WorldWideScience

Sample records for tomography estudo experimental

  1. Towards experimental quantum-field tomography with ultracold atoms.

    Science.gov (United States)

    Steffens, A; Friesdorf, M; Langen, T; Rauer, B; Schweigler, T; Hübener, R; Schmiedmayer, J; Riofrío, C A; Eisert, J

    2015-07-03

    The experimental realization of large-scale many-body systems in atomic-optical architectures has seen immense progress in recent years, rendering full tomography tools for state identification inefficient, especially for continuous systems. To work with these emerging physical platforms, new technologies for state identification are required. Here we present first steps towards efficient experimental quantum-field tomography. Our procedure is based on the continuous analogues of matrix-product states, ubiquitous in condensed-matter theory. These states naturally incorporate the locality present in realistic physical settings and are thus prime candidates for describing the physics of locally interacting quantum fields. To experimentally demonstrate the power of our procedure, we quench a one-dimensional Bose gas by a transversal split and use our method for a partial quantum-field reconstruction of the far-from-equilibrium states of this system. We expect our technique to play an important role in future studies of continuous quantum many-body systems.

  2. Experimental investigation of liquid chromatography columns by means of computed tomography

    DEFF Research Database (Denmark)

    Astrath, D.U.; Lottes, F.; Vu, Duc Thuong

    2007-01-01

    The efficiency of packed chromatographic columns was investigated experimentally by means of computed tomography (CT) techniques. The measurements were carried out by monitoring tracer fronts in situ inside the chromatographic columns. The experimental results were fitted using the equilibrium di...

  3. Computed tomography and plain radiography in experimental fracture healing

    International Nuclear Information System (INIS)

    Braunstein, E.M.; Goldstein, S.A.; Ku, J.; Smith, P.; Matthews, L.S.

    1986-01-01

    We evaluated the relative contribution of plain radiographs and computed tomography to the assessment of fracture healing under experimental circumstances. In 15 sheep, we performed midshaft femoral osteotomies and internal fixation of the resultant segmental fractures. Radiographs were obtained preoperatively and immediately postoperatively. Animals were sacrificed at 3 weeks, 6 weeks, 12 weeks, 24 weeks, and 36 weeks after surgery, and the femoral specimens radiographed. After removal of the internal fixation devices, computed tomographic scans of the specimens were performed. Computed tomography may be of value in the evaluation of fractures of long bones in those cases in which clinical examination and plain radiographs fail to give adequate information as to the status of healing. (orig./SHA)

  4. Experimental demonstration of selective quantum process tomography on an NMR quantum information processor

    Science.gov (United States)

    Gaikwad, Akshay; Rehal, Diksha; Singh, Amandeep; Arvind, Dorai, Kavita

    2018-02-01

    We present the NMR implementation of a scheme for selective and efficient quantum process tomography without ancilla. We generalize this scheme such that it can be implemented efficiently using only a set of measurements involving product operators. The method allows us to estimate any element of the quantum process matrix to a desired precision, provided a set of quantum states can be prepared efficiently. Our modified technique requires fewer experimental resources as compared to the standard implementation of selective and efficient quantum process tomography, as it exploits the special nature of NMR measurements to allow us to compute specific elements of the process matrix by a restrictive set of subsystem measurements. To demonstrate the efficacy of our scheme, we experimentally tomograph the processes corresponding to "no operation," a controlled-NOT (CNOT), and a controlled-Hadamard gate on a two-qubit NMR quantum information processor, with high fidelities.

  5. Efeitos cerebrais da maconha: resultados dos estudos de neuroimagem Brain effects of cannabis: neuroimaging findings

    Directory of Open Access Journals (Sweden)

    José Alexandre Crippa

    2005-03-01

    Full Text Available A maconha é a droga ilícita mais utilizada. Apesar disto, apenas um pequeno número de estudos investigaram as conseqüências neurotóxicas de longo prazo do uso de cannabis. As técnicas de neuroimagem se constituem em poderosos instrumentos para investigar alterações neuroanatômicas e neurofuncionais e suas correlações clínicas e neuropsicológicas. Uma revisão computadorizada da literatura foi conduzida nos indexadores MEDLINE e PsycLIT entre 1966 e novembro de 2004 com os termos 'cannabis', 'marijuana', 'neuroimaging', 'magnetic resonance', 'computed tomography', 'positron emission tomography', 'single photon emission computed tomography", 'SPET', 'MRI' e 'CT'. Estudos de neuroimagem estrutural apresentam resultados conflitantes, com a maioria dos estudos não relatando atrofia cerebral ou alterações volumétricas regionais. Contudo, há uma pequena evidência de que usuários de longo prazo que iniciaram um uso regular no início da adolescência apresentam atrofia cerebral assim como redução na substância cinzenta. Estudos de neuroimagem funcional relatam aumento na atividade neural em regiões que podem estar relacionadas com intoxicação por cannabis e alteração do humor (lobos frontais mesial e orbital e redução na atividade de regiões relacionadas com funções cognitivas prejudicadas durante a intoxicação aguda. A questão crucial se efeitos neurotóxicos residuais ocorrem após o uso prolongado e regular de maconha permanece obscura, não existindo até então estudo endereçando esta questão diretamente. Estudos de neuroimagem com melhores desenhos, combinados com avaliação cognitiva, podem ser elucidativos neste aspecto.Cannabis is the most widely used illicit drug. Despite this, only a small number of studies have investigated the long-term neurotoxic consequences of cannabis use. Structural and functional neuroimaging techniques are powerful research tools to investigate possible cannabis

  6. Sensitivity Measurement of Transmission Computer Tomography: thePreliminary Experimental Study

    International Nuclear Information System (INIS)

    Widodo, Chomsin-S; Sudjatmoko; Kusminarto; Agung-BS Utomo; Suparta, Gede B

    2000-01-01

    This paper reports result of preliminary experimental study onmeasurement method for sensitivity of a computed tomography (CT) scanner. ACT scanner has been build at the Department of Physics, FMIPA UGM and itsperformance based on its sensitivity was measured. The result showed that themeasurement method for sensitivity confirmed this method may be developedfurther as a measurement standard. Although the CT scanner developed has anumber of shortcoming, the analytical results from the sensitivitymeasurement suggest a number of reparations and improvements for the systemso that improved reconstructed CT images can be obtained. (author)

  7. Turbocharging Quantum Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Gamble, John King [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Nielsen, Erik [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Maunz, Peter Lukas Wilhelm [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Scholten, Travis L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Rudinger, Kenneth Michael [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography suffers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. We describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more effectively detect and characterize quantum noise using carefully tailored ensembles of input states.

  8. Um estudo experimental do processamento de metáforas do português brasileiro / An experimental study on Brazilian Portuguese metaphor processing

    Directory of Open Access Journals (Sweden)

    Antonio João Carvalho Ribeiro

    2017-06-01

    Full Text Available Um estudo experimental do processamento psicolinguístico de metáforas nominais do português brasileiro (X é um Y, p. ex., “Irene é um furacão”, foi realizado com o objetivo de evidenciar, a partir de tempos de leitura (RTs, a compreensão de expressões familiares, high-apt (“bem construídas” e cujo veículo se acha convencionalizado. Na primeira fase da pesquisa, realizaram-se dois norming studies (“estudos normativos” com vistas ao ranqueamento de metáforas nominais (p. ex. “Algumas mulheres são furacões” em relação a familiaridade, aptness (“adequação” e convencionalidade. Na segunda fase da pesquisa, um experimento de leitura automonitorada (self-paced, non-cumulative, moving-window reading foi conduzido, recorrendo, para a composição dos estímulos, às metáforas, p. ex., “Irene é um furacão”, que alcançaram, nos estudos normativos da primeira fase, ratings (ou “classificações” de “muito familiares”, “very high-apt’’ e “altamente convencionalizadas”. Evidências do português brasileiro em favor do processamento direto de metáforas foram obtidas, conforme preconiza o modelo de Class-inclusion, de Glucksberg e Keysar (1990, pois não se revelaram diferenças significativas entre os RTs médios nas três condições: “metáfora”, “literal” e “declaração literal de inclusão em classe”, em contraposição aos achados de Janus e Bever (1985, que observaram tempos de leitura de metáforas novas significativamente maiores do que os de expressões literais, conforme as predições do Modelo Pragmático Padrão de processamento indireto.

  9. An elegant technique for ex vivo imaging in experimental research—Optical coherence tomography (OCT)

    DEFF Research Database (Denmark)

    Tschernig, T.; Thrane, Lars; Jørgensen, Thomas Martini

    2013-01-01

    Optical coherence tomography (OCT) is an elegant technology for imaging of tissues and organs and has been established for clinical use for around a decade. Thus, it is used in vivo but can also serve as a valuable ex vivo imaging tool in experimental research. Here, a brief overview is given...

  10. Fundamental steps in experimental design for animal studies Passos fundamentais em desenhos experimentais de estudos envolvendo animais

    Directory of Open Access Journals (Sweden)

    José Eduardo de Aguilar-Nascimento

    2005-02-01

    Full Text Available Animal studies continue to have a vital role in science development. The aim of this review is to provide to new investigators an overview of the important steps involved in experimental designs and also to suggest some practical information that is commonly associated with this process. Investigators should adhere to the ethical procedure and follow strictly the scientific method. Both the aims and well-formulated hypothesis are essential and practical. In this regard a profound literature search and the aid of an experienced statistician is encouraged. The need of randomization, blinding, and attempting to minimize variation is discussed and recommended. The choosing of good control groups and the employment of pilot studies are useful. Finally, the formulation of new questions to be further responded is expected.Estudos em animais continuam a ser vital para o desenvolvimento da ciência. O objetivo dessa revisão é o de apresentar a novos pesquisadores, uma visão geral dos passos importantes envolvidos no desenho experimental e, ao mesmo tempo, sugerir algumas informações de ordem prática que geralmente estão incluídas no processo da pesquisa. Os pesquisadores devem atentar sempre aos princípios éticos e seguir estritamente o método científico. Hipóteses bem formuladas e objetivas claros são essenciais e práticos. Nesse contexto, uma pesquisa bibliográfica profunda deve ser executada previamente e o pesquisador deve contar, se possível, com o auxilio de um estatístico experiente. A necessidade de randomização, de planejar um estudo cego e de se minimizar a variação são discutidas e enfatizadas. A escolha de bons grupos controles e o emprego de um estudo piloto são recomendados. Finalmente, a formulação de novas questões para serem respondidas por novas pesquisas é esperada.

  11. Experimental investigation of the diffusion coefficients in porous media by application of X-ray computer tomography

    DEFF Research Database (Denmark)

    Zhelezny, Petr; Shapiro, Alexander

    2006-01-01

    The present work describes a new experimental method that makes it possible to investigate diffusion coefficients in a porous medium. The method is based on application of X-ray computed tomography (CT). The general applicability of this method for the determination of diffusion coefficients...

  12. Instalação de uma pequena bacia experimental florestal: estudo de caso da bacia do Rio Araponga

    Directory of Open Access Journals (Sweden)

    Aline de Almeida Mota

    Full Text Available RESUMO O presente trabalho detalha aspectos importantes a serem observados nos procedimentos de seleção e caracterização de uma bacia experimental florestal e instalação de um sistema de monitoramento hidrológico, com enfoque em fluviometria, pluviometria e tensiometria. Para tanto, utilizou-se a experiência adquirida no estudo de caso da bacia experimental do Rio Araponga (ARA, localizada no município de Rio Negrinho (SC. O levantamento dos pontos de nascentes e confluências permitiu a extração da rede de drenagem mais próxima da realidade considerando a base cartográfica disponível (escala 1:10.000. A determinação dos locais adequados dos aparelhos de monitoramento hidrológico foi possível somente com levantamento topográfico mais detalhado (escala 1:5.000.

  13. Instalação de uma pequena bacia experimental florestal: estudo de caso da bacia do Rio Araponga

    Directory of Open Access Journals (Sweden)

    Aline de Almeida Mota

    2016-10-01

    Full Text Available RESUMO O presente trabalho detalha aspectos importantes a serem observados nos procedimentos de seleção e caracterização de uma bacia experimental florestal e instalação de um sistema de monitoramento hidrológico, com enfoque em fluviometria, pluviometria e tensiometria. Para tanto, utilizou-se a experiência adquirida no estudo de caso da bacia experimental do Rio Araponga (ARA, localizada no município de Rio Negrinho (SC. O levantamento dos pontos de nascentes e confluências permitiu a extração da rede de drenagem mais próxima da realidade considerando a base cartográfica disponível (escala 1:10.000. A determinação dos locais adequados dos aparelhos de monitoramento hidrológico foi possível somente com levantamento topográfico mais detalhado (escala 1:5.000.

  14. Sparsity reconstruction in electrical impedance tomography: An experimental evaluation

    KAUST Repository

    Gehre, Matthias

    2012-02-01

    We investigate the potential of sparsity constraints in the electrical impedance tomography (EIT) inverse problem of inferring the distributed conductivity based on boundary potential measurements. In sparsity reconstruction, inhomogeneities of the conductivity are a priori assumed to be sparse with respect to a certain basis. This prior information is incorporated into a Tikhonov-type functional by including a sparsity-promoting ℓ1-penalty term. The functional is minimized with an iterative soft shrinkage-type algorithm. In this paper, the feasibility of the sparsity reconstruction approach is evaluated by experimental data from water tank measurements. The reconstructions are computed both with sparsity constraints and with a more conventional smoothness regularization approach. The results verify that the adoption of ℓ1-type constraints can enhance the quality of EIT reconstructions: in most of the test cases the reconstructions with sparsity constraints are both qualitatively and quantitatively more feasible than that with the smoothness constraint. © 2011 Elsevier B.V. All rights reserved.

  15. Experimental design optimisation: theory and application to estimation of receptor model parameters using dynamic positron emission tomography

    International Nuclear Information System (INIS)

    Delforge, J.; Syrota, A.; Mazoyer, B.M.

    1989-01-01

    General framework and various criteria for experimental design optimisation are presented. The methodology is applied to estimation of receptor-ligand reaction model parameters with dynamic positron emission tomography data. The possibility of improving parameter estimation using a new experimental design combining an injection of the β + -labelled ligand and an injection of the cold ligand is investigated. Numerical simulations predict remarkable improvement in the accuracy of parameter estimates with this new experimental design and particularly the possibility of separate estimations of the association constant (k +1 ) and of receptor density (B' max ) in a single experiment. Simulation predictions are validated using experimental PET data in which parameter uncertainties are reduced by factors ranging from 17 to 1000. (author)

  16. 18 F-Fluoride positron emission tomography/computed tomography for noninvasive in vivo quantification of pathophysiological bone metabolism in experimental murine arthritis

    Science.gov (United States)

    2014-01-01

    Introduction Evaluation of disease severity in experimental models of rheumatoid arthritis is inevitably associated with assessment of structural bone damage. A noninvasive imaging technology allowing objective quantification of pathophysiological alterations of bone structure in rodents could substantially extend the methods used to date in preclinical arthritis research for staging of autoimmune disease severity or efficacy of therapeutical intervention. Sodium 18 F-fluoride (18 F-NaF) is a bone-seeking tracer well-suited for molecular imaging. Therefore, we systematically examined the use of 18 F-NaF positron emission tomography/computed tomography (PET/CT) in mice with glucose-6-phosphate isomerase (G6PI)–induced arthritis for quantification of pathological bone metabolism. Methods F-fluoride was injected into mice before disease onset and at various time points of progressing experimental arthritis. Radioisotope accumulation in joints in the fore- and hindpaws was analyzed by PET measurements. For validation of bone metabolism quantified by 18 F-fluoride PET, bone surface parameters of high-resolution μCT measurements were used. Results Before clinical arthritis onset, no distinct accumulation of 18 F-fluoride was detectable in the fore- and hindlimbs of mice immunized with G6PI. In the course of experimental autoimmune disease, 18 F-fluoride bone uptake was increased at sites of enhanced bone metabolism caused by pathophysiological processes of autoimmune disease. Moreover, 18 F-fluoride signaling at different stages of G6PI-induced arthritis was significantly correlated with the degree of bone destruction. CT enabled identification of exact localization of 18 F-fluoride signaling in bone and soft tissue. Conclusions The results of this study suggest that small-animal PET/CT using 18 F-fluoride as a tracer is a feasible method for quantitative assessment of pathophysiological bone metabolism in experimental arthritis. Furthermore, the

  17. Estudo teórico-experimental da contribuição da armadura para a capacidade resistente de vigas parcialmente revestidas

    OpenAIRE

    Leandro de Amorim Cavalcanti

    2010-01-01

    Este trabalho tem por objetivo investigar a contribuição da armadura para a capacidade resistente de vigas mistas parcialmente revestidas, bem como sua eficiência para promover o comportamento conjunto aço-concreto, imprescindível para a obtenção de vigas mistas. O estudo engloba uma investigação experimental com ensaios de vigas sob flexão em quatro pontos e uma simulação numérica utilizando o pacote computacional DIANA®, visando obter dados do comportamento de vigas mistas parcialmente reve...

  18. Experimental Results of Guided Wave Travel Time Tomography

    Science.gov (United States)

    Volker, Arno; Mast, Arjan; Bloom, Joost

    2010-02-01

    Corrosion is one of the industries major issues regarding the integrity of assets. Currently inspections are conducted at regular intervals to ensure a sufficient integrity level of these assets. Both economical and social requirements are pushing the industry to even higher levels of availability, reliability and safety of installations. The concept of predictive maintenance using permanent sensors that monitor the integrity of an installation is an interesting addition to the current method of periodic inspections reducing uncertainty and extending inspection intervals. Guided wave travel time tomography is a promising method to monitor the wall thickness quantitatively over large areas. Obviously the robustness and reliability of such a monitoring system is of paramount importance. Laboratory experiments have been carried out on a 10″ pipe with a nominal wall thickness of 8 mm. Multiple, inline defects have been created with a realistic morphology. The depth of the defects was increased stepwise from 0.5 mm to 2 mm. Additionally the influences of the presence of liquid inside the pipe and surface roughness have been evaluated as well. Experimental results show that this method is capable of providing quantitative wall thickness information over a distance of 4 meter, with a sufficient accuracy such that results can be used for trending. The method has no problems imaging multiple defects.

  19. Mosaico da linguagem das crianças bilíngues bimodais: estudos experimentais

    Directory of Open Access Journals (Sweden)

    Ronice Müller de Quadros

    2016-03-01

    Full Text Available Resumo: O presente trabalho apresenta a metodologia utilizada no estudo experimental que investiga o desenvolvimento bilíngue bimodal de crianças surdas com implante coclear (IC e crianças ouvintes filhas de pais surdos (Kodas2, com faixa etária entre 4 e 8 anos. Além desses dois grupos de crianças, participaram da pesquisa crianças surdas filhas de pais surdos ou filhas de pais ouvintes, e adultos ouvintes filhos de pais surdos, com o intuito de constituírem os grupos de controle. Inicialmente, descrevemos o estudo experimental desenvolvido e apresentamos como organizamos as feiras para coleta de dados. E, em seguida, apresentamos os testes utilizados no estudo, que contemplam os aspectos linguísticos da Língua de Sinais Brasileira (Libras e do Português Brasileiro (PB e formam o mosaico da linguagem dessas crianças. Concluímos com os resultados gerais das investigações realizadas até o momento.

  20. Estudo de ligações em estruturas mistas de concreto-madeira

    OpenAIRE

    Elias Antonio Nicolas

    2001-01-01

    Resumo: Esta pesquisa se refere ao estudo do comportamento mecânico de conectores empregados em estruturas mistas de concreto e madeira, estruturas estas normalmente utilizadas em construções civis tais como pontes, pisos e coberturas residenciais. Neste sentido, foi realizado um estudo teórico-experimental sobre os conectores onde se determinou o valor do módulo de deslizamento (K) através de curvas cargas x deslizamentos obtidas a partir ensaios de laboratório. Os corpos-de-prova foram mold...

  1. Estudo da transmigração bacteriana na apendicite experimental em coelhos A study about bacterial transmigration in experimental Appendicitis in rabbits

    Directory of Open Access Journals (Sweden)

    ECF RAMOS

    2000-01-01

    Full Text Available Introdução: A queda extrínseca dos mecanismos de defesa de um hospedeiro é vista classicamente como uma infecção, que resulta na aquisição de um tecido normal, de um novo microorganismo, cuja virulência é fundamental para a sua patogenia.Na década de 50, estudos comprovaram que bactérias e endotoxinas podem ultrapassar a barreira intestinal e atingir a circulação, demonstrando ainda, que a flora intestinal representa uma importante fonte para o desenvolvimento da infecção sistêmica. Objetivo: o presente estudo visa avaliar a ocorrência de transmigração bacteriana em apendicite experimental induzida em coelhos, mediante a oclusão completa do apêndice vermiforme. Métodos: foram utilizados 24 coelhos brancos, da linhagem Nova Zelândia, com peso corporal variando de 2500 a 3000 gramas, sendo então divididos em 2 grupos. Os animais do Grupo I foram submetidos a laparotomia mediana e retirada de fragmentos do baço, rim esquerdo, pulmão direito, linfonodo abdominal, conteúdo da luz do apêndice vermiforme e sangue da veia porta para cultura. Os animais do Grupo II foram submetidos a laparotomia mediana e oclusão completa do apêndice vermiforme para a indução de apendicite e, após 24 horas, realizada a coleta do material nos moldes do Grupo I. Resultados: No Grupo controle (Grupo I, não se observou o crescimento de bactérias nas amostras analisadas. No Grupo experimento (Grupo II, observou-se o crescimento de Escherichia coli em todos os animais. Conclusão: Ocorreu transmigração bacteriana após 24 horas de observação em coelhos com apendicite experimental.The present study aims to evaluate the occurrence of the bacterial transmigration in induced ezxperimental appendicitis in rabbitis through complete oclusion of the vermiform appendix. 24 New Zealand white rabbits with a body weight ranging from 2500 to 3000 grams were used. They were divided into 2 groups. The animals from group I were submitted to a median

  2. Experimental study of mechanisms of sand production using X-ray computerized tomography; Estudo experimental dos mecanismos da producao de areia empregando tomografia computadorizada de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Janaina B.; Vargas Junior, Euripedes [Pontificia Univ. Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. de Engenharia Civil; Barroso, Emilio V. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Geologia; Campos, Elisabete; Goncalves, Clemente; Tavares, Andre [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES)

    2004-07-01

    During productive phase of the well, many times there is simultaneous production of the solid particles detached from matrix of the reservoir rock. This phenomenon receives the name of the sand production. In this case stress and flow conditions around of the well are fundamental factors for deflagration of the process. Stress concentration in the wall of the well lead to the loss of cohesion between grains arising, consequently, a granular material region susceptible for dragging by seepage forces derived from fluid flow. The objective of this work was to perform sand production tests in Rio Bonito and synthetic sandstone samples using real-time X-Ray Computerized Tomography. The tests investigated the initial and the evolution of failure at the cavity wall of samples. These are initial stages of the sand production process. The analysis of the CT-scans obtained during tests allowed the visualization of breakouts and collapses of the wells. From studies more details were possible estimate the sand production and produce 3-D images of the propagation of the failure. (author)

  3. Atividade Experimental como Proposta de Formação de Aprendizagem Significativa no Tópico de Estudo de Soluções no Ensino Médio

    Directory of Open Access Journals (Sweden)

    Francisco Alberto Saraiva

    2017-05-01

    Full Text Available Como parte da dissertação em Ensino de Ciências e Matemática (ECM, o presente artigo investiga especificamente, indícios de Aprendizagem Significativa (AS no ensino e aprendizagem em Química no tópico Estudo de Soluções (ES adotando Atividade Experimental (AE. Para coleta de dados, foram aplicadas questões após as aulas teóricas e atividade experimental a estudantes do 2° ano do Ensino Médio de uma escola pública do Ceará. A análise dos dados leva a concluir que a AE, na abordagem do tópico de ES, contribui para aprendizagem significativa, pois os estudantes apresentaram evolução em suas respostas.

  4. Estudo experimental dos efeitos da heparina de baixo peso molecular (Enoxaparina na formação de calo ósseo em fêmures de ratos The effects of low-molecular-weight heparin (Enoxaparin on bony callus formation in rats' femurs - an experimental study

    Directory of Open Access Journals (Sweden)

    Salim Mussi Filho

    2006-01-01

    Full Text Available O tromboembolismo venoso é uma complicação grave que pode ocorrer após fraturas. O tratamento anticoagulante mais utilizado é com a heparina de baixo peso molecular (HBPM. Existem estudos que mostram que essa droga pode interferir no metabolismo ósseo. Com o objetivo de avaliar a influência da HBPM no processo de formação de calo ósseo, realizamos um estudo experimental em ratos. A amostra constituiu-se de 22 ratos de linhagem Wistar, machos, que foram submetidos à fratura diafisária de seus fêmures direitos. Foram divididos em dois grupos de 11. No grupo controle, os animais recebiam soro fisiológico e no grupo de estudo, recebiam HBPM, enoxaparina, diariamente, por 28 dias. Após este período os ratos foram submetidos à eutanásia e os fêmures foram avaliados. No estudo macroscópico foi constatada consolidação em 11 animais (100% que não receberam enoxaparina, e, em dez animais (90,9% que receberam a droga em estudo. No estudo histológico foi constatada a formação de calo ósseo em todos os fêmures. Concluiu-se neste experimento que a enoxaparina não altera o processo de consolidação óssea em fêmures de ratos Wistar.Venous thromboembolism is a serious complication that may follow fractures. The most commonly used anticoagulant treatment is low-molecular-weight heparin (LMWH. There are some studies showing that this drug may interfere on bone metabolism. With the objective of evaluating the LMWH influence on the process of bony callus formation, we conducted an experimental study on rats. Sample was constituted of 22 Wistar male rats, which were submitted to diaphyseal fracture on their right femurs. They were divided into two groups of 11 subjects each. In the control group, the animals received saline solution and in the study group, they received LMWH - enoxaparin - in a daily basis, during 28 days. After that period, the rats were submitted to euthanasia for femur assessment purposes. At the macroscopic study

  5. Estudo Experimental e Numérico de Tensões Residuais em Juntas Soldadas com e sem Restrição

    Directory of Open Access Journals (Sweden)

    Daniel Casassola Gonçalves

    Full Text Available Resumo O conhecimento das tensões residuais geradas nos processos de soldagem apresenta especial importância no desempenho das estruturas e componentes soldados, pois durante a vida em serviço eles estarão sujeitos a diferentes níveis de carregamentos, que associados aos campos de tensões residuais pré-existentes podem levar à ruptura inesperada. Neste contexto, o presente trabalho tem como objetivo estudar o nível das tensões residuais geradas em juntas soldadas, pelo processo arame tubular (FCAW - Flux Cored Arc Welding, de aço ASTM A 131 Grau A, usadas na construção naval, por difração de raios-X, usando a técnica do sen2ψ. Foi realizado um estudo comparativo das mudanças nos campos de tensões quando adotadas restrições para manter a geometria de projeto da junta, bem como uma análise numérica computacional pelo método de elementos finitos, com os resultados obtidos pelo método experimental. A maioria dos resultados das tensões residuais mostrou que houve similaridade qualitativa, na sua natureza, entre o modelo e os experimentos nas regiões da zona termicamente afetada e do metal de solda. As análises de microdureza Vickers e a caracterização microestrutural por microscopia óptica das juntas soldadas complementaram o presente estudo.

  6. Experimental measurement of oil–water two-phase flow by data fusion of electrical tomography sensors and venturi tube

    International Nuclear Information System (INIS)

    Liu, Yinyan; Deng, Yuchi; Zhang, Maomao; Yu, Peining; Li, Yi

    2017-01-01

    Oil–water two-phase flows are commonly found in the production processes of the petroleum industry. Accurate online measurement of flow rates is crucial to ensure the safety and efficiency of oil exploration and production. A research team from Tsinghua University has developed an experimental apparatus for multiphase flow measurement based on an electrical capacitance tomography (ECT) sensor, an electrical resistance tomography (ERT) sensor, and a venturi tube. This work presents the phase fraction and flow rate measurements of oil–water two-phase flows based on the developed apparatus. Full-range phase fraction can be obtained by the combination of the ECT sensor and the ERT sensor. By data fusion of differential pressures measured by venturi tube and the phase fraction, the total flow rate and single-phase flow rate can be calculated. Dynamic experiments were conducted on the multiphase flow loop in horizontal and vertical pipelines and at various flow rates. (paper)

  7. Experimental Study on GFRP Surface Cracks Detection Using Truncated-Correlation Photothermal Coherence Tomography

    Science.gov (United States)

    Wang, Fei; Liu, Junyan; Mohummad, Oliullah; Wang, Yang

    2018-04-01

    In this paper, truncated-correlation photothermal coherence tomography (TC-PCT) was used as a nondestructive inspection technique to evaluate glass-fiber reinforced polymer (GFRP) composite surface cracks. Chirped-pulsed signal that combines linear frequency modulation and pulse excitation was proposed as an excitation signal to detect GFRP composite surface cracks. The basic principle of TC-PCT and extraction algorithm of the thermal wave signal feature was described. The comparison experiments between lock-in thermography, thermal wave radar imaging and chirped-pulsed photothermal radar for detecting GFRP artificial surface cracks were carried out. Experimental results illustrated that chirped-pulsed photothermal radar has the merits of high signal-to-noise ratio in detecting GFRP composite surface cracks. TC-PCT as a depth-resolved photothermal imaging modality was employed to enable three-dimensional visualization of GFRP composite surface cracks. The results showed that TC-PCT can effectively evaluate the cracks depth of GFRP composite.

  8. Energy-resolved computed tomography: first experimental results

    International Nuclear Information System (INIS)

    Shikhaliev, Polad M

    2008-01-01

    First experimental results with energy-resolved computed tomography (CT) are reported. The contrast-to-noise ratio (CNR) in CT has been improved with x-ray energy weighting for the first time. Further, x-ray energy weighting improved the CNR in material decomposition CT when applied to CT projections prior to dual-energy subtraction. The existing CT systems use an energy (charge) integrating x-ray detector that provides a signal proportional to the energy of the x-ray photon. Thus, the x-ray photons with lower energies are scored less than those with higher energies. This underestimates contribution of lower energy photons that would provide higher contrast. The highest CNR can be achieved if the x-ray photons are scored by a factor that would increase as the x-ray energy decreases. This could be performed by detecting each x-ray photon separately and measuring its energy. The energy selective CT data could then be saved, and any weighting factor could be applied digitally to a detected x-ray photon. The CT system includes a photon counting detector with linear arrays of pixels made from cadmium zinc telluride (CZT) semiconductor. A cylindrical phantom with 10.2 cm diameter made from tissue-equivalent material was used for CT imaging. The phantom included contrast elements representing calcifications, iodine, adipose and glandular tissue. The x-ray tube voltage was 120 kVp. The energy selective CT data were acquired, and used to generate energy-weighted and material-selective CT images. The energy-weighted and material decomposition CT images were generated using a single CT scan at a fixed x-ray tube voltage. For material decomposition the x-ray spectrum was digitally spilt into low- and high-energy parts and dual-energy subtraction was applied. The x-ray energy weighting resulted in CNR improvement of calcifications and iodine by a factor of 1.40 and 1.63, respectively, as compared to conventional charge integrating CT. The x-ray energy weighting was also applied

  9. Reconstruction of an InAs nanowire using geometric tomography

    DEFF Research Database (Denmark)

    Pennington, Robert S.; König, Stefan; Alpers, Andreas

    Geometric tomography and conventional algebraic tomography algorithms are used to reconstruct cross-sections of an InAs nanowire from a tilt series of experimental annular dark-field images. Both algorithms are also applied to a test object to assess what factors affect the reconstruction quality....... When using the present algorithms, geometric tomography is faster, but artifacts in the reconstruction may be difficult to recognize....

  10. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  11. Optimal experiment design for quantum state tomography: Fair, precise, and minimal tomography

    International Nuclear Information System (INIS)

    Nunn, J.; Smith, B. J.; Puentes, G.; Walmsley, I. A.; Lundeen, J. S.

    2010-01-01

    Given an experimental setup and a fixed number of measurements, how should one take data to optimally reconstruct the state of a quantum system? The problem of optimal experiment design (OED) for quantum state tomography was first broached by Kosut et al.[R. Kosut, I. Walmsley, and H. Rabitz, e-print arXiv:quant-ph/0411093 (2004)]. Here we provide efficient numerical algorithms for finding the optimal design, and analytic results for the case of 'minimal tomography'. We also introduce the average OED, which is independent of the state to be reconstructed, and the optimal design for tomography (ODT), which minimizes tomographic bias. Monte Carlo simulations confirm the utility of our results for qubits. Finally, we adapt our approach to deal with constrained techniques such as maximum-likelihood estimation. We find that these are less amenable to optimization than cruder reconstruction methods, such as linear inversion.

  12. Cardiac positron tomography

    International Nuclear Information System (INIS)

    Geltmann, E.M.; Roberts, R.; Sobel, B.E.

    1980-01-01

    Positron emission tomography (PET) performed after the administration of the positron-emitting radionuclides carbon-11 ( 11 C), nitrogen-13 ( 13 N), oxygen-15 ( 15 O) and fluorine-18 ( 18 F) has permitted the improved noninvasive assessment of the regional myocardial metabolism of normal physiologic substrates and intermediates and their cogeners. In experimental animals, the rate of oxidation of 11 C-palmitate correlates closely with other indexes of oxygen consumption, and the extraction of 11 C-palmitate (like that of 18 F-fatty acids and 18 F-fluoredoxyglucose) ist markedly diminished in regions of myocardial ischemia. In both experimental animals and in patients, myocardial infarct site and size, determined by positron emission tomography after the intravenous injection of 11 C-palmitate, correlate closely with the electrocardiographic infarct locus and enzymatically estimated infarct size as well as with the location and extent of regional left ventricular wall motion abnormalities. PET offers promise for assessment of flow as well despite the complexities involved. PET with 13 NH 3 appears to provide one useful qualitative index, although this tracer ist actively metabolized. Because of the quantitative capabilities of positron emission tomography and the rapid progress which is being made in the development of fast scan, multi-slice, and gated instrumentation, this technique is likely to facilitate improved understanding and characterization of regional myocardial metabolism and blood flow in man under physiological and pathophysiological conditions. (orig.) [de

  13. The Linearity of Optical Tomography: Sensor Model and Experimental Verification

    Directory of Open Access Journals (Sweden)

    Siti Zarina MOHD. MUJI

    2011-09-01

    Full Text Available The aim of this paper is to show the linearization of optical sensor. Linearity of the sensor response is a must in optical tomography application, which affects the tomogram result. Two types of testing are used namely, testing using voltage parameter and testing with time unit parameter. For the former, the testing is by measuring the voltage when the obstacle is placed between transmitter and receiver. The obstacle diameters are between 0.5 until 3 mm. The latter is also the same testing but the obstacle is bigger than the former which is 59.24 mm and the testing purpose is to measure the time unit spend for the ball when it cut the area of sensing circuit. Both results show a linear relation that proves the optical sensors is suitable for process tomography application.

  14. Estudo do metabolismo da glicose na tuberculose pulmonar ativa utilizando a tomografia por emissão de pósitrons (18F-FDG PET Evaluation of glucose metabolism in active lung tuberculosis by positron-emission tomography (18F-FDG PET

    Directory of Open Access Journals (Sweden)

    SIDNEY BOMBARDA

    2002-09-01

    Full Text Available Os métodos de imagem utilizados na avaliação da tuberculose pulmonar incluem a radiografia e a tomografia computadorizada do tórax. As imagens obtidas pelos métodos de medicina nuclear permitem estudos funcionais e metabólicos dos órgãos de interesse, através do uso de radiofármacos específicos. Alterações do metabolismo da glicose podem ser detectadas pela tomografia por emissão de pósitrons (PET utilizando-se o 18F-fluorodesoxiglicose (18F-FDG. Essas alterações estão presentes nas doenças neoplásicas, inflamatórias e infecciosas. A tuberculose é uma doença granulomatosa causada pelo Mycobacterium tuberculosis, que se utiliza de glicose como fonte de energia. Objetivo: O estudo do metabolismo da glicose na tuberculose pulmonar através da PET e sua comparação com a tomografia computadorizada de tórax. Material e métodos: Foram avaliados 20 pacientes portadores de tuberculose pulmonar. Todos foram submetidos à PET e à tomografia computadorizada de tórax, em até 30 dias após o início do tratamento. Resultados: Todos os pacientes apresentaram captação positiva do 18F-FDG na PET. Na tomografia computadorizada do tórax, todos os pacientes apresentaram sinais compatíveis com atividade de tuberculose. A sensibilidade dos dois métodos foi de 100%. Houve concordância entre os achados do 18F-FDG PET e da tomografia computadorizada (K = 0,27 e p Current methods to evaluate lung tuberculosis include chest radiography and computed tomography. Nuclear medicine imaging techniques are performed after administration of specific radiopharmaceuticals that accumulate in the organs of interest. Alterations of glucose metabolism can be observed by positron-emission tomography, using 18F-fluorodeoxyglucose (18F-FDG PET. These findings are present in the neoplasms, but also in inflammatory and infectious diseases. Tuberculosis is a granulomatous disease caused by Mycobacterium tuberculosis , that uses glucose as an energy source

  15. Estudo experimental e modelagem do crescimento de fungos filamentosos termorresistentes em sucos tropicais

    OpenAIRE

    Cunha, Vanessa Albres Botelho da

    2003-01-01

    Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia de Alimentos. A crescente preocupação da população com a qualidade de vida e com a saúde fez com que houvesse um aumento no consumo de sucos a base de frutas naturais e sem conservantes. Os fungos filamentosos termorresistentes são um dos principais contaminantes de sucos processados termicamente. Estudos sobre a incidência de fungos termorresistentes evidenciam que ...

  16. Evaluation of water content in rock mass by electromagnetic and resistivity tomography. Denjiha, hiteiko tomography ni yoru ganban no gansui jotai hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Inaba, T; Inoue, M; Matsumoto, K [Kajima Corp., Tokyo (Japan)

    1993-10-31

    As a method to evaluate the rock mass, electromagnetic tomography and resistivity tomography were tested on the original site. The electromagnetic tomography can tomographically analyze the propagation velocity and initial amplitude damping. The resistivity tomography uses a finite element method from the initial resistivity distribution model and finally gives a model which is nearly equal to the actual resistivity distribution. Both the above tomographic analyses can detect the crushed spot as a low velocity, high damping and low resistivity spot. However, the electromagnetic tomography could detect finer structure than the resistivity tomography. The water content of rock mass was evaluated from the damping coefficient which was given by the amplitude damping tomography of electromagnetic wave. If it is compared with the water content which is given by the dielectric constant of velocity tomography, there partially exists discrepancy between both, because the damping coefficient contains information on cracks which disperse and reflect the electromagnetic wave. Between the resistivity and porosity, there exists a known experimental formula, which was satisfied by the presently given resistivity. 9 refs., 10 figs.

  17. Organ hierarchy during low blood flow on-pump: a randomized experimental positron emission tomography study

    DEFF Research Database (Denmark)

    Thomassen, Sisse Anette; Kjærgaard, Benedict; Frøkiær, Jørgen

    will be measured with dynamic PET-CT before CPB and during the different blood flows. Systemic oxygen consumption will be estimated by measurement of mixed venous saturation and lactate, and regional muscle oxygen saturation (tSO2) with near infrared spectroscopy at the lower limb. Result: Preliminary data......].The purpose of this animal study is to investigate the organ hierarchy of brain, liver, kidney and muscle at normal and low blood flows by using dynamic positron tomography (PET-CT) during CPB. Methods CPB at different blood flows will be investigated in an experimental model of six 70 kg pigs...... knowledge this is the first study investigating organ hierarchy with dynamic PET-CT during profound systemic ischemia due to suboptimal blood flows during normothermic CPB. References 1. Murphy JM, Hessel II EA, Groom RC. Optimal perfusion during cardiopulmonary bypass: an Evidence-based approach. Anesth...

  18. Reconstruction of an InAs nanowire using geometric and algebraic tomography

    International Nuclear Information System (INIS)

    Pennington, R S; Boothroyd, C B; König, S; Alpers, A; Dunin-Borkowski, R E

    2011-01-01

    Geometric tomography and conventional algebraic tomography algorithms are used to reconstruct cross-sections of an InAs nanowire from a tilt series of experimental annular dark-field images. Both algorithms are also applied to a test object to assess what factors affect the reconstruction quality. When using the present algorithms, geometric tomography is faster, but artifacts in the reconstruction may be difficult to recognize.

  19. Reconstruction of an InAs nanowire using geometric and algebraic tomography

    DEFF Research Database (Denmark)

    Pennington, Robert S.; König, S.; Alpers, A.

    2011-01-01

    Geometric tomography and conventional algebraic tomography algorithms are used to reconstruct cross-sections of an InAs nanowire from a tilt series of experimental annular dark-field images. Both algorithms are also applied to a test object to assess what factors affect the reconstruction quality....... When using the present algorithms, geometric tomography is faster, but artifacts in the reconstruction may be difficult to recognize....

  20. Monte Carlo simulation of gamma ray tomography for image reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Guedes, Karlos A.N.; Moura, Alex; Dantas, Carlos; Melo, Silvio; Lima, Emerson, E-mail: karlosguedes@hotmail.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Meric, Ilker [University of Bergen (Norway)

    2015-07-01

    The Monte Carlo simulations of known density and shape object was validate with Gamma Ray Tomography in static experiments. An aluminum half-moon piece placed inside a steel pipe was the MC simulation test object that was also measured by means of gamma ray transmission. Wall effect of the steel pipe due to irradiation geometry in a single pair source-detector tomography was evaluated by comparison with theoretical data. MCNPX code requires a defined geometry to each photon trajectory which practically prevents this usage for tomography reconstruction simulation. The solution was found by writing a program in Delphi language to create input files automation code. Simulations of tomography data by automated MNCPX code were carried out and validated by experimental data. Working in this sequence the produced data needed a databank to be stored. Experimental setup used a Cesium-137 isotopic radioactive source (7.4 × 109 Bq), and NaI(Tl) scintillation detector of (51 × 51) × 10−3 m crystal size coupled to a multichannel analyzer. A stainless steel tubes of 0,154 m internal diameter, 0.014 m thickness wall. The results show that the MCNPX simulation code adapted to automated input file is useful for generating a matrix data M(θ,t), of a computerized gamma ray tomography for any known density and regular shape object. Experimental validation used RMSE from gamma ray paths and from attenuation coefficient data. (author)

  1. Imaging performance of a hybrid x-ray computed tomography-fluorescence molecular tomography system using priors.

    Science.gov (United States)

    Ale, Angelique; Schulz, Ralf B; Sarantopoulos, Athanasios; Ntziachristos, Vasilis

    2010-05-01

    The performance is studied of two newly introduced and previously suggested methods that incorporate priors into inversion schemes associated with data from a recently developed hybrid x-ray computed tomography and fluorescence molecular tomography system, the latter based on CCD camera photon detection. The unique data set studied attains accurately registered data of high spatially sampled photon fields propagating through tissue along 360 degrees projections. Approaches that incorporate structural prior information were included in the inverse problem by adding a penalty term to the minimization function utilized for image reconstructions. Results were compared as to their performance with simulated and experimental data from a lung inflammation animal model and against the inversions achieved when not using priors. The importance of using priors over stand-alone inversions is also showcased with high spatial sampling simulated and experimental data. The approach of optimal performance in resolving fluorescent biodistribution in small animals is also discussed. Inclusion of prior information from x-ray CT data in the reconstruction of the fluorescence biodistribution leads to improved agreement between the reconstruction and validation images for both simulated and experimental data.

  2. Pathophysiological study of experimental hydrocephalus with computed tomography (CT) scan

    International Nuclear Information System (INIS)

    Murata, Takaho

    1980-01-01

    In order to investigate the pathophysiological changes during a development of hydrocephalus, the observations employing computed tomography (CT) scans and monitorings of intracranial epidural pressure (EDP) were performed in a series of kaolin-induced canine hydrocephalus. According to ''volume index'' of ventricles which was calculated from printed-out CT numbers, great individual variations were recognized in the degree of a ventricular enlargement as well as the rate of EDP. They are thought to be due to the difference in types of hydrocephalus, which have been induced by a discrepancy in the site and degree of an obstruction caused by kaolin. Periventricular lucency (PVL) of various degrees were also detected on CT scans of experimental hydrocephalus. It was always marked in the superolateral angle of frontal horn of the lateral ventricles, and differed in degree from severe to mild. PVLs were distinct in the acute stage with high EDP, and gradually became indistinct and had a tendency to disappear thereafter along with decreased EDP. They immediately disappeared after shunting operation. The pathogenesis of PVL was investigated with histological examinations, as well as by using contrast enhancement, Metrizamide ventriculography, the analysis of linear density profiles, and the measurement of regional cerebral blood flow (rCBF). Consequently, PVLs in hydrocephalus are considered to represent an acute edema or a chronic CSF retention in the periventricular white matter caused by increase of water content. In other words, they are regarded as a sign of present or preceding intraventricular hypertension on CT scan, and may become a clinical indication for shunting operation. (author)

  3. Matlab enhanced multi-threaded tomography optimization sequence (MEMTOS)

    International Nuclear Information System (INIS)

    Lum, Edward S.; Pope, Chad L.

    2016-01-01

    Highlights: • Monte Carlo simulation of spent nuclear fuel assembly neutron computed tomography. • Optimized parallel calculations conducted from within the MATLAB environment. • Projection difference technique used to identify anomalies in spent nuclear fuel assemblies. - Abstract: One challenge associated with spent nuclear fuel assemblies is the lack of non-destructive analysis techniques to determine if fuel pins have been removed or replaced or if there are significant defects associated with fuel pins deep within a fuel assembly. Neutron computed tomography is a promising technique for addressing these qualitative issues. Monte Carlo simulation of spent nuclear fuel neutron computed tomography allows inexpensive process investigation and optimization. The main purpose of this work is to provide a fully automated advanced simulation framework for the analysis of spent nuclear fuel inspection using neutron computed tomography. The simulation framework, called Matlab Enhanced Multi-Threaded Tomography Optimization Sequence (MEMTOS) not only automates the simulation process, but also generates superior tomography image results. MEMTOS is written in the MATLAB scripting language and addresses file management, parallel Monte Carlo execution, results extraction, and tomography image generation. This paper describes the mathematical basis for neutron computed tomography, the Monte Carlo technique used to simulate neutron computed tomography, and the overall tomography simulation optimization algorithm. Sequence results presented include overall simulation speed enhancement, tomography and image results obtained for Experimental Breeder Reactor II spent fuel assemblies and light water reactor fuel assemblies. Optimization using a projection difference technique are also described.

  4. Experimental Study on Bioluminescence Tomography with Multimodality Fusion

    Directory of Open Access Journals (Sweden)

    Yujie Lv

    2007-01-01

    Full Text Available To verify the influence of a priori information on the nonuniqueness problem of bioluminescence tomography (BLT, the multimodality imaging fusion based BLT experiment is performed by multiview noncontact detection mode, which incorporates the anatomical information obtained by the microCT scanner and the background optical properties based on diffuse reflectance measurements. In the reconstruction procedure, the utilization of adaptive finite element methods (FEMs and a priori permissible source region refines the reconstructed results and improves numerical robustness and efficiency. The comparison between the absence and employment of a priori information shows that multimodality imaging fusion is essential to quantitative BLT reconstruction.

  5. Optical Coherence Tomography Study of Experimental Anterior Ischemic Optic Neuropathy and Histologic Confirmation

    Science.gov (United States)

    Ho, Joyce K.; Stanford, Madison P.; Shariati, Mohammad A.; Dalal, Roopa; Liao, Yaping Joyce

    2013-01-01

    Purpose. The optic nerve is part of the central nervous system, and interruption of this pathway due to ischemia typically results in optic atrophy and loss of retinal ganglion cells. In this study, we assessed in vivo retinal changes following murine anterior ischemic optic neuropathy (AION) by using spectral-domain optical coherence tomography (SD-OCT) and compared these anatomic measurements to that of histology. Methods. We induced ischemia at the optic disc via laser-activated photochemical thrombosis, performed serial SD-OCT and manual segmentation of the retinal layers to measure the ganglion cell complex (GCC) and total retinal thickness, and correlated these measurements with that of histology. Results. There was impaired perfusion and leakage at the optic disc on fluorescein angiography immediately after AION and severe swelling and distortion of the peripapillary retina on day-1. We used SD-OCT to quantify the changes in retinal thickness following experimental AION, which revealed significant thickening of the GCC on day-1 after ischemia followed by gradual thinning that plateaued by week-3. Thickness of the peripapillary sensory retina was also increased on day-1 and thinned chronically. This pattern of acute retinal swelling and chronic thinning on SD-OCT correlated well with changes seen in histology and corresponded to loss of retinal ganglion layer cells after ischemia. Conclusions. This was a serial SD-OCT quantification of acute and chronic changes following experimental AION, which revealed changes in the GCC similar to that of human AION, but over a time frame of weeks rather than months. PMID:23887804

  6. Recent advances in neutron tomography

    International Nuclear Information System (INIS)

    McFarland, E.; Massachusetts Inst. of Technology, Cambridge, MA; Lanza, R.

    1993-01-01

    Neutron imaging has been shown to be an excellent imaging tool for many nondestructive evaluation applications. Significantly improved contrast over X-ray images is possible for materials commonly found in engineering assemblies. The major limitations have been the neutron source and detection. A low cost, position sensitive neutron tomography detector system has been designed and built based on an electro-optical detector system using a LiF-ZnS scintillator screen and a cooled charge coupled device. This detector system can be used for neutron radiography as well as two and three-dimensional neutron tomography. Calculated performance of the system predicted near-quantum efficiency for position sensitive neutron detection. Experimental data was recently taken using this system at McClellan Air Force Base, Air Logistics Center, Sacramento, CA. With increased availability of low cost neutron sources and advanced image processing, neutron tomography will become an increasingly important nondestructive imaging method

  7. Development and applications of STIM- and PIXE-tomography: A review

    International Nuclear Information System (INIS)

    Michelet, C.; Barberet, P.; Moretto, P.; Seznec, H.

    2015-01-01

    In combination with nuclear microprobes, STIM and PIXE tomography offer non-destructive quantitative three-dimensional characterization of microscopic samples. STIM tomography provides 3D density maps of the analyzed sample with sub-micrometer resolution and PIXE tomography is one of the only methods allowing a quantification of trace elements in three dimensions. These tomography techniques have been developed in several microbeam laboratories around the world since the 80’s. Nevertheless, despite a huge interest in mapping the inner content of a sample without destroying it, the use of ion beam tomography has been limited to a few studies up to now. This comes from the specific requirements of this kind of experiments, i.e. specific experimental set-up (rotation of the sample during analysis) and reconstruction software, making this type of experiments difficult to handle and relatively long. For a few years, efforts have been made to facilitate the implementation of these techniques and reduce the duration of data acquisition: new detectors and new algorithms were proposed. After an introduction to ion beam tomography techniques and to the first developments made in that field, the experimental and data processing specificities of this 3D imaging approach will be discussed. Finally, examples of recent applications to biology and material science are presented, as well as related techniques developed in the field of microbeam 3D imaging.

  8. Development and applications of STIM- and PIXE-tomography: A review

    Energy Technology Data Exchange (ETDEWEB)

    Michelet, C., E-mail: michelet@cenbg.in2p3.fr; Barberet, P., E-mail: barberet@cenbg.in2p3.fr; Moretto, P., E-mail: moretto@cenbg.in2p3.fr; Seznec, H., E-mail: herve.seznec@cenbg.in2p3.fr

    2015-11-15

    In combination with nuclear microprobes, STIM and PIXE tomography offer non-destructive quantitative three-dimensional characterization of microscopic samples. STIM tomography provides 3D density maps of the analyzed sample with sub-micrometer resolution and PIXE tomography is one of the only methods allowing a quantification of trace elements in three dimensions. These tomography techniques have been developed in several microbeam laboratories around the world since the 80’s. Nevertheless, despite a huge interest in mapping the inner content of a sample without destroying it, the use of ion beam tomography has been limited to a few studies up to now. This comes from the specific requirements of this kind of experiments, i.e. specific experimental set-up (rotation of the sample during analysis) and reconstruction software, making this type of experiments difficult to handle and relatively long. For a few years, efforts have been made to facilitate the implementation of these techniques and reduce the duration of data acquisition: new detectors and new algorithms were proposed. After an introduction to ion beam tomography techniques and to the first developments made in that field, the experimental and data processing specificities of this 3D imaging approach will be discussed. Finally, examples of recent applications to biology and material science are presented, as well as related techniques developed in the field of microbeam 3D imaging.

  9. Avaliação do efeito da laserterapia em baixa intensidade na reparação óssea após radioterapia externa – estudo experimental em ratos

    OpenAIRE

    Paixão, Darcy de Almeida

    2013-01-01

    Esse estudo teve como objetivo avaliar o efeito da Laserterapia em baixa intensidade na reparação de feridas cirúrgicas produzidas no tecido ósseo de ratos da raça Wistar. Para isso, foi artificialmente produzido um orifício no fêmur dos ratos e quatro dias após, os ratos foram submetidos a radioterapia externa com fonte de cobalto radioativo na dosagem de 3000 cGys. O grupo experimental recebeu adicionalmente sete sessões de Laserterapia de 780 hm, 40 nW, 100 J/cm2, por 100 seg. (qu...

  10. Maximum entropy beam diagnostic tomography

    International Nuclear Information System (INIS)

    Mottershead, C.T.

    1985-01-01

    This paper reviews the formalism of maximum entropy beam diagnostic tomography as applied to the Fusion Materials Irradiation Test (FMIT) prototype accelerator. The same formalism has also been used with streak camera data to produce an ultrahigh speed movie of the beam profile of the Experimental Test Accelerator (ETA) at Livermore

  11. Polarimetry data inversion in conditions of tokamak plasma: Model based tomography concept

    International Nuclear Information System (INIS)

    Bieg, B.; Chrzanowski, J.; Kravtsov, Yu. A.; Mazon, D.

    2015-01-01

    Highlights: • Model based plasma tomography is presented. • Minimization procedure for the error function is suggested to be performed using the gradient method. • model based procedure of data inversion in the case of joint polarimetry–interferometry data. - Abstract: Model based plasma tomography is studied which fits a hypothetical multi-parameter plasma model to polarimetry and interferometry experimental data. Fitting procedure implies minimization of the error function, defined as a sum of squared differences between theoretical and empirical values. Minimization procedure for the function is suggested to be performed using the gradient method. Contrary to traditional tomography, which deals exclusively with observational data, model-based tomography (MBT) operates also with reasonable model of inhomogeneous plasma distribution and verifies which profile of a given class better fits experimental data. Model based tomography (MBT) restricts itself by definite class of models for instance power series, Fourier expansion etc. The basic equations of MBT are presented which generalize the equations of model based procedure of polarimetric data inversion in the case of joint polarimetry–interferometry data.

  12. Polarimetry data inversion in conditions of tokamak plasma: Model based tomography concept

    Energy Technology Data Exchange (ETDEWEB)

    Bieg, B. [Maritime University of Szczecin, Waly Chrobrego 1-2, 70-500 Szczecin (Poland); Chrzanowski, J., E-mail: j.chrzanowski@am.szczecin.pl [Maritime University of Szczecin, Waly Chrobrego 1-2, 70-500 Szczecin (Poland); Kravtsov, Yu. A. [Maritime University of Szczecin, Waly Chrobrego 1-2, 70-500 Szczecin (Poland); Space Research Institute, Profsoyuznaya St. 82/34 Russian Academy of Science, Moscow 117997 (Russian Federation); Mazon, D. [CEA, IRFM, F-13108 Saint Paul-lez-Durance (France)

    2015-10-15

    Highlights: • Model based plasma tomography is presented. • Minimization procedure for the error function is suggested to be performed using the gradient method. • model based procedure of data inversion in the case of joint polarimetry–interferometry data. - Abstract: Model based plasma tomography is studied which fits a hypothetical multi-parameter plasma model to polarimetry and interferometry experimental data. Fitting procedure implies minimization of the error function, defined as a sum of squared differences between theoretical and empirical values. Minimization procedure for the function is suggested to be performed using the gradient method. Contrary to traditional tomography, which deals exclusively with observational data, model-based tomography (MBT) operates also with reasonable model of inhomogeneous plasma distribution and verifies which profile of a given class better fits experimental data. Model based tomography (MBT) restricts itself by definite class of models for instance power series, Fourier expansion etc. The basic equations of MBT are presented which generalize the equations of model based procedure of polarimetric data inversion in the case of joint polarimetry–interferometry data.

  13. Ionic and non-ionic contrast media used for contrast-enhanced computed tomography in experimental pancreatitis

    International Nuclear Information System (INIS)

    Kivisaari, L.; Nuutinen, P.; Lehtola, A.; Saari, A.; Pitkaeranta, P.; Standertskjoeld-Nordenstam, C.G.; Lempinen, M.; Schroeder, T.; Helsinki Univ. Central Hospital

    1988-01-01

    Contrast enhancement of the pancreas was studied in pigs using dynamic computed tomography in experimental oedematous and haemorrhagic/necrotizing pancreatitis during the first two minutes after injection of an intravenous bolus of non-ionic contrast medium (iohexol). The prospects of separating the two forms of the disease, known to be possible with ionic contrast media, were tested with a non-ionic contrast medium. In the oedematous form, contrast enhancement after 5 hours of the disease was significantly higher than in the haemorrhagic/necrotizing form. Contrast enhancement after 30 hours of disease tended to vary with the severity of the disease, showing that the course of oedematous pancreatitis is dynamic. Intermediate forms occur and follow-up studies are needed during the disease. A non-ionic contrast medium proved as good for separating the two forms of the disease in the early phase as were ionic contrast media. In severely ill patients, non-ionic contrast media should therefore be used. (orig.)

  14. FMT-XCT: in vivo animal studies with hybrid fluorescence molecular tomography-X-ray computed tomography.

    Science.gov (United States)

    Ale, Angelique; Ermolayev, Vladimir; Herzog, Eva; Cohrs, Christian; de Angelis, Martin Hrabé; Ntziachristos, Vasilis

    2012-06-01

    The development of hybrid optical tomography methods to improve imaging performance has been suggested over a decade ago and has been experimentally demonstrated in animals and humans. Here we examined in vivo performance of a camera-based hybrid fluorescence molecular tomography (FMT) system for 360° imaging combined with X-ray computed tomography (XCT). Offering an accurately co-registered, information-rich hybrid data set, FMT-XCT has new imaging possibilities compared to stand-alone FMT and XCT. We applied FMT-XCT to a subcutaneous 4T1 tumor mouse model, an Aga2 osteogenesis imperfecta model and a Kras lung cancer mouse model, using XCT information during FMT inversion. We validated in vivo imaging results against post-mortem planar fluorescence images of cryoslices and histology data. Besides offering concurrent anatomical and functional information, FMT-XCT resulted in the most accurate FMT performance to date. These findings indicate that addition of FMT optics into the XCT gantry may be a potent upgrade for small-animal XCT systems.

  15. Maximum entropy beam diagnostic tomography

    International Nuclear Information System (INIS)

    Mottershead, C.T.

    1985-01-01

    This paper reviews the formalism of maximum entropy beam diagnostic tomography as applied to the Fusion Materials Irradiation Test (FMIT) prototype accelerator. The same formalism has also been used with streak camera data to produce an ultrahigh speed movie of the beam profile of the Experimental Test Accelerator (ETA) at Livermore. 11 refs., 4 figs

  16. Efeito da utilização de um centrifugado de medula óssea no tratamento de lesão muscular: estudo experimental em coelhos Effect of use of bone-marrow centrifugate on muscle injury treatment: experimental study on rabbits

    Directory of Open Access Journals (Sweden)

    Daniel Ferreira Fernandes Vieira

    2011-01-01

    Full Text Available OBJETIVO: O objetivo deste estudo foi de avaliar o efeito de um centrifugado de medula óssea na cicatrização de lesão muscular em coelhos. MÉTODOS: Este estudo experimental envolveu a utilização de 15 coelhos machos, adultos, da raça Nova Zelândia Branco. Em cada animal, realizou-se uma lesão transversal na região média do músculo tibial anterior direito, onde se adicionou uma esponja de colágeno absorvível, embebida em um centrifugado de aspirado de medula óssea do osso ilíaco ipsilateral. O membro posterior esquerdo foi utilizado como controle, sendo submetido à mesma lesão; porém, neste caso, adicionando-se somente a esponja de colágeno absorvível. Após 30 dias, os animais foram sacrificados para o estudo da cicatrização muscular. As áreas de cicatrização muscular foram submetidas à análise histológica com histomorfometria, interessando-se a mensuração do número de células musculares em regeneração por micrômetro quadrado e a proporção de fibrose formada. RESULTADOS: O método de centrifugação utilizado neste estudo resultou em uma concentração média de células nucleadas maior que o número destas células nos aspirados originais, sem provocar destruição celular significativa. A adição do centrifugado de medula óssea não resultou em aumento significante do número de células musculares em regeneração em relação ao grupo controle. Também não houve diferença significante na proporção de fibrose formada em relação ao grupo controle. CONCLUSÃO: A administração de centrifugado de medula óssea utilizada neste estudo não favoreceu a cicatrização de lesão muscular em coelhos.OBJECTIVE: The objective of this study was to evaluate the effect of bone-marrow centrifugate on the healing of muscle injuries in rabbits. METHODS: This experimental study involved use of fifteen adult male New Zealand White rabbits. Each animal received a transverse lesion in the middle of the right

  17. Fault detection using transmission tomography - Evaluation on the Experimental Platform of Tournemire

    International Nuclear Information System (INIS)

    Vi-Nhu-Ba, Elise

    2014-01-01

    Deep argillaceous formations have physical properties adapted to the radioactive waste disposal but their permeability properties can be modified by the presence of fractured zones; detection of these faulted zones are thus of primary importance. Several experiments have been led by IRSN in the Experimental Platform of Tournemire where faults with small vertical offsets in the deep argillaceous formation have been identified from underground installations. Some previous studies have shown the difficulty to detect this fractured zone from surface acquisitions using reflection or refraction seismic but also with electrical methods. We here propose a new seismic transmission acquisition geometry in where seismic sources are deployed at the surface and receivers are installed in the underground installations. In the scope to process these data, a new tomography algorithm has been developed in order to control the inversion parameters and also to introduce a priori information. Several synthetic tests have been led to reliably analyze the results in terms of resolution and relevance of the final image. A discontinuity of the seismic velocities in the limestones and argillites of the Tournemire Platform is evidenced for the first time by applying the algorithm to the data recently acquired. This low velocity anomaly is located just above the fracture zone visible from the underground installations and its location is also consistent with observations from the surface. (author)

  18. Polynomial reconstruction of radial catalyst concentration distribution in an experimental type FCC riser for a low number of transversal projections in gamma ray tomography

    International Nuclear Information System (INIS)

    Melo, Silvio B.; Simoes, Francisco P.M.; Oliveira, Eric F. de; Santos, Maria das Gracas dos; Dantas, Carlos C.

    2007-01-01

    In the FCC - Fluid Catalytic Cracking process the Riser is an opaque cylinder, so that, in order to investigate the catalyst concentration inside, a gamma- ray based tomography is employed. Each section is submitted to a parallel beam and by means of the Beer-Lambert transmission is calculated. This tomography session is repeated from different angles, in manual tomographic experiments where the source/detector pair is rotated, producing in each direction what we called a transversal projection. In order to reconstruct the concentration of the present catalyst in a given moment some methods use successfully the inverse Radon transform through the filtered back-projection algorithm. The results are fully satisfactory for a large number of projections, widely seen as better than those produced by the algebraic methods. For a low number of projections, however, the algebraic methods become more competitive. In practice, simple experimental set-ups work with less than 10 projections, due to the time taken by the whole process. In this work, we present an investigation of polynomial reconstructions by using Bezier surfaces of arbitrary degree, adjusted to the experimental data through a least squares method. A computational algorithm was developed to implement the mathematical reconstruction for the 3D graphics presentation. (author)

  19. Hepatic blood perfusion estimated by dynamic contrast-enhanced computed tomography in pigs

    DEFF Research Database (Denmark)

    Winterdahl, Michael; Sørensen, Michael; Keiding, Inger Susanne

    2012-01-01

    The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates.......The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates....

  20. Impact of errors in experimental parameters on reconstructed breast images using diffuse optical tomography.

    Science.gov (United States)

    Deng, Bin; Lundqvist, Mats; Fang, Qianqian; Carp, Stefan A

    2018-03-01

    Near-infrared diffuse optical tomography (NIR-DOT) is an emerging technology that offers hemoglobin based, functional imaging tumor biomarkers for breast cancer management. The most promising clinical translation opportunities are in the differential diagnosis of malignant vs. benign lesions, and in early response assessment and guidance for neoadjuvant chemotherapy. Accurate quantification of the tissue oxy- and deoxy-hemoglobin concentration across the field of view, as well as repeatability during longitudinal imaging in the context of therapy guidance, are essential for the successful translation of NIR-DOT to clinical practice. The ill-posed and ill-condition nature of the DOT inverse problem makes this technique particularly susceptible to model errors that may occur, for example, when the experimental conditions do not fully match the assumptions built into the image reconstruction process. To evaluate the susceptibility of DOT images to experimental errors that might be encountered in practice for a parallel-plate NIR-DOT system, we simulated 7 different types of errors, each with a range of magnitudes. We generated simulated data by using digital breast phantoms derived from five actual mammograms of healthy female volunteers, to which we added a 1-cm tumor. After applying each of the experimental error types and magnitudes to the simulated measurements, we reconstructed optical images with and without structural prior guidance and assessed the overall error in the total hemoglobin concentrations (HbT) and in the HbT contrast between the lesion and surrounding area vs. the best-case scenarios. It is found that slight in-plane probe misalignment and plate rotation did not result in large quantification errors. However, any out-of-plane probe tilting could result in significant deterioration in lesion contrast. Among the error types investigated in this work, optical images were the least likely to be impacted by breast shape inaccuracies but suffered the

  1. Dual-Modality Imaging of the Human Finger Joint Systems by Using Combined Multispectral Photoacoustic Computed Tomography and Ultrasound Computed Tomography

    Directory of Open Access Journals (Sweden)

    Yubin Liu

    2016-01-01

    Full Text Available We developed a homemade dual-modality imaging system that combines multispectral photoacoustic computed tomography and ultrasound computed tomography for reconstructing the structural and functional information of human finger joint systems. The fused multispectral photoacoustic-ultrasound computed tomography (MPAUCT system was examined by the phantom and in vivo experimental tests. The imaging results indicate that the hard tissues such as the bones and the soft tissues including the blood vessels, the tendon, the skins, and the subcutaneous tissues in the finger joints systems can be effectively recovered by using our multimodality MPAUCT system. The developed MPAUCT system is able to provide us with more comprehensive information of the human finger joints, which shows its potential for characterization and diagnosis of bone or joint diseases.

  2. Feasibility study for mega-electron-volt electron beam tomography.

    Science.gov (United States)

    Hampel, U; Bärtling, Y; Hoppe, D; Kuksanov, N; Fadeev, S; Salimov, R

    2012-09-01

    Electron beam tomography is a promising imaging modality for the study of fast technical processes. But for many technical objects of interest x rays of several hundreds of keV energy are required to achieve sufficient material penetration. In this article we report on a feasibility study for fast electron beam computed tomography with a 1 MeV electron beam. The experimental setup comprises an electrostatic accelerator with beam optics, transmission target, and a single x-ray detector. We employed an inverse fan-beam tomography approach with radiographic projections being generated from the linearly moving x-ray source. Angular projections were obtained by rotating the object.

  3. Tumor hepático experimental (VX-2 em coelho: implantação do modelo no Brasil Experimental liver tumor (VX-2 in rabbits: implantation of the model in Brazil

    Directory of Open Access Journals (Sweden)

    Rogério Saad Hossne

    2002-08-01

    Full Text Available Os estudos para a investigação de novas modalidades terapêuticas em biologia tumoral, deveriam passar por estudos experimentais prévios. Neste sentido dispõem-se hoje de uma grande variedade de modelos tumorais experimentais; em determinadas investigações faz-se necessária a adequação do modelo tumoral às necessidades biológicas, patológicas e experimentais dos estudos. Desta forma, em nosso serviço, buscávamos um modelo tumoral hepático para estudos experimentais que se adequasse às seguintes características: fácil manipulação, crescimento controlável, evolução e agressividade semelhantes aos seres humanos. Os dados da literatura nos levaram a busca do tumor hepático VX-2, em coelhos. Neste artigo discutimos as vantagens da utilização deste modelo experimental e a sua introdução em nosso país.Studies for investigation of new therapeutic modalities in tumoral biology should be based on previous experimental studies. Then, there are a great variety of tumoral experimental models today. Some investigations have been done necessary an adaptation of the tumoral model to the needing of the studies biological and pathological. So, in our laboratory, we looked for a tumoral hepatic model for experimental studies with the following characteristics: easy manipulation, control of growing, evolution and aggressiveness like to humans. Data of the literature took us the search of the hepatic tumor VX-2, in rabbits. In this article we discussed the advantages of use this experimental model and its introduction in our country. Experimental hepatic tumor (VX-2 in rabbit. Implantation of the model in Brazil.

  4. Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging

    International Nuclear Information System (INIS)

    Chen, Dongmei; Zhu, Shouping; Chen, Xueli; Chao, Tiantian; Cao, Xu; Zhao, Fengjun; Huang, Liyu; Liang, Jimin

    2014-01-01

    X-ray luminescence tomography (XLT) is an imaging technology based on X-ray-excitable materials. The main purpose of this paper is to obtain quantitative luminescence concentration using the structural information of the X-ray computed tomography (XCT) in the hybrid cone beam XLT/XCT system. A multi-wavelength luminescence cone beam XLT method with the structural a priori information is presented to relieve the severe ill-posedness problem in the cone beam XLT. The nanophosphors and phantom experiments were undertaken to access the linear relationship of the system response. Then, an in vivo mouse experiment was conducted. The in vivo experimental results show that the recovered concentration error as low as 6.67% with the location error of 0.85 mm can be achieved. The results demonstrate that the proposed method can accurately recover the nanophosphor inclusion and realize the quantitative imaging

  5. Positron emission tomography imaging of gene expression

    International Nuclear Information System (INIS)

    Tang Ganghua

    2001-01-01

    The merging of molecular biology and nuclear medicine is developed into molecular nuclear medicine. Positron emission tomography (PET) of gene expression in molecular nuclear medicine has become an attractive area. Positron emission tomography imaging gene expression includes the antisense PET imaging and the reporter gene PET imaging. It is likely that the antisense PET imaging will lag behind the reporter gene PET imaging because of the numerous issues that have not yet to be resolved with this approach. The reporter gene PET imaging has wide application into animal experimental research and human applications of this approach will likely be reported soon

  6. Computed tomography study of otitis media; A tomografia computadorizada no estudo das otites medias

    Energy Technology Data Exchange (ETDEWEB)

    Bahia, Paulo Roberto Valle; Marchiori, Edson [Universidade Federal, Rio de Janeiro, RJ (Brazil). Dept. de Radiologia

    1997-03-01

    The findings of computed tomography (CT) of 89 patients clinically suspected of having otitis media were studied in this work. Such results were compared to clinical diagnosis, otoscopy, surgical findings and previous data. Among the results of our analysis, we studied seven patients with acute otitis media and 83 patients with chronic otitis media. The patients with acute otitis media have undergone CT examinations to evaluate possible spread to central nervous system. The diagnosis of cholesteatoma, its extension and complications were the main indication. for chronic otitis media study. The main findings of the cholesteatomatous otitis were the occupation of the epitympanun, the bony wall destruction and the ossicular chain erosion. The CT demonstrated a great sensibility to diagnose the cholesteatoma. (author) 25 refs., 10 figs.

  7. Application of positron emission tomography in the heart

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This report discusses experimental and clinical applications of positron emission tomography to the heart, including measurements of blood flow to the myocardium and studies of metabolism and experimental injury. Most initial clinical studies have concentrated on ischemic heart disease, but the technique also has potential for investigation of cardiomyopathies, studying the neural control of the heart, and evaluating the effects of drugs on cardiac tissues

  8. Estudo experimental do reforço à flexão em vigas de concreto armado com balanço utilizando compósitos com tecidos de fibras de carbono

    OpenAIRE

    Araújo, Ana; Sánchez, Emil; Velasco, Marta

    2004-01-01

    Esse trabalho apresenta um estudo sobre o comportamento e o desempenho de vigas de concreto armado reforçadas à flexão utilizando-se compósitos de fibra de carbono. O programa experimental constituído pelo ensaio de sete vigas biapoiadas com um vão em balanço, todas com a mesma seção transversal, armaduras de aço e vãos idênticos, sendo o momento positivo máximo igual ao do momento negativo máximo. O concreto utilizado foi projetado para fornecer uma resistência à compressão de 20 MPa e o aço...

  9. Estudo do Efeito Neuroprotetor do Eugenol em Modelo Experimental da Doença de Huntington

    OpenAIRE

    Nóbrega, Rafaella Farias da

    2013-01-01

    O envelhecimento da população é um dos maiores triunfos da humanidade e também um dos grandes desafios. No entanto, o crescimento da expectativa de vida da população tem levado a um aumento na incidência de doenças características do envelhecimento e tem proporcionado um interesse, cada vez maior, em estudos que visam novas estratégias para a prevenção e cura destas patologias. Várias evidências têm demonstrado que alterações mitocondriais e elevados níveis de estresse oxidativo estão forteme...

  10. Estudo de propriedades físico-químicas envolvidas no processo de compactação de uma formulação experimental contendo zidovudina

    Directory of Open Access Journals (Sweden)

    Tatiana Angiolucci

    2012-04-01

    Full Text Available Estudo das propriedades físico-químicas envolvidos no processo de compactação de uma formulação experimental contendo como fármaco modelo a zidovudina. O objetivo foi caracterizar o comportamento físico-químico de comprimidos produzidos por compressão direta usando-se diferentes pressões de compactação. Nas análises foram empregadas metodologias convencionais e não convencionais. A metodologia não convencional foi o uso da técnica da atenuação de raios-gama na determinação da porosidade. As metodologias convencionais utilizadas foram os testes de friabilidade, dureza e dissolução. Os modelos teóricos utilizados para explicar o comportamento físico-químico da formulação sob compressão são os proposto por Heckel e Walker. Os estudos mostraram que o processo de densificação é governado principalmente por deformações do tipo plásticas e pressões em torno de 246MPa são suficientes para induzir deformação plástica e consolidação do sistema compactado. Os resultados da análise de Walker indicam que a formulação tem propriedades de compressão que podem ser melhoradas.

  11. Toward quantitative core-loss EFTEM tomography

    International Nuclear Information System (INIS)

    Jin-Phillipp, N.Y.; Koch, C.T.; Aken, P.A. van

    2011-01-01

    Core-loss EFTEM tomography provides three-dimensional structural and chemical information. Multiple inelastic scattering occurring in thick specimens as well as orientation-dependent diffraction contrast due to multiple elastic scattering, however, often limit its applications. After demonstrating the capability of core-loss EFTEM tomography to reconstruct just a few monolayers thin carbon layer covering a Fe catalyst particle we discuss its application to thicker samples. We propose an approximate multiple-scattering correction method based on the use of zero-loss images and apply it successfully to copper whiskers, providing a significant improvement of the reconstructed 3D elemental distribution. We conclude this paper by a general discussion on experimental parameters affecting the accuracy of EFTEM 3D elemental mapping. -- Research highlights: → EFTEM 3D elemental mapping has been applied to a catalyst particle from which a CNT has grown and a copper whisker. → Correction of multiple inelastic scattering shows significant improvements in the reconstruction of 3D elemental maps. → Experimental parameters affecting the accuracy of EFTEM 3D elemental mapping are discussed.

  12. Estudos de atmosfera

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Riccioppo

    2016-11-01

    Full Text Available Joker e Estudos de balística possuíam formas distintas dos cadernos ou livros quando foram exibidos pela primeira vez, na mostra Dual Overdrive. De algum modo, o flagrante das imagens dos cartazes da campanha política parisiense e daquelas cusparadas sobre o asfalto era preservado no modo como eram mostrados os trabalhos, que repunham não apenas a orientação espacial dos objetos fotografados, mas, igualmente, sua escala: Joker apresentava-se na parede, em dimensões relativamente próximas às dos cartazes lambe-lambe que retratavam; e Estudos de balística, no chão da galeria, também com ampliação suficiente para que se tivesse a impressão de que se tratava de imagens “em tamanho real”.

  13. ESTUDOS ESTILÍSTICOS NO BRASIL

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Falcão Uchôa

    2013-06-01

    Full Text Available Este artigo objetiva mostrar os inícios e a progressão dos estudos estilísticos no Brasil. Após uma introdução sobre o surgimento, na Europa, da Estilística como disciplina de pesquisa no campo da linguagem, detém-se, sucessivamente, nas contribuições de filólogos, linguistas, teóricos da literatura e gramáticos para o estudo dos mais variados recursos estilísticos ocorrentes sobretudo em autores brasileiros.

  14. Towards adaptive, streaming analysis of x-ray tomography data

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Mathew; Kleese van Dam, Kerstin; Marshall, Matthew J.; Kuprat, Andrew P.; Carson, James P.; Lansing, Carina S.; Guillen, Zoe C.; Miller, Erin A.; Lanekoff, Ingela; Laskin, Julia

    2015-03-04

    Temporal and spatial resolution of chemical imaging methodologies such as x-ray tomography are rapidly increasing, leading to more complex experimental procedures and fast growing data volumes. Automated analysis pipelines and big data analytics are becoming essential to effectively evaluate the results of such experiments. Offering those data techniques in an adaptive, streaming environment can further substantially improve the scientific discovery process, by enabling experimental control and steering based on the evaluation of emerging phenomena as they are observed by the experiment. Pacific Northwest National Laboratory (PNNL)’ Chemical Imaging Initiative (CII - http://imaging.pnnl.gov/ ) has worked since 2011 towards developing a framework that allows users to rapidly compose and customize high throughput experimental analysis pipelines for multiple instrument types. The framework, named ‘Rapid Experimental Analysis’ (REXAN) Framework [1], is based on the idea of reusable component libraries and utilizes the PNNL developed collaborative data management and analysis environment ‘Velo’, to provide a user friendly analysis and data management environment for experimental facilities. This article will, discuss the capabilities established for X-Ray tomography, discuss lessons learned, and provide an overview of our more recent work in the Analysis in Motion Initiative (AIM - http://aim.pnnl.gov/ ) at PNNL to provide REXAN capabilities in a streaming environment.

  15. O desamparo aprendido revisitado: estudos com animais

    Directory of Open Access Journals (Sweden)

    Maria Helena Leite Hunziker

    Full Text Available O desamparo aprendido tem sido definido como a dificuldade de aprendizagem apresentada por indivíduos que tiveram experiência prévia com estímulos aversivos incontroláveis. O objetivo deste trabalho é fazer uma revisão crítica dos estudos sobre o desamparo aprendido, com animais. Nessa análise, são considerados aspectos conceituais e metodológicos dos estudos em questão e as interpretações teóricas sobre esse efeito comportamental. Aborda-se a evolução histórica desses estudos, bem como alguns aspectos controversos das publicações que se acumularam ao longo de quatro décadas de pesquisa. A associação do desamparo aprendido com a depressão clínica é analisada criticamente, destacando-se a necessidade de maior rigor metodológico e conceitual nos estudos da área.

  16. Efficient gate set tomography on a multi-qubit superconducting processor

    Science.gov (United States)

    Nielsen, Erik; Rudinger, Kenneth; Blume-Kohout, Robin; Bestwick, Andrew; Bloom, Benjamin; Block, Maxwell; Caldwell, Shane; Curtis, Michael; Hudson, Alex; Orgiazzi, Jean-Luc; Papageorge, Alexander; Polloreno, Anthony; Reagor, Matt; Rubin, Nicholas; Scheer, Michael; Selvanayagam, Michael; Sete, Eyob; Sinclair, Rodney; Smith, Robert; Vahidpour, Mehrnoosh; Villiers, Marius; Zeng, William; Rigetti, Chad

    Quantum information processors with five or more qubits are becoming common. Complete, predictive characterization of such devices e.g. via any form of tomography, including gate set tomography appears impossible because the parameter space is intractably large. Randomized benchmarking scales well, but cannot predict device behavior or diagnose failure modes. We introduce a new type of gate set tomography that uses an efficient ansatz to model physically plausible errors, but scales polynomially with the number of qubits. We will describe the theory behind this multi-qubit tomography and present experimental results from using it to characterize a multi-qubit processor made by Rigetti Quantum Computing. Sandia National Laboratories is a multi-mission laboratory managed and operated by Sandia Corporation, a wholly owned subsidary of Lockheed Martin Corporation, for the US Department of Energy's NNSA under contract DE-AC04-94AL85000.

  17. 3D imaging of nanomaterials by discrete tomography.

    Science.gov (United States)

    Batenburg, K J; Bals, S; Sijbers, J; Kübel, C; Midgley, P A; Hernandez, J C; Kaiser, U; Encina, E R; Coronado, E A; Van Tendeloo, G

    2009-05-01

    The field of discrete tomography focuses on the reconstruction of samples that consist of only a few different materials. Ideally, a three-dimensional (3D) reconstruction of such a sample should contain only one grey level for each of the compositions in the sample. By exploiting this property in the reconstruction algorithm, either the quality of the reconstruction can be improved significantly, or the number of required projection images can be reduced. The discrete reconstruction typically contains fewer artifacts and does not have to be segmented, as it already contains one grey level for each composition. Recently, a new algorithm, called discrete algebraic reconstruction technique (DART), has been proposed that can be used effectively on experimental electron tomography datasets. In this paper, we propose discrete tomography as a general reconstruction method for electron tomography in materials science. We describe the basic principles of DART and show that it can be applied successfully to three different types of samples, consisting of embedded ErSi(2) nanocrystals, a carbon nanotube grown from a catalyst particle and a single gold nanoparticle, respectively.

  18. 3D imaging of nanomaterials by discrete tomography

    International Nuclear Information System (INIS)

    Batenburg, K.J.; Bals, S.; Sijbers, J.; Kuebel, C.; Midgley, P.A.; Hernandez, J.C.; Kaiser, U.; Encina, E.R.; Coronado, E.A.; Van Tendeloo, G.

    2009-01-01

    The field of discrete tomography focuses on the reconstruction of samples that consist of only a few different materials. Ideally, a three-dimensional (3D) reconstruction of such a sample should contain only one grey level for each of the compositions in the sample. By exploiting this property in the reconstruction algorithm, either the quality of the reconstruction can be improved significantly, or the number of required projection images can be reduced. The discrete reconstruction typically contains fewer artifacts and does not have to be segmented, as it already contains one grey level for each composition. Recently, a new algorithm, called discrete algebraic reconstruction technique (DART), has been proposed that can be used effectively on experimental electron tomography datasets. In this paper, we propose discrete tomography as a general reconstruction method for electron tomography in materials science. We describe the basic principles of DART and show that it can be applied successfully to three different types of samples, consisting of embedded ErSi 2 nanocrystals, a carbon nanotube grown from a catalyst particle and a single gold nanoparticle, respectively.

  19. Angiographic and artefact-free computed tomography imaging of experimental aneurysms embolised with hydrogel filaments

    Energy Technology Data Exchange (ETDEWEB)

    McCoy, Mark R. [Paracelsus Medical University, Department of Radiology and Magnetic Resonance Tomography, Christian Doppler Clinic, Salzburg (Austria); Cruise, Gregory M. [MicroVention Terumo, Aliso Viejo, CA (United States); Killer, Monika [Paracelsus Medical University, Department of Neurology/Neuroscience Institute, Christian Doppler Clinic, Salzburg (Austria)

    2010-04-15

    We compared experimental rabbit carotid bifurcation aneurysms embolised with platinum coils or hydrogel filaments by using digital subtraction angiography (DSA) and computed tomography angiography (CTA). Embolisation was performed using platinum coils (n = 2), hydrogel filaments loaded with iodine (n = 3) and hydrogel filaments loaded with barium sulphate (n = 3). In one case, a stent was deployed in the parent vessel to determine the effect of hydrogel filaments on stent visualisation. DSA evaluations occurred immediately post-treatment. CTA evaluations occurred at 0-13 weeks post-treatment. The DSA and CTA images were evaluated for the lack of artefacts and the visibilities of the embolic mass, individual coils and residual flow in the aneurysm sac and neck. The DSA results were largely concordant among the three groups. The embolic masses were readily evident with some individual coils being distinguished. In the aneurysms embolised with hydrogel filaments, visualisation of the individual coils, residual flow and stent with minor or no artefacts was possible using CTA. On the other hand, the beam hardening artefacts precluded analysis of aneurysms embolised with platinum coils. CTA-compatible embolic devices could have wide applications in diverse locations throughout the vasculature, particularly in combination with stents or stent grafts. (orig.)

  20. Toracoscopia nas hérnias diafragmáticas: estudo experimental em cães Thoracoscopic techniques in diaphragmatic hernias: experimental study in dogs

    Directory of Open Access Journals (Sweden)

    Carlos Afonso de Castro Beck

    2004-12-01

    Full Text Available Na classificação das hérnias diafragmáticas, a traumática é a forma mais prevalente em cães e gatos. A alteração, que se caracteriza por uma alteração anatômica, tem na correção cirúrgica, o tratamento recomendado. O presente estudo se propôs a avaliar a cirurgia videotoracoscópica no diagnóstico e tratamento de hérnias diafragmáticas em cães. Na primeira etapa do experimento, oito animais foram submetidos à produção de um modelo de hérnia diafragmática por meio do acesso laparoscópico. Após o período de uma semana, os cães foram submetidos à segunda etapa experimental através do acesso toracoscópico, tendo como finalidade o diagnóstico e a terapêutica cirúrgica. O acesso toracoscópico mostrou-se eficaz tanto no caráter diagnóstico das rupturas e dos deslocamentos, como na correção cirúrgica de reposição visceral e rafia diafragmática.The most common type of diaphragmatic hernia in dogs and cats is the traumatic one.As an anatomic alteration surgery is the elected treatment. The purpose of this study was to evaluate videothoracoscopic surgery in the diagnostic and treatment of diaphragmatic hernia in eight dogs. In the first phase of the study diaphragmatic hernias were performed in the dogs through laparoscopic access. One week later the dogs were summited to a thoracoscopic surgery to make diagnostic and surgical correction. Thoracoscopic access showed to be efficient for identification of the defects and visceral displacements and for the surgical treatment.

  1. Laparoscopia nas hérnias diafragmáticas: estudo experimental em cães Laparoscopic techniques in diaphragmatic hernias: experimental study in dogs

    Directory of Open Access Journals (Sweden)

    Carlos Afonso de Castro Beck

    2004-12-01

    Full Text Available A hérnia diafragmática traumática é a forma mais comum entre as hérnias diafragmáticas em cães e gatos e, por tratar-se de uma alteração anatômica, a terapêutica indicada é a sua correção cirúrgica. O presente estudo se propôs a avaliar a cirurgia videolaparoscópica no diagnóstico e tratamento dessa afecção em cães. Na primeira etapa do experimento, os animais foram submetidos à produção de um modelo de hérnia diafragmática. Após o período de uma semana, os cães foram submetidos à segunda etapa experimental por meio do acesso laparoscópico, tendo como finalidade o diagnóstico e a terapêutica cirúrgica. O acesso laparoscópico mostrou-se eficaz tanto na identificação das rupturas e dos deslocamentos como na correção cirúrgica de reposição visceral e rafia diafragmática nos oito cães do experimento.The most common type of diaphragmatic hernia in dogs and cats is the traumatic one. As an anatomic alteration, surgery is the elected treatment. The purpose of this study was to evaluate videolaparoscopic surgery in the diagnostic and treatment of diaphragmatic hernia in dogs. In the first phase of the study diaphragmatic hernias were performed in dogs. One week later the dogs were summited to a laparoscopic surgery to make diagnostic and surgical correction. Laparoscopic access showed to be efficient for identification of the defect and visceral displacement and for the surgical treatment.

  2. Automated discrete electron tomography – Towards routine high-fidelity reconstruction of nanomaterials

    International Nuclear Information System (INIS)

    Zhuge, Xiaodong; Jinnai, Hiroshi; Dunin-Borkowski, Rafal E.; Migunov, Vadim; Bals, Sara; Cool, Pegie; Bons, Anton-Jan; Batenburg, Kees Joost

    2017-01-01

    Electron tomography is an essential imaging technique for the investigation of morphology and 3D structure of nanomaterials. This method, however, suffers from well-known missing wedge artifacts due to a restricted tilt range, which limits the objectiveness, repeatability and efficiency of quantitative structural analysis. Discrete tomography represents one of the promising reconstruction techniques for materials science, potentially capable of delivering higher fidelity reconstructions by exploiting the prior knowledge of the limited number of material compositions in a specimen. However, the application of discrete tomography to practical datasets remains a difficult task due to the underlying challenging mathematical problem. In practice, it is often hard to obtain consistent reconstructions from experimental datasets. In addition, numerous parameters need to be tuned manually, which can lead to bias and non-repeatability. In this paper, we present the application of a new iterative reconstruction technique, named TVR-DART, for discrete electron tomography. The technique is capable of consistently delivering reconstructions with significantly reduced missing wedge artifacts for a variety of challenging data and imaging conditions, and can automatically estimate its key parameters. We describe the principles of the technique and apply it to datasets from three different types of samples acquired under diverse imaging modes. By further reducing the available tilt range and number of projections, we show that the proposed technique can still produce consistent reconstructions with minimized missing wedge artifacts. This new development promises to provide the electron microscopy community with an easy-to-use and robust tool for high-fidelity 3D characterization of nanomaterials. - Highlights: • Automated discrete electron tomography capable of consistently delivering reconstructions with significantly reduced missing wedge artifacts and requires significantly

  3. Automated discrete electron tomography – Towards routine high-fidelity reconstruction of nanomaterials

    Energy Technology Data Exchange (ETDEWEB)

    Zhuge, Xiaodong [Computational Imaging, Centrum Wiskunde & Informatica, Science park 123, 1098XG Amsterdam (Netherlands); Jinnai, Hiroshi [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Katahira 2-1-1, Aoba-ku, Sendai 980-8577 (Japan); Dunin-Borkowski, Rafal E.; Migunov, Vadim [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Bals, Sara [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Cool, Pegie [Laboratory of Adsorption and Catalysis, Department of Chemistry, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium); Bons, Anton-Jan [European Technology Center, ExxonMobil Chemical Europe Inc., Hermeslaan 2, B-1831 Machelen (Belgium); Batenburg, Kees Joost [Computational Imaging, Centrum Wiskunde & Informatica, Science park 123, 1098XG Amsterdam (Netherlands)

    2017-04-15

    Electron tomography is an essential imaging technique for the investigation of morphology and 3D structure of nanomaterials. This method, however, suffers from well-known missing wedge artifacts due to a restricted tilt range, which limits the objectiveness, repeatability and efficiency of quantitative structural analysis. Discrete tomography represents one of the promising reconstruction techniques for materials science, potentially capable of delivering higher fidelity reconstructions by exploiting the prior knowledge of the limited number of material compositions in a specimen. However, the application of discrete tomography to practical datasets remains a difficult task due to the underlying challenging mathematical problem. In practice, it is often hard to obtain consistent reconstructions from experimental datasets. In addition, numerous parameters need to be tuned manually, which can lead to bias and non-repeatability. In this paper, we present the application of a new iterative reconstruction technique, named TVR-DART, for discrete electron tomography. The technique is capable of consistently delivering reconstructions with significantly reduced missing wedge artifacts for a variety of challenging data and imaging conditions, and can automatically estimate its key parameters. We describe the principles of the technique and apply it to datasets from three different types of samples acquired under diverse imaging modes. By further reducing the available tilt range and number of projections, we show that the proposed technique can still produce consistent reconstructions with minimized missing wedge artifacts. This new development promises to provide the electron microscopy community with an easy-to-use and robust tool for high-fidelity 3D characterization of nanomaterials. - Highlights: • Automated discrete electron tomography capable of consistently delivering reconstructions with significantly reduced missing wedge artifacts and requires significantly

  4. Algorithmic fundamentals of computerized tomography and of transverse analogue tomography

    International Nuclear Information System (INIS)

    Heckmann, K.

    1981-01-01

    Computerized tomography and transverse analogue tomography are two different approaches to the same goal, namely, transverse tomography. The algorithm is discussed and compared. Transverse tomography appears capable of further development, judging by this comparison. (orig.) [de

  5. The ASTRA Toolbox: A platform for advanced algorithm development in electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Aarle, Wim van, E-mail: wim.vanaarle@uantwerpen.be [iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium); Palenstijn, Willem Jan, E-mail: willemjan.palenstijn@uantwerpen.be [iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium); Centrum Wiskunde & Informatica, Science Park 123, NL-1098 XG Amsterdam (Netherlands); De Beenhouwer, Jan, E-mail: jan.debeenhouwer@uantwerpen.be [iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium); Altantzis, Thomas, E-mail: thomas.altantzis@uantwerpen.be [Electron Microscopy for Materials Science, University of Antwerp, Groenenborgerlaan 171, B-2020 Wilrijk (Belgium); Bals, Sara, E-mail: sara.bals@uantwerpen.be [Electron Microscopy for Materials Science, University of Antwerp, Groenenborgerlaan 171, B-2020 Wilrijk (Belgium); Batenburg, K. Joost, E-mail: joost.batenburg@cwi.nl [iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium); Centrum Wiskunde & Informatica, Science Park 123, NL-1098 XG Amsterdam (Netherlands); Mathematical Institute, Leiden University, P.O. Box 9512, NL-2300 RA Leiden (Netherlands); Sijbers, Jan, E-mail: jan.sijbers@uantwerpen.be [iMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium)

    2015-10-15

    We present the ASTRA Toolbox as an open platform for 3D image reconstruction in tomography. Most of the software tools that are currently used in electron tomography offer limited flexibility with respect to the geometrical parameters of the acquisition model and the algorithms used for reconstruction. The ASTRA Toolbox provides an extensive set of fast and flexible building blocks that can be used to develop advanced reconstruction algorithms, effectively removing these limitations. We demonstrate this flexibility, the resulting reconstruction quality, and the computational efficiency of this toolbox by a series of experiments, based on experimental dual-axis tilt series. - Highlights: • The ASTRA Toolbox is an open platform for 3D image reconstruction in tomography. • Advanced reconstruction algorithms can be prototyped using the fast and flexible building blocks. • This flexibility is demonstrated on a common use case: dual-axis tilt series reconstruction with prior knowledge. • The computational efficiency is validated on an experimentally measured tilt series.

  6. The ASTRA Toolbox: A platform for advanced algorithm development in electron tomography

    International Nuclear Information System (INIS)

    Aarle, Wim van; Palenstijn, Willem Jan; De Beenhouwer, Jan; Altantzis, Thomas; Bals, Sara; Batenburg, K. Joost; Sijbers, Jan

    2015-01-01

    We present the ASTRA Toolbox as an open platform for 3D image reconstruction in tomography. Most of the software tools that are currently used in electron tomography offer limited flexibility with respect to the geometrical parameters of the acquisition model and the algorithms used for reconstruction. The ASTRA Toolbox provides an extensive set of fast and flexible building blocks that can be used to develop advanced reconstruction algorithms, effectively removing these limitations. We demonstrate this flexibility, the resulting reconstruction quality, and the computational efficiency of this toolbox by a series of experiments, based on experimental dual-axis tilt series. - Highlights: • The ASTRA Toolbox is an open platform for 3D image reconstruction in tomography. • Advanced reconstruction algorithms can be prototyped using the fast and flexible building blocks. • This flexibility is demonstrated on a common use case: dual-axis tilt series reconstruction with prior knowledge. • The computational efficiency is validated on an experimentally measured tilt series

  7. Coded aperture tomography revisited

    International Nuclear Information System (INIS)

    Bizais, Y.; Rowe, R.W.; Zubal, I.G.; Bennett, G.W.; Brill, A.B.

    1983-01-01

    Coded aperture (CA) Tomography never achieved wide spread use in Nuclear Medicine, except for the degenerate case of Seven Pinhole tomagraphy (7PHT). However it enjoys several attractive features (high sensitivity and tomographic ability with a statis detector). On the other hand, resolution is usually poor especially along the depth axis and the reconstructed volume is rather limited. Arguments are presented justifying the position that CA tomography can be useful for imaging time-varying 3D structures, if its major drawbacks (poor longitudinal resolution and difficulty in quantification) are overcome. Poor results obtained with 7PHT can be explained by both a very limited angular range sampled and a crude modelling of the image formation process. Therefore improvements can be expected by the use of a dual-detector system, along with a better understanding of its sampling properties and the use of more powerful reconstruction algorithms. Non overlapping multipinhole plates, because they do not involve a decoding procedure, should be considered first for practical applications. Use of real CA should be considered for cases in which non overlapping multipinhole plates do not lead to satisfactory solutions. We have been and currently are carrying out theoretical and experimental works, in order to define the factors which limit CA imaging and to propose satisfactory solutions for Dynamic Emission Tomography

  8. Estra: um corpus para o estudo do estilo da tradução

    Directory of Open Access Journals (Sweden)

    Célia Magalhães

    2014-12-01

    Full Text Available Este artigo apresenta a evolução e as contribuições da pesquisa em estudos da tradução orientados para corpora no Brasil. Faz-se uma revisão dos trabalhos iniciais desenvolvidos no Laboratório Experimental de Tradução (LETRA, mostrando que a maioria deles adotava uma abordagem de linguística contrastiva da tradução e que as pesquisas, gradualmente, foram evoluindo para uma preocupação com a estilística tradutória e o estilo do tradutor literário. Também se relata a compilação de um corpus para o estudo do estilo da tradução, o ESTRA, projetado exclusivamente para esse fim. Mostra-se como a pesquisa de corpora do ESTRA promove a interdisciplinaridade nos estudos da tradução e introduz a triangulação de resultados de análises realizadas com procedimentos metodológicos das diferentes abordagens usadas para estudar o estilo. Descrevem-se procedimentos metodológicos novos, em especial a etiquetagem do corpus para algumas das categorias de estilo. Termina-se o artigo com uma visão crítica sobre o que tem sido feito até o presente, apresentando perspectivas futuras de pesquisa em estilística tradutória no LETRA.

  9. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  10. Self-calibrating quantum state tomography

    International Nuclear Information System (INIS)

    Brańczyk, A M; Mahler, D H; Rozema, L A; Darabi, A; Steinberg, A M; James, D F V

    2012-01-01

    We introduce and experimentally demonstrate a technique for performing quantum state tomography (QST) on multiple-qubit states despite incomplete knowledge about the unitary operations used to change the measurement basis. Given unitary operations with unknown rotation angles, our method can be used to reconstruct the density matrix of the state up to local σ z rotations as well as recover the magnitude of the unknown rotation angle. We demonstrate high-fidelity self-calibrating tomography on polarization-encoded one- and two-photon states. The unknown unitary operations are realized in two ways: using a birefringent polymer sheet—an inexpensive smartphone screen protector—or alternatively a liquid crystal wave plate with a tuneable retardance. We explore how our technique may be adapted for QST of systems such as biological molecules where the magnitude and orientation of the transition dipole moment is not known with high accuracy. (paper)

  11. Self-calibrating quantum state tomography

    Energy Technology Data Exchange (ETDEWEB)

    Branczyk, A M; Mahler, D H; Rozema, L A; Darabi, A; Steinberg, A M; James, D F V, E-mail: branczyk@physics.utoronto.ca [CQIQC and IOS, Department of Physics, University of Toronto, 60 Saint George Street, Toronto, Ontario, M5S 1A7 (Canada)

    2012-08-15

    We introduce and experimentally demonstrate a technique for performing quantum state tomography (QST) on multiple-qubit states despite incomplete knowledge about the unitary operations used to change the measurement basis. Given unitary operations with unknown rotation angles, our method can be used to reconstruct the density matrix of the state up to local {sigma}{sub z} rotations as well as recover the magnitude of the unknown rotation angle. We demonstrate high-fidelity self-calibrating tomography on polarization-encoded one- and two-photon states. The unknown unitary operations are realized in two ways: using a birefringent polymer sheet-an inexpensive smartphone screen protector-or alternatively a liquid crystal wave plate with a tuneable retardance. We explore how our technique may be adapted for QST of systems such as biological molecules where the magnitude and orientation of the transition dipole moment is not known with high accuracy. (paper)

  12. Inherent Limitations of Hydraulic Tomography

    Science.gov (United States)

    Bohling, Geoffrey C.; Butler, J.J.

    2010-01-01

    We offer a cautionary note in response to an increasing level of enthusiasm regarding high-resolution aquifer characterization with hydraulic tomography. We use synthetic examples based on two recent field experiments to demonstrate that a high degree of nonuniqueness remains in estimates of hydraulic parameter fields even when those estimates are based on simultaneous analysis of a number of carefully controlled hydraulic tests. We must, therefore, be careful not to oversell the technique to the community of practicing hydrogeologists, promising a degree of accuracy and resolution that, in many settings, will remain unattainable, regardless of the amount of effort invested in the field investigation. No practically feasible amount of hydraulic tomography data will ever remove the need to regularize or bias the inverse problem in some fashion in order to obtain a unique solution. Thus, along with improving the resolution of hydraulic tomography techniques, we must also strive to couple those techniques with procedures for experimental design and uncertainty assessment and with other more cost-effective field methods, such as geophysical surveying and, in unconsolidated formations, direct-push profiling, in order to develop methods for subsurface characterization with the resolution and accuracy needed for practical field applications. Copyright ?? 2010 The Author(s). Journal compilation ?? 2010 National Ground Water Association.

  13. Linfadenocromatografia perigástrica com carbono ativado (CH40: estudo experimental Perigastric lymphadenochromatography with activated carbon (CH40: experimental study

    Directory of Open Access Journals (Sweden)

    Minao Okawa

    2007-09-01

    Full Text Available RACIONAL: Procedimento cirúrgico bem instituído e planejado constitui ainda a única terapêutica efetiva para o câncer gástrico. Entretanto, os resultados de cura não têm melhorado significativamente nas últimas décadas, principalmente no ocidente. O principal benefício de introdução endoscópica de corantes na submucosa gástrica está na facilitação de linfadenectomias regradas, podendo facilitar a localização acurada dos linfonodos. Além disso, a linfadenocromatografia possibilita futuras pesquisas para a detecção do linfonodo sentinela e sua aplicabilidade racional e seletiva na indicação precisa da linfadenectomia, principalmente dos grupos de linfonodos de ressecção mais trabalhosa e com maiores possibilidades de complicações. A linfadenocromatografia com carbono ativado (CH40 foi analisada neste estudo experimental (fase 1. OBJETIVOS: Testar a efetividade e inocuidade da linfadenocromatografia com CH40, em três espécies animais diferentes. MÉTODOS: Como preconizado pela Associação Brasileira de Pesquisas Clínicas (Resoluções nº 196/96 e 251/97, CNS/MS, foram utilizados três espécies diferentes de animais: 3 cães, 10 coelhos e 20 ratos. Em todos os cães, a introdução de CH40 na camada submucosa de estômago foi realizada através da endoscopia gástrica e utilizando, cateter de polietileno agulhado, usualmente empregado na esclerose de varizes esofageanas. O período de observação variou de 43 a 125 dias, quando o procedimento cirúrgico foi realizado. Em todos os coelhos e ratos a introdução de CH40 foi realizada através de agulha hipodérmica e seringa insulínica, na região subcutânea inguinal. O período de observação foi de 102 a 105 dias e 110 a 122 dias, respectivamente. RESULTADOS: Nos períodos de observação, desde a injeção até a eutanásia, não se detectou em nenhum animal efeito colateral ou óbito. Nos cães, linfonodos perigástricos foram corados pelo CH40. Em todos os

  14. Nano-Tomography of Porous Geological Materials Using Focused Ion Beam-Scanning Electron Microscopy

    Directory of Open Access Journals (Sweden)

    Yang Liu

    2016-10-01

    Full Text Available Tomographic analysis using focused ion beam-scanning electron microscopy (FIB-SEM provides three-dimensional information about solid materials with a resolution of a few nanometres and thus bridges the gap between X-ray and transmission electron microscopic tomography techniques. This contribution serves as an introduction and overview of FIB-SEM tomography applied to porous materials. Using two different porous Earth materials, a diatomite specimen, and an experimentally produced amorphous silica layer on olivine, we discuss the experimental setup of FIB-SEM tomography. We then focus on image processing procedures, including image alignment, correction, and segmentation to finally result in a three-dimensional, quantified pore network representation of the two example materials. To each image processing step we consider potential issues, such as imaging the back of pore walls, and the generation of image artefacts through the application of processing algorithms. We conclude that there is no single image processing recipe; processing steps need to be decided on a case-by-case study.

  15. Optical tomography of tissues

    International Nuclear Information System (INIS)

    Zimnyakov, D A; Tuchin, Valerii V

    2002-01-01

    Methods of optical tomography of biological tissues are considered, which include pulse-modulation and frequency-modulation tomography, diffusion tomography with the use of cw radiation sources, optical coherent tomography, speckle-correlation tomography of nonstationary media, and optoacoustic tomography. The method for controlling the optical properties of tissues is studied from the point of view of increasing a probing depth in optical coherent tomography. The modern state and prospects of the development of optical tomography are discussed. (review)

  16. Wigner tomography of multispin quantum states

    Science.gov (United States)

    Leiner, David; Zeier, Robert; Glaser, Steffen J.

    2017-12-01

    We study the tomography of multispin quantum states in the context of finite-dimensional Wigner representations. An arbitrary operator can be completely characterized and visualized using multiple shapes assembled from linear combinations of spherical harmonics [A. Garon, R. Zeier, and S. J. Glaser, Phys. Rev. A 91, 042122 (2015), 10.1103/PhysRevA.91.042122]. We develop a general methodology to experimentally recover these shapes by measuring expectation values of rotated axial spherical tensor operators and provide an interpretation in terms of fictitious multipole potentials. Our approach is experimentally demonstrated for quantum systems consisting of up to three spins using nuclear magnetic resonance spectroscopy.

  17. Quantitative X-ray dark-field and phase tomography using single directional speckle scanning technique

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hongchang, E-mail: hongchang.wang@diamond.ac.uk; Kashyap, Yogesh; Sawhney, Kawal [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom)

    2016-03-21

    X-ray dark-field contrast tomography can provide important supplementary information inside a sample to the conventional absorption tomography. Recently, the X-ray speckle based technique has been proposed to provide qualitative two-dimensional dark-field imaging with a simple experimental arrangement. In this letter, we deduce a relationship between the second moment of scattering angle distribution and cross-correlation degradation of speckle and establish a quantitative basis of X-ray dark-field tomography using single directional speckle scanning technique. In addition, the phase contrast images can be simultaneously retrieved permitting tomographic reconstruction, which yields enhanced contrast in weakly absorbing materials. Such complementary tomography technique can allow systematic investigation of complex samples containing both soft and hard materials.

  18. Avaliação do efeito da glicosamina e condroitina na consolidação de fratura: estudo experimental em ratos Evaluating the effects of glucosamine and chondroitin in bone healing: experimental study in rats

    Directory of Open Access Journals (Sweden)

    Roberto Guarniero

    2007-07-01

    Full Text Available OBJETIVO: Avaliar o efeito da administração da condroitina e da glicosamina na consolidação de fratura em modelo animal. MÉTODOS: Este estudo experimental envolveu a utilização de 40 ratos machos adultos da raça Lewis. Os animais foram randomicamente divididos em quatro grupos de 10 animais cada, assim constituídos: grupo I, com administração de glicosamina; grupo II, com administração de condroitina; grupo III, administração da associação de glicosamina e condroitina; grupo IV, administração de água destilada (grupo controle. Realizou-se uma fratura fechada médio-diafisária da tíbia e fíbula direitas em cada animal, seguida da administração diária das drogas de acordo com o grupo, durante 30 dias. Após esse período, os animais foram sacrificados para estudo dos calos ósseos formados. Os critérios de avaliação foram a avaliação clínica da consolidação óssea, mensuração da densidade mineral do calo ósseo utilizando-se a densitometria óssea e cálculo da área do calo formado por meio de planigrafia. Os dados coletados foram avaliados com a técnica da análise de variância (ANOVA para verificar diferenças entre as médias nos quatro grupos estudados e com o teste de Tukey para comparação das médias duas a duas. Adotou-se nível de significância de 5% (alfa = 0,05. RESULTADOS: A utilização da condroitina e da glicosamina, tanto de maneira isolada quanto associadas, não resultou em aumento da área do calo ósseo ou da sua densidade mineral óssea, e não havendo melhora clínica da consolidação óssea. CONCLUSÃO: A administração de condroitina e glicosamina, neste estudo, não influenciou - quer de maneira positiva ou negativa - a consolidação de fraturas experimentais em ratos.OBJECTIVE: To evaluate the effects of administering chondroitin and glucosamine for bone healing in an animal model. METHODS: This experimental study involved the use of 50 male adult Lewis rats. The animals were

  19. An experimental platform for triaxial high-pressure/high-temperature testing of rocks using computed tomography

    Science.gov (United States)

    Glatz, Guenther; Lapene, Alexandre; Castanier, Louis M.; Kovscek, Anthony R.

    2018-04-01

    A conventional high-pressure/high-temperature experimental apparatus for combined geomechanical and flow-through testing of rocks is not X-ray compatible. Additionally, current X-ray transparent systems for computed tomography (CT) of cm-sized samples are limited to design temperatures below 180 °C. We describe a novel, high-temperature (>400 °C), high-pressure (>2000 psi/>13.8 MPa confining, >10 000 psi/>68.9 MPa vertical load) triaxial core holder suitable for X-ray CT scanning. The new triaxial system permits time-lapse imaging to capture the role of effective stress on fluid distribution and porous medium mechanics. System capabilities are demonstrated using ultimate compressive strength (UCS) tests of Castlegate sandstone. In this case, flooding the porous medium with a radio-opaque gas such as krypton before and after the UCS test improves the discrimination of rock features such as fractures. The results of high-temperature tests are also presented. A Uintah Basin sample of immature oil shale is heated from room temperature to 459 °C under uniaxial compression. The sample contains kerogen that pyrolyzes as temperature rises, releasing hydrocarbons. Imaging reveals the formation of stress bands as well as the evolution and connectivity of the fracture network within the sample as a function of time.

  20. Atom Probe Tomography of Phase and Grain Boundaries in Experimentally-Deformed and Hot-Pressed Wehrlite

    Science.gov (United States)

    Cukjati, J.; Parman, S. W.; Cooper, R. F.; Zhao, N.

    2017-12-01

    Atom probe tomography (APT) was used to characterize the chemistry of three grain boundaries: an olivine-olivine (ol-ol) and olivine-clinopyroxene (ol-cpx) boundary in fine-grained experimentally-deformed wehrlite and an ol-cpx boundary in a fine-grained, hot-pressed wehrlite. Grain boundaries were extracted and formed into APT tips using a focused ion beam (FIB). The tips were analyzed in a reflectron-equipped LEAP4000HR (Harvard University) at 1% or 0.5% detection rate, 5pJ laser energy and 100kHz pulse rate. Total ion counts are between 40 and 100 million per tip. Examination of grain and phase boundaries in wehrlite are of interest since slow-diffusing and olivine-incompatible cations present in cpx (e.g. Ca and Al) may control diffusion-accommodated grain boundary sliding and affect mantle rheology (Sundberg & Cooper, 2008). At steady state, ol-cpx aggregates are weaker than either ol or cpx end member, the results of which are not currently well-explained. We investigate grain boundary widths to understand the transport of olivine-incompatible elements. Widths of grain/phase boundary chemical segregation are between 3nm and 6nm for deformed ol-ol and ol-cpx samples; minimally-deformed (hot-pressed) samples having slightly wider chemical segregation widths. Chemical segregation widths were determined from profiles of Na, Al, P, Cl, K, Ca, or Ni, although not all listed elements can be used for all samples (e.g. Na, K segregation profiles can only be observed for ol-ol sample). These estimates are consistent with prior estimates of grain boundary segregation by atom probe tomography on ol-ol and opx-opx samples (Bachhav et al., 2015) and are less than ol-ol interface widths analyzed by STEM/EDX (Hiraga, Anderson, & Kohlstedt, 2007). STEM/EDX will be performed on deformed wehrlite to investigate chemical profile as a function of applied stress orientation and at length scales between those observable by APT and EPMA. Determination of phase boundary chemistry and

  1. Uma ferramenta para planejamento de estudos para concursos

    Directory of Open Access Journals (Sweden)

    Leonardo Pimentel

    2015-11-01

    Full Text Available De acordo com a constituição brasileira, a única forma de se tornar um empregado do governo é passar em um concurso público. O exame de conhecimento do cargo é um dos componentes mais importantes de um concurso. Estudar para esse exame é uma tarefa que requer planejamento. Um meio de obter um bom planejamento é construir uma grade de horários que relacione as matérias a serem estudadas com os respectivos horários disponíveis para o estudo. Esse tipo de problema se assemelha bastante à gerência de projetos, em que se procura estabelecer a distribuição das atividades ao longo do tempo disponível. Assim, torna-se interessante explorar a dinâmica de estudos para concursos como um projeto. O presente trabalho apresenta a ferramenta de apoio ao estudos - Passe-me, baseada no ciclo PDCA (do inglês, Plan-Do-Check-Act. Por se tratar de uma ferramenta web, o tempo de resposta para produzir uma grade de estudos é fundamental. A ferramenta faz uso de algoritmo genético para calcular a grade de horários priorizando a velocidade de resposta. A ferramenta foi avaliada em diferentes cenários de uso e obteve desempenho satisfatório durante a produção da grade de estudos.

  2. Experimental investigation of surface determination process on multi-material components for dimensional computed tomography

    DEFF Research Database (Denmark)

    Borges de Oliveira, Fabrício; Stolfi, Alessandro; Bartscher, Markus

    2016-01-01

    The possibility of measuring multi-material components, while assessing inner and outer features simultaneously makes X-ray computed tomography (CT) the latest evolution in the field of coordinate measurement systems (CMSs). However, the difficulty in selecting suitable scanning parameters and su...

  3. Computerized tomography

    International Nuclear Information System (INIS)

    Rubashov, I.B.

    1985-01-01

    Operating principle is described for the devices of computerized tomography used in medicine for diagnosis of brain diseases. Computerized tomography is considered as a part of computerized diagnosis, as a part of information science. It is shown that computerized tomography is a real existed field of investigations in medicine and industrial production

  4. Efeito da desnutrição na cicatrização de anastomoses colônicas: estudo experimental em ratos Effects of malnutrition on colonic anastomosis healing: an experimental study in rats

    Directory of Open Access Journals (Sweden)

    Manuela Molina Ferreira

    2006-09-01

    Full Text Available A deiscência de anastomose é uma das mais graves complicações advindas de operações do tubo gastrintestinal. Algumas condições gerais podem prejudicar o processo de cicatrização, tais como: desnutrição e hipoalbuminemia. Este estudo experimental teve como objetivo avaliar a cicatrização de anastomoses colônicas na vigência de desnutrição protéico-calórica e hipoalbuminemia. Dividimos os animais em dois grupos, sendo um deles o controle e o outro desnutrido (ingestão diária de metade da ração do grupo controle por vinte dias. O peso corporal, a albumina sérica, a evolução clínica, a cavidade abdominal, os aspectos macro e microscópicos da anastomose, a esteatose hepática e a concentração tecidual de hidroxiprolina foram observadas em cada animal. Pudemos notar que o método utilizado para desnutrir os animais mostrou-se eficaz, uma vez que houve redução significativa do peso do grupo experimental. Observamos que o grupo desnutrido apresentou dados necroscópicos de pior prognóstico e mortalidade superior ao grupo controle. Concluímos que a desnutrição influencia negativamente na cicatrização de anastomoses colônicas e aumenta significativamente a mortalidade.Dehiscence of colonic anastomosis is one of the most severe complications after gastrointestinal surgery. The intestinal anastomosis healing complication is associated to several factors like malnutrition and hypoalbuminemia. This is an experimental study that aimed to evaluate the colonic anastomosis healing in malnutrition and hypoalbuminemia conditions. Animals were separated in two experimental groups: control and submitted to malnutrition (daily food intake as half of the control group per 20 days. Body weight, clinical outcome, serum albumin, abdominal cavity aspects, gross and microscopic aspects of the anastomosis, hepatic steatosis and tissue hydroxyproline dosage were compared between groups. Our results show that malnutrition development was

  5. Debates críticos: os Estudos de Segurança e o futuro dos Estudos da Paz e dos Conflitos 10.5102/uri.v11i2.2526

    Directory of Open Access Journals (Sweden)

    André Barrinha

    2013-11-01

    Full Text Available Irremediavelmente ligados pela proximidade dos respetivos objetos de estudo, Estudos de Segurança e Estudos da Paz e dos Conflitos constituíram-se e evoluíram ao longo da Guerra Fria como disciplinas antagónicas. Essa divisão operou-se sobretudo na Europa, onde Galtung e seus discípulos encaminharam o estudo das questões da guerra e da paz para uma agenda claramente normativa e crítica, enquanto o estudo das questões de segurança se centrava numa abordagem orientada para o policy-making. Como é defendido neste artigo, o final do conflito bipolar correspondeu, até certo ponto, a uma inversão de papéis, com os Estudos da Paz e dos Conflitos acomodados a um empirismo desprovido de normatividade e os Estudos de Segurança, pelo menos na Europa, a abrirem-se a novas abordagens de cariz mais crítico. É aqui sugerido que esta inversão contém, em si, importantes lições para os Estudos da Paz e da Segurança, nomeadamente sobre a centralidade da teoria na definição de uma nova agenda crítica que permita uma aproximação entre as duas disciplinas.

  6. Optical coherence tomography in conjunction with bronchoscopy

    International Nuclear Information System (INIS)

    Rodrigues, Ascedio Jose; Takimura, Celso Kiyochi; Lemos Neto, Pedro Alves; Figueiredo, Viviane Rossi

    2012-01-01

    To evaluate the feasibility of and the potential for using optical coherence tomography in conjunction with conventional bronchoscopy in the evaluation of the airways. Methods: This was a pilot study based on an ex vivo experimental model involving three animals: one adult New Zealand rabbit and two Landrace pigs. An optical coherence tomography imaging catheter was inserted through the working channel of a flexible bronchoscope in order to reach the distal trachea of the animals. Images of the walls of the trachea were systematically taken along its entire length, from the distal to the proximal portion. Results: The imaging catheter was easily adapted to the working channel of the bronchoscope. High-resolution images of cross sections of the trachea were taken in real time, precisely delineating microstructures, such as the epithelium, submucosa, and cartilage, as well as the adventitia of the anterior and lateral tracheal walls. The corresponding layers of the epithelium, mucosa, and cartilage were clearly differentiated. The mucosa, submucosa, and trachealis muscle were clearly identified in the posterior wall. Conclusions: It is feasible to use an optical coherence tomography imaging catheter in combination with a flexible bronchoscope. Optical coherence tomography produces high resolution images that reveal the microanatomy of the trachea, including structures that are typically seen only on images produced by conventional histology. (author)

  7. Optical coherence tomography in conjunction with bronchoscopy

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Ascedio Jose; Takimura, Celso Kiyochi; Lemos Neto, Pedro Alves; Figueiredo, Viviane Rossi, E-mail: ascedio@gmail.com [Servico de Endoscopia Respiratoria, Hospital das Clinicas, Universidade de Sao Paulo (FM/USP), SP (Brazil)

    2012-07-01

    To evaluate the feasibility of and the potential for using optical coherence tomography in conjunction with conventional bronchoscopy in the evaluation of the airways. Methods: This was a pilot study based on an ex vivo experimental model involving three animals: one adult New Zealand rabbit and two Landrace pigs. An optical coherence tomography imaging catheter was inserted through the working channel of a flexible bronchoscope in order to reach the distal trachea of the animals. Images of the walls of the trachea were systematically taken along its entire length, from the distal to the proximal portion. Results: The imaging catheter was easily adapted to the working channel of the bronchoscope. High-resolution images of cross sections of the trachea were taken in real time, precisely delineating microstructures, such as the epithelium, submucosa, and cartilage, as well as the adventitia of the anterior and lateral tracheal walls. The corresponding layers of the epithelium, mucosa, and cartilage were clearly differentiated. The mucosa, submucosa, and trachealis muscle were clearly identified in the posterior wall. Conclusions: It is feasible to use an optical coherence tomography imaging catheter in combination with a flexible bronchoscope. Optical coherence tomography produces high resolution images that reveal the microanatomy of the trachea, including structures that are typically seen only on images produced by conventional histology. (author)

  8. Quantum tomography for collider physics. Illustrations with lepton-pair production

    Energy Technology Data Exchange (ETDEWEB)

    Martens, John C.; Ralston, John P.; Takaki, J.D.T. [The University of Kansas, Department of Physics and Astronomy, Lawrence, KS (United States)

    2018-01-15

    Quantum tomography is a method to experimentally extract all that is observable about a quantum mechanical system. We introduce quantum tomography to collider physics with the illustration of the angular distribution of lepton pairs. The tomographic method bypasses much of the field-theoretic formalism to concentrate on what can be observed with experimental data. We provide a practical, experimentally driven guide to model-independent analysis using density matrices at every step. Comparison with traditional methods of analyzing angular correlations of inclusive reactions finds many advantages in the tomographic method, which include manifest Lorentz covariance, direct incorporation of positivity constraints, exhaustively complete polarization information, and new invariants free from frame conventions. For example, experimental data can determine the entanglement entropy of the production process. We give reproducible numerical examples and provide a supplemental standalone computer code that implements the procedure. We also highlight a property of complex positivity that guarantees in a least-squares type fit that a local minimum of a χ{sup 2} statistic will be a global minimum: There are no isolated local minima. This property with an automated implementation of positivity promises to mitigate issues relating to multiple minima and convention dependence that have been problematic in previous work on angular distributions. (orig.)

  9. Quantum tomography for collider physics: illustrations with lepton-pair production

    Science.gov (United States)

    Martens, John C.; Ralston, John P.; Takaki, J. D. Tapia

    2018-01-01

    Quantum tomography is a method to experimentally extract all that is observable about a quantum mechanical system. We introduce quantum tomography to collider physics with the illustration of the angular distribution of lepton pairs. The tomographic method bypasses much of the field-theoretic formalism to concentrate on what can be observed with experimental data. We provide a practical, experimentally driven guide to model-independent analysis using density matrices at every step. Comparison with traditional methods of analyzing angular correlations of inclusive reactions finds many advantages in the tomographic method, which include manifest Lorentz covariance, direct incorporation of positivity constraints, exhaustively complete polarization information, and new invariants free from frame conventions. For example, experimental data can determine the entanglement entropy of the production process. We give reproducible numerical examples and provide a supplemental standalone computer code that implements the procedure. We also highlight a property of complex positivity that guarantees in a least-squares type fit that a local minimum of a χ 2 statistic will be a global minimum: There are no isolated local minima. This property with an automated implementation of positivity promises to mitigate issues relating to multiple minima and convention dependence that have been problematic in previous work on angular distributions.

  10. Estudo experimental da biocompatibilidade de novo material para implante orbitário

    Directory of Open Access Journals (Sweden)

    Rodrigo Beraldi Kormann

    2013-06-01

    Full Text Available OBJETIVO:Avaliar a biocompatibilidade de material FullCure 720®, que é uma resina, na confecção de implante orbitário. Avaliou-se a resposta clínica dos animais, toxicidade sistêmica e a resposta inflamatória crônica. Os animais foram pesados, exames bioquímicos e resposta inflamatória foram avaliados. Foi efetuada evisceração e colocado implante esférico orbitário. Os animais foram acompanhados durante o período de 60 dias, onde se avaliou o comportamento clínico e sinais locais. Após este período, procedeu-se a eutanásia seguida da enucleação. Foi realizada análise macroscópica e histomorfométrica. Os resultados revelaram comportamento normal dos animais, com ausência de exposição ou extrusão dos implantes, morte de algum animal e ausência de toxicidade sistêmica. Houve formação de uma cápsula fibrosa entre a capa escleral e o implante orbitário, resposta inflamatória considerada normal quando em contato com o tecido do coelho. A resina FullCure 720® utilizada como implante orbitário, mostrou-se biocompatível neste estudo.

  11. Experimental investigation of bone mineral density in Thoroughbreds using quantitative computed tomography

    OpenAIRE

    YAMADA, Kazutaka; SATO, Fumio; HIGUCHI, Tohru; NISHIHARA, Kaori; KAYANO, Mitsunori; SASAKI, Naoki; NAMBO, Yasuo

    2015-01-01

    ABSTRACT Bone mineral density (BMD) is one of the indications of the strength and health. BMD measured by quantitative computed tomography (QCT) was compared with that measured by dual energy X-ray absorptiometry (DXA) and radiographic bone aluminum equivalence (RBAE). Limbs were removed from horses that had been euthanized for reasons not associated with this study. Sixteen limbs (left and right metacarpals and metatarsals) from 4 horses were used to compare BMD as measured by QCT with those...

  12. Experimental investigation of bone mineral density in Thoroughbreds using quantitative computed tomography

    OpenAIRE

    Yamada, Kazutaka; Sato, Fumio; Higuchi, Tohru; Nishihara, Kaori; Kayano, Mitsunori; Sasaki, Naoki; Nambo, Yasuo

    2015-01-01

    Bone mineral density (BMD) is one of the indications of the strength and health. BMD measured by quantitative computed tomography (QCT) was compared with that measured by dual energy X-ray absorptiometry (DXA) and radiographic bone aluminum equivalence (RBAE). Limbs were removed from horses that had been euthanized for reasons not associated with this study. Sixteen limbs (left and right metacarpals and metatarsals) from 4 horses were used to compare BMD as measured by QCT with those measured...

  13. Anastomose mecanica em reto extraperitoneal : (duas tecnicas de reconstrução) : estudo experimental comparativo em caes

    OpenAIRE

    Fernando Cordeiro

    1995-01-01

    Resumo: Os problemas resultantes das anastomoses no reto abaixo da reflexão peritoneal continuam sendo tema de discussões. Com o desenvolvimento de novas técnicas pode-se estender a ressecção anterior aos segmentos retais mais baixos com preservação do mecanismo esfincteriano, porém a segurança destes procedimentos está por ser estabelecida. Este estudo comparativo randomizado entre duas técnicas de anastomose mecânica no reto de cães, abaixo da reflexão peritoneal, permitiu a elaboração de...

  14. Fuzzy modeling of electrical impedance tomography images of the lungs

    International Nuclear Information System (INIS)

    Tanaka, Harki; Ortega, Neli Regina Siqueira; Galizia, Mauricio Stanzione; Borges, Joao Batista; Amato, Marcelo Britto Passos

    2008-01-01

    Objectives: Aiming to improve the anatomical resolution of electrical impedance tomography images, we developed a fuzzy model based on electrical impedance tomography's high temporal resolution and on the functional pulmonary signals of perfusion and ventilation. Introduction: Electrical impedance tomography images carry information about both ventilation and perfusion. However, these images are difficult to interpret because of insufficient anatomical resolution, such that it becomes almost impossible to distinguish the heart from the lungs. Methods: Electrical impedance tomography data from an experimental animal model were collected during normal ventilation and apnoea while an injection of hypertonic saline was administered. The fuzzy model was elaborated in three parts: a modeling of the heart, the pulmonary ventilation map and the pulmonary perfusion map. Image segmentation was performed using a threshold method, and a ventilation/perfusion map was generated. Results: Electrical impedance tomography images treated by the fuzzy model were compared with the hypertonic saline injection method and computed tomography scan images, presenting good results. The average accuracy index was 0.80 when comparing the fuzzy modeled lung maps and the computed tomography scan lung mask. The average ROC curve area comparing a saline injection image and a fuzzy modeled pulmonary perfusion image was 0.77. Discussion: The innovative aspects of our work are the use of temporal information for the delineation of the heart structure and the use of two pulmonary functions for lung structure delineation. However, robustness of the method should be tested for the imaging of abnormal lung conditions. Conclusions: These results showed the adequacy of the fuzzy approach in treating the anatomical resolution uncertainties in electrical impedance tomography images. (author)

  15. Prediction of traumatic avascular necrosis of the femoral head by single photon emission computerized tomography and computerized tomography: an experimental study in dogs

    Directory of Open Access Journals (Sweden)

    SHEN Feng

    2012-02-01

    Full Text Available 【Abstract】 Objective: To evaluate the femoral head perfusion and to predict the traumatic avascular necrosis (AVN of the femoral head by single photon emission computerized tomography and computerized tomography (SPECT/CT. Methods: Totally 18 adult beagle dogs were divided randomly into three equal-sized (n=6 groups. Subsequently different degrees of ischemia model were developed by destroying blood vessels of the femoral head. The left hip received sham operation as normal control and the right hip underwent blood interruption. In Group A, the ligamentum teres was cut off. In Group B, the marrow cavity of the right femoral neck was destroyed while in Group C, the soft tissues at the base of the femoral neck were stripped in addition to the resection of the ligamentum teres and destruction of the marrow cavity. Three hours after surgery, SPECT/CT was performed. Laser Doppler Flowmetry (LDF measurements were also obtained at three different time points (before operation, immediately and three hours after operation in order to assess the change process of blood supply to the femoral head. Results: SPECT/CT showed no significant difference in the radionuclide uptake between the right and left femoral heads in Group A (t=-0.09, P=0.94 and Group B (t= 0.52, P=0.62. However, in Group C, it was 261±62 for the right femoral head, only 12% of that in the left femoral head. LDF measurements indicated that the femoral head perfusion was decreased from (45.0±3.3 PU to (39.1±3.7 PU in Group A, from (44.0±2.7 PU to (34.3±2.6 PU in Group B, and from (47.3±2.1 PU to (4.96±0.6 PU in Group C immediately after operation. However, the perfusion was restored and returned to normal values three hours after operation except in Group C. Conclusion: SPECT/CT could assess the perfusion of the femoral head semiquantitatively, which might be useful in predicting the development of traumatic AVN. Key words: Femur head necrosis; Femoral head; Tomography, emission

  16. Noise reduction in muon tomography for detecting high density objects

    International Nuclear Information System (INIS)

    Benettoni, M; Checchia, P; Cossutta, L; Furlan, M; Gonella, F; Pegoraro, M; Garola, A Rigoni; Ronchese, P; Vanini, S; Viesti, G; Bettella, G; Bonomi, G; Donzella, A; Subieta, M; Zenoni, A; Calvagno, G; Cortelazzo, G; Zanuttigh, P; Calvini, P; Squarcia, S

    2013-01-01

    The muon tomography technique, based on multiple Coulomb scattering of cosmic ray muons, has been proposed as a tool to detect the presence of high density objects inside closed volumes. In this paper a new and innovative method is presented to handle the density fluctuations (noise) of reconstructed images, a well known problem of this technique. The effectiveness of our method is evaluated using experimental data obtained with a muon tomography prototype located at the Legnaro National Laboratories (LNL) of the Istituto Nazionale di Fisica Nucleare (INFN). The results reported in this paper, obtained with real cosmic ray data, show that with appropriate image filtering and muon momentum classification, the muon tomography technique can detect high density materials, such as lead, albeit surrounded by light or medium density material, in short times. A comparison with algorithms published in literature is also presented

  17. Pensamento, Teoria e Estudos Latino-americanos

    Directory of Open Access Journals (Sweden)

    Jacques de Novion

    2014-12-01

    Full Text Available RESUMO O presente trabalho configura como artigo inicial do Dossiê Especial – Pensamento, Teoria e Estudos Latino-americanos, organizado conjuntamente por nós, a pedido da Revista de Estudos e Pesquisas sobre as Américas (CEPPAC, do Instituto de Ciências Sociais (ICS, da Universidade de Brasília (UnB. De forma breve, este artigo apresenta a importância alcançada pelo Pensamento, pela Teoria, e, sobre tudo, pelos Estudos Latino-americanos nas últimas décadas. Em seguida, o artigo apresenta os quatorze trabalhos e uma resenha que compõem este Dossiê, resultado da contribuição de diferentes pesquisadores de distintas localidades da região, organizados em três blocos: Ciências Sociais Latino-americanas, Pensamento e Estudos. PALAVRAS CHAVE: Ciências Sociais Latino-americanas; Pensamento Latino-americanos; Teoria Latino-americana; Estudos Latino-americanos. --- RESUMEN El presente trabajo configura como articulo inicial del Dossier Especial – Pensamiento Teoría y Estudios Latinoamericanos, organizado conjuntamente por nosotros, a pedido de la Revista de Estudos e Pesquisas sobre as Américas (CEPPAC, del Instituto de Ciências Sociais (ICS, de la Universidade de Brasília (UnB. De forma breve, este articulo presenta la importancia alcanzada por el Pensamiento, por la Teoría, y, sobre todo, por los Estudios Latinoamericanos en las últimas décadas. En seguida, el articulo presenta los catorce trabajos e una reseña que componen este Dossier, resultado de la contribución de diferentes investigadores de distintas localidades de la región, organizados en tres bloques: Ciencias Sociales Latinoamericanas, Pensamiento y Estudios. PALABRAS CLAVE: Ciencias Sociales Latinoamericanas; Pensamiento Latinoamericano; Teoría Latinoamericana; Estudios Latinoamericanos. --- ABSTRACT This paper is set up as the initial article of this Special Dossier - Thought, Theory and Latin American Studies, which we organized collectively, at the request

  18. Quantitative imaging of magnetic nanoparticles by magneto-relaxometric tomography for biomedical applications; Quantitative Bildgebung magnetischer Nanopartikel mittels magnetrelaxometrischer Tomographie fuer biomedizinische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Liebl, Maik

    2016-11-18

    Current biomedical research focuses on the development of novel biomedical applications based on magnetic nanoparticles (MNPs), e.g. for local cancer treatment. These therapy approaches employ MNPs as remotely controlled drug carriers or local heat generators. Since location and quantity of MNPs determine drug enrichment and heat production, quantitative knowledge of the MNP distribution inside a body is essential for the development and success of these therapies. Magnetorelaxometry (MRX) is capable to provide such quantitative information based on the specific response of the MNPs after switching-off an applied magnetic field. Applying a uniform (homogeneous) magnetic field to a MNP distribution and measuring the MNP response by multiple sensors at different locations allows for spatially resolved MNP quantification. However, to reconstruct the MNP distribution from this spatially resolved MRX data, an ill posed inverse problem has to be solved. So far, the solution of this problem was stabilized incorporating a-priori knowledge in the forward model, e.g. by setting priors on the vertical position of the distribution using a 2D reconstruction grid or setting priors on the number and geometry of the MNP sources inside the body. MRX tomography represents a novel approach for quantitative 3D imaging of MNPs, where the inverse solution is stabilized by a series of MRX measurements. In MRX tomography, only parts of the MNP distribution are sequentially magnetized by the use of inhomogeneous magnetic fields. Each magnetizing is followed by detection of the response of the corresponding part of the distribution by multiple sensors. The 3D reconstruction of the MNP distribution is then accomplished by a common evaluation of the distinct MRX measurement series. In this thesis the first experimental setup for MRX tomography was developed for quantitative 3D imaging of biomedical MNP distributions. It is based on a multi-channel magnetizing unit which has been engineered to

  19. Desafios dos Estudos Gays, Lésbicos e Transgêneros

    Directory of Open Access Journals (Sweden)

    Denilson Lopes

    2008-09-01

    Full Text Available Resumo: Este ensaio introduz algumas questões relativas aos estudos feministas, gays, lésbicos, transgênecos e teoria queer na busca de contribuições teórico-metodológicas na análise da cultura contemporânea. Palavras-chave: Estudos gays e lésbicos, estudos transgêneros, teoria queer, cultura. Abstrat: This essay introduces some issues related tofeminist studies, gay and lesbian studies, transgender studies and queer theory in the search of theoretical and methodological contributions in the analysis of contemporary culture. Key-words: Gay and Lesbian Studies, transgender studies, queer theory, culture

  20. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  1. Design and characterization of a small muon tomography system

    Science.gov (United States)

    Jo, Woo Jin; An, Su Jung; Kim, Hyun-Il; Lee, Chae Young; Chung, Heejun; Chung, Yong Hyun

    2015-02-01

    Muon tomography is a useful method for monitoring special nuclear materials (SNMs) because it can provide effective information on the presence of high-Z materials, has a high enough energy to deeply penetrate large amounts of shielding, and does not lead to any health risks and danger above background. We developed a 2-D muon detector and designed a muon tomography system employing four detector modules. Two top and two bottom detectors are, respectively, employed to record the incident and the scattered muon trajectories. The detector module for the muon tomography system consists of a plastic scintillator, wavelength-shifting (WLS) fiber arrays placed orthogonally on the top and the bottom of the scintillator, and a position-sensitive photomultiplier (PSPMT). The WLS fiber arrays absorb light photons emitted by the plastic scintillator and re-emit green lights guided to the PSPMT. The light distribution among the WLS fiber arrays determines the position of the muon interaction; consequently, 3-D tomographic images can be obtained by extracting the crossing points of the individual muon trajectories by using a point-of-closest-approach algorithm. The goal of this study is to optimize the design parameters of a muon tomography system by using the Geant4 code and to experimentally evaluate the performance of the prototype detector. Images obtained by the prototype detector with a 420-nm laser light source showed good agreement with the simulation results. This indicates that the proposed detector is feasible for use in a muon tomography system and can be used to verify the Z-discrimination capability of the muon tomography system.

  2. Proton computed tomography

    International Nuclear Information System (INIS)

    Hanson, K.M.

    1978-01-01

    The use of protons or other heavy charged particles instead of x rays in computed tomography (CT) is explored. The results of an experimental implementation of proton CT are presented. High quality CT reconstructions are obtained at an average dose reduction factor compared with an EMI 5005 x-ray scanner of 10:1 for a 30-cm-diameter phantom and 3.5:1 for a 20-cm diameter. The spatial resolution is limited by multiple Coulomb scattering to about 3.7 mm FWHM. Further studies are planned in which proton and x-ray images of fresh human specimens will be compared. Design considerations indicate that a clinically useful proton CT scanner is eminently feasible

  3. X-Ray Micro-Tomography Applied to Nasa's Materials Research: Heat Shields, Parachutes and Asteroids

    Science.gov (United States)

    Panerai, Francesco; Borner, Arnaud; Ferguson, Joseph C.; Mansour, Nagi N.; Stern, Eric C.; Barnard, Harold S.; Macdowell, Alastair A.; Parkinson, Dilworth Y.

    2017-01-01

    X-ray micro-tomography is used to support the research on materials carried out at NASA Ames Research Center. The technique is applied to a variety of applications, including the ability to characterize heat shield materials for planetary entry, to study the Earth- impacting asteroids, and to improve broadcloths of spacecraft parachutes. From micro-tomography images, relevant morphological and transport properties are determined and validated against experimental data.

  4. X-ray microtome by fluorescence tomography

    CERN Document Server

    Simionovici, A S; Guenzler, F; Schrör, C; Snigirev, A; Snigireva, I; Tümmler, J; Weitkamp, T

    2001-01-01

    The X-ray fluorescence microtomography method is presented, which is capable of virtually slicing samples to obtain cross-sections of their inner structure. High precision experimental results of fluo-tomography in 'pencil-beam' geometry with up to 1.2 mu m resolution are described. Image reconstructions are based on either a simplified algebraic reconstruction method (ART) or the filtered back-projection method (FBP). Phantoms of inhomogeneous test objects as well as biological samples are successfully analyzed.

  5. Sintomas depressivos em crianças: estudos com duas versões do CDI

    Directory of Open Access Journals (Sweden)

    Miriam Cruvinel

    Full Text Available O objetivo deste estudo foi identificar o número de crianças com sintomas depressivos em duas amostras de estudantes da cidade de campinas. Utilizou-se, no estudo 1, a versão brasileira do Inventário de Depressão Infantil (CDI e, no estudo 2, a versão original. Do estudo 1, realizado em 2001, participaram 169 estudantes de 3ª, 4ª e 5ª séries, e, do estudo 2, conduzido em 2005, 157 alunos de 3ª e 4ª séries. A prevalência de sintomatologia depressiva no estudo 1 foi de 3,55%, e, no estudo 2, de 17%. Em ambos os estudos, não foram encontradas diferenças significativas entre a média no CDI em relação às variáveis demográficas. conclui-se pela necessidade de mais estudos nacionais de prevalência no ensino fundamental e de esforços direcionados não só para a identificação dos fatores de risco, de proteção e das variáveis associadas mas também do refinamento dos instrumentos de medidas da depressão infantil.

  6. Tomography

    International Nuclear Information System (INIS)

    1985-01-01

    Already widely accepted in medicine, tomography can also be useful in industry. The theory behind tomography and a demonstration of the technique to inspect a motorcycle carburetor is presented. To demonstrate the potential of computer assisted tomography (CAT) to accurately locate defects in three dimensions, a sectioned 5 cm gate valve with a shrink cavity made visible by the sectioning was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +-1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  7. Preliminary investigations on high energy electron beam tomography

    Energy Technology Data Exchange (ETDEWEB)

    Baertling, Yves; Hoppe, Dietrich; Hampel, Uwe

    2010-12-15

    In computed tomography (CT) cross-sectional images of the attenuation distribution within a slice are created by scanning radiographic projections of an object with a rotating X-ray source detector compound and subsequent reconstruction of the images from these projection data on a computer. CT can be made very fast by employing a scanned electron beam instead of a mechanically moving X-ray source. Now this principle was extended towards high-energy electron beam tomography with an electrostatic accelerator. Therefore a dedicated experimental campaign was planned and carried out at the Budker Institute of Nuclear Physics (BINP), Novosibirsk. There we investigated the capabilities of BINP's accelerators as an electron beam generating and scanning unit of a potential high-energy electron beam tomography device. The setup based on a 1 MeV ELV-6 (BINP) electron accelerator and a single detector. Besides tomographic measurements with different phantoms, further experiments were carried out concerning the focal spot size and repeat accuracy of the electron beam as well as the detector's response time and signal to noise ratio. (orig.)

  8. High-speed X-ray phase tomography with Talbot interferometer and fringe scanning method

    International Nuclear Information System (INIS)

    Kibayashi, Shunsuke; Harasse, Sébastien; Yashiro, Wataru; Momose, Atsushi

    2012-01-01

    High-speed X-ray phase tomography based on the Fourier-transform method has been demonstrated with an X-ray Talbot interferometer using white synchrotron radiation. We report the experimental results of high-speed X-ray phase tomography with fringe-scanning method instead of Fourier-transform method to improve spatial resolution without a considerable increase of scan time. To apply fringe-scanning method to high speed tomography, we tested a scan that is a synchronous combination of one-way continuous movements of the sample rotation and the grating displacement. When this scanning method was combined with X-ray phase tomography, we were able to obtain a scan time of 5 s. A comparison of the image quality derived with the conventional approach and with the proposed approach using the fringe-scanning method showed that the latter had better spatial resolution.

  9. estudo comparativo

    OpenAIRE

    Álvaro, Rocha

    2005-01-01

    O sítio web é um importante meio de comunicação e competitividade das universidades. Há diferentes razões para acreditar que os sítios possam variar entre universidades, mas contudo há certeza da existência de requisitos de qualidade comuns e transversais a todas. Este estudo visou avaliar, de forma quantitativa e objectiva, o cumprimento de requisitos de qualidade pelos sítios web das Universidades Portuguesas, com base nas características de alto nível da norma ISO 9126-1 que interessam aos...

  10. Densitometria da vértebra dorsal, osso pleural e osso neural em tartarugas verdes hígidas por tomografia computadorizada quantitativa Densitometry of dorsal vertebrae, pleural bone and neural bone in healthy green sea turtles by quantitative computed tomography

    Directory of Open Access Journals (Sweden)

    Jannine Forattini de Oliveira

    2012-08-01

    Full Text Available A tomografia computadorizada quantitativa (TCQ é uma técnica com alta sensibilidade, aplicabilidade e precisão no diagnóstico de perda de massa óssea, entretanto a falta de valores de normalidade para animais silvestres limita a sua aplicação clínica. O presente estudo objetiva estabelecer valores médios de radiodensidade do osso trabecular das vértebras dorsais, osso pleural e osso neural de tartarugas marinhas juvenis hígidas utilizando a TCQ. Para isso, utilizou-se um grupo experimental de cinco animais que foram submetidos a exames de tomografia computadorizada helicoidal, sendo as mensurações da radiodensidade óssea realizadas ao nível da terceira, quarta e quinta vértebras dorsais. Os valores médios de radiodensidade do osso trabecular das vértebras dorsais, osso pleural e osso neural foram, respectivamente, de 287,4±39,1, 1093,74±100,4 e 1089,6±86,5 unidades Hounsfield (HU. Estudos complementares devem ser realizados em diferentes espécies e faixas etárias de quelônios para favorecer a aplicação clínica desta técnica.Quantitative computed tomography (QCT is a technique with high sensitivity, applicability and accuracy in the diagnosis of bone loss; however the lack of normal values for wild animals limits their clinical application. This study aims to establish medium values radiodensity trabecular bone of the dorsal vertebrae, bone pleural and neural bone in healthy juvenile sea turtles using the QTC. For this we used an experimental group of five animals that underwent helical computed tomography, and measurements of bone radiodensity conducted at the level of the third, fourth and fifth dorsal vertebrae. The medium values of radiodensity trabecular bone of the dorsal vertebrae, pleural bone, and neural bone were respectively 287.4±39.1, 1093.74±100.4, and 1089.6±86.5 Hounsfield units (HU. Further studies should be performed in different species and ages of turtles to encourage the clinical application of

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  12. Degradation of metallic materials studied by correlative tomography

    Science.gov (United States)

    Burnett, T. L.; Holroyd, N. J. H.; Lewandowski, J. J.; Ogurreck, M.; Rau, C.; Kelley, R.; Pickering, E. J.; Daly, M.; Sherry, A. H.; Pawar, S.; Slater, T. J. A.; Withers, P. J.

    2017-07-01

    There are a huge array of characterization techniques available today and increasingly powerful computing resources allowing for the effective analysis and modelling of large datasets. However, each experimental and modelling tool only spans limited time and length scales. Correlative tomography can be thought of as the extension of correlative microscopy into three dimensions connecting different techniques, each providing different types of information, or covering different time or length scales. Here the focus is on the linking of time lapse X-ray computed tomography (CT) and serial section electron tomography using the focussed ion beam (FIB)-scanning electron microscope to study the degradation of metals. Correlative tomography can provide new levels of detail by delivering a multiscale 3D picture of key regions of interest. Specifically, the Xe+ Plasma FIB is used as an enabling tool for large-volume high-resolution serial sectioning of materials, and also as a tool for preparation of microscale test samples and samples for nanoscale X-ray CT imaging. The exemplars presented illustrate general aspects relating to correlative workflows, as well as to the time-lapse characterisation of metal microstructures during various failure mechanisms, including ductile fracture of steel and the corrosion of aluminium and magnesium alloys. Correlative tomography is already providing significant insights into materials behaviour, linking together information from different instruments across different scales. Multiscale and multifaceted work flows will become increasingly routine, providing a feed into multiscale materials models as well as illuminating other areas, particularly where hierarchical structures are of interest.

  13. Mathematics in computed tomography and related techniques

    International Nuclear Information System (INIS)

    Sawicka, B.

    1992-01-01

    The mathematical basis of computed tomography (CT) was formulated in 1917 by Radon. His theorem states that the 2-D function f(x,y) can be determined at all points from a complete set of its line integrals. Modern methods of image reconstruction include three approaches: algebraic reconstruction techniques with simultaneous iterative reconstruction or simultaneous algebraic reconstruction; convolution back projection; and the Fourier transform method. There is no one best approach. Because the experimental data do not strictly satisfy theoretical models, a number of effects have to be taken into account; in particular, the problems of beam geometry, finite beam dimensions and distribution, beam scattering, and the radiation source spectrum. Tomography with truncated data is of interest, employing mathematical approximations to compensate for the unmeasured projection data. Mathematical techniques in image processing and data analysis are also extensively used. 13 refs

  14. Optical coherence tomography angiography in age-related macular degeneration: The game changer.

    Science.gov (United States)

    Lupidi, Marco; Cerquaglia, Alessio; Chhablani, Jay; Fiore, Tito; Singh, Sumit Randhir; Cardillo Piccolino, Felice; Corbucci, Roberta; Coscas, Florence; Coscas, Gabriel; Cagini, Carlo

    2018-04-01

    Optical coherence tomography angiography is one of the biggest advances in ophthalmic imaging. It enables a depth-resolved assessment of the retinal and choroidal blood flow, far exceeding the levels of detail commonly obtained with dye angiographies. One of the first applications of optical coherence tomography angiography was in detecting the presence of choroidal neovascularization in age-related macular degeneration and establishing its position in relation to the retinal pigmented epithelium and Bruch's membrane, and thereby classifying the CNV as type 1, type 2, type 3, or mixed lesions. Optical coherence tomography angiograms, due to the longer wavelength used by optical coherence tomography, showed a more distinct choroidal neovascularization vascular pattern than fluorescein angiography, since there is less suffering from light scattering or is less obscured by overlying subretinal hemorrhages or exudation. Qualitative and quantitative assessments of optical coherence tomography angiography findings in exudative and nonexudative age-related macular degeneration have been largely investigated within the past 3 years both in clinical and experimental settings. This review constitutes an up-to-date of all the potential applications of optical coherence tomography angiography in age-related macular degeneration in order to better understand how to translate its theoretical usefulness into the current clinical practice.

  15. Comparative study of a low-Z cone-beam computed tomography system

    International Nuclear Information System (INIS)

    Roberts, D A; Hansen, V N; Poludniowski, G; Evans, P M; Thompson, M G; Niven, A; Seco, J

    2011-01-01

    Computed tomography images have been acquired using an experimental (low atomic number (Z) insert) megavoltage cone-beam imaging system. These images have been compared with standard megavoltage and kilovoltage imaging systems. The experimental system requires a simple modification to the 4 MeV electron beam from an Elekta Precise linac. Low-energy photons are produced in the standard medium-Z electron window and a low-Z carbon electron absorber located after the window. The carbon electron absorber produces photons as well as ensuring that all remaining electrons from the source are removed. A detector sensitive to diagnostic x-ray energies is also employed. Quantitative assessment of cone-beam computed tomography (CBCT) contrast shows that the low-Z imaging system is an order of magnitude or more superior to a standard 6 MV imaging system. CBCT data with the same contrast-to-noise ratio as a kilovoltage imaging system (0.15 cGy) can be obtained in doses of 11 and 244 cGy for the experimental and standard 6 MV systems, respectively. Whilst these doses are high for everyday imaging, qualitative images indicate that kilovoltage like images suitable for patient positioning can be acquired in radiation doses of 1-8 cGy with the experimental low-Z system.

  16. Specificity of the tomography implementation in electric arc domain - Validity in medical imaging

    International Nuclear Information System (INIS)

    Benech, Julie

    2008-01-01

    The aim of these works was to implement a new experimental method to characterize 3D thermal plasmas by emission spectroscopy. The method used is based on tomographic technique which is widely used in medical imaging nowadays. However, tomography that we have developed and applied to electric arc is specific as the number of accessible projections angles is strongly limited: 4 projections our case against basically 64 in medical imaging. The particularity of our experimental tomographic system is that measurements are resolved both spectrally and spatially. The spectral resolution is necessary to determine the temperature values from method based on atomic line intensity. The spatial resolution is needed to simultaneously acquire the whole width of the plasma and so to reconstruct a whole cross-section in only one acquisition. One of the principal objective was to realize the experimental system of four-view tomography for thermal plasmas. Thanks to this device, we showed that the characterization of non-axisymmetric plasma is possible and that it enables to reconstruct 3D temperature maps. Finally, our tomographic method is applied with medical imaging data acquired in SPECT (Single Photon Emission Computed Tomography). These tests allowed validating the use of our tomographic reconstruction technique in SPECT, particularly the used iterative algebraic algorithm and the limited-view configuration. (author) [fr

  17. 3D computed tomography using a microfocus X-ray source: Analysis of artifact formation in the reconstructed images using simulated as well as experimental projection data

    International Nuclear Information System (INIS)

    Krimmel, S.; Stephan, J.; Baumann, J.

    2005-01-01

    The scope of this contribution is to identify and to quantify the influence of different parameters on the formation of image artifacts in X-ray computed tomography (CT) resulting for example, from beam hardening or from partial lack of information using 3D cone beam CT. In general, the reconstructed image quality depends on a number of acquisition parameters concerning the X-ray source (e.g. X-ray spectrum), the geometrical setup (e.g. cone beam angle), the sample properties (e.g. absorption characteristics) and the detector properties. While it is difficult to distinguish the influence of different effects clearly in experimental projection data, they can be selected individually with the help of simulated projection data by varying the parameter set. The reconstruction of the 3D data set is performed with the filtered back projection algorithm according to Feldkamp, Davis and Kress for experimental as well as for simulated projection data. The experimental data are recorded with an industrial microfocus CT system which features a focal spot size of a few micrometers and uses a digital flat panel detector for data acquisition

  18. In Vivo Diffuse Optical Tomography and Fluorescence Molecular Tomography

    Directory of Open Access Journals (Sweden)

    Mingze Li

    2010-01-01

    Full Text Available Diffuse optical tomography (DOT and fluorescence molecular tomography (FMT are two attractive imaging techniques for in vivo physiological and psychological research. They have distinct advantages such as non-invasiveness, non-ionizing radiation, high sensitivity and longitudinal monitoring. This paper reviews the key components of DOT and FMT. Light propagation model, mathematical reconstruction algorithm, imaging instrumentation and medical applications are included. Future challenges and perspective on optical tomography are discussed.

  19. Modelo experimental para o estudo da hérnia do disco intervertebral Experimental model to study intervertebral disc herniation

    Directory of Open Access Journals (Sweden)

    André Luiz de Souza Grava

    2008-04-01

    Full Text Available OBJETIVO: Apresentar um modelo experimental de hérnia de disco e sua validação para estudo da hiperalgesia mecânica e térmica produzidas pelo contato do núcleo pulposo (NP com as estruturas nervosas envolvidas nessa afecção. MÉTODOS: Foram utilizados ratos Wistar, sendo o NP autólogo retirado da região sacrococcígea e depositado sobre a dura-máter, raiz nervosa ou gânglios das raízes dorsais L4, L5 ou L6. Os experimentos foram divididos em quatro etapas: 1ª determinação da estrutura nervosa mais sensível ao contato com o NP; 2ª identificação do melhor nível lombar para a indução da hiperalgesia; 3ª determinação da ausência de lesão motora; e 4ª determinação da influência do procedimento cirúrgico no desenvolvimento do processo inflamatório. A hiperalgesia foi avaliada nos testes de von Frey eletrônico e de Hargreaves e a função motora, pelo teste de rota-rod. RESULTADOS: O NP induziu hiperalgesia de maior intensidade na pata quando em contato com o gânglio da raiz dorsal (GRD do que em contato com a dura-máter ou a raiz nervosa. Quando em contato com o GRD-L5, o NP induziu hiperalgesia ainda maior que a induzida pelo contato com os GRDs L4 e L6. Não foram observadas lesão motora e influência do processo inflamatório cirúrgico sobre a hiperalgesia. CONCLUSÃO: O GRD é a estrutura mais sensível aos componentes do NP para a produção da hiperalgesia, sendo o quinto nível lombar o que apresentou maior alteração nas sensibilidades mecânica e térmica avaliadas na pata dos animais, de acordo com os métodos utilizados.OBJECTIVE:The purpose of this study is to present an experimental model of disc herniation and to validate such model to study mechanic and thermal hyperalgesia produced by the contact of the nucleus pulposus (NP with nerve structures involved in this condition. METHODS: The authors used Wistar rats, the autologous NP being removed from the sacrococcygeal region and deposited on the

  20. Simulation on a limited angle beam gamma ray tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jung, Sung Hee; Moon, Jin Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    Limited angle beam tomography was introduced in the medical field more than two decades ago, where it was mainly used for cardiovascular diagnostics. Later, it was also used to trace multiphase flows. In these studies, the detection systems were fixed and a scanning electron beam was rapidly swept across an xray target using deflection coils. Thus very fast scanning was possible in these studies, but their geometry resulted in a heavy and bulky system because of a complex control system and vacuum tube. Because of its heavy hardware, limited angle beam tomography has remained as indoor equipment. If the source section is replaced by a gamma ray source, limited angle beam tomography will have a very light source device. In addition, limited angle beam tomography with a gamma ray source can be designed using an open type portable gantry because it does not need a vacuum guide for an electron beam. There is a lot of need for a portable tomographic system but so far no definitive solution has been created. The inspection of industrial on-line pipes, wood telephone poles, and cultural assets are some application areas. This study introduces limited angle beam gamma ray tomography, its simulation, and image reconstruction results. Image reconstruction was performed on the virtual experimental data from a Monte Carlo simulation. Image reconstruction algorithms that are known to be useful for limited angle data were applied and their results compared

  1. Acousto-electrical speckle pattern in Lorentz force electrical impedance tomography

    International Nuclear Information System (INIS)

    Grasland-Mongrain, Pol; Destrempes, François; Cloutier, Guy; Mari, Jean-Martial; Souchon, Rémi; Catheline, Stefan; Chapelon, Jean-Yves; Lafon, Cyril

    2015-01-01

    Ultrasound speckle is a granular texture pattern appearing in ultrasound imaging. It can be used to distinguish tissues and identify pathologies. Lorentz force electrical impedance tomography is an ultrasound-based medical imaging technique of the tissue electrical conductivity. It is based on the application of an ultrasound wave in a medium placed in a magnetic field and on the measurement of the induced electric current due to Lorentz force. Similarly to ultrasound imaging, we hypothesized that a speckle could be observed with Lorentz force electrical impedance tomography imaging. In this study, we first assessed the theoretical similarity between the measured signals in Lorentz force electrical impedance tomography and in ultrasound imaging modalities. We then compared experimentally the signal measured in both methods using an acoustic and electrical impedance interface. Finally, a bovine muscle sample was imaged using the two methods. Similar speckle patterns were observed. This indicates the existence of an ‘acousto-electrical speckle’ in the Lorentz force electrical impedance tomography with spatial characteristics driven by the acoustic parameters but due to electrical impedance inhomogeneities instead of acoustic ones as is the case of ultrasound imaging. (paper)

  2. Acousto-electrical speckle pattern in Lorentz force electrical impedance tomography

    Science.gov (United States)

    Grasland-Mongrain, Pol; Destrempes, François; Mari, Jean-Martial; Souchon, Rémi; Catheline, Stefan; Chapelon, Jean-Yves; Lafon, Cyril; Cloutier, Guy

    2015-05-01

    Ultrasound speckle is a granular texture pattern appearing in ultrasound imaging. It can be used to distinguish tissues and identify pathologies. Lorentz force electrical impedance tomography is an ultrasound-based medical imaging technique of the tissue electrical conductivity. It is based on the application of an ultrasound wave in a medium placed in a magnetic field and on the measurement of the induced electric current due to Lorentz force. Similarly to ultrasound imaging, we hypothesized that a speckle could be observed with Lorentz force electrical impedance tomography imaging. In this study, we first assessed the theoretical similarity between the measured signals in Lorentz force electrical impedance tomography and in ultrasound imaging modalities. We then compared experimentally the signal measured in both methods using an acoustic and electrical impedance interface. Finally, a bovine muscle sample was imaged using the two methods. Similar speckle patterns were observed. This indicates the existence of an ‘acousto-electrical speckle’ in the Lorentz force electrical impedance tomography with spatial characteristics driven by the acoustic parameters but due to electrical impedance inhomogeneities instead of acoustic ones as is the case of ultrasound imaging.

  3. ACREDITAÇÃO HOSPITALAR: UM ESTUDO DE CASO

    Directory of Open Access Journals (Sweden)

    Felipe Antunes

    2005-06-01

    Full Text Available Este artigo aborda a qualidade e acreditação hospitalar através do Manual das Organizações Prestadoras de Serviços Hospitalares, desenvolvido pela Organização Nacional de Acreditação (ONA. O objetivo geral deste trabalho é avaliar o processo de acreditação, identificando dificuldades e benefícios advindos da implantação deste  Manual. Após a realização de uma revisão bibliográfica sobre qualidade em hospitais e normas da qualidade aplicáveis a hospitais, é feita uma análise crítica teórica do Manual das Organizações Prestadoras de Serviços Hospitalares. Tal análise crítica inclui um estudo comparativo entre os requisitos do Manual e da norma NBR ISO 9001/2000. A seguir, a análise teórica é complementada através de um estudo de caso contemplando a implantação do Manual junto a um hospital de grande porte. Finalmente, são apresentadas as conclusões, baseadas tanto no estudo teórico como no estudo prático.

  4. Measurement of absolute bone blood flow by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nahmias, C.; Cockshott, W.P.; Garnett, E.S.; Belbeck, L.W.

    1986-03-01

    A method of measuring bone blood flow has been developed using /sup 18/F sodium fluoride and positron emission tomography. The blood flow levels are in line with those obtained experimentally from microsphere embolisation. This investigative method could be applied to elucidate a number of clinical questions involving bone perfusion.

  5. Caracterização de um modelo experimental de Diabetes Mellitus, induzido pela aloxana em ratos: estudo clínico e laboratorial

    Directory of Open Access Journals (Sweden)

    Lerco Mauro Masson

    2003-01-01

    Full Text Available OBJETIVO: O presente estudo teve por objetivo caracterizar as alterações clínicas e laboratoriais do rato portador de Diabetes Mellitus induzido pela administração endovenosa de aloxana. MÉTODOS: Os animais foram distribuídos, por sorteio, em dois grupos experimentais: Grupo Controle Normal (G1, constituído de 25 animais sadios, e Grupo Diabético (G2, formado por 25 animais diabéticos graves, que foram avaliados em cinco momentos (1, 3, 6, 9 e 12 meses de seguimento, tendo sido estudados os seguintes parâmetros: evolução clínica (peso, ingestão hídrica, ingestão alimentar e diurese e exames bioquímicos (glicemia de jejum, glicose urinária, glicosúria, cetonúria, colesterol total, colesterol HDL, triglicérides e lipídios. RESULTADOS: A injeção de aloxana 2% na via endovenosa do rato acompanhou-se de um índice de mortalidade de 39%, tendo produzido diabetes grave também em 39% dos animais. O diabetes foi caracterizado por queda progressiva do peso corporal, elevação substancial da ingestão hídrica, ingestão alimentar e da diurese, com valores glicêmicos acima de 300 mg/dl, glicosúria 3+ e, eventualmente, cetonúria. O diabetes não altera o perfil de colesterol e lípides de ratos a longo prazo. CONCLUSÃO: Nossos estudos revelam que a aloxana produz, no rato, alterações clínicas e laboratoriais características de diabetes grave, as quais possibilitam estudos a longo prazo do diabetes.

  6. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  7. Tomography of a simply magnetized toroidal plasma

    Science.gov (United States)

    Ruggero, BARNI; Stefano, CALDIROLA; Luca, FATTORINI; Claudia, RICCARDI

    2018-02-01

    Optical emission spectroscopy is a passive diagnostic technique, which does not perturb the plasma state. In particular, in a hydrogen plasma, Balmer-alpha (H α ) emission can be easily measured in the visible range along a line of sight from outside the plasma vessel. Other emission lines in the visible spectral range from hydrogen atoms and molecules can be exploited too, in order to gather complementary pieces of information on the plasma state. Tomography allows us to capture bi-dimensional structures. We propose to adopt an emission spectroscopy tomography for studying the transverse profiles of magnetized plasmas when Abel inversion is not exploitable. An experimental campaign was carried out at the Thorello device, a simple magnetized torus. The characteristics of the profile extraction method, which we implemented for this purpose are discussed, together with a few results concerning the plasma profiles in a simply magnetized torus configuration.

  8. Considerations that may influence the result of trials assessing tensile strength in experimental surgery Considerações que podem influir no resultado de pesquisas que avaliam a resistência tênsil em cirurgia experimental

    Directory of Open Access Journals (Sweden)

    Lucas Félix Rossi

    2007-12-01

    Full Text Available PURPOSE: To provide information gathered upon the execution of trials assessing tensile strength in experimental surgeries. METHODS: Descriptive study considering details on the execution of trials assessing tensile strength in experimental surgery. RESULTS: The analysis of the rupture force in a mechanical test machine is an adequate technique since it provides precise and quick results. It can, undoubtedly, be developed in this context of the eminently mechanical analysis of trials on experimental surgery. CONCLUSION: The utilization of a mechanical test machine is a useful tool in the assessment of materials' strength, providing accurate results. Nevertheless the trials must be well structured analyzing the multiple variables so as to attain a pattern of constant reproducibility and to provide the necessary reliability.OBJETIVO: Fornecer informações advindas da experiência com a realização de trabalhos que avaliam a resistência tênsil em cirurgia experimental. MÉTODOS: Estudo descritivo considerando detalhes da execução de trabalhos que avaliam a resistência tênsil em cirurgia experimental. RESULTADOS: A análise da força de ruptura em máquina de ensaios mecânicos é uma técnica apropriada e que fornece resultados precisos e rápidos. Pode ser desenvolvida neste contexto da análise eminentemente mecânica de estudos em cirurgia experimental. CONCLUSÃO: A utilização da máquina de ensaios mecânicos é uma ferramenta útil na avaliação da resistência de materiais fornecendo resultados precisos. Entretanto os trabalhos devem ser estruturados analisando múltiplas variáveis para alcançar um padrão de reprodutibilidade constante e trazer a confiabilidade necessária ao estudo.

  9. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  10. Frequency domain fluorescence diffuse tomography of small animals

    Science.gov (United States)

    Orlova, Anna G.; Turchin, Ilya V.; Kamensky, Vladislav A.; Plehanov, Vladimir I.; Balalaeva, Irina V.; Sergeeva, Ekaterina A.; Shirmanova, Marina V.; Kleshnin, Michail S.

    2007-05-01

    Fluorescent compounds for selective cancer cell marking are used for development of novel medical diagnostic methods, investigation of the influence of external factors on tumor growth, regress and metastasis. Only special tools for turbid media imaging, such as optical diffusion tomography permit noninvasive monitoring of fluorescent-labeled tumor alterations deep in animal tissue. In this work, the results of preliminary experiments utilizing frequency-domain fluorescent diffusion tomography (FD FDT) experimental setup in small animal are presented. Low-frequency modulated light (1 kHz) from Nd:YAG laser with second harmonic generation at the wavelength of 532 nm was used in the setup. The transilluminative planar configuration was used in the setup. A series of model experiments has been conducted and show good agreement between theoretical and experimental fluorescence intensity. Models of deep tumors were created by two methods: (1) glass capsules containing fluorophore solution were inserted into esophagus of small animals to simulate marked tumors; (2) a suspension of transfected HEΚ293-Turbo-RFP cells was subcutaneously injected to small animal. The conducted experiments have shown that FD FDT allows one to detect the presence of labeled tumor cells in small animals, to determine the volume of an experimental tumor, to perform 3D tumor reconstruction, as well as to conduct monitoring investigations. The obtained results demonstrate the potential capability of the FD FDT method for noninvasive whole-body imaging in cancer studies, diagnostics and therapy.

  11. An All-Fiber-Optic Combined System of Noncontact Photoacoustic Tomography and Optical Coherence Tomography.

    Science.gov (United States)

    Eom, Jonghyun; Shin, Jun Geun; Park, Soongho; Rim, Sunghwan; Lee, Byeong Ha

    2016-05-20

    We propose an all-fiber-based dual-modal imaging system that combines noncontact photoacoustic tomography (PAT) and optical coherence tomography (OCT). The PAT remotely measures photoacoustic (PA) signals with a 1550-nm laser on the surface of a sample by utilizing a fiber interferometer as an ultrasound detector. The fiber-based OCT, employing a swept-source laser centered at 1310 nm, shares the sample arm of the PAT system. The fiber-optic probe for the combined system was homemade with a lensed single-mode fiber (SMF) and a large-core multimode fiber (MMF). The compact and robust common probe is capable of obtaining both the PA and the OCT signals at the same position without any physical contact. Additionally, the MMF of the probe delivers the short pulses of a Nd:YAG laser to efficiently excite the PA signals. We experimentally demonstrate the feasibility of the proposed dual-modal system with a phantom made of a fishing line and a black polyethylene terephthalate fiber in a tissue mimicking solution. The all-fiber-optic system, capable of providing complementary information about absorption and scattering, has a promising potential in minimally invasive and endoscopic imaging.

  12. An All-Fiber-Optic Combined System of Noncontact Photoacoustic Tomography and Optical Coherence Tomography

    Science.gov (United States)

    Eom, Jonghyun; Shin, Jun Geun; Park, Soongho; Rim, Sunghwan; Lee, Byeong Ha

    2016-01-01

    We propose an all-fiber-based dual-modal imaging system that combines noncontact photoacoustic tomography (PAT) and optical coherence tomography (OCT). The PAT remotely measures photoacoustic (PA) signals with a 1550-nm laser on the surface of a sample by utilizing a fiber interferometer as an ultrasound detector. The fiber-based OCT, employing a swept-source laser centered at 1310 nm, shares the sample arm of the PAT system. The fiber-optic probe for the combined system was homemade with a lensed single-mode fiber (SMF) and a large-core multimode fiber (MMF). The compact and robust common probe is capable of obtaining both the PA and the OCT signals at the same position without any physical contact. Additionally, the MMF of the probe delivers the short pulses of a Nd:YAG laser to efficiently excite the PA signals. We experimentally demonstrate the feasibility of the proposed dual-modal system with a phantom made of a fishing line and a black polyethylene terephthalate fiber in a tissue mimicking solution. The all-fiber-optic system, capable of providing complementary information about absorption and scattering, has a promising potential in minimally invasive and endoscopic imaging. PMID:27213392

  13. An All-Fiber-Optic Combined System of Noncontact Photoacoustic Tomography and Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Jonghyun Eom

    2016-05-01

    Full Text Available We propose an all-fiber-based dual-modal imaging system that combines noncontact photoacoustic tomography (PAT and optical coherence tomography (OCT. The PAT remotely measures photoacoustic (PA signals with a 1550-nm laser on the surface of a sample by utilizing a fiber interferometer as an ultrasound detector. The fiber-based OCT, employing a swept-source laser centered at 1310 nm, shares the sample arm of the PAT system. The fiber-optic probe for the combined system was homemade with a lensed single-mode fiber (SMF and a large-core multimode fiber (MMF. The compact and robust common probe is capable of obtaining both the PA and the OCT signals at the same position without any physical contact. Additionally, the MMF of the probe delivers the short pulses of a Nd:YAG laser to efficiently excite the PA signals. We experimentally demonstrate the feasibility of the proposed dual-modal system with a phantom made of a fishing line and a black polyethylene terephthalate fiber in a tissue mimicking solution. The all-fiber-optic system, capable of providing complementary information about absorption and scattering, has a promising potential in minimally invasive and endoscopic imaging.

  14. Marketing do mercado de luxo: Estudo de caso Victoria's Secret

    OpenAIRE

    Ana Francisca Giuliani

    2013-01-01

    Este artigo teve por objetivo identificar quais são as estratégias de marketing utilizadas pela empresa varejista Victoria’s Secret para a fidelização do consumidor de luxo em nível global. O estudo caracterizou-se como uma pesquisa qualitativa, utilizando-se como estratégia de campo o estudo de caso de caráter ilustrativo. Para o alcance do objetivo proposto, dividiu-se o estudo em duas fases. Na primeira, denominada exploratória, buscou-se em dados secundários o embasamento para a construçã...

  15. Priority choice experimental two-qubit tomography: measuring one by one all elements of density matrices

    Czech Academy of Sciences Publication Activity Database

    Bartkiewicz, K.; Černoch, Antonín; Lemr, K.; Miranowicz, A.

    2016-01-01

    Roč. 6, Jan (2016), 1-7, č. článku 19610. ISSN 2045-2322 R&D Projects: GA ČR GAP205/12/0382 Institutional support: RVO:68378271 Keywords : entangled photons * state tomography Subject RIV: BH - Optics, Masers, Lasers Impact factor: 4.259, year: 2016

  16. The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in resectable pancreatic cancer.

    Science.gov (United States)

    Crippa, Stefano; Salgarello, Matteo; Laiti, Silvia; Partelli, Stefano; Castelli, Paola; Spinelli, Antonello E; Tamburrino, Domenico; Zamboni, Giuseppe; Falconi, Massimo

    2014-08-01

    The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in pancreatic ductal adenocarcinoma is debated. We retrospectively assessed the value of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in addition to conventional imaging as a staging modality in pancreatic cancer. (18)Fluoro-deoxyglucose positron emission tomography/computed tomography was performed in 72 patients with resectable pancreatic carcinoma after multi-detector computed tomography positron emission tomography was considered positive for a maximum standardized uptake value >3. Overall, 21% of patients had a maximum standardized uptake value ≤ 3, and 60% of those had undergone neoadjuvant treatment (P=0.0001). Furthermore, 11% of patients were spared unwarranted surgery since positron emission tomography/computed tomography detected metastatic disease. All liver metastases were subsequently identified with contrast-enhanced ultrasound. Sensitivity and specificity of positron emission tomography/computed tomography for distant metastases were 78% and 100%. The median CA19.9 concentration was 48.8 U/mL for the entire cohort and 292 U/mL for metastatic patients (P=0.112). The widespread application of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in patients with resectable pancreatic carcinoma seems not justified. It should be considered in selected patients at higher risk of metastatic disease (i.e. CA19.9>200 U/mL) after undergoing other imaging tests. Neoadjuvant treatment is significantly associated with low metabolic activity, limiting the value of positron emission tomography in this setting. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  17. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  18. Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists.

    Science.gov (United States)

    Neubauer, Jakob; Benndorf, Matthias; Reidelbach, Carolin; Krauß, Tobias; Lampert, Florian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Fiebich, Martin; Goerke, Sebastian M

    2016-01-01

    To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = radiography (P radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run.

  19. A circular aperture array for ultrasonic tomography and quantitative NDE

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, S A

    1998-08-01

    The main topics of this thesis are ultrasonic tomography and ultrasonic determination of elastic stiffness constants. Both issues are based on a synthetic array with transducer elements distributed uniformly along a circular aperture, i.e., a circular aperture array. The issues are treated both theoretically and experimentally by broadband pulse techniques. Ultrasonic tomography, UCT, from a circular aperture is a relatively new imaging technique in Non-destructive Evaluation (NDE) to acquire cross sectional images in bulk materials. A filtered back-projection algorithm is used to reconstruct images in four different experiments and results of attenuation, velocity and reflection tomograms in Plexiglas of AlSi-alloy cylinders are presented. Two kinds of ultrasonic tomography are introduced: bistatic and monostatic imaging. Both techniques are verified experimentally by Plexiglas cylinders. Different reconstruction artifacts are discussed and theoretical resolution constraints are discussed for various configurations of the circular aperture array. The monostatic technique is used in volumetric imaging. In the experimental verification artificial and real discontinuities in a cylindrical AlSi-alloy are compared with similar discontinuities in a Plexiglas specimen. Finally, some limitations to UCT are discussed. The circular aperture array is used to determine five independent elastic stiffness constants of a unidirectional glass/PET (Poly Ethylene Teraphtalate) laminate. Energy flux propagation and attenuation of ultrasonic waves are considered and velocity surfaces are calculated for different planes of interest. Relations between elastic stiffness constants and engineering constants (i.e., Young`s moduli, shear moduli and Poisson`s ratios) are discussed for an orthotropic composite. Six micromechanical theories are reviewed, and expressions predicting the elastic engineering constants are evaluated. The micromechanical predicted elastic stiffness constants for the

  20. Pragmatismo e os pragmáticos nos estudos organizacionais

    Directory of Open Access Journals (Sweden)

    Francis Kanashiro Meneghetti

    Full Text Available O objetivo central deste ensaio teórico é avaliar as contribuições do pragmatismo nos Estudos Organizacionais e, os específicos, avaliar se as contribuições teóricas de Charles Peirce e John Dewey possibilitam afirmar o pragmatismo como senso comum, ciência ou teoria do conhecimento; analisar as contribuições - possibilidadese limites - do pragmatismo como conhecimento científico; compreender os percursos do pragmatismo nos Estudos Organizacionais. Chaga-se a conclusão de que ser pragmático é diferente de conceber estudos articulados no campo epistemológico do pragmatismo. O sujeito pragmático vê na sua utilidade e na necessidade deação, o ponto de tensão que coloca em dúvida a veracidade dos pressupostos do pragmatismo como ciência. O que ocorre nos Estudos Organizacionais éa conversão do pragmatismo como conhecimento científico emsubordinação irracional à utilidade e à ação prática, sobretudo, no campo da economia, da política, da ciência, da cultura, da educação, e assim por diante.

  1. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  2. Neural-network quantum state tomography

    Science.gov (United States)

    Torlai, Giacomo; Mazzola, Guglielmo; Carrasquilla, Juan; Troyer, Matthias; Melko, Roger; Carleo, Giuseppe

    2018-05-01

    The experimental realization of increasingly complex synthetic quantum systems calls for the development of general theoretical methods to validate and fully exploit quantum resources. Quantum state tomography (QST) aims to reconstruct the full quantum state from simple measurements, and therefore provides a key tool to obtain reliable analytics1-3. However, exact brute-force approaches to QST place a high demand on computational resources, making them unfeasible for anything except small systems4,5. Here we show how machine learning techniques can be used to perform QST of highly entangled states with more than a hundred qubits, to a high degree of accuracy. We demonstrate that machine learning allows one to reconstruct traditionally challenging many-body quantities—such as the entanglement entropy—from simple, experimentally accessible measurements. This approach can benefit existing and future generations of devices ranging from quantum computers to ultracold-atom quantum simulators6-8.

  3. A novel phantom design for emission tomography enabling scatter- and attenuation-''free'' single-photon emission tomography imaging

    International Nuclear Information System (INIS)

    Larsson, S.A.; Johansson, L.; Jonsson, C.; Pagani, M.; Jacobsson, H.

    2000-01-01

    A newly designed technique for experimental single-photon emission tomography (SPET) and positron emission tomography (PET) data acquisition with minor disturbing effects from scatter and attenuation has been developed. In principle, the method is based on discrete sampling of the radioactivity distribution in 3D objects by means of equidistant 2D planes. The starting point is a set of digitised 2D sections representing the radioactivity distribution of the 3D object. Having a radioactivity-related grey scale, the 2D images are printed on paper sheets using radioactive ink. The radioactive sheets can be shaped to the outline of the object and stacked into a 3D structure with air or some arbitrary dense material in between. For this work, equidistantly spaced transverse images of a uniform cylindrical phantom and of the digitised Hoffman rCBF phantom were selected and printed out on paper sheets. The uniform radioactivity sheets were imaged on the surface of a low-energy ultra-high-resolution collimator (4 mm full-width at half-maximum) of a three-headed SPET camera. The reproducibility was 0.7% and the uniformity was 1.2%. Each rCBF sheet, containing between 8.3 and 80 MBq of 99m TcO 4 - depending on size, was first imaged on the collimator and then stacked into a 3D structure with constant 12 mm air spacing between the slices. SPET was performed with the sheets perpendicular to the central axis of the camera. The total weight of the stacked rCBF phantom in air was 63 g, giving a scatter contribution comparable to that of a point source in air. The overall attenuation losses were <20%. A second SPET study was performed with 12-mm polystyrene plates in between the radioactive sheets. With polystyrene plates, the total phantom weight was 2300 g, giving a scatter and attenuation magnitude similar to that of a patient study. With the proposed technique, it is possible to obtain ''ideal'' experimental images (essentially built up by primary photons) for comparison with

  4. Review of muon tomography

    International Nuclear Information System (INIS)

    Feng Hanliang; Jiao Xiaojing

    2010-01-01

    As a new detection technology, Muon tomography has some potential benefits, such as being able to form a three- dimensional image, without radiation, low cost, fast detecting etc. Especially, muon tomography will play an important role in detecting nuclear materials. It introduces the theory of Muon tomography, its advantages and the Muon tomography system developed by decision sciences corporation and Los Alamos national laboratory. (authors)

  5. Borehole radar diffraction tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seong Jun; Kim, Jung Ho; Yi, Myeong Jong; Chung, Seung Hwan; Lee, Hee Il [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1997-12-01

    Tomography is widely used as imaging method for determining subsurface structure. Among the reconstruction algorithms for tomographic imaging, travel time tomography is almost applied to imaging subsurface. But isolated small body comparable with the wavelength could not be well recognized by travel time tomography. Other tomographic method are need to improve the imaging process. In the study of this year, diffraction tomography was investigated. The theory for diffraction tomography is based on the 1st-order Born approximation. Multisource holography, which is similar to Kirchihoff migration, is compared with diffraction tomography. To improve 1st-order Born diffraction tomography, two kinds of filter designed from multisource holography and 2-D green function, respectively, applied on the reconstructed image. The algorithm was tested for the numerical modeling data of which algorithm consists of the analytic computation of radar signal in transmitter and receiver regions and 2-D FDM scheme for the propagation of electromagnetic waves in media. The air-filled cavity model to show a typical diffraction pattern was applied to diffraction tomography imaging, and the result shows accurate location and area of cavity. But the calculated object function is not well matched the real object function, because the air-filled cavity model is not satisfied week scattered inhomogeneity for 1st born approximation, and the error term is included in estimating source wavelet from received signals. In spite of the object function error, the diffraction tomography assist for interpretation of subsurface as if conducted with travel time tomography. And the fracture model was tested, 1st born diffraction tomographic image is poor because of limited view angle coverage and violation of week scatter assumption, but the filtered image resolve the fracture somewhat better. The tested diffraction tomography image confirms effectiveness of filter for enhancing resolution. (author). 14

  6. Pulsed excitation terahertz tomography - multiparametric approach

    Science.gov (United States)

    Lopato, Przemyslaw

    2018-04-01

    This article deals with pulsed excitation terahertz computed tomography (THz CT). Opposite to x-ray CT, where just a single value (pixel) is obtained, in case of pulsed THz CT the time signal is acquired for each position. Recorded waveform can be parametrized - many features carrying various information about examined structure can be calculated. Based on this, multiparametric reconstruction algorithm was proposed: inverse Radon transform based reconstruction is applied for each parameter and then fusion of results is utilized. Performance of the proposed imaging scheme was experimentally verified using dielectric phantoms.

  7. Estudo comparativo da reação inflamatória renal entre álcool de polivinil - flocular e álcool de polivinil + acetato de polivinil - esférico: estudo experimental

    Directory of Open Access Journals (Sweden)

    Warley Dias Siqueira Mendes

    Full Text Available OBJETIVO: Avaliar as características e os efeitos de um agente embólico, disponível comercialmente, consistindo de Polivinil Álcool (PVA de morfologia flocular, e comparar com um agente esférico, de tecnologia nacional, consistindo de Polivinil Álcool e Polivinil Acetato (PVA + PVAc. MÉTODO: Foram utilizadas fêmeas de coelho albino "New Zealand", submetidas à embolização arterial renal. PVA-flocular foi usado em 24 animais, assim como PVA+PVAc-esférico. Seis animais foram utilizados como controle. Todos foram mantidos em cativeiro até a morte, por períodos pós-operatórios de 48 horas, cinco dias, 10 dias e 30 dias. RESULTADOS: Ambos os agentes promoveram oclusão do vaso e infarto do órgão. O estudo microscópico inicial das artérias embolizadas com PVA-flocular, mostra oclusão com trombo e PVA. Os vasos embolizados com PVA+PVAc-esférico, mostram os agentes ocupando praticamente todo o lúmen. No estudo de 30 dias, observa-se absorção do trombo e retração dos agentes de PVAflocular, criando espaços. E com PVA+PVAc-esférico, pode-se observar os agentes circundados por intensa fibrose. CONCLUSÕES: Ambas as partículas foram efetivas para causar isquemia tecidual. A reação inflamatória foi mais intensa com PVA+PVAc-esférico que também apresentou grau de penetração maior no sistema vascular.

  8. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  9. A Teoria Queer e os Estudos Organizacionais: Revisando Conceitos sobre Identidade

    Directory of Open Access Journals (Sweden)

    Eloisio Moulin de Souza

    2017-05-01

    Full Text Available A teoria queer desenvolveu-se incialmente na década de noventa, nas ciências sociais e humanas, principalmente nos estudos literários e linguísticos, sendo posteriormente incorporada aos estudos organizacionais. Entretanto, apesar de sua aplicação aos estudos organizacionais, ainda existe uma lacuna acerca do debate sobre seus conceitos e significados. Por isso, este artigo objetiva aprofundar e revisar o debate sobre os aspectos desenvolvidos por essa teoria, focando-se nos conceitos relacionados à produção identitária e subjetiva. Para cumprir este intento, as ideias queer sobre identidade, sujeito, performatividade, performance e identificação são apresentadas e debatidas. Defende-se que a teoria queer é um verbo (ação ao invés de um substantivo (identidade e a aplicação de seus conceitos não se restringe somente aos estudos sobre gênero, sexualidade e minorias. Por fim, discute-se a expansão da utilização dos conceitos queer no estudo de outras formas hegemônicas de categorias identitárias presentes no mundo corporativo.

  10. Laser-Assisted Atom Probe Tomography of Deformed Minerals: A Zircon Case Study.

    Science.gov (United States)

    La Fontaine, Alexandre; Piazolo, Sandra; Trimby, Patrick; Yang, Limei; Cairney, Julie M

    2017-04-01

    The application of atom probe tomography to the study of minerals is a rapidly growing area. Picosecond-pulsed, ultraviolet laser (UV-355 nm) assisted atom probe tomography has been used to analyze trace element mobility within dislocations and low-angle boundaries in plastically deformed specimens of the nonconductive mineral zircon (ZrSiO4), a key material to date the earth's geological events. Here we discuss important experimental aspects inherent in the atom probe tomography investigation of this important mineral, providing insights into the challenges in atom probe tomography characterization of minerals as a whole. We studied the influence of atom probe tomography analysis parameters on features of the mass spectra, such as the thermal tail, as well as the overall data quality. Three zircon samples with different uranium and lead content were analyzed, and particular attention was paid to ion identification in the mass spectra and detection limits of the key trace elements, lead and uranium. We also discuss the correlative use of electron backscattered diffraction in a scanning electron microscope to map the deformation in the zircon grains, and the combined use of transmission Kikuchi diffraction and focused ion beam sample preparation to assist preparation of the final atom probe tip.

  11. Partial gastrectomy associated to anterior truncal vagotomy: alterations in metabolism of the calcium. Experimental study in rats Gastrectomia parcial e vagotomia troncular anterior: alterações no metabolismo de cálcio. Estudo experimental em ratos

    Directory of Open Access Journals (Sweden)

    Elisvânia Freitas dos Santos

    2009-06-01

    ção. RESULTADOS: Os animais controle apresentaram médias estatísticas maiores (P<0.05 para o consumo de dieta, ganho de peso, cálcio sérico, cálcio urinário, excreção de cálcio nas fezes, absorção aparente de cálcio e atividade da enzima fosfatase alcalina comparados aos animais do grupo gastrectomizado. Entretanto, a concentração de cálcio ósseo foi superior no grupo de animais gastrectomizados (P<0,05 quando comparado com o grupo controle. CONCLUSÃO: A gastrectomia parcial associada à vagotomia troncular anterior mostrou ser um bom modelo experimental para estudo com o metabolismo de cálcio, ocasionando diminuição da absorção de cálcio, cálcio sérico, cálcio urinário e fosfatase alcalina. No entanto, para alterações a nível ósseo em ratos, sugere-se um estudo experimental em período maior.

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  13. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  16. Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography and (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for recurrent prostate carcinoma: results of a prospective clinical trial.

    Science.gov (United States)

    Schuster, David M; Nieh, Peter T; Jani, Ashesh B; Amzat, Rianot; Bowman, F Dubois; Halkar, Raghuveer K; Master, Viraj A; Nye, Jonathon A; Odewole, Oluwaseun A; Osunkoya, Adeboye O; Savir-Baruch, Bital; Alaei-Taleghani, Pooneh; Goodman, Mark M

    2014-05-01

    We prospectively evaluated the amino acid analogue positron emission tomography radiotracer anti-3-[(18)F]FACBC compared to ProstaScint® ((111)In-capromab pendetide) single photon emission computerized tomography-computerized tomography to detect recurrent prostate carcinoma. A total of 93 patients met study inclusion criteria who underwent anti-3-[(18)F]FACBC positron emission tomography-computerized tomography plus (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for suspected recurrent prostate carcinoma within 90 days. Reference standards were applied by a multidisciplinary board. We calculated diagnostic performance for detecting disease. In the 91 of 93 patients with sufficient data for a consensus on the presence or absence of prostate/bed disease anti-3-[(18)F]FACBC had 90.2% sensitivity, 40.0% specificity, 73.6% accuracy, 75.3% positive predictive value and 66.7% negative predictive value compared to (111)In-capromab pendetide with 67.2%, 56.7%, 63.7%, 75.9% and 45.9%, respectively. In the 70 of 93 patients with a consensus on the presence or absence of extraprostatic disease anti-3-[(18)F]FACBC had 55.0% sensitivity, 96.7% specificity, 72.9% accuracy, 95.7% positive predictive value and 61.7% negative predictive value compared to (111)In-capromab pendetide with 10.0%, 86.7%, 42.9%, 50.0% and 41.9%, respectively. Of 77 index lesions used to prove positivity histological proof was obtained in 74 (96.1%). Anti-3-[(18)F]FACBC identified 14 more positive prostate bed recurrences (55 vs 41) and 18 more patients with extraprostatic involvement (22 vs 4). Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography correctly up-staged 18 of 70 cases (25.7%) in which there was a consensus on the presence or absence of extraprostatic involvement. Better diagnostic performance was noted for anti-3-[(18)F]FACBC positron emission tomography-computerized tomography than for (111)In-capromab pendetide single

  17. Estudos de atmosfera

    OpenAIRE

    Carlos Eduardo Riccioppo

    2016-01-01

    Joker e Estudos de balística possuíam formas distintas dos cadernos ou livros quando foram exibidos pela primeira vez, na mostra Dual Overdrive. De algum modo, o flagrante das imagens dos cartazes da campanha política parisiense e daquelas cusparadas sobre o asfalto era preservado no modo como eram mostrados os trabalhos, que repunham não apenas a orientação espacial dos objetos fotografados, mas, igualmente, sua escala: Joker apresentava-se na parede, em dimensões relativamente próximas às d...

  18. Personalidade e comportamentos problema: um estudo comparativo com adolescentes em contexto escolar

    Directory of Open Access Journals (Sweden)

    Renato G. Carvalho

    2014-03-01

    Full Text Available Neste estudo transversal analisámos a relação entre os comportamentos problema ao nível da indisciplina, desrespeito e conflituosidade dos adolescentes, em contexto escolar, e a personalidade e a psicopatologia, operacionalizadas nas dimensões PSY-5 do MMPI-A. Participaram no estudo 351 estudantes do 9º ao 12º ano, com idades compreendidas entre os 14 e os 18 anos, distribuídos em três grupos diferentes, de acordo com o reporte da frequência de comportamentos problema. Os instrumentos foram a versão experimental portuguesa do MMPI-A e um questionário sobre diferentes dimensões do percurso escolar, em que se incluem os comportamentos problema. Através de análise estatística multivariada, verificámos diferenças significativas entre os grupos nas dimensões PSY-5, num padrão em que o grupo de maior frequência de comportamentos problema apresenta resultados superiores no MMPI-A. Os resultados são interpretados numa perspetiva que sublinha a relevância da personalidade na adaptação à vida escolar, bem como a importância da existência de técnicas de avaliação psicológica de forma a detetar, em contexto de normalidade, estudantes em risco de desenvolvimento de trajetórias inadaptativas.

  19. Studies on muon tomography for archaeological internal structures scanning

    Science.gov (United States)

    Gómez, H.; Carloganu, C.; Gibert, D.; Jacquemier, J.; Karyotakis, Y.; Marteau, J.; Niess, V.; Katsanevas, S.; Tonazzo, A.

    2016-05-01

    Muon tomography is a potential non-invasive technique for internal structure scanning. It has already interesting applications in geophysics and can be used for archaeological purposes. Muon tomography is based on the measurement of the muon flux after crossing the structure studied. Differences on the mean density of these structures imply differences on the detected muon rate for a given direction. Based on this principle, Monte Carlo simulations represent a useful tool to provide a model of the expected muon rate and angular distribution depending on the composition of the studied object, being useful to estimate the expected detected muons and to better understand the experimental results. These simulations are mainly dependent on the geometry and composition of the studied object and on the modelling of the initial muon flux at surface. In this work, the potential of muon tomography in archaeology is presented and evaluated with Monte Carlo simulations by estimating the differences on the muon rate due to the presence of internal structures and its composition. The influence of the chosen muon model at surface in terms of energy and angular distributions in the final result has been also studied.

  20. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  1. Quantitative tomography simulations and reconstruction algorithms

    International Nuclear Information System (INIS)

    Martz, H.E.; Aufderheide, M.B.; Goodman, D.; Schach von Wittenau, A.; Logan, C.; Hall, J.; Jackson, J.; Slone, D.

    2000-01-01

    X-ray, neutron and proton transmission radiography and computed tomography (CT) are important diagnostic tools that are at the heart of LLNL's effort to meet the goals of the DOE's Advanced Radiography Campaign. This campaign seeks to improve radiographic simulation and analysis so that radiography can be a useful quantitative diagnostic tool for stockpile stewardship. Current radiographic accuracy does not allow satisfactory separation of experimental effects from the true features of an object's tomographically reconstructed image. This can lead to difficult and sometimes incorrect interpretation of the results. By improving our ability to simulate the whole radiographic and CT system, it will be possible to examine the contribution of system components to various experimental effects, with the goal of removing or reducing them. In this project, we are merging this simulation capability with a maximum-likelihood (constrained-conjugate-gradient-CCG) reconstruction technique yielding a physics-based, forward-model image-reconstruction code. In addition, we seek to improve the accuracy of computed tomography from transmission radiographs by studying what physics is needed in the forward model. During FY 2000, an improved version of the LLNL ray-tracing code called HADES has been coupled with a recently developed LLNL CT algorithm known as CCG. The problem of image reconstruction is expressed as a large matrix equation relating a model for the object being reconstructed to its projections (radiographs). Using a constrained-conjugate-gradient search algorithm, a maximum likelihood solution is sought. This search continues until the difference between the input measured radiographs or projections and the simulated or calculated projections is satisfactorily small

  2. One step linear reconstruction method for continuous wave diffuse optical tomography

    Science.gov (United States)

    Ukhrowiyah, N.; Yasin, M.

    2017-09-01

    The method one step linear reconstruction method for continuous wave diffuse optical tomography is proposed and demonstrated for polyvinyl chloride based material and breast phantom. Approximation which used in this method is selecting regulation coefficient and evaluating the difference between two states that corresponding to the data acquired without and with a change in optical properties. This method is used to recovery of optical parameters from measured boundary data of light propagation in the object. The research is demonstrated by simulation and experimental data. Numerical object is used to produce simulation data. Chloride based material and breast phantom sample is used to produce experimental data. Comparisons of results between experiment and simulation data are conducted to validate the proposed method. The results of the reconstruction image which is produced by the one step linear reconstruction method show that the image reconstruction almost same as the original object. This approach provides a means of imaging that is sensitive to changes in optical properties, which may be particularly useful for functional imaging used continuous wave diffuse optical tomography of early diagnosis of breast cancer.

  3. The tomography inside of a Fourier Optics course: some opto-mechanical illustrative arrays

    International Nuclear Information System (INIS)

    Rodriguez Z, G.; Rodriguez V, R.; Luna C, A.

    1999-01-01

    The introduction of tomography as an advanced topic to be included in a Fourier optics course at graduated level is proposed. It is shown a possible presentation sequence which features the use of typical Fourier optics techniques, as well as some well known opto-mechanical devices as examples. Finally, a simplified apparatus which illustrates the central Fourier theorem as an experimental project on Fourier optics is described. Corresponding experimental results are also shown. (Author)

  4. Simulation of Underground Muon Flux with Application to Muon Tomography

    Science.gov (United States)

    Yamaoka, J. A. K.; Bonneville, A.; Flygare, J.; Lintereur, A.; Kouzes, R.

    2015-12-01

    Muon tomography uses highly energetic muons, produced by cosmic rays interacting within the upper atmosphere, to image dense materials. Like x-rays, an image can be constructed from the negative of the absorbed (or scattered) muons. Unlike x-rays, these muons can penetrate thousands of meters of earth. Muon tomography has been shown to be useful across a wide range of applications (such as imaging of the interior of volcanoes and cargo containers). This work estimates the sensitivity of muon tomography for various underground applications. We use simulations to estimate the change in flux as well as the spatial resolution when imaging static objects, such as mine shafts, and dynamic objects, such as a CO2 reservoir filling over time. We present a framework where we import ground density data from other sources, such as wells, gravity and seismic data, to generate an expected muon flux distribution at specified underground locations. This information can further be fed into a detector simulation to estimate a final experimental sensitivity. There are many applications of this method. We explore its use to image underground nuclear test sites, both the deformation from the explosion as well as the supporting infrastructure (access tunnels and shafts). We also made estimates for imaging a CO2 sequestration site similar to Futuregen 2.0 in Illinois and for imaging magma chambers beneath the Cascade Range volcanoes. This work may also be useful to basic science, such as underground dark matter experiments, where increasing experimental sensitivity requires, amongst other factors, a precise knowledge of the muon background.

  5. Terahertz imaging and tomography as efficient instruments for testing polymer additive manufacturing objects.

    Science.gov (United States)

    Perraud, J B; Obaton, A F; Bou-Sleiman, J; Recur, B; Balacey, H; Darracq, F; Guillet, J P; Mounaix, P

    2016-05-01

    Additive manufacturing (AM) technology is not only used to make 3D objects but also for rapid prototyping. In industry and laboratories, quality controls for these objects are necessary though difficult to implement compared to classical methods of fabrication because the layer-by-layer printing allows for very complex object manufacturing that is unachievable with standard tools. Furthermore, AM can induce unknown or unexpected defects. Consequently, we demonstrate terahertz (THz) imaging as an innovative method for 2D inspection of polymer materials. Moreover, THz tomography may be considered as an alternative to x-ray tomography and cheaper 3D imaging for routine control. This paper proposes an experimental study of 3D polymer objects obtained by additive manufacturing techniques. This approach allows us to characterize defects and to control dimensions by volumetric measurements on 3D data reconstructed by tomography.

  6. Cicatrização da membrana timpânica na timpanocentese com laser de argônio comparado à técnica com microlanceta: estudo experimental em ratos Tympanic membrane healing in myringotomies performed with argon laser or microknife: an experimental study in rats

    Directory of Open Access Journals (Sweden)

    Lucio Almeida Castagno

    2006-12-01

    Full Text Available Otite média secretora (OMS e otite média aguda recorrente (OMAR podem necessitar tratamento cirúrgico para adequada ventilação da orelha média. A abertura clássica do tímpano (timpanocentese requer incisão por microlanceta sob controle de microscópio cirúrgico e mantém-se patente por alguns dias. Estudos recentes sugerem que a timpanocentese feita por diferentes lasers pode permanecer permeável por maior tempo, o que possibilitaria a normalização da otite média. MATERIAL E MÉTODOS: Neste estudo experimental 34 ratos linhagem Wistar, albinos, machos adultos pesando cerca de 300g, foram anestesiados com cetamina 27 mg/kg e xilazina 2,7 mg/kg. A seguir, foram submetidos à timpanocentese incisional com microlanceta no ouvido direito (ML-OD, e à timpanocentese mediada por laser de argônio no ouvido esquerdo (LA-OE. RESULTADOS: Não houve diferença significativa no tempo de cicatrização das timpanocenteses feitas com laser de argônio ou microlanceta. Todas as timpanocenteses cicatrizaram em 10 dias. CONCLUSÃO: A timpanocentese com laser de argônio apresentou patência e cicatrização semelhantes à técnica clássica com microlanceta realizada em ratos Wistar sem enfermidades de orelha média.Secretory otitis media (SOM and recurrent acute otitis media (RAOM may require surgical treatment to proper ventilate the middle ear. Incisional myringotomy is usually done under microscopy with a micro-knife , but it remains patent for just a few days. Recent research indicates that laser assisted myringotomies remain open much longer, allowing middle ear ventilation and healing. MATERIAL AND METHODS: In this experimental study 34 white, male, adult, Wistar rats, without middle ear disease were submited to anesthesia with ketamine 27 mg/kg and xylazine 2,7 mg/kg. Incisional myringotomy was done on the right ear, while laser myringotomy was done on the left. Myringotomies were evaluated periodically until healing. RESULTS: The healing

  7. 18F-fluorodeoxyglucose positron emission tomography predicts survival of patients with neuroendocrine tumors

    DEFF Research Database (Denmark)

    Binderup, Tina; Knigge, Ulrich; Loft, Annika

    2010-01-01

    PURPOSE: (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) is currently not used on a routine basis for imaging of neuroendocrine (NE) tumors. The aim of this study was to investigate the prognostic value of FDG-PET in patients with NE tumors. EXPERIMENTAL DESIGN: Ninety...

  8. Single photon emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-09-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) imaging technique. Content: 1 - Introduction: anatomic, functional and molecular imaging; Principle and role of functional or molecular imaging; 2 - Radiotracers: chemical and physical constraints, main emitters, radioisotopes production, emitters type and imaging techniques; 3 - Single photon emission computed tomography: gamma cameras and their components, gamma camera specifications, planar single photon imaging characteristics, gamma camera and tomography; 4 - Quantification in single photon emission tomography: attenuation, scattering, un-stationary spatial resolution, partial volume effect, movements, others; 5 - Synthesis and conclusion

  9. Estudo multicasos sobre atividades inovativas

    Directory of Open Access Journals (Sweden)

    Sonia Regina Hierro Parolin

    2013-09-01

    Full Text Available Em estudos sobre competitividade argumenta-se que as empresas necessitam de estratégias baseadas em inovações e de capacidades internas em constantes e intensas transformações, não somente nos padrões tecnológicos, mas também no encadeamento do processo de gestão das atividades inovativas, como processos dinâmicos, não lineares e diversificados, em função de múltiplos fatores dos ambientes interno e externo. Para contribuir com essas discussões, neste artigo apresenta-se um estudo multicasos em quatro indústrias de médio e grande portes, de segmentos, densidades tecnológicas e históricos com inovações diferentes entre si. Como principais resultados, salientam-se o encadeamento das atividades inovativas como parte de uma estratégia organizacional para obter resultados com inovação e a afluência de todas as pessoas, e não somente as alocadas em pesquisa e desenvolvimento, para o cumprimento dessa estratégia.

  10. Cerebral blood flow measured by positron emission tomography during normothermic cardiopulmonary bypass: An experimental porcine study

    DEFF Research Database (Denmark)

    Thomassen, Sisse Anette; Kjaergaard, Benedict; Alstrup, Aage Kristian Olsen

    2018-01-01

    emission tomography (PET) using 15O-labelled water with no pharmacological interventions to maintain the MAP. Methods: Eight pigs (69-71 kg) were connected to normothermic CPB. After 60 minutes (min) with a CPB pump flow of 60 mL/kg/min, the pigs were changed to either 35 mL/kg/min or 47.5 mL/kg/min for 60......Background: Mean arterial blood pressure (MAP) and/or pump flow during normothermic cardiopulmonary bypass (CPB) are the most important factors of cerebral perfusion. The aim of this study was to explore the influence of CPB blood flow on cerebral blood flow (CBF) measured by dynamic positron...... min and, thereafter, all the pigs returned to 60 mL/kg/min for another 60 min. The MAP was measured continuously and the CBF was measured by positron emission tomography (PET) during spontaneous circulation and at each CPB pump flow after 30 min of steady state. Results: Two pigs were excluded due...

  11. Experimental approach for the uncertainty assessment of 3D complex geometry dimensional measurements using computed tomography at the mm and sub-mm scales

    DEFF Research Database (Denmark)

    Jiménez, Roberto; Torralba, Marta; Yagüe-Fabra, José A.

    2017-01-01

    The dimensional verification of miniaturized components with 3D complex geometries is particularly challenging. Computed Tomography (CT) can represent a suitable alternative solution to micro metrology tools based on optical and tactile techniques. However, the establishment of CT systems......’ traceability when measuring 3D complex geometries is still an open issue. In this work, an alternative method for the measurement uncertainty assessment of 3D complex geometries by using CT is presented. The method is based on the micro-CT system Maximum Permissible Error (MPE) estimation, determined...... experimentally by using several calibrated reference artefacts. The main advantage of the presented method is that a previous calibration of the component by a more accurate Coordinate Measuring System (CMS) is not needed. In fact, such CMS would still hold all the typical limitations of optical and tactile...

  12. Mapping residual stress by ultrasonic tomography

    International Nuclear Information System (INIS)

    Hildebrand, B.P.; Harrington, T.P.

    1979-01-01

    It is known that internal stress concentrations can give rise to microcracks which then grow when the structure is subjected to external forces. It has also been found that the velocity of sound is altered as it propagates through a region of stress. In this paper a technique called Computer-Assisted Tomography (CAT) is discussed and an application that provides pictures of stress fields is described. The results of both simulated and experimental models used to evaluate the technique are reported. It is concluded that the CAT approach has great potential for locating and mapping residual stress in metals. (author)

  13. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  14. Desenvolvimento de um conector de cisalhamento em chapa dentada para estruturas mistas de aço e concreto e estudo do seu comportamento

    OpenAIRE

    Gustavo de Souza Verissimo

    2007-01-01

    Este trabalho consiste do desenvolvimento de um conector de cisalhamento em chapa dentada para estruturas mistas de aço e concreto, incluindo o estudo do seu comportamento. O trabalho envolve uma ampla investigação para definição da geometria do conector, um programa experimental, o desenvolvimento de uma equação de resistência e o treinamento de redes neurais para a predição da resposta do conector. O programa experimental, envolvendo 41 ensaios tipo push-out, conforme a EN 1994-1-1:2004, fo...

  15. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography

    International Nuclear Information System (INIS)

    Kettler, Nele

    2011-01-01

    Imaging methods for early, accurate diagnosis and aftercare of malignant growths is currently one of the most important research topics. The objective of this thesis is to evaluate the diagnostic value of FDG-positron emission tomography by comparison with computed tomography for patients with squamous cell carcinoma, malignant melanoma or sarcoma at head and neck. Measurement criteria are sensitivity and specificity. A retrospective evaluation of 100 examinations on 85 patients of University clinic Aachen was performed. The examination reports were supported by reports from histology, positron emission tomography and computed tomography. In each case, the histological results were assumed to provide a reliable benchmark. Sensitivity and specificity for the primary tumour site, metastatic lymphatic nodes and defined anatomic structures were compared across all patients. Comparisons were also performed on sub groups separated by gender, cancer type and the time and frequency at which tumours arose. The statistic analysis was done with MedCalc. Results: The results for sensitivity and specificity of the primary tumour site were 86.42% and 42.86%, and 64.71% and 66.07%, for positron emission tomography and computed tomography respectively. The results for the lymphatic nodes were 51.52% and 92.86% and 64.71% and 66.07%. When the constituent anatomic structures were evaluated separately, the specificity was significantly higher. The separation by gender showed no difference. Because the classification by tumor type resulted in samples that were of varying size, a comparison was difficult. For the diagnosis of primary tumours, the examination with positron emission tomography was superior, whereas computed tomography proved more effective for the diagnosis of recurrent tumours. For the diagnosis of the main tumour site, both methods were shown to be equally suitable. For the assessment of lymphatic nodes, positron emission tomography was superior to computed tomography

  16. Meaning of Interior Tomography

    Science.gov (United States)

    Wang, Ge; Yu, Hengyong

    2013-01-01

    The classic imaging geometry for computed tomography is for collection of un-truncated projections and reconstruction of a global image, with the Fourier transform as the theoretical foundation that is intrinsically non-local. Recently, interior tomography research has led to theoretically exact relationships between localities in the projection and image spaces and practically promising reconstruction algorithms. Initially, interior tomography was developed for x-ray computed tomography. Then, it has been elevated as a general imaging principle. Finally, a novel framework known as “omni-tomography” is being developed for grand fusion of multiple imaging modalities, allowing tomographic synchrony of diversified features. PMID:23912256

  17. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  18. X-ray micro-tomography system for small-animal imaging with zoom-in imaging capability

    International Nuclear Information System (INIS)

    Chun, In Kon; Cho, Myung Hye; Lee, Sang Chul; Cho, Min Hyoung; Lee, Soo Yeol

    2004-01-01

    Since a micro-tomography system capable of μm-resolution imaging cannot be used for whole-body imaging of a small laboratory animal without sacrificing its spatial resolution, it is desirable for a micro-tomography system to have local imaging capability. In this paper, we introduce an x-ray micro-tomography system capable of high-resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest (ROI), we have obtained zoomed-in images of the ROI without any contrast anomalies commonly appearing in conventional local tomography. For experimental verification of the zoom-in imaging capability, we have integrated a micro-tomography system using a micro-focus x-ray source, a 1248 x 1248 flat-panel x-ray detector, and a precision scan mechanism. The mismatches between the two projection data caused by misalignments of the scan mechanism have been estimated with a calibration phantom, and the mismatch effects have been compensated in the image reconstruction procedure. Zoom-in imaging results of bony tissues with a spatial resolution of 10 lp mm -1 suggest that zoom-in micro-tomography can be greatly used for high-resolution imaging of a local region in small-animal studies

  19. Crosshole investigations - short and medium range seismic tomography

    International Nuclear Information System (INIS)

    Cosma, C.

    1987-02-01

    Seismic tomographic tests were conducted as a part of the Crosshole Investigations program of the Stripa Project. The aim has been to study if it is possible to detect by seismic tomography major fracture zones and determine their dimensions and orientation. The analysis was based on both compressional (P) and transversal (S) waves. The Young's modulus has been also calculated for a sub-set of measurements as a cross check for the P and S wave velocities. The experimental data was collected at the crosshole site in the Stripa mine during 1984-1985. A down-the-hole impact source was used together with triaxial detectors and a digital seismograph. Five tomographic sections were obtained. The number of records per section was appr. 250. Measurements were done down to 200 m depth in all boreholes. The main conclusion is that it is possible to detect major fracture zones by seismic tomography. Their position and orientation can also be estimated. (orig./HP)

  20. Positron emission tomography

    International Nuclear Information System (INIS)

    Wienhard, K.; Heiss, W.D.

    1984-01-01

    The principles and selected clinical applications of positron emission tomography are described. In this technique a chemical compound is labeled with a positron emitting isotope and its biochemical pathway is traced by coincidence detection of the two annihilation photons. The application of the techniques of computed tomography allows to reconstruct the spatial distribution of the radioactivity within a subject. The 18 F-deoxyglucose method for quantitative measurement of local glucose metabolism is discussed in order to illustrate the possibilities of positron emission tomography to record physiological processes in vivo. (orig.) [de

  1. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  2. Investigation of water films on fuel rods in boiling water reactors using neutron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lanthen, Jonas

    2006-09-15

    In a boiling water reactor, thin films of liquid water around the fuel rods play a very important role in cooling the fuel, and evaporation of the film can lead to fuel damage. If the thickness of the water film could be measured accurately the reactor operation could be both safer and more economical. In this thesis, the possibility to use neutron tomography, to study thin water films on fuel rods in an experimental nuclear fuel set-up, has been investigated. The main tool for this has been a computer simulation software. The simulations have shown that very thin water films, down to around 20 pm, can be seen on fuel rods in an experimental set-up using neutron tomography. The spatial resolution needed to obtain this result is around 300 pm. A suitable detector system for this kind of experiment would be plastic fiber scintillators combined with a CCD camera. As a neutron source it would be possible to use a D-D neutron generator, which generates neutrons with energies of 2.5 MeV. Using a neutron generator with a high enough neutron yield and a detector with high enough detection efficiency, a neutron tomography to measure thin water films should take no longer than 25 - 30 minutes.

  3. Investigation of water films on fuel rods in boiling water reactors using neutron tomography

    International Nuclear Information System (INIS)

    Lanthen, Jonas

    2006-09-01

    In a boiling water reactor, thin films of liquid water around the fuel rods play a very important role in cooling the fuel, and evaporation of the film can lead to fuel damage. If the thickness of the water film could be measured accurately the reactor operation could be both safer and more economical. In this thesis, the possibility to use neutron tomography, to study thin water films on fuel rods in an experimental nuclear fuel set-up, has been investigated. The main tool for this has been a computer simulation software. The simulations have shown that very thin water films, down to around 20 pm, can be seen on fuel rods in an experimental set-up using neutron tomography. The spatial resolution needed to obtain this result is around 300 pm. A suitable detector system for this kind of experiment would be plastic fiber scintillators combined with a CCD camera. As a neutron source it would be possible to use a D-D neutron generator, which generates neutrons with energies of 2.5 MeV. Using a neutron generator with a high enough neutron yield and a detector with high enough detection efficiency, a neutron tomography to measure thin water films should take no longer than 25 - 30 minutes

  4. Estudos organizacionais, (descolonialidade e estudos da dependência: as contribuições da Cepal

    Directory of Open Access Journals (Sweden)

    Sergio Wanderley

    Full Text Available O objetivo deste artigo é (revisitar o conceito de dependência como categoria de investigação da (e a partir da América Latina, por meio de uma perspectiva histórica crítica descolonial, a fim de ampliar o espaço de debates em estudos organizacionais e promover alternativas à ordem neoliberal. Este ensaio terá como foco os estudos da dependência realizados pela Comissão Econômica para a América Latina e o Caribe (Cepal durante a década de 1950 e o início dos anos 1960. A perspectiva descolonial é um constructo teórico de autores latino-americanos que se consideram herdeiros da longa tradição do pensamento social crítico da região, na qual a teoria da dependência está inserida. As propostas dos autores da dependência confrontaram as principais teorias ortodoxas do Norte produzidas à época. A partir do conceito de centro-periferia, da denúncia de assimetrias nas relações entre essas regiões, do reconhecimento da interdependência entre desenvolvimento e subdesenvolvimento, o conceito de dependência foi sendo (reelaborado nas décadas de 1950 e 1960 por diversos autores latino-americanos como uma categoria de investigação da realidade da (e a partir da região. Essas investigações tinham por objetivo não somente elaborar constructos teóricos, mas, também, transformar a realidade por meio da criação de diversas organizações e instituições que deveriam servir ao propósito de superar o subdesenvolvimento. A denúncia da historicidade da situação de subdesenvolvimento desnudou o caráter de neutralidade do economicismo das teorias produzidas no Norte e promoveu um encontro teórico entre economia e política que muito tem a contribuir com a área dos estudos organizacionais.

  5. Estudo experimental da aplicação das forças de compressão ou distração sobre o sistema de fixação pedicular Compression or distraction forces applied on a pedicular fixation system: an experimental study

    Directory of Open Access Journals (Sweden)

    Helton Luiz Aparecido Defino

    2006-01-01

    Full Text Available Foi realizado estudo experimental com o objetivo de avaliar os efeitos da aplicação da força de compressão e distração (aproximação e afastamento sobre os implantes colocados nos pedículos vertebrais. Foram utilizados no estudo os segmentos vertebrais T8-T9, T10-T11, T12-L1, L2-L3 e L4-L5 de suínos da raça Landsark. Cada segmento vertebral foi fixado com implantes pediculares, tendo sido aplicada força de compressão ou distração com deslocamento que variou de 5,1 mm a 9,35 mm. O deslocamento provocado pela aplicação das forças foi mensurado em quatro pontos do segmento vertebral: A (porção anterior do corpo vertebral, B (porção média do corpo vertebral, C (porção posterior do corpo vertebral e D (processo articular siperior. A força de compressão produziu o afastamento dos pontos localizados nas regiões A e B, e aproximação dos pontos da região D. A força de distração produziu a aproximação dos pontos da região A e B e o afastamento dos pontos da região D.An experimental study was conducted with the objective of evaluating the effects of compression and distraction (approach and deviation forces applied on implants placed at vertebral pedicles. The vertebral segments T8-T9, T10-T11, T12-L1, L2-L3 and L4-L5 of Landsark pigs were used in the study. Each vertebral segment was fixed with pedicular implants, with compression or distraction forces being applied with a displacement that ranged from 5.1 mm to 9.35 mm. Displacement caused by forces application was measured in four points of the vertebral segment: A (anterior portion of the vertebral segment, B (medial portion of the vertebral segment, C (posterior portion of the vertebral segment and D (superior joint process. Compression forces caused the deviation of points located at regions A and B, and the approach of points at region D. Distraction forces caused the approach of points at regions A and B and deviation of the points at region D.

  6. Single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.

    1986-01-01

    Single photon tomography dates from the early 1960's when the idea of emission transverse section tomography was presented by Kuhl and Edwards. They used a rectilinear scanner and analogue back-projection methods to detect emissions from a series of sequential positions transverse to the cephaldcaudad axis of the body. This chapter presents an explanation of emission tomography by describing longitudinal and transverse section tomography. In principle all modes of tomography can be considered under the general topic of coded apertures wherein the code ranges from translation of a pinhole collimator to rotation of a parallel hole or focused collimator array

  7. Microimaging and tomography with chemical speciation

    Energy Technology Data Exchange (ETDEWEB)

    Rau, C. E-mail: rau@esrf.fr; Somogyi, A.; Simionovici, A

    2003-01-01

    Materials science deals with the study of the morphology of samples, their chemical composition and the relation between both. One general problem is the preservation of the sample throughout the different analyses, like it is often the case for classical chemical analysis. Destruction-free chemical speciation in three dimensions with micrometer resolution can be achieved by combining X-ray spectroscopy and imaging techniques. Highly brilliant radiation is needed for this purpose available at 3rd generation synchrotrons such as the ESRF. X-ray absorption near-edge spectroscopy (XANES) is a non-destructive well-known and established technique in chemistry. By scanning the X-ray energy in the vicinity (50-100 eV) of the absorption edge of an element, information can be obtained about the oxidation state of the probed atoms. The (conventional) technique mainly employed until now applies to homogeneous, specifically prepared flat samples where the measured signal can be considered as the average over the whole irradiated volume. This restriction for samples is partially released when the XANES method is combined with imaging techniques. 2D resolved data is acquired using area detectors or by scanning with a focussed beam. X-ray absorption tomography is a method of choice for investigating the 3D structure of objects and its dual energy version is used for getting information about the 3D distribution of a given element within the sample. Although the combination of XANES and tomography seems to be a natural extension of dual-energy tomography, in practice several experimental problems have to be overcome in order to obtain useable data. In the following we describe the results of XANES imaging and tomography obtained measuring a phantom sample of pure molybdenum compounds using a FreLoN 2000 camera system at the ESRF undulator beamline ID22. This system allowed making volume resolved distinctions between different oxidation states with spatial resolution in the

  8. Quantitative imaging of magnetic nanoparticles by magneto-relaxometric tomography for biomedical applications

    International Nuclear Information System (INIS)

    Liebl, Maik

    2016-01-01

    Current biomedical research focuses on the development of novel biomedical applications based on magnetic nanoparticles (MNPs), e.g. for local cancer treatment. These therapy approaches employ MNPs as remotely controlled drug carriers or local heat generators. Since location and quantity of MNPs determine drug enrichment and heat production, quantitative knowledge of the MNP distribution inside a body is essential for the development and success of these therapies. Magnetorelaxometry (MRX) is capable to provide such quantitative information based on the specific response of the MNPs after switching-off an applied magnetic field. Applying a uniform (homogeneous) magnetic field to a MNP distribution and measuring the MNP response by multiple sensors at different locations allows for spatially resolved MNP quantification. However, to reconstruct the MNP distribution from this spatially resolved MRX data, an ill posed inverse problem has to be solved. So far, the solution of this problem was stabilized incorporating a-priori knowledge in the forward model, e.g. by setting priors on the vertical position of the distribution using a 2D reconstruction grid or setting priors on the number and geometry of the MNP sources inside the body. MRX tomography represents a novel approach for quantitative 3D imaging of MNPs, where the inverse solution is stabilized by a series of MRX measurements. In MRX tomography, only parts of the MNP distribution are sequentially magnetized by the use of inhomogeneous magnetic fields. Each magnetizing is followed by detection of the response of the corresponding part of the distribution by multiple sensors. The 3D reconstruction of the MNP distribution is then accomplished by a common evaluation of the distinct MRX measurement series. In this thesis the first experimental setup for MRX tomography was developed for quantitative 3D imaging of biomedical MNP distributions. It is based on a multi-channel magnetizing unit which has been engineered to

  9. Quantum tomography via compressed sensing: error bounds, sample complexity and efficient estimators

    International Nuclear Information System (INIS)

    Flammia, Steven T; Gross, David; Liu, Yi-Kai; Eisert, Jens

    2012-01-01

    Intuitively, if a density operator has small rank, then it should be easier to estimate from experimental data, since in this case only a few eigenvectors need to be learned. We prove two complementary results that confirm this intuition. Firstly, we show that a low-rank density matrix can be estimated using fewer copies of the state, i.e. the sample complexity of tomography decreases with the rank. Secondly, we show that unknown low-rank states can be reconstructed from an incomplete set of measurements, using techniques from compressed sensing and matrix completion. These techniques use simple Pauli measurements, and their output can be certified without making any assumptions about the unknown state. In this paper, we present a new theoretical analysis of compressed tomography, based on the restricted isometry property for low-rank matrices. Using these tools, we obtain near-optimal error bounds for the realistic situation where the data contain noise due to finite statistics, and the density matrix is full-rank with decaying eigenvalues. We also obtain upper bounds on the sample complexity of compressed tomography, and almost-matching lower bounds on the sample complexity of any procedure using adaptive sequences of Pauli measurements. Using numerical simulations, we compare the performance of two compressed sensing estimators—the matrix Dantzig selector and the matrix Lasso—with standard maximum-likelihood estimation (MLE). We find that, given comparable experimental resources, the compressed sensing estimators consistently produce higher fidelity state reconstructions than MLE. In addition, the use of an incomplete set of measurements leads to faster classical processing with no loss of accuracy. Finally, we show how to certify the accuracy of a low-rank estimate using direct fidelity estimation, and describe a method for compressed quantum process tomography that works for processes with small Kraus rank and requires only Pauli eigenstate preparations

  10. Quantitative study of luminescence optical tomography. Application to sources localisation in molecular imaging

    International Nuclear Information System (INIS)

    Boffety, Matthieu

    2010-01-01

    Molecular imaging is a major modality in the field of preclinical research. Among the existing methods, techniques based on optical detection of visible or near infrared radiation are the most recent and are mainly represented by luminescence optical tomography techniques. These methods allow for 3D characterization of a biological medium by reconstructing maps of concentration or localisation of luminescent beacons sensitive to biological and chemical processes at the molecular or cellular scale. Luminescence optical tomography is based on a model of light propagation in tissues, a protocol for acquiring surface signal and a numerical inversion procedure used to reconstruct the parameters of interest. This thesis is structured around these three axes and provides an answer to each problem. The main objective of this study is to introduce and present the tools to evaluate the theoretical performances of optical tomography methods. One of its major outcomes is the realisation of experimental tomographic reconstructions from images acquired by an optical imager designed for 2D planar imaging and developed by the company Quidd. In a first step we develop the theory of transport in scattering medium to establish the concept on which our work will rely. We present two different propagation models as well as resolution methods and theoretical difficulties associated with them. In a second part we introduce the statistical tools used to characterise tomographic systems. We define and apply a procedure to simple situations in luminescence optical tomography. The last part of this work presents the development of an inversion procedure. After introducing the theoretical framework we validate the procedure from numerical data before successfully applying it to experimental measurements. (author) [fr

  11. VOIP : um estudo experimental

    OpenAIRE

    Claudio Luis Sitolino

    2001-01-01

    Voz sobre IP (VoIP) é uma tecnologia que permite a digitalização e a codificação da voz e o empacotamento em pacotes de dados IP para a transmissão em uma rede que utilize o protocolo TCP/IP. Devido ao volume de dados gerados por uma aplicação VoIP, esta tecnologia se encontra em funcionamento, em redes corporativas privadas. Mas se a rede base para o transporte desta aplicação for a Internet, certamente, não deve ser utilizada para fins profissionais, pois o TCP/IP não oferece padrões de QoS...

  12. Estudo sobre reciclagem de lâmpadas fluorescentes

    OpenAIRE

    Bacila,Danniele Miranda; Fischer,Klaus; Kolicheski,Mônica Beatriz

    2014-01-01

    Lâmpadas fluorescentes (LF) contêm mercúrio em sua composição, um metal pesado que pode causar danos à saúde e ao meio ambiente. As LF são amplamente consumidas no Brasil, porém o descarte correto de LF usadas não é amplamente divulgado e os índices de reciclagem são baixos. O objetivo deste estudo foi demonstrar a relevância do descarte adequado, avaliar as tecnologias de reciclagem e a destinação dos materiais, por meio de estudo comparativo entre Brasil e Alemanha. Através de visitas a rec...

  13. Tomography

    International Nuclear Information System (INIS)

    Barrett, H.H.; Gordon, S.; Swindell, W.

    1980-01-01

    Apparatus is described for generating a two-dimensional back-projected image of a slice of an object in tomography. The apparatus uses optical techniques to perform the functions of filtering and back projection. Central to the technique is a cylindrical drum which rotates at a fast rate and whose rotational axis tilts at a slower rate. The novel method overcomes the problem of image blurring due to motion which occurs in many tomographic techniques. It also has the advantages of being less expensive and simpler compared to tomography using digital processing techniques which require fast computers. (UK)

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  15. Squamous cell carcinoma of the external auditory canal: computed tomography findings in six cases; Carcinoma espinocelular do conduto auditivo externo: estudo por tomografia computadorizada de seis casos

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, Fabio Mota; Paes Junior, Ademar Jose de Oliveira; Tornin, Olger de Souza [Complexo Hospitalar Heliopolis, Sao Paulo, SP (Brazil). Servico de Diagnostico por Imagem]. E-mail: fmg961@yahoo.com.br; Souza, Ricardo Pires de [Complexo Hospitalar Heliopolis, Sao Paulo, SP (Brazil). Programa de Residencia Medica em Radiologia e Diagnostico por Imagem

    2005-05-15

    Objective: to evaluate the role of computed tomography in the assessment of deep extension of squamous cell carcinoma of the external auditory canal. Materials and methods: in the period between May 1995 and December 2003 six patients with squamous cell carcinoma of the external auditory canal were submitted to computed tomography scan at 'Hospital Heliopolis', Sao Paulo, SP, Brazil, including axial and coronal slices with soft tissue and bone algorithms. Results: thickening of the soft tissue of the external auditory canal was seen in all patients, bone erosion and invasion of the middle ear in five (83.3%), invasion of the mastoid and parotid gland in four (66.7%), invasion of the temporomandibular joint in three (50%), and invasion of the middle cranial fossa, carotid canal and cervical lymph node enlargement in two (33.3%) patients. Conclusion: assessment of deep extension of squamous cell carcinoma of the external auditory canal using computed tomography is useful for clinical staging of the disease allowing better therapeutic planning for these patients. (author)

  16. Os estudos brasileiros e os 'brazilianists'

    Directory of Open Access Journals (Sweden)

    José Honório Rodrigues

    1976-09-01

    Full Text Available (primeiro parágrafo do artigo Quando, em 1943-1944, estive nos Estados Unidos, estudando e pesquisando, conheci muitas bibliotecas públicas e universitárias, e o grande Arquivo Nacional dos Estados Unidos. Nas Universidades já se ofereciam cursos de estudos latino-americanos, centralizados sobretudo no estudo da língua espanhola, portuguesa em menor escala, estenografía em espanhol, e raras propunham o ensino da literatura comparativa, antropologia, economia, geografia, política e história latino-americana, sempre em conjunto; raríssimas, como a Columbia, ofereciam aulas de história social e econômica do Brasil, e tambem do México e da América Central, e ainda da Argentina, Uruguai e Paraguai. Havia pouca especialização por paises e áreas, e se via predominantemente a América Latina como um bloco uno e uniforme.

  17. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  18. Regorafenib effects on human colon carcinoma xenografts monitored by dynamic contrast-enhanced computed tomography with immunohistochemical validation.

    Directory of Open Access Journals (Sweden)

    Clemens C Cyran

    Full Text Available To investigate dynamic contrast-enhanced computed tomography for monitoring the effects of regorafenib on experimental colon carcinomas in rats by quantitative assessments of tumor microcirculation parameters with immunohistochemical validation.Colon carcinoma xenografts (HT-29 implanted subcutaneously in female athymic rats (n = 15 were imaged at baseline and after a one-week treatment with regorafenib by dynamic contrast-enhanced computed tomography (128-slice dual-source computed tomography. The therapy group (n = 7 received regorafenib daily (10 mg/kg bodyweight. Quantitative parameters of tumor microcirculation (plasma flow, mL/100 mL/min, endothelial permeability (PS, mL/100 mL/min, and tumor vascularity (plasma volume, % were calculated using a 2-compartment uptake model. Dynamic contrast-enhanced computed tomography parameters were validated with immunohistochemical assessments of tumor microvascular density (CD-31, tumor cell apoptosis (TUNEL, and proliferation (Ki-67.Regorafenib suppressed tumor vascularity (15.7±5.3 to 5.5±3.5%; p<0.05 and tumor perfusion (12.8±2.3 to 8.8±2.9 mL/100 mL/min; p = 0.063. Significantly lower microvascular density was observed in the therapy group (CD-31; 48±10 vs. 113±25, p<0.05. In regorafenib-treated tumors, significantly more apoptotic cells (TUNEL; 11844±2927 vs. 5097±3463, p<0.05 were observed. Dynamic contrast-enhanced computed tomography tumor perfusion and tumor vascularity correlated significantly (p<0.05 with microvascular density (CD-31; r = 0.84 and 0.66 and inversely with apoptosis (TUNEL; r = -0.66 and -0.71.Regorafenib significantly suppressed tumor vascularity (plasma volume quantified by dynamic contrast-enhanced computed tomography in experimental colon carcinomas in rats with good-to-moderate correlations to an immunohistochemical gold standard. Tumor response biomarkers assessed by dynamic contrast-enhanced computed tomography may be a promising future

  19. Iterative methods for tomography problems: implementation to a cross-well tomography problem

    Science.gov (United States)

    Karadeniz, M. F.; Weber, G. W.

    2018-01-01

    The velocity distribution between two boreholes is reconstructed by cross-well tomography, which is commonly used in geology. In this paper, iterative methods, Kaczmarz’s algorithm, algebraic reconstruction technique (ART), and simultaneous iterative reconstruction technique (SIRT), are implemented to a specific cross-well tomography problem. Convergence to the solution of these methods and their CPU time for the cross-well tomography problem are compared. Furthermore, these three methods for this problem are compared for different tolerance values.

  20. Fluorodeoxyglucose-positron emission tomography/computed tomography imaging features of colloid adenocarcinoma of the lung: a case report.

    Science.gov (United States)

    Wang, ZhenGuang; Yu, MingMing; Chen, YueHua; Kong, Yan

    2017-07-27

    Colloid adenocarcinoma of the lung is a rare subtype of variants of invasive adenocarcinomas. We report the appearance of this unusual entity on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography. A 60-year-old man of Chinese Han nationality coughed with a little white sputum for 1 month. Chest computed tomography showed multiple bilateral subpleural nodules and plaques accompanied by air bronchograms, which were most concentrated in the lower lobe of his right lung. Positron emission tomography indicated increased radioactivity uptake with a maximum standardized uptake value of 3.5. Positron emission tomography/computed tomography showed a soft tissue density lesion in his left adrenal gland with a maximum standardized uptake value of 4.1. The positron emission tomography/computed tomography appearance suggested a primary colloid adenocarcinoma in the lower lobe of his right lung accompanied by intrapulmonary and left adrenal gland metastases. The diagnostic rate of colloid adenocarcinoma can be increased by combining the anatomic and metabolic information of lesions. The advantage of positron emission tomography/computed tomography in the diagnosis of colloid adenocarcinoma, as with other cancers, is the ability to locate extrapulmonary disease, facilitating clinical staging.

  1. Prospects of linear reconstruction in atomic resolution electron holographic tomography

    International Nuclear Information System (INIS)

    Krehl, Jonas; Lubk, Axel

    2015-01-01

    Tomography commonly requires a linear relation between the measured signal and the underlying specimen property; for Electron Holographic Tomography this is given by the Phase Grating Approximation (PGA). While largely valid at medium resolution, discrepancies arise at high resolution imaging conditions. We set out to investigate the artefacts that are produced if the reconstruction still assumes the PGA even with an atomic resolution tilt series. To forego experimental difficulties the holographic tilt series was simulated. The reconstructed electric potential clearly shows peaks at the positions of the atoms. These peaks have characterisitic deformations, which can be traced back to the defocus a particular atom has in the holograms of the tilt series. Exchanging an atom for one of a different atomic number results in a significant change in the reconstructed potential that is well contained within the atom's peak. - Highlights: • We simulate a holographic tilt series of a nanocrystal with atomic resolution. • Using PGA-based Holographic Tomography we reconstruct the atomic structure. • The reconstruction shows characteristic artefacts, chiefly caused by defocus. • Changing one atom's Z produces a well localised in the reconstruction

  2. Prospects of linear reconstruction in atomic resolution electron holographic tomography

    Energy Technology Data Exchange (ETDEWEB)

    Krehl, Jonas, E-mail: Jonas.Krehl@triebenberg.de; Lubk, Axel

    2015-03-15

    Tomography commonly requires a linear relation between the measured signal and the underlying specimen property; for Electron Holographic Tomography this is given by the Phase Grating Approximation (PGA). While largely valid at medium resolution, discrepancies arise at high resolution imaging conditions. We set out to investigate the artefacts that are produced if the reconstruction still assumes the PGA even with an atomic resolution tilt series. To forego experimental difficulties the holographic tilt series was simulated. The reconstructed electric potential clearly shows peaks at the positions of the atoms. These peaks have characterisitic deformations, which can be traced back to the defocus a particular atom has in the holograms of the tilt series. Exchanging an atom for one of a different atomic number results in a significant change in the reconstructed potential that is well contained within the atom's peak. - Highlights: • We simulate a holographic tilt series of a nanocrystal with atomic resolution. • Using PGA-based Holographic Tomography we reconstruct the atomic structure. • The reconstruction shows characteristic artefacts, chiefly caused by defocus. • Changing one atom's Z produces a well localised in the reconstruction.

  3. O apelo ecológico na propaganda como fator de influência na atitude de compra do consumidor: um estudo experimental

    OpenAIRE

    Santos, João Maurício

    2010-01-01

    Este estudo examinou o apelo ecológico utilizado na propaganda como influenciador na atitude de compra do consumidor, tendo em vista que nas duas últimas décadas houve um crescimento nos anúncios que utilizam este tipo de apelo, demonstrando que, pelo surgimento de um novo nicho de mercado, empresas têm se valido do marketing verde e da influência normativa na sua estratégia de marketing. Buscou-se investigar se efetivamente o uso do apelo ecológico na propaganda influencia pos...

  4. Estudo experimental da aplicação retiniana do laser infravermelho via transescleral sob condições de baixa visibilidade Transscleral infrared laser retinal photocoagulation experimental study under low visibility conditions

    Directory of Open Access Journals (Sweden)

    Dario Grechi Goulart

    2008-06-01

    Full Text Available OBJETIVOS: Pesquisa experimental, com laser de diodo infravermelho, para estimar a segurança, a reprodutibilidade e a permeabilidade da parede ocular à sua atuação clínica, quando aplicado via transescleral, em condições de baixa visibilidade. MÉTODOS: Submetemos olhos de coelhos pigmentados da raça Nova Zelândia à fotocoagulação retiniana por laser de diodo infravermelho. No olho direito, realizamos fotocoagulação via transescleral sob parâmetros de potência e tempo pré-determinados clinicamente. No olho esquerdo, foram repetidos os mesmos valores da potência e tempo usados no olho direito, desta vez, via transpupilar. Imediatamente e após 2 meses, estudos clínicos baseados na retinografia e histopatológicos foram realizados. RESULTADOS: A permeabilidade da parede ocular, quando da aplicação do laser de diodo infravermelho via transescleral, variou entre 58,95 e 63,87%. A média da permeabilidade da parede ocular a 300 mW (63,14% mostrou-se significativamente superior àquela da permeabilidade da parede ocular encontrada a 500 mW (59,11%, (PPURPOSE: Retinal photocoagulation under poor visualization condition is often required. Transscleral infrared laser can be used as an alternative to regular transpupillary treatment. Based upon retinographic measurements, we proposed to estimate the reproducibility as well as ocular wall permeability rate for this treatment. Our primary goal was to evaluate whether this technique can deliver adequate photocoagulation at predetermined parameters without direct retinal visualization. METHODS: In New Zealand pigmented rabbits, optimal transscleral infrared diode laser settings were administered to the right eye. With the same parameters, transpupillary photocoagulation was repeated in the left eye. Retinographic and clinical examinations were performed immediately and two months later. RESULTS: Ocular wall permeability rate varied between 58.95 and 63.87%. Average permeability using a

  5. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  6. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  7. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  8. Incidental head and neck findings on 18F-fluoro-deoxy-glucose positron emission tomography computed tomography.

    Science.gov (United States)

    Williams, S P; Kinshuck, A J; Williams, C; Dwivedi, R; Wieshmann, H; Jones, T M

    2015-09-01

    The overlapping risk factors for lung and head and neck cancer present a definite risk of synchronous malignant pathology. This is the first study to specifically review incidental positron emission tomography computed tomography findings in the head and neck region in lung carcinoma patients. A retrospective review was performed of all lung cancer patients who underwent positron emission tomography computed tomography imaging over a five-year period (January 2008 - December 2012), identified from the Liverpool thoracic multidisciplinary team database. Six hundred and nine patients underwent positron emission tomography computed tomography imaging over this period. In 76 (12.5 per cent) scans, incidental regions of avid 18F-fluoro-deoxy-glucose uptake were reported in the head and neck region. In the 28 patients who were fully investigated, there were 4 incidental findings of malignancy. In lung cancer patients undergoing investigative positron emission tomography computed tomography scanning, a significant number will also present with areas of clinically significant 18F-fluoro-deoxy-glucose uptake in the head and neck region. Of these, at least 5 per cent may have an undiagnosed malignancy.

  9. An introduction to emission computed tomography

    International Nuclear Information System (INIS)

    Williams, E.D.

    1985-01-01

    This report includes salient features of the theory and an examination of practical considerations for someone who is using or introducing tomography, selecting equipment for it or wishing to develop a clinical application. Emphasis is on gamma camera tomography. The subject is dealt with under the following headings: emission computed and gamma camera tomography and the relationship to other medical imaging techniques, the tomographic reconstruction technique theory, rotating gamma camera tomography, attenuation correction and quantitative reconstruction, other single photon tomographic techniques, positron tomography, image display, clinical application of single photon and positron tomography, and commercial systems for SPECT. Substantial bibliography. (U.K.)

  10. The mystery of missing species in atom probe tomography of composite materials

    Energy Technology Data Exchange (ETDEWEB)

    Karahka, M.; Xia, Y.; Kreuzer, H. J. [Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia B3H 3J5 (Canada)

    2015-08-10

    There is a serious problem in atom probe tomography of composite materials such as oxides that even from stoichiometric samples one observes non-stoichiometric ion yields. We present a quantitative model that explains the non-stoichiometry allowing a fit to experimental data of ion yields as a function of applied field to extract activation barriers and prefactors. The numbers are confirmed by density functional theory. We also show that for oxides the missing oxygen is thermally desorbed as neutral O{sub 2}, either directly or associatively. Finally, we suggest methods to improve the experimental setup.

  11. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  12. Cardiac positron emission tomography

    International Nuclear Information System (INIS)

    Eftekhari, M.; Ejmalian, G.

    2003-01-01

    Positron emission tomography is an intrinsically tool that provide a unique and unparalleled approach for clinicians and researchers to interrogate the heart noninvasively. The ability to label substances of physiological interest with positron-emitting radioisotopes has permitted insight into normal blood flow and metabolism and the alterations that occur with disease states. Positron emission tomography of the heart has evolved as a unique, noninvasive approach for the assessment of myocardial perfusion, metabolism, and function. Because of the intrinsic quantitative nature of positron emission tomography measurements as well as the diverse compounds that can be labeled with positron- emitting radioisotopes, studies with positron emission tomography have provided rich insight into the physiology of the heart under diverse conditions

  13. ESTUDOS NACIONAIS SOBRE O ENSINO PARA CEGOS: UMA REVISÃO BIBLIOGRÁFICA

    Directory of Open Access Journals (Sweden)

    Rosana Mendes Éleres de FIGUEIREDO

    2015-12-01

    Full Text Available RESUMO O presente artigo tem como objetivo apresentar uma revisão bibliográfica dos estudos nacionais acerca do ensino curricular para cegos. Foi realizada uma busca sistemática em três bases de dados: Google Acadêmico, Scielo e Lilacs, de estudos publicados no período de 2004 a 2014, que tivessem em seu título um dos seguintes descritores: alunos cegos; alunos deficientes visuais; crianças cegas; crianças deficientes visuais. Foram localizados 188 estudos e 56 selecionados dentro dos critérios estabelecidos. Fez-se a leitura integral desses e definiram-se cinco categorias de análise: tipo de estudo; participantes; tipo de abordagem; tipo de discussão e matrizes curriculares. Para cada categoria, foram estabelecidas subcategorias. Ao total 26 subcategorias foram descritas. Os resultados indicam que o Google Acadêmico é a base de dados com maior número de títulos encontrados (188/156; a Scielo apresenta melhor eficiência na relação encontrado x selecionado (12/10. Nas subcategorias de análise, as maiores frequências são identificadas nos estudos empíricos (22; junto a crianças (19; de análises qualitativas (21; na matriz curricular de Educação Física (sete e na subcategoria relacionamento social (16. Contudo, os estudos são convergentes em apontar que as principais dificuldades no ensino às pessoas cegas se referem a deficiências na formação de professores, onde, normalmente, não são discutidos métodos de ensino e produção de material para trabalhar com essa população específica. Em conclusão, além de realizar um mapeamento dos estudos que têm sido conduzidos junto a alunos cegos nos últimos dez anos, este artigo aponta para lacunas na literatura e direciona futuras investigações na área.

  14. [Contribution of X-ray computed tomography in the evaluation of kidney performance].

    Science.gov (United States)

    Lemoine, Sandrine; Rognant, Nicolas; Collet-Benzaquen, Diane; Juillard, Laurent

    2012-07-01

    X-ray computer assisted tomography scanner is an imaging method based on the use of X-ray attenuation in tissue. This attenuation is proportional to the density of the tissue (without or after contrast media injection) in each pixel image of the image. Spiral scanner, the electron beam computed tomography (EBCT) scanner and multidetector computed tomography scanner allow renal anatomical measurements, such as cortical and medullary volume, but also the measurement of renal functional parameters, such as regional renal perfusion, renal blood flow and glomerular filtration rate. These functional parameters are extracted from the modeling of the kinetics of the contrast media concentration in the vascular space and the renal tissue, using two main mathematical models (the gamma variate model and the Patlak model). Renal functional imaging allows measuring quantitative parameters on each kidney separately, in a non-invasive manner, providing significant opportunities in nephrology, both for experimental and clinical studies. However, this method uses contrast media that may alter renal function, thus limiting its use in patients with chronic renal failure. Moreover, the increase irradiation delivered to the patient with multi detector computed tomography (MDCT) should be considered. Copyright © 2011 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.

  15. A new recontruction algorithm for use with capacitance-based tomography

    Directory of Open Access Journals (Sweden)

    Ø. Isaksen

    1994-01-01

    Full Text Available A new reconstruction algorithm for use with capacitance-based process tomography is proposed. A numerical simulator, capable of calculating the capacitances for a particular sensor configuration and flow regime is used together with a parameter representation of the dielectric distribution and an optimization algorithm. The algorithm calculates these parameters and hence the dielectric distribution, by minimizing a function defined as a weighted sum of square differences between the measured and estimated capacitances. The method is tested by using both synthetic and experimental data, and the results are compared with results from the commonly used Linear Back Projection (LBP algorithm. The method is capable of obtaining the correct parameter values for all the flow regimes tested, and does provide a better estimate than the LBP method. The method proves to be very promising, and is a step towards quantitative capacitance tomography.

  16. Positron emission tomography with Positome, 2

    International Nuclear Information System (INIS)

    Nukui, Hideaki; Yamamoto, Y.L.; Thompson, C.J.; Feindel, W.

    1979-01-01

    Positron emission tomography with Positome II using 68 Ga-EDTA was performed in cases with brain tumor and cerebral arteriovenous malformation. A significant focal uptake in static study and hemodynamic changes in dynamic study were noted in all cases except one case with intracranial lipoma. Comparing this method with sup(99m) Tc-pertechnetate cerebral image study and computerized axial tomography, the diagnostic rate for detecting brain tumor was almost equal in all of these three methods. However, detecting and localizing was easier and clearer in static positron emission tomography with 68 Ga-EDTA than in sup(99m) Tc-pertechnetate cerebral image and computerized axial tomography without infusion of contrast medium. Furthermore, static positron emission tomography with 68 Ga-EDTA was superior to computerized axial tomography without infusion of contrast medium for detecting cerebral arteriovenous malformation. Concerning dynamic positron emission tomography with 68 Ga-EDTA, semiquantitative values obtained by this method correlated well with findings of computerized axial tomography and was thought to be more precise and in detail than the findings of sup(99m) Tc-pertechnetate cerebral image study. Summation of the previous studies about dynamic positron emission tomography with 77 Kr in occlusive cerebrovascular disease is also reported. In conclusion, static positron emission tomography with 68 Ga-EDTA is a very useful diagnostic method for detecting and localizing brain tumor and cerebral arteriovenous malformation without any attendant complications. Furthermore, a good combination of static and dynamic positron emission tomography and computerized axial tomography appear to be outstandingly effective for not only detecting the lesion but also understanding the pathophysiological aspect in cases with various intracranial lesions. (author)

  17. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  18. Atom probe tomography simulations and density functional theory calculations of bonding energies in Cu3Au

    KAUST Repository

    Boll, Torben; Zhu, Zhiyong; Al-Kassab, Talaat; Schwingenschlö gl, Udo

    2012-01-01

    In this article the Cu-Au binding energy in Cu3Au is determined by comparing experimental atom probe tomography (APT) results to simulations. The resulting bonding energy is supported by density functional theory calculations. The APT simulations

  19. Review of possible applications of cosmic muon tomography

    International Nuclear Information System (INIS)

    Checchia, P.

    2016-01-01

    Muon radiographic methods can be used to explore inaccessible volumes profiting of the property of muons to penetrate thick materials. An extension of the muon radiographic methods, the muon scattering tomography, was proposed for the first time in 2003 and it is based on the measurement of the multiple Coulomb scattering of muons crossing the volume under investigation. In this talk, the principles of tomographic image reconstruction are first outlined and then the experimental setup and the most adequate detectors are described. A review of the possible applications of this technique is reported, with specific reference to security in transports and monitoring of industrial processes. The technique can also be used to provide precise measurements of the properties of various materials. The experimental challenge related to this activity is discussed.

  20. Review of possible applications of cosmic muon tomography

    Science.gov (United States)

    Checchia, P.

    2016-12-01

    Muon radiographic methods can be used to explore inaccessible volumes profiting of the property of muons to penetrate thick materials. An extension of the muon radiographic methods, the muon scattering tomography, was proposed for the first time in 2003 and it is based on the measurement of the multiple Coulomb scattering of muons crossing the volume under investigation. In this talk, the principles of tomographic image reconstruction are first outlined and then the experimental setup and the most adequate detectors are described. A review of the possible applications of this technique is reported, with specific reference to security in transports and monitoring of industrial processes. The technique can also be used to provide precise measurements of the properties of various materials. The experimental challenge related to this activity is discussed.

  1. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and

  2. Caso de estudo: a entrada do azeite Gallo no mercado chinês

    OpenAIRE

    Costa, Miguel Maria Portugal Martins

    2014-01-01

    Mestrado em Gestão 7 Classificação JEL: M16; F23 A elaboração desta dissertação consiste na criação de um caso de estudo pedagógico com o objectivo de tirar ilações sobre a entrada da marca “Azeite Gallo” no mercado Chinês. Optamos por desenvolver este caso de estudo através de um estudo qualitativo, suportado por um referencial teórico. O intuito do projecto é de documentar um exemplo paradigmático de um produto consumível de marca portuguesa que sucedeu em ultrapassar as barreiras ...

  3. IMPACTOS MICROCLIMÁTICOS DO DESENHO URBANO: ESTUDOS REALIZADOS EM CURITIBA

    Directory of Open Access Journals (Sweden)

    Eduardo KRUGER

    2011-04-01

    Full Text Available O artigo busca compreender as relações entre atributos da geometria urbana e alterações no microclima. São apresentados dois estudos distintos conduzidos na mesma área central de Curitiba, PR, a partir de medições de campo realizadas em 2009 e de simulações de clima urbano no software ENVI-met. Os estudos, embora utilizem a mesma campanha de coleta de dados, possuem objetivos e metodologias diferentes. O primeiro estudo foca no impacto da geometria urbana, na temperatura ambiente e nos níveis de conforto em ruas de pedestre no período diurno, sendo o fator de visão do céu utilizado como indicador da complexa geometria urbana. O segundo estudo trata do impacto da orientação das vias em relação ao vento dominante, quanto às taxas de ventilação resultantes (velocidade do ar e distribuição espacial, visando à dispersão de poluentes gerados pelo tráfego, no contexto urbano. Os resultados auferidos evidenciam a influência da forma urbana para a determinação do conforto térmico em ruas de pedestres, restringindo-se a um período diurno específico, e para a criação de cenários de poluição.

  4. Gamma tomography apparatus

    International Nuclear Information System (INIS)

    Span, F.J.

    1988-01-01

    The patent concerns a gamma tomography apparatus for medical diagnosis. The apparatus comprises a gamma scintillation camera head and a suspension system for supporting and positioning the camera head with respect for the patient. Both total body scanning and single photon emission tomography can be carried out with the apparatus. (U.K.)

  5. Computerised Axial Tomography (CAT)

    Science.gov (United States)

    1990-06-01

    Ministry of’ Defence, Defence Research Information Centre, UK. Computerised Axial Tomography ( CAT ) Report Secufty C"uMiauion tide Onadtiicadon (U. R, Cor S...DRIC T 8485 COMPUTERISED AXIAL TOMOGRAPHY ( CAT ) F.P. GENTILE, F. SABETTA, V. TRO1* ISS R 78/4.Rome, 1.5 Mlarch 1978 (from Italian) B Distribution(f...dello Radiazioni ISSN 0390--6477 F.P. GENTILE, F. SABETTA. V. TROI Computerised Axial Tomography ( CAT ) March 15, 1978). This paper is a review of

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  7. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  8. Sparse image representation for jet neutron and gamma tomography

    Energy Technology Data Exchange (ETDEWEB)

    Craciunescu, T. [EURATOM-MEdC Association, Institute for Laser, Plasma and Radiation Physics, Bucharest (Romania); Kiptily, V. [EURATOM/CCFE Association, Culham Science Centre, Abingdon (United Kingdom); Murari, A. [Consorzio RFX, Associazione EURATOM-ENEA per la Fusione, Padova (Italy); Tiseanu, I.; Zoita, V. [EURATOM-MEdC Association, Institute for Laser, Plasma and Radiation Physics, Bucharest (Romania)

    2013-10-15

    Highlights: •A new tomographic method for the reconstruction of the 2-D neutron and gamma emissivity on JET. •The method is based on the sparse representation of the reconstructed image in an over-complete dictionary. •Several techniques, based on a priori information are used to regularize this highly limited data set tomographic problem. •The proposed method provides good reconstructions in terms of shapes and resolution. -- Abstract: The JET gamma/neutron profile monitor plasma coverage of the emissive region enables tomographic reconstruction. However, due to the availability of only two projection angles and to the coarse sampling, tomography is a highly limited data set problem. A new reconstruction method, based on the sparse representation of the reconstructed image in an over-complete dictionary, has been developed and applied to JET neutron/gamma tomography. The method has been tested on JET experimental data and significant results are presented. The proposed method provides good reconstructions in terms of shapes and resolution.

  9. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Disseminated Cryptococcosis.

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography-computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm.

  10. um estudo de caso

    OpenAIRE

    Costa, Cátia Filipa Pereira da

    2011-01-01

    Dissertação apresentada à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Psicologia Jurídica As situações de abuso sexual de crianças nas quais o perpetrador pertence ao sexo feminino obtiveram ao longo dos últimos anos um acrescido reconhecimento por parte da comunidade científica, evidenciado pelo significativo incremento das investigações no âmbito desta temática consistindo na sua maioria estudos de caso. Um conjunto de particularidades encont...

  11. Aprendizagem Organizacional, Teoria Ator-Rede e Estudos Foucaultianos: Tempo, Espaço e Poder

    OpenAIRE

    Bruno Luiz Américo

    2016-01-01

    Esse trabalho baseia-se no mapeamento de lacunas encontradas nos desenvolvimentos dos estudos organizacionais de conhecimento e aprendizagem, e busca contribuir para a consolidação da aprendizagem organizacional como uma teoria do movimento organizacional/social. Para isso, propõe diálogo entre a Perspectiva Social-Política da Aprendizagem social, a Teoria Ator-Rede e os estudos foucaultianos. O trabalho conclui destacando o potencial da teoria ator-rede e dos estudos foucaultianos para anali...

  12. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  13. Corneal thickness and elevation measurements using swept-source optical coherence tomography and slit scanning topography in normal and keratoconic eyes.

    Science.gov (United States)

    Jhanji, Vishal; Yang, Bingzhi; Yu, Marco; Ye, Cong; Leung, Christopher K S

    2013-11-01

    To compare corneal thickness and corneal elevation using swept source optical coherence tomography and slit scanning topography. Prospective study. 41 normal and 46 keratoconus subjects. All eyes were imaged using swept source optical coherence tomography and slit scanning tomography during the same visit. Mean corneal thickness and best-fit sphere measurements were compared between the instruments. Agreement of measurements between swept source optical coherence tomography and scanning slit topography was analyzed. Intra-rater reproducibility coefficient and intraclass correlation coefficient were evaluated. In normal eyes, central corneal thickness measured by swept source optical coherence tomography was thinner compared with slit scanning topography (p topography. In keratoconus eyes, central corneal thickness was thinner on swept source optical coherence tomography than slit scanning topography (p = 0.081) and ultrasound pachymetry (p = 0.001). There were significant differences between thinnest corneal thickness, and, anterior and posterior best-fit sphere measurements between both instruments (p topography. With better reproducibility coefficients and intraclass correlation coefficients, swept source optical coherence tomography may provide a reliable alternative for measurement of corneal parameters. © 2013 The Authors. Clinical and Experimental Ophthalmology © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  14. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  15. Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed tomography

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2009-12-01

    Full Text Available "nBackground and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT and computed tomography (CT."nMaterials and Methods: Thermoluminescent dosimeters (TLD were implanted in 14 sites of RANDO phantom to measure average tissue absorbed dose in thyroid gland, parotid glands, submandibular glands, sublingual gland, lenses and buccal skin. The Promax (PLANMECA, Helsinki, Finland unit was selected for Panoramic, conventional linear tomography and cone beam computed tomography examinations and spiral Hispeed/Fxi (General Electric,USA was selected for CT examination. The average tissue absorbed doses were used for the calculation of the equivalent and effective doses in each organ."nResults: The average absorbed dose for Panoramic ranged from 0.038 mGY (Buccal skin to 0.308 mGY (submandibular gland, linear tomography ranged from 0.048 mGY (Lens to 0.510 mGY (submandibular gland,CBCT ranged from 0.322 mGY (thyroid glad to 1.144 mGY (Parotid gland and in CT ranged from 2.495 mGY (sublingual gland to 3.424 mGY (submandibular gland. Total effective dose in CBCT is 5 times greater than Panoramic and 4 times greater than linear tomography, and in CT, 30 and 22 times greater than Panoramic and linear tomography, respectively. Total effective dose in CT is 6 times greater than CBCT."nConclusion: For obtaining 3-dimensional (3D information in maxillofacial region, CBCT delivers the lower dose than CT, and should be preferred over a medical CT imaging. Furthermore, during maxillofacial imaging, salivary glands receive the highest dose of radiation.

  16. High-frequency signal paths in the TMR-86.1 experimental tomography apparatus

    International Nuclear Information System (INIS)

    Obrcian, J.; Jellus, V.; Weis, J.; Frollo, I.

    1990-01-01

    The NMR-based TMR-86.1 tomography apparatus, developed at the Institute of Measurement and Measuring Instrumentation, Slovak Academy of Sciences in Bratislava, Czechoslovakia, enables imaging of the inner structure of biological samples and human limbs no more than 110 mm in diameter, using a measuring matrix containing at most 128x128 elements. The imaged matrix can possess a maximum of 256x256 image elements with 256 brightness steps. The signal paths of the high-frequency excitation-imaging complex of the apparatus are described. Some functional blocks of the apparatus can be used without substantial modifications for the imaging of larger objects such as the human body. From the point of view of the high-frequency pulses for nonselective excitation (so-called 180deg-pulses), the excitation pulse power will have to be increased to at least 1 kW. (author). 5 figs, 7 refs

  17. Estudo de ligas de ouro por XRF e SEM-EDS

    OpenAIRE

    Coxito, Afonso Maria Teixeira

    2016-01-01

    Serve o presente estudo para testar uma metodologia para análise de ligas metálicas, em particular ligas de ouro, utilizando as técnicas de fluorescência de raios-X e microscopia electrónica de varrimento. No contexto do presente estudo, foi identificada a composição das folhas de ouro utilizadas em obras de arte. As técnicas laboratoriais utilizadas foram: Microscopia óptica; Espectroscopia de fluorescência de raios-X com dispersão de energia (EDXRF); Microscopi...

  18. Refinement procedure for the image alignment in high-resolution electron tomography

    International Nuclear Information System (INIS)

    Houben, L.; Bar Sadan, M.

    2011-01-01

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. -- Highlights: → Alignment procedure for electron tomography based on iterative tomogram contrast optimisation. → Marker-free, independent of object, little user interaction. → Accuracy competitive with fiducial marker methods and suited for high-resolution tomography.

  19. Ultrasonic computerized tomography (CT) for temperature measurements with limited projection data based on extrapolated filtered back projection (FBP) method

    International Nuclear Information System (INIS)

    Zhu Ning; Jiang Yong; Kato, Seizo

    2005-01-01

    This study uses ultrasound in combination with tomography to obtain three-dimensional temperature measurements using projection data obtained from limited projection angle. The main feature of the new computerized tomography (CT) reconstruction algorithm is to employ extrapolation scheme to make up for the incomplete projection data, it is based on the conventional filtered back projection (FBP) method while on top of that taking into account the correlation between the projection data and Fourier transform-based extrapolation. Computer simulation is conducted to verify the above algorithm. An experimental 3D temperature distribution measurement is also carried out to validate the proposed algorithm. The simulation and experimental results demonstrate that the extrapolated FBP CT algorithm is highly effective in dealing with projection data from limited projection angle

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  1. High temperature x-ray micro-tomography

    Energy Technology Data Exchange (ETDEWEB)

    MacDowell, Alastair A., E-mail: aamacdowell@lbl.gov; Barnard, Harold; Parkinson, Dilworth Y.; Gludovatz, Bernd [Lawrence Berkeley National Lab., Berkeley, CA 94720 (United States); Haboub, Abdel [Lawrence Berkeley National Lab., Berkeley, CA 94720 (United States); current –Lincoln Univ., Jefferson City, Missouri, 65101 (United States); Larson, Natalie; Zok, Frank [University California Santa Barbara, Santa Barbara CA 93106 (United States); Panerai, Francesco; Mansour, Nagi N. [NASA Ames Research Centre, Moffett Field, CA, 94035 (United States); Bale, Hrishikesh [University California Berkeley, Berkeley, CA 94720 (United States); current - Carl Zeiss X-ray Microscopy, 4385 Hopyard Rd #100, Pleasanton, CA 94588 (United States); Acevedo, Claire [Lawrence Berkeley National Lab., Berkeley, CA 94720 (United States); University California San Francisco, San Francisco, CA 94143 (United States); Liu, Dong [University of Bristol, Bristol BS8 1TH (United Kingdom); Ritchie, Robert O. [Lawrence Berkeley National Lab., Berkeley, CA 94720 (United States); University California Berkeley, Berkeley, CA 94720 (United States)

    2016-07-27

    There is increasing demand for 3D micro-scale time-resolved imaging of samples in realistic - and in many cases extreme environments. The data is used to understand material response, validate and refine computational models which, in turn, can be used to reduce development time for new materials and processes. Here we present the results of high temperature experiments carried out at the x-ray micro-tomography beamline 8.3.2 at the Advanced Light Source. The themes involve material failure and processing at temperatures up to 1750°C. The experimental configurations required to achieve the requisite conditions for imaging are described, with examples of ceramic matrix composites, spacecraft ablative heat shields and nuclear reactor core Gilsocarbon graphite.

  2. Automatic processing of multimodal tomography datasets.

    Science.gov (United States)

    Parsons, Aaron D; Price, Stephen W T; Wadeson, Nicola; Basham, Mark; Beale, Andrew M; Ashton, Alun W; Mosselmans, J Frederick W; Quinn, Paul D

    2017-01-01

    With the development of fourth-generation high-brightness synchrotrons on the horizon, the already large volume of data that will be collected on imaging and mapping beamlines is set to increase by orders of magnitude. As such, an easy and accessible way of dealing with such large datasets as quickly as possible is required in order to be able to address the core scientific problems during the experimental data collection. Savu is an accessible and flexible big data processing framework that is able to deal with both the variety and the volume of data of multimodal and multidimensional scientific datasets output such as those from chemical tomography experiments on the I18 microfocus scanning beamline at Diamond Light Source.

  3. EMPREENDEDORISMO E VALORES HUMANOS: UM ESTUDO CONCEITUAL

    Directory of Open Access Journals (Sweden)

    Luciano Vignochi

    2013-09-01

    Full Text Available O objetivo principal deste artigo foi identificar conceitos de valores humanos em publicações científicas sobre empreendedorismo. Não há um único conceito de valores humanos, gerando diversas abordagens e aplicações do termo em estudos sobre empreendedorismo. Para identificar diferenças conceituais e aplicações práticas, optou-se por realizar uma análise de conteúdo em um portfólio de artigos selecionados em bases de dados. O principal critério de seleção das publicações foi aderência ao tema. Os resultados mostram que valores podem ser definidos como: critérios de julgamento da realidade; aspectos abstratos, cognitivos e afetivos ou características determinantes da personalidade e do comportamento de empreendedores. Valores influenciam a sobrevivência do indivíduo, o crescimento do empreendimento e podem nivelar a congruência do empreendedor e seu propósito de empreendimento com os critérios de convivência social. Ainda foram discriminados resultados de estudos aplicados com vistas a destacar evidências de contribuições práticas de pesquisas sobre valores humanos em empreendedorismo. Futuras investigações para aprofundar e replicar as análises realizadas neste estudo podem contribuir com a formação de empreendedores, a realização de diagnóstico empresarial e com avanços para a consolidação um modelo de desenvolvimento de empresas baseado em valores humanos.

  4. Pictorial review: Electron beam computed tomography and multislice spiral computed tomography for cardiac imaging

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Dohmen, Pascal M.; Klessen, Christian; Wiese, Till H.; Hoffmann, Udo; Hamm, Bernd; Enzweiler, Christian N.H.

    2006-01-01

    Electron beam computed tomography (EBCT) revolutionized cardiac imaging by combining a constant high temporal resolution with prospective ECG triggering. For years, EBCT was the primary technique for some non-invasive diagnostic cardiac procedures such as calcium scoring and non-invasive angiography of the coronary arteries. Multislice spiral computed tomography (MSCT) on the other hand significantly advanced cardiac imaging through high volume coverage, improved spatial resolution and retrospective ECG gating. This pictorial review will illustrate the basic differences between both modalities with special emphasis to their image quality. Several experimental and clinical examples demonstrate the strengths and limitations of both imaging modalities in an intraindividual comparison for a broad range of diagnostic applications such as coronary artery calcium scoring, coronary angiography including stent visualization as well as functional assessment of the cardiac ventricles and valves. In general, our examples indicate that EBCT suffers from a number of shortcomings such as limited spatial resolution and a low contrast-to-noise ratio. Thus, EBCT should now only be used in selected cases where a constant high temporal resolution is a crucial issue, such as dynamic (cine) imaging. Due to isotropic submillimeter spatial resolution and retrospective data selection MSCT seems to be the non-invasive method of choice for cardiac imaging in general, and for assessment of the coronary arteries in particular. However, technical developments are still needed to further improve the temporal resolution in MSCT and to reduce the substantial radiation exposure

  5. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer.

    Science.gov (United States)

    Yang, Zhongyi; Pan, Lingling; Cheng, Jingyi; Hu, Silong; Xu, Junyan; Ye, Dingwei; Zhang, Yingjian

    2012-07-01

    To investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity = 95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. © 2012 The Japanese Urological Association.

  6. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer

    International Nuclear Information System (INIS)

    Yang Zhongyi; Pan Lingling; Cheng Jingyi; Hu Silong; Xu Junyan; Zhang Yingjian; Ye Dingwei

    2012-01-01

    The objective of this study was to investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity=95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. (author)

  7. Estudo dos estágios motivacionais no tratamento de adolescentes usuários de substâncias psicoativas ilícitas

    Directory of Open Access Journals (Sweden)

    Oliveira, Margareth da Silva

    2010-01-01

    Full Text Available A motivação vem sendo cada vez mais estudada no tratamento de adolescentes usuários de drogas. O objetivo deste trabalho foi avaliar o estágio motivacional para mudança em adolescentes infratores usuários de substâncias ilícitas que cometeram ato infracional e analisar a relação entre o estágio motivacional e a adesão ao tratamento. O estudo foi pré-experimental, realizado no Laboratório de Intervenções Cognitivas (LABICO – PUCRS. Os instrumentos foram: uma entrevista para coletar dados sociodemográficos; URICA (University of Rhode Island Change Assesment; BAI e BDI. Participaram deste estudo 103 adolescentes. O estudo mostrou que a maior parte dos adolescentes encontrava-se no estágio de pré-contemplação. A análise após a conclusão do tratamento mostrou que apenas 35 adolescentes concluíram o programa. Os dados encontrados evidenciaram que os adolescentes que pontuaram altos escores na pré-contemplação representaram substancialmente o número de desistências do programa, demonstrando a importância da identificação dos estágios motivacionais para a implementação do tratamento

  8. ESTUDO DE ETNOECODESIGN DE IMAGENS SACRAS EM GESSO DANIFICADAS E DESCARTADAS PELO USUÁRIO. ESTUDO DE MODELO SUSTENTÁVEL DE NICHO DE DESCARTE.

    Directory of Open Access Journals (Sweden)

    Paulo Sergio de Sena

    2016-10-01

    Full Text Available O Etnoecodesingn trata-se de um estudo interdisciplinar onde o dialogo envolve os critérios culturais, sociais e ambientais. Os componentes etnoecológicos do estudo das Imagens Sacras de Gesso se materializam no grupo de artesãos tradicionais locais (mais de 100 anos de exploração da técnica e recurso natural gesso. Na produção de imagens sacras, como souvenir, em Aparecida- SP, que agrega processos e materiais que contribuem significativamente para contaminação do ambiente, durante a pré-produção, produção, pós-produção e descarte, principalmente quando houve constatação, no projeto anterior, de matéria prima contaminada por metais pesados. Este trabalho trata dos possíveis impactos causados pelo descarte das imagens, uma vez danificadas, diretamente no ambiente por conta de uma prática cultural denominada de “Santa Cruz” e vem contribuir para o estudo comparado dos atuais modelos de nicho de descarte e a proposta de um modelo mais sustentável para a Santa Cruz.

  9. Festivais musicais : um estudo sob a ótica do turismo

    OpenAIRE

    Ruas, Rayane

    2014-01-01

    Este trabalho trata-se de uma pesquisa de caráter qualitativo, baseada no método hipotético-dedutivo, que busca analisar os festivais de música enquanto encontros que permitem a ruptura do cotidiano proporcionando uma experiência do turismo. Primeiramente foi realizada uma pesquisa exploratória explicativa acerca do tema o que delimitou o seu objeto de estudo. O recorte do objeto de estudo foram os festivais de música desde o Festival de Monterey em 1967 até os dias atuais. Durante a pesquisa...

  10. Radiation dose during tomography of the petrous bone. Experimental investigations with film dosimetry on an Alderson phantom

    Energy Technology Data Exchange (ETDEWEB)

    Grehn, S.

    1988-06-01

    Using filmdosimetry and an Alderson skull phantom, the iso-dose distribution during tomography of the petrous bone was investigated. We were particularly concerned with the radiation dose to the lens of the eye, the critical organ in the skull, and to the inner ear, using different types of examination and various positions of the skull. The choice of suitable film material and standardisation against TLD measurements is crucial for the accuracy of film dosimetry, allowing for correction of film blackening in relation to varying energies. Tomography of the petrous bone in the prone position produced a reduction in radiation dose to the eye to only 1 to 4% of the dose incident on the occiput. In this way, and using high definition screen and grinds, it is possible to obtain optimal tomographic images despite drastic reduction of the scattered radiation to the eye. Radiation dose to the inner ear is greatly below any significant somatic dose, irrespective of projection or technique. Special measures to reduce radiation to the inner ear are neither effective nor sensible.

  11. Regeneração óssea guiada com o uso de membrana de copolímero PLA/PGA em levantamento da membrana do seio maxilar: estudo experimental com análises histomorfométrica e imunoistoquímica

    OpenAIRE

    Bomfim, Bianca Bravim [UNESP

    2015-01-01

    A utilização de biomateriais em implantodontia, principalmente em casos em que o leito receptor do implante apresenta quantidade e qualidade ósseas inadequadas, se torna importante. Diversos estudos mostram a possibilidade do usar copolímeros de PLA/PGA, no entanto, estes mesmos estudos mostram que a proporção de PLA e PGA irá influenciar a taxa de degradação do copolímero. Portanto, objetivo desse estudo foi avaliar o comportamento biológico do copolímero de PLA/PGA como substitutos ósseos p...

  12. Electrical impedance tomography spectroscopy method for characterising particles in solid-liquid phase

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Yanlin [Department of Thermal Energy Engineering, College of Mechanical and Transportation Engineering, China University of Petroleum, Beijing, 102249 (China); Wang, Mi [Institute of Particle Science and Engineering, School of Process, Environmental and Materials Engineering, University of Leeds, Leeds LS2 9JT (China); Yao, Jun [School of Energy Research, Xiamen University, Xiamen 361005 (China)

    2014-04-11

    Electrical impedance tomography (EIT) is one of the process tomography techniques to provide an on-line non-invasive imaging for multiphase flow measurement. With EIT measurements, the images of impedance real part, impedance imaginary part, phase angle, and magnitude can be obtained. However, most of the applications of EIT in the process industries rely on the conductivity difference between two phases in fluids to obtain the concentration profiles. It is not common to use the imaginary part or phase angle due to the dominant change in conductivity or complication in the use of other impedance information. In a solid-liquid two phases system involving nano- or submicro-particles, characterisation of particles (e.g. particle size and concentration) have to rely on the measurement of impedance phase angle or imaginary part. Particles in a solution usually have an electrical double layer associated with their surfaces and can form an induced electrical dipole moment due to the polarization of the electrical double layer under the influence of an alternating electric field. Similar to EIT, electrical impedance spectroscopy (EIS) measurement can record the electrical impedance data, including impedance real part, imaginary part and phase angle (θ), which are caused by the polarization of the electrical double layer. These impedance data are related to the particle characteristics e.g. particle size, particle and ionic concentrations in the aqueous medium, therefore EIS method provides a capability for characterising the particles in suspensions. Electrical impedance tomography based on EIS measurement or namely, electrical impedance tomography spectroscopy (EITS) could image the spatial distribution of particle characteristics. In this paper, a new method, including test set-up and data analysis, for characterisation of particles in suspensions are developed through the experimental approach. The experimental results on tomographic imaging of colloidal particles

  13. Estudo eletrorretinográfico de visão cromática Electroretinographic study of chromatic vision

    Directory of Open Access Journals (Sweden)

    Daniela Cavalcanti Ferrara de Almeida Cunha

    2006-12-01

    Full Text Available OBJETIVO: O objetivo deste estudo é descrever o traçado eletrorretinográfico no gambá sul-americano (Didelphis aurita obtido com estímulo cromático de comprimento de onda seletivo. O eletrorretinograma é o registro das variações de voltagem nas células retinianas, desencadeadas por estímulo luminoso. O eletrorretinograma representa a atividade elétrica combinada de diferentes células, e sofre variações dependendo da fisiologia retiniana e do método de exame. MÉTODOS: Foram registrados os eletrorretinogramas de seis animais em adaptação ao escuro utilizando filtros cromáticos Kodak Wratten®, e registrada a sensibilidade espectral para comprimentos de onda específicos nas faixas de cores do azul, verde, amarelo, laranja e vermelho. RESULTADOS: Os resultados eletrorretinográficos mais consistentes foram obtidos quando o animal foi estimulado por faixas espectrais seletivas, ao invés de luz branca; e são consistentes com a curva de absorbância das opsinas descritas em fotorreceptores de marsupiais. Estudos prévios sugeriram a tricromacia dos marsupiais por microespectrofotometria de opsinas e imuno-histoquímica de retina. Esse fundamento morfológico não tinha demonstração fisiológica eletrorretinográfica, até este estudo. CONCLUSÃO: O gambá sul-americano tem se mostrado interessante como animal experimental no estudo comparativo da fisiologia visual em mamíferos, especialmente no estudo filogenético da visão cromática. Os marsupiais apresentam um modelo retiniano que superpõe os sistemas fotópico e escotópico; e o gênero Didelphis conserva características encontradas em fósseis do período pleoceno. Portanto, o sistema visual de um marsupial resgata características dos primórdios da evolução dos mamíferos, até o desenvolvimento dos padrões retinianos modernos.PURPOSE: To describe the electroretinogram of the South-American opossum (Didelphis aurita obtained by chromatic stimulus of specific

  14. Colestase neonatal prolongada: estudo prospectivo

    Directory of Open Access Journals (Sweden)

    PRADO Elizabeth Teixeira Mendes Livramento

    1999-01-01

    Full Text Available Em razão da urgência de se decidir por um tratamento clínico ou por uma intervenção cirúrgica imediata, o estudo da colestase neonatal prolongada envolve dois objetivos básicos: o diagnóstico diferencial entre atresia biliar e hepatite neonatal e a pesquisa dos agentes etiológicos associados. Desta maneira, através de estudo prospectivo desenvolvido na década de 1970, foram avaliadas 77 crianças portadoras de colestase neonatal prolongada para estabelecer o diagnóstico diferencial entre atresia biliar e hepatite neonatal e, numa segunda fase, 108 crianças, visando esclarecer a etiopatogenia da colestase neonatal prolongada. Os resultados do diagnóstico diferencial revelaram que, dos 18 atributos avaliados, apenas oito mostraram-se bons indicadores de atresia biliar, em ordem decrescente: ductos proliferados (espaço-porta, fibrose (espaço-porta, colestase (espaço-porta, cor das fezes -- acolia, hepatomegalia, colestase canalicular (lóbulo, infiltrado (espaço-porta, células gigantes (lóbulo. Estes oito atributos foram então compostos, mediante uma ponderação, em um único indicador de grande poder discriminativo, capaz de decidir o diagnóstico diferencial em 99% dos casos. Quanto à etiopatogenia, registrou-se: vírus rubéola 0%, vírus herpes simples 0%, listeriose 0%, citomegalovirose 2,2%, vírus hepatite B 2,4%, toxoplasmose 2,8%, deficiência de alfa-1-antitripsina 13,1%, sífilis 21,1 %, auto-anticorpos hepáticos 58,4%. O trabalho desenvolvido mostra que as 8 variáveis mais decisivas, como indicadoras diferenciais entre atresia biliar e hepatite neonatal, permanecem como índices fundamentais, auxiliando, em conjunto com novos métodos diagnósticos, na composição de uma estratégia multifatorial cada vez menos invasiva e mais precisa. O estudo da etiopatogenia, dependente das condições epidemiológicas locais e da época, com a introdução de novos métodos diagnósticos, torna-se atualmente cada vez mais

  15. Digital hilar tomography. Comparison with conventional technique

    International Nuclear Information System (INIS)

    Schaefer, C.B.; Braunschweig, R.; Teufl, F.; Kaiser, W.; Claussen, C.D.

    1993-01-01

    The aim of the following study was to compare conventional hilar tomography and digital hilar tomography. 20 patients were examined both with conventional and digital hilar tomography using the same tomographic technique and the identical exposure dose. All patients underwent computed tomography of the chest as a golden standard. The digital technique, especially the edge-enhanced image version, showed superior image quality. ROC-analysis by 4 readers found equal diagnostic performance without any statistical difference. Digital hilar tomography shows a superior and constant image quality and lowers the rate of re-exposure. Therefore, digital hilar tomography is the preferable method. (orig.) [de

  16. Electrical impedance tomography of electrolysis.

    Directory of Open Access Journals (Sweden)

    Arie Meir

    Full Text Available The primary goal of this study is to explore the hypothesis that changes in pH during electrolysis can be detected with Electrical Impedance Tomography (EIT. The study has relevance to real time control of minimally invasive surgery with electrolytic ablation. To investigate the hypothesis, we compare EIT reconstructed images to optical images acquired using pH-sensitive dyes embedded in a physiological saline agar gel phantom treated with electrolysis. We further demonstrate the biological relevance of our work using a bacterial E.Coli model, grown on the phantom. The results demonstrate the ability of EIT to image pH changes in a physiological saline phantom and show that these changes correlate with cell death in the E.coli model. The results are promising, and invite further experimental explorations.

  17. Tomography of nonclassical states

    NARCIS (Netherlands)

    Bazrafkan, MR; Man'ko, [No Value

    2003-01-01

    A review of the symplectic tomography method is presented. Superpositions of different types of photon states are considered within the framework of the tomography approach. Such nonclassical photon states as even and odd coherent states, crystallized Schrodinger cat states, and other superposition

  18. ANÁLISE DE COMPONENTES PRINCIPAIS APLICADA À CIÊNCIA DE ALIMENTOS: ESTUDO DE CASO COM PEQUI

    Directory of Open Access Journals (Sweden)

    Aline Inacio Alves

    2017-01-01

    Full Text Available Com este trabalho se objetivou avaliar a potencialidade da análise de componentes principais para a interpretação de resultados de um experimento com microencapsulamento de pequi. O experimento foi realizado no laboratório de Tecnologia de Frutas e Hortaliças do Departamento de Engenharia de Alimentos da Universidade Federal de Viçosa. As variáveis utilizadas neste trabalho foram extraídas de um estudo físico-químico e morfológico obtidos a partir de extrato de pequi. A análise de componentes foi realizada com base na matriz de correlação existente entre as componentes e as variáveis reais transformadas, de forma a identificar novas variáveis que explicam a maior parte da variabilidade, gerando-se novos valores para cada parcela experimental correspondente às componentes principais. Para cada temperatura utilizada no trabalho foram ajustadas apenas duas componentes capazes de explicar mais de 90% da variância dos dados originais. A análise de componentes principais foi eficiente neste estudo, gerando componentes interpretáveis reduzindo a dimensionalidade do problema se a perda de informações.

  19. Modelo experimental de fundoplicatura gastroesofágica em ratos: estudo manométrico e histológico do esôfago Experimental model of gastric-esophageal fundoplication in rats: manometric and histological study of the esophagus

    Directory of Open Access Journals (Sweden)

    Sérgio Luis Rocha

    2004-04-01

    Full Text Available OBJETIVO: O presente estudo objetiva avaliar alguns aspectos decorrentes da fundoplicatura em ratos, com técnica de Nissen, através da análise histológica do esôfago distal e estudo manométrico do esfíncter esofágico inferior (EEI, bem como da avaliação da variação do peso dos ratos submetidos ao procedimento, com diferentes dias de evolução. MÉTODOS: Utilizaram-se 70 ratos Wistar, machos, com idade entre 100 e 130 dias e peso entre 250 e 300 g, divididos em dois grupos. O grupo experimento foi composto por 60 ratos, subdivididos em 6 subgrupos de acordo com o tempo de aferição manométrica pós-operatória: 02, 07, 14, 21, 28 e 40 dias, e submetido a fundoplicatura com posterior análise manométrica do EEI e histológica do esôfago distal. O grupo controle foi composto pelos 10 animais restantes, submetido apenas a laparotomia com manipulação da região es��fago-gástrica, e realizaram-se as mesmas análises. RESULTADOS: Evidenciou-se na análise histológica, edema estatisticamente significativo (p=0,0000 nos subgrupos 02 e 07 dias, acompanhado de perda de peso. Observou-se significância estatística no estudo manométrico em todos os subgrupos comparados ao controle (p t c=+2,132. CONCLUSÃO: Após fundoplicatura de Nissen em ratos, a pressão no EEI não retorna aos níveis do controle até o 40º pós-operatório. O edema correlacionado à perda de peso e ao aumento da pressão no EEI pode ser a principal variável relacionada à possível disfagia.PURPOSE: The aim of this experimental study is to evaluate the outcomes of having Nissen fundoplication done on rats through the histological analysis of the distal esophagus and manometric study of the lower esophageal sphincter (LES, as well as the evaluation of weight variation of the rats subjected to this procedure, in distinct days after surgery. METHODS: Have been used 70 male Wistar rats, at the ages of 100 to 130 days , weighing from 250 to 300 grams and divided

  20. Novas tecnologias no estudo de ondas sonoras

    Directory of Open Access Journals (Sweden)

    Marisa Almeida Cavalcante

    2013-10-01

    Full Text Available http://dx.doi.org/10.5007/2175-7941.2013v30n3p579 O presente trabalho propõe a construção de um Tubo de Kundt adaptado às novas tecnologias disponíveis para o ensino de física. Tem como principal objetivo utilizar a placa Arduino em experimentos didáticos envolvendo o estudo de ondas sonoras. O Arduino é uma placa de controle I/O baseada no micro-controlador Atmega (Atmel e foi projetado inicialmente para fins didáticos. O fato da linguagem de programação utilizada e hardware serem do tipo open source (código aberto possibilitou sua ampla difusão em diversas áreas. Uma das intenções deste projeto é difundir o uso deste recurso para fins educacionais e particularmente no estudo de ondas sonoras estacionarias em tubos, contribuindo com a melhora na abordagem deste conteúdo no ensino e aprendizagem de Física.

  1. ¹⁸F-fluorodeoxyglucose positron emission tomography-computed tomography for the evaluation of bone metastasis in patients with gastric cancer.

    Science.gov (United States)

    Ma, Dae Won; Kim, Jie-Hyun; Jeon, Tae Joo; Lee, Yong Chan; Yun, Mijin; Youn, Young Hoon; Park, Hyojin; Lee, Sang In

    2013-09-01

    The roles of positron emission tomography and bone scanning in identifying bone metastasis in gastric cancer are unclear. We compared the usefulness of positron emission tomography-computed tomography and scanning in detecting bone metastasis in gastric cancer. Data from 1485 patients diagnosed with gastric cancer who had undergone positron emission tomography-computed tomography and scanning were reviewed. Of 170 enrolled patients who were suspected of bone metastasis in either positron emission tomography or scanning, 81.2% were confirmed to have bone metastasis. The sensitivity, specificity, and accuracy were 93.5%, 25.0%, and 80.6%, respectively, for positron emission tomography and 93.5%, 37.5%, and 82.9%, respectively, for scanning. 87.7% of patients with bone metastasis showed positive findings on two modalities. 15.0% of solitary bone metastases were positive on positron emission tomography only. Positron emission tomography was superior to scanning for the detection of synchronous bone metastasis, but the two modalities were similar for the detection of metachronous bone metastasis. The concordance rate of response assessment after treatment between two modalities was moderate. Positron emission tomography-computed tomography may be more effective for the diagnosis of bone metastasis in the initial staging workup. Conversely, bone scanning and positron emission tomography-computed tomography may be similarly effective for the detection of metachronous bone metastasis. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  2. Investigation of retinal morphology alterations using spectral domain optical coherence tomography in a mouse model of retinal branch and central retinal vein occlusion.

    Directory of Open Access Journals (Sweden)

    Andreas Ebneter

    Full Text Available Retinal vein occlusion is a leading cause of visual impairment. Experimental models of this condition based on laser photocoagulation of retinal veins have been described and extensively exploited in mammals and larger rodents such as the rat. However, few reports exist on the use of this paradigm in the mouse. The objective of this study was to investigate a model of branch and central retinal vein occlusion in the mouse and characterize in vivo longitudinal retinal morphology alterations using spectral domain optical coherence tomography. Retinal veins were experimentally occluded using laser photocoagulation after intravenous application of Rose Bengal, a photo-activator dye enhancing thrombus formation. Depending on the number of veins occluded, variable amounts of capillary dropout were seen on fluorescein angiography. Vascular endothelial growth factor levels were markedly elevated early and peaked at day one. Retinal thickness measurements with spectral domain optical coherence tomography showed significant swelling (p<0.001 compared to baseline, followed by gradual thinning plateauing two weeks after the experimental intervention (p<0.001. Histological findings at day seven correlated with spectral domain optical coherence tomography imaging. The inner layers were predominantly affected by degeneration with the outer nuclear layer and the photoreceptor outer segments largely preserved. The application of this retinal vein occlusion model in the mouse carries several advantages over its use in other larger species, such as access to a vast range of genetically modified animals. Retinal changes after experimental retinal vein occlusion in this mouse model can be non-invasively quantified by spectral domain optical coherence tomography, and may be used to monitor effects of potential therapeutic interventions.

  3. High resolution X-ray tomography for stationary multiphase flows

    International Nuclear Information System (INIS)

    Schmitz, D.; Reinecke, N.; Petritsch, G.; Mewes, D.

    1998-01-01

    The high resolution which can be obtained by computer assisted tomography is used to investigate the liquid distribution and void fraction in random and structured packing. With a spatial resolution of 0.4x0.4mm 2 it is possible even to detect thin liquid films on structured packings. The experimental set-up consists of a custom-built second generation tomograph. The imaged object consists of a column filled with either a random ceramic packing of spheres or a structured metal packing. The liquid and void fraction distribution in random and structured packings with a quiescent gaseous phase is visualized. The water/air system is used. The liquid distributor consists of a perforated plate. The experimental hold-up values averaged over the column cross-section are in good agreement with empirical equations. (author)

  4. Fluorescence molecular tomography in the presence of background fluorescence

    International Nuclear Information System (INIS)

    Soubret, Antoine; Ntziachristos, Vasilis

    2006-01-01

    Fluorescence molecular tomography is an emerging imaging technique that resolves the bio-distribution of engineered fluorescent probes developed for in vivo reporting of specific cellular and sub-cellular targets. The method can detect fluorochromes in picomole amounts or less, imaged through entire animals, but the detection sensitivity and imaging performance drop in the presence of background, non-specific fluorescence. In this study, we carried out a theoretical and an experimental investigation on the effect of background fluorescence on the measured signal and on the tomographic reconstruction. We further examined the performance of three subtraction methods based on physical models of photon propagation, using experimental data on phantoms and small animals. We show that the data pre-processing with subtraction schemes can improve image quality and quantification when non-specific background florescence is present

  5. Ana Carolina Escosteguy: Cenários dos estudos culturais

    Directory of Open Access Journals (Sweden)

    Thaisa Cristina Bueno

    2015-12-01

    Full Text Available Autora do livro “Cartografia dos Estudos Culturais”, “Comunicação e recepção” (em coautoria com Nilda Jacks, “Leituras em comunicação, cultura e tecnologia”, além de coautora e organizadora em outras obras de referência sobre o tema cultura e comunicação no Brasil, Ana Carolina Escosteguy é hoje um dos nomes mais importantes quando se pensa em Estudos Culturais no país. Doutora em Ciências da Comunicação pela Universidade de São Paulo (2000, com pós-doutorado no CAMRI (Communication and Media Research Institute, associado ao Department of Journalism and Mass Communication da School of Media, Art and Design da University of Westminster (UK, Ana Carolina Escosteguy é professora titular da Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS e bolsista produtividade em pesquisa do CNPq, desde março 2001. Nesta entrevista ela discute pontos sensíveis da área, entre eles o pouco destaque das pesquisas desse campo têm tido no Jornalismo, o fato de a base teórica ser bem mais ampla que os tradicionais estudos de recepção a que são comumente aproximados, não se nega a tratar das confusões com a folkcomunicação, bem como as próprios limites e intersecções desse campo de estudos. Durante esta conversa, aproveita para apontar as obras que considera essenciais para adentrar na área e mostra coragem e segurança para se colocar como uma pesquisadora que busca entender o tempo atual, as tecnologias e as rupturas a partir da perspectiva do usuário. Confiram:

  6. Quantification in emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-11-01

    The objective of this lecture is to understand the possibilities and limitations of the quantitative analysis of single photon emission computed tomography (SPECT) and positron emission tomography (PET) images. It is also to identify the conditions to be fulfilled to obtain reliable quantitative measurements from images. Content: 1 - Introduction: Quantification in emission tomography - definition and challenges; quantification biasing phenomena 2 - Main problems impacting quantification in PET and SPECT: problems, consequences, correction methods, results (Attenuation, scattering, partial volume effect, movement, un-stationary spatial resolution in SPECT, fortuitous coincidences in PET, standardisation in PET); 3 - Synthesis: accessible efficiency, know-how, Precautions, beyond the activity measurement

  7. Functional high-resolution computed tomography of pulmonary vascular and airway reactions. Experimental results. Funktionelle HR-CT der Lunge. Experimentelle Untersuchungen pulmonaler Gefaess- und Atemwegsreaktionen

    Energy Technology Data Exchange (ETDEWEB)

    Herold, C.J. (Universitaetsklinik fuer Radiodiagnostik, Vienna (Austria) Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Radiology); Brown, R.H. (Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Radiology Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Anesthesiology and Intensive Care Medicine Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Physiology); Wetzel, R.C.; Herold, S.M. (Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Anesthesiology and Intensive Care Medicine); Zeerhouni, E.A. (Johns Hopkins Medical Institutions, Baltimore, MD (United States). Dept. of Radiology)

    1993-03-01

    We describe the use of high-resolution computed tomography (HRCT) for assessment of the function of pulmonary vessels and airways. With its excellent spatial resolution, HRCT is able to demonstrate pulmonary structures as small as 300 [mu]m and can be used to monitor changes following various stimuli. HRCT also provides information about structures smaller than 300 [mu]m through measurement of parenchymal background density. To date, sequential, spiral and ultrafast HRCT techniques have been used in a variety of challenges to gather information about the anatomical correlates of traditional physiological measurements, thus making anatomical-physiological correlation possible. HRCT of bronchial reactivity can demonstrate the location and time course of aerosol-induced broncho-constriction and may show changes not apparent on spirometry. HRCT of the pulmonary vascular system visualized adaptations of vessels during hypoxia and intravascular volume loading and elucidates cardiorespiratory interactions. Experimental studies provide a basis for potential clinical applications of this method. (orig.).

  8. Enxertos valvares aórticos homólogos: estudo experimental em cães

    Directory of Open Access Journals (Sweden)

    Rui Manoel Sequeira de ALMEIDA

    1998-01-01

    Full Text Available Vinte cães foram divididos em dois grupos de dez, sendo um o grupo doador (Grupo 1 e o outro, o receptor (Grupo 2. Todos os animais do grupo 1 foram submetidos a uma toracotomia mediana e sacrificados, para a retirada do coração e da valva aórtica; os cães do grupo 2 foram submetidos a uma laparotomia mediana para o implante das valvas aórticas homólogas na aorta abdominal infra-renal. O peso médio dos cães do grupo 1 era de 5,5 ± 1,7 kg e o diâmetro médio da aorta descendente de 11,8 ± 1,4 mm. No grupo 2 o peso médio era de 11,9 ± 2,3 kg e o diâmetro da aorta abdominal, de 8,8 ± 1,2 mm. A operação no grupo 2 teve como intercorrência a lesão do conduto linfático, em 4 casos, sendo o tempo médio de isquemia, durante o implante do enxerto homólogo, de 37,6 ± 13,3 min. Os animais foram acompanhados por um período de trinta dias, à exceção de 3. Um cão faleceu no décimo dia de pós-operatório por infarto da artéria mesentérica inferior; um segundo foi sacrificado no décimo quarto dia, por apresentar deiscência parcial da ferida cirúrgica, e o terceiro se evadiu no vigésimo quinto dia de pós-operatório. Dois animais apresentaram deiscência da incisão cirúrgica, levando a uma morbidade de 20%. No trigésimo dia, todos os animais sobreviventes foram submetidos a nova laparotomia, quando foram analisados as aderências da cavidade abdominal e o hematoma em torno do enxerto homólogo, e foram aferidas e registradas as pressões proximal e distal ao enxerto valvar (gradiente médio de 25 mmHg. Após o sacrifício do animal, os enxertos foram explantados para a análise das válvulas que eram normais, à excepção de dois, que apresentavam trombos e retração com fibrose, porém, sem significação clínica. Conclui-se que o modelo é viável para estudos futuros sobre valvas aórticas homólogas.The aim of this research was to develop an experimental model, with dogs, to study homologous aortic valve grafts. A

  9. Optical tomography of the aurora and EISCAT

    Directory of Open Access Journals (Sweden)

    H. U. Frey

    1998-10-01

    Full Text Available Tomographic reconstruction of the three-dimensional auroral arc emission is used to obtain vertical and horizontal distributions of the optical auroral emission. Under the given experimental conditions with a very limited angular range and a small number of observers, algebraic reconstruction methods generally yield better results than transform techniques. Different algebraic reconstruction methods are tested with an auroral arc model and the best results are obtained with an iterative least-square method adapted from emission-computed tomography. The observation geometry used during a campaign in Norway in 1995 is tested with the arc model and root-mean-square errors, to be expected under the given geometrical conditions, are calculated. Although optimum geometry was not used, root-mean-square errors of less than 2% for the images and of the order of 30% for the distribution could be obtained. The method is applied to images from real observations. The correspondence of original pictures and projections of the reconstructed volume is discussed, and emission profiles along magnetic field lines through the three-dimensionally reconstructed arc are calibrated into electron density profiles with additional EISCAT measurements. Including a background profile and the temporal changes of the electron density due to recombination, good agreement can be obtained between measured profiles and the time-sequence of calculated profiles. These profiles are used to estimate the conductivity distribution in the vicinity of the EISCAT site. While the radar can only probe the ionosphere along the radar beam, the three-dimensional tomography enables conductivity estimates in a large area around the radar site.Key words. Tomography · Aurora · EISCAT · Ionosphere · Conductivity

  10. Optical tomography of the aurora and EISCAT

    Directory of Open Access Journals (Sweden)

    H. U. Frey

    Full Text Available Tomographic reconstruction of the three-dimensional auroral arc emission is used to obtain vertical and horizontal distributions of the optical auroral emission. Under the given experimental conditions with a very limited angular range and a small number of observers, algebraic reconstruction methods generally yield better results than transform techniques. Different algebraic reconstruction methods are tested with an auroral arc model and the best results are obtained with an iterative least-square method adapted from emission-computed tomography. The observation geometry used during a campaign in Norway in 1995 is tested with the arc model and root-mean-square errors, to be expected under the given geometrical conditions, are calculated. Although optimum geometry was not used, root-mean-square errors of less than 2% for the images and of the order of 30% for the distribution could be obtained. The method is applied to images from real observations. The correspondence of original pictures and projections of the reconstructed volume is discussed, and emission profiles along magnetic field lines through the three-dimensionally reconstructed arc are calibrated into electron density profiles with additional EISCAT measurements. Including a background profile and the temporal changes of the electron density due to recombination, good agreement can be obtained between measured profiles and the time-sequence of calculated profiles. These profiles are used to estimate the conductivity distribution in the vicinity of the EISCAT site. While the radar can only probe the ionosphere along the radar beam, the three-dimensional tomography enables conductivity estimates in a large area around the radar site.

    Key words. Tomography · Aurora · EISCAT · Ionosphere · Conductivity

  11. Design of optoelectronic system for optical diffusion tomography

    Directory of Open Access Journals (Sweden)

    Erakhtin Igor

    2017-01-01

    Full Text Available This article explores issues connected with the circuit design of a device for optical diffusion tomography, which we are currently designing. We plan to use the device in experimental studies for the development of a faster method of brain hematoma detection. We reviewed currently existing methods for emergency diagnosis of hematomas, primarily the Infrascanner model 2000, for which we identified weaknesses, and outlined suggestions for improvements. This article describes the method of scanning tissues based on a triangulated arrangement of sources and receivers of optical radiation, and it discusses the optoelectronic system that implements that principle.

  12. A Monte Carlo simulation of the possible use of Positron Emission Tomography in proton radiotherapy

    International Nuclear Information System (INIS)

    Del Guerra, Alberto; Di Domenico, Giovanni; Gambaccini, Mauro; Marziani, Michele

    1994-01-01

    We have used the Monte Carlo technique to evaluate the applicability of Positron Emission Tomography to in vivo dosimetry for proton radiotherapy. A fair agreement has been found between Monte Carlo results and experimental data. The simulation shows that PET can be useful especially for in vivo Bragg's peak localization. ((orig.))

  13. Tomography

    International Nuclear Information System (INIS)

    Allan, C.J.; Keller, N.A.; Lupton, L.R.; Taylor, T.; Tonner, P.D.

    1984-10-01

    Tomography is a non-intrusive imaging technique being developed at CRNL as an industrial tool for generating quantitative cross-sectional density maps of objects. Of most interest is tomography's ability to: distinguish features within complex geometries where other NDT techniques fail because of the complexity of the geometry; detect/locate small density changes/defects within objects, e.g. void fraction measurements within thick-walled vessels, shrink cavities in castings, etc.; provide quantitative data that can be used in analyses, e.g. of complex processes, or fracture mechanics; and provide objective quantitative data that can be used for (computer-based) quality assurance decisions, thereby reducing and in some cases eliminating the present subjectivity often encountered in NDT. The CRNL program is reviewed and examples are presented to illustrate the potential and the limitations of the technology

  14. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using 18 F-fluorodeoxyglucose positron emission tomography-computed tomography

    International Nuclear Information System (INIS)

    Kimizuka, Yoshifumi; Hasegawa, Naoki; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko

    2013-01-01

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess

  15. Low-dose x-ray phase-contrast and absorption CT using equally sloped tomography

    International Nuclear Information System (INIS)

    Fahimian, Benjamin P; Miao Jianwei; Mao Yu; Cloetens, Peter

    2010-01-01

    Tomographic reconstruction from undersampled and noisy projections is often desirable in transmission CT modalities for purposes of low-dose tomography and fast acquisition imaging. However under such conditions, due to the violation of the Nyquist sampling criteria and the presence of noise, reconstructions with acceptable accuracy may not be possible. Recent experiments in transmission electron tomography and coherent diffraction microscopy have shown that the technique of equally sloped tomography (EST), an exact tomographic method utilizing an oversampling iterative Fourier-based reconstruction, provides more accurate image reconstructions when the number of projections is significantly undersampled relative to filtered back projection and algebraic iterative methods. Here we extend this technique by developing new reconstruction algorithms which allow for the incorporation of advanced mathematical regularization constraints, such as the nonlocal means total variational model, in a manner that is consistent with experimental projections. We then evaluate the resulting image quality of the developed algorithm through simulations and experiments at the European Synchrotron Radiation Facility on image quality phantoms using the x-ray absorption and phase contrast CT modalities. Both our simulation and experimental results have indicated that the method can reduce the number of projections by 60-75% in parallel beam modalities, while achieving comparable or better image quality than the conventional reconstructions. As large-scale and compact synchrotron radiation facilities are currently under rapid development worldwide, the implementation of low-dose x-ray absorption and phase-contrast CT can find broad applications in biology and medicine using these advanced x-ray sources.

  16. Benchmarking e a indústria do conhecimento: um estudo de caso

    OpenAIRE

    Maciel Filho, Adalberto Rego; Aquino, Miriam Cunha de; Sales, Nayade Kennedy

    2016-01-01

    Resumo Estudo de caso das Bibliotecas Indústria do Conhecimento (IDCs) do sistema do Serviço Social da Indústria-Sesi localizadas em Alagoas (25), Paraíba (10),Pernambuco (18), Rio Grande do Norte (10), especificamente as IDCs Públicas, objetivando analisar o seu desempenho e apresentar oportunidades para incremento de frequência utilizando benchmarking. Inclui revisão de literatura de projetos nacionais de uso de benchmarking, bem como estudos e considerações sobre esse processo. Para anális...

  17. The value of positron emission tomography/computed tomography for evaluating metastatic disease in patients with pancreatic cancer.

    Science.gov (United States)

    Kim, Mi-Jin; Lee, Kwang Hyuck; Lee, Kyu Taek; Lee, Jong Kyun; Ku, Bon-Ho; Oh, Cho-Rong; Heo, Jin Seok; Choi, Seong-Ho; Choi, Dong Wook

    2012-08-01

    Routine application of positron emission tomography/computed tomography (PET/CT) for pancreatic cancer staging remains a controversial approach. The purpose of this study was to reassess the clinical impact of PET/CT for the detection of distant metastasis of pancreatic cancer. From January 2006 to June 2009, 125 patients with histologically proven pancreatic cancer that had undergone PET/CT at our hospital were retrospectively reviewed. To evaluate the clinical efficacy of PET/CT on the management plan, the post-PET/CT management plans were compared with the pre-PET/CT management plans. After the conventional staging workup, we determined that 76 patients (60.8%) had resectable lesions, whereas 48 patients had unresectable lesions. One patient underwent explorative laparotomy due to equivocal resectability. Positron emission tomography/computed tomography diagnosed distant metastasis in only 2 (2.6%) of the 76 patients with resectable lesions, and these patients did not undergo unnecessary surgical treatment. Complete resection was not performed in 8 of the 74 operative patients because they had distant metastasis detected during the operative procedure. Positron emission tomography/computed tomography diagnosed distant metastasis in 32 of the 44 patients with metastatic lesions that were histologically shown to have sensitivity of 72.7%. Positron emission tomography/computed tomography has a limited role in the evaluation of metastatic disease from pancreatic cancer.

  18. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Harris, L.D.; Ritman, E.L.; Robb, R.A.

    1987-01-01

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  19. Interpretation of atom probe tomography data for the intermetallic TiAl+Nb by means of field evaporation simulation

    KAUST Repository

    Boll, Torben; Al-Kassab, Talaat

    2013-01-01

    In this paper simulations of the field evaporation process during field ion microscopy (FIM) and atom probe tomography (APT) are presented and compared with experimental data. The Müller-Schottky-model [1] was extended to include the local atomic

  20. O adolescer como portadora de HIV/AIDS : um estudo com adolescentes e suas cuidadoras-familiares

    OpenAIRE

    Ana Amélia Antunes Lima

    2006-01-01

    Trata-se de um estudo exploratório com abordagem qualitativa que aborda a questão do adolescer com HIV/AIDS. Os objetivos do estudo foram: conhecer como ocorre o processo de adolescer para as adolescentes portadoras de HIV/AIDS por transmissão materno-infantil e conhecer como os cuidadores-familiares dessas adolescentes percebem o processo de adolescer com HIV/AIDS. Participaram do estudo sete sujeitos, sendo quatro adolescentes portadoras de HIV/AIDS e três cuidadoras, residentes em Porto Al...

  1. Positron emission tomography

    International Nuclear Information System (INIS)

    Dvorak, O.

    1989-01-01

    The principle is briefly described of positron emission tomography, and its benefits and constraints are listed. It is emphasized that positron emission tomography (PET) provides valuable information on metabolic changes in the organism that are otherwise only very difficult to obtain, such as brain diagnosis including relationships between mental disorders and the physiology and pathophysiology of the brain. A PET machine is to be installed in Czechoslovakia in the near future. (L.O.)

  2. Positron Emission Tomography imaging with the SmartPET system

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.J. [Department of Physics, University of Liverpool, Liverpool, Merseyside L69 7ZE (United Kingdom)], E-mail: cooperrj@ornl.gov; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Grint, A.N.; Harkness, L.J.; Nolan, P.J.; Oxley, D.C.; Scraggs, D.P.; Mather, A.R. [Department of Physics, University of Liverpool, Liverpool, Merseyside L69 7ZE (United Kingdom); Lazarus, I.; Simpson, J. [STFC Daresbury Laboratory, Daresbury, Warrington, Cheshire WA4 4AD (United Kingdom)

    2009-07-21

    The Small Animal Reconstruction Tomograph for Positron Emission Tomography (SmartPET) project is the development of a small animal Positron Emission Tomography (PET) demonstrator based on the use of High-Purity Germanium (HPGe) detectors and state of the art digital electronics. The experimental results presented demonstrate the current performance of this unique system. By performing high precision measurements of one of the SmartPET HPGe detectors with a range of finely collimated gamma-ray beams the response of the detector as a function of gamma-ray interaction position has been quantified, facilitating the development of parametric Pulse Shape Analysis (PSA) techniques and algorithms for the correction of imperfections in detector performance. These algorithms have then been applied to data from PET imaging measurements using two such detectors in conjunction with a specially designed rotating gantry. In this paper we show how the use of parametric PSA approaches allows over 60% of coincident events to be processed and how the nature and complexity of an event has direct implications for the quality of the resulting image.

  3. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  4. Balancing work, study and home: a research with master’s students in a Brazilian University / Equilibrando trabalho, estudo e lar: um estudo com mestrandos em uma universidade brasileira

    Directory of Open Access Journals (Sweden)

    Amanda Magri Eller

    2016-06-01

    Full Text Available Purpose: Understand the tactics that nontraditional students use to manage the boundaries between work, home and study. Originality/gap/relevance/implications: The originality of this study relies on transfer of the focus from the conflict to the balance between work, home and study. It also breaks new ground by directing attention to the micro level of individual action, in contrast to a literature that traditionally studied organizational actions. Finally, it performs an innovative reading of the interface between work, home and study domains from the perspective of the boundary theory. Key methodological aspects: This qualitative study was held from 18 interviews that were recorded, transcribed and content analyzed, which revealed a list of individual tactics employed by respondents to reconcile the demands of work, home and study. Summary of key results: The analysis allowed us to identify 18 tactics that our respondents employ to negotiate the level of permeability between the boundaries between work, school and home. These tactics were classified as behavioral, communicative, physical and temporal. Key considerations/conclusions: The study revealed that students develop an active role by interpreting the expectations of the social actors from the home and work domains and from the institution where they study and adopt boundaries with degrees of permeability that enable a state of greater balance between these domains Objetivo: Compreender as táticas que estudantes não tradicionais utilizam para gerenciar as fronteiras entre trabalho, lar e estudo. Originalidade/Lacuna/Relevância/Implicações: O estudo se mostra original ao transferir o foco do conflito para o equilíbrio entre trabalho, lar e estudos. Além disso, também inova ao direcionar a atenção para o nível micro da ação individual, contrastando com uma literatura que tradicionalmente estuda ações organizacionais. Por fim, realiza uma leitura inovadora do fenômeno da

  5. Auscultation of concrete hydraulic dams by sonic tomography; Auscultation des structures hydrauliques en beton par tomographie sonique

    Energy Technology Data Exchange (ETDEWEB)

    Kharrat, Y.; Rhazi, J.; Ballivy, G. [Sherbrooke Univ., PQ (Canada). Dept. de Genie Civil; Cote, P. [Centre de Nantes, Bouguenais (France)

    1995-12-31

    Sonic tomography, a new nondestructive testing method, was described to document the aging and internal degradation of concrete structures. The method is based on the transmission of sonic waves through concrete structures. New tomographic methodology similar to that used in medical or geophysical imaging was applied to existing sonic auscultation techniques used in civil engineering. In the process the speed of propagation of sonic waves in structures is measured with arrays of detectors. Fissures or zones of degradation can be spatially localized and an internal image of the structure can be constructed. Case studies of two hydraulic dams, one from France, the other in Quebec were presented as illustrations. . The theory and experimental procedures involved were described. 16 refs., 1 tab., 12 figs.

  6. A fast sparse reconstruction algorithm for electrical tomography

    International Nuclear Information System (INIS)

    Zhao, Jia; Xu, Yanbin; Tan, Chao; Dong, Feng

    2014-01-01

    Electrical tomography (ET) has been widely investigated due to its advantages of being non-radiative, low-cost and high-speed. However, the image reconstruction of ET is a nonlinear and ill-posed inverse problem and the imaging results are easily affected by measurement noise. A sparse reconstruction algorithm based on L 1 regularization is robust to noise and consequently provides a high quality of reconstructed images. In this paper, a sparse reconstruction by separable approximation algorithm (SpaRSA) is extended to solve the ET inverse problem. The algorithm is competitive with the fastest state-of-the-art algorithms in solving the standard L 2 −L 1 problem. However, it is computationally expensive when the dimension of the matrix is large. To further improve the calculation speed of solving inverse problems, a projection method based on the Krylov subspace is employed and combined with the SpaRSA algorithm. The proposed algorithm is tested with image reconstruction of electrical resistance tomography (ERT). Both simulation and experimental results demonstrate that the proposed method can reduce the computational time and improve the noise robustness for the image reconstruction. (paper)

  7. Experimental study of water flow in nuclear fuel elements; Estudo experimental do escoamento de agua em elementos combustiveis nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Lorena Escriche, E-mail: ler@cdtn.br [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET), Belo Horizonte, MG (Brazil); Rezende, Hugo Cesar; Mattos, Joao Roberto Loureiro de; Barros Filho, Jose Afonso; Santos, Andre Augusto Campagnole dos, E-mail: hcr@cdtn.br, E-mail: jrmattos@cdtn.br, E-mail: jabf@cdtn.br, E-mail: aacs@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    This work aims to develop an experimental methodology for investigating the water flow through rod bundles after spacer grids of nuclear fuel elements of PWR type reactors. Speed profiles, with the device LDV (Laser Doppler Velocimetry), and the pressure drop between two sockets located before and after the spacer grid, using pressure transducers were measured.

  8. [Comparative assessment of MR-semiotics of acutest intracerebral hematomas in low- and extra high-field frequency magnetic resonance tomography].

    Science.gov (United States)

    Skvortsova, V I; Burenchev, D V; Tvorogova, T V; Guseva, O I; Prokhorov, A V; Smirnov, A M; Kupriianov, D A; Pirogov, Iu A

    2009-01-01

    An objective of the study was to compare sensitivity of low- and extra high-field frequency magnetic resonance (MR) tomography of acutest intracerebral hematomas (ICH) and to assess differences between symptoms in obtained images. A study was conducted using experimental ICH in rats (n=6). Hematomas were formed by two injections of autologic blood into the brain. MR-devices "Bio Spec 70/30" with magnetic field strength of 7 T and "Ellipse-150" with magnetic field strength of 0,15 T were used in the study. MR-tomography was carried out 3-5 h after the injections. Both MR-devices revealed the presence of pathological lesion in all animals. Extra highfield frequency MR-tomography showed the specific signs of ICH caused by the paramagnetic effect of deoxyhemoglobin in T2 and T2*-weighted images (WI) and low frequency MR-tomography - in T2*-WI only. The comparable sensitivity of low- and extra high-field frequency MR-devices in acutest ICH was established.

  9. O n-butil cianoacrilato na lobectomia pulmonar parcial em felinos: estudo experimental The n-butyl cyanoacrilate in partial lung lobectomy in cats: experimental study

    Directory of Open Access Journals (Sweden)

    Marcos Makoto Ishizaki

    2005-02-01

    Full Text Available O presente estudo teve como objetivo verificar a viabilidade do n-butil cianoacrilato na pneumostasia e hemostasia em lobectomia pulmonar parcial. Foram utilizadas seis gatas hígidas, adultas, com peso médio de três quilogramas. O procedimento cirúrgico consistiu na realização de toracotomia intercostal com lobectomia pulmonar parcial em que se utilizou adesivo cirúrgico para fechamento do lobo pulmonar. Após 21 dias da cirurgia, os animais foram novamente submetidos à toracotomia para a coleta de fragmento da região onde o adesivo fora aplicado, para análise histopatológica. Foram realizadas radiografias de tórax das pacientes para o acompanhamento pré e pós lobectomia pulmonar parcial e, aos dois, sete, 14 e 21 dias subseqüentes. As alterações radiográficas e clínicas encontradas como pneumotórax residual, aumento na densidade pulmonar, enfisema subcutâneo e apatia foram corrigidas em tempo hábil, não comprometendo os resultados do estudo. A histopatologia evidenciou reação inflamatória com predomínio de células mononucleares, neovascularização, proliferação de tecido conjuntivo e pequenas áreas de enfisema e atelectasia, sem comprometimento clínico significativo. Concluiu-se que o cianoacrilato é capaz de produzir adequada pneumostasia e hemostasia, e poderá ser uma opção para a realização de lobectomia pulmonar parcial em felinos.The n-butyl cyanoacrilate tissue adhesive was used in this study aiming to verify the viability of its use for hemostasis and to avoid air leakage in partial lung lobectomy. Six healthy adult female domestic shorthair cats, weight range of three kg were submitted to an intercostal thoracotomy with partial lung lobectomy using n-butyl cyanoacrilate to close the lobe. After 21 days they were submitted to another thoracotomy to collect a fragment of the lung where the adhesive was applied to a histopathological study. Chest films were taken pre and post partial lung lobectomy

  10. Auditoria interna de sistema de gestão ambiental: estudo de caso no Verdegreen Hotel

    OpenAIRE

    Adriano Lucena da Silva; Isaiane Vieira de Melo; Diego Rodrigues de Lucena

    2017-01-01

    Esta pesquisa analisa as contribuições e os desafios associados às auditorias internas no Verdegreen Hotel, empreendimento hoteleiro de grande destaque na cidade de João Pessoa-PB, selecionado como unidade de estudo por dispor de um Sistema de Gestão Ambiental (SGA) ISO 14001 implantado e certificado. Este estudo trata de uma pesquisa descritiva, baseada em um estudo de caso qualitativo. As técnicas utilizadas na metodologia foram: levantamento bibliográfico sobre as normas ISO que abordam as...

  11. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  12. Fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of residual intramuscular myxoma

    International Nuclear Information System (INIS)

    Zade, Anand; Ahire, Archana; Shetty, Shishir; Rai, Sujith; Bokka, Rajashekharrao; Velumani, Arokiaswamy; Kabnurkar, Rasika

    2015-01-01

    Intramuscular myxoma (IM) is a rare benign neoplasm. In a patient diagnosed with IM of left thigh, we report the utility of a postoperative fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography scan in assessing the efficacy of surgical excision

  13. Resistivity tomography-basic concepts and its application. Hiteiko tomography no kiso to oyo

    Energy Technology Data Exchange (ETDEWEB)

    Shima, H

    1990-12-31

    In this paper, principles and characteristics of resistivity tomography are outlined, and its application examples are described. Resistivity tomography is a technology to measure electric potential of many electrodes placed on the earth {prime} s surface or in the well and to analyze the resistivity distribution in the objective area. Arrangement of electrodes (current electrodes and potential electrodes) is determined taking account of the sensitivity distribution. Also, measurements need to be done not only between the surface and a borehole and between boreholes, but also along the wall of a borehole. After the measured data are corrected according to the influence of topography, the initial model is revised repeatedly with the Alpha Center method, and then, resistivity distribution maps are obtained. As an example of field application of resistivity tomography, a geological survey using three boreholes at the scheduled construction site for a dam is described. In this survey, distribution conditions of surface soil, gravel, and andesite were confirmed, and the results almost agreed with the results of seismic tomography. Moreover, another survey with resistivity tomography was carried out at the test site of hot dry rock power generation in Yamagata Prefecture. There, conductive solution was injected from the borehole after hydraulic fracturing, and cracking conditions of rocks were investigated. 28 refs., 21 figs., 1 tab.

  14. Discrete imaging models for three-dimensional optoacoustic tomography using radially symmetric expansion functions.

    Science.gov (United States)

    Wang, Kun; Schoonover, Robert W; Su, Richard; Oraevsky, Alexander; Anastasio, Mark A

    2014-05-01

    Optoacoustic tomography (OAT), also known as photoacoustic tomography, is an emerging computed biomedical imaging modality that exploits optical contrast and ultrasonic detection principles. Iterative image reconstruction algorithms that are based on discrete imaging models are actively being developed for OAT due to their ability to improve image quality by incorporating accurate models of the imaging physics, instrument response, and measurement noise. In this work, we investigate the use of discrete imaging models based on Kaiser-Bessel window functions for iterative image reconstruction in OAT. A closed-form expression for the pressure produced by a Kaiser-Bessel function is calculated, which facilitates accurate computation of the system matrix. Computer-simulation and experimental studies are employed to demonstrate the potential advantages of Kaiser-Bessel function-based iterative image reconstruction in OAT.

  15. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using (18) F-fluorodeoxyglucose positron emission tomography-computed tomography.

    Science.gov (United States)

    Kimizuka, Yoshifumi; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko; Hasegawa, Naoki

    2013-11-14

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess.

  16. Marketing do mercado de luxo: Estudo de caso Victoria's Secret

    Directory of Open Access Journals (Sweden)

    Ana Francisca Giuliani

    2013-12-01

    Full Text Available Este artigo teve por objetivo identificar quais são as estratégias de marketing utilizadas pela empresa varejista Victoria’s Secret para a fidelização do consumidor de luxo em nível global. O estudo caracterizou-se como uma pesquisa qualitativa, utilizando-se como estratégia de campo o estudo de caso de caráter ilustrativo. Para o alcance do objetivo proposto, dividiu-se o estudo em duas fases. Na primeira, denominada exploratória, buscou-se em dados secundários o embasamento para a construção do referencial teórico. Na segunda, adotou-se a técnica de pesquisa por observação, utilizando-se os sites da Victoria’s Secret, e analisou-se o composto de marketing aplicado ao mercado de luxo com base no modelo proposto por Nahás (2009. Concluiu-se que as estratégias da referida empresa se baseiam no luxo acessível, de modo que, além de conquistar o consumidor, a Victoria’s Secret consegue manter sua fidelidade por apresentar estratégias de forte apelo emocional.

  17. Application of reconstructive tomography to the measurement of density distribution in two-phase flow

    International Nuclear Information System (INIS)

    Fincke, J.R.; Berggren, M.J.; Johnson, S.A.

    1980-01-01

    The technique of reconstructive tomography has been applied to the measurement of average density and density distribution in multiphase flows. The technique of reconstructive tomography provides a model independent method of obtaining flow field density information. The unique features of interest in application of a practical tomographic densitometer system are the limited number of data values and the correspondingly coarse reconstruction grid (0.5 by 0.5 cm). These features were studied both experimentally, through the use of prototype hardware on a 3-in. pipe, and analytically, through computer generation of simulated data. Prototypical data were taken on phantoms constructed of Plexiglas and laminated Plexiglas, wood, and polyurethane foam. Reconstructions obtained from prototype data were compared with reconstructions from the simulated data

  18. Measuring Weld Profiles By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Noncontacting, nondestructive computer tomography system determines internal and external contours of welded objects. System makes it unnecessary to take metallurgical sections (destructive technique) or to take silicone impressions of hidden surfaces (technique that contaminates) to inspect them. Measurements of contours via tomography performed 10 times as fast as measurements via impression molds, and tomography does not contaminate inspected parts.

  19. Casos de Estudo em Estratégia e Marketing - Promovendo o Debate Empresarial

    OpenAIRE

    Au-Yong Oliveira, Manuel; Gonçalves, Ramiro; Martins, José; Moreira, Fernando; Branco, Frederico

    2016-01-01

    Os casos de estudo sobre organizações e empresas são um veículo de comunicação de excelência na área da gestão. Este livro reúne uma série de casos de estudo que abordam a inovação e a diferenciação, a internacionalização, o marketing, a evolução estratégica, os modelos de negócio (e como são afetados pela tecnologia), as aquisições de empresas, e tem ainda um caso de estudo sobre a responsabilidade social (área de crescente importância para todo o tipo de organizações). A estratégia e o mark...

  20. Casos de estudo em estratégia e marketing: promovendo o debate empresarial

    OpenAIRE

    Oliveira, Manuel Au-Yong; Gonçalves, Ramiro; Martins, José; Moreira, Fernando; Branco, Frederico

    2016-01-01

    Os casos de estudo sobre organizações e empresas são um veículo de comunicação de excelência na área da gestão. Este livro reúne uma série de casos de estudo que abordam a inovação e a diferenciação, a internacionalização, o marketing, a evolução estratégica, os modelos de negócio (e como são afetados pela tecnologia), as aquisições de empresas, e tem ainda um caso de estudo sobre a responsabilidade social (área de crescente importância para todo o tipo de organizações). A estratégia e o mark...

  1. Mobbing: assédio moral em contexto de enfermagem - estudo preliminar

    OpenAIRE

    Carvalho, Guilhermina

    2007-01-01

    A temática abordada neste estudo refere-se a um fenómeno que não é recente, contudo pouco estudado em Portugal: o Mobbing. Após uma pesquisa bibliográfica, verificou-se uma prevalência significativa de mobbing em contexto de trabalho em todo o mundo, nomeadamente na profissão de enfermagem. Este estudo pretende validar uma escala sobre as estratégias de mobbing: o LIPT - 60 (Leymann Inventory of Psychological Terrorization) a uma população portuguesa de enfermeiros, assim como, avaliar a ...

  2. Estilos educativos parentais, valores e autoconceito de adolescentes : um estudo transcultural

    OpenAIRE

    Iglesia, Yara Rodrigues de la

    2017-01-01

    Tese de doutoramento, Educação (Psicologia da Educação), Universidade de Lisboa, Instituto de Educação, 2017 O presente estudo teve como objetivo principal investigar, a partir de uma perspectiva transcultural, como se caracterizam os estilos educativos parentais, o autoconceito e os valores na adolescência, como se relacionam estas variáveis entre si e como se diferenciam, em função de variáveis específicas. Em relação à metodologia, foi realizado um estudo quantitativo, de tipo transvers...

  3. Positron emission tomography/computed tomography surveillance in patients with Hodgkin lymphoma in first remission has a low positive predictive value and high costs.

    Science.gov (United States)

    El-Galaly, Tarec Christoffer; Mylam, Karen Juul; Brown, Peter; Specht, Lena; Christiansen, Ilse; Munksgaard, Lars; Johnsen, Hans Erik; Loft, Annika; Bukh, Anne; Iyer, Victor; Nielsen, Anne Lerberg; Hutchings, Martin

    2012-06-01

    The value of performing post-therapy routine surveillance imaging in patients with Hodgkin lymphoma is controversial. This study evaluates the utility of positron emission tomography/computed tomography using 2-[18F]fluoro-2-deoxyglucose for this purpose and in situations with suspected lymphoma relapse. We conducted a multicenter retrospective study. Patients with newly diagnosed Hodgkin lymphoma achieving at least a partial remission on first-line therapy were eligible if they received positron emission tomography/computed tomography surveillance during follow-up. Two types of imaging surveillance were analyzed: "routine" when patients showed no signs of relapse at referral to positron emission tomography/computed tomography, and "clinically indicated" when recurrence was suspected. A total of 211 routine and 88 clinically indicated positron emission tomography/computed tomography studies were performed in 161 patients. In ten of 22 patients with recurrence of Hodgkin lymphoma, routine imaging surveillance was the primary tool for the diagnosis of the relapse. Extranodal disease, interim positron emission tomography-positive lesions and positron emission tomography activity at response evaluation were all associated with a positron emission tomography/computed tomography-diagnosed preclinical relapse. The true positive rates of routine and clinically indicated imaging were 5% and 13%, respectively (P = 0.02). The overall positive predictive value and negative predictive value of positron emission tomography/computed tomography were 28% and 100%, respectively. The estimated cost per routine imaging diagnosed relapse was US$ 50,778. Negative positron emission tomography/computed tomography reliably rules out a relapse. The high false positive rate is, however, an important limitation and a confirmatory biopsy is mandatory for the diagnosis of a relapse. With no proven survival benefit for patients with a pre-clinically diagnosed relapse, the high costs and low

  4. A sociologia funcionalista nos estudos organizacionais: foco em Durkheim

    Directory of Open Access Journals (Sweden)

    Augusto Cabral

    Full Text Available O tema que estrutura este ensaio é o da sociologia funcionalista, particularmente em termos de sua influência nos estudos organizacionais. O seu foco de análise é duplo. Em um primeiro momento, as obras de Durkheim. Em um segundo momento, o impacto e a supremacia dos enfoques funcionalistas nos estudos organizacionais. Embora seus segmentos estejam inter-relacionados, ele é composto de quatro partes. Na primeira, é feita uma análise histórica da emergência e sistematização das ciências sociais, de modo a traçar sua evolução até o surgimento dos trabalhos de Durkheim. Na segunda, tomando como referencial a obra de Burrell e Morgan (1979, é estudado o paradigma funcionalista em termos de sua origem e expoentes, com destaque para Comte e Spencer, visando chegar a uma compreensão inicial do pensamento de Durkheim e de sua sociologia. Na terceira, a vida e as principais obras de Durkheim são sumariadas e discutidas. Por fim, o status atual dos estudos organizacionais -vistos como um conjunto impreciso, elástico e eclético de teorias e pesquisas sociais voltados para os problemas das organizações -é analisado em termos de seus pressupostos epistemológicos e ontológicos subjacentes, como meio de explicitar a supremacia dos enfoques positivistas-funcionalistas.

  5. Diffuse nesidioblastosis diagnosed on a Ga-68 DOTATATE positron emission tomography/computerized tomography

    International Nuclear Information System (INIS)

    Arun, Sasikumar; Mittal, Bhagwant Rai; Shukla, Jaya; Bhattacharya, Anish; Kumar, Praveen

    2013-01-01

    The authors describe a 50 days old pre-term infant with persistent hyperinsulinemic hypoglycemia of infancy in whom 68 Ga DOTATATE positron emission tomography/computerized tomography scan showed diffusely increased tracer uptake in the entire pancreas with no abnormal tracer uptake anywhere else in the body, suggestive of a diffuse variant of nesidioblastosis. (author)

  6. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  7. Microwave tomography for functional imaging of extremity soft tissues: feasibility assessment

    International Nuclear Information System (INIS)

    Semenov, Serguei; Kellam, James; Althausen, Peter; Williams, Thomas; Abubakar, Aria; Bulyshev, Alexander; Sizov, Yuri

    2007-01-01

    It is important to assess the viability of extremity soft tissues, as this component is often the determinant of the final outcome of fracture treatment. Microwave tomography (MWT) and sensing might be able to provide a fast and mobile assessment of such properties. MWT imaging of extremities possesses a complicated, nonlinear, high dielectric contrast inverse problem of diffraction tomography. There is a high dielectric contrast between bone and soft tissue in the extremities. A contrast between soft tissue abnormalities is less pronounced when compared with the high bone-soft tissue contrast. The goal of this study was to assess the feasibility of MWT for functional imaging of extremity soft tissues, i.e. to detect a relatively small contrast within soft tissues in closer proximity to high contrast boney areas. Both experimental studies and computer simulation were performed. Experiments were conducted using live pigs with compromised blood flow and compartment syndrome within an extremity. A whole 2D tomographic imaging cycle at 1 GHz was computer simulated and images were reconstructed using the Newton, MR-CSI and modified Born methods. Results of experimental studies demonstrate that microwave technology is sensitive to changes in the soft tissue blood content and elevated compartment pressure. It was demonstrated that MWT is feasible for functional imaging of extremity soft tissues, circulatory-related changes, blood flow and elevated compartment pressure

  8. Batch Computed Tomography Analysis of Projectiles

    Science.gov (United States)

    2016-05-01

    ARL-TR-7681 ● MAY 2016 US Army Research Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt, Chris M...Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt and Matthew S Bratcher Weapons and Materials Research...values to account for projectile variability in the ballistic evaluation of armor. 15. SUBJECT TERMS computed tomography , CT, BS41, projectiles

  9. Modelização e estudo experimental de óxidos multiferróicos

    CERN Document Server

    Fenta, Abel

    The main goal of this work was the theoretical and experimental study of multiferroics oxides. This particular approach focused mainly on the ferroelectric material barium titanate. The essence of this theoretical study is the ab initio calculation of hiperfine parameters using the Wien2k software. This software, which uses the selfconsistent $LAPW$ method to solve the Kohn-Sham equations, allowed to determine the electric field gradient and the BaTiO$_3$ system’s total energy in its different structural phases, and study its behaviour in function of the different lattice parameters. The modeling of stratified systems of the (XTiO$_3$).(BaTiO$_3$)$_{n-1}$ and (BaZO$_3$).(BaTiO$_3$ )$_{n-1}$, with X=Cd and Hg and Z=Fe, from n=2 to n=6 type, built from the experimental latice parameters (formula) in the tetragonal sage was also made. This simulation can be related to the physical situation of the epitaxial growth of XTiO$_3$ a layer on n BaTiO$_3$ layers. It was also studied the effect of the Cd ion volume di...

  10. Computational optical tomography using 3-D deep convolutional neural networks

    Science.gov (United States)

    Nguyen, Thanh; Bui, Vy; Nehmetallah, George

    2018-04-01

    Deep convolutional neural networks (DCNNs) offer a promising performance for many image processing areas, such as super-resolution, deconvolution, image classification, denoising, and segmentation, with outstanding results. Here, we develop for the first time, to our knowledge, a method to perform 3-D computational optical tomography using 3-D DCNN. A simulated 3-D phantom dataset was first constructed and converted to a dataset of phase objects imaged on a spatial light modulator. For each phase image in the dataset, the corresponding diffracted intensity image was experimentally recorded on a CCD. We then experimentally demonstrate the ability of the developed 3-D DCNN algorithm to solve the inverse problem by reconstructing the 3-D index of refraction distributions of test phantoms from the dataset from their corresponding diffraction patterns.

  11. Kinetic modeling in pre-clinical positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kuntner, Claudia [AIT Austrian Institute of Technology GmbH, Seibersdorf (Austria). Biomedical Systems, Health and Environment Dept.

    2014-07-01

    Pre-clinical positron emission tomography (PET) has evolved in the last few years from pure visualization of radiotracer uptake and distribution towards quantification of the physiological parameters. For reliable and reproducible quantification the kinetic modeling methods used to obtain relevant parameters of radiotracer tissue interaction are important. Here we present different kinetic modeling techniques with a focus on compartmental models including plasma input models and reference tissue input models. The experimental challenges of deriving the plasma input function in rodents and the effect of anesthesia are discussed. Finally, in vivo application of kinetic modeling in various areas of pre-clinical research is presented and compared to human data.

  12. Excitation-resolved cone-beam x-ray luminescence tomography.

    Science.gov (United States)

    Liu, Xin; Liao, Qimei; Wang, Hongkai; Yan, Zhuangzhi

    2015-07-01

    Cone-beam x-ray luminescence computed tomography (CB-XLCT), as an emerging imaging technique, plays an important role in in vivo small animal imaging studies. However, CB-XLCT suffers from low-spatial resolution due to the ill-posed nature of reconstruction. We improve the imaging performance of CB-XLCT by using a multiband excitation-resolved imaging scheme combined with principal component analysis. To evaluate the performance of the proposed method, the physical phantom experiment is performed with a custom-made XLCT/XCT imaging system. The experimental results validate the feasibility of the method, where two adjacent nanophosphors (with an edge-to-edge distance of 2.4 mm) can be located.

  13. Computed tomography of pulmonary nodules

    International Nuclear Information System (INIS)

    Nakata, Hajime; Honda, Hiroshi; Nakayama, Chikashi; Kimoto, Tatsuya; Nakayama, Takashi

    1983-01-01

    We have evaluated the value of computed tomography (CT) in distinguishing benign and malignant pulmonary nodules. CT was performed on 30 cases of solitary pulmonary nodules consisting of 17 primary lung cancers, 3 metastatic tumors and 10 benign nodules. The CT number was calculated for each lesion. Three benign nodules showed CT numbers well above the range of malignant nodules, and only in one of them was calcification visible on conventional tomography. In 6 benign nodules, the CT numbers overlapped those of malignant lesion and could not be differentiated. Thus the measurement of CT number can be useful to confirm the benign nature of certain nodules when calcification is unclear or not visible on conventional tomography. As for the morphological observation of the nodule, CT was not superior to conventional tomography and its value seems to be limited. (author)

  14. Three dimensional mapping of Fe dopants in ceria nanocrystals using direct spectroscopic electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Goris, Bart; Meledina, Maria; Turner, Stuart [EMAT, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp (Belgium); Zhong, Zhichao [Centrum Wiskunde & Informatica, P.O. Box 94079, 1090 GB Amsterdam (Netherlands); Batenburg, K. Joost [Centrum Wiskunde & Informatica, P.O. Box 94079, 1090 GB Amsterdam (Netherlands); Mathematical Institute, Leiden University, Niels Bohrweg 1, 2333CA Leiden (Netherlands); Bals, Sara [EMAT, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp (Belgium)

    2016-12-15

    Electron tomography is a powerful technique for the 3D characterization of the morphology of nanostructures. Nevertheless, resolving the chemical composition of complex nanostructures in 3D remains challenging and the number of studies in which electron energy loss spectroscopy (EELS) is combined with tomography is limited. During the last decade, dedicated reconstruction algorithms have been developed for HAADF-STEM tomography using prior knowledge about the investigated sample. Here, we will use the prior knowledge that the experimental spectrum of each reconstructed voxel is a linear combination of a well-known set of references spectra in a so-called direct spectroscopic tomography technique. Based on a simulation experiment, it is shown that this technique provides superior results in comparison to conventional reconstruction methods for spectroscopic data, especially for spectrum images containing a relatively low signal to noise ratio. Next, this technique is used to investigate the spatial distribution of Fe dopants in Fe:Ceria nanoparticles in 3D. It is shown that the presence of the Fe{sup 2+} dopants is correlated with a reduction of the Ce atoms from Ce{sup 4+} towards Ce{sup 3+}. In addition, it is demonstrated that most of the Fe dopants are located near the voids inside the nanoparticle. - Highlights: • A direct tomographic reconstruction technique is proposed for spectroscopic data. • Spectrum fitting is combined with a tomography reconstruction in a single step. • The technique yields superior results for data with a low signal to noise ratio. • The technique is applied to map Fe dopants in ceria nanoparticles.

  15. Hybrid Single Photon Emission Computed Tomography/Computed Tomography Sulphur Colloid Scintigraphy in Focal Nodular Hyperplasia

    International Nuclear Information System (INIS)

    Bhoil, Amit; Gayana, Shankramurthy; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2013-01-01

    It is important to differentiate focal nodular hyperplasia (FNH), a benign condition of liver most commonly affecting women, from other neoplasm such as hepatic adenoma and metastasis. The functional reticuloendothelial features of FNH can be demonstrated by scintigraphy. We present a case of breast cancer in whom fluorodeoxyglucose positron emission tomography/computerized tomography (CT) showed a homogenous hyperdense lesion in liver, which on Tc99m sulfur colloid single-photon emission computed tomography/CT was found to have increased focal tracer uptake suggestive of FNH

  16. NECTAR-A fission neutron radiography and tomography facility

    International Nuclear Information System (INIS)

    Buecherl, T.; Lierse von Gostomski, Ch.; Breitkreutz, H.; Jungwirth, M.; Wagner, F.M.

    2011-01-01

    NECTAR (Neutron Computerized Tomography and Radiography) is a versatile facility for radiographic and tomographic investigations as well as for neutron activation experiments using fission neutrons. The radiation sources for this facility are two plates of highly enriched uranium situated in the moderator vessel in FRM II. Thermal neutrons originating from the main fuel element of the reactor generate in these plates fast neutrons. These can escape through a horizontal beam tube without moderation. The beam can be filtered and manipulated in order to reduce the accompanying gamma radiation and to match the specific experimental tasks. A summary of the main parameters required for experimental set-up and (quantitative) data evaluation is presented. The (measured) spectra of the neutron and gamma radiations are shown along with the effect of different filters on their behavior. The neutron and gamma fluxes, dose rates, L/D-ratios, etc. and the main parameters of the actually used detection systems for neutron imaging are given, too.

  17. NECTAR-A fission neutron radiography and tomography facility

    Energy Technology Data Exchange (ETDEWEB)

    Buecherl, T., E-mail: thomas.buecherl@radiochemie.de [Technische Universitaet Muenchen, Lehrstuhl fuer Radiochemie (RCM), Walther-Meissner-Str. 3, 85748 Garching (Germany); Lierse von Gostomski, Ch. [Technische Universitaet Muenchen, Lehrstuhl fuer Radiochemie (RCM), Walther-Meissner-Str. 3, 85748 Garching (Germany); Breitkreutz, H.; Jungwirth, M.; Wagner, F.M. [Technische Universitaet Muenchen, Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II) (Germany)

    2011-09-21

    NECTAR (Neutron Computerized Tomography and Radiography) is a versatile facility for radiographic and tomographic investigations as well as for neutron activation experiments using fission neutrons. The radiation sources for this facility are two plates of highly enriched uranium situated in the moderator vessel in FRM II. Thermal neutrons originating from the main fuel element of the reactor generate in these plates fast neutrons. These can escape through a horizontal beam tube without moderation. The beam can be filtered and manipulated in order to reduce the accompanying gamma radiation and to match the specific experimental tasks. A summary of the main parameters required for experimental set-up and (quantitative) data evaluation is presented. The (measured) spectra of the neutron and gamma radiations are shown along with the effect of different filters on their behavior. The neutron and gamma fluxes, dose rates, L/D-ratios, etc. and the main parameters of the actually used detection systems for neutron imaging are given, too.

  18. NECTAR—A fission neutron radiography and tomography facility

    Science.gov (United States)

    Bücherl, T.; Lierse von Gostomski, Ch.; Breitkreutz, H.; Jungwirth, M.; Wagner, F. M.

    2011-09-01

    NECTAR (Neutron Computerized Tomography and Radiography) is a versatile facility for radiographic and tomographic investigations as well as for neutron activation experiments using fission neutrons. The radiation sources for this facility are two plates of highly enriched uranium situated in the moderator vessel in FRM II. Thermal neutrons originating from the main fuel element of the reactor generate in these plates fast neutrons. These can escape through a horizontal beam tube without moderation. The beam can be filtered and manipulated in order to reduce the accompanying gamma radiation and to match the specific experimental tasks. A summary of the main parameters required for experimental set-up and (quantitative) data evaluation is presented. The (measured) spectra of the neutron and gamma radiations are shown along with the effect of different filters on their behavior. The neutron and gamma fluxes, dose rates, L/ D-ratios, etc. and the main parameters of the actually used detection systems for neutron imaging are given, too.

  19. Research on Image Reconstruction Algorithms for Tuber Electrical Resistance Tomography System

    Directory of Open Access Journals (Sweden)

    Jiang Zili

    2016-01-01

    Full Text Available The application of electrical resistance tomography (ERT technology has been expanded to the field of agriculture, and the concept of TERT (Tuber Electrical Resistance Tomography is proposed. On the basis of the research on the forward and the inverse problems of the TERT system, a hybrid algorithm based on genetic algorithm is proposed, which can be used in TERT system to monitor the growth status of the plant tubers. The image reconstruction of TERT system is different from the conventional ERT system for two phase-flow measurement. Imaging of TERT needs more precision measurement and the conventional ERT cares more about the image reconstruction speed. A variety of algorithms are analyzed and optimized for the purpose of making them suitable for TERT system. For example: linear back projection, modified Newton-Raphson and genetic algorithm. Experimental results showed that the novel hybrid algorithm is superior to other algorithm and it can effectively improve the image reconstruction quality.

  20. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  1. A STUDY OF ROOT CANAL MORPHOLOGY OF Cebus apella TEETH ESTUDO ANATÔMICO DO CANAL RADICULAR DE DENTES DE Cebus apella

    OpenAIRE

    Priscilla Rocha Afonso; Leila Marques Araújo; Rafael Rodrigues Lima; Suely Maria Lamarão

    2008-01-01

    Realizou-se um estudo anatômico em dentes do Cebus apella, para análise da anatomia interna do canal radicular dessa espécie, normatizando seu uso como modelo experimental. Utilizaram-se doze animais adultos. Após a remoção do tecido orgânico, os dentes foram removidos, seccionados e fotografados, sendo analisados com um estereomicroscópio. Os resultados mostraram que os dentes apresentaram características semelhantes às dos seres humanos, mas com algumas peculiaridades, tais como: a anatomia...

  2. O estudo das fontes estrangeiras na obra de Machado de Assis e o caso italiano

    Directory of Open Access Journals (Sweden)

    Eugênio Vinci de Moraes

    2008-04-01

    Full Text Available Os estudos das fontes italianas na obra de Machado de Assis ainda são uma esquecida árvore no meio da floresta dos estudos machadianos. Três aspectos explicam talvez a posição marginal dessas pesquisas: primeiro, o número menor de refer~encias italianas perante as inglesas e francesas, por exemplo; segundo, a ausência de estudos de maior fôlego; por último, por essa fonte não tocar nas questões centrais da obra de Machado. Neste artigo pretende-se mostrar de que forma trabalhar com as fontes em Machado, com base em três modelos de análise, e também de que forma esses estudos podem tocar, sim, em pontos fundamentais da obra de Machado, desde que não se desdenhe a já alentada e qualificada fortuna crítica do escritor fluminense.

  3. UTILIZAÇÃO DE BANCADAS DE ENSAIO PARA ESTUDO DO COMPORTAMENTO DINÂMICO DE MÁQUINAS ROTATIVAS - VIBRAÇÕES MECÂNICAS -

    OpenAIRE

    Cavalcante, Paula Francinetti; Jesus, Solival Santana

    2011-01-01

    As máquinas rotativas são equipamentos utilizados nos diversos ambientes do cotidiano, tornando-se elementos indispensáveis nas atividades humanas. Devido ao alto nível de exigência em tais especialidades, conhecer o comportamento dinâmico dessas máquinas é fundamental. Como estudo de caso neste trabalho foi feito a análise experimental para um conjunto suportado por 2 mancais de deslizamento, localizado na Refinaria Landulpho Alves (RLAM) – PETROBRAS, e em seguida, foi analisado a resposta...

  4. Using x-ray computed tomography in hydrology: Systems, resolutions, and limitations

    DEFF Research Database (Denmark)

    Wildenschild, Dorthe; Hopmans, J.W.; Vaz, C.M.P.

    2002-01-01

    media, obtained with different scanning systems and sample sizes, to illustrate advantages and limitations of these various systems, including topics of spatial resolution and contrast. In addition, we present examples of our most recent three-dimensional high-resolution images, for which......A combination of advances in experimental techniques and mathematical analysis has made it possible to characterize phase distribution and pore geometry in porous media using non-destructive X-ray computed tomography (CT). We present qualitative and quantitative CT results for partially saturated...

  5. Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Mogensen, Mette; Themstrup, Lotte; Banzhaf, Christina

    2014-01-01

    Optical coherence tomography (OCT) has developed rapidly since its first realisation in medicine and is currently an emerging technology in the diagnosis of skin disease. OCT is an interferometric technique that detects reflected and backscattered light from tissue and is often described as the o......Optical coherence tomography (OCT) has developed rapidly since its first realisation in medicine and is currently an emerging technology in the diagnosis of skin disease. OCT is an interferometric technique that detects reflected and backscattered light from tissue and is often described...

  6. X-ray Compton line scan tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kupsch, Andreas; Lange, Axel; Jaenisch, Gerd-Ruediger [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany). Fachgruppe 8.5 - Mikro-ZfP; Hentschel, Manfred P. [Technische Univ. Berlin (Germany); Kardjilov, Nikolay; Markoetter, Henning; Hilger, Andre; Manke, Ingo [Helmholtz-Zentrum Berlin (HZB) (Germany); Toetzke, Christian [Potsdam Univ. (Germany)

    2015-07-01

    The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.

  7. 18 F-fluorodeoxyglucose positron emission tomography-computed tomography for preoperative lymph node staging in patients undergoing radical cystectomy for bladder cancer: a prospective study.

    Science.gov (United States)

    Hitier-Berthault, Maryam; Ansquer, Catherine; Branchereau, Julien; Renaudin, Karine; Bodere, Françoise; Bouchot, Olivier; Rigaud, Jérôme

    2013-08-01

    The objective of our study was to analyze the diagnostic performance of (18) F-fluorodeoxyglucose positron emission tomography-computed tomography for lymph node staging in patients with bladder cancer before radical cystectomy and to compare it with that of computed tomography. A total of 52 patients operated on between 2005 and 2010 were prospectively included in this prospective, mono-institutional, open, non-randomized pilot study. Patients who had received neoadjuvant chemotherapy or radiotherapy were excluded. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography in addition to computed tomography was carried out for lymph node staging of bladder cancer before radical cystectomy. Lymph node dissection during radical cystectomy was carried out. Findings from (18) F-fluorodeoxyglucose positron emission tomography-computed tomography and computed tomography were compared with the results of definitive histological examination of the lymph node dissection. The diagnostic performance of the two imaging modalities was assessed and compared. The mean number of lymph nodes removed during lymph node dissection was 16.5 ± 10.9. Lymph node metastasis was confirmed on histological examination in 22 cases (42.3%). This had been suspected in five cases (9.6%) on computed tomography and in 12 cases (23.1%) on (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. Sensitivity, specificity, positive predictive value, negative predictive value, relative risk and accuracy were 9.1%, 90%, 40%, 57.4%, 0.91 and 55.7%, respectively, for computed tomography, and 36.4%, 86.7%, 66.7%, 65%, 2.72, 65.4%, respectively, for (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography is more reliable than computed tomography for preoperative lymph node staging in patients with invasive bladder carcinoma undergoing radical cystectomy. © 2012 The Japanese

  8. Coleta Seletiva – Um estudo comparativo em contextos turísticos

    OpenAIRE

    Silva, Ana Flávia da

    2015-01-01

    Anais do IV Encontro de Iniciação Científica da Unila - “UNILA 5 anos: Integração em Ciência, Tecnologia e Cultura na Tríplice Fronteira” - 05 e 06 de novembro de 2015 – Sessão Ciência Política, Sociologia, Filosofia e Antropologia O projeto Coleta Seletiva- um estudo comparativo, traz um debate sobre a eficácia da coleta seletiva em Foz. Propõe, principalmente realizar um estudo etnográfico na cidade de Foz do Iguaçu, com a intenção de identificar aspectos do trabalho na reciclagem ...

  9. In vivo multiphoton tomography and fluorescence lifetime imaging of human brain tumor tissue.

    Science.gov (United States)

    Kantelhardt, Sven R; Kalasauskas, Darius; König, Karsten; Kim, Ella; Weinigel, Martin; Uchugonova, Aisada; Giese, Alf

    2016-05-01

    High resolution multiphoton tomography and fluorescence lifetime imaging differentiates glioma from adjacent brain in native tissue samples ex vivo. Presently, multiphoton tomography is applied in clinical dermatology and experimentally. We here present the first application of multiphoton and fluorescence lifetime imaging for in vivo imaging on humans during a neurosurgical procedure. We used a MPTflex™ Multiphoton Laser Tomograph (JenLab, Germany). We examined cultured glioma cells in an orthotopic mouse tumor model and native human tissue samples. Finally the multiphoton tomograph was applied to provide optical biopsies during resection of a clinical case of glioblastoma. All tissues imaged by multiphoton tomography were sampled and processed for conventional histopathology. The multiphoton tomograph allowed fluorescence intensity- and fluorescence lifetime imaging with submicron spatial resolution and 200 picosecond temporal resolution. Morphological fluorescence intensity imaging and fluorescence lifetime imaging of tumor-bearing mouse brains and native human tissue samples clearly differentiated tumor and adjacent brain tissue. Intraoperative imaging was found to be technically feasible. Intraoperative image quality was comparable to ex vivo examinations. To our knowledge we here present the first intraoperative application of high resolution multiphoton tomography and fluorescence lifetime imaging of human brain tumors in situ. It allowed in vivo identification and determination of cell density of tumor tissue on a cellular and subcellular level within seconds. The technology shows the potential of rapid intraoperative identification of native glioma tissue without need for tissue processing or staining.

  10. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  11. The value of computed tomography in ''sciatica''

    International Nuclear Information System (INIS)

    Boehm-Jurkovic, H.; Hammer, B.

    1981-01-01

    13 cases of therapy-resistant lumboischialgia without herniated disk, caused in 12 cases by a tumour and in 1 case by an abscess, were examined by computed tomography of the lumbar and pelvic region. This method is indicated immediately after insufficient results of conventional X-ray methods (including tomography) and of lumbosacral radiculography. The computed tomography is indispensable also in patients with ''sciatica'' with a known malignoma. The information given by computed tomography is essential for the therapy planning. (author)

  12. Noninvasive imaging of experimental lung fibrosis.

    Science.gov (United States)

    Zhou, Yong; Chen, Huaping; Ambalavanan, Namasivayam; Liu, Gang; Antony, Veena B; Ding, Qiang; Nath, Hrudaya; Eary, Janet F; Thannickal, Victor J

    2015-07-01

    Small animal models of lung fibrosis are essential for unraveling the molecular mechanisms underlying human fibrotic lung diseases; additionally, they are useful for preclinical testing of candidate antifibrotic agents. The current end-point measures of experimental lung fibrosis involve labor-intensive histological and biochemical analyses. These measures fail to account for dynamic changes in the disease process in individual animals and are limited by the need for large numbers of animals for longitudinal studies. The emergence of noninvasive imaging technologies provides exciting opportunities to image lung fibrosis in live animals as often as needed and to longitudinally track the efficacy of novel antifibrotic compounds. Data obtained by noninvasive imaging provide complementary information to histological and biochemical measurements. In addition, the use of noninvasive imaging in animal studies reduces animal usage, thus satisfying animal welfare concerns. In this article, we review these new imaging modalities with the potential for evaluation of lung fibrosis in small animal models. Such techniques include micro-computed tomography (micro-CT), magnetic resonance imaging, positron emission tomography (PET), single photon emission computed tomography (SPECT), and multimodal imaging systems including PET/CT and SPECT/CT. It is anticipated that noninvasive imaging will be increasingly used in animal models of fibrosis to gain insights into disease pathogenesis and as preclinical tools to assess drug efficacy.

  13. A revista Saúde em Debate como fonte e objeto de estudo

    Directory of Open Access Journals (Sweden)

    Daniela Carvalho Sophia

    2013-11-01

    Full Text Available A presente nota de pesquisa busca divulgar estudo sobre o Centro Brasileiro de Estudos da Saúde e o movimento de reforma sanitária desenvolvido no âmbito do Programa de História das Ciências e da Saúde Pública da Casa de Oswaldo Cruz. Atém-se à revista Saúde em Debate , periódico do Centro, devido à relevância que teve na área ao longo dos dez anos de publicação. A utilização da revista na pesquisa deu visibilidade a questões pertinentes à participação de seus membros na reforma sanitária. Enfatiza-se o fato de que a utilização do periódico como fonte e objeto de estudo para fomentar a produção de pesquisa na área da saúde merece investigação mais ampla.

  14. Unidade de estudos de mastites em pequenos ruminantes: estudos em ovinos de regime extensivo Small ruminant mastitis unity: studies on grazing ewes

    Directory of Open Access Journals (Sweden)

    M.C. Queiroga

    2007-01-01

    Full Text Available A “Unidade de Estudo de Mastites em Pequenos Ruminantes”, formalmente constituída no âmbito do Programa Nacional de Re-equipamento Científico, da Fundação para a Ciência e a Tecnologia, vem dar corpo ao trabalho de colaboração de diversas equipas de investigação que se têm debruçado sobre a problemática das infecções intramamárias em pequenos ruminantes, nos seus aspectos de saúde animal, saúde pública veterinária e qualidade e segurança alimentar. Tem como principal objectivo criar condições para o desenvolvimento de trabalhos de investigação e divulgação científica que contribuam para reduzir a prevalência de mastites em pequenos ruminantes e assim melhorar a produção e a qualidade do leite, favorecendo produtores de leite, produtores de queijo e consumidores. Entre os trabalhos já realizados pela equipa científica, destacam-se o isolamento e identificação de agentes etiológicos de mastite em ovelhas, o estudo de factores de virulência nas bactérias mais relevantes, o estudo dos mecanismos de infecção e a resposta imunológica local e sistémica do hospedeiro e outros estudos na área da epidemiologia. O estudo da etiologia e da fisiopatologia da mastite ovina, com o objectivo de compreender a modulação da resposta imunitária da glândula mamária, poderá contribuir para o desenvolvimento de métodos de controlo com base na estimulação da resposta imunitária, alternativos ao uso de antibióticos.The “Small Ruminant Mastitis Unit”, formally constituted in the scope of the Programa Nacional de Re-equipamento Científico, Science and Technology Foundation, gathers the collaborative work of several research groups that have been addressing the issue of small ruminants intramammary infections, related to animal health, veterinary public health and food safety and quality. Its main purpose is to generate an adequate environment for research and scientific communication that may contribute to

  15. Guided wave tomography in anisotropic media using recursive extrapolation operators

    Science.gov (United States)

    Volker, Arno

    2018-04-01

    Guided wave tomography is an advanced technology for quantitative wall thickness mapping to image wall loss due to corrosion or erosion. An inversion approach is used to match the measured phase (time) at a specific frequency to a model. The accuracy of the model determines the sizing accuracy. Particularly for seam welded pipes there is a measurable amount of anisotropy. Moreover, for small defects a ray-tracing based modelling approach is no longer accurate. Both issues are solved by applying a recursive wave field extrapolation operator assuming vertical transverse anisotropy. The inversion scheme is extended by not only estimating the wall loss profile but also the anisotropy, local material changes and transducer ring alignment errors. This makes the approach more robust. The approach will be demonstrated experimentally on different defect sizes, and a comparison will be made between this new approach and an isotropic ray-tracing approach. An example is given in Fig. 1 for a 75 mm wide, 5 mm deep defect. The wave field extrapolation based tomography clearly provides superior results.

  16. Use of Computed Tomography and Positron Emission Tomography/Computed Tomography for Staging of Local Extent in Patients With Malignant Pleural Mesothelioma

    OpenAIRE

    Frauenfelder, Thomas; Kestenholz, Peter; Hunziker, Roger; Nguyen, Thi Dan Linh; Fries, Martina; Veit-Haibach, Patrick; Husmann, Lars; Stahel, Rolf; Weder, Walter; Opitz, Isabelle

    2015-01-01

    PURPOSE The objective of this study was to determine the diagnostic value of computed tomography (CT) and positron emission tomography (PET)/CT for staging of malignant pleural mesothelioma (MPM) in patients undergoing induction chemotherapy. METHODS Sixty-two patients (median age, 61 years; female: n = 9) with proven MPM underwent CT after induction chemotherapy. Of these, 28 underwent additional PET/CT. Extrapleural pneumonectomy was performed for pathological TNM staging. Clinical TNM s...

  17. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  18. Representation of photon limited data in emission tomography using origin ensembles

    Energy Technology Data Exchange (ETDEWEB)

    Sitek, A [Radiology Department, Brigham and Women' s Hospital and Harvard Medical School, 75 Francis Street, Boston, MA 02115 (United States)], E-mail: asitek@bwh.harvard.edu

    2008-06-21

    Representation and reconstruction of data obtained by emission tomography scanners are challenging due to high noise levels in the data. Typically, images obtained using tomographic measurements are represented using grids. In this work, we define images as sets of origins of events detected during tomographic measurements; we call these origin ensembles (OEs). A state in the ensemble is characterized by a vector of 3N parameters Y, where the parameters are the coordinates of origins of detected events in a three-dimensional space and N is the number of detected events. The 3N-dimensional probability density function (PDF) for that ensemble is derived, and we present an algorithm for OE image estimation from tomographic measurements. A displayable image (e.g. grid based image) is derived from the OE formulation by calculating ensemble expectations based on the PDF using the Markov chain Monte Carlo method. The approach was applied to computer-simulated 3D list-mode positron emission tomography data. The reconstruction errors for a 10 000 000 event acquisition for simulated ranged from 0.1 to 34.8%, depending on object size and sampling density. The method was also applied to experimental data and the results of the OE method were consistent with those obtained by a standard maximum-likelihood approach. The method is a new approach to representation and reconstruction of data obtained by photon-limited emission tomography measurements.

  19. Representation of photon limited data in emission tomography using origin ensembles

    Science.gov (United States)

    Sitek, A.

    2008-06-01

    Representation and reconstruction of data obtained by emission tomography scanners are challenging due to high noise levels in the data. Typically, images obtained using tomographic measurements are represented using grids. In this work, we define images as sets of origins of events detected during tomographic measurements; we call these origin ensembles (OEs). A state in the ensemble is characterized by a vector of 3N parameters Y, where the parameters are the coordinates of origins of detected events in a three-dimensional space and N is the number of detected events. The 3N-dimensional probability density function (PDF) for that ensemble is derived, and we present an algorithm for OE image estimation from tomographic measurements. A displayable image (e.g. grid based image) is derived from the OE formulation by calculating ensemble expectations based on the PDF using the Markov chain Monte Carlo method. The approach was applied to computer-simulated 3D list-mode positron emission tomography data. The reconstruction errors for a 10 000 000 event acquisition for simulated ranged from 0.1 to 34.8%, depending on object size and sampling density. The method was also applied to experimental data and the results of the OE method were consistent with those obtained by a standard maximum-likelihood approach. The method is a new approach to representation and reconstruction of data obtained by photon-limited emission tomography measurements.

  20. Representation of photon limited data in emission tomography using origin ensembles

    International Nuclear Information System (INIS)

    Sitek, A

    2008-01-01

    Representation and reconstruction of data obtained by emission tomography scanners are challenging due to high noise levels in the data. Typically, images obtained using tomographic measurements are represented using grids. In this work, we define images as sets of origins of events detected during tomographic measurements; we call these origin ensembles (OEs). A state in the ensemble is characterized by a vector of 3N parameters Y, where the parameters are the coordinates of origins of detected events in a three-dimensional space and N is the number of detected events. The 3N-dimensional probability density function (PDF) for that ensemble is derived, and we present an algorithm for OE image estimation from tomographic measurements. A displayable image (e.g. grid based image) is derived from the OE formulation by calculating ensemble expectations based on the PDF using the Markov chain Monte Carlo method. The approach was applied to computer-simulated 3D list-mode positron emission tomography data. The reconstruction errors for a 10 000 000 event acquisition for simulated ranged from 0.1 to 34.8%, depending on object size and sampling density. The method was also applied to experimental data and the results of the OE method were consistent with those obtained by a standard maximum-likelihood approach. The method is a new approach to representation and reconstruction of data obtained by photon-limited emission tomography measurements

  1. Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

    NARCIS (Netherlands)

    Piers, LH; Dorgelo, J; Tio, RA; Jessurun, GAJ; Oudkerk, M; Zijlstra, F

    This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic

  2. In-situ straining and time-resolved electron tomography data acquisition in a transmission electron microscope.

    Science.gov (United States)

    Hata, S; Miyazaki, S; Gondo, T; Kawamoto, K; Horii, N; Sato, K; Furukawa, H; Kudo, H; Miyazaki, H; Murayama, M

    2017-04-01

    This paper reports the preliminary results of a new in-situ three-dimensional (3D) imaging system for observing plastic deformation behavior in a transmission electron microscope (TEM) as a directly relevant development of the recently reported straining-and-tomography holder [Sato K et al. (2015) Development of a novel straining holder for transmission electron microscopy compatible with single tilt-axis electron tomography. Microsc. 64: 369-375]. We designed an integrated system using the holder and newly developed straining and image-acquisition software and then developed an experimental procedure for in-situ straining and time-resolved electron tomography (ET) data acquisition. The software for image acquisition and 3D visualization was developed based on the commercially available ET software TEMographyTM. We achieved time-resolved 3D visualization of nanometer-scale plastic deformation behavior in a Pb-Sn alloy sample, thus demonstrating the capability of this system for potential applications in materials science. © The Author 2016. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. 21 CFR 892.1310 - Nuclear tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nuclear tomography system. 892.1310 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1310 Nuclear tomography system. (a) Identification. A nuclear tomography system is a device intended to detect nuclear radiation in the body and...

  4. CULTURA ORGANIZACIONAL: UM ESTUDO DE CASO NA EMPRESA MGO

    Directory of Open Access Journals (Sweden)

    Vagner Luís Wentz

    2012-07-01

    Full Text Available O tema cultura tem sido objeto de estudo há muitos anos, e as literaturas existentes apontam uma grande diversidade de conceitos, o que torna as organizações grandes fontes de pesquisa. A MGO, uma multinacional fabricante de produtos agrícolas, convive constantemente com mudanças de seus procedimentos, de suas tarefas do cotidiano e de comportamentos por parte de seus colaboradores, uma relação entre “novatos” e “veteranos” que, em alguns casos, é geradora de conflitos, o que pode vir a prejudicar a imagem da companhia. Diante disso, este estudo tem como objetivo geral analisar a cultura organizacional a partir da percepção das lideranças de uma unidade da empresa MGO situada em Montenegro/RS. Esta pesquisa se classifica, quanto aos procedimentos, como bibliográfica e estudo de caso; quanto aos objetivos, como descritiva; e quanto ao problema, esta pesquisa é classificada como qualitativa. A partir da análise dos dados coletados através de entrevistas semiestruturadas com as lideranças de departamentos diferentes, análise de documentos, observação participante e aplicação do teste para identificação da tipologia de cultura, pode-se identificar a cultura da organização e sugerir algumas melhorias que podem ajudar na harmonia do clima da organização. Palavras-chave: Cultura. Clima. Organização.

  5. single photon emission tomography and positron emission tomography - Part 1 (October 2012), Part 2 (October 2010)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2010-10-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) and the positron emission tomography (PET) imaging techniques. Part 1 Content: 1 - Introduction: anatomic, functional and molecular imaging; 2 - Radiotracers: chemical and physical constraints, gamma photon emitters, positon emitters, radioisotopes production, emitters type and imaging techniques; 3 - Gamma cameras; 4 - Quantification in emission tomography: attenuation, scattering, un-stationary spatial resolution; 5 - Synthesis and conclusion. Part 2 content: 1 - Positon emitters; 2 - Positons detection: Coincidence detection (electronic collimation, PET detectors with gamma cameras, dedicated PET detectors, spectrometry); PET detectors type; time-of-flight PET; 2D PET; 3D PET; 3 - Quantification in emission tomography: detected events, attenuation, scattering, fortuitous coincidences, standardisation; 4 - Common SPECT and PET problems: partial volume effect, movement, tomographic reconstruction, calibration, dead time; 5 - Synthesis and conclusion

  6. Análise de Estudos sobre Atenção Publicados em Periódicos Brasileiros

    Directory of Open Access Journals (Sweden)

    Patrícia Maria Uchôa Simões

    Full Text Available A atenção esteve presente nos estudos da Psicologia desde os introspeccionistas até a atualidade. Com a hegemonia do behaviorismo os estudos sobre atenção foram abandonados, e só no final da década de 50 e início de 60 houve uma retomada dessas questões, com o surgimento das ciências cognitivas. O presente estudo realizou uma pesquisa bibliográfica sobre o tema em periódicos brasileiros publicados entre 1999 e 2008, encontrados na base de dados do SCIELO. Foram analisados 96 artigos identificados a partir do descritor atenção para palavras-chave. A análise incidiu sobre os aspectos: ano da publicação, área do periódico e palavras-chave. Os resultados mostraram um maior número de artigos na área da Saúde, com foco na hiperatividade infantil. A análise desses resultados propõe uma discussão sobre o papel que a atenção vem ocupando nos estudos em Psicologia e sugere uma agenda de pesquisas que supere a fragmentação das análises nos estudos.

  7. 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Tuberculosis: Spectrum of Manifestations.

    Science.gov (United States)

    Agarwal, Krishan Kant; Behera, Abhishek; Kumar, Rakesh; Bal, Chandrasekhar

    2017-01-01

    The objective of this article is to provide an illustrative tutorial highlighting the utility of 18 F-fluorodeoxyglucose-positron emission tomography/computed tomography ( 18 F-FDG-PET/CT) imaging to detect spectrum of manifestations in patients with tuberculosis (TB). FDG-PET/CT is a powerful tool for early diagnosis, measuring the extent of disease (staging), and consequently for evaluation of response to therapy in patients with TB.

  8. Protean appearance of craniopharyngioma on computed tomography

    International Nuclear Information System (INIS)

    Danziger, A.; Price, H.I.

    1979-01-01

    Craniopharyngiomas present a diverse appearance on computed tomography. Histological diagnosis is not always possible, but computed tomography is of great assistance in the delineation of the tumour as well as of the degree of associated hydrocephalus. Computed tomography also enables rapid non-invasive follow-up after surgery or radiotherapy, or both

  9. Computed tomography and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography findings in adrenal candidiasis and histoplasmosis: two cases.

    Science.gov (United States)

    Altinmakas, Emre; Guo, Ming; Kundu, Uma R; Habra, Mouhammed Amir; Ng, Chaan

    2015-01-01

    We report the contrast-enhanced computed tomography (CT) and (18)F-fluorodeoxyglucose positron emission tomography findings in adrenal histoplasmosis and candidiasis. Both demonstrated bilateral hypermetabolic heterogeneous adrenal masses with limited wash-out on delayed CT. Adrenal candidiasis has not been previously reported, nor have the CT wash-out findings in either infection. The adrenal imaging findings are indistinguishable from malignancy, which is more common; but in this setting, physicians should be alert to the differential diagnosis of fungal infections, since it can be equally deadly. Published by Elsevier Inc.

  10. Use of an improved simultaneous tomography cassette in linear tomography

    International Nuclear Information System (INIS)

    Egender, G.; Pirker, E.; Gornik, E.; Innsbruck Univ.

    1984-01-01

    An improved simultaneous tomography cassette according to P. Landau was tried out for four months using four tomographs in routine work. The mode of operation is based on accurate control of the relative speeds of the individual x-ray films resulting in simultaneous imaging of 6 equidistant tomographic levels. Clinical testing was effected in 80 cases: nephrotomography, of the lungs, the hilum, and the skeleton. In particular, the article describes imaging of the renal arteries by simultaneous tomography for the purpose of finding out the cause of hypertension, and if there is suspicion of a space-occupying growth in the kidney, basing on the urogram. The specific advantages of this technique are, on the one hand, improved diagnostic efficiency (the tomograms are taken during the same respiratory phase, more rapid diagnosis especially with accident patients), and, on the other hand, an important reduction in the x-ray exposure of the patient; furthermore, the life of the x-ray tube is prolonged, and there is a definite saving of time for both patient and personnel, the image quality being comparable with that of single-layer tomography. (orig.) [de

  11. Unidade de Estudos de Mastites em Pequenos Ruminantes - estudos em ovinos de regime extensivo

    OpenAIRE

    Queiroga, Cristina; Potes, Maria Eduarda; Duarte, Elsa Maria; Marinho, Artur; Bettencourt, Carlos Manuel; Matos, Claudino; Belo, Carlos Carmona; Ribeiro, José Manuel; Vilela, Cristina Lobo

    2007-01-01

    A “Unidade de Estudo de Mastites em Pequenos Ruminantes”, formalmente constituída no âmbito do Programa Nacional de Re-equipamento Científico, da Fundação para a Ciência e a Tecnologia, vem dar corpo ao trabalho de colaboração de diversas equipas de investigação que se têm debruçado sobre a problemática das infecções intramamárias em pequenos ruminantes, nos seus aspectos de saúde animal, saúde pública veterinária e qualidade e segurança alimentar. Tem como principal objectivo criar condições...

  12. Comparing staging by positron emission tomography with contrast-enhanced computed tomography and by pathology in head and neck squamous cell carcinoma.

    Science.gov (United States)

    Qualliotine, J R; Mydlarz, W K; Chan, J Y K; Zhou, X; Wang, H; Agrawal, N

    2015-12-01

    This study aimed to evaluate the ability of positron emission tomography with contrast-enhanced computed tomography to correctly stage head and neck squamous cell carcinomas, in comparison with pathological staging. Positron emission tomography computed tomography was used to determine the tumour-node-metastasis classification and overall cancer stage in 85 head and neck squamous cell carcinoma patients who underwent pre-operative imaging using this modality and primary surgery between July 2010 and January 2013. Staging by positron emission tomography computed tomography was retrospectively compared with staging using pathological specimens. Agreement between imaging stage and pathological stage was examined by univariate and multivariate analysis both overall and for each primary tumour site. This imaging modality was 87.5 per cent sensitive and 44.8 per cent specific in identifying regional cervical metastases, and had false positive and false negative rates of 18.8 per cent and 8.2 per cent, respectively. The positive predictive and negative predictive values were 75.4 per cent and 65.0 per cent, respectively. Univariate and multivariate analyses revealed a significant agreement between positron emission tomography computed tomography and pathological node classification in older patients and for the oral cavity primary tumour site. There was significant agreement between both methods in the overall classification only for tumours classified as T3 or greater. Positron emission tomography computed tomography should be used with caution for the pre-operative staging of head and neck cancers because of its high false positive and false negative rates.

  13. Os estudos acadêmicos de literatura: uma experiência constitutiva

    Directory of Open Access Journals (Sweden)

    Eunice T. Piazza Gai

    2015-07-01

    Full Text Available O artigo apresenta uma reflexão sobre o tema dos estudos acadêmicos de literatura. Embasa-se na leitura de diversos autores, tais como Platão, Vygotsky, Compagnon, Palmer, Bruner, Secchieri, entre outros. Defende a ideia de que é necessário rever as práticas acadêmicas que consideram os textos literários de um ponto de vista exógeno. Em contrapartida, seria preferível que os estudos de literatura se voltassem para as questões da sua natureza intrínseca, ou seja, que ocorressem, a partir da reflexão sobre a especificidade do conhecimento por ela veiculado e sobre as possibilidades de constituição de sentido propiciadas pelo trabalho hermenêutico.

  14. Afetividade, ensino e aprendizagem: um estudo no GT20 da ANPEd

    Directory of Open Access Journals (Sweden)

    Elvira Cristina Martins Tassoni

    Full Text Available Este artigo traz um levantamento bibliográfico dos trabalhos apresentados no GT20 - Psicologia da Educação da ANPEd (Associação Nacional de Pós-Graduação e Pesquisa em Educação no período de 2000 a 2010. O objetivo foi rastrear as produções científicas mais recentes que discutem a afetividade e sua relação com os processos de ensino e aprendizagem. Apresenta as perspectivas teóricas em que os estudos sobre a afetividade foram abordados e em que medida tais estudos discutem as influências entre os aspectos afetivos e os processos de ensino e aprendizagem. Os trabalhos foram selecionados segundo os procedimentos metodológicos da análise de conteúdo fundamentada em Bardin (1977. Os resultados permitiram a construção de um panorama a respeito dos estudos sobre afetividade, apontando tendências, períodos em que as discussões sobre o tema foram mais intensas e, sobretudo, demonstrando que tal temática vem marcando presença constante nas discussões das Reuniões Anuais da ANPEd.

  15. Reduction of variable-truncation artifacts from beam occlusion during in situ x-ray tomography

    Science.gov (United States)

    Borg, Leise; Jørgensen, Jakob S.; Frikel, Jürgen; Sporring, Jon

    2017-12-01

    Many in situ x-ray tomography studies require experimental rigs which may partially occlude the beam and cause parts of the projection data to be missing. In a study of fluid flow in porous chalk using a percolation cell with four metal bars drastic streak artifacts arise in the filtered backprojection (FBP) reconstruction at certain orientations. Projections with non-trivial variable truncation caused by the metal bars are the source of these variable-truncation artifacts. To understand the artifacts a mathematical model of variable-truncation data as a function of metal bar radius and distance to sample is derived and verified numerically and with experimental data. The model accurately describes the arising variable-truncation artifacts across simulated variations of the experimental setup. Three variable-truncation artifact-reduction methods are proposed, all aimed at addressing sinogram discontinuities that are shown to be the source of the streaks. The ‘reduction to limited angle’ (RLA) method simply keeps only non-truncated projections; the ‘detector-directed smoothing’ (DDS) method smooths the discontinuities; while the ‘reflexive boundary condition’ (RBC) method enforces a zero derivative at the discontinuities. Experimental results using both simulated and real data show that the proposed methods effectively reduce variable-truncation artifacts. The RBC method is found to provide the best artifact reduction and preservation of image features using both visual and quantitative assessment. The analysis and artifact-reduction methods are designed in context of FBP reconstruction motivated by computational efficiency practical for large, real synchrotron data. While a specific variable-truncation case is considered, the proposed methods can be applied to general data cut-offs arising in different in situ x-ray tomography experiments.

  16. Magnetic resonance tomography in syringomyelia

    International Nuclear Information System (INIS)

    Koehler, D.; Treisch, J.; Hertel, G.; Schoerner, W.; Fiegler, W.; Staedtisches Rudolf-Virchow Krankenhaus, Berlin

    1985-01-01

    Thirteen patients with a clinical diagnosis of syringomyelia were examined by nuclear tomography (0.35 T magnet) in the spin-echo mode. In all thirteen patients, the T1 images (Se 400/35) showed a longitudinal cavity with a signal intensity of CSF. The shape and extent of the syrinx could be adequately demonstrated in 12 of the 13 examinations. Downward displacement of the cerebellar tonsils was seen in eight cases. The examination took between half and one hour. Advantages of magnetic resonance tomography (nuclear tomography) include the absence of artifacts, images in the line of the lesion and its non-invasiveness. (orig.) [de

  17. Diagnostic utility of fluorodeoxyglucose positron emission tomography/computed tomography in pyrexia of unknown origin

    International Nuclear Information System (INIS)

    Singh, Nidhi; Kumar, Rakesh; Malhotra, Arun; Bhalla, Ashu Seith; Kumar, Uma; Sood, Rita

    2005-01-01

    The present study was undertaken to evaluate the diagnostic utility of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) in patients presenting as pyrexia of unknown origin (PUO). Forty-seven patients (31 males and 16 females; mean age of 42.7 ± 19.96 years) presenting as PUO to the Department of Medicine at the All India Institute of Medical Sciences, New Delhi over a period of 2 years underwent F-18 FDG PET/CT. PET ⁄ CT was considered supportive when its results correlated with the final definitive diagnosis. Final diagnosis was made on the basis of combined evaluation of history, clinical findings, investigations, and response to treatment. Thirty-five PET/CT studies (74.5%) were positive. However, only 18 (38.3%) were supportive of the final diagnosis. In three patients (6.4%), PET/CT was considered diagnostic as none of the other investigations including contrast-enhanced computed tomography of chest and abdomen, and directed tissue sampling could lead to the final diagnosis. All these three patients were diagnosed as aortoarteritis. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography is an important emerging modality in the workup of PUO. It supported the final diagnosis in 38% of our patients and was diagnostic in 6.4% of patients. Thus, PET/CT should only be considered as second-line investigation for the diagnostic evaluation of PUO; especially in suspected noninfectious inflammatory disorders

  18. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  19. Frequency domain fluorescent diffuse tomography of small animals with DsRed2-expressed tumors

    Science.gov (United States)

    Turchin, Ilya V.; Savitsky, Alexander P.; Kamensky, Vladislav A.; Plehanov, Vladimir I.; Orlova, Anna G.; Sergeeva, Ekaterina A.; Kleshnin, Mikhail S.; Shirmanova, Marina V.

    2006-02-01

    The main applications of fluorescent proteins (FPs) are monitoring tumor growth, angiogenesis, metastases formation and effects of new classes of drugs. Different types of tomography allow fluorescence imaging of tumors located deep in human or animal tissue. These techniques were used for investigation of the distribution of near-infrared fluorescent probes, but only a few works are devoted to fluorescence tomography in visible light. In this work, preliminary results of the frequency domain fluorescent diffuse tomography (FD FDT) method in application to DsRed2 protein as a fluorescent agent are presented. For the first step of our experiments we utilized second harmonic generation of Nd:YAG laser (532 nm) modulated by low frequency (1 kHz) in the experimental setup. The transilluminative planar configuration was used in the setup. A series of model experiments has been conducted and show good agreement between theoretical and experimental fluorescence intensity. Post mortem experiments with capsules containing DsRed2 and scattering solution introduced into esophagus of rats to simulate tumor formation have been conducted. The results of these experiments show that sensitivity of the setup is sufficient to detect DsRed2 in concentrations similar to those in FP-expressed tumor, but the contrast is not enough high to separate fluorescence of DsRed2 and surrounding tissues. The setup can be significantly improved by utilizing high-frequency modulation (110 MHz using acousto-optical modulator) of the excitation light and precise phase measurements due to difference in fluorescence life-time of FPs and surrounding tissues. An algorithm of processing a fluorescent image based on calculating zero of maximum curvature was employed for detection of fluorescent inclusions boundaries in the image.

  20. Dynamic emission tomography of regional cerebral blood flow

    International Nuclear Information System (INIS)

    Lassen, N.A.

    1984-01-01

    The author reviews three tomographic methods for measuring the regional cerebral blood flow: single photon transmission tomography; dual photon emission tomography; and single photon emission tomography. The latter technique is discussed in detail. (Auth.)

  1. Interfaces entre a Pedagogia do Teatro e os Estudos da Performance

    Directory of Open Access Journals (Sweden)

    Luciana Hartmann

    2014-11-01

    Full Text Available http://dx.doi.org/10.5902/1984644413816Este texto propõe o debate sobre pontos de contato entre a nova terminologia utilizada nos processos de ensino-aprendizagem em teatro, a Pedagogia do Teatro, e os Estudos da Performance. Partindo de uma análise dos Parâmetros Curriculares Nacionais (PCN Arte I e II e das perspectivas histórico-críticas trazidas por alguns dos principais pesquisadores brasileiros que tem se dedicado ao tema, busca-se, ao longo do texto, refletir sobre as contribuições que os Estudos da Performance podem trazer para o desenvolvimento do campo da Pedagogia do Teatro.

  2. Introduction to Seismic Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, Charlotte Anne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-21

    Tomography is a method of obtaining an image of a 3d object by observing the behavior of energy transmissions through the object. The image is obtained by Interrogating the object with Energy sources at a variety of Locations and observing the Object’s effects on the energy at a Variety of sensors. Tomography was first Used to build 3-dimensional Scans through Human bodies. These Are called computed Tomographic (ct) scans.

  3. MicroComputed Tomography: Methodology and Applications

    International Nuclear Information System (INIS)

    Stock, Stuart R.

    2009-01-01

    Due to the availability of commercial laboratory systems and the emergence of user facilities at synchrotron radiation sources, studies of microcomputed tomography or microCT have increased exponentially. MicroComputed Technology provides a complete introduction to the technology, describing how to use it effectively and understand its results. The first part of the book focuses on methodology, covering experimental methods, data analysis, and visualization approaches. The second part addresses various microCT applications, including porous solids, microstructural evolution, soft tissue studies, multimode studies, and indirect analyses. The author presents a sufficient amount of fundamental material so that those new to the field can develop a relative understanding of how to design their own microCT studies. One of the first full-length references dedicated to microCT, this book provides an accessible introduction to field, supplemented with application examples and color images.

  4. Use of computed tomography and positron emission tomography/computed tomography for staging of local extent in patients with malignant pleural mesothelioma.

    Science.gov (United States)

    Frauenfelder, Thomas; Kestenholz, Peter; Hunziker, Roger; Nguyen, Thi Dan Linh; Fries, Martina; Veit-Haibach, Patrick; Husmann, Lars; Stahel, Rolf; Weder, Walter; Opitz, Isabelle

    2015-01-01

    The objective of this study was to determine the diagnostic value of computed tomography (CT) and positron emission tomography (PET)/CT for staging of malignant pleural mesothelioma (MPM) in patients undergoing induction chemotherapy. Sixty-two patients (median age, 61 years; female: n = 9) with proven MPM underwent CT after induction chemotherapy. Of these, 28 underwent additional PET/CT. Extrapleural pneumonectomy was performed for pathological TNM staging. Clinical TNM stage was assessed by 3 independent readers. Relative and absolute underestimation and overestimation were compared with pathological tumor stage. Sensitivity, specificity, and accuracy for differentiation between stages T2 and T3 were assessed. Interobserver agreement between the readers was analyzed (κ). Positron emission tomography/CT and CT underestimated T stage in up to 30% of the cases. Positron emission tomography/CT had a higher accuracy for tumor extent compared with CT (PET/CT: 0.92; CT: 0.84). The accuracy for nodal staging was higher for CT than for PET/CT (PET/CT: 0.78; CT: 0.87). Concerning International Mesothelioma Interest Group classification, PET/CT improved the accuracy of preoperative staging compared with CT (PET/CT: 0.91; CT: 0.82). Interobserver agreement was moderate for CT (0.48-0.62) and good for PET/CT (0.64-0.83) for T staging. For nodal staging, interobserver agreement was fair to moderate for CT and good for PET/CT (CT: 0.37-0.51; PET/CT: 0.73-0.76). Positron emission tomography/CT is more accurate and has a lower interobserver variability for clinical intrathoracic staging of MPM compared with CT. Nevertheless PET/CT underestimated tumor stage in a substantial number of cases, showing the need for a more accurate imaging technology or approach.

  5. Estudo do comportamento de RSU em uma célula experimental e suas correlações com aspectos microbiológicos, físicos e químicos Behavior study of MSW in an experimental cell and its correlations with microbiological, physical and chemical aspects

    Directory of Open Access Journals (Sweden)

    Veruschka Escarião Dessoles Monteiro

    2006-09-01

    Full Text Available Células experimentais (lisímetros possibilitam entender o comportamento de aterros de RSU e representam uma técnica bastante interessante para obter parâmetros de projetos, dimensionamento e construção de aterros, além do mais pode fornecer contribuições na área de saneamento através de monitoramento de processos. O objetivo deste trabalho é avaliar o processo biodegradativo dos resíduos depositados em uma célula experimental correlacionando parâmetros como recalque, temperatura e contagem de microrganismos. O monitoramento mostrou que há uma relação entre estes parâmetros. Verificou-se que a temperatura no lisímetro variou no decorrer do processo possivelmente devido às mudanças de fases de decomposição dos resíduos. Os estudos vislumbram uma nova abordagem para recalques em RSU mostrando a ocorrência de três fazes distintas de deformações verticais e a íntima ligação de processos biodegradativos e aspectos mecânicos.Experimental cells (lysimeters make possible to understand the landfill behavior of MSW and represent a very interesting technique for the obtainment of projects parameters, design and constructions of landfills. Besides that, they provide contributions to the sanitation area through processes monitoring. The purpose of this paper is to evaluate the solid waste biodegradation process deposited in an experimental cell correlating parameters like settlement, temperature and microorganisms counting. The monitoring showed that there is a relation between these parameters. It was observed that the temperature in the lysimeter varied in the course of the process, possibly because of the changes in the stages of the solid waste decomposition. The studies descry a new approach to settlements in MSW showing that there are three different stages of vertical deformations and the close connection of biodegradation processes and mechanical aspects.

  6. Multislice quantitative computed tomography allows early detection of bone mineral density alterations induced by atherogenic diet in a growing rat experimental model

    International Nuclear Information System (INIS)

    Gubert, M.J.; Monforte, F.; Calo, C.; Lylyk, P.; Friedman, M.F.; Gamba, C.A.

    2012-01-01

    Purpose. To demonstrate the utility of Multislice Quantitative Computed Tomography (MS-QCT) in the early detection of mandibular bone mineral density (BMD) alterations induced by an atherogenic diet in a growing rat experimental model. Materials and Methods. Male weanling Wistar rats (n =16) were divided by body weight (Wt) into 2 groups: control (C) and experimental (E), with no significant differences in the mean initial Wt (p>0.05). C was fed rodent stock diet ad libitum, and E an atherogenic diet for 3 weeks (3w). Zoometry (body weight and length) and diet intake (g/100g rat/day) were monitored. At 3 w in serum (mg/dL) lipidlipoprotein profile was studied: total cholesterol (t-C), triglycerides (TG), high-density lipoprotein cholesterol (HDL-C), non-HDL cholesterol (non-HDL-C) and MSQCT (Philips 64 CT, quantified with the eFilm Workstation 2.1) in seven mandibular areas (MA): n. 1 to 4: from chin to mandibular foramen, n. 5: coronoid process, n. 6: condylar process, n. 7: angular process. Statistics: Pearson's correlation between BMD in each MA and serum t-C. p 0.05). Correlation coefficients (r) and their significance levels (p) were relevant in 5/7 MA. MA1:-0.580 (p=0.019), MA2:-0.709 (p=0.002), MA3:-0.635 (p=0.008), MA5:-0.674 (p=0.004), MA6:-0.564 (p=0.023). Conclusions. These results suggest that MS-QCT is an imaging diagnostic method that allows the early detection of mandible bone architecture alterations induced by an atherogenic diet. Inverse correlation between BMD and t-C would indicate an association between an atherogenic diet intake and potential temporomandibular disorders. (authors)

  7. Oblique hilar tomography, computed tomography, and mediastinoscopy for prethoracotomy staging of bronchogenic carcinoma

    International Nuclear Information System (INIS)

    Khan, A.; Gersten, K.C.; Garvey, J.; Khan, F.A.; Steinberg, H.

    1985-01-01

    Preoperative oblique hilar tomography was used to evaluate hilar lymph nodes in 150 patients with clinically resectable bronchogenic carcinoma. CT was also used in the evaluation of mediastinal lymph nodes in 50 of these patients. Subsequently, all patients underwent mediastinoscopy and/or thoracotomy. Hilar and mediastinal nodes were evaluated for the presence of metastasis, and these findings were then correlated with the radiographic findings of oblique hilar tomography and CT. CT was found to be a reliable method for prethoracotomy staging of bronchogenic carcinoma and for selecting patients for mediastinoscopy. Thus patients with negative mediastinal CT need not undergo mediastinoscopy prior to thoracotomy, while mediastinoscopy and biopsy should be done in patients with enlarged mediastinal nodes on CT. Oblique hilar tomography is an accurate method for evaluation of hilar adenopathy and for predicting mediastinal involvement by extrapolation

  8. Practical implementation of spectral-intensity dispersion-canceled optical coherence tomography with artifact suppression

    Science.gov (United States)

    Shirai, Tomohiro; Friberg, Ari T.

    2018-04-01

    Dispersion-canceled optical coherence tomography (OCT) based on spectral intensity interferometry was devised as a classical counterpart of quantum OCT to enhance the basic performance of conventional OCT. In this paper, we demonstrate experimentally that an alternative method of realizing this kind of OCT by means of two optical fiber couplers and a single spectrometer is a more practical and reliable option than the existing methods proposed previously. Furthermore, we develop a recipe for reducing multiple artifacts simultaneously on the basis of simple averaging and verify experimentally that it works successfully in the sense that all the artifacts are mitigated effectively and only the true signals carrying structural information about the sample survive.

  9. Margem crítica e legitimação nos estudos para a paz

    Directory of Open Access Journals (Sweden)

    José Manuel Pureza

    2012-10-01

    Full Text Available Os Estudos para a Paz, constituídos historicamente como conhecimento crítico e, portanto, alternativo à ciência normal em Relações Internacionais, vieram, nos anos noventa, a ser cooptados pelas estruturas de regulação do sistema internacional como fundamento de muitas das opções postas em prática sobretudo no quadro dos processos de reconstrução pós-bélica. Neste contexto, o resgate da linhagem crítica dos Estudos para a Paz implica hoje duas opções radicais. A primeira é a da qualificação da paz pretendida como paz sustentável. A segunda é a da descolonização epistemológica dos Estudos para a Paz.

  10. Uso do conceito de aprendizagem em estudos relacionados ao trabalho e organizações

    Directory of Open Access Journals (Sweden)

    Francisco Antonio Coelho Junior

    2008-01-01

    Full Text Available A literatura em comportamento organizacional apresenta diversos estudos referenciando o conceito aprendizagem aplicado no âmbito das organizações. Porém, verifica-se o uso pouco crítico ou sistemático deste conceito. O objetivo do presente artigo consiste em realizar uma análise conceitual do termo aprendizagem, justificando sua transposição para estudos organizacionais. Aplicaram-se técnicas de análise conceitual propostas por Ryle. Como resultado, verificou-se que a natureza multifacetada do conceito de aprendizagem favorece o advento das diversas definições associadas a ele. Espera-se que haja maior sistematicidade acerca do uso do termo aprendizagem aplicado em estudos organizacionais, considerando seus níveis de análise e as dimensões presentemente discutidas.

  11. Reducing the effects of acoustic heterogeneity with an iterative reconstruction method from experimental data in microwave induced thermoacoustic tomography

    International Nuclear Information System (INIS)

    Wang, Jinguo; Zhao, Zhiqin; Song, Jian; Chen, Guoping; Nie, Zaiping; Liu, Qing-Huo

    2015-01-01

    Purpose: An iterative reconstruction method has been previously reported by the authors of this paper. However, the iterative reconstruction method was demonstrated by solely using the numerical simulations. It is essential to apply the iterative reconstruction method to practice conditions. The objective of this work is to validate the capability of the iterative reconstruction method for reducing the effects of acoustic heterogeneity with the experimental data in microwave induced thermoacoustic tomography. Methods: Most existing reconstruction methods need to combine the ultrasonic measurement technology to quantitatively measure the velocity distribution of heterogeneity, which increases the system complexity. Different to existing reconstruction methods, the iterative reconstruction method combines time reversal mirror technique, fast marching method, and simultaneous algebraic reconstruction technique to iteratively estimate the velocity distribution of heterogeneous tissue by solely using the measured data. Then, the estimated velocity distribution is used subsequently to reconstruct the highly accurate image of microwave absorption distribution. Experiments that a target placed in an acoustic heterogeneous environment are performed to validate the iterative reconstruction method. Results: By using the estimated velocity distribution, the target in an acoustic heterogeneous environment can be reconstructed with better shape and higher image contrast than targets that are reconstructed with a homogeneous velocity distribution. Conclusions: The distortions caused by the acoustic heterogeneity can be efficiently corrected by utilizing the velocity distribution estimated by the iterative reconstruction method. The advantage of the iterative reconstruction method over the existing correction methods is that it is successful in improving the quality of the image of microwave absorption distribution without increasing the system complexity

  12. Optical Coherence Tomography of the Aging Kidney.

    Science.gov (United States)

    Andrews, Peter M; Wang, Hsing-Wen; Guo, Hengchang; Anderson, Erik; Falola, Reuben; Chen, Yu

    2016-12-01

    The aging kidney exhibits a progressive decline in renal function with characteristic histopathologic changes and is a risk factor for renal transplant. However, the degree to which the kidney exhibits this decline depends on several factors that vary from one individual to the next. Optical coherence tomography is an evolving noninvasive imaging technology that has recently been used to evaluate acute tubular necrosis of living-human donor kidneys before their transplant. With the increasing use of kidneys from older individuals, it is important to determine whether optical coherence tomography also can distinguish the histopathology associated with aging. In this investigation, we used Munich-Wistar rats to evaluate the ability of optical coherence tomography to detect histopathologic changes associated with aging. Optical coherence tomography observations were correlated with renal function and conventional light microscopic evaluation of these same kidneys. With the onset of severe proteinuria at 10 to 12 months of age, optical coherence tomography revealed tubular necrosis/atrophy, interstitial fibrosis, tubular dilation, and glomerulosclerosis. With a further deterioration in kidney function at 16 to 18 months of age (as indicated by rising creatinine levels), optical coherence tomography revealed more extensive interstitial fibrosis and tubular atrophy, increased tubular dilation with cyst formation and more sclerotic glomeruli. The foregoing observations suggest that optical coherence tomography can be used to detect the histopathology of progressive nephropathy associated with aging.

  13. Efeito da histamina na regeneração hepática: estudo experimental em ratos

    Directory of Open Access Journals (Sweden)

    Biondo-Simões Maria de Lourdes Pessole

    2000-01-01

    Full Text Available Muitas substâncias têm sido utilizadas após hepatectomias parciais a fim de conhecer como elas atuam sobre o processo de regeneração hepática. Adequado fluxo sangüíneo parece ter muita importância neste processo. Autores descreveram, após hepatectomias em ratos, elevação dos níveis plasmáticos de histamina. Substâncias inibidoras da histidina-decarboxilase e da histaminase leva a elevação da histamina endógena com vasodilatação sinusoidal e aceleração da regeneração hepática. No presente estudo busca-se conhecer a influência da histamina exógena administrada à ratos parcialmente hepatectomizados. Utilizaram-se 32 ratos Wistar que sofreram hepatectomia de aproximadamente 67% da víscera. Os animais do grupo experimento receberam por via subcutânea 0,5 mg/Kg/dia de histamina e os do grupo controle igual volume de solução salina isotônica. As aferições foram realizadas com 36 horas e 7 dias. A avaliação do peso da víscera não mostrou diferença entre os grupos. O número de figuras de mitose em 10 campos foi maior no grupo experimento com 36 horas (p=0,010. No sétimo dia o número delas era semelhante nos dois grupos. Concluiu-se que a administração de histamina exógena, talvez pela sua vida média curta, aumenta o número de figuras de mitose no início do processo, não interferindo na regeneração ao final de 7 dias.

  14. Optical diffraction tomography in an inhomogeneous background medium

    International Nuclear Information System (INIS)

    Devaney, A; Cheng, J

    2008-01-01

    The filtered back-propagation algorithm (FBP algorithm) is a computationally fast and efficient inversion algorithm for reconstructing the 3D index of refraction distribution of weak scattering samples in free space from scattered field data collected in a set of coherent optical scattering experiments. This algorithm is readily derived using classical Fourier analysis applied to the Born or Rytov weak scattering models appropriate to scatterers embedded in a non-attenuating uniform background. In this paper, the inverse scattering problem for optical diffraction tomography (ODT) is formulated using the so-called distorted wave Born and Rytov approximations and a generalized version of the FBP algorithm is derived that applies to weakly scattering samples that are embedded in realistic, multiple scattering ODT experimental configurations. The new algorithms are based on the generalized linear inverse of the linear transformation relating the scattered field data to the complex index of refraction distribution of the scattering samples and are in the form of a superposition of filtered data, computationally back propagated into the ODT experimental configuration. The paper includes a computer simulation comparing the generalized Born and Rytov based FBP inversion algorithms as well as reconstructions generated using the generalized Born based FBP algorithm of a step index optical fiber from experimental ODT data

  15. Preliminary results for X-ray phase contrast micro-tomography on the biomedical imaging beamline at SSRF

    International Nuclear Information System (INIS)

    Chen Rongchang; Du Guohao; Xie Honglan; Deng Biao; Tong Yajun; Hu Wen; Xue Yanling; Chen Can; Ren Yuqi; Zhou Guangzhao; Wang Yudan; Xiao Tiqiao; Xu Hongjie; Zhu Peiping

    2009-01-01

    With X-ray phase contrast micro-tomography(CT), one is able to obtain edge-enhanced image of internal structure of the samples. This allows visualization of the fine internal features for biology tissues, which is not able to resolve by conventional absorption CT. After preliminary modulation, monochromatic X-rays (8-72.5 keV) are available for experiments on the experimental station of the biomedical imaging beamline at Shanghai Synchrotron Radiation Facility(SSRF). In this paper, we report the in line phase contrast micro-tomography(IL-XPCT) of biology sample (locust) on the beamline. The reconstruct slice images and three dimensional rendering images of the locust were obtained, with clearly visible images of locus's wing, surface texture and internal tissue distribution. (authors)

  16. Experimental Investigation of 2D thermal signature and 3D X-Ray Computed Tomography in contrasting Wettable and Water-Repellent Beads

    Science.gov (United States)

    Alsih, Abdulkareem; Flavel, Richard; McGrath, Gavan

    2017-04-01

    This study presents experimental results investigating spatial patterns of infiltration and evaporation in heterogeneous water repellent media. Infrared camera measurements and 3D X-ray computed tomography imaging was performed across wet-dry cycles on glass beads with engineered patches of water repellence. The imaging revealed spatial variability in infiltration and the redistribution of water in the media resulting in differences in relative evaporation rates during drying. It appears that the spatial organization of the heterogeneity play a role in the breakdown of water repellence at the interface of the two media. This suggests a potential mechanism for self-organization of repellency spatial patterns in field soils. At the interface between wettable and water repellent beads a lateral drying front propagates towards the wettable beads from the repellent beads. During this drying the relative surface temperatures change from a relatively cooler repellent media surface to a relatively cooler wettable media surface indicating the changes in evaporative water loss between the beads of varying water repellence. The lateral drying front was confirmed using thermography in a small-scale model of glass beads with chemically induced repellence and then subjected to 3D X-ray imaging. Pore-scale imaging identified the hydrology at the interface of the two media and at the drying front giving insights into the physics of water flow in water repellent soil.

  17. Three-dimensional fluorescence lifetime tomography

    International Nuclear Information System (INIS)

    Godavarty, Anuradha; Sevick-Muraca, Eva M.; Eppstein, Margaret J.

    2005-01-01

    Near-infrared fluorescence tomography using molecularly targeted lifetime-sensitive, fluorescent contrast agents have applications for early-stage cancer diagnostics. Yet, although the measurement of fluorescent lifetime imaging microscopy (FLIM) is extensively used in microscopy and spectroscopy applications, demonstration of fluorescence lifetime tomography for medical imaging is limited to two-dimensional studies. Herein, the feasibility of three-dimensional fluorescence-lifetime tomography on clinically relevant phantom volumes is established, using (i) a gain-modulated intensified charge coupled device (CCD) and modulated laser diode imaging system, (ii) two fluorescent contrast agents, e.g., Indocyanine green and 3-3'-Diethylthiatricarbocyanine iodide differing in their fluorescence lifetime by 0.62 ns, and (iii) a two stage approximate extended Kalman filter reconstruction algorithm. Fluorescence measurements of phase and amplitude were acquired on the phantom surface under different target to background fluorescence absorption (70:1, 100:1) and fluorescence lifetime (1:1, 2.1:1) contrasts at target depths of 1.4-2 cm. The Bayesian tomography algorithm was employed to obtain three-dimensional images of lifetime and absorption owing to the fluorophores

  18. Roles of computed tomography and [18F]fluorodeoxyglucose-positron emission tomography/computed tomography in the characterization of multiple solitary solid lung nodules

    OpenAIRE

    Travaini, LL; Trifirò, G; Vigna, PD; Veronesi, G; De Pas, TM; Spaggiari, L; Paganelli, G; Bellomi, M

    2012-01-01

    The purpose of this study is to compare the performance of multidetector computed tomography (CT) and positron emission tomography/CT (PET/CT) with [18F]fluorodeoxyglucose in the diagnosis of multiple solitary lung nodules in 14 consecutive patients with suspicious lung cancer. CT and PET/CT findings were reviewed by a radiologist and nuclear medicine physician, respectively, blinded to the pathological diagnoses of lung cancer, considering nodule size, shape, and location (CT) and maximum st...

  19. Automated discrete electron tomography - Towards routine high-fidelity reconstruction of nanomaterials.

    Science.gov (United States)

    Zhuge, Xiaodong; Jinnai, Hiroshi; Dunin-Borkowski, Rafal E; Migunov, Vadim; Bals, Sara; Cool, Pegie; Bons, Anton-Jan; Batenburg, Kees Joost

    2017-04-01

    Electron tomography is an essential imaging technique for the investigation of morphology and 3D structure of nanomaterials. This method, however, suffers from well-known missing wedge artifacts due to a restricted tilt range, which limits the objectiveness, repeatability and efficiency of quantitative structural analysis. Discrete tomography represents one of the promising reconstruction techniques for materials science, potentially capable of delivering higher fidelity reconstructions by exploiting the prior knowledge of the limited number of material compositions in a specimen. However, the application of discrete tomography to practical datasets remains a difficult task due to the underlying challenging mathematical problem. In practice, it is often hard to obtain consistent reconstructions from experimental datasets. In addition, numerous parameters need to be tuned manually, which can lead to bias and non-repeatability. In this paper, we present the application of a new iterative reconstruction technique, named TVR-DART, for discrete electron tomography. The technique is capable of consistently delivering reconstructions with significantly reduced missing wedge artifacts for a variety of challenging data and imaging conditions, and can automatically estimate its key parameters. We describe the principles of the technique and apply it to datasets from three different types of samples acquired under diverse imaging modes. By further reducing the available tilt range and number of projections, we show that the proposed technique can still produce consistent reconstructions with minimized missing wedge artifacts. This new development promises to provide the electron microscopy community with an easy-to-use and robust tool for high-fidelity 3D characterization of nanomaterials. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. 4D Electron Tomography

    Science.gov (United States)

    Kwon, Oh-Hoon; Zewail, Ahmed H.

    2010-06-01

    Electron tomography provides three-dimensional (3D) imaging of noncrystalline and crystalline equilibrium structures, as well as elemental volume composition, of materials and biological specimens, including those of viruses and cells. We report the development of 4D electron tomography by integrating the fourth dimension (time resolution) with the 3D spatial resolution obtained from a complete tilt series of 2D projections of an object. The different time frames of tomograms constitute a movie of the object in motion, thus enabling studies of nonequilibrium structures and transient processes. The method was demonstrated using carbon nanotubes of a bracelet-like ring structure for which 4D tomograms display different modes of motion, such as breathing and wiggling, with resonance frequencies up to 30 megahertz. Applications can now make use of the full space-time range with the nanometer-femtosecond resolution of ultrafast electron tomography.

  1. Aspectos da tomografia de coerência óptica na doença de Stargardt: relato de caso Optical coherence tomography aspects of Stargardt's disease: case report

    Directory of Open Access Journals (Sweden)

    Enéias Bezerra Gouveia

    2006-08-01

    Full Text Available O termo fundus flavimaculatus (doença de Stargardt descreve um grupo de distrofias maculares hereditárias caracterizadas por múltiplos "flecks" amarelados em nível do epitélio pigmentar da retina. Os autores descrevem os achados de tomografia de coerência óptica (OCT em paciente portador de doença de Stargardt e sugerem que a OCT tem validade como exame subsidiário no estudo das características da retina de pacientes portadores da doença de Stargardt, embora estudos envolvendo maior número de pacientes sejam indicados para permitir traçar-se o perfil das alterações mais comuns nestes casos.The term fundus flavimaculatus (Stargardt disease describes a group of inherited macular dystrophies characterized by multiple yellow to yellow-white flecks at the level of the retinal pigment epithelium. The authors describe findings in the patient with Stargardt's disease using optical coherence tomography (OCT, and suggest the examination to be valid as subsidiary method in the study of the characteristics of the retina in Stargardt's disease patients, but studies involving a series of patients should be able to show the most frequent findings in these cases.

  2. Computed tomography in renal trauma

    International Nuclear Information System (INIS)

    Brueck, W.; Eisenberger, F.; Buck, J.

    1981-01-01

    In a group of 19 patients suffering from flank trauma and gross hematuria the diagnostic value of angiography was compared with that of computed tomography. The cases that underwent both tests were found to have the some diagnosis of rupture of the kidney. Typical CT-findings in kidney rupture are demonstrated. Whereas angiography presents an exact picture of the arterial system of the kidney, including its injures computed tomography reveals the extent of organ lesons by showing extra- and intrarenal hematomas. If surgery is planned angiography is still mandatory, whereby the indication is largely determined by the clinical findings. Computed tomography as a non-invasive method is equally suitable for follow-ups. (orig.) [de

  3. Photons-based medical imaging - Radiology, X-ray tomography, gamma and positrons tomography, optical imaging; Imagerie medicale a base de photons - Radiologie, tomographie X, tomographie gamma et positons, imagerie optique

    Energy Technology Data Exchange (ETDEWEB)

    Fanet, H.; Dinten, J.M.; Moy, J.P.; Rinkel, J. [CEA Leti, Grenoble (France); Buvat, I. [IMNC - CNRS, Orsay (France); Da Silva, A. [Institut Fresnel, Marseille (France); Douek, P.; Peyrin, F. [INSA Lyon, Lyon Univ. (France); Frija, G. [Hopital Europeen George Pompidou, Paris (France); Trebossen, R. [CEA-Service hospitalier Frederic Joliot, Orsay (France)

    2010-07-01

    This book describes the different principles used in medical imaging. The detection aspects, the processing electronics and algorithms are detailed for the different techniques. This first tome analyses the photons-based techniques (X-rays, gamma rays and visible light). Content: 1 - physical background: radiation-matter interaction, consequences on detection and medical imaging; 2 - detectors for medical imaging; 3 - processing of numerical radiography images for quantization; 4 - X-ray tomography; 5 - positrons emission tomography: principles and applications; 6 - mono-photonic imaging; 7 - optical imaging; Index. (J.S.)

  4. Adaptive multiresolution method for MAP reconstruction in electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Acar, Erman, E-mail: erman.acar@tut.fi [Department of Signal Processing, Tampere University of Technology, P.O. Box 553, FI-33101 Tampere (Finland); BioMediTech, Tampere University of Technology, Biokatu 10, 33520 Tampere (Finland); Peltonen, Sari; Ruotsalainen, Ulla [Department of Signal Processing, Tampere University of Technology, P.O. Box 553, FI-33101 Tampere (Finland); BioMediTech, Tampere University of Technology, Biokatu 10, 33520 Tampere (Finland)

    2016-11-15

    3D image reconstruction with electron tomography holds problems due to the severely limited range of projection angles and low signal to noise ratio of the acquired projection images. The maximum a posteriori (MAP) reconstruction methods have been successful in compensating for the missing information and suppressing noise with their intrinsic regularization techniques. There are two major problems in MAP reconstruction methods: (1) selection of the regularization parameter that controls the balance between the data fidelity and the prior information, and (2) long computation time. One aim of this study is to provide an adaptive solution to the regularization parameter selection problem without having additional knowledge about the imaging environment and the sample. The other aim is to realize the reconstruction using sequences of resolution levels to shorten the computation time. The reconstructions were analyzed in terms of accuracy and computational efficiency using a simulated biological phantom and publically available experimental datasets of electron tomography. The numerical and visual evaluations of the experiments show that the adaptive multiresolution method can provide more accurate results than the weighted back projection (WBP), simultaneous iterative reconstruction technique (SIRT), and sequential MAP expectation maximization (sMAPEM) method. The method is superior to sMAPEM also in terms of computation time and usability since it can reconstruct 3D images significantly faster without requiring any parameter to be set by the user. - Highlights: • An adaptive multiresolution reconstruction method is introduced for electron tomography. • The method provides more accurate results than the conventional reconstruction methods. • The missing wedge and noise problems can be compensated by the method efficiently.

  5. AÇÃO DO OMENTO NA CICATRIZAÇÃO DE ANASTOMOSES COLÔNICAS. ESTUDO EXPERIMENTAL EM RATOS

    Directory of Open Access Journals (Sweden)

    Greca Fernando Hintz

    1998-01-01

    Full Text Available Desde o século XIX o omento maior vem sendo utilizado em diferentes procedimentos cirúrgicos. O objetivo desse estudo foi avaliar os efeitos da omentoplastia na cicatrização de anastomoses colônicas em ratos. Utilizaram-se 64 ratos machos, que foram divididos em 4 grupos (A,AN,B,C. Realizou-se uma anastomose colônica situada há 5 cm da borda anal, de três maneiras diferentes: para os grupos A e AN , anastomose padrão com 8 pontos seromusculares; para o grupo B, anastomose isquêmica e, para o grupo C uma anastomose deficiente com apenas 4 pontos. Na metade dos animais de cada grupo a anastomose foi recoberta com o omento e desta forma obteve-se os subgrupos AO, ANO, BO, CO. No grupo AN e ANO utilizou-se tinta nanquim para avaliar a neovascularizção. Todos os animais foram submetidos a eutanásia no 7o dia de pós-operatório. Concluiu-se que a utilização da omentoplastia promoveu, uma neovascularização na área de anastomose, aumentou a presença de colágeno e levou a uma diminuição da presença de aderências próximo da linha de sutura.

  6. Increased fluoro-deoxy-D-glucose uptake on positron emission tomography-computed tomography postbronchoalveolar lavage: a potential cause of radiologic misinterpretation.

    LENUS (Irish Health Repository)

    Leong, Sum

    2011-08-01

    Cytologic analysis of bronchoalveolar lavage (BAL) fluid is used for lung cancer diagnosis. We describe a patient with a history of rectal carcinoma who presented with a new lung mass. BAL was performed, with positron emission tomography-computed tomography the following day. There was mildly increased fluoro-deoxy-D-glucose uptake in areas of the lung parenchyma with new ground-glass opacification. This created ambiguity in staging, clarified 2 weeks later by a computed tomography showing complete resolution of the ground-glass opacity. Clinicians should be aware that BAL may cause increased pulmonary fluoro-deoxy-D-glucose uptake, making accurate radiologic interpretation problematic. We suggest that to optimize positron emission tomography-computed tomography, studies should not be performed within 24 hours of BAL.

  7. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  8. Single photon emission computerized tomography (SPECT)

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as 123 I and 99 Tc m that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  9. Single photon emission computerized tomography (SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Ganatra, R D

    1993-12-31

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as {sup 123}I and {sup 99}Tc{sup m} that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  10. Computed chest tomography in rats with pulmonary damage due to microembolism

    Energy Technology Data Exchange (ETDEWEB)

    Wegener, T.; Wegenius, G.; Hemmingsson, A.; Jung, B.; Saldeen, T.

    Computed chest tomography was performed in 13 rats with pulmonary damage due to microembolism, caused by injection of thrombin (500 NIH/kg body weight) and tranexamic acid, a fibrinolytic inhibitor (200 mg/kg body weight), and in 9 control rats. The purpose of the investigation was to perform attenuation measurements at two levels of the right lung, each with three regions of interest (anterior, mid and posterior). Alterations in attenuation, compared with controls, were correlated with lung weight. Compared with controls, the attenuation was significantly increased in the anterior and posterior regions at both levels in animals with pulmonary damage, but not in the mid regions. There was a statistically significant correlation between increasing attenuation and increasing lung weight. A significant difference was found between damaged and control lungs regarding the microscopic grade of interstitial oedema, alveolar oedema and fibrin. Histograms of attenuation values in computed tomograms might be of value in detecting alveolar oedema. It is concluded that computed chest tomography is a good method for detection pulmonary oedema at an early stage of experimental microembolism in the rat.

  11. Computed chest tomography in rats with pulmonary damage due to microembolism

    International Nuclear Information System (INIS)

    Wegener, T.; Wegenius, G.; Hemmingsson, A.; Jung, B.; Saldeen, T.; Uppsala Univ.; Uppsala Univ.; Uppsala Univ.

    1986-01-01

    Computed chest tomography was performed in 13 rats with pulmonary damage due to microembolism, caused by injection of thrombin (500 NIH/kg body weight) and tranexamic acid, a fibrinolytic inhibitor (200 mg/kg body weight), and in 9 control rats. The purpose of the investigation was to perform attenuation measurements at two levels of the right lung, each with three regions of interest (anterior, mid and posterior). Alterations in attenuation, compared with controls, were correlated with lung weight. Compared with controls, the attenuation was significantly increased in the anterior and posterior regions at both levels in animals with pulmonary damage, but not in the mid regions. There was a statistically significant correlation between increasing attenuation and increasing lung weight. A significant difference was found between damaged and control lungs regarding the microscopic grade of interstitial oedema, alveolar oedema and fibrin. Histograms of attenuation values in computed tomograms might be of value in detecting alveolar oedema. It is concluded that computed chest tomography is a good method for detection pulmonary oedema at an early stage of experimental microembolism in the rat. (orig.)

  12. Magnetic resonance tomography - a possibility for noninvasive meniscus diagnosis. Pt. 1

    International Nuclear Information System (INIS)

    Wacker, F.; Koenig, H.; Sell, S.

    1989-01-01

    Meniscus tears were experimentally produced by surgery in 5 pigs. They were identified via MR tomography with the selected routine sequence (SE: TR 1600, TE 22/80msec, SD 3 mm) independent of position, orientation and severity. The best imaging was obtained between the 2nd and 8th weeks after the operation in the sagittal plane. Subsequently the contrast and with it simultaneously the delineation between intact fibrous cartilage and rupture cleft decreased; this could be observed in sequences weighted according to proton density and T2 in different degrees of intensity. Parallel to this a trial to induce degeneration in the meniscus tissue resulted 8 weeks after the operation in central, signal-intensive zones in the menisci. No success was achieved in trying to improve imaging of the pathological changes by means of intraarticular injections of Gd-DTPA; this was tried out at various points of time. Besides enabling the imaging of lesions of the fibrous cartilage as a matter of principle, MR tomography can also give limited information on the age of a meniscus tear. (orig.) [de

  13. Magnetic resonance electrical impedance tomography (MREIT): conductivity and current density imaging

    International Nuclear Information System (INIS)

    Seo, Jin Keun; Kwon, Ohin; Woo, Eung Je

    2005-01-01

    This paper reviews the latest impedance imaging technique called Magnetic Resonance Electrical Impedance Tomography (MREIT) providing information on electrical conductivity and current density distributions inside an electrically conducting domain such as the human body. The motivation for this research is explained by discussing conductivity changes related with physiological and pathological events, electromagnetic source imaging and electromagnetic stimulations. We briefly summarize the related technique of Electrical Impedance Tomography (EIT) that deals with cross-sectional image reconstructions of conductivity distributions from boundary measurements of current-voltage data. Noting that EIT suffers from the ill-posed nature of the corresponding inverse problem, we introduce MREIT as a new conductivity imaging modality providing images with better spatial resolution and accuracy. MREIT utilizes internal information on the induced magnetic field in addition to the boundary current-voltage measurements to produce three-dimensional images of conductivity and current density distributions. Mathematical theory, algorithms, and experimental methods of current MREIT research are described. With numerous potential applications in mind, future research directions in MREIT are proposed

  14. Estudos quantitativos em educação Quantitative studies in education

    Directory of Open Access Journals (Sweden)

    Bernardete A. Gatti

    2004-04-01

    Full Text Available O artigo trata de estudos em educação, realizados no Brasil nas últimas três décadas, utilizando abordagens quantitativas. Para a seleção dos trabalhos a serem tratados fez-se um levantamento em todos os números publicados de 1970 para cá dos seguintes periódicos: Revista Brasileira de Estudos Pedagógicos (Inep/MEC, Cadernos de Pesquisa (Fundação Carlos Chagas, Educação e Realidade (UFRS, Educação e Sociedade (Cedes/Unicamp, Revista Brasileira de Educação (ANPEd, Estudos em Avaliação Educacional (Fundação Carlos Chagas, Ensaio (Fundação Cesgranrio. Algumas fontes bibliográficas foram consultadas na busca de outros estudos. Ressalta-se a importância de perspectivas teóricas para o delineamento e desenvolvimento dos estudos, que devem ser colocados no contexto de uma reflexão educacional e de problematização, bem como, assinala a necessidade de adequação das escolhas dos tipos de análise a serem empregados. Discute a pouca tradição de realização de trabalhos em educação com as metodologias quantitativas no Brasil e o possível papel da quantificação na pesquisa educacional. Mostra algumas contribuições desses trabalhos à reflexão no campo da Educação, bem como para a fundamentação de algumas perspectivas críticas. Essas contribuições foram tratadas por temas, a saber: analfabetismo, percurso escolar e fracasso escolar; fluxo escolar/análise de coortes; letramento; políticas e educação básica; financiamento da educação/municipalização; fatores sociais e educação; jovens e educação; avaliação educacional; temas variados.The article refers to studies in education carried out in Brazil during the last three decades using quantitative approaches. The selection of the works to be examined was based on a survey of all issues published since 1970 by the following journals: Revista Brasileira de Estudos Pedagógicos (Inep/MEC, Cadernos de Pesquisa (Fundação Carlos Chagas, Educação e

  15. Quality control and radioprotection in dental cone beam computed tomography - case study

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Ligiane C.N.; Ferreira, Nadya M.P.D., E-mail: lnadya@ime.eb.br [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    The radiological protection in medical and odontologic radiology follows The Order (Portaria) 453/98 of the Ministry of Health, which presents the minimum set of tests for the constancy X-ray equipment. These tests follow the procedures set forth in the Resolution no. 64, the National Agency for Sanitary Vigilance. This work aims to show a study on dental cone beam computed tomography (CBCT), evaluating the physical parameters that influence the performance and image quality and presenting the appropriate tests to this new system. The authors analyzed the tests specific for computed tomography (CT) of the Resolution no. 64, feasibility assessment of them and if their interpretations are compatible with CBCT. Once determined if testing is feasible, compare with those presented in the manual provided by the equipment manufacturer. The CT scanner used was the Mini-Cat Tomography Scanner Xoran Technologies of KAVO. In the study it was verified that four tests could be reproduced in CBCT: noise, accuracy and uniformity in the number of CT of water and spatial resolution. Considering experimental data, the methodology and tolerance of manufacturer for the first two tests were more appropriate. For the uniformity test of the CT number, we recommend using the phantom quality control. Three new tests were suggested to be made in the quality control of the Cone Beam: linearity, artifacts and alignment of the beam. (author)

  16. Quality control and radioprotection in dental cone beam computed tomography - case study

    International Nuclear Information System (INIS)

    Rodrigues, Ligiane C.N.; Ferreira, Nadya M.P.D.

    2011-01-01

    The radiological protection in medical and odontologic radiology follows The Order (Portaria) 453/98 of the Ministry of Health, which presents the minimum set of tests for the constancy X-ray equipment. These tests follow the procedures set forth in the Resolution no. 64, the National Agency for Sanitary Vigilance. This work aims to show a study on dental cone beam computed tomography (CBCT), evaluating the physical parameters that influence the performance and image quality and presenting the appropriate tests to this new system. The authors analyzed the tests specific for computed tomography (CT) of the Resolution no. 64, feasibility assessment of them and if their interpretations are compatible with CBCT. Once determined if testing is feasible, compare with those presented in the manual provided by the equipment manufacturer. The CT scanner used was the Mini-Cat Tomography Scanner Xoran Technologies of KAVO. In the study it was verified that four tests could be reproduced in CBCT: noise, accuracy and uniformity in the number of CT of water and spatial resolution. Considering experimental data, the methodology and tolerance of manufacturer for the first two tests were more appropriate. For the uniformity test of the CT number, we recommend using the phantom quality control. Three new tests were suggested to be made in the quality control of the Cone Beam: linearity, artifacts and alignment of the beam. (author)

  17. Digital multilayer tomography

    International Nuclear Information System (INIS)

    Dueber, C.; Klose, K.J.; Thelen, M.

    1991-01-01

    With digital multilayer tomography a sequence of projection images is recorded by an image intensifier television system and stored as digital data during a linear run of a layer sequence. Using this data record, tomograms of the examined body region can be computed for any layer thickness by shifts and superimposition of the single projections later at a digital workstation. The qualities of digital and conventional tomograms are basically comparable. A drawback of digital tomography is its lower local resolution (512 x 512 image matrix), advantages are a lower radiation exposure, a shorter patient examination time, and the facilities of digital image processing (later processing, archive setup, transmission). (orig.) [de

  18. F-18-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Appearance of Extramedullary Hematopoesis in a Case of Primary Myelofibrosis

    Science.gov (United States)

    Mukherjee, Anirban; Bal, Chandrasekhar; Tripathi, Madhavi; Das, Chandan Jyoti; Shamim, Shamim Ahmed

    2017-01-01

    A 44-year-old female with known primary myelofibrosis presented with shortness of breath. High Resolution Computed Tomography thorax revealed large heterogeneously enhancing extraparenchymal soft tissue density mass involving bilateral lung fields. F-18-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography revealed mildly FDG avid soft tissue density mass with specks of calcification involving bilateral lung fields, liver, and spleen. Subsequent histopathologic evaluation from the right lung mass was suggestive of extramedullary hematopoesis. PMID:28533647

  19. EDITORIAL: Industrial Process Tomography

    Science.gov (United States)

    Anton Johansen, Geir; Wang, Mi

    2008-09-01

    There has been tremendous development within measurement science and technology over the past couple of decades. New sensor technologies and compact versatile signal recovery electronics are continuously expanding the limits of what can be measured and the accuracy with which this can be done. Miniaturization of sensors and the use of nanotechnology push these limits further. Also, thanks to powerful and cost-effective computer systems, sophisticated measurement and reconstruction algorithms previously only accessible in advanced laboratories are now available for in situ online measurement systems. The process industries increasingly require more process-related information, motivated by key issues such as improved process control, process utilization and process yields, ultimately driven by cost-effectiveness, quality assurance, environmental and safety demands. Industrial process tomography methods have taken advantage of the general progress in measurement science, and aim at providing more information, both quantitatively and qualitatively, on multiphase systems and their dynamics. The typical approach for such systems has been to carry out one local or bulk measurement and assume that this is representative of the whole system. In some cases, this is sufficient. However, there are many complex systems where the component distribution varies continuously and often unpredictably in space and time. The foundation of industrial tomography is to conduct several measurements around the periphery of a multiphase process, and use these measurements to unravel the cross-sectional distribution of the process components in time and space. This information is used in the design and optimization of industrial processes and process equipment, and also to improve the accuracy of multiphase system measurements in general. In this issue we are proud to present a selection of the 145 papers presented at the 5th World Congress on Industrial Process Tomography in Bergen

  20. Treinamento auditivo nas alterações do processamento auditivo: estudo de caso

    OpenAIRE

    Stroiek,Susan; Quevedo,Lenita da Silva; Kieling,Carla Hernandez; Battezini,Ana Carolina Lago

    2015-01-01

    O objetivo deste estudo é verificar a eficácia de um programa de Treinamento Auditivo comparando o desempenho inicial, nos testes de avaliação do processamento auditivo, com o desempenho após o treinamento auditivo. Para este estudo de caso, desenvolvido na clínica de Fonoaudiologia da Universidade de Passo Fundo, foi selecionado um indivíduo que apresentava alterações de linguagem, queixas compatíveis com alterações de processamento auditivo, avaliação audiológica básica normal e avaliação d...

  1. Estudo de mercado: "A satisfação dos franchisados em Portugal"

    OpenAIRE

    Fialho, Maria Cristina Grilo

    2013-01-01

    Este relatório de estágio foi realizado no âmbito do Mestrado em Matemática e Aplicações, com especialização em Estatística e Investigação Operacional, da Universidade de Aveiro, e o estágio foi realizado no GEMEO (Gabinete de Estudos de Mercado e Opinião do IPAM). Foram desenvolvidas várias atividades relacionadas com os Estudos de Mercado, e uma dessas atividades é sobre o Franchising, onde se pretende avaliar o perfil e satisfação do Franchisado em Portugal. Para isso, fo...

  2. UM ESTUDO BIBLIOMÉTRICO SOBRE ALIANÇAS, INOVAÇÃO E DESEMPENHO

    OpenAIRE

    Fábio de Oliveira Paula; Luiz Fernando de Paris Caldas; Jorge Ferreira da Silva

    2016-01-01

    O objetivo deste artigo é analisar os trabalhos mais relevantes para o estudo do impacto das alianças para inovação no desempenho das firmas e identificar os temas mais relevantes que formam o arcabouço teórico dessa área. A pesquisa analisou, a partir de um corte longitudinal compreendendo três períodos de seis anos entre 1997 e 2014, a evolução dos temas e trabalhos, identificando os que mantiveram relevância e em torno de quais temas os estudos convergiram. A pesquisa foi realizada aplican...

  3. 3D electrical conductivity tomography of volcanoes

    Science.gov (United States)

    Soueid Ahmed, A.; Revil, A.; Byrdina, S.; Coperey, A.; Gailler, L.; Grobbe, N.; Viveiros, F.; Silva, C.; Jougnot, D.; Ghorbani, A.; Hogg, C.; Kiyan, D.; Rath, V.; Heap, M. J.; Grandis, H.; Humaida, H.

    2018-05-01

    Electrical conductivity tomography is a well-established galvanometric method for imaging the subsurface electrical conductivity distribution. We characterize the conductivity distribution of a set of volcanic structures that are different in terms of activity and morphology. For that purpose, we developed a large-scale inversion code named ECT-3D aimed at handling complex topographical effects like those encountered in volcanic areas. In addition, ECT-3D offers the possibility of using as input data the two components of the electrical field recorded at independent stations. Without prior information, a Gauss-Newton method with roughness constraints is used to solve the inverse problem. The roughening operator used to impose constraints is computed on unstructured tetrahedral elements to map complex geometries. We first benchmark ECT-3D on two synthetic tests. A first test using the topography of Mt. St Helens volcano (Washington, USA) demonstrates that we can successfully reconstruct the electrical conductivity field of an edifice marked by a strong topography and strong variations in the resistivity distribution. A second case study is used to demonstrate the versatility of the code in using the two components of the electrical field recorded on independent stations along the ground surface. Then, we apply our code to real data sets recorded at (i) a thermally active area of Yellowstone caldera (Wyoming, USA), (ii) a monogenetic dome on Furnas volcano (the Azores, Portugal), and (iii) the upper portion of the caldera of Kīlauea (Hawai'i, USA). The tomographies reveal some of the major structures of these volcanoes as well as identifying alteration associated with high surface conductivities. We also review the petrophysics underlying the interpretation of the electrical conductivity of fresh and altered volcanic rocks and molten rocks to show that electrical conductivity tomography cannot be used as a stand-alone technique due to the non-uniqueness in

  4. Hardwares e sistemas multiagente: um estudo sobre arquiteturas híbridas

    Directory of Open Access Journals (Sweden)

    Rafhael Rodrigues Cunha

    2015-05-01

    Full Text Available Este artigo apresenta três estudos de caso sobre a aplicabilidade de arquiteturas de hardware reconfiguráveis, como FPGA, voltadas à utilização em sistemas multiagentes. Feita uma análise visando à elucidação dos resultados e das contribuições que os estudos proporcionaram aos autores, observa-se que o desenvolvimento de sistemas inteligentes depende cada vez mais de uma programação que explore o hardware ao máximo. Esse desfecho torna o uso de hardwares reconfiguráveis o mais aconselhável quando problemas computacionais complexos demandam respostas rápidas e eficientes, como nos casos estudados.

  5. Study of computerized tomography using neutron beam

    International Nuclear Information System (INIS)

    Pereira, W.W.

    1991-05-01

    This paper aims to demonstrate the advantages, shortcomings and complementaries of a tomography development using neutrons over the one employing gamma rays in the context of their applications to non destructive essays. A simulated experimental study was performed in order to compare the two aforementioned tomographic procedures as applied to some materials. These materials were chosen for their clear advantages and complementaries as, for instance, aluminium, iron, plastic and aluminium hydroxide. In this work two tomographic systems, are employed both with parallel beams. The first with a gamma radiation source (Caesium-137), with an energy of 662 KeV and an activity of 3,9 x 10 9 Bq (100 mCi) and the second one employing a neutron source, the Argonaut Reactor of the Instituto de Engenharia Nuclear, IEN/CNEN, from where the thermal neutron beam of about 10 5 n/(cm.s) was obtained. It is possible to conclude from the simulated and experimental results, by means of image analysis and distortion measurements, that for a given material the adequate radiation and its energy may be chosen so as to better characterize it. (author)

  6. Recurrent ovarian endodermal sinus tumor: demonstration by computed tomography, magnetic resonance imaging, and positron emission tomography

    International Nuclear Information System (INIS)

    Romero, J.A.; Kim, E.E.; Tresukosol, D.; Kudelka, A.P.; Edwards, C.L.; Kavanagh, J.J.

    1995-01-01

    We report a case of recurrent endodermal sinus tumor of the ovary that was identified and/or clearly depicted by computed tomography, magnetic resonance imaging, and positron emission tomography. The potential roles of various imaging modalities in the detection of recurrent endodermal sinus tumor are discussed. (orig.)

  7. Influência da irrigação de soluções nutricionais no colo excluso de trânsito intestinal: estudo experimental em ratos Influence of irrigation of nutritional solutions in the colon excluded of fecal stream: experimental study in rats

    Directory of Open Access Journals (Sweden)

    Carlos Guilherme Giazzi Nassri

    2008-09-01

    Full Text Available A colite por exclusão é descrita como processo inflamatório que ocorre nos segmentos colorretais desprovidos do trânsito fecal. A deficiência dos ácidos graxos de cadeia curta vem sendo considerada como principal fator causal. OBJETIVO: O objetivo do presente estudo foi avaliar, em modelo experimental de colite de exclusão, a importância da irrigação do segmento desprovido de trânsito com soluções nutricionais na prevenção e tratamento do processo inflamatório. MÉTODO: Foram utilizados trinta ratos Wistar, machos, com peso inicial variando entre 350 e 500 gramas, submetidos à derivação do trânsito intestinal através da realização de colostomia proximal e fístula mucosa distal. Os animais foram divididos em três grupos de 10 animais segundo a irrigação do segmento excluso de trânsito ter sido realizada, empregando-se: Grupo SF: solução fisiológica a 0,9%; Grupo GH: solução de glicose a 50%; e Grupo AG: solução de ácidos graxos de cadeia curta. Em todos os animais, a irrigação do colo excluso foi realizada em intervalos de quatro dias sendo sacrificados sempre no 21º pós-operatório. Os fragmentos removidos dos segmentos intestinais foram corados pelas técnicas da hematoxilina-eosina e tricrômio de Masson. As variáveis histológicas estudadas foram: espessura da túnica mucosa, congestão vascular; infiltrado inflamatório e a deposição de colágeno. Os resultados encontrados foram submetidos a estudo estatístico considerando nível de significância de 5% (pDiversion colitis is described as an inflammatory process that occurs in the colorectal segments excluded of the fecal stream. The deficiency of the short-chain fatty acids inside of intestinal lumen was considered the main etiologic factor. AIM: The aim of the present study was valued, in experimental model of diversion colitis, the importance of the irrigation of the segment without fecal stream with nutritional solutions in prevention and

  8. Reflection tomography from pre-stack migrated images; Tomographie de reflexion a partir des images migrees avant addition

    Energy Technology Data Exchange (ETDEWEB)

    Adler, F

    1996-10-29

    The application of reflection tomography to data from complex geological structures is very interesting in the hydrocarbons exploration. Indeed, it contributes to localize the hydrocarbons potential traps. The used reflection tomography method is faced with two major difficulties. Travel time picking is difficult or impossible in seismic time sections. The processing of multiple arrival travel times needs an adequate formulation of reflection tomography. In order to solve the first problem, we adopt the approach of the SMART (Sequential Migration Aided Reflection Tomography) method which is an original method for the implementation of migration velocity analysis. The velocity model is automatically calculated by reflection tomography. The kinematic data set for reflection tomography is constructed from pre-stack depth-migrated images that are interpreted in the chosen migration configuration. For the implementation of the SMART method in the common-offset domain, we propose an original formulation of reflection tomography that takes multiple arrival travel times, which are calculated from common-offset migrated images, into account. In this new formulation, we look for a model such that a modelling, which consists in shooting in this model from the source locations with some ray parameters at the source, matches some emergence conditions: for each offset, the rays emerge at the receiver locations (given by the offset) with the same travel times and the same travel time slopes as observed in the associated common-offset section. These conditions constitute the kinematic data set for tomographic inversion. The common-offset travel time slope is the difference between the ray parameter at the receiver and the ray parameter at the source. Therefore, the ray parameter at the source is an unknown and has to be determined together with the model parameters during inversion. (author)

  9. OS SISTEMAS AGROFLORESTAIS COMO ALTERNATIVA ECONÔMICA EM PEQUENAS PROPRIEDADES RURAIS: ESTUDO DE CASO

    Directory of Open Access Journals (Sweden)

    Mário Jorge Campos dos Santos

    2002-05-01

    Full Text Available Os Sistemas Agroflorestais (SAFs constituem-se em uma alternativa de uso da terra para aliar a estabilidade do ecossistema visando à eficiência e otimização de recursos naturais na produção de forma integrada e sustentada. O objetivo deste estudo de caso foi avaliar a viabilidade econômica de um sistema agroflorestal localizado na região do Pontal do Paranapanema. O SAF em estudo é formada por espécies agrícolas: milho (Zea maiz, feijão guandu (Cajanus cajan, carioquinha, (Vigna unguiculata, preto (Phaseolus vulgaris e mandioca (Manihot esculenta com espécies florestais: Eucalyptus citriodora e Eucalyptus camaldulensis. A rentabilidade econômica do sistema foi mensurada, utilizando Valor Presente Líquido (VPL, Razão Benefício/Custo (RB/C para as culturas agrícolas anuais e Valor Esperado da terra (VET para os componentes madeireiros. Para tais cálculos foi escolhida uma taxa de desconto de 6%. O estudo demonstrou que o sistema agroflorestal apresentou rentabilidade econômica positiva, e que podem ser adotados por pequenos produtores. Assim, pode-se concluir que os sistemas agroflorestais são economicamente viáveis para pequenos produtores rurais trabalhando nas mesmas condições apresentadas neste estudo.

  10. Estudo bibliométrico do descritor “Ergonomia” na base LISA

    Directory of Open Access Journals (Sweden)

    Eliana Maria dos Santos Bahia

    2011-03-01

    Full Text Available Objetivo: O estudo analisa a produção científica sobre ergonomia utilizando a base de dados Library and Information Science Abstracts (LISA. A base de dados LISA, iniciada em 1969, mantém sua cobertura temática na área de Biblioteconomia e Ciência da Informação.Método: No estudo utilizou-se o método da bibliometria aplicada para verificar a produção científica indexada.Resultados: Entre os resultados da busca de termos indexados na base de dados LISA, encontraram-se 503 artigos com o termo “Ergonomic”; 352 artigos, com a expressão “Design”; 111 artigos com o descritor “Systems”; 110 artigos com o termo “Work”; e , 98 artigos com o termo “Evaluation”. Dentre os 34 títulos de periódicos, 4 títulos cobrem 79% dos artigos que tratam sobre Ergonomia na base LISA. Os demais 30 títulos de periódicos cobrem 21% dos artigos indexados sob essa temática.Conclusões: O presente estudo bibliométrico oferece possibilita um panorama de como a ergonomia é percebida na área da Biblioteconomia e Ciência da Informação.

  11. Experimental results supporting the concept of one-sided muon tomography

    Energy Technology Data Exchange (ETDEWEB)

    Boniface, K., E-mail: bonifak@mcmaster.ca [McMaster University, Hamilton, ON (Canada); Jonkmans, G. [Canadian Nuclear Laboratories, Chalk River, ON (Canada); Buijs, A. [McMaster University, Hamilton, ON (Canada); Erlandson, A.; Livingstone, S. [Canadian Nuclear Laboratories, Chalk River, ON (Canada)

    2015-07-01

    Naturally occurring cosmic-ray muons have been shown to exhibit properties ideal for imaging the interior of structures containing material of high density and atomic number. The commonly used method for 3D imaging requires two modules of detection in order to measure muon scattering. This paper provides experimental results for a novel 3D imaging method that uses a reconstruction algorithm common to medical imaging and only one module of detection in order to measure the attenuation of the muon flux at several angles of rotation around a structure. (author)

  12. 21 CFR 892.1200 - Emission computed tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emission computed tomography system. 892.1200... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1200 Emission computed tomography system. (a) Identification. An emission computed tomography system is a device intended to detect the...

  13. Full characterization of a three-photon Greenberger-Horne-Zeilinger state using quantum state tomography.

    Science.gov (United States)

    Resch, K J; Walther, P; Zeilinger, A

    2005-02-25

    We have performed the first experimental tomographic reconstruction of a three-photon polarization state. Quantum state tomography is a powerful tool for fully describing the density matrix of a quantum system. We measured 64 three-photon polarization correlations and used a "maximum-likelihood" reconstruction method to reconstruct the Greenberger-Horne-Zeilinger state. The entanglement class has been characterized using an entanglement witness operator and the maximum predicted values for the Mermin inequality were extracted.

  14. Efficacy of 3D-positron emission tomography/computed tomography for upper abdomen.

    Science.gov (United States)

    Murakami, Koji; Nakahara, Tadaki

    2014-04-01

    Recent advancement in computed tomography (CT) enables us to obtain high spatial resolution image and made it possible to construct extensive high-definition three-dimensional (3D) images. But a lack of contrast resolution in CT alone is still remained problem. Meanwhile, as fluorodeoxyglucose-positron emission tomography (PET) can visualize tumors in high contrast, we can create 3D images fusing the accumulation in tumors on PET/CT images. Such images can play the role of a "map of body" which makes it easy to understand the anatomical information before surgery. We also try to evaluate segmental liver function by using PET/CT fusion images. By using (11) C-methionine PET/contrast-enhanced CT, superior image quality compared to single photon emission computed tomography/CT can be obtained. CT, especially with contrast enhancement for obtaining anatomical imaging information plus PET for obtaining functional imaging information is a highly compatible combination, and adding these two types information will further increase clinical usefulness. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  15. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    International Nuclear Information System (INIS)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M.

    2000-01-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  16. Contrast-enhanced fluorodeoxyglucose positron emission tomography/contrast-enhanced computed tomography in mediastinal T-cell lymphoma with superior vena cava syndrome

    International Nuclear Information System (INIS)

    Santhosh, Sampath; Gorla, Arun Kumar Reddy; Bhattacharya, Anish; Varma, Subhash Chander; Mittal, Bhagwant Rai

    2016-01-01

    Positron emission tomography-computed tomography (PET/CT) is a routine investigation for the staging of lymphomas. Contrast-enhanced computed tomography is mandatory whenever parenchymal lesions, especially in the liver and spleen are suspected. We report a rare case of primary mediastinal T-cell lymphoma evaluated with contrast-enhanced PET/CT that showed features of superior vena cava syndrome

  17. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  18. Evaluation of microfluidic channels with optical coherence tomography

    KAUST Repository

    Czajkowski, J.; Prykä ri, T.; Alarousu, E.; Lauri, J.; Myllylä , R.

    2010-01-01

    Application of time domain, ultra high resolution optical coherence tomography (UHR-OCT) in evaluation of microfluidic channels is demonstrated. Presented study was done using experimental UHR-OCT device based on a Kerr-lens mode locked Ti:sapphire femtosecond laser, a photonic crystal fibre and modified, free-space Michelson interferometer. To show potential of the technique, microfluidic chip fabricated by VTT Center for Printed Intelligence (Oulu, Finland) was measured. Ability for full volumetric reconstruction in non-contact manner enabled complete characterization of closed entity of a microfluidic channel without contamination and harm for the sample. Measurement, occurring problems, and methods of postprocessing for raw data are described. Results present completely resolved physical structure of the channel, its spatial dimensions, draft angles and evaluation of lamination quality.

  19. Evaluation of microfluidic channels with optical coherence tomography

    KAUST Repository

    Czajkowski, J.

    2010-06-25

    Application of time domain, ultra high resolution optical coherence tomography (UHR-OCT) in evaluation of microfluidic channels is demonstrated. Presented study was done using experimental UHR-OCT device based on a Kerr-lens mode locked Ti:sapphire femtosecond laser, a photonic crystal fibre and modified, free-space Michelson interferometer. To show potential of the technique, microfluidic chip fabricated by VTT Center for Printed Intelligence (Oulu, Finland) was measured. Ability for full volumetric reconstruction in non-contact manner enabled complete characterization of closed entity of a microfluidic channel without contamination and harm for the sample. Measurement, occurring problems, and methods of postprocessing for raw data are described. Results present completely resolved physical structure of the channel, its spatial dimensions, draft angles and evaluation of lamination quality.

  20. Evaluation of microfluidic channels with optical coherence tomography

    Science.gov (United States)

    Czajkowski, J.; Prykäri, T.; Alarousu, E.; Lauri, J.; Myllylä, R.

    2010-11-01

    Application of time domain, ultra high resolution optical coherence tomography (UHR-OCT) in evaluation of microfluidic channels is demonstrated. Presented study was done using experimental UHR-OCT device based on a Kerr-lens mode locked Ti:sapphire femtosecond laser, a photonic crystal fibre and modified, free-space Michelson interferometer. To show potential of the technique, microfluidic chip fabricated by VTT Center for Printed Intelligence (Oulu, Finland) was measured. Ability for full volumetric reconstruction in non-contact manner enabled complete characterization of closed entity of a microfluidic channel without contamination and harm for the sample. Measurement, occurring problems, and methods of postprocessing for raw data are described. Results present completely resolved physical structure of the channel, its spatial dimensions, draft angles and evaluation of lamination quality.

  1. Estudo das características da oclusão na dentição decídua e na mista e fatores associados

    OpenAIRE

    Costa, Catiara Terra da

    2013-01-01

    Conhecer as características oclusais das dentições decídua e mista, seu desenvolvimento, alterações e possíveis fatores influentes é importante para a prevenção e interceptação das maloclusões, tornando-se de grande valor epidemiológico. Para isto, estudos longitudinais são apropriados, pois observam a mesma população em momentos temporais diferentes. Este estudo foi constituído de duas partes: estudo transversal e estudo longitudinal. O estudo transversal investigou a influência dos fatores ...

  2. How accurately can 21cm tomography constrain cosmology?

    Science.gov (United States)

    Mao, Yi; Tegmark, Max; McQuinn, Matthew; Zaldarriaga, Matias; Zahn, Oliver

    2008-07-01

    There is growing interest in using 3-dimensional neutral hydrogen mapping with the redshifted 21 cm line as a cosmological probe. However, its utility depends on many assumptions. To aid experimental planning and design, we quantify how the precision with which cosmological parameters can be measured depends on a broad range of assumptions, focusing on the 21 cm signal from 6noise, to uncertainties in the reionization history, and to the level of contamination from astrophysical foregrounds. We derive simple analytic estimates for how various assumptions affect an experiment’s sensitivity, and we find that the modeling of reionization is the most important, followed by the array layout. We present an accurate yet robust method for measuring cosmological parameters that exploits the fact that the ionization power spectra are rather smooth functions that can be accurately fit by 7 phenomenological parameters. We find that for future experiments, marginalizing over these nuisance parameters may provide constraints almost as tight on the cosmology as if 21 cm tomography measured the matter power spectrum directly. A future square kilometer array optimized for 21 cm tomography could improve the sensitivity to spatial curvature and neutrino masses by up to 2 orders of magnitude, to ΔΩk≈0.0002 and Δmν≈0.007eV, and give a 4σ detection of the spectral index running predicted by the simplest inflation models.

  3. Promising role of single photon emission computed tomography/computed tomography in Meckel's scan

    International Nuclear Information System (INIS)

    Jain, Anurag; Chauhan, MS; Pandit, AG; Kumar, Rajeev; Sharma, Amit

    2012-01-01

    Meckel's scan is a common procedure performed in nuclear medicine. Single-photon emission computed tomography/computed tomography (SPECT/CT) in a suspected case of heterotopic location of gastric mucosa can increase the accuracy of its anatomic localization. We present two suspected cases of Meckel's diverticulum in, which SPECT/CT co-registration has helped in better localization of the pathology

  4. Phase-Space Tomography of Giant Pulses in Storage Ring FEL Theory and Experiment

    CERN Document Server

    Chalut, K

    2005-01-01

    The use of giant pulses in storage ring FEL provides for high peak power at the fundamental wavelength and for effective generating of high VUV harmonics. This process is accompanied by a complex nonlinear dynamics of electron beam, which cannot be described by simple models. In this paper we compare the results of numerical simulations, performed by self-consistent #uvfel code, with experimental observations of electron beam evolution in the longitudinal phase space. The evolution of the electron beam distribution was obtained from the images recorded by dual-sweep streak-camera. The giant pulse process occurs on a short fast time scale compared with synchrotron oscillation period, which make standard methods of tomography inapplicable. We had developed a novel method of reconstruction, an SVD-Based Phase-Space Tomography, which allows to reconstruct phase space distribution from as few as two e-bunch profiles separated by about 3 degrees of rotation in the phase space. This technique played critical role in...

  5. An update in proton probe tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sakellariou, A.; Cholewa, M.; Saint, A.; Legge, G.L.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Howard, J. [Australian National Univ., Canberra, ACT (Australia). Research School of Physical Sciences

    1996-12-31

    The analysis of scanning transmission ion microscopy (STIM) tomography data is improved. The volumetric density information is obtained directly from an iterative convolution and back-projection (BFP) reconstruction method. The iterative method allows the effects of stopping-power to be incorporated easily. One draw back is that a priori constituency information is required for the iterative method to work However, this is of no concern because the iterative method was designed with PIXE tomography in mind. In this light, the a priori information will be obtained as the zeroth iteration of a PIXE tomography iterative reconstruction method. 4 refs., 1 tab., 4 figs.

  6. An update in proton probe tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sakellariou, A; Cholewa, M; Saint, A; Legge, G L.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Howard, J [Australian National Univ., Canberra, ACT (Australia). Research School of Physical Sciences

    1997-12-31

    The analysis of scanning transmission ion microscopy (STIM) tomography data is improved. The volumetric density information is obtained directly from an iterative convolution and back-projection (BFP) reconstruction method. The iterative method allows the effects of stopping-power to be incorporated easily. One draw back is that a priori constituency information is required for the iterative method to work However, this is of no concern because the iterative method was designed with PIXE tomography in mind. In this light, the a priori information will be obtained as the zeroth iteration of a PIXE tomography iterative reconstruction method. 4 refs., 1 tab., 4 figs.

  7. Enfermeiros e clientela com bulimia e anorexia: estudo de caso

    Directory of Open Access Journals (Sweden)

    Claudia Regina Carvalho Martins

    2012-06-01

    Full Text Available Investigação que objetivou identificar a interação de enfermeiros e clientes portadores de bulimia e anorexia. Utilizamos o estudo de caso como recurso, para o qual coletamos dados de prontuários e fizemos entrevistas com oito de quatorze enfermeiros, que foram nossos sujeitos-objeto. De acordo com os enfermeiros, os clientes se isolavam do mundo, vivendo num mundo sem fome e de espelhos que refletiam um corpo sempre acima do "peso ideal"; eram pessoas solitárias, que perderam o brilho pessoal, emitindo sinais de que podiam extinguir a vida deles a qualquer momento. Com o estudo, foi possível identificar a maneira pela qual os enfermeiros interagiam e percebiam os clientes e, em decorrência disso, explicitamos uma prática de cuidar peculiar na enfermagem.

  8. Reinforced concrete tomography

    International Nuclear Information System (INIS)

    Mariscotti, M.A.J.; Morixe, M.; Tarela, P.A.; Thieberger, P.

    1997-01-01

    In this paper we describe the technique of reinforced concrete tomography, its historical background, recent technological developments and main applications. Gamma radiation sensitive plates are imprinted with radiation going through the concrete sample under study, and then processed to reveal the presence of reinforcement and defects in the material density. The three dimensional reconstruction, or tomography, of the reinforcement out of a single gammagraphy is an original development alternative to conventional methods. Re-bar diameters and positions may be determined with an accuracy of ± 1 mm 0.5-1 cm, respectively. The non-destructive character of this technique makes it particularly attractive in cases of inhabited buildings and diagnoses of balconies. (author) [es

  9. MAPEAMENTO GEOLITERÁRIO: UMA PROPOSTA METODOLÓGICA PARA OS ESTUDOS GEOGRÁFICOS

    Directory of Open Access Journals (Sweden)

    Walter Luiz Jardim Rodrigues

    2016-06-01

    Full Text Available Os romances são produções literárias que abrigam em suas páginas, variadas possibilidades de estudos. Embora pouco explorados neste sentido, seus estudos podem ser muito úteis não somente para linha de pesquisa da Geografia e Literatura, mas para diversos ramos do conhecimento como a percepção ambiental, urbanismo, história, economia e entre outros. Neste sentido, procura-se contribuir com uma abordagem metodológica para apreensão do espaço geográfico através de obras literárias, e nesse estudo, a análise do espaço geográfico da cidade de Belém do Pará da década de 1920, descrita no romance “Belém do Grão-Pará” de Dalcídio Jurandir. E assim comparar com a atual organização espacial da cidade a partir do uso das geotecnologias para espacializar, identificar, analisar e representar o espaço através de mapas temáticos gerados a partir do mapeamento geoliterário.

  10. Estudo experimental do sequenciamento das manobras da ligamentotaxia na descompressão do canal vertebral Experimental study of ligamentotaxis maneuvers sequencing in vertebral canal decompression

    Directory of Open Access Journals (Sweden)

    Ilton José Carrilho de Castro

    2008-01-01

    Full Text Available A descompressão do canal vertebral, para aliviar as estruturas nervosas, pode ser realizada por meio da ligamentotaxia. O objetivo foi analisar a influência da seqüência de realização da ligamentotaxia sobre a descompressão do canal vertebral. Foram utilizados segmentos de vértebras de suínos (Landrace. Um equipamento especialmente desenvolvido foi utilizado para produção de fratura do tipo explosão. Após a tomografia computadorizada, 10 espécimes que melhores apresentavam fraturas do tipo explosão foram fixados com fixador interno (Synthes. Foram formados dois grupos. No primeiro (n=5 foi realizada a lordose e depois a distração. Posteriormente, foram submetidos à nova compressão por meio de morsa até o retorno da fratura à posição inicial, a seguir foram novamente submetidos à distração e lordose. No segundo grupo (n=5 foi realizada a distração e depois a lordose. Após cada manobra era realizado o exame tomográfico para medir o diâmetro do canal vertebral. Os deslocamentos dos fragmentos dos corpos vertebrais fraturados foram mensurados e comparados utilizando t de Student (pVertebral canal decompression, intended to provide relief to nervous structures, may be performed by means of legamentotaxis. The objective of this study was to assess the influence of the ligamentotaxis sequence on vertebral canal decompression. Vertebral segments of Landrace swine specimens were used. A device especially developed for producing a burst-type fracture was employed. Subsequently to the computerized tomography scan, 10 specimens that best showed a burst-type fracture were fixated with internal fixator (Synthes. Two groups were formed. On the first group (n=5, lordosis followed by distraction were performed. Then, they were submitted to distraction and lordosis. On the second group (n=5, distraction was provided first, and then lordosis was performed. After each maneuver, vertebral canal was measured by tomography scan

  11. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19,2016 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  12. Magnetoacoustic Tomography with Magnetic Induction (MAT-MI) for Imaging Electrical Conductivity of Biological Tissue: A Tutorial Review

    Science.gov (United States)

    Li, Xu; Yu, Kai; He, Bin

    2016-01-01

    Magnetoacoustic tomography with magnetic induction (MAT-MI) is a noninvasive imaging method developed to map electrical conductivity of biological tissue with millimeter level spatial resolution. In MAT-MI, a time-varying magnetic stimulation is applied to induce eddy current inside the conductive tissue sample. With the existence of a static magnetic field, the Lorentz force acting on the induced eddy current drives mechanical vibrations producing detectable ultrasound signals. These ultrasound signals can then be acquired to reconstruct a map related to the sample’s electrical conductivity contrast. This work reviews fundamental ideas of MAT-MI and major techniques developed in these years. First, the physical mechanisms underlying MAT-MI imaging are described including the magnetic induction and Lorentz force induced acoustic wave propagation. Second, experimental setups and various imaging strategies for MAT-MI are reviewed and compared together with the corresponding experimental results. In addition, as a recently developed reverse mode of MAT-MI, magneto-acousto-electrical tomography with magnetic induction (MAET-MI) is briefly reviewed in terms of its theory and experimental studies. Finally, we give our opinions on existing challenges and future directions for MAT-MI research. With all the reported and future technical advancement, MAT-MI has the potential to become an important noninvasive modality for electrical conductivity imaging of biological tissue. PMID:27542088

  13. Fundamentals for routined utilization of tomography in beam diagnostic

    International Nuclear Information System (INIS)

    Reichau, Hermine

    2012-01-01

    A general and systematic approach to implement tomography for beam diagnostics has been invented and exemplarily shown for the invention of beam tomography for the Frankfurt Neutron Source. Following the diagnostic pipeline the first step was to prepare the data basis for the tomography reconstruction. For the monitoring, standard parameters have to be obtained with sufficient accuracy. In the context of this work, tomography has been kept as flexible as possible. Firstly, it will be used for the analysis of beam dynamics but also for the further development of beam tomography for routined utilization. Later on it will have to serve as a monitoring system at the end of the LEBT of FRANZ. The data preparation for tomography was demonstrated step by step. The iterated backprojection (FBP) algorithm was derived to show the basic idea of tomography which is contained in all forms of tomography algorithms. In connection with data exhibiting a high signal to noise ratio the FBP obtains the result with the highest accuracy, beyond that the accuracy can be controlled by the number of projections. The algebraic reconstruction and maximum entropy approach were outlined in a nutshell. By the introduction of the diagnostic pipeline in combination with the decision systematics the basis for a routined utilization of tomography in ion beam diagnostics have been established and exemplarily demonstrated on the introduction of beam tomography for FRANZ. A rotatable vacuum chamber has been developed to close a gap between the availability of projections to use the FBP and the small physical space on which they have to be determined. (orig.)

  14. Qualidade de vida em pacientes com endometriose: um estudo de revisão

    Directory of Open Access Journals (Sweden)

    Maria Paula Custódio Silva

    2014-09-01

    Full Text Available Objetivo: O presente estudo teve como objetivo mostrar os principais resultados dos estudos que avaliaram qualidade de vida (QV em mulheres com endometriose. Também são apresentadas estratégias para promoção da saúde, visando demonstrar as pacientes com essa condição ginecológica que é possível viver bem mesmo sendo portadora de uma doença crônica. Métodos: Para isso, foi realizada uma pesquisa bibliográfica no PubMed utilizando os descritores quality of life and endometriosis e os seguintes filtros: artigos com abstract disponível, com data de publicação dos últimos 10 anos, em humanos do sexo feminino, idioma inglês/português e cujos termos constavam no título/abstract. A busca foi realizada em dezembro de 2013, resultou em 147 artigos e de acordo com os critérios de inclusão, 12 foram selecionados para leitura. Resultados: Todos os artigos evidenciaram que as mulheres com endometriose apresentaram uma redução na QV e cinco estudos associaram nível socioeconômico, intensidade da dor e hábitos saudáveis como fatores que influenciam a QV dessa população. No entanto, nenhum dos estudos propõe as pacientes com a doença estratégias para a melhora da QV. O presente estudo mostra os benefícios da prática regular de atividade física em elevar a QV e, portanto, estimula sua realização como uma maneira de minimizar os sintomas da endometriose, em especial a dor e os sintomas psicológicos. Conclusão: Considerando que a endometriose é uma doença complexa e prevalente, o ideal seria o fornecimento de um atendimento holístico as pacientes, executado por uma equipe multidisciplinar que atuaria de modo integrado na orientação, acompanhamento e tratamento das mulheres com endometriose.

  15. Introducing passive matched field acoustic tomography

    International Nuclear Information System (INIS)

    Gasparini, O.; Camporeale, C.; Crise, A.

    1997-01-01

    In acoustic tomography sea-basin environmental parameters such as temperature profiles and current-velocities are derived, when ray propagation models are adopted, by the travel time estimates relative to the identifiable ray paths. The transmitted signals are either single frequency, or impulsive, or intermittent and deterministic. When the wavelength is comparable with the scale lengths present in the propagation scenario, Matched Field Tomography (MFT) is used, entailing the consideration of waveguide modes instead of rays. A new concept in tomography is introduced in the paper, that employs passively the noise emitted by ships of opportunity (cargoes, ferries) as source signals. The passive technique is acoustic-pollution-free, and if a basin is selected in which a regular ship traffic occurs data can be received on a regular schedule, with no transmission cost. A novel array pre-processor for passive tomography is introduced, such that the signal structure at the pre-processor output in nearly the same as that obtainable in the case of single-frequency source signals

  16. Application of process tomography in gas-solid fluidised beds in different scales and structures

    Science.gov (United States)

    Wang, H. G.; Che, H. Q.; Ye, J. M.; Tu, Q. Y.; Wu, Z. P.; Yang, W. Q.; Ocone, R.

    2018-04-01

    Gas-solid fluidised beds are commonly used in particle-related processes, e.g. for coal combustion and gasification in the power industry, and the coating and granulation process in the pharmaceutical industry. Because the operation efficiency depends on the gas-solid flow characteristics, it is necessary to investigate the flow behaviour. This paper is about the application of process tomography, including electrical capacitance tomography (ECT) and microwave tomography (MWT), in multi-scale gas-solid fluidisation processes in the pharmaceutical and power industries. This is the first time that both ECT and MWT have been applied for this purpose in multi-scale and complex structure. To evaluate the sensor design and image reconstruction and to investigate the effects of sensor structure and dimension on the image quality, a normalised sensitivity coefficient is introduced. In the meantime, computational fluid dynamic (CFD) analysis based on a computational particle fluid dynamic (CPFD) model and a two-phase fluid model (TFM) is used. Part of the CPFD-TFM simulation results are compared and validated by experimental results from ECT and/or MWT. By both simulation and experiment, the complex flow hydrodynamic behaviour in different scales is analysed. Time-series capacitance data are analysed both in time and frequency domains to reveal the flow characteristics.

  17. One step geometrical calibration method for optical coherence tomography

    International Nuclear Information System (INIS)

    Díaz, Jesús Díaz; Ortmaier, Tobias; Stritzel, Jenny; Rahlves, Maik; Reithmeier, Eduard; Roth, Bernhard; Majdani, Omid

    2016-01-01

    We present a novel one-step calibration methodology for geometrical distortion correction for optical coherence tomography (OCT). A calibration standard especially designed for OCT is introduced, which consists of an array of inverse pyramidal structures. The use of multiple landmarks situated on four different height levels on the pyramids allow performing a 3D geometrical calibration. The calibration procedure itself is based on a parametric model of the OCT beam propagation. It is validated by experimental results and enables the reduction of systematic errors by more than one order of magnitude. In future, our results can improve OCT image reconstruction and interpretation for medical applications such as real time monitoring of surgery. (paper)

  18. Precision measurements of linear scattering density using muon tomography

    Science.gov (United States)

    Åström, E.; Bonomi, G.; Calliari, I.; Calvini, P.; Checchia, P.; Donzella, A.; Faraci, E.; Forsberg, F.; Gonella, F.; Hu, X.; Klinger, J.; Sundqvist Ökvist, L.; Pagano, D.; Rigoni, A.; Ramous, E.; Urbani, M.; Vanini, S.; Zenoni, A.; Zumerle, G.

    2016-07-01

    We demonstrate that muon tomography can be used to precisely measure the properties of various materials. The materials which have been considered have been extracted from an experimental blast furnace, including carbon (coke) and iron oxides, for which measurements of the linear scattering density relative to the mass density have been performed with an absolute precision of 10%. We report the procedures that are used in order to obtain such precision, and a discussion is presented to address the expected performance of the technique when applied to heavier materials. The results we obtain do not depend on the specific type of material considered and therefore they can be extended to any application.

  19. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  20. Three dimensional (3D) microstructure-based finite element modeling of Al-SiC nanolaminates using focused ion beam (FIB) tomography

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, Carl R. [Materials Science and Engineering, Arizona State University, Tempe, AZ 85287-6106 (United States); Molina-Aladareguia, Jon [IMDEA Materials Institute, c/Eric Kandel 2, Getafe, Madrid 28906 (Spain); Chawla, Nikhilesh, E-mail: nchawla@asu.edu [Materials Science and Engineering, Arizona State University, Tempe, AZ 85287-6106 (United States)

    2016-10-15

    Al-SiC nanolaminate composites show promise as high performance coating materials due to their combination of strength and toughness. Although a significant amount of modeling effort has been focused on materials with an idealized flat nanostructure, experimentally these materials exhibit complex undulating layer geometries. This work utilizes FIB tomography to characterize this nanostructure in 3D and finite element modeling to determine the effect that this complex structure has on the mechanical behavior of these materials. A sufficiently large volume was characterized such that a 1 × 2 μm micropillar could be generated from the dataset and compared directly to experimental results. The mechanical response from this nanostructure was then compared to pillar models using simplified structures with perfectly flat layers, layers with sinusoidal waviness, and layers with arc segment waviness. The arc segment based layer geometry showed the best agreement with the experimentally determined structure, indicating it would be the most appropriate geometry for future modeling efforts. - Highlights: •FIB tomography was used to determine the structure of an Al-SiC nanolaminate in 3D. •FEM was used to compare the deformation of the nanostructure to experimental results. •Idealized structures from literature were compared to the FIB determined structure. •Arc segment based structures approximated the FIB determined structure most closely.

  1. Sensing across large-scale cognitive radio networks: Data processing, algorithms, and testbed for wireless tomography and moving target tracking

    Science.gov (United States)

    Bonior, Jason David

    As the use of wireless devices has become more widespread so has the potential for utilizing wireless networks for remote sensing applications. Regular wireless communication devices are not typically designed for remote sensing. Remote sensing techniques must be carefully tailored to the capabilities of these networks before they can be applied. Experimental verification of these techniques and algorithms requires robust yet flexible testbeds. In this dissertation, two experimental testbeds for the advancement of research into sensing across large-scale cognitive radio networks are presented. System architectures, implementations, capabilities, experimental verification, and performance are discussed. One testbed is designed for the collection of scattering data to be used in RF and wireless tomography research. This system is used to collect full complex scattering data using a vector network analyzer (VNA) and amplitude-only data using non-synchronous software-defined radios (SDRs). Collected data is used to experimentally validate a technique for phase reconstruction using semidefinite relaxation and demonstrate the feasibility of wireless tomography. The second testbed is a SDR network for the collection of experimental data. The development of tools for network maintenance and data collection is presented and discussed. A novel recursive weighted centroid algorithm for device-free target localization using the variance of received signal strength for wireless links is proposed. The signal variance resulting from a moving target is modeled as having contours related to Cassini ovals. This model is used to formulate recursive weights which reduce the influence of wireless links that are farther from the target location estimate. The algorithm and its implementation on this testbed are presented and experimental results discussed.

  2. Derivation of site-specific relationships between hydraulic parameters and p-wave velocities based on hydraulic and seismic tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brauchler, R.; Doetsch, J.; Dietrich, P.; Sauter, M.

    2012-01-10

    In this study, hydraulic and seismic tomographic measurements were used to derive a site-specific relationship between the geophysical parameter p-wave velocity and the hydraulic parameters, diffusivity and specific storage. Our field study includes diffusivity tomograms derived from hydraulic travel time tomography, specific storage tomograms, derived from hydraulic attenuation tomography, and p-wave velocity tomograms, derived from seismic tomography. The tomographic inversion was performed in all three cases with the SIRT (Simultaneous Iterative Reconstruction Technique) algorithm, using a ray tracing technique with curved trajectories. The experimental set-up was designed such that the p-wave velocity tomogram overlaps the hydraulic tomograms by half. The experiments were performed at a wellcharacterized sand and gravel aquifer, located in the Leine River valley near Göttingen, Germany. Access to the shallow subsurface was provided by direct-push technology. The high spatial resolution of hydraulic and seismic tomography was exploited to derive representative site-specific relationships between the hydraulic and geophysical parameters, based on the area where geophysical and hydraulic tests were performed. The transformation of the p-wave velocities into hydraulic properties was undertaken using a k-means cluster analysis. Results demonstrate that the combination of hydraulic and geophysical tomographic data is a promising approach to improve hydrogeophysical site characterization.

  3. Evaluation of brain scintigraphy and computerized tomography

    International Nuclear Information System (INIS)

    Cavailloles, F.; Dairou, R.; Desbleds, M.T.; Benoit, C.; Larmande, P.; Bok, B.; Alperovitch, A.

    1983-01-01

    In order to assess the clinical usefulness of brain computerized tomography and radionuclide scan, a prospective study was performed on a series of 554 patients. The detection rate was assessed as well as the identification rate of lesions. In addition, the usefulness of both tests was appreciated subjectively by two neurologists reviewing the patients' files. Both give reasonably similar results: computerized tomography is superior to radionuclide scan in the diagnosis of tumors and intracerebral hematomas, the radionuclide scan being slightly superior in the diagnosis of purely ischemic CVA and subdural hematomas. The superiority which was subjectively conceded to computerized tomography was greater than that objectively demonstrated. However, clinical usefulness of computerized tomography was judged important in only 50% of the cases. Moreover, to request both computerized tomography and radionuclide scan appeared as having no interest in 83% of the cases. In that series, the diagnostic hypotheses were in agreement with the final diagnosis in 88% of the cases. Bias encountered in this type of studies are discussed [fr

  4. Study for a novel tomography technique using an imaging plate

    CERN Document Server

    Kobayashi, H; Matsubayashi, M

    1999-01-01

    A sinogram is directly recorded onto an imaging plate for neutron tomography, which has excellent capability to detect neutrons. A sinogram-recording-system and outline of the data processing are explained briefly. A tomogram of a test object is reconstructed and shown as the preliminary result. The linearity of CT values was experimentally confirmed up to 1.6 cm sup - sup 1 of effective total macroscopic cross section, but about 10% lower CT value was observed at 2.7 cm sup - sup 1. The linearity limitation and statistical character of CT values are discussed with regard to the dynamic range of the system as well as the effect of background components.

  5. Tendências dos estudos com idosos mais velhos na comunidade: uma revisão sistemática (internacional

    Directory of Open Access Journals (Sweden)

    Idiane Rosset

    2011-03-01

    Full Text Available O estudo objetivou identificar e analisar as tendências e tipos de estudos, publicados no país e no exterior, envolvendo idosos >80 anos residentes na comunidade. Realizou-se uma revisão sistemática da literatura nacional nas bases de dados LILACS e SciELO e internacional nas bases PUBMED e EMBASE, nas duas últimas décadas. Selecionaram-se 162 referências internacionais e 12 nacionais. Predominou a área das ciências biológicas, tanto no nível nacional (50% quanto internacional (74,1%. Todos os trabalhos nacionais foram observacionais, sendo 91,7% de estudos transversais. Dentre os internacionais, 93,3% foram observacionais. Destes, 48,1% de estudos transversais e 37,6% de estudos de corte. Os Estados Unidos foram responsáveis por 41,4% do total de publicações internacionais. O Brasil e a China foram os únicos países em desenvolvimento a apresentar produções internacionais. Apesar do significativo aumento no número de produções científicas internacionais a partir de 2005, o mesmo ainda não foi constatado em nível nacional.

  6. Computerized tomography in myotonic dystrophy

    International Nuclear Information System (INIS)

    Gellerich, I.; Mueller, D.; Koch, R.D.

    1986-01-01

    Besides clinical symptoms, progress and electromyography computerized tomography improves the diagnostics of myotonic dystrophy. Even small changes in muscular structure are detectable and especially the musculus soleus exhibits early and pronounced alterations. By means of density distribution pattern an improved characterization of the disease is possible. Additional information is obtained by cerebral computerized tomography. Atrophy of brain tissue is to be expected in all patients with myotonic dystrophy. (author)

  7. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Kretschmann, H.J.; Weinrich, W.

    1985-01-01

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  8. Polycapillary based μXRF station for 3D colour tomography

    Science.gov (United States)

    Hampai, D.; Cherepennikov, Yu. M.; Liedl, A.; Cappuccio, G.; Capitolo, E.; Iannarelli, M.; Azzutti, C.; Gladkikh, Yu. P.; Marcelli, A.; Dabagov, S. B.

    2018-04-01

    The "Rainbow X-Ray" (RXR) experimental station at XLab Frascati of the Frascati's National Laboratories (LNF) INFN is a dedicated station for X-ray fluorescence studies based on the use of polycapillary lenses in a confocal geometry. The flexible RXR layout allows investigating specimens of the dimensions ranging from several millimeters up to half meter and weighting up to several tens of kilograms. Compared to similar existing XRF stations, apart of the possibility for investigating large samples, the main advantage of this equipment is the detection system with two spectrometers optimized to work separately at high and at low X-ray energies. The confocal geometry combined with a 3-axes fine motion system makes possible 3D μXRF elemental tomographic acquisitions (colour tomography). At present this station in operation at high XRF energies is used for cultural heritage and geological applications. We present and discuss here the analytical performances of this experimental station pointing out the advantages in different application areas.

  9. APRENDIZAGEM INDIVIDUAL, SUPORTE ORGANIZACIONAL E DESEMPENHO PERCEBIDO: UM ESTUDO COM DOCENTES UNIVERSITÁRIOS

    Directory of Open Access Journals (Sweden)

    Pérola Cavalcante Dourado

    2018-03-01

    Full Text Available Resumo: O estudo analisou as relações entre a percepção de aprendizagem de competências e de desempenho de docentes de nível superior. Além disso, testou o papel moderador do suporte organizacional na relação entre a aprendizagem individual e desempenho docente. Participaram do estudo 275 docentes de uma universidade pública federal, que responderam ao inventário de percepção de aprendizagem de competências, suporte à transferência e desempenho docente (ASOD. Foram realizadas análises confirmatórias e testados os modelos de predição e moderação. Uma das conclusões do estudo foi que a aprendizagem docente nas atividades de ensino, pesquisa, extensão e gestão predizem a percepção de desempenho em cada uma das atividades respectivamente. Não foram encontradas evidências de que o suporte modera as relações entre as aprendizagens e a percepção de desempenho docente.

  10. Tumour screening by means of tomography methods

    International Nuclear Information System (INIS)

    Diederich, S.

    2005-01-01

    Tomography methods such as computer tomography (CT), magnetic resonance tomography (MRT), and sonography/ultrasound examinations make it possible to detect small asymptomatic tumours, thus potentially preventing their manifestation at an advanced stage and improving survival prospects for the patients concerned. There are data available on various common tumours which show that modern tomography methods are capable of detecting not only small asymptomatic tumours but also their benign precursors (e.g. polyps of the large intestine). This has been demonstrated for lung cancer, colon cancer and breast cancer. However, it has not been possible to date to show for any tomography method or any type of tumour that the systematic use of such diagnostic procedures does anything to lower the mortality rate for that tumour. For other types of tumour (pancreatic cancer, kidney cancer, ovary cancer) the above named methods are either not sufficiently sensitive or the body of data that has accumulated on their respective use is too small to judge the benefit of tomography screenings. Current technical developments make it appear probable that for many types of cancer the reliability with which small tumours can be detected will improve in future. Studies aimed at clarifying the potential of screenings for reducing mortality rates are already underway for lung cancer and would be worthwhile performing for other tumour types

  11. Gestão em Alimentos e Bebidas: Indicadores para um Novo Campo de Estudos no Brasil

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo de Mattos

    2016-10-01

    Full Text Available A partir de dezembro de 2015 a CAPES reconheceu formalmente a proposta de abertura de um novo curso em Mestrado Profissional em Administração com foco na Gestão em Alimentos e Bebidas. Ainda que no exterior este campo de pesquisa (Food and Beverage Management já esteja consolidado, no Brasil ele é formalmente inédito. Este estudo tem o propósito de identificar, por meio de pesquisa bibliográfica nas bases de dados EBSCO e Food and Beverage Management Commons, as áreas de estudo de alimentos e bebidas no campo da administração de empresas. A pesquisa também possui o objetivo de quantificar, de forma longitudinal, o número de estudos por área. Os resultados identificaram 18 áreas da administração de empresas em que existem pesquisas sobre alimentos e bebidas. Os resultados, também, quantificaram o número de publicações e demonstraram, ao longo do tempo, a partir da década de 1960, o progresso e os turns (períodos de grandes evoluções na produção dos estudos em alimentos e bebidas em cada década. Este artigo contribuiu, de forma seminal, para mapear a área e fornecer indicadores de sua produção científica. O estudo contribuiu, também, para direcionar investigações futuras.

  12. Statistical reconstruction for cosmic ray muon tomography.

    Science.gov (United States)

    Schultz, Larry J; Blanpied, Gary S; Borozdin, Konstantin N; Fraser, Andrew M; Hengartner, Nicolas W; Klimenko, Alexei V; Morris, Christopher L; Orum, Chris; Sossong, Michael J

    2007-08-01

    Highly penetrating cosmic ray muons constantly shower the earth at a rate of about 1 muon per cm2 per minute. We have developed a technique which exploits the multiple Coulomb scattering of these particles to perform nondestructive inspection without the use of artificial radiation. In prior work [1]-[3], we have described heuristic methods for processing muon data to create reconstructed images. In this paper, we present a maximum likelihood/expectation maximization tomographic reconstruction algorithm designed for the technique. This algorithm borrows much from techniques used in medical imaging, particularly emission tomography, but the statistics of muon scattering dictates differences. We describe the statistical model for multiple scattering, derive the reconstruction algorithm, and present simulated examples. We also propose methods to improve the robustness of the algorithm to experimental errors and events departing from the statistical model.

  13. Computed tomography of the facial canal

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    The radiological details of the facial canal was investigated by computed tomography. In the first part of this study, dry skulls were used to delineate the full course of the facial canal by computed tomography. In the second part of this study, the patients with chronic otitis media and secondary cholesteatoma were evaluated. The labyrinthine and tympanic parts of the canal were well demonstrated with the axial scanning, and the mastoid part with the coronal scanning. Moreover, computed tomography showed excellent delineation of the middle ear contents. In patients with secondary cholesteatoma, the destructions of the intratympanic course of the bony facial canal were also assessed preoperatively. (author)

  14. Computed tomography of post-traumatic orbito-palpebral emphysema

    International Nuclear Information System (INIS)

    Nose, Harumi; Kohno, Keiko

    1981-01-01

    Two cases of orbito-palpebral emphysema are described. Both having a history of recent facial trauma, emphysema occurred after blowing the nose. They were studied by computed tomography and plain x-ray film, including tomograms of the orbit. The emphysema was revealed by computed tomography and x-ray film, but more clearly by the former technique. The fracture lines of the orbit were revealed in only one case by x-ray film, but in both cases by computed tomography. The authors stress that computed tomography is the best technique for the study of orbital emphysema. (author)

  15. Novas Modulações do Controle Organizacional: um Estudo de Caso

    Directory of Open Access Journals (Sweden)

    Cláudia Maria Perrone

    Full Text Available Resumo O poder nas organizações não se manifesta apenas por vias coercitivas na atualidade. Ele atua por meio de dispositivos de poder, nos quais são incluídos os métodos disciplinares, que operam diretamente na subjetividade do sujeito. Esses mecanismos tornam os trabalhadores reconhecíveis, identificáveis e comparáveis entre si. Este estudo objetivou explicitar parte dos resultados de uma pesquisa sobre controle organizacional e subjetividade no contemporâneo. A pesquisa referida investigou a lógica pós-disciplinar presente nos mecanismos de controle organizacional por meio da problematização do nexo entre tecnologia e subjetivação. Os resultados apresentados neste trabalho são relativos a uma parte da amostra total, composta de trinta sujeitos. Foi escolhido o caso de uma mulher, funcionária de uma instituição financeira transnacional, configurando este artigo como um estudo de caso. Os resultados do estudo de caso apontaram que a lógica vigente da organização do trabalho obriga que o trabalhador assuma para si as flutuações da demanda, bem como a responsabilidade dos resultados. Dessa forma, há indicativos que as novas formas de organização do trabalho possibilitam a autorresponsabilização do sujeito.

  16. F-18-fluorodeoxyglucose-positron emission tomography in colorectal cancer

    International Nuclear Information System (INIS)

    Joerg, L.; Langsteger, W.

    2002-01-01

    Whole-body positron emission tomography (PET) with the radiolabeled glucose analog F-18-fluorodeoxyglucose (F-18-FDG) is a sensitive diagnostic tool that images tumors based on increased uptake of glucose. Several recent publications have shown that F-18-fluorodeoxyglucose-positron emission tomography is more sensitive than computed-tomography (CT) in detecting colorectal cancer. In patients with increasing CEA (carcinoembryonic antigen) and no evidence of recurrent disease on CT F-18-fluorodeoxyglucose-positron emission tomography often detects recurrent cancer. In all, patient management seems to be changed in about 25 % of patients who undergo F-18-fluorodeoxyglucose-positron emission tomography in addition to standard staging procedure. Limited reports to date on both chemotherapy and radiotherapy support the role of F-18-fluorodeoxyglucose-positron emission tomography in assessing treatment response. Also regarding preoperative staging of primary colorectal cancer the literature is very limited. (author)

  17. Experimental stations at I13 beamline at Diamond Light Source

    Science.gov (United States)

    Pešić, Z. D.; De Fanis, A.; Wagner, U.; Rau, C.

    2013-03-01

    The I13 beamline of Diamond Light Source has been operational since December 2011. The beamline encompass two fully independent branches devoted to coherent imaging experiments (coherent x-ray diffraction, coherent diffraction imaging and ptychography) and x-ray imaging (in-line phase contrast imaging, tomography and full-field microscopy). This paper gives an overview of the current status of experimental stations on both branches and outlines planned developments.

  18. Experimental stations at I13 beamline at Diamond Light Source

    International Nuclear Information System (INIS)

    Pešić, Z D; Fanis, A De; Wagner, U; Rau, C

    2013-01-01

    The I13 beamline of Diamond Light Source has been operational since December 2011. The beamline encompass two fully independent branches devoted to coherent imaging experiments (coherent x-ray diffraction, coherent diffraction imaging and ptychography) and x-ray imaging (in-line phase contrast imaging, tomography and full-field microscopy). This paper gives an overview of the current status of experimental stations on both branches and outlines planned developments.

  19. Ceramic and polymeric dental onlays evaluated by photo-elasticity, optical coherence tomography, and micro-computed tomography

    Science.gov (United States)

    Sinescu, Cosmin; Negrutiu, Meda; Topala, Florin; Ionita, Ciprian; Negru, Radu; Fabriky, Mihai; Marcauteanu, Corina; Bradu, Adrian; Dobre, George; Marsavina, Liviu; Rominu, Mihai; Podoleanu, Adrian

    2011-10-01

    Dental onlays are restorations used to repair rear teeth that have a mild to moderate amount of decay. They can also be used to restore teeth that are cracked or fractured if the damage is not severe enough to require a dental crown. The use of onlays requires less tooth reduction than does the use of metal fillings. This allows dentists to conserve more of a patient's natural tooth structure in the treatment process. The aims of this study are to evaluate the biomechanical comportment of the dental onlays, by using the 3D photo elasticity method and to investigate the integrity of the structures and their fitting to the dental support. For this optical coherence tomography and micro-computed tomography were employed. Both methods were used to investigate 37 dental onlays, 17 integral polymeric and 20 integral ceramic. The results permit to observe materials defects inside the ceramic or polymeric onlays situate in the biomechanically tensioned areas that could lead to fracture of the prosthetic structure. Marginal fitting problems of the onlays related to the teeth preparations were presented in order to observe the possibility of secondary cavities. The resulted images from the optical coherence tomography were verified by the micro-computed tomography. In conclusion, the optical coherence tomography can be used as a clinical method in order to evaluate the integrity of the dental ceramic and polymeric onlays and to investigate the quality of the marginal fitting to the teeth preparations.

  20. Measurements of dose distribution in thyroids, gonads, crystalline and other organs, for radio-diagnostics with computorized tomography

    International Nuclear Information System (INIS)

    Coelho, M.J.

    1983-01-01

    An evaluation of radiation doses in organs, from radiologic examinations by computorized tomography was done, comparing with theoretic data obtained by Monte Carlo method. The measurements were done with help of a 'Rando Alderson Phantom' exposed to irradiation coming from a 0450 AS and E Pfizer Tomographic. The cases under study were the head and abdomen examinations. The dose assessment was done by using mini TLD's of LiF. The calculated dose equivalents were obtained by using the Monte Carlo method applied to a mathematical antropomorphic phantom, simulating the same experimental arrangements. The results were compared with the experimental one. (E.G.) [pt

  1. The Comparison of Computed Tomography Perfusion, Contrast-Enhanced Computed Tomography and Positron-Emission Tomography/Computed Tomography for the Detection of Primary Esophageal Carcinoma.

    Science.gov (United States)

    Genc, Berhan; Kantarci, Mecit; Sade, Recep; Orsal, Ebru; Ogul, Hayri; Okur, Aylin; Aydin, Yener; Karaca, Leyla; Eroğlu, Atilla

    2016-01-01

    The purpose of this study was to investigate the efficiency of computed tomography perfusion (CTP), contrast-enhanced computed tomography (CECT) and 18F-fluoro-2-deoxy-D-glucose (18F-FDG) positron-emission tomography (PET/CT) in the diagnosis of esophageal cancer. This prospective study consisted of 33 patients with pathologically confirmed esophageal cancer, 2 of whom had an esophageal abscess. All the patients underwent CTP, CECT and PET/CT imaging and the imaging findings were evaluated. Sensitivity, specificity and positive and negative predictive values were calculated for each of the 3 imaging modalities relative to the histological diagnosis. Thirty-three tumors were visualized on CTP, 29 on CECT and 27 on PET/CT. Six tumors were stage 1, and 2 and 4 of these tumors were missed on CECT and PET/CT, respectively. Significant differences between CTP and CECT (p = 0.02), and between CTP and PET/CT (p = 0.04) were found for stage 1 tumors. Values for the sensitivity, specificity and positive and negative predictive values on CTP were 100, 100, 100 and 100%, respectively. Corresponding values on CECT were 93.94, 0, 93.94 and 0%, respectively, and those on PET/CT were 87.88, 0, 93.55 and 0%, respectively. Hence, the sensitivity, specificity and positive and negative predictive values of CTP were better than those of CECT and PET/CT. CTP had an advantage over CECT and PET/CT in detecting small lesions. CTP was valuable, especially in detecting stage 1 tumors. © 2016 S. Karger AG, Basel.

  2. Theoretical and Experimental Study of Optical Coherence Tomography (OCT) Signals Using an Analytical Transport Model

    International Nuclear Information System (INIS)

    Vazquez Villa, A.; Delgado Atencio, J. A.; Vazquez y Montiel, S.; Cunill Rodriguez, M.; Martinez Rodriguez, A. E.; Ramos, J. Castro; Villanueva, A.

    2010-01-01

    Optical coherence tomography (OCT) is a non-invasive low coherent interferometric technique that provides cross-sectional images of turbid media. OCT is based on the classical Michelson interferometer where the mirror of the reference arm is oscillating and the signal arm contains a biological sample. In this work, we analyzed theoretically the heterodyne optical signal adopting the so called extended Huygens-Fresnel principle (EHFP). We use simulated OCT images with known optical properties to test an algorithm developed by ourselves to recover the scattering coefficient and we recovered the scattering coefficient with a relative error less than 5% for noisy signals. In addition, we applied this algorithm to OCT images from phantoms of known optical properties; in this case curves were indistinguishable. A revision of the validity of the analytical model applied to our system should be done.

  3. Positron emission tomography

    International Nuclear Information System (INIS)

    Yamamoto, Y.L.; Thompson, C.J.; Diksic, M.; Meyer, E.; Feindel, W.H.

    1984-01-01

    One of the most exciting new technologies introduced in the last 10 yr is positron emission tomography (PET). PET provides quantitative, three-dimensional images for the study of specific biochemical and physiological processes in the human body. This approach is analogous to quantitative in-vivo autoradiography but has the added advantage of permitting non-invasive in vivo studies. PET scanning requires a small cyclotron to produce short-lived positron emitting isotopes such as oxygen-15, carbon-11, nitrogen-13 and fluorine-18. Proper radiochemical facilities and advanced computer equipment are also needed. Most important, PET requires a multidisciplinary scientific team of physicists, radiochemists, mathematicians, biochemists and physicians. The most recent trends are reviewed in the imaging technology, radiochemistry, methodology and clinical applications of positron emission tomography. (author)

  4. Avaliação do efeito do Risedronato Sódico na consolidação de fraturas: estudo experimental em ratos The evaluation of the Sodic Risedronate effect in the fractures consolidation: experimental study with rats

    Directory of Open Access Journals (Sweden)

    Luiz Antonio Alcântara de Oliveira

    2004-06-01

    Full Text Available Realizou-se um estudo experimental com 40 ratos da raça Lewis visando-se avaliar a influência do risedronato sódico na consolidação de fraturas em animais submetidos à dieta aprotéica e dieta protéica, divididos aleatoriamente em quatro grupos, com 10 animais em cada grupo, assim constituídos: grupo I, com dieta protéica, sem risedronato (grupo controle; grupo II, dieta protéica, com risedronato; grupo III, dieta aprotéica, sem risedrionato; grupo IV, dieta aprotéica, com risedronato. Os ratos foram submetidos a fraturas semelhantes, no 15º dia e à eutanásia no 43º dia do experimento. As variáveis analisadas incluíram a evolução ponderal, avaliação radiográfica, densitometria óssea, avaliação histomorfométrica do calo ósseo, dosagens sanguíneas de cálcio, fósforo, fosfatase alcalina, proteínas totais, albumina e osteocalcina. Concluiu-se que o risedronato exerceu influência positiva no processo de consolidação de fraturas em ratos nutridos e desnutridos, e aumentou a densidade mineral óssea. O risedronato ocasionou a formação de tecido ósseo maduro de melhor qualidade e morfologia.A experimental study with 40 rats of the Lewis type was done focusing the influence of sodic risedronate on fractures consolidation in the animals. They were submitted to a protein nutrition diet to a non-protein one, divided randomly in four groups, having 10 animals in each group. Like this: group 1, with a protein nutrition diet, without risedronate (control group; group II, protein nutrition diet t with risedronate , group III, non-protein diet, without risedronate; group IV, non-protein diet with risedronate. The rats were submitted to similar fractures, on the 15º day and to the euthanasia on the 43º of the experiment. The variability analyzed included the ponderous evaluation, radiographic evaluation, the bone densitometry, histomorphometric bone callus evaluation, blood dosage of calcium, phosphorus, alkaline

  5. Myocardial blood flow quantification for evaluation of coronary artery disease by positron emission tomography, cardiac magnetic resonance imaging, and computed tomography.

    Science.gov (United States)

    Waller, Alfonso H; Blankstein, Ron; Kwong, Raymond Y; Di Carli, Marcelo F

    2014-05-01

    The noninvasive detection of the presence and functional significance of coronary artery stenosis is important in the diagnosis, risk assessment, and management of patients with known or suspected coronary artery disease. Quantitative assessment of myocardial perfusion can provide an objective and reproducible estimate of myocardial ischemia and risk prediction. Positron emission tomography, cardiac magnetic resonance, and cardiac computed tomography perfusion are modalities capable of measuring myocardial blood flow and coronary flow reserve. In this review, we will discuss the technical aspects of quantitative myocardial perfusion imaging with positron emission tomography, cardiac magnetic resonance imaging, and computed tomography, and its emerging clinical applications.

  6. Estudo de filmes de Langmuir e Langmuir-Blodgett de aminas anfifílicas utilizando a espectroscopia SFG

    OpenAIRE

    Thiers Massami Uehara

    2010-01-01

    O estudo da interação de moléculas orgânicas com a água é de grande importância para diversas áreas das ciências, como por exemplo, na compreensão de sistemas biológicos. Uma elevada diversidade de estudos nesta área já foram realizados, no entanto, alguns aspectos do estudo de filmes finos de aminas anfifílicas não foram satisfatoriamente esclarecidos. Este trabalho aborda filmes de Langmuir de octadecilamina em função do pH e da força iônica de subfases aquosas, investigando a estrutura d...

  7. GESTÃO DO VOLUNTARIADO: Um Panorama dos Estudos Realizados no Brasil.

    Directory of Open Access Journals (Sweden)

    Sheila Patrícia Ramos

    2016-08-01

    Full Text Available Um novo padrão de voluntariado iniciou a partir de 1990 no Brasil, foram criados centros de referência que tinham por objetivo organizar, capacitar e direcionar o trabalho voluntário. A presente pesquisa tem como objetivo analisar os estudos publicados no Brasil sobre o tema gestão do voluntariado e com isso pretende-se mapear estudos teóricos e empíricos nacionais. Para tanto, foi realizada uma pesquisa bibliométrica, de caráter exploratório-descritiva, em dados secundários. Os resultados foram dispostos em forma de tabela. A amostra foi composta por quinze estudos, sendo artigos científicos publicados em revistas e eventos. A média de autores identificados nos artigos foram de 2,4. Predominam as pesquisas práticas e qualitativas com uso da técnica de entrevista apoiado pelo uso de documentos e/ou observação.  80% das pesquisas são qualitativas e 20% de natureza quali/quanti. 80% dos estudos identificados são práticos, 60% foram publicados em fontes classificadas pela CAPES como “B” e 40% “A”.    A new voluntary standard started from 1990 in Brazil, the reference centers have been created that aimed to organize, train and direct volunteer work. This research aims to analyze the studies published in Brazil the problem of volunteer management and aims to map theoretical and empirical national. For this, a bibliometric, descriptive and exploratory research was conducted on secondary data. The results were arranged in a table. The sample consisted of fifteen scientific studies and articles published in magazines and events. The average number of authors identified in Articles 2.4. Predominance of practice and qualitative research using the interview technique with the support of the use of documents and / or observation. 80% of research is qualitative and 20% qualitative / quantitative nature. 80% of the identified studies are practical, 60% were published in classified by CAPES as "B" and 40% "A" sources.

  8. Computed Tomography Technology: Development and Applications for Defence

    International Nuclear Information System (INIS)

    Baheti, G. L.; Saxena, Nisheet; Tripathi, D. K.; Songara, K. C.; Meghwal, L. R.; Meena, V. L.

    2008-01-01

    Computed Tomography(CT) has revolutionized the field of Non-Destructive Testing and Evaluation (NDT and E). Tomography for industrial applications warrants design and development of customized solutions catering to specific visualization requirements. Present paper highlights Tomography Technology Solutions implemented at Defence Laboratory, Jodhpur (DLJ). Details on the technological developments carried out and their utilization for various Defence applications has been covered.

  9. Os sistemas agroflorestais como alternativa econômica em pequenas propriedades rurais: estudo de caso.

    Directory of Open Access Journals (Sweden)

    Mário Jorge Campos dos Santos

    2010-08-01

    Full Text Available Os Sistemas Agroflorestais (SAFs constituem-se em uma alternativa de uso da terra para aliar a estabilidade do ecossistema visando à eficiência e otimização de recursos naturais na produção de forma integrada e sustentada. O objetivo deste estudo de caso foi avaliar a viabilidade econômica de um sistema agroflorestal localizado na região do Pontal do Paranapanema. O SAF em estudo é formada por espécies agrícolas: milho (Zea maiz, feijão guandu (Cajanus cajan, carioquinha, (Vigna unguiculata, preto (Phaseolus vulgaris e mandioca (Manihot esculenta com espécies florestais: Eucalyptus citriodora e Eucalyptus camaldulensis. A rentabilidade econômica do sistema foi mensurada, utilizando Valor Presente Líquido (VPL, Razão Benefício/Custo (RB/C para as culturas agrícolas anuais e Valor Esperado da terra (VET para os componentes madeireiros. Para tais cálculos foi escolhida uma taxa de desconto de 6%. O estudo demonstrou que o sistema agroflorestal apresentou rentabilidade econômica positiva, e que podem ser adotados por pequenos produtores. Assim, pode-se concluir que os sistemas agroflorestais são economicamente viáveis para pequenos produtores rurais trabalhando nas mesmas condições apresentadas neste estudo.

  10. Multi-Mounted X-Ray Computed Tomography.

    Science.gov (United States)

    Fu, Jian; Liu, Zhenzhong; Wang, Jingzheng

    2016-01-01

    Most existing X-ray computed tomography (CT) techniques work in single-mounted mode and need to scan the inspected objects one by one. It is time-consuming and not acceptable for the inspection in a large scale. In this paper, we report a multi-mounted CT method and its first engineering implementation. It consists of a multi-mounted scanning geometry and the corresponding algebraic iterative reconstruction algorithm. This approach permits the CT rotation scanning of multiple objects simultaneously without the increase of penetration thickness and the signal crosstalk. Compared with the conventional single-mounted methods, it has the potential to improve the imaging efficiency and suppress the artifacts from the beam hardening and the scatter. This work comprises a numerical study of the method and its experimental verification using a dataset measured with a developed multi-mounted X-ray CT prototype system. We believe that this technique is of particular interest for pushing the engineering applications of X-ray CT.

  11. EOL3 M0 X-ray Tomography Test Results

    CERN Document Server

    Avramidou, R; Bozhko, N; Borisov, A; Goriatchev, V; Goriatchev, S; Gushin, V; Fakhroutdinov, R; Kojine, A; Kononov, A; Larionov, A; Salomatin, Yu I; Schuh, S; Sedykh, Yu; Tchougouev, A

    2001-01-01

    Results of X-ray tomography test of EOL3 module 0 chamber is presented in the note. Peculiarities of the X-ray tomography of the chamber are discussed. Comparison of the tomography results with predictions of the production site measurements is made.

  12. A educação matemática e os estudos históricos comparativos A educação matemática e os estudos históricos comparativos Mathematics education and comparative historical studies

    Directory of Open Access Journals (Sweden)

    Wagner RODRIGUES VALENTE

    2013-07-01

    Full Text Available Este texto tem por objetivos: caracterizar a área de pesquisa denominada «história da educação matemática» e defender a idéia de que a educação matemática constitui tema privilegiado de pesquisa no âmbito dos estudos históricos comparativos. Utiliza-se para isso uma revisão da literatura sobre estudos comparativos, a análise de dois momentos fundamentais ocorridos no século XX onde intenta-se internacionalizar um currículo de matemática para as escolas de diferentes países e um estudo de caso trazido por projeto de cooperação internacional entre Brasil e Portugal.Este texto tem por objetivos: caracterizar a área de pesquisa denominada «história da educação matemática» e defender a idéia de que a educação matemática constitui tema privilegiado de pesquisa no âmbito dos estudos históricos comparativos. Utiliza-se para isso uma revisão da literatura sobre estudos comparativos, a análise de dois momentos fundamentais ocorridos no século XX onde intenta-se internacionalizar um currículo de matemática para as escolas de diferentes países e um estudo de caso trazido por projeto de cooperação internacional entre Brasil e Portugal.This paper has as its aims: to characterize the area of research «history of mathematics education» and to defend the idea that mathematics education has constituted a privileged research theme within the field of comparative historical studies. To achieve these aims, the text includes references to a review of the literature concerning comparative studies, the analysis of two fundamental moments focused on attempts to internationalize the mathematics curriculum, both of which occurred during the 20th century, and, to end, a case study emanating from an international cooperation between researchers in Brazil and Portugal.

  13. Positron emission tomography

    International Nuclear Information System (INIS)

    Iio, Masahiro

    1982-01-01

    Utilization of positron emission tomography was reviewed in relation to construction and planned construction of small-size medical cyclotrons, planned construction of positron cameras and utilization of short-lived radionuclides. (Chiba, N.)

  14. Positron emission tomography/computed tomography imaging and rheumatoid arthritis.

    Science.gov (United States)

    Wang, Shi-Cun; Xie, Qiang; Lv, Wei-Fu

    2014-03-01

    Rheumatoid arthritis (RA) is a phenotypically heterogeneous, chronic, destructive inflammatory disease of the synovial joints. A number of imaging tools are currently available for evaluation of inflammatory conditions. By targeting the upgraded glucose uptake of infiltrating granulocytes and tissue macrophages, positron emission tomography/computed tomography with fluorine-18 fluorodeoxyglucose ((18) F-FDG PET/CT) is available to delineate inflammation with high sensitivity. Recently, several studies have indicated that FDG uptake in affected joints reflects the disease activity of RA. In addition, usage of FDG PET for the sensitive detection and monitoring of the response to treatment has been reported. Combined FDG PET/CT enables the detailed assessment of disease in large joints throughout the whole body. These unique capabilities of FDG PET/CT imaging are also able to detect RA-complicated diseases. Therefore, PET/CT has become an excellent ancillary tool to assess disease activity and prognosis in RA. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  15. The possibility of identifying the spatial location of single dislocations by topo-tomography on laboratory setups

    Energy Technology Data Exchange (ETDEWEB)

    Zolotov, D. A., E-mail: zolotovden@crys.ras.ru; Buzmakov, A. V.; Elfimov, D. A.; Asadchikov, V. E.; Chukhovskii, F. N. [Russian Academy of Sciences, Shubnikov Institute of Crystallography, Federal Scientific Research Centre “Crystallography and Photonics,” (Russian Federation)

    2017-01-15

    The spatial arrangement of single linear defects in a Si single crystal (input surface (111)) has been investigated by X-ray topo-tomography using laboratory X-ray sources. The experimental technique and the procedure of reconstructing a 3D image of dislocation half-loops near the Si crystal surface are described. The sizes of observed linear defects with a spatial resolution of about 10 μm are estimated.

  16. Experimental investigation of bone mineral density in Thoroughbreds using quantitative computed tomography

    Science.gov (United States)

    YAMADA, Kazutaka; SATO, Fumio; HIGUCHI, Tohru; NISHIHARA, Kaori; KAYANO, Mitsunori; SASAKI, Naoki; NAMBO, Yasuo

    2015-01-01

    ABSTRACT Bone mineral density (BMD) is one of the indications of the strength and health. BMD measured by quantitative computed tomography (QCT) was compared with that measured by dual energy X-ray absorptiometry (DXA) and radiographic bone aluminum equivalence (RBAE). Limbs were removed from horses that had been euthanized for reasons not associated with this study. Sixteen limbs (left and right metacarpals and metatarsals) from 4 horses were used to compare BMD as measured by QCT with those measured by DXA and RBAE. There was a strong correlation between BMD values measured by QCT and those measured by DXA (R2=0.85); correlation was also observed between values obtained by QCT and those obtained by RBAE (R2=0.61). To investigate changes in BMD with age, 37 right metacarpal bones, including 7 from horses euthanized because of fracture were examined by QCT. The BMD value of samples from horses dramatically increased until 2 years of age and then plateaued, a pattern similar to the growth curve. The BMD values of bone samples from horses euthanized because of fracture were within the population range, and samples of morbid fracture were not included. The relationship between BMD and age provides a reference for further quantitative studies of bone development and remodeling. Quantitative measurement of BMD using QCT may have great potential for the evaluation of bone biology for breeding and rearing management. PMID:26435681

  17. A scaled experimental study of control blade insertion dynamics in Pebble-Bed Fluoride-Salt-Cooled High-Temperature Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Buster, Grant C., E-mail: grant.buster@gmail.com; Laufer, Michael R.; Peterson, Per F.

    2016-07-15

    Highlights: • A granular dynamics scaling methodology is discussed. • Control blade insertion in a representative pebble-bed core is experimentally studied. • Control blade insertion forces and pebble displacements are experimentally measured. • X-ray tomography techniques are used to observe pebble displacement distributions. - Abstract: Direct control element insertion into a pebble-bed reactor core is proposed as a viable control system in molten-salt-cooled pebble-bed reactors. Unlike helium-cooled pebble-bed reactors, this reactor type uses spherical fuel elements with near-neutral buoyancy in the molten-salt coolant, thus reducing contact forces on the fuel elements. This study uses the X-ray Pebble Bed Recirculation Experiment facility to measure the force required to insert a control element directly into a scaled pebble-bed. The required control element insertion force, and therefore the contact force on fuel elements, is measured to be well below recommended limits. Additionally, X-ray tomography is used to observe how the direct insertion of a control element physically displaces spherical fuel elements. The tomography results further support the viability of direct control element insertion into molten-salt-cooled pebble-bed reactor cores.

  18. The added value of 18F-fluorodeoxyglucose positron emission tomography computed tomography in patients with neck lymph node metastases from an unknown primary malignancy.

    Science.gov (United States)

    Prowse, S J B; Shaw, R; Ganeshan, D; Prowse, P M; Hanlon, R; Lewis-Jones, H; Wieshmann, H

    2013-08-01

    The search for a primary malignancy in patients with a metastatic cervical lymph node is challenging yet ultimately of utmost clinical importance. This study evaluated the efficacy of positron emission tomography computed tomography in detecting the occult primary, within the context of a tertiary referral centre head and neck cancer multidisciplinary team tumour board meeting. Thirty-two patients (23 men and 9 women; mean and median age, 61 years) with a metastatic cervical lymph node of unknown primary origin, after clinical examination and magnetic resonance imaging, underwent positron emission tomography computed tomography. The primary tumour detection rate was 50 per cent (16/32). Positron emission tomography computed tomography had a sensitivity of 94 per cent (16/17) and a specificity of 67 per cent (10/15). Combining these results with those of 10 earlier studies of similar patients gave an overall detection rate of 37 per cent. Positron emission tomography computed tomography has become an important imaging modality. To date, it has the highest primary tumour detection rate, for head and neck cancer patients presenting with cervical lymph node metastases from an unknown primary.

  19. The development of an x-ray computerized tomography (CT) experimental system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, G.N.; Kijek, M.M.; Millar, J.J. [Royal Melbourne Inst. of Tech., VIC (Australia)

    1993-12-31

    This paper describes a prototype experimental CT system that has been recently developed at Applied Physics, RMIT/ Physics, La Trobe UCNV. The system incorporates the scanning mode of the first generation CAT-scanner and is designed to perform the scanning of small objects. A microcomputer is used to control the scanning motions and data collection. The performance of the system was examined by scanning a ball-point pen. 8 refs., 4 figs.

  20. The development of an x-ray computerized tomography (CT) experimental system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, G N; Kijek, M M; Millar, J J [Royal Melbourne Inst. of Tech., VIC (Australia)

    1994-12-31

    This paper describes a prototype experimental CT system that has been recently developed at Applied Physics, RMIT/ Physics, La Trobe UCNV. The system incorporates the scanning mode of the first generation CAT-scanner and is designed to perform the scanning of small objects. A microcomputer is used to control the scanning motions and data collection. The performance of the system was examined by scanning a ball-point pen. 8 refs., 4 figs.