  1. AIDS related thoracic lymphoma: evaluation by computed tomography; Linfoma toracico na sindrome da imunodeficiencia adquirida: avaliacao por tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Siciliano, Antonio Alexandre de Oliveira [Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil). Servico de Radiodiagnostico; Marchiori, Edson [Universidade Federal, Rio de Janeiro, RJ (Brazil). Curso de Pos-graduacao em Radiologia

    2000-02-01

    The authors reviewed five cases of patients with acquired immunodeficiency syndrome (AIDS) related lymphoma to describe the thoracic findings on computed tomography. The patients were followed at Hospital Universitario Clementino Fraga Filho, Hospital Universitario Antonio Pedro and Hospital da Lagoa, from November, 1989 to March 1998. Epidemiological, clinical and pathological data from these patients were quiet variable and pulmonary nodules and masses, hilar and mediastinal lymphadenopathy, and thoracic wall masses were observed. AIDS related lymphomas involving the chest are pleomorphic and most commonly extranodal. (author)

  2. Evaluation of the absorbed dose in odontological computerized tomography; Avaliacao da dose absorvida em tomografia computadorizada odontologica

    Energy Technology Data Exchange (ETDEWEB)

    Legnani, Adriano; Schelin, Hugo R.; Rocha, Anna Silvia P.S. da, E-mail: schelin@utfpr.edu.b, E-mail: anna@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Khoury, Helen J., E-mail: khoury@ufpe.b [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2011-10-26

    This paper evaluated the absorbed dose at the surface entry known as 'cone beam computed tomography' (CBCT) in odontological computerized tomography. Examination were simulated with CBCT for measurements of dose. A phantom were filled with water, becoming scatter object of radiation. Thermoluminescent dosemeters were positioned on points correspondent to eyes and salivary glands

  3. Evaluation of the absorbed dose in odontological computerized tomography; Avaliacao da dose absorvida em tomografia computadorizada odontologica

    Energy Technology Data Exchange (ETDEWEB)

    Legnani, Adriano; Schelin, Hugo R; Rocha, Anna Silvia P.S. da, E-mail: schelin@utfpr.edu.b, E-mail: anna@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Khoury, Helen J., E-mail: khoury@ufpe.b [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2011-10-26

    This paper evaluated the absorbed dose at the surface entry known as 'cone beam computed tomography' (CBCT) in odontological computerized tomography. Examination were simulated with CBCT for measurements of dose. A phantom were filled with water, becoming scatter object of radiation. Thermoluminescent dosemeters were positioned on points correspondent to eyes and salivary glands

  4. Density evaluation by computerized tomography in plain soils over different manipulation systems; Avaliacao da densidade pelo metodo da tomografia computadorizada de um planossolo sob diferentes sistemas de manejo

    Energy Technology Data Exchange (ETDEWEB)

    Pedrotti, Alceu [Lavras Univ., MG (Brazil). Dept. de Ciencia do Solo; Pauletto, Eloy Antonio [Pelotas Univ., RS (Brazil). Dept. de Solos; Crestana, Silvio [Empresa Brasileira de Pesquisa Agropecuaria (EMBRAPA), Sao Carlos, SP (Brazil). Centro Nacional de Pesquisa e Desenvolvimento de Instrumentacao Agropecuaria (CNPDIA)

    1996-08-01

    The objective of this paper is the evaluation of a plain soil density in different culture systems determined by X ray computerized tomography.It was observed a larger variation in densities in soils profiles analysed. The identification of layers is better utilising computerized tomography than others technic 1 fig.

  5. Quantitative computed tomography as a test of endurance for evaluation of bony plates; Utilizacao da tomografia computadorizada quantitativa como teste de resistencia para avaliacao de placas osseas

    Energy Technology Data Exchange (ETDEWEB)

    Melo Filho, E.V.; Costa, L.A.V.S.; Oliveira, D.C. [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil); Freitas, P.M.C. [Escola de Veterinaria - Universidade Federal de Minas Gerais - Belo Horizonte, MG (Brazil); Teixeira, M.W.; Costa, F.S. [Universidade Federal Rural de Pernambuco - Recife, PE (Brazil)

    2012-06-15

    Quantitative computed tomography was used to determine the radiodensity of bony plates. The CT scans provided information regarding radiodensity of bony plates and allowed to verify the uniformity of bone mineral density in their scope. The proposed methodology should be considered as another tool for determining the resistance of these biomaterials. (author)

  6. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography; Avaliacao dos diametros normais da aorta toracica e abdominal pela tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, Claudio Luiz

    1995-07-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  7. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography; Avaliacao dos diametros normais da aorta toracica e abdominal pela tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, Claudio Luiz

    1995-07-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  8. Avaliacao de projeto de promocao da saude para adolescentes

    Directory of Open Access Journals (Sweden)

    Jovino Oliveira Ferreira

    2013-06-01

    Full Text Available OBJETIVO: Avaliar programa de promoção de atividade física e de escolhas alimentares entre adolescentes. MÉTODOS: Estudo transversal realizado com 911 adolescentes de 13 a 18 anos de idade, de escolas públicas de Goiânia, GO, em 2010. Os participantes foram divididos em dois grupos: intervenção (escolas participantes do Projeto Viver Saudável e controle. Foram considerados como atividade física: deslocamento, aulas de educação física na escola, atividade física fora da escola e no lazer. Foram definidos como ativos aqueles que acumularam 300 ou mais minutos por semana. Quanto às escolhas alimentares, foi classificado como adequado o consumo de alimentos protetores em cinco ou mais dias da semana. Foram realizadas análises estatísticas com teste de Qui-quadrado de Pearson. RESULTADOS: A maioria dos adolescentes foi identificada como inativos ou insuficientemente ativos, com 65,7% no grupo intervenção e 65,2% no grupo controle, sem diferenças significativas entre os grupos e com prevalência maior entre o sexo feminino. Pouco mais da metade dos adolescentes consumiam alimentos protetores da saúde em cinco ou mais dias da semana, sendo 56,6% e 50,4%, respectivamente, nos grupos intervenção e controle (p = 0,373. CONCLUSÕES: A ausência de diferenças quanto a escolhas alimentares e prática de atividade física entre os grupos intervenção e controle indica que o projeto Viver Saudável precisa ser reavaliado visando melhorar a efetividade no cumprimento dos seus objetivos.

  9. Image quality and volume computed tomography air kerma index (C{sub vol}) evaluation in Recife; Avaliacao da qualidade de imagem e do indice volumetrico de Kerma ar em tomografia computadorizada (C{sub vol}) em Recife

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Marcos Ely Almeida

    2008-07-01

    The Computed Tomography (CT) is an important diagnostic imaging method, widely used. However, in spite of all the advantages and technologic advances within the CT scanners, the tomographic procedures result in high absorbed doses to patients. The main objective of this work was to perform a dosimetric study of CT scanners located at Recife and to evaluate the image quality on CT examinations in these equipment. The volume CT air kerma index (C{sub VOL}) and air kerma length product (P{sub KL,CT}) were estimated. These values were calculated using normalized weighted air kerma indexes in CT standard dosimetry phantoms ({sub n}C{sub W}), supplied by ImPACT group for several CT scanners, and the scan parameters of routine head, routine chest and hi-resolution chest CT exams performed at 20 institutions. The irradiation parameters of 15 adult patients for each CT procedure were registered at six participating centres, at which the phantom from the American College of Radiology (ACR) CT accreditation protocol was used for the image quality measurements. For routine head exams, the C{sub VOL} values varied between 12 and 58 mGy (at the posterior fossa) and 15 to 58 mGy (at the cerebrum) and the P{sub KL,CT}, from 150 to 750 mGy{center_dot}cm. The C{sub VOL} values for routine chest procedures varied from 3 to 26 mGy and the P{sub KL,CT}, between 120 and 460 mGy{center_dot}cm. In relation to Hi-resolution chest exams, C{sub VOL} values were from 1.0 to 2.7 mGy and the P{sub KL,CT} values varied between 24 and 67 mGy{center_dot}cm. The image quality evaluations results showed that almost all scanners presented at least one inadequacy. One of the equipment presented faults at 70% of the tests. With regard to the image noise, only two scanners presented acceptable results. From these results, it is possible to conclude that the volume CT air kerma index values are lower than the European reference levels. However, the image quality of these CT scanners does not attend the

  10. Avaliacao de interacoes medicamentosas potenciais em prescricoes da atencao primaria de Vitoria da Conquista (BA), Brasil

    OpenAIRE

    Danyllo Fabio Lessa Leao; Cristiano Soares de Moura; Danielle Souto de Medeiros

    2014-01-01

    As interações medicamentosas são fatores de risco para a ocorrência de reações adversas a medicamentos. Este estudo teve o objetivo de avaliar as interações medicamentosas potenciais em prescrições da atenção primária de Vitória da Conquista (BA), visando preencher a lacuna de conhecimento sobre essa temática no Brasil. Foram coletadas informações sobre diversas variáveis de prescrições oriundas da atenção primária e as interações medicamentosas avaliadas a partir dos bancos de dados do Medsc...

  11. Instrumentos em Lingua Brasileira de Sinais para avaliacao da qualidade de vida da populacao surda

    Directory of Open Access Journals (Sweden)

    Neuma Chaveiro

    2013-06-01

    Full Text Available OBJETIVO: Construir a versão em Língua Brasileira de Sinais dos instrumentos WHOQOL-BREF e WHOQOL-DIS para avaliar a qualidade de vida da população surda brasileira. MÉTODOS: Utilizou-se metodologia proposta pela Organização Mundial da Saúde (WHOQOL-BREF e WHOQOL-DIS para a construção dos instrumentos adaptados para população surda em Língua Brasileira de Sinais (Libras. A pesquisa para execução do instrumento consistiu de 13 etapas: 1 criação do sinal qualidade de vida; 2 desenvolvimento das escalas de respostas em Libras; 3 tradução por um grupo bilíngue; 4 versão reconciliadora; 5 primeira retrotradução; 6 produção da versão em Libras a ser disponibilizada aos grupos focais; 7 realização dos grupos focais; 8 revisão por um grupo monolíngue; 9 revisão pelo grupo bilíngue; 10 análise sintática/semântica e segunda retrotradução; 11 reavaliação da retrotradução pelo grupo bilíngue; 12 filmagem da versão para o software; 13 desenvolvimento do software WHOQOL-BREF e WHOQOL-DIS em Libras. RESULTADOS: Características peculiares da cultura da população surda apontaram a necessidade de adaptações na metodologia de aplicação de grupos focais quando compostos por pessoas surdas. As convenções ortográficas da escrita das línguas sinalizadas não estão consolidadas, o que trouxe dificuldades em registrar graficamente as etapas de tradução. As estruturas linguísticas que causaram maiores problemas de tradução foram as que incluíram expressões idiomáticas do português, muitas sem conceitos equivalentes entre o português e a Libras. Foi possível construir um software do WHOQOL-BREF e WHOQOL-DIS em Libras. CONCLUSÕES: O WHOQOL-BREF e o WHOQOL-DIS em Libras possibilitarão que os surdos se expressem autonomamente quanto a sua qualidade de vida, o que permitirá investigar com maior precisão essas questões.

  12. Avaliacao de interacoes medicamentosas potenciais em prescricoes da atencao primaria de Vitoria da Conquista (BA, Brasil

    Directory of Open Access Journals (Sweden)

    Danyllo Fabio Lessa Leao

    2014-01-01

    Full Text Available As interações medicamentosas são fatores de risco para a ocorrência de reações adversas a medicamentos. Este estudo teve o objetivo de avaliar as interações medicamentosas potenciais em prescrições da atenção primária de Vitória da Conquista (BA, visando preencher a lacuna de conhecimento sobre essa temática no Brasil. Foram coletadas informações sobre diversas variáveis de prescrições oriundas da atenção primária e as interações medicamentosas avaliadas a partir dos bancos de dados do Medscape e Micromedex(r. Verificou-se ainda a frequência de polifarmácia e associação desta com a ocorrência de interações medicamentosas. Os resultados mostraram frequência de 48,9% de interações medicamentosas, 74,9% delas de gravidade moderada ou maior, e 8,6% de prescrições em polifarmácia que, em teste qui-quadrado, mostrou associação positiva com ocorrência de interações medicamentosas potenciais (p < 0,001. As prescrições oriundas da atenção primária de Vitória da Conquista (BA apresentaram uma alta frequência de interações medicamentosas, porém faz-se necessária a análise de outros fatores de risco para ocorrência destas nesse nível de atenção à saúde.

  13. Computed tomography evaluation of mast cell tumours; Avaliacao por tomografia computadorizada dos mastocitomas

    Energy Technology Data Exchange (ETDEWEB)

    Lorigados, Carla Aparecida Batista; Matera, Julia Maria; Macedo, Thais; Pinto, Ana Carolina Brandao Fonseca, E-mail: clorigados@usp.br [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Cirurgia

    2012-07-01

    The mast cell tumours are common tumours of the canine skin. Computed tomography (CT) has assumed an important role in tumours evaluation and staging. The aim of this study was to evaluate the role of CT as a method of assessing characteristics of mast cell tumors. Ten dogs with mast cell tumor were evaluated. CT was performed before and after the intravenous injection of hydro soluble ionic iodine. Attenuation, contrast enhancement, cleavage with adjacent tissues and the unidimensional measurement of each lesion was determined in it maximum diameter, in transversal plane. Concerning the attenuation characteristic, 50% were homogeneous and 50% heterogeneous. The contrast enhancement was homogeneous in 50% of cases, heterogeneous in 40% and peripheral in 10%. Fifty percent of the tumours showed loss of plane of cleavage and 30% partial loss. This information can help in directing the patients that will be undergoing chemotherapy or surgery. (author)

  14. Dose assessment in pediatric computerized tomography; Avaliacao de doses em tomografia computadorizada pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Vilarinho, Luisa Maria Auredine Lima

    2004-07-01

    The objective of this work was the evaluation of radiation doses in paediatric computed tomography scans, considering the high doses usually involved and the absence of any previous evaluation in Brazil. Dose values were determined for skull and abdomen examinations, for different age ranges, by using the radiographic techniques routinely used in the clinical centers investigated. Measurements were done using pencil shape ionization chambers inserted in polymethylmethacrylate (PMMA) phantoms. These were compact phantoms of different diameters were specially designed and constructed for this work, which simulate different age ranges. Comparison of results with published values showed that doses were lower than the diagnostic reference levels established to adults exams by the European Commission. Nevertheless, doses in paediatric phantoms were higher than those obtained in adult phantoms. The paediatric dose values obtained in Hospitals A and B were lower than the reference level (DRL) adopted by SHIMPTON for different age ranges. In the range 0 - 0.5 year (neonatal), the values of DLP in Hospital B were 94 por cent superior to the DRL For the 10 years old children the values of CTDI{sub w} obtained were inferior in 89 por cent for skull and 83 por cent for abdomen examinations, compared to the values published by SHRIMPTON and WALL. Our measured CTDI{sub w} values were inferior to the values presented for SHRIMPTON and HUDA, for all the age ranges and types of examinations. It was observed that the normalized dose descriptors values in children in the neonatal range were always superior to the values of doses for the adult patient. In abdomen examinations, the difference was approximately 90% for the effective dose (E) and of 57%.for CTDI{sub w} . (author)

  15. Avaliacao da Relacao entre a Doenca Hepatica Nao Gordurosa e CAD utilizando TCMF

    Directory of Open Access Journals (Sweden)

    Duran Efe

    2014-01-01

    Full Text Available Fundamento: Alguns fatores de risco para a aterosclerose são acompanhados pela doença hepática gordurosa não alcoólica (DHGNA. Desejamos usar a tomografia computadorizada multi-fatias (TCMF como a técnica para encontrar relação entre a DHGNA e a doença arterial coronariana (DAC. Objetivo: A relação entre a DHGNA e a DAC foi investigada através de TCMF. Métodos: Um total de 372 indivíduos com ou sem sintomas cardíacos, que foram submetidos à angiografia por TCMF, foram incluídos no estudo. Os pacientes foram divididos em dois grupos, de acordo com a presença da DHGNA. Os segmentos arteriais coronarianos foram avaliados visualmente via angiografia por TCMF. Com base no grau de estenose arterial coronariana, aqueles com placas ausentes ou mínimas foram considerados como normais, enquanto aqueles que apresentavam estenose de menos do que 50% e no mínimo uma placa foram considerados como portadores da doença arterial coronariana não obstrutiva (não-obsDAC. Os pacientes que apresentaram no mínimo uma placa e estenose arterial coronariana de 50% ou mais foram considerados como portadores de doença arterial coronariana obstrutiva (obsDAC. A DHGNA foi determinada de acordo com o protocolo de TCMF, utilizando a densidade hepática. Resultados: De acordo com a densidade hepática, o número de pacientes com doença hepática gordurosa não alcoólica (grupo 1 foi de 204 (149 homens, 54,8% e com fígado normal (grupos 2 foi de 168 (95 homens, 45.2%. Houve 50 (24,5% não-obsDAC e 57 (27,9% casos de obsDAC no Grupo 1, e 39 (23,2% não-obsDAC e 23 (13,7% casos de obsDAC no Grupo 2. Conclusões: O presente estudo utilizando TCMF demonstrou que a frequência da doença arterial coronariana em pacientes com NAFDL foi significativamente superior do que nos pacientes em NAFDL.

  16. Avaliacao da seguranca de diferentes doses de suplementos de acido folico em mulheres do Brasil

    Directory of Open Access Journals (Sweden)

    Quenia dos Santos

    2013-10-01

    Full Text Available OBJETIVO Avaliar a distribuição da ingestão de ácido fólico e a segurança de diferentes doses de suplementos em mulheres em idade reprodutiva. MÉTODOS Foram utilizados dados de consumo a partir de dois dias não consecutivos de registro alimentar de 6.837 mulheres em idade reprodutiva (19 a 40 anos participantes do Inquérito Nacional de Alimentação, módulo da Pesquisa de Orçamentos Familiares 2008-2009. Médias e percentis de consumo habitual de folato natural e ácido fólico foram estimados utilizando o método do National Cancer Institute . Cinco cenários foram simulados somando-se diferentes doses diárias de fortificação (400 mcg, 500 mcg, 600 mcg, 700 mcg e 800 mcg ao ácido fólico oriundo dos alimentos consumidos pelas mulheres. Comparou-se o total de ácido fólico (dieta + suplemento com o nível máximo de ingestão tolerável (UL = 1.000 mcg para definir a dose segura de suplementação. RESULTADOS Mulheres com ingestão habitual de ácido fólico acima do nível máximo de ingestão tolerável foram observadas para doses de suplemento de 800 mcg (7,0% das mulheres. Abaixo desse valor, qualquer dose de suplementação mostrou-se segura. CONCLUSÕES O uso de suplementos de até 700 mcg de ácido fólico mostrou-se seguro.

  17. Radiological evaluation of the cranio vertebral junction; Avaliacao radiologica da transicao cranio-vertebral

    Energy Technology Data Exchange (ETDEWEB)

    Mello, Silvia Marcal Benicio de; Haetinger, Rainer Guilherme [Med Imagem - Beneficiencia Portuguesa de Sao Paulo, SP (Brazil). Setor de Cabeca e Pescoco]. E-mail: sbm@uol.com.br; Schettini, Marianna Cunha; Lima, Sergio Santos [Med Imagem - Beneficiencia Portuguesa de Sao Paulo, SP (Brazil); Mourao, Maria Lucia; Mendonca, Renato Adam [Med Imagem - Beneficiencia Portuguesa de Sao Paulo, SP (Brazil). Setor de Neuroradiologia

    2005-04-15

    The cranio vertebral junction (CVJ) comprises the occiput, atlas, their joints and ligaments. Besides conventional x-rays other imaging methods are need for the assessment of CVJ including high resolution computerized tomography (CT) and magnetic resonance imaging (MRI) which provide specific parameters such as field of view, slice thickness and incremental movement of the patient. A dynamic study is also important to assess the stability of the cranio vertebral junction and the effect upon the bulbomedullary junction. The aim of this study is to review the techniques used in the evaluation of the CVJ, the semiological parameters, and the most frequent disorders affecting this region. We review the literature and present conventional x-ray, CT and MRI images from the didactic file of the Radiology service 'Med Imagem - Beneficiencia Portuguesa de Sao Paulo, SP, Brazil, of cases with normal anatomy and the main congenital and acquired disorders of the CVJ. In daily practice, CVJ disorders are diagnoses using CT and MRI scans of the head and cervical spine. It is essential to be familiar with these conditions in order to preform specific tests which will allow a detailed study of the CVJ, thus providing the basis for the treatment, whenever indicated. (author)

  18. Ablation of burned skin with ultra-short pulses laser to promote healing: evaluation by optical coherence tomography, histology, {mu}ATR-FTIR and Nonlinear Microscopy; Ablacao de pele queimada com laser de pulsos ultra-curtos para promocao da cicatrizacao: avaliacao por tomografia por coerencia optica, histologia, {mu}ATR-FTIR e microscopia nao-linear

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Moises Oliveira dos

    2012-07-01

    Burns cause changes in the anatomical structure of the skin associated with trauma. The severity of the burn injury is divided into first, second and third-degree burns. The third-degree burns have been a major focus of research in search of more conservative treatments and faster results in repair for a functional and cosmetically acceptable. The conventional treatment is the use of topical natural or synthetic skin graft. An alternative therapy is the laser ablation process for burned tissue necrosis removal due to the no mechanical contact, fast application and access to difficult areas. The purpose of this study is to evaluate the feasibility of using high intensity femtosecond lasers as an adjunct treatment of burned patients. For this study, 65 Wistar rats were divided into groups of five animals: healthy skin, burned skin, two types of treatment (surgical debridement or femtosecond laser ablation) and four different times in the healing process monitoring. Three regions of the back of the animals were exposed to steam source causing third-degree burn. On the third day after the burn, one of the regions was ablated with high intensity ultrashort laser pulses ({lambda} = 785 nm, 90 fs, 2 kHz and 10 {mu}J/ pulse), the other received surgical debridement, and the last was considered the burn control. The regions were analyzed by optical coherence tomography (OCT), histology, attenuated total reflectance infrared spectroscopy using Fourier transform ({mu}-ATR-FTIR), two-photon excitation fluorescence microscopy (TPEFM) and second harmonic generation technique (SHG) on days 3, 5, 7 and 14 pos-treatments. The results showed that with the laser irradiation conditions used it was possible to remove debris from third degree burn. The techniques used to characterize the tissue allowed to verify that all treatments promoted wound healing. On the fourteenth day, the regeneration curve showed that the attenuation coefficient of laser ablated tissue converges to the values

  19. Unilateral pulmonary veins atresia: evaluation by computed tomography; Atresia unilateral das veias pulmonares: avaliacao por tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Eifer, Diego Andre; Arsego, Felipe Veras, E-mail: felipesoarestorres@gmail.com [Hospital de Clinicas de Porto Alegre (HCPA), RS (Brazil). Serv. de Radiologia; Torres, Felipe Soares [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Escola de Medicina

    2013-11-15

    Unilateral pulmonary vein atresia is a rare congenital condition. In addition to cardiac malformations or pulmonary hypertension, patients may present with recurrent pulmonary infections or hemoptysis in childhood or adolescence. The authors report a case where the typical findings of such condition were observed at computed tomography in an adult patient. (author)

  20. Pulmonary leukemic involvement: high-resolution computed tomography evaluation; Comprometimento pulmonar nas leucemias: avaliacao por tomografia computadorizada de alta resolucao

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Ana Paola de [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Programa de Pos-graduacao em Radiologia; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Souza, Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Dept. de Radiologia

    2004-12-01

    Objective: To evaluate the role of high-resolution computed tomography (HRCT) in patients with leukemia and pulmonary symptoms, to establish the main patterns and to correlate them with the etiology. Materials and Methods: This is a retrospective study of the HRCT of 15 patients with leukemia and pulmonary symptoms. The examinations were performed using a spatial high-resolution protocol and were analyzed by two independent radiologists. Results: The main HRCT patterns found were ground-glass opacity (n=11), consolidation (n=9), airspace nodules (n=3), septal thickening (n=3), tree-in-bud pattern (n=3), and pleural effusion (n=3). Pulmonary infection was the most common finding seen in 12 patients: bacterial pneumonia (n=6), fungal infection (n = 4), pulmonary tuberculosis (n=1) and viral infection (n=1). Leukemic pleural infiltration (n=1), lymphoma (n=1) and pulmonary hemorrhage (n=1) were detected in the other three patients. Conclusion: HRCT is an important tool that may suggest the cause of lung involvement, its extension and in some cases to guide invasive procedures in patients with leukemia. (author)

  1. Leitura rapida do KDIGO 2012: Diretrizes para avaliacao e manuseio da doenca renal cronica na pratica clinica

    Directory of Open Access Journals (Sweden)

    Gianna Mastroianni Kirsztajn

    2014-03-01

    Full Text Available Os autores desta "leitura rápida" apresentam os dados que consideraram mais relevantes na versão 2012 do KDIGO referente à avaliação e manuseio da doença renal crônica. Não se trata da opinião dos autores, mas sim de uma apresentação mais concisa das diretrizes, que podem ser úteis na prática clínica.

  2. Avaliacao da espessura medio-intimal em pacientes com doenca renal cronica nao dialitica: estudo prospectivo de 24 meses

    Directory of Open Access Journals (Sweden)

    Andrea Gaspar Marcos

    2014-03-01

    Full Text Available Introdução: O aumento da espessura média-intimal (EMI avaliada por ultrassom é um preditor de risco cardiovascular na população geral. Porém, em pacientes com doença renal crônica nos estágios iniciais, essa associação ainda não está bem estabelecida. Objetivo: Avaliar a associação EMI com a ocorrência de eventos cardiovasculares e mortalidade em pacientes nos estágios iniciais da doença renal crônica. Métodos: A análise post hoc de uma coorte de pacientes nos estágios 2-4 da DRC. Foram avaliados dados laboratoriais, ultrassom da artéria carótida e tomografia coronariana no início do estudo e a ocorrência de óbito, em seguimento por 24 meses. Resultados: Um total de 117 pacientes (57 ± 11 anos, 61% sexo masculino foram avaliados. A taxa de filtração glomerular foi 36 ± 17 mL/min, 96% dos pacientes eram hipertensos, 23% diabéticos e 27% obesos. Calcificação arterial coronariana esteve presente em 48% dos pacientes, sendo mais prevalente em pacientes nos estágios mais avançados da DRC (p = 0,02. EMI foi 0,6 mm (0,4-0,7 mm. Comparado aos pacientes com EMI < 0,6mm, aqueles com EMI ≥ 0,6 mm eram mais velhos (p = 0,001, apresentavam maior prevalência do sexo masculino (p = 0,001, menor taxa de filtração glomerular (p = 0,01 e maior proporção de pacientes com calcificação (p = 0,001. Não foi observada relação entre a espessura média-intimal e a ocorrência de evento cardiovascular e óbito. Conclusão: A espessura médio-intimal em pacientes DRC se associou à calcificação coronariana, mas não à ocorrência de eventos cardiovasculares e óbito, em um seguimento de 24 meses.

  3. Assessment of natural radioactivity of sands in beaches from Great Vitoria, ES, Brazil; Avaliacao da radioatividade natural em areias das praias da Grande Vitoria, ES

    Energy Technology Data Exchange (ETDEWEB)

    Aquino, Reginaldo Ribeiro de

    2010-07-01

    In this work the concentrations of natural radionuclides {sup 226}Ra, {sup 232}Th and {sup 40}K were determined in superficial sand samples for 16 locations throughout the coast of the Great Victory, metropolitan region of the state of Espirito Santo, Southeast of Brazil. The assessed beaches were Manguinhos and Jacaraipe in Serra county, Camburi, Praia do Canto and Curva da Jurema in Vitoria county, Praia da Costa and Itapua in Vila Velha county, Setibao, Setibinha, Praia do Morro, Praia das Castanheiras and Areia Preta in Guarapari county and sand of the Paulo Cesar Vinha Reserve also located in Guarapari county. Three sand samples of each beach were sealed in 100 mL high density polyethylene flasks. After approximately 4 weeks in order to reach secular equilibrium in the {sup 238}U and {sup 2}'3{sup 2}Th series, the samples were measured by high resolution gamma spectrometry and the spectra analyzed with the WinnerGamma software. The self absorption correction was performed for all samples. The {sup 226}Ra concentration was determined from the weighted average concentrations of {sup 214}Pb and {sup 21}'4Bi, the {sup 232}Th concentration was determined from the weighted average concentrations of {sup 228}Ac, {sup 2}'1{sup 2}Pb and {sup 212}Bi and the concentration of {sup 40}K is determined by its single gamma transition of 1460 keV. The radium equivalent concentration and the external hazard index where obtained from the concentrations of {sup 226}Ra, {sup 232}Th and {sup 4}'0K. {sup 226}Ra concentrations show values varying from 3 +- 1 Bq.kg-1 to 738 +- 38 Bq.kg{sup -1}, with the highest values for the central locality of the Camburi beach. {sup 232}Th concentrations show values varying from 7 +- 3 Bq.kg{sup -1} to 7422 +- 526 Bq.kg{sup -1}, with the highest values for Areia Preta beach. {sup 40}K concentrations show values varying from 14 +- 6 Bq.kg{sup -1} to 638 +- 232 Bq.kg{sup -1}, with the highest values for Areia Preta beach

  4. Method of evaluation of diagnostics reference levels in computerized tomography; Metodo de avaliacao de niveis de referencia de radiodiagnostico em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  5. Assessment in dogs tympanic bulla, through virtual tomographic endoscopy; Avaliacao de bulas timpanicas em caes, por meio da endoscopia tomografica virtual

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Luciana Carandina da; Sabino, Emanuelle Guidugli, E-mail: lucianacarandina@uol.com.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria. Dept. de Reproducao Animal e Radiologia Veterinaria; Vulcano, Luiz Carlos; Machado, Vania Maria de Vasconcelos [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria

    2012-07-01

    Dogs usually have problems related to the auditory canal. For the diagnosis of these pathologies, it is necessary a physical examination and, in some cases radiographic examination and computed tomography. The tympanic bulla is not easily visualized radiographically, since there is many structures of the brain overlaying the image obtained. The computed tomography has been the technique of choice to assess this structure faithfully. A new alternative assessment of the tympanic bulla is tomographic virtual endoscopy, which allows an improvement of the image obtained through the virtual tomographic technique. This paper provides information on the use of computed tomography, and a new technique, tomographic virtual endoscopy, in order to make the improvement of these techniques, and prove the reliability of these changes in the diagnosis of ear canals of dogs. Therefore, we performed the computed tomography of the tympanic bulla on healthy animals, and later performed image reconstruction in three-dimensional (3D) mode for virtual endoscopy. (author)

  6. Evaluation of uniformity and noise consistency test in computerized tomography; Avaliacao do teste de constancia de uniformidade e ruido em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Garrafiel, Fabricio N.; Lykawka, Rochelle; Bacelar, Alexandre; Anes, Mauricio [Hospital de Clinicas de Porto Alegre (HCPA), Porto Alegre, RS (Brazil); Alva-Sanchez, Mirko S.; Pianoschi, Thatiane [Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), Porto Alegre, RS (Brazil)

    2016-07-01

    The quality control in computed tomography (CT) includes constancy tests concerning CT number measured in a water tank and its response as uniformity, noise and accuracy. Differences to It's performance limits and frequency established by the national legislation and the manufacturers are well known. The objective of this study was to evaluate these tests proceeding the periodicity of national legislation. The tests were conducted over a three equipment of different manufacturers. Each equipment has acquisition parameters and specific phantoms. The equipment presented adequate performance and consistency when compared their results to the limits determined by manufacturers and national legislation. Thus, it is important to evaluate these differences and tailor the testing protocols to meet the established quality requirements. (author)

  7. Computed tomography of mast cell tumors in dogs: assessment before and after chemotherapy; Tomografia computadorizada de mastocitomas em caes: avaliacao pre e pos-tratamento quimioterapico

    Energy Technology Data Exchange (ETDEWEB)

    Lorigados, Carla A.B.; Matera, Julia Maria; Pinto, Ana Carolina B.C.F.; Macedo, Thais R., E-mail: clorigados@usp.br [Universidade de Sao Paulo (FMVZ/USP), SP (Brazil). Fac. de Medicina Veterinaria e Zootecnia. Dept. de Cirurgia; Coppi, Antonio A.; Ladd, Fernando V.L. [Universidade de Sao Paulo (LSSCA/USP), SP (Brazil). Fac. de Medicina Veterinaria e Zootecnia. Lab. de Estereologia Estocastica e Anatomia Quimica; Souza, Vanessa A.F. de [Faculdades Metropolitanas Unidas (FMU), Sao Paulo, SP (Brazil). Curso de Medicina Veterinaria

    2013-11-15

    Nineteen dogs with mast cell tumors treated with chemotherapy were evaluated by computed tomography (CT). Were evaluated aspects related to contours, attenuation, postcontrast enhancement and presence of cleavage with adjacent structures. The RECIST criteria and volumetric measurement of lesions were performed to assess the response to treatment. The mast cell tumors presented a homogeneous or heterogeneous attenuation, presented more frequently a well delineated and regular contours and moderate enhancement after intravenous administration of the iodinated contrast media. The methods RECIST and volumetric measurements showed an excellent agreement to the classification of therapeutic response, providing a good parameter of the response to treatment. The CT examination proved to be useful in the delimitation of the tumor and an important tool for planning of surgical margins. (author)

  8. Interstitial pulmonary alterations in visceral leishmaniasis: evaluation with high-resolution computed tomography; Alteracoes pulmonares intersticiais na leishmaniose visceral: avaliacao pela tomografia computadorizada de alta resolucao

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Norma Selma Santos; Cerri, Giovanni Guido [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Dept. de Radiologia

    1999-08-01

    Visceral leishmaniasis, also called kala-azar, is a disease caused by a protozoan, the Leishmania donovani chagasi, that comprises reticuloendothelial system with involvement of the liver, spleen and bone marrow. It is endemic in some areas of northeastern Brazil and other countries of Latin America and Africa. The pathogenesis is related to the immunologic system of patients that present with the inability to activate the phagocytosis of the macrophages. As occurs in the liver and kidneys, the lungs are also involved with interstitial abnormalities caused by Leishmania that are not dependent upon the presence of the parasite. The histopathologic changes described are the involvement of inter alveolar septal in three different phases, irregularly and diffusely throughout the whole pulmonary parenchyma. This work analyzed high-resolution computed tomography (HRCT) of the thorax in 17 patients with visceral leishmaniasis in order to detect and characterize the abnormalities described in the anatomo pathologic findings reported in the literature. The HRCT is being used to evaluate chronic interstitial lung disease in a good correlation with histologic findings. The most common findings detected by HRCT were the reticular opacities that include peribronchovascular interstitial thickening and interlobular septal thickening an ground-glass opacity. The HRCT suggests that similar changes to that found in alveolar structures may occur in the secondary pulmonary lobule and that the involvement in the parenchymal interstitium represents the findings reported by pathological studies in visceral leishmaniasis. (author)

  9. Evaluation of the natural radioactivity at sands of anomalous regions of Espirito Santo state, Brazil; Avaliacao da radioatividade natural em areias de regioes anomalas do Espirito Santo, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Aquino, Reginaldo Ribeiro de; Pecequilo, Brigitte Roxana Soreanu, E-mail: raquino@ipen.b, E-mail: brigitte@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-10-26

    The natural radioactivity in sands of anomalous regions of the state of Espirito Santo, Brazil, were calculated from the concentration of activity of {sup 40}K, {sup 225}Ra and {sup 232}Th for the places of south and central of Camburi, Curva da Jurema, Ilha do Boi, Setibinha, south and central area of Praia da Areia Preta, denominated Black Spot. The samples were sealed and measured by high resolution gamma spectrometry and after a expectation time pf 30 days, until to reach a radioactive equilibrium

  10. Avaliação da reprodutibilidade da tomografia computadorizada no estadiamento da pancreatite aguda Reproducibility in the assessment of acute pancreatitis with computed tomography

    Directory of Open Access Journals (Sweden)

    Edison de Oliveira Freire Filho

    2007-12-01

    Full Text Available OBJETIVO: Medir a reprodutibilidade da tomografia computadorizada sem e com contraste na avaliação da gravidade da pancreatite aguda. MATERIAIS E MÉTODOS: Cinqüenta e um exames de tomografia computadorizada abdominal sem e com contraste de pacientes com pancreatite aguda foram analisados por dois radiologistas (observadores 1 e 2. Calculamos o índice morfológico pela tomografia computadorizada sem e com contraste, separadamente, e o índice de gravidade da tomografia computadorizada para pancreatite aguda. Medimos a reprodutibilidade intra- e interobservador da tomografia computadorizada através do índice kappa (kapa. RESULTADOS: Para a concordância interobservador obtivemos kapa de 0,666, 0,705, 0,648, 0,547 e 0,631 para índice morfológico sem e com contraste, presença de necrose pancreática, extensão da necrose pancreática e índice de gravidade da tomografia computadorizada, respectivamente. Para a concordância intra-observador dos observadores 1 e 2 obtivemos, respectivamente, kapa de 0,796 e 0,732 para o índice morfológico sem contraste; 0,725 e 0,802 para o índice morfológico com contraste; 0,674 e 0,849 para a presença de necrose pancreática; 0,606 e 0,770 para a extensão da necrose pancreática; e 0,801 e 0,687 para o índice de gravidade da tomografia computadorizada. CONCLUSÃO: O estadiamento da pancreatite aguda pela tomografia computadorizada por meio do índice morfológico e do índice de gravidade da tomografia computadorizada é um método bastante reprodutível. O não-uso do contraste não afeta a reprodutibilidade da tomografia computadorizada para o cálculo do índice morfológico.OBJECTIVE: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. MATERIALS AND METHODS: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two

  11. Evaluation of the repeatability of dosimetric parameters of a linear accelerator beam; Avaliacao da repetibilidade de parametros dosimetricos do feixe de um acelerador linear

    Energy Technology Data Exchange (ETDEWEB)

    Morelli, Humberto A.S.; Oliveira, Harley F. de; Silva, Maelson do N.; Pavoni, Juliana F., E-mail: h.morelli@hotmail.com [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Servico de Radioterapia

    2016-07-01

    This study aims to evaluate the repeatability of symmetry and flatness of the photon beam of 6 MV linear accelerator Oncor Impression, Siemens, from the Radiotherapy Department of the Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto - USP. In total they were collected 102 measures, weekly, through two-dimensional detector of ionization chambers, Matrixx Evolution, IBA Dosimetry, connected to a computer with software OmniProI'mrt. The isocenter of the linear accelerator was placed in the center of the sensitive volume of the detector with solid water plates above and below these. Data were collected with 100 UM, with field size 10 x 10 cm². The flatness and symmetry values were calculated by the software used. The first measurement of this work was used as reference, the others were compared with it, taking into account the values of permissible variation for these parameters. The minimum, maximum and average value were analyzed. The literature indicates that the flatness and symmetry values should not vary by more than 2 and 3%, respectively. The results of this work show that the values of these parameters for the linear accelerator study are within the permissible variations in protocols and are therefore able to appropriate clinical use. (author)

  12. Critical evaluation of the external occupational exposure in nuclear medicine services in Brazil; Avaliacao critica da exposicao ocupacional externa nos servicos de medicina nuclear no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Ana Luiza Silva Lima

    2016-07-01

    and middle fingers of the non-dominant hand for professionals who carry out preparation of the radiopharmaceutical and the index finger of the dominant hand for those who perform injection in conventional NMS and making fractionation and injection in the case of Positron Emission Tomography (PET). Thus, measurements with dosimetric rings estimate better the extremity equivalent dose than bracelets, which can underestimate the hand equivalent dose by a factor between 10 and 20. Unlike the effective dose, the possibility that an occupational equivalent dose value exceeds the annual limit is real. The ability of the operator and the use of shielding seem to be more important to the magnitude of the dose than the used fractionation technique, which is highly relevant for the dose distribution in the hands. (author)

  13. Evaluation of home-made teas efficiency from medicinal plants used on childish diarrhea treatment; Avaliacao da eficacia de chas caseiros de plantas medicinais utilizados no tratamento da diarreia infantil

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Magda Moreira; Silva, Maria Jose de Sousa Ferreira da [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Dept. de Quimica; Vilhena Schayer Sabino, Claudia de; Amaral, Angela Maria [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil)

    1996-03-01

    The objective of this work is to verify whether the home-made teas form Brazilian plants, used for control of childish diarrhea have been efficient reaching the composition recommended by World Health Organizations (WHO). This work has been carried out using the neutron activation analysis and the TRIGA MARK I reactor, the IPR-R1, in the Centro de Desenvolvimento da Tecnologia Nuclear - CDTN. (author). 4 refs., 2 tabs.

  14. Tomography

    International Nuclear Information System (INIS)

    1985-01-01

    Already widely accepted in medicine, tomography can also be useful in industry. The theory behind tomography and a demonstration of the technique to inspect a motorcycle carburetor is presented. To demonstrate the potential of computer assisted tomography (CAT) to accurately locate defects in three dimensions, a sectioned 5 cm gate valve with a shrink cavity made visible by the sectioning was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +-1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  15. System precision assessment ExacTrac 6D® BrainLab of the Hospital das Clinicas da Faculdade de Medicina da USP; Avaliacao da precisao do sistema Exactrac 6D® BrainLab do Hospital das Clinicas da Faculdade de Medicina da USP

    Energy Technology Data Exchange (ETDEWEB)

    Maistro, Carlos E.B., E-mail: carloseduardo.bravinmaistro@gmail.com [Programa de Residencia Multiprofissional em Fisica Medica, Faculdade de Medicina de Sao Paulo, SP (Brazil); Nakandakari, Marcos V.N.; Ribeiro, Victor A.B.; Sales, Camila P. de; Rodrigues, Laura N. [Universidade de Sao Paulo (USP), SP (Brazil). Instituto de Radiologia. Servico de Radioterapia. Hospital das Clinicas

    2015-08-15

    The goal of this study was to evaluate the precision of ExacTrac 6D® Brainlab system, installed at Hospital das Clinicas da Faculdade de Medicina da USP, in frameless radiosurgery treatments. Four sets of tests were performed for different purposes in order to assess the following parameters: the accuracy of location through infrared system; evaluation of the reproducibility of fusion algorithm; evaluation of the X-ray system; and the end-to-end test with the goal of assess the overall accuracy of the system. It was found that the infrared system showed a maximum deviation of 0.5 mm in terms of positioning and the X-ray system showed a precision of 0.15 mm and 0.6°. The reproducibility of fusion algorithms provided a maximum deviation in position which was less than 0.5 mm and 0.5° and the quantitative analysis of the results for end-to-end test showed an overall accuracy of the system better than 0.8 mm. (author)

  16. Tomography

    International Nuclear Information System (INIS)

    Barrett, H.H.; Gordon, S.; Swindell, W.

    1980-01-01

    Apparatus is described for generating a two-dimensional back-projected image of a slice of an object in tomography. The apparatus uses optical techniques to perform the functions of filtering and back projection. Central to the technique is a cylindrical drum which rotates at a fast rate and whose rotational axis tilts at a slower rate. The novel method overcomes the problem of image blurring due to motion which occurs in many tomographic techniques. It also has the advantages of being less expensive and simpler compared to tomography using digital processing techniques which require fast computers. (UK)

  17. Radiolabelled molecules for imaging the translocator protein (18 kDa) using positron emission tomography

    International Nuclear Information System (INIS)

    Dolle, F.; Luus, C.; Reynolds, A.; Kassiou, M.

    2009-01-01

    The translocator protein (18 kDa) (TSPO), formerly known as the peripheral benzodiazepine receptor (PBR), was originally identified as an alternate binding site for the central benzodiazepine receptor (CBR) ligand, diazepam, in the periphery, but has now been distinguished as a novel site. The TSPO is ubiquitously expressed in peripheral tissues but only minimally in the healthy brain and increased levels of TSPO expression have been noted in neuro inflammatory conditions such as Alzheimer's disease, Parkinson's disease and stroke. This increase in TSPO expression has been reported to coincide with the process of micro-glial activation, whereby the brain's intrinsic immune system becomes active. Therefore, by using recently developed high affinity, selective TSPO ligands in conjunction with functional imaging modalities such as positron emission tomography (PET), it becomes possible to study the process of micro-glial activation in the living brain. A number of high affinity ligands, the majority of which are C, N-substituted acetamide derivatives, have been successfully radiolabelled and used in in vivo studies of the TSPO and the process of micro-glial activation. This review highlights recent achievements (up to December 2008) in the field of functional imaging of the TSPO as well as the radio-syntheses involved in such studies. (authors)

  18. Evaluation of multiple scan average dose (MSAD) levels in computerized tomography in Minas Gerais state, Brazil; Avaliacao dos niveis de dose media em cortes multiplos (MSAD) em tomografia computadorizada no estado de Minas Gerais

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Thessa C., E-mail: alonso@cdtn.br [Centro de Desenvolvimento de Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Vieira, Leandro de A.; Barbosa, Nayra V.; Oliveira, Jeyselaine R. de; Cesar, Adriana C.Z. [Secretaria de Vigilancia Sanitaria de Minas Gerais, Belo Horizonte, MG (Brazil); Silva, Teogenes A. da [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear. Programa de Ciencias e Tecnicas Nucleares

    2014-07-01

    Computed Tomography (CT) grows every year and is a diagnostic method that has revolutionized radiology with advances in procedures for obtaining image. However, the indiscriminate use of this method generates relatively high doses in patients. The diagnostic reference levels (DRLs) is a practical tool to promote the evaluation of existing protocols. The optimization and the periodic review of the protocols are important to balance the risk of radiation. The present study aims to conduct a survey of levels of MSAD of Minas Gerais following the procedures recommended by current Brazilian law. (author)

  19. Tomography

    International Nuclear Information System (INIS)

    Allan, C.J.; Keller, N.A.; Lupton, L.R.; Taylor, T.; Tonner, P.D.

    1984-10-01

    Tomography is a non-intrusive imaging technique being developed at CRNL as an industrial tool for generating quantitative cross-sectional density maps of objects. Of most interest is tomography's ability to: distinguish features within complex geometries where other NDT techniques fail because of the complexity of the geometry; detect/locate small density changes/defects within objects, e.g. void fraction measurements within thick-walled vessels, shrink cavities in castings, etc.; provide quantitative data that can be used in analyses, e.g. of complex processes, or fracture mechanics; and provide objective quantitative data that can be used for (computer-based) quality assurance decisions, thereby reducing and in some cases eliminating the present subjectivity often encountered in NDT. The CRNL program is reviewed and examples are presented to illustrate the potential and the limitations of the technology

  20. Computed tomography prospective study of pleural-pulmonary changes after abdominal surgery : assessment of associated risk factors; Estudo prospectivo por tomografia computadorizada das alteracoes pleuro-pulmonares apos cirurgia abdominal: avaliacao dos fatores de risco associados

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Luis Antonio [Pontificia Univ. Catolica de Sao Paulo, SP (Brazil). Centro de Ciencias Medicas e Biologicas]. E-mail: luizrossimd@uol.com.br; Bromberg, Sansom Henrique [Instituto de Assistencia Medica ao Servidor Publico Estadual de Sao Paulo (IAMSPE), Sao Paulo, SP (Brazil). Curso de Pos-graduacao em Gastroenterologia Cirurgica

    2005-07-01

    Postoperative pleural-pulmonary changes (PPC) are very common following elective abdominal surgery, resolving without clinical manifestations in most patients. The incidence and risk factors associated are unknown. Objective: to determine the incidence of PPC and possible association with risk factors using computerized tomography (CT). Material and method: thirty seven patients submitted to elective abdominal surgery were prospectively analyzed using CT performed in the preoperative period and 48 hours after surgery. The PPC was scored from 0 to III. The risk factors evaluated were: age, sex, obesity, smoking history, alcoholism, comorbid conditions, cancer, ASA classification, duration of surgery, surgical incision type and number of days of hospitalization. Results: Pleura effusion was detected by CT in 70.3% (26/37) of the patients and pulmonary atelectasis in 75.5% (28/37). Grade I and II PPC was found in 59.5% (22/37) of the patients and grade III in 21.6% (8/37). Two (5.4%) of these patients developed serious pulmonary complications whereas one patient died. Surgery due to cancer, class ASA >2, longitudinal incision and > 15 cm showed statistical significance and were associated with pleural effusion. The hospitalization was over 2.4 longer for patients with PPC. Conclusion: PPC is frequently seen in patients submitted to abdominal surgery. The use of the CT for the detection of pulmonary atelectasis and pleural effusion proved to be effective. Most cases of PPC are self-limited, resolving without symptoms. (author)

  1. Evaluation of standard and use tendency of image diagnosis exams in Brazil with emphasis in pediatric computerized tomography; Avaliacao do padrao e tendencia de uso de exames de diagnostico por imagem no Brasil com enfase em tomografia computadorizada pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Dovales, Ana Cristina Murta

    2016-07-01

    There is little information on developing countries about the use of diagnostic imaging procedures and the doses associated with radiological examinations. This study assessed the pattern and trend of diagnostic imaging usage in outpatients of the Brazilian Unified Health System (SUS) by modality and examined body part. Emphasis was given to computed tomography (CT) scans for which the analysis was extended to the private health care sector and included the evaluation of age at examination distribution, and dose estimation for children and young adults. Information on the use of diagnostic imaging procedures among SUS outpatients was obtained from the Outpatient Information System (SIA) of the Department of Information Technology of SUS (DATASUS). Data on the use of CT in the private health care sector were extracted from the Radiological Information Systems (RIS) of 25 private radiology services in 8 Brazilian cities. Effective doses and absorbed doses on organs of interest were estimated individually for 4,497 patients younger than 20 years of age using CT scan technical parameters and Monte Carlo simulations of radiation transport. Between 2002 and 2012 it was observed that conventional radiology was the most frequent modality of diagnostic imaging in SUS outpatients, but more sophisticated modalities, such as CT and magnetic resonance imaging, had the highest growth rates over the study period. The most frequent CT scan in SUS outpatients between 2001 and 2011 was the head/neck exam, but abdomen/pelvis examinations were the ones that grew the most. Patients up to 20 years of age made approximately 13% and 9% of the CT examinations between 2008 and 2014 in the public and private health care systems, respectively. About one-third of the private-sector patients had more than one CT scan in this period. There was great variation in doses, even for the same type of procedure in patients of the same age group. The highest mean effective dose was 13.5 mSv estimated

  2. Hunting for the Tristan mantle plume - An upper mantle tomography around the volcanic island of Tristan da Cunha

    Science.gov (United States)

    Schlömer, Antje; Geissler, Wolfram H.; Jokat, Wilfried; Jegen, Marion

    2017-03-01

    The active volcanic island Tristan da Cunha, located at the southwestern and youngest end of the Walvis Ridge - Tristan/Gough hotspot track, is believed to be the surface expression of a huge thermal mantle anomaly. While several criteria for the diagnosis of a classical hotspot track are met, the Tristan region also shows some peculiarities. Consequently, it is vigorously debated if the active volcanism in this region is the expression of a deep mantle plume, or if it is caused by shallow plate tectonics and the interaction with the nearby Mid-Atlantic Ridge. Because of a lack of geophysical data in the study area, no model or assumption has been completely confirmed. We present the first amphibian P-wave finite-frequency travel time tomography of the Tristan da Cunha region, based on cross-correlated travel time residuals of teleseismic earthquakes recorded by 24 ocean-bottom seismometers. The data can be used to image a low velocity structure southwest of the island. The feature is cylindrical with a radius of ∼100 km down to a depth of 250 km. We relate this structure to the origin of Tristan da Cunha and name it the Tristan conduit. Below 250 km the low velocity structure ramifies into narrow veins, each with a radius of ∼50 km. Furthermore, we imaged a linkage between young seamounts southeast of Tristan da Cunha and the Tristan conduit.

  3. Tomography

    International Nuclear Information System (INIS)

    Brown, B.H.; Barber, D.C.; Freeston, I.L.

    1983-01-01

    Tomography images of a body are constructed by placing a plurality of surface electrodes at spaced intervals on the body, causing currents to flow in the body (e.g. by applying a potential between each pair of electrodes in turn, or by induction), and measuring the potential between pairs of electrodes, calculating the potential expected in each case on the assumption that the body consists of a medium of uniform impedance, plotting the isopotentials corresponding to the calculated results to create a uniform image of the body, obtaining the ratio between the measured potential and the calculated potential in each case, and modifying the image in accordance with the respective ratios by increasing the assumed impedance along an isopotential in proportion to a ratio greater than unity or decreasing the assumed impedance in proportion to a ratio less than unity. The modified impedances along the isopotentials for each pair of electrodes are superimposed. The calculations are carried out using a computer and the plotting is carried out by a visual display unit and/or a print-out unit. (author)

  4. Analysis of the computed tomography in the acute abdomen; Analise da tomografia computadorizada no abdome agudo

    Energy Technology Data Exchange (ETDEWEB)

    Hochhegger, Bruno [Complexo Hospitalar Santa Casa de Porto Alegre, RS (Brazil); Moraes, Everton [Universidade Federal de Santa Maria (UFSM), RS (Brazil); Haygert, Carlos Jesus Pereira; Antunes, Paulo Sergio Pase [Hospital Universitario de Santa Maria, RS (Brazil); Gazzoni, Fernando [Pontificia Universidade Catolica de Porto Alegre (PUC-RS), Porto Alegre, RS (Brazil). Hospital Sao Lucas; Andrade, Rubens Gabriel Feijo [Fundacao Universitaria de Cardiologia de Porto Alegre, RS (Brazil). Inst. de Cardiologia; Bueno, Leticia Rossi [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil); Lopes, Luis Felipe Dias [Universidade Federal de Santa Maria (UFSM), RS (Brazil). Dept. de Estatistica]. E-mail: brunorgs@pop.com.br

    2007-07-01

    Introduction: This study tends to test the capacity of the computed tomography in assist in the diagnosis and the approach of the acute abdomen. Material and method: This is a longitudinal and prospective study, in which were analyzed the patients with the diagnosis of acute abdomen. There were obtained 105 cases of acute abdomen and after the application of the exclusions criteria were included 28 patients in the study. Results: Computed tomography changed the diagnostic hypothesis of the physicians in 50% of the cases (p < 0.05), and the confidence index in 85.71% of the cases (p 0.014). Computed tomography also altered the management in 46.43% of the cases (p > 0.05), where 78.57% of the patients had surgical indication before computed tomography and 67.86% after computed tomography (p = 0.0546). The index of accurate diagnosis of computed tomography, when compared to the anatomopathologic examination and the final diagnosis, was observed in 82.14% of the cases (p = 0.013). When the analysis was done dividing the patients in surgical and nonsurgical group, were obtained an accuracy of 89.28% (p 0.0001). The difference of 7.2 days of hospitalization (p = 0.003) was obtained compared with the mean of the acute abdomen without use the computed tomography. Conclusion: The computed tomography is correlative with the anatomopathology and has great accuracy in the surgical indication, associated with the capacity of increase the confident index of the physicians, reduces the hospitalization time, reduces the number of surgeries and is cost-effective. (author)

  5. Are the imaging findings used to assess the portal triad reliable to perform living-donor liver transplant?; Os achados de imagem para avaliacao da triade portal sao confiaveis para realizacao do transplante hepatico com doador vivo?

    Energy Technology Data Exchange (ETDEWEB)

    Dazzi, Francisco Leoncio; Ribeiro Junior, Marcelo Augusto Fontenelle; Mancero, Jorge Marcelo Padilla; Gonzalez, Adriano Miziara; D' Albuquerque, Luiz Augusto Carneiro, E-mail: franciscodazzi@hotmail.com [Hospital Beneficencia Portuguesa, Sao Paulo, SP (Brazil). Departamento de Cirurgia Geral e Transplante; Leao-Filho, Hilton Muniz [Hospital Beneficencia Portuguesa, Sao Paulo, SP (Brazil). Departamento de Radiologia e Diagnostico por Imagem; Silva, Adavio de Oliveira e [Hospital Beneficencia Portuguesa, Sao Paulo, SP (Brazil). Departamento de Gastroenterologia e Hepatologia

    2013-07-01

    Background: a crucial aspect of living-donor liver transplant is the risk imposed to the donor due to a procedure performed in a healthy individual that can lead to a high postoperative morbidity rate Aim: To correlate the pre- and intraoperative hepatic imaging findings of living adult donors. Methods: From 2003 to 2008 the medical charts of 66 donors were revised; in that, 42 were males (64%) and 24 females (36%), mean age of 30±8 years. The preoperative anatomy was analyzed by magnetic resonance cholangiography to study the bile ducts and by computed tomography angiography to evaluate the hepatic artery and portal vein. Normalcy criteria were established according to previously published studies. Results: Anatomic variations of the bile ducts were found in 59.1% of donors, of the artery hepatic in 31.8% and of the portal vein in 30.3% of the cases during the preoperative period. The magnetic resonance cholangiography findings were in agreement in 44 (66.6%) of donors and in disagreement in 22 (33.3%). With regards to hepatic artery, in all donors the findings of the imaging examination were in agreement with those of the intraoperative period. As to the portal vein, the computed tomography findings were in agreement in 59 (89.4%) donors and in disagreement in seven (10.6%). Conclusions: the bile duct anatomic variations are frequent, and the magnetic resonance cholangiography showed moderate accuracy (70%) in reproducing the surgical findings; the computed tomography reproduced the intraoperative findings of the hepatic artery in 100% of donors, and of the portal vein in 89.4% of the cases, thus demonstrating high accuracy (89%). (author)

  6. Thermal hydraulic evaluation for an experimental facility to investigate pressurized thermal shock (PTS) in CDTN/CNEN; Avaliacao termo-hidraulica da montagem experimental de choque termico pressurizado do CDTN/CNEN

    Energy Technology Data Exchange (ETDEWEB)

    Palmieri, Elcio T.; Navarro, Moyses A.; Aronne, Ivam D.; Terra, Jose L. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil)

    2002-07-01

    The goal of the work presented in this paper is to provide necessary thermal hydraulics information to the design of an experimental installation to investigate the Pressurized Thermal Shock (PTS) to be implemented at Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN). The envisaged installation has a test section that represents, in a small scale, a pressure vessel of a nuclear reactor. This test section will be heated and then exposed to a PTS in order to evaluate the appearance and development of cracks. To verify the behavior of the temperatures of the pressure vessel after a sudden flood through the annulus, calculations were made using the RELAP5/MOD 3.2.2 gamma code. Different outer radiuses were studied for the annular region. The results showed that the smaller annulus spacing (20 mm) anticipates the wetting of the surface and produces a higher cooling of the external surface, which stays completely wet for a longer time. (author)

  7. Evaluation of solubility in simulated lung fluid of metals present in the sludge from a metallurgical industry to produce metallic zinc; Avaliacao da solubilidade em liquido pulmonar simulado dos metais presentes no rejeito gerado por uma industria metalurgica de zinco

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Rosilda Maria Gomes de

    2012-07-01

    The objective of this study was to determine the solubility parameters (rapid and slow dissolution rates, rapid and slow dissolution fractions) metal particles present in a pile of sludge accumulated under exposure to weathering from the Cia Mercantil Inga, located at the Ilha da Madeira, Sepetiba Bay, Rio de Janeiro. Plant samples collected in the neighboring of the pile and bioindicators placed in the region and collected after some months indicated that the inhabitants of Ilha da Madeira have been exposed to trace elements such zinc, cadmium, mercury and lead, produced during the processing of zinc minerals (hemimorphite - Zn{sub 4}(OH){sub 2}Si{sub 2}O{sub 7}.H{sub 2}O, and willemite - Zn{sub 2}SiO{sub 4}). A static dissolution test in vitro was used to determine the solubility parameters using a simulated lung fluid (SLF), on a time basis ranging from 10 min to 1 year. The metal concentrations in the sludge samples and in the SLF were determined using Particle Induced X-rays Emission (PIXE). In conclusion, this study confirms the harmful effects on the neighboring population of the airborne particles containing these metals that came from the sludge. The solubility parameters obtained for Zn, Cd, Cr, Ni and Mn present in the rapid dissolution fraction in SLF were 0.945; 0.473; 0.226; 0.300 and 0.497, respectively, and the corresponding times for half life of dissolution of the rapid fraction were f{sub r} = 2.082 days; f{sub r} = 0.09 days; f{sub r} = 0.37 days; f{sub r} = 0.332 days ad f{sub r} = 0.99 days; for the slow dissolution fraction times were f{sub r} = 146.95 days; f{sub r} = 63 days; f{sub r} = 86.64 days; f{sub r} = 79.66 days and f{sub r} = 59.84 days. These values indicate that these metals present a moderate absorption level in SLF, and may be classified as M type, according to the International Commission on Radiological Protection (ICRP). The use of solubility parameters allowed a better description of the kinetic behaviour of the sludge in

  8. Computerized tomography findings in Fahr's syndrome Achados da tomografia computadorizada na síndrome de Fahr

    Directory of Open Access Journals (Sweden)

    Andréia V. Faria

    2004-09-01

    Full Text Available We analyzed computerized tomography (CT findings in six patients with Fahr's syndrome. They presented calcifications in basal ganglia, dentate nucleus, subcortical region and semioval center, due to alteration in calcium metabolism or due to senile relative hypoxemic state. The image pattern was not strictly related with etiology, although some differences in dystrophic senile calcifications (the only one present in semioval center and absent in subcortical region. CT is an easy exam, has maximum sensitivity and allows diagnosis, contributing to early treatment of many etiologies of Fahr's syndrome.Analisamos os achados de tomografia computadorizada (TC de seis pacientes com síndrome de Fahr. Eles apresentaram calcificações nos gânglios da base, núcleo denteado, região subcortical e centro semi-oval, devidas a distúrbios no metabolismo do cálcio ou a estado de hipóxia relativa, por senilidade. O padrão de imagem não apresenta relação clara com a etiologia, apesar de algumas diferenças no caso das calcificações distróficas senis (as únicas presentes nos centros semi-ovais e ausentes na região subcortical. TC é um exame de fácil realização, máxima sensibilidade e permite o diagnóstico, contribuindo para o tratamento precoce de muitas das etiologias da síndrome de Fahr.

  9. Development of methodologies for internal exposure assessment due to the radiopharmaceutical {sup 18}FDG; Desenvolvimento de metodologias para avaliacao da exposicao ocupational interna devido ao radiofarmaco {sup 18}FDG

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, Isabelle Viviane Batista de

    2013-07-01

    The production of {sup 18}F has increased in the last decade. It is produced basically for the synthesis of {sup 18}F- fluorodeoxyglucose ({sup 18}FDG), the main radiopharmaceutical used in PET (Positron Emission Tomography) scans. The growth in the frequency of these tests resulted in rise of the number of occupationally exposed individuals (OEI) to the radionuclide {sup 18}F as {sup 18}FDG, increasing thereby the probability of its accidental incorporation. This study aimed to implement optimized techniques for assessing internal exposures of individuals occupationally exposed through both in vivo and in vitro bioassay methods during production and handling of {sup 18}FDG at the Divisao de Producao de Radiofarmacos (DIPRA), Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN). The in vivo monitoring was conducted at the Laboratorio de Dosimetria Interna, Divisao de Laboratorios Tecnico-Cientificos (DILAB). For this bioassay method, measurements were done with a 3x3' NaI(Tl) scintillation detector coupled to Genie 2000 software. The calibration of the system was performed with a brain phantom containing a standard liquid source of {sup 22}Na to simulate a contaminated individual. The calibration of the HPGe coaxial detector for in vitro monitoring was performed at the Laboratorio de Medidas de Atividade de Radionuclideos (DIPRA/CRCN-NE/CNEN) with a standard source of {sup 22}Na. Base on the calibration factors, it was possible to determine the minimum detectable activities (MDA) for the systems by using direct measurements and simulation of uncontaminated urine. Then, through the biokinetic models published by ICRP 106 and edited by the AIDE software (version 6.0), it was possible to estimate the minimum detectable effective dose (MDED), which evaluates the detection sensitivity of the techniques developed. The MDED was estimated for in vivo and in vitro measurements performed 2.4 hours after the occurrence of incorporation by ingestion, since

  10. Tomografia computadorizada no diagnóstico da otosclerose retrofenestral Computed tomography in the diagnosis of retrofenestral otosclerosis

    Directory of Open Access Journals (Sweden)

    Andy de Oliveira Vicente

    2004-01-01

    Full Text Available OBJETIVO: Identificar os principais achados tomográficos da otosclerose retrofenestral. MÉTODO: Estudo prospectivo multicêntrico com tomografia computadorizada (TC de ossos temporais em 54 pacientes com diagnóstico clínico e cirúrgico de otosclerose. Foi realizada uma análise tomográfica, em que foi avaliada a utilidade da TC no diagnóstico radiológico da otosclerose retrofenestral, sendo verificados os principais sítios de lesões dessa doença. Foram incluídos neste estudo 22 pacientes submetidos à TC de ossos temporais para investigação de outras afecções otológicas, que constituíram o grupo controle. RESULTADOS: Os achados tomográficos foram bilaterais na maioria dos casos e o foco retrofenestral mais prevalente foi o foco pericoclear. CONCLUSÕES: A TC monstrou-se útil na identificação dos focos retrofenestrais. A evidência tomográfica desses focos juntamente com o envolvimento endosteal da cóclea podem sugerir uma maior atividade da doença.AIM: To identify the main tomographic findings of retrofenestral otosclerosis. METHODS: A prospective and multicentric study using computed tomography (CT of the temporal bone in 54 patients with a clinical and surgical diagnosis of otosclerosis. A tomographic analysis has been performed to evaluate the utility of CT scans in diagnosing retrofenestral otosclerosis, verifying the sites of predilection for otosclerotic lesions. In this study, 22 patients undergone CT scans of temporal bones have been included in order to investigate other otologic diseases and have constituted the control group. RESULTS: The tomographic findings were mostly bilateral and the retrofenestral focus more prevalent was the pericochlear focus. CONCLUSIONS: The CT scan was useful in the identification of the retrofenestral focuses. The evidence of this focuses and the presence of the endosteal involvement of the cochlea can suggest a higher activity of the disease.

  11. Study of crotoxin mechanism of action to mammary carcinomas and evaluation of its potential as a radiopharmaceutical; Estudo do mecanismo de acao da crotoxina em tumores mamarios e avaliacao do seu potenctial radiofarmaceutico

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Marina Bicalho

    2010-07-01

    Crotoxin, the main component of Crotalus durissus terrificus snake venom, has been studied since 1938. It is a natural polypeptidic complex with pharmacological potential because of its antitumoral properties which has attracted great interest for diagnosis and therapy of oncological diseases. However, Crotoxin mechanism of action and sites of specific interaction on tumor cells are still misunderstood. Breast cancer is the second most frequent type in the world and the most common cancer in women. About 30 to 60% of mammary tumors overexpress epidermal growth factor receptor (EGFR), a transmembrane protein related to cell proliferation. Since literature has reported that Crotoxin antitumoral effect is more potent on cells with EGFR overexpression the objectives of this work were to evaluate Crotoxin cytotoxic effects on mammary tumor cells human breast carcinoma (MCF-7) and Ehrlich tumor cells (murine ascitics carcinoma), and to investigate the specific molecular interaction of Crotoxin on Ehrlich tumor cells. Initially, Crotoxin was radiolabelled with iodine-125 ({sup 125}I-Crotoxin) and iodine-131 ({sup 131}I-Crotoxin). Saturation and competition assay were carried out to characterize Crotoxin in vitro interaction; Crotoxin biodistribution studies and singlephoton emission computed tomography (SPECT) of mice bearing Ehrlich tumor have been evaluated to describe in vivo interaction. Our results showed that Crotoxin presented cytotoxic effect against Ehrlich with DL{sub 50} in vitro (concentration of compound which is lethal for 50% of cells) of about one micromolar, but did not present significant effect against MCF-7. Morphological alterations characteristic of apoptosis suggests programmed cell death. {sup 125}I-Crotoxin interaction with Ehrlich tumor cells was saturable with approximately 70% specificity, and presented K{sub d}=24.98 nmol/L and B{sub max}=16,570 sites/cell for low affinity binding sites and K{sub d}=0.06 nmol/L and B{sub max}=210 sites

  12. Stratus optical coherence tomography findings in patients with retinopathy of prematurity Tomografia de coerência óptica em pacientes com retinopatia da prematuridade

    Directory of Open Access Journals (Sweden)

    Aline do Lago

    2007-02-01

    Full Text Available PURPOSE: To describe morphological features of the macula in patients with retinopathy of prematurity. METHODS: Twelve premature babies with retinopathy of prematurity grades I, II and III underwent dilated fundus examination and optical coherence tomography evaluation. RESULTS: In all thirteen eyes of the twelve premature patients optical coherence tomography revealed a condensed retinal pigmented epithelial layer in the macular-foveal area shown by increased reflectivity. In these eyes the retinal layers were not well differentiated. Foveal depression was clearly evident in 23%. CONCLUSIONS: In premature patients with retinopathy of prematurity, optical coherence tomography revealed poorly differentiated layers in the macular region with increased reflectivity in retinal pigmented epithelial-choriocapillaris zone.OBJETIVO: Descrever os aspectos morfológicos da mácula em pacientes com retinopatia da prematuridade (ROP. MÉTODOS: Doze pacientes com retinopatia da prematuridade graus I, II and III foram submetidos a mapeamento de retina e avaliação por tomografia de coerência óptica. RESULTADOS: Em todos os treze olhos de 12 pacientes a tomografia de coerência óptica mostrou a camada do epitélio pigmentar hiperrefletiva, sendo a área macular com maior intensidade. Nesses olhos as camadas da retina não estavam totalmente diferenciadas. A depressão foveal ficou claramente evidente pela tomografia de coerência óptica em 23%. CONCLUSÃO: Nos pacientes prematuros com retinopatia da prematuridade, a tomografia de coerência óptica mostrou as camadas da retina pouco diferenciadas com aumento da refletividade na área macular do complexo epitélio retiniano pigmentar-coriocapilar.

  13. Avaliação da expansão rápida da maxila por meio da tomografia computadorizada: relato de um caso Computed tomography evaluation of rapid maxillary expansion: a case report

    Directory of Open Access Journals (Sweden)

    Daniela Gamba Garib

    2005-08-01

    Full Text Available Este trabalho descreve os efeitos dentoesqueléticos e periodontais da expansão rápida da maxila (ERM, avaliados por meio da tomografia computadorizada (TC, em uma jovem de 11,6 anos de idade com má oclusão de Classe I e mordida cruzada posterior unilateral funcional. Durante a fase ativa da ERM, o expansor dentossuportado com parafuso Hyrax foi ativado 7mm. A paciente submeteu-se ao exame de TC helicoidal, antes da expansão e após a remoção do aparelho expansor, findo o período de três meses de contenção. Realizaram-se cortes axiais, de um milímetro de espessura, paralelamente ao plano palatino, englobando as regiões dentoalveolar e basal da maxila, até o terço inferior da cavidade nasal. Utilizando-se o recurso de reconstruções multiplanares, mensuraram-se pelo método computadorizado: as dimensões transversas maxilares, a inclinação dos dentes posteriores, a espessura das tábuas ósseas vestibular e lingual, e o nível da crista óssea alveolar vestibular. A expansão rápida da maaxila ocasionou um significante aumento transverso em todas as regiões aferidas, com magnitude decrescente do arco dentário para a base óssea. Os dentes posteriores foram movimentados para vestibular, com um componente de inclinação e translação associados. Tal efeito ortodôntico ocasionou uma redução na espessura da tábua óssea vestibular, e um concomitante aumento na espessura da tábua óssea lingual. Após a expansão, observou-se o desenvolvimento de deiscências ósseas por vestibular dos dentes de ancoragem.This paper presents a computed tomography (CT evaluation of rapid maxillary expansion dentoskeletal and periodontal effects, in a 11.6 year-old girl presenting Class I malocclusion with posterior unilateral crossbite. The tooth-borne expander with Hyrax screw was activated 7-mm. The patient was submitted to helicoidal CT scan before expansion and after the three-month retention period when the expander was removed. Axial

  14. Translocator Protein-18 kDa (TSPO Positron Emission Tomography (PET Imaging and Its Clinical Impact in Neurodegenerative Diseases

    Directory of Open Access Journals (Sweden)

    Anne-Claire Dupont

    2017-04-01

    Full Text Available In vivo exploration of activated microglia in neurodegenerative diseases is achievable by Positron Emission Tomography (PET imaging, using dedicated radiopharmaceuticals targeting the translocator protein-18 kDa (TSPO. In this review, we emphasized the major advances made over the last 20 years, thanks to TSPO PET imaging, to define the pathophysiological implication of microglia activation and neuroinflammation in neurodegenerative diseases, including Parkinson’s disease, Huntington’s disease, dementia, amyotrophic lateral sclerosis, multiple sclerosis, and also in psychiatric disorders. The extent and upregulation of TSPO as a molecular biomarker of activated microglia in the human brain is now widely documented in these pathologies, but its significance, and especially its protective or deleterious action regarding the disease’s stage, remains under debate. Thus, we exposed new and plausible suggestions to enhance the contribution of TSPO PET imaging for biomedical research by exploring microglia’s role and interactions with other cells in brain parenchyma. Multiplex approaches, associating TSPO PET radiopharmaceuticals with other biomarkers (PET imaging of cellular metabolism, neurotransmission or abnormal protein aggregates, but also other imaging modalities, and peripheral cytokine levels measurement and/or metabolomics analysis was considered. Finally, the actual clinical impact of TSPO PET imaging as a routine biomarker of neuroinflammation was put into perspective regarding the current development of diagnostic and therapeutic strategies for neurodegenerative diseases.

  15. An assessment of ninth round; Nona: uma avaliacao da rodada

    Energy Technology Data Exchange (ETDEWEB)

    Assumpcao, Eduardo; Andrade, Leila; Fontana, Raphaela [Agencia Nacional do Petroleo, Gas Natural e Biocombustiveis (ANP), Rio de Janeiro, RJ (Brazil)

    2008-07-01

    Accomplished on November, 27{sup th}, 2007, 271 exploratory blocks were offered in Round 9, distributed within 14 sectors, totalling an area of 73 thousand km{sup 2}. The following basins were included: Campos, Espirito Santo, Para- Maranhao, Parnaiba, Pernambuco-Paraiba, Potiguar, Santos, Reconcavo and Rio do Peixe. From the original lot of 67 companies qualified (31 Brazilian and 36 of foreign origin), 42 offered bids individually or in partnerships. 117 blocks were allocated to 24 winning operator companies. Other 12 enterprises won acreage as non-operator participants of joint bids. A record of R$ 2,1 billion were offered as signature bonuses along with 169.436 units of the so called minimum exploratory programs. These units may be converted to an estimated R$ 1,4 billion. The objective of this paper is to evaluate the results obtained in Round 9, analyzing collected data through three different perspectives of aggregate results: bidding companies, offered areas and exploratory models. (author)

  16. Sacroiliitis: imaging evaluation; Sacroiliite: avaliacao por imagem

    Energy Technology Data Exchange (ETDEWEB)

    Montandon, Cristiano; Teixeira, Kim-Ir-Sen Santos [Clinicas da Imagem e Multimagem, Goiania, GO (Brazil); Costa, Marlos Augusto Bitencourt; Carvalho, Tarcisio Nunes; Montandon Junior, Marcelo Eustaquio [Universidade Federal de Goias, Goiania, GO (Brazil). Faculdade de Medicina. Dept. de Diagnostico por Imagem]. E-mail: cmontandon@terra.com.br

    2007-01-15

    Sacroiliitis is a non-infectious inflammatory process involving the sacroiliac joint, and is a diagnostic criterion for seronegative spondyloarthropathies. Imaging methods are of great value for confirming the diagnosis of this condition. The present study is a review of cases included in didactic files and in the literature to illustrate the anatomy, techniques, and main imaging findings in x-ray, computed tomography and magnetic resonance imaging for determining the diagnosis of sacroiliitis, also approaching main differential diagnoses. (author)

  17. Imaging atherosclerosis with hybrid [18F]fluorodeoxyglucose positron emission tomography/computed tomography imaging: what Leonardo da Vinci could not see.

    Science.gov (United States)

    Cocker, Myra S; Mc Ardle, Brian; Spence, J David; Lum, Cheemun; Hammond, Robert R; Ongaro, Deidre C; McDonald, Matthew A; Dekemp, Robert A; Tardif, Jean-Claude; Beanlands, Rob S B

    2012-12-01

    Prodigious efforts and landmark discoveries have led toward significant advances in our understanding of atherosclerosis. Despite significant efforts, atherosclerosis continues globally to be a leading cause of mortality and reduced quality of life. With surges in the prevalence of obesity and diabetes, atherosclerosis is expected to have an even more pronounced impact upon the global burden of disease. It is imperative to develop strategies for the early detection of disease. Positron emission tomography (PET) imaging utilizing [(18)F]fluorodeoxyglucose (FDG) may provide a non-invasive means of characterizing inflammatory activity within atherosclerotic plaque, thus serving as a surrogate biomarker for detecting vulnerable plaque. The aim of this review is to explore the rationale for performing FDG imaging, provide an overview into the mechanism of action, and summarize findings from the early application of FDG PET imaging in the clinical setting to evaluate vascular disease. Alternative imaging biomarkers and approaches are briefly discussed.

  18. O valor da fase sem contraste na tomografia computadorizada do abdome The role of the unenhanced phase in the routine abdominal computed tomography

    Directory of Open Access Journals (Sweden)

    Ana Paula Klautau Leite

    2008-10-01

    Full Text Available OBJETIVO: Determinar o valor agregado da fase sem meio de contraste da tomografia computadorizada do abdome em pacientes sem diagnóstico determinado ou em estadiamento tumoral. MATERIAIS E MÉTODOS: Estudo prospectivo e transversal em 100 pacientes consecutivos submetidos a tomografia computadorizada abdominal sem e com meio de contraste intravenoso. Dois examinadores avaliaram todos os exames, procurando estabelecer, através da fase com meio de contraste intravenoso (primeira análise e posteriormente através da fase sem contraste (segunda análise, o diagnóstico principal e os secundários em função da indicação clínica do exame. Mediu-se a freqüência de mudança diagnóstica decorrente da análise combinada das fases pré- e pós-contraste intravenoso. Casos que tiveram mudança diagnóstica foram avaliados por especialistas clínicos para determinar se implicaria mudanças de conduta. RESULTADOS: Diagnósticos principal e secundário foram modificados em 1 e 18 casos, respectivamente (p = 1,000; p = 0,143. Os diagnósticos modificados foram: esteatose, definição de nódulo em adrenal, nefrolitíase, classificação de cistos renais e calcificação hepática. Nos casos em que a fase sem contraste modificou o diagnóstico, os especialistas mudaram sua conduta em 14/19 (73% dos pacientes (p = 0,038. CONCLUSÃO: A fase sem contraste não modificou significativamente o diagnóstico principal ou secundário. Porém, as mudanças nos diagnósticos secundários influenciaram na conduta adotada pelos especialistas.OBJECTIVE: To determine the role of the unenhanced phase of abdominal computed tomography in patients without a definite diagnosis or undergoing tumor staging. MATERIALS AND METHODS: A prospective and transversal study was developed with 100 consecutive patients submitted to unenhanced and contrast-enhanced abdominal computed tomography. Two observers evaluated all the computed tomography images in the contrast-enhanced phase

  19. Nonoperative treatment of splenic trauma: usefulness of computed tomography; Tratamento conservador do trauma esplenico: utilidade da tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Resende, Vivian [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Faculdade de Medicina; Tavares Junior, Wilson Campos; Vieira, Jose Nelson Mendes [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Hospital das Clinicas. Dept. de Radiologia e Diagnostico por Imagem]. E-mail: wilsontavaresjrmd@yahoo.fr; Drumond, Domingos Andre Fernandes [Hospital Joao XXIII, Belo Horizonte, MG (Brazil). Setor de Clinica Cirurgica

    2005-04-15

    Objective: to report the results of use of conservative treatment in patients with splenic trauma and to emphasize the usefulness of computed tomography in these cases. Material and method: sixty-nine cases of pediatric patients with blunt abdominal trauma seen from from January 2001 to June 2004 at the level I trauma center were retrospectively studied. Forty-four of these patients were submitted to nonoperative treatment and the clinical follow-up was performed by computerized tomography. All patients had been diagnosed with splenic injury by computerized tomography.Results: the causes of the injuries were motor vehicle accident in 12 (27.2%) patients, bicycle accident in nine (20.4%) patients, and falls in 23 (52.2%) patients. Two (3.7%) patients died from associated injuries. The mean duration of hospital stay was six days. The mean age of the patients was nine years. Conclusion: conservative treatment for blunt splenic trauma is performed with the aim of reducing costs and risks for the patients, and computerized tomography should be routinely used. No posterior complications were observed in this approach. (author)

  20. Using Optical Coherence Tomography to Reveal the Hidden History of The Landsdowne Virgin of the Yarnwinder by Leonardo da Vinci and Studio.

    Science.gov (United States)

    Targowski, Piotr; Iwanicka, Magdalena; Sylwestrzak, Marcin; Frosinini, Cecilia; Striova, Jana; Fontana, Raffaella

    2018-03-07

    Optical coherence tomography (OCT) was used for non-invasive examination of a well-known, yet complex, painting from the studio of Leonardo da Vinci in combination with routine imaging in various bands of electromagnetic radiation. In contrast with these techniques, OCT provides depth-resolved information. Three post-processing modalities were explored: cross-sectional views, maps of scattering from given depths, and their 3D models. Some hidden alterations of the painting owing to past restorations were traced: retouching and overpainting with their positioning within varnish layers as well as indications of a former transfer to canvas. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Unusual computed tomography findings and complications in acute appendicitis; Aspectos tomograficos incomuns da apendicite aguda e suas complicacoes

    Energy Technology Data Exchange (ETDEWEB)

    Palacio, Glaucia Andrade e Silva; D' Ippolito, Giuseppe [Hospital Sao Luiz, Sao Paulo, SP (Brazil). Setor de Diagnostico por Imagem]. E-mail: glauciapalacio@uol.com.br; Bianco, Fabio Davolio [Hospital Sao Luiz, Sao Paulo, SP (Brazil). Setor de Tomografia Computadorizada e Ressonancia Magnetica; Domenicis Junior, Osvaldo de [CURA Imagem e Diagnostico, Sao Paulo, SP (Brazil)

    2003-07-01

    The objective of this article is to describe and illustrate unusual computed tomography (CT) findings in patients with acute appendicitis. We reviewed the charts of 200 patients with clinical suspicion of acute appendicitis who were submitted to abdominal CT before surgery. Patients with unusual presentation or complications were selected for illustrating the main CT findings. Unusual complications of acute appendicitis were related to anomalous position of the appendix, contiguity to intraperitoneal organs such as the liver, gall bladder, annexes and the bladder and continuous use of anti inflammatory or antibiotics during the diagnostic process. We concluded that CT is a useful diagnostic tool in patients with complicated or unusual presentation acute appendicitis. The first step towards diagnosis in these cases i to have in mind the hypothesis of appendicitis in patients with acute abdominal pain. (author)

  2. Aspectos clínico-tomográficos da mucocele com invasão orbitária Clinical and computed tomography aspects of mucocele with orbital invasion

    Directory of Open Access Journals (Sweden)

    Mary Lúcia Bedran

    2003-08-01

    Full Text Available OBJETIVO: Avaliar e relacionar os achados clínico-radiológicos da mucocele orbitária. MÉTODOS: Análise clínica e de imagem referente a 166 pacientes com lesões expansivas da órbita examinadas com o tomógrafo Somaton DR da marca Siemens de terceira geração num período de 10 anos consecutivos em Hospital Universitário de referência. RESULTADOS: Os achados clínicos mais comuns foram tumoração e proptose do globo ocular. À tomografia computadorizada, o achado típico foi de massa com baixa densidade, originando-se em seios paranasais, com destruição óssea adjacente, invasão da órbita e deslocamento do globo ocular. CONCLUSÃO: O desenvolvimento da tomografia computadorizada foi decisivo no estudo da órbita pois propicia, por meio de exame radiológico altamente especializado, imagens de incrível fidelidade anatômica revelando informações sobre o processo patológico como sua localização, sua relação com as estruturas adjacentes e sua vascularização.PURPOSE: To analyze and establish clinical-radiological findings of orbital mucocele. METHODS: Clinical analysis and image of 166 patients with expansive orbital lesions submitted to third generation Siemens Somaton DR computed tomography from February 1986 to February 1995. RESULTS: The most common clinical findings were mass and proptosis. On computed tomography, the typical finding was mass with low density, coming from paranasal sinuses presenting adjacent bone destruction and orbital invasion, with displacement of ocular globe. CONCLUSION: The development of computed tomography was an important mark in orbital studies because it allows incredible anatomic imagings, yielding information about the pathologic process like its localization and anatomic relation.

  3. Estudo da síndrome de tração macular vítreo-retiniana idiopática por meio da tomografia de coerência óptica: relato de casos A study of idiophatic vitreomacular traction syndrome with optical coherence tomography images: cases report

    Directory of Open Access Journals (Sweden)

    Hélio Paulo Primiano Júnior

    2007-02-01

    Full Text Available OBJETIVOS: Avaliar alterações estruturais observadas na síndrome de tração macular vítreo-retiniana idiopática (STMI pela tomografia de coerência óptica (OCT, antes e depois da vitrectomia; identificar situações em que a tomografia de coerência óptica fornece informações adicionais da morfologia e patogênese desta doença. MÉTODOS: Imagens tomográficas (OCT Stratus comparativas da estrutura vítreo-retiniana foram realizadas em quatro pacientes, em estágios variados da síndrome de tração macular vítreo-retiniana idiopática. RESULTADOS: A tomografia de coerência óptica Stratus apresenta imagens vítreo-retinianas que auxiliam na conduta e tratamento da síndrome de tração macular vítreo-retiniana idiopatica. CONCLUSÃO: O exame da tomografia de coerência óptica permite boa visualização da arquitetura morfológica do vítreo e da retina na síndrome de tração macular vítreo-retiniana idiopática. Este exame nos auxilia na compreensão da patogênese, no planejamento do tratamento, clínico ou cirúrgico, e na avaliação pós-operatória das alterações estruturais retinianas.PURPOSE: To evaluate the features of idiophatic vitreomacular traction syndrome (VMT with ocular coherence tomography (OCT - Stratus, before and after vitrectomy; to identify situations where ocular coherence tomography provides additional information on disease morphology and pathogenesis. METHODS: Comparative retinal ocular coherence tomography imaging was performed in four patients with different stages of vitreomacular traction syndrome. RESULTS: Standard-resolution ocular coherence tomography Stratus provides vitreous-retinal images that help the management and treatment of vitreomacular traction syndrome. CONCLUSIONS: Standard-resolution ocular coherence tomography allows good visualization of the architectural morphology of the vitreous and retina in vitreomacular traction syndrome. It helps understanding its pathogenesis, planning

  4. Avaliação da concordância interobservador na análise da tomografia computadorizada sem contraste no diagnóstico da urolitíase em pacientes com cólica renal aguda Interobserver agreement on non-contrast computed tomography interpretation for diagnosis of urolithiasis in patients with acute flank pain

    Directory of Open Access Journals (Sweden)

    Luís Ronan Marquez Ferreira de Souza

    2006-10-01

    Full Text Available OBJETIVO: Avaliar a reprodutibilidade da tomografia computadorizada sem contraste na avaliação da litíase ureteral e os sinais secundários de obstrução do sistema coletor em pacientes com cólica renal aguda. MATERIAIS E MÉTODOS: Estudo prospectivo de 52 pacientes com diagnóstico clínico de cólica renal aguda submetidos a exame de tomografia computadorizada de abdome sem contraste. Os exames foram realizados com técnica helicoidal e posteriormente analisados por três observadores independentes, com a concordância interobservador avaliada pelo método estatístico kappa (kapa. Foram analisados os parâmetros: a presença, localização e mensuração dos cálculos ureterais; b dilatação do sistema coletor intra-renal; c heterogeneidade da gordura perirrenal; d dilatação ureteral; e edema da parede ureteral (sinal do halo. RESULTADOS: Foram encontrados 40 cálculos ureterais na tomografia computadorizada (77%. A concordância interobservador para a identificação do cálculo ureteral e da dilatação ureteral foi quase perfeita (kapa = 0,89 e kapa = 0,87, respectivamente, substancial para dilatação do sistema coletor intra-renal (kapa = 0,77 e moderada para heterogeneidade da gordura perirrenal e para edema da parede ureteral (kapa = 0,55 e kapa = 0,56, respectivamente. CONCLUSÃO: A tomografia computadorizada de abdome sem contraste apresenta elevada reprodutibilidade na avaliação da litíase ureteral e dos sinais secundários de obstrução do sistema coletor.OBJECTIVE: To evaluate the interobserver agreement on non-contrast computed tomography interpretation by a group of experienced abdominal radiologists, for the study of urolithiasis in patients presenting acute flank pain. MATERIALS AND METHODS: Prospective study of 52 patients submitted to non-contrast enhanced helical computed tomography. The images were subsequently analyzed by three independent observers, with the interobserver agreement assessed by means of the

  5. Synthesis and evaluation of translocator 18 kDa protein (TSPO) positron emission tomography (PET) radioligands with low binding sensitivity to human single nucleotide polymorphism rs6971.

    Science.gov (United States)

    Zanotti-Fregonara, Paolo; Zhang, Yi; Jenko, Kimberly J; Gladding, Robert L; Zoghbi, Sami S; Fujita, Masahiro; Sbardella, Gianluca; Castellano, Sabrina; Taliani, Sabrina; Martini, Claudia; Innis, Robert B; Da Settimo, Federico; Pike, Victor W

    2014-10-15

    The imaging of translocator 18 kDa protein (TSPO) in living human brain with radioligands by positron emission tomography (PET) has become an important means for the study of neuroinflammatory conditions occurring in several neuropsychiatric disorders. The widely used prototypical PET radioligand [(11)C](R)-PK 11195 ([(11)C](R)-1; [N-methyl-(11)C](R)-N-sec-butyl-1-(2-chlorophenyl)-N-methylisoquinoline-3-carboxamide) gives a low PET signal and is difficult to quantify, whereas later generation radioligands have binding sensitivity to a human single nucleotide polymorphism (SNP) rs6971, which imposes limitations on their utility for comparative quantitative PET studies of normal and diseased subjects. Recently, azaisosteres of 1 have been developed with improved drug-like properties, including enhanced TSPO affinity accompanied by moderated lipophilicity. Here we selected three of these new ligands (7-9) for labeling with carbon-11 and for evaluation in monkey as candidate PET radioligands for imaging brain TSPO. Each radioligand was readily prepared by (11)C-methylation of an N-desmethyl precursor and was found to give a high proportion of TSPO-specific binding in monkey brain. One of these radioligands, [(11)C]7, the direct 4-azaisostere of 1, presents many radioligand properties that are superior to those reported for [(11)C]1, including higher affinity, lower lipophilicity, and stable quantifiable PET signal. Importantly, 7 was also found to show very low sensitivity to the human SNP rs6971 in vitro. Therefore, [(11)C]7 now warrants evaluation in human subjects with PET to assess its utility for imaging TSPO in human brain, irrespective of subject genotype.

  6. Characterization of the anti tumoral activity of the thiosemicarbazones derived from N(4)-methyl-tolyl-2acetylpyridine And 2-pyridinoformamide and its metal complex: evaluation of the radiopharmaceutical potential; Caracterizacao da atividade antitumoral das tiossemicarbazonas derivadas de N(4)-metil-toluil-2-acetilpiridina e 2-piridinoformamida e seus complexos metalicos: avaliacao do potencial radiofarmaceutico

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Paulo Roberto Ornelas da

    2008-07-01

    Thiosemicarbazones have attracted great pharmacological interest because of their biological properties, such as cytotoxic activity against multiple strains of human tumors. The most studied compounds are pyridine-based because of their resemblance to pyridoxal metabolites that attach to co-enzyme B{sub 6}-dependant enzymes. This work aimed the characterization of the anti tumoral effect of N(4)-methyl-tolyl-2-acetylpyridine and 2-pyridinoformamide-derived thiosemicarbazones and the development of a radiopharmaceutical based on a thiosemicarbazone metal complex for positron emission tomography. In the first phase of this study were synthesized twenty-one thiosemicarbazones, derived from N(4)methyl-2 acetylpyridine and 2-pyridine formamide, as well as their metal complexes (Sn, Ga and Cu). Their cytotoxic potential were evaluated against brain and breast tumor cells in vitro. Our results showed all of them presented powerful cytotoxic and antiproliferative activities against glioblastoma multiform and breast adenocarcinoma at very low concentrations (nanomolar range). Morphological alterations characteristic of apoptosis, such as cell shrinkage, chromatin condensation were observed. Copper chloride was used as control and has presented IC50 at millimolar range suggesting that copper complexation with thiosemicarbazone significantly increases (more than 1 million) the anti tumoral effect of this metal. Due to the potent anti tumoral activity of N(4)-methyl-tolyl-2-acetylpyridine derived thiosemicarbazones and the excellent properties of {sup 64}Cu (T{sub 1/2} = 12.7 hours, {beta}{sup +}, {beta}{sup -}, and EC decay), at the second part for this work it was developed a new imaging agent (radiopharmaceutical) for tumor detection by positron emission tomography (PET). The radiopharmaceuticals were produced in the nuclear reactor TRIGA-IPR-R1 from CDTN, via neutron capture reaction {sup 63}Cu (n,{gamma}) {sup 64}Cu, of the copper complex N(4)-ortho-toluyl-2

  7. Aspectos da tomografia computadorizada no linfoma em pacientes abaixo de 20 anos de idade Computed tomography findings in patients less than 20 years old with lymphoma

    Directory of Open Access Journals (Sweden)

    Adriana Moreira Viana Borba

    2007-04-01

    Full Text Available OBJETIVO: Descrever os achados gerais do linfoma em pacientes abaixo de 20 anos de idade e por subtipo histológico. MATERIAIS E MÉTODOS: Estudo retrospectivo do arquivo digital de tomografia computadorizada do Centro de Controle do Câncer do Hospital Universitário Pedro Ernesto da Universidade do Estado do Rio de Janeiro, no período de março de 2003 a julho de 2005. Dos 22 casos - 16 do sexo masculino e 6 do sexo feminino, com média de idade de 11,5 anos -, 12 eram do subtipo Hodgkin e 10 eram não-Hodgkin. RESULTADOS: Dos achados gerais, verificamos as linfonodomegalias mediastinais como o mais freqüente (59%, com predomínio no grupo Hodgkin (75%, seguido por hepatoesplenomegalia (50% e linfonodomegalias cervicais e retroperitoneais (27,3%. No subtipo Hodgkin houve predomínio do acometimento linfonodal, em sucessivas cadeias, seguido pela hepatoesplenomegalia (50%. Verificamos um caso de massa tonsilar unilateral, opacidade pulmonar em "vidro-fosco" e nódulos renais. No subtipo não-Hodgkin houve predomínio extranodal caracterizado por hepatoesplenomegalia (50%, espessamento de alça intestinal (40%, derrame pleural (30%, nódulo pulmonar (20%, ascite (10%, derrame pericárdico (10% e lesões ósseas mistas (10%. CONCLUSÃO: A tomografia computadorizada é de grande valia no diagnóstico, estadiamento e seguimento do linfoma, com achados de alerta como massa linfonodal, notadamente mediastinal, hepatoesplenomegalia, massa unilateral na tonsila e espessamento parietal de alça intestinal.OBJECTIVE: To describe the general findings of lymphoma and their histological patterns in patients less than 20 years old. MATERIALS AND METHODS: Twenty-two cases (16 male and 6 female, mean age 11.5 years from the digital archive of computed tomography at the Cancer Control Center of "Hospital Universitário Pedro Ernesto - Universidade do Estado do Rio de Janeiro", Rio de Janeiro, RJ, Brazil, were retrospectively analyzed in the period between

  8. Decision theory on the quality evaluation of medical images; A teoria da decisao na avaliacao da qualidade da imagem medica

    Energy Technology Data Exchange (ETDEWEB)

    Lessa, Patricia Silva

    2001-10-01

    The problem of quality has been a constant issue in every organization.One is always seeking to produce more, to do it at a lower cost, and to do it with better quality. However, in this country, there is no radiographic film quality control system for radiographic services. The tittle that actually gets done is essentially ad hoc and superficial. The implications of this gap, along with some other shortcomings that exist in process as a whole (the state of the x-ray equipment, the adequate to use in order to obtain a radiography, the quality of the film, the processing of the film, the brightness and homogeneity of the viewing boxes, the ability of the radiologist), have a very negative impact on the quality of the medical image, and, as result, to the quality of the medical diagnosis and therapy. It frequently happens that many radiographs have to be repeated, which leads to an increase of the patient's exposure to radiation, as well as of the cost of the procedure for the patient. Low quality radiographs that are not repeated greatly increase the probability of a wrong diagnosis, and consequently, of inadequate therapeutical procedures, thus producing increased incidence of bad outcomes and higher costs. The paradigm proposed in order to establish a system for the measurement of the image's quality is Decision Theory. The problem of the assessment of the image is studied by proposing a Decision Theory approach. The review of the literature reveals a great concern with the quality of the image, along with an absence of an adequate paradigm and several essentially empirical procedures. Image parameters are developed in order to formalize the problem in terms of Decision Theory, and various aspects of image digitalisation are exposed. Finally, a solution is presented, including a protocol for quality control. (author)

  9. Activity evaluation from different native or irradiated with {sup 60} Co gamma rays snake venoms and their inhibitory effect on Leishmania (Leishmania) amazonensis; Avaliacao da atividade de diferentes venenos de serpentes, nativos ou irradiados, com radiacao gama de {sup 60} Co, quanto ao poder inibitorio do crescimento de Leishmania (Leishmania) amazonensis

    Energy Technology Data Exchange (ETDEWEB)

    Lourenco, Cecilia de Oliveira

    2000-07-01

    Cutaneous leishmaniasis is a disease, caused by Leishmania parasites, that occurs frequently in tropical and sub-tropical regions of the world. Skin lesions that could results in disfiguring aspect characterize it. The treatment is based on few drugs as antimony salts or pentamidine that are toxic with increasing resistance by the parasite. Alternative forms of disease treatment are in constant search, including natural components as snake venoms. Previous studies demonstrate that some components of snake venoms have an inhibitory effect against those parasites, including Leishmania species. Although snake venoms presented high toxicity, several methods have been described to detoxify most or some of their toxic components, with favorable results by the use of gamma irradiation. In this report we tested several native and irradiated snake venoms for inhibitory effect against Leishmania (Leishmania) amazonensis parasite and LLCMK{sub 2} mammalian cells, with enzymatic tests and electrophoresis. There are significant activity in Acanthophis antarcticus, Agkistrodon bilineatus, Bothrops moojeni, Bothrops jararaca, Hoplocephalus stephensi, Naja melanoleuca, Naja mossambica, Pseudechis australis, Pseudechis colletti, Pseudechis guttatus and Pseudechis porphyriacus, venom being inactive Pseudonaja textilis, Notechis ater niger, Notechis scutatus. Oxyuranus microlepidotus and Oxyuranus scutellatus venoms. After 2 KGy of {sup 60}Co irradiation most venom loses significantly their activity. Venoms with antileishmanial activity presented L-amino acid oxidase (L-AO) activity and showed common protein with a molecular weight about 60kDa in SDS-PAGE. These results indicate that L-AO activity in those venoms are probably related with antileishmanial effect. (author)

  10. Multislice helical computed tomography in the evaluation of lumbar spine diseases; Tomografia computadorizada 'multislice' no diagnostico das afeccoes da coluna lombar

    Energy Technology Data Exchange (ETDEWEB)

    Rosemberg, Laercio Alberto; Rios, Adriana Martins; Almeida, Milena Oliveira [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil)]. E-mail: laercio@einstein.br; Garbaccio, Viviane Ladeira; Kim, Nelson Ji Tae; Daniel, Mauro Miguel; Funari, Marcelo Buarque de Gusmao [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil). Dept. de Imagem

    2003-06-01

    Multislice computed tomography has advantages in comparison to conventional computer tomography such as reduction in study time, lower radiation dose, fewer metal artifacts and high quality multiplanar reformatting and three-dimensional reconstructions. We reviewed approximately 300 lumbar spine examinations and selected the most illustrative cases including congenital anomalies, degenerative lesions, spinal infections, neoplasms traumatic injuries, spondylolysis and postoperative changes. In the majority of the cases the high quality multiplanar reformatted and volume reconstructions of multislice computed tomography allowed better evaluation of the lesions, particularly in the cases of complex anatomy (author)

  11. Cerebral toxoplasmosis in AIDS - computerized tomography evaluation; Toxoplasmose cerebral na SIDA - avaliacao por tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Regina Coeli Fonseca [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Hospital Universitario Antonio Pedro. Servico de Radiologia; Narchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia

    1999-06-01

    Cerebral toxoplasmosis is a disease that affects many AIDS's patients. FOr this paper 46 patients with confirmed cases of cerebral toxoplasmosis who did a CT scan between March, 1994 and September, 1997 were examined. Single lesions were found in 28.3% of the patients. The lesions were more frequently detected in the basal ganglia and the frontal lobes. No lesion was larger than 4 cm. As regards the contrast enhancing of the lesions on a CT scan we observed that 54.5% of the lesions had a ring-like contrast enhancing, 36.4% had a nodular contrast enhancing and 6% had a heterogeneous form. After the 21st day of treatment we noticed an improvement in the aspect of the patients'lesions. The improvement of the lesions could be seen through a reduction of the edematous halo, a reduction of the lesion size and a modification in the contrast enhancing on the CT scan. The CT scan was an important method to demonstrate the lesions compatibility enhancing on the CT scan. The CT scan was an important method to demonstrate the lesions compatibility with cerebral toxoplasmosis, as well as to monitor these patients during treatment. (author)

  12. Aspectos da tomografia de coerência óptica na doença de Stargardt: relato de caso Optical coherence tomography aspects of Stargardt's disease: case report

    Directory of Open Access Journals (Sweden)

    Enéias Bezerra Gouveia

    2006-08-01

    Full Text Available O termo fundus flavimaculatus (doença de Stargardt descreve um grupo de distrofias maculares hereditárias caracterizadas por múltiplos "flecks" amarelados em nível do epitélio pigmentar da retina. Os autores descrevem os achados de tomografia de coerência óptica (OCT em paciente portador de doença de Stargardt e sugerem que a OCT tem validade como exame subsidiário no estudo das características da retina de pacientes portadores da doença de Stargardt, embora estudos envolvendo maior número de pacientes sejam indicados para permitir traçar-se o perfil das alterações mais comuns nestes casos.The term fundus flavimaculatus (Stargardt disease describes a group of inherited macular dystrophies characterized by multiple yellow to yellow-white flecks at the level of the retinal pigment epithelium. The authors describe findings in the patient with Stargardt's disease using optical coherence tomography (OCT, and suggest the examination to be valid as subsidiary method in the study of the characteristics of the retina in Stargardt's disease patients, but studies involving a series of patients should be able to show the most frequent findings in these cases.

  13. Multidetector-row helical computed tomography in the evaluation of cervical spine disorders; Tomografia computadorizada multislice no diagnostico das afeccoes da coluna cervical

    Energy Technology Data Exchange (ETDEWEB)

    Rosemberg, Laercio Alberto; Almeida, Milena Oliveira; Rios, Adriana Martins; Garbaccio, Viviane Ladeira; Kim, Nelson Ji Tae; Daniel, Mauro Miguel; Funari, Marcelo Buarque de Gusmao [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil). Dept. de Imagem]. E-mail: laercio@einstein.br

    2003-07-01

    Multidetector-row computed tomography (MRCT) has advantages in comparison to conventional helical computed tomography, such as reduction of study time, lower radiation doses, fewer metallic artifacts and high quality multiplanar reformatting and three dimensional reconstructions. We reviewed 150 cervical spine examinations and selected the most illustrative cases including congenital anomalies, degenerative lesions, spinal infections, neoplasms, traumatic injuries and postoperative abnormalities. The quality of multiplanar reformatting and volume reconstructions of the MRCT made the detection and evaluation of most of cases with complex anatomy easier and more precise. (author)

  14. Pneumocystis carinii pneumonia in acquired immunodeficiency syndrome - correlation of high-resolution computed tomography and anatomopathology; Pneumocistose na sindrome da imunodeficiencia adquirida: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson; Moreira, Luiza Beatriz [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@zipmail.com.br; Capone, Domenico [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Patologia; Pereira, Cyntia Inez Guedes Soares

    2001-12-01

    We present the main findings observed on the high-resolution computed tomography examinations of 15 patients with acquired immunodeficiency syndrome and Pneumocystis carinii pneumonia. The high-resolution computed tomography and autopsy findings of 5 patients were also compared. The most frequently observed high-resolution computed tomography patterns were ground-glass attenuation, consolidation areas, crazy-paving pattern and cysts. Nodules and intralobular reticulation were less frequently observed. Ground-glass attenuation and consolidation areas corresponded to alveolar filling with inflammatory exudate. Thickening of the interlobular septa was due to cell infiltration and edema. One patient presented interlobular reticulation, and the pathology study revealed alveolar septa thickening due to cell infiltration and fibrosis. Nodules observed in one of the patients corresponded to a patchy intra alveolar accumulation of microorganisms and inflammatory cells forming a 'granulomatous' pattern. (author)

  15. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography; Diagnostico da esteatose hepatica pela tomografia computadorizada de abdome com meio de contraste intravenoso

    Energy Technology Data Exchange (ETDEWEB)

    Monjardim, Rodrigo da Fonseca; Costa, Danilo Manuel Cerqueira; Romano, Ricardo Francisco Tavares; Salvadori, Priscila Silveira; Santos, Jaime de Vargas Conde dos; Atzingen, Augusto Castelli Von; Shigueoka, David Carlos; D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Universidade Federal de Sao Paulo (EPM/UNIFESP), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem

    2013-05-15

    Objective: to evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and methods: in the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 Multiplication-Sign (0.75 Multiplication-Sign P + 0.25 Multiplication-Sign A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results: the simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion: The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity. (author)

  16. Diffuse lung neoplasms. Correlation between high resolution computerized tomography and anatomopathology; Neoplasias pulmonares difusas: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Irion, Klaus L. [Complexo Hospitalar Santa Casa de Porto Alegre, RS (Brazil). Servico de Radiologia do Pavilhao Pereira Filho; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto, SP (Brazil)]. E-mail: edmarchiori@zipmail.com.br

    2002-08-01

    A short comparative evaluation study between high resolution computerized tomography and anatomopathologic findings is presented. The association of these two diagnostic techniques is discussed as a factor to enhance the accuracy of diffuse lung diseases, such as carcinomatous lymphangitis, Kaposi's Sarcoma, lymphomas, hematogenic metastases, bronchiole-alveolar carcinoma and leukemia. (MAC)

  17. SPECT for smokers brain perfusion evaluation; SPECT para avaliacao da perfusao cerebral em fumantes

    Energy Technology Data Exchange (ETDEWEB)

    Maliska, C.M.; Martins, E.F.; Barros, D.S.; Lopes, M.M.S.; Lourenco, C.; Goncalves, S.; Goncalves, M.B.; Miranda, M.M.B.G.; Neto, L.M.; Penque, E.; Antonucci, J.B. [Instituto Nacional do Cancer, Rio de Janeiro, RJ (Brazil)

    2002-07-01

    Cigarette smoking increases brain stroke risk, however,five to fifteen years after ceasing this habit, brain perfusion recovers normal pattern. We propose to compare brain perfusion patterns performing brain SPECT scans of smokers and non-smokers. Thirteen volunteers age range 20-30 years old) composed of six non-smokers and seven smokers were studied by brain scans (SPECT).We used ECD- {sup 99m} Tc radiolabelled as recommended by the manufacturer. All patients received 740 MBq of the radiopharmaceutical through intravenous injection, with their eyes opened and their ears unplugged, in a quiet room. We used a one head SPECT camera ( General Electric/ StarCam 4000 and Siemens/ E.Cam) with low-energy ultrahigh resolution collimator. Imaging begin 40 minutes after tracer injection. For reconstruction we used a Butterworth filter.The preliminary results showed brain perfusion deficit areas on five of the smokers while all non- smokers had normal brain perfusion scans. We believe that smoking increases the possibility of brain perfusion deficits. (author)

  18. Integrity assessment of pipelines - additional remarks; Avaliacao da integridade de dutos - observacoes adicionais

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Luis F.C. [PETROBRAS S.A., Salvador, BA (Brazil). Unidade de Negocios. Exploracao e Producao

    2005-07-01

    Integrity assessment of pipelines is part of a process that aims to enhance the operating safety of pipelines. During this task, questions related to the interpretation of inspection reports and the way of regarding the impact of several parameters on the pipeline integrity normally come up. In order to satisfactorily answer such questions, the integrity assessment team must be able to suitably approach different subjects such as corrosion control and monitoring, assessment of metal loss and geometric anomalies, and third party activities. This paper presents additional remarks on some of these questions based on the integrity assessment of almost fifty pipelines that has been done at PETROBRAS/E and P Bahia over the past eight years. (author)

  19. Avaliacao da gestao ambiental dos hoteis de selva na Amazonia, Brasil

    Directory of Open Access Journals (Sweden)

    Gomes de Moraes, Adriana

    2008-10-01

    Full Text Available In the challenge of desvelar of that it forms the hoteleiros enterprises they manage its ambient action without causing great impacts in one of biggest ecosystems of the world, the Amazonian forest, was tried to know in this research the forms of ambient management of the located hotels of forest in the legal Amazônia. The norteadora question of the research was to know that type of ambient management is made by the hotels of selva?Foi used as instrument of collection of data the questionnaire, that if subdividiui in four great subjects to be searched. The first one was relative questions to the planning of the place, according to to the profile of the customer, third to the room and the relative questions architecture the building subject relative questions to the energy resources and infrastructure of the public services. As result of this analysis was concluded that two of three hotels searched are practising management ambient of form less impactante, since type of construction adopted until services offered to guests, or either shows objective that its hotel is coadjuvante for customer that visits this type of place, that stops it does not import luxury, comfort and amenities, more yes contact with the fauna and flora and way of life of the natives.

  20. Quality evaluation of blood irradiation process;Avaliacao da qualidade do processo de irradiacao de hemocomponentes

    Energy Technology Data Exchange (ETDEWEB)

    Goto, R.E.; Medeiros, R.B. [Universidade Federal de Sao Paulo (DDI/UNIFESP), SP (Brazil). Dept. de Diagnostico por Imagem. Coordenadoria de Fisica e Higiene das Radiacoes

    2009-07-01

    An adverse reaction in blood transfusion is the graft versus host disease (GVHD). This disease affects immunodeficient or immunosuppressed patients where transfused T cells proliferate and initiate a host's immune system reaction. Blood gamma irradiation is the most efficient way to inhibit lymphocyte T blastic transformation and mitotic activity and it is the most effective method to combat this disorder. However, there is no fast and effective system to analyze the dose distribution in the irradiation process and guarantee that the absorbed doses are in agreement with FDA recommendations. This study aims to establish a periodic quality control of the gammacell irradiators using radiochromic films properly calibrated. The quality control is simply and effective to combat GVHD as well as is useful to detect mechanical fails at rotation set system through the dose uniformity analysis. It was possible to verify the uniformity ranged from -72.38% to 106.33% and some blood bag received doses not compatible with recommended international threshold. (author)

  1. Crystallinity evaluation of polyhydroxybutyrate and polycaprolactone blends; Avaliacao da cristalinidade de blendas de polihidroxibutirato e policaprolactona

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcante, Maxwell P.; Rodrigues, Elton Jorge R.; Tavares, Maria Ines B., E-mail: maxdpc@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Instituto de Macromoleculas

    2015-07-01

    Polyhydroxybutyrate, PHB, is a polymer obtained through bacterial or synthetic pathways. It has been used in the biomedical field as a matrix for drug delivery, medical implants and as scaffold material for tissue engineering. PHB has high structural organization, which makes it highly crystalline and brittle, making biodegradation difficult, reducing its employability. In order to enhance the mechanical and biological properties of PHB, blends with other polymers, biocompatible or not, are researched and produced. In this regard, blends of PHB and polycaprolactone, PCL, another biopolymer widely used in the biomedical industry, were obtained via solution casting and were characterized by X-ray diffraction (XRD), differential scanning calorimetry (DSC) and low field nuclear magnetic resonance (LF-NMR). Results have shown a dependence between PHB's crystallinity index and PCL quantity employed to obtain the blends.(author)

  2. Evaluation of occupational exposure in intraoral radiography; Avaliacao da dose ocupacional em radiografia intraoral

    Energy Technology Data Exchange (ETDEWEB)

    Miguel, Cristiano; Barros, Frieda S.; Rocha, Anna S.P.S.; Godoi, Walmor C., E-mail: miguel_cristianoch@yahoo.com.br, E-mail: saicla@utfpr.edu.br, E-mail: annarocha@yahoo.com, E-mail: walmor.godoi@gmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Tilly Junior, Joao G., E-mail: joao.tilly@derax.com.br [Universidade Federal do Parana (HC/UFPR), Curitiba, PR (Brazil). Hospital das Clinicas

    2014-07-01

    The intraoral radiography is widely performed in the dental office due to low cost and agility. The doses in intraoral radiology are considered low, however it is known that doses below the threshold for deterministic radiation has the potential to induce stochastic effects. An intraoral radiography has a risk of inducing fatal cancer or serious in order of 1:10,000,000. Besides the patient, the dentist may also be being exposed to radiation during the work with the radiographics practices. The bibliographies demonstrates the lack of information on radiation protection of dentists, however, the occupational dose reduction was observed in radiology over the past 14 years. This work aims to evaluate the effective dose of radiation to which workers can be exposed dentists in dental offices to perform intraoral radiographs. In this context, a study was be conducted between June 2013 and May 2014 with 44 professionals in Curitiba city. For each dentist was given a personal dosimeter to be used for 30 days. During this period, the number of radiographies and the length of the cable triggers of the X-ray equipment was registered and, the dosimeter´s dose was read. It was observed that the cables triggers meet regulatory standards and allow dentists to get the mean minimum distance of two meters from the radiation source in 93% of cases. Through analysis of the doses, it was concluded that occupational exposures of these workers are within the recommended threshold by regulatory 453/1998 of the Ministry of Health from Brazil. (author)

  3. Imaging assessment of osteitis pubis; Avaliacao por imagem da osteite pubica

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Alexia Abuhid; Ferreira, Ana Paula Alves; Leite, Ana Rachel Albuquerque de Moura; Guido, Daniela Araujo; Rodrigues, Rogeria Nobre [Axial Centro de Imagem, Belo Horizonte, MG (Brazil)]. E-mail: ce@cidbh.com.br; Araujo, Rodrigo Otavio Dias [Minas Tenis Clube, Belo Horizonte, MG (Brazil); Lasmar, Rodrigo Campos Pace [Faculdade de Ciencias Medicas de Minas Gerais, Belo Horizonte, MG (Brazil). Curso de Fisioterapia

    2005-10-15

    Objective: to assess the physiopathological aspects of osteitis pubis and the findings seen on imaging methods, emphasizing the usefulness of Flamingo view radiographs and the diagnostic aspects of Magnetic resonance images. Material and Method: magnetic resonance images of ten patients (eight of them professional athletes) referring symptoms in the inguinal regional were retrospectively evaluated. For some of these patients Flaming view radiographs were performed. Results: in all studied patients magnetic resonance imaging was the only diagnostic method capable of showing the different phases os osteitis pubis, from acute cases with pubic bone marrow edematous changes to chronic cases with involvement of other pelvic joints. Flamingo view radiographs were performed in six patients and three of them were diagnosed with vertical pubis symphyseal instability greater than 2 mm of vertical displacement. This diagnosis was confirmed by instability tests using orthopedic manoeuvres. Conclusion: magnetic resonance imaging was the most helpful method for the diagnosis of different phases of osteitis pubis whereas conventional X-ray was inconclusive in the initial phases. Flamingo view radiographs were extremely important to show vertical instability of the pubic symphysis, which in combination with osteitis pubis can be the cause of failure of nonoperative treatment. (author)

  4. Magnetomotive colon elastography: preliminary assessment; Elastografia magnetomotriz da regiao do colon: avaliacao preliminar em phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Bruno, A. Colello, E-mail: alexandrecolellobruno@usp.br [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina; Grillo, F.W.; Sampaio, D.R.T.; Carneiro, A.A.O. [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia Ciencias e Letras

    2015-08-15

    Colorectal cancer (CRC) is the third most common malignant neoplasm worldwide and early diagnosis reduces morbidity. The standard preventive exams methods are uncomfortable for the patient, invasive, and /or are ionizing. Here, we evaluate the potential of magneto-motive ultrasound (MMUS) as a new, minimally invasive CRC screening technique. We developed a hybrid transducer (comprised of an ultrasound probe and a magnetic coil system) to construct relative elastography maps in a paraffin phantom with isoechoic inclusions. The electromagnetic component of our system manipulated ferromagnetic fluid located inside of our synthetic colon, and the captured ultrasound images were used to produce relative elastography maps. The MMUS images reveal by otherwise invisible structures based on differences in stiffness. Ultrasound elastography (relative) images by MMUs technique complements usual preventive CRC exams, is minimally invasive, has relative low cost when compared with others image methods. Also is fast diagnose and more comfortable for patient which prevents withdrawal of the screening. (author)

  5. Proposta para padronização do relatório de tomografia computadorizada nos aneurismas da aorta abdominal A proposal for standardizing computed tomography reports on abdominal aortic aneurysms

    Directory of Open Access Journals (Sweden)

    Fabiola Goda Torlai

    2006-08-01

    Full Text Available OBJETIVO: Propor um modelo de padronização de relatório para aneurisma da aorta abdominal na tomografia computadorizada. MATERIAIS E MÉTODOS: Foram realizadas, no período de abril a outubro de 2004, entrevistas com integrantes da Disciplina de Cirurgia Vascular da nossa instituição, para elaboração de um modelo de padronização de relatório de tomografia computadorizada para o estudo do aneurisma da aorta abdominal. A partir deste modelo foi elaborado um questionário, enviado a nove outros cirurgiões, todos com experiência em cirurgia da aorta abdominal. O índice de resposta aos questionários foi de 55,5% (5/9. RESULTADOS: Os parâmetros de interesse citados mais freqüentemente para a avaliação dos aneurismas de aorta abdominal foram: diâmetro máximo do colo proximal, extensão do colo proximal até a artéria renal mais baixa, forma do colo proximal, diâmetro máximo do aneurisma e diâmetro das artérias ilíacas comuns. Estes dados permitiram elaborar uma proposta de modelo para padronização de relatório na tomografia computadorizada. CONCLUSÃO: Um modelo para a análise tomográfica padronizada do aneurisma de aorta abdominal permite atender às necessidades dos cirurgiões vasculares para acompanhar a evolução e planejar o tratamento destes pacientes.OBJECTIVE: To propose a model to standardize computed tomography reports on abdominal aortic aneurysms. MATERIALS AND METHODS: Interviews were carried out with members of Vascular Surgery Division of our institution, in the period between April and October 2004, aiming at developing a standardized model of computed tomography reports on abdominal aortic aneurysms. Based on this model, a questionnaire was elaborated and sent to other nine surgeons, all of them experienced in the field of abdominal aortic surgery. The questionnaires response rate was 55.5% (5/9. RESULTS: The most frequently mentioned parameters of interest for evaluation of abdominal aortic aneurysms

  6. Cone beam computed tomography in veterinary dentistry: description and standardization of the technique; Tomografia computadorizada de feixe conico na odontologia veterinaria: descricao e padronizacao da tecnica

    Energy Technology Data Exchange (ETDEWEB)

    Roza, Marcello R. [Universidade Federal de Goias (UFG), Goianai, GO (Brazil)], e-mail: marcelloroza@gmail.com; Silva, Luiz A.F.; Fioravanti, Maria C. S. [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Escola de Veterinaria. Dept. de Medicina Veterinaria; Januario, Alessandro L. [International Team for Implantology (ITI), Sao Paulo, SP (Brazil); Barriviera, Mauricio [Universidade Catolica de Brasilia (UCB), DF (Brazil). Faculdade de Odontologia. Dept. de Radiologia; Oliveira, Alexandre C.A. [Faculdade de Odontologia Sao Leopoldo Mandic, Campinas, SP (Brazil)

    2009-08-15

    Eleven dogs and four cats with buccodental alterations, treated in the Centro Veterinario do Gama, in Brasilia, DF, Brazil, were submitted to cone beam computed tomography. The exams were carried out in a i-CAT tomograph, using for image acquisition six centimeters height, 40 seconds time, 0.2 voxel, 120 kilovolts and 46.72 milli amperes per second. The ideal positioning of the animal for the exam was also determined in this study and it proved to be fundamental for successful examination, which required a simple and safe anesthetic protocol due to the relatively short period of time necessary to obtain the images. Several alterations and diseases were identified with accurate imaging, demonstrating that cone beam computed tomography is a safe, accessible and feasible imaging method which could be included in the small animal dentistry routine diagnosis. (author)

  7. Computed tomography of the adrenals in patients with tuberculosis; Emprego da tomografia computadorizada na deteccao de alteracoes das adrenais em doentes com tuberculose

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Seizo; Machado, Jussara Marcondes; Morceli, Jose [UNESP, Botucatu, SP (Brazil). Faculdade de Medicina. Dept. de Doencas Tropicais e Diagnostico por Imagem]. E-mail: seizo_eid@uol.com.br

    2004-06-01

    We evaluated the adrenals of individuals without tuberculosis (group 1 - G1) and with tuberculosis (group 2 - G2) using computed tomography. The antero-posterior length, the thickness, and the longitudinal length of the adrenals were compared in G1 and G2. The duration of the disease, the occurrence of morphologic abnormalities in G2, the distribution according to sex, age and skin color were also studied. There was difference in the antero-posterior length and thickness of right adrenal between G1 and G2. A higher prevalence of white skin male individuals was observed in G2. There was no association between duration of the disease and the occurrence of morphologic abnormalities in G2. A higher occurrence of adrenal enlargement was observed in G2. The main computed tomography findings in patients with tuberculosis were enlargement of the adrenal without calcification, enlargement of the adrenal with punctiform calcifications, and residual calcification of the adrenal. (author)

  8. Paracoccidioidomycosis: high-resolution computed tomography - anatomo-pathological correlation; Paracoccidioidomicose: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson; Muniz, Maria Angelica Soares; Santos, Maria Lucia de Oliveira [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Radiologia; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Patologia; Capone, Domenico [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Pneumologia

    2000-12-01

    We reviewed the high-resolution computed tomography scans of 13 patients with paracoccidioidomycosis and correlated the findings with the anatomo-pathological findings of 5 patients. The most frequent findings observed were thickening of the interlobular septa, emphysema, ground glass areas, thickening of bronchial walls, tracheal dilatation, nodules, cavities and evidence of fibrosing disease such as architectural distortion, parenchymatous bands, spicular pleural thickening, intralobular reticulate and thickening with distortion off the axial interstitium. (author)

  9. Fournier gangrene: report of three cases, computed tomography imaging findings and literature review;Gangrena de Fournier: relato de tres casos, achados tomograficos e revisao da literatura

    Energy Technology Data Exchange (ETDEWEB)

    Judici, Paola Lima Pasini; Christofoli, Maria Olivia Jacques de Medeiros; Oliveira, Paulo Cesar Rocha; Teles, Ilailson de Goes; Najjar, Yana Senna Jeronimo, E-mail: paolajudice@sarah.b [Rede Sarah de Hospitais de Reabilitacao, Brasilia, DF (Brazil)

    2010-08-15

    The authors report three cases of patients with Fournier gangrene. This is a polymicrobial infectious disease that affects the perineum and genitalia, especially in males, whose source is most commonly genitourinary, colorectal or cutaneous and may also not have a clearly defined focus. Potentially lethal, requires immediate clinical and surgical treatment. The purpose of this report is to describe the main findings of imaging on computed tomography in this disease and to briefly review the literature on the subject. (author)

  10. Aspects of pulmonary histiocytosis X on high resolution computed tomography; Aspectos da histiocitose X pulmonar na tomografia computadorizada de alta resolucao (TCAR)

    Energy Technology Data Exchange (ETDEWEB)

    Costa, N.S.S.; Castro Lessa Angela, M.T. de; Angelo Junior, J.R.L.; Silva, F.M.D.; Kavakama, J.; Carvalho, C.R.R. de; Cerri, G.G. [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Hospital das Clinicas. Inst. do Coracao

    1995-01-01

    Pulmonary histiocytosis X is a disease that occurs in young adults and presents with nodules and cysts, mainly in upper lobes, with consequent pulmonary fibrosis. These pulmonary changes are virtually pathognomonic findings on high resolution computed tomography, that allows estimate the area of the lung involved and distinguish histiocytosis X from other disorders that also produces nodules and cysts. (author). 10 refs, 2 tabs, 6 figs.

  11. Computerized tomography

    International Nuclear Information System (INIS)

    Rubashov, I.B.

    1985-01-01

    Operating principle is described for the devices of computerized tomography used in medicine for diagnosis of brain diseases. Computerized tomography is considered as a part of computerized diagnosis, as a part of information science. It is shown that computerized tomography is a real existed field of investigations in medicine and industrial production

  12. Melanotic neuroectodermal tumor of infancy (progonoma): a case report emphasizing the computed tomography findings and literature review; Tumor neuroectodermico melanocitico da infancia (progonoma): relato de caso enfatizando os aspectos tomograficos e revisao da literatura

    Energy Technology Data Exchange (ETDEWEB)

    Araujo Junior, Cyrillo Rodrigues de; Carvalho, Tarcisio Nunes; Fraguas Filho, Sergio Roberto; Costa, Marlos Augusto Bitencourt; Borba, Ana Olivia Cardoso; Figueiredo, Sizenildo da Silva; Machado, Marcio Martins; Teixeira, Kim-Ir-Sen Santos [Goias Univ., Goiania, GO (Brazil). Hospital das Clinicas. Servico de Diagnostico por Imagem]. E-mail: radiologia@brturbo.com

    2004-12-01

    The melanotic neuroectodermal tumor of infancy, also known as progonoma, is a rare benign disease of neural crest origin that occurs within the first year of life and affects mainly the maxilla. The authors report a case of a 10-month-old child presenting with this uncommon tumor in the maxilla, emphasizing the diagnostic findings on computed tomography, and present a literature review. (author)

  13. Computed tomography findings in patients less than 20 years old with lymphoma; Aspectos da tomografia computadorizada no linfoma em pacientes abaixo de 20 anos de idade

    Energy Technology Data Exchange (ETDEWEB)

    Borba, Adriana Moreira Viana [Pontificia Universidade Catolica do Rio de Janeiro (PUC-RJ), Rio de Janeiro, RJ (Brazil). Escola de Medicina; Monteiro, Alexandra Maria Vieira; Lucena, Stella Beatriz Goncalves de [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Faculdade de Ciencias Medicas; Lima, Claudio Marcio Amaral de Oliveira; Ribeiro, Erica Barreiros [Hospital Naval Marcilio Dias, Rio de Janeiro, RJ (Brazil)]. E-mail: cmaol@br.inter.net; Skinner, Luis Flavio [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Faculdade de Ciencias Medicas. Hospital Universitario Pedro Ernesto (HUPE)

    2007-03-15

    Objective: To describe the general findings of lymphoma and their histological patterns in patients less than 20 years old. Materials And Methods: Twenty-two cases (16 male and 6 female, mean age 11.5 years) from the digital archive of computed tomography at the Cancer Control Center of Hospital Universitario Pedro Ernesto - Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, Brazil, were retrospectively analyzed in the period between March 2003 and July 2005. Of these 22 cases, 12 were Hodgkin's and 10 were non-Hodgkin's. Results: Overall, mediastinal lymphadenomegaly was the most frequent finding (59%), with predominance in the Hodgkin's subgroup (75%), followed by hepatosplenomegaly (50%) and cervical and retroperitoneal lymphadenomegaly (27.3%). The Hodgkin's subgroup presented a prevalence of lymphadenopathy, in many lymph node chains, followed by hepatosplenomegaly (50%). One case was found with unilateral tonsillar mass, pulmonary ground-glass opacities, and renal nodules. In the non-Hodgkin's subgroup, the disease was predominantly extranodal, characterized by hepatosplenomegaly (50%), thickening of the intestinal wall (40%), pleural effusion (30%), pulmonary nodule (20%), ascites (10%), pericardial effusion (10%) and mixed bone lesions (10%). Conclusion: Computed tomography is an extremely useful method for detection, staging and follow-up of lymphomas, with alert findings like mediastinal lymphadenopathy, hepatosplenomegaly, unilateral tonsillar mass and thickening of intestinal wall. (author)

  14. Local behavior and lymph node metastases of Wilms' tumor: accuracy of computed tomography; Comportamento local e metastases linfonodais do tumor de Wilms: acuracia da tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Eduardo Just da Costa e, E-mail: eduardojust@oi.com.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Instituto Materno Infantil de Pernambuco (IMIP), Recife, PE (Brazil); Silva, Giselia Alves Pontes da [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. Maternal Infantil

    2014-01-15

    Objective: to evaluate the accuracy of computed tomography for local and lymph node staging of Wilms' tumor. Materials and methods: each case of Wilms' tumor was evaluated for the presence of abdominal lymph nodes by a radiologist. Signs of capsule and adjacent organ invasion were analyzed. Surgical and histopathological results were taken as the gold standard. Results: sensitivity was 100% for both mesenteric and retroperitoneal lymph nodes detection, and specificity was, respectively, 12% and 33%, with positive predictive value of 8% and 11% and negative predictive value of 100%. Signs of capsular invasion presented sensitivity of 87%, specificity of 77%, positive predictive value of 63% and negative predictive value of 93%. Signs of adjacent organ invasion presented sensitivity of 100%, specificity of 78%, positive predictive value of 37% and negative predictive value of 100%. Conclusion: computed tomography tumor showed low specificity and low positive predictive value in the detection of lymph node dissemination. The absence of detectable lymph nodes makes their presence unlikely, and likewise regarding the evaluation of local behavior of tumors. (author)

  15. Determination of the initial energy in computerized tomography with proton beams; Determinacao da energia inicial em tomografia computadorizada com feixe de protons

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Rodrigo Luis da

    2007-07-01

    In earliest works devoted to proton computed tomography it was shown that the advantage of pCT image reconstruction appears when the energy is close to the Bragg peak region, since the proton passes the object. This effect provided by the Bragg peak makes the computerized tomography with protons possible. However, when decreasing the initial proton energy, with the increase of the irradiation dose, there are two effects that work simultaneously in opposite ways. First, the energy loss of a proton in an object becomes bigger at small initial energy. At the same time decreasing of the proton energy results in the increase of the energy straggling, requiring a larger number of protons. In this work the radiation dose dependence on the proton initial energy was studied using analytical formulas and computer simulations. The investigation determined that the radiation dose practically does not depend on the initial energy, except in the energy region very close to the minimum energy necessary to pass the object. (author)

  16. Synthesis and evaluation of antimalarial activity of curcumin derivatives; Sintese e avaliacao da atividade antimalarica de compostos derivados da curcumina

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Patricia Ramos; Miguel, Fabio Balbino; Almeida, Mauro Vieira de; Couri, Mara Rubia Costa [Universidade Federal de Juiz de Fora (UFSJ), MG (Brazil). Instituto de Ciencias Exatas. Departamento de Quimica; Oliveira, Michael Eder de; Ferreira, Vanessa Viana; Guimaraes, Daniel Silqueira Martins; Lima, Aline Brito de; Barbosa, Camila de Souza; Oliveira, Mariana Amorim de; Almeida, Mauro Vieira de; Viana, Gustavo Henrique Ribeiro; Varotti, Fernando de Pilla, E-mail: varotti@ufsj.edu.br [Universidade Federal de Sao Joao Del Rei (UFSJ), MG (Brazil). Centro de Ciencias da Saude; others, and

    2014-05-15

    ne of the main challenges in the development of new antimalarial drugs is to achieve a viable lead candidate with good pharmacokinetic properties. Curcumin has a broad range of biological activities, including antimalarial activity. Herein, we report the antimalarial activity of six curcumin derivatives (6-12) and an initial analysis of their pharmacokinetic properties. Five compounds have demonstrated potent activity against the P. falciparum in vitro (IC{sub 50} values ranging from 1.7 to 15.2 μg mL{sup -1}), with moderate or low cytotoxicity against the HeLa cell line. The substitution of the carbonyl group in 6 by a 2,4-dinitrophenylhydrazone group (to afford 11) increases the Selective Index. These preliminary results indicate curcumin derivatives as potential antimalarial compounds. (author)

  17. Evaluation of the numerical solution of polymer flooding; Avaliacao da solucao numerica da injecao de polimeros em reservatorios de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Vinicius Ligiero; Pires, Adolfo Puime; Bedrikovetsky, Pavel G. [Universidade Estadual do Norte Fluminense (UENF), Macae, RJ (Brazil). Lab. de Engenharia e Exploracao do Petroleo (LENEP)

    2004-07-01

    Enhanced Oil Recovery (EOR) methods include injection of different fluids into reservoirs to improve oil displacement. The EOR methods may be classified into the following kinds: injection of chemical solutions, injection of solvents and thermal methods. The chemical fluids most commonly injected are polymers, surfactants, micellar solutions, etc. Displacement of oil by any of these fluids involves complex physico-chemical processes of interphase mass transfer, phase transitions and transport properties changes. These processes can be divided into two main categories: thermodynamical and hydrodynamical ones. They occur simultaneously during the displacement, and are coupled in the modern mathematical models of EOR. The model for one-dimensional displacement of oil by polymer solutions is analyzed in this paper. The Courant number is fixed, and we compare the results of different runs of a numerical simulator with the analytical solution of this problem. Each run corresponds to a different spatial discretization. (author)

  18. Retinal thickness measurement and evaluation of natural history of the diabetic macular edema through optical coherence tomography Medida da espessura retiniana e avaliação da história natural do edema macular diabético pela tomografia de coerência óptica

    Directory of Open Access Journals (Sweden)

    Rosana Zacarias Hannouche

    2009-08-01

    influence on the center point thickness data, whereas values of visual acuity were significantly correlated with it. CONCLUSION: This study presents the optical coherence tomography applicability in the detection and semiologic evaluation of diabetic macular edema in patients with visual acuity 20/40 or greater, during one year, showing the retinal thickening in the early stages of diabetic retinopathy. Further, it evidenciated the correlation between the increase in foveal thickness and the reduction in visual acuity. Levels of hemoglobin A1c did not influence the center point thickness data. An early detection of clinically significant macular edema leads us to a redefinition of the real meaning of incipient retinopathy and can prevent further significant reduction of vision.OBJETIVOS: 1 Diagnosticar a presença de edema macular diabético em pacientes com retinopatia diabética e acuidade visual igual ou melhor que 20/40, pela realização do exame de tomografia de coerência óptica, medindo a espessura foveal central, ao longo de um ano. 2 Avaliar a história natural do edema, ao longo de um ano, associando a espessura foveal central com a hemoglobina glicosilada (HbA1c e alterações na acuidade visual. 3 Correlacionar os resultados obtidos com o grupo controle. MÉTODOS: Estudo prospectivo de uma amostra de 30 pacientes, com edema macular diabético e acuidade visual melhor ou igual a 20/40. O estudo contou com 30 olhos como grupo controle. Foram feitas medidas da melhor acuidade visual corrigida, dosagem de hemoglobina glicosilada, biomicroscopia com lente de 78 dioptrias, angiofluoresceinografia e tomografia de coerência óptica. Determinou-se, pelo propósito do estudo, a espessura foveal central como principal variável. Além da estatística descritiva, utilizaram-se testes para análise dos resultados: foi testada a homogeneidade de cada variável pelos testes t-Student, Qui-Quadrado e teste de Tukey; para correlacionar variáveis utilizou-se a análise de

  19. A tomografia computadorizada de alta resolução na avaliação da toxicidade pulmonar por amiodarona High-resolution computed tomography of amiodarone pulmonary toxicity

    Directory of Open Access Journals (Sweden)

    Daniela Peixoto Consídera

    2006-04-01

    Full Text Available OBJETIVO: Avaliar as principais alterações identificadas na tomografia computadorizada de alta resolução do tórax em pacientes com toxicidade pulmonar pela amiodarona. MATERIAIS E MÉTODOS: Foram avaliadas dez tomografias computadorizadas de alta resolução de tórax de pacientes com pneumonite pela amiodarona, seis desses pacientes do sexo masculino e quatro do sexo feminino, com idade média de 73,5 anos. RESULTADOS: Os achados tomográficos mais relevantes foram opacidades lineares ou reticulares em seis casos (60%, pequenos nódulos com densidade elevada em seis casos (60%, consolidações densas em três casos (30% e aumento da densidade do parênquima hepático em cinco de oito casos em que havia estudo tomográfico do abdome superior (62,5%. CONCLUSÃO: A tomografia computadorizada de alta resolução é um exame importante na avaliação de pacientes com toxicidade pulmonar pela amiodarona, devendo ser realizada sempre que houver suspeita deste diagnóstico. O achado de espessamento de septos interlobulares associado a lesões com aumento de densidade é altamente sugestivo deste diagnóstico.OBJECTIVE: To evaluate the main findings of chest high-resolution computed tomography in patients with amiodarone pulmonary toxicity. MATERIALS AND METHODS: Ten patients - six male and four female, average age of 73.5 years - with amiodarone-induced pneumonitis have undergone chest high-resolution computed tomography. RESULTS: The most relevant tomographic findings were linear or reticular opacities in six cases (60%, small high density nodules in six cases (60%, dense consolidations in three cases (30% and increased density in the hepatic parenchyma in five of eight cases in which there was a superior abdomen CT scan (62.5%. CONCLUSION: The high-resolution computed tomography is a valuable non-invasive test for evaluating patients with amiodarone pulmonary toxicity and should always be performed when one suspects of the presence of this

  20. Experimental study of mechanisms of sand production using X-ray computerized tomography; Estudo experimental dos mecanismos da producao de areia empregando tomografia computadorizada de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Janaina B.; Vargas Junior, Euripedes [Pontificia Univ. Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. de Engenharia Civil; Barroso, Emilio V. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Geologia; Campos, Elisabete; Goncalves, Clemente; Tavares, Andre [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES)

    2004-07-01

    During productive phase of the well, many times there is simultaneous production of the solid particles detached from matrix of the reservoir rock. This phenomenon receives the name of the sand production. In this case stress and flow conditions around of the well are fundamental factors for deflagration of the process. Stress concentration in the wall of the well lead to the loss of cohesion between grains arising, consequently, a granular material region susceptible for dragging by seepage forces derived from fluid flow. The objective of this work was to perform sand production tests in Rio Bonito and synthetic sandstone samples using real-time X-Ray Computerized Tomography. The tests investigated the initial and the evolution of failure at the cavity wall of samples. These are initial stages of the sand production process. The analysis of the CT-scans obtained during tests allowed the visualization of breakouts and collapses of the wells. From studies more details were possible estimate the sand production and produce 3-D images of the propagation of the failure. (author)

  1. The potential of carbon-11 and fluorine-18 chemistry: illustration through the development of positron emission tomography radioligands targeting the translocator protein 18 kDa

    International Nuclear Information System (INIS)

    Damont, Annelaure; Roeda, Dirk; Dolle, Frederic

    2013-01-01

    The TSPO (translocator protein), also known as the peripheral benzodiazepine receptor, is up-regulated in the brain of subjects suffering from neuro-degenerative disorders such as Alzheimer's, Parkinson's and Huntington's disease. Moreover, this overexpression has been proved to be linked to micro-glia activation making thus the TSPO a marker of choice of neuro-inflammatory processes and therefore a potential target for the development of radioligands for positron emission tomography imaging. The discovery of selective TSPO ligands and their labelling with the short-lived positron-emitter isotopes carbon-11 and fluorine-18 emerged in the mid-1980's with the preparation of the 3-iso-quinolinecarboxamide [ 11 C]PK11195. To date, an impressive number of promising compounds - [ 11 C]PK11195-challengers - have been developed; some radioligands - for example, [ 11 C]PBR28, [ 11 C]DPA-713, [ 18 F]FEDAA1106 and [ 18 F]DPA-714 - are currently used in clinical trials. As illustrated in this review, the methodologies applied for the preparation of these compounds remain mainly [ 11 C]methylations using [ 11 C]MeI or [ 11 C]MeOTf and SN2- type nucleophilic aliphatic [ 18 F]fluorinations - two processes illustrating the state-of-the-art arsenal of reactions that involves these two short-lived radioisotopes - but alternative processes, such as [ 11 C]carbonylations using [ 11 C]CO and [ 11 C]COCl 2 as well as SNAr-type nucleophilic [ 18 F]fluorinations, have also been reported and as such, reviewed herein. (authors)

  2. Computed Tomography of gunshot wounds to the head. Personal experience in 23 cases. Ferite da arma da fuoco del cranio osservate con Tomografia Computerizzata. Esperienza personale in 23 casi

    Energy Technology Data Exchange (ETDEWEB)

    Salzano, A.; De Rosa, A. (Ospedale Loreto Mare, Neaples (Italy). Servizio di Radiologia); Scialpi, M. (Ospedale Civile SS. Annunziata, Taranto (Italy). Unita' Operativa di Radiodiagnostica, Sez. di Tomografia Computerizzata); Rossi, E.; Carbone, M.; Brunese, L. (Neaples Univ. Federico 2, Neaples (Italy). Ist. di Scienze Radiologiche); Nocera, V. (Ospedale A. Cardarelli, Naples (Italy). Servizio di Radiologia); Muto, M. (Azienda di Rilievo Nazionale A. Cardarelli, Neaples (Italy). Servizio di Neuroradiologia)

    Gunshot wounds to the head are usually mortal injures. Their frequency has been increasing in the last years because of increasing crime rates. Emergency Computed Tomography (CT) makes a useful tool for depicting bullet course and brain damage, and thus helps plan treatment. It has been investigated on the CT signs of subdural hematoma, lacerocontusive focus, subarachnoid hemorrhage, hemoencephalus, skull bone fracture and thecal hollow and report them as an aid to the neurosurgeon and the radiologist, for best treatment planning, and in an attempt to establish use prognostic criteria. It has been reviewed 23 cases of gunshot injuries to the head studied with CT at the Emergency Unit of Loreto Mare 2048ital in Naples, Italy. Twenty patients were men and 3 women; their mean age was 31 years (range: 18-49). Three women and 2 men had been injured accidentally by wandering bullets, and one case was an attempted suicide; all the other cases resulted from shootings. It was found 22 penetrating gunshot wounds: 13 of them with thecal entry hole and intracranial bullet retention and 9 with an entry and exit hole. One case was a superficial wound. Crash skull fractures were seen in 22 cases and they were fragmented in 12, with overlapping thecal fragments in 4, and with deep fragments in 2 cases. Gunshot wounds to the head are complex and severe traumas with high mortality rates because of both early and late effects and complications. CT provides the neurosurgeon with abundant findings for diagnosis and surgical planning, which may result in improved survival rates. In these patients emergency CT plays a fundamental diagnostic role in depicting brain damage and thus remains the method of choice for thorough, rapid and accurate brain and skull studies, as well as to detect possible injury to the chest and abdomen.

  3. Positron emission tomography imaging of the 18-kDa translocator protein (TSPO) with [18F]FEMPA in Alzheimer's disease patients and control subjects

    International Nuclear Information System (INIS)

    Varrone, Andrea; Oikonen, Vesa; Joutsa, Juho; Solin, Olof; Haaparanta-Solin, Merja; Rinne, Juha O.; Forsberg, Anton; Takano, Akihiro; Nag, Sangram; Nakao, Ryuji; Halldin, Christer; Al-Tawil, Nabil; Wells, Lisa A.; Rabiner, Eugenii A.; Valencia, Ray; Schultze-Mosgau, Marcus; Thiele, Andrea; Vollmer, Sonja; Dyrks, Thomas; Lehmann, Lutz; Heinrich, Tobias; Hoffmann, Anja; Nordberg, Agneta

    2015-01-01

    Imaging of the 18-kDa translocator protein (TSPO) is a potential tool for examining microglial activation and neuroinflammation in early Alzheimer's disease (AD). [ 18 F]FEMPA is a novel high-affinity second-generation TSPO radioligand that has displayed suitable pharmacokinetic properties in preclinical studies. The aims of this study were to quantify the binding of [ 18 F]FEMPA to TSPO in AD patients and controls and to investigate whether higher [ 18 F]FEMPA binding in AD patients than in controls could be detected in vivo. Ten AD patients (five men, five women; age 66.9 ± 7.3 years; MMSE score 25.5 ± 2.5) and seven controls (three men, four women; age 63.7 ± 7.2 years, MMSE score 29.3 ± 1.0) were studied using [ 18 F]FEMPA at Turku (13 subjects) and at Karolinska Institutet (4 subjects). The in vitro binding affinity for TSPO was assessed using PBR28 in a competition assay with [ 3 H]PK11195 in seven controls and eight AD patients. Cortical and subcortical regions of interest were examined. Quantification was performed using a two-tissue compartment model (2TCM) and Logan graphical analysis (GA). The outcome measure was the total distribution volume (V T ). Repeated measures analysis of variance was used to assess the effect of group and TSPO binding status on V T . Five AD patients and four controls were high-affinity binders (HABs). Three AD patients and three controls were mixed-affinity binders. V T estimated with Logan GA was significantly correlated with V T estimated with the 2TCM in both controls (r = 0.97) and AD patients (r = 0.98) and was selected for the final analysis. Significantly higher V T was found in the medial temporal cortex in AD patients than in controls (p = 0.044) if the TSPO binding status was entered as a covariate. If only HABs were included, significantly higher V T was found in the medial and lateral temporal cortex, posterior cingulate, caudate, putamen, thalamus and cerebellum in AD patients than in controls (p 18 F

  4. Evaluation of the thermoluminescent detector answers of CaSO{sub 4}:Dy, LiF:Mg,Ti and micro LiF:Mg,Ti in photon clinical beams dosimetry using water simulator; Avaliacao da resposta de detectores termoluminescentes de CaSO4:Dy, LiF:Mg,Ti e microLiF:Mg,Ti na dosimetria de feixes clinicos de fotons utilizando simulador de agua

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Luciana C.; Veneziani, Glauco R.; Campos, Leticia L., E-mail: lmatsushima@usp.b, E-mail: veneziani@ipen.b, E-mail: lcrodri@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (GMR/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Gerencia de Metrologia das Radiacoes; Sakuraba, Roberto K.; Cruz, Jose C. da, E-mail: rsakuraba@einstein.b, E-mail: jccruz@einstein.b [Sociedade Beneficente Israelita Brasileira, Sao Paulo, SP (Brazil). Hospital Albert Einstein (HAE)

    2011-10-26

    This paper perform the comparative study of thermoluminescent answer of calcium sulfate dosemeter doped with dysprosium (DaSO{sub 4}:Dy) produced by the IPEN, Sao Paulo, with answer of lithium fluoride dosemeters doped with magnesium and titanium (LiF:Mg, Ti) in the dosimetry of clinical beams of photons (6 and 15 MV) by using water simulator object. Dose-answer curves were obtained for gamma radiation of cobalt-60 in the air and in conditions of electronic equilibrium (plate of PMMA), and clinical photons of CLINAC model 2100C accelerators of the two evaluated hospitals: Hospital das Clinicas of the Faculty of Medicine of Sao Paulo university and Hospital Albert Einstein. It was also evaluated the sensitivity and reproduction of the three dosemeters

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  6. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  7. Optical tomography of tissues

    International Nuclear Information System (INIS)

    Zimnyakov, D A; Tuchin, Valerii V

    2002-01-01

    Methods of optical tomography of biological tissues are considered, which include pulse-modulation and frequency-modulation tomography, diffusion tomography with the use of cw radiation sources, optical coherent tomography, speckle-correlation tomography of nonstationary media, and optoacoustic tomography. The method for controlling the optical properties of tissues is studied from the point of view of increasing a probing depth in optical coherent tomography. The modern state and prospects of the development of optical tomography are discussed. (review)

  8. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  9. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  10. Contribuição da tomografia de coerência óptica de 820 nm na distrofia granular corneana: relato de caso Contribution of 820 nm optical coherence tomography in granular corneal dystrophy: case report

    Directory of Open Access Journals (Sweden)

    Beatriz de Abreu Fiuza Gomes

    2008-10-01

    Full Text Available O objetivo deste trabalho é correlacionar os dados clínicos de um caso de distrofia granular com o exame de tomografia de coerência óptica (OCT de 820 nm de modo a determinar o nível intra-estromal dos depósitos corneanos. É relatado um caso de distrofia granular em paciente de 38 anos do sexo masculino. Foi realizado exame oftalmológico completo e OCT para documentação do caso. O aparelho utilizado foi o Stratus OCT III, originalmente desenvolvido para avaliação do segmento posterior. A acuidade visual corrigida foi de 20/50 em ambos os olhos. À biomicroscopia, foram observadas opacidades em "floco de neve" em diferentes níveis do estroma corneano bilateral e de forma simétrica. A avaliação pelo OCT revelou múltiplos pontos hiperreflectivos nas camadas superficiais e profundas do estroma. Foi possível acessar a anatomia morfológica da córnea através de cortes seriados realizados pelo Stratus OCT III e confirmar a profundidade dos depósitos corneanos.The purpose of this case report is to correlate clinical features of granular dystrophy using 820 nm optical coherence tomography (OCT in order to determine the depth of intrastromal corneal deposits. We report a case of a 38-year-old man with granular dystrophy. After complete ophthalmologic examination the patient was submitted to OCT, using the Stratus OCT III, originally proposed for studying disorders of the posterior segment. Best-corrected visual acuity was 20/50 in both eyes. Biomicroscopy revealed bilateral "snowflake"opacities in different levels of the stromal layer. OCT disclosed multiple hiperreflective dots in anterior and deeper stromal layers. It was possible to assess the morphology of the cornea and to determine the depth of the corneal deposits with serial cross-sectional OCT scans using the Stratus OCT III.

  11. Imaging micro-glial/macrophage activation in spinal cords of experimental autoimmune encephalomyelitis rats by Positron Emission Tomography using the mitochondrial 18 kDa translocator protein radioligand [18F]DPA-714

    International Nuclear Information System (INIS)

    Abourbeh, Galith; Theze, Benoit; Dubois, Albertine; Tavitian, Bertrand; Boisgard, Raphael; Maroy, Renaud; Brulon, Vincent; Fontyn, Yoann; Dolle, Frederic

    2012-01-01

    Multiple sclerosis (MS) is an inflammatory demyelinating disease of the CNS. Activated micro-glia/macrophages play a key role in the immuno-pathogenesis of MS and its corresponding animal models, experimental autoimmune encephalomyelitis (EAE). Micro-glia activation begins at early stages of the disease and is associated with elevated expression of the 18 kDa mitochondrial translocator protein (TSPO). Thus, positron emission tomography (PET) imaging of micro-glial activation using TSPO-specific radioligands could be valuable for monitoring disease-associated neuro-inflammatory processes. EAE was induced in rats using a fragment of myelin basic protein, yielding acute clinical disease that reflects extensive spinal cord inflammation. Enhanced TSPO expression in spinal cords of EAE rats versus those of controls was confirmed by Western blot and immunohistochemistry. Biodistribution studies in control and EAE rats were performed using the TSPO radioligand [ 18 F]DPA-714 [N,N-diethyl-2-(2-(4-(2-fluoroethoxy)phenyl)-5,7-dimethylpyrazolo[1,5- a]pyrimidin-3-yl)acetamide]. At 1 h after injection, almost fivefold higher levels of [ 18 F]DPA-714 were measured in spinal cords of EAE rats versus controls. The specific binding of [ 18 F]DPA-714 to TSPO in spinal cords was confirmed in competition studies, using unlabeled (R,S)-PK11195 [(R,S)-N-methyl-N-(1-methylpropyl)-1-(2-chlorophenyl) - isoquinoline-3-carboxamide)] or DPA-714 in excess. MicroPET studies affirm that this differential radioactivity uptake in spinal cords of EAE versus control rats could be detected and quantified. Using [ 18 F]DPA-714, neuro-inflammation in spinal cords of EAE-induced rats could be visualized by PET, offering a sensitive technique for monitoring neuro-inflammatory lesions in the CNS and particularly in the spinal cord. In addition to current MRI protocols, this approach could provide molecular images of neuro-inflammation for detection, monitoring, and research in MS. (authors)

  12. Evaluation of the crude oil viscosity variation in function of the demulsifiers addition; Avaliacao da variacao da viscosidade de oleo cru em funcao da adicao de desemulsificante

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Jansen M.; Lucas, Elisabete F. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Macromoleculas]. E-mail: elucas@ima.ufrj.br; Neves, Guilherme B.M. [COMAB Especialidades Quimicas Ltda., Rio de Janeiro, RJ (Brazil)]. E-mail: tecnico@comabrio.com

    2003-07-01

    One way of improving well production is the addition of demulsifier already in the gas lift. This is due to the apparent viscosity of water-in-oil emulsions being higher than apparent viscosity of crude oil, which in turn is higher than the apparent viscosity of an water-in-oil dual phase admixture and is also higher than the apparent viscosity of an oil-in-water emulsion. However, there are some situations where, in order to obtain separate flows of oil and water phases, demulsifier should be added in specific amounts in order to promote the desired phase separation. In heavy oils water and oil phase separation may be hard to obtain, however, the right demulsifier amount may imply in a considerable decrease in petroleum viscosity even without the appearance of two phases, making the flow easier. This work has evaluated the viscosity of a heavy crude having API degree 14 and BSW 52%, as a function of the addition of different amounts of DEMTROL BR 67, manufactured by Dow Quimica/Comab, Brazil, as demulsifier. (author)

  13. Computerized tomography

    International Nuclear Information System (INIS)

    Caille, J.M.; Salamon, G.

    1980-01-01

    As X-ray Ct becomes more commonplace, other techniques of investigation using roughly comparable hardware and software have appeared. Positron-Emission Tomography already provides indispensable physiological and physio-pathological information. Similarly, in the histo-chemical field, Nuclear Magnetic Resonance seems very promising. Some of these new techniques will no doubt shortly be considered as essential as CT in establishing accurate diagnoses non-invasively. (orig./VJ) [de

  14. Computed tomography

    International Nuclear Information System (INIS)

    Andre, M.; Resnick, D.

    1988-01-01

    Computed tomography (CT) has matured into a reliable and prominent tool for study of the muscoloskeletal system. When it was introduced in 1973, it was unique in many ways and posed a challenge to interpretation. It is in these unique features, however, that its advantages lie in comparison with conventional techniques. These advantages will be described in a spectrum of important applications in orthopedics and rheumatology

  15. Halo sign nodules in angio invasive pulmonary aspergillosis: correlation of high-resolution computed tomography findings with anatomopathology; Nodulos com sinal do halo na aspergilose pulmonar angioinvasiva: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Valiante, Paulo Marcos [Universidade Federal, Rio de Janeiro, RJ (Brazil). Dept. de Patologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Disciplina de Radiologia

    2002-08-01

    The aim of this study was to correlate the early findings observed on high-resolution computed tomography with anatomopathology results of patients with angio invasive aspergillosis. The authors studied two patients with leukemia. The nodules seen on high-resolution computed tomography corresponded to areas of hemorrhagic infarction, necrotic coagulation and fungal hyphae infiltration whereas ground glass halo corresponded to intra alveolar hemorrhage. Nodules with halo sign were closely correlated with anatomopathology findings. We concluded that the anatomopathology findings can clearly explain the image features of the lesions observed on high-resolution computed tomography. (author)

  16. Densidade de um planossolo sob sistemas de cultivo avaliada por meio da tomografia computadorizada de raios gama Bulk density of an alfisol under cultivation systems in a long-term experiment evaluated with gamma ray computed tomography

    Directory of Open Access Journals (Sweden)

    Adilson Luís Bamberg

    2009-10-01

    Full Text Available A sustentabilidade do arroz (Oryza sativa L. irrigado em solos de várzea está alicerçada na utilização da rotação e sucessão de culturas, fundamentais para o controle do arroz-vermelho e preto. Os reflexos sobre os atributos dos solos de várzea merecem estudos em especial sobre a compactação do solo. O objetivo deste trabalho foi identificar camadas compactadas em Planossolo submetido a diferentes sistemas de cultivo e preparo, avaliando-se a densidade do solo (Ds pela Tomografia Computadorizada de Raios Gama (TC. A análise foi realizada em um experimento de longa duração, conduzido de 1985 a 2004, na Estação Experimental da Embrapa Clima Temperado, Capão do Leão, RS, num delineamento experimental em blocos ao acaso, com sete tratamentos, cada um com quatro repetições (T1 - um ano de arroz com preparo convencional do solo seguido de dois anos de pousio; T2 - cultivo contínuo de arroz com preparo convencional do solo; T4 - rotação de arroz e soja (Glycine max L. com preparo convencional do solo; T5 - rotação de arroz, soja e milho (Zea maiz L. em preparo convencional do solo; T6 - plantio direto de arroz no verão em sucessão do azevém (Lolium multiflorum L. no inverno; T7 - rotação de arroz sob plantio direto e soja sob preparo convencional do solo; T8 - testemunha: solo sem cultivo. A Tomografia Computadorizada de Raios Gama permitiu detectar que o plantio direto de arroz no verão em sucessão do azevém no inverno não resultou na formação de camadas compactadas; a utilização de dois anos de pousio, no sistema de produção de arroz irrigado, não foi suficiente para evitar a formação de uma camada superficial compactada; e a rotação de arroz, soja e milho com preparo convencional do solo apresentou duas camadas compactadas (0,0 a 1,5 cm e 11 a 14 cm, indicando que essas podem limitar a produção agrícola nesse sistema de produção em Planossolos.The sustainability of irrigated rice (Oryza sativa L. in

  17. Estudo do metabolismo da glicose na tuberculose pulmonar ativa utilizando a tomografia por emissão de pósitrons (18F-FDG PET Evaluation of glucose metabolism in active lung tuberculosis by positron-emission tomography (18F-FDG PET

    Directory of Open Access Journals (Sweden)

    SIDNEY BOMBARDA

    2002-09-01

    Full Text Available Os métodos de imagem utilizados na avaliação da tuberculose pulmonar incluem a radiografia e a tomografia computadorizada do tórax. As imagens obtidas pelos métodos de medicina nuclear permitem estudos funcionais e metabólicos dos órgãos de interesse, através do uso de radiofármacos específicos. Alterações do metabolismo da glicose podem ser detectadas pela tomografia por emissão de pósitrons (PET utilizando-se o 18F-fluorodesoxiglicose (18F-FDG. Essas alterações estão presentes nas doenças neoplásicas, inflamatórias e infecciosas. A tuberculose é uma doença granulomatosa causada pelo Mycobacterium tuberculosis, que se utiliza de glicose como fonte de energia. Objetivo: O estudo do metabolismo da glicose na tuberculose pulmonar através da PET e sua comparação com a tomografia computadorizada de tórax. Material e métodos: Foram avaliados 20 pacientes portadores de tuberculose pulmonar. Todos foram submetidos à PET e à tomografia computadorizada de tórax, em até 30 dias após o início do tratamento. Resultados: Todos os pacientes apresentaram captação positiva do 18F-FDG na PET. Na tomografia computadorizada do tórax, todos os pacientes apresentaram sinais compatíveis com atividade de tuberculose. A sensibilidade dos dois métodos foi de 100%. Houve concordância entre os achados do 18F-FDG PET e da tomografia computadorizada (K = 0,27 e p Current methods to evaluate lung tuberculosis include chest radiography and computed tomography. Nuclear medicine imaging techniques are performed after administration of specific radiopharmaceuticals that accumulate in the organs of interest. Alterations of glucose metabolism can be observed by positron-emission tomography, using 18F-fluorodeoxyglucose (18F-FDG PET. These findings are present in the neoplasms, but also in inflammatory and infectious diseases. Tuberculosis is a granulomatous disease caused by Mycobacterium tuberculosis , that uses glucose as an energy source

  18. Evaluation of the energetic equivalence of goat manure biogas; Avaliacao da equivalencia energetica do biogas de esterco de caprinos

    Energy Technology Data Exchange (ETDEWEB)

    Canafistula, Francisco Jose Firmino; Carvalho, Paulo Cesar Marques de [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Dept. de Engenharia Eletrica], e-mails: firmino@ufc.br, carvalho@dee.ufc.br

    2008-07-01

    The present paper shows the results of a research about a new production system model based on goats; part of the animals manure is used for biogas production. The biogas is used as fuel for water pumping for the irrigation of the animals pasture. For the viability of the project, a photovoltaic powered electrified fence was used. Additional to the positive results of sustainability, innovative solutions were developed for sizing, optimization and costs reduction by the use of digesters in small rural communities of the semi-arid of the Brazilian Northeast Region. (author)

  19. Evaluation of elemental composition of clays from Campos Gerais (MG); Avaliacao da composicao elementar de argilas de Campos Gerais (MG)

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Joao P.M.; Maduar, Marcelo F.; Silva, Paulo S.C da, E-mail: jpmm0697@hotmail.com [Instituto de Pesquisas Energeticas e nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    There are numerous applications given to clays including oil and water adsorbent, ceramic, whitening of beverages, porcelain, waste treatment, organic carrier molecules in cosmetics and pharmaceuticals, support for catalysts. In the pharmaceutical industry, the clays are used as excipients, diluents, desiccants, emulsifiers, to mask undesirable flavors, isotonic agent such as charger and delivery of active substances. These characteristics have contributed to the expansion of the search for applications of clay minerals in the cosmetic industry. The aim of this study was to determine the elemental composition of clays from Campos Gerais, Minas Gerais, with a view to their applicability in the production of cosmetics. The elements As, Ba, Br, Ce, Cl, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Nd, Rb, Sb, Sc, Sm, Ta, Tb, Th,U, Yb and Zn were determined by neutron activation analysis and radionuclide activity concentration of {sup 226}Ra, {sup 228} Ra, {sup 210}Pb and {sup 40}K were determined by gamma spectrometry. It was verified that the activity concentration of radionuclides was in the same concentration as the global average, indicating that these samples do not present a risk of increased radiation exposure. The concentration of most elements determined is less than or equal to the overall mean concentrations, indicated by the values of Continental Upper Crust. (author)

  20. Evaluation of welding by MIG in martensitic stainless steel; Avaliacao da soldagem pelo processo MIG em aco inoxidavel martensitico

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, M.A. [Universidade Estadual de Campinas (UNICAMP), SP (Brazil); Mariano, N.A.; Marinho, D.H.C. Marinho, E-mail: neideaparecidamariano@gmail.co [Universidade Federal de Alfenas (UNIFAL), Pocos de Caldas, MG (Brazil)

    2010-07-01

    This work evaluated structure's characterization and mechanical properties after the welding process of the stainless steel CA6NM. The employed welding process was the metal active gas with tubular wire. The control of the thermal cycle in the welding process has fundamental importance regarding the properties of the welded joint, particularly in the thermally affected zone. The mechanical properties were appraised through impact resistance tests and the hardness and microstructure through metallographic characterization and Ray-X diffraction. The parameters and the process of welding used promoted the hardness and toughness appropriate to the applications of the steel. Welding energy's control becomes an essential factor that can affect the temperature of carbide precipitation and the nucleation of the retained austenite in the in the region of the in the thermally affected zone. (author)

  1. Evaluation of kerma rate in radioactive waste disposal; Avaliacao da taxa de kerma em deposito de rejeitos radioativos

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, Rodolfo O.; Silva, Joao C.P.; Santos, Joao R. dos, E-mail: oliveira@ien.gov.br, E-mail: jcarlos@ien.gov.br, E-mail: regis@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    This study aims to assess the progression of kerma rate levels in the air due to the increase of collection, storing and storage of radioactive waste in the new building (after expansion) of the radioactive waste disposal (RWD) of the Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Brazil. This review is carried out every six months at IEN with thermoluminescent dosimeter lithium fluoride LiF: Mg, Cu, P (TLD-100H). Here are the average values of kerma rate for the period 2008- 2012. In this context, the methodology used for selection and choices of detectors used in dosimeters is presented. The detectors were chosen through homogeneity criteria of the pack, standardization factor and coefficient of variation (CV%). The monitoring points and the exposure time of the detectors are chosen considering various factors, including the rate of occupation and indoor and outdoor positions to RWD. These evaluations showed that the contribution of the new waste disposal in increasing kerma rate of IEN, has proved to be insignificant, that is, the presence of RWD does not contribute to increased environmental kerma rate in the region around this installation.

  2. Evaluation of radioiodinetherapy protocol for patients with Plummer disease; Avaliacao do protocolo da radioiodoterapia para pacientes com doenca de Plummer

    Energy Technology Data Exchange (ETDEWEB)

    Mendonca, Keyla Mary Cavalheiro; Antonio Filho, Joao; Brandao, Simone Cristina Soares, E-mail: keylamcm@yahoo.com.br, E-mail: jaf@ufpe.br, E-mail: simonecordis@yahoo.com.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Santos, Marcus Aurelio P. dos, E-mail: masantos@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2014-07-01

    The disease Plummer (DP) is generated by the thyroid cells that function autonomously, independent the rest of the organ parenchyma. The DP presents a prevalence of 1% to 9%, higher in regions with iodine deficiency, affecting six women for every man. The study was conducted at the Department of Nuclear Medicine of Universidade Federal de Pernambuco (UFPE) from {sup 99m}Tc data capture and mass existing in the thyroid records of 54 patients with PD who underwent radioiodine therapy with fixed activities 1110 megabecquerels (MBq) from 2004 to 2008. For capitation of {sup 99m}Tc from a group of 22 patients were used 5 ml syringes, measured by a Capintec CRC-7 model activimeter, having scintigraphy after 20 minutes and results in a region of interest. Mass evaluation was based on method of palpation of the thyroid, considering the mass standard. It is observed that 68.2% of patients received more activity than needed, 31.8% were less active, and none received activity in accordance with your needs. There was a statistically significant difference (p <0.05) between the fixed activities and activities computed for all patients, according to Chi-square test for independence with 21 degrees of freedom. The cure rate of a group of 32 patients was 75% after one year of follow-up. It is suggested that the RIT is preceded by an assessment of the maximum percentage of uptake and thyroid mass.

  3. Evaluation of the dispersion of oil refinery liquid effluent; Avaliacao da dispersao de efluente liquido de refinaria de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Mariano, Adriano Pinto; Silva, Ariovaldo Jose da; Oliveira, Valdenilson Jose Alves de; Angelis, Dejanira de Franceschi de [Universidade Estadual Paulista (UNESP), Rio Claro, SP (Brazil). Dept. de Bioquimica e Microbiologia. Inst. de Biociencias], e-mail: adrianomariano@yahoo.com.br

    2010-07-15

    In this paper, two techniques to evaluate the dispersion of the effluent of an oil refinery are presented. Thus, the dispersion plume was characterized by field measurements of electrical conductivity and by computational simulation (Cormix simulator). An oil refinery whose effluent is discharged on the Atibaia river (Paulinia/SP) is taken as study case. The behavior of the effluent was evaluated until 1000 m after the discharge. The results show that the measurement of electrical conductivity is a suitable technique to evaluate the dispersion of oil refinery wastewaters, since they have high conductivity and for this reason there is a strong contrast between the values of the wastewater and the ambient background. Furthermore, other water quality parameters had a dispersion behavior similar to that shown by the conductivity. The dispersion plume generated by the computational simulator showed high concordance with the field data. In this manner, computational simulation can be a useful tool to evaluate the dispersion of discharges considering hypothetical scenarios, as well as to design the discharge channel. (author)

  4. Cementing quality evaluation with ultrasonic logs in fiberglass casings; Avaliacao da qualidade do cimento em revestimentos de fibra de vidro

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Wellington; Lazaro, Andre F. [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2008-07-01

    The sonic and ultrasonic profiles are used as the main tools in assessing the cementing quality between formation and casing in oil wells. This assessment is important, because, if there is a failure in the primary cementing, both the structural integrity and zone isolation will be compromised. The sonic profiles are based on the acoustic energy attenuation in casing, cement and formation, while the ultrasonic profiles are based on the resonance of the wave pulse within the media where they travel (casings, cement and formation). The attenuation and resonance are due to the difference in the way the wave travel within these media. The acoustic impedance is the quantification of this difference, determining the refraction and reflection between the environments, and wave attenuation as well. In steel casings, this difference is meaningful, allowing the captured signals (reflected pulses) to be interpreted as good adhesion between cement and casing, or a lack of adhesion at some interval. In fiber glass casings, the impedance contrast between glass and cement is small and not detectable with the CBL/VDL sensors. The CBL/VDL tools provide an inefficient assessment of the quality of the cementing. The ultrasonic profile does not have this problem, theoretically. The goal of this work is to demonstrate and recommend the ultrasonic tool as the main instrument to assess the cementation quality in fiber glass casings. (author)

  5. Evaluation of the ocular protection for low intensity therapeutic lasers; Avaliacao da protecao ocular para lasers terapeuticos em baixa intensidade

    Energy Technology Data Exchange (ETDEWEB)

    Cordon, Rosely

    2003-07-01

    The low intensity laser therapy (LILT) has been extensively used in medicine and dentistry presenting positive effects. However, the laser radiation can also cause adverse effects. Due to the ocular focalization property, in the wavelength from 400 to 1400 nm, the retina is more susceptible to damage by radiation than any other part of the human body. Then, the ocular protection is frequently emphasized. This protection must attenuate the radiation to a safe level. The International Electrotechnical Commission (IEC) standard IEC 60825-1 suggests safety requirements for medical laser equipment, including the ocular protection, based on maximum permissible exposure levels. The Brazilian legislation adopts a corresponding IEC standard, the NBR IEC 601.2.22, for safety requirements. The aim of this study was to analyze the adequacy of the ocular protectors furnished by four laser equipment manufacturers, commercially available in Brazil, commonly used for LILT. For this purpose, the laser equipment and the respective ocular protectors were characterized. The adequacy was verified according to the IEC standards. It was found, among other results, ocular protectors attenuating to safe levels the radiation emitted by the respective laser equipment, however, presenting inadequate visual transmission. Inefficient protection and protection indicated in cases where they were not necessary were also observed. (author)

  6. Evaluation of external exposure in a radioactive waste deposit; Avaliacao da exposicao externa em um deposito de rejeitos radioativos

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Sergio Quinet de; Pereira, Wagner de Souza; Py Junior, Delcy de Azevedo; Dores, Luis Augusto de Carvalho Bresser; Dantas, Marcelino Vicente de Almeida; Silva, Ana Claudia Antunes; Garcia Filho, Oswaldo, E-mail: wspereira@inb.gov.b, E-mail: sergioquinet@inb.gov.b, E-mail: delcy@inb.gov.b, E-mail: luisdores@inb.gov.b, E-mail: marcelino@inb.go.b, E-mail: anasilva@inb.gov.b, E-mail: ogarcia@inb.gov.b [Industrias Nucleares do Brasil (UTM/INB), Pocos de Caldas, MG (Brazil). Unidade de Tratamento de Minerio

    2011-10-26

    The ore treatment unit (OTU) of Industrias Nucleares do Brasil (INB), located at Caldas municipality - Minas Gerais, Brazil, posses a radioactive deposit, coming mainly from the chemical processing of monazite sands for obtention of 'rare earths'. The main components of these waste are the 'torta II (thorium rich residues) and the 'mesothorium' ({sup 228}Ra rich residues) - conditioned in steel drums (200 liters), plastic pumps (100 liters) or underground silos. These loaders are deposited in waste loading warehouses existent at the OTU and periodic evaluations of the external exposure rates (mR/h) are part of the 'Programa de Monitoracao Radiologica Ocupacional' of the unit. This paper presents a brief history of origins of this waste deposit and the material found there, and also the result of a routine monitoring of the external exposure rates

  7. Evaluation of integrity of radiation sources of nuclear gauges; Avaliacao da integridade de fontes radioativas de medidores nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Torohate, Wiclif Francisco

    2016-11-01

    Nuclear equipment meters are mainly used in the industry in quality control and process control. The principle of operation consists in a shielded radioactive source together with a radiation detector such that the radiation interacts with the material to be analyzed before reaching the detector, providing real time data. Can be as their fixed and mobile mobility, the unique properties of ionizing radiation are used in three basic modes, transmission, backscatter or dispersion or induced (reactive). With the advancement and technological modernization in the world, the demand for nuclear gauges becomes increasingly larger. Currently in Brazil there are about 465 process control plants and 21 portable systems and Mozambique about 45 facilities using nuclear gauges. This font registration is done through a process called source inventory that allows also to know the category of the source, the danger or risk to human health that the source offers. The handling of this equipment requires personnel, certified, skilled and well trained in radiation protection area in accordance with the requirements of the various CNEN Rules. Due to the presence of radioactive source and because these devices are used by workers risk because there external radiation. In this context, we made the smear test in two fixed meters from the IRD industry laboratory, which determines the integrity of the source package, mandatory item in periodic integrity testing of the radiation source of this type of device. A set of procedures is made for its implementation as an evaluation of the radiological risk by radiological survey. It was intended to contribute to the learning handling and safe use of these meters. (author)

  8. External exposure assessment in dwelling built with phosphogypsum; Avaliacao da exposicao externa em residencia construida com fosfogesso

    Energy Technology Data Exchange (ETDEWEB)

    Villaverde, Freddy Lazo

    2008-07-01

    In this study it was evaluated the viability of the use of phosphogypsum plates as a building material in the dwelling construction. Thus, the effective dose due to external gamma exposure was assessed through the {sup 226}Ra, {sup 232}Th, {sup 210}Pb e {sup 40}K activity concentration in phosphogypsum plates. Samples of this material were analyzed by high resolution gamma spectrometry for their natural radionuclide activity concentration. The radium equivalent activity and extern ai and inter nai hazard indices were also calculated. The plates were made with phosphogypsum from fertilizer industries located in Cajati, Cubatao and Uberaba. The samples were identified according to phosphogypsum origin, Cajati (CA), Cubatao (CT) and Uberaba (UB). The activity concentrations results varied from 15.9 to 392 Bq kg{sup -1} for {sup 226}Ra, 26.1 to 253 Bq kg{sup -1} for {sup 232}Th, and 27.4 to 852 Bq kg{sup -1} for {sup 210}Pb. The results of {sup 40}K were lower than 81 Bq kg{sup -1}. The annual effective dose was obtained through the dosimetric model with reference standard room concept, the results were 0.02 mSv y{sup -1} for a house built with phosphogypsum from origin CA, 0.2 mSvy{sup -1} for CT phosphogypsum and 0.14 mSvy{sup -1} for UB phosphogypsum, everything the effective doses were below 1 mSvy{sup -1}, an annual effective dose limit for public exposure by International Commission on Radiological Protection. (author)

  9. Optimization of the dose versus noise in the image on protocols for computed tomography of pediatric head;Otimizacao da relacao dose versus ruido na imagem em protocolos de tomografia computadorizada de cranio pediatrico

    Energy Technology Data Exchange (ETDEWEB)

    Saint' Yves, T.L.A.; Travassos, P.C.; Goncalves, E.A.S.; Mecca, F.A.; Silveira, T.B. [Instituto Nacional de Cancer (INCA), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This article aims to establish protocols optimized for computed tomography of pediatric skull, to the Picker Q 2000 tomography of the Instituto Nacional de Cancer, through the analysis of dose x noise on the image with the variation of values of m As and k Vp. We used a water phantom to measure the noise, a pencil type ionization chamber to measure the dose in the air and the Alderson Randon phantom for check the quality of the image. We found values of m As and k Vp that reduce the skin dose of the original protocol used in 35.9%, maintaining the same image quality at a safe diagnosis. (author)

  10. Uso da tomografia de coerência ótica intracoronariana para caracterização precisa da aterosclerose Uso de la tomografía de coherencia óptica intracoronaria para caracterización precisa de la aterosclerosis Use of optical coherence tomography for accurate characterization of atherosclerosis

    Directory of Open Access Journals (Sweden)

    John Coletta

    2010-02-01

    Full Text Available A Tomografia de Coerência Ótica (TCO é uma nova tecnologia de imagem baseada em interferometria de baixa coerência que utiliza a dispersão de luz quase-infravermelha como uma fonte de sinal para fornecer imagens transversais vasculares com definição muito superior à de qualquer outra modalidade disponível. Com uma resolução espacial de até 10μm, a TCO fornece uma resolução 20 vezes maior do que o ultrassom intravascular (USIV, a modalidade atualmente mais utilizada para obter imagens intra-coronárias. A TCO tem uma capacidade de fornecer um entendimento das várias fases da doença aterosclerótica e a resposta vascular ao tratamento. Estudos tem mostrado a capacidade da TCO em detectar estruturas arteriais e ajudar na determinação de diferentes constituintes histológicos. Sua capacidade de distinguir diferentes graus de alterações ateroscleróticas e os vários tipos de placas, quando comparada à histologia, tem sido recentemente demonstrada com correlações inter e intra-observador aceitáveis para esses achados. A TCO fornece uma resolução endovascular excepcional em tempo real in vivo, que tem sido explorada para avaliar as estruturas vasculares e a resposta ao uso do equipamento. Embora a profundidade permaneça uma limitação para a caracterização de placa além de 2 mm através da TCO, uma resolução próxima à histológica pode ser obtida dentro do primeiro milímetro da parede do vaso, permitindo uma avaliação extraordinária das características e espessura da capa fibrosa. Além disso, a avaliação da cobertura de neoíntima, padrões de tecido para-haste e aposição de stent podem agora ser escrutinizados para hastes individuais na escala de mícrons, a assim chamada análise em nível de haste. A TCO levou a imagem intravascular ao nível de mícron na análise vascular in vivo e espera-se que breve se torne uma ferramenta valiosa e indispensável para cardiologistas em aplicações clínicas e de

  11. Photoacoustic Tomography

    Science.gov (United States)

    Wang, Lihong V.

    Photoacoustic tomography (PAT) refers to imaging that is based on the photoacoustic effect. Although the photoacoustic effect as a physical phenomenon was first reported on by Alexander Graham Bell in 1880 [1], PAT as an imaging technology was developed only after the advent of ultrasonic transducers, computers, and lasers [2-31]. A review on biomedical photoacoustics is available [32]. The motivation for PAT is to combine optical-absorption contrast with ultrasonic spatial resolution for deep imaging in the optical quasi-diffusive or diffusive regime. In PAT, the tissue is irradiated by usually a short-pulsed laser beam to achieve a thermal and acoustic impulse response (Fig. 19.1). Locally absorbed light is converted into heat, which is further converted to a pressure rise via thermo-elastic expansion. The initial pressure rise - determined by the local optical absorption coefficient (μ â ), fluence (ψ) and other thermal and mechanical properties - propagates as an ultrasonic wave, which is referred to as a photoacoustic wave.

  12. Axial tomography

    International Nuclear Information System (INIS)

    Brueckner, K.A.; Lewis, J.H.

    1979-01-01

    The invention relates to axial tomography, sometimes referred to as cross-sectional x-ray. The apparatus described may utilize the conventional x-ray or ultrasonic source and detector and scanning mechanism for producing the plurality of sets of radiation detector output signals. It has the means for storing the detector output signals in analog form with the signals of one set overlying the signals of another set so that signals resulting from radiation through a zone of the object being examined are summed at a corresponding zone in the storage device, typically an electronic storage tube. The summed signals are read from the storage device with a radially inversely proportional reader producing a second signal for storage, again typically in an electronic storage tube. These signals stored in the second storage device are read with Laplacian relation, with the resultant sigal being a video signal that may be connected to a TV monitor for display of the sectional image. In alternative embodiments, optical film systems and electrostatic systems are utilized. (JTA)

  13. Optimization on the dose versus noise in the image on protocols for computed tomography of pediatric head; Otimizacao da relacao dose versus ruido na imagem em protocolos de tomografia computadorizada de cranio pediatrico

    Energy Technology Data Exchange (ETDEWEB)

    Saint' Yves, Thalis L.A.; Travassos, Paulo Cesar B.; Goncalves, Elicardo A.S.; Mecca A, Fernando; Silveira, Thiago B. [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil)], e-mail: fmecca@inca.gov.br, e-mail: thalis09@yahoo.com.br

    2010-03-15

    This article aims to establish protocols optimized for computed tomography of pediatric skull, to the Picker Q2000 tomography of the Instituto Nacional de Cancer, through the analysis of dose x noise on the image with the variation of values of mAs and kVp. We used a water phantom to measure the noise, a pencil type ionization chamber to measure the dose in the air and the Alderson Randon phantom for check the quality of the image. We found values of mAs and kVp that reduce the skin dose of the original protocol used in 35.9%, maintaining the same image quality at a safe diagnosis. (author)

  14. Algorithmic fundamentals of computerized tomography and of transverse analogue tomography

    International Nuclear Information System (INIS)

    Heckmann, K.

    1981-01-01

    Computerized tomography and transverse analogue tomography are two different approaches to the same goal, namely, transverse tomography. The algorithm is discussed and compared. Transverse tomography appears capable of further development, judging by this comparison. (orig.) [de

  15. Sarcoma de Kaposi relacionado à síndrome da imunodeficiência adquirida: características do comprometimento hepático na tomografia computadorizada e na ressonância magnética Kaposi sarcoma related to acquired immunodeficiency syndrome: hepatic findings on computed tomography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Daniel Nobrega da Costa

    2008-04-01

    Full Text Available Sarcoma de Kaposi é uma neoplasia associada a condições de imunossupressão que acomete os vasos linfáticos e sanguíneos. É a neoplasia intra-hepática mais comum na síndrome da imunodeficiência adquirida. A tomografia computadorizada e a ressonância magnética revelam múltiplos pequenos nódulos, proeminência e realce dos planos periportais, devido à presença de tecido neoplásico. Os autores descrevem um caso de paciente masculino, de 47 anos de idade, com síndrome da imunodeficiência adquirida e sarcoma de Kaposi disseminado.Kaposi sarcoma is a neoplasm associated with immunosuppressive conditions, and involving blood and lymphatic vessels. It is the most frequent intrahepatic neoplasm in patients with acquired immunodeficiency syndrome. Computed tomography and magnetic resonance imaging demonstrate multiple small nodules, prominence and contrast-enhancement of periportal branches due to the presence of the neoplastic tissue. The authors report a case of a 47-year-old male patient with acquired immunodeficiency syndrome presenting disseminated Kaposi sarcoma.

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  17. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  19. Índices bióticos para avaliação da qualidade ambiental em trechos do rio Correntoso, Pantanal do Negro, Estado do Mato Grosso do Sul, Brasil = Biotic indexes for the evaluation of environmental quality in stretches of the Correntoso river, Pantanal do Negro, Mato Grosso do Sul State, Brazil

    Directory of Open Access Journals (Sweden)

    Fábio Henrique da Silva

    2011-07-01

    Full Text Available Este trabalho teve como objetivo pesquisar a estrutura da comunidade de insetos aquaticos, utilizando esta comunidade como indicadora da qualidade ambiental de um trecho do rio Correntoso, Pantanal do Negro, Mato Grosso do Sul, Brasil. Foram realizadas seis campanhas de coleta em diferentes periodos sazonais: vazante, seca e cheia. Os organismos foram coletados utilizando rede D com malha de 300 ƒÝm eesforco amostral de cinco lances de rede nas raizes dos bancos de macrofitas. Foram comparados tres ambientes (aberto, intermediario e fechado, por juncao dos dados obtidos de seis sitios de coleta. Foi analisada a riqueza, abundancia absoluta e relativa das familias de insetos amostrados e a avaliacao da qualidade da agua usando o indiceBMWP, indice BMWP-ASPT, indice IBF e indice de diversidade de Shannon-Wienner, com log2. Foram registradas 60 familias pertencentes a 12 ordens da Classe Insecta, totalizando 19.773 individuos coletados. Entre os indices aplicados, o indice BMWP foi o que melhor representou as condicoes do ambiente estudado.This work aimed to research the aquatic insect community structure using this community as a bioindicator of the environmental quality in a stretch of the Correntoso river, in Pantanal do Negro, Mato Grosso do Sul, Brazil. Six collections were taken in different seasonal periods; ebb, dry and wet. The organisms were collected using a 300 ƒÝm mesh D net sweeping five times through the roots of macrophyte banks at each sample. Three environments were compared (open, intermediary, closed by adding the information from six collection sites. Family richness, absolute and relative abundance ofinsect samples and an evaluation of water quality were analyzed by using the BMWP index, BMWP-ASPT index, IBF index and Shannon diversity index, with log2. A total of 60 families from 12 orders of Insecta Class were recorded, totaling 19,773 individuals. Among the indexes applied, the BMWP index was the one that best

  20. Review of muon tomography

    International Nuclear Information System (INIS)

    Feng Hanliang; Jiao Xiaojing

    2010-01-01

    As a new detection technology, Muon tomography has some potential benefits, such as being able to form a three- dimensional image, without radiation, low cost, fast detecting etc. Especially, muon tomography will play an important role in detecting nuclear materials. It introduces the theory of Muon tomography, its advantages and the Muon tomography system developed by decision sciences corporation and Los Alamos national laboratory. (authors)

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  2. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  5. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  6. Quality evaluation of Argentina onion irradiated, transported and stored; Avaliacao da qualidade da cebola argentina irradiada, transportada e armazenada no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Walder, J M.M.; Domarco, R E; Spoto, M H.F.; Blumer, L [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil); Curzio, O A; Croci, C A [Universidad Nacional del Sur, Bahia Blanca (Argentina). Lab. de Radioisotopos

    1996-12-31

    Onion bulbs of the Valenciana Sintetica 14 variety from Argentina were irradiated with a dose of 60 Gy gamma rays at 30-40 days after harvest. Treated and control lots (40 bags of 20 Kg each) were send by road to Piracicaba, SP, Brazil, and stored up to 180 days in a warehouse at 20-28{sup 0} C and relative humidity ranging from 50 to 100%. Monthly quality control was done by physical and sensorial analysis. Radiation treatment reduced the weight loss of the bulbs and increased the percentage of marketable bulbs without affecting its sensorial properties. (author). 4 refs, 8 tabs.

  7. Ribeira do Iguape basin water quality assessment for drinking water supply; Avaliacao da qualidade da agua na bacia hidrografica do Ribeira de Iguape com vistas ao abastecimento publico

    Energy Technology Data Exchange (ETDEWEB)

    Cotrim, Marycel Elena Barboza

    2006-07-01

    Ribeira do Iguape Basin, located in the Southeast region of Sao Paulo state, is the largest remaining area of Mata Atlantica which biodiversity as rich as Amazon forest , where the readiness of water versus demand is extremely positive. With sparse population density and economy almost dependent on banana agriculture, the region is still well preserved. To water supply SABESP (Sao Paulo State Basic Sanitation Company). Ribeira do Iguape Businesses Unit - RR, uses different types of water supplies. In the present work, in order to ascertain water quality for human consumption, major and minor elements were evaluated in various types of water supply (surface and groundwater's as well as the drinking water supplied). Forty three producing systems were monitored: 18 points of surface waters and treated distributed water, 10 points of groundwater and 15 points of surface water in preserved areas, analyzing 30 elements. Bottom sediments (fraction < 63 {mu}m) were also evaluated. The sampling period covered dry and wet seasons from March 2002 to February 2003. The descriptive analysis showed that Al, Fe and Mn, exceeding CONAMA 357 quality guideline. A comparison of the elemental concentrations with the Brazilian Drinking Water Legislation (Portaria 518/04) showed that with the exception of some violations, the levels of all the elements investigated were below the Brazilian Legislation maximum allowed concentrations. This study examined the relationship between the type of water supply and the quality of water used, showed different characteristics on Ca, Fe, Mn concentration. In bottom sediments (fraction <63 {mu}m), Al, Fe and Mg largest concentrations were found. Pb and Zn presents concentrations up to 142,0 {mu}g.g{sup -1} and 172 {mu}g.g{sup -1}, respectively. Data revealed that trace elements concentration in the sediment were below PEL (Probable Effect Level - probable level of adverse effect to the biological community), exception for Pb in Sete Barras and Eldorado. (author)

  8. Assessing the quality of energy supplied by small renewable energy systems; Avaliacao da qualidade da energia fornecida por sistemas renovaveis isolados de pequeno porte

    Energy Technology Data Exchange (ETDEWEB)

    Galhardo, Marcos Andre Barros; Pinho, Joao Tavares [Universidade Federal do Para (UFPA), Belem, PA (Brazil). Grupo de Estudos e Desenvolvimento de Alternativas Energeticas], e-mail: galhardo@ufpa.br, E-mail: jtpinho@ufpa.br

    2004-07-01

    This paper makes an analysis of the power quality supplied by small renewable energy systems with energy storage in a battery bank and its DC/AC conversion by an inverter. It is shown that the power quality supplied by stand-alone renewable systems depends on the used inverter, specially of its voltage waveform, the load supplied and the voltage level in the battery bank, which has a direct influence on the value of the rms output voltage of the inverter. For these analysis, measurements are presented for typical loads used in these systems as illumination, TV, refrigerator, etc., and combinations of these loads, supplied by different waveforms. (author)

  9. Study and evaluation of radiometry in photo therapeutic treatment of the neonatal hyperbilirubinaemia; Estudo e avaliacao da radiometria no tratamento fototerapico da hiperbilirrubinemia neonatal

    Energy Technology Data Exchange (ETDEWEB)

    Caly, Jose Pucci

    2009-07-01

    Phototherapy is a procedure established more than 50 years ago in the treatment of the newborn jaundice. However there is no a standard method to quantify the photo therapeutic dose in published clinical studies, hindering the comparison of previous studies on photo therapeutic effectiveness, as well as the establishment of safe and predictable doses. The photo therapeutic dose depends, among other factors, on the effective mean irradiance produced by the photo therapeutic unit. There are no standard procedures, however, neither to quantify the effective irradiance, nor to estimate the mean effective irradiance. As a consequence, large measurement variations in a same photo therapeutic unit are observed using different commercially available radiometers, as a consequence of the vast diversity of spectral responsivities of the instruments. An objective of this work was to adapt and to apply the bases of the wideband ultraviolet radiometry to quantify the available irradiance from photo therapeutic units, establishing procedures that allow us to compare measured irradiances from different sources, using radiometers presenting different spectral responsivities. Another objective was to characterize samples of photo therapeutic units commonly used, focusing the problem of the estimation of the effective mean irradiance from photo therapeutic units, proposing a method to estimate of the effective irradiance from focused sources. The experimental results allow us to conclude that it is not only necessary to standardize the photo therapeutic radiometry, but also the method of estimation of the effective mean irradiance. (author)

  10. Evaluation of X ray attenuation by means of radiographic images; Avaliacao da atenuacao da radiacao X por meio de imagens radiograficas

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Frieda Saicla, E-mail: saicla@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Paredes, Ramon S.C., E-mail: ramon@ufpr.b [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil); Godoi, Walmor C., E-mail: walmor.godoi@gmail.co [Faculdade de Tecnologia Camoes (FATEC), Curitiba, PR (Brazil); Souza, Gabriel Pinto de [Universidade Estadual Paulista (UNESP), SP (Brazil)

    2011-07-01

    This paper's main goal is to adopt a qualitative methodology to evaluate the attenuation of x-radiation through X-ray images in polymeric materials plus residual lead. To determinate the images it was initially used an experimental setup at the Laboratory for Materials Diagnostics LACTEC. These results correspond to a more qualitative analysis, even with quantitative answers. Through analysis of radiographic images we can measure the intensity of radiation that goes through the plate, making possible to establish a relationship between the attenuation coefficient and the thickness of the material. (author)

  11. Evaluation of the morphological alteration of the root surface radiated with a diode laser; Avaliacao da alteracao morfologica da superficie cimentaria irradiada com laser de diodo

    Energy Technology Data Exchange (ETDEWEB)

    Gulin, Mauricio

    2003-07-01

    The diode laser has been studied for periodontal therapy, as much for removal of calculus as for microbial reduction of periodontal pockets, as well as the visible analgesic effects and biomodulation capacity. For this reason the purpose of this study was to evaluate the morphological alteration of the root surface after radiation with the diode laser, 808 nm through analysis by scanning electron microscopy (SEM). Besides this, to verify the temperature variations caused during the radiation, a thermometer put into the dentinal wall of the root canal was used. In all, 18 teeth were used, 15 of which for the SEM study, and the other 3 were used to temperature variation analysis. The 25 samples were scraped on the root surface and planed with manual instruments. The other 5 were not subjected to any type of treatment. This, 6 groups of 5 samples each were formed. Control Group C whose samples had not received any treatment; Control Group C 1 was only scraped and polished conventionally with Hu-Friedy Gracey curettes 5 and 6; the other samples groups L1, L2, L3, L4 were radiated by diode laser using parameters of power 1,0 W; 1,2 W; 1,4 W; and 1,6 W respectively, 2 times for 10 seconds with 20 seconds intervals between each radiation in continuous mode. The results with relation to the increase of temperature in the interior of the root canal demonstrated that there was an increase of more than 5 degree Celsius. The results of the scanning electron microscope analysis of Control Group C demonstrated great irregularity and ridges on the root surface, with the presence of a dentine layer. Control Group C1 presented a similar aspect to Group L 1's, smoother and more homogeneous surface. Groups L2, L3, and L4 presented scratches alternating with smoother areas showing that fiber contacted the surface of the sample. The results reconfirmed the necessity of further studies using diode laser, with a beam of light emitted in an interrupted mode to improve the control of the increase of temperature during radiation, and probably followed by a new scraping and root polishing with conventional instruments in an attempt to obtain a smoother and more homogeneous root surface. (author)

  12. Technique applied in the evaluation of the UFCC reactor at Refinaria Alberto Pasqualini (REFAP), PETROBRAS; Tecnicas utilizadas na avaliacao do reator da UFCC da REFAP

    Energy Technology Data Exchange (ETDEWEB)

    Cascaes, Ronesio da Silva [PETROBRAS (Brazil) Refinaria Alberto Pasqualini

    1994-01-01

    Main problems found in the maintenance of the Fluidized Catalytic Cracking (FCC) unity, searches of metal alteration properties, metallographic evaluations, failures and micro-structures alterations are presented. Micrographic analysis of the structural samples, the methodology to detect the failures and physical and chemical essays utilized in the inspection are also reported 13 refs., 64 figs., 1 tab.

  13. Evaluation of testosterone serum levels in testicular interstitial fluid under thyroxine influence; Avaliacao da testosterona no fluido intersticial testicular sob influencia da tiroxina

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Isvania Maria S. da; Pereira, Simey de L.S.; Souza, Grace Mary L.; Carvalho, Elaine F.M.B.; Catanho, Maria Teresa J. de A. [Pernambuco Univ., Recife, PE (Brazil). Dept. de Biofisica e Radiobiologia; Silveira, Maria de Fatima G. da [Pernambuco Univ., Recife, PE (Brazil). Dept. de Anatomia; Lima Filho, Guilherme L. [Universidade de Pernambuco (UPE), Nazare da Mata, PE (Brazil). Faculdade de Formacao de Professores

    2000-07-01

    The thyroid hormones possibly exert a reciprocal action between testicular steroids and Sertoli's cells during the premature period. This work aims to evaluate thyroxine effect on testosterone serum levels and in the testicular interstitial fluid (TIF) in rats. Wistar males rats, 22 days old, 80g of body weight, were induced to hyperthyroidism with thyroxine (20{mu}g/kg) in periods of 5, 10, 15 and 20 consecutive days. After the treatment the animals were weighed and sacrificed for blood and testis collection. From the blood serum and from the TIF drained from the testis were performed testes in order to obtain testosterone attached to {sup 125} I with a specific activity of 36,86 MBq/ig. The results have shown a testosterone significant lineal increase in both - serum and TIF - in the group treated with thyroxine as a time function. In the control group, testosterone levels remained low in both serum and TIF dosages. As a result, we were able to verify that the testosterone levels could be modified by thyroxine in serum and TIF. And so, it could affect luteinizing hormone (LH) and follicle-stimulating hormone (FSH) levels in hypophysis. (author)

  14. Quality assessment of radiopharmaceuticals in nuclear medicine services at Northeast states, Brazil; Avaliacao da qualidade de radiofarmacos em servicos de medicina nuclear de estados da regiao nordeste

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Wellington Gomes de

    2012-07-01

    The radiopharmaceuticals are used in the field nuclear medicine services (NMS) as tracer in the diagnoses and treatment of many diseases. Radiopharmaceuticals used in nuclear medicine and usually have a minimum of pharmacological effect. The procedures for labelling Radiopharmaceuticals should be observed in order to minimize risks to patients, employees and individuals from the public, and to be administered in humans, must be sterile and free of pyrogens and possess elements all measures of quality controls required a conventional drug. The 'Agencia Nacional de Vigilancia Sanitaria (ANVISA)' in its 'Resolucao de Diretoria Colegiada' (RDC) No. 38 of June 4{sup th} 2008, decided that the NMS must perform quality control in the generators eluate and radiopharmaceuticals according to recommendations of manufacturers and scientific evidence accepted by ANVISA. Thus, this study proposes to evaluate the quality of the generator {sup 99M}o-{sup 99m}Tc eluate and radiopharmaceuticals labeled with {sup 99m}Tc used in most NMS of some states in the Northeast, in relation to radionuclide, chemical, radiochemical purity and pH and promote the inclusion of procedure for quality control of radiopharmaceuticals in routine NMS. The results show that 90% radionuclidic purity, 98.2% purity chemical and radiochemical purity of 46% and 100% of the eluates are in agreement with international pharmacopoeias; already radiopharmaceuticals showed 82.6% purity and all radiochemical pH values are also in accordance with international pharmacopoeias. Even with so many positive results, staff the majority of MNS was not able to perform the quality control of the eluates and radiopharmaceuticals. Showing the importance of implementing of quality control programs of the eluates and radiopharmaceuticals in nuclear medicine. (author)

  15. Synthesis and evaluation of phytotoxic activity of {alpha}-Santonin derivatives; Sintese e avaliacao da atividade fitotoxica de derivados da {alpha}-Santonina

    Energy Technology Data Exchange (ETDEWEB)

    Alvarenga, Elson S.; Barbosa, Luiz C.A.; Saliba, William A.; Arantes, Francisco F.P.; Demuner, Antonio J. [Universidade Federal de Vicosa (UFV), MG (Brazil). Dept. de Quimica]. E-mail: elson@ufv.br; Silva, Antonio A. [Universidade Federal de Vicosa (UFV), MG (Brazil). Dept. de Fitotecnia

    2009-07-01

    Mixtures of {alpha}-Santonin and various solvents were irradiated by either high or low pressure mercury lamps. The photochemical reactions afforded lumisantonin (11) (76% in acetonitrile), (3 S,3a S,9{beta}S)-3,6,6-trimethyl-3,3a,4,5-tetrahydronafto[1,2-b]furan-2,7({eta}6,9{beta}{eta}) dione (12) (100% in acetonitrile), 10{alpha}-acetoxy-3-oxo-1,7{alpha}H{eta},6,11{alpha}a{eta}-guaia-4-en-6,12-oli= de (8) (26% in acetic acid), 10{alpha}-hydroxy-3-oxo-1,7{alpha}a{eta},6,11{alpha}{eta}-guaia-4-en-6,12-olid= e (10) (32%) and (E)-3-((3 S,3a S,7{alpha}S)-3-methyl-2-oxo-6-(propan-2-ylidene)hexahydrobenzofuran- 7 - (7{alpha}{eta})-ylidene)propanoic acid (9) (44%) (in water/ acetic acid 1:1, v/v). Lactone 12 was also prepared by irradiation of lumisantonin in diethyl ether. Lactones 8 and 10 were converted, respectively, into the 10 {alpha}-acetoxy-3{alpha}-hydroxy-1,7{alpha}H,6,11{alpha}H-guaia-4-en-6,12-olid= e (13) (87%) and 3a,10a-dihydroxy-1,7{alpha}H,6,11{alpha}H-guaia-4-en-6,12-olide (14) (75%) by sodium borohydride reduction. The effects of the compounds on the development of radicle of Sorghum bicolor and Cucumis sativus were evaluated. (author)

  16. Development of test objects for image quality evaluation of digital mammography; Desenvolvimento de objetos de teste para avaliacao da qualidade da imagem em mamografia digital

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Vitor Nascimento de Carvalho

    2013-07-01

    Mammography is the image exam called 'gold standard' for early detection of breast cancer. 111 Brazil, more than eight million mammograms are carried out per year. With the advancement of technology, the digital systems CR and DR for this diagnostic modality have been increasingly implemented, replacing the conventional screen-film system, which brought environmental problems, like the disposal of chemical waste, and is also responsible for the rejection of radiographic films with processing artifacts. Digital systems, besides not experiencing the problem of environmental pollution, are still capable of image processing, allowing a much lower rejection rate when compared to the conventional system. Moreover, the determination of an accurate diagnosis is highly dependent on the image quality of the examination. To ensure the reliability of the images produced by these systems, it is necessary to evaluate them on a regular basis. Unfortunately, there is no regulation in Brazil about the Quality Assurance of these systems. The aim of this study was to develop a set of test objects that allow the evaluation of some parameters of image quality of these systems, such as field image uniformity, the linearity between the air Kerma incident on detector and the mean pixel value (MPV) of the image, the spatial resolution of the system through the modulation transfer function (MTF) and also to suggest an object to be applied in the evaluation of contrast-to-noise ratio (CNR) and signal-difference-to-noise ratio (SDNR). In order to test the objects. 10 mammography centers were evaluated, seven with CR systems and three with the DR systems. To evaluate the linearity, besides the test objects high sensitivity dosimeters were necessary to be used, namely LiF:Mg,Cu,P TL dosimeters. The use of these dosimeters was recommended in order to minimize the time required to perform the tests and to decrease the number of exposures needed. For evaluation of digital images in DICOM format, the software {sup O}BJ{sub I}QJeduced{sup ,} version 3.0, was used. It was developed by the team of Prof.. Dr. Nicholas Marshall at the Catholic University of Leuven, Belgium. The results were very promising, leaving opened the possibility of future work as the optimization of the correction factors and uncertainties for the dosimeters as well as the applicability of the test objects in evaluating the image quality of digital systems across the country. (author)

  17. Use of different simulators to quality evaluation of image quality in digital mammography; Utilizacao de diferentes simuladores na avaliacao da qualidade da imagem em mamografia digital

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Leslie S.; Coutinho, Celia M.C., E-mail: leslie@ird.gov.br, E-mail: celia@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Magalhaes, Luis A.G.; Almeida, Carlos Eduardo de, E-mail: luisalexandregm@hotmail.com, E-mail: cea71@yahoo.com.br [Universidade do Estado do Rio de Janeiro (LCR/UERJ), Rio de Janeiro, RJ (Brazil). Laboratorio de Ciencias Radiologicas

    2013-11-01

    In this study, the digital images were acquired with different exposure simulators to evaluate the quality of the image, noting the tumor mass detection, microcalcification fiber and representing regions of interest during mammography. The technical parameters of exposure depends on the thickness and composition of the breast, thus affecting the dose and image quality. The simulators were used: ACR, SBP 1054, BREAST PHANTOM CIRS and for evaluation of image quality, as well as measures kerma incident on the entrance surface (Ki) and calculating the mean glandular dose (MGD)

  18. Evaluation of the morphological alteration of the root surface radiated with a diode laser; Avaliacao da alteracao morfologica da superficie cimentaria irradiada com laser de diodo

    Energy Technology Data Exchange (ETDEWEB)

    Gulin, Mauricio

    2003-07-01

    The diode laser has been studied for periodontal therapy, as much for removal of calculus as for microbial reduction of periodontal pockets, as well as the visible analgesic effects and biomodulation capacity. For this reason the purpose of this study was to evaluate the morphological alteration of the root surface after radiation with the diode laser, 808 nm through analysis by scanning electron microscopy (SEM). Besides this, to verify the temperature variations caused during the radiation, a thermometer put into the dentinal wall of the root canal was used. In all, 18 teeth were used, 15 of which for the SEM study, and the other 3 were used to temperature variation analysis. The 25 samples were scraped on the root surface and planed with manual instruments. The other 5 were not subjected to any type of treatment. This, 6 groups of 5 samples each were formed. Control Group C whose samples had not received any treatment; Control Group C 1 was only scraped and polished conventionally with Hu-Friedy Gracey curettes 5 and 6; the other samples groups L1, L2, L3, L4 were radiated by diode laser using parameters of power 1,0 W; 1,2 W; 1,4 W; and 1,6 W respectively, 2 times for 10 seconds with 20 seconds intervals between each radiation in continuous mode. The results with relation to the increase of temperature in the interior of the root canal demonstrated that there was an increase of more than 5 degree Celsius. The results of the scanning electron microscope analysis of Control Group C demonstrated great irregularity and ridges on the root surface, with the presence of a dentine layer. Control Group C1 presented a similar aspect to Group L 1's, smoother and more homogeneous surface. Groups L2, L3, and L4 presented scratches alternating with smoother areas showing that fiber contacted the surface of the sample. The results reconfirmed the necessity of further studies using diode laser, with a beam of light emitted in an interrupted mode to improve the control of the increase of temperature during radiation, and probably followed by a new scraping and root polishing with conventional instruments in an attempt to obtain a smoother and more homogeneous root surface. (author)

  19. Evaluation of the introduction of cogeneration for refrigeration in the fisheries sector of the Amazon; Avaliacao da introducao da cogeracao para refrigeracao no setor pesqueiro do Amazonas

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, Ricardo Wilson Aguiar da [Universidade Estadual do Amazonas (UEA), Manaus (Brazil)], e-mail: rcruz@uea.edu.br; Nebra, Silvia Azucena [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Faculdade de Engenharia Mecanica], e-mail: sanebra@fem.unicamp.br; Cartaxo, Elizabeth Ferreira [Universidade Federal do Amazonas (UFAM), Manaus, AM (Brazil)], e-mail: ecartaxo@ufam.edu.br

    2004-07-01

    This work analyses the opportunity to introduce cogeneration for the production of aquammonia absorption refrigeration in the autonomous Amazons State power system, by one hand as a means to improve its efficiency and by another, solve the deficiency the State has to store its fish-ing production. (author)

  20. Evaluation of gels obtained from acetylation of chitosan in heterogeneous medium; Avaliacao de geis obtidos a partir da acetilacao da quitosana em meio heterogeneo

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, Rosangela Balaban; Silva, Dayse Luzia Pinheiro da; Costa, Marta [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Dept. de Quimica]. E-mail: balaban@digi.com.br; Raffin, Fernanda Nervo [Universidade Federal do Rio Grande do Norte (UFRGN), Natal, RN (Brazil). Centro de Ciencias da Saude. Dept. de Quimica, Tecnologia Farmaceutica e de Alimentos; Ruiz, Naira Machado da Silva [Centro de Pesquisa Leopoldo A. Miguez de Mello (CENPES), Rio de Janeiro, RJ (Brazil)

    2008-07-01

    Chitosan was acetylated during 2, 5 and 10 h and physical gels were obtained at different polymer concentrations in N,N-dimethylacetamide containing 5% of LiCl. Acetylation was confirmed by infrared spectroscopy and {sup 13}C NMR, and degrees of acetylation in the range of 0.82-0.91 were determined by NMR. The O-acetylation degree (0.12-0.15) was exclusively determined by a volumetric method. Rheological studies showed that the storage modulus values were smaller for the more acetylated samples and increased with the temperature and the polymer concentration. All the gels presented storage modulus superior to loss modulus, evidencing more elastic than viscous characteristics. The results obtained in this work suggest a gelation process based on a balance between O and N-acetylation and intermolecular bonds. (author)

  1. Quality assessment of radiopharmaceuticals in nuclear medicine services at Northeast states, Brazil; Avaliacao da qualidade de radiofarmacos em servicos de medicina nuclear de estados da regiao nordeste

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Wellington Gomes de

    2012-07-01

    The radiopharmaceuticals are used in the field nuclear medicine services (NMS) as tracer in the diagnoses and treatment of many diseases. Radiopharmaceuticals used in nuclear medicine and usually have a minimum of pharmacological effect. The procedures for labelling Radiopharmaceuticals should be observed in order to minimize risks to patients, employees and individuals from the public, and to be administered in humans, must be sterile and free of pyrogens and possess elements all measures of quality controls required a conventional drug. The 'Agencia Nacional de Vigilancia Sanitaria (ANVISA)' in its 'Resolucao de Diretoria Colegiada' (RDC) No. 38 of June 4{sup th} 2008, decided that the NMS must perform quality control in the generators eluate and radiopharmaceuticals according to recommendations of manufacturers and scientific evidence accepted by ANVISA. Thus, this study proposes to evaluate the quality of the generator {sup 99M}o-{sup 99m}Tc eluate and radiopharmaceuticals labeled with {sup 99m}Tc used in most NMS of some states in the Northeast, in relation to radionuclide, chemical, radiochemical purity and pH and promote the inclusion of procedure for quality control of radiopharmaceuticals in routine NMS. The results show that 90% radionuclidic purity, 98.2% purity chemical and radiochemical purity of 46% and 100% of the eluates are in agreement with international pharmacopoeias; already radiopharmaceuticals showed 82.6% purity and all radiochemical pH values are also in accordance with international pharmacopoeias. Even with so many positive results, staff the majority of MNS was not able to perform the quality control of the eluates and radiopharmaceuticals. Showing the importance of implementing of quality control programs of the eluates and radiopharmaceuticals in nuclear medicine. (author)

  2. Ribeira do Iguape basin water quality assessment for drinking water supply; Avaliacao da qualidade da agua na bacia hidrografica do Ribeira de Iguape com vistas ao abastecimento publico

    Energy Technology Data Exchange (ETDEWEB)

    Cotrim, Marycel Elena Barboza

    2006-07-01

    Ribeira do Iguape Basin, located in the Southeast region of Sao Paulo state, is the largest remaining area of Mata Atlantica which biodiversity as rich as Amazon forest , where the readiness of water versus demand is extremely positive. With sparse population density and economy almost dependent on banana agriculture, the region is still well preserved. To water supply SABESP (Sao Paulo State Basic Sanitation Company). Ribeira do Iguape Businesses Unit - RR, uses different types of water supplies. In the present work, in order to ascertain water quality for human consumption, major and minor elements were evaluated in various types of water supply (surface and groundwater's as well as the drinking water supplied). Forty three producing systems were monitored: 18 points of surface waters and treated distributed water, 10 points of groundwater and 15 points of surface water in preserved areas, analyzing 30 elements. Bottom sediments (fraction < 63 {mu}m) were also evaluated. The sampling period covered dry and wet seasons from March 2002 to February 2003. The descriptive analysis showed that Al, Fe and Mn, exceeding CONAMA 357 quality guideline. A comparison of the elemental concentrations with the Brazilian Drinking Water Legislation (Portaria 518/04) showed that with the exception of some violations, the levels of all the elements investigated were below the Brazilian Legislation maximum allowed concentrations. This study examined the relationship between the type of water supply and the quality of water used, showed different characteristics on Ca, Fe, Mn concentration. In bottom sediments (fraction <63 {mu}m), Al, Fe and Mg largest concentrations were found. Pb and Zn presents concentrations up to 142,0 {mu}g.g{sup -1} and 172 {mu}g.g{sup -1}, respectively. Data revealed that trace elements concentration in the sediment were below PEL (Probable Effect Level - probable level of adverse effect to the biological community), exception for Pb in Sete Barras and Eldorado. (author)

  3. Reprodutibilidade das mensurações da espessura das tábuas ósseas na tomografia computadorizada Cone-Beam utilizando diferentes protocolos de aquisição de imagem Reproducibility of bone plate thickness measurements with Cone-Beam Computed Tomography using different image acquisition protocols

    Directory of Open Access Journals (Sweden)

    Carolina Carmo de Menezes

    2010-10-01

    Full Text Available INTRODUÇÃO: quanto menor a dimensão do voxel, maior a nitidez da imagem de tomografia computadorizada Cone-Beam (TCCB, porém, maior a dose de radiação emitida. OBJETIVOS: avaliar e comparar a reprodutibilidade da mensuração da espessura das tábuas ósseas vestibular e lingual em imagens de TCCB, utilizando diferentes protocolos de aquisição de imagem com variação da dimensão do voxel. MÉTODOS: exames de TCCB foram tomados de 12 mandíbulas humanas secas, com dimensão do voxel de 0,2; 0,3 e 0,4mm, no aparelho i-CAT Cone-Beam 3-D Dental Imaging System. No software i-CAT Viewer, foi mensurada a espessura das tábuas ósseas vestibular e lingual, em um corte axial passando 12mm acima do forame mentoniano do lado direito. A reprodutibilidade intraexaminador foi avaliada por meio da aplicação do teste t pareado. Para a comparação interexaminadores, foi utilizado o teste t independente. Os resultados foram considerados com o nível de significância de 5%. RESULTADOS: observou-se uma excelente reprodutibilidade interexaminadores para os três protocolos avaliados. A reprodutibilidade intraexaminadores foi muito boa, com exceção de algumas regiões dos dentes anteriores, que mostraram diferenças estatisticamente significativas, independentemente da dimensão do voxel. CONCLUSÃO: a mensuração da espessura das tábuas ósseas vestibular e lingual em imagens de TCCB mostrou boa precisão para exames obtidos com voxel de 0,2; 0,3 ou 0,4mm. A reprodutibilidade das mensurações na região anterior da mandíbula foi mais crítica do que na região posterior.INTRODUCTION: A smaller voxel dimension leads to greater resolution of Cone-Beam Computed Tomography (CBCT, but a greater dosage of radiation is emitted. OBJECTIVE: Assess and compare the reproducibility of buccal and lingual bone plate thickness measurements in CBCT images using different image acquisition protocols, with variations in the voxel dimension. METHODS: CBCT exams

  4. The diagnostic contribution of computed tomography in intranasal carcinoma with retrobulbar, oral and brain invasion in a canine: case report; Contribuicao da tomografia computadorizada no diagnostico de carcinoma intranasal com invasao retrobular, oral e cerebral em canino: relato de caso

    Energy Technology Data Exchange (ETDEWEB)

    Zardo, Karen Maciel, E-mail: kmz@bol.com.br; Belotta, Alexandra Frey; Babicsak, Viviam Rocco; Machado, Vania Maria de Vasconcelos [Universidade Estadual Paulista Julio de Mesquita Filho (FMVZ/UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Reproducao Animal e Radiologia Veterinaria; Zanoni, Diogo Souza; Costa, Denis Carvalho [Universidade Estadual Paulista Julio de Mesquita Filho (FMVZ/UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Clinica Veterinaria

    2012-07-01

    Intranasal tumors are uncommon and in most cases are malignant, aggressive and with low to moderate potential for metastasis. Clinical signs are usually caused by progressive obstruction of the upper airways. The test cytopathological also is a diagnosis method, but the definitive diagnosis is made by histopathological. Computed tomography (CT) is recommended to treatment planning. A poodle was attended at the veterinary hospital with a clinical history of epistaxis and nasal and ocular secretions, seizures and severe dyspnoea. The animal underwent to radiographic examination of the chest and skull as well as helical computed tomography of the nasal cavity and brain before and after the administration of intravenous contrast. The CT findings revealed an expansive bilateral nasal cavity neoformation, with involvement of the retrobulbar space, right frontal sinus, brain and oral cavity, suggesting a neoplastic or an infectious process. The CT examination allowed the material collection, directly from the mass, to cytological examination, providing the diagnosis of carcinoma. CT also allowed the determination of the unfavorable prognosis of the patient and the treatment planning which not included the surgical excision of the neoformation. Although CT was not conclusive in the diagnosis of carcinoma, it was essential to accurately define the extent of the lesion, to guide the collection of material directly from the tumor and to determine the prognosis of the animal, proving to be an extremely useful tool in cases of tumors intranasal in dogs. (author)

  5. Ground-glass opacity in diffuse lung diseases: high-resolution computed tomography-pathology correlation; Opacidades em vidro fosco nas doencas pulmonares difusas: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Maria Lucia de Oliveira; Vianna, Alberto Domingues; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Disciplina de Radiologia; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Patologia]. E-mail: edmarchiori@zipmail.com.br

    2003-12-01

    Ground-glass opacity is a finding frequently seen in high-resolution computed tomography examinations of the chest and is characterized by hazy increased attenuation of lung, however without blurring of bronchial and vascular margins. Due to its un specificity, association with other radiological, clinical and pathological findings must be considered for an accurate diagnostic interpretation. In this paper were reviewed 62 computed tomography examinations of patients with diffuse pulmonary diseases of 14 different etiologies in which ground-glass opacity was the only or the most remarkable finding, and correlated this findings with pathology abnormalities seen on specimens obtained from biopsies or necropsies. In pneumocystosis, ground-glass opacities correlated histologically with alveolar occupation by a foaming material containing parasites, in bronchiole alveolar cell carcinoma with thickening of the alveolar septa and occupation of the lumen by mucus and tumoral cells, in paracoccidioidomycosis with thickening of the alveolar septa, areas of fibrosis and alveolar bronchopneumonia exudate, in sarcoidosis with fibrosis or clustering of granulomas and in idiopathic pulmonary fibrosis with alveolar septa thickening due to fibrosis. Alveolar occupation by blood was found in cases of leptospirosis, idiopathic hemo siderosis, metastatic kidney tumor and invasive aspergillosis whereas oily vacuole were seen in lipoid pneumonia, proteinaceous and lipo proteinaceous material in silico proteinosis and pulmonary alveolar proteinosis, and edematous fluid in cardiac failure. (author)

  6. Calcificação nos núcleos da base na tomografia computadorizada: correlação clínica em 25 pacientes consecutivos Basal ganglia calcification on computed tomography: clinical characteristics in 25 patients

    Directory of Open Access Journals (Sweden)

    Glória Maria A.S. Tedrus

    2006-03-01

    Full Text Available Analisamos os aspectos clínicos de 25 pacientes consecutivos que apresentaram calcificação nos núcleos da base na tomografia computadorizada (TC de crânio. Esta ocorreu em 0,68% de todos os exames realizados no período. Vinte e três pacientes apresentavam condições clínicas diversas, a saber: cefaléia em 7 casos, acidente vascular cerebral em 5, síndrome extrapiramidal em 2, processo expansivo cerebral em 2, epilepsia, retardo do desenvolvimento neuropsicomotor, demência e trauma de crânio em um caso cada ou outras condições neurológicas em 3. Não havia sintomas neurológicos em 2 casos. Em 15 pacientes (60,0% havia, além da calcificação dos núcleos da base, outras alterações na TC. Correlação clínica foi observada apenas com as outras alterações da TC e não com a calcificação dos núcleos da base, corroborando a hipótese de que esta possa ser um achado incidental.Twenty-five patients presenting basal ganglia calcification were assessed. This finding comprised 0.68% of all skull CT scan carried out during the period. Two patients were neurologically asymptomatic and 23 presented a variety neurological disorders - headache (7 patients, stroke (5 patients, extrapyramidal syndromes (2 patients, tumor (2 patients, epilepsy (1 patient, mental retardation (1 patient, dementia (1 patient, cranial trauma (1 patient, other neurological conditions (3 patients - or were asymptomatic from the neurological point of view (2 patients. Findings in the CT scan other than the basal ganglia calcification were observed in 15 (60% patients. There was a clinical-CT scan correlation in these cases but not in those in which the basal ganglia calcification was an isolated finding. This study highlights the fact that basal ganglia calcification is often a nonspecific finding on CT scan and that it may not be possible to establish a clinical-pathological correlation between them.

  7. Avaliando a difusão de tecnologias médicas no sistema de saúde privado no Brasil: o caso da tomografia por emissão de pósitrons (PET Assessing the use of medical technology in the private health system in Brazil: the case of Positron Emission Tomography (PET

    Directory of Open Access Journals (Sweden)

    Ana Luiza d´Ávila Viana

    2010-11-01

    Full Text Available OBJETIVOS: analisar os determinantes da difusão da tomografia por emissão de pósitrons (PET em um conjunto selecionado de prestadores de serviços e operadoras de planos de saúde no Brasil. MÉTODOS: estudo de caso qualitativo, com coleta de dados realizada por meio de entrevistas em profundidade (N=9 com representantes de quatro prestadores de serviços de saúde privados e três operadoras de planos de saúde. RESULTADOS: as decisões para aquisição da tecnologia estudada são tomadas por dirigentes de hospitais e clínicas que adotam uma estratégia de diferenciação baseada em liderança tecnológica. Os fatores que influenciam essa decisão são: histórico de pioneirismo da instituição na incorporação de tecnologias; pressão do corpo clínico vinculado à instituição; prestígio do médico ou da área demandante; disponibilidade de recursos financeiros; acesso facilitado à tecnologia; concorrência entre os prestadores de serviços de saúde; evidências científicas; e rentabilidade do investimento. CONCLUSÕES: os atuais instrumentos de política usados para gerenciar a difusão de tecnologias médicas no sistema de saúde brasileiro exercem pouca influência nas decisões de grandes prestadores privados, cujas atividades não estão necessariamente relacionadas com as necessidades de saúde da população ou com as prioridades da política de saúde.OBJECTIVES: to analyze the determining factors underlying the extent to which positron emission tomography (PET is used in a selected medical services provider covered by private health insurance plans in Brazil. METHODS: a qualitative case study was undertaken with data collected by means of in-depth interviews (N=9 with representatives of four private health service providers and three health insurance plan operators. RESULTS: the decisions to acquire the technology under study are taken by managers of hospitals and clinics that adopt a strategy based on excellence in

  8. Turbocharging Quantum Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Gamble, John King [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Nielsen, Erik [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Maunz, Peter Lukas Wilhelm [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Scholten, Travis L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Rudinger, Kenneth Michael [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography suffers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. We describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more effectively detect and characterize quantum noise using carefully tailored ensembles of input states.

  9. Severe bronchiectasis in a dog: tomographic evaluation; Severa bronquiectasia em um cao: avaliacao tomografica

    Energy Technology Data Exchange (ETDEWEB)

    Babicsak, Viviam Rocco; Campos, Lidice Araujo; Belotta, Alexandra Frey; Oliveira, Hugo Salvador de; Inamassu, Leticia Rocha; Charlier, Murilo Gomes de Soutello; Mamprim, Maria Jaqueline; Vulcano, Luiz Carlos, E-mail: viviam.babicsak@gmail.com [Universidade Estadual Paulista Julio de Mesquita Filho (FMVZ/UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Reproducao Animal e Radiologia Veterinaria

    2012-07-01

    Bronchiectasis is a bronchial dilatation caused by changes in the bronchial wall usually due to infectious processes. Computed tomography is an important imaging modality for the evaluation of this alteration due to its high sensitivity. In this study we describe the case report of a 6-year-old female mixed breed dog with severe and generalized bronchiectasis on computed tomography. Due to the severe extent of bronchiectasis, the method of measurement of the adjacent pulmonary artery and its relationship to the bronchus did not have to be performed. An indirect sign of bronchiectasis identified in the patient was the bronchial wall thickening, possibly due to the infiltration of inflammatory components, edema and even by peri-bronchial abscesses. (author)

  10. Auxílio da tomografia computadorizada no planejamento pré-operatório de pacientes portadores de escoliose idiopática do adolescente Auxilio de la tomografía computarizada en el plan preoperatorio de pacientes portadores de escoliosis idiopática del adolescente Computed tomography aid in preoperative planning of patients with adolescent idiopathic scoliosis

    Directory of Open Access Journals (Sweden)

    Rodrigo Rezende

    2010-03-01

    Full Text Available A escoliose idiopática do adolescente (EIA é uma doença diagnosticada no início da puberdade. Ela apresenta etiologia indefinida e caracteriza-se pelo desvio lateral da coluna vertebral maior que 10°, associado à rotação do corpo vertebral. O uso de instrumentação de terceira geração produziu um melhor resultado na correção da curva do que as técnicas anteriores. Porém, ainda existem dificuldades técnicas no momento da passagem e da escolha dos parafusos pediculares, devido à angulação e ao diâmetro dos pedículos vertebrais. Apesar de apresentar vantagens, essa técnica não é isenta de riscos e complicações, necessitando de uma maior curva de aprendizado pelo médico-cirurgião, bem como de um adequado planejamento pré-operatório. Até o momento, não há na literatura relato sobre a utilização da tomografia computadorizada no auxílio do planejamento cirúrgico de pacientes com escoliose. Diante do exposto, objetivamos, no presente estudo, descrever uma técnica de planejamento pré-operatório, com o auxílio da tomografia computadorizada para a fixação da coluna em pacientes com escoliose idiopática do adolescente, especificando a angulação e o diâmetro dos pedículos vertebrais, o que poderá auxiliar o médico-cirurgião no momento da fixação.La escoliosis idiopática en el adolescente (EIA es una enfermedad diagnosticada en el inicio de la pubertad. Esta presenta una etiología indefinida y es caracterizada por el desvío lateral de la columna vertebral por encima de los diez grados asociados a la rotación del cuerpo vertebral. El uso de instrumentación de tercera generación produjo un mejor resultado en la corrección de la curva comparado con las técnicas anteriores. Sin embargo, existen dificultades técnicas en el momento del paso y de escoger los tornillos pediculares debido a la angulación y al diámetro de los pedículos vertebrales. A pesar de presentar ventajas, esta técnica no est

  11. Densitometria da vértebra dorsal, osso pleural e osso neural em tartarugas verdes hígidas por tomografia computadorizada quantitativa Densitometry of dorsal vertebrae, pleural bone and neural bone in healthy green sea turtles by quantitative computed tomography

    Directory of Open Access Journals (Sweden)

    Jannine Forattini de Oliveira

    2012-08-01

    Full Text Available A tomografia computadorizada quantitativa (TCQ é uma técnica com alta sensibilidade, aplicabilidade e precisão no diagnóstico de perda de massa óssea, entretanto a falta de valores de normalidade para animais silvestres limita a sua aplicação clínica. O presente estudo objetiva estabelecer valores médios de radiodensidade do osso trabecular das vértebras dorsais, osso pleural e osso neural de tartarugas marinhas juvenis hígidas utilizando a TCQ. Para isso, utilizou-se um grupo experimental de cinco animais que foram submetidos a exames de tomografia computadorizada helicoidal, sendo as mensurações da radiodensidade óssea realizadas ao nível da terceira, quarta e quinta vértebras dorsais. Os valores médios de radiodensidade do osso trabecular das vértebras dorsais, osso pleural e osso neural foram, respectivamente, de 287,4±39,1, 1093,74±100,4 e 1089,6±86,5 unidades Hounsfield (HU. Estudos complementares devem ser realizados em diferentes espécies e faixas etárias de quelônios para favorecer a aplicação clínica desta técnica.Quantitative computed tomography (QCT is a technique with high sensitivity, applicability and accuracy in the diagnosis of bone loss; however the lack of normal values for wild animals limits their clinical application. This study aims to establish medium values radiodensity trabecular bone of the dorsal vertebrae, bone pleural and neural bone in healthy juvenile sea turtles using the QTC. For this we used an experimental group of five animals that underwent helical computed tomography, and measurements of bone radiodensity conducted at the level of the third, fourth and fifth dorsal vertebrae. The medium values of radiodensity trabecular bone of the dorsal vertebrae, pleural bone, and neural bone were respectively 287.4±39.1, 1093.74±100.4, and 1089.6±86.5 Hounsfield units (HU. Further studies should be performed in different species and ages of turtles to encourage the clinical application of

  12. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  13. Meaning of Interior Tomography

    Science.gov (United States)

    Wang, Ge; Yu, Hengyong

    2013-01-01

    The classic imaging geometry for computed tomography is for collection of un-truncated projections and reconstruction of a global image, with the Fourier transform as the theoretical foundation that is intrinsically non-local. Recently, interior tomography research has led to theoretically exact relationships between localities in the projection and image spaces and practically promising reconstruction algorithms. Initially, interior tomography was developed for x-ray computed tomography. Then, it has been elevated as a general imaging principle. Finally, a novel framework known as “omni-tomography” is being developed for grand fusion of multiple imaging modalities, allowing tomographic synchrony of diversified features. PMID:23912256

  14. Single photon emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-09-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) imaging technique. Content: 1 - Introduction: anatomic, functional and molecular imaging; Principle and role of functional or molecular imaging; 2 - Radiotracers: chemical and physical constraints, main emitters, radioisotopes production, emitters type and imaging techniques; 3 - Single photon emission computed tomography: gamma cameras and their components, gamma camera specifications, planar single photon imaging characteristics, gamma camera and tomography; 4 - Quantification in single photon emission tomography: attenuation, scattering, un-stationary spatial resolution, partial volume effect, movements, others; 5 - Synthesis and conclusion

  15. Borehole radar diffraction tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seong Jun; Kim, Jung Ho; Yi, Myeong Jong; Chung, Seung Hwan; Lee, Hee Il [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1997-12-01

    Tomography is widely used as imaging method for determining subsurface structure. Among the reconstruction algorithms for tomographic imaging, travel time tomography is almost applied to imaging subsurface. But isolated small body comparable with the wavelength could not be well recognized by travel time tomography. Other tomographic method are need to improve the imaging process. In the study of this year, diffraction tomography was investigated. The theory for diffraction tomography is based on the 1st-order Born approximation. Multisource holography, which is similar to Kirchihoff migration, is compared with diffraction tomography. To improve 1st-order Born diffraction tomography, two kinds of filter designed from multisource holography and 2-D green function, respectively, applied on the reconstructed image. The algorithm was tested for the numerical modeling data of which algorithm consists of the analytic computation of radar signal in transmitter and receiver regions and 2-D FDM scheme for the propagation of electromagnetic waves in media. The air-filled cavity model to show a typical diffraction pattern was applied to diffraction tomography imaging, and the result shows accurate location and area of cavity. But the calculated object function is not well matched the real object function, because the air-filled cavity model is not satisfied week scattered inhomogeneity for 1st born approximation, and the error term is included in estimating source wavelet from received signals. In spite of the object function error, the diffraction tomography assist for interpretation of subsurface as if conducted with travel time tomography. And the fracture model was tested, 1st born diffraction tomographic image is poor because of limited view angle coverage and violation of week scatter assumption, but the filtered image resolve the fracture somewhat better. The tested diffraction tomography image confirms effectiveness of filter for enhancing resolution. (author). 14

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  18. Gamma tomography apparatus

    International Nuclear Information System (INIS)

    Span, F.J.

    1988-01-01

    The patent concerns a gamma tomography apparatus for medical diagnosis. The apparatus comprises a gamma scintillation camera head and a suspension system for supporting and positioning the camera head with respect for the patient. Both total body scanning and single photon emission tomography can be carried out with the apparatus. (U.K.)

  19. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  20. Tomography of nonclassical states

    NARCIS (Netherlands)

    Bazrafkan, MR; Man'ko, [No Value

    2003-01-01

    A review of the symplectic tomography method is presented. Superpositions of different types of photon states are considered within the framework of the tomography approach. Such nonclassical photon states as even and odd coherent states, crystallized Schrodinger cat states, and other superposition

  1. Study of ionizing radiation effects in human costal cartilage by thermogravimetry and optical coherence tomography; Estudo dos efeitos da radiacao ionizante em cartilagem costal humana por meio de termogravimetria e tomografia por coerencia optica

    Energy Technology Data Exchange (ETDEWEB)

    Martinho Junior, Antonio Carlos

    2012-07-01

    Tissue Banks around the world have stored human cartilages obtained from post mortem donors for use in several kinds of reconstructive surgeries. To ensure that such tissues are not contaminated, they have been sterilized with ionizing radiation. However, high doses of gamma radiation may cause undesirable changes in the tissues. In this work, we evaluated the possibility of use Optical Coherence Tomography (OCT) and Thermogravimetric Analysis (TGA) to identify possible structural modifications caused by both preservation methods of cartilage and gamma irradiation doses. Cartilages were obtained from cadaveric donors and were frozen at -70 deg C or preserved in glycerol. Irradiation was performed by {sup 60}Co source with doses of 15, 25 and 50 kGy. Our TGA results showed that glycerolized cartilages irradiated with different doses of radiation does not presented statistical differences when compared to the control group for the dehydration rate. However, the same was not observed for deep-frozen cartilages irradiated with 15 kGy. The results of OCT associated to total optical attenuation coefficient showed that doses of 15 kGy promote cross-link between collagen fibrils, corroborating the results obtained from TGA. Moreover, total optical attenuation coefficient values are proportional to stress at break of cartilages, what will be very useful in a near future to predict the quality of the allografts, without unnecessary loss of biological tissue, once OCT is a nondestructive technique. By PS-OCT images, we found that high doses of ionizing radiation does not promote sufficient impairments to promote complete loss of tissue birefringence. Thus, TGA and OCT are techniques that can be used for tissue banks to verify tissue quality before its transplant. (author)

  2. Gamma camera based Positron Emission Tomography: a study of the viability on quantification; Tomografia por emissao de positrons com sistemas PET/SPECT: um estudo da viabilidade de quantifizacao

    Energy Technology Data Exchange (ETDEWEB)

    Pozzo, Lorena

    2005-07-01

    Positron Emission Tomography (PET) is a Nuclear Medicine imaging modality for diagnostic purposes. Pharmaceuticals labeled with positron emitters are used and images which represent the in vivo biochemical process within tissues can be obtained. The positron/electron annihilation photons are detected in coincidence and this information is used for object reconstruction. Presently, there are two types of systems available for this imaging modality: the dedicated systems and those based on gamma camera technology. In this work, we utilized PET/SPECT systems, which also allows for the traditional Nuclear Medicine studies based on single photon emitters. There are inherent difficulties which affect quantification of activity and other indices. They are related to the Poisson nature of radioactivity, to radiation interactions with patient body and detector, noise due to statistical nature of these interactions and to all the detection processes, as well as the patient acquisition protocols. Corrections are described in the literature and not all of them are implemented by the manufacturers: scatter, attenuation, random, decay, dead time, spatial resolution, and others related to the properties of each equipment. The goal of this work was to assess these methods adopted by two manufacturers, as well as the influence of some technical characteristics of PET/SPECT systems on the estimation of SUV. Data from a set of phantoms were collected in 3D mode by one camera and 2D, by the other. We concluded that quantification is viable in PET/SPECT systems, including the estimation of SUVs. This is only possible if, apart from the above mentioned corrections, the camera is well tuned and coefficients for sensitivity normalization and partial volume corrections are applied. We also verified that the shapes of the sources used for obtaining these factors play a role on the final results and should be delt with carefully in clinical quantification. Finally, the choice of the region

  3. LUCRO, VALOR CONTABIL E DIVIDENDOS NA AVALIAcAO DO PATRIMÔNIO LIQUIDO

    Directory of Open Access Journals (Sweden)

    James A. Ohlson

    2009-09-01

    Full Text Available A contabilidade atribui uma importante função integrativa a demonstração das mutações do patrimônio liquido. A demonstração inclui os itens mais importantes do balanço o e da demonstração de resultado do exercício - o valor do patrimônio liquido e o lucro - e sua forma de apresentação exige que a alteração no valor do patrimônio liquido seja igual ao lucro menos os dividendos (líquidos das contribuições para aumento de capital. Referimo-nos a essa relação corno sendo a “relação de lucro limpo", pois, da forma como foi articulada, todas as alterações nos ativos e passivos que não estejam relacionadas com os dividendos devem passar pela demonstração de resultado do exercício. A teoria da contabilidade adota geralmente esse esquema sem relacioná-lo a perspectiva do usuário dos dados contábeis. Contudo, a idéia fundamental de que estoques (líquidos de valor são compatíveis com a criação c distribuição de valor levanta uma questão básica no contexto de avalia4ao do patrimônio liquido: e possível delinear urna teoria coesiva do valor de uma firma sustentada pela relação de lucro limpo, no intuito de se identificar um papel claro para cada uma das três variáveis, quais sejam: o lucro, o valor contábil do patrimônio liquido e os dividendos?

  4. Computerised Axial Tomography (CAT)

    Science.gov (United States)

    1990-06-01

    Ministry of’ Defence, Defence Research Information Centre, UK. Computerised Axial Tomography ( CAT ) Report Secufty C"uMiauion tide Onadtiicadon (U. R, Cor S...DRIC T 8485 COMPUTERISED AXIAL TOMOGRAPHY ( CAT ) F.P. GENTILE, F. SABETTA, V. TRO1* ISS R 78/4.Rome, 1.5 Mlarch 1978 (from Italian) B Distribution(f...dello Radiazioni ISSN 0390--6477 F.P. GENTILE, F. SABETTA. V. TROI Computerised Axial Tomography ( CAT ) March 15, 1978). This paper is a review of

  5. Quantification in emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-11-01

    The objective of this lecture is to understand the possibilities and limitations of the quantitative analysis of single photon emission computed tomography (SPECT) and positron emission tomography (PET) images. It is also to identify the conditions to be fulfilled to obtain reliable quantitative measurements from images. Content: 1 - Introduction: Quantification in emission tomography - definition and challenges; quantification biasing phenomena 2 - Main problems impacting quantification in PET and SPECT: problems, consequences, correction methods, results (Attenuation, scattering, partial volume effect, movement, un-stationary spatial resolution in SPECT, fortuitous coincidences in PET, standardisation in PET); 3 - Synthesis: accessible efficiency, know-how, Precautions, beyond the activity measurement

  6. Positron emission tomography

    International Nuclear Information System (INIS)

    Wienhard, K.; Heiss, W.D.

    1984-01-01

    The principles and selected clinical applications of positron emission tomography are described. In this technique a chemical compound is labeled with a positron emitting isotope and its biochemical pathway is traced by coincidence detection of the two annihilation photons. The application of the techniques of computed tomography allows to reconstruct the spatial distribution of the radioactivity within a subject. The 18 F-deoxyglucose method for quantitative measurement of local glucose metabolism is discussed in order to illustrate the possibilities of positron emission tomography to record physiological processes in vivo. (orig.) [de

  7. Positron emission tomography imaging of the 18-kDa translocator protein (TSPO) with [{sup 18}F]FEMPA in Alzheimer's disease patients and control subjects

    Energy Technology Data Exchange (ETDEWEB)

    Varrone, Andrea [Centre for Psychiatry Research, Karolinska Institutet, Department of Clinical Neuroscience, Stockholm (Sweden); Karolinska Hospital, Karolinska Institutet, Department of Clinical Neuroscience, Centre for Psychiatry Research, Stockholm (Sweden); Oikonen, Vesa; Joutsa, Juho; Solin, Olof; Haaparanta-Solin, Merja; Rinne, Juha O. [University of Turku, Turku PET Centre, Turku (Finland); Forsberg, Anton; Takano, Akihiro; Nag, Sangram; Nakao, Ryuji; Halldin, Christer [Centre for Psychiatry Research, Karolinska Institutet, Department of Clinical Neuroscience, Stockholm (Sweden); Al-Tawil, Nabil [Karolinska University Hospital, Karolinska Trial Alliance, Stockholm (Sweden); Wells, Lisa A.; Rabiner, Eugenii A. [Imanova Centre for Imaging Sciences, London (United Kingdom); Valencia, Ray; Schultze-Mosgau, Marcus; Thiele, Andrea; Vollmer, Sonja; Dyrks, Thomas; Lehmann, Lutz; Heinrich, Tobias; Hoffmann, Anja [Bayer Healthcare AG, Berlin (Germany); Nordberg, Agneta [Karolinska University Hospital Huddinge, Department of Geriatric Medicine, Stockholm (Sweden)

    2014-11-21

    Imaging of the 18-kDa translocator protein (TSPO) is a potential tool for examining microglial activation and neuroinflammation in early Alzheimer's disease (AD). [{sup 18}F]FEMPA is a novel high-affinity second-generation TSPO radioligand that has displayed suitable pharmacokinetic properties in preclinical studies. The aims of this study were to quantify the binding of [{sup 18}F]FEMPA to TSPO in AD patients and controls and to investigate whether higher [{sup 18}F]FEMPA binding in AD patients than in controls could be detected in vivo. Ten AD patients (five men, five women; age 66.9 ± 7.3 years; MMSE score 25.5 ± 2.5) and seven controls (three men, four women; age 63.7 ± 7.2 years, MMSE score 29.3 ± 1.0) were studied using [{sup 18}F]FEMPA at Turku (13 subjects) and at Karolinska Institutet (4 subjects). The in vitro binding affinity for TSPO was assessed using PBR28 in a competition assay with [{sup 3}H]PK11195 in seven controls and eight AD patients. Cortical and subcortical regions of interest were examined. Quantification was performed using a two-tissue compartment model (2TCM) and Logan graphical analysis (GA). The outcome measure was the total distribution volume (V{sub T}). Repeated measures analysis of variance was used to assess the effect of group and TSPO binding status on V{sub T}. Five AD patients and four controls were high-affinity binders (HABs). Three AD patients and three controls were mixed-affinity binders. V{sub T} estimated with Logan GA was significantly correlated with V{sub T} estimated with the 2TCM in both controls (r = 0.97) and AD patients (r = 0.98) and was selected for the final analysis. Significantly higher V{sub T} was found in the medial temporal cortex in AD patients than in controls (p = 0.044) if the TSPO binding status was entered as a covariate. If only HABs were included, significantly higher V{sub T} was found in the medial and lateral temporal cortex, posterior cingulate, caudate, putamen, thalamus and

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  10. Cardiac positron emission tomography

    International Nuclear Information System (INIS)

    Eftekhari, M.; Ejmalian, G.

    2003-01-01

    Positron emission tomography is an intrinsically tool that provide a unique and unparalleled approach for clinicians and researchers to interrogate the heart noninvasively. The ability to label substances of physiological interest with positron-emitting radioisotopes has permitted insight into normal blood flow and metabolism and the alterations that occur with disease states. Positron emission tomography of the heart has evolved as a unique, noninvasive approach for the assessment of myocardial perfusion, metabolism, and function. Because of the intrinsic quantitative nature of positron emission tomography measurements as well as the diverse compounds that can be labeled with positron- emitting radioisotopes, studies with positron emission tomography have provided rich insight into the physiology of the heart under diverse conditions

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  12. Positron emission tomography

    International Nuclear Information System (INIS)

    Iio, Masahiro

    1982-01-01

    Utilization of positron emission tomography was reviewed in relation to construction and planned construction of small-size medical cyclotrons, planned construction of positron cameras and utilization of short-lived radionuclides. (Chiba, N.)

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for ... Tomography (CT) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head and Neck Cancer top ... Tomography (CT) - Sinuses Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... of the Sinuses? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  1. Intracoronary optical coherence tomography

    DEFF Research Database (Denmark)

    Tenekecioglu, Erhan; Albuquerque, Felipe N; Sotomi, Yohei

    2017-01-01

    By providing valuable information about the coronary artery wall and lumen, intravascular imaging may aid in optimizing interventional procedure results and thereby could improve clinical outcomes following percutaneous coronary intervention (PCI). Intravascular optical coherence tomography (OCT...

  2. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  3. Tomography in nuclear medicine

    International Nuclear Information System (INIS)

    Levi de Cabrejas, Mariana

    1999-01-01

    This book is a contribution to the training and diffusion of the tomography method image diagnosis in nuclear medicine, which principal purpose is the information to professionals and technical personnel, specially for the spanish speaking staff

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the ...

  7. Electrical Impedance Tomography Technology

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal for the Electrical Impedance Tomography Technology (EITT) project is to develop a reliable portable, lightweight device providing two-dimensional...

  8. Introduction to Seismic Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, Charlotte Anne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-21

    Tomography is a method of obtaining an image of a 3d object by observing the behavior of energy transmissions through the object. The image is obtained by Interrogating the object with Energy sources at a variety of Locations and observing the Object’s effects on the energy at a Variety of sensors. Tomography was first Used to build 3-dimensional Scans through Human bodies. These Are called computed Tomographic (ct) scans.

  9. Positron emission tomography

    International Nuclear Information System (INIS)

    Dvorak, O.

    1989-01-01

    The principle is briefly described of positron emission tomography, and its benefits and constraints are listed. It is emphasized that positron emission tomography (PET) provides valuable information on metabolic changes in the organism that are otherwise only very difficult to obtain, such as brain diagnosis including relationships between mental disorders and the physiology and pathophysiology of the brain. A PET machine is to be installed in Czechoslovakia in the near future. (L.O.)

  10. Persistent hyperplastic primary vitreous: imaging evaluation; Persistencia hiperplastica do vitreo primitivo: avaliacao por metodos de imagem

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, Beatriz Mahmud; Teixeira, Kim-Ir-Sen Santos; Figueiredo, Sizenildo da Silva; Nobrega, Bruno Barcelos da [Universidade Federal de Goias, Goiania (Brazil). Hospital das Clinicas. Dept. de Diagnostico por Imagem]. E-mail: biamjacob@hotmail.com

    2003-06-01

    Persistent hyperplastic primary vitreous (PHPV) is a congenital developmental anomaly of the eye that primarily affects premature infants. PHPV results from failure of regression of the embryogenic primary vitreous and hyaloid vasculature, and proliferation of connective tissue. Three types of PHPV may be found: anterior, posterior and a combination of anterior and posterior. The clinical findings include leukocoria (white pupillary reflex) and microphthalmic eye. This anomaly is usually unilateral and unassociated with other systemic findings. The differential diagnosis between PHPV and other ocular diseases may be difficult due to similar features such as leukocoria, detached retina, retinal folds and cataract. Other diseases with similar features include retinoblastoma, isolated congenital cataract, retinopathy of prematurity and pseudo gliomas or leukocorias. Direct visualization of the remnants of the fetal hyaloid vascular system offers the best evidence of PHPV. However, diagnosis using the ophthalmoscope is sometimes impossible because of opaque tissues. In this circumstance an indirect visualization by ultrasound, computed tomography or magnetic resonance imaging may be useful. These imaging methods provide valuable information for the differentiation from other diseases, particularly retinoblastoma. The authors present a review of the literature and an iconographic study of the imaging findings in patients with PHPV. (author)

  11. Influence of ASIR (Adaptative Statistical Iterative Reconstruction) variation in the image noise of computerized tomography for high voltage; Influência da variação do ASIR (Adaptative Statistical Iterative Reconstruction) no ruído da imagem de tomografia computadorizada para altas tensões

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, L.M.M.; Pereira, W.B.R.; Vieira, J.G.; Lamounier, C.S.; Gonçalves, D.A.; Carvalho, G.N.P.; Santana, P.C., E-mail: lucasmoacir2010@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Oliveira, P.M.C.; Reis, L.P., E-mail: paulomarcio2000@gmail.com [Centro de Desenvolvimento de Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Computed tomography had great advances in the equipment used in the diagnostic practice, directly influencing the levels of radiation for the patient. It is essential to optimize techniques that must be employed to comply with the ALARA (As Low As Reasonably Achievable) principle of radioprotection. The relationship of ASIR (Adaptive Statistical Iterative Reconstruction) with image noise was studied. Central images of a homogeneous water simulator were obtained in a 20 mm scan using a 64-channel Lightspeed VCT tomograph of General Electric in helical acquisitions with a rotation time of 0.5 seconds, Pitch 0.984: 1, and thickness of cut 0.625 mm. All these constant parameters varying the voltage in two distinct values: 120 and 140 kV with use of the automatic current by the CAE (Automatic Exposure Control), ranging from 50 to 675 mA (120 kV) and from 50 to 610 mA (140kV), minimum and maximum values, respectively allowed for each voltage. Image noise was determined through ImageJ free software. The analysis of the obtained data compared the percentage variation of the noise in the image based on the ASIR value of 10%, concluding that there is a variation of approximately 50% when compared to the values of ASIR (100%) in both tensions. Dose evaluation is required in future studies to better utilize the relationship between dose and image quality.

  12. Estudo de caso de oferta induzindo a demanda: o caso da oferta de exames de imagem (tomografia axial computadorizada e ressonância magnética na Unimed-Manaus Case study of supply induced demand: the case of provision of imaging scans (computed tomography and magnetic resonance at Unimed-Manaus

    Directory of Open Access Journals (Sweden)

    Edson de Oliveira Andrade

    2011-04-01

    Full Text Available OBJETIVO: Apresentar a experiência de uma operadora de plano de saúde (Unimed-Manaus na cidade de Manaus, Estado do Amazonas, com o credenciamento de serviços de imagem e a indução de demanda pela oferta dos novos serviços (Lei de Roemer. MÉTODOS: Trata-se de uma pesquisa de caráter retrospectivo, com estudo de série temporal, abordando o período de janeiro de 1998 a junho de 2004, lapso de tempo em que ocorreu a implantação dos serviços de tomografia computadorizada e da ressonância magnética no âmbito dos serviços oferecidos por aquele plano de saúde. A análise estatística consistiu em uma parte descritiva e uma inferencial, sendo esta última utilizando teste paramétrico de média (teste t de Student e ANOVA e o teste de correlação de Pearson. Foi adotado um alfa de 5% e um intervalo de confiança de 95%. RESULTADOS: Foi possível identificar na Unimed-Manaus que a oferta de novos serviços de imagem foi capaz de, por si só, gerar um aumento da demanda do serviço caracterizando o fenômeno descrito por Roemer. CONCLUSÃO: Os resultados deste trabalho ressaltam a necessidade de se estar atento ao fato de que a oferta de novos serviços no setor da saúde poderá acarretar, por si só, um aumento de sua utilização sem que haja uma demanda real.OBJECTIVE: To present the experience of a health plan operator (Unimed-Manaus in Manaus, Amazonas, Brazil, with the accreditation of imaging services and the demand induced by the supply of new services (Roemer's Law. METHODS: This is a retrospective work studying a time series covering the period from January 1998 to June 2004, in which the computed tomography and the magnetic resonance imaging services were implemented as part of the services offered by that health plan operator. Statistical analysis consisted of a descriptive and an inferential part, with the latter using a mean parametric test (Student T-test and ANOVA and the Pearson correlation test. A 5% alpha and a 95

  13. 4D Electron Tomography

    Science.gov (United States)

    Kwon, Oh-Hoon; Zewail, Ahmed H.

    2010-06-01

    Electron tomography provides three-dimensional (3D) imaging of noncrystalline and crystalline equilibrium structures, as well as elemental volume composition, of materials and biological specimens, including those of viruses and cells. We report the development of 4D electron tomography by integrating the fourth dimension (time resolution) with the 3D spatial resolution obtained from a complete tilt series of 2D projections of an object. The different time frames of tomograms constitute a movie of the object in motion, thus enabling studies of nonequilibrium structures and transient processes. The method was demonstrated using carbon nanotubes of a bracelet-like ring structure for which 4D tomograms display different modes of motion, such as breathing and wiggling, with resonance frequencies up to 30 megahertz. Applications can now make use of the full space-time range with the nanometer-femtosecond resolution of ultrafast electron tomography.

  14. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  15. Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Mogensen, Mette; Themstrup, Lotte; Banzhaf, Christina

    2014-01-01

    Optical coherence tomography (OCT) has developed rapidly since its first realisation in medicine and is currently an emerging technology in the diagnosis of skin disease. OCT is an interferometric technique that detects reflected and backscattered light from tissue and is often described as the o......Optical coherence tomography (OCT) has developed rapidly since its first realisation in medicine and is currently an emerging technology in the diagnosis of skin disease. OCT is an interferometric technique that detects reflected and backscattered light from tissue and is often described...

  16. Digital multilayer tomography

    International Nuclear Information System (INIS)

    Dueber, C.; Klose, K.J.; Thelen, M.

    1991-01-01

    With digital multilayer tomography a sequence of projection images is recorded by an image intensifier television system and stored as digital data during a linear run of a layer sequence. Using this data record, tomograms of the examined body region can be computed for any layer thickness by shifts and superimposition of the single projections later at a digital workstation. The qualities of digital and conventional tomograms are basically comparable. A drawback of digital tomography is its lower local resolution (512 x 512 image matrix), advantages are a lower radiation exposure, a shorter patient examination time, and the facilities of digital image processing (later processing, archive setup, transmission). (orig.) [de

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  19. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  20. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  5. Computed tomography in traumatology

    International Nuclear Information System (INIS)

    Heller, M.; Jend, H.H.

    1986-01-01

    This volume offers a critical review and assessment of new avenues opened up by computed tomography in traumatology. Over 200 illustrations, including numerous CT scans, aid the physician engaged emergency care and postoperative treatment of accident victims. Technical prerequisites, special techniques of investigation, pathomorphology of organ changes conditioned by trauma, diagnostic leading symptoms and signs, and diagnostics of iatrogenic injuries and lesions are presented

  6. Computed tomography system

    International Nuclear Information System (INIS)

    Lambert, T.W.; Blake, J.E.

    1981-01-01

    This invention relates to computed tomography and is particularly concerned with determining the CT numbers of zones of interest in an image displayed on a cathode ray tube which zones lie in the so-called level or center of the gray scale window. (author)

  7. Holography and tomography

    Energy Technology Data Exchange (ETDEWEB)

    Howells, M. [Lawrence Berkeley National Lab., CA (United States)

    1997-02-01

    This session includes a collection of outlines of pertinent information, diagrams, graphs, electron micrographs, and color photographs pertaining to historical aspects and recent advances in the development of X-ray Gabor Holography. Many of the photographs feature or pertain to instrumentation used in holography, tomography, and cryo-holography.

  8. Celebral computerized tomography

    International Nuclear Information System (INIS)

    Lofteroed, B.; Sortland, O.

    1985-01-01

    Indications for cerebral computerized tomography (CT) and the diagnostic results from this examination are evaluated in 127 children. Pathological changes were found in 31 children, mostly based on such indications as increasing head size, suspicion of brain tumor, cerebral paresis, delayed psychomotor development and epileptic seizures. A list of indications for CT in children is given

  9. Positron emission tomography

    International Nuclear Information System (INIS)

    Pavuk, M.

    2003-12-01

    The aim of this project is to provide a simple summary of new trends in positron emission tomography and its basic physical principles. It provides thereby compendious introduction of the trends of the present development in diagnostics using PET systems. A review of available literature was performed. (author)

  10. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  11. Positron emission tomography

    NARCIS (Netherlands)

    Paans, AMJ

    Positron Emission Tomography (PET) is a method for determining biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides as C-11, N-13, O-15 and F-18 and by measuring the annihilation radiation using a

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  14. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  15. Holography and tomography

    International Nuclear Information System (INIS)

    Howells, M.

    1997-01-01

    This session includes a collection of outlines of pertinent information, diagrams, graphs, electron micrographs, and color photographs pertaining to historical aspects and recent advances in the development of X-ray Gabor Holography. Many of the photographs feature or pertain to instrumentation used in holography, tomography, and cryo-holography

  16. Evaluation of the fuel rod integrity in PWR reactors from the spectrometric analysis of the primary coolant; Avaliacao da integridade de varetas combustiveis em reatores PWR a partir da analise espectrometrica da agua do primario

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Iara Arraes

    1999-02-15

    The main objective of this thesis is to provide a better comprehension of the phenomena involved in the transport of fission products, from the fuel rod to the coolant of a PWR reactor. To achieve this purpose, several steps were followed. Firstly, it was presented a description of the fuel elements and the main mechanisms of fuel rod failure, indicating the most important nuclides and their transport mechanisms. Secondly, taking both the kinetic and diffusion models for the transport of fission products as a basis, a simple analytical and semi-empirical model was developed. This model was also based on theoretical considerations and measurements of coolant's activity, according to internationally adopted methodologies. Several factors are considered in the modelling procedures: intrinsic factors to the reactor itself, factors which depend on the reactor's operational mode, isotope characteristic factors, and factors which depend on the type of rod failure. The model was applied for different reactor's operational parameters in the presence of failed rods. The main conclusions drawn from the analysis of the model's output are relative to the variation on the coolant's water activity with the fuel burnup, the linear operation power and the primary purification rate and to the different behaviour of iodine and noble gases. The model was saturated from a certain failure size and showed to be unable to distinguish between a single big fail and many small ones. (author)

  17. Evaluation of the contribution of contamination of radiotherapy room surfaces in the measure of exposure rate of radioiodine therapy patients; Avaliacao da contribuicao da contaminacao de superficies do quarto terapeutico na medida da taxa de exposicao de pacientes de radioiodoterapia

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Rafael Ferreira

    2015-07-01

    The contamination of radiotherapy room surfaces is significant and the measures of patient exposure rate are held on the fourth dependencies, relevant questions are raised: the background radiation of the room stay high due to surface contamination, may interfere with the rate of patient exposure at the time of its release? The monitoring site is important to determine whether the patient will be released? The value of the deal activity and the clinical condition of the patient may increase the contamination, influencing the monitoring results? This paper aims to conduct a quantitative analysis of surface contamination of the contribution of therapeutic room at the time is monitored exposure rate from inpatient. Measurements were made regarding the hospitalization of 32 patients with different doses administered activity, age and of both genders. The measurements were performed in the therapeutic rooms at the hospital Brotherhood Santa Casa de Misericordia de Sao Paulo. Exposure rate measurements were performed at the center of the room at 1 meter of the patient on the day of its release. After his release and prior to decontamination, measurements were performed at predetermined landmarks within the therapeutic room. The results revealed that on average background radiation, high due to surface contamination contributes only 2% of the patient dose rate. It can be considered that even with influence of contamination of surfaces, this is insignificant to determine if the patient may or may not be released. This study suggests that the site in which monitoring occurs exposure rate of the patient should not be decisive for liberation thereof. (author)

  18. Phytochemical study and evaluation of anti-inflammatory activity of Aeschynomene fluminensis Vell. (Fabaceae); Estudo fitoquimico e avaliacao da atividade anti-inflamatoria de Aeschynomene fluminensis Vell. (Fabaceae)

    Energy Technology Data Exchange (ETDEWEB)

    Ignoato, Marlene Capelin; Fabrao, Rodrigo Monteiro; Schuquel, Ivania Teresinha Albrecht; Botelho, Marcos Felipe Pinatto; Santin, Silvana Maria de Oliveira [Universidade Estadual de Maringa (UEM) PR (Brazil). Dept. de Quimica; Arruda, Laura Licia Milani de; Bersani-Amado, Ciomar Aparecida [Universidade Estadual de Maringa (UEM) PR (Brazil). Dept. de Farmacologia e Terapeutica; Souza, Maria Conceicao de, E-mail: smoliveira@uem.br [Universidade Estadual de Maringa (UEM) PR (Brazil). Dept. de Biologia

    2012-07-01

    Phytochemical investigation of Aeschynomene fluminensis leaves and branches led to isolation of the flavonoid glycosides kaempferol 3,7-di-O-{alpha}-L-rhamnopyranoside, kaempferol 7-O-{alpha}-L-rhamnopyranoside, kaempferol 3-O-apiofuranosil-7-O- rhamnopyranoside, quercetin 3-O-{alpha}-L-rhamnopyranoside, quercetin 3-O-arabinofuranoside, 8-{beta}-D-glucopyranosyl 4',5,7-trihydroxyflavanone, the isoflavonoid 4',7-di-hydroxy-isoflavone, the dimer epicatechin-(2{beta} ->7, 4{beta} ->8)- epicatechin, the polyol 3-O-methyl-chiro-inositol and two steroids in sitosterol and stigmasterol mixture. These compounds were identified by NMR {sup 1}H and {sup 13}C and compared with literature data. Anti-inflammatory activity of the crude methanolic extract and its fractions was evaluated (author)

  19. Evaluation of pollution effects in transmission lines located in industrial areas; Avaliacao dos efeitos da poluicao em linhas de transmissao situadas em regiao industrial

    Energy Technology Data Exchange (ETDEWEB)

    Kanashiro, Arnaldo G.; Burani, Geraldo F. [Sao Paulo Univ., SP (Brazil). Inst. de Eletrotecnica e Energia; Nascimento, Iara R. [Eletricidade de Sao Paulo SA, SP (Brazil)

    1995-12-31

    This work aims to determinate a correlation between the pollution levels and electric power transmission lines maintenance procedures in order to establish the necessary procedures for specific pollution levels. The methodology is presented. The results obtained in field tests and bench scale tests are presented and discussed. The so called pollution equivalent is determined for each site of the transmission line studied and maintenance procedures are established 6 refs., 5 figs., 4 tabs.

  20. Evaluation of morphological changes of the skin after radiation-induced injury in Wistar rats;Avaliacao de alteracoes morfologicas da pele apos lesao radioinduzida em ratos Wistar

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Cherley Borba Vieira de

    2010-07-01

    The cancer covers a heterogeneous group of more than 100 diseases with different etiology and prognosis. Radiotherapy is one of the most commonly used treatment modalities, aiming at the destruction of cancer cells, using ionizing radiation. One of the limiting factors of radiotherapy is that radiation promotes the death of tumor cells in addition to injure healthy tissue neighboring the tumor, and may cause their death. Irradiation of the skin, accidental or for therapeutic purposes can trigger many injuries culminating in fibrosis, which implies functional alteration of the body. The evaluation of morphological effects associated with skin irradiation becomes essential to develop more effective radiation strategies and decreased morbidity; and in case of accidents, proper handling of the victim.Evaluate radio-induced dermal changes using a Wistar rats model irradiated with 10, 40 and 60Gy. Male Wistar rats, aged approximately three months, were pre-anesthetized with midazolam and xylazine and anesthetized with sodium pentobarbital, shaved in the back, immobilized on polystyrene support in the prone position and irradiated with doses of 10, 40 and 60 Gy, with 4MeV nominal energy electron beams. The skin was irradiated in a 3cm{sup 2} field, and used 0.5cm of tissue equivalent material, to obtain a homogeneous dose distribution. After irradiation, the animals remained on constant evaluation, and the lesions were recorded photographically. The animals were divided into groups and were killed on the irradiation day, 5, 10, 15, 25 and 100 days after irradiation. The skin was fixed in 10% formaldehyde; the samples were embedded in paraffin and cut. The sections were stained with hematoxylin-eosin, picrosirius red and immuno stained with antibody anti-TGF beta1. Another part of the tissue was fixed in 2.5% glutaraldehyde and processed for scanning electron microscopy. It was observed macroscopically the appearance of skin lesions similar to burns on the entire irradiated area. The optical microscope verified the early development of lesions in the 5 days group. After 10 days of irradiation it was already possible to see evidences of epidermal healing under the crust formed by the lesion. At 15 days after irradiation the tissue beneath the lesion had reconstructed epidermis. It was also observed the characteristics of tissue healing. It was also seen a significant polymorphonuclear cells infiltration. After 25 days at the higher doses the lesions remained, which did not occur at the lower dose, where the irradiated area of the animals were already completely healed. After 100 days of irradiation at 40Gy dose the wound was healed with the emergence of a well defined healed tissue. At the 60Gy dose, the lesion persisted in some animals, and in those that healing occurred the epidermis was a hypertrophied (acanthosis). It was visualized a tissue with their morphological aspect completely mis characterized, where it's possible to view a necrotic tissue. The results of the scanning electron microscopy analysis corroborate with the in optical microscopy findings, where it's possible to visualize the distortion of collagen fibers at the higher dosages. The results indicate that the used doses induced an important skin inflammatory process, activating the immune system. This fact leads to an increase in the expression of TGF beta1, one of the responsible for the increased production of extracellular matrix (ECM) by various cell types, mainly fibroblasts in injured tissues. Besides the increased expression of ECM, the TGF beta1 also promotes the inhibition of the degradation processes of the same. The intense expression of cytokines in irradiated skin can trigger the fibrosis process; consequently, affect the homeostasis of this organ due to the accumulation of ECM. (author)

  1. Evaluation of dosimetric effects caused by the table top of therapy; Avaliacao dos efeitos dosimetricos causados pelo tampo da mesa de tratamento

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, Andre Vinicius de; Alvares, Bruno; Fioravante, Gustavo Donisete; Silva, Diego da Cunha Silveira Alves da; Giglioli, Milena; Batista, Felipe Placido; Silva, Lais Bueno da; Radicchi, Lucas Augusto [Hospital de Cancer de Barretos, SP (Brazil)

    2016-07-01

    The attenuation and bolus effect for two tables top from different manufacturers were investigated for 6MV photons. The bolus effect of couch was compared with 0,5cm bolus (water equivalent). Maximum attenuation found in Exact Couch table was 6,9% and the minimum was 0,63%. The rail of Exact Couch, for beam in 180 deg, was observed attenuation of 13,61%. The same way that for attenuation, the surface dose was different for each region of couch Exact Couch and for different components of iBeam evo. The percentage of the dose in the depth of 1,8 mm was greater for table top of Exact Couch (66,2%). The extender of table iBeam evo offered increase dose of 38,3% and it table top of 51,9% in the same depth. The bolus increased surface dose in 61,1%. The results of this study showed that table tops when in contact with surface of the patient may significantly increase surface dose and beam attenuation. (author)

  2. Evaluation of quality of tomographs of Rio de Janeiro state, Brazil; Avaliacao da qualidade dos tomografos do estado do Rio de Janeiro

    Energy Technology Data Exchange (ETDEWEB)

    Travassos, P.C.B.; Belem, V.R.; Magalhaes, L.A.; Almeida, C.E.A. de, E-mail: luisalexandregm@hotmail.com [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. de Ciencias Radiologicas

    2014-07-01

    Computerized tomographs used in 56 institutions in the state of Rio de Janeiro were evaluated. Criteria of image quality and dosimetry were submitted. The results showed that some not performed optimize their protocols examinations or perform wrongly, which results in an increase in the dose received by patients, and an image in compromised quality. (author)

  3. Assessment of effect of chemical treatment to carnauba's fibers straw; Avaliacao do efeito de tratamento quimico as fibras da palha de carnauba

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, T.M.P. de; Carvalho, L.F.M.; Oliveira, R.R. de; Sousa, F.M.S. de; Sousa, R.C. de; Marques, J.R., E-mail: thaismarjore.pc@gmail.com [Instituto Federal de Educacao, Ciencia e Tecnologia do Piaui (IFPI), Teresina, PI (Brazil)

    2016-07-01

    The use of natural fibers in composite materials has been highlighted in the scientific field. However, its application in polymer matrices usually requires surface modifications. The objective of this work was to treat carnauba's straw fibers with NaOH 1 % and NaOH 5% solutions and measure the water absorption. We used the X-ray diffraction (XRD configuration “Bragg- Brentano) for verification of the crystalline phases and Fourier Transform Infrared Spectroscopy (FTIR) to identify functional groups. The alkali treatment allowed the solubilization of the hemicellulose and lignin without causing changes to cellulose, as indicated by FTIR spectrophotometry and by the increase in crystallinity content. The samples showed the typical peaks of constituents of the fiber. The natural fiber showed an average water absorption of 256 %; fiber treated with NaOH 1%, 315 %; and treated with NaOH 5%, 405 %. Therefore, it is evident improvement in hydrophilicity, fundamental aspect in the interaction fiber / matrix. (author)

  4. Morpho-functional study of ionizing radiation effects on the rabbits` femoral vein; Avaliacao morfofuncional do efeito da radiacao ionizante sobre a veia femoral. Estudo experimental em coelhos

    Energy Technology Data Exchange (ETDEWEB)

    Sakiyama, Mauro Yoshimitsu

    1996-12-31

    In this study we evaluate the effects of the ionizing radiation on the rabbits femoral vein. The samples of femoral vein were obtained from 56 New Zealand rabbits, male with ageing from 90 to 120 days, that were divided into 4 groups of 14 animals: one control group non-irradiated and three animal groups sacrificed 2 days, 14 days and 90 days after irradiation. In the three irradiated rabbits groups, each animal received the total dose 4000 cGy (rads) divided in 10 sessions of 400 cGy, a dose equivalent that utilized on clinical therapeutic. A morpho functional study of vein samples was carried out with: light microscopy: stained by hematoxin - eosin, Masson`s tricromic, and Verhoeff. Immunohistochemical: reactions of immunoperoxidase with monoclonal mouse anti-human endothelial cell factor CD-31 and anti-human Von Willebrand factor (factor VIII), to study the vein endothelium. Histomorphometry of elastic fiber system stained by Weigert`s resorcin-fuchsin with and without prior oxidation with oxone; for the study of mature, elaunin or pre-mature and oxytalan or young elastic fibers. Electronic microscopy: transmission and scanning. With the methodology utilized we observe changes in the femoral vein of the animals submitted to irradiation in relation to the control group, thus described: there is formation of vacuoles between the endothelium and the basal membrane, called sub endothelial vacuoles, in focal areas. The factor VIII and CD-31 endothelial antigens are preserved with no changes in their functions. Focal alterations are present in the endothelial surface with disorder in the setting and orientation of the endothelial cells. there is degeneration of the elastic fibers with significant decrease in their quantity in the stage, 2 days and 14 days after irradiation. There is increase in the quantity of elastic fibers in the late stage, 90 days after irradiation, tending to normality. In this present study, the changes described are not accompanied by venous thrombosis. (author) 101 refs., 22 figs., 2 tabs.

  5. Magnetic resonance imaging pre- and postoperative evaluation of tetralogy of Fallot; Avaliacao pre e pos-operatoria da tetralogia de Fallot por ressonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Bernardes, Renata Junqueira Moll; Simoes, Luiz Carlos [Instituto Nacional de Cardiologia (INC), Rio de Janeiro, RJ (Brazil). Servico de Cardiologia da Crianca e do Adolescente; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Faculdade de Medicina. Dept. de Radiologia]. E-mail: edmarchiori@bol.com.br; Bernardes, Paulo Manuel de Barros; Gonzaga, Maria Beatriz Albano Monzo [Rede Labs/D' Or, Rio de Janeiro, RJ (Brazil)

    2004-08-01

    The purpose of this study was to assess the usefulness of magnetic resonance imaging (MRI) in the pre- and postoperative evaluation of patients with tetralogy of Fallot. Twenty patients aged 1 to 29 years were prospectively evaluated with black-blood and contrast-enhanced angiographic techniques, 11 with the classic form of tetralogy of Fallot and 9 with tetralogy of Fallot and pulmonary atresia. MRI studies provided adequate visualization of the aorta that was classified as dilated or not dilated, and definition of its position in all cases. The use of contrast-enhanced MR angiographic techniques provided excellent imaging of the main right and left pulmonary arteries. The results suggest that MRI, including contrast-enhanced angiography techniques, is a useful tool in the evaluation of patients with tetralogy of Fallot before and after cardiac surgery since it provides important anatomical information that is not always obtained with echocardiography. MRI can be considered an alternative to cardiac catheterization, particularly in the evaluation of the pulmonary vascular anatomy. (author)

  6. Evaluation of radon measuring technique using passive detector activated carbon; Avaliacao da tecnica de medicao do radonio utilizando detector passivo com carvao ativado

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Paulo Roberto Rocha; Lessa, Edmilson de Lima; Oliveira, Evaldo Paulo de, E-mail: epoliveira@aluno.ird.gov.br [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Radioprotecao Ambiental e Ocupacional

    2014-07-01

    This study aims to evaluate the efficiency of measuring the radioactive gas Radon ({sup 222} Rn) with passive detector activated carbon. Alpha Guard, exposure chamber, air sampler, default font Radio, calibrator flow, flow adjuster, ducts drivers: For this, various equipment to make the measurement system as were used. An assembly of such equipment, with specific sequence was used allowing for more efficient exposure of passive detectors Radon gas. Twenty samples were heated to remove moisture and then stored in desiccator until the experiment were made. The exhibition was held passive dosimeters being removed from the chamber, and one hour after, subjected to analysis by gamma spectrometry in germanium (HPGe) for an hour. Subsequently, other measurements were made at scheduled times and sequential for one hour. The results were presented in report form and spectra, measures and graphs generated by Alpha Guard were also extracted. Finally we calculated the efficiency of the passive meter activated carbon. (author)

  7. Glass forming ability of the Al-Ce-Ni system; Avaliacao da capacidade de formacao vitrea do sistema Al-Ce-Ni

    Energy Technology Data Exchange (ETDEWEB)

    Triveno Rios, C. [Engenharia Mecanica, Universidade Federal de Mato Grosso, Rondonopolis, MT (Brazil)], e-mail: triveno@ufmt.br; Surinach, S.; Baro, M.D. [Departamento de Engenharia de Materiais - Universidade Federal de Sao Carlos, SP (Brazil); Bolfarini, C.; Botta, W.J.; Kiminami, C.S. [Departamento de Fisica da Universidade Autonoma de Barcelona, Bellaterra (Spain)

    2010-07-01

    In the present work, the glass forming ability (GFA) and its compositional dependence on Al-Ni-Ce system alloys were investigated in function of several thermal parameters. Rapidly quenched Al{sub 85}Ni{sub 15}-{sub X}Ce{sub X} (X=4,5,6,7,10), Al{sub 90}Ni{sub 5}Ce{sub 5}, Al{sub 89}Ni{sub 2}.{sub 4}Ce{sub 8}.{sub 6}, Al{sub 80}Ni{sub 15.6}Ce{sub 4}.{sub 4} and Al{sub 78}Ni{sub 18.5}Ce{sub 3.5} amorphous ribbons were produced by melt-spinning and the structural transformation during heating was studied using a combination of X-ray diffraction (XRD) and differential scanning calorimetry (DSC). The results showed that the GFA and the thermal stability in the Al-rich corner of Al- Ni-Ce system alloys were enhanced by increasing the solute content and specifically the Ce content (author)

  8. Morpho-functional study of ionizing radiation effects on the rabbits` femoral vein; Avaliacao morfofuncional do efeito da radiacao ionizante sobre a veia femoral. Estudo experimental em coelhos

    Energy Technology Data Exchange (ETDEWEB)

    Sakiyama, Mauro Yoshimitsu

    1995-12-31

    In this study we evaluate the effects of the ionizing radiation on the rabbits femoral vein. The samples of femoral vein were obtained from 56 New Zealand rabbits, male with ageing from 90 to 120 days, that were divided into 4 groups of 14 animals: one control group non-irradiated and three animal groups sacrificed 2 days, 14 days and 90 days after irradiation. In the three irradiated rabbits groups, each animal received the total dose 4000 cGy (rads) divided in 10 sessions of 400 cGy, a dose equivalent that utilized on clinical therapeutic. A morpho functional study of vein samples was carried out with: light microscopy: stained by hematoxin - eosin, Masson`s tricromic, and Verhoeff. Immunohistochemical: reactions of immunoperoxidase with monoclonal mouse anti-human endothelial cell factor CD-31 and anti-human Von Willebrand factor (factor VIII), to study the vein endothelium. Histomorphometry of elastic fiber system stained by Weigert`s resorcin-fuchsin with and without prior oxidation with oxone; for the study of mature, elaunin or pre-mature and oxytalan or young elastic fibers. Electronic microscopy: transmission and scanning. With the methodology utilized we observe changes in the femoral vein of the animals submitted to irradiation in relation to the control group, thus described: there is formation of vacuoles between the endothelium and the basal membrane, called sub endothelial vacuoles, in focal areas. The factor VIII and CD-31 endothelial antigens are preserved with no changes in their functions. Focal alterations are present in the endothelial surface with disorder in the setting and orientation of the endothelial cells. there is degeneration of the elastic fibers with significant decrease in their quantity in the stage, 2 days and 14 days after irradiation. There is increase in the quantity of elastic fibers in the late stage, 90 days after irradiation, tending to normality. In this present study, the changes described are not accompanied by venous thrombosis. (author) 101 refs., 22 figs., 2 tabs.

  9. Dynamic system for the evaluation of CIM monitoring and control techniques; Sistema dinamico para avaliacao de tecnicas de monitoracao e controle da CIM

    Energy Technology Data Exchange (ETDEWEB)

    Penna, Monica de Oliveira [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES). Biotecnologia e Ecossistemas]. E-mail: mpena@cenpes.petrobras.com.br; Baptista, Walmar; Brito, Rosane Fernandes de [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES). Tecnologia de Materiais, Equipamentos e Corrosao]. E-mails: walmar@cenpes.petrobras.com.br; rosanef@cenpes.petrobras.com.br; Silva, Edilson Domingos da; Nascimento, Juliana Rangel do [Fundacao Gorceix, Ouro Preto, MG (Brazil)]. E-mails: edilson@cenpes.petrobras.com.br; julianarn@cenpes.petrobras.com.br; Coutinho, Claudia M.L.M. [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Inst. de Biologia. Dept. de Biologia Celular e Molecular

    2002-03-01

    In general, the two main problems associated to the water injection system for secondary petroleum recovery are the corrosion control and the decrease in solid injection in the reservoir. Corrosion problems in injection water systems may have abiotic as well as biotic causes, and the occurrence of reservoir plugs can result from the injection of particles (suspended solids as well as corrosion products), bacteria and fouling formation. Due to the need to implement a methodology for the evaluation of abiotic and biotic corrosive processes, monitoring techniques and MIC control in a dynamic system, an apparatus was built that simulates the characteristics of a water injection system. The apparatus allows monitoring and control of the parameters that, when varied, may influence the performance of the quality of the injected water. The dynamic system was designed to simulate as precisely as possible the conditions that allow the SRB and heterotrophic bacteria to create fouling in a water injection system. This article discusses the dynamic system, analytical methods and some preliminary results. (author)

  10. Evaluation of average glandular dose in digital and conventional systems of the mammography; Avaliacao da dose glandular media em sistemas digitais e convencionais de mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Xavier, Aline C.S.; Barros, Vinicius S.M.; Khoury, Hellen J., E-mail: alinecx90@gmail.com, E-mail: vsmdbarros@gmail.com, E-mail: hjkhoury@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Mello, Francisca A. de, E-mail: francissamello@yahoo.com.br [Hospital das Clinicas do Recife (HCR/UFPE), PE (Brazil)

    2014-07-01

    Mammography is currently the most effective method of diagnosis and detection of breast pathologies. The main interest in this kid of exam comes from the high incidence rate of breast cancer and necessity of high quality images for accurate diagnosis. Digital mammography systems have several advantages compared to conventional systems, however the use of digital imaging systems is not always integrated to an image acquisition protocol. Therefore, it is questionable if digital systems truly reduce the dose received by the patient, because many times is introduced in the clinics without optimization of the image acquisition protocols. The aim of this study is to estimate the value of incident air Kerma and average glandular dose (AGD) in patients undergoing conventional and digital mammography systems in Recife. This study was conducted with 650 patients in three hospitals. The value of incident air Kerma was estimated from the measurement of the yield of equipment and irradiation parameters used for each patient. From these results and using the methodology proposed by Dance et al. the value of the average glandular dose was calculated. The results obtained show that the lowest value of AGD was found with conventional screen-film system, indicating that the parameters for image acquisition with digital systems are not optimized. It was also observed that the institutions with digital systems use lower breast compression values than the conventional. (author)

  11. Assessment pozzolanicity waste red ceramics produced in Valley Assu / RN; Avaliacao da atividade pozolanica dos residuos de ceramica vermelha produzidos no Vale do Assu / RN

    Energy Technology Data Exchange (ETDEWEB)

    Palhares, Rodolfo de Azevedo; Pereira, Arthur Ruan da Silva; Cabral, Kleber Cavalcanti; Nobrega, Andreza Kelly Costa, E-mail: rodolfo.palhares@hotmail.com, E-mail: arthurruan_rn@hotmail.com, E-mail: kleber.cabral@ufersa.edu.br, E-mail: akcn123@hotmail.com [Universidade Federal Rural do Semi-Arido (UFERSA), Mossoro, RN (Brazil). Departamento de Ciencias Exatas

    2016-07-01

    It is known that both the cement industry as a ceramist contribute much to the generation of environmental impacts. Be the Co2 in the atmosphere, as well as the generation of excessive waste, reaching 20%. The objective of this study is to analyze the potential pozollanic of waste from the red ceramic industries Valley Assu / RN, in order that this material can be incorporated as alternative raw material in the manufacture of ecological and similar brick, replacing partially in its composition Portland cement. Thus contributing to reducing the environmental impact produced by both the ceramics industry, such as cement. To evaluate the efficiency of pozollanic material, it was made sample preparation and then the physico-chemical characterization. After performing tests, it was noticed that the material has the minimum requirements established in standard to be considered as pozollanic material. (author)

  12. Falling hammer use evaluation for hot deformation hardness testing; Avaliacao do uso de um martelo de queda, para a determinacao da resistencia a deformacao a quente

    Energy Technology Data Exchange (ETDEWEB)

    Beck, J.C.P.C.; Cauduro, Carlos R.; Schaeffer, Lirio [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil)

    1990-12-31

    This work performs a evaluation of the characteristics hot leaking of a 8620 stainless steel, deformed at 870 deg C. The tools associated with the measurements was described and a comparison between the theoretical values and the values experimentally obtained from the performed tests. 5 figs., 3 refs.

  13. Magnetic resonance imaging of sella turcica: evaluation of patients with galactorrhea, amenorrhea and hyperprolactinemia; Ressonancia magnetica da sela turca: avaliacao de pacientes com galactorreia, amenorreia e hiperprolactinemia

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Alair Augusto Sarmet M.D. dos [Hospital Universitario Antonio Pedro, Niteroi, RJ (Brazil). Dept. de Radiologia; Moreira, Denise Madeira [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Dept. de Radiologia; Andreiuolo, Pedro Angelo [Beneficencia Portuguesa de Niteroi, RJ (Brazil). Servico de Radiologia Santa Cruz Scan

    1999-08-01

    We have selected 135 cases of patients who have done magnetic resonance imaging of sella region, carried out from September, 1991 to August, 1996, who had galactorrhea (G), amenorrhea(A), and hyperprolactinemia (H), isolated or in association. The patients were divided in seven groups, according to the presence of these symptoms and signs. All examinations were made in a private clinic in the city of Rio de Janeiro, Brazil. Correlating these patients with the results of the magnetic resonance images, we found 57 micro adenomas, 31 normal examinations, 22 macro adenomas, 11 pituitary hyperplasias, 7 empty sella and 7 cases included in other aspects. The micro adenoma predominated in groups 1 (GAH), 2 (GH), 3 (HA) and 5 (H), that is, in all groups whose patients had hyperprolactinemia. In macro adenomas, a bright signal on T 1-weighted images indicates pituitary apoplexy with intratumoral hemorrhage. All in all, the magnetic resonance imaging is excellent method to be used in the evaluation of patients with changes in the hypothalamic-pituitary axis. (author)

  14. Evaluation of occupational exposure during the exploration and physical processing of monazite; Avaliacao das exposicoes ocupacionais durante as etapas de exploracao e beneficiamento fisico da monazita

    Energy Technology Data Exchange (ETDEWEB)

    Farias, Joao Torres de

    2006-07-01

    In Brazil the most important concentrations of monazite sands occur in the beaches and sandbanks that extend throughout the coast, from the State of Rio Grande do Norte down to the State of Rio Grande do Sul, Brazil. Nowadays, the most important Brazilian monazite concentrations - considered as being the fourth worldwide reservoir of rare-earth elements - are located at the north seacoast of the State of Rio de Janeiro, near Buena town. At this location the Brazilian Nuclear Industries - INB - manages an industrial complex for prospecting, mining and physical separation and concentration of monazite sands. Among the elements present at the monazite sands there are the radioelements thorium and uranium, which make the monazite sand a radioactive mineral. Monazite is constituted basically of 62% in TR{sub 2}0{sub 3} (rare-earth oxides), 5,5% of thorium in Th0{sub 2} (thorium oxide) and 0,25% of uranium in U{sub 3}0{sub 8} (uranium oxide). The general objective of the present work was to estimate the occupational doses at the industrial complex for prospecting, mining and physical separation and concentration of monazite sands located at Buena, at the north of the State of Rio de Janeiro. The occupational exposures occur mainly through the inhalation of airbone dust particles of mineraIs containing thorium and uranium, during the prospection and physical separation and concentration of monazite. To evaluate the impact of the occupational exposures during the physical separation and concentration of monazite, it was necessary to evaluate the effective equivalent doses due to thorium contamination of the air and the exposures due to the daughter radionuclides from the natural series of uranium and thorium. The results obtained at the present work showed that, although occupational doses are within the annual dose limits established by the Brazilian regulatory authority - CNEN - in some of the working places within the industrial complex the concentrations of radionuclides in air are above the maximum recommended levels. (author)

  15. Synthesis and preliminary evaluation of N-acylhydrazone compounds as antibacterial and antifungal agents; Sintese e avaliacao preliminar da atividade antibacteriana e antifungica de derivados N-acilidrazonicos

    Energy Technology Data Exchange (ETDEWEB)

    Cachiba, Thomas Haruo; Carvalho, Bruno Demartini; Carvalho, Diogo Teixeira [Universidade Federal de Alfenas, MG (Brazil). Fac. de Ciencias Farmaceuticas. Dept. de Alimentos e Medicamentos; Cusinato, Marina; Prado, Clara Gaviao; Dias, Amanda Latercia Tranches, E-mail: diogo.carvalho@unifal-mg.edu.br [Universidade Federal de Alfenas, MG (Brazil). Inst. de Ciencias Biomedicas

    2012-07-01

    We describe the synthesis and evaluation of N-acylhydrazone compounds bearing different electron-donating groups in one of its aromatic rings, obtained using a four-step synthetic route. IC{sub 50} values against pathogenic fungi and bacteria were determined by serial microdilution. Compounds showed low activity against Staphylococcus aureus, Escherichia coli and Pseudomonas aeruginosa. By contrast, a derivative with a meta-oriented electron-donating group showed significant activity (IC50) against Candida albicans (17 {mu}M), C. krusei (34 {mu}M) and C. tropicalis (17 {mu}M). Results suggest this is a promising lead-compound for synthesis of potent antifungal agents. (author)

  16. Assessment of activity of nitrate-reducing bacterial souring control; Avaliacao da atividade de bacterias redutoras de nitrato no controle de acidificacao de reservatorios de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Sousa, Kally A. de; Cammarota, Magali C.; Servulo, Eliana F.C. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Escola de Quimica

    2008-07-01

    The effect of nitrate addition in relation to NRB concentration was evaluated on biogenic H{sub 2}S generation in anaerobic microcosms with produced water. A 2{sup k} factorial experimental design was performed by using as response variables nitrate (NO{sub 3}{sup -}) and sulfate (SO{sub 4}{sup =}) consumption and nitrite (NO{sub 2}{sup -}) and sulfide (H{sub 2}S) production and as independent variables the SRB and NRB (10{sup 1} - 10{sup 7} MPN/mL) and NO{sub 3}{sup -} (127.5 - 727.5 mg/L) initial concentrations. Each condition was carried out under incubation at 30 deg C during 7, 14 and 28 days. The lowest sulfide production (0.4 - 0.8 mg/L) was achieved for 10{sup 4} MPN/mL of SRB and NRB and 427.5 mg/L nitrate. Also, a reduction of sulfide generation was obtained by nitrate addition when low SRB and NRB concentrations were established. In such condition, the produced sulfide is rather dependent of nitrate concentration. The increase of the NRB concentration has not resulted in the reduction of sulfide production, even when higher nitrate concentrations were used. (author)

  17. Photoluminescence evaluation of TiO{sub 2} synthesized by Pechini method; Avaliacao da fotoluminescencia do TiO{sub 2} sintetizado pelo metodo Pechini

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, D.S.; Diniz, V.C.S.; Dantas, J.; Araujo, P.M.A.G.; Costa, A.C.F.M., E-mail: dagobertoufcg@gmail.com [Universidade Federal de Campina Grande (UFCG), PB (Brazil). Programa de Pos-Graduacao em Ciencia e Engenharia de Materiais; Viana, R.S.; Junior, S.A. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. Quimica Fundamental; Torquato, R.A. [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil). Dept. de Engenharia de Materiais

    2017-07-15

    Titanium dioxide (TiO{sub 2}) stands out for use in various applications mainly due to its properties of thermal and chemical stability and its excellent optical properties. However, these properties are dependent on the type and phase morphology, which is related to the TiO{sub 2} processing method. Thus, this paper proposed to synthesize TiO{sub 2} nanoparticles by polymeric precursor method with different polymorphs, and evaluate the influence of these phases in the photoluminescent properties. For this, the stoichiometric molar proportions of citric acid:metallic cations of 1:1, 2:1, 3:1, 4:1 and 5:1 were investigated. The nanoparticles were characterized by X-ray diffraction (XRD), infrared spectroscopy, textural analysis, scanning electron microscopy (SEM), excitation and emission spectroscopy and determination of the band gap by UV-Vis diffuse reflectance spectroscopy. The presence of anatase and rutile was confirmed by XRD in different proportions for each sample. The agglomerate size increased with the citric acid/metal cations ratio as observed by SEM. Concerning photoluminescence, the maximum intensity in the emission spectrum occurred at the wavelength of 533 nm for the 3:1 sample and the maximum intensity in the excitation spectrum occurred for the 2:1 sample at the wavelength of 451 nm. (author)

  18. Radiographic and tomographic study of the elbow joint in dogs; Avaliacao morfologica e morfometrica da articulacao umerorradioulnar em caes atraves de exames radiograficos e por tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Sendyk-Grunkraut, Alessandra; Martin, Claudia M.; Souza, Alexandre N.A.; Patricio, Geni Cristina F.; Lorigados, Carla A.B.; Matera, Julia M.; Fonseca-Pinto, Ana C.B.C., E-mail: anacarol@usp.br [Universidade de Sao Paulo (FMVZ/USP), SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia

    2017-02-15

    Elbow dysplasia disease includes an united anconeal process, fragmented medial coronoid process, osteochondrosis of humeral trochlea, articular incongruity and degenerative joint disease. The aim of this study was to present detailed morphologic and morphometric aspects of the elbow joint in dog in clinical and correlate with radiographic and tomographic (CT) exam. Inter-observer variation for articular incongruity measurements by CT, comparative analysis in the radiographic exam, angle in ulnar notch and its comparative analysis between radiographic and tomographic agreement examination in 44 elbow of dogs with different ages were evaluated. The statistics analyses included the kappa coefficient and interclass correlation and Fischer's test and McNemar's test. It was evidenced that individual performance of each radiographic incidence had poor agreement with the tomographic exam, suggesting that the accomplishment of more than two radiograph views are needed. There was no agreement between the three evaluators in the ulnar notch angle at radiographic and tomographic exams. However, there was good/moderate agreement for articular incongruity measurement in the sagittal plane between evaluators. It was possible to conclude that none of the five radiographic incidences was better than the others for radiographic analysis because each incidence had a better identification of a particular elbow compartment; measurements at the tomographic exam to evaluate radioulnar incongruity had no reproductiveness in the frontal plane, but in sagittal plan had a good/moderate agreement between observers and the angle in ulnar notch presented no repeatability at radiographic exam and no reproductiveness at tomographic exam. (author)

  19. Evaluation of impact strength of polyamide 6/bentonite clay nanocomposites; Avaliacao da resistencia mecanica sob impacto de nanocompositos de poliamida 6/argila bentonitica

    Energy Technology Data Exchange (ETDEWEB)

    Paz, Rene A.; Leite, Amanda M.D.; Medeirosa, Vanessa da N., E-mail: rene@cct.ufcg.edu.b [Universidade Federal de Campina Grande (UFCG), PB (Brazil). Curso de Pos-Graduacao em Ciencia e Engenharia de Materiais; Araujo, Edcleide M.; Melo, Tomas J.A. [Universidade Federal de Campina Grande (UFCG), PB (Brazil). Dept. de Engenharia de Materiais; Pessan, Luiz A. [Universidade Federal de Sao Carlos (DEMa/UFSCAR), SP (Brazil). Dept. de Engenharia de Materiais

    2010-07-01

    Nanocomposites of polymer/clay have had much attention in recent years, particularly those developed with layered silicates due to the need of engineering materials more efficient than pure polymers for certain applications. The level of exfoliation of layered silicates in crystalline structure of polymer matrices has been studied and has been observed that they affect the crystalline behavior and the physical and mechanical properties. In this study, nanocomposites of polyamide 6 were obtained by the melt intercalation method, using a regional bentonite modified with a quaternary ammonium salt in an amount of 3% by weight. XRD results showed that incorporation of salt among the layers of clay, making it organophilic and obtaining exfoliated and/or partially exfoliated structures. The impact properties of the nanocomposites showed inferior in relation to pure polyamide, in other words, lost of toughness. (author)

  20. Assessment and epidemiology of Chagas' disease in patients treated in Araguaina - Tocantins; Avaliacao e epidemiologia da cardiopatia chagasica em pacientes atendidos em Araguaina - Tocantins

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Valeria Rita

    2010-07-01

    Chagas disease (AD) was described by Carlos Chagas in 1909. It is caused by a parasite T. cruzi, transmitted by bugs, by blood transfusion, vertical and orally. The DC has two phases: acute and chronic. The evolution to the cardiac form occurs in about 30% of chronic cases and is the largest cause of mortality in chronic Chagas disease. The aim of this study was to Chagas' disease in patients of Tocantins, compared with other heart patients and asymptomatic from the standpoint of non-invasive exams using radiant energies such as echocardiography and ECG and RX. The descriptive study included 80 patients, 20 chronic form of Chagas disease, 20 indeterminate, 20 with other heart diseases, and 20 controls. There was a prevalence of 9.5% of chagasic patients treated in outpatient cardiology at Araguaina Tocantins, and 7.3% in chronic and 2.21% in the indeterminate. Of the chronic patients in the study 50% had mega esophagus and megacolon 4 (20%). Most patients had no family history of AD, nor was a smoker or drinker. Major electrocardiographic abnormalities found refer to driving. The evaluation of ICT, the chronic chagasic showed that increased by 40% of patients, 40% had esophageal changes and 20% of patients had megacolon s. The echocardiogram was abnormal in 42%). 27% of patients had EF below 55% changed. Changes in segmental contractility and Asynchrony septum were found in 80% of chronic Chagas disease. In 80% of the patients was observed diastolic dysfunction. The valvular changes occurred in 75%. Electrocardiographic abnormalities occurred in 80% of patients with CCC, while the other heart had ECG changes. Arterial hypertension had an incidence of 45% in patients with CCC and 40% in FCI. The systolic and diastolic ventricular dysfunction was more prevalent in groups that had an abnormal ECG and arrhythmia. Observed that the group of chagasic decreased ejection fraction is correlated to a higher incidence of arrhythmias besides diastolic dysfunction and related increased atrio-left, ICT correlates with LV size and EF and LA. The abnormal ECG also are related to the dysfunction. (author)

  1. Assessment of natural radioactivity in wall paints of commercial use in Brazil; Avaliacao da radioatividade natural em tintas de uso comercial no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Leandro Milhomens da

    2016-11-01

    Natural radioactivity in soils, rocks and construction materials, due to {sup 40}K and the natural series of {sup 232}Th and {sup 2}'3{sup 8}U, is the main contribution to external exposure in mankind. In this work, activity concentrations of {sup 226}Ra ({sup 238}U series), {sup 232}Th and {sup 4}'0K were determined for 50 white latex wall paints samples, commercialized in Brazil, namely 15 Economic quality samples, 15 Standard quality samples and 20 Premium quality samples and for a single titanium dioxide sample. The samples were tightly sealed and stored for a minimum period of 30 days, to reach the radioactive secular equilibrium from {sup 238}U and {sup 232}Th series, then measured by high resolution gamma ray spectrometry. The activity concentration was determined using the weighted average concentrations of {sup 214}Pb and {sup 214}Bi for {sup 226}Ra and {sup 228}Ac, {sup 212}Pb and {sup 212}Bi for {sup 232}Th. The {sup 4}'0K activity concentration was determined by its single transition of 1460.8 keV. Self attenuation correction factors of the samples whose densities are higher than 1.0 g.cm{sup -3}, were determined and used to make the necessary corrections. The radiological indices radium equivalent activity (Ra{sub eq}), activity concentration index (I{sub γ}), internal exposure risk index (H{sub in}) and external exposure risk index (H{sub ex}) and also the absorbed dose rate (D) and annual effective dose (D{sub ef}) were calculated from the activity concentrations of {sup 226}Ra, {sup 232}Th and {sup 40}K. The activity concentration values for {sup 226}Ra ranged from under the minimum detectable activity to 38.7 Bq.kg{sup -1}, for {sup 232}Th from under the minimum detectable activity to 101.2 Bq.kg{sup -1} and for {sup 40}K from under the minimum detectable activity to 256 Bq.kg{sup -1}. Ra{sub eq} ranged from 1.41 Bq.kg{sup -1} to 203 Bq.kg{sup -1}, I{sub γ} ranged from 0.0047 to 0.720, H{sub in} from 0.0076 to 0.653 and H{sub ex} from 0.0038 to 0.549. The absorbed dose rate ranged from 0.170 nGy.h{sup -1} and 21.3 nGy.h{sup -1} and the annual effective dose ranged from 0.83 μSv and 104.2 μSv. The results show that the activity concentrations of the wall paints studied in this work are below the recommended limits by Hassan et al. for Ra{sub eq} (370 Bq.kg{sup -1}), by European Commission for I{sub γ} (limit of 2 for superficial materials) and by the Organisation for Economic Co-operation and Development for H{sub in} and H{sub ex} (both with limit of 1), for all the 50 samples, assuring the safety of these wall paints with respect to radiological protection. (author)

  2. Renewability emergy index calculation in the evaluation of the sustainability of a national economy; Calculo do indice de renovabillidade emergetica na avaliacao da sustentabilidade de uma economia nacional

    Energy Technology Data Exchange (ETDEWEB)

    Siche Jara, Raul Benito [Universidad Nacional de Trujillo, La Libertad (Peru). Fac. de Ciencias Agropecuarias. Escuela de Ingenieria Agroindustrial], e-mail: Siche.J.R@gmail.com; Ortega Rodriguez, Enrique [Universidade Estadual de Campinas (DEA/FEA/UNICAMP), SP (Brazil). Lab. de Engenharia Ecologica e Informatica Aplicada], e-mail: ortega@fea.unicamp.br

    2006-07-01

    In this study, the emergy methodology was used to analyze the sustainability of the Peruvian economic system. The resources (natural and not natural) and importations had been accounting in units of solar emergy using data of the Peruvian economy for the year 2004. Emergy is an energy measure based in the contribution of the resources and its influence, defined as the energy of a type required producing a flow or storage of another type. The focus of this study is the calculation of the emergy index call 'renewability' (REN), considered as a general measure of the ecological sustainability. In a long period, only systems or processes with high REN are sustainable. This index is calculated by the accounting of the resources renewed used in the economy in emergy units (2.17E+23 seJ) and divided by emergy total that enters to the economic system (6.93E+23 seJ), resulting a REN of 0.31. The renewable resources that use Peru almost represent 20% of the total of renewable resources available in the system. The great amount of renewable resources that Peru can potentially use was calculated in 11.44E+23 seJ, meaning that the system can be more sustainable if the economy is based on increasing the use of renewable resources and to diminish the use of non-renewable resources and imported resources. These data show that Peru has a relatively sustainable economy that can improve or get worse, depending of its politics in the use of resources. (author)

  3. Evaluation of effects of ionizing radiation on materials used in dental restorations;Avaliacao dos efeitos da radiacao ionizante em materiais utilizados em restauracoes dentarias

    Energy Technology Data Exchange (ETDEWEB)

    Maio, Mireia Florencio

    2009-07-01

    This work consisted of quantitative studies of the effects caused by ionizing radiation on materials used in dental restorations (Titanium, Amalgam, Resin Composite and Glass Ionomer) aiming the deleterious effects of radiotherapy when patients with tumors in head and neck, arising when the teeth are restored within in the field of radiation. Samples were submitted to X-ray beams of 6 MV from a linear accelerator, VARIAN 2100C model. The samples were analyzed by X-ray fluorescence techniques to compare the chemical composition before and after the irradiation. The sample were submitted to Geiger-Mueller detectors and the ionization chambers in order to verify any residual radiation in the samples. The samples were also analyzed by gamma spectrometry by a Germanium detector. These tests were performed to determine small changes in the composition in the samples due to the radiation interaction. The results of this study may encourage the development of new research for alternative materials in dental restorations that can contribute to improve the quality of life of those patients with tumors of the mouth. (author)

  4. Synthesis optimization of calcium aluminate cement phases for biomedical applications; Avaliacao da sintese das fases de cimento de aluminato de calcio

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, T.L.; Santos, G.L.; Oliveira, I.R. [Universidade do Vale do Paraiba (UNIVAP), Sao Jose dos Campos, SP (Brazil); Pandolfelli, V.C. [Universidade Federal de Sao Carlos (UFSCar), SP (Brazil)

    2011-07-01

    Calcium aluminate cement (CAC) has been studied as a potential material for applications in the areas of health such as, endodontics and bone reconstruction. These studies have been based on commercial products consisting of a mixture of phases. Improvements can be attained by investigating the synthesis routes of CAC aiming the proper balance between the phases and the control of impurities that may impair its performance for biomedical applications. Thus, the aim of this work was to study the CAC synthesis routes in the Al{sub 2}O{sub 3}-CaCO{sub 3} and Al{sub 2}O{sub 3}-CaO systems, as well as the phase characterization attained by means of X ray analysis. The Al{sub 2}O{sub 3}-CaO route enabled the production of the target phases (CA, CA{sub 2}, C{sub 3}A and C{sub 12}A{sub 7}) with a higher purity compared to the Al2O3-CaCO3 one. As a result the particular properties of these phases can be evaluated to define a more suitable composition that results in better properties for an endodontic cement and other applications. (author)

  5. Sintering evaluation of spinel MA nanostructured obtained via synthesis of combustion in solution; Avaliacao da sinterizacao de espinelio MA nanoestruturado obtido via combustao em solucao

    Energy Technology Data Exchange (ETDEWEB)

    Vitor, P.A.M.; Braganca, S.R.; Bergmann, C.P., E-mail: pedroaugusto89@hotmail.com [Universidade Federal do Rio Grande do Sul (LACER/UFRGS), Porto Alegre, RS (Brazil). Laboratorio de Materiais Ceramicos

    2016-07-01

    Specimens were shaped from powders of spinel MA (MgAl2O4) obtained via synthesis combustion in solution (SCS) from the trio chemical precursor aluminum nitrate, magnesium nitrate and sucrose in water, and then sintered at different temperatures between 1350 and 1650 ° C. Were evaluated the physical properties (density, porosity, water absorption and linear shrinkage), mechanical (flexural 4 points), and the microstructures (SEM) as a function of sintering temperature. The densification increased with growing the value of the sintering temperature, wherein the temperature to 1650 ° C had the highest flexural strength and higher elastic modulus: 51.33 (± 6.83) and 26.16 MPa (± 5.06) GPa respectively. The study confirmed the microstructure of the densification of the particles, confirming the purity and nature of nanometric powders obtained via the SCS. (author)

  6. Preliminary results of the evaluation of biomass use as energy sources; Resultados preliminares da avaliacao do uso de biomassas como fontes de energia

    Energy Technology Data Exchange (ETDEWEB)

    Rocha Ferreira, Leo da; Tourinho, Octavio A.F. [Instituto de Planejamento Economico e Social (IPES), Rio de Janeiro, RJ (Brazil). Inst. de Pesquisas

    1985-12-31

    This article discusses the preliminary results of the BIOMASSA model of IPEA with emphasis on three aspects: temporal and spatial crop mix patterns along the analysis horizon; evaluation of the social cost of alcohol fuel ; and the impact of alcohol production on the balance of payments. It concludes that the PROALCOOL increases domestic costs, but the impact on the balance of payments is positive and substantial. (author). 8 tabs

  7. Evaluation of the efficiency of injection of polyacrylamide in different reservoir-rock samples; Avaliacao da eficiencia de injecao de poliacrilamida em diferentes amostras de rocha-reservatorio

    Energy Technology Data Exchange (ETDEWEB)

    Marcelino, Cleuton P.; Valentim, Adriano C.M.; Medeiros, Ana Catarina R. de; Girao, Joaquim H.S.; Barcia, Rosangela B. [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil)

    2004-07-01

    Water soluble polymers have been used extensively in the petroleum recovery, due to their ability in increasing the viscosity of the injection water and to reduce water/oil mobility ratio and the water relative permeability in the reservoir. This reduction acts favorably as a secondary effect, and it reestablishes part of the pressure in the reservoir after the flow of the polymer, causing a correction of the injection profile in the wells through the restructuring of the resident fluids in the porous media. Nevertheless, some parameters influence the improve of this mechanism, such as petrophysics properties, chemical composition of the rock, adsorption, resistance factor and the residual resistance factor. Many paper in the area of polymers applied to the enhanced petroleum recovery indicate a high efficiency in the injection of different partially hydrolysed polyacrylamides, in different concentrations, or even in different injection conditions, as: temperature, flow, among others. In this work it was evaluated the behavior and efficiency of partially hydrolysed polyacrylamide flooding on outcrop cores from Botucatu, Rio Bonito, Clashach and Assu, using core flow tests and computer simulations. (author)

  8. Characterization and evaluation of residue 'grits' of the cellulose industry; Caracterizacao e avaliacao do resisduo 'grits' da industria de celulose

    Energy Technology Data Exchange (ETDEWEB)

    Destefani, A.Z.; Santos, M.M.; Holanda, J.N.F. [Universidade Estadual do Norte Fluminense Darcy Ribeiro (LAMAV/CCT/UENF), Campos dos Goytacazes, RJ (Brazil). Lab. de Materiais Avancados

    2010-07-01

    The cellulose industry generates huge amounts of solid waste residue called 'grits'. These wastes have been willing over time in landfills near the mills. However, this type of disposal is not environmentally friendly and can cause degradation and environmental pollution. In addition, environmental legislation increasingly severe and the high costs of landfill have led the search for new alternatives for final disposition of this abundant waste. In this context, this study is to characterize waste grits, generated by the cellulose industry in the region of Aracruz-ES. The residue samples were characterized in terms of chemical composition, X-ray diffraction, particle size distribution and thermal analysis (DTA and TGA). The characterization of the residual 'grits' demonstrated its potential as a feedstock for production of soil-cement bricks. (author)

  9. Evaluation of bioactivity in vitro of endodontic calcium aluminate cement; Avaliacao da bioatividade in vitro de cimento endodontico a base de aluminato de calcio

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, I.R.; Andrade, T.L.; Santos, G.L., E-mail: ivonero@univap.br [Universidade do Vale do Paraiba (UNIVAP), Sao Jose dos Campos, SP (Brazil); Pandolfelli, V.C. [Universidade Federal de Sao Carlos (UFSCar), SP (Brazil)

    2011-07-01

    Bioactivity is referred to as the capacity of a material to develop a stable bond with living tissue via the deposition of hydroxyapatite. Materials which exhibit this property can be used to repair diseased or damaged bone tissue and can be designed to remain in situ indefinitely. An indication of bioactivity can be obtained by the formation of a hydroxyapatite layer on the surface of a substrate in simulated body fluids (SBF) in vitro. Therefore, set samples of calcium aluminate endodontic cement were maintained in contact with SBF solutions (Kokubo and Rigo) and their surfaces were later evaluated by means of SEM, EDX and DRX. Measurements of pH and ionic conductivity were also carried out for SBF solutions in contact with set samples of endodontic cement. The ideal conditions of precipitation were obtained in SBF Rigo been observed a surface layer with spherical morphology characteristic of stoichiometric hydroxyapatite.(author)

  10. Evaluation of the inflammatory activity in chronic osteomyelitis. Contribution of the scintigraphy with polyclonal antibodies; Avaliacao de atividade inflamatoria em osteomielite cronica. Contribuicao da cintilografia com anticorpos policlonais

    Energy Technology Data Exchange (ETDEWEB)

    Sapienza, Marcelo Tatit

    1996-07-01

    Active chronic osteomyelitis or complicating osteomyelitis (superimposed on diseases that changes the normal bone structure fractures, post-surgery, prosthesis) can be difficult to diagnose by anatomic radiological imaging modalities, like plain radiograph and CT. These diseases frequently cause also increased bone remodeling, leading to nonspecific uptake of Tc-99m-bone scan agents and gallium-67. New radiopharmaceuticals with greater inflammation/infection avidity and specificity are being developed, including the nonspecific polyclonal immunoglobulin (IgG) labeled with technetium-99. Tc-99m-IgG may be available as a ready to use kit, with no reported side effects, low patient absorbed radiation dose and low cost. The mechanism of IgG uptake at the inflammation site has not been fully elucidated yet. Specific (receptor linking, physico-chemical immunoglobulin properties) and nonspecific mechanisms (enhanced vascular permeability and macromolecular exudate) has been suggested. IgG scintigraphy results are affected by the isotope, labeling procedure adopted and characteristics of the inflammatory focus. Nineteen patients with suspected osteomyelitis (active chronic osteomyelitis or violated bone osteomyelitis) were studied by Tc-99m-IgG scintigraphy (directly labeled polyclonal immunoglobulin, Sandoglobuilina - Sandoz). All patients also underwent standard three-phase bone scintigraphy using methylene diphosphonate (Tc-99m-MDP), gallium-67 scintigraphy and plain radiographs. Infection was found in 8 sites. Sensitivity and specificity for Tc-99m-MDP, gallium-67 and Tc 99m-IgG scintigraphy were, respectively, 88 and 36%, 75 and 73%,88 and 82%. All patients with false positive IgG scintigraphies had previous surgery. Other current scintigraphic procedures used in the diagnosis of osteomyelitis are also reviewed. (author)

  11. Evaluation of maximum absorbed dose for accompanying patients in nuclear medicine establishments; Avaliacao da dose maxima absorvida por acompanhantes de pacientes em servicos de medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Cabral, Geovanna; Amaral, Ademir; Hazin, Clivis A. [Pernambuco Univ., Recife, PE (Brazil). Dept. de Energia Nuclear; Lima, Ricardo A.; Nogueira, Maria S. [Centro Regional de Ciencias Nucleares (CRCN), Recife, PE (Brazil); Lopes, Ferdinand [Centro de Medicina Nuclear de Pernambuco (CEMUPE), Recife, PE (Brazil); Guimaraes, Maria Ines C.C. [Sao Paulo Univ., SP (Brazil). Centro de Medicina Nuclear

    2001-07-01

    In nuclear medicine, radioisotopes are bound to various pharmaceuticals for use in diagnostic and therapeutic applications. These unsealed sources are administered in various forms to patients, who remain radioactive for hours or days, and represent a source of potential radiation exposure for others. Thus, in nuclear medicine departments, radiation protection of workers and members of the public (especially persons accompanying patients) must consider this exposure. In this study, thermoluminescent dosimeters were given to various persons who were accompanying patients in two nuclear medicine departments in Recife, Pernambuco State, Brazil. Exposure results are given, and issues regarding exposure conditions and times for members of the public in these departments are discussed. (author)

  12. Powder addition assessment of manganese residue ceramic matrix coating; Avaliacao da adicao do po de residuo de manganes em matriz ceramica para revestimento

    Energy Technology Data Exchange (ETDEWEB)

    Conceicao, A.C.R. da; Santos, O.C.; Leao, M.A., E-mail: arangel-ma@hotmail.com [Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia (IFBA), BA (Brazil)

    2016-07-01

    The use of recycled materials in the composition of new products follows the production's worldwide trending, meeting new technological requirements and environmental concerns. This work aims to utilize the residue of manganese dust on ceramic mass for the production of ceramic coating. The raw materials were characterized by both x-ray fluorescence and diffraction. The powder residue added to clay in the percentage of 0%, 5%, 10% and 15% (measured in weight) was compressed by a uniaxial pressing of 30MPa and the sintering temperatures were 900°, 1000° and 1100°. The samples were analysed in relation to flexural strength, bulk density, water absorption and linear shrinkage. The microstructural variation was also analysed by x-ray diffraction and electron microscopy. The results showed that there is a viability for the production of porcelain ceramic coating (A3 and A4 formulations) and stoneware (A2 formulation) according to the specification of technical standards. author)

  13. Magnetic resonance imaging textural evaluation of posterior cranial fossa tumors in childhood; Avaliacao textural por ressonancia magnetica dos tumores da fossa posterior em criancas

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Joelson Alves dos; Costa, Maria Olivia Rodrigues da; Otaduy, Maria Concepcion Garcia; Lacerda, Maria Teresa Carvalho de; Leite, Claudia da Costa [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Dept. de Radiologia]. E-mail: joelson_alves@ig.com.br; Matsushita, Hamilton [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Dept. de Neurologia

    2004-08-01

    Objective: To distinguish healthy from pathological tissues in pediatric patients with posterior cranial fossa tumors using calculated textural parameters from magnetic resonance images. Materials And Methods: We evaluated 14 pediatric patients with posterior cranial fossa tumors using the software MaZda to define the texture parameters in selected regions of interest representing healthy and pathological tissues based on T2-weighted magnetic resonance images. Results: There was a statistically significant difference between normal and tumoral tissues as well as between supposedly normal tissues adjacent and distant from the tumoral lesion. Conclusion: Magnetic resonance textural evaluation is an useful tool for determining differences among various tissues, including tissues that appear apparently normal on visual analysis. (author)

  14. Evaluation of poly(vinylpyrrolidone) and collagen by Low Field Nuclear Magnetic Resonance Spectroscopy; Avaliacao da polivinilpirrolidona e do colageno por ressonancia magnetica nuclear de baixo campo

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Paula de M.; Tavares, Maria I.B. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Inst. de Macromoleculas Professora Eloisa Mano]. E-mail: pmcosta@ima.ufrj.br

    2005-07-01

    Blends of natural and synthetic polymers represent a new class of materials with better mechanical properties and biocompatibility than those of the single components. Collagen and poly(vinylpyrrolidone) are well known for their important biological properties. The blending of collagen with poly(vinylpyrrolidone) makes it possible to obtain new materials in which strong interactions between the synthetic and biological components occur. Do to the excellent biocompatibility of these polymers, this blend has been much studied intending biomedical applications. And a one technique that can provide important information on molecular mobility, compatibility and even evaluate the interactions that can occur with these polymers is the Low Field Nuclear Magnetic Resonance Spectroscopy. Thus, the purpose of this work is to evaluate collagen and poly(vinylpyrrolidone) by Low Field Nuclear Magnetic Resonance Spectroscopy. From the values of relaxation times obtained, we can conclude that these materials have different interactions, and different mobility domains, confirming the heterogeneity and complexity of these materials. (author)

  15. Chemical and microbiological assessments of the multi mixture treated by gamma radiation; Avaliacao quimica e microbiologica da multimistura tratada por irradiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Cinthia Graciele

    2008-07-01

    In Brazil, the multi mixture have being used since the eighties as an alternative against severe infantile malnutrition of the poorest population. However, its use is still reason of controversies mainly due to: the presence of anti nutritional factors, the microbiological quality and the nutritional value. Considering the routine use of multi mixture in the region, this work aimed to evaluate samples of multi mixture were collected in the metropolitan area of the City of Belo Horizonte/MG for determining the anti nutritional factors (phytic and oxalic acids), the microbiological quality, the centesimal and mineral composition, and still the induced effect in these factors of the gamma radiation. For the analyses, the samples passed by the process of gamma irradiation at doses of: 2, 4, 6, 8 and 10 kGy and then were evaluated anti nutritional factors (phytic acid and oxalic), the microbiological quality (yeasts and molds, Salmonella, Coagulase positive Staphylococcus, Bacillus cereus, coliform to 45 deg C) to full percentage (moisture, ash, proteins, carbohydrates and lipids) and the efficiency of the method of Paramagnetic Electronic Resonance (EPR) in the detection of irradiated samples. The mineral composition of the samples was carried out by the irradiation by Neutronic Activation. The methods used were searched in literature. The obtained results suggest that the concentration of the phytic and oxalic acids can not be appropriated for the children with severe nutritional deficit and that it would be necessary additional control in their daily ingestion due to the absorption of essential minerals. In general the samples had presented acceptable microbiological quality for consumption, except by one of it. The data of the centesimal and mineral composition, in the usually recommended portions, showed lower concentration than recommended for children. Any significant alteration in phytic and oxalic acids as well as in the centesimal composition were detected after gamma irradiation. The electronic paramagnetic resonance can be detected irradiated samples. (author)

  16. Evaluation of absorbed radiation dose in mammography using Monte Carlo simulation; Avaliacao da dose absorvida em mamografia usando simulacao Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Bruno L.; Tomal, Alessandra [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil). Instituto de Fisica Gleb Wataghin

    2016-07-01

    Mammography is the main tool for breast cancer diagnosis, and it is based on the use of X-rays to obtain images. However, the glandular tissue present within the breast is highly sensitive to ionizing radiation, and therefore requires strict quality control in order to minimize the absorbed dose. The quantification of the absorbed dose in the breast tissue can be done by using Monte Carlo simulation, which allows a detailed study of the deposition of energy in different regions of the breast. Besides, the results obtained from the simulation can be associated with experimental data and provide values of dose interest, such as the dose deposited in glandular tissue. (author)

  17. Exergy and thermoeconomic evaluation of hydrogen production from natural gas; Avaliacao exergetica e termo-economica da producao de hidrogenio a partir do gas natural

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, Flavio Eduardo da [PROMON Engenharia Ltda., Sao Paulo, SP (Brazil); Oliveira Junior, Silvio de [Universidade de Sao Paulo (USP), SP (Brazil). Escola Politecnica

    2008-07-01

    Some specific processes are required to obtain pure hydrogen and the most usual one is the natural gas reforming, where natural gas reacts with superheated steam producing H{sub 2}, CO, CO{sub 2} and H{sub 2}O. This paper presents exergy and thermoeconomic analysis of a complete hydrogen production unit of a petroleum refinery. The hydrogen production unit analysed in this paper has to supply 550,000 Nm{sup 3} of hydrogen per day to purify diesel oil. Based on a synthesis plant of the hydrogen production unit, the exergy efficiency of each component and of the overall plant are calculated. The hydrogen production cost is determined by means of a thermoeconomic analysis in which the equality cost partition method is employed, including capital and operational costs, in order to determine the production cost of hydrogen and other products of the plant.(author)

  18. Evaluation of homogeneity and dose conformity in IMRT planning in prostate radiotherapy; Avaliacao da homogeneidade e conformidade de dose em planejamentos de IMRT de prostata em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Juliane S.; Leidens, Matheus; Estacio, Daniela R., E-mail: juliane.lopes@pucrs.br [Hospital Sao Lucas (PUC-RS), Porto Alegre, RS (Brazil). Servico de Radioterapia; Razera, Ricardo A.Z.; Streck, Elaine E.; Silva, Ana M.M. da [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil). Faculdade de Fisica

    2015-12-15

    The goal of this study was to evaluate the dose distribution homogeneity and conformity of radiation therapy plans of prostate cancer using IMRT. Data from 34 treatment plans of Hospital Sao Lucas of PUCRS, where those plans were executed, were retrospectively analyzed. All of them were done with 6MV X-rays from a linear accelerator CLINAC IX, and the prescription doses varied between 60 and 74 Gy. Analyses showing the homogeneity and conformity indices for the dose distribution of those plans were made. During these analyses, some comparisons with the traditional radiation therapy planning technic, the 3D-CRT, were discussed. The results showed that there is no correlation between the prescribed dose and the homogeneity and conformity indices, indicating that IMRT works very well even for higher doses. Furthermore, a comparison between the results obtained and the recommendations of ICRU 83 was carried out. It has also been observed that the indices were really close to the ideal values. 82.4% of the cases showed a difference below 5% of the ideal value for the index of conformity, and 88.2% showed a difference below 10% for the homogeneity index. Concluding, it is possible to confirm the quality of the analyzed radiation therapy plans of prostate cancer using IMRT. (author)

  19. Importance of evaluation of uncertainties on the measurement of natural gas and petroleum volumes; Importancia da avaliacao das incertezas na medicao dos volumes de petroleo e gas natural

    Energy Technology Data Exchange (ETDEWEB)

    Silva Filho, Jose Alberto Pinheiro da; Oliveira, Thiago Barra Vidal de; Mata, Josaphat Dias da [PETROBRAS, Rio de Janeiro, RJ (Brazil)], Emails: jose.pinheiro@petrobras.com.br, thiagovidal@petrobras.com.br, josaphat@petrobras.com.br; Val, Luiz Gustavo do [Instituto de Qualidade e Metrologia (IQM), Rio de Janeiro, RJ (Brazil)], E-mail: gdoval.iqm@petrobras.com.br

    2009-07-01

    The measurement is considered as the 'cash register' of the enterprises, increasing the accuracy and the exigence at each step when come close to the delivery points, where the 0.1 % of differences are discussed. The work presents the approach used in the evaluation of measurement uncertainties in the volumes obtained of petroleum and natural gas at the processes of production in Brazil, and in the international level as well.

  20. Residual stress evaluation and curvature behavior of aluminium 7050 peen forming processed; Avaliacao da tensao residual em aluminio 7050 conformado pelo processo peen forming

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, R.R. de; Lima, N.B., E-mail: rolivier@ipen.b, E-mail: nblima@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Braga, A.P.V.; Goncalves, M., E-mail: anapaola@ipt.b, E-mail: mgoncalves@ipt.b [Instituto de Pesquisas Tecnologicas (IPT), Sao Paulo, SP (Brazil)

    2010-07-01

    Shot peening is a superficial cold work process used to increase the fatigue life evaluated by residual stress measurements. The peen forming process is a variant of the shot peening process, where a curvature in the plate is obtained by the compression of the grains near to the surface. In this paper, the influence of the parameters such as: pressure of shot, ball shot size and thickness of aluminum 7050 samples with respect to residual stress profile and resulting arc height was studied. The evaluation of the residual stress profile was obtained by sin{sup 2} {Psi} method. (author)

  1. Evaluation of the optical quality of compound parabolic concentrator solar collectors; Avaliacao da qualidade otica de coletores solares concentradores parabolicos compostos

    Energy Technology Data Exchange (ETDEWEB)

    Beyer, P.O.; Krenzinger, A. [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Programa de Pos-graduacao em Engenharia Mecanica

    1990-12-31

    This work presents a simulation of solar compound parabolic concentrators using the ray tracing technique. The program can be used as a computer aided design and quality control applications for parabolic mirrors. (author). 4 refs., 8 figs.

  2. Evaluation of operational management in the oil terminals using human factor indicator; Avaliacao da gestao operacional em terminais com o uso do indicador de fator humano

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, George L.D. [PETROBRAS, Rio de Janeiro, RJ (Brazil); Lima, Gilson Brito Alves [Universidade Federal Fluminense, Niteroi, RJ (Brazil). LATEC. Mestrado Profissional em Sistemas de Gestao

    2005-07-01

    This research has as objective to analyze the continuous improvement in a management system at TRANSPETRO in Madre de Deus Terminal (BA), environment and occupational health, particularly in the reduction of the accident levels. We consider relevant in this research the effective implementation of the human factor that includes the boarding of the work system relating them it three points: individual activities, organizational processes of work and activities, emphasizing the management of these resources and the communication between them. The case study it was make in a company of logistic of fuels. The methodology was lead through bibliographical research and applied closed questionnaire (adaptation's baseline API 770 - Manager's Guide to Reducing Human Errors Improving - Improving in the Process Industries) in 2003 and 2005 with the manager, coordinators, supervisors, operators and others technician. Were analyzed results of the company in management security and occupational health, such as: pointers of the tax of frequency of accidents with and without removal, volume of leaked product and results of internal and external audits. We conclude that the importance of the human factor in the Safety Management that propitiated significant progress in the organization during the development of the research. (author)

  3. Dose evaluation in medical staff during diagnostics procedures in interventional radiology; Avaliacao da dose na equipe medica durante procedimentos diagnoticos de radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Bacchim Neto, Fernando A.; Alves, Allan F.F.; Rosa, Maria E.D.; Miranda, Jose R.A. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Instituto de Biociencias. Departamento de Fisica e Biofisica; Moura, Regina [Faculdade de Medicina de Botucatu, SP (Brazil). Departamento de Cirurgia e Ortopedia; Pina, Diana R., E-mail: bacchim@ibb.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina. Departamento de Doencas Tropicais e Diagnostico por Imagem

    2014-08-15

    Studies show that personal dosimeters may underestimate the dose values in interventional physicians, especially in extremities and crystalline. The objective of this work was to study the radiation exposure levels of medical staff in diagnostic interventional radiology procedures. For this purpose LiF:Mg,Ti (TLD-100) dosimeters were placed in different regions of the physician body. When comparing with reference dose levels, the maximum numbers of annual procedures were found. This information is essential to ensure the radiological protection of those professionals. (author)

  4. Evaluation of quality control tools for patients submitted to IMRT; Avaliacao das ferramentas de controle da qualidade para pacientes submetidos ao IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Lavor, Milton; Rodrigues, Laura N.; Silva, Marco A., E-mail: miltonlavor@gmail.com [Universidade de Sao Paulo (HCFMRP/USP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Servico de Radioterapia

    2013-04-15

    Intensity modulated radiation therapy (IMRT) is currently being implemented in a rapidly growing number of centers in Brazil. As consequence many institutions are now facing the problem of performing a comprehensive quality control program before and during the implementation of IMRT in the clinical practice. This paper proposes a methodology for quality control and presents the results and evaluations of the data obtained from the proposed methodology. Ionization chamber and two-dimensional array detector were performed in IMRT treatment planning in order to assess the absolute value of the total dose of all fields. The relative total dose distribution of all fields was measured with a radiochromic film and a two-dimensional array in a phantom. A comparison between measured and calculated dose distributions was performed using the gamma-index method, assessing the percentage of points that meet the criteria of ±3% dose difference and ±3mm distance to agreement. As a result and review of 113 tested IMRT beams using ionization chamber and 81 using two-dimensional array, the proposal was to take an action level of about ±5% compared to the treatment planning systems and measurements, for the verification of the dose in a single point at the low gradient dose region. Analysis of the two-dimensional array measurements showed that the gamma value was <1 for 97.7% of the data and for the film the gamma value was <1 for 96.6% of the data. This work can establish action levels required for quality control program proposed and implemented in the Department of Radiotherapy - Hospital das Clinicas in Sao Paulo that allows an accurate delivery of dose in 'sliding-window' IMRT with micro multi leaf collimator. (author)

  5. Methodology for probability of failure assessment of offshore pipelines; Metodologia qualitativa de avaliacao da probabilidade de falha de dutos rigidos submarinos estaticos

    Energy Technology Data Exchange (ETDEWEB)

    Pezzi Filho, Mario [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2005-07-01

    In this study it is presented a methodology for assessing the likelihood of failure for every failure mechanism defined for carbon steel static offshore pipelines. This methodology is aimed to comply with the Integrity Management policy established by the Company. Decision trees are used for the development of the methodology and the evaluation of the extent and the significance of these failure mechanisms. Decision trees enable also the visualization of the logical structure of algorithms which eventually will be used in risk assessment software. The benefits of the proposed methodology are presented and it is recommended that it be tested on static offshore pipelines installed in different assets for validation. (author)

  6. Evaluation of absorbed radiation dose rate in a didactic X-ray equipment; Avaliacao da taxa de dose absorvida em um equipamento de raios-X didatico

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Phelipe Amaral Ferreira; Perini, Ana Paula; Neves, Lucio Pereira, E-mail: lucio.neves@ufu.br [Universidade Federal de Uberlandia (UFU), MG (Brazil). Instituto de Fisica

    2016-07-01

    This work was performed in order to create a new didactic experiment in the X-ray apparatus of PHYWE, where the saturation current was obtained through a free air ionization chamber. The values of saturation currents were obtained in two ways. Initially, the anodic DDP was kept constant and the anodic current was varied. In the second way, the anodic current was kept constant while the anodic DDP was varied. Therefore, we were able to evaluate the dependence of the absolved dose rate in relation to the DDP and the tube current. (author)

  7. Kerma rate evaluation in the air in a room interventional cardiology; Avaliacao da taxa de Kerma no ar em uma sala de cardiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Real, Jessica V.; Luz, Renata M. da, E-mail: jessica.real@pucrs.br, E-mail: renata.luz@pucrs.br [Hospital Sao Lucas (HSL/PUCRS), Porto Alegre, RS (Brazil); Fröhlich, Bruna D.; Silva, Ana Maria Marques da, E-mail: bruna.frohlich@acad.pucrs.br, E-mail: ana.marques@pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUCRS), Porto Alegre, RS (Brazil)

    2014-07-01

    In recent years, the number of interventional cardiology procedures is increasing. However, due to the long time of fluoroscopy in these procedures, care teams can receive high doses of radiation. The radiation scattered by the patient is not uniform, and their assessment is of utmost importance. This study aimed to estimate and map the kerma rate in the air at the time of the gonads, in an interventional cardiology room, seeking to optimize the dose absorbed by individuals occupationally exposed to ionizing radiation. For data collection, the room was divided into quadrants of 1m{sup 2}, totaling 40 collection points. The simulator was positioned so that its entry surface was located in the interventional reference point. Were chosen the conditions that simulate angiography and angioplasty procedures performed in the service. The data were obtained for height of 1 meter, gonad region. The results obtained for kerma rates in air, in quadrants, show that higher measured values was in the vicinity of the X-ray tube. Has been found that the medical staff are more exposed, because of its location during the procedure, around the table. The law of the inverse square distance of the farthest points of the X-ray tube were verified.

  8. Evaluation of the capacity of heavy metal adsorption in exfoliated vermiculite; Avaliacao da capacidade de adsorcao de metal pesado em vermiculitas esfoliadas

    Energy Technology Data Exchange (ETDEWEB)

    Lima, J.F.; Silva, P.S.; Hanken, R.B.L. [Universidade Federal de Campina Grande (UAEMa/UFCG), PB (Brazil). Unidade Academica de Engenharia de Materiais; Raposo, C.M.O., E-mail: raposo@dmg.ufcg.edu.b [Universidade Federal de Campina Grande (UAMG/UFCG), Bodocongo, PB (Brazil). Unidade Academica de Mineracao e Geologia

    2009-07-01

    Many groups from modern society have seen with attention the issues of pollutants, generally present in nature, those same that have caused irreversible damages to the environment. The Vermiculite, a phyllosilicate, with t-o-t structure, have high interlamelar charge, has been studied as cationic exchanger, whose application when exfoliated, are increased. This work has the objective of evaluate the absorption capacity of chromium (III), in different concentrations, in high, slim and medium concentrations of exfoliated vermiculites. The results obtained from the characterization by spectroscopy in infrared and by diffraction of x-ray from prepared solids showed important variations in the quantity of adsorbed metal in order the size of the concentrated particles. (author)

  9. Method for evaluating the applicability and application rate wastes in soil; Metodo para avaliacao da aplicabilidade e taxa de aplicacao de residuos em solo

    Energy Technology Data Exchange (ETDEWEB)

    Linhares, Monica Moreira [Partime (Brazil); Seabra, Paulo Negrais [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    1991-01-01

    Land treatment of refinery solid wastes has been practiced in the last few years by some PETROBRAS refineries. The biodegradation process is dynamic and complex, and incorrect monitoring may destroy the potential of the soil. Due to great differences both in terms of soils and of residues, each case must be monitored individually. We therefore developed a monitoring method for land farming systems based on the impact of the waste on indigenous soil microbial populations. The method is extremely simple, requiring only a gas chromatograph to evaluate the CO{sub 2} evolution, and can detect possible causes for low efficiency biodegradation processes. Conditions should then be altered, to ensure adequate functioning of the system.The method also allows for determination of the applicability of candidate wastes and of acceptable waste application rates in soil. (author) 2 refs., 7 figs.

  10. Evaluation of the life cycle of integrated production of ethanol and biodiesel; Avaliacao do ciclo de vida da producao integrada de etanol e biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Simone Pereira de [Universidade Estadual de Campinas (UNICAMP), SP (Brazil)], email: sp.souza@yahoo.com.br; Pacca; Sergio Almeida [Universidade de Sao Paulo (USP), SP (Brazil). Escola de Artes, Ciencias e Humanidades], email: spacca@usp.br

    2010-07-01

    Sugarcane and palm are amongst the crops with the highest yields, which can reach 6 to 7.5 thousand liters of ethanol per hectare year and 4 to 6 metric tons of oil per hectare year, respectively. A joint production of biofuels from these crops is an interesting alternative for life cycle assessment improvement through fossil fuel and greenhouse gas emissions reduction, besides energy efficiency gains. The objective of this work is comparing the Brazilian production system sugarcane ethanol with an integrated system proposal where the ethanol and palm biodiesel are produced together. This comparative study is based on a life cycle approach using the ISO 14.044/2006 and appropriate indicators. Production systems in Cerrado, Cerradao and grassland ecosystem were considered. The energy balance, carbon balance and land use change were evaluated. The integrated system includes a 100% substitution of biodiesel by diesel, which is used in life cycle agriculture stages. Distinct fractions of sugarcane used for sugar production were assessed. When all sugarcane is sent to sugar production, ethanol is produced by molasses. The data were collected by direct observation method by questionnaire and secondary sources. Three sugarcane mills situated in Sao Paulo state and a palm mill located in Para state were surveyed. Results showed a 164% increase in energy balance for the joint production system in comparison to the traditional system. Besides this, the joint production system demonstrated a 24% GHG emission reduction. For ethanol production by molasses, the energy balance was up to 59% and 162% higher in scenarios 1 and 2, respectively, which differ each other through of the boiler that was utilized. For GHG emission, the reduction can reach 91%. The land use change identify an average ecosystem carbon payback time for Cerrado, Cerradao and Degraded Grassland of 5, 10, and -5 years, respectively. In conclusion, the joint production system of sugarcane ethanol and palm biodiesel presents an improvement in energy balance, GHG emissions and land use change impacts in comparison to the traditional ethanol system. (author)

  11. Chemical constituents and evaluation of antibacterial activity of Macroptilium lathyroides (L.) Urb. (Fabaceae); Constituintes quimicos e avaliacao da atividade antibacteriana de Macroptilium lathyroides (L.) Urb. (Fabaceae)

    Energy Technology Data Exchange (ETDEWEB)

    Sousa, Leoncio M. de; Gois, Roberto W. da S.; Lemos, Telma L. G.; Arriaga, Angela M. C.; Andrade-Neto, Manoel [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Departamento de Quimica Organica; Santiago, Gilvandete M.P., E-mail: gil@ufc.br [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Departamento de Farmacia; Braz-Filho, Raimundo [Universidade Estadual do Norte Fluminense (UENF), Campos dos Goytacazes, RJ (Brazil). Centro de Ciencias e Tecnologias; Costa, Jose G.M. da; Rodrigues, Fabiola F.G. [Universidade Regional do Cariri, Crato, CE (Brazil). Departamento de Quimica Biologica

    2013-11-01

    The chemical investigation of the stems and branches of Macroptilium lathyroides led to the isolation of a mixture of {beta}-sitosterol and stigmasterol. The extracts from the roots allowed the isolation of lasiodiplodin, a mixture of stigmast-4-en-6{beta}-ol-3-one and stigmast-4,22-dien-6{beta}-ol-3-one, de-O-methyllasiodiplodin, genistein and lupinalbin A. The structures of the isolated compounds were assigned on the basis of their NMR data, including comparison of their spectral data with values described in the literature. The antibacterial activity of crude extracts from stems, branches and roots was evaluated. This is the first report involving the chemical investigation of this species. (author)

  12. Biodegradation evaluation of recycled polyethylene doped with Moringa oleifera oil; Avaliacao da biodegradacao de filmes de polietileno reciclado dopados com oleo de Moringa oleifera

    Energy Technology Data Exchange (ETDEWEB)

    Bicalho, Luciana A.; Novack, Katia M.; Melo, Tania M.S., E-mail: knovack@iceb.ufop.br [Dept. de Quimica (DEQUI) - Universidade Federal de Ouro Preto (UFOP), Ouro Preto, MG (Brazil)

    2011-07-01

    Chemical modifications and use of additives are some of the mainly ways to obtain polymer materials with especial properties. Vegetable oils incorporated to polymers preserve their structure while make possible a reduction of degradation rate. This work proposed the use of polyethylene, one of the most common polymer commodities, because of its low cost and wide application. In this project it was verified the possibility of making polymer materials with properties of a natural product through the incorporation of Moringa oleifera oil to recycled low density polyethylene (LDPEr) in different proportions. The films were buried for different times and their degradation was evaluated.) Samples were characterized by DSC, TGA and XRD. It was observed that samples doped with Moringa oil showed lower degradation time. (author)

  13. Evaluation of radiation effects on dental enamel hardness and dental restorative materials; Avaliacao do efeito da irradiacao na dureza do esmalte dental e de materiais odontologicos

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Lena Katekawa; Saiki, Mitiko [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Supervisao de Radioquimica; Campos, Tomie Nakakuki [Sao Paulo Univ., SP (Brazil). Faculdade de Odontologia. Dept. de Protese

    2000-07-01

    This research presents the results of the microhardness of human dental enamel and of the following dental restorative materials: three dental porcelains - Ceramco II, Finesse and Noritake, and two resin restorative materials - Artglass and Targis, for materials submitted to different times of irradiation at the IEA-R1m nuclear reactor under a thermal neutron flux of 10{sup 12}n cm{sup -2}.s{sup -1} . The results obtained indicated that there is a decrease of the surface microhardness when the enamel is irradiated for 1 h and when dental materials are irradiated for 3 h. However, enamels irradiated for 30 min. did not show significant change of their surface hardness. Therefore, the selection of irradiation time is an important factor to be considered when irradiated teeth or dental materials are used in the investigations of their properties. (author)

  14. Technological evaluation of fuel cells using natural gas for distributed power generation; Avaliacao tecnologica da utilizacao de gas natural em celulas a combustivel para geracao distribuida de energia

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Mauricio O. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE). Programa de Engenharia Mecanica; Giannini, Marcio P.; Arouca, Mauricio C. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE). Programa de Planejamento Energetico

    2004-07-01

    The search for sustainable and more rational means of power generation motivates the scientific crew to search for more efficient and cleaner systems. Oil dependence becomes from the kind of development that the humanity had and cannot be dismissed. The question is how to use this source in a more intelligent way. Fuel Cells are electrochemical devices that convert into electric energy the chemical energy from oxi-reduction reactions between a fuel and an oxidant. The current fuel used in a Fuel Cell is hydrogen and oxygen is the oxidant. The great advantage of this device is its efficiency, higher than the one achieved with internal combustion engines. Also Fuel Cells are not limited by Carnot's efficiency. This paper is about the implementation of a distributed generation system using Fuel Cells. Technical aspects are approached together with economical and environmental needs. The already existence of Gas pipelines and the grown production of Natural Gas presented by Brazil turns it into a good market for the implementation of this energy source. The evaluation of this paper shows that is technically possible to use NG in Fuel Cells, mostly in South and Southeast regions, applying the distributed generation of energy concept. The most interesting in a strategic manner is that Brazil already have an indication that it's capable of developing this technology, opening a new market tuning with world's new technological developments. Many research centers develop this technology, not only from the cell composition itself, but also manufacturing techniques. (author)

  15. Evaluation of thermal stability of paraffin wax by differential scanning calorimetry; Avaliacao da estabilidade termica de parafina por calorimetria diferencial de varredura

    Energy Technology Data Exchange (ETDEWEB)

    Godinho, K.O.; Silva, A.G.P.; Holanda, J.N.F. [Universidade Estadual do Norte Fluminense (LAMAV/UENF), Campos dos Goytacazes, RJ (Brazil). Grupo de Materiais Ceramicos], Email: holanda@uenf.br

    2010-07-01

    Phase change materials for heat storage are used as passive solar energy storage materials, which can be impregnated into construction materials. In this work the thermal stability (heating/cooling cycle) of the paraffin wax was investigated using differential scanning calorimetry. The latent heat and fusion temperature were determined for the following thermal cycles: 0, 30, 180 and 360. The thermal stability for paraffin wax infiltrated in support of gypsum was also determined. The experimental results showed that the paraffin wax showed good thermal stability in the states pure and infiltrated for up to 360 thermal cycles. (author)

  16. Evaluation of influence of fertilizers in radium concentration from tomato culture; Avaliacao da influencia dos fertilizantes nos teores de radio encontrados na cultura do tomate

    Energy Technology Data Exchange (ETDEWEB)

    Lauria, Dejanira C. [Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, RJ (Brazil). Dept. de Protecao Radiologica Ambiental; Ribeiro, Fernando C.A.; Alleluia, Irene B. [Instituto Nacional de Tecnologia (INT), Rio de Janeiro, RJ (Brazil). Div. de Meio Ambiente; Perez, Daniel V. [Empresa Brasileira de Pesquisa Agropecuaria (EMBRAPA), Rio de Janeiro, RJ (Brazil). Lab. de Analises de Solos e Plantas

    2001-07-01

    The fertilizer contribution to radio uptake by tomato plants was assessed. Tomato and soil samples from four different plantations were analyzed: two using organic fertilizer and two using phosphate fertilizer. The Ra concentrations in eight of the most used tomato fertilizers were determined. The concentration values ranged from 14 to 221 Bq/kg of Ra-226 and from 25 to 176 Bq/kg of Ra-228. Owing to the low Ra concentration and to the used fertilizer quantities, the fertilizers would not increase significantly the Ra soil concentration. However, the highest soil to plant concentration ratios were found in the plantations using phosphate fertilizers. This outcome pointed out the higher Ra availability in the phosphate fertilizer plantations than in the organic fertilizer plantations, showing a possible positive influence of phosphate fertilizers for the tomato Ra uptake. Due to the phosphate fertilizer used, the dose could increase from 0,05 Sv/year to 0,24 Sv/year. However this increase is not significant face the ingestion average worldwide effective dose. (author)

  17. A regulatory model for conformity evaluation in natural gas building installations; Um modelo regulatorio para avaliacao da conformidade das instalacoes prediais de gas natural

    Energy Technology Data Exchange (ETDEWEB)

    Fossa, Alberto Jose; Santos, Edmilson Moutinho dos [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Eletrotecnica e Energia

    2008-07-01

    The challenge of the Brazilian growth needs to consider necessarily the energy arrangements, and natural gas has relevant participation in this matter. The possibility of its end use that make possible an effective adequacy of our energy matrix must be supported by modern concepts of quality and conformity. In this particular, the program of 'Tecnologia Industrial Basica' (TIB), including concepts and application of conformity evaluation processes, is considered basic for the construction of a consistent gas market. This paper present the Brazilian reality related to TIB aspects and elements, from which it constructs a technician and regulatory building gas installations model proposal for a conformity evaluation program in the country. (author)

  18. Analysis of an in-line diesel production system through event driven simulation; Avaliacao do esquema de producao em linha de diesel atraves da simulacao por eventos discretos

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Gilsa P.; Naegeli, Guilherme S.T. [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES); Santos, Nilza M.Q. [PETROBRAS S.A., Mataripe, Salvador, BA (Brazil). Refinaria Landulfo Alves (RLAM); Netto, Joaquim D.A. [DNV Energy Solutions, Porto Alegre, RS (Brazil)

    2008-07-01

    The interactions between refining processes (such as distillation, hydrotreatment, etc.) and typical transfer and storage operations (mixtures, decantation, storage, etc.) provide a high complexity to the refineries production systems of petroleum derivatives. These production systems are characterized by many aspects, such as: blending rules, feed composition, petroleum campaigns, storage tanks limitations, continuous and batch processes interactions, etc. Besides these operational aspects, the equipment and systems' reliability has strong influence on the level of production goals achievement and petroleum derivatives quality specification. Looking for a higher economic efficiency and in order to provide refineries with orientation about resources optimization for their petroleum derivatives' production systems, the development of a methodology capable of being applied since the design phase to identify systems limitations and improvement opportunities, considering all the raised aspects, is a very important task. With this objective, this article presents the main points of an evaluation that was conducted during the conceptual design for a diesel in-line blending production system proposed by a Brazilian refinery, detailing the main steps of the methodology that was developed through this analysis, based on discrete event simulation. (author)

  19. Evaluation of biodegradation of bionanocomposites of PHB/PP-g-MA/vermiculite; Avaliacao da biodegradacao de bionanocompositos de PHB/PP-g-MA/vermiculita

    Energy Technology Data Exchange (ETDEWEB)

    Mesquita, P.J.P. de; Alves, T.S.; Barbosa, R., E-mail: tsaeng3@yahoo.com.br [Universidade Federal do Piaui (UFPI), Teresina, PI (Brazil). Programa de Pos-Graduacao em Ciencia dos Materiais; Andrade, D. de L.A.C.S. [Universidade Federal de Campina Grande (UFCG), PB (Brazil). Programa de Pos- Graduacao em Ciencia e Engenharia de Materiais

    2014-07-01

    In this work, we evaluated the process of biodegradation of PHB bionanocomposites/PP-g-MA/clay. Films were prepared with compositions of 5% PP-g-MA and 3% clay (BIO5); and 2.5% PP-g-MA and 3% clay (BIO2.5). The biodegradation test was conducted according to ASTM G 160-03 for a period of 86 days. The evaluation of biodegradation was performed by optical microscopy (MO), loss of mass, FTIR and XRD. The bionanocomposites presented change of coloration and appearance of fissures. As for loss in mass in the system presented loss of BIO2,5 22.5% and 25.9% BIO5, for 86 days of simulated soil exposure. We also observed by FTIR sharp reduction in intensity of the band corresponding to the C = O groups, indicating that the microbial attack promoted cleavage of the ester group links. By XRD, reduction in the intensity of the peaks and enlargements of the same with increasing exposure time, proving the biodegradation behavior of bionanocomposites. (author)

  20. Synthesis and antimicrobial activities of new 4-thiazolidones derived from formipyridine thiosemicarbazones; Sintese e avaliacao da atividade antimicrobiana de novas 4-tiazolidinonas obtidas a partir de formilpiridina tiossemicarbazonas

    Energy Technology Data Exchange (ETDEWEB)

    Vercoza, George Leonardo; Feitoza, Danniel Delmondes; Alves, Antonio Jose; Aquino, Thiago Mendonca de; Lima, Jose Gildo de [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Ciencias Farmaceuticas], e-mail: jgildolima@gmail.com; Araujo, Janete Magali; Cunha, Ivana Glaucia B.; Goes, Alexandre Jose da Silva [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Antibioticos

    2009-07-01

    Twelve novel 4-thiazolidinone derivatives (2a-l) have been synthesized by reacting formylpyridine thiosemicarbazones (1a-l) and anhydride maleic in toluene. Their chemical structures were confirmed by IR, {sup 1}H and {sup 13}C NMR. The new compounds were submitted to in vitro evaluation against pathogenic Gram-positive, Gram-negative bacteria and yeasts. The findings obtained showed that the compounds 2a, 2d, 2e and 2g were effective against some of the bacterial strains used, whereas the compounds 2d, 2e and 2i exhibited a moderate antifungal activity against the yeast strains evaluated. An initial structure activity relationship (SAR) was established. (author)

  1. Bacteriological evaluation of fresh chicken sausage submitted to gamma radiation; Avaliacao bacteriologica da linguica de frango Frescal submetida a radiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Alexandre

    2002-07-01

    Many developed countries have established a goal of self-sufficiency in food production, while many other obtain their principal foreign exchange through food exports. For these reasons, it is essential to eliminate losses in food products. It is no less important to prevent or combat food-transmitted diseases, principally across poultry and poultry derivatives, which play a major role in certain infections and is the focus of national public health goals in order to increase the international commerce. In tropical countries, perishable products represent the largest markets. The population lives in a constant battle against the deterioration of these foods. Such loss is enormous where the climate favors the proliferation of agents of decomposition and acceleration of putrification. Increasing the useful life of these perishable products will provide producers the option of commercializing them in low harvest season, thus achieving higher prices, and providing sensible growth to the agro-industrial market. Treatment of perishables with gamma radiation presently constitutes one of the most modern, safe, and efficient methods for increasing food preservation. The irradiation of foods can offer various special advantages such as: kill or sterilize pathogenic organisms in food, improving their quality and duration, reducing the level of toxics, slow or stop the aging of roots and tubers, disinfect products of animal and vegetable origin thus slowing their decomposition, increasing their shelf-life, and prolonging their conservation refrigeration. The practice of irradiating foods for the treatment of microorganisms has begun to gain momentum in Brazil, where roughly 25% of all food produced annually is lost to disease and insects activity, increased by lack of adequate storage treatments. Various countries have already adopted the method that, when practiced properly by qualified professionals, does not cause side effects other than the extension of useful life. In light of the lack of present data on the irradiation of fresh chicken sausage, the objective of this study is to evaluate determine the efficiency of this method as a process for reducing the microbial load via measurement of the bacteriology of the product before and after gamma radiation. 45 sample of chicken sausage(acquired directly from the poultry industry) were prepared divided in 3 treatments: the first is a control, the second and third using application of 1,5 and 3,0 kGy, respectively. The chicken sausages irradiated with a dose of 1,5 kGy did not have, statistically significant results apparent in the bacteriological measures. Samples irradiated with 3,0 kGy did experience statistically significant reductions. It is concluded that the irradiating the product with a dose of 3,0 kGy is more effective for the reduction of bacterial population, with the data in these trials indicating a 95,3% reduction in total coliforms, 100% removal of fecal coliforms, and 84,0% reduction of mesophiles, relative to the control samples. (author)

  2. Situational quality evaluation of mammography services at state of Minas Gerais, Brazil; Avaliacao situacional da qualidade dos servicos de mamografia do estado de Minas Gerais, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Joana, Georgia S.; Oliveira, Mauricio de; Andrade, Mauricio C. de; Cesar, Adriana C.Z., E-mail: georgia.santos@saude.mg.gov.b, E-mail: mauricio.cavalcanti@saude.mg.gov.b, E-mail: adrianac@saude.mg.gov.b, E-mail: mauricio.oliveira@saude.mg.gov.b [Secretaria de Estado da Saude de Minas Gerais (SVS/SES-MG), Belo Horizonte, MG (Brazil). Superintendencia de Vigilancia Sanitaria; Oliveira, Marcio A.; Nogueira, Maria do S., E-mail: marcio.alves@saude.mg.gov.b, E-mail: mnogue@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Peixoto, Joao E. [Instituto Nacional de Cancer (INCA), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    Breast cancer is the leading cause of cancer deaths in women. Currently, the most effective method for early detection of this cancer is the mammography, and to achieve the standard definition and contrast, the whole system of imaging must operate under optimal conditions. This paper presents the results of the assessment of mammography centers in the state of Minas Gerais, which was held with the aim of supporting the actions of the State Program of Quality Control in Mammography. These results indicated that less than half of mammography achieved the minimum standard of image quality, endorsing the need of a monitoring more efficient and effective, which led to the establishment, in Minas Gerais, of the monthly monitoring of image quality in mammography. (author)

  3. Comparison of the automated evaluation of phantom mama in digital and digitalized images; Comparacao da avaliacao automatizada do phantom mama em imagens digitais e digitalizadas

    Energy Technology Data Exchange (ETDEWEB)

    Santana, Priscila do Carmo, E-mail: pcs@cdtn.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear. Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares; Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Fac. de Medicina. Dept. de Propedeutica Complementar; Gomes, Danielle Soares; Oliveira, Marcio Alves; Nogueira, Maria do Socorro, E-mail: mnogue@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Mammography is an essential tool for diagnosis and early detection of breast cancer if it is provided as a very good quality service. The process of evaluating the quality of radiographic images in general, and mammography in particular, can be much more accurate, practical and fast with the help of computer analysis tools. This work compare the automated methodology for the evaluation of scanned digital images the phantom mama. By applied the DIP method techniques was possible determine geometrical and radiometric images evaluated. The evaluated parameters include circular details of low contrast, contrast ratio, spatial resolution, tumor masses, optical density and background in Phantom Mama scanned and digitized images. The both results of images were evaluated. Through this comparison was possible to demonstrate that this automated methodology is presented as a promising alternative for the reduction or elimination of subjectivity in both types of images, but the Phantom Mama present insufficient parameters for spatial resolution evaluation. (author)

  4. Impact of an evaluation quality program of mammography service of Distrito Federal - Brasil; Impacto de um programa de avaliacao da qualidade dos servicos de mamografia do Distrito Federal

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Rosangela da Silveira

    2002-07-01

    Cancer is the second cause of death for Brazilian women and breast cancer is the most common neoplasm amongst women. Mammography is an essential tool for diagnosis and early detection of this disease. In order to be effective, the mammography must be of good quality. This study sought to evaluate the quality of these services in the Federal District and the impact of an intervention involving inspection and education. The universe of 41 mammography services in the Federal District was studied between June and August 2001. Two instruments were used 1) a proposed evaluation protocol of the National Agency for Health Surveillance (ANVISA) and 2) a protocol for evaluation of image quality and care. The intervention included the initial inspection, a training activity, and a formal notification by the health authorities of the Federal District. Image quality was compared before and after the intervention. The existing infrastructure in the DF is of good quality, but the services have low productivity, they do not treat patients sent by the public health system, they have an inadequate geographic distribution with most in the central neighborhood, and the low income female population has restricted access to early detection of cancer. Of the 36 services who completed the study, none was above 90% conformity in image quality before the interventions, whereas 10 were above 90% afterwards. The greatest improvements were in chassis maintenance (services without chassis with defects went from 10 to 25), breast compression (services in conformity went from 7 to 20) and visualization of micro calcifications (32 services in conformity before and 35 afterwards). The results of the ANVISA protocol bore no relation to final image quality, a central issue for early cancer detection. In spite of the existence of many services, most were not of quality and population access was restricted. The intervention under study was shown to be effective for improving quality, nevertheless ongoing action is needed to resolve the remaining problems and to increase the impact. The proposed method for public monitoring should be modified to evaluate primarily the quality of the final exam provided to the consumer. (author)

  5. Residual stress evaluation and curvature behavior of aluminum 7050 peen forming processed; Avaliacao da tensao residual em aluminio 7050 conformado pelo processo peen forming

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Rene Ramos de

    2011-07-01

    Shot peening is a superficial cold work process used to increase the fatigue life evaluated by residual stress measurements. The peen forming process is a variant of the shot peening process, where a curvature in the plate is obtained by the compression of the grains near to the surface. In this paper, the influence of the parameters such as: pressure of shot, ball shot size and thickness of aluminum 7050 samples with respect to residual stress profile and resulting arc height was studied. The evaluation of the residual stress profile was obtained by sin{sup 2} {psi} method. The results show that the formation of the curvature arc height is proportional to the shot peening pressure, of spheres size and inversely proportional to the thickness of the sample, and that stress concentration factor is larger for samples shot peened with small balls. On final of this paper presents an additional study on micro strain and average crystallite size, which can evaluate the profile of the samples after blasting. (author)

  6. Evaluation of the strengthening of the conditions of voltage security using sensitivity analysis; Avaliacao do reforco das condicoes da seguranca de tensao utilizando a analise de sensibilidade

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, A.L.S.; Costa, V.M. da; Peres, W. [Universidade Federal de Juiz de Fora (UFJF), MG (Brazil). Faculdade de Engenharia], Emails: arleilucas@gmail.com, vander@lacee.ufjf.br, wesley.peres@yahoo.com.br; Prada, R.B. [Pontificia Universidade Catolica (PUC-Rio), Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Eletrica], Email: prada@ele.puc-rio.br

    2009-07-01

    Voltage stability or voltage security analysis has motivated an expressive attention of power systems researchers. In this work, a simple and fast method evaluates voltage security and proposes conditions to improve the loading margin. System analysis is carried out in terms of active power transmission path. Sensitivity analysis provides the most adequate buses to active and reactive power redispatch. A sequential iterative methodology to reinforce system conditions is presented. (author)

  7. Highly resolving computerized tomography

    International Nuclear Information System (INIS)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions. (BWU) [de

  8. Highly resolving computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions.

  9. Mathematical Methods in Tomography

    CERN Document Server

    Louis, Alfred; Natterer, Frank

    1991-01-01

    The conference was devoted to the discussion of present and future techniques in medical imaging, including 3D x-ray CT, ultrasound and diffraction tomography, and biomagnetic ima- ging. The mathematical models, their theoretical aspects and the development of algorithms were treated. The proceedings contains surveys on reconstruction in inverse obstacle scat- tering, inversion in 3D, and constrained least squares pro- blems.Research papers include besides the mentioned imaging techniques presentations on image reconstruction in Hilbert spaces, singular value decompositions, 3D cone beam recon- struction, diffuse tomography, regularization of ill-posed problems, evaluation reconstruction algorithms and applica- tions in non-medical fields. Contents: Theoretical Aspects: J.Boman: Helgason' s support theorem for Radon transforms-a newproof and a generalization -P.Maass: Singular value de- compositions for Radon transforms- W.R.Madych: Image recon- struction in Hilbert space -R.G.Mukhometov: A problem of in- teg...

  10. Neutron beam tomography software

    International Nuclear Information System (INIS)

    Newbery, A.C.R.

    1988-05-01

    When a sample is traversed by a neutron beam, inhomogeneities in the sample will cause deflections, and the deflections will permit conclusions to be drawn concerning the location and size of the inhomogeneities. The associated computation is similar to problems in tomography, analogous to X-ray tomography though significantly different in detail. We do not have any point-sample information, but only mean values over short line segments. Since each mean value is derived from a separate neutron counter, the quantity of available data has to be modest; also, since each datum is an integral, its geometric precision is inferior to that of X-ray data. Our software is designed to cope with these difficulties. (orig.) [de

  11. Positron emission tomography

    International Nuclear Information System (INIS)

    Yamamoto, Y.L.; Thompson, C.J.; Diksic, M.; Meyer, E.; Feindel, W.H.

    1984-01-01

    One of the most exciting new technologies introduced in the last 10 yr is positron emission tomography (PET). PET provides quantitative, three-dimensional images for the study of specific biochemical and physiological processes in the human body. This approach is analogous to quantitative in-vivo autoradiography but has the added advantage of permitting non-invasive in vivo studies. PET scanning requires a small cyclotron to produce short-lived positron emitting isotopes such as oxygen-15, carbon-11, nitrogen-13 and fluorine-18. Proper radiochemical facilities and advanced computer equipment are also needed. Most important, PET requires a multidisciplinary scientific team of physicists, radiochemists, mathematicians, biochemists and physicians. The most recent trends are reviewed in the imaging technology, radiochemistry, methodology and clinical applications of positron emission tomography. (author)

  12. Reinforced concrete tomography

    International Nuclear Information System (INIS)

    Mariscotti, M.A.J.; Morixe, M.; Tarela, P.A.; Thieberger, P.

    1997-01-01

    In this paper we describe the technique of reinforced concrete tomography, its historical background, recent technological developments and main applications. Gamma radiation sensitive plates are imprinted with radiation going through the concrete sample under study, and then processed to reveal the presence of reinforcement and defects in the material density. The three dimensional reconstruction, or tomography, of the reinforcement out of a single gammagraphy is an original development alternative to conventional methods. Re-bar diameters and positions may be determined with an accuracy of ± 1 mm 0.5-1 cm, respectively. The non-destructive character of this technique makes it particularly attractive in cases of inhabited buildings and diagnoses of balconies. (author) [es

  13. Optical Tomography in Combustion

    DEFF Research Database (Denmark)

    Evseev, Vadim

    spectral measurements at several line-of-sights with a view to applications for tomographic measurements on full-scale industrial combustion systems. The system was successfully applied on industrial scale for simultaneous fast exhaust gas temperature measurements in the three optical ports of the exhaust......D project, it was also important to investigate the spectral properties of major combustion species such as carbon dioxide and carbon monoxide in the infrared range at high temperatures to provide the theoretical background for the development of the optical tomography methods. The new software....... JQSRT 113 (2012) 2222, 10.1016/j.jqsrt.2012.07.015] included in the PhD thesis as an attachment. The knowledge and experience gained in the PhD project is the first important step towards introducing the advanced optical tomography methods of combustion diagnostics developed in the project to future...

  14. Computed Tomography. Chapter 11

    Energy Technology Data Exchange (ETDEWEB)

    Geleijns, J. [Leiden University Medical Centre, Leiden (Netherlands)

    2014-09-15

    After its clinical introduction in 1971, computed tomography (CT) developed from an X ray modality that was limited to axial imaging of the brain in neuroradiology into a versatile 3-D whole body imaging modality for a wide range of applications, including oncology, vascular radiology, cardiology, traumatology and interventional radiology. CT is applied for diagnosis and follow-up studies of patients, for planning of radiotherapy, and even for screening of healthy subpopulations with specific risk factors.

  15. Positron emission tomography

    International Nuclear Information System (INIS)

    Chandrasekhar, Preethi; Himabindu, Pucha

    2000-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging technique used to study different molecular pathways and anatomical structures. PET has found extensive applications in various fields of medicine viz. cardiology, oncology, psychiatry/psychology, neuro science and pulmonology. This study paper basically deals with the physics, chemistry and biology behind the PET technique. It discusses the methodology for generation of the radiotracers responsible for emission of positrons and the annihilation and detection techniques. (author)

  16. Compton tomography system

    Science.gov (United States)

    Grubsky, Victor; Romanoov, Volodymyr; Shoemaker, Keith; Patton, Edward Matthew; Jannson, Tomasz

    2016-02-02

    A Compton tomography system comprises an x-ray source configured to produce a planar x-ray beam. The beam irradiates a slice of an object to be imaged, producing Compton-scattered x-rays. The Compton-scattered x-rays are imaged by an x-ray camera. Translation of the object with respect to the source and camera or vice versa allows three-dimensional object imaging.

  17. High resolution positron tomography

    International Nuclear Information System (INIS)

    Brownell, G.L.; Burnham, C.A.

    1982-01-01

    The limits of spatial resolution in practical positron tomography are examined. The four factors that limit spatial resolution are: positron range; small angle deviation; detector dimensions and properties; statistics. Of these factors, positron range may be considered the fundamental physical limitation since it is independent of instrument properties. The other factors are to a greater or lesser extent dependent on the design of the tomograph

  18. Positron emission tomography

    International Nuclear Information System (INIS)

    Marchenkov, N.S.

    2000-01-01

    The foundations of the positron emission tomography (PET), widely used for the medical diagnostics, are considered. The brief description of the cyclotron for production of radionuclides, applied in the PET, the target devices for manufacturing the position emitters, the moduli for the radiopharmaceuticals synthesis (RPS) for the PET is presented. The necessity and concept of complete automation of the RPS for the PET are discussed [ru

  19. Computed Tomography Status

    Science.gov (United States)

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  20. Coded aperture tomography revisited

    International Nuclear Information System (INIS)

    Bizais, Y.; Rowe, R.W.; Zubal, I.G.; Bennett, G.W.; Brill, A.B.

    1983-01-01

    Coded aperture (CA) Tomography never achieved wide spread use in Nuclear Medicine, except for the degenerate case of Seven Pinhole tomagraphy (7PHT). However it enjoys several attractive features (high sensitivity and tomographic ability with a statis detector). On the other hand, resolution is usually poor especially along the depth axis and the reconstructed volume is rather limited. Arguments are presented justifying the position that CA tomography can be useful for imaging time-varying 3D structures, if its major drawbacks (poor longitudinal resolution and difficulty in quantification) are overcome. Poor results obtained with 7PHT can be explained by both a very limited angular range sampled and a crude modelling of the image formation process. Therefore improvements can be expected by the use of a dual-detector system, along with a better understanding of its sampling properties and the use of more powerful reconstruction algorithms. Non overlapping multipinhole plates, because they do not involve a decoding procedure, should be considered first for practical applications. Use of real CA should be considered for cases in which non overlapping multipinhole plates do not lead to satisfactory solutions. We have been and currently are carrying out theoretical and experimental works, in order to define the factors which limit CA imaging and to propose satisfactory solutions for Dynamic Emission Tomography

  1. Cardiac positron tomography

    International Nuclear Information System (INIS)

    Geltmann, E.M.; Roberts, R.; Sobel, B.E.

    1980-01-01

    Positron emission tomography (PET) performed after the administration of the positron-emitting radionuclides carbon-11 ( 11 C), nitrogen-13 ( 13 N), oxygen-15 ( 15 O) and fluorine-18 ( 18 F) has permitted the improved noninvasive assessment of the regional myocardial metabolism of normal physiologic substrates and intermediates and their cogeners. In experimental animals, the rate of oxidation of 11 C-palmitate correlates closely with other indexes of oxygen consumption, and the extraction of 11 C-palmitate (like that of 18 F-fatty acids and 18 F-fluoredoxyglucose) ist markedly diminished in regions of myocardial ischemia. In both experimental animals and in patients, myocardial infarct site and size, determined by positron emission tomography after the intravenous injection of 11 C-palmitate, correlate closely with the electrocardiographic infarct locus and enzymatically estimated infarct size as well as with the location and extent of regional left ventricular wall motion abnormalities. PET offers promise for assessment of flow as well despite the complexities involved. PET with 13 NH 3 appears to provide one useful qualitative index, although this tracer ist actively metabolized. Because of the quantitative capabilities of positron emission tomography and the rapid progress which is being made in the development of fast scan, multi-slice, and gated instrumentation, this technique is likely to facilitate improved understanding and characterization of regional myocardial metabolism and blood flow in man under physiological and pathophysiological conditions. (orig.) [de

  2. Mathematics of Computed Tomography

    Science.gov (United States)

    Hawkins, William Grant

    A review of the applications of the Radon transform is presented, with emphasis on emission computed tomography and transmission computed tomography. The theory of the 2D and 3D Radon transforms, and the effects of attenuation for emission computed tomography are presented. The algebraic iterative methods, their importance and limitations are reviewed. Analytic solutions of the 2D problem the convolution and frequency filtering methods based on linear shift invariant theory, and the solution of the circular harmonic decomposition by integral transform theory--are reviewed. The relation between the invisible kernels, the inverse circular harmonic transform, and the consistency conditions are demonstrated. The discussion and review are extended to the 3D problem-convolution, frequency filtering, spherical harmonic transform solutions, and consistency conditions. The Cormack algorithm based on reconstruction with Zernike polynomials is reviewed. An analogous algorithm and set of reconstruction polynomials is developed for the spherical harmonic transform. The relations between the consistency conditions, boundary conditions and orthogonal basis functions for the 2D projection harmonics are delineated and extended to the 3D case. The equivalence of the inverse circular harmonic transform, the inverse Radon transform, and the inverse Cormack transform is presented. The use of the number of nodes of a projection harmonic as a filter is discussed. Numerical methods for the efficient implementation of angular harmonic algorithms based on orthogonal functions and stable recursion are presented. The derivation of a lower bound for the signal-to-noise ratio of the Cormack algorithm is derived.

  3. In Vivo Diffuse Optical Tomography and Fluorescence Molecular Tomography

    Directory of Open Access Journals (Sweden)

    Mingze Li

    2010-01-01

    Full Text Available Diffuse optical tomography (DOT and fluorescence molecular tomography (FMT are two attractive imaging techniques for in vivo physiological and psychological research. They have distinct advantages such as non-invasiveness, non-ionizing radiation, high sensitivity and longitudinal monitoring. This paper reviews the key components of DOT and FMT. Light propagation model, mathematical reconstruction algorithm, imaging instrumentation and medical applications are included. Future challenges and perspective on optical tomography are discussed.

  4. Evaluation of ambient radiation levels in positron emission tomography/computed tomography in microPET/CT laboratory; Avaliacao dos niveis de radiacao ambiental no laboratorio de tomografia por emissao de positrons acoplada a tomografia computadorizada, microPET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Sarmento, Daniele Martins

    2016-11-01

    Micro PET/CT scanner is an essential tool generally used for small animal molecular imaging. Fluorine-18-labeled fluorodeoxyglucose is the most widely used radioisotope in this technique. The present study aimed to evaluate the radiation levels in a micro PET/CT research laboratory of the Radiopharmacy Center at IPEN-CNEN / SP, in order to accomplish both national standards and international recommendations. The radioprotection team has classified the laboratory as supervised area; even this laboratory does not require the adoption of specific measures for protection and safety, should be done regular re-evaluation of the conditions of occupational exposures. Workplace monitoring and individual control assessment were carried out to ensure the radiological protection of all workers directly involved in handling the scanner. Initially, there was conducted a radiometric survey, as well as measurements of the external radiation level in the workplace and its surroundings. To achieve this goal, there were placed nine thermoluminescent dosimeters of CaSO{sub 4}:Dy in preselected locations. Monthly evaluations of the occupationally exposed individuals were carried out through the use of TL dosimeters, ported in the workers' chest. Moreover, whole body measurements were performed every six months. The study period was about two-years which started in April 2014. All tests to evaluate micro PET/CT performance were based on the standard protocol of the equipment in accordance with the standard developed by the Animal PET Standard Task Force. Present study's results demonstrated that the ambient radiation levels (ambient and effective estimated radiation dose), as well as the effective shielding equipment are both adequate. This study emphasizes that it is essential to strictly follow the principles of radioprotection in workplace, whenever researches involve radioactive unsealed sources. (author)

  5. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  6. Scanning Microwave Induced Acoustic Tomography

    National Research Council Canada - National Science Library

    Wang, Lihong V

    2002-01-01

    .... Specifically, our accomplishments include (1) an exact and an approximate time-domain reconstruction algorithm for thermoacoustic tomography in a spherical geometry was derived and published, (2...

  7. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs

  8. Computed tomography device

    International Nuclear Information System (INIS)

    Ohhashi, A.

    1985-01-01

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  9. Compressive Phase Contrast Tomography

    International Nuclear Information System (INIS)

    Maia, Filipe; MacDowell, Alastair; Marchesini, Stefano; Padmore, Howard A.; Parkinson, Dula Y.; Pien, Jack; Schirotzek, Andre; Yang, Chao

    2010-01-01

    When x-rays penetrate soft matter, their phase changes more rapidly than their amplitude. Interference effects visible with high brightness sources creates higher contrast, edge enhanced images. When the object is piecewise smooth (made of big blocks of a few components), such higher contrast datasets have a sparse solution. We apply basis pursuit solvers to improve SNR, remove ring artifacts, reduce the number of views and radiation dose from phase contrast datasets collected at the Hard X-Ray Micro Tomography Beamline at the Advanced Light Source. We report a GPU code for the most computationally intensive task, the gridding and inverse gridding algorithm (non uniform sampled Fourier transform).

  10. Positron Emission Tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  11. Recent RI tomography

    International Nuclear Information System (INIS)

    Katsuyama, Naofumi; Kawakami, Kenshi

    1979-01-01

    In this paper, new equipments for radionuclide tomography and recent radiopharmaceuticals with positron emission are described. Positron CT is very usefull for functional imaging. Those nucleides 11 C, 13 N and 15 O have been studied for their sake, but used as a usefull tool as tracer elements for the basic research in the fields of chemistry, bio-chemistry, biology and medicine. Also they have been utilized in the diagnosis of diseases, particularly in the non-invasive and dynamic assessment of metabolic and functional disorders in the patients. We will also describe the clinical usefullness of a commercial scanner such as the Anger multiplane tomographic scanner (PHO/CON). (author)

  12. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; Peterson, T.E.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented especially of the ball bearing races used in the rotation. (U.K.)

  13. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Brandt, R.T.; Hein, P.W.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented. (U.K.)

  14. Method for computed tomography

    International Nuclear Information System (INIS)

    Wagner, W.

    1980-01-01

    In transversal computer tomography apparatus, in which the positioning zone in which the patient can be positioned is larger than the scanning zone in which a body slice can be scanned, reconstruction errors are liable to occur. These errors are caused by incomplete irradiation of the body during examination. They become manifest not only as an incorrect image of the area not irradiated, but also have an adverse effect on the image of the other, completely irradiated areas. The invention enables reduction of these errors

  15. Positron Emission Tomography (PET)

    Science.gov (United States)

    Welch, M. J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.

  16. Solar Stereoscopy and Tomography

    Directory of Open Access Journals (Sweden)

    Markus J. Aschwanden

    2011-10-01

    Full Text Available We review stereoscopic and tomographic methods used in the solar corona, including ground-based and space-based measurements, using solar rotation or multiple spacecraft vantage points, in particular from the STEREO mission during 2007--2010. Stereoscopic and tomographic observations in the solar corona include large-scale structures, streamers, active regions, coronal loops, loop oscillations, acoustic waves in loops, erupting filaments and prominences, bright points, jets, plumes, flares, CME source regions, and CME-triggered global coronal waves. Applications in the solar interior (helioseismic tomography and reconstruction and tracking of CMEs from the outer corona and into the heliosphere (interplanetary CMEs are not included.

  17. Radial reflection diffraction tomography

    Science.gov (United States)

    Lehman, Sean K.

    2012-12-18

    A wave-based tomographic imaging method and apparatus based upon one or more rotating radially outward oriented transmitting and receiving elements have been developed for non-destructive evaluation. At successive angular locations at a fixed radius, a predetermined transmitting element can launch a primary field and one or more predetermined receiving elements can collect the backscattered field in a "pitch/catch" operation. A Hilbert space inverse wave (HSIW) algorithm can construct images of the received scattered energy waves using operating modes chosen for a particular application. Applications include, improved intravascular imaging, bore hole tomography, and non-destructive evaluation (NDE) of parts having existing access holes.

  18. Positron emission tomography

    CERN Document Server

    Paans, A M J

    2006-01-01

    Positron Emission Tomography (PET) is a method for measuring biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides such as 11C, 13N, 15O and 18F and by measuring the annihilation radiation using a coincidence technique. This includes also the measurement of the pharmacokinetics of labelled drugs and the measurement of the effects of drugs on metabolism. Also deviations of normal metabolism can be measured and insight into biological processes responsible for diseases can be obtained. At present the combined PET/CT scanner is the most frequently used scanner for whole-body scanning in the field of oncology.

  19. Positron emission tomography

    International Nuclear Information System (INIS)

    Paans, A.M.J.

    1981-01-01

    Positron emitting radiopharmaceuticals have special applications in in-vivo studies of biochemical processes. The combination of a cyclotron for the production of radionuclides and a positron emission tomograph for the registration of the distribution of radioactivity in the body enables the measurement of local radioactivity concentration in tissues, and opens up new possibilities in the diagnosis and examination of abnormalities in the metabolism. The principles and procedures of positron emission tomography are described and the necessary apparatus considered, with emphasis on the positron camera. The first clinical applications using 55 Co bloemycine for tumor detection are presented. (C.F.)

  20. Dynamic tomography in dentistry

    International Nuclear Information System (INIS)

    Richards, A.G.

    1976-01-01

    Dynamic tomography is a procedure in which a sandwich of eight underexposed radiographs is utilized to display sharp images of details lying in a thin layer at any chosen depth within a subject. When the sandwich of films is viewed by transmitted light, the location of this chosen layer can be moved up or down within the subject by simply mechanically moving the radiographs in a precise manner relative to each other. The amount of radiation used in exposing the eight radiographs is the same as would be used to fully expose two normal radiographs

  1. Dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Andisco, D.; Blanco, S.; Buzzia, A.E.

    2014-01-01

    Objective: The amount of computed tomography (CT) studies that are performed each year in the world is growing exponentially mainly due to the incorporation of multislice CT that allows studies in a few seconds. But, despite the benefit received by patients with the diagnosis, radiation dose is a concern in the professional community and it has be reduced as much as reasonably possible. This article describes the main dosimetric CT units used in order to work with this practice easily, using the values that provide modern equipment and internationally known reference levels. (authors) [es

  2. Practical adaptive quantum tomography

    Science.gov (United States)

    Granade, Christopher; Ferrie, Christopher; Flammia, Steven T.

    2017-11-01

    We introduce a fast and accurate heuristic for adaptive tomography that addresses many of the limitations of prior methods. Previous approaches were either too computationally intensive or tailored to handle special cases such as single qubits or pure states. By contrast, our approach combines the efficiency of online optimization with generally applicable and well-motivated data-processing techniques. We numerically demonstrate these advantages in several scenarios including mixed states, higher-dimensional systems, and restricted measurements. http://cgranade.com complete data and source code for this work are available online [1], and can be previewed at https://goo.gl/koiWxR.

  3. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  4. Filosofia da análise da estabilidade da liquidez

    Directory of Open Access Journals (Sweden)

    Rodrigo Antônio Chaves da Silva

    2005-07-01

    Full Text Available A informação foi considerada finalidade de nosso conhecimento, até o período em os pensadores e pesquisadores da contabilidade passaram a raciocinar sobre o conteúdo e o significado dos informes. Nesta busca da razão sobre os estados patrimoniais, surgiu a análise contábil que procura por meio de relações e identidades, o significado da dinâmica expressa da estaticamente na informação. O primeiro aspecto que surgiu no objeto de análise foi o estudo da liquidez, que é um dos principais exercícios do patrimônio. A estabilidade também é outro exercício básico e imprescindível, pois este é que promove o equilíbrio do organismo administrativo. A ciência contábil após a sua dignidade científica passou a trilhar caminhos esplendorosos, amparados em doutrina que permite alcançar os píncaros filosóficos. Os estudos concernentes aos aspectos de interação da estabilidade na liquidez são, complexos e somente com os recursos filosóficos da contabilidade se pode estudá-los com o panorama holístico e sublime. A filosofia da contabilidade não é alheia às suas práticas tecnológicas, podendo buscar pontos sublimes de panoramas abrangentes, para o estudo analítico da liquidez e estabilidade, observando todas as dimensionalidades e essencialidades de acontecimentos, na comprovação e orientação dos estados de ineficácia e eficácia patrimonial.

  5. Auroral Tomography Workshop, Proceedings

    International Nuclear Information System (INIS)

    Steen, Aa.

    1993-08-01

    In ionospheric and atmospheric physics the importance of multi-station imaging has grown as a consequence of the availability of scientific grade CCD cameras with digital output and affordable massive computing power. Tomographic inversion techniques are used in many different areas, e.g. medicine, plasma research and space physics. The tomography workshop was announced to gather a limited group of people interested in auroral tomography or tomographic inversion methods in general. ALIS (Auroral Large Imaging System) is a multi-station ground-based system developed primarily for three-dimensional auroral imaging, however other non-auroral objects can be studied with ALIS, e.g. stratospheric clouds. Several of the contributions in the workshop dealt with problems related to geometries similar to the ALIS-configuration. The Proceedings contain written contributions received either in abstract form or as full papers. The Proceedings also contain contributions intended for the Workshop but not presented due to the absence of the speaker. Separate abstracts have been prepared for 15 of the 17 papers

  6. Compressed sensing electron tomography

    International Nuclear Information System (INIS)

    Leary, Rowan; Saghi, Zineb; Midgley, Paul A.; Holland, Daniel J.

    2013-01-01

    The recent mathematical concept of compressed sensing (CS) asserts that a small number of well-chosen measurements can suffice to reconstruct signals that are amenable to sparse or compressible representation. In addition to powerful theoretical results, the principles of CS are being exploited increasingly across a range of experiments to yield substantial performance gains relative to conventional approaches. In this work we describe the application of CS to electron tomography (ET) reconstruction and demonstrate the efficacy of CS–ET with several example studies. Artefacts present in conventional ET reconstructions such as streaking, blurring of object boundaries and elongation are markedly reduced, and robust reconstruction is shown to be possible from far fewer projections than are normally used. The CS–ET approach enables more reliable quantitative analysis of the reconstructions as well as novel 3D studies from extremely limited data. - Highlights: • Compressed sensing (CS) theory and its application to electron tomography (ET) is described. • The practical implementation of CS–ET is outlined and its efficacy demonstrated with examples. • High fidelity tomographic reconstruction is possible from a small number of images. • The CS–ET reconstructions can be more reliably segmented and analysed quantitatively. • CS–ET is applicable to different image content by choice of an appropriate sparsifying transform

  7. Positron emission tomography. Positronemisionstomografi

    Energy Technology Data Exchange (ETDEWEB)

    Bolwig, T G; Haunsoe, S; Dahlgaard Hove, J; Hesse, B; Hoejgard, L; Jensen, M; Paulson, O B; Hastrup Svendsen, J; Soelvsten Soerensen, S

    1994-10-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ([sup 11]C), oxygen ([sup 15]O), and nitrogen ([sup 13]N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.).

  8. Waste inspection tomography (WIT)

    Energy Technology Data Exchange (ETDEWEB)

    Bernardi, R.T. [Bio-Imaging Research, Inc., Lincolnshire, IL (United States)

    1995-10-01

    Waste Inspection Tomography (WIT) provides mobile semi-trailer mounted nondestructive examination (NDE) and assay (NDA) for nuclear waste drum characterization. WIT uses various computed tomography (CT) methods for both NDE and NDA of nuclear waste drums. Low level waste (LLW), transuranic (TRU), and mixed radioactive waste can be inspected and characterized without opening the drums. With externally transmitted x-ray NDE techniques, WIT has the ability to identify high density waste materials like heavy metals, define drum contents in two- and three-dimensional space, quantify free liquid volumes through density and x-ray attenuation coefficient discrimination, and measure drum wall thickness. With waste emitting gamma-ray NDA techniques, WIT can locate gamma emitting radioactive sources in two- and three-dimensional space, identify gamma emitting, isotopic species, identify the external activity levels of emitting gamma-ray sources, correct for waste matrix attenuation, provide internal activity approximations, and provide the data needed for waste classification as LLW or TRU.

  9. Transverse tomography and radiotherapy

    International Nuclear Information System (INIS)

    Leer, J.W.H.

    1982-01-01

    This study was intended to delineate the indications for radiotherapy treatment-planning with the help of computerized axial tomography (C.T.) and transverse analog tomography (T.A.T.). Radiotherapy localisation procedures with the conventional method (simulator), with the CT-scanner and with the transverse analog tomograph (T.A.T., Simtomix, Oldelft) were compared. As criterium for evaluation differences in reconstruction drawing based on these methods were used. A certain method was judged ''superior'' to another if the delineation of the target volume was more accurate, if a better impression was gained of the site of (for irradiation) organs at risk, or if the localisation could only be performed with that method. The selected group of patients consisted of 120 patients for whom a reconstruction drawing in the transverse plane was made according to the treatment philosophy. In this group CT-assisted localisation was judged on 68 occasions superior to the conventional method. In a number of cases it was found that a ''standard'' change in a standard target volume, on the base of augmented anatomical knowledge, made the conventional method sufficient. The use of CT-scanner for treatment planning was estimated. For ca. 270/1000 new patients a CT-scan is helpful (diagnostic scan), for 140 of them the scan is necessary (planning scan). The quality of the anatomical information obtained with the T.A.T. does not yet fall within acceptable limits, but progress has been made. (Auth.)

  10. Positron emission tomography

    International Nuclear Information System (INIS)

    Bolwig, T.G.; Haunsoe, S.; Dahlgaard Hove, J.; Hesse, B.; Hoejgard, L.; Jensen, M.; Paulson, O.B.; Hastrup Svendsen, J.; Soelvsten Soerensen, S.

    1994-01-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ( 11 C), oxygen ( 15 O), and nitrogen ( 13 N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.)

  11. Waste inspection tomography (WIT)

    International Nuclear Information System (INIS)

    Bernardi, R.T.

    1995-01-01

    Waste Inspection Tomography (WIT) provides mobile semi-trailer mounted nondestructive examination (NDE) and assay (NDA) for nuclear waste drum characterization. WIT uses various computed tomography (CT) methods for both NDE and NDA of nuclear waste drums. Low level waste (LLW), transuranic (TRU), and mixed radioactive waste can be inspected and characterized without opening the drums. With externally transmitted x-ray NDE techniques, WIT has the ability to identify high density waste materials like heavy metals, define drum contents in two- and three-dimensional space, quantify free liquid volumes through density and x-ray attenuation coefficient discrimination, and measure drum wall thickness. With waste emitting gamma-ray NDA techniques, WIT can locate gamma emitting radioactive sources in two- and three-dimensional space, identify gamma emitting, isotopic species, identify the external activity levels of emitting gamma-ray sources, correct for waste matrix attenuation, provide internal activity approximations, and provide the data needed for waste classification as LLW or TRU

  12. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  13. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  14. EDITORIAL: Industrial Process Tomography

    Science.gov (United States)

    Anton Johansen, Geir; Wang, Mi

    2008-09-01

    There has been tremendous development within measurement science and technology over the past couple of decades. New sensor technologies and compact versatile signal recovery electronics are continuously expanding the limits of what can be measured and the accuracy with which this can be done. Miniaturization of sensors and the use of nanotechnology push these limits further. Also, thanks to powerful and cost-effective computer systems, sophisticated measurement and reconstruction algorithms previously only accessible in advanced laboratories are now available for in situ online measurement systems. The process industries increasingly require more process-related information, motivated by key issues such as improved process control, process utilization and process yields, ultimately driven by cost-effectiveness, quality assurance, environmental and safety demands. Industrial process tomography methods have taken advantage of the general progress in measurement science, and aim at providing more information, both quantitatively and qualitatively, on multiphase systems and their dynamics. The typical approach for such systems has been to carry out one local or bulk measurement and assume that this is representative of the whole system. In some cases, this is sufficient. However, there are many complex systems where the component distribution varies continuously and often unpredictably in space and time. The foundation of industrial tomography is to conduct several measurements around the periphery of a multiphase process, and use these measurements to unravel the cross-sectional distribution of the process components in time and space. This information is used in the design and optimization of industrial processes and process equipment, and also to improve the accuracy of multiphase system measurements in general. In this issue we are proud to present a selection of the 145 papers presented at the 5th World Congress on Industrial Process Tomography in Bergen

  15. Proton computed tomography

    International Nuclear Information System (INIS)

    Hanson, K.M.

    1978-01-01

    The use of protons or other heavy charged particles instead of x rays in computed tomography (CT) is explored. The results of an experimental implementation of proton CT are presented. High quality CT reconstructions are obtained at an average dose reduction factor compared with an EMI 5005 x-ray scanner of 10:1 for a 30-cm-diameter phantom and 3.5:1 for a 20-cm diameter. The spatial resolution is limited by multiple Coulomb scattering to about 3.7 mm FWHM. Further studies are planned in which proton and x-ray images of fresh human specimens will be compared. Design considerations indicate that a clinically useful proton CT scanner is eminently feasible

  16. The neutron computer tomography

    International Nuclear Information System (INIS)

    Matsumoto, G.; Krata, S.

    1983-01-01

    The method of computer tomography (CT) was applied for neutrons instead of X-rays. The neutron radiography image of samples was scanned by microphotometer to get the transmission data. This process was so time-consuming that the number of incident angles to samples could not be increased. The transmission data was processed by FACOM computer and CT image was gained. In the experiment at the Japan Research Reactor No. 4 at Tokai-mura with 18 projection angles, the resolution of paraffin in the aluminum block was less than 0.8 mm. In the experiment at Van de Graaf accelerator of Nagoya University, this same resolution was 1.2 mm because of the angle distribution of neutron beam. This experiment is the preliminary one, the facility which utilizes neutron television and video-recorder will be necessary for the next stage. (Auth.)

  17. Emission computed tomography

    International Nuclear Information System (INIS)

    Phelps, M.E.

    1977-01-01

    Although there are many common aspects to x-ray transmission and radionuclide emission (ECT) computerized tomography, there are added difficulties and a number of particular factors which form the basis of ECT. The relationship between the physical factors, system design, methodologic approach and assumptions of ECT is discussed. The instrumentation design and application strategies in ECT at this time are diverse and in a rapid stage of development. The approaches are divided into two major categories of Single Photon Counting (SPC) employing scanner and camera concepts with radionuclides of 99 /sup m/Tc, 201 Tl, 123 I etc., and Annihilation Coincidence Detection (ACD) of positron-emitting radionuclides. Six systems in the former and ten systems in the latter category, with examples of typical studies, illustrate the different approaches

  18. Tomography by positrons emission

    International Nuclear Information System (INIS)

    Mosconi, Sergio L.

    1999-01-01

    The tomography by positrons emission is a technology that allows to measure the concentration of positrons emission in a tri dimensional body through external measurements. Among the isotope emissions have carbon isotopes are ( 11 C), of the oxygen ( 15 O), of the nitrogen ( 13 N) that are three the element that constitute the base of the organic chemistry. Theses have on of the PET's most important advantages, since many biological interesting organic molecules can be tracer with these isotopes for the metabolism studies 'in vivo' through PET, without using organic tracers that modify the metabolism. The mentioned isotopes, also possess the characteristic of having short lifetime, that constitute on of PET's advantages from the dosimetric point of view. Among 11 C, 15 O, and 13 N, other isotopes that can be obtained of a generator as the 68 Ga and 82 Rb

  19. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  20. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    A positron emission tomography camera having a plurality of detector planes positioned side-by-side around a patient area to detect radiation. Each plane includes a plurality of photomultiplier tubes and at least two rows of scintillation crystals on each photomultiplier tube extend across to adjacent photomultiplier tubes for detecting radiation from the patient area. Each row of crystals on each photomultiplier tube is offset from the other rows of crystals, and the area of each crystal on each tube in each row is different than the area of the crystals on the tube in other rows for detecting which crystal is actuated and allowing the detector to detect more inter-plane slides. The crystals are offset by an amount equal to the length of the crystal divided by the number of rows. The rows of crystals on opposite sides of the patient may be rotated 90 degrees relative to each other

  1. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; O'Dell, W.R.; Brook, R.F.; Hein, P.W.; Brandt, R.T.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. A failsafe, solenoid brake is described which can lock the shaft against rotation. The gantry also contains a hoist mechanism which aids maintenance of the heavy X-ray tube and/or detector arrays. Explicit engineering details are presented. (U.K.)

  2. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    A positron emission tomography camera having a plurality of detector rings positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom. Each ring contains a plurality of scintillation detectors which are positioned around an inner circumference with a septum ring extending inwardly from the inner circumference along each outer edge of each ring. An additional septum ring is positioned in the middle of each ring of detectors and parallel to the other septa rings, whereby the inward extent of all the septa rings may be reduced by one-half and the number of detectors required in each ring is reduced. The additional septa reduces the costs of the positron camera and improves its performance

  3. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    A positron emission tomography camera having a plurality of detector rings positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom. Each detector ring or offset ring includes a plurality of photomultiplier tubes and a plurality of scintillation crystals are positioned relative to the photomultiplier tubes whereby each tube is responsive to more than one crystal. Each alternate crystal in the ring is offset by one-half or less of the thickness of the crystal such that the staggered crystals are seen by more than one photomultiplier tube. This sharing of crystals and photomultiplier tubes allows identification of the staggered crystal and the use of smaller detectors shared by larger photomultiplier tubes thereby requiring less photomultiplier tubes, creating more scanning slices, providing better data sampling, and reducing the cost of the camera. The offset detector ring geometry reduces the costs of the positron camera and improves its performance

  4. Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Fercher, A.F.; Andersen, Peter E.

    2017-01-01

    Optical coherence tomography (OCT) is a technique that is used to peer inside a body noninvasively. Tissue structure defined by tissue absorption and scattering coefficients, and the speed of blood flow, are derived from the characteristics of light remitted by the body. Singly backscattered light...... detected by partial coherence interferometry (PCI) is used to synthesize the tomographic image coded in false colors. A prerequisite of this technique is a low time-coherent but high space-coherent light source, for example, a superluminescent diode or a supercontinuum source. Alternatively, the imaging...... technique can be realized by using ultrafast wavelength scanning light sources. For tissue imaging, the light source wavelengths are restricted to the red and near-infrared (NIR) region from about 600 to 1300 nm, the so-called therapeutic window, where absorption (μa ≈ 0.01 mm−1) is small enough. Transverse...

  5. Projection radiography and tomography

    International Nuclear Information System (INIS)

    Tobias, C.A.; Fabrikant, J.I.; Benton, E.V.; Holley, W.R.

    1980-01-01

    Our program on heavy-ion radiography began soon after heavy ions were accelerated to high energies. Heavy ions are capable of very high electron density discrimination combined with good radial image resolution and low dose. Since heavy-ion beams produce many secondries, plastic nuclear detectors have an advantage for recording heavy-ion images. Projection imaging is now a practical technique that can resolve density differences between normal tissue and tumor tissue in some cases in which X rays could not make a distinction. Initial attempts at heavy-ion tomography also indicate potential for high resolution in this field. The physical basis for heavy-ion radiography and tomographic reconstruction studies are discussed in detail

  6. Waste Inspection Tomography (WIT)

    International Nuclear Information System (INIS)

    Bernardi, R.T.

    1995-01-01

    Waste Inspection Tomography (WIT) provides mobile semi-trailer mounted nondestructive examination (NDE) and assay (NDA) for nuclear waste drum characterization. WIT uses various computed tomography (CT) methods for both NDE and NDA of nuclear waste drums. Low level waste (LLW), transuranic (TRU), and mixed radioactive waste can be inspected and characterized without opening the drums. With externally transmitted x-ray NDE techniques, WIT has the ability to identify high density waste materials like heavy metals, define drum contents in two- and three-dimensional space, quantify free liquid volumes through density and x-ray attenuation coefficient discrimination, and measure drum wall thickness. With waste emitting gamma-ray NDA techniques, WIT can locate gamma emitting radioactive sources in two- and three-dimensional space, identify gamma emitting isotopic species, identify the external activity levels of emitting gamma-ray sources, correct for waste matrix attenuation, provide internal activity approximations, and provide the data needed for waste classification as LLW or TRU. The mobile feature of WIT allows inspection technologies to be brought to the nuclear waste drum storage site without the need to relocate drums for safe, rapid, and cost-effective characterization of regulated nuclear waste. The combination of these WIT characterization modalities provides the inspector with an unprecedented ability to non-invasively characterize the regulated contents of waste drums as large as 110 gallons, weighing up to 1,600 pounds. Any objects that fit within these size and weight restrictions can also be inspected on WIT, such as smaller waste bags and drums that are five and thirty-five gallons

  7. Ocean acoustic tomography

    International Nuclear Information System (INIS)

    Cornuelle, Bruce D; Worcester, Peter F; Dzieciuch, Matthew A

    2008-01-01

    Ocean acoustic tomography (OAT) was proposed in 1979 by Walter Munk and Carl Wunsch as an analogue to x-ray computed axial tomography for the oceans. The oceans are opaque to most electromagnetic radiation, but there is a strong acoustic waveguide, and sound can propagate for 10 Mm and more with distinct multiply-refracted ray paths. Transmitting broadband pulses in the ocean leads to a set of impulsive arrivals at the receiver which characterize the impulse response of the sound channel. The peaks observed at the receiver are assumed to represent the arrival of energy traveling along geometric ray paths. These paths can be distinguished by arrival time, and by arrival angle when a vertical array of receivers is available. Changes in ray arrival time can be used to infer changes in ocean structure. Ray travel time measurements have been a mainstay of long-range acoustic measurements, but the strong sensitivity of ray paths to range-dependent sound speed perturbations makes the ray sampling functions uncertain in real cases. In the ray approximation travel times are sensitive to medium changes only along the corresponding eigenrays. Ray theory is an infinite-frequency approximation, and its eikonal equation has nonlinearities not found in the acoustic wave equation. We build on recent seismology results (kernels for body wave arrivals in the earth) to characterize the kernel for converting sound speed change in the ocean to travel time changes using more complete propagation physics. Wave-theoretic finite frequency kernels may show less sensitivity to small-scale sound speed structure.

  8. Magnetic resonance tomography in syringomyelia

    International Nuclear Information System (INIS)

    Koehler, D.; Treisch, J.; Hertel, G.; Schoerner, W.; Fiegler, W.; Staedtisches Rudolf-Virchow Krankenhaus, Berlin

    1985-01-01

    Thirteen patients with a clinical diagnosis of syringomyelia were examined by nuclear tomography (0.35 T magnet) in the spin-echo mode. In all thirteen patients, the T1 images (Se 400/35) showed a longitudinal cavity with a signal intensity of CSF. The shape and extent of the syrinx could be adequately demonstrated in 12 of the 13 examinations. Downward displacement of the cerebellar tonsils was seen in eight cases. The examination took between half and one hour. Advantages of magnetic resonance tomography (nuclear tomography) include the absence of artifacts, images in the line of the lesion and its non-invasiveness. (orig.) [de

  9. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  10. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Disseminated Cryptococcosis.

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography-computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm.

  11. Parkinson disease and positron tomography

    International Nuclear Information System (INIS)

    Baron, J.C.

    1984-10-01

    Physiopathologic investigations of Parkinson disease and parkinsonian syndrome using positron tomography are briefly reviewed: study of cerebral blood flow and metabolism; effects of L-DOPA; study of dopaminergic receptors and of 18 F-Fluoro-L-DOPA incorporation [fr

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... is Children's CT? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... is used to evaluate: complications from infections such as pneumonia a tumor that arises in the lung ...

  13. Computed tomography of drill cores

    International Nuclear Information System (INIS)

    Taylor, T.

    1985-08-01

    A preliminary computed tomography evaluation of drill cores of granite and sandstone has generated geologically significant data. Density variations as small as 4 percent and fractures as narrow as 0.1 mm were easily detected

  14. Computed tomography of pulmonary nodules

    International Nuclear Information System (INIS)

    Nakata, Hajime; Honda, Hiroshi; Nakayama, Chikashi; Kimoto, Tatsuya; Nakayama, Takashi

    1983-01-01

    We have evaluated the value of computed tomography (CT) in distinguishing benign and malignant pulmonary nodules. CT was performed on 30 cases of solitary pulmonary nodules consisting of 17 primary lung cancers, 3 metastatic tumors and 10 benign nodules. The CT number was calculated for each lesion. Three benign nodules showed CT numbers well above the range of malignant nodules, and only in one of them was calcification visible on conventional tomography. In 6 benign nodules, the CT numbers overlapped those of malignant lesion and could not be differentiated. Thus the measurement of CT number can be useful to confirm the benign nature of certain nodules when calcification is unclear or not visible on conventional tomography. As for the morphological observation of the nodule, CT was not superior to conventional tomography and its value seems to be limited. (author)

  15. Parsimonious Refraction Interferometry and Tomography

    KAUST Repository

    Hanafy, Sherif; Schuster, Gerard T.

    2017-01-01

    We present parsimonious refraction interferometry and tomography where a densely populated refraction data set can be obtained from two reciprocal and several infill shot gathers. The assumptions are that the refraction arrivals are head waves

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Children's (Pediatric) CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  17. A Sintaxe da Janela

    Directory of Open Access Journals (Sweden)

    Luís Antônio Jorge

    1993-12-01

    Full Text Available A preocupação fundamenta! do trabalho é de caráter ontológico: esboçar o problema das significações apriorísticas e autônomas dos elementos que compõem a sintaxe arquitetônica. O trabalho elege um desses elementos: a janela. Este artigo parte da aproximação histórica entre a janela e a secção da pirâmide visual, construção imaginária da teoria da perspectiva renascentista. A consideração da janela na linguagem arquitetônica implica reconhecer uma ambigüidade essencial: a janela deve inserir-se ordenadamente no plano da parede - raciocínio típico da modenatura - mas também relacionar-se com a imagem vista através dela, que extrapola o plano, ressaltando a tridimensionalidade - herança da perspectiva renascentista, fundamentada no espaço euclidiano. Ver janela ou ver através da janela são alternativas que se colocam tanto ao observador interno ao edifício, quanto ao externo. Texto de duplaface, a sintaxe da janela versa sobre o relacionamento desses dois lados

  18. Computerized tomography in myotonic dystrophy

    International Nuclear Information System (INIS)

    Gellerich, I.; Mueller, D.; Koch, R.D.

    1986-01-01

    Besides clinical symptoms, progress and electromyography computerized tomography improves the diagnostics of myotonic dystrophy. Even small changes in muscular structure are detectable and especially the musculus soleus exhibits early and pronounced alterations. By means of density distribution pattern an improved characterization of the disease is possible. Additional information is obtained by cerebral computerized tomography. Atrophy of brain tissue is to be expected in all patients with myotonic dystrophy. (author)

  19. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  20. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Kretschmann, H.J.; Weinrich, W.

    1985-01-01

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  1. Intussusception in children: imaging evaluation and therapeutic approach; Intussuscepcao em criancas: avaliacao por metodos de imagem e abordagem terapeutica

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, Fabio Motta da; Figueiredo, Sizenildo da Silva; Nobrega, Bruno Barcelos da; Monteiro, Soraya Silveira; Lederman, Henrique Manoel [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. de Diagnostico por Imagem]. E-mail: brunoradiol@hotmail.com; Oliveira, Galba Leite [Irmandade Santa Casa de Misericordia de Sao Paulo, SP (Brazil). Dept. de Diagnostico por Imagem

    2005-05-15

    Intussusception is a medical emergency that occur with higher frequency in children under 2 years of age. Diagnosis can be difficult as the classical triad of abdominal pain, jelly stools and palpable abdominal mass is seen in less than 50% of the patients. However, the diagnosis of intussusception can be established with variable degree of accuracy using plain abdominal x-ray films, ultrasound, computed tomography or barium (or air/saline) enema. Some of these imaging methods are also useful during treatment of this condition. The authors present a review of the literature and a pictorial essay of the imaging findings in patients with intussusception. In addition, a discussion on the current and controversial issues related to the treatment of intussusception is presented. (author)

  2. Computed tomography apparatus

    International Nuclear Information System (INIS)

    Fairbairn, I.A.

    1984-01-01

    In fan-beam computed tomography apparatus, timing reference pulses, normally occurring at intervals t, for data transfer and reset of approx. 500 integrators in the signal path from the detector array, are generated from the scan displacement, e.g. using a graticule and optical sensor to relate the measurement paths geometrically to the body section. Sometimes, a slow scan rate is required to provide a time-averaged density image, e.g. for planning irradiation therapy, and then the sensed impulses will occur at extended intervals and can cause integrator overload. An improvement is described which provides a pulse generator which responds to a reduced scan rate by generating a succession of further transfer and reset pulses at intervals approximately equal to t starting a time t after each timing reference pulse. Then, using an adding device and RAM, all the transferred signals integrated in the interval t' between two successive slow scan reference pulses are accumulated in order to form a corresponding measurement signal. (author)

  3. Solar tomography adaptive optics.

    Science.gov (United States)

    Ren, Deqing; Zhu, Yongtian; Zhang, Xi; Dou, Jiangpei; Zhao, Gang

    2014-03-10

    Conventional solar adaptive optics uses one deformable mirror (DM) and one guide star for wave-front sensing, which seriously limits high-resolution imaging over a large field of view (FOV). Recent progress toward multiconjugate adaptive optics indicates that atmosphere turbulence induced wave-front distortion at different altitudes can be reconstructed by using multiple guide stars. To maximize the performance over a large FOV, we propose a solar tomography adaptive optics (TAO) system that uses tomographic wave-front information and uses one DM. We show that by fully taking advantage of the knowledge of three-dimensional wave-front distribution, a classical solar adaptive optics with one DM can provide an extra performance gain for high-resolution imaging over a large FOV in the near infrared. The TAO will allow existing one-deformable-mirror solar adaptive optics to deliver better performance over a large FOV for high-resolution magnetic field investigation, where solar activities occur in a two-dimensional field up to 60'', and where the near infrared is superior to the visible in terms of magnetic field sensitivity.

  4. Positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lindback, Stig [GEMS PET Systems AB, Uppsala (Sweden)

    1995-07-15

    Positron Emission Tomography (PET) is an advanced nuclear medicine technique used for research at major centres. Unique diagnostic information is obtained from tomographic measurements of the biochemistry and physiology of tissues and organs. In theory, diseases are related to biochemical changes and these can be observed with PET long before any anatomical changes are detectable. In PET the radioactive component is a positron-emitting isotope or 'tracer'. The positrons annihilate with electrons in the body to produce two gamma rays 180° apart; coincidence detection of these gammas provides a very efficient method of determining the spatial distribution of the radioisotope tracer. Because physiological measurements are usually required in a single imaging session, very short-lived isotopes are used to label the tracer molecules; isotope production and labelling is usually carried out in situ. The most commonly used radionuclides are carbon- 11 (half-life 20 minutes), nitrogen-13 (10 minutes), oxygen-15 (2 minutes), and fluorine-18 (110 minutes). A PET system has three major components: - a particle accelerator with targets for production of the positron-emitting isotopes; - chemistry modules for synthesis and labelling of the desired tracers; - and a PET camera for in-vivo measurements of the distribution of the tracer in the body.

  5. Positron emission tomography

    International Nuclear Information System (INIS)

    Lindback, Stig

    1995-01-01

    Positron Emission Tomography (PET) is an advanced nuclear medicine technique used for research at major centres. Unique diagnostic information is obtained from tomographic measurements of the biochemistry and physiology of tissues and organs. In theory, diseases are related to biochemical changes and these can be observed with PET long before any anatomical changes are detectable. In PET the radioactive component is a positron-emitting isotope or 'tracer'. The positrons annihilate with electrons in the body to produce two gamma rays 180° apart; coincidence detection of these gammas provides a very efficient method of determining the spatial distribution of the radioisotope tracer. Because physiological measurements are usually required in a single imaging session, very short-lived isotopes are used to label the tracer molecules; isotope production and labelling is usually carried out in situ. The most commonly used radionuclides are carbon- 11 (half-life 20 minutes), nitrogen-13 (10 minutes), oxygen-15 (2 minutes), and fluorine-18 (110 minutes). A PET system has three major components: - a particle accelerator with targets for production of the positron-emitting isotopes; - chemistry modules for synthesis and labelling of the desired tracers; - and a PET camera for in-vivo measurements of the distribution of the tracer in the body

  6. Computed tomography intravenous cholangiography

    International Nuclear Information System (INIS)

    Nascimento, S.; Murray, W.; Wilson, P.

    1997-01-01

    Indications for direct visualization of the bile ducts include bile duct dilatation demonstrated by ultrasound or computed tomography (CT) scanning, where the cause of the bile duct dilatation is uncertain or where the anatomy of bile duct obstruction needs further clarification. Another indication is right upper quadrant pain, particularly in a post-cholecystectomy patient, where choledocholithiasis is suspected. A possible new indication is pre-operative evaluation prior to laparoscopic cholecystectomy. The bile ducts are usually studied by endoscopic retrograde cholangiopancreatography (ERCP), or, less commonly, trans-hepatic cholangiography. The old technique of intravenous cholangiography has fallen into disrepute because of inconsistent bile-duct opacification. The advent of spiral CT scanning has renewed interest in intravenous cholangiography. The CT technique is very sensitive to the contrast agent in the bile ducts, and angiographic and three-dimensional reconstructions of the biliary tree can readily be obtained using the CT intravenous cholangiogram technique (CT IVC). Seven patients have been studied using this CT IVC technique, between February 1995 and June 1996, and are the subject of the present report. Eight further studies have since been performed. The results suggest that CT IVC could replace ERCP as the primary means of direct cholangiography, where pancreatic duct visualization is not required. (authors)

  7. Multiphoton tomography of astronauts

    Science.gov (United States)

    König, Karsten; Weinigel, Martin; Pietruszka, Anna; Bückle, Rainer; Gerlach, Nicole; Heinrich, Ulrike

    2015-03-01

    Weightlessness may impair the astronaut's health conditions. Skin impairments belong to the most frequent health problems during space missions. Within the Skin B project, skin physiological changes during long duration space flights are currently investigated on three European astronauts that work for nearly half a year at the ISS. Measurements on the hydration, the transepidermal water loss, the surface structure, elasticity and the tissue density by ultrasound are conducted. Furthermore, high-resolution in vivo histology is performed by multiphoton tomography with 300 nm spatial and 200 ps temporal resolution. The mobile certified medical tomograph with a flexible 360° scan head attached to a mechano-optical arm is employed to measure two-photon autofluorescence and SHG in the volar forearm of the astronauts. Modification of the tissue architecture and of the fluorescent biomolecules NAD(P)H, keratin, melanin and elastin are detected as well as of SHG-active collagen. Thinning of the vital epidermis, a decrease of the autofluoresence intensity, an increase in the long fluorescence lifetime, and a reduced skin ageing index SAAID based on an increased collagen level in the upper dermis have been found. Current studies focus on recovery effects.

  8. Electrical impedance tomography

    Science.gov (United States)

    Lobo, Beatriz; Hermosa, Cecilia; Abella, Ana

    2018-01-01

    Continuous assessment of respiratory status is one of the cornerstones of modern intensive care unit (ICU) monitoring systems. Electrical impedance tomography (EIT), although with some constraints, may play the lead as a new diagnostic and guiding tool for an adequate optimization of mechanical ventilation in critically ill patients. EIT may assist in defining mechanical ventilation settings, assess distribution of tidal volume and of end-expiratory lung volume (EELV) and contribute to titrate positive end-expiratory pressure (PEEP)/tidal volume combinations. It may also quantify gains (recruitment) and losses (overdistention or derecruitment), granting a more realistic evaluation of different ventilator modes or recruitment maneuvers, and helping in the identification of responders and non-responders to such maneuvers. Moreover, EIT also contributes to the management of life-threatening lung diseases such as pneumothorax, and aids in guiding fluid management in the critical care setting. Lastly, assessment of cardiac function and lung perfusion through electrical impedance is on the way. PMID:29430443

  9. Evaluation of the efficiency of a tubular digester in the reduction of organic load of biogas from swine wastes; Avaliacao da eficiencia de um biodigestor tubular na reducao da carga organica de biogas a partir de dejetos de suinos

    Energy Technology Data Exchange (ETDEWEB)

    Angonese, Andre Ricardo [Universidade Estadual do Oeste do Parana (UNIOESTE), PR (Brazil)], Email: aangonese@yahoo.com.br; Campos, Alessandro Torres [Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Diamantina, MG (Brazil)], Email: atcampos3@yahoo.com.br; Moreno Palacio, Soraya [Universidade Estadual de Maringa (UEM), PR (Brazil); Szymanski, Nayara [Universidade Estadual do Oeste do Parana (UNIOESTE), PR (Brazil). Curso de Quimica

    2006-07-01

    The purpose of this study was to assess the efficiency of the anaerobic biological treatment systems in the reduction and stabilization of biodegradable organic matter of swine waste. The experiment was carried out at Vale dos Ipes Farm, located in the city of Ouro Verde do Oeste, in the Western of Parana State. One finishing phase swine unity containing 600 animals was monitored from January to June 2005. The system is composed by one steel digester with capacity for 50 m{sup 3}. The swine barn cleaning is performed by dry scratching on a daily basis. The generated residues flow by gravitation through ducts towards the digester. The duration of the hydraulic retention period was 12 days. The residues analysis was performed by means of sampling at the entrance and way out of the digester. The following parameters were analyzed: pH, DBO{sub 5}, DQO, total solids, total volatile solids, total fixed solids, total nitrogen e ammonia, potassium, total phosphate, average of biogas production. The results suggested that the anaerobic biological treatment system was efficient for reducing and stabilizing the organic matter resulted from the swine wastes. Expressive reductions of DBO, DQO, ST and SVT of 76, 77, 43 and 59% respectively, were obtained for the effluent originated by the digester. The average daily production of biogas during the analyzed period was 31, 5 m{sup 3}. (author)

  10. Evaluation of the effects of gamma radiation in minimally processed vegetables of Brassica oleracea species; Avaliacao dos efeitos da radiacao gama em vegetais da especie Brassica oleracea minimamente processados

    Energy Technology Data Exchange (ETDEWEB)

    Nunes, Thaise Cristine Fernandes

    2009-07-01

    The consumption of collard greens (Brassica oleracea cv. acephala) and broccoli (Brassica oleracea L. var. italica) has been inversely associated with morbidity and mortality caused by degenerative diseases. These species are highly consumed in Brazil, which enables its use as minimally processed (MP). The growing worldwide concern with the storage, nutritional quality and microbiological safety of food has led to many studies aimed at microbiological analysis, vitamin and shelf life. To improve the quality of these products, radiation processing can be effective in maintaining the quality of the product, rather compromising their nutritional values and sensory. The aim of this study was to evaluate the effectiveness of gamma radiation from {sup 60}Co at doses of 0, 1.0 and 1.5 kGy on the reduction of microbiota in these plants, and analyze their nutritional and sensory characteristics. The methodology used in this study was microbiological analysis, colorimetric analysis, analysis of phenolic compounds, antioxidant analysis and sensory analysis. The microbiological analysis showed a decrease in the development of populations of aerobic microorganisms, psychotropic and yeast and mold with increasing doses of radiation. The sensory analysis showed no significant difference between different times of cooking analyzed. The analysis of phenolic compounds, significant differences between the samples, suggesting that with increasing dose of irradiation was an increase in the amount of phenolic compounds found in broccoli and collard greens MP. It can be observed that the sample of control collard greens showed high antioxidant activity and for the samples treated by irradiation was a decrease of percentage. In contrast the samples of broccoli show an increase in the rate of scavenging DPPH with increase of the dose of radiation. The colorimetric analysis revealed that for samples of MP collard greens and broccoli foil of no significant differences, but for samples of stems of broccoli significant difference on the yellowing during storage. It is concluded that the processing of collard greens and broccoli butter by gamma radiation may be a viable alternative to the industry, since there was a reduction of the population of microorganisms, without changes in the sensory qualities and with minimum changes in the characteristics that confer antioxidant power. (author)

  11. Evaluation of toxicity and removal of color in textile effluent treated with electron beam; Avaliacao da toxicidade e remocao da cor de um efluente textil tratado com feixe de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Morais, Aline Viana de

    2015-07-01

    The textile industry is among the main activities Brazil, being relevant in number of jobs, quantity and diversity of products and mainly by the volume of water used in industrial processes and effluent generation. These effluents are complex mixtures which are characterized by the presence of dyes, surfactants, metal sequestering agents, salts and other potentially toxic chemicals for the aquatic biota. Considering the lack of adequate waste management to these treatments, new technologies are essential in highlighting the advanced oxidation processes such as ionizing radiation electron beam. This study includes the preparation of a standard textile effluent chemical laboratory and its treatment by electron beam from electron accelerator in order to reduce the toxicity and intense staining resulting from Cl. Blue 222 dye. The treatment caused a reduction in toxicity to exposed organisms with 34.55% efficiency for the Daphnia similis micro crustacean and 47.83% for Brachionus plicatilis rotifer at a dose of 2.5 kGy. The Vibrio fischeri bacteria obtained better results after treatment with a dose of 5 kGy showing 57.29% efficiency. Color reduction was greater than 90% at a dose of 2.5 kGy. This experiment has also carried out some preliminary tests on the sensitivity of the D. similis and V. fischeri organisms to exposure of some of the products used in this bleaching and dyeing and two water reuse simulations in new textile processing after the treating the effluent with electron beam. (author)

  12. Evaluation of synergistic effect in vacuum pack, refrigeration and irradiated treatments of minimally processed cassava; Avaliacao do efeito sinergistico da embalagem a vacuo, irradiacao e refrigeracao da mandioca minimamente processada

    Energy Technology Data Exchange (ETDEWEB)

    Pedroso, Bianca Maria

    2005-07-01

    Cassava is cultivated almost all over the world and it is considered one of the most important nutritious sources of calories in the human diet. Cassava is a viable food against starvation in several poor areas of the world because it is an extremely resistant culture and may reach satisfactory economical yield. We utilized vacuum packed industrialized cassava irradiated with 0,1 kGy, 3kGy and 5kGy and stored under refrigeration for 1, 21, 30 and 50 days. Our objective was to analyse the synergistic effect of vacuum packing, irradiation and refrigeration on the preservation of minimally processed cassava. The samples were analyzed for pH, acidity, weight, humidity, texture and color. The irradiation did not affect the chemical characteristics of the cassava. Neither the pH nor the acidity, the most relevant variables to verify deterioration in cassava, presented significant alterations during the period of storage. Comparing the irradiated treatments, the dose of 1kGy and 3kGy affected the physic-chemical characteristics of the cassava the least during the period of storage and refrigeration for 50 days; the doses of 1kGy,3kGy and 5kGy scored the highest rates the sensorial analysis during the period of storage for 21 days. (author)

  13. Social environmental and economic evaluation diagnosis through application of MADSA (Social and Environmental Evaluation Matrix) customization; Diagnostico de desempenho socioambiental e economico por meio da customizacao da MADSA (Matriz para Avaliacao de Desempenho Socioambiental)

    Energy Technology Data Exchange (ETDEWEB)

    Ziliotto, Marco Aurelio B.; Villa, Alessandra T.; Padilha, Simone L. Vieira; Canaverde, Patricia Margue [Instituto ECOPLAN, General Carneiro, PR (Brazil); Sanqueta, Carlos Roberto [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil)

    2004-07-01

    The present paper reports a social, environment and economic diagnosis in an oil and energy organization, in the enlargement of its plant. Attending to some previous requirements made by this company, the diagnosis was accomplished making use of an innovative evaluation tool called MADSA{sup R} (Social and Environmental Evaluation Matrix). Through the customization of this tool, it was possible to evaluate, systematically, the performance of the engaged companies hired by the organization to implement its enterprise, based on proposed actions in QSMS - Quality, Safety, Environment and Health. The performance evaluation was supported by the employees', the organization, its clients' and the local community perception. MADSA{sup R} methodology made it possible to measure the accomplished gain through proposed actions. The development of a performance indicator allowed the comparison between achieved results and accomplished investments. It was concluded that MADSA{sup R} provided subsidies to elaborate an action plan to improve the organization achievements, since it was able to represent the strategy of the organization, to guide and standardize actions, to identify and quantify points to be made better of. (author)

  14. Evaluation of the potentiality of the use of high-carbon microsilica as a pozzolanic material; Avaliacao da potencialidade da utilizacao de microssilica de alto teor de carbono como material pozolanico

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, R.L.S.; Pederneiras, C.M.; Costa, T.C.S.; Silva, C.H.R.B., E-mail: ruan_landolfo@hotmail.com [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil); Anjos, M.A.S. [Instituto Federal da Paraiba (IFPB), PB (Brazil); Nobrega, A.K. [Universidade Federal Rural do Semi-Arido (UFERSA), Mossoro, RN (Brazil)

    2016-07-01

    Supplementary Cementitious Materials reduce the production of clinker, which minimizes the environmental impact of cement production and the generation of industrial waste, also improve mechanical behavior and durability. Thus, this article aims to evaluate the potential use of microsilica with high content of carbon as pozzolanic material, based on the requirements of ISO 12653 (ABNT, 2015). The techniques of X-ray fluorescence (XRF), X-ray diffraction (XRD) and compressive strength of mortar of lime and cement (at 7 and 28 days, respectively) were used to evaluate the pozzolanic of the microsilica as a mineral addition. The results indicated that the microsilica has a high amorphous silicon dioxide percentage structure. In the DRX could be possible to analyze the formation of CSH, justifying the good results of mechanical strength, especially with cement. Thus, the mineral admixture used in this research can be considered as a pozzolanic material. (author)

  15. Calculation of the uncertainty of H{sub P} (10) evaluation for a thermoluminescent dosimetry system; Calculo da incerteza da avaliacao do H{sub P} (10) para um sistema de dosimetria termoluminescente

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, M.S.; Silva, E.R.; Mauricio, C.L.P., E-mail: max.das.ferreira@gmail.com [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2016-07-01

    Full interpretation of dose assessment only can be performed when the uncertainty of the measurement is known. The aim of this study is to calculate the uncertainty of the TL dosimetry system of the LDF/IRD for evaluation of H{sub P} (10) for photons. It has been done by experimental measurements, extraction of information from documents and calculation of uncertainties based on ISO GUM. Energy and angular dependence is the most important source to the combined u{sub c}(y) and expanded (U) uncertainty. For 10 mSv, it was obtained u{sub c}(y) = 1,99 mSv and U = 3,98 mSv for 95% of coverage interval. (author)

  16. Evaluation of oil and grease removal by adsorptive polymeric resins in semi-industrial scale: influence of temperature; Avaliacao da remocao de oleos e graxas por resinas polimericas adsorventes em escala semi-industrial: influencia da temperatura

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Luis F.S. de; Silva, Carla M.F. da; Queiros, Yure G.C.; Lucas, Elizabete F. [Universidade Federal do Rio de Janeiro, Instituto de Macromoleculas, Laboratorio de Macromoleculas e Coloides na Industria de Petroleo, Rio de Janeiro, RJ (Brazil)], e-mail: elucas@ima.ufrj.br

    2011-07-01

    The aim of this study was to evaluate the performance of polymeric resins packed in a fixed bed eluted in semi-industrial scale for oil and greases removal disposed in synthetic oily water in different temperature conditions. For this work, columns packed with vinyl and acryl polymer-base were tested and their efficiency of oil removal was evaluated by fluorimetry technique in two different temperatures: 25 and 60 deg C, in a flow rate condition of 200 mL/min. The experimental results were very good: the removal efficiencies were above 98% in both cases. At 60 deg C, the system keep the efficiency for a longer time: no significant loss in the efficiency was observed after eluting 1,000 times of the column bed volume at 25 deg C and 2,000, at 60 deg C. This result characterizes a great potential of application in the industry. (author)

  17. Resistance evaluation expanded perlite the leaching acid: variation of parameters concentration, time and leaching agent; Avaliacao da resistencia da perlita expandida a lixiviacao acida: variacao dos parametros concentracao, tempo e agente lixiviante

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, J.M.F. de; Damasceno Junior, E.; Oliveira, E.S.; Fernandes, N.S., E-mail: janielequimicaufrn@gmail.com [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Instituto de Quimica. Laboratorio de Quimica Analitica e Meio Ambiente

    2016-07-01

    The expanded perlite is an amorphous aluminosilicate which presents in its composition about 75.0% silicon oxide (SiO2), also having other species in the composition as oxides of some metals. Silicas and silicates have been used in the environmental field, in relevant anti-corrosive activity. In this context, materials that exposes too many highly acidic media, require preservation against this type of wear, as this type of damage causes a great financial loss, thereby requiring low-cost, abundant materials, non-toxic and easy to purchase as some silica coating. The study evaluated the perlite expanded resistance against an acid leaching process. With undeniability the use of strong acids and different working conditions were not able to remove the oxides present on the expanded perlite sample, thus demonstrating the high strength of the expanded perlite against acid attacks. (author)

  18. Evaluation of internal occupational exposure of workers from nuclear medicine services by aerosol analysis containing {sup 131}I; Avaliacao da exposicao interna de trabalhadores em servicos de medicina nuclear atraves da analise de aerossois contendo {sup 131}I

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Luana Gomes; Sampaio, Camilla da Silva; Dantas, Ana Leticia Almeida; Lucena, Eder Augusto; Santos, Maristela Souza; Dantas, Bernardo Maranhao, E-mail: carneiro@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ),Rio de Janeiro, RJ (Brazil); Paula, Gustavo Affonso de [Escola SESC de Ensino Medio, Rio de Janeiro, RJ (Brazil)

    2014-07-01

    This study evaluated the risk of internal occupational exposure associated with the incorporation of {sup 131}I via inhalation, in Nuclear Medicine Services, using aerosol analysis techniques. Occupationally Exposed Individuals (IOE) involved in handling this radionuclide are subject to chronic exposure, which can lead to an increase in the committed effective dose. Results obtained in preliminary studies indicate the occurrence of incorporation of {sup 131}I by workers involved in handling solutions for radioiodine therapy procedures. The evaluation was carried out in radiopharmacy lab (nuclear medicine service) of a public hospital located in the city of Rio de Janeiro. After confirmed the presence of the radioisotope, by a qualitative assessment, it was determined an experimental arrangement for sample collection and were detected and quantitated the presence of steam {sup 131}I during routine work. The average concentration of activity obtained in this study was 3 Bq / m{sup 3}. This value is below of Derived Concentration in Air (DCA) of 8.4 x 10{sup 3} Bq of {sup 131}I / m{sup 3} corresponding to a committed effective dose of 1.76 x 10{sup -4} mSv. These results demonstrate that the studied area is safe in terms of internal exposure of workers. However, the presence of {sup 131}I should be periodically reevaluated, since this type of exposure contributes to the increase of the individual effective doses. Based on the data obtained improvements were suggested in the exhaust system and the use of good work practices in order to optimize the exposures.

  19. Preliminary analysis of doses to evaluate the image quality in radiographic examinations in veterinary radiology;Analise preliminar das doses para avaliacao da qualidade da imagem em exames radiograficos na radiologia veterinaria

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Ana Carolina B.C.F.; Dias, Mayara T.P.; Santos, Andrea C. [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia; Melo, Camila S.; Furquim, Tania A.C. [Universidade de Sao Paulo (IEE/USP), SP (Brazil). Inst. de Eletrotecnica e Energia

    2009-07-01

    This work has as objective to promote the analysis of the radiological doses and quality of the image of the technical letter used for the accomplishment of thorax and coxal radiographic examination of animals of canine and feline species. The study was accomplished in the service of Diagnosis for Image in Veterinarian Hospital of Veterinary Medicine and Zootecnia College of University of Sao Paulo, in two conventional equipment. Initially, physical features of the animals and the technique used were collected for each one of the 188 radiographic examinations of thorax and 52 examinations of coxal. The animals were placed in different groups, according to their body weight. For each group, the averages for each feature were calculated: thickness of the radiographed region, tension, electric current, time of exhibition, current product electric-time, size of the used film, presence or absence of bucky and feature of focus (narrow or thick). On the basis of the averages of group M (of lesser weights that 5kg for cats and between 10,1kg and 20kg for dogs), was executed a physical analysis of the current technical letter, using the equipment: ionization chamber (to determinate the value of kerma in air), simulator objects (representative of the thickness of the animal) and three dispositive standards of test that evaluate space resolution, resolution in low contrast and contrast-detail. The obtained images were analyzed and compared for a physicist and a radiologist medical veterinary. The results had shown that the examinations supply dose considered high for techniques used mainly for coxal. The equipment A, although to supply higher doses, presents the better images for the majority of the projections. However, the study indicates that there are not exactly reference levels, but these examinations must pass for improvement of quality of image (author)

  20. In vitro assessment of the composition and microhardness of hard tissues of oral cavity submitted to gamma irradiation; Avaliacao in vitro da composicao e microdureza dos tecidos duros da cavidade bucal submetidos a irradiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Paredes, Wilber Edison Bernaola

    2017-11-01

    Clinical Radiotherapy is extremely important for the treatment of malignant lesions of the head and neck region, however, exposure to ionizing radiation can lead to systemic or local complications during and after radiation treatment. Among these immediate local complications are the oral cavity xerostomia and the consequent oral mucositis. Regarding late complications produced by radiation, tooth decay of radiation and osteoradionecrosis are included, which are considered dose-dependent lesions, with high incidence in recent decades and difficult to manage, although these appear after completion of treatment and under the influence of local factors. The methodology proposed in this study consists in evaluating the effect of gamma radiation after irradiation of the samples, using the dose used in patients suffering with head and neck cancer. The samples were obtained from human enamel and root dentin; and swine mandibular bone, which were previously polished, and then submitted to the analysis of the initial surface microhardness of all groups. Subsequently, the samples were irradiated in a dose rate of 4 Gy per day, completing a total dose of 72 Gy. Finally, the samples were submitted to surface microhardness analysis after irradiation, which presented statistically significant results from the Student t, ANOVA and Tukey statistical tests referred to the difference of the mean of the initial and final values of each study group with a significant value of p = 0.00 (<0.05). Regarding the morphological analysis in scanning electron microscopy (SEM), the deleterious effect of gamma irradiation was evidenced as structural cracks, breaks and superficial fractures of the analyzed tissues and the biochemical analysis by Attenuated Total Reflection technique using Fourier transform infrared spectroscopy (ATR - FTIR) showed degradation of inorganic components and denaturation of organic compounds; whereby, the effect of gamma irradiation on the hard tissues of the oral cavity with respect to mechanical, compositional and morphological properties was deleterious and this study highlighted the isolated action of this ionizing radiation which contributes highly for its appearance, independent of local and systemic factors in the irradiated patients. (author)

  1. The refractometry use in the evaluation of type 'C' gasoline non-conformities; Uso da refratometria na avaliacao de nao conformidades da gasolina tipo 'C'

    Energy Technology Data Exchange (ETDEWEB)

    Santos, K.M.; Andrade, J.M.; Severiano, M.L.; Medeiros, M.A.O.; Fernandes, N.S.; Fernandes, V.J. [Rio Grande do Norte Univ., Natal, RN (Brazil)]. E-mail: klecia.morais@bol.com.br

    2003-07-01

    The need of the creation of practical and efficient methods that can monitor the quality of the automotive fuels it is an important factor, because they should evaluate the physical-chemical properties of the fuels to guarantee your conformity. To determine these parameters of conformity, several regulars analyses are done in the gasoline type 'C', as the distillation and content of ethyl alcohol (AEAC). However, the present work has as objective uses the refractometry in the forecast of irregularities in the gasoline trying to establish a faster and efficient analysis method. (author)

  2. Evaluation of the effects resulting from the application of magnetic fields on the properties of crude oils and paraffins; Avaliacao da influencia da aplicacao de campos magneticos sobre as propriedades de petroleo e parafinas

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Lenise Couto; Rocha, Nelson de Oliveira; Dittz, Carlos Henrique da Silva [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES). Setor de Tecnologia de Processamento e Transporte

    2000-03-01

    In petroleum industry the phenomenon of build-up of organic deposits, basically of paraffinic nature, into surface equipment, flow lines and columns has been one of the greatest problems concerning the production and transfer of crude oils, leading to significant and increasing losses in production. The approach through the application of magnetic field is a novel technique, neither explained nor exploited altogether, not one that turns out to be a simple preventive solution for the problem requiring low investment and showing expressive benefits, provided its effectiveness is confirmed. The main results of laboratory test where the effects of application of magnetic fields on the properties of two crude oil types, one mixture of paraffins and two reference solution were evaluated are presented herein, and this paper also approaches the influence of process variables (Magnetization temperature, exposure time and magnetic field density) on the efficiency of this process of treatment. (author)

  3. Evaluation of the mineralogical characterization of several smectite clay deposits of the state of Paraiba, Brazil using statistical analysis of variance; Avaliacao da caracterizacao mineralogica de diversos depositos de argilas esmectiticas do estado da Paraiba utilizando analise estatistica de variancia

    Energy Technology Data Exchange (ETDEWEB)

    Gama, A.J.A.; Menezes, R.R.; Neves, G.A.; Brito, A.L.F. de, E-mail: agama@reitoria.ufcg.edu.br [Universidade Federal de Campina Grande (UFCG), PB (Brazil)

    2015-07-01

    Currently over 80% of industrialized bentonite clay produced in Brazil in sodium form for use in various industrial applications come from the deposits in Boa Vista - PB. Recently they were discovered new bentonite deposits situated in the municipalities of Cubati - PB, Drawn Stone - PB, Sossego - PB, and last in olive groves - PB, requiring systematic studies to develop all its industrial potential. Therefore, this study aimed to evaluate chemical characterization several deposits of smectite clays from various regions of the state of Paraíba through the analysis of statistical variance. Chemical analysis form determined by fluorescence x-ray (EDX). Then analyzes were carried out of variance statistics and Tukey test using the statistical soft MINITAB® 17.0. The results showed that the chemical composition of bentonite clay of new deposits showed different amounts of silica, aluminum, magnesium and calcium in relation clays in Boa Vista, and clays imported. (author)

  4. Model for qualitative evaluation of risk in ducts through the fuzzy logic in conformity with the methodology of IBR; Modelo para avaliacao qualitativa do risco em oleodutos atraves da logica fuzzy segundo a metodologia da IBR

    Energy Technology Data Exchange (ETDEWEB)

    Mishina, Koje Daniel Vasconcelos [Centro Federal de Educacao Tecnologica da Bahia (CEFET-BA), Salvador, BA (Brazil); Silva, Jose Felicio da; Silva, Joao Bosco de Aquino [Universidade Federal da Paraiba (UFPb), Joao Pessoa, PB (Brazil)

    2006-07-01

    This work considers a system for qualitative evaluation of the terrestrial risk in pipelines, based in the methodology of the Inspection Based on Risk and the Fuzzy Logic. For this one developed a matrix of risk associated with the oil transport and its derivatives, that define the type of tracking and the regularity of inspection with Pig Instrumented in function of the level of risk found in the stretch in study. This matrix of risk considers the probabilities and the consequences associates to the damage for corrosion. The evaluation of the considered system was based on the consistency of the found levels of risk, in relation to that it would be found in the practical one. The gotten results had demonstrated that the use of the methodology of the IBR and the Fuzzy Logic can be used jointly as one sufficiently efficient alternative technique in the evaluation of risk in corroded pipe-lines. (author)

  5. Environmental analysis of the proton exchange membrane fuel cell on the subject of life cycle assessment; Analise ambiental da celula a combustivel de membrana trocadora de protons sob o enfoque da avaliacao do ciclo de vida

    Energy Technology Data Exchange (ETDEWEB)

    Fukurozaki, Sandra Harumi

    2006-07-01

    The energy is the fuel of growth and an essential requirement for the socioeconomic development. However, the current production model is based on fossil fuels, considered as threat to man and nature. As for, the relating to the human activities and their effects on the environment, they are handled by the implementation of a more rigid model of environmental control and the mobilization of the society in favor of technologies with less energy impact. In view of this scenario, the Proton Exchange Membrane Fuel Cell - PEMFC has been recognized as a key for the vital need of a clean and efficient energy. Considering the conventional power generation system, their advantages during usage configure its application as an ideal option for several utilities, especially in the mobile sector. Even though, the focus on several environmental evaluations in energy systems is referred back to the initial stage of it use, the employment relating to production of the system and to final destination should be considered, since these also present impacts. In the case of PEMFC, their previous and subsequent phases of use are issues related to the platinum catalysts, which indicates an environmental importance that cannot be overlooked. In this sense, the Life Cycle Assessment has been used to understand and to question the risks and opportunities that are associated to certain product, starting from a systemic concept of their relationships with the environment. It is precisely in this context that the present research intends to present its major contribution, starting from an exploratory study towards the its objectives to provide an environmental analysis of such technology linked to post stage of powder-use of the membrane electrode assembly - MEA, concerning the platinum catalysts, on the subject of Life Cycle Assessment - LCA. To attain such aim, the relationships between energy, environment and development are presented and discussed, as well as, the Fuel Cell technology and the current studies on LCA of PEMFC. Several questions raised up on this issues have contributed in the development of a method of recuperating the PEMFC catalysts and, particularly, for its subsequent environmental evaluation. Among significant results are the importance of LCA, out lined as useful tool for perceiving the weight of environmental matters concerning the platinum and its subsidy strategies relating to the development, consolidation and to the innovation of PEMFC. (author)

  6. Inorganic composition determination and evaluation of the biological activity of Peperomia pellucida in the Aspergillus flavus growth; Estudo da composicao inorganica e avaliacao da atividade biologica de Peperomia pellucida no crescimento de Aspergillus flavus

    Energy Technology Data Exchange (ETDEWEB)

    Sussa, Fabio Vitorio

    2011-07-01

    In recent decades, there has been a great advancement in research in developing drugs from plants. Nevertheless, little significant care exists in the literature about the stable concentration of elements, as well as the activity concentration of '2{sup 38}U and {sup 232}Th decay products in plants used for this purpose in Brazil. The presence of stable elements and radionuclides in plants constitutes the pathway for their migration to humans, via uptake of tea or remedies made with medicinal herbs. Peperomia pellucida, whose popular name is 'erva de jabuti', is a plant known by its medicinal usages, such as healing and analgesic properties plus antibacterial and antifungal activities against food fungi. In this study, the elemental composition of Peperomia pellucida and surrounding soil samples collected in the Botanical Garden in Rio de Janeiro was determined; the elemental concentration in the alcoholic extract and infusion processes of dry plants was also determined. The elemental concentration of As, Ba, Br, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Nd, Rb, Sb, Sc, Sm, Ta, Tb, Th, U, Yb and Zn was determined in the leaves, aerial parts, including leaves, stems and roots of Peperomia pellucida, in their extracts obtained by maceration and infusions and in the surrounding soil by the Instrumental Neutron Activation Analysis (INAA). The analytical methodology used to determine the elements Cd, Hg and Pb was the Atomic Absorption Spectrometry (AAS); the activities of {sup 226}Ra, {sup 228}Ra and {sup 210}Pb were carried out by gross alpha and beta counting, after radiochemical separation. The quality of the obtained results was assured by the analyses of the certified reference materials IAEA-336 Lichen, IAEA-Soil-7, IAEA-326 Radionuclides in soil, NIST 1515 Apple Leaves and NIST 1542 Peach Leaves. The relative standard deviations and the relative errors obtained in these analyses indicated good precision and accuracy of the results. The essential oil, ethanolic and hexane extracts of Peperomia pellucida were tested for antifungal activity against Aspergillus flavus in vitro on Petri plates. The antifungal activity was based on the inhibition zone and IC{sub 50} values against the pathogen on Petri plates assays. Also, the essential oil chemical composition was determined by GC-MS. (author)

  7. Assessment of atmospheric pollution of chemical elements by epiphytic lichen analysis at the Campus of the Sao Paulo University; Avaliacao da poluicao atmosferica de elementos quimicos pela analise de liquen epifitico no Campus da Cidade Universitaria de Sao Paulo

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Rosiana Rocho

    2015-07-01

    Air pollution has been a frequent topic of research, due to the effects that it can cause on the health of living organisms, environment and climate. In order to identify pollution sources and their effects, biomonitoring has been studied due to its low cost and possibility of sampling in wide geographic areas. In this study for passive biomonitoring of air pollution levels at the Cidade Universitaria Armando Salles de Oliveira (CUASO), University of Sao Paulo campus, epiphytic lichens of Canoparmelia texana species were used. The lichens collected from tree barks at different sampling sites in the CUASO were cleaned, freeze-dried and ground for analyses. Lichen samples were analyzed by X - ray fluorescence spectrometry (XRFS) and neutron activation analysis (NAA). For XRFS, cylindrical pellets of samples were prepared to determine As, Br, Ca, Cl, Cr, Cu, Fe, K, Mn, Rb, S, Sr and Zn. For NAA, lichen sample aliquots along with synthetic elemental standards were irradiated both for short and long periods at the IEA-R1 nuclear research reactor. The induced activities were measured by a gamma ray spectrometer to determine As, Br, Ca Cd, Cl, Co, Cr, Cs, Cu, Fe, K, La, Mg, Mn, Rb, Sb, Sc, Se, U, V and Zn. The precision and accuracy of the results were evaluated by the analysis of certified reference materials (MRCs). Their results of relative errors and standard deviations were below 15% for most of the elements. The standardized difference or En score values were lower than |1| indicating satisfactory results. Replicate analyses of a lichen sample by XRFS and NAA, indicated good homogeneity of the sample for the elements determined. The lichen results showed that the mean concentrations of As, Br, Ca, Cd, Co, Cr, Cs, Rb, Sb, Se and U were higher in samples from CUASO than those from regions considered unpolluted. For Fe, K, La, S, V and Zn, they were of the same order of magnitude. The correlation study between the elements showed high correlation (r > 0.7) for elements originated from the natural and anthropogenic sources. The principal component analysis (PCA) applied to the results showed six major components, where components 1 and 2 accounted for 52.9 % of the variance of the data. Enrichment factors (EF) calculated for the results of lichens from CUASO and a region considered unpolluted were EF> 1 for most elements, showing that these elements may be from anthropogenic sources. From the results obtained in this study can be concluded that the elements found in lichens from CUASO can be originated from sources such as resuspension of soil particles and anthropogenic emissions. (author)

  8. Evaluation of image quality versus doses in service of mammography of Belo Horizonte, MG, BR; Avaliacao da qualidade da imagem versus doses em servicos de mamografia de Belo Horizonte

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, M.; Nogueira, M.S.; Guedes, E. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Seguranca Nuclear; Andrade, M.C. [Superintendencia Estadual de Vigilancia Sanitaria, Belo Horizonte, MG (Brazil); Peixoto, J.E. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Radiologia; Silva, V.L.S.; Borges, J.C. [Vigilancia Sanitaria da Secretaria Municipal de Saude de Belo horizonte (VISA/PBH), MG (Brazil)

    2004-07-01

    Cancer is the second cause of death for Brazilian women and breast cancer is the most common neoplasm amongst women. Mammography is an essential tool for diagnosis and early detection of this disease. In order to be effective, the mammography must be of good quality. This study sought to evaluate the radiation protection and quality of 37 services out a total of 82 mammography facilities existing in the city of Belo Horizonte, Brazil. Two instruments were used: a proposed evaluation protocol of the Health Surveillance -VISA and a protocol for evaluation of image quality. Of the 37 services who completed the study, none was achieved 100% conformity in image quality. The results of radiation protection requirements according to the VISA protocol bore close relation to final image quality, a central issue for early cancer detection (p>0.05)

  9. Evaluation of {sup 137}Cs mobility in soil profiles from the Pantanal region, Brazil; Avaliacao da mobilidade do {sup 137}Cs em perfis de solos da regiao do Pantanal

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Fernanda Leite da

    2013-07-01

    Radioactive pollutants can cause impact on the environmental quality of soils and pose a risk to human health. The release of radioactive materials through nuclear testing or nuclear accidents cause the deposition of radionuclides on the ground,· it may be leached by rain, transported to the sources of natural waters and absorbed by the soil fauna and flora, and thus enter the human food chain. Radioecological studies have shown that soils with low pH, low organic matter content and low fertility are more vulnerable to contamination by {sup 137}Cs, since the transfer to plants is high. In this study, we aimed to assess and map the vulnerability to contamination by {sup 137}Cs surface horizons of the soils from the Pantanal and propose mitigation measures adapted to the regional scenario to optimize radiological protection of agricultural areas. Therefore, selected soil profiles located in the municipality of Jaraguari, state of Mato Grosso do Sul, and applied the conceptual model developed by Picanco Jr (2012), which was used in the reference values of the factor of soil-plant transfer (FT) for {sup 137}Cs in corn, related soil variables (pH, CTC and exchangeable K) and relevance of parameters and variations of amplitudes for each value range of FT. The application of this conceptual model established to detect the vulnerability of soils to radioactive contamination generated maps vulnerability showing that the region is very heterogeneous as this criterion, showing low levels of vulnerability for most of the region and in some areas, extreme vulnerability. This result identified the Pantanal as one of the less vulnerable to the radioactive contamination, but the sparse areas of extreme vulnerability can lead to contamination of subsoil and a significant spread of contamination via groundwater. This conceptual model, which defines vulnerability classification, is a first step for the study and determination of a numerical index of vulnerability to {sup 137}Cs soil and can be used in the task of remediation in case of rural areas by accident and {sup 137}Cs contamination establishing geographic areas where we should prioritize treatment due to a greater vulnerability. (author)

  10. Evaluation gamma radiation in composite sisal fiber- polyurethane derived of castor oil by bending test; Avaliacao da influencia da radiacao gama em compositos de fibra de sisal - poliuretano derivado de oleo de mamona atraves de ensaios de flexao

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Felipe H. de; Geraldo, Ricardo R.; Vasco, Marina C.; Azevedo, Elaine, E-mail: helunica@yahoo.com.br [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Claro Neto, Salvador [Universidade de Sao Paulo (USP), Sao Carlos, SP (Brazil). Instituto de Quimica

    2015-07-01

    Materials used for making furniture and accessories or positioning in X -ray examination rooms should not exhale volatile organic compounds and are resistant to ionizing radiation. One solution is the use of vegetable fiber and polyurethane composites of vegetable origin, since they are biodegradable, derived from renewable raw materials and have no volatile organic compounds. The main difficulty in developing this material is fiber adhesion with the polymer. The objective of this study is to evaluate the mechanical properties of composite sisal fiber composite, without further treatment, and polyurethane derived from castor oil, with a dose of 25 kGy gamma radiation, subjected to 3 points bending tests. (author)

  11. Evaluation exposure to the ionizing radiation of workers during the operation of first Brazilian uranium mine; Avaliacao da exposicao de trabalhadores a radiacao ionizante durante a operacao da primeira mina de uranio do Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Wagner de S.; Oliveira, Sergio Q. de; Py Junior, Delcy de A.; Dantas, Marcelino V.A.; Silva, Ana Claudia A.; Garcia Filho, Oswaldo, E-mail: wspereira@inb.gov.b, E-mail: sergioquinet@inb.gov.b, E-mail: delcy@inb.gov.b, E-mail: marcelino@inb.gov.b, E-mail: anasilva@inb.gov.b, E-mail: ogarcia@inb.gov.b [Industrias Nucleares do Brasil (UTM/INB), Pocos de Caldas, MG (Brazil). Unidade de Tratamento de Minerios. Servico de Radioprotecao

    2011-10-26

    The production of uranium in Brazil initiated, in industrial scale, in the year of 1982, in the Miner-Industrial Complex at Pocos de Caldas, Minas Gerais, Brazil. This paper analysed the data of 13410 individual historic of dose, registered along the years of work, bay the radioprotection service of installation. Descriptive statistics and frequency histograms based on dose historic, and the annual distribution doses and the accumulated doses were evaluated during the functioning period of the CIPC, and his adequacy to the in force legislation at the time of it operation

  12. Profit of solar energy for salting and drying of a brazilian fish Colossoma mitrei Berg, 1895; Utilizacao da energia solar para avaliacao da salga e secagem do pacu, Colossoma mitrei Berg, 1895

    Energy Technology Data Exchange (ETDEWEB)

    Sales, Ronaldo de Oliveira [1Ceara Univ., Fortaleza, CE (Brazil). Centro de Ciencias Agrarias; Beirao, Luiz Henrique [Santa Catarina Univ., Florianopolis, SC (Brazil). Dept. de Ciencias e Tecnologia de Alimentos

    1986-12-01

    This paper studied a simple method for processing dried-salted `pacu` fish. The average weight in relation to total weight was 58,6% and the result came very close to the average of weight of other dried salted fishes, when treated in same way. The main purpose of this process was to reduce the long time expanded by the conventional process, allowing to reduce the humidity of the dried-salted product from 56 to 43,5% in 28 hours only. (author) 20 refs., 3 figs., 8 tabs.

  13. Evaluation of the influence of water and oil derivatives absorption on PVC pipes; Avaliacao da influencia da absorcao de agua e de derivados de petroleo em tubulacoes de PVC

    Energy Technology Data Exchange (ETDEWEB)

    Carpio, D.C.F. del; D' Almeida, J.R.M., E-mail: dalmeida@puc-rio.b [Pontificia Univ. Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. de Engenharia de Materiais

    2010-07-01

    PVC is the only polymer of large consume that is not totally obtained from petroleum, since it contains 57% of chlorine. As chlorine containing materials are resistant to bacteria rich environments, such as buried pipes, PVC is being used for fluid transportation, principally water, but it can also be considered as an alternative material for the transportation of other fluids. This work analyzes the aging behavior of PVC exposed to water, ethanol and diesel oil, using TGA, DSC, FT-IR and DR-X techniques. The results showed that the chemical structure of PVC is not affected by exposure to water and ethanol. For these fluids a dipolar interaction could be occurring, increasing at the beginning of the absorption process, the polymer thermal stability. The diesel oil caused plasticization, with reduction of the Tg since the beginning of the aging process. (author)

  14. Assessment of {sup 222}Rn occupational exposure at IPEN nuclear materials storage site, SP, Brazil; Avaliacao da exposicao ocupacional ao {sup 222}Rn no galpao da Salvaguardas do IPEN, SP

    Energy Technology Data Exchange (ETDEWEB)

    Caccuri, Lilian Saueia

    2007-07-01

    In this study it was assessed the occupational exposure to {sup 222}Rn at IPEN, SP, Brazil, nuclear materials storage site through the committed effective dose received by workers exposed to this radionuclide. The radiation dose was calculated through the radon concentrations at nuclear materials storage site. Radon concentrations were determined by passive detection method with solid state nuclear detectors (SSNTD). The SSNTD used in this study was the polycarbonate Makrofol E; each detector is a small square plastic of 1 cm{sup 2}, placed into a diffusion chamber type KFK. It was monitored 14 points at nuclear materials storage site and one external point, over a period of 21 months, changing the detectors every three months, from December 2004 to September 2006. The {sup 222}Rn concentrations varied from 196 {+-} 9 and 2048 {+-} 81 Bq{center_dot}m{sup -3}. The committed effective dose due to radon inhalation at IPEN nuclear materials storage site was obtained from radon activity incorporated and dose conversion factor, according to International Commission on Radiological Protection procedures. The effective committed dose received by workers is below 20 mSv{center_dot}y{sup -1}. This value is suggested as an annual effective dose limit for occupational exposure by ICRP 60. (author)

  15. Strategic environmental assessment applied to the oil and gas planning in Brazil: a proposal; O uso da avaliacao ambiental estrategica no planejamento da oferta de blocos para exploracao e producao de petroleo e gas natural no Brasil: uma proposta

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Izabella Monica Vieira

    2008-01-15

    This thesis discusses the opportunity to apply strategic environmental assessment (SEA) to the oil and gas planning procedures in Brazil, considering the call for bids' process that has been adopted by the Federal Government since 1999. The thesis presents a literature review on the concepts and principles of environmental assessment, environmental impact assessment and strategic environmental assessment, considering its origins and practice. It also provides an appraisal of the international practice on SEA application to the oil and gas sector planning, as well as and a comparative analysis of the planning system as practiced in Brazil. Based on the international and the national SEA experience, and considering the requirements to address the environmental feasibility of oil and gas offshore activities, a proposal is presented on the framework for the use of the SEA as part of the oil and gas planning process in Brazil, together with the procedural requirements to be met. (author)

  16. Study of the heterogeneity effects of lung in the evaluation of absorbed dose in radiotherapy; Estudo dos efeitos da heterogeneidade de pulmao na avaliacao da dose absorvida em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Luciana Tourinho

    2006-02-15

    The main objective of radiotherapy is to deliver the highest possible dose to the tumour, in order to destroy it, reducing as much as possible the doses to healthy tissues adjacent to the target volume. Therefore, it is necessary to do a planning of the treatment. The more complex is the treatment, the more difficult the planning will be, demanding computation sophisticated methods in its execution, in order to consider the heterogeneities present in the human body. Additionally, with the appearing of new radiotherapeutic techniques, that used irradiation fields of small area, for instance, the intensity modulated radiotherapy, the difficulties for the execution of a reliable treatment planning, became still larger. In this work it was studied the influence of the lung heterogeneity in the planning of the curves of percentage depth dose, PDP, obtained with the Eclipse{sup R} planning system for different sizes of irradiation fields, using the correction algorithms for heterogeneities available in the planning system: modified Batho, general Batho and equivalent tissue-air ratio. A thorax phantom, manufactured in acrylic, containing a region made of cork to simulate the lung tissue, was used. The PDP curves generated by the planning system were compared to those obtained by Monte Carlo simulation and with the use of thermoluminescent, TL, dosimetry. It was verified that the algorithms used by the Eclipse{sup R} system for the correction of heterogeneity effects are not able to generate correct results for PDP curves in the case of small fields, occurring differences of up to 100%, when the 1x1 cm{sup 2} treatment field is considered. These differences can cause a considerable subdosage in the lung tissue, reducing the possibility of the patient cure. (author)

  17. Mining adaptation to the radioprotection regulations: evaluation of the regulation CNEN-NN-4.01; Adaptacao da mineracao as normas de radioprotecao: avaliacao da Norma CNEN-NN-4.01

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Wagner de Souza; Kelecom, Alphonse [Universidade Federal Fluminense (LARARA/UFF), Niteroi, RJ (Brazil). Lab. de Radiobiologia e Radiometria; Silva, Cleber Jabarra da; Campinhos, Gabriela Michalsky [Jabarra Servicos e Comercio de Radioprotecao Ltda., Rio de Janeiro, RJ (Brazil). Consultoria em Radioprotecao

    2011-10-26

    This paper proposes a generic model of monitoring to be used in mining with uranium or thorium associated viewing to estimate the dose of workers for classification the mining in the specific question of worker exposure. Besides the monitoring model, a dosimetric model also is proposed. It is indicated some instruments and techniques used in individual and area monitoring, besides to point out the necessity of radioprotection supervisor specific in this area

  18. Evaluation of eco toxicity, biocide effectiveness and corrosiveness of fluid for pipelines hydro testing; Avaliacao da ecotoxicidade, eficiencia biocida e da corrosividade de fluidos para teste hidroestatico de dutos

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Cynthia A.; Veiga, Leticia F.; Penna, Monica O.; Souza, Leonardo S. [PETROBRAS, Rio de Janeiro, RJ (Brazil); Nascimento, Juliana R.; Oliveira, Fabio F.; Amigo, Alexandre A.; Chaves, Claudia [Fundacao Gorceix, Ouro Preto, MG (Brazil)

    2005-07-01

    Before the installation of subsea pipelines for draining the oil and gas production, the line need to be submitted to hydrostatic tests. In these, the lines are flooded with sea water and chemicals and pressurized to check the leakage occurrence. By the end of the test, the fluid needs to be discharged in-situ. Based on the environmental restrictions, this study began, and the three most important aspects in relation to the environmental risks had been evaluated: the toxicity, the biocide efficiency and the fluids' corrosiveness. By the partial results, it was observed that the fluids which had presented the best results in all studied aspects were the ones that contained the biocide THPS, combined with U.V. and a quaternary salt. In relation to the corrosion, it could be established that the studied fluids do not present impacts in internal corrosion, since during the test, the pipes are totally flooded with the fluid, remaining stamped and all the internal air having been removed. An important aspect is: even with concentrations below of the recommended ones for biocides, in order to guarantee lower environmental risks, by making use of alternative techniques (U.V.) and efficient biocide products, it is also possible to reach success in terms of biocide's efficiency. A regular monitoring procedure of the fulfilling fluid's quality is essential. (author)

  19. Combined discrete nebulization and microextraction process for molybdenum determination by flame atomic absorption spectrometry (FAAS); Avaliacao da combinacao da nebulizacao discreta e processos de microextracao aplicados a determinacao de molibdenio por espectrometria de absorcao atomica com chama (FAAS)

    Energy Technology Data Exchange (ETDEWEB)

    Oviedo, Jenny A.; Jesus, Amanda M.D. de; Fialho, Lucimar L.; Pereira-Filho, Edenir R., E-mail: erpf@ufscar.br [Universidade Federal de Sao Carlos (UFSCar), SP (Brazil). Departamento de Quimica

    2014-04-15

    Simple and sensitive procedures for the extraction/preconcentration of molybdenum based on vortex-assisted solidified floating organic drop microextraction (VA-SFODME) and cloud point combined with flame absorption atomic spectrometry (FAAS) and discrete nebulization were developed. The influence of the discrete nebulization on the sensitivity of the molybdenum preconcentration processes was studied. An injection volume of 200 μ resulted in a lower relative standard deviation with both preconcentration procedures. Enrichment factors of 31 and 67 and limits of detection of 25 and 5 μ L{sup -1} were obtained for cloud point and VA-SFODME, respectively. The developed procedures were applied to the determination of Mo in mineral water and multivitamin samples. (author)

  20. Evaluation of natural rubber from IAC series clones by solid state {sup 13}C NMR; Avaliacao da borracha natural de clones da serie IAC por {sup 13}C RMN no estado solido

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Maria A.; Moreno, Rogerio M.B.; Goncalves, Paulo S. [Instituto Agronomico de Campinas, SP (Brazil). Centro de Cafe e Plantas Tropicais. Programa Seringueira]. E-mails: paulog@iac.sp.gov.br; mariaalice@cnpdia.embrapa.br; Forato, Lucimara A.; Colnago, Luiz A.; Mattoso, Luiz H.C. [EMBRAPA Instrumentacao Agropecuaria, Sao Carlos, SP (Brazil)]. E-mail: colnago@cnpdia.embrapa.br; forato@cnpdia.embrapa.br; rogerio@cnpdia.embrapa.br; mattoso@cnpdia.embrapa.br; Job, Aldo E. [Universidade Estadual Paulista (UNESP), Presidente Prudente, SP (Brazil). Departamento de Fisica, Quimica e Biologia

    2005-07-01

    Agronomic Institute (IAC) and EMBRAPA Agricultural Instrumentation (EMBRAPA/CNPDIA) have been studied Hevea species in order to increase the production of the natural rubber and to develop new clones more appropriated to Brazil's soil and climate. Structural characterization of natural rubber [Hevea brasiliensis (Willd. ex Adr. de Juss.) Muell. - Arg.] from new clones of the IAC series (IAC 300, 301, 302, 303, 35, 40, and 56) and from RRIM 600 clone has been studied by high-resolution solid-state {sup 13}C NMR and by single pulse technique. The results have shown that the application of solid-state {sup 13}C NMR using the single pulse technique is a powerful tool to study natural rubber. The spectra obtained through this technique confirmed that natural rubber from all clones studied are cis-1,4-polyisoprene (author) form.(author)

  1. Dosimetric evaluation of spectrophotometric response of alanine gel solution for gamma, photons, electrons and thermal neutrons radiations; Avaliacao dosimetrica da resposta espectrofotometrica da solucao gel de alanina para radiacao gama, de fotons, de eletrons e de neutrons termicos

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Cleber Feijo

    2009-07-01

    Alanine Gel Dosimeter is a new gel material developed at IPEN that presents significant improvement on Alanine system developed by Costa. The DL-Alanine (C{sub 3}H{sub 7}NO{sub 2}) is an amino acid tissue equivalent that improves the production of ferric ions in the solution. This work aims to analyse the main dosimetric characteristics this new gel material for future application to measure dose distribution. The performance of Alanine gel solution was evaluated to gamma, photons, electrons and thermal neutrons radiations using the spectrophotometry technique. According to the obtained results for the different studied radiation types, the reproducibility intra-batches and inter-batches is better than 4% and 5%, respectively. The dose response presents a linear behavior in the studied dose range. The response dependence as a function of dose rate and incident energy is better 2% and 3%, respectively. The lower detectable dose is 0.1 Gy. The obtained results indicate that the Alanine gel dosimeter presents good performance and can be useful as an alternative dosimeter in the radiotherapy area, using MRI technique for tridimensional dose distribution evaluation. (author)

  2. Dosimetric evaluation of a combination of brachytherapy applicators for uterine cervix cancer with involvement of the distal vagina; Avaliacao dosimetrica de uma combinacao de aplicadores para braquiterapia de tumores do colo uterino com acometimento da porcao distal da vagina

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Roger Guilherme Rodrigues [Real e Benemerita Sociedade Portuguesa de Beneficencia, Sao Paulo, SP (Brazil). Servico de Radioterapia Estereotactica; Carvalho, Heloisa de Andrade; Stuart, Silvia Radwanski; Rubo, Rodrigo Augusto [Universidade de Sao Paulo (USP), SP (Brazil). Hospital das Clinicas. Servico de Radioterapia], e-mail: handrade@hcnet.usp.br; Seraide, Rodrigo Migotto [Centro de Oncologia Campinas, SP (Brazil)

    2009-07-15

    Objective: To evaluate an alternative brachytherapy technique for uterine cervix cancer involving the distal vagina, without increasing the risk of toxicity. Materials And Methods: Theoretical study comparing three different high-dose rate intracavitary brachytherapy applicators: intrauterine tandem and vaginal cylinder (TC); tandem/ring applicator combined with vaginal cylinder (TR+C); and a virtual applicator combining both the tandem/ring and vaginal cylinder in a single device (TRC). Prescribed doses were 7 Gy at point A, and 5 Gy on the surface or at a 5 mm depth of the vaginal mucosa. Doses delivered to the rectum, bladder and sigmoid colon were kept below the tolerance limits. Volumes covered by the isodoses, respectively, 50% (V50), 100% (V100), 150% (V150) and 200% (V200) were compared. Results: Both the combined TR+C and TRC presented a better dose distribution as compared with the TC applicator. The TR+C dose distribution was similar to the TRC dose, with V150 and V200 being about 50% higher for TR+C (within the cylinder). Conclusion: Combined TR+C in a two-time single application may represent an alternative therapy technique for patients affected by uterine cervix cancer involving the distal vagina. (author)

  3. Strategic environmental assessment applied to the oil and gas planning in Brazil: a proposal; O uso da avaliacao ambiental estrategica no planejamento da oferta de blocos para exploracao e producao de petroleo e gas natural no Brasil: uma proposta

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Izabella Monica Vieira

    2008-01-15

    This thesis discusses the opportunity to apply strategic environmental assessment (SEA) to the oil and gas planning procedures in Brazil, considering the call for bids' process that has been adopted by the Federal Government since 1999. The thesis presents a literature review on the concepts and principles of environmental assessment, environmental impact assessment and strategic environmental assessment, considering its origins and practice. It also provides an appraisal of the international practice on SEA application to the oil and gas sector planning, as well as and a comparative analysis of the planning system as practiced in Brazil. Based on the international and the national SEA experience, and considering the requirements to address the environmental feasibility of oil and gas offshore activities, a proposal is presented on the framework for the use of the SEA as part of the oil and gas planning process in Brazil, together with the procedural requirements to be met. (author)

  4. Preliminary evaluation of the utilization of biopiles technology to the bioremediation of the soil of Guamare/RN (Brazil); Avaliacao preliminar da aplicacao da tecnologia de biopilhas para a biorremediacao do solo de Guamare/RN (Brasil)

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Edmilson P.; Macedo, Gorete R.; Duarte, Marcia M.L. [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Dept. de Engenharia Quimica; Costa, Alex S.S. [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil)

    2004-07-01

    The aim of this work was to evaluate the use of biopiles to the bioremediation of the soil of Stabilization Station of Guamare-RN-Brazil. The evaluation was performed by the characterization of the soil, tests of biodegradation in laboratory scale and by the use of a complete 2{sup 3} factorial design with triplicate at the central point. The input variables were: Nitrogen concentration; diesel-oil concentration; and inoculum concentration. The response variable was the percentage gravimetric loss of organic matter. Statistical analyses of the main factors and their interactions on the response variable were performed using contour curves and Pareto obtained from the software STATISTICA for Windows, Release 5.5. The results showed that biopiles technology can be used to remediate eventual contaminated areas in that region. (author)

  5. Evaluation of the dose absorbed by the thyroid of patients undergoing treatment of Graves disease;Avaliacao da dose absorvida pela tireoide de pacientes submetidos ao tratamento da doenca de Graves

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Tiago L.; Filho, Joao A. [Universidade Catolica de Pernambuco (UNICAP), Recife, PE (Brazil). Dept. de Fisica; Silva, Jose M.F. da [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

    2009-07-01

    The radioiodine is used as complementary treatment of thyroid cancer and as first choice for the treatment of Graves' disease, being efficient, safe and easy administration, but without there is a protocol defined. This work was evaluated the thyroid absorbed dose from its mass and maximum uptake of I-131 obtained in the examination of diagnostic radiology of radiotherapeutic patients undergoing treatment of Graves' disease. Based on the results, it is observed that the thyroid absorbed dose, as much in terms of mass as the maximum uptake of I-131 for different values of administered activity, varies significantly. The analysis of these parameters is an excellent indicator for the pre-define quantity of radionuclide that is administered to the patient in terms of the radiation dose required to achieve an efficient therapeutic treatment. Moreover, it was observed that the thyroid absorbed dose depends on the degree of pathology of the disease, its mass and of the maximum uptake of I-131. (author)

  6. Evaluation of radiological protection and dose of skin entrance in paediatric dentistry examinations; Avaliacao da protecao radiologica e da dose de entrada na pele em exames de odontologia pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Khoury, Helen Jamil [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Vasconcelos, Flavia Maria Nassar de [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Silveira, Marcia Maria Fonseca da [Universidade de Pernambuco (UPE), Recife, PE (Brazil). Fac. de Odontologia; Couto, Geraldo Bosco Lindoso [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Fac. de Odontopediatria; Brasileiro, Izabela Vanderley

    2005-07-01

    In this work the radiological protection conditions and dose at the entrance of pediatric patients undergoing dental intraoral radiographs were evaluated. The study was conducted in two clinics of the dentistry course at the Federal University of Pernambuco, Recife, PB, Brazil, equipped with conventional X-ray apparatus, with 60 and 70 kV. 254 exams of 113 patients between the ages of 3 to 12 years were evaluated. The skin entrance dose was estimated using TLD-100 thermoluminescent dosemeters. During the examination were also recorded information regarding the time of exposure, radiographic technique used, use of thyroid protectors and lead apron, angle and distance of the cone Locator to the patient's skin. The results showed that the input skin doses ranged from 0.3 mGy to 10mGy. The lead apron was used in 71% of exams while the thyroid shield was only used in 58% of the exams. The exposure times ranged from 0,5s to 1,5s. From the results it can be concluded that the radiological procedures are not optimized and that in some cases the patient dose is high.

  7. Aplicações da tomografia de ressonância magnética nuclear como método não-destrutivo para avaliar os efeitos de injúrias mecânicas em goiabas 'Paluma' e 'Pedro Sato' Applications of the nuclear magnetic resonance tomography as a non-destructive method to evaluate the effects of mechanical injuries in 'Paluma' and 'Pedro Sato' guavas

    Directory of Open Access Journals (Sweden)

    Ben-Hur Mattiuz

    2002-12-01

    Full Text Available Objetivou-se determinar o potencial do uso da tomografia de ressonância magnética, como método não-destrutivo, para avaliar os efeitos das injúrias mecânicas em goiabas. Foram utilizados frutos no estádio de maturação "de vez" das cultivares Paluma e Pedro Sato. Na injúria por impacto, os frutos foram deixados cair, em queda livre, de uma altura de 1,20 m, sofrendo dois impactos, em lados opostos de sua porção equatorial. Na injúria por compressão, os frutos foram submetidos a um peso de 29,4 N, por 15 minutos. Para a injúria por corte, foram efetuados dois cortes, no sentido longitudinal dos frutos, de exatamente 30 mm de comprimento por 2 mm de profundidade. Os frutos injuriados foram armazenados sob condições de ambiente (22 ± 2 °C e 40 %UR. Foram realizadas análises com tomógrafo de ressonância magnética Varian Inova de 2 Tesla. As imagens foram obtidas a partir da detecção dos prótons de hidrogênio (¹H. Para cada fruto, foram obtidos tomogramas simétricos a partir do centro do fruto. A tomografia de ressonância magnética nuclear mostrou-se uma ferramenta eficaz na detecção de injúrias internas de frutos. O estresse físico causado pelo impacto produziu um colapso interno nos lóculos desses frutos (internal bruising, levando à perda da integridade celular e a conseqüente liquefação dos tecidos placentários. A cultivar Pedro Sato mostrou uma suscetibilidade maior à injúria por impacto que a 'Paluma'. A injúria por compressão tornou-se mais evidente no pericarpo externo do fruto, de ambas as cultivares. A injúria por corte levou a lignificação dos tecidos no local injuriado e deformações superficiais devido à perda acentuada de matéria fresca no local da lesão, evidentes no sexto dia de avaliação.The present study reports on the potential of the use of the tomography of magnetic resonance, as a non-destructive method, to evaluate the effects of the mechanical injuries in guava fruits

  8. Positron emission tomography molecular imaging of dopaminergic system in drug addiction.

    Science.gov (United States)

    Hou, Haifeng; Tian, Mei; Zhang, Hong

    2012-05-01

    Dopamine (DA) is involved in drug reinforcement, but its role in drug addiction remains unclear. Positron emission tomography (PET) is the first technology used for the direct measurement of components of the dopaminergic system in the living human brain. In this article, we reviewed the major findings of PET imaging studies on the involvement of DA in drug addiction, especially in heroin addiction. Furthermore, we summarized PET radiotracers that have been used to study the role of DA in drug addiction. To investigate presynaptic function in drug addiction, PET tracers have been developed to measure DA synthesis and transport. For the investigation of postsynaptic function, several radioligands targeting dopamine one (D1) receptor and dopamine two (D2) receptor are extensively used in PET imaging studies. Moreover, we also summarized the PET imaging findings of heroin addiction studies, including heroin-induced DA increases and the reinforcement, role of DA in the long-term effects of heroin abuse, DA and vulnerability to heroin abuse and the treatment implications. PET imaging studies have corroborated the role of DA in drug addiction and increase our understanding the mechanism of drug addiction. Copyright © 2012 Wiley Periodicals, Inc.

  9. Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Pier Alberto Testoni

    2007-01-01

    Full Text Available Optical coherence tomography (OCT is an optical imaging modality that performs high-resolution, cross-sectional, subsurface tomographic imaging of the microstructure of tissues. The physical principle of OCT is similar to that of B-mode ultrasound imaging, except that it uses infrared light waves rather than acoustic waves. The in vivo resolution is 10–25 times better (about 10 µm than with high-frequency ultrasound imaging, but the depth of penetration is limited to 1–3 mm, depending on tissue structure, depth of focus of the probe used, and pressure applied to the tissue surface. In the last decade, OCT technology has evolved from an experimental laboratory tool to a new diagnostic imaging modality with a wide spectrum of clinical applications in medical practice, including the gastrointestinal tract and pancreatico-biliary ductal system. OCT imaging from the gastrointestinal tract can be done in humans by using narrow-diameter, catheter-based probes that can be inserted through the accessory channel of either a conventional front-view endoscope, for investigating the epithelial structure of the gastrointestinal tract, or a side-view endoscope, inside a standard transparent ERCP (endoscopic retrograde cholangiopancreatography catheter, for investigating the pancreatico-biliary ductal system. The esophagus and esophagogastric junction have been the most widely investigated organs so far; more recently, duodenum, colon, and the pancreatico-biliary ductal system have also been extensively investigated. OCT imaging of the gastrointestinal wall structure is characterized by a multiple-layer architecture that permits an accurate evaluation of the mucosa, lamina propria, muscularis mucosae, and part of the submucosa. The technique may therefore be used to identify preneoplastic conditions of the gastrointestinal tract, such as Barrett's epithelium and dysplasia, and evaluate the depth of penetration of early-stage neoplastic lesions. OCT imaging

  10. Tópicos da teoria da relatividade

    OpenAIRE

    Fragata, Paulo Renato Ferreira

    2013-01-01

    Dissertação de Mestrado, Matemática para Professores, 25 de Outubro 2013, Universidade dos Açores. Qualquer descrição física da natureza tem por base a especificação da posição e do instante em que decorre determinado acontecimento. Para tal, é necessário recorrer a um sistema de coordenadas, escolhido por cada observador, do modo que ele achar mais pertinente. Dada a generalidade na escolha do sistema de coordenadas, é útil conhecer as regras que nos permitem comparar cálculos feitos em d...

  11. Digital hilar tomography. Comparison with conventional technique

    International Nuclear Information System (INIS)

    Schaefer, C.B.; Braunschweig, R.; Teufl, F.; Kaiser, W.; Claussen, C.D.

    1993-01-01

    The aim of the following study was to compare conventional hilar tomography and digital hilar tomography. 20 patients were examined both with conventional and digital hilar tomography using the same tomographic technique and the identical exposure dose. All patients underwent computed tomography of the chest as a golden standard. The digital technique, especially the edge-enhanced image version, showed superior image quality. ROC-analysis by 4 readers found equal diagnostic performance without any statistical difference. Digital hilar tomography shows a superior and constant image quality and lowers the rate of re-exposure. Therefore, digital hilar tomography is the preferable method. (orig.) [de

  12. An introduction to emission computed tomography

    International Nuclear Information System (INIS)

    Williams, E.D.

    1985-01-01

    This report includes salient features of the theory and an examination of practical considerations for someone who is using or introducing tomography, selecting equipment for it or wishing to develop a clinical application. Emphasis is on gamma camera tomography. The subject is dealt with under the following headings: emission computed and gamma camera tomography and the relationship to other medical imaging techniques, the tomographic reconstruction technique theory, rotating gamma camera tomography, attenuation correction and quantitative reconstruction, other single photon tomographic techniques, positron tomography, image display, clinical application of single photon and positron tomography, and commercial systems for SPECT. Substantial bibliography. (U.K.)

  13. Left lower lobe sleeve lobectomy for lung cancer using the Da Vinci surgical system.

    Science.gov (United States)

    Zhao, Yandong; Jiao, Wenjie; Ren, Xiaoyang; Zhang, Liangdong; Qiu, Tong; Fu, Bo; Wang, Lei

    2016-04-12

    Despite the robotic surgery is widely applied, sleeve lobectomy for lung cancer using the Da Vinci surgical system is still less performed. We described a sleeve lobectomy for adenocarcinoma located at the left lower lobe using the Da Vinci surgical system. A case of 57-year old female referred to our hospital. Computed tomography scan showed an occupation located at the left lower lobe and adenocarcinoma project from the lobe bronchus was diagnosed by bronchoscope examination. A sleeve lobectomy was performed using the Da Vinci surgical system and the postoperative recovery was uneventful. Robotic thoracic surgery is feasible to perform sleeve lobectomy inspite of inadequate experience.

  14. Combined DaT imaging and olfactory testing for differentiating parkinsonian disorders

    DEFF Research Database (Denmark)

    Borghammer, Per; Knudsen, K; Østergaard, K

    2014-01-01

    ObjectiveDopamine transporter (DaT) imaging with single photon emission computed tomography (SPECT) detects loss of striatal dopaminergic innervation with very high sensitivity. It cannot readily distinguish idiopathic Parkinson's disease (iPD) and dementia with Lewy bodies (DLB) from atypical...... predicted a dopamine-deficient diagnosis with 98% sensitivity and 98% specificity. The combined DaT/olfactory testing correctly classified 91% of patients as iPD/DLB (PPV 91%). The PPV rose to 97% or greater in anosmic patients. In contrast, only 45% of aPD patients were categorised correctly by combined Da...

  15. Tomography with energy dispersive diffraction

    Science.gov (United States)

    Stock, S. R.; Okasinski, J. S.; Woods, R.; Baldwin, J.; Madden, T.; Quaranta, O.; Rumaiz, A.; Kuczewski, T.; Mead, J.; Krings, T.; Siddons, P.; Miceli, A.; Almer, J. D.

    2017-09-01

    X-ray diffraction can be used as the signal for tomographic reconstruction and provides a cross-sectional map of the crystallographic phases and related quantities. Diffraction tomography has been developed over the last decade using monochromatic x-radiation and an area detector. This paper reports tomographic reconstruction with polychromatic radiation and an energy sensitive detector array. The energy dispersive diffraction (EDD) geometry, the instrumentation and the reconstruction process are described and related to the expected resolution. Results of EDD tomography are presented for two samples containing hydroxyapatite (hAp). The first is a 3D-printed sample with an elliptical crosssection and contains synthetic hAp. The second is a human second metacarpal bone from the Roman-era cemetery at Ancaster, UK and contains bio-hAp which may have been altered by diagenesis. Reconstructions with different diffraction peaks are compared. Prospects for future EDD tomography are also discussed.

  16. Computed tomography in renal trauma

    International Nuclear Information System (INIS)

    Brueck, W.; Eisenberger, F.; Buck, J.

    1981-01-01

    In a group of 19 patients suffering from flank trauma and gross hematuria the diagnostic value of angiography was compared with that of computed tomography. The cases that underwent both tests were found to have the some diagnosis of rupture of the kidney. Typical CT-findings in kidney rupture are demonstrated. Whereas angiography presents an exact picture of the arterial system of the kidney, including its injures computed tomography reveals the extent of organ lesons by showing extra- and intrarenal hematomas. If surgery is planned angiography is still mandatory, whereby the indication is largely determined by the clinical findings. Computed tomography as a non-invasive method is equally suitable for follow-ups. (orig.) [de

  17. Recent advances in neutron tomography

    International Nuclear Information System (INIS)

    McFarland, E.; Massachusetts Inst. of Technology, Cambridge, MA; Lanza, R.

    1993-01-01

    Neutron imaging has been shown to be an excellent imaging tool for many nondestructive evaluation applications. Significantly improved contrast over X-ray images is possible for materials commonly found in engineering assemblies. The major limitations have been the neutron source and detection. A low cost, position sensitive neutron tomography detector system has been designed and built based on an electro-optical detector system using a LiF-ZnS scintillator screen and a cooled charge coupled device. This detector system can be used for neutron radiography as well as two and three-dimensional neutron tomography. Calculated performance of the system predicted near-quantum efficiency for position sensitive neutron detection. Experimental data was recently taken using this system at McClellan Air Force Base, Air Logistics Center, Sacramento, CA. With increased availability of low cost neutron sources and advanced image processing, neutron tomography will become an increasingly important nondestructive imaging method

  18. Retrospective study of computed tomography of nasal cavity in small animal at FMVZ - UNESP, Botucatu, and correlation of changes with cytological and/or histopathological exams; Estudo retrospectivo de tomografia computadorizada da cavidade nasal em pequenos animais na FMVZ - UNESP, Botucatu, e correlacao das alteracoes com os exames citologico e/ou histopatologico

    Energy Technology Data Exchange (ETDEWEB)

    Belotta, Alexandra Frey; Inamassu, Leticia Rocha; Mamprim, Maria Jaqueline; Machado, Vania Maria de Vasconcelos; Vulcano, Luiz Carlos, E-mail: a_fbelotta@yahoo.com.br [Universidade Estadual Paulista Julio de Mesquita Filho (FMVZ/UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Reproducao Animal e Radiologia Veterinaria; Zardo, Karen Maciel

    2012-07-01

    It was conducted a retrospective study of computed tomography (CT) scans of nasal cavity in small animal at this institution during the period of April 2007 through June 2012. In total, 47 CT scans were performed during the period and, of these, only 25 underwent additional exams (cytological and/or histopathological). 20 exams suggested a diagnosis, 4 were inconclusive and one had no change. A correlation was made between tomographic findings and cytological/histopathological diagnosis providing an accurate assessment of neoplastic versus non-neoplastic disease. (author)

  19. Análise das variações morfológicas da ATM em pacientes com artrite reumatóide através de tomografia computadorizada = Analysis of the morphologyc variations in the TMJ the patients with rheumatoid arthritis through the computer tomography

    Directory of Open Access Journals (Sweden)

    Vasconcelos, Belmiro Cavalcanti do Egito

    2005-01-01

    Full Text Available Realizou-se um estudo qualitativo e quantitativo enfocando as alterações morfométricas da articulação temporomandibular (ATM, em pacientes com o diagnóstico de artrite reumatóide (AR por meio de tomografia computadorizada. Foram analisados 6 casos onde são descritas as alterações estruturais dos componentes ósseos de 12 ATMs. Os resultados indicaram que todas as ATMs apresentaram alterações, sendo as alterações mais freqüentes a esclerose óssea subcondral, seguida do aplainamento da eminência articular. Todos os pacientes apresentaram distúrbio de mobilidade

  20. Positron tomography. Methodology and applications

    International Nuclear Information System (INIS)

    Kellershohn, C.; Comar, D.

    1979-01-01

    Whereas single photon tomography provides a new and rewarding dimension to conventional nuclear medicine, positron tomography makes a new original approach possible of the analysis in vivo of fundamental biological and physiological processes. The main object of both is the sectional representation of the distribution of a radioactive indicator injected into the body system; compared with conventional detectors (gamma cameras and scintigraphic systems) they provide much greater accuracy in localization. The characteristics of these two methods can be presented schematically by comparing their respective advantages and drawbacks [fr

  1. Uncertainty analysis in seismic tomography

    Science.gov (United States)

    Owoc, Bartosz; Majdański, Mariusz

    2017-04-01

    Velocity field from seismic travel time tomography depends on several factors like regularization, inversion path, model parameterization etc. The result also strongly depends on an initial velocity model and precision of travel times picking. In this research we test dependence on starting model in layered tomography and compare it with effect of picking precision. Moreover, in our analysis for manual travel times picking the uncertainty distribution is asymmetric. This effect is shifting the results toward faster velocities. For calculation we are using JIVE3D travel time tomographic code. We used data from geo-engineering and industrial scale investigations, which were collected by our team from IG PAS.

  2. Positron emission tomography in oncology

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This report describes the current and potential uses of positron emission tomography in clinical medicine and research related to oncology. Assessment will be possible of metabolism and physiology of tumors and their effects on adjacent tissues. Specific probes are likely to be developed for target sites on tumors, including monoclonal antibodies and specific growth factors that recognize tumors. To date, most oncological applications of positron emission tomography tracers have been qualitative; in the future, quantitative metabolic measurements should aid in the evaluation of tumor biology and response to treatment

  3. NMF on positron emission tomography

    DEFF Research Database (Denmark)

    Bödvarsson, Bjarni; Hansen, Lars Kai; Svarer, Claus

    2007-01-01

    In positron emission tomography, kinetic modelling of brain tracer uptake, metabolism or binding requires knowledge of the cerebral input function. Traditionally, this is achieved with arterial blood sampling in the arm or as shown in (Liptrot, M, et al., 2004) by non-invasive K-means clustering....... We propose another method to estimate time-activity curves (TAC) extracted directly from dynamic positron emission tomography (PET) scans by non-negative matrix factorization (NMF). Since the scaling of the basis curves is lost in the NMF the estimated TAC is scaled by a vector alpha which...

  4. Virtual electrical capacitance tomography sensor

    International Nuclear Information System (INIS)

    Li, Y; Yang, W Q

    2005-01-01

    Electrical capacitance tomography (ECT) is an effective technique for elucidating the distribution of dielectric materials inside closed pipes or vessels. This paper describes a virtual electrical capacitance tomography (VECT) system, which can simulate a range of sensor and hardware configurations and material distributions. A selection of popular image reconstruction algorithms has been made available and image error and capacitance error tools enable their performance to be evaluated and compared. Series of frame-by-frame results can be stored for simulating real-time dynamic flows. The system is programmed in Matlab with DOS functions. It is convenient to use and low-cost to operate, providing an effective tool for engineering experiment

  5. Cranial computed tomography in psychiatry

    International Nuclear Information System (INIS)

    Falkai, P.; Bogerts, B.

    1993-01-01

    Computed tomography has gained importance as a diagnostic tool in psychiatry to exclude structural brain pathology, but has passed on its role in research to magnetic resonance tomography. It helps to distinguish between senile dementia of Alzheimer type and multi-infarct dementia. The enlargement of the ventricular system and cortical sulci is well established in schizophrenic and affective psychosis. Some alcohol addicts show a considerable degree of cerebral atrophy, only exceeded by demented patients, but this condition is potentially reversible. To screen psychiatric patients by CT is recommendable, as 2-10% of hospitalized psychiatric patients have structural brain disease. (orig.) [de

  6. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  7. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19,2016 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  8. MACIEZ DA CARNE BOVINA

    Directory of Open Access Journals (Sweden)

    Antonio Bento Mancio

    2006-10-01

    Full Text Available Dentre as características de qualidade da carne bovina, a maciez assume posição de destaque, sendo considerada a característica organoléptica de maior influência na aceitação da carne por parte dos consumidores. A dureza da carne pode ser dividida em dureza residual, causada pelo tecido conjuntivo e outras proteínas do estroma, e dureza de actomiosina, causada pelas proteínas miofibrilares. Dentre os fatores que influenciam a maciez da carne, podem ser destacados a genética, a raça, a idade ao abate, o sexo, a alimentação, o uso de agentes hormonais (?-adrenérgicos e os tratamentos post-mortem. A qualidade final da carne é resultante de tudo o que aconteceu com o animal durante toda a cadeia produtiva. Devem-se assegurar procedimentos adequados de transporte, armazenamento, manipulação, exposição e preparo da carne, a fim de se obter um produto de melhor qualidade. PALAVRAS-CHAVE: Calpaínas, calpastatina, qualidade da carne, rigor mortis, tecido muscular.

  9. The value of computed tomography in ''sciatica''

    International Nuclear Information System (INIS)

    Boehm-Jurkovic, H.; Hammer, B.

    1981-01-01

    13 cases of therapy-resistant lumboischialgia without herniated disk, caused in 12 cases by a tumour and in 1 case by an abscess, were examined by computed tomography of the lumbar and pelvic region. This method is indicated immediately after insufficient results of conventional X-ray methods (including tomography) and of lumbosacral radiculography. The computed tomography is indispensable also in patients with ''sciatica'' with a known malignoma. The information given by computed tomography is essential for the therapy planning. (author)

  10. GERONTOLOGIA: ESTADO DA ARTE

    Directory of Open Access Journals (Sweden)

    Vera M.A.Tordino Brandão

    2010-02-01

    Full Text Available O Programa de Gerontologia da PUC desenvolve pesquisas focando o ser na perspectiva do envelhecimento. As atividades são interdisciplinares e reúnem docentes, alunos e ex-alunos. Nesta mesa redonda apresentamos um panorama sobre estes estudos. Na área da educação e comunicação o foco está centrado na longevidade e na preparação e representação social da velhice. São ressaltadas como temáticas: a formação continuada de profissionais e pesquisadores; o significado da religiosidade/espiritualidade ao longo da trajetória, e sua repercussão na qualidade de vida do idoso; os programas sócio-educacionais para idosos e concepções sobre educação; o monitoramento da mídia na cobertura da crescente longevidade e seus impactos. Em identidade e modos de morar reflete-se sobre soluções planejadas e sua adequação para a inclusão do envelhecimento populacional como questão fundamental, que implica a elaboração de novas políticas, investigações e, especialmente, apresenta-se como questão a ser analisada, refletida e vivenciada pela sociedade em geral. Quanto à saúde, o Programa desenvolve várias pesquisas numa abordagem interdisciplinar tendo como objetos de estudo: a terapia assistida com animais direcionada a idosos com diagnóstico de Alzheimer; o acompanhamento terapêutico e o atendimento psicoterapêutico em grupo, a aplicação da técnica de Calatonia em idosos moradores de ILPI, além da investigação sobre impasses clínicos no idoso frágil. Palavras-chave: gerontologia, longevidade, envelhecimento

  11. Conjecturas da Epistemológia Jurídica e Aspectos da Teoria da Linguagem

    OpenAIRE

    Oliveira, Rita de Cássia Cartelli de; Cesumar; Motta, Ivan Dias; Cesumar

    2008-01-01

    Apresentar-se-ão reflexões em torno da epistemologia jurídica e alguns aspectos da teoria da linguagem; a necessidade de acompanhamento e aprimoramento da linguagem jurídica, para que o direito não se distancie da realidade, mantendo-se apenas como um sistema do status quo; uma breve análise de algumas teorias da ciência do direito e da linguagem; as especificidades dos termos lingüísticos para a análise da ciência do direito, pautada na contemporaneidade sob a perspectiva humanista, buscando...

  12. CONDICIONANTES DA COMPETITIVIDADE EMPRESARIAL

    Directory of Open Access Journals (Sweden)

    José Luiz Contador

    2010-03-01

    Full Text Available Este trabalho examina teoricamente os fatores determinantes da competitividade do produto e do negócio, imprescindíveis à elaboração de estratégias competitivas que visam à obtenção e sustentação de vantagens competitivas. Esse tema é objeto tanto da área de marketing estratégico quanto da de estratégia empresarial. Nas duas áreas, há um ponto de consenso que afirma que a empresa deve diferenciar sua oferta para conquistar e manter vantagem competitiva. Mas, os estudos conduzidos por meio do modelo de Campos e Armas da Competição revelaram que a empresa pode diferenciar seu produto e/ou serviço de modo mais amplo, levando em consideração, na formulação da sua estratégia competitiva, também o campo da competição, quer do produto, quer dela própria. Assim, o objetivo deste artigo é evidenciar que, para a empresa ser competitiva, além de diferenciar seu produto e/ou seu serviço no sentido tradicional, ela precisa: 1 diferenciar seu produto incluindo a definição em quais campos vai competir em cada segmento; e 2 escolher as armas da competição que irá utilizar e definir a intensidade de cada arma. Para atingir tal objetivo, foram necessários vários conceitos do modelo de Campos e Armas da Competição: campo da competição, arma da competição, tese do modelo, configuração dos campos da competição, campo coadjuvante, produto coadjuvante e par produto-mercado. Como uma proposta inovadora sempre desperta dúvida, é mostrado o processo de validação do modelo de Campos e Armas da Competição e são discutidas sua universalidade, consistência e completude.

  13. Protean appearance of craniopharyngioma on computed tomography

    International Nuclear Information System (INIS)

    Danziger, A.; Price, H.I.

    1979-01-01

    Craniopharyngiomas present a diverse appearance on computed tomography. Histological diagnosis is not always possible, but computed tomography is of great assistance in the delineation of the tumour as well as of the degree of associated hydrocephalus. Computed tomography also enables rapid non-invasive follow-up after surgery or radiotherapy, or both

  14. Measuring Weld Profiles By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Noncontacting, nondestructive computer tomography system determines internal and external contours of welded objects. System makes it unnecessary to take metallurgical sections (destructive technique) or to take silicone impressions of hidden surfaces (technique that contaminates) to inspect them. Measurements of contours via tomography performed 10 times as fast as measurements via impression molds, and tomography does not contaminate inspected parts.

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... information about radiation dose. There always is a risk of complications from general anesthesia or sedation. Every measure will be taken to ... in X-Ray and CT Exams Contrast Materials Anesthesia Safety Children and Radiation Safety ... (Pediatric) CT (Computed Tomography) Videos related to Children's (Pediatric) ...

  16. Computed tomography of cartilaginous tumours

    International Nuclear Information System (INIS)

    Marincek, B.; Triller, J.; Robotti, G.; Gumppenberg, S. von

    1984-01-01

    The compound tomography (CT) morphology of cartilaginous tumors and the utility of CT in their diagnostic work-up is presented on the basis of 19 cases. CT provided unique informations regarding definition of tumor extent and tumor relationship to adjacent structures particularly in the axial skeleton. CT has diminished the indications for angiography in cartilaginous tumors. (orig.) [de

  17. Robustness of raw quantum tomography

    Science.gov (United States)

    Asorey, M.; Facchi, P.; Florio, G.; Man'ko, V. I.; Marmo, G.; Pascazio, S.; Sudarshan, E. C. G.

    2011-01-01

    We scrutinize the effects of non-ideal data acquisition on the tomograms of quantum states. The presence of a weight function, schematizing the effects of a finite window or equivalently noise, only affects the state reconstruction procedure by a normalization constant. The results are extended to a discrete mesh and show that quantum tomography is robust under incomplete and approximate knowledge of tomograms.

  18. Robustness of raw quantum tomography

    Energy Technology Data Exchange (ETDEWEB)

    Asorey, M. [Departamento de Fisica Teorica, Facultad de Ciencias, Universidad de Zaragoza, 50009 Zaragoza (Spain); Facchi, P. [Dipartimento di Matematica, Universita di Bari, I-70125 Bari (Italy); INFN, Sezione di Bari, I-70126 Bari (Italy); MECENAS, Universita Federico II di Napoli and Universita di Bari (Italy); Florio, G. [Dipartimento di Fisica, Universita di Bari, I-70126 Bari (Italy); INFN, Sezione di Bari, I-70126 Bari (Italy); MECENAS, Universita Federico II di Napoli and Universita di Bari (Italy); Man' ko, V.I., E-mail: manko@lebedev.r [P.N. Lebedev Physical Institute, Leninskii Prospect 53, Moscow 119991 (Russian Federation); Marmo, G. [Dipartimento di Scienze Fisiche, Universita di Napoli ' Federico II' , I-80126 Napoli (Italy); INFN, Sezione di Napoli, I-80126 Napoli (Italy); MECENAS, Universita Federico II di Napoli and Universita di Bari (Italy); Pascazio, S. [Dipartimento di Fisica, Universita di Bari, I-70126 Bari (Italy); INFN, Sezione di Bari, I-70126 Bari (Italy); MECENAS, Universita Federico II di Napoli and Universita di Bari (Italy); Sudarshan, E.C.G. [Department of Physics, University of Texas, Austin, TX 78712 (United States)

    2011-01-31

    We scrutinize the effects of non-ideal data acquisition on the tomograms of quantum states. The presence of a weight function, schematizing the effects of a finite window or equivalently noise, only affects the state reconstruction procedure by a normalization constant. The results are extended to a discrete mesh and show that quantum tomography is robust under incomplete and approximate knowledge of tomograms.

  19. Computed tomography in hepatic echinococcosis

    International Nuclear Information System (INIS)

    Choliz, J.D.; Olaverri, F.J.L.; Casas, T.F.; Zubieta, S.O.

    1982-01-01

    Computed tomography (CT) was used to evaluate 50 cases of hydatid disease of the liver. It was definite in 49 cases and negative in one case. Pre- and postcontrast scans were performed. CT may reveal the exact location and extension of cysts and possible complications. However, a false-negative case was found in a hydatid cyst located in a fatty liver

  20. Computer tomography in Caisson's disease

    International Nuclear Information System (INIS)

    Horvath, F.; Csobaly, S.; Institute for Advanced Training of Physicians, Budapest

    1981-01-01

    Computer tomography was performed on 20 patients with the early stages of Caisson osteoarthropathy, as well as in other patients with chronic bone infarcts. From their results the authors have formed the opinion that CT is valuable, not only in the diagnosis of early cases, but that it can provide significant information concerning the osteopathy and bone infarcts. (orig.) [de

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  2. Laryngopyocele: signs on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nazaroglu, Hasan E-mail: hnazarog@dicle.edu.tr; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual.

  3. Laryngopyocele: signs on computed tomography

    International Nuclear Information System (INIS)

    Nazaroglu, Hasan; Oezates, Mustafa; Uyar, Asur; Deger, Emin; Simsek, Masum

    2000-01-01

    A laryngocele is an air-filled dilation of the saccule of the larynx. An infected laryngocele is called a laryngopyocele. Our experience with a case of laryngopyocele with signs on computed tomography before and after antibiotic therapy is presented since laryngopyocele is more unusual

  4. X-ray Computed Tomography.

    Science.gov (United States)

    Michael, Greg

    2001-01-01

    Describes computed tomography (CT), a medical imaging technique that produces images of transaxial planes through the human body. A CT image is reconstructed mathematically from a large number of one-dimensional projections of a plane. The technique is used in radiological examinations and radiotherapy treatment planning. (Author/MM)

  5. Industrial applications of computed tomography

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Kruth, J. -P.

    2014-01-01

    The number of industrial applications of Computed Tomography(CT) is large and rapidly increasing. After a brief market overview, the paper gives a survey of state of the art and upcoming CT technologies, covering types of CT systems, scanning capabilities, and technological advances. The paper...

  6. Maximum entropy beam diagnostic tomography

    International Nuclear Information System (INIS)

    Mottershead, C.T.

    1985-01-01

    This paper reviews the formalism of maximum entropy beam diagnostic tomography as applied to the Fusion Materials Irradiation Test (FMIT) prototype accelerator. The same formalism has also been used with streak camera data to produce an ultrahigh speed movie of the beam profile of the Experimental Test Accelerator (ETA) at Livermore. 11 refs., 4 figs

  7. Maximum entropy beam diagnostic tomography

    International Nuclear Information System (INIS)

    Mottershead, C.T.

    1985-01-01

    This paper reviews the formalism of maximum entropy beam diagnostic tomography as applied to the Fusion Materials Irradiation Test (FMIT) prototype accelerator. The same formalism has also been used with streak camera data to produce an ultrahigh speed movie of the beam profile of the Experimental Test Accelerator (ETA) at Livermore

  8. MR tomography in Kallmann's syndrome

    International Nuclear Information System (INIS)

    Dewes, W.; Krahe, T.; Klingmueller, D.; Harder, T.; Bonn Univ.

    1987-01-01

    MR tomography is the only imaging method that can demonstrate atrophy of the olfactory lobe of the brain in olfacto-genital dysplasia (Kallmann's syndrome). The MRT findings in five patients with Kallmann's syndrome are described. The MRT criterion for the presence of Kallmann's syndrome appears to be an interruption or total absence of the olfactory sulcus. (orig.) [de

  9. Positron computed tomography with fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Hervouet, T.; Kraeber-Bodere, F.; Lamy, T.; Le Gouil, S.; Devillers, A.; Bodet-Milin, C.; Ansquer, C.; Cheze-le Rest, C.; Metges, J.P.; Teyton, P.; Lozach, P.; Volant, A.; Bizais, Y.; Visvikis, D.; Morel, O.; Girault, S.; Soulie, P.; Dupoiron, D.; Berthelot, C.; Lorimier, G.; Jallet, P.; Garin, E.; Prigent, F.; Lesimple, T.; Barge, M.L.; Rousseau, C.; Devillers, A.; Bernard, A.M.; Bouriel, C.; Bridji, B.; Resche, R.; Banayan, S.; Claret, M.; Ninet, J.; Janier, M.; Billotey, C.; Garin, E.; Devillers, A.; Becker, S.; Lecloirec, J.; Boucher, E.; Raoul, J.L.; Rolland, V.; Oudoux, A.; Valette, F.; Dupas, B.; Moreau, P.; Champion, L.; Anract, P.; Wartski, M.; Laurence, V.; Goldwasser, F.; Pecking, A.P.; Alberini, J.L.; Brillouet, S.; Caselles, O.; Allal, B.; Zerdoud, S.; Gansel, M.G.; Thomas, F.; Dierrickx, L.; Delord, J.P.; Marchand, C.; Resche, I.; Mahe, M.A.

    2006-01-01

    Several oral communications present the interest of positron computed tomography with fluorodeoxyglucose in the detection of cancers, or for the follow up of cancers treatments in order to detect early possible relapses.PET FDG is also used to optimize the definition of target volume in order to avoid side effects and to get a better control of the illness. (N.C.)

  10. Efeito da eutonia no tratamento da fibromialgia

    OpenAIRE

    Maeda,Cecília; Martinez,José Eduardo; Neder,Matilde

    2006-01-01

    OBJETIVO: avaliar a eutonia como método terapêutico auxiliar no tratamento da fibromialgia (FM). MÉTODOS: estudou-se um grupo de 20 mulheres, segundo os critérios do American College of Rheumatology (ACR), com duração mínima de seis meses, sem alterações no tratamento medicamentoso ou prescrição de exercícios nesse período. As pacientes foram avaliadas através do questionário de dados sociodemográficos; Escala Visual Analógica (EVA) para dor e questionário genérico de avaliação da qualidade d...

  11. Het Italiaanse voorzetsel da

    NARCIS (Netherlands)

    Boer, M.G. de

    2010-01-01

    SAMENVATTING In een voorzetselstudie in het kader van Jackendoffs semantische theorie wordt het sterk polyseme Italiaanse voorzetsel da geanalyseerd als een verzameling deelbetekenissen waarbij de meeste door een of meer semantische regels afgeleid kunnen worden van de basisbetekenis ruimtelijke

  12. ESPECTROS INFRAVERMELHOS DA CREATINA

    Directory of Open Access Journals (Sweden)

    Kumiko K. Sakane

    2011-08-01

    Full Text Available São apresentados espectros infravermelhos da creatina, na faixa de 4000 a 400 cm−1. Os resultados são comparados com espectros observados e calculados, publicados na literatura.

  13. Significados Ocultos da Enfermagem

    Directory of Open Access Journals (Sweden)

    Wiliam César alves Machado

    2011-04-01

    Full Text Available Sabe-se que as ações de cuidar em enfermagem foram sendo moldadas através da história da humanidade e deram-se, majoritariamente, na esfera do subjetivo que permeia as interações existenciais do ser humano que cuida e daquele que recebe cuidados. Campo fecundo para intercâmbios eletromagnéticos. Suas origens remontam ao cuidado prestado por mães, pais, avós, irmãos e demais familiares incumbidos da responsabilidade de ajudar entes recém-natos, crianças, doentes e idosos em suas necessidades de cuidados para preservação da vida.

  14. ORIGEM DA ANGTIA MODERNA

    Directory of Open Access Journals (Sweden)

    Edvino Rabuske

    1971-01-01

    Full Text Available O tema que me foi proposto "origem da angtia moderna". Por certo, um tema extremamente complexo. Trata-se de surpreender as modalidades modernas de um fenomeno, antigo como o prrio homem. Visando contribuir numa semana de reflexo sobre a esperan crist em, que esta abordada a partir, de diversos gulos, parece indicado que esta exposio n se atenha a um ico aspeto da angtia.

  15. Computed tomography to evaluate the association of fragmented heterolog cortical bone and methylmethacrylate to repare segmental bone defect produced in tibia of rabbits; Tomografia computadorizada da matriz ossea mineralizada heterologa fragmentada e metilmetacrilato na reparacao de falhas osseas segmentares produzidas em tibia de coelhos

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, S.H. [Universidade Federal de Sao Paulo (USP), SP (Brazil); Doria, R.G.S. [Universidade Federal de Sao Paulo (USP), SP (Brazil). Faculdade de Zootecnia e Engenharia de Alimentos; Mendonca, F.S.; Santos, M.D.; Moreira, R. [Universidade de Cuiaba, MT (Brazil). Faculdade de Medicina Veterinaria; Simoes, R.S. [Universidade Federal de Sao Paulo (USP), SP (Brazil). Hospital Universitario; Camargo, L.M.; Simoes, M.J. [Universidade Federal de Sao Paulo (USP), SP (Brazil). Escola Paulista de Medicina; Marques, A.T.C. [Universidade de Cuiaba, MT (Brazil). Faculdade de Odontologia

    2012-11-15

    A 6mm segmental defect was performed on the metaphyseal region of the tibia of 12 rabbits and the autoclaved fragmented heterolog cortical bone conserved in glycerin (98%) and methylmethacrylate was used as a bone graft for the reconstruction. The graft was placed in the receptor bed and its integration was evaluated by computed tomography after 30, 60 and 90 days. There was gradual bone graft incorporation in the receptor bed during the time in 100% of the cases. Fragmented cortical bone heterograft and methylmethacrylate was biologically compatible and promotes bone defect reparation without signs of infection, migration and or rejection, featuring a new option of osseous substitute to fill in bone defects. (author)

  16. Single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.

    1986-01-01

    Single photon tomography dates from the early 1960's when the idea of emission transverse section tomography was presented by Kuhl and Edwards. They used a rectilinear scanner and analogue back-projection methods to detect emissions from a series of sequential positions transverse to the cephaldcaudad axis of the body. This chapter presents an explanation of emission tomography by describing longitudinal and transverse section tomography. In principle all modes of tomography can be considered under the general topic of coded apertures wherein the code ranges from translation of a pinhole collimator to rotation of a parallel hole or focused collimator array

  17. Real-time three-dimensional echocardiographic left ventricular ejection fraction and volumes assessment: comparison with cardiac computed tomography; Comparacao entre a afericao da fracao de ejecao e dos volumes do ventriculo esquerdo, medidos com ecocardiografia tridimensional em tempo real e com tomografia computadorizada ultra-rapida

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Marcelo L.C.; Nomura, Cesar H.; Tranchesi Junior, Bernardino; Oliveira, Wercules A. de; Naccarato, Gustavo; Serpa, Bruna S.; Cury, Alexandre; Passos, Rodrigo B.D.; Nobrega, Marcel V. da; Funari, Marcelo B.G.; Pfefermam, Abhaham; Makdisse, Marcia; Fischer, Claudio H.; Morhy, Samira S., E-mail: luiz766@terra.com.br [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil)

    2008-10-15

    Background and objective: Few studies addressed the comparison between real-time 3D echocardiography (RT3DE) and cardiac computed tomography (CCT) concerning left ventricular ejection fraction and volumes assessment. We sought to compare both techniques regarding left ventricle (LV) ejection fraction function and volumes analysis. Methods: we studied by RT3DE (Philips IE 33, And, MA, USA) and by CCT (Toshiba, 64-slice, Otawara, Japan) 41 consecutive patients (29 males, 58 ± 11 yrs). We analysed by both techniques LVEF, LVEDV, LVESV. RT3DE and CCT data were compared by coefficients of determination (r: Pearson), Bland and Altman test and linear regression, 95% CI. Results: RT3DE data: LVEF ranged from 56.7 to 78.9 % (65.3 + 5.7 ); LVEDV ranged from 49.6 to 178.2 (88 + 27.5) mL; LVESV from 11.4 to 78 ( 33.9 + 13.7) mL. CCT data: LVEF ranged from 53 to 86 % (67.3 + 7.9 ); LVEDV ranged from 51 to 186 (106.4 + 30.7) mL; LVESV from 7 to 72 ( 35.1 + 13.8) mL. Correlations relative to RT3DE and CCT were: LVEF (r: 0. 7877, p<0.0001, 95 % CI 0.6327 to 0.8853 ); LVEDV (r:0.7671, p<0.0001, 95 % CI 0.5974 to 0.8745); LVESV (r: 0.8121, p<0.0001, 95 % CI 0.6659 to 0.8957). Conclusions: it was observed adequate correlation between real-time 3D echocardiography and cardiac computed tomography concerning ejection fraction and volumes assessment. (author)

  18. Evaluation of conformal radiotherapy techniques through physics and biologic criteria; Avaliacao de tecnicas radioterapicas conformacionais utilizando criterios fisicos e biologicos

    Energy Technology Data Exchange (ETDEWEB)

    Bloch, Jonatas Carrero

    2012-07-01

    In the fight against cancer, different irradiation techniques have been developed based on technological advances and aiming to optimize the elimination of tumor cells with the lowest damage to healthy tissues. The radiotherapy planning goal is to establish irradiation technical parameters in order to achieve the prescribed dose distribution over the treatment volumes. While dose prescription is based on radiosensitivity of the irradiated tissues, the physical calculations on treatment planning take into account dosimetric parameters related to the radiation beam and the physical characteristics of the irradiated tissues. To incorporate tissue's radiosensitivity into radiotherapy planning calculations can help particularize treatments and establish criteria to compare and elect radiation techniques, contributing to the tumor control and the success of the treatment. Accordingly, biological models of cellular response to radiation have to be well established. This work aimed to study the applicability of using biological models in radiotherapy planning calculations to aid evaluating radiotherapy techniques. Tumor control probability (TCP) was studied for two formulations of the linear-quadratic model, with and without repopulation, as a function of planning parameters, as dose per fraction, and of radiobiological parameters, as the α/β ratio. Besides, the usage of biological criteria to compare radiotherapy techniques was tested using a prostate planning simulated with Monte Carlo code PENELOPE. Afterwards, prostate planning for five patients from the Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto, USP, using three different techniques were compared using the tumor control probability. In that order, dose matrices from the XiO treatment planning system were converted to TCP distributions and TCP-volume histograms. The studies performed allow the conclusions that radiobiological parameters can significantly influence tumor control

  19. Use of an improved simultaneous tomography cassette in linear tomography

    International Nuclear Information System (INIS)

    Egender, G.; Pirker, E.; Gornik, E.; Innsbruck Univ.

    1984-01-01

    An improved simultaneous tomography cassette according to P. Landau was tried out for four months using four tomographs in routine work. The mode of operation is based on accurate control of the relative speeds of the individual x-ray films resulting in simultaneous imaging of 6 equidistant tomographic levels. Clinical testing was effected in 80 cases: nephrotomography, of the lungs, the hilum, and the skeleton. In particular, the article describes imaging of the renal arteries by simultaneous tomography for the purpose of finding out the cause of hypertension, and if there is suspicion of a space-occupying growth in the kidney, basing on the urogram. The specific advantages of this technique are, on the one hand, improved diagnostic efficiency (the tomograms are taken during the same respiratory phase, more rapid diagnosis especially with accident patients), and, on the other hand, an important reduction in the x-ray exposure of the patient; furthermore, the life of the x-ray tube is prolonged, and there is a definite saving of time for both patient and personnel, the image quality being comparable with that of single-layer tomography. (orig.) [de

  20. As dobras da imagem

    Directory of Open Access Journals (Sweden)

    Profª. Drª. Fátima Antunes da Silva (Yaska Antunes

    2009-05-01

    Full Text Available O presente trabalho tem por objetivo tentar compreender a produção da imagem visual no teatro. Para isso se vale da apropriação livre do conceito de “dobra? de Gilles Deleuze para se referir à multiplicidade de imagens criadas pelas diversas modalidades artísticas. Como no teatro há o entrelaçamento de imagens verbais – palavras enunciadas pelo texto dramático ou teatral – com imagens visuais – a visualidade advinda da composição cênica concreta que organiza no espaço ator e objeto –, a ênfase só podia recair sobre estas duas formas imagéticas. No caso do teatro, surge ainda a percepção de que para além da materialidade da cena, outras imagens emergem do confronto entre palco e platéia. Nesse sentido, imagem teatral seria então aquilo que surge da interação entre ator e espectador. A contribuição desse trabalho pode estar no fato de atualizar certos conceitos sobre a criação da imagem poética na poesia e no cinema para aplicá-los ao teatro. Ao recuperar o pensa-mento de Otávio Paz, Alfredo Bosi, Sergei Eisenstein, entre outros, bus-ca-se promover uma reflexão mais aprofundada sobre a construção visual no teatro.

  1. Massively parallel diffuse optical tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sandusky, John V.; Pitts, Todd A.

    2017-09-05

    Diffuse optical tomography systems and methods are described herein. In a general embodiment, the diffuse optical tomography system comprises a plurality of sensor heads, the plurality of sensor heads comprising respective optical emitter systems and respective sensor systems. A sensor head in the plurality of sensors heads is caused to act as an illuminator, such that its optical emitter system transmits a transillumination beam towards a portion of a sample. Other sensor heads in the plurality of sensor heads act as observers, detecting portions of the transillumination beam that radiate from the sample in the fields of view of the respective sensory systems of the other sensor heads. Thus, sensor heads in the plurality of sensors heads generate sensor data in parallel.

  2. Instrumentation for positron emission tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Derenzo, S.E.; Huesman, R.H.

    1984-01-01

    Positron emission tomography with a spatial resolution of 2 mm full width at half maximum for quantitation in regions of interest 4 mm in diameter will become possible with the development of detectors that achieve ultrahigh resolution. Improved resolution will be possible using solid-state photodetectors for crystal identification or photomultiplier tubes with many small electron multipliers. Temporal resolution of 2 seconds and gating of cyclic events can be accomplished if statistical requirements are met. The major physical considerations in achieving high-resolution positron emission tomography are the degradation in resolution resulting from positron range, emission angle, parallax error, detector sampling density, the sensitivity of various detector materials and packing schemes, and the tradeoff between temporal resolution and statistical accuracy. The accuracy of data required for physiological models depends primarily on the fidelity of spatial sampling independent of statistical constraints

  3. Single photon emission computerized tomography

    International Nuclear Information System (INIS)

    Hooge, P. de.

    1983-01-01

    In this thesis two single-photon emission tomographic techniques are presented: (a) longitudinal tomography with a rotating slanting-hole collimator, and (b) transversal tomography with a rotating gamma camera. These methods overcome the disadvantages of conventional scintigraphy. Both detection systems and the image construction methods are explained and comparisons with conventional scintigraphy are drawn. One chapter is dedicated to the determination of system parameters like spatial resolution, contrast, detector uniformity, and size of the object, by phantom studies. In separate chapters the results are presented of detection of tumors and metastases in the liver and the liver hilus; skeletal diseases; various pathological aberrations of the brain; and myocardial perfusion. The possible use of these two ect's for other organs and body areas is discussed in the last chapter. (Auth.)

  4. Computerised tomography in radiotherapy planning

    International Nuclear Information System (INIS)

    Badcock, P.C.

    1983-01-01

    This study evaluates the effectiveness of computed tomography as an adjunct to radiotherapy planning. Until recently, acquisition of accurate data concerning tumour anatomy lagged behind other developments in radiotherapy. With the advent of computer-tomography (CT), these data can be displayed and transmitted to a treatment planning computer. It is concluded that the greatest inaccuracies in the radiation treatment of patients are to be found in both the inadequate delineation of the target volume within the patient and changes in body outline relative to the target volume over the length of the irradiated volume. The technique was useful in various subgroups (pelvic, intra-thoracic and chest-wall tumours) and for those patients being treated palliatively. With an estimated improvement in cure rate of 4.5% and cost-effective factors of between 3.3 and 5, CT-assisted radiotherapy planning appears to be a worthwhile procedure. (orig.)

  5. Industrial applications of computer tomography

    International Nuclear Information System (INIS)

    Sheng Kanglong; Qiang Yujun; Yang Fujia

    1992-01-01

    Industrial computer tomography (CT) and its application is a rapidly developing field of high technology. CT systems have been playing important roles in nondestructive testing (NDT) of products and equipment for a number of industries. Recently, the technique has advanced into the area of industrial process control, bringing even greater benefit to mankind. The basic principles and typical structure of an industrial CT system Descriptions are given of some successful CT systems for either NDT application or process control purposes

  6. Computed tomography of projectile injuries

    International Nuclear Information System (INIS)

    Jeffery, A.J.; Rutty, G.N.; Robinson, C.; Morgan, B.

    2008-01-01

    Computed tomography (CT) is a gold standard in clinical imaging but forensic professions have been slow to embrace radiological advances. Forensic applications of CT are now exponentially expanding, replacing other imaging methods. As post-mortem cross-sectional imaging increases, radiologists will fall under increasing pressure to interpret complex forensic cases involving both living and deceased patients. This review presents a wide variety of weapon and projectile types aiding interpretation of projectile injuries both in forensic and clinical practice

  7. Positron emission tomography. Basic principles

    International Nuclear Information System (INIS)

    Rodriguez, Jose Luis; Massardo, Teresa; Gonzalez, Patricio

    2001-01-01

    The basic principles of positron emission tomography (PET) technique are reviewed. lt allows to obtain functional images from gamma rays produced by annihilation of a positron, a positive beta particle. This paper analyzes positron emitters production in a cyclotron, its general mechanisms, and the various detection systems. The most important clinical applications are also mentioned, related to oncological uses of fluor-l8-deoxyglucose

  8. Viewing Welds By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Computer tomography system used to inspect welds for root penetration. Source illuminates rotating welded part with fan-shaped beam of x rays or gamma rays. Detectors in circular array on opposite side of part intercept beam and convert it into electrical signals. Computer processes signals into image of cross section of weld. Image displayed on video monitor. System offers only nondestructive way to check penetration from outside when inner surfaces inaccessible.

  9. Quantitative inspection by computerized tomography

    International Nuclear Information System (INIS)

    Lopes, R.T.; Assis, J.T. de; Jesus, E.F.O. de

    1989-01-01

    The computerized Tomography (CT) is a method of nondestructive testing, that furnish quantitative information, that permit the detection and accurate localization of defects, internal dimension measurement, and, measurement and chart of the density distribution. The CT technology is much versatile, not presenting restriction in relation to form, size or composition of the object. A tomographic system, projected and constructed in our laboratory is presented. The applications and limitation of this system, illustrated by tomographyc images, are shown. (V.R.B.)

  10. Computed tomography in osteoid osteoma

    International Nuclear Information System (INIS)

    Vicens, J.L.; Aubspin, D.; Buchon, R.; Schoenenberger, P.; Flageat, J.

    1989-01-01

    Four cases of suspected osteoid osteoma were evaluated by computed tomography (CT). The role of CT was related, as a key diagnostic tool: radionuclide imaging is helpful in directing subsequent CT scans, which allows the study of complex anatomical sites (spine) or the analysis of atypical lesions (invisible nidus, sclerosis or lytic lesions, double nidus...). CT provides the surgeon with the exact location and extent of the lesion, and thus, CT may allow a more limited surgical resection of the involved bone [fr

  11. Inherent Limitations of Hydraulic Tomography

    Science.gov (United States)

    Bohling, Geoffrey C.; Butler, J.J.

    2010-01-01

    We offer a cautionary note in response to an increasing level of enthusiasm regarding high-resolution aquifer characterization with hydraulic tomography. We use synthetic examples based on two recent field experiments to demonstrate that a high degree of nonuniqueness remains in estimates of hydraulic parameter fields even when those estimates are based on simultaneous analysis of a number of carefully controlled hydraulic tests. We must, therefore, be careful not to oversell the technique to the community of practicing hydrogeologists, promising a degree of accuracy and resolution that, in many settings, will remain unattainable, regardless of the amount of effort invested in the field investigation. No practically feasible amount of hydraulic tomography data will ever remove the need to regularize or bias the inverse problem in some fashion in order to obtain a unique solution. Thus, along with improving the resolution of hydraulic tomography techniques, we must also strive to couple those techniques with procedures for experimental design and uncertainty assessment and with other more cost-effective field methods, such as geophysical surveying and, in unconsolidated formations, direct-push profiling, in order to develop methods for subsurface characterization with the resolution and accuracy needed for practical field applications. Copyright ?? 2010 The Author(s). Journal compilation ?? 2010 National Ground Water Association.

  12. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  13. Trauma da Veia Porta

    Directory of Open Access Journals (Sweden)

    Gustavo Pereira Fraga

    Full Text Available OBJETIVO: O trauma da veia porta é raro e freqüentemente fatal por causa de exsanguinação e alta incidência de lesões de estruturas adjacentes. Devido às pecualiaridades desta lesão e diferentes condutas propostas na literatura, o objetivo dos autores é relatar a experiência neste tipo de lesão. MÉTODO: Estudo retrospectivo, de janeiro de 1994 e dezembro de 2001, de 1370 pacientes submetidos à laparotomia devido trauma abdominal. Entre esses, 15 pacientes apresentavam lesão da veia porta. As lesões foram classificadas conforme a sua extensão e localização. RESULTADOS: O mecanismo de trauma predominante foi o penetrante. O diagnóstico da lesão foi realizado no intraoperatório. Os procedimentos executados foram: sutura, anastomose término-terminal e ligadura da veia porta. A mortalidade foi de 53,3%. CONCLUSÃO: A lesão da veia porta possui alta taxa de mortalidade e o atendimento adequado está diretamente relacionado à sobrevida.

  14. Diagnosis and evaluation of surveying examination by intracranial tumor in dogs CT; Diagnostico e avaliacao topografica de neoplasias intracranianas pelo exame de TC em caes

    Energy Technology Data Exchange (ETDEWEB)

    Romaldini, Andre Fonseca; Santos, Debora Rodrigues dos; Oliveira, Juliana Messias; Abreu, Felipe Andrei Suarez; Wallace, Verena; Pacheco, Eduardo Nelson da Silva, E-mail: andreromaldini@gmail.com [Hospital Santa Ines de Sao Paulo, Santana, SP (Brazil)

    2012-07-01

    The use of computed tomography (CT) revolutionized image diagnostic in veterinary medicine and currently can be considered one of the most useful tools for the imaging evaluation of intracranial tumor in dogs. Computed tomography of the brain in small animals allows visualization of intracranial tumor, compression of adjacent structures such as cerebral parenchyma, falx or lateral ventricles, and evaluate secondary hemorrhages and edema. The CT imaging provides essential information to indicate the surgical approach for a possible tumor resection or biopsy, including the correct location and boundaries structures involved, and also can be used to monitor the clinical treatment. However, only histopathological examination is able to confirm the final diagnosis. (author)

  15. Computed-tomography-guided anatomic standardization for quantitative assessment of dopamine transporter SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Kota [National Center of Neurology and Psychiatry, Department of Radiology, Tokyo (Japan); National Center of Neurology and Psychiatry, Integrative Brain Imaging Center, Tokyo (Japan); Imabayashi, Etsuko; Matsuda, Hiroshi [National Center of Neurology and Psychiatry, Integrative Brain Imaging Center, Tokyo (Japan); Sumida, Kaoru; Sone, Daichi; Kimura, Yukio; Sato, Noriko [National Center of Neurology and Psychiatry, Department of Radiology, Tokyo (Japan); Mukai, Youhei; Murata, Miho [National Center of Neurology and Psychiatry, Department of Neurology, Tokyo (Japan)

    2017-03-15

    For the quantitative assessment of dopamine transporter (DAT) using [{sup 123}I]FP-CIT single-photon emission computed tomography (SPECT) (DaTscan), anatomic standardization is preferable for achieving objective and user-independent quantification of striatal binding using a volume-of-interest (VOI) template. However, low accumulation of DAT in Parkinson's disease (PD) would lead to a deformation error when using a DaTscan-specific template without any structural information. To avoid this deformation error, we applied computed tomography (CT) data obtained using SPECT/CT equipment to anatomic standardization. We retrospectively analyzed DaTscan images of 130 patients with parkinsonian syndromes (PS), including 80 PD and 50 non-PD patients. First we segmented gray matter from CT images using statistical parametric mapping 12 (SPM12). These gray-matter images were then anatomically standardized using the diffeomorphic anatomical registration using exponentiated Lie algebra (DARTEL) algorithm. Next, DaTscan images were warped with the same parameters used in the CT anatomic standardization. The target striatal VOIs for decreased DAT in PD were generated from the SPM12 group comparison of 20 DaTscan images from each group. We applied these VOIs to DaTscan images of the remaining patients in both groups and calculated the specific binding ratios (SBRs) using nonspecific counts in a reference area. In terms of the differential diagnosis of PD and non-PD groups using SBR, we compared the present method with two other methods, DaTQUANT and DaTView, which have already been released as software programs for the quantitative assessment of DaTscan images. The SPM12 group comparison showed a significant DAT decrease in PD patients in the bilateral whole striatum. Of the three methods assessed, the present CT-guided method showed the greatest power for discriminating PD and non-PD groups, as it completely separated the two groups. CT-guided anatomic standardization using

  16. Three-dimensional evaluation of human jaw bone microarchitecture: correlation between the microarchitectural parameters of cone beam computed tomography and micro-computer tomography.

    Science.gov (United States)

    Kim, Jo-Eun; Yi, Won-Jin; Heo, Min-Suk; Lee, Sam-Sun; Choi, Soon-Chul; Huh, Kyung-Hoe

    2015-12-01

    To evaluate the potential feasibility of cone beam computed tomography (CBCT) in the assessment of trabecular bone microarchitecture. Sixty-eight specimens from four pairs of human jaw were scanned using both micro-computed tomography (micro-CT) of 19.37-μm voxel size and CBCT of 100-μm voxel size. The correlation of 3-dimensional parameters between CBCT and micro-CT was evaluated. All parameters, except bone-specific surface and trabecular thickness, showed linear correlations between the 2 imaging modalities (P < .05). Among the parameters, bone volume, percent bone volume, trabecular separation, and degree of anisotropy (DA) of CBCT images showed strong correlations with those of micro-CT images. DA showed the strongest correlation (r = 0.693). Most microarchitectural parameters from CBCT were correlated with those from micro-CT. Some microarchitectural parameters, especially DA, could be used as strong predictors of bone quality in the human jaw. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Da Vinci Linjen

    DEFF Research Database (Denmark)

    Nissen, Poul

    Afsluttende evalueringsrapport fra følgeforskningen gennem tre år i forbindelse med dety pædagogiske arbejde på Blåbjerggårdskolens Da Vinci Linje for skolemotiverede og underpræsterende elever på 7. til 9. klassetrin.......Afsluttende evalueringsrapport fra følgeforskningen gennem tre år i forbindelse med dety pædagogiske arbejde på Blåbjerggårdskolens Da Vinci Linje for skolemotiverede og underpræsterende elever på 7. til 9. klassetrin....

  18. Imaging of acquired non-traumatic cochlear lesions: iconographic essay; Avaliacao por imagem das lesoes cocleares adquiridas (nao-traumaticas): ensaio iconografico

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, Marcelo de Mattos; Gonzaga, Juliana Gontijo [Clinica Axial - Centro de Imagem, Belo Horizonte, MG (Brazil)]. E-mail: cidbh@cidbh.com.br; marcelogarcia@superig.com.br

    2006-04-15

    Different non-traumatic acquired cochlear lesions are shown in this article with imaging methods. They may be responsible for neuro sensorial hearing loss or vertigo. The method of choice is computed tomography when evaluating the osseous labyrinth whereas magnetic resonance imaging has superior resolution in the studies of the membranaceous labyrinth. (author)

  19. Tomography assessment of lung hyper inflation areas within cats in a pressure controlled ventilation staggered; Avaliacao tomografica das areas de de hiperinsuflacao pulmonar em gatos submetidos a ventilacao controlada a pressao escalonada

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Alessandro Rodrigues de Carvalho, E-mail: doutorevet@hotmail.com [Universidade de Sao Paulo (FM/USP), SP (Brazil). Faculdade de Medicina. Programa de Anestesiologia; Fantoni, Denise Tabacchi; Ambrosio, Aline Magalhaes [Universidade de Sao Paulo (FMVZ/USP), SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia; Santos, Jaqueline Franca dos; Villamizar, Lenin Arturo [Universidade de Sao Paulo (FMVZ/USP), SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Programa de Cirurgia; Pinto, Ana Carolina Brandao de Campos Fonseca [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Disciplina de Diagnostico por Imagem; Martins, Thiago do Amaral [UFAPE Vet Intenziv, Itapecerica da Serra, SP (Brazil); Malbouisson, Luis Marcelo Sa [Universidade de Sao Paulo (HC/USP), SP (Brazil). Faculdade de Medicina. UTI Anestesiologica

    2012-07-01

    Mechanical ventilation is essential for oxygen supply during anesthesia. Some strategies are related to lung injury associated with mechanical ventilation. 10 cats, 4±1 kg, 1-6 years old, induced and maintained with propofol (6mg/kg, 0,5mg/kg/min) placed in supine position, subjected to pressure controlled ventilation (PCV) in oxygen at 40% with 5cmH{sub 2}O peak pressure in 'ZEEP' for 20 minutes, rising in 2cmH{sub 2}O installments peak pressure every five minutes until it reached 15cmH{sub 2}O. Moments P5, P7, P9, P11, P13, P15. Respiratory rate and inspiratory time were held on 15 movements per minute and 1 second regardless their EtCO{sub 2}. Muscle relaxation achieved by rocuronium bollus (1mg/kg/IV). Immediately, at each increase on pressure was performed a 4 seconds' inspiratory pause to allow the five millimeters CT slice of diaphragmatic region followed by hemogasometric and cardiorespiratory variables collected. P5 had the smallest hyperinflated area (3,24±4,02) Compared to other moments. P5 blood gases showed acidaemia (7,257±0,08) for mild respiratory acidosis (45±9.2) with good oxygenation (178±40.8mmHg) compared to other times which obtained reduction of CO{sub 2} and an increased pH. As the increase in peak pressure was observed increased distension of the lung parenchyma, a fact related to possible risk of lung injury in prolonged periods. 5cmH{sub 2}O pressure was demonstrated to be less harmful due to its lower hyper inflated areas that other moments, even with a low pH and high CO{sub 2}, being corrected by increasing respiratory rate.

  20. Preliminary evaluation of exposures of computerized tomography patients in Latin America: IAEA project RLA/9/67; Avaliacao preliminar das exposicoes de pacientes em tomografia computadorizada na America Latina: Projeto IAEA RLA/9/67

    Energy Technology Data Exchange (ETDEWEB)

    Kodlulovich, S.; Silveira, V. [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Khoury, H.J. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamcnto de Energia Nuclear; and others

    2013-07-01

    The aim of this study was to obtain preliminary values of reference levels in CT . Were sent to each country forms with information of radiological protection and routine CT protocols. The CT dose index and absorbed dose to organs was estimated from the technical data for each equipment . The results showed that the total number of examinations performed 92 % are adult patients and 8 % are children. The most frequent examination of the skull was adult (40 % ) and abdomen for children (42 % ) . About the service , 67 % of the equipment are multicut and 76 % have specific protocols for pediatric patients. The CTDI{sub vol} values for head exams of adults vary between 2 and 352 mGy for pediatric patients under 1 year 1-191 mGy under 7 years old 5-335 mGy. For chest values ranged from 3 to 26 mGy for adults, between 1 and 89 mGy for children under 1 year and between 3-114 mGy for children between 1 and 7 years. Exams of the abdomen/pelvis of adults the range was 3-47 mGy , between 4-90 mGy for children under 1 year and between 2-31 mGy for children between 1 and 7 years. This study showed that although there are pediatric protocols, there is a wide variation in values of CTDl{sub vol} indicating a high potential for dose reduction. This result requires immediate action for optimization and implementation of diagnostic reference values in Latin America.