; Avaliacao de dose em procedimentos especiais de fluoroscopia: histerossalpingografia e dacriocistografia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Cintya Carolina Barbosa

    2006-04-15

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  18. Dual-Energy Computed Tomography Angiography of the Lower Extremity Runoff: Impact of Noise-Optimized Virtual Monochromatic Imaging on Image Quality and Diagnostic Accuracy.

    Science.gov (United States)

    Wichmann, Julian L; Gillott, Matthew R; De Cecco, Carlo N; Mangold, Stefanie; Varga-Szemes, Akos; Yamada, Ricardo; Otani, Katharina; Canstein, Christian; Fuller, Stephen R; Vogl, Thomas J; Todoran, Thomas M; Schoepf, U Joseph

    2016-02-01

    The aim of this study was to evaluate the impact of a noise-optimized virtual monochromatic imaging algorithm (VMI+) on image quality and diagnostic accuracy at dual-energy computed tomography angiography (CTA) of the lower extremity runoff. This retrospective Health Insurance Portability and Accountability Act-compliant study was approved by the local institutional review board. We evaluated dual-energy CTA studies of the lower extremity runoff in 48 patients (16 women; mean age, 63.3 ± 13.8 years) performed on a third-generation dual-source CT system. Images were reconstructed with standard linear blending (F_0.5), VMI+, and traditional monochromatic (VMI) algorithms at 40 to 120 keV in 10-keV intervals. Vascular attenuation and image noise in 18 artery segments were measured; signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used to subjectively evaluate vascular attenuation and image noise. In a subgroup of 21 patients who underwent additional invasive catheter angiography, diagnostic accuracy for the detection of significant stenosis (≥50% lumen restriction) of F_0.5, 50-keV VMI+, and 60-keV VMI data sets were assessed. Objective image quality metrics were highest in the 40- and 50-keV VMI+ series (SNR: 20.2 ± 10.7 and 19.0 ± 9.5, respectively; CNR: 18.5 ± 10.3 and 16.8 ± 9.1, respectively) and were significantly (all P traditional VMI technique and standard linear blending for evaluation of the lower extremity runoff using dual-energy CTA.

  19. Aspects of pulmonary histiocytosis X on high resolution computed tomography; Aspectos da histiocitose X pulmonar na tomografia computadorizada de alta resolucao (TCAR)

    Energy Technology Data Exchange (ETDEWEB)

    Costa, N.S.S.; Castro Lessa Angela, M.T. de; Angelo Junior, J.R.L.; Silva, F.M.D.; Kavakama, J.; Carvalho, C.R.R. de; Cerri, G.G. [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Hospital das Clinicas. Inst. do Coracao

    1995-01-01

    Pulmonary histiocytosis X is a disease that occurs in young adults and presents with nodules and cysts, mainly in upper lobes, with consequent pulmonary fibrosis. These pulmonary changes are virtually pathognomonic findings on high resolution computed tomography, that allows estimate the area of the lung involved and distinguish histiocytosis X from other disorders that also produces nodules and cysts. (author). 10 refs, 2 tabs, 6 figs.

  20. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  1. Introducing Seismic Tomography with Computational Modeling

    Science.gov (United States)

    Neves, R.; Neves, M. L.; Teodoro, V.

    2011-12-01

    Learning seismic tomography principles and techniques involves advanced physical and computational knowledge. In depth learning of such computational skills is a difficult cognitive process that requires a strong background in physics, mathematics and computer programming. The corresponding learning environments and pedagogic methodologies should then involve sets of computational modelling activities with computer software systems which allow students the possibility to improve their mathematical or programming knowledge and simultaneously focus on the learning of seismic wave propagation and inverse theory. To reduce the level of cognitive opacity associated with mathematical or programming knowledge, several computer modelling systems have already been developed (Neves & Teodoro, 2010). Among such systems, Modellus is particularly well suited to achieve this goal because it is a domain general environment for explorative and expressive modelling with the following main advantages: 1) an easy and intuitive creation of mathematical models using just standard mathematical notation; 2) the simultaneous exploration of images, tables, graphs and object animations; 3) the attribution of mathematical properties expressed in the models to animated objects; and finally 4) the computation and display of mathematical quantities obtained from the analysis of images and graphs. Here we describe virtual simulations and educational exercises which enable students an easy grasp of the fundamental of seismic tomography. The simulations make the lecture more interactive and allow students the possibility to overcome their lack of advanced mathematical or programming knowledge and focus on the learning of seismological concepts and processes taking advantage of basic scientific computation methods and tools.

  2. Virtual Workshop

    DEFF Research Database (Denmark)

    Buus, Lillian; Bygholm, Ann

    In relation to the Tutor course in the Mediterranean Virtual University (MVU) project, a virtual workshop “Getting experiences with different synchronous communication media, collaboration, and group work” was held with all partner institutions in January 2006. More than 25 key-tutors within MVU...

  3. Tomography

    International Nuclear Information System (INIS)

    1985-01-01

    Already widely accepted in medicine, tomography can also be useful in industry. The theory behind tomography and a demonstration of the technique to inspect a motorcycle carburetor is presented. To demonstrate the potential of computer assisted tomography (CAT) to accurately locate defects in three dimensions, a sectioned 5 cm gate valve with a shrink cavity made visible by the sectioning was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +-1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  4. Creating Virtual-hand and Virtual-face Illusions to Investigate Self-representation.

    Science.gov (United States)

    Ma, Ke; Lippelt, Dominique P; Hommel, Bernhard

    2017-03-01

    Studies investigating how people represent themselves and their own body often use variants of "ownership illusions", such as the traditional rubber-hand illusion or the more recently discovered enfacement illusion. However, these examples require rather artificial experimental setups, in which the artificial effector needs to be stroked in synchrony with the participants' real hand or face-a situation in which participants have no control over the stroking or the movements of their real or artificial effector. Here, we describe a technique to establish ownership illusions in a setup that is more realistic, more intuitive, and of presumably higher ecological validity. It allows creating the virtual-hand illusion by having participants control the movements of a virtual hand presented on a screen or in virtual space in front of them. If the virtual hand moves in synchrony with the participants' own real hand, they tend to perceive the virtual hand as part of their own body. The technique also creates the virtual-face illusion by having participants control the movements of a virtual face in front of them, again with the effect that they tend to perceive the face as their own if it moves in synchrony with their real face. Studying the circumstances that illusions of this sort can be created, increased, or reduced provides important information about how people create and maintain representations of themselves.

  5. Radiological assessment of the placement of Essure® in order to reduce hysterosalpingography: Pelvic X-ray versus combined pelvic X-ray and ultrasound.

    Science.gov (United States)

    Petit, C; Vernet, T; Verpillat, P; Rubod, C; Cosson, M; Giraudet, G

    2017-10-01

    Three months after hysteroscopic sterilisation with Essure ® , a confirmation test is required to evaluate the correct location of the inserts. The test may be conducted using a pelvic ultrasound (2D or 3D) or an abdominal X-ray. Should the location not look satisfactory on these tests, a follow-up hysterosalpingography (HSG) would be required. The objective of our study is to assess whether the Essure ® 3-month confirmation test using a single X-ray or a combination of X-ray and ultrasound could reduce the use of HSG. This retrospective study examined patients who underwent birth control Essure ® procedure between 2009 and 2015 in the Gynaecological Surgery Department at the Regional University Hospital Centre (CHRU) in Lille. We divided patients into two groups based on the imaging tests performed: single X-ray (2009-2010) versus X-ray and pelvic ultrasound (2014-2015). We then compared the results of the imaging tests and the use of HSG between the two groups. One hundred and thirty-four patients were tested, of which 60 (44.8%) using a single X-ray and 74 (55.2%) using a combination of X-ray and ultrasound. We note that the combined X-ray/ultrasound test reduces significantly the number of HSG performed (26.7% versus 12.2%, P=0.04). Compared to a single X-ray, the combination of X-ray and ultrasound enables to significantly limit the use of HSG. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  6. Virtual data in CMS production

    International Nuclear Information System (INIS)

    Arbree, A. et al.

    2004-01-01

    Initial applications of the GriPhyN Chimera Virtual Data System have been performed within the context of CMS Production of Monte Carlo Simulated Data. The GriPhyN Chimera system consists of four primary components: (1) a Virtual Data Language, which is used to describe virtual data products, (2) a Virtual Data Catalog, which is used to store virtual data entries, (3) an Abstract Planner, which resolves all dependencies of a particular virtual data product and forms a location and existence independent plan, (4) a Concrete Planner, which maps an abstract, logical plan onto concrete, physical grid resources accounting for staging in/out files and publishing results to a replica location service. A CMS Workflow Planner, MCRunJob, is used to generate virtual data products using the Virtual Data Language. Subsequently, a prototype workflow manager, known as WorkRunner, is used to schedule the instantiation of virtual data products across a grid

  7. Virtual Data in CMS Production

    CERN Document Server

    Arbree, A; Bourilkov, D; Cavanaugh, R J; Graham, G; Katageri, S; Rodríguez, J; Voeckler, J; Wilde, M

    2003-01-01

    Initial applications of the GriPhyN Chimera Virtual Data System have been performed within the context of CMS Production of Monte Carlo Simulated Data. The GriPhyN Chimera system consists of four primary components: 1) a Virtual Data Language, which is used to describe virtual data products, 2) a Virtual Data Catalog, which is used to store virtual data entries, 3) an Abstract Planner, which resolves all dependencies of a particular virtual data product and forms a location and existence independent plan, 4) a Concrete Planner, which maps an abstract, logical plan onto concrete, physical grid resources accounting for staging in/out files and publishing results to a replica location service. A CMS Workflow Planner, MCRunJob, is used to generate virtual data products using the Virtual Data Language. Subsequently, a prototype workflow manager, known as WorkRunner, is used to schedule the instantiation of virtual data products across a grid.

  8. Virtual reality exposure therapy

    OpenAIRE

    Rothbaum, BO; Hodges, L; Kooper, R

    1997-01-01

    It has been proposed that virtual reality (VR) exposure may be an alternative to standard in vivo exposure. Virtual reality integrates real-time computer graphics, body tracking devices, visual displays, and other sensory input devices to immerse a participant in a computer- generated virtual environment. Virtual reality exposure is potentially an efficient and cost-effective treatment of anxiety disorders. VR exposure therapy reduced the fear of heights in the first control...

  9. Virtual data

    International Nuclear Information System (INIS)

    Bjorklund, E.

    1993-01-01

    In the 1970's, when computers were memory limited, operating system designers created the concept of ''virtual memory'' which gave users the ability to address more memory than physically existed. In the 1990s, many large control systems have the potential for becoming data limited. We propose that many of the principles behind virtual memory systems (working sets, locality, caching, and clustering) can also be applied to data-limited systems - creating, in effect, ''virtual data systems.'' At the Los Alamos National Laboratory's Clinton P. Anderson Meson Physics Facility (LAMPF), we have applied these principles to a moderately sized (10,000 data points) data acquisition and control system. To test the principles, we measured the system's performance during tune-up, production, and maintenance periods. In this paper, we present a general discussion of the principles of a virtual data system along with some discussion of our own implementation and the results of our performance measurements

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  11. Universidades virtuales: ¿aprendizaje real?

    OpenAIRE

    Valenzuela González, Jaime R.

    2015-01-01

    1. Introducción; 2. Modalidades educativas; 3. Concepto y características de las universidades virtuales; 4. Un modelo de universidad virtual; 5. Universidades virtuales ¿aprendizaje real?; 6. Tensiones de las universidades virtuales; 7. Referencias

  12. MULTIMEDIA EDITOR OF VIRTUAL PHYSICAL LABORATORY IN DISTANCE LEARNING SYSTEM «KHERSON VIRTUAL UNIVERSITY»

    Directory of Open Access Journals (Sweden)

    Kravtsov H.

    2017-12-01

    Full Text Available The questions of modeling the structure of the objects of the system, the design of software modules and technologies for creating the editor of a virtual laboratory are considered. The relevance of the study is due to the lack in existing distance learning systems of support for the creation and use of virtual laboratory work on disciplines of the natural-science profile. The subject of the study is a software module for creating and using virtual laboratory work in a distance learning system. The purpose of the study is the development of a system model and a description of the software development technology of a virtual laboratory for physics for a distance learning system. The information technologies of designing the structure of the virtual laboratory and the main modes of the program module of the editor of the virtual laboratory work are described. At the heart of the structure of the software module "Virtual Laboratory" is the multimedia Web-editor of virtual laboratory works, which is created using object-oriented design technology. The program library of multimedia 3D objects created in the development environment of interactive graphic objects Unity3D. It unifies the process of creation and processing of virtual laboratory works. The basic mathematical package for supporting calculations is the mathematical processor Waterloo Maple. The application of the developed software interface will allow teachers to create laboratory works and use them in their distance courses. Students, in turn, will be able to conduct research, performing virtual laboratory work. As an example, the editor of the virtual laboratory for physics in the distance learning system "Kherson Virtual University" is considered.

  13. Virtualized Networks and Virtualized Optical Line Terminal (vOLT)

    Science.gov (United States)

    Ma, Jonathan; Israel, Stephen

    2017-03-01

    The success of the Internet and the proliferation of the Internet of Things (IoT) devices is forcing telecommunications carriers to re-architecture a central office as a datacenter (CORD) so as to bring the datacenter economics and cloud agility to a central office (CO). The Open Network Operating System (ONOS) is the first open-source software-defined network (SDN) operating system which is capable of managing and controlling network, computing, and storage resources to support CORD infrastructure and network virtualization. The virtualized Optical Line Termination (vOLT) is one of the key components in such virtualized networks.

  14. A study on development of virtual panel and virtual collaboration system

    International Nuclear Information System (INIS)

    Yoo, H. J.; Park, S. Y.; Lee, M. S.; Hong, J. H.

    2001-01-01

    The Nuclear I and C group of KEPRI has been peforming research and development on the VRCATS, Virtual Reality based Computer Assisted Training System. For the past two years, we have developed the first VRCATS for Youngkwang 1 nuclear power plant. Currently, we are developing an advanced VRCATS for Uljin 3 nuclear power plant. In this paepr, we will describe virtual panel system and VR based collaborate training system (VRCATS) of the Uljin VRCATS. Since Virtual Panel provides the same environment as the real MCR, trainees can expect the same training effect with Virtual Panel as they do with full scope simulator. i.e., trainees can check key variables and operate the plants and get responses with Virtual Panel. VRCTS provides another realistic training environment for trainees. In VRCATS, for example, operators in a group can work together t handle LOCA (Loss of Coolant Accident) according to emergency operation procedures

  15. Virtual colonoscopy: clinical application

    International Nuclear Information System (INIS)

    Laghi, A.

    2005-01-01

    Virtual colonoscopy (VC), also known as computed tomography Colonography (CTC), is a non-invasive test for the examination of the colon based on volumetric, thin-collimation CT acquisition of a cleansed and air-distended colon. The technique is easy, less labour-intensive than barium enema and conventional colonoscopy, and is inherently safer. Several studies demonstrate the ability of VC in the detection of colonic neoplastic lesions, not only large carcinomas, but also polyps. Currently, the most widely accepted clinical indication is incomplete or unsuccessful colonoscopy, which may be the result of redundant colon, patient intolerance to the procedure, spasm not resolving even with the use of spasmolytics, obstructing colo-rectal cancer. VC is also used to detect cancer in frail and immobile patients to avoid sedation during colonoscopy or the turning required during barium enema. The use of VC in patients under surveillance following colo-rectal cancer surgery is under investigation. Further studies are necessary in order to assess the cost-effectiveness of this approach. For colo-rectal cancer screening, a practical approach is to consider VC as a currently credible alternative screening method and as a reasonable alternative to the other colo-rectal cancer screening tests when a patient is unable or unwilling to undergo conventional colonoscopy. (orig.)

  16. Virtual colonoscopy: clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Laghi, A. [Univ. of Rome La Sapienza, Polo Didattico Pontino, Latina (Italy)

    2005-11-15

    Virtual colonoscopy (VC), also known as computed tomography Colonography (CTC), is a non-invasive test for the examination of the colon based on volumetric, thin-collimation CT acquisition of a cleansed and air-distended colon. The technique is easy, less labour-intensive than barium enema and conventional colonoscopy, and is inherently safer. Several studies demonstrate the ability of VC in the detection of colonic neoplastic lesions, not only large carcinomas, but also polyps. Currently, the most widely accepted clinical indication is incomplete or unsuccessful colonoscopy, which may be the result of redundant colon, patient intolerance to the procedure, spasm not resolving even with the use of spasmolytics, obstructing colo-rectal cancer. VC is also used to detect cancer in frail and immobile patients to avoid sedation during colonoscopy or the turning required during barium enema. The use of VC in patients under surveillance following colo-rectal cancer surgery is under investigation. Further studies are necessary in order to assess the cost-effectiveness of this approach. For colo-rectal cancer screening, a practical approach is to consider VC as a currently credible alternative screening method and as a reasonable alternative to the other colo-rectal cancer screening tests when a patient is unable or unwilling to undergo conventional colonoscopy. (orig.)

  17. Using virtual machine monitors to overcome the challenges of monitoring and managing virtualized cloud infrastructures

    Science.gov (United States)

    Bamiah, Mervat Adib; Brohi, Sarfraz Nawaz; Chuprat, Suriayati

    2012-01-01

    Virtualization is one of the hottest research topics nowadays. Several academic researchers and developers from IT industry are designing approaches for solving security and manageability issues of Virtual Machines (VMs) residing on virtualized cloud infrastructures. Moving the application from a physical to a virtual platform increases the efficiency, flexibility and reduces management cost as well as effort. Cloud computing is adopting the paradigm of virtualization, using this technique, memory, CPU and computational power is provided to clients' VMs by utilizing the underlying physical hardware. Beside these advantages there are few challenges faced by adopting virtualization such as management of VMs and network traffic, unexpected additional cost and resource allocation. Virtual Machine Monitor (VMM) or hypervisor is the tool used by cloud providers to manage the VMs on cloud. There are several heterogeneous hypervisors provided by various vendors that include VMware, Hyper-V, Xen and Kernel Virtual Machine (KVM). Considering the challenge of VM management, this paper describes several techniques to monitor and manage virtualized cloud infrastructures.

  18. Organization Virtual or Networked?

    Directory of Open Access Journals (Sweden)

    Rūta Tamošiūnaitė

    2013-08-01

    Full Text Available Purpose—to present distinction between “virtual organization” and “networked organization”; giving their definitions.Design/methodology/approach—review of previous researches, systemic analyses of their findings and synthesis of distinctive characteristics of ”virtual organization” and “networked organization.”Findings—the main result of the research is key diverse features separating ”virtual organization” and ”networked organization.” Definitions of “virtual organization” and “networked organization” are presented.Originality/Value—distinction between “virtual organization” and “networked organization” creates possibilities to use all advantages of those types of organizations and gives foundation for deeper researches in this field.Research type: general review.

  19. Perception of Virtual Audiences.

    Science.gov (United States)

    Chollet, Mathieu; Scherer, Stefan

    2017-01-01

    A growing body of evidence shows that virtual audiences are a valuable tool in the treatment of social anxiety, and recent works show that it also a useful in public-speaking training programs. However, little research has focused on how such audiences are perceived and on how the behavior of virtual audiences can be manipulated to create various types of stimuli. The authors used a crowdsourcing methodology to create a virtual audience nonverbal behavior model and, with it, created a dataset of videos with virtual audiences containing varying behaviors. Using this dataset, they investigated how virtual audiences are perceived and which factors affect this perception.

  20. Virtual School Startups: Founder Processes in American K-12 Public Virtual Schools

    Science.gov (United States)

    Taylor, Brett D.; McNair, Delores E.

    2018-01-01

    Traditional school districts do not have a lot of experience with virtual schools and have lost students to state and charter virtual schools. To retain students and offer alternative learning opportunities, more public districts are starting their own virtual schools. This study was an examination of foundational processes at three California…

  1. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report.

    Science.gov (United States)

    Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2016-01-01

    Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis.

  2. Leader competencies in virtual organization

    OpenAIRE

    Bulinska-Stangrecka, Helena

    2018-01-01

    This paper discusses the competence required in the leadership of virtual organization. The specics of virtual organization presents a challenge to traditional managerial styles. In order to achieve success in virtual environment, a leader must develop specic abilities. This analysis examines the uniqueness of the virtual organization, including team work and management. The last part presents ndings and summaries regarding e€ective e-leadership requirement. A virtual leader ma...

  3. Virtual Reality: An Overview.

    Science.gov (United States)

    Franchi, Jorge

    1994-01-01

    Highlights of this overview of virtual reality include optics; interface devices; virtual worlds; potential applications, including medicine and archaeology; problems, including costs; current research and development; future possibilities; and a listing of vendors and suppliers of virtual reality products. (Contains 11 references.) (LRW)

  4. Virtual currencies- Real opportunities?

    OpenAIRE

    Selldahl, Sara

    2013-01-01

    The European Central Bank defines virtual currencies as ”unregulated, digital money, which is issued and usually controlled by its developers, and used and accepted among the members of a specific virtual community.” (European Central Bank, 2012, p. 5) The interest in virtual currencies has increased immensely over the last few years as they become increasingly prevalent in our society across many different industries. Up until now, the field of virtual currencies has been mainly uncharted ...

  5. Agreements in Virtual Organizations

    Science.gov (United States)

    Pankowska, Malgorzata

    This chapter is an attempt to explain the important impact that contract theory delivers with respect to the concept of virtual organization. The author believes that not enough research has been conducted in order to transfer theoretical foundations for networking to the phenomena of virtual organizations and open autonomic computing environment to ensure the controllability and management of them. The main research problem of this chapter is to explain the significance of agreements for virtual organizations governance. The first part of this chapter comprises explanations of differences among virtual machines and virtual organizations for further descriptions of the significance of the first ones to the development of the second. Next, the virtual organization development tendencies are presented and problems of IT governance in highly distributed organizational environment are discussed. The last part of this chapter covers analysis of contracts and agreements management for governance in open computing environments.

  6. In Vivo Diffuse Optical Tomography and Fluorescence Molecular Tomography

    Directory of Open Access Journals (Sweden)

    Mingze Li

    2010-01-01

    Full Text Available Diffuse optical tomography (DOT and fluorescence molecular tomography (FMT are two attractive imaging techniques for in vivo physiological and psychological research. They have distinct advantages such as non-invasiveness, non-ionizing radiation, high sensitivity and longitudinal monitoring. This paper reviews the key components of DOT and FMT. Light propagation model, mathematical reconstruction algorithm, imaging instrumentation and medical applications are included. Future challenges and perspective on optical tomography are discussed.

  7. Virtual Machine in Automation Projects

    OpenAIRE

    Xing, Xiaoyuan

    2010-01-01

    Virtual machine, as an engineering tool, has recently been introduced into automation projects in Tetra Pak Processing System AB. The goal of this paper is to examine how to better utilize virtual machine for the automation projects. This paper designs different project scenarios using virtual machine. It analyzes installability, performance and stability of virtual machine from the test results. Technical solutions concerning virtual machine are discussed such as the conversion with physical...

  8. Estimation of sex and age of ''virtual skeletons''-a feasibility study

    International Nuclear Information System (INIS)

    Grabherr, Silke; Cooper, Christine; Ulrich-Bochsler, Susi; Uldin, Tanya; Ross, Steffen; Oesterhelweg, Lars; Bolliger, Stephan; Thali, Michael J.; Christe, Andreas; Schnyder, Pierre; Mangin, Patrice

    2009-01-01

    This article presents a feasibility study with the objective of investigating the potential of multi-detector computed tomography (MDCT) to estimate the bone age and sex of deceased persons. To obtain virtual skeletons, the bodies of 22 deceased persons with known age at death were scanned by MDCT using a special protocol that consisted of high-resolution imaging of the skull, shoulder girdle (including the upper half of the humeri), the symphysis pubis and the upper halves of the femora. Bone and soft-tissue reconstructions were performed in two and three dimensions. The resulting data were investigated by three anthropologists with different professional experience. Sex was determined by investigating three-dimensional models of the skull and pelvis. As a basic orientation for the age estimation, the complex method according to Nemeskeri and co-workers was applied. The final estimation was effected using additional parameters like the state of dentition, degeneration of the spine, etc., which where chosen individually by the three observers according to their experience. The results of the study show that the estimation of sex and age is possible by the use of MDCT. Virtual skeletons present an ideal collection for anthropological studies, because they are obtained in a non-invasive way and can be investigated ad infinitum. (orig.)

  9. The Virtuality Continuum Revisited

    NARCIS (Netherlands)

    Nijholt, Antinus; Traum, D.; Zhai, Sh.; Kellogg, W.

    2005-01-01

    We survey the themes and the aims of a workshop devoted to the state-of-the-art virtuality continuum. In this continuum, ranging from fully virtual to real physical environments, allowing for mixed, augmented and desktop virtual reality, several perspectives can be taken. Originally, the emphasis

  10. The virtual nose: a 3-dimensional virtual reality model of the human nose.

    Science.gov (United States)

    Vartanian, A John; Holcomb, Joi; Ai, Zhuming; Rasmussen, Mary; Tardy, M Eugene; Thomas, J Regan

    2004-01-01

    The 3-dimensionally complex interplay of soft tissue, cartilaginous, and bony elements makes the mastery of nasal anatomy difficult. Conventional methods of learning nasal anatomy exist, but they often involve a steep learning curve. Computerized models and virtual reality applications have been used to facilitate teaching in a number of other complex anatomical regions, such as the human temporal bone and pelvic floor. We present a 3-dimensional (3-D) virtual reality model of the human nose. Human cadaveric axial cross-sectional (0.33-mm cuts) photographic data of the head and neck were used. With 460 digitized images, individual structures were traced and programmed to create a computerized polygonal model of the nose. Further refinements to this model were made using a number of specialized computer programs. This 3-D computer model of the nose was then programmed to operate as a virtual reality model. Anatomically correct 3-D model of the nose was produced. High-resolution images of the "virtual nose" demonstrate the nasal septum, lower lateral cartilages, middle vault, bony dorsum, and other structural details of the nose. Also, the model can be combined with a separate virtual reality model of the face and its skin cover as well as the skull. The user can manipulate the model in space, examine 3-D anatomical relationships, and fade superficial structures to reveal deeper ones. The virtual nose is a 3-D virtual reality model of the nose that is accurate and easy to use. It can be run on a personal computer or in a specialized virtual reality environment. It can serve as an effective teaching tool. As the first virtual reality model of the nose, it establishes a virtual reality platform from which future applications can be launched.

  11. Virtual Museums as Educational Tool

    DEFF Research Database (Denmark)

    2007-01-01

    Virtual Museums as Educational Tool On this web site you will find a collection of resources on virtual museums. The web site is meant to be a knowledge base for people with interest in museums, virtuality and education, and how virtual museums may contribute to adult education and lifelong...

  12. [Virtual reality in neurosurgery].

    Science.gov (United States)

    Tronnier, V M; Staubert, A; Bonsanto, M M; Wirtz, C R; Kunze, S

    2000-03-01

    Virtual reality enables users to immerse themselves in a virtual three-dimensional world and to interact in this world. The simulation is different from the kind in computer games, in which the viewer is active but acts in a nonrealistic world, or on the TV screen, where we are passively driven in an active world. In virtual reality elements look realistic, they change their characteristics and have almost real-world unpredictability. Virtual reality is not only implemented in gambling dens and the entertainment industry but also in manufacturing processes (cars, furniture etc.), military applications and medicine. Especially the last two areas are strongly correlated, because telemedicine or telesurgery was originated for military reasons to operate on war victims from a secure distance or to perform surgery on astronauts in an orbiting space station. In medicine and especially neurosurgery virtual-reality methods are used for education, surgical planning and simulation on a virtual patient.

  13. Geometric morphometric methods for three-dimensional virtual reconstruction of a fragmented cranium: the case of Angelo Poliziano.

    Science.gov (United States)

    Benazzi, S; Stansfield, E; Milani, C; Gruppioni, G

    2009-07-01

    The process of forensic identification of missing individuals is frequently reliant on the superimposition of cranial remains onto an individual's picture and/or facial reconstruction. In the latter, the integrity of the skull or a cranium is an important factor in successful identification. Here, we recommend the usage of computerized virtual reconstruction and geometric morphometrics for the purposes of individual reconstruction and identification in forensics. We apply these methods to reconstruct a complete cranium from facial remains that allegedly belong to the famous Italian humanist of the fifteenth century, Angelo Poliziano (1454-1494). Raw data was obtained by computed tomography scans of the Poliziano face and a complete reference skull of a 37-year-old Italian male. Given that the amount of distortion of the facial remains is unknown, two reconstructions are proposed: The first calculates the average shape between the original and its reflection, and the second discards the less preserved left side of the cranium under the assumption that there is no deformation on the right. Both reconstructions perform well in the superimposition with the original preserved facial surface in a virtual environment. The reconstruction by means of averaging between the original and reflection yielded better results during the superimposition with portraits of Poliziano. We argue that the combination of computerized virtual reconstruction and geometric morphometric methods offers a number of advantages over traditional plastic reconstruction, among which are speed, reproducibility, easiness of manipulation when superimposing with pictures in virtual environment, and assumptions control.

  14. Study on virtual instrument developing system based on intelligent virtual control

    International Nuclear Information System (INIS)

    Tang Baoping; Cheng Fabin; Qin Shuren

    2005-01-01

    The paper introduces a non-programming developing system of a virtual instrument (VI), i.e., a virtual measurement instrument developing system (VMIDS) based on intelligent virtual control (IVC). The background of the IVC-based VMIDS is described briefly, and the hierarchical message bus (HMB)-based software architecture of VMIDS is discussed in detail. The three parts and functions of VMIDS are introduced, and the process of non-programming developing VI is further described

  15. Study on virtual instrument developing system based on intelligent virtual control

    Energy Technology Data Exchange (ETDEWEB)

    Tang Baoping; Cheng Fabin; Qin Shuren [Test Center, College of Mechanical Engineering, Chongqing University , Chongqing 400030 (China)

    2005-01-01

    The paper introduces a non-programming developing system of a virtual instrument (VI), i.e., a virtual measurement instrument developing system (VMIDS) based on intelligent virtual control (IVC). The background of the IVC-based VMIDS is described briefly, and the hierarchical message bus (HMB)-based software architecture of VMIDS is discussed in detail. The three parts and functions of VMIDS are introduced, and the process of non-programming developing VI is further described.

  16. Virtual Reality Design: How Head-Mounted Displays Change Design Paradigms of Virtual Reality Worlds

    Directory of Open Access Journals (Sweden)

    Christian Stein

    2016-09-01

    Full Text Available With the upcoming generation of virtual reality HMDs, new virtual worlds, scenarios, and games are created especially for them. These are no longer bound to a remote screen or a relatively static user, but to an HMD as a more immersive device. This article discusses requirements for virtual scenarios implemented in new-generation HMDs to achieve a comfortable user experience. Furthermore, the effects of positional tracking are introduced and the relation between the user’s virtual and physical body is analyzed. The observations made are exemplified by existing software prototypes. They indicate how the term “virtual reality,” with all its loaded connotations, may be reconceptualized to express the peculiarities of HMDs in the context of gaming, entertainment, and virtual experiences.

  17. Virtualization Technologies for the Business

    OpenAIRE

    Sabina POPESCU

    2011-01-01

    There is a new trend of change in today's IT industry. It's called virtualization. In datacenter virtualization can occur on several levels, but the type of virtualization has created this trend change is the operating system offered or server virtualization. OS virtualization technologies come in two forms. First, there is a software component that is used to simulate a natural machine that has total control of an operating system operating on the host equipment. The second is a hypervisor, ...

  18. Sobre objetos y experiencias virtuales

    OpenAIRE

    Pacho, Julián

    2009-01-01

    This paper analyses basic onto-epistemological properties of the virtual reality and suggests these theses. First, the virtual reality establishes a new nature; its essential feature is to be an organic world of emancipated techno-theories. Second, the virtual reality doesn’t substitutes the traditional book; it substitutes the world. Third, the experience of the world in the virtual reality excludes the natural world experience. Fourth, the ontology of virtual reality is build without an act...

  19. Etnografía virtual Virtual ethnography: exploring a methodological option for the research on virtual learning environments.

    Directory of Open Access Journals (Sweden)

    Álvarez Cadavid Gloria María

    2009-01-01

    Full Text Available Este artículo pretende esbozar algunas de las consideraciones metodológicas que hoy confluyen en el estudio de los ambientes virtuales, desde la opción etnográfica. De manera específica se quiere observar la forma en que, algunos investigadores han abordado el aspecto metodológico para estudiar los ambientes virtuales, líneas de evolución y posible contribución al conocimiento y mejoramiento de los procesos de e-learning. This article aims to outline some methodological considerations that merge together on the study of virtual learning environments, especially from the ethnographic perspective. Specifically, what we want to observe, is the way some researchers have approached the methodological aspect in order to study virtual learning environments, the evolution lines and the possible contribution they’ve made to knowledge and improvement of e-learning processes.

  20. [Fabrication and accuracy research on 3D printing dental model based on cone beam computed tomography digital modeling].

    Science.gov (United States)

    Zhang, Hui-Rong; Yin, Le-Feng; Liu, Yan-Li; Yan, Li-Yi; Wang, Ning; Liu, Gang; An, Xiao-Li; Liu, Bin

    2018-04-01

    The aim of this study is to build a digital dental model with cone beam computed tomography (CBCT), to fabricate a virtual model via 3D printing, and to determine the accuracy of 3D printing dental model by comparing the result with a traditional dental cast. CBCT of orthodontic patients was obtained to build a digital dental model by using Mimics 10.01 and Geomagic studio software. The 3D virtual models were fabricated via fused deposition modeling technique (FDM). The 3D virtual models were compared with the traditional cast models by using a Vernier caliper. The measurements used for comparison included the width of each tooth, the length and width of the maxillary and mandibular arches, and the length of the posterior dental crest. 3D printing models had higher accuracy compared with the traditional cast models. The results of the paired t-test of all data showed that no statistically significant difference was observed between the two groups (P>0.05). Dental digital models built with CBCT realize the digital storage of patients' dental condition. The virtual dental model fabricated via 3D printing avoids traditional impression and simplifies the clinical examination process. The 3D printing dental models produced via FDM show a high degree of accuracy. Thus, these models are appropriate for clinical practice.

  1. Photon virtual bound state

    International Nuclear Information System (INIS)

    Inoue, J.; Ohtaka, K.

    2004-01-01

    We study virtual bound states in photonics, which are a vectorial extension of electron virtual bound states. The condition for these states is derived. It is found that the Mie resonant state which satisfies the condition that the size parameter is less than the angular momentum should be interpreted as a photon virtual bound state. In order to confirm the validity of the concept, we compare the photonic density of states, the width of which represents the lifetime of the photon virtual bound states, with numerical results

  2. [Research on the virtual water composition and virtual water trade for agriculture in Beijing].

    Science.gov (United States)

    Wang, Hong-rui; Wang, Yan; Wang, Jun-hong; Dong, Yan-yan; Han, Zhao-xing

    2007-12-01

    Based on the irrigation norm of typical district and county, and revised by the isoline map of Chinese crops water demand, the change of crops program was analyzed as well as the agricultural water use and its GDP benefits. Then the virtual water was calculated for years. At last, the input-output method was used to calculate the trade of virtual water in Beijing. As the results, the virtual water for cereal crops has been decreasing in Beijing, from 1.832 x 10(9) m3 in 1990 to 4.283 x 10(8) m3 in 2004. Otherwise the virtual water for technical crops has been increasing, which is from 9.06 x 10(8) m3 in 1990 to 1.492 x 10(9) m3 in 2004. On the whole, the virtual water for crops has been decreasing in Beijing. From the angle of primary products Beijing is a virtual water importing area. Virtual water importing of annual average is 2.37 x 10(8) m3, which is about 5.93% of the total water of Beijing. Virtual water has been an important supplement of local real water of Beijing.

  3. Eikonal Tomography of the Southern California Plate Boundary Region

    Science.gov (United States)

    Qiu, H.; Ben-Zion, Y.; Zigone, D.; Lin, F. C.

    2016-12-01

    We use eikonal tomography to derive directionally-dependent phase velocities of surface waves for the plate boundary region in southern CA sensitive to the approximate depth range 1-20 km. Seismic noise data recorded by 346 stations in the area provide a spatial coverage with 5-25 km typical station spacing and period range of 1-20 s. Noise cross-correlations are calculated for vertical component data recorded in year 2014. Rayleigh wave group and phase travel times between 2 and 13 sec period are derived for each station pair using frequency-time analysis. For each common station, all available phase travel time measurements with sufficient signal to noise ratio and envelope peak amplitude are used to construct a travel time map for a virtual source at the common station location. By solving the eikonal equation, both phase velocity and propagation direction are evaluated at each location for each virtual source. Isotropic phase velocities and 2-psi azimuthal anisotropy and their uncertainties are determined statistically using measurements from different virtual sources. Following the method of Barmin et al. (2001), group velocities are also inverted using all the group travel times that pass quality criteria. The obtained group and phase dispersions of Rayleigh waves are then inverted on a 6 x 6 km2 grid for local 1D piecewise shear wave velocity structures using the procedure of Herrmann (2013). The results agree well with previous observations of Zigone et al. (2015) in the overlapping area. Clear velocity contrasts and low velocity zones are seen for the San Andreas, San Jacinto, Elsinore and Garlock faults. We also find 2-psi azimuthal anisotropy with fast directions parallel to geometrically-simple fault sections. Details and updated results will be presented in the meeting.

  4. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  5. Art in virtual reality 2010

    Science.gov (United States)

    Chang, Ben

    2010-01-01

    For decades, virtual reality artwork has existed in a small but highly influential niche in the world of electronic and new media art. Since the early 1990's, virtual reality installations have come to define an extreme boundary point of both aesthetic experience and technological sophistication. Classic virtual reality artworks have an almost mythological stature - powerful, exotic, and often rarely exhibited. Today, art in virtual environments continues to evolve and mature, encompassing everything from fully immersive CAVE experiences to performance art in Second Life to the use of augmented and mixed reality in public space. Art in Virtual Reality 2010 is a public exhibition of new artwork that showcases the diverse ways that contemporary artists use virtual environments to explore new aesthetic ground and investigate the continually evolving relationship between our selves and our virtual worlds.

  6. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  7. Virtual autopsy with multiphase postmortem computed tomographic angiography versus traditional medical autopsy to investigate unexpected deaths of hospitalized patients: a cohort study.

    Science.gov (United States)

    Wichmann, Dominic; Heinemann, Axel; Weinberg, Clemens; Vogel, Hermann; Hoepker, Wilhelm Wolfgang; Grabherr, Silke; Pueschel, Klaus; Kluge, Stefan

    2014-04-15

    "Virtual" autopsy by postmortem computed tomography (PMCT) can replace medical autopsy to a certain extent but has limitations for cardiovascular diseases. These limitations might be overcome by adding multiphase PMCT angiography. To compare virtual autopsy by multiphase PMCT angiography with medical autopsy. Prospective cohort study. (ClinicalTrials.gov: NCT01541995) SETTING: Single-center study at the University Medical Center Hamburg-Eppendorf, Hamburg, Germany, between 1 April 2012 and 31 March 2013. Hospitalized patients who died unexpectedly or within 48 hours of an event necessitating cardiopulmonary resuscitation. Diagnoses from clinical records were compared with findings from both types of autopsy. New diagnoses identified by autopsy were classified as major or minor, depending on whether they would have altered clinical management. Of 143 eligible patients, 50 (35%) had virtual and medical autopsy. Virtual autopsy confirmed 93% of all 336 diagnoses identified from antemortem medical records, and medical autopsy confirmed 80%. In addition, virtual and medical autopsy identified 16 new major and 238 new minor diagnoses. Seventy-three of the virtual autopsy diagnoses, including 32 cases of coronary artery stenosis, were identified solely by multiphase PMCT angiography. Of the 114 clinical diagnoses classified as cardiovascular, 110 were confirmed by virtual autopsy and 107 by medical autopsy. In 11 cases, multiphase PMCT angiography showed "unspecific filling defects," which were not reported by medical autopsy. These results come from a single center with concerted interest and expertise in postmortem imaging; further studies are thus needed for generalization. In cases of unexpected death, the addition of multiphase PMCT angiography increases the value of virtual autopsy, making it a feasible alternative for quality control and identification of diagnoses traditionally made by medical autopsy. University Medical Center Hamburg-Eppendorf.

  8. Setting up virtual private network

    International Nuclear Information System (INIS)

    Huang Hongmei; Zhang Chengjun

    2003-01-01

    Setting up virtual private network for business enterprise provides a low cost network foundation, increases enterprise's network function and enlarges its private scope. The text introduces virtual private network's principal, privileges and protocols that use in virtual private network. At last, this paper introduces several setting up virtual private network's technologies which based on LAN

  9. Setting up virtual private network

    International Nuclear Information System (INIS)

    Huang Hongmei; Zhang Chengjun

    2003-01-01

    Setting up virtual private network for business enterprise provides a low cost network foundation, increases enterprise network function and enlarges its private scope. This text introduces virtual private network principal, privileges and protocols applied in virtual private network. At last, this paper introduces several setting up virtual private network technologies which is based on LAN

  10. Virtuality and Reality in Science

    International Nuclear Information System (INIS)

    Cohen-Tannoudji, G.

    1995-01-01

    This book compiles eight contributions devoted to the topical question about the relation between virtuality and reality. In the theoretical frame of quantum and relativistic particle physics, the concept of virtuality is used according to its strict and precise meaning. In this context, particles are generally invented before their discovery. Some famous historical experiments which led to the postulation and then the discovery of new particles are mentioned. These examples are used to illustrate and to discuss the concept of virtuality as well as the physical reality of virtual processes. But, how can the concept of virtuality in other scientific fields be applied ? In order to answer this question, the concepts of virtuality and reality are discussed in other branches of physics as well as in other fields such as geophysics, cosmology and biology. Philosophical and sociological implications of virtual realities are also considered. Moreover, in relation to virtuality and reality, the connections between modeling, simulation and experimentation, their respective roles, the advantages and risks of their use are discussed (in relation to nuclear sciences and geophysical problems) (N.T.)

  11. Optimizing Virtual Network Functions Placement in Virtual Data Center Infrastructure Using Machine Learning

    Science.gov (United States)

    Bolodurina, I. P.; Parfenov, D. I.

    2018-01-01

    We have elaborated a neural network model of virtual network flow identification based on the statistical properties of flows circulating in the network of the data center and characteristics that describe the content of packets transmitted through network objects. This enabled us to establish the optimal set of attributes to identify virtual network functions. We have established an algorithm for optimizing the placement of virtual data functions using the data obtained in our research. Our approach uses a hybrid method of visualization using virtual machines and containers, which enables to reduce the infrastructure load and the response time in the network of the virtual data center. The algorithmic solution is based on neural networks, which enables to scale it at any number of the network function copies.

  12. Incorporating Virtually Immersive Environments as a Collaborative Medium for Virtual Teaming

    Directory of Open Access Journals (Sweden)

    Charles J. Lesko, Jr.

    2012-08-01

    Full Text Available Virtually immersive environments incorporate the use of various computer modelling and simulation techniques enabling geographically dispersed virtual project teams to interact within an artificially projected three-dimensional space online. This study focused on adoption of virtually immersive technologies as a collaborative media to support virtual teaming of both graduate and undergraduate-level project management students. The data and information from this study has implications for educators using virtually immersive environments in the classroom. In this study, we specifically evaluated two key components in this paper: 1 students’ level of trust and; 2 students’ willingness to use the technology, along with their belief about the virtual environment’s ability to extend and improve knowledge sharing in their team work environment. We learned that while students did find the environment a positive add on for working collaboratively, there were students who were neither more nor less likely to use the technology for future collaborative ventures. Most of the students who were not very positive about the environment were “fence sitters” likely indicating needs related to additional training to improve communication skills. Finally, based on the full study results we have provided basic recommendations designed to support team trust building in the system along with interpersonal trust building to facilitate knowledge transfer and better strategic us of the technology.

  13. Virtual cystoscopy, computed tomography urography and optical cystoscopy for the detection and follow-up for bladder cancer.

    Science.gov (United States)

    Ibáñez Muñoz, D; Quintana Martínez, I; Fernández Militino, A; Sánchez Zalabardo, D; Sarria Octavio de Toledo, L; Cozcolluela Cabrejas, R

    To evaluate the utility of virtual cystoscopy (VC) performed with CT urography in patients being studied under gross hematuria or patients being followed-up after a previous bladder cancer and compare the results with those obtained with gold standard technique (optical cystoscopy). Retrospective study of 117 patients who were referred for VC by the Urology Department between May 2014 and May 2015. Those patients presented with gross hematuria or they were previously treated patients from bladder cancer being followed up. These patients were evaluated with MDCT and virtual cystoscopy after distending the bladder with air. The results were compared with those obtained with optical cystoscopy which was performed no more than a week after. The global sensitivity and specificity of VC were 81,8 and 92,1%. Aditional findings detected in CT urography were an aortic dissection, urinary lithiasis and colonic metastasis. VC seems an useful technique in the diagnosis and follow-up for bladder cancer with a good correlation with OC. The main limitations are the impossibility of biopsy during the procedure and the detection of erythematous lesions. Collateral findings can be detected performed with CT urography although the high radiation exposure does not recommend their combined use. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Virtual Teaming and Collaboration Technology: A Study of Influences on Virtual Project Outcomes

    Science.gov (United States)

    Broils, Gary C.

    2014-01-01

    The purpose of this quantitative correlational study was to explore the relationships between the independent variables, contextual factors for virtual teams and collaboration technology, and the dependent variable, virtual project outcomes. The problem leading to the need for the study is a lower success rate for virtual projects compared to…

  15. The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in resectable pancreatic cancer.

    Science.gov (United States)

    Crippa, Stefano; Salgarello, Matteo; Laiti, Silvia; Partelli, Stefano; Castelli, Paola; Spinelli, Antonello E; Tamburrino, Domenico; Zamboni, Giuseppe; Falconi, Massimo

    2014-08-01

    The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in pancreatic ductal adenocarcinoma is debated. We retrospectively assessed the value of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in addition to conventional imaging as a staging modality in pancreatic cancer. (18)Fluoro-deoxyglucose positron emission tomography/computed tomography was performed in 72 patients with resectable pancreatic carcinoma after multi-detector computed tomography positron emission tomography was considered positive for a maximum standardized uptake value >3. Overall, 21% of patients had a maximum standardized uptake value ≤ 3, and 60% of those had undergone neoadjuvant treatment (P=0.0001). Furthermore, 11% of patients were spared unwarranted surgery since positron emission tomography/computed tomography detected metastatic disease. All liver metastases were subsequently identified with contrast-enhanced ultrasound. Sensitivity and specificity of positron emission tomography/computed tomography for distant metastases were 78% and 100%. The median CA19.9 concentration was 48.8 U/mL for the entire cohort and 292 U/mL for metastatic patients (P=0.112). The widespread application of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in patients with resectable pancreatic carcinoma seems not justified. It should be considered in selected patients at higher risk of metastatic disease (i.e. CA19.9>200 U/mL) after undergoing other imaging tests. Neoadjuvant treatment is significantly associated with low metabolic activity, limiting the value of positron emission tomography in this setting. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  16. The potential of dual-energy virtual monochromatic imaging in reducing renal cyst pseudoenhancement. A phantom study

    International Nuclear Information System (INIS)

    Yamada, Sachiko; Ueguchi, Takashi; Ukai, Isao; Nagai, Yumiko; Yamakawa, Masanobu; Shimosegawa, Eku; Shimazu, Takeshi; Hatazawa, Jun

    2012-01-01

    Renal cyst pseudoenhancement, an artifactual increase of computed tomography (CT) attenuation for cysts with increased iodine concentrations in the renal parenchyma, complicates the classification of cysts and may thus lead to the mischaracterization of a benign non-enhancing lesion as an enhancing mass. The purpose of this study was to use a phantom model to assess the ability of dual-energy virtual monochromatic imaging to reduce renal pseudoenhancement. A water-filled cylindrical cyst model suspended in varying concentrations of iodine solution, to simulate varying levels of parenchymal enhancement, was scanned with a dual-energy CT scanner using the following three scanning protocols with different combinations of tube voltage: 80 and 140 kV; 80 and 140 kV with tin filter; and 100 and 140 kV with tin filter. Virtual monochromatic images were then synthesized for each dual-energy scan. Single-energy scan with a tube voltage of 120 kV was also performed to obtain polychromatic images as controls. Mean attenuation values (in Hounsfield units) of cyst proxies were measured on both polychromatic and virtual monochromatic images. Pseudoenhancement was considered to be present when the cyst attenuation level increased by more than 10 HU (Hounsfield Unit) as the background iodine concentration increased from 0.0% to 0.4%, 1.5%, or 2.5%. Our results revealed that pseudoenhancement was not observed on any of the monochromatic images, but appeared on polychromatic images at a background iodine concentration of 2.5%. We thus conclude that dual-energy virtual monochromatic images have a potential to reduce renal pseudoenhancement. (author)

  17. Interpretations of virtual reality.

    Science.gov (United States)

    Voiskounsky, Alexander

    2011-01-01

    University students were surveyed to learn what they know about virtual realities. The two studies were administered with a half-year interval in which the students (N=90, specializing either in mathematics and science, or in social science and humanities) were asked to name particular examples of virtual realities. The second, but not the first study, was administered after the participants had the chance to see the movie "Avatar" (no investigation was held into whether they really saw it). While the students in both studies widely believed that activities such as social networking and online gaming represent virtual realities, some other examples provided by the students in the two studies differ: in the second study the participants expressed a better understanding of the items related to virtual realities. At the same time, not a single participant reported particular psychological states (either regular or altered) as examples of virtual realities. Profound popularization efforts need to be done to acquaint the public, including college students, with virtual realities and let the public adequately understand how such systems work.

  18. Using virtual ridge augmentation and 3D printing to fabricate a titanium mesh positioning device: A novel technique letter.

    Science.gov (United States)

    Al-Ardah, Aladdin; Alqahtani, Nasser; AlHelal, Abdulaziz; Goodacre, Brian; Swamidass, Rajesh; Garbacea, Antoanela; Lozada, Jaime

    2018-05-02

    This technique describes a novel approach for planning and augmenting a large bony defect using a titanium mesh (TiMe). A 3-dimensional (3D) surgical model was virtually created from a cone beam computed tomography (CBCT) and wax-pattern of the final prosthetic outcome. The required bone volume (horizontally and vertically) was digitally augmented and then 3D printed to create a bone model. The 3D model was then used to contour the TiMe in accordance with the digital augmentation. With the contoured / preformed TiMe on the 3D printed model a positioning jig was made to aid the placement of the TiMe as planned during surgery. Although this technique does not impact the final outcome of the augmentation procedure, it allows the clinician to virtually design the augmentation, preform and contour the TiMe, and create a positioning jig reducing surgical time and error.

  19. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  20. Virtual Dance and Motion-Capture

    Directory of Open Access Journals (Sweden)

    Marc Boucher

    2011-01-01

    Full Text Available A general view of various ways in which virtual dance can be understood is presented in the first part of this article. It then appraises the uses of the term “virtual” in previous studies of digital dance. A more in-depth view of virtual dance as it relates to motion-capture is offered, and key issues are discussed regarding computer animation, digital imaging, motion signature, virtual reality and interactivity. The paper proposes that some forms of virtual dance be defined in relation to both digital technologies and contemporary theories of virtuality.

  1. Sense of presence and anxiety during virtual social interactions between a human and virtual humans.

    Science.gov (United States)

    Morina, Nexhmedin; Brinkman, Willem-Paul; Hartanto, Dwi; Emmelkamp, Paul M G

    2014-01-01

    Virtual reality exposure therapy (VRET) has been shown to be effective in treatment of anxiety disorders. Yet, there is lack of research on the extent to which interaction between the individual and virtual humans can be successfully implanted to increase levels of anxiety for therapeutic purposes. This proof-of-concept pilot study aimed at examining levels of the sense of presence and anxiety during exposure to virtual environments involving social interaction with virtual humans and using different virtual reality displays. A non-clinical sample of 38 participants was randomly assigned to either a head-mounted display (HMD) with motion tracker and sterescopic view condition or a one-screen projection-based virtual reality display condition. Participants in both conditions engaged in free speech dialogues with virtual humans controlled by research assistants. It was hypothesized that exposure to virtual social interactions will elicit moderate levels of sense of presence and anxiety in both groups. Further it was expected that participants in the HMD condition will report higher scores of sense of presence and anxiety than participants in the one-screen projection-based display condition. Results revealed that in both conditions virtual social interactions were associated with moderate levels of sense of presence and anxiety. Additionally, participants in the HMD condition reported significantly higher levels of presence than those in the one-screen projection-based display condition (p = .001). However, contrary to the expectations neither the average level of anxiety nor the highest level of anxiety during exposure to social virtual environments differed between the groups (p = .97 and p = .75, respectively). The findings suggest that virtual social interactions can be successfully applied in VRET to enhance sense of presence and anxiety. Furthermore, our results indicate that one-screen projection-based displays can successfully activate levels of anxiety in

  2. Sense of presence and anxiety during virtual social interactions between a human and virtual humans

    Directory of Open Access Journals (Sweden)

    Nexhmedin Morina

    2014-04-01

    Full Text Available Virtual reality exposure therapy (VRET has been shown to be effective in treatment of anxiety disorders. Yet, there is lack of research on the extent to which interaction between the individual and virtual humans can be successfully implanted to increase levels of anxiety for therapeutic purposes. This proof-of-concept pilot study aimed at examining levels of the sense of presence and anxiety during exposure to virtual environments involving social interaction with virtual humans and using different virtual reality displays. A non-clinical sample of 38 participants was randomly assigned to either a head-mounted display (HMD with motion tracker and sterescopic view condition or a one-screen projection-based virtual reality display condition. Participants in both conditions engaged in free speech dialogues with virtual humans controlled by research assistants. It was hypothesized that exposure to virtual social interactions will elicit moderate levels of sense of presence and anxiety in both groups. Further it was expected that participants in the HMD condition will report higher scores of sense of presence and anxiety than participants in the one-screen projection-based display condition. Results revealed that in both conditions virtual social interactions were associated with moderate levels of sense of presence and anxiety. Additionally, participants in the HMD condition reported significantly higher levels of presence than those in the one-screen projection-based display condition (p = .001. However, contrary to the expectations neither the average level of anxiety nor the highest level of anxiety during exposure to social virtual environments differed between the groups (p = .97 and p = .75, respectively. The findings suggest that virtual social interactions can be successfully applied in VRET to enhance sense of presence and anxiety. Furthermore, our results indicate that one-screen projection-based displays can successfully activate levels

  3. Innovation and Virtual Environments: Towards Virtual Knowledge Brokers

    OpenAIRE

    VERONA G; PRANDELLI E.; SAWHNEY M.

    2006-01-01

    The authors examine the implications of virtual customer environments for supporting the innovation process. By building on the literature of knowledge brokers, they introduce the concept of virtual knowledge brokers — actors who leverage the internet to support third parties’ innovation activities. These actors enable firms to extend their reach in engaging with customers and they also allow firms to have a richer dialogue with customers because of their perceived neutrality. Consequently...

  4. 3D virtual planning in orthognathic surgery and CAD/CAM surgical splints generation in one patient with craniofacial microsomia: a case report

    Science.gov (United States)

    Vale, Francisco; Scherzberg, Jessica; Cavaleiro, João; Sanz, David; Caramelo, Francisco; Maló, Luísa; Marcelino, João Pedro

    2016-01-01

    Objective: In this case report, the feasibility and precision of tridimensional (3D) virtual planning in one patient with craniofacial microsomia is tested using Nemoceph 3D-OS software (Software Nemotec SL, Madrid, Spain) to predict postoperative outcomes on hard tissue and produce CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) surgical splints. Methods: The clinical protocol consists of 3D data acquisition of the craniofacial complex by cone-beam computed tomography (CBCT) and surface scanning of the plaster dental casts. The ''virtual patient'' created underwent virtual surgery and a simulation of postoperative results on hard tissues. Surgical splints were manufactured using CAD/CAM technology in order to transfer the virtual surgical plan to the operating room. Intraoperatively, both CAD/CAM and conventional surgical splints are comparable. A second set of 3D images was obtained after surgery to acquire linear measurements and compare them with measurements obtained when predicting postoperative results virtually. Results: It was found a high similarity between both types of surgical splints with equal fitting on the dental arches. The linear measurements presented some discrepancies between the actual surgical outcomes and the predicted results from the 3D virtual simulation, but caution must be taken in the analysis of these results due to several variables. Conclusions: The reported case confirms the clinical feasibility of the described computer-assisted orthognathic surgical protocol. Further progress in the development of technologies for 3D image acquisition and improvements on software programs to simulate postoperative changes on soft tissue are required. PMID:27007767

  5. Virtual Pediatric Hospital

    Science.gov (United States)

    ... Thoracopaedia - An Imaging Encyclopedia of Pediatric Thoracic Disease Virtual Pediatric Hospital is the Apprentice's Assistant™ Last revised ... pediatric resources: GeneralPediatrics.com | PediatricEducation.org | SearchingPediatrics.com Virtual Pediatric Hospital is curated by Donna M. D' ...

  6. Uterus models for use in virtual reality hysteroscopy simulators.

    Science.gov (United States)

    Niederer, Peter; Weiss, Stephan; Caduff, Rosmarie; Bajka, Michael; Szekély, Gabor; Harders, Matthias

    2009-05-01

    Virtual reality models of human organs are needed in surgery simulators which are developed for educational and training purposes. A simulation can only be useful, however, if the mechanical performance of the system in terms of force-feedback for the user as well as the visual representation is realistic. We therefore aim at developing a mechanical computer model of the organ in question which yields realistic force-deformation behavior under virtual instrument-tissue interactions and which, in particular, runs in real time. The modeling of the human uterus is described as it is to be implemented in a simulator for minimally invasive gynecological procedures. To this end, anatomical information which was obtained from specially designed computed tomography and magnetic resonance imaging procedures as well as constitutive tissue properties recorded from mechanical testing were used. In order to achieve real-time performance, the combination of mechanically realistic numerical uterus models of various levels of complexity with a statistical deformation approach is suggested. In view of mechanical accuracy of such models, anatomical characteristics including the fiber architecture along with the mechanical deformation properties are outlined. In addition, an approach to make this numerical representation potentially usable in an interactive simulation is discussed. The numerical simulation of hydrometra is shown in this communication. The results were validated experimentally. In order to meet the real-time requirements and to accommodate the large biological variability associated with the uterus, a statistical modeling approach is demonstrated to be useful.

  7. Virtual Project Teams

    DEFF Research Database (Denmark)

    Bjørn, Pernille

    technology in six real-life virtual teams, two in industry and four in education, applying interpretative research and action research methods. Two main lines of investigation are pursued: the first involves an examination of the organisational issues related to groupware adaptation in virtual project teams......, professional disciplines, time differences and technology. This thesis comprises a general introduction, referred to as the summary report, and seven research papers, which deal in detail with the results and findings of the empirical cases. The summary report provides a general introduction to the research......, while the second looks at the social context and practices of virtual project teams. Two of the key findings are 1) that the process of groupware adaptation by virtual project teams can be viewed as a process of expanding and aligning the technological frames of the participants, which includes mutual...

  8. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  9. [Hybrid 3-D rendering of the thorax and surface-based virtual bronchoscopy in surgical and interventional therapy control].

    Science.gov (United States)

    Seemann, M D; Gebicke, K; Luboldt, W; Albes, J M; Vollmar, J; Schäfer, J F; Beinert, T; Englmeier, K H; Bitzer, M; Claussen, C D

    2001-07-01

    The aim of this study was to demonstrate the possibilities of a hybrid rendering method, the combination of a color-coded surface and volume rendering method, with the feasibility of performing surface-based virtual endoscopy with different representation models in the operative and interventional therapy control of the chest. In 6 consecutive patients with partial lung resection (n = 2) and lung transplantation (n = 4) a thin-section spiral computed tomography of the chest was performed. The tracheobronchial system and the introduced metallic stents were visualized using a color-coded surface rendering method. The remaining thoracic structures were visualized using a volume rendering method. For virtual bronchoscopy, the tracheobronchial system was visualized using a triangle surface model, a shaded-surface model and a transparent shaded-surface model. The hybrid 3D visualization uses the advantages of both the color-coded surface and volume rendering methods and facilitates a clear representation of the tracheobronchial system and the complex topographical relationship of morphological and pathological changes without loss of diagnostic information. Performing virtual bronchoscopy with the transparent shaded-surface model facilitates a reasonable to optimal, simultaneous visualization and assessment of the surface structure of the tracheobronchial system and the surrounding mediastinal structures and lesions. Hybrid rendering relieve the morphological assessment of anatomical and pathological changes without the need for time-consuming detailed analysis and presentation of source images. Performing virtual bronchoscopy with a transparent shaded-surface model offers a promising alternative to flexible fiberoptic bronchoscopy.

  10. Review of muon tomography

    International Nuclear Information System (INIS)

    Feng Hanliang; Jiao Xiaojing

    2010-01-01

    As a new detection technology, Muon tomography has some potential benefits, such as being able to form a three- dimensional image, without radiation, low cost, fast detecting etc. Especially, muon tomography will play an important role in detecting nuclear materials. It introduces the theory of Muon tomography, its advantages and the Muon tomography system developed by decision sciences corporation and Los Alamos national laboratory. (authors)

  11. Exploring Virtual Reality for Classroom Use: The Virtual Reality and Education Lab at East Carolina University.

    Science.gov (United States)

    Auld, Lawrence W. S.; Pantelidis, Veronica S.

    1994-01-01

    Describes the Virtual Reality and Education Lab (VREL) established at East Carolina University to study the implications of virtual reality for elementary and secondary education. Highlights include virtual reality software evaluation; hardware evaluation; computer-based curriculum objectives which could use virtual reality; and keeping current…

  12. Virtual Machine Logbook - Enabling virtualization for ATLAS

    International Nuclear Information System (INIS)

    Yao Yushu; Calafiura, Paolo; Leggett, Charles; Poffet, Julien; Cavalli, Andrea; Frederic, Bapst

    2010-01-01

    ATLAS software has been developed mostly on CERN linux cluster lxplus or on similar facilities at the experiment Tier 1 centers. The fast rise of virtualization technology has the potential to change this model, turning every laptop or desktop into an ATLAS analysis platform. In the context of the CernVM project we are developing a suite of tools and CernVM plug-in extensions to promote the use of virtualization for ATLAS analysis and software development. The Virtual Machine Logbook (VML), in particular, is an application to organize work of physicists on multiple projects, logging their progress, and speeding up ''context switches'' from one project to another. An important feature of VML is the ability to share with a single 'click' the status of a given project with other colleagues. VML builds upon the save and restore capabilities of mainstream virtualization software like VMware, and provides a technology-independent client interface to them. A lot of emphasis in the design and implementation has gone into optimizing the save and restore process to makepractical to store many VML entries on a typical laptop disk or to share a VML entry over the network. At the same time, taking advantage of CernVM's plugin capabilities, we are extending the CernVM platform to help increase the usability of ATLAS software. For example, we added the ability to start the ATLAS event display on any computer running CernVM simply by clicking a button in a web browser. We want to integrate seamlessly VML with CernVM unique file system design to distribute efficiently ATLAS software on every physicist computer. The CernVM File System (CVMFS) download files on-demand via HTTP, and cache it locally for future use. This reduces by one order of magnitude the download sizes, making practical for a developer to work with multiple software releases on a virtual machine.

  13. Borehole radar diffraction tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seong Jun; Kim, Jung Ho; Yi, Myeong Jong; Chung, Seung Hwan; Lee, Hee Il [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1997-12-01

    Tomography is widely used as imaging method for determining subsurface structure. Among the reconstruction algorithms for tomographic imaging, travel time tomography is almost applied to imaging subsurface. But isolated small body comparable with the wavelength could not be well recognized by travel time tomography. Other tomographic method are need to improve the imaging process. In the study of this year, diffraction tomography was investigated. The theory for diffraction tomography is based on the 1st-order Born approximation. Multisource holography, which is similar to Kirchihoff migration, is compared with diffraction tomography. To improve 1st-order Born diffraction tomography, two kinds of filter designed from multisource holography and 2-D green function, respectively, applied on the reconstructed image. The algorithm was tested for the numerical modeling data of which algorithm consists of the analytic computation of radar signal in transmitter and receiver regions and 2-D FDM scheme for the propagation of electromagnetic waves in media. The air-filled cavity model to show a typical diffraction pattern was applied to diffraction tomography imaging, and the result shows accurate location and area of cavity. But the calculated object function is not well matched the real object function, because the air-filled cavity model is not satisfied week scattered inhomogeneity for 1st born approximation, and the error term is included in estimating source wavelet from received signals. In spite of the object function error, the diffraction tomography assist for interpretation of subsurface as if conducted with travel time tomography. And the fracture model was tested, 1st born diffraction tomographic image is poor because of limited view angle coverage and violation of week scatter assumption, but the filtered image resolve the fracture somewhat better. The tested diffraction tomography image confirms effectiveness of filter for enhancing resolution. (author). 14

  14. Integrating hinge axis approximation and the virtual facial simulation of prosthetic outcomes for treatment with CAD-CAM immediate dentures: A clinical report of a patient with microstomia.

    Science.gov (United States)

    Kuric, Katelyn M; Harris, Bryan T; Morton, Dean; Azevedo, Bruno; Lin, Wei-Shao

    2017-09-29

    This clinical report describes a digital workflow using extraoral digital photographs and volumetric datasets from cone beam computed tomography (CBCT) imaging to create a 3-dimensional (3D), virtual patient with photorealistic appearance. In a patient with microstomia, hinge axis approximation, diagnostic casts simulating postextraction alveolar ridge profile, and facial simulation of prosthetic treatment outcome were completed in a 3D, virtual environment. The approach facilitated the diagnosis, communication, and patient acceptance of the treatment of maxillary and mandibular computer-aided design and computer-aided manufacturing (CAD-CAM) of immediate dentures at increased occlusal vertical dimension. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  15. On-line course as tools for radiation protection training in patients. A practical case in computerized tomography; El Aula Virtual como herramienta para la formacion en PR del paciente; caso practico en tomografia computarizada

    Energy Technology Data Exchange (ETDEWEB)

    Medina Campos, J.; Fernandez Tallon, J.; Busca Suau, J.; Baro Casanovas, J.

    2006-07-01

    The rise in ionizing radiation applications within the field of diagnostics, with the corresponding increase in both number and doses received by patients, requires adequate resources for education and training in radiological protection. In is quite difficult to assemble professionals at a specific place to carry out training. However, the use of Information and Communication Technologies (IT) makes it possible to carry out training. However, the use of Information and Communication Technologies (IT) makes it possible to carry out training through Internet in an effective, easy and amusing way (e-learning). An on-line course of patient radiological protection and quality control in computer tomography has been developed aimed at professionals that use these diagnostic techniques. The course has been run twice in the period 2005-2006. The course is found on an Internet-accessible Virtual Campus, which allows access to multimedia contents, communication between students and instructors and follow-up of students performance. Final evaluation is done on-line and successfully passing the course counts for 8.9 credits in the Continuous Education Programme of Spanish Health Systems. (Author)

  16. Virtual Seminar Room

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Fosgerau, Anders; Hansen, Peter Søren Kirk

    1999-01-01

    The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented.......The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented....

  17. A Virtual Commissioning Learning Platform

    DEFF Research Database (Denmark)

    Mortensen, Steffen; Madsen, Ole

    2018-01-01

    The introduction of reconfigurable manufacturing systems (RMS), Industry 4.0 and the associated technologies requires the establishment of new competencies. Towards that goal, Aalborg University (AAU) has developed an Industry 4.0 learning factory, the AAU Smart Production Lab. The AAU Smart...... Production Lab integrates a number of Industry 4.0 technologies for learning and research purposes. One of the many techniques is virtual commissioning. Virtual commissioning uses a virtual plant model and real controllers (PLCs) enabling a full emulation of the manufacturing system for verification. Virtual...... commissioning can lower the commissioning time up to 63%, allowing faster time to market. However, virtual commission is still missing industrial impact one of the reasons being lack of competencies and integration experiences. The paper presents the setup of the virtual commissioning learning platform...

  18. Virtual toolbox

    Science.gov (United States)

    Jacobus, Charles J.; Jacobus, Heidi N.; Mitchell, Brian T.; Riggs, A. J.; Taylor, Mark J.

    1993-04-01

    At least three of the five senses must be fully addressed in a successful virtual reality (VR) system. Sight, sound, and touch are the most critical elements for the creation of the illusion of presence. Since humans depend so much on sight to collect information about their environment, this area has been the focus of much of the prior art in virtual reality, however, it is also crucial that we provide facilities for force, torque, and touch reflection, and sound replay and 3-D localization. In this paper we present a sampling of hardware and software in the virtual environment maker's `toolbox' which can support rapidly building up of customized VR systems. We provide demonstrative examples of how some of the tools work and we speculate about VR applications and future technology needs.

  19. A Virtual History of Mauritius

    African Journals Online (AJOL)

    admpather

    University of Mauritius, Réduit, Mauritius. 116. A Virtual History ... out will be presented. Keywords: Virtual Heritage, Virtual Reality, Archaeology, Mauritius ... money would better be spent on other major education and IT development projects ...

  20. Effects of VIrtualIty on Employee Performance and CommItment: A Research

    OpenAIRE

    Baysal, Zeynep; Baraz, Barış

    2017-01-01

    In the modern business world, due to the impact of technological advancements and globalisation,organisations are obliged to keep up with the change in order to seize new opportunities they encounterand overcome the obstacles in their way. Concepts of virtuality and virtual organisations are amongthese concepts which surfaced as a result of these changes. All white-collar employees have a certaindegree of virtuality and the fact that organisations are taking rapid steps towards virtualisation...

  1. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  2. Virtual reality for employability skills

    OpenAIRE

    Minocha, Shailey; Tudor, Ana-Despina

    2017-01-01

    We showed a variety of virtual reality technologies, and through examples, we discussed how virtual reality technology is transforming work styles and workplaces. Virtual reality is becoming pervasive in almost all domains starting from arts, environmental causes to medical education and disaster management training, and to supporting patients with Dementia. Thus, an awareness of the virtual reality technology and its integration in curriculum design will provide and enhance employability ski...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... minimize any potential discomfort. Some physicians prescribe an antibiotic prior to and/or after the procedure. You ... Radiological Society of North America, Inc. (RSNA). To help ensure current and accurate information, we do not ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... remains in a patient's body after an x-ray examination. X-rays usually have no side effects in the ... Articles and Media Sonohysterography Uterine Fibroid Embolization (UFE) Radiation Dose in X-Ray and CT Exams Contrast Materials Abnormal Vaginal ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... of Use | Links | Site Map Copyright © 2018 Radiological Society of North America, Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... in a known abnormality can be monitored over time. Follow-up examinations are sometimes the best way ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... or internal organs in motion. Still images or movies are also captured and stored electronically on a computer. Until recently, x-ray images were maintained on large film sheets (much like a large photographic negative). Today, ...

  9. Hysterosalpingography

    Science.gov (United States)

    ... the area being examined by making it appear dark (or by electronically reversing the image contrast to ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... the area being examined by making it appear dark (or by electronically reversing the image contrast to ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... X-rays are a form of radiation like light or radio waves. X-rays pass through most objects, including the body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers top of page This page was reviewed on February 10, 2018 Send us your feedback Did you find the information you were ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... Please note RadiologyInfo.org is not a medical facility. Please contact your physician with specific medical questions ... your community, you can search the ACR-accredited facilities database . This website does not provide cost information. ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, allergies and medications you’re taking. This ... material . An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... her back on the exam table, with her knees bent or her feet held up with stirrups ... of the abdominal cavity, causing generalized lower abdominal pain, but this should also be minimal and not ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... uterus and fallopian tubes are filled with a water-soluble contrast material and the radiologist is able ... more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special ... About Us | Contact Us | FAQ | ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... in X-Ray and CT Exams Contrast Materials Abnormal Vaginal Bleeding Cervical ... or for a referral to a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... implant in the uterus. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic ... Send us your feedback Did you find the information you were looking for? Yes No Please type ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... of page Who interprets the results and how do I get them? A radiologist , a physician specifically ... E-mail: Area code: Phone no: Thank you! Do you have a personal story about radiology? Share ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit of an accurate ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... may also be asked to remove jewelry, removable dental appliances, eye glasses and any metal objects or ... and send a signed report to your primary care or referring physician , who will discuss the results ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... the area being examined by making it appear dark (or by electronically reversing the image contrast to ... x-ray examination. X-rays usually have no side effects in the typical diagnostic range for this ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... any scarring within the uterine or peritoneal (abdominal) cavity . The procedure can be used to investigate repeated ... contrast material then begins to fill the uterine cavity , fallopian tubes and peritoneal cavity through the catheter ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... exposing a part of the body to a small dose of ionizing radiation to produce pictures of ... being examined, an x-ray machine produces a small burst of radiation that passes through the body, ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... are also captured and stored electronically on a computer. Until recently, x-ray images were maintained on ... images for evaluation. National and international radiology protection organizations continually review and update the technique standards used ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... completed within 30 minutes. top of page What will I experience during and after the procedure? This ... specifically trained to supervise and interpret radiology examinations, will analyze the images and send a signed report ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... the body. X-rays are the oldest and most frequently used form of medical imaging. Fluoroscopy is ... light or radio waves. X-rays pass through most objects, including the body. Once it is carefully ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... at the time of the procedure. On the night before the procedure, you may be asked to ... an x-ray will be taken the next day to ensure that there is no scarring surrounding ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available ... may also be asked to remove jewelry, removable dental appliances, eye glasses and any metal objects or clothing that might interfere with the x-ray images. Women should always inform their physician and ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed regularly by a physician with expertise ... not responsible for the content contained on the web pages found at these links. About Us | Contact Us | ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is taken ... and/or your insurance provider to get a better understanding of the possible charges you will incur. ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... sexually transmitted disease. Wear loose, comfortable clothing and leave jewelry at home. You may be asked to ... are sometimes the best way to see if treatment is working or if a finding is stable ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... sexually transmitted disease. Wear loose, comfortable clothing and leave jewelry at home. You may be asked to ... may also be asked to remove jewelry, removable dental appliances, eye glasses ... sometimes the best way to see if treatment is working or if a finding is stable ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician ... minimize radiation exposure to the baby. See the Safety page for more information about pregnancy and x- ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... ovaries, wall of the uterus, and other pelvic structures may be evaluated with MRI or ultrasound. Infertility ... information you were looking for? Yes No Please type your comment or suggestion into the following text ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... images for evaluation. National and international radiology protection organizations continually review and update the technique standards used ... ovaries, wall of the uterus, and other pelvic structures may be evaluated with MRI or ultrasound. Infertility ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... a chronic pelvic infection or an untreated sexually transmitted disease. Wear loose, comfortable clothing and leave jewelry at ... a chronic pelvic infection or an untreated sexually transmitted disease at the time of the procedure. On the ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... through the body, recording an image on photographic film or a special detector. Fluoroscopy uses a continuous ... recently, x-ray images were maintained on large film sheets (much like a large photographic negative). Today, ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... you have any signs of pelvic infection or pelvic inflammatory disease. You will be asked to remove some of ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... areas. Outside links: For the convenience of our users, RadiologyInfo .org provides links to relevant ... To help ensure current and accurate information, we do not permit copying but encourage linking ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... The video is produced by the x-ray machine and a detector that is suspended over a ... of the body being examined, an x-ray machine produces a small burst of radiation that passes ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... Share your patient story here Related Articles and Media Sonohysterography Uterine Fibroid Embolization (UFE) Radiation Dose in X-Ray and CT Exams Contrast Materials Abnormal Vaginal Bleeding Cervical Cancer Endometrial Cancer ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR and RSNA are not ... To help ensure current and accurate information, we do not permit copying but encourage linking ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... electronically reversing the image contrast to white), this special x-ray technique makes it possible for the physician to view joints or internal organs in motion. Still images or movies are also captured and stored electronically on a ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, treatments ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed regularly by a physician with ... not responsible for the content contained on the web pages found at these links. About Us | Contact ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available ... minimize any potential discomfort. Some physicians prescribe an antibiotic prior to and/or after the procedure. You ... are sometimes the best way to see if treatment is working or if a finding is stable ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... and/or your insurance provider to get a better understanding of the possible charges you will incur. ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... stirrups and a speculum is inserted into the vagina. The cervix is then cleansed, and a catheter ... minimal and not long lasting. Most women experience vaginal spotting for a few days after the examination, ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Related Articles and ... Bleeding Cervical Cancer Endometrial Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Imaging with ... Radiological Society of North America, Inc. (RSNA). To help ensure current and accurate information, we do not ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... care is taken during x-ray examinations to use the lowest radiation dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site ... clothing that might interfere with the x-ray images. Women should always inform their physician and x- ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... reviewed on February 10, 2018 Send us your feedback Did you find the information you were looking ... procedures may vary by geographic region. Discuss the fees associated with your prescribed procedure with your doctor, ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... and send a signed report to your primary care or referring physician , who will discuss the results ... rays. A Word About Minimizing Radiation Exposure Special care is taken during x-ray examinations to use ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... one or two x-ray tubes and a television-like monitor that is located in the examining ... that are projected onto a fluorescent screen, or television-like monitor. When used with a contrast material, ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... you have any signs of pelvic infection or pelvic inflammatory disease. You will be asked to remove some of ... a large photographic negative). Today, most images are digital files that are stored electronically. These stored images ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... page was reviewed on February 10, 2018 Send us your feedback Did you find the information you were looking ... and Media Sonohysterography Uterine Fibroid Embolization (UFE) Radiation Dose in ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... after the procedure? This exam should cause only minor discomfort. There may be slight discomfort and cramping ... best images for evaluation. National and international radiology protection organizations continually review and update the technique standards ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... your physician or technologist if you have a chronic pelvic infection or an untreated sexually transmitted disease. ... your physician or technologist if you have a chronic pelvic infection or an untreated sexually transmitted disease ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... It’s also used to investigate miscarriages resulting from abnormalities within the uterus and to determine the presence ... repeated miscarriages that result from congenital or acquired abnormalities of the uterus and to determine the presence ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... of the fallopian tubes, and to monitor the effects of tubal surgery, including: Blockage of the fallopian ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... This website does not provide cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. Discuss the fees associated with your prescribed procedure with your doctor, ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... ray technique that makes it possible to see internal organs in motion. During a hysterosalpingogram, the uterus ... possible for the physician to view joints or internal organs in motion. Still images or movies are ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... the uterus. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers top ... To locate a medical imaging or radiation oncology provider in your community, you can search the ACR- ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available ... pregnant by allowing the radiologist to evaluate the shape and structure of the uterus, the openness of ... exam table, with her knees bent or her feet held up with stirrups and a speculum is ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... frequently compared to current x-ray images for diagnosis and disease management. top of page How is ... usually have no side effects in the typical diagnostic range for this exam. Risks There is always ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... a woman who is having difficulty becoming pregnant. It’s also used to investigate miscarriages resulting from abnormalities ... is a special x-ray technique that makes it possible to see internal organs in motion. During ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... When used with a contrast material, which clearly defines the area being examined by making it appear ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Fluoroscopy ... Share your patient story here Related Articles and Media ... Sponsored by Please note RadiologyInfo. ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... usually have no side effects in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit ... and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers top of page This page was reviewed on ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... a large photographic negative). Today, most images are digital files that are stored electronically. These stored images ... ACR and RSNA are not responsible for the content contained on the web pages found at these ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... allowing the radiologist to evaluate the shape and structure of the uterus, the openness of the fallopian ... your bowels, so that the uterus and surrounding structures can be seen clearly. Prior to the procedure, ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... of a woman who is having difficulty becoming pregnant. It’s also used to investigate miscarriages resulting from ... fallopian tubes to allow the patient to become pregnant afterwards. Tell your doctor if there’s a possibility ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... of the abdominal cavity, causing generalized lower abdominal pain, but this should also be minimal and not ... to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. The effective radiation dose ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... of the abdominal cavity, causing generalized lower abdominal pain, but this should also be minimal and not ... usually have no side effects in the typical diagnostic range for this exam. Risks There is always ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... an active inflammatory condition. Tell your physician or technologist if you have a chronic pelvic infection or ... inflammatory condition. You should notify your physician or technologist if you have a chronic pelvic infection or ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... laxative or an enema to empty your bowels, so that the uterus and surrounding structures can be ... Many imaging tests are not performed during pregnancy so as not to expose the fetus to radiation. ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... or suggestion into the following text box: Comment: E-mail: Area code: Phone no: Thank you! Do ... Recommend RadiologyInfo to a friend Send to (friend's e-mail address): From (your name): Your e-mail ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ... dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... pregnant. Many imaging tests are not performed during pregnancy so as not to expose the fetus to ... See the Safety page for more information about pregnancy and x-rays. top of page What does ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... examination may also be necessary so that any change in a known abnormality can be monitored over ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... minimize radiation exposure to the baby. See the Safety page for more information about pregnancy and x- ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... for more information about radiation dose. In the event of a chronic inflammatory condition, pelvic infection or ...

  13. Hysterosalpingography

    Medline Plus

    Full Text Available ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ... message (optional): Bees: Wax: Notice: RadiologyInfo respects your privacy. Information entered here will not be used for ...

  14. Hysterosalpingography

    Medline Plus

    Full Text Available ... no: Thank you! Do you have a personal story about radiology? Share your patient story here Related ... Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 Radiological Society of North America, Inc. ( ...

  15. Hysterosalpingography

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... radiation dose for this procedure varies. See the Safety page for more ... condition, pelvic infection or untreated sexually transmitted disease, be ...

  16. Hysterosalpingography

    Medline Plus

    Full Text Available ... clothing that might interfere with the x-ray images. Women should always inform their physician and x-ray ... lowest radiation dose possible while producing the best images for ... organizations continually review and update the technique standards used ...

  17. Hysterosalpingography

    Medline Plus

    Full Text Available ... not responsible for the content contained on the web pages found at these links. About ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  18. Hysterosalpingography

    Medline Plus

    Full Text Available ... fluoroscopy to view and assess their anatomy and function. top of page What are some common uses ... a form of radiation like light or radio waves. X-rays pass through most objects, including the ...

  19. Hysterosalpingography

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  20. Hysterosalpingography

    Medline Plus

    Full Text Available ... reviewed on February 10, 2018 Send us your feedback Did you find the information you were looking ... of North America, Inc. (RSNA). To help ensure current and accurate information, we do not permit copying ...

  1. Hysterosalpingography

    Medline Plus

    Full Text Available ... Radiology (ACR) and the Radiological Society of North America (RSNA), comprising physicians with expertise in several radiologic ... Site Map Copyright © 2018 Radiological Society of North America, Inc. (RSNA). To help ensure current and accurate ...

  2. Hysterosalpingography

    Medline Plus

    Full Text Available ... examine the uterus and fallopian tubes of a woman who is having difficulty becoming pregnant. It’s also ... uterosalpingography, is an x-ray examination of a woman's uterus and fallopian tubes that uses a special ...

  3. Hysterosalpingography

    Medline Plus

    Full Text Available ... more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is taken ... for the content contained on the web pages found at these links. About Us | Contact Us | FAQ | ...

  4. Hysterosalpingography

    Medline Plus

    Full Text Available ... uterus and fallopian tubes are filled with a water-soluble contrast material and the radiologist is able ... more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care ... About Us | Contact Us | FAQ | ...

  5. Hysterosalpingography

    Medline Plus

    Full Text Available ... are not responsible for the content contained on the web pages found at these links. ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  6. Hysterosalpingography

    Medline Plus

    Full Text Available ... of the body to a small dose of ionizing radiation to produce pictures of the inside of ... a form of radiation like light or radio waves. X-rays pass through most objects, including the ...

  7. Hysterosalpingography

    Medline Plus

    Full Text Available ... the oldest and most frequently used form of medical imaging. Fluoroscopy is a special x-ray technique that ... a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  8. Hysterosalpingography

    Medline Plus

    Full Text Available ... You should inform your physician of any medications being taken and if there are any allergies, especially ... carefully aimed at the part of the body being examined, an x-ray machine produces a small ...

  9. Hysterosalpingography

    Medline Plus

    Full Text Available ... conditions. Imaging with x-rays involves exposing a part of the body to a small dose of ... body. Once it is carefully aimed at the part of the body being examined, an x-ray ...

  10. Hysterosalpingography

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ... minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive ...

  11. Hysterosalpingography

    Medline Plus

    Full Text Available ... pregnant and discuss any recent illnesses, medical conditions, allergies and medications you’re taking. This procedure should ... medications being taken and if there are any allergies, especially to iodinated contrast materials . Also inform your ...

  12. Hysterosalpingography

    Medline Plus

    Full Text Available ... used to investigate repeated miscarriages that result from congenital or acquired abnormalities of the uterus and to ... of the fallopian tubes following a sterilization or disease-related blockage top of page How should I ...

  13. Virtual Campus Hub technology

    DEFF Research Database (Denmark)

    Vercoulen, Frank; Badger, Merete; Monaco, Lucio

    This deliverable briefly describes which technological components have been delivered for the Virtual Campus Hub and how they can be used. A detailed discussion of the technical details of the components, how they were realized and how they fit the VCH concept can be found in deliverables D5.......4. Virtual Campus Hub Technology Evaluation Report and D6.7 The Virtual Campus Hub Concept....

  14. Real and virtual radiation

    International Nuclear Information System (INIS)

    Wolynec, E.

    1988-01-01

    Electrodisintegration cross sections related to the corresponding photonuclear process through virtual-photon spectra. A brief review of virtual-photon theory is presented. Calculations of DWBA virtual-photon spectra for finite nuclei are compared with experimental results. The multipole decomposition of electrodisintegration cross sections using these spectra is discussed and several experimental results are presented. A brief review for the bremsstrahlung cross section is also presented. (author) [pt

  15. Varieties of virtualization

    Science.gov (United States)

    Ellis, Stephen R.

    1991-01-01

    Natural environments have a content, i.e., the objects in them; a geometry, i.e., a pattern of rules for positioning and displacing the objects; and a dynamics, i.e., a system of rules describing the effects of forces acting on the objects. Human interaction with most common natural environments has been optimized by centuries of evolution. Virtual environments created through the human-computer interface similarly have a content, geometry, and dynamics, but the arbitrary character of the computer simulation creating them does not insure that human interaction with these virtual environments will be natural. The interaction, indeed, could be supernatural but it also could be impossible. An important determinant of the comprehensibility of a virtual environment is the correspondence between the environmental frames of reference and those associated with the control of environmental objects. The effects of rotation and displacement of control frames of reference with respect to corresponding environmental references differ depending upon whether perceptual judgement or manual tracking performance is measured. The perceptual effects of frame of reference displacement may be analyzed in terms of distortions in the process of virtualizing the synthetic environment space. The effects of frame of reference displacement and rotation have been studied by asking subjects to estimate exocentric direction in a virtual space.

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  17. Occupational Radiation Exposure to the Extremities of Medical Staff during Hysterosalpingography and Radionuclide Bone Scan Procedures in Several Nigerian Hospitals

    Directory of Open Access Journals (Sweden)

    Nnamdi Norbert Jibiri

    2016-10-01

    Full Text Available Objective: The practice of regular dose measurement helps to ascertain the level of occupational dose delivered to the staff involved in diagnostic procedures. This study was carried out to evaluate the dose exposed to the hands of radiologists and a radiologic technologist carrying out HSG and radionuclide bone scan examinations in several hospitals in Nigeria. Methods: Radiation doses exposed to the hands of radiologists and a technician carrying out hysterosalpingography (HSG and bone scan procedures were measured using calibrated thermo-luminescent dosimeters. Five radiologists and a radiologic technologist were included in the study for dose measurement. Results: The study indicates that each radiologist carried out approximately 2 examinations per week with the mean dose ranging between 0.49-0.62 mSv per week, resulting in an annual dose of 191 mSv. Similarly, the occupational dose delivered to both the left and right hands of a radiologic technologist administering 99mTc-methylene diphosphonate (MDP without cannula and with cannula were 10.68 (720.2 and 13.82 (556.4 mSv per week (and per annum, respectively. It was determined that the left hand of the personnel received higher doses than their right hand. Conclusion: The estimated annual dose during HSG is far below the annual dose limit for deterministic effects, however, it is greater than 10% of the applicable annual dose limit. Hence, routine monitoring is required to ensure adequate protection of the personnel. The total annual dose received during the bone scan exceeds the annual dose limit for both hands, and the dose to either left or right hand is greater than the dose limit of 500 mSv/yr. The radiologists monitored are not expected to incur any deterministic effects during HSG examinations, however, accumulated doses arising from the scattered radiation to the eyes, legs, and neck could be substantial and might lead to certain effects. More staff are required to administer 99m

  18. Cooperation, Coordination, and Trust in Virtual Teams: Insights from Virtual Games

    Science.gov (United States)

    Korsgaard, M. Audrey; Picot, Arnold; Wigand, Rolf T.; Welpe, Isabelle M.; Assmann, Jakob J.

    This chapter considers fundamental concepts of effective virtual teams, illustrated by research on Travian, a massively multiplayer online strategy game wherein players seek to build empires. Team inputs are the resources that enable individuals to work interdependently toward a common goal, including individual and collective capabilities, shared knowledge structures, and leadership style. Team processes, notably coordination and cooperation, transform team inputs to desired collective outcomes. Because the members of virtual teams are geographically dispersed, relying on information and communication technology, three theories are especially relevant for understanding how they can function effectively: social presence theory, media richness theory, and media synchronicity theory. Research in settings like Travian can inform our understanding of structures, processes, and performance of virtual teams. Such research could provide valuable insight into the emergence and persistence of trust and cooperation, as well as the impact of different communication media for coordination and information management in virtual organizations.

  19. ROLE OF VIRTUALIZATION IN CLOUD COMPUTING

    OpenAIRE

    Avneet kaur; Dr. Gaurav Gupta; Dr. Gurjit Singh Bhathal

    2017-01-01

    Cloud Computing is the fundamental change happening in the field of Information Technology.. Virtualization is the key component of cloud computing. With the use of virtualization, cloud computing brings about not only convenience and efficiency benefits, but also great challenges in the field of data security and privacy protection. .In this paper, we are discussing about virtualization, architecture of virtualization technology as well as Virtual Machine Monitor (VMM). Further discussing ab...

  20. Virtual care

    DEFF Research Database (Denmark)

    Kamp, Annette; Aaløkke Ballegaard, Stinne

    of retrenchment, promising better quality, empowerment of citizens and work that is smarter and more qualified. Through ethnographic field studies we study the introduction of virtual home care in Danish elderly care, focusing on the implications for relational work and care relations. Virtual home care entails...... the performance of specific home care services by means of video conversations rather than physical visits in the citizens’ homes. As scholars within the STS tradition maintain, technologies do not simply replace a human function; they rather transform care work, redistributing tasks between citizens, technology...... point out how issues of trust and surveillance, which are always negotiated in care relations, are in fact accentuated in this kind of virtual care work. Moreover, we stress that the contemporary institutional context, organization and time schedules have a vast impact on the practices developed....

  1. A radiologic analysis and comparative evaluation of hysterosalpingographic and laparoscopic findings in infertile patients

    International Nuclear Information System (INIS)

    Lee, Hang Young; Kim, Soo Won; Chung, Hye Kyung; Yu, Yun Jeong

    1984-01-01

    Hystreosalpingogram of 375 patients with infertility were reviewed with reference to radiological feature of each pathology and a comparative study of hysterosalpingography and laparoscopy in 36 patients was presented. This results were as follows;1. In 375 cases of infertility, 191 cases (50.9%) were primary infertility and 181 cases (49.1%) were secondary infertility. 2. The peak age distribution was 26 to 30 year old group in 211 cases (56.3%), and the peak duration of infertility was less than 3 years in 256 cases (68.3%). 3. Abnormal uterine findings were 115 cases (30.7%) and there were 73 cases of filling defects, 13 cases of irregularity, 12 cases of uterine flexion, 11 cases of congenital anomaly, and 9 cases of hypoplasia among them. 4. Abnormal tubal findings were 196 cases (52.3%) and there were 103 cases of simple obstruction, 69 cases of hydrosalpinx, and 50 cases of peritubal adhesion among them. 5. Intravasation of contrast media was noted in 42 cases (11.2%). 6. In 36 cases of laparoscopy, 23 cases (63.7%) was agreed to hysterosalpingography. 7. Although laparoscopy was better than hysterosalpingography in external anatomy of salpinx and relationship to ovary, hysterosalpingography should be important for fundamental study of infertile women because of lower failure rate, lower risk of complications, therapeutic effect, and lower cost.

  2. vSphere virtual machine management

    CERN Document Server

    Fitzhugh, Rebecca

    2014-01-01

    This book follows a step-by-step tutorial approach with some real-world scenarios that vSphere businesses will be required to overcome every day. This book also discusses creating and configuring virtual machines and also covers monitoring virtual machine performance and resource allocation options. This book is for VMware administrators who want to build their knowledge of virtual machine administration and configuration. It's assumed that you have some experience with virtualization administration and vSphere.

  3. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  4. APLIKASI SERVER VIRTUAL IP UNTUK MIKROKONTROLER

    OpenAIRE

    Ashari, Ahmad

    2008-01-01

    Selama ini mikrokontroler yang terhubung ke satu komputer hanya dapat diakses melalui satu IP saja, padahal kebanyakan sistem operasi sekarang dapat memperjanjikan lebih dari satu IP untuk setiap komputer dalam bentuk virtual IP. Penelitian ini mengkaji pemanfaatan virtual IP dari IP aliasing pada sistem operasi Linux sebagai Server Virtual IP untuk mikrokontroler. Prinsip dasar Server Virtual IP adalah pembuatan Virtual Host pada masing-masing IP untuk memproses paket-paket data dan menerjem...

  5. Security challenges for virtualization in cloud

    International Nuclear Information System (INIS)

    Tayab, A.

    2015-01-01

    Virtualization is a model that is vastly growing in IT industry. Virtualization provides more than one logical resource in one single physical machine. Infrastructure use cloud services and on behalf of virtualization, cloud computing is also a rapidly growing model of IT industry. Cloud provider and cloud user, both remain ignorant of each other's security. Since virtualization and cloud computing are rapidly expanding and becoming more and more complex in infrastructure, more security is required to protect them from potential attacks and security threats. Virtualization provides various benefits in terms of hardware utilization, resources protection, remote access and other resources. This paper intends to discuss the common exploits of security uses in the virtualized environment and focuses on the security threats from the attacker's perspective. This paper discuss the major areas of virtualized model environment and also address the security concerns. And finally presents a solution for secure valorization in IT infrastructure and to protect inter communication of virtual machines. (author)

  6. Talking with a Virtual Human : Controlling the Human Experience and Behavior in a Virtual Conversation

    NARCIS (Netherlands)

    Qu, C.

    2014-01-01

    Virtual humans are often designed to replace real humans in virtual reality applications for e.g., psychotherapy, education and entertainment. In general, applications with virtual humans are created for modifying a person's knowledge, beliefs, attitudes, emotions or behaviors. Reaching these

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  9. Diagnostic accuracy in virtual dermatopathology

    DEFF Research Database (Denmark)

    Mooney, E.; Kempf, W.; Jemec, G.B.E.

    2012-01-01

    Background Virtual microscopy is used for teaching medical students and residents and for in-training and certification examinations in the United States. However, no existing studies compare diagnostic accuracy using virtual slides and photomicrographs. The objective of this study was to compare...... diagnostic accuracy of dermatopathologists and pathologists using photomicrographs vs. digitized images, through a self-assessment examination, and to elucidate assessment of virtual dermatopathology. Methods Forty-five dermatopathologists and pathologists received a randomized combination of 15 virtual...... slides and photomicrographs with corresponding clinical photographs and information in a self-assessment examination format. Descriptive data analysis and comparison of groups were performed using a chi-square test. Results Diagnostic accuracy in dermatopathology using virtual dermatopathology...

  10. International virtual teams engineering global success

    CERN Document Server

    Brewer, P

    2015-01-01

    As a complete guide to international virtual team communication with practical problem-solving strategies, this book is a must read for managers and engineers in all stages of their professional development This book provides essential information for creating and maintaining successful international virtual teams for those who manage, participate in, or train others in international virtual teaming. Based on new studies in engineering communication, this book presents processes and principles that can help managers and engineers establish global virtual teams that work, assess the virtual team climate, and maintain the effectiveness of virtual teams across cultural boundaries. It provides knowledge and tools necessary to understand the variable contexts of global virtual teams, so that organizations are able to respond to inevitable changes in technology and the global marketplace.

  11. Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography and (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for recurrent prostate carcinoma: results of a prospective clinical trial.

    Science.gov (United States)

    Schuster, David M; Nieh, Peter T; Jani, Ashesh B; Amzat, Rianot; Bowman, F Dubois; Halkar, Raghuveer K; Master, Viraj A; Nye, Jonathon A; Odewole, Oluwaseun A; Osunkoya, Adeboye O; Savir-Baruch, Bital; Alaei-Taleghani, Pooneh; Goodman, Mark M

    2014-05-01

    We prospectively evaluated the amino acid analogue positron emission tomography radiotracer anti-3-[(18)F]FACBC compared to ProstaScint® ((111)In-capromab pendetide) single photon emission computerized tomography-computerized tomography to detect recurrent prostate carcinoma. A total of 93 patients met study inclusion criteria who underwent anti-3-[(18)F]FACBC positron emission tomography-computerized tomography plus (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for suspected recurrent prostate carcinoma within 90 days. Reference standards were applied by a multidisciplinary board. We calculated diagnostic performance for detecting disease. In the 91 of 93 patients with sufficient data for a consensus on the presence or absence of prostate/bed disease anti-3-[(18)F]FACBC had 90.2% sensitivity, 40.0% specificity, 73.6% accuracy, 75.3% positive predictive value and 66.7% negative predictive value compared to (111)In-capromab pendetide with 67.2%, 56.7%, 63.7%, 75.9% and 45.9%, respectively. In the 70 of 93 patients with a consensus on the presence or absence of extraprostatic disease anti-3-[(18)F]FACBC had 55.0% sensitivity, 96.7% specificity, 72.9% accuracy, 95.7% positive predictive value and 61.7% negative predictive value compared to (111)In-capromab pendetide with 10.0%, 86.7%, 42.9%, 50.0% and 41.9%, respectively. Of 77 index lesions used to prove positivity histological proof was obtained in 74 (96.1%). Anti-3-[(18)F]FACBC identified 14 more positive prostate bed recurrences (55 vs 41) and 18 more patients with extraprostatic involvement (22 vs 4). Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography correctly up-staged 18 of 70 cases (25.7%) in which there was a consensus on the presence or absence of extraprostatic involvement. Better diagnostic performance was noted for anti-3-[(18)F]FACBC positron emission tomography-computerized tomography than for (111)In-capromab pendetide single

  12. Distributed Virtual Reality: System Concepts for Cooperative Training and Commanding in Virtual Worlds

    Directory of Open Access Journals (Sweden)

    Eckhard Freund

    2003-02-01

    Full Text Available The general aim of the development of virtual reality technology for automation applications at the IRF is to provide the framework for Projective Virtual Reality which allows users to "project" their actions in the virtual world into the real world primarily by means of robots but also by other means of automation. The framework is based on a new task-oriented approach which builds on the "task deduction" capabilities of a newly developed virtual reality system and a task planning component. The advantage of this new approach is that robots which work at great distances from the control station can be controlled as easily and intuitively as robots that work right next to the control station. Robot control technology now provides the user in the virtual world with a "prolonged arm" into the physical environment, thus paving the way for a new quality of userfriendly man machine interfaces for automation applications. Lately, this work has been enhanced by a new structure that allows to distribute the virtual reality application over multiple computers. With this new step, it is now possible for multiple users to work together in the same virtual room, although they may physically be thousands of miles apart. They only need an Internet or ISDN connection to share this new experience. Last but not least, the distribution technology has been further developed to not just allow users to cooperate but to be able to run the virtual world on many synchronized PCs so that a panorama projection or even a cave can be run with 10 synchronized PCs instead of high-end workstations, thus cutting down the costs for such a visualization environment drastically and allowing for a new range of applications.

  13. Software for virtual accelerator designing

    International Nuclear Information System (INIS)

    Kulabukhova, N.; Ivanov, A.; Korkhov, V.; Lazarev, A.

    2012-01-01

    The article discusses appropriate technologies for software implementation of the Virtual Accelerator. The Virtual Accelerator is considered as a set of services and tools enabling transparent execution of computational software for modeling beam dynamics in accelerators on distributed computing resources. Distributed storage and information processing facilities utilized by the Virtual Accelerator make use of the Service-Oriented Architecture (SOA) according to a cloud computing paradigm. Control system tool-kits (such as EPICS, TANGO), computing modules (including high-performance computing), realization of the GUI with existing frameworks and visualization of the data are discussed in the paper. The presented research consists of software analysis for realization of interaction between all levels of the Virtual Accelerator and some samples of middle-ware implementation. A set of the servers and clusters at St.-Petersburg State University form the infrastructure of the computing environment for Virtual Accelerator design. Usage of component-oriented technology for realization of Virtual Accelerator levels interaction is proposed. The article concludes with an overview and substantiation of a choice of technologies that will be used for design and implementation of the Virtual Accelerator. (authors)

  14. Virtual currencies : Real opportunities?

    OpenAIRE

    Selldahl, Sara

    2013-01-01

    AbstractThe European Central Bank defines virtual currencies as ”unregulated, digital money, which is issued and usuallycontrolled by its developers, and used and accepted among the members of a specific virtual community.”(European Central Bank, 2012, p. 5) The interest in virtual currencies has increased immensely over the last fewyears as they become increasingly prevalent in our society across many different industries. Up until now, the field ofvirtual currencies has been mainly uncharte...

  15. Corporate Training in Virtual Worlds

    Directory of Open Access Journals (Sweden)

    Charles Nebolsky

    2004-12-01

    Full Text Available This paper presents virtual training worlds that are relatively low-cost distributed collaborative learning environments suitable for corporate training. A virtual training world allows a facilitator, experts and trainees communicating and acting in the virtual environment for practicing skills during collaborative problem solving. Using these environments is beneficial to both trainees and corporations. Two system prototypes – the sales training and the leadership training virtual worlds – are described. The leadership training course design is discussed in details.

  16. Sense of presence and anxiety during virtual social interactions between a human and virtual humans

    OpenAIRE

    Morina, Nexhmedin; Brinkman, Willem-Paul; Hartanto, Dwi; Emmelkamp, Paul M.G.

    2014-01-01

    Virtual reality exposure therapy (VRET) has been shown to be effective in treatment of anxiety disorders. Yet, there is lack of research on the extent to which interaction between the individual and virtual humans can be successfully implanted to increase levels of anxiety for therapeutic purposes. This proof-of-concept pilot study aimed at examining levels of the sense of presence and anxiety during exposure to virtual environments involving social interaction with virtual humans and using d...

  17. State Virtual Libraries

    Science.gov (United States)

    Pappas, Marjorie L.

    2003-01-01

    Virtual library? Electronic library? Digital library? Online information network? These all apply to the growing number of Web-based resource collections managed by consortiums of state library entities. Some, like "INFOhio" and "KYVL" ("Kentucky Virtual Library"), have been available for a few years, but others are just starting. Searching for…

  18. CEDS Addresses: Virtual and Blended Learning

    Science.gov (United States)

    US Department of Education, 2015

    2015-01-01

    The Common Education Data Standards (CEDS) common data vocabulary supports the collection and use of information about virtual and blended learning. The data element "Virtual Indicator", introduced in version 3 of CEDS, supports a range of virtual learning-related use cases. The Virtual Indicator element may be related to a Course…

  19. Anatomy-Specific Virtual Reality Simulation in Temporal Bone Dissection: Perceived Utility and Impact on Surgeon Confidence.

    Science.gov (United States)

    Locketz, Garrett D; Lui, Justin T; Chan, Sonny; Salisbury, Kenneth; Dort, Joseph C; Youngblood, Patricia; Blevins, Nikolas H

    2017-06-01

    Objective To evaluate the effect of anatomy-specific virtual reality (VR) surgical rehearsal on surgeon confidence and temporal bone dissection performance. Study Design Prospective pre- and poststudy of a novel virtual surgical rehearsal platform. Setting Academic otolaryngology-head and neck surgery residency training programs. Subjects and Methods Sixteen otolaryngology-head and neck surgery residents from 2 North American training institutions were recruited. Surveys were administered to assess subjects' baseline confidence in performing 12 subtasks of cortical mastoidectomy with facial recess. A cadaver temporal bone was randomly assigned to each subject. Cadaver specimens were scanned with a clinical computed tomography protocol, allowing the creation of anatomy-specific models for use in a VR surgical rehearsal platform. Subjects then rehearsed a virtual mastoidectomy on data sets derived from their specimens. Surgical confidence surveys were administered again. Subjects then dissected assigned cadaver specimens, which were blindly graded with a modified Welling scale. A final survey assessed the perceived utility of rehearsal on dissection performance. Results Of 16 subjects, 14 (87.5%) reported a significant increase in overall confidence after conducting an anatomy-specific VR rehearsal. A significant correlation existed between perceived utility of rehearsal and confidence improvement. The effect of rehearsal on confidence was dependent on trainee experience and the inherent difficulty of the surgical subtask. Postrehearsal confidence correlated strongly with graded dissection performance. Subjects rated anatomy-specific rehearsal as having a moderate to high contribution to their dissection performance. Conclusion Anatomy-specific virtual rehearsal improves surgeon confidence in performing mastoid dissection, dependent on surgeon experience and task difficulty. The subjective confidence gained through rehearsal correlates positively with subsequent

  20. Virtual Reality for Anxiety Disorders

    Directory of Open Access Journals (Sweden)

    Elif Uzumcu

    2018-03-01

    Full Text Available Virtual reality is a relatively new exposure tool that uses three-dimensional computer-graphics-based technologies which allow the individual to feel as if they are physically inside the virtual environment by misleading their senses. As virtual reality studies have become popular in the field of clinical psychology in recent years, it has been observed that virtual-reality-based therapies have a wide range of application areas, especially on anxiety disorders. Studies indicate that virtual reality can be more realistic than mental imagery and can create a stronger feeling of ԰resenceԻ that it is a safer starting point compared to in vivo exposure; and that it can be applied in a more practical and controlled manner. The aim of this review is to investigate exposure studies based on virtual reality in anxiety disorders (specific phobias, panic disorder and agoraphobias, generalized anxiety disorder, social phobia, posttraumatic stress disorder and obsessive compulsive disorder.

  1. The ethnography of virtual reality

    Directory of Open Access Journals (Sweden)

    Gavrilović Ljiljana 1

    2004-01-01

    Full Text Available This paper discusses possible application of ethnographic research in the realm of virtual reality, especially in the relationship between cultures in virtual communities. This represents an entirely new area of ethnographic research and therefore many adjustments in the research design are needed for example, a development of a specific method of data gathering and tools for their verification. A virtual, cyber space is a version of social space more or less synchronous with it, but without the, "real", that is, physical presence of the people who create it. This virtual reality, defined and bounded by virtual space, is in fact real - and though we are not able to observe real, physical parameters of its existence, we can perceive its consequences. In sum, an innovative ethnographic research method is fully applicable for exploring the realm of virtual reality; in order to do so we need to expand, in addition to the new research design and methods, the field of science itself.

  2. Virtual reality technology and applications

    CERN Document Server

    Mihelj, Matjaž; Beguš, Samo

    2014-01-01

    As virtual reality expands from the imaginary worlds of science fiction and pervades every corner of everyday life, it is becoming increasingly important for students and professionals alike to understand the diverse aspects of this technology. This book aims to provide a comprehensive guide to the theoretical and practical elements of virtual reality, from the mathematical and technological foundations of virtual worlds to the human factors and the applications that enrich our lives: in the fields of medicine, entertainment, education and others. After providing a brief introduction to the topic, the book describes the kinematic and dynamic mathematical models of virtual worlds. It explores the many ways a computer can track and interpret human movement, then progresses through the modalities that make up a virtual world: visual, acoustic and haptic. It explores the interaction between the actual and virtual environments, as well as design principles of the latter. The book closes with an examination of diff...

  3. Surgery applications of virtual reality

    Science.gov (United States)

    Rosen, Joseph

    1994-01-01

    Virtual reality is a computer-generated technology which allows information to be displayed in a simulated, bus lifelike, environment. In this simulated 'world', users can move and interact as if they were actually a part of that world. This new technology will be useful in many different fields, including the field of surgery. Virtual reality systems can be used to teach surgical anatomy, diagnose surgical problems, plan operations, simulate and perform surgical procedures (telesurgery), and predict the outcomes of surgery. The authors of this paper describe the basic components of a virtual reality surgical system. These components include: the virtual world, the virtual tools, the anatomical model, the software platform, the host computer, the interface, and the head-coupled display. In the chapter they also review the progress towards using virtual reality for surgical training, planning, telesurgery, and predicting outcomes. Finally, the authors present a training system being developed for the practice of new procedures in abdominal surgery.

  4. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  5. Virtual Sustainability

    Directory of Open Access Journals (Sweden)

    William Sims Bainbridge

    2010-09-01

    Full Text Available In four ways, massively multiplayer online role-playing games may serve as tools for advancing sustainability goals, and as laboratories for developing alternatives to current social arrangements that have implications for the natural environment. First, by moving conspicuous consumption and other usually costly status competitions into virtual environments, these virtual worlds might reduce the need for physical resources. Second, they provide training that could prepare individuals to be teleworkers, and develop or demonstrate methods for using information technology to replace much transportation technology, notably in commuting. Third, virtual worlds and online games build international cooperation, even blending national cultures, thereby inching us toward not only the world consciousness needed for international agreements about the environment, but also toward non-spatial government that cuts across archaic nationalisms. Finally, realizing the potential social benefits of this new technology may urge us to reconsider a number of traditional societal institutions.

  6. Virtual Tower

    International Nuclear Information System (INIS)

    Wayne, R.A.

    1997-01-01

    The primary responsibility of an intrusion detection system (IDS) operator is to monitor the system, assess alarms, and summon and coordinate the response team when a threat is acknowledged. The tools currently provided to the operator are somewhat limited: monitors must be switched, keystrokes must be entered to call up intrusion sensor data, and communication with the response force must be maintained. The Virtual tower is an operator interface assembled from low-cost commercial-off-the-shelf hardware and software; it enables large amounts of data to be displayed in a virtual manner that provides instant recognition for the operator and increases assessment accuracy in alarm annunciator and control systems. This is accomplished by correlating and fusing the data into a 360-degree visual representation that employs color, auxiliary attributes, video, and directional audio to prompt the operator. The Virtual Tower would be a valuable low-cost enhancement to existing systems

  7. Development of a Virtual Museum Including a 4d Presentation of Building History in Virtual Reality

    Science.gov (United States)

    Kersten, T. P.; Tschirschwitz, F.; Deggim, S.

    2017-02-01

    In the last two decades the definition of the term "virtual museum" changed due to rapid technological developments. Using today's available 3D technologies a virtual museum is no longer just a presentation of collections on the Internet or a virtual tour of an exhibition using panoramic photography. On one hand, a virtual museum should enhance a museum visitor's experience by providing access to additional materials for review and knowledge deepening either before or after the real visit. On the other hand, a virtual museum should also be used as teaching material in the context of museum education. The laboratory for Photogrammetry & Laser Scanning of the HafenCity University Hamburg has developed a virtual museum (VM) of the museum "Alt-Segeberger Bürgerhaus", a historic town house. The VM offers two options for visitors wishing to explore the museum without travelling to the city of Bad Segeberg, Schleswig-Holstein, Germany. Option a, an interactive computer-based, tour for visitors to explore the exhibition and to collect information of interest or option b, to immerse into virtual reality in 3D with the HTC Vive Virtual Reality System.

  8. Image Based Rendering and Virtual Reality

    DEFF Research Database (Denmark)

    Livatino, Salvatore

    The Presentation concerns with an overview of Image Based Rendering approaches and their use on Virtual Reality, including Virtual Photography and Cinematography, and Mobile Robot Navigation.......The Presentation concerns with an overview of Image Based Rendering approaches and their use on Virtual Reality, including Virtual Photography and Cinematography, and Mobile Robot Navigation....

  9. Saving Money and Time with Virtual Server

    CERN Document Server

    Sanders, Chris

    2006-01-01

    Microsoft Virtual Server 2005 consistently proves to be worth its weight in gold, with new implementations thought up every day. With this product now a free download from Microsoft, scores of new users are able to experience what the power of virtualization can do for their networks. This guide is aimed at network administrators who are interested in ways that Virtual Server 2005 can be implemented in their organizations in order to save money and increase network productivity. It contains information on setting up a virtual network, virtual consolidation, virtual security, virtual honeypo

  10. Management and Engineering of Virtual Enterprises

    DEFF Research Database (Denmark)

    Tølle, Martin

    ) Component layer: consists of reusable components and modules. - Each layer builds on the previous one, i.e. the VE concept is captured in VERA, and the VERA can be used to structure each of the VERAM components. * C) A methodology for virtual enterprise named VEM (Virtual Enterprise Methodology) - One...... to the set up of virtual enterprises. Types of work preparation include definitions (e.g. shared terminology), ICT support (e.g. infrastructure and applications), procedures (e.g. how to set up virtual enterprises, partner selection), reference models (e.g. contract models and product structure) and the like....... * B) A framework and a reference architecture for virtual enterprises named VERAM (Virtual Enterprise Reference Architecture and Methodology) and VERA (Virtual Enterprise Reference Architecture) respectively. - VERAM is a framework that structures the body of knowledge related to preparation, set up...

  11. Virtual Reality in the Classroom.

    Science.gov (United States)

    Pantelidis, Veronica S.

    1993-01-01

    Considers the concept of virtual reality; reviews its history; describes general uses of virtual reality, including entertainment, medicine, and design applications; discusses classroom uses of virtual reality, including a software program called Virtus WalkThrough for use with a computer monitor; and suggests future possibilities. (34 references)…

  12. Interacting with a Virtual Conductor

    NARCIS (Netherlands)

    Bos, Pieter; Reidsma, Dennis; Ruttkay, Zsófia; Nijholt, Anton; Harper, Richard; Rauterberg, Matthias; Combetto, Marco

    This paper presents a virtual embodied agent that can conduct musicians in a live performance. The virtual conductor conducts music specified by a MIDI file and uses input from a microphone to react to the tempo of the musicians. The current implementation of the virtual conductor can interact with

  13. Dual energy virtual CT colonoscopy with dual source computed tomography. Initial experience

    International Nuclear Information System (INIS)

    Karcaaltincaba, M.; Karaosmanoglu, D.; Akata, D.; Sentuerk, S.; Oezmen, M.; Alibek, S.

    2009-01-01

    Purpose: To describe the technique of DE MDCT colonoscopy and to assess its feasibility. Materials and Methods: 8 patients were scanned with DSCT with a DE scan protocol and dose modulation software. Analysis was performed using dedicated DE software. Prone non-contrast images and DE supine images after contrast injection were obtained. Results: DE colonoscopic images were successfully obtained in 7 patients, but the FOV did not cover all colonic segments in 1 patient, thus resulting in a technical success rate was 87.5%. Streak artifacts were present in the pelvic region in 2 patients. Virtual unenhanced images and iodine map images were obtained for all patients. In 1 patient a polypoid non-enhancing structure was noted on the iodine map, and conventional colonoscopy revealed impacted stool. Enhancing rectal cancer in 1 patient was correctly shown on the iodine map. Iodine maps helped to differentiate stool fragments/retained fluid by the absence of enhancement when compared to prone CT images. The major advantage of DE colonoscopy was the lack of misregistration. Conclusion: DE MDCT colonoscopy is technically feasible and may obviate the need for unenhanced prone images. It may be possible to perform noncathartic DECT colonoscopy. The major limitation is the limited FOV of tube B. The dose should be optimized to reduce streak artifacts in the pelvic region. (orig.)

  14. Virtual reality in surgical training.

    Science.gov (United States)

    Lange, T; Indelicato, D J; Rosen, J M

    2000-01-01

    Virtual reality in surgery and, more specifically, in surgical training, faces a number of challenges in the future. These challenges are building realistic models of the human body, creating interface tools to view, hear, touch, feel, and manipulate these human body models, and integrating virtual reality systems into medical education and treatment. A final system would encompass simulators specifically for surgery, performance machines, telemedicine, and telesurgery. Each of these areas will need significant improvement for virtual reality to impact medicine successfully in the next century. This article gives an overview of, and the challenges faced by, current systems in the fast-changing field of virtual reality technology, and provides a set of specific milestones for a truly realistic virtual human body.

  15. Virtual School Counseling

    Science.gov (United States)

    Osborn, Debra S.; Peterson, Gary W.; Hale, Rebecca R.

    2015-01-01

    The advent of virtual schools opens doors to opportunity for delivery of student services via the Internet. Through the use of structured interviews with four practicing Florida virtual school counselors, and a follow-up survey, the authors examined the experiences and reflections of school counselors who are employed full time in a statewide…

  16. Analisis Gameplay Game Genre Virtual Pet

    Directory of Open Access Journals (Sweden)

    Abi Senoprabowo

    2015-02-01

    Full Text Available Game adalah struktur interaktif yang membuat pemain berjuang menuju sebuah tujuan. Game dapat memberikan emosi dan mood, menghubungkan dengan orang latihan, sarana latihan, serta dapat memberikan edukasi. Salah satu game yang berkembang saat ini adalah game bergenre Virtual pet. Game virtual pet merupakan game simulasi memelihara sesuatu. Virtual pet memiliki gameplay yang menarik dan menyenangkan yang membuat pemain seolah-olah benar-benar memiliki binatang peliharaan mereka sendiri. Virtual pet dianggap oleh sebagian besar penggunanya dapat memberikan kegembiraan serta rasa kasih sayang karena tingkat interaksinya yang baik. Banyak pengembang game pemula yang mengembangkan genre ini sebagai game yang mereka buat karena kemudahaan dan tingkat penggunanya yang banyak. Akan tetapi banyak dari pengembang game pemula tidak memperhatikan tingkat keberlanjutan game virtual pet yang mereka buat sehingga membuat pemain cepat bosan. Pada penelitian ini, analisis game bergenre virtual pet yang sudah sukses dibuat seperti Zombigotchi, Tamagotchi Unicorn, dan Bird Land, diharapkan dapat membantu para pengembang game pemula agar mengetahui cara merancang dan mengembangkan game virtual pet dengan baik. Kata Kunci: game, gameplay, virtual pet

  17. Estimation of sex and age of 'virtual skeletons'-a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Grabherr, Silke [University Hospital of Lausanne, Institute of Forensic Medicine, Lausanne (Switzerland)]|[University of Bern, Institute of Forensic Medicine, Bern (Switzerland)]|[University Hospital of Lausanne, Service of Diagnostic and Interventional Radiology, Lausanne (Switzerland); Cooper, Christine; Ulrich-Bochsler, Susi [University of Bern, Institute for the History of Medicine, Historical Anthropology, Bern (Switzerland); Uldin, Tanya [Service of Osteo-Archaeology, Aesch (Switzerland); Ross, Steffen; Oesterhelweg, Lars; Bolliger, Stephan; Thali, Michael J. [University of Bern, Institute of Forensic Medicine, Bern (Switzerland); Christe, Andreas [University of Bern, Institute of Forensic Medicine, Bern (Switzerland)]|[University of Bern, Institute of Diagnostic Radiology, Bern (Switzerland); Schnyder, Pierre [University Hospital of Lausanne, Service of Diagnostic and Interventional Radiology, Lausanne (Switzerland); Mangin, Patrice [University Hospital of Lausanne, Institute of Forensic Medicine, Lausanne (Switzerland)

    2009-02-15

    This article presents a feasibility study with the objective of investigating the potential of multi-detector computed tomography (MDCT) to estimate the bone age and sex of deceased persons. To obtain virtual skeletons, the bodies of 22 deceased persons with known age at death were scanned by MDCT using a special protocol that consisted of high-resolution imaging of the skull, shoulder girdle (including the upper half of the humeri), the symphysis pubis and the upper halves of the femora. Bone and soft-tissue reconstructions were performed in two and three dimensions. The resulting data were investigated by three anthropologists with different professional experience. Sex was determined by investigating three-dimensional models of the skull and pelvis. As a basic orientation for the age estimation, the complex method according to Nemeskeri and co-workers was applied. The final estimation was effected using additional parameters like the state of dentition, degeneration of the spine, etc., which where chosen individually by the three observers according to their experience. The results of the study show that the estimation of sex and age is possible by the use of MDCT. Virtual skeletons present an ideal collection for anthropological studies, because they are obtained in a non-invasive way and can be investigated ad infinitum. (orig.)

  18. Ethnography in a Virtual World

    Science.gov (United States)

    Shumar, Wesley; Madison, Nora

    2013-01-01

    This article situates the discussion of virtual ethnography within the larger political/economic changes of twenty-first century consumer capitalism and suggests that increasingly our entire social world is a virtual world and that there were very particular utopian and dystopian framings of virtual community growing out of that history. The…

  19. Single photon emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-09-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) imaging technique. Content: 1 - Introduction: anatomic, functional and molecular imaging; Principle and role of functional or molecular imaging; 2 - Radiotracers: chemical and physical constraints, main emitters, radioisotopes production, emitters type and imaging techniques; 3 - Single photon emission computed tomography: gamma cameras and their components, gamma camera specifications, planar single photon imaging characteristics, gamma camera and tomography; 4 - Quantification in single photon emission tomography: attenuation, scattering, un-stationary spatial resolution, partial volume effect, movements, others; 5 - Synthesis and conclusion

  20. Virtual superheroes: using superpowers in virtual reality to encourage prosocial behavior.

    Directory of Open Access Journals (Sweden)

    Robin S Rosenberg

    Full Text Available BACKGROUND: Recent studies have shown that playing prosocial video games leads to greater subsequent prosocial behavior in the real world. However, immersive virtual reality allows people to occupy avatars that are different from them in a perceptually realistic manner. We examine how occupying an avatar with the superhero ability to fly increases helping behavior. PRINCIPAL FINDINGS: Using a two-by-two design, participants were either given the power of flight (their arm movements were tracked to control their flight akin to Superman's flying ability or rode as a passenger in a helicopter, and were assigned one of two tasks, either to help find a missing diabetic child in need of insulin or to tour a virtual city. Participants in the "super-flight" conditions helped the experimenter pick up spilled pens after their virtual experience significantly more than those who were virtual passengers in a helicopter. CONCLUSION: The results indicate that having the "superpower" of flight leads to greater helping behavior in the real world, regardless of how participants used that power. A possible mechanism for this result is that having the power of flight primed concepts and prototypes associated with superheroes (e.g., Superman. This research illustrates the potential of using experiences in virtual reality technology to increase prosocial behavior in the physical world.