WorldWideScience

Sample records for tomographie optique diffusive

  1. Contribution de la tomographie par coherence optique au diagnostic ...

    African Journals Online (AJOL)

    Contribution de la tomographie par coherence optique au diagnostic de la neuropathie optique toxique. C.O.A. Abouki, S Alamou, C.R.A. Assavedo, L Odoulami-Yehouessi, I Sounouvou, S Hounnou-Tchabi ...

  2. In Vivo Diffuse Optical Tomography and Fluorescence Molecular Tomography

    Directory of Open Access Journals (Sweden)

    Mingze Li

    2010-01-01

    Full Text Available Diffuse optical tomography (DOT and fluorescence molecular tomography (FMT are two attractive imaging techniques for in vivo physiological and psychological research. They have distinct advantages such as non-invasiveness, non-ionizing radiation, high sensitivity and longitudinal monitoring. This paper reviews the key components of DOT and FMT. Light propagation model, mathematical reconstruction algorithm, imaging instrumentation and medical applications are included. Future challenges and perspective on optical tomography are discussed.

  3. Diffuse nesidioblastosis diagnosed on a Ga-68 DOTATATE positron emission tomography/computerized tomography

    International Nuclear Information System (INIS)

    Arun, Sasikumar; Mittal, Bhagwant Rai; Shukla, Jaya; Bhattacharya, Anish; Kumar, Praveen

    2013-01-01

    The authors describe a 50 days old pre-term infant with persistent hyperinsulinemic hypoglycemia of infancy in whom 68 Ga DOTATATE positron emission tomography/computerized tomography scan showed diffusely increased tracer uptake in the entire pancreas with no abnormal tracer uptake anywhere else in the body, suggestive of a diffuse variant of nesidioblastosis. (author)

  4. Massively parallel diffuse optical tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sandusky, John V.; Pitts, Todd A.

    2017-09-05

    Diffuse optical tomography systems and methods are described herein. In a general embodiment, the diffuse optical tomography system comprises a plurality of sensor heads, the plurality of sensor heads comprising respective optical emitter systems and respective sensor systems. A sensor head in the plurality of sensors heads is caused to act as an illuminator, such that its optical emitter system transmits a transillumination beam towards a portion of a sample. Other sensor heads in the plurality of sensor heads act as observers, detecting portions of the transillumination beam that radiate from the sample in the fields of view of the respective sensory systems of the other sensor heads. Thus, sensor heads in the plurality of sensors heads generate sensor data in parallel.

  5. Diffuse abnormalities of the trachea: computed tomography findings

    International Nuclear Information System (INIS)

    Marchiori, Edson; Araujo Neto, Cesar de

    2008-01-01

    The aim of this pictorial essay was to present the main computed tomography findings seen in diffuse diseases of the trachea. The diseases studied included amyloidosis, tracheobronchopathia osteochondroplastica, tracheobronchomegaly, laryngotracheobronchial papillomatosis, lymphoma, neurofibromatosis, relapsing polychondritis, Wegener's granulomatosis, tuberculosis, paracoccidioidomycosis, and tracheobronchomalacia. The most common computed tomography finding was thickening of the walls of the trachea, with or without nodules, parietal calcifications, or involvement of the posterior wall. Although computed tomography allows the detection and characterization of diseases of the central airways, and the correlation with clinical data reduces the diagnostic possibilities, bronchoscopy with biopsy remains the most useful procedure for the diagnosis of diffuse lesions of the trachea. (author)

  6. On uniqueness in diffuse optical tomography

    International Nuclear Information System (INIS)

    Harrach, Bastian

    2009-01-01

    A prominent result of Arridge and Lionheart (1998 Opt. Lett. 23 882–4) demonstrates that it is in general not possible to simultaneously recover both the diffusion (aka scattering) and the absorption coefficient in steady-state (dc) diffusion-based optical tomography. In this work we show that it suffices to restrict ourselves to piecewise constant diffusion and piecewise analytic absorption coefficients to regain uniqueness. Under this condition both parameters can simultaneously be determined from complete measurement data on an arbitrarily small part of the boundary

  7. Edge-promoting reconstruction of absorption and diffusivity in optical tomography

    DEFF Research Database (Denmark)

    Hannukainen, A.; Harhanen, Lauri Oskari; Hyvönen, N.

    2015-01-01

    In optical tomography a physical body is illuminated with near-infrared light and the resulting outward photon flux is measured at the object boundary. The goal is to reconstruct internal optical properties of the body, such as absorption and diffusivity. In this work, it is assumed that the imaged...... measurement noise model. The method is based on iteratively combining a lagged diffusivity step and a linearization of the measurement model of diffuse optical tomography with priorconditioned LSQR. The performance of the reconstruction technique is tested via three-dimensional numerical experiments...

  8. Diffusion tensor optical coherence tomography

    Science.gov (United States)

    Marks, Daniel L.; Blackmon, Richard L.; Oldenburg, Amy L.

    2018-01-01

    In situ measurements of diffusive particle transport provide insight into tissue architecture, drug delivery, and cellular function. Analogous to diffusion-tensor magnetic resonance imaging (DT-MRI), where the anisotropic diffusion of water molecules is mapped on the millimeter scale to elucidate the fibrous structure of tissue, here we propose diffusion-tensor optical coherence tomography (DT-OCT) for measuring directional diffusivity and flow of optically scattering particles within tissue. Because DT-OCT is sensitive to the sub-resolution motion of Brownian particles as they are constrained by tissue macromolecules, it has the potential to quantify nanoporous anisotropic tissue structure at micrometer resolution as relevant to extracellular matrices, neurons, and capillaries. Here we derive the principles of DT-OCT, relating the detected optical signal from a minimum of six probe beams with the six unique diffusion tensor and three flow vector components. The optimal geometry of the probe beams is determined given a finite numerical aperture, and a high-speed hardware implementation is proposed. Finally, Monte Carlo simulations are employed to assess the ability of the proposed DT-OCT system to quantify anisotropic diffusion of nanoparticles in a collagen matrix, an extracellular constituent that is known to become highly aligned during tumor development.

  9. Edge-promoting reconstruction of absorption and diffusivity in optical tomography

    International Nuclear Information System (INIS)

    Hannukainen, A; Hyvönen, N; Majander, H; Harhanen, L

    2016-01-01

    In optical tomography a physical body is illuminated with near-infrared light and the resulting outward photon flux is measured at the object boundary. The goal is to reconstruct internal optical properties of the body, such as absorption and diffusivity. In this work, it is assumed that the imaged object is composed of an approximately homogeneous background with clearly distinguishable embedded inhomogeneities. An algorithm for finding the maximum a posteriori estimate for the absorption and diffusion coefficients is introduced assuming an edge-preferring prior and an additive Gaussian measurement noise model. The method is based on iteratively combining a lagged diffusivity step and a linearization of the measurement model of diffuse optical tomography with priorconditioned LSQR. The performance of the reconstruction technique is tested via three-dimensional numerical experiments with simulated data. (paper)

  10. Optique quantique en environnement solide

    OpenAIRE

    Auffèves , Alexia

    2014-01-01

    Mon objectif premier a été de revisiter l’optique quantique (initialement explorée avec des atomes et des cavités naturels) avec des atomes et des cavités artificiels, tels que des boîtes quantiques semi-conductrices, ou des qubits en électrodynamique quantique des circuits. Contrairement aux systèmes de physique atomique, les atomes et les cavités de la matière condensée sont couplés à des environnements natifs, qui conduisent à des divergences fon- damentales par rapport à l’...

  11. Near-Infrared Diffuse Optical Tomography

    Directory of Open Access Journals (Sweden)

    A. H. Hielscher

    2002-01-01

    Full Text Available Diffuse optical tomography (DOT is emerging as a viable new biomedical imaging modality. Using near-infrared (NIR light, this technique probes absorption as well as scattering properties of biological tissues. First commercial instruments are now available that allow users to obtain cross-sectional and volumetric views of various body parts. Currently, the main applications are brain, breast, limb, joint, and fluorescence/bioluminescence imaging. Although the spatial resolution is limited when compared with other imaging modalities, such as magnetic resonance imaging (MRI or X-ray computerized tomography (CT, DOT provides access to a variety of physiological parameters that otherwise are not accessible, including sub-second imaging of hemodynamics and other fast-changing processes. Furthermore, DOT can be realized in compact, portable instrumentation that allows for bedside monitoring at relatively low cost. In this paper, we present an overview of current state-of-the -art technology, including hardware and image-reconstruction algorithms, and focus on applications in brain and joint imaging. In addition, we present recent results of work on optical tomographic imaging in small animals.

  12. Analysis of radiation fields in tomography on diffusion gaseous sound

    International Nuclear Information System (INIS)

    Bekman, I.N.

    1999-01-01

    Perspectives of application of equilibrium and stationary variants of diffusion tomography with radioactive gaseous sounds for spatial reconstruction of heterogeneous media in materials technology were considered. The basic attention were allocated to creation of simple algorithms of detection of sound accumulation on the background of monotonically varying concentration field. Algorithms of transformation of two-dimensional radiation field in three-dimensional distribution of radiation sources were suggested. The methods of analytical elongation of concentration field permitting separation of regional anomalies on the background of local ones and vice verse were discussed. It was shown that both equilibrium and stationary variants of diffusion tomography detect the heterogeneity of testing material, provide reduction of spatial distribution of elements of its structure and give an estimation of relative degree of defectiveness

  13. Computerized tomography in diffuse diseases of the liver. Pt. 2

    International Nuclear Information System (INIS)

    Helmberger, H.; Vogel, U.; Bautz, W.

    1993-01-01

    Computerized tomography is a first-line method of imaging to confirm diffuse disorders of the liver suggested by preliminary clinical and biochemical findings. If the disease is caused by an obstructed vessel, this is reliably detected. For most types of thesaurismosis as well as hepatic steatosis and cirrhosis of the liver approaches to quantitative determinations of the spread of disease have been described in theory but so far failed to show great merits in practice. The transition from hepatic fibrosis to cirrhosis as the final developmental stage common to all those disorders has typical features on computerized tomography. This explains why the use of this method in diffuse hepatic disease offers particular advantages as regards the detection of complications occurring at an advanced stage ot the diagnosis of changes developing into malignancies. (orig.) [de

  14. Analysis and optimization of a diffuse photon optical tomography of turbid media

    International Nuclear Information System (INIS)

    Everitt, David L.; Wei, Sung-po; Zhu, X. D.

    2000-01-01

    In a numerical study, we investigate a diffuse-photon computed tomography of a turbid medium. Using a perturbation approach, we relate through a matrix K a bulk heterogeneous distribution of the optical absorption coefficient μ a that characterizes the heterogeneity in an otherwise homogeneous turbid medium to the diffuse photon flux that emerges from its surface. By studying the condition number (N C ) of the matrix K as a function of illumination-detection schemes and choices of reconstruction grids, we explore strategies that optimize the fidelity and spatial resolution of the computed tomography. (c) 2000 The American Physical Society

  15. Fourier diffraction theorem for diffusion-based thermal tomography

    International Nuclear Information System (INIS)

    Baddour, Natalie

    2006-01-01

    There has been much recent interest in thermal imaging as a method of non-destructive testing and for non-invasive medical imaging. The basic idea of applying heat or cold to an area and observing the resulting temperature change with an infrared camera has led to the development of rapid and relatively inexpensive inspection systems. However, the main drawback to date has been that such an approach provides mainly qualitative results. In order to advance the quantitative results that are possible via thermal imaging, there is interest in applying techniques and algorithms from conventional tomography. Many tomography algorithms are based on the Fourier diffraction theorem, which is inapplicable to thermal imaging without suitable modification to account for the attenuative nature of thermal waves. In this paper, the Fourier diffraction theorem for thermal tomography is derived and discussed. The intent is for this thermal-diffusion based Fourier diffraction theorem to form the basis of tomographic reconstruction algorithms for quantitative thermal imaging

  16. New imaging algorithm in diffusion tomography

    Science.gov (United States)

    Klibanov, Michael V.; Lucas, Thomas R.; Frank, Robert M.

    1997-08-01

    A novel imaging algorithm for diffusion/optical tomography is presented for the case of the time dependent diffusion equation. Numerical tests are conducted for ranges of parameters realistic for applications to an early breast cancer diagnosis using ultrafast laser pulses. This is a perturbation-like method which works for both homogeneous a heterogeneous background media. Its main innovation lies in a new approach for a novel linearized problem (LP). Such an LP is derived and reduced to a boundary value problem for a coupled system of elliptic partial differential equations. As is well known, the solution of such a system amounts to the factorization of well conditioned, sparse matrices with few non-zero entries clustered along the diagonal, which can be done very rapidly. Thus, the main advantages of this technique are that it is fast and accurate. The authors call this approach the elliptic systems method (ESM). The ESM can be extended for other data collection schemes.

  17. Diffuse fluorescence tomography of exo- and endogenously labeled tumors

    Science.gov (United States)

    Balalaeva, Irina V.; Turchin, Ilya V.; Orlova, Anna G.; Plekhanov, Vladimir I.; Shirmanova, Marina V.; Kleshnin, Michail S.; Fiks, Ilya I.; Zagainova, Elena V.; Kamensky, Vladislav A.

    2007-06-01

    Strong light scattering and absorption limit observation of the internal structure of biological tissue. Only special tools for turbid media imaging, such as optical diffuse tomography, enable noninvasive investigation of the internal biological tissues, including visualization and intravital monitoring of deep tumors. In this work the preliminary results of diffuse fluorescence tomography (DFT) of small animals are presented. Usage of exogenous fluorophores, targeted specifically at tumor cells, and fluorescent proteins expressed endogenously can significantly increase the contrast of obtained images. Fluorescent compounds of different nature, such as sulphonated aluminium phthalocyanine (Photosens), red fluorescing proteins and CdTe/CdSe-core/shell nanocrystals (quantum dots) were applied. We tested diffuse fluorescence tomography method at model media, in post mortem and in vivo experiments. The animal was scanned in transilluminative configuration by low-frequency modulated light (1 kHz) from Nd:YAG laser with second harmonic generation at wavelength of 532 nm or semiconductor laser at wavelength of 655 nm. Quantum dots or protein DsRed2 in glass capsules (inner diameter 2-3 mm) were placed post mortem inside the esophagus of 7-day-old hairless rats to simulate marked tumors. Photosens was injected intravenously to linear mice with metastazing Lewis lung carcinoma. The reconstruction algorithm, based on Algebraic Reconstruction Technique, was created and tested numerically in model experiments. High contrast images of tumor simulating capsules with DsRed2 concentrations about 10 -6 M and quantum dots about 5x10 -11 M have been obtained. Organ distribution of Photosens and its accumulation in tumors and surrounding tissues of animals has been examined. We have conducted the monitoring of tumors, exogenously labeled by photosensitizer. This work demonstrates potential capabilities of DFT method for intravital detection and monitoring of deep fluorescent

  18. Fibre optique à la maison en Pays de Gex et de Bellegarde

    CERN Multimedia

    CERN. Geneva; Goy, Jean Paul

    2010-01-01

    Le Syndicat Intercommunal d’Electricité de l’Ain(SIEA) déploie un réseau FTTH (Fiber To The Home) de fibres optiques dans le département de l’Ain vers l’ensemble des habitations. Le déploiement sur la zone pilote du Pays de Gex et du Bassin Bellegardien arrive dans la phase terminale vers les habitations. Le SIEA présentera ses activités, l’état du développement du réseau, les implications d’une connexion fibre optique et les procédures d’abonnement. La présentation sera donnée en Français. -------------------------------------------------------------------------------------------------------------------------------Public conference "Optical fiber To The Home in Pays de Gex et de Bellegarde" Michel Chanel et Jean Paul Goy (SIEA) Wednesday, 19th May at 11.30 hrs., Counc...

  19. Small-Animal Imaging Using Diffuse Fluorescence Tomography.

    Science.gov (United States)

    Davis, Scott C; Tichauer, Kenneth M

    2016-01-01

    Diffuse fluorescence tomography (DFT) has been developed to image the spatial distribution of fluorescence-tagged tracers in living tissue. This capability facilitates the recovery of any number of functional parameters, including enzymatic activity, receptor density, blood flow, and gene expression. However, deploying DFT effectively is complex and often requires years of know-how, especially for newer mutlimodal systems that combine DFT with conventional imaging systems. In this chapter, we step through the process of using MRI-DFT imaging of a receptor-targeted tracer in small animals.

  20. Les métamatériaux, des micro-ondes à l'optique : théorie et applications

    Science.gov (United States)

    Kante, B.

    2010-04-01

    Cet article constitue une contribution originale et importante à la compréhension à la fois théorique et expérimentale des métamatériaux en micro-ondes et en infrarouge. Nous avons réalisé et caractérisé sur silicium des nano-structures metallo-diélectriques, briques de base des métamatériaux infrarouge et optique. Des caractérisations optiques exhaustives ont été réalisées pour la première fois sur ces structures en amplitude et en phase par interférométrie. Des topologies plus simples de métamatériaux d’un point de vue technologique et des performances optiques ont été introduites, et leur potentiel démontré dans la réalisation de fonctions aussi complexes que la réfraction négative, le couplage de mode plasmoniques, les nano senseurs pour la biologie et l’invisibilité électromagnétique en infrarouge. Les transformations d’espace, et le nouveau paradigme qu’elles offrent à l’optique, rendant possible une ingénierie de l’espace pour les photons ainsi que leur implémentation par métamatériaux ont été présentés par la première démonstration expérimentale d’une cape d’invisibilité non magnétique.

  1. Consistency of ocular coherence tomography fast macular thickness mapping in diabetic diffuse macular edema

    International Nuclear Information System (INIS)

    Saraiva, Fabio Petersen; Costa, Patricia Grativol; Inomata, Daniela Lumi; Melo, Carlos Sergio Nascimento; Helal Junior, John; Nakashima, Yoshitaka

    2007-01-01

    Objectives: To investigate optical coherence tomography consistency on foveal thickness, foveal volume, and macular volume measurements in patients with and without diffuse diabetic macular edema. Introduction: Optical coherence tomography represents an objective technique that provides cross-sectional tomographs of retinal structure in vivo. However, it is expected that poor fixation ability, as seen in diabetic macular edema, could alter its results. Several authors have discussed the reproducibility of optical coherence tomography, but only a few have addressed the topic with respect to diabetic maculopathy. Methods: The study recruited diabetic patients without clinically evident retinopathy (control group) and with diffuse macular edema (case group). Only one eye of each patient was evaluated. Five consecutive fast macular scans were taken using Ocular Coherence Tomography 3; the 6 mm macular map was chosen. The consistency in measurements of foveal thickness, foveal volume, and total macular volume for both groups was evaluated using the Pearson's coefficient of variation. The T-test for independent samples was used in order to compare measurements of both groups. Results: Each group consisted of 20 patients. All measurements had a coefficient of variation less than 10%. The most consistent parameter for both groups was the total macular volume. Discussion: Consistency in measurement is a mainstay of any test. A test is unreliable if its measurements can not be correctly repeated. We found a good index of consistency, even considering patients with an unstable gaze. Conclusions: Optical coherence tomography is a consistent method for diabetic subjects with diffuse macular edema. (author)

  2. Consistency of ocular coherence tomography fast macular thickness mapping in diabetic diffuse macular edema

    Energy Technology Data Exchange (ETDEWEB)

    Saraiva, Fabio Petersen; Costa, Patricia Grativol; Inomata, Daniela Lumi; Melo, Carlos Sergio Nascimento; Helal Junior, John; Nakashima, Yoshitaka [Universidade de Sao Paulo (USP), SP (Brazil). Hospital das Clinicas. Dept. de Oftalmologia]. E-mail: fabiopetersen@yahoo.com.br

    2007-07-01

    Objectives: To investigate optical coherence tomography consistency on foveal thickness, foveal volume, and macular volume measurements in patients with and without diffuse diabetic macular edema. Introduction: Optical coherence tomography represents an objective technique that provides cross-sectional tomographs of retinal structure in vivo. However, it is expected that poor fixation ability, as seen in diabetic macular edema, could alter its results. Several authors have discussed the reproducibility of optical coherence tomography, but only a few have addressed the topic with respect to diabetic maculopathy. Methods: The study recruited diabetic patients without clinically evident retinopathy (control group) and with diffuse macular edema (case group). Only one eye of each patient was evaluated. Five consecutive fast macular scans were taken using Ocular Coherence Tomography 3; the 6 mm macular map was chosen. The consistency in measurements of foveal thickness, foveal volume, and total macular volume for both groups was evaluated using the Pearson's coefficient of variation. The T-test for independent samples was used in order to compare measurements of both groups. Results: Each group consisted of 20 patients. All measurements had a coefficient of variation less than 10%. The most consistent parameter for both groups was the total macular volume. Discussion: Consistency in measurement is a mainstay of any test. A test is unreliable if its measurements can not be correctly repeated. We found a good index of consistency, even considering patients with an unstable gaze. Conclusions: Optical coherence tomography is a consistent method for diabetic subjects with diffuse macular edema. (author)

  3. On multi-spectral quantitative photoacoustic tomography in diffusive regime

    International Nuclear Information System (INIS)

    Bal, Guillaume; Ren, Kui

    2012-01-01

    The objective of quantitative photoacoustic tomography (qPAT) is to reconstruct the diffusion, absorption and Grüneisen thermodynamic coefficients of heterogeneous media from knowledge of the interior absorbed radiation. It has been shown in Bal and Ren (2011 Inverse Problems 27 075003), based on diffusion theory, that with data acquired at one given wavelength, all three coefficients cannot be reconstructed uniquely. In this work, we study the multi-spectral qPAT problem and show that when multiple wavelength data are available, all coefficients can be reconstructed simultaneously under minor prior assumptions. Moreover, the reconstructions are shown to be very stable. We present some numerical simulations that support the theoretical results. (paper)

  4. Frequency domain fluorescence diffuse tomography of small animals

    Science.gov (United States)

    Orlova, Anna G.; Turchin, Ilya V.; Kamensky, Vladislav A.; Plehanov, Vladimir I.; Balalaeva, Irina V.; Sergeeva, Ekaterina A.; Shirmanova, Marina V.; Kleshnin, Michail S.

    2007-05-01

    Fluorescent compounds for selective cancer cell marking are used for development of novel medical diagnostic methods, investigation of the influence of external factors on tumor growth, regress and metastasis. Only special tools for turbid media imaging, such as optical diffusion tomography permit noninvasive monitoring of fluorescent-labeled tumor alterations deep in animal tissue. In this work, the results of preliminary experiments utilizing frequency-domain fluorescent diffusion tomography (FD FDT) experimental setup in small animal are presented. Low-frequency modulated light (1 kHz) from Nd:YAG laser with second harmonic generation at the wavelength of 532 nm was used in the setup. The transilluminative planar configuration was used in the setup. A series of model experiments has been conducted and show good agreement between theoretical and experimental fluorescence intensity. Models of deep tumors were created by two methods: (1) glass capsules containing fluorophore solution were inserted into esophagus of small animals to simulate marked tumors; (2) a suspension of transfected HEΚ293-Turbo-RFP cells was subcutaneously injected to small animal. The conducted experiments have shown that FD FDT allows one to detect the presence of labeled tumor cells in small animals, to determine the volume of an experimental tumor, to perform 3D tumor reconstruction, as well as to conduct monitoring investigations. The obtained results demonstrate the potential capability of the FD FDT method for noninvasive whole-body imaging in cancer studies, diagnostics and therapy.

  5. Low-cost diffuse optical tomography for the classroom

    Science.gov (United States)

    Minagawa, Taisuke; Zirak, Peyman; Weigel, Udo M.; Kristoffersen, Anna K.; Mateos, Nicolas; Valencia, Alejandra; Durduran, Turgut

    2012-10-01

    Diffuse optical tomography (DOT) is an emerging imaging modality with potential applications in oncology, neurology, and other clinical areas. It allows the non-invasive probing of the tissue function using relatively inexpensive and safe instrumentation. An educational laboratory setup of a DOT system could be used to demonstrate how photons propagate through tissues, basics of medical tomography, and the concepts of multiple scattering and absorption. Here, we report a DOT setup that could be introduced to the advanced undergraduate or early graduate curriculum using inexpensive and readily available tools. The basis of the system is the LEGO Mindstorms NXT platform which controls the light sources, the detectors (photo-diodes), a mechanical 2D scanning platform, and the data acquisition. A basic tomographic reconstruction is implemented in standard numerical software, and 3D images are reconstructed. The concept was tested and developed in an educational environment that involved a high-school student and a group of post-doctoral fellows.

  6. Fluorine-18-fluorodeoxyglucose Positron Emission Tomography in Diffuse Large B-cell Lymphoma

    DEFF Research Database (Denmark)

    Mylam, Karen Juul; Nielsen, Anne Lerberg; Pedersen, Lars Møller

    2014-01-01

    Diffuse large B-cell lymphoma (DLBCL) is an aggressive and potentially curable type of lymphoma. Fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) is part of clinical routine for DLBCL in most hospitals and also recommended for staging and end-of-therapy evaluation. FDG......-PET/computed tomography (CT) is able to identify nodal and extranodal sites with greater accuracy than CT alone. Little evidence supports the use of surveillance FDG-PET imaging in the follow-up setting because of high rates of false-positive scans and because most studies are retrospective. This article discusses FDG...

  7. One step linear reconstruction method for continuous wave diffuse optical tomography

    Science.gov (United States)

    Ukhrowiyah, N.; Yasin, M.

    2017-09-01

    The method one step linear reconstruction method for continuous wave diffuse optical tomography is proposed and demonstrated for polyvinyl chloride based material and breast phantom. Approximation which used in this method is selecting regulation coefficient and evaluating the difference between two states that corresponding to the data acquired without and with a change in optical properties. This method is used to recovery of optical parameters from measured boundary data of light propagation in the object. The research is demonstrated by simulation and experimental data. Numerical object is used to produce simulation data. Chloride based material and breast phantom sample is used to produce experimental data. Comparisons of results between experiment and simulation data are conducted to validate the proposed method. The results of the reconstruction image which is produced by the one step linear reconstruction method show that the image reconstruction almost same as the original object. This approach provides a means of imaging that is sensitive to changes in optical properties, which may be particularly useful for functional imaging used continuous wave diffuse optical tomography of early diagnosis of breast cancer.

  8. A study of MRI-guided diffuse fluorescence molecular tomography for monitoring PDT effects in pancreas cancer

    Science.gov (United States)

    Samkoe, Kimberley S.; Davis, Scott C.; Srinivasan, Subhadra; O'Hara, Julia A.; Hasan, Tayyaba; Pogue, Brian W.

    2009-06-01

    Over the last several decades little progress has been made in the therapy and treatment monitoring of pancreas adenocarcinoma, a devastating and aggressive form of cancer that has a 5-year patient survival rate of 3%. Currently, investigations for the use of interstitial Verteporfin photodynamic therapy (PDT) are being undertaken in both orthotopic xenograft mouse models and in human clinical trials. In the mouse models, magnetic resonance (MR) imaging has been used as a measure of surrogate response to Verteporfin PDT; however, MR imaging alone lacks the molecular information required to assess the metabolic function and growth rates of the tumor immediately after treatment. We propose the implementation of MR-guided fluorescence tomography in conjunction with a fluorescently labeled (IR-Dye 800 CW, LI-COR) epidermal growth factor (EGF) as a molecular measure of surrogate response. To demonstrate the effectiveness of MR-guided diffuse fluorescence tomography for molecular imaging, we have used the AsPC-1 (+EGFR) human pancreatic adenocarcinoma in an orthotopic mouse model. EGF IRDye 800CW was injected 48 hours prior to imaging. MR image sequences were collected simultaneously with the fluorescence data using a MR-coupled diffuse optical tomography system. Image reconstruction was performed multiple times with varying abdominal organ segmentation in order to obtain a optimal tomographic image. It is shown that diffuse fluorescence tomography of the orthotopic pancreas model is feasible, with consideration of confounding fluorescence signals from the multiple organs and tissues surrounding the pancreas. MR-guided diffuse fluorescence tomography will be used to monitor EGF response after photodynamic therapy. Additionally, it provide the opportunity to individualize subsequent therapies based on response to PDT as well as to evaluate the success of combination therapies, such as PDT with chemotherapy, antibody therapy or even radiation.

  9. Fluorescence diffuse tomography for tumor detection and monitoring

    Science.gov (United States)

    Balalaeva, Irina V.; Orlova, Anna G.; Shirmanova, Marina V.; Kibraeva, Elena A.; Zagainova, Elena V.; Turchin, Ilya V.

    2007-05-01

    Strong light scattering and absorption limit visualization of the internal structure of biological tissue. Only special tools for turbid media imaging, such as optical diffuse tomography, enable noninvasive investigation of the internal biological tissues, including visualization and intravital monitoring of deep tumors. In this work the preliminary results of fluorescence diffuse tomography (FDT) of small animals are presented. Using of exogenous fluorophores, targeted specifically at tumor cells, and fluorescent proteins expressed endogenously can significantly increase the contrast of obtained images. Fluorescent compounds of different nature, such as sulphonated aluminium phthalocyanine (Photosens), red fluorescing proteins and CdTe/CdSe-core/shell nanocrystals (quantum dots) were applied. The animal was scanned in the transilluminative configuration by low-frequency modulated light (1 kHz) from Nd:YAG laser with second harmonic generation at the wavelength of 532 nm or semiconductor laser at the wavelength of 655 nm. Photosens was injected intravenously into linear mice with metastazing Lewis lung carcinoma in dose 4 mg/kg. Quantum dots (5x10 -11 M) or protein DsRed2 (1-5x10 -6 M) in glass capsules (inner diameter 2-3 mm) were placed inside the esophagus of 7-day-old hairless rats (18-20 g) to simulate marked tumors. Cells of HEK-293 Phoenix line, transitory transfected with Turbo-RFP protein gene, were injected hypodermically to immunodeficient mice. This work demonstrates potential capabilities of FDT method for detection and monitoring of deep fluorescent-labeled tumors in animal models. Strong advantages of fluorescent proteins and quantum dots over the traditional photosensitizer for FDT imaging are shown.

  10. Experimental investigation of the diffusion coefficients in porous media by application of X-ray computer tomography

    DEFF Research Database (Denmark)

    Zhelezny, Petr; Shapiro, Alexander

    2006-01-01

    The present work describes a new experimental method that makes it possible to investigate diffusion coefficients in a porous medium. The method is based on application of X-ray computed tomography (CT). The general applicability of this method for the determination of diffusion coefficients...

  11. Design of optoelectronic system for optical diffusion tomography

    Directory of Open Access Journals (Sweden)

    Erakhtin Igor

    2017-01-01

    Full Text Available This article explores issues connected with the circuit design of a device for optical diffusion tomography, which we are currently designing. We plan to use the device in experimental studies for the development of a faster method of brain hematoma detection. We reviewed currently existing methods for emergency diagnosis of hematomas, primarily the Infrascanner model 2000, for which we identified weaknesses, and outlined suggestions for improvements. This article describes the method of scanning tissues based on a triangulated arrangement of sources and receivers of optical radiation, and it discusses the optoelectronic system that implements that principle.

  12. Comparisons of hybrid radiosity-diffusion model and diffusion equation for bioluminescence tomography in cavity cancer detection

    Science.gov (United States)

    Chen, Xueli; Yang, Defu; Qu, Xiaochao; Hu, Hao; Liang, Jimin; Gao, Xinbo; Tian, Jie

    2012-06-01

    Bioluminescence tomography (BLT) has been successfully applied to the detection and therapeutic evaluation of solid cancers. However, the existing BLT reconstruction algorithms are not accurate enough for cavity cancer detection because of neglecting the void problem. Motivated by the ability of the hybrid radiosity-diffusion model (HRDM) in describing the light propagation in cavity organs, an HRDM-based BLT reconstruction algorithm was provided for the specific problem of cavity cancer detection. HRDM has been applied to optical tomography but is limited to simple and regular geometries because of the complexity in coupling the boundary between the scattering and void region. In the provided algorithm, HRDM was first applied to three-dimensional complicated and irregular geometries and then employed as the forward light transport model to describe the bioluminescent light propagation in tissues. Combining HRDM with the sparse reconstruction strategy, the cavity cancer cells labeled with bioluminescent probes can be more accurately reconstructed. Compared with the diffusion equation based reconstruction algorithm, the essentiality and superiority of the HRDM-based algorithm were demonstrated with simulation, phantom and animal studies. An in vivo gastric cancer-bearing nude mouse experiment was conducted, whose results revealed the ability and feasibility of the HRDM-based algorithm in the biomedical application of gastric cancer detection.

  13. Multi-source quantitative photoacoustic tomography in a diffusive regime

    International Nuclear Information System (INIS)

    Bal, Guillaume; Ren, Kui

    2011-01-01

    Photoacoustic tomography (PAT) is a novel hybrid medical imaging technique that aims to combine the large contrast of optical coefficients with the high-resolution capabilities of ultrasound. We assume that the first step of PAT, namely the reconstruction of a map of absorbed radiation from ultrasound boundary measurement, has been done. We focus on quantitative photoacoustic tomography, which aims at quantitatively reconstructing the optical coefficients from knowledge of the absorbed radiation map. We present a non-iterative procedure to reconstruct such optical coefficients, namely the diffusion and absorption coefficients, and the Grüneisen coefficient when the propagation of radiation is modeled by a second-order elliptic equation. We show that PAT measurements allow us to uniquely reconstruct only two out of the above three coefficients, even when data are collected using an arbitrary number of radiation illuminations. We present uniqueness and stability results for the reconstructions of two such parameters and demonstrate the accuracy of the reconstruction algorithm with numerical reconstructions from two-dimensional synthetic data

  14. Diffuse optical tomography with physiological and spatial a priori constraints

    International Nuclear Information System (INIS)

    Intes, Xavier; Maloux, Clemence; Guven, Murat; Yazici, Birzen; Chance, Britton

    2004-01-01

    Diffuse optical tomography is a typical inverse problem plagued by ill-condition. To overcome this drawback, regularization or constraining techniques are incorporated in the inverse formulation. In this work, we investigate the enhancement in recovering functional parameters by using physiological and spatial a priori constraints. More accurate recovery of the two main functional parameters that are the blood volume and the relative saturation is demonstrated through simulations by using our method compared to actual techniques. (note)

  15. Theoretical limit of spatial resolution in diffuse optical tomography using a perturbation model

    International Nuclear Information System (INIS)

    Konovalov, A B; Vlasov, V V

    2014-01-01

    We have assessed the limit of spatial resolution of timedomain diffuse optical tomography (DOT) based on a perturbation reconstruction model. From the viewpoint of the structure reconstruction accuracy, three different approaches to solving the inverse DOT problem are compared. The first approach involves reconstruction of diffuse tomograms from straight lines, the second – from average curvilinear trajectories of photons and the third – from total banana-shaped distributions of photon trajectories. In order to obtain estimates of resolution, we have derived analytical expressions for the point spread function and modulation transfer function, as well as have performed a numerical experiment on reconstruction of rectangular scattering objects with circular absorbing inhomogeneities. It is shown that in passing from reconstruction from straight lines to reconstruction using distributions of photon trajectories we can improve resolution by almost an order of magnitude and exceed the accuracy of reconstruction of multi-step algorithms used in DOT. (optical tomography)

  16. Fluorescence diffuse optical tomography: benefits of using the time-resolved modality

    International Nuclear Information System (INIS)

    Ducros, Nicolas

    2009-01-01

    Fluorescence diffuse optical tomography enables the three-dimensional reconstruction of fluorescence markers injected within a biological tissue, with light in the near infrared range. The simple continuous modality uses steady excitation light and operates from the measurements at different positions of the attenuation of the incident beam. This technique is low-cost, non-ionizing, and easy to handle, but subject to low resolution for thick tissues due to diffusion. Hopefully, the time-resolved modality, which provides the time of flight of any detected photon, could overcome this limitation and pave the way to clinical applications. This thesis aims at determining the best way to exploit the time resolved information and at quantifying the advantages of this modality over the standard continuous wave one. Model deviations must be carefully limited when ill-posed problems as fluorescence diffuse optical tomography are considered. As a result, we have first addressed the modelling part of the problem. We have shown that the photons density models to good approximation the measurable quantity that is the quantity measured by an actual acquisition set-up. Then, the moment-based reconstruction scheme has been thoroughly evaluated by means of a theoretical analysis of the moments properties. It was found that the moment-based approach requires high photon counts to be profitable compared to the continuous wave modality. Last, a novel wavelet-based approach, which enables an improved reconstruction quality, has been introduced. This approach has shown good ability to exploit the temporal information at lower photon counts. (author) [fr

  17. Évaluation des caractéristiques mécaniques du polissoir en polyuréthanne utilisé comme porte abrasifs durant le processus du polissage du verre optique

    Science.gov (United States)

    Aliouane, T.; Bouzid, D.; Belkhir, N.; Bouzid, S.; Herold, V.

    2005-05-01

    La fabrication des composants en verre optique nécessite des moyens de grande précision dans les procédés de finition vue l'importance accordée à leur qualité.
Durant le processus de polissage des verres optiques, le polissoir est un élément clé et a un impact direct sur les performances des composants optiques, non seulement il est utilisé comme support de grains abrasifs mais il doit posséder la fonction de transmission de la pression aux grains. La connaissance de ses propriétés, essentiellement mécanique, est impérative afin d'obtenir un état de surface optimal des composants optiques destinés à remplir des fonctions très précises dans des appareils optiques très performants.
Dans cette étude, nous avons constaté que les propriétés des polissoirs en polyuréthanne tel que la dureté, le module d'élasticité et la densité varient au cours du polissage. Ce changement a des effets sur l'état de surface de verre optique, causé par le changement microstructural de la surface du polissoir (distribution et dimensions des pores) et par conséquent sur la quantité des abrasifs (en oxyde de cérium) insérée dans les pores, ce qui influe sur la quantité de verre enlevée et sur l'état de surface du composant.
Sur la base des résultats obtenus, il a été prouvé que le polissoir subit des modifications très importantes ce qui influe considérablement sur son efficacité de polissage.

  18. Reflectance diffuse optical tomography. Its application to human brain mapping

    International Nuclear Information System (INIS)

    Ueda, Yukio; Yamanaka, Takeshi; Yamashita, Daisuke; Suzuki, Toshihiko; Ohmae, Etsuko; Oda, Motoki; Yamashita, Yutaka

    2005-01-01

    We report the successful application of reflectance diffuse optical tomography (DOT) using near-infrared light with the new reconstruction algorithm that we developed to the observation of regional hemodynamic changes in the brain under specific mental tasks. Our results reveal the heterogeneous distribution of oxyhemoglobin and deoxyhemoglobin in the brain, showing complementary images of oxyhemoglobin and deoxyhemoglobin changes in certain regions. We conclude that our reflectance DOT has practical potential for human brain mapping, as well as in the diagnostic imaging of brain diseases. (author)

  19. Controle optique de qubits lies a des centres isoelectroniques d'azote dans le GaAs

    Science.gov (United States)

    Ethier-Majcher, Gabriel

    Le traitement de l'information quantique est un domaine de recherche actuellement en pleine effervescence car il laisse entrevoir une revolution dans notre facon de traiter et d'echanger de l'information. D'une part, l'ordinateur quantique promet de resoudre des problemes comme la factorisation d'un polynome de facon beaucoup plus efficace qu'un ordinateur classique. D'autre part, les communications quantiques promettent l'echange d'information de facon fondamentalement inviolable. Afin de tirer pleinement profit de ces nouvelles technologies, il sera avantageux de construire des reseaux quantiques. Dans un tel reseau, des processeurs quantiques, les noeuds, seront connectes par des photons voyageant dans des fibres optiques. Les reseaux quantiques permettront de deployer les communications quantiques a grande echelle et de creer des super-ordinateurs quantiques. La realisation de reseaux quantiques necessitera des interfaces optiques pouvant echanger l'information de facon coherente entre un qubit (bit d'information quantique) et un photon. L'implementation de telles interfaces dans un systeme physique s'avere un important defi scientifique et technologique. Or, les systemes actuellement envisages a cette fin souffrent d'un faible couplage avec la lumiere ou encore de grandes inhomogeneites, constituant des obstacles a la realisation de reseaux a grande echelle. Dans cette these, le potentiel des centres isoelectroniques pour realiser des interfaces optiques est evalue. Deux types de qubits lies a des paires d'azote dans le GaAs sont consideres : les qubits excitoniques et les qubits de spin electronique, controlables par l'intermediaire d'excitons charges. Le controle optique complet des qubits excitoniques est demontre, ce qui constitue la premiere realisation du genre dans les centres isoelectroniques. L'observation d'excitons charges dans ce systeme, liant a la fois des trous lourds et des trous legers, laisse entrevoir de nouvelles possibilites afin de

  20. Greedy algorithms for diffuse optical tomography reconstruction

    Science.gov (United States)

    Dileep, B. P. V.; Das, Tapan; Dutta, Pranab K.

    2018-03-01

    Diffuse optical tomography (DOT) is a noninvasive imaging modality that reconstructs the optical parameters of a highly scattering medium. However, the inverse problem of DOT is ill-posed and highly nonlinear due to the zig-zag propagation of photons that diffuses through the cross section of tissue. The conventional DOT imaging methods iteratively compute the solution of forward diffusion equation solver which makes the problem computationally expensive. Also, these methods fail when the geometry is complex. Recently, the theory of compressive sensing (CS) has received considerable attention because of its efficient use in biomedical imaging applications. The objective of this paper is to solve a given DOT inverse problem by using compressive sensing framework and various Greedy algorithms such as orthogonal matching pursuit (OMP), compressive sampling matching pursuit (CoSaMP), and stagewise orthogonal matching pursuit (StOMP), regularized orthogonal matching pursuit (ROMP) and simultaneous orthogonal matching pursuit (S-OMP) have been studied to reconstruct the change in the absorption parameter i.e, Δα from the boundary data. Also, the Greedy algorithms have been validated experimentally on a paraffin wax rectangular phantom through a well designed experimental set up. We also have studied the conventional DOT methods like least square method and truncated singular value decomposition (TSVD) for comparison. One of the main features of this work is the usage of less number of source-detector pairs, which can facilitate the use of DOT in routine applications of screening. The performance metrics such as mean square error (MSE), normalized mean square error (NMSE), structural similarity index (SSIM), and peak signal to noise ratio (PSNR) have been used to evaluate the performance of the algorithms mentioned in this paper. Extensive simulation results confirm that CS based DOT reconstruction outperforms the conventional DOT imaging methods in terms of

  1. Etudes optiques de nouveaux materiaux laser: Des orthosilicates dopes a l'ytterbium: Le yttrium (lutetium,scandium) pentoxide de silicium

    Science.gov (United States)

    Denoyer, Aurelie

    La decouverte et l'elaboration de nouveaux materiaux laser solides suscitent beaucoup d'interet parmi la communaute scientifique. En particulier les lasers dans la gamme de frequence du micron debouchent sur beaucoup d'applications, en telecommunication, en medecine, dans le domaine militaire, pour la, decoupe des metaux (lasers de puissance), en optique non lineaire (doublage de frequence, bistabilite optique). Le plus couramment utilise actuellement est le Nd:YAG dans cette famille de laser, mais des remplacants plus performants sont toujours recherches. Les lasers a base d'Yb3+ possedent beaucoup d'avantages compares aux lasers Nd3+ du fait de leur structure electronique simple et de leur deterioration moins rapide. Parmi les matrices cristallines pouvant accueillir l'ytterbium, les orthosilicates Yb:Y 2SiO5, Yb:Lu2SiO5 et Yb:Sc2SiO 5 se positionnent tres bien, du fait de leur bonne conductivite thermique et du fort eclatement de leur champ cristallin necessaire a l'elaboration de lasers quasi-3 niveaux. De plus l'etude fine et systematique des proprietes microscopiques de nouveaux materiaux s'avere toujours tres interessante du point de vue de la recherche fondamentale, c'est ainsi que de nouveaux modeles sont concus (par exemple pour le champ cristallin) ou que de nouvelles proprietes inhabituelles sont decouvertes, menant a de nouvelles applications. Ainsi d'autres materiaux dopes a l'ytterbium sont connus pour leurs proprietes de couplage electron-phonon, de couplage magnetique, d'emission cooperative ou encore de bistabilite optique, mais ces proprietes n'ont encore jamais ete mises en evidence dans Yb:Y 2SiO5, Yb:Lu2SiO5 et Yb:Sc2SiO 5. Ainsi, cette these a pour but l'etude des proprietes optiques et des interactions microscopiques dans Yb:Y2SiO 5, Yb:Lu2SiO5 et Yb:Sc2SiO5. Nous utilisons principalement les techniques d'absorption IR et de spectroscopie Raman pour determiner les excitations du champ cristallin et les modes de vibration dans le materiau

  2. Diffuse correlation tomography reveals spatial and temporal difference in blood flow changes among murine femoral grafts

    Science.gov (United States)

    Han, Songfeng; Proctor, Ashley R.; Benoit, Danielle S. W.; Choe, Regine

    2017-07-01

    Diffuse correlation tomography was utilized to noninvasively monitor 3D blood flow changes in three types of healing mouse femoral grafts. Results reveal the spatial and temporal difference among the groups.

  3. Algebraic reconstruction techniques for spectral reconstruction in diffuse optical tomography

    International Nuclear Information System (INIS)

    Brendel, Bernhard; Ziegler, Ronny; Nielsen, Tim

    2008-01-01

    Reconstruction in diffuse optical tomography (DOT) necessitates solving the diffusion equation, which is nonlinear with respect to the parameters that have to be reconstructed. Currently applied solving methods are based on the linearization of the equation. For spectral three-dimensional reconstruction, the emerging equation system is too large for direct inversion, but the application of iterative methods is feasible. Computational effort and speed of convergence of these iterative methods are crucial since they determine the computation time of the reconstruction. In this paper, the iterative methods algebraic reconstruction technique (ART) and conjugated gradients (CGs) as well as a new modified ART method are investigated for spectral DOT reconstruction. The aim of the modified ART scheme is to speed up the convergence by considering the specific conditions of spectral reconstruction. As a result, it converges much faster to favorable results than conventional ART and CG methods

  4. Multiple projection optical diffusion tomography with plane wave illumination

    International Nuclear Information System (INIS)

    Markel, Vadim A; Schotland, John C

    2005-01-01

    We describe a new data collection scheme for optical diffusion tomography in which plane wave illumination is combined with multiple projections in the slab imaging geometry. Multiple projection measurements are performed by rotating the slab around the sample. The advantage of the proposed method is that the measured data are more compatible with the dynamic range of most commonly used detectors. At the same time, multiple projections improve image quality by mutually interchanging the depth and transverse directions, and the scanned (detection) and integrated (illumination) surfaces. Inversion methods are derived for image reconstructions with extremely large data sets. Numerical simulations are performed for fixed and rotated slabs

  5. Speckle contrast diffuse correlation tomography of complex turbid medium flow

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chong; Irwin, Daniel; Lin, Yu; Shang, Yu; He, Lian; Kong, Weikai; Yu, Guoqiang [Department of Biomedical Engineering, University of Kentucky, Lexington, Kentucky 40506 (United States); Luo, Jia [Department of Pharmacology and Nutritional Sciences, University of Kentucky, Lexington, Kentucky 40506 (United States)

    2015-07-15

    Purpose: Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckle contrast diffuse correlation tomography (scDCT), enables incorporation of complex optical property heterogeneities and sample boundaries. When combined with a reflectance-based design, this system facilitates a rapid segue into flow contrast imaging of larger, in vivo applications such as humans. Methods: A highly sensitive CCD camera was integrated into a reflectance-based optical system. Four long-coherence laser source positions were coupled to an optical switch for sequencing of tomographic data acquisition providing multiple projections through the sample. This system was investigated through incorporation of liquid and solid tissue-like phantoms exhibiting optical properties and flow characteristics typical of human tissues. Computer simulations were also performed for comparisons. A uniquely encountered smear correction algorithm was employed to correct point-source illumination contributions during image capture with the frame-transfer CCD and reflectance setup. Results: Measurements with scDCT on a homogeneous liquid phantom showed that speckle contrast-based deep flow indices were within 12% of those from standard DCT. Inclusion of a solid phantom submerged below the liquid phantom surface allowed for heterogeneity detection and validation. The heterogeneity was identified successfully by reconstructed 3D flow contrast tomography with scDCT. The heterogeneity center and dimensions and averaged relative flow (within 3%) and localization were in agreement with actuality and computer simulations, respectively. Conclusions: A custom cost-effective CCD-based reflectance 3D flow imaging system demonstrated rapid acquisition of dense boundary

  6. Influence of supersaturated carbon on the diffusion of Ni in ferrite determined by atom probe tomography

    KAUST Repository

    Kresse, T.; Li, Yujiao; Boll, Torben; Borchers, Christine; Choi, Pyuckpa; Al-Kassab, Talaat; Raabe, Dierk; Kirchheim, Reiner

    2013-01-01

    In patented and cold-drawn pearlitic steel wires dissociation of cementite occurs during mechanical deformation. In this study the influence of the carbon decomposition on the diffusion of nickel in ferrite is investigated by means of atom probe tomography. In the temperature range 423-523 K we observed a much smaller activation energy of Ni diffusion than for self-diffusion in body-centered cubic iron, indicating an increased vacancy density owing to enhanced formation of vacancy-carbon complexes. © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  7. Influence of supersaturated carbon on the diffusion of Ni in ferrite determined by atom probe tomography

    KAUST Repository

    Kresse, T.

    2013-09-01

    In patented and cold-drawn pearlitic steel wires dissociation of cementite occurs during mechanical deformation. In this study the influence of the carbon decomposition on the diffusion of nickel in ferrite is investigated by means of atom probe tomography. In the temperature range 423-523 K we observed a much smaller activation energy of Ni diffusion than for self-diffusion in body-centered cubic iron, indicating an increased vacancy density owing to enhanced formation of vacancy-carbon complexes. © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  8. Diffuse Optical Tomography for Brain Imaging: Theory

    Science.gov (United States)

    Yuan, Zhen; Jiang, Huabei

    Diffuse optical tomography (DOT) is a noninvasive, nonionizing, and inexpensive imaging technique that uses near-infrared light to probe tissue optical properties. Regional variations in oxy- and deoxy-hemoglobin concentrations as well as blood flow and oxygen consumption can be imaged by monitoring spatiotemporal variations in the absorption spectra. For brain imaging, this provides DOT unique abilities to directly measure the hemodynamic, metabolic, and neuronal responses to cells (neurons), and tissue and organ activations with high temporal resolution and good tissue penetration. DOT can be used as a stand-alone modality or can be integrated with other imaging modalities such as fMRI/MRI, PET/CT, and EEG/MEG in studying neurophysiology and pathology. This book chapter serves as an introduction to the basic theory and principles of DOT for neuroimaging. It covers the major aspects of advances in neural optical imaging including mathematics, physics, chemistry, reconstruction algorithm, instrumentation, image-guided spectroscopy, neurovascular and neurometabolic coupling, and clinical applications.

  9. Measurement of shear-induced diffusion of red blood cells using dynamic light scattering-optical coherence tomography

    Science.gov (United States)

    Tang, Jianbo; Erdener, Sefik Evren; Li, Baoqiang; Fu, Buyin; Sakadzic, Sava; Carp, Stefan A.; Lee, Jonghwan; Boas, David A.

    2018-02-01

    Dynamic Light Scattering-Optical Coherence Tomography (DLS-OCT) takes the advantages of using DLS to measure particle flow and diffusion within an OCT resolution-constrained 3D volume, enabling the simultaneous measurements of absolute RBC velocity and diffusion coefficient with high spatial resolution. In this work, we applied DLS-OCT to measure both RBC velocity and the shear-induced diffusion coefficient within penetrating venules of the somatosensory cortex of anesthetized mice. Blood flow laminar profile measurements indicate a blunted laminar flow profile, and the degree of blunting decreases with increasing vessel diameter. The measured shear-induced diffusion coefficient was proportional to the flow shear rate with a magnitude of 0.1 to 0.5 × 10-6 mm2 . These results provide important experimental support for the recent theoretical explanation for why DCS is dominantly sensitive to RBC diffusive motion.

  10. Diffuse optical tomography using semiautomated coregistered ultrasound measurements

    Science.gov (United States)

    Mostafa, Atahar; Vavadi, Hamed; Uddin, K. M. Shihab; Zhu, Quing

    2017-12-01

    Diffuse optical tomography (DOT) has demonstrated huge potential in breast cancer diagnosis and treatment monitoring. DOT image reconstruction guided by ultrasound (US) improves the diffused light localization and lesion reconstruction accuracy. However, DOT reconstruction depends on tumor geometry provided by coregistered US. Experienced operators can manually measure these lesion parameters; however, training and measurement time are needed. The wide clinical use of this technique depends on its robustness and faster imaging reconstruction capability. This article introduces a semiautomated procedure that automatically extracts lesion information from US images and incorporates it into the optical reconstruction. An adaptive threshold-based image segmentation is used to obtain tumor boundaries. For some US images, posterior shadow can extend to the chest wall and make the detection of deeper lesion boundary difficult. This problem can be solved using a Hough transform. The proposed procedure was validated from data of 20 patients. Optical reconstruction results using the proposed procedure were compared with those reconstructed using extracted tumor information from an experienced user. Mean optical absorption obtained from manual measurement was 0.21±0.06 cm-1 for malignant and 0.12±0.06 cm-1 for benign cases, whereas for the proposed method it was 0.24±0.08 cm-1 and 0.12±0.05 cm-1, respectively.

  11. Diffuse optical tomography for breast cancer imaging guided by computed tomography: A feasibility study.

    Science.gov (United States)

    Baikejiang, Reheman; Zhang, Wei; Li, Changqing

    2017-01-01

    Diffuse optical tomography (DOT) has attracted attentions in the last two decades due to its intrinsic sensitivity in imaging chromophores of tissues such as hemoglobin, water, and lipid. However, DOT has not been clinically accepted yet due to its low spatial resolution caused by strong optical scattering in tissues. Structural guidance provided by an anatomical imaging modality enhances the DOT imaging substantially. Here, we propose a computed tomography (CT) guided multispectral DOT imaging system for breast cancer imaging. To validate its feasibility, we have built a prototype DOT imaging system which consists of a laser at the wavelength of 650 nm and an electron multiplying charge coupled device (EMCCD) camera. We have validated the CT guided DOT reconstruction algorithms with numerical simulations and phantom experiments, in which different imaging setup parameters, such as projection number of measurements and width of measurement patch, have been investigated. Our results indicate that an air-cooling EMCCD camera is good enough for the transmission mode DOT imaging. We have also found that measurements at six angular projections are sufficient for DOT to reconstruct the optical targets with 2 and 4 times absorption contrast when the CT guidance is applied. Finally, we have described our future research plan on integration of a multispectral DOT imaging system into a breast CT scanner.

  12. Pseudodynamic systems approach based on a quadratic approximation of update equations for diffuse optical tomography.

    Science.gov (United States)

    Biswas, Samir Kumar; Kanhirodan, Rajan; Vasu, Ram Mohan; Roy, Debasish

    2011-08-01

    We explore a pseudodynamic form of the quadratic parameter update equation for diffuse optical tomographic reconstruction from noisy data. A few explicit and implicit strategies for obtaining the parameter updates via a semianalytical integration of the pseudodynamic equations are proposed. Despite the ill-posedness of the inverse problem associated with diffuse optical tomography, adoption of the quadratic update scheme combined with the pseudotime integration appears not only to yield higher convergence, but also a muted sensitivity to the regularization parameters, which include the pseudotime step size for integration. These observations are validated through reconstructions with both numerically generated and experimentally acquired data.

  13. Patch-based anisotropic diffusion scheme for fluorescence diffuse optical tomography--part 2: image reconstruction.

    Science.gov (United States)

    Correia, Teresa; Koch, Maximilian; Ale, Angelique; Ntziachristos, Vasilis; Arridge, Simon

    2016-02-21

    Fluorescence diffuse optical tomography (fDOT) provides 3D images of fluorescence distributions in biological tissue, which represent molecular and cellular processes. The image reconstruction problem is highly ill-posed and requires regularisation techniques to stabilise and find meaningful solutions. Quadratic regularisation tends to either oversmooth or generate very noisy reconstructions, depending on the regularisation strength. Edge preserving methods, such as anisotropic diffusion regularisation (AD), can preserve important features in the fluorescence image and smooth out noise. However, AD has limited ability to distinguish an edge from noise. We propose a patch-based anisotropic diffusion regularisation (PAD), where regularisation strength is determined by a weighted average according to the similarity between patches around voxels within a search window, instead of a simple local neighbourhood strategy. However, this method has higher computational complexity and, hence, we wavelet compress the patches (PAD-WT) to speed it up, while simultaneously taking advantage of the denoising properties of wavelet thresholding. Furthermore, structural information can be incorporated into the image reconstruction with PAD-WT to improve image quality and resolution. In this case, the weights used to average voxels in the image are calculated using the structural image, instead of the fluorescence image. The regularisation strength depends on both structural and fluorescence images, which guarantees that the method can preserve fluorescence information even when it is not structurally visible in the anatomical images. In part 1, we tested the method using a denoising problem. Here, we use simulated and in vivo mouse fDOT data to assess the algorithm performance. Our results show that the proposed PAD-WT method provides high quality and noise free images, superior to those obtained using AD.

  14. Shear-induced diffusion of red blood cells measured with dynamic light scattering-optical coherence tomography.

    Science.gov (United States)

    Tang, Jianbo; Erdener, Sefik Evren; Li, Baoqiang; Fu, Buyin; Sakadzic, Sava; Carp, Stefan A; Lee, Jonghwan; Boas, David A

    2018-02-01

    Quantitative measurements of intravascular microscopic dynamics, such as absolute blood flow velocity, shear stress and the diffusion coefficient of red blood cells (RBCs), are fundamental in understanding the blood flow behavior within the microcirculation, and for understanding why diffuse correlation spectroscopy (DCS) measurements of blood flow are dominantly sensitive to the diffusive motion of RBCs. Dynamic light scattering-optical coherence tomography (DLS-OCT) takes the advantages of using DLS to measure particle flow and diffusion within an OCT resolution-constrained three-dimensional volume, enabling the simultaneous measurements of absolute RBC velocity and diffusion coefficient with high spatial resolution. In this work, we applied DLS-OCT to measure both RBC velocity and the shear-induced diffusion coefficient within penetrating venules of the somatosensory cortex of anesthetized mice. Blood flow laminar profile measurements indicate a blunted laminar flow profile and the degree of blunting decreases with increasing vessel diameter. The measured shear-induced diffusion coefficient was proportional to the flow shear rate with a magnitude of ~0.1 to 0.5 × 10 -6  mm 2 . These results provide important experimental support for the recent theoretical explanation for why DCS is dominantly sensitive to RBC diffusive motion. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Fluorescence diffuse tomography of small animals with DsRed2 fluorescent protein

    Science.gov (United States)

    Turchin, I. V.; Plehanov, V. I.; Orlova, A. G.; Kamenskiy, V. A.; Kleshnin, M. S.; Shirmanova, M. V.; Shakhova, N. M.; Balalaeva, I. V.; Savitskiy, A. P.

    2006-05-01

    Fluorescent compounds are used as markers to diagnose oncological diseases, to study molecular processes typical for carcinogenesis, and to investigate metastasis formation and tumor regress under the influence of therapeutics. Different types of tomography, such as continuous wave (CW), frequency-domain (FD), and time-domain (TD) tomography, allow fluorescence imaging of tumors located deep in human or animal tissue. In this work, preliminary results of the frequency domain fluorescent diffuse tomography (FDT) method in application to DsRed2 protein as a fluorescent agent are presented. For the first step of our experiments, we utilized low-frequency amplitude modulation (1 kHz) of second harmonic of Nd: YAG (532 nm). The transilluminative configuration was used in the setup. The results of post mortem experiments with capsules containing DsRed2 inserted inside the esophagus of a 3-day-old hairless rat to simulate tumor are shown. An algorithm of processing fluorescent images based on calculating the zero of maximum curvature has been applied to detect fluorescent inclusion boundaries in the image. This work demonstrates the potential capability of the FDT method for imaging deep fluorescent tumors in human tissue or animal models of human cancer. Improvement of the setup can be accomplished by using high-frequency modulation (using a 110-MHz acoustooptical modulator).

  16. Photons-based medical imaging - Radiology, X-ray tomography, gamma and positrons tomography, optical imaging; Imagerie medicale a base de photons - Radiologie, tomographie X, tomographie gamma et positons, imagerie optique

    Energy Technology Data Exchange (ETDEWEB)

    Fanet, H.; Dinten, J.M.; Moy, J.P.; Rinkel, J. [CEA Leti, Grenoble (France); Buvat, I. [IMNC - CNRS, Orsay (France); Da Silva, A. [Institut Fresnel, Marseille (France); Douek, P.; Peyrin, F. [INSA Lyon, Lyon Univ. (France); Frija, G. [Hopital Europeen George Pompidou, Paris (France); Trebossen, R. [CEA-Service hospitalier Frederic Joliot, Orsay (France)

    2010-07-01

    This book describes the different principles used in medical imaging. The detection aspects, the processing electronics and algorithms are detailed for the different techniques. This first tome analyses the photons-based techniques (X-rays, gamma rays and visible light). Content: 1 - physical background: radiation-matter interaction, consequences on detection and medical imaging; 2 - detectors for medical imaging; 3 - processing of numerical radiography images for quantization; 4 - X-ray tomography; 5 - positrons emission tomography: principles and applications; 6 - mono-photonic imaging; 7 - optical imaging; Index. (J.S.)

  17. Functional imaging and assessment of the glucose diffusion rate in epithelial tissues in optical coherence tomography

    International Nuclear Information System (INIS)

    Larin, K V; Tuchin, V V

    2008-01-01

    Functional imaging, monitoring and quantitative description of glucose diffusion in epithelial and underlying stromal tissues in vivo and controlling of the optical properties of tissues are extremely important for many biomedical applications including the development of noninvasive or minimally invasive glucose sensors as well as for therapy and diagnostics of various diseases, such as cancer, diabetic retinopathy, and glaucoma. Recent progress in the development of a noninvasive molecular diffusion biosensor based on optical coherence tomography (OCT) is described. The diffusion of glucose was studied in several epithelial tissues both in vitro and in vivo. Because OCT provides depth-resolved imaging of tissues with high in-depth resolution, the glucose diffusion is described not only as a function of time but also as a function of depth. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

  18. Functional imaging of small tissue volumes with diffuse optical tomography

    Science.gov (United States)

    Klose, Alexander D.; Hielscher, Andreas H.

    2006-03-01

    Imaging of dynamic changes in blood parameters, functional brain imaging, and tumor imaging are the most advanced application areas of diffuse optical tomography (DOT). When dealing with the image reconstruction problem one is faced with the fact that near-infrared photons, unlike X-rays, are highly scattered when they traverse biological tissue. Image reconstruction schemes are required that model the light propagation inside biological tissue and predict measurements on the tissue surface. By iteratively changing the tissue-parameters until the predictions agree with the real measurements, a spatial distribution of optical properties inside the tissue is found. The optical properties can be related to the tissue oxygenation, inflammation, or to the fluorophore concentration of a biochemical marker. If the model of light propagation is inaccurate, the reconstruction process will lead to an inaccurate result as well. Here, we focus on difficulties that are encountered when DOT is employed for functional imaging of small tissue volumes, for example, in cancer studies involving small animals, or human finger joints for early diagnosis of rheumatoid arthritis. Most of the currently employed image reconstruction methods rely on the diffusion theory that is an approximation to the equation of radiative transfer. But, in the cases of small tissue volumes and tissues that contain low scattering regions diffusion theory has been shown to be of limited applicability Therefore, we employ a light propagation model that is based on the equation of radiative transfer, which promises to overcome the limitations.

  19. Applicability of a geometrical model coupled to computed tomography to characterize the transport properties of porous materials: comparison with through diffusion experiments

    International Nuclear Information System (INIS)

    Chagneau, Aurelie; Claret, Francis; Made, Benoit; Tuckermann, Juergen; Enzmann, Frieder; Schaefer, Thorsten

    2012-01-01

    Document available in extended abstract form only. The main objective of the present study is to characterize the evolution of diffusion properties of porous materials as influenced by porosity changes. When under geochemical perturbation, the rocks porosity evolves with dissolution/precipitation processes. The impact of changes in porosity on the diffusion phenomena are implemented in most geochemical models using Archie's law: D e /D 0 = ε m where D e and D 0 are the effective diffusivity and the diffusivity of the element in water in m 2 s -1 , respectively, e is the overall porosity and m is the cementation factor. The factor m is a function of pores geometry and compaction. Depending on the rock considered, its value ranges from 1 to 3. Moreover, as the porosity decreases the connectivity of pores changes. At low overall porosity, the effective porosity is the determining parameter affecting effective diffusivity. Therefore, the Archie's law needs to be modified to accurately predict geochemical migration of pollutants such as radio-elements in a dynamic system. Our experimental approach is divided in two complementary parts: (i) diffusion experiments conducted in hot-laboratory using radiotracers and (ii) time-dependant monitoring of porosity evolution in three dimensions using computed tomography (CT). For the two approaches, simplified systems are used to define the co-evolution of porosity and diffusivity using a minimum number of parameters, in order to optimize the understanding of the basics and determining processes. For this purpose, three materials are used in diffusion columns: (i) rods of porous ceramic, (ii) artificial silica beads of different particle sizes (SiLi R ) and (iii) purified sea sand (Merck R ). The precipitation of simple salts, celestite (SrSO 4 ) and strontianite (SrCO 3 ), is forced in the porous material once placed in diffusion columns. Celestite and strontianite were chosen for their fast precipitation kinetics, and because

  20. Functional imaging of the human brain using a modular, fibre-less, high-density diffuse optical tomography system.

    Science.gov (United States)

    Chitnis, Danial; Cooper, Robert J; Dempsey, Laura; Powell, Samuel; Quaggia, Simone; Highton, David; Elwell, Clare; Hebden, Jeremy C; Everdell, Nicholas L

    2016-10-01

    We present the first three-dimensional, functional images of the human brain to be obtained using a fibre-less, high-density diffuse optical tomography system. Our technology consists of independent, miniaturized, silicone-encapsulated DOT modules that can be placed directly on the scalp. Four of these modules were arranged to provide up to 128, dual-wavelength measurement channels over a scalp area of approximately 60 × 65 mm 2 . Using a series of motor-cortex stimulation experiments, we demonstrate that this system can obtain high-quality, continuous-wave measurements at source-detector separations ranging from 14 to 55 mm in adults, in the presence of hair. We identify robust haemodynamic response functions in 5 out of 5 subjects, and present diffuse optical tomography images that depict functional haemodynamic responses that are well-localized in all three dimensions at both the individual and group levels. This prototype modular system paves the way for a new generation of wearable, wireless, high-density optical neuroimaging technologies.

  1. Study of continuous-wave domain fluorescence diffuse optical tomography for quality control on agricultural produce

    Energy Technology Data Exchange (ETDEWEB)

    Nadhira, Vebi, E-mail: vebi@tf.itb.ac.id; Kurniadi, Deddy, E-mail: vebi@tf.itb.ac.id; Juliastuti, E., E-mail: vebi@tf.itb.ac.id; Sutiswan, Adeline, E-mail: vebi@tf.itb.ac.id [Instrumentation and Control Research Group, Faculty of Industrial Technology, Institute Technology of Bandung, Ganesha 10 40132 Bandung (Indonesia)

    2014-03-24

    The importance of monitoring the quality of vegetables and fruits is prosperity by giving a competitive advantage for producer and providing a more healthy food for consumer. Diffuse Optical Tomography (DOT) is offering the possibility to detect the internal defects of the agricultural produce quality. Fluorescence diffuse optical tomography (FDOT) is the development of DOT, offering the possibilities to improve spatial resolution and to contrast image. The purpose of this research is to compare FDOT and DOT in forward analysis with continuous wave approach. The scattering and absorbing parameters of potatoes are used to represent the real condition. The object was illuminated by the NIR source from some positions on the boundary of object. A set of NIR detector are placed on the peripheral position of the object to measure the intensity of propagated or emitted light. In the simulation, we varied a condition of object then we analyzed the sensitivity of forward problem. The result of this study shows that FDOT has a better sensitivity than DOT and a better potential to monitor internal defects of agricultural produce because of the contrast value between optical and fluorescence properties of agricultural produce normal tissue and defects.

  2. Étude des propriétés structurales, optiques et électriques des ...

    African Journals Online (AJOL)

    Après dépôt, les couches ont été caractérisées et l'effet de la concentration du dopage de l'aluminium sur leurs propriétés structurale, optique et électrique a été étudié. L'analyse structurale a montré que les films déposés ont cristallisé suivant la direction préférentielle (002) et que le dopage de l'aluminium avait un effet ...

  3. Optical tomography of tissues

    International Nuclear Information System (INIS)

    Zimnyakov, D A; Tuchin, Valerii V

    2002-01-01

    Methods of optical tomography of biological tissues are considered, which include pulse-modulation and frequency-modulation tomography, diffusion tomography with the use of cw radiation sources, optical coherent tomography, speckle-correlation tomography of nonstationary media, and optoacoustic tomography. The method for controlling the optical properties of tissues is studied from the point of view of increasing a probing depth in optical coherent tomography. The modern state and prospects of the development of optical tomography are discussed. (review)

  4. Three-dimensional in vivo fluorescence diffuse optical tomography of breast cancer in humans

    Science.gov (United States)

    Corlu, Alper; Choe, Regine; Durduran, Turgut; Rosen, Mark A.; Schweiger, Martin; Arridge, Simon R.; Schnall, Mitchell D.; Yodh, Arjun G.

    2007-05-01

    We present three-dimensional (3D) in vivo images of human breast cancer based on fluorescence diffuse optical tomography (FDOT). To our knowledge, this work represents the first reported 3D fluorescence tomography of human breast cancer in vivo. In our protocol, the fluorophore Indocyanine Green (ICG) is injected intravenously. Fluorescence excitation and detection are accomplished in the soft-compression, parallel-plane, transmission geometry using laser sources at 786 nm and spectrally filtered CCD detection. Phantom and in vivo studies confirm the signals are due to ICG fluorescence, rather than tissue autofluorescence and excitation light leakage. Fluorescence images of breast tumors were in good agreement with those of MRI, and with DOT based on endogenous contrast. Tumorto- normal tissue contrast based on ICG fluorescence was two-to-four-fold higher than contrast based on hemoglobin and scattering parameters. In total the measurements demonstrate that FDOT of breast cancer is feasible and promising.

  5. Prognostic impact of clinician-based interpretation of 18F-fluorodeoxyglucose positron emission tomography/computed tomography reports obtained in patients with newly diagnosed diffuse large B-cell lymphoma

    DEFF Research Database (Denmark)

    Mylam, Karen J; El-Galaly, Tarec C; Hutchings, Martin

    2014-01-01

    The aim of this study was to evaluate the prognostic value of clinician interpretation of positron emission tomography/computed tomography (PET/CT) reports at mid-therapy, interim PET (I-PET) and after the end of first-line therapy (E-PET) in patients with diffuse large B-cell lymphoma (DLBCL.......001) for positive, indeterminate and negative interpretation of PET/CT reports. Progression-free survival and OS did not differ significantly in patients with a negative and an indeterminate I-PET report. The use of well-defined reporting criteria, e.g. the Deauville five-point scale, is likely to reduce the number...

  6. Introduction aux lasers et à l'optique quantique

    CERN Document Server

    Grynberg, Gilbert; Fabre, Claude

    1997-01-01

    La plupart des ouvrages qui paraissent sur les lasers se divisent en deux catégories : d'une part, ceux qui traitent en détail de la description quantique des interactions matière-rayonnement ; d'autre part, ceux qui insistent sur telle ou telle caractéristique des sources laser et sur les problèmes nouveaux qu'elles permettent d'aborder, comme l'optique non-linéaire, la fusion inertielle ou le transfert d'information. Gilbert Grynberg, Alain Aspect et Claude Fabre ont fait le pari qu'il était possible de combiner ces deux points de vue dans un même ouvrage et de présenter à leurs lecteurs, à la fois les concepts quantiques de base qui permettent de comprendre l'absorption et l'émission de lumière par les atomes, et les principes de fonctionnement des lasers, leurs caractéristiques essentielles et quelques exemples importants d'applications concrètes. Ils ont, je crois, magnifiquement tenu leur pari.

  7. A combined reconstruction-classification method for diffuse optical tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hiltunen, P [Department of Biomedical Engineering and Computational Science, Helsinki University of Technology, PO Box 3310, FI-02015 TKK (Finland); Prince, S J D; Arridge, S [Department of Computer Science, University College London, Gower Street London, WC1E 6B (United Kingdom)], E-mail: petri.hiltunen@tkk.fi, E-mail: s.prince@cs.ucl.ac.uk, E-mail: s.arridge@cs.ucl.ac.uk

    2009-11-07

    We present a combined classification and reconstruction algorithm for diffuse optical tomography (DOT). DOT is a nonlinear ill-posed inverse problem. Therefore, some regularization is needed. We present a mixture of Gaussians prior, which regularizes the DOT reconstruction step. During each iteration, the parameters of a mixture model are estimated. These associate each reconstructed pixel with one of several classes based on the current estimate of the optical parameters. This classification is exploited to form a new prior distribution to regularize the reconstruction step and update the optical parameters. The algorithm can be described as an iteration between an optimization scheme with zeroth-order variable mean and variance Tikhonov regularization and an expectation-maximization scheme for estimation of the model parameters. We describe the algorithm in a general Bayesian framework. Results from simulated test cases and phantom measurements show that the algorithm enhances the contrast of the reconstructed images with good spatial accuracy. The probabilistic classifications of each image contain only a few misclassified pixels.

  8. Neutron penetrabilities using an optical model potential (1963); Penetrabilites des neutrons selon le modele du potentiel optique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Mani, G S; Melkanoff, M A; Iori, I [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The neutron penetrabilities and reaction cross-sections are presented in these tables for the case of an optical model potential for the nucleus, for nuclei up to mass 230. (authors) [French] Les penetrabilites et les sections efficaces de reaction pour les neutrons sont donnees dans ces tables en utilisant le modele du potentiel optique, pour les noyaux cibles jusqu'a la masse 230. (auteurs)

  9. Neutron penetrabilities using an optical model potential (1963); Penetrabilites des neutrons selon le modele du potentiel optique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Mani, G.S.; Melkanoff, M.A.; Iori, I. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The neutron penetrabilities and reaction cross-sections are presented in these tables for the case of an optical model potential for the nucleus, for nuclei up to mass 230. (authors) [French] Les penetrabilites et les sections efficaces de reaction pour les neutrons sont donnees dans ces tables en utilisant le modele du potentiel optique, pour les noyaux cibles jusqu'a la masse 230. (auteurs)

  10. Identification of prefrontal cortex (BA10) activation while performing Stroop test using diffuse optical tomography

    Science.gov (United States)

    Khadka, Sabin; Chityala, Srujan R.; Tian, Fenghua; Liu, Hanli

    2011-03-01

    Stroop test is commonly used as a behavior-testing tool for psychological examinations that are related to attention and cognitive control of the human brain. Studies have shown activations in Broadmann area 10 (BA10) of prefrontal cortex (PFC) during attention and cognitive process. The use of diffuse optical tomography (DOT) for human brain mapping is becoming more prevalent. In this study we expect to find neural correlates between the performed cognitive tasks and hemodynamic signals detected by a DOT system. Our initial observation showed activation of oxy-hemoglobin concentration in BA 10, which is consistent with some results seen by positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). Our study demonstrates the possibility of combining DOT with Stroop test to quantitatively investigate cognitive functions of the human brain at the prefrontal cortex.

  11. Singular value decomposition metrics show limitations of detector design in diffuse fluorescence tomography.

    Science.gov (United States)

    Leblond, Frederic; Tichauer, Kenneth M; Pogue, Brian W

    2010-11-29

    The spatial resolution and recovered contrast of images reconstructed from diffuse fluorescence tomography data are limited by the high scattering properties of light propagation in biological tissue. As a result, the image reconstruction process can be exceedingly vulnerable to inaccurate prior knowledge of tissue optical properties and stochastic noise. In light of these limitations, the optimal source-detector geometry for a fluorescence tomography system is non-trivial, requiring analytical methods to guide design. Analysis of the singular value decomposition of the matrix to be inverted for image reconstruction is one potential approach, providing key quantitative metrics, such as singular image mode spatial resolution and singular data mode frequency as a function of singular mode. In the present study, these metrics are used to analyze the effects of different sources of noise and model errors as related to image quality in the form of spatial resolution and contrast recovery. The image quality is demonstrated to be inherently noise-limited even when detection geometries were increased in complexity to allow maximal tissue sampling, suggesting that detection noise characteristics outweigh detection geometry for achieving optimal reconstructions.

  12. Diffuse Optical Tomography for Brain Imaging: Continuous Wave Instrumentation and Linear Analysis Methods

    Science.gov (United States)

    Giacometti, Paolo; Diamond, Solomon G.

    Diffuse optical tomography (DOT) is a functional brain imaging technique that measures cerebral blood oxygenation and blood volume changes. This technique is particularly useful in human neuroimaging measurements because of the coupling between neural and hemodynamic activity in the brain. DOT is a multichannel imaging extension of near-infrared spectroscopy (NIRS). NIRS uses laser sources and light detectors on the scalp to obtain noninvasive hemodynamic measurements from spectroscopic analysis of the remitted light. This review explains how NIRS data analysis is performed using a combination of the modified Beer-Lambert law (MBLL) and the diffusion approximation to the radiative transport equation (RTE). Laser diodes, photodiode detectors, and optical terminals that contact the scalp are the main components in most NIRS systems. Placing multiple sources and detectors over the surface of the scalp allows for tomographic reconstructions that extend the individual measurements of NIRS into DOT. Mathematically arranging the DOT measurements into a linear system of equations that can be inverted provides a way to obtain tomographic reconstructions of hemodynamics in the brain.

  13. Auscultation d'ouvrages avec un capteur géotextile à fibres optiques

    Directory of Open Access Journals (Sweden)

    ARTIERES, Olivier

    2012-08-01

    Full Text Available Pour évaluer la sécurité d'un ouvrage en terre, il est indispensable de disposer et de pouvoir interpréter des données d'auscultation, mais les mesures sont parfois difficiles à mettre en place et pas toujours fiables sur le long terme. Avec l’insertion de fibres optiques dans un géotextile, la solution TenCate GeoDetect® est le premier système d'auscultation conçu spécifiquement pour les applications géotechniques. Implantée depuis huit ans avec succès sur de nombreux ouvrages, elle permet d’accéder à des informations jusqu’ici très difficiles à obtenir et ceci avec une grande précision.

  14. Preclinical, fluorescence and diffuse optical tomography: non-contact instrumentation, modeling and time-resolved 3D reconstruction

    International Nuclear Information System (INIS)

    Nouizi, F.

    2011-09-01

    Time-Resolved Diffuse Optical Tomography (TR-DOT) is a new non-invasive imaging technique increasingly used in the clinical and preclinical fields. It yields optical absorption and scattering maps of the explored organs, and related physiological parameters. Time-Resolved Fluorescence Diffuse Optical Tomography (TR-FDOT) is based on the detection of fluorescence photons. It provides spatio-temporal maps of fluorescent probe concentrations and life times, and allows access to metabolic and molecular imaging which is important for diagnosis and therapeutic monitoring, particularly in oncology. The main goal of this thesis was to reconstruct 3D TR-DOT/TR-FDOT images of small animals using time-resolved optical technology. Data were acquired using optical fibers fixed around the animal without contact with its surface. The work was achieved in four steps: 1)- Setting up an imaging device to record the 3D coordinates of an animal's surface; 2)- Modeling the no-contact approach to solve the forward problem; 3)- Processing of the measured signals taking into account the impulse response of the device; 4)- Implementation of a new image reconstruction method based on a selection of carefully chosen points. As a result, good-quality 3D optical images were obtained owing to reduced cross-talk between absorption and scattering. Moreover, the computation time was cut down, compared to full-time methods using whole temporal profiles. (author)

  15. Contribution to the optical model study by the measurement of the reaction sections; Contribution au modele optique par la mesure de sections de reaction

    Energy Technology Data Exchange (ETDEWEB)

    Delaunay, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    Excitation functions of reaction cross-section {delta}{sub R} for protons were obtained between 5 and 11 MeV, for {sup 141}Pr and {sup 150}Nd by radioactive techniques and, between 9 and 12 MeV, for Cu and Ni by the transmission method. Results were compared to the prevision of the optical model. Calculations were made to see in what part {delta}{sub R} is able to reduce the ambiguities of the optical model. (author) [French] Des fonctions d'excitation de section efficace de reaction par protons {delta}{sub R} ont ete obtenues pour {sup 141}Pr et {sup 150}Nd, entre 5 et 11 MeV, par des methodes de radioactivite et pour Cu et Ni, entre 9 et 12 MeV, par la methode de transmission. Les resultats ont ete compares aux previsions du modele optique. Des calculs ont ete faits pour voir le role que peut jouer {delta}{sub R} pour diminuer les differentes ambiguites du modele optique. (auteur)

  16. CDMA à séquence directe appliqué aux systèmes de communications optiques

    OpenAIRE

    Lourdiane , Mounia

    2005-01-01

    Depuis quelques années, le besoin de systèmes de communications plus rapides et plus sures se fait sentir. Le partage entre utilisateurs de la très grande bande passante des fibres optiques nécessite des techniques d'accès adaptées. Afin de répondre à ces besoins, un certain nombre de techniques de multiplexage, dont le CDMA, ont été développées. Cette technique d'accès multiple est déjà largement utilisée dans les systèmes de communications radio-mobiles, que ce soit dans les normes américai...

  17. Validating atlas-guided DOT: a comparison of diffuse optical tomography informed by atlas and subject-specific anatomies.

    Science.gov (United States)

    Cooper, Robert J; Caffini, Matteo; Dubb, Jay; Fang, Qianqian; Custo, Anna; Tsuzuki, Daisuke; Fischl, Bruce; Wells, William; Dan, Ippeita; Boas, David A

    2012-09-01

    We describe the validation of an anatomical brain atlas approach to the analysis of diffuse optical tomography (DOT). Using MRI data from 32 subjects, we compare the diffuse optical images of simulated cortical activation reconstructed using a registered atlas with those obtained using a subject's true anatomy. The error in localization of the simulated cortical activations when using a registered atlas is due to a combination of imperfect registration, anatomical differences between atlas and subject anatomies and the localization error associated with diffuse optical image reconstruction. When using a subject-specific MRI, any localization error is due to diffuse optical image reconstruction only. In this study we determine that using a registered anatomical brain atlas results in an average localization error of approximately 18 mm in Euclidean space. The corresponding error when the subject's own MRI is employed is 9.1 mm. In general, the cost of using atlas-guided DOT in place of subject-specific MRI-guided DOT is a doubling of the localization error. Our results show that despite this increase in error, reasonable anatomical localization is achievable even in cases where the subject-specific anatomy is unavailable. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Noncontact 3-D Speckle Contrast Diffuse Correlation Tomography of Tissue Blood Flow Distribution.

    Science.gov (United States)

    Huang, Chong; Irwin, Daniel; Zhao, Mingjun; Shang, Yu; Agochukwu, Nneamaka; Wong, Lesley; Yu, Guoqiang

    2017-10-01

    Recent advancements in near-infrared diffuse correlation techniques and instrumentation have opened the path for versatile deep tissue microvasculature blood flow imaging systems. Despite this progress there remains a need for a completely noncontact, noninvasive device with high translatability from small/testing (animal) to large/target (human) subjects with trivial application on both. Accordingly, we discuss our newly developed setup which meets this demand, termed noncontact speckle contrast diffuse correlation tomography (nc_scDCT). The nc_scDCT provides fast, continuous, portable, noninvasive, and inexpensive acquisition of 3-D tomographic deep (up to 10 mm) tissue blood flow distributions with straightforward design and customization. The features presented include a finite-element-method implementation for incorporating complex tissue boundaries, fully noncontact hardware for avoiding tissue compression and interactions, rapid data collection with a diffuse speckle contrast method, reflectance-based design promoting experimental translation, extensibility to related techniques, and robust adjustable source and detector patterns and density for high resolution measurement with flexible regions of interest enabling unique application-specific setups. Validation is shown in the detection and characterization of both high and low contrasts in flow relative to the background using tissue phantoms with a pump-connected tube (high) and phantom spheres (low). Furthermore, in vivo validation of extracting spatiotemporal 3-D blood flow distributions and hyperemic response during forearm cuff occlusion is demonstrated. Finally, the success of instrument feasibility in clinical use is examined through the intraoperative imaging of mastectomy skin flap.

  19. Prediction of Central Nervous System Relapse of Diffuse Large B-Cell Lymphoma Using Pretherapeutic [18F]2-Fluoro-2-Deoxyglucose (FDG) Positron Emission Tomography/Computed Tomography.

    Science.gov (United States)

    Song, Yoo Sung; Lee, Won Woo; Lee, Jong Seok; Kim, Sang Eun

    2015-11-01

    Central nervous system (CNS) relapse of diffuse large B-cell lymphoma (DLBCL) is a rare complication, but has a poor prognosis with unknown pathophysiology. Recent trials of CNS prophylaxis have shown to be ineffective, despite patient's selection using several known clinical risk factors. In this study, the authors evaluated the value of pretreatment [F]2-Fluoro-2-deoxyglucose positron emission tomography in predicting CNS relapse in DLBCL patients.The authors analyzed 180 pathologically confirmed DLBCL patients, retrospectively. Patients underwent [F]2-Fluoro-2-deoxyglucose positron emission tomography/computed tomography before first line rituximab to cyclophosphamide, doxorubicin, vincristine, and prednisone therapy. Clinical characteristics were evaluated and total lesion glycolysis (TLG) with a threshold margin of 50% was calculated.Among age, sex, Ann Arbor stage, International Prognostic Index, revised International Prognostic Index, high serum lactate dehydrogenase level, presence of B symptoms, bulky disease (≥10 cm), extranodal lesion involvement, bone marrow involvement, high metabolic tumor volume ( >450 mL), and high TLG50 (>2000), the high TLG50 was the only significant prognostic factor for predicting CNS relapse in a multivariate analysis (P = 0.04). Kaplan-Meir survival analysis between high TLG50 (>2000) and low TLG50 (≤2000) groups revealed significantly different mean progression free survival (PFS) of 1317.2 ± 134.3 days and 1968.6 ± 18.3 days, respectively (P positron emission tomography/computed tomography is the most significant predictor of CNS relapse in un-treated DLBCL patients.

  20. Parallel Solver for Diffuse Optical Tomography on Realistic Head Models With Scattering and Clear Regions.

    Science.gov (United States)

    Placati, Silvio; Guermandi, Marco; Samore, Andrea; Scarselli, Eleonora Franchi; Guerrieri, Roberto

    2016-09-01

    Diffuse optical tomography is an imaging technique, based on evaluation of how light propagates within the human head to obtain the functional information about the brain. Precision in reconstructing such an optical properties map is highly affected by the accuracy of the light propagation model implemented, which needs to take into account the presence of clear and scattering tissues. We present a numerical solver based on the radiosity-diffusion model, integrating the anatomical information provided by a structural MRI. The solver is designed to run on parallel heterogeneous platforms based on multiple GPUs and CPUs. We demonstrate how the solver provides a 7 times speed-up over an isotropic-scattered parallel Monte Carlo engine based on a radiative transport equation for a domain composed of 2 million voxels, along with a significant improvement in accuracy. The speed-up greatly increases for larger domains, allowing us to compute the light distribution of a full human head ( ≈ 3 million voxels) in 116 s for the platform used.

  1. An efficient method for model refinement in diffuse optical tomography

    Science.gov (United States)

    Zirak, A. R.; Khademi, M.

    2007-11-01

    Diffuse optical tomography (DOT) is a non-linear, ill-posed, boundary value and optimization problem which necessitates regularization. Also, Bayesian methods are suitable owing to measurements data are sparse and correlated. In such problems which are solved with iterative methods, for stabilization and better convergence, the solution space must be small. These constraints subject to extensive and overdetermined system of equations which model retrieving criteria specially total least squares (TLS) must to refine model error. Using TLS is limited to linear systems which is not achievable when applying traditional Bayesian methods. This paper presents an efficient method for model refinement using regularized total least squares (RTLS) for treating on linearized DOT problem, having maximum a posteriori (MAP) estimator and Tikhonov regulator. This is done with combination Bayesian and regularization tools as preconditioner matrices, applying them to equations and then using RTLS to the resulting linear equations. The preconditioning matrixes are guided by patient specific information as well as a priori knowledge gained from the training set. Simulation results illustrate that proposed method improves the image reconstruction performance and localize the abnormally well.

  2. A comprehensive study of the use of temporal moments in time-resolved diffuse optical tomography: part I. Theoretical material

    Energy Technology Data Exchange (ETDEWEB)

    Ducros, Nicolas; Herve, Lionel; Dinten, Jean-Marc [CEA, LETI, MINATEC, 17 rue des Martyrs, F-38054 Grenoble (France); Da Silva, Anabela [Institut Fresnel, CNRS UMR 6133, Universite Aix-Marseille, Ecole Centrale Marseille, Campus universitaire de Saint-Jerome, F-13013 Marseille (France); Peyrin, Francoise [CREATIS, INSERM U 630, CNRS UMR 5220, Universite de Lyon, INSA de Lyon, bat. Blaise Pascal, F-69621 Villeurbanne Cedex (France)], E-mail: nicolas.ducros@cea.fr

    2009-12-07

    The problem of fluorescence diffuse optical tomography consists in localizing fluorescent markers from near-infrared light measurements. Among the different available acquisition modalities, the time-resolved modality is expected to provide measurements of richer information content. To extract this information, the moments of the time-resolved measurements are often considered. In this paper, a theoretical analysis of the moments of the forward problem in fluorescence diffuse optical tomography is proposed for the infinite medium geometry. The moments are expressed as a function of the source, detector and markers positions as well as the optical properties of the medium and markers. Here, for the first time, an analytical expression holding for any moments order is mathematically derived. In addition, analytical expressions of the mean, variance and covariance of the moments in the presence of noise are given. These expressions are used to demonstrate the increasing sensitivity of moments to noise. Finally, the newly derived expressions are illustrated by means of sensitivity maps. The physical interpretation of the analytical formulae in conjunction with their map representations could provide new insights into the analysis of the information content provided by moments.

  3. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Disseminated Cryptococcosis.

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography-computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm.

  4. Evaluation of diffuse thyroid diseases by computed tomography and 123I thyroidal uptake

    International Nuclear Information System (INIS)

    Kurihara, Yoshiko; Imanishi, Yoshimasa; Ehara, Norishige

    1991-01-01

    Understanding the iodine kinetics in the thyroid is useful for the diagnosis of a patient with diffuse thyroid disease. In this study, 9 controls and 50 patients with diffuse thyroid diseases, we evaluated diffuse thyroid diseases with 123 I thyroidal uptake and volume, iodine concentration, and net iodine content measured by computed tomography. There was no significant correlation between volume, iodine concentration, and net iodine content of the thyroid and 123 I thyroidal uptake. The thyroid volume in Graves' and Hashimoto's diseases was significantly larger than that in the control group. The thyroid iodine concentration in Graves' and Hashimoto's diseases was significantly smaller than that in the control group. The thyroid net iodine content in Hashimoto's disease was significantly smaller than that in the control group. Although most of the patients with Graves' disease had more increased radioiodine thyroidal uptake than the control group, there was no significant difference between them in the mean of the thyroid net iodine content. But the variance of net iodine contents in the former was significantly larger than that in the latter. The thyroid net iodine content was very low in all patients with very high thyroglobulin hemaggrugated antibody (TGHA) value although it was nearly normal in some patients with normal TGHA value. It was suggested that iodine concentration and net iodine content might be determined not only by iodine uptake but also by release and/or leakage of iodine compounds from the thyroid, which might depend on some antithyroid antibodies. (author)

  5. Imaging osteoarthritis in the knee joints using x-ray guided diffuse optical tomography

    Science.gov (United States)

    Zhang, Qizhi; Yuan, Zhen; Sobel, Eric S.; Jiang, Huabei

    2010-02-01

    In our previous studies, near-infrared (NIR) diffuse optical tomography (DOT) had been successfully applied to imaging osteoarthritis (OA) in the finger joints where significant difference in optical properties of the joint tissues was evident between healthy and OA finger joints. Here we report for the first time that large joints such as the knee can also be optically imaged especially when DOT is combined with x-ray tomosynthesis where the 3D image of the bones from x-ray is incorporated into the DOT reconstruction as spatial a priori structural information. This study demonstrates that NIR light can image large joints such as the knee in addition to finger joints, which will drastically broaden the clinical utility of our x-ray guided DOT technique for OA diagnosis.

  6. Visualisation of details of a complicated inner structure of model objects by the method of diffusion optical tomography

    International Nuclear Information System (INIS)

    Tret'yakov, Evgeniy V; Shuvalov, Vladimir V; Shutov, I V

    2002-01-01

    An approximate algorithm is tested for solving the problem of diffusion optical tomography in experiments on the visualisation of details of the inner structure of strongly scattering model objects containing scattering and semitransparent inclusions, as well as absorbing inclusions located inside other optical inhomogeneities. The stability of the algorithm to errors is demonstrated, which allows its use for a rapid (2 - 3 min) image reconstruction of the details of objects with a complicated inner structure. (laser biology and medicine)

  7. Ground-glass opacity in diffuse lung diseases: high-resolution computed tomography-pathology correlation

    International Nuclear Information System (INIS)

    Santos, Maria Lucia de Oliveira; Vianna, Alberto Domingues; Marchiori, Edson; Souza Junior, Arthur Soares; Moraes, Heleno Pinto de

    2003-01-01

    Ground-glass opacity is a finding frequently seen in high-resolution computed tomography examinations of the chest and is characterized by hazy increased attenuation of lung, however without blurring of bronchial and vascular margins. Due to its un specificity, association with other radiological, clinical and pathological findings must be considered for an accurate diagnostic interpretation. In this paper were reviewed 62 computed tomography examinations of patients with diffuse pulmonary diseases of 14 different etiologies in which ground-glass opacity was the only or the most remarkable finding, and correlated this findings with pathology abnormalities seen on specimens obtained from biopsies or necropsies. In pneumocystosis, ground-glass opacities correlated histologically with alveolar occupation by a foaming material containing parasites, in bronchiole alveolar cell carcinoma with thickening of the alveolar septa and occupation of the lumen by mucus and tumoral cells, in paracoccidioidomycosis with thickening of the alveolar septa, areas of fibrosis and alveolar bronchopneumonia exudate, in sarcoidosis with fibrosis or clustering of granulomas and in idiopathic pulmonary fibrosis with alveolar septa thickening due to fibrosis. Alveolar occupation by blood was found in cases of leptospirosis, idiopathic hemo siderosis, metastatic kidney tumor and invasive aspergillosis whereas oily vacuole were seen in lipoid pneumonia, proteinaceous and lipo proteinaceous material in silico proteinosis and pulmonary alveolar proteinosis, and edematous fluid in cardiac failure. (author)

  8. Frequency domain fluorescent diffuse tomography of small animals with DsRed2-expressed tumors

    Science.gov (United States)

    Turchin, Ilya V.; Savitsky, Alexander P.; Kamensky, Vladislav A.; Plehanov, Vladimir I.; Orlova, Anna G.; Sergeeva, Ekaterina A.; Kleshnin, Mikhail S.; Shirmanova, Marina V.

    2006-02-01

    The main applications of fluorescent proteins (FPs) are monitoring tumor growth, angiogenesis, metastases formation and effects of new classes of drugs. Different types of tomography allow fluorescence imaging of tumors located deep in human or animal tissue. These techniques were used for investigation of the distribution of near-infrared fluorescent probes, but only a few works are devoted to fluorescence tomography in visible light. In this work, preliminary results of the frequency domain fluorescent diffuse tomography (FD FDT) method in application to DsRed2 protein as a fluorescent agent are presented. For the first step of our experiments we utilized second harmonic generation of Nd:YAG laser (532 nm) modulated by low frequency (1 kHz) in the experimental setup. The transilluminative planar configuration was used in the setup. A series of model experiments has been conducted and show good agreement between theoretical and experimental fluorescence intensity. Post mortem experiments with capsules containing DsRed2 and scattering solution introduced into esophagus of rats to simulate tumor formation have been conducted. The results of these experiments show that sensitivity of the setup is sufficient to detect DsRed2 in concentrations similar to those in FP-expressed tumor, but the contrast is not enough high to separate fluorescence of DsRed2 and surrounding tissues. The setup can be significantly improved by utilizing high-frequency modulation (110 MHz using acousto-optical modulator) of the excitation light and precise phase measurements due to difference in fluorescence life-time of FPs and surrounding tissues. An algorithm of processing a fluorescent image based on calculating zero of maximum curvature was employed for detection of fluorescent inclusions boundaries in the image.

  9. Evaluation of diffuse thyroid diseases by computed tomography and sup 123 I thyroidal uptake

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, Yoshiko (Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine); Imanishi, Yoshimasa; Ehara, Norishige (and others)

    1991-10-01

    Understanding the iodine kinetics in the thyroid is useful for the diagnosis of a patient with diffuse thyroid disease. In this study, 9 controls and 50 patients with diffuse thyroid diseases, we evaluated diffuse thyroid diseases with {sup 123}I thyroidal uptake and volume, iodine concentration, and net iodine content measured by computed tomography. There was no significant correlation between volume, iodine concentration, and net iodine content of the thyroid and {sup 123}I thyroidal uptake. The thyroid volume in Graves' and Hashimoto's diseases was significantly larger than that in the control group. The thyroid iodine concentration in Graves' and Hashimoto's diseases was significantly smaller than that in the control group. The thyroid net iodine content in Hashimoto's disease was significantly smaller than that in the control group. Although most of the patients with Graves' disease had more increased radioiodine thyroidal uptake than the control group, there was no significant difference between them in the mean of the thyroid net iodine content. But the variance of net iodine contents in the former was significantly larger than that in the latter. The thyroid net iodine content was very low in all patients with very high thyroglobulin hemaggrugated antibody (TGHA) value although it was nearly normal in some patients with normal TGHA value. It was suggested that iodine concentration and net iodine content might be determined not only by iodine uptake but also by release and/or leakage of iodine compounds from the thyroid, which might depend on some antithyroid antibodies. (author).

  10. Dynamic studies of small animals with a four-color diffuse optical tomography imager

    International Nuclear Information System (INIS)

    Schmitz, Christoph H.; Graber, Harry L.; Pei Yaling; Farber, Mark; Stewart, Mark; Levina, Rita D.; Levin, Mikhail B.; Xu Yong; Barbour, Randall L.

    2005-01-01

    We present newly developed instrumentation for full-tomographic four-wavelength, continuous wave, diffuse optical tomography (DOT) imaging on small animals. A small-animal imaging stage was constructed, from materials compatible with in-magnet studies, which offers stereotaxic fixation of the animal and precise, stable probe positioning. Instrument performance, based on calibration and phantom studies, demonstrates excellent long-term signal stability. DOT measurements of the functional rat brain response to electric paw stimulation are presented, and these demonstrate high data quality and excellent sensitivity to hemodynamic changes. A general linear model analysis on individual trials is used to localize and quantify the occurrence of functional behavior associated with the different hemoglobin state responses. Statistical evaluation of outcomes of individual trials is employed to identify significant regional response variations for different stimulation sites. Image results reveal a diffuse cortical response and a strong reaction of the thalamus, both indicative of activation of pain pathways by the stimulation. In addition, a weaker lateralized functional component is observed in the brain response, suggesting presence of motor activation. An important outcome of the experiment is that it shows that reactions to individual provocations can be monitored, without having to resort to signal averaging. Thus the described technology may be useful for studies of long-term trends in hemodynamic response, as would occur, for example, in behavioral studies involving freely moving animals

  11. Toward real-time diffuse optical tomography: accelerating light propagation modeling employing parallel computing on GPU and CPU

    Science.gov (United States)

    Doulgerakis, Matthaios; Eggebrecht, Adam; Wojtkiewicz, Stanislaw; Culver, Joseph; Dehghani, Hamid

    2017-12-01

    Parameter recovery in diffuse optical tomography is a computationally expensive algorithm, especially when used for large and complex volumes, as in the case of human brain functional imaging. The modeling of light propagation, also known as the forward problem, is the computational bottleneck of the recovery algorithm, whereby the lack of a real-time solution is impeding practical and clinical applications. The objective of this work is the acceleration of the forward model, within a diffusion approximation-based finite-element modeling framework, employing parallelization to expedite the calculation of light propagation in realistic adult head models. The proposed methodology is applicable for modeling both continuous wave and frequency-domain systems with the results demonstrating a 10-fold speed increase when GPU architectures are available, while maintaining high accuracy. It is shown that, for a very high-resolution finite-element model of the adult human head with ˜600,000 nodes, consisting of heterogeneous layers, light propagation can be calculated at ˜0.25 s/excitation source.

  12. Gas diffusion, non-Darcy air permeability, and computed tomography images of a clay subsoil affected by compaction

    DEFF Research Database (Denmark)

    Schjønning, Per; Lamandé, Mathieu; Berisso, Feto Esimo

    2013-01-01

    Soil productivity and other soil functions are dependent on processes in the untilled subsoil. Undisturbed soil cores were collected at the 0.3- to 0.4-m depth from a heavy clay soil in Finland subjected to a single heavy traffic event by agricultural machinery three decades before sampling....... Untrafficked control plots were used as a reference. Computed tomography (CT) scanning was performed on soil cores at a field-sampled field capacity water content. Gas diffusion and air permeability were measured when the soil cores were drained to −1000 hPa matric potential (air permeability also at −100...... and −300 hPa). The air-filled pore space was measured with an air pycnometer and also calculated from mass balance and CT data. Gas diffusion and air permeability were also measured on a straight model tube and on autoclaved aerated concrete. The compaction treatment had not influenced soil total porosity...

  13. Investigation of detection limits for diffuse optical tomography systems: II. Analysis of slab and cup geometry for breast imaging.

    Science.gov (United States)

    Ziegler, Ronny; Brendel, Bernhard; Rinneberg, Herbert; Nielsen, Tim

    2009-01-21

    Using a statistical (chi-square) test on simulated data and a realistic noise model derived from the system's hardware we study the performance of diffuse optical tomography systems for fluorescence imaging. We compare the predicted smallest size of detectable lesions at various positions in slab and cup geometry and model how detection sensitivity depends on breast compression and lesion fluorescence contrast. Our investigation shows that lesion detection is limited by relative noise in slab geometry and by absolute noise in cup geometry.

  14. Adaptive weighted anisotropic diffusion for computed tomography denoising

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Zhi; Silver, Michael D. [Toshiba Medical Research Institute USA, Inc., Vernon Hills, IL (United States); Noshi, Yasuhiro [Toshiba Medical System Corporation, Tokyo (Japan)

    2011-07-01

    With increasing awareness of radiation safety, dose reduction has become an important task of modern CT system development. This paper proposes an adaptive weighted anisotropic diffusion method and an adaptive weighted sharp source anisotropic diffusion method as image domain filters to potentially help dose reduction. Different from existing anisotropic diffusion methods, the proposed methods incorporate an edge-sensitive adaptive source term as part of the diffusion iteration. It provides better edge and detail preservation. Visual evaluation showed that the new methods can reduce noise substantially without apparent edge and detail loss. The quantitative evaluations also showed over 50% of noise reduction in terms of noise standard deviations, which is equivalent to over 75% of dose reduction for a normal dose image quality. (orig.)

  15. Monitoring early tumor response to drug therapy with diffuse optical tomography

    Science.gov (United States)

    Flexman, Molly L.; Vlachos, Fotios; Kim, Hyun Keol; Sirsi, Shashank R.; Huang, Jianzhong; Hernandez, Sonia L.; Johung, Tessa B.; Gander, Jeffrey W.; Reichstein, Ari R.; Lampl, Brooke S.; Wang, Antai; Borden, Mark A.; Yamashiro, Darrell J.; Kandel, Jessica J.; Hielscher, Andreas H.

    2012-01-01

    Although anti-angiogenic agents have shown promise as cancer therapeutics, their efficacy varies between tumor types and individual patients. Providing patient-specific metrics through rapid noninvasive imaging can help tailor drug treatment by optimizing dosages, timing of drug cycles, and duration of therapy--thereby reducing toxicity and cost and improving patient outcome. Diffuse optical tomography (DOT) is a noninvasive three-dimensional imaging modality that has been shown to capture physiologic changes in tumors through visualization of oxygenated, deoxygenated, and total hemoglobin concentrations, using non-ionizing radiation with near-infrared light. We employed a small animal model to ascertain if tumor response to bevacizumab (BV), an anti-angiogenic agent that targets vascular endothelial growth factor (VEGF), could be detected at early time points using DOT. We detected a significant decrease in total hemoglobin levels as soon as one day after BV treatment in responder xenograft tumors (SK-NEP-1), but not in SK-NEP-1 control tumors or in non-responder control or BV-treated NGP tumors. These results are confirmed by magnetic resonance imaging T2 relaxometry and lectin perfusion studies. Noninvasive DOT imaging may allow for earlier and more effective control of anti-angiogenic therapy.

  16. Evaluation of diffuse large B-cell lymphoma patients with 64-slice multidetector computed tomography versus 18FDG positron emission tomography/computed tomography in initial staging and restaging after treatment.

    Science.gov (United States)

    Gómez León, Nieves; Vega, Gema; Rodríguez-Vigil Junco, Beatriz; Suevos Ballesteros, Carlos

    2018-04-25

    To prospectively compare the accuracy in initial staging and end-of-treatment restaging of diffuse large B-cell lymphoma (DLBCL) between 64-slice multidetector computed tomography (64MDCT) and 18FDG positron emission tomography/computed tomography (18FGD PET/CT) with intravenous contrast injection. Randomised and blind controlled clinical multicentric trial that included biopsy-proven DLBCL patients. Seventy-two patients from five different hospitals in the region of Madrid, Spain, were enrolled in the study between January 2012 and June 2015. Thirty-six were randomly allocated to 18FDG PET/TC and the other 36 to 64MDCT for initial staging and end-of-treatment restaging. A nuclear medicine physician and a radiologist independently analysed 18FDG PET/TC images and reached an agreement post-hoc. 64MDCT images were separately evaluated by a different radiologist. Every set of images was compared to the reference standard that included clinical data, complementary tests and follow-up. The study was approved by participating centres' ethics committees and written informed consent was obtained from all the participants. A good agreement was observed between both diagnostic techniques and the reference standard in initial staging [18FDG PET/CT (k=0.5) and 64MDCT (k=0.6)], although only the 18FDG PET/TC showed a good agreement with the reference standard for the end-of-treatment restaging (k=0.7). In DLBCL, both 18FDG PET/TC and 64MDCT have shown good agreement with the reference standard in initial staging. Nevertheless, 18FDG PET/CT has shown to be superior to 64MDCT in end-of-treatment response assessment. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  17. Diffuse lung neoplasms. Correlation between high resolution computerized tomography and anatomopathology; Neoplasias pulmonares difusas: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Irion, Klaus L. [Complexo Hospitalar Santa Casa de Porto Alegre, RS (Brazil). Servico de Radiologia do Pavilhao Pereira Filho; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto, SP (Brazil)]. E-mail: edmarchiori@zipmail.com.br

    2002-08-01

    A short comparative evaluation study between high resolution computerized tomography and anatomopathologic findings is presented. The association of these two diagnostic techniques is discussed as a factor to enhance the accuracy of diffuse lung diseases, such as carcinomatous lymphangitis, Kaposi's Sarcoma, lymphomas, hematogenic metastases, bronchiole-alveolar carcinoma and leukemia. (MAC)

  18. A time-domain fluorescence diffusion optical tomography system for breast tumor diagnosis

    Science.gov (United States)

    Zhang, Wei; Gao, Feng; Wu, LinHui; Ma, Wenjuan; Yang, Fang; Zhou, Zhongxing; Zhang, Limin; Zhao, Huijuan

    2011-02-01

    A prototype time-domain fluorescence diffusion optical tomography (FDOT) system using near-infrared light is presented. The system employs two pulsed light sources, 32 source fibers and 32 detection channels, working separately for acquiring the temporal distribution of the photon flux on the tissue surface. The light sources are provided by low power picosecond pulsed diode lasers at wavelengths of 780 nm and 830 nm, and a 1×32-fiber-optic-switch sequentially directs light sources to the object surface through 32 source fibers. The light signals re-emitted from the object are collected by 32 detection fibers connected to four 8×1 fiber-optic-switch and then routed to four time-resolved measuring channels, each of which consists of a collimator, a filter wheel, a photomultiplier tube (PMT) photon-counting head and a time-correlated single photon counting (TCSPC) channel. The performance and efficacy of the designed multi-channel PMT-TCSPC system are assessed by reconstructing the fluorescent yield and lifetime images of a solid phantom.

  19. Highly-sensitive and large-dynamic diffuse optical tomography system for breast tumor detection

    Science.gov (United States)

    Du, Wenwen; Zhang, Limin; Yin, Guoyan; Zhang, Yanqi; Zhao, Huijuan; Gao, Feng

    2018-02-01

    Diffuse optical tomography (DOT) as a new functional imaging has important clinical applications in many aspects such as benign and malignant breast tumor detection, tumor staging and so on. For quantitative detection of breast tumor, a three-wavelength continuous-wave DOT prototype system combined the ultra-high sensitivity of the photon-counting detection and the measurement parallelism of the lock-in technique was developed to provide high temporal resolution, high sensitivity, large dynamic detection range and signal-to-noise ratio. Additionally, a CT-analogous scanning mode was proposed to cost-effectively increase the detection data. To evaluate the feasibility of the system, a series of assessments were conducted. The results demonstrate that the system can obtain high linearity, stability and negligible inter-wavelength crosstalk. The preliminary phantom experiments show the absorption coefficient is able to be successfully reconstructed, indicating that the system is one of the ideal platforms for optical breast tumor detection.

  20. Modeling bioluminescent photon transport in tissue based on Radiosity-diffusion model

    Science.gov (United States)

    Sun, Li; Wang, Pu; Tian, Jie; Zhang, Bo; Han, Dong; Yang, Xin

    2010-03-01

    Bioluminescence tomography (BLT) is one of the most important non-invasive optical molecular imaging modalities. The model for the bioluminescent photon propagation plays a significant role in the bioluminescence tomography study. Due to the high computational efficiency, diffusion approximation (DA) is generally applied in the bioluminescence tomography. But the diffusion equation is valid only in highly scattering and weakly absorbing regions and fails in non-scattering or low-scattering tissues, such as a cyst in the breast, the cerebrospinal fluid (CSF) layer of the brain and synovial fluid layer in the joints. A hybrid Radiosity-diffusion model is proposed for dealing with the non-scattering regions within diffusing domains in this paper. This hybrid method incorporates a priori information of the geometry of non-scattering regions, which can be acquired by magnetic resonance imaging (MRI) or x-ray computed tomography (CT). Then the model is implemented using a finite element method (FEM) to ensure the high computational efficiency. Finally, we demonstrate that the method is comparable with Mont Carlo (MC) method which is regarded as a 'gold standard' for photon transportation simulation.

  1. Tomography in nuclear medicine

    International Nuclear Information System (INIS)

    Levi de Cabrejas, Mariana

    1999-01-01

    This book is a contribution to the training and diffusion of the tomography method image diagnosis in nuclear medicine, which principal purpose is the information to professionals and technical personnel, specially for the spanish speaking staff

  2. Contrast improvement of continuous wave diffuse optical tomography reconstruction by hybrid approach using least square and genetic algorithm

    Science.gov (United States)

    Patra, Rusha; Dutta, Pranab K.

    2015-07-01

    Reconstruction of the absorption coefficient of tissue with good contrast is of key importance in functional diffuse optical imaging. A hybrid approach using model-based iterative image reconstruction and a genetic algorithm is proposed to enhance the contrast of the reconstructed image. The proposed method yields an observed contrast of 98.4%, mean square error of 0.638×10-3, and object centroid error of (0.001 to 0.22) mm. Experimental validation of the proposed method has also been provided with tissue-like phantoms which shows a significant improvement in image quality and thus establishes the potential of the method for functional diffuse optical tomography reconstruction with continuous wave setup. A case study of finger joint imaging is illustrated as well to show the prospect of the proposed method in clinical diagnosis. The method can also be applied to the concentration measurement of a region of interest in a turbid medium.

  3. Proprietes optiques dans l'infrarouge lointain et de transport electrique de systemes electroniques a basse dimensionalite

    Science.gov (United States)

    Lefebvre, Jacques

    Cette these presente une etude experimentale de deux systemes ayant des proprietes physiques particulieres decoulant de leur caractere anisotrope. Le premier systeme est un conducteur organique quasi-unidimensionnel, le sel de Bechgaard (TMTSF)sb2ClOsb4. Le second est un systeme mesoscopique base sur une heterostructure a base de GaAs/Alsb{x}Gasb{1-x}As pour lequel la dimensionalite peut etre variee continuement entre deux et un. En dimension un, ce systeme porte le nom de fil quantique. Pour le sel de Bechgaard (TMTSF)sb2ClOsb4, une mesure de la photoconductivite dans l'infrarouge lointain a permis d'identifier une resonance dans la phase onde de densite de spin sous champ magnetique (ou ODSIC). Cette resonance, visible dans la gamme de longueurs d'onde entre 410 et 599 mum, se deplace vers les forts champs magnetiques avec l'augmentation de l'energie du photon. Malgre qu'elle s'apparente a une resonance cyclotron, un calcul theorique du coefficient d'absorption a montre qu'elle est intimement liee a la phase ODSIC et que son energie est donnee par sqrt{4deltasbsp{N}{2}+omegasbsp{c}{2}} avec deltasb{N}, l'amplitude de la bande interdite ODSIC au niveau de Fermi et omegasb{c}, l'energie cyclotron. Le gaz d'electrons dans une heterostructure a base de GaAs/Alsb{x}Gasb{1-x}As a ete etudie dans les regimes dimensionnels entre deux et un (de 2D a quasi-1D en passant par quasi-2D). En combinant des mesures de transport electrique a des mesures de transmission optique dans l'infrarouge lointain obtenues quasi-simultanement sur un meme echantillon, plusieurs conclusions emergent. Entre autres, trois regimes de modulation sont identifies et a leurs frontieres, des signes distinctifs apparaissent autant dans les mesures de transport que dans les mesures de la transmission optique. Une analyse globale permet de degager une vue coherente des modes collectifs dans les differents regimes dimensionnels.

  4. Study of the neutron strength function and of the diffusion radius as a function of mass number; Etude de la fonction densite de neutron et du rayon de diffusion en fonction du nombre de masse

    Energy Technology Data Exchange (ETDEWEB)

    Morgenstern, J [Commissariat a l' Energie Atomique, 91 - Saclay (France). Centre d' Etudes Nucleaires

    1968-09-01

    The strength functions S{sub 0} and S{sub 1}, and the scattering length R' are studied. The values of S{sub 0}, S{sub 1} and R' are obtained by shape analysis of the individual resonances observed in total neutron cross-section measurements. These measurements were performed at the Saclay 45 MeV linac by the time of flight method. The best resolution achieved was equal to 0.19 ns/m. We have particularly studied the nuclei around number of mass A = 50, 90, 140 and 200. The experimental values of S{sub 0}, S{sub 1} and R' are compared with optical model calculations. A fairly good agreement is obtained using an optical potential with surface absorption. (author) [French] Nous etudions les fonctions densite S{sub 0} et S{sub 1} ainsi que le rayon de diffusion R'. Les valeurs de S{sub 0}, S{sub 1} et R' sont determinees a partir de l'analyse de forme des resonances individuelles observees lors de la mesure de la section efficace neutronique totale. Cette mesure a ete faite aupres de l'accelerateur lineaire d'electrons de 45 MeV de Saclay par la methode du temps de vol. La meilleure resolution atteinte etait egale a 0.19 ns/m. Nous avons particulierement etudie les noyaux situes vers les nombres de masse A 50, 90, 140 et 200. Nous comparons ensuite les valeurs experimentales de S{sub 0}, S{sub 1} et R' a differents calculs de modele optique. Un bon accord est obtenu avec un potentiel optique a absorption de surface. (auteur)

  5. Toward real-time diffuse optical tomography: accelerating light propagation modeling employing parallel computing on GPU and CPU.

    Science.gov (United States)

    Doulgerakis, Matthaios; Eggebrecht, Adam; Wojtkiewicz, Stanislaw; Culver, Joseph; Dehghani, Hamid

    2017-12-01

    Parameter recovery in diffuse optical tomography is a computationally expensive algorithm, especially when used for large and complex volumes, as in the case of human brain functional imaging. The modeling of light propagation, also known as the forward problem, is the computational bottleneck of the recovery algorithm, whereby the lack of a real-time solution is impeding practical and clinical applications. The objective of this work is the acceleration of the forward model, within a diffusion approximation-based finite-element modeling framework, employing parallelization to expedite the calculation of light propagation in realistic adult head models. The proposed methodology is applicable for modeling both continuous wave and frequency-domain systems with the results demonstrating a 10-fold speed increase when GPU architectures are available, while maintaining high accuracy. It is shown that, for a very high-resolution finite-element model of the adult human head with ∼600,000 nodes, consisting of heterogeneous layers, light propagation can be calculated at ∼0.25  s/excitation source. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  6. Heterodyne frequency-domain multispectral diffuse optical tomography of breast cancer in the parallel-plane transmission geometry

    Energy Technology Data Exchange (ETDEWEB)

    Ban, H. Y.; Kavuri, V. C., E-mail: venk@physics.upenn.edu; Cochran, J. M.; Pathak, S.; Chung, S. H.; Yodh, A. G. [Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Schweiger, M.; Arridge, S. R. [Department of Computer Science, University College London, London WC1E 7JE (United Kingdom); Xie, L. [Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Busch, D. R. [Division of Neurology, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania 19104 (United States); Katrašnik, J. [Faculty of Electrical Engineering, University of Ljubljana, Ljubljana 1000 (Slovenia); Lee, K. [Daegu Gyeongbuk Institute of Science and Technology, Daegu 711-813 (Korea, Republic of); Choe, R. [Department of Biomedical Engineering, University of Rochester, Rochester, New York 14642 (United States); Czerniecki, B. J. [Department of Surgery, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States)

    2016-07-15

    Purpose: The authors introduce a state-of-the-art all-optical clinical diffuse optical tomography (DOT) imaging instrument which collects spatially dense, multispectral, frequency-domain breast data in the parallel-plate geometry. Methods: The instrument utilizes a CCD-based heterodyne detection scheme that permits massively parallel detection of diffuse photon density wave amplitude and phase for a large number of source–detector pairs (10{sup 6}). The stand-alone clinical DOT instrument thus offers high spatial resolution with reduced crosstalk between absorption and scattering. Other novel features include a fringe profilometry system for breast boundary segmentation, real-time data normalization, and a patient bed design which permits both axial and sagittal breast measurements. Results: The authors validated the instrument using tissue simulating phantoms with two different chromophore-containing targets and one scattering target. The authors also demonstrated the instrument in a case study breast cancer patient; the reconstructed 3D image of endogenous chromophores and scattering gave tumor localization in agreement with MRI. Conclusions: Imaging with a novel parallel-plate DOT breast imager that employs highly parallel, high-resolution CCD detection in the frequency-domain was demonstrated.

  7. Diffuse correlation tomography in the transport regime: A theoretical study of the sensitivity to Brownian motion

    Science.gov (United States)

    Tricoli, Ugo; Macdonald, Callum M.; Durduran, Turgut; Da Silva, Anabela; Markel, Vadim A.

    2018-02-01

    Diffuse correlation tomography (DCT) uses the electric-field temporal autocorrelation function to measure the mean-square displacement of light-scattering particles in a turbid medium over a given exposure time. The movement of blood particles is here estimated through a Brownian-motion-like model in contrast to ordered motion as in blood flow. The sensitivity kernel relating the measurable field correlation function to the mean-square displacement of the particles can be derived by applying a perturbative analysis to the correlation transport equation (CTE). We derive an analytical expression for the CTE sensitivity kernel in terms of the Green's function of the radiative transport equation, which describes the propagation of the intensity. We then evaluate the kernel numerically. The simulations demonstrate that, in the transport regime, the sensitivity kernel provides sharper spatial information about the medium as compared with the correlation diffusion approximation. Also, the use of the CTE allows one to explore some additional degrees of freedom in the data such as the collimation direction of sources and detectors. Our results can be used to improve the spatial resolution of DCT, in particular, with applications to blood flow imaging in regions where the Brownian motion is dominant.

  8. Optics of a double focussing magnetic sector by fringe effect (1960); Optique d'un secteur magnetique a double focalisation par effet de franges (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Krafft, J [Commissariat a l' Energie Atomique, Lab. de Physique Nucleaire, Grenoble (France). Centre d' Etudes Nucleaires; [Grenoble-1 Univ., 38 (France); [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1960-07-01

    General study of the optical elements of a double focussing magnetic selector by fringe effect, with a view to its application to the monochromatization of the proton, deuteron or triton beam of the 1.4 MeV accelerator. (author) [French] Etude generale des elements optiques d'un selecteur magnetique a double focalisation par effet de franges, en vue de l'application a la monochromation du faisceau de protons, deutons ou tritons de l'accelerateur 1,4 MeV. (auteur)

  9. Diffuse optical tomography with structured-light patterns to quantify breast density

    Science.gov (United States)

    Kwong, Jessica; Nouizi, Farouk; Cho, Jaedu; Zheng, Jie; Li, Yifan; Chen, Jeon-hor; Su, Min-Ying; Gulsen, Gultekin

    2016-02-01

    Breast density is an independent risk factor for breast cancer, where women with denser breasts are more likely to develop cancer. By identifying women at higher risk, healthcare providers can suggest screening at a younger age to effectively diagnose and treat breast cancer in its earlier stages. Clinical risk assessment models currently do not incorporate breast density, despite its strong correlation with breast cancer. Current methods to measure breast density rely on mammography and MRI, both of which may be difficult to use as a routine risk assessment tool. We propose to use diffuse optical tomography with structured-light to measure the dense, fibroglandular (FGT) tissue volume, which has a different chromophore signature than the surrounding adipose tissue. To test the ability of this technique, we performed simulations by creating numerical breast phantoms from segmented breast MR images. We looked at two different cases, one with a centralized FGT distribution and one with a dispersed distribution. As expected, the water and lipid volumes segmented at half-maximum were overestimated for the dispersed case. However, it was noticed that the recovered water and lipid concentrations were lower and higher, respectively, than the centralized case. This information may provide insight into the morphological distribution of the FGT and can be a correction in estimating the breast density.

  10. Direct imaging of thermally-activated grain-boundary diffusion in Cu/Co/IrMn/Pt exchange-bias structures using atom-probe tomography

    Energy Technology Data Exchange (ETDEWEB)

    Letellier, F.; Lardé, R.; Le Breton, J.-M., E-mail: jean-marie.lebreton@univ-rouen.fr [Groupe de Physique des Matériaux, UMR 6634 CNRS/Université et INSA de Rouen, F-76801 Saint Etienne du Rouvray (France); Lechevallier, L. [Groupe de Physique des Matériaux, UMR 6634 CNRS/Université et INSA de Rouen, F-76801 Saint Etienne du Rouvray (France); Département de GEII, Université de Cergy-Pontoise, F-95031 Cergy-Pontoise (France); Akmaldinov, K. [SPINTEC, Univ. Grenoble-Alpes/CNRS/INAC-CEA, F-38000 Grenoble (France); CROCUS Technology, F-38025 Grenoble (France); Auffret, S.; Dieny, B.; Baltz, V., E-mail: vincent.baltz@cea.fr [SPINTEC, Univ. Grenoble-Alpes/CNRS/INAC-CEA, F-38000 Grenoble (France)

    2014-11-28

    Magnetic devices are often subject to thermal processing steps, such as field cooling to set exchange bias and annealing to crystallize amorphous magnetic electrodes. These processing steps may result in interdiffusion and the subsequent deterioration of magnetic properties. In this study, we investigated thermally-activated diffusion in Cu/Co/IrMn/Pt exchange biased polycrystalline thin-film structures using atom probe tomography. Images taken after annealing at 400 °C for 60 min revealed Mn diffusion into Co grains at the Co/IrMn interface and along Pt grain boundaries for the IrMn/Pt stack, i.e., a Harrison type C regime. Annealing at 500 °C showed further Mn diffusion into Co grains. At the IrMn/Pt interface, annealing at 500 °C led to a type B behavior since Mn diffusion was detected both along Pt grain boundaries and also into Pt grains. The deterioration of the films' exchange bias properties upon annealing was correlated to the observed diffusion. In particular, the topmost Pt capping layer thickness turned out to be crucial since a faster deterioration of the exchange bias properties for thicker caps was observed. This is consistent with the idea that Pt acts as a getter for Mn, drawing Mn out of the IrMn layer.

  11. Computerized tomography and pulmonary diffusing capacity in highly trained athletes after performing a triathlon.

    Science.gov (United States)

    Caillaud, C; Serre-Cousiné, O; Anselme, F; Capdevilla, X; Préfaut, C

    1995-10-01

    We investigated the computerized tomographies (CTs) of the thorax and the pulmonary diffusing capacity for CO (DLCO) in eight male athletes before and after a triathlon. DLCO and alveolar volume (VA) were simultaneously measured during 9 s of breath holding. The transfer coefficient (KCO = DLCO/VA) was then calculated. CT scanning was performed during breath holding with the subjects in the supine position. Scanner analysis was done by 1) counting the linear and polygonal opacities (index of interstitial fluid accumulation) and 2) calculating the physical mean lung density and the mean slice mass. Results showed a significant reduction in DLCO (44.9 +/- 2.3 vs. 42.9 +/- 1.7 ml.min-1.mmHg-1; P triathlon and an increase in mean lung density (0.21 +/- 0.009 vs. 0.25 +/- 0.01 g/cm3; P long-distance race and showed a concomitant increase in CT lung density and in the number of opacities.

  12. Artifact reduction method in ultrasound-guided diffuse optical tomography using exogenous contrast agents

    Science.gov (United States)

    Ardeshirpour, Yasaman; Biswal, Nrusingh; Aguirre, Andres; Zhu, Quing

    2011-04-01

    In diffuse optical tomography (DOT), a typical perturbation approach requires two sets of measurements obtained at the lesion breast (lesion or target site) and a contra-lateral location of the normal breast (reference site) for image reconstruction. For patients who have a small amount of breast tissue, the chest-wall underneath the breast tissue at both sites affects the imaging results. In this group of patients, the perturbation, which is the difference between measurements obtained at the lesion and reference sites, may include the information of background mismatch which can generate artifacts or affect the reconstructed quantitative absorption coefficient of the lesion. Also, for patients who have a single breast due to prior surgery, the contra-lateral reference is not available. To improve the DOT performance or overcome its limitation, we introduced a new method based on an exogenous contrast agent and demonstrate its performance using animal models. Co-registered ultrasound was used to guide the lesion localization. The results have shown that artifacts caused by background mismatch can be reduced significantly by using this new method.

  13. Utility of fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography in a child with chronic granulomatous disease

    International Nuclear Information System (INIS)

    Garg, Gunjan; DaSilva, Raphaella; Bhalakia, Avni; Milstein, David M.

    2016-01-01

    We report the fluorodeoxyglucose positron emission tomography/computed tomography (FDG - PET/CT) findings in an 11-month-old boy with suspected milk protein allergy, presented to the hospital with 2-month history of fever of unknown origin and failure to thrive. It showed FDG avid lymphadenopathy above and below the diaphragm and splenic focus, which could represent diffuse inflammatory process or lymphoma. Subsequent jejunal biopsy showed non-necrotizing granulomas

  14. Parallel, Rapid Diffuse Optical Tomography of Breast

    National Research Council Canada - National Science Library

    Yodh, Arjun

    2001-01-01

    During the last year we have experimentally and computationally investigated rapid acquisition and analysis of informationally dense diffuse optical data sets in the parallel plate compressed breast geometry...

  15. Parallel, Rapid Diffuse Optical Tomography of Breast

    National Research Council Canada - National Science Library

    Yodh, Arjun

    2002-01-01

    During the last year we have experimentally and computationally investigated rapid acquisition and analysis of informationally dense diffuse optical data sets in the parallel plate compressed breast geometry...

  16. Effects of polytetrafluoroethylene treatment and compression on gas diffusion layer microstructure using high-resolution X-ray computed tomography

    Science.gov (United States)

    Khajeh-Hosseini-Dalasm, Navvab; Sasabe, Takashi; Tokumasu, Takashi; Pasaogullari, Ugur

    2014-11-01

    The microstructure of a TGP-H-120 Toray paper gas diffusion layer (GDL) was investigated using high resolution X-ray computed tomography (CT) technique, with a resolution of 1.8 μm and a field of view (FOV) of ∼1.8 × 1.8 mm. The images obtained from the tomography scans were further post processed, and image thresholding and binarization methodologies are presented. The validity of Otsu's thresholding method was examined. Detailed information on bulk porosity and porosity distribution of the GDL at various Polytetrafluoroethylene (PTFE) treatments and uniform/non-uniform compression pressures was provided. A sample holder was designed to investigate the effects of non-uniform compression pressure, which enabled regulating compression pressure between 0, and 3 MPa at a gas channel/current collector rib configuration. The results show the heterogeneous and anisotropic microstructure of the GDL, non-uniform distribution of PTFE, and significant microstructural change under uniform/non-uniform compression. These findings provide useful inputs for numerical models to include the effects of microstructural changes in the study of transport phenomena within the GDL and to increase the accuracy and predictability of cell performance.

  17. Study of the neutron strength function and of the diffusion radius as a function of mass number; Etude de la fonction densite de neutron et du rayon de diffusion en fonction du nombre de masse

    Energy Technology Data Exchange (ETDEWEB)

    Morgenstern, J. [Commissariat a l' Energie Atomique, 91 - Saclay (France). Centre d' Etudes Nucleaires

    1968-09-01

    The strength functions S{sub 0} and S{sub 1}, and the scattering length R' are studied. The values of S{sub 0}, S{sub 1} and R' are obtained by shape analysis of the individual resonances observed in total neutron cross-section measurements. These measurements were performed at the Saclay 45 MeV linac by the time of flight method. The best resolution achieved was equal to 0.19 ns/m. We have particularly studied the nuclei around number of mass A = 50, 90, 140 and 200. The experimental values of S{sub 0}, S{sub 1} and R' are compared with optical model calculations. A fairly good agreement is obtained using an optical potential with surface absorption. (author) [French] Nous etudions les fonctions densite S{sub 0} et S{sub 1} ainsi que le rayon de diffusion R'. Les valeurs de S{sub 0}, S{sub 1} et R' sont determinees a partir de l'analyse de forme des resonances individuelles observees lors de la mesure de la section efficace neutronique totale. Cette mesure a ete faite aupres de l'accelerateur lineaire d'electrons de 45 MeV de Saclay par la methode du temps de vol. La meilleure resolution atteinte etait egale a 0.19 ns/m. Nous avons particulierement etudie les noyaux situes vers les nombres de masse A 50, 90, 140 et 200. Nous comparons ensuite les valeurs experimentales de S{sub 0}, S{sub 1} et R' a differents calculs de modele optique. Un bon accord est obtenu avec un potentiel optique a absorption de surface. (auteur)

  18. Significance of a postenhancement computed tomography findings in liver cirrhosis: In view of hemodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Suck Hong; Kim, Byung Soo [Pusan National University College of Medicine, Pusan (Korea, Republic of)

    1985-04-15

    We observed a significant sign in postenhancement computed tomography of liver cirrhosis, that is visualization of portal venous branches. During postenhancement computed tomography scanning of liver, the portal vein can not be identified in liver parenchyme in 84% of patients without known cirrhosis (including chronic active hepatitis). The two have the same hemodynamic changes in that there is diffuse fibrosis and resultant decrease in vascular bed. Visualization of intrahepatic portal branches in postenhancement computed tomography is because of decreased diffusion ability and portal hypertension.

  19. Improving CT-guided transthoracic biopsy of mediastinal lesions by diffusion-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcos Duarte; TyngI, Chiang Cheng; Bitencourt, Almir Galvao Vieira; Gross, Jefferson Luiz; Zurstrassen, Charles Edouard, E-mail: marcosduarte500@gmail.com [AC Camargo Cancer Center, Sao Paulo, SP (Brazil); Hochhegger, Bruno [Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), RS (Brazil). Dept. de Radiologia; Benveniste, Marcelo Felipe Kuperman; Odisio, Bruno Calazans [University of Texas, MD Anderson Cancer Center, Houston, TX (United States); Marchiori, Edson [Universidade Federal do Rio de Janeiro (UFRJ), Petropolis, RJ (Brazil)

    2014-11-15

    Objectives: to evaluate the preliminary results obtained using diffusion-weighted magnetic resonance imaging and the apparent diffusion coefficient for planning computed tomography-guided biopsies of selected mediastinal lesions. Methods: eight patients with mediastinal lesions suspicious for malignancy were referred for computed tomography-guided biopsy. Diffusion-weighted magnetic resonance imaging and apparent diffusion coefficient measurement were performed to assist in biopsy planning with diffusion/computed tomography fused images. We selected mediastinal lesions that could provide discordant diagnoses depending on the biopsy site, including large heterogeneous masses, lesions associated with lung atelectasis or consolidation, lesions involving large mediastinal vessels and lesions for which the results of biopsy using other methods and histopathological examination were divergent from the clinical and radiological suspicion. Results: in all cases, the biopsy needle was successfully directed to areas of higher signal intensity on diffusion weighted sequences and the lowest apparent diffusion coefficient within the lesion (mean, 0.8 [range, 0.6–1.1]610{sup -3} mm{sup 2}/s), suggesting high cellularity. All biopsies provided adequate material for specific histopathological diagnoses of four lymphomas, two sarcomas and two thymoma s. Conclusion: functional imaging tools, such as diffusion-weighted imaging and the apparent diffusion coefficient, are promising for implementation in noninvasive and imaging-guided procedures. However, additional studies are needed to confirm that mediastinal biopsy can be improved with these techniques. (author)

  20. High resolution CT in diffuse lung disease

    International Nuclear Information System (INIS)

    Webb, W.R.

    1995-01-01

    High resolution CT (computerized tomography) was discussed in detail. The conclusions were HRCT is able to define lung anatomy at the secondary lobular level and define a variety of abnormalities in patients with diffuse lung diseases. Evidence from numerous studies indicates that HRCT can play a major role in the assessment of diffuse infiltrative lung disease and is indicate clinically (95 refs.)

  1. High resolution CT in diffuse lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Webb, W R [California Univ., San Francisco, CA (United States). Dept. of Radiology

    1996-12-31

    High resolution CT (computerized tomography) was discussed in detail. The conclusions were HRCT is able to define lung anatomy at the secondary lobular level and define a variety of abnormalities in patients with diffuse lung diseases. Evidence from numerous studies indicates that HRCT can play a major role in the assessment of diffuse infiltrative lung disease and is indicate clinically (95 refs.).

  2. Does the intensity of diffuse thyroid gland uptake on F-18 fluorodeoxyglucose positron emission tomography/computed tomography scan predict the severity of hypothyroidism? Correlation between maximal standardized uptake value and serum thyroid stimulating hormone levels

    International Nuclear Information System (INIS)

    Pruthi, Ankur; Choudhury, Partha Sarathi; Gupta, Manoj; Taywade, Sameer

    2015-01-01

    F-18 fluorodeoxyglucose (F-18 FDG) positron emission tomography/computed tomography (PET/CT) scan and hypothyroidism. The aim was to determine whether the intensity of diffuse thyroid gland uptake on F-18 FDG PET/CT scans predicts the severity of hypothyroidism. A retrospective analysis of 3868 patients who underwent F-18 FDG PET/CT scans, between October 2012 and June 2013 in our institution for various oncological indications was done. Out of them, 106 (2.7%) patients (79 females, 27 males) presented with bilateral diffuse thyroid gland uptake as an incidental finding. These patients were investigated retrospectively and various parameters such as age, sex, primary cancer site, maximal standardized uptake value (SUVmax), results of thyroid function tests (TFTs) and fine-needle aspiration cytology results were noted. The SUVmax values were correlated with serum thyroid stimulating hormone (S. TSH) levels using Pearson's correlation analysis. Pearson's correlation analysis. Clinical information and TFT (serum FT3, FT4 and TSH levels) results were available for 31 of the 106 patients (27 females, 4 males; mean age 51.5 years). Twenty-six out of 31 patients (84%) were having abnormal TFTs with abnormal TSH levels in 24/31 patients (mean S. TSH: 22.35 μIU/ml, median: 7.37 μIU/ml, range: 0.074-211 μIU/ml). Among 7 patients with normal TSH levels, 2 patients demonstrated low FT3 and FT4 levels. No significant correlation was found between maximum standardized uptake value and TSH levels (r = 0.115, P > 0.05). Incidentally detected diffuse thyroid gland uptake on F-18 FDG PET/CT scan was usually associated with hypothyroidism probably caused by autoimmune thyroiditis. Patients should be investigated promptly irrespective of the intensity of FDG uptake with TFTs to initiate replacement therapy and a USG examination to look for any suspicious nodules

  3. Synchrotron radiography and tomography of a PEM fuel cell; Synchrotron-Radiographie und -Tomographie einer PEM-Brennstoffzelle

    Energy Technology Data Exchange (ETDEWEB)

    Markoetter, Henning; Manke, Ingo [Helmholtzzentrum Berlin fuer Materialien und Energie, Berlin (Germany). Fachgruppe Bildgebende Verfahren; Arlt, Tobias [TU Berlin, Berlin (Germany); Banhart, John [TU Berlin, Institut fuer angewandte Materialforschung, Berlin (Germany); TU Berlin, Institut fuer Werkstoffwissenschaften und -technologien, Berlin (Germany); Riesemeier, Heinrich [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Arbeitsgruppe Synchrotronstrahlanalytik (Germany); Krueger, Philipp [CONSULECTRA Unternehmensberatung GmbH, Hamburg (Germany); Haussmann, Jan; Klages, Merle [Zentrum fuer Sonnenenergie- und Wasserstoff-Forschung, Stuttgart (Germany); Scholta, Joachim [Zentrum fuer Sonnenenergie- und Wasserstoff-Forschung, Stuttgart (Germany). Fachgruppe Brennstoffzellen-Stacks

    2013-06-01

    The three dimensional water distribution and transport pathways in gas diffusion layers (GDL) of a polymer electrolyte membrane fuell cell (PEM FC) are analysed at various operating conditions. The method of quasi in-situ X-ray tomography is used for a three dimensional visualization of the water distribution and the GDL structure. Based on the results of dynamic radiographic measurements water transport pathways are located and subsequently investigated in detail by means of tomography. The combination of 2D and 3D techniques allows for an identification of 3D transport pathways through the GDl.

  4. Deep-tissue temperature mapping by multi-illumination photoacoustic tomography aided by a diffusion optical model: a numerical study

    Science.gov (United States)

    Zhou, Yuan; Tang, Eric; Luo, Jianwen; Yao, Junjie

    2018-01-01

    Temperature mapping during thermotherapy can help precisely control the heating process, both temporally and spatially, to efficiently kill the tumor cells and prevent the healthy tissues from heating damage. Photoacoustic tomography (PAT) has been used for noninvasive temperature mapping with high sensitivity, based on the linear correlation between the tissue's Grüneisen parameter and temperature. However, limited by the tissue's unknown optical properties and thus the optical fluence at depths beyond the optical diffusion limit, the reported PAT thermometry usually takes a ratiometric measurement at different temperatures and thus cannot provide absolute measurements. Moreover, ratiometric measurement over time at different temperatures has to assume that the tissue's optical properties do not change with temperatures, which is usually not valid due to the temperature-induced hemodynamic changes. We propose an optical-diffusion-model-enhanced PAT temperature mapping that can obtain the absolute temperature distribution in deep tissue, without the need of multiple measurements at different temperatures. Based on the initial acoustic pressure reconstructed from multi-illumination photoacoustic signals, both the local optical fluence and the optical parameters including absorption and scattering coefficients are first estimated by the optical-diffusion model, then the temperature distribution is obtained from the reconstructed Grüneisen parameters. We have developed a mathematic model for the multi-illumination PAT of absolute temperatures, and our two-dimensional numerical simulations have shown the feasibility of this new method. The proposed absolute temperature mapping method may set the technical foundation for better temperature control in deep tissue in thermotherapy.

  5. Assessing pharmacokinetics of indocyanine green-loaded nanoparticle in tumor with a dynamic diffuse fluorescence tomography system

    Science.gov (United States)

    Zhang, Yanqi; Yin, Guoyan; Zhao, Huijuan; Ma, Wenjuan; Gao, Feng; Zhang, Limin

    2018-02-01

    Real-time and continuous monitoring of drug release in vivo is an important task in pharmaceutical development. Here, we devoted to explore a real-time continuous study of the pharmacokinetics of free indocyanine green (ICG) and ICG loaded in the shell-sheddable nanoparticles in tumor based on a dynamic diffuse fluorescence tomography (DFT) system: A highly-sensitive dynamic DFT system of CT-scanning mode generates informative and instantaneous sampling datasets; An analysis procedure extracts the pharmacokinetic parameters from the reconstructed time curves of the mean ICG concentration in tumor, using the Gauss-Newton scheme based on two-compartment model. Compared with the pharmacokinetic parameters of free ICG in tumor, the ICG loaded in the shell-sheddable nanoparticles shows efficient accumulation in tumor. The results demonstrate our proposed dynamic-DFT can provide an integrated and continuous view of the drug delivery of the injected agents in different formulations, which is helpful for the development of diagnosis and therapy for tumors.

  6. Multispectral and phase-contrast diffuse optical tomography of breast cancer during neoadjuvant chemotherapy: a case study

    Science.gov (United States)

    Liang, Xiaoping; Zhang, Qizhi; Staal, Stephen; Grobmyer, Stephen; Jiang, Huabei

    2009-02-01

    Multispectral and phase-contrast diffuse optical tomography are used to track treatment progress in a patient with locally advanced invasive carcinoma of the breast cancer during neoadjuvant chemotherapy. Two types of chemotherapy treatment including four cycles of Adriamycin/Cytoxin (AC cycles) and twelve cycles of Taxol/Herceptin (TH cycles) were applied to patient. A total of eight optical exams were performed before and within the chemotherapy. Images of tissue refractive index, and absorption and scattering coefficients, as well as oxy-hemoglobin and deoxy-hemoglobin concentrations along with scattering particle volume fraction and mean diameter of cellular components were all obtained. The tumor was identified through absorption and scattering images. Tumor shrinkage was observed during the course of chemotherapy from all the optical images. Our results show that oxy-hemoglobin, deoxy-hemoglobin and total hemoglobin in tumor decreased after chemotherapy compared to that of before chemotherapy. Significant changes in tumor refractive index along with tumor cellular morphology during the entire chemotherapy are also observed.

  7. Multimodal breast cancer imaging using coregistered dynamic diffuse optical tomography and digital breast tomosynthesis

    Science.gov (United States)

    Zimmermann, Bernhard B.; Deng, Bin; Singh, Bhawana; Martino, Mark; Selb, Juliette; Fang, Qianqian; Sajjadi, Amir Y.; Cormier, Jayne; Moore, Richard H.; Kopans, Daniel B.; Boas, David A.; Saksena, Mansi A.; Carp, Stefan A.

    2017-04-01

    Diffuse optical tomography (DOT) is emerging as a noninvasive functional imaging method for breast cancer diagnosis and neoadjuvant chemotherapy monitoring. In particular, the multimodal approach of combining DOT with x-ray digital breast tomosynthesis (DBT) is especially synergistic as DBT prior information can be used to enhance the DOT reconstruction. DOT, in turn, provides a functional information overlay onto the mammographic images, increasing sensitivity and specificity to cancer pathology. We describe a dynamic DOT apparatus designed for tight integration with commercial DBT scanners and providing a fast (up to 1 Hz) image acquisition rate to enable tracking hemodynamic changes induced by the mammographic breast compression. The system integrates 96 continuous-wave and 24 frequency-domain source locations as well as 32 continuous wave and 20 frequency-domain detection locations into low-profile plastic plates that can easily mate to the DBT compression paddle and x-ray detector cover, respectively. We demonstrate system performance using static and dynamic tissue-like phantoms as well as in vivo images acquired from the pool of patients recalled for breast biopsies at the Massachusetts General Hospital Breast Imaging Division.

  8. Ambulatory diffuse optical tomography and multimodality physiological monitoring system for muscle and exercise applications

    Science.gov (United States)

    Hu, Gang; Zhang, Quan; Ivkovic, Vladimir; Strangman, Gary E.

    2016-09-01

    Ambulatory diffuse optical tomography (aDOT) is based on near-infrared spectroscopy (NIRS) and enables three-dimensional imaging of regional hemodynamics and oxygen consumption during a person's normal activities. Although NIRS has been previously used for muscle assessment, it has been notably limited in terms of the number of channels measured, the extent to which subjects can be ambulatory, and/or the ability to simultaneously acquire synchronized auxiliary data such as electromyography (EMG) or electrocardiography (ECG). We describe the development of a prototype aDOT system, called NINscan-M, capable of ambulatory tomographic imaging as well as simultaneous auxiliary multimodal physiological monitoring. Powered by four AA size batteries and weighing 577 g, the NINscan-M prototype can synchronously record 64-channel NIRS imaging data, eight channels of EMG, ECG, or other analog signals, plus force, acceleration, rotation, and temperature for 24+ h at up to 250 Hz. We describe the system's design, characterization, and performance characteristics. We also describe examples of isometric, cycle ergometer, and free-running ambulatory exercise to demonstrate tomographic imaging at 25 Hz. NINscan-M represents a multiuse tool for muscle physiology studies as well as clinical muscle assessment.

  9. Performance Enhancement of Pharmacokinetic Diffuse Fluorescence Tomography by Use of Adaptive Extended Kalman Filtering.

    Science.gov (United States)

    Wang, Xin; Wu, Linhui; Yi, Xi; Zhang, Yanqi; Zhang, Limin; Zhao, Huijuan; Gao, Feng

    2015-01-01

    Due to both the physiological and morphological differences in the vascularization between healthy and diseased tissues, pharmacokinetic diffuse fluorescence tomography (DFT) can provide contrast-enhanced and comprehensive information for tumor diagnosis and staging. In this regime, the extended Kalman filtering (EKF) based method shows numerous advantages including accurate modeling, online estimation of multiparameters, and universal applicability to any optical fluorophore. Nevertheless the performance of the conventional EKF highly hinges on the exact and inaccessible prior knowledge about the initial values. To address the above issues, an adaptive-EKF scheme is proposed based on a two-compartmental model for the enhancement, which utilizes a variable forgetting-factor to compensate the inaccuracy of the initial states and emphasize the effect of the current data. It is demonstrated using two-dimensional simulative investigations on a circular domain that the proposed adaptive-EKF can obtain preferable estimation of the pharmacokinetic-rates to the conventional-EKF and the enhanced-EKF in terms of quantitativeness, noise robustness, and initialization independence. Further three-dimensional numerical experiments on a digital mouse model validate the efficacy of the method as applied in realistic biological systems.

  10. Reduction of Poisson noise in measured time-resolved data for time-domain diffuse optical tomography.

    Science.gov (United States)

    Okawa, S; Endo, Y; Hoshi, Y; Yamada, Y

    2012-01-01

    A method to reduce noise for time-domain diffuse optical tomography (DOT) is proposed. Poisson noise which contaminates time-resolved photon counting data is reduced by use of maximum a posteriori estimation. The noise-free data are modeled as a Markov random process, and the measured time-resolved data are assumed as Poisson distributed random variables. The posterior probability of the occurrence of the noise-free data is formulated. By maximizing the probability, the noise-free data are estimated, and the Poisson noise is reduced as a result. The performances of the Poisson noise reduction are demonstrated in some experiments of the image reconstruction of time-domain DOT. In simulations, the proposed method reduces the relative error between the noise-free and noisy data to about one thirtieth, and the reconstructed DOT image was smoothed by the proposed noise reduction. The variance of the reconstructed absorption coefficients decreased by 22% in a phantom experiment. The quality of DOT, which can be applied to breast cancer screening etc., is improved by the proposed noise reduction.

  11. Dynamic light scattering optical coherence tomography.

    Science.gov (United States)

    Lee, Jonghwan; Wu, Weicheng; Jiang, James Y; Zhu, Bo; Boas, David A

    2012-09-24

    We introduce an integration of dynamic light scattering (DLS) and optical coherence tomography (OCT) for high-resolution 3D imaging of heterogeneous diffusion and flow. DLS analyzes fluctuations in light scattered by particles to measure diffusion or flow of the particles, and OCT uses coherence gating to collect light only scattered from a small volume for high-resolution structural imaging. Therefore, the integration of DLS and OCT enables high-resolution 3D imaging of diffusion and flow. We derived a theory under the assumption that static and moving particles are mixed within the OCT resolution volume and the moving particles can exhibit either diffusive or translational motion. Based on this theory, we developed a fitting algorithm to estimate dynamic parameters including the axial and transverse velocities and the diffusion coefficient. We validated DLS-OCT measurements of diffusion and flow through numerical simulations and phantom experiments. As an example application, we performed DLS-OCT imaging of the living animal brain, resulting in 3D maps of the absolute and axial velocities, the diffusion coefficient, and the coefficient of determination.

  12. A fortran program for elastic scattering of deuterons with an optical model containing tensorial potentials; Programme fortran pour la diffusion elastique de deutons avec un modele optique contenant des termes tensoriels

    Energy Technology Data Exchange (ETDEWEB)

    Raynal, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The optical model has been applied with success to the elastic scattering of particles of spin 0 and 1/2 and to a lesser degree to that of deuterons. For particles of spin l/2, an LS coupling term is ordinarily used; this term is necessary to obtain a polarization; for deuterons, this coupling has been already introduced, but the possible forms of potentials are more numerous (in this case, scalar products of a second rank spin tensor with a tensor of the same rank in space or momentum can occur). These terms which may be necessary are primarily important for the tensor polarization. This problem is of particular interest at Saclay since a beam of polarized deuterons has become available. The FORTRAN program SPM 037 permits the study of the effect of tensorial potentials constructed from the distance of the deuteron from the target and its angular momentum with respect to it. This report should make possible the use and even the modification of the program. It consists of: a description of the problem and of the notation employed, a presentation of the methods adopted, an indication of the necessary data and how they should be introduced, and finally tables of symbols which are in equivalence or common statements: these tables must be considered when making any modification. (author) [French] Le modele optique a ete applique avec succes a la diffusion elastique des particules de spin nul et 1/2 et dans une moindre mesure a celle des deutons. Pour les particules de spin 1/2, on utilise habituellement un couplage LS, necessaire pour calculer la polarisation; pour les deutons, ce couplage a deja ete introduit, mais les formes de potentiel possibles sont plus nombreuses (intervention de produits scalaires d'un tenseur d'ordre 2 de spin avec un tenseur du meme ordre d'espace ou d'impulsion) et celles qui peuvent etre eventuellement necessaires ont une importance capitale pour la polarisation tensorielle. Ce probleme revet a Saclay un interet particulier depuis la mise

  13. A fortran program for elastic scattering of deuterons with an optical model containing tensorial potentials; Programme fortran pour la diffusion elastique de deutons avec un modele optique contenant des termes tensoriels

    Energy Technology Data Exchange (ETDEWEB)

    Raynal, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The optical model has been applied with success to the elastic scattering of particles of spin 0 and 1/2 and to a lesser degree to that of deuterons. For particles of spin l/2, an LS coupling term is ordinarily used; this term is necessary to obtain a polarization; for deuterons, this coupling has been already introduced, but the possible forms of potentials are more numerous (in this case, scalar products of a second rank spin tensor with a tensor of the same rank in space or momentum can occur). These terms which may be necessary are primarily important for the tensor polarization. This problem is of particular interest at Saclay since a beam of polarized deuterons has become available. The FORTRAN program SPM 037 permits the study of the effect of tensorial potentials constructed from the distance of the deuteron from the target and its angular momentum with respect to it. This report should make possible the use and even the modification of the program. It consists of: a description of the problem and of the notation employed, a presentation of the methods adopted, an indication of the necessary data and how they should be introduced, and finally tables of symbols which are in equivalence or common statements: these tables must be considered when making any modification. (author) [French] Le modele optique a ete applique avec succes a la diffusion elastique des particules de spin nul et 1/2 et dans une moindre mesure a celle des deutons. Pour les particules de spin 1/2, on utilise habituellement un couplage LS, necessaire pour calculer la polarisation; pour les deutons, ce couplage a deja ete introduit, mais les formes de potentiel possibles sont plus nombreuses (intervention de produits scalaires d'un tenseur d'ordre 2 de spin avec un tenseur du meme ordre d'espace ou d'impulsion) et celles qui peuvent etre eventuellement necessaires ont une importance capitale pour la polarisation tensorielle. Ce probleme revet a Saclay un interet

  14. 3D optical tomography in the presence of void regions

    Science.gov (United States)

    Riley, J.; Dehghani, Hamid; Schweiger, Martin; Arridge, Simon R.; Ripoll, Jorge; Nieto-Vesperinas, Manuel

    2000-12-01

    We present an investigation of the effect of a 3D non-scattering gap region on image reconstruction in diffuse optical tomography. The void gap is modelled by the Radiosity-Diffusion method and the inverse problem is solved using the adjoint field method. The case of a sphere with concentric spherical gap is used as an example.

  15. Topographie en tomographie en coherence optique (OCT) des ...

    African Journals Online (AJOL)

    disc (C/D) clinique de 0,4 étaient enregistrés. La référence pour le topogramme de la papille pour les comparaisons dans notre étude était celle du 19e symposium de recherche sur le glaucome tenu à Chicago en Novembre 2012. Résultats: ...

  16. Prognostic significance of metabolic tumor burden by positron emission tomography/computed tomography in patients with relapsed/refractory diffuse large B-cell lymphoma.

    Science.gov (United States)

    Tateishi, Ukihide; Tatsumi, Mitsuaki; Terauchi, Takashi; Ando, Kiyoshi; Niitsu, Nozomi; Kim, Won Seog; Suh, Cheolwon; Ogura, Michinori; Tobinai, Kensei

    2015-02-01

    The aim of the present study was to investigate the feasibility of measuring metabolic tumor burden using [F-18] fluorodeoxyglucose ((18) F-FDG) positron emission tomography/computed tomography (PET/CT) in patients with relapsed or refractory diffuse large B-cell lymphoma (DLBCL) treated with bendamustine-rituximab. Because the standardized uptake value is a critical parameter of tumor characterization, we carried out a phantom study of (18) F-FDG PET/CT to ensure quality control for 28 machines in the 24 institutions (Japan, 17 institutions; Korea, 7 institutions) participating in our clinical study. Fifty-five patients with relapsed or refractory DLBCL were enrolled. The (18) F-FDG PET/CT was acquired before treatment, after two cycles, and after the last treatment cycle. Treatment response was assessed after two cycles and after the last cycle using the Lugano classification. Using this classification, remission was complete in 15 patients (27%) and incomplete in 40 patients (73%) after two cycles of therapy, and remission was complete in 32 patients (58%) and incomplete in 23 patients (42%) after the last treatment cycle. The percentage change in all PET/CT parameters except for the area under the curve of the cumulative standardized uptake value-volume histogram was significantly greater in complete response patients than in non-complete response patients after two cycles and the last cycle. The Cox proportional hazard model and best subset selection method revealed that the percentage change of the sum of total lesion glycolysis after the last cycle (relative risk, 5.24; P = 0.003) was an independent predictor of progression-free survival. The percent change of sum of total lesion glycolysis, calculated from PET/CT, can be used to quantify the response to treatment and can predict progression-free survival after the last treatment cycle in patients with relapsed or refractory DLBCL treated with bendamustine-rituximab. © 2014 The Authors. Cancer Science

  17. Mapping cortical haemodynamics during neonatal seizures using diffuse optical tomography: A case study

    Directory of Open Access Journals (Sweden)

    Harsimrat Singh

    2014-01-01

    Full Text Available Seizures in the newborn brain represent a major challenge to neonatal medicine. Neonatal seizures are poorly classified, under-diagnosed, difficult to treat and are associated with poor neurodevelopmental outcome. Video-EEG is the current gold-standard approach for seizure detection and monitoring. Interpreting neonatal EEG requires expertise and the impact of seizures on the developing brain remains poorly understood. In this case study we present the first ever images of the haemodynamic impact of seizures on the human infant brain, obtained using simultaneous diffuse optical tomography (DOT and video-EEG with whole-scalp coverage. Seven discrete periods of ictal electrographic activity were observed during a 60 minute recording of an infant with hypoxic–ischaemic encephalopathy. The resulting DOT images show a remarkably consistent, high-amplitude, biphasic pattern of changes in cortical blood volume and oxygenation in response to each electrographic event. While there is spatial variation across the cortex, the dominant haemodynamic response to seizure activity consists of an initial increase in cortical blood volume prior to a large and extended decrease typically lasting several minutes. This case study demonstrates the wealth of physiologically and clinically relevant information that DOT–EEG techniques can yield. The consistency and scale of the haemodynamic responses observed here also suggest that DOT–EEG has the potential to provide improved detection of neonatal seizures.

  18. Self-diffusion in single crystalline silicon nanowires

    Science.gov (United States)

    Südkamp, T.; Hamdana, G.; Descoins, M.; Mangelinck, D.; Wasisto, H. S.; Peiner, E.; Bracht, H.

    2018-04-01

    Self-diffusion experiments in single crystalline isotopically controlled silicon nanowires with diameters of 70 and 400 nm at 850 and 1000 °C are reported. The isotope structures were first epitaxially grown on top of silicon substrate wafers. Nanowires were subsequently fabricated using a nanosphere lithography process in combination with inductively coupled plasma dry reactive ion etching. Three-dimensional profiling of the nanosized structure before and after diffusion annealing was performed by means of atom probe tomography (APT). Self-diffusion profiles obtained from APT analyses are accurately described by Fick's law for self-diffusion. Data obtained for silicon self-diffusion in nanowires are equal to the results reported for bulk silicon crystals, i.e., finite size effects and high surface-to-volume ratios do not significantly affect silicon self-diffusion. This shows that the properties of native point defects determined from self-diffusion in bulk crystals also hold for nanosized silicon structures with diameters down to 70 nm.

  19. Primary pulmonary lymphoma-role of fluoro-deoxy-glucose positron emission tomography-computed tomography in the initial staging and evaluating response to treatment - case reports and review of literature

    International Nuclear Information System (INIS)

    Agarwal, Krishan Kant; Dhanapathi, Halanaik; Nazar, Aftab Hasan; Kumar, Rakesh

    2016-01-01

    Primary pulmonary lymphoma (PPL) is an uncommon entity of non-Hodgkin lymphoma, which accounts for <1% of all cases of lymphoma. We present two rare cases of PPL of diffuse large B-cell lymphoma, which underwent 18 fluorine fluoro-deoxy-glucose positron emission tomography-computed tomography for initial staging and response evaluation after chemotherapy

  20. Two-step reconstruction method using global optimization and conjugate gradient for ultrasound-guided diffuse optical tomography.

    Science.gov (United States)

    Tavakoli, Behnoosh; Zhu, Quing

    2013-01-01

    Ultrasound-guided diffuse optical tomography (DOT) is a promising method for characterizing malignant and benign lesions in the female breast. We introduce a new two-step algorithm for DOT inversion in which the optical parameters are estimated with the global optimization method, genetic algorithm. The estimation result is applied as an initial guess to the conjugate gradient (CG) optimization method to obtain the absorption and scattering distributions simultaneously. Simulations and phantom experiments have shown that the maximum absorption and reduced scattering coefficients are reconstructed with less than 10% and 25% errors, respectively. This is in contrast with the CG method alone, which generates about 20% error for the absorption coefficient and does not accurately recover the scattering distribution. A new measure of scattering contrast has been introduced to characterize benign and malignant breast lesions. The results of 16 clinical cases reconstructed with the two-step method demonstrates that, on average, the absorption coefficient and scattering contrast of malignant lesions are about 1.8 and 3.32 times higher than the benign cases, respectively.

  1. Diffuse and vascular hepatic diseases

    International Nuclear Information System (INIS)

    Kreimeyer, S.; Grenacher, L.

    2011-01-01

    In addition to focal liver lesions, diffuse and vascular disorders of the liver represent a wide spectrum of liver diseases which are from the radiological point of view often difficult or nearly impossible to diagnose. Classical diagnostic methods are computed tomography and magnetic resonance imaging in addition to ultrasound. Diffuse parenchymal damage caused by diseases of various etiologies is therefore difficult to evaluate because it often lacks characteristic morphological features. For hepatic steatosis, hemochromatosis/siderosis as an example of a diffuse storage disease and sarcoidosis and candidiasis as infectious/inflammatory diseases, an image-based diagnosis is appropriate in some cases. For most diffuse liver diseases, however only nonspecific changes are visualized. Vascular pathologies of the liver, such as the Budd-Chiari syndrome and portal vein thrombosis, however, can usually be diagnosed very clearly using radiology and there is also a very effective interventional radiological treatment. Chronic diseases very often culminate in liver cirrhosis which is highly associated with an increased risk of liver cancer. (orig.) [de

  2. 18F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance in Lymphoma: Comparison With 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography and With the Addition of Magnetic Resonance Diffusion-Weighted Imaging.

    Science.gov (United States)

    Giraudo, Chiara; Raderer, Markus; Karanikas, Georgios; Weber, Michael; Kiesewetter, Barbara; Dolak, Werner; Simonitsch-Klupp, Ingrid; Mayerhoefer, Marius E

    2016-03-01

    The aim of this study was to compare F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lymphoma and non-Hodgkin lymphoma, without restriction to FDG-avid subytpes. Patients with histologically proven lymphoma were enrolled in this prospective, institutional review board-approved study. After a single F-FDG injection, patients consecutively underwent F-FDG PET[Fraction Slash]CT and F-FDG PET/MR on the same day for staging or restaging. Three sets of images were analyzed separately: F-FDG PET/CT, F-FDG PET/MR without DWI, and F-FDG PET/MR with DWI. Region-based agreement and examination-based sensitivity and specificity were calculated for F-FDG PET/CT, F-FDG PET/MR without DWI, and F-FDG PET/MR DWI. Maximum and mean standardized uptake values (SUVmax, SUVmean) on F-FDG PET/CT and F-FDG PET/MR were compared and correlated with minimum and mean apparent diffusion coefficients (ADCmin, ADCmean). Thirty-four patients with a total of 40 examinations were included. Examination-based sensitivities for F-FDG PET/CT, F-FDG PET/MR, and F-FDG PET/MR DWI were 82.1%, 85.7%, and 100%, respectively; specificities were 100% for all 3 techniques; and accuracies were 87.5%, 90%, and 100%, respectively. F-FDG PET/CT was false negative in 5 of 40 examinations (all with mucosa-associated lymphoid tissue lymphoma), and F-FDG PET/MR (without DWI) was false negative in 4 of 40 examinations. Region-based percentages of agreement were 99% (κ, 0.95) between F-FDG PET/MR DWI and F-FDG PET/CT, 99.2% (κ, 0.96) between F-FDG PET/MR and F-FDG PET/CT, and 99.4% (κ, 0.97) between F-FDG PET/MR DWI and F-FDG PET/MR. There was a strong correlation between F-FDG PET/CT and F-FDG PET/MR for SUVmax (r = 0.83) and SUVmean (r = 0.81) but no significant correlation between ADCmin and SUVmax

  3. Diffusion in Altered Tonalite Sample Using Time Domain Diffusion Simulations in Tomographic Images Combined with Lab-scale Diffusion Experiments

    Science.gov (United States)

    Voutilainen, M.; Sardini, P.; Togneri, L.; Siitari-Kauppi, M.; Timonen, J.

    2010-12-01

    In this work an effect of rock heterogeneity on diffusion was investigated. Time domain diffusion simulations were used to compare behavior of diffusion in homogeneous and heterogeneous 3D media. Tomographic images were used as heterogeneous rock media. One altered tonalite sample from Sievi, Finland, was chosen as test case for introduced analysis procedure. Effective diffusion coefficient of tonalite sample was determined with lab-scale experiments and the same coefficient was used also for homogeneous media. Somewhat technically complicated mathematical solution for analysis of through diffusion experiment is shortly described. Computed tomography (CT) is already quite widely used in many geological, petrological, and paleontological applications when the three-dimensional (3D) structure of the material is of interest, and is an excellent method for gaining information especially about its heterogeneity, grain size, or porosity. In addition to offering means for quantitative characterization, CT provides a lot of qualitative information [1]. A through -diffusion laboratory experiment using radioactive tracer was fitted using the Time Domain Diffusion (TDD) method. This rapid particle tracking method allows simulation of the heterogeneous diffusion based on pore-scale images and local values of diffusivities [2]. As a result we found out that heterogeneity has only a small effect to diffusion coefficient and in-diffusion profile for used geometry. Also direction dependency was tested and was found to be negligible. Whereas significant difference between generally accepted value and value obtained from simulations for constant m in Archie’s law was found. [1] Voutilainen, M., Siitari-Kauppi, M., Sardini, P., and Timonen, J., (2010). On pore-space characterization of an altered tonalite by X-ray µCT and the 14C-PMMA method (in progress). [2] Sardini, P., Robinet, J., Siitari-Kauppi, M., Delay, F., and Hellmuth, K-H, (2007). On direct simulation of heterogeneous

  4. Photoacoustic Tomography

    Science.gov (United States)

    Wang, Lihong V.

    Photoacoustic tomography (PAT) refers to imaging that is based on the photoacoustic effect. Although the photoacoustic effect as a physical phenomenon was first reported on by Alexander Graham Bell in 1880 [1], PAT as an imaging technology was developed only after the advent of ultrasonic transducers, computers, and lasers [2-31]. A review on biomedical photoacoustics is available [32]. The motivation for PAT is to combine optical-absorption contrast with ultrasonic spatial resolution for deep imaging in the optical quasi-diffusive or diffusive regime. In PAT, the tissue is irradiated by usually a short-pulsed laser beam to achieve a thermal and acoustic impulse response (Fig. 19.1). Locally absorbed light is converted into heat, which is further converted to a pressure rise via thermo-elastic expansion. The initial pressure rise - determined by the local optical absorption coefficient (μ â ), fluence (ψ) and other thermal and mechanical properties - propagates as an ultrasonic wave, which is referred to as a photoacoustic wave.

  5. Intergranular Pressure Solution in Nacl: Grain-To-Grain Contact Experiments under the Optical Microscope Dissolution sous contrainte dans NaCl : expériences de contact grain à grain sous microscope optique

    Directory of Open Access Journals (Sweden)

    Spiers C. J.

    2006-12-01

    effective diffusivity varying with contact force and on-going convergence. The results agree broadly with those of previous compaction creep experiments performed using wet halite powder. Discrepancies with other workers results for single-contact dissolution experiments can be explained in terms of differences in experimental configuration and competition between driving forces. La dissolution sous contrainte (IPS - Intergranular Pressure Solution représente un mécanisme de lithification, de compaction et de déformation à l'échelle géologique pour une large gamme de roches. Les études expérimentales d'IPS réalisées sur des agrégats de quartz n'ont pas été couronnées de succès en raison d'un taux faible d'IPS, et les expériences IPS réalisées en utilisant une halite saturée comme analogue de roche (Spiers et Schutjens, 1990 ; Hickman et Evans, 1991 ont laissé des incertitudes quant au détail des mécanismes IPS et à la structure/saturation au contact du grain dans ce matériau. La présente étude fait état de quatre expériences de dissolution de contact réalisées sous microscope optique afin d'étudier le mécanisme et la cinétique de l'IPS pour des contacts simples halite/halite et halite/verre, chargés en eau salée (température ambiante. Des forces normales de contact dans la gamme de 1,0 à 2,6 N ont été appliquées en présence d'eau salée saturée en NaCl, induisant des pressions de 0,8 à 7,4 MPa. Des pertes de masse et des convergences - fonction du temps - ont été observées pour tous les contacts. Dans tous les cas, le fait de charger le contact (ou d'augmenter la charge sur le contact a conduit à la formation immédiate d'une morphologie de contact rugueuse, composée d'un motif d'îles et de canaux, contrôlé par des caractéristiques cristallographiques, à l'échelle de quelques microns. Cette microstructure non équilibrée a évolué dans le temps vers une face de contact optiquement plate. Le processus de convergence

  6. Isotopic analysis using optical spectroscopy (1963); Analyse isotopique par spectroscopie optique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Gerstenkorn, S [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The isotopic displacement in the atomic lines of certain elements (H, He, Li, Ne, Sr, Hg, Pb, U, Pu) is used for dosing these elements isotopically. The use of the Fabry-Perot photo-electric interference spectrometer is shown to be particularly adapted for this sort of problem: in each case we give on the one hand the essential results obtained with this apparatus, and on the other hand the results previously obtained with a conventional apparatus (grating, photographic plate). These results together give an idea of the possibilities of optical spectroscopy: in the best case, the precision which may be expected is of the order of 1 to 2 per cent for isotopes whose concentration is about 1 per cent. (author) [French] Le deplacement isotopique dans les raies atomiques de certains elements (H, He, Li, Ne, Sr, Hg, Pb, U, Pu) est utilise pour effectuer le dosage isotopique de ces elements. L'utilisation du spectrometre interferentiel Fabry-Perot photoelectrique se revele particulierement adapte a ce genre de probleme: dans chaque cas, nous donnons d'une part l'essentiel des resultats obtenus avec cet appareil, et d'autre part, les resultats obtenus anterieurement a l'aide de l'appareillage classique (reseau, plaque photographique). L'ensemble de ces informations donne une idee des possibilites offertes par la spectroscopie optique: dans le meilleur des cas, la precision que l'on peut esperer est de l'ordre de 1 a 2 pour cent pour des isotopes dont la concentration est de l'ordre de 1 pour cent. (auteur)

  7. Lung diffusing capacity for nitric oxide and carbon monoxide in relation to morphological changes as assessed by computed tomography in patients with cystic fibrosis

    Directory of Open Access Journals (Sweden)

    Nowak Dennis

    2009-06-01

    Full Text Available Abstract Background Due to large-scale destruction, changes in membrane diffusion (Dm may occur in cystic fibrosis (CF, in correspondence to alterations observed by computed tomography (CT. Dm can be easily quantified via the diffusing capacity for nitric oxide (DLNO, as opposed to the conventional diffusing capacity for carbon monoxide (DLCO. We thus studied the relationship between DLNO as well as DLCO and a CF-specific CT score in patients with stable CF. Methods Simultaneous single-breath determinations of DLNO and DLCO were performed in 21 CF patients (mean ± SD age 35 ± 9 y, FEV1 66 ± 28%pred. Patients also underwent spirometry and bodyplethysmography. CT scans were evaluated via the Brody score and rank correlations (rS with z-scores of functional measures were computed. Results CT scores correlated best with DLNO (rS = -0.83; p S = -0.63; p CO (rS = -0.79; p NO were significantly lower than for DLCO (p 1, IVC or bodyplethysmographic (e.g., SRaw, RV/TLC indices were weaker than for DLNO or DLCO but most of them were also significant (p Conclusion In this cross sectional study in patients with CF, DLNO and DLCO reflected CT-morphological alterations of the lung better than other measures. Thus the combined diffusing capacity for NO and CO may play a future role for the non-invasive, functional assessment of structural alterations of the lung in CF.

  8. Optical coherent tomography measurements of the diffusion rate of water and drugs in an isolated and whole cornea

    International Nuclear Information System (INIS)

    Larin, Kirill V; Ghosn, M G

    2006-01-01

    The passive diffusion of drugs through the epithelial surfaces of an eye (the most widespread method for medical treatment of various diseases) is considered. The permeability of water and drugs through rabbit cornea was measured in the isolated cornea (separate from an eye) and in the whole cornea. The permeability coefficients of water and dexamethasone were estimated by the method of optical coherence tomography (OCT). Because multiple photon scattering introduces noise and distortions to the OCT signal, measurements were performed at depths up to 500 μm where most likely single scattering of light occurs in cornea. It is shown that the permeability coefficients in the isolated and whole cornea strongly differ from each other. For example, the water permeability in the isolated and whole cornea is (7.09±0.12)x10 -5 and (1.71±0.51)x10 -5 cm s -1 , respectively. (special issue devoted to multiple radiation scattering in random media)

  9. Towards real-time diffuse optical tomography for imaging brain functions cooperated with Kalman estimator

    Science.gov (United States)

    Wang, Bingyuan; Zhang, Yao; Liu, Dongyuan; Ding, Xuemei; Dan, Mai; Pan, Tiantian; Wang, Yihan; Li, Jiao; Zhou, Zhongxing; Zhang, Limin; Zhao, Huijuan; Gao, Feng

    2018-02-01

    Functional near-infrared spectroscopy (fNIRS) is a non-invasive neuroimaging method to monitor the cerebral hemodynamic through the optical changes measured at the scalp surface. It has played a more and more important role in psychology and medical imaging communities. Real-time imaging of brain function using NIRS makes it possible to explore some sophisticated human brain functions unexplored before. Kalman estimator has been frequently used in combination with modified Beer-Lamber Law (MBLL) based optical topology (OT), for real-time brain function imaging. However, the spatial resolution of the OT is low, hampering the application of OT in exploring some complicated brain functions. In this paper, we develop a real-time imaging method combining diffuse optical tomography (DOT) and Kalman estimator, much improving the spatial resolution. Instead of only presenting one spatially distributed image indicating the changes of the absorption coefficients at each time point during the recording process, one real-time updated image using the Kalman estimator is provided. Its each voxel represents the amplitude of the hemodynamic response function (HRF) associated with this voxel. We evaluate this method using some simulation experiments, demonstrating that this method can obtain more reliable spatial resolution images. Furthermore, a statistical analysis is also conducted to help to decide whether a voxel in the field of view is activated or not.

  10. Experimental evaluation of electrical conductivity imaging of anisotropic brain tissues using a combination of diffusion tensor imaging and magnetic resonance electrical impedance tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sajib, Saurav Z. K.; Jeong, Woo Chul; Oh, Tong In; Kim, Hyung Joong, E-mail: bmekim@khu.ac.kr, E-mail: ejwoo@khu.ac.kr; Woo, Eung Je, E-mail: bmekim@khu.ac.kr, E-mail: ejwoo@khu.ac.kr [Department of Biomedical Engineering, Kyung Hee University, Seoul 02447 (Korea, Republic of); Kyung, Eun Jung [Department of Pharmacology, Chung-Ang University, Seoul 06974 (Korea, Republic of); Kim, Hyun Bum [Department of East-West Medical Science, Kyung Hee University, Yongin 17104 (Korea, Republic of); Kwon, Oh In [Department of Mathematics, Konkuk University, Seoul 05029 (Korea, Republic of)

    2016-06-15

    Anisotropy of biological tissues is a low-frequency phenomenon that is associated with the function and structure of cell membranes. Imaging of anisotropic conductivity has potential for the analysis of interactions between electromagnetic fields and biological systems, such as the prediction of current pathways in electrical stimulation therapy. To improve application to the clinical environment, precise approaches are required to understand the exact responses inside the human body subjected to the stimulated currents. In this study, we experimentally evaluate the anisotropic conductivity tensor distribution of canine brain tissues, using a recently developed diffusion tensor-magnetic resonance electrical impedance tomography method. At low frequency, electrical conductivity of the biological tissues can be expressed as a product of the mobility and concentration of ions in the extracellular space. From diffusion tensor images of the brain, we can obtain directional information on diffusive movements of water molecules, which correspond to the mobility of ions. The position dependent scale factor, which provides information on ion concentration, was successfully calculated from the magnetic flux density, to obtain the equivalent conductivity tensor. By combining the information from both techniques, we can finally reconstruct the anisotropic conductivity tensor images of brain tissues. The reconstructed conductivity images better demonstrate the enhanced signal intensity in strongly anisotropic brain regions, compared with those resulting from previous methods using a global scale factor.

  11. Diffuse sclerosing variant of papillary thyroid carcinoma: case report

    International Nuclear Information System (INIS)

    Lee, Seung Chan; Kim, Dong Wook

    2006-01-01

    Diffuse sclerosing papillary carcinoma (DSPC) is a variant of papillary thyroid carcinoma (PTC), but it shows more aggressive clinical course and a poorer prognosis than the other types of PTC. Most PTCs show a focal nodular pattern in the thyroid on the imaging modalities, but DSPC reveals a diffuse infiltrating configuration in the thyroid without any focal nodular lesion. To our knowledge, there are scant radiological reports of diffuse sclerosing variant of papillary thyroid carcinoma. In this report, we present the case of a patient with DSPC who showed the characteristic findings on sonography and computed tomography

  12. Evaluation of diffuse hepatic disease by computed tomography, 1

    International Nuclear Information System (INIS)

    Tada, Akira; Shikae, Mikio; Morinaga, Kenichi; Morikawa, Toshihiro; Nei, Hirokazu.

    1979-01-01

    Liver attenuation values of 53 diffuse hepatic disease were measured, and compared with those of normal subjects. In normal subjects mean CT values of the liver was 62.3, that of the spleen was 53.2. But in diffuse hepatic disease, all group's mean CT values of the liver was decreased, especially at fatty liver and acute hepatitis. In all cases of fatty liver, CT values of the liver were lower than that of the spleen. In 39 cases of 53 patients, change of CT values of the liver were measured using biliary tract contrast agents. In another 39 cases of 53 patients, were evaluated histological fat deposit and CT values of the liver. Correlation between histological fat deposit and CT values was good. Diagnosis of the moderate fatty liver and quantitative analysis was possible by CT values alone. (author)

  13. Diffuse and vascular hepatic diseases; Diffuse und vaskulaere Lebererkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Kreimeyer, S.; Grenacher, L. [Universitaetsklinikum Heidelberg, Abteilung Diagnostische und Interventionelle Radiologie, Heidelberg (Germany)

    2011-08-15

    In addition to focal liver lesions, diffuse and vascular disorders of the liver represent a wide spectrum of liver diseases which are from the radiological point of view often difficult or nearly impossible to diagnose. Classical diagnostic methods are computed tomography and magnetic resonance imaging in addition to ultrasound. Diffuse parenchymal damage caused by diseases of various etiologies is therefore difficult to evaluate because it often lacks characteristic morphological features. For hepatic steatosis, hemochromatosis/siderosis as an example of a diffuse storage disease and sarcoidosis and candidiasis as infectious/inflammatory diseases, an image-based diagnosis is appropriate in some cases. For most diffuse liver diseases, however only nonspecific changes are visualized. Vascular pathologies of the liver, such as the Budd-Chiari syndrome and portal vein thrombosis, however, can usually be diagnosed very clearly using radiology and there is also a very effective interventional radiological treatment. Chronic diseases very often culminate in liver cirrhosis which is highly associated with an increased risk of liver cancer. (orig.) [German] Neben den fokalen Leberlaesionen stellen diffuse und vaskulaere Lebererkrankungen ein weites Spektrum an Erkrankungen der Leber dar, die radiologisch oft schwer oder gar nicht diagnostizierbar sind. Klassische diagnostische Verfahren sind dabei neben dem Ultraschall die Computertomographie und die Magnetresonanztomographie. Diffuse Parenchymschaeden, bedingt durch Erkrankungen unterschiedlichster Aetiologie, sind deshalb schwierig evaluierbar, weil haeufig charakteristische bildmorphologische Merkmale fehlen. Die Steatosis hepatis, die Haemochromatose/Siderose als Beispiel der Speicherkrankheiten sowie die Sarkoidose und die Candidose als infektioes-entzuendliche Erkrankungen sind einer bildbasierten Diagnosestellung z. T. zugaenglich, bei den meisten diffusen Lebererkrankungen jedoch zeigen sich lediglich unspezifische

  14. Co-registration of fluorescence diffuse optical tomography (fDOT) with positron emission tomography (PET) and development of multi-angle fDOT

    International Nuclear Information System (INIS)

    Tong, X.

    2012-01-01

    This thesis concerns the image processing of fluorescence diffuse optical tomography (fDOT), following two axes: fDOT image co-registration with PET (positron emission tomography) image and improvement of fDOT image reconstructions using mirrors to collect additional projections. It is presented in two parts:In the first part, an automatic method to co-register the fDOT images with PET images has been developed to correlate all the information from each modality. This co-registration method is based on automatic detection of fiducial markers (FM) present in both modalities. The particularity of this method is the use of optical surface image obtained in fDOT imaging system, which serves to identify the Z position of FM in optical images. We tested this method on a model of mice bearing tumor xenografts of MEN2A cancer cells that mimic a human medullary thyroid carcinoma, after a double injection of radiotracer [ 18 F] 2-fluoro-2-Deoxy-D-glucose (FDG) for PET imaging and optical fluorescent infrared tracer Sentidye. With the accuracy of our method, we can demonstrate that the signal of Sentidye is present both in the tumor and surrounding vessels.The fDOT reconstruction image quality is degraded along the Z axis due to a limited number of projections for reconstruction. In the second part, the work is oriented towards a new method of fDOT image reconstruction with a new multi-angle data acquisition system in placing two mirrors on each side of the animal. This work was conducted in collaboration with the CS Department of University College London (UCL), a partner of the European project FMT-XCT. TOAST software developed by this team was used as source code for the reconstruction algorithm, and was modified to adapt to the concerned problem. After several tests on the adjustment of program parameters, we applied this method on a phantom that simulating the biological tissue and on mice. The results showed an improvement in the reconstructed image of a semi

  15. computed tomography features of basal ganglia and periventricular

    African Journals Online (AJOL)

    HIV is probably the most common cause of basal ganglia and periventricular calcification today. on-enhanced computed tomography (NECT) shows diffuse cerebral atrophy in 90% of cases. Bilateral, symmetrical basal ganglia calcification is seen in 30% of cases, but virtually never before 1 year of age.1. CMV (FIG.2).

  16. Multi-spectral and fluorescence diffuse optical tomography of breast cancer

    Science.gov (United States)

    Corlu, Alper

    Multi-spectral and fluorescence diffuse optical tomography (DOT) techniques are explored and applied to image human breast cancer in vivo. Image reconstruction algorithms that utilize first and second order gradient information are described in detail. Breast DOT requires large computational memory and long run times. To this end, parallel computation techniques were developed appropriate to each reconstruction algorithm. A parallel plate DOT instrument developed for breast cancer imaging is described. The system relies heavily on continuous-wave (CW) transmission measurements and utilizes frequency domain (FD) measurements on the reemission side. However, traditional DOT image reconstruction methods based on CW measurements fail to separate tissue absorption and scattering uniquely. In this manuscript, multi-spectral DOT is shown to be capable of minimizing cross-talk and retrieving spectral parameters almost uniquely when the measurement wavelengths are optimized. A theoretical framework to select optimum wavelengths is provided, and tested with computer simulations. Results from phantom spectroscopy experiments and in vivo patient measurements support the notion that multi-spectral methods are superior to traditional DOT image reconstruction schemes. The same breast DOT instrument is improved and utilized to obtain the first in vivo images of human breast cancer based on fluorescence DOT (FDOT). To this end the fluorophore Indocyanine Green (ICG) is injected intravenously and fluorescence excitation and detection are accomplished in the soft-compression, parallel-plane, transmission geometry using laser sources at 786 nm and spectrally filtered CCD detection. Careful phantom and in vivo measurements are carried on to assure that the signals are due to ICG fluorescence, rather than tissue autofluorescence and excitation light leakage. An in vivo measurement protocol is designed to maximize the ICG contrast by acquiring full fluorescence tomographic scan during

  17. Mathematical Methods in Tomography

    CERN Document Server

    Louis, Alfred; Natterer, Frank

    1991-01-01

    The conference was devoted to the discussion of present and future techniques in medical imaging, including 3D x-ray CT, ultrasound and diffraction tomography, and biomagnetic ima- ging. The mathematical models, their theoretical aspects and the development of algorithms were treated. The proceedings contains surveys on reconstruction in inverse obstacle scat- tering, inversion in 3D, and constrained least squares pro- blems.Research papers include besides the mentioned imaging techniques presentations on image reconstruction in Hilbert spaces, singular value decompositions, 3D cone beam recon- struction, diffuse tomography, regularization of ill-posed problems, evaluation reconstruction algorithms and applica- tions in non-medical fields. Contents: Theoretical Aspects: J.Boman: Helgason' s support theorem for Radon transforms-a newproof and a generalization -P.Maass: Singular value de- compositions for Radon transforms- W.R.Madych: Image recon- struction in Hilbert space -R.G.Mukhometov: A problem of in- teg...

  18. Génération d'onde stokes du second ordre et effet laser dans une fibre optique a cœur suspendu en verre de chalcogénure AsSe

    OpenAIRE

    Hey Tow , Kenny; Besnard , Pascal; Brilland , Laurent; Toupin , Périne; Troles , Johann; Méchin , David; Trégoat , Denis

    2011-01-01

    National audience; Une étude expérimentale sur les propriétés de la rétrodiffusion Brillouin stimulée dans une fibre optique à cœur suspendu en verre de chalcogénure AsSe est présentée. Avec seulement un mètre de fibre, nous générons suffisamment de gain Brillouin pour obtenir un laser à fibre monomode de type Fabry-Perot. Nous démontrons aussi la génération du second ordre Brillouin dans ces fibres avec 0,5 W de pompe.

  19. Computer tomography in the diagnosis of liver diseases

    International Nuclear Information System (INIS)

    Petkov, D.; Zhelyazkov, S.; Nedelkov, G.

    1983-01-01

    The modern achievements in the clinical study and diagnosis of liver diseases has definitely been associated with the application of whole body computer tomography (CT) in the practice. The diagnostic possibilities of the method come from high contrast and spacial disjunctive capabilities. Visualization of local lesions is associated with their size and the differences in their densitometric compactness from that of the normal parenchyma. The advantages of computer tomography in the diagnosis of liver diseases is discussed. They are associated with the possibilities for densitometric analysis of the pathologic changes, which opens a way for a probable qualitative diagnosis. Diffuse processes in the liver are relative indication for performing computer tomography. Examination under conditions of contrast amplification is indicated in cases when the nature of the lesion has to be specified and a ''negative'' result does not concur with the clinical manifestations. (authors)

  20. Quantitative assessment of diffuse optical tomography sensitivity to the cerebral cortex using a whole-head probe

    International Nuclear Information System (INIS)

    Perdue, Katherine L; Diamond, Solomon G; Fang Qianqian

    2012-01-01

    We quantify the variability in diffuse optical tomography (DOT) sensitivity over the cortical surface in eight young adult subjects. We use the 10/5 electroencephalography system as a basis for our whole-head optical high-density probe design. The contrast-to-noise ratio (CNR) is calculated along with the percentage of the cortex that is above a CNR = 0 dB threshold. We also quantify the effect of including vasculature on the forward model and list our assumptions that allow us to estimate light penetration depth in the head. We show that using the 10/5 system for the optical probe design allows for the measurement of 37% of the cortical surface on average, with a mean CNR in the visible region of 5.5 dB. Certain anatomical regions, such as the lateral occipital cortex, had a very high percentage above the CNR threshold, while other regions such as the cingulate cortex were not measurable. Vasculature blocked optical sensitivity over 1% of the cortex. Cortical coverage was positively correlated with intracranial volume and relative cerebrospinal fluid volume, and negatively correlated with relative scalp volume and skull volume. These contributions allow experimenters to understand how anatomical variation in a subject population may impact DOT or functional near-infrared spectroscopy measurements. (paper)

  1. Computed tomography in diagnosis of diffuse axonal injury

    International Nuclear Information System (INIS)

    Iwadate, Yasuo; Ono, Juniti; Okimura, Yoshitaka; Suda, Sumio; Isobe, Katsumi; Yamaura, Akira.

    1990-01-01

    Diffuse axonal injury (DAI) has been described in instances of prolonged traumatic coma on the basis of the neuropathological findings, but the same findings are also found in patients with cerebral concussion. Experimental studies confirm that the quality of survivors following trauma is directly proportional to the amount of primarily injured-axon. When the injured axon lies in a widespread area of the brain, outcome for the patient is always poor. In a series of 260 severely head-injured patients, based on their poor outcome, 69 (27%) were diagnosed as DAI. Because of their relatively good outcome, eighty-two patients (32%) were classified into non-DAI group. The predominant CT finding of DAI patients was intraparenchymal deep-seated hemorrhagic lesion. This was observed in 28 patients (41%). Normal CT was also observed in 11 patients (16%). On the other hand, 8 of the non-DAI group (10%) manifested deep-seated lesions. Diffuse cerebral swelling (DCS) appeared in both groups in the same incidence. Subarachnoid hematoma in the perimesencephalic cistern (SAH (PMC)) and intraventricular hematoma (IVH) were observed in 64% of the DAI group, and in 23% of the non-DAI group. The available evidence indicates that various types of hematoma seen in the deep-seated structures of the brain do not have an absolute diagnostic value, but the frequency of hematoma is thought to increase in proportion to the amount of injured-axon. (author)

  2. Diffuse fatty infiltration of the liver: Pitfalls in computed tomography diagnosis

    International Nuclear Information System (INIS)

    Loh, Y.H.; Dunn, G.D.

    1997-01-01

    The presence of a fatty liver often complicates the interpretation of abdominal computed tomography (CT). Abnormalities in or adjacent to the liver, including dilated bile ducts, liver masses and subphrenic collections, may be masked by the fatty liver. Furthermore, normal structures may simulate pathological conditions. Five cases are presented to illustrate some of these diagnostic pitfalls. (authors)

  3. Tropical pulmonary eosinophilia: a comparative evaluation of plain chest radiography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sandhu Manavijit; Mukhopadhyay Sima; Sharma, S.K. [All India Inst. of Medical Sciences, New Delhi (India). Dept. of Nuclear Medicine

    1996-02-01

    Plain chest radiography and computed tomography (CT) of the chest were performed on 10 patients with tropical pulmonary eosinophilia (TPE). Chest radiographs revealed bilateral diffuse lesions in the lungs of all the patients with relative sparing of lower lobes in one patient. However, computed tomography revealed bilateral diffuse lung lesions in all of the patients with relative sparing of lower lobes in three patients. In seven (70%) of the 10 patients, CT provided additional information. Computed tomography was found to be superior for the detection of reticulonodular pattern, bronchiectasis, air trapping, calcification and mediastinal adenopathy. No correlation was found between pulmonary function and gas exchange data using CT densities. There was also no correlation between the absolute eosinophil count (AEC) and the radiological severity of lesions. In six patients, high-resolution CT (HRCT) was performed in addition to conventional CT (CCT), and nodularity of lesions was better appreciated in these patients. It is concluded from this study that CT is superior to plain radiography for the evaluation of patients with TPE. 17 refs., 2 tabs., 4 figs.

  4. Fréchet derivative with respect to the shape of a strongly convex nonscattering region in optical tomography

    Science.gov (United States)

    Hyvönen, Nuutti

    2007-10-01

    The aim of optical tomography is to reconstruct the optical properties inside a physical body, e.g. a neonatal head, by illuminating it with near-infrared light and measuring the outward flux of photons on the object boundary. Because a brain consists of strongly scattering tissue with imbedded cavities filled by weakly scattering cerebrospinal fluid, propagation of near-infrared photons in the human head can be treated by combining the diffusion approximation of the radiative transfer equation with geometrical optics to obtain the radiosity-diffusion forward model of optical tomography. At the moment, a disadvantage with the radiosity-diffusion model is that the locations of the transparent cavities must be known in advance in order to be able to reconstruct the physiologically interesting quantities, i.e., the absorption and the scatter in the strongly scattering brain tissue. In this work we show that the boundary measurement map of optical tomography is Fréchet differentiable with respect to the shape of a strongly convex nonscattering region. Using this result, we introduce a numerical algorithm for approximating an unknown nonscattering cavity by a ball if the background diffuse optical properties of the object are known. The functionality of the method is demonstrated through two-dimensional numerical experiments.

  5. The value of routine bone marrow biopsy in patients with diffuse large B-cell lymphoma staged with PET/CT

    DEFF Research Database (Denmark)

    Alzahrani, M; El-Galaly, T C; Hutchings, M

    2016-01-01

    BACKGROUND: The added diagnostic and prognostic value of routine bone marrow biopsy (BMB) in patients with diffuse large B-cell lymphoma (DLBCL) undergoing positron emission tomography combined with computed tomography (PET/CT) staging is controversial. PATIENTS AND METHODS: Patients with newly d...

  6. Utility of dynamic computed tomography in diffuse liver diseases

    International Nuclear Information System (INIS)

    Fujikawa, Koichi; Inagawa, Akira; Yokoyama, Tatsushi; Iwamoto, Toshiyuki; Katayama, Hiroshi; Mori, Masaki; Ito, Katsuhide; Katsuta, Shizutomo.

    1985-01-01

    We tested the diagnostic abilities of dynamic CT in diffuse liver diseases. The material includes 23 cases of chronic active hepatitis (CAH), 32 cases of liver cirrhosis (LC) and 15 cases with normal liver. For each case, time-density curve was obtained from the right lobe of the liver. To allow numerical evaluation of the curve, gamma variate fit techniques were employed. Changes in the curves were analyzed by comparing three parameters-rise time (RT), decay time (DT) and corrected first moment (MC)-derived from two coefficients of the fitting equation. Values of three parameters increased with the severity of the diseases reflecting prolonged curves with delayed peak and gradual downslope in damaged livers. MC values showed most significant correlation with the degree of the diseases. High MC value (>95) were associated with 30 cases of LC and 3 cases of CHA, and moderate MC value (70< MC<=95) with 19 cases of CAH and 2 controls, and low MC value (<=70) with 15 controls and a case of CAH. We conclude that dynamic CT time-density study with gamma variate fitting is useful in the differential diagnosis of the diffuse liver diseases. (author)

  7. A Unique Case of Diffuse Metastatic Neuroendocrine Cancer with Subcutaneous Nodules on 18F-Fluorodeoxyglucose Positron Emission Tomography/Computer Assisted Tomography

    International Nuclear Information System (INIS)

    Johnston, Mickaila J.; Sachedina, Archana; McDonald, James E.

    2015-01-01

    Neuroendocrine tumors (NETs) account for 8–10% of cases of carcinomas of unknown primary. Most of these cases are poorly differentiated with metastatic disease at the time of diagnosis. However, cutaneous metastatic presentation is rare. We present an interesting case of a 74-year-old woman presenting with cutaneous metastatic involvement from high grade poorly differentiated NET of unknown origin. She was referred to us with a diagnosis of lymphoma. 18 F-fluorodeoxyglucose positron emission tomography/computer assisted tomography imaging at our institution offered a differential diagnosis, including neuroendocrine cancer. Repeat skin lesion biopsy demonstrated “non-Merkel cell” carcinoma, favoring metastatic high-grade neuroendocrine carcinoma

  8. Effective hydrogen diffusion coefficient for solidifying aluminium alloys

    International Nuclear Information System (INIS)

    Felberbaum, M.; Landry-Desy, E.; Weber, L.; Rappaz, M.

    2011-01-01

    An effective hydrogen diffusion coefficient has been calculated for two solidifying Al - 4.5 wt.% Cu and Al - 10 wt.% Cu alloys as a function of the volume fraction of solid. For this purpose, in situ X-ray tomography was performed on these alloys. For each volume fraction of solid between 0.6 and 0.9, a representative volume element of the microstructure was extracted. Solid and liquid voxels were assimilated to solid and liquid nodes in order to solve the hydrogen diffusion equation based on the chemical potential and using a finite volume formulation. An effective hydrogen diffusion coefficient based on the volume fraction of solid only could be deduced from the results of the numerical model at steady state. The results are compared with various effective medium theories.

  9. High-resolution computed tomography findings in pulmonary Langerhans cell histiocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Rosana Souza [Universidade Federal do Rio de Janeiro (HUCFF/UFRJ), RJ (Brazil). Hospital Universitario Clementino Fraga Filho. Unit of Radiology; Capone, Domenico; Ferreira Neto, Armando Leao [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2011-07-15

    Objective: The present study was aimed at characterizing main lung changes observed in pulmonary Langerhans cell histiocytosis by means of high-resolution computed tomography. Materials and Methods: High-resolution computed tomography findings in eight patients with proven disease diagnosed by open lung biopsy, immunohistochemistry studies and/or extrapulmonary manifestations were retrospectively evaluated. Results: Small rounded, thin-walled cystic lesions were observed in the lung of all the patients. Nodules with predominantly peripheral distribution over the lung parenchyma were observed in 75% of the patients. The lesions were diffusely distributed, predominantly in the upper and middle lung fields in all of the cases, but involvement of costophrenic angles was observed in 25% of the patients. Conclusion: Comparative analysis of high-resolution computed tomography and chest radiography findings demonstrated that thinwalled cysts and small nodules cannot be satisfactorily evaluated by conventional radiography. Because of its capacity to detect and characterize lung cysts and nodules, high-resolution computed tomography increases the probability of diagnosing pulmonary Langerhans cell histiocytosis. (author)

  10. Metabolomics of Breast Cancer Using High-Resolution Magic Angle Spinning Magnetic Resonance Spectroscopy: Correlations with 18F-FDG Positron Emission Tomography-Computed Tomography, Dynamic Contrast-Enhanced and Diffusion-Weighted Imaging MRI.

    Science.gov (United States)

    Yoon, Haesung; Yoon, Dahye; Yun, Mijin; Choi, Ji Soo; Park, Vivian Youngjean; Kim, Eun-Kyung; Jeong, Joon; Koo, Ja Seung; Yoon, Jung Hyun; Moon, Hee Jung; Kim, Suhkmann; Kim, Min Jung

    2016-01-01

    Our goal in this study was to find correlations between breast cancer metabolites and conventional quantitative imaging parameters using high-resolution magic angle spinning (HR-MAS) magnetic resonance spectroscopy (MRS) and to find breast cancer subgroups that show high correlations between metabolites and imaging parameters. Between August 2010 and December 2013, we included 53 female patients (mean age 49.6 years; age range 32-75 years) with a total of 53 breast lesions assessed by the Breast Imaging Reporting and Data System. They were enrolled under the following criteria: breast lesions larger than 1 cm in diameter which 1) were suspicious for malignancy on mammography or ultrasound (US), 2) were pathologically confirmed to be breast cancer with US-guided core-needle biopsy (CNB) 3) underwent 3 Tesla MRI with dynamic contrast-enhanced (DCE) and diffusion-weighted imaging (DWI) and positron emission tomography-computed tomography (PET-CT), and 4) had an attainable immunohistochemistry profile from CNB. We acquired spectral data by HR-MAS MRS with CNB specimens and expressed the data as relative metabolite concentrations. We compared the metabolites with the signal enhancement ratio (SER), maximum standardized FDG uptake value (SUV max), apparent diffusion coefficient (ADC), and histopathologic prognostic factors for correlation. We calculated Spearman correlations and performed a partial least squares-discriminant analysis (PLS-DA) to further classify patient groups into subgroups to find correlation differences between HR-MAS spectroscopic values and conventional imaging parameters. In a multivariate analysis, the PLS-DA models built with HR-MAS MRS metabolic profiles showed visible discrimination between high and low SER, SUV, and ADC. In luminal subtype breast cancer, compared to all cases, high SER, ADV, and SUV were more closely clustered by visual assessment. Multiple metabolites were correlated with SER and SUV in all cases. Multiple metabolites showed

  11. Metabolomics of Breast Cancer Using High-Resolution Magic Angle Spinning Magnetic Resonance Spectroscopy: Correlations with 18F-FDG Positron Emission Tomography-Computed Tomography, Dynamic Contrast-Enhanced and Diffusion-Weighted Imaging MRI.

    Directory of Open Access Journals (Sweden)

    Haesung Yoon

    Full Text Available Our goal in this study was to find correlations between breast cancer metabolites and conventional quantitative imaging parameters using high-resolution magic angle spinning (HR-MAS magnetic resonance spectroscopy (MRS and to find breast cancer subgroups that show high correlations between metabolites and imaging parameters.Between August 2010 and December 2013, we included 53 female patients (mean age 49.6 years; age range 32-75 years with a total of 53 breast lesions assessed by the Breast Imaging Reporting and Data System. They were enrolled under the following criteria: breast lesions larger than 1 cm in diameter which 1 were suspicious for malignancy on mammography or ultrasound (US, 2 were pathologically confirmed to be breast cancer with US-guided core-needle biopsy (CNB 3 underwent 3 Tesla MRI with dynamic contrast-enhanced (DCE and diffusion-weighted imaging (DWI and positron emission tomography-computed tomography (PET-CT, and 4 had an attainable immunohistochemistry profile from CNB. We acquired spectral data by HR-MAS MRS with CNB specimens and expressed the data as relative metabolite concentrations. We compared the metabolites with the signal enhancement ratio (SER, maximum standardized FDG uptake value (SUV max, apparent diffusion coefficient (ADC, and histopathologic prognostic factors for correlation. We calculated Spearman correlations and performed a partial least squares-discriminant analysis (PLS-DA to further classify patient groups into subgroups to find correlation differences between HR-MAS spectroscopic values and conventional imaging parameters.In a multivariate analysis, the PLS-DA models built with HR-MAS MRS metabolic profiles showed visible discrimination between high and low SER, SUV, and ADC. In luminal subtype breast cancer, compared to all cases, high SER, ADV, and SUV were more closely clustered by visual assessment. Multiple metabolites were correlated with SER and SUV in all cases. Multiple metabolites

  12. Temporal comparison of functional brain imaging with diffuse optical tomography and fMRI during rat forepaw stimulation

    International Nuclear Information System (INIS)

    Siegel, Andrew M; Culver, Joseph P; Mandeville, Joseph B; Boas, David A

    2003-01-01

    The time courses of oxyhaemoglobin ([HbO 2 ]), deoxyhaemoglobin ([HbR]) and total haemoglobin ([HbT]) concentration changes following cortical activation in rats by electrical forepaw stimulation were measured using diffuse optical tomography (DOT) and compared to similar measurements performed previously with fMRI at 2.0 T and 4.7 T. We also explored the qualitative effects of varying stimulus parameters on the temporal evolution of the hemodynamic response. DOT images were reconstructed at a depth of 1.5 mm over a 1 cm square area from 2 mm anterior to bregma to 8 mm posterior to bregma. The measurement set included 9 sources and 16 detectors with an imaging frame rate of 10 Hz. Both DOT [HbR] and [HbO 2 ] time courses were compared to the fMRI BOLD time course during stimulation, and the DOT [HbT] time course was compared to the fMRI cerebral plasma volume (CPV) time course. We believe that DOT and fMRI can provide similar temporal information for both blood volume and deoxyhaemoglobin changes, which helps to cross-validate these two techniques and to demonstrate that DOT can be useful as a complementary modality to fMRI for investigating the hemodynamic response to neuronal activity

  13. Temporal comparison of functional brain imaging with diffuse optical tomography and fMRI during rat forepaw stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Siegel, Andrew M [Tufts University Bioengineering Center, Medford, MA 02155 (United States); Culver, Joseph P [Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02129 (United States); Mandeville, Joseph B [Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02129 (United States); Boas, David A [Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02129 (United States)

    2003-05-21

    The time courses of oxyhaemoglobin ([HbO{sub 2}]), deoxyhaemoglobin ([HbR]) and total haemoglobin ([HbT]) concentration changes following cortical activation in rats by electrical forepaw stimulation were measured using diffuse optical tomography (DOT) and compared to similar measurements performed previously with fMRI at 2.0 T and 4.7 T. We also explored the qualitative effects of varying stimulus parameters on the temporal evolution of the hemodynamic response. DOT images were reconstructed at a depth of 1.5 mm over a 1 cm square area from 2 mm anterior to bregma to 8 mm posterior to bregma. The measurement set included 9 sources and 16 detectors with an imaging frame rate of 10 Hz. Both DOT [HbR] and [HbO{sub 2}] time courses were compared to the fMRI BOLD time course during stimulation, and the DOT [HbT] time course was compared to the fMRI cerebral plasma volume (CPV) time course. We believe that DOT and fMRI can provide similar temporal information for both blood volume and deoxyhaemoglobin changes, which helps to cross-validate these two techniques and to demonstrate that DOT can be useful as a complementary modality to fMRI for investigating the hemodynamic response to neuronal activity.

  14. Thermal diffusivity of diamond nanowires studied by laser assisted atom probe tomography

    Science.gov (United States)

    Arnoldi, L.; Spies, M.; Houard, J.; Blum, I.; Etienne, A.; Ismagilov, R.; Obraztsov, A.; Vella, A.

    2018-04-01

    The thermal properties of single-crystal diamond nanowires (NWs) have been calculated from first principles but have never been measured experimentally. Taking advantage of the sharp geometry of samples analyzed in a laser assisted atom probe, this technique is used to measure the thermal diffusivity of a single NW at low temperature (ab-initio calculations and confirms that thermal diffusivity in nanoscale samples is lower than in bulk samples. The results impact the design and integration of diamond NWs and nanoneedles in nanoscale devices for heat dissipation.

  15. Positron Emission Tomography/Computed Tomography Findings During Therapy Predict Outcome in Patients With Diffuse Large B-Cell Lymphoma Treated With Chemotherapy Alone but Not in Those Who Receive Consolidation Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Dabaja, Bouthaina S., E-mail: bdabaja@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Hess, Kenneth [Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Shihadeh, Ferial [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Podoloff, Donald A. [Department of Nuclear Medicine, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Medeiros, L. Jeffrey [Department of Hematopathology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Mawlawi, Osama [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Arzu, Isidora [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Oki, Yasuhiro; Hagemeister, Fredrick B.; Fayad, Luis E. [Department of Lymphoma/Myeloma, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Reed, Valerie K.; Kedir, Aziza; Wogan, Christine F. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Rodriguez, Alma [Office of the Executive Vice President and Physician-in-Chief, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2014-06-01

    Purpose: To assess the value of mid-therapy positron emission tomography (PET) findings for predicting survival and disease progression in patients with diffuse large B-cell lymphoma, considering type of therapy (chemotherapy with or without radiation therapy). Methods and Materials: We retrospectively evaluated 294 patients with histologically confirmed diffuse large B-cell lymphoma with respect to age, sex, disease stage, International Prognostic Index score, mid-therapy PET findings (positive or negative), and disease status after therapy and at last follow-up. Overall survival (OS) and progression-free survival (PFS) were compared according to mid-therapy PET findings. Results: Of the 294 patients, 163 (55%) were male, 144 (49%) were age >61 years, 110 (37%) had stage I or II disease, 219 (74%) had International Prognostic Index score ≤2, 216 (73%) received ≥6 cycles of rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone, and 88 (30%) received consolidation radiation therapy. Five-year PFS and OS rates were associated with mid-therapy PET status: PFS was 78% for those with PET-negative (PET−) disease versus 63% for PET-positive (PET+) disease (P=.024), and OS was 82% for PET− versus 62% for PET+ (P<.002). These associations held true for patients who received chemotherapy only (PFS 71% for PET− vs 52% PET+ [P=.012], OS 78% for PET− and 51% for PET+ [P=.0055]) but not for those who received consolidation radiation therapy (PFS 84% PET− vs 81% PET+ [P=.88]; OS 90% PET− vs 81% PET+ [P=.39]). Conclusion: Mid-therapy PET can predict patient outcome, but the use of consolidation radiation therapy may negate the significance of mid-therapy findings.

  16. A surgical navigation system for non-contact diffuse optical tomography and intraoperative cone-beam CT

    Science.gov (United States)

    Daly, Michael J.; Muhanna, Nidal; Chan, Harley; Wilson, Brian C.; Irish, Jonathan C.; Jaffray, David A.

    2014-02-01

    A freehand, non-contact diffuse optical tomography (DOT) system has been developed for multimodal imaging with intraoperative cone-beam CT (CBCT) during minimally-invasive cancer surgery. The DOT system is configured for near-infrared fluorescence imaging with indocyanine green (ICG) using a collimated 780 nm laser diode and a nearinfrared CCD camera (PCO Pixelfly USB). Depending on the intended surgical application, the camera is coupled to either a rigid 10 mm diameter endoscope (Karl Storz) or a 25 mm focal length lens (Edmund Optics). A prototype flatpanel CBCT C-Arm (Siemens Healthcare) acquires low-dose 3D images with sub-mm spatial resolution. A 3D mesh is extracted from CBCT for finite-element DOT implementation in NIRFAST (Dartmouth College), with the capability for soft/hard imaging priors (e.g., segmented lymph nodes). A stereoscopic optical camera (NDI Polaris) provides real-time 6D localization of reflective spheres mounted to the laser and camera. Camera calibration combined with tracking data is used to estimate intrinsic (focal length, principal point, non-linear distortion) and extrinsic (translation, rotation) lens parameters. Source/detector boundary data is computed from the tracked laser/camera positions using radiometry models. Target registration errors (TRE) between real and projected boundary points are ~1-2 mm for typical acquisition geometries. Pre-clinical studies using tissue phantoms are presented to characterize 3D imaging performance. This translational research system is under investigation for clinical applications in head-and-neck surgery including oral cavity tumour resection, lymph node mapping, and free-flap perforator assessment.

  17. Acinar cell carcinoma of the pancreas presenting as diffuse pancreatic enlargement: Two case reports and literature review.

    Science.gov (United States)

    Luo, Yaping; Hu, Guilan; Ma, Yanru; Guo, Ning; Li, Fang

    2017-09-01

    Pancreatic acinar cell carcinoma (ACC) is a rare malignant tumor of exocrine pancreas. It is typically a well-marginated large solid mass arising in a certain aspect of the pancreas. Diffuse involvement of ACC in the pancreas is very rare, and may simulate pancreatitis in radiological findings. We report 2 cases of ACC presenting as diffuse enlargement of the pancreas due to tumor involvement without formation of a distinct mass. The patients consisted of a 41-year-old man with weight loss and a 77-year-old man who was asymptomatic. Computed tomography (CT) and 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT showed diffuse enlargement of the pancreas forming a sausage-like shape with homogenously increased FDG activity. Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) biopsy of the pancreatic lesion was performed. Histopathology results from the pancreas confirmed the diagnosis of pancreatic ACC. Because diffuse enlargement of the pancreas is a common imaging feature of pancreatitis, recognition of this rare morphologic pattern of ACC is important for radiological diagnosis of this tumor.

  18. CT of diffuse pulmonary diseases

    International Nuclear Information System (INIS)

    Itoh, Harumi; Murata, Kiyoshi; Todo, Giro

    1987-01-01

    While the theory of chest radiographic interpretation in diagnosing diffuse pulmonary diseases has not yet been established, X-ray computed tomography (CT), having intrinsic high contrast resolution and improved spatial resolution, has proved to offer important imformation concerning the location and invasion of diffuse pulmonary lesions. This study related to CT-pathologic correlation, focusing on perivascular interstitial space and secondary pulmonary lobule at macroscopic levels. The perivascular interstitial space was thickened as a result of the infiltration of cancer, granulomas, and inflammatory cells. This finding appeared as irregular contour of the blood vessel on CT. Centrilobular nodules were distributed at the tip of the bronchus or pulmonary artery on CT. The distance from the terminal and respiratory bronchioles to the lobular border was 2 to 3 mm. Lobular lesions were delineated as clear margin on CT. Contribution of these CT features to chest radiographic interpretation must await further studies. (Namekawa, K.)

  19. Morpho-functional evaluation of torpedo maculopathy with optical coherence tomography angiography and microperimetry

    Directory of Open Access Journals (Sweden)

    Gabriela Grimaldi

    2018-06-01

    Full Text Available Purpose: To report the case of a 13-year-old girl with torpedo maculopathy, evaluated with multimodal morpho-functional retinal imaging, including fundus photography, infra-red and blue fundus autofluorescence, swept-source optical coherence tomography (OCT, en face OCT, OCT angiography and microperimetry (MP. Observations: On fundus examination, a torpedo-like hypopigmented lesion was observed temporal to the fovea in the left eye. OCT showed disruption of outer retinal layers and the presence of a subretinal cleft. On OCTA, a diffuse attenuation of signal from choriocapillaris was observed along the lesion. Functional analysis with MP revealed a reduction of retinal sensitivity over the lesion. Conclusions: and importance: On OCTA, torpedo maculopathy is characterized by vascular alterations of the choriocapillaris along the lesion. Keywords: Optical coherence tomography angiography, Torpedo maculopathy, Microperimetry, Swept-source optical coherence tomography, En face optical coherence tomography

  20. Cervical Gross Tumor Volume Dose Predicts Local Control Using Magnetic Resonance Imaging/Diffusion-Weighted Imaging—Guided High-Dose-Rate and Positron Emission Tomography/Computed Tomography—Guided Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Dyk, Pawel; Jiang, Naomi; Sun, Baozhou; DeWees, Todd A. [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Fowler, Kathryn J.; Narra, Vamsi [Department of Diagnostic Radiology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri (United States); Garcia-Ramirez, Jose L.; Schwarz, Julie K. [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Grigsby, Perry W., E-mail: pgrigsby@wustl.edu [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Division of Nuclear Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri (United States); Division of Gynecologic Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri (United States); Alvin J. Siteman Cancer Center, Washington University School of Medicine, St Louis, Missouri (United States)

    2014-11-15

    Purpose: Magnetic resonance imaging/diffusion weighted-imaging (MRI/DWI)-guided high-dose-rate (HDR) brachytherapy and {sup 18}F-fluorodeoxyglucose (FDG) — positron emission tomography/computed tomography (PET/CT)-guided intensity modulated radiation therapy (IMRT) for the definitive treatment of cervical cancer is a novel treatment technique. The purpose of this study was to report our analysis of dose-volume parameters predicting gross tumor volume (GTV) control. Methods and Materials: We analyzed the records of 134 patients with International Federation of Gynecology and Obstetrics stages IB1-IVB cervical cancer treated with combined MRI-guided HDR and IMRT from July 2009 to July 2011. IMRT was targeted to the metabolic tumor volume and lymph nodes by use of FDG-PET/CT simulation. The GTV for each HDR fraction was delineated by use of T2-weighted or apparent diffusion coefficient maps from diffusion-weighted sequences. The D100, D90, and Dmean delivered to the GTV from HDR and IMRT were summed to EQD2. Results: One hundred twenty-five patients received all irradiation treatment as planned, and 9 did not complete treatment. All 134 patients are included in this analysis. Treatment failure in the cervix occurred in 24 patients (18.0%). Patients with cervix failures had a lower D100, D90, and Dmean than those who did not experience failure in the cervix. The respective doses to the GTV were 41, 58, and 136 Gy for failures compared with 67, 99, and 236 Gy for those who did not experience failure (P<.001). Probit analysis estimated the minimum D100, D90, and Dmean doses required for ≥90% local control to be 69, 98, and 260 Gy (P<.001). Conclusions: Total dose delivered to the GTV from combined MRI-guided HDR and PET/CT-guided IMRT is highly correlated with local tumor control. The findings can be directly applied in the clinic for dose adaptation to maximize local control.

  1. DWI-ASPECTS (Diffusion-Weighted Imaging-Alberta Stroke Program Early Computed Tomography Scores) and DWI-FLAIR (Diffusion-Weighted Imaging-Fluid Attenuated Inversion Recovery) Mismatch in Thrombectomy Candidates: An Intrarater and Interrater Agreement Study.

    Science.gov (United States)

    Fahed, Robert; Lecler, Augustin; Sabben, Candice; Khoury, Naim; Ducroux, Célina; Chalumeau, Vanessa; Botta, Daniele; Kalsoum, Erwah; Boisseau, William; Duron, Loïc; Cabral, Dominique; Koskas, Patricia; Benaïssa, Azzedine; Koulakian, Hasmik; Obadia, Michael; Maïer, Benjamin; Weisenburger-Lile, David; Lapergue, Bertrand; Wang, Adrien; Redjem, Hocine; Ciccio, Gabriele; Smajda, Stanislas; Desilles, Jean-Philippe; Mazighi, Mikaël; Ben Maacha, Malek; Akkari, Inès; Zuber, Kevin; Blanc, Raphaël; Raymond, Jean; Piotin, Michel

    2018-01-01

    We aimed to study the intrarater and interrater agreement of clinicians attributing DWI-ASPECTS (Diffusion-Weighted Imaging-Alberta Stroke Program Early Computed Tomography Scores) and DWI-FLAIR (Diffusion-Weighted Imaging-Fluid Attenuated Inversion Recovery) mismatch in patients with acute ischemic stroke referred for mechanical thrombectomy. Eighteen raters independently scored anonymized magnetic resonance imaging scans of 30 participants from a multicentre thrombectomy trial, in 2 different reading sessions. Agreement was measured using Fleiss κ and Cohen κ statistics. Interrater agreement for DWI-ASPECTS was slight (κ=0.17 [0.14-0.21]). Four raters (22.2%) had a substantial (or higher) intrarater agreement. Dichotomization of the DWI-ASPECTS (0-5 versus 6-10 or 0-6 versus 7-10) increased the interrater agreement to a substantial level (κ=0.62 [0.48-0.75] and 0.68 [0.55-0.79], respectively) and more raters reached a substantial (or higher) intrarater agreement (17/18 raters [94.4%]). Interrater agreement for DWI-FLAIR mismatch was moderate (κ=0.43 [0.33-0.57]); 11 raters (61.1%) reached a substantial (or higher) intrarater agreement. Agreement between clinicians assessing DWI-ASPECTS and DWI-FLAIR mismatch may not be sufficient to make repeatable clinical decisions in mechanical thrombectomy. The dichotomization of the DWI-ASPECTS (0-5 versus 0-6 or 0-6 versus 7-10) improved interrater and intrarater agreement, however, its relevance for patients selection for mechanical thrombectomy needs to be validated in a randomized trial. © 2017 American Heart Association, Inc.

  2. Diffuse Type Primary Mycobacterium Tuberculosis of the Breast: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun A; Kang, Bong Joo; Kim, Sung Hun; Kim, Hnana; Lee, Ah Won [Seoul St. Mary' s Hospital, The Catholic University of Korea, Seoul (Korea, Republic of)

    2011-12-15

    Tuberculous mastitis is a rare manifestation of mycobacterium tuberculosis infection. It mimics inflammatory breast cancer or other pyogenic inflammations. In most of the tuberculous mastitis reports, coexisting or prior tuberculosis infection and secondary infection of the breast by direct spread via axillary or cervical lymphadenopathy, or hematogenous spread have been noted. We describe the mammographic and ultrasonographic findings of a case of diffuse type mycobacterium tuberculosis of the breast showing diffuse edema which was confirmed as tuberculosis through biopsy and had no evidence of old or concurrent pulmonary tuberculosis on chest computed tomography

  3. Diffuse and diffuse-plus-focal uptake in the thyroid gland identified by using FDG-PET. Prevalence of thyroid cancer and Hashimoto's thyroiditis

    International Nuclear Information System (INIS)

    Kurata, Seiji; Ishibashi, Masatoshi; Hiromatsu, Yuji; Kaida, Hayato; Miyake, Ikuyo; Uchida, Masafumi; Hayabuchi, Naofumi

    2007-01-01

    The objective of this study was to investigate and evaluate the prevalence of incidental thyroid diffuse and diffuse-plus-focal fluorine-18 fluorodeoxyglucose (FDG) uptake in healthy subjects who underwent cancer screening on positron emission tomography (PET) scan, and also to evaluate the prevalence of thyroid cancer and Hashimoto's thyroiditis. We carried out a retrospective review of 1626 subjects who underwent PET scanning at our institution. Diffuse uptake was defined as FDG uptake in the whole thyroid gland, whereas diffuse-plus-focal uptake was defined as a thyroid lesion with both diffuse uptake and focal FDG uptake. The maximum standardized uptake value of the thyroid lesions was recorded and reviewed. In each selected subject with positive thyroid FDG uptake, serum thyroid-stimulating hormone, thyroid hormone, and thyroid antibodies were measured. Fine needle aspiration cytology was performed on patients with a definite nodule using ultrasonography. Twenty-nine subjects (1.78%) were identified as having either diffuse FDG uptake (n=25, 1.53%) or diffuse-plus-focal FDG uptake (n=4, 0.24%). All subjects with diffuse FDG uptake were diagnosed as having Hashimoto's thyroiditis. In 1 of the 25 subjects with diffuse FDG uptake and two of the four with diffuse-plus-focal FDG uptake, histopathologic diagnosis showed papillary thyroid carcinoma associated with Hashimoto's thyroiditis. However, PET scan did not detect papillary carcinoma associated with Hashimoto's thyroiditis in one of the three subjects. Our results suggest that although diffuse FDG uptake usually indicates Hashimoto's thyroiditis, the risk of thyroid cancer must be recognized in both diffuse FDG uptake and diffuse-plus-focal FDG uptake on PET scan. (author)

  4. Cases of diffusely increased 18F FDG uptake in bone marrow

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Matsunaga, Naofumi

    2009-01-01

    A whole body imaging of 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT provides assessment of FDG uptake in bone marrow and other systemic organs. Diffuse increase of FDG uptake in bone marrow can be associated with leukocytosis, infection, anemia, administration of granulocyte-colony stimulating factor or erythropoietin. and cytokine-producing neoplasms and myeloproliferative syndromes, and etc, and this finding can be an important sign indicative of hyper-metabolism in hemopoietic tissue associated by various etiology. Diffuse increase of FDG uptake in bone marrow affect on FDG uptake in other organs or primary lesions, and must be differentiated from diffuse bone marrow involvement of malignant tumors. In this paper, we report cases of diffuse increase of FDG uptake in bone marrow experienced in our hospital, and discuss the mechanisms and diagnostic importance of this finding, by referring to the published literatures. (author)

  5. Cranial computed tomography in maple syrup urine disease

    International Nuclear Information System (INIS)

    Irnberger, T.; Ploechl, E.; Rittinger, O.; Bachmann, C.; Pilz, P.; Walter, G.F.; Wendel, U.; Landeskrankenanstalten Salzburg; Bern Univ.; Landesnervenklinik Salzburg; Graz Univ.; Dudley Observatory, Albany, NY; Duesseldorf Univ.

    1986-01-01

    Cranial computed tomography in the initial stage of the intermediate phenotype of maple syrup urine disease (MSUD) demonstrates diffuse, symmetric hypodensities in white and grey matter, which show a complete return to normal after early introduction of an adequate protein-restrictive diet. If diagnosis of this disease is missed or delayed, progressive global (end-stage) atrophy will take place over several years. A decrease in density values correlates well with the total cerebral lipid and water content (closely related to myelinisation), whereas progression and grade of atrophy show a relationship with the severity of pathological white and grey matter changes that are not demonstrable with computed tomography but can be proven histologically. Analysis of both morphological parameters corresponds well with clinical-neurological outcome and therapeutic success. (orig.) [de

  6. Computerized abdominal tomography in Wilson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchikura, Keiko; Ogawa, Teruyuki; Nakajima, Akihisa; Ono, Yasuhiko

    1986-05-01

    Cranial and abdominal computerized tomography (CT) was performed in a 10-year-old boy with Wilson's disease complicated by liver cirrhosis. Abdominal CT showed diffuse high density areas over the whole part of the liver propably due to copper sediments, although there was no abnormal cranial CT findings. Decreased high density area of the liver was seen 60 days after the administration of D-penicillamine, suggesting the excretion of copper from the liver. Abdominal CT, as well as cranial CT, may be of help to diagnose Wilson's disease and evaluate therapeutic effects. (Namekawa, K.).

  7. Computed tomography in neuronal ceroid lipofuscinosis

    International Nuclear Information System (INIS)

    Valavanis, A.; Schubiger, O.; Hayek, J.; Friede, R.L

    1981-01-01

    The computed tomography (CT) findings in a verified case of neutronal ceroid lipofuscinosis (NCL) are presented. CT revealed diffuse and severe cerebral atrophy, reflected by generalized subarachnoid space enlargement and symmetric ventricular dilatation. There was no evidence of abnormalities of the white matter. The CT features in our case of NCL correspond perfectly with the neuropathologic changes of the disease mentioned in the literature. Furthermore, CT is of considerable help in differentiating between those inherited metabolic brain diseases characterized primarily by white matter involvement and those presenting predominantly with changes of grey matter. (orig.) [de

  8. US-guided diffuse optical tomography for breast lesions: the reliability of clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Jung; Kim, Ji Youn; Youn, Jung Hyun; Kim, Myung Hyun; Koo, Hye Ryoung; Kim, Soo Jin; Sohn, Yu-Mee; Moon, Hee Jung; Kim, Eun-Kyung [Yonsei University College of Medicine, Institute of Radiological Science, Seoul (Korea, Republic of); Yonsei University College of Medicine, Department of Radiology, Seoul (Korea, Republic of)

    2011-07-15

    To prospectively assess the reliability of US-guided diffuse optical tomography (US-DOT) using interobserver agreement for the diagnosis of breast lesions with individual real-time imaging and to assess the interobserver agreement of conventional sonography (US) combined with US-DOT for differentiation between benignity and malignancy breast lesions. An Institutional Review Board approved this study, and all subjects provided written informed consent. 122 breast lesions in 111 patients evaluated with US-guided core biopsy were included. Assessments with US and US-DOT for cases subjected to biopsy were obtained by two radiologists using individual real-time imaging prior to biopsy and were prospectively recorded by each performer. With DOT, the total haemoglobin concentration (THC) for each breast lesion was measured. Histopathological results from US-guided biopsies were used as a reference standard. To assess measurement interobserver agreement, the intraclass correlation coefficient (ICC) and the Bland-Altman plot were used for THC in US-DOT and the kappa values and ROC analysis were used to evaluate the diagnostic performances of the US BI-RADS final assessment in US and combined US and US-DOT. Of 122 US-guided core biopsied lesions, 83 (68.0%) were diagnosed as benign, and 39 (32.0%) as malignant. Excellent correlation was seen in the THC in US-DOT (ICC score 0.796; 95% confidence interval, 0.708-0.857). The interobserver agreement in BI-RADS final assessment with US and US-DOT (almost perfect; {kappa} = 0.8618) was improved compared with that of US (substantial agreement, {kappa} = 0.6574). However, the overall areas under the ROC curve did not show significant differences between US and combined US and US-DOT, 0.8894 and 0.8975, respectively (P = 0.981). The reliability of THC in US-DOT showed excellent correlation in overall real-time performance. Although the inter-observer agreement for BI-RADS final assessment of US was improved by using US-DOT, the

  9. Diffusion-sensitive optical coherence tomography for real-time monitoring of mucus thinning treatments

    Science.gov (United States)

    Blackmon, Richard L.; Kreda, Silvia M.; Sears, Patrick R.; Ostrowski, Lawrence E.; Hill, David B.; Chapman, Brian S.; Tracy, Joseph B.; Oldenburg, Amy L.

    2016-03-01

    Mucus hydration (wt%) has become an increasingly useful metric in real-time assessment of respiratory health in diseases like cystic fibrosis and COPD, with higher wt% indicative of diseased states. However, available in vivo rheological techniques are lacking. Gold nanorods (GNRs) are attractive biological probes whose diffusion through tissue is sensitive to the correlation length of comprising biopolymers. Through employment of dynamic light scattering theory on OCT signals from GNRs, we find that weakly-constrained GNR diffusion predictably decreases with increasing wt% (more disease-like) mucus. Previously, we determined this method is robust against mucus transport on human bronchial epithelial (hBE) air-liquid interface cultures (R2=0.976). Here we introduce diffusion-sensitive OCT (DS-OCT), where we collect M-mode image ensembles, from which we derive depth- and temporally-resolved GNR diffusion rates. DS-OCT allows for real-time monitoring of changing GNR diffusion as a result of topically applied mucus-thinning agents, enabling monitoring of the dynamics of mucus hydration never before seen. Cultured human airway epithelial cells (Calu-3 cell) with a layer of endogenous mucus were doped with topically deposited GNRs (80x22nm), and subsequently treated with hypertonic saline (HS) or isotonic saline (IS). DS-OCT provided imaging of the mucus thinning response up to a depth of 600μm with 4.65μm resolution, over a total of 8 minutes in increments of >=3 seconds. For both IS and HS conditions, DS-OCT captured changes in the pattern of mucus hydration over time. DS-OCT opens a new window into understanding mechanisms of mucus thinning during treatment, enabling real-time efficacy feedback needed to optimize and tailor treatments for individual patients.

  10. Noninvasive photoacoustic computed tomography of mouse brain metabolism in vivo

    OpenAIRE

    Yao, Junjie; Xia, Jun; Maslov, Konstantin I.; Nasiriavanaki, Mohammadreza; Tsytsarev, Vassiliy; Demchenko, Alexei V.; Wang, Lihong V.

    2012-01-01

    We have demonstrated the feasibility of imaging mouse brain metabolism using photoacoustic computed tomography (PACT), a fast, noninvasive and functional imaging modality with optical contrast and acoustic resolution. Brain responses to forepaw stimulations were imaged transdermally and transcranially. 2-NBDG, which diffuses well across the blood–brain-barrier, provided exogenous contrast for photoacoustic imaging of glucose response. Concurrently, hemoglobin provided endogenous contrast for ...

  11. Single photon emission computed tomography in AIDS dementia complex

    International Nuclear Information System (INIS)

    Pohl, P.; Vogl, G.; Fill, H.; Roessler, H.Z.; Zangerle, R.; Gerstenbrand, F.

    1988-01-01

    Single photon emission computed tomography (SPECT) studies were performed in AIDS dementia complex using IMP in 12 patients (and HM-PAO in four of these same patients). In all patients, SPECT revealed either multiple or focal uptake defects, the latter corresponding with focal signs or symptoms in all but one case. Computerized tomography showed a diffuse cerebral atrophy in eight of 12 patients, magnetic resonance imaging exhibited changes like atrophy and/or leukoencephalopathy in two of five cases. Our data indicate that both disturbance of cerebral amine metabolism and alteration of local perfusion share in the pathogenesis of AIDS dementia complex. SPECT is an important aid in the diagnosis of AIDS dementia complex and contributes to the understanding of the pathophysiological mechanisms of this disorder

  12. The use of polarized deuterons beams and the determination of the optical model parameters; Utilisation de faisceaux de deutons polarises et determination des parametres du modele optique

    Energy Technology Data Exchange (ETDEWEB)

    Raynal, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-15

    entraine des relations entre les parametres adoptes. Les limitations de ces parametres sont etudiees specialement dans le cas d'un faisceau de particules de spin 1 ayant un plan de symetrie. Les reactions nucleaires a deux corps sont decrites dans le formalisme de l'helicite. A l'aide des coefficients de polarisation adoptes, on etudie la polarisation dans l'etat final avec etat initial polarise. Un potentiel optique pour deutons pout comprendre une partie scalaire, un couplage L.S et des potentiels tensoriels formes avec la distance du deuton au noyau, son moment angulaire ou son impulsion relative. Des calculs ont ete faits avec les deux premieres sortes de potentiels tensoriels. Plusieurs auteurs ont calcule un potentiel pour deutons a partir du modele optique nucleon oyau. Ces calculs sont repris en considerant l'onde S et l'onde D du deuton. Les differentes parties du potentiel ont ete calculees avec plusieurs fonctions d'onde intrinseque. L'utilisation de potentiels non uniquement scalaires permet d'obtenir de bons accords pour la section efficace avec des rayons nucleaires plus eleves que ceux necessaires avec un potentiel purement central. Les mesures experimentales de polarisation faites a Saclay pour la diffusion elastique de deutons sur le calcium sont en desaccord avec l'existence d'un potentiel tensoriel important ; elles peuvent etre reproduites en utilisant un couplage L.S. independant du potentiel central, mais avec des rayons tres faibles. (auteur)

  13. Mycosis fungoides: Positron emission tomography/computed tomography in staging and monitoring the effect of therapy

    International Nuclear Information System (INIS)

    D’Souza, Maria Mathew; D’Souza, Paschal; Sharma, Rajnish; Jaimini, Abhinav; Mondal, Anupam

    2015-01-01

    A 58-year-old woman, diagnosed as a case of mycosis fungoides (MF), underwent [18F]-fluoro-D-glucose positron emission tomography/computed tomography (FDG PET/CT) examination. The study revealed intense FDG uptake in a large ulceroproliferative right thigh lesion, indurated plaques in the chest wall and left thigh, along with multiple sites of cutaneous involvement, axillary and inguinal lymphadenopathy. The patient underwent chemotherapy with CHOP regimen, radiotherapy for the right thigh lesion, along with topical corticosteroids and emollients for the disseminated cutaneous involvement. Repeat [18F]-FDG PET/CT study performed a year later, showed near complete disease regression specifically of the ulceroproliferative lesion and indurated cutaneous plaques, no change in lymphadenopathy, and a subtle diffuse progression of the remaining cutaneous lesions. A multidisciplinary approach to the diagnosis, staging and treatment of MF has long been suggested for optimizing outcomes from management of patients with this disease. This case highlights the potential role of incorporating PET/CT as a single modality imaging technique in the staging and assessment of response to therapy

  14. ‘Double cortex’ sign on FDG-PET/CT in diffuse band heterotopia

    International Nuclear Information System (INIS)

    Tripathi, Madhavi; Tripathi, Manjari; Kumar, Ganesh; Malhotra, Arun; Bal, Chandra Sekhar

    2013-01-01

    F-18 Fluorodeoxyglucose (FDG) Positron emission tomography/Computed Tomography (PET/CT) has come to play an increasingly important role for the pre-surgical evaluation of drug resistant epilepsy and complements Magnetic Resonance Imaging (MRI) in the evaluation of grey matter heterotopias. This case illustrates the characteristic pattern of metabolic abnormality in diffuse band heterotopia (DBH) which is otherwise called double cortex syndrome. The presence of metabolic activity in the heterotopic inner cortical band and in the overlying true cortex gives rise to the ‘double cortex’ sign on FDG-PET, concurrent CT provides a good anato-metabolic coregistration

  15. ‘Double cortex’ sign on FDG-PET/CT in diffuse band heterotopia

    Science.gov (United States)

    Tripathi, Madhavi; Tripathi, Manjari; Kumar, Ganesh; Malhotra, Arun; Bal, Chandra Sekhar

    2013-01-01

    F-18 Fluorodeoxyglucose (FDG) Positron emission tomography/Computed Tomography (PET/CT) has come to play an increasingly important role for the pre-surgical evaluation of drug resistant epilepsy and complements Magnetic Resonance Imaging (MRI) in the evaluation of grey matter heterotopias. This case illustrates the characteristic pattern of metabolic abnormality in diffuse band heterotopia (DBH) which is otherwise called double cortex syndrome. The presence of metabolic activity in the heterotopic inner cortical band and in the overlying true cortex gives rise to the ‘double cortex’ sign on FDG-PET, concurrent CT provides a good anato-metabolic coregistration. PMID:24379541

  16. Whole-head functional brain imaging of neonates at cot-side using time-resolved diffuse optical tomography

    Science.gov (United States)

    Dempsey, Laura A.; Cooper, Robert J.; Powell, Samuel; Edwards, Andrea; Lee, Chuen-Wai; Brigadoi, Sabrina; Everdell, Nick; Arridge, Simon; Gibson, Adam P.; Austin, Topun; Hebden, Jeremy C.

    2015-07-01

    We present a method for acquiring whole-head images of changes in blood volume and oxygenation from the infant brain at cot-side using time-resolved diffuse optical tomography (TR-DOT). At UCL, we have built a portable TR-DOT device, known as MONSTIR II, which is capable of obtaining a whole-head (1024 channels) image sequence in 75 seconds. Datatypes extracted from the temporal point spread functions acquired by the system allow us to determine changes in absorption and reduced scattering coefficients within the interrogated tissue. This information can then be used to define clinically relevant measures, such as oxygen saturation, as well as to reconstruct images of relative changes in tissue chromophore concentration, notably those of oxy- and deoxyhaemoglobin. Additionally, the effective temporal resolution of our system is improved with spatio-temporal regularisation implemented through a Kalman filtering approach, allowing us to image transient haemodynamic changes. By using this filtering technique with intensity and mean time-of-flight datatypes, we have reconstructed images of changes in absorption and reduced scattering coefficients in a dynamic 2D phantom. These results demonstrate that MONSTIR II is capable of resolving slow changes in tissue optical properties within volumes that are comparable to the preterm head. Following this verification study, we are progressing to imaging a 3D dynamic phantom as well as the neonatal brain at cot-side. Our current study involves scanning healthy babies to demonstrate the quality of recordings we are able to achieve in this challenging patient population, with the eventual goal of imaging functional activation and seizures.

  17. Relationship between pretreatment FDG-PET and diffusion-weighted MRI biomarkers in diffuse large B-cell lymphoma

    Science.gov (United States)

    de Jong, Antoinette; Kwee, Thomas C; de Klerk, John MH; Adam, Judit A; de Keizer, Bart; Fijnheer, Rob; Kersten, Marie José; Ludwig, Inge; Jauw, Yvonne WS; Zijlstra, Josée M; den Bos, Indra C Pieters - Van; Stoker, Jaap; Hoekstra, Otto S; Nievelstein, Rutger AJ

    2014-01-01

    The purpose of this study was to determine the correlation between the 18F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) standardized uptake value (SUV) and the diffusion-weighted magnetic resonance imaging (MRI) apparent diffusion coefficient (ADC) in newly diagnosed diffuse large B-cell lymphoma (DLBCL). Pretreatment FDG-PET and diffusion-weighted MRI of 21 patients with histologically proven DLBCL were prospectively analyzed. In each patient, maximum, mean and peak standardized uptake value (SUV) was measured in the lesion with visually highest FDG uptake and in the largest lesion. Mean ADC (ADCmean, calculated with b-values of 0 and 1000 s/mm2) was measured in the same lesions. Correlations between FDG-PET metrics (SUVmax, SUVmean, SUVpeak) and ADCmean were assessed using Pearson’s correlation coefficients. In the lesions with visually highest FDG uptake, no significant correlations were found between the SUVmax, SUVmean, SUVpeak and the ADCmean (P=0.498, P=0.609 and P=0.595, respectively). In the largest lesions, there were no significant correlations either between the SUVmax, SUVmean, SUVpeak and the ADCmean (P=0.992, P=0.843 and P=0.894, respectively). The results of this study indicate that the glycolytic rate as measured by FDG-PET and changes in water compartmentalization and water diffusion as measured by the ADC are independent biological phenomena in newly diagnosed DLBCL. Further studies are warranted to assess the complementary roles of these different imaging biomarkers in the evaluation and follow-up of DLBCL. PMID:24795837

  18. Emission tomography: quantitative aspects in metabolic and physiopathologic studies

    International Nuclear Information System (INIS)

    Yerouchalmi-Soussaline, F.

    1984-11-01

    This thesis presents instrumental and data processing studies developped in emission tomography in man, using gamma and positron emitting tracers. High contrast visualisation of volume distribution of tracers in the organs, kinetic studies and measurements of radioactive concentration or of other clinical parameters necessitate a detailed analysis of all physical factors limiting the accuracy of the measure; therefore, development of adapted imaging devices and data processing techniques, together with models describing correctly the phenomena under study are to be carried out. Thus, in single photon (gamma) emission tomography an image reconstruction strategy is elaborated, based on an analytical model for the ill-posed problem including the attenuation effect. In positron emission tomography, the time-of-flight information combined with the reconstruction technique is used in the design of a first prototype imaging device which performance is presented and evaluated in a clinical environment. Moreover, a priori or a posteriori techniques correcting for Compton diffusion events, limited statistics and limited resolutions, are proposed and discussed for the improvement of regional measurement accuracy, in metabolic and physiopathologic studies [fr

  19. Joint project of the international network of agencies for health technology assessment--Part 1: Survey results on diffusion, assessment, and clinical use of positron emission tomography.

    Science.gov (United States)

    Hastings, John; Adams, Elizabeth J

    2006-01-01

    The International Network of Agencies for Health Technology Assessment (INAHTA) has been tracking activities associated with the clinical use of positron emission tomography (PET) in its members' healthcare systems since 1997 and published its first Joint Project report on PET in 1999. Part 1 of this Joint Project report presents survey results on diffusion, assessment activities, and policy for clinical use related to PET among INAHTA members since 1999. INAHTA members were surveyed in 2003-2004. Twenty-seven INAHTA agencies (69 percent response rate) from nineteen countries responded to the survey. Dedicated PET systems are the most universally installed systems to date. Mobile scanners and modified gamma cameras are used occasionally as lower cost alternatives, and interest in PET-computed tomography hybrid models is rising despite limited assessment of impact on service planning. PET was used and assessed most commonly for managing patients with cancer. All respondents reported having some form of public funding for clinical PET frequently linked to data collection for the purpose of gathering evidence to refine clinical use and guide resource allocation toward indications that maximize clinical and cost-effectiveness. The use of HTA within a continuous quality improvement framework can help optimize scarce resources for evaluation and use of high cost diagnostic technologies such as PET, particularly where potential clinical or cost-effectiveness is considerable but conclusive evidence is lacking.

  20. Classification of the pattern of pulmonary involvement by computed tomography in patients with non-Hodgkin's lymphoma

    International Nuclear Information System (INIS)

    Fujita, Jiro; Nagai, Masami; Nakamura, Hiroyuki

    1990-01-01

    The diagnostic value of computed tomography (CT) was assessed in 17 patients with non-Hodgkin's lymphoma. CT was performed to evaluate the localization and types of pulmonary involvement caused by non-Hodgin's lymphoma. Using CT, it was possible to classify types of pulmonary involvements as hilar and/or mediastinum-nodular (13 cases), hilar and/or mediastinum-diffuse (4 cases), pleural effusion (5 cases), parenchymal-diffuse (1 case), and parenchymal-tumor (1 case). The pattern of hilar and/or mediastinum-diffuse seemed to be specific for lymphoblastic lymphoma. CT is useful to distinguish hilar and/or mediastinum-nodular to hilar and/or mediastinum-diffuse, and to provide better definition of the specific anatomic location of pulmonary involvements. (author)

  1. Derivation of site-specific relationships between hydraulic parameters and p-wave velocities based on hydraulic and seismic tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brauchler, R.; Doetsch, J.; Dietrich, P.; Sauter, M.

    2012-01-10

    In this study, hydraulic and seismic tomographic measurements were used to derive a site-specific relationship between the geophysical parameter p-wave velocity and the hydraulic parameters, diffusivity and specific storage. Our field study includes diffusivity tomograms derived from hydraulic travel time tomography, specific storage tomograms, derived from hydraulic attenuation tomography, and p-wave velocity tomograms, derived from seismic tomography. The tomographic inversion was performed in all three cases with the SIRT (Simultaneous Iterative Reconstruction Technique) algorithm, using a ray tracing technique with curved trajectories. The experimental set-up was designed such that the p-wave velocity tomogram overlaps the hydraulic tomograms by half. The experiments were performed at a wellcharacterized sand and gravel aquifer, located in the Leine River valley near Göttingen, Germany. Access to the shallow subsurface was provided by direct-push technology. The high spatial resolution of hydraulic and seismic tomography was exploited to derive representative site-specific relationships between the hydraulic and geophysical parameters, based on the area where geophysical and hydraulic tests were performed. The transformation of the p-wave velocities into hydraulic properties was undertaken using a k-means cluster analysis. Results demonstrate that the combination of hydraulic and geophysical tomographic data is a promising approach to improve hydrogeophysical site characterization.

  2. Tomographic Imaging of Water Injection and Withdrawal in PEMFC Gas Diffusion Layers

    Energy Technology Data Exchange (ETDEWEB)

    McGill U; Gostick, J. T.; Gunterman, H. P.; Weber, A. Z.; Newman, J. S.; Kienitz, B. L.; MacDowell, A. A.

    2010-06-25

    X-ray computed tomography was used to visualize the water configurations inside gas diffusion layers for various applied capillary pressures, corresponding to both water invasion and withdrawal. A specialized sample holder was developed to allow capillary pressure control on the small-scale samples required. Tests were performed on GDL specimens with and without hydrophobic treatments.

  3. Atlas-based head modeling and spatial normalization for high-density diffuse optical tomography: in vivo validation against fMRI.

    Science.gov (United States)

    Ferradal, Silvina L; Eggebrecht, Adam T; Hassanpour, Mahlega; Snyder, Abraham Z; Culver, Joseph P

    2014-01-15

    Diffuse optical imaging (DOI) is increasingly becoming a valuable neuroimaging tool when fMRI is precluded. Recent developments in high-density diffuse optical tomography (HD-DOT) overcome previous limitations of sparse DOI systems, providing improved image quality and brain specificity. These improvements in instrumentation prompt the need for advancements in both i) realistic forward light modeling for accurate HD-DOT image reconstruction, and ii) spatial normalization for voxel-wise comparisons across subjects. Individualized forward light models derived from subject-specific anatomical images provide the optimal inverse solutions, but such modeling may not be feasible in all situations. In the absence of subject-specific anatomical images, atlas-based head models registered to the subject's head using cranial fiducials provide an alternative solution. In addition, a standard atlas is attractive because it defines a common coordinate space in which to compare results across subjects. The question therefore arises as to whether atlas-based forward light modeling ensures adequate HD-DOT image quality at the individual and group level. Herein, we demonstrate the feasibility of using atlas-based forward light modeling and spatial normalization methods. Both techniques are validated using subject-matched HD-DOT and fMRI data sets for visual evoked responses measured in five healthy adult subjects. HD-DOT reconstructions obtained with the registered atlas anatomy (i.e. atlas DOT) had an average localization error of 2.7mm relative to reconstructions obtained with the subject-specific anatomical images (i.e. subject-MRI DOT), and 6.6mm relative to fMRI data. At the group level, the localization error of atlas DOT reconstruction was 4.2mm relative to subject-MRI DOT reconstruction, and 6.1mm relative to fMRI. These results show that atlas-based image reconstruction provides a viable approach to individual head modeling for HD-DOT when anatomical imaging is not available

  4. Contribution to the study of proton elastic and inelastic scattering on {sup 12}C; Contribution a l'etude des diffusions elastiques et inelastiques des protons sur le carbone 12

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghi, A

    1966-07-01

    The results of absolute measurements of cross sections for the scattering of protons by {sup 12}C to the two first excited levels are given. The measurements were made from 4.6 to 11.4 MeV at 17 angles for (p,p) and at 15 angles for (p,p') (1. excited level) as well as 8 angles for (p,p'') (2. excited level). A gaseous target with differential pumping was used. The elastic scattering was analyzed using the R-matrix theory with the optical model. Then a new analysis of both (p,p) and (p,p') was achieved using the coupled-wave formalism. The information on the levels of the compound nucleus was completed and was confirmed. (author) [French] Cette these rapporte le resultat de mesures absolues des sections efficaces de diffusion p,p et pp' (conduisant aux deux premiers niveaux excites) de protons par '1'2C. Ces mesures ont ete faites de 4,6 a 11,4 MeV, a 17 angles pour (p,p), a 15 angles pour pp' (1er niveau excite) et a 8 angles pour pp'' (2eme niveau excite). Une chambre a cible gazeuse avec pompage differentiel a ete utilisee. La diffusion elastique a ete analysee au moyen de la theorie de la matrice R avec modele optique pour (p,p). Cette analyse a ete reprise en meme temps que celle de la diffusion inelastique par l'emploi d'equations couplees. Les resultats anterieurs sur les niveaux du noyau compose ont ete confirmes et completes. (auteur)

  5. Factors Associated with Diffusely Increased Splenic F-18 FDG Uptake in Patients with Cholangiocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Keunyoung; Kim, Seongjang; Kim, Injoo; Kim, Dong Uk; Kim, Heeyoung; Kim, Sojung; Ahn, Sang Hyun [Pusan National Univ. Hospital, Busan (Korea, Republic of)

    2014-06-15

    Although diffuse splenic {sup 18}F-fluorodeoxyglucose (F-18 FDG) uptake exceeding hepatic activity, is considered abnormal, its clinical significance is rarely discussed in the literature. The aim of this study was to determine the contributing factors causing diffusely increased splenic FDG uptake in patients with cholangiocarcinoma. From January 2010 to March 2013, 140 patients (84 men, 56 women) were enrolled in this study. All patients had been diagnosed with cholangiocarcinoma and underwent F-18 FDG positron emission tomography/computed tomography (PET/CT) for the pretreatment staging work up. Clinical records were reviewed retrospectively. Various hematological parameters, C-reactive protein (CRP) level, CEA, CA19-9, pancreatic enzymes and liver function tests were conducted within 2 days after the F-18 FDG PET/CT study. Diffuse splenic uptake was observed in 23 patients (16.4%). Of those, 19 patients (82.6%) underwent endoscopic retrograde cholangiopancreastography (ERCP) 7 days before F-18 FDG PET/CT. The CRP level (p <0.001) and white blood cell count (p =0.023) were significantly higher in the group of patients with diffuse splenic FDG uptake. The hemoglobin (p <0.001) and the hematocrit (p <0.001) were significantly lower in patients with diffuse splenic FDG uptake. Pancreatic enzymes, liver function test results, and tumor markers were not significantly different between the patients who did or did not have diffusely increased splenic FDG uptake. The significant factors for diffuse splenic F-18 FDG uptake exceeding hepatic F-18 FDG uptake on multivariate analysis included: performing ERCP before F-18 FDG PET-CT (odds ratio [OR], 77.510; 95% CI, 7.624-132.105), and the presence of leukocytosis (OR, 12.436; 95% CI, 2.438-63.445) or anemia (OR, 1.211; 95% CI, 1.051-1.871). In conclusion, our study demonstrated that concurrent inflammation could be associated with diffusely increased splenic FDG uptake. We suggest that performing ERCP before F-18 FDG PET

  6. Factors Associated with Diffusely Increased Splenic F-18 FDG Uptake in Patients with Cholangiocarcinoma

    International Nuclear Information System (INIS)

    Kim, Keunyoung; Kim, Seongjang; Kim, Injoo; Kim, Dong Uk; Kim, Heeyoung; Kim, Sojung; Ahn, Sang Hyun

    2014-01-01

    Although diffuse splenic 18 F-fluorodeoxyglucose (F-18 FDG) uptake exceeding hepatic activity, is considered abnormal, its clinical significance is rarely discussed in the literature. The aim of this study was to determine the contributing factors causing diffusely increased splenic FDG uptake in patients with cholangiocarcinoma. From January 2010 to March 2013, 140 patients (84 men, 56 women) were enrolled in this study. All patients had been diagnosed with cholangiocarcinoma and underwent F-18 FDG positron emission tomography/computed tomography (PET/CT) for the pretreatment staging work up. Clinical records were reviewed retrospectively. Various hematological parameters, C-reactive protein (CRP) level, CEA, CA19-9, pancreatic enzymes and liver function tests were conducted within 2 days after the F-18 FDG PET/CT study. Diffuse splenic uptake was observed in 23 patients (16.4%). Of those, 19 patients (82.6%) underwent endoscopic retrograde cholangiopancreastography (ERCP) 7 days before F-18 FDG PET/CT. The CRP level (p <0.001) and white blood cell count (p =0.023) were significantly higher in the group of patients with diffuse splenic FDG uptake. The hemoglobin (p <0.001) and the hematocrit (p <0.001) were significantly lower in patients with diffuse splenic FDG uptake. Pancreatic enzymes, liver function test results, and tumor markers were not significantly different between the patients who did or did not have diffusely increased splenic FDG uptake. The significant factors for diffuse splenic F-18 FDG uptake exceeding hepatic F-18 FDG uptake on multivariate analysis included: performing ERCP before F-18 FDG PET-CT (odds ratio [OR], 77.510; 95% CI, 7.624-132.105), and the presence of leukocytosis (OR, 12.436; 95% CI, 2.438-63.445) or anemia (OR, 1.211; 95% CI, 1.051-1.871). In conclusion, our study demonstrated that concurrent inflammation could be associated with diffusely increased splenic FDG uptake. We suggest that performing ERCP before F-18 FDG PET

  7. Space-Varying Iterative Restoration of Diffuse Optical Tomograms Reconstructed by the Photon Average Trajectories Method

    Directory of Open Access Journals (Sweden)

    Kravtsenyuk Olga V

    2007-01-01

    Full Text Available The possibility of improving the spatial resolution of diffuse optical tomograms reconstructed by the photon average trajectories (PAT method is substantiated. The PAT method recently presented by us is based on a concept of an average statistical trajectory for transfer of light energy, the photon average trajectory (PAT. The inverse problem of diffuse optical tomography is reduced to a solution of an integral equation with integration along a conditional PAT. As a result, the conventional algorithms of projection computed tomography can be used for fast reconstruction of diffuse optical images. The shortcoming of the PAT method is that it reconstructs the images blurred due to averaging over spatial distributions of photons which form the signal measured by the receiver. To improve the resolution, we apply a spatially variant blur model based on an interpolation of the spatially invariant point spread functions simulated for the different small subregions of the image domain. Two iterative algorithms for solving a system of linear algebraic equations, the conjugate gradient algorithm for least squares problem and the modified residual norm steepest descent algorithm, are used for deblurring. It is shown that a gain in spatial resolution can be obtained.

  8. Space-Varying Iterative Restoration of Diffuse Optical Tomograms Reconstructed by the Photon Average Trajectories Method

    Directory of Open Access Journals (Sweden)

    Vladimir V. Lyubimov

    2007-01-01

    Full Text Available The possibility of improving the spatial resolution of diffuse optical tomograms reconstructed by the photon average trajectories (PAT method is substantiated. The PAT method recently presented by us is based on a concept of an average statistical trajectory for transfer of light energy, the photon average trajectory (PAT. The inverse problem of diffuse optical tomography is reduced to a solution of an integral equation with integration along a conditional PAT. As a result, the conventional algorithms of projection computed tomography can be used for fast reconstruction of diffuse optical images. The shortcoming of the PAT method is that it reconstructs the images blurred due to averaging over spatial distributions of photons which form the signal measured by the receiver. To improve the resolution, we apply a spatially variant blur model based on an interpolation of the spatially invariant point spread functions simulated for the different small subregions of the image domain. Two iterative algorithms for solving a system of linear algebraic equations, the conjugate gradient algorithm for least squares problem and the modified residual norm steepest descent algorithm, are used for deblurring. It is shown that a 27% gain in spatial resolution can be obtained.

  9. Clinico-pathological consideration of diffuse brain injury. Does it possible to diagnosis the diffuse axonal injury by using computed imagings?

    International Nuclear Information System (INIS)

    Fukuda, Tadaharu; Takeda, Hiroki; Matsumura, Hiroyuki; Izawa, Hitoshi; Nakanishi, Fuminori; Onitsuka, Toshirou; Nakajima, Satoshi; Hasue, Masamichi; Ito, Hiroshi

    1998-01-01

    We studied 146 cases with clinical symptoms equivalent to diffuse axonal injury (DAI) according to Gennarelli et al., and initial CT findings equivalent to diffuse injury I, II and III according to Marshall et al. The relationships between computed imagings (CI) assessments, various monitorings, higher order cerebral functions during follow-up, and long-term prognosis were investigated, and the feasibility of assessing the nature of diffuse brain damage by CI was examined. Each of the three CI conducted; computed tomography (CT), magnetic resonance imaging (MRI) T2-weighted image, and 123I-IMP single photon emission computed tomography (SPECT), by itself failed to achieve accurate assessment of outcome. No correlation was observed between acute phase CT finding and the highest WAIS or WISC score from 3 months to within 2 years after injury. Fifty percent of survivors had normal cerebro-ventricular index (CVI) calculated from chronic phase CT images. The correlation between chronic phase CVI and acute phase CT or MRI grade was weak. Even in cases with increased CVI and severe cerebral atrophy, improvement in higher order cerebral function was observed in young patients. In acute phase DAI, cerebral circulatory disorders such as cerebral blood flow and cerebral blood volume changes and electro-physiological disorders such as abnormal somato-sensory evoked potentials were present, and these disorders resolved with time in survivors. Recovery from these disorders tended to correlate with improvement of consciousness level. These findings indicate that the clinical symptoms of DAI are composed of reversible functional impairments. The current CI techniques cannot differentiate between irreversible neural damages and transient functional impairments, and also cannot predict the recovery process due to sprouting and other mechanisms. For these reasons, discrepancies exist between acute phase CI findings and outcomes, especially functional prognosis. (author)

  10. High-resolution computed tomography and histopathological findings in hypersensitivity pneumonitis: a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Pedro Paulo Teixeira e Silva; Moreira, Marise Amaral Reboucas; Silva, Daniela Graner Schuwartz Tannus; Moreira, Maria Auxiliadora do Carmo [Universidade Federal de Goias (UFG), Goiania, GO (Brazil); Gama, Roberta Rodrigues Monteiro da [Hospital do Cancer de Barretos, Barretos, SP (Brazil); Sugita, Denis Masashi, E-mail: pedroptstorres@yahoo.com.br [Anapolis Unievangelica, Anapolis, GO (Brazil)

    2016-03-15

    Hypersensitivity pneumonitis is a diffuse interstitial and granulomatous lung disease caused by the inhalation of any one of a number of antigens. The objective of this study was to illustrate the spectrum of abnormalities in high-resolution computed tomography and histopathological findings related to hypersensitivity pneumonitis. We retrospectively evaluated patients who had been diagnosed with hypersensitivity pneumonitis (on the basis of clinical-radiological or clinical-radiological-pathological correlations) and had undergone lung biopsy. Hypersensitivity pneumonitis is clinically divided into acute, subacute, and chronic forms; high-resolution computed tomography findings correlate with the time of exposure; and the two occasionally overlap. In the subacute form, centrilobular micronodules, ground glass opacities, and air trapping are characteristic high-resolution computed tomography findings, whereas histopathology shows lymphocytic inflammatory infiltrates, bronchiolitis, variable degrees of organizing pneumonia, and giant cells. In the chronic form, high-resolution computed tomography shows traction bronchiectasis, honeycombing, and lung fibrosis, the last also being seen in the biopsy sample. A definitive diagnosis of hypersensitivity pneumonitis can be made only through a multidisciplinary approach, by correlating clinical findings, exposure history, high-resolution computed tomography findings, and lung biopsy findings. (author)

  11. Digital optical tomography system for dynamic breast imaging

    Science.gov (United States)

    Flexman, Molly L.; Khalil, Michael A.; Al Abdi, Rabah; Kim, Hyun K.; Fong, Christopher J.; Desperito, Elise; Hershman, Dawn L.; Barbour, Randall L.; Hielscher, Andreas H.

    2011-07-01

    Diffuse optical tomography has shown promising results as a tool for breast cancer screening and monitoring response to chemotherapy. Dynamic imaging of the transient response of the breast to an external stimulus, such as pressure or a respiratory maneuver, can provide additional information that can be used to detect tumors. We present a new digital continuous-wave optical tomography system designed to simultaneously image both breasts at fast frame rates and with a large number of sources and detectors. The system uses a master-slave digital signal processor-based detection architecture to achieve a dynamic range of 160 dB and a frame rate of 1.7 Hz with 32 sources, 64 detectors, and 4 wavelengths per breast. Included is a preliminary study of one healthy patient and two breast cancer patients showing the ability to identify an invasive carcinoma based on the hemodynamic response to a breath hold.

  12. Cationic Contrast Agent Diffusion Differs Between Cartilage and Meniscus.

    Science.gov (United States)

    Honkanen, Juuso T J; Turunen, Mikael J; Freedman, Jonathan D; Saarakkala, Simo; Grinstaff, Mark W; Ylärinne, Janne H; Jurvelin, Jukka S; Töyräs, Juha

    2016-10-01

    Contrast enhanced computed tomography (CECT) is a non-destructive imaging technique used for the assessment of composition and structure of articular cartilage and meniscus. Due to structural and compositional differences between these tissues, diffusion and distribution of contrast agents may differ in cartilage and meniscus. The aim of this study is to determine the diffusion kinematics of a novel iodine based cationic contrast agent (CA(2+)) in cartilage and meniscus. Cylindrical cartilage and meniscus samples (d = 6 mm, h ≈ 2 mm) were harvested from healthy bovine knee joints (n = 10), immersed in isotonic cationic contrast agent (20 mgI/mL), and imaged using a micro-CT scanner at 26 time points up to 48 h. Subsequently, normalized X-ray attenuation and contrast agent diffusion flux, as well as water, collagen and proteoglycan (PG) contents in the tissues were determined. The contrast agent distributions within cartilage and meniscus were different. In addition, the normalized attenuation and diffusion flux were higher (p < 0.05) in cartilage. Based on these results, diffusion kinematics vary between cartilage and meniscus. These tissue specific variations can affect the interpretation of CECT images and should be considered when cartilage and meniscus are assessed simultaneously.

  13. Diffusible iodine-based contrast-enhanced computed tomography (diceCT): an emerging tool for rapid, high-resolution, 3-D imaging of metazoan soft tissues.

    Science.gov (United States)

    Gignac, Paul M; Kley, Nathan J; Clarke, Julia A; Colbert, Matthew W; Morhardt, Ashley C; Cerio, Donald; Cost, Ian N; Cox, Philip G; Daza, Juan D; Early, Catherine M; Echols, M Scott; Henkelman, R Mark; Herdina, A Nele; Holliday, Casey M; Li, Zhiheng; Mahlow, Kristin; Merchant, Samer; Müller, Johannes; Orsbon, Courtney P; Paluh, Daniel J; Thies, Monte L; Tsai, Henry P; Witmer, Lawrence M

    2016-06-01

    Morphologists have historically had to rely on destructive procedures to visualize the three-dimensional (3-D) anatomy of animals. More recently, however, non-destructive techniques have come to the forefront. These include X-ray computed tomography (CT), which has been used most commonly to examine the mineralized, hard-tissue anatomy of living and fossil metazoans. One relatively new and potentially transformative aspect of current CT-based research is the use of chemical agents to render visible, and differentiate between, soft-tissue structures in X-ray images. Specifically, iodine has emerged as one of the most widely used of these contrast agents among animal morphologists due to its ease of handling, cost effectiveness, and differential affinities for major types of soft tissues. The rapid adoption of iodine-based contrast agents has resulted in a proliferation of distinct specimen preparations and scanning parameter choices, as well as an increasing variety of imaging hardware and software preferences. Here we provide a critical review of the recent contributions to iodine-based, contrast-enhanced CT research to enable researchers just beginning to employ contrast enhancement to make sense of this complex new landscape of methodologies. We provide a detailed summary of recent case studies, assess factors that govern success at each step of the specimen storage, preparation, and imaging processes, and make recommendations for standardizing both techniques and reporting practices. Finally, we discuss potential cutting-edge applications of diffusible iodine-based contrast-enhanced computed tomography (diceCT) and the issues that must still be overcome to facilitate the broader adoption of diceCT going forward. © 2016 The Authors. Journal of Anatomy published by John Wiley & Sons Ltd on behalf of Anatomical Society.

  14. Derivation of a Monte Carlo method for modeling heterodyne detection in optical coherence tomography systems

    DEFF Research Database (Denmark)

    Tycho, Andreas; Jørgensen, Thomas Martini; Andersen, Peter E.

    2002-01-01

    A Monte Carlo (MC) method for modeling optical coherence tomography (OCT) measurements of a diffusely reflecting discontinuity emb edded in a scattering medium is presented. For the first time to the authors' knowledge it is shown analytically that the applicability of an MC approach to this opti...

  15. Diffusion and perfusion MRI for the localisation of epileptogenic foci in drug-resistant epilepsy

    International Nuclear Information System (INIS)

    Heiniger, P.; El-Koussy, M.; Kiefer, C.; Oswald, H.; Schroth, G.; Schindler, K.; Donati, F.; Loevblad, K.O.; Wissmeyer, M.; Mariani, L.; Weder, B.

    2002-01-01

    Drug-resistant epilepsy is an important clinical challenge, both diagnostically and therapeutically. More and more surgical options are being considered, but precise presurgical assessment is necessary. We prospectively studied eight patients with drug-resistant epilepsy, who underwent clinical examination, single photon emission computed tomography (SPECT) and interictal MRI, including diffusion- and perfusion-weighted echoplanar sequences. Lesions suspected on SPECT of being epileptogenic showed mild hypoperfusion, while the diffusion-weighted MRI (DWI) revealed increased apparent diffusion coefficients relative to the other side. However, these abnormalities were not visible on the corresponding maps. We showed that DWI and perfusion-weighted MRI could be used confirm the characteristics and site of an epileptogenic area in patients with drug-resistant epilepsy. (orig.)

  16. Emission tomography: quantitative aspects in metabolic and physio-pathologic studies

    International Nuclear Information System (INIS)

    Yerouchalmi-Soussaline, F.

    1984-01-01

    This thesis presents instrumental and data processing studies developed in emission tomography in man, using gamma and positron emitting tracers. High contrast visualisation of volume distribution of tracers in the organs, kinetic studies and measurements of radioactive concentration or of other clinical parameters necessitate a detailed analysis of all physical factors limiting the accuracy of the measure; therefore, development of adapted imaging devices and data processing techniques, together with models describing correctly the phenomena under study are to be carried out. Thus, in single photon (gamma) emission tomography an image reconstruction strategy is elaborated, based on an analytical model for the ill-posed problem including the attenuation effect. In positron emission tomography, the time-of-flight information combined with the reconstruction technique is used in the design of a first prototype imaging device which performance is presented and evaluated in a clinical environment. Moreover, a priori or a posteriori techniques correcting for Compton diffusion events, limited statistics and limited resolution, are proposed and discussed for the improvement of regional measurement accuracy, in metabolic and physio-pathologic studies. (author) [fr

  17. The effects of gas diffusion layers structure on water transportation using X-ray computed tomography based Lattice Boltzmann method

    Science.gov (United States)

    Jinuntuya, Fontip; Whiteley, Michael; Chen, Rui; Fly, Ashley

    2018-02-01

    The Gas Diffusion Layer (GDL) of a Polymer Electrolyte Membrane Fuel Cell (PEMFC) plays a crucial role in overall cell performance. It is responsible for the dissemination of reactant gasses from the gas supply channels to the reactant sites at the Catalyst Layer (CL), and the adequate removal of product water from reactant sites back to the gas channels. Existing research into water transport in GDLs has been simplified to 2D estimations of GDL structures or use virtual stochastic models. This work uses X-ray computed tomography (XCT) to reconstruct three types of GDL in a model. These models are then analysed via Lattice Boltzmann methods to understand the water transport behaviours under differing contact angles and pressure differences. In this study, the three GDL samples were tested over the contact angles of 60°, 80°, 90°, 100°, 120° and 140° under applied pressure differences of 5 kPa, 10 kPa and 15 kPa. By varying the contact angle and pressure difference, it was found that the transition between stable displacement and capillary fingering is not a gradual process. Hydrophilic contact angles in the region of 60°<θ < 90° showed stable displacement properties, whereas contact angles in the region of 100°<θ < 140° displayed capillary fingering characteristics.

  18. Diffuse Anterior Retinoblastoma with Sarcoidosis-Like Nodule

    Directory of Open Access Journals (Sweden)

    Koji Kitazawa

    2015-12-01

    Full Text Available Background: Retinoblastomas account for 4% of malignancies in children, 1-2% of which are diffuse infiltrating retinoblastomas. Diffuse anterior retinoblastoma is rare and does not involve the retina. Here, we report on a diffuse anterior retinoblastoma with large sarcoidosis-like nodules on the iris that were responsive to anti-inflammatory therapy. Case: We present a 6-year-old girl who had anterior uveitis with white nodules on the iris and posterior surface of the cornea in her right eye. The nodules initially responded well to anti-inflammatory treatment. However, anterior segment optical coherence tomography (AS-OCT showed that the nodules gradually grew, shrinking the iris. We then collected the aqueous humor for diagnosis. A biopsy revealed clusters of small cells with a high nuclear-to-cytoplasm ratio with partial rosette formation. Therefore, we diagnosed diffuse anterior retinoblastoma without retinal involvement and performed enucleation of the right eye. The histopathology demonstrated undifferentiated cells similar to those seen on the biopsy, and tumor cells invaded the iris stroma, posterior surface of the cornea, ciliary body, and sclera. After the enucleation, she underwent chemotherapy and remains alive. Conclusion: A differential diagnosis of retinoblastoma should be considered when white nodules refractory to anti-inflammatory therapy occur in the eye, even in the absence of obvious retinal masses. AS-OCT findings are useful in assessing retinoblastoma.

  19. Calculation of calcium diffusion coefficient of cement hardenings using minute pore data

    International Nuclear Information System (INIS)

    Hitomi, Takashi; Takeda, Nobufumi; Iriya, Keishiro

    2009-01-01

    This report describes the calculations of the diffusion coefficient of the Ca ion of cement hardenings using minute pore data. The observed hardenings were ordinary Portland cement (OPC), low-heat Portland cement with fly ash (LPC+FA) and highly fly ash containing silica fume cement (HFSC). The samples were cured in the standard and artificially leached by accelerated test. Minute pore datas of the cement hardenings were acquired with image processing of internal structural information obtained from high resolution X-ray computed tomography observations. Upon analysis, several voxels are combined into one bigger voxel, the diffusion coefficient of the voxels were determined in proportion to the number of voxels which were included in. The results reveal that the change in the calcium diffusion coefficient of OPC due to leaching was large, but the LPC+FA and HFSC cements exhibited even greater changes than OPC. It is suggested that the diffusion coefficients are proportional to the Ca/Si ratio of the samples. (author)

  20. Primary testicular diffuse large B-cell lymphoma: A case report

    Directory of Open Access Journals (Sweden)

    Muhammad Sadiq

    2017-12-01

    Full Text Available Primary testicular diffuse large-B cell lymphoma (DLBCL is an uncommon and aggressive disease with predominant manifestation in the older age. Herein, we report a case of 47-year-old male patient who presented with three months history of left testis swelling. The patient underwent unilateral (left radical orchiectomy. Histopathological examination revealed extensive involvement and replacement of testicular parenchyma by a tumor composed of large discohesive sheets of cells with pleomorphic, hyperchromatic nuclei and prominent nucleoli. Immunohistochemical (IHC staining showed reactivity for LCA & Pan B (CD20 and negativity for OCT 3/4, SALL4 and Inhibin. Moreover, Pan T (CD3 highlighted reactive T-cells. These features rendered the diagnosis of DLBCL of testis. The hybrid 2-[fluorine-18] fluoro-2-deoxy-d-glucose (FDG positron emission tomography/computed tomography (PET/CT demonstrated two para-aortic FDG avid lymph nodes on the left side at the level of L2 vertebra. Presently, the patient has been planned for doxorubicin-based chemotherapy (i.e., cyclophosphamide, doxorubicin, vincristine and prednisone; CHOP along with intrathecal Methroxate (MTX, which would presumably improve the prognosis. Our study would expand the pool of this uncommon tumor towards its better understanding. Keywords: Primary testicular lymphoma, Diffuse large-B cell lymphoma, Orchiectomy, Doxorubicin-based chemotherapy

  1. Fluorodeoxyglucose Positron Emission Tomography–Computed Tomography in Disseminated Cryptococcosis

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography–computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm. PMID:29142368

  2. Local inversions in ultrasound-modulated optical tomography

    International Nuclear Information System (INIS)

    Bal, Guillaume; Moskow, Shari

    2014-01-01

    Ultrasound-modulated optical tomography is a hybrid imaging modality that aims to combine the high contrast of optical waves with the high resolution of ultrasound. We follow the model of the influence of ultrasound modulation on the light intensity measurements developed in Bal and Schotland (2010 Phys. Rev. Lett. 104 043902). We present sufficient conditions ensuring that the absorption and diffusion coefficients modeling light propagation can locally be uniquely and stably reconstructed from the corresponding available information. We present an iterative procedure to solve such a problem based on the analysis of linear elliptic systems of redundant partial differential equations. (paper)

  3. Optical coherence tomography for glucose monitoring in blood

    Science.gov (United States)

    Ullah, Hafeez; Hussain, Fayyaz; Ikram, Masroor

    2015-08-01

    In this review, we have discussed the potential application of the emerging imaging modality, i.e., optical coherence tomography (OCT) for glucose monitoring in biological tissues. OCT provides monitoring of glucose diffusion in different fibrous tissues like in sclera by determining the permeability rate with acceptable accuracy both in type 1 and in type 2 diabetes. The maximum precision of glucose measurement in Intralipid suspensions, for example, with the OCT technique yields the accuracy up to 4.4 mM for 10 % Intralipid and 2.2 mM for 3 % Intralipid.

  4. Optical coherence tomography patterns as predictors of visual outcome in dengue-related maculopathy.

    Science.gov (United States)

    Teoh, Stephen C; Chee, Caroline K; Laude, Augustinus; Goh, Kong Y; Barkham, Timothy; Ang, Brenda S

    2010-03-01

    The purpose of this study was to characterize the presentations, long-term outcomes, and visual prognostic factors in dengue-related maculopathy of 41 patients with dengue fever and impaired vision from dengue-related maculopathy in a retrospective noninterventional and observational series. The medical records of patients with dengue-related maculopathy diagnosed over 18 months between July 2004 and December 2005 at The Eye Institute, Tan Tock Seng Hospital and Communicable Disease Center, Singapore, were reviewed and followed up for 24 months. Visual acuity and symptoms (presence of scotoma on automated visual fields and Amsler grid) were correlated with optical coherence tomography evaluation. Mean age was 28.7 years and there were more men (53.7%). The most common visual complaints were blurring of vision (51.2%) and central scotoma (34.1%). Most patients recovered best-corrected visual acuity >20/40. Optical coherence tomography showed 3 patterns of maculopathy: 1) diffuse retinal thickening; 2) cystoid macular edema; and 3) foveolitis. The visual outcome was independent of the extent of edema, but scotomata persisted longest in patients with foveolitis and shortest with those with diffuse retinal thickening. Dengue-associated ocular inflammation is an emerging ophthalmic condition and often involves the posterior segment. Prognosis is variable. Patients usually regain good vision but may retain persistent scotomata even at 2 years despite clinical resolution of the disease. Optical coherence tomography patterns in dengue maculopathy are useful for characterization, monitoring, and prognostication of the visual defect.

  5. Patch-based anisotropic diffusion scheme for fluorescence diffuse optical tomography—part 1: technical principles

    International Nuclear Information System (INIS)

    Correia, Teresa; Arridge, Simon

    2016-01-01

    Fluorescence diffuse optical tomography (fDOT) provides 3D images of fluorescence distributions in biological tissue, which represent molecular and cellular processes. The image reconstruction problem is highly ill-posed and requires regularisation techniques to stabilise and find meaningful solutions. Quadratic regularisation tends to either oversmooth or generate very noisy reconstructions, depending on the regularisation strength. Edge preserving methods, such as anisotropic diffusion regularisation (AD), can preserve important features in the fluorescence image and smooth out noise. However, AD has limited ability to distinguish an edge from noise. In this two-part paper, we propose a patch-based anisotropic diffusion regularisation (PAD), where regularisation strength is determined by a weighted average according to the similarity between patches around voxels within a search window, instead of a simple local neighbourhood strategy. However, this method has higher computational complexity and, hence, we wavelet compress the patches (PAD-WT) to speed it up, while simultaneously taking advantage of the denoising properties of wavelet thresholding. The proposed method combines the nonlocal means (NLM), AD and wavelet shrinkage methods, which are image processing methods. Therefore, in this first paper, we used a denoising test problem to analyse the performance of the new method. Our results show that the proposed PAD-WT method provides better results than the AD or NLM methods alone. The efficacy of the method for fDOT image reconstruction problem is evaluated in part 2. (paper)

  6. Current and future diagnostic tools for traumatic brain injury: CT, conventional MRI, and diffusion tensor imaging.

    Science.gov (United States)

    Brody, David L; Mac Donald, Christine L; Shimony, Joshua S

    2015-01-01

    Brain imaging plays a key role in the assessment of traumatic brain injury. In this review, we present our perspectives on the use of computed tomography (CT), conventional magnetic resonance imaging (MRI), and newer advanced modalities such as diffusion tensor imaging. Specifically, we address assessment for immediately life-threatening intracranial lesions (noncontrast head CT), assessment of progression of intracranial lesions (noncontrast head CT), documenting intracranial abnormalities for medicolegal reasons (conventional MRI with blood-sensitive sequences), presurgical planning for post-traumatic epilepsy (high spatial resolution conventional MRI), early prognostic decision making (conventional MRI with diffusion-weighted imaging), prognostic assessment for rehabilitative planning (conventional MRI and possibly diffusion tensor imaging in the future), stratification of subjects and pharmacodynamic tracking of targeted therapies in clinical trials (specific MRI sequences or positron emission tomography (PET) ligands, e.g., diffusion tensor imaging for traumatic axonal injury). We would like to emphasize that all of these methods, especially the newer research approaches, require careful radiologic-pathologic validation for optimal interpretation. We have taken this approach in a mouse model of pericontusional traumatic axonal injury. We found that the extent of reduction in the diffusion tensor imaging parameter relative anisotropy directly correlated with the number of amyloid precursor protein (APP)-stained axonal varicosities (r(2)=0.81, p<0.0001, n=20 injured mice). Interestingly, however, the least severe contusional injuries did not result in APP-stained axonal varicosities, but did cause reduction in relative anisotropy. Clearly, both the imaging assessments and the pathologic assessments will require iterative refinement. © 2015 Elsevier B.V. All rights reserved.

  7. Atomic diffusion induced degradation in bimetallic layer coated cemented tungsten carbide

    International Nuclear Information System (INIS)

    Peng, Zirong; Rohwerder, Michael; Choi, Pyuck-Pa; Gault, Baptiste; Meiners, Thorsten; Friedrichs, Marcel; Kreilkamp, Holger; Klocke, Fritz; Raabe, Dierk

    2017-01-01

    Highlights: • We study the temporal degradation of PtIr/Cr/WC and PtIr/Ni/WC systems. • Short cut diffusion, segregation, oxidation and interdiffusion reactions occurred. • Outward diffusion of Cr (Ni) via PtIr grain boundaries triggered the degradation. • The microstructure of the PtIr layer controlled the systems stability. • We propose an atomic diffusion induced degradation mechanism. - Abstract: We investigated the temporal degradation of glass moulding dies, made of cemented tungsten carbide coated with PtIr on an adhesive Cr or Ni interlayer, by electron microscopy and atom probe tomography. During the exposure treatments at 630 °C under an oxygen partial pressure of 1.12 × 10"−"2"3 bar, Cr (Ni) was found to diffuse outwards via grain boundaries in the PtIr, altering the surface morphology. Upon dissolution of the interlayer, the WC substrate also started degrading. Extensive interdiffusion processes involving PtIr, Cr (Ni) and WC took place, leading to the formation of intermetallic phases and voids, deteriorating the adhesion of the coating.

  8. Various manifestations of hypertrophic cardiomyopathy on ultrafast computed tomography

    International Nuclear Information System (INIS)

    Sekiya, Tohru; Karikomi, Masahito; Ohshiro, Masaya; Iwakami, Masayoshi; Takamoto, Toshihiko; Sakamoto, Tsuguya

    1992-01-01

    Ultrafast computed tomography was performed in 30 patients with hypertrophic cardiomyopathy and images were assessed on variability of left ventricular hypertrophy, the pattern of left ventricular contraction, right ventricular hypertrophy, dilatation of the left atrium, and thickening of the mitral valve. Fifteen (50.0%) of 30 patients had asymmetric septal hypertrophy, six (20.0%) had diffuse hypertrophy, and nine (30.0%) had apical hypertrophy. In eleven patients with asymmetric septal hypertrophy and two with apical hypertrophy, non-hypertrophied segments in end-diastole showed vigorous contraction. Sixteen patients showed homogeneous left ventricular contraction and one showed partial apical contraction. Right ventricular hypertrophy was noted in 12 patients (40.0%), dilatation of the left atrium in 13 patients (43.3%), and mitral valve thickening in three (10.0%). Ultrafast computed tomography was useful in the evaluation of apical hypertrophy and right ventricular hypertrophy, which could be difficult to obtain by echocardiography. (author)

  9. The clinical impact of high resolution computed tomography in patients with respiratory disease

    International Nuclear Information System (INIS)

    Screaton, Nicholas J.; Tasker, Angela D.; Flower, Christopher D.R.; Miller, Fiona N.A.C.; Patel, Bipen D.; Groves, Ashley; Lomas, David A.

    2011-01-01

    High resolution computed tomography is widely used to investigate patients with suspected diffuse lung disease. Numerous studies have assessed the diagnostic performance of this investigation, but the diagnostic and therapeutic impacts have received little attention. The diagnostic and therapeutic impacts of high resolution computed tomography in routine clinical practice were evaluated prospectively. All 507 referrals for high-resolution computed tomography over 12 months in two centres were included. Requesting clinicians completed questionnaires before and after the investigation detailing clinical indications, working diagnoses, confidence level in each diagnosis, planned investigations and treatments. Three hundred and fifty-four studies on 347 patients had complete data and were available for analysis. Following high-resolution computed tomography, a new leading diagnosis (the diagnosis with the highest confidence level) emerged in 204 (58%) studies; in 166 (47%) studies the new leading diagnosis was not in the original differential diagnosis. Mean confidence in the leading diagnosis increased from 6.7 to 8.5 out of 10 (p < 0.001). The invasiveness of planned investigations increased in 23 (7%) studies and decreased in 124 (35%) studies. The treatment plan was modified after 319 (90%) studies. Thoracic high-resolution computed tomography alters leading diagnosis, increases diagnostic confidence, and frequently changes investigation and management plans. (orig.)

  10. De l'influence de la communication sur la diffusion artistique

    OpenAIRE

    Caune, Jean

    2013-01-01

    Selon J.Caune, la communication culturelle oriente, avant même que la transaction esthétique n'ait eu lieu, le rapport sensible qu'aura le spectateur à l'objet esthétique. Il étudie dans cette optique trois âges de la vie culturelle : la période vilarienne du théâtre comme communication sociale, la période Malraux où l'on a privilégié la « rencontre » entre l'individu et l'oeuvre d'art, la période de l'après 68, où s'est développée l'animation (socio)culturelle comme médiation.Il s'interroge ...

  11. Influence of excitation light rejection on forward model mismatch in optical tomography

    International Nuclear Information System (INIS)

    Hwang, K; Pan, T; Joshi, A; Rasmussen, J C; Bangerth, W; Sevick-Muraca, E M

    2006-01-01

    Fluorescence enhanced tomography for molecular imaging requires low background for detection and accurate image reconstruction. In this contribution, we show that excitation light leakage is responsible for elevated background and can be minimized with the use of gradient index (GRIN) lenses when using fibre optics to collect propagated fluorescence light from tissue or other biological media. We show that the model mismatch between frequency-domain photon migration (FDPM) measurements and the diffusion approximation prediction is decreased when GRIN lenses are placed prior to the interference filters to provide efficient excitation light rejection. Furthermore, model mismatch is correlated to the degree of excitation light leakage. This work demonstrates the importance of proper light filtering when designing fluorescence optical imaging and tomography

  12. Modeling of the blood flow in the lower extremities for dynamic diffuse optical tomography of peripheral artery disease

    Science.gov (United States)

    Marone, A.; Hoi, J. W.; Khalil, M. A.; Kim, H. K.; Shrikhande, G.; Dayal, R.; Hielscher, A. H.

    2015-07-01

    Peripheral Arterial Disease (PAD) is caused by a reduction of the internal diameters of the arteries in the upper or lower extremities mainly due to atherosclerosis. If not treated, its worsening may led to a complete occlusion, causing the death of the cells lacking proper blood supply, followed by gangrene that may require chirurgical amputation. We have recently performed a clinical study in which good sensitivities and specificities were achieved with dynamic diffuse optical tomography. To gain a better understanding of the physiological foundations of many of the observed effects, we started to develop a mathematical model for PAD. The model presented in this work is based on a multi-compartment Windkessel model, where the vasculature in the leg and foot is represented by resistors and capacitors, the blood pressure with a voltage drop, and the blood flow with a current. Unlike existing models, the dynamics induced by a thigh-pressure-cuff inflation and deflation during the measurements are taken into consideration. This is achieved by dynamically varying the resistances of the large veins and arteries. By including the effects of the thigh-pressure cuff, we were able to explain many of the effects observed during our dynamic DOT measurements, including the hemodynamics of oxy- and deoxy-hemoglobin concentration changes. The model was implemented in MATLAB and the simulations were normalized and compared with the blood perfusion obtained from healthy, PAD and diabetic patients. Our preliminary results show that in unhealthy patients the total system resistance is sensibly higher than in healthy patients.

  13. Ultrasonography and computed tomography in diffuse liver disease with cholestasis

    International Nuclear Information System (INIS)

    Partanen, K.; Pikkarainen, P.; Pasanen, P.; Alhava, E.; Soimakallio, S.; Kuopio Univ. Central Hospital; Kuopio Univ. Central Hospital

    1990-01-01

    Ultrasonography (US) and computed tomography (CT) were performed on respectively 67 and 42 (altogether 72) patients, for the assessment of intrahepatic cholestasis. The diagnostic ability to differentiate between malignant (17 patients) and benign (55 patients) liver disease was analyzed. Coarse echogenicity of the liver led to inconclusive results in differentiating between cirrhosis (2 out of 29 patients) and malignant infiltration (4 out of 15 patients) by US. Other benign liver diseases in 23 patients, including acute hepatitis, chronic active hepatitis, fatty liver, and liver congestion, were correctly interpreted as benign. CT correctly disclosed malignant liver disease in all cases. A false positive diagnosis of malignancy was encountered in 4 (out of 17) patients with decompensated hepatic cirrhosis because of non-homogeneous expansive areas on CT in 3 cases. The true cause was in 2 patients non-uniform fatty infiltration, and in one patient with acute hepatitis A, small hypodense lesions. Among cholestatic patients, decompensated cirrhosis and malignant liver infiltration could not always be differentiated on US or CT. (orig.)

  14. Diffuse metastatic infiltration of a carcinoma into skeletal muscle

    International Nuclear Information System (INIS)

    Hundt, W.; Braunschweig, R.; Reiser, M.

    1999-01-01

    Skeletal muscle is one of the most unusual sites of metastasis from any malignancy. We report a patient with rapidly progressive contractures due to metastatic infiltration of a carcinoma of unknown origin into the skeletal muscle. This 61-year-old man presented with a 1-month history of rapidly evolving, painful restriction of mobility of his right arm and his legs. Computed tomography showed diffuse metastatic nodules in all muscles, particularly in the hip abductors. Muscle biopsy revealed extensive infiltration of the muscle with carcinoma cells. (orig.)

  15. Algorithmic fundamentals of computerized tomography and of transverse analogue tomography

    International Nuclear Information System (INIS)

    Heckmann, K.

    1981-01-01

    Computerized tomography and transverse analogue tomography are two different approaches to the same goal, namely, transverse tomography. The algorithm is discussed and compared. Transverse tomography appears capable of further development, judging by this comparison. (orig.) [de

  16. Investigation of the diffusion behavior of sodium in Cu(In,Ga)Se{sub 2} layers

    Energy Technology Data Exchange (ETDEWEB)

    Laemmle, Anke, E-mail: anke.laemmle@zsw-bw.de; Wuerz, Roland; Powalla, Michael [Zentrum für Sonnenenergie- und Wasserstoff-Forschung Baden Württemberg, Industriestraße 6, 70565 Stuttgart (Germany); Schwarz, Torsten; Cojocaru-Mirédin, Oana; Choi, Pyuck-Pa [Max-Planck-Institut für Eisenforschung, Max-Planck-Str. 1, 40237 Düsseldorf (Germany)

    2014-04-21

    Sodium diffusion in Cu(In,Ga)Se{sub 2} (CIGS) layers was investigated over a temperature range from 157 °C to 400 °C. The diffusion profiles were measured by secondary ion mass spectrometry. Sodium ions diffused from a sodium fluoride (NaF) layer on the CIGS surface into the CIGS layer. From Na diffusion profiles, the diffusion along grain boundaries could be distinguished from the diffusion into the grain interior. Atom-probe tomography measurements reveal that even at a low temperature of 157 °C bulk diffusion of sodium into CIGS occurs. Based on this data, the slower diffusion coefficient in the volume can be described by the Arrhenius equation D{sub Na}{sup V} = 9.7 × 10{sup −9} exp(−0.36 eV/k{sub B}T) cm{sup 2} s{sup −1} and the fast diffusion along the grain boundaries by D{sub Na}{sup GB} = 6.5 × 10{sup −9} exp(−0.21 eV/k{sub B}T) cm{sup 2} s{sup −1}. Hence, we propose that sodium ions do not only passivate grain boundaries, but also act as dopants in the CIGS bulk.

  17. Deep Into the Fibers! Postmortem Diffusion Tensor Imaging in Forensic Radiology.

    Science.gov (United States)

    Flach, Patricia Mildred; Schroth, Sarah; Schweitzer, Wolf; Ampanozi, Garyfalia; Slotboom, Johannes; Kiefer, Claus; Germerott, Tanja; Thali, Michael J; El-Koussy, Marwan

    2015-09-01

    In traumatic brain injury, diffusion-weighted and diffusion tensor imaging of the brain are essential techniques for determining the pathology sustained and the outcome. Postmortem cross-sectional imaging is an established adjunct to forensic autopsy in death investigation. The purpose of this prospective study was to evaluate postmortem diffusion tensor imaging in forensics for its feasibility, influencing factors and correlation to the cause of death compared with autopsy. Postmortem computed tomography, magnetic resonance imaging, and diffusion tensor imaging with fiber tracking were performed in 10 deceased subjects. The Likert scale grading of colored fractional anisotropy maps was correlated to the body temperature and intracranial pathology to assess the diagnostic feasibility of postmortem diffusion tensor imaging and fiber tracking. Optimal fiber tracking (>15,000 fiber tracts) was achieved with a body temperature at 10°C. Likert scale grading showed no linear correlation (P > 0.7) to fiber tract counts. No statistically significant correlation between total fiber count and postmortem interval could be observed (P = 0.122). Postmortem diffusion tensor imaging and fiber tracking allowed for radiological diagnosis in cases with shearing injuries but was impaired in cases with pneumencephalon and intracerebral mass hemorrhage. Postmortem diffusion tensor imaging with fiber tracking provides an exceptional in situ insight "deep into the fibers" of the brain with diagnostic benefit in traumatic brain injury and axonal injuries in the assessment of the underlying cause of death, considering influencing factors for optimal imaging technique.

  18. Computed tomography in the evaluation of thyroid disease

    International Nuclear Information System (INIS)

    Silverman, P.M.; Newman, G.E.; Korobkin, M.; Workman, J.B.; Moore, A.V.; Coleman, R.E.

    1984-01-01

    Traditionally, thyroid imaging has been performed primarily using radionuclide scanning. High-resolution computed tomography (CT) was performed in 18 patients to evaluate the CT appearance of various thyroid abnormalities including diffuse toxic goiter, multinodular goiter, Hashimoto thyroiditis, thyroid adenoma, and malignant thyroid tumors. CT images of the thyroid were correlated with radionuclide scanning, surgical findings, and clinical and laboratory results. CT provided a complementary method for evaluation of the thyroid by defining the morphology of the thyroid gland and more precisely defining the anatomic extent of thyroid abnormalities in relation to the normal structures of the neck and mediastinum

  19. Computed tomography in the evaluation of thyroid disease

    Energy Technology Data Exchange (ETDEWEB)

    Silverman, P.M.; Newman, G.E.; Korobkin, M.; Workman, J.B.; Moore, A.V.; Coleman, R.E.

    1984-05-01

    Traditionally, thyroid imaging has been performed primarily using radionuclide scanning. High-resolution computed tomography (CT) was performed in 18 patients to evaluate the CT appearance of various thyroid abnormalities including diffuse toxic goiter, multinodular goiter, Hashimoto thyroiditis, thyroid adenoma, and malignant thyroid tumors. CT images of the thyroid were correlated with radionuclide scanning, surgical findings, and clinical and laboratory results. CT provided a complementary method for evaluation of the thyroid by defining the morphology of the thyroid gland and more precisely defining the anatomic extent of thyroid abnormalities in relation to the normal structures of the neck and mediastinum.

  20. High-resolution computed tomography of the lungs: the borderlands of normality

    International Nuclear Information System (INIS)

    Dalal, P.U.; Hansell, D.M.

    2006-01-01

    High-resolution computed tomography (HRCT) is now widely used in the assessment of airways and diffuse lung disease. Considerable literature on pathologic correlation has increased the understanding of the signs of disease seen on HRCT. However, neither the significance of subtle individual signs nor the spectrum of HRCT appearances in healthy lungs is well documented. HRCT signs that cause diagnostic uncertainty and the spectrum of findings that exist between definite normality and definite abnormality are discussed. (orig.)

  1. Characterizing Intraorbital Optic Nerve Changes on Diffusion Tensor Imaging in Thyroid Eye Disease Before Dysthyroid Optic Neuropathy.

    Science.gov (United States)

    Lee, Hwa; Lee, Young Hen; Suh, Sang-Il; Jeong, Eun-Kee; Baek, Sehyun; Seo, Hyung Suk

    The aim of this study was to determine whether the optic nerve is affected by thyroid eye disease (TED) before the development of dysthyroid optic neuropathy with diffusion-tensor imaging (DTI). Twenty TED patients and 20 controls were included. The mean, axial, and radial diffusivities and fractional anisotropy (FA) value were measured at the optic nerves in DTI. Extraocular muscle diameters were measured on computed tomography. The diffusivities and FA of the optic nerves were compared between TED and controls and between active and inactive stages of TED. The correlations between these DTI parameters and the clinical features were determined. The mean, axial, and radial diffusivities were lower in TED compared with the controls (P optic nerve before dysthyroid optic neuropathy in TED. The FA, in particular, reflected TED activity and severity.

  2. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  3. Diffuse optical tomography activation in the somatosensory cortex: specific activation by painful vs. non-painful thermal stimuli.

    Directory of Open Access Journals (Sweden)

    Lino Becerra

    2009-11-01

    Full Text Available Pain is difficult to assess due to the subjective nature of self-reporting. The lack of objective measures of pain has hampered the development of new treatments as well as the evaluation of current ones. Functional MRI studies of pain have begun to delineate potential brain response signatures that could be used as objective read-outs of pain. Using Diffuse Optical Tomography (DOT, we have shown in the past a distinct DOT signal over the somatosensory cortex to a noxious heat stimulus that could be distinguished from the signal elicited by innocuous mechanical stimuli. Here we further our findings by studying the response to thermal innocuous and noxious stimuli.Innocuous and noxious thermal stimuli were applied to the skin of the face of the first division (ophthalmic of the trigeminal nerve in healthy volunteers (N = 6. Stimuli temperatures were adjusted for each subject to evoke warm (equivalent to a 3/10 and painful hot (7/10 sensations in a verbal rating scale (0/10 = no/max pain. A set of 26 stimuli (5 sec each was applied for each temperature with inter-stimulus intervals varied between 8 and 15 sec using a Peltier thermode. A DOT system was used to capture cortical responses on both sides of the head over the primary somatosensory cortical region (S1. For the innocuous stimuli, group results indicated mainly activation on the contralateral side with a weak ipsilateral response. For the noxious stimuli, bilateral activation was observed with comparable amplitudes on both sides. Furthermore, noxious stimuli produced a temporal biphasic response while innocuous stimuli produced a monophasic response.These results are in accordance with fMRI and our other DOT studies of innocuous mechanical and noxious heat stimuli. The data indicate the differentiation of DOT cortical responses for pain vs. innocuous stimuli that may be useful in assessing objectively acute pain.

  4. Diffuse metastatic infiltration of a carcinoma into skeletal muscle

    Energy Technology Data Exchange (ETDEWEB)

    Hundt, W.; Braunschweig, R.; Reiser, M. [Dept. of Diagnostic Radiology, Ludwig-Maximilians-Univ., Muenchen (Germany)

    1999-03-01

    Skeletal muscle is one of the most unusual sites of metastasis from any malignancy. We report a patient with rapidly progressive contractures due to metastatic infiltration of a carcinoma of unknown origin into the skeletal muscle. This 61-year-old man presented with a 1-month history of rapidly evolving, painful restriction of mobility of his right arm and his legs. Computed tomography showed diffuse metastatic nodules in all muscles, particularly in the hip abductors. Muscle biopsy revealed extensive infiltration of the muscle with carcinoma cells. (orig.) With 4 figs., 21 refs.

  5. Hydraulic Tomography for Estimating the Diffusivity of Heterogeneous Aquifers Based on Groundwater Response to Tidal Fluctuation in an Artificial Island in Taiwan

    Directory of Open Access Journals (Sweden)

    Jet-Chau Wen

    2018-01-01

    Full Text Available This study investigated the hydraulic properties of the heterogeneous aquifers of an artificial island (Yunlin Offshore Industrial Park in Taiwan. The research was based on the groundwater level response affected by tidal fluctuation using the hydraulic tomography (HT to analyze the hydraulic diffusivity (α. Specifically, the power spectrum ratio of groundwater and tidal fluctuations derived from the Gelhar solution was used to estimate α in homogeneous aquifers; this, however, could not be applied in the artificial island. Next, the spatial distribution of the groundwater level response affected by tidal fluctuation was analyzed and found to be irregular, proving the existence of hydrogeological heterogeneity in the artificial island. Furthermore, the results of the estimated α using the HT showed low error and high correlation, 0.41 m2/hr and 0.83, respectively, between the optimal estimated heterogeneous and reference α fields in the synthetic aquifer. Last, the HT was used in the real tested scenario. By comparing the predicted groundwater levels of the optimal estimated heterogeneous α field and the observed groundwater levels of the real aquifer, it was found that the correlation was higher than 0.99. Therefore, the HT can be used to obtain the optimal estimated heterogeneous α field in the artificial island.

  6. Optical computed tomography for imaging the breast: first look

    Science.gov (United States)

    Grable, Richard J.; Ponder, Steven L.; Gkanatsios, Nikolaos A.; Dieckmann, William; Olivier, Patrick F.; Wake, Robert H.; Zeng, Yueping

    2000-07-01

    The purpose of the study is to compare computed tomography optical imaging with traditional breast imaging techniques. Images produced by computed tomography laser mammography (CTLMTM) scanner are compared with images obtained from mammography, and in some cases ultrasound and/or magnetic resonance imaging (MRI). During the CTLM procedure, a near infrared laser irradiates the breast and an array of photodiodes detectors records light scattered through the breast tissue. The laser and detectors rotate synchronously around the breast to acquire a series of slice data along the coronal place. The procedure is performed without any breast compression or optical matching fluid. Cross-sectional slices of the breast are produced using a reconstruction algorithm. Reconstruction based on the diffusion theory is used to produce cross-sectional slices of the breast. Multiple slice images are combined to produce a three dimensional volumetric array of the imaged breast. This array is used to derive axial and sagittal images of the breast corresponding to cranio-caudal and medio-lateral images used in mammography. Over 200 women and 3 men have been scanned in clinical trials. The most obvious features seen in images produced by the optical tomography scanner are vascularization and significant lesions. Breast features caused by fibrocystic changes and cysts are less obvious. Breast density does not appear to be a significant factor in the quality of the image. We see correlation of the optical image structure with that seen with traditional breast imaging techniques. Further testing is being conducted to explore the sensitivity and specificity of optical tomography of the breast.

  7. Turbocharging Quantum Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blume-Kohout, Robin J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Gamble, John King [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Nielsen, Erik [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Maunz, Peter Lukas Wilhelm [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Scholten, Travis L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Rudinger, Kenneth Michael [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Quantum tomography is used to characterize quantum operations implemented in quantum information processing (QIP) hardware. Traditionally, state tomography has been used to characterize the quantum state prepared in an initialization procedure, while quantum process tomography is used to characterize dynamical operations on a QIP system. As such, tomography is critical to the development of QIP hardware (since it is necessary both for debugging and validating as-built devices, and its results are used to influence the next generation of devices). But tomography suffers from several critical drawbacks. In this report, we present new research that resolves several of these flaws. We describe a new form of tomography called gate set tomography (GST), which unifies state and process tomography, avoids prior methods critical reliance on precalibrated operations that are not generally available, and can achieve unprecedented accuracies. We report on theory and experimental development of adaptive tomography protocols that achieve far higher fidelity in state reconstruction than non-adaptive methods. Finally, we present a new theoretical and experimental analysis of process tomography on multispin systems, and demonstrate how to more effectively detect and characterize quantum noise using carefully tailored ensembles of input states.

  8. High-resolution computed tomography to differentiate chronic diffuse interstitial lung diseases with predominant ground-glass pattern using logical analysis of data

    International Nuclear Information System (INIS)

    Martin, Sophie Grivaud; Brauner, Michel W.; Rety, Frederique; Kronek, Louis-Philippe; Brauner, Nadia; Valeyre, Dominique; Nunes, Hilario; Brillet, Pierre-Yves

    2010-01-01

    We evaluated the performance of high-resolution computed tomography (HRCT) to differentiate chronic diffuse interstitial lung diseases (CDILD) with predominant ground-glass pattern by using logical analysis of data (LAD). A total of 162 patients were classified into seven categories: sarcoidosis (n = 38), connective tissue disease (n = 32), hypersensitivity pneumonitis (n = 18), drug-induced lung disease (n = 15), alveolar proteinosis (n = 12), idiopathic non-specific interstitial pneumonia (n = 10) and miscellaneous (n = 37). First, 40 CT attributes were investigated by the LAD to build up patterns characterising a category. From the association of patterns, LAD determined models specific to each CDILD. Second, data were recomputed by adding eight clinical attributes to the analysis. The 20 x 5 cross-folding method was used for validation. Models could be individualised for sarcoidosis, hypersensitivity pneumonitis, connective tissue disease and alveolar proteinosis. An additional model was individualised for drug-induced lung disease by adding clinical data. No model was demonstrated for idiopathic non-specific interstitial pneumonia and the miscellaneous category. The results showed that HRCT had a good sensitivity (≥64%) and specificity (≥78%) and a high negative predictive value (≥93%) for diseases with a model. Higher sensitivity (≥78%) and specificity (≥89%) were achieved by adding clinical data. The diagnostic performance of HRCT is high and can be increased by adding clinical data. (orig.)

  9. Clinical evaluation of computed tomography in various liver diseases with diffuse pathological alteration

    International Nuclear Information System (INIS)

    Toyoda, Eiichi

    1983-01-01

    Twenty seven cases of acute hepatitis 120 of chronic hepatitis 133 of liver cirrhosis 79 of fatty liver 28 of alcoholic liver injury 5 of intrahepatic cholestasis 22 of obstructive jaundice and 100 normal adults were studied. EMI CT 5005 whole body scanner was used to obtain scan of the liver and spleen, and CT number of them was measured in EMI units, so L/S ratio was calculated by dividing both EMI number. In the patients with obesity, the EMI number of the liver and/or spleen were higher than normal controls. In acute hepatitis, EMI number of the liver, spleen and L/S ratio were no significant differences compared with controls. In chronic hepatitis inactive and active type, EMI number of the liver and spleen were no significant differences between chronic hepatitis and controls, but L/S ratio was lower than that of controls. In cirrhosis of the liver, EMI number of the liver and L/S ratio were lower than that of controls, but EMI number of the spleen had no significant differences compared with controls. In patients with fatty liver, EMI number of the liver and L/S ratio were lower than any other diffuse liver diseases. In alcoholic liver injury had no significant differences from normal controls in liver EMI number, spleen EMI number and L/S ratio. In intrahepatic cholestsis, there was weak inverse corelation between liver EMI number and serum total bilirubin, and in obstructive jaundice strong inverse corelation was seen. In diffuse liver diseases, fatty infiltration, liver cell necrosis, fibrosis or jaundice may decrease the EMI number of the liver and/or L/S ratio, but except for fatty liver, it seems difficult to diagnose the diffuse liver diseases by CT scanner. (J.P.N.)

  10. Transport of neutral solute across articular cartilage: the role of zonal diffusivities.

    Science.gov (United States)

    Arbabi, V; Pouran, B; Weinans, H; Zadpoor, A A

    2015-07-01

    Transport of solutes through diffusion is an important metabolic mechanism for the avascular cartilage tissue. Three types of interconnected physical phenomena, namely mechanical, electrical, and chemical, are all involved in the physics of transport in cartilage. In this study, we use a carefully designed experimental-computational setup to separate the effects of mechanical and chemical factors from those of electrical charges. Axial diffusion of a neutral solute Iodixanol into cartilage was monitored using calibrated microcomputed tomography micro-CT images for up to 48 hr. A biphasic-solute computational model was fitted to the experimental data to determine the diffusion coefficients of cartilage. Cartilage was modeled either using one single diffusion coefficient (single-zone model) or using three diffusion coefficients corresponding to superficial, middle, and deep cartilage zones (multizone model). It was observed that the single-zone model cannot capture the entire concentration-time curve and under-predicts the near-equilibrium concentration values, whereas the multizone model could very well match the experimental data. The diffusion coefficient of the superficial zone was found to be at least one order of magnitude larger than that of the middle zone. Since neutral solutes were used, glycosaminoglycan (GAG) content cannot be the primary reason behind such large differences between the diffusion coefficients of the different cartilage zones. It is therefore concluded that other features of the different cartilage zones such as water content and the organization (orientation) of collagen fibers may be enough to cause large differences in diffusion coefficients through the cartilage thickness.

  11. Prognostic value of interim FDG-PET in R-CHOP-treated diffuse large B-cell lymphoma : Systematic review and meta-analysis

    NARCIS (Netherlands)

    Adams, Hugo J A; Kwee, Thomas C.

    2016-01-01

    This study aimed to systematically review and meta-analyze the prognostic value of interim 18F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) in diffuse large B-cell lymphoma (DLBCL) patients treated with rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisolone

  12. Experimental Study on Bioluminescence Tomography with Multimodality Fusion

    Directory of Open Access Journals (Sweden)

    Yujie Lv

    2007-01-01

    Full Text Available To verify the influence of a priori information on the nonuniqueness problem of bioluminescence tomography (BLT, the multimodality imaging fusion based BLT experiment is performed by multiview noncontact detection mode, which incorporates the anatomical information obtained by the microCT scanner and the background optical properties based on diffuse reflectance measurements. In the reconstruction procedure, the utilization of adaptive finite element methods (FEMs and a priori permissible source region refines the reconstructed results and improves numerical robustness and efficiency. The comparison between the absence and employment of a priori information shows that multimodality imaging fusion is essential to quantitative BLT reconstruction.

  13. Impact of errors in experimental parameters on reconstructed breast images using diffuse optical tomography.

    Science.gov (United States)

    Deng, Bin; Lundqvist, Mats; Fang, Qianqian; Carp, Stefan A

    2018-03-01

    Near-infrared diffuse optical tomography (NIR-DOT) is an emerging technology that offers hemoglobin based, functional imaging tumor biomarkers for breast cancer management. The most promising clinical translation opportunities are in the differential diagnosis of malignant vs. benign lesions, and in early response assessment and guidance for neoadjuvant chemotherapy. Accurate quantification of the tissue oxy- and deoxy-hemoglobin concentration across the field of view, as well as repeatability during longitudinal imaging in the context of therapy guidance, are essential for the successful translation of NIR-DOT to clinical practice. The ill-posed and ill-condition nature of the DOT inverse problem makes this technique particularly susceptible to model errors that may occur, for example, when the experimental conditions do not fully match the assumptions built into the image reconstruction process. To evaluate the susceptibility of DOT images to experimental errors that might be encountered in practice for a parallel-plate NIR-DOT system, we simulated 7 different types of errors, each with a range of magnitudes. We generated simulated data by using digital breast phantoms derived from five actual mammograms of healthy female volunteers, to which we added a 1-cm tumor. After applying each of the experimental error types and magnitudes to the simulated measurements, we reconstructed optical images with and without structural prior guidance and assessed the overall error in the total hemoglobin concentrations (HbT) and in the HbT contrast between the lesion and surrounding area vs. the best-case scenarios. It is found that slight in-plane probe misalignment and plate rotation did not result in large quantification errors. However, any out-of-plane probe tilting could result in significant deterioration in lesion contrast. Among the error types investigated in this work, optical images were the least likely to be impacted by breast shape inaccuracies but suffered the

  14. Computerized tomography

    International Nuclear Information System (INIS)

    Rubashov, I.B.

    1985-01-01

    Operating principle is described for the devices of computerized tomography used in medicine for diagnosis of brain diseases. Computerized tomography is considered as a part of computerized diagnosis, as a part of information science. It is shown that computerized tomography is a real existed field of investigations in medicine and industrial production

  15. Ground-glass opacity in diffuse lung diseases: high-resolution computed tomography-pathology correlation; Opacidades em vidro fosco nas doencas pulmonares difusas: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Maria Lucia de Oliveira; Vianna, Alberto Domingues; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Disciplina de Radiologia; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Patologia]. E-mail: edmarchiori@zipmail.com.br

    2003-12-01

    Ground-glass opacity is a finding frequently seen in high-resolution computed tomography examinations of the chest and is characterized by hazy increased attenuation of lung, however without blurring of bronchial and vascular margins. Due to its un specificity, association with other radiological, clinical and pathological findings must be considered for an accurate diagnostic interpretation. In this paper were reviewed 62 computed tomography examinations of patients with diffuse pulmonary diseases of 14 different etiologies in which ground-glass opacity was the only or the most remarkable finding, and correlated this findings with pathology abnormalities seen on specimens obtained from biopsies or necropsies. In pneumocystosis, ground-glass opacities correlated histologically with alveolar occupation by a foaming material containing parasites, in bronchiole alveolar cell carcinoma with thickening of the alveolar septa and occupation of the lumen by mucus and tumoral cells, in paracoccidioidomycosis with thickening of the alveolar septa, areas of fibrosis and alveolar bronchopneumonia exudate, in sarcoidosis with fibrosis or clustering of granulomas and in idiopathic pulmonary fibrosis with alveolar septa thickening due to fibrosis. Alveolar occupation by blood was found in cases of leptospirosis, idiopathic hemo siderosis, metastatic kidney tumor and invasive aspergillosis whereas oily vacuole were seen in lipoid pneumonia, proteinaceous and lipo proteinaceous material in silico proteinosis and pulmonary alveolar proteinosis, and edematous fluid in cardiac failure. (author)

  16. Correlation of computed tomography, magnetic resonance imaging and clinical outcome in acute carbon monoxide poisoning.

    Science.gov (United States)

    Ozcan, Namik; Ozcam, Giray; Kosar, Pinar; Ozcan, Ayse; Basar, Hulya; Kaymak, Cetin

    2016-01-01

    Carbon monoxide is a toxic gas for humans and is still a silent killer in both developed and developing countries. The aim of this case series was to evaluate early radiological images as a predictor of subsequent neuropsychological sequelae, following carbon monoxide poisoning. After carbon monoxide exposure, early computed tomography scans and magnetic resonance imaging findings of a 52-year-old woman showed bilateral lesions in the globus pallidus. This patient was discharged and followed for 90 days. The patient recovered without any neurological sequela. In a 58-year-old woman exposed to carbon monoxide, computed tomography showed lesions in bilateral globus pallidus and periventricular white matter. Early magnetic resonance imaging revealed changes similar to that like in early tomography images. The patient recovered and was discharged from hospital. On the 27th day of exposure, the patient developed disorientation and memory impairment. Late magnetic resonance imaging showed diffuse hyperintensity in the cerebral white matter. White matter lesions which progress to demyelination and end up in neuropsychological sequelae cannot always be diagnosed by early computed tomography and magnetic resonance imaging in carbon monoxide poisoning. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  17. Fractional Diffusion Equations and Anomalous Diffusion

    Science.gov (United States)

    Evangelista, Luiz Roberto; Kaminski Lenzi, Ervin

    2018-01-01

    Preface; 1. Mathematical preliminaries; 2. A survey of the fractional calculus; 3. From normal to anomalous diffusion; 4. Fractional diffusion equations: elementary applications; 5. Fractional diffusion equations: surface effects; 6. Fractional nonlinear diffusion equation; 7. Anomalous diffusion: anisotropic case; 8. Fractional Schrödinger equations; 9. Anomalous diffusion and impedance spectroscopy; 10. The Poisson–Nernst–Planck anomalous (PNPA) models; References; Index.

  18. Diffuse infiltrating retinoblastoma invading subarachnoid space

    Directory of Open Access Journals (Sweden)

    Kase S

    2011-06-01

    Full Text Available Satoru Kase1, Kazuhiko Yoshida1, Shigenobu Suzuki2, Koh-ichi Ohshima3, Shigeaki Ohno4, Susumu Ishida11Department of Ophthalmology, Hokkaido University Graduate School of Medicine, Sapporo; 2Department of Ophthalmic Oncology, National Cancer Center Hospital, Tokyo; 3Section of Ophthalmology, Okayama Medical Center, Okayama; 4Department of Ocular Inflammation and Immunology, Hokkaido University Graduate School of Medicine, Sapporo, JapanAbstract: We report herein an unusual case of diffuse infiltrating retinoblastoma involving the brain, which caused a patient’s death 27 months after enucleation. An eight-year-old boy complained of blurred vision in his right eye (OD in October 2006. Funduscopic examination showed optic disc swelling, dense whitish vitreous opacity, and an orange-colored subretinal elevated lesion adjacent to the optic disc. Fluorescein angiography revealed hyperfluorescence in the peripapillary region at an early-phase OD. Because the size of the subretinal lesion and vitreous opacity gradually increased, he was referred to us. His visual acuity was 20/1000 OD on June 20, 2007. Slit-lamp biomicroscopy showed a dense anterior vitreous opacity. Ophthalmoscopically, the subretinal orange-colored area spread out until reaching the mid peripheral region. A B-mode sonogram and computed tomography showed a thick homogeneous lesion without calcification. Gadolinium-enhanced magnetic resonance imaging showed a markedly enhanced appearance of the underlying posterior retina. Enucleation of the right eye was performed nine months after the initial presentation. Histopathology demonstrated retinal detachment and a huge choroidal mass invading the optic nerve head. The tumor was consistent with diffuse infiltrating retinoblastoma. The patient died due to brain involvement 27 months after enucleation. Ophthalmologists should be aware that diffuse infiltrating retinoblastoma may show an unfavorable course if its diagnosis is delayed

  19. WE-H-206-01: Photoacoustic Tomography: Multiscale Imaging From Organelles to Patients by Ultrasonically Beating the Optical Diffusion Limit

    International Nuclear Information System (INIS)

    Wang, L.

    2016-01-01

    Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly

  20. WE-H-206-01: Photoacoustic Tomography: Multiscale Imaging From Organelles to Patients by Ultrasonically Beating the Optical Diffusion Limit

    Energy Technology Data Exchange (ETDEWEB)

    Wang, L. [Washington University (United States)

    2016-06-15

    Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly

  1. The diagnostic value of cranial computerized tomography in exogenous psychoses and mental disorders associated with organic diseases

    International Nuclear Information System (INIS)

    Strobl, G.; Reisner, Th.; Zeiler, K.; Vienna Univ.

    1980-01-01

    205 patients hospitalized in a psychiatric department were subjected to cranial computerized tomography. The diagnosis on discharge according to the ICD key in each case was ''psychoses or mental disorders associated with physical conditions''. Pathological findings were obtained in 67.8% of the patients. In the case of space-occupying lesions the connection between psychiatric symptoms and syndromes and the underlying organic disease is obvious. Moreover, with inflammatory, vascular or traumatic diseases, a relationship to focal lesions found on the computer tomography appears likely if backed by appropriate neurological indications in the history or an clinical examinations. However, when alterations signifying diffuse brain atrophy are obtained on computer tomography any connections with psychiatric features should be very critically evaluated and, in individual cases, such connections had better not be looked for at all. Especially in cases of psychoses or mental disorders associated with physical conditions cranial computerized tomography is of high diagnostic value and the indications for its implementation in these cases should be judged very leniently. (author)

  2. A rare case of unilateral diffuse melanocytic proliferation

    Directory of Open Access Journals (Sweden)

    Guruprasad Ayachit

    2018-01-01

    Full Text Available A 67-year-old woman presented with metamorphopsia in the right eye. Leopard mottling was seen temporal to the fovea oculus dexter with corresponding hyper- and hypo-autofluorescent lesions on fundus autofluorescence. Spectral domain-optical coherence tomography revealed hyperreflective dots in the retinal pigment epithelium and choroid with subretinal fluid (SRF. Intravitreal bevacizumab was administered with which SRF resolved, albeit with increase in the areas of mottling. The patient was diagnosed to have metastatic ductal carcinoma of the right breast. It is important to bear in mind that the well-known entity of bilateral diffuse uveal melanocytic proliferation can rarely present unilaterally.

  3. Anisotropic conductivity tensor imaging in MREIT using directional diffusion rate of water molecules

    International Nuclear Information System (INIS)

    Kwon, Oh In; Jeong, Woo Chul; Sajib, Saurav Z K; Kim, Hyung Joong; Woo, Eung Je

    2014-01-01

    Magnetic resonance electrical impedance tomography (MREIT) is an emerging method to visualize electrical conductivity and/or current density images at low frequencies (below 1 KHz). Injecting currents into an imaging object, one component of the induced magnetic flux density is acquired using an MRI scanner for isotropic conductivity image reconstructions. Diffusion tensor MRI (DT-MRI) measures the intrinsic three-dimensional diffusion property of water molecules within a tissue. It characterizes the anisotropic water transport by the effective diffusion tensor. Combining the DT-MRI and MREIT techniques, we propose a novel direct method for absolute conductivity tensor image reconstructions based on a linear relationship between the water diffusion tensor and the electrical conductivity tensor. We first recover the projected current density, which is the best approximation of the internal current density one can obtain from the measured single component of the induced magnetic flux density. This enables us to estimate a scale factor between the diffusion tensor and the conductivity tensor. Combining these values at all pixels with the acquired diffusion tensor map, we can quantitatively recover the anisotropic conductivity tensor map. From numerical simulations and experimental verifications using a biological tissue phantom, we found that the new method overcomes the limitations of each method and successfully reconstructs both the direction and magnitude of the conductivity tensor for both the anisotropic and isotropic regions. (paper)

  4. Contemporary imaging of mild TBI: the journey toward diffusion tensor imaging to assess neuronal damage.

    Science.gov (United States)

    Fox, W Christopher; Park, Min S; Belverud, Shawn; Klugh, Arnett; Rivet, Dennis; Tomlin, Jeffrey M

    2013-04-01

    To follow the progression of neuroimaging as a means of non-invasive evaluation of mild traumatic brain injury (mTBI) in order to provide recommendations based on reproducible, defined imaging findings. A comprehensive literature review and analysis of contemporary published articles was performed to study the progression of neuroimaging findings as a non-invasive 'biomarker' for mTBI. Multiple imaging modalities exist to support the evaluation of patients with mTBI, including ultrasound (US), computed tomography (CT), single photon emission computed tomography (SPECT), positron emission tomography (PET), and magnetic resonance imaging (MRI). These techniques continue to evolve with the development of fractional anisotropy (FA), fiber tractography (FT), and diffusion tensor imaging (DTI). Modern imaging techniques, when applied in the appropriate clinical setting, may serve as a valuable tool for diagnosis and management of patients with mTBI. An understanding of modern neuroanatomical imaging will enhance our ability to analyse injury and recognize the manifestations of mTBI.

  5. Minamata disease demonstrated by computed tomography

    International Nuclear Information System (INIS)

    Matsumoto, S.C.; Okajima, T.; Inayoshi, S.; Ueno, H.

    1988-01-01

    Computed tomography was studied in the patients with Minamata disease, a methylmercury poisoning caused by the ingestion of contaminated sea foods. The characteristic changes in the acquired cases were atrophy of the visual calcarine cortex and of the cerebellar vermis and or hemisphere. Marked atrophy of the calcarine cortex produced the sac-shaped low density areas between the occipital lobes and diffuse and marked cerebellar atrophy with enlargement of the fourth ventricle and cisterns of the posterior fossa produced a shrunken image on CT. Morphometric analysis confirmed these findings. In the fetal cases, the changes on CT were slight and no definite atrophy was demonstrated in either the calcarine cortex or the cerebellum. Morphometric analysis disclosed an increase of size of the middle portions of the lateral ventricle and the third and fourth ventricles. (orig.)

  6. Implementation of a computationally efficient least-squares algorithm for highly under-determined three-dimensional diffuse optical tomography problems.

    Science.gov (United States)

    Yalavarthy, Phaneendra K; Lynch, Daniel R; Pogue, Brian W; Dehghani, Hamid; Paulsen, Keith D

    2008-05-01

    Three-dimensional (3D) diffuse optical tomography is known to be a nonlinear, ill-posed and sometimes under-determined problem, where regularization is added to the minimization to allow convergence to a unique solution. In this work, a generalized least-squares (GLS) minimization method was implemented, which employs weight matrices for both data-model misfit and optical properties to include their variances and covariances, using a computationally efficient scheme. This allows inversion of a matrix that is of a dimension dictated by the number of measurements, instead of by the number of imaging parameters. This increases the computation speed up to four times per iteration in most of the under-determined 3D imaging problems. An analytic derivation, using the Sherman-Morrison-Woodbury identity, is shown for this efficient alternative form and it is proven to be equivalent, not only analytically, but also numerically. Equivalent alternative forms for other minimization methods, like Levenberg-Marquardt (LM) and Tikhonov, are also derived. Three-dimensional reconstruction results indicate that the poor recovery of quantitatively accurate values in 3D optical images can also be a characteristic of the reconstruction algorithm, along with the target size. Interestingly, usage of GLS reconstruction methods reduces error in the periphery of the image, as expected, and improves by 20% the ability to quantify local interior regions in terms of the recovered optical contrast, as compared to LM methods. Characterization of detector photo-multiplier tubes noise has enabled the use of the GLS method for reconstructing experimental data and showed a promise for better quantification of target in 3D optical imaging. Use of these new alternative forms becomes effective when the ratio of the number of imaging property parameters exceeds the number of measurements by a factor greater than 2.

  7. Sagittal reconstruction computed tomography in metrizamide cisternography. Useful diagnostic procedure for malformations in craniovertebral junction and posterior fossa

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, H.; Okita, N.; Fujii, T.; Yoshioka, M.; Saito, H. (Tohoku Univ., Sendai (Japan). School of Medicine)

    1982-08-01

    We studied the sagittal reconstruction technique in computed tomography with metrizamide. Ten ml of metrizamide, 170 mg iodine/ml in concentration, were injected by lumbar puncture. After diffusion of the injected metrizamide, axial computed tomograms were taken by thin slice width (5 mm) with overlapped technique. Then electrical sagittal reconstruction was carried out by optioned software. Injection of metrizamide, non-ionic water soluble contrast media, made clear contrasts among bone, brain parenchyma and cerebrospinal fluid with computed tomography. Sagittal reconstruction technique could reveal more precise details and accurate anatomical relations than ordinary axial computed tomography. This technique was applied on 3 cases (Arnold-Chiari malformation, large cisterna magna and partial agenesis cerebellar vermis), which demonstrated a useful diagnostic procedure for abnormalities of craniovertebral junction and posterior fossa. The adverse reactions of metrizamide were negligible in our series.

  8. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  9. Computed Tomography Features of Incidentally Detected Diffuse Thyroid Disease

    Directory of Open Access Journals (Sweden)

    Myung Ho Rho

    2014-01-01

    Full Text Available Objective. This study aimed to evaluate the CT features of incidentally detected DTD in the patients who underwent thyroidectomy and to assess the diagnostic accuracy of CT diagnosis. Methods. We enrolled 209 consecutive patients who received preoperative neck CT and subsequent thyroid surgery. Neck CT in each case was retrospectively investigated by a single radiologist. We evaluated the diagnostic accuracy of individual CT features and the cut-off CT criteria for detecting DTD by comparing the CT features with histopathological results. Results. Histopathological examination of the 209 cases revealed normal thyroid (n=157, Hashimoto thyroiditis (n=17, non-Hashimoto lymphocytic thyroiditis (n=34, and diffuse hyperplasia (n=1. The CT features suggestive of DTD included low attenuation, inhomogeneous attenuation, increased glandular size, lobulated margin, and inhomogeneous enhancement. ROC curve analysis revealed that CT diagnosis of DTD based on the CT classification of “3 or more” abnormal CT features was superior. When the “3 or more” CT classification was selected, the sensitivity, specificity, positive and negative predictive values, and accuracy of CT diagnosis for DTD were 55.8%, 95.5%, 80.6%, 86.7%, and 85.6%, respectively. Conclusion. Neck CT may be helpful for the detection of incidental DTD.

  10. A cost-effective LED and photodetector based fast direct 3D diffuse optical imaging system

    Science.gov (United States)

    Saikia, Manob Jyoti; Manjappa, Rakesh; Kanhirodan, Rajan

    2017-07-01

    A cost-effective and high-speed 3D diffuse optical tomography system using high power LED light sources and silicon photodetectors has been designed and built, that can continuously scan and reconstruct spectroscopic images at a frame rate of 2 fps. The system is experimentally validated with tissue mimicking cylindrical resin phantom having light absorbing inhomogeneities of different size, shape and contrast, and at different locations.

  11. Tomography

    International Nuclear Information System (INIS)

    1985-01-01

    Already widely accepted in medicine, tomography can also be useful in industry. The theory behind tomography and a demonstration of the technique to inspect a motorcycle carburetor is presented. To demonstrate the potential of computer assisted tomography (CAT) to accurately locate defects in three dimensions, a sectioned 5 cm gate valve with a shrink cavity made visible by the sectioning was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +-1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  12. Investigation of the self tempering effect of martensite by means of atom probe tomography

    International Nuclear Information System (INIS)

    Sackl, Stephanie; Clemens, Helmut; Primig, Sophie

    2015-01-01

    Self-tempering effects can be observed in steels with relatively high martensite start temperatures. After the formation of the first martensitic laths, carbon is able to diffuse in these laths during cooling, which can be attributed to sufficiently high temperatures. This effect cannot be observed in laths formed at lower temperatures. In steels containing up to 0.2 m.-% carbon, up to 90 % of the carbon atoms in the martensite segregate to dislocations during quenching. Due to its atomic resolution and sensitivity with respect to light elements, atom probe tomography is very well suited for the investigation of this phenomenon. In this study, the self-tempering effect in a quenched and tempered steel 42CrMo4 with a martensite start temperature of 310 C is investigated by means of atom probe tomography.

  13. Prognostic impact of pre-transplantation computed tomography and 67gallium scanning in chemosensitive diffuse large B cell lymphoma patients undergoing hematopoietic stem-cell transplantation

    International Nuclear Information System (INIS)

    Escobar, Ignacio G.; Alonso, Pilar T.; Barrigon, Dolores C.; Perez-Simon, Jose A.; Mateos Manteca, Maria V.; San Miguel Izquierdo, Jesus F.

    2008-01-01

    In the present study, we evaluated computed tomography (CT) and 67 gallium scanning ( 67 Ga scan) pre-transplant as prognostic factors for overall survival (OS) and event-free survival (EFS) in patients with diffuse large B cell lymphoma, undergoing high-dose chemotherapy and stem-cell transplantation. Forty-two patients were included. Of these, 9 (21%) had both positive CT and 67 Ga scans, 17 (41%) negative results with both techniques, and 16 (38%) positive CT/negative 67 Ga scan. Whole-body planar imaging and single-photon emission computed tomography (SPECT) were performed 72 h after an intravenous administration of 67 Ga citrate measuring between 7 mCi and 10 mCi (259-370 MBq). Patients with positive CT/positive 67 Ga scan had a significantly worse EFS and OS at 5 years than those with negative 67 Ga scan regardless of whether it was associated with a positive or a negative CT scan (29% and 16% vs. 81% and 93% vs. 88% and 100%, respectively, P 67 Ga scan and those with positive CT/negative 67 Ga scan, with an EFS and OS at 5 years of 88% versus 81% and 100% versus 93%, respectively. In multivariate analysis, the presence of a pre-transplant positive CT/ 67 Ga scans adversely influenced both EFS and OS [HR 8, 95% confidence interval (CI) (1.4-38), P=0.03 and HR 2; 95% CI (1.3-8), P=0.02, respectively]. 67 Ga scan helps to identify, in the pre-transplant evaluation, two groups with a different outcome: one group of patients with positive CT and negative 67 Ga scans pre-transplant, who showed a favorable outcome with a low rate of relapse, and the other group of patients with both positive CT and 67 Ga scans pre-transplant, who showed a poor prognosis and did not benefit from autologous stem-cell transplantation. They should have been offered other therapeutic strategies. (author)

  14. Differentiating primary CNS lymphoma from glioblastoma multiforme: assessment using arterial spin labeling, diffusion-weighted imaging, and {sup 18}F-fluorodeoxyglucose positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Koji; Yoshiura, Takashi; Hiwatashi, Akio; Togao, Osamu; Abe, Koichiro; Kikuchi, Kazufumi; Maruoka, Yasuhiro; Honda, Hiroshi [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Yoshimoto, Koji; Mizoguchi, Masahiro [Kyushu University, Department of Neurosurgery, Graduate School of Medical Sciences, Fukuoka (Japan); Suzuki, Satoshi O.; Iwaki, Toru [Kyushu University, Department of Neuropathology, Graduate School of Medical Sciences, Fukuoka (Japan)

    2013-02-15

    Our purpose was to evaluate the diagnostic performance of arterial spin labeling (ASL) perfusion imaging, diffusion-weighted imaging (DWI), and {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET) in differentiating primary central nervous system lymphomas (PCNSLs) from glioblastoma multiformes (GBMs). Fifty-six patients including 19 with PCNSL and 37 with GBM were retrospectively studied. From the ASL data, an absolute tumor blood flow (aTBF) and a relative tumor blood flow (rTBF) were obtained within the enhancing portion of each tumor. In addition, the minimum apparent diffusion coefficient (ADCmin) and the maximum standard uptake value (SUVmax) were obtained from DWI and FDG-PET data, respectively. Each of the four parameters was compared between PCNSLs and GBMs using Kruskal-Wallis test. The performance in discriminating between PCNSLs and GBMs was evaluated using the receiver-operating characteristics analysis. Area-under-the-curve (AUC) values were compared among the four parameters using a nonparametric method. The aTBF, rTBF, and ADCmin were significantly higher in GBMs (mean aTBF {+-} SD = 91.6 {+-} 56.0 mL/100 g/min, mean rTBF {+-} SD = 2.61 {+-} 1.61, mean ADCmin {+-} SD = 0.78 {+-} 0.19 x 10{sup -3} mm{sup 2}/s) than in PCNSLs (mean aTBF {+-} SD = 37.3 {+-} 10.5 mL/100 g/min, mean rTBF {+-} SD = 1.24 {+-} 0.37, mean ADCmin {+-} SD = 0.61 {+-} 0.13 x 10{sup -3} mm{sup 2}/s) (p < 0.005, respectively). In addition, SUVmax was significantly lower in GBMs (mean {+-} SD = 13.1 {+-} 6.34) than in PCNSLs (mean {+-} SD = 22.5 {+-} 7.83) (p < 0.005). The AUC for aTBF (0.888) was higher than those for rTBF (0.810), ADCmin (0.768), and SUVmax (0.848), although their difference was not statistically significant. ASL perfusion imaging is useful for differentiating PCNSLs from GBMs as well as DWI and FDG-PET. (orig.)

  15. Multidetector Computed Tomography in the Preoperative Workup of Hilar Cholangiocarcinoma

    International Nuclear Information System (INIS)

    Kim, Hyoung Jung; Lee, Dong Ho; Lim, Joo Won; Ko, Young Tae

    2009-01-01

    Hilar cholangiocarcinoma is associated with a dismal prognosis; however, curative resection may offer a chance of cure. Various factors should be considered in the surgical planning for curative resection. These factors include extent of bile duct involvement, relationship between portal vein and tumor involvement, diffuse hepato duodenal ligament infiltration, vascular invasion, lymph node metastasis, peritoneal seeding, and hepatic volume. Using high-quality volume data from multidetector-row computed tomography (MDCT) and adequate postprocessing images, radiologists can provide various types of information, imperative for curative resection of a hilar cholangiocarcinoma. This review illustrates the role of MDCT in the preoperative workup of hilar cholangiocarcinoma

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  17. Diffuse large B-cell lymphoma in the era of precision oncology: How imaging is helpful

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Hina J.; Keraliya, Abhishek R.; Lele, Vikram R.; Tirumani, Sree Harsha; DiPiro, Pamela J.; Jagannathan, Jyothi P. [Dept. of Imaging, Dana Farber Cancer Institute, Harvard Medical School, Boston (United States)

    2017-01-15

    Diffuse large B cell lymphoma (DLBCL) is the most common histological subtype of Non-Hodgkin's lymphoma. As treatments continues to evolve, so do imaging strategies, and positron emission tomography (PET) has emerged as the most important imaging tool to guide oncologists in the diagnosis, staging, response assessment, relapse/recurrence detection,and therapeutic decision making of DLBCL. Other imaging modalities including magnetic resonance imaging (MRI), computed tomography (CT), ultrasound, and conventional radiography are also used in the evaluation of lymphoma. MRI is useful for nervous system and musculoskeletal system involvement and is emerging as a radiation free alternative to PET/CT. This article provides a comprehensive review of both the functional and morphological imaging modalities, available in the management of DLBCL.

  18. Diffusion

    International Nuclear Information System (INIS)

    Kubaschewski, O.

    1983-01-01

    The diffusion rate values of titanium, its compounds and alloys are summarized and tabulated. The individual chemical diffusion coefficients and self-diffusion coefficients of certain isotopes are given. Experimental methods are listed which were used for the determination of diffusion coefficients. Some values have been taken over from other studies. Also given are graphs showing the temperature dependences of diffusion and changes in the diffusion coefficient with concentration changes

  19. Correlation between tissue metabolism and cellularity assessed by standardized uptake value and apparent diffusion coefficient in peritoneal metastasis.

    Science.gov (United States)

    Yu, Xue; Lee, Elaine Yuen Phin; Lai, Vincent; Chan, Queenie

    2014-07-01

    To evaluate the correlation between standardized uptake value (SUV) (tissue metabolism) and apparent diffusion coefficient (ADC) (water diffusivity) in peritoneal metastases. Patients with peritoneal dissemination detected on (18)F-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) were prospectively recruited for MRI examinations with informed consent and the study was approved by the local Institutional Review Board. FDG-PET/CT, diffusion-weighted imaging (DWI), MRI, and DWI/MRI images were independently reviewed by two radiologists based on visual analysis. SUVmax/SUVmean and ADCmin/ADCmean were obtained manually by drawing ROIs over the peritoneal metastases on FDG-PET/CT and DWI, respectively. Diagnostic characteristics of each technique were evaluated. Pearson's coefficient and McNemar and Kappa tests were used for statistical analysis. Eight patients were recruited for this prospective study and 34 peritoneal metastases were evaluated. ADCmean was significantly and negatively correlated with SUVmax (r = -0.528, P = 0.001) and SUVmean (r = -0.548, P = 0.001). ADCmin had similar correlation with SUVmax (r = -0.508, P = 0.002) and SUVmean (r = -0.513, P = 0.002). DWI/MRI had high diagnostic performance (accuracy = 98%) comparable to FDG-PET/CT, in peritoneal metastasis detection. Kappa values were excellent for all techniques. There was a significant inverse correlation between SUV and ADC. © 2013 Wiley Periodicals, Inc.

  20. Ultrasound-guided diffuse optical tomography (DOT) of invasive breast carcinoma: Does tumour total haemoglobin concentration contribute to the prediction of axillary lymph node status?

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Qingli, E-mail: qinglizhu@gmail.com [Department of Diagnostic Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1, Dongcheng District, Beijing 100730 (China); Xiao, Mengsu, E-mail: xiaomengsu_2000@sina.com [Department of Diagnostic Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1, Dongcheng District, Beijing 100730 (China); You, Shanshan, E-mail: shanshan_0531@sina.com [Department of Diagnostic Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1, Dongcheng District, Beijing 100730 (China); Zhang, Jing, E-mail: zhang.jing1029@163.com [Department of Diagnostic Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1, Dongcheng District, Beijing 100730 (China); Jiang, Yuxin, E-mail: yuxinjiangxh@yahoo.com.cn [Department of Diagnostic Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1, Dongcheng District, Beijing 100730 (China); Lai, Xingjian, E-mail: lxjpumch@yahoo.com.cn [Department of Diagnostic Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1, Dongcheng District, Beijing 100730 (China); Dai, Qing, E-mail: qingdai_2000@yahoo.com [Department of Diagnostic Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Shuaifuyuan 1, Dongcheng District, Beijing 100730 (China)

    2012-11-15

    Objectives: To prospectively study the ultrasound-guided near-infrared diffuse optical tomography (DOT) findings of the total haemoglobin concentration (THC) detected in invasive breast carcinomas and its contribution to the prediction of axillary lymph node (LN) status. Methods: A total of 195 invasive breast carcinomas were prospectively studied with DOT before surgery. Lumpectomy or mastectomy with full axillary nodal dissection was performed. Tumour size and THC level were correlated with LN status by a logistic regression analysis. Results: One hundred twenty-four patients (63.59%) was LN(-) and 71 (36.41%) was LN(+). The average THC was significantly higher in the LN(+) group than in the LN(-) group (252.94 {+-} 69.19 {mu}mol/L versus 203.86 {+-} 83.13 {mu}mol/L, P = 0.01). A multivariate analysis showed an independent relationship between the probability of axillary metastasis, elevated THC level (P = 0.01), and tumour size (P = 0.001). The odds ratio with THC {>=} 140 {mu}mol/L was 13.651 (1.781-104.560), whereas that of tumour size with a 1 cm increment was only 1.777 (1.283-2.246). Conclusions: The THC level and the tumour size are independent and preoperative predictors of axillary nodal status; these variables may improve the diagnosis of patients with lymph node metastasis.

  1. Dysphagia due to Diffuse Idiopathic Skeletal Hyperostosis

    Directory of Open Access Journals (Sweden)

    Masafumi Ohki

    2012-01-01

    Full Text Available Diffuse idiopathic skeletal hyperostosis (DISH is usually asymptomatic. However, rarely, it causes dysphagia, hoarseness, dyspnea, snoring, stridor, and laryngeal edema. Herein, we present a patient with DISH causing dysphagia. A 70-year-old man presented with a 4-month history of sore throat, dysphagia, and foreign body sensation. Flexible laryngoscopy revealed a leftward-protruding posterior wall in the hypopharynx. Computed tomography and magnetic resonance imaging revealed a bony mass pushing, anteriorly, on the posterior hypopharyngeal wall. Ossification included an osseous bridge involving 5 contiguous vertebral bodies. Dysphagia due to DISH was diagnosed. His symptoms were relieved by conservative therapy using anti-inflammatory drugs. However, if conservative therapy fails and symptoms are severe, surgical treatments must be considered.

  2. Evolution of porosity and diffusivity associated with chemical weathering of a basalt clast

    Energy Technology Data Exchange (ETDEWEB)

    Navarre-Sitchler, A.; Steefel, C.I.; Yang, L.; Tomutsa, L.; Brantley, S.L.

    2009-02-15

    Weathering of rocks as a result of exposure to water and the atmosphere can cause significant changes in their chemistry and porosity. In low-porosity rocks, such as basalts, changes in porosity, resulting from chemical weathering, are likely to modify the rock's effective diffusivity and permeability, affecting the rate of solute transport and thus potentially the rate of overall weathering to the extent that transport is the rate limiting step. Changes in total porosity as a result of mineral dissolution and precipitation have typically been used to calculate effective diffusion coefficients through Archie's law for reactive transport simulations of chemical weathering, but this approach fails to account for unconnected porosity that does not contribute to transport. In this study, we combine synchrotron X-ray microcomputed tomography ({mu}CT) and laboratory and numerical diffusion experiments to examine changes in both total and effective porosity and effective diffusion coefficients across a weathering interface in a weathered basalt clast from Costa Rica. The {mu}CT data indicate that below a critical value of {approx}9%, the porosity is largely unconnected in the basalt clast. The {mu}CT data were further used to construct a numerical pore network model to determine upscaled, effective diffusivities as a function of total porosity (ranging from 3 to 30%) for comparison with diffusivities determined in laboratory tracer experiments. By using effective porosity as the scaling parameter and accounting for critical porosity, a model is developed that accurately predicts continuum-scale effective diffusivities across the weathering interface of the basalt clast.

  3. Variabilities of Magnetic Resonance Imaging-, Computed Tomography-, and Positron Emission Tomography-Computed Tomography-Based Tumor and Lymph Node Delineations for Lung Cancer Radiation Therapy Planning.

    Science.gov (United States)

    Karki, Kishor; Saraiya, Siddharth; Hugo, Geoffrey D; Mukhopadhyay, Nitai; Jan, Nuzhat; Schuster, Jessica; Schutzer, Matthew; Fahrner, Lester; Groves, Robert; Olsen, Kathryn M; Ford, John C; Weiss, Elisabeth

    2017-09-01

    To investigate interobserver delineation variability for gross tumor volumes of primary lung tumors and associated pathologic lymph nodes using magnetic resonance imaging (MRI), and to compare the results with computed tomography (CT) alone- and positron emission tomography (PET)-CT-based delineations. Seven physicians delineated the tumor volumes of 10 patients for the following scenarios: (1) CT only, (2) PET-CT fusion images registered to CT ("clinical standard"), and (3) postcontrast T1-weighted MRI registered with diffusion-weighted MRI. To compute interobserver variability, the median surface was generated from all observers' contours and used as the reference surface. A physician labeled the interface types (tumor to lung, atelectasis (collapsed lung), hilum, mediastinum, or chest wall) on the median surface. Contoured volumes and bidirectional local distances between individual observers' contours and the reference contour were analyzed. Computed tomography- and MRI-based tumor volumes normalized relative to PET-CT-based volumes were 1.62 ± 0.76 (mean ± standard deviation) and 1.38 ± 0.44, respectively. Volume differences between the imaging modalities were not significant. Between observers, the mean normalized volumes per patient averaged over all patients varied significantly by a factor of 1.6 (MRI) and 2.0 (CT and PET-CT) (P=4.10 × 10 -5 to 3.82 × 10 -9 ). The tumor-atelectasis interface had a significantly higher variability than other interfaces for all modalities combined (P=.0006). The interfaces with the smallest uncertainties were tumor-lung (on CT) and tumor-mediastinum (on PET-CT and MRI). Although MRI-based contouring showed overall larger variability than PET-CT, contouring variability depended on the interface type and was not significantly different between modalities, despite the limited observer experience with MRI. Multimodality imaging and combining different imaging characteristics might be the best approach to define

  4. NEAR-INFRARED AUTOFLUORESCENCE IN BILATERAL DIFFUSE UVEAL MELANOCYTIC PROLIFERATION ASSOCIATED WITH ESOPHAGEAL CARCINOMA AND CHOROIDAL METASTASIS.

    Science.gov (United States)

    Golshahi, Azadeh; Bornfeld, Norbert; Weinitz, Silke; Kellner, Ulrich

    2016-01-01

    To investigate the advantage of near-infrared autofluorescence (787 nm) for the detection of melanocytic lesions in a patient with bilateral diffuse uveal melanocytic proliferation in association with esophageal carcinoma complicated by most likely unilateral choroidal metastasis. In this retrospective case report, a 55-year-old woman referred for the evaluation of sudden visual loss underwent normal ophthalmological evaluation and, in addition, was examined with near-infrared reflectance, near-infrared autofluorescence, fundus autofluorescence (Heidelberg Retina Angiograph II [HRA2; Heidelberg Engineering]), spectral domain optical coherence tomography (Spectralis OCT; Heidelberg Engineering), and multifocal electroretinography (RetiScan; Roland Consult). The patient had been diagnosed with esophageal carcinoma 3 months before the onset of visual symptoms. The visual acuity was 20/40 in the right eye and 20/20 in the left eye. Bilateral patchy melanocytic proliferation was detected on ophthalmoscopy. The extent of lesions was best detected with near-infrared reflectance and near-infrared autofluorescence, whereas fundus autofluorescence and spectral domain optical coherence tomography did not reveal alterations of the outer retina or retinal pigment epithelium in this early stage of bilateral diffuse uveal melanocytic proliferation. The right eye showed in addition to the findings on the left eye choroidal folds in the fovea and an elevated lesion inferotemporal of the fovea suspicious of a choroidal metastasis. In the B-scan ultrasonography, a homogenous lesion was seen. Spectral domain optical coherence tomography demonstrated a mild accumulation of subretinal fluid adjacent to and over the choroidal metastasis. Transretinal biopsy of this elevated lesion revealed a low differentiated carcinoma of squamous epithelium, compatible with choroidal metastasis of the esophageal carcinoma. The choroidal metastasis increased within 3 months after the first visit. The

  5. Comparison of some methods for analyzing the optical properties of molecular aggregates; Comparaison de quelques methodes d'analyse des proprietes optiques des agregats moleculaires

    Energy Technology Data Exchange (ETDEWEB)

    Thiery, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    This report compares the application both of the exciton theory and of the polarizability theory to the study of the optical properties of dimers made up of two identical molecules having only one excited level when separate, and which are held together in the dimer only by Van der Waals forces to the exclusion of any covalent bonding. Using this theoretical basis, the author gives an interpretation of the changes in the spectrum of aqueous NN' diethyl-cyanine solutions as a function of concentration, and stresses the present lack of experimental data necessary for understanding of the mechanism of the hypochromia of nucleic acids. (author) [French] Ce rapport compare l'application, d'une part de la theorie des excitons, d'autre part de la theorie des polarisabilites a l'etude des proprietes optiques de dimeres composees de deux molecules identiques ne possedant, lorsqu'elles sont prises isolement, qu'un seul niveau excite, et qui sont unies l'une a l'autre, au sein du dimere, par des forces de Van der Waals a l'exclusion de toute liaison covalente. Sur ces bases theoriques, l'auteur donne une interpretation de l'evolution du spectre de solutions aqueuses de NN' diethylcyanine en fonction de la concentration et souligne l'insuffisance actuelle des donnees experimentales necessaires a la comprehension du mecanisme de l'hypochromisme des acides nucleiques. (auteur)

  6. Diffusion archeology for diffusion progression history reconstruction.

    Science.gov (United States)

    Sefer, Emre; Kingsford, Carl

    2016-11-01

    Diffusion through graphs can be used to model many real-world processes, such as the spread of diseases, social network memes, computer viruses, or water contaminants. Often, a real-world diffusion cannot be directly observed while it is occurring - perhaps it is not noticed until some time has passed, continuous monitoring is too costly, or privacy concerns limit data access. This leads to the need to reconstruct how the present state of the diffusion came to be from partial diffusion data. Here, we tackle the problem of reconstructing a diffusion history from one or more snapshots of the diffusion state. This ability can be invaluable to learn when certain computer nodes are infected or which people are the initial disease spreaders to control future diffusions. We formulate this problem over discrete-time SEIRS-type diffusion models in terms of maximum likelihood. We design methods that are based on submodularity and a novel prize-collecting dominating-set vertex cover (PCDSVC) relaxation that can identify likely diffusion steps with some provable performance guarantees. Our methods are the first to be able to reconstruct complete diffusion histories accurately in real and simulated situations. As a special case, they can also identify the initial spreaders better than the existing methods for that problem. Our results for both meme and contaminant diffusion show that the partial diffusion data problem can be overcome with proper modeling and methods, and that hidden temporal characteristics of diffusion can be predicted from limited data.

  7. Single-photon emission computed tomography/computed tomography in lung cancer and malignant lymphoma.

    Science.gov (United States)

    Schillaci, Orazio

    2006-10-01

    In nuclear oncology, despite the fast-growing diffusion of (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET), single-photon emission computed tomography (SPECT) studies can still play an useful clinical role in several applications. The main limitation of SPECT imaging with tumor-seeking agents is the lack of the structural delineation of the pathologic processes they detect; this drawback sometimes renders SPECT interpretation difficult and can diminish its diagnostic accuracy. Fusion with morphological studies can overcome this limitation by giving an anatomical map to scintigraphic data. In the past, software-based fusion of independently performed SPECT and CT images proved to be time-consuming and impractical for routine use. The recent development of dual-modality integrated imaging systems that provide functional (SPECT) and anatomical (CT) images in the same scanning session, with the acquired images coregistered by means of the hardware, has opened a new era in this field. The first reports indicate that SPECT/CT is very useful in cancer imaging because it is able to provide further information of clinical value in several cases. In SPECT, studies of lung cancer and malignant lymphomas using different radiopharmaceutical, hybrid images are of value in providing the correct localization of tumor sites, with a precise detection of the involved organs, and the definition of their functional status, and in allowing the exclusion of disease in sites of physiologic tracer uptake. Therefore, in lung cancer and lymphomas, hybrid SPECT/CT can play a role in the diagnosis of the primary tumor, in the staging of the disease, in the follow-up, in the monitoring of therapy, in the detection of recurrence, and in dosimetric estimations for target radionuclide therapy.

  8. In-vivo dynamic characterization of microneedle skin penetration using optical coherence tomography

    Science.gov (United States)

    Enfield, Joey; O'Connell, Marie-Louise; Lawlor, Kate; Jonathan, Enock; O'Mahony, Conor; Leahy, Martin

    2010-07-01

    The use of microneedles as a method of circumventing the barrier properties of the stratum corneum is receiving much attention. Although skin disruption technologies and subsequent transdermal diffusion rates are being extensively studied, no accurate data on depth and closure kinetics of microneedle-induced skin pores are available, primarily due to the cumbersome techniques currently required for skin analysis. We report on the first use of optical coherence tomography technology to image microneedle penetration in real time and in vivo. We show that optical coherence tomography (OCT) can be used to painlessly measure stratum corneum and epidermis thickness, as well as microneedle penetration depth after microneedle insertion. Since OCT is a real-time, in-vivo, nondestructive technique, we also analyze skin healing characteristics and present quantitative data on micropore closure rate. Two locations (the volar forearm and dorsal aspect of the fingertip) have been assessed as suitable candidates for microneedle administration. The results illustrate the applicability of OCT analysis as a tool for microneedle-related skin characterization.

  9. Lymphocytic Thyroiditis Presenting as a Focal Uptake on 18F-Fluorodeoxyglucose Positron Emission Tomography: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Tae Seok; Kim, Eun Kyung; Lee, Sarah; Moon, Hee Jung; Kwak, Jin Young [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2011-12-15

    Diffuse increased uptake on 18F-Fluorodeoxyglucose Positron Emission Tomography (18F FDG PET) is a well-known finding of the lymphocytic thyroiditis. Nevertheless, a pathologic confirmation is needed in cases of a focal 18F FDG uptake in the thyroid gland. This article reports a rare case of a focal 18F FDG uptake lesion by PET, which was revealed pathologically to be lymphocytic thyroiditis

  10. Simultaneous whole body (18)F-fluorodeoxyglucose positron emission tomography magnetic resonance imaging for evaluation of pediatric cancer: Preliminary experience and comparison with (18)F-fluorodeoxyglucose positron emission tomography computed tomography.

    Science.gov (United States)

    Pugmire, Brian S; Guimaraes, Alexander R; Lim, Ruth; Friedmann, Alison M; Huang, Mary; Ebb, David; Weinstein, Howard; Catalano, Onofrio A; Mahmood, Umar; Catana, Ciprian; Gee, Michael S

    2016-03-28

    To describe our preliminary experience with simultaneous whole body (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography and magnetic resonance imaging (PET-MRI) in the evaluation of pediatric oncology patients. This prospective, observational, single-center study was Health Insurance Portability and Accountability Act-compliant, and institutional review board approved. To be eligible, a patient was required to: (1) have a known or suspected cancer diagnosis; (2) be under the care of a pediatric hematologist/oncologist; and (3) be scheduled for clinically indicated (18)F-FDG positron emission tomography-computed tomography (PET-CT) examination at our institution. Patients underwent PET-CT followed by PET-MRI on the same day. PET-CT examinations were performed using standard department protocols. PET-MRI studies were acquired with an integrated 3 Tesla PET-MRI scanner using whole body T1 Dixon, T2 HASTE, EPI diffusion-weighted imaging (DWI) and STIR sequences. No additional radiotracer was given for the PET-MRI examination. Both PET-CT and PET-MRI examinations were reviewed by consensus by two study personnel. Test performance characteristics of PET-MRI, for the detection of malignant lesions, including FDG maximum standardized uptake value (SUVmax) and minimum apparent diffusion coefficient (ADCmin), were calculated on a per lesion basis using PET-CT as a reference standard. A total of 10 whole body PET-MRI exams were performed in 7 pediatric oncology patients. The mean patient age was 16.1 years (range 12-19 years) including 6 males and 1 female. A total of 20 malignant and 21 benign lesions were identified on PET-CT. PET-MRI SUVmax had excellent correlation with PET-CT SUVmax for both benign and malignant lesions (R = 0.93). PET-MRI SUVmax > 2.5 had 100% accuracy for discriminating benign from malignant lesions using PET-CT reference. Whole body DWI was also evaluated: the mean ADCmin of malignant lesions (780.2 + 326.6) was significantly lower than

  11. Simultaneous whole body 18F-fluorodeoxyglucose positron emission tomography magnetic resonance imaging for evaluation of pediatric cancer: Preliminary experience and comparison with 18F-fluorodeoxyglucose positron emission tomography computed tomography

    Science.gov (United States)

    Pugmire, Brian S; Guimaraes, Alexander R; Lim, Ruth; Friedmann, Alison M; Huang, Mary; Ebb, David; Weinstein, Howard; Catalano, Onofrio A; Mahmood, Umar; Catana, Ciprian; Gee, Michael S

    2016-01-01

    AIM: To describe our preliminary experience with simultaneous whole body 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography and magnetic resonance imaging (PET-MRI) in the evaluation of pediatric oncology patients. METHODS: This prospective, observational, single-center study was Health Insurance Portability and Accountability Act-compliant, and institutional review board approved. To be eligible, a patient was required to: (1) have a known or suspected cancer diagnosis; (2) be under the care of a pediatric hematologist/oncologist; and (3) be scheduled for clinically indicated 18F-FDG positron emission tomography-computed tomography (PET-CT) examination at our institution. Patients underwent PET-CT followed by PET-MRI on the same day. PET-CT examinations were performed using standard department protocols. PET-MRI studies were acquired with an integrated 3 Tesla PET-MRI scanner using whole body T1 Dixon, T2 HASTE, EPI diffusion-weighted imaging (DWI) and STIR sequences. No additional radiotracer was given for the PET-MRI examination. Both PET-CT and PET-MRI examinations were reviewed by consensus by two study personnel. Test performance characteristics of PET-MRI, for the detection of malignant lesions, including FDG maximum standardized uptake value (SUVmax) and minimum apparent diffusion coefficient (ADCmin), were calculated on a per lesion basis using PET-CT as a reference standard. RESULTS: A total of 10 whole body PET-MRI exams were performed in 7 pediatric oncology patients. The mean patient age was 16.1 years (range 12-19 years) including 6 males and 1 female. A total of 20 malignant and 21 benign lesions were identified on PET-CT. PET-MRI SUVmax had excellent correlation with PET-CT SUVmax for both benign and malignant lesions (R = 0.93). PET-MRI SUVmax > 2.5 had 100% accuracy for discriminating benign from malignant lesions using PET-CT reference. Whole body DWI was also evaluated: the mean ADCmin of malignant lesions (780.2 + 326.6) was

  12. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  13. Comparison between conventional tomography and computer tomography in diseases of the sacroiliac joints

    International Nuclear Information System (INIS)

    Moritz, J.D.; Ganter, H.; Winter, C.; Evangelisches Krankenhaus, Giessen

    1990-01-01

    16 patients with diseases of the sacroiliac joints were examined both with computer tomography and with conventional tomography. Both techniques were characterized by a high sensitivity. Computer tomography was superior in exactly delineating the extent of the pathologic changes. In conventional tomography the joint surface was more blurred, erosions were larger, and signs of ankylosis were more expanded, so that the joints seemed to be more altered in 8 cases than demonstrated by computer tomography. Very accurate changes like subchondral cysts were recognized only in the computer tomograms. In all cases in which anteroposterior radiographs revealed no clear result, the authors recommend to additionally employ computer tomography. (orig.) [de

  14. A review of anisotropic conductivity models of brain white matter based on diffusion tensor imaging.

    Science.gov (United States)

    Wu, Zhanxiong; Liu, Yang; Hong, Ming; Yu, Xiaohui

    2018-06-01

    The conductivity of brain tissues is not only essential for electromagnetic source estimation (ESI), but also a key reflector of the brain functional changes. Different from the other brain tissues, the conductivity of whiter matter (WM) is highly anisotropic and a tensor is needed to describe it. The traditional electrical property imaging methods, such as electrical impedance tomography (EIT) and magnetic resonance electrical impedance tomography (MREIT), usually fail to image the anisotropic conductivity tensor of WM with high spatial resolution. The diffusion tensor imaging (DTI) is a newly developed technique that can fulfill this purpose. This paper reviews the existing anisotropic conductivity models of WM based on the DTI and discusses their advantages and disadvantages, as well as identifies opportunities for future research on this subject. It is crucial to obtain the linear conversion coefficient between the eigenvalues of anisotropic conductivity tensor and diffusion tensor, since they share the same eigenvectors. We conclude that the electrochemical model is suitable for ESI analysis because the conversion coefficient can be directly obtained from the concentration of ions in extracellular liquid and that the volume fraction model is appropriate to study the influence of WM structural changes on electrical conductivity. Graphical abstract ᅟ.

  15. Diffusing diffusivity: Rotational diffusion in two and three dimensions

    Science.gov (United States)

    Jain, Rohit; Sebastian, K. L.

    2017-06-01

    We consider the problem of calculating the probability distribution function (pdf) of angular displacement for rotational diffusion in a crowded, rearranging medium. We use the diffusing diffusivity model and following our previous work on translational diffusion [R. Jain and K. L. Sebastian, J. Phys. Chem. B 120, 3988 (2016)], we show that the problem can be reduced to that of calculating the survival probability of a particle undergoing Brownian motion, in the presence of a sink. We use the approach to calculate the pdf for the rotational motion in two and three dimensions. We also propose new dimensionless, time dependent parameters, αr o t ,2 D and αr o t ,3 D, which can be used to analyze the experimental/simulation data to find the extent of deviation from the normal behavior, i.e., constant diffusivity, and obtain explicit analytical expressions for them, within our model.

  16. Diffusion-weighted MR-imaging for the detection of pulmonary nodules at 1.5 Tesla: intraindividual comparison with multidetector computed tomography

    International Nuclear Information System (INIS)

    Regier, Marc; Schwarz, Dorothee; Henes, Frank Oliver; Groth, Michael; Begemann, Philipp G.C.; Adam, Gerhard; Kooijman, Hendrik

    2011-01-01

    To investigate the feasibility of diffusion-weighted imaging (DWI) MRI for detecting pulmonary nodules at 1.5 Tesla in comparison with standard multidetector computed tomography (MDCT). Twenty patients with disseminated cancer disease in which MDCT had assured the presence of at least one pulmonary nodule were examined using a respiratory-gated DWI MR-sequence. Grey scale inverted source images and coronal maximum intensity projection (MIP) images were consensually analysed by two experienced radiologists. Size and location of any nodule detected were assessed. Additionally, the readers evaluated each hemithorax for the presence of at least one nodule and applied a four-point conspicuity scale (1-hemithorax definitely affected; 4-hemithorax definitely not affected). MDCT data served as reference. At MDCT, a total of 71 pulmonary noduIes was found (size 3–5 mm, n = 16; 6–9 mm, n = 22; ≥10 mm, n = 33). For the DWI MR-sequence, a sensitivity of 86.4% was calculated for nodules ranging 6–9 mm and 97% for nodules ≥10 mm. In contrast, only 43.8% of lesions ≤5 mm was detected. The separate analysis of each hemithorax for the presence of at least one pulmonary nodule revealed a specificity rate, PPV and NPV of DWI-MR of 92.3%, 96% and 80%, respectively. The presented study is the first to confirm the diagnostic potential of DWI-MR in the detection of solid lung nodules. This technique allows for the detection of nodules ≥6 mm with reasonably high sensitivity rates (>86%). The observation of false positive findings decreases the accuracy of this approach compared with MDCT.

  17. Quantitative imaging of cerebral blood flow velocity and intracellular motility using dynamic light scattering-optical coherence tomography.

    Science.gov (United States)

    Lee, Jonghwan; Radhakrishnan, Harsha; Wu, Weicheng; Daneshmand, Ali; Climov, Mihail; Ayata, Cenk; Boas, David A

    2013-06-01

    This paper describes a novel optical method for label-free quantitative imaging of cerebral blood flow (CBF) and intracellular motility (IM) in the rodent cerebral cortex. This method is based on a technique that integrates dynamic light scattering (DLS) and optical coherence tomography (OCT), named DLS-OCT. The technique measures both the axial and transverse velocities of CBF, whereas conventional Doppler OCT measures only the axial one. In addition, the technique produces a three-dimensional map of the diffusion coefficient quantifying nontranslational motions. In the DLS-OCT diffusion map, we observed high-diffusion spots, whose locations highly correspond to neuronal cell bodies and whose diffusion coefficient agreed with that of the motion of intracellular organelles reported in vitro in the literature. Therefore, the present method has enabled, for the first time to our knowledge, label-free imaging of the diffusion-like motion of intracellular organelles in vivo. As an example application, we used the method to monitor CBF and IM during a brief ischemic stroke, where we observed an induced persistent reduction in IM despite the recovery of CBF after stroke. This result supports that the IM measured in this study represent the cellular energy metabolism-related active motion of intracellular organelles rather than free diffusion of intracellular macromolecules.

  18. Pleural localized malignant mesothelioma mimicking a benign solitary fibrous tumor of the pleura on chest computed tomography: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hwi Ryong; Chong, Se Min; Kim, Mi Kyung [Dept. of Radiology, (Korea, Republic of)

    2017-06-15

    Pleural malignant mesotheliomas arise from mesothelial cells in the pleura. They are characterized as diffuse or localized malignant mesotheliomas (LMM). Diffuse malignant mesotheliomas spread diffusely along pleural surfaces, while LMM are well-circumscribed nodular lesions with no gross or microscopic diffuse pleural spreading. Therefore, LMM can be radiologically confused with solitary fibrous tumors of the pleura (SFTP), which commonly presents as a solitary, well-demarcated peripheral mass abutting the pleural surface upon the completion of a computed tomography (CT). Therefore, this study reports on a 63-year-old female patient with a pathologically-proven LMM of the pleura, mimicking a benign SFTP upon having a chest CT. Although LMM is extremely rare, FDG PET/CT should be recommended for adequate tumor management in order to avoid misdiagnosing the tumor as a benign SFTP when an interfissural or pleural-based mass is seen on the chest CT.

  19. Pleural localized malignant mesothelioma mimicking a benign solitary fibrous tumor of the pleura on chest computed tomography: A case report

    International Nuclear Information System (INIS)

    Park, Hwi Ryong; Chong, Se Min; Kim, Mi Kyung

    2017-01-01

    Pleural malignant mesotheliomas arise from mesothelial cells in the pleura. They are characterized as diffuse or localized malignant mesotheliomas (LMM). Diffuse malignant mesotheliomas spread diffusely along pleural surfaces, while LMM are well-circumscribed nodular lesions with no gross or microscopic diffuse pleural spreading. Therefore, LMM can be radiologically confused with solitary fibrous tumors of the pleura (SFTP), which commonly presents as a solitary, well-demarcated peripheral mass abutting the pleural surface upon the completion of a computed tomography (CT). Therefore, this study reports on a 63-year-old female patient with a pathologically-proven LMM of the pleura, mimicking a benign SFTP upon having a chest CT. Although LMM is extremely rare, FDG PET/CT should be recommended for adequate tumor management in order to avoid misdiagnosing the tumor as a benign SFTP when an interfissural or pleural-based mass is seen on the chest CT

  20. The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in resectable pancreatic cancer.

    Science.gov (United States)

    Crippa, Stefano; Salgarello, Matteo; Laiti, Silvia; Partelli, Stefano; Castelli, Paola; Spinelli, Antonello E; Tamburrino, Domenico; Zamboni, Giuseppe; Falconi, Massimo

    2014-08-01

    The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in pancreatic ductal adenocarcinoma is debated. We retrospectively assessed the value of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in addition to conventional imaging as a staging modality in pancreatic cancer. (18)Fluoro-deoxyglucose positron emission tomography/computed tomography was performed in 72 patients with resectable pancreatic carcinoma after multi-detector computed tomography positron emission tomography was considered positive for a maximum standardized uptake value >3. Overall, 21% of patients had a maximum standardized uptake value ≤ 3, and 60% of those had undergone neoadjuvant treatment (P=0.0001). Furthermore, 11% of patients were spared unwarranted surgery since positron emission tomography/computed tomography detected metastatic disease. All liver metastases were subsequently identified with contrast-enhanced ultrasound. Sensitivity and specificity of positron emission tomography/computed tomography for distant metastases were 78% and 100%. The median CA19.9 concentration was 48.8 U/mL for the entire cohort and 292 U/mL for metastatic patients (P=0.112). The widespread application of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in patients with resectable pancreatic carcinoma seems not justified. It should be considered in selected patients at higher risk of metastatic disease (i.e. CA19.9>200 U/mL) after undergoing other imaging tests. Neoadjuvant treatment is significantly associated with low metabolic activity, limiting the value of positron emission tomography in this setting. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  1. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  2. Radiological features of subependymoma with emphasis on computed tomography

    International Nuclear Information System (INIS)

    Stevens, J.M.; Kendall, B.E.; Love, S.

    1984-01-01

    The features of 17 symptomatic subependymomas on X-ray computed tomography are described. Thirteen were reviewed from isolated case reports and 4 were original material. Over half were entirely intraventricular, 6 extended into brain substance and 2 into subarachnoidal cisterns. Twelve were isodense, 15 showed diffuse but irregular enhancement, and 5 contained nodular calcification. Large low density cysts, intratumoural haemorrhage and brain oedema were found almost exclusively in lesions extending into brain substance. It is concluded that subependymomas resemble ependymomas too closely on CT to be distinguished radiographically from them as a separate group. However subependymomas contain calcification slightly less frequently, and usually appear as mainly intraventicular lesions even when they occur above the tentorium. (orig.)

  3. Computerized axial tomography in the detection of brain damage

    International Nuclear Information System (INIS)

    Cala, L.A.; Mastaglia, F.L.

    1980-01-01

    The cranial computerized axial tomography (CAT) findings in groups of patients with epilepsy, migraine, hypertension, and other general medical disorders have been reviewed to assess the frequency and patterns of focal and diffuse brain damage. In addition to demonstrating focal lesions in a proportion of patients with seizures and in patients presenting with a stroke, the CAT scan showed a premature degree of cerebral atrophy in an appreciable proportion of patients with long-standing epilepsy, hypertension and diabetes, and in some patients with migraine, valvular and ischaemic heart disease, chronic obstructive airways disease, and chronic renal failure. The value of CAT as a means of screening for brain damage in groups of individuals at risk is discussed

  4. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  5. Review of muon tomography

    International Nuclear Information System (INIS)

    Feng Hanliang; Jiao Xiaojing

    2010-01-01

    As a new detection technology, Muon tomography has some potential benefits, such as being able to form a three- dimensional image, without radiation, low cost, fast detecting etc. Especially, muon tomography will play an important role in detecting nuclear materials. It introduces the theory of Muon tomography, its advantages and the Muon tomography system developed by decision sciences corporation and Los Alamos national laboratory. (authors)

  6. Borehole radar diffraction tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seong Jun; Kim, Jung Ho; Yi, Myeong Jong; Chung, Seung Hwan; Lee, Hee Il [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1997-12-01

    Tomography is widely used as imaging method for determining subsurface structure. Among the reconstruction algorithms for tomographic imaging, travel time tomography is almost applied to imaging subsurface. But isolated small body comparable with the wavelength could not be well recognized by travel time tomography. Other tomographic method are need to improve the imaging process. In the study of this year, diffraction tomography was investigated. The theory for diffraction tomography is based on the 1st-order Born approximation. Multisource holography, which is similar to Kirchihoff migration, is compared with diffraction tomography. To improve 1st-order Born diffraction tomography, two kinds of filter designed from multisource holography and 2-D green function, respectively, applied on the reconstructed image. The algorithm was tested for the numerical modeling data of which algorithm consists of the analytic computation of radar signal in transmitter and receiver regions and 2-D FDM scheme for the propagation of electromagnetic waves in media. The air-filled cavity model to show a typical diffraction pattern was applied to diffraction tomography imaging, and the result shows accurate location and area of cavity. But the calculated object function is not well matched the real object function, because the air-filled cavity model is not satisfied week scattered inhomogeneity for 1st born approximation, and the error term is included in estimating source wavelet from received signals. In spite of the object function error, the diffraction tomography assist for interpretation of subsurface as if conducted with travel time tomography. And the fracture model was tested, 1st born diffraction tomographic image is poor because of limited view angle coverage and violation of week scatter assumption, but the filtered image resolve the fracture somewhat better. The tested diffraction tomography image confirms effectiveness of filter for enhancing resolution. (author). 14

  7. Localization of alpha emitters by damage production in a thin film. Application to the study of alpha emitter diffusion in irradiated samples; Localisation des emetteurs alpha par creation de dommages dans un film mince. Application a l'etude de la diffusion des emetteurs alpha dans des echantillons irradies

    Energy Technology Data Exchange (ETDEWEB)

    Houdaille, B; Perrot, M [Commissariat a l' Energie Atomique, 91 - Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    The process of recording {alpha} particles on cellulose nitrate films, called alpha-graphy, is applied to the study of the diffusion of {alpha}-emitting elements in irradiated alloys. The existence of diffusion is shown by attacking the film with concentrated caustic soda after exposition. The insensitivity of the recorder to {beta} {gamma} radiation emitted by the sample after passing in the reactor makes it possible to operate with long exposure times and to detect small diffusions. The concentration-penetration curves are drawn up after carrying out a densitometric analysis of the alpha-graphies. - As the cellulose nitrate is affected only by {alpha} particles of energies of between 0.5 and 4 MeV, it was first necessary to determine the yield of the recorder for {alpha} particles emitted by a thick source, i.e. whose energy varies between 0 and E{sub 0}, E{sub 0} being the energy of the alpha emitter. - The concentration C of the {alpha}-emitter, as a function of the optical density D of the alpha-graphy, and of the exposure time t is given by a simple relationship: C = D/at where a is an experimental constant determined by calibration. It depends on the nature of the cellulose nitrate, of the {alpha}-emitting element and of the alloy studied. (authors) [French] Le procede d'enregistrement des particules alpha sur film de nitrate de cellulose, ou alphagraphie, est applique a l'etude de la diffusion d'elements emetteurs alpha dans des alliages irradies. La diffusion est mise en evidence par une attaque du film de nitrate, apres exposition, dans de la soude concentree. L'insensibilite de l'enregistreur au rayonnement {beta} {gamma}, emis par l'echantillon apres son sejour en pile, permet d'operer sur de longs temps de pose et de detecter des diffusions faibles. Les courbes concentration - penetration sont etablies par exploitation densitometrique des alphagraphies. - Comme le nitrate de cellulose n'est impressionne que par des particules alpha dont l'energie est

  8. Diffuse Subcutaneous Emphysema and Pneumomediastinum Secondary to a Minor Blunt Chest Trauma

    Directory of Open Access Journals (Sweden)

    Maximilian Andreas Storz

    2017-01-01

    Full Text Available Full medical evaluation is paramount for all trauma patients. Minor traumas are often overlooked, as they are thought to bear low injury potential. In this case report, we describe the case of a 48-year-old man presenting to our Emergency Department with mild to moderate right-sided shoulder and scapular pain following a fall from his own height ten days previously. Clinical and paraclinical investigations (CT revealed diffuse right shoulder pain, with crepitations on palpation of the neck, right shoulder, and right lateral chest wall. Computed tomography (CT demonstrated right-sided costal fractures (ribs 7 to 9, with diffuse subcutaneous emphysema and pneumomediastinum due to laceration of the visceral and parietal pleura and the adjacent lung parenchyma. In addition, a small ipsilateral pneumothorax was found. Surprisingly, the clinical status was only minimally affected by mild to moderate pain and minor functional impairment.

  9. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  10. Spatio-temporal diffusion of dynamic PET images

    International Nuclear Information System (INIS)

    Tauber, C; Chalon, S; Guilloteau, D; Stute, S; Buvat, I; Chau, M; Spiteri, P

    2011-01-01

    Positron emission tomography (PET) images are corrupted by noise. This is especially true in dynamic PET imaging where short frames are required to capture the peak of activity concentration after the radiotracer injection. High noise results in a possible bias in quantification, as the compartmental models used to estimate the kinetic parameters are sensitive to noise. This paper describes a new post-reconstruction filter to increase the signal-to-noise ratio in dynamic PET imaging. It consists in a spatio-temporal robust diffusion of the 4D image based on the time activity curve (TAC) in each voxel. It reduces the noise in homogeneous areas while preserving the distinct kinetics in regions of interest corresponding to different underlying physiological processes. Neither anatomical priors nor the kinetic model are required. We propose an automatic selection of the scale parameter involved in the diffusion process based on a robust statistical analysis of the distances between TACs. The method is evaluated using Monte Carlo simulations of brain activity distributions. We demonstrate the usefulness of the method and its superior performance over two other post-reconstruction spatial and temporal filters. Our simulations suggest that the proposed method can be used to significantly increase the signal-to-noise ratio in dynamic PET imaging.

  11. Multi-scale structural analysis of gas diffusion layers

    Science.gov (United States)

    Göbel, Martin; Godehardt, Michael; Schladitz, Katja

    2017-07-01

    The macroscopic properties of materials are strongly determined by their micro structure. Here, transport properties of gas diffusion layers (GDL) for fuel cells are considered. In order to simulate flow and thermal properties, detailed micro structural information is essential. 3D images obtained by high-resolution computed tomography using synchrotron radiation and scanning electron microscopy (SEM) combined with focused ion beam (FIB) serial slicing were used. A recent method for reconstruction of porous structures from FIB-SEM images and sophisticated morphological image transformations were applied to segment the solid structural components. The essential algorithmic steps for segmenting the different components in the tomographic data-sets are described and discussed. In this paper, two types of GDL, based on a non-woven substrate layer and a paper substrate layer were considered, respectively. More than three components are separated within the synchrotron radiation computed tomography data. That is, fiber system, polytetrafluoroethylene (PTFE) binder/impregnation, micro porous layer (MPL), inclusions within the latter, and pore space are segmented. The usage of the thus derived 3D structure data in different simulation applications can be demonstrated. Simulations of macroscopic properties such as thermal conductivity, depending on the flooding state of the GDL are possible.

  12. Giant cavernous hemangioma coexistent with diffuse hepatic hemangiomatosis presenting as portal vein thrombosis and hepatic lobar atrophy

    Directory of Open Access Journals (Sweden)

    Bo Reum Yoo

    2014-01-01

    Full Text Available

    A combination of giant hepatic hemangioma and diffuse hemangiomatosis is extremely rare in adults. Even when they are large, hemangiomas are soft and rarely compress adjacent structures. A 78-year-old man presented with abdominal pain and distension. Ultrasonography, computed tomography, and magnetic resonance imaging demonstrated a large expansile mass replacing the medial segment and caudate lobe with diffusely scattered nodules in the entire liver. The large hilar mass contained a central nonenhancing area and had a mass effect, leading to left portal vein occlusion. The image findings also revealed two unprecedented findings: left lateral segmental atrophy of the liver and recent portomesenteric vein thrombosis. The hepatic lesions were confirmed with hemangiomas by ultrasonography-guided biopsy. We diagnosed intrahepatic portal vein obstruction caused by a mass effect of giant hepatic hemangioma coexistent with diffuse hemangiomatosis, resulting in hepatic segmental atrophy and extrahepatic portal vein thrombosis.

  13. Giant cavernous hemangioma coexistent with diffuse hepatic hemangiomatosis presenting as portal vein thrombosis and hepatic lobar atrophy

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Bo Reum; Han, Hyun Young; Choi, So Young; Kim, Joo Heun [Eulji University Hospital, Daejeon(Korea, Republic of)

    2014-03-15

    A combination of giant hepatic hemangioma and diffuse hemangiomatosis is extremely rare in adults. Even when they are large, hemangiomas are soft and rarely compress adjacent structures. A 78-year-old man presented with abdominal pain and distension. Ultrasonography, computed tomography, and magnetic resonance imaging demonstrated a large expansile mass replacing the medial segment and caudate lobe with diffusely scattered nodules in the entire liver. The large hilar mass contained a central nonenhancing area and had a mass effect, leading to left portal vein occlusion. The image findings also revealed two unprecedented findings: left lateral segmental atrophy of the liver and recent portomesenteric vein thrombosis. The hepatic lesions were confirmed with hemangiomas by ultrasonography-guided biopsy. We diagnosed intrahepatic portal vein obstruction caused by a mass effect of giant hepatic hemangioma coexistent with diffuse hemangiomatosis, resulting in hepatic segmental atrophy and extrahepatic portal vein thrombosis.

  14. Diffusion-weighted imaging for the follow-up of patients after matrix-associated autologous chondrocyte transplantation

    International Nuclear Information System (INIS)

    Friedrich, Klaus M.; Mamisch, Tallal C.; Plank, Christina; Langs, Georg; Marlovits, Stefan; Salomonowitz, Erich; Trattnig, Siegfried; Welsch, Goetz

    2010-01-01

    Objective: To evaluate the use of diffusion-weighted imaging (DWI) for the assessment of cartilage maturation in patients after matrix-associated autologous chondrocyte transplantation (MACT). Materials and methods: Fifteen patients after MACT were examined by 3.0-T magnetic-resonance-tomography; the examination was up to 13 month after surgery in group 1, and later than 13 month after surgery in group 2. Both groups had a follow-up one-year later. DWI was acquired using a steady-state gradient-echo sequence. Mean values of the diffusion quotients of regions of interest within cartilage repair tissue and of reference regions were assessed. Each region-of-interest was subdivided into a deep, and a superficial area. Results: Mean diffusion quotients of cartilage repair tissues were 1.44 (baseline), and 1.44 (follow-up). Mean diffusion quotients of reference tissues were 1.29 (baseline) and 1.28 (follow-up). At the follow-up diffusion quotients of cartilage repair tissue were significantly higher than those of reference cartilage. In group 1 the diffusion quotients were significantly lower at the follow-up (1.45 versus 1.65); in group 2 no statistically significant differences between follow-up (1.39) and baseline (1.41) were found. Reference cartilages and cartilage repair tissues of group 2 showed a decrease of diffusion quotients from the deep to the superficial area being stable at the follow-up. In group 1 initially a significant increase (1.49 versus 1.78) of the diffusion quotients from deep to superficial area of the cartilage repair tissue was found changing into a decrease (1.65 versus 1.52) at the follow-up. Conclusions: DWI detected changes of diffusion within cartilage repair tissue that may reflect cartilage maturation. Changes in diffusity occurred up to two years after surgery and were stable later. Zonal variations within cartilage could be measured.

  15. High resolution computed tomography in patients with various forms of systemic sclerosis

    International Nuclear Information System (INIS)

    Lewszuk, A.; Rozycki, J.; Tarasow, E.; Kowal-Bielecka, O.

    2008-01-01

    Pulmonary lesions are, besides renal and cardiac complications, one of the main causes of mortality among patients with systemic sclerosis (scleroderma). Pathologic changes in the respiratory system take the form of interstitial fibrosis clinically manifested by progressive exertion dyspnea and abnormalities of respiratory restriction type in functional tests. The aim of the study was systematization of pulmonary lesion symptomatology in conventional chest radiography and high resolution computed tomography (HRCT) in patients with various forms of scleroderma, as well as determination of the frequency and localization of the particular lesion types. The study was carried out in a group of 49 patients with systemic sclerosis (47 women and 2 men), who underwent conventional radiography and high resolution computed tomography of the chest. In patients with systemic sclerosis, HRCT revealed most frequently interstitial changes of ground glass type, as well as linear and reticular opacities, whereas bronchiectasis and honeycombing type lesions were less frequent. Pulmonary lesions were seen with increasing frequency towards the lung base and were localized mainly in the posterior, inferior and peripheral parts of the lungs. Comparison of the patients with limited and diffuse scleroderma demonstrated that the diffuse form is associated with more frequent involvement of the respiratory system and more advanced pulmonary lesions. The observed characteristics of pulmonary lesions show similarity between interstitial lung disease in the course of systemic sclerosis and nonspecific interstitial pneumonia (NSIP), which supports classification of interstitial lung disease associated with scleroderma as belonging to that group of interstitial inflammations. (author)

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  17. Research on the structure in solution of optically active synthetic polymers (propylene polysulphide, propylene polyoxide, tertio-butyl polysulphide); Recherche de la structure en solution de polymeres synthetiques, optiquement actifs (polysulfure de propylene, polyoxyde de propylene, polysulfure de tertiobutyle)

    Energy Technology Data Exchange (ETDEWEB)

    Sarrazin, Brigitte

    1971-03-15

    It was proposed to study the structure of sulphur-containing synthetic polymers, stereo-regular, optically active in solution and able to adopt a spiral conformation, with special reference to propylene polysulphide. Two methods were used, the first mathematical (conformational energy calculations) and the second physico-chemical, essentially spectroscopic. By conformational analysis it is possible to choose the most probable structures liable to be adopted by a given polymer in solution while the spectro-polarimetric study should, in principle, invalidate or confirm certain of these hypotheses. The conformational energy calculations showed that in fact there is no energy conformation low enough to be stable in solution. Strictly speaking however we can refer to a region of stability in which steric hindrance is low and many energy minima exist. These minima are indistinguishable both by their energy values and by their spatial localizations and are all enclosed in the region bounded by the barriers due to steric hindrance. This uncertainty does not arise from approximations made in the calculations, but from the multitude of stereochemical structure possible. Investigations into the variation of the optical rotary dispersion and the circular dichroism as a function of temperature indicated the existence of three or more equilibrium states in the dioxane. The spectra appear to be the summation of the optical activities of the numerous simultaneously possible conformations. It appears that polymers, such as propylene polysulphide or propylene polyoxide do not have stable structures in solution. These are molecules of great flexibility possessing a large number of degrees of freedom. These properties distinguish them from the natural polymers, carrying precise information, such as DNA which must consequently have stable conformations. (author) [French] On s'est propose d'etudier la structure de polymeres synthetiques soufres, stereoreguliers, optiquement actifs en

  18. Diffuse axonal injury: detection of changes in anisotropy of water diffusion by diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Chan, J.H.M.; Tsui, E.Y.K.; Yuen, M.K.; Peh, W.C.G.; Fong, D.; Fok, K.F.; Leung, K.M.; Fung, K.K.L.

    2003-01-01

    Myelinated axons of white matter demonstrate prominent directional differences in water diffusion. We performed diffusion-weighted imaging on ten patients with head injury to explore the feasibility of using water diffusion anisotropy for quantitating diffuse axonal injury. We showed significant decrease in diffusion anisotropy indices in areas with or without signal abnormality on T2 and T2*-weighted images. We conclude that the water diffusion anisotropy index a potentially useful, sensitive and quantitative way of diagnosing and assessing patients with diffuse axonal injury. (orig.)

  19. Quantitative photo-acoustic tomography with partial data

    International Nuclear Information System (INIS)

    Chen, Jie; Yang, Yang

    2012-01-01

    Photo-acoustic tomography is a newly developed hybrid imaging modality that combines a high-resolution modality with a high-contrast modality. We analyze the reconstruction of diffusion and absorption parameters in an elliptic equation and extend an earlier result of Bal and Uhlmann (2010 Inverse Problems 26 085010) to the partial data case. We show that the reconstruction can be uniquely determined by the knowledge of four internal data based on well-chosen partial boundary conditions. Stability of this reconstruction is ensured if a convexity condition is satisfied. A similar stability result is obtained without this geometric constraint if 4n well chosen partial boundary conditions are available, where n is the spatial dimension. The set of well chosen boundary measurements is characterized by some complex geometric optics solutions vanishing on a part of the boundary. (paper)

  20. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  1. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    Energy Technology Data Exchange (ETDEWEB)

    Tamaki, S; Kadota, K; Kambara, H; Suzuki, Y; Nohara, R; Murakami, T; Kawai, C; Tamaki, N; Torizuka, K [Kyoto Univ. (Japan). Faculty of Medicine

    1984-07-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man.

  2. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    International Nuclear Information System (INIS)

    Tamaki, S.; Kadota, K.; Kambara, H.; Suzuki, Y.; Nohara, R.; Murakami, T.; Kawai, C.; Tamaki, N.; Torizuka, K.

    1984-01-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man. (author)

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  5. Spin-diffusions and diffusive molecular dynamics

    Science.gov (United States)

    Farmer, Brittan; Luskin, Mitchell; Plecháč, Petr; Simpson, Gideon

    2017-12-01

    Metastable configurations in condensed matter typically fluctuate about local energy minima at the femtosecond time scale before transitioning between local minima after nanoseconds or microseconds. This vast scale separation limits the applicability of classical molecular dynamics (MD) methods and has spurned the development of a host of approximate algorithms. One recently proposed method is diffusive MD which aims at integrating a system of ordinary differential equations describing the likelihood of occupancy by one of two species, in the case of a binary alloy, while quasistatically evolving the locations of the atoms. While diffusive MD has shown itself to be efficient and provide agreement with observations, it is fundamentally a model, with unclear connections to classical MD. In this work, we formulate a spin-diffusion stochastic process and show how it can be connected to diffusive MD. The spin-diffusion model couples a classical overdamped Langevin equation to a kinetic Monte Carlo model for exchange amongst the species of a binary alloy. Under suitable assumptions and approximations, spin-diffusion can be shown to lead to diffusive MD type models. The key assumptions and approximations include a well-defined time scale separation, a choice of spin-exchange rates, a low temperature approximation, and a mean field type approximation. We derive several models from different assumptions and show their relationship to diffusive MD. Differences and similarities amongst the models are explored in a simple test problem.

  6. Monitoring of human brain functions in risk decision-making task by diffuse optical tomography using voxel-wise general linear model

    Science.gov (United States)

    Lin, Zi-Jing; Li, Lin; Cazzell, Marry; Liu, Hanli

    2013-03-01

    Functional near-infrared spectroscopy (fNIRS) is a non-invasive imaging technique which measures the hemodynamic changes that reflect the brain activity. Diffuse optical tomography (DOT), a variant of fNIRS with multi-channel NIRS measurements, has demonstrated capability of three dimensional (3D) reconstructions of hemodynamic changes due to the brain activity. Conventional method of DOT image analysis to define the brain activation is based upon the paired t-test between two different states, such as resting-state versus task-state. However, it has limitation because the selection of activation and post-activation period is relatively subjective. General linear model (GLM) based analysis can overcome this limitation. In this study, we combine the 3D DOT image reconstruction with GLM-based analysis (i.e., voxel-wise GLM analysis) to investigate the brain activity that is associated with the risk-decision making process. Risk decision-making is an important cognitive process and thus is an essential topic in the field of neuroscience. The balloon analogue risk task (BART) is a valid experimental model and has been commonly used in behavioral measures to assess human risk taking action and tendency while facing risks. We have utilized the BART paradigm with a blocked design to investigate brain activations in the prefrontal and frontal cortical areas during decision-making. Voxel-wise GLM analysis was performed on 18human participants (10 males and 8females).In this work, we wish to demonstrate the feasibility of using voxel-wise GLM analysis to image and study cognitive functions in response to risk decision making by DOT. Results have shown significant changes in the dorsal lateral prefrontal cortex (DLPFC) during the active choice mode and a different hemodynamic pattern between genders, which are in good agreements with published literatures in functional magnetic resonance imaging (fMRI) and fNIRS studies.

  7. Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography and (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for recurrent prostate carcinoma: results of a prospective clinical trial.

    Science.gov (United States)

    Schuster, David M; Nieh, Peter T; Jani, Ashesh B; Amzat, Rianot; Bowman, F Dubois; Halkar, Raghuveer K; Master, Viraj A; Nye, Jonathon A; Odewole, Oluwaseun A; Osunkoya, Adeboye O; Savir-Baruch, Bital; Alaei-Taleghani, Pooneh; Goodman, Mark M

    2014-05-01

    We prospectively evaluated the amino acid analogue positron emission tomography radiotracer anti-3-[(18)F]FACBC compared to ProstaScint® ((111)In-capromab pendetide) single photon emission computerized tomography-computerized tomography to detect recurrent prostate carcinoma. A total of 93 patients met study inclusion criteria who underwent anti-3-[(18)F]FACBC positron emission tomography-computerized tomography plus (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for suspected recurrent prostate carcinoma within 90 days. Reference standards were applied by a multidisciplinary board. We calculated diagnostic performance for detecting disease. In the 91 of 93 patients with sufficient data for a consensus on the presence or absence of prostate/bed disease anti-3-[(18)F]FACBC had 90.2% sensitivity, 40.0% specificity, 73.6% accuracy, 75.3% positive predictive value and 66.7% negative predictive value compared to (111)In-capromab pendetide with 67.2%, 56.7%, 63.7%, 75.9% and 45.9%, respectively. In the 70 of 93 patients with a consensus on the presence or absence of extraprostatic disease anti-3-[(18)F]FACBC had 55.0% sensitivity, 96.7% specificity, 72.9% accuracy, 95.7% positive predictive value and 61.7% negative predictive value compared to (111)In-capromab pendetide with 10.0%, 86.7%, 42.9%, 50.0% and 41.9%, respectively. Of 77 index lesions used to prove positivity histological proof was obtained in 74 (96.1%). Anti-3-[(18)F]FACBC identified 14 more positive prostate bed recurrences (55 vs 41) and 18 more patients with extraprostatic involvement (22 vs 4). Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography correctly up-staged 18 of 70 cases (25.7%) in which there was a consensus on the presence or absence of extraprostatic involvement. Better diagnostic performance was noted for anti-3-[(18)F]FACBC positron emission tomography-computerized tomography than for (111)In-capromab pendetide single

  8. Unmasking the mechanism of diffuse left ventricular wall motion abnormality in ischemic cardiomyopathy by resting-redistribution thallium-201 single photon computed tomography

    International Nuclear Information System (INIS)

    Namura, Hiroyuki; Yamabe, Hiroshi; Kakimoto, Tetsuya; Hashimoto, Yasunori; Yasaka, Yoshinori; Yoshida, Hiroaki; Itoh, Kazushi; Yokoyama, Mitsuhiro; Maeda, Kazumi.

    1992-01-01

    The study population comprised patients with ischemic cardiomyopathy (ICM) who had left ventricular wall motion (LVWM) abnormality in 5 or more segments (n=9), those with extensive myocardial infarction (EMI) having LVWM abnormality in 4 or less segments (n=12), and those with dilated left ventricle (DLV) having LVWM abnormality in all 7 segments (n=9). Defect scores (DS), obtained by initial and delayed Tl-201 myocardial single photon emission computed tomography at rest, were visually assessed to compare perfusion patterns in the three patient groups. The group of ICM patients had greater defect segments (DSeg) and % redistribution (Rd) index than the other two groups, although there was no difference in the number of angiographically proven infarct-related coronary vessels between EMI and ICM. In the group of ICM patients, there was inverse correlation not only between left ventricular ejection fraction and the sum of DS but also between left ventricular enddiastolic volume index and both the sum of DSeg and % Rd index. The group of DLV patients had small sum of DSeg and redistribution, compared with the other two groups. Although diffuse LVWM abnormality, as observed in the group of ICM patients, was considered attributable to potential decrease of coronary perfusion shown as defect on SPECT images, it did not always coincide with findings of coronary angiography. Both DSeg and redistribution phenomenon on SPECT images seemed to have the ability to evaluate the severity of ICM, as well as to differentiate ICM, EMI, and DLV. (N.K.)

  9. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  10. Simulation of diffusion-induced stress using reconstructed electrodes particle structures generated by micro/nano-CT

    International Nuclear Information System (INIS)

    Lim, Cheolwoong; Yan Bo; Yin Leilei; Zhu Likun

    2012-01-01

    Highlights: ► The microstructure of LIB electrodes was obtained by X-ray micro/nano-CT. ► We studied diffusion-induced stresses based on realistic 3D microstructures. ► Stresses depend on geometric characteristics of electrode particle. ► Stresses in a real particle are much higher than those in a spherical particle. - Abstract: Lithium ion batteries experience diffusion-induced stresses during charge and discharge processes which can cause electrode failure in the form of fracture. Previous diffusion-induced stress models and simulations are mainly based on simple active material particle structures, such as spheres and ellipsoids. However, the simple structure model cannot reveal the stress development in a real complex lithium ion battery electrode. In this paper, we studied the diffusion-induced stresses numerically based on a realistic morphology of reconstructed particles during the lithium ion intercalation process. The morphology of negative and positive active materials of a lithium ion battery was determined using X-ray micro/nano computed tomography technology. Diffusion-induced stresses were simulated at different C rates under galvonostatic conditions and compared with spherical particles. The simulation results show that the intercalation stresses of particles depend on their geometric characteristics. The highest von Mises stress and Tresca stress in a real particle are several times higher than the stresses in a spherical particle with the same volume.

  11. Single photon emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-09-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) imaging technique. Content: 1 - Introduction: anatomic, functional and molecular imaging; Principle and role of functional or molecular imaging; 2 - Radiotracers: chemical and physical constraints, main emitters, radioisotopes production, emitters type and imaging techniques; 3 - Single photon emission computed tomography: gamma cameras and their components, gamma camera specifications, planar single photon imaging characteristics, gamma camera and tomography; 4 - Quantification in single photon emission tomography: attenuation, scattering, un-stationary spatial resolution, partial volume effect, movements, others; 5 - Synthesis and conclusion

  12. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  13. SU-E-I-52: Validation of Multi-Frequency Electrical Impedance Tomography Using Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kohli, K; Liu, F; Krishnan, K [BC Cancer Agency, Surrey, BC (United Kingdom)

    2014-06-01

    Purpose: Multi-frequency EIT has been reported to be a potential tool in distinguishing a tissue anomaly from background. In this study, we investigate the feasibility of acquiring functional information by comparing multi-frequency EIT images in reference to the structural information from the CT image through fusion. Methods: EIT data was acquired from a slice of winter melon using sixteen electrodes around the phantom, injecting a current of 0.4mA at 100, 66, 24.8 and 9.9 kHz. Differential EIT images were generated by considering different combinations of pair frequencies, one serving as reference data and the other as test data. The experiment was repeated after creating an anomaly in the form of an off-centered cavity of diameter 4.5 cm inside the melon. All EIT images were reconstructed using Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software (EIDORS) package in 2-D differential imaging mode using one-step Gaussian Newton minimization solver. CT image of the melon was obtained using a Phillips CT Scanner. A segmented binary mask image was generated based on the reference electrode position and the CT image to define the regions of interest. The region selected by the user was fused with the CT image through logical indexing. Results: Differential images based on the reference and test signal frequencies were reconstructed from EIT data. Result illustrated distinct structural inhomogeneity in seeded region compared to fruit flesh. The seeded region was seen as a higherimpedance region if the test frequency was lower than the base frequency in the differential EIT reconstruction. When the test frequency was higher than the base frequency, the signal experienced less electrical impedance in the seeded region during the EIT data acquisition. Conclusion: Frequency-based differential EIT imaging can be explored to provide additional functional information along with structural information from CT for identifying different tissues.

  14. SU-E-I-52: Validation of Multi-Frequency Electrical Impedance Tomography Using Computed Tomography

    International Nuclear Information System (INIS)

    Kohli, K; Liu, F; Krishnan, K

    2014-01-01

    Purpose: Multi-frequency EIT has been reported to be a potential tool in distinguishing a tissue anomaly from background. In this study, we investigate the feasibility of acquiring functional information by comparing multi-frequency EIT images in reference to the structural information from the CT image through fusion. Methods: EIT data was acquired from a slice of winter melon using sixteen electrodes around the phantom, injecting a current of 0.4mA at 100, 66, 24.8 and 9.9 kHz. Differential EIT images were generated by considering different combinations of pair frequencies, one serving as reference data and the other as test data. The experiment was repeated after creating an anomaly in the form of an off-centered cavity of diameter 4.5 cm inside the melon. All EIT images were reconstructed using Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software (EIDORS) package in 2-D differential imaging mode using one-step Gaussian Newton minimization solver. CT image of the melon was obtained using a Phillips CT Scanner. A segmented binary mask image was generated based on the reference electrode position and the CT image to define the regions of interest. The region selected by the user was fused with the CT image through logical indexing. Results: Differential images based on the reference and test signal frequencies were reconstructed from EIT data. Result illustrated distinct structural inhomogeneity in seeded region compared to fruit flesh. The seeded region was seen as a higherimpedance region if the test frequency was lower than the base frequency in the differential EIT reconstruction. When the test frequency was higher than the base frequency, the signal experienced less electrical impedance in the seeded region during the EIT data acquisition. Conclusion: Frequency-based differential EIT imaging can be explored to provide additional functional information along with structural information from CT for identifying different tissues

  15. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography

    International Nuclear Information System (INIS)

    Kettler, Nele

    2011-01-01

    Imaging methods for early, accurate diagnosis and aftercare of malignant growths is currently one of the most important research topics. The objective of this thesis is to evaluate the diagnostic value of FDG-positron emission tomography by comparison with computed tomography for patients with squamous cell carcinoma, malignant melanoma or sarcoma at head and neck. Measurement criteria are sensitivity and specificity. A retrospective evaluation of 100 examinations on 85 patients of University clinic Aachen was performed. The examination reports were supported by reports from histology, positron emission tomography and computed tomography. In each case, the histological results were assumed to provide a reliable benchmark. Sensitivity and specificity for the primary tumour site, metastatic lymphatic nodes and defined anatomic structures were compared across all patients. Comparisons were also performed on sub groups separated by gender, cancer type and the time and frequency at which tumours arose. The statistic analysis was done with MedCalc. Results: The results for sensitivity and specificity of the primary tumour site were 86.42% and 42.86%, and 64.71% and 66.07%, for positron emission tomography and computed tomography respectively. The results for the lymphatic nodes were 51.52% and 92.86% and 64.71% and 66.07%. When the constituent anatomic structures were evaluated separately, the specificity was significantly higher. The separation by gender showed no difference. Because the classification by tumor type resulted in samples that were of varying size, a comparison was difficult. For the diagnosis of primary tumours, the examination with positron emission tomography was superior, whereas computed tomography proved more effective for the diagnosis of recurrent tumours. For the diagnosis of the main tumour site, both methods were shown to be equally suitable. For the assessment of lymphatic nodes, positron emission tomography was superior to computed tomography

  16. Dynamic positron emission tomography for study of cerebral hemodynamics in a cross section of the head using positron-emitting 68Ga-EDTA and 77Kr

    International Nuclear Information System (INIS)

    Yamamoto, Y.L.; Thompson, C.J.; Meyer, E.; Robertson, J.S.; Feindel, W.

    1977-01-01

    Dynamic positron emission tomographic studies were performed on over 120 patients with occlusive cerebrovascular disease, arteriovenous malformations, and brain tumors, using the positron section scanner, consisting of a ring of 32 scintillation detectors. The radiopharmaceuticals were nondiffusible 68 Ga-EDTA for transit time and uptake studies and the diffusible tracer, 77 Kr, for quantitative regional cerebral blood flow studies in every square centimeter of the cross section of the head. The results of dynamic positron emission tomography in correlation with the results from the gamma scintillation camera dynamic studies and computed tomography (CT) scans are discussed

  17. Gastrointestinal diseases in HIV-positive patients: ultrasonography and computed tomography in a study of 85 patients

    International Nuclear Information System (INIS)

    Garcia, S.; Yague, D.; Garcia, C.; Villalon, M.; Pascual, A.; Artigas, J.M.

    1998-01-01

    Gastrointestinal diseases constitute the second most common group conditions affecting HIV-positive patients after respiratory diseases. Gastrointestinal involvement may even be the first sign of the disease, a facto which demonstrates the importance of its proper assessment. To demonstrate the utility of computed tomography and ultrasound in the study of gastrointestinal and hepatobiliary diseases in the HIV-positive patient. We review a series of 85 HIV-positive patients presenting gastrointestinal symptomatology who underwent ultrasonography and/or computed tomography. the definitive diagnosis was achieved in all the patients by microbiological or histopathological means. In our series 36.4% the patients had presented systemic TB, 23.52% CMV infection, 17.64% Cryptosporidium infection and 17.64% MAI infection. Much lower incidences were found for Mycobacterium xenopi. M. kansai and Leishmania infection. The presence of lymphoma was confirmed in 7.05% of the patients and Koposi's sarcoma in 0.95%. In these patients, the most common finding on imaging studies in lymph node involvement, followed by diffuse hepatosplenomegaly. Imaging techniques, especially ultrasonography and computed tomography, are useful in these patients: although they do not provide the diagnosis, they do contribute data of prognostic and therapeutic importance. (Author) 11 refs

  18. Post-mortem computed tomography findings of the lungs: Retrospective review and comparison with autopsy results of 30 infant cases

    Energy Technology Data Exchange (ETDEWEB)

    Kawasumi, Yusuke, E-mail: ssu@rad.med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Clinical Imaging, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Usui, Akihito, E-mail: t7402r0506@med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Diagnostic Image Analysis, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Hosokai, Yoshiyuki, E-mail: hosokai@med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Diagnostic Image Analysis, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Igari, Yui, E-mail: igari@forensic.med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Forensic Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Hosoya, Tadashi [Tohoku University Graduate School of Medicine, Department of Forensic Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Hayashizaki, Yoshie, E-mail: yoshie@forensic.med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Forensic Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Saito, Haruo, E-mail: hsaito@med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Diagnostic Image Analysis, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Ishibashi, Tadashi, E-mail: tisibasi@med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Clinical Imaging, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Funayama, Masato, E-mail: funayama@forensic.med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Forensic Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan)

    2015-04-15

    Highlights: •Infant cases frequently show a diffuse increase in the concentration of lung fields on post-mortem computed tomography (PMCT). •In this study, twenty-two of the thirty sudden infant death cases showed increasing concentration in the entire lung field. •Based on the autopsy results, the lungs simply collapsed and no other abnormal lung findings were identified. •The radiologist should not consider increasing concentration in all lung fields as simply a pulmonary disorder when diagnosing the cause of infant death using PMCT. -- Abstract: Objectives: Infant cases frequently show a diffuse increase in the concentration of lung fields on post-mortem computed tomography (PMCT). However, the lungs often show simply atelectasis at autopsy in the absence of any other abnormal changes. Thus, we retrospectively reviewed the PMCT findings of lungs following sudden infant death and correlated them with the autopsy results. Materials and methods: We retrospectively reviewed infant cases (0 year) who had undergone PMCT and a forensic autopsy at our institution between May 2009 and June 2013. Lung opacities were classified according to their type; consolidation, ground-glass opacity and mixed, as well as distribution; bilateral diffuse and areas of sparing. Statistical analysis was performed to assess the relationships among lung opacities, causes of death and resuscitation attempt. Results: Thirty infant cases were selected, which included 22 sudden and unexplained deaths and 8 other causes of death. Resuscitation was attempted in 22 of 30 cases. Bilateral diffuse opacities were observed in 21 of the 30 cases. Of the 21 cases, 18 were sudden and unexplained deaths. Areas of sparing were observed in 4 sudden and unexplained deaths and 5 other causes of death. Distribution of opacities was not significantly associated with causes of death or resuscitation attempt. The 21 cases with bilateral diffuse opacities included 6 consolidations (4 sudden and unexplained

  19. Post-mortem computed tomography findings of the lungs: Retrospective review and comparison with autopsy results of 30 infant cases

    International Nuclear Information System (INIS)

    Kawasumi, Yusuke; Usui, Akihito; Hosokai, Yoshiyuki; Igari, Yui; Hosoya, Tadashi; Hayashizaki, Yoshie; Saito, Haruo; Ishibashi, Tadashi; Funayama, Masato

    2015-01-01

    Highlights: •Infant cases frequently show a diffuse increase in the concentration of lung fields on post-mortem computed tomography (PMCT). •In this study, twenty-two of the thirty sudden infant death cases showed increasing concentration in the entire lung field. •Based on the autopsy results, the lungs simply collapsed and no other abnormal lung findings were identified. •The radiologist should not consider increasing concentration in all lung fields as simply a pulmonary disorder when diagnosing the cause of infant death using PMCT. -- Abstract: Objectives: Infant cases frequently show a diffuse increase in the concentration of lung fields on post-mortem computed tomography (PMCT). However, the lungs often show simply atelectasis at autopsy in the absence of any other abnormal changes. Thus, we retrospectively reviewed the PMCT findings of lungs following sudden infant death and correlated them with the autopsy results. Materials and methods: We retrospectively reviewed infant cases (0 year) who had undergone PMCT and a forensic autopsy at our institution between May 2009 and June 2013. Lung opacities were classified according to their type; consolidation, ground-glass opacity and mixed, as well as distribution; bilateral diffuse and areas of sparing. Statistical analysis was performed to assess the relationships among lung opacities, causes of death and resuscitation attempt. Results: Thirty infant cases were selected, which included 22 sudden and unexplained deaths and 8 other causes of death. Resuscitation was attempted in 22 of 30 cases. Bilateral diffuse opacities were observed in 21 of the 30 cases. Of the 21 cases, 18 were sudden and unexplained deaths. Areas of sparing were observed in 4 sudden and unexplained deaths and 5 other causes of death. Distribution of opacities was not significantly associated with causes of death or resuscitation attempt. The 21 cases with bilateral diffuse opacities included 6 consolidations (4 sudden and unexplained

  20. Intramuscular diffuse-type giant cell tumor within the hamstring muscle

    International Nuclear Information System (INIS)

    Yoshida, Tatsuya; Sakamoto, Akio; Tanaka, Kazuhiro; Iwamoto, Yukihide; Oda, Yoshinao; Izumi, Teiyu; Tsuneyoshi, Masazumi

    2007-01-01

    Diffuse-type giant cell tumor (D-TGCT) is known as a synonym for pigmented villonodular synovitis (PVS), a condition usually found in the large joints. We report an extremely rare case of D-TGCT which was located within the hamstring muscle. The lesion was an incidental finding in a 62-year-old man who underwent positron emission tomography (PET) as part of a staging evaluation for gastric cancer. The lesion was resected. There has been neither metastasis nor recurrence during the 6-month period since resection. This case demonstrates that PVS/D-TGCT may have a high SUV on PET imaging, and for this reason PET may be useful for detecting both the tumor and any recurrence. (orig.)

  1. Meaning of Interior Tomography

    Science.gov (United States)

    Wang, Ge; Yu, Hengyong

    2013-01-01

    The classic imaging geometry for computed tomography is for collection of un-truncated projections and reconstruction of a global image, with the Fourier transform as the theoretical foundation that is intrinsically non-local. Recently, interior tomography research has led to theoretically exact relationships between localities in the projection and image spaces and practically promising reconstruction algorithms. Initially, interior tomography was developed for x-ray computed tomography. Then, it has been elevated as a general imaging principle. Finally, a novel framework known as “omni-tomography” is being developed for grand fusion of multiple imaging modalities, allowing tomographic synchrony of diversified features. PMID:23912256

  2. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  3. Positron emission tomography

    International Nuclear Information System (INIS)

    Wienhard, K.; Heiss, W.D.

    1984-01-01

    The principles and selected clinical applications of positron emission tomography are described. In this technique a chemical compound is labeled with a positron emitting isotope and its biochemical pathway is traced by coincidence detection of the two annihilation photons. The application of the techniques of computed tomography allows to reconstruct the spatial distribution of the radioactivity within a subject. The 18 F-deoxyglucose method for quantitative measurement of local glucose metabolism is discussed in order to illustrate the possibilities of positron emission tomography to record physiological processes in vivo. (orig.) [de

  4. Anisotropy in "isotropic diffusion" measurements due to nongaussian diffusion

    DEFF Research Database (Denmark)

    Jespersen, Sune Nørhøj; Olesen, Jonas Lynge; Ianuş, Andrada

    2017-01-01

    Designing novel diffusion-weighted NMR and MRI pulse sequences aiming to probe tissue microstructure with techniques extending beyond the conventional Stejskal-Tanner family is currently of broad interest. One such technique, multidimensional diffusion MRI, has been recently proposed to afford...... model-free decomposition of diffusion signal kurtosis into terms originating from either ensemble variance of isotropic diffusivity or microscopic diffusion anisotropy. This ability rests on the assumption that diffusion can be described as a sum of multiple Gaussian compartments, but this is often...

  5. Magnetic resonance imaging in diffuse brain injury

    International Nuclear Information System (INIS)

    Yokota, Hiroyuki; Yasuda, Kazuhiro; Mashiko, Kunihiro; Henmi, Hiroshi; Otsuka, Toshibumi; Kobayashi, Shiro; Nakazawa, Shozo

    1992-01-01

    Forty cases diagnosed as diffuse brain injury (DBI) were studied by magnetic resonance imaging (MRI) performed within 3 days after injury. These cases were divided into two groups, which were the concussion group and diffuse axonal injury (DAI) group established by Gennarelli. There were no findings on computerized tomography (CT) in the concussion group except for two cases which had a brain edema or subarachnoid hemorrhage. But on MRI, high intensity areas on T2 weighted imaging were demonstrated in the cerebral white matter in this group. Many lesions in this group were thought to be edemas of the cerebral white matter, because of the fact that on serial MRI, they were isointense. In mild types of DAI, the lesions on MRI were located only in the cerebral white matter, whereas, in the severe types of DAI, lesions were located in the basal ganglia, the corpus callosum, the dorsal part of the brain stem as well as in the cerebral white matter. As for CT findings, parenchymal lesions were not visualized especially in mild DAI. Our results suggested that the lesions in cerebral concussion were edemas in cerebral white matter. In mild DAI they were non-hemorrhagic contusion; and in severe DAI they were hemorrhagic contusions in the cerebral white matter, the basal ganglia, the corpus callosum or the dorsal part of the brain stem. (author)

  6. Study of effective transport properties of fresh and aged gas diffusion layers

    Science.gov (United States)

    Bosomoiu, Magdalena; Tsotridis, Georgios; Bednarek, Tomasz

    2015-07-01

    Gas diffusion layers (GDLs) play an important role in proton exchange membrane fuel cells (PEMFCs) for the diffusion of reactant and the removal of product water. In the current study fresh and aged GDLs (Sigracet® GDL34BC) were investigated by X-ray computed tomography to obtain a representative 3D image of the real GDL structure. The examined GDL samples are taken from areas located under the flow channel and under the land. Additionally, a brand new Sigracet® GDL34BC was taken as a reference sample in order to find out the impact of fuel cell assembly on GDL. The produced 3D image data were used to calculate effective transport properties such as thermal and electrical conductivity, diffusivity, permeability and capillary pressure curves of the dry and partially saturated GDL. The simulation indicates flooding by product water occurs at contact angles lower than 125° depending on sample porosity. In addition, GDL anisotropy significantly affects the permeability as well as thermal and electrical conductivities. The calculated material bulk properties could be next used as input for CFD modelling of PEM fuel cells where GDL is usually assumed layer-like and homogeneous. Tensor material parameters allow to consider GDL anisotropy and lead to more realistic results.

  7. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  8. Single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.

    1986-01-01

    Single photon tomography dates from the early 1960's when the idea of emission transverse section tomography was presented by Kuhl and Edwards. They used a rectilinear scanner and analogue back-projection methods to detect emissions from a series of sequential positions transverse to the cephaldcaudad axis of the body. This chapter presents an explanation of emission tomography by describing longitudinal and transverse section tomography. In principle all modes of tomography can be considered under the general topic of coded apertures wherein the code ranges from translation of a pinhole collimator to rotation of a parallel hole or focused collimator array

  9. Spatio-temporal imaging of the hemoglobin in the compressed breast with diffuse optical tomography

    Science.gov (United States)

    Boverman, Gregory; Fang, Qianqian; Carp, Stefan A.; Miller, Eric L.; Brooks, Dana H.; Selb, Juliette; Moore, Richard H.; Kopans, Daniel B.; Boas, David A.

    2007-07-01

    We develop algorithms for imaging the time-varying optical absorption within the breast given diffuse optical tomographic data collected over a time span that is long compared to the dynamics of the medium. Multispectral measurements allow for the determination of the time-varying total hemoglobin concentration and of oxygen saturation. To facilitate the image reconstruction, we decompose the hemodynamics in time into a linear combination of spatio-temporal basis functions, the coefficients of which are estimated using all of the data simultaneously, making use of a Newton-based nonlinear optimization algorithm. The solution of the extremely large least-squares problem which arises in computing the Newton update is obtained iteratively using the LSQR algorithm. A Laplacian spatial regularization operator is applied, and, in addition, we make use of temporal regularization which tends to encourage similarity between the images of the spatio-temporal coefficients. Results are shown for an extensive simulation, in which we are able to image and quantify localized changes in both total hemoglobin concentration and oxygen saturation. Finally, a breast compression study has been performed for a normal breast cancer screening subject, using an instrument which allows for highly accurate co-registration of multispectral diffuse optical measurements with an x-ray tomosynthesis image of the breast. We are able to quantify the global return of blood to the breast following compression, and, in addition, localized changes are observed which correspond to the glandular region of the breast.

  10. Thermal diffusion (1963); Diffusion thermique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Lemarechal, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    This report brings together the essential principles of thermal diffusion in the liquid and gaseous phases. The macroscopic and molecular aspects of the thermal diffusion constant are reviewed, as well as the various measurement method; the most important developments however concern the operation of the CLUSIUS and DICKEL thermo-gravitational column and its applications. (author) [French] Ce rapport rassemble les principes essentiels de la diffusion thermique en phase liquide et en phase gazeuse. Les aspects macroscopique et moleculaire de la constante de diffusion thermique sont passes en revue ainsi que ses differentes methodes de mesure; mais les developpements les plus importants concernent le fonctionnement de ls colonne thermogravitationnelle de CLUSIUS et DICKEL et ses applications. (auteur)

  11. Tomography

    International Nuclear Information System (INIS)

    Barrett, H.H.; Gordon, S.; Swindell, W.

    1980-01-01

    Apparatus is described for generating a two-dimensional back-projected image of a slice of an object in tomography. The apparatus uses optical techniques to perform the functions of filtering and back projection. Central to the technique is a cylindrical drum which rotates at a fast rate and whose rotational axis tilts at a slower rate. The novel method overcomes the problem of image blurring due to motion which occurs in many tomographic techniques. It also has the advantages of being less expensive and simpler compared to tomography using digital processing techniques which require fast computers. (UK)

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  13. Diffuse Hepatic Calcifications in a Transfusion-Dependent Patient with Beta-Thalassemia: A Case Report

    Directory of Open Access Journals (Sweden)

    Forough Saki

    2013-09-01

    Full Text Available Hepatic calcification is usually associated with infectious, vascular, or neoplastic processes in the liver. We report the first case of beta-thalassemia major with isolated diffuse hepatic calcification in a 23 year old woman, who had been transfusion-dependent since the age of 6 months. She was referred to our center with a chief complaint of abdominal pain. Computed tomography scan of the abdomen revealed diffuse hepatic calcification in the right, left, and caudate lobes of the liver. Her medical history disclosed hypoparathyroidism as well as chronic hepatitis C virus infection, which was successfully treated but led to early micronodular cirrhosis on liver biopsy. Other studies done to search for the cause of hepatic calcification failed to reveal any abnormalities. We suspect that hypoparathyroidism caused liver calcification, and should be, therefore, considered in the differential diagnosis of hepatic calcification if other causative factors have been ruled out.

  14. The impact of iterative reconstruction in low-dose computed tomography on the evaluation of diffuse interstitial lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Hyun Ju; Chung, Myung Jin; Shin, Kyung Eun; Hwang, Hye Sun; Lee, Kyung Soo [Dept. of Radiology nd Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-11-15

    To evaluate the impact of iterative reconstruction (IR) on the assessment of diffuse interstitial lung disease (DILD) using CT. An American College of Radiology (ACR) phantom (module 4 to assess spatial resolution) was scanned with 10-100 effective mAs at 120 kVp. The images were reconstructed using filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), with blending ratios of 0%, 30%, 70% and 100%, and model-based iterative reconstruction (MBIR), and their spatial resolution was objectively assessed by the line pair structure method. The patient study was based on retrospective interpretation of prospectively acquired data, and it was approved by the institutional review board. Chest CT scans of 23 patients (mean age 64 years) were performed at 120 kVp using 1) standard dose protocol applying 142-275 mA with dose modulation (high-resolution computed tomography [HRCT]) and 2) low-dose protocol applying 20 mA (low dose CT, LDCT). HRCT images were reconstructed with FBP, and LDCT images were reconstructed using FBP, ASIR, and MBIR. Matching images were randomized and independently reviewed by chest radiologists. Subjective assessment of disease presence and radiological diagnosis was made on a 10-point scale. In addition, semi-quantitative results were compared for the extent of abnormalities estimated to the nearest 5% of parenchymal involvement. In the phantom study, ASIR was comparable to FBP in terms of spatial resolution. However, for MBIR, the spatial resolution was greatly decreased under 10 mA. In the patient study, the detection of the presence of disease was not significantly different. The values for area under the curve for detection of DILD by HRCT, FBP, ASIR, and MBIR were as follows: 0.978, 0.979, 0.972, and 0.963. LDCT images reconstructed with FBP, ASIR, and MBIR tended to underestimate reticular or honeycombing opacities (-2.8%, -4.1%, and -5.3%, respectively) and overestimate ground glass opacities (+4.6%, +8.9%, and

  15. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  16. Iterative methods for tomography problems: implementation to a cross-well tomography problem

    Science.gov (United States)

    Karadeniz, M. F.; Weber, G. W.

    2018-01-01

    The velocity distribution between two boreholes is reconstructed by cross-well tomography, which is commonly used in geology. In this paper, iterative methods, Kaczmarz’s algorithm, algebraic reconstruction technique (ART), and simultaneous iterative reconstruction technique (SIRT), are implemented to a specific cross-well tomography problem. Convergence to the solution of these methods and their CPU time for the cross-well tomography problem are compared. Furthermore, these three methods for this problem are compared for different tolerance values.

  17. Fluorodeoxyglucose-positron emission tomography/computed tomography imaging features of colloid adenocarcinoma of the lung: a case report.

    Science.gov (United States)

    Wang, ZhenGuang; Yu, MingMing; Chen, YueHua; Kong, Yan

    2017-07-27

    Colloid adenocarcinoma of the lung is a rare subtype of variants of invasive adenocarcinomas. We report the appearance of this unusual entity on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography. A 60-year-old man of Chinese Han nationality coughed with a little white sputum for 1 month. Chest computed tomography showed multiple bilateral subpleural nodules and plaques accompanied by air bronchograms, which were most concentrated in the lower lobe of his right lung. Positron emission tomography indicated increased radioactivity uptake with a maximum standardized uptake value of 3.5. Positron emission tomography/computed tomography showed a soft tissue density lesion in his left adrenal gland with a maximum standardized uptake value of 4.1. The positron emission tomography/computed tomography appearance suggested a primary colloid adenocarcinoma in the lower lobe of his right lung accompanied by intrapulmonary and left adrenal gland metastases. The diagnostic rate of colloid adenocarcinoma can be increased by combining the anatomic and metabolic information of lesions. The advantage of positron emission tomography/computed tomography in the diagnosis of colloid adenocarcinoma, as with other cancers, is the ability to locate extrapulmonary disease, facilitating clinical staging.

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  20. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  1. Incidental head and neck findings on 18F-fluoro-deoxy-glucose positron emission tomography computed tomography.

    Science.gov (United States)

    Williams, S P; Kinshuck, A J; Williams, C; Dwivedi, R; Wieshmann, H; Jones, T M

    2015-09-01

    The overlapping risk factors for lung and head and neck cancer present a definite risk of synchronous malignant pathology. This is the first study to specifically review incidental positron emission tomography computed tomography findings in the head and neck region in lung carcinoma patients. A retrospective review was performed of all lung cancer patients who underwent positron emission tomography computed tomography imaging over a five-year period (January 2008 - December 2012), identified from the Liverpool thoracic multidisciplinary team database. Six hundred and nine patients underwent positron emission tomography computed tomography imaging over this period. In 76 (12.5 per cent) scans, incidental regions of avid 18F-fluoro-deoxy-glucose uptake were reported in the head and neck region. In the 28 patients who were fully investigated, there were 4 incidental findings of malignancy. In lung cancer patients undergoing investigative positron emission tomography computed tomography scanning, a significant number will also present with areas of clinically significant 18F-fluoro-deoxy-glucose uptake in the head and neck region. Of these, at least 5 per cent may have an undiagnosed malignancy.

  2. Optical biopsy of lymph node morphology using optical coherence tomography.

    Science.gov (United States)

    Luo, Wei; Nguyen, Freddy T; Zysk, Adam M; Ralston, Tyler S; Brockenbrough, John; Marks, Daniel L; Oldenburg, Amy L; Boppart, Stephen A

    2005-10-01

    Optical diagnostic imaging techniques are increasingly being used in the clinical environment, allowing for improved screening and diagnosis while minimizing the number of invasive procedures. Diffuse optical tomography, for example, is capable of whole-breast imaging and is being developed as an alternative to traditional X-ray mammography. While this may eventually be a very effective screening method, other optical techniques are better suited for imaging on the cellular and molecular scale. Optical Coherence Tomography (OCT), for instance, is capable of high-resolution cross-sectional imaging of tissue morphology. In a manner analogous to ultrasound imaging except using optics, pulses of near-infrared light are sent into the tissue while coherence-gated reflections are measured interferometrically to form a cross-sectional image of tissue. In this paper we apply OCT techniques for the high-resolution three-dimensional visualization of lymph node morphology. We present the first reported OCT images showing detailed morphological structure and corresponding histological features of lymph nodes from a carcinogen-induced rat mammary tumor model, as well as from a human lymph node containing late stage metastatic disease. The results illustrate the potential for OCT to visualize detailed lymph node structures on the scale of micrometastases and the potential for the detection of metastatic nodal disease intraoperatively.

  3. An introduction to emission computed tomography

    International Nuclear Information System (INIS)

    Williams, E.D.

    1985-01-01

    This report includes salient features of the theory and an examination of practical considerations for someone who is using or introducing tomography, selecting equipment for it or wishing to develop a clinical application. Emphasis is on gamma camera tomography. The subject is dealt with under the following headings: emission computed and gamma camera tomography and the relationship to other medical imaging techniques, the tomographic reconstruction technique theory, rotating gamma camera tomography, attenuation correction and quantitative reconstruction, other single photon tomographic techniques, positron tomography, image display, clinical application of single photon and positron tomography, and commercial systems for SPECT. Substantial bibliography. (U.K.)

  4. Evaluation of Laser-Assisted Trans-Nail Drug Delivery with Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Meng-Tsan Tsai

    2016-12-01

    Full Text Available The nail provides a functional protection to the fingertips and surrounding tissue from external injuries. The nail plate consists of three layers including dorsal, intermediate, and ventral layers. The dorsal layer consists of compact, hard keratins, limiting topical drug delivery through the nail. In this study, we investigate the application of fractional CO2 laser that produces arrays of microthermal ablation zones (MAZs to facilitate drug delivery in the nails. We utilized optical coherence tomography (OCT for real-time monitoring of the laser–skin tissue interaction, sparing the patient from an invasive surgical sampling procedure. The time-dependent OCT intensity variance was used to observe drug diffusion through an induced MAZ array. Subsequently, nails were treated with cream and liquid topical drugs to investigate the feasibility and diffusion efficacy of laser-assisted drug delivery. Our results show that fractional CO2 laser improves the effectiveness of topical drug delivery in the nail plate and that OCT could potentially be used for in vivo monitoring of the depth of laser penetration as well as real-time observations of drug delivery.

  5. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  6. Cardiac positron emission tomography

    International Nuclear Information System (INIS)

    Eftekhari, M.; Ejmalian, G.

    2003-01-01

    Positron emission tomography is an intrinsically tool that provide a unique and unparalleled approach for clinicians and researchers to interrogate the heart noninvasively. The ability to label substances of physiological interest with positron-emitting radioisotopes has permitted insight into normal blood flow and metabolism and the alterations that occur with disease states. Positron emission tomography of the heart has evolved as a unique, noninvasive approach for the assessment of myocardial perfusion, metabolism, and function. Because of the intrinsic quantitative nature of positron emission tomography measurements as well as the diverse compounds that can be labeled with positron- emitting radioisotopes, studies with positron emission tomography have provided rich insight into the physiology of the heart under diverse conditions

  7. Positron emission tomography with Positome, 2

    International Nuclear Information System (INIS)

    Nukui, Hideaki; Yamamoto, Y.L.; Thompson, C.J.; Feindel, W.

    1979-01-01

    Positron emission tomography with Positome II using 68 Ga-EDTA was performed in cases with brain tumor and cerebral arteriovenous malformation. A significant focal uptake in static study and hemodynamic changes in dynamic study were noted in all cases except one case with intracranial lipoma. Comparing this method with sup(99m) Tc-pertechnetate cerebral image study and computerized axial tomography, the diagnostic rate for detecting brain tumor was almost equal in all of these three methods. However, detecting and localizing was easier and clearer in static positron emission tomography with 68 Ga-EDTA than in sup(99m) Tc-pertechnetate cerebral image and computerized axial tomography without infusion of contrast medium. Furthermore, static positron emission tomography with 68 Ga-EDTA was superior to computerized axial tomography without infusion of contrast medium for detecting cerebral arteriovenous malformation. Concerning dynamic positron emission tomography with 68 Ga-EDTA, semiquantitative values obtained by this method correlated well with findings of computerized axial tomography and was thought to be more precise and in detail than the findings of sup(99m) Tc-pertechnetate cerebral image study. Summation of the previous studies about dynamic positron emission tomography with 77 Kr in occlusive cerebrovascular disease is also reported. In conclusion, static positron emission tomography with 68 Ga-EDTA is a very useful diagnostic method for detecting and localizing brain tumor and cerebral arteriovenous malformation without any attendant complications. Furthermore, a good combination of static and dynamic positron emission tomography and computerized axial tomography appear to be outstandingly effective for not only detecting the lesion but also understanding the pathophysiological aspect in cases with various intracranial lesions. (author)

  8. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  9. A fast and accurate imaging algorithm in optical/diffusion tomography

    Science.gov (United States)

    Klibanov, M. V.; Lucas, T. R.; Frank, R. M.

    1997-10-01

    An n-dimensional (n = 2,3) inverse problem for the parabolic/diffusion equation 0266-5611/13/5/015/img1, 0266-5611/13/5/015/img2, 0266-5611/13/5/015/img3, 0266-5611/13/5/015/img4 is considered. The problem consists of determining the function a(x) inside of a bounded domain 0266-5611/13/5/015/img5 given the values of the solution u(x,t) for a single source location 0266-5611/13/5/015/img6 on a set of detectors 0266-5611/13/5/015/img7, where 0266-5611/13/5/015/img8 is the boundary of 0266-5611/13/5/015/img9. A novel numerical method is derived and tested. Numerical tests are conducted for n = 2 and for ranges of parameters which are realistic for applications to early breast cancer diagnosis and the search for mines in murky shallow water using ultrafast laser pulses. The main innovation of this method lies in a new approach for a novel linearized problem (LP). Such a LP is derived and reduced to a well-posed boundary-value problem for a coupled system of elliptic partial differential equations. A principal advantage of this technique is in its speed and accuracy, since it leads to the factorization of well conditioned, sparse matrices with non-zero entries clustered in a narrow band near the diagonal. The authors call this approach the elliptic systems method (ESM). The ESM can be extended to other imaging modalities.

  10. Comparison of computer tomography and magnetic resonance tomography in the diagnosis of intracerebral hemorrhage

    International Nuclear Information System (INIS)

    Kuhn, S.; Elste, V.; Sartor, K.; Reith, W.; Ertl-Wagner, B.; Muenchen Univ.

    1999-01-01

    Background and Purpose: Stroke symptoms are caused in 10 to 15% by intracerebral hemorrhage. From the clinical examination it is often impossible to differentiate intracerebralhemorrhage from cerebral ischemia. To exclude intracerebral hemorrhage as the cause of clinical symptoms a CT is usually performed. The aim of our study was a direct comparison of the sensitivity of Computed Tomography and MRI using different MR sequences for the detection of acute intracerebral hemorrhage. Methods: In 8 male Wistar rats intracerebral hemorrhage was induced by infusion of collagenase into the caudate nucleus. After 1 hour the brains were subsequently imaged with CT and MRI using T2- and T1-weighted Spin Echo sequences, diffusion-weighted sequences, T2*-weighted gradient echo sequences and FLAIR-sequences. Visibility of the intracerebral hemorrhage was examined using a scoring system for 1=not visible to 5=excellent visible. Finally, the intracerebral hemorrhage was verified by histological staining. Results: In all animals, intracerebral hemorrhage was visible in T2*-weighted gradient echo and diffusion weighted MR images 1 h after infusion of collagenase. T2- and PD-weighted SE images were positive in 7/8 rats. T1-weighted images revealed signal changes in 5/8 rats, and FLAIR sequence was positive in 8/8 rats. In CT intracerebral hemorrhage was only visible in 3/8 rats. When measuring the increase of Hounsfield units within the suspected hemisphere we saw a mean increase of 7% compared to the normal hemisphere in 3/8 rats. Conclusions: In this animal model, T2*-weighted magnetic resonance imaging proved to be the most sensitive imaging modality in the detection of acute intracerebral hemorrhage and is by far more sensitive than CT. (orig.) [de

  11. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and

  12. Diffusion tensor imaging of the optic tracts in multiple sclerosis: association with retinal thinning and visual disability.

    Science.gov (United States)

    Dasenbrock, Hormuzdiyar H; Smith, Seth A; Ozturk, Arzu; Farrell, Sheena K; Calabresi, Peter A; Reich, Daniel S

    2011-04-01

    Visual disability is common in multiple sclerosis, but its relationship to abnormalities of the optic tracts remains unknown. Because they are only rarely affected by lesions, the optic tracts may represent a good model for assessing the imaging properties of normal-appearing white matter in multiple sclerosis. Whole-brain diffusion tensor imaging was performed on 34 individuals with multiple sclerosis and 26 healthy volunteers. The optic tracts were reconstructed by tractography, and tract-specific diffusion indices were quantified. In the multiple-sclerosis group, peripapillary retinal nerve-fiber-layer thickness and total macular volume were measured by optical coherence tomography, and visual acuity at 100%, 2.5%, and 1.25% contrast was examined. After adjusting for age and sex, optic-tract mean and perpendicular diffusivity were higher (P=.002) in multiple sclerosis. Lower optic-tract fractional anisotropy was correlated with retinal nerve-fiber-layer thinning (r=.51, P=.003) and total-macular-volume reduction (r=.59, P=.002). However, optic-tract diffusion indices were not specifically correlated with visual acuity or with their counterparts in the optic radiation. Optic-tract diffusion abnormalities are associated with retinal damage, suggesting that both may be related to optic-nerve injury, but do not appear to contribute strongly to visual disability in multiple sclerosis. Copyright © 2010 by the American Society of Neuroimaging.

  13. Diffusion of Zonal Variables Using Node-Centered Diffusion Solver

    Energy Technology Data Exchange (ETDEWEB)

    Yang, T B

    2007-08-06

    Tom Kaiser [1] has done some preliminary work to use the node-centered diffusion solver (originally developed by T. Palmer [2]) in Kull for diffusion of zonal variables such as electron temperature. To avoid numerical diffusion, Tom used a scheme developed by Shestakov et al. [3] and found their scheme could, in the vicinity of steep gradients, decouple nearest-neighbor zonal sub-meshes leading to 'alternating-zone' (red-black mode) errors. Tom extended their scheme to couple the sub-meshes with appropriate chosen artificial diffusion and thereby solved the 'alternating-zone' problem. Because the choice of the artificial diffusion coefficient could be very delicate, it is desirable to use a scheme that does not require the artificial diffusion but still able to avoid both numerical diffusion and the 'alternating-zone' problem. In this document we present such a scheme.

  14. Gamma tomography apparatus

    International Nuclear Information System (INIS)

    Span, F.J.

    1988-01-01

    The patent concerns a gamma tomography apparatus for medical diagnosis. The apparatus comprises a gamma scintillation camera head and a suspension system for supporting and positioning the camera head with respect for the patient. Both total body scanning and single photon emission tomography can be carried out with the apparatus. (U.K.)

  15. Computerised Axial Tomography (CAT)

    Science.gov (United States)

    1990-06-01

    Ministry of’ Defence, Defence Research Information Centre, UK. Computerised Axial Tomography ( CAT ) Report Secufty C"uMiauion tide Onadtiicadon (U. R, Cor S...DRIC T 8485 COMPUTERISED AXIAL TOMOGRAPHY ( CAT ) F.P. GENTILE, F. SABETTA, V. TRO1* ISS R 78/4.Rome, 1.5 Mlarch 1978 (from Italian) B Distribution(f...dello Radiazioni ISSN 0390--6477 F.P. GENTILE, F. SABETTA. V. TROI Computerised Axial Tomography ( CAT ) March 15, 1978). This paper is a review of

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  17. Fractional diffusion equations and anomalous diffusion

    CERN Document Server

    Evangelista, Luiz Roberto

    2018-01-01

    Anomalous diffusion has been detected in a wide variety of scenarios, from fractal media, systems with memory, transport processes in porous media, to fluctuations of financial markets, tumour growth, and complex fluids. Providing a contemporary treatment of this process, this book examines the recent literature on anomalous diffusion and covers a rich class of problems in which surface effects are important, offering detailed mathematical tools of usual and fractional calculus for a wide audience of scientists and graduate students in physics, mathematics, chemistry and engineering. Including the basic mathematical tools needed to understand the rules for operating with the fractional derivatives and fractional differential equations, this self-contained text presents the possibility of using fractional diffusion equations with anomalous diffusion phenomena to propose powerful mathematical models for a large variety of fundamental and practical problems in a fast-growing field of research.

  18. Fanconi anaemia with bilateral diffuse pulmonary arterio venous fistulae: a case report

    Directory of Open Access Journals (Sweden)

    Samarakoon Lasitha

    2012-03-01

    Full Text Available Abstract Background We report a patient with cytogenetically confirmed Fanconi anaemia with associated diffuse bilateral pulmonary arterio-venous fistulae. This is only the second reported case of diffuse pulmonary arterio-venous fistulae with Fanconi anaemia. Case Presentation A 16 year old Sri Lankan boy, with a cytogenetically confirmed Fanconi anaemia was admitted to University Medical Unit, National Hospital of Sri Lanka for further assessment and treatment. Both central and peripheral cyanosis plus clubbing were noted on examination. The peripheral saturation was persistently low on room air and did not improve with supplementary Oxygen. Contrast echocardiography failed to demonstrate an intra cardiac shunt but showed early crossover of contrast, suggesting the possibility of pulmonary arterio-venous fistulae. Computed tomography pulmonary angiogram was inconclusive. Subsequent right heart catheterisation revealed bilateral diffuse arterio-venous fistulae not amenable for device closure or surgical intervention. Conclusion To our knowledge, this is the second reported patient with diffuse pulmonary arterio-venous fistulae associated with Fanconi anaemia. We report this case to create awareness among clinicians regarding this elusive association. We recommend screening patients with Fanconi anaemia using contrast echocardiography at the time of assessment with transthoracic echocardiogram. Though universal screening may be impossible given the cost constraints, such screening should at least be performed in patients with clinical evidence of desaturation or when a therapeutic option such as haematopoietic stem cell transplantation is considered. Treatment of pulmonary arteriovenous fistulae would improve patient outcome as desaturation by shunting worsens the anaemic symptoms by reducing the oxygen carrying capacity of blood.

  19. Diffusion in solids

    International Nuclear Information System (INIS)

    Tiwari, G.P.; Kale, G.B.; Patil, R.V.

    1999-01-01

    The article presents a brief survey of process of diffusion in solids. It is emphasised that the essence of diffusion is the mass transfer through the atomic jumps. To begin with formal equations for diffusion coefficient are presented. This is followed by discussions on mechanisms of diffusion. Except for solutes which form interstitial solid solution, diffusion in majority of cases is mediated through exchange of sites between an atom and its neighbouring vacancy. Various vacancy parameters such as activation volume, correlation factor, mass effect etc are discussed and their role in establishing the mode of diffusion is delineated. The contribution of dislocations and grain boundaries in diffusion process is brought out. The experimental determination of different types of diffusion coefficients are described. Finally, the pervasive nature of diffusion process in number of commercial processes is outlined to show the importance of diffusion studies in materials science and technology. (author)

  20. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  1. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  2. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  3. Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed tomography

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2009-12-01

    Full Text Available "nBackground and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT and computed tomography (CT."nMaterials and Methods: Thermoluminescent dosimeters (TLD were implanted in 14 sites of RANDO phantom to measure average tissue absorbed dose in thyroid gland, parotid glands, submandibular glands, sublingual gland, lenses and buccal skin. The Promax (PLANMECA, Helsinki, Finland unit was selected for Panoramic, conventional linear tomography and cone beam computed tomography examinations and spiral Hispeed/Fxi (General Electric,USA was selected for CT examination. The average tissue absorbed doses were used for the calculation of the equivalent and effective doses in each organ."nResults: The average absorbed dose for Panoramic ranged from 0.038 mGY (Buccal skin to 0.308 mGY (submandibular gland, linear tomography ranged from 0.048 mGY (Lens to 0.510 mGY (submandibular gland,CBCT ranged from 0.322 mGY (thyroid glad to 1.144 mGY (Parotid gland and in CT ranged from 2.495 mGY (sublingual gland to 3.424 mGY (submandibular gland. Total effective dose in CBCT is 5 times greater than Panoramic and 4 times greater than linear tomography, and in CT, 30 and 22 times greater than Panoramic and linear tomography, respectively. Total effective dose in CT is 6 times greater than CBCT."nConclusion: For obtaining 3-dimensional (3D information in maxillofacial region, CBCT delivers the lower dose than CT, and should be preferred over a medical CT imaging. Furthermore, during maxillofacial imaging, salivary glands receive the highest dose of radiation.

  4. Intrathoracic manifestations of collagen vascular diseases on high-resolution chest computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Silva, C. Isabela S. [University of British Columbia, Vancouver (Canada). Vancouver General Hospital]. E-mail: isabela.silva@vch.ca; Mueller, Nestor L. [University of British Columbia, Vancouver (Canada). Vancouver General Hospital. Dept. of Radiology

    2008-05-15

    Intrathoracic manifestations of collagen vascular diseases are very common. The frequency of intrathoracic manifestations and the patterns of abnormality are variable depending on the type of collagen vascular disease and may simultaneously involve one or more of the following: lung parenchyma, airways, pulmonary vessels, pericardium, and pleura. The most common pulmonary manifestations are diffuse interstitial pneumonia and pulmonary hypertension which together represent the main causes of morbidity and mortality of these patients. Pulmonary, airway and pleural involvement may also be secondary to the disease therapy, or result from bacterial pneumonia or opportunistic infection. In the present review, the authors summarize the main intrathoracic manifestations of collagen vascular diseases and the differential diagnosis on high-resolution chest computed tomography. (author)

  5. Comparison of [11C]choline Positron Emission Tomography With T2- and Diffusion-Weighted Magnetic Resonance Imaging for Delineating Malignant Intraprostatic Lesions

    International Nuclear Information System (INIS)

    Chang, Joe H.; Lim Joon, Daryl; Davis, Ian D.; Lee, Sze Ting; Hiew, Chee-Yan; Esler, Stephen; Gong, Sylvia J.; Wada, Morikatsu; Clouston, David; O'Sullivan, Richard; Goh, Yin P.; Bolton, Damien; Scott, Andrew M.; Khoo, Vincent

    2015-01-01

    Purpose: The purpose of this study was to compare the accuracy of [ 11 C]choline positron emission tomography (CHOL-PET) with that of the combination of T2-weighted and diffusion-weighted (T2W/DW) magnetic resonance imaging (MRI) for delineating malignant intraprostatic lesions (IPLs) for guiding focal therapies and to investigate factors predicting the accuracy of CHOL-PET. Methods and Materials: This study included 21 patients who underwent CHOL-PET and T2W/DW MRI prior to radical prostatectomy. Two observers manually delineated IPL contours for each scan, and automatic IPL contours were generated on CHOL-PET based on varying proportions of the maximum standardized uptake value (SUV). IPLs identified on prostatectomy specimens defined reference standard contours. The imaging-based contours were compared with the reference standard contours using Dice similarity coefficient (DSC), and sensitivity and specificity values. Factors that could potentially predict the DSC of the best contouring method were analyzed using linear models. Results: The best automatic contouring method, 60% of the maximum SUV (SUV 60 ) , had similar correlations (DSC: 0.59) with the manual PET contours (DSC: 0.52, P=.127) and significantly better correlations than the manual MRI contours (DSC: 0.37, P<.001). The sensitivity and specificity values were 72% and 71% for SUV 60 ; 53% and 86% for PET manual contouring; and 28% and 92% for MRI manual contouring. The tumor volume and transition zone pattern could independently predict the accuracy of CHOL-PET. Conclusions: CHOL-PET is superior to the combination of T2W/DW MRI for delineating IPLs. The accuracy of CHOL-PET is insufficient for gland-sparing focal therapies but may be accurate enough for focal boost therapies. The transition zone pattern is a new classification that may predict how well CHOL-PET delineates IPLs

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  7. Increasing the Accuracy of Volume and ADC Delineation for Heterogeneous Tumor on Diffusion-Weighted MRI: Correlation with PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Nan-Jie [Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong (China); Wong, Chun-Sing, E-mail: drcswong@gmail.com [Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong (China); Chu, Yiu-Ching [Department of Radiology, Kwong Wah Hospital, Hong Kong (China); Guo, Hua [Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing (China); Huang, Bingsheng [Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong (China); Chan, Queenie [Philips Healthcare, Hong Kong (China)

    2013-10-01

    Purpose: To improve the accuracy of volume and apparent diffusion coefficient (ADC) measurements in diffusion-weighted magnetic resonance imaging (MRI), we proposed a method based on thresholding both the b0 images and the ADC maps. Methods and Materials: In 21 heterogeneous lesions from patients with metastatic gastrointestinal stromal tumors (GIST), gross lesion were manually contoured, and corresponding volumes and ADCs were denoted as gross tumor volume (GTV) and gross ADC (ADC{sub g}), respectively. Using a k-means clustering algorithm, the probable high-cellularity tumor tissues were selected based on b0 images and ADC maps. ADC and volume of the tissues selected using the proposed method were denoted as thresholded ADC (ADC{sub thr}) and high-cellularity tumor volume (HCTV), respectively. The metabolic tumor volume (MTV) in positron emission tomography (PET)/computed tomography (CT) was measured using 40% maximum standard uptake value (SUV{sub max}) as the lower threshold, and corresponding mean SUV (SUV{sub mean}) was also measured. Results: HCTV had excellent concordance with MTV according to Pearson's correlation (r=0.984, P<.001) and linear regression (slope = 1.085, intercept = −4.731). In contrast, GTV overestimated the volume and differed significantly from MTV (P=.005). ADC{sub thr} correlated significantly and strongly with SUV{sub mean} (r=−0.807, P<.001) and SUV{sub max} (r=−0.843, P<.001); both were stronger than those of ADC{sub g}. Conclusions: The proposed lesion-adaptive semiautomatic method can help segment high-cellularity tissues that match hypermetabolic tissues in PET/CT and enables more accurate volume and ADC delineation on diffusion-weighted MR images of GIST.

  8. Diffusion in Solids Fundamentals, Methods, Materials, Diffusion-Controlled Processes

    CERN Document Server

    Mehrer, Helmut

    2007-01-01

    Diffusion is a vital topic in solid-state physics and chemistry, physical metallurgy and materials science. Diffusion processes are ubiquitous in solids at elevated temperatures. A thorough understanding of diffusion in materials is crucial for materials development and engineering. This book first gives an account of the central aspects of diffusion in solids, for which the necessary background is a course in solid state physics. It then provides easy access to important information about diffuson in metals, alloys, semiconductors, ion-conducting materials, glasses and nanomaterials. Several diffusion-controlled phenomena, including ionic conduction, grain-boundary and dislocation pipe diffusion, are considered as well. Graduate students in solid-state physics, physical metallurgy, materials science, physical and inorganic chemistry or geophysics will benefit from this book as will physicists, chemists, metallurgists, materials engineers in academic and industrial research laboratories.

  9. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer.

    Science.gov (United States)

    Yang, Zhongyi; Pan, Lingling; Cheng, Jingyi; Hu, Silong; Xu, Junyan; Ye, Dingwei; Zhang, Yingjian

    2012-07-01

    To investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity = 95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. © 2012 The Japanese Urological Association.

  10. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer

    International Nuclear Information System (INIS)

    Yang Zhongyi; Pan Lingling; Cheng Jingyi; Hu Silong; Xu Junyan; Zhang Yingjian; Ye Dingwei

    2012-01-01

    The objective of this study was to investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity=95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. (author)

  11. Principles and implementation of diffusion-weighted and diffusion tensor imaging

    International Nuclear Information System (INIS)

    Roberts, Timothy P.L.; Schwartz, E.S.

    2007-01-01

    We review the physiological basis of diffusion-weighted imaging and discuss the implementation of diffusion-weighted imaging pulse sequences and the subsequent postprocessing to yield quantitative estimations of diffusion parameters. We also introduce the concept of directionality of ''apparent'' diffusion in vivo and the means of assessing such anisotropy quantitatively. This in turn leads to the methodological application of diffusion tensor imaging and the subsequent postprocessing, known as tractography. The following articles deal with the clinical applications enabled by such methodologies. (orig.)

  12. Diffusion archeology for diffusion progression history reconstruction

    OpenAIRE

    Sefer, Emre; Kingsford, Carl

    2015-01-01

    Diffusion through graphs can be used to model many real-world processes, such as the spread of diseases, social network memes, computer viruses, or water contaminants. Often, a real-world diffusion cannot be directly observed while it is occurring — perhaps it is not noticed until some time has passed, continuous monitoring is too costly, or privacy concerns limit data access. This leads to the need to reconstruct how the present state of the diffusion came to be from partial d...

  13. Comparison of positron emission tomography/CT and bremsstrahlung imaging following Y-90 radiation synovectomy

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Yap, Kenneth S.K.; Cherk, Martin H.; Kalff, Victor; Powell, Anne

    2013-01-01

    The aim of this study is to compare the results of positron emission tomography (PET)/CT with bremsstrahlung imaging following Y-90 radiation synovectomy. All patients referred to our institution for Y-90 radiation synovectomy between July 2011 and February 2012 underwent both PET/CT and bremsstrahlung planar (±single photon emission computed tomography (SPECT) or SPECT/CT) imaging at 4 or 24 h following administration of Y-90 silicate colloid. PET image acquisition was performed for between 15 and 20min. In patients who underwent SPECT, side-by-side comparison with PET was performed and image quality/resolution scored using a five-point scale. The distribution pattern of Y-90 on PET and bremsstrahlung imaging was compared with the intra- or extra-articular location of Y-90 activity on fused PET/CT. Thirteen joints (11 knees and two ankles) were imaged with both PET/CT and planar bremsstrahlung imaging with 12 joints also imaged with bremsstrahlung SPECT. Of the 12 joints imaged with SPECT, PET image quality/resolution was superior in 11 and inferior in one. PET demonstrated a concordant distribution pattern compared with bremsstrahlung imaging in all scans, with the pattern classified as diffuse in 12 and predominantly focal in one. In all 12 diffuse scans, PET/CT confirmed the Y-90 activity to be located intra-articularly. In the one predominantly focal scan, the fused PET/CT images localised the Y-90 activity to mostly lie in the extra-articular space of the knee. PET/CT can provide superior image quality compared with bremsstrahlung imaging and may enable reliable detection of extra-articular Y-90 activity when there are focal patterns on planar bremsstrahlung imaging.

  14. Spatial Mapping of Translational Diffusion Coefficients Using Diffusion Tensor Imaging: A Mathematical Description.

    Science.gov (United States)

    Shetty, Anil N; Chiang, Sharon; Maletic-Savatic, Mirjana; Kasprian, Gregor; Vannucci, Marina; Lee, Wesley

    2014-01-01

    In this article, we discuss the theoretical background for diffusion weighted imaging and diffusion tensor imaging. Molecular diffusion is a random process involving thermal Brownian motion. In biological tissues, the underlying microstructures restrict the diffusion of water molecules, making diffusion directionally dependent. Water diffusion in tissue is mathematically characterized by the diffusion tensor, the elements of which contain information about the magnitude and direction of diffusion and is a function of the coordinate system. Thus, it is possible to generate contrast in tissue based primarily on diffusion effects. Expressing diffusion in terms of the measured diffusion coefficient (eigenvalue) in any one direction can lead to errors. Nowhere is this more evident than in white matter, due to the preferential orientation of myelin fibers. The directional dependency is removed by diagonalization of the diffusion tensor, which then yields a set of three eigenvalues and eigenvectors, representing the magnitude and direction of the three orthogonal axes of the diffusion ellipsoid, respectively. For example, the eigenvalue corresponding to the eigenvector along the long axis of the fiber corresponds qualitatively to diffusion with least restriction. Determination of the principal values of the diffusion tensor and various anisotropic indices provides structural information. We review the use of diffusion measurements using the modified Stejskal-Tanner diffusion equation. The anisotropy is analyzed by decomposing the diffusion tensor based on symmetrical properties describing the geometry of diffusion tensor. We further describe diffusion tensor properties in visualizing fiber tract organization of the human brain.

  15. Whole body diffusion for metastatic disease assessment in neuroendocrine carcinomas: comparison with OctreoScan® in two cases

    Directory of Open Access Journals (Sweden)

    Cossetti Rachel Jorge D

    2012-05-01

    Full Text Available Abstract Neuroendocrine tumor (NET patients must be adequately staged in order to improve a multidisciplinary approach and optimal management for metastatic disease. Currently available imaging studies include somatostatin receptor scintigraphy, like OctreoScan®, computed tomography (CT, scans and magnetic resonance imaging (MRI, which analyze vascular concentration and intravenous contrast enhancement for anatomic tumor localization. However, these techniques require high degree of expertise for interpretation and are limited by their availability, cost, reproducibility, and follow-up imaging comparisons. NETs significantly reduce water diffusion as compared to normal tissue. Diffusion-weighted imaging (DWI in MRI has an advantageous contrast difference: the tumor is represented with high signal over a black normal surrounding background. The whole-body diffusion (WBD technique has been suggested to be a useful test for detecting metastasis from various anatomic sites. In this article we report the use of DWI in MRI and WBD in two cases of metastatic pulmonary NET staging in comparison with OctreoScan® in order to illustrate the potential advantage of DWI and WBD in staging NETs.

  16. Digital hilar tomography. Comparison with conventional technique

    International Nuclear Information System (INIS)

    Schaefer, C.B.; Braunschweig, R.; Teufl, F.; Kaiser, W.; Claussen, C.D.

    1993-01-01

    The aim of the following study was to compare conventional hilar tomography and digital hilar tomography. 20 patients were examined both with conventional and digital hilar tomography using the same tomographic technique and the identical exposure dose. All patients underwent computed tomography of the chest as a golden standard. The digital technique, especially the edge-enhanced image version, showed superior image quality. ROC-analysis by 4 readers found equal diagnostic performance without any statistical difference. Digital hilar tomography shows a superior and constant image quality and lowers the rate of re-exposure. Therefore, digital hilar tomography is the preferable method. (orig.) [de

  17. Tomography of nonclassical states

    NARCIS (Netherlands)

    Bazrafkan, MR; Man'ko, [No Value

    2003-01-01

    A review of the symplectic tomography method is presented. Superpositions of different types of photon states are considered within the framework of the tomography approach. Such nonclassical photon states as even and odd coherent states, crystallized Schrodinger cat states, and other superposition

  18. A probability tomography approach to the analysis of potential field data in the Campi Flegrei caldera (Italy)

    Energy Technology Data Exchange (ETDEWEB)

    Iuliano, T.; Patella, D. [Naples Univ. Federico 2., Naples (Italy). Dipartimento di Scienze Fisiche; Mauriello, P. [Consiglio Nazionale delle Ricerche, Istituto per le Tecnologie Applicate ai Beni Culturali, Rome (Italy)

    2001-04-01

    The results of the application of the 3a probability tomography imaging approach to the study of the Ca mpi Fagarol (Cf) caldera are presented and discussed. The tomography approach has been applied to gravity, magnetic and ground deformation data already available in literature. The analysis of the 3a tomographic images is preceded by a brief qualitative interpretation of the original survey maps and by an outline of the probability tomography approach for each geophysical prospecting method. The results derived from the 3a tomographic images are the high occurrence probabilities of both gravity and ground deformation source centers in the Cf caldera under the town of Palazzo. A Bagger negative anomaly source centre is highlighted in the depth range 1.6-2 km b.s.l., whereas a positive ground deformation point source, responsible for the bradyseismic crisis of 1982-1984, is estimated at a mean depth of 3-4 km b.s.l. These inferences, combined with the results of a previous analysis of magnetotelluric, dipolar geolectrical and self-potential data, corroborate the hypothesis that the bradyseismic events in the CF area may be explained by hot fluids vertical advection and subsequent lateral diffusion within a trapped reservoir overlying a magma chamber.

  19. A probability tomography approach to the analysis of potential field data in the Campi Flegrei caldera (Italy

    Directory of Open Access Journals (Sweden)

    D. Patella

    2001-06-01

    Full Text Available The results of the application of the 3D probability tomography imaging approach to the study of the Campi Flegrei (CF caldera are presented and discussed. The tomography approach has been applied to gravity, magnetic and ground deformation data already available in literature. The analysis of the 3D tomographic images is preceded by a brief qualitative interpretation of the original survey maps and by an outline of the probability tomography approach for each geophysical prospecting method. The results derived from the 3D tomographic images are the high occurrence probabilities of both gravity and ground deformation source centres in the CF caldera under the town of Pozzuoli. A Bouguer negative anomaly source centre is highlighted in the depth range 1.6-2 km b.s.l., whereas a positive ground deformation point source, responsible for the bradyseismic crisis of 1982-1984, is estimated at a mean depth of 3-4 km b.s.l. These inferences, combined with the results of a previous analysis of magnetotelluric, dipolar geoelectrical and self-potential data, corroborate the hypothesis that the bradyseismic events in the CF area may be explained by hot fluids vertical advection and subsequent lateral diffusion within a trapped reservoir overlying a magma chamber.

  20. [Fluorescein angiography and optical coherence tomography findings in central fundus of myopic patients].

    Science.gov (United States)

    Avetisov, S E; Budzinskaya, M V; Zhabina, O A; Andreeva, I V; Plyukhova, A A; Kobzova, M V; Musaeva, G M

    2015-01-01

    Myopia prevalence grows alike in many countries, including Russia, regardless of geographical and population conditions. to assess fundus changes in myopic patients at different ocular axial lengths by means of modern diagnostic tools. The study enrolled 97 patients (194 eyes) aged 45 ± 20.17 years with myopia of different degrees. Besides a standard ophthalmic examination, all patients underwent fundus fluorescein angiography and optical coherence tomography. The occurrence of retinal pigment epithelium (RPE) atrophy (diffuse or focal) has been shown to increase with increasing ocular axial length. Only 27 eyes (28.1%) appeared intact. As myopia progression implies axial growth of the eye, it is associated with a more severe decrease in choroid, RPE, and photoreceptor layer thicknesses: the longer the anterior-posterior axis, the thinner the above mentioned fundus structures. Age-related changes in the fundus are also likely to be more pronounced in longer axes. Myopic traction maculopathy, which in our case appeared the main cause of increased retinal thickness, was diagnosed in 105 eyes, "outer" macular retinoschisis--in 40 eyes. Thus, modern diagnostic tools, such as fluorescein angiography and optical coherence tomography, enable objective assessment of the central fundus.

  1. ¹⁸F-fluorodeoxyglucose positron emission tomography-computed tomography for the evaluation of bone metastasis in patients with gastric cancer.

    Science.gov (United States)

    Ma, Dae Won; Kim, Jie-Hyun; Jeon, Tae Joo; Lee, Yong Chan; Yun, Mijin; Youn, Young Hoon; Park, Hyojin; Lee, Sang In

    2013-09-01

    The roles of positron emission tomography and bone scanning in identifying bone metastasis in gastric cancer are unclear. We compared the usefulness of positron emission tomography-computed tomography and scanning in detecting bone metastasis in gastric cancer. Data from 1485 patients diagnosed with gastric cancer who had undergone positron emission tomography-computed tomography and scanning were reviewed. Of 170 enrolled patients who were suspected of bone metastasis in either positron emission tomography or scanning, 81.2% were confirmed to have bone metastasis. The sensitivity, specificity, and accuracy were 93.5%, 25.0%, and 80.6%, respectively, for positron emission tomography and 93.5%, 37.5%, and 82.9%, respectively, for scanning. 87.7% of patients with bone metastasis showed positive findings on two modalities. 15.0% of solitary bone metastases were positive on positron emission tomography only. Positron emission tomography was superior to scanning for the detection of synchronous bone metastasis, but the two modalities were similar for the detection of metachronous bone metastasis. The concordance rate of response assessment after treatment between two modalities was moderate. Positron emission tomography-computed tomography may be more effective for the diagnosis of bone metastasis in the initial staging workup. Conversely, bone scanning and positron emission tomography-computed tomography may be similarly effective for the detection of metachronous bone metastasis. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  2. Comparative evaluations of the results of common X-ray examinations and computerized tomography in patients with exogenous allergic alveolitis

    International Nuclear Information System (INIS)

    Khomenko, A.G.; Dmitrieva, L.I.; Khikkel', Kh.G.; Myuller, S.

    1989-01-01

    A correlative study of the results of x-ray examination using routine methods and computerized tomography (CT) was conducted to specify the roentgenomorphological substrate of changes in patients with exogenous allergic alveolitis. The established complex of routine methods is informative enough to interpret the revealed changes. However, at early stages CT helps to specify semiotics and permits obtaining additional information, particularly on quantitative, i.e. densitometric changes. In diffuse and disseminated pulmonary lesions CT can be used as an additional method

  3. Study on Sintering Mechanism of Stainless Steel Fiber Felts by X-ray Computed Tomography

    Directory of Open Access Journals (Sweden)

    Jun Ma

    2016-01-01

    Full Text Available The microstructure evolution of Fe-17 wt. % Cr-12 wt. % Ni-2 wt. % Mo stainless steel fiber felts during the fast sintering process was investigated by the synchrotron radiation X-ray computed tomography technique. The equation of dynamics of stable inter-fiber neck growth was established for the first time based on the geometry model of sintering joints of two fibers and Kucsynski’s two-sphere model. The specific evolutions of different kinds of sintering joints were observed in the three-dimensional images. The sintering mechanisms during sintering were proposed as plastic flow and grain boundary diffusion, the former leading to a quick growth of sintering joints.

  4. Quantification in emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-11-01

    The objective of this lecture is to understand the possibilities and limitations of the quantitative analysis of single photon emission computed tomography (SPECT) and positron emission tomography (PET) images. It is also to identify the conditions to be fulfilled to obtain reliable quantitative measurements from images. Content: 1 - Introduction: Quantification in emission tomography - definition and challenges; quantification biasing phenomena 2 - Main problems impacting quantification in PET and SPECT: problems, consequences, correction methods, results (Attenuation, scattering, partial volume effect, movement, un-stationary spatial resolution in SPECT, fortuitous coincidences in PET, standardisation in PET); 3 - Synthesis: accessible efficiency, know-how, Precautions, beyond the activity measurement

  5. Fundus Autofluorescence and Optical Coherence Tomography Findings in Branch Retinal Vein Occlusion

    Directory of Open Access Journals (Sweden)

    Tetsuju Sekiryu

    2012-01-01

    Full Text Available Purpose. To describe the findings of fundus autofluorescence (FAF and optical coherence tomography (OCT in patients with branch retinal vein occlusion (BRVO. Methods. In this institutional, retrospective, observational case series, FAF was evaluated in 65 eyes with BRVO in 64 consecutive patients and compared with visual acuity, OCT findings, and other clinical observations. Results. Five types of autofluorescence appeared during the course of BRVO: (1 petaloid-shaped hyperautofluorescence in the area of macular edema and (2 hyperautofluorescence coincident with yellow subretinal deposits. (3 Diffuse hyperautofluorescence appeared within the area of serous retinal detachment (SRD and OCT showed precipitates on the undersurface of the retina in 5/5 of these eyes (100%. (4 The area of vein occlusion showed diffuse hyperautofluorescence after resolution of the retinal bleeding. (5 Hard exudates exhibited hyper- or hypoautofluorescence. OCT indicated that most of the hard exudates with hyperautofluorescence were located on the retinal pigment epithelium. Conclusions. Hyperautofluorescence associated with subretinal fluid or hard exudate appeared in the subretinal space. This type of hyperautofluorescence may be attributed to blood cell or macrophages. FAF and OCT are noninvasive modalities that provide additional information regarding macular edema due to BRVO.

  6. Regularized iterative integration combined with non-linear diffusion filtering for phase-contrast x-ray computed tomography.

    Science.gov (United States)

    Burger, Karin; Koehler, Thomas; Chabior, Michael; Allner, Sebastian; Marschner, Mathias; Fehringer, Andreas; Willner, Marian; Pfeiffer, Franz; Noël, Peter

    2014-12-29

    Phase-contrast x-ray computed tomography has a high potential to become clinically implemented because of its complementarity to conventional absorption-contrast.In this study, we investigate noise-reducing but resolution-preserving analytical reconstruction methods to improve differential phase-contrast imaging. We apply the non-linear Perona-Malik filter on phase-contrast data prior or post filtered backprojected reconstruction. Secondly, the Hilbert kernel is replaced by regularized iterative integration followed by ramp filtered backprojection as used for absorption-contrast imaging. Combining the Perona-Malik filter with this integration algorithm allows to successfully reveal relevant sample features, quantitatively confirmed by significantly increased structural similarity indices and contrast-to-noise ratios. With this concept, phase-contrast imaging can be performed at considerably lower dose.

  7. Correlated diffusion imaging

    International Nuclear Information System (INIS)

    Wong, Alexander; Glaister, Jeffrey; Cameron, Andrew; Haider, Masoom

    2013-01-01

    Prostate cancer is one of the leading causes of cancer death in the male population. Fortunately, the prognosis is excellent if detected at an early stage. Hence, the detection and localization of prostate cancer is crucial for diagnosis, as well as treatment via targeted focal therapy. New imaging techniques can potentially be invaluable tools for improving prostate cancer detection and localization. In this study, we introduce a new form of diffusion magnetic resonance imaging called correlated diffusion imaging, where the tissue being imaged is characterized by the joint correlation of diffusion signal attenuation across multiple gradient pulse strengths and timings. By taking into account signal attenuation at different water diffusion motion sensitivities, correlated diffusion imaging can provide improved delineation between cancerous tissue and healthy tissue when compared to existing diffusion imaging modalities. Quantitative evaluation using receiver operating characteristic (ROC) curve analysis, tissue class separability analysis, and visual assessment by an expert radiologist were performed to study correlated diffusion imaging for the task of prostate cancer diagnosis. These results are compared with that obtained using T2-weighted imaging and standard diffusion imaging (via the apparent diffusion coefficient (ADC)). Experimental results suggest that correlated diffusion imaging provide improved delineation between healthy and cancerous tissue and may have potential as a diagnostic tool for cancer detection and localization in the prostate gland. A new form of diffusion magnetic resonance imaging called correlated diffusion imaging (CDI) was developed for the purpose of aiding radiologists in cancer detection and localization in the prostate gland. Preliminary results show CDI shows considerable promise as a diagnostic aid for radiologists in the detection and localization of prostate cancer

  8. Xanthogranulomatous pyelonephritis in adults: clinical and radiological findings in diffuse and focal forms

    International Nuclear Information System (INIS)

    Loffroy, R.; Guiu, B.; Watfa, J.; Michel, F.; Cercueil, J.P.; Krause, D.

    2007-01-01

    Aim: To describe the clinical and radiological features of focal and diffuse xanthogranulomatous pyelonephritis (XGP) in adults. Materials and methods: A retrospective review of the clinical data, laboratory findings, imaging features, and surgical treatment of 13 cases of histologically proven XGP diagnosed between January 1993 and December 2005 was undertaken. There were 10 women and three men with a mean age of 55.2 years (range 30-87 years). All patients underwent both sonography and computed tomography (CT) of the kidneys. Magnetic resonance imaging (MRI) was performed in two patients. Results: XGP was diffuse in 11 patients and focal in two patients. Fever, anorexia and weight loss, urinary symptoms, and flank pain were the most common manifestations. Urinary tract infection was found in eight patients. Sonography and CT showed diffuse kidney enlargement in seven cases and atrophy in five cases; a solitary solid mass was found in two patients. Hydronephrosis was noted in nine cases, staghorn calculus in six, and extensive pararenal disease in six. MRI failed to provide the preoperative diagnosis in the two patients with focal XGP. Total or partial nephrectomy was performed without postoperative complications. Conclusion: Although rare, XGP is the main differential diagnosis of malignant renal neoplasia. The definitive diagnosis depends on histological examination of the operative specimen. Preoperatively, the diagnosis can often be suspected based on imaging studies, primarily CT

  9. Xanthogranulomatous pyelonephritis in adults: clinical and radiological findings in diffuse and focal forms

    Energy Technology Data Exchange (ETDEWEB)

    Loffroy, R. [Department of Radiology, Bocage Hospital, University Hospital Center, Dijon (France)]. E-mail: loffroy.romaric@neuf.fr; Guiu, B. [Department of Radiology, Bocage Hospital, University Hospital Center, Dijon (France); Watfa, J. [Department of Urology, Bocage Hospital, University Hospital Center, Dijon (France); Michel, F. [Department of Urology, Bocage Hospital, University Hospital Center, Dijon (France); Cercueil, J.P. [Department of Radiology, Bocage Hospital, University Hospital Center, Dijon (France); Krause, D. [Department of Radiology, Bocage Hospital, University Hospital Center, Dijon (France)

    2007-09-15

    Aim: To describe the clinical and radiological features of focal and diffuse xanthogranulomatous pyelonephritis (XGP) in adults. Materials and methods: A retrospective review of the clinical data, laboratory findings, imaging features, and surgical treatment of 13 cases of histologically proven XGP diagnosed between January 1993 and December 2005 was undertaken. There were 10 women and three men with a mean age of 55.2 years (range 30-87 years). All patients underwent both sonography and computed tomography (CT) of the kidneys. Magnetic resonance imaging (MRI) was performed in two patients. Results: XGP was diffuse in 11 patients and focal in two patients. Fever, anorexia and weight loss, urinary symptoms, and flank pain were the most common manifestations. Urinary tract infection was found in eight patients. Sonography and CT showed diffuse kidney enlargement in seven cases and atrophy in five cases; a solitary solid mass was found in two patients. Hydronephrosis was noted in nine cases, staghorn calculus in six, and extensive pararenal disease in six. MRI failed to provide the preoperative diagnosis in the two patients with focal XGP. Total or partial nephrectomy was performed without postoperative complications. Conclusion: Although rare, XGP is the main differential diagnosis of malignant renal neoplasia. The definitive diagnosis depends on histological examination of the operative specimen. Preoperatively, the diagnosis can often be suspected based on imaging studies, primarily CT.

  10. Tomography

    International Nuclear Information System (INIS)

    Allan, C.J.; Keller, N.A.; Lupton, L.R.; Taylor, T.; Tonner, P.D.

    1984-10-01

    Tomography is a non-intrusive imaging technique being developed at CRNL as an industrial tool for generating quantitative cross-sectional density maps of objects. Of most interest is tomography's ability to: distinguish features within complex geometries where other NDT techniques fail because of the complexity of the geometry; detect/locate small density changes/defects within objects, e.g. void fraction measurements within thick-walled vessels, shrink cavities in castings, etc.; provide quantitative data that can be used in analyses, e.g. of complex processes, or fracture mechanics; and provide objective quantitative data that can be used for (computer-based) quality assurance decisions, thereby reducing and in some cases eliminating the present subjectivity often encountered in NDT. The CRNL program is reviewed and examples are presented to illustrate the potential and the limitations of the technology

  11. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using 18 F-fluorodeoxyglucose positron emission tomography-computed tomography

    International Nuclear Information System (INIS)

    Kimizuka, Yoshifumi; Hasegawa, Naoki; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko

    2013-01-01

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess

  12. Diffusion in membranes: Toward a two-dimensional diffusion map

    Directory of Open Access Journals (Sweden)

    Toppozini Laura

    2015-01-01

    Full Text Available For decades, quasi-elastic neutron scattering has been the prime tool for studying molecular diffusion in membranes over relevant nanometer distances. These experiments are essential to our current understanding of molecular dynamics of lipids, proteins and membrane-active molecules. Recently, we presented experimental evidence from X-ray diffraction and quasi-elastic neutron scattering demonstrating that ethanol enhances the permeability of membranes. At the QENS 2014/WINS 2014 conference we presented a novel technique to measure diffusion across membranes employing 2-dimensional quasi-elastic neutron scattering. We present results from our preliminary analysis of an experiment on the cold neutron multi-chopper spectrometer LET at ISIS, where we studied the self-diffusion of water molecules along lipid membranes and have the possibility of studying the diffusion in membranes. By preparing highly oriented membrane stacks and aligning them horizontally in the spectrometer, our aim is to distinguish between lateral and transmembrane diffusion. Diffusion may also be measured at different locations in the membranes, such as the water layer and the hydrocarbon membrane core. With a complete analysis of the data, 2-dimensional mapping will enable us to determine diffusion channels of water and ethanol molecules to quantitatively determine nanoscale membrane permeability.

  13. The value of positron emission tomography/computed tomography for evaluating metastatic disease in patients with pancreatic cancer.

    Science.gov (United States)

    Kim, Mi-Jin; Lee, Kwang Hyuck; Lee, Kyu Taek; Lee, Jong Kyun; Ku, Bon-Ho; Oh, Cho-Rong; Heo, Jin Seok; Choi, Seong-Ho; Choi, Dong Wook

    2012-08-01

    Routine application of positron emission tomography/computed tomography (PET/CT) for pancreatic cancer staging remains a controversial approach. The purpose of this study was to reassess the clinical impact of PET/CT for the detection of distant metastasis of pancreatic cancer. From January 2006 to June 2009, 125 patients with histologically proven pancreatic cancer that had undergone PET/CT at our hospital were retrospectively reviewed. To evaluate the clinical efficacy of PET/CT on the management plan, the post-PET/CT management plans were compared with the pre-PET/CT management plans. After the conventional staging workup, we determined that 76 patients (60.8%) had resectable lesions, whereas 48 patients had unresectable lesions. One patient underwent explorative laparotomy due to equivocal resectability. Positron emission tomography/computed tomography diagnosed distant metastasis in only 2 (2.6%) of the 76 patients with resectable lesions, and these patients did not undergo unnecessary surgical treatment. Complete resection was not performed in 8 of the 74 operative patients because they had distant metastasis detected during the operative procedure. Positron emission tomography/computed tomography diagnosed distant metastasis in 32 of the 44 patients with metastatic lesions that were histologically shown to have sensitivity of 72.7%. Positron emission tomography/computed tomography has a limited role in the evaluation of metastatic disease from pancreatic cancer.

  14. SOUND FIELD DIFFUSIVITY AT THE TOP SURFACE OF SCHROEDER DIFFUSER BARRIERS

    Directory of Open Access Journals (Sweden)

    M. R. Monazzam

    2006-10-01

    Full Text Available Reactive barriers are one of the most promising and novel environmental noise barriers. In this case using Schroeder diffusers (e.g. quadratic residue diffusers on the top surface of the T-shape barrier was shown to significantly improve the performance of absorbent T-shape barriers. The reasons behind the high performance of diffuser barriers are considered in this investigation. A question about the diffusivity behavior of Schroeder diffusers when they are utilized on the top of barrier was raised. Diffusion coefficients of a diffuser in different conditions at some receiver locations were predicted by using a 2D boundary element method. It was found that the diffusion coefficient of diffuser at the top of barrier is so small that the diffusivity of the structure is almost the same as rigid T-shape barrier. To find the barrier’s cap behavior, the total field above the top surface of profile barriers was also predicted. It was found that the lowest total energy is at the receiver side of the cap very close to the top surface,which could demonstrate the effect of top surface on absorbing the energy as wave transfers from source edge toward the receiver side of the cap. In this case the amount of minimum total energy depends on the frequency and the configuration of the top surface. A comparison between the reductions of total field at the source side of the cap with the improvements of barrier’s performance was also done. It was shown that the amount of decrease in total field compared to that of an absorbent barrier “Ref” is directly associated to the amount of improvement in the insertion loss made by the diffuser barrier compared to the “Ref” barrier in the wide area on the ground at the shadow zone. Finally it was concluded that the diffuser on the top of barrier does not act as a diffuser and a kind of similarity between the contribution of diffuser and absorbent material on the top of T-profile barrier is seen.

  15. Left ventricular rigid body rotation in a diffuse large B-cell lymphoma patient with cardiac involvement: A case from the three-dimensional speckle-tracking echocardiographic MAGYAR-Path Study.

    Science.gov (United States)

    Földeák, Dóra; Kalapos, Anita; Domsik, Péter; Sinkó, Mária; Szeleczki, Nóra; Bagdi, Enikő; Krenács, László; Forster, Tamás; Borbényi, Zita; Nemes, Attila

    2017-02-01

    Secondary myocardial involvement by diffuse large B-cell lymphoma is a rare occurrence. Left ventricular (LV) twist is considered an essential part of LV function. In normal circumstances LV twist results from the movement of two orthogonally oriented muscular bands of a helical myocardial structure with consequent clockwise rotation of the base and counterclockwise rotation of the apex. Three-dimensional (3D) speckle-tracking echocardiography (3DSTE) has been found to be feasible for non-invasive 3D quantification of LV wall motion and rotational mechanics. The present report aimed to assess LV twisting motion in a patient with diffuse large B-cell lymphoma with positron emission tomography/computer tomography-proven cardiac involvement by 3DSTE. During 3DSTE, reduction in some segmental radial, longitudinal, circumferential, area and 3D LV strains were found. Apical and basal LV rotations were found to be in the same counterclockwise direction, confirming near absence of LV twist - so-called rigid body rotation. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Role of W and Mn for reliable 1X nanometer-node ultra-large-scale integration Cu interconnects proved by atom probe tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shima, K.; Shimizu, H.; Momose, T.; Shimogaki, Y. [Department of Materials Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Tu, Y. [The Oarai Center, Institute for Materials Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Key Laboratory of Polar Materials and Devices, Ministry of Education, East China Normal University, Shanghai 200241 (China); Takamizawa, H.; Shimizu, Y.; Inoue, K.; Nagai, Y. [The Oarai Center, Institute for Materials Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan)

    2014-09-29

    We used atom probe tomography (APT) to study the use of a Cu(Mn) as a seed layer of Cu, and a Co(W) single-layer as reliable Cu diffusion barriers for future interconnects in ultra-large-scale integration. The use of Co(W) layer enhances adhesion of Cu to prevent electromigration and stress-induced voiding failures. The use of Cu(Mn) as seed layer may enhance the diffusion barrier performance of Co(W) by stuffing the Cu diffusion pass with Mn. APT was used to visualize the distribution of W and Mn in three dimensions with sub-nanometer resolution. W was found to segregate at the grain boundaries of Co, which prevents diffusion of Cu via the grain boundaries. Mn was found to diffuse from the Cu(Mn) layer to Co(W) layer and selectively segregate at the Co(W) grain boundaries with W, reinforcing the barrier properties of Co(W) layer. Hence, a Co(W) barrier coupled with a Cu(Mn) seed layer can form a sufficient diffusion barrier with film that is less than 2.0-nm-thick. The diffusion barrier behavior was preserved following a 1-h annealing at 400 °C. The underlayer of the Cu interconnects requires a large adhesion strength with the Cu, as well as low electrical resistivity. The use of Co(W) has previously been shown to satisfy these requirements, and addition of Mn is not expected to deteriorate these properties.

  17. 3.55 GeV/c Kp elastic scattering near 180 deg; Diffusion elastique des K de 3.55 GeV/C par les protons, au voisinage de 180 deg

    Energy Technology Data Exchange (ETDEWEB)

    Duflo, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    Backward elastic K{sup +}p and K{sup -}p scattering has been measured in the angular interval 168 deg. < {theta}.c.m. < 177 deg. The experimental apparatus included optical spark chambers to measure the three prongs of the event scattering, a set of scintillation counters and Cerenkov counters to select events ant trigger chambers, and a magnet to determine the moment of the recoil proton. 106000 photographs was taken. Of these, 22 satisfied all requirements as elastic K{sup +}p scattering events. No event was found satisfy the kinematical criteria for K{sup -}p elastic scattering. The correspondent values of differential cross sections are: (d{sigma}/d{omega})K{sup +}p {yields} pK{sup +} = 17 {+-} 4 {mu}b/ster. (d{sigma}/d{omega})K{sup -}p {yields} pK{sup -} {<=} 0.6 {mu}b/ster. Contaminations by {pi}p backward scattering, and inelastic scattering were estimated. Elastic scattering K{sup +}p exhibits a backward peak. A reasonably satisfactory interpretation of our results is obtained by exchange models. There is, in fact, no definitely established particles which could intermediate the Kp{sup -} {yields} pK{sup -} process in exchange cannel. That is in good agreement with our small value of K{sup -}p backward elastic scattering cross section. Our results lend support to the conclusions of the interference model developed by Barger and Cline for the {pi}p backward scattering, and to qualitative previsions of the Quark models. (author) [French] La diffusion elastique en arriere des K{sup +} et K{sup -} par les protons a ete mesuree dans l'intervalle angulaire 168 deg. < {theta}cm < 177 deg. Le dispositif experimental comprenait des chambres a etincelles 'optiques' pour mesurer les trois trajectoires de l'evenement diffuse, un ensemble de compteurs a scintillations et de compteurs Cerenkov pour selectionner les evenements et declencher les chambres, et un aimant pour determiner le moment du proton de recul. 106000 photographies ont ete prises, dont 22 ont satisfait a

  18. 3.55 GeV/c Kp elastic scattering near 180 deg; Diffusion elastique des K de 3.55 GeV/C par les protons, au voisinage de 180 deg

    Energy Technology Data Exchange (ETDEWEB)

    Duflo, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    Backward elastic K{sup +}p and K{sup -}p scattering has been measured in the angular interval 168 deg. < {theta}.c.m. < 177 deg. The experimental apparatus included optical spark chambers to measure the three prongs of the event scattering, a set of scintillation counters and Cerenkov counters to select events ant trigger chambers, and a magnet to determine the moment of the recoil proton. 106000 photographs was taken. Of these, 22 satisfied all requirements as elastic K{sup +}p scattering events. No event was found satisfy the kinematical criteria for K{sup -}p elastic scattering. The correspondent values of differential cross sections are: (d{sigma}/d{omega})K{sup +}p {yields} pK{sup +} = 17 {+-} 4 {mu}b/ster. (d{sigma}/d{omega})K{sup -}p {yields} pK{sup -} {<=} 0.6 {mu}b/ster. Contaminations by {pi}p backward scattering, and inelastic scattering were estimated. Elastic scattering K{sup +}p exhibits a backward peak. A reasonably satisfactory interpretation of our results is obtained by exchange models. There is, in fact, no definitely established particles which could intermediate the Kp{sup -} {yields} pK{sup -} process in exchange cannel. That is in good agreement with our small value of K{sup -}p backward elastic scattering cross section. Our results lend support to the conclusions of the interference model developed by Barger and Cline for the {pi}p backward scattering, and to qualitative previsions of the Quark models. (author) [French] La diffusion elastique en arriere des K{sup +} et K{sup -} par les protons a ete mesuree dans l'intervalle angulaire 168 deg. < {theta}cm < 177 deg. Le dispositif experimental comprenait des chambres a etincelles 'optiques' pour mesurer les trois trajectoires de l'evenement diffuse, un ensemble de compteurs a scintillations et de compteurs Cerenkov pour selectionner les evenements et declencher les chambres, et un aimant pour determiner le moment du proton de recul. 106000 photographies ont ete prises

  19. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Harris, L.D.; Ritman, E.L.; Robb, R.A.

    1987-01-01

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  20. SOUND FIELD DIFFUSIVITY AT THE TOP SURFACE OF SCHROEDER DIFFUSER BARRIERS

    OpenAIRE

    M. R. Monazzam

    2006-01-01

    Reactive barriers are one of the most promising and novel environmental noise barriers. In this case using Schroeder diffusers (e.g. quadratic residue diffusers) on the top surface of the T-shape barrier was shown to significantly improve the performance of absorbent T-shape barriers. The reasons behind the high performance of diffuser barriers are considered in this investigation. A question about the diffusivity behavior of Schroeder diffusers when they are utilized on the top of barrier wa...

  1. Brain perfusion single photon emission computed tomography in children after acute encephalopathy

    International Nuclear Information System (INIS)

    Kurihara, Mana; Nakae, Yoichiro; Kohagizawa, Toshitaka; Eto, Yoshikatsu

    2005-01-01

    We studied single photon emission computed tomography (SPECT) of 15 children with acute encephalopathy after more than 1 year from the onset, using technetium-99 m-L, L-ethyl cystinate dimer ( 99m Tc-ECD) and a three-dementional stereotaxic region of interest template. Regional cerebral blood flow was evaluated and divided in three groups according to the severity of disability: absent or mild, moderate, and severe. There was no abnormality on SPECT in the patients without disability or with mild disability. Diffuse hypoperfusion was shown in the groups with moderate and severe disability. The patients with severe disability showed hypoperfusion in the pericallosal, frontal and central areas which was more pronounced than in the patients with moderate disability. (author)

  2. Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yidong, E-mail: yidongyang@med.miami.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 and Department of Radiation Oncology, University of Miami School of Medicine, Miami, Florida 33136 (United States); Wang, Ken Kang-Hsin; Wong, John W. [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 (United States); Eslami, Sohrab; Iordachita, Iulian I. [Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Patterson, Michael S. [Juravinski Cancer Centre and Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario L8S4K1 (Canada)

    2015-04-15

    Purpose: The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides excellent bone to soft tissue contrast, but is incapable of differentiating tumors from surrounding soft tissue. Bioluminescence tomography (BLT), in contrast, allows direct visualization of even subpalpable tumors and quantitative evaluation of tumor response. Integration of BLT with CBCT offers complementary image information, with CBCT delineating anatomic structures and BLT differentiating luminescent tumors. This study is to develop a systematic method to calibrate an integrated CBCT and BLT imaging system which can be adopted onboard the SARRP to guide focal tumor irradiation. Methods: The integrated imaging system consists of CBCT, diffuse optical tomography (DOT), and BLT. The anatomy acquired from CBCT and optical properties acquired from DOT serve as a priori information for the subsequent BLT reconstruction. Phantoms were designed and procedures were developed to calibrate the CBCT, DOT/BLT, and the entire integrated system. Geometrical calibration was performed to calibrate the CBCT system. Flat field correction was performed to correct the nonuniform response of the optical imaging system. Absolute emittance calibration was performed to convert the camera readout to the emittance at the phantom or animal surface, which enabled the direct reconstruction of the bioluminescence source strength. Phantom and mouse imaging were performed to validate the calibration. Results: All calibration procedures were successfully performed. Both CBCT of a thin wire and a euthanized mouse revealed no spatial artifact, validating the accuracy of the CBCT calibration. The absolute emittance calibration was validated with a 650 nm laser source, resulting in a 3

  3. Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research

    International Nuclear Information System (INIS)

    Yang, Yidong; Wang, Ken Kang-Hsin; Wong, John W.; Eslami, Sohrab; Iordachita, Iulian I.; Patterson, Michael S.

    2015-01-01

    Purpose: The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides excellent bone to soft tissue contrast, but is incapable of differentiating tumors from surrounding soft tissue. Bioluminescence tomography (BLT), in contrast, allows direct visualization of even subpalpable tumors and quantitative evaluation of tumor response. Integration of BLT with CBCT offers complementary image information, with CBCT delineating anatomic structures and BLT differentiating luminescent tumors. This study is to develop a systematic method to calibrate an integrated CBCT and BLT imaging system which can be adopted onboard the SARRP to guide focal tumor irradiation. Methods: The integrated imaging system consists of CBCT, diffuse optical tomography (DOT), and BLT. The anatomy acquired from CBCT and optical properties acquired from DOT serve as a priori information for the subsequent BLT reconstruction. Phantoms were designed and procedures were developed to calibrate the CBCT, DOT/BLT, and the entire integrated system. Geometrical calibration was performed to calibrate the CBCT system. Flat field correction was performed to correct the nonuniform response of the optical imaging system. Absolute emittance calibration was performed to convert the camera readout to the emittance at the phantom or animal surface, which enabled the direct reconstruction of the bioluminescence source strength. Phantom and mouse imaging were performed to validate the calibration. Results: All calibration procedures were successfully performed. Both CBCT of a thin wire and a euthanized mouse revealed no spatial artifact, validating the accuracy of the CBCT calibration. The absolute emittance calibration was validated with a 650 nm laser source, resulting in a 3

  4. Positron emission tomography

    International Nuclear Information System (INIS)

    Dvorak, O.

    1989-01-01

    The principle is briefly described of positron emission tomography, and its benefits and constraints are listed. It is emphasized that positron emission tomography (PET) provides valuable information on metabolic changes in the organism that are otherwise only very difficult to obtain, such as brain diagnosis including relationships between mental disorders and the physiology and pathophysiology of the brain. A PET machine is to be installed in Czechoslovakia in the near future. (L.O.)

  5. Diffusive instabilities in hyperbolic reaction-diffusion equations

    Science.gov (United States)

    Zemskov, Evgeny P.; Horsthemke, Werner

    2016-03-01

    We investigate two-variable reaction-diffusion systems of the hyperbolic type. A linear stability analysis is performed, and the conditions for diffusion-driven instabilities are derived. Two basic types of eigenvalues, real and complex, are described. Dispersion curves for both types of eigenvalues are plotted and their behavior is analyzed. The real case is related to the Turing instability, and the complex one corresponds to the wave instability. We emphasize the interesting feature that the wave instability in the hyperbolic equations occurs in two-variable systems, whereas in the parabolic case one needs three reaction-diffusion equations.

  6. Validity of apparent diffusion coefficient hyperpolarized 3He-MRI using MSCT and pulmonary function tests as references

    DEFF Research Database (Denmark)

    Diaz, Sandra; Casselbrant, Ingrid; Piitulainen, Eeva

    2008-01-01

    PURPOSE: To compare apparent diffusion coefficient (ADC) measurements from hyperpolarized (HP) helium ((3)He)-magnetic resonance imaging (MRI) with quantitative data from multislice Computed Tomography (CT) (MSCT) of the whole lungs and pulmonary function tests (PFT). MATERIALS AND METHODS: Twenty......-seven subjects, 22 with established emphysema and 5 with preclinical emphysema defined by PFT criteria, were examined with HP (3)He-MRI and MSCT. Mean age was 55 (+/-12) years, 18 female and 9 male. Mean ADC from (3)He-MRI was compared with emphysema index (EI), 15th percentile and mean lung density (MLD) values...... from MSCT. Both mean ADC and MSCT data were compared to PFT, especially percent of predicted diffusing capacity of carbon monoxide (%predicted DLCO), using Pearson's correlation test. RESULTS: Mean ADC and standard deviation values were 0.392+/-0.119 cm(2)/s for the established emphysema group and 0...

  7. Capillaries within compartments: microvascular interpretation of dynamic positron emission tomography data

    DEFF Research Database (Denmark)

    Munk, O L; Keiding, S; Bass, L

    2003-01-01

    scanners, little use is made of earlier microvascular research in the compartmental models, which have become the standard model by which the vast majority of dynamic PET data are analysed. However, modern PET scanners provide data with a sufficient temporal resolution and good counting statistics to allow...... single- and multi-capillary systems and include effects of non-exchanging vessels. They are suitable for analysing dynamic PET data from any capillary bed using either intravascular or diffusible tracers, in terms of physiological parameters which include regional blood flow. Udgivelsesdato: 2003-Nov-7......Measurement of exchange of substances between blood and tissue has been a long-lasting challenge to physiologists, and considerable theoretical and experimental accomplishments were achieved before the development of the positron emission tomography (PET). Today, when modeling data from modern PET...

  8. Quantitative x-ray dark-field computed tomography

    International Nuclear Information System (INIS)

    Bech, M; Pfeiffer, F; Bunk, O; Donath, T; David, C; Feidenhans'l, R

    2010-01-01

    The basic principles of x-ray image formation in radiology have remained essentially unchanged since Roentgen first discovered x-rays over a hundred years ago. The conventional approach relies on x-ray attenuation as the sole source of contrast and draws exclusively on ray or geometrical optics to describe and interpret image formation. Phase-contrast or coherent scatter imaging techniques, which can be understood using wave optics rather than ray optics, offer ways to augment or complement the conventional approach by incorporating the wave-optical interaction of x-rays with the specimen. With a recently developed approach based on x-ray optical gratings, advanced phase-contrast and dark-field scatter imaging modalities are now in reach for routine medical imaging and non-destructive testing applications. To quantitatively assess the new potential of particularly the grating-based dark-field imaging modality, we here introduce a mathematical formalism together with a material-dependent parameter, the so-called linear diffusion coefficient and show that this description can yield quantitative dark-field computed tomography (QDFCT) images of experimental test phantoms.

  9. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  10. Usefulness of acute myocardial infarct size and localization using Tc-99m-pyrophosphate and single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fujisue, Ryu; Ohyanagi, Mitsumasa; Todo, Yasuhiro

    1985-01-01

    Tc-99m-Pyrophosphate(PYP)myocardial emission computed tomography(ECT) was performed following standard planar imaging in 45 patients(pts) with acute myocardial infarction(AMI). All of them had clinical, electrocardiographic and enzymatic evidence of AMI. The planar imaging and ECT imaging were interpreted independently by two observers who had no knowledge of the clinical findings. 10 pts(22.2 %), who showed diffuse uptake on planar imaging, revealed focal uptake on ECT imaging without cardiac blood pool imaging. And there is no disagreement as to interpretation of the infarct location by two observers on ECT imaging. We conclude that ECT imaging with Tc-99m-PYP increases interobserver agreement in the diagnosis and localization of AMI and may lead to more accurate localization and sizing of AMI, espesically in cases of diffuse cardiac activity on planar imaging. (author)

  11. Revaluation on detection of metastatic cancer of the colorectum with barium enema. Comparison with computed tomography and colonoscopy

    International Nuclear Information System (INIS)

    Watari, Jiro; Mizukami, Yusuke; Tanabe, Hirotaka

    1996-01-01

    The findings with barium enema were analyzed and compared to those with computed tomography and colonoscopy in 15 patients with metastatic cancer of the colorectum, which were from 8 gastric, 2 colonic, 2 ovarian, 1 pancreatic, 1 prostatic carcinomas and 1 unknown origin. Primary cancers of intra-abdominal cavity origin tended to make multiple colorectal metastases (91.7%). With barium enema colonic and rectal involvement was mostly expressed as the tethered type and the diffuse type by Ishikawa's classification, respectively. Computed tomography detected direct tumor invasion to the colorectum in 4 cases. Of the other 11 cases, 8 patients (72.3%) showed abnormally thickened colorectal wall. Colonoscopy detected only 3 (37.5%) out of 8 lesions seen in 4 patients who had undergone colonoscopy before barium enema. Many of the lesions missed were the tethered type involvement. Barium enema is the most sensitive method to detect metastatic cancer of the colorectum. (author)

  12. The Pearson diffusions: A class of statistically tractable diffusion processes

    DEFF Research Database (Denmark)

    Forman, Julie Lyng; Sørensen, Michael

    The Pearson diffusions is a flexible class of diffusions defined by having linear drift and quadratic squared diffusion coefficient. It is demonstrated that for this class explicit statistical inference is feasible. Explicit optimal martingale estimating func- tions are found, and the corresponding...

  13. Fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of residual intramuscular myxoma

    International Nuclear Information System (INIS)

    Zade, Anand; Ahire, Archana; Shetty, Shishir; Rai, Sujith; Bokka, Rajashekharrao; Velumani, Arokiaswamy; Kabnurkar, Rasika

    2015-01-01

    Intramuscular myxoma (IM) is a rare benign neoplasm. In a patient diagnosed with IM of left thigh, we report the utility of a postoperative fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography scan in assessing the efficacy of surgical excision

  14. Diffusion tensor imaging correlates with lesion volume in cerebral hemisphere infarctions

    International Nuclear Information System (INIS)

    Rossi, Maija E; Jason, Eeva; Marchesotti, Silvia; Dastidar, Prasun; Ollikainen, Jyrki; Soimakallio, Seppo

    2010-01-01

    Both a large lesion volume and abnormalities in diffusion tensor imaging are independently associated with a poor prognosis after cerebral infarctions. Therefore, we assume that they are associated. This study assessed the associations between lesion volumes and diffusion tensor imaging in patients with a right-sided cerebral infarction. The lesion volumes of 33 patients (age 65.9 ± 8.7, 26 males and 7 females) were imaged using computed tomography (CT) in the acute phase (within 3-4 hours) and magnetic resonance imaging (MRI) in the chronic phase (follow-up at 12 months, with a range of 8-27 months). The chronic-phase fractional anisotropy (FA) and mean diffusivity (MD) values were measured at the site of the infarct and selected white matter tracts. Neurological tests in both the acute and chronic phases, and DTI lateralization were assessed with the Wilcoxon signed-rank test. The effects of thrombolytic therapy (n = 10) were assessed with the Mann-Whitney U test. The correlations between the measured parameters were analysed with Spearman's rho correlation. Bonferroni post-hoc correction was used to compensate for the familywise error rate in multiple comparisons. Several MD values in the right hemisphere correlated positively and FA values negatively with the lesion volumes. These correlations included both lesion area and healthy tissue. The results of the mini-mental state examination and the National Institutes of Health Stroke Scale also correlated with the lesion volume. A larger infarct volume is associated with more pronounced tissue modifications in the chronic stage as observed with the MD and FA alterations

  15. Résultats de recherche | Page 10 | CRDI - Centre de recherches ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    MERCOSUR : recherche et intégration économiques - phase IV. Le Red Mercosur de Investigaciones Económicas (Red Mercosur) a été créé en 1998 à la suite d'un projet subventionné par le CRDI visant à fournir un mécanisme de soutien technique et une « optique régionale » (à la différence des optiques nati. Projet ...

  16. Resistivity tomography-basic concepts and its application. Hiteiko tomography no kiso to oyo

    Energy Technology Data Exchange (ETDEWEB)

    Shima, H

    1990-12-31

    In this paper, principles and characteristics of resistivity tomography are outlined, and its application examples are described. Resistivity tomography is a technology to measure electric potential of many electrodes placed on the earth {prime} s surface or in the well and to analyze the resistivity distribution in the objective area. Arrangement of electrodes (current electrodes and potential electrodes) is determined taking account of the sensitivity distribution. Also, measurements need to be done not only between the surface and a borehole and between boreholes, but also along the wall of a borehole. After the measured data are corrected according to the influence of topography, the initial model is revised repeatedly with the Alpha Center method, and then, resistivity distribution maps are obtained. As an example of field application of resistivity tomography, a geological survey using three boreholes at the scheduled construction site for a dam is described. In this survey, distribution conditions of surface soil, gravel, and andesite were confirmed, and the results almost agreed with the results of seismic tomography. Moreover, another survey with resistivity tomography was carried out at the test site of hot dry rock power generation in Yamagata Prefecture. There, conductive solution was injected from the borehole after hydraulic fracturing, and cracking conditions of rocks were investigated. 28 refs., 21 figs., 1 tab.

  17. Computed tomography imaging of early coronary artery lesions in stable individuals with multiple cardiovascular risk factors

    Directory of Open Access Journals (Sweden)

    Xi Yang

    2015-04-01

    Full Text Available OBJECTIVES: To investigate the prevalence, extent, severity, and features of coronary artery lesions in stable patients with multiple cardiovascular risk factors. METHODS: Seventy-seven patients with more than 3 cardiovascular risk factors were suspected of having coronary artery disease. Patients with high-risk factors and 39 controls with no risk factors were enrolled in the study. The related risk factors included hypertension, impaired glucose tolerance, dyslipidemia, smoking history, and overweight. The characteristics of coronary lesions were identified and evaluated by 64-slice coronary computed tomography angiography. RESULTS: The incidence of coronary atherosclerosis was higher in the high-risk group than in the no-risk group. The involved branches of the coronary artery, the diffusivity of the lesion, the degree of stenosis, and the nature of the plaques were significantly more severe in the high-risk group compared with the no-risk group (all p < 0.05. CONCLUSION: Among stable individuals with high-risk factors, early coronary artery lesions are common and severe. Computed tomography has promising value for the early screening of coronary lesions.

  18. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using (18) F-fluorodeoxyglucose positron emission tomography-computed tomography.

    Science.gov (United States)

    Kimizuka, Yoshifumi; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko; Hasegawa, Naoki

    2013-11-14

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess.

  19. The magnetic diffusion of neutrons; La diffusion magnetique des neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, W C [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    The purpose of this report is to examine briefly the diffusion of neutrons by substances, particularly by crystals containing permanent atomic or ionic magnetic moments. In other words we shall deal with ferromagnetic, antiferromagnetic, ferrimagnetic or paramagnetic crystals, but first it is necessary to touch on nuclear diffusion of neutrons. We shall start with the interaction of the neutron with a single diffusion centre; the results will then be applied to the magnetic interactions of the neutron with the satellite electrons of the atom; finally we shall discuss the diffusion of neutrons by crystals. (author) [French] Le but de ce rapport est d'examiner, brievement, la diffusion des neutrons par les substances, et surtout, par des cristaux qui contiennent des moments magnetiques atomiques ou ioniques permanents. C'est-a-dire que nous nous interesserons aux cristaux ferromagnetiques, antiferromagnetiques, ferrimagnetiques ou paramagnetiques; il nous faut cependant rappeler d'abord la diffusion nucleaire des neutrons. Nous commencerons par l'interaction du neutron avec un seul centre diffuseur; puis les resultats seront appliques aux interactions magnetiques du neutron avec les electrons satellites de l'atome; enfin nous discuterons la diffusion des neutrons par les cristaux. (auteur)

  20. Diagnosis of Lumbar Foraminal Stenosis using Diffusion Tensor Imaging.

    Science.gov (United States)

    Eguchi, Yawara; Ohtori, Seiji; Suzuki, Munetaka; Oikawa, Yasuhiro; Yamanaka, Hajime; Tamai, Hiroshi; Kobayashi, Tatsuya; Orita, Sumihisa; Yamauchi, Kazuyo; Suzuki, Miyako; Aoki, Yasuchika; Watanabe, Atsuya; Kanamoto, Hirohito; Takahashi, Kazuhisa

    2016-02-01

    Diagnosis of lumbar foraminal stenosis remains difficult. Here, we report on a case in which bilateral lumbar foraminal stenosis was difficult to diagnose, and in which diffusion tensor imaging (DTI) was useful. The patient was a 52-year-old woman with low back pain and pain in both legs that was dominant on the right. Right lumbosacral nerve compression due to a massive uterine myoma was apparent, but the leg pain continued after a myomectomy was performed. No abnormalities were observed during nerve conduction studies. Computed tomography and magnetic resonance imaging indicated bilateral L5 lumbar foraminal stenosis. DTI imaging was done. The extraforaminal values were decreased and tractography was interrupted in the foraminal region. Bilateral L5 vertebral foraminal stenosis was treated by transforaminal lumbar interbody fusion and the pain in both legs disappeared. The case indicates the value of DTI for diagnosing vertebral foraminal stenosis.

  1. Simulation of anisotropic diffusion by means of a diffusion velocity method

    CERN Document Server

    Beaudoin, A; Rivoalen, E

    2003-01-01

    An alternative method to the Particle Strength Exchange method for solving the advection-diffusion equation in the general case of a non-isotropic and non-uniform diffusion is proposed. This method is an extension of the diffusion velocity method. It is shown that this extension is quite straightforward due to the explicit use of the diffusion flux in the expression of the diffusion velocity. This approach is used to simulate pollutant transport in groundwater and the results are compared to those of the PSE method presented in an earlier study by Zimmermann et al.

  2. Measuring Weld Profiles By Computer Tomography

    Science.gov (United States)

    Pascua, Antonio G.; Roy, Jagatjit

    1990-01-01

    Noncontacting, nondestructive computer tomography system determines internal and external contours of welded objects. System makes it unnecessary to take metallurgical sections (destructive technique) or to take silicone impressions of hidden surfaces (technique that contaminates) to inspect them. Measurements of contours via tomography performed 10 times as fast as measurements via impression molds, and tomography does not contaminate inspected parts.

  3. The role of red blood cell scintigraphy in the multiple-modality imaging diagnosis of a rare case of diffuse hepatic hemangiomatosis in an adult

    Directory of Open Access Journals (Sweden)

    Ernesto Cason

    2013-03-01

    Full Text Available Introduction: Angiomas are one of the most common primary tumors of the liver. Diffuse hepatic angiomatosis, however, is quite rare and usually observed in pediatric patients. We report a rare case of diffuse hepatic hemangiomatosis in a 33-year-old woman. Case report: The patient presented with abdominal pain and a palpable upper abdominal mass. Abdominal CT and magnetic resonance imaging (MRI findings suggested diffuse hepatic hemangiomatosis, but this finding was not confirmed by subsequent contrast-enhanced abdominal ultrasonography (US. The patient then underwent single photon emission computed tomography (SPECT/CT scintigraphy with Tc-99m-labeling of red blood cells (RBC. This examination revealed increased uptake of labeled erythrocytes in several of the hepatic lesions corresponding to CT and RM findings, thereby confirming the clinical hypothesis of diffuse hepatic hemangiomatosis. Discussion: RBC scintigraphy with SPECT/CT can facilitate the comparison of other crosssectional imaging methods such as CT and MRI. This case highlights the importance of a multiple-modality approach in the imaging diagnosis of this condition.

  4. Diffusion in reactor materials

    International Nuclear Information System (INIS)

    Fedorov, G.B.; Smirnov, E.A.

    1984-01-01

    The monograph contains a brief description of the principles underlying the theory of diffusion, as well as modern methods of studying diffusion. Data on self-diffusion and diffusion of impurities in a nuclear fuel and fissionable materials (uranium, plutonium, thorium, zirconium, titanium, hafnium, niobium, molybdenum, tungsten, beryllium, etc.) is presented. Anomalous diffusion, diffusion of components, and interdiffusion in binary and ternary alloys were examined. The monograph presents the most recent reference material on diffusion. It is intended for a wide range of researchers working in the field of diffusion in metals and alloys and attempting to discover new materials for application in nuclear engineering. It will also be useful for teachers, research scholars and students of physical metallurgy

  5. Self-diffusion in isotopically enriched silicon carbide and its correlation with dopant diffusion

    International Nuclear Information System (INIS)

    Rueschenschmidt, K.; Bracht, H.; Stolwijk, N.A.; Laube, M.; Pensl, G.; Brandes, G.R.

    2004-01-01

    Diffusion of 13 C and 30 Si in silicon carbide was performed with isotopically enriched 4H- 28 Si 12 C/ nat SiC heterostructures which were grown by chemical vapor phase epitaxy. After diffusion annealing at temperatures between 2000 deg. C and 2200 deg. C the 30 Si and 13 C profiles were measured by means of secondary ion mass spectrometry. We found that the Si and C diffusivity is of the same order of magnitude but several orders of magnitude lower than earlier data reported in the literature. Both Si and C tracer diffusion coefficients are in satisfactory agreement with the native point defect contribution to self-diffusion deduced from B diffusion in SiC. This reveals that the native defect which mediates B diffusion also controls self-diffusion. Assuming that B atoms within the extended tail region of B profiles are mainly dissolved on C sites, we propose that B diffuses via the kick-out mechanism involving C interstitials. Accordingly, C diffusion should proceed mainly via C interstitials. The mechanism of Si diffusion remains unsolved but Si may diffuse via both Si vacancies and interstitials, with the preference for either species depending on the doping level

  6. Fractal diffusion equations: Microscopic models with anomalous diffusion and its generalizations

    International Nuclear Information System (INIS)

    Arkhincheev, V.E.

    2001-04-01

    To describe the ''anomalous'' diffusion the generalized diffusion equations of fractal order are deduced from microscopic models with anomalous diffusion as Comb model and Levy flights. It is shown that two types of equations are possible: with fractional temporal and fractional spatial derivatives. The solutions of these equations are obtained and the physical sense of these fractional equations is discussed. The relation between diffusion and conductivity is studied and the well-known Einstein relation is generalized for the anomalous diffusion case. It is shown that for Levy flight diffusion the Ohm's law is not applied and the current depends on electric field in a nonlinear way due to the anomalous character of Levy flights. The results of numerical simulations, which confirmed this conclusion, are also presented. (author)

  7. Hyperspectral optical tomography of intrinsic signals in the rat cortex

    Science.gov (United States)

    Konecky, Soren D.; Wilson, Robert H.; Hagen, Nathan; Mazhar, Amaan; Tkaczyk, Tomasz S.; Frostig, Ron D.; Tromberg, Bruce J.

    2015-01-01

    Abstract. We introduce a tomographic approach for three-dimensional imaging of evoked hemodynamic activity, using broadband illumination and diffuse optical tomography (DOT) image reconstruction. Changes in diffuse reflectance in the rat somatosensory cortex due to stimulation of a single whisker were imaged at a frame rate of 5 Hz using a hyperspectral image mapping spectrometer. In each frame, images in 38 wavelength bands from 484 to 652 nm were acquired simultaneously. For data analysis, we developed a hyperspectral DOT algorithm that used the Rytov approximation to quantify changes in tissue concentration of oxyhemoglobin (ctHbO2) and deoxyhemoglobin (ctHb) in three dimensions. Using this algorithm, the maximum changes in ctHbO2 and ctHb were found to occur at 0.29±0.02 and 0.66±0.04  mm beneath the surface of the cortex, respectively. Rytov tomographic reconstructions revealed maximal spatially localized increases and decreases in ctHbO2 and ctHb of 321±53 and 555±96  nM, respectively, with these maximum changes occurring at 4±0.2  s poststimulus. The localized optical signals from the Rytov approximation were greater than those from modified Beer–Lambert, likely due in part to the inability of planar reflectance to account for partial volume effects. PMID:26835483

  8. Positron emission tomography/computed tomography surveillance in patients with Hodgkin lymphoma in first remission has a low positive predictive value and high costs.

    Science.gov (United States)

    El-Galaly, Tarec Christoffer; Mylam, Karen Juul; Brown, Peter; Specht, Lena; Christiansen, Ilse; Munksgaard, Lars; Johnsen, Hans Erik; Loft, Annika; Bukh, Anne; Iyer, Victor; Nielsen, Anne Lerberg; Hutchings, Martin

    2012-06-01

    The value of performing post-therapy routine surveillance imaging in patients with Hodgkin lymphoma is controversial. This study evaluates the utility of positron emission tomography/computed tomography using 2-[18F]fluoro-2-deoxyglucose for this purpose and in situations with suspected lymphoma relapse. We conducted a multicenter retrospective study. Patients with newly diagnosed Hodgkin lymphoma achieving at least a partial remission on first-line therapy were eligible if they received positron emission tomography/computed tomography surveillance during follow-up. Two types of imaging surveillance were analyzed: "routine" when patients showed no signs of relapse at referral to positron emission tomography/computed tomography, and "clinically indicated" when recurrence was suspected. A total of 211 routine and 88 clinically indicated positron emission tomography/computed tomography studies were performed in 161 patients. In ten of 22 patients with recurrence of Hodgkin lymphoma, routine imaging surveillance was the primary tool for the diagnosis of the relapse. Extranodal disease, interim positron emission tomography-positive lesions and positron emission tomography activity at response evaluation were all associated with a positron emission tomography/computed tomography-diagnosed preclinical relapse. The true positive rates of routine and clinically indicated imaging were 5% and 13%, respectively (P = 0.02). The overall positive predictive value and negative predictive value of positron emission tomography/computed tomography were 28% and 100%, respectively. The estimated cost per routine imaging diagnosed relapse was US$ 50,778. Negative positron emission tomography/computed tomography reliably rules out a relapse. The high false positive rate is, however, an important limitation and a confirmatory biopsy is mandatory for the diagnosis of a relapse. With no proven survival benefit for patients with a pre-clinically diagnosed relapse, the high costs and low

  9. Diffusion in molybdenum disilicide

    International Nuclear Information System (INIS)

    Salamon, M.; Mehrer, H.

    2005-01-01

    The diffusion behaviour of the high-temperature material molybdenum disilicide (MoSi 2 ) was completely unknown until recently. In this paper we present studies of Mo self-diffusion and compare our present results with our already published studies of Si and Ge diffusion in MoSi 2 . Self-diffusion of molybdenum in monocrystalline MoSi 2 was studied by the radiotracer technique using the radioisotope 99 Mo. Deposition of the radiotracer and serial sectioning after the diffusion anneals to determine the concentration-depth profiles was performed using a sputtering device. Diffusion of Mo is a very slow process. In the entire temperature region investigated (1437 to 2173 K), the 99 Mo diffusivities in both principal directions of the tetragonal MoSi 2 crystals obey Arrhenius laws, where the diffusion perpendicular to the tetragonal axis is faster by two to three orders of magnitude than parallel to it. The activation enthalpies for diffusion perpendicular and parallel to the tetragonal axis are Q perpendicular to = 468 kJ mol -1 (4.85 eV) and Q parallel = 586 kJ mol -1 (6.07 eV), respectively. Diffusion of Si and its homologous element Ge is fast and is mediated by thermal vacancies of the Si sublattice of MoSi 2 . The diffusion of Mo is by several orders of magnitude slower than the diffusion of Si and Ge. This large difference suggests that Si and Mo diffusion are decoupled and that the diffusion of Mo likely takes place via vacancies on the Mo sublattice. (orig.)

  10. Secondary pancreatic involvement by a diffuse large B-cell lymphoma presenting as acute pancreatitis

    Institute of Scientific and Technical Information of China (English)

    M Wasif Saif; Sapna Khubchandani; Marek Walczak

    2007-01-01

    Diffuse large B-cell lymphoma is the most common type of non-Hodgkin's lymphoma. More than 50% of patients have some site of extra-nodal involvement at diagnosis,including the gastrointestinal tract and bone marrow.However, a diffuse large B-cell lymphoma presenting as acute pancreatitis is rare. A 57-year-old female presented with abdominal pain and matted lymph nodes in her axilla. She was admitted with a diagnosis of acute pancreatitis. Abdominal computed tomography (CT) scan showed diffusely enlarged pancreas due to infiltrative neoplasm and peripancreatic lymphadenopathy. Biopsy of the axillary mass revealed a large B-cell lymphoma.The patient was classified as stage Ⅳ, based on the Ann Arbor Classification, and as having a high-risk lymphoma,based on the International Prognostic Index. She was started on chemotherapy with CHOP (cyclophosphamide,doxorubicin, vincristine and prednisone). Within a week after chemotherapy, the patient's abdominal pain resolved. Follow-up CT scan of the abdomen revealed a marked decrease in the size of the pancreas and peripancreatic lymphadenopathy. A literature search revealed only seven cases of primary involvement of the pancreas in B-cell lymphoma presenting as acute pancreatitis. However, only one case of secondary pancreatic involvement by B-cell lymphoma presenting as acute pancreatitis has been published. Our case appears to be the second report of such a manifestation.Both cases responded well to chemotherapy.

  11. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  12. Batch Computed Tomography Analysis of Projectiles

    Science.gov (United States)

    2016-05-01

    ARL-TR-7681 ● MAY 2016 US Army Research Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt, Chris M...Laboratory Batch Computed Tomography Analysis of Projectiles by Michael C Golt and Matthew S Bratcher Weapons and Materials Research...values to account for projectile variability in the ballistic evaluation of armor. 15. SUBJECT TERMS computed tomography , CT, BS41, projectiles

  13. Intramuscular manifestation of non-Hodgkin lymphoma and myeloma: Prevalence, clinical signs, and computed tomography features

    Energy Technology Data Exchange (ETDEWEB)

    Surov, Alexey; Spielmann, Rolf-Peter; Behrmann, Curd (Dept. of Radiology, Martin Luther Univ., Halle-Wittenberg (Germany)), e-mail: alex.surow@medizin.uni-halle.de; Holzhausen, Hans-Juergen (Dept. of Hematology/Oncology, Martin Luther Univ., Halle-Wittenberg (Germany)); Arnold, Dirk (Dept. of Pathology, Martin Luther Univ., Halle-Wittenberg (Germany)); Schmidt, Joerg (Dept. of Medical Statistics and Controlling, Martin Luther Univ., Halle-Wittenberg (Germany))

    2010-01-15

    Background: Intramuscular manifestations of malignant immuno proliferative diseases (IMMID) are very rare. Purpose: To determine the prevalence and the clinical features of IMMID in a large series of patients, and to analyze their radiological appearances. Material and Methods: Between 1997 and 2007, 20 patients with IMMID (non-Hodgkin lymphoma [NHL], n=14, and myeloma, n=6) were identified. All patients underwent computed tomography (CT). In five cases, magnetic resonance imaging (MRI) was additionally performed. Results: Clinically, 16 patients presented with local pain and soft-tissue swelling. In four patients, IMMID was found incidentally. The most common site was the erector spinae muscle, followed by the iliopsoas and pelvic muscles. In 13 cases of IMMID, diffuse mass-forming muscle infiltration was found. Focal intramuscular masses were identified in seven cases. Conclusion: NHL mostly manifests as diffuse muscle enlargement, whereas myelomas form focal intramuscular masses. Nevertheless, CT and MR appearances are nonspecific and can be misinterpreted as muscle sarcoma or inflammatory disease. Although rare, muscle involvement should be considered in the differential diagnosis of muscle disorders in patients with non-Hodgkin lymphoma and myeloma

  14. Computed tomography in the CSF seeding of brain tumors

    International Nuclear Information System (INIS)

    Nakagawa, Yoshio; Fujimoto, Masahito; Naruse, Shoji; Ueda, Satoshi; Hirakawa, Kimiyoshi

    1981-01-01

    In the past three years nine cases of brain tumors with CSF seeding have been revealed by computed tomography (CT). We have been analyzing the CT pattern of CSF seeding, CSF cytology, and spinal metastasis. The brain tumors were classified as follows: five medulloblastomas, two glioblastomas, one germinoma, and one meningeal carcinomatosis. Their CT patterns were divided into three groups: 1) diffuse seeding of the basal cisterns. 2) invasion of the ventricular wall. 3) solitary metastasis in the ventricle. The subarachnoid seeding included four medulloblastomas and one meningeal carcinomatosis. The second type of seeding included two glioblastomas and one germinoma. One medulloblastoma had a single metastasis in the lateral ventricle. In the medulloblastomas, the diffuse seeding of the basal cisterns was more common than the invasion of the ventricular wall or solitary metastasis in the ventricle. Medulloblastomas were also accompanied by spinal metastasis. Because there were many cases of spinal metastasis in the first type of seeding, we concluded that there was a definite correlation between the CSF seeding of the basal cisterns and spinal metastasis. Needless to say, CT was the most important method for the diagnosis of the CSF seeding of brain tumors. However, because there was a case of CSF seeding which had not been demonstrated by CT, we also emphasized the importance of neurological examination and CSF cytology in the diagnosis of the CSF seeding of brain tumors. (author)

  15. Computed tomography of pulmonary nodules

    International Nuclear Information System (INIS)

    Nakata, Hajime; Honda, Hiroshi; Nakayama, Chikashi; Kimoto, Tatsuya; Nakayama, Takashi

    1983-01-01

    We have evaluated the value of computed tomography (CT) in distinguishing benign and malignant pulmonary nodules. CT was performed on 30 cases of solitary pulmonary nodules consisting of 17 primary lung cancers, 3 metastatic tumors and 10 benign nodules. The CT number was calculated for each lesion. Three benign nodules showed CT numbers well above the range of malignant nodules, and only in one of them was calcification visible on conventional tomography. In 6 benign nodules, the CT numbers overlapped those of malignant lesion and could not be differentiated. Thus the measurement of CT number can be useful to confirm the benign nature of certain nodules when calcification is unclear or not visible on conventional tomography. As for the morphological observation of the nodule, CT was not superior to conventional tomography and its value seems to be limited. (author)

  16. Demonstration of non-Gaussian restricted diffusion in tumor cells using diffusion-time dependent diffusion weighted MR contrast

    Directory of Open Access Journals (Sweden)

    Tuva Roaldsdatter Hope

    2016-08-01

    Full Text Available The diffusion weighted imaging (DWI technique enables quantification of water mobility for probing microstructural properties of biological tissue, and has become an effective tool for collecting information about the underlying pathology of cancerous tissue. Measurements using multiple b-values have indicated a bi-exponential signal attenuation, ascribed to fast (high ADC and slow (low ADC diffusion components. In this empirical study, we investigate the properties of the diffusion time (∆ - dependent components of the diffusion-weighted (DW signal in a constant b-value experiment. A Xenograft GBM mouse was imaged using ∆ = 11 ms, 20 ms, 40 ms, 60 ms and b=500-4000 s/mm2 in intervals of 500s/mm2. Data was corrected for EPI distortions and the ∆-dependence on the DW signal was measured within three regions of interest (intermediate- and high-density tumor regions and normal appearing brain tissue regions (NAB. In this empirical study we verify the assumption that the slow decaying component of the DW-signal is non-Gaussian and dependent on ∆, consistent with restricted diffusion of the intracellular space. As the DW-signal as a function of ∆ is specific to restricted diffusion, manipulating ∆ at constant b-value (cb provides a complementary and direct approach for separating the restricted from the hindered diffusion component. Our results show that only tumor tissue signal of our data demonstrate ∆-dependence, based on a bi-exponential model with a restricted diffusion component, we successfully estimated the restricted ADC, signal volume fraction and cell size within each tumor ROI.

  17. Hereditary Diffuse Gastric Cancer

    Science.gov (United States)

    ... Hereditary Diffuse Gastric Cancer Request Permissions Hereditary Diffuse Gastric Cancer Approved by the Cancer.Net Editorial Board , 10/2017 What is hereditary diffuse gastric cancer? Hereditary diffuse gastric cancer (HDGC) is a rare ...

  18. Hybrid Single Photon Emission Computed Tomography/Computed Tomography Sulphur Colloid Scintigraphy in Focal Nodular Hyperplasia

    International Nuclear Information System (INIS)

    Bhoil, Amit; Gayana, Shankramurthy; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2013-01-01

    It is important to differentiate focal nodular hyperplasia (FNH), a benign condition of liver most commonly affecting women, from other neoplasm such as hepatic adenoma and metastasis. The functional reticuloendothelial features of FNH can be demonstrated by scintigraphy. We present a case of breast cancer in whom fluorodeoxyglucose positron emission tomography/computerized tomography (CT) showed a homogenous hyperdense lesion in liver, which on Tc99m sulfur colloid single-photon emission computed tomography/CT was found to have increased focal tracer uptake suggestive of FNH

  19. Does non-echo-planar diffusion-weighted magnetic resonance imaging have a role in assisting the clinical diagnosis of cholesteatoma in selected cases?

    Science.gov (United States)

    Nash, R; Lingam, R K; Chandrasekharan, D; Singh, A

    2018-03-01

    To determine the diagnostic performance of diffusion-weighted magnetic resonance imaging in the assessment of patients with suspected, but not clinically evident, cholesteatoma. A retrospective analysis of a prospectively collected database of non-echo-planar diffusion-weighted magnetic resonance imaging studies (using a half-Fourier single-shot turbo-spin echo sequence) was conducted. Clinical records were retrospectively reviewed to determine indications for imaging and operative findings. Seventy-eight investigations in 74 patients with suspected cholesteatoma aged 5.7-79.2 years (mean, 41.7 years) were identified. Operative confirmation was available in 44 ears. Diagnostic accuracy of the imaging technique was calculated using operative findings as a 'gold standard'. Sensitivity of the investigation was examined via comparison with clinically evident cholesteatoma. The accuracy of diffusion-weighted magnetic resonance imaging in assessment of suspected cholesteatoma was 63.6 per cent. The imaging technique was significantly less accurate in assessment of suspected cholesteatoma than clinically evident disease (p < 0.001). Computed tomography and diffusion-weighted magnetic resonance imaging may be complementary in assessment of suspected cholesteatoma, but should be used with caution, and clinical judgement is paramount.

  20. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  1. Matlab enhanced multi-threaded tomography optimization sequence (MEMTOS)

    International Nuclear Information System (INIS)

    Lum, Edward S.; Pope, Chad L.

    2016-01-01

    Highlights: • Monte Carlo simulation of spent nuclear fuel assembly neutron computed tomography. • Optimized parallel calculations conducted from within the MATLAB environment. • Projection difference technique used to identify anomalies in spent nuclear fuel assemblies. - Abstract: One challenge associated with spent nuclear fuel assemblies is the lack of non-destructive analysis techniques to determine if fuel pins have been removed or replaced or if there are significant defects associated with fuel pins deep within a fuel assembly. Neutron computed tomography is a promising technique for addressing these qualitative issues. Monte Carlo simulation of spent nuclear fuel neutron computed tomography allows inexpensive process investigation and optimization. The main purpose of this work is to provide a fully automated advanced simulation framework for the analysis of spent nuclear fuel inspection using neutron computed tomography. The simulation framework, called Matlab Enhanced Multi-Threaded Tomography Optimization Sequence (MEMTOS) not only automates the simulation process, but also generates superior tomography image results. MEMTOS is written in the MATLAB scripting language and addresses file management, parallel Monte Carlo execution, results extraction, and tomography image generation. This paper describes the mathematical basis for neutron computed tomography, the Monte Carlo technique used to simulate neutron computed tomography, and the overall tomography simulation optimization algorithm. Sequence results presented include overall simulation speed enhancement, tomography and image results obtained for Experimental Breeder Reactor II spent fuel assemblies and light water reactor fuel assemblies. Optimization using a projection difference technique are also described.

  2. Simple simulation of diffusion bridges with application to likelihood inference for diffusions

    DEFF Research Database (Denmark)

    Bladt, Mogens; Sørensen, Michael

    2014-01-01

    the accuracy and efficiency of the approximate method and compare it to exact simulation methods. In the study, our method provides a very good approximation to the distribution of a diffusion bridge for bridges that are likely to occur in applications to statistical inference. To illustrate the usefulness......With a view to statistical inference for discretely observed diffusion models, we propose simple methods of simulating diffusion bridges, approximately and exactly. Diffusion bridge simulation plays a fundamental role in likelihood and Bayesian inference for diffusion processes. First a simple......-dimensional diffusions and is applicable to all one-dimensional diffusion processes with finite speed-measure. One advantage of the new approach is that simple simulation methods like the Milstein scheme can be applied to bridge simulation. Another advantage over previous bridge simulation methods is that the proposed...

  3. Study of the uranium-zirconium diffusion; Etude de la diffusion uranium-zirconium

    Energy Technology Data Exchange (ETDEWEB)

    Adda, Y; Mairy, C; Bouchet, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    The intermetallic diffusion of uranium fuel and zirconium used as cladding is studied. Intermetallic diffusion can occur during the cladding of uranium rods and uranium can penetrate the zirconium cladding. Different parameters are involved in this mechanism as structure and mechanical properties of the diffusion area as well as presence of impurities in the metal. The uses of different analysis techniques (micrography, Castaing electronic microprobe, microhardness and autoradiography) have permitted to determine with great accuracy the diffusion coefficient in gamma phase (body centered cubic system) and the results have given important information on the intermetallic diffusion mechanisms. The existence of the Kirkendall effect in the U-Zr diffusion is also an argument in favor of the generality of the diffusion mechanism by vacancies in body centered cubic system. (M.P.)

  4. Monitoring Local Changes in Granite Rock Under Biaxial Test: A Spatiotemporal Imaging Application With Diffuse Waves

    Science.gov (United States)

    Xie, Fan; Ren, Yaqiong; Zhou, Yongsheng; Larose, Eric; Baillet, Laurent

    2018-03-01

    Diffuse acoustic or seismic waves are highly sensitive to detect changes of mechanical properties in heterogeneous geological materials. In particular, thanks to acoustoelasticity, we can quantify stress changes by tracking acoustic or seismic relative velocity changes in the material at test. In this paper, we report on a small-scale laboratory application of an innovative time-lapse tomography technique named Locadiff to image spatiotemporal mechanical changes on a granite sample under biaxial loading, using diffuse waves at ultrasonic frequencies (300 kHz to 900 kHz). We demonstrate the ability of the method to image reversible stress evolution and deformation process, together with the development of reversible and irreversible localized microdamage in the specimen at an early stage. Using full-field infrared thermography, we visualize stress-induced temperature changes and validate stress images obtained from diffuse ultrasound. We demonstrate that the inversion with a good resolution can be achieved with only a limited number of receivers distributed around a single source, all located at the free surface of the specimen. This small-scale experiment is a proof of concept for frictional earthquake-like failure (e.g., stick-slip) research at laboratory scale as well as large-scale seismic applications, potentially including active fault monitoring.

  5. Diagnostic accuracy of coronary angiography with multislice computed tomography applied to 'the Real World'

    International Nuclear Information System (INIS)

    Rodriguez Granillo, Gaston A.; Rosales, Miguel A.; Llaurado, Claudio; Fernandez Pereira, Carlos; Garcia Carcia, Hector M.

    2006-01-01

    Objective: To assess the diagnostic accuracy of Coronary Angiography with Multislice Computed Tomography (MSCT) for the detection of significant coronary artery stenoses. Material and methods: Patients studied had an indication for diagnostic coronary angiography and no history of contrast allergies, renal failure or arrhythmias. A multislice tomography equipment (Brilliance 40, Philips, The Netherlands) with ECG gating was used for image acquisition. A total of 90-125 mI of iodinated contrast was administered by IV route. Obesity, diabetes, diffusely calcified segments with a diameter < 2.0 mm, and segments treated with stents were not considered exclusion criteria. Lesions were defined as significant when the decrease in Iumen was ≥ 50% by MSCT and quantitative coronary angiography (QCA). Results: A total of 38 patients were scanned before the intervention. Of them, one (3%) was excluded because of inadequate image quality. The remaining 37 patients (444 segments), with an adequate quality image, were included in the study (81% men, mean age 62.43 ± 12.5 years, 13.5% diabetics). Mean scan time was 15.12 ± 2.6 seconds, and 444 segments were assessed with both techniques. The number of lesions deemed significant by QCA and MSCT were 88 (17%) and 93 (18%), respectively. Sensitivity, specificity, positive and negative predictive values of MSCT to detect significant stenoses were 82%, 93%, 72% and 96%, respectively. Conclusion: In non-selected patients, coronary angiography by multislice computed tomography exhibits a high negative predictive value for the detection of obstructive coronary disease. (author)

  6. Portal venous gas detected on computed tomography in emergency situations: surgery is still necessary.

    Science.gov (United States)

    Monneuse, Olivier; Pilleul, Frank; Barth, Xavier; Gruner, Laurent; Allaouchiche, Bernard; Valette, Pierre-Jean; Tissot, E

    2007-05-01

    Portal venous gas (PVG) has been reported to be associated with lethal surgical diagnosis. Recent studies tend to confirm the clinical significance of gas in the portal vein; however, some patients are managed without surgical treatment. The aim of this study was to assess both the diagnoses and the treatment of patients with PVG in an emergency surgical setting. We performed a retrospective chart review of 15 patients with PVG in the emergency setting detected by computed tomography (CT) between July 1999 and July 2004. Characteristics assessed included age, sex, clinical presentation, first CT diagnosis of both PVG and the underlying pathology, American Society of Anesthesiologists (ASA) score, surgical findings, final clinical diagnosis, duration of hospitalization, and evolution of the illness/mortality. All patients were examined one month after operation. This series of 5 women and 10 men ranged in age from 38 to 90 years at the time they underwent emergency surgical treatment. The mean preoperative ASA score was 4.20. Computed tomography diagnosed the underlying pathology in all cases: bowel obstruction (4 cases), bowel necrosis (9 cases), and diffuse peritonitis (2 cases). The mean length of hospital stay was 12.4 days. The mortality rate was 46.6%; (7 patients). A wide range of pathologies can generate PVG. Computed tomography can detect both the presence of gas and the underlying pathology. In emergency situations, all the diagnosed causal pathologies required a surgical procedure without delay. We report that the prognosis was related to the pathology itself and was not influenced by the presence of PVG.

  7. Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Mogensen, Mette; Themstrup, Lotte; Banzhaf, Christina

    2014-01-01

    Optical coherence tomography (OCT) has developed rapidly since its first realisation in medicine and is currently an emerging technology in the diagnosis of skin disease. OCT is an interferometric technique that detects reflected and backscattered light from tissue and is often described as the o......Optical coherence tomography (OCT) has developed rapidly since its first realisation in medicine and is currently an emerging technology in the diagnosis of skin disease. OCT is an interferometric technique that detects reflected and backscattered light from tissue and is often described...

  8. Solid state diffusion in zirconium-copper and zirconium-nickel systems. Study of the intermetallic compounds formed; Diffusion a l'etat solide dans les systemes zirconium-cuivre et zirconium-nickel. Etude des composes intermetalliques formes

    Energy Technology Data Exchange (ETDEWEB)

    Meny, L; Champigny, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    Solid state diffusion has been provoked in pure Zr-Cu and Zr-Ni metal couples. The tests were carried out in the following experimental conditions : the samples were maintained at a mechanical pressure of 30 kg/cm{sup 2}; annealing was carried out in a secondary vacuum during 100 and 500 hours, at temperatures of between 650 C and 900 C. In all cases, a diffusion zone made up of several parallel layers was formed. The various intermetallic compounds have been studied by metallography (optical microscopy and micro-hardness) X-ray diffraction and micro-analysis with an electronic probe. In the Zr-Cu system, six compounds have been determined, Zr{sub 2}Cu, ZrCu, Zr{sub 2}Cu{sub 3}, ZrCu{sub 4} and ZrCu{sub 5}. These results confirm a recent publication mentioning for the first time the existence of ZrCu{sub 5} and demonstrating the formulae ZrCu{sub 3} and ZrCu{sub 4}. In a similar manner, we have found six compounds, stable at room temperature, in the Zr-Ni system: these are Zr{sub 2}Ni, ZrNi, Zr{sub 7}Ni{sub 10}, ZrNi{sub 3}, ZrNi{sub 4} and ZrNi{sub 5}; the results of American workers are confirmed for four of these compounds; however we identify as ZrNi{sub 3} and ZrNi{sub 4} the compounds for which they proposed the formulae Zr{sub 2}Ni{sub 5} and Zr{sub 2}Ni{sub 7}. A comparison of these results suggests that the two systems ZrCu and ZrNi have the same type of equilibrium diagrams. (authors) [French] Des diffusions a l'etat solide ont ete effectuees entre les couples de metaux purs Zr-Cu et Zr-Ni. Les essais ont eu lieu dans les conditions experimentales suivantes: les echantillons ont ete maintenus par une pression mecanique de 3O kg/cm{sup 2}; les recuits ont ete effectues sous vide secondaire pendant des temps de 100 et 500 heures, a des temperatures comprises entre 650 C et 900 C. Dans tous les cas, il y a eu formation d'une zone de diffusion formee de plusieurs couches paralleles. Les differents composes intermetalliques ont ete etudies par metallographie

  9. Diffuse ceiling ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen

    Diffuse ceiling ventilation is an innovative ventilation concept where the suspended ceiling serves as air diffuser to supply fresh air into the room. Compared with conventional ventilation systems, diffuse ceiling ventilation can significantly reduce or even eliminate draught risk due to the low...

  10. Sequential computerized tomography changes and related final outcome in severe head injury patients

    International Nuclear Information System (INIS)

    Lobato, R.D.; Gomez, P.A.; Alday, R.

    1997-01-01

    The authors analyzed the serial computerized tomography (CT) findings in a large series of severely head injured patients in order to assess the variability in gross intracranial pathology through the acute posttraumatic period and determine the most common patterns of CT change. A second aim was to compare the prognostic significance of the different CT diagnostic categories used in the study (Traumatic Coma Data Bank CT pathological classification) when gleaned either from the initial (postadmission) or the control CT scans, and determine the extent to which having a second CT scan provides more prognostic information than only one scan. 92 patients (13.3 % of the total population) died soon after injury. Of the 587 who survived long enough to have at least one control CT scan 23.6 % developed new diffuse brain swelling, and 20.9 % new focal mass lesions most of which had to be evacuated. The relative risk for requiring a delayed operation as related to the diagnostic category established by using the initial CT scans was by decreasing order: diffuse injury IV (30.7 %), diffuse injury III (30.5 %), non evacuated mass (20 %), evacuated mass (20.2 %), diffuse injury II (12.1 %), and diffuse injury I (8.6 %). Overall, 51.2 % of the patients developed significant CT changes (for worse or better) occurring either spontaneously or following surgery, and their final outcomes were more closely related to the control than to the initial CT diagnoses. In fact, the final outcome was more accurately predicted by using the control CT scans (81.2 % of the cases) than by using the initial CT scans (71.5 % of the cases only). Since the majority of relevant CT changes developed within 48 hours after injury a pathological categorization made by using an early control CT scan seems to be most useful for prognostic purposes. Prognosis associated with the CT pathological categories used in the study was similar independently of the moment of the acute posttraumatic period at which

  11. Impact d'une modulation duale sur les performances d'une liaison ...

    African Journals Online (AJOL)

    Le présent document présente la technique de modulation duale Fréquence - Amplitude dans le cas d'une liaison optique du type IM-DD. Ce travail révèle que la modulation duale Fréquence - Amplitude permet de générer un signal à bande latérale unique. Les performances d'une liaison optique IM-DD basée sur cette ...

  12. 2530-IJBCS-Article-Alain S A Ambe

    African Journals Online (AJOL)

    hp

    vitro sur des cellules HFF a mis en évidence des effets cytotoxiques de la plante sur les cellules humaines à des ... compte le coût élevé des médicaments ..... solubilisés dans du diméthylsulfoxyde. (DMSO) 10 mM puis l'absorbance ou la densité optique (DO) a été mesuré. La mesure de la densité optique (DO) de chaque ...

  13. Atom Probe Tomography of Phase and Grain Boundaries in Experimentally-Deformed and Hot-Pressed Wehrlite

    Science.gov (United States)

    Cukjati, J.; Parman, S. W.; Cooper, R. F.; Zhao, N.

    2017-12-01

    Atom probe tomography (APT) was used to characterize the chemistry of three grain boundaries: an olivine-olivine (ol-ol) and olivine-clinopyroxene (ol-cpx) boundary in fine-grained experimentally-deformed wehrlite and an ol-cpx boundary in a fine-grained, hot-pressed wehrlite. Grain boundaries were extracted and formed into APT tips using a focused ion beam (FIB). The tips were analyzed in a reflectron-equipped LEAP4000HR (Harvard University) at 1% or 0.5% detection rate, 5pJ laser energy and 100kHz pulse rate. Total ion counts are between 40 and 100 million per tip. Examination of grain and phase boundaries in wehrlite are of interest since slow-diffusing and olivine-incompatible cations present in cpx (e.g. Ca and Al) may control diffusion-accommodated grain boundary sliding and affect mantle rheology (Sundberg & Cooper, 2008). At steady state, ol-cpx aggregates are weaker than either ol or cpx end member, the results of which are not currently well-explained. We investigate grain boundary widths to understand the transport of olivine-incompatible elements. Widths of grain/phase boundary chemical segregation are between 3nm and 6nm for deformed ol-ol and ol-cpx samples; minimally-deformed (hot-pressed) samples having slightly wider chemical segregation widths. Chemical segregation widths were determined from profiles of Na, Al, P, Cl, K, Ca, or Ni, although not all listed elements can be used for all samples (e.g. Na, K segregation profiles can only be observed for ol-ol sample). These estimates are consistent with prior estimates of grain boundary segregation by atom probe tomography on ol-ol and opx-opx samples (Bachhav et al., 2015) and are less than ol-ol interface widths analyzed by STEM/EDX (Hiraga, Anderson, & Kohlstedt, 2007). STEM/EDX will be performed on deformed wehrlite to investigate chemical profile as a function of applied stress orientation and at length scales between those observable by APT and EPMA. Determination of phase boundary chemistry and

  14. Diffusion of gases in solids: rare gas diffusion in solids; tritium diffusion in fission and fusion reactor metals. Final report

    International Nuclear Information System (INIS)

    Abraham, P.M.; Chandra, D.; Mintz, J.M.; Elleman, T.S.; Verghese, K.

    1976-01-01

    Major results of tritium and rare gas diffusion research conducted under the contract are summarized. The materials studied were austenitic stainless steels, Zircaloy, and niobium. In all three of the metal systems investigated, tritium release rates were found to be inhibited by surface oxide films. The effective diffusion coefficients that control tritium release from surface films on Zircaloy and niobium were determined to be eight to ten orders of magnitude lower than the bulk diffusion coefficients. A rapid component of diffusion due to grain boundaries was identified in stainless steels. The grain boundary diffusion coefficient was determined to be about six orders of magnitude greater than the bulk diffusion coefficient for tritium in stainless steel. In Zircaloy clad fuel pins, the permeation rate of tritium through the cladding is rate-limited by the extremely slow diffusion rate in the surface films. Tritium diffusion rates through surface oxide films on niobium appear to be controlled by cracks in the surface films at temperatures up to 600 0 C. Beyond 600 0 C, the cracks appear to heal, thereby increasing the activation energy for diffusion through the oxide film. The steady-state diffusion of tritium in a fusion reactor blanket has been evaluated in order to calculate the equilibrium tritium transport rate, approximate time to equilibrium, and tritium inventory in various regions of the reactor blanket as a function of selected blanket parameters. Values for these quantities have been tabulated

  15. Diffusion Modeling: A Study of the Diffusion of “Jatropha Curcas ...

    African Journals Online (AJOL)

    Consequently, the study recommended the use of diffusion networks which integrate interpersonal networks, and multimedia strategies for the effective diffusion of innovation such as Jacodiesel in Adamawa State and other parts of the country. Keywords: Sustainability, Diffusion, Innovation, Communicative Influence, ...

  16. Anomalous diffusion in niobium. Study of solute diffusion mechanism of iron in niobium

    International Nuclear Information System (INIS)

    Ablitzer, D.

    1977-01-01

    In order to explain anomalously high diffusion velocities observed for iron diffusion in niobium, the following parameters were measured: isotope effect, b factor (which expresses the effect of iron on niobium self-diffusion), self-diffusion coefficient of niobium, solute diffusion coefficient of iron in niobium. The results obtained show that neither pure vacancy models, nor diffusion in the lattice defects (dislocations, sub-boundaries, grain boundaries), nor pure interstitialy mechanisms, nor simple or cyclic exchange mechanisms agree with experiments. A mechanism is proposed which considers an equilibrium between substitution iron atoms and interstitial iron atoms. The diffusion of iron then occurs through interstitial vancancy pairs [fr

  17. X-ray Compton line scan tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kupsch, Andreas; Lange, Axel; Jaenisch, Gerd-Ruediger [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany). Fachgruppe 8.5 - Mikro-ZfP; Hentschel, Manfred P. [Technische Univ. Berlin (Germany); Kardjilov, Nikolay; Markoetter, Henning; Hilger, Andre; Manke, Ingo [Helmholtz-Zentrum Berlin (HZB) (Germany); Toetzke, Christian [Potsdam Univ. (Germany)

    2015-07-01

    The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.

  18. 18 F-fluorodeoxyglucose positron emission tomography-computed tomography for preoperative lymph node staging in patients undergoing radical cystectomy for bladder cancer: a prospective study.

    Science.gov (United States)

    Hitier-Berthault, Maryam; Ansquer, Catherine; Branchereau, Julien; Renaudin, Karine; Bodere, Françoise; Bouchot, Olivier; Rigaud, Jérôme

    2013-08-01

    The objective of our study was to analyze the diagnostic performance of (18) F-fluorodeoxyglucose positron emission tomography-computed tomography for lymph node staging in patients with bladder cancer before radical cystectomy and to compare it with that of computed tomography. A total of 52 patients operated on between 2005 and 2010 were prospectively included in this prospective, mono-institutional, open, non-randomized pilot study. Patients who had received neoadjuvant chemotherapy or radiotherapy were excluded. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography in addition to computed tomography was carried out for lymph node staging of bladder cancer before radical cystectomy. Lymph node dissection during radical cystectomy was carried out. Findings from (18) F-fluorodeoxyglucose positron emission tomography-computed tomography and computed tomography were compared with the results of definitive histological examination of the lymph node dissection. The diagnostic performance of the two imaging modalities was assessed and compared. The mean number of lymph nodes removed during lymph node dissection was 16.5 ± 10.9. Lymph node metastasis was confirmed on histological examination in 22 cases (42.3%). This had been suspected in five cases (9.6%) on computed tomography and in 12 cases (23.1%) on (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. Sensitivity, specificity, positive predictive value, negative predictive value, relative risk and accuracy were 9.1%, 90%, 40%, 57.4%, 0.91 and 55.7%, respectively, for computed tomography, and 36.4%, 86.7%, 66.7%, 65%, 2.72, 65.4%, respectively, for (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography is more reliable than computed tomography for preoperative lymph node staging in patients with invasive bladder carcinoma undergoing radical cystectomy. © 2012 The Japanese

  19. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  20. The value of computed tomography in ''sciatica''

    International Nuclear Information System (INIS)

    Boehm-Jurkovic, H.; Hammer, B.

    1981-01-01

    13 cases of therapy-resistant lumboischialgia without herniated disk, caused in 12 cases by a tumour and in 1 case by an abscess, were examined by computed tomography of the lumbar and pelvic region. This method is indicated immediately after insufficient results of conventional X-ray methods (including tomography) and of lumbosacral radiculography. The computed tomography is indispensable also in patients with ''sciatica'' with a known malignoma. The information given by computed tomography is essential for the therapy planning. (author)

  1. A Case of Diffuse Large B-Cell Lymphoma Mimicking Primary Effusion Lymphoma-Like Lymphoma

    Directory of Open Access Journals (Sweden)

    Daisuke Usuda

    2017-11-01

    Full Text Available A 93-year-old female was transferred to the emergency ward of our hospital due to disturbance of consciousness and hypotension. Computed tomography showed bilateral pleural and pericardial effusion without evidence of tumor masses or lymphadenopathy. Cytodiagnosis of pleural effusion revealed proliferation of atypical lymphoid-like cells with pan-B surface markers. We suspected primary effusion lymphoma-like lymphoma; however, the monoclonality of these cells was not confirmed. Cytodiagnosis of bone marrow revealed lymphoma cells with monoclonal B-cell markers. These findings prompted a diagnosis of diffuse large B-cell lymphoma with bone marrow invasion. In the case of pericardial or pleural effusion, clinicians should consider carefully both hematological malignancy and its classification.

  2. Inpainting using airy diffusion

    Science.gov (United States)

    Lorduy Hernandez, Sara

    2015-09-01

    One inpainting procedure based on Airy diffusion is proposed, implemented via Maple and applied to some digital images. Airy diffusion is a partial differential equation with spatial derivatives of third order in contrast with the usual diffusion with spatial derivatives of second order. Airy diffusion generates the Airy semigroup in terms of the Airy functions which can be rewritten in terms of Bessel functions. The Airy diffusion can be used to smooth an image with the corresponding noise elimination via convolution. Also the Airy diffusion can be used to erase objects from an image. We build an algorithm using the Maple package ImageTools and such algorithm is tested using some images. Our results using Airy diffusion are compared with the similar results using standard diffusion. We observe that Airy diffusion generates powerful filters for image processing which could be incorporated in the usual packages for image processing such as ImageJ and Photoshop. Also is interesting to consider the possibility to incorporate the Airy filters as applications for smartphones and smart-glasses.

  3. Diffusion in compacted betonite

    International Nuclear Information System (INIS)

    Muurinen, A.; Rantanen, J.

    1985-01-01

    The objective of this report is to collect the literature bearing on the diffusion in compacted betonite, which has been suggested as possible buffer material for the disposal of spent fuel. Diffusion in a porous, water-saturated material is usually described as diffusion in the pore-water where sorption on the solid matter can delay the migration in the instationary state. There are also models which take into consideration that the sorbed molecules can also move while being sorbed. Diffusion experiments in compacted bentonite have been reported by many authors. Gases, anions, cations and actinides have been used as diffusing molecules. The report collects the results and the information on the measurement methods. On the basis of the results can be concluded that different particles possibly follow different diffusion mechanisms. The parameters which affect the diffusion seem to be for example the size, the electric charge and the sorption properties of the diffusing molecule. The report also suggest the parameters to be used in the diffusion calculation of the safety analyses of spent fuel disposal. (author)

  4. Elucidating structural order and disorder phenomena in mullite-type Al4B2O9 by automated electron diffraction tomography

    International Nuclear Information System (INIS)

    Zhao, Haishuang; Krysiak, Yaşar; Hoffmann, Kristin; Barton, Bastian; Molina-Luna, Leopoldo; Neder, Reinhard B.; Kleebe, Hans-Joachim; Gesing, Thorsten M.; Schneider, Hartmut; Fischer, Reinhard X.

    2017-01-01

    The crystal structure and disorder phenomena of Al 4 B 2 O 9 , an aluminum borate from the mullite-type family, were studied using automated diffraction tomography (ADT), a recently established method for collection and analysis of electron diffraction data. Al 4 B 2 O 9 , prepared by sol-gel approach, crystallizes in the monoclinic space group C2/m. The ab initio structure determination based on three-dimensional electron diffraction data from single ordered crystals reveals that edge-connected AlO 6 octahedra expanding along the b axis constitute the backbone. The ordered structure (A) was confirmed by TEM and HAADF-STEM images. Furthermore, disordered crystals with diffuse scattering along the b axis are observed. Analysis of the modulation pattern implies a mean superstructure (AAB) with a threefold b axis, where B corresponds to an A layer shifted by ½a and ½c. Diffraction patterns simulated for the AAB sequence including additional stacking disorder are in good agreement with experimental electron diffraction patterns. - Graphical abstract: Crystal structure and disorder phenomena of B-rich Al 4 B 2 O 9 studied by automated electron diffraction tomography (ADT) and described by diffraction simulation using DISCUS. - Highlights: • Ab-initio structure solution by electron diffraction from single nanocrystals. • Detected modulation corresponding mainly to three-fold superstructure. • Diffuse diffraction streaks caused by stacking faults in disordered crystals. • Observed streaks explained by simulated electron diffraction patterns.

  5. Use of Computed Tomography and Positron Emission Tomography/Computed Tomography for Staging of Local Extent in Patients With Malignant Pleural Mesothelioma

    OpenAIRE

    Frauenfelder, Thomas; Kestenholz, Peter; Hunziker, Roger; Nguyen, Thi Dan Linh; Fries, Martina; Veit-Haibach, Patrick; Husmann, Lars; Stahel, Rolf; Weder, Walter; Opitz, Isabelle

    2015-01-01

    PURPOSE The objective of this study was to determine the diagnostic value of computed tomography (CT) and positron emission tomography (PET)/CT for staging of malignant pleural mesothelioma (MPM) in patients undergoing induction chemotherapy. METHODS Sixty-two patients (median age, 61 years; female: n = 9) with proven MPM underwent CT after induction chemotherapy. Of these, 28 underwent additional PET/CT. Extrapleural pneumonectomy was performed for pathological TNM staging. Clinical TNM s...

  6. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  7. Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

    NARCIS (Netherlands)

    Piers, LH; Dorgelo, J; Tio, RA; Jessurun, GAJ; Oudkerk, M; Zijlstra, F

    This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic

  8. The accuracy of the diffusion theory component of removal-diffusion theory

    International Nuclear Information System (INIS)

    Donnelly, I.J.

    1976-03-01

    The neutron fluxes in five neutron shields consisting of water, concrete, graphite, iron and an iron-water lattice respectively, have been calculated using P 1 theory, diffusion theory with the usual transport correction for anisotropic scattering (DT), and diffusion theory with a diagonal transport correction (DDT). The calculations have been repeated using transport theory for the flux above 0.5 MeV and the diffusion theories for lower energies. Comparisons with transport theory calculations reveal the accuracy of each diffusion theory when it is used for flux evaluation at all energies, and also its accuracy when used for flux evaluation below 0.5 MeV given the correct flux above 0.5 MeV. It is concluded that the diffusion component of removal-diffusion theory has adequate accuracy unless the high energy diffusion entering the shield is significantly larger than the removal flux. In general, P 1 and DT are more accurate than DDT and give similar fluxes except for shields having a large hydrogen content, in which case DT is better. Therefore it is recommended that DT be used in preference to P 1 theory or DDT. (author)

  9. 21 CFR 892.1310 - Nuclear tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nuclear tomography system. 892.1310 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1310 Nuclear tomography system. (a) Identification. A nuclear tomography system is a device intended to detect nuclear radiation in the body and...

  10. Cosmic ray diffusion: report of the workshop in cosmic ray diffusion theory

    International Nuclear Information System (INIS)

    Birmingham, T.J.; Jones, F.C.

    1975-02-01

    A workshop in cosmic ray diffusion theory was held at Goddard Space Flight Center on May 16-17, 1974. Topics discussed and summarized are: (1) cosmic ray measurements as related to diffusion theory; (2) quasi-linear theory, nonlinear theory, and computer simulation of cosmic ray pitch-angle diffusion; and (3) magnetic field fluctuation measurements as related to diffusion theory. (auth)

  11. single photon emission tomography and positron emission tomography - Part 1 (October 2012), Part 2 (October 2010)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2010-10-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) and the positron emission tomography (PET) imaging techniques. Part 1 Content: 1 - Introduction: anatomic, functional and molecular imaging; 2 - Radiotracers: chemical and physical constraints, gamma photon emitters, positon emitters, radioisotopes production, emitters type and imaging techniques; 3 - Gamma cameras; 4 - Quantification in emission tomography: attenuation, scattering, un-stationary spatial resolution; 5 - Synthesis and conclusion. Part 2 content: 1 - Positon emitters; 2 - Positons detection: Coincidence detection (electronic collimation, PET detectors with gamma cameras, dedicated PET detectors, spectrometry); PET detectors type; time-of-flight PET; 2D PET; 3D PET; 3 - Quantification in emission tomography: detected events, attenuation, scattering, fortuitous coincidences, standardisation; 4 - Common SPECT and PET problems: partial volume effect, movement, tomographic reconstruction, calibration, dead time; 5 - Synthesis and conclusion

  12. 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Tuberculosis: Spectrum of Manifestations.

    Science.gov (United States)

    Agarwal, Krishan Kant; Behera, Abhishek; Kumar, Rakesh; Bal, Chandrasekhar

    2017-01-01

    The objective of this article is to provide an illustrative tutorial highlighting the utility of 18 F-fluorodeoxyglucose-positron emission tomography/computed tomography ( 18 F-FDG-PET/CT) imaging to detect spectrum of manifestations in patients with tuberculosis (TB). FDG-PET/CT is a powerful tool for early diagnosis, measuring the extent of disease (staging), and consequently for evaluation of response to therapy in patients with TB.

  13. Protean appearance of craniopharyngioma on computed tomography

    International Nuclear Information System (INIS)

    Danziger, A.; Price, H.I.

    1979-01-01

    Craniopharyngiomas present a diverse appearance on computed tomography. Histological diagnosis is not always possible, but computed tomography is of great assistance in the delineation of the tumour as well as of the degree of associated hydrocephalus. Computed tomography also enables rapid non-invasive follow-up after surgery or radiotherapy, or both

  14. Optimal experiment design for quantum state tomography: Fair, precise, and minimal tomography

    International Nuclear Information System (INIS)

    Nunn, J.; Smith, B. J.; Puentes, G.; Walmsley, I. A.; Lundeen, J. S.

    2010-01-01

    Given an experimental setup and a fixed number of measurements, how should one take data to optimally reconstruct the state of a quantum system? The problem of optimal experiment design (OED) for quantum state tomography was first broached by Kosut et al.[R. Kosut, I. Walmsley, and H. Rabitz, e-print arXiv:quant-ph/0411093 (2004)]. Here we provide efficient numerical algorithms for finding the optimal design, and analytic results for the case of 'minimal tomography'. We also introduce the average OED, which is independent of the state to be reconstructed, and the optimal design for tomography (ODT), which minimizes tomographic bias. Monte Carlo simulations confirm the utility of our results for qubits. Finally, we adapt our approach to deal with constrained techniques such as maximum-likelihood estimation. We find that these are less amenable to optimization than cruder reconstruction methods, such as linear inversion.

  15. Amplitude equations for a sub-diffusive reaction-diffusion system

    International Nuclear Information System (INIS)

    Nec, Y; Nepomnyashchy, A A

    2008-01-01

    A sub-diffusive reaction-diffusion system with a positive definite memory operator and a nonlinear reaction term is analysed. Amplitude equations (Ginzburg-Landau type) are derived for short wave (Turing) and long wave (Hopf) bifurcation points

  16. Computed tomography and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography findings in adrenal candidiasis and histoplasmosis: two cases.

    Science.gov (United States)

    Altinmakas, Emre; Guo, Ming; Kundu, Uma R; Habra, Mouhammed Amir; Ng, Chaan

    2015-01-01

    We report the contrast-enhanced computed tomography (CT) and (18)F-fluorodeoxyglucose positron emission tomography findings in adrenal histoplasmosis and candidiasis. Both demonstrated bilateral hypermetabolic heterogeneous adrenal masses with limited wash-out on delayed CT. Adrenal candidiasis has not been previously reported, nor have the CT wash-out findings in either infection. The adrenal imaging findings are indistinguishable from malignancy, which is more common; but in this setting, physicians should be alert to the differential diagnosis of fungal infections, since it can be equally deadly. Published by Elsevier Inc.

  17. Use of an improved simultaneous tomography cassette in linear tomography

    International Nuclear Information System (INIS)

    Egender, G.; Pirker, E.; Gornik, E.; Innsbruck Univ.

    1984-01-01

    An improved simultaneous tomography cassette according to P. Landau was tried out for four months using four tomographs in routine work. The mode of operation is based on accurate control of the relative speeds of the individual x-ray films resulting in simultaneous imaging of 6 equidistant tomographic levels. Clinical testing was effected in 80 cases: nephrotomography, of the lungs, the hilum, and the skeleton. In particular, the article describes imaging of the renal arteries by simultaneous tomography for the purpose of finding out the cause of hypertension, and if there is suspicion of a space-occupying growth in the kidney, basing on the urogram. The specific advantages of this technique are, on the one hand, improved diagnostic efficiency (the tomograms are taken during the same respiratory phase, more rapid diagnosis especially with accident patients), and, on the other hand, an important reduction in the x-ray exposure of the patient; furthermore, the life of the x-ray tube is prolonged, and there is a definite saving of time for both patient and personnel, the image quality being comparable with that of single-layer tomography. (orig.) [de

  18. Comparing staging by positron emission tomography with contrast-enhanced computed tomography and by pathology in head and neck squamous cell carcinoma.

    Science.gov (United States)

    Qualliotine, J R; Mydlarz, W K; Chan, J Y K; Zhou, X; Wang, H; Agrawal, N

    2015-12-01

    This study aimed to evaluate the ability of positron emission tomography with contrast-enhanced computed tomography to correctly stage head and neck squamous cell carcinomas, in comparison with pathological staging. Positron emission tomography computed tomography was used to determine the tumour-node-metastasis classification and overall cancer stage in 85 head and neck squamous cell carcinoma patients who underwent pre-operative imaging using this modality and primary surgery between July 2010 and January 2013. Staging by positron emission tomography computed tomography was retrospectively compared with staging using pathological specimens. Agreement between imaging stage and pathological stage was examined by univariate and multivariate analysis both overall and for each primary tumour site. This imaging modality was 87.5 per cent sensitive and 44.8 per cent specific in identifying regional cervical metastases, and had false positive and false negative rates of 18.8 per cent and 8.2 per cent, respectively. The positive predictive and negative predictive values were 75.4 per cent and 65.0 per cent, respectively. Univariate and multivariate analyses revealed a significant agreement between positron emission tomography computed tomography and pathological node classification in older patients and for the oral cavity primary tumour site. There was significant agreement between both methods in the overall classification only for tumours classified as T3 or greater. Positron emission tomography computed tomography should be used with caution for the pre-operative staging of head and neck cancers because of its high false positive and false negative rates.

  19. Spectral-domain optical coherence tomography findings of the macula in 500 consecutive patients with uveitis.

    Science.gov (United States)

    Grajewski, R S; Boelke, A C; Adler, W; Meyer, S; Caramoy, A; Kirchhof, B; Cursiefen, C; Heindl, L M

    2016-11-01

    PurposeTo analyze the macular structure in a large series of consecutive patients with different types of uveitis using spectral-domain optical coherence tomography (SD-OCT).Patients and methodsFive hundred eyes of 500 consecutive patients with anterior, intermediate, posterior, and panuveitis underwent standardized macular examination using SD-OCT. Central retinal thickness (CRT), macular volume (MV), and presence of cystoid macular edema (CME), diffuse macular edema (DME), serous retinal detachment (SRD), epiretinal membrane with (ERM+) and without (ERM-) retinal surface wrinkling were determined.ResultsThe anatomic location of inflammation affected significantly CRT and MV (Pmacula is recommended for all uveitis patients. CRT, MV, and the incidence of CME were highest in intermediate and panuveitis.

  20. Study of uranium-titanium diffusion; Etude de la diffusion uranium-titane

    Energy Technology Data Exchange (ETDEWEB)

    Adda, Y; Philibert, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Institut de Recherches de la Siderurgie Francaise (IRSID), 78 - Saint-Germain-en-Laye (France)

    1959-07-01

    In the overall scheme of research on the chemical diffusion of uranium and the transition metals we have studied the uranium-titanium system. The diffusion couples are prepared by welding together small plates of uranium and titanium under pressure, using a technique already described by us. After diffusion under vacuum, polished sections of the samples were micro-graphically examined. This inspection showed that intergranular diffusion occurred at temperatures below 650 deg. C. At higher temperatures, the diffusion occurred uniquely throughout the volume of the metal, and the diffusion zone appeared as a succession of micro-graphically distinguishable bands. Study of the rate of increase of these corresponding 'penetration coefficients'. In addition, we have observed important variations in microhardness within the diffusion zone, we have tried to relate these variations to the variation of concentration. This is measured with the Castaing microprobe. We have thus accurately established the concentration-penetration curves for temperatures between 950 and 1075 deg. C. From these curves, we have calculated the diffusion coefficient D as a function of the concentration using Matano's method. At all temperatures, D(c) curve has a U form as for the U-Zr system. The activation energy has a maximum value of 42 kcal/g atom at an atomic concentration of 0,5. Even though we have rarely seen pores in the diffusion zone, we have nevertheless observed an important Kirkendall-effect by studying the displacements x{sub i} of the interface using tungsten wires as markers. These displacements can be expressed as a function of time and temperature by the equation: x{sub i} = 0,9 t {sup 1/2} exp ( - 14600/(RT)). Finally, using Darken's equations we calculated the intrinsic diffusion coefficients Du and Dti as well as the corresponding activation energies. These energies are similar (QU = 38,5 and QTi = 40 kcal/at. g) and also almost the same as those found for the U-Zr system