WorldWideScience

Sample records for tomography avaliacao da

  1. AIDS related thoracic lymphoma: evaluation by computed tomography; Linfoma toracico na sindrome da imunodeficiencia adquirida: avaliacao por tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Siciliano, Antonio Alexandre de Oliveira [Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil). Servico de Radiodiagnostico; Marchiori, Edson [Universidade Federal, Rio de Janeiro, RJ (Brazil). Curso de Pos-graduacao em Radiologia

    2000-02-01

    The authors reviewed five cases of patients with acquired immunodeficiency syndrome (AIDS) related lymphoma to describe the thoracic findings on computed tomography. The patients were followed at Hospital Universitario Clementino Fraga Filho, Hospital Universitario Antonio Pedro and Hospital da Lagoa, from November, 1989 to March 1998. Epidemiological, clinical and pathological data from these patients were quiet variable and pulmonary nodules and masses, hilar and mediastinal lymphadenopathy, and thoracic wall masses were observed. AIDS related lymphomas involving the chest are pleomorphic and most commonly extranodal. (author)

  2. Evaluation of the absorbed dose in odontological computerized tomography; Avaliacao da dose absorvida em tomografia computadorizada odontologica

    Energy Technology Data Exchange (ETDEWEB)

    Legnani, Adriano; Schelin, Hugo R; Rocha, Anna Silvia P.S. da, E-mail: schelin@utfpr.edu.b, E-mail: anna@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Khoury, Helen J., E-mail: khoury@ufpe.b [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2011-10-26

    This paper evaluated the absorbed dose at the surface entry known as 'cone beam computed tomography' (CBCT) in odontological computerized tomography. Examination were simulated with CBCT for measurements of dose. A phantom were filled with water, becoming scatter object of radiation. Thermoluminescent dosemeters were positioned on points correspondent to eyes and salivary glands

  3. Evaluation of the absorbed dose in odontological computerized tomography; Avaliacao da dose absorvida em tomografia computadorizada odontologica

    Energy Technology Data Exchange (ETDEWEB)

    Legnani, Adriano; Schelin, Hugo R.; Rocha, Anna Silvia P.S. da, E-mail: schelin@utfpr.edu.b, E-mail: anna@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Khoury, Helen J., E-mail: khoury@ufpe.b [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2011-10-26

    This paper evaluated the absorbed dose at the surface entry known as 'cone beam computed tomography' (CBCT) in odontological computerized tomography. Examination were simulated with CBCT for measurements of dose. A phantom were filled with water, becoming scatter object of radiation. Thermoluminescent dosemeters were positioned on points correspondent to eyes and salivary glands

  4. Avaliação da reprodutibilidade da tomografia computadorizada no estadiamento da pancreatite aguda Reproducibility in the assessment of acute pancreatitis with computed tomography

    Directory of Open Access Journals (Sweden)

    Edison de Oliveira Freire Filho

    2007-12-01

    Full Text Available OBJETIVO: Medir a reprodutibilidade da tomografia computadorizada sem e com contraste na avaliação da gravidade da pancreatite aguda. MATERIAIS E MÉTODOS: Cinqüenta e um exames de tomografia computadorizada abdominal sem e com contraste de pacientes com pancreatite aguda foram analisados por dois radiologistas (observadores 1 e 2. Calculamos o índice morfológico pela tomografia computadorizada sem e com contraste, separadamente, e o índice de gravidade da tomografia computadorizada para pancreatite aguda. Medimos a reprodutibilidade intra- e interobservador da tomografia computadorizada através do índice kappa (kapa. RESULTADOS: Para a concordância interobservador obtivemos kapa de 0,666, 0,705, 0,648, 0,547 e 0,631 para índice morfológico sem e com contraste, presença de necrose pancreática, extensão da necrose pancreática e índice de gravidade da tomografia computadorizada, respectivamente. Para a concordância intra-observador dos observadores 1 e 2 obtivemos, respectivamente, kapa de 0,796 e 0,732 para o índice morfológico sem contraste; 0,725 e 0,802 para o índice morfológico com contraste; 0,674 e 0,849 para a presença de necrose pancreática; 0,606 e 0,770 para a extensão da necrose pancreática; e 0,801 e 0,687 para o índice de gravidade da tomografia computadorizada. CONCLUSÃO: O estadiamento da pancreatite aguda pela tomografia computadorizada por meio do índice morfológico e do índice de gravidade da tomografia computadorizada é um método bastante reprodutível. O não-uso do contraste não afeta a reprodutibilidade da tomografia computadorizada para o cálculo do índice morfológico.OBJECTIVE: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. MATERIALS AND METHODS: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two

  5. Density evaluation by computerized tomography in plain soils over different manipulation systems; Avaliacao da densidade pelo metodo da tomografia computadorizada de um planossolo sob diferentes sistemas de manejo

    Energy Technology Data Exchange (ETDEWEB)

    Pedrotti, Alceu [Lavras Univ., MG (Brazil). Dept. de Ciencia do Solo; Pauletto, Eloy Antonio [Pelotas Univ., RS (Brazil). Dept. de Solos; Crestana, Silvio [Empresa Brasileira de Pesquisa Agropecuaria (EMBRAPA), Sao Carlos, SP (Brazil). Centro Nacional de Pesquisa e Desenvolvimento de Instrumentacao Agropecuaria (CNPDIA)

    1996-08-01

    The objective of this paper is the evaluation of a plain soil density in different culture systems determined by X ray computerized tomography.It was observed a larger variation in densities in soils profiles analysed. The identification of layers is better utilising computerized tomography than others technic 1 fig.

  6. Avaliacao de projeto de promocao da saude para adolescentes

    Directory of Open Access Journals (Sweden)

    Jovino Oliveira Ferreira

    2013-06-01

    Full Text Available OBJETIVO: Avaliar programa de promoção de atividade física e de escolhas alimentares entre adolescentes. MÉTODOS: Estudo transversal realizado com 911 adolescentes de 13 a 18 anos de idade, de escolas públicas de Goiânia, GO, em 2010. Os participantes foram divididos em dois grupos: intervenção (escolas participantes do Projeto Viver Saudável e controle. Foram considerados como atividade física: deslocamento, aulas de educação física na escola, atividade física fora da escola e no lazer. Foram definidos como ativos aqueles que acumularam 300 ou mais minutos por semana. Quanto às escolhas alimentares, foi classificado como adequado o consumo de alimentos protetores em cinco ou mais dias da semana. Foram realizadas análises estatísticas com teste de Qui-quadrado de Pearson. RESULTADOS: A maioria dos adolescentes foi identificada como inativos ou insuficientemente ativos, com 65,7% no grupo intervenção e 65,2% no grupo controle, sem diferenças significativas entre os grupos e com prevalência maior entre o sexo feminino. Pouco mais da metade dos adolescentes consumiam alimentos protetores da saúde em cinco ou mais dias da semana, sendo 56,6% e 50,4%, respectivamente, nos grupos intervenção e controle (p = 0,373. CONCLUSÕES: A ausência de diferenças quanto a escolhas alimentares e prática de atividade física entre os grupos intervenção e controle indica que o projeto Viver Saudável precisa ser reavaliado visando melhorar a efetividade no cumprimento dos seus objetivos.

  7. Instrumentos em Lingua Brasileira de Sinais para avaliacao da qualidade de vida da populacao surda

    Directory of Open Access Journals (Sweden)

    Neuma Chaveiro

    2013-06-01

    Full Text Available OBJETIVO: Construir a versão em Língua Brasileira de Sinais dos instrumentos WHOQOL-BREF e WHOQOL-DIS para avaliar a qualidade de vida da população surda brasileira. MÉTODOS: Utilizou-se metodologia proposta pela Organização Mundial da Saúde (WHOQOL-BREF e WHOQOL-DIS para a construção dos instrumentos adaptados para população surda em Língua Brasileira de Sinais (Libras. A pesquisa para execução do instrumento consistiu de 13 etapas: 1 criação do sinal qualidade de vida; 2 desenvolvimento das escalas de respostas em Libras; 3 tradução por um grupo bilíngue; 4 versão reconciliadora; 5 primeira retrotradução; 6 produção da versão em Libras a ser disponibilizada aos grupos focais; 7 realização dos grupos focais; 8 revisão por um grupo monolíngue; 9 revisão pelo grupo bilíngue; 10 análise sintática/semântica e segunda retrotradução; 11 reavaliação da retrotradução pelo grupo bilíngue; 12 filmagem da versão para o software; 13 desenvolvimento do software WHOQOL-BREF e WHOQOL-DIS em Libras. RESULTADOS: Características peculiares da cultura da população surda apontaram a necessidade de adaptações na metodologia de aplicação de grupos focais quando compostos por pessoas surdas. As convenções ortográficas da escrita das línguas sinalizadas não estão consolidadas, o que trouxe dificuldades em registrar graficamente as etapas de tradução. As estruturas linguísticas que causaram maiores problemas de tradução foram as que incluíram expressões idiomáticas do português, muitas sem conceitos equivalentes entre o português e a Libras. Foi possível construir um software do WHOQOL-BREF e WHOQOL-DIS em Libras. CONCLUSÕES: O WHOQOL-BREF e o WHOQOL-DIS em Libras possibilitarão que os surdos se expressem autonomamente quanto a sua qualidade de vida, o que permitirá investigar com maior precisão essas questões.

  8. Stratus optical coherence tomography findings in patients with retinopathy of prematurity Tomografia de coerência óptica em pacientes com retinopatia da prematuridade

    Directory of Open Access Journals (Sweden)

    Aline do Lago

    2007-02-01

    Full Text Available PURPOSE: To describe morphological features of the macula in patients with retinopathy of prematurity. METHODS: Twelve premature babies with retinopathy of prematurity grades I, II and III underwent dilated fundus examination and optical coherence tomography evaluation. RESULTS: In all thirteen eyes of the twelve premature patients optical coherence tomography revealed a condensed retinal pigmented epithelial layer in the macular-foveal area shown by increased reflectivity. In these eyes the retinal layers were not well differentiated. Foveal depression was clearly evident in 23%. CONCLUSIONS: In premature patients with retinopathy of prematurity, optical coherence tomography revealed poorly differentiated layers in the macular region with increased reflectivity in retinal pigmented epithelial-choriocapillaris zone.OBJETIVO: Descrever os aspectos morfológicos da mácula em pacientes com retinopatia da prematuridade (ROP. MÉTODOS: Doze pacientes com retinopatia da prematuridade graus I, II and III foram submetidos a mapeamento de retina e avaliação por tomografia de coerência óptica. RESULTADOS: Em todos os treze olhos de 12 pacientes a tomografia de coerência óptica mostrou a camada do epitélio pigmentar hiperrefletiva, sendo a área macular com maior intensidade. Nesses olhos as camadas da retina não estavam totalmente diferenciadas. A depressão foveal ficou claramente evidente pela tomografia de coerência óptica em 23%. CONCLUSÃO: Nos pacientes prematuros com retinopatia da prematuridade, a tomografia de coerência óptica mostrou as camadas da retina pouco diferenciadas com aumento da refletividade na área macular do complexo epitélio retiniano pigmentar-coriocapilar.

  9. Avaliacao de interacoes medicamentosas potenciais em prescricoes da atencao primaria de Vitoria da Conquista (BA), Brasil

    OpenAIRE

    Danyllo Fabio Lessa Leao; Cristiano Soares de Moura; Danielle Souto de Medeiros

    2014-01-01

    As interações medicamentosas são fatores de risco para a ocorrência de reações adversas a medicamentos. Este estudo teve o objetivo de avaliar as interações medicamentosas potenciais em prescrições da atenção primária de Vitória da Conquista (BA), visando preencher a lacuna de conhecimento sobre essa temática no Brasil. Foram coletadas informações sobre diversas variáveis de prescrições oriundas da atenção primária e as interações medicamentosas avaliadas a partir dos bancos de dados do Medsc...

  10. Avaliacao de interacoes medicamentosas potenciais em prescricoes da atencao primaria de Vitoria da Conquista (BA, Brasil

    Directory of Open Access Journals (Sweden)

    Danyllo Fabio Lessa Leao

    2014-01-01

    Full Text Available As interações medicamentosas são fatores de risco para a ocorrência de reações adversas a medicamentos. Este estudo teve o objetivo de avaliar as interações medicamentosas potenciais em prescrições da atenção primária de Vitória da Conquista (BA, visando preencher a lacuna de conhecimento sobre essa temática no Brasil. Foram coletadas informações sobre diversas variáveis de prescrições oriundas da atenção primária e as interações medicamentosas avaliadas a partir dos bancos de dados do Medscape e Micromedex(r. Verificou-se ainda a frequência de polifarmácia e associação desta com a ocorrência de interações medicamentosas. Os resultados mostraram frequência de 48,9% de interações medicamentosas, 74,9% delas de gravidade moderada ou maior, e 8,6% de prescrições em polifarmácia que, em teste qui-quadrado, mostrou associação positiva com ocorrência de interações medicamentosas potenciais (p < 0,001. As prescrições oriundas da atenção primária de Vitória da Conquista (BA apresentaram uma alta frequência de interações medicamentosas, porém faz-se necessária a análise de outros fatores de risco para ocorrência destas nesse nível de atenção à saúde.

  11. Estudo da síndrome de tração macular vítreo-retiniana idiopática por meio da tomografia de coerência óptica: relato de casos A study of idiophatic vitreomacular traction syndrome with optical coherence tomography images: cases report

    Directory of Open Access Journals (Sweden)

    Hélio Paulo Primiano Júnior

    2007-02-01

    Full Text Available OBJETIVOS: Avaliar alterações estruturais observadas na síndrome de tração macular vítreo-retiniana idiopática (STMI pela tomografia de coerência óptica (OCT, antes e depois da vitrectomia; identificar situações em que a tomografia de coerência óptica fornece informações adicionais da morfologia e patogênese desta doença. MÉTODOS: Imagens tomográficas (OCT Stratus comparativas da estrutura vítreo-retiniana foram realizadas em quatro pacientes, em estágios variados da síndrome de tração macular vítreo-retiniana idiopática. RESULTADOS: A tomografia de coerência óptica Stratus apresenta imagens vítreo-retinianas que auxiliam na conduta e tratamento da síndrome de tração macular vítreo-retiniana idiopatica. CONCLUSÃO: O exame da tomografia de coerência óptica permite boa visualização da arquitetura morfológica do vítreo e da retina na síndrome de tração macular vítreo-retiniana idiopática. Este exame nos auxilia na compreensão da patogênese, no planejamento do tratamento, clínico ou cirúrgico, e na avaliação pós-operatória das alterações estruturais retinianas.PURPOSE: To evaluate the features of idiophatic vitreomacular traction syndrome (VMT with ocular coherence tomography (OCT - Stratus, before and after vitrectomy; to identify situations where ocular coherence tomography provides additional information on disease morphology and pathogenesis. METHODS: Comparative retinal ocular coherence tomography imaging was performed in four patients with different stages of vitreomacular traction syndrome. RESULTS: Standard-resolution ocular coherence tomography Stratus provides vitreous-retinal images that help the management and treatment of vitreomacular traction syndrome. CONCLUSIONS: Standard-resolution ocular coherence tomography allows good visualization of the architectural morphology of the vitreous and retina in vitreomacular traction syndrome. It helps understanding its pathogenesis, planning

  12. Aspectos clínico-tomográficos da mucocele com invasão orbitária Clinical and computed tomography aspects of mucocele with orbital invasion

    Directory of Open Access Journals (Sweden)

    Mary Lúcia Bedran

    2003-08-01

    Full Text Available OBJETIVO: Avaliar e relacionar os achados clínico-radiológicos da mucocele orbitária. MÉTODOS: Análise clínica e de imagem referente a 166 pacientes com lesões expansivas da órbita examinadas com o tomógrafo Somaton DR da marca Siemens de terceira geração num período de 10 anos consecutivos em Hospital Universitário de referência. RESULTADOS: Os achados clínicos mais comuns foram tumoração e proptose do globo ocular. À tomografia computadorizada, o achado típico foi de massa com baixa densidade, originando-se em seios paranasais, com destruição óssea adjacente, invasão da órbita e deslocamento do globo ocular. CONCLUSÃO: O desenvolvimento da tomografia computadorizada foi decisivo no estudo da órbita pois propicia, por meio de exame radiológico altamente especializado, imagens de incrível fidelidade anatômica revelando informações sobre o processo patológico como sua localização, sua relação com as estruturas adjacentes e sua vascularização.PURPOSE: To analyze and establish clinical-radiological findings of orbital mucocele. METHODS: Clinical analysis and image of 166 patients with expansive orbital lesions submitted to third generation Siemens Somaton DR computed tomography from February 1986 to February 1995. RESULTS: The most common clinical findings were mass and proptosis. On computed tomography, the typical finding was mass with low density, coming from paranasal sinuses presenting adjacent bone destruction and orbital invasion, with displacement of ocular globe. CONCLUSION: The development of computed tomography was an important mark in orbital studies because it allows incredible anatomic imagings, yielding information about the pathologic process like its localization and anatomic relation.

  13. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography; Avaliacao dos diametros normais da aorta toracica e abdominal pela tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, Claudio Luiz

    1995-07-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  14. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography; Avaliacao dos diametros normais da aorta toracica e abdominal pela tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, Claudio Luiz

    1995-07-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  15. Quantitative computed tomography as a test of endurance for evaluation of bony plates; Utilizacao da tomografia computadorizada quantitativa como teste de resistencia para avaliacao de placas osseas

    Energy Technology Data Exchange (ETDEWEB)

    Melo Filho, E.V.; Costa, L.A.V.S.; Oliveira, D.C. [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil); Freitas, P.M.C. [Escola de Veterinaria - Universidade Federal de Minas Gerais - Belo Horizonte, MG (Brazil); Teixeira, M.W.; Costa, F.S. [Universidade Federal Rural de Pernambuco - Recife, PE (Brazil)

    2012-06-15

    Quantitative computed tomography was used to determine the radiodensity of bony plates. The CT scans provided information regarding radiodensity of bony plates and allowed to verify the uniformity of bone mineral density in their scope. The proposed methodology should be considered as another tool for determining the resistance of these biomaterials. (author)

  16. Life-cycle optimization model for distributed generation in buildings

    Science.gov (United States)

    Safaei, Amir

    O setor da construcao e responsavel por uma grande parte do consumo de energia e emissoes na Uniao Europeia. A Geracao Distribuida (GD) de energia, nomeadamente atraves de sistemas de cogeracao e tecnologias solares, representa um papel importante no futuro energetico deste setor. A otimizacao do funcionamento dos sistemas de cogeracao e uma tarefa complexa, devido as diversas variaveis em jogo, designadamente: os diferentes tipos de necessidades energeticas (eletricidade, aquecimento e arrefecimento), os precos dinamicos dos combustiveis (gas natural) e da eletricidade, e os custos fixos e variaveis dos diferentes sistemas de GD. Tal torna-se mais complexo considerando a natureza flutuante das tecnologias solares termicas e fotovoltaicas. Ao mesmo tempo, a liberalizacao do mercado da eletricidade permite exportar para a rede, a electricidade gerada localmente. Adicionalmente, a operacao estrategica de um sistema de GD deve atender aos quadros politicos nacionais, se tiver como objetivo beneficiar de tais regimes. Alem disso, considerando os elevados impactes ambientais do setor da construcao, qualquer avaliacao energetica de edificios rigorosa deve tambem integrar aspetos ambientais, utilizando uma abordagem de Ciclo de Vida (CV). Uma avaliacao de Ciclo de Vida (ACV) completa de um sistema de GD deve incluir as fases relativas a operacao e construcao do sistema, bem como os impactes associados a producao dos combustiveis. Foram analisadas as emissoes da producao de GN, as quais variam de acordo com a origem, tipo (convencional ou nao-convencional), e estado (na forma de GN Liquefeito (GNL) ou gas). Do mesmo modo, o impacte dos sistemas solares e afetado pela meteorologia e radiacao solar, de acordo com a sua localizacao geografica. Sendo assim, uma avaliacao adequada dos sistemas de GD exige um modelo de ACV adequado a localizacao geografica (Portugal), integrando tambem a producao de combustivel (GN), tendo em conta as suas diferentes fontes de abastecimento. O

  17. Hunting for the Tristan mantle plume - An upper mantle tomography around the volcanic island of Tristan da Cunha

    Science.gov (United States)

    Schlömer, Antje; Geissler, Wolfram H.; Jokat, Wilfried; Jegen, Marion

    2017-03-01

    The active volcanic island Tristan da Cunha, located at the southwestern and youngest end of the Walvis Ridge - Tristan/Gough hotspot track, is believed to be the surface expression of a huge thermal mantle anomaly. While several criteria for the diagnosis of a classical hotspot track are met, the Tristan region also shows some peculiarities. Consequently, it is vigorously debated if the active volcanism in this region is the expression of a deep mantle plume, or if it is caused by shallow plate tectonics and the interaction with the nearby Mid-Atlantic Ridge. Because of a lack of geophysical data in the study area, no model or assumption has been completely confirmed. We present the first amphibian P-wave finite-frequency travel time tomography of the Tristan da Cunha region, based on cross-correlated travel time residuals of teleseismic earthquakes recorded by 24 ocean-bottom seismometers. The data can be used to image a low velocity structure southwest of the island. The feature is cylindrical with a radius of ∼100 km down to a depth of 250 km. We relate this structure to the origin of Tristan da Cunha and name it the Tristan conduit. Below 250 km the low velocity structure ramifies into narrow veins, each with a radius of ∼50 km. Furthermore, we imaged a linkage between young seamounts southeast of Tristan da Cunha and the Tristan conduit.

  18. Avaliação da concordância interobservador na análise da tomografia computadorizada sem contraste no diagnóstico da urolitíase em pacientes com cólica renal aguda Interobserver agreement on non-contrast computed tomography interpretation for diagnosis of urolithiasis in patients with acute flank pain

    Directory of Open Access Journals (Sweden)

    Luís Ronan Marquez Ferreira de Souza

    2006-10-01

    Full Text Available OBJETIVO: Avaliar a reprodutibilidade da tomografia computadorizada sem contraste na avaliação da litíase ureteral e os sinais secundários de obstrução do sistema coletor em pacientes com cólica renal aguda. MATERIAIS E MÉTODOS: Estudo prospectivo de 52 pacientes com diagnóstico clínico de cólica renal aguda submetidos a exame de tomografia computadorizada de abdome sem contraste. Os exames foram realizados com técnica helicoidal e posteriormente analisados por três observadores independentes, com a concordância interobservador avaliada pelo método estatístico kappa (kapa. Foram analisados os parâmetros: a presença, localização e mensuração dos cálculos ureterais; b dilatação do sistema coletor intra-renal; c heterogeneidade da gordura perirrenal; d dilatação ureteral; e edema da parede ureteral (sinal do halo. RESULTADOS: Foram encontrados 40 cálculos ureterais na tomografia computadorizada (77%. A concordância interobservador para a identificação do cálculo ureteral e da dilatação ureteral foi quase perfeita (kapa = 0,89 e kapa = 0,87, respectivamente, substancial para dilatação do sistema coletor intra-renal (kapa = 0,77 e moderada para heterogeneidade da gordura perirrenal e para edema da parede ureteral (kapa = 0,55 e kapa = 0,56, respectivamente. CONCLUSÃO: A tomografia computadorizada de abdome sem contraste apresenta elevada reprodutibilidade na avaliação da litíase ureteral e dos sinais secundários de obstrução do sistema coletor.OBJECTIVE: To evaluate the interobserver agreement on non-contrast computed tomography interpretation by a group of experienced abdominal radiologists, for the study of urolithiasis in patients presenting acute flank pain. MATERIALS AND METHODS: Prospective study of 52 patients submitted to non-contrast enhanced helical computed tomography. The images were subsequently analyzed by three independent observers, with the interobserver agreement assessed by means of the

  19. Computed tomography evaluation of mast cell tumours; Avaliacao por tomografia computadorizada dos mastocitomas

    Energy Technology Data Exchange (ETDEWEB)

    Lorigados, Carla Aparecida Batista; Matera, Julia Maria; Macedo, Thais; Pinto, Ana Carolina Brandao Fonseca, E-mail: clorigados@usp.br [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Cirurgia

    2012-07-01

    The mast cell tumours are common tumours of the canine skin. Computed tomography (CT) has assumed an important role in tumours evaluation and staging. The aim of this study was to evaluate the role of CT as a method of assessing characteristics of mast cell tumors. Ten dogs with mast cell tumor were evaluated. CT was performed before and after the intravenous injection of hydro soluble ionic iodine. Attenuation, contrast enhancement, cleavage with adjacent tissues and the unidimensional measurement of each lesion was determined in it maximum diameter, in transversal plane. Concerning the attenuation characteristic, 50% were homogeneous and 50% heterogeneous. The contrast enhancement was homogeneous in 50% of cases, heterogeneous in 40% and peripheral in 10%. Fifty percent of the tumours showed loss of plane of cleavage and 30% partial loss. This information can help in directing the patients that will be undergoing chemotherapy or surgery. (author)

  20. Avaliação da expansão rápida da maxila por meio da tomografia computadorizada: relato de um caso Computed tomography evaluation of rapid maxillary expansion: a case report

    Directory of Open Access Journals (Sweden)

    Daniela Gamba Garib

    2005-08-01

    Full Text Available Este trabalho descreve os efeitos dentoesqueléticos e periodontais da expansão rápida da maxila (ERM, avaliados por meio da tomografia computadorizada (TC, em uma jovem de 11,6 anos de idade com má oclusão de Classe I e mordida cruzada posterior unilateral funcional. Durante a fase ativa da ERM, o expansor dentossuportado com parafuso Hyrax foi ativado 7mm. A paciente submeteu-se ao exame de TC helicoidal, antes da expansão e após a remoção do aparelho expansor, findo o período de três meses de contenção. Realizaram-se cortes axiais, de um milímetro de espessura, paralelamente ao plano palatino, englobando as regiões dentoalveolar e basal da maxila, até o terço inferior da cavidade nasal. Utilizando-se o recurso de reconstruções multiplanares, mensuraram-se pelo método computadorizado: as dimensões transversas maxilares, a inclinação dos dentes posteriores, a espessura das tábuas ósseas vestibular e lingual, e o nível da crista óssea alveolar vestibular. A expansão rápida da maaxila ocasionou um significante aumento transverso em todas as regiões aferidas, com magnitude decrescente do arco dentário para a base óssea. Os dentes posteriores foram movimentados para vestibular, com um componente de inclinação e translação associados. Tal efeito ortodôntico ocasionou uma redução na espessura da tábua óssea vestibular, e um concomitante aumento na espessura da tábua óssea lingual. Após a expansão, observou-se o desenvolvimento de deiscências ósseas por vestibular dos dentes de ancoragem.This paper presents a computed tomography (CT evaluation of rapid maxillary expansion dentoskeletal and periodontal effects, in a 11.6 year-old girl presenting Class I malocclusion with posterior unilateral crossbite. The tooth-borne expander with Hyrax screw was activated 7-mm. The patient was submitted to helicoidal CT scan before expansion and after the three-month retention period when the expander was removed. Axial

  1. Tomografia computadorizada no diagnóstico da otosclerose retrofenestral Computed tomography in the diagnosis of retrofenestral otosclerosis

    Directory of Open Access Journals (Sweden)

    Andy de Oliveira Vicente

    2004-01-01

    Full Text Available OBJETIVO: Identificar os principais achados tomográficos da otosclerose retrofenestral. MÉTODO: Estudo prospectivo multicêntrico com tomografia computadorizada (TC de ossos temporais em 54 pacientes com diagnóstico clínico e cirúrgico de otosclerose. Foi realizada uma análise tomográfica, em que foi avaliada a utilidade da TC no diagnóstico radiológico da otosclerose retrofenestral, sendo verificados os principais sítios de lesões dessa doença. Foram incluídos neste estudo 22 pacientes submetidos à TC de ossos temporais para investigação de outras afecções otológicas, que constituíram o grupo controle. RESULTADOS: Os achados tomográficos foram bilaterais na maioria dos casos e o foco retrofenestral mais prevalente foi o foco pericoclear. CONCLUSÕES: A TC monstrou-se útil na identificação dos focos retrofenestrais. A evidência tomográfica desses focos juntamente com o envolvimento endosteal da cóclea podem sugerir uma maior atividade da doença.AIM: To identify the main tomographic findings of retrofenestral otosclerosis. METHODS: A prospective and multicentric study using computed tomography (CT of the temporal bone in 54 patients with a clinical and surgical diagnosis of otosclerosis. A tomographic analysis has been performed to evaluate the utility of CT scans in diagnosing retrofenestral otosclerosis, verifying the sites of predilection for otosclerotic lesions. In this study, 22 patients undergone CT scans of temporal bones have been included in order to investigate other otologic diseases and have constituted the control group. RESULTS: The tomographic findings were mostly bilateral and the retrofenestral focus more prevalent was the pericochlear focus. CONCLUSIONS: The CT scan was useful in the identification of the retrofenestral focuses. The evidence of this focuses and the presence of the endosteal involvement of the cochlea can suggest a higher activity of the disease.

  2. Avaliacao da Relacao entre a Doenca Hepatica Nao Gordurosa e CAD utilizando TCMF

    Directory of Open Access Journals (Sweden)

    Duran Efe

    2014-01-01

    Full Text Available Fundamento: Alguns fatores de risco para a aterosclerose são acompanhados pela doença hepática gordurosa não alcoólica (DHGNA. Desejamos usar a tomografia computadorizada multi-fatias (TCMF como a técnica para encontrar relação entre a DHGNA e a doença arterial coronariana (DAC. Objetivo: A relação entre a DHGNA e a DAC foi investigada através de TCMF. Métodos: Um total de 372 indivíduos com ou sem sintomas cardíacos, que foram submetidos à angiografia por TCMF, foram incluídos no estudo. Os pacientes foram divididos em dois grupos, de acordo com a presença da DHGNA. Os segmentos arteriais coronarianos foram avaliados visualmente via angiografia por TCMF. Com base no grau de estenose arterial coronariana, aqueles com placas ausentes ou mínimas foram considerados como normais, enquanto aqueles que apresentavam estenose de menos do que 50% e no mínimo uma placa foram considerados como portadores da doença arterial coronariana não obstrutiva (não-obsDAC. Os pacientes que apresentaram no mínimo uma placa e estenose arterial coronariana de 50% ou mais foram considerados como portadores de doença arterial coronariana obstrutiva (obsDAC. A DHGNA foi determinada de acordo com o protocolo de TCMF, utilizando a densidade hepática. Resultados: De acordo com a densidade hepática, o número de pacientes com doença hepática gordurosa não alcoólica (grupo 1 foi de 204 (149 homens, 54,8% e com fígado normal (grupos 2 foi de 168 (95 homens, 45.2%. Houve 50 (24,5% não-obsDAC e 57 (27,9% casos de obsDAC no Grupo 1, e 39 (23,2% não-obsDAC e 23 (13,7% casos de obsDAC no Grupo 2. Conclusões: O presente estudo utilizando TCMF demonstrou que a frequência da doença arterial coronariana em pacientes com NAFDL foi significativamente superior do que nos pacientes em NAFDL.

  3. Biaxial seismic behaviour of reinforced concrete columns =

    Science.gov (United States)

    Rodrigues, Hugo Filipe Pinheiro

    A analise dos efeitos dos sismos mostra que a investigacao em engenharia sismica deve dar especial atencao a avaliacao da vulnerabilidade das construcoes existentes, frequentemente desprovidas de adequada resistencia sismica tal como acontece em edificios de betao armado (BA) de muitas cidades em paises do sul da Europa, entre os quais Portugal. Sendo os pilares elementos estruturais fundamentais na resistencia sismica dos edificios, deve ser dada especial atencao a sua resposta sob acoes ciclicas. Acresce que o sismo e um tipo de acao cujos efeitos nos edificios exige a consideracao de duas componentes horizontais, o que tem exigencias mais severas nos pilares comparativamente a acao unidirecional. Assim, esta tese centra-se na avaliacao da resposta estrutural de pilares de betao armado sujeitos a acoes ciclicas horizontais biaxiais, em tres linhas principais. Em primeiro lugar desenvolveu-se uma campanha de ensaios para o estudo do comportamento ciclico uniaxial e biaxial de pilares de betao armado com esforco axial constante. Para tal foram construidas quatro series de pilares retangulares de betao armado (24 no total) com diferentes caracteristicas geometricas e quantidades de armadura longitudinal, tendo os pilares sido ensaiados para diferentes historias de carga. Os resultados experimentais obtidos sao analisados e discutidos dando particular atencao a evolucao do dano, a degradacao de rigidez e resistencia com o aumento das exigencias de deformacao, a energia dissipada, ao amortecimento viscoso equivalente; por fim e proposto um indice de dano para pilares solicitados biaxialmente. De seguida foram aplicadas diferentes estrategias de modelacao nao-linear para a representacao do comportamento biaxial dos pilares ensaiados, considerando nao-linearidade distribuida ao longo dos elementos ou concentrada nas extremidades dos mesmos. Os resultados obtidos com as varias estrategias de modelacao demonstraram representar adequadamente a resposta em termos das curvas

  4. Unilateral pulmonary veins atresia: evaluation by computed tomography; Atresia unilateral das veias pulmonares: avaliacao por tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Eifer, Diego Andre; Arsego, Felipe Veras, E-mail: felipesoarestorres@gmail.com [Hospital de Clinicas de Porto Alegre (HCPA), RS (Brazil). Serv. de Radiologia; Torres, Felipe Soares [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Escola de Medicina

    2013-11-15

    Unilateral pulmonary vein atresia is a rare congenital condition. In addition to cardiac malformations or pulmonary hypertension, patients may present with recurrent pulmonary infections or hemoptysis in childhood or adolescence. The authors report a case where the typical findings of such condition were observed at computed tomography in an adult patient. (author)

  5. O valor da fase sem contraste na tomografia computadorizada do abdome The role of the unenhanced phase in the routine abdominal computed tomography

    Directory of Open Access Journals (Sweden)

    Ana Paula Klautau Leite

    2008-10-01

    Full Text Available OBJETIVO: Determinar o valor agregado da fase sem meio de contraste da tomografia computadorizada do abdome em pacientes sem diagnóstico determinado ou em estadiamento tumoral. MATERIAIS E MÉTODOS: Estudo prospectivo e transversal em 100 pacientes consecutivos submetidos a tomografia computadorizada abdominal sem e com meio de contraste intravenoso. Dois examinadores avaliaram todos os exames, procurando estabelecer, através da fase com meio de contraste intravenoso (primeira análise e posteriormente através da fase sem contraste (segunda análise, o diagnóstico principal e os secundários em função da indicação clínica do exame. Mediu-se a freqüência de mudança diagnóstica decorrente da análise combinada das fases pré- e pós-contraste intravenoso. Casos que tiveram mudança diagnóstica foram avaliados por especialistas clínicos para determinar se implicaria mudanças de conduta. RESULTADOS: Diagnósticos principal e secundário foram modificados em 1 e 18 casos, respectivamente (p = 1,000; p = 0,143. Os diagnósticos modificados foram: esteatose, definição de nódulo em adrenal, nefrolitíase, classificação de cistos renais e calcificação hepática. Nos casos em que a fase sem contraste modificou o diagnóstico, os especialistas mudaram sua conduta em 14/19 (73% dos pacientes (p = 0,038. CONCLUSÃO: A fase sem contraste não modificou significativamente o diagnóstico principal ou secundário. Porém, as mudanças nos diagnósticos secundários influenciaram na conduta adotada pelos especialistas.OBJECTIVE: To determine the role of the unenhanced phase of abdominal computed tomography in patients without a definite diagnosis or undergoing tumor staging. MATERIALS AND METHODS: A prospective and transversal study was developed with 100 consecutive patients submitted to unenhanced and contrast-enhanced abdominal computed tomography. Two observers evaluated all the computed tomography images in the contrast-enhanced phase

  6. Three-dimensional evaluation of human jaw bone microarchitecture: correlation between the microarchitectural parameters of cone beam computed tomography and micro-computer tomography.

    Science.gov (United States)

    Kim, Jo-Eun; Yi, Won-Jin; Heo, Min-Suk; Lee, Sam-Sun; Choi, Soon-Chul; Huh, Kyung-Hoe

    2015-12-01

    To evaluate the potential feasibility of cone beam computed tomography (CBCT) in the assessment of trabecular bone microarchitecture. Sixty-eight specimens from four pairs of human jaw were scanned using both micro-computed tomography (micro-CT) of 19.37-μm voxel size and CBCT of 100-μm voxel size. The correlation of 3-dimensional parameters between CBCT and micro-CT was evaluated. All parameters, except bone-specific surface and trabecular thickness, showed linear correlations between the 2 imaging modalities (P < .05). Among the parameters, bone volume, percent bone volume, trabecular separation, and degree of anisotropy (DA) of CBCT images showed strong correlations with those of micro-CT images. DA showed the strongest correlation (r = 0.693). Most microarchitectural parameters from CBCT were correlated with those from micro-CT. Some microarchitectural parameters, especially DA, could be used as strong predictors of bone quality in the human jaw. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Leitura rapida do KDIGO 2012: Diretrizes para avaliacao e manuseio da doenca renal cronica na pratica clinica

    Directory of Open Access Journals (Sweden)

    Gianna Mastroianni Kirsztajn

    2014-03-01

    Full Text Available Os autores desta "leitura rápida" apresentam os dados que consideraram mais relevantes na versão 2012 do KDIGO referente à avaliação e manuseio da doença renal crônica. Não se trata da opinião dos autores, mas sim de uma apresentação mais concisa das diretrizes, que podem ser úteis na prática clínica.

  8. Assessment in dogs tympanic bulla, through virtual tomographic endoscopy; Avaliacao de bulas timpanicas em caes, por meio da endoscopia tomografica virtual

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Luciana Carandina da; Sabino, Emanuelle Guidugli, E-mail: lucianacarandina@uol.com.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria. Dept. de Reproducao Animal e Radiologia Veterinaria; Vulcano, Luiz Carlos; Machado, Vania Maria de Vasconcelos [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria

    2012-07-01

    Dogs usually have problems related to the auditory canal. For the diagnosis of these pathologies, it is necessary a physical examination and, in some cases radiographic examination and computed tomography. The tympanic bulla is not easily visualized radiographically, since there is many structures of the brain overlaying the image obtained. The computed tomography has been the technique of choice to assess this structure faithfully. A new alternative assessment of the tympanic bulla is tomographic virtual endoscopy, which allows an improvement of the image obtained through the virtual tomographic technique. This paper provides information on the use of computed tomography, and a new technique, tomographic virtual endoscopy, in order to make the improvement of these techniques, and prove the reliability of these changes in the diagnosis of ear canals of dogs. Therefore, we performed the computed tomography of the tympanic bulla on healthy animals, and later performed image reconstruction in three-dimensional (3D) mode for virtual endoscopy. (author)

  9. Computerized tomography findings in Fahr's syndrome Achados da tomografia computadorizada na síndrome de Fahr

    Directory of Open Access Journals (Sweden)

    Andréia V. Faria

    2004-09-01

    Full Text Available We analyzed computerized tomography (CT findings in six patients with Fahr's syndrome. They presented calcifications in basal ganglia, dentate nucleus, subcortical region and semioval center, due to alteration in calcium metabolism or due to senile relative hypoxemic state. The image pattern was not strictly related with etiology, although some differences in dystrophic senile calcifications (the only one present in semioval center and absent in subcortical region. CT is an easy exam, has maximum sensitivity and allows diagnosis, contributing to early treatment of many etiologies of Fahr's syndrome.Analisamos os achados de tomografia computadorizada (TC de seis pacientes com síndrome de Fahr. Eles apresentaram calcificações nos gânglios da base, núcleo denteado, região subcortical e centro semi-oval, devidas a distúrbios no metabolismo do cálcio ou a estado de hipóxia relativa, por senilidade. O padrão de imagem não apresenta relação clara com a etiologia, apesar de algumas diferenças no caso das calcificações distróficas senis (as únicas presentes nos centros semi-ovais e ausentes na região subcortical. TC é um exame de fácil realização, máxima sensibilidade e permite o diagnóstico, contribuindo para o tratamento precoce de muitas das etiologias da síndrome de Fahr.

  10. Proposta para padronização do relatório de tomografia computadorizada nos aneurismas da aorta abdominal A proposal for standardizing computed tomography reports on abdominal aortic aneurysms

    Directory of Open Access Journals (Sweden)

    Fabiola Goda Torlai

    2006-08-01

    Full Text Available OBJETIVO: Propor um modelo de padronização de relatório para aneurisma da aorta abdominal na tomografia computadorizada. MATERIAIS E MÉTODOS: Foram realizadas, no período de abril a outubro de 2004, entrevistas com integrantes da Disciplina de Cirurgia Vascular da nossa instituição, para elaboração de um modelo de padronização de relatório de tomografia computadorizada para o estudo do aneurisma da aorta abdominal. A partir deste modelo foi elaborado um questionário, enviado a nove outros cirurgiões, todos com experiência em cirurgia da aorta abdominal. O índice de resposta aos questionários foi de 55,5% (5/9. RESULTADOS: Os parâmetros de interesse citados mais freqüentemente para a avaliação dos aneurismas de aorta abdominal foram: diâmetro máximo do colo proximal, extensão do colo proximal até a artéria renal mais baixa, forma do colo proximal, diâmetro máximo do aneurisma e diâmetro das artérias ilíacas comuns. Estes dados permitiram elaborar uma proposta de modelo para padronização de relatório na tomografia computadorizada. CONCLUSÃO: Um modelo para a análise tomográfica padronizada do aneurisma de aorta abdominal permite atender às necessidades dos cirurgiões vasculares para acompanhar a evolução e planejar o tratamento destes pacientes.OBJECTIVE: To propose a model to standardize computed tomography reports on abdominal aortic aneurysms. MATERIALS AND METHODS: Interviews were carried out with members of Vascular Surgery Division of our institution, in the period between April and October 2004, aiming at developing a standardized model of computed tomography reports on abdominal aortic aneurysms. Based on this model, a questionnaire was elaborated and sent to other nine surgeons, all of them experienced in the field of abdominal aortic surgery. The questionnaires response rate was 55.5% (5/9. RESULTS: The most frequently mentioned parameters of interest for evaluation of abdominal aortic aneurysms

  11. Using Optical Coherence Tomography to Reveal the Hidden History of The Landsdowne Virgin of the Yarnwinder by Leonardo da Vinci and Studio.

    Science.gov (United States)

    Targowski, Piotr; Iwanicka, Magdalena; Sylwestrzak, Marcin; Frosinini, Cecilia; Striova, Jana; Fontana, Raffaella

    2018-03-07

    Optical coherence tomography (OCT) was used for non-invasive examination of a well-known, yet complex, painting from the studio of Leonardo da Vinci in combination with routine imaging in various bands of electromagnetic radiation. In contrast with these techniques, OCT provides depth-resolved information. Three post-processing modalities were explored: cross-sectional views, maps of scattering from given depths, and their 3D models. Some hidden alterations of the painting owing to past restorations were traced: retouching and overpainting with their positioning within varnish layers as well as indications of a former transfer to canvas. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Radiolabelled molecules for imaging the translocator protein (18 kDa) using positron emission tomography

    International Nuclear Information System (INIS)

    Dolle, F.; Luus, C.; Reynolds, A.; Kassiou, M.

    2009-01-01

    The translocator protein (18 kDa) (TSPO), formerly known as the peripheral benzodiazepine receptor (PBR), was originally identified as an alternate binding site for the central benzodiazepine receptor (CBR) ligand, diazepam, in the periphery, but has now been distinguished as a novel site. The TSPO is ubiquitously expressed in peripheral tissues but only minimally in the healthy brain and increased levels of TSPO expression have been noted in neuro inflammatory conditions such as Alzheimer's disease, Parkinson's disease and stroke. This increase in TSPO expression has been reported to coincide with the process of micro-glial activation, whereby the brain's intrinsic immune system becomes active. Therefore, by using recently developed high affinity, selective TSPO ligands in conjunction with functional imaging modalities such as positron emission tomography (PET), it becomes possible to study the process of micro-glial activation in the living brain. A number of high affinity ligands, the majority of which are C, N-substituted acetamide derivatives, have been successfully radiolabelled and used in in vivo studies of the TSPO and the process of micro-glial activation. This review highlights recent achievements (up to December 2008) in the field of functional imaging of the TSPO as well as the radio-syntheses involved in such studies. (authors)

  13. Avaliacao da espessura medio-intimal em pacientes com doenca renal cronica nao dialitica: estudo prospectivo de 24 meses

    Directory of Open Access Journals (Sweden)

    Andrea Gaspar Marcos

    2014-03-01

    Full Text Available Introdução: O aumento da espessura média-intimal (EMI avaliada por ultrassom é um preditor de risco cardiovascular na população geral. Porém, em pacientes com doença renal crônica nos estágios iniciais, essa associação ainda não está bem estabelecida. Objetivo: Avaliar a associação EMI com a ocorrência de eventos cardiovasculares e mortalidade em pacientes nos estágios iniciais da doença renal crônica. Métodos: A análise post hoc de uma coorte de pacientes nos estágios 2-4 da DRC. Foram avaliados dados laboratoriais, ultrassom da artéria carótida e tomografia coronariana no início do estudo e a ocorrência de óbito, em seguimento por 24 meses. Resultados: Um total de 117 pacientes (57 ± 11 anos, 61% sexo masculino foram avaliados. A taxa de filtração glomerular foi 36 ± 17 mL/min, 96% dos pacientes eram hipertensos, 23% diabéticos e 27% obesos. Calcificação arterial coronariana esteve presente em 48% dos pacientes, sendo mais prevalente em pacientes nos estágios mais avançados da DRC (p = 0,02. EMI foi 0,6 mm (0,4-0,7 mm. Comparado aos pacientes com EMI < 0,6mm, aqueles com EMI ≥ 0,6 mm eram mais velhos (p = 0,001, apresentavam maior prevalência do sexo masculino (p = 0,001, menor taxa de filtração glomerular (p = 0,01 e maior proporção de pacientes com calcificação (p = 0,001. Não foi observada relação entre a espessura média-intimal e a ocorrência de evento cardiovascular e óbito. Conclusão: A espessura médio-intimal em pacientes DRC se associou à calcificação coronariana, mas não à ocorrência de eventos cardiovasculares e óbito, em um seguimento de 24 meses.

  14. Índices bióticos para avaliação da qualidade ambiental em trechos do rio Correntoso, Pantanal do Negro, Estado do Mato Grosso do Sul, Brasil = Biotic indexes for the evaluation of environmental quality in stretches of the Correntoso river, Pantanal do Negro, Mato Grosso do Sul State, Brazil

    Directory of Open Access Journals (Sweden)

    Fábio Henrique da Silva

    2011-07-01

    Full Text Available Este trabalho teve como objetivo pesquisar a estrutura da comunidade de insetos aquaticos, utilizando esta comunidade como indicadora da qualidade ambiental de um trecho do rio Correntoso, Pantanal do Negro, Mato Grosso do Sul, Brasil. Foram realizadas seis campanhas de coleta em diferentes periodos sazonais: vazante, seca e cheia. Os organismos foram coletados utilizando rede D com malha de 300 ƒÝm eesforco amostral de cinco lances de rede nas raizes dos bancos de macrofitas. Foram comparados tres ambientes (aberto, intermediario e fechado, por juncao dos dados obtidos de seis sitios de coleta. Foi analisada a riqueza, abundancia absoluta e relativa das familias de insetos amostrados e a avaliacao da qualidade da agua usando o indiceBMWP, indice BMWP-ASPT, indice IBF e indice de diversidade de Shannon-Wienner, com log2. Foram registradas 60 familias pertencentes a 12 ordens da Classe Insecta, totalizando 19.773 individuos coletados. Entre os indices aplicados, o indice BMWP foi o que melhor representou as condicoes do ambiente estudado.This work aimed to research the aquatic insect community structure using this community as a bioindicator of the environmental quality in a stretch of the Correntoso river, in Pantanal do Negro, Mato Grosso do Sul, Brazil. Six collections were taken in different seasonal periods; ebb, dry and wet. The organisms were collected using a 300 ƒÝm mesh D net sweeping five times through the roots of macrophyte banks at each sample. Three environments were compared (open, intermediary, closed by adding the information from six collection sites. Family richness, absolute and relative abundance ofinsect samples and an evaluation of water quality were analyzed by using the BMWP index, BMWP-ASPT index, IBF index and Shannon diversity index, with log2. A total of 60 families from 12 orders of Insecta Class were recorded, totaling 19,773 individuals. Among the indexes applied, the BMWP index was the one that best

  15. Radiological evaluation of the cranio vertebral junction; Avaliacao radiologica da transicao cranio-vertebral

    Energy Technology Data Exchange (ETDEWEB)

    Mello, Silvia Marcal Benicio de; Haetinger, Rainer Guilherme [Med Imagem - Beneficiencia Portuguesa de Sao Paulo, SP (Brazil). Setor de Cabeca e Pescoco]. E-mail: sbm@uol.com.br; Schettini, Marianna Cunha; Lima, Sergio Santos [Med Imagem - Beneficiencia Portuguesa de Sao Paulo, SP (Brazil); Mourao, Maria Lucia; Mendonca, Renato Adam [Med Imagem - Beneficiencia Portuguesa de Sao Paulo, SP (Brazil). Setor de Neuroradiologia

    2005-04-15

    The cranio vertebral junction (CVJ) comprises the occiput, atlas, their joints and ligaments. Besides conventional x-rays other imaging methods are need for the assessment of CVJ including high resolution computerized tomography (CT) and magnetic resonance imaging (MRI) which provide specific parameters such as field of view, slice thickness and incremental movement of the patient. A dynamic study is also important to assess the stability of the cranio vertebral junction and the effect upon the bulbomedullary junction. The aim of this study is to review the techniques used in the evaluation of the CVJ, the semiological parameters, and the most frequent disorders affecting this region. We review the literature and present conventional x-ray, CT and MRI images from the didactic file of the Radiology service 'Med Imagem - Beneficiencia Portuguesa de Sao Paulo, SP, Brazil, of cases with normal anatomy and the main congenital and acquired disorders of the CVJ. In daily practice, CVJ disorders are diagnoses using CT and MRI scans of the head and cervical spine. It is essential to be familiar with these conditions in order to preform specific tests which will allow a detailed study of the CVJ, thus providing the basis for the treatment, whenever indicated. (author)

  16. Dose assessment in pediatric computerized tomography; Avaliacao de doses em tomografia computadorizada pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Vilarinho, Luisa Maria Auredine Lima

    2004-07-01

    The objective of this work was the evaluation of radiation doses in paediatric computed tomography scans, considering the high doses usually involved and the absence of any previous evaluation in Brazil. Dose values were determined for skull and abdomen examinations, for different age ranges, by using the radiographic techniques routinely used in the clinical centers investigated. Measurements were done using pencil shape ionization chambers inserted in polymethylmethacrylate (PMMA) phantoms. These were compact phantoms of different diameters were specially designed and constructed for this work, which simulate different age ranges. Comparison of results with published values showed that doses were lower than the diagnostic reference levels established to adults exams by the European Commission. Nevertheless, doses in paediatric phantoms were higher than those obtained in adult phantoms. The paediatric dose values obtained in Hospitals A and B were lower than the reference level (DRL) adopted by SHIMPTON for different age ranges. In the range 0 - 0.5 year (neonatal), the values of DLP in Hospital B were 94 por cent superior to the DRL For the 10 years old children the values of CTDI{sub w} obtained were inferior in 89 por cent for skull and 83 por cent for abdomen examinations, compared to the values published by SHRIMPTON and WALL. Our measured CTDI{sub w} values were inferior to the values presented for SHRIMPTON and HUDA, for all the age ranges and types of examinations. It was observed that the normalized dose descriptors values in children in the neonatal range were always superior to the values of doses for the adult patient. In abdomen examinations, the difference was approximately 90% for the effective dose (E) and of 57%.for CTDI{sub w} . (author)

  17. Avaliacao da seguranca de diferentes doses de suplementos de acido folico em mulheres do Brasil

    Directory of Open Access Journals (Sweden)

    Quenia dos Santos

    2013-10-01

    Full Text Available OBJETIVO Avaliar a distribuição da ingestão de ácido fólico e a segurança de diferentes doses de suplementos em mulheres em idade reprodutiva. MÉTODOS Foram utilizados dados de consumo a partir de dois dias não consecutivos de registro alimentar de 6.837 mulheres em idade reprodutiva (19 a 40 anos participantes do Inquérito Nacional de Alimentação, módulo da Pesquisa de Orçamentos Familiares 2008-2009. Médias e percentis de consumo habitual de folato natural e ácido fólico foram estimados utilizando o método do National Cancer Institute . Cinco cenários foram simulados somando-se diferentes doses diárias de fortificação (400 mcg, 500 mcg, 600 mcg, 700 mcg e 800 mcg ao ácido fólico oriundo dos alimentos consumidos pelas mulheres. Comparou-se o total de ácido fólico (dieta + suplemento com o nível máximo de ingestão tolerável (UL = 1.000 mcg para definir a dose segura de suplementação. RESULTADOS Mulheres com ingestão habitual de ácido fólico acima do nível máximo de ingestão tolerável foram observadas para doses de suplemento de 800 mcg (7,0% das mulheres. Abaixo desse valor, qualquer dose de suplementação mostrou-se segura. CONCLUSÕES O uso de suplementos de até 700 mcg de ácido fólico mostrou-se seguro.

  18. Analysis of the computed tomography in the acute abdomen; Analise da tomografia computadorizada no abdome agudo

    Energy Technology Data Exchange (ETDEWEB)

    Hochhegger, Bruno [Complexo Hospitalar Santa Casa de Porto Alegre, RS (Brazil); Moraes, Everton [Universidade Federal de Santa Maria (UFSM), RS (Brazil); Haygert, Carlos Jesus Pereira; Antunes, Paulo Sergio Pase [Hospital Universitario de Santa Maria, RS (Brazil); Gazzoni, Fernando [Pontificia Universidade Catolica de Porto Alegre (PUC-RS), Porto Alegre, RS (Brazil). Hospital Sao Lucas; Andrade, Rubens Gabriel Feijo [Fundacao Universitaria de Cardiologia de Porto Alegre, RS (Brazil). Inst. de Cardiologia; Bueno, Leticia Rossi [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil); Lopes, Luis Felipe Dias [Universidade Federal de Santa Maria (UFSM), RS (Brazil). Dept. de Estatistica]. E-mail: brunorgs@pop.com.br

    2007-07-01

    Introduction: This study tends to test the capacity of the computed tomography in assist in the diagnosis and the approach of the acute abdomen. Material and method: This is a longitudinal and prospective study, in which were analyzed the patients with the diagnosis of acute abdomen. There were obtained 105 cases of acute abdomen and after the application of the exclusions criteria were included 28 patients in the study. Results: Computed tomography changed the diagnostic hypothesis of the physicians in 50% of the cases (p < 0.05), and the confidence index in 85.71% of the cases (p 0.014). Computed tomography also altered the management in 46.43% of the cases (p > 0.05), where 78.57% of the patients had surgical indication before computed tomography and 67.86% after computed tomography (p = 0.0546). The index of accurate diagnosis of computed tomography, when compared to the anatomopathologic examination and the final diagnosis, was observed in 82.14% of the cases (p = 0.013). When the analysis was done dividing the patients in surgical and nonsurgical group, were obtained an accuracy of 89.28% (p 0.0001). The difference of 7.2 days of hospitalization (p = 0.003) was obtained compared with the mean of the acute abdomen without use the computed tomography. Conclusion: The computed tomography is correlative with the anatomopathology and has great accuracy in the surgical indication, associated with the capacity of increase the confident index of the physicians, reduces the hospitalization time, reduces the number of surgeries and is cost-effective. (author)

  19. Computed-tomography-guided anatomic standardization for quantitative assessment of dopamine transporter SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Kota [National Center of Neurology and Psychiatry, Department of Radiology, Tokyo (Japan); National Center of Neurology and Psychiatry, Integrative Brain Imaging Center, Tokyo (Japan); Imabayashi, Etsuko; Matsuda, Hiroshi [National Center of Neurology and Psychiatry, Integrative Brain Imaging Center, Tokyo (Japan); Sumida, Kaoru; Sone, Daichi; Kimura, Yukio; Sato, Noriko [National Center of Neurology and Psychiatry, Department of Radiology, Tokyo (Japan); Mukai, Youhei; Murata, Miho [National Center of Neurology and Psychiatry, Department of Neurology, Tokyo (Japan)

    2017-03-15

    For the quantitative assessment of dopamine transporter (DAT) using [{sup 123}I]FP-CIT single-photon emission computed tomography (SPECT) (DaTscan), anatomic standardization is preferable for achieving objective and user-independent quantification of striatal binding using a volume-of-interest (VOI) template. However, low accumulation of DAT in Parkinson's disease (PD) would lead to a deformation error when using a DaTscan-specific template without any structural information. To avoid this deformation error, we applied computed tomography (CT) data obtained using SPECT/CT equipment to anatomic standardization. We retrospectively analyzed DaTscan images of 130 patients with parkinsonian syndromes (PS), including 80 PD and 50 non-PD patients. First we segmented gray matter from CT images using statistical parametric mapping 12 (SPM12). These gray-matter images were then anatomically standardized using the diffeomorphic anatomical registration using exponentiated Lie algebra (DARTEL) algorithm. Next, DaTscan images were warped with the same parameters used in the CT anatomic standardization. The target striatal VOIs for decreased DAT in PD were generated from the SPM12 group comparison of 20 DaTscan images from each group. We applied these VOIs to DaTscan images of the remaining patients in both groups and calculated the specific binding ratios (SBRs) using nonspecific counts in a reference area. In terms of the differential diagnosis of PD and non-PD groups using SBR, we compared the present method with two other methods, DaTQUANT and DaTView, which have already been released as software programs for the quantitative assessment of DaTscan images. The SPM12 group comparison showed a significant DAT decrease in PD patients in the bilateral whole striatum. Of the three methods assessed, the present CT-guided method showed the greatest power for discriminating PD and non-PD groups, as it completely separated the two groups. CT-guided anatomic standardization using

  20. Aspectos da tomografia de coerência óptica na doença de Stargardt: relato de caso Optical coherence tomography aspects of Stargardt's disease: case report

    Directory of Open Access Journals (Sweden)

    Enéias Bezerra Gouveia

    2006-08-01

    Full Text Available O termo fundus flavimaculatus (doença de Stargardt descreve um grupo de distrofias maculares hereditárias caracterizadas por múltiplos "flecks" amarelados em nível do epitélio pigmentar da retina. Os autores descrevem os achados de tomografia de coerência óptica (OCT em paciente portador de doença de Stargardt e sugerem que a OCT tem validade como exame subsidiário no estudo das características da retina de pacientes portadores da doença de Stargardt, embora estudos envolvendo maior número de pacientes sejam indicados para permitir traçar-se o perfil das alterações mais comuns nestes casos.The term fundus flavimaculatus (Stargardt disease describes a group of inherited macular dystrophies characterized by multiple yellow to yellow-white flecks at the level of the retinal pigment epithelium. The authors describe findings in the patient with Stargardt's disease using optical coherence tomography (OCT, and suggest the examination to be valid as subsidiary method in the study of the characteristics of the retina in Stargardt's disease patients, but studies involving a series of patients should be able to show the most frequent findings in these cases.

  1. Combined DaT imaging and olfactory testing for differentiating parkinsonian disorders

    DEFF Research Database (Denmark)

    Borghammer, Per; Knudsen, K; Østergaard, K

    2014-01-01

    ObjectiveDopamine transporter (DaT) imaging with single photon emission computed tomography (SPECT) detects loss of striatal dopaminergic innervation with very high sensitivity. It cannot readily distinguish idiopathic Parkinson's disease (iPD) and dementia with Lewy bodies (DLB) from atypical...... predicted a dopamine-deficient diagnosis with 98% sensitivity and 98% specificity. The combined DaT/olfactory testing correctly classified 91% of patients as iPD/DLB (PPV 91%). The PPV rose to 97% or greater in anosmic patients. In contrast, only 45% of aPD patients were categorised correctly by combined Da...

  2. Retinal thickness measurement and evaluation of natural history of the diabetic macular edema through optical coherence tomography Medida da espessura retiniana e avaliação da história natural do edema macular diabético pela tomografia de coerência óptica

    Directory of Open Access Journals (Sweden)

    Rosana Zacarias Hannouche

    2009-08-01

    influence on the center point thickness data, whereas values of visual acuity were significantly correlated with it. CONCLUSION: This study presents the optical coherence tomography applicability in the detection and semiologic evaluation of diabetic macular edema in patients with visual acuity 20/40 or greater, during one year, showing the retinal thickening in the early stages of diabetic retinopathy. Further, it evidenciated the correlation between the increase in foveal thickness and the reduction in visual acuity. Levels of hemoglobin A1c did not influence the center point thickness data. An early detection of clinically significant macular edema leads us to a redefinition of the real meaning of incipient retinopathy and can prevent further significant reduction of vision.OBJETIVOS: 1 Diagnosticar a presença de edema macular diabético em pacientes com retinopatia diabética e acuidade visual igual ou melhor que 20/40, pela realização do exame de tomografia de coerência óptica, medindo a espessura foveal central, ao longo de um ano. 2 Avaliar a história natural do edema, ao longo de um ano, associando a espessura foveal central com a hemoglobina glicosilada (HbA1c e alterações na acuidade visual. 3 Correlacionar os resultados obtidos com o grupo controle. MÉTODOS: Estudo prospectivo de uma amostra de 30 pacientes, com edema macular diabético e acuidade visual melhor ou igual a 20/40. O estudo contou com 30 olhos como grupo controle. Foram feitas medidas da melhor acuidade visual corrigida, dosagem de hemoglobina glicosilada, biomicroscopia com lente de 78 dioptrias, angiofluoresceinografia e tomografia de coerência óptica. Determinou-se, pelo propósito do estudo, a espessura foveal central como principal variável. Além da estatística descritiva, utilizaram-se testes para análise dos resultados: foi testada a homogeneidade de cada variável pelos testes t-Student, Qui-Quadrado e teste de Tukey; para correlacionar variáveis utilizou-se a análise de

  3. Estudo do metabolismo da glicose na tuberculose pulmonar ativa utilizando a tomografia por emissão de pósitrons (18F-FDG PET Evaluation of glucose metabolism in active lung tuberculosis by positron-emission tomography (18F-FDG PET

    Directory of Open Access Journals (Sweden)

    SIDNEY BOMBARDA

    2002-09-01

    Full Text Available Os métodos de imagem utilizados na avaliação da tuberculose pulmonar incluem a radiografia e a tomografia computadorizada do tórax. As imagens obtidas pelos métodos de medicina nuclear permitem estudos funcionais e metabólicos dos órgãos de interesse, através do uso de radiofármacos específicos. Alterações do metabolismo da glicose podem ser detectadas pela tomografia por emissão de pósitrons (PET utilizando-se o 18F-fluorodesoxiglicose (18F-FDG. Essas alterações estão presentes nas doenças neoplásicas, inflamatórias e infecciosas. A tuberculose é uma doença granulomatosa causada pelo Mycobacterium tuberculosis, que se utiliza de glicose como fonte de energia. Objetivo: O estudo do metabolismo da glicose na tuberculose pulmonar através da PET e sua comparação com a tomografia computadorizada de tórax. Material e métodos: Foram avaliados 20 pacientes portadores de tuberculose pulmonar. Todos foram submetidos à PET e à tomografia computadorizada de tórax, em até 30 dias após o início do tratamento. Resultados: Todos os pacientes apresentaram captação positiva do 18F-FDG na PET. Na tomografia computadorizada do tórax, todos os pacientes apresentaram sinais compatíveis com atividade de tuberculose. A sensibilidade dos dois métodos foi de 100%. Houve concordância entre os achados do 18F-FDG PET e da tomografia computadorizada (K = 0,27 e p Current methods to evaluate lung tuberculosis include chest radiography and computed tomography. Nuclear medicine imaging techniques are performed after administration of specific radiopharmaceuticals that accumulate in the organs of interest. Alterations of glucose metabolism can be observed by positron-emission tomography, using 18F-fluorodeoxyglucose (18F-FDG PET. These findings are present in the neoplasms, but also in inflammatory and infectious diseases. Tuberculosis is a granulomatous disease caused by Mycobacterium tuberculosis , that uses glucose as an energy source

  4. Method of evaluation of diagnostics reference levels in computerized tomography; Metodo de avaliacao de niveis de referencia de radiodiagnostico em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  5. Positron emission tomography molecular imaging of dopaminergic system in drug addiction.

    Science.gov (United States)

    Hou, Haifeng; Tian, Mei; Zhang, Hong

    2012-05-01

    Dopamine (DA) is involved in drug reinforcement, but its role in drug addiction remains unclear. Positron emission tomography (PET) is the first technology used for the direct measurement of components of the dopaminergic system in the living human brain. In this article, we reviewed the major findings of PET imaging studies on the involvement of DA in drug addiction, especially in heroin addiction. Furthermore, we summarized PET radiotracers that have been used to study the role of DA in drug addiction. To investigate presynaptic function in drug addiction, PET tracers have been developed to measure DA synthesis and transport. For the investigation of postsynaptic function, several radioligands targeting dopamine one (D1) receptor and dopamine two (D2) receptor are extensively used in PET imaging studies. Moreover, we also summarized the PET imaging findings of heroin addiction studies, including heroin-induced DA increases and the reinforcement, role of DA in the long-term effects of heroin abuse, DA and vulnerability to heroin abuse and the treatment implications. PET imaging studies have corroborated the role of DA in drug addiction and increase our understanding the mechanism of drug addiction. Copyright © 2012 Wiley Periodicals, Inc.

  6. Comparative study between computed tomography and bronchoscopy in the diagnosis of lung cancer

    International Nuclear Information System (INIS)

    Oliveira, Christopher; Saraiva, Antonio

    2010-01-01

    Objective: to analyze the role of computed tomography and bronchoscopy in the diagnosis of lung cancer, evaluating the effectiveness of these techniques in the presence of this disease. Parameters such as age, gender, smoking habits, histological types, staging and treatment were also analyzed. Materials and methods: the sample of the present study included 70 patients assisted at the Department of Pneumology of Hospital Distrital da Figueira da Foz, Coimbra, Portugal, who were submitted to both diagnostic methods, namely, computed tomography and bronchoscopy, to confirm the presence or the absence of lung cancer. Results: thirty-seven patients (23 men and 14 women) were diagnosed with lung cancer. Histologically 40.54% were adenocarcinoma, followed by squamous carcinoma (32.43% cases) and small-cell lung cancer (18.92%). Staging showed 6.70% stage IB disease, 23.30% stage IIIA and 36.70% stage IIIB, and 33.30% stage IV. Chemotherapy alone was the first treatment of choice for 75.7% of patients. Bronchoscopy sensitivity was 83.8%, specificity 81.8%, and accuracy 82.8%. Computed tomography sensitivity was 81.1%, specificity 63.6%, and accuracy 72.8%. Conclusion: bronchoscopy results corroborated the relevance of the method in the diagnosis of lung cancer, considering its dependence on the anatomopathological study of tissue or cells obtained through different biopsy techniques. Computed tomography presented good sensitivity (81.1%), however the specificity of only 63.6% is related to the rate of false-positive results (36.4%). (author)

  7. Comparative study between computed tomography and bronchoscopy in the diagnosis of lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Christopher; Saraiva, Antonio, E-mail: asaraiva@estescoimbra.p [Escola Superior de Tecnologia da Saude de Coimbra (ESTeSC), Coimbra (Portugal)

    2010-07-15

    Objective: to analyze the role of computed tomography and bronchoscopy in the diagnosis of lung cancer, evaluating the effectiveness of these techniques in the presence of this disease. Parameters such as age, gender, smoking habits, histological types, staging and treatment were also analyzed. Materials and methods: the sample of the present study included 70 patients assisted at the Department of Pneumology of Hospital Distrital da Figueira da Foz, Coimbra, Portugal, who were submitted to both diagnostic methods, namely, computed tomography and bronchoscopy, to confirm the presence or the absence of lung cancer. Results: thirty-seven patients (23 men and 14 women) were diagnosed with lung cancer. Histologically 40.54% were adenocarcinoma, followed by squamous carcinoma (32.43% cases) and small-cell lung cancer (18.92%). Staging showed 6.70% stage IB disease, 23.30% stage IIIA and 36.70% stage IIIB, and 33.30% stage IV. Chemotherapy alone was the first treatment of choice for 75.7% of patients. Bronchoscopy sensitivity was 83.8%, specificity 81.8%, and accuracy 82.8%. Computed tomography sensitivity was 81.1%, specificity 63.6%, and accuracy 72.8%. Conclusion: bronchoscopy results corroborated the relevance of the method in the diagnosis of lung cancer, considering its dependence on the anatomopathological study of tissue or cells obtained through different biopsy techniques. Computed tomography presented good sensitivity (81.1%), however the specificity of only 63.6% is related to the rate of false-positive results (36.4%). (author)

  8. System precision assessment ExacTrac 6D® BrainLab of the Hospital das Clinicas da Faculdade de Medicina da USP; Avaliacao da precisao do sistema Exactrac 6D® BrainLab do Hospital das Clinicas da Faculdade de Medicina da USP

    Energy Technology Data Exchange (ETDEWEB)

    Maistro, Carlos E.B., E-mail: carloseduardo.bravinmaistro@gmail.com [Programa de Residencia Multiprofissional em Fisica Medica, Faculdade de Medicina de Sao Paulo, SP (Brazil); Nakandakari, Marcos V.N.; Ribeiro, Victor A.B.; Sales, Camila P. de; Rodrigues, Laura N. [Universidade de Sao Paulo (USP), SP (Brazil). Instituto de Radiologia. Servico de Radioterapia. Hospital das Clinicas

    2015-08-15

    The goal of this study was to evaluate the precision of ExacTrac 6D® Brainlab system, installed at Hospital das Clinicas da Faculdade de Medicina da USP, in frameless radiosurgery treatments. Four sets of tests were performed for different purposes in order to assess the following parameters: the accuracy of location through infrared system; evaluation of the reproducibility of fusion algorithm; evaluation of the X-ray system; and the end-to-end test with the goal of assess the overall accuracy of the system. It was found that the infrared system showed a maximum deviation of 0.5 mm in terms of positioning and the X-ray system showed a precision of 0.15 mm and 0.6°. The reproducibility of fusion algorithms provided a maximum deviation in position which was less than 0.5 mm and 0.5° and the quantitative analysis of the results for end-to-end test showed an overall accuracy of the system better than 0.8 mm. (author)

  9. Avaliação da concordância interobservadores na análise da polipose nasossinusal por meio da tomografia computadorizada Evaluation of the concordance between observers in sinunasal polyposis through computed tomographic analysis

    Directory of Open Access Journals (Sweden)

    Elaine A. Mendes

    2004-08-01

    Full Text Available Polipose nasossinusal (PNS é uma entidade de etiologia controversa, caracterizada por uma condição inflamatória da superfície mucosa das fossas nasais e seios paranasais, bilateralmente. A queixa principal do paciente consiste na obstrução nasal e, ao exame físico, observam-se freqüentemente massas polipóides ocupando as cavidades nasais em extensões variáveis. Além da rinoscopia anterior e da endoscopia nasal, o uso da tomografia computadorizada (TC torna-se necessário para avaliação das fossas nasais e da presença ou não do acometimento dos seios paranasais por essas massas, bem como a sua extensão. Este trabalho tem como objetivo avaliar a concordância interobservadores, por meio da análise da tomografia computadorizada, de 32 casos de PNS. FORMA DE ESTUDO: Clínico prospectivo. CASUÍSTICA E MÉTODOS: Foram avaliadas 32 TC de pacientes portadores PNS por dois observadores experientes, separadamente, em relação à presença ou não de 3 sinais tomográficos sugestivos dessa doença: (1 alargamento infundibular do complexo ostiomeatal, (2 abaulamento lateral da lâmina papirácea e (3 apagamento do trabeculado ósseo etmoidal. RESULTADOS: Observou-se Qui-quadrado não significante para o primeiro e segundo sinais (p=0,7055 e p=0,2057 e significante para o terceiro (p=0,0040. Contudo, o coeficiente de correlação de Kendall entre os dois observadores foi significante para os três sinais tomográficos acima citados (pSinonasal polyposis (SNP is a condition with a controversial aethiology, known by bilaterally inflammatory mucous membranes of nasal and paranasal sinuses. The major patient's complaint is nasal obstruction, and polypoid masses in different sizes can be found during nasal cavity examination. Beyond anterior rhinoscophy and nasal endoscopy, screening sinus computed tomography (SSCT is necessary to measure the size and the extent of the polyps into nasal cavities and paranasal sinuses. The purpose of this

  10. Translocator Protein-18 kDa (TSPO Positron Emission Tomography (PET Imaging and Its Clinical Impact in Neurodegenerative Diseases

    Directory of Open Access Journals (Sweden)

    Anne-Claire Dupont

    2017-04-01

    Full Text Available In vivo exploration of activated microglia in neurodegenerative diseases is achievable by Positron Emission Tomography (PET imaging, using dedicated radiopharmaceuticals targeting the translocator protein-18 kDa (TSPO. In this review, we emphasized the major advances made over the last 20 years, thanks to TSPO PET imaging, to define the pathophysiological implication of microglia activation and neuroinflammation in neurodegenerative diseases, including Parkinson’s disease, Huntington’s disease, dementia, amyotrophic lateral sclerosis, multiple sclerosis, and also in psychiatric disorders. The extent and upregulation of TSPO as a molecular biomarker of activated microglia in the human brain is now widely documented in these pathologies, but its significance, and especially its protective or deleterious action regarding the disease’s stage, remains under debate. Thus, we exposed new and plausible suggestions to enhance the contribution of TSPO PET imaging for biomedical research by exploring microglia’s role and interactions with other cells in brain parenchyma. Multiplex approaches, associating TSPO PET radiopharmaceuticals with other biomarkers (PET imaging of cellular metabolism, neurotransmission or abnormal protein aggregates, but also other imaging modalities, and peripheral cytokine levels measurement and/or metabolomics analysis was considered. Finally, the actual clinical impact of TSPO PET imaging as a routine biomarker of neuroinflammation was put into perspective regarding the current development of diagnostic and therapeutic strategies for neurodegenerative diseases.

  11. Left lower lobe sleeve lobectomy for lung cancer using the Da Vinci surgical system.

    Science.gov (United States)

    Zhao, Yandong; Jiao, Wenjie; Ren, Xiaoyang; Zhang, Liangdong; Qiu, Tong; Fu, Bo; Wang, Lei

    2016-04-12

    Despite the robotic surgery is widely applied, sleeve lobectomy for lung cancer using the Da Vinci surgical system is still less performed. We described a sleeve lobectomy for adenocarcinoma located at the left lower lobe using the Da Vinci surgical system. A case of 57-year old female referred to our hospital. Computed tomography scan showed an occupation located at the left lower lobe and adenocarcinoma project from the lobe bronchus was diagnosed by bronchoscope examination. A sleeve lobectomy was performed using the Da Vinci surgical system and the postoperative recovery was uneventful. Robotic thoracic surgery is feasible to perform sleeve lobectomy inspite of inadequate experience.

  12. Nonoperative treatment of splenic trauma: usefulness of computed tomography; Tratamento conservador do trauma esplenico: utilidade da tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Resende, Vivian [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Faculdade de Medicina; Tavares Junior, Wilson Campos; Vieira, Jose Nelson Mendes [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Hospital das Clinicas. Dept. de Radiologia e Diagnostico por Imagem]. E-mail: wilsontavaresjrmd@yahoo.fr; Drumond, Domingos Andre Fernandes [Hospital Joao XXIII, Belo Horizonte, MG (Brazil). Setor de Clinica Cirurgica

    2005-04-15

    Objective: to report the results of use of conservative treatment in patients with splenic trauma and to emphasize the usefulness of computed tomography in these cases. Material and method: sixty-nine cases of pediatric patients with blunt abdominal trauma seen from from January 2001 to June 2004 at the level I trauma center were retrospectively studied. Forty-four of these patients were submitted to nonoperative treatment and the clinical follow-up was performed by computerized tomography. All patients had been diagnosed with splenic injury by computerized tomography.Results: the causes of the injuries were motor vehicle accident in 12 (27.2%) patients, bicycle accident in nine (20.4%) patients, and falls in 23 (52.2%) patients. Two (3.7%) patients died from associated injuries. The mean duration of hospital stay was six days. The mean age of the patients was nine years. Conclusion: conservative treatment for blunt splenic trauma is performed with the aim of reducing costs and risks for the patients, and computerized tomography should be routinely used. No posterior complications were observed in this approach. (author)

  13. Pulmonary paracoccidioidomycosis: A case report with high-resolution computed tomography findings

    Directory of Open Access Journals (Sweden)

    M. Armas

    2012-07-01

    Full Text Available Paracoccidioidomycosis is a systemic mycosis which is endemic in rural areas of Latin America, an important European source of immigrants and a growing European touristic destination as well, with most cases occurring in Brazil, Argentina, Venezuela and Colombia. The authors report a case of a 43-year-old man who previously worked in Venezuela and is living in Portugal for 8 years, presenting with a single cutaneous lesion. Despite the absence of valuable respiratory complaints, severe lung damage was found with high-resolution computed tomography (HRCT. Biopsy of the cutaneous lesion and mycologic sputum examination were performed revealing Paracoccidioides brasiliensis infection. Resumo: A Paracoccidioidomicose é uma micose sistémica endémica nas áreas rurais da América Latina, uma fonte importante de imigrantes e destino de emigração e turismo europeu, a maioria dos casos ocorrendo no Brasil, Argentina, Venezuela e Colômbia. Os autores descrevem o caso clínico de um paciente com 43 anos, anteriormente emigrado na Venezuela e residente em Portugal há 8 anos, que se apresenta com lesão cutânea isolada. Embora sem queixas relevantes do foro respiratório, apresentava extensas lesões do parênquima pulmonar caracterizadas por tomografia computorizada de alta resolução (TCAR. Foi realizada biópsia da lesão cutânea e exame micológico da expetoração que revelaram infeção por Paracoccidioides brasiliensis (PB. Keywords: Paracoccidioidomycosis, Paracoccidioides brasiliensis, Pulmonary fibrosis, High-resolution computed tomography, Palavras-chave: Paracoccidioidomicose, Paracoccidioides brasiliensis, Fibrose pulmonar, Tomografia computorizada de alta resolução

  14. Pulmonary leukemic involvement: high-resolution computed tomography evaluation; Comprometimento pulmonar nas leucemias: avaliacao por tomografia computadorizada de alta resolucao

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Ana Paola de [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Programa de Pos-graduacao em Radiologia; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Souza, Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Dept. de Radiologia

    2004-12-01

    Objective: To evaluate the role of high-resolution computed tomography (HRCT) in patients with leukemia and pulmonary symptoms, to establish the main patterns and to correlate them with the etiology. Materials and Methods: This is a retrospective study of the HRCT of 15 patients with leukemia and pulmonary symptoms. The examinations were performed using a spatial high-resolution protocol and were analyzed by two independent radiologists. Results: The main HRCT patterns found were ground-glass opacity (n=11), consolidation (n=9), airspace nodules (n=3), septal thickening (n=3), tree-in-bud pattern (n=3), and pleural effusion (n=3). Pulmonary infection was the most common finding seen in 12 patients: bacterial pneumonia (n=6), fungal infection (n = 4), pulmonary tuberculosis (n=1) and viral infection (n=1). Leukemic pleural infiltration (n=1), lymphoma (n=1) and pulmonary hemorrhage (n=1) were detected in the other three patients. Conclusion: HRCT is an important tool that may suggest the cause of lung involvement, its extension and in some cases to guide invasive procedures in patients with leukemia. (author)

  15. Comparação morfométrica da orelha interna entre ovinos e humanos através da tomografia computadorizada CT-Scan sheep and human inner ear morphometric comparison

    Directory of Open Access Journals (Sweden)

    Valter Ayres Seibel

    2006-06-01

    Full Text Available INTRODUÇÃO: trabalhos sobre o uso de ovelhas em cirurgias experimentais e treinamento em cirurgia otológica são raros. Este estudo pretende contribuir para ampliar o conhecimento nessa área. OBJETIVO: Estudar a orelha interna da ovelha por meio de tomografia computadorizada e cortes sucessivos com o intuito de apresentar dados morfométricos mais precisos relacionados à comparação entre a orelha de ovelhas e a de humanos. MATERIAL E MÉTODO: Foi realizado um estudo descritivo sem seguimento no qual foram comparadas as estruturas da orelha interna da ovelha com as dos humanos. As medidas foram obtidas através de tomografias computadorizadas e avaliadas por meio de um programa de análise de imagens médicas (Osíris 4.16. RESULTADOS: O estudo morfológico da orelha da ovelha, em média, e da orelha humana, em média, revelaram grande similaridade de anatomia. A maior parte das estruturas (10 de 15 preservou a relação proposta de 2/3 da dimensão humana em relação à dimensão ovina. CONCLUSÃO: Os achados contribuem para uso da orelha da ovelha como modelo em cirurgia experimental e treinamento em cirurgia otológica.INTRODUCTION: Studies about the use of sheep in surgical training and experimental otologic surgery are rare. This study intends to contribute to the knowledge on this field. AIM: To study sheep inner ear structures using computerized tomography and serial cross-sections to collect more accurate morphometric data to compare sheep and human ears. MATERIAL AND METHODS: This descriptive study compared the inner structures of sheep and human ears. Measurements were made using computerized tomography, and they were stored in a DICOM compact disc for later analysis and manipulation, with a program used for medical image analysis (Osíris 4.16. RESULTS: Mean measures for sheep and human ears were found to be similar in this morphological study. Most structures (10 out of 15 maintained the 2/3 ratio of sheep to human ear

  16. Algorithmic fundamentals of computerized tomography and of transverse analogue tomography

    International Nuclear Information System (INIS)

    Heckmann, K.

    1981-01-01

    Computerized tomography and transverse analogue tomography are two different approaches to the same goal, namely, transverse tomography. The algorithm is discussed and compared. Transverse tomography appears capable of further development, judging by this comparison. (orig.) [de

  17. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  18. Assessment of natural radioactivity of sands in beaches from Great Vitoria, ES, Brazil; Avaliacao da radioatividade natural em areias das praias da Grande Vitoria, ES

    Energy Technology Data Exchange (ETDEWEB)

    Aquino, Reginaldo Ribeiro de

    2010-07-01

    In this work the concentrations of natural radionuclides {sup 226}Ra, {sup 232}Th and {sup 40}K were determined in superficial sand samples for 16 locations throughout the coast of the Great Victory, metropolitan region of the state of Espirito Santo, Southeast of Brazil. The assessed beaches were Manguinhos and Jacaraipe in Serra county, Camburi, Praia do Canto and Curva da Jurema in Vitoria county, Praia da Costa and Itapua in Vila Velha county, Setibao, Setibinha, Praia do Morro, Praia das Castanheiras and Areia Preta in Guarapari county and sand of the Paulo Cesar Vinha Reserve also located in Guarapari county. Three sand samples of each beach were sealed in 100 mL high density polyethylene flasks. After approximately 4 weeks in order to reach secular equilibrium in the {sup 238}U and {sup 2}'3{sup 2}Th series, the samples were measured by high resolution gamma spectrometry and the spectra analyzed with the WinnerGamma software. The self absorption correction was performed for all samples. The {sup 226}Ra concentration was determined from the weighted average concentrations of {sup 214}Pb and {sup 21}'4Bi, the {sup 232}Th concentration was determined from the weighted average concentrations of {sup 228}Ac, {sup 2}'1{sup 2}Pb and {sup 212}Bi and the concentration of {sup 40}K is determined by its single gamma transition of 1460 keV. The radium equivalent concentration and the external hazard index where obtained from the concentrations of {sup 226}Ra, {sup 232}Th and {sup 4}'0K. {sup 226}Ra concentrations show values varying from 3 +- 1 Bq.kg-1 to 738 +- 38 Bq.kg{sup -1}, with the highest values for the central locality of the Camburi beach. {sup 232}Th concentrations show values varying from 7 +- 3 Bq.kg{sup -1} to 7422 +- 526 Bq.kg{sup -1}, with the highest values for Areia Preta beach. {sup 40}K concentrations show values varying from 14 +- 6 Bq.kg{sup -1} to 638 +- 232 Bq.kg{sup -1}, with the highest values for Areia Preta beach

  19. Turbocharging Quantum Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Gamble, John King [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Nielsen, Erik [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Maunz, Peter Lukas Wilhelm [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Scholten, Travis L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Rudinger, Kenneth Michael [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography suffers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. We describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more effectively detect and characterize quantum noise using carefully tailored ensembles of input states.

  20. Assessment of endogenous dopamine release by methylphenidate challenge using iodine-123 iodobenzamide single-photon emission tomography

    International Nuclear Information System (INIS)

    Booij, J.; Korn, P.; Linszen, D.H.; Royen, E.A. van

    1997-01-01

    This double-blind, placebo-controlled study assessed pharmacologically induced endogenous dopamine (DA) release in healthy male volunteers (n=12). Changes in endogenous DA release after injection of the psychostimulant drug methylphenidate were evaluated by single-photon emission tomography (SPET) and constant infusion of iodine-123 iodobenzamide ([ 123 I[IBZM), a D 2 receptor radioligand that is sensitive to endogenous DA release. Methylphenidate induced displacement of striatal [ 123 I[IBZM binding, resulting in a significantly decrease in the specific to non-specific [ 123 I[IBZM uptake ratio (average: 8.6%) in comparison with placebo (average: -1.9%). Moreover, injection of methylphenidate induced significant behavioural responses on the following items: excitement, anxiety, tension, and mannerisms and posturing. The results of this study demonstrate the feasibility of using constant infusion of [ 123 I[IBZM and SPET imaging to measure endogenous DA release after methylphenidate challenge and to investigate neurochemical aspects of behaviour. (orig.). With 2 figs., 1 tab

  1. Sacroiliitis: imaging evaluation; Sacroiliite: avaliacao por imagem

    Energy Technology Data Exchange (ETDEWEB)

    Montandon, Cristiano; Teixeira, Kim-Ir-Sen Santos [Clinicas da Imagem e Multimagem, Goiania, GO (Brazil); Costa, Marlos Augusto Bitencourt; Carvalho, Tarcisio Nunes; Montandon Junior, Marcelo Eustaquio [Universidade Federal de Goias, Goiania, GO (Brazil). Faculdade de Medicina. Dept. de Diagnostico por Imagem]. E-mail: cmontandon@terra.com.br

    2007-01-15

    Sacroiliitis is a non-infectious inflammatory process involving the sacroiliac joint, and is a diagnostic criterion for seronegative spondyloarthropathies. Imaging methods are of great value for confirming the diagnosis of this condition. The present study is a review of cases included in didactic files and in the literature to illustrate the anatomy, techniques, and main imaging findings in x-ray, computed tomography and magnetic resonance imaging for determining the diagnosis of sacroiliitis, also approaching main differential diagnoses. (author)

  2. Optical tomography of tissues

    International Nuclear Information System (INIS)

    Zimnyakov, D A; Tuchin, Valerii V

    2002-01-01

    Methods of optical tomography of biological tissues are considered, which include pulse-modulation and frequency-modulation tomography, diffusion tomography with the use of cw radiation sources, optical coherent tomography, speckle-correlation tomography of nonstationary media, and optoacoustic tomography. The method for controlling the optical properties of tissues is studied from the point of view of increasing a probing depth in optical coherent tomography. The modern state and prospects of the development of optical tomography are discussed. (review)

  3. Evaluation of home-made teas efficiency from medicinal plants used on childish diarrhea treatment; Avaliacao da eficacia de chas caseiros de plantas medicinais utilizados no tratamento da diarreia infantil

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Magda Moreira; Silva, Maria Jose de Sousa Ferreira da [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Dept. de Quimica; Vilhena Schayer Sabino, Claudia de; Amaral, Angela Maria [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil)

    1996-03-01

    The objective of this work is to verify whether the home-made teas form Brazilian plants, used for control of childish diarrhea have been efficient reaching the composition recommended by World Health Organizations (WHO). This work has been carried out using the neutron activation analysis and the TRIGA MARK I reactor, the IPR-R1, in the Centro de Desenvolvimento da Tecnologia Nuclear - CDTN. (author). 4 refs., 2 tabs.

  4. Usefulness of [18F]-DA and [18F]-DOPA for PET imaging in a mouse model of pheochromocytoma

    International Nuclear Information System (INIS)

    Martiniova, Lucia; Cleary, Susannah; Lai, Edwin W.; Kiesewetter, Dale O.; Seidel, Jurgen; Dawson, Linda F.; Phillips, Jacqueline K.; Thomasson, David; Chen Xiaoyuan; Eisenhofer, Graeme; Powers, James F.; Kvetnansky, Richard

    2012-01-01

    Purpose: To evaluate the usefulness of [ 18 F]-6-fluorodopamine ([ 18 F]-DA) and [ 18 F]-L-6-fluoro-3,4-dihydroxyphenylalanine ([ 18 F]-DOPA) positron emission tomography (PET) in the detection of subcutaneous (s.c.) and metastatic pheochromocytoma in mice; to assess the expression of the norepinephrine transporter (NET) and vesicular monoamine transporters 1 and 2 (VMAT1 and VMAT2), all important for [ 18 F]-DA and [ 18 F]-DOPA uptake. Furthermore, to compare tumor detection by micro-computed tomography (microCT) to magnetic resonance imaging (MRI) in individual mouse. Methods: SUV max values were calculated from [ 18 F]-DA and [ 18 F]-DOPA PET, tumor-to-liver ratios (TLR) were obtained and expression of NET, VMAT1 and VMAT2 was evaluated. Results: [ 18 F]-DA detected less metastatic lesions compared to [ 18 F]-DOPA. TLR values for liver metastases were 2.26–2.71 for [ 18 F]-DOPA and 1.83–2.83 for [ 18 F]-DA. A limited uptake of [ 18 F]-DA was found in s.c. tumors (TLR=0.22-0.27) compared to [ 18 F]-DOPA (TLR=1.56-2.24). Overall, NET and VMAT2 were expressed in all organ and s.c. tumors. However, s.c. tumors lacked expression of VMAT1. We confirmed [ 18 F]-DA's high affinity for the NET for its uptake and VMAT1 and VMAT2 for its storage and retention in pheochromocytoma cell vesicles. In contrast, [ 18 F]-DOPA was found to utilize only VMAT2. Conclusion: MRI was superior in the detection of all organ tumors compared to microCT and PET. [ 18 F]-DOPA had overall better sensitivity than [ 18 F]-DA for the detection of metastases. Subcutaneous tumors were localized only with [ 18 F]-DOPA, a finding that may reflect differences in expression of VMAT1 and VMAT2, perhaps similar to some patients with pheochromocytoma where [ 18 F]-DOPA provides better visualization of lesions than [ 18 F]-DA.

  5. Evaluation of uniformity and noise consistency test in computerized tomography; Avaliacao do teste de constancia de uniformidade e ruido em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Garrafiel, Fabricio N.; Lykawka, Rochelle; Bacelar, Alexandre; Anes, Mauricio [Hospital de Clinicas de Porto Alegre (HCPA), Porto Alegre, RS (Brazil); Alva-Sanchez, Mirko S.; Pianoschi, Thatiane [Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), Porto Alegre, RS (Brazil)

    2016-07-01

    The quality control in computed tomography (CT) includes constancy tests concerning CT number measured in a water tank and its response as uniformity, noise and accuracy. Differences to It's performance limits and frequency established by the national legislation and the manufacturers are well known. The objective of this study was to evaluate these tests proceeding the periodicity of national legislation. The tests were conducted over a three equipment of different manufacturers. Each equipment has acquisition parameters and specific phantoms. The equipment presented adequate performance and consistency when compared their results to the limits determined by manufacturers and national legislation. Thus, it is important to evaluate these differences and tailor the testing protocols to meet the established quality requirements. (author)

  6. Aspectos radiológicos da atresia brônquica: relato de três casos e revisão da literatura Radiological aspects of bronchial atresia: report of three cases and review of the literature

    Directory of Open Access Journals (Sweden)

    Alexandre da Silva Neu

    2003-01-01

    Full Text Available A atresia brônquica é uma anomalia congênita rara que usualmente produz massa justa-hilar com hipertransparência distal à radiografia simples. A maioria dos pacientes é jovem e não apresenta sintomas. A tomografia computadorizada confirma o diagnóstico, permitindo o manejo conservador nos casos assintomáticos. Os autores relatam três casos de atresia brônquica. Um caso, de particular interesse, estava associado a volumosa broncocele em paciente do sexo feminino, de 45 anos de idade, que apresentou quadro sintomático de infecção respiratória. O diagnóstico foi estabelecido por meio dos achados da radiologia convencional, da tomografia computadorizada e da comparação com radiografias convencionais e tomografia linear prévios, que já demonstravam alterações. Realizou-se uma revisão sobre os achados clínicos e radiológicos dessa malformação.Bronchial atresia is a rare congenital abnormality that usually shows a juxta-hilar mass with distal radiolucency on conventional x-ray films. Most patients are young and have no symptoms. Computed tomography usually confirms the diagnosis, allowing conservative management of the asymptomatic cases. The authors report three cases of bronchial obstruction. One of the patients was of particular importance and interest, a 45-year-old female patient with symptoms of respiratory infection, due to the association with a bulky bronchocele. The diagnosis was made by analyzing the findings of conventional x-ray films and computed tomography, and the comparison with previous conventional x-ray films and linear tomography, which had already demonstrated abnormalities. A literature review on the clinical and radiological findings of this pulmonary malformation is presented.

  7. Computerized tomography

    International Nuclear Information System (INIS)

    Rubashov, I.B.

    1985-01-01

    Operating principle is described for the devices of computerized tomography used in medicine for diagnosis of brain diseases. Computerized tomography is considered as a part of computerized diagnosis, as a part of information science. It is shown that computerized tomography is a real existed field of investigations in medicine and industrial production

  8. Tomografia de coerência óptica na commotio retinae: relato de caso Optical coherence tomography imaging in commotio retinae: case report

    Directory of Open Access Journals (Sweden)

    Celso Morita

    2009-08-01

    Full Text Available O objetivo deste relato é correlacionar achados à tomografia de coerência óptica e prognóstico visual de pacientes com commotio retina e de gravidades diferentes. Dois pacientes do sexo masculino, de 20 e 23 anos com baixa visual unilateral após trauma ocular contuso atribuível a edema de Berlin foram avaliados pela retinografia e tomografia de coerência óptica. A acuidade visual no olho afetado era de 20/25 no primeiro paciente e conta dedos a 2 metros no segundo. O exame oftalmológico revelou uveíte traumática e, na fundoscopia, evidenciaram-se opacificação retiniana moderada no primeiro caso e grave no segundo. A tomografia de coerência óptica confirmou discreta diminuição da depressão foveal no primeiro caso e desorganização das camadas retinianas no segundo. Houve resolução anatômica e funcional completa a tomografia de coerência óptica no primeiro paciente, enquanto o segundo evoluiu com baixa visual permanente e desorganização da arquitetura retiniana. A tomografia de coerência óptica é um exame complementar útil na avaliação do trauma retiniano, ajudando a entender sua fisiopatologia e predizer prognóstico a partir da análise anatômica da região acometida.The purpose of this case report was to correlate optical coherence tomography findings and visual outcomes of patients with different degrees of commotio retinae. A 20-year-old male and a 23-year-old male that presented with decreased vision due to Berlin's edema after blunt ocular trauma were evaluated by optical coherence tomography and retinography. The visual acuity in the affected eye was 20/25 in the first patient and counting fingers in the second one. The ophthalmic examination showed traumatic uveitis and fundoscopy revealed mild retinal opacification in the first case and severe opacification in the latter. The optical coherence tomography confirmed the reduction of foveal depression on the first case and the disarrangement of all retinal

  9. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  10. Tomography

    International Nuclear Information System (INIS)

    1985-01-01

    Already widely accepted in medicine, tomography can also be useful in industry. The theory behind tomography and a demonstration of the technique to inspect a motorcycle carburetor is presented. To demonstrate the potential of computer assisted tomography (CAT) to accurately locate defects in three dimensions, a sectioned 5 cm gate valve with a shrink cavity made visible by the sectioning was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +-1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  12. Carcinoma espinocelular do conduto auditivo externo: estudo por tomografia computadorizada de seis casos Squamous cell carcinoma of the external auditory canal: computed tomography findings in six cases

    Directory of Open Access Journals (Sweden)

    Fábio Mota Gonzalez

    2005-06-01

    Full Text Available OBJETIVO: Analisar a importância da avaliação tomográfica da extensão profunda dos carcinomas espinocelulares do conduto auditivo externo. MATERIAIS E MÉTODOS: Foram realizados exames tomográficos com cortes axiais e coronais com janelas para partes moles e óssea em seis pacientes com carcinoma espinocelular do conduto auditivo externo, com idade variando entre 55 e 71 anos, internados no Hospital Heliópolis, no período entre maio de 1995 e dezembro de 2003. RESULTADOS: Dos seis pacientes, todos apresentavam aumento de partes moles no conduto auditivo externo, cinco (83,3% tinham erosão óssea e invasão da orelha média, quatro (66,7% possuíam comprometimento da mastóide e da glândula parótida, três (50% apresentavam invasão da articulação temporomandibular, dois (33,3% tinham invasão da fossa média, do canal carotídeo e linfonodomegalia júgulo-carotídea alta ipisilateral. CONCLUSÃO: A avaliação da extensão tumoral profunda fornecida pela tomografia computadorizada é importante no estadiamento clínico, possibilitando um planejamento terapêutico mais eficaz.OBJECTIVE: To evaluate the role of computed tomography in the assessment of deep extension of squamous cell carcinoma of the external auditory canal. MATERIALS AND METHODS: In the period between May 1995 and December 2003 six patients with squamous cell carcinoma of the external auditory canal were submitted to computed tomography scan at "Hospital Heliópolis", São Paulo, SP, Brazil, including axial and coronal slices with soft tissue and bone algorithms. RESULTS: Thickening of the soft tissue of the external auditory canal was seen in all patients, bone erosion and invasion of the middle ear in five (83.3%, invasion of the mastoid and parotid gland in four (66.7%, invasion of the temporomandibular joint in three (50%, and invasion of the middle cranial fossa, carotid canal and cervical lymph node enlargement in two (33.3% patients. CONCLUSION: Assessment of

  13. Da Vinci Xi Robot-Assisted Penetrating Keratoplasty.

    Science.gov (United States)

    Chammas, Jimmy; Sauer, Arnaud; Pizzuto, Joëlle; Pouthier, Fabienne; Gaucher, David; Marescaux, Jacques; Mutter, Didier; Bourcier, Tristan

    2017-06-01

    This study aims (1) to investigate the feasibility of robot-assisted penetrating keratoplasty (PK) using the new Da Vinci Xi Surgical System and (2) to report what we believe to be the first use of this system in experimental eye surgery. Robot-assisted PK procedures were performed on human corneal transplants using the Da Vinci Xi Surgical System. After an 8-mm corneal trephination, four interrupted sutures and one 10.0 monofilament running suture were made. For each procedure, duration and successful completion of the surgery as well as any unexpected events were assessed. The depth of the corneal sutures was checked postoperatively using spectral-domain optical coherence tomography (SD-OCT). Robot-assisted PK was successfully performed on 12 corneas. The Da Vinci Xi Surgical System provided the necessary dexterity to perform the different steps of surgery. The mean duration of the procedures was 43.4 ± 8.9 minutes (range: 28.5-61.1 minutes). There were no unexpected intraoperative events. SD-OCT confirmed that the sutures were placed at the appropriate depth. We confirm the feasibility of robot-assisted PK with the new Da Vinci Surgical System and report the first use of the Xi model in experimental eye surgery. Operative time of robot-assisted PK surgery is now close to that of conventional manual surgery due to both improvement of the optical system and the presence of microsurgical instruments. Experimentations will allow the advantages of robot-assisted microsurgery to be identified while underlining the improvements and innovations necessary for clinical use.

  14. Da Vinci Xi Robot–Assisted Penetrating Keratoplasty

    Science.gov (United States)

    Chammas, Jimmy; Sauer, Arnaud; Pizzuto, Joëlle; Pouthier, Fabienne; Gaucher, David; Marescaux, Jacques; Mutter, Didier; Bourcier, Tristan

    2017-01-01

    Purpose This study aims (1) to investigate the feasibility of robot-assisted penetrating keratoplasty (PK) using the new Da Vinci Xi Surgical System and (2) to report what we believe to be the first use of this system in experimental eye surgery. Methods Robot-assisted PK procedures were performed on human corneal transplants using the Da Vinci Xi Surgical System. After an 8-mm corneal trephination, four interrupted sutures and one 10.0 monofilament running suture were made. For each procedure, duration and successful completion of the surgery as well as any unexpected events were assessed. The depth of the corneal sutures was checked postoperatively using spectral-domain optical coherence tomography (SD-OCT). Results Robot-assisted PK was successfully performed on 12 corneas. The Da Vinci Xi Surgical System provided the necessary dexterity to perform the different steps of surgery. The mean duration of the procedures was 43.4 ± 8.9 minutes (range: 28.5–61.1 minutes). There were no unexpected intraoperative events. SD-OCT confirmed that the sutures were placed at the appropriate depth. Conclusions We confirm the feasibility of robot-assisted PK with the new Da Vinci Surgical System and report the first use of the Xi model in experimental eye surgery. Operative time of robot-assisted PK surgery is now close to that of conventional manual surgery due to both improvement of the optical system and the presence of microsurgical instruments. Translational Relevance Experimentations will allow the advantages of robot-assisted microsurgery to be identified while underlining the improvements and innovations necessary for clinical use. PMID:28660096

  15. In Vivo Diffuse Optical Tomography and Fluorescence Molecular Tomography

    Directory of Open Access Journals (Sweden)

    Mingze Li

    2010-01-01

    Full Text Available Diffuse optical tomography (DOT and fluorescence molecular tomography (FMT are two attractive imaging techniques for in vivo physiological and psychological research. They have distinct advantages such as non-invasiveness, non-ionizing radiation, high sensitivity and longitudinal monitoring. This paper reviews the key components of DOT and FMT. Light propagation model, mathematical reconstruction algorithm, imaging instrumentation and medical applications are included. Future challenges and perspective on optical tomography are discussed.

  16. Relation between thoracic aortic inflammation and features of plaque vulnerability in the coronary tree in patients with non-ST-segment elevation acute coronary syndrome undergoing percutaneous coronary intervention. An FDG-positron emission tomography and optical coherence tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Taglieri, Nevio; Ghetti, Gabriele; Saia, Francesco; Bacchi Reggiani, Maria Letizia; Rapezzi, Claudio [Alma Mater Studiorum Universita di Bologna, Istituto di Cardiologia, Dipartimento di Medicina Specialistica, Diagnostica e Sperimentale, Bologna (Italy); Nanni, Cristina; Bonfiglioli, Rachele; Lima, Giacomo Maria; Fanti, Stefano [Alma Mater Studiorum Universita di Bologna, Istituto di Medicina Nucleare, Dipartimento di Medicina Specialistica, Diagnostica e Sperimentale, Bologna (Italy); Marco, Valeria [CLI Foundation, Rome (Italy); Prati, Francesco [CLI Foundation, Rome (Italy); Ettore Sansavini Health Science Foundation, GVM Care and Research, Cotignola (Italy)

    2017-10-15

    To evaluate the relationship between aortic inflammation as assessed by {sup 18}F-fluorodeoxyglucose-positron emission tomography ({sup 18}F-FDG-PET) and features of plaque vulnerability as assessed by frequency domain-optical coherence tomography (FD-OCT). We enrolled 30 consecutive non-ST-segment elevation acute coronary syndrome patients undergoing percutaneous coronary intervention. All patients underwent three-vessel OCT before intervention and {sup 18}F-FDG-PET before discharge. Univariable and C-reactive protein (CRP)-adjusted linear regression analyses were performed between features of vulnerability [namely:lipid-rich plaques with and without macrophages and thin cap fibroatheromas (TCFA)] and {sup 18}F-FDG uptake in both ascending (AA) and descending aorta (DA) [measured either as averaged mean and maximum target-to-blood ratio (TBR) or as active slices (TBR{sub max} ≥ 1.6)]. Mean age was 62 years, and 26 patients were male. On univariable linear regression analysis TBR{sub mean} and TBR{sub max} in DA was associated with the number of lipid-rich plaques (β = 4.22; 95%CI 0.05-8.39; p = 0.047 and β = 3.72; 95%CI 1.14-6.30; p = 0.006, respectively). TBR{sub max} in DA was also associated with the number of lipid-rich plaques containing macrophages (β = 2.40; 95%CI 0.07-4.72; p = 0.044). A significant CRP adjusted linear association between the TBR{sub max} in DA and the number of lipid-rich plaques was observed (CRP-adjusted β = 3.58; 95%CI -0.91-6.25; p = 0.01). TBR{sub max} in DA showed a trend towards significant CRP-adjusted association with number of lipid-rich plaques with macrophages (CRP-adjusted β = 2.30; 95%CI -0.11-4.71; p = 0.06). We also observed a CRP-adjusted (β = 2.34; 95%CI 0.22-4.47; p = 0.031) linear association between the number of active slices in DA and the number of lipid-rich plaques. No relation was found between FDG uptake in the aorta and the number of TCFAs. In patients with first NSTEACS{sup ,} {sup 18}F-FDG uptake in

  17. A tomografia computadorizada de alta resolução na avaliação da toxicidade pulmonar por amiodarona High-resolution computed tomography of amiodarone pulmonary toxicity

    Directory of Open Access Journals (Sweden)

    Daniela Peixoto Consídera

    2006-04-01

    Full Text Available OBJETIVO: Avaliar as principais alterações identificadas na tomografia computadorizada de alta resolução do tórax em pacientes com toxicidade pulmonar pela amiodarona. MATERIAIS E MÉTODOS: Foram avaliadas dez tomografias computadorizadas de alta resolução de tórax de pacientes com pneumonite pela amiodarona, seis desses pacientes do sexo masculino e quatro do sexo feminino, com idade média de 73,5 anos. RESULTADOS: Os achados tomográficos mais relevantes foram opacidades lineares ou reticulares em seis casos (60%, pequenos nódulos com densidade elevada em seis casos (60%, consolidações densas em três casos (30% e aumento da densidade do parênquima hepático em cinco de oito casos em que havia estudo tomográfico do abdome superior (62,5%. CONCLUSÃO: A tomografia computadorizada de alta resolução é um exame importante na avaliação de pacientes com toxicidade pulmonar pela amiodarona, devendo ser realizada sempre que houver suspeita deste diagnóstico. O achado de espessamento de septos interlobulares associado a lesões com aumento de densidade é altamente sugestivo deste diagnóstico.OBJECTIVE: To evaluate the main findings of chest high-resolution computed tomography in patients with amiodarone pulmonary toxicity. MATERIALS AND METHODS: Ten patients - six male and four female, average age of 73.5 years - with amiodarone-induced pneumonitis have undergone chest high-resolution computed tomography. RESULTS: The most relevant tomographic findings were linear or reticular opacities in six cases (60%, small high density nodules in six cases (60%, dense consolidations in three cases (30% and increased density in the hepatic parenchyma in five of eight cases in which there was a superior abdomen CT scan (62.5%. CONCLUSION: The high-resolution computed tomography is a valuable non-invasive test for evaluating patients with amiodarone pulmonary toxicity and should always be performed when one suspects of the presence of this

  18. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  19. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  20. The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in resectable pancreatic cancer.

    Science.gov (United States)

    Crippa, Stefano; Salgarello, Matteo; Laiti, Silvia; Partelli, Stefano; Castelli, Paola; Spinelli, Antonello E; Tamburrino, Domenico; Zamboni, Giuseppe; Falconi, Massimo

    2014-08-01

    The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in pancreatic ductal adenocarcinoma is debated. We retrospectively assessed the value of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in addition to conventional imaging as a staging modality in pancreatic cancer. (18)Fluoro-deoxyglucose positron emission tomography/computed tomography was performed in 72 patients with resectable pancreatic carcinoma after multi-detector computed tomography positron emission tomography was considered positive for a maximum standardized uptake value >3. Overall, 21% of patients had a maximum standardized uptake value ≤ 3, and 60% of those had undergone neoadjuvant treatment (P=0.0001). Furthermore, 11% of patients were spared unwarranted surgery since positron emission tomography/computed tomography detected metastatic disease. All liver metastases were subsequently identified with contrast-enhanced ultrasound. Sensitivity and specificity of positron emission tomography/computed tomography for distant metastases were 78% and 100%. The median CA19.9 concentration was 48.8 U/mL for the entire cohort and 292 U/mL for metastatic patients (P=0.112). The widespread application of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in patients with resectable pancreatic carcinoma seems not justified. It should be considered in selected patients at higher risk of metastatic disease (i.e. CA19.9>200 U/mL) after undergoing other imaging tests. Neoadjuvant treatment is significantly associated with low metabolic activity, limiting the value of positron emission tomography in this setting. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  1. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  2. Pneumocystis carinii pneumonia in acquired immunodeficiency syndrome - correlation of high-resolution computed tomography and anatomopathology; Pneumocistose na sindrome da imunodeficiencia adquirida: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson; Moreira, Luiza Beatriz [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia]. E-mail: edmarchiori@zipmail.com.br; Capone, Domenico [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Patologia; Pereira, Cyntia Inez Guedes Soares

    2001-12-01

    We present the main findings observed on the high-resolution computed tomography examinations of 15 patients with acquired immunodeficiency syndrome and Pneumocystis carinii pneumonia. The high-resolution computed tomography and autopsy findings of 5 patients were also compared. The most frequently observed high-resolution computed tomography patterns were ground-glass attenuation, consolidation areas, crazy-paving pattern and cysts. Nodules and intralobular reticulation were less frequently observed. Ground-glass attenuation and consolidation areas corresponded to alveolar filling with inflammatory exudate. Thickening of the interlobular septa was due to cell infiltration and edema. One patient presented interlobular reticulation, and the pathology study revealed alveolar septa thickening due to cell infiltration and fibrosis. Nodules observed in one of the patients corresponded to a patchy intra alveolar accumulation of microorganisms and inflammatory cells forming a 'granulomatous' pattern. (author)

  3. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  4. Multislice helical computed tomography in the evaluation of lumbar spine diseases; Tomografia computadorizada 'multislice' no diagnostico das afeccoes da coluna lombar

    Energy Technology Data Exchange (ETDEWEB)

    Rosemberg, Laercio Alberto; Rios, Adriana Martins; Almeida, Milena Oliveira [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil)]. E-mail: laercio@einstein.br; Garbaccio, Viviane Ladeira; Kim, Nelson Ji Tae; Daniel, Mauro Miguel; Funari, Marcelo Buarque de Gusmao [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil). Dept. de Imagem

    2003-06-01

    Multislice computed tomography has advantages in comparison to conventional computer tomography such as reduction in study time, lower radiation dose, fewer metal artifacts and high quality multiplanar reformatting and three-dimensional reconstructions. We reviewed approximately 300 lumbar spine examinations and selected the most illustrative cases including congenital anomalies, degenerative lesions, spinal infections, neoplasms traumatic injuries, spondylolysis and postoperative changes. In the majority of the cases the high quality multiplanar reformatted and volume reconstructions of multislice computed tomography allowed better evaluation of the lesions, particularly in the cases of complex anatomy (author)

  5. Review of muon tomography

    International Nuclear Information System (INIS)

    Feng Hanliang; Jiao Xiaojing

    2010-01-01

    As a new detection technology, Muon tomography has some potential benefits, such as being able to form a three- dimensional image, without radiation, low cost, fast detecting etc. Especially, muon tomography will play an important role in detecting nuclear materials. It introduces the theory of Muon tomography, its advantages and the Muon tomography system developed by decision sciences corporation and Los Alamos national laboratory. (authors)

  6. Borehole radar diffraction tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seong Jun; Kim, Jung Ho; Yi, Myeong Jong; Chung, Seung Hwan; Lee, Hee Il [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1997-12-01

    Tomography is widely used as imaging method for determining subsurface structure. Among the reconstruction algorithms for tomographic imaging, travel time tomography is almost applied to imaging subsurface. But isolated small body comparable with the wavelength could not be well recognized by travel time tomography. Other tomographic method are need to improve the imaging process. In the study of this year, diffraction tomography was investigated. The theory for diffraction tomography is based on the 1st-order Born approximation. Multisource holography, which is similar to Kirchihoff migration, is compared with diffraction tomography. To improve 1st-order Born diffraction tomography, two kinds of filter designed from multisource holography and 2-D green function, respectively, applied on the reconstructed image. The algorithm was tested for the numerical modeling data of which algorithm consists of the analytic computation of radar signal in transmitter and receiver regions and 2-D FDM scheme for the propagation of electromagnetic waves in media. The air-filled cavity model to show a typical diffraction pattern was applied to diffraction tomography imaging, and the result shows accurate location and area of cavity. But the calculated object function is not well matched the real object function, because the air-filled cavity model is not satisfied week scattered inhomogeneity for 1st born approximation, and the error term is included in estimating source wavelet from received signals. In spite of the object function error, the diffraction tomography assist for interpretation of subsurface as if conducted with travel time tomography. And the fracture model was tested, 1st born diffraction tomographic image is poor because of limited view angle coverage and violation of week scatter assumption, but the filtered image resolve the fracture somewhat better. The tested diffraction tomography image confirms effectiveness of filter for enhancing resolution. (author). 14

  7. Evaluation of the natural radioactivity at sands of anomalous regions of Espirito Santo state, Brazil; Avaliacao da radioatividade natural em areias de regioes anomalas do Espirito Santo, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Aquino, Reginaldo Ribeiro de; Pecequilo, Brigitte Roxana Soreanu, E-mail: raquino@ipen.b, E-mail: brigitte@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-10-26

    The natural radioactivity in sands of anomalous regions of the state of Espirito Santo, Brazil, were calculated from the concentration of activity of {sup 40}K, {sup 225}Ra and {sup 232}Th for the places of south and central of Camburi, Curva da Jurema, Ilha do Boi, Setibinha, south and central area of Praia da Areia Preta, denominated Black Spot. The samples were sealed and measured by high resolution gamma spectrometry and after a expectation time pf 30 days, until to reach a radioactive equilibrium

  8. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  10. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  13. Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography and (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for recurrent prostate carcinoma: results of a prospective clinical trial.

    Science.gov (United States)

    Schuster, David M; Nieh, Peter T; Jani, Ashesh B; Amzat, Rianot; Bowman, F Dubois; Halkar, Raghuveer K; Master, Viraj A; Nye, Jonathon A; Odewole, Oluwaseun A; Osunkoya, Adeboye O; Savir-Baruch, Bital; Alaei-Taleghani, Pooneh; Goodman, Mark M

    2014-05-01

    We prospectively evaluated the amino acid analogue positron emission tomography radiotracer anti-3-[(18)F]FACBC compared to ProstaScint® ((111)In-capromab pendetide) single photon emission computerized tomography-computerized tomography to detect recurrent prostate carcinoma. A total of 93 patients met study inclusion criteria who underwent anti-3-[(18)F]FACBC positron emission tomography-computerized tomography plus (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for suspected recurrent prostate carcinoma within 90 days. Reference standards were applied by a multidisciplinary board. We calculated diagnostic performance for detecting disease. In the 91 of 93 patients with sufficient data for a consensus on the presence or absence of prostate/bed disease anti-3-[(18)F]FACBC had 90.2% sensitivity, 40.0% specificity, 73.6% accuracy, 75.3% positive predictive value and 66.7% negative predictive value compared to (111)In-capromab pendetide with 67.2%, 56.7%, 63.7%, 75.9% and 45.9%, respectively. In the 70 of 93 patients with a consensus on the presence or absence of extraprostatic disease anti-3-[(18)F]FACBC had 55.0% sensitivity, 96.7% specificity, 72.9% accuracy, 95.7% positive predictive value and 61.7% negative predictive value compared to (111)In-capromab pendetide with 10.0%, 86.7%, 42.9%, 50.0% and 41.9%, respectively. Of 77 index lesions used to prove positivity histological proof was obtained in 74 (96.1%). Anti-3-[(18)F]FACBC identified 14 more positive prostate bed recurrences (55 vs 41) and 18 more patients with extraprostatic involvement (22 vs 4). Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography correctly up-staged 18 of 70 cases (25.7%) in which there was a consensus on the presence or absence of extraprostatic involvement. Better diagnostic performance was noted for anti-3-[(18)F]FACBC positron emission tomography-computerized tomography than for (111)In-capromab pendetide single

  14. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  15. Single photon emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-09-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) imaging technique. Content: 1 - Introduction: anatomic, functional and molecular imaging; Principle and role of functional or molecular imaging; 2 - Radiotracers: chemical and physical constraints, main emitters, radioisotopes production, emitters type and imaging techniques; 3 - Single photon emission computed tomography: gamma cameras and their components, gamma camera specifications, planar single photon imaging characteristics, gamma camera and tomography; 4 - Quantification in single photon emission tomography: attenuation, scattering, un-stationary spatial resolution, partial volume effect, movements, others; 5 - Synthesis and conclusion

  16. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  17. Cadaveric feasibility study of da Vinci Si-assisted cochlear implant with augmented visual navigation for otologic surgery.

    Science.gov (United States)

    Liu, Wen P; Azizian, Mahdi; Sorger, Jonathan; Taylor, Russell H; Reilly, Brian K; Cleary, Kevin; Preciado, Diego

    2014-03-01

    To our knowledge, this is the first reported cadaveric feasibility study of a master-slave-assisted cochlear implant procedure in the otolaryngology-head and neck surgery field using the da Vinci Si system (da Vinci Surgical System; Intuitive Surgical, Inc). We describe the surgical workflow adaptations using a minimally invasive system and image guidance integrating intraoperative cone beam computed tomography through augmented reality. To test the feasibility of da Vinci Si-assisted cochlear implant surgery with augmented reality, with visualization of critical structures and facilitation with precise cochleostomy for electrode insertion. Cadaveric case study of bilateral cochlear implant approaches conducted at Intuitive Surgical Inc, Sunnyvale, California. Bilateral cadaveric mastoidectomies, posterior tympanostomies, and cochleostomies were performed using the da Vinci Si system on a single adult human donor cadaveric specimen. Radiographic confirmation of successful cochleostomies, placement of a phantom cochlear implant wire, and visual confirmation of critical anatomic structures (facial nerve, cochlea, and round window) in augmented stereoendoscopy. With a surgical mean time of 160 minutes per side, complete bilateral cochlear implant procedures were successfully performed with no violation of critical structures, notably the facial nerve, chorda tympani, sigmoid sinus, dura, or ossicles. Augmented reality image overlay of the facial nerve, round window position, and basal turn of the cochlea was precise. Postoperative cone beam computed tomography scans confirmed successful placement of the phantom implant electrode array into the basal turn of the cochlea. To our knowledge, this is the first study in the otolaryngology-head and neck surgery literature examining the use of master-slave-assisted cochleostomy with augmented reality for cochlear implants using the da Vinci Si system. The described system for cochleostomy has the potential to improve the

  18. Filosofia da análise da estabilidade da liquidez

    Directory of Open Access Journals (Sweden)

    Rodrigo Antônio Chaves da Silva

    2005-07-01

    Full Text Available A informação foi considerada finalidade de nosso conhecimento, até o período em os pensadores e pesquisadores da contabilidade passaram a raciocinar sobre o conteúdo e o significado dos informes. Nesta busca da razão sobre os estados patrimoniais, surgiu a análise contábil que procura por meio de relações e identidades, o significado da dinâmica expressa da estaticamente na informação. O primeiro aspecto que surgiu no objeto de análise foi o estudo da liquidez, que é um dos principais exercícios do patrimônio. A estabilidade também é outro exercício básico e imprescindível, pois este é que promove o equilíbrio do organismo administrativo. A ciência contábil após a sua dignidade científica passou a trilhar caminhos esplendorosos, amparados em doutrina que permite alcançar os píncaros filosóficos. Os estudos concernentes aos aspectos de interação da estabilidade na liquidez são, complexos e somente com os recursos filosóficos da contabilidade se pode estudá-los com o panorama holístico e sublime. A filosofia da contabilidade não é alheia às suas práticas tecnológicas, podendo buscar pontos sublimes de panoramas abrangentes, para o estudo analítico da liquidez e estabilidade, observando todas as dimensionalidades e essencialidades de acontecimentos, na comprovação e orientação dos estados de ineficácia e eficácia patrimonial.

  19. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography

    International Nuclear Information System (INIS)

    Kettler, Nele

    2011-01-01

    Imaging methods for early, accurate diagnosis and aftercare of malignant growths is currently one of the most important research topics. The objective of this thesis is to evaluate the diagnostic value of FDG-positron emission tomography by comparison with computed tomography for patients with squamous cell carcinoma, malignant melanoma or sarcoma at head and neck. Measurement criteria are sensitivity and specificity. A retrospective evaluation of 100 examinations on 85 patients of University clinic Aachen was performed. The examination reports were supported by reports from histology, positron emission tomography and computed tomography. In each case, the histological results were assumed to provide a reliable benchmark. Sensitivity and specificity for the primary tumour site, metastatic lymphatic nodes and defined anatomic structures were compared across all patients. Comparisons were also performed on sub groups separated by gender, cancer type and the time and frequency at which tumours arose. The statistic analysis was done with MedCalc. Results: The results for sensitivity and specificity of the primary tumour site were 86.42% and 42.86%, and 64.71% and 66.07%, for positron emission tomography and computed tomography respectively. The results for the lymphatic nodes were 51.52% and 92.86% and 64.71% and 66.07%. When the constituent anatomic structures were evaluated separately, the specificity was significantly higher. The separation by gender showed no difference. Because the classification by tumor type resulted in samples that were of varying size, a comparison was difficult. For the diagnosis of primary tumours, the examination with positron emission tomography was superior, whereas computed tomography proved more effective for the diagnosis of recurrent tumours. For the diagnosis of the main tumour site, both methods were shown to be equally suitable. For the assessment of lymphatic nodes, positron emission tomography was superior to computed tomography

  20. Computed tomography of mast cell tumors in dogs: assessment before and after chemotherapy; Tomografia computadorizada de mastocitomas em caes: avaliacao pre e pos-tratamento quimioterapico

    Energy Technology Data Exchange (ETDEWEB)

    Lorigados, Carla A.B.; Matera, Julia Maria; Pinto, Ana Carolina B.C.F.; Macedo, Thais R., E-mail: clorigados@usp.br [Universidade de Sao Paulo (FMVZ/USP), SP (Brazil). Fac. de Medicina Veterinaria e Zootecnia. Dept. de Cirurgia; Coppi, Antonio A.; Ladd, Fernando V.L. [Universidade de Sao Paulo (LSSCA/USP), SP (Brazil). Fac. de Medicina Veterinaria e Zootecnia. Lab. de Estereologia Estocastica e Anatomia Quimica; Souza, Vanessa A.F. de [Faculdades Metropolitanas Unidas (FMU), Sao Paulo, SP (Brazil). Curso de Medicina Veterinaria

    2013-11-15

    Nineteen dogs with mast cell tumors treated with chemotherapy were evaluated by computed tomography (CT). Were evaluated aspects related to contours, attenuation, postcontrast enhancement and presence of cleavage with adjacent structures. The RECIST criteria and volumetric measurement of lesions were performed to assess the response to treatment. The mast cell tumors presented a homogeneous or heterogeneous attenuation, presented more frequently a well delineated and regular contours and moderate enhancement after intravenous administration of the iodinated contrast media. The methods RECIST and volumetric measurements showed an excellent agreement to the classification of therapeutic response, providing a good parameter of the response to treatment. The CT examination proved to be useful in the delimitation of the tumor and an important tool for planning of surgical margins. (author)

  1. Meaning of Interior Tomography

    Science.gov (United States)

    Wang, Ge; Yu, Hengyong

    2013-01-01

    The classic imaging geometry for computed tomography is for collection of un-truncated projections and reconstruction of a global image, with the Fourier transform as the theoretical foundation that is intrinsically non-local. Recently, interior tomography research has led to theoretically exact relationships between localities in the projection and image spaces and practically promising reconstruction algorithms. Initially, interior tomography was developed for x-ray computed tomography. Then, it has been elevated as a general imaging principle. Finally, a novel framework known as “omni-tomography” is being developed for grand fusion of multiple imaging modalities, allowing tomographic synchrony of diversified features. PMID:23912256

  2. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  3. Positron emission tomography

    International Nuclear Information System (INIS)

    Wienhard, K.; Heiss, W.D.

    1984-01-01

    The principles and selected clinical applications of positron emission tomography are described. In this technique a chemical compound is labeled with a positron emitting isotope and its biochemical pathway is traced by coincidence detection of the two annihilation photons. The application of the techniques of computed tomography allows to reconstruct the spatial distribution of the radioactivity within a subject. The 18 F-deoxyglucose method for quantitative measurement of local glucose metabolism is discussed in order to illustrate the possibilities of positron emission tomography to record physiological processes in vivo. (orig.) [de

  4. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  5. Single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.

    1986-01-01

    Single photon tomography dates from the early 1960's when the idea of emission transverse section tomography was presented by Kuhl and Edwards. They used a rectilinear scanner and analogue back-projection methods to detect emissions from a series of sequential positions transverse to the cephaldcaudad axis of the body. This chapter presents an explanation of emission tomography by describing longitudinal and transverse section tomography. In principle all modes of tomography can be considered under the general topic of coded apertures wherein the code ranges from translation of a pinhole collimator to rotation of a parallel hole or focused collimator array

  6. Conjecturas da Epistemológia Jurídica e Aspectos da Teoria da Linguagem

    OpenAIRE

    Oliveira, Rita de Cássia Cartelli de; Cesumar; Motta, Ivan Dias; Cesumar

    2008-01-01

    Apresentar-se-ão reflexões em torno da epistemologia jurídica e alguns aspectos da teoria da linguagem; a necessidade de acompanhamento e aprimoramento da linguagem jurídica, para que o direito não se distancie da realidade, mantendo-se apenas como um sistema do status quo; uma breve análise de algumas teorias da ciência do direito e da linguagem; as especificidades dos termos lingüísticos para a análise da ciência do direito, pautada na contemporaneidade sob a perspectiva humanista, buscando...

  7. Tomography

    International Nuclear Information System (INIS)

    Barrett, H.H.; Gordon, S.; Swindell, W.

    1980-01-01

    Apparatus is described for generating a two-dimensional back-projected image of a slice of an object in tomography. The apparatus uses optical techniques to perform the functions of filtering and back projection. Central to the technique is a cylindrical drum which rotates at a fast rate and whose rotational axis tilts at a slower rate. The novel method overcomes the problem of image blurring due to motion which occurs in many tomographic techniques. It also has the advantages of being less expensive and simpler compared to tomography using digital processing techniques which require fast computers. (UK)

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  9. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  10. Iterative methods for tomography problems: implementation to a cross-well tomography problem

    Science.gov (United States)

    Karadeniz, M. F.; Weber, G. W.

    2018-01-01

    The velocity distribution between two boreholes is reconstructed by cross-well tomography, which is commonly used in geology. In this paper, iterative methods, Kaczmarz’s algorithm, algebraic reconstruction technique (ART), and simultaneous iterative reconstruction technique (SIRT), are implemented to a specific cross-well tomography problem. Convergence to the solution of these methods and their CPU time for the cross-well tomography problem are compared. Furthermore, these three methods for this problem are compared for different tolerance values.

  11. Fluorodeoxyglucose-positron emission tomography/computed tomography imaging features of colloid adenocarcinoma of the lung: a case report.

    Science.gov (United States)

    Wang, ZhenGuang; Yu, MingMing; Chen, YueHua; Kong, Yan

    2017-07-27

    Colloid adenocarcinoma of the lung is a rare subtype of variants of invasive adenocarcinomas. We report the appearance of this unusual entity on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography. A 60-year-old man of Chinese Han nationality coughed with a little white sputum for 1 month. Chest computed tomography showed multiple bilateral subpleural nodules and plaques accompanied by air bronchograms, which were most concentrated in the lower lobe of his right lung. Positron emission tomography indicated increased radioactivity uptake with a maximum standardized uptake value of 3.5. Positron emission tomography/computed tomography showed a soft tissue density lesion in his left adrenal gland with a maximum standardized uptake value of 4.1. The positron emission tomography/computed tomography appearance suggested a primary colloid adenocarcinoma in the lower lobe of his right lung accompanied by intrapulmonary and left adrenal gland metastases. The diagnostic rate of colloid adenocarcinoma can be increased by combining the anatomic and metabolic information of lesions. The advantage of positron emission tomography/computed tomography in the diagnosis of colloid adenocarcinoma, as with other cancers, is the ability to locate extrapulmonary disease, facilitating clinical staging.

  12. Imaging atherosclerosis with hybrid [18F]fluorodeoxyglucose positron emission tomography/computed tomography imaging: what Leonardo da Vinci could not see.

    Science.gov (United States)

    Cocker, Myra S; Mc Ardle, Brian; Spence, J David; Lum, Cheemun; Hammond, Robert R; Ongaro, Deidre C; McDonald, Matthew A; Dekemp, Robert A; Tardif, Jean-Claude; Beanlands, Rob S B

    2012-12-01

    Prodigious efforts and landmark discoveries have led toward significant advances in our understanding of atherosclerosis. Despite significant efforts, atherosclerosis continues globally to be a leading cause of mortality and reduced quality of life. With surges in the prevalence of obesity and diabetes, atherosclerosis is expected to have an even more pronounced impact upon the global burden of disease. It is imperative to develop strategies for the early detection of disease. Positron emission tomography (PET) imaging utilizing [(18)F]fluorodeoxyglucose (FDG) may provide a non-invasive means of characterizing inflammatory activity within atherosclerotic plaque, thus serving as a surrogate biomarker for detecting vulnerable plaque. The aim of this review is to explore the rationale for performing FDG imaging, provide an overview into the mechanism of action, and summarize findings from the early application of FDG PET imaging in the clinical setting to evaluate vascular disease. Alternative imaging biomarkers and approaches are briefly discussed.

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  15. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  16. Incidental head and neck findings on 18F-fluoro-deoxy-glucose positron emission tomography computed tomography.

    Science.gov (United States)

    Williams, S P; Kinshuck, A J; Williams, C; Dwivedi, R; Wieshmann, H; Jones, T M

    2015-09-01

    The overlapping risk factors for lung and head and neck cancer present a definite risk of synchronous malignant pathology. This is the first study to specifically review incidental positron emission tomography computed tomography findings in the head and neck region in lung carcinoma patients. A retrospective review was performed of all lung cancer patients who underwent positron emission tomography computed tomography imaging over a five-year period (January 2008 - December 2012), identified from the Liverpool thoracic multidisciplinary team database. Six hundred and nine patients underwent positron emission tomography computed tomography imaging over this period. In 76 (12.5 per cent) scans, incidental regions of avid 18F-fluoro-deoxy-glucose uptake were reported in the head and neck region. In the 28 patients who were fully investigated, there were 4 incidental findings of malignancy. In lung cancer patients undergoing investigative positron emission tomography computed tomography scanning, a significant number will also present with areas of clinically significant 18F-fluoro-deoxy-glucose uptake in the head and neck region. Of these, at least 5 per cent may have an undiagnosed malignancy.

  17. An introduction to emission computed tomography

    International Nuclear Information System (INIS)

    Williams, E.D.

    1985-01-01

    This report includes salient features of the theory and an examination of practical considerations for someone who is using or introducing tomography, selecting equipment for it or wishing to develop a clinical application. Emphasis is on gamma camera tomography. The subject is dealt with under the following headings: emission computed and gamma camera tomography and the relationship to other medical imaging techniques, the tomographic reconstruction technique theory, rotating gamma camera tomography, attenuation correction and quantitative reconstruction, other single photon tomographic techniques, positron tomography, image display, clinical application of single photon and positron tomography, and commercial systems for SPECT. Substantial bibliography. (U.K.)

  18. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  19. Cardiac positron emission tomography

    International Nuclear Information System (INIS)

    Eftekhari, M.; Ejmalian, G.

    2003-01-01

    Positron emission tomography is an intrinsically tool that provide a unique and unparalleled approach for clinicians and researchers to interrogate the heart noninvasively. The ability to label substances of physiological interest with positron-emitting radioisotopes has permitted insight into normal blood flow and metabolism and the alterations that occur with disease states. Positron emission tomography of the heart has evolved as a unique, noninvasive approach for the assessment of myocardial perfusion, metabolism, and function. Because of the intrinsic quantitative nature of positron emission tomography measurements as well as the diverse compounds that can be labeled with positron- emitting radioisotopes, studies with positron emission tomography have provided rich insight into the physiology of the heart under diverse conditions

  20. Nasoangiofibroma juvenil: concordância interobservadores no estadiamento por tomografia computadorizada Juvenile nasopharyngeal angiofibroma: interobserver agreement in cancer staging using computed tomography

    Directory of Open Access Journals (Sweden)

    Jefferson Luiz Gusso

    2001-08-01

    Full Text Available Com o advento da tomografia computadorizada, a avaliação dos locais de acometimento e extensão do nasoangiofibroma juvenil tornou-se mais precisa, o que facilitou o correto estadiamento pré-operatório. O objetivo deste trabalho é avaliar a concordância interobservadores, por meio da análise por tomografia computadorizada, de 15 casos de nasoangiofibroma juvenil em relação à extensão para locais relacionados com altos índices de recidivas. Todos os pacientes eram do sexo masculino, com idade média de 15,8 anos. A análise da concordância entre os observadores quanto à extensão e envolvimento da fossa infratemporal, seios esfenóide e cavernoso e fossa craniana média foi excelente, em relação à fissura orbitária superior foi boa e em relação à base do processo pterigóide e fossa craniana anterior foi ruim. Concluiu-se que a análise apresenta alta concordância entre os observadores para os locais estabelecidos, com exceção da base do processo pterigóide e da fossa craniana anterior.The advent of computed tomography permitted a much more precise evaluation of tumor localization, thus facilitating presurgical staging. The objective of this study was to evaluate the interobserver agreement on the analysis of computed tomography scans of 15 patients with juvenile nasopharyngeal angiofibroma, regarding assessment of tumor extension to sites of high recurrence rate. All patients were male and had a mean age of 15.8 years. The results of the interobserver agreement analysis regarding tumor invasion and extension to the infratemporal fossa, cavernous sinus, sphenoid sinus and medium cranial fossa were excellent. Identification of involvement of the superior orbital fissure was considered good. Interobserver agreement regarding tumor extension to the base of pterigoid process and anterior cranial fossa was considered poor. We concluded that there is a very good interobserver agreement on the evaluation of the established

  1. Positron emission tomography with Positome, 2

    International Nuclear Information System (INIS)

    Nukui, Hideaki; Yamamoto, Y.L.; Thompson, C.J.; Feindel, W.

    1979-01-01

    Positron emission tomography with Positome II using 68 Ga-EDTA was performed in cases with brain tumor and cerebral arteriovenous malformation. A significant focal uptake in static study and hemodynamic changes in dynamic study were noted in all cases except one case with intracranial lipoma. Comparing this method with sup(99m) Tc-pertechnetate cerebral image study and computerized axial tomography, the diagnostic rate for detecting brain tumor was almost equal in all of these three methods. However, detecting and localizing was easier and clearer in static positron emission tomography with 68 Ga-EDTA than in sup(99m) Tc-pertechnetate cerebral image and computerized axial tomography without infusion of contrast medium. Furthermore, static positron emission tomography with 68 Ga-EDTA was superior to computerized axial tomography without infusion of contrast medium for detecting cerebral arteriovenous malformation. Concerning dynamic positron emission tomography with 68 Ga-EDTA, semiquantitative values obtained by this method correlated well with findings of computerized axial tomography and was thought to be more precise and in detail than the findings of sup(99m) Tc-pertechnetate cerebral image study. Summation of the previous studies about dynamic positron emission tomography with 77 Kr in occlusive cerebrovascular disease is also reported. In conclusion, static positron emission tomography with 68 Ga-EDTA is a very useful diagnostic method for detecting and localizing brain tumor and cerebral arteriovenous malformation without any attendant complications. Furthermore, a good combination of static and dynamic positron emission tomography and computerized axial tomography appear to be outstandingly effective for not only detecting the lesion but also understanding the pathophysiological aspect in cases with various intracranial lesions. (author)

  2. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  3. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and

  4. Gamma tomography apparatus

    International Nuclear Information System (INIS)

    Span, F.J.

    1988-01-01

    The patent concerns a gamma tomography apparatus for medical diagnosis. The apparatus comprises a gamma scintillation camera head and a suspension system for supporting and positioning the camera head with respect for the patient. Both total body scanning and single photon emission tomography can be carried out with the apparatus. (U.K.)

  5. Computerised Axial Tomography (CAT)

    Science.gov (United States)

    1990-06-01

    Ministry of’ Defence, Defence Research Information Centre, UK. Computerised Axial Tomography ( CAT ) Report Secufty C"uMiauion tide Onadtiicadon (U. R, Cor S...DRIC T 8485 COMPUTERISED AXIAL TOMOGRAPHY ( CAT ) F.P. GENTILE, F. SABETTA, V. TRO1* ISS R 78/4.Rome, 1.5 Mlarch 1978 (from Italian) B Distribution(f...dello Radiazioni ISSN 0390--6477 F.P. GENTILE, F. SABETTA. V. TROI Computerised Axial Tomography ( CAT ) March 15, 1978). This paper is a review of

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  7. Multidetector-row helical computed tomography in the evaluation of cervical spine disorders; Tomografia computadorizada multislice no diagnostico das afeccoes da coluna cervical

    Energy Technology Data Exchange (ETDEWEB)

    Rosemberg, Laercio Alberto; Almeida, Milena Oliveira; Rios, Adriana Martins; Garbaccio, Viviane Ladeira; Kim, Nelson Ji Tae; Daniel, Mauro Miguel; Funari, Marcelo Buarque de Gusmao [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil). Dept. de Imagem]. E-mail: laercio@einstein.br

    2003-07-01

    Multidetector-row computed tomography (MRCT) has advantages in comparison to conventional helical computed tomography, such as reduction of study time, lower radiation doses, fewer metallic artifacts and high quality multiplanar reformatting and three dimensional reconstructions. We reviewed 150 cervical spine examinations and selected the most illustrative cases including congenital anomalies, degenerative lesions, spinal infections, neoplasms, traumatic injuries and postoperative abnormalities. The quality of multiplanar reformatting and volume reconstructions of the MRCT made the detection and evaluation of most of cases with complex anatomy easier and more precise. (author)

  8. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  9. Apendicite aguda: achados na tomografia computadorizada - ensaio iconográfico Acute appendicitis: computed tomography findings - an iconographic essay

    Directory of Open Access Journals (Sweden)

    Marcelo Eustáquio Montandon Júnior

    2007-06-01

    Full Text Available A apendicite aguda é a causa mais comum de dor abdominal aguda que requer intervenção cirúrgica no mundo ocidental. O diagnóstico precoce é essencial para minimizar a morbidade da doença. O uso dos métodos de imagem significou grande avanço no diagnóstico desta entidade, até então avaliada apenas com base na história clínica, exame físico e dados laboratoriais, haja vista que 20% a 33% dos pacientes apresentam sintomas atípicos. O diagnóstico é mais difícil nas crianças, nos idosos e nas mulheres em idade fértil. Os principais métodos de imagem para sua avaliação são a ultra-sonografia e a tomografia computadorizada. Os objetivos deste trabalho são: descrever a fisiopatologia da doença, comentar os principais aspectos técnicos da tomografia computadorizada, demonstrar e ilustrar os achados tomográficos e citar os principais diagnósticos diferenciais.Acute appendicitis is the most important cause of abdominal pain requiring surgical intervention in the Western world. The early diagnosis of this disease is of paramount relevance for minimizing its morbidity. Imaging methods have represented a huge progress in the diagnosis of this entity, which used to be based essentially on clinical history, physical examination and laboratory tests results, considering that 20% to 33% of patients present with atypical symptoms. Diagnostic difficulty is higher in children, the elderly, and women in childbearing age. The main imaging methods for evaluation of acute appendicitis are ultrasound and computed tomography. The present study is aimed at describing the disease physiopathology, commenting main computed tomography technical aspects, demonstrating and illustrating tomographic findings, and describing main differential diagnoses.

  10. Histiocitoma fibroso benigno profundo: achados na tomografia computadorizada e histologia Deep benign fibrous histiocytoma: computed tomography and histology findings

    Directory of Open Access Journals (Sweden)

    Luciano Farage

    2005-04-01

    Full Text Available Apresentamos imagens de tomografia computadorizada de um paciente de 83 anos de idade com histiocitoma fibroso benigno profundo, na face lateral da perna esquerda, com evolução de longa data. À tomografia computadorizada observamos massa bem delimitada, ovalada, e que apresentava intenso realce periférico com uso do meio de contraste iodado. Este é um tumor de partes moles pouco freqüente e com raros relatos dos seus aspectos de imagem.We present the computed tomography images of an 83-year-old male patient with a deep benign fibrous histiocytoma at the lateral aspect of the left leg. Computed tomography images showed a well-defined mass with marked peripheral enhancement by iodinated contrast medium. Only few reports of this rare soft tissue tumor can be found in the literature.

  11. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Disseminated Cryptococcosis.

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography-computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm.

  12. Prediction of optimal deployment projection for transcatheter aortic valve replacement: angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography.

    OpenAIRE

    Binder Ronald K; Leipsic Jonathon; Wood David; Moore Teri; Toggweiler Stefan; Willson Alex; Gurvitch Ronen; Freeman Melanie; Webb John G

    2012-01-01

    BACKGROUND Identifying the optimal fluoroscopic projection of the aortic valve is important for successful transcatheter aortic valve replacement (TAVR). Various imaging modalities including multidetector computed tomography (MDCT) have been proposed for prediction of the optimal deployment projection. We evaluated a method that provides 3 dimensional angiographic reconstructions (3DA) of the aortic root for prediction of the optimal deployment angle and compared it with MDCT. METHODS AND RES...

  13. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  14. An assessment of ninth round; Nona: uma avaliacao da rodada

    Energy Technology Data Exchange (ETDEWEB)

    Assumpcao, Eduardo; Andrade, Leila; Fontana, Raphaela [Agencia Nacional do Petroleo, Gas Natural e Biocombustiveis (ANP), Rio de Janeiro, RJ (Brazil)

    2008-07-01

    Accomplished on November, 27{sup th}, 2007, 271 exploratory blocks were offered in Round 9, distributed within 14 sectors, totalling an area of 73 thousand km{sup 2}. The following basins were included: Campos, Espirito Santo, Para- Maranhao, Parnaiba, Pernambuco-Paraiba, Potiguar, Santos, Reconcavo and Rio do Peixe. From the original lot of 67 companies qualified (31 Brazilian and 36 of foreign origin), 42 offered bids individually or in partnerships. 117 blocks were allocated to 24 winning operator companies. Other 12 enterprises won acreage as non-operator participants of joint bids. A record of R$ 2,1 billion were offered as signature bonuses along with 169.436 units of the so called minimum exploratory programs. These units may be converted to an estimated R$ 1,4 billion. The objective of this paper is to evaluate the results obtained in Round 9, analyzing collected data through three different perspectives of aggregate results: bidding companies, offered areas and exploratory models. (author)

  15. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  16. Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed tomography

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2009-12-01

    Full Text Available "nBackground and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT and computed tomography (CT."nMaterials and Methods: Thermoluminescent dosimeters (TLD were implanted in 14 sites of RANDO phantom to measure average tissue absorbed dose in thyroid gland, parotid glands, submandibular glands, sublingual gland, lenses and buccal skin. The Promax (PLANMECA, Helsinki, Finland unit was selected for Panoramic, conventional linear tomography and cone beam computed tomography examinations and spiral Hispeed/Fxi (General Electric,USA was selected for CT examination. The average tissue absorbed doses were used for the calculation of the equivalent and effective doses in each organ."nResults: The average absorbed dose for Panoramic ranged from 0.038 mGY (Buccal skin to 0.308 mGY (submandibular gland, linear tomography ranged from 0.048 mGY (Lens to 0.510 mGY (submandibular gland,CBCT ranged from 0.322 mGY (thyroid glad to 1.144 mGY (Parotid gland and in CT ranged from 2.495 mGY (sublingual gland to 3.424 mGY (submandibular gland. Total effective dose in CBCT is 5 times greater than Panoramic and 4 times greater than linear tomography, and in CT, 30 and 22 times greater than Panoramic and linear tomography, respectively. Total effective dose in CT is 6 times greater than CBCT."nConclusion: For obtaining 3-dimensional (3D information in maxillofacial region, CBCT delivers the lower dose than CT, and should be preferred over a medical CT imaging. Furthermore, during maxillofacial imaging, salivary glands receive the highest dose of radiation.

  17. OCT structural examination of Madonna dei Fusi by Leonardo da Vinci

    Science.gov (United States)

    Targowski, Piotr; Iwanicka, Magdalena; Sylwestrzak, Marcin; Kaszewska, Ewa A.; Frosinini, Cecilia

    2013-05-01

    Madonna dei Fusi (`Madonna of the Yarnwider') is a spectacular example of Italian Renaissance painting, attributed to Leonardo da Vinci. The aim of this study is to give an account of past restoration procedures. The evidence of a former retouching campaign will be presented with cross-sectional images obtained non-invasively with Optical Coherence Tomography (OCT). Specifically, the locations of overpaintings/retouchings with respect to the original paint layer and secondary varnishes will be given. Additionally, the evidence of a former transfer of the pictorial layer to the new canvas support by detecting the presence of its structure incised into paint layer will be shown.

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  19. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer.

    Science.gov (United States)

    Yang, Zhongyi; Pan, Lingling; Cheng, Jingyi; Hu, Silong; Xu, Junyan; Ye, Dingwei; Zhang, Yingjian

    2012-07-01

    To investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity = 95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. © 2012 The Japanese Urological Association.

  20. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer

    International Nuclear Information System (INIS)

    Yang Zhongyi; Pan Lingling; Cheng Jingyi; Hu Silong; Xu Junyan; Zhang Yingjian; Ye Dingwei

    2012-01-01

    The objective of this study was to investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity=95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. (author)

  1. Digital hilar tomography. Comparison with conventional technique

    International Nuclear Information System (INIS)

    Schaefer, C.B.; Braunschweig, R.; Teufl, F.; Kaiser, W.; Claussen, C.D.

    1993-01-01

    The aim of the following study was to compare conventional hilar tomography and digital hilar tomography. 20 patients were examined both with conventional and digital hilar tomography using the same tomographic technique and the identical exposure dose. All patients underwent computed tomography of the chest as a golden standard. The digital technique, especially the edge-enhanced image version, showed superior image quality. ROC-analysis by 4 readers found equal diagnostic performance without any statistical difference. Digital hilar tomography shows a superior and constant image quality and lowers the rate of re-exposure. Therefore, digital hilar tomography is the preferable method. (orig.) [de

  2. Severe bronchiectasis in a dog: tomographic evaluation; Severa bronquiectasia em um cao: avaliacao tomografica

    Energy Technology Data Exchange (ETDEWEB)

    Babicsak, Viviam Rocco; Campos, Lidice Araujo; Belotta, Alexandra Frey; Oliveira, Hugo Salvador de; Inamassu, Leticia Rocha; Charlier, Murilo Gomes de Soutello; Mamprim, Maria Jaqueline; Vulcano, Luiz Carlos, E-mail: viviam.babicsak@gmail.com [Universidade Estadual Paulista Julio de Mesquita Filho (FMVZ/UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Reproducao Animal e Radiologia Veterinaria

    2012-07-01

    Bronchiectasis is a bronchial dilatation caused by changes in the bronchial wall usually due to infectious processes. Computed tomography is an important imaging modality for the evaluation of this alteration due to its high sensitivity. In this study we describe the case report of a 6-year-old female mixed breed dog with severe and generalized bronchiectasis on computed tomography. Due to the severe extent of bronchiectasis, the method of measurement of the adjacent pulmonary artery and its relationship to the bronchus did not have to be performed. An indirect sign of bronchiectasis identified in the patient was the bronchial wall thickening, possibly due to the infiltration of inflammatory components, edema and even by peri-bronchial abscesses. (author)

  3. Tomography of nonclassical states

    NARCIS (Netherlands)

    Bazrafkan, MR; Man'ko, [No Value

    2003-01-01

    A review of the symplectic tomography method is presented. Superpositions of different types of photon states are considered within the framework of the tomography approach. Such nonclassical photon states as even and odd coherent states, crystallized Schrodinger cat states, and other superposition

  4. Sarcoma de Kaposi relacionado à síndrome da imunodeficiência adquirida: características do comprometimento hepático na tomografia computadorizada e na ressonância magnética Kaposi sarcoma related to acquired immunodeficiency syndrome: hepatic findings on computed tomography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Daniel Nobrega da Costa

    2008-04-01

    Full Text Available Sarcoma de Kaposi é uma neoplasia associada a condições de imunossupressão que acomete os vasos linfáticos e sanguíneos. É a neoplasia intra-hepática mais comum na síndrome da imunodeficiência adquirida. A tomografia computadorizada e a ressonância magnética revelam múltiplos pequenos nódulos, proeminência e realce dos planos periportais, devido à presença de tecido neoplásico. Os autores descrevem um caso de paciente masculino, de 47 anos de idade, com síndrome da imunodeficiência adquirida e sarcoma de Kaposi disseminado.Kaposi sarcoma is a neoplasm associated with immunosuppressive conditions, and involving blood and lymphatic vessels. It is the most frequent intrahepatic neoplasm in patients with acquired immunodeficiency syndrome. Computed tomography and magnetic resonance imaging demonstrate multiple small nodules, prominence and contrast-enhancement of periportal branches due to the presence of the neoplastic tissue. The authors report a case of a 47-year-old male patient with acquired immunodeficiency syndrome presenting disseminated Kaposi sarcoma.

  5. A utilização da teoria da aprendizagem significativa no ensino da Enfermagem

    OpenAIRE

    Alana Tamar Oliveira de Sousa; Nilton Soares Formiga; Simone Helena dos Santos Oliveira; Marta Miriam Lopes Costa; Maria Júlia Guimarães Oliveira Soares

    2015-01-01

    RESUMO Objetivo: sintetizar a produção científica acerca da Teoria da Aprendizagem Significativa no processo de ensino-aprendizagem em Enfermagem. Método: revisão integrativa realizada nas bases de dados MEDLINE, LILACS, SciELO, BDENF e CINAHL, com artigos que abordaram a temática ou aspectos da teoria da aprendizagem significativa de David Ausubel. Fizeram parte da amostra dez artigos, sendo seis escritos no idioma português e quatro no inglês, publicados de 1998 a 2013. Resultados: cinco...

  6. ¹⁸F-fluorodeoxyglucose positron emission tomography-computed tomography for the evaluation of bone metastasis in patients with gastric cancer.

    Science.gov (United States)

    Ma, Dae Won; Kim, Jie-Hyun; Jeon, Tae Joo; Lee, Yong Chan; Yun, Mijin; Youn, Young Hoon; Park, Hyojin; Lee, Sang In

    2013-09-01

    The roles of positron emission tomography and bone scanning in identifying bone metastasis in gastric cancer are unclear. We compared the usefulness of positron emission tomography-computed tomography and scanning in detecting bone metastasis in gastric cancer. Data from 1485 patients diagnosed with gastric cancer who had undergone positron emission tomography-computed tomography and scanning were reviewed. Of 170 enrolled patients who were suspected of bone metastasis in either positron emission tomography or scanning, 81.2% were confirmed to have bone metastasis. The sensitivity, specificity, and accuracy were 93.5%, 25.0%, and 80.6%, respectively, for positron emission tomography and 93.5%, 37.5%, and 82.9%, respectively, for scanning. 87.7% of patients with bone metastasis showed positive findings on two modalities. 15.0% of solitary bone metastases were positive on positron emission tomography only. Positron emission tomography was superior to scanning for the detection of synchronous bone metastasis, but the two modalities were similar for the detection of metachronous bone metastasis. The concordance rate of response assessment after treatment between two modalities was moderate. Positron emission tomography-computed tomography may be more effective for the diagnosis of bone metastasis in the initial staging workup. Conversely, bone scanning and positron emission tomography-computed tomography may be similarly effective for the detection of metachronous bone metastasis. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  7. Publicidade e ética: um estudo da construção da imagem da mulher

    Directory of Open Access Journals (Sweden)

    Elizabeth Moraes Gonçalves

    2010-02-01

    Full Text Available O texto propõe uma reflexão sobre a ética da responsabilidade na publicidade veiculada nas revistas Claudia e Nova. Trata-se de uma pesquisa descritiva, resultante da leitura dos anúncios selecionados, subsidiada por teóricos da Análise do Discurso da linha francesa, que busca averiguar como a mulher é representada. Constatou-se que no contexto da sociedade contemporânea o retrato da mulher como sedutora ainda está presente, mesmo que em vários momentos ela apareça como protagonista de sua própria vida.

  8. Quantification in emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-11-01

    The objective of this lecture is to understand the possibilities and limitations of the quantitative analysis of single photon emission computed tomography (SPECT) and positron emission tomography (PET) images. It is also to identify the conditions to be fulfilled to obtain reliable quantitative measurements from images. Content: 1 - Introduction: Quantification in emission tomography - definition and challenges; quantification biasing phenomena 2 - Main problems impacting quantification in PET and SPECT: problems, consequences, correction methods, results (Attenuation, scattering, partial volume effect, movement, un-stationary spatial resolution in SPECT, fortuitous coincidences in PET, standardisation in PET); 3 - Synthesis: accessible efficiency, know-how, Precautions, beyond the activity measurement

  9. Tomography

    International Nuclear Information System (INIS)

    Allan, C.J.; Keller, N.A.; Lupton, L.R.; Taylor, T.; Tonner, P.D.

    1984-10-01

    Tomography is a non-intrusive imaging technique being developed at CRNL as an industrial tool for generating quantitative cross-sectional density maps of objects. Of most interest is tomography's ability to: distinguish features within complex geometries where other NDT techniques fail because of the complexity of the geometry; detect/locate small density changes/defects within objects, e.g. void fraction measurements within thick-walled vessels, shrink cavities in castings, etc.; provide quantitative data that can be used in analyses, e.g. of complex processes, or fracture mechanics; and provide objective quantitative data that can be used for (computer-based) quality assurance decisions, thereby reducing and in some cases eliminating the present subjectivity often encountered in NDT. The CRNL program is reviewed and examples are presented to illustrate the potential and the limitations of the technology

  10. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using 18 F-fluorodeoxyglucose positron emission tomography-computed tomography

    International Nuclear Information System (INIS)

    Kimizuka, Yoshifumi; Hasegawa, Naoki; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko

    2013-01-01

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess

  11. The value of positron emission tomography/computed tomography for evaluating metastatic disease in patients with pancreatic cancer.

    Science.gov (United States)

    Kim, Mi-Jin; Lee, Kwang Hyuck; Lee, Kyu Taek; Lee, Jong Kyun; Ku, Bon-Ho; Oh, Cho-Rong; Heo, Jin Seok; Choi, Seong-Ho; Choi, Dong Wook

    2012-08-01

    Routine application of positron emission tomography/computed tomography (PET/CT) for pancreatic cancer staging remains a controversial approach. The purpose of this study was to reassess the clinical impact of PET/CT for the detection of distant metastasis of pancreatic cancer. From January 2006 to June 2009, 125 patients with histologically proven pancreatic cancer that had undergone PET/CT at our hospital were retrospectively reviewed. To evaluate the clinical efficacy of PET/CT on the management plan, the post-PET/CT management plans were compared with the pre-PET/CT management plans. After the conventional staging workup, we determined that 76 patients (60.8%) had resectable lesions, whereas 48 patients had unresectable lesions. One patient underwent explorative laparotomy due to equivocal resectability. Positron emission tomography/computed tomography diagnosed distant metastasis in only 2 (2.6%) of the 76 patients with resectable lesions, and these patients did not undergo unnecessary surgical treatment. Complete resection was not performed in 8 of the 74 operative patients because they had distant metastasis detected during the operative procedure. Positron emission tomography/computed tomography diagnosed distant metastasis in 32 of the 44 patients with metastatic lesions that were histologically shown to have sensitivity of 72.7%. Positron emission tomography/computed tomography has a limited role in the evaluation of metastatic disease from pancreatic cancer.

  12. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography; Diagnostico da esteatose hepatica pela tomografia computadorizada de abdome com meio de contraste intravenoso

    Energy Technology Data Exchange (ETDEWEB)

    Monjardim, Rodrigo da Fonseca; Costa, Danilo Manuel Cerqueira; Romano, Ricardo Francisco Tavares; Salvadori, Priscila Silveira; Santos, Jaime de Vargas Conde dos; Atzingen, Augusto Castelli Von; Shigueoka, David Carlos; D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Universidade Federal de Sao Paulo (EPM/UNIFESP), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem

    2013-05-15

    Objective: to evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and methods: in the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 Multiplication-Sign (0.75 Multiplication-Sign P + 0.25 Multiplication-Sign A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results: the simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion: The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity. (author)

  13. Arquitetura da paisagem da cidade e a importância da sistematização da análise do problema projetual

    Directory of Open Access Journals (Sweden)

    Rodrigo Gonçalves dos Santos

    2007-12-01

    Full Text Available Com este artigo pretende-se levantar os conceitos próprios da atividade da Arquitetura Paisagística encarando-a como disciplina projetual e associando-a ao Design Ambiental, necessitando, assim, de linhas metodológicas específicas para apresentação de soluções coerentes aos problemas paisagísticos. Sob esta ótica, reflexões sobre o uso da vegetação no projeto dos espaços exteriores são apresentadas apontando-se uma etapa de sistematização da análise do problema de projeto, dentro da abordagem da concepção de uma metodologia projetual em arquitetura paisagística. Também foram analisadas oito vias de circulação da área central de Florianópolis, Santa Catarina, Brasil, exemplificando uma etapa de sistematização da análise do problema de projeto.

  14. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Harris, L.D.; Ritman, E.L.; Robb, R.A.

    1987-01-01

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  15. Positron emission tomography

    International Nuclear Information System (INIS)

    Dvorak, O.

    1989-01-01

    The principle is briefly described of positron emission tomography, and its benefits and constraints are listed. It is emphasized that positron emission tomography (PET) provides valuable information on metabolic changes in the organism that are otherwise only very difficult to obtain, such as brain diagnosis including relationships between mental disorders and the physiology and pathophysiology of the brain. A PET machine is to be installed in Czechoslovakia in the near future. (L.O.)

  16. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  17. Fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of residual intramuscular myxoma

    International Nuclear Information System (INIS)

    Zade, Anand; Ahire, Archana; Shetty, Shishir; Rai, Sujith; Bokka, Rajashekharrao; Velumani, Arokiaswamy; Kabnurkar, Rasika

    2015-01-01

    Intramuscular myxoma (IM) is a rare benign neoplasm. In a patient diagnosed with IM of left thigh, we report the utility of a postoperative fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography scan in assessing the efficacy of surgical excision

  18. Resistivity tomography-basic concepts and its application. Hiteiko tomography no kiso to oyo

    Energy Technology Data Exchange (ETDEWEB)

    Shima, H

    1990-12-31

    In this paper, principles and characteristics of resistivity tomography are outlined, and its application examples are described. Resistivity tomography is a technology to measure electric potential of many electrodes placed on the earth {prime} s surface or in the well and to analyze the resistivity distribution in the objective area. Arrangement of electrodes (current electrodes and potential electrodes) is determined taking account of the sensitivity distribution. Also, measurements need to be done not only between the surface and a borehole and between boreholes, but also along the wall of a borehole. After the measured data are corrected according to the influence of topography, the initial model is revised repeatedly with the Alpha Center method, and then, resistivity distribution maps are obtained. As an example of field application of resistivity tomography, a geological survey using three boreholes at the scheduled construction site for a dam is described. In this survey, distribution conditions of surface soil, gravel, and andesite were confirmed, and the results almost agreed with the results of seismic tomography. Moreover, another survey with resistivity tomography was carried out at the test site of hot dry rock power generation in Yamagata Prefecture. There, conductive solution was injected from the borehole after hydraulic fracturing, and cracking conditions of rocks were investigated. 28 refs., 21 figs., 1 tab.

  19. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using (18) F-fluorodeoxyglucose positron emission tomography-computed tomography.

    Science.gov (United States)

    Kimizuka, Yoshifumi; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko; Hasegawa, Naoki

    2013-11-14

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess.

  20. Measuring Weld Profiles By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Noncontacting, nondestructive computer tomography system determines internal and external contours of welded objects. System makes it unnecessary to take metallurgical sections (destructive technique) or to take silicone impressions of hidden surfaces (technique that contaminates) to inspect them. Measurements of contours via tomography performed 10 times as fast as measurements via impression molds, and tomography does not contaminate inspected parts.

  1. A utilização da teoria da aprendizagem significativa no ensino da Enfermagem

    Directory of Open Access Journals (Sweden)

    Alana Tamar Oliveira de Sousa

    2015-08-01

    Full Text Available RESUMOObjetivo:sintetizar a produção científica acerca da Teoria da Aprendizagem Significativa no processo de ensino-aprendizagem em Enfermagem.Método:revisão integrativa realizada nas bases de dados MEDLINE, LILACS, SciELO, BDENF e CINAHL, com artigos que abordaram a temática ou aspectos da teoria da aprendizagem significativa de David Ausubel. Fizeram parte da amostra dez artigos, sendo seis escritos no idioma português e quatro no inglês, publicados de 1998 a 2013.Resultados:cinco artigos fizeram alusão à Teoria da Aprendizagem Significativa, quatro citaram Ausubel como autor dessa teoria e apenas dois seguiram a estrutura para a aplicação da teoria completamente. Há escassez de estudos sobre o tema e os que o abordam não o correlacionam com a teoria de Ausubel.Conclusão:faz-se necessário romper com a dicotomia entre teoria e prática e promover a articulação dos conteúdos com a ação, introduzindo o aluno como autor de seu próprio conhecimento.

  2. Positron emission tomography/computed tomography surveillance in patients with Hodgkin lymphoma in first remission has a low positive predictive value and high costs.

    Science.gov (United States)

    El-Galaly, Tarec Christoffer; Mylam, Karen Juul; Brown, Peter; Specht, Lena; Christiansen, Ilse; Munksgaard, Lars; Johnsen, Hans Erik; Loft, Annika; Bukh, Anne; Iyer, Victor; Nielsen, Anne Lerberg; Hutchings, Martin

    2012-06-01

    The value of performing post-therapy routine surveillance imaging in patients with Hodgkin lymphoma is controversial. This study evaluates the utility of positron emission tomography/computed tomography using 2-[18F]fluoro-2-deoxyglucose for this purpose and in situations with suspected lymphoma relapse. We conducted a multicenter retrospective study. Patients with newly diagnosed Hodgkin lymphoma achieving at least a partial remission on first-line therapy were eligible if they received positron emission tomography/computed tomography surveillance during follow-up. Two types of imaging surveillance were analyzed: "routine" when patients showed no signs of relapse at referral to positron emission tomography/computed tomography, and "clinically indicated" when recurrence was suspected. A total of 211 routine and 88 clinically indicated positron emission tomography/computed tomography studies were performed in 161 patients. In ten of 22 patients with recurrence of Hodgkin lymphoma, routine imaging surveillance was the primary tool for the diagnosis of the relapse. Extranodal disease, interim positron emission tomography-positive lesions and positron emission tomography activity at response evaluation were all associated with a positron emission tomography/computed tomography-diagnosed preclinical relapse. The true positive rates of routine and clinically indicated imaging were 5% and 13%, respectively (P = 0.02). The overall positive predictive value and negative predictive value of positron emission tomography/computed tomography were 28% and 100%, respectively. The estimated cost per routine imaging diagnosed relapse was US$ 50,778. Negative positron emission tomography/computed tomography reliably rules out a relapse. The high false positive rate is, however, an important limitation and a confirmatory biopsy is mandatory for the diagnosis of a relapse. With no proven survival benefit for patients with a pre-clinically diagnosed relapse, the high costs and low

  3. Diffuse nesidioblastosis diagnosed on a Ga-68 DOTATATE positron emission tomography/computerized tomography

    International Nuclear Information System (INIS)

    Arun, Sasikumar; Mittal, Bhagwant Rai; Shukla, Jaya; Bhattacharya, Anish; Kumar, Praveen

    2013-01-01

    The authors describe a 50 days old pre-term infant with persistent hyperinsulinemic hypoglycemia of infancy in whom 68 Ga DOTATATE positron emission tomography/computerized tomography scan showed diffusely increased tracer uptake in the entire pancreas with no abnormal tracer uptake anywhere else in the body, suggestive of a diffuse variant of nesidioblastosis. (author)

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  5. Positron emission tomography (PET) imaging of nicotine-induced dopamine release in squirrel monkeys using [18F]Fallypride.

    Science.gov (United States)

    Naylor, Jennifer E; Hiranita, Takato; Matazel, Katelin S; Zhang, Xuan; Paule, Merle G; Goodwin, Amy K

    2017-10-01

    Nicotine, the principal psychoactive tobacco constituent, is thought to produce its reinforcing effects via actions within the mesolimbic dopamine (DA) system. The objective of the current study was to examine the effect of nicotine on DA D 2 /D 3 receptor availability in the nonhuman primate brain with the use of the radioligand [ 18 F]fallypride and positron emission tomography (PET). Ten adult male squirrel monkeys were used in the current study. Each subject underwent two PET scans, one with an injection (IV) of saline and subsequently one with an injection of nicotine (0.032mg/kg). The DA D 2 /D 3 antagonist, [ 18 F]fallypride, was delivered IV at the beginning of each scan, and nicotine or saline was delivered at 45min into the scan. Regions of interest (ROI) were drawn on specific brain regions and these were used to quantify standard uptake values (SUVs). The SUV is defined as the average concentration of radioactivity in the ROI x body weight/injected dose. Using the cerebellum as a reference region, SUV ratios (SUV ROI /SUV cerebellum ) were calculated to compare saline and nicotine effects in each ROI. Two-way repeated ANOVA revealed a significant decrease of SUV ratios in both striatal and extrastriatal regions following an injection of nicotine during the PET scans. Like other drugs of abuse, these results indicate that nicotine administration may produce DA release, as suggested by the decrease in [ 18 F]fallypride signal in striatal regions. These findings from a nonhuman primate model provide further evidence that the mesolimbic DA system is affected by the use of products that contain nicotine. Published by Elsevier B.V.

  6. Batch Computed Tomography Analysis of Projectiles

    Science.gov (United States)

    2016-05-01

    ARL-TR-7681 ● MAY 2016 US Army Research Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt, Chris M...Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt and Matthew S Bratcher Weapons and Materials Research...values to account for projectile variability in the ballistic evaluation of armor. 15. SUBJECT TERMS computed tomography , CT, BS41, projectiles

  7. Gestões do desenvolvimento e desenvolvimentos da gestão: da unilateralidade reificada à dialogicidade da simbiose homem/natureza

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Justen

    Full Text Available Este artigo, ao situar culturalmente os fenômenos da gestão e do desenvolvimento, em sua concepção tradicional, no projeto da modernidade e ao identificar o predomínio da unilateralidade reificada na interface entre gestão e desenvolvimento - a primeira vista como instrumento técnico submisso à via clássica do segundo - almeja evidenciar as potencialidades da compreensão e da construção de alternativas, tanto para a gestão como para o desenvolvimento, a partir da ressignificação dessa interface. Para tanto, o esforço foi direcionado ao resgate do que é comum aos fenômenos da gestão e do desenvolvimento - os substratos antropológico e ecológico -, nucleados nos princípios da reciprocidade dialógica, concretizadora da condição antropológica, e da finitude, caracterizadora da condição ecológica. Ao final, são apresentadas oito potenciais contribuições advindas da exploração renovada da interface entre a gestão e o desenvolvimento. Propôs-se, ainda, a substituição da lógica instrumental da eficiência financeira, comum à concepção tradicional dos fenômenos estudados, pela lógica da simbiose dialógica homem/natureza, uma vez que, como fenômenos sociais, desenvolvimento e gestão, mediados pelo meio, também são ecológicos em sua essência.

  8. Computed tomography of pulmonary nodules

    International Nuclear Information System (INIS)

    Nakata, Hajime; Honda, Hiroshi; Nakayama, Chikashi; Kimoto, Tatsuya; Nakayama, Takashi

    1983-01-01

    We have evaluated the value of computed tomography (CT) in distinguishing benign and malignant pulmonary nodules. CT was performed on 30 cases of solitary pulmonary nodules consisting of 17 primary lung cancers, 3 metastatic tumors and 10 benign nodules. The CT number was calculated for each lesion. Three benign nodules showed CT numbers well above the range of malignant nodules, and only in one of them was calcification visible on conventional tomography. In 6 benign nodules, the CT numbers overlapped those of malignant lesion and could not be differentiated. Thus the measurement of CT number can be useful to confirm the benign nature of certain nodules when calcification is unclear or not visible on conventional tomography. As for the morphological observation of the nodule, CT was not superior to conventional tomography and its value seems to be limited. (author)

  9. Hybrid Single Photon Emission Computed Tomography/Computed Tomography Sulphur Colloid Scintigraphy in Focal Nodular Hyperplasia

    International Nuclear Information System (INIS)

    Bhoil, Amit; Gayana, Shankramurthy; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2013-01-01

    It is important to differentiate focal nodular hyperplasia (FNH), a benign condition of liver most commonly affecting women, from other neoplasm such as hepatic adenoma and metastasis. The functional reticuloendothelial features of FNH can be demonstrated by scintigraphy. We present a case of breast cancer in whom fluorodeoxyglucose positron emission tomography/computerized tomography (CT) showed a homogenous hyperdense lesion in liver, which on Tc99m sulfur colloid single-photon emission computed tomography/CT was found to have increased focal tracer uptake suggestive of FNH

  10. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  11. Matlab enhanced multi-threaded tomography optimization sequence (MEMTOS)

    International Nuclear Information System (INIS)

    Lum, Edward S.; Pope, Chad L.

    2016-01-01

    Highlights: • Monte Carlo simulation of spent nuclear fuel assembly neutron computed tomography. • Optimized parallel calculations conducted from within the MATLAB environment. • Projection difference technique used to identify anomalies in spent nuclear fuel assemblies. - Abstract: One challenge associated with spent nuclear fuel assemblies is the lack of non-destructive analysis techniques to determine if fuel pins have been removed or replaced or if there are significant defects associated with fuel pins deep within a fuel assembly. Neutron computed tomography is a promising technique for addressing these qualitative issues. Monte Carlo simulation of spent nuclear fuel neutron computed tomography allows inexpensive process investigation and optimization. The main purpose of this work is to provide a fully automated advanced simulation framework for the analysis of spent nuclear fuel inspection using neutron computed tomography. The simulation framework, called Matlab Enhanced Multi-Threaded Tomography Optimization Sequence (MEMTOS) not only automates the simulation process, but also generates superior tomography image results. MEMTOS is written in the MATLAB scripting language and addresses file management, parallel Monte Carlo execution, results extraction, and tomography image generation. This paper describes the mathematical basis for neutron computed tomography, the Monte Carlo technique used to simulate neutron computed tomography, and the overall tomography simulation optimization algorithm. Sequence results presented include overall simulation speed enhancement, tomography and image results obtained for Experimental Breeder Reactor II spent fuel assemblies and light water reactor fuel assemblies. Optimization using a projection difference technique are also described.

  12. O sentido da espiritualidade na transitoriedade da vida

    Directory of Open Access Journals (Sweden)

    Isabel Cristina de Oliveira Arrieira

    Full Text Available Resumo Objetivo: Compreender o sentido da espiritualidade para a pessoa em cuidados paliativos. Métodos: Abordagem qualitativa, fundamentada na fenomenologia existencialista e referencial de Viktor Frankl. Os participantes foram nove pessoas em cuidados paliativos atendidas no domicílio. Informações coletadas por meio da observação e de entrevista realizadas no período de junho a outubro de 2014, gravadas, transcritas e transformadas em texto interpretado com a abordagem fenomenológica hermenêutica. Resultados: Surgiram as seguintes categorias: sentido de continuidade da vida; sentido de alívio do sofrimento; sentido de naturalidade da morte e sentido de valorização do viver. Conclusão: Para a integralidade da atenção faz-se necessário a inclusão da espiritualidade na prática do cuidado em saúde. A espiritualidade proporciona o encontro existencial entre a pessoa em cuidados paliativos e os profissionais que a cuidam em sua integralidade.

  13. Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Mogensen, Mette; Themstrup, Lotte; Banzhaf, Christina

    2014-01-01

    Optical coherence tomography (OCT) has developed rapidly since its first realisation in medicine and is currently an emerging technology in the diagnosis of skin disease. OCT is an interferometric technique that detects reflected and backscattered light from tissue and is often described as the o......Optical coherence tomography (OCT) has developed rapidly since its first realisation in medicine and is currently an emerging technology in the diagnosis of skin disease. OCT is an interferometric technique that detects reflected and backscattered light from tissue and is often described...

  14. Densitometria da vértebra dorsal, osso pleural e osso neural em tartarugas verdes hígidas por tomografia computadorizada quantitativa Densitometry of dorsal vertebrae, pleural bone and neural bone in healthy green sea turtles by quantitative computed tomography

    Directory of Open Access Journals (Sweden)

    Jannine Forattini de Oliveira

    2012-08-01

    Full Text Available A tomografia computadorizada quantitativa (TCQ é uma técnica com alta sensibilidade, aplicabilidade e precisão no diagnóstico de perda de massa óssea, entretanto a falta de valores de normalidade para animais silvestres limita a sua aplicação clínica. O presente estudo objetiva estabelecer valores médios de radiodensidade do osso trabecular das vértebras dorsais, osso pleural e osso neural de tartarugas marinhas juvenis hígidas utilizando a TCQ. Para isso, utilizou-se um grupo experimental de cinco animais que foram submetidos a exames de tomografia computadorizada helicoidal, sendo as mensurações da radiodensidade óssea realizadas ao nível da terceira, quarta e quinta vértebras dorsais. Os valores médios de radiodensidade do osso trabecular das vértebras dorsais, osso pleural e osso neural foram, respectivamente, de 287,4±39,1, 1093,74±100,4 e 1089,6±86,5 unidades Hounsfield (HU. Estudos complementares devem ser realizados em diferentes espécies e faixas etárias de quelônios para favorecer a aplicação clínica desta técnica.Quantitative computed tomography (QCT is a technique with high sensitivity, applicability and accuracy in the diagnosis of bone loss; however the lack of normal values for wild animals limits their clinical application. This study aims to establish medium values radiodensity trabecular bone of the dorsal vertebrae, bone pleural and neural bone in healthy juvenile sea turtles using the QTC. For this we used an experimental group of five animals that underwent helical computed tomography, and measurements of bone radiodensity conducted at the level of the third, fourth and fifth dorsal vertebrae. The medium values of radiodensity trabecular bone of the dorsal vertebrae, pleural bone, and neural bone were respectively 287.4±39.1, 1093.74±100.4, and 1089.6±86.5 Hounsfield units (HU. Further studies should be performed in different species and ages of turtles to encourage the clinical application of

  15. Image quality and volume computed tomography air kerma index (C{sub vol}) evaluation in Recife; Avaliacao da qualidade de imagem e do indice volumetrico de Kerma ar em tomografia computadorizada (C{sub vol}) em Recife

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Marcos Ely Almeida

    2008-07-01

    The Computed Tomography (CT) is an important diagnostic imaging method, widely used. However, in spite of all the advantages and technologic advances within the CT scanners, the tomographic procedures result in high absorbed doses to patients. The main objective of this work was to perform a dosimetric study of CT scanners located at Recife and to evaluate the image quality on CT examinations in these equipment. The volume CT air kerma index (C{sub VOL}) and air kerma length product (P{sub KL,CT}) were estimated. These values were calculated using normalized weighted air kerma indexes in CT standard dosimetry phantoms ({sub n}C{sub W}), supplied by ImPACT group for several CT scanners, and the scan parameters of routine head, routine chest and hi-resolution chest CT exams performed at 20 institutions. The irradiation parameters of 15 adult patients for each CT procedure were registered at six participating centres, at which the phantom from the American College of Radiology (ACR) CT accreditation protocol was used for the image quality measurements. For routine head exams, the C{sub VOL} values varied between 12 and 58 mGy (at the posterior fossa) and 15 to 58 mGy (at the cerebrum) and the P{sub KL,CT}, from 150 to 750 mGy{center_dot}cm. The C{sub VOL} values for routine chest procedures varied from 3 to 26 mGy and the P{sub KL,CT}, between 120 and 460 mGy{center_dot}cm. In relation to Hi-resolution chest exams, C{sub VOL} values were from 1.0 to 2.7 mGy and the P{sub KL,CT} values varied between 24 and 67 mGy{center_dot}cm. The image quality evaluations results showed that almost all scanners presented at least one inadequacy. One of the equipment presented faults at 70% of the tests. With regard to the image noise, only two scanners presented acceptable results. From these results, it is possible to conclude that the volume CT air kerma index values are lower than the European reference levels. However, the image quality of these CT scanners does not attend the

  16. Processos da construção da Política Nacional de Promoção da Saúde

    Directory of Open Access Journals (Sweden)

    João Leite Ferreira Neto

    2013-10-01

    Full Text Available Investigou-se os processos de construção da Política Nacional de Promoção da Saúde (PNPS, pela análise de três documentos produzidos pelo Ministério da Saúde entre 2002 e 2005 e do texto final da PNPS. Foram entrevistados cinco sujeitos que participaram da construção da PNPS, dos quais três eram gestores do Ministério da Saúde e dois pesquisadores. Os documentos foram explorados com a Análise do Discurso. O artigo contribui para aprofundar os debates sobre o processo de construção da PNPS. A promoção da saúde revelou seus antagonismos, o que motivou a demora de sua aprovação final. A indução internacional via financiamento demonstrou ser o elemento crucial para a definição da forma final da PNPS, trazendo de volta a criticada ênfase na mudança de estilos de vida em suas "Ações". Destaca-se o processo de produção negociada de consenso, que culminou com a criação do Comitê Gestor da PNPS, com a participação de diversos subsetores, estrutura inovadora no Ministério da Saúde.

  17. X-ray Compton line scan tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kupsch, Andreas; Lange, Axel; Jaenisch, Gerd-Ruediger [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany). Fachgruppe 8.5 - Mikro-ZfP; Hentschel, Manfred P. [Technische Univ. Berlin (Germany); Kardjilov, Nikolay; Markoetter, Henning; Hilger, Andre; Manke, Ingo [Helmholtz-Zentrum Berlin (HZB) (Germany); Toetzke, Christian [Potsdam Univ. (Germany)

    2015-07-01

    The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.

  18. 18 F-fluorodeoxyglucose positron emission tomography-computed tomography for preoperative lymph node staging in patients undergoing radical cystectomy for bladder cancer: a prospective study.

    Science.gov (United States)

    Hitier-Berthault, Maryam; Ansquer, Catherine; Branchereau, Julien; Renaudin, Karine; Bodere, Françoise; Bouchot, Olivier; Rigaud, Jérôme

    2013-08-01

    The objective of our study was to analyze the diagnostic performance of (18) F-fluorodeoxyglucose positron emission tomography-computed tomography for lymph node staging in patients with bladder cancer before radical cystectomy and to compare it with that of computed tomography. A total of 52 patients operated on between 2005 and 2010 were prospectively included in this prospective, mono-institutional, open, non-randomized pilot study. Patients who had received neoadjuvant chemotherapy or radiotherapy were excluded. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography in addition to computed tomography was carried out for lymph node staging of bladder cancer before radical cystectomy. Lymph node dissection during radical cystectomy was carried out. Findings from (18) F-fluorodeoxyglucose positron emission tomography-computed tomography and computed tomography were compared with the results of definitive histological examination of the lymph node dissection. The diagnostic performance of the two imaging modalities was assessed and compared. The mean number of lymph nodes removed during lymph node dissection was 16.5 ± 10.9. Lymph node metastasis was confirmed on histological examination in 22 cases (42.3%). This had been suspected in five cases (9.6%) on computed tomography and in 12 cases (23.1%) on (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. Sensitivity, specificity, positive predictive value, negative predictive value, relative risk and accuracy were 9.1%, 90%, 40%, 57.4%, 0.91 and 55.7%, respectively, for computed tomography, and 36.4%, 86.7%, 66.7%, 65%, 2.72, 65.4%, respectively, for (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography is more reliable than computed tomography for preoperative lymph node staging in patients with invasive bladder carcinoma undergoing radical cystectomy. © 2012 The Japanese

  19. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  20. The value of computed tomography in ''sciatica''

    International Nuclear Information System (INIS)

    Boehm-Jurkovic, H.; Hammer, B.

    1981-01-01

    13 cases of therapy-resistant lumboischialgia without herniated disk, caused in 12 cases by a tumour and in 1 case by an abscess, were examined by computed tomography of the lumbar and pelvic region. This method is indicated immediately after insufficient results of conventional X-ray methods (including tomography) and of lumbosacral radiculography. The computed tomography is indispensable also in patients with ''sciatica'' with a known malignoma. The information given by computed tomography is essential for the therapy planning. (author)

  1. Teoria da adequação econômica da conduta: significado econômico da conduta em face da tutela penal antitruste

    OpenAIRE

    Luiz da Silva, Ivan

    2009-01-01

    Essa tese tem por objetivo o desenvolvimento da teoria da adequação econômica da conduta no direito penal econômico. Vale-se de uma abordagem interdisciplinar abrangendo a Economia, o direito econômico e o direito penal. Para alcançar o desiderato a investigação analisou a intervenção do direito penal em face da atividade econômica e, em especial, os fundamentos da tutela penal antitruste, para fins de estabelecer os contornos teóricos necessários à aplicação das premissas fund...

  2. Use of Computed Tomography and Positron Emission Tomography/Computed Tomography for Staging of Local Extent in Patients With Malignant Pleural Mesothelioma

    OpenAIRE

    Frauenfelder, Thomas; Kestenholz, Peter; Hunziker, Roger; Nguyen, Thi Dan Linh; Fries, Martina; Veit-Haibach, Patrick; Husmann, Lars; Stahel, Rolf; Weder, Walter; Opitz, Isabelle

    2015-01-01

    PURPOSE The objective of this study was to determine the diagnostic value of computed tomography (CT) and positron emission tomography (PET)/CT for staging of malignant pleural mesothelioma (MPM) in patients undergoing induction chemotherapy. METHODS Sixty-two patients (median age, 61 years; female: n = 9) with proven MPM underwent CT after induction chemotherapy. Of these, 28 underwent additional PET/CT. Extrapleural pneumonectomy was performed for pathological TNM staging. Clinical TNM s...

  3. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  4. Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

    NARCIS (Netherlands)

    Piers, LH; Dorgelo, J; Tio, RA; Jessurun, GAJ; Oudkerk, M; Zijlstra, F

    This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic

  5. Ocorrência da ferrugem da videira em Minas Gerais

    Directory of Open Access Journals (Sweden)

    Adelica Aparecida Xavier

    2012-03-01

    Full Text Available A ferrugem da videira causada por Phakopsora euvitis Ono constitui-se numa ameaça às regiões produtoras de uva em função do potencial destrutivo da planta. A doença foi detectada no Brasil, pela primeira vez, em 2001. Atualmente, ela ocorre no Paraná, Mato Grosso do Sul, São Paulo, Rio Grande do Sul, Mato Grosso, Roraima, Espírito Santo e Santa Catarina. Em abril de 2010, observaram-se na estação experimental da Unimontes, Janaúba, Minas Gerais, plantas da cv. Niágara rosada com sintomas típicos da doença. A análise dos sintomas e a caracterização dos urediniósporos sésseis, levemente equinulados, com formato oval, ou elipsoide formado em urédias subepidérmicas na origem, inrompentes e com paráfises circundantes dorsalmente, levaram à diagnose de Phakopsora euvitis como o agente causal da doença. Este é o primeiro relato da doença no Estado de Minas Gerais.

  6. 21 CFR 892.1310 - Nuclear tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nuclear tomography system. 892.1310 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1310 Nuclear tomography system. (a) Identification. A nuclear tomography system is a device intended to detect nuclear radiation in the body and...

  7. A CPMI da Violência Contra a Mulher e a Implementação da Lei Maria Da Penha

    Directory of Open Access Journals (Sweden)

    Carmen Hein de Campos

    2015-05-01

    Full Text Available Este artigo analisa as conclusões da Comissão Parlamentar Mista de Inquérito da Violência contra a Mulher, criada pelo Congresso Nacional Brasileiro em 2012, no que tange à aplicação da Lei Maria da Penha. Após um ano e meio de trabalho, o relatório da CPMI apontou a fragilidade das políticas públicas de enfrentamento à violência contra mulheres e os obstáculos na implementação da Lei Maria da Penha, dentre os quais, destacam-se: a precariedade da rede de serviços e o reduzido número de juizados especializados em atendimento às mulheres em situação de violência doméstica e familiar; o descumprimento da decisão do Supremo Tribunal Federal que proíbe a aplicação da suspensão condicional do processo; a resistência de operadores/as do direito em entender a proposta da nova lei e romper com a lógica familista e o insuficiente orçamento para o desenvolvimento e a manutenção das políticas públicas de enfrentamento a essas situações de violência. A análise do relatório da CPMI permite concluir que os estados brasileiros investem muito pouco em políticas públicas específicas e que a implementação integral da Lei Maria da Penha depende de uma nova compreensão jurídica, da articulação entre os poderes públicos e de uma política orçamentária de gênero.

  8. single photon emission tomography and positron emission tomography - Part 1 (October 2012), Part 2 (October 2010)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2010-10-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) and the positron emission tomography (PET) imaging techniques. Part 1 Content: 1 - Introduction: anatomic, functional and molecular imaging; 2 - Radiotracers: chemical and physical constraints, gamma photon emitters, positon emitters, radioisotopes production, emitters type and imaging techniques; 3 - Gamma cameras; 4 - Quantification in emission tomography: attenuation, scattering, un-stationary spatial resolution; 5 - Synthesis and conclusion. Part 2 content: 1 - Positon emitters; 2 - Positons detection: Coincidence detection (electronic collimation, PET detectors with gamma cameras, dedicated PET detectors, spectrometry); PET detectors type; time-of-flight PET; 2D PET; 3D PET; 3 - Quantification in emission tomography: detected events, attenuation, scattering, fortuitous coincidences, standardisation; 4 - Common SPECT and PET problems: partial volume effect, movement, tomographic reconstruction, calibration, dead time; 5 - Synthesis and conclusion

  9. 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Tuberculosis: Spectrum of Manifestations.

    Science.gov (United States)

    Agarwal, Krishan Kant; Behera, Abhishek; Kumar, Rakesh; Bal, Chandrasekhar

    2017-01-01

    The objective of this article is to provide an illustrative tutorial highlighting the utility of 18 F-fluorodeoxyglucose-positron emission tomography/computed tomography ( 18 F-FDG-PET/CT) imaging to detect spectrum of manifestations in patients with tuberculosis (TB). FDG-PET/CT is a powerful tool for early diagnosis, measuring the extent of disease (staging), and consequently for evaluation of response to therapy in patients with TB.

  10. Corticostriatal and Dopaminergic Response to Beer Flavor with Both fMRI and [(11) C]raclopride Positron Emission Tomography.

    Science.gov (United States)

    Oberlin, Brandon G; Dzemidzic, Mario; Harezlak, Jaroslaw; Kudela, Maria A; Tran, Stella M; Soeurt, Christina M; Yoder, Karmen K; Kareken, David A

    2016-09-01

    Cue-evoked drug-seeking behavior likely depends on interactions between frontal activity and ventral striatal (VST) dopamine (DA) transmission. Using [(11) C]raclopride (RAC) positron emission tomography (PET), we previously demonstrated that beer flavor (absent intoxication) elicited VST DA release in beer drinkers, inferred by RAC displacement. Here, a subset of subjects from this previous RAC-PET study underwent a similar paradigm during functional magnetic resonance imaging (fMRI) to test how orbitofrontal cortex (OFC) and VST blood oxygenation level-dependent (BOLD) responses to beer flavor are related to VST DA release and motivation to drink. Male beer drinkers (n = 28, age = 24 ± 2, drinks/wk = 16 ± 10) from our previous PET study participated in a similar fMRI paradigm wherein subjects tasted their most frequently consumed brand of beer and Gatorade(®) (appetitive control). We tested for correlations between BOLD activation in fMRI and VST DA responses in PET, and drinking-related variables. Compared to Gatorade, beer flavor increased wanting and desire to drink, and induced BOLD responses in bilateral OFC and right VST. Wanting and desire to drink correlated with both right VST and medial OFC BOLD activation to beer flavor. Like the BOLD findings, beer flavor (relative to Gatorade) again induced right VST DA release in this fMRI subject subset, but there was no correlation between DA release and the magnitude of BOLD responses in frontal regions of interest. Both imaging modalities showed a right-lateralized VST response (BOLD and DA release) to a drug-paired conditioned stimulus, whereas fMRI BOLD responses in the VST and medial OFC also reflected wanting and desire to drink. The data suggest the possibility that responses to drug-paired cues may be rightward biased in the VST (at least in right-handed males) and that VST and OFC responses in this gustatory paradigm reflect stimulus wanting. Copyright © 2016 by the Research Society on

  11. Avaliacao da gestao ambiental dos hoteis de selva na Amazonia, Brasil

    Directory of Open Access Journals (Sweden)

    Gomes de Moraes, Adriana

    2008-10-01

    Full Text Available In the challenge of desvelar of that it forms the hoteleiros enterprises they manage its ambient action without causing great impacts in one of biggest ecosystems of the world, the Amazonian forest, was tried to know in this research the forms of ambient management of the located hotels of forest in the legal Amazônia. The norteadora question of the research was to know that type of ambient management is made by the hotels of selva?Foi used as instrument of collection of data the questionnaire, that if subdividiui in four great subjects to be searched. The first one was relative questions to the planning of the place, according to to the profile of the customer, third to the room and the relative questions architecture the building subject relative questions to the energy resources and infrastructure of the public services. As result of this analysis was concluded that two of three hotels searched are practising management ambient of form less impactante, since type of construction adopted until services offered to guests, or either shows objective that its hotel is coadjuvante for customer that visits this type of place, that stops it does not import luxury, comfort and amenities, more yes contact with the fauna and flora and way of life of the natives.

  12. Imaging assessment of osteitis pubis; Avaliacao por imagem da osteite pubica

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Alexia Abuhid; Ferreira, Ana Paula Alves; Leite, Ana Rachel Albuquerque de Moura; Guido, Daniela Araujo; Rodrigues, Rogeria Nobre [Axial Centro de Imagem, Belo Horizonte, MG (Brazil)]. E-mail: ce@cidbh.com.br; Araujo, Rodrigo Otavio Dias [Minas Tenis Clube, Belo Horizonte, MG (Brazil); Lasmar, Rodrigo Campos Pace [Faculdade de Ciencias Medicas de Minas Gerais, Belo Horizonte, MG (Brazil). Curso de Fisioterapia

    2005-10-15

    Objective: to assess the physiopathological aspects of osteitis pubis and the findings seen on imaging methods, emphasizing the usefulness of Flamingo view radiographs and the diagnostic aspects of Magnetic resonance images. Material and Method: magnetic resonance images of ten patients (eight of them professional athletes) referring symptoms in the inguinal regional were retrospectively evaluated. For some of these patients Flaming view radiographs were performed. Results: in all studied patients magnetic resonance imaging was the only diagnostic method capable of showing the different phases os osteitis pubis, from acute cases with pubic bone marrow edematous changes to chronic cases with involvement of other pelvic joints. Flamingo view radiographs were performed in six patients and three of them were diagnosed with vertical pubis symphyseal instability greater than 2 mm of vertical displacement. This diagnosis was confirmed by instability tests using orthopedic manoeuvres. Conclusion: magnetic resonance imaging was the most helpful method for the diagnosis of different phases of osteitis pubis whereas conventional X-ray was inconclusive in the initial phases. Flamingo view radiographs were extremely important to show vertical instability of the pubic symphysis, which in combination with osteitis pubis can be the cause of failure of nonoperative treatment. (author)

  13. Protean appearance of craniopharyngioma on computed tomography

    International Nuclear Information System (INIS)

    Danziger, A.; Price, H.I.

    1979-01-01

    Craniopharyngiomas present a diverse appearance on computed tomography. Histological diagnosis is not always possible, but computed tomography is of great assistance in the delineation of the tumour as well as of the degree of associated hydrocephalus. Computed tomography also enables rapid non-invasive follow-up after surgery or radiotherapy, or both

  14. A PROBLEMÁTICA DA BIOPIRATARIA: REFLEXÕES A PARTIR DA GEOPOLÍTICA E DOS DIREITOS DA SOCIOBIODIVERSIDADE

    OpenAIRE

    Nunes, Denise Silva; UFSM; Tybusch, Jerônimo Siqueira; UFSM

    2013-01-01

    O bioimperialismo configura-se como uma característica da geopolítica da atualidade, com alicerces nas estruturas da globalização e do capitalismo. Nesse contexto, a problemática da pesquisa consiste na violação dos direitos dos povos locais e a exploração do meio ambiente, em que o atual sistema internacional de propriedade intelectual contribui para a biopirataria dos recursos naturais, por meio da infiltração, em áreas ricas em diversidade biológica, das grandes corporações, multinacionais...

  15. Optimal experiment design for quantum state tomography: Fair, precise, and minimal tomography

    International Nuclear Information System (INIS)

    Nunn, J.; Smith, B. J.; Puentes, G.; Walmsley, I. A.; Lundeen, J. S.

    2010-01-01

    Given an experimental setup and a fixed number of measurements, how should one take data to optimally reconstruct the state of a quantum system? The problem of optimal experiment design (OED) for quantum state tomography was first broached by Kosut et al.[R. Kosut, I. Walmsley, and H. Rabitz, e-print arXiv:quant-ph/0411093 (2004)]. Here we provide efficient numerical algorithms for finding the optimal design, and analytic results for the case of 'minimal tomography'. We also introduce the average OED, which is independent of the state to be reconstructed, and the optimal design for tomography (ODT), which minimizes tomographic bias. Monte Carlo simulations confirm the utility of our results for qubits. Finally, we adapt our approach to deal with constrained techniques such as maximum-likelihood estimation. We find that these are less amenable to optimization than cruder reconstruction methods, such as linear inversion.

  16. Computed tomography and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography findings in adrenal candidiasis and histoplasmosis: two cases.

    Science.gov (United States)

    Altinmakas, Emre; Guo, Ming; Kundu, Uma R; Habra, Mouhammed Amir; Ng, Chaan

    2015-01-01

    We report the contrast-enhanced computed tomography (CT) and (18)F-fluorodeoxyglucose positron emission tomography findings in adrenal histoplasmosis and candidiasis. Both demonstrated bilateral hypermetabolic heterogeneous adrenal masses with limited wash-out on delayed CT. Adrenal candidiasis has not been previously reported, nor have the CT wash-out findings in either infection. The adrenal imaging findings are indistinguishable from malignancy, which is more common; but in this setting, physicians should be alert to the differential diagnosis of fungal infections, since it can be equally deadly. Published by Elsevier Inc.

  17. A dignidade da pessoa humana na doutrina social da igreja

    Directory of Open Access Journals (Sweden)

    Manzone, Gianni

    2010-01-01

    Full Text Available O texto faz uma análise panorâmica sobre a compreensão da dignidade humana nos diversos textos da Doutrina Social da Igreja, mostrando o entendimento da mesma nos diversos documentos dos Papas, notadamente Leão XII, Pio XI, Pio XII e João Paulo II, além de apontar aspectos históricos e culturais que influenciaram cada pronunciamento, o que foi determinante para a evolução do pensamento do Magistério na questão social. O ponto de partida é a visão antropológica da Doutrina Social da Igreja, resumida em termos de “homem criado por Deus a sua imagem e resgatado pelo sangue de Jesus Cristo” (Sollicitudo Rei Socialis 29. A partir daí, há a defesa do primado do ser humano sobre o social e reivindicações totalitaristas que perpassaram a história recente da humanidade, embora a pessoa seja sempre um ser-em-relação e situado em uma sociedade determinada

  18. Use of an improved simultaneous tomography cassette in linear tomography

    International Nuclear Information System (INIS)

    Egender, G.; Pirker, E.; Gornik, E.; Innsbruck Univ.

    1984-01-01

    An improved simultaneous tomography cassette according to P. Landau was tried out for four months using four tomographs in routine work. The mode of operation is based on accurate control of the relative speeds of the individual x-ray films resulting in simultaneous imaging of 6 equidistant tomographic levels. Clinical testing was effected in 80 cases: nephrotomography, of the lungs, the hilum, and the skeleton. In particular, the article describes imaging of the renal arteries by simultaneous tomography for the purpose of finding out the cause of hypertension, and if there is suspicion of a space-occupying growth in the kidney, basing on the urogram. The specific advantages of this technique are, on the one hand, improved diagnostic efficiency (the tomograms are taken during the same respiratory phase, more rapid diagnosis especially with accident patients), and, on the other hand, an important reduction in the x-ray exposure of the patient; furthermore, the life of the x-ray tube is prolonged, and there is a definite saving of time for both patient and personnel, the image quality being comparable with that of single-layer tomography. (orig.) [de

  19. Comparing staging by positron emission tomography with contrast-enhanced computed tomography and by pathology in head and neck squamous cell carcinoma.

    Science.gov (United States)

    Qualliotine, J R; Mydlarz, W K; Chan, J Y K; Zhou, X; Wang, H; Agrawal, N

    2015-12-01

    This study aimed to evaluate the ability of positron emission tomography with contrast-enhanced computed tomography to correctly stage head and neck squamous cell carcinomas, in comparison with pathological staging. Positron emission tomography computed tomography was used to determine the tumour-node-metastasis classification and overall cancer stage in 85 head and neck squamous cell carcinoma patients who underwent pre-operative imaging using this modality and primary surgery between July 2010 and January 2013. Staging by positron emission tomography computed tomography was retrospectively compared with staging using pathological specimens. Agreement between imaging stage and pathological stage was examined by univariate and multivariate analysis both overall and for each primary tumour site. This imaging modality was 87.5 per cent sensitive and 44.8 per cent specific in identifying regional cervical metastases, and had false positive and false negative rates of 18.8 per cent and 8.2 per cent, respectively. The positive predictive and negative predictive values were 75.4 per cent and 65.0 per cent, respectively. Univariate and multivariate analyses revealed a significant agreement between positron emission tomography computed tomography and pathological node classification in older patients and for the oral cavity primary tumour site. There was significant agreement between both methods in the overall classification only for tumours classified as T3 or greater. Positron emission tomography computed tomography should be used with caution for the pre-operative staging of head and neck cancers because of its high false positive and false negative rates.

  20. As causas imediatas do crescimento da renda, da redução da desigualdade e da queda da extrema pobreza na Bahia, no Nordeste e no Brasil entre 2003 e 2011

    OpenAIRE

    de Souza, Pedro H. G. F.

    2013-01-01

    O objetivo deste trabalho é explicar as causas imediatas do crescimento da renda domiciliar per capita, da redução da desigualdade e da queda da extrema pobreza para cinco recortes geográficos – Brasil, Nordeste, Bahia, Região Metropolitana (RM) de Salvador e Bahia não metropolitana – durante o período recente de crescimento pró-pobre (2003-2011). Com base em decomposições dinâmicas dos três aspectos, este texto procura verificar se as mudanças dos últimos anos seguem ou não um mesmo padrão g...

  1. Evapotranspiração da cultura da cebola

    Directory of Open Access Journals (Sweden)

    G. M. Oliveira

    2015-10-01

    Full Text Available A determinação da quantidade de água necessária para as culturas é um dos principais fatores para o correto planejamento, dimensionamento e manejo de qualquer sistema de irrigação. O presente trabalho teve como objetivo, comparar medida da evapotranspiração da cultura (ETc da cebola com estimativa obtida a partir da evapotranspiração de referência (ETo determinada por diferentes métodos e Kc proposto na literatura. O experimento foi conduzido no campo experimental do Departamento de Tecnologia e Ciências Sociais da Universidade do Estado da Bahia - UNEB, em Juazeiro, no período de junho a setembro de 2011. As medidas da ETc foram obtidas em evapotranspirômetros e as estimativas, a partir de ETo determinada pelos métodos: Penman-Monteith (padrão FAO, Penman-Monteith modificado por Villa Nova et al. (2004, Hargreaves & Samani, Makkink e Jensen & Haise e Kc proposto por Marouelli et al. (2005, para a cultura da cebola. É fundamental a avaliação de métodos de estimativa da evapotranspiração de referência antes de sua aplicação, pois erros consideráveis podem ser cometidos na determinação da quantidade de água a ser aplicada a uma cultura, o que repercutirá certamente, na produtividade.Evapotranspiration crop onionAbstract: The determination of the amount of water needed for crops is a major factor for the correct planning, sizing and management of any irrigation system. This study aimed to compare measure of crop evapotranspiration (ETc onion with estimates obtained from the reference evapotranspiration (ETo determined by different methods and Kc proposed in the literature. The experiment was conducted in the experimental field of the Department of Technology and Social Sciences, University of the State of Bahia, in Juazeiro, from June to September 2011. The ETc measurements were obtained in evapotranspirometers and estimates, from ETo determined by the methods: Penman-Monteith (FAO standard, Penman-Monteith modified

  2. Paracoccidioidomycosis: high-resolution computed tomography - anatomo-pathological correlation; Paracoccidioidomicose: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson; Muniz, Maria Angelica Soares; Santos, Maria Lucia de Oliveira [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Radiologia; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Inst. de Patologia; Capone, Domenico [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Pneumologia

    2000-12-01

    We reviewed the high-resolution computed tomography scans of 13 patients with paracoccidioidomycosis and correlated the findings with the anatomo-pathological findings of 5 patients. The most frequent findings observed were thickening of the interlobular septa, emphysema, ground glass areas, thickening of bronchial walls, tracheal dilatation, nodules, cavities and evidence of fibrosing disease such as architectural distortion, parenchymatous bands, spicular pleural thickening, intralobular reticulate and thickening with distortion off the axial interstitium. (author)

  3. Magnetic resonance tomography in syringomyelia

    International Nuclear Information System (INIS)

    Koehler, D.; Treisch, J.; Hertel, G.; Schoerner, W.; Fiegler, W.; Staedtisches Rudolf-Virchow Krankenhaus, Berlin

    1985-01-01

    Thirteen patients with a clinical diagnosis of syringomyelia were examined by nuclear tomography (0.35 T magnet) in the spin-echo mode. In all thirteen patients, the T1 images (Se 400/35) showed a longitudinal cavity with a signal intensity of CSF. The shape and extent of the syrinx could be adequately demonstrated in 12 of the 13 examinations. Downward displacement of the cerebellar tonsils was seen in eight cases. The examination took between half and one hour. Advantages of magnetic resonance tomography (nuclear tomography) include the absence of artifacts, images in the line of the lesion and its non-invasiveness. (orig.) [de

  4. Diagnostic utility of fluorodeoxyglucose positron emission tomography/computed tomography in pyrexia of unknown origin

    International Nuclear Information System (INIS)

    Singh, Nidhi; Kumar, Rakesh; Malhotra, Arun; Bhalla, Ashu Seith; Kumar, Uma; Sood, Rita

    2005-01-01

    The present study was undertaken to evaluate the diagnostic utility of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) in patients presenting as pyrexia of unknown origin (PUO). Forty-seven patients (31 males and 16 females; mean age of 42.7 ± 19.96 years) presenting as PUO to the Department of Medicine at the All India Institute of Medical Sciences, New Delhi over a period of 2 years underwent F-18 FDG PET/CT. PET ⁄ CT was considered supportive when its results correlated with the final definitive diagnosis. Final diagnosis was made on the basis of combined evaluation of history, clinical findings, investigations, and response to treatment. Thirty-five PET/CT studies (74.5%) were positive. However, only 18 (38.3%) were supportive of the final diagnosis. In three patients (6.4%), PET/CT was considered diagnostic as none of the other investigations including contrast-enhanced computed tomography of chest and abdomen, and directed tissue sampling could lead to the final diagnosis. All these three patients were diagnosed as aortoarteritis. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography is an important emerging modality in the workup of PUO. It supported the final diagnosis in 38% of our patients and was diagnostic in 6.4% of patients. Thus, PET/CT should only be considered as second-line investigation for the diagnostic evaluation of PUO; especially in suspected noninfectious inflammatory disorders

  5. 76 FR 27861 - Airworthiness Directives; Diamond Aircraft Industries GmbH Models DA 42, DA 42 NG, and DA 42 M-NG...

    Science.gov (United States)

    2011-05-13

    ... Airworthiness Directives; Diamond Aircraft Industries GmbH Models DA 42, DA 42 NG, and DA 42 M-NG Airplanes... on Diamond aeroplanes, the majority of which were DA 40. In additional, at least 18 doors have been... conditions) while the aeroplane was parked. All DA 40 and DA 42 aeroplanes have a system installed that...

  6. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  7. Dynamic emission tomography of regional cerebral blood flow

    International Nuclear Information System (INIS)

    Lassen, N.A.

    1984-01-01

    The author reviews three tomographic methods for measuring the regional cerebral blood flow: single photon transmission tomography; dual photon emission tomography; and single photon emission tomography. The latter technique is discussed in detail. (Auth.)

  8. Efeitos cerebrais da maconha: resultados dos estudos de neuroimagem Brain effects of cannabis: neuroimaging findings

    Directory of Open Access Journals (Sweden)

    José Alexandre Crippa

    2005-03-01

    Full Text Available A maconha é a droga ilícita mais utilizada. Apesar disto, apenas um pequeno número de estudos investigaram as conseqüências neurotóxicas de longo prazo do uso de cannabis. As técnicas de neuroimagem se constituem em poderosos instrumentos para investigar alterações neuroanatômicas e neurofuncionais e suas correlações clínicas e neuropsicológicas. Uma revisão computadorizada da literatura foi conduzida nos indexadores MEDLINE e PsycLIT entre 1966 e novembro de 2004 com os termos 'cannabis', 'marijuana', 'neuroimaging', 'magnetic resonance', 'computed tomography', 'positron emission tomography', 'single photon emission computed tomography", 'SPET', 'MRI' e 'CT'. Estudos de neuroimagem estrutural apresentam resultados conflitantes, com a maioria dos estudos não relatando atrofia cerebral ou alterações volumétricas regionais. Contudo, há uma pequena evidência de que usuários de longo prazo que iniciaram um uso regular no início da adolescência apresentam atrofia cerebral assim como redução na substância cinzenta. Estudos de neuroimagem funcional relatam aumento na atividade neural em regiões que podem estar relacionadas com intoxicação por cannabis e alteração do humor (lobos frontais mesial e orbital e redução na atividade de regiões relacionadas com funções cognitivas prejudicadas durante a intoxicação aguda. A questão crucial se efeitos neurotóxicos residuais ocorrem após o uso prolongado e regular de maconha permanece obscura, não existindo até então estudo endereçando esta questão diretamente. Estudos de neuroimagem com melhores desenhos, combinados com avaliação cognitiva, podem ser elucidativos neste aspecto.Cannabis is the most widely used illicit drug. Despite this, only a small number of studies have investigated the long-term neurotoxic consequences of cannabis use. Structural and functional neuroimaging techniques are powerful research tools to investigate possible cannabis

  9. SOBRE OS FUNDAMENTOS DA ARQUITETURA DA INFORMAÇÃO

    Directory of Open Access Journals (Sweden)

    Alfram Roberto Rodrigues de Albuquerque

    2011-10-01

    Full Text Available Expõe-se o estado atual da disciplina Arquitetura da Informação quanto a problemática terminológica da definição do campo de estudo, apresentando-se argumentos para uma definição de Arquitetura da Informação de uma forma ampla na qual os usos correntes dessa expressão sejam vistos como especializações. Defende-se uma definição com a utilização de um conjunto de propriedades mínimas cujas interações levam a uma terminologia formal e cuja abstração leva a uma definição formal do conceito que emprega a linguagem de morfismos da Teoria das Categorias. Trata-se de um recorte de alguns dos resultados obtidos na tese de doutoramento de um dos autores, defendida em setembro de 2010. O contexto da pesquisa é exposto e alguns dos resultados obtidos são delineados.

  10. 76 FR 12627 - Airworthiness Directives; Diamond Aircraft Industries GmbH Models DA 42, DA 42 NG, and DA 42 M-NG...

    Science.gov (United States)

    2011-03-08

    ... Industries GmbH Models DA 42, DA 42 NG, and DA 42 M-NG Airplanes AGENCY: Federal Aviation Administration (FAA... on Diamond aeroplanes, the majority of which were DA 40. In additional, at least 18 doors have been... conditions) while the aeroplane was parked. All DA 40 and DA 42 aeroplanes have a system installed that...

  11. Introduction to Seismic Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, Charlotte Anne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-21

    Tomography is a method of obtaining an image of a 3d object by observing the behavior of energy transmissions through the object. The image is obtained by Interrogating the object with Energy sources at a variety of Locations and observing the Object’s effects on the energy at a Variety of sensors. Tomography was first Used to build 3-dimensional Scans through Human bodies. These Are called computed Tomographic (ct) scans.

  12. Use of computed tomography and positron emission tomography/computed tomography for staging of local extent in patients with malignant pleural mesothelioma.

    Science.gov (United States)

    Frauenfelder, Thomas; Kestenholz, Peter; Hunziker, Roger; Nguyen, Thi Dan Linh; Fries, Martina; Veit-Haibach, Patrick; Husmann, Lars; Stahel, Rolf; Weder, Walter; Opitz, Isabelle

    2015-01-01

    The objective of this study was to determine the diagnostic value of computed tomography (CT) and positron emission tomography (PET)/CT for staging of malignant pleural mesothelioma (MPM) in patients undergoing induction chemotherapy. Sixty-two patients (median age, 61 years; female: n = 9) with proven MPM underwent CT after induction chemotherapy. Of these, 28 underwent additional PET/CT. Extrapleural pneumonectomy was performed for pathological TNM staging. Clinical TNM stage was assessed by 3 independent readers. Relative and absolute underestimation and overestimation were compared with pathological tumor stage. Sensitivity, specificity, and accuracy for differentiation between stages T2 and T3 were assessed. Interobserver agreement between the readers was analyzed (κ). Positron emission tomography/CT and CT underestimated T stage in up to 30% of the cases. Positron emission tomography/CT had a higher accuracy for tumor extent compared with CT (PET/CT: 0.92; CT: 0.84). The accuracy for nodal staging was higher for CT than for PET/CT (PET/CT: 0.78; CT: 0.87). Concerning International Mesothelioma Interest Group classification, PET/CT improved the accuracy of preoperative staging compared with CT (PET/CT: 0.91; CT: 0.82). Interobserver agreement was moderate for CT (0.48-0.62) and good for PET/CT (0.64-0.83) for T staging. For nodal staging, interobserver agreement was fair to moderate for CT and good for PET/CT (CT: 0.37-0.51; PET/CT: 0.73-0.76). Positron emission tomography/CT is more accurate and has a lower interobserver variability for clinical intrathoracic staging of MPM compared with CT. Nevertheless PET/CT underestimated tumor stage in a substantial number of cases, showing the need for a more accurate imaging technology or approach.

  13. A inclusão da subjetividade no ensino da Psicopatologia

    Directory of Open Access Journals (Sweden)

    Octavio Domont de Serpa Junior

    2007-08-01

    Full Text Available O estudo da Psicopatologia tem sido freqüentemente apresentado em sua dimensão descritiva. Apesar da relevância para o ensino - auxiliar o aluno a reconhecer a dimensão sintomatológica dos quadros psicopatológicos -, exclui a dimensão subjetiva da experiência do adoecimento e seus aspectos relacionais. Partindo da tradição antropológico-existencial, apresentamos uma experiência de ensino de Psicopatologia que considera tais dimensões relevantes para a compreensão do sofrimento mental. Trabalhando com estudo de caso descritivo, são apresentadas duas novas modalidades de práticas na disciplina Psicopatologia Especial I, oferecida para alunos do curso de Psicologia da UFRJ. A proposta é ampliar o ensino prático, tradicionalmente centrado no modelo da extensa entrevista clínica, realizada diante de um grande grupo de alunos que a tudo assistem passivamente. Pretendemos aproximar o ensino e a prática da Psicopatologia dos ideais da Reforma Psiquiátrica Brasileira, que concebe o adoecimento mental como fenômeno complexo, envolvendo a relação do sujeito com o mundo.

  14. Autocorrelation descriptor improvements for QSAR: 2DA_Sign and 3DA_Sign

    Science.gov (United States)

    Sliwoski, Gregory; Mendenhall, Jeffrey; Meiler, Jens

    2016-03-01

    Quantitative structure-activity relationship (QSAR) is a branch of computer aided drug discovery that relates chemical structures to biological activity. Two well established and related QSAR descriptors are two- and three-dimensional autocorrelation (2DA and 3DA). These descriptors encode the relative position of atoms or atom properties by calculating the separation between atom pairs in terms of number of bonds (2DA) or Euclidean distance (3DA). The sums of all values computed for a given small molecule are collected in a histogram. Atom properties can be added with a coefficient that is the product of atom properties for each pair. This procedure can lead to information loss when signed atom properties are considered such as partial charge. For example, the product of two positive charges is indistinguishable from the product of two equivalent negative charges. In this paper, we present variations of 2DA and 3DA called 2DA_Sign and 3DA_Sign that avoid information loss by splitting unique sign pairs into individual histograms. We evaluate these variations with models trained on nine datasets spanning a range of drug target classes. Both 2DA_Sign and 3DA_Sign significantly increase model performance across all datasets when compared with traditional 2DA and 3DA. Lastly, we find that limiting 3DA_Sign to maximum atom pair distances of 6 Å instead of 12 Å further increases model performance, suggesting that conformational flexibility may hinder performance with longer 3DA descriptors. Consistent with this finding, limiting the number of bonds in 2DA_Sign from 11 to 5 fails to improve performance.

  15. Parâmetros erosividade da chuva, da enxurrada e da chuva-enxurrada correlacionados com as perdas de solo de um luvissolo

    Directory of Open Access Journals (Sweden)

    A. W. Albuquerque

    2002-09-01

    Full Text Available Foram estudadas as correlações lineares simples, múltiplas e não-lineares entre os parâmetros erosividade da chuva, da enxurrada e da chuva-enxurrada e as perdas de solo provocadas por chuvas erosivas num Luvissolo. Os dados correspondentes ao período de 1986-1990 foram obtidos na estação experimental de Sumé (PB, pertencente à Universidade Federal da Paraíba - UFPB. Para determinar os parâmetros erosividade da chuva, da enxurrada e da chuva-enxurrada, foram analisadas chuvas individuais registradas em 136 pluviogramas. O volume de enxurrada isolado ou em combinação com características da chuva contribuiu, de forma significativa, para melhorar a estimativa das perdas de solo de chuvas individuais. Os parâmetros erosividade da chuva-enxurrada a(Vu α I30b; a(Vu α I5b; a(EIAb e da enxurrada a(Vub foram os melhores estimadores das perdas de solo para chuvas individuais. Dentre os parâmetros da erosividade da chuva, os que melhor se correlacionaram com as perdas de solo foram aqueles que incluíram o produto do volume da chuva pela intensidade máxima em trinta minutos a(VrI30.

  16. Oblique hilar tomography, computed tomography, and mediastinoscopy for prethoracotomy staging of bronchogenic carcinoma

    International Nuclear Information System (INIS)

    Khan, A.; Gersten, K.C.; Garvey, J.; Khan, F.A.; Steinberg, H.

    1985-01-01

    Preoperative oblique hilar tomography was used to evaluate hilar lymph nodes in 150 patients with clinically resectable bronchogenic carcinoma. CT was also used in the evaluation of mediastinal lymph nodes in 50 of these patients. Subsequently, all patients underwent mediastinoscopy and/or thoracotomy. Hilar and mediastinal nodes were evaluated for the presence of metastasis, and these findings were then correlated with the radiographic findings of oblique hilar tomography and CT. CT was found to be a reliable method for prethoracotomy staging of bronchogenic carcinoma and for selecting patients for mediastinoscopy. Thus patients with negative mediastinal CT need not undergo mediastinoscopy prior to thoracotomy, while mediastinoscopy and biopsy should be done in patients with enlarged mediastinal nodes on CT. Oblique hilar tomography is an accurate method for evaluation of hilar adenopathy and for predicting mediastinal involvement by extrapolation

  17. Evaluation of water content in rock mass by electromagnetic and resistivity tomography. Denjiha, hiteiko tomography ni yoru ganban no gansui jotai hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Inaba, T; Inoue, M; Matsumoto, K [Kajima Corp., Tokyo (Japan)

    1993-10-31

    As a method to evaluate the rock mass, electromagnetic tomography and resistivity tomography were tested on the original site. The electromagnetic tomography can tomographically analyze the propagation velocity and initial amplitude damping. The resistivity tomography uses a finite element method from the initial resistivity distribution model and finally gives a model which is nearly equal to the actual resistivity distribution. Both the above tomographic analyses can detect the crushed spot as a low velocity, high damping and low resistivity spot. However, the electromagnetic tomography could detect finer structure than the resistivity tomography. The water content of rock mass was evaluated from the damping coefficient which was given by the amplitude damping tomography of electromagnetic wave. If it is compared with the water content which is given by the dielectric constant of velocity tomography, there partially exists discrepancy between both, because the damping coefficient contains information on cracks which disperse and reflect the electromagnetic wave. Between the resistivity and porosity, there exists a known experimental formula, which was satisfied by the presently given resistivity. 9 refs., 10 figs.

  18. Optical Coherence Tomography of the Aging Kidney.

    Science.gov (United States)

    Andrews, Peter M; Wang, Hsing-Wen; Guo, Hengchang; Anderson, Erik; Falola, Reuben; Chen, Yu

    2016-12-01

    The aging kidney exhibits a progressive decline in renal function with characteristic histopathologic changes and is a risk factor for renal transplant. However, the degree to which the kidney exhibits this decline depends on several factors that vary from one individual to the next. Optical coherence tomography is an evolving noninvasive imaging technology that has recently been used to evaluate acute tubular necrosis of living-human donor kidneys before their transplant. With the increasing use of kidneys from older individuals, it is important to determine whether optical coherence tomography also can distinguish the histopathology associated with aging. In this investigation, we used Munich-Wistar rats to evaluate the ability of optical coherence tomography to detect histopathologic changes associated with aging. Optical coherence tomography observations were correlated with renal function and conventional light microscopic evaluation of these same kidneys. With the onset of severe proteinuria at 10 to 12 months of age, optical coherence tomography revealed tubular necrosis/atrophy, interstitial fibrosis, tubular dilation, and glomerulosclerosis. With a further deterioration in kidney function at 16 to 18 months of age (as indicated by rising creatinine levels), optical coherence tomography revealed more extensive interstitial fibrosis and tubular atrophy, increased tubular dilation with cyst formation and more sclerotic glomeruli. The foregoing observations suggest that optical coherence tomography can be used to detect the histopathology of progressive nephropathy associated with aging.

  19. CONTRIBUIÇÃO PARA O CONHECIMENTO DA GEOMORFOLOGIA DA CADEIA DA ARRÁBIDA (PORTUGAL: CARTOGRAFIA GEOMORFOLÓGICA E GEOMORFOMETRIA

    Directory of Open Access Journals (Sweden)

    André Filipe Fonseca

    2015-03-01

    Full Text Available A cadeia da Arrábida resulta da interação de processos tectónicos e erosivos ao longo de um período de tempo alargado, situado entre o Miocénico médio e a atualidade. O desmantelamento da cadeia processou-se em função da componente de movimentação tectónica, da posição da linha de costa e dos processos erosivos a ela associados, desempenhando a rede hidrográfica um papel fundamental no restabelecimento do equilíbrio dinâmico entre processos endógenos e exógenos. Esta relação está expressa no escalonamento altitudinal de formas erosivas aplanadas e suspensas sobre a rede de drenagem atual, evidenciando uma evolução policíclica do relevo controlada pelo levantamento da Serra da Arrábida, pela subsidência do Sinclinal de Albufeira e pelas oscilações do nível do mar no decorrer do período plio-quaternário. Sobrepõe-se a este processo o rejogo vertical de falhas de orientação NNE-SSW a NE-SW evidenciando um aumento progressivo da deformação de oeste para leste. O presente trabalho pretende contribuir para o conhecimento da geomorfologia da cadeia da Arrábida recorrendo a técnicas de geomorfometria para a extração semiautomática e análise de formas de relevo. Dado o contexto morfotectónico, é dada particular atenção à interferência da tectónica na evolução do relevo.

  20. Three-dimensional fluorescence lifetime tomography

    International Nuclear Information System (INIS)

    Godavarty, Anuradha; Sevick-Muraca, Eva M.; Eppstein, Margaret J.

    2005-01-01

    Near-infrared fluorescence tomography using molecularly targeted lifetime-sensitive, fluorescent contrast agents have applications for early-stage cancer diagnostics. Yet, although the measurement of fluorescent lifetime imaging microscopy (FLIM) is extensively used in microscopy and spectroscopy applications, demonstration of fluorescence lifetime tomography for medical imaging is limited to two-dimensional studies. Herein, the feasibility of three-dimensional fluorescence-lifetime tomography on clinically relevant phantom volumes is established, using (i) a gain-modulated intensified charge coupled device (CCD) and modulated laser diode imaging system, (ii) two fluorescent contrast agents, e.g., Indocyanine green and 3-3'-Diethylthiatricarbocyanine iodide differing in their fluorescence lifetime by 0.62 ns, and (iii) a two stage approximate extended Kalman filter reconstruction algorithm. Fluorescence measurements of phase and amplitude were acquired on the phantom surface under different target to background fluorescence absorption (70:1, 100:1) and fluorescence lifetime (1:1, 2.1:1) contrasts at target depths of 1.4-2 cm. The Bayesian tomography algorithm was employed to obtain three-dimensional images of lifetime and absorption owing to the fluorophores

  1. Roles of computed tomography and [18F]fluorodeoxyglucose-positron emission tomography/computed tomography in the characterization of multiple solitary solid lung nodules

    OpenAIRE

    Travaini, LL; Trifirò, G; Vigna, PD; Veronesi, G; De Pas, TM; Spaggiari, L; Paganelli, G; Bellomi, M

    2012-01-01

    The purpose of this study is to compare the performance of multidetector computed tomography (CT) and positron emission tomography/CT (PET/CT) with [18F]fluorodeoxyglucose in the diagnosis of multiple solitary lung nodules in 14 consecutive patients with suspicious lung cancer. CT and PET/CT findings were reviewed by a radiologist and nuclear medicine physician, respectively, blinded to the pathological diagnoses of lung cancer, considering nodule size, shape, and location (CT) and maximum st...

  2. 4D Electron Tomography

    Science.gov (United States)

    Kwon, Oh-Hoon; Zewail, Ahmed H.

    2010-06-01

    Electron tomography provides three-dimensional (3D) imaging of noncrystalline and crystalline equilibrium structures, as well as elemental volume composition, of materials and biological specimens, including those of viruses and cells. We report the development of 4D electron tomography by integrating the fourth dimension (time resolution) with the 3D spatial resolution obtained from a complete tilt series of 2D projections of an object. The different time frames of tomograms constitute a movie of the object in motion, thus enabling studies of nonequilibrium structures and transient processes. The method was demonstrated using carbon nanotubes of a bracelet-like ring structure for which 4D tomograms display different modes of motion, such as breathing and wiggling, with resonance frequencies up to 30 megahertz. Applications can now make use of the full space-time range with the nanometer-femtosecond resolution of ultrafast electron tomography.

  3. Computed tomography in renal trauma

    International Nuclear Information System (INIS)

    Brueck, W.; Eisenberger, F.; Buck, J.

    1981-01-01

    In a group of 19 patients suffering from flank trauma and gross hematuria the diagnostic value of angiography was compared with that of computed tomography. The cases that underwent both tests were found to have the some diagnosis of rupture of the kidney. Typical CT-findings in kidney rupture are demonstrated. Whereas angiography presents an exact picture of the arterial system of the kidney, including its injures computed tomography reveals the extent of organ lesons by showing extra- and intrarenal hematomas. If surgery is planned angiography is still mandatory, whereby the indication is largely determined by the clinical findings. Computed tomography as a non-invasive method is equally suitable for follow-ups. (orig.) [de

  4. Photons-based medical imaging - Radiology, X-ray tomography, gamma and positrons tomography, optical imaging; Imagerie medicale a base de photons - Radiologie, tomographie X, tomographie gamma et positons, imagerie optique

    Energy Technology Data Exchange (ETDEWEB)

    Fanet, H.; Dinten, J.M.; Moy, J.P.; Rinkel, J. [CEA Leti, Grenoble (France); Buvat, I. [IMNC - CNRS, Orsay (France); Da Silva, A. [Institut Fresnel, Marseille (France); Douek, P.; Peyrin, F. [INSA Lyon, Lyon Univ. (France); Frija, G. [Hopital Europeen George Pompidou, Paris (France); Trebossen, R. [CEA-Service hospitalier Frederic Joliot, Orsay (France)

    2010-07-01

    This book describes the different principles used in medical imaging. The detection aspects, the processing electronics and algorithms are detailed for the different techniques. This first tome analyses the photons-based techniques (X-rays, gamma rays and visible light). Content: 1 - physical background: radiation-matter interaction, consequences on detection and medical imaging; 2 - detectors for medical imaging; 3 - processing of numerical radiography images for quantization; 4 - X-ray tomography; 5 - positrons emission tomography: principles and applications; 6 - mono-photonic imaging; 7 - optical imaging; Index. (J.S.)

  5. O uso da aromaterapia na melhora da autoestima

    Directory of Open Access Journals (Sweden)

    Juliana Rizzo Gnatta

    2011-10-01

    Full Text Available Os objetivos deste estudo foram verificar se a inalação dos óleos essenciais de rosa e de ylang-ylang alteram a percepção da autoestima e comparar a eficácia dos mesmos. O projeto foi aprovado pelo Comitê de Ética em Pesquisa do Hospital da Universidade de São Paulo. Participaram 43 funcionários dos setores de Higienização e da Central de Materiais e Esterilização durante os meses de maio a julho de 2009. Os sujeitos foram randomizados em três grupos: dois que receberem os óleos essenciais e outro que recebeu placebo (essência de rosa. A avaliação da autoestima foi feita através de uma escala já validada no Brasil, sendo aplicada antes do uso dos aromas, depois de 30 dias de uso e ao completar 60 dias. Dentre os resultados, verificou-se que a amostra era constituída por 88,6% de indivíduos com média e alta autoestima e que os óleos essenciais em questão não alteraram de forma significativa a percepção da autoestima.

  6. Comparative analysis of quality control tests on computed tomography in accordance with national and international laws

    International Nuclear Information System (INIS)

    Ramos, Fernando S.; Vasconcelos, Rebeca S.; Goncalves, Marcel S.; Oliveira, Marcus V.L. de

    2014-01-01

    The objective of this study is to perform a comparative analysis between the Brazilian legislation and internationals protocols, with respect to the quality control tests for computerized tomography. We used 07 references, published from 1998-2012: the Protocolo Brasileiro - Portaria 453/98 SVS/MS and the Guia de Radiodiagnostico Medico da ANVISA; Quality Assurance Programme for Computed Tomography: Diagnostic and Therapy Applications of the IAEA; European Protocol - European Guidelines on Quality Criteria for Computed Tomography of the EUR No. 16262 EN; Radiation Protection No. 162 - Criteria for Acceptability of Medical Radiology, Nuclear Medicine and Radiotherapy of the European Commission; the Protocols of Control de Calidad en Radiodiagnostico IAEA / ARCAL XLIX; and the Protocolo Espanol de Control de Calidad en Radiodignostico. The comparative analysis of these legislations was based on aspects of tolerance / limit, frequency and objectives of the recommended tests. Were found 18 tests in the Brazilian legislation. The tests were grouped according to their nature (dosimetric tests / exposure and geometric tests and image quality tests). Among the evaluated protocols was identified divergence between tests contained in the documents and the criteria of assessment set out in this work. It is clear, moreover, that for certain documents are not observed tolerances, well-defined methodologies and even frequency of testing. We conclude that the current legislation in Brazil differs in certain respects from international protocols analyzed, although this has a great numbers of quality control tests. However, it is necessary that the Brazilian legislation takes into account technological advances presented to time

  7. Increased fluoro-deoxy-D-glucose uptake on positron emission tomography-computed tomography postbronchoalveolar lavage: a potential cause of radiologic misinterpretation.

    LENUS (Irish Health Repository)

    Leong, Sum

    2011-08-01

    Cytologic analysis of bronchoalveolar lavage (BAL) fluid is used for lung cancer diagnosis. We describe a patient with a history of rectal carcinoma who presented with a new lung mass. BAL was performed, with positron emission tomography-computed tomography the following day. There was mildly increased fluoro-deoxy-D-glucose uptake in areas of the lung parenchyma with new ground-glass opacification. This created ambiguity in staging, clarified 2 weeks later by a computed tomography showing complete resolution of the ground-glass opacity. Clinicians should be aware that BAL may cause increased pulmonary fluoro-deoxy-D-glucose uptake, making accurate radiologic interpretation problematic. We suggest that to optimize positron emission tomography-computed tomography, studies should not be performed within 24 hours of BAL.

  8. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  9. Da Vinci robot-assisted anatomic left hemihepatectomy and biliary reconstruction.

    Science.gov (United States)

    Wang, Zhifei; Liu, Quanda; Chen, Junzhou; Duan, Weihong; Zhou, Ningxin

    2013-06-01

    Since the introduction of Da Vinci robotic surgery, more and more complicated surgeries can now be performed robotically, yet there have been very few on robotic hepatectomy, especially when billiary reconstruction is involved. The video shows our initial experience with an anatomic hepatectomy using Da Vinci surgical robot. In this case, we also conducted billiary reconstruction due to the anatomic abnormality of bile duct, while applying the choledochoscopy. The preoperative diagnosis is primary liver carcinoma, tumor thrombi in bile duct, and hepatitis B. First, the gallbladder was resected, and cystic artery and duct were identified. After opening of the common bile duct above the junction, the choledochoscopy was performed. Tumor thrombi were found in common bile duct and left hepatic duct, and they were all removed. Left branches hepatic artery and portal vein were dissected, ligated, and divided. Thrombi in the left hepatic duct were removed also. After marking the cutting line along the ischemic boarder, liver parenchyma was transected using robotic harmonic scalpel. Branches of ducts were encountered and managed by either direct coagulating or dividing after clipping. The left hepatic vein was visualized, exposed, and divided during hepatectomy. Two T tubes were placed into common hepatic duct and the proximal cutting end of right anterior bile duct which was found to join the left hepatic duct, respectively. The operation went on successfully. The operation time was 410 minutes, the blood loss was 200 mL. The pathologic diagnosis was introductal papillary adenocarcinoma of left hepatic duct. The patient went on well postoperatively and was followed up for 22 months till now. Postoperative computed tomography examination showed no recurrence. Da Vinci-assisted robotic hepatectomy can be performed safely in the hands of experienced hepatobilliary surgeons, and choledochoscopy can be combined for bile duct exploration. With the advantages of Da Vinci robot

  10. Da onda da gestão da qualidade a uma filosofia da qualidade da gestão: Balanced Scorecard promovendo mudanças

    Directory of Open Access Journals (Sweden)

    Andréa Cavalcanti Correia Lima

    2004-06-01

    Full Text Available No final da década de 80 a Gestão da Qualidade Total (GQT era apresentada como capaz de resolver todos os problemas e atender a todas as necessidades da gestão das organizações. Buscando solucionar problemas de gestão não equacionados pela GQT, muitas organizações começam a adotar o Balanced Scorecard (BSC. Uma questão ainda não discutida com profundidade no mundo acadêmico é a viabilidade de integração desses dois modelos. O presente artigo discute a possibilidade de integração dessas duas ferramentas, verificando as melhorias que podem alcançar, principalmente no gerenciamento da estratégia da organização. Assim sendo, realizou-se estudo de caso no Caesar Park Hotel Fortaleza (CPHF, empresa que vêm adotando com sucesso os dois modelos. A pesquisa revela que é possível integrar os princípios da GQT com os do BSC, à medida que os fundamentos de ambos se complementam, sendo assim a utilização conjunta das ferramentas propicia melhor gerenciamento da estratégia da organização.In recent years, many organizations have been managed according to the principles of Total Quality Management (TQM, which became known around the globe in the 1980's, when looking for explanations for the so-called "Japanese miracle". TQM was presented as being capable of solving all problems and attending to all company management needs, a stage that seems outdated now. In the search for a model that would allow them to analyze and follow up the implementation of organizational strategies, without remaining limited to Quality indicators, many companies started to adopt the Balanced Scorecard (BSC. Companies using TQM question whether it is viable together with the BSC. In order to contribute to a solution to this question, this article discusses the possibility of aligning these two tools. Therefore, a case study was carried out at the Caesar Park Hotel Fortaleza, a company that implanted TQM in 1997 and started to adopt the BSC in 2000. The

  11. Single photon emission computerized tomography (SPECT)

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as 123 I and 99 Tc m that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  12. Single photon emission computerized tomography (SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Ganatra, R D

    1993-12-31

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as {sup 123}I and {sup 99}Tc{sup m} that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  13. Digital multilayer tomography

    International Nuclear Information System (INIS)

    Dueber, C.; Klose, K.J.; Thelen, M.

    1991-01-01

    With digital multilayer tomography a sequence of projection images is recorded by an image intensifier television system and stored as digital data during a linear run of a layer sequence. Using this data record, tomograms of the examined body region can be computed for any layer thickness by shifts and superimposition of the single projections later at a digital workstation. The qualities of digital and conventional tomograms are basically comparable. A drawback of digital tomography is its lower local resolution (512 x 512 image matrix), advantages are a lower radiation exposure, a shorter patient examination time, and the facilities of digital image processing (later processing, archive setup, transmission). (orig.) [de

  14. F-18-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Appearance of Extramedullary Hematopoesis in a Case of Primary Myelofibrosis

    Science.gov (United States)

    Mukherjee, Anirban; Bal, Chandrasekhar; Tripathi, Madhavi; Das, Chandan Jyoti; Shamim, Shamim Ahmed

    2017-01-01

    A 44-year-old female with known primary myelofibrosis presented with shortness of breath. High Resolution Computed Tomography thorax revealed large heterogeneously enhancing extraparenchymal soft tissue density mass involving bilateral lung fields. F-18-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography revealed mildly FDG avid soft tissue density mass with specks of calcification involving bilateral lung fields, liver, and spleen. Subsequent histopathologic evaluation from the right lung mass was suggestive of extramedullary hematopoesis. PMID:28533647

  15. A Lei Maria da Penha sob a perspectiva da ética da vingança / Maria da Penha law unde the ethics of revenge approach

    OpenAIRE

    Nunes, Thaísa Silva de Oliveira; Faculdade de Direito de Vitória

    2011-01-01

    RESUMO: Analisa-se a lei 11.340/2006, conhecida como Lei Maria da Penha, sob a perspectiva da ética da vingança, considerando-se a situação de seu uso de forma equivocada. Nesse sentido, argui-se que o judiciário deve tomar um cuidado maior ao julgar casos de violência doméstica. Aborda-se também a possibilidade de uma mulher abandonada ou ultrajada pelo seu companheiro reagir de forma a resgatar a confiança em si, ao invés de se utilizar da prática da vingança permitida pelos mecanismos jurí...

  16. Recurrent ovarian endodermal sinus tumor: demonstration by computed tomography, magnetic resonance imaging, and positron emission tomography

    International Nuclear Information System (INIS)

    Romero, J.A.; Kim, E.E.; Tresukosol, D.; Kudelka, A.P.; Edwards, C.L.; Kavanagh, J.J.

    1995-01-01

    We report a case of recurrent endodermal sinus tumor of the ovary that was identified and/or clearly depicted by computed tomography, magnetic resonance imaging, and positron emission tomography. The potential roles of various imaging modalities in the detection of recurrent endodermal sinus tumor are discussed. (orig.)

  17. A RELAÇÃO DA TELEVISÃO E DA INTERNET COM O CONSUMO: ANÁLISES DA IDEOLOGIA E DA CULTURA NAS PROPAGANDAS

    Directory of Open Access Journals (Sweden)

    Fábio Carlos Rodrigues Alves

    2016-10-01

    Full Text Available Mais que um meio de comunicação, as tecnologias da comunicação, em especial a TV, transmitem valores, ideias e atitudes, ou seja, todo um conteúdo atitudinal e procedimental. O presente texto discute o papel da mídia televisiva e da internet na transmissão de valores culturais, atendo-se principalmente na questão do consumo. Analisamos propagandas oriundas do ambiente televisivo e também a veiculada pela internet a partir da qual objetivamos, à luz do conceito de Cultura e Ideologia investigar e assinalar o condicionamento dos consumidores ao ato de consumo.

  18. Reflection tomography from pre-stack migrated images; Tomographie de reflexion a partir des images migrees avant addition

    Energy Technology Data Exchange (ETDEWEB)

    Adler, F

    1996-10-29

    The application of reflection tomography to data from complex geological structures is very interesting in the hydrocarbons exploration. Indeed, it contributes to localize the hydrocarbons potential traps. The used reflection tomography method is faced with two major difficulties. Travel time picking is difficult or impossible in seismic time sections. The processing of multiple arrival travel times needs an adequate formulation of reflection tomography. In order to solve the first problem, we adopt the approach of the SMART (Sequential Migration Aided Reflection Tomography) method which is an original method for the implementation of migration velocity analysis. The velocity model is automatically calculated by reflection tomography. The kinematic data set for reflection tomography is constructed from pre-stack depth-migrated images that are interpreted in the chosen migration configuration. For the implementation of the SMART method in the common-offset domain, we propose an original formulation of reflection tomography that takes multiple arrival travel times, which are calculated from common-offset migrated images, into account. In this new formulation, we look for a model such that a modelling, which consists in shooting in this model from the source locations with some ray parameters at the source, matches some emergence conditions: for each offset, the rays emerge at the receiver locations (given by the offset) with the same travel times and the same travel time slopes as observed in the associated common-offset section. These conditions constitute the kinematic data set for tomographic inversion. The common-offset travel time slope is the difference between the ray parameter at the receiver and the ray parameter at the source. Therefore, the ray parameter at the source is an unknown and has to be determined together with the model parameters during inversion. (author)

  19. O PAPEL DA ÁFRICA NA NOVA ROTA DA SEDA MARÍTIMA

    Directory of Open Access Journals (Sweden)

    Diego Pautasso

    2017-01-01

    Full Text Available O objetivo do presente artigo é analisar o lugar da África na construção da Nova Rota da Seda Marítima. Este é justamente um dos vetores do ambicioso projeto chinês de integração da Ásia, Europa e África, lançada em 2013 sob título de Iniciativa OBOR (One Belt, One Road. Na medida que os desafios da reconstrução nacional são superados, a China torna-se mais assertiva e dá forma à sua estratégia de inserção mundial. Nesse sentido, a Nova Rota da Seda agrega os objetivos centrais da diplomacia da China para o século XXI, reservando à África a condição de trampolim para que o projeto se torne global.

  20. ANÁLISE PRELIMINAR DA CONTROLADORIA DA CIDADE DE SALVADOR

    Directory of Open Access Journals (Sweden)

    João Marcelo Pitiá Barreto

    2012-06-01

    Full Text Available A Controladoria tem sido alvo de estudos e destaque de análises e reflexões dos estudiosos das ciências que têm como foco o campo gerencial das organizações como a da Administração e Contabilidade. É importante observar a contribuição da Controladoria à governança pública, fundamento de uma gestão democrática e participativa. Nesse contexto, insere-se o objetivo deste estudo, refletir sobre atuação da controladoria pública da cidade de Salvador, observando a contribuição efetiva na governança nesse município. Os estudos foram desenvolvidos na Secretaria da Fazenda (SEFAZ do município a quem Controladoria vincula-se. Com caráter exploratório, essa investigação descritiva envolveu pesquisa de campo, análise de documentos e relatórios emitidos pela SEFAZ e pelo Tribunal de Contas do Município (TCM. Verificou-se o organograma da SEFAZ, seu orçamento e os pareceres do TCM. Os resultados expressam a importância da Controladoria e denotam a impressão de que, na instituição estudada, essa área não esteja cumprindo bem seu papel. 

  1. UM ESTUDO DA INFLUÊNCIA DA GESTÃO DE PESSOAS NO DESEMPENHO DO TRABALHADOR E NA MELHORIA DA QUALIDADE

    Directory of Open Access Journals (Sweden)

    Crislaine Carvalho

    2017-01-01

    Full Text Available A qualidade é uma das principais preocupações presentes dentro das organizações, e estas estão sempre à procura de ferramentas que possam auxiliar nesse processo. A influência da gestão de pessoas no desempenho do trabalhador pode ser um diferencial para as empresas no mercado competitivo. Este trabalho tem a finalidade de apresentar o relacionamento entre a gestão de pessoas e a gestão da qualidade e seus reflexos no processo de melhoria contínua. Nesse contexto, foi feita uma revisão bibliográfica da evolução histórica da qualidade e os reflexos da gestão de pessoas nesse processo. Foi estudado também uma evolução do termo Gestão de Pessoas e suas diversas nomenclaturas adotadas ao longo do tempo, e as influências dessas nomenclaturas no relacionamento com os funcionários. Essa pesquisa trouxe resultados positivos a respeito da influência da gestão de pessoas na melhoria da qualidade, mostrando que os interesses da empresa e dos funcionários podem sim caminhar juntos, desde que ambos os lados estejam satisfeitos, o que confirmou a hipótese inicial desse trabalho.

  2. 21 CFR 892.1200 - Emission computed tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emission computed tomography system. 892.1200... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1200 Emission computed tomography system. (a) Identification. An emission computed tomography system is a device intended to detect the...

  3. Determination of the initial energy in computerized tomography with proton beams; Determinacao da energia inicial em tomografia computadorizada com feixe de protons

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Rodrigo Luis da

    2007-07-01

    In earliest works devoted to proton computed tomography it was shown that the advantage of pCT image reconstruction appears when the energy is close to the Bragg peak region, since the proton passes the object. This effect provided by the Bragg peak makes the computerized tomography with protons possible. However, when decreasing the initial proton energy, with the increase of the irradiation dose, there are two effects that work simultaneously in opposite ways. First, the energy loss of a proton in an object becomes bigger at small initial energy. At the same time decreasing of the proton energy results in the increase of the energy straggling, requiring a larger number of protons. In this work the radiation dose dependence on the proton initial energy was studied using analytical formulas and computer simulations. The investigation determined that the radiation dose practically does not depend on the initial energy, except in the energy region very close to the minimum energy necessary to pass the object. (author)

  4. Impacto do polimorfismo genetico da enzima conversora da angiotensina no remodelamento cardiaco

    Directory of Open Access Journals (Sweden)

    Felipe Neves de Albuquerque

    2014-01-01

    Full Text Available Fundamento: O papel dos polimorfismos genéticos da enzima de conversão da angiotensina na insuficiência cardíaca, como preditor de desfechos ecocardiográficos, ainda não está estabelecido. é necessário identificar o perfil local para observar o impacto desses genótipos na população brasileira, sendo inédito o estudo da insuficiência cardíaca de etiologia exclusivamente não isquêmica em seguimento mais longo que 5 anos. Objetivo: Determinar a distribuição das variantes do polimorfismo genético da enzima de conversão da angiotensina e sua relação com a evolução ecocardiográfica de pacientes com insuficiência cardíaca de etiologia não isquêmica. Métodos: Análise secundária de prontuários de 111 pacientes e identificação das variantes do polimorfismo genético da enzima de conversão da angiotensina, classificadas como DD (Deleção/Deleção, DI (Deleção/Inserção ou II (Inserção/Inserção. Resultados: As médias da coorte foram: seguimento de 64,9 meses, idade de 59,5 anos, 60,4% eram homens, 51,4% eram brancos, 98,2% faziam uso de betabloqueadores e 89,2% de inibidores da enzima de conversão da angiotensina ou de bloqueador do receptor da angiotensina. A distribuição do polimorfismo genético da enzima de conversão da angiotensina foi: 51,4% de DD; 44,1% de DI; e 4,5% de II. Não se observou nenhuma diferença das características clínicas ou de tratamento entre os grupos. O diâmetro sistólico do ventrículo esquerdo final foi a única variável ecocardiográfica isolada significativamente diferente entre os polimorfismos genéticos da enzima de conversão da angiotensina: 59,2 ± 1,8 para DD versus 52,3 ± 1,9 para DI versus 59,2 ± 5,2 para II (p = 0,029. No seguimento ecocardiográfico, todas as variáveis (diferença entre a fração de ejeção do ventrículo esquerdo da última e da primeira consulta; diferença entre o diâmetro sistólico do ventrículo esquerdo da última e da primeira

  5. "Geografia da Fome": da lógica regional à universalidade

    Directory of Open Access Journals (Sweden)

    Arruda Bertoldo Kruse Grande de

    1997-01-01

    Full Text Available Geografia da Fome revela a associação harmoniosa da capacidade de argumentar com a segurança científica, um novo modo de pensar e de agir frente à realidade alimentar e nutricional e também uma abordagem pioneira no dimensionamento da fome coletiva como um fenômeno geograficamente universal. Admitiu, com base nas especificidades regionais, que as contribuições parciais poderiam compor um mapeamento caracterizador da universalidade do problema, permitindo construir uma imagem diferente do Brasil e do mundo, possibilitando a estruturação de um plano universal de combate à fome, abrindo novos caminhos para aqueles que buscam a correção de desequilíbrios regionais e a eliminação do subdesenvolvimento. Nesse livro-manifesto, Josué de Castro reinterpretou o papel da geografia clássica, incorporando uma das dimensões explicativas mais importantes, que é a da análise política, para desvendar a significação e conseqüências do desenvolvimento espacial desigual. A releitura de Geografia da Fome mostra que seus delineamentos conceituais e propositivos continuam vivos e constituem instrumentos indispensáveis para repensar criticamente a realidade brasileira e, em particular, a nordestina. Geografia da Fome, no seu cinqüentenário, torna-se um livro atual pela sua mensagem estimuladora e perturbadora.

  6. "Geografia da Fome": da lógica regional à universalidade

    Directory of Open Access Journals (Sweden)

    Bertoldo Kruse Grande de Arruda

    1997-09-01

    Full Text Available Geografia da Fome revela a associação harmoniosa da capacidade de argumentar com a segurança científica, um novo modo de pensar e de agir frente à realidade alimentar e nutricional e também uma abordagem pioneira no dimensionamento da fome coletiva como um fenômeno geograficamente universal. Admitiu, com base nas especificidades regionais, que as contribuições parciais poderiam compor um mapeamento caracterizador da universalidade do problema, permitindo construir uma imagem diferente do Brasil e do mundo, possibilitando a estruturação de um plano universal de combate à fome, abrindo novos caminhos para aqueles que buscam a correção de desequilíbrios regionais e a eliminação do subdesenvolvimento. Nesse livro-manifesto, Josué de Castro reinterpretou o papel da geografia clássica, incorporando uma das dimensões explicativas mais importantes, que é a da análise política, para desvendar a significação e conseqüências do desenvolvimento espacial desigual. A releitura de Geografia da Fome mostra que seus delineamentos conceituais e propositivos continuam vivos e constituem instrumentos indispensáveis para repensar criticamente a realidade brasileira e, em particular, a nordestina. Geografia da Fome, no seu cinqüentenário, torna-se um livro atual pela sua mensagem estimuladora e perturbadora.

  7. Influência da nutrição mineral foliar sobre doenças da parte aérea da cultura do trigo

    Directory of Open Access Journals (Sweden)

    Rafael Gustavo Ferreira Morales

    2012-02-01

    Full Text Available A utilização de fungicida para o controle de doenças foliares na cultura do trigo é prática comum entre os triticultores. Contudo, devido ao impacto ambiental provocado pelo seu uso generalizado, buscam-se alternativas para controle dos fitopatógenos. Sendo assim, este trabalho teve como objetivo avaliar o efeito da nutrição mineral foliar sobre as doenças foliares do trigo, bem como seu efeito sobre o desenvolvimento da planta. O delineamento experimental foi em blocos casualizados com quatro repetições e quatro tratamentos: 1- testemunha; 2- adubação foliar aos 30 dias após a emergência (DAE e aos 75 DAE; 3- fungicida aos 30 e 75 DAE; e 4- adubação foliar aos 30 DAE e adubação foliar mais fungicida aos 75 DAE. Foram realizadas nove avaliações da incidência e da severidade do oídio, cujos dados foram utilizados para o cálculo das áreas abaixo das curvas de progresso da doença; três avaliações da severidade da ferrugem e da mancha da gluma; e duas avaliações da mancha amarela. Foram determinadas a massa de matéria fresca e seca da parte aérea e do sistema radicular e a produtividade da cultura. Foi observada redução da incidência e da severidade de oídio em função da adubação foliar, apenas na primeira avaliação de incidência e nas segunda e quinta avaliações de severidade da doença. O efeito complementar dos nutrientes com o fungicida para redução das doenças foi observado apenas para a mancha amarela, com redução de aproximadamente 11,16 % da severidade. Os maiores valores de produtividade foram observados para os tratamentos apenas com fungicida e, com fungicida mais nutrientes. A adubação foliar proporcionou aumento da massa fresca de raízes e massa seca de raízes. Apesar disso, não houve aumento da massa fresca da parte aérea em função da adubação foliar.

  8. Efficacy of 3D-positron emission tomography/computed tomography for upper abdomen.

    Science.gov (United States)

    Murakami, Koji; Nakahara, Tadaki

    2014-04-01

    Recent advancement in computed tomography (CT) enables us to obtain high spatial resolution image and made it possible to construct extensive high-definition three-dimensional (3D) images. But a lack of contrast resolution in CT alone is still remained problem. Meanwhile, as fluorodeoxyglucose-positron emission tomography (PET) can visualize tumors in high contrast, we can create 3D images fusing the accumulation in tumors on PET/CT images. Such images can play the role of a "map of body" which makes it easy to understand the anatomical information before surgery. We also try to evaluate segmental liver function by using PET/CT fusion images. By using (11) C-methionine PET/contrast-enhanced CT, superior image quality compared to single photon emission computed tomography/CT can be obtained. CT, especially with contrast enhancement for obtaining anatomical imaging information plus PET for obtaining functional imaging information is a highly compatible combination, and adding these two types information will further increase clinical usefulness. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  9. A aplicação dos recursos da seguridade social, a partir da perspectiva da teoria dos sistemas, da teoria comunicacional e do caos

    OpenAIRE

    Júnior, Dávio Antonio Prado Zarzana

    2011-01-01

    Este trabalho, focalizando o custeio da Seguridade Social, pretende realizar três verificações: a primeira, a existência ou não de desvios na aplicação dos recursos arrecadados para este financiamento, inclusive a partir da formulação de um conceito de desvio. A segunda, examinar os desequilíbrios que esses possíveis desvios produziriam, sob a ótica da Teoria dos Sistemas, utilizando-se, em adição, terminologia própria da Teoria Comunicacional. E a terceira, perscrutar a pos...

  10. Paradoxical emboli: demonstration using helical computed tomography of the pulmonary artery associated with abdominal computed tomography

    International Nuclear Information System (INIS)

    Delalu, P.; Ferretti, G.R.; Bricault, I.; Ayanian, D.; Coulomb, M.

    2000-01-01

    We report the case of a 60-year-old woman with a recent history of a cerebrovascular accident. Because of clinical suspicion of pulmonary embolism and negative Doppler ultrasound findings of the lower limbs, spiral computed tomography of the pulmonary artery was performed and demonstrated pulmonary emboli. We emphasize the role of computed tomography of the abdomen, performed 3 min after the thoracic acquisition, which showed an unsuspected thrombus within the abdominal aorta and the left renal artery with infarction of the left kidney. Paradoxical embolism was highly suspected on computed tomography data and confirmed by echocardiography which demonstrated a patent foramen ovale. (orig.)

  11. Contrast-enhanced fluorodeoxyglucose positron emission tomography/contrast-enhanced computed tomography in mediastinal T-cell lymphoma with superior vena cava syndrome

    International Nuclear Information System (INIS)

    Santhosh, Sampath; Gorla, Arun Kumar Reddy; Bhattacharya, Anish; Varma, Subhash Chander; Mittal, Bhagwant Rai

    2016-01-01

    Positron emission tomography-computed tomography (PET/CT) is a routine investigation for the staging of lymphomas. Contrast-enhanced computed tomography is mandatory whenever parenchymal lesions, especially in the liver and spleen are suspected. We report a rare case of primary mediastinal T-cell lymphoma evaluated with contrast-enhanced PET/CT that showed features of superior vena cava syndrome

  12. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  13. Origin of the DA and non-DA white dwarf stars

    Science.gov (United States)

    Shipman, Harry L.

    1989-01-01

    Various proposals for the bifurcation of the white dwarf cooling sequence are reviewed. 'Primordial' theories, in which the basic bifurcation of the white dwarf sequence is rooted in events predating the white dwarf stage of stellar evolution, are discussed, along with the competing 'mixing' theories in which processes occurring during the white dwarf stage are responsible for the existence of DA or non-DA stars. A new proposal is suggested, representing a two-channel scenario. In the DA channel, some process reduces the hydrogen layer mass to the value of less than 10 to the -7th. The non-DA channel is similar to that in the primordial scenario. These considerations suggest that some mechanism operates in both channels to reduce the thickness of the outermost layer of the white dwarf. It is also noted that accretion from the interstellar medium has little to do with whether a particular white dwarf becomes a DA or a non-DA star.

  14. Várias Marias: efeitos da Lei Maria da Penha nas delegacias

    Directory of Open Access Journals (Sweden)

    Roberta Carvalho Romagnoli

    2015-08-01

    Full Text Available Este artigo discute os dados qualitativos da pesquisa “Violência Doméstica perpetrada contra a mulher no município de Montes Claros: um recorte possível”, financiada pelo CNPq e pela FAPEMIG. O objetivo do estudo foi investigar quantitativamente e qualitativamente os atos violentos contra as mulheres na cidade de Montes Claros, Minas Gerais. A vertente qualitativa pretendia conhecer o sentido da violência para as mulheres envolvidas e seus reflexos na família, através de entrevistas semiestruturadas que não se efetivaram. A partir da Análise Institucional de René Lourau analisamos essa inviabilidade como dado qualitativo, examinando o cotidiano da delegacia após a lei Maria da Penha. Concluímos que a intervenção judicial não é suficiente para a inibição da violência contra a mulher, pois em certos casos afasta da delegacia mulheres com outras demandas acerca da violência, que sofrem e que não podem contar com a ajuda policial para a resolução dos seus conflitos.

  15. Promising role of single photon emission computed tomography/computed tomography in Meckel's scan

    International Nuclear Information System (INIS)

    Jain, Anurag; Chauhan, MS; Pandit, AG; Kumar, Rajeev; Sharma, Amit

    2012-01-01

    Meckel's scan is a common procedure performed in nuclear medicine. Single-photon emission computed tomography/computed tomography (SPECT/CT) in a suspected case of heterotopic location of gastric mucosa can increase the accuracy of its anatomic localization. We present two suspected cases of Meckel's diverticulum in, which SPECT/CT co-registration has helped in better localization of the pathology

  16. Implicações da visibilidade da enfermagem no exercício profissional

    Directory of Open Access Journals (Sweden)

    Liziani Iturriet Avila

    Full Text Available A construção da imagem da Enfermagem é permeada por aspectos históricos, socioeconômicos e culturais. Ao explorar esta temática, objetivou-se conhecer a percepção dos enfermeiros acerca da visibilidade do cotidiano de trabalho da equipe de enfermagem. Pesquisa qualitativa do tipo exploratória, com 30 enfermeiros de um hospital universitário do sul do país. Os dados foram coletados, de julho a outubro de 2012, através de entrevista semi-estruturada e submetidos à análise textual discursiva. Os resultados apontam que a visibilidade da Enfermagem está relacionada à trajetória histórica da profissão, à falta de reconhecimento da cientificidade da Enfermagem, à veiculação errônea na mídia, aos comportamentos inadequados perante a equipe e, ainda, à sobrecarga de trabalho. Assim, a desmistificação da imagem da profissão inclui uma busca de maior visibilidade midiática, realização de marketing pessoal, comportamento adequado perante a equipe de saúde e demonstração de autonomia profissional, desafios estes que deverão ser superados pela Enfermagem.

  17. An update in proton probe tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sakellariou, A.; Cholewa, M.; Saint, A.; Legge, G.L.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Howard, J. [Australian National Univ., Canberra, ACT (Australia). Research School of Physical Sciences

    1996-12-31

    The analysis of scanning transmission ion microscopy (STIM) tomography data is improved. The volumetric density information is obtained directly from an iterative convolution and back-projection (BFP) reconstruction method. The iterative method allows the effects of stopping-power to be incorporated easily. One draw back is that a priori constituency information is required for the iterative method to work However, this is of no concern because the iterative method was designed with PIXE tomography in mind. In this light, the a priori information will be obtained as the zeroth iteration of a PIXE tomography iterative reconstruction method. 4 refs., 1 tab., 4 figs.

  18. An update in proton probe tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sakellariou, A; Cholewa, M; Saint, A; Legge, G L.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Howard, J [Australian National Univ., Canberra, ACT (Australia). Research School of Physical Sciences

    1997-12-31

    The analysis of scanning transmission ion microscopy (STIM) tomography data is improved. The volumetric density information is obtained directly from an iterative convolution and back-projection (BFP) reconstruction method. The iterative method allows the effects of stopping-power to be incorporated easily. One draw back is that a priori constituency information is required for the iterative method to work However, this is of no concern because the iterative method was designed with PIXE tomography in mind. In this light, the a priori information will be obtained as the zeroth iteration of a PIXE tomography iterative reconstruction method. 4 refs., 1 tab., 4 figs.

  19. Reinforced concrete tomography

    International Nuclear Information System (INIS)

    Mariscotti, M.A.J.; Morixe, M.; Tarela, P.A.; Thieberger, P.

    1997-01-01

    In this paper we describe the technique of reinforced concrete tomography, its historical background, recent technological developments and main applications. Gamma radiation sensitive plates are imprinted with radiation going through the concrete sample under study, and then processed to reveal the presence of reinforcement and defects in the material density. The three dimensional reconstruction, or tomography, of the reinforcement out of a single gammagraphy is an original development alternative to conventional methods. Re-bar diameters and positions may be determined with an accuracy of ± 1 mm 0.5-1 cm, respectively. The non-destructive character of this technique makes it particularly attractive in cases of inhabited buildings and diagnoses of balconies. (author) [es

  20. 4-[[sup 123]I]iodospiperone as a ligand for dopamine DA receptors: in vitro and in vivo experiments in a rat model

    Energy Technology Data Exchange (ETDEWEB)

    Krogt, J.A. van der; Valkenburg, C F.M. van; Pauwels, E K.J.; Buruma, O J.S. [Rijksuniversiteit Leiden (Netherlands); Reiffers, S [Hospital De Weezenlanden, Zwolle (Netherlands); Doremalen, P.A.P.M. van; Wijnhoven, G [Cygne, Eindhoven (Netherlands)

    1992-10-01

    Radioiodinated spiperone is of interest for dopamine (DA) receptor studies in the living human brain by single photon emission computed tomography (SPECT). Simulated by data obtained with [[sup 11]C]-N-methyl-spiperone, we synthesized 4-[[sup 123]I]iodospiperone and investigated the in vitro binding characteristics of this ligand to the striatal membrane of the rat and the in vivo distribution over various rat brain regions. The in vitro binding experiments showed that this radioligand displays about 10 times less affinity for the DA receptor than spiperone and specific binding, as shown with [[sup 3]H]spiperone, was not observed. Displacement by butaclamol was not observed. The in vivo studies demonstrated that both 4-[[sup 123]I]iodospiperone and [[sup 3]H]spiperone concentrate in striatal tissue, respectively, 1.9 and 3.5 times as high as in cerebellar tissue. Haloperidol pretreatment largely prevented this accumulation. In view of the obtained target-to-non-target ratios we believe, however, that this accumulation in brain areas rich DA-receptors does not offer prospects for clinical receptor imaging with SPECT. (Author).

  1. Hanna Krall e os caminhos tortos da memória e da identidade

    OpenAIRE

    Piotr Kilanowski

    2013-01-01

    Neste artigo apresentamos a escritora polonesa de origem judaica Hanna Krall por meio da análise literária do seu romance Sublokatorka (A sublocatária).  O romance, com elementos autobiográficos, apresenta a personalidade cindida de uma menina sobrevivente do Holocausto e discute o tema da identidade polonesa, judaica e judaico-polonesa. Através da observação da memória e do processo de criação da memória, a autora mostra a construção da identidade falsa e a repressão da verdadeira, o comport...

  2. Direito à palavra: interrogações acerca da proposta da justiça restaurativa

    Directory of Open Access Journals (Sweden)

    Edson Luiz André de Sousa

    Full Text Available Partindo da constatação da necessidade de alternativas ao sistema de Justiça atual, o presente artigo objetiva dar voz a uma das propostas que vem ganhando força no cenário jurídico mundial: a Justiça Restaurativa. Para tanto, este artigo explora essa proposta, promovendo uma análise crítica amparada em autores da psicanálise (freudo-lacaniana e da Filosofia (com F. Ost e J. Derrida. Através da Justiça Restaurativa, é possível questionar a potência da circulação da palavra, característica que promove o tensionamento entre psicanálise e Direito. Além disso, a questão da Lei e das leis, da performatividade dos atos da fala, da posição do Juiz, da experiência do encontro restaurativo e da função das utopias são os principais vieses que compõem esta análise. Mais voltado para a possibilidade de anunciar questionamentos sobre essa proposta tão nova no contexto brasileiro do que de encontrar respostas satisfatórias, este artigo mantém em suspenso várias conclusões, embora assuma a constatação da importante função utópica da Justiça Restaurativa.

  3. Cruzeiros marítimos: realidade da oferta e da demanda no mercado brasileiro

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo de Almeida Ramoa

    2014-12-01

    Full Text Available O turismo marítimo apresenta uma demanda crescente e constante nos Estados Unidos e na Europa. No Brasil, esse mercado vinha se destacando com crescimento exponencial da demanda, no entanto, a partir da temporada 2011/2012 a taxa de crescimento tem apresentado queda. Este estudo de caráter exploratório e descritivo utiliza o método de procedimento matemático e tem como objetivo geral identificar a realidade da oferta e da demanda no mercado brasileiro de cruzeiros marítimos. Para atingi-lo foram identificados os históricos da oferta e da demanda, no período de 2004 a 2013, e da situação atual da infraestrutura portuária, através da utilização de técnicas de documentação indireta, procedimento documental e bibliográfico. Para se comparar a taxa de crescimento do mercado brasileiro com os principais mercados foi realizado cálculo da extrapolação matemática exponencial. Os resultados apresentados indicam que o Brasil é o único país entre os dez maiores mercados de cruzeiros marítimos, que possui taxa de crescimento negativo, indicando haver uma crise no segmento de cruzeiros marítimos, cujo motivo aponta para os problemas estruturais como sendo uma das causas da queda da oferta e da demanda no mercado brasileiro.

  4. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19,2016 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  5. Fundamentals for routined utilization of tomography in beam diagnostic

    International Nuclear Information System (INIS)

    Reichau, Hermine

    2012-01-01

    A general and systematic approach to implement tomography for beam diagnostics has been invented and exemplarily shown for the invention of beam tomography for the Frankfurt Neutron Source. Following the diagnostic pipeline the first step was to prepare the data basis for the tomography reconstruction. For the monitoring, standard parameters have to be obtained with sufficient accuracy. In the context of this work, tomography has been kept as flexible as possible. Firstly, it will be used for the analysis of beam dynamics but also for the further development of beam tomography for routined utilization. Later on it will have to serve as a monitoring system at the end of the LEBT of FRANZ. The data preparation for tomography was demonstrated step by step. The iterated backprojection (FBP) algorithm was derived to show the basic idea of tomography which is contained in all forms of tomography algorithms. In connection with data exhibiting a high signal to noise ratio the FBP obtains the result with the highest accuracy, beyond that the accuracy can be controlled by the number of projections. The algebraic reconstruction and maximum entropy approach were outlined in a nutshell. By the introduction of the diagnostic pipeline in combination with the decision systematics the basis for a routined utilization of tomography in ion beam diagnostics have been established and exemplarily demonstrated on the introduction of beam tomography for FRANZ. A rotatable vacuum chamber has been developed to close a gap between the availability of projections to use the FBP and the small physical space on which they have to be determined. (orig.)

  6. ESTATUTO PARADOXAL DA PELE E CULTURA CONTEMPORÂNEA: da porosidade à pele-teflon

    Directory of Open Access Journals (Sweden)

    Maria Cristina Franco Ferraz

    2014-06-01

    Full Text Available A exploração do estatuto paradoxal da pele - interface dentro/fora - permite ultrapassar a dicotomia metafísica superfície/profundidade, problematizando a tendência atual, também expressa na teoria, a um elogio das superfícies e a um horror por oposições dicotômicas. Possibilta avaliar as implicações do fechamento da porosidade da pele em formas de sociabilidade estimuladas na cultura da imagem, da exibição, do espetáculo, bem expressas pelo material inorgânico teflon. Sendo Poros, na visão grega, pai de Eros, a investigação acerca do estatuto paradoxal da pele convida a uma retomada do tema do erotismo. Partindo de perspectivas oferecidas por Agamben acerca da pornografia, ligada ao valor de exibição nas sociedades de espetáculo e de consumo, e relacionando-as a diversas reflexões de José Gil acerca do corpo e da pele, discute-se e convoca-se a abertura da porosidade da pele.

  7. ANÁLISE DA PAISAGEM DA BACIA HIDROGRÁFICA DO RIO ALMADA (BA COM BASE NA FRAGMENTAÇÃO DA VEGETAÇÃO

    Directory of Open Access Journals (Sweden)

    Maria Eugênia Bruck de Moraes

    2012-04-01

    Full Text Available O estudo da fragmentação da paisagem em uma bacia é de extrema importância por avaliar o status de conservação da vegetação, um recurso essencial para a manutenção da qualidade da água. O presente trabalho apresenta uma análise da fragmentação da paisagem na Bacia Hidrográfica do Rio Almada, localizada no sul da Bahia, abrangendo 9 municípios parcialmente abastecidos pela água desta bacia. Foi realizado o mapeamento dos fragmentos florestais que apresentaram área mínima de 3ha, com base na interpretação da Carta de Uso e Cobertura do Solo elaborada através da classificação supervisionada de imagens Landsat. Para a análise dos fragmentos foram adotadas 5 métricas da paisagem: tamanho, formato, efeito de borda, isolamento e conectividade. Os resultados obtidos demonstram que a BHRA ainda abriga fragmentos bastante representativos, visto que dos 58 fragmentos identificados, 8 têm área acima de 300ha, 20 entre 100 e 300ha, 21 entre 30 e 100ha e 9 entre 3 e 30ha. Com relação ao formato dos fragmentos, constatou-se que apenas 10% dos mesmos apresentam forma circular, indicando que os 90% restantes encontram-se susceptíveis ao efeito de borda, sendo que os mais alongados estão localizados no interior da bacia, provavelmente em função do avanço da pecuária extensiva nessa direção. E quanto ao isolamento dos fragmentos, a análise da conectividade com borda expandida, através de simulações, permitiu identificar que a partir da distância de 200m, 31 dos fragmentos poderiam ser conectados. Assim, pôde-se concluir que o somatório destes fragmentos, caso fossem devidamente conectados, representaria uma área de significativo valor para a conservação de espécies típicas da mata atlântica e, consequentemente, para a manutenção da qualidade da água desta bacia.

  8. Introducing passive matched field acoustic tomography

    International Nuclear Information System (INIS)

    Gasparini, O.; Camporeale, C.; Crise, A.

    1997-01-01

    In acoustic tomography sea-basin environmental parameters such as temperature profiles and current-velocities are derived, when ray propagation models are adopted, by the travel time estimates relative to the identifiable ray paths. The transmitted signals are either single frequency, or impulsive, or intermittent and deterministic. When the wavelength is comparable with the scale lengths present in the propagation scenario, Matched Field Tomography (MFT) is used, entailing the consideration of waveguide modes instead of rays. A new concept in tomography is introduced in the paper, that employs passively the noise emitted by ships of opportunity (cargoes, ferries) as source signals. The passive technique is acoustic-pollution-free, and if a basin is selected in which a regular ship traffic occurs data can be received on a regular schedule, with no transmission cost. A novel array pre-processor for passive tomography is introduced, such that the signal structure at the pre-processor output in nearly the same as that obtainable in the case of single-frequency source signals

  9. ANÁLISE OPERACIONAL DA COLHEITA FLORESTAL NO SUL DA BAHIA

    OpenAIRE

    CARMO, F. C. A.

    2013-01-01

    CARMO, Flávio Cipriano de Assis. Análise operacional da colheita florestal no sul da Bahia. 2013. Dissertação (Mestrado em Ciências Florestais) Universidade Federal do Espírito Santo, Jerônimo Monteiro-ES. Orientador: Prof. Dr. Nilton César Fiedler. Coorientador: Profª. Drª. Elizabeth Neire da Silva Oliveira de Paula. Objetivou-se com esta pesquisa realizar uma análise operacional das atividades de colheita florestal em plantios de eucalipto no sul da Bahia. No estudo foram avaliados os ...

  10. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  11. ESTIMAÇÃO DA IDADE DA REGENERAÇÃO DA VEGETAÇÃO DE CERRADO A PARTIR DE IMAGENS LANDSAT

    Directory of Open Access Journals (Sweden)

    Philippe Maillard, Priscilla S. Costa-Pereira

    2011-07-01

    Full Text Available Nas regiões em que a rede de monitoramento hidrossedimentológico é precária ou inexistente, a utilização de modelos hidrológicos, de base física que proporcionem estimativas da geração de escoamento superficial e a perda de solo, se torna muito útil para fins de planejamento das bacias hidrográficas. O presente trabalho trata da aplicação do modelo hidrossedimentológico “Soil And Water Assessment Tool” nas Sub-Bacias 2 e 1 da Bacia Experimental de São João do Cariri. O modelo com a interface ArcSWAT, que se une ao SIG, necessita da entrada de “Modelo Digital de Elevação” (MDE da bacia e as simulações foram realizadas utilizando dois MDEs para fins de análise comparativa: um originado a partir da interpolação de dados de campo e outro obtido através de sensoriamento remoto. Com isto foi possível verificar a confiabilidade do uso de MDE obtido por sensoriamento remoto. Em nível das sub-bacias experimentais, foi realizada a parametrização, na Sub-Bacia 2, e a validação, na Sub-Bacia 1. O desempenho do modelo, para a geração da lâmina escoada, foi avaliado pelo coeficiente de determinação (R² e do fator da eficiência de Nash-Sutcliffe. Os resultados mostram desempenho satisfatório para ambos os MDEs, mostrando a pouca sensibilidade da topografia da geração de lâmina simulada em pequenas bacias. Por outro lado, a produção de sedimentos apresentou resultados insatisfatórios, além do que foi significativa a discrepância da distribuição da erosão do solo na superfície da bacia pelos dois MDEs utilizados.

  12. COMPORTAMENTO DA ARRECADAÇÃO PRÓPRIA E DA CARGA TRIBUTÁRIA NOS MUNICÍPIOS DA ZONA DA MATA MINEIRA

    Directory of Open Access Journals (Sweden)

    Anderson de Oliveira Reis

    2016-06-01

    Full Text Available O processo de descentralização consolidado pela constituição de 1988 mudou a dinâmica do federalismo brasileiro aumentando as receitas disponíveis e também as responsabilidades do fornecimento de serviços para os municípios, que em termos financeiros são muito dependentes das transferências governamentais. Diante da importância dos municípios na Administração Pública como entes federativos, este estudo tem como objetivo identificar, a partir da classificação em grupos, a mudança no perfil da arrecadação tributária própria dos municípios da Zona da Mata Mineira tendo por base os períodos de 2005 e 2010. Trata-se de pesquisa descritiva e quantitativa em que se utilizou as metodologias de Análise de Cluster e Teste t para amostras emparelhadas. Os resultados apontam para formação de 4 grupos de acordo com o esforço fiscal (baixo, médio e alto. Em média observa-se uma evolução positiva na arrecadação própria dos municípios que foi confirmada pelo Teste t. Conclui-se que apesar da dependência dos recursos de transferências, os municípios têm realizados esforços para aumentar a arrecadação própria e consequentemente suas receitas disponíveis.

  13. Synthesis and evaluation of translocator 18 kDa protein (TSPO) positron emission tomography (PET) radioligands with low binding sensitivity to human single nucleotide polymorphism rs6971.

    Science.gov (United States)

    Zanotti-Fregonara, Paolo; Zhang, Yi; Jenko, Kimberly J; Gladding, Robert L; Zoghbi, Sami S; Fujita, Masahiro; Sbardella, Gianluca; Castellano, Sabrina; Taliani, Sabrina; Martini, Claudia; Innis, Robert B; Da Settimo, Federico; Pike, Victor W

    2014-10-15

    The imaging of translocator 18 kDa protein (TSPO) in living human brain with radioligands by positron emission tomography (PET) has become an important means for the study of neuroinflammatory conditions occurring in several neuropsychiatric disorders. The widely used prototypical PET radioligand [(11)C](R)-PK 11195 ([(11)C](R)-1; [N-methyl-(11)C](R)-N-sec-butyl-1-(2-chlorophenyl)-N-methylisoquinoline-3-carboxamide) gives a low PET signal and is difficult to quantify, whereas later generation radioligands have binding sensitivity to a human single nucleotide polymorphism (SNP) rs6971, which imposes limitations on their utility for comparative quantitative PET studies of normal and diseased subjects. Recently, azaisosteres of 1 have been developed with improved drug-like properties, including enhanced TSPO affinity accompanied by moderated lipophilicity. Here we selected three of these new ligands (7-9) for labeling with carbon-11 and for evaluation in monkey as candidate PET radioligands for imaging brain TSPO. Each radioligand was readily prepared by (11)C-methylation of an N-desmethyl precursor and was found to give a high proportion of TSPO-specific binding in monkey brain. One of these radioligands, [(11)C]7, the direct 4-azaisostere of 1, presents many radioligand properties that are superior to those reported for [(11)C]1, including higher affinity, lower lipophilicity, and stable quantifiable PET signal. Importantly, 7 was also found to show very low sensitivity to the human SNP rs6971 in vitro. Therefore, [(11)C]7 now warrants evaluation in human subjects with PET to assess its utility for imaging TSPO in human brain, irrespective of subject genotype.

  14. Evaluation of brain scintigraphy and computerized tomography

    International Nuclear Information System (INIS)

    Cavailloles, F.; Dairou, R.; Desbleds, M.T.; Benoit, C.; Larmande, P.; Bok, B.; Alperovitch, A.

    1983-01-01

    In order to assess the clinical usefulness of brain computerized tomography and radionuclide scan, a prospective study was performed on a series of 554 patients. The detection rate was assessed as well as the identification rate of lesions. In addition, the usefulness of both tests was appreciated subjectively by two neurologists reviewing the patients' files. Both give reasonably similar results: computerized tomography is superior to radionuclide scan in the diagnosis of tumors and intracerebral hematomas, the radionuclide scan being slightly superior in the diagnosis of purely ischemic CVA and subdural hematomas. The superiority which was subjectively conceded to computerized tomography was greater than that objectively demonstrated. However, clinical usefulness of computerized tomography was judged important in only 50% of the cases. Moreover, to request both computerized tomography and radionuclide scan appeared as having no interest in 83% of the cases. In that series, the diagnostic hypotheses were in agreement with the final diagnosis in 88% of the cases. Bias encountered in this type of studies are discussed [fr

  15. Computerized tomography in myotonic dystrophy

    International Nuclear Information System (INIS)

    Gellerich, I.; Mueller, D.; Koch, R.D.

    1986-01-01

    Besides clinical symptoms, progress and electromyography computerized tomography improves the diagnostics of myotonic dystrophy. Even small changes in muscular structure are detectable and especially the musculus soleus exhibits early and pronounced alterations. By means of density distribution pattern an improved characterization of the disease is possible. Additional information is obtained by cerebral computerized tomography. Atrophy of brain tissue is to be expected in all patients with myotonic dystrophy. (author)

  16. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Kretschmann, H.J.; Weinrich, W.

    1985-01-01

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  17. IMPLICAÇÕES DA ANÁLISE V-A-T DA TEORIA DAS RESTRIÇÕES NA GESTÃO DA CADEIA DE SUPRIMENTOS

    Directory of Open Access Journals (Sweden)

    Diego Augusto de Jesus Pacheco

    2016-03-01

    Full Text Available O objetivo dessa pesquisa é identificar o impacto da análise V-A-T da Teoria das Restrições na gestão estratégica de materiais à luz da Matriz de Posicionamento Estratégico dos Materiais (MPEM. A partir de dois estudos de caso, buscou-se verificar: i em qual classificação cada empresa se enquadrava dentro da lógica V-A-T, e ii se a gestão estratégica de materiais a partir da abordagem da MPEM pode ser considerada semelhante ou não nos casos investigados. Os resultados da pesquisa apontaram que a classificação V-A-T no caso da empresa S é do tipo A e no caso da empresa K é do tipo V. Já a análise da gestão estratégica de materiais a partir da MPEM, evidenciou que no caso S pertence ao quadrante não crítico e no caso K pertence ao quadrante estratégico. Identificou-se que a classificação V-A-T tende a impactar na gestão de materiais e no controle de estoques.

  18. Influência da idade da planta e da maturação dos frutos no momento da colheita na qualidade do café

    OpenAIRE

    Borges,Fernanda Barbosa; Jorge,José Tadeu; Noronha,Regina

    2002-01-01

    São de grande importância os cuidados no preparo do café desde a colheita até o consumo e o estudo de parâmetros que possam influenciar na classificação comercial do grão e na qualidade da bebida. Teve-se como objetivos analisar a influência da idade das plantas, pertencentes à mesma variedade, e dos estágios de maturação dos grãos (secos, cerejas e verdes) no resultado da classificação comercial e na qualidade da bebida. Realizou-se a colheita, por derriça no pano, de uma área com café arábi...

  19. A decomposição do Estado e o protagonismo da sociedade civil no enfrentamento da questão social no Brasil: os dilemas da cidadania e da democracia na contemporaneidade

    Directory of Open Access Journals (Sweden)

    Freire, Silene de Moraes

    2006-01-01

    Full Text Available O presente artigo foi elaborado a partir de preocupações profissionais voltadas para desvelar a presença e o enfrentamento, por parte do Estado e da sociedade civil, da questão social no cenário histórico-cultural da sociedade brasileira, evidenciado a partir da década de noventa, sobretudo, quando observamos a guinada do Estado brasileiro para a “mentalidade privatizante” que as reformas estruturais de cunho neoliberal promoveram. No caso brasileiro, tal projeto reafirma uma das particularidades de nossa cultura política: o moderno se constitui por meio do “arcaico”, recriando nossa herança histórica ao atualizar aspectos persistentes e, ao mesmo tempo, transformando-os no contexto da globalização. Pretendemos, assim, discutir de que modo a permanência histórica da desigualdade social, dos limites da cidadania e da democracia serviram como elemento facilitador para a implementação da agenda neoliberal no Brasil

  20. Tumour screening by means of tomography methods

    International Nuclear Information System (INIS)

    Diederich, S.

    2005-01-01

    Tomography methods such as computer tomography (CT), magnetic resonance tomography (MRT), and sonography/ultrasound examinations make it possible to detect small asymptomatic tumours, thus potentially preventing their manifestation at an advanced stage and improving survival prospects for the patients concerned. There are data available on various common tumours which show that modern tomography methods are capable of detecting not only small asymptomatic tumours but also their benign precursors (e.g. polyps of the large intestine). This has been demonstrated for lung cancer, colon cancer and breast cancer. However, it has not been possible to date to show for any tomography method or any type of tumour that the systematic use of such diagnostic procedures does anything to lower the mortality rate for that tumour. For other types of tumour (pancreatic cancer, kidney cancer, ovary cancer) the above named methods are either not sufficiently sensitive or the body of data that has accumulated on their respective use is too small to judge the benefit of tomography screenings. Current technical developments make it appear probable that for many types of cancer the reliability with which small tumours can be detected will improve in future. Studies aimed at clarifying the potential of screenings for reducing mortality rates are already underway for lung cancer and would be worthwhile performing for other tumour types

  1. Aspectos macroepidemiológicos da esquistossomose mansônica: análise da relação da irrigação no perfil espacial da endemia no Estado da Bahia, Brasil

    Directory of Open Access Journals (Sweden)

    Martins Jr. Davi Félix

    2003-01-01

    Full Text Available Estudos na África, de forma enfática, têm mostrado a associação entre a implantação de perímetros de irrigação e o aumento ou expansão da ocorrência esquistossomose mansônica ou hematóbica. O objetivo deste estudo foi verificar a associação entre a prática de irrigação no território do Estado da Bahia e a ocorrência e a difusão da infecção pelo Schistosoma mansoni. O desenvolvimento da irrigação no Estado da Bahia assume duas formas: a primeira é intensiva em capital e mecanizada, voltada para produção agrícola de exportação e necessitando de pouca mão-de-obra. Na segunda forma, caracteriza-se pelo baixo grau de mecanização e utilização intensiva de mão-de-obra. O estudo mostrou que os municípios com as maiores áreas irrigadas não são aqueles que registram as mais altas taxas de prevalência da infecção. Na maior parte desses municípios a irrigação é intensiva em termos de capital e tecnologia. Os achados concluem que diferentemente do observado na África, no Estado da Bahia, a irrigação tem tido pequena influência na definição do perfil espacial da endemia.

  2. Da possibilidade de uma Teoria Pura da Ciência da Informação: reflexões iniciais entre a Ciência da Informação e a Ciência do Direito

    Directory of Open Access Journals (Sweden)

    Max Cirino de Mattos

    Full Text Available O artigo discute a fragilidade epistemológica da Ciência da Informação, a partir da adoção de um termo polissêmico, como objeto científico, e a similaridade dessa situação com o contexto da criação da Teoria Pura do Direito de Hans Kelsen. Após a apresentação de algumas definições sobre o objeto da Ciência da Informação, discutem-se alguns reflexos relacionados à identidade científica e à fundamentação teórica derivadas de um objeto polissêmico. Apresenta-se uma breve introdução à Teoria Pura do Direito e algumas reflexões sobre a possibilidade de uma Teoria Pura da Ciência da Informação.

  3. Computed tomography of the facial canal

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    The radiological details of the facial canal was investigated by computed tomography. In the first part of this study, dry skulls were used to delineate the full course of the facial canal by computed tomography. In the second part of this study, the patients with chronic otitis media and secondary cholesteatoma were evaluated. The labyrinthine and tympanic parts of the canal were well demonstrated with the axial scanning, and the mastoid part with the coronal scanning. Moreover, computed tomography showed excellent delineation of the middle ear contents. In patients with secondary cholesteatoma, the destructions of the intratympanic course of the bony facial canal were also assessed preoperatively. (author)

  4. Computed tomography of post-traumatic orbito-palpebral emphysema

    International Nuclear Information System (INIS)

    Nose, Harumi; Kohno, Keiko

    1981-01-01

    Two cases of orbito-palpebral emphysema are described. Both having a history of recent facial trauma, emphysema occurred after blowing the nose. They were studied by computed tomography and plain x-ray film, including tomograms of the orbit. The emphysema was revealed by computed tomography and x-ray film, but more clearly by the former technique. The fracture lines of the orbit were revealed in only one case by x-ray film, but in both cases by computed tomography. The authors stress that computed tomography is the best technique for the study of orbital emphysema. (author)

  5. F-18-fluorodeoxyglucose-positron emission tomography in colorectal cancer

    International Nuclear Information System (INIS)

    Joerg, L.; Langsteger, W.

    2002-01-01

    Whole-body positron emission tomography (PET) with the radiolabeled glucose analog F-18-fluorodeoxyglucose (F-18-FDG) is a sensitive diagnostic tool that images tumors based on increased uptake of glucose. Several recent publications have shown that F-18-fluorodeoxyglucose-positron emission tomography is more sensitive than computed-tomography (CT) in detecting colorectal cancer. In patients with increasing CEA (carcinoembryonic antigen) and no evidence of recurrent disease on CT F-18-fluorodeoxyglucose-positron emission tomography often detects recurrent cancer. In all, patient management seems to be changed in about 25 % of patients who undergo F-18-fluorodeoxyglucose-positron emission tomography in addition to standard staging procedure. Limited reports to date on both chemotherapy and radiotherapy support the role of F-18-fluorodeoxyglucose-positron emission tomography in assessing treatment response. Also regarding preoperative staging of primary colorectal cancer the literature is very limited. (author)

  6. Ceramic and polymeric dental onlays evaluated by photo-elasticity, optical coherence tomography, and micro-computed tomography

    Science.gov (United States)

    Sinescu, Cosmin; Negrutiu, Meda; Topala, Florin; Ionita, Ciprian; Negru, Radu; Fabriky, Mihai; Marcauteanu, Corina; Bradu, Adrian; Dobre, George; Marsavina, Liviu; Rominu, Mihai; Podoleanu, Adrian

    2011-10-01

    Dental onlays are restorations used to repair rear teeth that have a mild to moderate amount of decay. They can also be used to restore teeth that are cracked or fractured if the damage is not severe enough to require a dental crown. The use of onlays requires less tooth reduction than does the use of metal fillings. This allows dentists to conserve more of a patient's natural tooth structure in the treatment process. The aims of this study are to evaluate the biomechanical comportment of the dental onlays, by using the 3D photo elasticity method and to investigate the integrity of the structures and their fitting to the dental support. For this optical coherence tomography and micro-computed tomography were employed. Both methods were used to investigate 37 dental onlays, 17 integral polymeric and 20 integral ceramic. The results permit to observe materials defects inside the ceramic or polymeric onlays situate in the biomechanically tensioned areas that could lead to fracture of the prosthetic structure. Marginal fitting problems of the onlays related to the teeth preparations were presented in order to observe the possibility of secondary cavities. The resulted images from the optical coherence tomography were verified by the micro-computed tomography. In conclusion, the optical coherence tomography can be used as a clinical method in order to evaluate the integrity of the dental ceramic and polymeric onlays and to investigate the quality of the marginal fitting to the teeth preparations.

  7. The Comparison of Computed Tomography Perfusion, Contrast-Enhanced Computed Tomography and Positron-Emission Tomography/Computed Tomography for the Detection of Primary Esophageal Carcinoma.

    Science.gov (United States)

    Genc, Berhan; Kantarci, Mecit; Sade, Recep; Orsal, Ebru; Ogul, Hayri; Okur, Aylin; Aydin, Yener; Karaca, Leyla; Eroğlu, Atilla

    2016-01-01

    The purpose of this study was to investigate the efficiency of computed tomography perfusion (CTP), contrast-enhanced computed tomography (CECT) and 18F-fluoro-2-deoxy-D-glucose (18F-FDG) positron-emission tomography (PET/CT) in the diagnosis of esophageal cancer. This prospective study consisted of 33 patients with pathologically confirmed esophageal cancer, 2 of whom had an esophageal abscess. All the patients underwent CTP, CECT and PET/CT imaging and the imaging findings were evaluated. Sensitivity, specificity and positive and negative predictive values were calculated for each of the 3 imaging modalities relative to the histological diagnosis. Thirty-three tumors were visualized on CTP, 29 on CECT and 27 on PET/CT. Six tumors were stage 1, and 2 and 4 of these tumors were missed on CECT and PET/CT, respectively. Significant differences between CTP and CECT (p = 0.02), and between CTP and PET/CT (p = 0.04) were found for stage 1 tumors. Values for the sensitivity, specificity and positive and negative predictive values on CTP were 100, 100, 100 and 100%, respectively. Corresponding values on CECT were 93.94, 0, 93.94 and 0%, respectively, and those on PET/CT were 87.88, 0, 93.55 and 0%, respectively. Hence, the sensitivity, specificity and positive and negative predictive values of CTP were better than those of CECT and PET/CT. CTP had an advantage over CECT and PET/CT in detecting small lesions. CTP was valuable, especially in detecting stage 1 tumors. © 2016 S. Karger AG, Basel.

  8. A LEITURA DA GRAMÁTICA DA FORMA DO CONJUNTO HABITACIONAL CAMPINAS-F DA CDHU EM CAMPINAS

    Directory of Open Access Journals (Sweden)

    Marcelo de Morais

    2014-12-01

    Full Text Available A gramática da forma constitui uma importante ferramenta que pode dar suporte para futuros estudos e melhor qualidade em conjuntos habitacionais. A utilização de sistemas generativos de projeto pode aperfeiçoar uma série de rotinas de projeto, potencializando seu uso com outras ferramentas de informática. Este trabalho apresenta os resultados de estudo exploratório com um sistema generativo de projeto em processo de simulação e imersão, por meio do qual se pode avaliar o desenvolvimento e as alterações do projeto de implantação de conjunto habitacional social, ocasionadas pela variação das regras nos algoritmos criados. Inicialmente, se realizou a leitura Analítica da Gramática da Forma de um Conjunto Habitacional específico e, posteriormente, simulou-se em ferramenta computacional a Gramática da Forma Paramétrica, para futuros estudos de melhorias em conjuntos habitacionais similares. Tal ferramenta visa desenvolver soluções inovadoras em tecnologia da informação e comunicação aplicadas à construção e arquitetura. Os resultados demonstram a potencialidade do uso da Gramática da Forma, permitindo a inserção de novos parâmetros a cada momento, criando a perspectiva de flexibilidade na concepção e gerando diversas possibilidades que podem ser analisadas e comparadas durante o processo de tomada de decisão do projeto.

  9. Positron emission tomography

    International Nuclear Information System (INIS)

    Yamamoto, Y.L.; Thompson, C.J.; Diksic, M.; Meyer, E.; Feindel, W.H.

    1984-01-01

    One of the most exciting new technologies introduced in the last 10 yr is positron emission tomography (PET). PET provides quantitative, three-dimensional images for the study of specific biochemical and physiological processes in the human body. This approach is analogous to quantitative in-vivo autoradiography but has the added advantage of permitting non-invasive in vivo studies. PET scanning requires a small cyclotron to produce short-lived positron emitting isotopes such as oxygen-15, carbon-11, nitrogen-13 and fluorine-18. Proper radiochemical facilities and advanced computer equipment are also needed. Most important, PET requires a multidisciplinary scientific team of physicists, radiochemists, mathematicians, biochemists and physicians. The most recent trends are reviewed in the imaging technology, radiochemistry, methodology and clinical applications of positron emission tomography. (author)

  10. A Sintaxe da Janela

    Directory of Open Access Journals (Sweden)

    Luís Antônio Jorge

    1993-12-01

    Full Text Available A preocupação fundamenta! do trabalho é de caráter ontológico: esboçar o problema das significações apriorísticas e autônomas dos elementos que compõem a sintaxe arquitetônica. O trabalho elege um desses elementos: a janela. Este artigo parte da aproximação histórica entre a janela e a secção da pirâmide visual, construção imaginária da teoria da perspectiva renascentista. A consideração da janela na linguagem arquitetônica implica reconhecer uma ambigüidade essencial: a janela deve inserir-se ordenadamente no plano da parede - raciocínio típico da modenatura - mas também relacionar-se com a imagem vista através dela, que extrapola o plano, ressaltando a tridimensionalidade - herança da perspectiva renascentista, fundamentada no espaço euclidiano. Ver janela ou ver através da janela são alternativas que se colocam tanto ao observador interno ao edifício, quanto ao externo. Texto de duplaface, a sintaxe da janela versa sobre o relacionamento desses dois lados

  11. LUCRO, VALOR CONTABIL E DIVIDENDOS NA AVALIAcAO DO PATRIMÔNIO LIQUIDO

    Directory of Open Access Journals (Sweden)

    James A. Ohlson

    2009-09-01

    Full Text Available A contabilidade atribui uma importante função integrativa a demonstração das mutações do patrimônio liquido. A demonstração inclui os itens mais importantes do balanço o e da demonstração de resultado do exercício - o valor do patrimônio liquido e o lucro - e sua forma de apresentação exige que a alteração no valor do patrimônio liquido seja igual ao lucro menos os dividendos (líquidos das contribuições para aumento de capital. Referimo-nos a essa relação corno sendo a “relação de lucro limpo", pois, da forma como foi articulada, todas as alterações nos ativos e passivos que não estejam relacionadas com os dividendos devem passar pela demonstração de resultado do exercício. A teoria da contabilidade adota geralmente esse esquema sem relacioná-lo a perspectiva do usuário dos dados contábeis. Contudo, a idéia fundamental de que estoques (líquidos de valor são compatíveis com a criação c distribuição de valor levanta uma questão básica no contexto de avalia4ao do patrimônio liquido: e possível delinear urna teoria coesiva do valor de uma firma sustentada pela relação de lucro limpo, no intuito de se identificar um papel claro para cada uma das três variáveis, quais sejam: o lucro, o valor contábil do patrimônio liquido e os dividendos?

  12. Myocardial blood flow quantification for evaluation of coronary artery disease by positron emission tomography, cardiac magnetic resonance imaging, and computed tomography.

    Science.gov (United States)

    Waller, Alfonso H; Blankstein, Ron; Kwong, Raymond Y; Di Carli, Marcelo F

    2014-05-01

    The noninvasive detection of the presence and functional significance of coronary artery stenosis is important in the diagnosis, risk assessment, and management of patients with known or suspected coronary artery disease. Quantitative assessment of myocardial perfusion can provide an objective and reproducible estimate of myocardial ischemia and risk prediction. Positron emission tomography, cardiac magnetic resonance, and cardiac computed tomography perfusion are modalities capable of measuring myocardial blood flow and coronary flow reserve. In this review, we will discuss the technical aspects of quantitative myocardial perfusion imaging with positron emission tomography, cardiac magnetic resonance imaging, and computed tomography, and its emerging clinical applications.

  13. Computed Tomography Technology: Development and Applications for Defence

    International Nuclear Information System (INIS)

    Baheti, G. L.; Saxena, Nisheet; Tripathi, D. K.; Songara, K. C.; Meghwal, L. R.; Meena, V. L.

    2008-01-01

    Computed Tomography(CT) has revolutionized the field of Non-Destructive Testing and Evaluation (NDT and E). Tomography for industrial applications warrants design and development of customized solutions catering to specific visualization requirements. Present paper highlights Tomography Technology Solutions implemented at Defence Laboratory, Jodhpur (DLJ). Details on the technological developments carried out and their utilization for various Defence applications has been covered.

  14. ANÁLISE EXPERIMENTAL DA INFLUÊNCIA DA TECNOLOGIA HOMEPLUG NA QUALIDADE DA ENERGIA ELÉTRICA

    Directory of Open Access Journals (Sweden)

    Antonio Luiz Pereira de Siqueira Campos

    2008-03-01

    Full Text Available Trabalhos recentes têm estudado características do meio elétrico para a transmissão de dados, ruídos e técnicas empregadas na comunicação pela rede elétrica. A maioria dos trabalhos limita-se a fazer testes de desempenho do protocolo. Diversos pesquisadores têm se preocupado com a influência das transmissões de dados na rede elétrica sobre as comunicações sem fio, mas ninguém tem se preocupado com a influência dessas transmissões na qualidade da energia elétrica. Este trabalho apresenta resultados preliminares sobre o efeito produzido por redes de computadores que utilizam a tecnologia Homeplug 1.0 na qualidade da energia elétrica. Para isso, foram escolhidos parâmetros apropriados para análise da qualidade da energia elétrica, bem como, foram definidas as formas de se obter esses parâmetros. Foi montada uma rede de computadores, com modem’s PLC, no CEFET-RN e realizados testes iniciais para medição da qualidade de energia elétrica. Resultados numéricos são apresentados.

  15. O panorama das Drogas no México: da margem da sociedade ao centro da cultura

    Directory of Open Access Journals (Sweden)

    Diana Palaversich

    2013-12-01

    Full Text Available O artigo destaca o percurso das manifestações culturais ligadas ao tráfico de drogas no México, de um lugar marginal, de subcultura, na sociedade mexicana das décadas de 1970 e 1980, expressas principalmente através dos narcocorridos e do narcocine, para um lugar no mainstream cultural mexicano, desde o início do século 21, com destaque especial para a narcoliteratura. O aumento da violência, provocado pela guerra ao narcotráfico, produz uma proliferação da temática nos meios de comunicação e se reflete em áreas da cultura como as artes plásticas e a literatura, produzindo um novo tipo de expressão artística ou narrativa, que tanto pode ser oportunista e contribuir para a banalização da violência do narcotráfico como ser crítica e narrar o impacto individual e coletivo do tráfico de drogas, narrar a desenfreada e violenta realidade mexicana sem cair no estilo da imprensa marrom, do folclore ou dos lugares comuns dos romances de ação.

  16. Depressão e ansiedade em profissionais da educação das regiões da Amerios e da AMEOSC

    Directory of Open Access Journals (Sweden)

    Roque Strieder

    2010-07-01

    Full Text Available Estudos anteriores evidenciaram a existência de baixa autoestima em profissionais da educação. Esta, aliada ao sentimento de pessimismo, sensação de fracasso, culpa e autodepreciação, torna temeroso o sucesso de ações educacionais. São sentimentos que conduzem a atitudes de indecisão e irritabilidade; podem prejudicar o processo educacional e aprendente. Com o uso de escalas oficiais, da psicologia, propõe-se dimensionar a propensão a sintomas de depressão e ansiedade em professores das regiões da Amerios e da AMEOSC, como forma de contribuir com a tomada de decisões tanto em relação à qualificação quanto de ajuda a ser prestada aos professores. Foram envolvidos na pesquisa, aproximadamente, 20% dos professores da rede estadual e municipal das duas regiões. Eles responderam às questões dos formulários: Inventário de Depressão de Beck (depressão e Escala de Avaliação de Hamilton (ansiedade. Os resultados mostram que os professores pesquisados da rede estadual apresentam tendências a estados depressivos e de ansiedade superiores aos da rede municipal. Conclui-se que, para além da necessária qualificação profissional, os professores necessitam de outras formas de ajuda, como melhor compreensão do ambiente de trabalho, das formas inter-relacionais da atualidade, das formas de fortalecimento da autoestima e confiança, do reconhecimento humano, social e econômico; também, é importante elaborar estratégias de ação que impeçam a perda da autoestima; por último, reconhece-se que os professores precisam de atenção, ajuda e valorização.

  17. EOL3 M0 X-ray Tomography Test Results

    CERN Document Server

    Avramidou, R; Bozhko, N; Borisov, A; Goriatchev, V; Goriatchev, S; Gushin, V; Fakhroutdinov, R; Kojine, A; Kononov, A; Larionov, A; Salomatin, Yu I; Schuh, S; Sedykh, Yu; Tchougouev, A

    2001-01-01

    Results of X-ray tomography test of EOL3 module 0 chamber is presented in the note. Peculiarities of the X-ray tomography of the chamber are discussed. Comparison of the tomography results with predictions of the production site measurements is made.

  18. Positron emission tomography

    International Nuclear Information System (INIS)

    Iio, Masahiro

    1982-01-01

    Utilization of positron emission tomography was reviewed in relation to construction and planned construction of small-size medical cyclotrons, planned construction of positron cameras and utilization of short-lived radionuclides. (Chiba, N.)

  19. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  20. Fresnel: O formulador matemático da teoria ondulatória da luz

    OpenAIRE

    Bassalo, José Maria Filardo

    1988-01-01

    Neste artigo, apresentamos alguns aspectos da vida de Fresnel, engenheiro e físico francês que se notabilizou pela formulação matemática da teoria ondulatória da luz, e cujo bicentenário de nascimento transcorre neste ano de 1988. Realçamos, neste trabalho, suas principais pesquisas relacionadas com o estudo da difração, dupla-refração e reflexão da luz, nas quais utilizou a idéia revolucionária de transversalidade da onda luminosa para deduzir equações, as quais explicaram alg...

  1. A TRANSFORMAÇÃO DA MEMÓRIA EM MERCADORIA: FIM DA PRODUÇÃO FABRIL E A CONTINUIDADE DA “MARCA”

    Directory of Open Access Journals (Sweden)

    Sílvia Aparecida Guarnieri Ortigoza

    2008-04-01

    Full Text Available O resgate da história da Fábrica de Chapéus Sarkis foi retratado neste estudo. Buscou-se analisar as influências da referida fábrica no município de Itapira, principalmente na organização e produção do centro urbano e no cotidiano dos citadinos. Seu fechamento foi entendido a partir das mudanças da moda mundial e de seus reflexos no lugar Itapira – SP, Brasil. Este estudo contempla uma análise regressiva do período (décadas de 1920 a 1960 em que o chapéu era um acessório indispensável na vida cotidiana das pessoas. Reencontrando o presente, procurou-se entender o conteúdo da forma espacial que hoje se encontra em vestígios. O estudo é singular por identificar no espaço geográfico itapirense atual a peculiaridade da transformação da tradição da fábrica em mercadoria.

  2. Positron emission tomography/computed tomography imaging and rheumatoid arthritis.

    Science.gov (United States)

    Wang, Shi-Cun; Xie, Qiang; Lv, Wei-Fu

    2014-03-01

    Rheumatoid arthritis (RA) is a phenotypically heterogeneous, chronic, destructive inflammatory disease of the synovial joints. A number of imaging tools are currently available for evaluation of inflammatory conditions. By targeting the upgraded glucose uptake of infiltrating granulocytes and tissue macrophages, positron emission tomography/computed tomography with fluorine-18 fluorodeoxyglucose ((18) F-FDG PET/CT) is available to delineate inflammation with high sensitivity. Recently, several studies have indicated that FDG uptake in affected joints reflects the disease activity of RA. In addition, usage of FDG PET for the sensitive detection and monitoring of the response to treatment has been reported. Combined FDG PET/CT enables the detailed assessment of disease in large joints throughout the whole body. These unique capabilities of FDG PET/CT imaging are also able to detect RA-complicated diseases. Therefore, PET/CT has become an excellent ancillary tool to assess disease activity and prognosis in RA. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  3. Interstitial pulmonary alterations in visceral leishmaniasis: evaluation with high-resolution computed tomography; Alteracoes pulmonares intersticiais na leishmaniose visceral: avaliacao pela tomografia computadorizada de alta resolucao

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Norma Selma Santos; Cerri, Giovanni Guido [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Dept. de Radiologia

    1999-08-01

    Visceral leishmaniasis, also called kala-azar, is a disease caused by a protozoan, the Leishmania donovani chagasi, that comprises reticuloendothelial system with involvement of the liver, spleen and bone marrow. It is endemic in some areas of northeastern Brazil and other countries of Latin America and Africa. The pathogenesis is related to the immunologic system of patients that present with the inability to activate the phagocytosis of the macrophages. As occurs in the liver and kidneys, the lungs are also involved with interstitial abnormalities caused by Leishmania that are not dependent upon the presence of the parasite. The histopathologic changes described are the involvement of inter alveolar septal in three different phases, irregularly and diffusely throughout the whole pulmonary parenchyma. This work analyzed high-resolution computed tomography (HRCT) of the thorax in 17 patients with visceral leishmaniasis in order to detect and characterize the abnormalities described in the anatomo pathologic findings reported in the literature. The HRCT is being used to evaluate chronic interstitial lung disease in a good correlation with histologic findings. The most common findings detected by HRCT were the reticular opacities that include peribronchovascular interstitial thickening and interlobular septal thickening an ground-glass opacity. The HRCT suggests that similar changes to that found in alveolar structures may occur in the secondary pulmonary lobule and that the involvement in the parenchymal interstitium represents the findings reported by pathological studies in visceral leishmaniasis. (author)

  4. The added value of 18F-fluorodeoxyglucose positron emission tomography computed tomography in patients with neck lymph node metastases from an unknown primary malignancy.

    Science.gov (United States)

    Prowse, S J B; Shaw, R; Ganeshan, D; Prowse, P M; Hanlon, R; Lewis-Jones, H; Wieshmann, H

    2013-08-01

    The search for a primary malignancy in patients with a metastatic cervical lymph node is challenging yet ultimately of utmost clinical importance. This study evaluated the efficacy of positron emission tomography computed tomography in detecting the occult primary, within the context of a tertiary referral centre head and neck cancer multidisciplinary team tumour board meeting. Thirty-two patients (23 men and 9 women; mean and median age, 61 years) with a metastatic cervical lymph node of unknown primary origin, after clinical examination and magnetic resonance imaging, underwent positron emission tomography computed tomography. The primary tumour detection rate was 50 per cent (16/32). Positron emission tomography computed tomography had a sensitivity of 94 per cent (16/17) and a specificity of 67 per cent (10/15). Combining these results with those of 10 earlier studies of similar patients gave an overall detection rate of 37 per cent. Positron emission tomography computed tomography has become an important imaging modality. To date, it has the highest primary tumour detection rate, for head and neck cancer patients presenting with cervical lymph node metastases from an unknown primary.

  5. Decision theory on the quality evaluation of medical images; A teoria da decisao na avaliacao da qualidade da imagem medica

    Energy Technology Data Exchange (ETDEWEB)

    Lessa, Patricia Silva

    2001-10-01

    The problem of quality has been a constant issue in every organization.One is always seeking to produce more, to do it at a lower cost, and to do it with better quality. However, in this country, there is no radiographic film quality control system for radiographic services. The tittle that actually gets done is essentially ad hoc and superficial. The implications of this gap, along with some other shortcomings that exist in process as a whole (the state of the x-ray equipment, the adequate to use in order to obtain a radiography, the quality of the film, the processing of the film, the brightness and homogeneity of the viewing boxes, the ability of the radiologist), have a very negative impact on the quality of the medical image, and, as result, to the quality of the medical diagnosis and therapy. It frequently happens that many radiographs have to be repeated, which leads to an increase of the patient's exposure to radiation, as well as of the cost of the procedure for the patient. Low quality radiographs that are not repeated greatly increase the probability of a wrong diagnosis, and consequently, of inadequate therapeutical procedures, thus producing increased incidence of bad outcomes and higher costs. The paradigm proposed in order to establish a system for the measurement of the image's quality is Decision Theory. The problem of the assessment of the image is studied by proposing a Decision Theory approach. The review of the literature reveals a great concern with the quality of the image, along with an absence of an adequate paradigm and several essentially empirical procedures. Image parameters are developed in order to formalize the problem in terms of Decision Theory, and various aspects of image digitalisation are exposed. Finally, a solution is presented, including a protocol for quality control. (author)

  6. Positron emission tomography/computed tomography and radioimmunotherapy of prostate cancer

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Capala, Jacek; Oehr, Peter

    2009-01-01

    of a number of diagnostic and therapeutic strategies. J591, a monoclonal antibody, which targets the extracellular domain of prostate-specific membrane antigen, shows promising results. HER2 receptors may also have a potential as target for PET/CT imaging and RIT of advanced prostate cancer. SUMMARY: PET......PURPOSE OF REVIEW: Traditional morphologically based imaging modalities are now being complemented by positron emission tomography (PET)/computed tomography (CT) in prostate cancer. Metastatic prostate cancer is an attractive target for radioimmunotherapy (RIT) as no effective therapies...... are available. This review highlights the most important achievements within the last year in PET/CT and RIT of prostate cancer. RECENT FINDINGS: Conflicting results exist on the use of choline for detection of malignant disease in the prostate gland. The role of PET/CT in N-staging remains to be elucidated...

  7. Didáctica da física e didáctica da química : experimentação no ensino da física e da química

    OpenAIRE

    Pereira, Alda

    1991-01-01

    Formação - Professores A componente experimental no ensino da Física e da Química. Experimentação na sala de aula e alguns exemplos. Disciplina “Didáctica da Física e da Química”, do Curso de Profissionalização em Exercício.

  8. Computed tomography of the adrenals in patients with tuberculosis; Emprego da tomografia computadorizada na deteccao de alteracoes das adrenais em doentes com tuberculose

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Seizo; Machado, Jussara Marcondes; Morceli, Jose [UNESP, Botucatu, SP (Brazil). Faculdade de Medicina. Dept. de Doencas Tropicais e Diagnostico por Imagem]. E-mail: seizo_eid@uol.com.br

    2004-06-01

    We evaluated the adrenals of individuals without tuberculosis (group 1 - G1) and with tuberculosis (group 2 - G2) using computed tomography. The antero-posterior length, the thickness, and the longitudinal length of the adrenals were compared in G1 and G2. The duration of the disease, the occurrence of morphologic abnormalities in G2, the distribution according to sex, age and skin color were also studied. There was difference in the antero-posterior length and thickness of right adrenal between G1 and G2. A higher prevalence of white skin male individuals was observed in G2. There was no association between duration of the disease and the occurrence of morphologic abnormalities in G2. A higher occurrence of adrenal enlargement was observed in G2. The main computed tomography findings in patients with tuberculosis were enlargement of the adrenal without calcification, enlargement of the adrenal with punctiform calcifications, and residual calcification of the adrenal. (author)

  9. Computed tomography of intussusception in adult

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Ahn, Byeong Yeob; Cha, Soon Joo; Seol, Hae Young; Chung, Kyoo Byung; Suh, Won Hyuck

    1984-01-01

    Intussusception is rare in adult and usually caused by organic lesions, although there is a significant number of so-called idiopathic cases. The diagnosis of intussusception have been made by plain abdomen, barium enema and small bowel series. But recently ultrasound and computed tomography make a contribution to diagnose intussusception. Computed tomography is not the primary means for evaluating a gastrointestinal tract abnormality but also provides valuable information in evaluating disorders affecting the hollow viscera of the alimentary tract. Computed tomography image of intussusception demonstrates a whirl like pattern of bowel loops separated by fatty stripe correlating of the intestinal walls. Abdominal ultrasonogram was used as the initial diagnostic test in 2 cases out of total 4 cases, with abdominal mass of unknown cause. It revealed a typical pattern, composed of a round or oval mass with central dense echoes and peripheral poor echoes. We report 4 all cases of intussusception in adult who were performed by computed tomography and/or ultrasound. All cases were correlated with barium enema examination and/or surgical reports.

  10. The major histocompatibility complex genes impact pain response in DA and DA.1U rats.

    Science.gov (United States)

    Guo, Yuan; Yao, Fan-Rong; Cao, Dong-Yuan; Li, Li; Wang, Hui-Sheng; Xie, Wen; Zhao, Yan

    2015-08-01

    Our recent studies have shown that the difference in basal pain sensitivity to mechanical and thermal stimulation between Dark-Agouti (DA) rats and a novel congenic DA.1U rats is major histocompatibility complex (MHC) genes dependent. In the present study, we further used DA and DA.1U rats to investigate the role of MHC genes in formalin-induced pain model by behavioral, electrophysiological and immunohistochemical methods. Behavioral results showed biphasic nociceptive behaviors increased significantly following the intraplantar injection of formalin in the hindpaw of DA and DA.1U rats. The main nociceptive behaviors were lifting and licking, especially in DA rats (PDA rats were significantly higher than those in DA.1U rats in both phases of the formalin test (PDA rats was significantly higher than that of DA.1U rats (PDA was greater than that in DA.1U rats (PDA rats was significantly higher than that in DA.1U rats in the respective experimental group (PDA and DA.1U rats exhibited nociceptive responses in formalin-induced pain model and DA rats were more sensitive to noxious chemical stimulus than DA.1U rats, indicating that MHC genes might contribute to the difference in pain sensitivity. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. A Clinical Evaluation Of Cone Beam Computed Tomography

    Science.gov (United States)

    2016-06-01

    A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY by Bryan James Behm, D.D.S. Lieutenant, Dental Corps United States Navy A thesis... COMPUTED TOMOGRAPHY " is appropriately acknowledged and, beyond brief excerpts, is with the permission of the copyright owner. ~mes Behm Endodontic...printed without the expressed written permission of the author. IV ABSTRACT A CLINICAL EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY BRYAN JAMES

  12. Computed tomography of tibial plateau fractures

    International Nuclear Information System (INIS)

    Rafii, M.; Firooznia, H.; Golimbu, C.; Bonamo, J.

    1984-01-01

    Twenty patients with tibial plateau fractures were studied by conventional tomography and computed tomography (CT) in order to determine the role and feasibility of CT in management of such patients. CT resulted in less discomfort to the patient and provided optimal visualization of the plateau defect and the split fragments. It proved more accurate than conventional tomography in assessing depressed and split fractures when they involved the anterior or posterior border of the plateau and in demonstrating the extent of fracture comminution. Split fragments with an oblique plane of fracture also were seen better by CT. The degree of fracture depression and separation as measured by the computerized technique was often more accurate than measurements obtained from conventional tomograms

  13. BIOTECNOLOGIA, DESENVOLVIMENTO E INOVAÇÃO: REFLEXÕES ACERCA DA PROPRIEDADE INTELECTUAL, LEI DE CULTIVARES E DA LICENÇA COMPULSÓRIA NO ÂMBITO DA BIOTECNOLOGIA

    Directory of Open Access Journals (Sweden)

    Fabiane Oliveira

    2014-12-01

    Full Text Available Considera-se o contexto dos processos de inovação e desenvolvimento no mundo moderno, a preocupação socioambiental e a tecnologia desenvolvida em função da agroindústria. Destaca-se a crescente importância conferida à biotecnologia na sociedade contemporânea. Reflete-se criticamente o estudo da propriedade intelectual no âmbito da biotecnologia em face do Estado e da inovação e do desenvolvimento. Busca-se, primeiramente, apresentar definição, origem e aspecto relevante da biotecnologia, a fim de tornar a sapiência desta ciência mais pragmática. Posto isso, elucida-se sobre a área de abrangência da proteção da propriedade intelectual nesse ramo da ciência. Nesse viés, ocupa-se também de demonstrar a Lei de Propriedade Intelectual mediante a problemática das patentes no setor biotecnológico. Observa-se, a seguir, o estudo da Lei de Cultivares em função da utilização do mecanismo de prospecção de patentes. Demonstra-se os aspectos importantes e o impacto da Lei de Cultivares no âmbito da propriedade intelectual. Exemplifica-se as cultivares protegidas. Apresenta-se a problemática da licença compulsória no âmbito da propriedade intelectual no ramo da biotecnologia. Objetiva-se demonstrar a situação desse ramo da ciência sob o prisma da propriedade intelectual, do fortalecimento e da padronização desses direitos. Expõe-se, por último, a importância da proteção dessa ciência para o desenvolvimento e para a inovação no país. Para isso, recorta-se a analise atual da Biotecnologia e da Propriedade Intelectual no Brasil sob o enfoque da legislação especifica e da hipótese da licença compulsória. Utiliza-se de pesquisa bibliográfica na área de biotecnologia, economia e direito, sob o enfoque da propriedade intelectual, inovação e do desenvolvimento.

  14. Are the imaging findings used to assess the portal triad reliable to perform living-donor liver transplant?; Os achados de imagem para avaliacao da triade portal sao confiaveis para realizacao do transplante hepatico com doador vivo?

    Energy Technology Data Exchange (ETDEWEB)

    Dazzi, Francisco Leoncio; Ribeiro Junior, Marcelo Augusto Fontenelle; Mancero, Jorge Marcelo Padilla; Gonzalez, Adriano Miziara; D' Albuquerque, Luiz Augusto Carneiro, E-mail: franciscodazzi@hotmail.com [Hospital Beneficencia Portuguesa, Sao Paulo, SP (Brazil). Departamento de Cirurgia Geral e Transplante; Leao-Filho, Hilton Muniz [Hospital Beneficencia Portuguesa, Sao Paulo, SP (Brazil). Departamento de Radiologia e Diagnostico por Imagem; Silva, Adavio de Oliveira e [Hospital Beneficencia Portuguesa, Sao Paulo, SP (Brazil). Departamento de Gastroenterologia e Hepatologia

    2013-07-01

    Background: a crucial aspect of living-donor liver transplant is the risk imposed to the donor due to a procedure performed in a healthy individual that can lead to a high postoperative morbidity rate Aim: To correlate the pre- and intraoperative hepatic imaging findings of living adult donors. Methods: From 2003 to 2008 the medical charts of 66 donors were revised; in that, 42 were males (64%) and 24 females (36%), mean age of 30±8 years. The preoperative anatomy was analyzed by magnetic resonance cholangiography to study the bile ducts and by computed tomography angiography to evaluate the hepatic artery and portal vein. Normalcy criteria were established according to previously published studies. Results: Anatomic variations of the bile ducts were found in 59.1% of donors, of the artery hepatic in 31.8% and of the portal vein in 30.3% of the cases during the preoperative period. The magnetic resonance cholangiography findings were in agreement in 44 (66.6%) of donors and in disagreement in 22 (33.3%). With regards to hepatic artery, in all donors the findings of the imaging examination were in agreement with those of the intraoperative period. As to the portal vein, the computed tomography findings were in agreement in 59 (89.4%) donors and in disagreement in seven (10.6%). Conclusions: the bile duct anatomic variations are frequent, and the magnetic resonance cholangiography showed moderate accuracy (70%) in reproducing the surgical findings; the computed tomography reproduced the intraoperative findings of the hepatic artery in 100% of donors, and of the portal vein in 89.4% of the cases, thus demonstrating high accuracy (89%). (author)

  15. Evaluation of computed tomography for obstructive jaundice

    International Nuclear Information System (INIS)

    Matsuoka, Shoji; Toda, Hiroshi; Suzuki, Toshihiko

    1980-01-01

    Findings of computed tomography were reviewed in 54 cases where obstructive jaundice was suggested by liver function studies and computed tomography was done with the diagnosis subsequently confirmed by surgery. Dilatation of the intrahepatic bile duct was found in 49 (91%) of the cases and the site of obstruction was determined in 44 cases (82%). The cause was shown in 28 cases (52%). By disease, the cause was correctly diagnosed with gallbladder in 40%, bile duct cancer in 46%, pancreas cancer in 71%, and choledocal cyst in 100%, but cholelithiasis was diagnosed correctly in only 17%. Further, non-calcium cholelithiasis is very difficult to diagnose by computed tomography. Computed tomography is a useful tool for diagnosis of obstructive jaundice as a noninvasive means of evaluating the patient; however, concomitand use of other diagnostic studies is essential for greater accuracy of diagnosis. (author)

  16. O CAMINHAR DA CIÊNCIA DA INFORMAÇÃO E O XV ENCONTRO NACIONAL DE PESQUISA EM CIÊNCIA DA INFORMAÇÃO

    Directory of Open Access Journals (Sweden)

    Renata Maria Abrantes Baracho

    2014-10-01

    Full Text Available Este artigo descreve algumas características da Ciência da Informação como área do conhecimento e apresenta o Encontro Nacional de Pesquisa em Ciência da Informação (ENANCIB como o evento seminal da área. Busca-se criar a memória do ENANCIB, promovido pela Associação Nacional de Pesquisa e Pós-Graduação em Ciência da Informação (ANCIB, desde a sua criação em 1994, ao longo de suas quinze edições. O ENANCIB congrega pesquisadores e programas de pós-graduação nacionais, além de propiciar um fórum para discussão dos temas de pesquisa da área. Em 2014, o XV ENANCIB tem lugar em Belo Horizonte – Minas Gerais e é organizado pelo Programa de Pós-Graduação em Ciência da Informação (PPGCI da Escola de Ciência da Informação (ECI da Universidade Federal de Minas Gerais de Minas Gerais (UFMG. No âmbito do PPGCI, nasceu a percepção de que o evento deveria propor a discussão sobre como as mais recentes tecnologias da informação e da comunicação têm alterado a sociedade e a forma de interagir das pessoas, bem como o papel relevante da Ciência da Informação nesse contexto. Os dispositivos móveis, nuvens, big data, linked data, dentre outras formas de interagir com a informação têm causado transformações em vários âmbitos e exigido novas abordagens para os estudos em CI. O tema do XV ENANCIB “Além das `nuvens´: expandindo as fronteiras da Ciência da Informação”, proporciona a oportunidade para refletir sobre essas mudanças que impactam na interação humana com a informação, bem como sobre suas implicações para o futuro da CI.

  17. [Leonardo da Vinci the first human body imaging specialist. A brief communication on the thorax oseum images].

    Science.gov (United States)

    Cicero, Raúl; Criales, José Luis; Cardoso, Manuel

    2009-01-01

    The impressive development of computed tomography (CT) techniques such as the three dimensional helical CT produces a spatial image of the thoracic skull. At the beginning of the 16th century Leonardo da Vinci drew with great precision the thorax oseum. These drawings show an outstanding similarity with the images obtained by three dimensional helical CT. The cumbersome task of the Renaissance genius is a prime example of the careful study of human anatomy. Modern imaging techniques require perfect anatomic knowledge of the human body in order to generate exact interpretations of images. Leonardo's example is alive for anybody devoted to modern imaging studies.

  18. ESTUDO DA ALTERAÇÃO DA COR E DEGRADAÇÃO DA CLOROFILA DURANTE ARMAZENAGEM DE ERVA-MATE TIPO CHIMARRÃO

    OpenAIRE

    Gisela Cabral Malheiros

    2007-01-01

    A Ilex paraguariensis A. St.-Hill., conhecida popularmente como erva-mate, é uma espécie nativa da região subtropical da América do Sul, a qual é matéria-prima para o produto ervamate, utilizado principalmente no preparo da bebida chimarrão. Dentre os atributos sensoriais da erva-mate tipo chimarrão, a cor constitui o primeiro critério utilizado pelo consumidor para sua aceitabilidade. A cor verde da erva-mate deve-se à presença de clorofila. Ocorrem perdas expressivas de clorofila no proc...

  19. Neutron and X-ray Tomography (NeXT) system for simultaneous, dual modality tomography

    Science.gov (United States)

    LaManna, J. M.; Hussey, D. S.; Baltic, E.; Jacobson, D. L.

    2017-11-01

    Dual mode tomography using neutrons and X-rays offers the potential of improved estimation of the composition of a sample from the complementary interaction of the two probes with the sample. We have developed a simultaneous neutron and 90 keV X-ray tomography system that is well suited to the study of porous media systems such as fuel cells, concrete, unconventional reservoir geologies, limestones, and other geological media. We present the characteristic performance of both the neutron and X-ray modalities. We illustrate the use of the simultaneous acquisition through improved phase identification in a concrete core.

  20. Tomography with energy dispersive diffraction

    Science.gov (United States)

    Stock, S. R.; Okasinski, J. S.; Woods, R.; Baldwin, J.; Madden, T.; Quaranta, O.; Rumaiz, A.; Kuczewski, T.; Mead, J.; Krings, T.; Siddons, P.; Miceli, A.; Almer, J. D.

    2017-09-01

    X-ray diffraction can be used as the signal for tomographic reconstruction and provides a cross-sectional map of the crystallographic phases and related quantities. Diffraction tomography has been developed over the last decade using monochromatic x-radiation and an area detector. This paper reports tomographic reconstruction with polychromatic radiation and an energy sensitive detector array. The energy dispersive diffraction (EDD) geometry, the instrumentation and the reconstruction process are described and related to the expected resolution. Results of EDD tomography are presented for two samples containing hydroxyapatite (hAp). The first is a 3D-printed sample with an elliptical crosssection and contains synthetic hAp. The second is a human second metacarpal bone from the Roman-era cemetery at Ancaster, UK and contains bio-hAp which may have been altered by diagenesis. Reconstructions with different diffraction peaks are compared. Prospects for future EDD tomography are also discussed.

  1. Recent advances in neutron tomography

    International Nuclear Information System (INIS)

    McFarland, E.; Massachusetts Inst. of Technology, Cambridge, MA; Lanza, R.

    1993-01-01

    Neutron imaging has been shown to be an excellent imaging tool for many nondestructive evaluation applications. Significantly improved contrast over X-ray images is possible for materials commonly found in engineering assemblies. The major limitations have been the neutron source and detection. A low cost, position sensitive neutron tomography detector system has been designed and built based on an electro-optical detector system using a LiF-ZnS scintillator screen and a cooled charge coupled device. This detector system can be used for neutron radiography as well as two and three-dimensional neutron tomography. Calculated performance of the system predicted near-quantum efficiency for position sensitive neutron detection. Experimental data was recently taken using this system at McClellan Air Force Base, Air Logistics Center, Sacramento, CA. With increased availability of low cost neutron sources and advanced image processing, neutron tomography will become an increasingly important nondestructive imaging method

  2. Computed tomography in the diagnosis of pericardial heart disease

    International Nuclear Information System (INIS)

    Isner, J.M.; Carter, B.L.; Bankoff, M.S.; Konstam, M.A.; Salem, D.N.

    1982-01-01

    To evaluate the use of computed tomography (CT) in the diagnosis of pericardial heart disease, 53 patients were prospectively studied by computed tomography of the chest and cardiac ultrasound. A diagnostic-quality CT study was done for all patients; a technically satisfactory ultrasound examination was not possible in six patients. Of 47 patients in whom both chest scans and satisfactory ultrasound studies were obtained, computed tomography showed pericardial thickening not shown by ultrasound in five patients. Estimated size of pericardial effusion was the same for both computed tomography and ultrasound. Computed tomography provided quantifiable evaluation of the composition of pericardial fluid in seven patients with either hemopericardium or purulent pericarditis. Neoplastic pericardial heart disease was detected by CT scan in four of the 53 patients. Computed tomography of the chest provides a sensitive evaluation of the pericardium and quality of pericardial effusion, and is a valuable adjunct in patients in whom cardiac ultrasound is technically unsatisfactory

  3. Clinical utility of dental cone-beam computed tomography: current perspectives

    Directory of Open Access Journals (Sweden)

    Jaju PP

    2014-04-01

    Full Text Available Prashant P Jaju,1 Sushma P Jaju21Oral Medicine and Radiology, 2Conservative Dentistry and Endodontics, Rishiraj College of Dental Sciences and Research Center, Bhopal, IndiaAbstract: Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology and forensic dentistry, and its limitations in maxillofacial diagnosis.Keywords: dental implants, cone-beam computed tomography, panoramic radiography, computed tomography

  4. Diagnostic imaging of dementia with Lewy bodies by susceptibility-weighted imaging of nigrosomes versus striatal dopamine transporter single-photon emission computed tomography: a retrospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kamagata, Koji; Sato, Kanako; Suzuki, Michimasa; Hori, Masaaki; Kumamaru, Kanako K.; Aoki, Shigeki [Juntendo University Graduate School of Medicine, Department of Radiology, Bunkyo-ku, Tokyo (Japan); Nakatsuka, Tomoya; Inaoka, Tsutomu; Terada, Hitoshi [Toho University Sakura Medical Center, Department of Radiology, Sakura, Sakura (Japan); Sakakibara, Ryuji; Tsuyusaki, Yohei [Toho University Sakura Medical Center, Department of Neurology, Sakura, Sakura (Japan); Takamura, Tomohiro [University of Yamanashi, Department of Radiology, Chuo-shi, Yamanashi (Japan)

    2017-01-15

    The characteristics of dementia with Lewy bodies (DLB), Alzheimer's disease (AD) and amnestic mild cognitive impairment (a-MCI) overlap but require different treatments; therefore, it is important to differentiate these pathologies. Assessment of dopamine uptake in the striatum using dopamine transporter (DaT) single-photon emission computed tomography (SPECT) is the gold standard for diagnosing DLB; however, this modality is expensive, time consuming and involves radiation exposure. Degeneration of the substantia nigra nigrosome-1, which occurs in DLB, but not in AD/a-MCI, can be identified by 3T susceptibility-weighted imaging (SWI). Therefore, the aim of this retrospective observational study was to compare SWI with DaT-SPECT for differentiation of DLB from AD/a-MCI. SWI data were acquired for patients with clinically diagnosed DLB (n = 29), AD (n = 18), a-MCI (n = 13) and healthy controls (n = 26). Images were analysed for nigrosome-1 degeneration. Diagnostic accuracy was evaluated for DLB, AD and a-MCI compared with striatal dopamine uptake using DaT-SPECT. SWI achieved 90% diagnostic accuracy (93% sensitivity, 87% specificity) for the detection of nigrosome-1 degeneration in DLB and not in AD/a-MCI as compared with 88.3% accuracy (93% sensitivity, 84% specificity) using DaT-SPECT. SWI nigrosome-1 evaluation was useful in differentiating DLB from AD/a-MCI, with high accuracy. This less invasive and less expensive method is a potential alternative to DaT-SPECT for the diagnosis of DLB. (orig.)

  5. Report of two cases of fluorodeoxyglucose positron emission tomography/computed tomography appearance of hibernoma: A rare benign tumor

    International Nuclear Information System (INIS)

    Agrawal, Archi; Kembhavi, Seema; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2014-01-01

    False-positive findings are commonly seen in positron emission tomography computed tomography imaging. One of the most common false positive finding is uptake of fluorodeoxyglucose in brown adipose tissue. Herein, we report two cases with incidentally detected hibernomas-a brown fat containing tumor with metabolic activity

  6. Positron Emission Tomography/Computed Tomography-Guided Intensity-Modulated Radiotherapy for Limited-Stage Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Shirvani, Shervin M.; Komaki, Ritsuko; Heymach, John V.; Fossella, Frank V.; Chang, Joe Y.

    2012-01-01

    Purpose: Omitting elective nodal irradiation from planning target volumes does not compromise outcomes in patients with non–small-cell lung cancer, but whether the same is true for those with limited-stage small-cell lung cancer (LS-SCLC) is unknown. Therefore, in the present study, we sought to determine the clinical outcomes and the frequency of elective nodal failure in patients with LS-SCLC staged using positron emission tomography/computed tomography and treated with involved-field intensity-modulated radiotherapy. Methods and Materials: Between 2005 and 2008, 60 patients with LS-SCLC at our institution underwent disease staging using positron emission tomography/computed tomography before treatment using an intensity-modulated radiotherapy plan in which elective nodal irradiation was intentionally omitted from the planning target volume (mode and median dose, 45 Gy in 30 fractions; range, 40.5 Gy in 27 fractions to 63.8 Gy in 35 fractions). In most cases, concurrent platinum-based chemotherapy was administered. We retrospectively reviewed the clinical outcomes to determine the overall survival, relapse-free survival, and failure patterns. Elective nodal failure was defined as recurrence in initially uninvolved hilar, mediastinal, or supraclavicular nodes. Survival was assessed using the Kaplan-Meier method. Results: The median age of the study patients at diagnosis was 63 years (range, 39–86). The median follow-up duration was 21 months (range, 4–58) in all patients and 26 months (range, 4–58) in the survivors. The 2-year actuarial overall survival and relapse-free survival rate were 58% and 43%, respectively. Of the 30 patients with recurrence, 23 had metastatic disease and 7 had locoregional failure. We observed only one isolated elective nodal failure. Conclusions: To our knowledge, this is the first study to examine the outcomes in patients with LS-SCLC staged with positron emission tomography/computed tomography and treated with definitive

  7. Positron Emission Tomography/Computed Tomography-Guided Intensity-Modulated Radiotherapy for Limited-Stage Small-Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Shirvani, Shervin M.; Komaki, Ritsuko [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Heymach, John V.; Fossella, Frank V. [Department of Thoracic/Head and Neck Medical Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Chang, Joe Y., E-mail: jychang@mdanderson.org [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States)

    2012-01-01

    Purpose: Omitting elective nodal irradiation from planning target volumes does not compromise outcomes in patients with non-small-cell lung cancer, but whether the same is true for those with limited-stage small-cell lung cancer (LS-SCLC) is unknown. Therefore, in the present study, we sought to determine the clinical outcomes and the frequency of elective nodal failure in patients with LS-SCLC staged using positron emission tomography/computed tomography and treated with involved-field intensity-modulated radiotherapy. Methods and Materials: Between 2005 and 2008, 60 patients with LS-SCLC at our institution underwent disease staging using positron emission tomography/computed tomography before treatment using an intensity-modulated radiotherapy plan in which elective nodal irradiation was intentionally omitted from the planning target volume (mode and median dose, 45 Gy in 30 fractions; range, 40.5 Gy in 27 fractions to 63.8 Gy in 35 fractions). In most cases, concurrent platinum-based chemotherapy was administered. We retrospectively reviewed the clinical outcomes to determine the overall survival, relapse-free survival, and failure patterns. Elective nodal failure was defined as recurrence in initially uninvolved hilar, mediastinal, or supraclavicular nodes. Survival was assessed using the Kaplan-Meier method. Results: The median age of the study patients at diagnosis was 63 years (range, 39-86). The median follow-up duration was 21 months (range, 4-58) in all patients and 26 months (range, 4-58) in the survivors. The 2-year actuarial overall survival and relapse-free survival rate were 58% and 43%, respectively. Of the 30 patients with recurrence, 23 had metastatic disease and 7 had locoregional failure. We observed only one isolated elective nodal failure. Conclusions: To our knowledge, this is the first study to examine the outcomes in patients with LS-SCLC staged with positron emission tomography/computed tomography and treated with definitive intensity

  8. imaging volcanos with gravity and muon tomography measurements

    Science.gov (United States)

    Jourde, Kevin; Gibert, Dominique; Marteau, Jacques; Deroussi, Sébastien; Dufour, Fabrice; de Bremond d'Ars, Jean; Ianigro, Jean-Christophe; Gardien, Serge; Girerd, Claude

    2015-04-01

    Both muon tomography and gravimetry are geohysical methods that provide information on the density structure of the Earth's subsurface. Muon tomography measures the natural flux of cosmic muons and its attenuation produced by the screening effect of the rock mass to image. Gravimetry generally consists in measurements of the vertical component of the local gravity field. Both methods are linearly linked to density, but their spatial sensitivity is very different. Muon tomography essentially works like medical X-ray scan and integrates density information along elongated narrow conical volumes while gravimetry measurements are linked to density by a 3-dimensional integral encompassing the whole studied domain. We show that gravity data are almost useless to constrain the density structure in regions sampled by more than two muon tomography acquisitions. Interestingly the resolution in deeper regions not sampled by muon tomography is significantly improved by joining the two techniques. Examples taken from field experiments performed on La Soufrière of Guadeloupe volcano are discussed.

  9. Prediction of optimal deployment projection for transcatheter aortic valve replacement: angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography.

    Science.gov (United States)

    Binder, Ronald K; Leipsic, Jonathon; Wood, David; Moore, Teri; Toggweiler, Stefan; Willson, Alex; Gurvitch, Ronen; Freeman, Melanie; Webb, John G

    2012-04-01

    Identifying the optimal fluoroscopic projection of the aortic valve is important for successful transcatheter aortic valve replacement (TAVR). Various imaging modalities, including multidetector computed tomography (MDCT), have been proposed for prediction of the optimal deployment projection. We evaluated a method that provides 3-dimensional angiographic reconstructions (3DA) of the aortic root for prediction of the optimal deployment angle and compared it with MDCT. Forty patients undergoing transfemoral TAVR at St Paul's Hospital, Vancouver, Canada, were evaluated. All underwent preimplant 3DA and 68% underwent preimplant MDCT. Three-dimensional angiographic reconstructions were generated from images of a C-arm rotational aortic root angiogram during breath-hold, rapid ventricular pacing, and injection of 32 mL contrast medium at 8 mL/s. Two independent operators prospectively predicted perpendicular valve projections. The implant angle was chosen at the discretion of the physician performing TAVR. The angles from 3DA, from MDCT, the implant angle, and the postdeployment perpendicular prosthesis view were compared. The shortest distance from the postdeployment perpendicular prosthesis projection to the regression line of predicted perpendicular projections was calculated. All but 1 patient had adequate image quality for reproducible angle predictions. There was a significant correlation between 3DA and MDCT for prediction of perpendicular valve projections (r=0.682, Pregression line of predicted angles to the postdeployment prosthesis view was 5.1±4.6° for 3DA and 7.9±4.9° for MDCT (P=0.01). Three-dimensional angiographic reconstructions and MDCT are safe, practical, and accurate imaging modalities for identifying the optimal perpendicular valve deployment projection during TAVR.

  10. ARTIMANHAS DA HEGEMONIA: OBSTÁCULOS À RADICALIZAÇÃO DA DEMOCRACIA NO BRASIL

    Directory of Open Access Journals (Sweden)

    Frederico Alves Costa

    Full Text Available Resumo Este artigo apresenta como foco o debate sobre dificuldades na construção da luta política na contemporaneidade brasileira, mais especificamente nos últimos anos do governo do Presidente da República Luiz Inácio Lula da Silva. Objetiva-se, a partir do diálogo entre a Teoria Democrática Radical e Plural - desenvolvida por Ernesto Laclau e Chantal Mouffe - e posicionamentos de representantes de diferentes grupos de movimentos sociais brasileiros, discutir dois modos de resistência da hegemonia a alternativas de democratização da sociedade. Esses modos, concebidos como artimanhas da hegemonia, são denominados expansão hegemônica e expurgo à diferença. O debate contribui para a análise sobre estratégias políticas no campo da psicologia social.

  11. The role of computed tomography in the laryngeal injury

    International Nuclear Information System (INIS)

    Bae, Hoon Sik

    1984-01-01

    Computed tomography of the larynx represents a major advance in laryngology. Even in severe injury the larynx can be examined easily and conveniently by CT at the same time as the brain and facial structures without moving the patient, who need only lie down and breathe quietly during the study. Computed tomography permitted a much more detailed appraisal of laryngeal dysfunction in patients with blunt laryngeal trauma (3 cases) and strangulation injury (2 cases). Computed tomography of the larynx undoubtedly played a determinant role in patient management. Computed tomography was helpful in evaluating the laryngeal cartilages and deep spaces of the larynx which was difficult to examine by the laryngoscope. Follow-up computed tomography made it possible to evaluate the postoperative results

  12. Responsabilidade Social das empresas: a contraface da sociedade civil e da cidadania

    Directory of Open Access Journals (Sweden)

    Simionatto, Ivete

    2006-01-01

    Full Text Available O artigo tem como objeto o estudo das mudanças que vêm ocorrendo nas relações entre Estado e sociedade civil e sua manifestação específica nas propostas articuladas em torno da responsabilidade social das empresas. Parte-se da hipótese de que estas práticas vêm contribuindo para a formação de consensos que fortalecem a hegemonia do capital na atualidade, mediante a redução do papel do Estado e o fortalecimento da esfera privada como setor de regulação social. Este cenário indica mudanças nas relações entre Estado e sociedade civil, uma vez que a responsabilidade social das empresas manifesta-se como uma nova proposta de sociabilidade e de resposta às expressões da questão social. Por fim, identifica-se que os serviços sociais oferecidos através da responsabilidade social fortalecem o campo do voluntariado, da solidariedade e das instituições do terceiro setor, precarizam o trabalho do Assistente Social com rebatimentos na esfera da cidadania e dos demais valores e princípios que sustentam o projeto ético-político da profissão

  13. An extension of PPLS-DA for classification and comparison to ordinary PLS-DA.

    Directory of Open Access Journals (Sweden)

    Anna Telaar

    Full Text Available Classification studies are widely applied, e.g. in biomedical research to classify objects/patients into predefined groups. The goal is to find a classification function/rule which assigns each object/patient to a unique group with the greatest possible accuracy (classification error. Especially in gene expression experiments often a lot of variables (genes are measured for only few objects/patients. A suitable approach is the well-known method PLS-DA, which searches for a transformation to a lower dimensional space. Resulting new components are linear combinations of the original variables. An advancement of PLS-DA leads to PPLS-DA, introducing a so called 'power parameter', which is maximized towards the correlation between the components and the group-membership. We introduce an extension of PPLS-DA for optimizing this power parameter towards the final aim, namely towards a minimal classification error. We compare this new extension with the original PPLS-DA and also with the ordinary PLS-DA using simulated and experimental datasets. For the investigated data sets with weak linear dependency between features/variables, no improvement is shown for PPLS-DA and for the extensions compared to PLS-DA. A very weak linear dependency, a low proportion of differentially expressed genes for simulated data, does not lead to an improvement of PPLS-DA over PLS-DA, but our extension shows a lower prediction error. On the contrary, for the data set with strong between-feature collinearity and a low proportion of differentially expressed genes and a large total number of genes, the prediction error of PPLS-DA and the extensions is clearly lower than for PLS-DA. Moreover we compare these prediction results with results of support vector machines with linear kernel and linear discriminant analysis.

  14. Diagnosis of sinusoidal obstruction syndrome by positron emission tomography/computed tomography: report of two cases treated by defibrotide.

    Science.gov (United States)

    Gauthé, Mathieu; Bozec, Laurence; Bedossa, Pierre

    2014-11-01

    Sinusoidal obstruction syndrome (SOS) is a potentially fatal liver injury that mainly occurs after myeloablative chemotherapy. We report two cases of SOS investigated by 18F-fluorodeoxyglucose positron emission tomography/computed tomography and treated with defibrotide. © 2014 by the American Association for the Study of Liver Diseases.

  15. Constraints on mantle convection from seismic tomography

    NARCIS (Netherlands)

    Kárason, H.; Hilst, R.D. van der

    2000-01-01

    Since the advent of global seismic tomography some 25 years ago, advances in technology, seismological theory, and data acquisition have allowed spectacular progress in our ability to image seismic heterogeneity in Earth's mantle. We briefly review some concepts of seismic tomography, such as

  16. 21 CFR 892.1750 - Computed tomography x-ray system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Computed tomography x-ray system. 892.1750 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1750 Computed tomography x-ray system. (a) Identification. A computed tomography x-ray system is a diagnostic x-ray system intended to...

  17. O clássico e o emergente: desafios da produção, da divulgação e da utilização do conhecimento da Enfermagem

    Directory of Open Access Journals (Sweden)

    Márcia de Assunção Ferreira

    2013-09-01

    Full Text Available Reflexão sobre os paradigmas da ciência e os desafios contemporâneos da produção, divulgação e utilização do conhecimento. Abordam-se os desafios relativos à pesquisa do cuidado de enfermagem, os recursos e as estratégias políticas da área para superá-los. Os argumentos se amparam na Enfermagem como disciplina prática e na tríade ensinar-cuidar-pesquisar voltada às demandas dos usuários, com vistas à promoção da saúde e bem-estar, dentro de um paradigma de cuidado. Articular os modelos de ciência, ampliar os recursos humanos, materiais e financeiros, investir nos mestrados profissionais, na ampliação dos programas de pós-graduação acadêmicos e na formação de redes de cooperação são alguns dos desafios e estratégias apontados para que a área enfrente as lutas do campo hegemônico da saúde, da ciência e da tecnologia para se manter no sistema.

  18. Dimensão da maturidade à luz da logoterapia

    Directory of Open Access Journals (Sweden)

    Libardi, Tadeu Antonio

    2008-01-01

    Full Text Available O artigo aborda o tema da maturidade humana à luz da logoterapia, fundada por Viktor Emil Frankl. Nos dias de hoje, existe a frustração existencial, não mais a sexual, como analisada por Freud. Cada ser humano, como pessoa livre e responsável e tendo como meta a busca da maturidade, vai percorrendo seu próprio caminho, que o leva à ceitação de si, de seus limites e potencialidades e ao relacionamento social e religioso, capacitando-o ao confronto com o sofrimento humano

  19. Breast ultrasound tomography with total-variation regularization

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Li, Cuiping [KARMANOS CANCER INSTIT.; Duric, Neb [KARMANOS CANCER INSTIT

    2009-01-01

    Breast ultrasound tomography is a rapidly developing imaging modality that has the potential to impact breast cancer screening and diagnosis. A new ultrasound breast imaging device (CURE) with a ring array of transducers has been designed and built at Karmanos Cancer Institute, which acquires both reflection and transmission ultrasound signals. To extract the sound-speed information from the breast data acquired by CURE, we have developed an iterative sound-speed image reconstruction algorithm for breast ultrasound transmission tomography based on total-variation (TV) minimization. We investigate applicability of the TV tomography algorithm using in vivo ultrasound breast data from 61 patients, and compare the results with those obtained using the Tikhonov regularization method. We demonstrate that, compared to the Tikhonov regularization scheme, the TV regularization method significantly improves image quality, resulting in sound-speed tomography images with sharp (preserved) edges of abnormalities and few artifacts.

  20. A metodologia de projecto na aprendizagem da biodiversidade e geodiversidade na praia da concha

    OpenAIRE

    Rosa, Marina Maria Filipe

    2012-01-01

    Dissertação de mestrado em Biologia e de Geologia, apresentada ao Departamento de Ciências da Terra e ao Departamento de Ciências da Vida Este trabalho consistiu na implementação e avaliação da metodologia de projeto no estudo da Biodiversidade e Geodiversidade na Praia da Concha, Portugal Central, dando ênfase ao trabalho prático, através de uma aula de campo e de aulas laboratoriais. O trabalho foi realizado numa escola da Marinha Grande, com 11 alunos do 10º ano de escolaridade. Sendo a...

  1. Cone beam tomography of the heart using single-photon emission-computed tomography

    International Nuclear Information System (INIS)

    Gullberg, G.T.; Christian, P.E.; Zeng, G.L.; Datz, F.L.; Morgan, H.T.

    1991-01-01

    The authors evaluated cone beam single-photon emission-computed tomography (SPECT) of the heart. A new cone beam reconstruction algorithm was used to reconstruct data collected from short scan acquisitions (of slightly more than 180 degrees) of a detector anteriorally traversing a noncircular orbit. The less than 360 degrees acquisition was used to minimize the attenuation artifacts that result from reconstructing posterior projections of 201T1 emissions from the heart. The algorithm includes a new method for reconstructing truncated projections of background tissue activity that eliminates reconstruction ring artifacts. Phantom and patient results are presented which compare a high-resolution cone beam collimator (50-cm focal length; 6.0-mm full width at half maximum [FWHM] at 10 cm) to a low-energy general purpose (LEGP) parallel hole collimator (8.2-mm FWHM at 10 cm) which is 1.33 times more sensitive. The cone beam tomographic results are free of reconstruction artifacts and show improved spatial and contrast resolution over that obtained with the LEGP parallel hole collimator. The limited angular sampling restrictions and truncation problems associated with cone beam tomography do not deter from obtaining diagnostic information. However, even though these preliminary results are encouraging, a thorough clinical study is still needed to investigate the specificity and sensitivity of cone beam tomography

  2. Influência da idade da planta e da maturação dos frutos no momento da colheita na qualidade do café

    Directory of Open Access Journals (Sweden)

    Borges Fernanda Barbosa

    2002-01-01

    Full Text Available São de grande importância os cuidados no preparo do café desde a colheita até o consumo e o estudo de parâmetros que possam influenciar na classificação comercial do grão e na qualidade da bebida. Teve-se como objetivos analisar a influência da idade das plantas, pertencentes à mesma variedade, e dos estágios de maturação dos grãos (secos, cerejas e verdes no resultado da classificação comercial e na qualidade da bebida. Realizou-se a colheita, por derriça no pano, de uma área com café arábica variedade Catuaí de 12 anos e de outra de 3 anos. Constituiu-se, para cada idade das plantas, os seguintes lotes: 100% cereja, 60% cereja e 40% verde, 80% cereja e 20% verde, 60% cereja e 40% seco, 80% cereja e 20% seco, e composição obtida na colheita. Na classificação comercial, obedeceu-se as normas estabelecidas pela Tabela Oficial Brasileira de Classificação (tipo, peneira, aspecto, cor e seca. Na classificação da bebida, optou-se por utilizar consumidores como provadores, com o objetivo de analisar a aceitabilidade da bebida pelo mercado consumidor. Como resultados, obteve-se, na classificação por tamanho e determinação de peneira média que os lotes de 12 anos apresentaram-se, com peneira média 15, resultado inferior aos lotes de 3 anos, com peneira média 16. Na classificação comercial e na da bebida, os resultados foram melhores, em geral, para os lotes de 3 anos em diferentes misturas, sem influência dos diferentes estágios de maturação.

  3. Positron emission tomography of the heart

    International Nuclear Information System (INIS)

    Budinger, T.F.; Yano, Y.; Mathis, C.A.; Moyer, B.R.; Huesman, R.H.; Derenzo, S.E.

    1983-01-01

    Positron emission tomography (PET) offers the opportunity to noninvasively measure heart muscle blood perfusion, oxygen utilization, metabolism of fatty acids, sugars and amino acids. This paper reviews physiological principles which are basic to PET instrumentation for imaging the heart and gives examples of the application of positron emission tomography for measuring myocardial flow and metabolism. 33 references, 11 figures, 1 table

  4. MR tomography of the elbow joint

    Energy Technology Data Exchange (ETDEWEB)

    Zwaan, M.; Rinast, E.; Weiss, H.D.; Pressler, M.; Vogel, H.

    1989-03-01

    MR examinations of the elbow joint of three healthy subjects and a comparison with corresponding sections of anatomical preparations show that MR tomography enables not only an excellent differentiation of muscles, tendons and of the articular capsule, but will also visualise vessels and nerve tracts. MR tomography proved superior to the conventional methods in demonstration of separate fragments and inflammatory changes in the bone on examining 11 pathological elbow joints: congenital malformation, osteochondritis dissecans, ostitis, ulnar and radial nerve lesions, completely healed radius fracture and epicondylitis of the radial and ulnar humerus. Epicondylitis could not be demonstrated by MR. Magnetic resonance tomography seems to be the only method that enables direct visualisation of the nerve paths at the elbow joint.

  5. Estudos organizacionais, (descolonialidade e estudos da dependência: as contribuições da Cepal

    Directory of Open Access Journals (Sweden)

    Sergio Wanderley

    Full Text Available O objetivo deste artigo é (revisitar o conceito de dependência como categoria de investigação da (e a partir da América Latina, por meio de uma perspectiva histórica crítica descolonial, a fim de ampliar o espaço de debates em estudos organizacionais e promover alternativas à ordem neoliberal. Este ensaio terá como foco os estudos da dependência realizados pela Comissão Econômica para a América Latina e o Caribe (Cepal durante a década de 1950 e o início dos anos 1960. A perspectiva descolonial é um constructo teórico de autores latino-americanos que se consideram herdeiros da longa tradição do pensamento social crítico da região, na qual a teoria da dependência está inserida. As propostas dos autores da dependência confrontaram as principais teorias ortodoxas do Norte produzidas à época. A partir do conceito de centro-periferia, da denúncia de assimetrias nas relações entre essas regiões, do reconhecimento da interdependência entre desenvolvimento e subdesenvolvimento, o conceito de dependência foi sendo (reelaborado nas décadas de 1950 e 1960 por diversos autores latino-americanos como uma categoria de investigação da realidade da (e a partir da região. Essas investigações tinham por objetivo não somente elaborar constructos teóricos, mas, também, transformar a realidade por meio da criação de diversas organizações e instituições que deveriam servir ao propósito de superar o subdesenvolvimento. A denúncia da historicidade da situação de subdesenvolvimento desnudou o caráter de neutralidade do economicismo das teorias produzidas no Norte e promoveu um encontro teórico entre economia e política que muito tem a contribuir com a área dos estudos organizacionais.

  6. Fast automatic segmentation of anatomical structures in x-ray computed tomography images to improve fluorescence molecular tomography reconstruction.

    Science.gov (United States)

    Freyer, Marcus; Ale, Angelique; Schulz, Ralf B; Zientkowska, Marta; Ntziachristos, Vasilis; Englmeier, Karl-Hans

    2010-01-01

    The recent development of hybrid imaging scanners that integrate fluorescence molecular tomography (FMT) and x-ray computed tomography (XCT) allows the utilization of x-ray information as image priors for improving optical tomography reconstruction. To fully capitalize on this capacity, we consider a framework for the automatic and fast detection of different anatomic structures in murine XCT images. To accurately differentiate between different structures such as bone, lung, and heart, a combination of image processing steps including thresholding, seed growing, and signal detection are found to offer optimal segmentation performance. The algorithm and its utilization in an inverse FMT scheme that uses priors is demonstrated on mouse images.

  7. Estatuto da cidade e juridificação da reforma urbana no Brasil

    OpenAIRE

    Ana Paula Soares Carvalho

    2012-01-01

    O início da década passada foi marcado por um importante evento relacionado ao tratamento das questões urbanas no Brasil. Em dez de julho de 2001, foi promulgada a Lei Federal n 10.257, conhecida como Estatuto da Cidade, que regulamenta o capítulo da política urbana da Constituição de 1988. O Estatuto da Cidade provê suporte legal consistente para aquelas municipalidades comprometidas com o enfrentamento dos problemas sociais e urbanos que afetam diariamente as condições de vida dos habitante...

  8. Axial Tomography from Digitized Real Time Radiography

    Science.gov (United States)

    Zolnay, A. S.; McDonald, W. M.; Doupont, P. A.; McKinney, R. L.; Lee, M. M.

    1985-01-18

    Axial tomography from digitized real time radiographs provides a useful tool for industrial radiography and tomography. The components of this system are: x-ray source, image intensifier, video camera, video line extractor and digitizer, data storage and reconstruction computers. With this system it is possible to view a two dimensional x-ray image in real time at each angle of rotation and select the tomography plane of interest by choosing which video line to digitize. The digitization of a video line requires less than a second making data acquisition relatively short. Further improvements on this system are planned and initial results are reported.

  9. Muons tomography applied to geosciences and volcanology

    Energy Technology Data Exchange (ETDEWEB)

    Marteau, J., E-mail: marteau@ipnl.in2p3.fr [Institut de Physique Nucleaire de Lyon (UMR CNRS-IN2P3 5822), Universite Lyon 1, Lyon (France); Gibert, D.; Lesparre, N. [Institut de Physique du Globe de Paris (UMR CNRS 7154), Sorbonne Paris Cite, Paris (France); Nicollin, F. [Geosciences Rennes (CNRS UMR 6118), Universite Rennes 1, Bat. 15 Campus de Beaulieu, 35042 Rennes cedex (France); Noli, P. [Universita degli studi di Napoli Federico II and INFN sez. Napoli (Italy); Giacoppo, F. [Laboratory for High Energy Physics, University of Bern, SidlerStrasse 5, CH-3012 Bern (Switzerland)

    2012-12-11

    Imaging the inner part of large geological targets is an important issue in geosciences with various applications. Different approaches already exist (e.g. gravimetry, electrical tomography) that give access to a wide range of information but with identified limitations or drawbacks (e.g. intrinsic ambiguity of the inverse problem, time consuming deployment of sensors over large distances). Here we present an alternative and complementary tomography method based on the measurement of the cosmic muons flux attenuation through the geological structures. We detail the basics of this muon tomography with a special emphasis on the photo-active detectors.

  10. A identidade à flor da pele: etnografia da prática da tatuagem na contemporaneidade

    Directory of Open Access Journals (Sweden)

    Andrea Lissett Pérez

    2006-04-01

    Full Text Available No presente artigo, realiza-se uma descrição etnográfica da prática da tatuagem na contemporaneidade, a partir de uma perspectiva que prioriza as noções da prática, das interações e das experiências vividas durante o processo de ser tatuado. A reflexão tenta reconstruir uma visão total da prática da tatuagem que abrange o mundo subjetivo e as dinâmicas sociais como partes constitutivas desse ato. Entre as idéias conclusivas estão, de um lado, o surgimento de uma nova normalidade estética e vivencial no seio da sociedade ocidental e, de outro, a configuração de uma nova subjetividade, a dos "tatuados", como um processo interativo, inovador, emotivo e reflexivo, em que o corpo se converte em uma forma de expressão e construção do sujeito.This article provides a descriptive account of contemporary tattooing, based on a perspective that prioritizes the notion of practice, as well as the interactions and experiences involved in the process of being tattooed. The analysis attempts to rebuild a holistic view of tattooing, combining subjective processes and social dynamics as equally constitutive parts of this activity. Among the conclusions reached are: (a the emergence of tattooing as a new aesthetic norm and a lived experience at the heart of the western society; and (b the configuration of a new subjectivity, the ‘tattooed,’ as an interactive, innovative, emotional and reflexive process in which the body is converted into a form of expressing and constructing the subject.

  11. Optimal Tikhonov Regularization in Finite-Frequency Tomography

    Science.gov (United States)

    Fang, Y.; Yao, Z.; Zhou, Y.

    2017-12-01

    The last decade has witnessed a progressive transition in seismic tomography from ray theory to finite-frequency theory which overcomes the resolution limit of the high-frequency approximation in ray theory. In addition to approximations in wave propagation physics, a main difference between ray-theoretical tomography and finite-frequency tomography is the sparseness of the associated sensitivity matrix. It is well known that seismic tomographic problems are ill-posed and regularizations such as damping and smoothing are often applied to analyze the tradeoff between data misfit and model uncertainty. The regularizations depend on the structure of the matrix as well as noise level of the data. Cross-validation has been used to constrain data uncertainties in body-wave finite-frequency inversions when measurements at multiple frequencies are available to invert for a common structure. In this study, we explore an optimal Tikhonov regularization in surface-wave phase-velocity tomography based on minimization of an empirical Bayes risk function using theoretical training datasets. We exploit the structure of the sensitivity matrix in the framework of singular value decomposition (SVD) which also allows for the calculation of complete resolution matrix. We compare the optimal Tikhonov regularization in finite-frequency tomography with traditional tradeo-off analysis using surface wave dispersion measurements from global as well as regional studies.

  12. Estimation of the patient exposure in tomography

    International Nuclear Information System (INIS)

    Maekoshi, Hisashi; Orito, Takeo; Nishizawa, Kunihide; Koga, Sukehiko.

    1975-01-01

    The author evaluated the estimation method of radiation dose according to surface and intracorporeal dose distribution in chest-tomography. In the study with phantom it was found that the maximum dose area of the skin surface became small and variation of dose in the surrounding area was sharp in proportion to the depth of the cross section. Therefore the author considers that the skin surface dose in tomography should be represented by the highest skin surface dose. In the intracorporeal distribution, the circular tomography undertaken at 10 cm deep from the surface indicated a larger equivalent dose area and higher yielding rate than those in curvilinear tomography. When the phantom filled with water and the one filled with lung equivalent material, cork, were compared; the radiation dose around the radiation field in the phantom with cork was 2-2.5 times the other in circular tomography. However, if the distance from the radiation field became as far as 40 cm, the cork of phantom made little difference. If the radiation dose on the cross section is estimated as 100% in drawing the intracorporeal dose distribution, the results change depending on lung equivalent material. Therefore the author considers that the highest skin dose will be more universal to be taken as the standard. (Kanao, N.)

  13. Cardiac positron tomography

    International Nuclear Information System (INIS)

    Geltmann, E.M.; Roberts, R.; Sobel, B.E.

    1980-01-01

    Positron emission tomography (PET) performed after the administration of the positron-emitting radionuclides carbon-11 ( 11 C), nitrogen-13 ( 13 N), oxygen-15 ( 15 O) and fluorine-18 ( 18 F) has permitted the improved noninvasive assessment of the regional myocardial metabolism of normal physiologic substrates and intermediates and their cogeners. In experimental animals, the rate of oxidation of 11 C-palmitate correlates closely with other indexes of oxygen consumption, and the extraction of 11 C-palmitate (like that of 18 F-fatty acids and 18 F-fluoredoxyglucose) ist markedly diminished in regions of myocardial ischemia. In both experimental animals and in patients, myocardial infarct site and size, determined by positron emission tomography after the intravenous injection of 11 C-palmitate, correlate closely with the electrocardiographic infarct locus and enzymatically estimated infarct size as well as with the location and extent of regional left ventricular wall motion abnormalities. PET offers promise for assessment of flow as well despite the complexities involved. PET with 13 NH 3 appears to provide one useful qualitative index, although this tracer ist actively metabolized. Because of the quantitative capabilities of positron emission tomography and the rapid progress which is being made in the development of fast scan, multi-slice, and gated instrumentation, this technique is likely to facilitate improved understanding and characterization of regional myocardial metabolism and blood flow in man under physiological and pathophysiological conditions. (orig.) [de

  14. CONDICIONANTES DA COMPETITIVIDADE EMPRESARIAL

    Directory of Open Access Journals (Sweden)

    José Luiz Contador

    2010-03-01

    Full Text Available Este trabalho examina teoricamente os fatores determinantes da competitividade do produto e do negócio, imprescindíveis à elaboração de estratégias competitivas que visam à obtenção e sustentação de vantagens competitivas. Esse tema é objeto tanto da área de marketing estratégico quanto da de estratégia empresarial. Nas duas áreas, há um ponto de consenso que afirma que a empresa deve diferenciar sua oferta para conquistar e manter vantagem competitiva. Mas, os estudos conduzidos por meio do modelo de Campos e Armas da Competição revelaram que a empresa pode diferenciar seu produto e/ou serviço de modo mais amplo, levando em consideração, na formulação da sua estratégia competitiva, também o campo da competição, quer do produto, quer dela própria. Assim, o objetivo deste artigo é evidenciar que, para a empresa ser competitiva, além de diferenciar seu produto e/ou seu serviço no sentido tradicional, ela precisa: 1 diferenciar seu produto incluindo a definição em quais campos vai competir em cada segmento; e 2 escolher as armas da competição que irá utilizar e definir a intensidade de cada arma. Para atingir tal objetivo, foram necessários vários conceitos do modelo de Campos e Armas da Competição: campo da competição, arma da competição, tese do modelo, configuração dos campos da competição, campo coadjuvante, produto coadjuvante e par produto-mercado. Como uma proposta inovadora sempre desperta dúvida, é mostrado o processo de validação do modelo de Campos e Armas da Competição e são discutidas sua universalidade, consistência e completude.

  15. Unusual sites of metastatic recurrence of osteosarcoma detected on fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Kabnurkar, Rasika; Agrawal, Archi; Rekhi, Bharat; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2015-01-01

    Osteosarcoma (OS) is the most common nonhematolymphoid primary bone malignancy characterized by osteoid or new bone formation. Lungs and bones are the most common sites of metastases. We report a case where unusual sites of the soft tissue recurrence from OS were detected on restaging fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography scan done post 6 years of disease free interval

  16. Estudo da Concentração de Mercado ao Longo da Cadeia Produtiva da Soja no Brasil

    Directory of Open Access Journals (Sweden)

    Nilson Luiz Costa

    2014-12-01

    Full Text Available O objetivo da presente pesquisa foi mensurar a concentração de mercado ao longo da cadeia produtiva da soja. A partir dessas informações tornou-se possível avaliar se as estratégias para manter e ampliar o poder de mercado e a governança ao longo da cadeia produtiva da soja resultam em sucesso, captação do excedente do produtor rural de soja e competitividade da agroindústria processadora do grão. Neste contexto, foram calculados o Market Share, a Relação de Concentração e do Índice de Herfindahl-Hirschmann. Confirmou-se a hipótese de que o mercado que fornece insumos para os produtores rurais de soja está altamente concentrado. A hipótese de elevada concentração no segmento de aquisição e processamento da soja também foi confirmada.  Concluiu-se que o produtor rural de soja encontra-se em situação de fragilidade econômica, pois: a adquire insumos em mercado oligopolizado e vende a produção em mercado oligopsonizado; b as empresas dominantes estão protegidas por barreiras à entrada. Diante deste cenário e das análises realizadas, cabe ao Estado brasileiro definir a forma de inserção dos agentes nacionais, em especial do produtor rural: se será caracterizado como um instrumento de acumulação do capital internacional ou se participará dos ganhos e se constituirá como agente de desenvolvimento regional. 

  17. Fluorodeoxyglucose positron emission tomography-computed tomography findings in a case of xanthogranulomatous pyelonephritis

    Science.gov (United States)

    Joshi, Prathamesh; Lele, Vikram; Shah, Hardik

    2013-01-01

    Xanthogranulomatous pyelonephritis (XGNP) is an uncommon condition characterized by chronic suppurative renal inflammation that leads to progressive parenchymal destruction. This condition can clinically present as recurrent urinary tract infections, flank pain, hematuria, and occasionally sepsis, and weight loss. This condition is usually associated with obstructing renal calculus. We present 18-fluorodeoxyglucose positron emission tomography-computed tomography (18-FDG PET/CT) findings in an elderly male suffering from pyrexia and weight loss and suspected urinary tract infection. PET/CT findings in this case lead to diagnosis of XGNP. This diagnosis should be kept in mind while evaluating similar symptoms and PET/CT scan findings. PMID:24019680

  18. The role of 18F-fluoro-2-deoxyglucose positron emission tomography/computed tomography in the management of patients with carcinoma of unknown primary.

    Science.gov (United States)

    Deonarine, P; Han, S; Poon, F W; de Wet, C

    2013-08-01

    Carcinoma of unknown primary is one of the ten most frequent cancers worldwide. Its median survival time is less than 10 months. Detecting primary tumour locations and/or occult metastatic lesions may inform definitive treatment and improve patients' prognosis. We aimed to determine: (1) the sensitivity, specificity and accuracy of (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography; (2) its detection rate of primary tumour locations and occult metastases and (3) factors associated with improved survival times. We retrospectively reviewed all cases in the West of Scotland for the period 1 December 2007 to 31 May 2011 that met all our selection criteria: (1) diagnosis of carcinoma of unknown primary; (2) a thorough but negative 'work-up' and (3) (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography report. Statistical methods included frequencies, Kaplan-Meier graphs and log-rank tests to compare survival times. (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography detected primary tumour sites in 19/51 (37.3%) and occult metastases in 28/51 (54.9%) of eligible patients. Its sensitivity, specificity and accuracy were 79.2%, 70.4% and 74.5%, respectively; 20/51 (39.2%) patients died during the study period with a median survival of 8.4 months (range 21.4, SD ± 6.2). The number of metastatic locations was strongly associated with survival (p = 0.002), but detection of a primary tumour site (p = 0.174) or histopathology (p = 0.301) was not. (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography detected occult metastatic sites in the majority and a primary cancer location in a substantial minority of patients. Our results were comparable with international literature and may indicate that (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography have an early role to improve the accuracy of cancer staging and to optimise carcinoma of unknown

  19. A new stereotactic apparatus guided by computed tomography

    International Nuclear Information System (INIS)

    Huk, W.J.

    1981-01-01

    The accurate information provided by computer tomography about existence, shape, and localization of intracranial neoplasms in an early phase and in inaccessible regions have improved the diagnostics greatly, so that these lie far ahead of the therapeutic possibilities for brain tumors. To reduce this wide margin we have developed a new targeting device which makes a stereotactic approach to central lesions under sight-control by computed tomography within the computed tomography-scanner possible. With the help of this simple device we are now able to perform stereotactic procedures for tumor biopsy guided by computed tomography, needling and drainage of abscesses and cysts, and finally for the implantation of radioactive material for the interstitial radiotherapy of inoperable cysts and tumors. (orig.) [de

  20. Gramsci e o debate em torno da filosofia da prÃxis

    OpenAIRE

    Jecson GirÃo Lopes

    2013-01-01

    A presente dissertaÃÃo margeia em torno da discussÃo sobre a maneira pela qual Gramsci debate com os autores de seu tempo, principalmente com Nicolai BukhÃrin, defensor, segundo Gramsci, de um marxismo vulgar, devido sua compreensÃo mecanicista (economicista), fatalista, pelo uso do positivismo na filosofia da prÃxis, marxismo, (materialismo vulgar) e Benedetto Croce, a partir de sua ideia revisionista da filosofia da prÃxis (neo-idealismo: historicismo idealista, conforme Gramsci), como send...

  1. Small scale imaging using ultrasonic tomography

    International Nuclear Information System (INIS)

    Zakaria, Z.; Abdul Rahim, R.; Megat Ali, M.S.A.; Baharuddin, M.Y.; Jahidin, A.H.

    2009-01-01

    Ultrasound technology progressed through the 1960 from simple A-mode and B-mode scans to today M-mode and Doppler two dimensional (2-D) and even three dimensional (3-D) systems. Modern ultrasound imaging has its roots in sonar technology after it was first described by Lord John Rayleigh over 100 years ago on the interaction of acoustic waves with media. Tomography technique was developed as a diagnostic tool in the medical area since the early of 1970s. This research initially focused on how to retrieve a cross sectional images from living and non-living things. After a decade, the application of tomography systems span into the industrial area. However, the long exposure time of medical radiation-based method cannot tolerate the dynamic changes in industrial process two phase liquid/ gas flow system. An alternative system such as a process tomography systems, can give information on the nature of the flow regime characteristic. The overall aim of this paper is to investigate the use of a small scale ultrasonic tomography method based on ultrasonic transmission mode tomography for online monitoring of liquid/ gas flow in pipe/ vessel system through ultrasonic transceivers application. This non-invasive technique applied sixteen transceivers as the sensing elements to cover the pipe/ vessel cross section. The paper also details the transceivers selection criteria, hardware setup, the electronic measurement circuit and also the image reconstruction algorithm applied. The system was found capable of visualizing the internal characteristics and provides the concentration profile for the corresponding liquid and gas phases. (author)

  2. Evaluation of multiple scan average dose (MSAD) levels in computerized tomography in Minas Gerais state, Brazil; Avaliacao dos niveis de dose media em cortes multiplos (MSAD) em tomografia computadorizada no estado de Minas Gerais

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Thessa C., E-mail: alonso@cdtn.br [Centro de Desenvolvimento de Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Vieira, Leandro de A.; Barbosa, Nayra V.; Oliveira, Jeyselaine R. de; Cesar, Adriana C.Z. [Secretaria de Vigilancia Sanitaria de Minas Gerais, Belo Horizonte, MG (Brazil); Silva, Teogenes A. da [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear. Programa de Ciencias e Tecnicas Nucleares

    2014-07-01

    Computed Tomography (CT) grows every year and is a diagnostic method that has revolutionized radiology with advances in procedures for obtaining image. However, the indiscriminate use of this method generates relatively high doses in patients. The diagnostic reference levels (DRLs) is a practical tool to promote the evaluation of existing protocols. The optimization and the periodic review of the protocols are important to balance the risk of radiation. The present study aims to conduct a survey of levels of MSAD of Minas Gerais following the procedures recommended by current Brazilian law. (author)

  3. Estado da arte da S.C.I.E. desde 1951 a 2008 e a sua aplicação como especialidade da engenharia

    OpenAIRE

    Borges, Carlos Avelino Ferreira

    2013-01-01

    No âmbito da dissertação apresentada à Universidade da Madeira para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Engenharia Civil, foi desenvolvida uma pesquisa na área da Segurança Contra Incêndio em Edifícios, abreviadamente designada por SCIE, desde 1951 a 2008 e a sua aplicação como especialidade da Engenharia, designadamente ao nível da fenomenologia da combustão, no que concerne à evolução histórica dos organismos, legislação, normas técnicas e factos his...

  4. Effect of fluid-filled boreholes on resistivity tomography; Hiteiko tomography ni okeru konaisui no eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, Y [DIA Consultants Co. Ltd., Tokyo (Japan)

    1997-10-22

    Theoretical discussions were given on the effect of fluid-filled boreholes on resistivity tomography. The discussions performed incorporation of earth resistance as a method to consider borehole diameters in an FEM calculation using wire elements. The numerical experiment conducted a simulation on the following two objects: resistivity tomography in a horizontal multi-layer structure consisted of layers with resistivity ranging from 10 to 10000 ohm-m, and a model with a slanted low resistivity band existing in a background of 5000 ohm-m. As a result of the discussions, it was made clear that the effect of the boreholes can be corrected by giving earth resistance between the wire elements and natural ground. An improved potential calculating program indicated that the effect of the fluid-filled boreholes in the resistivity tomography generates false images with high resistivity along the bores if the resistivity has high contrast. Incorporating the wire elements into an inverse analysis model reduces the false images and improves the accuracy. 1 ref., 12 figs.

  5. FMT-XCT: in vivo animal studies with hybrid fluorescence molecular tomography-X-ray computed tomography.

    Science.gov (United States)

    Ale, Angelique; Ermolayev, Vladimir; Herzog, Eva; Cohrs, Christian; de Angelis, Martin Hrabé; Ntziachristos, Vasilis

    2012-06-01

    The development of hybrid optical tomography methods to improve imaging performance has been suggested over a decade ago and has been experimentally demonstrated in animals and humans. Here we examined in vivo performance of a camera-based hybrid fluorescence molecular tomography (FMT) system for 360° imaging combined with X-ray computed tomography (XCT). Offering an accurately co-registered, information-rich hybrid data set, FMT-XCT has new imaging possibilities compared to stand-alone FMT and XCT. We applied FMT-XCT to a subcutaneous 4T1 tumor mouse model, an Aga2 osteogenesis imperfecta model and a Kras lung cancer mouse model, using XCT information during FMT inversion. We validated in vivo imaging results against post-mortem planar fluorescence images of cryoslices and histology data. Besides offering concurrent anatomical and functional information, FMT-XCT resulted in the most accurate FMT performance to date. These findings indicate that addition of FMT optics into the XCT gantry may be a potent upgrade for small-animal XCT systems.

  6. Numerical experiment for nonlinear full-wave tomography. 3; Hisenkei full wave tomography no suchi jikken

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, T [Dia Consultants Company, Tokyo (Japan)

    1996-10-01

    Nonlinear full-wave tomography (FWT) is under investigation to improve the estimation accuracy of Vp/Vs distributions. Full-wave tomography is one of the underground structure exploration methods mainly using Tarantola`s nonlinear local optimization method (LOM). Numerical experiment for FWT was carried out assuming relatively weak nonlinear underground structure. In the case of inversion by local optimization method, adequate preconditioning is important. Utilization of geological information is also effective in estimating low-frequency components of a model. As far as data are obtained under proper observation arrangement, even in actual field, precise estimation of Vp/Vs distributions is possible by FWT using explosion in a hole as wave source. In full-wave tomography, selection of observation arrangement is essential for both Vp and Vs. However, the proper arrangement is different between Vp and Vs. Approach to different analyses for Vp and Vs is also necessary by using only proper data for Vp and Vs among obtained data sets. 4 figs.

  7. MANEJO DA IRRIGAÇÃO DA CULTURA DA ALFACE (Lactuca sativa L. ATRAVÉS DO TANQUE CLASSE A

    Directory of Open Access Journals (Sweden)

    ANDRADE JÚNIOR A.S. de

    1997-01-01

    Full Text Available Com o objetivo de avaliar o efeito de diferentes níveis de irrigação, baseados em frações da evaporação do Tanque Classe A (ECA (0,25; 0,50; 0,75 e 1,00 sobre o comportamento produtivo da cultura da alface, variedade "Mesa 659" (tipo americana, cultivada em uma estufa plástica e irrigada por gotejamento, foi conduzido um experimento durante o período de julho a setembro de 1993. O comportamento produtivo foi avaliado através da determinação da matéria fresca (MFP, produtividade (PROD e eficiência do uso de água (EUA. Os resultados de MFP e PROD mostraram resposta quadrática, indicando acréscimo em ambos à medida que aumentaram as lâminas de irrigação aplicadas até o nível 0,75 da ECA, apresentando valores máximos de 818,72 g e 90,97 t.ha-1, respectivamente. Os dados relativos à EUA revelaram resposta linear decrescente, significando que à medida que os níveis de irrigação aumentam ocorre uma diminuição na EUA.

  8. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    International Nuclear Information System (INIS)

    Koh, Kwang Joon; Kim, Kyung A

    2011-01-01

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  9. Aspects of pulmonary histiocytosis X on high resolution computed tomography; Aspectos da histiocitose X pulmonar na tomografia computadorizada de alta resolucao (TCAR)

    Energy Technology Data Exchange (ETDEWEB)

    Costa, N.S.S.; Castro Lessa Angela, M.T. de; Angelo Junior, J.R.L.; Silva, F.M.D.; Kavakama, J.; Carvalho, C.R.R. de; Cerri, G.G. [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Hospital das Clinicas. Inst. do Coracao

    1995-01-01

    Pulmonary histiocytosis X is a disease that occurs in young adults and presents with nodules and cysts, mainly in upper lobes, with consequent pulmonary fibrosis. These pulmonary changes are virtually pathognomonic findings on high resolution computed tomography, that allows estimate the area of the lung involved and distinguish histiocytosis X from other disorders that also produces nodules and cysts. (author). 10 refs, 2 tabs, 6 figs.

  10. Therapy response evaluation with positron emission tomography-computed tomography.

    Science.gov (United States)

    Segall, George M

    2010-12-01

    Positron emission tomography-computed tomography with F-18-fluorodeoxyglucose is widely used for evaluation of therapy response in patients with solid tumors but has not been as readily adopted in clinical trials because of the variability of acquisition and processing protocols and the absence of universal response criteria. Criteria proposed for clinical trials are difficult to apply in clinical practice, and gestalt impression is probably accurate in individual patients, especially with respect to the presence of progressive disease and complete response. Semiquantitative methods of determining tissue glucose metabolism, such as standard uptake value, can be a useful descriptor for levels of tissue glucose metabolism and changes in response to therapy if technical quality control measures are carefully maintained. The terms partial response, complete response, and progressive disease are best used in clinical trials in which the terms have specific meanings and precise definitions. In clinical practice, it may be better to use descriptive terminology agreed upon by imaging physicians and clinicians in their own practice. Copyright © 2010. Published by Elsevier Inc.

  11. Detection of diabetic foveal edema with biomicroscopy, fluorescein angiography and optical coherence tomography Detecção do edema foveal diabético com biomicroscopia, angiografia fluoresceínica e tomografia de coerência óptica

    Directory of Open Access Journals (Sweden)

    Rosana Zacarias Hannouche

    2008-10-01

    Full Text Available To describe different techniques for the detection of diabetic foveal edema. A retrospective review of the detection of diabetic foveal edema. Noncontact lens biomicroscopy is relatively insensitive in mild foveal thickening apparent on optical coherence tomography. Optical coherence tomography measurements can detect early retinal damage in diabetic retinopathy patients.Descrever diferentes técnicas para detecção do edema foveal diabético. Uma revisão da detecção do edema foveal diabético. Biomicroscopia com lente de não contato é relativamente insensível em edema leve aparente na tomografia de coerência óptica. Tomografia de coerência óptica pode detectar precocemente o dano retiniano inicial em pacientes com retinopatia diabética.

  12. Head and neck: normal variations and benign findings in FDG positron emission tomography/computed tomography imaging.

    Science.gov (United States)

    Højgaard, Liselotte; Berthelsen, Anne Kiil; Loft, Annika

    2014-04-01

    Positron emission tomography (PET)/computed tomography with FDG of the head and neck region is mainly used for the diagnosis of head and neck cancer, for staging, treatment evaluation, relapse, and planning of surgery and radio therapy. This article is a practical guide of imaging techniques, including a detailed protocol for FDG PET in head and neck imaging, physiologic findings, and pitfalls in selected case stories. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Da ordem. Da cidade. Da literatura: personagens à beira do "ruim do mundo"

    Directory of Open Access Journals (Sweden)

    Eliana Kuster

    2007-12-01

    Full Text Available As grandes cidades estão doentes. Seus sintomas: a quebra da sociabilidade e a irrupção rotineira da violência. Diante disso, ecoa na sociedade um clamor por ordem. No mesmo momento em que a polícia põe a tropa na rua, os literatos criam personagens que dão voz à sensação crescente de que a cidade está deixando de ser uma referência à constituição das identidades urbanas. É a partir da literatura, em especial da obra do escritor Rubem Fonseca, que iremos perscrutar as possibilidades apresentadas pela cidade para o convívio humano.The great cities are sick. Its indications: the sociability in addition and the routine irruption of the violence. Ahead of this, a outcry for order echoes in the society. At the same moment where the policy goes to the street, the writers create personages who give voice to the increasing sensation of that the city is leaving of being a reference to the constitution of the urban identities. It is from literature, in special of the writer Rubem Fonseca, that we will go to investigate the possibilities presented for the city for the human conviviality.

  14. High-definition velocity-space tomography of fast-ion dynamics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Jacobsen, A.S.

    2016-01-01

    Velocity-space tomography of the fast-ion distribution function in a fusion plasma is usually a photon-starved tomography method due to limited optical access and signal-to-noise ratio of fast-ion Dα (FIDA) spectroscopy as well as the strive for high-resolution images. In high-definition tomography...... information to reconstruct where in velocity space the measurements and the simulation disagree. This alternative approach is demonstrated for four-view as well as for two-view FIDA measurements. The high-definition tomography tools allow us to study fast ions in sawtoothing plasmas and the formation of NBI...

  15. Instrumento mensurador de adesao para hipertensos: contribuicao da Teoria da Resposta ao Item

    Directory of Open Access Journals (Sweden)

    Malvina Thais Pacheco Rodrigues

    2013-06-01

    Full Text Available OBJETIVO: Analisar instrumento de medição da adesão ao tratamento da hipertensão por meio da "Teoria da Resposta ao Item". MÉTODOS: Estudo analítico com 406 hipertensos com complicações associadas, atendidos na atenção básica em Fortaleza, CE, 2011, pela "Teoria da Resposta ao Item". As etapas de execução foram: teste de dimensionalidade, calibração dos itens; tratamento dos dados e construção da escala, analisadas com base no modelo de resposta gradual. Estudo da dimensionalidade do instrumento foi feito pela análise da matriz de correlação policórica e análise fatorial de informação completa. Utilizou-se o software Multilog para calibração dos itens e estimação dos escores. RESULTADOS: Os itens referentes ao tratamento medicamentoso foram os mais diretamente relacionados à adesão, enquanto aqueles referentes ao tratamento não medicamentoso precisam ser reformulados, pois possuíram menor quantidade de informação psicométrica e baixa discriminação. A independência dos itens, o reduzido número de níveis da escala e as baixas variâncias explicadas no ajuste dos modelos mostraram as principais fragilidades do instrumento analisado. A "Teoria da Resposta ao Item" mostrou-se relevante para análise, pois avaliou o respondente quanto à adesão ao tratamento da hipertensão, ao nível de dificuldade dos itens e à sua capacidade de discriminação entre indivíduos com diferentes níveis de adesão, o que gerou maior quantidade de informação. CONCLUSÕES: O instrumento analisado é limitado para medir a adesão ao tratamento da hipertensão, mediante análise pela "Teoria da Resposta ao Item", e necessita de ajustes. A adequada formulação dos itens é importante para medir precisamente o traço latente desejado.

  16. Impacto da abertura comercial sobre a produtividade da indústria brasileira

    OpenAIRE

    Silva, Danielle Barbosa Lopes da

    2004-01-01

    Dentro do atual contexto econômico brasileiro, não existem dúvidas da importância de se discutir o tema produtividade industrial. Dentre os vários benefícios que um aumento da produtividade industrial pode gerar, há de se destacar a manutenção de preços baixos, a redução das taxas de juros e aumento do investimento e consumo. Além disso, o aumento da produtividade industrial ao reduzir o custo da produção e aumentar a sua escala, torna os produtos nacionais com preços mais competitivos no com...

  17. A circulação da experiência da dor em narrativas no Facebook

    Directory of Open Access Journals (Sweden)

    Marlon Santa Maria Dias

    2017-07-01

    Full Text Available Este trabalho reflete alguns aspectos da problemática da circulação na ambiência da midiatização. A partir de material coletado em um grupo de discussão no Facebook sobre a mobilização “Eu não mereço ser estuprada”, analisamos as estratégias discursivas que compõem os processos de enunciação da mobilização dos atores sociais. Apontamos a reconfiguração narrativa na circulação da experiência da dor e a criação de redes interativas de apoio e aconselhamento.

  18. Analysis of the computed tomography in the acute abdomen

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Moraes, Everton; Haygert, Carlos Jesus Pereira; Antunes, Paulo Sergio Pase; Gazzoni, Fernando; Lopes, Luis Felipe Dias

    2007-01-01

    Introduction: This study tends to test the capacity of the computed tomography in assist in the diagnosis and the approach of the acute abdomen. Material and method: This is a longitudinal and prospective study, in which were analyzed the patients with the diagnosis of acute abdomen. There were obtained 105 cases of acute abdomen and after the application of the exclusions criteria were included 28 patients in the study. Results: Computed tomography changed the diagnostic hypothesis of the physicians in 50% of the cases (p 0.05), where 78.57% of the patients had surgical indication before computed tomography and 67.86% after computed tomography (p = 0.0546). The index of accurate diagnosis of computed tomography, when compared to the anatomopathologic examination and the final diagnosis, was observed in 82.14% of the cases (p = 0.013). When the analysis was done dividing the patients in surgical and nonsurgical group, were obtained an accuracy of 89.28% (p 0.0001). The difference of 7.2 days of hospitalization (p = 0.003) was obtained compared with the mean of the acute abdomen without use the computed tomography. Conclusion: The computed tomography is correlative with the anatomopathology and has great accuracy in the surgical indication, associated with the capacity of increase the confident index of the physicians, reduces the hospitalization time, reduces the number of surgeries and is cost-effective. (author)

  19. Anti-amyloid-β-mediated positron emission tomography imaging in Alzheimer's disease mouse brains.

    Directory of Open Access Journals (Sweden)

    Daniel McLean

    Full Text Available Antibody-mediated imaging of amyloid β (Aβ in Alzheimer's disease (AD offers a promising strategy to detect and monitor specific Aβ species, such as oligomers, that have important pathological and therapeutic relevance. The major current limitation of antibodies as a diagnostic and imaging device is poor blood-brain-barrier permeability. A classical anti-Aβ antibody, 6E10, is modified with 10 kDa polyethylene glycol (PEG and a positron emitting isotope, Copper-64 (t(½ = 12.7 h, and intravenously delivered to the TgCRND8 mouse model of Alzheimer's disease. Modification of 6E10 with PEG (6E10-PEG increases accumulation of 6E10 in brain tissue in both TgCRND8 and wild type control animals. 6E10-PEG differentiates TgCRND8 animals from wild type controls using positron emission tomography (PET and provides a framework for using antibodies to detect pathology using non-invasive medical imaging techniques.

  20. Comparison of plain radiography, conventional tomography, and computed tomography in detecting intrathoracic lymph node metastases from lung carcinoma

    International Nuclear Information System (INIS)

    Osborne, D.R.; Korobkin, M.; Ravin, C.E.

    1982-01-01

    Forty-two patients with T2 bronchogenic carcinoma were evaluated with plain radiography, conventional 55 0 oblique hilar and anteroposterior mediastinal tomography, and computed tomography (CT) to compare their accuracy in assessing mediastinal and hilar nodal metastases. Definitive staging was achieved by thoracotomy and histopathological evaluation of resected specimens. All modalities demonstrated about the same accuracy, however, in the 25 patients with hilar and/or mediastinal lymphadenopathy, CT of the mediastinum was more sensitive but not more specific than the other two and conventional tomography was no more accurate than CT for hilar evaluation. Overall, no technicue was accurate enough for routine staging; their value may lie in directing biopsy or in treatment planning in patients with inoperable disease

  1. Neutron beam tomography software

    International Nuclear Information System (INIS)

    Newbery, A.C.R.

    1988-05-01

    When a sample is traversed by a neutron beam, inhomogeneities in the sample will cause deflections, and the deflections will permit conclusions to be drawn concerning the location and size of the inhomogeneities. The associated computation is similar to problems in tomography, analogous to X-ray tomography though significantly different in detail. We do not have any point-sample information, but only mean values over short line segments. Since each mean value is derived from a separate neutron counter, the quantity of available data has to be modest; also, since each datum is an integral, its geometric precision is inferior to that of X-ray data. Our software is designed to cope with these difficulties. (orig.) [de

  2. Da Dor no Corpo à Dor na Alma: O Conceito de Violências Psicológicas da Lei Maria Da Penha

    Directory of Open Access Journals (Sweden)

    Isadora Vier Machado

    2015-05-01

    Full Text Available Este artigo expõe os resultados de pesquisa de campo, realizada entre dezembro de 2010 e julho de 2011 em uma cidade do Sul do Brasil, a respeito da instrumentalização do conceito de violências psicológicas, trazido pela Lei Maria da Penha (Lei 11.340/06, a fim de construir uma leitura da lei a partir deste conceito. Os dados são referentes às/aos agentes que compõem o corpus da polícia, na Delegacia da Mulher e do Ministério Público do município, prioritariamente. Nesses locais, buscou-se compreender como o conceito de violências psicológicas é trabalhado pelas/os agentes e qual o significado teórico-prático que o subjaz. Enfim, coloca-se este dispositivo da lei em posição de questionar a sua própria implementação, de pensar as mudanças que se operam na condição de mulheres em situação de violências e de problematizar as relações entre local e global no campo estudado. A metodologia utilizada foi composta por pesquisa de inspiração etnográfica e levantamento bibliográfico nos campos do Direito, da Psicologia e da Antropologia.

  3. Abdominal alterations in disseminated paracoccidioidomycosis: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Vermelho, Marli Batista Fernandes; Correia, Ademir Silva; Michailowsky, Tania Cibele de Almeida; Suzart, Elizete Kazumi Kuniyoshi; Ibanes, Aline Santos; Almeida, Lanamar Aparecida; Khoury, Zarifa; Barba, Mario Flores, E-mail: marlivermelho@globo.com [Instituto de Infectologia Emilio Ribas (IIER), Sao Paulo, SP (Brazil)

    2015-03-15

    Objective: to evaluate the incidence and spectrum of abdominal computed tomography imaging findings in patients with paracoccidioidomycosis. Materials and methods: retrospective analysis of abdominal computed tomography images of 26 patients with disseminated paracoccidioidomycosis. Results: abnormal abdominal tomographic findings were observed in 18 patients (69.2%), while no significant finding was observed in the other 8 (30.8%) patients. Conclusion: computed tomography has demonstrated to play a relevant role in the screening and detection of abdominal abnormalities in patients with disseminated paracoccidioidomycosis. (author)

  4. O “Estado da Arte” da produção acadêmica sobre o fenômeno da judicialização da saúde no Brasil

    OpenAIRE

    Bittencourt, Guaraci Bragança

    2016-01-01

    A saúde é um tema muito estudado no Brasil, haja vista a grande quantidade de estudos nos campos da saúde pública, saúde coletiva, epidemiologia, bioética, dentre tantos outros. No entanto, o tema da saúde, como um direito, pode ser considerado uma temática recente. Este trabalho realizou uma análise da produção acadêmica, entre os anos de 2010 e 2014 sobre judicialização da saúde, por meio de revisão de literatura, realizada em dois bancos de dados. A produção acadêmica no Brasil tem se dedi...

  5. Positron tomography. Methodology and applications

    International Nuclear Information System (INIS)

    Kellershohn, C.; Comar, D.

    1979-01-01

    Whereas single photon tomography provides a new and rewarding dimension to conventional nuclear medicine, positron tomography makes a new original approach possible of the analysis in vivo of fundamental biological and physiological processes. The main object of both is the sectional representation of the distribution of a radioactive indicator injected into the body system; compared with conventional detectors (gamma cameras and scintigraphic systems) they provide much greater accuracy in localization. The characteristics of these two methods can be presented schematically by comparing their respective advantages and drawbacks [fr

  6. NMF on positron emission tomography

    DEFF Research Database (Denmark)

    Bödvarsson, Bjarni; Hansen, Lars Kai; Svarer, Claus

    2007-01-01

    In positron emission tomography, kinetic modelling of brain tracer uptake, metabolism or binding requires knowledge of the cerebral input function. Traditionally, this is achieved with arterial blood sampling in the arm or as shown in (Liptrot, M, et al., 2004) by non-invasive K-means clustering....... We propose another method to estimate time-activity curves (TAC) extracted directly from dynamic positron emission tomography (PET) scans by non-negative matrix factorization (NMF). Since the scaling of the basis curves is lost in the NMF the estimated TAC is scaled by a vector alpha which...

  7. Positron emission tomography in oncology

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This report describes the current and potential uses of positron emission tomography in clinical medicine and research related to oncology. Assessment will be possible of metabolism and physiology of tumors and their effects on adjacent tissues. Specific probes are likely to be developed for target sites on tumors, including monoclonal antibodies and specific growth factors that recognize tumors. To date, most oncological applications of positron emission tomography tracers have been qualitative; in the future, quantitative metabolic measurements should aid in the evaluation of tumor biology and response to treatment

  8. Direct coronary and sagittal computerized tomography of the pelvis

    International Nuclear Information System (INIS)

    Maier, W.; Bargon, G.

    1981-01-01

    Whereas quite a number of reports have been published on direct coronary and sagittal computed tomography of the cranium, no extensive experience has been collected on multidimensional computerized tomography of the pelvis. In this article, the authors report on their preliminary experiences in direct approximately sagittal and coronary computerized tomography of the pelvis in a group of 76 patients. (orig.) [de

  9. Positron emission tomography - a new approach to brain chemistry

    International Nuclear Information System (INIS)

    Jacobson, H.G.

    1988-01-01

    Positron emission tomography permits examination of the chemistry of the brain in living beings. Until recently, positron emission tomography had been considered a research tool, but it is rapidly moving into clinical practice. This report describes the uses and applications of positron emission tomography in examinations of patients with strokes, epilepsy, malignancies, dementias, and schizophrenia and in basic studies of synaptic neurotransmission

  10. Radiative transport-based frequency-domain fluorescence tomography

    International Nuclear Information System (INIS)

    Joshi, Amit; Rasmussen, John C; Sevick-Muraca, Eva M; Wareing, Todd A; McGhee, John

    2008-01-01

    We report the development of radiative transport model-based fluorescence optical tomography from frequency-domain boundary measurements. The coupled radiative transport model for describing NIR fluorescence propagation in tissue is solved by a novel software based on the established Attila(TM) particle transport simulation platform. The proposed scheme enables the prediction of fluorescence measurements with non-contact sources and detectors at a minimal computational cost. An adjoint transport solution-based fluorescence tomography algorithm is implemented on dual grids to efficiently assemble the measurement sensitivity Jacobian matrix. Finally, we demonstrate fluorescence tomography on a realistic computational mouse model to locate nM to μM fluorophore concentration distributions in simulated mouse organs

  11. USO DA SISTEMATIZAÇÃO DA ASSISTÊNCIA DE ENFERMAGEM (SAE: UMA FERRAMENTA PARA REALIZAÇÃO DA AUDITORIA DE QUALIDADE

    Directory of Open Access Journals (Sweden)

    Maria Izelta da Silva Santos

    2013-04-01

    Full Text Available Realizar uma revisao bibliografica acerca da Sistematização da Assistencia de Enfermagem (SAE como instrumento para auditoria de qualidade. Metodos: Foram revisados 12 artigos cientificos sobre auditoria e 10 artigos sobre SAE, bem como dois livros sobre os assuntos abordados. Esta revisao e de carater descritivo. Resultados: Por meio da pesquisa, tornou-se evidente a correlação da SAE com a auditoria. A SAE bem implementada pode contribuir para uma auditoria de qualidade.

  12. Extracting subsurface fingerprints using optical coherence tomography

    CSIR Research Space (South Africa)

    Akhoury, SS

    2015-02-01

    Full Text Available Subsurface Fingerprints using Optical Coherence Tomography Sharat Saurabh Akhoury, Luke Nicholas Darlow Modelling and Digital Science, Council for Scientific and Industrial Research, Pretoria, South Africa Abstract Physiologists have found... approach to extract the subsurface fingerprint representation using a high-resolution imaging technology known as Optical Coherence Tomography (OCT). ...

  13. Imaging granulomatous lesions with optical coherence tomography

    DEFF Research Database (Denmark)

    Banzhaf, Christina; Jemec, Gregor B E

    2012-01-01

    To investigate and compare the presentation of granulomatous lesions in optical coherence tomography (OCT) images and compare this to previous studies of nonmelanoma skin tumors.......To investigate and compare the presentation of granulomatous lesions in optical coherence tomography (OCT) images and compare this to previous studies of nonmelanoma skin tumors....

  14. Whole brain imaging with Serial Two-Photon Tomography

    Directory of Open Access Journals (Sweden)

    Stephen P Amato

    2016-03-01

    Full Text Available Imaging entire mouse brains at submicron resolution has historically been a challenging undertaking and largely confined to the province of dedicated atlasing initiatives. The has limited systematic investigations into important areas of neuroscience, such as neural circuits, brain mapping and neurodegeneration. In this paper, we describe in detail Serial Two-Photon (STP tomography, a robust, reliable method for imaging entire brains with histological detail. We provide examples of how the basic methodology can be extended to other imaging modalities, such as optical coherence tomography, in order to provide unique contrast mechanisms. Furthermore we provide a survey of the research that STP tomography has enabled in the field of neuroscience, provide examples of how this technology enables quantitative whole brain studies, and discuss the current limitations of STP tomography-based approaches

  15. Data on analysis of coronary atherosclerosis on computed tomography and 18F-sodium fluoride positron emission tomography

    Directory of Open Access Journals (Sweden)

    Toshiro Kitagawa

    2017-08-01

    Full Text Available This article contains the data showing illustrative examples of plaque classification on coronary computed tomography angiography (CCTA and measurement of 18F-sodium fluoride (18F-NaF uptake in coronary atherosclerotic lesions on positron emission tomography (PET. We divided the lesions into one of three plaque types on CCTA (calcified plaque, non-calcified plaque, partially calcified plaque. Focal 18F-NaF uptake of each lesion was quantified using maximum tissue-to-background ratio. This article also provides a representative case with a non-calcified coronary plaque detected on CCTA and identified on 18F-NaF PET/non-contrast computed tomography based on a location of a vessel branch as a landmark. These complement the data reported by Kitagawa et al. (2017 [1].

  16. Aproximações entre Nietzsche e Adorno acerca da massificação da cultura e da vida administrada

    Directory of Open Access Journals (Sweden)

    Francisco Fianco

    Full Text Available Resumo: Pretendemos pensar as relações entre arte e sociedade, tendo sempre em mente a tensão irredutível entre a autonomia e a heteronomia de uma em relação a outra. Para tanto, traçaremos uma análise dos argumentos principais a respeito dessa relação dialética, em dois momentos distintos da reflexão filosófica sobre o tema. Em um primeiro momento, traremos a defesa de uma certa autonomia da arte com referência não apenas à sociedade que a produz, como também aos valores morais que são ensinados através dela, com as reflexões e, sobretudo, com as críticas de Nietzsche sobre suas interpretações da tragédia clássica, a partir principalmente de O Nascimento da Tragédia, para, em um segundo momento, poder traçar um paralelo dessa argumentação com a constatação de Adorno a respeito da instrumentalização e da comercialização da arte, no contexto contemporâneo, expondo algumas das críticas de Nietzsche realizadas no séc. XIX sobre as produções culturais gregas do séc. IV a. C. e contextualizando-as em relação aos fenômenos estéticos contemporâneos.

  17. Aspectos moleculares da anemia falciforme

    Directory of Open Access Journals (Sweden)

    Galiza Neto Gentil Claudino de

    2003-01-01

    Full Text Available No presente artigo abordaram-se vários aspectos relacionados à natureza molecular da anemia falciforme, desordem hematológica de caráter hereditário que acomete expressivo número de indivíduos em várias regiões do mundo. As pesquisas realizadas em torno desta patologia da hemácia, ao longo de quase um século, a partir de 1910, cooperaram para a criação de um novo e importante segmento da ciência, denominado biologia molecular. A descoberta dos polimorfismos da mutação (GAT->GTG no gene que codifica a cadeia beta da hemoglobina, originando diferentes haplótipos da doença, permitiu um melhor e mais amplo conhecimento em torno da heterogeneidade clínica nos pacientes falcêmicos. Analisando a hemoglobina na sua estrutura normal e mutante, sua produção e evolução, pode-se ter um entendimento mais completo da fisiopatologia desta doença e da sua complexidade clínica.

  18. Patterns of brown fat uptake of 18F-fluorodeoxyglucose in positron emission tomography/computed tomography scan

    International Nuclear Information System (INIS)

    Chakraborty, Dhritiman; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2015-01-01

    Fluorodeoxyglucose (FDG) positron emission tomography (PET) has become the common imaging modality in oncological practice. FDG uptake is seen in brown adipose tissue in a significant number of patients. Recognizing the uptake patterns is important for optimal FDG PET interpretation. The introduction of PET/computed tomography (PET/CT) revolutionized PET imaging, bringing much-needed anatomical information. Careful review and correlation of FDG PET images with anatomical imaging should be performed to characterize accurately any lesion having high FDG uptake

  19. Digital radiography in tomography of the facial part of the skull

    International Nuclear Information System (INIS)

    Ibing, H.P.; Vogel, H.; Biebesheimer, V.

    1988-01-01

    In 14 patients the X-ray findings of dental, mandibulary and maxillary roentgen diagnosis were compared with conventional tomography and tomography by digital radiography. All details important for diagnosis were shown by both techniques. Tomography by digital radiography offered a more convenient approach and pictures easier to be interpreted than pictures by conventional tomography. (orig.) [de

  20. Combined computed tomography and fluorodeoxyglucose positron emission tomography in the diagnosis of prosthetic valve endocarditis: a case series.

    Science.gov (United States)

    Bartoletti, Michele; Tumietto, Fabio; Fasulo, Giovanni; Giannella, Maddalena; Cristini, Francesco; Bonfiglioli, Rachele; Raumer, Luigi; Nanni, Cristina; Sanfilippo, Silvia; Di Eusanio, Marco; Scotton, Pier Giorgio; Graziosi, Maddalena; Rapezzi, Claudio; Fanti, Stefano; Viale, Pierluigi

    2014-01-13

    The diagnosis of prosthetic valve endocarditis is challenging. The gold standard for prosthetic valve endocarditis diagnosis is trans-esophageal echocardiography. However, trans-esophageal echocardiography may result in negative findings or yield images difficult to differentiate from thrombus in patients with prosthetic valve endocarditis. Combined computed tomography and fluorodeoxyglucose positron emission tomography is a potentially promising diagnostic tool for several infectious conditions and it has also been employed in patients with prosthetic valve endocarditis but data are still scant. We reviewed the charts of 6 patients with prosthetic aortic valves evaluated for suspicion of prosthetic valve endocarditis, at two different hospital, over a 3-year period. We found 3 patients with early-onset PVE cases and blood cultures yielding Pseudomonas aeruginosa, Staphylococcus epidermidis and Staphylococcus lugdunensis, respectively; and 3 late-onset cases in the remaining 3 patients with isolation in the blood of Streptococcus bovis, Candida albicans and P. aeruginosa, respectively. Initial trans-esophageal echocardiography was negative in all the patients, while fluorodeoxyglucose positron emission tomography showed images suspicious for prosthetic valve endocarditis. In 4 out of 6 patients valve replacement was done with histology confirming the prosthetic valve endocarditis diagnosis. After an adequate course of antibiotic therapy fluorodeoxyglucose positron emission tomography showed resolution of prosthetic valve endocarditis in all the patients. Our experience confirms the potential role of fluoroseoxyglucose positron emission tomography in the diagnosis and follow-up of prosthetic valve endocarditis.

  1. Computed Tomography diagnosis of skeletal involvement in multiple myeloma

    International Nuclear Information System (INIS)

    Scutellari, Pier Nuccio; Galeotti, Roberto; Leprotti, Stefano; Piva, Nadia; Spanedda, Romedio

    1997-01-01

    The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary permeative lesion in the left public bone, which facilitated subsequent biopsy. As for extraosseous localizations, Computed Tomography demonstrated thoracic soft tissue (1 woman) and pelvic (1 man) involvement by myelomtous masses penetrating into surrounding tissues. In our series, only a case of osteosclerotic bone myeloma was observed in the pelvis, associated with lytic abnormalities. Computed Tomography findings do not seem to improve the clinical approach and therapeutic management of the disease. Nevertheless, the authors reccommend Computed Tomography for some myelomatous conditions, namely: a) in the patients with focal bone pain but normal skeletal radiographs; b) in the patients with M protein, bone marrow plasmocytosis and back pain, but with an incoclusive multiple myeloma diagnosis; c) to asses bone spread in the regions which are anatomically complex or difficult to study with radiography and to depict soft tissue involvement; d) for bone biopsy

  2. Limited angle STIM and PIXE tomography of single cells

    International Nuclear Information System (INIS)

    Andrea, T.; Rothermel, M.; Werner, R.; Butz, T.; Reinert, T.

    2010-01-01

    STIM (scanning transmission ion microscopy) tomography has been shown to be a valuable method for the three-dimensional characterization of microsamples. It has, however, rarely been employed for the study of single cells, since a free-standing sample is needed for an ordinary tomography experiment. This requirement places high demands on sample preparation techniques. In this study cells fixated on a substrate rather than free-standing were used for tomography. Since the substrate prevented a full rotation of the sample an algorithm for limited-angle tomography was devised. STIM projections covering only a limited angular range of ca. 120 o were supplemented with simulated projections generated from a back and forth iteration between real space and Radon space. The energy loss caused by the substrate was subtracted from each projection. The cells were reconstructed using filtered backprojection. The surface of the cells as well as some interior structures could be reconstructed. Following the STIM projections a lesser number of PIXE (particle induced X-ray emission) projections were taken in order to obtain information about the elemental distribution of the sample. From the PIXE projections the three-dimensional phosphorus distribution within the cell was reconstructed using limited-angle tomography. Superimposition of the STIM and PIXE tomograms revealed the location of intracellular structures. Whereas STIM tomography is sensitive to density contrast, which are greatest at the surface, PIXE tomography is sensitive to changes in elemental concentration. Hence, the combination of the two methods can be very fruitful, while the limited angle approach can compensate some of the difficulties associated with tomography of single cells, namely preparation difficulties and excessive sample damage.

  3. Problemas na padronização da reação em cadeia da polimerase para diagnóstico da tuberculose pulmonar

    Directory of Open Access Journals (Sweden)

    Bollela Valdes R.

    1999-01-01

    Full Text Available OBJETIVO: Padronizar reação em cadeia da polimerase para diagnóstico de tuberculose pulmonar, comparando os resultados obtidos com as técnicas microbiológicas clássicas, e analisar seu uso numa região de alta prevalência da tuberculose. MÉTODOS: Foram descontaminadas, após a baciloscopia, 42 amostras de escarro de pacientes. Em seguida, procedeu-se ao cultivo em Lowenstein-Jensen e à reação em cadeia da polimerase com "primers" que amplificam um fragmento de 123 pares de base do genoma do Mycobacterium tuberculosis. RESULTADOS: Das 42 amostras de escarro, 10 apresentaram cultura positiva para M. tuberculosis. Dez foram positivas à baciloscopia e 16 mostraram-se positivas na reação em cadeia da polimerase. A sensibilidade e especificidade do teste em relação à cultura foi de 90% e 81%, respectivamente. CONCLUSÕES: A reação em cadeia da polimerase tem sensibilidade comparável à da cultura e pode ser realizada em apenas um dia, resultando em tratamento precoce e melhor controle da doença. A padronização e avaliação de técnicas de biologia molecular no diagnóstico da tuberculose no Brasil é imprescindível na discussão da implantação deste exame na rotina diagnóstica em centros de referência.

  4. Vulnerabilidades sociais e juvenil nos mananciais da zona sul da cidade de São Paulo

    OpenAIRE

    Borelli,Elizabeth

    2012-01-01

    http://dx.doi.org/10.1590/S1414-49802012000100006 Este artigo é um produto parcial da pesquisa “Reflexos da Vulnerabilidade Socioambiental nas Manifestações Musicais dos Jovens Paulistanos da Periferia”, identificando como recorte geográfico a periferia da Zona Sul da cidade de São Paulo. Trata-se de uma região que começou a se formar devido à ocupação populacional desordenada em áreas de manancial, onde a vulnerabilidade social é agravada por situações de risco e degradação ambiental, da...

  5. Da delegacia da mulher à Lei Maria da Penha: Absorção/tradução de demandas feministas pelo Estado

    Directory of Open Access Journals (Sweden)

    Cecília MacDowell Santos

    2012-10-01

    Full Text Available Este artigo examina as respostas do Estado às demandas feministas para o combate à violência doméstica contra mulheres no Brasil desde meados dos anos 1980. São identificados três momentos de mudanças institucionais que direta ou indiretamente moldam e refletem os contextos da atuação estatal: o momento da criação da primeira delegacia da mulher, em 1985; o do surgimento dos Juizados Especiais Criminais, em 1995; e o da promulgação da Lei 11.340, em 2006, conhecida como Lei Maria da Penha. Estes momentos refletem a interação entre múltiplas forças sociopolíticas, sinalizando fluxos e refluxos de políticas públicas e lutas feministas. A análise destes momentos, que pretende contribuir para as teorias feministas do Estado no contexto latino‑americano, revela diferentes formas de atuação estatal e variados graus de absorção/tradução/traição/silenciamento das demandas feministas.

  6. Controle da pérola-da-terra, Eurhizococcus brasiliensis (Hempel) (Homoptera:Margarodidae), através da insetigação

    OpenAIRE

    Hickel, Eduardo R.; Peruzzo, Edegar L.; Schuck, Enio

    2001-01-01

    A pérola-da-terra, Eurhizococcus brasiliensis (Hempel) (Homoptera: Margarodidae), é a principal praga da videira no Sul do Brasil. As estratégias normais de controle desta praga não afetam a população do inseto porque os indivíduos estão no subsolo e desenvolvem um corpo globoso resistente a intempéries. Assim sendo, um ensaio foi conduzido em laboratório para verificar a possibilidade de aplicar a insetigação no controle da pérola-da-terra. Tubos de 50 mm de altura de cano PVC (150 mm fi) fo...

  7. Electrical Impedance Tomography Technology

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal for the Electrical Impedance Tomography Technology (EITT) project is to develop a reliable portable, lightweight device providing two-dimensional...

  8. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  9. The new cold neutron tomography set-up at SINQ

    CERN Document Server

    Baechler, S; Cauwels, P; Dierick, M; Jolie, J; Materna, T; Mondelaers, W

    2002-01-01

    A new cold neutron tomography set-up is operational at the neutron spallation source SINQ of the Paul Scherrer Institute (PSI) in Villigen, Switzerland. The detection system is based on a sup 6 LiF/ZnS:Ag conversion screen and a CCD camera. Several tests have been carried out to characterize the quality of the tomography system, such as homogeneity, reproducibility, L/D-ratio and spatial resolution. The high flux and the good efficiency of the detector lead to very short exposure times. Thus, a typical set of tomography scans can be performed in only 20 min. Then, 3D computed tomography objects were calculated using the filtered back-projection reconstruction method. Initial results of various samples show that cold neutron tomography can be a useful tool for industry, geology and dentistry. Furthermore, suitable applications can be found in the field of archaeology.

  10. Computed tomography in diagnostics of effluent otitis media

    International Nuclear Information System (INIS)

    Imomova, L.S.; Norboev, Z.; Kalandarov, S.Ch.

    2011-01-01

    This article is devoted to computed tomography in diagnostics of effluent otitis media. The purpose of present work is to assess the possibilities of computed tomography method of temporal bone in the diagnostics of otitis media.

  11. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Erdem Sürücü

    2016-10-01

    Full Text Available A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT.

  12. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Science.gov (United States)

    Sürücü, Erdem; Demir, Yusuf; Dülger, Ahmet C.; Batur, Abdüssamed; Ölmez, Şehmus; Kitapçı, Mehmet T.

    2016-01-01

    A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT) scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG) uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT. PMID:27751978

  13. Position emission tomography with or without computed tomography in the primary staging of Hodgkin's lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Loft, Annika; Hansen, Mads

    2006-01-01

    BACKGROUND AND OBJECTIVES: In order to receive the most appropriate therapy, patients with Hodgkin's lymphoma (HL) must be accurately stratified into different prognostic staging groups. Computed tomography (CT) plays a pivotal role in the conventional staging. The aim of the present study...... was to investigate the value of positron emission tomography using 2-[18F]fluoro-2-deoxy-D-glucose (FDG-PET) and combined FDG-PET/CT for the staging of HL patients, and the impact on the choice of treatment. DESIGN AND METHODS: Ninety-nine consecutive, prospectively included patients had FDG-PET and CT...

  14. Value of conventional tomography and computerized tomography in therapy resistant affections of the nasal sinuses

    International Nuclear Information System (INIS)

    Rieden, K.; Frey, M.; Mayer, B.

    1986-01-01

    The informational value of conventional tomography as primary diagnostic method is pointed out in diseases of nasal sinuses resistant to therapy. 5 cases demonstrate the additional information gained by CT-differentiation of soft tissue structures, intraorbital and intracranial expansion. In 78.4% of the examined group of 51 patients conventional tomography allowed the diagnosis of a process limited to the nasal sinuses, further evidence by CT could be omitted. In 11 patients examined by CT additionally, the expansion of the process was defined more precisely and the assumed intraorbital and intracranial growth confirmed. (orig.) [de

  15. O problema da desigualdade social na teoria da sociedade de Niklas Luhmann

    Directory of Open Access Journals (Sweden)

    Roberto Dutra Torres Junior

    Full Text Available A teoria da sociedade de Niklas Luhmann é frequentemente acusada de conservadorismo, visto que negligencia a relevância das estruturas de desigualdade na sociedade moderna. Este artigo propõe uma leitura alternativa dessa teoria, a qual implica uma reconsideração do papel das estruturas de desigualdade para a reprodução dos sistemas sociais. O argumento principal é que as estruturas de desigualdade orientam o modo pelo qual os sistemas sociais selecionam os indivíduos para suas operações. Ao mesmo tempo, é feita uma defesa da tese luhmanniana sobre o primado da diferenciação funcional, pois, enquanto as estruturas de desigualdade podem variar, assumindo formas contingentes, cuja transformação não representa a transformação da sociedade, a diferenciação funcional, ao contrário, representa a própria identidade da sociedade, permanecendo como uma dimensão invariável e necessária nos horizontes de sentido da modernidade.

  16. Isenção da ciência, neutralidade da análise

    Directory of Open Access Journals (Sweden)

    Daniel Menezes Coelho

    2012-01-01

    Full Text Available O artigo discute as relações entre a psicanálise e a ciência, especialmente no que tange aos seus métodos de investigação e trabalho. Para isso, tomamos como objeto a noção de neutralidade, tal como podemos apreendê-la na clínica da psicanálise, para confrontá-la com o que chamamos de isenção no campo da ciência, que não quer dizer outra coisa que a neutralidade proposta lá. Veremos que, apesar da clara filiação da noção psicanalítica para com a noção vinda da ciência, a neutralidade clínica da psicanálise toma outro rumo, que se pode mesmo opor ao sentido do termo na ciência. Enquanto em ciência o termo quer significar um processo de purificação e de seleção, em psicanálise ele surge como a exigência de nada selecionar.

  17. Computed tomography of the skeletal system

    International Nuclear Information System (INIS)

    Maas, R.; Heller, M.

    1990-01-01

    Patients showing severe multiple injuries, require special care and attention in the hospital. In these cases, the range of the diagnostic measures taken subsequent to computed tomography of the cranium must be broadened to include examinations of the vertebral column and pelvic ring for traumatic lesions. Radiological routine procedures are discussed wit hthe view of throwing some light on the problems involved incomputed tomography of the vertebral disks. In degenerative processes associated with spinal stenosis and hypertrophic facets it has been found that angular-sagittal-reconstruction may be quite useful. Computed tomography provides valuable information on morphological factors and has great discriminating power in the diagnosis of skeletal tumours of the extremities. Quantitative computed tomography offers unprecedented possibilities in the diagnosis and treatment of osteoporosis. Here, particular care must be taken to avoid inaccuracies of measurement as a result of incorrectly performed examinations. In malignant bone tumours the method of dynamic scanning permits the success or failure of any radiotherapeutic or chemical measures taken to be evaluated at an early stage. The success or failure of any radiotherapeutic or chemical measures taken to to treat malignant bone tumours can be evaluated at an early stage using the method on dynamic scanning. (orig.) [de

  18. Image characterization metrics for muon tomography

    Science.gov (United States)

    Luo, Weidong; Lehovich, Andre; Anashkin, Edward; Bai, Chuanyong; Kindem, Joel; Sossong, Michael; Steiger, Matt

    2014-05-01

    Muon tomography uses naturally occurring cosmic rays to detect nuclear threats in containers. Currently there are no systematic image characterization metrics for muon tomography. We propose a set of image characterization methods to quantify the imaging performance of muon tomography. These methods include tests of spatial resolution, uniformity, contrast, signal to noise ratio (SNR) and vertical smearing. Simulated phantom data and analysis methods were developed to evaluate metric applicability. Spatial resolution was determined as the FWHM of the point spread functions in X, Y and Z axis for 2.5cm tungsten cubes. Uniformity was measured by drawing a volume of interest (VOI) within a large water phantom and defined as the standard deviation of voxel values divided by the mean voxel value. Contrast was defined as the peak signals of a set of tungsten cubes divided by the mean voxel value of the water background. SNR was defined as the peak signals of cubes divided by the standard deviation (noise) of the water background. Vertical smearing, i.e. vertical thickness blurring along the zenith axis for a set of 2 cm thick tungsten plates, was defined as the FWHM of vertical spread function for the plate. These image metrics provided a useful tool to quantify the basic imaging properties for muon tomography.

  19. Utility of fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography in a child with chronic granulomatous disease

    International Nuclear Information System (INIS)

    Garg, Gunjan; DaSilva, Raphaella; Bhalakia, Avni; Milstein, David M.

    2016-01-01

    We report the fluorodeoxyglucose positron emission tomography/computed tomography (FDG - PET/CT) findings in an 11-month-old boy with suspected milk protein allergy, presented to the hospital with 2-month history of fever of unknown origin and failure to thrive. It showed FDG avid lymphadenopathy above and below the diaphragm and splenic focus, which could represent diffuse inflammatory process or lymphoma. Subsequent jejunal biopsy showed non-necrotizing granulomas

  20. Computed tomography by reconstruction. Brain CT scanning. I. Basic physics, equipment, normal aspects, artefacts

    International Nuclear Information System (INIS)

    Chiras, J.; Palmieri, P.; Saudinos, J.; Salamon, G.

    1980-01-01

    The authors describe the physical basis, apparatus, normal images, and artefacts of computed tomography by reconstruction. Radio-anatomical sections enable clear comprehension of the computed tomography images. Other methods using computer reconstruction are outlined: tomography by Compton effect, tomography by positrons, tomography by gamma emission, tomography by protons, tomography by nuclear magnetic resonance [fr

  1. Reconstruction of an InAs nanowire using geometric tomography

    DEFF Research Database (Denmark)

    Pennington, Robert S.; König, Stefan; Alpers, Andreas

    Geometric tomography and conventional algebraic tomography algorithms are used to reconstruct cross-sections of an InAs nanowire from a tilt series of experimental annular dark-field images. Both algorithms are also applied to a test object to assess what factors affect the reconstruction quality....... When using the present algorithms, geometric tomography is faster, but artifacts in the reconstruction may be difficult to recognize....

  2. Modeling Atom Probe Tomography: A review

    Energy Technology Data Exchange (ETDEWEB)

    Vurpillot, F., E-mail: francois.vurpillot@univ-rouen.fr [Groupe de Physique des Matériaux, UMR CNRS 6634, Université de Rouen, Saint Etienne du Rouvray 76801 (France); Oberdorfer, C. [Institut für Materialwissenschaft, Lehrstuhl für Materialphysik, Universität Stuttgart, Heisenbergstr. 3, 70569 Stuttgart (Germany)

    2015-12-15

    Improving both the precision and the accuracy of Atom Probe Tomography reconstruction requires a correct understanding of the imaging process. In this aim, numerical modeling approaches have been developed for 15 years. The injected ingredients of these modeling tools are related to the basic physic of the field evaporation mechanism. The interplay between the sample nature and structure of the analyzed sample and the reconstructed image artefacts have pushed to gradually improve and make the model more and more sophisticated. This paper reviews the evolution of the modeling approach in Atom Probe Tomography and presents some future potential directions in order to improve the method. - Highlights: • The basics of field evaporation. • The main aspects of Atom Probe Tomography modeling. • The intrinsic limitations of the current method and future potential directions to improve the understanding of tip to image ion projection.

  3. Computerized tomography in orthopaedics and traumatology

    International Nuclear Information System (INIS)

    Boettger, E.; Heckl, R.; Rehabilitations-Krankenhaus Langensteinbach, Karlsbad

    1981-01-01

    Computerized tomography in traumatology is the selected method for the indications mentioned, so that angiographic investigations are only necessary in exceptional cases. Computerized tomography is also better than other methods when diagnozing soft part tumours, however, angiography is still indicated preoperatively for individual cases. CT is only good as additional help to conventional diagnostics with bone tumours. The differential diagnosis cysts-tumour is possible using contrast medium injections. The frequently large soft part share of tumours is recognizable with osteolytic tumours so that a better irradiation and operation planning can be effected. Diseases in the spinal canal can only be assessed with reservation using modern equipment. Lumbar dislocations of the disk can mostly not be sufficiently determined. Perivertebral abscesses can be certainly detected using computerized tomography. This is particularly so for abscesses prior to calcification. (orig.) [de

  4. MACIEZ DA CARNE BOVINA

    Directory of Open Access Journals (Sweden)

    Antonio Bento Mancio

    2006-10-01

    Full Text Available Dentre as características de qualidade da carne bovina, a maciez assume posição de destaque, sendo considerada a característica organoléptica de maior influência na aceitação da carne por parte dos consumidores. A dureza da carne pode ser dividida em dureza residual, causada pelo tecido conjuntivo e outras proteínas do estroma, e dureza de actomiosina, causada pelas proteínas miofibrilares. Dentre os fatores que influenciam a maciez da carne, podem ser destacados a genética, a raça, a idade ao abate, o sexo, a alimentação, o uso de agentes hormonais (?-adrenérgicos e os tratamentos post-mortem. A qualidade final da carne é resultante de tudo o que aconteceu com o animal durante toda a cadeia produtiva. Devem-se assegurar procedimentos adequados de transporte, armazenamento, manipulação, exposição e preparo da carne, a fim de se obter um produto de melhor qualidade. PALAVRAS-CHAVE: Calpaínas, calpastatina, qualidade da carne, rigor mortis, tecido muscular.

  5. APLICABILIDADE DA SISTEMATIZAÇÃO DA ASSISTÊNCIA DE ENFERMAGEM NA ESTRATÉGIA DE SAÚDE DA FAMÍLIA: UMA REVISÃO BIBLIOGRÁFICA

    Directory of Open Access Journals (Sweden)

    Anna Paula Mendonça Barros

    2016-01-01

    Full Text Available Trata-se de uma revisão da literatura realizada no período de 2002 a 2012 cujo objetivo foi revisar e analisar as publicações relacionadas à aplicabilidade da Sistematização da Assistência de Enfermagem na Estratégia de Saúde da Família. Os trabalhos selecionados foram agrupados por similaridade em três categorias temáticas: Funções assistenciais do enfermeiro na ESF; Aplicabilidade da SAE na prática do enfermeiro da ESF; Implementação da ESF e da SAE. Foi demonstrado aumento das publicações nos últimos anos e maior preocupação por parte dos enfermeiros a cerca da temática e que a utilização da SAE na ESF proporciona o estabelecimento de vínculo entre enfermeiro-usuário-família com fortalecimento do elo com a comunidade, de modo que o enfermeiro poderá interligar as informações disponíveis, guiando a assistência prestada a nível individual e familiar. Aplicar a SAE na ESF requer ao enfermeiro dedicação, ousadia e determinação frente às dificuldades em assimilar gerência e assistência, duas funções importantes que o enfermeiro realiza diariamente.

  6. Papel da ultra-sonografia na avaliação da efusão pleural The role of ultrasound in the assessment of pleural effusion

    Directory of Open Access Journals (Sweden)

    Adilson Cunha Ferreira

    2006-04-01

    Full Text Available A efusão pleural, antigamente denominada derrame pleural, é caracterizada pelo acúmulo de líquido no espaço pleural, em decorrência do desequilíbrio entre formação e reabsorção de fluido ou por alteração na drenagem linfática. O propósito desta revisão foi estabelecer a importância da aplicação da ultra-sonografia no diagnóstico de efusão pleural. Os autores discutem a aplicação da ultra-sonografia no diagnóstico e abordagem terapêutica dessa entidade, e ressaltam sua importância nas doenças do tórax, vantagens, limitações e desvantagens em relação a radiografia simples, tomografia computadorizada e exame físico. Discutem, ainda, o conceito de efusão pleural, sua fisiopatologia, morbidade, mortalidade, principais causas e apresentação clínica. A técnica de realização do exame é sistematicamente abordada, tanto pela via torácica quanto abdominal.The pleural effusion, formerly called pleural spill, is an accumulation of fluid in the pleural space, as a consequence of an imbalance between the formation and reabsorption of such fluid, or due to an alteration in the drainage to lymph nodes. The purpose of this bibliographic review is to establish the importance of the use of ultrasound in pleural diffusion diagnosis. The authors discuss the use of ultrasonography in the diagnosis and therapeutic approach of this disease, and stress the importance of ultrasonography in chest diseases diagnosis, its advantages, limitations and disadvantages when compared to the common x-ray, computed tomography and physical examination. The authors also discuss the definition of pleural effusion, its physiopathology, morbidity, mortality, main causes and clinical presentation. The examination technique is systematically approached both by thoracic and abdominal pathways.

  7. Basic principles of 18F-fluoro-deoxyglucose positron emission tomography

    International Nuclear Information System (INIS)

    Standke, R.

    2002-01-01

    Positron emission tomography uses photons to receive regional information about dynamic, physiologic, and biochemical processes in the living body. A positron decay is measured indirectly by the simultaneous registration of both gamma rays created by the annihilation. The event is counted, if two directly opposite located detectors register gamma rays in coincidence. Unfortunately the detectors of a positron emission tomography system do not register only true coincident events. There are also scattered and random coincidences. Different types of positron tomographs are presented and scintillation crystals, which are in use for positron emission tomography are discussed. The 2D- and 3D-acquisition methods are described as well as preprocessing methods, such as correction for attenuation, scatter and dead time. For quantification the relative parameter standard uptake value (SUV) is explained. Finally hybrid systems, such as combined positron emission tomography/computed tomography scanners and the use of computed tomography data for attenuation correction are introduced. (author)

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  10. Modelo para sistemas da qualidade como base da estrategia competitiva

    OpenAIRE

    Marco Antonio Silveira

    1999-01-01

    Resumo: Vários autores propõem a empresa como um sistema em transformação, sendo que esse enfoque sistêmico parece oferecer um meio efetivo de prover as capacidades estratégicas que são valorizadas pelos mercados atuais. Por outro lado, vem crescendo a consciência para o enfoque da qualidade como base da estratégia competitiva, onde esta é associada à lucratividade e incluída no processo de planejamento estratégico, tornando-se um instrumento eficaz de concorrência que, para fazer frente à di...

  11. FIB-SEM cathodoluminescence tomography: practical and theoretical considerations.

    Science.gov (United States)

    De Winter, D A M; Lebbink, M N; Wiggers De Vries, D F; Post, J A; Drury, M R

    2011-09-01

    Focused ion beam-scanning electron microscope (FIB-SEM) tomography is a powerful application in obtaining three-dimensional (3D) information. The FIB creates a cross section and subsequently removes thin slices. The SEM takes images using secondary or backscattered electrons, or maps every slice using X-rays and/or electron backscatter diffraction patterns. The objective of this study is to assess the possibilities of combining FIB-SEM tomography with cathodoluminescence (CL) imaging. The intensity of CL emission is related to variations in defect or impurity concentrations. A potential problem with FIB-SEM CL tomography is that ion milling may change the defect state of the material and the CL emission. In addition the conventional tilted sample geometry used in FIB-SEM tomography is not compatible with conventional CL detectors. Here we examine the influence of the FIB on CL emission in natural diamond and the feasibility of FIB-SEM CL tomography. A systematic investigation establishes that the ion beam influences CL emission of diamond, with a dependency on both the ion beam and electron beam acceleration voltage. CL emission in natural diamond is enhanced particularly at low ion beam and electron beam voltages. This enhancement of the CL emission can be partly explained by an increase in surface defects induced by ion milling. CL emission enhancement could be used to improve the CL image quality. To conduct FIB-SEM CL tomography, a recently developed novel specimen geometry is adopted to enable sequential ion milling and CL imaging on an untilted sample. We show that CL imaging can be manually combined with FIB-SEM tomography with a modified protocol for 3D microstructure reconstruction. In principle, automated FIB-SEM CL tomography should be feasible, provided that dedicated CL detectors are developed that allow subsequent milling and CL imaging without manual intervention, as the current CL detector needs to be manually retracted before a slice can be milled

  12. Computed tomography system

    International Nuclear Information System (INIS)

    Lambert, T.W.; Blake, J.E.

    1981-01-01

    This invention relates to computed tomography and is particularly concerned with determining the CT numbers of zones of interest in an image displayed on a cathode ray tube which zones lie in the so-called level or center of the gray scale window. (author)

  13. Positron emission tomography

    NARCIS (Netherlands)

    Paans, AMJ

    Positron Emission Tomography (PET) is a method for determining biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides as C-11, N-13, O-15 and F-18 and by measuring the annihilation radiation using a

  14. Tópicos da teoria da relatividade

    OpenAIRE

    Fragata, Paulo Renato Ferreira

    2013-01-01

    Dissertação de Mestrado, Matemática para Professores, 25 de Outubro 2013, Universidade dos Açores. Qualquer descrição física da natureza tem por base a especificação da posição e do instante em que decorre determinado acontecimento. Para tal, é necessário recorrer a um sistema de coordenadas, escolhido por cada observador, do modo que ele achar mais pertinente. Dada a generalidade na escolha do sistema de coordenadas, é útil conhecer as regras que nos permitem comparar cálculos feitos em d...

  15. Um levantamento sobre do uso de ferramentas da Web 2.0 entre os estudantes da Ciência da Informação da Universidade Federal de Santa Catarina

    Directory of Open Access Journals (Sweden)

    Eduarda Bodaneze de Oliveira

    2014-04-01

    Full Text Available http://dx.doi.org/10.5007/1518-2924.2014v19n39p153   Nas últimas décadas, puderam-se verificar enormes mudanças nas relações sociais e grandes transformações nos sistemas de comunicação que tornaram mais rápidos os fluxos de informação por meio dos recursos da Internet. A ideia de uma Web 2.0 (a Web colaborativa agrega ideais de colaboração, interação e participação que proporcionam, através de uma organização em rede, uma intensa produção de informação. Este trabalho analisa o uso de ferramentas da Web 2.0 pelos alunos do Departamento de Ciência da Informação da Universidade Federal de Santa Catarina através da caracterização do perfil dos estudantes como usuários destas ferramentas, da identificação das áreas de interesse, das ferramentas mais utilizadas e das principais finalidades de uso das redes sociais Facebook, Twitter e LinkedIn. O estudo concluiu que há um grande potencial, dentro do segmento avaliado, para a troca de informações e difusão de conhecimentos através das ferramentas da Web 2.0. Além disso, estas ferramentas são vistas pelo público-alvo da pesquisa como sendo de grande utilidade, tanto para funções pessoais e de relacionamento quanto para interesses acadêmicos e profissionais.

  16. Cointegrating MiDaS Regressions and a MiDaS Test

    OpenAIRE

    J. Isaac Miller

    2011-01-01

    This paper introduces cointegrating mixed data sampling (CoMiDaS) regressions, generalizing nonlinear MiDaS regressions in the extant literature. Under a linear mixed-frequency data-generating process, MiDaS regressions provide a parsimoniously parameterized nonlinear alternative when the linear forecasting model is over-parameterized and may be infeasible. In spite of potential correlation of the error term both serially and with the regressors, I find that nonlinear least squares consistent...

  17. Frozen Gaussian approximation for 3D seismic tomography

    Science.gov (United States)

    Chai, Lihui; Tong, Ping; Yang, Xu

    2018-05-01

    Three-dimensional (3D) wave-equation-based seismic tomography is computationally challenging in large scales and high-frequency regime. In this paper, we apply the frozen Gaussian approximation (FGA) method to compute 3D sensitivity kernels and seismic tomography of high-frequency. Rather than standard ray theory used in seismic inversion (e.g. Kirchhoff migration and Gaussian beam migration), FGA is used to compute the 3D high-frequency sensitivity kernels for travel-time or full waveform inversions. Specifically, we reformulate the equations of the forward and adjoint wavefields for the purpose of convenience to apply FGA, and with this reformulation, one can efficiently compute the Green’s functions whose convolutions with source time function produce wavefields needed for the construction of 3D kernels. Moreover, a fast summation method is proposed based on local fast Fourier transform which greatly improves the speed of reconstruction as the last step of FGA algorithm. We apply FGA to both the travel-time adjoint tomography and full waveform inversion (FWI) on synthetic crosswell seismic data with dominant frequencies as high as those of real crosswell data, and confirm again that FWI requires a more sophisticated initial velocity model for the convergence than travel-time adjoint tomography. We also numerically test the accuracy of applying FGA to local earthquake tomography. This study paves the way to directly apply wave-equation-based seismic tomography methods into real data around their dominant frequencies.

  18. Resistência genotípica e monitoramento da favorabilidade para ocorrência da ferrugem alaranjada da cana-de-açúcar

    Directory of Open Access Journals (Sweden)

    Kelly Lana Araújo

    2013-12-01

    Full Text Available A ferrugem alaranjada é atualmente uma das principais doenças da cana-de-açúcar. Redução na produtividade de genótipos suscetíveis e intermediários superiores a 40% foram registradas em muitos países, inclusive no Brasil. Este trabalho foi desenvolvido com o objetivo de monitorar os principais genótipos de cana-de-açúcar plantados no Brasil, sob alta pressão de inóculo, quanto à ocorrência e ao desenvolvimento da ferrugem alaranjada. O experimento foi conduzido em área experimental da Usina Univalem, do Grupo Raízen S.A., localizada em Valparaíso (SP. O delineamento experimental utilizado foi em blocos casualizados, com 38 tratamentos (genótipos e quatro repetições. Cada parcela foi constituída por três linhas de cinco metros, espaçadas de 1,4m. Entre cada parcela foi incluída uma linha do genótipo CV14, suscetível à ferrugem alaranjada. A partir da emergência das plantas, todas as parcelas foram monitoradas mensalmente para determinar o início do aparecimento dos sintomas da doença. Depois de constatados os primeiros sintomas, a severidade da ferrugem alaranjada foi quantificada mensalmente na folha +3 em três plantas por parcela. Os meses mais favoráveis para ocorrência da doença foram Fevereiro, Março, Abril e Maio. Foram observados sintomas da ferrugem alaranjada nos genótipos CTC 9, CV 14, RB93-5641, SP842025, RB72-454, SP89-1115, SP81-3250, RB85-5156, CTC 15, RB92-579, SP83-2847 e RB92-5211. Os genótipos SP84-2025 e CV 14 foram os mais suscetíveis à doença. Este trabalho contribui para aperfeiçoar o manejo integrado da ferrugem alaranjada no Brasil, além de auxiliar os programas de melhoramento visando à obtenção de novas variedades resistentes à doença.

  19. Influence of 18F-fluorodeoxyglucose-positron emission tomography on computed tomography-based radiation treatment planning for oesophageal cancer

    International Nuclear Information System (INIS)

    Everitt, C.; Leong, T.

    2006-01-01

    The addition of positron emission tomography (PET) information to CT-based radiotherapy treatment planning has the potential to improve target volume definition through more accurate localization of the primary tumour and involved regional lymph nodes. This case report describes the first patient enrolled to a prospective study evaluating the effects of coregistered positron emission tomography/CT images on radiotherapy treatment planning for oesophageal cancer. The results show that if combined positron emission tomography/CT is used for radiotherapy treatment planning, there may be alterations to the delineation of tumour volumes when compared to CT alone. For this patient, a geographic miss of tumour would have occurred if CT data alone were used for radiotherapy planning Copyright (2006) Blackwell Publishing Asia Pty Ltd

  20. Estudo e otimização da produção da dextranasacarase e caracterização da dextrana produzida por Leuconostoc mesenteroides FT045B

    OpenAIRE

    Vettori, Mary Helen Palmuti Braga [UNESP

    2011-01-01

    Um estudo comparativo de onze métodos para determinação da atividade da dextranasacarase e de enzimas relacionadas foi realizado. Atualmente existem dois métodos usualmente empregados na determinação da atividade da dextranasacarase. Um método relativamente difundido para a reação da enzima com a sacarose consiste na medição dos valores redutores da D-frutose pelo reagente 3,5-dinitrosalicilato (DNS). Outro método é a reação da enzima com 14Csacarose, pela adição de uma alíquota da reação em ...

  1. ASPECTOS RELEVANTES DO INSTITUTO DA INVERSÃO DO ÔNUS DA PROVA

    OpenAIRE

    João Alberto Mendes Bezerra Júnior

    2017-01-01

    O presente trabalho pretende contribuir, ainda que minimamente, com o mundo jurídico, no que diz respeito ao instituto da inversão do ônus da prova, previsto no art. 6º, VIII do Código Brasileiro de Defesa do Consumidor, sob o enfoque do Direito Constitucional. Além de abordar o alcance dos requisitos impostos por esse dispositivo legal, o estudo trata do momento em que a inversão do ônus da prova deve ocorrer no processo civil, trazendo novas luzes a respeito, mormente como reforço à tese da...

  2. O uso da teoria da visão baseada em recursos em propriedades rurais: uma revisão sistemática da literatura

    Directory of Open Access Journals (Sweden)

    Daniela Moreira de Carvalho

    2014-09-01

    Full Text Available A teoria da Visão Baseada em Recursos (VBR tem se destacado como uma das mais importantes correntes teóricas da estratégia. O uso da teoria dos recursos mostra-se promissor para a análise das propriedades rurais, permitindo avançar no conhecimento do potencial a ser explorado em torno dos recursos internos. No presente estudo, contribui-se com um levantamento da literatura sobre os principais recursos e/ou fatores-chave determinantes para o desempenho de propriedades rurais por meio da análise de trabalhos que utilizaram a teoria da VBR como base teórica. Com esse levantamento, pretende-se verificar quais recursos foram considerados estratégicos pela literatura da área. A metodologia utilizada foi de revisão sistemática. Os resultados indicaram que o uso da teoria em estudos de empreendimentos agropecuários ainda é incipiente. Foram levantados 14 artigos em fazendas em geral e, dentre esses, três estudos em fazendas produtoras de leite que mostram resultados consistentes quanto ao impacto dos recursos sobre o desempenho. Recursos humanos e organizacionais foram os mais citados como estratégicos e fundamentais para o desempenho. Os recursos físicos foram citados mais vezes em artigos que analisaram o meio rural se comparado à literatura geral do uso da VBR, talvez pela maior dependência de aspectos naturais no desempenho das fazendas em relação aos outros setores da economia. Contudo, devido ao pequeno número de trabalhos encontrados e à diversidade de abordagens em torno da teoria, não é possível realizar inferências, somente concluir que existe um gap de conhecimento nessa área que deve ser suprido por meio de novas e amplas pesquisas.

  3. Disruption of the 37-kDa/67-kDa laminin receptor gene in bovine ...

    African Journals Online (AJOL)

    ... gene encoding for the prion binding site in bovine fetal fibroblasts. The heterozygous BFF are ready to be used in producing homozygous cattle, which will be applied to study the interaction between prion and the 37-kDa/67-kDa LRP/LR. Key words: Prion, PrPC, PrPSc, 37-kDa/67-kDa laminin receptor, gene targeting.

  4. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography; Positronenemissionstomographie bei malignen Tumoren im Kopf- und Halsbereich. Beurteilung der diagnostischen Wertigkeit der Positronenemissionstomographie im Vergleich zur Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Kettler, Nele

    2011-12-02

    Imaging methods for early, accurate diagnosis and aftercare of malignant growths is currently one of the most important research topics. The objective of this thesis is to evaluate the diagnostic value of FDG-positron emission tomography by comparison with computed tomography for patients with squamous cell carcinoma, malignant melanoma or sarcoma at head and neck. Measurement criteria are sensitivity and specificity. A retrospective evaluation of 100 examinations on 85 patients of University clinic Aachen was performed. The examination reports were supported by reports from histology, positron emission tomography and computed tomography. In each case, the histological results were assumed to provide a reliable benchmark. Sensitivity and specificity for the primary tumour site, metastatic lymphatic nodes and defined anatomic structures were compared across all patients. Comparisons were also performed on sub groups separated by gender, cancer type and the time and frequency at which tumours arose. The statistic analysis was done with MedCalc. Results: The results for sensitivity and specificity of the primary tumour site were 86.42% and 42.86%, and 64.71% and 66.07%, for positron emission tomography and computed tomography respectively. The results for the lymphatic nodes were 51.52% and 92.86% and 64.71% and 66.07%. When the constituent anatomic structures were evaluated separately, the specificity was significantly higher. The separation by gender showed no difference. Because the classification by tumor type resulted in samples that were of varying size, a comparison was difficult. For the diagnosis of primary tumours, the examination with positron emission tomography was superior, whereas computed tomography proved more effective for the diagnosis of recurrent tumours. For the diagnosis of the main tumour site, both methods were shown to be equally suitable. For the assessment of lymphatic nodes, positron emission tomography was superior to computed tomography

  5. Development of a proton Computed Tomography Detector System

    Energy Technology Data Exchange (ETDEWEB)

    Naimuddin, Md. [Delhi U.; Coutrakon, G. [Northern Illinois U.; Blazey, G. [Northern Illinois U.; Boi, S. [Northern Illinois U.; Dyshkant, A. [Northern Illinois U.; Erdelyi, B. [Northern Illinois U.; Hedin, D. [Northern Illinois U.; Johnson, E. [Northern Illinois U.; Krider, J. [Northern Illinois U.; Rukalin, V. [Northern Illinois U.; Uzunyan, S. A. [Northern Illinois U.; Zutshi, V. [Northern Illinois U.; Fordt, R. [Fermilab; Sellberg, G. [Fermilab; Rauch, J. E. [Fermilab; Roman, M. [Fermilab; Rubinov, P. [Fermilab; Wilson, P. [Fermilab

    2016-02-04

    Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

  6. Development of Axial Tomography for Steam Explosion Study

    International Nuclear Information System (INIS)

    Lee, Jae Young; Seo, Shi Won; Song, Jin Ho

    2006-01-01

    Visual understanding of complicated system leads us often to the intuitive enlightenment of the invisible causes of the effect. When it is formulated based on the rigorous mathematics, the produced formula or correlation will be very useful in design and analysis of the engineering system. In this point of view, the tomography technology can be a tool to meet such a purpose. However, the traditional hard ray tomography using high energy radiation cannot meet the case due to heavy shielding structure which obstructs access of the sensing unit to the very complicated and limited space. Therefore, the recent development of the electric tomography is noteworthy in the application to the industrial process monitoring. It has the merit not only of low cost but also of easier access to the limited space than the hard ray tomography

  7. Magnetic resonance tomography of the temporo-mandibular joints

    International Nuclear Information System (INIS)

    Katzberg, R.W.; Burgener, F.A.

    1986-01-01

    79 patients aged 6 to 66 years (9 men and 70 women) with abnormalities of the TMJs were examined by magnetic resonance tomography (132 joints) and the results were compared with CT (16 joints) and resonance tomography showed forward luxation of the meniscus in 82 joints (62%). In 34 joints (26%) the meniscus spontaneously resumed normal position when the mouth was open, but in 48 joints (36%) the displacement was permanent. The accuracy of resonance tomography was equal to that of arthrography and superior to CT. It was particularly suitable for follow-up examination after surgery (23 cases) when invasive arthrography would be contraindicated or difficult. Because of the high resolution of the soft tissue components in the TMJ, resonance tomography should be able to diagnose inflammatory and degenerative changes in the meniscus and ligaments. (orig.)

  8. INTEGRAÇÃO AFRICANA: DA ORGANIZAÇÃO DA UNIDADE AFRICANA À UNIÃO AFRICANA

    OpenAIRE

    Diallo, Alfa Oumar

    2015-01-01

    Desde Kwamé N´Krumah a unidade da África era um grande desejo. A Organização da Unidade Africana (OUA) servia aos olhares de alguns na pobreza moral e material do continente. Destaca-se, que dentro da OUA, alguns fundadores militavam em favor da instituição dos Estados Unidos da África enquanto que outros pregavam, ao contrário, pela fragmentação dos Estados-Nações sob uma forma organizacional. Os Estados Unidos da África certamente seriam limitados à exploração contínua deste continente, mas...

  9. Longitudinal emission tomography of thyroid and heart

    International Nuclear Information System (INIS)

    Giessen, J.W. van.

    1986-01-01

    In this thesis three devices are discussed for longitudinal emission tomography, one of which has been developed for myocardial imaging and the other two for thyroid imaging. Longitudinal emission tomography is a technique which enables three-dimensional reconstruction of the radioactivity distribution within an organ from two-dimensional distributions on a detector surface. In Ch. 1 a general survey is given of the clinical environment in which the devices will be used. Ch. 2 discusses a well-known technique for myocardial imaging: seven-pinhole tomography. In Ch. 3 this technique is applied to imaging of the thyroid. Three different reconstruction methods have been applied to the data collected with the system (from phantoms as well as from patients) and the results have been evaluated. Ch. 4 discusses simulation studies which were carried out in order to investigate the potentialities of a time-coded aperture (TCA) system designed for thyroid tomography. In Ch. 5 a prototype is tested of the time coded aperture in a clinical environment. The last chapter presents a comparison between the (thyroid) 7P collimator and the TCA device. (Auth.)

  10. Computed tomography diagnosis of hepatocellular carcinoma rupture haemorrhage

    International Nuclear Information System (INIS)

    Zhi Weike; Jiang Bin; Liu Jinquan; Li Sixia; Zhu Zhichang

    2004-01-01

    Objective: To evaluate the diagnostic value of hepatocellular carcinoma rupture hemorrhage using Computed Tomography. Methods: Six cases diagnosed hepatocellular carcinoma rupture hemorrhage were analyzed by morphic and histologic method and investigated the key point of scan in diagnosis. Result: The correct rate of hepatocellular carcinoma rupture hemorrhage by Computed Tomography is above 83 percent, it characteristic representation is strip and would high-density shadow after enhancement. Conclusion: The characteristic representation of hepatocellular carcinoma rupture hemorrhage is attain by Computed Tomography, which provides effective operation evidences for clinical operation. (authors)

  11. Computer tomography in complex diagnosis of laryngeal cancer

    International Nuclear Information System (INIS)

    Savin, A.A.

    1999-01-01

    To specify the role of computer tomography in the diagnosis of malignant of the larynx. Forty-two patients with suspected laryngeal tumors were examined: 38 men and 4 women aged 41-68 years. X-ray examinations included traditional immediate tomography of the larynx. Main X-ray and computer tomographic symptoms of laryngeal tumors of different localizations are described. It is shown that the use of computer tomography in complex diagnosis of laryngeal cancer permits an objective assessment of the tumor, its structure and dissemination, and of the regional lymph nodes [ru

  12. Stereo-tomography in triangulated models

    Science.gov (United States)

    Yang, Kai; Shao, Wei-Dong; Xing, Feng-yuan; Xiong, Kai

    2018-04-01

    Stereo-tomography is a distinctive tomographic method. It is capable of estimating the scatterer position, the local dip of scatterer and the background velocity simultaneously. Building a geologically consistent velocity model is always appealing for applied and earthquake seismologists. Differing from the previous work to incorporate various regularization techniques into the cost function of stereo-tomography, we think extending stereo-tomography to the triangulated model will be the most straightforward way to achieve this goal. In this paper, we provided all the Fréchet derivatives of stereo-tomographic data components with respect to model components for slowness-squared triangulated model (or sloth model) in 2D Cartesian coordinate based on the ray perturbation theory for interfaces. A sloth model representation means a sparser model representation when compared with conventional B-spline model representation. A sparser model representation leads to a smaller scale of stereo-tomographic (Fréchet) matrix, a higher-accuracy solution when solving linear equations, a faster convergence rate and a lower requirement for quantity of data space. Moreover, a quantitative representation of interface strengthens the relationships among different model components, which makes the cross regularizations among these model components, such as node coordinates, scatterer coordinates and scattering angles, etc., more straightforward and easier to be implemented. The sensitivity analysis, the model resolution matrix analysis and a series of synthetic data examples demonstrate the correctness of the Fréchet derivatives, the applicability of the regularization terms and the robustness of the stereo-tomography in triangulated model. It provides a solid theoretical foundation for the real applications in the future.

  13. Cellular imaging electron tomography and related techniques

    CERN Document Server

    2018-01-01

    This book highlights important techniques for cellular imaging and covers the basics and applications of electron tomography and related techniques. In addition, it considers practical aspects and broadens the technological focus by incorporating techniques that are only now becoming accessible (e.g. block face imaging).  The first part of the book describes the electron microscopy 3D technique available to scientists around the world, allowing them to characterize organelles, cells and tissues. The major emphasis is on new technologies like scanning transmission electron microscopy (STEM) tomography, though the book also reviews some of the more proven technologies like electron tomography. In turn, the second part is dedicated to the reconstruction of data sets, signal improvement and interpretation.

  14. An industrial demonstration of computer assisted tomography

    International Nuclear Information System (INIS)

    Lupton, L.R.

    1985-09-01

    Computerized tomography (CT) is a nondestructive testing technique for generating quantitative density (linear attenuation coefficient) maps of a cross section through an object. By using a series of parallel tomographic images taken at different elevations, a three-dimensional (3-D) map of the object can be obtained. To demonstrate the power of tomography, a 3-D region of a motorcycle carburetor has been imaged using twenty-four parallel two-dimensional images. From these data, new images in planes orthogonal to the original planes have been generated, thereby improving the user's ability to visualize the position of components within the carburetor. The data have also been used to demonstrate the relationship between tomography and radiography

  15. Doppler tomography in fusion plasmas and astrophysics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Heidbrink, W. W.

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion Dα (FIDA) spectroscopy measurements in magnetically confined plasma......, the Dα-photons are likewise Doppler-shifted ultimately due to gyration of the fast ions. In either case, spectra of Doppler-shifted line emission are sensitive to the velocity distribution of the emitters. Astrophysical Doppler tomography has lead to images of accretion discs of binaries revealing bright...... and limits, analogies and differences in astrophysical and fusion plasma Doppler tomography and what can be learned by comparison of these applications....

  16. Melanotic neuroectodermal tumor of infancy (progonoma): a case report emphasizing the computed tomography findings and literature review; Tumor neuroectodermico melanocitico da infancia (progonoma): relato de caso enfatizando os aspectos tomograficos e revisao da literatura

    Energy Technology Data Exchange (ETDEWEB)

    Araujo Junior, Cyrillo Rodrigues de; Carvalho, Tarcisio Nunes; Fraguas Filho, Sergio Roberto; Costa, Marlos Augusto Bitencourt; Borba, Ana Olivia Cardoso; Figueiredo, Sizenildo da Silva; Machado, Marcio Martins; Teixeira, Kim-Ir-Sen Santos [Goias Univ., Goiania, GO (Brazil). Hospital das Clinicas. Servico de Diagnostico por Imagem]. E-mail: radiologia@brturbo.com

    2004-12-01

    The melanotic neuroectodermal tumor of infancy, also known as progonoma, is a rare benign disease of neural crest origin that occurs within the first year of life and affects mainly the maxilla. The authors report a case of a 10-month-old child presenting with this uncommon tumor in the maxilla, emphasizing the diagnostic findings on computed tomography, and present a literature review. (author)

  17. Ambient seismic noise tomography for exploration seismology at Valhall

    Science.gov (United States)

    de Ridder, S. A.

    2011-12-01

    Permanent ocean-bottom cables installed at the Valhall field can repeatedly record high quality active seismic surveys. But in the absence of active seismic shooting, passive data can be recorded and streamed to the platform in real time. Here I studied 29 hours of data using seismic interferometry. I generate omni-directional Scholte-wave virtual-sources at frequencies considered very-low in the exploration seismology community (0.4-1.75 Hz). Scholte-wave group arrival times are inverted using both eikonal tomography and straight-ray tomography. The top 100 m near-surface at Valhall contains buried channels about 100 m wide that have been imaged with active seismic. Images obtained by ASNT using eikonal tomography or straight-ray tomography both contain anomalies that match these channels. When continuous recordings are made in real-time, tomography images of the shallow subsurface can be formed or updated on a daily basis, forming a very low cost near-surface monitoring system using seismic noise.

  18. Tomography in nuclear medicine. Proceedings of an international symposium

    International Nuclear Information System (INIS)

    1996-01-01

    Single photon emission computed tomography (SPECT) is currently being used universally in clinical practice, while positron emission tomography (PET), originally developed as a technique for research, has also gradually moved from the research laboratory to the clinical environment. However, there are significant differences in nuclear medicine capabilities, especially in tomography, between developed and developing countries. The present status and future prospects of nuclear medicine tomography were the main topics of discussion at this latest international symposium, organized by the IAEA in co-operation with the World Health Organization and held in Vienna from 21 to 25 August 1995. The purpose of the meeting was to share experience and information on new developments and clinical applications of two promising tomographic techniques: SPECT and PET. Eight invited papers and 34 regular papers from 23 countries were presented. In addition, there was a panel discussion on the future and direction of tomography in nuclear medicine for developing countries. Refs, figs, tabs

  19. GESTÃO DA INOVAÇÃO EM EMPRESAS DE TECNOLOGIA DA INFORMAÇÃO E COMUNICAÇÃO NO ESTADO DA BAHIA

    Directory of Open Access Journals (Sweden)

    Luan Carlos Santos Silva

    2014-12-01

    Full Text Available O presente artigo traz para a discussão, reflexões acerca do entendimento da gestão da inovação em empresas de tecnologia da informação e comunicação (TICs que em muitas abordagens não levam em consideração a especificidade região e do mercado onde elas atuam, bem como o relacionamento direto com os processos da inovação. A pesquisa foi qualitativa e do ponto de vista por sua natureza, constitui-se como aplicada. Sendo caracterizada como uma pesquisa descritiva. O objetivo geral do artigo foi analisar o processo de gestão da inovação nas empresas de Tecnologia da Informação e Comunicação (TICs do Pólo de Informática de Ilhéus no Estado da Bahia. E finaliza-se destacando que para enfrentar os desafios no mercado, as empresas do Pólo de Informática devem inovar seus processos continuamente, e adquirindo novos conhecimentos organizacionais para terem uma postura empreendedora e inovadora junto ao mercado, a execução, manutenção e ampliação dessas ações tornam-se fundamentais para um maior fortalecimento das empresas de (TICs no Estado da Bahia.

  20. Aquiles e Mêmnon face à morte: um estudo da cena da Psicostasia na pintura da cerâmica ática

    Directory of Open Access Journals (Sweden)

    José Geraldo Costa Grillo

    2014-11-01

    Full Text Available O autor estuda as pinturas da cerâmica ática, com a representação da Psicostasia de Aquiles e Mêmnon, respon­dendo à questão do contexto, no interior do qual ela adquire sentido. Defende a ideia de que ela está imersa na esfera reli­giosa e ligada ao tema da morte, especificamente ao ideal he­roico da bela morte, o qual vem ser o meio de o guerreiro es­capar do fim que a morte representa, uma vez que esta morte heroica lhe permite permanecer vivo na memória de seu povo.

  1. Evaluation of the repeatability of dosimetric parameters of a linear accelerator beam; Avaliacao da repetibilidade de parametros dosimetricos do feixe de um acelerador linear

    Energy Technology Data Exchange (ETDEWEB)

    Morelli, Humberto A.S.; Oliveira, Harley F. de; Silva, Maelson do N.; Pavoni, Juliana F., E-mail: h.morelli@hotmail.com [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Servico de Radioterapia

    2016-07-01

    This study aims to evaluate the repeatability of symmetry and flatness of the photon beam of 6 MV linear accelerator Oncor Impression, Siemens, from the Radiotherapy Department of the Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto - USP. In total they were collected 102 measures, weekly, through two-dimensional detector of ionization chambers, Matrixx Evolution, IBA Dosimetry, connected to a computer with software OmniProI'mrt. The isocenter of the linear accelerator was placed in the center of the sensitive volume of the detector with solid water plates above and below these. Data were collected with 100 UM, with field size 10 x 10 cm². The flatness and symmetry values were calculated by the software used. The first measurement of this work was used as reference, the others were compared with it, taking into account the values of permissible variation for these parameters. The minimum, maximum and average value were analyzed. The literature indicates that the flatness and symmetry values should not vary by more than 2 and 3%, respectively. The results of this work show that the values of these parameters for the linear accelerator study are within the permissible variations in protocols and are therefore able to appropriate clinical use. (author)

  2. Computed tomography

    International Nuclear Information System (INIS)

    Andre, M.; Resnick, D.

    1988-01-01

    Computed tomography (CT) has matured into a reliable and prominent tool for study of the muscoloskeletal system. When it was introduced in 1973, it was unique in many ways and posed a challenge to interpretation. It is in these unique features, however, that its advantages lie in comparison with conventional techniques. These advantages will be described in a spectrum of important applications in orthopedics and rheumatology

  3. Computerized tomography

    International Nuclear Information System (INIS)

    Caille, J.M.; Salamon, G.

    1980-01-01

    As X-ray Ct becomes more commonplace, other techniques of investigation using roughly comparable hardware and software have appeared. Positron-Emission Tomography already provides indispensable physiological and physio-pathological information. Similarly, in the histo-chemical field, Nuclear Magnetic Resonance seems very promising. Some of these new techniques will no doubt shortly be considered as essential as CT in establishing accurate diagnoses non-invasively. (orig./VJ) [de

  4. Computed Tomography Observer Agreement in Staging Malignant Lymphoma

    NARCIS (Netherlands)

    de Jong, Antoinette; Kwee, Thomas C.; Quarles van Ufford, Henriëtte M. E.; Beek, Frederik J. A.; Quekel, Lorentz G. B. A.; de Klerk, John M. H.; Zijlstra, Josée M.; Fijnheer, Rob; Ludwig, Inge; Kersten, Marie José; Stoker, Jaap; Nievelstein, Rutger A. J.

    2016-01-01

    To determine pretreatment computed tomography observer agreement in patients with newly diagnosed lymphoma. Forty-nine computed tomography scans were reviewed by 3 experienced radiologists, with each scan assessed twice by 1 observer. Predefined nodal and extranodal regions were assessed, and Ann

  5. Cranial computed tomography in psychiatry

    International Nuclear Information System (INIS)

    Falkai, P.; Bogerts, B.

    1993-01-01

    Computed tomography has gained importance as a diagnostic tool in psychiatry to exclude structural brain pathology, but has passed on its role in research to magnetic resonance tomography. It helps to distinguish between senile dementia of Alzheimer type and multi-infarct dementia. The enlargement of the ventricular system and cortical sulci is well established in schizophrenic and affective psychosis. Some alcohol addicts show a considerable degree of cerebral atrophy, only exceeded by demented patients, but this condition is potentially reversible. To screen psychiatric patients by CT is recommendable, as 2-10% of hospitalized psychiatric patients have structural brain disease. (orig.) [de

  6. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Marchiori, Edson; Oliveira, Hugo

    2010-01-01

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  7. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    Energy Technology Data Exchange (ETDEWEB)

    Hochhegger, Bruno, E-mail: brunohochhegger@googlemail.co [Hospital Moinhos de Vento, Porto Alegre, RS (Brazil); Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia; Irion, Klaus L. [Liverpool Heart and Chest Hospital, Liverpool (United Kingdom); Oliveira, Hugo [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil)

    2010-07-15

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  8. Endocardite acuta da Staphylococcus haemolyticus meticillino sensibile, con recidiva dopo trattamento da ceppo meticillino resistente

    Directory of Open Access Journals (Sweden)

    Giacomo Magnani

    2005-03-01

    Full Text Available Le endocarditi su valvole native (NVE da Stafilococchi coagulasi negativi (CoNS presentano un andamento aggressivo simile a quello da Staphylococcus aureus e sono difficili da trattare per l’alta incidenza da parte dei CoNS di resistenza a oxacillina.Viene riportato un caso di NVE da Staphylococcus haemolyticus meticillino sensibile, con risposta iniziale favorevole al trattamento con oxacillina, ma con successiva recidiva a distanza di tre mesi legata comparsa di ceppo oxacillino-resistente. L’ipotesi è che l’infezione sia stata sostenuta da una popolazione batterica con fenotipo eteroresistente, che in seguito al trattamento antibiotico ha sviluppato resistenza omogenea a oxacillina. Nell’impostare un trattamento per infezioni gravi da Stafilococchi sensibili in vitro ad oxacillina è necessario considerare sempre la presenza di un eteroresistenza.

  9. Estudo comparativo da qualidade da água da chuva coletada em telhado com telhas de concreto e em telhado verde para usos não potáveis

    Directory of Open Access Journals (Sweden)

    Celimar Azambuja Teixeira

    Full Text Available Resumo Este artigo apresenta uma comparação da qualidade da água da chuva coletada em telhado inclinado com telhas de concreto (residência 1 e cobertura plana e vegetada (residência 2, indicada como telhado verde. Os objetivos desta investigação foram: (1 analisar a qualidade da água da chuva captada nas duas coberturas, com base nos parâmetros da NBR 15527 (ABNT, 2007 e (2 fazer acompanhamento da qualidade da água armazenada para verificar eficiência e comportamento dos dois telhados. Este estudo foi desenvolvido em Curitiba, PR, onde é obrigatório o aproveitamento da água da chuva em novas construções desde o ano de 2007. A água da chuva captada no telhado com telhas de concreto apresentou menores valores para turbidez e demanda química de oxigênio na maioria dos resultados (oito e sete amostras, respectivamente. O telhado verde contribuiu para a diminuição da acidez natural da água da chuva. Não foram atendidos os parâmetros microbiológicos estabelecidos na NBR 15527 (ABNT, 2007 em nenhuma das amostras coletadas. Apesar de a qualidade da água da chuva não atender todos os parâmetros indicados na NBR 15527 (ABNT, 2007, essa água vem sendo aproveitada nas residências para limpeza de calçadas, irrigação de jardim e descarga em bacias sanitárias, sem indicação de inconvenientes pelos moradores.

  10. Determinantes sociais da saude e o Programa Saude da Familia no municipio de Sao Paulo

    Directory of Open Access Journals (Sweden)

    Tatiana Pluciennik Dowbor

    2013-08-01

    Full Text Available OBJETIVO Analisar a situação do trabalho com determinantes sociais da saúde no âmbito do Programa Saúde da Família. MÉTODOS Estudo de caso com métodos mistos de pesquisa, ancorados em estratégia sequencial explanatória, com 171 gerentes das unidades do Programa Saúde da Família em São Paulo, SP, em 2005/2006. Questionários autopreenchíveis foram aplicados. Entrevistas semiestruturadas e grupos focais foram realizados com amostra intencional de profissionais envolvidos no trabalho com determinantes sociais da saúde. Os dados quantitativos foram analisados por análise descritiva, análise de correspondência múltipla, análise de agrupamento e testes de correlação entre variáveis. Os dados qualitativos foram apurados por análise de conteúdo e a criação de categorias temáticas. RESULTADOS Apesar da concentração de atividades direcionadas ao cuidado com a doença, o Programa Saúde da Família realizou atividades relacionadas à determinação social da saúde, contemplando todas as formas de abordagem da promoção da saúde (biológico, comportamental, psicológico, social e estrutural e os principais determinantes sociais da saúde descritos na literatura. Houve diferença significativa quanto à abrangência dos determinantes trabalhados nas unidades em relação às diferentes regiões do município. Constatou-se fragilidade das iniciativas e a sua desconexão com a estrutura programática do Programa Saúde da Família. CONCLUSÕES A quantidade e variedade de atividades com determinantes sociais da saúde realizadas no Programa Saúde da Família mostram potencial para trabalhar a determinação social da saúde. Mas a fluidez de objetivo e o caráter extraordinário das atividades descritas questionam sua sustentabilidade como parte integral da atual estrutura organizacional do programa.

  11. A ARQUIVÍSTICA COMO DISCIPLINA APLICADA NO CAMPO DA CIÊNCIA DA INFORMAÇÃO

    Directory of Open Access Journals (Sweden)

    Fernanda Ribeiro

    2011-06-01

    Full Text Available Apesar de os arquivos terem origens muito remotas, que se podem confundir com as origens da própria escrita, a Arquivística como disciplina só no século XIX e no quadro do historicismo e do positivismo, se começou a afirmar, numa perspectiva de “ciência auxiliar” da História. Esta perspectiva historicista e custodial adquiriu novos contornos por alturas da viragem do século, graças à afirmação da vertente tecnicista, que se desenvolveu ao longo de todo o século XX, por efeito das condições sociais, económicas e culturais derivadas da revolução tecnológica em curso. Neste texto põe-se em confronto o tradicional paradigma historicista, custodial e tecnicista da Arquivística com um novo paradigma emergente, apelidado de pós-custodial, informacional e científico que entende esta disciplina como um saber aplicado do campo da Ciência da Informação, sendo apresentados os fundamentos epistemológicos, teóricos e metodológicos da abordagem proposta.

  12. Diffuse lung neoplasms. Correlation between high resolution computerized tomography and anatomopathology; Neoplasias pulmonares difusas: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Irion, Klaus L. [Complexo Hospitalar Santa Casa de Porto Alegre, RS (Brazil). Servico de Radiologia do Pavilhao Pereira Filho; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto, SP (Brazil)]. E-mail: edmarchiori@zipmail.com.br

    2002-08-01

    A short comparative evaluation study between high resolution computerized tomography and anatomopathologic findings is presented. The association of these two diagnostic techniques is discussed as a factor to enhance the accuracy of diffuse lung diseases, such as carcinomatous lymphangitis, Kaposi's Sarcoma, lymphomas, hematogenic metastases, bronchiole-alveolar carcinoma and leukemia. (MAC)

  13. A EVOLUÇÃO DA TECNOLOGIA DA INFORMAÇÂO (TI DENTRO DA ADMINISTRAÇÃO

    Directory of Open Access Journals (Sweden)

    Joe Yukinori Katsurayama

    2017-03-01

    Full Text Available Buscamos relacionar a tecnologia e os paradigmas contemporâneos que hoje são de fundamental importância na rede empresarial e como neste contexto cotidiano essa questão é primordial para o desenvolvimento. O fenômeno da globalização mostra o quanto está modernizado a crescente expansão das mídias nas empresas atuais. Diante disto, o objetivo do estudo visa realizar um levantamento bibliográfico sobre a eficácia da Tecnologia da Informação na Administração. Para isto foram levantados estudos sobre a evolução desta tecnologia na base de dados Scielo, Google Acadêmico. Observou- se com o presente estudo que aos poucos as empresas foram se sensibilizando para a importância da informação na gestão de negócios. O conceito de TI engloba software, telecomunicações, automação, recursos multimídia, recursos de organização de dados, entre outros.

  14. Apontamentos sobre a disciplina História da Educação na Universidade da Região da Campanha – Urcamp (1959-2001

    Directory of Open Access Journals (Sweden)

    Regina Quintanilha Azevedo, Clarisse Ismério

    2011-03-01

    Full Text Available Resumo A proposta deste trabalho é fazer um levantamento de dados sobre a disciplina de História da Educação, entre 1959 e 2001, no Curso de Pedagogia, na Universidade da Região da Campanha – URCAMP. Estes apontamentos servirão como contribuição para um futuro mapeamento sobre a disciplina da História da Educação no ensino superior no Brasil. O texto está dividido em três partes: primeiro o perfil da Universidade da Região da Campanha, na segunda parte focalizamos a disciplina de História da Educação no Curso de Pedagogia, nessa Instituição, entre 1959 e 2001, e no terceiro momento o trabalho das professoras da disciplina de História da Educação, atualmente, na URCAMP. Foi realizada uma investigação no arquivo morto da Diretoria de Ingressos e Registros (DIR da URCAMP, nas pastas dos Registros Acadêmicos, no mesmo setor e no setor de Recursos Humanos da Instituição - nas pastas de professores, arquivo digital e no arquivo morto e na Biblioteca. Com um novo olhar na História da Educação foi realizada uma análise das diversas fontes entrecruzadas, tendo a preocupação de que esta apreciação sirva de aporte para novos trabalhos. Palavras-chave: curso de Pedagogia; disciplina História da Educação; formação de professores.   Abstract The proposal of this work is to make a data collecting on disciplines of History of the Education, between 1959 and 2001, in the Course of Pedagogy, in URCAMP (Universidade da Região da Campanha. These notes will serve as contribution for a future mapping on disciplines of History of the Education in superior education in Brazil. The text is divided in three parts: first the profile of the URCAMP, in the second part we focus on disciplines of History of the Education in the Course of Pedagogy, in this Institution, between 1959 - 2001 and at the third moment, the work of the teachers of disciplines of History of the Education, currently, in this University. It was made an inquiry

  15. EEG, transmission computed tomography, and positron emission tomography with fluorodeoxyglucose 18F. Their use in adults with gliomas

    International Nuclear Information System (INIS)

    Newmark, M.E.; Theodore, W.H.; Sato, S.; De La Paz, R.; Patronas, N.; Brooks, R.; Jabbari, B.; Di Chiro, G.

    1983-01-01

    We evaluated the relationship between findings from EEG, transmission computed tomography (CT), and positron emission tomography in 23 adults with gliomas. The cortical metabolic rate was suppressed in patients with and without focal slowing. Focal delta activity was not related to involvement of gray or white matter. Rhythmic delta activity and focal attenuation of background amplitude on EEG, however, were correlated with involvement of the thalamus

  16. Geometric reconstruction methods for electron tomography

    DEFF Research Database (Denmark)

    Alpers, Andreas; Gardner, Richard J.; König, Stefan

    2013-01-01

    Electron tomography is becoming an increasingly important tool in materials science for studying the three-dimensional morphologies and chemical compositions of nanostructures. The image quality obtained by many current algorithms is seriously affected by the problems of missing wedge artefacts...... and discuss several algorithms from the mathematical fields of geometric and discrete tomography. The algorithms incorporate geometric prior knowledge (mainly convexity and homogeneity), which also in principle considerably reduces the number of tilt angles required. Results are discussed...

  17. Mathematics of Photoacoustic and Thermoacoustic Tomography

    KAUST Repository

    Kuchment, Peter; Kunyansky, Leonid

    2011-01-01

    The chapter surveys the mathematical models, problems, and algorithms of the thermoacoustic tomography (TAT) and photoacoustic tomography (PAT). TAT and PAT represent probably the most developed of the several novel “hybrid” methods of medical imaging. These new modalities combine different physical types of waves (electromagnetic and acoustic in case of TAT and PAT) in such a way that the resolution and contrast of the resulting method are much higher than those achievable using only acoustic or electromagnetic measurements.

  18. Non-commutative tomography and signal processing

    International Nuclear Information System (INIS)

    Mendes, R Vilela

    2015-01-01

    Non-commutative tomography is a technique originally developed and extensively used by Professors M A Man’ko and V I Man’ko in quantum mechanics. Because signal processing deals with operators that, in general, do not commute with time, the same technique has a natural extension to this domain. Here, a review is presented of the theory and some applications of non-commutative tomography for time series as well as some new results on signal processing on graphs. (paper)

  19. Max Weber e Martin Heidegger: a centralidade da razão e a perda da liberdade

    Directory of Open Access Journals (Sweden)

    Edilene Maria de Carvalho Leal

    2015-10-01

    Full Text Available A intenção desse artigo é analisar algumas ambivalências da modernidade, com destaque para a que consideramos a principal delas: a centralidade da razão como categoria analítica e como modelo das práticas sociais. Essa proposta é, evidentemente, uma proposta de análise teórica que se dará no âmbito específico da teoria social e da filosofia, principalmente desde interpretações produzidas por Max Weber e Martin Heidegger. Trata-se, em uma primeira instância, da tentativa de discutir criticamente as “autodescrições” que esses pensadores fizeram da modernidade. De um lado, a defesa weberiana da centralidade da razão; de outro, a crítica pós-metafísica heideggeriana dessa centralidade. Desse flagrante desencontro, podemos destacar um possível encontro analítico entre eles, ou seja, a crítica à perda da liberdade no contexto moderno.

  20. Max Weber e Martin Heidegger: a centralidade da razão e a perda da liberdade

    Directory of Open Access Journals (Sweden)

    Edilene Maria de Carvalho Leal

    2015-09-01

    Full Text Available A intenção desse artigo é analisar algumas ambivalências da modernidade, com destaque para a que consideramos a principal delas: a centralidade da razão como categoria analítica e como modelo das práticas sociais. Essa proposta é, evidentemente, uma proposta de análise teórica que se dará no âmbito específico da teoria social e da filosofia, principalmente desde interpretações produzidas por Max Weber e Martin Heidegger. Trata-se, em uma primeira instância, da tentativa de discutir criticamente as “autodescrições” que esses pensadores fizeram da modernidade. De um lado, a defesa weberiana da centralidade da razão; de outro, a crítica pós-metafísica heideggeriana dessa centralidade. Desse flagrante desencontro, podemos destacar um possível encontro analítico entre eles, ou seja, a crítica à perda da liberdade no contexto moderno.

  1. Repercussoes do pet-saude na formacao de estudantes da area da saude

    Directory of Open Access Journals (Sweden)

    Paula Hubner Freitas

    2013-09-01

    Full Text Available OBJETIVO: O estudo teve como objetivo conhecer as repercussões do Programa de Educação pelo Trabalho para a Saúde/PET-Saúde na formação de estudantes da área da saúde. METODOS: Configura-se como exploratório-descritivo, com abordagem qualitativa.Fizeram parte do estudo, vinte estudantes participantes do PET-Saúde. A técnica de coleta de dados foi a entrevista semi-estruturada e o método de análise dos dados empregado, a análise de conteúdo temática. RESULTADOS: Os dados sinalizam que o PET-Saúde configura-se como um programa facilitador para a busca da integralidade e que proporciona articulação teórica-prática entre estudantes, serviço de saúde e comunidade, o que é imprescindível para a reorientação da formação em saúde. CONCLUSÃO: Conclui-se que o desafio centra-se na formação crítico-reflexiva de profissionais da área da saúde, apontando para novos comportamentos e atitudes.

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  4. Positron emission tomography/computed tomography and biomarkers for early treatment response evaluation in metastatic colon cancer

    DEFF Research Database (Denmark)

    Engelmann, Bodil E.; Loft, Annika; Kjær, Andreas

    2014-01-01

    BACKGROUND: Treatment options for metastatic colon cancer (mCC) are widening. We prospectively evaluated serial 2-deoxy-2-[18F]fluoro-d-glucose positron-emission tomography/computed tomography (PET/CT) and measurements of tissue inhibitor of metalloproteinases-1 (TIMP-1), carcinoembryonic antigen...... evaluated by PET/CT before treatment, after one and four treatment series. Morphological and metabolic response was independently assessed according to Response Evaluation Criteria in Solid Tumors and European Organization for Research and Treatment of Cancer PET criteria. Plasma TIMP-1, plasma u...

  5. Spectrum of fluorodeoxyglucose-positron emission tomography/computed tomography and magnetic resonance imaging findings of ovarian tumors.

    Science.gov (United States)

    Kitajima, Kazuhiro; Ueno, Yoshiko; Maeda, Tetsuo; Murakami, Koji; Kaji, Yasushi; Kita, Masato; Suzuki, Kayo; Sugimura, Kazuro

    2011-11-01

    The purpose of this article is to review fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) and magnetic resonance imaging (MRI) findings in a variety of benign, malignant, and borderline malignant ovarian tumors. It is advantageous to become familiar with the wide variety of FDG-PET/CT findings of this entity. Benign ovarian tumors generally have faint uptake, whereas endometriomas, fibromas, and teratomas show mild to moderate uptake. Malignant ovarian tumors generally have intense uptake, whereas tumors with a small solid component often show minimal uptake.

  6. Cone beam computed tomography in Endodontics - a review

    NARCIS (Netherlands)

    Patel, S.; Durack, C.; Abella, F.; Shemesh, H.; Roig, M.; Lemberg, K.

    2015-01-01

    Cone beam computed tomography (CBCT) produces undistorted three-dimensional information of the maxillofacial skeleton, including the teeth and their surrounding tissues with a lower effective radiation dose than computed tomography. The aim of this paper is to: (i) review the current literature on

  7. Papel da vitamina B12 na patogenia da mielose funicular

    Directory of Open Access Journals (Sweden)

    Horacio M. Canelas

    1965-12-01

    Full Text Available Foi estudada a absorção da vitamina B12 radioativa em 29 casos de mielose funicular. O diagnóstico baseou-se na clássica sintomatologia neu- rológica e na presença de acloridria gástrica e eventuais alterações hemato-lógicas. As manifestações neurológicas foram avaliadas de modo semiquan-titativo e correlacionadas com os resultados do teste de excreção urinária da vitamina B12. Não foi verificada correlação significante da absorção da vitamina B12, quer com a sintomatologia nuerológica total, quer com as síndromes periférica e funicular dorsal. Contudo, foi encontrada significante correlação negativa entre a síndrome piramidal e a absorção da vitamina B12. Os resultados são confrontados com o papel desempenhado pela vitamina B12 na síntese das bainhas de mielina e do ácido ribonuclêico, sendo salientada a importância dêste último para a vida das células nervosas e dos longos axônios.

  8. A INFLUÊNCIA DA TECNOLOGIA E DA INTERNET NO MARKETING

    Directory of Open Access Journals (Sweden)

    Lúcia Cristina Vargas Machado

    2014-09-01

    Full Text Available O dinamismo do mundo globalizado vem exigindo grandes mudanças das organizações, sejam para aquelas que produzem bens tangíveis, sejam para as prestadoras de serviços. E dentro da observância das mudanças, pode-se considerar as revoluções vividas pela humanidade, considerando aquela que mais mudou o cenário mercadológico pela primeira vez que foi 1ª revolução industrial e, a outra, a revolução da informação. Neste contexto, o objetivo deste trabalho é demonstrar através da revisão de literatura, a significativa e importante transformação da informação para a área de marketing das organizações. A revolução da informação, tendo como suas precursoras e legítimas aliadas a tecnologia e a internet, respectivamente, fez com que surgisse um novo tipo de marketing: o marketing digital. Com este novo tipo de marketing, as organizações que estiverem mais presentes na internet, poderão obter uma maior vantagem competitiva e como consequência uma maior lucratividade

  9. The use of computed tomography in brain damage testing

    International Nuclear Information System (INIS)

    De Villiers, J.F.K.

    1980-01-01

    The article deals with the diagnosis of brain damage by the use of computerized tomography - especially referring to the injuries of boxers. Three conditions may be evaluated with computerized tomography: i) fenestration of the septum pellucidum; ii) cortical atrophy; and, iii) cerebral atrophy. It also appears that computerized tomography has a place in the evaluation of injuries sustained in the ring, as well as the detection of accelerated ageing of the brain or atrophy

  10. DIAGNOSTIC ROLE OF FLUORINE-18 (18F) FLUORODEOXYGLUCOSE POSITRON EMISSION TOMOGRAPHY COMPUTED TOMOGRAPHY IN DETECTING RECURRENT DISEASE IN PATIENTS WITH COLORECTAL CANCER AND ELEVATED CARCINOEMBRYONIC ANTIGEN.

    Science.gov (United States)

    Matovina, Emil; Mihailović, Jasna; Nikoletić, Katarina; Srbovan, Dolores

    2015-01-01

    Early detection of recurrence is an important factor for long term survival of patients with colorectal cancer. Measurement of serum levels of carcinoembryonic antigen has been commonly used in the postoperative surveillance of colorectal cancer. The purpose of this study was to evaluate the ability of positron emission tomography-computed tomography to detect pathological substrate of elevated serum carcinoembryonic antigen in patients with colorectal cancer. The patients with colorectal cancer who underwent curative surgical resection and/ or chemotherapy, who were found in our database, were analyzed retrospectively. Forty-eight 18F-fluorodeoxyglucose positron emission tomography-computed tomography studies including 45 patients (14 women, 31 men; mean age: 62.93 years) with elevated serum, carcinoembryonic antigen levels, which had been performed between January 2011 and January 2014, were evaluated. Serum levels of carcinoembryonic antigen were measured within 3 months after positron emission tomography-computed tomography examination. Final diagnosis of recurrence was made by histopathological findings, radiology studies or clinical follow-up. Recurrences were diagnosed in 37 patients, the prevalence being 77.1%. Liver metastases were found in 18 patients, abdominal, pelvic and/or mediastinal lymph nodes were positive in 19 patients, 11 patients had loco regional recurrences and 4 patients had pulmonary metastasis, and bone metastases were found in one patient. One patient was diagnosed with metastasis in scar tissue. The overall sensitivity and specificity of positron emission tomography-computed tomography was 90.24% and 71.42%, respectively. The positive and negative predictive values were 94.87% and 55.56%, respectively. 18F-fluorodeoxyglucose positron emission tomography-computed tomography is a powerful tool that could be used in determining colorectal cancer recurrence in patients with elevated carcinoembryonic antigen levels and could have an

  11. Coded aperture tomography revisited

    International Nuclear Information System (INIS)

    Bizais, Y.; Rowe, R.W.; Zubal, I.G.; Bennett, G.W.; Brill, A.B.

    1983-01-01

    Coded aperture (CA) Tomography never achieved wide spread use in Nuclear Medicine, except for the degenerate case of Seven Pinhole tomagraphy (7PHT). However it enjoys several attractive features (high sensitivity and tomographic ability with a statis detector). On the other hand, resolution is usually poor especially along the depth axis and the reconstructed volume is rather limited. Arguments are presented justifying the position that CA tomography can be useful for imaging time-varying 3D structures, if its major drawbacks (poor longitudinal resolution and difficulty in quantification) are overcome. Poor results obtained with 7PHT can be explained by both a very limited angular range sampled and a crude modelling of the image formation process. Therefore improvements can be expected by the use of a dual-detector system, along with a better understanding of its sampling properties and the use of more powerful reconstruction algorithms. Non overlapping multipinhole plates, because they do not involve a decoding procedure, should be considered first for practical applications. Use of real CA should be considered for cases in which non overlapping multipinhole plates do not lead to satisfactory solutions. We have been and currently are carrying out theoretical and experimental works, in order to define the factors which limit CA imaging and to propose satisfactory solutions for Dynamic Emission Tomography

  12. Tumores intracranianos em pacientes encaminhados para estudos por tomografia de coerência óptica como portadores de glaucoma sem hipertensão ocular: relato de dois casos Intracranial tumors in patients referred for optical coherence tomography examination as glaucoma suspects: case report

    Directory of Open Access Journals (Sweden)

    Laurentino Biccas Neto

    2009-10-01

    Full Text Available A tomografia de coerência óptica (OCT tem se mostrado muito útil na avaliação de pacientes com glaucoma. São relatadas duas pacientes referidas com a suspeita de glaucoma sem hipertensão para avaliação por tomografia de coerência óptica que, na verdade, eram portadoras de tumores intracranianos - um cordoma de clivo no primeiro caso e um craniofaringeoma no segundo. Os achados à tomografia de coerência óptica - diminuição difusa da espessura da camada de fibras nervosas circumdiscais desproporcionalmente acentuada nos setores nasal e temporal - levantaram a suspeita de acometimento na região do quiasma e permitiram o diagnóstico destes importantes tumores intracranianos.Optical coherence tomography (OCT has proved to be a very valuable tool in the assessment of patients with glaucoma. In this report, intracranial tumors were discovered in two glaucoma suspects referred for diagnostic confirmation by OCT - a clivus chordoma and a craniopharyngeoma. Optical coherence tomography findings - marked asymmetrical diffuse attenuation of the peripapillary nerve fiber layer in nasal and temporal sectors - raised concerns about lesions in chiasmatic region and permitted the timely diagnosis of these intraocular tumors.

  13. Inverse scattering theory foundations of tomography with diffracting wavefields

    International Nuclear Information System (INIS)

    Devaney, A.J.

    1987-01-01

    The underlying mathematical models employed in reflection and transmission computed tomography using diffracting wavefields (called diffraction tomography) are reviewed and shown to have a rigorous basis in inverse scattering theory. In transmission diffraction tomography the underlying wave model is shown to be the Rytov approximation to the complex phase of the wavefield transmitted by the object being probed while in reflection diffraction tomography the underlying wave model is shown to be the Born approximation to the backscattered wavefield from the object. In both cases the goal of the reconstruction process is the determination of the objects's complex index of refraction as a function of position r/sup →/ and, possibly, the frequency ω of the probing wavefield. By use of these approximations the reconstruction problem for both transmission and reflection diffraction tomography can be cast into the simple and elegant form of linearized inverse scattering theory. Linearized inverse scattering theory is shown to lead directly to generalized projection-slice theorems for both reflection and transmission diffraction tomography that provide a simple mathematical relationship between the object's complex index of refraction (the unknown) and the data (the complex phase of the transmitted wave or the complex amplitude of the reflected wave). The conventional projection-slice theorem of X-ray CT is shown to result from the generalized projection-slice theorem for transmission diffraction tomography in the limit of vanishing wavelength (in the absence of wave effects). Fourier based and back-projection type reconstruction algorithms are shown to be directly derivable from the generalized projection-slice theorems

  14. Pessoal ocupado e jornada de trabalho: uma releitura da evolução da produtividade no Brasil

    Directory of Open Access Journals (Sweden)

    Fernando de Holanda Barbosa Filho

    2014-06-01

    Full Text Available Esse artigo recalcula a evolução da produtividade do trabalho e da produtividade total dos Fatores (PTF no Brasil entre os anos de 1982 e 2012 usando uma série de horas trabalhadas em vez da série de pessoal ocupado. Para tanto, utilizamos dados da PNAD e da PME para construir uma série mensal de horas trabalhadas que compatibilizasse as mudanças metodológicas da PNAD e da PME. A comparação da série de horas trabalhadas com a de pessoal ocupado revela a redução da jornada de trabalho no Brasil, fenômeno consistente em todo o período de análise e que impacta a produtividade. Com isso, a utilização de uma série de horas trabalhadas possibilita uma releitura da evolução da produtividade nas últimas três décadas no Brasil. Em particular, mostramos que a perda da produtividade do trabalho (-0,6% a.a ocorrida entre os anos de 1982 e 1992 é explicada pela redução da jornada de trabalho média (-0,7% da economia brasileira. Os resultados indicam que, no período 1982-2012, tanto a produtividade do trabalho (35,8% quanto a PTF (16,3% apresentaram uma elevação superior à sugerida por boa parte da literatura sobre o tema baseada em séries de pessoal ocupado.

  15. Positron emission tomography

    International Nuclear Information System (INIS)

    Pavuk, M.

    2003-12-01

    The aim of this project is to provide a simple summary of new trends in positron emission tomography and its basic physical principles. It provides thereby compendious introduction of the trends of the present development in diagnostics using PET systems. A review of available literature was performed. (author)

  16. Holography and tomography

    Energy Technology Data Exchange (ETDEWEB)

    Howells, M. [Lawrence Berkeley National Lab., CA (United States)

    1997-02-01

    This session includes a collection of outlines of pertinent information, diagrams, graphs, electron micrographs, and color photographs pertaining to historical aspects and recent advances in the development of X-ray Gabor Holography. Many of the photographs feature or pertain to instrumentation used in holography, tomography, and cryo-holography.

  17. Holography and tomography

    International Nuclear Information System (INIS)

    Howells, M.

    1997-01-01

    This session includes a collection of outlines of pertinent information, diagrams, graphs, electron micrographs, and color photographs pertaining to historical aspects and recent advances in the development of X-ray Gabor Holography. Many of the photographs feature or pertain to instrumentation used in holography, tomography, and cryo-holography

  18. GERONTOLOGIA: ESTADO DA ARTE

    Directory of Open Access Journals (Sweden)

    Vera M.A.Tordino Brandão

    2010-02-01

    Full Text Available O Programa de Gerontologia da PUC desenvolve pesquisas focando o ser na perspectiva do envelhecimento. As atividades são interdisciplinares e reúnem docentes, alunos e ex-alunos. Nesta mesa redonda apresentamos um panorama sobre estes estudos. Na área da educação e comunicação o foco está centrado na longevidade e na preparação e representação social da velhice. São ressaltadas como temáticas: a formação continuada de profissionais e pesquisadores; o significado da religiosidade/espiritualidade ao longo da trajetória, e sua repercussão na qualidade de vida do idoso; os programas sócio-educacionais para idosos e concepções sobre educação; o monitoramento da mídia na cobertura da crescente longevidade e seus impactos. Em identidade e modos de morar reflete-se sobre soluções planejadas e sua adequação para a inclusão do envelhecimento populacional como questão fundamental, que implica a elaboração de novas políticas, investigações e, especialmente, apresenta-se como questão a ser analisada, refletida e vivenciada pela sociedade em geral. Quanto à saúde, o Programa desenvolve várias pesquisas numa abordagem interdisciplinar tendo como objetos de estudo: a terapia assistida com animais direcionada a idosos com diagnóstico de Alzheimer; o acompanhamento terapêutico e o atendimento psicoterapêutico em grupo, a aplicação da técnica de Calatonia em idosos moradores de ILPI, além da investigação sobre impasses clínicos no idoso frágil. Palavras-chave: gerontologia, longevidade, envelhecimento

  19. Metabolomics of Breast Cancer Using High-Resolution Magic Angle Spinning Magnetic Resonance Spectroscopy: Correlations with 18F-FDG Positron Emission Tomography-Computed Tomography, Dynamic Contrast-Enhanced and Diffusion-Weighted Imaging MRI.

    Science.gov (United States)

    Yoon, Haesung; Yoon, Dahye; Yun, Mijin; Choi, Ji Soo; Park, Vivian Youngjean; Kim, Eun-Kyung; Jeong, Joon; Koo, Ja Seung; Yoon, Jung Hyun; Moon, Hee Jung; Kim, Suhkmann; Kim, Min Jung

    2016-01-01

    Our goal in this study was to find correlations between breast cancer metabolites and conventional quantitative imaging parameters using high-resolution magic angle spinning (HR-MAS) magnetic resonance spectroscopy (MRS) and to find breast cancer subgroups that show high correlations between metabolites and imaging parameters. Between August 2010 and December 2013, we included 53 female patients (mean age 49.6 years; age range 32-75 years) with a total of 53 breast lesions assessed by the Breast Imaging Reporting and Data System. They were enrolled under the following criteria: breast lesions larger than 1 cm in diameter which 1) were suspicious for malignancy on mammography or ultrasound (US), 2) were pathologically confirmed to be breast cancer with US-guided core-needle biopsy (CNB) 3) underwent 3 Tesla MRI with dynamic contrast-enhanced (DCE) and diffusion-weighted imaging (DWI) and positron emission tomography-computed tomography (PET-CT), and 4) had an attainable immunohistochemistry profile from CNB. We acquired spectral data by HR-MAS MRS with CNB specimens and expressed the data as relative metabolite concentrations. We compared the metabolites with the signal enhancement ratio (SER), maximum standardized FDG uptake value (SUV max), apparent diffusion coefficient (ADC), and histopathologic prognostic factors for correlation. We calculated Spearman correlations and performed a partial least squares-discriminant analysis (PLS-DA) to further classify patient groups into subgroups to find correlation differences between HR-MAS spectroscopic values and conventional imaging parameters. In a multivariate analysis, the PLS-DA models built with HR-MAS MRS metabolic profiles showed visible discrimination between high and low SER, SUV, and ADC. In luminal subtype breast cancer, compared to all cases, high SER, ADV, and SUV were more closely clustered by visual assessment. Multiple metabolites were correlated with SER and SUV in all cases. Multiple metabolites showed

  20. Metabolomics of Breast Cancer Using High-Resolution Magic Angle Spinning Magnetic Resonance Spectroscopy: Correlations with 18F-FDG Positron Emission Tomography-Computed Tomography, Dynamic Contrast-Enhanced and Diffusion-Weighted Imaging MRI.

    Directory of Open Access Journals (Sweden)

    Haesung Yoon

    Full Text Available Our goal in this study was to find correlations between breast cancer metabolites and conventional quantitative imaging parameters using high-resolution magic angle spinning (HR-MAS magnetic resonance spectroscopy (MRS and to find breast cancer subgroups that show high correlations between metabolites and imaging parameters.Between August 2010 and December 2013, we included 53 female patients (mean age 49.6 years; age range 32-75 years with a total of 53 breast lesions assessed by the Breast Imaging Reporting and Data System. They were enrolled under the following criteria: breast lesions larger than 1 cm in diameter which 1 were suspicious for malignancy on mammography or ultrasound (US, 2 were pathologically confirmed to be breast cancer with US-guided core-needle biopsy (CNB 3 underwent 3 Tesla MRI with dynamic contrast-enhanced (DCE and diffusion-weighted imaging (DWI and positron emission tomography-computed tomography (PET-CT, and 4 had an attainable immunohistochemistry profile from CNB. We acquired spectral data by HR-MAS MRS with CNB specimens and expressed the data as relative metabolite concentrations. We compared the metabolites with the signal enhancement ratio (SER, maximum standardized FDG uptake value (SUV max, apparent diffusion coefficient (ADC, and histopathologic prognostic factors for correlation. We calculated Spearman correlations and performed a partial least squares-discriminant analysis (PLS-DA to further classify patient groups into subgroups to find correlation differences between HR-MAS spectroscopic values and conventional imaging parameters.In a multivariate analysis, the PLS-DA models built with HR-MAS MRS metabolic profiles showed visible discrimination between high and low SER, SUV, and ADC. In luminal subtype breast cancer, compared to all cases, high SER, ADV, and SUV were more closely clustered by visual assessment. Multiple metabolites were correlated with SER and SUV in all cases. Multiple metabolites