WorldWideScience

Sample records for tomograph reception system

  1. Transducer project and optimization of the ultra low magnetic field NMR tomograph reception system system

    International Nuclear Information System (INIS)

    Vidoto, Edson Luiz Gea

    1995-01-01

    The aim of the present work was to optimize the signal to noise ratio in our NMR imaging system (TORM 005) by improving transducer's reception quality through better designed coils, balanced tuning circuit for this coils and power decoupling circuits and by reducing interference from the electromagnetic environment. For this purpose, we had to modify the internal electromagnetic shielding and incorporate line filters in the more critical signals paths. Also, new types of coils were developed, improving the signal to noise ratio, and allowing us to make clinical exams with superior quality for several anatomies. Balanced circuits for tuning and matching of the coil were studied and built, allowing a reduction of the coil losses because patient's load. This produced a more reliable coil tuning after positioning each new patient. Circuits to avoid the receiver input overload and decoupling circuits for the isolation of receiver coils from excitation coil were designed and incorporated to the TORM 005. All these alterations of our imaging system (TORM 005) contributed to a significant improvement in the signal to noise ratio, reliability and reproducibility of the system. This permitted to operate the system routinely for clinical applications, research and development in the area of ultra low magnetic field tomography. (author)

  2. A tomograph VMEbus parallel processing data acquisition system

    International Nuclear Information System (INIS)

    Wilkinson, N.A.; Rogers, J.G.; Atkins, M.S.

    1989-01-01

    This paper describes a VME based data acquisition system suitable for the development of Positron Volume Imaging tomographs which use 3-D data for improved image resolution over slice-oriented tomographs. the data acquisition must be flexible enough to accommodate several 3-D reconstruction algorithms; hence, a software-based system is most suitable. Furthermore, because of the increased dimensions and resolution of volume imaging tomographs, the raw data event rate is greater than that of slice-oriented machines. These dual requirements are met by our data acquisition system. Flexibility is achieved through an array of processors connected over a VMEbus, operating asynchronously and in parallel. High raw data throughput is achieved using a dedicated high speed data transfer device available for the VMEbus. The device can attain a raw data rate of 2.5 million coincidence events per second for raw events which are 64 bits wide

  3. The immigrants’ reception system in Italy. Reflections emerging from an experience of reception upon landing

    OpenAIRE

    Concetta Chiara Cannella; Gandolfa Cascio; Francesca Molonia; Serena Vitulo

    2014-01-01

    After the description of the main migration routes toward Italian territory, the article provides an overview of the laws and administrative policy instruments that characterize the system of reception and detention of migrants in Italy. This type of information can help psychosocial workers supporting migrants to better cope with various psychosocial issues, such as the landing in a foreign country. Following a report on the first reception intervention carried out in Palermo, Sicily, by Psi...

  4. A tomograph VMEbus parallel processing data acquisition system

    International Nuclear Information System (INIS)

    Atkins, M.S.; Wilkinson, N.A.; Rogers, J.G.

    1988-11-01

    This paper describes a VME based data acquisition system suitable for the development of Positron Volume Imaging tomographs which use 3-D data for improved image resolution over slice-oriented tomographs. The data acquisition must be flexible enough to accommodate several 3-D reconstruction algorithms; hence, a software-based system is most suitable. Furthermore, because of the increased dimensions and resolution of volume imaging tomographs, the raw data event rate is greater than that of slice-oriented machines. These dual requirements are met by our data acquisition systems. Flexibility is achieved through an array of processors connected over a VMEbus, operating asynchronously and in parallel. High raw data throughput is achieved using a dedicated high speed data transfer device available for the VMEbus. The device can attain a raw data rate of 2.5 million coincidence events per second for raw events per second for raw events which are 64 bits wide. Real-time data acquisition and pre-processing requirements can be met by about forty 20 MHz Motorola 68020/68881 processors

  5. Implementation of 3D tomographic visualisation through planar ICT data from experimental gamma-ray tomographic system

    International Nuclear Information System (INIS)

    Umesh Kumar; Singh, Gursharan; Ravindran, V.R.

    2001-01-01

    Industrial Computed Tomography (ICT) is one of the latest methods of non-destructive testing and examination. Different prototypes of Computed Industrial Tomographic Imaging System (CITIS) have been developed and experimental data have been generated in Isotope Applications Division. The experimental gamma-rays based tomographic imaging system comprises of beam generator containing approx. 220 GBq (6 Curies) of 137 Cs, a single NaI(Tl) -PMT integral assembly in a thick shielding and associated electronics, stepper motor controlled mechanical manipulator, collimators and required software. CITIS data is normally acquired in one orientation of the sample. It may be sometimes required to view a tomographic plane in a different orientation. Also, 3D visualization may be required with the available 2D data set. All these can be achieved by processing the available data. We have customized some of the routines for this purpose provided IDL (Integrated Data Language) package to suit our requirements. The present paper discusses methodology adopted for this purpose with an illustrative example. (author)

  6. Design of signal reception and processing system of embedded ultrasonic endoscope

    Science.gov (United States)

    Li, Ming; Yu, Feng; Zhang, Ruiqiang; Li, Yan; Chen, Xiaodong; Yu, Daoyin

    2009-11-01

    Embedded Ultrasonic Endoscope, based on embedded microprocessor and embedded real-time operating system, sends a micro ultrasonic probe into coelom through the biopsy channel of the Electronic Endoscope to get the fault histology features of digestive organs by rotary scanning, and acquires the pictures of the alimentary canal mucosal surface. At the same time, ultrasonic signals are processed by signal reception and processing system, forming images of the full histology of the digestive organs. Signal Reception and Processing System is an important component of Embedded Ultrasonic Endoscope. However, the traditional design, using multi-level amplifiers and special digital processing circuits to implement signal reception and processing, is no longer satisfying the standards of high-performance, miniaturization and low power requirements that embedded system requires, and as a result of the high noise that multi-level amplifier brought, the extraction of small signal becomes hard. Therefore, this paper presents a method of signal reception and processing based on double variable gain amplifier and FPGA, increasing the flexibility and dynamic range of the Signal Reception and Processing System, improving system noise level, and reducing power consumption. Finally, we set up the embedded experiment system, using a transducer with the center frequency of 8MHz to scan membrane samples, and display the image of ultrasonic echo reflected by each layer of membrane, with a frame rate of 5Hz, verifying the correctness of the system.

  7. Efficiency of an automated reception and turnaround time management system for the phlebotomy room.

    Science.gov (United States)

    Yun, Soon Gyu; Shin, Jeong Won; Park, Eun Su; Bang, Hae In; Kang, Jung Gu

    2016-01-01

    Recent advances in laboratory information systems have largely been focused on automation. However, the phlebotomy services have not been completely automated. To address this issue, we introduced an automated reception and turnaround time (TAT) management system, for the first time in Korea, whereby the patient's information is transmitted directly to the actual phlebotomy site and the TAT for each phlebotomy step can be monitored at a glance. The GNT5 system (Energium Co., Ltd., Korea) was installed in June 2013. The automated reception and TAT management system has been in operation since February 2014. Integration of the automated reception machine with the GNT5 allowed for direct transmission of laboratory order information to the GNT5 without involving any manual reception step. We used the mean TAT from reception to actual phlebotomy as the parameter for evaluating the efficiency of our system. Mean TAT decreased from 5:45 min to 2:42 min after operationalization of the system. The mean number of patients in queue decreased from 2.9 to 1.0. Further, the number of cases taking more than five minutes from reception to phlebotomy, defined as the defect rate, decreased from 20.1% to 9.7%. The use of automated reception and TAT management system was associated with a decrease of overall TAT and an improved workflow at the phlebotomy room.

  8. Computerized tomographic system

    International Nuclear Information System (INIS)

    Godbarsen, R.; Barrett, D.M.; Garrott, P.M.; Foley, L.E.; Redington, R.W.; Lambert, T.W.; Edelheit, L.S.

    1981-01-01

    A computerized tomographic system for examining human breasts is described in detail. Conventional X-ray scanning apparatus has difficulty in achieving the levels of image definition and examination speeds required for mass screening. A novel method of scanning successive layers of the breast with a rotating X-ray beam is discussed and details of the control circuitry and sequence steps are given. The method involves immersing the breast in an inner fluid (e.g. water) filled container which is stationary during an examination and is surrounded by a large outer container which is also filled with the fluid; the inner and outer containers are always maintained at a constant height and the X-ray absorption across the fan-shaped beam is as close as possible to constant. (U.K.)

  9. Field experience with a mobile tomographic nondestructive assay system

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Betts, S.E.; Taggart, D.P.; Estep, R.J.; Nicholas, N.J.; Lucas, M.C.; Harlan, R.A.

    1995-01-01

    A mobile tomographic gamma-ray scanner (TGS) developed by Los Alamos National Laboratory was recently demonstrated at the Rocky Flats Environmental Technology Site and is currently in use at Los Alamos waste storage areas. The scanner was developed to assay radionuclides in low-level, transuranic, and mixed waste in containers ranging in size from 2 ft 3 boxes to 83-gallon overpacks. The tomographic imaging capability provides a complete correction for source distribution and matrix attenuation effects, enabling accurate assays of Pu-239 and other gamma-ray emitting isotopes. In addition, the system can reliably detect self-absorbing material such as plutonium metal shot, and can correct for bias caused by self-absorption. The system can be quickly configured to execute far-field scans, segmented gamma-ray scans, and a host of intermediate scanning protocols, enabling higher throughput (up to 20 drums per 8-hour shift). In this paper, we will report on the results of field trials of the mobile system at Rocky Flats and Los Alamos. Assay accuracy is confirmed for cases in which TGS assays can be compared with assays (e.g. with calorimetry) of individual packages within the drums. The mobile tomographic technology is expected to considerably reduce characterization costs at DOE production and environmental technology sites

  10. Tomographic evaluation of a dual-head positron emission tomography system

    International Nuclear Information System (INIS)

    Efthimiou, N; Maistros, S; Tripolitis, X; Panayiotakis, G; Samartzis, A; Loudos, G

    2011-01-01

    In this paper we present the performance evaluation results, in the planar and tomographic modes, of a low-cost positron emission tomography camera dedicated to small-animal imaging. The system consists of two pixelated Lu 2 SiO 5 crystals, two Hamamatsu H8500 position sensitive photomultiplier tubes, fast amplification electronics and an FPGA-USB-based read-out system. The parameters that have been studied are (i) saturation as a function of the head distance and photon acceptance angle, (ii) effect of the number of projections and half or complete head's rotation, (iii) spatial resolution as a function of the head distance, (iv) spatial resolution as a function of acceptance angle, (v) system's sensitivity as a function of these parameters and (vi) performance in small mice imaging. Image reconstruction has been carried out using open source software developed by our group (QSPECT), which is designed mainly for SPECT imaging. The results indicate that the system has a linear response for activities up to at least 2 MBq, which are typical in small-animal imaging. Best tomographic spatial resolution was measured to be ∼2 mm. The system has been found suitable for imaging of small mice both in the planar and tomographic modes

  11. Axial tomographic system for radiation diagnoses

    International Nuclear Information System (INIS)

    Crowther, T.J.

    1977-01-01

    The axial tomographic scanner consists of a source of hard radiation passing a fan shaped beam through a plane layer of the body under examination, a detector, and driving systems for the sequential displacement and rotation of the radiation source and the detector. The diagnosis is made by means of a data processing system offering extensive time overlap capability of the individual system functions. The data sets from transmission or absorption are processed in three independent subsystems, i.e., the scanning system, the processing system and the display system. The systems are made up of well-known modules, e.g., Nova 1200 or Eclipse 5200. Hence, as a result of the independent design of the data system, raw data will not be lost in case of faults in some subsystem. (DG) [de

  12. Tomographic reconstruction by using FPSIRT (Fast Particle System Iterative Reconstruction Technique)

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Icaro Valgueiro M.; Melo, Silvio de Barros; Dantas, Carlos; Lima, Emerson Alexandre; Silva, Ricardo Martins; Cardoso, Halisson Alberdan C., E-mail: ivmm@cin.ufpe.br, E-mail: sbm@cin.ufpe.br, E-mail: rmas@cin.ufpe.br, E-mail: hacc@cin.ufpe.br, E-mail: ccd@ufpe.br, E-mail: eal@cin.ufpe.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2015-07-01

    The PSIRT (Particle System Iterative Reconstruction Technique) is a method of tomographic image reconstruction primarily designed to work with configurations suitable for industrial applications. A particle system is an optimization technique inspired in real physical systems that associates to the reconstructing material a set of particles with certain physical features, subject to a force eld, which can produce movement. The system constantly updates the set of particles by repositioning them in such a way as to approach the equilibrium. The elastic potential along a trajectory is a function of the difference between the attenuation coefficient in the current configuration and the corresponding input data. PSIRT has been successfully used to reconstruct simulated and real objects subject to sets of parallel and fanbeam lines in different angles, representing typical gamma-ray tomographic arrangements. One of PSIRT's limitation was its performance, too slow for real time scenarios. In this work, it is presented a reformulation in PSIRT's computational model, which is able to grant the new algorithm, the FPSIRT - Fast System Iterative Reconstruction Technique, a performance up to 200-time faster than PSIRT's. In this work a comparison of their application to real and simulated data from the HSGT, High Speed Gamma Tomograph, is presented. (author)

  13. Tomographic reconstruction by using FPSIRT (Fast Particle System Iterative Reconstruction Technique)

    International Nuclear Information System (INIS)

    Moreira, Icaro Valgueiro M.; Melo, Silvio de Barros; Dantas, Carlos; Lima, Emerson Alexandre; Silva, Ricardo Martins; Cardoso, Halisson Alberdan C.

    2015-01-01

    The PSIRT (Particle System Iterative Reconstruction Technique) is a method of tomographic image reconstruction primarily designed to work with configurations suitable for industrial applications. A particle system is an optimization technique inspired in real physical systems that associates to the reconstructing material a set of particles with certain physical features, subject to a force eld, which can produce movement. The system constantly updates the set of particles by repositioning them in such a way as to approach the equilibrium. The elastic potential along a trajectory is a function of the difference between the attenuation coefficient in the current configuration and the corresponding input data. PSIRT has been successfully used to reconstruct simulated and real objects subject to sets of parallel and fanbeam lines in different angles, representing typical gamma-ray tomographic arrangements. One of PSIRT's limitation was its performance, too slow for real time scenarios. In this work, it is presented a reformulation in PSIRT's computational model, which is able to grant the new algorithm, the FPSIRT - Fast System Iterative Reconstruction Technique, a performance up to 200-time faster than PSIRT's. In this work a comparison of their application to real and simulated data from the HSGT, High Speed Gamma Tomograph, is presented. (author)

  14. Design and applications of Computed Industrial Tomographic Imaging System (CITIS)

    International Nuclear Information System (INIS)

    Ramakrishna, G.S.; Umesh Kumar; Datta, S.S.; Rao, S.M.

    1996-01-01

    Computed tomographic imaging is an advanced technique for nondestructive testing (NDT) and examination. For the first time in India a computed aided tomography system has been indigenously developed in BARC for testing industrial components and was successfully demonstrated. The system in addition to Computed Tomography (CT) can also perform Digital Radiography (DR) to serve as a powerful tool for NDT applications. It has wider applications in the fields of nuclear, space and allied fields. The authors have developed a computed industrial tomographic imaging system with Cesium 137 gamma radiation source for nondestructive examination of engineering and industrial specimens. This presentation highlights the design and development of a prototype system and its software for image reconstruction, simulation and display. The paper also describes results obtained with several tests specimens, current development and possibility of using neutrons as well as high energy x-rays in computed tomography. (author)

  15. Imaging MOSS tomographic system for H-1NF

    International Nuclear Information System (INIS)

    Glass, F.; Howard, J.

    1999-01-01

    A tomographic diagnostic utilising the Modulated Optical Solid-State spectrometer (MOSS) is planned for the H-1NF stellarator at the ANU. It is designed to create two-dimensional temperature or velocity maps of a poloidal cross-section of the high temperature plasma of H-1NF. The introduction of the MOSS spectrometers has enabled the development of several diagnostics to be used on the H-1NF stellerator. The MOSS spectrometer allows calculations of the plasma temperature and bulk velocity based on a line-integrated measurement of light emitted from electronic transitions within the plasma. A tomographic system utilising a rotatable multi-view ring apparatus and spatial multiplexing through a MOSS spectrometer is currently being developed. The ring apparatus is placed inside the H-1NF vessel and encircles the plasma. Multiple line-of-sight views collect light through a poloidal cross-section of the plasma and the emitted light is coupled into large core optical fibres. The transmitted light, via the optical fibre bundle, is then imaged through a large aperture MOSS spectrometer and onto another optical fibre array. Each fibre is then fed into a photomultiplier tube for signal detection. Characterisation of the properties of the lithium niobate (LiNbO 3 ) crystal used for modulation in the MOSS spectrometer is being undertaken to account for ray divergence in the imaging system. Tomographic techniques enable the construction of a temperature or velocity map of the poloidal cross-section. Rotating the ring apparatus to a new viewing position for the next pulse of plasma should allow an accurate picture to be built up based on the reproducibility of the plasma pulses. It is expected that initial testing of the system will begin in May when H-1NF begins operations at 0.5 Telsa field strength

  16. Development of a computerized tomographic system based on the FAN-BEAM technique

    International Nuclear Information System (INIS)

    Junqueira, M.M.; Santos, C.A.C.; Borges, J.C.

    1986-01-01

    The Nuclear Instrumentation Laboratory, at COPPE/UFRJ, concentrates its researches in the development of computerized tomographic systems, looking for applications in industrial and medical non destructive analysing techniques. In this work we have projected and constructed a tomographic prototype, based on the FAN-BEAM technique for irradiating the object under analysis. An algorithm previously developed to analyse parallel beams, was modified and adapted to the FAN-BEAM geometry. (Author) [pt

  17. The CDD system in computed tomographic diagnosis of diverticular disease

    International Nuclear Information System (INIS)

    Pustelnik, Daniel; Elsholtz, Fabian Henry Juergen; Hamm, Bernd; Niehues, Stefan Markus; Bojarski, Christian

    2017-01-01

    Purpose cation in computed tomographic diagnosis and briefly recapitulates its targeted advantages over preliminary systems. Primarily, application of the CDD in computed tomography diagnostics is described. Differences with respect to the categories of the older systems are pointed out on the level of each CDD type using imaging examples. The presented images are derived from our institute according to the S2k criteria. Literature was researched on PubMed. Results The CDD constitutes an improvement compared to older systems for categorizing the stages of diverticular disease. It provides more discriminatory power on the descriptive-morphological level and defines as well as differentiates more courses of the disease. Furthermore, the categories translate more directly into state-of-the-art decision-making concerning hospitalization and therapy. The CDD should be applied routinely in the computed tomographic diagnosis of diverticular disease. Typical imaging patterns are presented.

  18. Instability of the socio-economic systems as a factor of their receptivity towards changes

    Directory of Open Access Journals (Sweden)

    O. A. Romanova

    2010-09-01

    Full Text Available In this article author marks out the life phases of socio-economic systems from the point of view of theirs stability / instability, determines the correlation between life phase and receptivity degree of system to changes. They offer the order parameters of socio-economic system and assessment methods through which instability is conveyed. The suggested methods have been used for solving the problem of assessing the degree of receptivity of the regional economic systems to the currents global crisis and the following modernization process.

  19. Mobile 3D tomograph

    International Nuclear Information System (INIS)

    Illerhaus, Bernhard; Goebbels, Juergen; Onel, Yener; Sauerwein, Christoph

    2008-01-01

    Mobile tomographs often have the problem that high spatial resolution is impossible owing to the position or setup of the tomograph. While the tree tomograph developed by Messrs. Isotopenforschung Dr. Sauerwein GmbH worked well in practice, it is no longer used as the spatial resolution and measuring time are insufficient for many modern applications. The paper shows that the mechanical base of the method is sufficient for 3D CT measurements with modern detectors and X-ray tubes. CT measurements with very good statistics take less than 10 min. This means that mobile systems can be used, e.g. in examinations of non-transportable cultural objects or monuments. Enhancement of the spatial resolution of mobile tomographs capable of measuring in any position is made difficult by the fact that the tomograph has moving parts and will therefore have weight shifts. With the aid of tomographies whose spatial resolution is far higher than the mechanical accuracy, a correction method is presented for direct integration of the Feldkamp algorithm [de

  20. Precision tomographic analysis of reactor fuels

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Deok; Lee, Chang Hee; Kim, Jong Soo; Jeong, Jwong Hwan; Nam, Ki Yong

    2001-03-01

    For the tomographical assay, search of current status, analysis of neutron beam characteristics, MCNP code simulation, sim-fuel fabrication, neutron experiment for sim-fuel, multiaxes operation system design were done. In sensitivity simulation, the reconstruction results showed the good agreement. Also, the scoping test at ANL was very helpful for actual assay. Therefore, the results are applied for HANARO tomographical system setup and consecutive next research.

  1. Precision tomographic analysis of reactor fuels

    International Nuclear Information System (INIS)

    Lee, Yong Deok; Lee, Chang Hee; Kim, Jong Soo; Jeong, Jwong Hwan; Nam, Ki Yong

    2001-03-01

    For the tomographical assay, search of current status, analysis of neutron beam characteristics, MCNP code simulation, sim-fuel fabrication, neutron experiment for sim-fuel, multiaxes operation system design were done. In sensitivity simulation, the reconstruction results showed the good agreement. Also, the scoping test at ANL was very helpful for actual assay. Therefore, the results are applied for HANARO tomographical system setup and consecutive next research

  2. Emerging tomographic methods within the petroleum industry

    International Nuclear Information System (INIS)

    Johansen, Geir Anton

    2013-01-01

    Since industrial process tomography was introduced as a concept almost two decades ago, the considerable progress within a large variety of sensing modalities has to a large extent been technology driven. Industrial tomography applications may be divided into three categories: 1) Laboratory systems, 2) Field equipment for diagnostics and mapping purposes, and 3) Permanently installed systems. Examples on emerging methods on all categories will be presented, either from R and D at the University of Bergen and/or our industrial partners. Most developments are within the first category, where tomographs are used to provide better understanding of various processes such as pipe flow, separators, mixers and reactors. Here tomographic data is most often used to provide better process knowledge, for reference measurements and validation and development of process models, and finally for development for instruments and process equipment. The requirement here may be either high spatial resolution or high temporal resolution, or combinations of these. Tomographic field measurements are applied to either to inspect processes or equipment on a regular base or at faulty or irregular operation, or to map multicomponent systems such petroleum reservoirs, their structure and the distribution gas, oil and water within them. The latter will only be briefly touched upon here. Tomographic methods are increasingly being used for process and equipment diagnostics. The requirements vary and solutions based on repetition of single measurements, such as in column scanning, to full tomographic systems where there is sufficiently space or access. The third category is tomographic instruments that are permanently installed in situ in a process. These need not provide full tomographic images and instruments with fewer views are often preferred to reduce complexity and increase the instrument reliability. (author)

  3. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a tomographic scanning apparatus using a fan beam and digital output signal, and particularly to the design of the gas-pressurized ionization detection system. (U.K.)

  4. Beyond Reception

    DEFF Research Database (Denmark)

    This book argues that it is time to rethink reception as a traditional paradigm for understanding the relation between the ancient Greco-Roman traditions and early Judaism and Christianity. The concept of reception implies taking something from one fixed box into another, often a chronological...... intend to develop a more multi-faceted view of such precesses and to go beyond the term reception....

  5. Design and applications of Computed Industrial Tomographic Imaging System (CITIS)

    Energy Technology Data Exchange (ETDEWEB)

    Ramakrishna, G S; Kumar, Umesh; Datta, S S [Bhabha Atomic Research Centre, Bombay (India). Isotope Div.

    1994-12-31

    This paper highlights the design and development of a prototype Computed Tomographic (CT) imaging system and its software for image reconstruction, simulation and display. It also describes results obtained with several test specimens including Dhruva reactor uranium fuel assembly and possibility of using neutrons as well as high energy x-rays in computed tomography. 5 refs., 4 figs.

  6. ECAT: a new computerized tomographic imaging system for position-emitting radiopharmaceuticals

    International Nuclear Information System (INIS)

    Phelps, M.E.; Hoffman, E.J.; Huang, S.C.; Kuhl, D.E.

    1977-01-01

    The ECAT was designed and developed as a complete computerized positron radionuclide imaging system capable of providing high contrast, high resolution, quantitative images in 2 dimensional and tomographic formats. Flexibility, in its various image mode options, allows it to be used for a wide variety of imaging problems

  7. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus, with particular reference to the adjustable fan beam and its collimator system, together with the facility for taking a conventional x-radiograph without moving the patient. (U.K.)

  8. Simulation of Tomographic Reconstruction of Magnetosphere Plasma Distribution By Multi-spacecraft Systems.

    Science.gov (United States)

    Kunitsyn, V.; Nesterov, I.; Andreeva, E.; Zelenyi, L.; Veselov, M.; Galperin, Y.; Buchner, J.

    A satellite radiotomography method for electron density distributions was recently proposed for closely-space multi-spacecraft group of high-altitude satellites to study the physics of reconnection process. The original idea of the ROY project is to use a constellation of spacecrafts (one main and several sub-satellites) in order to carry out closely-spaced multipoint measurements and 2D tomographic reconstruction of elec- tron density in the space between the main satellite and the subsatellites. The distances between the satellites were chosen to vary from dozens to few hundreds of kilometers. The easiest data interpretation is achieved when the subsatellites are placed along the plasma streamline. Then, whenever a plasma density irregularity moves between the main satellite and the subsatellites it will be scanned in different directions and we can get 2D distribution of plasma using these projections. However in general sub- satellites are not placed exactly along the plasma streamline. The method of plasma velocity determination relative to multi-spacecraft systems is considered. Possibilities of 3D tomographic imaging using multi-spacecraft systems are analyzed. The model- ing has shown that efficient scheme for 3D tomographic imaging would be to place spacecrafts in different planes so that the angle between the planes would make not more then ten degrees. Work is supported by INTAS PROJECT 2000-465.

  9. Axial tomographic scanner

    International Nuclear Information System (INIS)

    1976-01-01

    An axial tomographic system is described comprising axial tomographic means for collecting sets of data corresponding to the transmission or absorption of a number of beams of penetrating radiation through a planar slice of an object. It includes means to locate an object to be analyzed, a source and detector for directing one or more beams of penetrating radiation through the object from the source to the detector, and means to rotate (and optionally translate) the source as well as means to process the collected sets of data. Data collection, data processing, and data display can each be conducted independently of each other. An additional advantage of the system described is that the raw data (i.e., the originally collected data) are not destroyed by the data processing but instead are retained intact for further reference or use, if needed

  10. Gamma Ray Tomographic Scan Method for Large Scale Industrial Plants

    International Nuclear Information System (INIS)

    Moon, Jin Ho; Jung, Sung Hee; Kim, Jong Bum; Park, Jang Geun

    2011-01-01

    The gamma ray tomography systems have been used to investigate a chemical process for last decade. There have been many cases of gamma ray tomography for laboratory scale work but not many cases for industrial scale work. Non-tomographic equipment with gamma-ray sources is often used in process diagnosis. Gamma radiography, gamma column scanning and the radioisotope tracer technique are examples of gamma ray application in industries. In spite of many outdoor non-gamma ray tomographic equipment, the most of gamma ray tomographic systems still remained as indoor equipment. But, as the gamma tomography has developed, the demand on gamma tomography for real scale plants also increased. To develop the industrial scale system, we introduced the gamma-ray tomographic system with fixed detectors and rotating source. The general system configuration is similar to 4 th generation geometry. But the main effort has been made to actualize the instant installation of the system for real scale industrial plant. This work would be a first attempt to apply the 4th generation industrial gamma tomographic scanning by experimental method. The individual 0.5-inch NaI detector was used for gamma ray detection by configuring circular shape around industrial plant. This tomographic scan method can reduce mechanical complexity and require a much smaller space than a conventional CT. Those properties make it easy to get measurement data for a real scale plant

  11. Tomographical properties of uniformly redundant arrays

    International Nuclear Information System (INIS)

    Cannon, T.M.; Fenimore, E.E.

    1978-01-01

    Recent work in coded aperture imaging has shown that the uniformly redundant array (URA) can image distant planar radioactive sources with no artifacts. The performance of two URA apertures when used in a close-up tomographic imaging system is investigated. It is shown that a URA based on m sequences is superior to one based on quadratic residues. The m sequence array not only produces less obnoxious artifacts in tomographic imaging, but is also more resilient to some described detrimental effects of close-up imaging. It is shown that in spite of these close-up effects, tomographic depth resolution increases as the source is moved closer to the detector

  12. A computational theory of visual receptive fields.

    Science.gov (United States)

    Lindeberg, Tony

    2013-12-01

    A receptive field constitutes a region in the visual field where a visual cell or a visual operator responds to visual stimuli. This paper presents a theory for what types of receptive field profiles can be regarded as natural for an idealized vision system, given a set of structural requirements on the first stages of visual processing that reflect symmetry properties of the surrounding world. These symmetry properties include (i) covariance properties under scale changes, affine image deformations, and Galilean transformations of space-time as occur for real-world image data as well as specific requirements of (ii) temporal causality implying that the future cannot be accessed and (iii) a time-recursive updating mechanism of a limited temporal buffer of the past as is necessary for a genuine real-time system. Fundamental structural requirements are also imposed to ensure (iv) mutual consistency and a proper handling of internal representations at different spatial and temporal scales. It is shown how a set of families of idealized receptive field profiles can be derived by necessity regarding spatial, spatio-chromatic, and spatio-temporal receptive fields in terms of Gaussian kernels, Gaussian derivatives, or closely related operators. Such image filters have been successfully used as a basis for expressing a large number of visual operations in computer vision, regarding feature detection, feature classification, motion estimation, object recognition, spatio-temporal recognition, and shape estimation. Hence, the associated so-called scale-space theory constitutes a both theoretically well-founded and general framework for expressing visual operations. There are very close similarities between receptive field profiles predicted from this scale-space theory and receptive field profiles found by cell recordings in biological vision. Among the family of receptive field profiles derived by necessity from the assumptions, idealized models with very good qualitative

  13. Central auditory neurons have composite receptive fields.

    Science.gov (United States)

    Kozlov, Andrei S; Gentner, Timothy Q

    2016-02-02

    High-level neurons processing complex, behaviorally relevant signals are sensitive to conjunctions of features. Characterizing the receptive fields of such neurons is difficult with standard statistical tools, however, and the principles governing their organization remain poorly understood. Here, we demonstrate multiple distinct receptive-field features in individual high-level auditory neurons in a songbird, European starling, in response to natural vocal signals (songs). We then show that receptive fields with similar characteristics can be reproduced by an unsupervised neural network trained to represent starling songs with a single learning rule that enforces sparseness and divisive normalization. We conclude that central auditory neurons have composite receptive fields that can arise through a combination of sparseness and normalization in neural circuits. Our results, along with descriptions of random, discontinuous receptive fields in the central olfactory neurons in mammals and insects, suggest general principles of neural computation across sensory systems and animal classes.

  14. Tomographic extreme-ultraviolet spectrographs: TESS.

    Science.gov (United States)

    Cotton, D M; Stephan, A; Cook, T; Vickers, J; Taylor, V; Chakrabarti, S

    2000-08-01

    We describe the system of Tomographic Extreme Ultraviolet (EUV) SpectrographS (TESS) that are the primary instruments for the Tomographic Experiment using Radiative Recombinative Ionospheric EUV and Radio Sources (TERRIERS) satellite. The spectrographs were designed to make high-sensitivity {80 counts/s)/Rayleigh [one Rayleigh is equivalent to 10(6) photons/(4pi str cm(2)s)}, line-of-sight measurements of the oi 135.6- and 91.1-nm emissions suitable for tomographic inversion. The system consists of five spectrographs, four identical nightglow instruments (for redundancy and added sensitivity), and one instrument with a smaller aperture to reduce sensitivity and increase spectral resolution for daytime operation. Each instrument has a bandpass of 80-140 nm with approximately 2- and 1-nm resolution for the night and day instruments, respectively. They utilize microchannel-plate-based two-dimensional imaging detectors with wedge-and-strip anode readouts. The instruments were designed, fabricated, and calibrated at Boston University, and the TERRIERS satellite was launched on 18 May 1999 from Vandenberg Air Force Base, California.

  15. A Mobile System for Music Anamnesis and Receptive Music Therapy in the Personal Home.

    Science.gov (United States)

    Denecke, Kerstin

    2017-01-01

    Receptive music therapy is active hearing of music that is specifically selected to cause a certain effect on a person, such as pain reduction, mental opening, confrontation etc. This active, guided hearing could be helpful as a supporting ritual for patients at home and could extend traditional therapy. However, patients are often unable to select the music pieces that might be helpful for them in a current situation. We are suggesting a self-learning decision support system that allows a patient to answer questions on music anamnesis, is ready for inclusion into an electronic health record, and which enables a therapist to compile a therapeutic music program for the patient at home. Beyond this, the system also suggests appropriate music and duration of listening based on the patient's reported current mental state. In this paper, a concept for such a mobile system for receptive music therapy will be proposed.

  16. Tomographic array

    International Nuclear Information System (INIS)

    1976-01-01

    A tomographic array with the following characteristics is described. An X-ray screen serving as detector is placed before a photomultiplier tube which itself is placed in front of a television camera connected to a set of image processors. The detector is concave towards the source and is replacable. Different images of the object are obtained simultaneously. Optical fibers and lenses are used for transmission within the system

  17. Predicting Volleyball Serve-Reception

    NARCIS (Netherlands)

    Paulo, Ana; Zaal, Frank T J M; Fonseca, Sofia; Araujo, Duarte

    2016-01-01

    Serve and serve-reception performance have predicted success in volleyball. Given the impact of serve-reception on the game, we aimed at understanding what it is in the serve and receiver's actions that determines the selection of the type of pass used in serve-reception and its efficacy. Four

  18. The CDD system in computed tomographic diagnosis of diverticular disease; Das CDD-System in der computertomografischen Diagnostik der Divertikelkrankheit

    Energy Technology Data Exchange (ETDEWEB)

    Pustelnik, Daniel; Elsholtz, Fabian Henry Juergen; Hamm, Bernd; Niehues, Stefan Markus [Charite - Universitaetsmedizin, Berlin (Germany). Inst. of Radiology; Bojarski, Christian [Charite - Universitaetsmedizin, Berlin (Germany). Div. of Gastroenterology, Infectiology and Rheumatology

    2017-08-15

    Purpose cation in computed tomographic diagnosis and briefly recapitulates its targeted advantages over preliminary systems. Primarily, application of the CDD in computed tomography diagnostics is described. Differences with respect to the categories of the older systems are pointed out on the level of each CDD type using imaging examples. The presented images are derived from our institute according to the S2k criteria. Literature was researched on PubMed. Results The CDD constitutes an improvement compared to older systems for categorizing the stages of diverticular disease. It provides more discriminatory power on the descriptive-morphological level and defines as well as differentiates more courses of the disease. Furthermore, the categories translate more directly into state-of-the-art decision-making concerning hospitalization and therapy. The CDD should be applied routinely in the computed tomographic diagnosis of diverticular disease. Typical imaging patterns are presented.

  19. Tomographic imaging system

    International Nuclear Information System (INIS)

    Hayakawa, T.; Horiba, I.; Kohno, H.; Nakaya, C.; Sekihara, K.; Shiono, H.; Tomura, T.; Yamamoto, S.; Yanaka, S.

    1980-01-01

    A tomographic imaging system comprising: irradiating means for irradating a cross-section of an object under consideration with radiation rays from plural directions; detector means for detecting the radiation rays transmitted through the cross-section of said object to produce an output signal; first memory means for storing the output signal of said detector means; and an image jreconstructing section for performing a convolution integral operation on the contents of said first memory means by means of a first weighting function to reconstruct a three-dimensional image of the cross-section of said object, said image reconstructing section including (I) second memory means for storing a second weighting function, said second weighting function being provided with a predetermined positive and negative (N-1)th order when the output signal of said detector means produced by the irradiation of the cross-section of said object from one of said plural directions is sampled by N points, the value of the (N-1)th order of said second weighting function being an integration of said first weighting function from the (N-1)th order to positive infinity and the value of -(N-1)th order of said second weighting function being an integration of said first weighting function from the -(N-1)th order to negative infinity, (II) control means for successively reading out the contents of said first and second memory means, and (III) operational means for performing multiplying and summing operations on the read-out contents of said first and second memory means, said operational means producing the product of the values fo the (N-1)th and -(N-1)th orders of said second weighting function and a component of the output signal of said detector means relating to the radiation rays free from the absorption thereof by said object

  20. A distributed multi-GPU system for high speed electron microscopic tomographic reconstruction.

    Science.gov (United States)

    Zheng, Shawn Q; Branlund, Eric; Kesthelyi, Bettina; Braunfeld, Michael B; Cheng, Yifan; Sedat, John W; Agard, David A

    2011-07-01

    Full resolution electron microscopic tomographic (EMT) reconstruction of large-scale tilt series requires significant computing power. The desire to perform multiple cycles of iterative reconstruction and realignment dramatically increases the pressing need to improve reconstruction performance. This has motivated us to develop a distributed multi-GPU (graphics processing unit) system to provide the required computing power for rapid constrained, iterative reconstructions of very large three-dimensional (3D) volumes. The participating GPUs reconstruct segments of the volume in parallel, and subsequently, the segments are assembled to form the complete 3D volume. Owing to its power and versatility, the CUDA (NVIDIA, USA) platform was selected for GPU implementation of the EMT reconstruction. For a system containing 10 GPUs provided by 5 GTX295 cards, 10 cycles of SIRT reconstruction for a tomogram of 4096(2) × 512 voxels from an input tilt series containing 122 projection images of 4096(2) pixels (single precision float) takes a total of 1845 s of which 1032 s are for computation with the remainder being the system overhead. The same system takes only 39 s total to reconstruct 1024(2) × 256 voxels from 122 1024(2) pixel projections. While the system overhead is non-trivial, performance analysis indicates that adding extra GPUs to the system would lead to steadily enhanced overall performance. Therefore, this system can be easily expanded to generate superior computing power for very large tomographic reconstructions and especially to empower iterative cycles of reconstruction and realignment. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Computerized tomographic in non-destructive testing

    International Nuclear Information System (INIS)

    Lopes, R.T.

    1988-01-01

    The process of computerized tomography has been developed for medical imaging purposes using tomographs with X-ray, and little attention has been given to others possibles applications of technique, because of its cost. As an alternative for the problem, we constructed a Tomographic System (STAC-1), using gamma-rays, for nonmedical applications. In this work we summarize the basic theory of reconstructing images using computerized tomography and we describe the considerations leading to the development of the experimental system. The method of reconstruction image implanted in the system is the filtered backprojection or convolution, with a digital filters system to carried on a pre-filtering in the projections. The experimental system is described, with details of control and the data processing. An alternative and a complementary system, using film as a detector is shown in preliminary form . This thesis discuss and shows the theorical and practical aspects, considered in the construction of the STAC-1, and also its limitations and apllications [pt

  2. Structural Modifications for Torsional Vibration Control of Shafting Systems Based on Torsional Receptances

    Directory of Open Access Journals (Sweden)

    Zihao Liu

    2016-01-01

    Full Text Available Torsional vibration of shafts is a very important problem in engineering, in particular in ship engines and aeroengines. Due to their high levels of integration and complexity, it is hard to get their accurate structural data or accurate modal data. This lack of data is unhelpful to vibration control in the form of structural modifications. Besides, many parts in shaft systems are not allowed to be modified such as rotary inertia of a pump or an engine, which is designed for achieving certain functions. This paper presents a strategy for torsional vibration control of shaft systems in the form of structural modifications based on receptances, which does not need analytical or modal models of the systems under investigation. It only needs the torsional receptances of the system, which can be obtained by testing simple auxiliary structure attached to relevant locations of the shaft system and using the finite element model (FEM of the simple structure. An optimization problem is constructed to determine the required structural modifications, based on the actual requirements of modal frequencies and mode shapes. A numerical experiment is set up and the influence of several system parameters is analysed. Several scenarios of constraints in practice are considered. The numerical simulation results demonstrate the effectiveness of this method and its feasibility in solving torsional vibration problems in practice.

  3. Industrial dynamic tomographic reconstruction

    International Nuclear Information System (INIS)

    Oliveira, Eric Ferreira de

    2016-01-01

    The state of the art methods applied to industrial processes is currently based on the principles of classical tomographic reconstructions developed for tomographic patterns of static distributions, or is limited to cases of low variability of the density distribution function of the tomographed object. Noise and motion artifacts are the main problems caused by a mismatch in the data from views acquired in different instants. All of these add to the known fact that using a limited amount of data can result in the presence of noise, artifacts and some inconsistencies with the distribution under study. One of the objectives of the present work is to discuss the difficulties that arise from implementing reconstruction algorithms in dynamic tomography that were originally developed for static distributions. Another objective is to propose solutions that aim at reducing a temporal type of information loss caused by employing regular acquisition systems to dynamic processes. With respect to dynamic image reconstruction it was conducted a comparison between different static reconstruction methods, like MART and FBP, when used for dynamic scenarios. This comparison was based on a MCNPx simulation as well as an analytical setup of an aluminum cylinder that moves along the section of a riser during the process of acquisition, and also based on cross section images from CFD techniques. As for the adaptation of current tomographic acquisition systems for dynamic processes, this work established a sequence of tomographic views in a just-in-time fashion for visualization purposes, a form of visually disposing density information as soon as it becomes amenable to image reconstruction. A third contribution was to take advantage of the triple color channel necessary to display colored images in most displays, so that, by appropriately scaling the acquired values of each view in the linear system of the reconstruction, it was possible to imprint a temporal trace into the regularly

  4. A distributed multi-GPU system for high speed electron microscopic tomographic reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Shawn Q.; Branlund, Eric; Kesthelyi, Bettina; Braunfeld, Michael B.; Cheng, Yifan; Sedat, John W. [The Howard Hughes Medical Institute and the W.M. Keck Advanced Microscopy Laboratory, Department of Biochemistry and Biophysics, University of California, San Francisco, 600, 16th Street, Room S412D, CA 94158-2517 (United States); Agard, David A., E-mail: agard@msg.ucsf.edu [The Howard Hughes Medical Institute and the W.M. Keck Advanced Microscopy Laboratory, Department of Biochemistry and Biophysics, University of California, San Francisco, 600, 16th Street, Room S412D, CA 94158-2517 (United States)

    2011-07-15

    Full resolution electron microscopic tomographic (EMT) reconstruction of large-scale tilt series requires significant computing power. The desire to perform multiple cycles of iterative reconstruction and realignment dramatically increases the pressing need to improve reconstruction performance. This has motivated us to develop a distributed multi-GPU (graphics processing unit) system to provide the required computing power for rapid constrained, iterative reconstructions of very large three-dimensional (3D) volumes. The participating GPUs reconstruct segments of the volume in parallel, and subsequently, the segments are assembled to form the complete 3D volume. Owing to its power and versatility, the CUDA (NVIDIA, USA) platform was selected for GPU implementation of the EMT reconstruction. For a system containing 10 GPUs provided by 5 GTX295 cards, 10 cycles of SIRT reconstruction for a tomogram of 4096{sup 2}x512 voxels from an input tilt series containing 122 projection images of 4096{sup 2} pixels (single precision float) takes a total of 1845 s of which 1032 s are for computation with the remainder being the system overhead. The same system takes only 39 s total to reconstruct 1024{sup 2}x256 voxels from 122 1024{sup 2} pixel projections. While the system overhead is non-trivial, performance analysis indicates that adding extra GPUs to the system would lead to steadily enhanced overall performance. Therefore, this system can be easily expanded to generate superior computing power for very large tomographic reconstructions and especially to empower iterative cycles of reconstruction and realignment. -- Highlights: {yields} A distributed multi-GPU system has been developed for electron microscopic tomography (EMT). {yields} This system allows for rapid constrained, iterative reconstruction of very large volumes. {yields} This system can be easily expanded to generate superior computing power for large-scale iterative EMT realignment.

  5. A distributed multi-GPU system for high speed electron microscopic tomographic reconstruction

    International Nuclear Information System (INIS)

    Zheng, Shawn Q.; Branlund, Eric; Kesthelyi, Bettina; Braunfeld, Michael B.; Cheng, Yifan; Sedat, John W.; Agard, David A.

    2011-01-01

    Full resolution electron microscopic tomographic (EMT) reconstruction of large-scale tilt series requires significant computing power. The desire to perform multiple cycles of iterative reconstruction and realignment dramatically increases the pressing need to improve reconstruction performance. This has motivated us to develop a distributed multi-GPU (graphics processing unit) system to provide the required computing power for rapid constrained, iterative reconstructions of very large three-dimensional (3D) volumes. The participating GPUs reconstruct segments of the volume in parallel, and subsequently, the segments are assembled to form the complete 3D volume. Owing to its power and versatility, the CUDA (NVIDIA, USA) platform was selected for GPU implementation of the EMT reconstruction. For a system containing 10 GPUs provided by 5 GTX295 cards, 10 cycles of SIRT reconstruction for a tomogram of 4096 2 x512 voxels from an input tilt series containing 122 projection images of 4096 2 pixels (single precision float) takes a total of 1845 s of which 1032 s are for computation with the remainder being the system overhead. The same system takes only 39 s total to reconstruct 1024 2 x256 voxels from 122 1024 2 pixel projections. While the system overhead is non-trivial, performance analysis indicates that adding extra GPUs to the system would lead to steadily enhanced overall performance. Therefore, this system can be easily expanded to generate superior computing power for very large tomographic reconstructions and especially to empower iterative cycles of reconstruction and realignment. -- Highlights: → A distributed multi-GPU system has been developed for electron microscopic tomography (EMT). → This system allows for rapid constrained, iterative reconstruction of very large volumes. → This system can be easily expanded to generate superior computing power for large-scale iterative EMT realignment.

  6. Health Challenges in Refugee Reception: Dateline Europe 2016.

    Science.gov (United States)

    Blitz, Brad K; d'Angelo, Alessio; Kofman, Eleonore; Montagna, Nicola

    2017-11-30

    The arrival of more than one million migrants, many of them refugees, has proved a major test for the European Union. Although international relief and monitoring agencies have been critical of makeshift camps in Calais and Eidomeni where infectious disease and overcrowding present major health risks, few have examined the nature of the official reception system and its impact on health delivery. Drawing upon research findings from an Economic and Social Research Council (ESRC) funded project, this article considers the physical and mental health of asylum-seekers in transit and analyses how the closure of borders has engendered health risks for populations in recognised reception centres in Sicily and in Greece. Data gathered by means of a survey administered in Greece (300) and in Sicily (400), and complemented by in-depth interviews with migrants (45) and key informants (50) including representatives of government offices, humanitarian and relief agencies, NGOs and activist organisations, are presented to offer an analysis of the reception systems in the two frontline states. We note that medical provision varies significantly from one centre to another and that centre managers play a critical role in the transmission of vital information. A key finding is that, given such disparity, the criteria used by the UNHCR to grade health services reception do not address the substantive issue that prevent refugees from accessing health services, even when provided on site. Health provision is not as recorded in UNHCR reporting but rather there are critical gaps between provision, awareness, and access for refugees in reception systems in Sicily and in Greece. This article concludes that there is a great need for more information campaigns to direct refugees to essential services.

  7. Reception research 2.0

    DEFF Research Database (Denmark)

    Mathieu, David

    Some might argue that reception analysis is a remnant of the past in an age where “people formerly known as the audience” (Rosen, 2006) are producing and circulating content on a diversity of interactive and participatory media platforms. Far from being the case, reception research must continue......, which appears increasingly complex, multi-formed and integrated to the audience. The original dimensions of Schrøder’s model need to be looked at with reference to both reception and circulation (Jenkins et al., 2013), and to the network that binds participatory media culture. It appears that with media...... 2.0, phenomena which traditionally fell under the labels of interpretation or reception are increasingly taking part in the media text itself. As audiences become textual matters, they contribute to set a new agenda for media research....

  8. Health Challenges in Refugee Reception: Dateline Europe 2016

    Science.gov (United States)

    Blitz, Brad K.; d’Angelo, Alessio; Kofman, Eleonore; Montagna, Nicola

    2017-01-01

    The arrival of more than one million migrants, many of them refugees, has proved a major test for the European Union. Although international relief and monitoring agencies have been critical of makeshift camps in Calais and Eidomeni where infectious disease and overcrowding present major health risks, few have examined the nature of the official reception system and its impact on health delivery. Drawing upon research findings from an Economic and Social Research Council (ESRC) funded project, this article considers the physical and mental health of asylum–seekers in transit and analyses how the closure of borders has engendered health risks for populations in recognised reception centres in Sicily and in Greece. Data gathered by means of a survey administered in Greece (300) and in Sicily (400), and complemented by in-depth interviews with migrants (45) and key informants (50) including representatives of government offices, humanitarian and relief agencies, NGOs and activist organisations, are presented to offer an analysis of the reception systems in the two frontline states. We note that medical provision varies significantly from one centre to another and that centre managers play a critical role in the transmission of vital information. A key finding is that, given such disparity, the criteria used by the UNHCR to grade health services reception do not address the substantive issue that prevent refugees from accessing health services, even when provided on site. Health provision is not as recorded in UNHCR reporting but rather there are critical gaps between provision, awareness, and access for refugees in reception systems in Sicily and in Greece. This article concludes that there is a great need for more information campaigns to direct refugees to essential services. PMID:29189766

  9. Health Challenges in Refugee Reception: Dateline Europe 2016

    Directory of Open Access Journals (Sweden)

    Brad K. Blitz

    2017-11-01

    Full Text Available The arrival of more than one million migrants, many of them refugees, has proved a major test for the European Union. Although international relief and monitoring agencies have been critical of makeshift camps in Calais and Eidomeni where infectious disease and overcrowding present major health risks, few have examined the nature of the official reception system and its impact on health delivery. Drawing upon research findings from an Economic and Social Research Council (ESRC funded project, this article considers the physical and mental health of asylum–seekers in transit and analyses how the closure of borders has engendered health risks for populations in recognised reception centres in Sicily and in Greece. Data gathered by means of a survey administered in Greece (300 and in Sicily (400, and complemented by in-depth interviews with migrants (45 and key informants (50 including representatives of government offices, humanitarian and relief agencies, NGOs and activist organisations, are presented to offer an analysis of the reception systems in the two frontline states. We note that medical provision varies significantly from one centre to another and that centre managers play a critical role in the transmission of vital information. A key finding is that, given such disparity, the criteria used by the UNHCR to grade health services reception do not address the substantive issue that prevent refugees from accessing health services, even when provided on site. Health provision is not as recorded in UNHCR reporting but rather there are critical gaps between provision, awareness, and access for refugees in reception systems in Sicily and in Greece. This article concludes that there is a great need for more information campaigns to direct refugees to essential services.

  10. Advances in tomographic PIV

    NARCIS (Netherlands)

    Novara, M.

    2013-01-01

    This research deals with advanced developments in 3D particle image velocimetry based on the tomographic PIV technique (Tomo-PIV). The latter is a relatively recent measurement technique introduced by Elsinga et al. in 2005, which is based on the tomographic reconstruction of particle tracers in

  11. Prediction of turning stability using receptance coupling

    Science.gov (United States)

    Jasiewicz, Marcin; Powałka, Bartosz

    2018-01-01

    This paper presents an issue of machining stability prediction of dynamic "lathe - workpiece" system evaluated using receptance coupling method. Dynamic properties of the lathe components (the spindle and the tailstock) are assumed to be constant and can be determined experimentally based on the results of the impact test. Hence, the variable of the system "machine tool - holder - workpiece" is the machined part, which can be easily modelled analytically. The method of receptance coupling enables a synthesis of experimental (spindle, tailstock) and analytical (machined part) models, so impact testing of the entire system becomes unnecessary. The paper presents methodology of analytical and experimental models synthesis, evaluation of the stability lobes and experimental validation procedure involving both the determination of the dynamic properties of the system and cutting tests. In the summary the experimental verification results would be presented and discussed.

  12. Expediting model-based optoacoustic reconstructions with tomographic symmetries

    International Nuclear Information System (INIS)

    Lutzweiler, Christian; Deán-Ben, Xosé Luís; Razansky, Daniel

    2014-01-01

    Purpose: Image quantification in optoacoustic tomography implies the use of accurate forward models of excitation, propagation, and detection of optoacoustic signals while inversions with high spatial resolution usually involve very large matrices, leading to unreasonably long computation times. The development of fast and memory efficient model-based approaches represents then an important challenge to advance on the quantitative and dynamic imaging capabilities of tomographic optoacoustic imaging. Methods: Herein, a method for simplification and acceleration of model-based inversions, relying on inherent symmetries present in common tomographic acquisition geometries, has been introduced. The method is showcased for the case of cylindrical symmetries by using polar image discretization of the time-domain optoacoustic forward model combined with efficient storage and inversion strategies. Results: The suggested methodology is shown to render fast and accurate model-based inversions in both numerical simulations andpost mortem small animal experiments. In case of a full-view detection scheme, the memory requirements are reduced by one order of magnitude while high-resolution reconstructions are achieved at video rate. Conclusions: By considering the rotational symmetry present in many tomographic optoacoustic imaging systems, the proposed methodology allows exploiting the advantages of model-based algorithms with feasible computational requirements and fast reconstruction times, so that its convenience and general applicability in optoacoustic imaging systems with tomographic symmetries is anticipated

  13. Integrated parallel reception, excitation, and shimming (iPRES).

    Science.gov (United States)

    Han, Hui; Song, Allen W; Truong, Trong-Kha

    2013-07-01

    To develop a new concept for a hardware platform that enables integrated parallel reception, excitation, and shimming. This concept uses a single coil array rather than separate arrays for parallel excitation/reception and B0 shimming. It relies on a novel design that allows a radiofrequency current (for excitation/reception) and a direct current (for B0 shimming) to coexist independently in the same coil. Proof-of-concept B0 shimming experiments were performed with a two-coil array in a phantom, whereas B0 shimming simulations were performed with a 48-coil array in the human brain. Our experiments show that individually optimized direct currents applied in each coil can reduce the B0 root-mean-square error by 62-81% and minimize distortions in echo-planar images. The simulations show that dynamic shimming with the 48-coil integrated parallel reception, excitation, and shimming array can reduce the B0 root-mean-square error in the prefrontal and temporal regions by 66-79% as compared with static second-order spherical harmonic shimming and by 12-23% as compared with dynamic shimming with a 48-coil conventional shim array. Our results demonstrate the feasibility of the integrated parallel reception, excitation, and shimming concept to perform parallel excitation/reception and B0 shimming with a unified coil system as well as its promise for in vivo applications. Copyright © 2013 Wiley Periodicals, Inc.

  14. Means for controlling operation of power sources associated with an axial tomographic system

    International Nuclear Information System (INIS)

    1976-01-01

    An axial tomographic system is described having scanner means normally in an off-condition where all associated power sources are electrically isolated from the units driven thereby. It also includes means for activating the scanner means to establish an on-condition, control means including means to measure one or more system parameters when the scanner means is in an on-condition and to determine if the measured parameters are within predetermined limits, and means for maintaining the on-condition only if the control means is properly operational and all measured system parameters are within the predetermined limits

  15. Receptive processer og IT

    DEFF Research Database (Denmark)

    Ambjørn, Lone

    2002-01-01

    Sproglæringsteoretisk værktøj til udvikling af IT-støttede materialer og programmer inden for sproglig reception......Sproglæringsteoretisk værktøj til udvikling af IT-støttede materialer og programmer inden for sproglig reception...

  16. Invocation Receptivity in Female of Rabbit

    Directory of Open Access Journals (Sweden)

    Martin Fik

    2017-05-01

    Full Text Available The target of this work was verified effect of transport females in the car for advance state of receptivity in young females broiler rabbits. We used nulliparous females of broiler hybrid HYCOLE (age 4-5 months, weight 3.5-3.8 kg. Experiment was realizated twice. First in half of November (31 females, second in half of February (32 females. Females was layed individually in boxes. After they were transported by car 1 hour (50 km. Before and after experiment we detected state of receptivity in females with coloration of vulva. The state of receptivity was determited from 1 for 4 colour of vulva. ( 1 – anemic coloration of vulva, 2- pink, 3 – red, 4- violet. We detected positive state of transport, on the receptivity. In November before transport was average of receptivity 1.87, after transport 2.25. The state of receptivity will be improve in 12 females (38.71 %. Improve from 1 to 2 was detected in 4 females, from 2 to 3 in 8 females. Improved from 2 to 4 , or from 3 to 4 wasn´t noticed in this group. The state of receptivity wasn´t changed in 19 females (61.29 %. In the state of receptivity 1 stayed 2 females, in the state 2 stayed 15 females, in the state 3 stayed 2 females and in the state 4 wasn´t any female. In February after the end of experiment, state of receptivity was improved with transport in the car from 2.19 to 2.65. The state of receptivity was improved in 13 females  (40.63 %.  Improve from 1 to 2 we detected in 1 female, from 2 to 3 we detected in 8 females, from 2 to 4 we detected in 2 females, from 3 to 4 in 2 females. In 19 females (59.38% we don´t noticed change state of receptivity. In the state of receptivity 1 were 2 females, in 2 were 11 females, in 3 were 5 females, in 4 was 1 female.

  17. Measuring receptive collocational competence across proficiency ...

    African Journals Online (AJOL)

    The present study investigates (i) English as Foreign Language (EFL) learners' receptive collocational knowledge growth in relation to their linguistic proficiency level; (ii) how much receptive collocational knowledge is acquired as linguistic proficiency develops; and (iii) the extent to which receptive knowledge of ...

  18. Cardiac imaging systems and methods employing computerized tomographic scanning

    International Nuclear Information System (INIS)

    Richey, J.B.; Wake, R.H.; Walters, R.G.; Hunt, W.F.; Cool, S.L.

    1980-01-01

    The invention relates to cardiac imaging systems and methods employing computerised tomographic scanning. Apparatus is described which allows an image of the radiation attenuation of the heart at a desired phase of the cardiac cycle. The patients ECG signal can be used in a transverse-and-rotate type CT scanner as a time base, so that the beam reaches the heart at a desired phase of the cardiac cycle, or, in a purely rotational-type CT scanner continuously generated scan data is only stored for corresponding phases of successive cardiac cycles. Alternatively, gating of the beams themselves by shuttering or switching the power supply can be controlled by the ECG signal. A pacemaker is used to stabilize the cardiac period. Also used is a system for recognising unacceptable variations in the cardiac period and discarding corresponding scan data. In a transverse-and-rotate type fan-beam CT scanner, the effective beam width is narrowed to reduce the duration of the traverse of the heart. (U.K.)

  19. Learning receptive fields using predictive feedback.

    Science.gov (United States)

    Jehee, Janneke F M; Rothkopf, Constantin; Beck, Jeffrey M; Ballard, Dana H

    2006-01-01

    Previously, it was suggested that feedback connections from higher- to lower-level areas carry predictions of lower-level neural activities, whereas feedforward connections carry the residual error between the predictions and the actual lower-level activities [Rao, R.P.N., Ballard, D.H., 1999. Nature Neuroscience 2, 79-87.]. A computational model implementing the hypothesis learned simple cell receptive fields when exposed to natural images. Here, we use predictive feedback to explain tuning properties in medial superior temporal area (MST). We implement the hypothesis using a new, biologically plausible, algorithm based on matching pursuit, which retains all the features of the previous implementation, including its ability to efficiently encode input. When presented with natural images, the model developed receptive field properties as found in primary visual cortex. In addition, when exposed to visual motion input resulting from movements through space, the model learned receptive field properties resembling those in MST. These results corroborate the idea that predictive feedback is a general principle used by the visual system to efficiently encode natural input.

  20. Three dimensional reconstruction of tomographic images of the retina

    International Nuclear Information System (INIS)

    Glittenberg, C.; Zeiler, F.; Falkner, C.; Binder, S.; Povazay, B.; Hermann, B.; Drexler, W.

    2007-01-01

    The development of a new display system for the three-dimensional visualization of tomographic images in ophthalmology. Specifically, a system that can use stacks of B-mode scans from an ultrahigh resolution optical tomography examination to vividly display retinal specimens as three-dimensional objects. Several subroutines were programmed in the rendering and raytracing program Cinema 4D XL 9.102 Studio Bundle (Maxon Computer Inc., Friedrichsburg, Germany), which could process stacks of tomographic scans into three-dimensional objects. Ultrahigh resolution optical coherence tomography examinations were performed on patients with various retinal pathologies and post processed with the subroutines that had been designed. All ultrahigh resolution optical coherence tomographies were performed with a titanium: sapphire based ultra broad bandwidth (160 nm) femtosecond laser system (INTEGRAL, Femtolasers Productions GmbH. Vienna Austria) with an axial resolution of 3 μm. A new three dimensional display system for tomographic images in ophthalmology was developed, which allows a highly vivid display of physiological and pathological structures of the retina. The system also distinguishes itself through its high interactivity and adaptability. This new display system allows the visualization of physiological and pathological structures of the retina in a new way, which will give us new insight into their morphology and development. (author) [de

  1. Comparative study of the macroscopic finding, conventional tomographic imaging, and computed tomographic imaging in locating the mandibular canal

    International Nuclear Information System (INIS)

    Choi, Hang Moon; You, Dong Soo

    1995-01-01

    The purpose of this study was comparison of conventional tomography with reformatted computed tomography for dental implant in locating the mandibular canal. Five dogs were used and after conventional tomographs and fitted computed tomographs were taken, four dentist traced all films. Mandibles were sectioned with 2 mm slice thickness and the sections were then radiographed (contact radiography). Each radiograpic image was traced and linear measurements were made from mandibular canal to alveolar crest, buccal cortex, lingual cortex, and inferior border. The following results were obtained; 1. Reformatted computed tomographs were exacter than conventional tomography by alveolar crest to canal length of -0.6 mm difference between real values and radiographs 2. The average measurements of buccal cortex to mandibular canal width and lingual cortex to mandibular canal width of conventional tomographs were exacter than reformatted computed tomographs, but standard deviations were higher than reformatted computed tomographs. 3. Standard deviations of reformatted computed tomographs were lower than conventional tomographs at all comparing sites 4. At reformatted computed tomography 62.5% of the measurements performed were within ±1 mm of the true value, and at conventional tomography 24.1% were. 5. Mandibular canal invisibility was 0.8% at reformatted computed tomography and 9.2% at conventional tomography. Reformatted computed tomography has been shown to be more useful radiographic technique for assessment of the mandibular canal than conventional tomography.

  2. Transducer project and optimization of the ultra low magnetic field NMR tomograph reception system system; Projeto de transdutores e otimizacao do sistema de recepcao do tomografo de RMN de campo magnetico ultra baixo

    Energy Technology Data Exchange (ETDEWEB)

    Vidoto, Edson Luiz Gea

    1995-12-31

    The aim of the present work was to optimize the signal to noise ratio in our NMR imaging system (TORM 005) by improving transducer`s reception quality through better designed coils, balanced tuning circuit for this coils and power decoupling circuits and by reducing interference from the electromagnetic environment. For this purpose, we had to modify the internal electromagnetic shielding and incorporate line filters in the more critical signals paths. Also, new types of coils were developed, improving the signal to noise ratio, and allowing us to make clinical exams with superior quality for several anatomies. Balanced circuits for tuning and matching of the coil were studied and built, allowing a reduction of the coil losses because patient`s load. This produced a more reliable coil tuning after positioning each new patient. Circuits to avoid the receiver input overload and decoupling circuits for the isolation of receiver coils from excitation coil were designed and incorporated to the TORM 005. All these alterations of our imaging system (TORM 005) contributed to a significant improvement in the signal to noise ratio, reliability and reproducibility of the system. This permitted to operate the system routinely for clinical applications, research and development in the area of ultra low magnetic field tomography. (author) 46 refs., 66 figs., 11 tabs.

  3. Transducer project and optimization of the ultra low magnetic field NMR tomograph reception system system; Projeto de transdutores e otimizacao do sistema de recepcao do tomografo de RMN de campo magnetico ultra baixo

    Energy Technology Data Exchange (ETDEWEB)

    Vidoto, Edson Luiz Gea

    1996-12-31

    The aim of the present work was to optimize the signal to noise ratio in our NMR imaging system (TORM 005) by improving transducer`s reception quality through better designed coils, balanced tuning circuit for this coils and power decoupling circuits and by reducing interference from the electromagnetic environment. For this purpose, we had to modify the internal electromagnetic shielding and incorporate line filters in the more critical signals paths. Also, new types of coils were developed, improving the signal to noise ratio, and allowing us to make clinical exams with superior quality for several anatomies. Balanced circuits for tuning and matching of the coil were studied and built, allowing a reduction of the coil losses because patient`s load. This produced a more reliable coil tuning after positioning each new patient. Circuits to avoid the receiver input overload and decoupling circuits for the isolation of receiver coils from excitation coil were designed and incorporated to the TORM 005. All these alterations of our imaging system (TORM 005) contributed to a significant improvement in the signal to noise ratio, reliability and reproducibility of the system. This permitted to operate the system routinely for clinical applications, research and development in the area of ultra low magnetic field tomography. (author) 46 refs., 66 figs., 11 tabs.

  4. Carrier phase synchronization system for improved amplitude modulation and television broadcast reception

    Science.gov (United States)

    Smith, Stephen F [Loudon, TN; Moore, James A [Powell, TN

    2009-09-08

    Systems and methods are described for carrier phase synchronization for improved AM and TV broadcast reception. A method includes synchronizing the phase of a carrier frequency of a broadcast signal with the phase of a remote reference frequency. An apparatus includes a receiver to detect the phase of a reference signal; a phase comparator coupled to the reference signal-phase receiver; a voltage controlled oscillator coupled to the phase comparator; and a phase-controlled radio frequency output coupled to the voltage controlled oscillator.

  5. Photon emission tomographic apparatus and method

    International Nuclear Information System (INIS)

    Blum, A.S.

    1983-01-01

    Tomographic imaging system employs large area, collimated scintillation detector rotated around radiation emitting subject. Detector support rotates with an inner ring inside a stationary outer ring. Counterbalanced detector support arm is forced by spring action to cause collimator face to follow body contour as detector rotates around the body, thereby reducing collimator to subject distance to improve system resolution. Includes adjustable subject support system

  6. The thalamo-cortical auditory receptive fields: regulation by the states of vigilance, learning and the neuromodulatory systems.

    Science.gov (United States)

    Edeline, Jean-Marc

    2003-12-01

    The goal of this review is twofold. First, it aims to describe the dynamic regulation that constantly shapes the receptive fields (RFs) and maps in the thalamo-cortical sensory systems of undrugged animals. Second, it aims to discuss several important issues that remain unresolved at the intersection between behavioral neurosciences and sensory physiology. A first section presents the RF modulations observed when an undrugged animal spontaneously shifts from waking to slow-wave sleep or to paradoxical sleep (also called REM sleep). A second section shows that, in contrast with the general changes described in the first section, behavioral training can induce selective effects which favor the stimulus that has acquired significance during learning. A third section reviews the effects triggered by two major neuromodulators of the thalamo-cortical system--acetylcholine and noradrenaline--which are traditionally involved both in the switch of vigilance states and in learning experiences. The conclusion argues that because the receptive fields and maps of an awake animal are continuously modulated from minute to minute, learning-induced sensory plasticity can be viewed as a "crystallization" of the receptive fields and maps in one of the multiple possible states. Studying the interplays between neuromodulators can help understanding the neurobiological foundations of this dynamic regulation.

  7. Bruce X Longwood television reception survey

    International Nuclear Information System (INIS)

    Hatanaka, G.K.

    1992-01-01

    Property owners living close to a proposed 500-kV transmission line route in Ontario expressed concerns that the line would affect their television reception. To give a reasonable evaluation of the impact of the transmission line, tests were conducted before and after installation of the line in which the possibility of active or passive interference to reception was assessed. Measurements were made of signal strength and ambient noise, and television reception was also recorded on videotape. Possible transmission line effects due to radiated noise, signal reduction, and ghosts are analyzed. The analysis of signal and noise conditions, and the assessment of videotaped reception, provide reasonable evidence that the line has had negligible impact on the television reception along the line route. 13 refs., 18 figs., 12 tabs

  8. A Methodology for Conus APOE Reception Planning.

    Science.gov (United States)

    1982-09-01

    mentioned, the reception process is a service-type system, which produces services to be rendered to the personnel and cargo flowing through it. The... Heizer , Ramon N. Chief, Supply Systems Branch, Dir- ectorate of Distribution, DCS/Logistics Operations, HQ AFLC, Wright-Patterson AFB OH. Personal inter

  9. Conceptual design of the tomographic system for simultaneous studying of soft and hard X-ray emission from dense magnetized plasma

    Energy Technology Data Exchange (ETDEWEB)

    Bielecki, J., E-mail: jakub.bielecki@ifj.edu.edu; Wójcik-Gargula, A.; Scholz, M.

    2016-11-15

    The article presents a new approach for investigation of spatial distributions of soft and hard X-rays emitted from dense magnetized plasma. The approach is based on the application of tomographic methods to the X-ray emission reconstruction in a plasma focus (PF) device. Quantitative investigation of the anisotropy of the reconstructed X–ray plasma emissivity may help to explain the nature of fusion reaction mechanisms in a PF device. The aim of this work is to present a conceptual design of a novel dual-energy X-ray emission tomographic system dedicated to the PF-24 plasma focus device. The system, which enables the simultaneous registration of soft and hard X-rays, is composed of three X‐ray pinhole cameras. Each camera is equipped with a pair of 16-element Si photodiode arrays arranged in two layers separated by an aluminum attenuator. The Geant4 code was used to optimize the layout and parameters of the applied detectors. In addition, a method of tomographic reconstruction from a sparse data set provided by the experimental setup has been presented.

  10. Tomographic PIV: principles and practice

    International Nuclear Information System (INIS)

    Scarano, F

    2013-01-01

    A survey is given of the major developments in three-dimensional velocity field measurements using the tomographic particle image velocimetry (PIV) technique. The appearance of tomo-PIV dates back seven years from the present review (Elsinga et al 2005a 6th Int. Symp. PIV (Pasadena, CA)) and this approach has rapidly spread as a versatile, robust and accurate technique to investigate three-dimensional flows (Arroyo and Hinsch 2008 Topics in Applied Physics vol 112 ed A Schröder and C E Willert (Berlin: Springer) pp 127–54) and turbulence physics in particular. A considerable number of applications have been achieved over a wide range of flow problems, which requires the current status and capabilities of tomographic PIV to be reviewed. The fundamental aspects of the technique are discussed beginning from hardware considerations for volume illumination, imaging systems, their configurations and system calibration. The data processing aspects are of uppermost importance: image pre-processing, 3D object reconstruction and particle motion analysis are presented with their fundamental aspects along with the most advanced approaches. Reconstruction and cross-correlation algorithms, attaining higher measurement precision, spatial resolution or higher computational efficiency, are also discussed. The exploitation of 3D and time-resolved (4D) tomographic PIV data includes the evaluation of flow field pressure on the basis of the flow governing equation. The discussion also covers a-posteriori error analysis techniques. The most relevant applications of tomo-PIV in fluid mechanics are surveyed, covering experiments in air and water flows. In measurements in flow regimes from low-speed to supersonic, most emphasis is given to the complex 3D organization of turbulent coherent structures. (topical review)

  11. Clamshell tomograph

    International Nuclear Information System (INIS)

    Derenzo, S. E.; Budinger, Th. F.

    1984-01-01

    In brief, the invention is a tomograph modified to be in a clamshell configuration so that the ring or rings may be moved to multiple sampling positions. The tomograph includes an array of detectors arranged in successive adjacent relative locations along a closed curve in a first position in a selected plane, and means for securing the detectors in the relative locations in a first sampling position. The securing means is movable in the plane in two sections and pivotable at one point and only one point to enable movement of at least one of the sections to a second sampling position out of the closed curve so that the ends of the section which are opposite the point are moved apart a predetermined space

  12. Multi-reception strategy with improved SNR for multichannel MR imaging.

    Directory of Open Access Journals (Sweden)

    Bing Wu

    Full Text Available A multi-reception strategy with extended GRAPPA is proposed in this work to improve MR imaging performance at ultra-high field MR systems with limited receiver channels. In this method, coil elements are separated to two or more groups under appropriate grouping criteria. Those groups are enabled in sequence for imaging first, and then parallel acquisition is performed to compensate for the redundant scan time caused by the multiple receptions. To efficiently reconstruct the data acquired from elements of each group, a specific extended GRAPPA was developed. This approach was evaluated by using a 16-element head array on a 7 Tesla whole-body MRI scanner with 8 receive channels. The in-vivo experiments demonstrate that with the same scan time, the 16-element array with twice receptions and acceleration rate of 2 can achieve significant SNR gain in the periphery area of the brain and keep nearly the same SNR in the center area over an eight-element array, which indicates the proposed multi-reception strategy and extended GRAPPA are feasible to improve image quality for MRI systems with limited receive channels. This study also suggests that it is advantageous for a MR system with N receiver channels to utilize a coil array with more than N elements if an appropriate acquisition strategy is applied.

  13. Development of a portable computed tomographic scanner for on-line imaging of industrial piping systems

    International Nuclear Information System (INIS)

    Jaafar Abdullah; Mohd Arif Hamzah; Mohd Soyapi Mohd Yusof; Mohd Fitri Abdul Rahman; Fadil IsmaiI; Rasif Mohd Zain

    2003-01-01

    Computed tomography (CT) technology is being increasingly developed for industrial application. This paper presents the development of a portable computed tomographic scanner for on?line imaging of industrial piping systems. The theoretical approach, the system hardware, the data acquisition system and the adopted algorithm for image reconstruction are discussed. The scanner has large potential to be used to determine the extent of corrosion under insulation (CUI), to detect blockages, to measure the thickness of deposit/materials built-up on the walls and to improve understanding of material flow in pipelines. (Author)

  14. Image interface in Java for tomographic reconstruction in nuclear medicine

    International Nuclear Information System (INIS)

    Andrade, M.A.; Silva, A.M. Marques da

    2004-01-01

    The aim of this study is to implement a software for tomographic reconstruction of SPECT data from Nuclear Medicine with a flexible interface design, cross-platform, written in Java. Validation tests were performed based on SPECT simulated data. The results showed that the implemented algorithms and filters agree with the theoretical context. We intend to extend the system by implementing additional tomographic reconstruction techniques and Java threads, in order to provide simultaneously image processing. (author)

  15. Achievement report for fiscal 1998. Optical tomographic system; 1998 nendo seika hokokusho. Hikari danso imaging system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    Evaluations were given on spatial resolution and measurement time of an optical tomographic system by using the developed 64-channel time-resolved spectroscopy and an image reconstruction algorithm. With respect to the spatial resolution, the target value of 1 cm was verified from tomographic images of a phantom with a diameter of 10cm, simulating a neonate. The measurement time achieved 20 minutes, being one third of the target value. In installing the equipment at Hokkaido University, speeds of the optical switches and attenuators were increased to have reduced the measurement time to one minute. For installation at Kanagawa Rehabilitation Center, development has been made on a nano-second light pulser, whose average beam quantity has been increased to 40 times, and improvement has been given on the optical switches, the attenuators, and the indication software, by which the measurement time was decreased further by 30 seconds than that at Hokkaido University. In performing the clinical evaluation, the evaluation protocol resolved by the Experiment Evaluation Special Committee was submitted for deliberation at the Medical Welfare Device Clinical Evaluation Committee. Upon having been authorized by the Committee, the clinical evaluations were performed at Hokkaido University and the Kanagawa Rehabilitation Center. (NEDO)

  16. High-throughput full-automatic synchrotron-based tomographic microscopy

    International Nuclear Information System (INIS)

    Mader, Kevin; Marone, Federica; Hintermueller, Christoph; Mikuljan, Gordan; Isenegger, Andreas; Stampanoni, Marco

    2011-01-01

    At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline of the Swiss Light Source with an energy range of 8-45 keV and voxel size from 0.37 (micro)m to 7.4 (micro)m, full tomographic datasets are typically acquired in 5 to 10 min. To exploit the speed of the system and enable high-throughput studies to be performed in a fully automatic manner, a package of automation tools has been developed. The samples are automatically exchanged, aligned, moved to the correct region of interest, and scanned. This task is accomplished through the coordination of Python scripts, a robot-based sample-exchange system, sample positioning motors and a CCD camera. The tools are suited for any samples that can be mounted on a standard SEM stub, and require no specific environmental conditions. Up to 60 samples can be analyzed at a time without user intervention. The throughput of the system is dependent on resolution, energy and sample size, but rates of four samples per hour have been achieved with 0.74 (micro)m voxel size at 17.5 keV. The maximum intervention-free scanning time is theoretically unlimited, and in practice experiments have been running unattended as long as 53 h (the average beam time allocation at TOMCAT is 48 h per user). The system is the first fully automated high-throughput tomography station: mounting samples, finding regions of interest, scanning and reconstructing can be performed without user intervention. The system also includes many features which accelerate and simplify the process of tomographic microscopy.

  17. SXR measurement and W transport survey using GEM tomographic system on WEST

    Science.gov (United States)

    Mazon, D.; Jardin, A.; Malard, P.; Chernyshova, M.; Coston, C.; Malard, P.; O'Mullane, M.; Czarski, T.; Malinowski, K.; Faisse, F.; Ferlay, F.; Verger, J. M.; Bec, A.; Larroque, S.; Kasprowicz, G.; Wojenski, A.; Pozniak, K.

    2017-11-01

    Measuring Soft X-Ray (SXR) radiation (0.1-20 keV) of fusion plasmas is a standard way of accessing valuable information on particle transport. Since heavy impurities like tungsten (W) could degrade plasma core performances and cause radiative collapses, it is necessary to develop new diagnostics to be able to monitor the impurity distribution in harsh fusion environments like ITER. A gaseous detector with energy discrimination would be a very good candidate for this purpose. The design and implementation of a new SXR diagnostic developed for the WEST project, based on a triple Gas Electron Multiplier (GEM) detector is presented. This detector works in photon counting mode and presents energy discrimination capabilities. The SXR system is composed of two 1D cameras (vertical and horizontal views respectively), located in the same poloidal cross-section to allow for tomographic reconstruction. An array (20 cm × 2 cm) consists of up to 128 detectors in front of a beryllium pinhole (equipped with a 1 mm diameter diaphragm) inserted at about 50 cm depth inside a cooled thimble in order to retrieve a wide plasma view. Acquisition of low energy spectrum is insured by a helium buffer installed between the pinhole and the detector. Complementary cooling systems (water) are used to maintain a constant temperature (25oC) inside the thimble. Finally a real-time automatic extraction system has been developed to protect the diagnostic during baking phases or any overheating unwanted events. Preliminary simulations of plasma emissivity and W distribution have been performed for WEST using a recently developed synthetic diagnostic coupled to a tomographic algorithm based on the minimum Fisher information (MFI) inversion method. First GEM acquisitions are presented as well as estimation of transport effect in presence of ICRH on W density reconstruction capabilities of the GEM.

  18. Resting-state functional connectivity assessed with two diffuse optical tomographic systems.

    Science.gov (United States)

    Niu, Haijing; Khadka, Sabin; Tian, Fenghua; Lin, Zi-Jing; Lu, Chunming; Zhu, Chaozhe; Liu, Hanli

    2011-04-01

    Functional near-infrared spectroscopy (fNIRS) is recently utilized as a new approach to assess resting-state functional connectivity (RSFC) in the human brain. For any new technique or new methodology, it is necessary to be able to replicate similar experiments using different instruments in order to establish its liability and reproducibility. We apply two different diffuse optical tomographic (DOT) systems (i.e., DYNOT and CW5), with various probe arrangements to evaluate RSFC in the sensorimotor cortex by utilizing a previously published experimental protocol and seed-based correlation analysis. Our results exhibit similar spatial patterns and strengths in RSFC between the bilateral motor cortexes. The consistent observations are obtained from both DYNOT and CW5 systems, and are also in good agreement with the previous fNIRS study. Overall, we demonstrate that the fNIRS-based RSFC is reproducible by various DOT imaging systems among different research groups, enhancing the confidence of neuroscience researchers and clinicians to utilize fNIRS for future applications.

  19. Adult smokers' receptivity to a television advert for electronic nicotine delivery systems.

    Science.gov (United States)

    Kim, Annice E; Lee, Youn Ok; Shafer, Paul; Nonnemaker, James; Makarenko, Olga

    2015-03-01

    The aim of the present work was to examine adult smokers' awareness of and receptivity to an electronic nicotine delivery system (ENDS) television advert, and whether viewing the advert influenced urge to smoke and intention to try ENDS. A television advert for ENDS brand blu eCigs was shown to an online convenience sample of 519 Florida adult smokers. We measured current smokers' awareness of and receptivity to the advert, and whether seeing the advert influenced their thoughts about smoking or quitting, urge to smoke and intention to try ENDS. Results were stratified by prior ENDS use. Approximately 62.3% of current smokers were aware of the advert. Smokers found the advert informative (73.8%), attention grabbing (67.5%) and innovative (64.5%), with prior ENDS users rating the advert more favourably than non-users. Seeing the advert elicited an urge to smoke (mean 42.1, SD=1.9) and thoughts about smoking cigarettes (75.8%) as well as quitting (74.6%). Prior END users were significantly more likely than non-users to report thinking about smoking cigarettes after seeing the advert (Padvertising and examine how exposure to ENDS adverts influences smokers' use of ENDS, dual use with cigarettes and cessation behaviour. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. X-ray tomographic apparatus

    International Nuclear Information System (INIS)

    Walters, R.G.

    1982-01-01

    An x-ray tomographic system consists of a radiation source such as gamma or x radiation which produces a fan-shaped beam. The fan is wide enough to encompass the patient circle. The system further includes means for rotating the radiation source about the patient for less than a full rotation, and detectors for detecting the radiation at positions that surround the patient by 180 0 plus the angle of the fan beam plus the angle between adjacent fan detectors. Attenuation data from the detectors is sorted into detector fans of attenuation data, then processed. The convolved data is back-projected into an image memory and displayed on a video monitor

  1. Surface-Borne Time-of-Reception Measurements (STORM), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Invocon proposes the Surface-borne Time-Of-Reception Measurements (STORM) system as a method to locate the position of lightning strikes on aerospace vehicles....

  2. Gravitational wave reception by a sphere

    International Nuclear Information System (INIS)

    Ashby, N.; Dreitlein, J.

    1975-01-01

    The reception of gravitational waves by an elastic self-gravitating spherical detector is studied in detail. The equations of motion of a detector driven by a gravitational wave are presented in the intuitively convenient coordinate system of Fermi. An exact analytic solution is given for the homogeneous isotropic sphere. Nonlinear effects of a massive self-gravitating system are computed for a body of mass equal to that of the earth, and are shown to be numerically important

  3. TEACHING COMMUNICATIVE TRANSLATION: AN ACTIVE RECEPTION ANALYSIS BETWEEN THE TRANSLATION AND READER’S RECEPTION

    Directory of Open Access Journals (Sweden)

    Venny Eka Meidasari

    2014-06-01

    Full Text Available Literary theory sees reception theory from the reader response that emphasizes the reader’s reception of a literary text. It is generally called audience reception in the analysis of communications models. In literary studies, reception theory originated from the work of Hans-Robert Jauss in the late 1960s. Communication only means that the original message will be clearly sent in its equivalent context to the target receptor. Similarly, the main role of translators is to send the message across without any form of distortion or emphasis. It is delivering the genuine context of the message to the language that the active receptor understands. A single mistake in a context translation can result to offensive message that can eventually lead to misunderstandings between active receptors. This paper proposes on the role of translator as the mediator between a writer of the original text and the active target language receptors of translated version in the course of communication which definitely affects the process and result of translation practice. It also reveals the emphasis on the creation text of the translation theories originated from the strategic communication theories, which hopefully leads to a dream of the most equivalence between the text and the translated version.

  4. Design and construction of the gamma ray transmission tomographer g-TAC-02

    International Nuclear Information System (INIS)

    Pavon Hernandez, Noriel; Ravelo Sanchez, Alberto; Idel, Pedro; Macias Perez, Rafael; Garcia Trapaga, Cesar; Campos Montenegro, Augusto

    2000-01-01

    An equipment for gamma ray transmission tomographer was designed and constructed in the Higher Institute of Nuclear Sciences and Technology. It was the g-TAC-01, based on a nuclear instrumentation, a mechanic instrumentation, and the control of the system from a personal computer. This first version permitted to obtain the know how of the technology of construction of equipment for tomography. The present work describes the second version of the gamma ray transmission tomographer: the g-TAC-02, with very important upgrading in the control session. Now the control system is a microcontroller based, electronic control system, designed to work in multiples forms: manual, automatic and with the computer

  5. A detailed comparison of single-camera light-field PIV and tomographic PIV

    Science.gov (United States)

    Shi, Shengxian; Ding, Junfei; Atkinson, Callum; Soria, Julio; New, T. H.

    2018-03-01

    This paper conducts a comprehensive study between the single-camera light-field particle image velocimetry (LF-PIV) and the multi-camera tomographic particle image velocimetry (Tomo-PIV). Simulation studies were first performed using synthetic light-field and tomographic particle images, which extensively examine the difference between these two techniques by varying key parameters such as pixel to microlens ratio (PMR), light-field camera Tomo-camera pixel ratio (LTPR), particle seeding density and tomographic camera number. Simulation results indicate that the single LF-PIV can achieve accuracy consistent with that of multi-camera Tomo-PIV, but requires the use of overall greater number of pixels. Experimental studies were then conducted by simultaneously measuring low-speed jet flow with single-camera LF-PIV and four-camera Tomo-PIV systems. Experiments confirm that given a sufficiently high pixel resolution, a single-camera LF-PIV system can indeed deliver volumetric velocity field measurements for an equivalent field of view with a spatial resolution commensurate with those of multi-camera Tomo-PIV system, enabling accurate 3D measurements in applications where optical access is limited.

  6. Linear analysis of rotationally invariant, radially variant tomographic imaging systems

    International Nuclear Information System (INIS)

    Huesmann, R.H.

    1990-01-01

    This paper describes a method to analyze the linear imaging characteristics of rotationally invariant, radially variant tomographic imaging systems using singular value decomposition (SVD). When the projection measurements from such a system are assumed to be samples from independent and identically distributed multi-normal random variables, the best estimate of the emission intensity is given by the unweighted least squares estimator. The noise amplification of this estimator is inversely proportional to the singular values of the normal matrix used to model projection and backprojection. After choosing an acceptable noise amplification, the new method can determine the number of parameters and hence the number of pixels that should be estimated from data acquired from an existing system with a fixed number of angles and projection bins. Conversely, for the design of a new system, the number of angles and projection bins necessary for a given number of pixels and noise amplification can be determined. In general, computing the SVD of the projection normal matrix has cubic computational complexity. However, the projection normal matrix for this class of rotationally invariant, radially variant systems has a block circulant form. A fast parallel algorithm to compute the SVD of this block circulant matrix makes the singular value analysis practical by asymptotically reducing the computation complexity of the method by a multiplicative factor equal to the number of angles squared

  7. A high-throughput system for high-quality tomographic reconstruction of large datasets at Diamond Light Source.

    Science.gov (United States)

    Atwood, Robert C; Bodey, Andrew J; Price, Stephen W T; Basham, Mark; Drakopoulos, Michael

    2015-06-13

    Tomographic datasets collected at synchrotrons are becoming very large and complex, and, therefore, need to be managed efficiently. Raw images may have high pixel counts, and each pixel can be multidimensional and associated with additional data such as those derived from spectroscopy. In time-resolved studies, hundreds of tomographic datasets can be collected in sequence, yielding terabytes of data. Users of tomographic beamlines are drawn from various scientific disciplines, and many are keen to use tomographic reconstruction software that does not require a deep understanding of reconstruction principles. We have developed Savu, a reconstruction pipeline that enables users to rapidly reconstruct data to consistently create high-quality results. Savu is designed to work in an 'orthogonal' fashion, meaning that data can be converted between projection and sinogram space throughout the processing workflow as required. The Savu pipeline is modular and allows processing strategies to be optimized for users' purposes. In addition to the reconstruction algorithms themselves, it can include modules for identification of experimental problems, artefact correction, general image processing and data quality assessment. Savu is open source, open licensed and 'facility-independent': it can run on standard cluster infrastructure at any institution.

  8. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are presented of a tomographic scanning apparatus, its rotational assembly, and the control and circuit elements, with particular reference to the amplifier and multiplexing circuits enabling detector signal calibration. (U.K.)

  9. Note from the Goods Reception services

    CERN Multimedia

    FI Department

    2008-01-01

    Members of the personnel are invited to take note that only parcels corresponding to official orders or contracts will be handled at CERN. Individuals are not authorised to have private merchandise delivered to them at CERN and private deliveries will not be accepted by the Goods Reception services. Goods Reception Services

  10. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to a multiplexer slip ring means for receiving output from the detectors and enabling interfeed to the image reconstruction station. (U.K.)

  11. Computer tomographic diagnosis of echinococcosis

    Energy Technology Data Exchange (ETDEWEB)

    Haertel, M.; Fretz, C.; Fuchs, W.A.

    1980-08-01

    The computer tomographic appearances and differential diagnosis in 22 patients with echinococcosis are described; of these, twelve were of the cystic and ten of the alveolar type. The computer tomographic appearances are characterised by the presence of daughter cysts (66%) within the sharply demarkated parasitic cyst of water density. In the absence of daughter cysts, a definite aetiological diagnosis cannot be made, although there is a tendency to clasification of the occassionally multiple echinococcus cysts. The computer tomographic appearances of advanced alveolar echinococcosis are characterised by partial collequative necrosis, with clacification around the necrotic areas (90%). The absence of CT evidence of partial necrosis and calsification of the pseudotumour makes it difficult to establish a specific diagnosis. The conclusive and non-invasive character of the procedure and its reproducibility makes computer tomography the method of choice for the diagnosis and follow-up of echinococcosis.

  12. Rehabilitering og 'motion på recept'

    DEFF Research Database (Denmark)

    Larsen, Niels Sandholm; Larsen, Kristian

    2008-01-01

    af disse forskningsarbejder er etablering af fænomenet 'motion på recept'. Konceptet om 'motion på recept' stammer oprindelig fra Sverige, hvor praktiserende læger i en periode har haft mulighed for at henvise visse typer af patienter til fysisk træning hos praktiserende fysioterapeuter. Ribe Amt...... 2007)....

  13. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-file Systems.

    Science.gov (United States)

    Prabhakar, Attiguppe R; Yavagal, Chandrashekar; Dixit, Kratika; Naik, Saraswathi V

    2016-01-01

    Primary root canals are considered to be most challenging due to their complex anatomy. "Wave one" and "one shape" are single-file systems with reciprocating and rotary motion respectively. The aim of this study was to evaluate and compare dentin thickness, centering ability, canal transportation, and instrumentation time of wave one and one shape files in primary root canals using a cone beam computed tomographic (CBCT) analysis. This is an experimental, in vitro study comparing the two groups. A total of 24 extracted human primary teeth with minimum 7 mm root length were included in the study. Cone beam computed tomographic images were taken before and after the instrumentation for each group. Dentin thickness, centering ability, canal transportation, and instrumentation times were evaluated for each group. A significant difference was found in instrumentation time and canal transportation measures between the two groups. Wave one showed less canal transportation as compared with one shape, and the mean instrumentation time of wave one was significantly less than one shape. Reciprocating single-file systems was found to be faster with much less procedural errors and can hence be recommended for shaping the root canals of primary teeth. How to cite this article: Prabhakar AR, Yavagal C, Dixit K, Naik SV. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-File Systems. Int J Clin Pediatr Dent 2016;9(1):45-49.

  14. Language, gay pornography, and audience reception.

    Science.gov (United States)

    Leap, William L

    2011-01-01

    Erotic imagery is an important component of gay pornographic cinema, particularly, where work of audience reception is concerned. However, to assume the audience engagement with the films is limited solely to the erotic realm is to underestimate the workings of ideological power in the context and aftermath of reception. For example, the director of the film under discussion here (Men of Israel; Lucas, 2009b) intended to present an erotic celebration of the nation-state. Yet, most viewers ignore the particulars of context in their comments about audience reception, placing the "Israeli" narrative within a broader framework, using transnational rather than film-specific criteria to guide their "reading" of the Israeli-centered narrative. This article uses as its entry point the language that viewers employ when describing their reactions to Men of Israel on a gay video club's Web site; this article shows how the work of audience reception may draw attention to a film's erotic details while invoking social and political messages that completely reframe the film's erotic narrative.

  15. Determination of spatial resolution of positron emission tomograph of clear PET-XPAD3/CT system

    Energy Technology Data Exchange (ETDEWEB)

    Olaya D, H.; Martinez O, S. A. [Universidad Pedagogica y Tecnologica de Colombia, Grupo de Fisica Nuclear Aplicada y Simulacion, 150003 Tunja, Boyaca (Colombia); Morel, C. [Centre de Physique des Particules de Marseille, ImXgam Group, 13009 Marseille (France); Castro, H. F. [Universidad Nacional de Colombia, Physics Department, Carrera 45 No. 26-85, Bogota (Colombia)

    2016-10-15

    Based on the National Electrical Manufacturers Association (Nema), using the Amine software to construction of sinograms and using a radioactive source {sup 22}Na that emitting positrons were made calculations for determine spatial resolution of ring array system of phoswich detectors of positron emission tomograph included in the Clear PET-XPAD3/CT prototype for small animals made in the laboratories of CCPM and whose project is led by the research group ImXgam. The radioactive source {sup 22}Na approximately 9 MBq of activity, with spherical shape and diameter of 0.57 mm immersed in a plexiglas disc was located at the geometric center of tomographic system with a Field of View (Fov) of 35 mm in the axial and transverse directions. Displacements of radioactive source were performed on the three cartesian axes and was rebuilt a sinogram for each axis. The shape of sinogram allow describe the correct position and the maximum efficiency of each detector. Subsequently, was carried out a scanning in each one of three spatial axes taking an enough distance covering the dimensions of radioactive source, were recorded data for each one of phoswich detector crystals which are aligned in the axis of movement. The process was repeated for other axes and then was offsetting the radioactive source with respect to the Fov and were calculated FWHM (Full Width at Half Maximum) and FWTM (Full Width at Tenth Maximum) values and performing statistics of these values with parabolic fitting, the latter setting allows to obtain parameters of spatial resolution of system. (Author)

  16. Determination of spatial resolution of positron emission tomograph of clear PET-XPAD3/CT system

    International Nuclear Information System (INIS)

    Olaya D, H.; Martinez O, S. A.; Morel, C.; Castro, H. F.

    2016-10-01

    Based on the National Electrical Manufacturers Association (Nema), using the Amine software to construction of sinograms and using a radioactive source "2"2Na that emitting positrons were made calculations for determine spatial resolution of ring array system of phoswich detectors of positron emission tomograph included in the Clear PET-XPAD3/CT prototype for small animals made in the laboratories of CCPM and whose project is led by the research group ImXgam. The radioactive source "2"2Na approximately 9 MBq of activity, with spherical shape and diameter of 0.57 mm immersed in a plexiglas disc was located at the geometric center of tomographic system with a Field of View (Fov) of 35 mm in the axial and transverse directions. Displacements of radioactive source were performed on the three cartesian axes and was rebuilt a sinogram for each axis. The shape of sinogram allow describe the correct position and the maximum efficiency of each detector. Subsequently, was carried out a scanning in each one of three spatial axes taking an enough distance covering the dimensions of radioactive source, were recorded data for each one of phoswich detector crystals which are aligned in the axis of movement. The process was repeated for other axes and then was offsetting the radioactive source with respect to the Fov and were calculated FWHM (Full Width at Half Maximum) and FWTM (Full Width at Tenth Maximum) values and performing statistics of these values with parabolic fitting, the latter setting allows to obtain parameters of spatial resolution of system. (Author)

  17. Unaccompanied adolescents seeking asylum - Poorer mental health under a restrictive reception : poorer mental health under a restrictive reception

    NARCIS (Netherlands)

    Reijneveld, S.A.; de Boer, J.B.; Bean, T.; Korfker, D.G.

    2005-01-01

    We assessed the effects of a stringent reception policy on the mental health of unaccompanied adolescent asylum seekers by comparing the mental health of adolescents in a restricted campus reception setting and in a setting offering more autonomy (numbers [response rates]: 69 [93%] and 53 [69%],

  18. Tomographic visualization of stress corrosion cracks in tubing

    International Nuclear Information System (INIS)

    Morris, R.A.; Kruger, R.P.; Wecksung, G.W.

    1979-06-01

    A feasibility study was conducted to determine the possibility of detecting and sizing cracks in reactor cooling water tubes using tomographic techniques. Due to time and financial constraints, only one tomographic reconstruction using the best technique available was made. The results indicate that tomographic reconstructions can, in fact, detect cracks in the tubing and might possibly be capable of measuring the depth of the cracks. Limits of detectability and sensitivity have not been determined but should be investigated in any future work

  19. A digital-signal-processor-based optical tomographic system for dynamic imaging of joint diseases

    Science.gov (United States)

    Lasker, Joseph M.

    Over the last decade, optical tomography (OT) has emerged as viable biomedical imaging modality. Various imaging systems have been developed that are employed in preclinical as well as clinical studies, mostly targeting breast imaging, brain imaging, and cancer related studies. Of particular interest are so-called dynamic imaging studies where one attempts to image changes in optical properties and/or physiological parameters as they occur during a system perturbation. To successfully perform dynamic imaging studies, great effort is put towards system development that offers increasingly enhanced signal-to-noise performance at ever shorter data acquisition times, thus capturing high fidelity tomographic data within narrower time periods. Towards this goal, I have developed in this thesis a dynamic optical tomography system that is, unlike currently available analog instrumentation, based on digital data acquisition and filtering techniques. At the core of this instrument is a digital signal processor (DSP) that collects, collates, and processes the digitized data set. Complementary protocols between the DSP and a complex programmable logic device synchronizes the sampling process and organizes data flow. Instrument control is implemented through a comprehensive graphical user interface which integrates automated calibration, data acquisition, and signal post-processing. Real-time data is generated at frame rates as high as 140 Hz. An extensive dynamic range (˜190 dB) accommodates a wide scope of measurement geometries and tissue types. Performance analysis demonstrates very low system noise (˜1 pW rms noise equivalent power), excellent signal precision (˜0.04%--0.2%) and long term system stability (˜1% over 40 min). Experiments on tissue phantoms validate spatial and temporal accuracy of the system. As a potential new application of dynamic optical imaging I present the first application of this method to use vascular hemodynamics as a means of characterizing

  20. Tomographic method and apparatus

    International Nuclear Information System (INIS)

    Moore, R.M.

    1981-01-01

    A tomographic x-ray machine has a camera and film-plane section which move about a primary axis for imaging a selected cross-section of an anatomical member onto the film. A ''scout image'' of the member is taken at right angles to the plane of the desired cross-section to indicate the cross-section's angle with respect to the primary axis. The film plane is then located at the same angle with respect to a film cassette axis as the selected cross-section makes with the primary axis. The film plane and the cross-section are then maintained in parallel planes throughout motion of the camera and film plane during tomographic radiography. (author)

  1. Diversity Networking Reception

    Science.gov (United States)

    2014-03-01

    Join us at the APS Diversity Reception to relax, network with colleagues, and learn about programs and initiatives for women, underrepresented minorities, and LGBT physicists. You'll have a great time meeting friends in a supportive environment and making connections.

  2. Industrial dynamic tomographic reconstruction; Reconstrucao tomografica dinamica industrial

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Eric Ferreira de

    2016-07-01

    The state of the art methods applied to industrial processes is currently based on the principles of classical tomographic reconstructions developed for tomographic patterns of static distributions, or is limited to cases of low variability of the density distribution function of the tomographed object. Noise and motion artifacts are the main problems caused by a mismatch in the data from views acquired in different instants. All of these add to the known fact that using a limited amount of data can result in the presence of noise, artifacts and some inconsistencies with the distribution under study. One of the objectives of the present work is to discuss the difficulties that arise from implementing reconstruction algorithms in dynamic tomography that were originally developed for static distributions. Another objective is to propose solutions that aim at reducing a temporal type of information loss caused by employing regular acquisition systems to dynamic processes. With respect to dynamic image reconstruction it was conducted a comparison between different static reconstruction methods, like MART and FBP, when used for dynamic scenarios. This comparison was based on a MCNPx simulation as well as an analytical setup of an aluminum cylinder that moves along the section of a riser during the process of acquisition, and also based on cross section images from CFD techniques. As for the adaptation of current tomographic acquisition systems for dynamic processes, this work established a sequence of tomographic views in a just-in-time fashion for visualization purposes, a form of visually disposing density information as soon as it becomes amenable to image reconstruction. A third contribution was to take advantage of the triple color channel necessary to display colored images in most displays, so that, by appropriately scaling the acquired values of each view in the linear system of the reconstruction, it was possible to imprint a temporal trace into the regularly

  3. Computed tomographic determination of tracheal dimensions in children and adolescents

    International Nuclear Information System (INIS)

    Griscom, N.T.

    1982-01-01

    A computed tomographic system for determining the internal diameters, cross-sectional area, and length of the trachea in children and adolescents was developed. Intraluminal volumes were calculated from these measurements.The results of 18 analyses are reported

  4. Spectrotemporal dynamics of auditory cortical synaptic receptive field plasticity.

    Science.gov (United States)

    Froemke, Robert C; Martins, Ana Raquel O

    2011-09-01

    The nervous system must dynamically represent sensory information in order for animals to perceive and operate within a complex, changing environment. Receptive field plasticity in the auditory cortex allows cortical networks to organize around salient features of the sensory environment during postnatal development, and then subsequently refine these representations depending on behavioral context later in life. Here we review the major features of auditory cortical receptive field plasticity in young and adult animals, focusing on modifications to frequency tuning of synaptic inputs. Alteration in the patterns of acoustic input, including sensory deprivation and tonal exposure, leads to rapid adjustments of excitatory and inhibitory strengths that collectively determine the suprathreshold tuning curves of cortical neurons. Long-term cortical plasticity also requires co-activation of subcortical neuromodulatory control nuclei such as the cholinergic nucleus basalis, particularly in adults. Regardless of developmental stage, regulation of inhibition seems to be a general mechanism by which changes in sensory experience and neuromodulatory state can remodel cortical receptive fields. We discuss recent findings suggesting that the microdynamics of synaptic receptive field plasticity unfold as a multi-phase set of distinct phenomena, initiated by disrupting the balance between excitation and inhibition, and eventually leading to wide-scale changes to many synapses throughout the cortex. These changes are coordinated to enhance the representations of newly-significant stimuli, possibly for improved signal processing and language learning in humans. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. 3D velocity measurements in a premixed flame by tomographic PIV

    International Nuclear Information System (INIS)

    Tokarev, M P; Sharaborin, D K; Lobasov, A S; Chikishev, L M; Dulin, V M; Markovich, D M

    2015-01-01

    Tomographic particle image velocimetry (PIV) has become a standard tool for 3D velocity measurements in non-reacting flows. However, the majority of the measurements in flows with combustion are limited to small resolved depth compared to the size of the field of view (typically 1 : 10). The limitations are associated with inhomogeneity of the volume illumination and the non-uniform flow seeding, the optical distortions and errors in the 3D calibration, and the unwanted flame luminosity. In the present work, the above constraints were overcome for the tomographic PIV experiment in a laminar axisymmetric premixed flame. The measurements were conducted for a 1 : 1 depth-to-size ratio using a system of eight CCD cameras and a 200 mJ pulsed laser. The results show that camera calibration based on the triangulation of the tracer particles in the non-reacting conditions provided reliable accuracy for the 3D image reconstruction in the flame. The modification of the tomographic reconstruction allowed a posteriori removal of unwanted bright objects, which were located outside of the region of interest but affected the reconstruction quality. This study reports on a novel experience for the instantaneous 3D velocimetry in laboratory-scale flames by using tomographic PIV. (paper)

  6. DS-CDMA satellite diversity reception for personal satellite communication: Downlink performance analysis

    Science.gov (United States)

    DeGaudenzi, Riccardo; Giannetti, Filippo

    1995-01-01

    The downlink of a satellite-mobile personal communication system employing power-controlled Direct Sequence Code Division Multiple Access (DS-CDMA) and exploiting satellite-diversity is analyzed and its performance compared with a more traditional communication system utilizing single satellite reception. The analytical model developed has been thoroughly validated by means of extensive Monte Carlo computer simulations. It is shown how the capacity gain provided by diversity reception shrinks considerably in the presence of increasing traffic or in the case of light shadowing conditions. Moreover, the quantitative results tend to indicate that to combat system capacity reduction due to intra-system interference, no more than two satellites shall be active over the same region. To achieve higher system capacity, differently from terrestrial cellular systems, Multi-User Detection (MUD) techniques are likely to be required in the mobile user terminal, thus considerably increasing its complexity.

  7. Receptivity to Tobacco Advertising and Susceptibility to Tobacco Products.

    Science.gov (United States)

    Pierce, John P; Sargent, James D; White, Martha M; Borek, Nicolette; Portnoy, David B; Green, Victoria R; Kaufman, Annette R; Stanton, Cassandra A; Bansal-Travers, Maansi; Strong, David R; Pearson, Jennifer L; Coleman, Blair N; Leas, Eric; Noble, Madison L; Trinidad, Dennis R; Moran, Meghan B; Carusi, Charles; Hyland, Andrew; Messer, Karen

    2017-06-01

    Non-cigarette tobacco marketing is less regulated and may promote cigarette smoking among adolescents. We quantified receptivity to advertising for multiple tobacco products and hypothesized associations with susceptibility to cigarette smoking. Wave 1 of the nationally representative PATH (Population Assessment of Tobacco and Health) study interviewed 10 751 adolescents who had never used tobacco. A stratified random selection of 5 advertisements for each of cigarettes, e-cigarettes, smokeless products, and cigars were shown from 959 recent tobacco advertisements. Aided recall was classified as low receptivity, and image-liking or favorite ad as higher receptivity. The main dependent variable was susceptibility to cigarette smoking. Among US youth, 41% of 12 to 13 year olds and half of older adolescents were receptive to at least 1 tobacco advertisement. Across each age group, receptivity to advertising was highest for e-cigarettes (28%-33%) followed by cigarettes (22%-25%), smokeless tobacco (15%-21%), and cigars (8%-13%). E-cigarette ads shown on television had the highest recall. Among cigarette-susceptible adolescents, receptivity to e-cigarette advertising (39.7%; 95% confidence interval [CI]: 37.9%-41.6%) was higher than for cigarette advertising (31.7%; 95% CI: 29.9%-33.6%). Receptivity to advertising for each tobacco product was associated with increased susceptibility to cigarette smoking, with no significant difference across products (similar odds for both cigarette and e-cigarette advertising; adjusted odds ratio = 1.22; 95% CI: 1.09-1.37). A large proportion of US adolescent never tobacco users are receptive to tobacco advertising, with television advertising for e-cigarettes having the highest recall. Receptivity to advertising for each non-cigarette tobacco product was associated with susceptibility to smoke cigarettes. Copyright © 2017 by the American Academy of Pediatrics.

  8. Characterization of tomographically faithful states in terms of their Wigner function

    International Nuclear Information System (INIS)

    D'Ariano, G M; Sacchi, M F

    2005-01-01

    A bipartite quantum state is tomographically faithful when it can be used as an input of a quantum operation acting on one of the two quantum systems, such that the joint output state carries complete information about the operation itself. Tomographically faithful states are a necessary ingredient for the tomography of quantum operations and for complete quantum calibration of measuring apparatuses. In this paper we provide a complete classification of such states for continuous variables in terms of the Wigner function of the state. For two-mode Gaussian states faithfulness simply resorts to correlation between the modes

  9. Unfolding and smoothing applied to the quality enhancement of neutron tomographic images

    International Nuclear Information System (INIS)

    Almeida, Gevaldo L. de; Silvani, Maria I.; Lopes, Ricardo T.

    2008-01-01

    Resolution and contrast are the major parameters defining the quality of a computer-aided tomographic image. These parameters depend upon several features of the image acquisition system, such as detector resolution, geometrical arrangement of the source-object-detector, beam divergence, source strength, detector efficiency and counting time. Roughly, the detector finite resolution is the main source of systematic errors affecting the separation power of the image acquisition system, while the electronic noise and statistical fluctuation are responsible for the data dispersion, which spoils the contrast. An algorithm has been developed in this work aiming at the improvement of the image quality through the minimization of both types of errors. The systematic ones are reduced by a mathematical unfolding of the position spectra - used as projections to reconstruct the 2D-images - using the Line Spread Function - LSF of the neutron tomographic system. The principle behind this technique is that every single channel contains information about all channels of the spectrum, but it is concealed due to the automatic integration carried out by the detector. Therefore, knowing the shape of this curve, it is possible to retrieve the original spectra. These spectra are unfortunately corrupted by the unavoidable statistical fluctuation, and by oscillations arising from the unfolding process, which strongly affects the quality of the final unfolded image. In order to reduce this impact, the spectra have been filtered by a Fourier transform technique or smoothed with a least square fitting procedure. The algorithm has been applied to spectra of some test-bodies generated by an earlier developed tomographic simulator, which reproduces the spectra furnished by a thermal neutron tomographic system employing a position sensitive detector. The obtained results have shown that the unfolded spectra produce final images capable to resolve features otherwise not achievable with the

  10. Precision of quantum tomographic detection of radiation

    Energy Technology Data Exchange (ETDEWEB)

    D' Ariano, G.M. (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy) Istituto Nazionale di Fisica Nucleare, Sezione di Pavia, Via A. Bassi 6, I-27100, Pavia (Italy)); Macchiavello, Chiara (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy)); Paris, M.G.A. (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy))

    1994-11-21

    Homodyne tomography provides an experimental technique for reconstructing the density matrix of the radiation field. Here we analyze the tomographic precision in recovering observables like the photon number, the quadrature, and the phase. We show that tomographic reconstruction, despite providing a complete characterization of the state of the field, is generally much less efficient than conventional detection techniques. ((orig.))

  11. Precision of quantum tomographic detection of radiation

    International Nuclear Information System (INIS)

    D'Ariano, G.M.; Macchiavello, Chiara; Paris, M.G.A.

    1994-01-01

    Homodyne tomography provides an experimental technique for reconstructing the density matrix of the radiation field. Here we analyze the tomographic precision in recovering observables like the photon number, the quadrature, and the phase. We show that tomographic reconstruction, despite providing a complete characterization of the state of the field, is generally much less efficient than conventional detection techniques. ((orig.))

  12. Natural image sequences constrain dynamic receptive fields and imply a sparse code.

    Science.gov (United States)

    Häusler, Chris; Susemihl, Alex; Nawrot, Martin P

    2013-11-06

    In their natural environment, animals experience a complex and dynamic visual scenery. Under such natural stimulus conditions, neurons in the visual cortex employ a spatially and temporally sparse code. For the input scenario of natural still images, previous work demonstrated that unsupervised feature learning combined with the constraint of sparse coding can predict physiologically measured receptive fields of simple cells in the primary visual cortex. This convincingly indicated that the mammalian visual system is adapted to the natural spatial input statistics. Here, we extend this approach to the time domain in order to predict dynamic receptive fields that can account for both spatial and temporal sparse activation in biological neurons. We rely on temporal restricted Boltzmann machines and suggest a novel temporal autoencoding training procedure. When tested on a dynamic multi-variate benchmark dataset this method outperformed existing models of this class. Learning features on a large dataset of natural movies allowed us to model spatio-temporal receptive fields for single neurons. They resemble temporally smooth transformations of previously obtained static receptive fields and are thus consistent with existing theories. A neuronal spike response model demonstrates how the dynamic receptive field facilitates temporal and population sparseness. We discuss the potential mechanisms and benefits of a spatially and temporally sparse representation of natural visual input. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.

  13. Development of a laser-based heating system for in situ synchrotron-based X-ray tomographic microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Fife, Julie L., E-mail: julie.fife@psi.ch [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); Computational Materials Laboratory, Ecole Polytechnique Federale de Lausanne, Lausanne (Switzerland); Rappaz, Michel [Computational Materials Laboratory, Ecole Polytechnique Federale de Lausanne, Lausanne (Switzerland); Pistone, Mattia [Institute for Geochemistry and Petrology, Swiss Federal Institute of Technology of Zurich, Zurich (Switzerland); Celcer, Tine [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); The Centre of Excellence for Biosensors, Instrumentation and Process Control, Solkan (Slovenia); Mikuljan, Gordan [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); Stampanoni, Marco [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); Institute for Biomedical Engineering, Swiss Federal Institute of Technology and University of Zurich, Zurich (Switzerland)

    2012-05-01

    A laser-based heating system has been developed at the TOMCAT beamline of the Swiss Light Source for in situ observations of moderate-to-high-temperature applications of materials. Understanding the formation of materials at elevated temperatures is critical for determining their final properties. Synchrotron-based X-ray tomographic microscopy is an ideal technique for studying such processes because high spatial and temporal resolutions are easily achieved and the technique is non-destructive, meaning additional analyses can take place after data collection. To exploit the state-of-the-art capabilities at the tomographic microscopy and coherent radiology experiments (TOMCAT) beamline of the Swiss Light Source, a general-use moderate-to-high-temperature furnace has been developed. Powered by two diode lasers, it provides controlled localized heating, from 673 to 1973 K, to examine many materials systems and their dynamics in real time. The system can also be operated in various thermal modalities. For example, near-isothermal conditions at a given sample location can be achieved with a prescribed time-dependent temperature. This mode is typically used to study isothermal phase transformations; for example, the formation of equiaxed grains in metallic systems or to nucleate and grow bubble foams in silicate melts under conditions that simulate volcanic processes. In another mode, the power of the laser can be fixed and the specimen moved at a constant speed in a user-defined thermal gradient. This is similar to Bridgman solidification, where the thermal gradient and cooling rate control the microstructure formation. This paper details the experimental set-up and provides multiple proofs-of-concept that illustrate the versatility of using this laser-based heating system to explore, in situ, many elevated-temperature phenomena in a variety of materials.

  14. Computer tomographs

    International Nuclear Information System (INIS)

    Niedzwiedzki, M.

    1982-01-01

    Physical foundations and the developments in the transmission and emission computer tomography are presented. On the basis of the available literature and private communications a comparison is made of the various transmission tomographs. A new technique of computer emission tomography ECT, unknown in Poland, is described. The evaluation of two methods of ECT, namely those of positron and single photon emission tomography is made. (author)

  15. Receptivity to alcohol marketing predicts initiation of alcohol use.

    Science.gov (United States)

    Henriksen, Lisa; Feighery, Ellen C; Schleicher, Nina C; Fortmann, Stephen P

    2008-01-01

    This longitudinal study examined the influence of alcohol advertising and promotions on the initiation of alcohol use. A measure of receptivity to alcohol marketing was developed from research about tobacco marketing. Recall and recognition of alcohol brand names were also examined. Data were obtained from in-class surveys of sixth, seventh, and eighth graders at baseline and 12-month follow-up. Participants who were classified as never drinkers at baseline (n = 1,080) comprised the analysis sample. Logistic regression models examined the association of advertising receptivity at baseline with any alcohol use and current drinking at follow-up, adjusting for multiple risk factors, including peer alcohol use, school performance, risk taking, and demographics. At baseline, 29% of never drinkers either owned or wanted to use an alcohol branded promotional item (high receptivity), 12% students named the brand of their favorite alcohol ad (moderate receptivity), and 59% were not receptive to alcohol marketing. Approximately 29% of adolescents reported any alcohol use at follow-up; 13% reported drinking at least 1 or 2 days in the past month. Never drinkers who reported high receptivity to alcohol marketing at baseline were 77% more likely to initiate drinking by follow-up than those were not receptive. Smaller increases in the odds of alcohol use at follow-up were associated with better recall and recognition of alcohol brand names at baseline. Alcohol advertising and promotions are associated with the uptake of drinking. Prevention programs may reduce adolescents' receptivity to alcohol marketing by limiting their exposure to alcohol ads and promotions and by increasing their skepticism about the sponsors' marketing tactics.

  16. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to the means of adjusting the apparent gain of the signal processing means for receiving output signals from the detectors, to compensate for drift in the gain characteristics, including means for passing a reference signal. (U.K.)

  17. A review of recommendations for sequencing receptive and expressive language instruction.

    Science.gov (United States)

    Petursdottir, Anna Ingeborg; Carr, James E

    2011-01-01

    We review recommendations for sequencing instruction in receptive and expressive language objectives in early and intensive behavioral intervention (EIBI) programs. Several books recommend completing receptive protocols before introducing corresponding expressive protocols. However, this recommendation has little empirical support, and some evidence exists that the reverse sequence may be more efficient. Alternative recommendations include teaching receptive and expressive skills simultaneously (M. L. Sundberg & Partington, 1998) and building learning histories that lead to acquisition of receptive and expressive skills without direct instruction (Greer & Ross, 2008). Empirical support for these recommendations also is limited. Future research should assess the relative efficiency of receptive-before-expressive, expressive-before-receptive, and simultaneous training with children who have diagnoses of autism spectrum disorders. In addition, further evaluation is needed of the potential benefits of multiple-exemplar training and other variables that may influence the efficiency of receptive and expressive instruction.

  18. Stigma development and receptivity in almond (Prunus dulcis).

    Science.gov (United States)

    Yi, Weiguang; Law, S Edward; McCoy, Dennis; Wetzstein, Hazel Y

    2006-01-01

    Fertilization is essential in almond production, and pollination can be limiting in production areas. This study investigated stigma receptivity under defined developmental stages to clarify the relationship between stigma morphology, pollen germination, tube growth and fruit set. Light and scanning electron microscopy were employed to examine stigma development at seven stages of flower development ranging from buds that were swollen to flowers in which petals were abscising. Flowers at different stages were hand pollinated and pollen germination and tube growth assessed. Artificial pollinations in the field were conducted to determine the effect of flower age on fruit set. Later stages of flower development exhibited greater stigma receptivity, i.e. higher percentages of pollen germination and more extensive tube growth occurred in older (those opened to the flat petal stage or exhibiting petal fall) than younger flowers. Enhanced stigma receptivity was associated with elongation of stigmatic papillae and increased amounts of stigmatic exudate that inundated papillae at later developmental stages. Field pollinations indicated that the stigma was still receptive and nut set was maintained in older flowers. Stigma receptivity in almond does not become optimal until flowers are past the fully open stage. The stigma is still receptive and fruit set is maintained in flowers even at the stage when petals are abscising. Strategies to enhance pollination and crop yield, including the timing and placement of honey bees, should consider the effectiveness of developmentally advanced flowers.

  19. A Mobile Automated Tomographic Gamma Scanning System - 13231

    Energy Technology Data Exchange (ETDEWEB)

    Kirkpatrick, J.M.; LeBlanc, P.J.; Nakazawa, D.; Petroka, D.L.; Kane Smith, S.; Venkataraman, R.; Villani, M. [Canberra Industries, Inc. 800 Research Parkway, Meriden CT 06450 (United States)

    2013-07-01

    Canberra Industries have recently designed and built a new automated Tomographic Gamma Scanning (TGS) system for mobile deployment. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density, non-heterogeneous matrices. Originally pioneered by R. Estep at Los Alamos National Laboratory (LANL), the TGS method has been further developed and commercialized by Canberra Industries in recent years. The present system advances the state of the art on several fronts: it is designed to be housed in a standard cargo transport container for ease of transport, allowing waste characterization at multiple facilities under the purview of a single operator. Conveyor feed, drum rotator, and detector and collimator positioning mechanisms operated by programmable logic control (PLC) allow automated batch mode operation. The variable geometry settings can accommodate a wide range of waste packaging, including but not limited to standard 220 liter drums, 380 liter overpack drums, and smaller 20 liter cans. A 20 mCi Eu-152 transmission source provides attenuation corrections for drum matrices up to 1 g/cm{sup 3} in TGS mode; the system can be operated in Segmented Gamma Scanning (SGS) mode to measure higher density drums. To support TGS assays at higher densities, the source shield is sufficient to house an alternate Co-60 transmission source of higher activity, up to 250 mCi. An automated shutter and attenuator assembly is provided for operating the system with a dual intensity transmission source. The system's 1500 kg capacity rotator turntable can handle heavy containers such as concrete lined 380 liter overpack drums. Finally, data acquisition utilizes Canberra's Broad Energy Germanium (BEGE) detector and Lynx MCA, with 32 k channels, providing better than 0.1 ke

  20. A system dedicated to the viewing and handling of tomographic images obtained by magnetic resonance

    International Nuclear Information System (INIS)

    Slaets, Joan F.W.; Almeida, Lirio O.B.; Traina, Agma J.M.

    1992-01-01

    The present work describes the development of a dedicated system to be used in visualization and manipulation of a MR images. The graphics environment as well as the tool kit were developed for the dedicated TMS34010 based hardware. The developed software offers a compact kernel with primitives to support the creation and manipulation windows and menus directly in 'C' language. This work is fundamental for the implementation of a user friendly interface build to operate and visualize tomographic images. This tools are essential for the selection an archiving of images planes as used in clinical applications. (author)

  1. 33 CFR 158.310 - Reception facilities: General.

    Science.gov (United States)

    2010-07-01

    ... order to pass the inspection under § 158.160, must— (1) Be a reception facility as defined under § 158... residue; (5) Be capable of receiving NLS residue from an oceangoing ship within 24 hours after notice by that ship of the need for reception facilities; and (6) Be capable of completing the transfer of NLS...

  2. A positron emission tomograph designed for 3/4 mm resolution

    International Nuclear Information System (INIS)

    McInytre, J.A.; Allen, R.D.; Aguiar, J.; Paulson, J.T.

    1995-01-01

    Two factors of the design for a positron tomograph affect the magnitude of the tomograph spatial resolution: the gamma ray detector width and the analogue measurement of the scintillator location. In the tomograph design reported here the analogue measurement is eliminated and the detector transaxial width factor is reduced to 3/4 mm. The analogue measurement is eliminated by transmitting the scintillation light from each individual scintillator through optical fibers to four photo-multipliers (PMT's); the identities of the PMT's then provide a digital address for the scintillation location. Plastic scintillators are used to provide enough scintillation light for transmission through the optical fibers. Bonuses from the use of plastic scintillators are first, the reduction of the scintillator dead time to about 10 nsec, second, a large reduction of cross-talk between neighboring scintillators, third, the reduction of resolution loss from off-axis gamma rays and, fourth, the ability to sample the axial image at one-eighth the axial resolution distance of 2.5 mm. The designed tomograph incorporates 20 rings. Two of the 32 tomograph 20-ring modules have been constructed to measure the resolution and other characteristics of the tomographs

  3. Pipelining Computational Stages of the Tomographic Reconstructor for Multi-Object Adaptive Optics on a Multi-GPU System

    KAUST Repository

    Charara, Ali

    2014-11-01

    The European Extremely Large Telescope project (E-ELT) is one of Europe\\'s highest priorities in ground-based astronomy. ELTs are built on top of a variety of highly sensitive and critical astronomical instruments. In particular, a new instrument called MOSAIC has been proposed to perform multi-object spectroscopy using the Multi-Object Adaptive Optics (MOAO) technique. The core implementation of the simulation lies in the intensive computation of a tomographic reconstruct or (TR), which is used to drive the deformable mirror in real time from the measurements. A new numerical algorithm is proposed (1) to capture the actual experimental noise and (2) to substantially speed up previous implementations by exposing more concurrency, while reducing the number of floating-point operations. Based on the Matrices Over Runtime System at Exascale numerical library (MORSE), a dynamic scheduler drives all computational stages of the tomographic reconstruct or simulation and allows to pipeline and to run tasks out-of order across different stages on heterogeneous systems, while ensuring data coherency and dependencies. The proposed TR simulation outperforms asymptotically previous state-of-the-art implementations up to 13-fold speedup. At more than 50000 unknowns, this appears to be the largest-scale AO problem submitted to computation, to date, and opens new research directions for extreme scale AO simulations. © 2014 IEEE.

  4. Tomographic anthropomorphic models. Pt. 2. Organ doses from computed tomographic examinations in paediatric radiology

    International Nuclear Information System (INIS)

    Zankl, M.; Panzer, W.; Drexler, G.

    1993-11-01

    This report provides a catalogue of organ dose conversion factors resulting from computed tomographic (CT) examinations of children. Two radiation qualities and two exposure geometries were simulated as well as the use of asymmetrical beams. The use of further beam shaping devices was not considered. The organ dose conversion factors are applicable to babies at the age of ca. 2 months and to children between 5 and 7 years but can be used for other ages as well with the appropriate adjustments. For the calculations, the patients were represented by the GSF tomographic anthropomorphic models BABY and CHILD. The radiation transport in the body was simulated using a Monte Carlo method. The doses are presented as conversion factors of mean organ doses per air kerma free in air on the axis of rotation. Mean organ dose conversion factors are given per organ and per scanned body section of 1 cm height. The mean dose to an organ resulting from a particular CT examination can be estimated by summing up the contributions to the organ dose from all relevant sections. To facilitate the selection of the appropriate sections, a table is given which relates the tomographic models' coordinates to certain anatomical landmarks in the human body. (orig.)

  5. Introduction to curved rotary tomographic apparatus 'TOMOREX'

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Shinojima, Masayasu; Kohirasawa, Hideo; Tokui, Mitsuru

    1980-01-01

    In recent years, panorama X-ray photographic method is widely used for the X-ray diagnosis of teeth, jawbones and faces. One type based on the principle of tomography is curved surface rotary tomographic method utilizing fine-gap X-ray beam. With the synchronous rotation of an X-ray tube and a photographic film around a face, describing a U-shaped tomographic plane along a dental arch, an upper or lower jawbone is photographed. In the ''TOMOREX'' belonging to this type, is different tomographic planes are available, so that by selecting any position in advance, the part can be photographed. Furthermore, patients can be subjected to examination as laid on a stretcher. The mechanism and equipment, and the photographic method for eye sockets, cheekbones, upper jaw cavities and stereoscopic images are described. (J.P.N.)

  6. The use of tomographic techniques in the mineral processing Industry. A review

    International Nuclear Information System (INIS)

    Witika, L.K.; Jere, E.H.

    2002-01-01

    Process tomographic techniques may be used to analyse the internal state of most of the multiphase process engineering systems such as material segregation in a reactor multiphase flow in pipes and the spatial resolution of mineral grains in multiphase particles. These techniques include radiation computed tomography (X-ray or ray), electrical methods(capacitance, impedance and inductive tomography) positron emission tomography,optical tomography, microwave tomography, acoustic tomographical methods and many more. Many potential applications exist for process tomographic instrumentation for quantitative analysis and fault-detection purposes. Amongst these, electrical methods are widely used for those mineral processes deserving particular attention such as dense-medium separation, hydro cyclones, flotation cells and columns, gas-liquid absorbers, solvent extraction and other liquid-liquid processes, filtration and other solid-liquid processes, grinding mills (both dry and wet, conveyors and hoppers). Development in on-line measurement instrumentation now allow direct observation of the behaviour of fluids inside mineral separation equipment. This offers the possibility to acquire process data to enable models to be devised, to verify theoretical computational fluid dynamics predictions and control of various unit processes. In this review, the most important tomographic sensing methods are reviewed. Examples of the implementation of some electrical methods are illustrated. (authors)

  7. Self-masking noise subtraction (SMNS) in digital X-ray tomosynthesis for the improvement of tomographic image quality

    International Nuclear Information System (INIS)

    Oh, J.E.; Cho, H.S.; Choi, S.I.; Park, Y.O.; Lee, M.S.; Cho, H.M.; Yang, Y.J.; Je, U.K.; Woo, T.H.; Lee, H.K.

    2011-01-01

    In this paper, we proposed a simple and effective reconstruction algorithm, the so-called self-masking noise subtraction (SMNS), in digital X-ray tomosynthesis to reduce the tomographic blur that is inherent in the conventional tomosynthesis based upon the shift-and-add (SAA) method. Using the SAA and the SMNS algorithms, we investigated the influence of tomographic parameters such as tomographic angle (θ) and angle step (Δθ) on the image quality, measuring the signal-difference-to-noise ratio (SDNR). Our simulation results show that the proposed algorithm seems to be efficient in reducing the tomographic blur and, thus, improving image sharpness. We expect the simulation results to be useful for the optimal design of a digital X-ray tomosynthesis system for our ongoing application of nondestructive testing (NDT).

  8. On the feasibility of tomographic-PIV with low pulse energy illumination in a lifted turbulent jet flame

    Science.gov (United States)

    Boxx, I.; Carter, C. D.; Meier, W.

    2014-08-01

    Tomographic particle image velocimetry (tomographic-PIV) is a recently developed measurement technique used to acquire volumetric velocity field data in liquid and gaseous flows. The technique relies on line-of-sight reconstruction of the rays between a 3D particle distribution and a multi-camera imaging system. In a turbulent flame, however, index-of-refraction variations resulting from local heat-release may inhibit reconstruction and thereby render the technique infeasible. The objective of this study was to test the efficacy of tomographic-PIV in a turbulent flame. An additional goal was to determine the feasibility of acquiring usable tomographic-PIV measurements in a turbulent flame at multi-kHz acquisition rates with current-generation laser and camera technology. To this end, a setup consisting of four complementary metal oxide semiconductor cameras and a dual-cavity Nd:YAG laser was implemented to test the technique in a lifted turbulent jet flame. While the cameras were capable of kHz-rate image acquisition, the laser operated at a pulse repetition rate of only 10 Hz. However, use of this laser allowed exploration of the required pulse energy and thus power for a kHz-rate system. The imaged region was 29 × 28 × 2.7 mm in size. The tomographic reconstruction of the 3D particle distributions was accomplished using the multiplicative algebraic reconstruction technique. The results indicate that volumetric velocimetry via tomographic-PIV is feasible with pulse energies of 25 mJ, which is within the capability of current-generation kHz-rate diode-pumped solid-state lasers.

  9. Minimum Detectable Activity for Tomographic Gamma Scanning System

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Ram [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Smith, Susan [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Kirkpatrick, J. M. [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Croft, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographic Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each “view” is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities

  10. Tomographic array

    International Nuclear Information System (INIS)

    1976-01-01

    The configuration of a tomographic array in which the object can rotate about its axis is described. The X-ray detector is a cylindrical screen perpendicular to the axis of rotation. The X-ray source has a line-shaped focus coinciding with the axis of rotation. The beam is fan-shaped with one side of this fan lying along the axis of rotation. The detector screen is placed inside an X-ray image multiplier tube

  11. New Year’s reception

    CERN Multimedia

    2009-01-01

    At a reception on 28 January, the CERN management presented their best wishes for 2009 to politicians and representatives of the administrations in the local area, and diplomats representing CERN’s Member States, Observer States and other countries.

  12. The reception of Bollywood in Malaysia (1991-2012): a contextual study

    OpenAIRE

    Sreekumar, Rohini

    2017-01-01

    Bollywood films are increasingly drawing scholarly attention for their global appeal and reception. Transnational studies have examined the reception of Bollywood in Australia, Britain, Scotland, South Africa, Russia, the United States of America, Bangladesh and Nepal. However, academic work on the Southeast Asian reception of these films is scarcer. This research seeks to fill this gap by looking at the reception of Bollywood in Malaysia from 1991-2012. The thesis adopts a...

  13. HFSB-seeding for large-scale tomographic PIV in wind tunnels

    Science.gov (United States)

    Caridi, Giuseppe Carlo Alp; Ragni, Daniele; Sciacchitano, Andrea; Scarano, Fulvio

    2016-12-01

    A new system for large-scale tomographic particle image velocimetry in low-speed wind tunnels is presented. The system relies upon the use of sub-millimetre helium-filled soap bubbles as flow tracers, which scatter light with intensity several orders of magnitude higher than micron-sized droplets. With respect to a single bubble generator, the system increases the rate of bubbles emission by means of transient accumulation and rapid release. The governing parameters of the system are identified and discussed, namely the bubbles production rate, the accumulation and release times, the size of the bubble injector and its location with respect to the wind tunnel contraction. The relations between the above parameters, the resulting spatial concentration of tracers and measurement of dynamic spatial range are obtained and discussed. Large-scale experiments are carried out in a large low-speed wind tunnel with 2.85 × 2.85 m2 test section, where a vertical axis wind turbine of 1 m diameter is operated. Time-resolved tomographic PIV measurements are taken over a measurement volume of 40 × 20 × 15 cm3, allowing the quantitative analysis of the tip-vortex structure and dynamical evolution.

  14. Terahertz wave tomographic imaging with a Fresnel lens

    Institute of Scientific and Technical Information of China (English)

    S. Wang; X.-C. Zhang

    2003-01-01

    We demonstrate three-dimensional tomographic imaging using a Fresnel lens with broadband terahertz pulses. Objects at various locations along the beam propagation path are uniquely imaged on the same imaging plane using a Fresnel lens with different frequencies of the imaging beam. This procedure allows the reconstruction of an object's tomographic contrast image by assembling the frequency-dependent images.

  15. Current Writing: Text and Reception in Southern Africa: Advanced ...

    African Journals Online (AJOL)

    Current Writing: Text and Reception in Southern Africa: Advanced Search. Journal Home > Current Writing: Text and Reception in Southern Africa: Advanced Search. Log in or Register to get access to full text downloads.

  16. Morning Receptions in a Danish ECE Context

    DEFF Research Database (Denmark)

    Kornerup, Ida; Gravgaard, Mette Lykke

    This paper focus on a special pedagogical context; morning receptions as a learning environment. The studies of mornings are part of a 3 year long research project in which different types of learning environments were investigated. Few studies have researched morning receptions in this perspecti...... even though pedagogues often emphasize that this particular pedagogical context have implications on the children’s wellbeing and learning possibilities throughout the day....

  17. Processing of acquisition data for a time of flight positron tomograph

    International Nuclear Information System (INIS)

    Robert, G.

    1987-10-01

    After a review of basic principles concerning the time of flight positron tomography, the LETI positron tomograph is briefly described. For performance optimization (acquisition, calibration, image reconstruction), various specialized operators have been designed: the realization of the acquisition system is presented [fr

  18. Comparison of Measures of E-cigarette Advertising Exposure and Receptivity.

    Science.gov (United States)

    Pokhrel, Pallav; Fagan, Pebbles; Herzog, Thaddeus A; Schmid, Simone; Kawamoto, Crissy T; Unger, Jennifer B

    2017-10-01

    We tested how various measures of e-cigarette advertising exposure and receptivity are related to each other and compare to each other in their associations with e-cigarette use susceptibility and behavior. Cross-sectional data were collected from young adult college students (N = 470; M age = 20.9, SD = 2.1; 65% women). Measures of e-cigarette advertising exposure/receptivity compared included a cued recall measure, measures of marketing receptivity, perceived ad exposure, liking of e-cigarette ads, and frequency of convenience store visit, which is considered a measure of point-of-sale ad exposure. The cued-recall measure was associated with e-cigarette use experimentation but not current e-cigarette use. Marketing receptivity was associated with current e-cigarette use but not e-cigarette use experimentation. Liking of e-cigarette ads was the only measure associated with e-cigarette use susceptibility. Frequency of convenience store visit was associated with current e-cigarette use but not e-cigarette use experimentation or susceptibility. Inclusion of multiple measures of marketing exposure and receptivity is recommended for regulatory research concerning e-cigarette marketing. Marketing receptivity and cued recall measures are strong correlates of current and ever e-cigarette use, respectively.

  19. Central nervous system leukemia and lymphoma: computed tomographic manifestations

    International Nuclear Information System (INIS)

    Pagani, J.J.; Libshitz, H.I.; Wallace, S.; Hayman, L.A.

    1981-01-01

    Computed tomographic (CT) abnormalities in the brain were identified in 31 of 405 patients with leukemia or lymphoma. Abnormalities included neoplastic masses (15), hemorrhage (nine), abscess (two), other brain tumors (four), and methotrexate leukoencephalopathy (one). CT was normal in 374 patients including 148 with meningeal disease diagnosed by cerebrospinal fluid cytologic examination. Prior to treatment, malignant masses were isodense or of greater density with varying amounts of edema. Increase in size or number of the masses indicated worsening. Response to radiation and chemotherapy was manifested by development of a central low density region with an enhancing rim. CT findings correlated with clinical and cerebrospinal fluid findings. The differential diagnosis of the various abnormalities is considered

  20. A Reception Analysis on the Youth Audiences of TV Series in Marivan

    Directory of Open Access Journals (Sweden)

    Omid Karimi

    2014-03-01

    Full Text Available The aim of this article is to describe the role of foreign media as the agitators of popular culture. For that with reception analysis it’s pay to describe decoding of youth audiences about this series. Globalization theory and Reception in Communication theory are formed the theoretical system of current article. The methodology in this research is qualitative one, and two techniques as in-depth interview and observation are used for data collection. The results show different people based on individual features, social and cultural backgrounds have inclination toward special characters and identify with them. This inclination so far the audience fallow the series because of his/her favorite character. Also there is a great compatibility between audience backgrounds and their receptions. A number of audience have criticized the series and point out the negative consequences on its society. However, seeing the series continue; really they prefer watching series enjoying to risks of it.

  1. Arbitrary layer tomographic method and apparatus

    International Nuclear Information System (INIS)

    Kato, H.; Ishida, M.

    1984-01-01

    Many two-dimensional X-ray projection distribution images obtained by exposing an object to X-rays in various directions are once stored in positions different from one another in a stimulable phosphor sheet or respectively in many stimulable phosphor sheets. The stimulable phosphor sheet or sheets are then scanned with stimulating rays, and the light emitted thereby from the stimulable phosphor sheet or sheets is photoelectrically read out to obtain electric signals representing the X-ray projection distribution images. The electric signals are processed to obtain a tomographic image of an arbitrary tomographic layer of the object

  2. Spontaneous Intracerebral Hemorrhage: Computed Tomographic Characteristics and Outcome

    Directory of Open Access Journals (Sweden)

    Aimara de la Caridad Vergara Santos

    2015-12-01

    Full Text Available Background: strokes are the third leading cause of death among adults and 10-15 % of them are due to spontaneous intracerebral hemorrhage. Objective: to characterize spontaneous intracerebral hemorrhage through computed tomography scan and its outcome. Methods: a case series study was conducted comprising patients diagnosed with spontaneous intracerebral hemorrhage admitted to the Arnaldo Milián Castro Provincial University Hospital in Villa Clara from January 2009 to January 2010. Tomographic variables of interest were derived from evaluation of spontaneous intracerebral hematomas. Results: fifty-nine cases of spontaneous intracerebral hemorrhage were studied, 23 were located in lobar regions, 4 had severe midline shift, and 2 showed volume greater than 80 ml. Eight out of eleven with extension into the ventricular system had an unfavorable outcome. Among those with thalamic hemorrhage, patients with diameter larger than 4cm and extension into the ventricular system died. Patients with putaminal hemorrhage larger than 4 cm and posterior fossa hematoma with hydrocephalus had a poor outcome, as well as most individuals (55 with other mass effects. Most lobar hematomas (14 out of 23 had a satisfactory outcome, unlike cerebellar and brainstem hematomas. Conclusions: tomographic variables that had a negative impact on the outcome were: volume greater than 80 ml, severe midline shift, diameter larger than 4 cm, extension into the ventricular system, hydrocephalus, other signs of mass effect and brainstem location.

  3. Tomographic Approach in Three-Orthogonal-Basis Quantum Key Distribution

    International Nuclear Information System (INIS)

    Liang Wen-Ye; Yin Zhen-Qiang; Chen Hua; Li Hong-Wei; Chen Wei; Han Zheng-Fu; Wen Hao

    2015-01-01

    At present, there is an increasing awareness of some three-orthogonal-basis quantum key distribution protocols, such as, the reference-frame-independent (RFI) protocol and the six-state protocol. For secure key rate estimations of these protocols, there are two methods: one is the conventional approach, and another is the tomographic approach. However, a comparison between these two methods has not been given yet. In this work, with the general model of rotation channel, we estimate the key rate using conventional and tomographic methods respectively. Results show that conventional estimation approach in RFI protocol is equivalent to tomographic approach only in the case of that one of three orthogonal bases is always aligned. In other cases, tomographic approach performs much better than the respective conventional approaches of the RFI protocol and the six-state protocol. Furthermore, based on the experimental data, we illustrate the deep connections between tomography and conventional RFI approach representations. (paper)

  4. Radiographic test phantom for computed tomographic lung nodule analysis

    International Nuclear Information System (INIS)

    Zerhouni, E.A.

    1987-01-01

    This patent describes a method for evaluating a computed tomograph scan of a nodule in a lung of a human or non-human animal. The method comprises generating a computer tomograph of a transverse section of the animal containing lung and nodule tissue, and generating a second computer tomograph of a test phantom comprising a device which simulates the transverse section of the animal. The tissue simulating portions of the device are constructed of materials having radiographic densities substantially identical to those of the corresponding tissue in the simulated transverse section of the animal and have voids therein which simulate, in size and shape, the lung cavities in the transverse section and which contain a test reference nodule constructed of a material of predetermined radiographic density which simulates in size, shape and position within a lung cavity void of the test phantom the nodule in the transverse section of the animal and comparing the respective tomographs

  5. Receptivity of Hypersonic Boundary Layers to Distributed Roughness and Acoustic Disturbances

    Science.gov (United States)

    Balakumar, P.

    2013-01-01

    Boundary-layer receptivity and stability of Mach 6 flows over smooth and rough seven-degree half-angle sharp-tipped cones are numerically investigated. The receptivity of the boundary layer to slow acoustic disturbances, fast acoustic disturbances, and vortical disturbances is considered. The effects of three-dimensional isolated roughness on the receptivity and stability are also simulated. The results for the smooth cone show that the instability waves are generated in the leading edge region and that the boundary layer is much more receptive to slow acoustic waves than to the fast acoustic waves. Vortical disturbances also generate unstable second modes, however the receptivity coefficients are smaller than that of the slow acoustic wave. Distributed roughness elements located near the nose region decreased the receptivity of the second mode generated by the slow acoustic wave by a small amount. Roughness elements distributed across the continuous spectrum increased the receptivity of the second mode generated by the slow and fast acoustic waves and the vorticity wave. The largest increase occurred for the vorticity wave. Roughness elements distributed across the synchronization point did not change the receptivity of the second modes generated by the acoustic waves. The receptivity of the second mode generated by the vorticity wave increased in this case, but the increase is lower than that occurred with the roughness elements located across the continuous spectrum. The simulations with an isolated roughness element showed that the second mode waves generated by the acoustic disturbances are not influenced by the small roughness element. Due to the interaction, a three-dimensional wave is generated. However, the amplitude is orders of magnitude smaller than the two-dimensional wave.

  6. Analysis and databasing software for integrated tomographic gamma scanner (TGS) and passive-active neutron (PAN) assay systems

    International Nuclear Information System (INIS)

    Estep, R.J.; Melton, S.G.; Buenafe, C.

    2000-01-01

    The CTEN-FIT program, written for Windows 9x/NT in C++,performs databasing and analysis of combined thermal/epithermal neutron (CTEN) passive and active neutron assay data and integrates that with isotopics results and gamma-ray data from methods such as tomographic gamma scanning (TGS). The binary database is reflected in a companion Excel database that allows extensive customization via Visual Basic for Applications macros. Automated analysis options make the analysis of the data transparent to the assay system operator. Various record browsers and information displays simplify record keeping tasks

  7. First experience with a mobile computed tomograph in the USSR

    International Nuclear Information System (INIS)

    Portnoj, L.M.

    1989-01-01

    Utilization experience of mobile computerized tomograph mounted in the bus is presented. Problems concerning staff, selection of medical base institutes etc are considered. Efficiency of mobile computerized tomographes in revealing different diseases is pointed out

  8. The Comparative Reception of Darwinism: A Brief History

    Science.gov (United States)

    Glick, Thomas F.

    2010-01-01

    The subfield of Darwin studies devoted to comparative reception coalesced around 1971 with the planning of a conference on the subject, at the University of Texas at Austin held in April 1972. The original focus was western Europe, Russia and the United States. Subsequently a spate of studies on the Italian reception added to the Eurocentric…

  9. TomoBank: a tomographic data repository for computational x-ray science

    Science.gov (United States)

    De Carlo, Francesco; Gürsoy, Doğa; Ching, Daniel J.; Joost Batenburg, K.; Ludwig, Wolfgang; Mancini, Lucia; Marone, Federica; Mokso, Rajmund; Pelt, Daniël M.; Sijbers, Jan; Rivers, Mark

    2018-03-01

    There is a widening gap between the fast advancement of computational methods for tomographic reconstruction and their successful implementation in production software at various synchrotron facilities. This is due in part to the lack of readily available instrument datasets and phantoms representative of real materials for validation and comparison of new numerical methods. Recent advancements in detector technology have made sub-second and multi-energy tomographic data collection possible (Gibbs et al 2015 Sci. Rep. 5 11824), but have also increased the demand to develop new reconstruction methods able to handle in situ (Pelt and Batenburg 2013 IEEE Trans. Image Process. 22 5238-51) and dynamic systems (Mohan et al 2015 IEEE Trans. Comput. Imaging 1 96-111) that can be quickly incorporated in beamline production software (Gürsoy et al 2014 J. Synchrotron Radiat. 21 1188-93). The x-ray tomography data bank, tomoBank, provides a repository of experimental and simulated datasets with the aim to foster collaboration among computational scientists, beamline scientists, and experimentalists and to accelerate the development and implementation of tomographic reconstruction methods for synchrotron facility production software by providing easy access to challenging datasets and their descriptors.

  10. Computed tomographic findings of intracranial pyogenic abscess

    International Nuclear Information System (INIS)

    Kim, S. J.; Suh, J. H.; Park, C. Y.; Lee, K. C.; Chung, S. S.

    1982-01-01

    The early diagnosis and effective treatment of brain abscess pose a difficult clinical problem. With the advent of computed tomography, however, it appears that mortality due to intracranial abscess has significantly diminished. 54 cases of intracranial pyogenic abscess are presented. Etiologic factors and computed tomographic findings are analyzed and following result are obtained. 1. The common etiologic factors are otitis media, post operation, and head trauma, in order of frequency. 2. The most common initial computed tomographic findings of brain abscess is ring contrast enhancement with surrounding brain edema. 3. The most characteristic computed tomographic finding of ring contrast enhancement is smooth thin walled ring contrast enhancement. 4. Most of thick irregular ring contrast enhancement are abscess associated with cyanotic heart disease or poor operation. 5. The most common findings of epidural and subdural empyema is crescentic radiolucent area with thin wall contrast enhancement without surrounding brain edema in convexity of brain

  11. Studies of discrete symmetries in a purely leptonic system using the Jagiellonian Positron Emission Tomograph

    Directory of Open Access Journals (Sweden)

    Moskal P.

    2016-01-01

    Full Text Available Discrete symmetries such as parity (P, charge-conjugation (C and time reversal (T are of fundamental importance in physics and cosmology. Breaking of charge conjugation symmetry (C and its combination with parity (CP constitute necessary conditions for the existence of the asymmetry between matter and antimatter in the observed Universe. The presently known sources of discrete symmetries violations can account for only a tiny fraction of the excess of matter over antimatter. So far CP and T symmetries violations were observed only for systems involving quarks and they were never reported for the purely leptonic objects. In this article we describe briefly an experimental proposal for the test of discrete symmetries in the decays of positronium atom which is made exclusively of leptons. The experiments are conducted by means of the Jagiellonian Positron Emission Tomograph (J-PET which is constructed from strips of plastic scintillators enabling registration of photons from the positronium annihilation. J-PET tomograph together with the positronium target system enable to measure expectation values for the discrete symmetries odd operators constructed from (i spin vector of the ortho-positronium atom, (ii momentum vectors of photons originating from the decay of positronium, and (iii linear polarization direction of annihilation photons. Linearly polarized positronium will be produced in the highly porous aerogel or polymer targets, exploiting longitudinally polarized positrons emitted by the sodium 22Na isotope. Information about the polarization vector of orthopositronium will be available on the event by event basis and will be reconstructed from the known position of the positron source and the reconstructed position of the orthopositronium annihilation. In 2016 the first tests and calibration runs are planned, and the data collection with high statistics will commence in the year 2017.

  12. Combination tomographic and cardiographic ultrasonic imaging method and system

    International Nuclear Information System (INIS)

    Yano, T.; Fukukita, H.; Fukumoto, A.; Hayakawa, Y.; Irioka, K.

    1984-01-01

    Ultrasonic echo signals are successively sampled and converted to digital echo data which are written into a first digital memory column by column and then read out row by row into a first buffer memory. The digital echo data which are derived in response to beams successively transmitted in a predetermined direction are written into columns of a second digital memory and read out of the memory in rows into a second buffer memory. The data stored in the first and second buffer memories are read out for digital-to-analog conversion and selectively applied within a television ''frame'' interval to control electron beam intensity of a single cathode ray tube so as to present tomographic and cardiographic images in different display areas of the tube

  13. Genetic and non-genetic factors affecting rabbit doe sexual receptivity as estimated from one generation of divergent selection

    Directory of Open Access Journals (Sweden)

    M. Theau.Clément

    2015-09-01

    Full Text Available Sexual receptivity of rabbit does at insemination greatly influences fertility and is generally induced by hormones or techniques known as “biostimulation”. Searching for more sustainable farming systems, an original alternative would be to utilise the genetic pathway to increase the does’receptivity. The purpose of the present study was to identify genetic and non-genetic factors that influence rabbit doe sexual receptivity, in the context of a divergent selection experiment over 1 generation. The experiment spanned 2 generations: the founder generation (G0 consisting of 140 rabbit does, and the G1 generation comprising 2 divergently selected lines (L and H lines with 70 does each and 2 successive batches from each generation. The selection rate of the G0 females to form the G1 lines was 24/140. The selection tests consisted of 16 to 18 successive receptivity tests at the rate of 3 tests per week. On the basis of 4716 tests from 275 females, the average receptivity was 56.6±48.2%. A batch effect and a test operator effect were revealed. The contribution of females to the total variance was 20.0%, whereas that of bucks was only 1.1%. Throughout the experiment, 18.2% of does expressed a low receptivity (< 34%, 50.7% a medium one and 33.1% a high one (>66%. Some does were frequently receptive, whereas others were rarely receptive. The repeatability of sexual receptivity was approximately 20%. The results confirmed the high variability of sexual receptivity of non-lactating rabbit does maintained without any biostimulation or hormonal treatment. A lack of selection response on receptivity was observed. Accordingly, the heritability of receptivity was estimated at 0.01±0.02 from an animal model and at 0.02±0.03 from a  sire and dam model. The heritability of the average receptivity of a doe was calculated as 0.04. In agreement with the low estimated heritability, the heritability determined was no different from zero

  14. Measuring receptive collocational competence across proficiency levels

    Directory of Open Access Journals (Sweden)

    Déogratias Nizonkiza

    2015-12-01

    Full Text Available The present study investigates, (i English as Foreign Language (EFL learners’ receptive collocational knowledge growth in relation to their linguistic proficiency level; (ii how much receptive collocational knowledge is acquired as proficiency develops; and (iii the extent to which receptive knowledge of collocations of EFL learners varies across word frequency bands. A proficiency measure and a collocation test were administered to English majors at the University of Burundi. Results of the study suggest that receptive collocational competence develops alongside EFL learners’ linguistic proficiency; which lends empirical support to Gyllstad (2007, 2009 and Author (2011 among others, who reported similar findings. Furthermore, EFL learners’ collocations growth seems to be quantifiable wherein both linguistic proficiency level and word frequency occupy a crucial role. While more gains in terms of collocations that EFL learners could potentially add as a result of change in proficiency are found at lower levels of proficiency; collocations of words from more frequent word bands seem to be mastered first, and more gains are found at more frequent word bands. These results confirm earlier findings on the non-linearity nature of vocabulary growth (cf. Meara 1996 and the fundamental role played by frequency in word knowledge for vocabulary in general (Nation 1983, 1990, Nation and Beglar 2007, which are extended here to collocations knowledge.

  15. THE AUDIT OF RECEPTION PROCESS

    Directory of Open Access Journals (Sweden)

    Dorina MOCUŢA

    2013-01-01

    Full Text Available The object of study case is to analyze the quality of the logistics department, focusing on the audit process. Purpose of this paper is to present the advantages resulting from the systematic audit processes and methods of analysis and improvement of nonconformities found. The case study is realised at SC Miele Tehnica SRL Brasov, twelfth production line, and the fourth from outside Germany. The specific objectives are: clarifying the concept of audit quality, emphasizing requirements ISO 19011:2003 "Guidelines for auditing quality management systems and / or environment" on audits; cchieving quality audit and performance analysis; improved process performance reception materials; compliance with legislation and auditing standards applicable in EU and Romania.

  16. Developing Reception Competence in Children with a Mild Intellectual Disability

    Directory of Open Access Journals (Sweden)

    Ana Koritnik

    2015-06-01

    Full Text Available The paper presents research paradigms which study factors that allow influencing the language development of children with mild intellectual disabilities to the greatest extent possible. Special attention is dedicated to the development of the reception competence with the use of reception didactics methods based on a relatively frequent use of less demanding non-language semiotic functions. The core of the paper presents results of an experimental case study (on a sample of five children with a mild intellectual disability over a one school year period, through which the reception competence in these children was developed with a systematic use of an adapted communication model of literary education as an experimental factor. The results have confirmed the initially set hypothesis about reception progress.

  17. Data acquisition system for a positron tomograph using time-of-flight information

    International Nuclear Information System (INIS)

    Bertin, Francois.

    1981-12-01

    Progress in nuclear instrumentation has led to the development of scintillators much faster than the NaI crystal traditionally used in nuclear medicine. As a result it is now possible to measure time-of-flight, i.e. the time between the arrival of two γ rays emitted in coincidence on two detectors. With this extra information the β + annihilation site may be located. The introduction of time-of-flight in tomographic techniques called for research along two lines: - ''theoretical'' research leading to the creation of a new image reconstruction algorithm taking into account time-of-flight information - applied research leading to the development of an efficient measurement line and sophisticated data acquisition and processing electronics. This research has been carried out at LETI and is briefly outlined in chapter I. Chapter II shows how the introduction of time-of-flight and the modification of the reconstruction algorithm complicate the electronic and informatic equipment of the tomograph. Several acquisition and processing strategies are proposed, then the need to use an intermediate mass storage and hence to design a complex acquisition operator is demonstrated. Chapter III examines the structure of the acquisition operator and the resulting block diagram is presented in detail in chapter IV [fr

  18. Food in film : a study on audience reception

    OpenAIRE

    Civelek, Ece Simin

    2012-01-01

    Ankara : The Department of Communication and Design, İhsan Doğramacı Bilkent University, 2012. Thesis (Master's) -- Bilkent University, 2012. Includes bibliographical references leaves 140-149. This study intends to analyze audience reception of foodstuff and related practices in films. In the study foodstuff and related practices are taken into consideration as a powerful semiotic system and in that respect are evaluated as an important property of filmic narration. Study e...

  19. Tomographic apparatus for reconstructing planar slices from non-absorbed and non-scattered radiation

    International Nuclear Information System (INIS)

    1980-01-01

    Apparatus which can be used in computerized tomographic systems for producing a fan shaped beam, detectors to be used in conjunction with the source and equipment for rotating the source supports are described. (U.K.)

  20. A study of the decoding of multiple pinhole coded aperture RI tomographic images

    International Nuclear Information System (INIS)

    Hasegawa, Takeo; Kobayashi, Akitoshi; Nishiyama, Yutaka

    1980-01-01

    The authors constructed a Multiple Pinhole Coded Aperture (MPCA) and developed related decoding software. When simple coordinate transformation was performed, omission of points and shifting of counts occurred. By selecting various tomographic planes and collecting count for each tomographic depth from the shadowgram, a solution to these problems was found. The counts from the central portion of the tomographic image from the MPCA were incorrectly high, this was rectified by a correction function to improve the uniformity correction program of the γ-camera. Depth resolution of the tomographic image improved in proportion to the area encompassed by the pinhole configuration. An MPCA with a uniform arrangement of pinholes (e, g, pinholes in an arrangement parallel to the X-axis or the Y-axis) yielded decoded tomographic images of inferior quality. Optimum results were obtained with a ring-shaped arrangement yielding clinically applicable tomographic images even for large objects. (author)

  1. The Early Literary Reception of Ernest Hemingway in Iran

    Directory of Open Access Journals (Sweden)

    Atefeh Ghasemnejad

    2018-01-01

    Full Text Available This essay investigates the dynamics that led to the literary reception of Ernest Hemingway before the Islamic Revolution in Iran. This article deploys reception studies as a branch of Comparative Literature with a focus upon conceptions of Siegbert Salomon Prawer and the practical method of George Asselineau to unearth the ideological, political, and historical milieu that embraced Hemingway’s literary fortune in Iran. This investigation, unprecedented in the study of Iranian literature, discusses how and why Hemingway was initially received in Iran. As such, the inception of literary fortune of Ernest Hemingway in Iran is examined by the contextual features, Persian literary taste, and the translator’s incentives that paved the way for this reception. This article also uncovers the reasons for the delay in the literary reception of Hemingway in Iran and discussed why some of Hemingway’s oeuvres enjoyed recognition while others were neglected by the Iranian readership.

  2. Expressive and receptive language skills in preschool children from a socially disadvantaged area.

    Science.gov (United States)

    Ryan, Ashling; Gibbon, Fiona E; O'shea, Aoife

    2016-02-01

    Evidence suggests that children present with receptive language skills that are equivalent to or more advanced than expressive language skills. This profile holds true for typical and delayed language development. This study aimed to determine if such a profile existed for preschool children from an area of social deprivation and to investigate if particular language skills influence any differences found between expressive and receptive skills. Data from 187 CELF P2 UK assessments conducted on preschool children from two socially disadvantaged areas in a city in southern Ireland. A significant difference was found between Receptive Language Index (RLI) and Expressive Language Index (ELI) scores with Receptive scores found to be lower than Expressive scores. The majority (78.6%) of participants had a lower Receptive Language than Expressive score (RLI ELI), with very few (3.2%) having the same Receptive and Expressive scores (RLI = ELI). Scores for the Concepts and Following Directions (receptive) sub-test were significantly lower than for the other receptive sub tests, while scores for the Expressive Vocabulary sub-test were significantly higher than for the other expressive sub tests. The finding of more advanced expressive than receptive language skills in socially deprived preschool children is previously unreported and clinically relevant for speech-language pathologists in identifying the needs of this population.

  3. Estimation of spatial uncertainties of tomographic velocity models

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, M.; Du, Z.; Querendez, E. [SINTEF Petroleum Research, Trondheim (Norway)

    2012-12-15

    This research project aims to evaluate the possibility of assessing the spatial uncertainties in tomographic velocity model building in a quantitative way. The project is intended to serve as a test of whether accurate and specific uncertainty estimates (e.g., in meters) can be obtained. The project is based on Monte Carlo-type perturbations of the velocity model as obtained from the tomographic inversion guided by diagonal and off-diagonal elements of the resolution and the covariance matrices. The implementation and testing of this method was based on the SINTEF in-house stereotomography code, using small synthetic 2D data sets. To test the method the calculation and output of the covariance and resolution matrices was implemented, and software to perform the error estimation was created. The work included the creation of 2D synthetic data sets, the implementation and testing of the software to conduct the tests (output of the covariance and resolution matrices which are not implicitly provided by stereotomography), application to synthetic data sets, analysis of the test results, and creating the final report. The results show that this method can be used to estimate the spatial errors in tomographic images quantitatively. The results agree with' the known errors for our synthetic models. However, the method can only be applied to structures in the model, where the change of seismic velocity is larger than the predicted error of the velocity parameter amplitudes. In addition, the analysis is dependent on the tomographic method, e.g., regularization and parameterization. The conducted tests were very successful and we believe that this method could be developed further to be applied to third party tomographic images.

  4. Generalized Row-Action Methods for Tomographic Imaging

    DEFF Research Database (Denmark)

    Andersen, Martin Skovgaard; Hansen, Per Christian

    2014-01-01

    Row-action methods play an important role in tomographic image reconstruction. Many such methods can be viewed as incremental gradient methods for minimizing a sum of a large number of convex functions, and despite their relatively poor global rate of convergence, these methods often exhibit fast...... initial convergence which is desirable in applications where a low-accuracy solution is acceptable. In this paper, we propose relaxed variants of a class of incremental proximal gradient methods, and these variants generalize many existing row-action methods for tomographic imaging. Moreover, they allow...

  5. Membrane–initiated estradiol signaling regulating sexual receptivity

    Directory of Open Access Journals (Sweden)

    Paul E Micevych

    2011-09-01

    Full Text Available Estradiol has profound actions on the structure and function of the nervous system. In addition to nuclear actions that directly modulate gene expression, the idea that estradiol can rapidly activate cell signaling by binding to membrane estrogen receptors (mERs has emerged. Even the regulation of sexual receptivity, an action previously thought to be completely regulated by nuclear ERs, has been shown to have a membrane-initiated estradiol signaling (MIES component. This highlighted the question of the nature of mERs. Several candidates have been proposed, ERα, ERβ, ER-X, GPR30 (G protein coupled estrogen receptor; GPER, and a receptor activated by a diphenylacrylamide compound, STX. Although each of these receptors has been shown to be active in specific assays, we present evidence for and against their participation in sexual receptivity by acting in the lordosis-regulating circuit. The initial MIES that activates the circuit is in the arcuate nucleus of the hypothalamus (ARH. Using both activation of μ-opioid receptors (MOR in the medial preoptic nucleus and lordosis behavior, we document that both ERα and the STX receptor participate in the required MIES. ERα and the STX receptor activation of cell signaling are dependent on the transactivation of type 1 metabotropic glutamate receptors (mGluR1a that augment progesterone synthesis in astrocytes and protein kinase C (PKC in ARH neurons. While estradiol-induced sexual receptivity does not depend on neuroprogesterone, proceptive behaviors do. Moreover, the ERα and the STX receptor activation of medial preoptic MORs and augmentation of lordosis were sensitive to mGluR1a blockade. These observations suggest a common mechanism through which mERs are coupled to intracellular signaling cascades, not just in regulating reproduction, but in actions throughout the neuraxis including the cortex, hippocampus, striatum and DRGs.

  6. Membrane-Initiated Estradiol Signaling Regulating Sexual Receptivity

    Science.gov (United States)

    Micevych, Paul E.; Dewing, Phoebe

    2011-01-01

    Estradiol has profound actions on the structure and function of the nervous system. In addition to nuclear actions that directly modulate gene expression, the idea that estradiol can rapidly activate cell signaling by binding to membrane estrogen receptors (mERs) has emerged. Even the regulation of sexual receptivity, an action previously thought to be completely regulated by nuclear ERs, has been shown to have a membrane-initiated estradiol signaling (MIES) component. This highlighted the question of the nature of mERs. Several candidates have been proposed, ERα, ERβ, ER-X, GPR30 (G protein coupled estrogen receptor), and a receptor activated by a diphenylacrylamide compound, STX. Although each of these receptors has been shown to be active in specific assays, we present evidence for and against their participation in sexual receptivity by acting in the lordosis-regulating circuit. The initial MIES that activates the circuit is in the arcuate nucleus of the hypothalamus (ARH). Using both activation of μ-opioid receptors (MOR) in the medial preoptic nucleus and lordosis behavior, we document that both ERα and the STX-receptor participate in the required MIES. ERα and the STX-receptor activation of cell signaling are dependent on the transactivation of type 1 metabotropic glutamate receptors (mGluR1a) that augment progesterone synthesis in astrocytes and protein kinase C (PKC) in ARH neurons. While estradiol-induced sexual receptivity does not depend on neuroprogesterone, proceptive behaviors do. Moreover, the ERα and the STX-receptor activation of medial preoptic MORs and augmentation of lordosis were sensitive to mGluR1a blockade. These observations suggest a common mechanism through which mERs are coupled to intracellular signaling cascades, not just in regulating reproduction, but in actions throughout the neuraxis including the cortex, hippocampus, striatum, and dorsal root ganglias. PMID:22649369

  7. A 2 x 2 imaging MIMO system based on LED Visible Light Communications employing space balanced coding and integrated PIN array reception

    DEFF Research Database (Denmark)

    Li, Jiehui; Xu, Yinfan; Shi, Jianyang

    2016-01-01

    In this paper, we proposed a 2 x 2 imaging Multi-Input Multi-Output (MIMO)-Visible Light Communication (VLC) system by employing Space Balanced Coding (SBC) based on two RGB LEDs and integrated PIN array reception. We experimentally demonstrated 1.4-Gbit/s VLC transmission at a distance of 2.5 m...

  8. Tomographs based on non-conventional radiation sources and methods

    International Nuclear Information System (INIS)

    Barbuzza, R.; Fresno, M. del; Venere, Marcelo J.; Clausse, Alejandro; Moreno, C.

    2000-01-01

    Computer techniques for tomographic reconstruction of objects X-rayed with a compact plasma focus (PF) are presented. The implemented reconstruction algorithms are based on stochastic searching of solutions of Radon equation, using Genetic Algorithms and Monte Carlo methods. Numerical experiments using actual projections were performed concluding the feasibility of the application of both methods in tomographic reconstruction problem. (author)

  9. Radiographic and tomographic study of the elbow joint in dogs

    International Nuclear Information System (INIS)

    Sendyk-Grunkraut, Alessandra; Martin, Claudia M.; Souza, Alexandre N.A.; Patricio, Geni Cristina F.; Lorigados, Carla A.B.; Matera, Julia M.; Fonseca-Pinto, Ana C.B.C.

    2017-01-01

    Elbow dysplasia disease includes an united anconeal process, fragmented medial coronoid process, osteochondrosis of humeral trochlea, articular incongruity and degenerative joint disease. The aim of this study was to present detailed morphologic and morphometric aspects of the elbow joint in dog in clinical and correlate with radiographic and tomographic (CT) exam. Inter-observer variation for articular incongruity measurements by CT, comparative analysis in the radiographic exam, angle in ulnar notch and its comparative analysis between radiographic and tomographic agreement examination in 44 elbow of dogs with different ages were evaluated. The statistics analyses included the kappa coefficient and interclass correlation and Fischer's test and McNemar's test. It was evidenced that individual performance of each radiographic incidence had poor agreement with the tomographic exam, suggesting that the accomplishment of more than two radiograph views are needed. There was no agreement between the three evaluators in the ulnar notch angle at radiographic and tomographic exams. However, there was good/moderate agreement for articular incongruity measurement in the sagittal plane between evaluators. It was possible to conclude that none of the five radiographic incidences was better than the others for radiographic analysis because each incidence had a better identification of a particular elbow compartment; measurements at the tomographic exam to evaluate radioulnar incongruity had no reproductiveness in the frontal plane, but in sagittal plan had a good/moderate agreement between observers and the angle in ulnar notch presented no repeatability at radiographic exam and no reproductiveness at tomographic exam. (author)

  10. An examination of the concept of driving point receptance

    Science.gov (United States)

    Sheng, X.; He, Y.; Zhong, T.

    2018-04-01

    In the field of vibration, driving point receptance is a well-established and widely applied concept. However, as demonstrated in this paper, when a driving point receptance is calculated using the finite element (FE) method with solid elements, it does not converge as the FE mesh becomes finer, suggesting that there is a singularity. Hence, the concept of driving point receptance deserves a rigorous examination. In this paper, it is firstly shown that, for a point harmonic force applied on the surface of an elastic half-space, the Boussinesq formula can be applied to calculate the displacement amplitude of the surface if the response point is sufficiently close to the load. Secondly, by applying the Betti reciprocal theorem, it is shown that the displacement of an elastic body near a point harmonic force can be decomposed into two parts, with the first one being the displacement of an elastic half-space. This decomposition is useful, since it provides a solid basis for the introduction of a contact spring between a wheel and a rail in interaction. However, according to the Boussinesq formula, this decomposition also leads to the conclusion that a driving point receptance is infinite (singular), and would be undefinable. Nevertheless, driving point receptances have been calculated using different methods. Since the singularity identified in this paper was not appreciated, no account was given to the singularity in these calculations. Thus, the validity of these calculation methods must be examined. This constructs the third part of the paper. As the final development of the paper, the above decomposition is utilised to define and determine driving point receptances required for dealing with wheel/rail interactions.

  11. Construction of tomographic head model using sectioned photographic images of cadaver

    International Nuclear Information System (INIS)

    Lee, Choon Sik; Lee, Jai Ki; Park, Jin Seo; Chung, Min Suk

    2004-01-01

    Tomographic models are currently the most complete, developed and realistic models of the human anatomy. They have been used to estimate organ doses for diagnostic radiation examination and radiotherapy treatment planning, and radiation protection. The quality of original anatomic images is a key factor to build a quality tomographic model. Computed tomography (CT) and magnetic resonance imaging (MRI) scan, from which most of current tomographic models are constructed, have their inherent shortcomings. In this study, a tomographic model of Korean adult male head was constructed by using serially sectioned photographs of cadaver. The cadaver was embedded, frozen, serially sectioned and photographed by high resolution digital camera at 0.2 mm interval. The contours of organs and tissues in photographs were segmented by several trained anatomists. The 120 segmented images of head at 2mm interval were converted into binary files and ported into Monte Carlo code to perform an example calculation of organ dose. Whole body tomographic model will be constructed by using the procedure developed in this study

  12. Modulation of horizontal cell receptive fields in the light adapted goldfish retina

    NARCIS (Netherlands)

    Verweij, J.; Kamermans, M.; van den Aker, E. C.; Spekreijse, H.

    1996-01-01

    In the isolated goldfish retina, 700 nm background illumination increases the horizontal cell receptive field size, as measured with 565 nm slits of light, but decreases the receptive field size, when measured with 660 nm slits. These background-induced changes in receptive field size are absent

  13. Investigation of the noise effect on tomographic reconstructions for a tangentially viewing vacuum ultraviolet imaging diagnostic

    International Nuclear Information System (INIS)

    Ming, Tingfeng; Ohdachi, Satoshi; Suzuki, Yasuhiro

    2011-01-01

    Tomographic reconstruction for a tangentially viewing two-dimensional (2D) imaging system is studied. A method to calculate the geometry matrix in 2D tomography is introduced. An algorithm based on a Phillips-Tikhonov (P-T) type regularization method is investigated, and numerical tests using the P-T method are conducted with both tokamak and Heliotron configurations. The numerical tests show that the P-T method is not sensitive to the added noise levels and the emission profiles with higher mode numbers can be reconstructed with adequate resolution. The results indicate that this method is suitable for 2D tomographic reconstruction for a tangentially viewing vacuum ultraviolet telescope system. (author)

  14. On a novel low cost high accuracy experimental setup for tomographic particle image velocimetry

    International Nuclear Information System (INIS)

    Discetti, Stefano; Ianiro, Andrea; Astarita, Tommaso; Cardone, Gennaro

    2013-01-01

    This work deals with the critical aspects related to cost reduction of a Tomo PIV setup and to the bias errors introduced in the velocity measurements by the coherent motion of the ghost particles. The proposed solution consists of using two independent imaging systems composed of three (or more) low speed single frame cameras, which can be up to ten times cheaper than double shutter cameras with the same image quality. Each imaging system is used to reconstruct a particle distribution in the same measurement region, relative to the first and the second exposure, respectively. The reconstructed volumes are then interrogated by cross-correlation in order to obtain the measured velocity field, as in the standard tomographic PIV implementation. Moreover, differently from tomographic PIV, the ghost particle distributions of the two exposures are uncorrelated, since their spatial distribution is camera orientation dependent. For this reason, the proposed solution promises more accurate results, without the bias effect of the coherent ghost particles motion. Guidelines for the implementation and the application of the present method are proposed. The performances are assessed with a parametric study on synthetic experiments. The proposed low cost system produces a much lower modulation with respect to an equivalent three-camera system. Furthermore, the potential accuracy improvement using the Motion Tracking Enhanced MART (Novara et al 2010 Meas. Sci. Technol. 21 035401) is much higher than in the case of the standard implementation of tomographic PIV. (paper)

  15. Terahertz Imaging for Biomedical Applications Pattern Recognition and Tomographic Reconstruction

    CERN Document Server

    Yin, Xiaoxia; Abbott, Derek

    2012-01-01

    Terahertz Imaging for Biomedical Applications: Pattern Recognition and Tomographic Reconstruction presents the necessary algorithms needed to assist screening, diagnosis, and treatment, and these algorithms will play a critical role in the accurate detection of abnormalities present in biomedical imaging. Terahertz biomedical imaging has become an area of interest due to its ability to simultaneously acquire both image and spectral information. Terahertz imaging systems are being commercialized with an increasing number of trials performed in a biomedical setting. Terahertz tomographic imaging and detection technology contributes to the ability to identify opaque objects with clear boundaries,and would be useful to both in vivo and ex vivo environments. This book also: Introduces terahertz radiation techniques and provides a number of topical examples of signal and image processing, as well as machine learning Presents the most recent developments in an emerging field, terahertz radiation Utilizes new methods...

  16. Receptivity of Hypersonic Boundary Layers to Acoustic and Vortical Disturbances (Invited)

    Science.gov (United States)

    Balakumar, P.

    2015-01-01

    Boundary-layer receptivity to two-dimensional acoustic and vortical disturbances for hypersonic flows over two-dimensional and axi-symmetric geometries were numerically investigated. The role of bluntness, wall cooling, and pressure gradients on the receptivity and stability were analyzed and compared with the sharp nose cases. It was found that for flows over sharp nose geometries in adiabatic wall conditions the instability waves are generated in the leading-edge region and that the boundary layer is much more receptive to slow acoustic waves as compared to the fast waves. The computations confirmed the stabilizing effect of nose bluntness and the role of the entropy layer in the delay of boundary layer transition. The receptivity coefficients in flows over blunt bodies are orders of magnitude smaller than that for the sharp cone cases. Wall cooling stabilizes the first mode strongly and destabilizes the second mode. However, the receptivity coefficients are also much smaller compared to the adiabatic case. The adverse pressure gradients increased the unstable second mode regions.

  17. Predicting Receptive-Expressive Vocabulary Discrepancies in Preschool Children With Autism Spectrum Disorder.

    Science.gov (United States)

    McDaniel, Jena; Yoder, Paul; Woynaroski, Tiffany; Watson, Linda R

    2018-05-15

    Correlates of receptive-expressive vocabulary size discrepancies may provide insights into why language development in children with autism spectrum disorder (ASD) deviates from typical language development and ultimately improve intervention outcomes. We indexed receptive-expressive vocabulary size discrepancies of 65 initially preverbal children with ASD (20-48 months) to a comparison sample from the MacArthur-Bates Communicative Development Inventories Wordbank (Frank, Braginsky, Yurovsky, & Marchman, 2017) to quantify typicality. We then tested whether attention toward a speaker and oral motor performance predict typicality of the discrepancy 8 months later. Attention toward a speaker correlated positively with receptive-expressive vocabulary size discrepancy typicality. Imitative and nonimitative oral motor performance were not significant predictors of vocabulary size discrepancy typicality. Secondary analyses indicated that midpoint receptive vocabulary size mediated the association between initial attention toward a speaker and end point receptive-expressive vocabulary size discrepancy typicality. Findings support the hypothesis that variation in attention toward a speaker might partially explain receptive-expressive vocabulary size discrepancy magnitude in children with ASD. Results are consistent with an input-processing deficit explanation of language impairment in this clinical population. Future studies should test whether attention toward a speaker is malleable and causally related to receptive-expressive discrepancies in children with ASD.

  18. Construction of a positron emission tomograph with 2.4 mm detectors

    International Nuclear Information System (INIS)

    McIntyre, J.A.; Sprosst, R.L.; Wang, K.

    1986-01-01

    One-quarter of one ring of a positron tomograph has been constructed. The positron annihilation gamma rays are detected by polished plastic scintillators which direct scintillation light by internal reflection to optical fibers for transmission to the photo-multiplier tubes. By viewing each scintillator with four sets of optical fibers, the number of photomultipliers required for an eight ring tomograph with 1024 detectors per ring (2.4 mm wide detectors) can be reduced from 8192 to 288, and the cost of the tomograph reduced accordingly

  19. An original acquisition chain for the TOHR High Resolution Tomograph

    International Nuclear Information System (INIS)

    Pinot, Laurent

    1999-01-01

    The framework of this work is part of a new approach of emission tomography adapted to small animals. The principle of our tomographic system TOHR (French acronym for High Resolution Tomograph) is based on the use of large solid angle and high resolution focusing collimators each mounted in front of a detection module of high efficiency. With a first-generation acquisition chain we were able to characterize TOHR, however, to take fully advantage of the TOHR possibilities, a completely new acquisition scheme had to be designed. This system, being the main topic of this work, makes use of temporal information. The detection of a particle that entered the detector is translated into temporal logical signals. These signals pass into a time coding circuitry and the coded results are transferred in a digital processor. According to the initial terms of delivery, the developed acquisition chain steers the detection of events dependent on the deposited energy and time of arrival. The latter is done by coincidence measurements. All elements are mounted on a special board included into a PC unit and a dedicated program controls the whole system. First experiments showed up the interest of the new acquisition unit for other application in physics or medical imaging

  20. Plasma radiation dynamics with the upgraded Absolute Extreme Ultraviolet tomographical system in the Tokamak à Configuration Variable

    Energy Technology Data Exchange (ETDEWEB)

    Tal, B.; Nagy, D.; Veres, G. [Institute for Particle and Nuclear Physics, Wigner Research Centre for Physics, Hungarian Academy of Sciences, Association EURATOM, P. O. Box 49, H-1525 Budapest (Hungary); Labit, B.; Chavan, R.; Duval, B. [Ecole Polytechnique Fédérale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas, Association EURATOM-Confédération Suisse, EPFL SB CRPP, Station 13, CH-1015 Lausanne (Switzerland)

    2013-12-15

    We introduce an upgraded version of a tomographical system which is built up from Absolute Extreme Ultraviolet-type (AXUV) detectors and has been installed on the Tokamak à Configuration Variable (TCV). The system is suitable for the investigation of fast radiative processes usually observed in magnetically confined high-temperature plasmas. The upgrade consists in the detector protection by movable shutters, some modifications to correct original design errors and the improvement in the data evaluation techniques. The short-term sensitivity degradation of the detectors, which is caused by the plasma radiation itself, has been monitored and found to be severe. The results provided by the system are consistent with the measurements obtained with the usual plasma radiation diagnostics installed on TCV. Additionally, the coupling between core plasma radiation and plasma-wall interaction is revealed. This was impossible with other available diagnostics on TCV.

  1. First-year university students’ receptive and productive use of academic vocabulary

    Directory of Open Access Journals (Sweden)

    Déogratias Nizonkiza

    2016-05-01

    Full Text Available The present study explores academic vocabulary knowledge, operationalised through the Academic Word List, among first-year higher education students. Both receptive and productive knowledge and the proportion between the two are examined. Results show that while receptive knowledge is readily acquired by first-year students, productive knowledge lags behind and remains problematic. This entails that receptive knowledge is much larger than productive knowledge, which confirms earlier indications that receptive vocabulary knowledge is larger than productive knowledge for both academic vocabulary (Zhou 2010 and general vocabulary (cf. Laufer 1998, Webb 2008, among others. Furthermore, results reveal that the ratio between receptive and productive knowledge is slightly above 50%, which lends empirical support to previous findings that the ratio between the two aspects of vocabulary knowledge can be anywhere between 50% and 80% (Milton 2009. This finding is extended here to academic vocabulary; complementing Zhou’s (2010 study that investigated the relationship between the two aspects of vocabulary knowledge without examining the ratio between them. On the basis of these results, approaches that could potentially contribute to fostering productive knowledge growth are discussed. Avenues worth exploring to gain further insight into the relationship between receptive and productive knowledge are also suggested.

  2. The Past in the Future: Problems and Potentials of Historical Reception Studies.

    Science.gov (United States)

    Jensen, Klaus Bruhn

    1993-01-01

    Gives examples of how qualitative methodologies have been employed to study media reception in the present. Identifies some forms of evidence that can creatively fill the gaps in knowledge about media reception in the past. Argues that the field must develop databases documenting media reception, which may broaden the scope of audience research in…

  3. Experience of computed tomographic myelography and discography in cervical problem

    Energy Technology Data Exchange (ETDEWEB)

    Nakatani, Shigeru; Yamamoto, Masayuki; Uratsuji, Masaaki; Suzuki, Kunio; Matsui, Eigo [Hyogo Prefectural Awaji Hospital, Sumoto, Hyogo (Japan); Kurihara, Akira

    1983-06-01

    CTM (computed tomographic myelography) was performed on 15 cases of cervical lesions, and on 5 of them, CTD (computed tomographic discography) was also made. CTM revealed the intervertebral state, and in combination with CTD, providing more accurate information. The combined method of CTM and CTD was useful for soft disc herniation.

  4. Tomographic findings of acute pulmonary toxoplasmosis in immunocompetent patients.

    Science.gov (United States)

    de Souza Giassi, Karina; Costa, Andre Nathan; Apanavicius, Andre; Teixeira, Fernando Bin; Fernandes, Caio Julio Cesar; Helito, Alfredo Salim; Kairalla, Ronaldo Adib

    2014-11-25

    Toxoplasmosis is one of the most common human zoonosis, and is generally benign in most of the individuals. Pulmonary involvement is common in immunocompromised subjects, but very rare in immunocompetents and there are scarce reports of tomographic findings in the literature. The aim of the study is to describe three immunocompetent patients diagnosed with acute pulmonary toxoplasmosis and their respective thoracic tomographic findings. Acute toxoplasmosis was diagnosed according to the results of serological tests suggestive of recent primary infection and the absence of an alternative etiology. From 2009 to 2013, three patients were diagnosed with acute respiratory failure secondary to acute toxoplasmosis. The patients were two female and one male, and were 38, 56 and 36 years old. Similarly they presented a two-week febrile illness and progressive dyspnea before admission. Laboratory tests demonstrated lymphocytosis, slight changes in liver enzymes and high inflammatory markers. Tomographic findings were bilateral smooth septal and peribronchovascular thickening (100%), ground-glass opacities (100%), atelectasis (33%), random nodules (33%), lymph node enlargement (33%) and pleural effusion (66%). All the patients improved their symptoms after treatment, and complete resolution of tomographic findings were found in the followup. These cases provide a unique description of the presentation and evolution of pulmonary tomographic manifestations of toxoplasmosis in immunocompetent patients. Toxoplasma pneumonia manifests with fever, dyspnea and a non-productive cough that may result in respiratory failure. In animal models, changes were described as interstitial pneumonitis with focal infiltrates of neutrophils that can finally evolve into a pattern of diffuse alveolar damage with focal necrosis. The tomographic findings are characterized as ground glass opacities, smooth septal and marked peribronchovascular thickening; and may mimic pulmonary congestion

  5. Construction of Korean male tomographic model segmented from PET-CT data

    International Nuclear Information System (INIS)

    Lee, Choon Sik; Park, Sang Kyun; Lee, Jai Ki

    2004-01-01

    Tomographic human models provide currently the most realistic representation of human anatomy for radiation dosimetry calculation. Most of the models have been constructed by using computed tomographic (CT) or magnetic resonance (MR) images obtained from a single individual. Each scan has its inherent advantages and disadvantages. CT scan gives a considerable radiation dose to a subject, and MR scan takes too long time to get clear images of an immobile subject. An emerging source of medical images for the construction of tomographic models is PET-CT, which is performed when looking for cancer. In this study, a tomographic model of Korean adult male was developed by processing whole-body CT images of a PET-CT-scanned healthy volunteer. The 343 slices of the CT images were semi-automatically segmented layer by layer using a graphic software and screen digitizer. The 3rd Korean tomographic model, named KRMAN-2, consisting of 300x150x344 voxels of a size of 2x2x5mm 3 , was constructed. Examples of application to Monte Carlo radiation dosimetry calculation in idealized whole-body irradiations were given and discussed

  6. A Penalization Approach for Tomographic Reconstruction of Binary Axially Symmetric Objects

    International Nuclear Information System (INIS)

    Abraham, R.; Bergounioux, M.; Trelat, E.

    2008-01-01

    We propose a variational method for tomographic reconstruction of blurred and noised binary images based on a penalization process of a minimization problem settled in the space of bounded variation functions. We prove existence and/or uniqueness results and derive a penalized optimality system. Numerical simulations are provided to demonstrate the relevance of the approach

  7. Development of x-ray computed tomographic scanner for iron and steel

    International Nuclear Information System (INIS)

    Taguchi, Isamu; Nakamura, Shigeo.

    1985-01-01

    X-ray computed tomography is extensively used in medicine, but has rarely been applied to non-medical purposes. Steel specimens pose particularly difficult problems-very poor transmission of X-rays and the need for high resolving capability. There has thus been no effective tomographic method of examining steel specimens. Due to the growing need for non-destructive, non-contact methods for observing and analyzing the internal conditions of steel microscopically, however, we have developed an X-ray Computed Tomographic Scanner for Steel (CTS) system, specifically for examination of steel specimens. Its major specifications and functions are as follows. Type: the second-generation CT, 8-channels, Scanning method: 6 0 revolution, 30-times traversing, Slice width: 0.5 mm, Resolving capability: 0.25 x 0.25 mm, X-ray source: 420 kV, 3 mA, X-ray detector: BGO scintillator, Standard specimen shape: 50 mm dia., 100 mm high, Measuring time: 10.5 min. Porosity of a stainless steel (SUS 304) bloom was examined three-dimensionally by the CTS system. Corrosion procedure of a steel slab was also examined. (author)

  8. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Huber, Jennifer

    2004-01-01

    The goal of this project is to construct a functioning compact positron tomograph, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  9. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Huber, Jennifer S

    2005-01-01

    The goal of this project is to construct a functioning compact positron tomograph, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  10. Diagnostic accuracy of multi-slice computed tomographic angiography in the detection of cerebral aneurysms

    International Nuclear Information System (INIS)

    Haghighatkhah, H. R.; Sabouri, S.; Borzouyeh, F.; Bagherzadeh, M. H.; Bakhshandeh, H.; Jalali, A. H.

    2008-01-01

    Multislice computed tomographic angiography is a rapid and minimally invasive method for the detection of intracranial aneurysms. The purpose of this study was to compare Multislice computed tomographic angiography with digital subtraction angiography In the diagnosis of cerebral aneurysms. Patients and Methods: In this cross sectional study we evaluated 111 consecutive patients [42(37.8%) male and 69(62.2%) female], who were admitted under clinical symptoms and signs. suggestive of harboring an intracranial aneurysm by using a four detector Multislice computed tomographic angiography. Then we compared results of Multislice computed tomographic angiography with digital subtraction angiography results as a gold standard method. Digital subtraction angiography was performed by bilateral selective common carotid artery injections and either unilateral or bilateral vertebral artery injections, as necessary. Multislice computed tomographic angiography images were interpreted by one radiologist and digital subtraction angiography was performed by another radiologist who was blinded to the interpretation of the Multislice computed tomographic angiograms. Results: The mean ±S D age of the patients was 49.1±13.6 years (range: 12-84 years). We performed Multislice computed tomographic in 111 and digital subtraction angiography in 85 patients. The sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratio of Multislice computed tomographic angiography, when compared with digital subtraction angiography as the gold standard, were 100%, 90%, 87.5%, 100%, 10 and 0, respectively. Conclusion: Multislice computed tomographic angiography seems to be an accurate and noninvasive imaging modality in the diagnosis of intracranial aneurysms

  11. A self-organizing model of perisaccadic visual receptive field dynamics in primate visual and oculomotor system.

    Science.gov (United States)

    Mender, Bedeho M W; Stringer, Simon M

    2015-01-01

    We propose and examine a model for how perisaccadic visual receptive field dynamics, observed in a range of primate brain areas such as LIP, FEF, SC, V3, V3A, V2, and V1, may develop through a biologically plausible process of unsupervised visually guided learning. These dynamics are associated with remapping, which is the phenomenon where receptive fields anticipate the consequences of saccadic eye movements. We find that a neural network model using a local associative synaptic learning rule, when exposed to visual scenes in conjunction with saccades, can account for a range of associated phenomena. In particular, our model demonstrates predictive and pre-saccadic remapping, responsiveness shifts around the time of saccades, and remapping from multiple directions.

  12. What is so ‘classical’ about Classical Reception? Theories, Methodologies and Future Prospects

    OpenAIRE

    Anastasia Bakogianni

    2016-01-01

    This paper delivered at the University of Rio on 3rd June 2015 seeks to explore different approaches to the most fundamental questions in classical reception studies. What is classical reception? And more particularly what is so ‘classical’ about classical reception? It discusses current trends in theory and methodology via an analysis of two cinematic receptions of the ancient story of Electra; one that proclaims its debt to a classical text while the other masks its classical connections.

  13. Attention operates uniformly throughout the classical receptive field and the surround

    Science.gov (United States)

    Verhoef, Bram-Ernst; Maunsell, John HR

    2016-01-01

    Shifting attention among visual stimuli at different locations modulates neuronal responses in heterogeneous ways, depending on where those stimuli lie within the receptive fields of neurons. Yet how attention interacts with the receptive-field structure of cortical neurons remains unclear. We measured neuronal responses in area V4 while monkeys shifted their attention among stimuli placed in different locations within and around neuronal receptive fields. We found that attention interacts uniformly with the spatially-varying excitation and suppression associated with the receptive field. This interaction explained the large variability in attention modulation across neurons, and a non-additive relationship among stimulus selectivity, stimulus-induced suppression and attention modulation that has not been previously described. A spatially-tuned normalization model precisely accounted for all observed attention modulations and for the spatial summation properties of neurons. These results provide a unified account of spatial summation and attention-related modulation across both the classical receptive field and the surround. DOI: http://dx.doi.org/10.7554/eLife.17256.001 PMID:27547989

  14. Nonlinear Hebbian Learning as a Unifying Principle in Receptive Field Formation.

    Science.gov (United States)

    Brito, Carlos S N; Gerstner, Wulfram

    2016-09-01

    The development of sensory receptive fields has been modeled in the past by a variety of models including normative models such as sparse coding or independent component analysis and bottom-up models such as spike-timing dependent plasticity or the Bienenstock-Cooper-Munro model of synaptic plasticity. Here we show that the above variety of approaches can all be unified into a single common principle, namely nonlinear Hebbian learning. When nonlinear Hebbian learning is applied to natural images, receptive field shapes were strongly constrained by the input statistics and preprocessing, but exhibited only modest variation across different choices of nonlinearities in neuron models or synaptic plasticity rules. Neither overcompleteness nor sparse network activity are necessary for the development of localized receptive fields. The analysis of alternative sensory modalities such as auditory models or V2 development lead to the same conclusions. In all examples, receptive fields can be predicted a priori by reformulating an abstract model as nonlinear Hebbian learning. Thus nonlinear Hebbian learning and natural statistics can account for many aspects of receptive field formation across models and sensory modalities.

  15. What is so ‘classical’ about Classical Reception? Theories, Methodologies and Future Prospects

    Directory of Open Access Journals (Sweden)

    Anastasia Bakogianni

    2016-06-01

    Full Text Available This paper delivered at the University of Rio on 3rd June 2015 seeks to explore different approaches to the most fundamental questions in classical reception studies. What is classical reception? And more particularly what is so ‘classical’ about classical reception? It discusses current trends in theory and methodology via an analysis of two cinematic receptions of the ancient story of Electra; one that proclaims its debt to a classical text while the other masks its classical connections.

  16. Preparation and tomographic reconstruction of an arbitrary single-photon path qubit

    International Nuclear Information System (INIS)

    Baek, So-Young; Kim, Yoon-Ho

    2011-01-01

    We report methods for preparation and tomographic reconstruction of an arbitrary single-photon path qubit. The arbitrary single-photon path qubit is prepared losslessly by passing the heralded single-photon state from spontaneous parametric down-conversion through variable beam splitter. Quantum state tomography of the single-photon path qubit is implemented by introducing path-projection measurements based on the first-order single-photon quantum interference. Using the state preparation and path-projection measurements methods for the single-photon path qubit, we demonstrate preparation and complete tomographic reconstruction of the single-photon path qubit with arbitrary purity. -- Highlights: → We report methods for preparation and tomographic reconstruction of an arbitrary single-photon path qubit. → We implement path-projection measurements based on the first-order single-photon quantum interference. → We demonstrate preparation and complete tomographic reconstruction of the single-photon path qubit with arbitrary purity.

  17. Advertising Receptivity and Youth Initiation of Smokeless Tobacco.

    Science.gov (United States)

    Timberlake, David S

    2016-07-28

    Cross-sectional data suggests that adolescents' receptivity to the advertising of smokeless tobacco is correlated with use of chewing tobacco or snuff. Lack of longitudinal data has precluded determination of whether advertising receptivity precedes or follows initiation of smokeless tobacco. The objective of this study was to test for the association between advertising receptivity and subsequent initiation of smokeless tobacco among adolescent males. Adolescent males from the 1993-1999 Teen Longitudinal California Tobacco Survey were selected at the baseline survey for never having used smokeless tobacco. Separate longitudinal analyses corresponded to two dependent variables, ever use of smokeless tobacco (1993-1996; N = 1,388) and use on 20 or more occasions (1993-1999; N = 1,014). Models were adjusted for demographic variables, risk factors for smokeless tobacco use, and exposure to users of smokeless tobacco. Advertising receptivity at baseline was predictive of ever use by late adolescence (RR(95% CI) = 2.0 (1.5, 2.8)) and regular use by young adulthood (RR(95% CI) = 3.7 (2.1, 6.7)) in models that were adjusted for covariates. Conclusions/ Importance: The findings challenge the tobacco industry's assertion that tobacco marketing does not impact youth initiation. This is particularly relevant to tobacco control in the United States because the 2009 Tobacco Control Act places fewer restrictions on smokeless tobacco products compared to cigarettes.

  18. Cortico-Cortical Receptive Field Estimates in Human Visual Cortex

    Directory of Open Access Journals (Sweden)

    Koen V Haak

    2012-05-01

    Full Text Available Human visual cortex comprises many visual areas that contain a map of the visual field (Wandell et al 2007, Neuron 56, 366–383. These visual field maps can be identified readily in individual subjects with functional magnetic resonance imaging (fMRI during experimental sessions that last less than an hour (Wandell and Winawer 2011, Vis Res 718–737. Hence, visual field mapping with fMRI has been, and still is, a heavily used technique to examine the organisation of both normal and abnormal human visual cortex (Haak et al 2011, ACNR, 11(3, 20–21. However, visual field mapping cannot reveal every aspect of human visual cortex organisation. For example, the information processed within a visual field map arrives from somewhere and is sent to somewhere, and visual field mapping does not derive these input/output relationships. Here, we describe a new, model-based analysis for estimating the dependence between signals in distinct cortical regions using functional magnetic resonance imaging (fMRI data. Just as a stimulus-referred receptive field predicts the neural response as a function of the stimulus contrast, the neural-referred receptive field predicts the neural response as a function of responses elsewhere in the nervous system. When applied to two cortical regions, this function can be called the cortico-cortical receptive field (CCRF. We model the CCRF as a Gaussian-weighted region on the cortical surface and apply the model to data from both stimulus-driven and resting-state experimental conditions in visual cortex.

  19. Longitudinal analysis of receptive vocabulary growth in young Spanish English-speaking children from migrant families.

    Science.gov (United States)

    Jackson, Carla Wood; Schatschneider, Christopher; Leacox, Lindsey

    2014-01-01

    The authors of this study described developmental trajectories and predicted kindergarten performance of Spanish and English receptive vocabulary acquisition of young Latino/a English language learners (ELLs) from socioeconomically disadvantaged migrant families. In addition, the authors examined the extent to which gender and individual initial performance in Spanish predict receptive vocabulary performance and growth rate. The authors used hierarchical linear modeling of 64 children's receptive vocabulary performance to generate growth trajectories, predict performance at school entry, and examine potential predictors of rate of growth. The timing of testing varied across children. The ELLs (prekindergarten to 2nd grade) participated in 2-5 testing sessions, each 6-12 months apart. The ELLs' average predicted standard score on an English receptive vocabulary at kindergarten was nearly 2 SDs below the mean for monolingual peers. Significant growth in the ELLs' receptive vocabulary was observed between preschool and 2nd grade, indicating that the ELLs were slowly closing the receptive vocabulary gap, although their average score remained below the standard score mean for age-matched monolingual peers. The ELLs demonstrated a significant decrease in Spanish receptive vocabulary standard scores over time. Initial Spanish receptive vocabulary was a significant predictor of growth in English receptive vocabulary. High initial Spanish receptive vocabulary was associated with greater growth in English receptive vocabulary and decelerated growth in Spanish receptive vocabulary. Gender was not a significant predictor of growth in either English or Spanish receptive vocabulary. ELLs from low socioeconomic backgrounds may be expected to perform lower in English compared with their monolingual English peers in kindergarten. Performance in Spanish at school entry may be useful in identifying children who require more intensive instructional support for English vocabulary

  20. Computed tomographic findings of intracranial gliosis

    International Nuclear Information System (INIS)

    Weisberg, L.

    1981-01-01

    The clinical and computed tomographic (CT) findings in eight patients with pathological evidence of cerebral gliosis are analyzed. CT findings do not permit differentiation of gliosis from other neoplastic and non-neoplastic conditions. (orig.)

  1. An original acquisition chain for the TOHR High Resolution Tomograph[OASIS]; Conception d'une chaine d'acqusition originale pour le Tomographe Haute Resolution TOHR

    Energy Technology Data Exchange (ETDEWEB)

    Pinot, Laurent [Institut de Physique Nucleaire, Paris-11 Univ., 91 - Orsay (France)

    1999-04-02

    The framework of this work is part of a new approach of emission tomography adapted to small animals. The principle of our tomographic system TOHR (French acronym for High Resolution Tomograph) is based on the use of large solid angle and high resolution focusing collimators each mounted in front of a detection module of high efficiency. With a first-generation acquisition chain we were able to characterize TOHR, however, to take fully advantage of the TOHR possibilities, a completely new acquisition scheme had to be designed. This system, being the main topic of this work, makes use of temporal information. The detection of a particle that entered the detector is translated into temporal logical signals. These signals pass into a time coding circuitry and the coded results are transferred in a digital processor. According to the initial terms of delivery, the developed acquisition chain steers the detection of events dependent on the deposited energy and time of arrival. The latter is done by coincidence measurements. All elements are mounted on a special board included into a PC unit and a dedicated program controls the whole system. First experiments showed up the interest of the new acquisition unit for other application in physics or medical imaging.

  2. Collimated trans-axial tomographic scintillation camera

    International Nuclear Information System (INIS)

    1980-01-01

    The objects of this invention are first to reduce the time required to obtain statistically significant data in trans-axial tomographic radioisotope scanning using a scintillation camera. Secondly, to provide a scintillation camera system to increase the rate of acceptance of radioactive events to contribute to the positional information obtainable from a known radiation source without sacrificing spatial resolution. Thirdly to reduce the scanning time without loss of image clarity. The system described comprises a scintillation camera detector, means for moving this in orbit about a cranial-caudal axis relative to a patient and a collimator having septa defining apertures such that gamma rays perpendicular to the axis are admitted with high spatial resolution, parallel to the axis with low resolution. The septa may be made of strips of lead. Detailed descriptions are given. (U.K.)

  3. Population receptive field (pRF) measurements of chromatic responses in human visual cortex using fMRI.

    Science.gov (United States)

    Welbourne, Lauren E; Morland, Antony B; Wade, Alex R

    2018-02-15

    The spatial sensitivity of the human visual system depends on stimulus color: achromatic gratings can be resolved at relatively high spatial frequencies while sensitivity to isoluminant color contrast tends to be more low-pass. Models of early spatial vision often assume that the receptive field size of pattern-sensitive neurons is correlated with their spatial frequency sensitivity - larger receptive fields are typically associated with lower optimal spatial frequency. A strong prediction of this model is that neurons coding isoluminant chromatic patterns should have, on average, a larger receptive field size than neurons sensitive to achromatic patterns. Here, we test this assumption using functional magnetic resonance imaging (fMRI). We show that while spatial frequency sensitivity depends on chromaticity in the manner predicted by behavioral measurements, population receptive field (pRF) size measurements show no such dependency. At any given eccentricity, the mean pRF size for neuronal populations driven by luminance, opponent red/green and S-cone isolating contrast, are identical. Changes in pRF size (for example, an increase with eccentricity and visual area hierarchy) are also identical across the three chromatic conditions. These results suggest that fMRI measurements of receptive field size and spatial resolution can be decoupled under some circumstances - potentially reflecting a fundamental dissociation between these parameters at the level of neuronal populations. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  4. High resolution tomographic instrument development

    International Nuclear Information System (INIS)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational

  5. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  6. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  7. Sparse coding can predict primary visual cortex receptive field changes induced by abnormal visual input.

    Science.gov (United States)

    Hunt, Jonathan J; Dayan, Peter; Goodhill, Geoffrey J

    2013-01-01

    Receptive fields acquired through unsupervised learning of sparse representations of natural scenes have similar properties to primary visual cortex (V1) simple cell receptive fields. However, what drives in vivo development of receptive fields remains controversial. The strongest evidence for the importance of sensory experience in visual development comes from receptive field changes in animals reared with abnormal visual input. However, most sparse coding accounts have considered only normal visual input and the development of monocular receptive fields. Here, we applied three sparse coding models to binocular receptive field development across six abnormal rearing conditions. In every condition, the changes in receptive field properties previously observed experimentally were matched to a similar and highly faithful degree by all the models, suggesting that early sensory development can indeed be understood in terms of an impetus towards sparsity. As previously predicted in the literature, we found that asymmetries in inter-ocular correlation across orientations lead to orientation-specific binocular receptive fields. Finally we used our models to design a novel stimulus that, if present during rearing, is predicted by the sparsity principle to lead robustly to radically abnormal receptive fields.

  8. Original circuitry for TOHR tomograph

    International Nuclear Information System (INIS)

    Cuzon, J.C.; Pinot, L.

    1999-01-01

    Having industrialization in mind, a specific electronics for a high resolution tomograph is designed out of the usual standards of nuclear physics. All the information are converted in the time domain and a fast processor, in front of the data acquisition, carries out the time and energy coincidences. (authors)

  9. Receptive fields selection for binary feature description.

    Science.gov (United States)

    Fan, Bin; Kong, Qingqun; Trzcinski, Tomasz; Wang, Zhiheng; Pan, Chunhong; Fua, Pascal

    2014-06-01

    Feature description for local image patch is widely used in computer vision. While the conventional way to design local descriptor is based on expert experience and knowledge, learning-based methods for designing local descriptor become more and more popular because of their good performance and data-driven property. This paper proposes a novel data-driven method for designing binary feature descriptor, which we call receptive fields descriptor (RFD). Technically, RFD is constructed by thresholding responses of a set of receptive fields, which are selected from a large number of candidates according to their distinctiveness and correlations in a greedy way. Using two different kinds of receptive fields (namely rectangular pooling area and Gaussian pooling area) for selection, we obtain two binary descriptors RFDR and RFDG .accordingly. Image matching experiments on the well-known patch data set and Oxford data set demonstrate that RFD significantly outperforms the state-of-the-art binary descriptors, and is comparable with the best float-valued descriptors at a fraction of processing time. Finally, experiments on object recognition tasks confirm that both RFDR and RFDG successfully bridge the performance gap between binary descriptors and their floating-point competitors.

  10. Promoting the Aesthetic Experience: The Rise of Receptive Art Education in the Netherlands

    NARCIS (Netherlands)

    Dieleman, C.

    2014-01-01

    In 1999, a mandatory and interdisciplinary art course, Cultural and Artistic Education (Culturele en Kunstzinnige Vorming, or CKV), was introduced in the Dutch secondary school system. The course focuses on receptive, rather than active, art education. Cultural activities, such as visiting an art

  11. Problems of generation and reception of gravitational waves

    International Nuclear Information System (INIS)

    Pisarev, A.F.

    1975-01-01

    The present day status of the problems of gravitation, wave radiation and reception is surveyed. The physical presentation and mathematical description of the processes of radiation, propagation and interaction of gravitation waves with matter and the electromagnetic field are given. The experiments on the search for gravitation waves of astophysical nature are analysed. The laboratory and cosmic sources of these waves and the methods of their reception are described. Special attention is drawn to the analysis of the proposals to perform a complete laboratory gravitation wave experiment

  12. Nonlinear Hebbian Learning as a Unifying Principle in Receptive Field Formation.

    Directory of Open Access Journals (Sweden)

    Carlos S N Brito

    2016-09-01

    Full Text Available The development of sensory receptive fields has been modeled in the past by a variety of models including normative models such as sparse coding or independent component analysis and bottom-up models such as spike-timing dependent plasticity or the Bienenstock-Cooper-Munro model of synaptic plasticity. Here we show that the above variety of approaches can all be unified into a single common principle, namely nonlinear Hebbian learning. When nonlinear Hebbian learning is applied to natural images, receptive field shapes were strongly constrained by the input statistics and preprocessing, but exhibited only modest variation across different choices of nonlinearities in neuron models or synaptic plasticity rules. Neither overcompleteness nor sparse network activity are necessary for the development of localized receptive fields. The analysis of alternative sensory modalities such as auditory models or V2 development lead to the same conclusions. In all examples, receptive fields can be predicted a priori by reformulating an abstract model as nonlinear Hebbian learning. Thus nonlinear Hebbian learning and natural statistics can account for many aspects of receptive field formation across models and sensory modalities.

  13. Design of a volume-imaging positron emission tomograph

    International Nuclear Information System (INIS)

    Harrop, R.; Rogers, J.G.; Coombes, G.H.; Wilkinson, N.A.; Pate, B.D.; Morrison, K.S.; Stazyk, M.; Dykstra, C.J.; Barney, J.S.; Atkins, M.S.; Doherty, P.W.; Saylor, D.P.

    1988-11-01

    Progress is reported in several areas of design of a positron volume imaging tomograph. As a means of increasing the volume imaged and the detector packing fraction, a lens system of detector light coupling is considered. A prototype layered scintillator detector demonstrates improved spatial resolution due to a unique Compton rejection capability. The conceptual design of a new mechanism for measuring scattered radiation during emission scans has been tested by Monte Carlo simulation. The problem of how to use effectively the resulting sampled scattered radiation projections is presented and discussed

  14. The Foucault-Habermas Debate: the Reflexive and Receptive Aspects of Critique

    DEFF Research Database (Denmark)

    Hansen, Ejvind

    2005-01-01

    In this paper I discuss the relationship between two different approaches to critical theory – the reflective and the receptive approaches. I show how it can be fruitful to discuss the relationship between Habermas and Foucault through this distinction. My point is that whereas Habermas focusses...... on critique as a reflexive activity, Foucault mainly focusses on the receptive conditions for critique to be possible. I argue further that Foucault focusses on the receptive aspects of critique, the quest for universality is not as pressing as it is in Habermas’ approach, because problematizing critique can...

  15. Correction of ring artifacts in X-ray tomographic images

    DEFF Research Database (Denmark)

    Lyckegaard, Allan; Johnson, G.; Tafforeau, P.

    2011-01-01

    Ring artifacts are systematic intensity distortions located on concentric circles in reconstructed tomographic X-ray images. When using X-ray tomography to study for instance low-contrast grain boundaries in metals it is crucial to correct for the ring artifacts in the images as they may have...... the same intensity level as the grain boundaries and thus make it impossible to perform grain segmentation. This paper describes an implementation of a method for correcting the ring artifacts in tomographic X-ray images of simple objects such as metal samples where the object and the background...... are separable. The method is implemented in Matlab, it works with very little user interaction and may run in parallel on a cluster if applied to a whole stack of images. The strength and robustness of the method implemented will be demonstrated on three tomographic X-ray data sets: a mono-phase β...

  16. Deaf Students' Receptive and Expressive American Sign Language Skills: Comparisons and Relations

    Science.gov (United States)

    Beal-Alvarez, Jennifer S.

    2014-01-01

    This article presents receptive and expressive American Sign Language skills of 85 students, 6 through 22 years of age at a residential school for the deaf using the American Sign Language Receptive Skills Test and the Ozcaliskan Motion Stimuli. Results are presented by ages and indicate that students' receptive skills increased with age and…

  17. The Receptive Side of Teaching

    Science.gov (United States)

    Hruska, Barbara

    2008-01-01

    When observing teachers in action, one is likely to witness explaining, modeling, managing, guiding, and encouraging. These expressive behaviors constitute a directive force moving outward from teacher to students. Though less visible to an outside observer, teaching also requires receptive skills, the ability to take in information by being fully…

  18. [Introducing computer units into the reception office as part of the Vrapce Psychiatric Hospital Information System].

    Science.gov (United States)

    Majdancić, Zeljko; Jukić, Vlado; Bojić, Miroslav

    2005-01-01

    Computerized medical record has become a necessity today, because of both the amount of present-day medical data and the need of better handling and processing them. In more than 120 years of the Vrapce Psychiatric Hospital existence, the most important changes in the working concept of the reception office took place when computer technology was introduced into the routine use. The reception office of the Hospital is the vital place where administrative activities intersect with medical care for a patient presenting to the Hospital. The importance of this segment of the Hospital is emphasized by the fact that the reception office is in function and at patients' disposition round-the-clock, for 365 days a year, with great frequency of patients. The shift from the established way of registering medical data on patient admission in handwriting or, later, typescript, to computer recording was a challenging and demanding task (from the aspects of hardware, software, network, education) for the development team as well as for the physicians because it has changed the concept (logic of the working process) of previous way of collecting the data from the patient (history, status, diagnostic procedures, therapy, etc.). The success in the development and implementation of this project and the confirmation of its usefulness during the four-year practice at Vrapce Psychiatric Hospital are best illustrated by the fact that other psychiatric hospitals in Croatia have already introduced or are introducing it in their daily practice.

  19. Developmental Stages in Receptive Grammar Acquisition: A Processability Theory Account

    Science.gov (United States)

    Buyl, Aafke; Housen, Alex

    2015-01-01

    This study takes a new look at the topic of developmental stages in the second language (L2) acquisition of morphosyntax by analysing receptive learner data, a language mode that has hitherto received very little attention within this strand of research (for a recent and rare study, see Spinner, 2013). Looking at both the receptive and productive…

  20. Gas microstrip detectors for X-ray tomographic flow imaging

    CERN Document Server

    Key, M J; Luggar, R D; Kundu, A

    2003-01-01

    A investigation into the suitability of gas microstrip detector technology for a high-speed industrial X-ray tomography system is reported. X-ray energies in the region 20-30 keV are well suited to the application, which involves imaging two-dimensional slices through gas/liquid multiphase pipeline flows for quantitative component fraction measurement. Stable operation over a period representing several hundred individual tomographic scans at gas gains of 500 is demonstrated using a Penning gas mixture of krypton/propylene.

  1. Tomographic apparatus and method for reconstructing planar slices from non-absorbed and non-scattered radiation

    International Nuclear Information System (INIS)

    1980-01-01

    An apparatus is described which can be used in computerized tomographic systems for constructing a representation of an object and which uses a fan-shaped beam source, detectors and a convolution method of data reconstruction. (U.K.)

  2. Regulation regarding the reception of the construction works and the corresponding installations in Romania

    Directory of Open Access Journals (Sweden)

    Simona Chirică

    2017-12-01

    Full Text Available The new Regulation regarding the reception of construction works and corresponding installations, approved by Government's Decision no. 347/2017 (“Regulation 2017” has general applicability for all construction works for which there is an obligation to obtain a building permit. Regulation 2017 brings significant changes and clarifications expected by the real estate sector regarding: (i the composition of the commissions involved in the reception procedure, (ii the role of the site supervisor who thus gains significant participation in the reception procedure, and (iii the participation of the public authorities' representatives at the reception, having the veto right on the decision of the reception commission upon the completion of the construction works. Another element of novelty brought by Regulation 2017 is the possibility to do the reception upon the completion of the construction works, respectively the final reception for parts / objectives / sectors of or from the building, if they are distinct/ independent from a physical and functional point of view. Thus, the new regulation facilitates the procedure of authorizing investment objectives and the costs of the process. The partial reception is another innovation brought by the Regulation 2017 in support of the investor, who can thus take over a part of the construction, at a certain stage, and obtain its registration with the Land Book.

  3. Communication from Goods Reception services

    CERN Multimedia

    2007-01-01

    Members of the personnel are invited to take note that only parcels corresponding to official orders or contracts will be handled at CERN. Individuals are not authorised to have private merchandise delivered to them at CERN and private deliveries will not be accepted by the Goods Reception services. Thank you for your understanding.

  4. Tomographic findings of lobar consolidation in primary pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Pereira, Bruno Alberto Falcao; Macedo, Solange Goncalves David de; Penna, Claudia Renata Rezende

    2009-01-01

    Objective: To describe tomographic findings of lobar consolidation as early manifestation of primary pulmonary tuberculosis. Materials and methods: The present study was developed at Hospital Municipal Jesus, Rio de Janeiro, RJ, Brazil, in the period between 2002 and 2006, retrospectively evaluating tomographic findings in four children aged from 3 to 14 months with lobar consolidation as an early manifestation of primary pulmonary tuberculosis. Results: The most frequently found radiological pattern was lobar consolidation with calcifications, cavitation and intermingle necrotic areas, associated with bulging fissure. Signs of bronchogenic dissemination and lymph node enlargement were observed in all of the four children. Consolidation with a pseudotumor aspect and masslike effect was observed in one case. Conclusion: The cases included in the present study have demonstrated that primary pulmonary tuberculosis manifested as lobar consolidation presents typical tomographic images such as cavitation, hypodense areas and calcifications intermingled with consolidation. The association with lymph node enlargement with central necrosis and signs of bronchogenic dissemination reinforce the diagnosis of tuberculosis. (author)

  5. The receptive-expressive gap in the vocabulary of young second-language learners: Robustness and possible mechanisms

    OpenAIRE

    Gibson, Todd A.; Oller, D. Kimbrough; Jarmulowicz, Linda; Ethington, Corinna A.

    2012-01-01

    Adults and children learning a second language show difficulty accessing expressive vocabulary that appears accessible receptively in their first language (L1). We call this discrepancy the receptive-expressive gap. Kindergarten Spanish (L1) - English (L2) sequential bilinguals were given standardized tests of receptive and expressive vocabulary in both Spanish and English. We found a small receptive-expressive gap in English but a large receptive-expressive gap in Spanish. We categorized chi...

  6. Design of the first optical system for real-time tomographic holography (RTTH)

    Science.gov (United States)

    Galeotti, John M.; Siegel, Mel; Rallison, Richard D.; Stetten, George

    2008-08-01

    The design of the first Real-Time-Tomographic-Holography (RTTH) optical system for augmented-reality applications is presented. RTTH places a viewpoint-independent real-time (RT) virtual image (VI) of an object into its actual location, enabling natural hand-eye coordination to guide invasive procedures, without requiring tracking or a head-mounted device. The VI is viewed through a narrow-band Holographic Optical Element (HOE) with built-in power that generates the largest possible near-field, in-situ VI from a small display chip without noticeable parallax error or obscuring direct view of the physical world. Rigidly fixed upon a medical-ultrasound probe, RTTH could show the scan in its actual location inside the patient, because the VI would move with the probe. We designed the image source along with the system-optics, allowing us to ignore both planer geometric distortions and field curvature, respectively compensated by using RT pre-processing software and attaching a custom-surfaced fiber-optic-faceplate (FOFP) to our image source. Focus in our fast, non-axial system was achieved by placing correcting lenses near the FOFP and custom-optically-fabricating our volume-phase HOE using a recording beam that was specially shaped by extra lenses. By simultaneously simulating and optimizing the system's playback performance across variations in both the total playback and HOE-recording optical systems, we derived and built a design that projects a 104x112 mm planar VI 1 m from the HOE using a laser-illuminated 19x16 mm LCD+FOFP image-source. The VI appeared fixed in space and well focused. Viewpoint-induced location errors were <3 mm, and unexpected first-order astigmatism produced 3 cm (3% of 1 m) ambiguity in depth, typically unnoticed by human observers.

  7. Geographic information system data from ambulances applied in the emergency department: effects on patient reception.

    Science.gov (United States)

    Raaber, Nikolaj; Duvald, Iben; Riddervold, Ingunn; Christensen, Erika F; Kirkegaard, Hans

    2016-03-31

    Emergency departments (ED) recognize crowding and handover from prehospital to in-hospital settings to be major challenges. Prehospital Geographical Information Systems (GIS) may be a promising tool to address such issues. In this study, the use of prehospital GIS data was implemented in an ED in order to investigate its effect on 1) wait time and unprepared activations of Trauma Teams (TT) and Medical Emergency Teams (MET) and 2) nurses' perceptions regarding patient reception, workflow and resource utilization. From May 1st 2014 to October 31th 2014, GIS data was displayed in the ED. Data included real-time estimated time of arrival, distance to ED, dispatch criteria, patient data and ambulance contact information. Data was used by coordinating nurses for time activation of TT and MET involved in the initial treatment of severely-injured or critically-ill patients. In addition, it was used as a logistics tool for handling all other patients transported by ambulance to the ED. The study followed a mixed-methods design, consisting of a quantitative study (before and after intervention) and a qualitative study (survey and interviews). Participants included all patients received by TT or MET and coordinating nurses in the ED. 1.) Quantitative: 599 patients were included. The median wait time for TT and MET was 5 min both before and after the GIS intervention, showing no difference (p = 0.18). A significant reduction in the subgroup of waits >10 min was found (p GIS data as a tool to optimize resource utilization and quality of all patients' reception, critically or non-critically ill. No substantial disadvantages were reported. The contradiction of measured median wait time and nurses perceived improved timing of team activation may result from having both RT- ETA and supplemental patient information not only for seriously-injured or critically-ill patients received by the TT and MET, but for all patients transported by ambulance. The reduction in waits > 10

  8. Tomographic images of cerebral blood flow using a slant hole collimator

    International Nuclear Information System (INIS)

    Wraight, E.P.; Barber, R.W.; Crossland, P.; Maltby, P.

    1983-01-01

    The feasibility of using a rotating slant hole (RSH) collimator on simple tomographic equipment such as a standard gamma camera interfaced to a general purpose Nuclear Medicine computer is reported for producing images of cerebral blood flow following the administration of 123 I-iodoamphetamine to patients. Initial studies produced satisfactory images, thus opening the possibility of tomographic cerebral blood flow imaging to centres not possessing sophisticated tomographic equipment. Planar resolution is superior to that reported for a 25 0 RSH collimator. Axial resolution is not as good at small source distances but is comparable at distances beyond 10 cm. Sensitivity is comparable to other RSH collimators and is similar to Technicare's parallel hole general all purpose collimator. (UK)

  9. Pipelining Computational Stages of the Tomographic Reconstructor for Multi-Object Adaptive Optics on a Multi-GPU System

    KAUST Repository

    Charara, Ali; Ltaief, Hatem; Gratadour, Damien; Keyes, David E.; Sevin, Arnaud; Abdelfattah, Ahmad; Gendron, Eric; Morel, Carine; Vidal, Fabrice

    2014-01-01

    called MOSAIC has been proposed to perform multi-object spectroscopy using the Multi-Object Adaptive Optics (MOAO) technique. The core implementation of the simulation lies in the intensive computation of a tomographic reconstruct or (TR), which is used

  10. Present state and development of positron tomographs

    International Nuclear Information System (INIS)

    Allemand, R.; Gariod, R.; Laval, M.; Tournier, F.

    1979-01-01

    This document presents the main characteristics of positron tomographs and analyses the relative importance of the parameters to be taken into consideration in the design of a tomograph: on the one hand, the physical parameters linked to the measurement of the annihilation photons by time coincidence and, on the other, the geometrical and technological parameters of prime importance in minimizing the many spurious effects. The last part endeavours to show this sort of instrumentation has evolved. Using the results obtained in our laboratory by mathematical simulation, the expected advantages are presented on the picture quality of the time of flight measurement of annihilation photons. Where the physical aspects of this method are concerned, the advantage of using cesium fluoride as scintillator is demonstrated [fr

  11. Unaccompanied adolescents seeking asylum: Poorer mental health under a restrictive reception

    NARCIS (Netherlands)

    Reijneveld, S.A.; Boer, J.B.de; Bean, T.; Korfker, D.G.

    2005-01-01

    We assessed the effects of a stringent reception policy on the mental health of unaccompanied adolescent asylum seekers by comparing the mental health of adolescents in a restricted campus reception setting and in a setting offering more autonomy (numbers [response rates]: 69 [93%] and 53 [69%],

  12. The bar coil for NMR tomograph

    International Nuclear Information System (INIS)

    Bogorodzki, P.; Piatkowski, A.; Wasielewski, J.

    1995-01-01

    The bar coil (bi-planar) for the NMR tomograph, designed for medical diagnostics, has been described. The tests of coil shown that it generates good homogenous magnetic field in a big volume what results in improving of the signal-to-noise ratio

  13. Tomographic Reconstruction from a Few Views: A Multi-Marginal Optimal Transport Approach

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, I., E-mail: isabelle.abraham@cea.fr [CEA Ile de France (France); Abraham, R., E-mail: romain.abraham@univ-orleans.fr; Bergounioux, M., E-mail: maitine.bergounioux@univ-orleans.fr [Université d’Orléans, UFR Sciences, MAPMO, UMR 7349 (France); Carlier, G., E-mail: carlier@ceremade.dauphine.fr [CEREMADE, UMR CNRS 7534, Université Paris IX Dauphine, Pl. de Lattre de Tassigny (France)

    2017-02-15

    In this article, we focus on tomographic reconstruction. The problem is to determine the shape of the interior interface using a tomographic approach while very few X-ray radiographs are performed. We use a multi-marginal optimal transport approach. Preliminary numerical results are presented.

  14. Project, building and utilization of a tomograph of micro metric resolution to application in soil science

    International Nuclear Information System (INIS)

    Macedo, Alvaro; Torre Neto, Andre; Cruvinel, Paulo Estevao; Crestana, Silvio

    1996-08-01

    This paper describes the project , building and utilization of a tomograph of micro metric resolution in soil science. It describes the problems involved in soil's science study and it describes the system and methodology

  15. Reconstruction of tomographic image from x-ray projections of a few views

    International Nuclear Information System (INIS)

    Kobayashi, Fujio; Yamaguchi, Shoichiro

    1982-01-01

    Computer tomographs have progressed rapidly, and in the latest high performance types, the photographing time has been shortened to less than 5 sec, but the clear images of hearts have not yet been obtained. The X-ray tomographs used so far irradiate X-ray from many directions and measure the projected data, but by limiting projection direction to a small number, it was planned to shorter the X-ray photographing time and to reduce X-ray exposure as the objective of this study. In this paper, a method is proposed, by which tomographic images are reconstructed from projected data in a small number of direction by generalized inverse matrix penalty method. This method is the calculation method newly devised by the authors for this purpose. It is a kind of the nonlinear planning method added with the restrictive condition using a generalized inverse matrix, and it is characterized by the simple calculation procedure and rapid convergence. Moreover, the effect on reconstructed images when errors are included in projected data was examined. Also, the simple computer simulation to reconstruct tomographic images using the projected data in four directions was performed, and the usefulness of this method was confirmed. It contributes to the development of superhigh speed tomographs in future. (Kako, I.)

  16. Bioinspired magnetic reception and multimodal sensing.

    Science.gov (United States)

    Taylor, Brian K

    2017-08-01

    Several animals use Earth's magnetic field in concert with other sensor modes to accomplish navigational tasks ranging from local homing to continental scale migration. However, despite extensive research, animal magnetic reception remains poorly understood. Similarly, the Earth's magnetic field offers a signal that engineered systems can leverage to navigate in environments where man-made positioning systems such as GPS are either unavailable or unreliable. This work uses a behavioral strategy inspired by the migratory behavior of sea turtles to locate a magnetic goal and respond to wind when it is present. Sensing is performed using a number of distributed sensors. Based on existing theoretical biology considerations, data processing is performed using combinations of circles and ellipses to exploit the distributed sensing paradigm. Agent-based simulation results indicate that this approach is capable of using two separate magnetic properties to locate a goal from a variety of initial conditions in both noiseless and noisy sensory environments. The system's ability to locate the goal appears robust to noise at the cost of overall path length.

  17. Approximation of Measurement Results of “Emergency” Signal Reception Probability

    Directory of Open Access Journals (Sweden)

    Gajda Stanisław

    2017-08-01

    Full Text Available The intended aim of this article is to present approximation results of the exemplary measurements of EMERGENCY signal reception probability. The probability is under-stood as a distance function between the aircraft and a ground-based system under established conditions. The measurements were approximated using the properties of logistic functions. This probability, as a distance function, enables to determine the range of the EMERGENCY signal for a pre-set confidence level.

  18. Tomographic ventricular reconstruction using multiple view first-pass radionuclide angiography

    International Nuclear Information System (INIS)

    Lacy, J.L.; Ball, M.E.; Verani, M.S.; Wiles, H.; Roberts, R.

    1985-01-01

    In first-pass radionuclide angiography (FPRA) images of both left and right ventricles are uncontaminated by adjacent structures. Thus, the problem of tomographic reconstruction is vastly simplified compared to equilibrium blood pool imaging in which all structures are imaged simultaneously. Tomographic reconstruction from a limited number of views may thus be possible. A simple filtered interpolative back-projection reconstruction technique was employed. In this technique interpolation was used between sectional distributions at successive angles. Interpolations yielding 9 and 13 back projection angles of 22.5 0 and 15 0 were evaluated. Ventricular borders were obtained in each back-projected tomographic slice by location of the intensity level which provided correct total ventricular volume. Cast cross sections were quantitatively well represented by these borders. This ventricular border definition algorithm forms the basis for applications of the technique in animals and humans

  19. Tomographic image reconstruction using training images

    DEFF Research Database (Denmark)

    Soltani, Sara; Andersen, Martin Skovgaard; Hansen, Per Christian

    2017-01-01

    We describe and examine an algorithm for tomographic image reconstruction where prior knowledge about the solution is available in the form of training images. We first construct a non-negative dictionary based on prototype elements from the training images; this problem is formulated within...

  20. Are They Listening? Parental Social Coaching and Parenting Emotional Climate Predict Adolescent Receptivity.

    Science.gov (United States)

    Gregson, Kim D; Erath, Stephen A; Pettit, Gregory S; Tu, Kelly M

    2016-12-01

    Associations linking parenting emotional climate and quality of parental social coaching with young adolescents' receptivity to parental social coaching were examined (N = 80). Parenting emotional climate was assessed with adolescent-reported parental warmth and hostility. Quality of parental social coaching (i.e., prosocial advice, benign framing) was assessed via parent-report and behavioral observations during a parent-adolescent discussion about negative peer evaluation. An adolescent receptivity latent variable score was derived from observations of adolescents' behavior during the discussion, change in adolescents' peer response plan following the discussion, and adolescent-reported tendency to seek social advice from the parent. Parenting climate moderated associations between coaching and receptivity: Higher quality coaching was associated with greater receptivity in the context of a more positive climate. Analyses suggested a stronger association between coaching and receptivity among younger compared to older adolescents. © 2015 The Authors. Journal of Research on Adolescence © 2015 Society for Research on Adolescence.

  1. 3D Tomographic Image Reconstruction using CUDA C

    International Nuclear Information System (INIS)

    Dominguez, J. S.; Assis, J. T.; Oliveira, L. F. de

    2011-01-01

    This paper presents the study and implementation of a software for three dimensional reconstruction of images obtained with a tomographic system using the capabilities of Graphic Processing Units(GPU). The reconstruction by filtered back-projection method was developed using the CUDA C, for maximum utilization of the processing capabilities of GPUs to solve computational problems with large computational cost and highly parallelizable. It was discussed the potential of GPUs and shown its advantages to solving this kind of problems. The results in terms of runtime will be compared with non-parallelized implementations and must show a great reduction of processing time. (Author)

  2. Teaching receptive naming of Chinese characters to children with autism by incorporating echolalia.

    OpenAIRE

    Leung, J P; Wu, K I

    1997-01-01

    The facilitative effect of incorporating echolalia on teaching receptive naming of Chinese characters to children with autism was assessed. In Experiment 1, echoing the requested character name prior to the receptive naming task facilitated matching a character to its name. In addition, task performance was consistently maintained only when echolalia preceded the receptive manual response. Positive results from generalization tests suggested that learned responses occurred across various nove...

  3. Receptivity to television fast-food restaurant marketing and obesity among U.S. youth.

    Science.gov (United States)

    McClure, Auden C; Tanski, Susanne E; Gilbert-Diamond, Diane; Adachi-Mejia, Anna M; Li, Zhigang; Li, Zhongze; Sargent, James D

    2013-11-01

    Advertisement of fast food on TV may contribute to youth obesity. The goal of the study was to use cued recall to determine whether TV fast-food advertising is associated with youth obesity. A national sample of 2541 U.S. youth, aged 15-23 years, were surveyed in 2010-2011; data were analyzed in 2012. Respondents viewed a random subset of 20 advertisement frames (with brand names removed) selected from national TV fast-food restaurant advertisements (n=535) aired in the previous year. Respondents were asked if they had seen the advertisement, if they liked it, and if they could name the brand. A TV fast-food advertising receptivity score (a measure of exposure and response) was assigned; a 1-point increase was equivalent to affirmative responses to all three queries for two separate advertisements. Adjusted odds of obesity (based on self-reported height and weight), given higher TV fast-food advertising receptivity, are reported. The prevalence of overweight and obesity, weighted to the U.S. population, was 20% and 16%, respectively. Obesity, sugar-sweetened beverage consumption, fast-food restaurant visit frequency, weekday TV time, and TV alcohol advertising receptivity were associated with higher TV fast-food advertising receptivity (median=3.3 [interquartile range: 2.2-4.2]). Only household income, TV time, and TV fast-food advertising receptivity retained multivariate associations with obesity. For every 1-point increase in TV fast-food advertising receptivity score, the odds of obesity increased by 19% (OR=1.19, 95% CI=1.01, 1.40). There was no association between receptivity to televised alcohol advertisements or fast-food restaurant visit frequency and obesity. Using a cued-recall assessment, TV fast-food advertising receptivity was found to be associated with youth obesity. © 2013 American Journal of Preventive Medicine.

  4. Receptivity to Television Fast-Food Restaurant Marketing and Obesity Among U.S. Youth

    Science.gov (United States)

    McClure, Auden C.; Tanski, Susanne E.; Gilbert-Diamond, Diane; Adachi-Mejia, Anna M.; Li, Zhigang; Li, Zhongze; Sargent, James D.

    2013-01-01

    Background Advertisement of fast food on TV may contribute to youth obesity. Purpose The goal of the study was to use cued recall to determine whether TV fast-food advertising is associated with youth obesity. Methods A national sample of 2541 U.S. youth, aged 15–23 years, were surveyed in 2010–2011; data were analyzed in 2012. Respondents viewed a random subset of 20 advertisement frames (with brand names removed) selected from national TV fast-food restaurant advertisements (n=535) aired in the previous year. Respondents were asked if they had seen the advertisement, if they liked it, and if they could name the brand. A TV fast-food advertising receptivity score (a measure of exposure and response) was assigned; a 1-point increase was equivalent to affirmative responses to all three queries for two separate advertisements. Adjusted odds of obesity (based on self-reported height and weight), given higher TV fast-food advertising receptivity, are reported. Results The prevalence of overweight and obesity, weighted to the U.S. population, was 20% and 16%, respectively. Obesity, sugar-sweetened beverage consumption, fast-food restaurant visit frequency, weekday TV time, and TV alcohol advertising receptivity were associated with higher TV fast-food advertising receptivity (median=3.3 [interquartile range: 2.2–4.2]). Only household income, TV time, and TV fast-food advertising receptivity retained multivariate associations with obesity. For every 1-point increase in TV fast-food advertising receptivity score, the odds of obesity increased by 19% (OR=1.19, 95% CI=1.01, 1.40). There was no association between receptivity to televised alcohol advertisements or fast-food restaurant visit frequency and obesity. Conclusions Using a cued-recall assessment, TV fast-food advertising receptivity was found to be associated with youth obesity. PMID:24139768

  5. How will military/civilian coordination work for reception of mass casualties from overseas?

    Science.gov (United States)

    Mackenzie, Colin; Donohue, John; Wasylina, Philip; Cullum, Woodrow; Hu, Peter; Lam, David M

    2009-01-01

    In Maryland, there have been no military/civilian training exercises of the Medical Mutual Aid Agreement for >20 years. The aims of this paper are to describe the National Disaster Medical System (NDMS), to coordinate military and civilian medical mutual aid in response to arrival of overseas mass casualties, and to evaluate the mass-casualty reception and bed "surge" capacity of Maryland NDMS Hospitals. Three tabletop exercises and a functional exercise were performed using a simulated, overseas, military mass-casualty event. The first tabletop exercise was with military and civilian NMDS partners. The second tested the revised NDMS activation plan. The third exercised the Authorities of State Emergency Medical System and Walter Reed Army Medical Center Directors of Emergency Medicine over Maryland NDMS hospitals, and their Medical Mutual Aid Agreement. The functional exercise used Homeland Security Exercise Evaluation Program tools to evaluate reception, triage, staging, and transportation of 160 notional patients (including 20 live, moulaged "patients") and one canine. The first tabletop exercise identified deficiencies in operational protocols for military/civilian mass-casualty reception, triage, treatment, and problems with sharing a Unified Command. The second found improvements in the revised NDMS activation plan. The third informed expectations for NDMS hospitals. In the functional exercise, all notional patients were received, triaged, dispatched, and accounted in military and five civilian hospitals within two hours. The canine revealed deficiencies in companion/military animal reception, holding, treatment, and evacuation. Three working groups were suggested: (1) to ensure 100% compliance with triage tags, patient accountability, and return of equipment used in mass casualty events and exercises; (2) to investigate making information technology and imaging networks available for Emergency Operation Centers and Incident Command; and (3) to establish NDMS

  6. Pressure spectra from single-snapshot tomographic PIV

    Science.gov (United States)

    Schneiders, Jan F. G.; Avallone, Francesco; Pröbsting, Stefan; Ragni, Daniele; Scarano, Fulvio

    2018-03-01

    The power spectral density and coherence of temporal pressure fluctuations are obtained from low-repetition-rate tomographic PIV measurements. This is achieved by extension of recent single-snapshot pressure evaluation techniques based upon the Taylor's hypothesis (TH) of frozen turbulence and vortex-in-cell (VIC) simulation. Finite time marching of the measured instantaneous velocity fields is performed using TH and VIC. Pressure is calculated from the resulting velocity time series. Because of the theoretical limitations, the finite time marching can be performed until the measured flow structures are convected out of the measurement volume. This provides a lower limit of resolvable frequency range. An upper limit is given by the spatial resolution of the measurements. Finite time-marching approaches are applied to low-repetition-rate tomographic PIV data of the flow past a straight trailing edge at 10 m/s. Reference results of the power spectral density and coherence are obtained from surface pressure transducers. In addition, the results are compared to state-of-the-art experimental data obtained from time-resolved tomographic PIV performed at 10 kHz. The time-resolved approach suffers from low spatial resolution and limited maximum acquisition frequency because of hardware limitations. Additionally, these approaches strongly depend upon the time kernel length chosen for pressure evaluation. On the other hand, the finite time-marching approaches make use of low-repetition-rate tomographic PIV measurements that offer higher spatial resolution. Consequently, increased accuracy of the power spectral density and coherence of pressure fluctuations are obtained in the high-frequency range, in comparison to the time-resolved measurements. The approaches based on TH and VIC are found to perform similarly in the high-frequency range. At lower frequencies, TH is found to underestimate coherence and intensity of the pressure fluctuations in comparison to time-resolved PIV

  7. Risk factors for low receptive vocabulary abilities in the preschool and early school years in the longitudinal study of Australian children.

    Directory of Open Access Journals (Sweden)

    Daniel Christensen

    Full Text Available Receptive vocabulary development is a component of the human language system that emerges in the first year of life and is characterised by onward expansion throughout life. Beginning in infancy, children's receptive vocabulary knowledge builds the foundation for oral language and reading skills. The foundations for success at school are built early, hence the public health policy focus on reducing developmental inequalities before children start formal school. The underlying assumption is that children's development is stable, and therefore predictable, over time. This study investigated this assumption in relation to children's receptive vocabulary ability. We investigated the extent to which low receptive vocabulary ability at 4 years was associated with low receptive vocabulary ability at 8 years, and the predictive utility of a multivariate model that included child, maternal and family risk factors measured at 4 years. The study sample comprised 3,847 children from the first nationally representative Longitudinal Study of Australian Children (LSAC. Multivariate logistic regression was used to investigate risks for low receptive vocabulary ability from 4-8 years and sensitivity-specificity analysis was used to examine the predictive utility of the multivariate model. In the multivariate model, substantial risk factors for receptive vocabulary delay from 4-8 years, in order of descending magnitude, were low receptive vocabulary ability at 4 years, low maternal education, and low school readiness. Moderate risk factors, in order of descending magnitude, were low maternal parenting consistency, socio-economic area disadvantage, low temperamental persistence, and NESB status. The following risk factors were not significant: One or more siblings, low family income, not reading to the child, high maternal work hours, and Aboriginal or Torres Strait Islander ethnicity. The results of the sensitivity-specificity analysis showed that a well

  8. Effect of leading-edge geometry on boundary-layer receptivity to freestream sound

    Science.gov (United States)

    Lin, Nay; Reed, Helen L.; Saric, W. S.

    1991-01-01

    The receptivity to freestream sound of the laminar boundary layer over a semi-infinite flat plate with an elliptic leading edge is simulated numerically. The incompressible flow past the flat plate is computed by solving the full Navier-Stokes equations in general curvilinear coordinates. A finite-difference method which is second-order accurate in space and time is used. Spatial and temporal developments of the Tollmien-Schlichting wave in the boundary layer, due to small-amplitude time-harmonic oscillations of the freestream velocity that closely simulate a sound wave travelling parallel to the plate, are observed. The effect of leading-edge curvature is studied by varying the aspect ratio of the ellipse. The boundary layer over the flat plate with a sharper leading edge is found to be less receptive. The relative contribution of the discontinuity in curvature at the ellipse-flat-plate juncture to receptivity is investigated by smoothing the juncture with a polynomial. Continuous curvature leads to less receptivity. A new geometry of the leading edge, a modified super ellipse, which provides continuous curvature at the juncture with the flat plate, is used to study the effect of continuous curvature and inherent pressure gradient on receptivity.

  9. Tomographic site characterization using CPT, ERT, and GPR. Innovative Technology Summary Report

    International Nuclear Information System (INIS)

    None

    2000-01-01

    ARA developed a geophysical tomographic system that incorporates results from Electrical Resistivity Tomography (ERT) measurements and Ground Penetrating Radar (GPR) Tomography measurements. Both methods are useful for imaging subsurface structures and processes, however, GPR is more effective in sandy material and ERT is more effective in clayey material. CPT or drilling is used to deploy the electrodes in the subsurface

  10. Positioning of Nuclear Fuel Assemblies by Means of Image Analysis on Tomographic Data

    International Nuclear Information System (INIS)

    Troeng, Mats

    2005-06-01

    A tomographic measurement technique for nuclear fuel assemblies has been developed at the Department of Radiation Sciences at Uppsala University. The technique requires highly accurate information about the position of the measured nuclear fuel assembly relative to the measurement equipment. In experimental campaigns performed earlier, separate positioning measurements have therefore been performed in connection to the tomographic measurements. In this work, another positioning approach has been investigated, which requires only the collection of tomographic data. Here, a simplified tomographic reconstruction is performed, whereby an image is obtained. By performing image analysis on this image, the lateral and angular position of the fuel assembly can be determined. The position information can then be used to perform a more accurate tomographic reconstruction involving detailed physical modeling. Two image analysis techniques have been developed in this work. The stability of the two techniques with respect to some central parameters has been studied. The agreement between these image analysis techniques and the previously used positioning technique was found to meet the desired requirements. Furthermore, it has been shown that the image analysis techniques offer more detailed information than the previous technique. In addition, its off-line analysis properties reduce the need for valuable measurement time. When utilizing the positions obtained from the image analysis techniques in tomographic reconstructions of the rod-by-rod power distribution, the repeatability of the reconstructed values was improved. Furthermore, the reconstructions resulted in better agreement to theoretical data

  11. Decomposition of time-resolved tomographic PIV

    NARCIS (Netherlands)

    Schmid, P.J.; Violato, D.; Scarano, F.

    2012-01-01

    An experimental study has been conducted on a transitional water jet at a Reynolds number of Re = 5,000. Flow fields have been obtained by means of time-resolved tomographic particle image velocimetry capturing all relevant spatial and temporal scales. The measured threedimensional flow fields have

  12. Connections model for tomographic images reconstruction

    International Nuclear Information System (INIS)

    Rodrigues, R.G.S.; Pela, C.A.; Roque, S.F. A.C.

    1998-01-01

    This paper shows an artificial neural network with an adequately topology for tomographic image reconstruction. The associated error function is derived and the learning algorithm is make. The simulated results are presented and demonstrate the existence of a generalized solution for nets with linear activation function. (Author)

  13. Tomographic methods in nuclear medicine

    International Nuclear Information System (INIS)

    Ahluwalia, B.D.

    1989-01-01

    This book is a review of the various approaches to tomographic imaging that have been pursued in nuclear medicine. The evolution of single photon emission computed tomography (SPECT) is discussed in detail, and the major classes of instrumentation are represented. A section on positron emission tomography is also included, but is rather brief and may serve only as a general introduction

  14. Mesooptical microscope as a tomographical device

    International Nuclear Information System (INIS)

    Soroko, L.M.

    1989-01-01

    It is shown that there are at least four regions which are common for the mesooptical microscopes, on the one hand, and for the reconstructed tomography, on the other hand. The following characteristics of the mesooptical microscope show the tomographical properties: the structure of the output data concerning the orientation and the position in space of the straight-line objects going at small angles with the perpendicular to the given tomographic plane, the behaviour of the two-dimensional fourier-transform of the straight-line object in the course of the rotation of this object with respect to the specified axis in space, the scanning algorithm of the nuclear emulsion volume by the fence-like illuminated region in the mesooptical microscope for searching for particle tracks going parallel to the optical axis of the microscope, and, finally, the fact that the mesooptical images of the straight-line particle tracks with a common vertex in the nuclear emulsion lie on the sinogram. 12 refs.; 16 figs

  15. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    Abele, M.

    1983-01-01

    A computerized tomographic scanning apparatus suitable for diagnosis and for improving target identification in stereotactic neurosurgery is described. It consists of a base, a source of penetrating energy, a detector which produces scanning signals and detector positioning means. A frame with top and bottom arms secures the detector and source to the top and bottom arms respectively. A drive mechanism rotates the frame about an axis along which the frame may also be moved. Finally, the detector may be moved relative to the bottom arm in a direction contrary to the rotation of the frame. (U.K.)

  16. Problems of generation and reception of gravitational waves. [Review

    Energy Technology Data Exchange (ETDEWEB)

    Pisarev, A F [Joint Inst. for Nuclear Research, Dubna (USSR)

    1975-01-01

    The present day status of the problems of gravitation, wave radiation and reception is surveyed. The physical presentation and mathematical description of the processes of radiation, propagation and interaction of gravitation waves with matter and the electromagnetic field are given. The experiments on the search for gravitation waves of astophysical nature are analysed. The laboratory and cosmic sources of these waves and the methods of their reception are described. Special attention is drawn to the analysis of the proposals to perform a complete laboratory gravitation wave experiment.

  17. From conciliar ecumenism to transformative receptive ecumenism

    Directory of Open Access Journals (Sweden)

    Mary-Anne Plaatjies van Huffel

    2017-09-01

    Full Text Available This article attends to ecumenicity as the second reformation. The ecumenical organisations and agencies hugely influenced the theological praxis and reflection of the church during the past century. The First World Council of Churches (WCC Assembly in Amsterdam, the Netherlands, has been described as the most significant event in church history since the Reformation during the past decade. We saw the emergence of two initiatives that are going to influence ecumenical theology and practice in future, namely the Receptive Ecumenism and Catholic Learning research project, based in Durham, United Kingdom, and the International Theological Colloquium for Transformative Ecumenism of the WCC. Both initiatives constitute a fresh approach in methodology to ecumenical theology and practice. Attention will be given in this article to conciliar ecumenism, receptive ecumenism, transformative ecumenism and its implications for the development of an African transformative receptive ecumenism. In doing so, we should take cognisance of what Küng says about a confessionalist ghetto mentality: ‘We must avoid a confessionalistic ghetto mentality. Instead we should espouse an ecumenical vision that takes into consideration the world religions as well as contemporary ideologies: as much tolerance as possible toward those things outside the Church, toward the religious in general, and the human in general, and the development of that which is specifically Christian belong together!’

  18. Adolescents with and without gestational cocaine exposure: Longitudinal analysis of inhibitory control, memory and receptive language.

    Science.gov (United States)

    Betancourt, Laura M; Yang, Wei; Brodsky, Nancy L; Gallagher, Paul R; Malmud, Elsa K; Giannetta, Joan M; Farah, Martha J; Hurt, Hallam

    2011-01-01

    Preclinical studies of gestational cocaine exposure (GCE) show evidence of changes in brain function at the anatomical, physiological, and behavioral levels, to include effects on developing dopaminergic systems. In contrast, human studies have produced less consistent results, with most showing small effects or no effects on developmental outcomes. Important changes in brain structure and function occur through adolescence, therefore it is possible that prenatal cocaine exposure has latent effects on neurocognitive (NC) outcome that do not manifest until adolescence or young adulthood. We examined NC function using a set of 5 tasks designed to tap 4 different systems: inhibitory control, working memory, receptive language, and incidental memory. For each NC task, data were collected longitudinally at ages 12, 14.5 and 17 years and examined using generalized estimating equations. One hundred and nine children completed at least two of the three evaluations. Covariates included in the final model were assessment number, gender, participant age at first assessment, caregiver depression, and two composites from the Home Observation for Measurement of the Environment (HOME), Environmental Stimulation and Parental Nurturance. We found no cocaine effects on inhibitory control, working memory, or receptive language (p=0.18). GCE effects were observed on incidental face memory task (p=0.055), and GCE by assessment number interaction effects were seen on the incidental word memory task (p=0.031). Participant performance on inhibitory control, working memory, and receptive language tasks improved over time. HOME Environmental Stimulation composite was associated with better receptive language functioning. With a larger sample size smaller differences between groups may have been detected. This report shows no evidence of latent effects of GCE on inhibitory control, working memory, or receptive language. GCE effects were observed on the incidental face memory task, and GCE by

  19. 47 CFR 73.825 - Protection to reception of TV channel 6.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Protection to reception of TV channel 6. 73.825... RADIO BROADCAST SERVICES Low Power FM Broadcast Stations (LPFM) § 73.825 Protection to reception of TV... separation distances in the following table are met with respect to all full power TV Channel 6 stations. FM...

  20. Tomographic Small-Animal Imaging Using a High-Resolution Semiconductor Camera

    Science.gov (United States)

    Kastis, GA; Wu, MC; Balzer, SJ; Wilson, DW; Furenlid, LR; Stevenson, G; Barber, HB; Barrett, HH; Woolfenden, JM; Kelly, P; Appleby, M

    2015-01-01

    We have developed a high-resolution, compact semiconductor camera for nuclear medicine applications. The modular unit has been used to obtain tomographic images of phantoms and mice. The system consists of a 64 x 64 CdZnTe detector array and a parallel-hole tungsten collimator mounted inside a 17 cm x 5.3 cm x 3.7 cm tungsten-aluminum housing. The detector is a 2.5 cm x 2.5 cm x 0.15 cm slab of CdZnTe connected to a 64 x 64 multiplexer readout via indium-bump bonding. The collimator is 7 mm thick, with a 0.38 mm pitch that matches the detector pixel pitch. We obtained a series of projections by rotating the object in front of the camera. The axis of rotation was vertical and about 1.5 cm away from the collimator face. Mouse holders were made out of acrylic plastic tubing to facilitate rotation and the administration of gas anesthetic. Acquisition times were varied from 60 sec to 90 sec per image for a total of 60 projections at an equal spacing of 6 degrees between projections. We present tomographic images of a line phantom and mouse bone scan and assess the properties of the system. The reconstructed images demonstrate spatial resolution on the order of 1–2 mm. PMID:26568676

  1. Housing Service: Receptions of the CERN and St.-Genis-Pouilly Hostels

    CERN Multimedia

    2005-01-01

    Opening times Please note the new and definitive opening times of the Receptions of the hostels on the Swiss site of CERN and in St. Genis : CERN hostels St.-Genis hostel from Monday to Friday 7:30 - 19:30 8:00 - 12:00 16:00 - 19:00 Saturday 9:00 - 13:00 closed Sunday 9:00 - 13:00 closed Outside these times keys to rooms reserved in advance can be obtained from the guards on duty at the main entrance to the Meyrin, Switzerland, CERN site (Gate B), where they are deposited some fifteen minutes after the closure of the Reception. As for the St. Genis hostel, for arrivals on Saturdays and Sundays, the keys are deposited with the guards in advance on the preceding Friday evening. Reminder : reservations, whether for the CERN hostels or the St. Genis hostel, are available through the Reception of the CERN hostels. Once the reservation has been confirmed, in the case of St. Genis, all other business, including payment, is dealt with by the St. Genis hostel reception. As far as possible, all r...

  2. The Critical Reception of Lewis Nordan

    DEFF Research Database (Denmark)

    Bjerre, Thomas Ærvold

    2010-01-01

    The essay covers the critical reception of Mississippi-writer Lewis Nordan from his debut in 1983 to the boost in scholarly attention in the new millennium. The essay covers newspaper reviews but pays particular attention to the many academic essays that have placed Nordan as a writer...

  3. Effect of Shot Noise on Simultaneous Sensing in Frequency Division Multiplexed Diffuse Optical Tomographic Imaging Process.

    Science.gov (United States)

    Jang, Hansol; Lim, Gukbin; Hong, Keum-Shik; Cho, Jaedu; Gulsen, Gultekin; Kim, Chang-Seok

    2017-11-28

    Diffuse optical tomography (DOT) has been studied for use in the detection of breast cancer, cerebral oxygenation, and cognitive brain signals. As optical imaging studies have increased significantly, acquiring imaging data in real time has become increasingly important. We have developed frequency-division multiplexing (FDM) DOT systems to analyze their performance with respect to acquisition time and imaging quality, in comparison with the conventional time-division multiplexing (TDM) DOT. A large tomographic area of a cylindrical phantom 60 mm in diameter could be successfully reconstructed using both TDM DOT and FDM DOT systems. In our experiment with 6 source-detector (S-D) pairs, the TDM DOT and FDM DOT systems required 6.18 and 1 s, respectively, to obtain a single tomographic data set. While the absorption coefficient of the reconstruction image was underestimated in the case of the FDM DOT, we experimentally confirmed that the abnormal region can be clearly distinguished from the background phantom using both methods.

  4. Effect of Shot Noise on Simultaneous Sensing in Frequency Division Multiplexed Diffuse Optical Tomographic Imaging Process

    Directory of Open Access Journals (Sweden)

    Hansol Jang

    2017-11-01

    Full Text Available Diffuse optical tomography (DOT has been studied for use in the detection of breast cancer, cerebral oxygenation, and cognitive brain signals. As optical imaging studies have increased significantly, acquiring imaging data in real time has become increasingly important. We have developed frequency-division multiplexing (FDM DOT systems to analyze their performance with respect to acquisition time and imaging quality, in comparison with the conventional time-division multiplexing (TDM DOT. A large tomographic area of a cylindrical phantom 60 mm in diameter could be successfully reconstructed using both TDM DOT and FDM DOT systems. In our experiment with 6 source-detector (S-D pairs, the TDM DOT and FDM DOT systems required 6.18 and 1 s, respectively, to obtain a single tomographic data set. While the absorption coefficient of the reconstruction image was underestimated in the case of the FDM DOT, we experimentally confirmed that the abnormal region can be clearly distinguished from the background phantom using both methods.

  5. Collimated trans-axial tomographic scintillation camera

    International Nuclear Information System (INIS)

    1980-01-01

    The principal problem in trans-axial tomographic radioisotope scanning is the length of time required to obtain meaningful data. Patient movement and radioisotope migration during the scanning period can cause distortion of the image. The object of this invention is to reduce the scanning time without degrading the images obtained. A system is described in which a scintillation camera detector is moved to an orbit about the cranial-caudal axis relative to the patient. A collimator is used in which lead septa are arranged so as to admit gamma rays travelling perpendicular to this axis with high spatial resolution and those travelling in the direction of the axis with low spatial resolution, thus increasing the rate of acceptance of radioactive events to contribute to the positional information obtainable without sacrificing spatial resolution. (author)

  6. Computed-tomographic determination of mineral content of bones

    International Nuclear Information System (INIS)

    Delov, I.; Tabakov, S.

    1988-01-01

    The problem of precise computed-tomographic densitometry of the mineral content of bones is pointed out. A method is proposed including the use of standard density and observance of definite radiation, scanning and image estimation parameters. A good correlation of the results obtained for the mineral content of the lumbar vertebrae with literature data are reported. A method is also described for determining the mineral content of tubular bones based on densiprofile check-up of the computed-tomographic density. The procedure takes 10-15 minutes and includes 1 or 2 scans. It might therefore gain wide acceptance for the diagnosis and tracing of osteoporosis and other osteopathies associated with distrorted calcium metabolism

  7. Data and Analysis from a Time-Resolved Tomographic Optical Beam Diagnostic

    International Nuclear Information System (INIS)

    Frayer, Daniel K.; Johnson, Douglas; Ekdahl, Carl

    2010-01-01

    An optical tomographic diagnostic instrument developed for the acquisition of high-speed time-resolved images has been fielded at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed for the creation of time histories of electron-beam cross section through the collection of Cerenkov light. Four optical lines of sight optically collapse an image and relay projections via an optical fiber relay to recording instruments; a tomographic reconstruction algorithm creates the time history. Because the instrument may be operated in an adverse environment, it may be operated, adjusted, and calibrated remotely. The instrument was operated over the course of various activities during and after DARHT commissioning, and tomographic reconstructions reported verifiable beam characteristics. Results from the collected data and reconstructions and analysis of the data are discussed.

  8. MOBIUS-STRIP-LIKE COLUMNAR FUNCTIONAL CONNECTIONS ARE REVEALED IN SOMATO-SENSORY RECEPTIVE FIELD CENTROIDS.

    Directory of Open Access Journals (Sweden)

    James Joseph Wright

    2014-10-01

    Full Text Available Receptive fields of neurons in the forelimb region of areas 3b and 1 of primary somatosensory cortex, in cats and monkeys, were mapped using extracellular recordings obtained sequentially from nearly radial penetrations. Locations of the field centroids indicated the presence of a functional system, in which cortical homotypic representations of the limb surfaces are entwined in three-dimensional Mobius-strip-like patterns of synaptic connections. Boundaries of somatosensory receptive field in nested groups irregularly overlie the centroid order, and are interpreted as arising from the superposition of learned connections upon the embryonic order. Since the theory of embryonic synaptic self-organisation used to model these results was devised and earlier used to explain findings in primary visual cortex, the present findings suggest the theory may be of general application throughout cortex, and may reveal a modular functional synaptic system, which, only in some parts of the cortex, and in some species, is manifest as anatomical ordering into columns.

  9. Tomographic imaging of subducted lithosphere below northwest Pacific island arcs

    Science.gov (United States)

    Van Der Hilst, R.; Engdahl, R.; Spakman, W.; Nolet, G.

    1991-01-01

    The seismic tomography problem does not have a unique solution, and published tomographic images have been equivocal with regard to the deep structure of subducting slabs. An improved tomographic method, using a more realistic background Earth model and surf ace-reflected as well as direct seismic phases, shows that slabs beneath the Japan and Izu Bonin island arcs are deflected at the boundary between upper and lower mantle, whereas those beneath the northern Kuril and Mariana arcs sink into the lower mantle.

  10. Difficulties Using Standardized Tests to Identify the Receptive Expressive Gap in Bilingual Children's Vocabularies.

    Science.gov (United States)

    Gibson, Todd A; Oller, D Kimbrough; Jarmulowicz, Linda

    2018-03-01

    Receptive standardized vocabulary scores have been found to be much higher than expressive standardized vocabulary scores in children with Spanish as L1, learning L2 (English) in school (Gibson et al., 2012). Here we present evidence suggesting the receptive-expressive gap may be harder to evaluate than previously thought because widely-used standardized tests may not offer comparable normed scores. Furthermore monolingual Spanish-speaking children tested in Mexico and monolingual English-speaking children in the US showed other, yet different statistically significant discrepancies between receptive and expressive scores. Results suggest comparisons across widely used standardized tests in attempts to assess a receptive-expressive gap are precarious.

  11. Registration of synthetic tomographic projection data sets using cross-correlation

    International Nuclear Information System (INIS)

    Fitchard, E.E.; Aldridge, J.S.; Reckwerdt, P.J.; Mackie, T.R.

    1998-01-01

    Tomographic registration, a method that makes possible accurate patient registration directly from projection data, consists of three processing steps: (i) manual coarse positioning, (ii) tomographic projection set acquisition, and (iii) computer mediated refined positioning. In the coarse positioning stage, the degree of patient alignment is comparable with that achieved with the standard radiotherapy set-up. However, the accuracy requirements are somewhat more relaxed in that meticulous alignment of the patient using external laser indicators is not necessary. Instead, tomographic projection sets are compared with planning CTs in order to achieve improved patient set-up. The projection sets are cross-correlated to obtain the best-fit translation and rotation offsets. The algorithm has been tested on synthetic data with the incorporation of varying amounts of Gaussian pseudo-random noise. These tests demonstrate the algorithm's stability and also confirm that alignment can be achieved with an accuracy of less than one projection pixel. (author)

  12. Remote diagnosis via a telecommunication satellite--ultrasonic tomographic image transmission experiments.

    Science.gov (United States)

    Nakajima, I; Inokuchi, S; Tajima, T; Takahashi, T

    1985-04-01

    An experiment to transmit ultrasonic tomographic section images required for remote medical diagnosis and care was conducted using the mobile telecommunication satellite OSCAR-10. The images received showed the intestinal condition of a patient incapable of verbal communication, however the image screen had a fairly coarse particle structure. On the basis of these experiments, were considered as the transmission of ultrasonic tomographic images extremely effective in remote diagnosis.

  13. Effects of Humor Production, Humor Receptivity, and Physical Attractiveness on Partner Desirability

    Directory of Open Access Journals (Sweden)

    Michelle Tornquist

    2015-10-01

    Full Text Available This study examined women’s and men’s preferences for humor production and humor receptivity in long-term and short-term relationships, and how these factors interact with physical attractiveness to influence desirability. Undergraduates viewed photographs of the opposite sex individuals who were high or low in physical attractiveness, along with vignettes varying in humor production and receptivity. Participants rated physical attractiveness and desirability for long-term and short-term relationships. The main findings were that individuals desired partners who were high in humor production and receptivity, though the effects were particularly pronounced for women judging long-term relationships. Moreover, humor production was more important than receptivity for women’s ratings of male desirability. Notably, we also found that ratings of physical attractiveness were influenced by the humor conditions. These results are discussed in terms of the fitness indicator, interest indicator, and encryption hypotheses of the evolutionary functions of humor.

  14. More than Decadence - Johannes Jørgensen's early reception of Arthur Schopenhauer

    DEFF Research Database (Denmark)

    Nord, Johan Christian

    Fremmedsproglig forskningsformidling af hovedpunkterne i artiklen "En Poet og en Religionsstifter, med hvem jeg er enig i næsten alle Ting" Indledende betragtninger over Johannes Jørgensens Schopenhauer-reception.......Fremmedsproglig forskningsformidling af hovedpunkterne i artiklen "En Poet og en Religionsstifter, med hvem jeg er enig i næsten alle Ting" Indledende betragtninger over Johannes Jørgensens Schopenhauer-reception....

  15. Fully 3D tomographic reconstruction by Monte Carlo simulation of the system matrix in preclinical PET with iodine 124

    International Nuclear Information System (INIS)

    Moreau, Matthieu

    2014-01-01

    Immuno-PET imaging can be used to assess the pharmacokinetic in radioimmunotherapy. When using iodine-124, PET quantitative imaging is limited by physics-based degrading factors within the detection system and the object, such as the long positron range in water and the complex spectrum of gamma photons. The objective of this thesis was to develop a fully 3D tomographic reconstruction method (S(MC)2PET) using Monte Carlo simulations for estimating the system matrix, in the context of preclinical imaging with iodine-124. The Monte Carlo simulation platform GATE was used for that respect. Several complexities of system matrices were calculated, with at least a model of the PET system response function. Physics processes in the object was either neglected or taken into account using a precise or a simplified object description. The impact of modelling refinement and statistical variance related to the system matrix elements was evaluated on final reconstructed images. These studies showed that a high level of complexity did not always improve qualitative and quantitative results, owing to the high-variance of the associated system matrices. (author)

  16. Genome-Wide Association Study of Receptive Language Ability of 12-Year-Olds

    Science.gov (United States)

    Harlaar, Nicole; Meaburn, Emma L.; Hayiou-Thomas, Marianna E.; Davis, Oliver S. P.; Docherty, Sophia; Hanscombe, Ken B.; Haworth, Claire M. A.; Price, Thomas S.; Trzaskowski, Maciej; Dale, Philip S.; Plomin, Robert

    2014-01-01

    Purpose: Researchers have previously shown that individual differences in measures of receptive language ability at age 12 are highly heritable. In the current study, the authors attempted to identify some of the genes responsible for the heritability of receptive language ability using a "genome-wide association" approach. Method: The…

  17. The relation between receptive grammar and procedural, declarative, and working memory in specific language impairment.

    Science.gov (United States)

    Conti-Ramsden, Gina; Ullman, Michael T; Lum, Jarrad A G

    2015-01-01

    What memory systems underlie grammar in children, and do these differ between typically developing (TD) children and children with specific language impairment (SLI)? Whilst there is substantial evidence linking certain memory deficits to the language problems in children with SLI, few studies have investigated multiple memory systems simultaneously, examining not only possible memory deficits but also memory abilities that may play a compensatory role. This study examined the extent to which procedural, declarative, and working memory abilities predict receptive grammar in 45 primary school aged children with SLI (30 males, 15 females) and 46 TD children (30 males, 16 females), both on average 9;10 years of age. Regression analyses probed measures of all three memory systems simultaneously as potential predictors of receptive grammar. The model was significant, explaining 51.6% of the variance. There was a significant main effect of learning in procedural memory and a significant group × procedural learning interaction. Further investigation of the interaction revealed that procedural learning predicted grammar in TD but not in children with SLI. Indeed, procedural learning was the only predictor of grammar in TD. In contrast, only learning in declarative memory significantly predicted grammar in SLI. Thus, different memory systems are associated with receptive grammar abilities in children with SLI and their TD peers. This study is, to our knowledge, the first to demonstrate a significant group by memory system interaction in predicting grammar in children with SLI and their TD peers. In line with Ullman's Declarative/Procedural model of language and procedural deficit hypothesis of SLI, variability in understanding sentences of varying grammatical complexity appears to be associated with variability in procedural memory abilities in TD children, but with declarative memory, as an apparent compensatory mechanism, in children with SLI.

  18. Results of work of neurological clinic in first year of computer tomograph application

    Energy Technology Data Exchange (ETDEWEB)

    Volejnik, V; Nettl, S; Heger, L [Karlova Univ., Hradec Kralove (Czechoslovakia). Lekarska Fakulta

    1980-11-01

    The results are analyzed of one year's use of a computer tomograph (CT) by a department of neurology. Detailed comparisons with corresponding PEG and CT findings showed the accuracy of CT examinations in the descriptions of the width of the subarachnoid spaces and of the ventricular system. The advantages of CT are assessed from the medical, economic, and ethical points of view.

  19. Results of work of neurological clinic in first year of computer tomograph application

    International Nuclear Information System (INIS)

    Volejnik, V.; Nettl, S.; Heger, L.

    1980-01-01

    The results are analyzed of one year's use of a computer tomograph (CT) by a department of neurology. Detailed comparisons with corresponding PEG and CT findings showed the accuracy of CT examinations in the descriptions of the width of the subarachnoid spaces and of the ventricular system. The advantages of CT are assessed from the medical, economic, and ethical points of view. (author)

  20. Social Media-Based Civic Engagement Solutions for Dengue Prevention in Sri Lanka: Results of Receptivity Assessment

    Science.gov (United States)

    Lwin, May O.; Vijaykumar, Santosh; Foo, Schubert; Fernando, Owen Noel Newton; Lim, Gentatsu; Panchapakesan, Chitra; Wimalaratne, Prasad

    2016-01-01

    This article focuses on a novel social media-based system that addresses dengue prevention through an integration of three components: predictive surveillance, civic engagement and health education. The aim was to conduct a potential receptivity assessment of this system among smartphone users in the city of Colombo, the epicenter of the dengue…

  1. Mapping the receptivity of malaria risk to plan the future of control in Somalia.

    Science.gov (United States)

    Noor, Abdisalan Mohamed; Alegana, Victor Adagi; Patil, Anand Prabhakar; Moloney, Grainne; Borle, Mohammed; Yusuf, Fahmi; Amran, Jamal; Snow, Robert William

    2012-01-01

    To measure the receptive risks of malaria in Somalia and compare decisions on intervention scale-up based on this map and the more widely used contemporary risk maps. Cross-sectional community Plasmodium falciparum parasite rate (PfPR) data for the period 2007-2010 corrected to a standard age range of 2 to contemporary (2010) mean PfPR(2-10) and the maximum annual mean PfPR(2-10) (receptive) from the highest predicted PfPR(2-10) value over the study period as an estimate of receptivity. Randomly sampled communities in Somalia. Randomly sampled individuals of all ages. Cartographic descriptions of malaria receptivity and contemporary risks in Somalia at the district level. The contemporary annual PfPR(2-10) map estimated that all districts (n=74) and population (n=8.4 million) in Somalia were under hypoendemic transmission (≤10% PfPR(2-10)). Of these, 23% of the districts, home to 13% of the population, were under transmission of 10%-50% PfPR(2-10)) and the rest as hypoendemic. Compared with maps of receptive risks, contemporary maps of transmission mask disparities of malaria risk necessary to prioritise and sustain future control. As malaria risk declines across Africa, efforts must be invested in measuring receptivity for efficient control planning.

  2. Pressure spectra from single-snapshot tomographic PIV

    NARCIS (Netherlands)

    Schneiders, J.F.G.; Avallone, F.; Pröbsting, S.; Ragni, D.; Scarano, F.

    2018-01-01

    The power spectral density and coherence of temporal pressure fluctuations are obtained from low-repetition-rate tomographic PIV measurements. This is achieved by extension of recent single-snapshot pressure evaluation techniques based upon the Taylor’s hypothesis (TH) of frozen turbulence and

  3. The Social Nature of Argumentative Practices: The Philosophy of Argument and Audience Reception

    OpenAIRE

    Paula Olmos

    2018-01-01

    Abstract: This article reviews Christopher W. Tindale’s The Philosophy of Argument and Audience Reception (Cambridge, 2015). Résumé: Cet article est une critique de The Philosophy of Argument and Audience Reception (Cambridge, 2015) de Christopher W. Tindale.

  4. The receptiveness toward remotely supported myofeedback treatment

    NARCIS (Netherlands)

    Huis in 't Veld, M.H.A.; Voerman, Gerlienke; Hermens, Hermanus J.; Vollenbroek-Hutten, Miriam Marie Rosé

    Remotely supported myofeedback treatment (RSMT) is considered to be a potentially valuable alternative to the conventional myofeedback treatment, as it might increase efficiency of care. This study was aimed at examining the receptiveness of potential end users (patients and professionals) with

  5. Knockout mutations of insulin-like peptide genes enhance sexual receptivity in Drosophila virgin females.

    Science.gov (United States)

    Watanabe, Kazuki; Sakai, Takaomi

    2016-01-01

    In the fruitfly Drosophila melanogaster, females take the initiative to mate successfully because they decide whether to mate or not. However, little is known about the molecular and neuronal mechanisms regulating sexual receptivity in virgin females. Genetic tools available in Drosophila are useful for identifying molecules and neural circuits involved in the regulation of sexual receptivity. We previously demonstrated that insulin-producing cells (IPCs) in the female brain are critical to the regulation of female sexual receptivity. Ablation and inactivation of IPCs enhance female sexual receptivity, suggesting that neurosecretion from IPCs inhibits female sexual receptivity. IPCs produce and release insulin-like peptides (Ilps) that modulate various biological processes such as metabolism, growth, lifespan and behaviors. Here, we report a novel role of the Ilps in sexual behavior in Drosophila virgin females. Compared with wild-type females, females with knockout mutations of Ilps showed a high mating success rate toward wild-type males, whereas wild-type males courted wild-type and Ilp-knockout females to the same extent. Wild-type receptive females retard their movement during male courtship and this reduced female mobility allows males to copulate. Thus, it was anticipated that knockout mutations of Ilps would reduce general locomotion. However, the locomotor activity in Ilp-knockout females was significantly higher than that in wild-type females. Thus, our findings indicate that the high mating success rate in Ilp-knockout females is caused by their enhanced sexual receptivity, but not by improvement of their sex appeal or by general sluggishness.

  6. Receptivity of a high-speed boundary layer to temperature spottiness

    OpenAIRE

    Fedorov, A. V.; Ryzhov, A. A.; Soudakov, V. G.; Utyuzhnikov, S. V.

    2013-01-01

    Two-dimensional direct numerical simulation (DNS) of the receptivity of a flat-plate boundary layer to temperature spottiness in the Mach 6 free stream is carried out. The influence of spottiness parameters on the receptivity process is studied. It is shown that the temperature spots propagating near the upper boundary-layer edge generate mode F inside the boundary layer. Further downstream mode F is synchronized with unstable mode S (Mack second mode) and excites the latter via the inter-mod...

  7. Effective Strategies for Turning Receptive Vocabulary into Productive Vocabulary in EFL Context

    Science.gov (United States)

    Faraj, Avan Kamal Aziz

    2015-01-01

    Vocabulary acquisition has been a main concern of EFL English teachers and learners. There have been tons of research to examine the student's level of receptive vocabulary and productive vocabulary, but no research has conducted on how turning receptive vocabulary into productive vocabulary. This study has reported the impact of the teaching…

  8. Compressibility effects on the non-linear receptivity of boundary layers to dielectric barrier discharges

    Science.gov (United States)

    Denison, Marie F. C.

    The reduction of drag and aerodynamic heating caused by boundary layer transition is of central interest for the development of hypersonic vehicles. Receptivity to flow perturbation in the form of Tollmien-Schlichting (TS) wave growth often determines the first stage of the transition process, which can be delayed by depositing specific excitations into the boundary layer. Weakly ionized Dielectric Barrier Discharge (DBD) actuators are being investigated as possible sources of such excitations, but little is known today about their interaction with high-speed flows. In this framework, the first part of the thesis is dedicated to a receptivity study of laminar compressible boundary layers over a flat plate by linear stability analysis following an adjoint operator formulation, under DBD representative excitations assumed independent of flow conditions. The second part of the work concentrates on the development of a coupled plasma-Navier and Stokes solver targeted at the study of supersonic flow and compressibility effects on DBD forcing and non-parallel receptivity. The linear receptivity study of quasi-parallel compressible flows reveals several interesting features such as a significant shift of the region of maximum receptivity deeper into the flow at high Mach number and strong wave amplitude reduction compared to incompressible flows. The response to DBD relevant excitation distributions and to variations of the base flow conditions and system length scales follows these trends. Observed absolute amplitude changes and relative sensitivity modifications between source types are related to the evolution of the offset between forcing peak profile and relevant adjoint mode maximum. The analysis highlights the crucial importance of designing and placing the actuator in a way that matches its force field to the position of maximum boundary layer receptivity for the specific flow conditions of interest. In order to address the broad time and length scale spectrum

  9. Tomographic Particle Image Velocimetry Using Colored Shadow Imaging

    KAUST Repository

    Alarfaj, Meshal K.

    2016-02-01

    Tomographic Particle Image Velocimetry Using Colored Shadow Imaging by Meshal K Alarfaj, Master of Science King Abdullah University of Science & Technology, 2015 Tomographic Particle image velocimetry (PIV) is a recent PIV method capable of reconstructing the full 3D velocity field of complex flows, within a 3-D volume. For nearly the last decade, it has become the most powerful tool for study of turbulent velocity fields and promises great advancements in the study of fluid mechanics. Among the early published studies, a good number of researches have suggested enhancements and optimizations of different aspects of this technique to improve the effectiveness. One major aspect, which is the core of the present work, is related to reducing the cost of the Tomographic PIV setup. In this thesis, we attempt to reduce this cost by using an experimental setup exploiting 4 commercial digital still cameras in combination with low-cost Light emitting diodes (LEDs). We use two different colors to distinguish the two light pulses. By using colored shadows with red and green LEDs, we can identify the particle locations within the measurement volume, at the two different times, thereby allowing calculation of the velocities. The present work tests this technique on the flows patterns of a jet ejected from a tube in a water tank. Results from the images processing are presented and challenges discussed.

  10. Computed tomographic findings of traumatic intracranial lesions

    International Nuclear Information System (INIS)

    Jeong, Seong Wook; Kim, Il Young; Lee, Byung Ho; Kim, Ki Jeoung; Yoon, Il Gyu

    1985-01-01

    Traumatic intracranial lesion has been one of the most frequent and serious problem in neurosurgical pathology. Computed tomography made it possible to get prompt diagnosis and surgical intervention of intracranial lesions by its safety, fastness and accuracy. Computed tomographic scan was carried out on 1309 cases at Soonchunhyang Chunan Hospital for 15 months from October 1983 to December 1984. We have reviewed the computed tomographic scans of 264 patients which showed traumatic intracranial lesion. The result were as follows: 1. Head trauma was the most frequent diagnosed disease using computed tomographic scans (57.8%) and among 264 cases the most frequent mode of injury was traffic accident (73.9%). 2. Skull fracture was accompanied in frequency of 69.7% and it was detected in CT in 38.6%: depression fracture was more easily detected in 81%. 3. Conutercoup lesion (9.5%) was usually accompanied with temporal and occipital fracture, and it appeared in lower incidence among pediatric group. 4. Intracranial lesions of all 264 cases were generalized cerebral swelling (24.6%), subdural hematoma (22.3%), epidural hematoma (20.8%), intracerebral hematoma (6.1%), and subarachnoid hemorrhage (3.0%). 5. The shape of hematoma was usually biconvex (92.7%) in acute epidural hematoma and cresentic (100%) in acute subdural hematoma, but the most chronic the case became, they showed planoconvex and bicconvex shapes. 6. Extra-axial hematoma was getting decreased in density as time gone by. 7. Hematoma density was not in direct proportion to serum hemoglobin level as single factor

  11. Computed tomographic findings of traumatic intracranial lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Seong Wook; Kim, Il Young; Lee, Byung Ho; Kim, Ki Jeoung; Yoon, Il Gyu [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1985-10-15

    Traumatic intracranial lesion has been one of the most frequent and serious problem in neurosurgical pathology. Computed tomography made it possible to get prompt diagnosis and surgical intervention of intracranial lesions by its safety, fastness and accuracy. Computed tomographic scan was carried out on 1309 cases at Soonchunhyang Chunan Hospital for 15 months from October 1983 to December 1984. We have reviewed the computed tomographic scans of 264 patients which showed traumatic intracranial lesion. The result were as follows: 1. Head trauma was the most frequent diagnosed disease using computed tomographic scans (57.8%) and among 264 cases the most frequent mode of injury was traffic accident (73.9%). 2. Skull fracture was accompanied in frequency of 69.7% and it was detected in CT in 38.6%: depression fracture was more easily detected in 81%. 3. Conutercoup lesion (9.5%) was usually accompanied with temporal and occipital fracture, and it appeared in lower incidence among pediatric group. 4. Intracranial lesions of all 264 cases were generalized cerebral swelling (24.6%), subdural hematoma (22.3%), epidural hematoma (20.8%), intracerebral hematoma (6.1%), and subarachnoid hemorrhage (3.0%). 5. The shape of hematoma was usually biconvex (92.7%) in acute epidural hematoma and cresentic (100%) in acute subdural hematoma, but the most chronic the case became, they showed planoconvex and bicconvex shapes. 6. Extra-axial hematoma was getting decreased in density as time gone by. 7. Hematoma density was not in direct proportion to serum hemoglobin level as single factor.

  12. Computerized tomographic diagnosis of basal skull fracture

    International Nuclear Information System (INIS)

    Tanaka, Tokutaro; Shimoyama, Ichiro; Endoh, Mitsutoshi; Ninchoji, Toshiaki; Uemura, Kenichi.

    1984-01-01

    The diagnosis of basal skull fractures used to be difficult, particularly on the basis of routine skull roentgenography alone. We have now examined the diagnostic value of conventional computerized tomography in basal skull fractures. We studied 82 cases clinically diagnosed as basal skull fractures. We examined them based on at least one of the following computerized tomographic criteria for basal skull fractures: 1) fracture line(s), 2) intracranial air, 3) fluid in the paranasal sinuses, and 4) fluid in the middle ear, including the mastoid air cells. The signs of the fracture line and of the intracranial air are definite indications of basal skull fracture, but the signs of fluid in the paranasal sinuses and/or in the middle ear are not definite. When combined, however, with such other clinical signs as black eye, Battle's sign, CSF leakage, CSF findings, and profuse nasal or ear bleeding, the diagnosis is more reliable. Seventy cases (85.4%) in this series had basal skull fractures according to our computerized tomographic criteria. Among them , 26 cases (31.7%) were diagnosed with fracture lines, 17 cases (20.7%) with intracranial air, 16 cases (19.5%) with fluid in the paranasal sinuses, 10 cases (12.2%) with fluid in the middle ear, and one case (1.2%) with fluid in both. Twelve cases (14.6%) of the 82 cases clinically diagnosed as basal skull fractures could not have been diagnosed on our computerized tomographic criteria alone. We diagnosed them because of CSF leakage, CSF findings, surgical findings, etc. (author)

  13. A study of the decoding of multiple pinhole coded aperture RI tomographic images

    International Nuclear Information System (INIS)

    Hasegawa, Takeo; Kobayashi, Akitoshi; Nishiyama, Yutaka; Akagi, Kiyoshi; Uehata, Hiroshi

    1981-01-01

    In order to obtain a radioisotope (RI) tomographic image, there are various, methods, including the RCT method, Time Modulate method, and Multiple Pinhole Coded Aperture (MPCA) method and others. The MPCA method has several advantages. Using the MPCA method, there is no need to move either the detector or the patient, Furthermore, the generally used γ-camera may be used without any alterations. Due to certain problems in reconstructing the tomographic image, the use of the MPCA method in clinical practice is limited to representation of small organs (e.g. heart) using the 7-Pinhole collimator. This research presents an experimental approach to overcome the problems in reconstruction of tomographic images of large organs (organs other than the heart, such as the brain, liver, lung etc.) by introducing a reconstruction algorithm and correction software into the MPCA method. There are 2 main problems in MPCA image reconstruction: (1) Due to the rounding-off procedure, there is both point omission and shifting of point coordinates. (2) The central portion is characterized by high-counts. Both of these problems were solved by incorporating a reconstruction algorithm and a correction function. The resultant corrected tomographic image was processed using a filter derived from subjecting a PSF to a Fourier transform. Thus, it has become possible to obtain a high-quality tomographic image of large organs for clinical use. (author)

  14. Computed tomographic appearances of sternocostoclavicular hyperostosis

    Energy Technology Data Exchange (ETDEWEB)

    Chigira, Masaki; Shimizu, Toru (Gunma Univ. (Japan). Dept. of Orthopaedic Surgery)

    1989-08-01

    Computed tomographical analysis of sternocostoclavicular hyperostosis was performed in 27 patients. In the earliest stage hyperostosis occurred around the cartilaginous portion of the first ribs. The sternoclavicular joint space was preserved even in the late stage III of the disorder. It is also suggested that perichondritis and periostitis play important roles in the etiology of this disorder. (orig./GDG).

  15. Computed tomographic appearances of sternocostoclavicular hyperostosis

    International Nuclear Information System (INIS)

    Chigira, Masaki; Shimizu, Toru

    1989-01-01

    Computed tomographical analysis of sternocostoclavicular hyperostosis was performed in 27 patients. In the earliest stage hyperostosis occurred around the cartilaginous portion of the first ribs. The sternoclavicular joint space was preserved even in the late stage III of the disorder. It is also suggested that perichondritis and periostitis play important roles in the etiology of this disorder. (orig./GDG)

  16. Segmentation-DrivenTomographic Reconstruction

    DEFF Research Database (Denmark)

    Kongskov, Rasmus Dalgas

    such that the segmentation subsequently can be carried out by use of a simple segmentation method, for instance just a thresholding method. We tested the advantages of going from a two-stage reconstruction method to a one stage segmentation-driven reconstruction method for the phase contrast tomography reconstruction......The tomographic reconstruction problem is concerned with creating a model of the interior of an object from some measured data, typically projections of the object. After reconstructing an object it is often desired to segment it, either automatically or manually. For computed tomography (CT...

  17. Comparative validation of the radiographic and tomographic measurement of patellar height

    Directory of Open Access Journals (Sweden)

    Marco Antonio Schueda

    2013-09-01

    Full Text Available OBJECTIVE: To evaluate and validate the radiographic measurement of patellar height with computerized tomography scans. METHODS: Measured the patellar height through the lateral radiographic image supported by one foot and sagittal tomographic view of the knee in extension, flexion of 20°, and quadriceps contraction of 40 patients (80 knees, asymptomatic and no history of knee injuries using Insall-Salvati index. There were 20 adult females and 20 adult males. RESULTS: The height patellar index was higher in women of all images taken, in proportion. There was no statistical difference of patellar height index between the radiographics and tomographics images. CONCLUSION: The Insall-Salvati index in females was higher in all cases evaluated. Furthermore, it is possible to measure the patellar height index during tomographic study without distorting the results obtained, using to define the presence of patella alta or patella baja.

  18. Quantum probability measures and tomographic probability densities

    NARCIS (Netherlands)

    Amosov, GG; Man'ko, [No Value

    2004-01-01

    Using a simple relation of the Dirac delta-function to generalized the theta-function, the relationship between the tomographic probability approach and the quantum probability measure approach with the description of quantum states is discussed. The quantum state tomogram expressed in terms of the

  19. Technological Development and Its Impact on Student Reception of a Campus Radio

    Science.gov (United States)

    Mohamed, Shafizan; Wok, Saodah; Lahabou, Mahaman

    2018-01-01

    In 2011, a study was conducted to look at students' reception of IIUM.FM, a newly launched online campus radio. Using the Technological Acceptance Model (TAM), the study found that factors such as perceived ease of use, perceived usefulness, and attitude highly influenced audience reception of the online radio. In 2016, a corresponding study,…

  20. Achievement report for fiscal 1999 on research and development of technologies for medical welfare equipment. Intravascular 3D ultrasound imaging system for supporting less invasive diagnosis; 1999 nendo iryo fukushi kiki gijutsu kenkyu kaihatsu seika hokokusho. Shindan shiengata choonpa kekkannai sanjigen imaging system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-05-01

    An ultrasonic probe with its point fine is navigated in blood vessels and body cavities by 3-dimensional ultrasonic signals (with the oscillator driven by transmission from a catheter for position detection) for the acquisition of accurate 3-dimensional ultrasound images in a less invasive way. The transmission and reception circuits are provided with circuits for ultrasound tomographic images and for navigation. Trial units are fabricated and tested for transmission waveform and reception performance. The scanner is rotated for the acquisition of intravascular 3-dimensional radial images. The scanner rotating rate is set at 30 rps for the scanner performance not to be affected by heartbeat and the rate is controlled by the observation unit which changes voltage for the control. The 3-dimensional display software program, thanks to the navigation function of the external probe, detects the external probe position relative to the small-diameter probe for the construction of accurate 3-dimensional images. Specifications for a total system, which makes full use of a navigation function, are compiled, consisting of a small-diameter probe and a body surface real-time 3-dimensional display. (NEDO)

  1. The Receptive-Expressive Gap in the Vocabulary of Young Second-Language Learners: Robustness and Possible Mechanisms

    Science.gov (United States)

    Gibson, Todd A.; Oller, D. Kimbrough; Jarmulowicz, Linda; Ethington, Corinna A.

    2012-01-01

    Adults and children learning a second language show difficulty accessing expressive vocabulary that appears accessible receptively in their first language (L1). We call this discrepancy the receptive-expressive gap. Kindergarten Spanish (L1)-English (L2) sequential bilinguals were given standardized tests of receptive and expressive vocabulary in…

  2. Review of foreign reception of Jovan Babić’s works

    Directory of Open Access Journals (Sweden)

    Dobrijević Aleksandar

    2015-01-01

    Full Text Available In this paper, the author discusses foreign reception of Jovan Babić’s works, which turns out to be very much alive and diverse. More precisely, the author limits himself to a short and very partial review of reception of only two Babić’s texts that, so far, attracted the most attention. [Projekat Ministarstva nauke Republike Srbije, br. 43007 i br. 179041

  3. Computed tomographic appearances of cherubism

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, S D; Boccardi, A; Mela, F; Romagnoli, R

    1987-01-01

    The computed tomographic (CT) aspects of six cases of cherubism are described. Through its optimal representation of the lesions, CT enabled certain characteristics of this disease to be substantiated, namely, limitation of the process to the bones of the jaw and primarily superficial development of the mandibular lesions, coupled with an unusual mandibular condylar impairment. Moreover, the composition of this series permitted investigation of the condition in its several stages of progression.

  4. Tomographic reconstruction of atmospheric volumes from infrared limb-imager measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ungermann, Joern

    2011-08-12

    State-of-the art nadir and limb-sounders, but also in situ measurements, do not offer the capability to highly resolve the atmosphere in all three dimensions. This leaves an observational gap with respect to small-scale structures that arise frequently in the atmosphere and that still lack a quantitative understanding. For instance, filaments and tropopause folds in the upper troposphere and lower stratosphere (UTLS) are crucial for its composition and variability. One way to achieve a highly resolved three-dimensional (3-D) picture of the atmosphere is the tomographic evaluation of limb-imager measurements. This thesis presents a methodology for the tomographic reconstruction of atmospheric constituents. To be able to deal with the large increase of observations and unknowns compared to conventional retrievals, great care is taken to reduce memory consumption and processing time. This method is used to evaluate the performance of two upcoming infrared limb-imager instruments and to prepare their missions. The first examined instrument is the infrared limb-imager on board of PREMIER (Process Exploration through Measurements of Infrared and millimetrewave Emitted Radiation), one of three remaining candidates for ESA's 7th Earth Explorer mission. Scientific goals of PREMIER are, among others, the examination of gravity waves and the quantification of processes controlling atmospheric composition in the UTLS, a region of particular importance for climate change. Simulations based on the performance requirements of this instrument deliver a vertical resolution that is slightly better than its vertical field-of-view (about 0.75 km) and a horizontal resolution of {approx}25km x 70 km. Non-linear end-to-end simulations for various gravity wave patterns demonstrate that the high 3-D resolution of PREMIER considerably extends the range of detectable gravity waves in terms of horizontal and vertical wavelength compared to previous observations. The second examined

  5. Tomographic reconstruction of atmospheric volumes from infrared limb-imager measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ungermann, Joern

    2011-08-12

    State-of-the art nadir and limb-sounders, but also in situ measurements, do not offer the capability to highly resolve the atmosphere in all three dimensions. This leaves an observational gap with respect to small-scale structures that arise frequently in the atmosphere and that still lack a quantitative understanding. For instance, filaments and tropopause folds in the upper troposphere and lower stratosphere (UTLS) are crucial for its composition and variability. One way to achieve a highly resolved three-dimensional (3-D) picture of the atmosphere is the tomographic evaluation of limb-imager measurements. This thesis presents a methodology for the tomographic reconstruction of atmospheric constituents. To be able to deal with the large increase of observations and unknowns compared to conventional retrievals, great care is taken to reduce memory consumption and processing time. This method is used to evaluate the performance of two upcoming infrared limb-imager instruments and to prepare their missions. The first examined instrument is the infrared limb-imager on board of PREMIER (Process Exploration through Measurements of Infrared and millimetrewave Emitted Radiation), one of three remaining candidates for ESA's 7th Earth Explorer mission. Scientific goals of PREMIER are, among others, the examination of gravity waves and the quantification of processes controlling atmospheric composition in the UTLS, a region of particular importance for climate change. Simulations based on the performance requirements of this instrument deliver a vertical resolution that is slightly better than its vertical field-of-view (about 0.75 km) and a horizontal resolution of {approx}25km x 70 km. Non-linear end-to-end simulations for various gravity wave patterns demonstrate that the high 3-D resolution of PREMIER considerably extends the range of detectable gravity waves in terms of horizontal and vertical wavelength compared to previous observations. The second examined instrument

  6. Electronics for the Donner 600-Crystal Positron Tomograph

    International Nuclear Information System (INIS)

    Cahoon, J.L.; Huesman, R.H.; Derenzo, S.E.; Geyer, A.B.; Uber, D.C.; Turko, B.T.; Budinger, T.F.

    1985-10-01

    The data acquisition system, designed for the Donner 600-Crystal Positron Tomograph, is described. Coincidence timing resolution of less than five nanoseconds full width at half maximum and data rates in excess of one million events per second are achieved by using high-speed emitter coupled logic circuits, first-in first-out memory to derandomize data flow, and parallel architecture to increase throughput. These data rates allow the acquisition of adequate transmission data in a reasonable amount of time. Good timing resolution minimizes accidental coincidences and permits data rates greater than 100,000 image-forming events per second for high-speed dynamic emission tomography. Additional scatter and accidental rejection are accomplished for transmission data by using an orbiting source and a look-up table for valid events. Calibration of this complex electronic system is performed automatically under computer control. 4 refs., 5 figs

  7. Emission computed tomograph

    International Nuclear Information System (INIS)

    Hirose, Y.; Kanno, I.; Koga, K.; Miura, S.; Uemura, K.

    1981-01-01

    Emission computed tomograph wherein a pluralty of detectors surround an object to be examined so as to detect x- or gamma radiation emitted by said object. In front of each of said detectors there is provided a collimator which comprises a pair of main plates and a subsidiary plate interposed therebetween. The plates are made of a material capable of blocking penetration of the radiation therethrough and so supported as to be swingable over an angle sufficient to cover the whole of said object. The plates of all the collimators are simultaneously swung to the same side and at the same angular speed thereby to change the direction of incidence of said radiation on each of said detectors

  8. Case Report: Unusual computed tomographic features of ...

    African Journals Online (AJOL)

    A case report of a 57-year old woman who presented with signs and symptoms of intracranial mass. Computed tomographic (CT) and clinical features were unusual and suggestive of a parasaggital Meningioma. However an accurate diagnosis of a tuberculoma was made at surgery and histopathological examination.

  9. Tobacco marketing receptivity and other tobacco product use among young adult bar patrons

    Science.gov (United States)

    Thrul, Johannes; Lisha, Nadra E.; Ling, Pamela M.

    2016-01-01

    Purpose Use of other tobacco products (smokeless tobacco, hookah, cigarillo, e-cigarettes) is increasing, particularly among young adults, and there are few regulations on marketing for these products. We examined the associations between tobacco marketing receptivity and other tobacco product (OTP) use among young adult bar patrons (aged 18-26 years). Methods Time-location sampling was used to collect cross-sectional surveys from 7,540 young adult bar patrons from January 2012 through March of 2014. Multivariable logistic regression analyses in 2015 examined if tobacco marketing receptivity was associated (1) with current (past 30 day) OTP use controlling for demographic factors, and (2) with dual/poly use among current cigarette smokers (n=3,045), controlling for demographics and nicotine dependence. Results Among the entire sample of young adult bar patrons (Mage=23.7, SD=1.8; 48.1% female), marketing receptivity was consistently associated with current use of all OTP including smokeless tobacco (adjusted odds ratio [AOR]= 2.49, 95% confidence interval [CI] 1.90-3.27, pmarketing receptivity was significantly associated with use of smokeless tobacco (AOR=1.44, 95% CI 1.05-1.98, pmarketing receptivity. Efforts to limit tobacco marketing should address OTP in addition to cigarettes. PMID:27707516

  10. Speech recognition employing biologically plausible receptive fields

    DEFF Research Database (Denmark)

    Fereczkowski, Michal; Bothe, Hans-Heinrich

    2011-01-01

    spectro-temporal receptive fields to auditory spectrogram input, motivated by the auditory pathway of humans, and ii) the adaptation or learning algorithms involved are biologically inspired. This is in contrast to state-of-the-art combinations of Mel-frequency cepstral coefficients and Hidden Markov...

  11. Ableism and the Reception of Improvised Soundsinging

    NARCIS (Netherlands)

    Tonelli, Christopher

    2016-01-01

    Soundsinging is one name for the practice of making music using an idiosyncratic palette of vocal and non-vocal oral techniques. This paper is concerned with the reception of soundsinging and, more specifically, with listeners whose reactions to soundsinging involve attempts to contain the practice.

  12. The reception of relativity in the Netherlands

    NARCIS (Netherlands)

    van Besouw, J.; van Dongen, J.A.E.F.

    2013-01-01

    This article reviews the early academic and public reception of Albert Einstein's theory of relativity in the Netherlands, particularly after Arthur Eddington's eclipse experiments of 1919. Initially, not much attention was given to relativity, as it did not seem an improvement over Hendrik A.

  13. Endometrial Receptivity Profile in Patients with Premature Progesterone Elevation on the Day of hCG Administration

    Directory of Open Access Journals (Sweden)

    Delphine Haouzi

    2014-01-01

    Full Text Available The impact of a premature elevation of serum progesterone level, the day of hCG administration in patients under controlled ovarian stimulation during IVF procedure, on human endometrial receptivity is still debated. In the present study, we investigated the endometrial gene expression profile shifts during the prereceptive and receptive secretory stage in patients with normal and elevated serum progesterone level on the day of hCG administration in fifteen patients under stimulated cycles. Then, specific biomarkers of endometrial receptivity in these two groups of patients were tested. Endometrial biopsies were performed on oocyte retrieval day and on day 3 of embryo transfer, respectively, for each patient. Samples were analysed using DNA microarrays and qRT-PCR. The endometrial gene expression shift from the prereceptive to the receptive stage was altered in patients with high serum progesterone level (>1.5 ng/mL on hCG day, suggesting accelerated endometrial maturation during the periovulation period. This was confirmed by the functional annotation of the differentially expressed genes as it showed downregulation of cell cycle-related genes. Conversely, the profile of endometrial receptivity was comparable in both groups. Premature progesterone rise alters the endometrial gene expression shift between the prereceptive and the receptive stage but does not affect endometrial receptivity.

  14. Aesthetic-Receptive and Critical-Creative in Appreciative Reading

    Directory of Open Access Journals (Sweden)

    Titin Setiartin

    2017-10-01

    Full Text Available Reading is a process of aesthetically appreciative receptive to emphasize critical-creative reading activities. Metacognitively students understand, address any and explore the idea of the author in the text. Students responded, criticize, and evaluate the author's ideas in the text. At this stage, students can construct their post read text into other forms (new text. The aim of this strategy equips students to understand the meaning of the story, explore ideas, responding critically, and creatively pouring backstory idea. Reading strategies aesthetically-critical-creative receptive grabbed cognitive, effective, and psychomotor toward literacy critical reading and creative writing. Read appreciative included into the activities of reading comprehension. This activity involves the sensitivity and ability to process aesthetically-receptive reading and critical-creative. Readers imagination roam the author to obtain meaningful understanding and experience of reading. Some models of reading comprehension proposed experts covering the steps before reading, when reading, and after reading. At that stage to enable students after reading thinking abilities. Activities that can be done at this stage, for example, examine the back story, retell, make drawings, diagrams, or maps the concept of reading, as well as making a road map that describes the event. Other activities that can be done is to transform our student's text stories through reinforcement form illustrated stories into comic book form, for example (transliteration.

  15. Application of the FDK algorithm for multi-slice tomographic image reconstruction; Aplicacao do algoritmo FDK para a reconstrucao de imagens tomograficas multicortes

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Paulo Roberto, E-mail: pcosta@if.usp.b [Universidade de Sao Paulo (IFUSP), SP (Brazil). Inst. de Fisica. Dept. de Fisica Nuclear; Araujo, Ericky Caldas de Almeida [Fine Image Technology, Sao Paulo, SP (Brazil)

    2010-08-15

    This work consisted on the study and application of the FDK (Feldkamp- Davis-Kress) algorithm for tomographic image reconstruction using cone-beam geometry, resulting on the implementation of an adapted multi-slice computed tomography system. For the acquisition of the projections, a rotating platform coupled to a goniometer, an X-ray equipment and a digital image detector charge-coupled device type were used. The FDK algorithm was implemented on a computer with a Pentium{sup R} XEON{sup TM} 3.0 processor, which was used for the reconstruction process. Initially, the original FDK algorithm was applied considering only the ideal physical conditions in the measurement process. Then some artifacts corrections related to the projections measurement process were incorporated. The implemented MSCT system was calibrated. A specially designed and manufactured object with a known linear attenuation coefficient distribution ({mu}(r)) was used for this purpose. Finally, the implemented MSCT system was used for multi-slice tomographic reconstruction of an inhomogeneous object, whose distribution {mu}(r) was unknown. Some aspects of the reconstructed images were analyzed to assess the robustness and reproducibility of the system. During the system calibration, a linear relationship between CT number and linear attenuation coefficients of materials was verified, which validate the application of the implemented multi-slice tomographic system for the characterization of linear attenuation coefficients of distinct several objects. (author)

  16. Time-resolved tomographic images of a relativistic electron beam

    International Nuclear Information System (INIS)

    Koehler, H.A.; Jacoby, B.A.; Nelson, M.

    1984-07-01

    We obtained a sequential series of time-resolved tomographic two-dimensional images of a 4.5-MeV, 6-kA, 30-ns electron beam. Three linear fiber-optic arrays of 30 or 60 fibers each were positioned around the beam axis at 0 0 , 61 0 , and 117 0 . The beam interacting with nitrogen at 20 Torr emitted light that was focused onto the fiber arrays and transmitted to a streak camera where the data were recorded on film. The film was digitized, and two-dimensional images were reconstructed using the maximum-entropy tomographic technique. These images were then combined to produce an ultra-high-speed movie of the electron-beam pulse

  17. Application of biorthogonal eigenfunction system for extraction of Tollmien-Schlichting waves in acoustic receptivity simulations

    OpenAIRE

    Shahriari, Nima; Hanifi, Ardeshir; Henningson, Dan S.

    2016-01-01

    Acoustic receptivity of a two-dimensional boundary layer on a flat plate with elliptic leading edge is studied through direct numerical simulation (DNS). Sound waves are modelled by a uniform oscillation of freestream boundaries in time which results to an infinite-wavelength acoustic wave. Acoustic disturbances interact with strong streamwise gradients at the leading edge or surface non- homogeneities and create Tollmien-Schlichting (TS) waves inside the boundary layer. Measuring amplitude o...

  18. Development of a new comprehensive and reliable endometrial receptivity map (ER Map/ER Grade) based on RT-qPCR gene expression analysis.

    Science.gov (United States)

    Enciso, M; Carrascosa, J P; Sarasa, J; Martínez-Ortiz, P A; Munné, S; Horcajadas, J A; Aizpurua, J

    2018-02-01

    Is it possible to determine the receptivity status of an endometrium by combined quantitative reverse transcription PCR (RT-qPCR) expression analysis of genes involved in endometrial proliferation and immunity? The new ER Map®/ER Grade® test can predict endometrial receptivity status by RT-qPCR using a new panel of genes involved in endometrial proliferation and the maternal immune response associated to embryonic implantation. The human endometrium reaches a receptive status adequate for embryonic implantation around Days 19-21 of the menstrual cycle. During this period, known as the window of implantation (WOI), the endometrium shows a specific gene expression profile suitable for endometrial function evaluation. The number of molecular diagnostic tools currently available to characterize this process is very limited. In this study, a new system for human endometrial receptivity evaluation was optimized and presented for the first time. ER Map®/ER Grade® validation was achieved on 312 endometrial samples including fertile women and patients undergoing fertility treatment between July 2014 and March 2016. Expression analyses of 184 genes involved in endometrial receptivity and immune response were performed. Samples were additionally tested with an independent endometrial receptivity test. A total of 96 fertile women and 120 assisted reproduction treatment (ART) patients participated in the study. Endometrial biopsy samples were obtained at LH + 2 and LH + 7 days in fertile subjects in a natural cycle and at the window of implantation (WOI) in patients in a hormone-replacement therapy (HRT) cycle. Total RNA was purified, quality-checked and reverse-transcribed. Gene expression was quantified by high-throughput RT-qPCR and statistically analyzed. Informative genes were selected and used to classify samples into four different groups of endometrial receptivity status. Significantly different gene expression levels were found in 85 out of 184 selected genes when

  19. An introduction to the tomographic picture of quantum mechanics

    International Nuclear Information System (INIS)

    Ibort, A; Man'ko, V I; Marmo, G; Simoni, A; Ventriglia, F

    2009-01-01

    Starting from the famous Pauli problem on the possibility of associating quantum states with probabilities, the formulation of quantum mechanics in which quantum states are described by fair probability distributions (tomograms, i.e. tomographic probabilities) is reviewed in a pedagogical style. The relation between the quantum state description and the classical state description is elucidated. The difference between those sets of tomograms is described by inequalities equivalent to a complete set of uncertainty relations for the quantum domain and to non-negativity of probability density on phase space in the classical domain. The intersection of such sets is studied. The mathematical mechanism that allows us to construct different kinds of tomographic probabilities like symplectic tomograms, spin tomograms, photon number tomograms, etc is clarified and a connection with abstract Hilbert space properties is established. The superposition rule and uncertainty relations in terms of probabilities as well as quantum basic equations like quantum evolution and energy spectra equations are given in an explicit form. A method to check experimentally the uncertainty relations is suggested using optical tomograms. Entanglement phenomena and the connection with semigroups acting on simplexes are studied in detail for spin states in the case of two-qubits. The star-product formalism is associated with the tomographic probability formulation of quantum mechanics.

  20. Chamber of Commerce reception for Dr. Lucas

    Science.gov (United States)

    1986-01-01

    Dr. William R. Lucas, Marshall's fourth Center Director (1974-1986), delivers a speech in front of a picture of the lunar landscape with Earth looming in the background while attending a Huntsville Chamber of Commerce reception honoring his achievements as Director of Marshall Space Flight Center (MSFC).

  1. Reception Shop Special Stand

    CERN Multimedia

    Education and Technology Transfer Unit/ETT-EC

    2004-01-01

    Friday 15.10.2004 CERN 50th Anniversary articles will be sold in the Main Building, ground floor on Friday 15th October from 10h00 to 16h00. T-shirt, (S, M, L, XL) 20.- K-way (M, L, XL) 20.- Silk tie (2 models) 30.- Einstein tie 45.- Umbrella 20.- Caran d'Ache pen 5.- 50th Anniversary Pen 5.- Kit of Cartoon Album & Crayons 10.- All the articles are also available at the Reception Shop in Building 33 from Monday to Saturday between 08.30 and 17.00 hrs. Education and Technology Transfer Unit/ETT-EC

  2. Teaching Receptive Naming of Chinese Characters to Children with Autism by Incorporating Echolalia.

    Science.gov (United States)

    Leung, Jin-Pang; Wu, Kit-I

    1997-01-01

    The facilitative effect of incorporating echolalia on teaching receptive naming of Chinese characters to four Hong Kong children (ages 8-10) with autism was assessed. Results from two experiments indicated echolalia was the active component contributing to the successful acquisition and maintenance of receptive naming of Chinese characters.…

  3. An Examination of College Students' Receptiveness to Alcohol-Related Information and Advice

    Science.gov (United States)

    Leahy, Matthew M.; Jouriles, Ernest N.; Walters, Scott T.

    2013-01-01

    This project examined the reliability and validity of a newly developed measure of college students' receptiveness to alcohol related information and advice. Participants were 116 college students who reported having consumed alcohol at some point in their lifetime. Participants completed a measure of receptiveness to alcohol-related…

  4. Hybrid Photoacoustic/Ultrasound Tomograph for Real-Time Finger Imaging.

    Science.gov (United States)

    Oeri, Milan; Bost, Wolfgang; Sénégond, Nicolas; Tretbar, Steffen; Fournelle, Marc

    2017-10-01

    We report a target-enclosing, hybrid tomograph with a total of 768 elements based on capacitive micromachined ultrasound transducer technology and providing fast, high-resolution 2-D/3-D photoacoustic and ultrasound tomography tailored to finger imaging. A freely programmable ultrasound beamforming platform sampling data at 80 MHz was developed to realize plane wave transmission under multiple angles. A multiplexing unit enables the connection and control of a large number of elements. Fast image reconstruction is provided by GPU processing. The tomograph is composed of four independent and fully automated movable arc-shaped transducers, allowing imaging of all three finger joints. The system benefits from photoacoustics, yielding high optical contrast and enabling visualization of finger vascularization, and ultrasound provides morphologic information on joints and surrounding tissue. A diode-pumped, Q-switched Nd:YAG laser and an optical parametric oscillator are used to broaden the spectrum of emitted wavelengths to provide multispectral imaging. Custom-made optical fiber bundles enable illumination of the region of interest in the plane of acoustic detection. Precision in positioning of the probe in motion is ensured by use of a motor-driven guide slide. The current position of the probe is encoded by the stage and used to relate ultrasound and photoacoustic signals to the corresponding region of interest of the suspicious finger joint. The system is characterized in phantoms and a healthy human finger in vivo. The results obtained promise to provide new opportunities in finger diagnostics and establish photoacoustic/ultrasound-tomography in medical routine. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. Visual servoing in medical robotics: a survey. Part II: tomographic imaging modalities--techniques and applications.

    Science.gov (United States)

    Azizian, Mahdi; Najmaei, Nima; Khoshnam, Mahta; Patel, Rajni

    2015-03-01

    Intraoperative application of tomographic imaging techniques provides a means of visual servoing for objects beneath the surface of organs. The focus of this survey is on therapeutic and diagnostic medical applications where tomographic imaging is used in visual servoing. To this end, a comprehensive search of the electronic databases was completed for the period 2000-2013. Existing techniques and products are categorized and studied, based on the imaging modality and their medical applications. This part complements Part I of the survey, which covers visual servoing techniques using endoscopic imaging and direct vision. The main challenges in using visual servoing based on tomographic images have been identified. 'Supervised automation of medical robotics' is found to be a major trend in this field and ultrasound is the most commonly used tomographic modality for visual servoing. Copyright © 2014 John Wiley & Sons, Ltd.

  6. Computed tomographic study of 50 patients with hypodense hepatic injuries in childhood

    International Nuclear Information System (INIS)

    Pereira, Ines Minniti Rodrigues; Alvares, Beatriz Regina; Baracat, Jamal; Martins, Daniel Lahan; Pereira, Ricardo Minniti Rodrigues

    2006-01-01

    Objective: To describe the different tomographic findings in hypodense hepatic lesions in children and its differential diagnosis. Materials and methods: computed tomographic studies were obtained from 50 patients (age range: 0-16 years) with low-density liver lesions previously diagnosed by ultrasound. Images were made before and after administration of intravenous contrast medium. Image findings were analyzed and afterwards correlated with anatomopathological diagnosis. Results: forty-seven of 50 cases were confirmed, 30 by anatomopathological diagnosis. Most of then were benign lesions, hemangioma in 20%. Such lesions presented a homogeneous contrast absorption, mainly at the delayed phase, differing from malignant lesions. Metastasis was the most frequently found malignant lesion (18%). Conclusion: computed tomographic study is of great value in complementing the diagnosis of hypodense hepatic lesions in children, and must follow ultrasound diagnosis as a routine procedure. (author)

  7. A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology

    International Nuclear Information System (INIS)

    Staton, R J; Pazik, F D; Nipper, J C; Williams, J L; Bolch, W E

    2003-01-01

    Establishment of organ doses from diagnostic and interventional examinations is a key component to quantifying the radiation risks from medical exposures and for formulating corresponding dose-reduction strategies. Radiation transport models of human anatomy provide a convenient method for simulating radiological examinations. At present, two classes of models exist: stylized mathematical models and tomographic voxel models. In the present study, organ dose comparisons are made for projection radiographs of both a stylized and a tomographic model of the newborn patient. Sixteen separate radiographs were simulated for each model at x-ray technique factors typical of newborn examinations: chest, abdomen, thorax and head views in the AP, PA, left LAT and right LAT projection orientation. For AP and PA radiographs of the torso (chest, abdomen and thorax views), the effective dose assessed for the tomographic model exceeds that for the stylized model with per cent differences ranging from 19% (AP abdominal view) to 43% AP chest view. In contrast, the effective dose for the stylized model exceeds that for the tomographic model for all eight lateral views including those of the head, with per cent differences ranging from 9% (LLAT chest view) to 51% (RLAT thorax view). While organ positioning differences do exist between the models, a major factor contributing to differences in effective dose is the models' exterior trunk shape. In the tomographic model, a more elliptical shape is seen thus providing for less tissue shielding for internal organs in the AP and PA directions, with corresponding increased tissue shielding in the lateral directions. This observation is opposite of that seen in comparisons of stylized and tomographic models of the adult

  8. X-ray Tomographic Microscopy at TOMCAT

    Energy Technology Data Exchange (ETDEWEB)

    Marone, F; Hintermueller, C; McDonald, S; Abela, R; Mikuljan, G; Isenegger, A; Stampanoni, M, E-mail: federica.marone@psi.c [Swiss Light Source, Paul Scherrer Institut, 5232 Villigen (Switzerland)

    2009-09-01

    Synchrotron-based X-ray Tomographic Microscopy is a powerful technique for fast non-destructive, high resolution quantitative volumetric investigations on diverse samples. At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline at the Swiss Light Source, synchrotron light is delivered by a 2.9 T superbend. The main optical component, a Double Crystal Multilayer Monochromator, covers an energy range between 8 and 45 keV. The standard TOMCAT detector offers field of views ranging from 0.75x0.75 mm{sup 2} up to 12.1x12.1 mm{sup 2} with a pixel size of 0.37 {mu}m and 5.92 {mu}m, respectively. In addition to routine measurements, which exploit the absorption contrast, the high coherence of the source also enables phase contrast tomography, implemented with two complementary techniques (Modified Transport of Intensity approach and Grating Interferometry). Typical acquisition times for a tomogram are in the order of few minutes, ensuring high throughput and allowing for semi-dynamical investigations. Raw data are automatically post-processed online and full reconstructed volumes are available shortly after a scan with minimal user intervention.

  9. The Effects of Receptive and Productive Learning of Word Pairs on Vocabulary Knowledge

    Science.gov (United States)

    Webb, Stuart

    2009-01-01

    English as a foreign language students in Japan learned target words in word pairs receptively and productively. Five aspects of vocabulary knowledge--orthography, association, syntax, grammatical functions, and meaning and form--were each measured by receptive and productive tests. The study uses an innovative methodology in that each target word…

  10. MCPT: A Monte Carlo code for simulation of photon transport in tomographic scanners

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Gardner, R.P.; Verghese, K.

    1990-01-01

    MCPT is a special-purpose Monte Carlo code designed to simulate photon transport in tomographic scanners. Variance reduction schemes and sampling games present in MCPT were selected to characterize features common to most tomographic scanners. Combined splitting and biasing (CSB) games are used to systematically sample important detection pathways. An efficient splitting game is used to tally particle energy deposition in detection zones. The pulse height distribution of each detector can be found by convolving the calculated energy deposition distribution with the detector's resolution function. A general geometric modelling package, HERMETOR, is used to describe the geometry of the tomographic scanners and provide MCPT information needed for particle tracking. MCPT's modelling capabilites are described and preliminary experimental validation is presented. (orig.)

  11. Active versus receptive group music therapy for major depressive disorder-A pilot study.

    Science.gov (United States)

    Atiwannapat, Penchaya; Thaipisuttikul, Papan; Poopityastaporn, Patchawan; Katekaew, Wanwisa

    2016-06-01

    To compare the effects of 1) active group music therapy and 2) receptive group music therapy to group counseling in treatment of major depressive disorder (MDD). On top of standard care, 14 MDD outpatients were randomly assigned to receive 1) active group music therapy (n=5), 2) receptive group music therapy (n=5), or 3) group counseling (n=4). There were 12 one-hour weekly group sessions in each arm. Participants were assessed at baseline, 1 month (after 4 sessions), 3 months (end of interventions), and 6 months. Primary outcomes were depressive scores measured by Montgomery-Åsberg Depression Rating Scale (MADRS) Thai version. Secondary outcomes were self-rated depression score and quality of life. At 1 month, 3 months, and 6 months, both therapy groups showed statistically non-significant reduction in MADRS Thai scores when compared with the control group (group counseling). The reduction was slightly greater in the active group than the receptive group. Although there were trend toward better outcomes on self-report depression and quality of life, the differences were not statistically significant. Group music therapy, either active or receptive, is an interesting adjunctive treatment option for outpatients with MDD. The receptive group may reach peak therapeutic effect faster, but the active group may have higher peak effect. Group music therapy deserves further comprehensive studies. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Tobacco Marketing Receptivity and Other Tobacco Product Use Among Young Adult Bar Patrons.

    Science.gov (United States)

    Thrul, Johannes; Lisha, Nadra E; Ling, Pamela M

    2016-12-01

    Use of other tobacco products (smokeless tobacco, hookah, cigarillo, and e-cigarettes) is increasing, particularly among young adults, and there are few regulations on marketing for these products. We examined the associations between tobacco marketing receptivity and other tobacco product (OTP) use among young adult bar patrons (aged 18-26 years). Time-location sampling was used to collect cross-sectional surveys from 7,540 young adult bar patrons from January 2012 through March of 2014. Multivariable logistic regression analyses in 2015 examined if tobacco marketing receptivity was associated (1) with current (past 30 day) OTP use controlling for demographic factors and (2) with dual/poly use among current cigarette smokers (n = 3,045), controlling for demographics and nicotine dependence. Among the entire sample of young adult bar patrons (Mean age  = 23.7, standard deviation = 1.8; 48.1% female), marketing receptivity was consistently associated with current use of all OTP including smokeless tobacco (adjusted odds ratio [AOR]= 2.56, 95% confidence interval [CI] 2.08-3.16, p marketing receptivity was significantly associated with use of smokeless tobacco (AOR = 1.63, 95% CI 1.22-2.18, p marketing receptivity. Efforts to limit tobacco marketing should address OTP in addition to cigarettes. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  13. Tomographic examination table

    International Nuclear Information System (INIS)

    Redington, R.W.; Henkes, J.L.

    1979-01-01

    Equipment is described for positioning and supporting patients during tomographic mammography using X-rays. The equipment consists of a table and fabric slings which permit the examination of a downward, pendant breast of a prone patient by allowing the breast to pass through a aperture in the table into a fluid filled container. The fluid has an X-ray absorption coefficient similar to that of soft human tissue allowing high density resolution radiography and permitting accurate detection of breast tumours. The shape of the equipment and the positioning of the patient allow the detector and X-ray source to rotate 360 0 about a vertical axis through the breast. This permits the use of relatively simple image reconstruction algorithms and a divergent X-ray geometry. (UK)

  14. K-pop Reception and Participatory Fan Culture in Austria

    Directory of Open Access Journals (Sweden)

    Sang-Yeon Sung

    2013-12-01

    Full Text Available K-pop’s popularity and its participatory fan culture have expanded beyond Asia and become significant in Europe in the past few years. After South Korean pop singer Psy’s “Gangnam Style” music video topped the Austrian chart in October 2012, the number and size of K-pop events in Austria sharply increased, with fans organizing various participatory events, including K-pop auditions, dance festivals, club meetings, quiz competitions, dance workshops, and smaller fan-culture gatherings. In the private sector, longtime fans have transitioned from participants to providers, and in the public sector, from observers to sponsors. Through in-depth interviews with event organizers, sponsors, and fans, this article offers an ethnographic study of the reception of K-pop in Europe that takes into consideration local interactions between fans and Korean sponsors, perspectives on the genre, patterns of social integration, and histories. As a case study, this research stresses the local situatedness of K-pop fan culture by arguing that local private and public sponsors and fans make the reception of K-pop different in each locality. By exploring local scenes of K-pop reception and fan culture, the article demonstrates the rapidly growing consumption of K-pop among Europeans and stresses multidirectional understandings of globalization.

  15. [New data on olfactory control of estral receptivity of female rats].

    Science.gov (United States)

    Satli, M A; Aron, C

    1976-03-01

    Olfactory bulb deprivation increased sexual receptivity in 4-day cyclic female rats on the late afternoon of prooestrus (6-7, p.m.). The proportion of receptive females was higher in bulbectomized (B) than in sham operated (SH) animals. On the contrary the same proportion of B and SH females mated in the evening of prooestrus (10. 30-11. 30 p.m.). An increased lordosis quotient was observed in the B females at either of these two stages of the cycle.

  16. The sentence verification task: a reliable fMRI protocol for mapping receptive language in individual subjects

    International Nuclear Information System (INIS)

    Sanjuan, Ana; Avila, Cesar; Forn, Cristina; Ventura-Campos, Noelia; Rodriguez-Pujadas, Aina; Garcia-Porcar, Maria; Belloch, Vicente; Villanueva, Vicente

    2010-01-01

    To test the capacity of a sentence verification (SV) task to reliably activate receptive language areas. Presurgical evaluation of language is useful in predicting postsurgical deficits in patients who are candidates for neurosurgery. Productive language tasks have been successfully elaborated, but more conflicting results have been found in receptive language mapping. Twenty-two right-handed healthy controls made true-false semantic judgements of brief sentences presented auditorily. Group maps showed reliable functional activations in the frontal and temporoparietal language areas. At the individual level, the SV task showed activation located in receptive language areas in 100% of the participants with strong left-sided distributions (mean lateralisation index of 69.27). The SV task can be considered a useful tool in evaluating receptive language function in individual subjects. This study is a first step towards designing the fMRI task which may serve to presurgically map receptive language functions. (orig.)

  17. The sentence verification task: a reliable fMRI protocol for mapping receptive language in individual subjects

    Energy Technology Data Exchange (ETDEWEB)

    Sanjuan, Ana; Avila, Cesar [Universitat Jaume I, Departamento de Psicologia Basica, Clinica y Psicobiologia, Castellon de la Plana (Spain); Hospital La Fe, Unidad de Epilepsia, Servicio de Neurologia, Valencia (Spain); Forn, Cristina; Ventura-Campos, Noelia; Rodriguez-Pujadas, Aina; Garcia-Porcar, Maria [Universitat Jaume I, Departamento de Psicologia Basica, Clinica y Psicobiologia, Castellon de la Plana (Spain); Belloch, Vicente [Hospital La Fe, Eresa, Servicio de Radiologia, Valencia (Spain); Villanueva, Vicente [Hospital La Fe, Unidad de Epilepsia, Servicio de Neurologia, Valencia (Spain)

    2010-10-15

    To test the capacity of a sentence verification (SV) task to reliably activate receptive language areas. Presurgical evaluation of language is useful in predicting postsurgical deficits in patients who are candidates for neurosurgery. Productive language tasks have been successfully elaborated, but more conflicting results have been found in receptive language mapping. Twenty-two right-handed healthy controls made true-false semantic judgements of brief sentences presented auditorily. Group maps showed reliable functional activations in the frontal and temporoparietal language areas. At the individual level, the SV task showed activation located in receptive language areas in 100% of the participants with strong left-sided distributions (mean lateralisation index of 69.27). The SV task can be considered a useful tool in evaluating receptive language function in individual subjects. This study is a first step towards designing the fMRI task which may serve to presurgically map receptive language functions. (orig.)

  18. Building Harmony through Religious Reception in Culture: Lesson Learned from Radin Jambat Folktale of Lampung

    Directory of Open Access Journals (Sweden)

    Agus Iswanto

    2018-12-01

    Full Text Available Understanding of the existence of various religious receptions in culture gives a great opportunity for the building and nurturance of harmony among religious followers and for the creating of solidarities in the society. This article uncovers receptions of religious aspects (ultimate truth aspect/god, cosmological aspect and religious ritual aspect in the cultural products of Radin Lambat, a folktale from Lampung. The article is based on the texts of Radin Lambat folktale, interviews, and other literary sources about Lampung cultures. Religious receptions as shown in Radin Lambat folktale indicate the preservation of past beliefs, coupled with the gentle addition and inclusion of Islamic teachings, to create harmonization between religion and tradition through folktale. This shows that Islam in the societies of Lampung is Islam that values cultures through the processes of gradual and varied receptions. This article is expected to add evidence to related sources about the concepts and practices of harmony among religious followers in Indonesia in local tradition, and the addition to the range of the rare religious-cultural reception studies of Lampung society

  19. Tomographic thallium-201 myocardial perfusion scintigrams after maximal coronary artery vasodilation with intravenous dipyridamole: comparison of qualitative and quantitative approaches

    International Nuclear Information System (INIS)

    Francisco, D.A.; Collins, S.M.; Go, R.T.; Ehrhardt, J.C.; Van Kirk, O.C.; Marcus, M.L.

    1982-01-01

    Eighty-six patients had thallium-201 ( 201 Tl) myocardial perfusion scintigrams after intense coronary artery dilation with i.v. dipyridamole. Tomographic and planar 201 Tl scintigrams were obtained in each patient. Tomographic scintigrams were interpreted using quantitative or visual criteria; planar scintigrams were assessed using visual criteria only. When visual criteria were used, interobserver variability was 40% for tomographic scintigrams and 44% for planar scintigrams. In the 24 patients with normal or nonsignificant CAD, quantitative analysis of the tomograms (range approach) indicated that one of 24 (4%) had a positive image (specificity 96%%); in contrast, when visual criteria were used to interpret the tomographic or planar 201 Tl scintigrams, eight of 24 (33%) had positive scintigrams (specificity 67%). In the 51 abnormal patients, the sensitivity of detecting CAD was 46 of 51 (90%) for tomographic scintigrams interpreted quantitatively, 39 of 51 (76%) for tomographic scintigrams interpreted visually and 41 of 51 (80%) for planar scintigrams assessed visually. The tomographic imaging procedure (quantitative interpretation) also demonstrated a high sensitivity (89%) and specificity (100%) in 28 patients (10 normal and 18 CAD), with a clinical diagnosis of unstable angina pectoris. Overall, the predictive accuracy of an abnormal scintigram with quantitative tomographic imaging (98%) was significantly better (p<0.05) than either qualitative planar or pinhole imaging

  20. Effects of Humor Production, Humor Receptivity, and Physical Attractiveness on Partner Desirability

    OpenAIRE

    Michelle Tornquist; Dan Chiappe

    2015-01-01

    This study examined women’s and men’s preferences for humor production and humor receptivity in long-term and short-term relationships, and how these factors interact with physical attractiveness to influence desirability. Undergraduates viewed photographs of the opposite sex individuals who were high or low in physical attractiveness, along with vignettes varying in humor production and receptivity. Participants rated physical attractiveness and desirability for long-term and short-term rela...

  1. A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals

    International Nuclear Information System (INIS)

    Ziegler, S.I.; Pichler, B.J.; Rafecas, M.; Schwaiger, M.

    2001-01-01

    To fully utilize positron emission tomography (PET) as a non-invasive tool for tissue characterization, dedicated instrumentation is being developed which is specially suited for imaging mice and rats. Semiconductor detectors, such as avalanche photodiodes (APDs), may offer an alternative to photomultiplier tubes for the readout of scintillation crystals. Since the scintillation characteristics of lutetium oxyorthosilicate (LSO) are well matched to APDs, the combination of LSO and APDs seems favourable, and the goal of this study was to build a positron tomograph with LSO-APD modules to prove the feasibility of such an approach. A prototype PET scanner based on APD readout of small, individual LSO crystals was developed for tracer studies in mice and rats. The tomograph consists of two sectors (86 mm distance), each comprising three LSO-APD modules, which can be rotated for the acquisition of complete projections. In each module, small LSO crystals (3.7 x 3.7 x 12 mm 3 ) are individually coupled to one channel within matrices containing 2 x 8 square APDs (2.6 x 2.6 mm 2 sensitive area per channel). The list-mode data are reconstructed with a penalized weighted least squares algorithm which includes the spatially dependent line spread function of the tomograph. Basic performance parameters were measured with phantoms and first experiments with rats and mice were conducted to introduce this methodology for biomedical imaging. The reconstructed field of view covers 68 mm, which is 80% of the total detector diameter. Image resolution was shown to be 2.4 mm within the whole reconstructed field of view. Using a lower energy threshold of 450 keV, the system sensitivity was 350 Hz/MBq for a line source in air in the centre of the field of view. In a water-filled cylinder of 4.6 cm diameter, the scatter fraction at the centre of the field of view was 16% (450 keV threshold). The count rate was linear up to 700 coincidence counts per second. In vivo studies of anaesthetized

  2. Rapid tomographic reconstruction based on machine learning for time-resolved combustion diagnostics

    Science.gov (United States)

    Yu, Tao; Cai, Weiwei; Liu, Yingzheng

    2018-04-01

    Optical tomography has attracted surged research efforts recently due to the progress in both the imaging concepts and the sensor and laser technologies. The high spatial and temporal resolutions achievable by these methods provide unprecedented opportunity for diagnosis of complicated turbulent combustion. However, due to the high data throughput and the inefficiency of the prevailing iterative methods, the tomographic reconstructions which are typically conducted off-line are computationally formidable. In this work, we propose an efficient inversion method based on a machine learning algorithm, which can extract useful information from the previous reconstructions and build efficient neural networks to serve as a surrogate model to rapidly predict the reconstructions. Extreme learning machine is cited here as an example for demonstrative purpose simply due to its ease of implementation, fast learning speed, and good generalization performance. Extensive numerical studies were performed, and the results show that the new method can dramatically reduce the computational time compared with the classical iterative methods. This technique is expected to be an alternative to existing methods when sufficient training data are available. Although this work is discussed under the context of tomographic absorption spectroscopy, we expect it to be useful also to other high speed tomographic modalities such as volumetric laser-induced fluorescence and tomographic laser-induced incandescence which have been demonstrated for combustion diagnostics.

  3. Assessment of hemispheric dominance for receptive language in pediatric patients under sedation using magnetoencephalography.

    Science.gov (United States)

    Rezaie, Roozbeh; Narayana, Shalini; Schiller, Katherine; Birg, Liliya; Wheless, James W; Boop, Frederick A; Papanicolaou, Andrew C

    2014-01-01

    Non-invasive assessment of hemispheric dominance for receptive language using magnetoencephalography (MEG) is now a well-established procedure used across several epilepsy centers in the context of pre-surgical evaluation of children and adults while awake, alert and attentive. However, the utility of MEG for the same purpose, in cases of sedated patients, is contested. Establishment of the efficiency of MEG is especially important in the case of children who, for a number of reasons, must be assessed under sedation. Here we explored the efficacy of MEG language mapping under sedation through retrospective review of 95 consecutive pediatric patients, who underwent our receptive language test as part of routine clinical evaluation. Localization of receptive language cortex and subsequent determination of laterality was successfully completed in 78% (n = 36) and 55% (n = 27) of non-sedated and sedated patients, respectively. Moreover, the proportion of patients deemed left hemisphere dominant for receptive language did not differ between non-sedated and sedated patients, exceeding 90% in both groups. Considering the challenges associated with assessing brain function in pediatric patients, the success of passive MEG in the context of the cases reviewed in this study support the utility of this method in pre-surgical receptive language mapping.

  4. Assessment of hemispheric dominance for receptive language in pediatric patients under sedation using magnetoencephalography

    Directory of Open Access Journals (Sweden)

    Roozbeh eRezaie

    2014-08-01

    Full Text Available Non-invasive assessment of hemispheric dominance for receptive language using Magnetoencephalography (MEG is now a well-established procedure used across several epilepsy centers in the context of pre-surgical evaluation of children and adults while awake, alert and attentive. However, the utility of MEG for the same purpose, in cases of sedated patients, is contested. Establishment of the efficiency of MEG is especially important in the case of children who, for a number of reasons, must be assessed under sedation. Here we explored the efficacy of MEG language mapping under sedation through retrospective review of 95 consecutive pediatric patients, who underwent our receptive language test as part of routine clinical evaluation. Localization of receptive language cortex and subsequent determination of laterality was successfully completed in 78% (n=36 and 55% (n=27 of non-sedated and sedated patients, respectively. Moreover, the proportion of patients deemed left hemisphere dominant for receptive language did not differ between non-sedated and sedated patients, exceeding 90% in both groups. Considering the challenges associated with assessing brain function in pediatric patients, the success of passive MEG in the context of the cases reviewed in this study support the utility of this method in pre-surgical receptive language mapping.

  5. Contour detection based on nonclassical receptive field inhibition

    NARCIS (Netherlands)

    Grigorescu, Cosmin; Petkov, Nicolai; Westenberg, Michel A.

    We propose a biologically motivated computational step, called nonclassical receptive field (non-CRF) inhibition, more generally surround inhibition or suppression, to improve contour detection in machine vision. Non-CRF inhibition is exhibited by 80% of the orientation-selective neurons in the

  6. A communicational framework for evaluating interaction with IT by analyzing user-reception of electronic texts

    DEFF Research Database (Denmark)

    Wentzer, Helle

    2006-01-01

    Interpreting IT as a medium for continuous communication across time and place of the communicators offers a way of analyzing the effect of IT in concrete practices. The users’ readings determine the actual communication with IT. A poetics of how meaning is translated from one person to another...... through semiotic texts is presented, termed the poetics of the e-text. The poetics of the e-text offers a meta-communicational framework for identifying user constraints in the possibilities of interacting with the system. Identifying communicational problems with ICT-mediated interactions again offer...... grounds for redesigning and re-author the e-text. The poetics of the e-text are subsequently applied as a method of analyzing user-reception and evaluating the interaction with ICT. Examples are given from user-receptions of collaborating with ICT in home care, Denmark....

  7. Improved CORF model of simple cell combined with non-classical receptive field and its application on edge detection

    Science.gov (United States)

    Sun, Xiao; Chai, Guobei; Liu, Wei; Bao, Wenzhuo; Zhao, Xiaoning; Ming, Delie

    2018-02-01

    Simple cells in primary visual cortex are believed to extract local edge information from a visual scene. In this paper, inspired by different receptive field properties and visual information flow paths of neurons, an improved Combination of Receptive Fields (CORF) model combined with non-classical receptive fields was proposed to simulate the responses of simple cell's receptive fields. Compared to the classical model, the proposed model is able to better imitate simple cell's physiologic structure with consideration of facilitation and suppression of non-classical receptive fields. And on this base, an edge detection algorithm as an application of the improved CORF model was proposed. Experimental results validate the robustness of the proposed algorithm to noise and background interference.

  8. Consuming Carmen Miranda: Dislocations and Dissonances in the Reception of an Icon

    Directory of Open Access Journals (Sweden)

    Fernando de Figueiredo Balieiro

    2017-02-01

    Full Text Available From the perspective of cultural studies, in its dialogs with feminist and queer studies, this article analyzes the identification of various publics with Carmen Miranda based on the consumption of her filmic, musical and artistic products, accessing her professional trajectory in its imbrication with its various forms of reception. The focus will be on the negotiations of the artist with her publics, touching on how her career involved reconfigurations concerning aspects of gender, race and sexuality. It is based on a perspective that considers the dynamism of mass culture, considering possibilities for various forms of appropriation of cultural products, as well as shifts and dissonances in receptions. To analyze these aspects, the paper focuses on feminine receptions in Brazil and the United States, and those of a male homosexual public contemporary to her career.

  9. Constraining fault interpretation through tomographic velocity gradients: application to northern Cascadia

    Directory of Open Access Journals (Sweden)

    K. Ramachandran

    2012-02-01

    Full Text Available Spatial gradients of tomographic velocities are seldom used in interpretation of subsurface fault structures. This study shows that spatial velocity gradients can be used effectively in identifying subsurface discontinuities in the horizontal and vertical directions. Three-dimensional velocity models constructed through tomographic inversion of active source and/or earthquake traveltime data are generally built from an initial 1-D velocity model that varies only with depth. Regularized tomographic inversion algorithms impose constraints on the roughness of the model that help to stabilize the inversion process. Final velocity models obtained from regularized tomographic inversions have smooth three-dimensional structures that are required by the data. Final velocity models are usually analyzed and interpreted either as a perturbation velocity model or as an absolute velocity model. Compared to perturbation velocity model, absolute velocity models have an advantage of providing constraints on lithology. Both velocity models lack the ability to provide sharp constraints on subsurface faults. An interpretational approach utilizing spatial velocity gradients applied to northern Cascadia shows that subsurface faults that are not clearly interpretable from velocity model plots can be identified by sharp contrasts in velocity gradient plots. This interpretation resulted in inferring the locations of the Tacoma, Seattle, Southern Whidbey Island, and Darrington Devil's Mountain faults much more clearly. The Coast Range Boundary fault, previously hypothesized on the basis of sedimentological and tectonic observations, is inferred clearly from the gradient plots. Many of the fault locations imaged from gradient data correlate with earthquake hypocenters, indicating their seismogenic nature.

  10. The electronics for the Donner 600-Crystal Positron Tomograph

    International Nuclear Information System (INIS)

    Cahoon, J.L.; Huesman, R.H.; Derenzo, S.E.; Geyer, A.B.; Uber, D.C.; Turko, B.T.; Budinger, T.F.

    1986-01-01

    The data acquisition system, designed for the Donner 600-Crystal Positron Tomograph, is described. Coincidence timing resolution of less than five nanoseconds full width at half maximum and data rates in excess of one million events per second are achieved by using high-speed emitter coupled logic circuits, first-in first-out memory to derandomize data flow, and parallel architecture to increase throughput. These data rates allow the acquisition of adequate transmission data in a reasonable amount of time. Good timing resolution minimizes accidental coincidences and permits data rates greater than 100,000 image-forming events per second for high-speed dynamic emission tomography. Additional scatter and accidental rejection are accomplished for transmission data by using an orbiting source and a look-up table for valid events. Calibration of this complex electronic system is performed automatically under computer control

  11. Directional fine structure in absorption of white x rays: A tomographic interpretation

    International Nuclear Information System (INIS)

    Korecki, P.; Szymonski, M.; Tolkiehn, M.; Novikov, D. V.; Materlik, G.

    2006-01-01

    We discuss directional fine structure in absorption of white x rays for tomographic imaging of crystal structure at the atomic level. The interference between a direct x-ray beam and the secondary waves coherently scattered inside a specimen modifies the total wave field at the position of the absorbing atoms. For a white x-ray beam, the wave field variations cancel out by energy integration for all directions, except for the near forward scattering components, coinciding with the incident beam. Therefore, two-dimensional patterns of the angular-dependent fine structure in absorption of white x rays can be interpreted as real-space projections of atomic structure. In this work, we present a theory describing the directional fine structure in white x-ray absorption and a tomographic approach for crystal structure retrieval developed on its basis. The tomographic algorithm is applied to the experimental x-ray absorption data recorded for GaP crystals

  12. Automated angular and translational tomographic alignment and application to phase-contrast imaging

    DEFF Research Database (Denmark)

    Cunha Ramos, Tiago Joao; Jørgensen, Jakob Sauer; Andreasen, Jens Wenzel

    2017-01-01

    X-ray computerized tomography (CT) is a 3D imaging technique that makes use of x-ray illumination and image reconstruction techniques to reproduce the internal cross-sections of a sample. Tomographic projection data usually require an initial relative alignment or knowledge of the exact object po...... improvement in the reconstruction resolution. A MATLAB implementation is made publicly available and will allow robust analysis of large volumes of phase-contrast tomography data.......X-ray computerized tomography (CT) is a 3D imaging technique that makes use of x-ray illumination and image reconstruction techniques to reproduce the internal cross-sections of a sample. Tomographic projection data usually require an initial relative alignment or knowledge of the exact object...... reconstruction artifacts and limit the attained resolution in the final tomographic reconstruction. Alignment algorithms that require manual interaction impede data analysis with ever-increasing data acquisition rates, supplied by more brilliant sources. We present in this paper an iterative reconstruction...

  13. Bone densitometry with the computer tomograph

    International Nuclear Information System (INIS)

    Weiss, T.

    1978-01-01

    This work tests the usefulness of the EMI head scanner MARK I for a quantitative detection of ossary mineral content. Twenty-three concentration levels of a aqueous K 2 HPO 4 -solution were positioned by means of a special clamping device at the EMI-scanner and examined at tubevoltages of 100, 120 and 140 kV. This produces an almost linear dependence between CT-unit and sample concentration, whereby it shows that the measured special element densities of samples with the same densities vary in dependence with the voltage. The examination of an anotomical fore-arm preperate served as a statement for the reproductability of computer tomographic densitometry at non-moving biological objects. The test of reproductability of bone densitometry measurements under clinical conditions was made on the occation of the six time examinations of the right hand fore-arm bone of a young dummy. Furthermore densitometric examination were made at the fore-arm shelton of 40 long-time dialysis patients in the age levels between 17 and 67 years. The reproductability of the technique presented here is at least not better with the EMI-head-scanner MARK I used here. A change is possible by using the new whole body tomographs. (orig./MG) [de

  14. Signal processing and general purpose data acquisition system for on-line tomographic measurements

    Science.gov (United States)

    Murari, A.; Martin, P.; Hemming, O.; Manduchi, G.; Marrelli, L.; Taliercio, C.; Hoffmann, A.

    1997-01-01

    New analog signal conditioning electronics and data acquisition systems have been developed for the soft x-ray and bolometric tomography diagnostic in the reverse field pinch experiment (RFX). For the soft x-ray detectors the analog signal processing includes a fully differential current to voltage conversion, with up to a 200 kHz bandwidth. For the bolometers, a 50 kHz carrier frequency amplifier allows a maximum bandwidth of 10 kHz. In both cases the analog signals are digitized with a 1 MHz sampling rate close to the diagnostic and are transmitted via a transparent asynchronous xmitter/receiver interface (TAXI) link to purpose built Versa Module Europa (VME) modules which perform data acquisition. A software library has been developed for data preprocessing and tomographic reconstruction. It has been written in C language and is self-contained, i.e., no additional mathematical library is required. The package is therefore platform-free: in particular it can perform online analysis in a real-time application, such as continuous display and feedback, and is portable for long duration fusion or other physical experiments. Due to the modular organization of the library, new preprocessing and analysis modules can be easily integrated in the environment. This software is implemented in RFX over three different platforms: open VMS, digital Unix, and VME 68040 CPU.

  15. Transfer and Reception of New Institutional Economics: An Example of Two Universities in Serbia

    Directory of Open Access Journals (Sweden)

    Aleksandra Jovanović

    2016-02-01

    Full Text Available The research “Transfer and Reception of New Institutional Economics: An Example of Two Universities in Serbia” was conducted in 2005/2006. In order to achieve the goals of the Serbian team of the DIOSCURI project, the main aim of the case study is analysis of the influence of Western institutions in the light of transfer and reception of new institutional economics in two academic institutions in Serbia: The Faculty of Law (The Department of Law and Economics of the University of Belgrade, and The Faculty of Management of BK University. The title of the case study illustrates the focus of the entire research: analysis of Western influence, namely transfer and reception of new institutional economics, on the two institutions and possible obstacles caused by old-fashioned stakeholders and informal institutions. Bearing in mind that the Department of Law and Economics is the leader in the reception of the new institutional economics (NIE in Serbia, the case study will be mostly about it. The Faculty of Management was chosen because of its “greenfield” character and the fact that from its very beginning it followed the experiences of North American universities. The research investigates whether and how the transfer and reception of the Western ideas and economic theory, particularly the NIE, is affected by the difference between an institution with a two-hundred-year tradition and a newly established one. The question is how a traditionalist institution like the Faculty of Law communicated Western economic thought and whether endurance in teaching the exclusively Marxian paradigm up until the 1990s, was an obstacle to the reception of Western economic thought, particularly NIE.

  16. Social media-based civic engagement solutions for dengue prevention in Sri Lanka: results of receptivity assessment.

    Science.gov (United States)

    Lwin, May O; Vijaykumar, Santosh; Foo, Schubert; Fernando, Owen Noel Newton; Lim, Gentatsu; Panchapakesan, Chitra; Wimalaratne, Prasad

    2016-02-01

    This article focuses on a novel social media-based system that addresses dengue prevention through an integration of three components: predictive surveillance, civic engagement and health education. The aim was to conduct a potential receptivity assessment of this system among smartphone users in the city of Colombo, the epicenter of the dengue epidemic in the island country of Sri Lanka. Grounded in Protection Motivation Theory (PMT) and using a convenience sampling approach, the cross-sectional survey assessed perceived severity (PSe), perceived susceptibility (PSu), perceived response efficacy (PRE), perceived self-efficacy (PSE) and intention-to-use (IU) among 513 individuals. The overall receptivity to the system was high with a score of >4.00 on a five-point scale. Participants belonging to younger, better educated and higher income groups reported significantly better perceptions of the efficaciousness of the system, were confident in their ability to use the system, and planned to use it in the future. PMT variables contributed significantly to regression models predicting IU. We concluded that a social media-based system for dengue prevention will be positively received among Colombo residents and a targeted, strategic health communication effort to raise dengue-related threat perceptions will be needed to encourage greater adoption and use of the system. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  17. Adolescent weight status and receptivity to food TV advertisements.

    Science.gov (United States)

    Adachi-Mejia, Anna M; Sutherland, Lisa A; Longacre, Meghan R; Beach, Michael L; Titus-Ernstoff, Linda; Gibson, Jennifer J; Dalton, Madeline A

    2011-01-01

    This study examined the relationship between adolescent weight status and food advertisement receptivity. Survey-based evaluation with data collected at baseline (initial and at 2 months), and at follow-up (11 months). New Hampshire and Vermont. Students (n = 2,281) aged 10-13 in 2002-2005. Overweight. Generalized estimating equations to model the relationship between identifying a food advertisement as their favorite and being overweight. Overall, 35.9% of the adolescents were overweight. Less than one fifth named a food advertisement as their favorite (16.1%). Most of the food advertisements were for less-healthful food (89.6%). After controlling for school, age, sex, sociodemographics, physical activity, number of TV sessions watched, and having a TV in the bedroom, overweight adolescents were significantly less likely to be receptive to food advertisements (relative risk = 0.83, 95% confidence interval 0.70, 0.98) compared to non-overweight adolescents. This study provides preliminary evidence that normal-weight adolescents are receptive to unhealthful food advertisements. Longitudinal studies are needed to evaluate whether consistent exposure to advertisements for unhealthful food, particularly if they are promoted with healthful behaviors such as being physically active, influence adolescents' food choices, and ultimately their body mass index, over the long term. Copyright © 2011 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  18. Depression. Does it affect the comprehension of receptive skills?

    Science.gov (United States)

    Rashtchi, Mojgan; Zokaee, Zahra; Ghaffarinejad, Ali R; Sadeghi, Mohammad M

    2012-07-01

    To compare the comprehension of depressed and non-depressed male and female Iranian learners of English as a Foreign Language (EFL) in receptive skills, and to investigate whether inefficiency in learning English could be due to depression. We selected 126 boys and 96 girls aged between 15 and 18 by simple random sampling from 2 high schools in Kerman, Iran to examine whether there was any significant relationship between depression and comprehension of receptive skills in males and females. We undertook this descriptive, correlational study between January and May 2011 in Kerman, Iran. After administration of the Beck Depression Inventory (BDI), we found that 93 students were non-depressed, 65 had minimal depression, 48 mild depression, and 16 suffered from severe depression. The correlation between participants` scores on listening and reading test with depression level indicated a significant relationship between depression and comprehension of both listening, and reading. Males had higher scores in both reading and listening. In listening, there was no significant difference among the levels of depression and males and females. Regarding the reading skill, there was no significant difference among levels of depression; however, the reading comprehension of males and females differed significantly. Learners who show a deficiency in receptive skills should be examined for the possibility of suffering from some degree of depression.

  19. Performance of analytical methods for tomographic gamma scanning

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Mercer, D.J.

    1997-01-01

    The use of gamma-ray computerized tomography for nondestructive assay of radioactive materials has led to the development of specialized analytical methods. Over the past few years, Los Alamos has developed and implemented a computer code, called ARC-TGS, for the analysis of data obtained by tomographic gamma scanning (TGS). ARC-TGS reduces TGS transmission and emission tomographic data, providing the user with images of the sample contents, the activity or mass of selected radionuclides, and an estimate of the uncertainty in the measured quantities. The results provided by ARC-TGS can be corrected for self-attenuation when the isotope of interest emits more than one gamma-ray. In addition, ARC-TGS provides information needed to estimate TGS quantification limits and to estimate the scan time needed to screen for small amounts of radioactivity. In this report, an overview of the analytical methods used by ARC-TGS is presented along with an assessment of the performance of these methods for TGS

  20. The computed tomographic appearances of cherubism

    International Nuclear Information System (INIS)

    Bianchi, S.D.; Boccardi, A.; Mela, F.; Romagnoli, R.

    1987-01-01

    The computed tomographic (CT) aspects of six cases of cherubism are described. Through its optimal representation of the lesions, CT enabled certain characteristics of this disease to be substantiated, namely, limitation of the process to the bones of the jaw and primarily superficial development of the mandibular lesions, coupled with an unusual mandibular condylar impairment. Moreover, the composition of this series permitted investigation of the condition in its several stages of progression. (orig.)

  1. Radiation Emergency Preparedness Tools: Virtual Community Reception Center

    Centers for Disease Control (CDC) Podcasts

    This podcast is an overview of resources from the Clinician Outreach and Communication Activity (COCA) Call: Practical Tools for Radiation Emergency Preparedness. A specialist working with CDC's Radiation Studies Branch describes a web-based training tool known as a Virtual Community Reception Center (vCRC).

  2. ”Savage Spain”? On the reception of Spanish art in Britain and Ireland

    Directory of Open Access Journals (Sweden)

    Edward Payne

    2011-12-01

    Full Text Available Review of: Nigel Glendinning and Hilary Macartney, eds, Spanish Art in Britain and Ireland, 1750–1920: Studies in Reception in Memory of Enriqueta Harris Frankfort, Woodbridge: Tamesis, 2010. This review evaluates the first scholarly study exclusively dedicated to the reception history of Spanish art in Britain and Ireland, 1750–1920. Progressing systematically through the different chapters, it highlights the various responses and perspectives that are addressed in the book. Issues of taste and collecting are examined, followed by historiographical concerns such as the methods and techniques of writing, illustrating and reproducing Spanish art in the nineteenth century. Shifting attitudes towards Spain and Spanish art are also explored, as are the roles of prominent figures in disseminating knowledge and appreciation of Spanish art, notably Sir William Stirling Maxwell and Richard Ford. Finally, the review outlines the critical fortunes of Spain’s foremost artists: Murillo, Velázquez, Ribera, Zurbarán and Goya. It ends by suggesting how this study could be expanded methodologically, considering the reception history of Spanish art in the light of important literature on reception theory and aesthetics.

  3. Case study of French and Spanish fan reception of Game of Thrones

    Directory of Open Access Journals (Sweden)

    Mélanie Bourdaa

    2015-06-01

    Full Text Available The reception of the American TV show Game of Thrones (2011– by French and Spanish fans and nonfans is addressed via a qualitative methodology, the goal of which is to understand how European viewers perceive themselves as fans and what it means for them to be fans. Analysis of characteristics of a specifically European reception helps us learn what fan studies tell us about fans and what fans really think about fandoms.

  4. First-year university students' receptive and productive use of ...

    African Journals Online (AJOL)

    Kate H

    Keywords: academic vocabulary, receptive knowledge, productive knowledge, collocations, vocabulary ...... The challenge of validation: Assessing the performance of a test of ..... This is a new drug used to tr…………… depression. 56.

  5. Motion tracking-enhanced MART for tomographic PIV

    International Nuclear Information System (INIS)

    Novara, Matteo; Scarano, Fulvio; Batenburg, Kees Joost

    2010-01-01

    A novel technique to increase the accuracy of multiplicative algebraic reconstruction technique (MART) reconstruction from tomographic particle image velocimetry (PIV) recordings at higher seeding density than currently possible is presented. The motion tracking enhancement (MTE) method is based on the combined utilization of images from two or more exposures to enhance the reconstruction of individual intensity fields. The working principle is first introduced qualitatively, and the mathematical background is given that explains how the MART reconstruction can be improved on the basis of an improved first guess object obtained from the combination of non-simultaneous views reduced to the same time instant deforming the 3D objects by an estimate of the particle motion field. The performances of MTE are quantitatively evaluated by numerical simulation of the imaging, reconstruction and image correlation processes. The cases of two or more exposures obtained from time-resolved experiments are considered. The iterative application of MTE appears to significantly improve the reconstruction quality, first by decreasing the intensity of the ghost images and second, by increasing the intensity and the reconstruction precision for the actual particles. Based on computer simulations, the maximum imaged seeding density that can be dealt with is tripled with respect to the MART analysis applied to a single exposure. The analysis also illustrates that the maximum effect of the MTE method is comparable to that of doubling the number of cameras in the tomographic system. Experiments performed on a transitional jet at Re = 5000 apply the MTE method to double-frame recordings. The velocity measurement precision is increased for a system with fewer views (two or three cameras compared with four cameras). The ghost particles' intensity is also visibly reduced although to a lesser extent with respect to the computer simulations. The velocity and vorticity field obtained from a three

  6. The Reception of German Progressive Education in Russia: On Regularities of International Educational Transfer

    Science.gov (United States)

    Mchitarjan, Irina

    2015-01-01

    This article reports a historical case study of extensive educational transfer: the reception, adaptation, and use of German progressive education and German school reform ideas and practices in Russia at the beginning of the twentieth century. The reception of German educational ideas greatly enriched the theory and practice of the Russian school…

  7. DG TOMO: A new method for tomographic reconstruction

    International Nuclear Information System (INIS)

    Freitas, D. de; Feschet, F.; Cachin, F.; Geissler, B.; Bapt, A.; Karidioula, I.; Martin, C.; Kelly, A.; Mestas, D.; Gerard, Y.; Reveilles, J.P.; Maublant, J.

    2006-01-01

    Aim: FBP and OSEM are the most popular tomographic reconstruction methods in scintigraphy. FBP is a simple method but artifacts of reconstruction are generated which corrections induce degradation of the spatial resolution. OSEM takes account of statistical fluctuations but noise strongly increases after a certain number of iterations. We compare a new method of tomographic reconstruction based on discrete geometry (DG TOMO) to FBP and OSEM. Materials and methods: Acquisitions were performed on a three-head gamma-camera (Philips) with a NEMA Phantom containing six spheres of sizes from 10 to 37 mm inner diameter, filled with around 325 MBq/l of technetium-99 m. The spheres were positioned in water containing 3 MBq/l of technetium-99 m. Acquisitions were realized during a 180 o -rotation around the phantom by 25-s steps. DG TOMO has been developed in our laboratory in order to minimize the number of projections at acquisition. Two tomographic reconstructions utilizing 32 and 16 projections with FBP, OSEM and DG TOMO were performed and transverse slices were compared. Results: FBP with 32 projections detects only the activity in the three largest spheres (diameter ≥22 mm). With 16 projections, the star effect is predominant and the contrast of the third sphere is very low. OSEM with 32 projections provides a better image but the three smallest spheres (diameter ≤17 mm) are difficult to distinguish. With 16 projections, the three smaller spheres are not detectable. The results of DG TOMO are similar to OSEM. Conclusion: Since the parameters of DG TOMO can be further optimized, this method appears as a promising alternative for tomoscintigraphy reconstruction

  8. Learning color receptive fields and color differential structure

    NARCIS (Netherlands)

    ter Haar Romenij, B.M.

    2016-01-01

    In this paper we study the role of brain plasticity, and investigate the emergence and self-emergence of receptive fields from scalar and color natural images by principal component analysis of image patches. We describe the classical experiment on localized PCA on center-surround weighted patches

  9. Risk factors for children's receptive vocabulary development from four to eight years in the longitudinal study of Australian children.

    Directory of Open Access Journals (Sweden)

    Catherine L Taylor

    Full Text Available Receptive vocabulary develops rapidly in early childhood and builds the foundation for language acquisition and literacy. Variation in receptive vocabulary ability is associated with variation in children's school achievement, and low receptive vocabulary ability is a risk factor for under-achievement at school. In this study, bivariate and multivariate growth curve modelling was used to estimate trajectories of receptive vocabulary development in relation to a wide range of candidate child, maternal and family level influences on receptive vocabulary development from 4-8 years. The study sample comprised 4332 children from the first nationally representative Longitudinal Study of Australian Children (LSAC. Predictors were modeled as risk variables with the lowest level of risk as the reference category. In the multivariate model, risks for receptive vocabulary delay at 4 years, in order of magnitude, were: Maternal Non- English Speaking Background (NESB, low school readiness, child not read to at home, four or more siblings, low family income, low birthweight, low maternal education, maternal mental health distress, low maternal parenting consistency, and high child temperament reactivity. None of these risks were associated with a lower rate of growth from 4-8 years. Instead, maternal NESB, low school readiness and maternal mental health distress were associated with a higher rate of growth, although not sufficient to close the receptive vocabulary gap for children with and without these risks at 8 years. Socio-economic area disadvantage, was not a risk for low receptive vocabulary ability at 4 years but was the only risk associated with a lower rate of growth in receptive vocabulary ability. At 8 years, the gap between children with and without socio-economic area disadvantage was equivalent to eight months of receptive vocabulary growth. These results are consistent with other studies that have shown that social gradients in children

  10. Risk factors for children's receptive vocabulary development from four to eight years in the longitudinal study of Australian children.

    Science.gov (United States)

    Taylor, Catherine L; Christensen, Daniel; Lawrence, David; Mitrou, Francis; Zubrick, Stephen R

    2013-01-01

    Receptive vocabulary develops rapidly in early childhood and builds the foundation for language acquisition and literacy. Variation in receptive vocabulary ability is associated with variation in children's school achievement, and low receptive vocabulary ability is a risk factor for under-achievement at school. In this study, bivariate and multivariate growth curve modelling was used to estimate trajectories of receptive vocabulary development in relation to a wide range of candidate child, maternal and family level influences on receptive vocabulary development from 4-8 years. The study sample comprised 4332 children from the first nationally representative Longitudinal Study of Australian Children (LSAC). Predictors were modeled as risk variables with the lowest level of risk as the reference category. In the multivariate model, risks for receptive vocabulary delay at 4 years, in order of magnitude, were: Maternal Non- English Speaking Background (NESB), low school readiness, child not read to at home, four or more siblings, low family income, low birthweight, low maternal education, maternal mental health distress, low maternal parenting consistency, and high child temperament reactivity. None of these risks were associated with a lower rate of growth from 4-8 years. Instead, maternal NESB, low school readiness and maternal mental health distress were associated with a higher rate of growth, although not sufficient to close the receptive vocabulary gap for children with and without these risks at 8 years. Socio-economic area disadvantage, was not a risk for low receptive vocabulary ability at 4 years but was the only risk associated with a lower rate of growth in receptive vocabulary ability. At 8 years, the gap between children with and without socio-economic area disadvantage was equivalent to eight months of receptive vocabulary growth. These results are consistent with other studies that have shown that social gradients in children's developmental outcomes

  11. Evaluation of receptivity of the medical students in a lecture of a large group

    Directory of Open Access Journals (Sweden)

    Vidyarthi SurendraK, Nayak RoopaP, GuptaSandeep K

    2014-04-01

    Full Text Available Background: Lecturing is widely used teaching method in higher education. Instructors of large classes may have only option to deliver lecture to convey informations to large group students.Aims and Objectives: The present study was to evaluate the effectiveness/receptivity of interactive lecturing in a large group of MBBS second year students. Material and Methods: The present study was conducted in the well-equipped lecture theater of Dhanalakshmi Srinivasan Medical College and Hospital (DSMCH, Tamil Nadu. A fully prepared interactive lecture on the specific topic was delivered by using power point presentation for second year MBBS students. Before start to deliver the lecture, instructor distributed multiple choice 10 questionnaires to attempt within 10 minutes. After 30 minutes of delivering lecture, again instructor distributed same 10 sets of multiple choice questionnaires to attempt in 10 minutes. The topic was never disclosed to the students before to deliver the lecture. Statistics: We analyzed the pre-lecture & post-lecture questions of each student by applying the paired t-test formula by using www.openepi.com version 3.01 online/offline software and by using Microsoft Excel Sheet Windows 2010. Results: The 31 male, 80 female including 111 students of average age 18.58 years baseline (pre-lecture receptivity mean % was 30.99 ± 14.64 and post-lecture receptivity mean % was increased upto 53.51± 19.52. The only 12 students out of 111 post-lecture receptivity values was less (mean % 25.8± 10.84 than the baseline (mean % 45± 9.05 receptive value and this reduction of receptivity was more towards negative side. Conclusion: In interactive lecture session with power point presentation students/learners can learn, even in large-class environments, but it should be active-learner centered.

  12. Relation of the measuring values in cephalometric radiographs and TMJ tomographs

    Energy Technology Data Exchange (ETDEWEB)

    Han, Jin Woo [Kangnung National Univ. College of Dentistry, Kangnung (Korea, Republic of)

    2007-03-15

    To examine whether the maxillofacial skeletal morphology correlates with the condylar position and the anatomic characteristics of articular eminence using measurements of lateral cephalometric radiographs and individualized sagittal temporomandibular joint (TMJ) tomographs. I compared measurements of 202 TMJs of 101 orthodontic patients of Kangnung National University Dental Hospital. I used Pearson's correlation for comparison of the measuring values in lateral cephalometric radiographs and individualized sagittal TMJ tomographs. Large occlusal plane angle tendency showed decreased width of posterior eminence slope, decreased depth of articular fossa and decreased posterior slope angle of eminence. Large mandibular plane angle tendency showed decreased superior joint space, decreased superior joint space, decreased depth of articular fossa and decreased posterior slope angle of eminence. Large genial angle tendency showed decreased depth of articular fossa, decreased posterior slope angle of eminence and anterior position of comdylar head. Large anterior facial height and large posterior facial height tendency showed increased width of posterior position of condylar head. Maxillofacial skeletal morphology has correlation with the anatomic characteristics of TMJ. Individualized sagittal TMJ tomographs can provide useful information for anatomical analysis of TMJ.

  13. Tomographic Particle Image Velocimetry using Smartphones and Colored Shadows

    KAUST Repository

    Aguirre-Pablo, Andres A.; Alarfaj, Meshal K.; Li, Erqiang; Hernandez Sanchez, Jose Federico; Thoroddsen, Sigurdur T

    2017-01-01

    We demonstrate the viability of using four low-cost smartphone cameras to perform Tomographic PIV. We use colored shadows to imprint two or three different time-steps on the same image. The back-lighting is accomplished with three sets

  14. A Pixel-Encoder Retinal Ganglion Cell with Spatially Offset Excitatory and Inhibitory Receptive Fields

    Directory of Open Access Journals (Sweden)

    Keith P. Johnson

    2018-02-01

    Full Text Available The spike trains of retinal ganglion cells (RGCs are the only source of visual information to the brain. Here, we genetically identify an RGC type in mice that functions as a pixel encoder and increases firing to light increments (PixON-RGC. PixON-RGCs have medium-sized dendritic arbors and non-canonical center-surround receptive fields. From their receptive field center, PixON-RGCs receive only excitatory input, which encodes contrast and spatial information linearly. From their receptive field surround, PixON-RGCs receive only inhibitory input, which is temporally matched to the excitatory center input. As a result, the firing rate of PixON-RGCs linearly encodes local image contrast. Spatially offset (i.e., truly lateral inhibition of PixON-RGCs arises from spiking GABAergic amacrine cells. The receptive field organization of PixON-RGCs is independent of stimulus wavelength (i.e., achromatic. PixON-RGCs project predominantly to the dorsal lateral geniculate nucleus (dLGN of the thalamus and likely contribute to visual perception.

  15. Variation Theory and the Reception of Chinese Literature in the English-speaking World

    OpenAIRE

    Cao, Shunqing

    2015-01-01

    In his article "Variation Theory and Reception of Chinese Literature in the English-Speaking World" Shunqing Cao introduces "variation theory" he developed and suggests that the framework can be applied in studying the dissemination and reception of Chinese literature in the English-speaking world. Cao argues that cultural and literary differences produce variations in literary exchanges among different cultures and variation theory concentrates on these variations. With unique perspectives o...

  16. The robustness of two tomography reconstructing techniques with heavily noisy dynamical experimental data from a high speed gamma-ray tomograph

    International Nuclear Information System (INIS)

    Vasconcelos, Geovane Vitor; Melo, Silvio de Barros; Dantas, Carlos Costa; Moreira, Icaro Malta; Johansen, Geira; Maad, Rachid

    2013-01-01

    The PSIRT (Particle Systems Iterative Reconstructive Technique) is, just like the ART method, an iterative tomographic reconstruction technique with the recommended use in the reconstruction of catalytic density distribution in the refining process of oil in the FCC-type riser. The PSIRT is based upon computer graphics' particle systems, where the reconstructing material is initially represented as composed of particles subject to a force field emanating from the beams, whose intensities are parameterized by the differences between the experimental readings of a given beam trajectory, and the values corresponding to the current amount of particles landed in this trajectory. A dynamical process is set as the beams fields of attracting forces dispute the particles. At the end, with the equilibrium established, the particles are replaced by the corresponding regions of pixels. The High Speed Gamma-ray Tomograph is a 5-source-fan-beam device with a 17-detector deck per source, capable of producing up to a thousand complete sinograms per second. Around 70.000 experimental sinograms from this tomograph were produced simulating the move of gas bubbles in different angular speeds immersed in oil within the vessel, through the use of a two-hole-polypropylene phantom. The sinogram frames were set with several different detector integration times. This article studies and compares the robustness of both ART and PSIRT methods in this heavily noisy scenario, where this noise comes not only from limitations in the dynamical sampling, but also from to the underlying apparatus that produces the counting in the tomograph. These experiments suggest that PSIRT is a more robust method than ART for noisy data. Visual inspection on the resulting images suggests that PSIRT is a more robust method than ART for noisy data, since it almost never presents globally scattered noise. (author)

  17. Sibship size, sibling cognitive sensitivity, and children's receptive vocabulary.

    Science.gov (United States)

    Prime, Heather; Pauker, Sharon; Plamondon, André; Perlman, Michal; Jenkins, Jennifer

    2014-02-01

    The aim of the current study was to examine the relationship between sibship size and children's vocabulary as a function of quality of sibling interactions. It was hypothesized that coming from a larger sibship (ie, 3+ children) would be related to lower receptive vocabulary in children. However, we expected this association to be moderated by the level of cognitive sensitivity shown by children's next-in-age older siblings. Data on 385 children (mean age = 3.15 years) and their next-in-age older siblings (mean age = 5.57 years) were collected and included demographic questionnaires, direct testing of children's receptive vocabulary, and videos of mother-child and sibling interactions. Sibling dyads were taped engaging in a cooperative building task and tapes were coded for the amount of cognitive sensitivity the older sibling exhibited toward the younger sibling. Hierarchical regression analyses were conducted and showed an interaction between sibship size and sibling cognitive sensitivity in the prediction of children's receptive vocabulary; children exposed to large sibships whose next-in-age older sibling exhibited higher levels of cognitive sensitivity were less likely to show low vocabulary skills when compared with those children exposed to large sibships whose siblings showed lower levels of cognitive sensitivity. Children who show sensitivity to the cognitive needs of their younger siblings provide a rich environment for language development. The negative impact of large sibships on language development is moderated by the presence of an older sibling who shows high cognitive sensitivity.

  18. IceBridge Radar L3 Tomographic Ice Thickness V001

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains Level-3 tomographic ice thickness measurements derived from data captured by the Center for Remote Sensing of Ice Sheets (CReSIS) Multichannel...

  19. Control and reception of out of use radioactive sources at the CDTN/CNEN, Minas Gerais, Brazil

    International Nuclear Information System (INIS)

    Reis, Luiz C.A.; Guzella, Marcia F.R.; Seles, Sandro R.N.; Cuccia, Valeria

    2011-01-01

    For reception of the received sources and for accomplish with CNEN regulations and IAEA recommendations, the CDTN have implanted a system for receiving those sources and all the procedures for effective control and recovering of information. The CDTN posses a source deposit, a data bank for the inventory and also a Laboratory for Treatment of Sealed Sources

  20. Research for obtaining a detection system with high spatial and temporal resolution for a tomograph with positron emission (PET-Tomography)

    International Nuclear Information System (INIS)

    Cruceru, Ilie; Bartos, Daniel; Stanescu, Daniela

    2002-01-01

    This report describes a new type of detector for a tomograph system with positron emission. The detector has a new design with detection characteristics better than other detectors used currently in tomographic systems. We have in view the detectors like NaI(Tl), CsI(Tl), BGO and others. The new detector is based on discharge in gases and the interaction of gamma radiation - generated in the annihilation processes of positrons - with the mixture of gases within detector. The main novelty is the structure of electrodes with central readout microstrip plate. This structure is composed from two identical chambers. Each of these chambers have two glass resistive electrodes and one metallic electrode (cathode). One of the glass electrodes is separated from the metallic electrode while the other one is in contact with the central readout microstrip plate. In this way to gaps of 0.3 mm are generated. The gas mixture flows between these gaps. The electric charges generated in this gas are collected on the strips under the influence of the electric field applied between cathode and the anode of the detector.The arrangement of electrodes is shown. The structure of electrodes is mounted into a metallic box of special construction which allows the gas to flow through the detector and collects the electric charges generated in the detector. At present the detector is in the stage of a laboratory model and the tests carried out led to the following detection parameters: detection efficiency, 95%; spatial resolution, 3 mm; time resolution, 82 ps. The measurements were performed in coincidence using two similar detectors and the source of positrons was located between detectors. In the next stage of research will be defined the final constructive solution of the experimental model, built and tested for this positron source. The mixture of gases used for tests contained 85%C 2 H 2 F 4 + 10%SF 6 + 5%C 4 H 10 (isobutane). (authors)

  1. Structure of receptive fields in a computational model of area 3b of primary sensory cortex.

    Science.gov (United States)

    Detorakis, Georgios Is; Rougier, Nicolas P

    2014-01-01

    In a previous work, we introduced a computational model of area 3b which is built upon the neural field theory and receives input from a simplified model of the index distal finger pad populated by a random set of touch receptors (Merkell cells). This model has been shown to be able to self-organize following the random stimulation of the finger pad model and to cope, to some extent, with cortical or skin lesions. The main hypothesis of the model is that learning of skin representations occurs at the thalamo-cortical level while cortico-cortical connections serve a stereotyped competition mechanism that shapes the receptive fields. To further assess this hypothesis and the validity of the model, we reproduced in this article the exact experimental protocol of DiCarlo et al. that has been used to examine the structure of receptive fields in area 3b of the primary somatosensory cortex. Using the same analysis toolset, the model yields consistent results, having most of the receptive fields to contain a single region of excitation and one to several regions of inhibition. We further proceeded our study using a dynamic competition that deeply influences the formation of the receptive fields. We hypothesized this dynamic competition to correspond to some form of somatosensory attention that may help to precisely shape the receptive fields. To test this hypothesis, we designed a protocol where an arbitrary region of interest is delineated on the index distal finger pad and we either (1) instructed explicitly the model to attend to this region (simulating an attentional signal) (2) preferentially trained the model on this region or (3) combined the two aforementioned protocols simultaneously. Results tend to confirm that dynamic competition leads to shrunken receptive fields and its joint interaction with intensive training promotes a massive receptive fields migration and shrinkage.

  2. Structure of Receptive Fields in a Computational Model of Area 3b of Primary Sensory Cortex

    Directory of Open Access Journals (Sweden)

    Georgios eDetorakis

    2014-07-01

    Full Text Available In a previous work, we introduced a computational model of area 3b which is built upon the neural field theory and receives input from a simplified model of the index distal finger pad populated by a random set of touch receptors(Merkell cells. This model has been shown to be able to self-organize following the random stimulation of the finger pad model and to cope, to some extent, with cortical or skin lesions. The main hypothesis of the model is that learning of skin representations occurs at the thalamo-cortical level while cortico-cortical connections serve a stereotyped competition mechanism that shapes the receptive fields. To further assess this hypothesis and the validity of the model, we reproduced in this article the exact experimental protocol of DiCarlo et al. that has been used to examine the structure of receptive fields in area 3b of the primary somatosensory cortex. Using the same analysis toolset, the model yields consistent results, having most of the receptive fields to contain a single region of excitation and one to severalregions of inhibition. We further proceeded our study using a dynamic competition that deeply influences the formation of the receptive fields. We hypothesized this dynamic competition to correspond to some form of somatosensory attention that may help to precisely shape the receptive fields. To test this hypothesis, we designed a protocol where an arbitrary region of interest is delineated on the index distal finger pad and we either (1 instructed explicitly the model to attend to this region (simulating an attentional signal (2 preferentially trained the model on this region or (3combined the two aforementioned protocols simultaneously. Results tend to confirm that dynamic competition leads to shrunken receptive fields and its joint interaction with intensive training promotes a massive receptive fields migration and shrinkage.

  3. A new algorithm for γ-ray tomographic imaging using a scintillation camera

    International Nuclear Information System (INIS)

    Terajima, Hirokatsu; Nakajima, Masato; Itoh, Takashi.

    1979-01-01

    The gamma ray tomographic imaging giving 3-dimensional distribution of RI in human bodies is being actively investigated for the reason that the conventional images are of 2-dimensional projection, but it is not yet employed practically, because there are some problems in the tomographic image quality obtained. One of the methods is a technique to determine the radioisotope distribution on each tomographic plane by placing a planar detector in parallel with the assumed tomographic planes and by processing the 2-dimensional radioisotope projection images thus obtained. It does not require the repetition of reconstructive algorithm. The authors have proposed the algorithm for this method, and have carried out the experiments to verify the propriety of the algorithm. Radioisotope phantom is composed of the overlapping acrylic cubic vessels of 30 mm sides containing radioisotopes arranged 2-dimensionally in each layer, and the multi-pinhole shutter array is used as the collimator. The projection image of radioisotope distribution on the scintillator face is converted into the digital imaging data sampled in 2-dimensional space of 64 x 64 with the mini-computer. Among the probable causes to affect the reconstructed image quality, statistical fluctuation, absorption of gamma ray and the shape of aperture for the collimator are discussed. These indicate that this method is more effective than the conventional methods, and can be the effective technique for medical diagnosis and therapy, because this is a technique to determine 3-dimensional distribution of RI by utilizing existing equipments. (Wakatsuki, Y.)

  4. An intragastric trichobezoar: computerised tomographic appearance.

    Directory of Open Access Journals (Sweden)

    Morris B

    2000-04-01

    Full Text Available A 26-year-old lady presented with a history of abdominal pain and distension since two months. The ultrasound examination showed an epigastric mass, which was delineated as a filling defect in the stomach on barium studies. The computerised tomographic scan showed a gastric mass with pockets of air in it, without post-contrast enhancement. This case highlights the characteristic appearance on computerised tomography of a bezoar within the stomach, a feature that is not commonly described in medical literature.

  5. Collimator trans-axial tomographic scintillation camera

    International Nuclear Information System (INIS)

    Jaszczak, Ronald J.

    1979-01-01

    An improved collimator is provided for a scintillation camera system that employs a detector head for transaxial tomographic scanning. One object of this invention is to significantly reduce the time required to obtain statistically significant data in radioisotope scanning using a scintillation camera. Another is to increase the rate of acceptance of radioactive events to contribute to the positional information obtainable from a radiation source of known strength without sacrificing spatial resolution. A further object is to reduce the necessary scanning time without degrading the images obtained. The collimator described has apertures defined by septa of different radiation transparency. The septa are aligned to provide greater radiation shielding from gamma radiation travelling within planes perpendicular to the cranial-caudal axis and less radiation shielding from gamma radiation travelling within other planes. Septa may also define apertures such that the collimator provides high spatial resolution of gamma rays traveling within planes perpendicular to the cranial-caudal axis and directed at the detector and high radiation sensitivity to gamma radiation travelling other planes and indicated at the detector. (LL)

  6. Generation and reception of spread-spectrum signals

    Science.gov (United States)

    Moser, R.

    1983-05-01

    The term 'spread-spectrum' implies a technique whereby digitized information is added to a pseudo-random number sequence and the resultant bit stream changes some parameter of the carrier frequency in discrete increments. The discrete modulation of the carrier frequency is usually realized either as a multiple level phase shift keyed or frequency shift keyed signal. The resultant PSK-modulated frequency spectrum is referred to as direct sequence spread-spectrum, whereas the FSK-modulated carrier frequency is referred to as a frequency hopped spread spectrum. These can be considered the major subsets of the more general term 'spread-spectrum'. In discussing signal reception, it is pointed out that active correlation methods are used for channel synchronization when the psuedo random sequences are long or when the processing gain is large, whereas the passive methods may be used for either short pseudo-random noise generation codes or to assist in attaining initial synchronization in long sequence spread-spectrum systems.

  7. Lamb-Wave-Based Tomographic Imaging Techniques for Hole-Edge Corrosion Monitoring in Plate Structures

    Directory of Open Access Journals (Sweden)

    Dengjiang Wang

    2016-11-01

    Full Text Available This study presents a novel monitoring method for hole-edge corrosion damage in plate structures based on Lamb wave tomographic imaging techniques. An experimental procedure with a cross-hole layout using 16 piezoelectric transducers (PZTs was designed. The A0 mode of the Lamb wave was selected, which is sensitive to thickness-loss damage. The iterative algebraic reconstruction technique (ART method was used to locate and quantify the corrosion damage at the edge of the hole. Hydrofluoric acid with a concentration of 20% was used to corrode the specimen artificially. To estimate the effectiveness of the proposed method, the real corrosion damage was compared with the predicted corrosion damage based on the tomographic method. The results show that the Lamb-wave-based tomographic method can be used to monitor the hole-edge corrosion damage accurately.

  8. Online Movie Trailers - A Reception Analysis

    OpenAIRE

    Jensen, Frida Videbæk; Rozé, Caroline

    2014-01-01

    This project is a reception analysis of how a target group receive online movie trailers. It utilized a focus group as means of research with participants from the dormitories Kollibrien and Korallen. We concluded that the group we investigated were not interested in online movie trailers as anything else than a preview of a movie. They preferred to experience movie trailers in the cinema. Their opinion of specific movie trailers were also determined by whether or not they identified with the...

  9. Computed tomographic evaluation of the altered pancreas in dog and cat

    International Nuclear Information System (INIS)

    Posch, B.

    2002-11-01

    Eighteen dogs and 12 cats of varying breed, age and sex underwent a computed tomographic study of the pancreas. Length, diameter and density of each lobe of the pancreas were measured. Further, the gained results were compared to the information established by the clinical examination, sonography, haematology and histology. Contrast CT improved evaluation of the pancreas in all cases of normal life controls. CT criteria such as changes in size, density, delimitation of the pancreas and the peripancreatic structures were analyzed. Increased pancreatic size was seen in inflammatory as well as in neoplastic diseases. There were no reliable computed tomographic criteria to differentiate pancreatic neoplasia from inflammation without peripancreatic findings. Ultrasonography proved to be a good screening method in this study: sonographic and computed tomographic results correlated in all cases with the exception of 5 cases. In contrast to ultrasonography CT could differentiate normal pancreas from pancreas atrophy. Computed tomography was superior to sonography in determining the full extent of pancreatic and peripancreatic signs due to the good overview and overall image of the abdominal structures. Serum chemistry of a- amylase and lipase were obtained in 28 animals. Assays of serum lipase and a- amylase activities were only able to detect acute pancreatitis in half of the canine cases. Despite morphological alterations detected with the help of sonography or CT, there were no significant increases in a- amylase and lipase in cats. Following computed tomography the pancreas of 10 animals was examined pathohistologically. With the exception of 2 cases the computed tomographic results correlated with the pathohistological findings. In conclusion, computed tomography (CT) proved to be a valuable method to evaluate the localization, the full extent and the seriousness of pancreatic lesions. (author)

  10. Pre-adolescent Receptivity to Tobacco Marketing and Its Relationship to Acquiring Friends Who Smoke and Cigarette Smoking Initiation.

    Science.gov (United States)

    Strong, David R; Messer, Karen; Hartman, Sheri J; Nodora, Jesse; Vera, Lisa; White, Martha M; Leas, Eric; Pharris-Ciurej, Nikolas; Borek, Nicolette; Pierce, John P

    2017-10-01

    This study extends research on receptivity to tobacco marketing over a key developmental period for cigarette smoking experimentation. The purpose of this study was to understand the effect of receptivity to tobacco marketing and exposure to friends who smoke on smoking experimentation. Participants were 10 to 13 years old who had never tried cigarettes (n = 878), interviewed six times at 8-month intervals. At baseline, 25% percent of the 10 and 11 years old in the sample of never smokers were receptive to tobacco marketing, while less than 5% had friends who smoked. Having a friend who smoked at study baseline and acquiring such friends for the first time during the study were the strongest predictors of smoking experimentation. Initial receptivity to tobacco marketing increased the risk of smoking experimentation independently of having friends who smoke at baseline or acquiring friends who smoke throughout the study period. The high level of receptivity observed even among 10 and 11 years old and its robust relationship with cigarette smoking experimentation independent of the significant risk associated with having friends who smoke suggests that successful prevention of receptivity may require intervention at an early age.

  11. An original emission tomograph for in vivo brain imaging of small animals

    International Nuclear Information System (INIS)

    Ochoa, A.V.; Ploux, L.; Mastrippolito, R.

    1996-01-01

    The principle of a new tomograph TOHR dedicated for small volume analysis with very high resolution is presented in this paper. We use uncorrelated multi-photons (X or gamma rays) radioisotopes and a large solid angle focusing collimator to make tomographic imaging without reconstruction algorithm. With this original device, detection efficiency and resolution are independent and submillimetric resolution can be achieved. A feasibility study shows that, made achieve the predicted performances of TOHR. We discuss its potential in rat brain tomography by simulating a realistic neuropharmacological experiment using a 1.4 mm resolution prototype of TOHR under development

  12. Adapting a receptive vocabulary test for preschool-aged Greek-speaking children.

    Science.gov (United States)

    Okalidou, Areti; Syrika, Asimina; Beckman, Mary E; Edwards, Jan R

    2011-01-01

    Receptive vocabulary is an important measure for language evaluations. Therefore, norm-referenced receptive vocabulary tests are widely used in several languages. However, a receptive vocabulary test has not yet been normed for Modern Greek. To adapt an American English vocabulary test, the Receptive One-Word Picture Vocabulary Test-II (ROWPVT-II), for Modern Greek for use with Greek-speaking preschool children. The list of 170 English words on ROWPVT-II was adapted by (1) developing two lists (A and B) of Greek words that would match either the target English word or another concept corresponding to one of the pictured objects in the four-picture array; and (2) determining a developmental order for the chosen Greek words for preschool-aged children. For the first task, adult word frequency measures were used to select the words for the Greek wordlist. For the second task, 427 children, 225 boys and 202 girls, ranging in age from 2;0 years to 5;11 years, were recruited from urban and suburban areas of Greece. A pilot study of the two word lists was performed with the aim of comparing an equal number of list A and list B responses for each age group and deriving a new developmental list order. The relative difficulty of each Greek word item, that is, its accuracy score, was calculated by taking the average proportion of correct responses across ages for that word. Subsequently, the word accuracy scores in the two lists were compared via regression analysis, which yielded a highly significant relationship (R(2) = 0.97; p word item from the two lists was a better fit. Finally, new starting levels (basals) were established for preschool ages. The revised word list can serve as the basis for adapting a receptive vocabulary test for Greek preschool-aged children. Further steps need to be taken when testing larger numbers of 2;0 to 5;11-year-old children on the revised word list for determination of norms. This effort will facilitate early identification and remediation

  13. How do psychological factors influence adolescent smoking progression? The evidence for indirect effects through tobacco advertising receptivity.

    Science.gov (United States)

    Audrain-McGovern, Janet; Rodriguez, Daniel; Patel, Vaishali; Faith, Myles S; Rodgers, Kelli; Cuevas, Jocelyn

    2006-04-01

    To determine whether novelty seeking and depressive symptoms had mediated or indirect effects on adolescent smoking progression through tobacco advertising receptivity. More than 1000 adolescents were monitored from 9th grade to 12th grade and completed annual surveys that measured demographic characteristics, smoking behavior, tobacco advertising receptivity, novelty-seeking personality, depressive symptoms, family and peer smoking, alcohol use, and marijuana use. Latent growth modeling indicated that novelty seeking had a significant indirect effect on smoking progression through baseline tobacco advertising receptivity. For each 1-SD increase in novelty seeking, the odds of being more receptive to tobacco advertising increased by 12% (ie, being in a specific category or higher), which in turn resulted in an 11% increase in the odds of smoking progression from 9th grade to 12th grade. The indirect effect from depressive symptoms to smoking progression did not reach significance. These findings may inform future research on other factors that influence tobacco advertising receptivity, as well as programs aimed at preventing adolescent smoking initiation and progression.

  14. From Iser to Turner and beyond: reception theory meets cognitive criticism

    Directory of Open Access Journals (Sweden)

    Craig Hamilton

    2012-01-01

    Full Text Available In this essay, we review the work of Wolfgang Iser, the major proponent of reception theory, and Mark Turner, the major proponent of cognitive criticism. The two theoretical lines advocated by Iser and Turner focus on the cognitive processes involved with reading literary texts. Unfortunately, bibliographic blind spots in both lines lead to the assumption that there is little overlap between reception theory and cognitive criticism. We put this assumption to rest by comparing and contrasting works by Iser and Turner in detail, starting with Iser’s work in the mid-1970s and ending with Turner’s work in the late 1990s.

  15. Mapping the receptivity of malaria risk to plan the future of control in Somalia

    Science.gov (United States)

    Alegana, Victor Adagi; Patil, Anand Prabhakar; Moloney, Grainne; Borle, Mohammed; Yusuf, Fahmi; Amran, Jamal; Snow, Robert William

    2012-01-01

    Objectives To measure the receptive risks of malaria in Somalia and compare decisions on intervention scale-up based on this map and the more widely used contemporary risk maps. Design Cross-sectional community Plasmodium falciparum parasite rate (PfPR) data for the period 2007–2010 corrected to a standard age range of 2 to Somalia. Participants Randomly sampled individuals of all ages. Main outcome measure Cartographic descriptions of malaria receptivity and contemporary risks in Somalia at the district level. Results The contemporary annual PfPR2–10 map estimated that all districts (n=74) and population (n=8.4 million) in Somalia were under hypoendemic transmission (≤10% PfPR2–10). Of these, 23% of the districts, home to 13% of the population, were under transmission of 10%–50% PfPR2–10) and the rest as hypoendemic. Conclusion Compared with maps of receptive risks, contemporary maps of transmission mask disparities of malaria risk necessary to prioritise and sustain future control. As malaria risk declines across Africa, efforts must be invested in measuring receptivity for efficient control planning. PMID:22855625

  16. The effectiveness of correcting codes in reception in the whole in additive normal white noise

    Science.gov (United States)

    Shtarkov, Y. M.

    1974-01-01

    Some possible criteria for estimating the effectiveness of correcting codes are presented, and the energy effectiveness of correcting codes is studied for symbol-by-symbol reception. Expressions for the energetic effectiveness of binary correcting codes for reception in the whole are produced. Asymptotic energetic effectiveness and finite signal/noise ratio cases are considered.

  17. Vocabulary and Receptive Knowledge of English Collocations among Swedish Upper Secondary School Students

    OpenAIRE

    Bergström, Kerstin

    2008-01-01

    The aim of this study is to examine the vocabulary and receptive collocation knowledge in English among Swedish upper secondary school students. The primary material consists of two vocabulary tests, one collocation test, and a background questionnaire. The first research question concerns whether the students who receive a major part of their education in English have a higher level of vocabulary and receptive collocation knowledge in English than those who are taught primarily in Swedish. T...

  18. From tomographic images to fault heterogeneities

    Directory of Open Access Journals (Sweden)

    A. Amato

    1994-06-01

    Full Text Available Local Earthquake Tomography (LET is a useful tool for imaging lateral heterogeneities in the upper crust. The pattern of P- and S-wave velocity anomalies, in relation to the seismicity distribution along active fault zones. can shed light on the existence of discrete seismogenic patches. Recent tomographic studies in well monitored seismic areas have shown that the regions with large seismic moment release generally correspond to high velocity zones (HVZ's. In this paper, we discuss the relationship between the seismogenic behavior of faults and the velocity structure of fault zones as inferred from seismic tomography. First, we review some recent tomographic studies in active strike-slip faults. We show examples from different segments of the San Andreas fault system (Parkfield, Loma Prieta, where detailed studies have been carried out in recent years. We also show two applications of LET to thrust faults (Coalinga, Friuli. Then, we focus on the Irpinia normal fault zone (South-Central Italy, where a Ms = 6.9 earthquake occurred in 1980 and many thousands of attershock travel time data are available. We find that earthquake hypocenters concentrate in HVZ's, whereas low velocity zones (LVZ’ s appear to be relatively aseismic. The main HVZ's along which the mainshock rupture bas propagated may correspond to velocity weakening fault regions, whereas the LVZ's are probably related to weak materials undergoing stable slip (velocity strengthening. A correlation exists between this HVZ and the area with larger coseismic slip along the fault, according to both surface evidence (a fault scarp as high as 1 m and strong ground motion waveform modeling. Smaller wave-length, low-velocity anomalies detected along the fault may be the expression of velocity strengthening sections, where aseismic slip occurs. According to our results, the rupture at the nucleation depth (~ 10-12 km is continuous for the whole fault lenoth (~ 30 km, whereas at shallow depth

  19. The effects of echolalia on acquisition and generalization of receptive labeling in autistic children.

    OpenAIRE

    Charlop, M H

    1983-01-01

    This investigation, consisting of two experiments, was designed to assess the effects of autistic immediate echolalia on acquisition and generalization of receptive labeling tasks. Experiment 1 addressed whether autistic children could use their echolalia to facilitate acquisition. The results indicated that incorporating echolalia (echo of the requested object's label) into the task before manual response (handing the requested object to the experimenter) facilitated receptive labeling. Expe...

  20. Line-scanning tomographic optical microscope with isotropic transfer function

    International Nuclear Information System (INIS)

    Gajdátsy, Gábor; Dudás, László; Erdélyi, Miklós; Szabó, Gábor

    2010-01-01

    An imaging method and optical system, referred to as a line-scanning tomographic optical microscope (LSTOM) using a combination of line-scanning technique and CT reconstruction principle, is proposed and studied theoretically and experimentally. In our implementation a narrow focus line is scanned over the sample and the reflected light is measured in a confocal arrangement. One such scan is equivalent to a transverse projection in tomography. Repeating the scanning procedure in several directions, a number of transverse projections are recorded from which the image can be obtained using conventional CT reconstruction algorithms. The resolution of the image is independent of the spatial dimensions and structure of the applied detector; furthermore, the transfer function of the system is isotropic. The imaging performance of the implemented confocal LSTOM was compared with a point-scanning confocal microscope, based on recorded images. These images demonstrate that the resolution of the confocal LSTOM exceeds (by 15%) the resolution limit of a point-scanning confocal microscope

  1. Clinical investigations of receptive and expressive musical functions after stroke

    Directory of Open Access Journals (Sweden)

    Ken eRosslau

    2015-06-01

    Full Text Available There is a long tradition of investigating various disorders of musical abilities after stroke. These impairments, associated with acquired amusia, can be highly selective, affecting only music perception (i.e., receptive abilities/functions or expression (music production abilities, and some patients report that these may dramatically influence their emotional state. The aim of this study was to systematically test both the melodic and rhythmic domains of music perception and expression in left- and right-sided stroke patients compared to healthy subjects. Music perception was assessed using rhythmic and melodic discrimination tasks, while tests of expressive function involved the vocal or instrumental reproduction of rhythms and melodies. Our approach revealed deficits in receptive and expressive functions in stroke patients, mediated by musical expertise. Those patients who had experienced a short period of musical training in childhood and adolescence performed better in the receptive and expressive subtests compared to those without any previous musical training. While discrimination of specific musical patterns was unimpaired after a right-sided stroke, patients with a left-sided stroke had worse results for fine melodic and rhythmic analysis. In terms of expressive testing, the most consistent results were obtained from a test that required patients to reproduce sung melodies. This implies that the means of investigating production abilities can impact the identification of deficits.

  2. Clinical investigations of receptive and expressive musical functions after stroke.

    Science.gov (United States)

    Rosslau, Ken; Steinwede, Daniel; Schröder, C; Herholz, Sibylle C; Lappe, Claudia; Dobel, Christian; Altenmüller, Eckart

    2015-01-01

    There is a long tradition of investigating various disorders of musical abilities after stroke. These impairments, associated with acquired amusia, can be highly selective, affecting only music perception (i.e., receptive abilities/functions) or expression (music production abilities), and some patients report that these may dramatically influence their emotional state. The aim of this study was to systematically test both the melodic and rhythmic domains of music perception and expression in left- and right-sided stroke patients compared to healthy subjects. Music perception was assessed using rhythmic and melodic discrimination tasks, while tests of expressive function involved the vocal or instrumental reproduction of rhythms and melodies. Our approach revealed deficits in receptive and expressive functions in stroke patients, mediated by musical expertise. Those patients who had experienced a short period of musical training in childhood and adolescence performed better in the receptive and expressive subtests compared to those without any previous musical training. While discrimination of specific musical patterns was unimpaired after a left-sided stroke, patients with a right-sided stroke had worse results for fine melodic and rhythmic analysis. In terms of expressive testing, the most consistent results were obtained from a test that required patients to reproduce sung melodies. This implies that the means of investigating production abilities can impact the identification of deficits.

  3. Receptivity to protobacco media and its impact on cigarette smoking among ethnic minority youth in California.

    Science.gov (United States)

    Chen, Xinguang; Cruz, Tess Boley; Schuster, Darleen V; Unger, Jennifer B; Johnson, Carl Anderson

    2002-01-01

    Adolescents from different ethnic groups show different cigarette smoking prevalence rates, suggesting potential differences in receptivity to and influences from protobacco media. Understanding these differences will be helpful in tailoring smoking prevention and cessation programs for diverse adolescent populations in the United States. Data from cross-sectional surveys of 20,332 randomly sampled California boys and girls, 12-17 years of age, were analyzed. Results indicate that receptivity to protobacco media was lower among African Americans, Asian Americans, and Hispanics than among White youth. There was a consistent dose-response relationship between receptivity to protobacco media and 30-day cigarette smoking across ethnic groups. Having a cigarette brand preference was associated with the highest risk for cigarette smoking, having a favorite tobacco ad showed the lowest risk, while having received or being willing to use tobacco promotional items was associated with a moderate risk. After controlling for 13 covariates, the odds ratio for receptivity to protobacco media and 30-day cigarette smoking was significant for Whites (RR = 1.38, p 0.05) and Asian American (RR = 1.17, p > 0.05) youth. African American, Asian American, and Hispanic adolescents have a lower level of receptivity to protobacco media than do Whites. The association between media receptivity and 30-day cigarette smoking exists for all four ethnic groups without controlling for other smoking predictor variables, but only for Hispanics and Whites when other variables are controlled. Protecting adolescents from protobacco advertising influences is an important element in tobacco control among ethnic minority youth.

  4. Receptivity to Kinetic Fluctuations: A Multiple Scales Approach

    Science.gov (United States)

    Edwards, Luke; Tumin, Anatoli

    2017-11-01

    The receptivity of high-speed compressible boundary layers to kinetic fluctuations (KF) is considered within the framework of fluctuating hydrodynamics. The formulation is based on the idea that KF-induced dissipative fluxes may lead to the generation of unstable modes in the boundary layer. Fedorov and Tumin solved the receptivity problem using an asymptotic matching approach which utilized a resonant inner solution in the vicinity of the generation point of the second Mack mode. Here we take a slightly more general approach based on a multiple scales WKB ansatz which requires fewer assumptions about the behavior of the stability spectrum. The approach is modeled after the one taken by Luchini to study low speed incompressible boundary layers over a swept wing. The new framework is used to study examples of high-enthalpy, flat plate boundary layers whose spectra exhibit nuanced behavior near the generation point, such as first mode instabilities and near-neutral evolution over moderate length scales. The configurations considered exhibit supersonic unstable second Mack modes despite the temperature ratio Tw /Te > 1 , contrary to prior expectations. Supported by AFOSR and ONR.

  5. Tomographic anthropomorphic models. Pt. 1

    International Nuclear Information System (INIS)

    Veit, R.; Zankl, M.; Petoussi, N.; Mannweiler, E.; Drexler, G.; Williams, G.

    1989-01-01

    The first generation of heterogenoeous anthropomorphic mathematical models to be used in dose calculations was the MIRD-5 adult phantom, followed by the pediatric MIRD-type phantoms and by the GSF sex-specific phantoms ADAM and EVA. A new generation of realistic anthropomorphic models is now introduced. The organs and tissues of these models consist of a well defined number of volume elements (voxels), derived from computer tomographic (CT) data; consequently, these models were named voxel or tomographic models. So far two voxel models of real patients are available: one of an 8 week old baby and of a 7 year old child. For simplicity, the model of the baby will be referred to as BABY and that of the child as CHILD. In chapter 1 a brief literature review is given on the existing mathematical models and their applications. The reasons that lead to the construction of the new CT models is discussed. In chapter 2 the technique is described which allows to convert any physical object into computer files to be used for dose calculations. The technique which produces three dimensional reconstructions of high resolution is discussed. In chapter 3 the main characteristics of the models of the baby and child are given. Tables of organ masses and volumes are presented together with three dimensional images of some organs and tissues. A special mention is given to the assessment of bone marrow distribution. Chapter 4 gives a short description of the Monte Carlo code used in conjunction with the models to calculate organ and tissue doses resulting from photon exposures. Some technical details concerning the computer files which describe the models are also given. (orig./HP)

  6. Nonlinear absorption and receptivity of the third order in InAs infrared region

    International Nuclear Information System (INIS)

    Musayev, M.A.

    2005-01-01

    Nonlinear absorption and receptivity of the third order and coefficient nonlinear absorption in InAs n-type with different degree of alloying was measured. Obtained score considerably exceed sense, calculated on the basis of the models describing nonlinear receptivity of electrons, situated in the nonparabolic area of conductivity. It was shown that, observable deviations withdraw; if in the calculation apply energy dissipation of electrons. Growth of the efficiency under four-wave interaction in low-energy-gap semiconductors confines nonlinear absorption of interacting waves

  7. Computer tomographic examinations in epilepsy

    International Nuclear Information System (INIS)

    De Villiers, J.F.K.

    1984-01-01

    Epileptic patients that was examined at the Universitas Hospital (Bloemfontein) by means of computerized tomography for the period July 1978 - December 1980, are divided into two groups: a) Patients with general epilepsy of convulsions - 507; b) Patients with vocal or partial epilepsy - 111. The method of examination and the results for both general and vocal epilepsy are discussed. A degenerative state was found in 35% of the positive computer tomographic examinations in general epilepsy and 22% of the positive examinations for vocal epilepsy. The purpose of the article was to explain the circumstances that can be expected when a epileptic patient is examined by means of computerized tomography

  8. Ovarian metastases: Computed tomographic appearances

    International Nuclear Information System (INIS)

    Megibow, A.J.; Hulnick, D.H.; Bosniak, M.A.; Balthazar, E.J.

    1985-01-01

    Computed tomographic scans of 34 patients with ovarian metastases were reviewed to assess the radiographic appearances and to correlate these with the primary neoplasms. Primary neoplasms were located in the colon (20 patients), breast (six), stomach (five), small bowel (one), bladder (one), and Wilms tumor of the kidney (one). The radiographic appearance of the metastatic lesions could be described as predominantly cystic (14 lesions), mixed (12 lesions), or solid (seven lesions). The cystic and mixed lesions tended to be larger in overall diameter than the solid. The metastases from gastric carcinoma appeared solid in four of five cases. The metastases from the other neoplasms had variable appearances simulating primary ovarian carcinoma

  9. Investigating Gravity Waves in Polar Mesospheric Clouds Using Tomographic Reconstructions of AIM Satellite Imagery

    Science.gov (United States)

    Hart, V. P.; Taylor, M. J.; Doyle, T. E.; Zhao, Y.; Pautet, P.-D.; Carruth, B. L.; Rusch, D. W.; Russell, J. M.

    2018-01-01

    This research presents the first application of tomographic techniques for investigating gravity wave structures in polar mesospheric clouds (PMCs) imaged by the Cloud Imaging and Particle Size instrument on the NASA AIM satellite. Albedo data comprising consecutive PMC scenes were used to tomographically reconstruct a 3-D layer using the Partially Constrained Algebraic Reconstruction Technique algorithm and a previously developed "fanning" technique. For this pilot study, a large region (760 × 148 km) of the PMC layer (altitude 83 km) was sampled with a 2 km horizontal resolution, and an intensity weighted centroid technique was developed to create novel 2-D surface maps, characterizing the individual gravity waves as well as their altitude variability. Spectral analysis of seven selected wave events observed during the Northern Hemisphere 2007 PMC season exhibited dominant horizontal wavelengths of 60-90 km, consistent with previous studies. These tomographic analyses have enabled a broad range of new investigations. For example, a clear spatial anticorrelation was observed between the PMC albedo and wave-induced altitude changes, with higher-albedo structures aligning well with wave troughs, while low-intensity regions aligned with wave crests. This result appears to be consistent with current theories of PMC development in the mesopause region. This new tomographic imaging technique also provides valuable wave amplitude information enabling further mesospheric gravity wave investigations, including quantitative analysis of their hemispheric and interannual characteristics and variations.

  10. Computerized tomographic findings in children with head trauma in ...

    African Journals Online (AJOL)

    Objective: To describe the computerized tomographic findings in children with head trauma who presented at the University of Benin Teaching Hospital, Benin City, Nigeria. Methods: It is a retrospective review of patients aged 0 – 15 years with suspected intracranial injury (ICI) following head trauma, who presented for CT ...

  11. Werner Sombart and his reception in Italy

    Directory of Open Access Journals (Sweden)

    Simona Pisanelli

    2015-03-01

    Full Text Available This article intends to focus on the difficulty encountered by Werner Sombart’s works in gaining a hearing in various Italian intellectual circuits. As is well known, Sombart belonged to the German Historical School of economics, sharing with other scholars of that school the same problems in getting his work known in Italy. Our aim is to explain the reason for this hostile reception. First of all, we will analyze the factors which generally hindered the spread of the German Historical School in Italy, recognizing in economists like Francesco Ferrara, Idealists like Benedetto Croce and Marxists like Antonio Labriola some of its strongest opponents. We will dwell on the cases of Gustav Schmoller and Max Weber, in order to give two representative examples of the slow and complicated Italian reception of methodological approaches and analytical perspectives which characterized the scientific experience of the German Historical School. Secondly, we will try to show why Sombart was even less appreciated than other German social scientists, giving the reasons that attracted severe criticism from economists, economic historians and sociologists towards his interdisciplinary approach in the analysis of modern capitalism. Finally, we will show the reasons of the contemporary rediscovery of Sombart and of his works.

  12. Tomographic scanning apparatus with ionization detector means

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus using a fan beam and digital output signal. Particular reference is made to the gas-pressurized ionization detector chamber, consisting of an array of side-by-side elongate ionization detection cells, the principal axis of each of the said cells being oriented along a radius extending towards the radiation source, and connection means for applying potentials across the cells for taking their output signals. (U.K.)

  13. A review of US anthropometric reference data (1971-2000) with comparisons to both stylized and tomographic anatomic models

    International Nuclear Information System (INIS)

    Huh, C; Bolch, W E

    2003-01-01

    Two classes of anatomic models currently exist for use in both radiation protection and radiation dose reconstruction: stylized mathematical models and tomographic voxel models. The former utilize 3D surface equations to represent internal organ structure and external body shape, while the latter are based on segmented CT or MR images of a single individual. While tomographic models are clearly more anthropomorphic than stylized models, a given model's characterization as being anthropometric is dependent upon the reference human to which the model is compared. In the present study, data on total body mass, standing/sitting heights and body mass index are collected and reviewed for the US population covering the time interval from 1971 to 2000. These same anthropometric parameters are then assembled for the ORNL series of stylized models, the GSF series of tomographic models (Golem, Helga, Donna, etc), the adult male Zubal tomographic model and the UF newborn tomographic model. The stylized ORNL models of the adult male and female are found to be fairly representative of present-day average US males and females, respectively, in terms of both standing and sitting heights for ages between 20 and 60-80 years. While the ORNL adult male model provides a reasonably close match to the total body mass of the average US 21-year-old male (within ∼5%), present-day 40-year-old males have an average total body mass that is ∼16% higher. For radiation protection purposes, the use of the larger 73.7 kg adult ORNL stylized hermaphrodite model provides a much closer representation of average present-day US females at ages ranging from 20 to 70 years. In terms of the adult tomographic models from the GSF series, only Donna (40-year-old F) closely matches her age-matched US counterpart in terms of average body mass. Regarding standing heights, the better matches to US age-correlated averages belong to Irene (32-year-old F) for the females and Golem (38-year-old M) for the males

  14. Tomographic multiphase flow measurement

    Energy Technology Data Exchange (ETDEWEB)

    Saetre, C., E-mail: camilla@ift.uib.no [Department of Physics and Technology, University of Bergen (Norway); Michelsen Centre for Industrial Measurement Science and Technology (Norway); Johansen, G.A. [Department of Physics and Technology, University of Bergen (Norway); Michelsen Centre for Industrial Measurement Science and Technology (Norway); Tjugum, S.A. [Michelsen Centre for Industrial Measurement Science and Technology (Norway); Roxar Flow Measurement, Bergen (Norway)

    2012-07-15

    Measurement of multiphase flow of gas, oil and water is not at all trivial and in spite of considerable achievements over the past two decades, important challenges remain (). These are related to reducing measurement uncertainties arising from variations in the flow regime, improving long term stability and developing new means for calibration, adjustment and verification of the multiphase flow meters. This work focuses on the first two issues using multi gamma beam (MGB) measurements for identification of the type of flow regime. Further gamma ray tomographic measurements are used for reference of the gas/liquid distribution. For the MGB method one Am-241 source with principal emission at 59.5 keV is used because this relatively low energy enables efficient collimation and thereby shaping of the beams, as well as compact detectors. One detector is placed diametrically opposite the source whereas the second is positioned to the side so that this beam is close to the pipe wall. The principle is then straight forward to compare the measured intensities of these detectors and through that identify the flow pattern, i.e. the instantaneous cross-sectional gas-liquid distribution. The measurement setup also includes Compton scattering measurements, which can provide information about the changes in the water salinity for flow segments with high water liquid ratio and low gas fractions. By measuring the transmitted intensity in short time slots (<100ms), rapid regime variations are revealed. From this we can select the time sections suitable for salinity measurements. Since the salinity variations change at the time scale of hours, a running average can be performed to increase the accuracy of the measurements. Recent results of this work will be presented here. - Highlights: Black-Right-Pointing-Pointer Multiphase flow gas-fraction and flow regime measurements by multi gamma ray beams. Black-Right-Pointing-Pointer High-speed gamma ray tomograph as reference for the flow

  15. Tomographic multiphase flow measurement

    International Nuclear Information System (INIS)

    Sætre, C.; Johansen, G.A.; Tjugum, S.A.

    2012-01-01

    Measurement of multiphase flow of gas, oil and water is not at all trivial and in spite of considerable achievements over the past two decades, important challenges remain (). These are related to reducing measurement uncertainties arising from variations in the flow regime, improving long term stability and developing new means for calibration, adjustment and verification of the multiphase flow meters. This work focuses on the first two issues using multi gamma beam (MGB) measurements for identification of the type of flow regime. Further gamma ray tomographic measurements are used for reference of the gas/liquid distribution. For the MGB method one Am-241 source with principal emission at 59.5 keV is used because this relatively low energy enables efficient collimation and thereby shaping of the beams, as well as compact detectors. One detector is placed diametrically opposite the source whereas the second is positioned to the side so that this beam is close to the pipe wall. The principle is then straight forward to compare the measured intensities of these detectors and through that identify the flow pattern, i.e. the instantaneous cross-sectional gas-liquid distribution. The measurement setup also includes Compton scattering measurements, which can provide information about the changes in the water salinity for flow segments with high water liquid ratio and low gas fractions. By measuring the transmitted intensity in short time slots (<100ms), rapid regime variations are revealed. From this we can select the time sections suitable for salinity measurements. Since the salinity variations change at the time scale of hours, a running average can be performed to increase the accuracy of the measurements. Recent results of this work will be presented here. - Highlights: ► Multiphase flow gas-fraction and flow regime measurements by multi gamma ray beams. ► High-speed gamma ray tomograph as reference for the flow pattern and gas fraction. ► Dual modality

  16. Computer tomographic detection of an intraspinal arachnoidal cyst

    Energy Technology Data Exchange (ETDEWEB)

    Kuckein, D; Walter, K; Paal, G

    1981-03-01

    A 46 year old female patient who after 3-4 weeks of influenza suffered from strong headaches, vomiting and rotatory vertigo was subjected to a myelograph and then to a computerized tomographic investigation due to suspect cerebrospinal fluid. The computerized tomography is better than the myelography in diagnosing intraspinal arachnoidal cysts, however this should be preceded by most accurate possible segment location.

  17. Qualitative Audience Research: Toward an Integrative Approach to Reception.

    Science.gov (United States)

    Jensen, Klaus Bruhn

    1987-01-01

    Analyzes research about the mass communication audience and describes a theoretical and methodological framework for further empirical studies. Discusses the (1) explanatory value of qualitative research; (2) social and cultural implications of the reception process, with special reference to television; and (3) applications and social relevance…

  18. Process and installation for producing tomographic images of the distribution of a radiotracer

    International Nuclear Information System (INIS)

    Fonroget, Jacques; Brunol, Jean.

    1977-01-01

    The invention particularly concerns a process for obtaining tomographic images of an object formed by a radiotracer distributed spacially over three dimensions. This process, using a detection device with an appreciably plane detection surface and at least one collimation orifice provided in a partition between the detection surface and the object, enables tomographic sections to be obtained with an excellent three-dimensional resolution of the images achieved. It is employed to advantage in an installation that includes a detection device or gamma camera on an appreciably plane surface, a device having a series of collimation apertures which may be used in succession, these holes being appreciably distributed over a common plane parallel to the detection surface, and a holder for the object. This holder can be moved in appreciably parallel translation to the common plane. The aim of this invention is, inter alia, to meet two requirements: localization in space and obtaining good contrasts. This aim is achieved by the fact that at least one tomographic image is obtained from a series of intermediate images of the object [fr

  19. Do Sex, Sex-Role Orientation, and Exposure to Gender-Congruent Therapy Models Influence Receptivity to Psychotherapy?

    Science.gov (United States)

    Park, Heather L.; Hatchett, Gregory T.

    2006-01-01

    This study had two objectives. The first objective was to evaluate how well sex and sex-role orientation predicted receptivity to psychotherapy. The second objective was to evaluate whether exposure to gender-congruent therapy videos influenced participants' receptivity to psychotherapy. Participants were randomly assigned to three conditions: (1)…

  20. Eugen Bleuler 150: Bleuler's reception of Freud.

    Science.gov (United States)

    Dalzell, Thomas G

    2007-12-01

    On the 150th anniversary of Eugen Bleuler's birth, this article examines his reception of Sigmund Freud and his use of Freudian theory to understand the symptoms of schizophrenia. In addition, in contrast to earlier interpretations of Bleuler's relationship with Freud in terms of an eventual personal and theoretical incompatibility, the article demonstrates that, although Bleuler did distance himself from the psychoanalytic movement, he remained consistent in his views on Freud's theories.

  1. Conceptual scoring of receptive and expressive vocabulary measures in simultaneous and sequential bilingual children.

    Science.gov (United States)

    Gross, Megan; Buac, Milijana; Kaushanskaya, Margarita

    2014-11-01

    The authors examined the effects of conceptual scoring on the performance of simultaneous and sequential bilinguals on standardized receptive and expressive vocabulary measures in English and Spanish. Participants included 40 English-speaking monolingual children, 39 simultaneous Spanish-English bilingual children, and 19 sequential bilingual children, ages 5-7. The children completed standardized receptive and expressive vocabulary measures in English and also in Spanish for those who were bilingual. After the standardized administration, bilingual children were given the opportunity to respond to missed items in their other language to obtain a conceptual score. Controlling for group differences in socioeconomic status (SES), both simultaneous and sequential bilingual children scored significantly below monolingual children on single-language measures of English receptive and expressive vocabulary. Conceptual scoring removed the significant difference between monolingual and simultaneous bilingual children in the receptive modality but not in the expressive modality; differences remained between monolingual and sequential bilingual children in both modalities. However, in both bilingual groups, conceptual scoring increased the proportion of children with vocabulary scores within the average range. Conceptual scoring does not fully ameliorate the bias inherent in single-language standardized vocabulary measures for bilingual children, but the procedures employed here may assist in ruling out vocabulary deficits, particularly in typically developing simultaneous bilingual children.

  2. Attention directed by expectations enhances receptive fields in cortical area MT.

    Science.gov (United States)

    Ghose, Geoffrey M; Bearl, David W

    2010-02-22

    Expectations, especially those formed on the basis of extensive training, can substantially enhance visual performance. However, it is not clear that the physiological mechanisms underlying this enhancement are identical to those examined by experiments in which attention is directed by explicit instructions rather than strong expectations. To study the changes in visual representations associated with strong expectations, we trained animals to detect a brief motion pulse that was embedded in noise. Because the nature of the pulse and the statistics of its appearance were well known to the animals, they formed strong expectations which determined their behavioral performance. We used white-noise methods to infer the receptive field structure of single neurons in area MT while they were performing this task. Incorporating non-linearities, we compared receptive fields during periods of time when the animals were expecting the motion pulse with periods of time when they were not. We found receptive field changes consistent with an increased reliability in signaling pulse occurrence. Moreover, these changes were not consistent with a simple gain modulation. The results suggest that strong expectations can create very specific changes in the visual representations at a cellular level to enhance performance. Copyright 2009 Elsevier Ltd. All rights reserved.

  3. Single-Shot, Volumetrically Illuminated, Three-Dimensional, Tomographic Laser-Induced-Fluorescence Imaging in a Gaseous Free Jet

    Science.gov (United States)

    2016-04-28

    Single-shot, volumetrically illuminated, three- dimensional, tomographic laser-induced- fluorescence imaging in a gaseous free jet Benjamin R. Halls...acquisition; (110.6955) Tomographic imaging ; (110.6960) Tomography; (280.2490) Flow diagnostics; (300.2530) Fluorescence , laser-induced...84 (1983). 2. I. van Cruyningen, A. Lozano, and R. K. Hanson, “Quantitative imaging of concentration by planar laser-induced fluorescence ,” Exp

  4. The reception of Roman law in the Romano-Germanic legal family rights: the case of French law

    OpenAIRE

    André Olavo Leite

    2017-01-01

    The Romano-Germanic family of legal systems, also known as the family of civil law, comprehends the group of legal systems that traditionally trace their roots up to the Roman law and the Justinian codifications, and that identify themselves as heirs of several of its characteristics. This paper analyses the example of French law, in order to draw on the permanence of Roman law in the contemporary legal systems of the Romano-Germanic family of rights and to show that its reception in those le...

  5. Ratios between effective doses for tomographic and mathematician models due to internal exposure of photons

    International Nuclear Information System (INIS)

    Lima, F.R.A.; Kramer, R.; Khoury, H.J.; Santos, A.M.; Loureiro, E.C.M.

    2005-01-01

    The development of new and sophisticated Monte Carlo codes and tomographic human phantoms or voxels motivated the International Commission on Radiological Protection (ICRP) to revise the traditional models of exposure, which have been used to calculate effective dose coefficients for organs and tissues based on mathematician phantoms known as MIRD5. This paper shows the results of calculations using tomographic phantoms MAX (Male Adult voXel) and FAX (Female Adult voXel), recently developed by the authors as well as with the phantoms ADAM and EVA, of specific genres, type MIRD5, coupled to the EGS4 Monte Carlo and MCNP4C codes, for internal exposure with photons of energies between 10 keV and 4 MeV to several organs sources. Effective Doses for both models, tomographic and mathematician, will be compared separately as a function of the Monte Carlo code replacement, of compositions of human tissues and the anatomy reproduced through tomographs. The results indicate that for photon internal exposure, the use of models of exposure based in voxel, increases the values of effective doses up to 70% for some organs sources considered in this study, when compared with the corresponding results obtained with phantoms of MIRD-5 type

  6. Quantum-tomographic cryptography with a semiconductor single-photon source

    International Nuclear Information System (INIS)

    Kaszlikowski, D.; Yang, L.J.; Yong, L.S.; Willeboordse, F.H.; Kwek, L.C.

    2005-01-01

    We analyze the security of so-called quantum-tomographic cryptography with the source producing entangled photons via an experimental scheme proposed by Fattal et al. [Phys. Rev. Lett. 92, 37903 (2004)]. We determine the range of the experimental parameters for which the protocol is secure against the most general incoherent attacks

  7. The Judaeo-Karaite Reception of the Hebrew Bible

    DEFF Research Database (Denmark)

    Sabih, Joshua

    DESCRIPTION: The Karaites emerged as a school of thought within Middle Eastern Judaism in the 8th century. The Karaites were a “reading community” whose intellectual activity and daily lives were based around the divine scriptures. Over time Karaism became one of the two main competing schools of...... between the Rabbinate and the Karaite reception and interpretation of the Hebrew Bible....

  8. Intervention for Mixed Receptive-Expressive Language Impairment: A Review

    Science.gov (United States)

    Boyle, James; McCartney, Elspeth; O'Hare, Anne; Law, James

    2010-01-01

    Studies indicate that language impairment that cannot be accounted for by factors such as below-average non-verbal ability, hearing impairment, behaviour or emotional problems, or neurological impairments affects some 6% of school-age children. Language impairment with a receptive language component is more resistant to intervention than specific…

  9. Semi-quantitative analysis of endometrial receptivity marker mRNA ...

    African Journals Online (AJOL)

    In fertile women, expression of molecular marker of endometrial receptivity, HOXA11, leukemia inhibitory factor (LIF) and basic transcriptional element binding protein 1 (BTEB1), rises during the luteal phase with the peak occurring during the implantation window. We evaluated the transcript levels of HOXA-11, LIF and ...

  10. Rethinking clinical language mapping approaches: discordant receptive and expressive hemispheric language dominance in epilepsy surgery candidates.

    Science.gov (United States)

    Gage, Nicole M; Eliashiv, Dawn S; Isenberg, Anna L; Fillmore, Paul T; Kurelowech, Lacey; Quint, Patti J; Chung, Jeffrey M; Otis, Shirley M

    2011-06-01

    Neuroimaging studies have shed light on cortical language organization, with findings implicating the left and right temporal lobes in speech processing converging to a left-dominant pattern. Findings highlight the fact that the state of theoretical language knowledge is ahead of current clinical language mapping methods, motivating a rethinking of these approaches. The authors used magnetoencephalography and multiple tasks in seven candidates for resective epilepsy surgery to investigate language organization. The authors scanned 12 control subjects to investigate the time course of bilateral receptive speech processes. Laterality indices were calculated for left and right hemisphere late fields ∼150 to 400 milliseconds. The authors report that (1) in healthy adults, speech processes activated superior temporal regions bilaterally converging to a left-dominant pattern, (2) in four of six patients, this was reversed, with bilateral processing converging to a right-dominant pattern, and (3) in three of four of these patients, receptive and expressive language processes were laterally discordant. Results provide evidence that receptive and expressive language may have divergent hemispheric dominance. Right-sided receptive language dominance in epilepsy patients emphasizes the need to assess both receptive and expressive language. Findings indicate that it is critical to use multiple tasks tapping separable aspects of language function to provide sensitive and specific estimates of language localization in surgical patients.

  11. Computed Tomographic Perfusion Improves Diagnostic Power of Coronary Computed Tomographic Angiography in Women

    DEFF Research Database (Denmark)

    Penagaluri, Ashritha; Higgins, Angela Y.; Vavere, Andrea L

    2016-01-01

    laboratories. Prevalence of flow-limiting CAD defined by invasive coronary angiography equal to 50% or greater with an associated single-photon emission computed tomography myocardial perfusion imaging defect was 45% (114/252) and 23% (30/129) in males and females, respectively. Patient-based diagnostic......Background-Coronary computed tomographic angiography (CTA) and myocardial perfusion imaging (CTP) is a validated approach for detection and exclusion of flow-limiting coronary artery disease (CAD), but little data are available on gender-specific performance of these modalities. In this study, we...... aimed to evaluate the diagnostic accuracy of combined coronary CTA and CTP in detecting flow-limiting CAD in women compared with men.  Methods and Results-Three hundred and eighty-one patients who underwent both CTA-CTP and single-photon emission computed tomography myocardial perfusion imaging...

  12. Investigating Arabic Academic Vocabulary Knowledge Among Middle School Pupils: Receptive Versus Productive Knowledge.

    Science.gov (United States)

    Makhoul, Baha

    2017-08-01

    The current study attempted to investigate the development of Arabic academic vocabulary knowledge among middle-school Arabic native speakers, taking into account the socioeconomic status of the Arab population in Israel. For this purpose, Arabic academic word list was developed, mapping the required academic words that are needed for adequate coping with informational texts as appearing in the different content areas text-books. Six-hundred Arabic speaking middle school pupils from the different areas in Israel, representing the different Arab subgroups: general Arab community, Druze and Bedouins, have participated in the current study. Two academic vocabulary tests, including receptive and productive academic vocabulary evaluation tests, were administrated to the students across the different age groups (7th, 8th and 9th). The results pointed to no significant difference between 7th and 9th grade in academic vocabulary knowledge. In contrast, significant difference was encountered between the different Arab sub-groups where the lowest scores were noted among the Bedouin sub-group, characterized by the lowest SES. When comparing receptive and productive academic vocabulary knowledge between 7th and 9th grade, the results pointed to improvement in receptive academic knowledge towards the end of middle school but not on the productive knowledge level. In addition, within participants' comparison indicated a gap between the pupils' receptive and productive vocabulary. The results are discussed in relation to the existing scientific literature and to its implication of both research and practice in the domain of Arabic literacy development.

  13. The inverse problems of reconstruction in the X-rays, gamma or positron tomographic imaging systems

    International Nuclear Information System (INIS)

    Grangeat, P.

    1999-01-01

    The revolution in imagery, brought by the tomographic technic in the years 70, allows the computation of local values cartography for the attenuation or the emission activity. The reconstruction techniques thus allow the connection from integral measurements to characteristic information distribution by inversion of the measurement equations. They are a main application of the solution technic for inverse problems. In a first part the author recalls the physical principles for measures in X-rays, gamma and positron imaging. Then he presents the various problems with their associated inversion techniques. The third part is devoted to the activity sector and examples, to conclude in the last part with the forecast. (A.L.B.)

  14. Computed tomographic findings in manifesting carriers of Duchenne muscular dystrophy

    NARCIS (Netherlands)

    de Visser, M.; Verbeeten, B.

    1985-01-01

    Clinical and computed tomographic (CT) findings in 3 manifesting carriers of Duchenne muscular dystrophy are reported. CT proved to be an important adjunct to the clinical examination: in all our 3 cases a decrease in density was found in various non-paretic muscles

  15. Nonredundant sparse feature extraction using autoencoders with receptive fields clustering.

    Science.gov (United States)

    Ayinde, Babajide O; Zurada, Jacek M

    2017-09-01

    This paper proposes new techniques for data representation in the context of deep learning using agglomerative clustering. Existing autoencoder-based data representation techniques tend to produce a number of encoding and decoding receptive fields of layered autoencoders that are duplicative, thereby leading to extraction of similar features, thus resulting in filtering redundancy. We propose a way to address this problem and show that such redundancy can be eliminated. This yields smaller networks and produces unique receptive fields that extract distinct features. It is also shown that autoencoders with nonnegativity constraints on weights are capable of extracting fewer redundant features than conventional sparse autoencoders. The concept is illustrated using conventional sparse autoencoder and nonnegativity-constrained autoencoders with MNIST digits recognition, NORB normalized-uniform object data and Yale face dataset. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Computer tomographic detection of an intraspinal arachnoidal cyst

    International Nuclear Information System (INIS)

    Kuckein, D.; Walter, K.; Paal, G.; Staedtisches Krankenhaus Harlaching, Muenchen

    1981-01-01

    A 46 year old female patient who after 3-4 weeks of influenza suffered from strong headaches, vomiting and rotatory vertigo was subjected to a myelograph and then to a computerized tomographic investigation due to suspect cerebrospinal fluid. The computerized tomography is better than the myelography in diagnosing intraspinal arachnoidal cysts, however this should be preceded by most accurate possible segment location. (MG) [de

  17. Heidelberg Retina Tomograph for the Detection of Glaucoma

    Directory of Open Access Journals (Sweden)

    Barbara Cvenkel

    2012-06-01

    Full Text Available Heidelberg Retina Tomograph (HRT is a confocal scanning laser ophthalmoscope which acquires and analyzes 3-dimensional images of the optic nerve head. The latest instrument HRT3 includes software with larger ethinic-specific normative database. This review summarizes relevant published literature on HRT in diagnosing glaucoma, detecting glaucoma progression, the diagnostic accuracy of HRT among other imaging devices and its role in clinical practice.

  18. THE RECEPTION OF GALATIANS 2:20 IN THE PATRISTIC PERIOD ...

    African Journals Online (AJOL)

    This article explores the reception of Galatians 2:20 in the Patristic period, and ... theological framework in which later generations placed the communities wherein ... quality of reality – and in Christ that is as perfect as eternal life can ever be.

  19. The Use of Chest Computed Tomographic Angiography in Blunt Trauma Pediatric Population.

    Science.gov (United States)

    Hasadia, Rabea; DuBose, Joseph; Peleg, Kobi; Stephenson, Jacob; Givon, Adi; Kessel, Boris

    2018-02-05

    Blunt chest trauma in children is common. Although rare, associated major thoracic vascular injuries (TVIs) are lethal potential sequelae of these mechanisms. The preferred study for definitive diagnosis of TVI in stable patients is computed tomographic angiography imaging of the chest. This imaging modality is, however, associated with high doses of ionizing radiation that represent significant carcinogenic risk for pediatric patients. The aim of the present investigation was to define the incidence of TVI among blunt pediatric trauma patients in an effort to better elucidate the usefulness of computed tomographic angiography use in this population. A retrospective cohort study was conducted including all blunt pediatric (age blunt trauma victims, 119,821patients were younger than 14 years. Twelve (0.0001%, 12/119821) of these children were diagnosed with TVI. The most common mechanism in this group was pedestrian hit by a car. Mortality was 41.7% (5/12). Thoracic vascular injury is exceptionally rare among pediatric blunt trauma victims but does contribute to the high morbidity and mortality seen with blunt chest trauma. Computed tomographic angiography, with its associated radiation exposure risk, should not be used as a standard tool after trauma in injured children. Clinical protocols are needed in this population to minimize radiation risk while allowing prompt identification of life-threatening injuries.

  20. Hypothesis: Co-transfer of genuine embryos and implantation-promoting compounds via artificial containers improve endometrium receptivity.

    Science.gov (United States)

    Celik, Onder; Acet, Mustafa; Celik, Sudenaz; Sahin, Levent; Koc, Onder; Celik, Nilufer

    2017-06-01

    As with other organs endometrial functions are altered with the advancing age. Age related decrease in reproductive functions leads to decline in the number of oocytes retrieved and the synthesis of endometrial receptivity molecules. Despite the significant improvement in assisted reproductive technologies we do not have so many options to enhance endometrial receptivity. Due to lack of drugs having endometrium receptivity enhancement properties, oocyte donation seems to be the only solution for women with implantation failure. The euploid oocytes come from young and healthy donors may overcome age associated endometrial receptivity defect. Nevertheless, many reasons restrict us from using oocyte donation in women with implantation failure. We, therefore, hypothesized that by mimicking a young blastocyst's effect on endometrium, the transfer of genuine embryos and implantation-promoting compounds together might be the new treatment option for infertile women with recurrent implantation failure. Artificial beads, MI or GV oocytes, and empty zona can be used as a container for intrauterine replacement of implantation-promoting compounds. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Tomographic retrieval of cloud liquid water fields from a single scanning microwave radiometer aboard a moving platform – Part 1: Field trial results from the Wakasa Bay experiment

    Directory of Open Access Journals (Sweden)

    D. Huang

    2010-07-01

    Full Text Available Tomographic methods offer great potential for retrieving three-dimensional spatial distributions of cloud liquid water from radiometric observations by passive microwave sensors. Fixed tomographic systems require multiple radiometers, while mobile systems can use just a single radiometer. Part 1 (this paper examines the results from a limited cloud tomography trial with a single-radiometer airborne system carried out as part of the 2003 AMSR-E validation campaign over Wakasa Bay of the Sea of Japan. During this trial, the Polarimetric Scanning Radiometer (PSR and Microwave Imaging Radiometer (MIR aboard the NASA P-3 research aircraft provided a useful dataset for testing the cloud tomography method over a system of low-level clouds. We do tomographic retrievals with a constrained inversion algorithm using three configurations: PSR, MIR, and combined PSR and MIR data. The liquid water paths from the PSR retrieval are consistent with those from the MIR retrieval. The retrieved cloud field based on the combined data appears to be physically plausible and consistent with the cloud image obtained by a cloud radar. We find that some vertically-uniform clouds appear at high altitudes in the retrieved field where the radar shows clear sky. This is likely due to the sub-optimal data collection strategy. This sets the stage for Part 2 of this study that aims to define optimal data collection strategies using observation system simulation experiments.

  2. Concern About Hunger May Increase Receptivity to GMOs.

    Science.gov (United States)

    Carter, B Elijah; Conn, Caitlin C; Wiles, Jason R

    2016-07-01

    Due to a phenomenon known as the 'backfire effect', intuition-based opinions can be inadvertently strengthened by evidence-based counterarguments. Students' views on genetically modified organisms (GMOs) may be subject to this effect. We explored the impact of an empathetically accessible topic, world hunger, on receptivity to GMO technology as an alternative to direct evidence-based approaches. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Computed Tomographic Morphometry of the Internal Anatomy of Mandibular Second Primary Molars.

    Science.gov (United States)

    Kurthukoti, Ameet J; Sharma, Pranjal; Swamy, Dinesh Francis; Shashidara, R; Swamy, Elaine Barretto

    2015-01-01

    Need for the study: The most important procedure for a successful endodontic treatment is the cleaning and shaping of the canal system. Understanding the internal anatomy of teeth provides valuable information to the clinician that would help him achieve higher clinical success during endodontic therapy. To evaluate by computed tomography-the internal anatomy of mandibular second primary molars with respect to the number of canals, cross-sectional shape of canals, cross-sectional area of canals and the root dentin thickness. A total of 31 mandibular second primary molars were subjected to computed-tomographic evaluation in the transverse plane, after mounting them in a prefabricated template. The images, thus, obtained were analyzed using De-winter Bio-wizard® software. All the samples demonstrated two canals in the mesial root, while majority of the samples (65.48%) demonstrated two canals in the distal root. The cross-sectional images of the mesial canals demonstrated a round shape, while the distal canals demonstrated an irregular shape. The root dentin thickness was highly reduced on the distal aspect of mesial and mesial aspect of distal canals. The mandibular second primary molars demonstrated wide variation and complexities in their internal anatomy. A thorough understanding of the complexity of the root canal system is essential for understanding the principles and problems of shaping and cleaning, determining the apical limits and dimensions of canal preparations, and for performing successful endodontic procedures. How to cite this article: Kurthukoti AJ, Sharma P, Swamy DF, Shashidara R, Swamy EB. Computed Tomographic Morphometry of the Internal Anatomy of Mandibular Second Primary Molars. Int J Clin Pediatr Dent 2015;8(3):202-207.

  4. Adolescent Weight Status and Receptivity to Food TV Advertisements

    Science.gov (United States)

    Adachi-Mejia, Anna M.; Sutherland, Lisa A.; Longacre, Meghan R.; Beach, Michael L.; Titus-Ernstoff, Linda; Gibson, Jennifer J.; Dalton, Madeline A.

    2011-01-01

    Objective: This study examined the relationship between adolescent weight status and food advertisement receptivity. Design: Survey-based evaluation with data collected at baseline (initial and at 2 months), and at follow-up (11 months). Setting: New Hampshire and Vermont. Participants: Students (n = 2,281) aged 10-13 in 2002-2005. Main Outcome…

  5. KIRA1 and ORESARA1 terminate flower receptivity by promoting cell death in the stigma of Arabidopsis.

    Science.gov (United States)

    Gao, Zhen; Daneva, Anna; Salanenka, Yuliya; Van Durme, Matthias; Huysmans, Marlies; Lin, Zongcheng; De Winter, Freya; Vanneste, Steffen; Karimi, Mansour; Van de Velde, Jan; Vandepoele, Klaas; Van de Walle, Davy; Dewettinck, Koen; Lambrecht, Bart N; Nowack, Moritz K

    2018-05-28

    Flowers have a species-specific functional life span that determines the time window in which pollination, fertilization and seed set can occur. The stigma tissue plays a key role in flower receptivity by intercepting pollen and initiating pollen tube growth toward the ovary. In this article, we show that a developmentally controlled cell death programme terminates the functional life span of stigma cells in Arabidopsis. We identified the leaf senescence regulator ORESARA1 (also known as ANAC092) and the previously uncharacterized KIRA1 (also known as ANAC074) as partially redundant transcription factors that modulate stigma longevity by controlling the expression of programmed cell death-associated genes. KIRA1 expression is sufficient to induce cell death and terminate floral receptivity, whereas lack of both KIRA1 and ORESARA1 substantially increases stigma life span. Surprisingly, the extension of stigma longevity is accompanied by only a moderate extension of flower receptivity, suggesting that additional processes participate in the control of the flower's receptive life span.

  6. Early language processing efficiency predicts later receptive vocabulary outcomes in children born preterm.

    Science.gov (United States)

    Marchman, Virginia A; Adams, Katherine A; Loi, Elizabeth C; Fernald, Anne; Feldman, Heidi M

    2016-01-01

    As rates of prematurity continue to rise, identifying which preterm children are at increased risk for learning disabilities is a public health imperative. Identifying continuities between early and later skills in this vulnerable population can also illuminate fundamental neuropsychological processes that support learning in all children. At 18 months adjusted age, we used socioeconomic status (SES), medical variables, parent-reported vocabulary, scores on the Bayley Scales of Infant and Toddler Development (third edition) language composite, and children's lexical processing speed in the looking-while-listening (LWL) task as predictor variables in a sample of 30 preterm children. Receptive vocabulary as measured by the Peabody Picture Vocabulary Test (fourth edition) at 36 months was the outcome. Receptive vocabulary was correlated with SES, but uncorrelated with degree of prematurity or a composite of medical risk. Importantly, lexical processing speed was the strongest predictor of receptive vocabulary (r = -.81), accounting for 30% unique variance. Individual differences in lexical processing efficiency may be able to serve as a marker for information processing skills that are critical for language learning.

  7. Influence of Heat Treatment of Nickel-Titanium Rotary Endodontic Instruments on Apical Preparation: A Micro-Computed Tomographic Study.

    Science.gov (United States)

    de Almeida, Bernardo Corrêa; Ormiga, Fabíola; de Araújo, Marcos César Pimenta; Lopes, Ricardo Tadeu; Lima, Inayá Corrêa Barbosa; dos Santos, Bernardo Camargo; Gusman, Heloisa

    2015-12-01

    The aim of this study was to make a 3-dimensional comparison of the canal transportation and changes in apical geometry using micro-computed tomographic imaging after canal preparation with K3 (SybronEndo, Orange, CA) and K3XF (SybronEndo) file systems. Twenty-eight mandibular molars were randomly divided into 2 groups according to the rotary system used in instrumentation: K3 or K3XF. The specimens were scanned by micro-computed tomographic imaging before and after instrumentation. Images before and after instrumentation from each group were compared with regard to canal volume, surface area, and structure model index (SMI) (paired t test, P instrumentation, the canals from each group were compared regarding the changes in volume, surface area, SMI, and canal transportation in the last 4 apical mm (t test, P Instrumentation with the 2 rotary systems significantly changed the canal volume, surface area, and SMI (P instrument types concerning these parameters (P > .05). There were no significant differences between the 2 groups with regard to canal transportation in the last 4 apical mm (P > .05). Both rotary systems showed adequate canal preparations with reduced values of canal transportation. Heat treatment did not influence changes in root canal geometry in the apical region. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Transition Prediction in Hypersonic Boundary Layers Using Receptivity and Freestream Spectra

    Science.gov (United States)

    Balakumar, P.; Chou, Amanda

    2016-01-01

    Boundary-layer transition in hypersonic flows over a straight cone can be predicted using measured freestream spectra, receptivity, and threshold values for the wall pressure fluctuations at the transition onset points. Simulations are performed for hypersonic boundary-layer flows over a 7-degree half-angle straight cone with varying bluntness at a freestream Mach number of 10. The steady and the unsteady flow fields are obtained by solving the two-dimensional Navier-Stokes equations in axisymmetric coordinates using a 5th-order accurate weighted essentially non-oscillatory (WENO) scheme for space discretization and using a third-order total-variation-diminishing (TVD) Runge-Kutta scheme for time integration. The calculated N-factors at the transition onset location increase gradually with increasing unit Reynolds numbers for flow over a sharp cone and remain almost the same for flow over a blunt cone. The receptivity coefficient increases slightly with increasing unit Reynolds numbers. They are on the order of 4 for a sharp cone and are on the order of 1 for a blunt cone. The location of transition onset predicted from the simulation including the freestream spectrum, receptivity, and the linear and the weakly nonlinear evolutions yields a solution close to the measured onset location for the sharp cone. The simulations over-predict transition onset by about twenty percent for the blunt cone.

  9. The development of a compact positron tomograph for prostate imaging

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Jennifer S.; Qi, Jinyi; Derenzo, Stephen E.; Moses, William W.; Huesman, Ronald H.; Budinger, Thomas F.

    2002-12-17

    We give design details and expected image results of a compact positron tomograph designed for prostate imaging that centers a patient between a pair of external curved detector banks (ellipse: 45 cm minor, 70 cm major axis). The bottom bank is fixed below the patient bed, and the top bank moves upward for patient access and downward for maximum sensitivity. Each bank is composed of two rows (axially) of 20 CTI PET Systems HR+ block detectors, forming two arcs that can be tilted to minimize attenuation. Compared to a conventional PET system, our camera uses about one-quarter the number of detectors and has almost two times higher solid angle coverage for a central point source, because the detectors are close to the patient. The detectors are read out by modified CTI HRRT data acquisition electronics. The individual detectors are angled in the plane to point towards the prostate to minimize reso

  10. Multinomial Bayesian learning for modeling classical and nonclassical receptive field properties.

    Science.gov (United States)

    Hosoya, Haruo

    2012-08-01

    We study the interplay of Bayesian inference and natural image learning in a hierarchical vision system, in relation to the response properties of early visual cortex. We particularly focus on a Bayesian network with multinomial variables that can represent discrete feature spaces similar to hypercolumns combining minicolumns, enforce sparsity of activation to learn efficient representations, and explain divisive normalization. We demonstrate that maximal-likelihood learning using sampling-based Bayesian inference gives rise to classical receptive field properties similar to V1 simple cells and V2 cells, while inference performed on the trained network yields nonclassical context-dependent response properties such as cross-orientation suppression and filling in. Comparison with known physiological properties reveals some qualitative and quantitative similarities.

  11. Design and evaluation of HEADTOME-IV, a whole-body positron emission tomograph

    International Nuclear Information System (INIS)

    Iida, H.; Miura, S.; Kanno, I.; Murakami, M.; Takahashi, K.; Uemura, K.

    1989-01-01

    A whole body positron emission tomograph HEADTOME-IV has been developed, and its physical performances were investigated. The in-plane spatial resolution of 4.5 mm was realized with stationary-sampling at the center of the field-of-view. The axial slice thickness was 9.5 and 9.0-mm for direct and cross planes, respectively. By moving the gantry framework axially, transaxial images of 14 or 21 slices are obtained quasi-simultaneously. The realtime-operation large-scale cache memory system was effective to realize realtime corrections for deadtime and radionuclide decay, and realtime weighted integration for the purpose of a rapid calculation of rate-constant images

  12. The auditory anatomy of the minke whale (Balaenoptera acutorostrata): a potential fatty sound reception pathway in a baleen whale.

    Science.gov (United States)

    Yamato, Maya; Ketten, Darlene R; Arruda, Julie; Cramer, Scott; Moore, Kathleen

    2012-06-01

    Cetaceans possess highly derived auditory systems adapted for underwater hearing. Odontoceti (toothed whales) are thought to receive sound through specialized fat bodies that contact the tympanoperiotic complex, the bones housing the middle and inner ears. However, sound reception pathways remain unknown in Mysticeti (baleen whales), which have very different cranial anatomies compared to odontocetes. Here, we report a potential fatty sound reception pathway in the minke whale (Balaenoptera acutorostrata), a mysticete of the balaenopterid family. The cephalic anatomy of seven minke whales was investigated using computerized tomography and magnetic resonance imaging, verified through dissections. Findings include a large, well-formed fat body lateral, dorsal, and posterior to the mandibular ramus and lateral to the tympanoperiotic complex. This fat body inserts into the tympanoperiotic complex at the lateral aperture between the tympanic and periotic bones and is in contact with the ossicles. There is also a second, smaller body of fat found within the tympanic bone, which contacts the ossicles as well. This is the first analysis of these fatty tissues' association with the auditory structures in a mysticete, providing anatomical evidence that fatty sound reception pathways may not be a unique feature of odontocete cetaceans. Copyright © 2012 Wiley Periodicals, Inc.

  13. Exceptionally preserved Cambrian trilobite digestive system revealed in 3D by synchrotron-radiation X-ray tomographic microscopy.

    Directory of Open Access Journals (Sweden)

    Mats E Eriksson

    Full Text Available The Cambrian 'Orsten' fauna comprises exceptionally preserved and phosphatised microscopic arthropods. The external morphology of these fossils is well known, but their internal soft-tissue anatomy has remained virtually unknown. Here, we report the first non-biomineralised tissues from a juvenile polymerid trilobite, represented by digestive structures, glands, and connective strands harboured in a hypostome from the Swedish 'Orsten' fauna. Synchrotron-radiation X-ray tomographic microscopy enabled three-dimensional internal recordings at sub-micrometre resolution. The specimen provides the first unambiguous evidence for a J-shaped anterior gut and the presence of a crop with a constricted alimentary tract in the Trilobita. Moreover, the gut is Y-shaped in cross section, probably due to a collapsed lumen of that shape, another feature which has not previously been observed in trilobites. The combination of anatomical features suggests that the trilobite hypostome is functionally analogous to the labrum of euarthropods and that it was a sophisticated element closely integrated with the digestive system. This study also briefly addresses the preservational bias of the 'Orsten' fauna, particularly the near-absence of polymerid trilobites, and the taphonomy of the soft-tissue-harbouring hypostome.

  14. Receptive Learning Styles Of Introverts, Ambiverts And Extroverts In ...

    African Journals Online (AJOL)

    Learning to relate with people in their own style is important in helping to understand why they react the way they do. The purpose of this study therefore was to determine the differences in the receptive learning styles of introverts, ambiverts and extroverts in Senior High Schools (SHS) in the Sekondi-Takoradi Metropolis, ...

  15. The routes to be followed into Alberto Caeiros’s poetry: a reception aesthetics approach

    Directory of Open Access Journals (Sweden)

    Fabrício César Aguiar

    2011-10-01

    Full Text Available The aim of this article is to study the 8th poem Num meio dia de fim de primavera written by Alberto Caeiro. The analysis proposed will be based on some of the Reception Aesthetics concepts mainly focusing on enriching the sensory aspects of the text, especially the visual one. For that purpose, the poetic devices used in the construction of the text as well as its reception by the readers will be highlighted. The analysis will be based on the concepts theorized by Wolfgang Iser. Such concepts are: a the interaction between text and reader and the position of the latter at the time of the former reception; b the blank places; c the negation and negativity structures; and d it will also consider the approach to reading as an act in which the reader is responsible for achieving the meaning for the text and for creating an “aesthetic pleasure” through it. This last concept is grounded in Hans Robert Jauss theory.

  16. TomoPy: a framework for the analysis of synchrotron tomographic data

    International Nuclear Information System (INIS)

    Gürsoy, Doǧa; De Carlo, Francesco; Xiao, Xianghui; Jacobsen, Chris

    2014-01-01

    A collaborative framework for the analysis of synchrotron tomographic data which has the potential to unify the effort of different facilities and beamlines performing similar tasks is described. The proposed Python-based framework is open-source, platform- and data-format-independent, has multiprocessing capability and supports functional programming that many researchers prefer. Analysis of tomographic datasets at synchrotron light sources (including X-ray transmission tomography, X-ray fluorescence microscopy and X-ray diffraction tomography) is becoming progressively more challenging due to the increasing data acquisition rates that new technologies in X-ray sources and detectors enable. The next generation of synchrotron facilities that are currently under design or construction throughout the world will provide diffraction-limited X-ray sources and are expected to boost the current data rates by several orders of magnitude, stressing the need for the development and integration of efficient analysis tools. Here an attempt to provide a collaborative framework for the analysis of synchrotron tomographic data that has the potential to unify the effort of different facilities and beamlines performing similar tasks is described in detail. The proposed Python-based framework is open-source, platform- and data-format-independent, has multiprocessing capability and supports procedural programming that many researchers prefer. This collaborative platform could affect all major synchrotron facilities where new effort is now dedicated to developing new tools that can be deployed at the facility for real-time processing, as well as distributed to users for off-site data processing

  17. TomoPy: a framework for the analysis of synchrotron tomographic data

    Energy Technology Data Exchange (ETDEWEB)

    Gürsoy, Doǧa, E-mail: dgursoy@aps.anl.gov; De Carlo, Francesco; Xiao, Xianghui; Jacobsen, Chris [Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439-4837 (United States)

    2014-08-01

    A collaborative framework for the analysis of synchrotron tomographic data which has the potential to unify the effort of different facilities and beamlines performing similar tasks is described. The proposed Python-based framework is open-source, platform- and data-format-independent, has multiprocessing capability and supports functional programming that many researchers prefer. Analysis of tomographic datasets at synchrotron light sources (including X-ray transmission tomography, X-ray fluorescence microscopy and X-ray diffraction tomography) is becoming progressively more challenging due to the increasing data acquisition rates that new technologies in X-ray sources and detectors enable. The next generation of synchrotron facilities that are currently under design or construction throughout the world will provide diffraction-limited X-ray sources and are expected to boost the current data rates by several orders of magnitude, stressing the need for the development and integration of efficient analysis tools. Here an attempt to provide a collaborative framework for the analysis of synchrotron tomographic data that has the potential to unify the effort of different facilities and beamlines performing similar tasks is described in detail. The proposed Python-based framework is open-source, platform- and data-format-independent, has multiprocessing capability and supports procedural programming that many researchers prefer. This collaborative platform could affect all major synchrotron facilities where new effort is now dedicated to developing new tools that can be deployed at the facility for real-time processing, as well as distributed to users for off-site data processing.

  18. Callosal Influence on Visual Receptive Fields Has an Ocular, an Orientation-and Direction Bias

    Directory of Open Access Journals (Sweden)

    Sergio A. Conde-Ocazionez

    2018-04-01

    Full Text Available One leading hypothesis on the nature of visual callosal connections (CC is that they replicate features of intrahemispheric lateral connections. However, CC act also in the central part of the binocular visual field. In agreement, early experiments in cats indicated that they provide the ipsilateral eye part of binocular receptive fields (RFs at the vertical midline (Berlucchi and Rizzolatti, 1968, and play a key role in stereoscopic function. But until today callosal inputs to receptive fields activated by one or both eyes were never compared simultaneously, because callosal function has been often studied by cutting or lesioning either corpus callosum or optic chiasm not allowing such a comparison. To investigate the functional contribution of CC in the intact cat visual system we recorded both monocular and binocular neuronal spiking responses and receptive fields in the 17/18 transition zone during reversible deactivation of the contralateral hemisphere. Unexpectedly from many of the previous reports, we observe no change in ocular dominance during CC deactivation. Throughout the transition zone, a majority of RFs shrink, but several also increase in size. RFs are significantly more affected for ipsi- as opposed to contralateral stimulation, but changes are also observed with binocular stimulation. Noteworthy, RF shrinkages are tiny and not correlated to the profound decreases of monocular and binocular firing rates. They depend more on orientation and direction preference than on eccentricity or ocular dominance of the receiving neuron's RF. Our findings confirm that in binocularly viewing mammals, binocular RFs near the midline are constructed via the direct geniculo-cortical pathway. They also support the idea that input from the two eyes complement each other through CC: Rather than linking parts of RFs separated by the vertical meridian, CC convey a modulatory influence, reflecting the feature selectivity of lateral circuits, with a

  19. Discriminative learning of receptive fields from responses to non-Gaussian stimulus ensembles.

    Science.gov (United States)

    Meyer, Arne F; Diepenbrock, Jan-Philipp; Happel, Max F K; Ohl, Frank W; Anemüller, Jörn

    2014-01-01

    Analysis of sensory neurons' processing characteristics requires simultaneous measurement of presented stimuli and concurrent spike responses. The functional transformation from high-dimensional stimulus space to the binary space of spike and non-spike responses is commonly described with linear-nonlinear models, whose linear filter component describes the neuron's receptive field. From a machine learning perspective, this corresponds to the binary classification problem of discriminating spike-eliciting from non-spike-eliciting stimulus examples. The classification-based receptive field (CbRF) estimation method proposed here adapts a linear large-margin classifier to optimally predict experimental stimulus-response data and subsequently interprets learned classifier weights as the neuron's receptive field filter. Computational learning theory provides a theoretical framework for learning from data and guarantees optimality in the sense that the risk of erroneously assigning a spike-eliciting stimulus example to the non-spike class (and vice versa) is minimized. Efficacy of the CbRF method is validated with simulations and for auditory spectro-temporal receptive field (STRF) estimation from experimental recordings in the auditory midbrain of Mongolian gerbils. Acoustic stimulation is performed with frequency-modulated tone complexes that mimic properties of natural stimuli, specifically non-Gaussian amplitude distribution and higher-order correlations. Results demonstrate that the proposed approach successfully identifies correct underlying STRFs, even in cases where second-order methods based on the spike-triggered average (STA) do not. Applied to small data samples, the method is shown to converge on smaller amounts of experimental recordings and with lower estimation variance than the generalized linear model and recent information theoretic methods. Thus, CbRF estimation may prove useful for investigation of neuronal processes in response to natural stimuli and

  20. Discriminative learning of receptive fields from responses to non-Gaussian stimulus ensembles.

    Directory of Open Access Journals (Sweden)

    Arne F Meyer

    Full Text Available Analysis of sensory neurons' processing characteristics requires simultaneous measurement of presented stimuli and concurrent spike responses. The functional transformation from high-dimensional stimulus space to the binary space of spike and non-spike responses is commonly described with linear-nonlinear models, whose linear filter component describes the neuron's receptive field. From a machine learning perspective, this corresponds to the binary classification problem of discriminating spike-eliciting from non-spike-eliciting stimulus examples. The classification-based receptive field (CbRF estimation method proposed here adapts a linear large-margin classifier to optimally predict experimental stimulus-response data and subsequently interprets learned classifier weights as the neuron's receptive field filter. Computational learning theory provides a theoretical framework for learning from data and guarantees optimality in the sense that the risk of erroneously assigning a spike-eliciting stimulus example to the non-spike class (and vice versa is minimized. Efficacy of the CbRF method is validated with simulations and for auditory spectro-temporal receptive field (STRF estimation from experimental recordings in the auditory midbrain of Mongolian gerbils. Acoustic stimulation is performed with frequency-modulated tone complexes that mimic properties of natural stimuli, specifically non-Gaussian amplitude distribution and higher-order correlations. Results demonstrate that the proposed approach successfully identifies correct underlying STRFs, even in cases where second-order methods based on the spike-triggered average (STA do not. Applied to small data samples, the method is shown to converge on smaller amounts of experimental recordings and with lower estimation variance than the generalized linear model and recent information theoretic methods. Thus, CbRF estimation may prove useful for investigation of neuronal processes in response to

  1. THE INVESTIGATION OF PRODUCTIVE AND RECEPTIVE COMPETENCE IN V+N AND ADJ+N COLLOCATIONS AMONG INDONESIAN EFL LEARNERS

    Directory of Open Access Journals (Sweden)

    Saudin Saudin

    2017-05-01

    Full Text Available The important role of collocation in learners’ language proficiency has been acknowledged widely. In Systemic Functional Linguistics (SFL, collocation is known as one prominent member of the super-ordinate lexical cohesion, which contributes significantly to the textual coherence, together with grammatical cohesion and structural cohesion (Halliday & Hasan, 1985. Collocation is also viewed as the hallmark of truly advanced English learners since the higher the learners’ proficiency is, the more they tend to use collocation (Bazzaz & Samad, 2011; Hsu, 2007; Zhang, 1993. Further, knowledge of collocation is regarded as part of the native speakers’ communicative competence (Bazzaz & Samad, 2011; and lack of the knowledge is the most important sign of foreignness among foreign language learners (McArthur, 1992; McCarthy, 1990. Taking the importance of collocation into account, this study is aimed to shed light on Indonesian EFL learners’ levels of collocational competence. In the study, the collocational competence is restricted to v+n and adj+n of collocation but broken down into productive and receptive competence, about which little work has been done (Henriksen, 2013. For this purpose, 49 second-year students of an English department in a state polytechnic were chosen as the subjects. Two sets of tests (filling in the blanks and multiple-choice were administered to obtain the data of the subjects’ levels of productive and receptive competence and to gain information of which type was more problematic for the learners. The test instruments were designed by referring to Brashi’s (2006 test model, and Koya’s (2003. In the analysis of the data, interpretive-qualitative method was used primarily to obtain broad explanatory information. The data analysis showed that the scores of productive competence were lower than those of receptive competence in both v+n and adj+n collocation. The analysis also revealed that the scores of productive

  2. Receptive Language Skills in Slovak-Speaking Children With Intellectual Disability: Understanding Words, Sentences, and Stories.

    Science.gov (United States)

    Polišenská, Kamila; Kapalková, Svetlana; Novotková, Monika

    2018-06-05

    The study aims to describe receptive language skills in children with intellectual disability (ID) and to contribute to the debate on deviant versus delayed language development. This is the 1st study of receptive skills in children with ID who speak a Slavic language, providing insight into how language development is affected by disability and also language typology. Twenty-eight Slovak-speaking children participated in the study (14 children with ID and 14 typically developing [TD] children matched on nonverbal reasoning abilities). The children were assessed by receptive language tasks targeting words, sentences, and stories, and the groups were compared quantitatively and qualitatively. The groups showed similar language profiles, with a better understanding of words, followed by sentences, with the poorest comprehension for stories. Nouns were comprehended better than verbs; sentence constructions also showed a qualitatively similar picture, although some dissimilarities emerged. Verb comprehension was strongly related to sentence comprehension in both groups and related to story comprehension in the TD group only. The findings appear to support the view that receptive language skills follow the same developmental route in children with ID as seen in younger TD children, suggesting that language development is a robust process and does not seem to be differentially affected by ID even when delayed.

  3. Effects of serial and concurrent training on receptive identification tasks: A Systematic replication.

    Science.gov (United States)

    Wunderlich, Kara L; Vollmer, Timothy R

    2017-07-01

    The current study compared the use of serial and concurrent methods to train multiple exemplars when teaching receptive language skills, providing a systematic replication of Wunderlich, Vollmer, Donaldson, and Phillips (2014). Five preschoolers diagnosed with developmental delays or autism spectrum disorders were taught to receptively identify letters or letter sounds. Subjects learned the target stimuli slightly faster in concurrent training and a high degree of generalization was obtained following both methods of training, indicating that both the serial and concurrent methods of training are efficient and effective instructional procedures. © 2017 Society for the Experimental Analysis of Behavior.

  4. Tomographic Image Reconstruction Using Training Images with Matrix and Tensor Formulations

    DEFF Research Database (Denmark)

    Soltani, Sara

    the image resolution compared to a classical reconstruction method such as Filtered Back Projection (FBP). Some priors for the tomographic reconstruction take the form of cross-section images of similar objects, providing a set of the so-called training images, that hold the key to the structural......Reducing X-ray exposure while maintaining the image quality is a major challenge in computed tomography (CT); since the imperfect data produced from the few view and/or low intensity projections results in low-quality images that are suffering from severe artifacts when using conventional...... information about the solution. The training images must be reliable and application-specific. This PhD project aims at providing a mathematical and computational framework for the use of training sets as non-parametric priors for the solution in tomographic image reconstruction. Through an unsupervised...

  5. Evaluation of paranasal sinus mucosa in coal worker's pneumoconiosis - A computed tomographic study

    Energy Technology Data Exchange (ETDEWEB)

    Ozdemir, H.; Altin, R.; Mahmutyazicioglu, K.; Kart, L.; Uzun, L.; Savranlar, A.; Davcanci, H.; Gundogdu, S. [Zonguldak Karaelmas University, Zonguldak (Turkey). School of Medicine

    2004-09-01

    Objective: To evaluate by computed tomographic scanning the paranasal mucosal changes of coal workers with and without pneumoconiosis. Methods: Examination of images and scores from paranasal computed tomographic scans. The study participants were 26 coal workers with pneumoconiosis, 29 coal workers without pneumoconiosis, and 20 controls. All were men. The extent and patterns of inflamatory paranasal sinus disease were evaluated on computed, tomographic scans by 2 radiologists using the terminology and definitions of Newman and associates. Results: Interobserver agreement for the presence of abnormalities was from good to excellent (K, 0.63-0.89). The mucosal scores of individuals and groups were higher for coal workers than for control subjects. Both scores were significantly higher in the pneumoconiosis group than in the 2 other groups. Conclusions: This study shows that paranasal sinuses were affected more severely in coal workers than in control subjects. In coal workers with pneumoconiosis, the affection was most severe. The relationship between coal dust exposure and paranasal mucosal changes needs further study.

  6. Receptivity to e-cigarette marketing, harm perceptions, and e-cigarette use.

    Science.gov (United States)

    Pokhrel, Pallav; Fagan, Pebbles; Kehl, Lisa; Herzog, Thaddeus A

    2015-01-01

    To test whether exposure and receptivity to e-cigarette marketing are associated with recent e-cigarette use among young adults through increased beliefs that e-cigarettes are less harmful than cigarettes. Data were collected from 307 multiethnic 4- and 2-year college students; approximately equal proportions of current, never, and former cigarette smokers [mean age = 23.5 (SD = 5.5); 65% female]. Higher receptivity to e-cigarette marketing was associated with perceptions that e-cigarettes are less harmful than cigarettes, which in turn, were associated with higher recent e-cigarette use. The findings provide preliminary support to the proposition that marketing of e-cigarettes as safer alternatives to cigarettes or cessation aids is associated with increased e-cigarette use among young adults. The findings have implications for development of e-cigarette regulations.

  7. The Anion Paradox in Sodium Taste Reception: Resolution by Voltage-Clamp Studies

    Science.gov (United States)

    Ye, Qing; Heck, Gerard L.; Desimone, John A.

    1991-11-01

    Sodium salts are potent taste stimuli, but their effectiveness is markedly dependent on the anion, with chloride yielding the greatest response. The cellular mechanisms that mediate this phenomenon are not known. This "anion paradox" has been resolved by considering the field potential that is generated by restricted electrodiffusion of the anion through paracellular shunts between taste-bud cells. Neural responses to sodium chloride, sodium acetate, and sodium gluconate were studied while the field potential was voltage-clamped. Clamping at electronegative values eliminated the anion effect, whereas clamping at electropositive potentials exaggerated it. Thus, field potentials across the lingual epithelium modulate taste reception, indicating that the functional unit of taste reception includes the taste cell and its paracellular microenvironment.

  8. Computed tomographic study in children with microcephaly

    International Nuclear Information System (INIS)

    Ito, Masatoshi; Okuno, Takehiko; Mikawa, Haruki

    1989-01-01

    Computed tomographic (CT) brain scanning was performed on fifty-eight infants and children with microcephaly. CT scans were useful for detecting unsuspected brain lesions and for diagnosing underlying diseases. The head size did not correlate with the CT findings, the degree of mental retardation, or the existence of motor disturbance or epilepsy. On the other hand, the CT findings were correlated with the degree of mental retardation, and the existence of motor disturbance or epilepsy. CT scans were useful for determining the prognosis of the microcephaly. (author)

  9. Receptivity to free stream acoustic disturbances due to a roughness element on a flat plate

    OpenAIRE

    Ashour, Osama Naim

    1993-01-01

    The boundary-layer receptivity resulting from acoustic forcing over a flat plate with a surface irregularity is investigated. The unsteady free-stream disturbances couple with the steady perturbations resulting from the surface irregularity to form a traveling-wave mode. The resonance condition necessary for receptivity requires a forcing at a wave number equal to that of the Tollmien-Schlichting (TS) eigenmode and a frequency equal to that of the free-stream acoustic disturban...

  10. Monitoring of health of trees by gamma-ray tomographic scanners and the first Kanpur error theorem

    International Nuclear Information System (INIS)

    Verma, Ruchi; Razdan, Mayuri; Quraishi, A.M.; Munshi, Prabhat

    2004-01-01

    CT scanners produce nondestructively images of a given cross-section with the help of radiation source-detector system and a suitable tomographic reconstruction algorithm. These CT images have inherent error associated with them and for unknown objects it is not possible to calculate it directly. Careful application of the first Kanpur theorem, however, gives an indirect estimate of the inaccuracy of these images. An interesting outcome of this theorem is monitoring of health of trees. (author)

  11. Spatiotemporal profiles of receptive fields of neurons in the lateral posterior nucleus of the cat LP-pulvinar complex.

    Science.gov (United States)

    Piché, Marilyse; Thomas, Sébastien; Casanova, Christian

    2015-10-01

    The pulvinar is the largest extrageniculate thalamic visual nucleus in mammals. It establishes reciprocal connections with virtually all visual cortexes and likely plays a role in transthalamic cortico-cortical communication. In cats, the lateral posterior nucleus (LP) of the LP-pulvinar complex can be subdivided in two subregions, the lateral (LPl) and medial (LPm) parts, which receive a predominant input from the striate cortex and the superior colliculus, respectively. Here, we revisit the receptive field structure of LPl and LPm cells in anesthetized cats by determining their first-order spatiotemporal profiles through reverse correlation analysis following sparse noise stimulation. Our data reveal the existence of previously unidentified receptive field profiles in the LP nucleus both in space and time domains. While some cells responded to only one stimulus polarity, the majority of neurons had receptive fields comprised of bright and dark responsive subfields. For these neurons, dark subfields' size was larger than that of bright subfields. A variety of receptive field spatial organization types were identified, ranging from totally overlapped to segregated bright and dark subfields. In the time domain, a large spectrum of activity overlap was found, from cells with temporally coinciding subfield activity to neurons with distinct, time-dissociated subfield peak activity windows. We also found LP neurons with space-time inseparable receptive fields and neurons with multiple activity periods. Finally, a substantial degree of homology was found between LPl and LPm first-order receptive field spatiotemporal profiles, suggesting a high integration of cortical and subcortical inputs within the LP-pulvinar complex. Copyright © 2015 the American Physiological Society.

  12. Reproducibility of temporomandibular joint tomography. Influence of shifted X-ray beam and tomographic focal plane on reproducibility

    International Nuclear Information System (INIS)

    Saito, Masashi

    1999-01-01

    Proper tomographic focal plane and x-ray beam direction are the most important factors to obtain accurate images of the temporomandibular joint (TMJ). In this study, to clarify the magnitude of effect of these two factors on the image quality. We evaluated the reproducibility of tomograms by measuring the distortion when the x-ray beam was shifted from the correct center of the object. The effects of the deviation of the tomographic focal plane on image quality were evaluated by the MTF (Modulation Transfer Function). Two types of tomograms, one the plane type, the other the rotational type were used in this study. A TMJ model was made from Teflon for the purpose of evaluation by shifting the x-ray beam. The x-ray images were obtained by tilting the model from 0 to 10 degrees 2-degree increments. These x-ray images were processed for computer image analysis, and then the distance between condyle and the joint space was measured. To evaluate the influence of the shifted tomographic focal plane on image sharpness, the x-ray images from each setting were analyzed by MTF. To obtain the MTF, ''knife-edge'' made from Pb was used. The images were scanned with a microdensitometer at the central focal plane, and 0, 0.5, 1 mm away respectively. The density curves were analyzed by Fourier analysis and the MTF was calculated. The reproducibility of images became worse by shifting the x-ray beam. This tendency was similar for both tomograms. Object characteristics such as anterior and posterior portion of the joint space affected the deterioration of reproducibility of the tomography. The deviation of the tomographic focal plane also decreased the reproducibility of the x-ray images. The rotational type showed a better MTF, but it became seriously unfavorable with slight changes of the tomographic focal plane. Contrarily, the plane type showed a lower MTF, but the image was stable with shifting of the tomographic focal plane. (author)

  13. A general purpose tomographic program with combined inversions

    International Nuclear Information System (INIS)

    Xu Wenbin; Dong Jiafu; Li Fanzhu

    1996-01-01

    A general tomographic program has been developed by combining the Bessel expansion with the Zernicke expansion. It is useful for studying of the magnetic island structure of the tearing mode and in reconstructing the density profiles of impurities in tokamak plasmas. This combined method have the advantages of both expansions, i.e. there will be no spurious images in the edge and it will be of high inverse precision in the center of plasma

  14. Development of a X-ray micro-tomograph and its application to reservoir rocks characterization

    International Nuclear Information System (INIS)

    Ferreira de Paiva, R.

    1995-10-01

    We describe the construction and application to studies in three dimensions of a laboratory micro-tomograph for the characterisation of heterogeneous solids at the scale of a few microns. The system is based on an electron microprobe and a two dimensional X-ray detector. The use of a low beam divergence for image acquisition allows use of simple and rapid reconstruction software whilst retaining reasonable acquisition times. Spatial resolutions of better than 3 microns in radiography and 10 microns in tomography are obtained. The applications of microtomography in the petroleum industry are illustrated by the study of fibre orientation in polymer composites, of the distribution of minerals and pore space in reservoir rocks, and of the interaction of salt water with a model porous medium. A correction for X-ray beam hardening is described and used to obtain improved discrimination of the phases present in the sample. In the case of a North Sea reservoir rock we show the possibility to distinguish quartz, feldspar and in certain zone kaolinite. The representativeness of the tomographic reconstruction is demonstrated by comparing the surface of the reconstructed specimen with corresponding images obtained in scanning electron microscopy. (author). 58 refs., 10 tabs., 71 photos

  15. The media's reception of the risk associated with radioactive disasters

    International Nuclear Information System (INIS)

    Vettenranta, S.

    1996-01-01

    There is an urgent need to develop methodologies to examine the response by the media to radioactive disasters. 'Reception study' is a new research approach in the field of mass communication, studying how the viewers construct meaning from TV news. This ongoing reception study explores how fifteen respondents, all involved in the Chernobyl disaster in 1986, recall and interpret TV news coverage nine years after the accident. The main aim is to discover how the news affects the recipients' interpretations of a disaster and what kind of thoughts, reactions and associations risk messages provoke in retrospect, in the present and in the beliefs about the future. The initial findings indicate that the Chernobyl news on TV was mainly based on technical rationality, while viewers construct meaning founded on symbolic, cultural rationality. The transmission of catastrophe news is not just a matter of responding to the information needs of the public. Denotative risk messages simultaneously convey connotative, symbolic resonance of risk on a metaphysical level. (author)

  16. Early expressive and receptive language trajectories in high-risk infant siblings of children with autism spectrum disorder

    Directory of Open Access Journals (Sweden)

    Julie Longard

    2017-11-01

    Full Text Available Background & aims In response to limited research on early language development in infants at high risk for Autism Spectrum Disorder (ASD, the current prospective study examined early expressive and receptive language trajectories in familial high-risk (HR infants who were and were not later diagnosed with ASD (HR-ASD and HR-N, respectively, and low-risk (LR controls with no family history of ASD. Methods Participants were 523 children (371 HR siblings, 56% boys; 152 LR controls, 52% boys followed from age 6 or 12 months to 36 months. Based on independent, best-estimate clinical diagnoses at 36 months, HR participants were classified as HR-ASD (n = 94; 69% boys, or HR-N (n = 277; 52% boys; the sample also included 152 LR controls (52% boys. Expressive and receptive language trajectories were examined based on corresponding domain standard scores on the Mullen Scales of Early Learning ( MSEL at 6, 12, 24, and 36 months. In the combined sample of HR and LR infants, semi-parametric group-based modeling was used to identify distinct trajectories in MSEL standard scores. Results A 3-group solution provided optimal fit to variation in both expressive and receptive language, with the following patterns of scores: (1 inclining from average to above average, (2 stable-average, and (3 declining from average to well below average. For both expressive and receptive language, membership in these trajectories was related to 3-year diagnostic outcomes. Conclusions Although HR-ASD, HR-N, and LR control infants were in each trajectory group, membership in the declining trajectory (expressive and/or receptive was associated with an ASD diagnosis. Implications Evidence of declining trajectories in either expressive or receptive language may be a risk marker for ASD in a high-risk sample.

  17. In vitro receptivity of carbonate rocks to endolithic lichen-forming aposymbionts.

    Science.gov (United States)

    Favero-Longo, Sergio E; Borghi, Alessandro; Tretiach, Mauro; Piervittori, Rosanna

    2009-10-01

    Sterile cultured isolates of lichen-forming aposymbionts have not yet been used to investigate lichen-rock interactions under controlled conditions. In this study mycobionts and photobiont of the endolithic lichens Bagliettoa baldensis and Bagliettoa marmorea were isolated and inoculated with coupons of one limestone and four marbles commonly employed in the Cultural Heritage framework. After one year of incubation, microscopic observations of polished cross-sections were performed to verify if the typical colonization patterns observed in the field may be reproduced in vitro and to evaluate the receptivity of the five lithotypes to endolithic lichens. The mycobionts of the two species developed both on the surface of and within all the lithotypes, showing different penetration pathways which depend on mineralogical and structural features and highlight different receptivity. By contrast, algae inoculated with the coupons did not penetrate them. Observations suggest that the hyphal penetration along intrinsic discontinuities of rocks is a relatively fast phenomenon when these organisms are generally considered as slow-growing. Samples from limestone outcrops and abandoned marble quarries, colonized by the same species or other representatives of Verrucariaceae, showed penetration pathways intriguingly similar to those reproduced in vitro and highlighted that lichen-driven erosion processes only increase the availability of hyphal passageways after a long-term colonization. These results show that in vitro incubation of sterile cultured lichen-forming ascomycetes with rock coupons is a practicable experimental system to investigate the lichen-rock interactions under controlled conditions and, together with analysis in situ, may support decisions on conservative treatments of historical and cultural significant stone substrata.

  18. Computer tomographic investigation of ancient Egyptian mummies

    Energy Technology Data Exchange (ETDEWEB)

    Huebner, K H; Pahl, W M

    1981-08-01

    Radiological and computer tomographic examinations of Egyptian mummies have been carried out at the Institute of Anthropology and Human Genetics from 1975 to 1978. These have demonstrated the value of CT in medical archaeology. It enables one to study the soft tissues, the skin (if bandaged), the muscles and any organs retained in situ for magical or religious reason. Measurements of attenuation values indicate the materials which were used for mummifying the skin and organs. Characteristic examples are described and the early results of these examinations are discussed.

  19. Computer tomographic investigation of ancient Egyptian mummies

    International Nuclear Information System (INIS)

    Huebner, K.H.; Pahl, W.M.; Tuebingen Univ.

    1981-01-01

    Radiological and computer tomographic examinations of Egyptian mummies have been carried out at the Institute of Anthropology and Human Genetics from 1975 to 1978. These have demonstrated the value of CT in medical archaeology. It enables one to study the soft tissues, the skin (if bandaged), the muscles and any organs retained in situ for magical or religious reason. Measurements of attenuation values indicate the materials which were used for mummifying the skin and organs. Characteristic examples are described and the early results of these examinations are discussed. (orig.) [de

  20. Receptivity to E-cigarette Marketing, Harm Perceptions, and E-cigarette Use

    Science.gov (United States)

    Pokhrel, Pallav; Fagan, Pebbles; Kehl, Lisa; Herzog, Thaddeus A.

    2016-01-01

    Objective To test whether exposure and receptivity to e-cigarette marketing are associated with recent e-cigarette use among young adults through increased beliefs that e-cigarettes are less harmful than cigarettes. Methods Data were collected from 307 multiethnic 4- and 2-year college students; approximately equal proportions of current, never, and former cigarette smokers [mean age = 23.5 (SD = 5.5); 65% female]. Results Higher receptivity to e-cigarette marketing was associated with perceptions that e-cigarettes are less harmful than cigarettes, which in turn, were associated with higher recent e-cigarette use. Conclusions The findings provide preliminary support to the proposition that marketing of e-cigarettes as safer alternatives to cigarettes or cessation aids is associated with increased e-cigarette use among young adults. The findings have implications for development of e-cigarette regulations. PMID:25290604

  1. Tomographic Constraints on High-Energy Neutrinos of Hadronuclear Origin.

    Science.gov (United States)

    Ando, Shin'ichiro; Tamborra, Irene; Zandanel, Fabio

    2015-11-27

    Mounting evidence suggests that the TeV-PeV neutrino flux detected by the IceCube telescope has mainly an extragalactic origin. If such neutrinos are primarily produced by a single class of astrophysical sources via hadronuclear (pp) interactions, a similar flux of gamma-ray photons is expected. For the first time, we employ tomographic constraints to pinpoint the origin of the IceCube neutrino events by analyzing recent measurements of the cross correlation between the distribution of GeV gamma rays, detected by the Fermi satellite, and several galaxy catalogs in different redshift ranges. We find that the corresponding bounds on the neutrino luminosity density are up to 1 order of magnitude tighter than those obtained by using only the spectrum of the gamma-ray background, especially for sources with mild redshift evolution. In particular, our method excludes any hadronuclear source with a spectrum softer than E^{-2.1} as a main component of the neutrino background, if its evolution is slower than (1+z)^{3}. Starburst galaxies, if able to accelerate and confine cosmic rays efficiently, satisfy both spectral and tomographic constraints.

  2. Computed tomographic findings of cerebral paragonimiasis

    International Nuclear Information System (INIS)

    Sung, Nak Kwan; Nam, Kyung Jin; Park, Churl Min; Eun, Chung Kie; Lee, Sun Wha

    1983-01-01

    Paragonimiasis is widely distributed in Far East and Southeast Asia, particularly in Korea. The central nervous system is the most frequent location for paragonimiasis outside the lungs. We analyzed the computed tomographic findings of 17 cases which were diagnosed pathologically and clinically as cerebral paragonimiasis. The results were as follows: 1. The ratio of male to female was 10 : 7 and about 88% of cases were under the age of 40 years. 2. The common locations of cerebral paragonimiasis were the occipital (12 cases) and temporal (11 cases) lobes. 3. Precontrast CT findings of cerebral paragonimiasis were low density with calcifications in 6 cases, low and isodensities in 4 cases, mixed densities in 3 cases, only low density in 2 cases and only calcification in 2 cases. Hydrocephalus (7 cases), mass effect (6 cases), atrophic change (6 cases) and cyst formation (3 cases) were associated. 4. The shape of calcifications in CT scan were soap-bubble or ring in 6 cases, nodular or oval in 6 cases, stipple in 4 cases and amorphous conglomerated in 2 cases. 5. The contrast -enhanced 8 cases were 5 ring or rim like, 2 nodular and 1 irregular enhancements, while 9 cases were not enhanced

  3. Psychological Models of Art Reception must be Empirically Grounded

    DEFF Research Database (Denmark)

    Nadal, Marcos; Vartanian, Oshin; Skov, Martin

    2017-01-01

    We commend Menninghaus et al. for tackling the role of negative emotions in art reception. However, their model suffers from shortcomings that reduce its applicability to empirical studies of the arts: poor use of evidence, lack of integration with other models, and limited derivation of testable...... hypotheses. We argue that theories about art experiences should be based on empirical evidence....

  4. The 1623 Plan for Global Governance: the obscure history of its reception

    Directory of Open Access Journals (Sweden)

    GERMAN A. DE LA REZA

    2015-12-01

    Full Text Available Abstract In the present article we analyze the characteristics and the reception of the first plan for global governance, the New Cyneas by Émeric Crucé. With this goal in mind, we examine the history of its readings and the possible influence on the Duke of Sully's project for European confederation, the case most often cited by historians of ideas. Our analysis takes into consideration the 17th century reception, the scant dissemination of the work and the possible causes of its limited impact. Our conclusions support, on the one hand, the novelty of Crucé's principal ideas, and on the other, their limited impact over the time with the exception of the period surrounding the creation of the League of Nations.

  5. Computed tomographic diagnosis of abdominal abscess in childhood

    International Nuclear Information System (INIS)

    Kuhn, J.P.; Berger, P.E.

    1980-01-01

    Twenty-eight children suspected clinically of having an abdominal abscess were examined by CT. Eighteen had gallium 67 citrate scans and 22 had ultrasound studies. Computed tomography was found to be the most accurate test for diagnosis and evaluation of an abscess and the computed tomographic appearance of abscess is illustrated. However, because of cost factors, radiation dose, and clinical considerations, computed tomography is not always the first modality of choice in evaluating a suspected abdominal abscess [fr

  6. Dense velocity reconstruction from tomographic PTV with material derivatives

    Science.gov (United States)

    Schneiders, Jan F. G.; Scarano, Fulvio

    2016-09-01

    A method is proposed to reconstruct the instantaneous velocity field from time-resolved volumetric particle tracking velocimetry (PTV, e.g., 3D-PTV, tomographic PTV and Shake-the-Box), employing both the instantaneous velocity and the velocity material derivative of the sparse tracer particles. The constraint to the measured temporal derivative of the PTV particle tracks improves the consistency of the reconstructed velocity field. The method is christened as pouring time into space, as it leverages temporal information to increase the spatial resolution of volumetric PTV measurements. This approach becomes relevant in cases where the spatial resolution is limited by the seeding concentration. The method solves an optimization problem to find the vorticity and velocity fields that minimize a cost function, which includes next to instantaneous velocity, also the velocity material derivative. The velocity and its material derivative are related through the vorticity transport equation, and the cost function is minimized using the limited-memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) algorithm. The procedure is assessed numerically with a simulated PTV experiment in a turbulent boundary layer from a direct numerical simulation (DNS). The experimental validation considers a tomographic particle image velocimetry (PIV) experiment in a similar turbulent boundary layer and the additional case of a jet flow. The proposed technique (`vortex-in-cell plus', VIC+) is compared to tomographic PIV analysis (3D iterative cross-correlation), PTV interpolation methods (linear and adaptive Gaussian windowing) and to vortex-in-cell (VIC) interpolation without the material derivative. A visible increase in resolved details in the turbulent structures is obtained with the VIC+ approach, both in numerical simulations and experiments. This results in a more accurate determination of the turbulent stresses distribution in turbulent boundary layer investigations. Data from a jet

  7. E-learn Computed Tomographic Angiography

    DEFF Research Database (Denmark)

    Havsteen, Inger; Christensen, Anders; Nielsen, Jens K

    2012-01-01

    BACKGROUND: Computed tomographic angiography (CTA) is widely available in emergency rooms to assess acute stroke patients. To standardize readings and educate new readers, we developed a 3-step e-learning tool based on the test-teach-retest methodology in 2 acute stroke scenarios: vascular...... occlusion and "spot sign" in acute intracerebral hemorrhage. We hypothesized that an e-learning program enhances reading skills in physicians of varying experience. METHODS: We developed an HTML-based program with a teaching segment and 2 matching test segments. Tests were taken before and after...... sign correctly 69% before versus 92% after teaching (P = .009) and reported a median self-perceived diagnostic certainty of 50% versus 75% (P = .030). Self-perceived diagnostic certainty revealed no significant increase for vascular occlusion. CONCLUSIONS: The e-learning program is a useful educational...

  8. The public reception of the Research Assessment Exercise 1996.

    Directory of Open Access Journals (Sweden)

    Julian Warner

    1998-01-01

    Full Text Available This paper reviews the public reception of the Research Assessment Exercise 1996 (RAE from its announcement in December 1996 to the decline of discussion at end May 1997. A model for diffusion of the RAE is established which distinguishes extra-communal (or exoteric from intra-communal (or esoteric media. The different characteristics of each medium and the changing nature of the discussion over time are considered. Different themes are distinguished in the public reception of the RAE: the spatial distribution of research; the organisation of universities; disciplinary differences in understanding; a perceived conflict between research and teaching; the development of a culture of accountability; and analogies with the organisation of professional football. In conclusion, it is suggested that the RAE and its effects can be more fully considered from the perspective of scholarly communication and understandings of the development of knowledge than it has been by previous contributions in information science, which have concentrated on the possibility of more efficient implementation of existing processes. A fundamental responsibility for funding councils is also identified: to promote the overall health of university education and research, while establishing meaningful differentiations between units.

  9. Seeing, wanting, owning: the relationship between receptivity to tobacco marketing and smoking susceptibility in young people

    Science.gov (United States)

    Feighery, E.; Borzekowski, D.; Schooler, C.; Flora, J.

    1998-01-01

    OBJECTIVE—To assess the effect of the tobacco industry's marketing practices on adolescents by examining the relationship between their receptivity to these practices and their susceptibility to start smoking.
DESIGN—Paper-and-pencil surveys measuring association with other smokers, exposure to tobacco industry marketing strategies, experience with smoking, and resolve not to smoke in the future.
SETTING—25 randomly selected classrooms in five middle schools in San Jose, California.
SUBJECTS—571 seventh graders with an average age of 13 years and 8 months; 57% were female. Forty-five per cent of the students were Asian, 38% were Hispanic, 12% were white, and 5% were black.
MAIN OUTCOME MEASURES—Exposure to social influences, receptivity to marketing strategies, susceptibility to start smoking.
RESULTS—About 70% of the participants indicated at least moderate receptivity to tobacco marketing materials. Children who are more receptive are also more susceptible to start smoking. In addition to demographics and social influences, receptivity to tobacco marketing materials was found to be strongly associated with susceptibility.
CONCLUSIONS—Tobacco companies conduct marketing campaigns that effectively capture teenage attention and stimulate desire for their promotional items. These marketing strategies may function to move young teenagers from non-smoking status toward regular use of tobacco. Our results demonstrate that there is a clear association between tobacco marketing practices and youngsters' susceptibility to smoke. The findings, along with other research, provide compelling support for regulating the manner in which tobacco products are marketed, to protect young people from the tobacco industry's strategies to reach them.


Keywords: adolescents; advertising; smoking initiation PMID:9789929

  10. Reasons between effective doses for tomographic and mathematical models due to external exposition by photons

    International Nuclear Information System (INIS)

    Kramer, R.; Khoury, H.J.; Yoriyaz, H.; Lima, F.R.A.; Loureiro, E.C.M.

    2005-01-01

    The development of Monte Carlo codes and new and sophisticated tomographic human models, or based on voxel, motivated the ICRP to propose a revision of the traditional exposition models, which have been used to calculate doses on organs and tissues using mathematical phantoms MIRD-type 5. This article presents calculations made with tomographic phantoms MAX (Male Adult voXel) and FAX (Female Adult voXel), recently developed and also, for comparison, with ADAM and Eve mathematician phantoms. All models were coupled to the EGS4 and MCNP4 codes for full body external irradiation by photons. It were simulated expositions AP, PA and rotational for energies varying between 10 keV and 10 MeV. The effective calculated doses were compared separately to evaluate: the replacement of the Monte Carlo code; the composition of the tissues and the replacement of tomographic phantoms by mathematical ones. Effective doses calculated results indicate that for external exposures by photons to introduce models based on voxels can cause a reduction of about 10% to the energies considered in this study

  11. Tomographic reconstruction of OH* chemiluminescence in two interacting turbulent flames

    International Nuclear Information System (INIS)

    Worth, Nicholas A; Dawson, James R

    2013-01-01

    The tomographic reconstruction of OH* chemiluminescence was performed on two interacting turbulent premixed bluff-body stabilized flames under steady flow conditions and acoustic excitation. These measurements elucidate the complex three-dimensional (3D) vortex–flame interactions which have previously not been accessible. The experiment was performed using a single camera and intensifier, with multiple views acquired by repositioning the camera, permitting calculation of the mean and phase-averaged volumetric OH* distributions. The reconstructed flame structure and phase-averaged dynamics are compared with OH planar laser-induced fluorescence and flame surface density measurements for the first time. The volumetric data revealed that the large-scale vortex–flame structures formed along the shear layers of each flame collide when the two flames meet, resulting in complex 3D flame structures in between the two flames. With a fairly simple experimental setup, it is shown that the tomographic reconstruction of OH* chemiluminescence in forced flames is a powerful tool that can yield important physical insights into large-scale 3D flame dynamics that are important in combustion instability. (paper)

  12. Thanatophoric dysplasia: case report of an autopsy complemented by postmortem computed tomographic study

    Directory of Open Access Journals (Sweden)

    Éber Emanuel Mayoral

    2014-06-01

    Full Text Available Thanatophoric dysplasia (TD is one of the most common lethal skeletal dysplasias, which was first designated as thanatophoric dwarfism and described in 1967. The authors report a case of a Caucasian girl with TD, born to a 31-year-old woman without comorbidities. The newborn presented respiratory distress immediately after delivery, progressing to death in less than 2 hours. An autopsy was carried out after postmortem tomographic examination. The autopsy findings depicted extensive malformations of the skeletal system and the brain. The aim of this report is to discuss the pathogenesis and correlate the morphologic features of TD that were disclosed at the tomography and the autopsy.

  13. Non-Cooperative Bistatic SAR Clock Drift Compensation for Tomographic Acquisitions

    Directory of Open Access Journals (Sweden)

    Mario Azcueta

    2017-10-01

    Full Text Available In the last years, an important amount of research has been headed towards the measurement of above-ground forest biomass with polarimetric Synthetic Aperture Radar (SAR tomography techniques. This has motivated the proposal of future bistatic SAR missions, like the recent non-cooperative SAOCOM-CS and PARSIFAL from CONAE and ESA. It is well known that the quality of SAR tomography is directly related to the phase accuracy of the interferometer that, in the case of non-cooperative systems, can be particularly affected by the relative drift between onboard clocks. In this letter, we provide insight on the impact of the clock drift error on bistatic interferometry, as well as propose a correction algorithm to compensate its effect. The accuracy of the compensation is tested on simulated acquisitions over volumetric targets, estimating the final impact on tomographic profiles.

  14. Cross-Language Associations in the Development of Preschoolers' Receptive and Expressive Vocabulary.

    Science.gov (United States)

    Maier, Michelle F; Bohlmann, Natalie L; Palacios, Natalia A

    The increasing population of dual language learners (DLLs) entering preschool classrooms highlights a continued need for research on the development of dual language acquisition, and specifically vocabulary skills, in this age group. This study describes young DLL children's ( N = 177) vocabulary development in both English and Spanish simultaneously, and how vocabulary skills in each language relate to one another, during a contextual shift that places greater emphasis on the acquisition of academic English language skills. Findings demonstrated that DLL preschoolers made gains in vocabulary in both languages with more change evidenced in receptive, in comparison to expressive, vocabulary as well as in English in comparison to Spanish. When examining whether children's vocabulary scores in one language at the beginning of preschool interact with their vocabulary scores in the other language to predict vocabulary growth, no significant associations were found for receptive vocabulary. In contrast, the interaction between initial English and Spanish expressive vocabulary scores was negatively related to growth in English expressive vocabulary. This cross-language association suggests that children who have low expressive vocabulary skills in both languages tend to grow faster in their English expressive vocabulary. The study extends previous work on dual language development by examining growth in expressive and receptive vocabulary in both English and Spanish. It also provides suggestions for future work to inform a more comprehensive understanding of DLL children's development in both languages.

  15. X-ray tomographic and laminographic microscopy (XTM, XLM) using synchrotron radiation

    International Nuclear Information System (INIS)

    Wyss, P.; Obrist, A.; Hofmann, J.; Luethi, T.; Sennhauser, U.; Thurner, P.; Stampanoni, M.; Abela, R.; Patterson, B.; Mueller, R.

    2003-01-01

    Inner structures of composite materials, components or tissues have to be characterised with micrometer and even submicrometer resolution. It is often highly desirable that specimens stay unchanged after a first characterization to allow meaningful subsequent tests. This justifies major efforts for an ongoing improvement of nondestructive radiographical and tomographical methods for morphological characterization. Radiography and tomography as well as laminography can fulfill these requirements. X-ray sources and detectors have been improved. This applies for synchrotron-beamline systems as well as for tube based systems. A novel detector concept has been implemented in the XTM station at the SLS of the PSI in Villigen, Switzerland. This microtomography station at the SLS has started its operation in spring 2002. A selection of results related to industrial and scientific applications is presented in this contribution. Special emphasis will be given to first results of tomography with limited numbers of projections which is comparable to laminography. This method allows to characterise e.g. ribbons of tissue under load

  16. Tomographic capabilities of the new GEM based SXR diagnostic of WEST

    Science.gov (United States)

    Jardin, A.; Mazon, D.; O'Mullane, M.; Mlynar, J.; Loffelmann, V.; Imrisek, M.; Chernyshova, M.; Czarski, T.; Kasprowicz, G.; Wojenski, A.; Bourdelle, C.; Malard, P.

    2016-07-01

    The tokamak WEST (Tungsten Environment in Steady-State Tokamak) will start operating by the end of 2016 as a test bed for the ITER divertor components in long pulse operation. In this context, radiative cooling of heavy impurities like tungsten (W) in the Soft X-ray (SXR) range [0.1 keV; 20 keV] is a critical issue for the plasma core performances. Thus reliable tools are required to monitor the local impurity density and avoid W accumulation. The WEST SXR diagnostic will be equipped with two new GEM (Gas Electron Multiplier) based poloidal cameras allowing to perform 2D tomographic reconstructions in tunable energy bands. In this paper tomographic capabilities of the Minimum Fisher Information (MFI) algorithm developed for Tore Supra and upgraded for WEST are investigated, in particular through a set of emissivity phantoms and the standard WEST scenario including reconstruction errors, influence of noise as well as computational time.

  17. Optical Computed-Tomographic Microscope for Three-Dimensional Quantitative Histology

    Directory of Open Access Journals (Sweden)

    Ravil Chamgoulov

    2004-01-01

    Full Text Available A novel optical computed‐tomographic microscope has been developed allowing quantitative three‐dimensional (3D imaging and analysis of fixed pathological material. Rather than a conventional two‐dimensional (2D image, the instrument produces a 3D representation of fixed absorption‐stained material, from which quantitative histopathological features can be measured more accurately. The accurate quantification of these features is critically important in disease diagnosis and the clinical classification of cancer. The system consists of two high NA objective lenses, a light source, a digital spatial light modulator (DMD, by Texas Instrument, an x–y stage, and a CCD detector. The DMD, positioned at the back pupil‐plane of the illumination objective, is employed to illuminate the specimen with parallel rays at any desired angle. The system uses a modification of the convolution backprojection algorithm for reconstruction. In contrast to fluorescent images acquired by a confocal microscope, this instrument produces 3D images of absorption stained material. Microscopic 3D volume reconstructions of absorption‐stained cells have been demonstrated. Reconstructed 3D images of individual cells and tissue can be cut virtually with the distance between the axial slices less than 0.5 μm.

  18. Tomographic reconstruction of transverse phase space from turn-by-turn profile data

    CERN Document Server

    Hancock, S; Lindroos, M

    1999-01-01

    Tomographic methods have the potential for useful application in beam diagnostics. The tomographic reconstruction of transverse phase space density from turn-by-turn profile data has been studied with particular attention to the effects of dispersion and chromaticity. It is shown that the modified Algebraic Reconstruction Technique (ART) that deals successfully with the problem of non-linear motion in the longitudinal plane cannot, in general, be extended to cover the transverse case. Instead, an approach is proposed in which the effect of dispersion is deconvoluted from the measured profiles before the phase space picture is reconstructed using either the modified ART algorithm or the inverse Radon Transform. This requires an accurate knowledge of the momentum distribution of the beam and the modified ART reconstruction of longitudinal phase space density yields just such information. The method has been tested extensively with simulated data.

  19. Detectability in the presence of computed tomographic reconstruction noise

    International Nuclear Information System (INIS)

    Hanson, K.M.

    1977-01-01

    The multitude of commercial computed tomographic (CT) scanners which have recently been introduced for use in diagnostic radiology has given rise to a need to compare these different machines in terms of image quality and dose to the patient. It is therefore desirable to arrive at a figure of merit for a CT image which gives a measure of the diagnostic efficacy of that image. This figure of merit may well be dependent upon the specific visual task being performed. It is clearly important that the capabilities and deficiencies of the human observer as well as the interface between man and machine, namely the viewing system, be taken into account in formulating the figure of merit. Since the CT reconstruction is the result of computer processing, it is possible to use this processing to alter the characteristics of the displayed images. This image processing may improve or degrade the figure of merit

  20. Engagement with dietary fibre and receptiveness to resistant starch in Australia.

    Science.gov (United States)

    Mohr, Philip; Quinn, Sinéad; Morell, Matthew; Topping, David

    2010-11-01

    To investigate community engagement with the health benefits of dietary fibre (DF) and its potential as a framework for the promotion of increased consumption of resistant starch (RS). A nationwide postal Food and Health Survey conducted in Australia by CSIRO Human Nutrition. Adults aged 18 years and above, selected at random from the Australian Electoral Roll (n 849). A cross-sectional design was employed to analyse ratings of (i) the importance of various RS health and functional claims and (ii) receptiveness to different foods as RS delivery vehicles, according to the respondents' level of fibre engagement as classified under the Precaution Adoption Process Model (PAPM) of Health Behaviour. There was a high level of recognition (89·5 %) of DF as being important for health. Significant gender differences were found for ratings of RS attributes and RS delivery options. Women were both more fibre-engaged than men and more receptive than men to RS and its potential benefits. Ratings of the acceptability of several foods as means of delivering RS revealed a general preference for healthy staples over indulgences, with the margin between acceptability of staples and indulgences increasing markedly with increased fibre engagement. Application of the PAPM to awareness of DF reveals a ready-made target group for health messages about RS and pockets of differential potential receptiveness. The findings support the promotion of RS as providing health benefits of DF with the added reduction of risk of serious disease, its delivery through healthy staples and the targeting of messages at both fibre-engaged individuals and women in general.