WorldWideScience

Sample records for tld-100 para iones

  1. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation; Eficiencias termoluminiscentes relativas de TLD-100 para iones de nitrogeno respecto de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Concha S, K. [UNAM, Facultad de Ciencias, 04510 Mexico D.F. (Mexico); Avila, O. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Gamboa de Buen, I. [ICN-UNAM, 04510 Mexico D.F. (Mexico); Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E. [IFUNAM, 04510 Mexico D.F. (Mexico)

    2004-07-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of {sup 60} Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E{sub 1} energy (4.8 MeV) and E{sub 2} (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  2. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation

    International Nuclear Information System (INIS)

    Concha S, K.; Avila, O.; Gamboa de Buen, I.; Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E.

    2004-01-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of 60 Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E 1 energy (4.8 MeV) and E 2 (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  3. Response of TLD-100 LiF dosimeters for X-rays of low energies; Respuesta de dosimetros de TLD-100 de LiF para rayos X de bajas energias

    Energy Technology Data Exchange (ETDEWEB)

    Bonzi, E. V.; Mainardi, R. T. [Universidad Nacional de Cordoba, Facultad de Matematica, Astronomia y Fisica, Av. Haya de la Torre y Av. Medina Allende s/n, Ciudad Universitaria, X5016LEA Cordoba (Argentina)

    2011-10-15

    In diverse practical applications as the existent in radiological clinics, industrial facilities and research laboratories, the solid state dosimeters are used for the measure of the different types of ionizing radiations. At the present time dosimeters are manufactured with different types of materials that present thermoluminescent properties, to the effects of determining the absorbed radiation dose. Under these conditions, the radiation dose is determined integrated in all the range of energies of the beam of X-rays, since it assumes that the response of these dosimeters is lineal with the energy of the photons or radiant particles. Because interest exists in advancing in the development of a determination method in the way of the X-rays spectrum emitted by a tube of those used in diagnostic or therapy, we have measured the response of TLD-100 LiF dosimeters for low energies, minor at 60 keV, for a several group of these dosimeters. (Author)

  4. Determination of the TLD-100 physical parameters

    International Nuclear Information System (INIS)

    Paucar J, J.; Picon C, C.

    1998-01-01

    This study was realized in the Physics service at the Radiotherapy Department of the National Institute of Neoplasic Diseases in Lima, Peru, it was determined the activation energy, the kinetic order and the frequency factor of the fifth peak of the TLD-100 thermoluminescent spectra using different algorithms. This was carried out in parallel with the implementation and design of a software and an interface associated with the Tl lecturer which allows a semiautomatic control for a thermoluminescent lecturer process. (Author)

  5. Application of the Cavity theory in the calibration of the powder TLD-100 for energies of {sup 60} Co, {sup 137} Cs, {sup 192} Ir and RX 50, 250 k Vp; Aplicacion de la Teoria de la Cavidad en la calibracion de polvo TLD-100 para energias de {sup 60} Co, {sup 137} Cs, {sup 192} Ir y RX 50, 250 kVp

    Energy Technology Data Exchange (ETDEWEB)

    Loaiza C, S.P. [UAEM, Programa de Maestria en Fisica Medica, 50180, Toluca, Estado de Mexico (Mexico); Alvarez R, J.T. [ININ, 52750, Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: sandraplc_04@yahoo.com.mx

    2006-07-01

    A powder lot TLD-100 (LiF:Mg,Ti) in absorbed dose terms in water D{sub w} for the following radiation sources: {sup 60} Co, {sup 137} Cs and RX 50 and 250 k Vp is calibrated; to continuation is made a lineal interpolation of the TLD response in function of the effective energy of the sources to calibrate a source of {sup 192} Ir. The calibration of those fields in D{sub w} are carried out with aid of the Bragg-Gray cavity theory, the one which finds implicit in the following protocols: IAEA-TRS 398 for the {sup 60} Co and the AAPM TG61 for X Rays of 50 and 250 k Vp. Additionally the AAPM protocol TG43 to determine the D{sub w} in function of the kerma intensity S{sub k} in the case of the {sup 137} Cs is used. The calibration curves for the response of the TLD-100 R{sub TLD} vs D{sub w}, corresponding to each one of the sources already mentioned are constructed. The R{sub TLD} vs D{sub w} by least heavy square by means of a second order polynomial that corrects the supralineality of the response is adjusted. The curves are validated by lack of LOF adjustment and by the Anderson Darling normality test. Later the factors of sensitivity (F{sub s}) for the sources of {sup 192} Ir: Micro Selectron and Vari Source are interpolated, used respectively in the A and B hospitals for treatments of brachytherapy of high dose rate (HDR), the expanded uncertainties associated to the D{sub w} and F{sub s} are also determined. Finally, an acrylic phantom and a couple of capsules are already sent to the hospitals mentioned, to verify a nominal D{sub w} of 2 Gy, in a case an underestimate in 5.5% in the imparted D{sub w} and in other an overestimation in a range of -1.5 to -8.0% was obtained. The obtained results in this work establish the bases for the development of a national dosimetric quality control program for brachytherapy of HDR with sources of {sup 192} Ir. (Author)

  6. Determination of the TLD-100 physical parameters; Determinacion de parametros fisicos del TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Paucar J, J.; Picon C, C. [Instituto Nacional de Enfermedades Neoplasicas. INEN. Av. Angamos Este 2520, Lima 34 (Peru)

    1998-12-31

    This study was realized in the Physics service at the Radiotherapy Department of the National Institute of Neoplasic Diseases in Lima, Peru, it was determined the activation energy, the kinetic order and the frequency factor of the fifth peak of the TLD-100 thermoluminescent spectra using different algorithms. This was carried out in parallel with the implementation and design of a software and an interface associated with the Tl lecturer which allows a semiautomatic control for a thermoluminescent lecturer process. (Author)

  7. Characterization of TLD-100 in powders for dosimetric quality control of {sup 192} Ir sources used in brachytherapy of high dose rate; Caracterizacion de TLD-100 en polvo para control de calidad dosimetrico de fuentes de Ir{sup 192} usadas en braquiterapia de alta tasa de dosis

    Energy Technology Data Exchange (ETDEWEB)

    Loaiza C, S.P

    2007-07-01

    The Secondary Standard Dosimetric at the National Institute of Nuclear Research (ININ) calibrated a lot of powdered TLD-100 (LiF:Mg,Ti) in terms of absorbed dose to water D{sub w} for the energy of: {sup 60}Co, {sup 137C}s, X rays of 250 and 50 kVp. Later on, it is carried out an interpolation of the calibration for the energy of the {sup 192}Ir. This calibration is part of a dosimetric quality control program, to solve the problems of traceability for the measurements carried out by the users of {sup 192}Ir sources employed in the treatments of High Dose Rate Brachytherapy (HDR) at the Mexican Republic. The calibrations of the radiation beams are made with the following protocols: IAEA TRS-398 for the {sup 60}Co for D{sub w}, using a secondary standard ionization chamber PTW N30013 calibrated in D{sub w} by the National Research Council (NRC, Canada). AAPM TG-43 for D{sub w} in terms of the strength kerma Sk, calibrating this last one quantity for the {sup 137}Cs radioactive source, with a well chamber HDR 1000 PLUS traceable to the University of Wisconsin (US). AAPM TG-61 for X ray of 250 and 50 kVp for D{sub w} start to Ka using field standard a Farmer chamber PTW 30001 traceable to K for the Central Laboratory of Electric Industries (CLEI, France). The calibration curves (CC) they built for the response of the powder TLD: R{sub TLD} vs D{sub w}: For the energy of {sup 60}Co, {sup 137}Cs, X rays of 250 and 50 kVp. Fitting them with the least square method weighed by means of a polynomial of second grade that corrects the supra linearity of the response. iii. Each one of the curves was validated with a test by lack of fitting and for the Anderson Darling normality test, using the software MINITAB in both cases. iv. The sensibility factor (F{sub s}) for each energy corresponds to the slope of the CC, v. The F{sub s} for the two {sup 192}Ir sources used are interpolated: one for a Micro Selectron source and the other one a Vari Source source. Finally, a couple of

  8. Phototransference in LiF (TLD-100) at low temperatures

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da; Caldas, L.V.E.

    1990-01-01

    Phototransference experiments were performed with UV light of 250, 310 and 380 nm in LiF (TLD-100) at liquid nitrogen temperature with the aim of observing thermoluminescence emission peaks. (A.C.A.S.) [pt

  9. TLD-100 and Radiochromic Dye Film in Medical Dosimetry

    International Nuclear Information System (INIS)

    Mercado-Uribe, H.

    2006-01-01

    TLD-100 and radiochromic dye films are two types of the dosimeters most used in the medical physics area. Both are secondary detectors and operate in a different way and in different dose measurement ranges. The use of TLD-100 is based on the thermoluminescent process, and the RDF in the optical density change when has been exposed to an irradiation field previously. In this work it is analyzed in a general way, the advantages and characteristics of these detectors and the reasons of the great increase in their use in the last decades

  10. Fractional order of kinetics in LiF-TLD 100

    International Nuclear Information System (INIS)

    Moharil, S.V.

    1984-01-01

    In a recent letter, it has been argued that the non-first-order kinetics for LiF-TLD 100 obtained by Kathuria and Sunta (J. Phys. D: Appl. Phys. 12, 1573) is an artefact of their experimental set-up. In this letter it is shown that this is not the case. (author)

  11. Use of MCNP to compare the response of dose deposited in the TLD 100, TLD 600 and TLD 700 in radiation fields due to {sup 60}Co and {sup 241}AmBe source; Uso do MCNP para comparacao das respostas de dose depositada nos TLD 100, TLD 600 e TLD 700 em campos de irradiacao devido a fontes de {sup 60}Co e {sup 241}AmBe

    Energy Technology Data Exchange (ETDEWEB)

    Cavalieri, Tassio A.; Castro, Vinicius A.; Siqueira, Paulo T.D., E-mail: tassio.cavalieri@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2012-08-15

    The successes of Boron Neutron Capture Therapy (BNCT) depend on the ability to deliver an adequate irradiation field to the target cells. Neutron beams used in BNCT are mostly driven from reactors and therefore, not only have a neutron energy range which far exceeds the thermal region but also do have a great gamma component. Beam characterization and dosimetry are consequently one of the essential procedures to be overcome to properly apply this technique. One of the methods currently used in mixed field (field containing both neutron and gamma) characterization, lies on the use of a pair of detectors with distinct responses to each beam component. But this technique needs to be better understood of how each thermoluminescent dosimeter (TLD) behaves in a mixed field or in a pure field. This work presents the results of a set of simulations performed in order to analyze the response of three ordinary types of TLDs - TLD 100, TLD 600 and TLD 700 - submitted to different irradiation fields from a Cobalt source and an Americium-Beryllium source inside a paraffin disk. And is also a possible method for performing the selection and calibration of theses TLDs. (author)

  12. Indoor gamma radiation monitoring In Rawalpindi, Pakistan using TLD100

    International Nuclear Information System (INIS)

    Azam, Sana; Tufail, Muhammad; Sohail, Muhammad

    2008-01-01

    Full text: Natural radioactivity originates from extraterrestrial sources as well as from radioactive elements in earth's crust. The amount of radioactivity varies from place to place and with altitude. The aim of this study was to observe the indoor radiation level in Rawalpindi using TLD. For this purpose LiF:Mg:Ti (TLD100) chips were used. Chips were annealed and then calibrated using different sources and the calibration factor obtained by using Cs137 source was selected for dose estimation. Its value was 0.1403 μGy/TL response. Rawalpindi categorized into six regions. In each region, 5 cemented houses were selected and TLD 100 chips were placed at a distance of 0.5 m from ground the level. Chips were properly covered to protect them from ultraviolet light and moisture and were placed for three months. The average annual indoor dose rate for Rawalpindi was estimated to be 392.105μGy/yr and average dose to be 97.65μGy. Therefore, the effective dose for population of Rawalpindi from indoor gamma radiation was estimated to be 313.68μSv/yr using an indoor occupancy factor of 80%. (author)

  13. Thermoluminescence and optical absorption comparative studies with TLD-100 and pure LiF

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da; Caldas, L.V.E.

    1988-07-01

    Optical absorption (OA) studies were carried out with LiF: Mg, Ti (TLD-100) and pure LiF exposed to X radiation, 77.4 C.kg -1 (3 x 10 5 R) with the aim of relating the thermoluminescent (TL) peaks presented by TLD-100 to its intrinsic and irradiation defects. After a 280 0 C thermal treatment for 15 minutes, an absorption band at 225 nm is observed in the TLD-100 OA spectrum. This band is not observed in the case of pure LiF. A correlation between TL peak 5 and the absorption band at 310 nm is established for TLD-100. These results agree with other publications and are explained. (author) [pt

  14. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative quantities ICRU, for external fields of beta radiation. Part II. I study of the angular response of personal dosemeters TLD-100 in secondary patron fields of beta radiation ({sup 90}Sr / {sup 90}Y); Medicion de dosis equivalente con dosimetros personales e instrumentos de proteccion radiologica en las nuevas magnitudes operativas ICRU, para campos de radiacion beta externos. Parte II. Estudio de la respuesta angular de dosimetros personales TLD-100 en campos patrones secundarios de radiacion beta ({sup 90}Sr/{sup 90}Y)

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1994-01-15

    The objective of this work is to carry out one of the possible ones test type for personal dosemeters TLD, under the recomendations of the ICRU 39, ICRU 43 and the draft of the norm ISO 6980,(1992), with the purpose of verifying the capacity of these detectors to carry out the operative unit: H' (0.07;{alpha}). Since H' (O. 07;{alpha}) this defined one in an expanded field, one of these tests type consist on determining the angular response of these detectors. 20 personal dosemeters TLD-100 was used, (card marks: Harshaw, Model: G-1, with two glasses of TLD-100 absorbed in teflon; the portadosemeters has two windows, a free one and another with a filter of Pb of 171.0 mg cm{sup -2}); these dosemeters they were previously selected, [to see, {sup S}tudy of the Homogeneity of the response of Personal Dosemeters (Cards G-l, TLD-100) in Radiation of Countrysides of {sup 60}Co{sup ,} J.T. Alvarez R. Technician Report GSR/IT/0001/94].The irradiations to effectued in secondary countryside of radiation beta of {sup 90}Sr/{sup 90}Y. The study was undertaken by means of an experimental design of blocks random that contemplate the following variables: intensity of the radiation source, (1850 MBq and 74 MBq); position of irradiation, (four positions); incidence of angle of the radiation (0, 15, 30, 45, 60 and 75 grades) and the absorbed dose in air, (0.005, 0.010, 0.020, 0.050 and 0.100 Gy). Then null hypothesis it was to suppose that there was not difference among the stockings of each treatment, to used the statistical of Duncan to carry out tests of stockings at a level of significance of 5%.These tests of stockings throw the following results in those variables of the experimental design: The irradiations carried out so much with the source pattern secondary of {sup 90}Sr/{sup 90}Y of 1850 MBq and of 74 MBq, they are equivalent reason why they can be used indistinctly. The responses of each one of the glasses of the card are strongly anisotropic for each glass

  15. Calibration of TLD-100 powder for energies of {sup 60} Co, {sup 137} Cs, {sup 192} Ir and RX of 250, 50 kV{sub p} in absorbed dose in water with dosimetric quality control purposes for brachytherapy of high dose rate; Calibracion de polvo TLD-100 para energias de {sup 60} Co, {sup 137} Cs, {sup 192} Ir y RX de 250, 50 kVp en dosis absorbida en agua con fines de control de calidad dosimetrico para braquiterapia de alta tasa de dosis

    Energy Technology Data Exchange (ETDEWEB)

    Loaiza C, S.P. [Programa de Maestria en Fisica Medica, Universidad Autonoma del Estado de Mexico, Paseo Tollocan S/N, esquina con Jesus Carranza, Colonia Moderna de la Cruz, 50180 Toluca, Edo. de Mexico (Mexico); Alvarez R, J.T. [Laboratorio Secundario de Calibracion Dosimetrica LSCD, Departamento de Metrologia, ININ, Carretera Federal Mexico Toluca S/N, La Marquesa, 52750 Ocoyoacac, Edo. de Mexico (Mexico)

    2006-07-01

    To help solve the traceability and quality control dosimetric problems for the users of {sup 192} Ir sources in the Mexican Republic, the Secondary Standard Dosimetric Laboratory at ININ to calibrated a batch of powder TLD- 100 (LiF: Mg,Ti) in terms of absorbed dose to water D{sub w} for the following radiation sources: {sup 60} Co, {sup 137C}s and RX 250 and 50 k Vp. Later on, the calibration is interpolated to obtain the {sup 192} Ir. The calibration radiation field is carried out with the following protocols: For the {sup 60} Co, IAEA TRS 398 protocol employing a secondary standard Farmer chamber PTW N30013, calibrated on D{sub w} at the NRC (Canada). For {sup 137} Cs the AAPM TG 43 protocol is used, in terms of air kerma strength S{sub k} determined by the air kerma K{sub a}, measured with a secondary standard chamber type thimble NE2611 traceable to the NIST (USA). For Rays X 250 and 50 k Vp, the protocol AAPM TG 61 using a tertiary standard Farmer chamber PTW 30001, with traceability to the LCIE (France) on air kerma K{sub a}. The calibration curves are built for the TLD response R{sub TLD} vs D{sub w}, they are fitted by means of a least squares fit technique with a second degree polynomial that corrects the supra linearity response. The curves are validated by the lack of fit test, and the Anderson Darling normality test. Later on, the sensibility factors are interpolated for the sources of {sup 192} Ir: Micro Selectron and Vari Source. Two capsules are sent to two hospitals to verify a nominal D{sub w} = 2 Gy, in the first one an underestimate of the D{sub w} is obtained, and in other one an overestimation is presented. Finally, the expanded uncertainty associated to D{sub w} and the F{sub s} are calculated. (Author)

  16. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E. [UNAM, Facultad de Ciencias, 04510 Mexico D.F. (Mexico)

    2007-07-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  17. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.

    2007-01-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  18. Reproducibility study of TLD-100 dosimeters for {sup 122}I seeds used in brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Zeituni, Carlos A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Universidade Presbiteriana Mackenzie, Sao Paulo, SP (Brazil); E-mail: czeituni@ipen.br; Moura, Eduardo S. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Faculdade Oswaldo Cruz, Sao Paulo, SP (Brazil); Manzoli, Jose E. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Universidade Sao Judas Tadeu, Sao Paulo, SP (Brazil); Terremoto, Luis A.A.; Rostelato, Maria Elisa C.M. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2007-07-01

    In order to provide the dosimetry for {sup 125}I seed production in Brazil, Harshaw thermoluminescent dosimeters (TLD-100) will be used. Even if measurements with TLD-100 of the same batch of fabrication are performed, the precision of the response will not be the same. As a consequence, they must be measured one by one. This paper presents the calculation methodology for selection procedure to TLD-100 dosimeter used, embracing 143 TLD-100 dosimeters prepared by Harshaw Company on December 19th, 2005. These dosimeters are LiF type with a micro-cube (1 mm x 1 mm x 1 mm) shape. The annealing procedure used for these dosimeters consists of annealing the TLD dosimeters at 400 deg C for 65 minutes using a PC controlled annealing oven. This procedure is followed by an oven-typical cooling down profile to about 100 deg C for 127 minutes. The pre-readout thermal stabilization was used and it consists of an annealing at 100 deg C for 15 minutes. Irradiations were performed using 36 {sup 125}I seeds with activity of 0,623 mCi (23,05 MBq) on October 20th, 2006 for approximately 150 minutes, to guarantee a minimum of 5 Gy absorbed dose in each dosimeter. Different evanescence times have been used. These complete procedures were carried out four times in order to compare the data and minimize the systematic error. (author)

  19. Reproducibility study of TLD-100 dosimeters for 122I seeds used in brachytherapy

    International Nuclear Information System (INIS)

    Zeituni, Carlos A.; Moura, Eduardo S.; Manzoli, Jose E.; Terremoto, Luis A.A.; Rostelato, Maria Elisa C.M.

    2007-01-01

    In order to provide the dosimetry for 125 I seed production in Brazil, Harshaw thermoluminescent dosimeters (TLD-100) will be used. Even if measurements with TLD-100 of the same batch of fabrication are performed, the precision of the response will not be the same. As a consequence, they must be measured one by one. This paper presents the calculation methodology for selection procedure to TLD-100 dosimeter used, embracing 143 TLD-100 dosimeters prepared by Harshaw Company on December 19th, 2005. These dosimeters are LiF type with a micro-cube (1 mm x 1 mm x 1 mm) shape. The annealing procedure used for these dosimeters consists of annealing the TLD dosimeters at 400 deg C for 65 minutes using a PC controlled annealing oven. This procedure is followed by an oven-typical cooling down profile to about 100 deg C for 127 minutes. The pre-readout thermal stabilization was used and it consists of an annealing at 100 deg C for 15 minutes. Irradiations were performed using 36 125 I seeds with activity of 0,623 mCi (23,05 MBq) on October 20th, 2006 for approximately 150 minutes, to guarantee a minimum of 5 Gy absorbed dose in each dosimeter. Different evanescence times have been used. These complete procedures were carried out four times in order to compare the data and minimize the systematic error. (author)

  20. Response of TLD-100{sup TM} microtubes to two RQR3 quality radiation beams; Resposta de microcubos de TLD-100{sup TM} a dois feixes de qualidade RQR 3

    Energy Technology Data Exchange (ETDEWEB)

    Nunes, M.G.; Villani, D.; Almeida, S.B.; Vivolo, V.; Yoriyaz, H., E-mail: dvillani@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Louis, G.M.J. [Universidad Nacional Autonoma de Mexico (Mexico)

    2016-07-01

    The present work compares the response of TLD-100{sup TM} microcubes to two RQR 3 diagnostic radiology reference quality radiation beams, defined by IEC-61267 norm, aiming to evaluate the detectability of TLD-100{sup TM} energy dependence reported in literature within the same reference quality radiation range. TLD-100{sup TM} microcubes reproducibility is assessed through the response of a second set of TLD-100{sup TM} microcubes, evaluated in a second thermoluminescence reader, to the RQR 3 diagnostic radiology reference quality radiation beam implemented at the Laboratorio de Calibracao de Instrumentos of IPEN, Sao Paulo, SP, Brazil. The dependence of TLD-100{sup TM} microcubes TL response was not detectable in these conditions and the reproducibility of the measurements is 90,2%. (author)

  1. Verification or treatment planning system of radiotherapy using TLD-100; Verificacion de los sistemas de planificacion de tratamiento de radioterapia empleando TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Pinuela, J., E-mail: jcpinuela@hotmail.co [Hospital Central de Maracay (Venezuela, Bolivarian Republic of). Servicio de Radioterapia

    2010-07-01

    The evaluation of the treatment planning system (TPS) used in radiotherapy Precise Plan, was carried out using TLD-100 dosimeters, comparing the dose obtained with an ionization chamber. The TLD-100 were calibrated using secondary standard of SSDL, selecting dosimeters which had a standard deviation less than 1% for dosimeter calibration and less than 5% for dosimeter of field, for the tests conducted in TPS, The Alderson Phantom was used to evaluate the wedge and bolus, and Lucy 3D allowed us to evaluate correspondence of CT numbers, volume expansion, beam shaping, precise dose and beam weigh assignment. It was observed that the results of Lucy 3D were within the values expected except the volume expansion process with more than 10% difference, the evaluation of beam modulators systems with wedges and bolus as beam shaping yielded values within the expected with variations less than 5% and to assess the supply of specific doses, it was observed that the values obtained were precise and accurate since the same variation was less than 0.5% for the test. The importance of assessing the TPS lies in our country there is no procedure to verify that system and these tests provide a basis for future comparisons. (author)

  2. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative magnitudes ICRU, for external fields of beta radiation. Part I. Study of the homogeneity of the response personal dosemeters leaves (cards G-1, TLD-100), in radiation fields of Co{sub 60}; Medicion de dosis equivalente con dosimetros personales e instrumentos de proteccion radiologica en las nuevas magnitudes operativas ICRU, para campos de radiacion beta externos. Parte I. Estudio de la homogeneidad de la respuesta dosimetros personales (tarjetas G-1, TLD-100), en campos de radiacion de Co{sub 60}

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1994-01-15

    A sample of 40 composed personal dosemeters by cards model: G-l, (each card is made up of two TLD-100 crystals encapsulated in teflon), Harshaw trademark; those personal dosemeters present a free window and another with a filter of A1 of 171.7 mg cm{sup -2} of mass thickness.The objective of the work is to select of this sample of 40 personal dosemeters a population with the same stocking and standard deviation. The technique used is that of comparison of stockings, (ANOVA; Variance Analysis, when samples of the same one were had size; and/or GLM, Widespread Lineal Models, when the samples were of different size), by means of the use of those Duncan statistics, SNK, Tukey, Gabriel; the results are validated proving the kindness of adjustment of the experimental data to a Normal distribution by means of the Shapiro-Wilks statistics.The experimental design used consists on a test of two vias: a via is the variable card with two levels, (crystal 1 and 2), the other via is the variable irradiation position with four levels, (LS=left superior, SR= right superior, LI= left Inferior, IR = right inferior). The irradiations carried out in blocks of four personal dosemeters in a gamma radiation beam range of Cobalt 60; carrying out three repetitions of the design. With object of proving the homogeneity of the filter of A1 in those personal dosemeters the experimental design was executed for those cards without personal dosemeters.They were also carried out tests of stockings to the readings of bottom and sensibility of the reader equipment, (Harshaw, model marks 2271), certain that doesn{sup t} exist differences for sequence of reading, but if in the stockings of the sensibility, (they were 4 different populations). The responses of the dosemeters were corrected subtracting him the reading correspondence of bottom and by sensibility of the reader equipment before subjecting them to the tests of stockings mentioned. Of the results of the tests of stockings for the cards with

  3. Evaluation of LiF:Mg,Ti (TLD-100 for Intraoperative Electron Radiation Therapy Quality Assurance.

    Directory of Open Access Journals (Sweden)

    Raffaele Liuzzi

    Full Text Available Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs response to intraoperative electron radiation therapy (IOERT beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2-12 cGy/pulse during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for quality assurance. The TLDs feature many advantages such as a small detector size and close tissue equivalence that make them attractive for IOERT as in vivo dosimeters.LiF:Mg,Ti dosimeters (TLD-100 were irradiated with different IOERT electron beam energies (5, 7 and 9 MeV and with a 6 MV conventional photon beam. For each energy, the TLDs were irradiated in the dose range of 0-10 Gy in step of 2 Gy. Regression analysis was performed to establish the response variation of thermoluminescent signals with dose and energy.The TLD-100 dose-response curves were obtained. In the dose range of 0-10 Gy, the calibration curve was confirmed to be linear for the conventional photon beam. In the same dose region, the quadratic model performs better than the linear model when high dose-per-pulse electron beams were used (F test; p<0.05.This study demonstrates that the TLD dose response, for doses ≤10 Gy, has a parabolic behavior in high dose-per-pulse electron beams. TLD-100 can be useful detectors for IOERT patient dosimetry if a proper calibration is provided.

  4. Equipment, measurement technique and annealing of LiF (TLD-100) in TL-dosimetry

    International Nuclear Information System (INIS)

    Unhjem, J.F.

    1987-01-01

    Results of variations in reference light, dark current, TL-signal and total background signal during a read-out series of LiF (TLD-100) crystals are presented. Also two annealing procedures are compared. The results indicate a good signal-to-noise ratio, E(S)/σ, and that a new annealing procedure takes less time to carry out. Because of the time-saving effect and the high signal-to-noise ratio, the new annealing procedure can be recommended

  5. Quality control of the breast cancer treatments on Hdr brachytherapy with TLD-100

    International Nuclear Information System (INIS)

    Torres H, F.; De la Espriella V, N.; Sanchez C, A.

    2014-01-01

    An anthropomorphic Phantom, a female trunk, was built with a natural bone structure and experimental material coated, glycerin and water-based material called JJT to build soft tissue equivalent to the muscle of human tissue, and a polymer (styrofoam) to build the lung as critical organ to simulate the treatment of breast cancer, with high dose rate brachytherapy (Hdr) and sources of Ir-192. The treatments were planned and calculated for the critical organ: Lung, and injury of 2 cm in diameter in breast with Micro Selectron Hdr system and the software Plato Brachytherapy V 14.1 of the Nucletron (Netherlands) which uses the standard protocol of radiotherapy for brachytherapy treatments. The dose experimentally measured with dosimeters TLD-100 LiF: Mg; Ti, which were previously calibrated, were placed in the same positions and bodies mentioned above, with less than 5% uncertainty. The reading dosimeters was carried out in a Harshaw TLD 4500. The results obtained for calculated treatments, using the standard simulator, and the experimental with TLD-100, show a high concordance, as they are on average a ± 1.1% making process becomes in a quality control of this type of treatments. (Author)

  6. Quality control of the breast cancer treatments on Hdr brachytherapy with TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Torres H, F. [Universidad de Cordoba, Materials and Applied Physics Group, 230002 Monteria, Cordoba (Colombia); De la Espriella V, N. [Universidad de Cordoba, Grupo Avanzado de Materiales y Sistemas Complejos, 230002 Monteria, Cordoba (Colombia); Sanchez C, A., E-mail: franciscotorreshoyos@yahoo.com [Universidad de Cordoba, Departamento de Enfermeria, 230002 Monteria, Cordoba (Colombia)

    2014-07-01

    An anthropomorphic Phantom, a female trunk, was built with a natural bone structure and experimental material coated, glycerin and water-based material called JJT to build soft tissue equivalent to the muscle of human tissue, and a polymer (styrofoam) to build the lung as critical organ to simulate the treatment of breast cancer, with high dose rate brachytherapy (Hdr) and sources of Ir-192. The treatments were planned and calculated for the critical organ: Lung, and injury of 2 cm in diameter in breast with Micro Selectron Hdr system and the software Plato Brachytherapy V 14.1 of the Nucletron (Netherlands) which uses the standard protocol of radiotherapy for brachytherapy treatments. The dose experimentally measured with dosimeters TLD-100 LiF: Mg; Ti, which were previously calibrated, were placed in the same positions and bodies mentioned above, with less than 5% uncertainty. The reading dosimeters was carried out in a Harshaw TLD 4500. The results obtained for calculated treatments, using the standard simulator, and the experimental with TLD-100, show a high concordance, as they are on average a ± 1.1% making process becomes in a quality control of this type of treatments. (Author)

  7. Environmental dosimetry system based on LiF : Mg, Ti (TLD-100)

    International Nuclear Information System (INIS)

    Saez Vergara, J.C.

    1990-01-01

    The report presents the various tests carried out to the characterize a thermoluminescence environmental dosimetry systems, using the phosphor LiF:mg,Ti (TLD-100) in chip form. The holder has been specifically designed in order to obtain simplicity in the operation and to assure correct measurements in terms of the new operational quantities in radiation protection (ICRU-1985). Some topics in TLD Environmental Monitoring are discussed (Dark Current, Reference Light, Zero Reading, Free-in-Air or Phantom Calibration, Fading Correction, Transit Dose, etc.), and the proposed solutions are exposed. The tests performed have been designed to conform with the different existing international Standards and Recommendations (ANSI : N545-1975; IEC: Draft 45B-1987, ISO : DP 8034-19849. The data from an European Interlaboratory Programm (EUR-8932) have been used to evaluate the performance : the TLD System presented is among the best systems using TLD-100. The results obtained in the characterization (linearity, repeatability, detection threshold, residue, angular response, stability of stored information, etc.) show the optimum performance of this dosimetric system in its application to environmental gamma dose monitoring. Based on these results, two operational procedures have been developed for the application of this Dosimetric System, specially in Quality Assurance Monitoring Programs around Nuclear Plants in Spain. (author)

  8. On the determination of the post-irradiation time from the glow curve of TLD-100

    International Nuclear Information System (INIS)

    Weinstein, M.; German, U.; Dubinsky, S.; Alfassi, Z.B.

    2003-01-01

    The ratio of peak 3 to the sum of peaks 4 + 5 in TLD-100 was measured for various pre-irradiation and post-irradiation time periods, under conditions characteristic of routine personal dosimetry. It was confirmed that the value of this ratio depends only on the elapsed time between the prior readout and the present one, independent of the moment when the irradiation took place during the total time interval (storage time). This effect indicates that fading of peak 3 seems to be due mainly to changes in the unoccupied traps, and not to decay of trapped charges, being almost independent of the presence of electrons or holes in the traps. This observation leads to the conclusion that the suggestions in the past to use the decay of peak 3 in TLD-100 for the measurement of the elapsed time between irradiation and readout may have been wrong. On the other hand, the decay of peak 2 can be used to measure the elapsed time from irradiation, since the rate of decay is different when related to pre-irradiation and post-irradiation times, indicating a much higher decay rate of the trapped charges (Randall-Wilkins decay). However, because of the fast decay rate of peak 2, its use for determination of the elapsed time since irradiation is of little practical significance. (author)

  9. Characterization of TLD-100 micro-cubes for use in small field dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Peña-Jiménez, Salvador, E-mail: zoid-9861@yahoo.com.mx; Gamboa-deBuen, Isabel, E-mail: gamboa@nucleares.unam.mx [Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Av. Universidad 3000, 04510 DF (Mexico); Lárraga-Gutiérrez, José Manuel, E-mail: jose.larraga.gtz@gmail.com, E-mail: amanda.garcia.g@gmail.com; García-Garduño, Olivia Amanda, E-mail: jose.larraga.gtz@gmail.com, E-mail: amanda.garcia.g@gmail.com [Laboratorio de Física Médica, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Av. Insurgentes Sur 3877, 14269 DF (Mexico)

    2014-11-07

    At present there are no international regulations for the management of millimeter scale fields and there are no suggestions for a reference detector to perform the characterization and dose determination for unconventional radiation beams (small fields) so that the dosimetry of small fields remains an open research field worldwide because these fields are used in radiotherapy treatments. Sensitivity factors and reproducibility of TLD-100 micro-cubes (1×1×1 mm3) were determinate irradiating the dosimeters with a 6 MV beam in a linear accelerator dedicated to radiosurgery at the Instituto Nacional de Neurología y Neurocirugía (INNN). Thermoluminescent response as a function of dose was determined for doses in water between 0.5 and 3 Gy and two field sizes (2×2 cm2 and 10×10 cm2). It was found that the response is linear over the dose range studied and it does not depend on field size.

  10. Thermoluminescence of pure LiF and Lif (TLD-100) irradiated at room temperature

    International Nuclear Information System (INIS)

    Sagastibelza Chivite, F.

    1980-01-01

    The thermoluminescence of pure LiF and LiF (TLD-100) crystals irradiated at room temperature with x - or gamma-rays has been studied up to 460 degree centigree. For most of the glow peaks found the kinetics, preexponential factors and activation energies have been determined. These parameters have been obtained by means of the isothermal method. The study of the thermal annealing of the radiation induced F and Z centres has allow to show that there is a correlation among the glow peaks and the annealing stages of these centres. It is concluded that the F and Z - centres play the role of recombination centres for halogen interstitial atom thermally released from traps. Light emission occurs in this recombination. (Author) 120 refs

  11. Response of TLD-100 LiF dosimeters for X-rays of low energies

    International Nuclear Information System (INIS)

    Bonzi, E. V.; Mainardi, R. T.

    2011-10-01

    In diverse practical applications as the existent in radiological clinics, industrial facilities and research laboratories, the solid state dosimeters are used for the measure of the different types of ionizing radiations. At the present time dosimeters are manufactured with different types of materials that present thermoluminescent properties, to the effects of determining the absorbed radiation dose. Under these conditions, the radiation dose is determined integrated in all the range of energies of the beam of X-rays, since it assumes that the response of these dosimeters is lineal with the energy of the photons or radiant particles. Because interest exists in advancing in the development of a determination method in the way of the X-rays spectrum emitted by a tube of those used in diagnostic or therapy, we have measured the response of TLD-100 LiF dosimeters for low energies, minor at 60 keV, for a several group of these dosimeters. (Author)

  12. Thermoluminescent response of dosemeters TLD-100 exposed to distinct baker protocols, irradiation and reading

    International Nuclear Information System (INIS)

    Estrada E, D.

    2002-01-01

    The interest that motivated the realization of this work is the opposing discrepancy among the values of the efficiency thermoluminescent of heavy charged particles (PCP) regarding gamma radiation (η PCP , γ) reported in different works and gathered recently for Horowitz (Ho 01). The measures of relative thermoluminescent efficiency have importance in relation to the dosimetry associated to medical therapy with heavy charged particle. The measurement of η PCP , γ depends of multiple experimental factors. To understand this dependence it was quantified the effect of using different procedures experimental in the estimate of the relative thermoluminescent efficiency of dosemeters TLD-100 (LiF: Ti; Mg) for protons of 3 MeV regarding gamma rays of 60 Co (η PCP , γ), varying the lot, the presentation, the one baked and the team reader. When was used the same global procedure values they were obtained for (η PCP , γ) inside the interval [0.30, 0.58] for the peak 5 and [0.35, 0.76] for the total thermoluminescent signal (Tl). At the use different equipment, baked and lot are obtained maximum differences of 30%, 12% and 6% respectively in the values of (η PCP , γ) for the peak 5, and 25%, 28% and 7% for the total Tl signal. The changes more significant of 36% and 44% for peak 5 and total signal respectively are obtained when changing the presentation of the dosemeter. As a complementary investigation it was studied the distribution of the Tl signal of each peak in the deconvolution of the curve of brightness with regard to the total signal in exposed dosemeters to high fluence of protons (1x10 10 p/cm 2 ) varying the experimental protocol. It was found that the distribution of the Tl signal has a difference of the order of 5% when changing the used reading team. It was observed that the contribution of the peak 5 regarding the total signal are preserved when changing baked and that it results to be 8% greater for the presentation in dosemeters of 1 x 1 x 1 mm 3

  13. Difference between the mechanisms of peak formation of dosimetric TL(5) and 6 and 7 of TLD-100

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da; Caldas, L.V.E.

    1986-01-01

    It is studied the best model to explain the peak formation of TL 5,6 and 7 of TLD-100. The mission curves of the irradiated material were compared at environmental temperature and at 77 0 K. (E.G) [pt

  14. Use of TLD-100 to verify a dosimetric method for total electron skin irradiation

    International Nuclear Information System (INIS)

    Mesa, F.; Sosa, M.

    2007-01-01

    Full text: A clinical dosimetric method for generating a homogeneous field of radiation around of patients under treatment of total skin electron irradiation and its verification using thermoluminescent dosimetry is presented. The irradiations were performed utilizing a 6 MeV electron beam generated by a Varian Clinac 21EX linear accelerator installed in the oncology unit of the IMSS-Tl hospital in Leon. Levels of radiation for diverse adjustment performed in the treatment planning system of the lineal accelerator and registered to different treatment distances using a computerized water phantom system were studied. A large batch of TLD-100 chips calibrated in terms of air-kerma rate to the standard treatment distance and positioned in an anthropomorphic Alderson Random Phantom was used. Dose verification and comparison with the measurements made with the computerized system were analyzed. A single field electron beam for treatment of total skin irradiation was implemented. Preliminary results indicate that the levels of dose homogeneities were larger than 90% for distances up to 3.0 m. The results suggest that the method developed is a reliable for delivering an electron beam with significantly homogeneity for these treatments. Analyses and results of both thermoluminescent and computerized dosimetric system calibrations are also presented. (Author)

  15. Contribution to the optimization of individual dose measurement with TLD 100 using the TLD reader 6600

    International Nuclear Information System (INIS)

    RAFARAVAVY, R.

    2003-01-01

    In Madagascar, thermoluminescent dosimeters are used for individual monitoring of personal exposed by ionising radiation. This work consist to find the optimal condition of reading parameters, to calibrate the reader HARSHAW TLD 6600, and to determine the lower value of dose measurable by the TLD 100. The betters values of the temperature rate, the preheat time and the anneal time are respectively 21 0 C s - 1, 9s and 5s. Calibration of the reader HARSHAW TLD 6600 has permitted to have true value conventional. The calibration factors corresponding to the pastille of dosimeter which measure the whole body dose and the one which measure the skin dose are respectively 0.031nC μSv - 1 and 0.035 nCμSv-1. These calibration factors are tied to measured parameters values mentioned above. The lower limit of detection found is equal to 10.12 μSv. All measured values (background deduced) less than this lower limit of detection are considered as background fluctuation [fr

  16. Personal dosimetry TLD 100 in orthopedic surgeons exposed to ionizing radiation in Bogota - Colombia

    International Nuclear Information System (INIS)

    Sierra C, B. Y.; Jimenez, Y.; Plazas, M. C.; Eslava S, J.; Groot R, H.

    2014-08-01

    Orthopedic surgeons should be considered as professionals occupationally exposed to ionizing radiation, for using C arc (fluoroscope) an equipment of X type radiation emission, during surgical procedures for imaging generation. Some health institutes, use of C arc under uncontrolled circumstances, such a lack of dosimetry control, incomplete or absence of personnel protective elements and protective measures, which in turn, lead to a high exposition to the personnel. Materials and methods. Study of double match cohort by age and gender, was conducted, in four health institutions of second and third level of attention in Bogota city. Personal dosimetry measurements with TLD-100 dosimetry crystals in both cohorts and environmental dosimetry in each of operation rooms used for orthopedic procedures, were carry out during six months of follow up. Dosimetry crystals were read in a Harshaw 4500 - Bicron equipment, in the Medical Physics Laboratory of National University of Colombia. Results. Dosimetry measurements are compatibles with those of occupationally exposed personnel 3.44 mSv/6 m CI 95% (1.66-3.99), even does not overpass ICRP recommendations, are higher as were expect at the beginning of the study. The median of effective accumulative dose in thorax is 3,4 mSv CI 95% (1,66-3,99), higher in comparison with neck value 2,7 mSv CI 95% (1,73-3,80) and hand dosimetry 1,42 mSv CI 95% (0,96-2,34). Conclusions: Orthopedic surgeons should be considered occupational exposed to ionizing radiation, who has to accomplish to the radiological protection measures, dosimetric follow up and maintenance of the used X ray equipment. It was confirm throughout this study that dosimetry shows higher levels as expected at the beginning of the study, compatible with occupationally exposed personnel. (Author)

  17. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E.; Avila, O.; Rodriguez V, M. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico); Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E. [IFUNAM, 04500 Mexico D.F. (Mexico); Gamboa De Buen, I. [ICN-UNAM, 04500 Mexico D.F. (Mexico)

    2007-07-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  18. TLD-100 glow-curve deconvolution for the evaluation of the thermal stress and radiation damage effects

    International Nuclear Information System (INIS)

    Sabini, M.G.; Bucciolini, M.; Cuttone, G.; Guasti, A.; Mazzocchi, S.; Raffaele, L.

    2002-01-01

    In this work, the dose response of TLD-100 dosimeters has been studied in a 62 MeV clinical proton beams. The signal versus dose curve has been compared with the one measured in a 60 Co beam. Different experiments have been performed in order to observe the thermal stress and the radiation damage effects on the detector sensitivity. A LET dependence of the TL response has been observed. In order to get a physical interpretation of these effects, a computerised glow-curve deconvolution has been employed. The results of all the performed experiments and deconvolutions are extensively reported, and the TLD-100 possible fields of application in the clinical proton dosimetry are discussed

  19. TLD-100 glow-curve deconvolution for the evaluation of the thermal stress and radiation damage effects

    CERN Document Server

    Sabini, M G; Cuttone, G; Guasti, A; Mazzocchi, S; Raffaele, L

    2002-01-01

    In this work, the dose response of TLD-100 dosimeters has been studied in a 62 MeV clinical proton beams. The signal versus dose curve has been compared with the one measured in a sup 6 sup 0 Co beam. Different experiments have been performed in order to observe the thermal stress and the radiation damage effects on the detector sensitivity. A LET dependence of the TL response has been observed. In order to get a physical interpretation of these effects, a computerised glow-curve deconvolution has been employed. The results of all the performed experiments and deconvolutions are extensively reported, and the TLD-100 possible fields of application in the clinical proton dosimetry are discussed.

  20. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.; Avila, O.; Rodriguez V, M.; Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E.; Gamboa De Buen, I.

    2007-01-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  1. Comparison of the responses of TLD-100 and radiochromic films exposed to X-rays of low energy in a radiodiagnostic clinical treatment

    International Nuclear Information System (INIS)

    Castro, M.; Mesa, F.; Sosa, M.

    2007-01-01

    Full text: In this work a comparison of the responses of a TLD-100 and a radiochromic film exposed to a low energy X-ray beam is presented. X-rays in the range of 20 to 120 KV from a clinical machine at the radiodiagnostic unit of the IMSS-Tl hospital in Leon were used. The processes of calibration of both the TLD-100 and the radiochromic films are also discussed. (Author)

  2. Obtention of thermoluminescent efficiencies by means of irradiation of TLD-100 dosemeters with proton beams helium and carbon

    International Nuclear Information System (INIS)

    Avila, O.; Rodriguez V, M.; Aviles, P.; Gamboa de Buen, I.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E.

    2002-01-01

    In this work, the advances of a serial of measurements of relative efficiency thermoluminescent of heavy charged particles (PCP) with respect to gamma radiation for TLD-100, dosemeters of LiF: Mg,Ti manufactured by the Harshaw-Bicron company are reported. The PCP are essentials in the implementation of dosimetry associated with medical applications. The measurements before gamma radiation were carrying out using the Vickrad irradiator of the National Institute of Nuclear Research at dose of 1.663 Gy. The measures which are reported about protons, helium and carbon were realized using the Pelletron accelerator of the Physics Institute of the UNAM. (Author)

  3. Thermoluminescence of pure LiF and Lif (TLD-100) irradiated at room temperature; Termoluminiscencia en LiF puro y LiF dosimetrico (TLD-100), irradiados a temperatura ambiente

    Energy Technology Data Exchange (ETDEWEB)

    Sagastibelza Chivite, F.

    1980-07-01

    The thermoluminescence of pure LiF and LiF (TLD-100) crystals irradiated at room temperature with x - or gamma-rays has been studied up to 460 degree centigree. For most of the glow peaks found the kinetics, preexponential factors and activation energies have been determined. These parameters have been obtained by means of the isothermal method. The study of the thermal annealing of the radiation induced F and Z centres has allow to show that there is a correlation among the glow peaks and the annealing stages of these centres. It is concluded that the F and Z - centres play the role of recombination centres for halogen interstitial atom thermally released from traps. Light emission occurs in this recombination. (Author) 120 refs.

  4. Measure of the attenuation curve of a beam of X-rays with TLD-100 dosimeters of LiF; Medicion de la curva de atenuacion de un haz de rayos X con dosimetros TLD-100 de LiF

    Energy Technology Data Exchange (ETDEWEB)

    Bonzi, E. V.; Mainardi, R. T. [Universidad Nacional de Cordoba, Facultad de Matematica, Astronomia y Fisica, Av. Haya de la Torre y Av. Medina Allende s/n, Ciudad Universitaria, Cordoba (Argentina); Germanier, A. [Ministerio de Ciencia y Tecnologia, Ceprocor, Unidad de Estudios Fisicos, Alvarez de Arenas 230, X5004AAP Barrio Juniors, Cordoba (Argentina); Delgado, V. [Universidad Complutense de Madrid, Departamento de Fisica Medica, Ciudad Universitaria, 28040 Madrid (Spain)

    2011-10-15

    The attenuation curve of a beam of X-rays represents the beam intensity in function of the attenuator thickness interposed between the source and the detector. To know with the major possible precision the attenuation curve is indispensable in procedures of spectral reconstruction. Their periodic measuring also offers valuable information on the correct operation of a tube of X-rays, diagnostic or therapy, when not have a specific detector for that activity. In this work was measured the attenuation curve of a tube of X-rays operated to 50 kV and 0.5 ma, using existent elements in any diagnostic or therapy laboratory with radiations. In the measures commercial aluminum foil was used, bent until 24 times and thermoluminescent dosimeters TLD 100 - LiF. Also, for comparison, was measured this attenuation curve with an ionization chamber brand Capintec model 192. Was determined by X-rays fluorescence the composition of the aluminium foil, since the present elements in the alloy can to affect the form of the attenuation curve. It is interesting to observe that these elements are in very low proportion (ppm) that they do not alter the attenuation capacity of the pure aluminium. Finally in a precision balance we weigh a big piece (30 cm x 100 cm) of aluminium foil and we obtained the thickness in g/c m2. It is possible to obtain attenuation curves of a beam of X-rays, with a high precision procedure and reproducibility. The use of TLD-100 dosimeters of LiF or similar makes that this activity was also quick and simple. (Author)

  5. Analysis of read-out heating rate effects on the glow peaks of TLD-100 using WinGCF software

    Energy Technology Data Exchange (ETDEWEB)

    Bauk, Sabar, E-mail: sabar@usm.my [Physics Section, School of Distance Education, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Hussin, Siti Fatimah [School of Physics, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Alam, Md. Shah [Physics Section, School of Distance Education, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Physics Department, Shahjalal University of Science and Technology, Sylhet (Bangladesh)

    2016-01-22

    This study was done to analyze the effects of the read-out heating rate on the LiF:Mg,Ti (TLD-100) thermoluminescent dosimeters (TLD) glow peaks using WinGCF computer software. The TLDs were exposed to X-ray photons with a potential difference of 72 kVp and 200 mAs in air and were read-out using a Harshaw 3500 TLD reader. The TLDs were read-out using four read-out heating rates at 10, 7, 4 and 1 °C s{sup −1}. It was observed that lowering the heating rate could separate more glow peaks. The activation energy for peak 5 was found to be lower than that for peak 4. The peak maximum temperature and the integral value of the main peak decreased as the heating rate decreases.

  6. Measure of the attenuation curve of a beam of X-rays with TLD-100 dosimeters of LiF

    International Nuclear Information System (INIS)

    Bonzi, E. V.; Mainardi, R. T.; Germanier, A.; Delgado, V.

    2011-10-01

    The attenuation curve of a beam of X-rays represents the beam intensity in function of the attenuator thickness interposed between the source and the detector. To know with the major possible precision the attenuation curve is indispensable in procedures of spectral reconstruction. Their periodic measuring also offers valuable information on the correct operation of a tube of X-rays, diagnostic or therapy, when not have a specific detector for that activity. In this work was measured the attenuation curve of a tube of X-rays operated to 50 kV and 0.5 ma, using existent elements in any diagnostic or therapy laboratory with radiations. In the measures commercial aluminum foil was used, bent until 24 times and thermoluminescent dosimeters TLD 100 - LiF. Also, for comparison, was measured this attenuation curve with an ionization chamber brand Capintec model 192. Was determined by X-rays fluorescence the composition of the aluminium foil, since the present elements in the alloy can to affect the form of the attenuation curve. It is interesting to observe that these elements are in very low proportion (ppm) that they do not alter the attenuation capacity of the pure aluminium. Finally in a precision balance we weigh a big piece (30 cm x 100 cm) of aluminium foil and we obtained the thickness in g/c m2. It is possible to obtain attenuation curves of a beam of X-rays, with a high precision procedure and reproducibility. The use of TLD-100 dosimeters of LiF or similar makes that this activity was also quick and simple. (Author)

  7. Thermoluminescent response of dosemeters TLD-100 exposed to distinct baker protocols, irradiation and reading; Respuesta termoluminiscente de dosimetros TLD-100 sujetos a distintos protocolos de horneado, irradiacion y lectura

    Energy Technology Data Exchange (ETDEWEB)

    Estrada E, D

    2002-07-01

    The interest that motivated the realization of this work is the opposing discrepancy among the values of the efficiency thermoluminescent of heavy charged particles (PCP) regarding gamma radiation ({eta}{sub PCP}, {gamma}) reported in different works and gathered recently for Horowitz (Ho 01). The measures of relative thermoluminescent efficiency have importance in relation to the dosimetry associated to medical therapy with heavy charged particle. The measurement of {eta}{sub PCP}, {gamma} depends of multiple experimental factors. To understand this dependence it was quantified the effect of using different procedures experimental in the estimate of the relative thermoluminescent efficiency of dosemeters TLD-100 (LiF: Ti; Mg) for protons of 3 MeV regarding gamma rays of {sup 60}Co ({eta}{sub PCP}, {gamma}), varying the lot, the presentation, the one baked and the team reader. When was used the same global procedure values they were obtained for ({eta}{sub PCP}, {gamma}) inside the interval [0.30, 0.58] for the peak 5 and [0.35, 0.76] for the total thermoluminescent signal (Tl). At the use different equipment, baked and lot are obtained maximum differences of 30%, 12% and 6% respectively in the values of ({eta}{sub PCP}, {gamma}) for the peak 5, and 25%, 28% and 7% for the total Tl signal. The changes more significant of 36% and 44% for peak 5 and total signal respectively are obtained when changing the presentation of the dosemeter. As a complementary investigation it was studied the distribution of the Tl signal of each peak in the deconvolution of the curve of brightness with regard to the total signal in exposed dosemeters to high fluence of protons (1x10{sup 10} p/cm{sup 2}) varying the experimental protocol. It was found that the distribution of the Tl signal has a difference of the order of 5% when changing the used reading team. It was observed that the contribution of the peak 5 regarding the total signal are preserved when changing baked and that it

  8. Dosimetric evaluation of the response of the TLD-100 dosemeters in the IMRT technique by 'Step and Shoot'

    International Nuclear Information System (INIS)

    Vasquez, J.; Benavides, S.O.

    2005-01-01

    We show the results of the dosimetry response of LiF thermoluminescent crystals: TLD-100, where they were radiated in a linear accelerator Siemens Primus Hl using the Intensity Modulated Radiation Therapy (IMRT) by step and shoot technique. Previous to the crystals calibration and response evaluation, the acceptation procedures recommended by the TG-53 protocol for validation of the technique were carried out. The planning system utilized was the Theraplan Plus 3.8, using the algorithm of Pencil Kernel. The register and verification system was Lantis 5.2. The response curve of dose versus charge was obtained from the readings of the TLD in a Harshaw 3500. The crystals were radiated in a Bench- Marck phantom with doses previously determined by using ionization chambers for square radiation fields, in a beam with a 0.68 TPR20,10 corresponding to 6 MV of energy. We compare the response of these through of radiation of segmented fields in a Anthropomorphic phantom and the calculated doses by the planning system. The results obtained in the crystals response show deviations less than 5 % between the measured dose and the calculated dose in the zones of low gradient. It allows its implementation like routine control of quality by IMRT. (Author)

  9. Study of the influence of the time temperature profile on the minimum detectable dose of TLD-100

    International Nuclear Information System (INIS)

    Meireles, Leonardo S.; Lacerda, Marco Aurelio S.; Meira-Belo, Luiz C.; Ferreira, Hudson R.

    2013-01-01

    Monitoring of workers and workplaces is an integral part of any radiation protection programme (RPP). It is essential to demonstrate compliance with regulations that limit the allowable dose to the public from manmade sources and to enable the responsible of the installations to verify compliance with the legal dose limits to the workers and ALARA goals. Thermoluminescent dosemeters (TLDs) are generally employed to assess the environmental and personnel doses. To completely characterize a TLD dosimetry system is fundamental to determine the Lowest Dose that the system is capable of measuring. As the amount of the light emitted by TLD material is a function of the time temperature profile (TTP), in the present study, the influence of the TTP on the Detection Threshold (MDD) of the LiF:Mg,Ti (TLD-100) detectors was evaluated. Eighteen different TTPs were tested for two different annealing processes: (I) utilization of the TTP itself and; (II) a microprocessor controlled oven annealing procedure. Results showed that TTP choice can influence significantly in the MDD values. The worst results were generally found for TLDs annealed by the TTP itself. The lack of pattern or the unexpected behavior to the influence of some parameters of the TTP on the calculated MDDs must be carefully investigated. Greater variations on the TTP parameters must be undertaken. Special attention must be also done on the methodology of calculating the MDDs. (author)

  10. A Dosimetry of 106-Ru - 106- Rh Electron-Photon Field with LiF TLD-100 'Microcubes'

    International Nuclear Information System (INIS)

    Kovacevic, N.; Vrtar, M.; Vekic, B.; Knezevic, Z.

    2003-01-01

    Background and purpose: Ru-Rh eye applicators are used for the radiotherapy of eye malignancies such as melanomas. The producer (BEBIG GmbH) declares ±30% dose uncertainty in the applicator certificate. There is an obvious need to overcome this large imprecision. Our goal is to establish a method that is fast and reliable and which reduces dose uncertainty to below ±10%. Materials and methods: A pleksiglas phantom containing spherical calottes was constructed for this purpose. It allows measurements of surface homogeneity, absolute surface dose rates and depth doses in 2 mm steps, on and off the symmetry axis. Very small, 1x1x1 mm 3 thermoluminescent dosimeters (TLD) were chosen as dosimeters. They have to be calibrated adequately for Ru-Rh dosimetry. To do that, 6 0C o/electron field response ratio of TLDs was investigated and correction factors were established. Doses to the base of optic nerve were considered. Results: The 6 0C o/electron beam response ratio of TLDs is in agreement with measured and calculated results reported by other authors (for LiF TLD-100 of different dimensions). The measurements of surface dose rate homogeneity show deviations of up to 15% of the mean surface dose rate. However, surface inhomogeneities average out deeper in the phantom. Absolute surface dose rates were found lower than those declared by the producer by 6.2%, averaged over 8 applicators investigated. On and off axis depth doses are highly uniform over angle θ=40 degrees from symmetry axis, up to 6 mm in depth. Therefore, depth doses form spherical isodose surfaces within stated angle, spanning at least 1.47 steradians. Depth dose functions were interpolated to the measured data for practical routine use. Conclusions: The method developed here has overall combined uncertainty <±6%, and therefore reduces significantly uncertainty declared by the producer. Also, it proved to be stable on repeated measurements. (author)

  11. Dosimetric analysis using glasses TLD-100 Lif; Mg; TI for the optimization of the quality control programs in radio surgery stereo tactic

    International Nuclear Information System (INIS)

    Maldonado, J. C; Plazas, M. C.; Dussan, R.; Conrado, Z.; Pena, G.; Jimenez, E.; Hakim, F.; Bermudez, S.

    2001-01-01

    The conditions of Stereo Tactic Radio Surgery treatments are simulated by means of the use of thermo luminescent glasses TLD-100 LiF; Mg; Ti placed in mannequins, to demonstrate that the doses received by the patients, either in the fractioned or in the mono fractioned techniques, are over the 500cGy, making urgent the use of a reliable dosimetric method [es

  12. Production dosimeter LiF: Mg, Ti and comparison its responses with dosimeter LiF: Mg, Ti (TLD-100) in Harshaw company against of gamma rays

    OpenAIRE

    KH Mohammadi; R Sarraf Maamory; R Mohammadi; A Mosavi Zarandi

    2010-01-01

    Thermoluminescence dosimeters are small tablets used with 3. 2*3. 2*0. 9mm^3 for measurement of received dose from radioactive various beams. The most common dosimeter is TLD-100 which is lithium-fluoride family and this dosimeter contain magnesium impurities. In this study, first lithium-flouride powder was mixed with titanium and controlled atmosphere samples were heated. After measuring of samples density and hardness, their glow curves were drawn and microscopic pictures of producted samp...

  13. Proton/gamma relative thermoluminescence efficiencies of LiF:Mg,Cu,P+PTFE prepared at ININ and TLD-100H

    Energy Technology Data Exchange (ETDEWEB)

    Avila, O.; Gonzalez, P.; Murillo, G. [Departamento de Fisica, ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico)

    2009-10-15

    Properties of LiF:Mg,Cu,P+PTFE dosemeters developed at ININ have been investigated in order to evaluate their performance compared to those of equivalent commercial dosemeters. In this work both LiF:Mg,Cu,P+PTFE and TLD-100H pellets were exposed to low fluence 3 MeV protons and to low dose gamma radiation to evaluate experimental proton/gamma efficiencies. Gamma irradiation was performed using the Vic krad irradiator at ININ at varying doses between 25 and 500 mGy. For proton irradiation the Tandem Van de Graaff accelerator at ININ was used. Dosemeters were placed on a holder inside a scattering chamber where protons impinge on a gold target and scatter in all directions. The holder allows for several angular positions so that dosemeters receive proton fluence between 10{sup 6} and 10{sup 1}0 p/cm{sup 2}. Experimental efficiency values found for LiF:Mg,Cu,P+PTFE and TLD-100H were 0.18 +- 03 and 0.23 +- 0.03, respectively. These results allow to confirm the reliability of the dosemeters developed at ININ. (Author)

  14. A comparative evaluation of luminescence detectors: RPL-GD-301, TLD-100 and OSL-AL2O3:C, using Monte Carlo simulations

    Science.gov (United States)

    Benali, A.-H.; Medkour Ishak-Boushaki, G.; Nourreddine, A.-M.; Allab, M.; Papadimitroulas, P.

    2017-07-01

    The luminescent dosimeters are widely used in clinical practice, for the monitoring of patient dose in external radiation therapy. Three of the most common dosimeter categories are the thermoluminescence (TLDs), the radiophotoluminescence (RPLs) and the optically stimulated luminescence (OSLs), with similar physical processes on their properties. The aim of the present study is to compare and evaluate the dosimetric properties of three specific luminescent detectors namely: a) RPL glass dosimeter, commercially known as GD-301, b) lithium fluoride TLD-100 (LiF:Mg,Ti) and c) carbon-doped aluminum oxide (Al2O3:C). For this purpose, Monte Carlo simulations were applied, using the MCNP5 code to estimate the responses of these dosimeters in terms of absorbed dose, output factor, the angular and energy dependence. In the present study, we found that the differences between the output factors were less than ± 4.2% for all detector materials RPLGD, TLD and OSLD. The variations in sensitivity for angles up to ± 80 degrees from the central axis of the beam were approximately 0.5%, 0.8% and 1.5% for the TLD-100, GD-301 and Al2O3:C, respectively. The energy dependence of the RPL and OSL dosimeters are stated as less than a 2.2%, and within 5.8% for TLD.

  15. Production dosimeter LiF: Mg, Ti and comparison its responses with dosimeter LiF: Mg, Ti (TLD-100 in Harshaw company against of gamma rays

    Directory of Open Access Journals (Sweden)

    KH Mohammadi

    2010-03-01

    Full Text Available Thermoluminescence dosimeters are small tablets used with 3. 2*3. 2*0. 9mm^3 for measurement of received dose from radioactive various beams. The most common dosimeter is TLD-100 which is lithium-fluoride family and this dosimeter contain magnesium impurities. In this study, first lithium-flouride powder was mixed with titanium and controlled atmosphere samples were heated. After measuring of samples density and hardness, their glow curves were drawn and microscopic pictures of producted samples were provided. Of course, the reader should know that the best press pressure, the best range of temperature heating and the best range of samples heating were determined in 6-8 (ton/cm2, 775-800 ° C and 15-20 h, respectively [1]. Then, the response of producted TLD-100 under radiation of gamma sources, 60Co, was measured in 500 mSv rate and obtained values were compared with obtained values by Harshaw producted samples. Dosimetry characteristics of producted samples was evaluated according to ASTM E 668-00, IEC-ISO 1066 standards. The results of comparisions indicate good agreements between producted sample and Harshaw sample.

  16. Proton/gamma relative thermoluminescence efficiencies of LiF:Mg,Cu,P+PTFE prepared at ININ and TLD-100H

    International Nuclear Information System (INIS)

    Avila, O.; Gonzalez, P.; Murillo, G.

    2009-10-01

    Properties of LiF:Mg,Cu,P+PTFE dosemeters developed at ININ have been investigated in order to evaluate their performance compared to those of equivalent commercial dosemeters. In this work both LiF:Mg,Cu,P+PTFE and TLD-100H pellets were exposed to low fluence 3 MeV protons and to low dose gamma radiation to evaluate experimental proton/gamma efficiencies. Gamma irradiation was performed using the Vic krad irradiator at ININ at varying doses between 25 and 500 mGy. For proton irradiation the Tandem Van de Graaff accelerator at ININ was used. Dosemeters were placed on a holder inside a scattering chamber where protons impinge on a gold target and scatter in all directions. The holder allows for several angular positions so that dosemeters receive proton fluence between 10 6 and 10 1 0 p/cm 2 . Experimental efficiency values found for LiF:Mg,Cu,P+PTFE and TLD-100H were 0.18 +- 03 and 0.23 +- 0.03, respectively. These results allow to confirm the reliability of the dosemeters developed at ININ. (Author)

  17. Experimental determination of relative light conversion factors of TLD-100 for protons with energies from 2.0 to 9.0 MeV

    International Nuclear Information System (INIS)

    Schmidt, P.; Fellinger, J.; Huebner, K.; Henniger, J.

    1985-01-01

    Relative light conversion factors (RLCF) for heavy charged particles (protons, deuterons, recoils) are needed for the calculation of the neutron sensitivity of thermoluminescent (TL) detectors. Such light conversion factors can be determined experimentally. A method is represented for the experimental determination of RLCF. The described experimental facility gives the possibility of irradiation of different luminophor samples with heavy charged particles and flux determination and particle spectrometry at the same time. For the determination of RLCF the doses are needed which are applicated at the irradiation with heavy charged particles and gamma radiation, respectively, and the according detector readings at the TL evaluation. The problems arising at the dose determination are discussed. With this experimental facility the RLCF for TLD-100 for protons were determined. The relative light conversion factors determined according to the light sum method as well as the peak height method are summarizinhly represented and discussed. Furthermore a comparison of the glow curves is made after gamma and proton irradiation

  18. Experimental determination of relative light conversion factors of TLD-100 for protons with energies from 2.0 to 9.0 MeV

    International Nuclear Information System (INIS)

    Schmidt, P.; Fellinger, J.; Henniger, J.; Huebner, K.

    1988-01-01

    The efficiency of thermoluminescent (TL) detectors to heavy charged particles is described by the so-called light conversion factor η. Relative light conversion factors for protons, alphas and heavier recoils are needed for the calculation of the neutron sensitivity of TL detectors. Such light conversion factors can be determined experimentally. In this paper a method is presented for the experimental determination of relative light conversion factors. Using the experimental arrangement described, relative light conversion factors for LiF material (TLD-100) for protons were determined. In LiF the relative main peak (peak V) efficiency is always lower than 1. It increases with increasing proton energy whereas the relative efficiency of the high temperature peak (peak VI) shows an opposite dependence on the proton energy. Relative light conversion factors for peak VI clearly exceed 1. (orig.)

  19. Application of the Cavity theory in the calibration of the powder TLD-100 for energies of 60 Co, 137 Cs, 192 Ir and RX 50, 250 k Vp

    International Nuclear Information System (INIS)

    Loaiza C, S.P.; Alvarez R, J.T.

    2006-01-01

    A powder lot TLD-100 (LiF:Mg,Ti) in absorbed dose terms in water D w for the following radiation sources: 60 Co, 137 Cs and RX 50 and 250 k Vp is calibrated; to continuation is made a lineal interpolation of the TLD response in function of the effective energy of the sources to calibrate a source of 192 Ir. The calibration of those fields in D w are carried out with aid of the Bragg-Gray cavity theory, the one which finds implicit in the following protocols: IAEA-TRS 398 for the 60 Co and the AAPM TG61 for X Rays of 50 and 250 k Vp. Additionally the AAPM protocol TG43 to determine the D w in function of the kerma intensity S k in the case of the 137 Cs is used. The calibration curves for the response of the TLD-100 R TLD vs D w , corresponding to each one of the sources already mentioned are constructed. The R TLD vs D w by least heavy square by means of a second order polynomial that corrects the supralineality of the response is adjusted. The curves are validated by lack of LOF adjustment and by the Anderson Darling normality test. Later the factors of sensitivity (F s ) for the sources of 192 Ir: Micro Selectron and Vari Source are interpolated, used respectively in the A and B hospitals for treatments of brachytherapy of high dose rate (HDR), the expanded uncertainties associated to the D w and F s are also determined. Finally, an acrylic phantom and a couple of capsules are already sent to the hospitals mentioned, to verify a nominal D w of 2 Gy, in a case an underestimate in 5.5% in the imparted D w and in other an overestimation in a range of -1.5 to -8.0% was obtained. The obtained results in this work establish the bases for the development of a national dosimetric quality control program for brachytherapy of HDR with sources of 192 Ir. (Author)

  20. Measurement of the dose to the family members taking care of thyroid cancer patients undergoing I-131 therapy in nuclear medicine using TLD-100

    International Nuclear Information System (INIS)

    Zehtabian, M.; Dehghan, N.; Danaei Ghazanfarkhani, M.; Haghighatafshar, M.; Sina, S.

    2017-01-01

    The family members or friends of the patients undergoing treatment using radioiodine in nuclear medicine are inevitably exposed to ionization radiation. The purpose of this study is measurement of the dose received by the people taking care of the thyroid cancer patients treated by 131 I. For this purpose, the dose amounts received by 29 people accompanying patients were measured using thermoluminescence dosimeters. A badge containing three TLD-100 chips was given to each caregiver. The people were asked to wear the badges for 24 days, when they are taking care of the patients. Finally the dose to each person was estimated by averaging the readings of the three TLDs. The measured dose amounts to the people were compared with the recommendations of international commissions. According to the results obtained in this study, the amounts of dose received by the caregivers were between 0.03 and 0.38 mSv, with the average of 0.12 mSv. By comparison of the results of this study with the recommendations of International Commission on Radiological Protection (ICRP), it can be observed that the dose to family members of the patients is less than the dose constraints. However, it is recommended that the caregivers be aware of the radiation protection principles in order to reduce their dose. (authors)

  1. Comparison of the calculated absorbed dose using the Cadplan™ treatment planning software and Tld-100 measurements in an Alderson-Rando phantom for a bronchogenic treatment

    Energy Technology Data Exchange (ETDEWEB)

    Gutiérrez Castillo, J. G., E-mail: jggc59@hotmail.com [Departamento de Física, Hospital de Oncología, IMSS, CMN Siglo XXI, Cuauhtémoc 330 Col. Doctores (Mexico); Álvarez Romero, J. T., E-mail: trinidad.alvarez@inin.gob.mx, E-mail: fisarmandotorres@gmail.com, E-mail: victor.tovar@inin.gob.mx; Calderón, A. Torres, E-mail: trinidad.alvarez@inin.gob.mx, E-mail: fisarmandotorres@gmail.com, E-mail: victor.tovar@inin.gob.mx; M, V. Tovar, E-mail: trinidad.alvarez@inin.gob.mx, E-mail: fisarmandotorres@gmail.com, E-mail: victor.tovar@inin.gob.mx [SSDL, Departamento de Metrología ININ, Salazar, Estado de México 15245 (Mexico)

    2014-11-07

    To verify the accuracy of the absorbed doses D calculated by a TPS Cadplan for a bronchogenic treatment (in an Alderson-Rando phantom) are chosen ten points with the following D's and localizations. Point 1, posterior position on the left edge with 136.4 Gy. Points: 2, 3 and 4 in the left lung with 104.9, 104.3 and 105.8 Gy, respectively; points 5 and 6 at the mediastinum with 192.4 and 173.5 Gy; points 7, 8 and 9 in the right lung with 105.8, 104.2 and 104.7 Gy, and 10 at posterior position on right edge with 143.7 Gy. IAEA type capsules with TLD 100 powder are placed, planned and irradiated. The evaluation of the absorbed dose is carried out a curve of calibration for the LiF response (nC) {sup vs} {sup DW}, to several cavity theories. The traceability for the DW is obtained with a secondary standard calibrated at the NRC (Canada). The dosimetric properties for the materials considered are determined from the Hounsfield numbers reported by the TPS. The stopping power ratios are calculated for nominal spectrum to 6 MV photons. The percent variations among the planned and determined D in all the cases they are < ± 3%.

  2. Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters.

    Directory of Open Access Journals (Sweden)

    Guerda Massillon-J L

    Full Text Available This work investigated the suitability of passive dosimeters for reference dosimetry in small fields with acceptable accuracy. Absorbed dose to water rate was determined in nine small radiation fields with diameters between 4 and 35 mm in a Leksell Gamma Knife (LGK and a modified linear accelerator (linac for stereotactic radiosurgery treatments. Measurements were made using Gafchromic film (MD-V2-55, alanine and thermoluminescent (TLD-100 dosimeters and compared with conventional dosimetry systems. Detectors were calibrated in terms of absorbed dose to water in (60Co gamma-ray and 6 MV x-ray reference (10×10 cm(2 fields using an ionization chamber calibrated at a standards laboratory. Absorbed dose to water rate computed with MD-V2-55 was higher than that obtained with the others dosimeters, possibly due to a smaller volume averaging effect. Ratio between the dose-rates determined with each dosimeter and those obtained with the film was evaluated for both treatment modalities. For the LGK, the ratio decreased as the dosimeter size increased and remained constant for collimator diameters larger than 8 mm. The same behaviour was observed for the linac and the ratio increased with field size, independent of the dosimeter used. These behaviours could be explained as an averaging volume effect due to dose gradient and lack of electronic equilibrium. Evaluation of the output factors for the LGK collimators indicated that, even when agreement was observed between Monte Carlo simulation and measurements with different dosimeters, this does not warrant that the absorbed dose to water rate in the field was properly known and thus, investigation of the reference dosimetry should be an important issue. These results indicated that alanine dosimeter provides a high degree of accuracy but cannot be used in fields smaller than 20 mm diameter. Gafchromic film can be considered as a suitable methodology for reference dosimetry. TLD dosimeters are not

  3. Personal dosimetry TLD 100 in orthopedic surgeons exposed to ionizing radiation in Bogota - Colombia; Dosimetria personal TLD 110 en medicos ortopedistas expuestos a radiacion ionizante en Bogota - Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Sierra C, B. Y.; Jimenez, Y. [Universidad Nacional de Colombia, Departamento de Fisica, Grupo de Fisica Medica, Carrera 45 No. 26-85, Bogota (Colombia); Plazas, M. C. [Hospital Universitario Fundacion Santa Fe de Bogota, Instituto de Oncologia Carlos Ardila Lulle, Calle 119, No. 7-90, 220246 Bogota (Colombia); Eslava S, J. [Universidad Nacional de Colombia, Instituto de Investigaciones Clinicas, Grupo Equidad en Salud, Carrera 45 No. 26-85, Bogota (Colombia); Groot R, H., E-mail: brigith.sierra@gmail.com [Universidad de los Andes, Laboratorio de Genetica Humana, Carrera 1 No. 18A -12, Bogota (Colombia)

    2014-08-15

    Orthopedic surgeons should be considered as professionals occupationally exposed to ionizing radiation, for using C arc (fluoroscope) an equipment of X type radiation emission, during surgical procedures for imaging generation. Some health institutes, use of C arc under uncontrolled circumstances, such a lack of dosimetry control, incomplete or absence of personnel protective elements and protective measures, which in turn, lead to a high exposition to the personnel. Materials and methods. Study of double match cohort by age and gender, was conducted, in four health institutions of second and third level of attention in Bogota city. Personal dosimetry measurements with TLD-100 dosimetry crystals in both cohorts and environmental dosimetry in each of operation rooms used for orthopedic procedures, were carry out during six months of follow up. Dosimetry crystals were read in a Harshaw 4500 - Bicron equipment, in the Medical Physics Laboratory of National University of Colombia. Results. Dosimetry measurements are compatibles with those of occupationally exposed personnel 3.44 mSv/6 m CI 95% (1.66-3.99), even does not overpass ICRP recommendations, are higher as were expect at the beginning of the study. The median of effective accumulative dose in thorax is 3,4 mSv CI 95% (1,66-3,99), higher in comparison with neck value 2,7 mSv CI 95% (1,73-3,80) and hand dosimetry 1,42 mSv CI 95% (0,96-2,34). Conclusions: Orthopedic surgeons should be considered occupational exposed to ionizing radiation, who has to accomplish to the radiological protection measures, dosimetric follow up and maintenance of the used X ray equipment. It was confirm throughout this study that dosimetry shows higher levels as expected at the beginning of the study, compatible with occupationally exposed personnel. (Author)

  4. Dosimetric evaluation of the response of the TLD-100 dosemeters in the IMRT technique by 'Step and Shoot'; Evaluacion dosimetrica de la respuesta de los dosimetros TLD-100 en la tecnica de IMRT por 'Step and Shoot'

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, J. [Fundacion Clinica Valle del Lili, A.A. 020338, Cali (Colombia); Benavides, S.O. [Depto. de Fisica, Universidad del Valle, A.A. 25360, Cali (Colombia)

    2005-07-01

    We show the results of the dosimetry response of LiF thermoluminescent crystals: TLD-100, where they were radiated in a linear accelerator Siemens Primus Hl using the Intensity Modulated Radiation Therapy (IMRT) by step and shoot technique. Previous to the crystals calibration and response evaluation, the acceptation procedures recommended by the TG-53 protocol for validation of the technique were carried out. The planning system utilized was the Theraplan Plus 3.8, using the algorithm of Pencil Kernel. The register and verification system was Lantis 5.2. The response curve of dose versus charge was obtained from the readings of the TLD in a Harshaw 3500. The crystals were radiated in a Bench- Marck phantom with doses previously determined by using ionization chambers for square radiation fields, in a beam with a 0.68 TPR20,10 corresponding to 6 MV of energy. We compare the response of these through of radiation of segmented fields in a Anthropomorphic phantom and the calculated doses by the planning system. The results obtained in the crystals response show deviations less than 5 % between the measured dose and the calculated dose in the zones of low gradient. It allows its implementation like routine control of quality by IMRT. (Author)

  5. Characterization of TLD-100 in powders for dosimetric quality control of 192 Ir sources used in brachytherapy of high dose rate

    International Nuclear Information System (INIS)

    Loaiza C, S.P.

    2007-01-01

    The Secondary Standard Dosimetric at the National Institute of Nuclear Research (ININ) calibrated a lot of powdered TLD-100 (LiF:Mg,Ti) in terms of absorbed dose to water D w for the energy of: 60 Co, 137C s, X rays of 250 and 50 kVp. Later on, it is carried out an interpolation of the calibration for the energy of the 192 Ir. This calibration is part of a dosimetric quality control program, to solve the problems of traceability for the measurements carried out by the users of 192 Ir sources employed in the treatments of High Dose Rate Brachytherapy (HDR) at the Mexican Republic. The calibrations of the radiation beams are made with the following protocols: IAEA TRS-398 for the 60 Co for D w , using a secondary standard ionization chamber PTW N30013 calibrated in D w by the National Research Council (NRC, Canada). AAPM TG-43 for D w in terms of the strength kerma Sk, calibrating this last one quantity for the 137 Cs radioactive source, with a well chamber HDR 1000 PLUS traceable to the University of Wisconsin (US). AAPM TG-61 for X ray of 250 and 50 kVp for D w start to Ka using field standard a Farmer chamber PTW 30001 traceable to K for the Central Laboratory of Electric Industries (CLEI, France). The calibration curves (CC) they built for the response of the powder TLD: R TLD vs D w : For the energy of 60 Co, 137 Cs, X rays of 250 and 50 kVp. Fitting them with the least square method weighed by means of a polynomial of second grade that corrects the supra linearity of the response. iii. Each one of the curves was validated with a test by lack of fitting and for the Anderson Darling normality test, using the software MINITAB in both cases. iv. The sensibility factor (F s ) for each energy corresponds to the slope of the CC, v. The F s for the two 192 Ir sources used are interpolated: one for a Micro Selectron source and the other one a Vari Source source. Finally, a couple of capsules were sent to two hospitals that have the HDR Brachytherapy with sources of 192

  6. Experimental calibration and determination of the relative response for Lif: Mg, Ti(TLD-100) dosemeters at 60Co gamma and 60 kVp X-ray energies

    International Nuclear Information System (INIS)

    Marco, M.L.; Gonzalez, L.; Delgado, V.; Vano, E.; Moran, P.

    1985-01-01

    The thermoluminescence efficiency of LiF: Mg, Ti (TLD-100) dosemeters has been determined for photon beams from 60 Co gamma rays and 60 kVp X-rays. It has been proven that light yield varies as a function of the photon energy. An experiment was performed using an X-ray beam whose spectrum has been determined by an X-ray fluorescence method. This enabled a direct calculation of the absorbed doses in the T1 material for the different operation conditions. These values and the experimental ones from measuring T1 intensities have been used to obtain the efficiency for energy X-ray spectrum. From the above values, the dosemeter T1 response, relative to 60 Co, has been evaluated. (author)

  7. Estimation of DNA DSB radiation damage using a solid state nanodosimeters based on glow peak 5a in LiF:Mg,Ti (TLD-100)

    International Nuclear Information System (INIS)

    Oster, L.; Haddad, J.; Horowitz, Y.S.; Biderman, S.

    2002-01-01

    We demonstrate the viability of the concept of using existing molecular nano structures in TL solid-state nanodosimeters. The concept is based on mimicking radiobiology (specifically the ionization density dependence of double strand breaks in DNA) by using the similar ionization density dependence of simultaneous electron-hole capture in spatially correlated TC/LC pairs in the thermoluminescence of LiF:Mg, Ti. This simultaneous electron-hole capture has been shown to lead to ionization density dependence in the relative intensity of peak 5a to peak 5 similar to the ratio of DSBs to SSBs for low energy He ions. (authors)

  8. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative quantities ICRU, for external fields of beta radiation. Part II. I study of the angular response of personal dosemeters TLD-100 in secondary patron fields of beta radiation (90Sr / 90Y)

    International Nuclear Information System (INIS)

    Alvarez R, J.T.

    1994-01-01

    The objective of this work is to carry out one of the possible ones test type for personal dosemeters TLD, under the recomendations of the ICRU 39, ICRU 43 and the draft of the norm ISO 6980,(1992), with the purpose of verifying the capacity of these detectors to carry out the operative unit: H' (0.07;α). Since H' (O. 07;α) this defined one in an expanded field, one of these tests type consist on determining the angular response of these detectors. 20 personal dosemeters TLD-100 was used, (card marks: Harshaw, Model: G-1, with two glasses of TLD-100 absorbed in teflon; the portadosemeters has two windows, a free one and another with a filter of Pb of 171.0 mg cm -2 ); these dosemeters they were previously selected, [to see, S tudy of the Homogeneity of the response of Personal Dosemeters (Cards G-l, TLD-100) in Radiation of Countrysides of 60 Co , J.T. Alvarez R. Technician Report GSR/IT/0001/94].The irradiations to effectued in secondary countryside of radiation beta of 90 Sr/ 90 Y. The study was undertaken by means of an experimental design of blocks random that contemplate the following variables: intensity of the radiation source, (1850 MBq and 74 MBq); position of irradiation, (four positions); incidence of angle of the radiation (0, 15, 30, 45, 60 and 75 grades) and the absorbed dose in air, (0.005, 0.010, 0.020, 0.050 and 0.100 Gy). Then null hypothesis it was to suppose that there was not difference among the stockings of each treatment, to used the statistical of Duncan to carry out tests of stockings at a level of significance of 5%.These tests of stockings throw the following results in those variables of the experimental design: The irradiations carried out so much with the source pattern secondary of 90 Sr/ 90 Y of 1850 MBq and of 74 MBq, they are equivalent reason why they can be used indistinctly. The responses of each one of the glasses of the card are strongly anisotropic for each glass; four positions of irradiation is used: glass 1 (window of

  9. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative magnitudes ICRU, for external fields of beta radiation. Part I. Study of the homogeneity of the response personal dosemeters leaves (cards G-1, TLD-100), in radiation fields of Co60

    International Nuclear Information System (INIS)

    Alvarez R, J.T.

    1994-01-01

    A sample of 40 composed personal dosemeters by cards model: G-l, (each card is made up of two TLD-100 crystals encapsulated in teflon), Harshaw trademark; those personal dosemeters present a free window and another with a filter of A1 of 171.7 mg cm -2 of mass thickness.The objective of the work is to select of this sample of 40 personal dosemeters a population with the same stocking and standard deviation. The technique used is that of comparison of stockings, (ANOVA; Variance Analysis, when samples of the same one were had size; and/or GLM, Widespread Lineal Models, when the samples were of different size), by means of the use of those Duncan statistics, SNK, Tukey, Gabriel; the results are validated proving the kindness of adjustment of the experimental data to a Normal distribution by means of the Shapiro-Wilks statistics.The experimental design used consists on a test of two vias: a via is the variable card with two levels, (crystal 1 and 2), the other via is the variable irradiation position with four levels, (LS=left superior, SR= right superior, LI= left Inferior, IR = right inferior). The irradiations carried out in blocks of four personal dosemeters in a gamma radiation beam range of Cobalt 60; carrying out three repetitions of the design. With object of proving the homogeneity of the filter of A1 in those personal dosemeters the experimental design was executed for those cards without personal dosemeters.They were also carried out tests of stockings to the readings of bottom and sensibility of the reader equipment, (Harshaw, model marks 2271), certain that doesn t exist differences for sequence of reading, but if in the stockings of the sensibility, (they were 4 different populations). The responses of the dosemeters were corrected subtracting him the reading correspondence of bottom and by sensibility of the reader equipment before subjecting them to the tests of stockings mentioned. Of the results of the tests of stockings for the cards with and

  10. Métodos experimentales de dosimetría postal para el control de calidad en radioterapia basados en LiF:Mg, Ti (TLD-100) y LiF:Mg, Cu P (GR-200) : aplicación de métodos numéricos al análisis de las curvas de termoluminiscencia

    OpenAIRE

    Muñiz Gutiérrez, José Luis

    1999-01-01

    Las aplicaciones médicas de las radiaciones están sin duda entre las que generan beneficios mayores y más directos en la calidad de vida de la población, con sus métodos diagnósticos y terapéuticos. No obstante, su empleo en actividades médicas obviamente no está exento de riesgos y precisamente es en algunas de tales aplicaciones donde el margen entre el riesgo indebido y el beneficio esperado es menor y más dependiente de la calidad del procedimiento utilizado. Por ejemplo en radioterapia, ...

  11. PFI-ZEKE (Pulsed Field Ionization-Zero Electron Kinetic Energy) para el estudio de iones

    Science.gov (United States)

    Castaño, F.; Fernández, J. A.; Basterretxea, A. Longarte. F.; Sánchez Rayo, M. N.; Martínez, R.

    Entre las áreas hacia donde ha evolucionado la Química en los últimos años están los estudios de sistemas con especies reactivas de alta energía y los dominados por fuerzas intermoleculares débiles, con energías de unas pocas kcal/mol. En efecto, el estudio de las propiedades de los iones, comenzando por su relación con la molécula neutra de la que procede, la energía de ionización, los estados vibracionales y rotacionales, energías de enlace de Van der Waals entre el ión y una amplia variedad de otras moléculas, sus confórmeros o isómeros y sus reacciones o semi-reacciones químicas están en la raíz de la necesidad de la espectroscopía conocida como PFI-ZEKE, Pulsed Field Ionization-Zero Electron Kinetic Energy. Entre las aplicaciones que requieren estos conocimientos se encuentran la generación de plasmas para la fabricación de semiconductores, memorias magnéticas, etc, así como los sistemas astrofísicos, la ionosfera terrestre, etc. La espectroscopía ZEKE es una evolución de las de fluorescencia inducida por láser, LIF, ionización multifotónica acrecentada por resonancia, REMPI, con uno y dos colores y acoplada a un sistema de tiempo de vuelo, REMPI-TOF-MS, y las espectroscopías de doble resonancia IR-UV y UV-UV. Sus espectros y la ayuda de cálculos ab inicio permite determinar las energías de enlace de complejos de van der Waals en estados fundamental y excitados, identificar confórmeros e isómeros, obtener energías de ionización experimentales aproximadas (100 cm-1) y otras variables de interés. Al igual que con LIF, REMPI y dobles resonancias, es posible utilizar muestras gaseosas, pero los espectros están muy saturados de bandas y su interpretación es difícil o imposible. Se evitan estas dificultades estudiando las moléculas o complejos en expansiones supersónicas, donde la T de los grados de libertad solo alcanzan unos pocos K. Para realizar experimentos de ZEKE hay que utilizar una propiedad recientemente

  12. Nanomateriales para baterías de ion litio e ion sodio basados en diseños arquitecturados

    OpenAIRE

    López Luna, Mª del Carmen

    2014-01-01

    La energía es un bien fundamental para el desarrollo económico y social de cualquier país. Disponer de ella en las cantidades y tiempos requeridos, es determinante para garantizar el desarrollo de la economía. No obstante, el continuo crecimiento de la demanda energética está teniendo graves consecuencias para el medioambiente como el cambio climático, además de que se prevé el agotamiento de las fuentes de extracción de energía no renovables en las próximas décadas. El abastecimiento de e...

  13. Mercado para produtos reciclados à base de PET/HDPE/Ionômero

    Directory of Open Access Journals (Sweden)

    Pacheco Elen B.

    1999-01-01

    Full Text Available A expansão do mercado de poli(tereftalato de etileno (PET, considerada um fenômeno mundial, está acontecendo no Brasil. Hoje, o principal mercado para o PET é o de bebidas carbonatadas. O uso de PET em lugar do vidro vem trazendo inúmeras vantagens, incluindo menor peso, maior resistência ao impacto e menores custos de transporte. Foram estudados possíveis mercados para a mistura PET/HDPE, na proporção de 75/25, acrescida de uma pequena quantidade de compatibilizante. Os resultados do estudo indicam que possíveis mercados para o mistura poderá incluir o de embalagens para usos especiais e partes de automóvel.

  14. Pulse generator for bias materials in the plasma immerse ion implantation process; Generador de pulsos para polarizar materiales en el proceso de implantacion de iones inmersos en plasma

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Callegas, Regulo; Valencia Alvarado, Raul; Munoz Castro, Arturo Eduardo; Godoy Cabrera, Oscar Gerardo [Instituto Nacional de Investigaciones Nucleares, Mexico D.F. (Mexico); Moreno Saavedra, Hilda; Gonzalez Colin, Mireya; Mariano Escamilla, Hector Fernando [Instituto Tecnologico de Toluca, Estado de Mexico (Mexico)

    2003-10-15

    The 0-10 kV pulse generator has been designed, with 100 {mu}s duration and 1-100 Hz frequencies ranges. The use of the pulse generator is in the plasma immersed ion implantation technique (P III). The process was realized in 304 austenitic stainless steel, the results were analyzed by: SEM, X-rays diffraction and hardness Vickers. The hardness was increased due to the efficiency of the pulse generator and P III process, the results obtained showed that the nitrogen inside the stainless steel was implanted and besides some nitrides was formed and therefore the hardness was increased. Also, the more adequate work pressure was determined to carry out the P III process. [Spanish] Se presenta el diseno de un generador de pulsos de alto voltaje con amplitudes controladas de hasta 10 kV, la duracion maxima de los pulsos es del orden de los 100 {mu}s y frecuencia de repeticion en el intervalo de 1-100 Hz. La aplicacion de este generador de pulsos es para el proceso de implantacion de iones en materiales inmersos en plasmas (PIII). Los analisis hechos a los aceros austeniticos cedula 304 mediante microscopia electronica de barrido, difraccion de rayos X y dureza Vickers, muestran la eficiencia obtenida con el generador de pulsos en el proceso PIII, debido a que en el acero inoxidable se presenta un incremento en el nitrogeno y conformacion de algunos nitruros, lo cual da lugar al incremento de la dureza. Asimismo, se determino la presion de trabajo mas adecuada para llevar a cabo el proceso PIII.

  15. Para-Conjugated Dicarboxylates with Extended Aromatic Skeletons as the Highly Advanced Organic Anodes for K-Ion Battery.

    Science.gov (United States)

    Li, Chao; Deng, Qijiu; Tan, Haochen; Wang, Chuan; Fan, Cong; Pei, Jingfang; Cao, Bei; Wang, Zhihong; Li, Jingze

    2017-08-23

    A new family of the para-conjugated dicarboxylates embedding in biphenyl skeletons was exploited as the highly advanced organic anodes for K-ion battery. Two members of this family, namely potassium 1,1'-biphenyl-4,4'-dicarboxylate (K 2 BPDC) and potassium 4,4'-E-stilbenedicarboxylate (K 2 SBDC), were selectively studied and their detailed redox behaviors in K-ion battery were also clearly unveiled. Both K 2 BPDC and K 2 SBDC could exhibit very clear and highly reversible two-electron redox mechanism in K-ion battery, as well as higher potassiation potentials (above 0.3 V vs K + /K) when compared to the inorganic anodes of carbon materials recently reported. Meanwhile, the satisfactory specific and rate capacities could be realized for K 2 BPDC and K 2 SBDC. For example, the K 2 BPDC anode could realize the stable rate capacities of 165/143/135/99 mAh g -1 under the high current densities of 100/200/500/1000 mA g -1 , respectively, after its electronic conductivity was improved by mixing a very small amount of graphene. More impressively, the average specific capacities of ∼75 mAh g -1 could be maintained for the K 2 BPDC anode for 3000 cycles under the high current density of 1 A g -1 .

  16. Application of NIR - CRDS for state selective study of recombination of para and ortho H3+ ions with electrons in low temperature plasma

    Science.gov (United States)

    Varju, J.; Roučka, Š.; Kotrík, T.; Plašil, R.; Glosík, J.

    2010-05-01

    We present a study of H3+ recombination performed at 77 K on the two lowest rotational levels of this ion, which belong to its two different nuclear spin states of the studied ion. A near infrared cavity ring-down spectrometer (~1381 nm, CRDS arrangement) has been used to obtain the time evolution of concentration of both states. From the overall ion density decay during the afterglow we obtained the binary recombination rate coefficient αbin (77 K) = 1.2×10-7 cm3s-1. We have also observed ternary helium assisted recombination of both para and ortho H3+. The process is very slow (at 77 K) and the obtained ternary recombination rate coefficient is in contradiction with the theoretical prediction. It is the first time that the binary and ternary H3+ recombination rate coefficient was measured at a known population of para and ortho H3+ ions in decaying plasma.

  17. Application of NIR - CRDS for state selective study of recombination of para and ortho H3+ ions with electrons in low temperature plasma

    International Nuclear Information System (INIS)

    Varju, J; Roucka, S; KotrIk, T; Plasil, R; Glosik, J

    2010-01-01

    We present a study of H 3 + recombination performed at 77 K on the two lowest rotational levels of this ion, which belong to its two different nuclear spin states of the studied ion. A near infrared cavity ring-down spectrometer (∼1381 nm, CRDS arrangement) has been used to obtain the time evolution of concentration of both states. From the overall ion density decay during the afterglow we obtained the binary recombination rate coefficient α bin (77 K) = 1.2x10 -7 cm 3 s -1 . We have also observed ternary helium assisted recombination of both para and ortho H 3 + . The process is very slow (at 77 K) and the obtained ternary recombination rate coefficient is in contradiction with the theoretical prediction. It is the first time that the binary and ternary H 3 + recombination rate coefficient was measured at a known population of para and ortho H 3 + ions in decaying plasma.

  18. ions

    African Journals Online (AJOL)

    (MP2 B2). In order to draw the final conclusion about the content of the isomers of pentaatomic ions in saturated vapor over cesium chloride, we have taken into account the entropy factor. We considered the isomerization reactions which are given below: Cs3Cl2. + (V-shaped) = Cs3Cl2. + (cyclic or bipyramidal). (1). Cs2Cl3.

  19. Portable test bench for the studies concerning ion sources and ion beam extraction and focusing systems; Banco de pruebas portatil para el estudio de fuentes de iones y de la extraccion y enfoque del haz de iones

    Energy Technology Data Exchange (ETDEWEB)

    Cordero Lopez, F.

    1961-07-01

    A portable test bench is described, which was designed to check ion sources, ion beam extraction and focusing systems before its use in a 600 KeV Cockcroft-Walton accelerator. The vacuum possibilities of the system are specially analyzed in connection with its particular use. The whole can be considered as a portable accelerator of low energy (50 keV). (Author)

  20. Spectroscopy of prospective interstellar ions and radicals isolated in para-hydrogen matrices.

    Science.gov (United States)

    Tsuge, Masashi; Tseng, Chih-Yu; Lee, Yuan-Pern

    2018-02-21

    para-Hydrogen (p-H 2 ) serves as a new host in matrix-isolation experiments for an investigation of species of astrochemical interest. Protonated and mono-hydrogenated species are produced upon electron bombardment during deposition of p-H 2 containing a precursor in a small proportion. The applications of this novel technique to generate protonated polycyclic aromatic hydrocarbons (H + PAH), protonated polycyclic nitrogen heterocycles (H + PANH), and their neutral counterparts, which are important in the identification of interstellar unidentified infrared emission bands, demonstrate its superiority over other methods. The clean production with little fragmentation, ease of distinction between protonated and neutral species, narrow lines and reliable relative infrared intensities of the lines, and broad coverage of the spectral range associated with this method enable us to assign the isomers unambiguously. The application of this method to the protonation of small molecules is more complicated partly because of the feasible fragmentation and reactions, and partly because of the possible proton sharing between the species of interest and H 2 , but, with isotopic experiments and secondary photolysis, definitive assignments are practicable. Furthermore, the true relative infrared intensities are critical to a comparison of experimental results with data from theoretical calculations. The spectra of a proton-shared species in solid p-H 2 might provide insight into a search for spectra of proton-bound species in interstellar media. Investigations of hydrogenated species involving the photolysis of Cl 2 or precursors of OH complement those using electron bombardment and provide an improved ratio of signal to noise. With careful grouping of observed lines after secondary photolysis and a comparison with theoretical predictions, various isomers of these species have been determined. This photolytic technique has been applied in an investigation of hydrogenated PAH and

  1. Application of NIR - CRDS for state selective study of recombination of para and ortho H{sub 3}{sup +} ions with electrons in low temperature plasma

    Energy Technology Data Exchange (ETDEWEB)

    Varju, J; Roucka, S; KotrIk, T; Plasil, R; Glosik, J, E-mail: Juraj.Glosik@mff.cuni.c [Charles University, Faculty of Mathematics and Physics, Department of Surface and Plasma Science, V Holesovickach 2, Prague 8 (Czech Republic)

    2010-05-01

    We present a study of H{sub 3}{sup +} recombination performed at 77 K on the two lowest rotational levels of this ion, which belong to its two different nuclear spin states of the studied ion. A near infrared cavity ring-down spectrometer ({approx}1381 nm, CRDS arrangement) has been used to obtain the time evolution of concentration of both states. From the overall ion density decay during the afterglow we obtained the binary recombination rate coefficient {alpha}{sub bin} (77 K) = 1.2x10{sup -7} cm{sup 3}s{sup -1}. We have also observed ternary helium assisted recombination of both para and ortho H{sub 3}{sup +}. The process is very slow (at 77 K) and the obtained ternary recombination rate coefficient is in contradiction with the theoretical prediction. It is the first time that the binary and ternary H{sub 3}{sup +} recombination rate coefficient was measured at a known population of para and ortho H{sub 3}{sup +} ions in decaying plasma.

  2. Determination of the extractive capacity of para-tert butyl calix[8]arene octa-phosphinoylated towards uranyl ions from an aqueous-acidic-salty medium

    International Nuclear Information System (INIS)

    Serrano V, E. C.

    2011-01-01

    The extraction properties of octa-phosphinoylated para-tert butyl calix[8]arene (prepared in the laboratory) in chloroform towards uranyl ions from an aqueous-acidic-salty medium (HNO 3 -3.5 NaNO 3 ) containing uranyl nitrate salt, was investigated. Two spectroscopic techniques UV/Vis and Luminescence were used for this study. The latter permitted analyze the fluorescence from the uranyl ions influenced by the surrounding medium. Both permitted to learn about the power of this calixarene as extractant towards the mentioned ions. Its extraction ability or capability using this calixarene at 5.91 x 10 -4 M towards the uranyl ions was 400% as determined by UV/Vis while fluorescence revealed 100% of uranyl ion extraction. A closed analysis of the results obtained by using these techniques revealed that the stoichiometry of the main extracted species was 1calixarene:2 uranyl ions. The loading capacity of the calixarene ligand towards the uranyl ions was also investigated using both techniques. UV/Vis resulted to be inadequate for quantifying exactly the loading capacity of the calixarene whereas luminescence was excellent indeed, using a 5.91 x 10 -4 M calixarene concentration, its loading capacity was 0.157 M of free uranyl ions from 0.161 M of uranyl ions present in the aqueous-acidic-salty medium. The extracts from the ability and capacity studies were concentrated to dryness, purified and the dried extracts were analyzed by infrared and neutron activation analysis. By these techniques it was demonstrated that during the extraction of the uranyl ions by the calixarene ligand they form thermodynamically and kinetically stable complexes, since in the solid state, the 1:2, calixarene; uranyl ions stoichiometry was kept with the minimum formula: (UO 2 ) 2 B 8 bL 8 (NO 3 ) 4 (H 2 O) 4 CHCl 3 (CH 3 OH) 3 the methanol molecules come from its purification. It is proposed that B 8 bL 8 calixarene in chloroform medium is a good extractant for the treatment of nuclear wastes or

  3. Fabrication of nano porous with heavy ions in plastics for the oil industry; Fabricacion de nano poros con iones pesados en plasticos para la industria petrolera

    Energy Technology Data Exchange (ETDEWEB)

    Balcazar, M.; Tavera, L.; Mendoza, D.; Mut, A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: mbg@nuclear.inin.mx

    2003-07-01

    The natural gas has undesirable concentrations of other gases like the nitrogen that reduces the heat capacity of the gas. It is required to develop separation technology to increase the caloric value of the gas. Among the technology in development for the separation of these gases there are the nano membranes; these are polymeric material that when synthesizing them form nano pores that allow the selective separation of the gas. Another form of creating these nano pores with uniform and controlled pore size, is irradiating a polymeric material with heavy ions. The energy loss of the heavy ion produces cylindrical damages around its trajectory in a diameter among 30 x 10{sup -10} m and 100 x 10{sup -10} m. This damage breaks the chains of the polymer making it susceptible to the corrosion of appropriate chemical agents that allow to create a pore of the size of some nanometers in the polymer. The basic mechanisms of the interaction of the ions with the polymer are important for the controlled creation, the observation and analysis of these nano pores. One of the more appropriate techniques for the visualization and analysis of the geometry of the produced damages, it is the scanning electron and of the atomic force microscopies. The present work has as objective to define the basic parameters of the interaction of the ion with the polymer that intervene in the fabrication of this nano pores. The conditions of the chemical corrosion process are presented for the creation of micro pores in two polymers CR39 and Makrofol produced by fission fragments and alpha particles. A characterization of the diameters and of the damages profile is make. The obtained results are related with the mechanisms of loss of energy of the ions in the matter and the particles identification in function of the damage geometry. (Author)

  4. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO{sub 4}: Dy + Ptfe; Intercomparacion dosimetrica en unidades de cobalto 60 usando cristales de TLD-100 y CaSO{sub 4}: Dy + PTFE

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E. [Universidad Autonoma Metropolitana Xochimilco, Mexico D.F. (Mexico); Azorin N, J. [Universidad Autonoma Metropolitana Iztapalapa, Mexico D.F. (Mexico); Perez P, M.A. [Instituto Nacional de Cancerologia, Mexico D.F. (Mexico); Castillo H, M. [Centro Medico Nacional 20 de Noviembre, ISSSTE, Mexico D.F. (Mexico); Flores F, F. [Unidad de Oncologia, Centro Medico Nacional, IMSS, Mexico D.F. (Mexico); Guzman R, L.V. [Unidad de Oncologia, Hospital General de Mexico, Mexico D.F. (Mexico)

    1999-07-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO{sub 4}: Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  5. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO4: Dy + Ptfe

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin N, J.; Perez P, M.A.; Castillo H, M.; Flores F, F.; Guzman R, L.V.

    1999-01-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO 4 : Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  6. The linearity of the high temperature peaks in TLD100 for thermal neutrons and gamma rays irradiation

    International Nuclear Information System (INIS)

    Weinstein, M.; German, U.; Abraham, A.; Dubinsky, S.; Alfassi, Z.B.

    2004-01-01

    One of the problems that complicates the routine personal TL dosimetry with LiF:Mg,Ti, is the complexity of its glow curves, as many as 10 to 14 peaks have been identified at temperatures from 60 degree C to 400 degree C. Each peak may have different dosimetric characteristics, and may be differently dependent on a variety of factors, as the annealing procedure and type of radiation. It was observed already in the early years of TLD research, that when LiF is exposed to higher LET radiations, an enhanced sensitivity is obtained for the peaks in the 250 degree C region (6 and 7), compared to the usual dosimetry peaks (4 and 5, at about 200 degree C), and it was proposed to use this difference for mixed thermal neutron and gamma dosimetry. The development of sophisticated tools for glow curve analysis, especially the Computerized Glow Curve Deconvolution (CGCD), enabled accurate separation of the specific peaks and intensified the research on the various peaks properties. However, some major obstacles were detected, which diminished the attractiveness of using the high temperature peaks to discriminate between the neutron and gamma dose components. Peak 6 is very near to peak 5, which is the main dosimetry peak, and its separation from peak 5 is difficult, especially when measuring low doses. Peak 7 is more intense and well resolved, but its response was reported to be supra-linear, and therefore its use for neutron-gamma mixed dosimetry is questionable. In the present work we investigated the linearity of two regions of interest, one containing the main information from the peaks 6 and 7 and the other containing the main information from the main dosimetry peaks 4 and 5, after irradiation of the crystals with thermal neutrons and gamma rays. The irradiation was performed to relatively low doses, up to about 50mSv, which are the practical levels encountered in routine situations

  7. Óxidos de estaño: nuevos anodos para baterías de Ion-Litio

    OpenAIRE

    Morales Palomino, Julián; Sánchez, L.

    1999-01-01

    La reacci n entre el litio y xidos aleaciones de esta o es reversible cuando se realiza por m todos electroqu micos y a bajos potenciales con respecto al electrodo de litio. Esta propiedad permite el uso de estos materiales como electrodos negativos en el dise o y construcci n de bater as tipo ion-litio. En el caso de xidos de esta o la reacci n de inserci n de litio en la matriz conduce a la formaci n de aleaciones Li-Sn. La presencia de agregados grandes de tomos de esta o, fo...

  8. Microscale adaptation of the potentiometric method with ion-selective electrode for the quantification of fluoride; Adaptacion a microescala del metodo potenciometrico con electrodo ion selectivo para la cuantificacion de fluoruro

    Energy Technology Data Exchange (ETDEWEB)

    Guevara Ruiz, Paulina; Ortiz Perez, Maria Deogracias [Laboratorio de Bioquimica, Facultad de de Medicina, Universidad Autonoma de San Luis Potosi, San Luis Potosi, San Luis Potosi, (Mexico)]. E-mail: mdortiz@uaslp.mx

    2009-05-15

    Similarly to other countries, ground water from Mexico is naturally polluted by fluoride. The main effects of fluoride at typical ground water concentrations are dental fluorosis, neurological deficits and reproductive disorders. In order to verify that the fluoride concentration is within the allowed guideline in Mexico (NOM 127 and 201), it is important to monitor fluoride levels in water and commercial beverages. The aim of this work is to develop a modification of the standard potentiometric method for fluoride determination in water, in order to reduce costs and amount of potentially toxic waste substances. Both methods were validated, the standard potentiometric method with the ion selective electrode and the microscale modification proposed in this paper. The methods were compared using statistic tests and graphics, followed by the comparison of 125 samples of commercial bottled water sold in the city of San Luis Potosi. Optimal results were obtained for the validation of both methods, and the microscale modification showed statistically identical results to those obtained with the standard method in all samples of bottled water. The microscale modification is a good alternative for fluoride assessment in water and beverages, and it represents a 95 % reduction of costs and chemical waste. [Spanish] En varios paises, incluido Mexico se presenta una contaminacion natural con fluoruro en agua subterranea; los principales efectos en la salud observados en poblacion expuesta a concentraciones mayores al valor permisible (que en Mexico es de 1.5 mg/L) son la fluorosis dental y esqueletica, asi como dano reproductivo y neurologico. En varios estados de la republica Mexicana, este problema es aun desconocido, de ahi la necesidad de evaluar las concentraciones de fluoruro en agua de consumo en varias comunidades. Asi, el objetivo de este trabajo es desarrollar un metodo a microescala para la determinacion de fluoruro en agua, que al reducir la cantidad de reactivo y

  9. BaSO4:Eu as an energy independent thermoluminescent radiation dosimeter for gamma rays and C6+ ion beam

    Science.gov (United States)

    Sharma, Kanika; Bahl, Shaila; Singh, Birendra; Kumar, Pratik; Lochab, S. P.; Pandey, Anant

    2018-04-01

    BaSO4:Eu nanophosphor is delicately optimized by varying the concentration of the impurity element and compared to the commercially available thermoluminescent dosimeter (TLD) LiF:Mg,Ti (TLD-100) and by extension also to CaSO4:Dy (TLD-900) so as to achieve its maximum thermoluminescence (TL) sensitivity. Further, the energy dependence property of this barite nanophosphor is also explored at length by exposing the phosphor with 1.25 MeV of Co-60, 0.662 MeV of Cs-137, 85 MeV and 65 MeV of Carbon ion beams. Various batches of the phosphor at hand (with impurity concentrations being 0.05, 0.10, 0.20, 0.50 and 1.00 mol%) are prepared by the chemical co-precipitation method out of which BaSO4:Eu with 0.20 mol% Eu exhibits the maximum TL sensitivity. Further, the optimized nanophosphor exhibits a whopping 28.52 times higher TL sensitivity than the commercially available TLD-100 and 1.426 times higher sensitivity than TLD-900, a noteworthy linear response curve for an exceptionally wide range of doses i.e. 10 Gy to 2 kGy and a simple glow curve structure. Furthermore, when the newly optimized nanophosphor is exposed with two different energies of gamma radiations, namely 1.25 MeV of Co-60 (dose range- 10-300 Gy) and 0.662 MeV of Cs-137 (dose range- 1-300 Gy), it is observed that the shape and structure of the glow curves remain remarkably similar for different energies of radiation while the TL response curve shows little to no variation. When exposed to different energies of carbon ion beam BaSO4:Eu displays energy independence at lower doses i.e. from 6.059 to 14.497 kGy. Finally, even though energy independence is lost at higher doses, the material shows high sensitivity to higher energy (85 MeV) of carbon beam compared to the lower energy (65 MeV of C6+) and saturation is apparent only after 121.199 kGy. Therefore the present nanophosphor displays potential as an energy independent TLD.

  10. VALIDACIÓN DE DOS MÉTODOS PARA LA DETERMINACIÓN DE ION AMONIO Y SULFATO INORGÁNICO COMO INDICADORES DE RIESGO DE LITIASIS RENAL EN ORINA

    OpenAIRE

    Fernández, Verónica Guillermina; Sobrero, María Silvina; Marsili, Nilda Raquel; Bonifasino, Rosina; Brissón, Cecilia; Pedro, Angela; Denner, Susana

    2017-01-01

    La evaluación metabólica del paciente litiásico implica la determinación de inhibidores y promotores de la litogénesis. Entre los últimos están el ion sulfato inorgánico y el ion amonio. El incremento en la excreción urinaria de sulfato contribuye a la formación de cálculos cálcicos, la de amonio los cálculos de estruvita y urato ácido de amonio. El objetivo del trabajo fue modificar y validar dos métodos analíticos tradicionales para su cuantificación. Para el primero modificó el método turb...

  11. Technical feasibility of using silver and copper ions electro generated in the microbiological control of cooling systems; Factibilidad tecnica para emplear iones plata y cobre electrogenerados en el control microbiologico de los sistemas de enfriamiento

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Susana M; Martinez Meza, Esteban; Alvarez Gallegos, Alberto [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    2001-07-01

    sistema continuo el pH se mantuvo en el intervalo de pH de 7 a 8 mediante la adicion de acido sulfurico y se conservo un delta de temperatura de 10 (27 {+-} 5 ). El pH, la conductividad y la temperatura se midieron en forma continua. Se muestran graficas de efecto de iones plata/cobre sobre el aniquilamiento de bacterias coliformes totales y coliformes fecales se da como figura el efecto de la concentracion del ion metalico plata sobre el aniquilamiento de bacterias relacionadas con fierro. Se puede concluir que los sistemas de planta, plata/cobre y cobre estudiados resultaron ser una buena alternativa con un minimo impacto ambiental para sustituir el cloro en los sistemas de enfriamiento. Estos sistemas lograron abatir a las poblaciones bacterianas promotoras de la corrrosion influenciada microbiologicamente y del ensuciamiento biologico a niveles de 1000 ufc/mL y menores compitiendo con los tratamientos de aguas de enfriamiento convencionales. (abstract truncated)

  12. Production of LiF films for dosimetric thermoluminescence application; Producao de filmes de LiF para aplicacao em dosimetria termoluminescente

    Energy Technology Data Exchange (ETDEWEB)

    Mauricio, Claudia Lucia de Pinho

    2000-12-01

    This work studies the LiF monolayer and multilayer polycrystalline film's dosimetric properties. The films were produced by electron beam evaporation technique in aluminium and stainless steel substrates maintained at several temperatures. As dosimetric variable, the intensity of the thermoluminescent (TL) glow curve of the films was used. effects of the substrate type and temperature; of the addition of layers of Mg F{sub 2} NaF and Cu F{sub 2} to the LiF films; and of thermal treatments in the TL response of the produced films were studied. The microstructural characterization of the films was accomplished through measures of scanning electronic microscopy and grazing incidence X-rays diffraction analysis. The dosimetric characterization was made of gamma radiation exposure in a {sup 60} Co source, with kerma from 0,1 to 500 Gy. Studies of reproducibility, homogeneity, stability and other environmental effects were also made. LiF and Cu F{sub 2}: LiF; Mg F{sub 2} films were the only ones that presented mechanical stability and reproducibility of the TL emission. There is a strong indication of some correlation between the residual tension fields inside the films and the intensity of its TL emission peaks. LiF monolayer films present supralinear behaviour from 0,2 to 100 Gy. These films present a main TL glow peak around 150 deg C, whose half-time is about 30 days. Its volumetric sensitivity can reach about 60 times that of LiF powder and about 0,25 that of TLD100 (LiF:Mg, Ti commercial dosimeter from Harshaw Chemical Co.) The homogeneity and reproducibility inside a same film batch is better than 12% for 95% confidence level. Cu F{sub 2} : LiF: Mg F{sub 2} films present linear behaviour from 3 to 500 Gy and its main TL glow peak around 200 deg C did not present any fading for a a period of 30 days, in laboratory conditions. This glow peak is characteristic of the Mg doping of LiF, which confirms the diffusion of Mg ions from the Mg F{sub 2} layer to the Li

  13. Una plataforma MEMS para la medición in-situ y en tiempo real de la tensión/esfuerzo inducido electroquímicamente en el electrodo de una bateria de litio-ion

    OpenAIRE

    Barón, Sergio D.

    2015-01-01

    En este trabajo se reporta la primera demostración exitosa de las capacidades de sensado de una plataforma MEMS para la caracterización in-situ de los procesos de expansión/contracción reversible inducida electroquímicamente en electrodos de baterías de litio-ion (LIB). La plataforma consiste en un arreglo de membranas flexibles que cambian su forma dinámicamente debido al intercalado/expansión y extracción/contracción de litio. El cambio de curvatura de la membrana se mide por el principio d...

  14. Determination of the extractive capacity of para-tert butyl calix[8]arene octa-phosphinoylated towards uranyl ions from an aqueous-acidic-salty medium; Determinacion de la capacidad extractiva del p-ter-butilocalix[8]areno octa-fosfinoilado hacia iones uranilo de un medio acuo-acido salino

    Energy Technology Data Exchange (ETDEWEB)

    Serrano V, E. C.

    2011-07-01

    The extraction properties of octa-phosphinoylated para-tert butyl calix[8]arene (prepared in the laboratory) in chloroform towards uranyl ions from an aqueous-acidic-salty medium (HNO{sub 3}-3.5 NaNO{sub 3}) containing uranyl nitrate salt, was investigated. Two spectroscopic techniques UV/Vis and Luminescence were used for this study. The latter permitted analyze the fluorescence from the uranyl ions influenced by the surrounding medium. Both permitted to learn about the power of this calixarene as extractant towards the mentioned ions. Its extraction ability or capability using this calixarene at 5.91 x 10{sup -4} M towards the uranyl ions was 400% as determined by UV/Vis while fluorescence revealed 100% of uranyl ion extraction. A closed analysis of the results obtained by using these techniques revealed that the stoichiometry of the main extracted species was 1calixarene:2 uranyl ions. The loading capacity of the calixarene ligand towards the uranyl ions was also investigated using both techniques. UV/Vis resulted to be inadequate for quantifying exactly the loading capacity of the calixarene whereas luminescence was excellent indeed, using a 5.91 x 10{sup -4} M calixarene concentration, its loading capacity was 0.157 M of free uranyl ions from 0.161 M of uranyl ions present in the aqueous-acidic-salty medium. The extracts from the ability and capacity studies were concentrated to dryness, purified and the dried extracts were analyzed by infrared and neutron activation analysis. By these techniques it was demonstrated that during the extraction of the uranyl ions by the calixarene ligand they form thermodynamically and kinetically stable complexes, since in the solid state, the 1:2, calixarene; uranyl ions stoichiometry was kept with the minimum formula: (UO{sub 2}){sub 2}B{sub 8}bL{sup 8}(NO{sub 3}){sub 4}(H{sub 2}O){sub 4}CHCl{sub 3}(CH{sub 3}OH){sub 3} the methanol molecules come from its purification. It is proposed that B{sub 8}bL{sup 8} calixarene in

  15. Comparative study of adsorbents for the removal of fluoride ions from water use and consumption in Mexico; Estudio comparativo de adsorbentes para la remocion de iones fluoruro del agua de uso y consumo en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Teutli S, E. A.

    2014-07-01

    Although fluoride is essential for health many studies have shown it is associated with some health problems, such as fluoro sis, thyroid disorder, neurological disease, Alzheimer, pineal gland and cancer. One of the major routes of exposure is through drinking water. The World Health Organization (Who) allows only 1.5 mg/L as a safe limit for fluoride ions in drinking water and the EPA U. S. Environmental Protection Agency has recently proposed 0.7 mg/L. In some cases, the water extracted from deep wells has concentrations of fluoride ions above 1.5 mg/L (NOM-127-SSA1-2000) which is the permissible limit of water for human use and consumption (whuc). In several countries, there are high concentrations of fluoride ions due to the geological distribution of fluorine-rich rocks. In our country we can find several states that have concentrations higher than 1.5 mg/L of fluoride ions in water, such as Aguascalientes, Zacatecas, Chihuahua, Coahuila, Durango, Guanajuato, Sonora, Jalisco and San Luis Potosi. Various technologies have been proposed to remove fluoride ions from water, such as adsorption, ion exchange, reverse osmosis, nano filtration, electrodialysis, dialysis and electrocoagulation. Sorption is superior to other techniques in terms of initial cost, simplicity of design and ease of operation. In this work systematic studies were done considering the aspects mentioned above, in order to determine the adsorbents properties and most suitable conditions for the removal of fluoride ions from whuc. It is important to note that to date no adsorption treatments for the removal of fluoride ions from water for human use and consumption in our country is done, although there are established methodologies, they have not been implemented because of their high costs. In this work an integral study was done on the removal of fluoride ions from water for human use and consumption. A comparative study of hematite, calcite and zeolite as adsorbents was performed to develop a

  16. Establishment of the conditions for the determination of the concentration of the uranyl ion in perchloric media by Fluorescence; Establecimiento de las condiciones para la determinacion de la concentracion del ion uranilo en medio perclorico por Fluorescencia

    Energy Technology Data Exchange (ETDEWEB)

    Contreras R, A.; Ordonez R, E.; Fernandez V, S.M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: contraida@yahoo.com.mx

    2004-07-01

    The influence of the p H is reported in the spectra of luminescence of the ion uranyl in sodium perchlorate 2M. The best spectra were observed to ph <3 that to neutral and basic p Hs this is explained by the present species. They were carried out four calibration curves for the uranyl in perchloric acid media, taking into account the area under the curve, the maximum height of two characteristic peaks of this ion, in those that one observes a better correlation with the maximum height of the peak located to 486.7 nm. (Author)

  17. Ion chamber-electrometer measurement system for radiation protection tests in X-ray equipment for interventional procedures; Sistema de medicao camara de ionizacao-eletrometro para ensaios de protecao radiologica em equipamentos de raios X para procedimentos intervencionistas

    Energy Technology Data Exchange (ETDEWEB)

    Bottaro, Marcio

    2012-07-01

    A new parallel plate ionization chamber with volume of 500 cc and an electrometer with digital interface for data acquisition, configuring an ion chamber electrometer measurement system, were developed to comply with specific requirements for compulsory radiation protection tests in interventional X-ray equipment. The ion chamber has as main characteristics: low cost, mechanical strength and response variation with beam energy of less than 5% in the 40 kV to 150 kV range. The electrometer has a high gain (5x10{sup 8} V/A) transimpedance amplifier circuit and a data acquisition and control system developed in LabVIEW Registered-Sign platform, including an integrated power supply for the ion chamber bias with adjustable DC voltage output from O to 1000 V and an air density correction system. Electric field calculations, laboratory measurements in standard beams and computational simulations of radiation interactions in chamber volume with Monte Carlo Method were employed in the elaborated methodology of the ion chamber development, which was tested and validated. It was also developed a simplified methodology for electrometer calibration that assures metrological trustworthiness of the measurement system. Tests for the system performance evaluation as environmental influence response, energy response, angular dependency, linearity and air kerma and air kerma rate dependency were performed according to international standards and requirements. Additionally, for a detailed evaluation of the developed ion chamber, simulations with various scattered radiation spectra were performed. The system was applied in leakage radiation, residual radiation and scattered radiation tests, being compared with other reference systems and validated for laboratorial test routine. (author)

  18. Óxidos de estaño: nuevos ánodos para baterías de Ion-Litio

    OpenAIRE

    Morales, J.; Sánchez, L.

    1999-01-01

    The electrochemical reaction between Li and tin-based compounds, is reversible and takes place at low potentials measured against the Li electrode. This feature allows the use of these materials as negative electrodes in the manufacturing of Li-ion batteries. The lithium insertion in the tin oxides leads to the formation of Li-Sn alloys. The presence of large tin clusters, formed during the reaction, causes the cracking and crumblimg of the anodic material and the electronic contact between t...

  19. Development of a parallel plate ion chamber for radiation protection level; Desenvolvimento de uma camara de ionizacao de placas paralelas para protecao radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Bottaro, Marcio; Landi, Mauricio [Universidade de Sao Paulo (STEEE/IEE/USP), SP (Brazil). Inst. de Eletrotecnica e Energia. Secao Tecnica de Ensaios em Equipamentos Eletromedicos; Moralles, Mauricio [Instituto de Pesquisas Energeticas e Nucleares (CRPq/IPEN/CNEN-SP), SP (Brazil). Centro do Reator Nuclear de Pesquisas

    2011-07-01

    A new parallel plate vented ion chamber is proposed in this paper. The application of this chamber was primarily intended to the measurement of stray radiation in interventional procedures, but the energy response of about 2.6%, which was obtained in the first prototype, on the range from 40 to 150 kV using ISO 4037-1 narrow qualities, provided the possibility of a wide modality application on radiation protection. Primary studies with Maxwell 2D electromagnetic field simulator revealed an optimized model regarding effective volume and saturation voltage levels, which conferred to the ion chamber a dual entrance window feature. The development of this ion chamber has the main contribution of Monte Carlo calculations as a support tool to the establishment of the effective volume of the chamber and determination of the best materials for housing mounting and conductive elements, such as guard rings, electrode, and windows. Even the composition of the conductive layers, which would be neglected due to their very small thicknesses (about 35 {mu}m), had important influence on the results and could be better understood with Monte Carlo N-Particle Transport Code System (MCNP) simulations. (author)

  20. A liquid-drop model for the heavy-ion fusion below the Coulomb barrier; Um modelo de gota liquida para a fusao de ions pesados abaixo da barreira coulombiana

    Energy Technology Data Exchange (ETDEWEB)

    Aguiar, Carlos Eduardo Magalhaes de

    1988-03-01

    The enhancement of sub-barrier fusion observed in heavy ion collisions is studied in a liquid-drop model. It is shown that shape degrees of freedom related to neck formation play an important role in the fusion process, and increase the low energy fusion rates. The model predictions are in a quite satisfactory agreement with the experimental data, and major discrepancies seem to be found only for those systems where specific nuclear structure effects should also be considered. (author). 83 refs, 54 figs.

  1. Óxidos de estaño: nuevos ánodos para baterías de Ion-Litio

    Directory of Open Access Journals (Sweden)

    Morales, J.

    1999-12-01

    Full Text Available The electrochemical reaction between Li and tin-based compounds, is reversible and takes place at low potentials measured against the Li electrode. This feature allows the use of these materials as negative electrodes in the manufacturing of Li-ion batteries. The lithium insertion in the tin oxides leads to the formation of Li-Sn alloys. The presence of large tin clusters, formed during the reaction, causes the cracking and crumblimg of the anodic material and the electronic contact between the particles is lost. The electrochemical performance of these materials can be optimized by controlling the growing and size of tin aggregates.

    La reacción entre el litio y óxidos o aleaciones de estaño es reversible cuando se realiza por métodos electroquímicos y a bajos potenciales con respecto al electrodo de litio. Esta propiedad permite el uso de estos materiales como electrodos negativos en el diseño y construcción de baterías tipo ion-litio. En el caso de óxidos de estaño la reacción de inserción de litio en la matriz conduce a la formación de aleaciones Li-Sn. La presencia de agregados grandes de átomos de estaño, formados durante la inserción de litio, origina la fragmentación y el desmoronamiento del material anódico. Este efecto provoca la pérdida del contacto eléctrico entre partículas, con el consiguiente deterioro de la batería. La optimización del rendimiento electroquímico de estos materiales se puede lograr mediante el control del crecimiento y tamaño de los agregados de estaño.

  2. Establishment of a luminescence technique for the quantification of uranyl ion in a KNO{sub 3} media; Establecimiento de una tecnica de luminiscencia para la cuantificacion del ion uranilo en medio de KNO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Contreras R, A. [UAEM, A.P. 2-139, 50000 Toluca, Estado de Mexico (Mexico); Fernandez V, S.M.; Ordonez R, E. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-07-01

    The study of the storage of high level radioactive residuals that contain uranium, it makes necessary that in the sorption studies is counted with a reliable technique and not pollutant for the quantification of this element. Presently work intends a technique for the quantification of the uranyl ion using the luminescence technique, which allows not to generate radioactive or industrial residuals. It was used a solution of uranyl nitrate in KNO{sub 3} 0.5 M media. The solutions were adjusted to a pH of 1.48+0.03. A statistical study for the analysis of the data of fluorescence, about the maximum value of the peak, total area under the curve and area under the it curves is shown, being the best correlation for the concentration curve versus maximum of the peak, adjusted with a polynomial of second grade. The study of stability of the solutions with regard to the time is reported and that the technique proposal works for the interval of concentrations among 1 x 10{sup -2} M and 6 x 10{sup -5} M. (Author)

  3. Obtention of a thermoluminescent material for dosimetry of ionizing radiation; Obtencion de un material termoluminiscente para dosimetria de la radiacion ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, P.R

    1990-07-01

    The thermoluminescent dosemeters are small crystals which suffer changes in their structure by the radiation effect, being displaced the electrons toward higher energy levels. On heating the previously irradiated crystals, the electrons come back to their base state emitting light photons. The light quantity emitted is proportional to the received radiation dose. The light quantity emitted is proportional to the received radiation dose. The lithium fluoride is one of the thermoluminescent materials considered as tissue equivalents by having a low effective atomic number (Z{sub ef}). At present, the more used commercial product used of this type is the TLD-100*. In this work the obtained results in the preparation of the lithium fluoride thermoluminescent material are presented. This is activated with magnesium (Mg) and titanium (Ti), which we have labelled as: LiF: Mg, Ti. The results from the tests performed for verifying his thermoluminescent properties are presented too, as powder form as in pellets form. These tests were performed in simultaneous form with TLD-100 samples, which is considered as reference. The LiF: Mg, Ti thermoluminescent material manufactured in the ININ presents similar dosimetric characteristics to those ones of the TLD-100. Therefore being able to replace the imported dosemeters. * (TLD-100 is a commercial trademark registered by Harshaw/Filtrol (US) for LiF: Mg, Ti Tl dosemeters) (Author)

  4. Desempenho de novilhas leiteiras sob manejo para crescimento compensatório recebendo suplementação com ionóforo Performance of dairy heifers on a compensatory growth regime supplemented with monensin

    Directory of Open Access Journals (Sweden)

    Patrícia Barcellos Costa

    2007-04-01

    Full Text Available Objetivou-se avaliar a influência do manejo para crescimento compensatório e da suplementação com ionóforo sobre o desempenho de novilhas leiteiras. Foram utilizadas 20 novilhas Pardo-Suíças puras, com peso inicial de 200 kg e cinco meses de idade. Os tratamentos foram arranjados em um esquema fatorial (2 x 2 e os animais foram alocados aleatoriamente em cada uma das combinações. O fator 1 consistiu dos sistemas de alimentação (convencional e crescimento compensatório e o fator 2, da utilização ou não de ionóforo (200 mg de monensina/animal/dia. Os animais do sistema convencional receberam alimentação ad libitum, enquanto os do sistema de crescimento compensatório foram submetidos a um manejo nutricional com dois períodos distintos: período de restrição energética (90 dias, P1 e período de realimentação (60 dias, P2. A eficiência de conversão de MS e EM consumida em ganho de peso diário foi menor durante o período de realimentação. Não houve diferença para as variáveis relacionadas ao balanço de nitrogênio dos animais do sistema convencional e daqueles submetidos ao manejo para crescimento compensatório. A inclusão de ionóforo na dieta das novilhas resultou em menor excreção de nitrogênio (N urinário e, conseqüentemente, a retenção de N foi maior no período de restrição e menor no período de realimentação, o que refletiu na eficiência de utilização do N consumido. Não houve efeito dos sistemas, da utilização de ionóforo ou do período sobre os parâmetros morfo-estruturais estudados e sobre o peso ao final do período experimental. Novilhas em crescimento compensatório apresentaram maior ganho de peso diário ao 135º e 150º dias do período experimental, em comparação às do sistema convencional.The objective of this trial was to compare the effect of different feeding strategies with or without ionophore (monensin supplementation on performance of dairy heifers. Twenty Brown

  5. Ion Colliders

    CERN Document Server

    Fischer, W

    2014-01-01

    High-energy ion colliders are large research tools in nuclear physics to study the Quark-Gluon-Plasma (QGP). The range of collision energy and high luminosity are important design and operational considerations. The experiments also expect flexibility with frequent changes in the collision energy, detector fields, and ion species. Ion species range from protons, including polarized protons in RHIC, to heavy nuclei like gold, lead and uranium. Asymmetric collision combinations (e.g. protons against heavy ions) are also essential. For the creation, acceleration, and storage of bright intense ion beams, limits are set by space charge, charge change, and intrabeam scattering effects, as well as beam losses due to a variety of other phenomena. Currently, there are two operating ion colliders, the Relativistic Heavy Ion Collider (RHIC) at BNL, and the Large Hadron Collider (LHC) at CERN.

  6. Ion colliders

    International Nuclear Information System (INIS)

    Fischer, W.

    2010-01-01

    Ion colliders are research tools for high-energy nuclear physics, and are used to test the theory of Quantum Chromo Dynamics (QCD). The collisions of fully stripped high-energy ions create matter of a temperature and density that existed only microseconds after the Big Bang. Ion colliders can reach higher densities and temperatures than fixed target experiments although at a much lower luminosity. The first ion collider was the CERN Intersecting Storage Ring (ISR), which collided light ions (77Asb1, 81Bou1). The BNL Relativistic Heavy Ion Collider (RHIC) is in operation since 2000 and has collided a number of species at numerous energies. The CERN Large Hadron Collider (LHC) started the heavy ion program in 2010. Table 1 shows all previous and the currently planned running modes for ISR, RHIC, and LHC. All three machines also collide protons, which are spin-polarized in RHIC. Ion colliders differ from proton or antiproton colliders in a number of ways: the preparation of the ions in the source and the pre-injector chain is limited by other effects than for protons; frequent changes in the collision energy and particle species, including asymmetric species, are typical; and the interaction of ions with each other and accelerator components is different from protons, which has implications for collision products, collimation, the beam dump, and intercepting instrumentation devices such a profile monitors. In the preparation for the collider use the charge state Z of the ions is successively increased to minimize the effects of space charge, intrabeam scattering (IBS), charge change effects (electron capture and stripping), and ion-impact desorption after beam loss. Low charge states reduce space charge, intrabeam scattering, and electron capture effects. High charge states reduce electron stripping, and make bending and acceleration more effective. Electron stripping at higher energies is generally more efficient. Table 2 shows the charge states and energies in the

  7. Ion colliders

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, W.

    2011-12-01

    Ion colliders are research tools for high-energy nuclear physics, and are used to test the theory of Quantum Chromo Dynamics (QCD). The collisions of fully stripped high-energy ions create matter of a temperature and density that existed only microseconds after the Big Bang. Ion colliders can reach higher densities and temperatures than fixed target experiments although at a much lower luminosity. The first ion collider was the CERN Intersecting Storage Ring (ISR), which collided light ions [77Asb1, 81Bou1]. The BNL Relativistic Heavy Ion Collider (RHIC) is in operation since 2000 and has collided a number of species at numerous energies. The CERN Large Hadron Collider (LHC) started the heavy ion program in 2010. Table 1 shows all previous and the currently planned running modes for ISR, RHIC, and LHC. All three machines also collide protons, which are spin-polarized in RHIC. Ion colliders differ from proton or antiproton colliders in a number of ways: the preparation of the ions in the source and the pre-injector chain is limited by other effects than for protons; frequent changes in the collision energy and particle species, including asymmetric species, are typical; and the interaction of ions with each other and accelerator components is different from protons, which has implications for collision products, collimation, the beam dump, and intercepting instrumentation devices such a profile monitors. In the preparation for the collider use the charge state Z of the ions is successively increased to minimize the effects of space charge, intrabeam scattering (IBS), charge change effects (electron capture and stripping), and ion-impact desorption after beam loss. Low charge states reduce space charge, intrabeam scattering, and electron capture effects. High charge states reduce electron stripping, and make bending and acceleration more effective. Electron stripping at higher energies is generally more efficient. Table 2 shows the charge states and energies in the

  8. Inorganic ion exchangers based on manganese and potassium for recovery and removal of pollutant metals of aqueous effluents; Trocadores ionicos inorganicos a base de manganes e potassio para recuperacao e remocao de metais poluentes de efluentes aquosos

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Jacinete Lima dos

    2001-07-01

    This work presents a study on the synthesis, characterization and ion exchange properties of inorganic ion exchangers based on manganese and potassium. The ion exchangers were synthesized by calcination of the mixture of manganese(II) oxalate and potassium oxalate and were characterized by granulometer distribution analysis, X-ray powder diffraction, infrared spectroscopy and scanning electron microscopic. From the data obtained in characterization it was observed that exist two distinguished groups of these materials. The first group belong to ion exchangers with up to 30% w/w potassium and the second group formed by the ion exchangers with more than 30% w / w of content of potassium in their compositions. The studies of adsorption of these materials showed that the adsorption of Cd{sup 2+} is a function of the following parameters as pH, concentration of Cd{sup 2+}, time of contact between the ion exchangers the concentration of the Cd{sup 2+} solution and the interference of other ions like Ni{sup 2+}. The great pH of adsorption for these materials occur in pH 9, the study of the influence of the cadmium concentration in the adsorption showed that for a group of exchangers the adsorption decreases with the increase of cadmium concentration and for the other group the adsorption increases with the increase of cadmium concentration. The kinetics of adsorption occur in a contact time between the ion exchangers and the Cd{sup 2+} solutions relatively short, at about 15 minutes is necessary to establish the equilibrium. The presence of Ni{sup 2+} as interfering ion decreases the adsorption of cadmium of 99,7% to 65%. These inorganic ion exchangers showed be good exchangers for Cd{sup 2+}. (author)

  9. ion irradiation

    Indian Academy of Sciences (India)

    Swift heavy ions interact predominantly through inelastic scattering while traversing any polymer medium and produce excited/ionized atoms. Here samples of the polycarbonate Makrofol of approximate thickness 20 m, spin coated on GaAs substrate were irradiated with 50 MeV Li ion (+3 charge state). Build-in ...

  10. Ion source

    International Nuclear Information System (INIS)

    1979-01-01

    The ion source comprises a cylindrically shaped chamber with a longitudinal outlet slot formed therein and two uniform anode wires which extend along the length of the chamber in the middle region thereof and which are symmetrically introduced with respect to the length axis of the chamber and the outlet groove, characterised in that at each outer end of the outlet groove at a nearly null potential or direct potential is introduced a mask, whereby the lowest distance between the inner and outer ends of the mask is equivalent to the breadth of the ion beam emitted from the source. (G.C.)

  11. Ion channeling

    International Nuclear Information System (INIS)

    Erramli, H.; Blondiaux, G.

    1994-01-01

    Channeling phenomenon was predicted, many years ago, by stark. The first channeling experiments were performed in 1963 by Davies and his coworkers. Parallely Robinson and Oen have investigated this process by simulating trajectories of ions in monocrystals. This technique has been combined with many methods like Rutherford Backscattering Spectrometry (R.B.S.), Particles Induced X-rays Emission (P.I.X.E) and online Nuclear Reaction (N.R.A.) to localize trace elements in the crystal or to determine crystalline quality. To use channeling for material characterization we need data about the stopping power of the incident particle in the channeled direction. The ratios of channeled to random stopping powers of silicon for irradiation in the direction have been investigated and compared to the available theoretical results. We describe few applications of ion channeling in the field of materials characterization. Special attention is given to ion channeling combined with Charged Particle Activation Analysis (C.P.A.A.) for studying the behaviour of oxygen atoms in Czochralski silicon lattices under the influence of internal gettering and in different gaseous atmospheres. Association between ion channeling and C.P.A.A was also utilised for studying the influence of the growing conditions on concentration and position of carbon atoms at trace levels in the MOVPE Ga sub (1-x) Al sub x lattice. 6 figs., 1 tab., 32 refs. (author)

  12. ION VATAMANU

    Directory of Open Access Journals (Sweden)

    l. Povar

    2012-12-01

    Full Text Available Ion Vatamanu was a chemist, writer and public figure. He was equally passionate about both his chosen fields of activity: chemistry and poetry. Chemistry, with its perfect equilibrium of logic and precision, provided inspiration for lyrical creativity, whereas poetry writing enlivened his imagination and passion for chemistry. He loved his parents. He adored his wife Elena, whom he often gifted a sea of flowers. He loved his daughters Mihaela, Mariana, and Leontina. He loved life, and he loved people.

  13. Ion source

    International Nuclear Information System (INIS)

    Saito, Fusao; Okuyama, Toshihisa; Suzuki, Yasuo.

    1996-01-01

    In a negative ion source having magnetic filters, bisecting magnetic fields are formed using electromagnets disposed at the outside of a plasma source. The position of the electromagnets is made adjustable and removable to optimize a negative ion generation efficiency. Further, a plurality of electromagnets are disposed in longitudinal direction of the plasma source, and the intensity of the magnetic fields of the filters in the longitudinal direction is made adjustable to control a beam distribution. Since uniform magnetic fields which bisect the plasma source can be formed by the electromagnets, and magnetomotive force of the electromagnets can be increased easily compared with that of permanent magnets, the magnetomotive force is changed to obtain appropriate filter magnetic fields easily. Then, optimum magnetic fields corresponding to the state of source plasmas can be generated by the control of the power source of the electromagnets, which also increases the negative ion drawing current density, thereby enabling to reduce the drawing area and size of the plasma source. (N.H.)

  14. Ion Beam Extraction by Discrete Ion Focusing

    DEFF Research Database (Denmark)

    2010-01-01

    An apparatus (900) and methods are disclosed for ion beam extraction. In an implementation, the apparatus includes a plasma source (or plasma) (802) and an ion extractor (804). The plasma source is adapted to generate ions and the ion extractor is immersed in the plasma source to extract a fraction...... of the generated ions. The ion extractor is surrounded by a space charge (810) formed at least in part by the extracted ions. The ion extractor includes a biased electrode (806) forming an interface with an insulator (808). The interface is customized to form a strongly curved potential distribution (812......) in the space-charge surrounding the ion extractor. The strongly curved potential distribution focuses the extracted ions towards an opening (814) on a surface of the biased electrode thereby resulting in an ion beam....

  15. Eletrodo íon-seletivo para determinação potenciométrica de alumínio(III em meio de fluoreto Ion-selective electrode for potentiometric determination of aluminium(III in fluoride medium

    Directory of Open Access Journals (Sweden)

    Evandro Piccin

    2004-12-01

    Full Text Available The construction and analytical evaluation of a coated graphite Al(III ion-selective electrode, based on the ionic pair formed between the Al(Fn3-n anion and tricaprylylmethylammonium cation (Aliquat 336S incorporated on a poly(vinylchloride (PVC matrix membrane are described. A thin membrane film of this ionic pair and dibutylphthalate (DBPh in PVC was deposited directly on a cylindric graphite rod (2 cm length x 0.5 cm diameter attached to the end of a glass tube using epoxy resin. The membrane solution was prepared by dissolving 40% (m/m of PVC in 10 mL of tetrahydrofuran following addition of 45% (m/m of DBPh and 15% (m/m of the ionic pair. The effect of membrane composition, fluoride concentration, and several concomitants as potential interferences on the electrode response were investigated. The aluminium(III ion-selective electrode showed a linear response ranging from 1.4 x 10-4 to 1.0 x 10-2 mol L-1, a detection limit of 4.0 x 10-5 mol L-1, aslope of -54.3±0.2mV dec-1 and a lifetime of more than 1 year (over 3000 determinations for each membrane. The slope indicates that the ion-selective electrode responds preferentially to the Al(F4- species. Application of this electrode for the aluminium(III determination in stomach anti-acid samples is reported.

  16. Experimental study of para- and ortho-H3+ recombination

    International Nuclear Information System (INIS)

    Plasil, R; Varju, J; Hejduk, M; Dohnal, P; KotrIk, T; Glosik, J

    2011-01-01

    Recombination of H 3 + with electrons is a key process for many plasmatic environments. Recent experiments on storage ring devices used ion sources producing H 3 + with enhanced populations of H 3 + ions in the para nuclear spin configuration to shed light on the theoretically predicted faster recombination of para states. Although increased recombination rates were observed, no in situ characterization of recombining ions was performed. We present a state selective recombination study of para- and ortho-H 3 + ions with electrons at 77 K in afterglow plasma in a He/Ar/H 2 gas-mixture. Both spin configurations of H 3 + have been observed in situ with a near infrared cavity ring down spectrometer (NIR-CRDS) using the two lowest energy levels of H 3 + . Using hydrogen with an enhanced population of H 2 molecules in para states allowed us to influence the [para-H 3 + ]/[ortho-H 3 + ] ratio in the discharge and in the afterglow. We observed an increase in the measured effective recombination rate coefficients with the increase of the fraction of para-H 3 + . Measurements with different fractions of para-H 3 + at otherwise identical conditions allowed us to determine the binary recombination rate coefficients for pure para-H 3 + p α bin (77 K) = (2.0±0.4)x10 -7 cm 3 s -1 and pure ortho-H 3 + o α bin (77 K) = (4±3)x10 -8 cm 3 s -1 .

  17. Heavy ions

    CERN Multimedia

    CERN. Geneva. Audiovisual Unit

    2002-01-01

    Colliding two heavy nuclei at ultrarelativistic energies allows to create in the laboratory a bulk system with huge density, pressure and temperature and to study its properties. It is estimated that in Pb-Pb collisions at CERN-SPS we reach over an appreciable volume an energy density which exceeds by more than a factor 20 that of normal nuclear matter. At such densities, the hadrons are so closely packed that they interpenetrate; novel physics phenomena are expected to appear. QCD predicts that under such conditions a phase transition from a system composed of colourless hadrons to a Quark-Gluon Plasma (QGP) should occur. A rich ultrarelativistic heavy-ion physics programme is under way both at BNL-AGS and at CERN-SPS since 1986. The results obtained so far have led CERN to officially announce evidence for a new state of matter last year. A long-range programme of heavy-ion physics at higher energies is under way (BNL-RHIC) and in preparation (CERN-LHC). These lectures are meant as an introduction to the phy...

  18. Heavy ions

    CERN Multimedia

    CERN. Geneva; Antinori, Federico

    2001-01-01

    Colliding two heavy nuclei at ultrarelativistic energies allows to create in the laboratory a bulk system with huge density, pressure and temperature and to study its properties. It is estimated that in Pb-Pb collisions at CERN-SPS we reach over an appreciable volume an energy density which exceeds by more than a factor 20 that of normal nuclear matter. At such densities, the hadrons are so closely packed that they interpenetrate; novel physics phenomena are expected to appear. QCD predicts that under such conditions a phase transition from a system composed of colourless hadrons to a Quark-Gluon Plasma (QGP) should occur. A rich ultrarelativistic heavy-ion physics programme is under way both at BNL-AGS and at CERN-SPS since 1986. The results obtained so far have led CERN to officially announce evidence for a new state of matter last year. A long-range programme of heavy-ion physics at higher energies is under way (BNL-RHIC) and in preparation (CERN-LHC). These lectures are meant as an introduction to the phy...

  19. ION GUN

    Science.gov (United States)

    Dandl, R.A.

    1961-10-24

    An ion gun is described for the production of an electrically neutral ionized plasma. The ion gun comprises an anode and a cathode mounted in concentric relationship with a narrow annulus between. The facing surfaces of the rear portions of the anode and cathode are recessed to form an annular manifold. Positioned within this manifold is an annular intermediate electrode aligned with the an nulus between the anode and cathode. Gas is fed to the manifold and an arc discharge is established between the anode and cathode. The gas is then withdrawn from the manifold through the annulus between the anode and cathode by a pressure differential. The gas is then ionized by the arc discharge across the annulus. The ionized gas is withdrawn from the annulus by the combined effects of the pressure differential and a collimating magnetic field. In a 3000 gauss magnetic field, an arc voltage of 1800 volts, and an arc current of 0.2 amp, a plasma of about 3 x 10/sup 11/ particles/cc is obtained. (AEC)

  20. Comparison between Electronic Portal Imaging Devices and ion chamber matrix for intensity-modulated radiotherapy quality assurance; Comparacao entre Dispositivos Eletronicos de Imagens Portais e matriz de camaras de ionizacao para garantia da qualidade de radioterapia de intensidade modulada

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Thiago B.; Rosa, Luiz A.R., E-mail: thiago.fisimed@gmail.com [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Lima, Marilia B., E-mail: thiago.fisimed@gmail.com [Instituto Nacional do Cancer (INCA), Rio de Janeiro, RJ (Brazil). Departamento de Fisica Medica

    2012-08-15

    The treatment with intensity-modulated radiotherapy (IMRT) demands an individual and specific quality assurance procedure. The use of ion chamber matrix is a well establish method to dose distribution verifications, despite the lower spatial resolution. An alternative method arising is the use of the Electronic Portal Imaging Devices (EPIDs). The aim of this paper is to validate the EPID use for quality assurance of IMRT comparing it to the previous method employing an ion chamber matrix. We analyzed 10 treatment planning for different tumor sites and photons energies of the linac Trilogy (Varian Medical Systems). We used Sliding-window IMRT and the measurements were acquired in EPID and in Physikalisch-Technische Werkstaetten (PTW) 2D Array seven29. Two different software were used to analyze the data: Verisoft version 4.0, for Array data; and Eclipse 8.6 with Portal Dosimetry for EPID data. The evaluation of concordance levels between measured and predicted images used the Gamma Index tool with 3% of dose difference and 3 mm of distance to agreement. The EPID showed worse results for approval percentiles, in average 2.17%, and bigger values of average gamma index, although its analysis confirmed the approvals of all planning. This happens because of the better sensitivity generated by the higher spatial resolution of the EPID, 0,784 mm against 1,0 cm of the Array, so it has bigger capacity to identify small dose variations. The EPID, jointly with the Portal Dosimetry, proved to be excellent tools to perform pre-treatment IMRT verifications, providing significant gain in dose distribution analysis. Also, the EPID is easier for positioning, for images manipulation, for data acquisition and analysis and has detection area 60% bigger. (author)

  1. para palmito

    Directory of Open Access Journals (Sweden)

    Francisco Paulo Chaimsohn

    2007-01-01

    Full Text Available Densidades de siembra, arreglos espaciales y fertilización en pejibaye (Bactris gasipaes cv Diamantes-10 para palmito. La investigación se llevó a cabo en la Estación Experimental Los Diamantes (Guápiles, Costa Rica, el 3 de octubre del 2003, cuyo objetivo fue la evaluación del efecto de diferentes densidades de siembra (3.333, 5.000 y 6.666 plantas/ha, arreglos espaciales, y diversos métodos de fertilización (química, orgánica, sobre el crecimiento de las plantas de pejibaye para producción de palmito. Se consideraron las variables diámetro y altura del tallo primario y el número de hojas y rebrotes como indicadores de producción. El período de evolución abarcó sólo los primeros 25 meses de crecimiento en el campo. El número de hojas, la altura y el diámetro del tallo no mostraron diferencias de respuesta relevantes. Sólo el número de rebrotes disminuyó al aumentar la densidad de la población, cuando se midió a los 15 meses de edad. El efecto de la fertilización se hizo evidente después de la primera cosecha, realizada a los 20 meses, debido al aumento de la competencia entre plantas, ahora más desarrolladas. Fue entonces cuando la fertilización química indujo la producción de un mayor número y vigor de los rebrotes. Sin embargo, las prácticas evaluadas 25 meses después de la siembra, no habían infl uido hasta ese momento en el número de palmitos cosechados, ni tampoco había afectado las características físicas de los sectores foliar y caulinar del palmito.

  2. Ion beam monitoring

    International Nuclear Information System (INIS)

    McKinney, C.R.

    1980-01-01

    An ion beam analyzer is specified, having an ion source for generating ions of a sample to be analyzed, means for extracting the sample ions, means for focusing the sample ions into a beam, separation means positioned along the ion beam for selectively deflecting species of ions, and means for detecting the selected species of ions. According to the specification, the analyzer further comprises (a) means for disabling at least a portion of the separation means, such that the ion beam from the source remains undeflected; (b) means located along the path of the undeflected ion beam for sensing the sample ions; and (c) enabling means responsive to the sensing means for automatically re-enabling the separation means when the sample ions reach a predetermined intensity level. (author)

  3. Ion funnel ion trap and process

    Science.gov (United States)

    Belov, Mikhail E [Richland, WA; Ibrahim, Yehia M [Richland, WA; Clowers, Biran H [West Richland, WA; Prior, David C [Hermiston, OR; Smith, Richard D [Richland, WA

    2011-02-15

    An ion funnel trap is described that includes a inlet portion, a trapping portion, and a outlet portion that couples, in normal operation, with an ion funnel. The ion trap operates efficiently at a pressure of .about.1 Torr and provides for: 1) removal of low mass-to-charge (m/z) ion species, 2) ion accumulation efficiency of up to 80%, 3) charge capacity of .about.10,000,000 elementary charges, 4) ion ejection time of 40 to 200 .mu.s, and 5) optimized variable ion accumulation times. Ion accumulation with low concentration peptide mixtures has shown an increase in analyte signal-to-noise ratios (SNR) of a factor of 30, and a greater than 10-fold improvement in SNR for multiply charged analytes.

  4. Experimental method for calculation of effective doses in interventional radiology; Metodo experimental para calculo de dosis efectivas en radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Herraiz Lblanca, M. D.; Diaz Romero, F.; Casares Magaz, O.; Garrido Breton, C.; Catalan Acosta, A.; Hernandez Armas, J.

    2013-07-01

    This paper proposes a method that allows you to calculate the effective dose in any interventional radiology procedure using an anthropomorphic mannequin Alderson RANDO and dosimeters TLD 100 chip. This method has been applied to an angio Radiology procedure: the biliary drainage. The objectives that have been proposed are: to) put together a method that, on an experimental basis, allows to know dosis en organs to calculate effective dose in complex procedures and b) apply the method to the calculation of the effective dose of biliary drainage. (Author)

  5. Aditivos (ionóforos, antibióticos não ionóforos e probióticos) em dietas com altos teores de concentrado para tourinhos da raça Nelore em terminação

    OpenAIRE

    Cristiane Sitta

    2011-01-01

    Foram conduzidos dois experimentos no confinamento experimental do Departamento de Zootecnia da ESALQ/USP com o objetivo de estudar os efeitos de diferentes aditivos em dietas para bovinos terminados em confinamento. As dietas continham 78,1% de milho moído fino, 12% feno de Tifton-85, 6% melaço de cana, 2,5% mineral, 1,4% uréia e os respectivos aditivos. No experimento 1 foram utilizados 134 tourinhos da raça Nelore com 24 meses de idade e 330 kg de peso corporal médio inicial, alocados em 2...

  6. Materiais cerâmicos ferroelétricos como hospedeiros para íons laser ativos: características estruturais, microestruturais e espectroscópicas Ferroelectric ceramic materials as hosts of laser active ions: structural, microstructural and spectroscopic characteristics

    Directory of Open Access Journals (Sweden)

    A. S. S. de Camargo

    2004-12-01

    Full Text Available Cerâmicas ferroelétricas transparentes de titanato zirconato de chumbo modificado com lantânio (PLZT, com La/Zr/Ti=9/65/35 e dopadas com íons terras raras (TR = Nd3+, Er3+, Yb3+, Tm3+ e Ho3+ foram preparadas por prensagem uniaxial a quente com o objetivo de investigar a sua qualificação como materiais laser ativos. Com este propósito foram feitas caracterizações estruturais, microestruturais, elétricas e espectroscópicas. Para a dopagem com 1% em peso de óxido TR2O3, verificou-se uma forte influência do tipo de íon terra rara nas características ferroelétricas e óticas do material hospedeiro. Observou-se ainda que a incorporação de Nd3+ nos sítios de Pb2+/La3+ reduziu a temperatura de transição ferro-paraelétrica e favoreceu significativamente a transparência dos corpos cerâmicos. Medidas de espectroscopia ótica revelaram a potencialidade do PLZT: Nd3+ como um meio ativo para a construção de lasers bombeados por lasers de diodo, na região do infravermelho próximo. Os sistemas PLZT:Er3+ e PLZT:Tm3+ poderão também se tornar materiais interessantes para esse fim.In this work, transparent ferroelectric ceramics of lanthanum modified lead zirconate titanate (PLZT, with La/Zr/Ti=9/65/35, doped with rare-earth ions (RE = Nd3+, Er3+, Yb3+ Tm3+ and Ho3+, were processed by hot uniaxial pressing aiming the investigation of their potentiality as near-infrared laser active media. Their structural, microstructural, electric and spectroscopic characterizations were performed. For 1.0 wt.% RE2O3 doping, a strong influence of the rare-earth type was verified in the PLZT ferroelectric and optical characteristics. It was also observed that the Nd3+ substitution for Pb2+/La3+ reduces the ferro-paraelectric phase transition temperature and favors the transparency of the ceramic bodies. Spectroscopic analysis indicates that PLZT:Nd3+ is a potential diode-pumped laser active media in the near infrared region, and with some improvements

  7. Gas phase ion chemistry

    CERN Document Server

    Bowers, Michael T

    1979-01-01

    Gas Phase Ion Chemistry, Volume 1 covers papers on the advances of gas phase ion chemistry. The book discusses the advances in flow tubes and the measurement of ion-molecule rate coefficients and product distributions; the ion chemistry of the earth's atmosphere; and the classical ion-molecule collision theory. The text also describes statistical methods in reaction dynamics; the state selection by photoion-photoelectron coincidence; and the effects of temperature and pressure in the kinetics of ion-molecule reactions. The energy distribution in the unimolecular decomposition of ions, as well

  8. Microfabricated ion frequency standard

    Science.gov (United States)

    Schwindt, Peter; Biedermann, Grant; Blain, Matthew G.; Stick, Daniel L.; Serkland, Darwin K.; Olsson, III, Roy H.

    2010-12-28

    A microfabricated ion frequency standard (i.e. an ion clock) is disclosed with a permanently-sealed vacuum package containing a source of ytterbium (Yb) ions and an octupole ion trap. The source of Yb ions is a micro-hotplate which generates Yb atoms which are then ionized by a ultraviolet light-emitting diode or a field-emission electron source. The octupole ion trap, which confines the Yb ions, is formed from suspended electrodes on a number of stacked-up substrates. A microwave source excites a ground-state transition frequency of the Yb ions, with a frequency-doubled vertical-external-cavity laser (VECSEL) then exciting the Yb ions up to an excited state to produce fluorescent light which is used to tune the microwave source to the ground-state transition frequency, with the microwave source providing a precise frequency output for the ion clock.

  9. Komputasi Data Isotermal Reaksi Pertukaran Ion

    Directory of Open Access Journals (Sweden)

    Sumarbagiono Sumarbagiono

    2017-03-01

    Full Text Available Sebagian besar data penelitian yang masih bersifat teknis perlu dievaluasi lebih lanjut denganmenggunakan metode komputasi Data Isotermal Reaksi Pertukaran Ion dalam proses penyerapanlogam berat dan radionukleotida oleh material sorben dari limbah cair. Melalui perhitungan KonstantaKesetimbangan (Ka dan Kuotisi Kielland diperoleh nilai entropi dan entalpi yang dapat digunakanuntuk mengetahui selektifitas unsur yang teradsorsi dalam zeolit. Program Kielland denganmenggunakan Delphi 5 dapat digunakan secara praktis oleh para peneliti untuk menganalisa dataisothermal pertukaran ion dari reaksi kesetimbangan dengan menghasilkan data yang lebih baik.

  10. Negative ion sources

    International Nuclear Information System (INIS)

    Ishikawa, Junzo; Takagi, Toshinori

    1983-01-01

    Negative ion sources have been originally developed at the request of tandem electrostatic accelerators, and hundreds of nA to several μA negative ion current has been obtained so far for various elements. Recently, the development of large current hydrogen negative ion sources has been demanded from the standpoint of the heating by neutral particle beam injection in nuclear fusion reactors. On the other hand, the physical properties of negative ions are interesting in the thin film formation using ions. Anyway, it is the present status that the mechanism of negative ion action has not been so fully investigated as positive ions because the history of negative ion sources is short. In this report, the many mechanisms about the generation of negative ions proposed so far are described about negative ion generating mechanism, negative ion source plasma, and negative ion generation on metal surfaces. As a result, negative ion sources are roughly divided into two schemes, plasma extraction and secondary ion extraction, and the former is further classified into the PIG ion source and its variation and Duoplasmatron and its variation; while the latter into reflecting and sputtering types. In the second half of the report, the practical negative ion sources of each scheme are described. If the mechanism of negative ion generation will be investigated more in detail and the development will be continued under the unified know-how as negative ion sources in future, the development of negative ion sources with which large current can be obtained for any element is expected. (Wakatsuki, Y.)

  11. Electron Beam Ion Sources

    CERN Document Server

    Zschornacka, G.; Thorn, A.

    2013-12-16

    Electron beam ion sources (EBISs) are ion sources that work based on the principle of electron impact ionization, allowing the production of very highly charged ions. The ions produced can be extracted as a DC ion beam as well as ion pulses of different time structures. In comparison to most of the other known ion sources, EBISs feature ion beams with very good beam emittances and a low energy spread. Furthermore, EBISs are excellent sources of photons (X-rays, ultraviolet, extreme ultraviolet, visible light) from highly charged ions. This chapter gives an overview of EBIS physics, the principle of operation, and the known technical solutions. Using examples, the performance of EBISs as well as their applications in various fields of basic research, technology and medicine are discussed.

  12. Proposal of a postal system for Ir-192 sources calibration used in high dose rate brachytherapy with LiF:Mn:Ti thermoluminescent dosemeters; Proposta de um sistema postal para a calibracao de fontes de {sup 192} Ir, utilizadas em braquiterapia de alta taxa de dose, com dosimetros termoluminescentes de LiF: Mn: Ti

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, W.S.; Borges, J.C.; Almeida, C.E.V. [Instituto de Radioprotecao e Dosimetria. CNEN Caixa Postal 37750, 22780-160, Rio de Janeiro (Brazil)

    1998-12-31

    A proposal in order to improve the brachytherapy quality control and to allow postal intercomparison of Ir-192 sources used in high dose rate brachytherapy has been presented. The LiF: Mn: Ti (TLD 100) detector has been selected for such purpose. The experimental array and the TLDs irradiation and calibration techniques, at the treatment units, have been specified in the light of more recent methodology of Ir-192 calibration sources. (Author)

  13. Radioactive Ion Sources

    CERN Document Server

    Stora, T

    2013-01-01

    This chapter provides an overview of the basic requirements for ion sources designed and operated in radioactive ion beam facilities. The facilities where these sources are operated exploit the isotope separation online (ISOL) technique, in which a target is combined with an ion source to maximize the secondary beam intensity and chemical element selectivity. Three main classes of sources are operated, namely surface-type ion sources, arc discharge-type ion sources, and finally radio-frequency-heated plasma-type ion sources.

  14. Ions and light

    CERN Document Server

    Bowers, Michael T

    2013-01-01

    Gas Phase Ion Chemistry, Volume 3: Ions and Light discusses how ions are formed by electron impact, ion-molecule reactions, or electrical discharge. This book discusses the use of light emitted by excited molecules to characterize either the chemistry that formed the excited ion, the structure of the excited ion, or both.Organized into 10 chapters, this volume begins with an overview of the extension of the classical flowing afterglow technique to include infrared and chemiluminescence and laser-induced fluorescence detection. This text then examines the experiments involving molecules that ar

  15. Experimental study of para- and ortho-H3+ recombination

    Science.gov (United States)

    Plašil, R.; Varju, J.; Hejduk, M.; Dohnal, P.; Kotrík, T.; Glosík, J.

    2011-07-01

    Recombination of H3+ with electrons is a key process for many plasmatic environments. Recent experiments on storage ring devices used ion sources producing H3+ with enhanced populations of H3+ ions in the para nuclear spin configuration to shed light on the theoretically predicted faster recombination of para states. Although increased recombination rates were observed, no in situ characterization of recombining ions was performed. We present a state selective recombination study of para- and ortho-H3+ ions with electrons at 77 K in afterglow plasma in a He/Ar/H2 gas-mixture. Both spin configurations of H3+ have been observed in situ with a near infrared cavity ring down spectrometer (NIR-CRDS) using the two lowest energy levels of H3+. Using hydrogen with an enhanced population of H2 molecules in para states allowed us to influence the [para-H3+]/[ortho-H3+] ratio in the discharge and in the afterglow. We observed an increase in the measured effective recombination rate coefficients with the increase of the fraction of para-H3+. Measurements with different fractions of para-H3+ at otherwise identical conditions allowed us to determine the binary recombination rate coefficients for pure para-H3+ pαbin(77 K) = (2.0±0.4)×10-7 cm3s-1 and pure ortho-H3+ oαbin(77 K) = (4±3)×10-8 cm3s-1.

  16. Single Cathode Ion Thruster

    Data.gov (United States)

    National Aeronautics and Space Administration — Objective is to design an electrostatic ion thruster that is more efficient, simpler, and lower cost than the current gridded ion thruster. Initial objective is to...

  17. Applications of decelerated ions

    International Nuclear Information System (INIS)

    Johnson, B.M.

    1985-03-01

    Many facilities whose sole purpose had been to accelerate ion beams are now becoming decelerators as well. The development and current status of accel-decel operations is reviewed here. Applications of decelerated ions in atomic physics experiments are discussed

  18. Gas phase ion chemistry

    CERN Document Server

    Bowers, Michael T

    1979-01-01

    Gas Phase Ion Chemistry, Volume 2 covers the advances in gas phase ion chemistry. The book discusses the stabilities of positive ions from equilibrium gas-phase basicity measurements; the experimental methods used to determine molecular electron affinities, specifically photoelectron spectroscopy, photodetachment spectroscopy, charge transfer, and collisional ionization; and the gas-phase acidity scale. The text also describes the basis of the technique of chemical ionization mass spectrometry; the energetics and mechanisms of unimolecular reactions of positive ions; and the photodissociation

  19. Ion mobility spectrometry

    CERN Document Server

    Eiceman, GA

    2005-01-01

    Key Developments for Faster, More Precise Detection Capabilities Driven by the demand for the rapid and advanced detection of explosives, chemical and biological warfare agents, and narcotics, ion mobility spectrometry (IMS) undergone significant refinements in technology, computational capabilities, and understanding of the principles of gas phase ion chemistry and mobility. Beginning with a thorough discussion of the fundamental theories and physics of ion mobility, Ion Mobility Spectrometry, Second Edition describes the recent advances in instrumentation and newly

  20. Negative Ion Density Fronts

    International Nuclear Information System (INIS)

    Igor Kaganovich

    2000-01-01

    Negative ions tend to stratify in electronegative plasmas with hot electrons (electron temperature Te much larger than ion temperature Ti, Te > Ti ). The boundary separating a plasma containing negative ions, and a plasma, without negative ions, is usually thin, so that the negative ion density falls rapidly to zero-forming a negative ion density front. We review theoretical, experimental and numerical results giving the spatio-temporal evolution of negative ion density fronts during plasma ignition, the steady state, and extinction (afterglow). During plasma ignition, negative ion fronts are the result of the break of smooth plasma density profiles during nonlinear convection. In a steady-state plasma, the fronts are boundary layers with steepening of ion density profiles due to nonlinear convection also. But during plasma extinction, the ion fronts are of a completely different nature. Negative ions diffuse freely in the plasma core (no convection), whereas the negative ion front propagates towards the chamber walls with a nearly constant velocity. The concept of fronts turns out to be very effective in analysis of plasma density profile evolution in strongly non-isothermal plasmas

  1. Enhanced ion acoustic fluctuations and ion outflows

    Directory of Open Access Journals (Sweden)

    F. R. E. Forme

    1999-02-01

    Full Text Available A number of observations showing enhanced ion acoustic echoes observed by means of incoherent scatter radars have been reported in the literature. The received power is extremely enhanced by up to 1 or 2 orders of magnitude above usual values, and it is mostly contained in one of the two ion acoustic lines. This spectral asymmetry and the intensity of the received signal cannot be resolved by the standard analysis procedure and often causes its failure. As a result, and in spite of a very clear spectral signature, the analysis is unable to fit the plasma parameters inside the regions of ion acoustic turbulence. We present European Incoherent Scatter radar (EISCAT observations of large ion outflows associated with the simultaneous occurrence of enhanced ion acoustic echoes. The ion fluxes can reach 1014 m-2 s-1 at 800 km altitude. From the very clear spectral signatures of these echoes, a method is presented to extract estimates of the electron temperature and the ion drift within the turbulent regions. It is shown that the electron gas is strongly heated up to 11 000 K. Also electron temperature gradients of about 0.02 K/m exist. Finally, the estimates of the electron temperature and of the ion drift are used to study the possible implications for the plasma transport inside turbulent regions. It is shown that strong electron temperature gradients cause enhancement of the ambipolar electric field and can account for the observed ion outflows.Key words. Ionosphere (auroral ionosphere; ionosphere · magnetosphere interactions; plasma waves and instabilities.

  2. Multicharged ion sources

    International Nuclear Information System (INIS)

    Venikov, N.I.

    1979-01-01

    The main principles of action, beam parameters, basic problems and prospects for development of the available multicharged ion sources for various types of accelerators are considered. Descriptions of three types of Penneng sources (a source with coid cathodes, direct-heated source, and a source with a heated cathode), duoplasmatron, SHP source using electron-cyclotron resonance, electron-ray and laser sources are given. The problems productions for solid substance ions, lithium and beryllium ions in Penning sources, are considered as well as the problem of ion charge growth on passage of accelerated ion/or atom beam through a stripping target [ru

  3. Vacuum Arc Ion Sources

    CERN Document Server

    Brown, I.

    2013-12-16

    The vacuum arc ion source has evolved into a more or less standard laboratory tool for the production of high-current beams of metal ions, and is now used in a number of different embodiments at many laboratories around the world. Applications include primarily ion implantation for material surface modification research, and good performance has been obtained for the injection of high-current beams of heavy-metal ions, in particular uranium, into particle accelerators. As the use of the source has grown, so also have the operational characteristics been improved in a variety of different ways. Here we review the principles, design, and performance of vacuum arc ion sources.

  4. Quantitative ion implantation

    International Nuclear Information System (INIS)

    Gries, W.H.

    1976-06-01

    This is a report of the study of the implantation of heavy ions at medium keV-energies into electrically conducting mono-elemental solids, at ion doses too small to cause significant loss of the implanted ions by resputtering. The study has been undertaken to investigate the possibility of accurate portioning of matter in submicrogram quantities, with some specific applications in mind. The problem is extensively investigated both on a theoretical level and in practice. A mathematical model is developed for calculating the loss of implanted ions by resputtering as a function of the implanted ion dose and the sputtering yield. Numerical data are produced therefrom which permit a good order-of-magnitude estimate of the loss for any ion/solid combination in which the ions are heavier than the solid atoms, and for any ion energy from 10 to 300 keV. The implanted ion dose is measured by integration of the ion beam current, and equipment and techniques are described which make possible the accurate integration of an ion current in an electromagnetic isotope separator. The methods are applied to two sample cases, one being a stable isotope, the other a radioisotope. In both cases independent methods are used to show that the implantation is indeed quantitative, as predicted. At the same time the sample cases are used to demonstrate two possible applications for quantitative ion implantation, viz. firstly for the manufacture of calibration standards for instrumental micromethods of elemental trace analysis in metals, and secondly for the determination of the half-lives of long-lived radioisotopes by a specific activity method. It is concluded that the present study has advanced quantitative ion implantation to the state where it can be successfully applied to the solution of problems in other fields

  5. Atomic ion clock with two ion traps, and method to transfer ions

    Science.gov (United States)

    Prestage, John D. (Inventor); Chung, Sang K. (Inventor)

    2011-01-01

    An atomic ion clock with a first ion trap and a second ion trap, where the second ion trap is of higher order than the first ion trap. In one embodiment, ions may be shuttled back and forth from one ion trap to the other by application of voltage ramps to the electrodes in the ion traps, where microwave interrogation takes place when the ions are in the second ion trap, and fluorescence is induced and measured when the ions are in the first ion trap. In one embodiment, the RF voltages applied to the second ion trap to contain the ions are at a higher frequency than that applied to the first ion trap. Other embodiments are described and claimed.

  6. Ion photon emission microscope

    Science.gov (United States)

    Doyle, Barney L.

    2003-04-22

    An ion beam analysis system that creates microscopic multidimensional image maps of the effects of high energy ions from an unfocussed source upon a sample by correlating the exact entry point of an ion into a sample by projection imaging of the ion-induced photons emitted at that point with a signal from a detector that measures the interaction of that ion within the sample. The emitted photons are collected in the lens system of a conventional optical microscope, and projected on the image plane of a high resolution single photon position sensitive detector. Position signals from this photon detector are then correlated in time with electrical effects, including the malfunction of digital circuits, detected within the sample that were caused by the individual ion that created these photons initially.

  7. The TL fluence response to heavy charged particles using the track interaction model and track structure information

    International Nuclear Information System (INIS)

    Rodriguez-Villafuerte, M.; Avila, O.

    2002-01-01

    The extended track interaction model, ETIM, has recently been proposed to explain the TLD-100 fluence response of peak 5 to heavy ions. This model includes the track structure information through the use of the luminescent-centre occupation probability obtained from radial dose distributions produced by the ions as they travel through the dosemeter. In this work an implementation of ETIM using Monte Carlo techniques is presented. The simulation was applied to calculate the response of peak 5 of both sensitised and normal TLD-100 crystals to 2.6 and 6.8 MeV 4 He ions. The simulation shows that the TL-fluence response has a strong dependence on ion energy, in disagreement with experimental observations. In spite of this, good agreement between the simulated TL-fluence response calculated for the 6.8 MeV 4 He radial distributions and the experimental data for the two energies was achieved. (author)

  8. Ion implantation in metals

    International Nuclear Information System (INIS)

    Vook, F.L.

    1977-02-01

    The application of ion beams to metals is rapidly emerging as a promising area of research and technology. This report briefly describes some of the recent advances in the modification and study of the basic properties of metals by ion implantation techniques. Most of the research discussed illustrates some of the new and exciting applications of ion beams to metals which are under active investigation at Sandia Laboratories, Albuquerque

  9. Ion Trap Quantum Computing

    Science.gov (United States)

    2011-12-01

    stored ions,” Adv. Atom Mol. Phys., vol. Volume 3, pp. 53–72 1968. [48] P. H. Dawson, Quadrupole Mass Spectometry and Its Applications, Melville, NY... DATE December 2011 3. REPORT TYPE AND DATES COVERED Master’s Thesis 4. TITLE AND SUBTITLE Ion trap Quantum Computing 5. FUNDING NUMBERS 6...researcher [30] that introduced the concept of ion traps in the 1950s. His experiments focused on separating atoms with different masses in order to

  10. Neutron ion temperature measurement

    International Nuclear Information System (INIS)

    Strachan, J.D.; Hendel, H.W.; Lovberg, J.; Nieschmidt, E.B.

    1986-11-01

    One important use of fusion product diagnostics is in the determination of the deuterium ion temperature from the magnitude of the 2.5 MeV d(d,n) 3 He neutron emission. The detectors, calibration methods, and limitations of this technique are reviewed here with emphasis on procedures used at PPPL. In most tokamaks, the ion temperature deduced from neutrons is in reasonable agreement with the ion temperature deduced by other techniques

  11. Lithium-ion batteries

    CERN Document Server

    Yoshio, Masaki; Kozawa, Akiya

    2010-01-01

    This book is a compilation of up-to-date information relative to Li-Ion technology. It provides the reader with a single source covering all important aspects of Li-Ion battery operations. It fills the gap between the old original Li-Ion technology and present state of the technology that has developed into a high state of practice. The book is designed to provide a single source for an up-to-date description of the technology associated with the Li-Ion battery industry. It will be useful to researchers interested in energy conversion for the direct conversion of chemical energy into electrica

  12. Dynamic ion implantation

    International Nuclear Information System (INIS)

    Oppenheim, I.F.C.

    1988-01-01

    The Dynamic Ion Implantation Technique consists of ion implantation of a film during the film-deposition process. This technique was investigated theoretically and experimentally with ions whose incident energy is of the order of a few times 100 keV. It was found to be a viable alternative low-temperature method for the preparation of thick zirconium nitride films (∼1 μm) with good mechanical properties. Theoretical modeling of the processes involved during dynamic ion implantation lead to analytical expressions for the ions' depth-profile distributions. Numerical evaluations of these equations indicated that the depth distributions of dynamically implanted ions are in general more uniform than those predicted by the model for ions implanted by more conventional techniques. Mechanical properties of stoichiometric RF sputter-deposited zirconium nitride films post implanted with krypton and rubidium ions were investigated. Scratch-adhesion critical load and Vickers microhardness of samples implanted with doses varying from 1 x 10 15 to 5 x 10 16 ions/cm 2 and energies ranging from 300 to 500 keV were studied. In general, best mechanical properties were observed for 300- keV krypton implantations

  13. Correlation ion mobility spectroscopy

    Science.gov (United States)

    Pfeifer, Kent B [Los Lunas, NM; Rohde, Steven B [Corrales, NM

    2008-08-26

    Correlation ion mobility spectrometry (CIMS) uses gating modulation and correlation signal processing to improve IMS instrument performance. Closely spaced ion peaks can be resolved by adding discriminating codes to the gate and matched filtering for the received ion current signal, thereby improving sensitivity and resolution of an ion mobility spectrometer. CIMS can be used to improve the signal-to-noise ratio even for transient chemical samples. CIMS is especially advantageous for small geometry IMS drift tubes that can otherwise have poor resolution due to their small size.

  14. Doppler ion program description

    International Nuclear Information System (INIS)

    Henline, P.

    1980-12-01

    The Doppler spectrometer is a conventional Czerny-Turner grating spectrometer with a 1024 channel multiple detector. Light is dispersed across the detector, and its output yields a spectrum covering approximately 200 A. The width of the spectral peak is directly proportional to the temperature of the emitting ions, and determination of the impurity ion temperature allows one to infer the plasma ion temperature. The Doppler ion software system developed at General Atomic uses a TRACOR Northern 1710-31 and an LSI-11/2. The exact configuration of Doublet III is different from TRACOR Northern systems at other facilities

  15. Subvenciones para instituciones

    International Development Research Centre (IDRC) Digital Library (Canada)

    IDRC CRDI

    Subvenciones para instituciones Directrices para gastos de proyectos aceptables. GFAPE-09-2015. 2 ... más de 5.000 CAD. Los costos pueden incluir el precio base de compra, costos de transporte y otros ... personas que recogen datos e información o que trabajan de manera eventual, el mantenimiento y la operación de ...

  16. High current ion sources

    International Nuclear Information System (INIS)

    Brown, I.G.

    1989-06-01

    The concept of high current ion source is both relative and evolutionary. Within the domain of one particular kind of ion source technology a current of microamperers might be 'high', while in another area a current of 10 Amperes could 'low'. Even within the domain of a single ion source type, what is considered high current performance today is routinely eclipsed by better performance and higher current output within a short period of time. Within their fields of application, there is a large number of kinds of ion sources that can justifiably be called high current. Thus, as a very limited example only, PIGs, Freemen sources, ECR sources, duoplasmatrons, field emission sources, and a great many more all have their high current variants. High current ion beams of gaseous and metallic species can be generated in a number of different ways. Ion sources of the kind developed at various laboratories around the world for the production of intense neutral beams for controlled fusion experiments are used to form large area proton deuteron beams of may tens of Amperes, and this technology can be used for other applications also. There has been significant progress in recent years in the use of microwave ion sources for high current ion beam generation, and this method is likely to find wide application in various different field application. Finally, high current beams of metal ions can be produced using metal vapor vacuum arc ion source technology. After a brief consideration of high current ion source design concepts, these three particular methods are reviewed in this paper

  17. Binary recombination of para- and ortho-H3+ with electrons at low temperatures.

    Science.gov (United States)

    Dohnal, P; Hejduk, M; Varju, J; Rubovic, P; Roucka, S; Kotrík, T; Plasil, R; Johnsen, R; Glosík, J

    2012-11-13

    Results of an experimental study of binary recombination of para- and ortho-H(3)(+) ions with electrons are presented. Near-infrared cavity-ring-down absorption spectroscopy was used to probe the lowest rotational states of H(3)(+) ions in the temperature range of 77-200 K in an H(3)(+)-dominated afterglow plasma. By changing the para/ortho abundance ratio, we were able to obtain the binary recombination rate coefficients for pure and para-H(3)(+) and ortho-H(3)(+). The results are in good agreement with previous theoretical predictions.

  18. Where do ions solvate?

    Indian Academy of Sciences (India)

    Abstract. We study a simple model of ionic solvation inside a water cluster. The cluster is modeled as a spherical dielectric continuum. It is found that unpolarizable ions always prefer the bulk solvation. On the other hand, for polarizable ions, there exists a critical value of polarization above which surface solvation becomes ...

  19. Ion-beam technologies

    Energy Technology Data Exchange (ETDEWEB)

    Fenske, G.R. [Argonne National Lab., IL (United States)

    1993-01-01

    This compilation of figures and diagrams reviews processes for depositing diamond/diamond-like carbon films. Processes addressed are chemical vapor deposition (HFCVD, PACVD, etc.), plasma vapor deposition (plasma sputtering, ion beam sputtering, evaporation, etc.), low-energy ion implantation, and hybrid processes (biased sputtering, IBAD, biased HFCVD, etc.). The tribological performance of coatings produced by different means is discussed.

  20. Quadrupole Ion Traps

    Indian Academy of Sciences (India)

    elimination of transit-time broadening making it possible to do precision spectroscopic measurements on these ions. Several important experiments with single electron or ion have been undertaken to address problems related to basic physics, such as the measurement of the electron radius, precision measurements of ...

  1. Ion implantation in ices

    International Nuclear Information System (INIS)

    Strazzulla, G.; Baratta, G.A.; Palumbo, M.E.; Satorre, M.A.

    2000-01-01

    We have studied, by in situ infrared spectroscopy, some effects due to ion implantation in frozen ices. In particular mixtures containing C, N and O atoms (e.g., N 2 :H 2 O:CH 4 ) have been irradiated with unreactive (noble gases) ions: the resulting alteration of the frozen sample induces the formation of other molecules (e.g., CO 2 , R- - -OCN, CO and HCN) and of a refractory organic residue. Similar products are formed when mixtures containing only C and O atoms (e.g., H 2 O:CH 4 ) are irradiated with N ions, i.e. molecular species that include the projectile are formed. These results are important, in particular for their applications to planetary physics. In planetary environments ice thickness is usually much larger than the penetration depth of the relevant ion populations (solar wind ions, magnetospheric particles, etc.) and ion implantation phenomena are expected. Our results indicate that some molecular species observed on icy planetary surfaces could not be native of that object but formed by ion irradiation and/or by implantation of reactive ions

  2. Accelerators for heavy ions

    International Nuclear Information System (INIS)

    Martin, J.A.

    1975-01-01

    The use of heavy ion accelerators in nuclear physics, nuclear chemistry, atomic physics, and in material sciences studies is rapidly increasing. A review is given of the present and developing scene in heavy ion accelerator concepts and technology. The area of applicability of various methods, likely avenues of future development, and the trends of future requirements are discussed. (auth)

  3. Ion beam studies

    International Nuclear Information System (INIS)

    Freeman, J.H.; Chivers, D.J.; Gard, G.A.; Temple, W.

    1977-04-01

    A description of techniques for the production of intense beams of heavy ions is given. A table of recommended operational procedures for most elements is included. The ionisation of boron is considered in some detail because of its particular importance as a dopant for ion implantation. (author)

  4. Cooperativity in ion hydration

    NARCIS (Netherlands)

    Tielrooij, K.J.; Garcia-Araez, N.; Bonn, M.; Bakker, H.J.

    2010-01-01

    Despite prolonged scientific efforts to unravel the effects of ions on the structure and dynamics of water, many open questions remain, in particular concerning the spatial extent of this effect (i.e., the number of water molecules affected) and the origin of ion-specific effects. A combined

  5. Future of ion machines

    International Nuclear Information System (INIS)

    Blaha, A.

    1975-01-01

    On the basis of a systematic arrangement of various types of ion machines according to their purpose, the corresponding characteristic functional parameters of the individual machines are derived. Atomic and nuclear ion machines are not dealt with. The common characteristics of this new type of machines are derived, namely the velocity of the beam, its formation capacity and interaction

  6. Quadrupole Ion Traps

    Indian Academy of Sciences (India)

    electron bound to the gravitational field, the 'geonium atom'. The first atomic hyperfine structure experiment on trapped ions was performed by Dehmelt's group using the stored-ion exchange-collision technique in a Paul trap which paved the way for some of the subsequent experiment for atomic frequency. A single atom at.

  7. Where do ions solvate?

    Indian Academy of Sciences (India)

    We study a simple model of ionic solvation inside a water cluster. The cluster is modeled as a spherical dielectric continuum. It is found that unpolarizable ions always prefer the bulk solvation. On the other hand, for polarizable ions, there exists a critical value of polarization above which surface solvation becomes ...

  8. Ion mobilities and ion-atom interaction potentials

    International Nuclear Information System (INIS)

    Gatland, I.R.

    1982-01-01

    The techniques for measuring the mobilities of ions in gases, relating interaction potentials to mobilities, and determining potentials from experimental mobilities are reviewed. Applications are presented for positive alkali ions and negative halogen ions in inert gases. (Auth.)

  9. Cryogenic surface ion traps

    International Nuclear Information System (INIS)

    Niedermayr, M.

    2015-01-01

    Microfabricated surface traps are a promising architecture to realize a scalable quantum computer based on trapped ions. In principle, hundreds or thousands of surface traps can be located on a single substrate in order to provide large arrays of interacting ions. To this end, trap designs and fabrication methods are required that provide scalable, stable and reproducible ion traps. This work presents a novel surface-trap design developed for cryogenic applications. Intrinsic silicon is used as the substrate material of the traps. The well-developed microfabrication and structuring methods of silicon are utilized to create simple and reproducible traps. The traps were tested and characterized in a cryogenic setup. Ions could be trapped and their life time and motional heating were investigated. Long ion lifetimes of several hours were observed and the measured heating rates were reproducibly low at around 1 phonon per second at a trap frequency of 1 MHz. (author) [de

  10. Molecular ion photofragment spectroscopy

    International Nuclear Information System (INIS)

    Bustamente, S.W.

    1983-11-01

    A new molecular ion photofragment spectrometer is described which features a supersonic molecular beam ion source and a radio frequency octapole ion trap interaction region. This unique combination allows several techniques to be applied to the problem of detecting a photon absorption event of a molecular ion. In particular, it may be possible to obtain low resolution survey spectra of exotic molecular ions by using a direct vibrational predissociation process, or by using other more indirect detection methods. The use of the spectrometer is demonstrated by measuring the lifetime of the O 2 + ( 4 π/sub u/) metastable state which is found to consist of two main components: the 4 π/sub 5/2/ and 4 π/sub -1/2/ spin components having a long lifetime (approx. 129 ms) and the 4 π/sub 3/2/ and 4 π/sub 1/2/ spin components having a short lifetime (approx. 6 ms)

  11. Ion mobility sensor system

    Science.gov (United States)

    Xu, Jun; Watson, David B.; Whitten, William B.

    2013-01-22

    An ion mobility sensor system including an ion mobility spectrometer and a differential mobility spectrometer coupled to the ion mobility spectrometer. The ion mobility spectrometer has a first chamber having first end and a second end extending along a first direction, and a first electrode system that generates a constant electric field parallel to the first direction. The differential mobility spectrometer includes a second chamber having a third end and a fourth end configured such that a fluid may flow in a second direction from the third end to the fourth end, and a second electrode system that generates an asymmetric electric field within an interior of the second chamber. Additionally, the ion mobility spectrometer and the differential mobility spectrometer form an interface region. Also, the first end and the third end are positioned facing one another so that the constant electric field enters the third end and overlaps the fluid flowing in the second direction.

  12. Adsorción de iones Ni(II) sobre una arcilla bentonítica peletizada

    OpenAIRE

    Carlos Mejía Miranda; Dionisio Laverde; Verónica Avella; Darío Yesid Peña Ballesteros

    2015-01-01

    La presencia de iones metálicos en aguas residuales genera un efecto tóxico para ecosistemas marinos y la salud pública. Las arcillas son materiales naturales con alta capacidad de adsorción y de bajo costo, viables para su implementación a nivel a industrial para la remoción de iones metálicos. Su implementación está limitada al desarrollo de alternativas para la utilización de estas arcillas a gran escala y en procesos continuos. La peletización de las arcillas permite su utilización en col...

  13. Oro para Colombia

    OpenAIRE

    Rubio Forero, María Claudia

    2016-01-01

    Las mujeres han debido atravesar un largo camino partiendo de la discriminación hasta empezar un proceso de equidad en la sociedad y en el deporte, de esta manera llegar a ser parte de un evento como los Juegos Olímpicos. Esta tesis toma el caso de tres atletas colombianas y describe su proceso de formación para lograr dos medallas de oro para el país.

  14. Plasma source ion implantation

    International Nuclear Information System (INIS)

    Conrad, J.R.; Forest, C.

    1986-01-01

    The authors' technique allows the ion implantation to be performed directly within the ion source at higher currents without ion beam extraction and transport. The potential benefits include greatly increased production rates (factors of 10-1000) and the ability to implant non-planar targets without rastering or shadowing. The technique eliminates the ion extractor grid set, beam raster equipment, drift space and target manipulator equipment. The target to be implanted is placed directly within the plasma source and is biased to a large negative potential so that plasma ions gain energy as they accelerate through the potential drop across the sheath that forms at the plasma boundary. Because the sheath surrounds the target on all sides, all surfaces of the target are implanted without the necessity to raster the beam or to rotate the target. The authors have succeeded in implanting nitrogen ions in a silicon target to the depths and concentrations required for surface treatment of materials like stainless steel and titanium alloys. They have performed ESCA measurements of the penetration depth profile of a silicon target that was biased to 30 kV in a nitrogen discharge plasma. Nitrogen ions were implanted to a depth of 700A at a peak concentration of 30% atomic. The measured profile is quite similar to a previously obtained profile in titanium targets with conventional techniques

  15. Desenvolvimento de um método empregando quitosana para remoção de íons metálicos de águas residuárias Development of a method employing chitosan to remove metallic ions from wastewater

    Directory of Open Access Journals (Sweden)

    Bruno Campos Janegitz

    2007-08-01

    Full Text Available In this work a method was developed for removing metallic ions from wastewaters by co-precipitation of Cu2+, Pb2+, Cd2+, Cr3+ and Hg2+ with chitosan and sodium hydroxide solution. Solutions of these metallic ions in the range from 0.55 to 2160 mg L-1 were added to chitosan dissolved in 0.05 mol L-1 HCl. For the co-precipitation of metal-chitosan-hydroxide a 0.17 mol L-1 NaOH solution was added until pH 8.5-9.5. A parallel study was carried out applying a 0.17 mol L-1 NaOH solution to precipitate those metallic ions. Also, a chitosan solid phase column was used for removing those metallic ions from wastewaters.

  16. Estrategias para negociaciones exitosas.

    Directory of Open Access Journals (Sweden)

    José B. Parra V

    2010-01-01

    Full Text Available Las estrategias de negociación son herramientas para disminuir conflictos o para intercambiar bienes y servicios. Una negociación exitosa crea relaciones de solidaridad y propicia reciprocidad, cooperación y confianza para quienes tendrán relaciones permanentes de negociación con beneficios para ambas partes. Una estrategia de negociación exitosa requiere manejar el desarrollo del ambiente social del grupo de personas, con la finalidad de tener presente las fronteras que no pueden irrumpirse. Otro aspecto importante, es el lenguaje corporal utilizado por las personas y las tácticas que se practican. El manejo de esta información permite diseñar diferentes modelos de negociaciones para cada caso específico. Este documento propone la utilización de la herramienta MONACO, diseñada por los autores, que es un software útil para encontrar los mejores tácticas posibles dentro de una negociación; basándose en el lenguaje corporal que muestra el negociante oponente durante cada oferta monetaria. El uso de este software da al negociador la oportunidad de manejar las negociaciones con mayor control, el negociador que usa el software puede elegir una estrategia de acuerdo a las relaciones que espera mantener con el negociador oponente.

  17. Jet laser ion source

    International Nuclear Information System (INIS)

    Dem'yanov, A.V.; Sidorov, S.V.

    1994-01-01

    External laser injector of multicharged ions (MCI) is developed in which wide-aperture aberration-free wire gauze spherical shape electrodes are applied for effective MCI extraction from laser plasma and beam focusing. Axial plasma compression by solenoid magnetic field is used to reduce ion losses due to transverse movement of the scattering laser plasma. Transverse magnetic field created by another solenoid facilitates the effective laser plasma braking and consequently, leads to the narrowing of energy spectrum of plasma ions and its shift towards lower energies. 2 refs.; 3 figs

  18. Heavy-ion dosimetry

    International Nuclear Information System (INIS)

    Schimmerling, W.

    1980-03-01

    This lecture deals with some of the more important physical characteristics of relativistic heavy ions and their measurement, with beam delivery and beam monitoring, and with conventional radiation dosimetry as used in the operation of the BEVALAC biomedical facility for high energy heavy ions (Lyman and Howard, 1977; BEVALAC, 1977). Even so, many fundamental aspects of the interaction of relativistic heavy ions with matter, including important atomic physics and radiation chemical considerations, are not discussed beyond the reminder that such additional understanding is required before an adequte perspective of the problem can be attained

  19. IN MEMORIAM ION VATAMANU

    Directory of Open Access Journals (Sweden)

    S.P. Palii

    2012-12-01

    Full Text Available A dreamer in his creative solitude, an objective and lucid analyst of history and contemporaneity, an energetic and decisive leader with an uncanny ability for crisis management – all these describe Ion Vatamanu. His wife Elena and daughters Mihaela, Mariana, Leontina treasure a personal universe in which the magical spark of Ion Vatamanu’s love and joy of life meld the everyday in and out of poetry. Ion Vatamanu’s instantaneous connection to the audiences and deeply felt words still touch the hearts of his many colleagues and friends. Downloads: 2

  20. Multivalent ion conducting solids

    Energy Technology Data Exchange (ETDEWEB)

    Imanaka, N. [Osaka Univ., Suita, Osaka (Japan). Dept. of Applied Chemistry

    2008-07-01

    Solid electrolytes possess important characteristics for industrial applications. Only a single ionic species can macroscopically migrate in these solids. This paper described a the new NASICON (M-Zr-Nb-P-O) type system, exhibiting an exceptionally high level of trivalent M3+ ion conductivity on polycrystalline solids. The partial substitution of the smaller higher valent Nb5+ ion for Zr4+ stabilized the NASICON phase and realized the M3+ ion conduction in the NASICON structure. It was concluded that the conductivities of the series are comparable to those of the practically applied solid electrolytes of oxide anion conductors of YSZ and CSZ. 3 refs., 2 figs.

  1. Ion implantation technology

    CERN Document Server

    Downey, DF; Jones, KS; Ryding, G

    1993-01-01

    Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach

  2. Metodologia para determinação de digluconato de clorhexidina em carcaças de frango utilizando CLAE - par iônico e avaliação de resíduos durante a refrigeração e congelamento HPLC - ion pairing determination of chlorhexidine digluconate in treated poultry carcasses. Analysis during refrigeration and freezing

    Directory of Open Access Journals (Sweden)

    Eduardo Vicente

    2003-12-01

    Full Text Available O uso do digluconato de clorhexidina (DGCH na higienização de equipamentos e instalações na indústria de alimentos e o interesse de aplicação deste produto como sanitizante em carcaças de frango indicam a necessidade da avaliação de resíduos no alimento. Um método por cromatografia líquida de alta eficiência (CLAE com pareamento de íons, incluindo extração com éter etílico em meio alcalino, foi desenvolvido para determinação de clorhexidina em carne de frango. O limite de quantificação do método (0,6mg/g e a recuperação média em carcaça (75% - CV 10%, em pele (72% - CV 7% e na musculatura (82% - CV 8% foram considerados adequados aos propósitos do método. As análises de carcaças e pele tratadas, mantidas refrigeradas ou congeladas, permitiu constatar que ocorreu uma pequena redução nos níveis residuais de DGCH durante o período de armazenamento. Como prováveis causas desta diminuição devem ser considerados a interação com componentes polares da matriz, a perda juntamente com os fluidos liberados dos tecidos durante o armazenamento refrigerado ou no descongelamento de carcaças inteiras e a degradação da clorhexidina. A ausência deste sanitizante na musculatura após o armazenamento refrigerado indica que nas condições empregadas, o DGCH não atravessa a barreira da pele.The use of the antimicrobial agent chlorhexidine digluconate in the sanitization of food industry equipment and installations, and the interest on its application to decontaminate poultry carcasses indicates the need to determine its residue in food. An ion pairing HPLC - UV analytical method including an ethyl ether extraction in alkaline medium was developed to measure clorhexidine residue in poultry meat. The limit of analytical quantitation (0,6mg/g and recoveries in carcasses (75% - CV 10%, skin (72% - CV 7%, and muscular tissue (82% - CV 8% were appropriate to the purposes of the method application. The analysis of treated

  3. EPR of uranium ions

    International Nuclear Information System (INIS)

    Ursu, I.; Lupei, V.

    1984-02-01

    A review of the electron paramagnetic resonance data on the uranium ions is given. After a general account of the electronic structure of the uranium free atoms and ions, the influence of the external fields (magnetic field, crystal fields) is discussed. The main information obtained from EPR studies on the uranium ions in crystals are emphasized: identification of the valence and of the ground electronic state, determination of the structure of the centers, crystal field effects, role of the intermediate coupling and of the J-mixing, role of the covalency, determination of the nuclear spin, maqnetic dipole moment and electric quadrupole moment of the odd isotopes of uranium. These data emphasize the fact that the actinide group has its own identity and this is accutely manifested at the beginning of the 5fsup(n) series encompassed by the uranium ions. (authors)

  4. Sensing with Ion Channels

    CERN Document Server

    Martinac, Boris

    2008-01-01

    All living cells are able to detect and translate environmental stimuli into biologically meaningful signals. Sensations of touch, hearing, sight, taste, smell or pain are essential to the survival of all living organisms. The importance of sensory input for the existence of life thus justifies the effort made to understand its molecular origins. Sensing with Ion Channels focuses on ion channels as key molecules enabling biological systems to sense and process the physical and chemical stimuli that act upon cells in their living environment. Its aim is to serve as a reference to ion channel specialists and as a source of new information to non specialists who want to learn about the structural and functional diversity of ion channels and their role in sensory physiology.

  5. Ion exchange phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Bourg, I.C.; Sposito, G.

    2011-05-01

    Ion exchange phenomena involve the population of readily exchangeable ions, the subset of adsorbed solutes that balance the intrinsic surface charge and can be readily replaced by major background electrolyte ions (Sposito, 2008). These phenomena have occupied a central place in soil chemistry research since Way (1850) first showed that potassium uptake by soils resulted in the release of an equal quantity of moles of charge of calcium and magnesium. Ion exchange phenomena are now routinely modeled in studies of soil formation (White et al., 2005), soil reclamation (Kopittke et al., 2006), soil fertilitization (Agbenin and Yakubu, 2006), colloidal dispersion/flocculation (Charlet and Tournassat, 2005), the mechanics of argillaceous media (Gajo and Loret, 2007), aquitard pore water chemistry (Tournassat et al., 2008), and groundwater (Timms and Hendry, 2007; McNab et al., 2009) and contaminant hydrology (Chatterjee et al., 2008; van Oploo et al., 2008; Serrano et al., 2009).

  6. Ion sensing method

    Science.gov (United States)

    Smith, Richard Harding; Martin, Glenn Brian

    2004-05-18

    The present invention allows the determination of trace levels of ionic substances in a sample solution (ions, metal ions, and other electrically charged molecules) by coupling a separation method, such as liquid chromatography, with ion selective electrodes (ISE) prepared so as to allow detection at activities below 10.sup.-6 M. The separation method distributes constituent molecules into fractions due to unique chemical and physical properties, such as charge, hydrophobicity, specific binding interactions, or movement in an electrical field. The separated fractions are detected by means of the ISE(s). These ISEs can be used singly or in an array. Accordingly, modifications in the ISEs are used to permit detection of low activities, specifically, below 10.sup.-6 M, by using low activities of the primary analyte (the molecular species which is specifically detected) in the inner filling solution of the ISE. Arrays constructed in various ways allow flow-through sensing for multiple ions.

  7. Ion beam diagnosis

    International Nuclear Information System (INIS)

    Strehl, P.

    1994-04-01

    This report is an introduction to ion beam diagnosis. After a short description of the most important ion beam parameters measurements of the beam current by means of Faraday cups, calorimetry, and beam current transformers and measurements of the beam profile by means of viewing screens, profile grids and scanning devices, and residual gas ionization monitors are described. Finally measurements in the transverse and longitudinal phase space are considered. (HSI)

  8. Radio frequency ion source

    CERN Document Server

    Shen Guan Ren; Gao Fu; LiuNaiYi

    2001-01-01

    The study on Radio Frequency Ion Source is mainly introduced, which is used for CIAE 600kV ns Pulse Neutron Generator; and obtained result is also presented. The RF ion source consists of a diameter phi 25 mm, length 200 mm, coefficient of expansion =3.5 mA, beam current on target >=1.5 mA, beam spot =100 h.

  9. Ion exchange equilibrium constants

    CERN Document Server

    Marcus, Y

    2013-01-01

    Ion Exchange Equilibrium Constants focuses on the test-compilation of equilibrium constants for ion exchange reactions. The book first underscores the scope of the compilation, equilibrium constants, symbols used, and arrangement of the table. The manuscript then presents the table of equilibrium constants, including polystyrene sulfonate cation exchanger, polyacrylate cation exchanger, polymethacrylate cation exchanger, polysterene phosphate cation exchanger, and zirconium phosphate cation exchanger. The text highlights zirconium oxide anion exchanger, zeolite type 13Y cation exchanger, and

  10. Miniaturized Ion Mobility Spectrometer

    Science.gov (United States)

    Kaye, William J (Inventor); Stimac, Robert M. (Inventor)

    2017-01-01

    By utilizing the combination of a unique electronic ion injection control circuit in conjunction with a particularly designed drift cell construction, the instantly disclosed ion mobility spectrometer (IMS) achieves increased levels of sensitivity, while achieving significant reductions in size and weight. The instant IMS is of a much simpler and easy to manufacture design, rugged and hermetically sealed, capable of operation at high temperatures to at least 250 degrees Centigrade, and is uniquely sensitive, particularly to explosive chemicals.

  11. Ion implantation - an introduction

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1986-01-01

    Ion implantation is a widely used technique with a literature that covers semiconductor production, surface treatments of steels, corrosion resistance, catalysis and integrated optics. This brief introduction outlines advantages of the technique, some aspects of the underlying physics and examples of current applications. Ion implantation is already an essential part of semiconductor technology while in many other areas it is still in an early stage of development. The future scope of the subject is discussed. (author)

  12. Improving Ion Computed Tomography

    DEFF Research Database (Denmark)

    Hansen, David Christoffer

    2014-01-01

    løsninger i stedet sat bruge ion CT, hvor patienten skannes med de samme partikler, der også bruges til selve strålebehandlingen. Med ion CT kan man beregne partiklernes rækkevidde med en præcision, der erbedre end 1.0%, men ion CT har også visse begrænsninger. Blandt andet gør den begrænsede rækkevidde af...... ionerne, at man ikke kan skanne områder tykkere end 30 − 37cm, alt afhængig af acceleratoren på behandlingsstedet. I denne ph.d afhandling undersøges flere af disse begrænsninger. Her præsenteres en ny algoritme, som kombinere ion CT med de røntgenbilleder, der laves i behandlingsrummet. Dermed kan man...... rekonstruere ion CT billeder, selvom partiklerne kun kan nå igennem patienten i halvdelen af de vinkler, man normalt ville skanne fra. Simulationer af ion CT er i høj grad afhængige af de fysiske modeller, der bruges til kerne-spaltning. Modellerne blev i denne afhandling undersøgt i Monte Carlo koden SHIELD...

  13. Collective focusing ion accelerator

    International Nuclear Information System (INIS)

    Goldin, F.J.

    1986-01-01

    The principal subject of this dissertation is the trapping confinement of pure electron plasmas in bumpy toroidal magnetic fields, with particular attention given to the trapping procedure and the behavior of the plasma during the final equilibrium. The most important aspects of the equilibrium studied were the qualitative nature of the plasma configuration and motion and its density, distribution and stability. The motivation for this study was that an unneutralized cloud of electrons contained in a toroidal system, sufficiently dense and stable, may serve to electrostatically focus ions (against centrifugal and self space charge forces) in a cyclic ion accelerator. Such an accelerator, known as a Collective Focusing Ion Accelerator (CFIA) could be far smaller than conventional designs (which use external magnetic fields directly to focus the ions) due to the smaller gyro-radium of an electron in a magnetic field of given strength. The electron cloud generally drifted poloidally at a finite radius from the toroidal minor axis. As this would preclude focusing ions with such clouds, damping this motion was investigated. Finite resistance in the normally perfectly conductive vessel wall did this. In further preparation for a working CFIA, additional experiments studied the effect of ions on the stability of the electron cloud

  14. 2010 ion run: completed!

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    After a very fast switchover from protons to lead ions, the LHC has achieved performances that allowed the machine to exceed both peak and integrated luminosity by a factor of three. Thanks to this, experiments have been able to produce high-profile results on ion physics almost immediately, confirming that the LHC was able to keep its promises for ions as well as for protons.   First direct observation of jet quenching. A seminar on 2 December was the opportunity for the ALICE, ATLAS and CMS collaborations to present their first results on ion physics in front of a packed auditorium. These results are important and are already having a major impact on the understanding of the physics processes that involve the basic constituents of matter at high energies. In the ion-ion collisions, the temperature is so high that partons (quarks and gluons), which are usually constrained inside the nucleons, are deconfined to form a highly dense and hot soup known as quark-gluon plasma (QGP). The existence of ...

  15. Present status of NIRS ECR ion sources

    NARCIS (Netherlands)

    Muramatsu, M.; Kitagawa, A.; Iwata, Y.; Yamamoto, K.; Ogawa, H.; Hojo, S.; Sakamoto, Y.; Honma, T.; Takasugi, W.; Wakaisami, M.; Yoshida, Y.; Kubo, T.; Kato, Y.; Biri, S.; Drentje, A. G.

    Four ECR ion sources have been operated in National Institute of Radiological Sciences (NIRS). Two ECR ion sources supply various ion species for the Heavy Ion Medical Accelerator in Chiba (HIMAC). The 10GHz NIRS-ECR ion source mainly produces C2+ ions for the heavy-ion therapy. Ions of Si, Ar, Fe,

  16. Ion mixing and numerical simulation of different ions produced in the ECR ion source

    International Nuclear Information System (INIS)

    Shirkov, G.D.

    1996-01-01

    This paper is to continue theoretical investigations and numerical simulations in the physics of ECR ion sources within the CERN program on heavy ion acceleration. The gas (ion) mixing effect in ECR sources is considered here. It is shown that the addition of light ions to the ECR plasma has three different mechanisms to improve highly charged ion production: the increase of confinement time and charge state of highly ions as the result of ion cooling; the concentration of highly charged ions in the central region of the source with high energy and density of electrons; the increase of electron production rate and density of plasma. The numerical simulations of lead ion production in the mixture with different light ions and different heavy and intermediate ions in the mixture with oxygen, are carried out to predict the principal ECR source possibilities for LHC applications. 18 refs., 23 refs

  17. Ion implantation for materials processing

    International Nuclear Information System (INIS)

    Smidt, F.A.

    1983-01-01

    This book reviews current research on ion implantation for materials processing as a viable technique for improving surface properties of metals and alloys-wear, fatigue, and corrosion. An introductory section on new potential applications of ion beam technology is provided. Contents: New potential applications of ion beam technology; ion implantation science and technology; wear and fatigue; corrosion; other research areas

  18. Tiempo para un cambio

    Science.gov (United States)

    Woltjer, L.

    1987-06-01

    En la reunion celebrada en diciembre dei ano pasado informe al Consejo de mi deseo de terminar mi contrato como Director General de la ESO una vez que fuera aprobado el proyecto dei VLT, que se espera sucedera hacia fines de este aAo. Cuando fue renovada mi designacion hace tres aAos, el Consejo conocia mi intencion de no completar los cinco aAos dei contrato debido a mi deseo de disponer de mas tiempo para otras actividades. Ahora, una vez terminada la fase preparatoria para el VLT, Y habiendose presentado el proyecto formalmente al Consejo el dia 31 de marzo, y esperando su muy probable aprobacion antes dei termino de este ano, me parece que el 10 de enero de 1988 presenta una excelente fecha para que se produzca un cambio en la administracion de la ESO.

  19. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1983-01-01

    Ion-Selective Electrode Reviews, Volume 5 is a collection of articles that covers ion-speciation. The book aims to present the advancements of the range and capabilities of selective ion-sensors. The topics covered in the selection are neutral carrier based ion-selective electrodes; reference electrodes and liquid junction effects in ion-selective electrode potentiometry; ion transfer across water/organic phase boundaries and analytical; and carbon substrate ion-selective electrodes. The text will be of great use to chemists and chemical engineers.

  20. Ion optics of RHIC EBIS

    Energy Technology Data Exchange (ETDEWEB)

    Pikin, A.; Alessi, J.; Beebe, E.; Kponou, A.; Okamura, M.; Raparia, D.; Ritter, J.; Tan, Y.; Kuznetsov, G.

    2011-09-10

    RHIC EBIS has been commissioned to operate as a versatile ion source on RHIC injection facility supplying ion species from He to Au for Booster. Except for light gaseous elements RHIC EBIS employs ion injection from several external primary ion sources. With electrostatic optics fast switching from one ion species to another can be done on a pulse to pulse mode. The design of an ion optical structure and the results of simulations for different ion species are presented. In the choice of optical elements special attention was paid to spherical aberrations for high-current space charge dominated ion beams. The combination of a gridded lens and a magnet lens in LEBT provides flexibility of optical control for a wide range of ion species to satisfy acceptance parameters of RFQ. The results of ion transmission measurements are presented.

  1. Instrucciones para autores

    OpenAIRE

    Martinez, Ana

    2012-01-01

    Instrucciones para autoresNota preliminar: ¡Es de suma importancia que antesde enviar cualquier documento a la Revista GeologíaColombiana, lea y cumpla cuidadosamente cada uno delos subíndices de las Normas para autores!A partir del Volumen 35 (2010) recibimos artículosprincipalmente a través del sistema digital enhttp://www.revistas.unal.edu.co/index.php/geocol/index.Si quiere enviar un artículo, por favor regístrese comoAutor en el menú INGRESAR (aquí pueden registrarsetambién evaluadores u...

  2. Master Plan para UNIMAK

    OpenAIRE

    Llorente Moreno, Francisco; Navarrete Mancebo, Gonzalo; Cruz Pinilla, Javier de la; García Méndez, María; Lacastagneratte de Figueiredo, Laura

    2012-01-01

    El Master Plan de UNIMAK se presenta como una apuesta a futuro, no solo para la Universidad de Makeni, sino también para la propia ciudad de Makeni. Se pretende potencias la Universidad como una referencia a nivel regional y como desencadenante de la estructura de trazado de la ciudad. El proyecto plantea potencial la dualidad que existe entre la infraestructura viaria y la red verde , existente en la ciudad, introduciéndola en el nuevo desarrollo del campus universitario y dotándola de la i...

  3. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1985-01-01

    Ion-Selective Electrode Reviews, Volume 7 is a collection of papers that covers the applications of electrochemical sensors, along with the versatility of ion-selective electrodes. The coverage of the text includes solid contact in membrane ion-selective electrodes; immobilized enzyme probes for determining inhibitors; potentiometric titrations based on ion-pair formation; and application of ion-selective electrodes in soil science, kinetics, and kinetic analysis. The text will be of great use to chemists and chemical engineers.

  4. Ion temperature gradient driven turbulence with strong trapped ion resonance

    Energy Technology Data Exchange (ETDEWEB)

    Kosuga, Y., E-mail: kosuga@riam.kyushu-u.ac.jp [Institute for Advanced Study, Kyushu University, Fukuoka (Japan); Research Institute for Applied Mechanics, Kyushu University, Fukuoka (Japan); Itoh, S.-I. [Research Center for Plasma Turbulence, Kyushu University, Fukuoka (Japan); Research Institute for Applied Mechanics, Kyushu University, Fukuoka (Japan); Diamond, P. H. [CASS and CMTFO, University of California at San Diego, La Jolla, California 92093 (United States); WCI Center for Fusion Theory, National Fusion Research Institute, Daejeon (Korea, Republic of); Itoh, K. [National Institute for Fusion Science, Gifu (Japan); Research Center for Plasma Turbulence, Kyushu University, Fukuoka (Japan); Lesur, M. [Research Institute for Applied Mechanics, Kyushu University, Fukuoka (Japan)

    2014-10-15

    A theory to describe basic characterization of ion temperature gradient driven turbulence with strong trapped ion resonance is presented. The role of trapped ion granulations, clusters of trapped ions correlated by precession resonance, is the focus. Microscopically, the presence of trapped ion granulations leads to a sharp (logarithmic) divergence of two point phase space density correlation at small scales. Macroscopically, trapped ion granulations excite potential fluctuations that do not satisfy dispersion relation and so broaden frequency spectrum. The line width from emission due only to trapped ion granulations is calculated. The result shows that the line width depends on ion free energy and electron dissipation, which implies that non-adiabatic electrons are essential to recover non-trivial dynamics of trapped ion granulations. Relevant testable predictions are summarized.

  5. Inverted magnetron ion source

    International Nuclear Information System (INIS)

    Singh, B.; Boyarsky, D.

    1985-01-01

    The present invention provides, in a preferred embodiment, a cylindrical stainless steel cathode with end pieces thereon to form a cathode chamber within. In addition, in a preferred embodiment, there is a stainless steel rod which passes axially through the cathode chamber and which is electrically insulated therefrom at the end pieces. The stainless steel cathode has first and second apertures formed therein with the first to be connected to a source of ionizable gas and the second to act as the opening through which there passes a stream of ions to an ion beam target. A magnetic flux source is coupled to the cathode chamber to pass magnetic flux therethrough and a voltage source is connected between the anode and the cathode to provide an electrostatic field therebetween whereby when ionizable gas is fed into the cathode chamber, it is ionized and a stream of ions emanates from the second aperture. In a preferred embodiment there is further provided an electrostatic ion focusing means to focus the ion stream emanating from the second aperture

  6. Ion transport in pigmentation.

    Science.gov (United States)

    Bellono, Nicholas W; Oancea, Elena V

    2014-12-01

    Skin melanocytes and ocular pigment cells contain specialized organelles called melanosomes, which are responsible for the synthesis of melanin, the major pigment in mammals. Defects in the complex mechanisms involved in melanin synthesis and regulation result in vision and pigmentation deficits, impaired development of the visual system, and increased susceptibility to skin and eye cancers. Ion transport across cellular membranes is critical for many biological processes, including pigmentation, but the molecular mechanisms by which it regulates melanin synthesis, storage, and transfer are not understood. In this review we first discuss ion channels and transporters that function at the plasma membrane of melanocytes; in the second part we consider ion transport across the membrane of intracellular organelles, with emphasis on melanosomes. We discuss recently characterized lysosomal and endosomal ion channels and transporters associated with pigmentation phenotypes. We then review the evidence for melanosomal channels and transporters critical for pigmentation, discussing potential molecular mechanisms mediating their function. The studies investigating ion transport in pigmentation physiology open new avenues for future research and could reveal novel molecular mechanisms underlying melanogenesis.

  7. Ion nitriding of aluminium

    International Nuclear Information System (INIS)

    Fitz, T.

    2002-09-01

    The present study is devoted to the investigation of the mechanism of aluminium nitriding by a technique that employs implantation of low-energy nitrogen ions and diffusional transport of atoms. The nitriding of aluminium is investigated, because this is a method for surface modification of aluminium and has a potential for application in a broad spectrum of fields such as automobile, marine, aviation, space technologies, etc. However, at present nitriding of aluminium does not find any large scale industrial application, due to problems in the formation of stoichiometric aluminium nitride layers with a sufficient thickness and good quality. For the purposes of this study, ion nitriding is chosen, as an ion beam method with the advantage of good and independent control over the process parameters, which thus can be related uniquely to the physical properties of the resulting layers. Moreover, ion nitriding has a close similarity to plasma nitriding and plasma immersion ion implantation, which are methods with a potential for industrial application. (orig.)

  8. Collisionless ion acoustic shocks in a negative-ion plasma

    International Nuclear Information System (INIS)

    Sheridan, T.E.

    1999-01-01

    Plasmas containing positive ions and electrons together with an additional negative component (e.g. negative ions or particulates) are of interest in subfields of plasma physics ranging from basic plasma physics (solitons and shocks, dusty plasmas) to ionospheric and space plasmas to plasma processing (electronegative discharges and particulate contamination). Such plasmas support two modes of the ion acoustic wave, a 'slow' mode where positive ions, negative ions and electrons oscillate in phase, and a 'fast' mode where negative ions oscillate out of phase with the other two components. When nonlinear steepening is considered, the fast wave may form a negative-potential solitary wave (NPSW), which, with the addition of dissipation (e.g. ion reflection, collisions, turbulence, electron Landau damping), will either disperse, or, more interestingly, form a shock. Recently, two experiments on the formation of shocks in a Q-machine plasma with negative ions have been reported. A low-temperature, negative-ion component was created when electrons attached to added SF 6 molecules. In such a plasma, the electron and positive ion temperatures are comparable (∼ 0.2 eV), so that when the negative ion concentration is small (< 50%), ion waves are strongly Landau damped since their phase velocity is comparable to the positive ion thermal velocity. However, a large negative ion concentration increases the phase velocity to a point where damping is weak. Conditions are then right for the formation of a shock. We have simulated shock formation in such a plasma

  9. alternativas para promoverla

    Directory of Open Access Journals (Sweden)

    Carlos Muñoz Izquierdo

    2006-01-01

    Finalmente, se analizan las políticas que han sido aplicadas con el fin de combatir ese problema, y se sugieren algunos cursos de acción que se consideran potencialmente más eficaces para lograr ese propósito.

  10. Silo para cereales. Bandholm

    Directory of Open Access Journals (Sweden)

    Editorial, Equipo

    1960-09-01

    Full Text Available El silo de Bandholm, para cereales, construido en la isla de Lolland, tiene una capacidad de 13 a 14.000 toneladas. Esta estructura se ha subdividido en células individuales de unas 400 toneladas de capacidad cada una. La obra ha sido proyectada y construida por Christiani & Nielsen.

  11. Dynamics of the ion-ion acoustic instability in the thermalization of ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Han, J.H.; Horton, W. (Texas Univ., Austin, TX (United States). Inst. for Fusion Studies); Leboeuf, J.N. (Oak Ridge National Lab., TN (United States))

    1992-07-01

    Particle simulation using a nonlinear adiabatic electron response with two streaming ion species and nonlinear theory are used to study the collisionless thermalization of ion beams in a hot electron plasma. The slow beam or subsonic regime is investigated and the criterion for the transition from predominantly light ion to predominantly heavy ion heating is developed. Long-lived ion hole structures a-re observed in the final state.

  12. Acceleration of radioactive ions

    International Nuclear Information System (INIS)

    Laxdal, R.E.

    2003-01-01

    There is an intense interest world-wide in the use of radioactive ion beams (RIBs) for experiment. In many existing or proposed facilities ions are produced or collected at source potential, ionized and re-accelerated. Within the past year three new ISOL based facilities have added dedicated post-accelerators to deliver accelerated RIBs to experiment. The paper gives an overview of RIB accelerators present and future, and explores the inherent features in the various acceleration methods with an emphasis on heavy ion linacs. The ISAC-I and ISAC-II post-accelerators are discussed as examples. Commissioning results and initial operating experience with ISAC-I will be presented

  13. Heavy ion inertial fusion

    International Nuclear Information System (INIS)

    Keefe, D.; Sessler, A.M.

    1980-01-01

    Inertial fusion has not yet been as well explored as magnetic fusion but can offer certain advantages as an alternative source of electric energy for the future. Present experiments use high-power beams from lasers and light-ion diodes to compress the deuterium-tritium (D-T) pellets but these will probably be unsuitable for a power plant. A more promising method is to use intense heavy-ion beams from accelerator systems similar to those used for nuclear and high-energy physics; the present paper addresses itself to this alternative. As will be demonstrated the very high beam power needed poses new design questions, from the ion-source through the accelerating system, the beam transport system, to the final focus. These problems will require extensive study, both theoretically and experimentally, over the next several years before an optimum design for an inertial fusion driver can be arrived at. (Auth.)

  14. Multicomponent ion exchange model

    International Nuclear Information System (INIS)

    Robinson, S.M.; Arnold, W.D.; Byers, C.H.

    1990-01-01

    The optimization of ion-exchange column design becomes increasingly important in applications where high efficiency is required to remove trace components in wastewater to very low discharge requirements and for treating hazardous wastewaters where the disposal costs for secondary waste is extremely high. A predictive mathematical model is being developed for improved design of ion-exchange columns for treatment of wastewaters which are contaminated with trace quantities of Sr-90 and Cs-137. Equilibria isotherms and mass transfer mechanisms are being experimentally determined for isothermal multicomponent ion exchange of Ca, Mg, Na, Ca, and Sr with Ionsive IE-95 chabazite zeolite. These equations are being included in a mathematical model to determine the cation breakthrough curves for different column configurations and operating conditions

  15. Heavy-ion radiography

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Tobias, C.A.; Holley, W.R.; Benton, E.V.

    1981-01-01

    Heavy-particle radiography has clinical potential as a newly developed noninvasive low-dose imaging procedure that provides increased resolution of minute density differences in soft tissues of the body. The method utilizes accelerated high-energy ions, primarily carbon and neon, at the Bevalac accelerator at the Lawrence Berkeley Laboratory. The research program for medicine utilizes heavy-ion radiography for low-dose mammography, for treatment planning for cancer patients, and for imaging and accurate densitometry of skeletal structures, brain and spinal neoplasms, and the heart. The potential of heavy-ion imaging, and particularly reconstruction tomography, is now proving to be an adjunct to existing diagnostic imaging procedures in medicine, both for applications to the diagnosis, management and treatment of clinical cancer in man, and for the early detection of small soft-tissue tumors at low radiation dose

  16. Microwave ion source

    Science.gov (United States)

    Leung, Ka-Ngo; Reijonen, Jani; Thomae, Rainer W.

    2005-07-26

    A compact microwave ion source has a permanent magnet dipole field, a microwave launcher, and an extractor parallel to the source axis. The dipole field is in the form of a ring. The microwaves are launched from the middle of the dipole ring using a coaxial waveguide. Electrons are heated using ECR in the magnetic field. The ions are extracted from the side of the source from the middle of the dipole perpendicular to the source axis. The plasma density can be increased by boosting the microwave ion source by the addition of an RF antenna. Higher charge states can be achieved by increasing the microwave frequency. A xenon source with a magnetic pinch can be used to produce intense EUV radiation.

  17. Magnetic ions in crystals

    CERN Document Server

    Stevens, K W

    2014-01-01

    There have been many demonstrations, particularly for magnetic impurity ions in crystals, that spin-Hamiltonians are able to account for a wide range of experimental results in terms of much smaller numbers of parameters. Yet they were originally derived from crystal field theory, which contains a logical flaw; electrons on the magnetic ions are distinguished from those on the ligands. Thus there is a challenge: to replace crystal field theory with one of equal or greater predictive power that is based on a surer footing. The theory developed in this book begins with a generic Hamiltonian, on

  18. Ion-selective electrodes

    CERN Document Server

    Mikhelson, Konstantin N

    2013-01-01

    Ion-selective electrodes (ISEs) have a wide range of applications in clinical, environmental, food and pharmaceutical analysis as well as further uses in chemistry and life sciences. Based on his profound experience as a researcher in ISEs and a course instructor, the author summarizes current knowledge for advanced teaching and training purposes with a particular focus on ionophore-based ISEs. Coverage includes the basics of measuring with ISEs, essential membrane potential theory and a comprehensive overview of the various classes of ion-selective electrodes. The principles of constructing I

  19. Small Column Ion Exchange

    International Nuclear Information System (INIS)

    Huff, Thomas

    2010-01-01

    Small Column Ion Exchange (SCIX) leverages a suite of technologies developed by DOE across the complex to achieve lifecycle savings. Technologies are applicable to multiple sites. Early testing supported multiple sites. Balance of SRS SCIX testing supports SRS deployment. A forma Systems Engineering Evaluation (SEE) was performed and selected Small Column Ion Exchange columns containing Crystalline Silicotitanate (CST) in a 2-column lead/lag configuration. SEE considered use of Spherical Resorcinol-Formaldehyde (sRF). Advantages of approach at SRS include: (1) no new buildings, (2) low volume of Cs waste in solid form compared to aqueous strip effluent; and availability of downstream processing facilities for immediate processing of spent resin.

  20. Intense negative heavy ion sources

    Science.gov (United States)

    Mori, Yoshiharu; Takagi, Akira; Ikegami, Kiyoshi; Ueno, Akira; Fukumoto, Sadayoshi

    1990-08-01

    Negative ion sources based on plasma-surface interactions (BLAKE ion source) have been developed at KEK for producing negative heavy ions. The first negative heavy ion source (BLAKE-II) was developed by modifying the ordinary negative hydrogen ion source with converter (BLAKE-I) placed into the plasma. It generates various species of negative heavy ions with intense beam currents. For example, a more than 10 mA Au- ion beam was obtained from the ion source. Recently, the large scaled negative heavy ion source (BLAKE-III) has been developed and in the preliminary test experiment, more than 100 mA Cu- ion beam has been stably obtained with a 10% duty factor in pulsed operation. The BLAKE-II ion source was attached to the BNL 15 MV and Tsukuba University TANDEM accelerators and large current negative heavy ion beams were successfully accelerated in pulsed mode operation. Also, it was found that the space charge effect should be carefully considered for such a large current acceleration in a tandem accelerator, especially at the injection beam line and low energy end. In order to examine the negative ion formation process fundamentally, negative ion production probability related on sputtered particle velocity was measured and the results showed exponential dependence of the production probability on particle velocity as Norskov and Lindquist's theory predicted.

  1. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1982-01-01

    Ion-Selective Electrode Reviews, Volume 3, provides a review of articles on ion-selective electrodes (ISEs). The volume begins with an article on methods based on titration procedures for surfactant analysis, which have been developed for discrete batch operation and for continuous AutoAnalyser use. Separate chapters deal with detection limits of ion-selective electrodes; the possibility of using inorganic ion-exchange materials as ion-sensors; and the effect of solvent on potentials of cells with ion-selective electrodes. Also included is a chapter on advances in calibration procedures, the d

  2. Analytical applications of ion exchangers

    CERN Document Server

    Inczédy, J

    1966-01-01

    Analytical Applications of Ion Exchangers presents the laboratory use of ion-exchange resins. This book discusses the development in the analytical application of ion exchangers. Organized into 10 chapters, this book begins with an overview of the history and significance of ion exchangers for technical purposes. This text then describes the properties of ion exchangers, which are large molecular water-insoluble polyelectrolytes having a cross-linked structure that contains ionic groups. Other chapters consider the theories concerning the operation of ion-exchange resins and investigate th

  3. Molecular ion sources for low energy semiconductor ion implantation (invited).

    Science.gov (United States)

    Hershcovitch, A; Gushenets, V I; Seleznev, D N; Bugaev, A S; Dugin, S; Oks, E M; Kulevoy, T V; Alexeyenko, O; Kozlov, A; Kropachev, G N; Kuibeda, R P; Minaev, S; Vizir, A; Yushkov, G Yu

    2016-02-01

    Smaller semiconductors require shallow, low energy ion implantation, resulting space charge effects, which reduced beam currents and production rates. To increase production rates, molecular ions are used. Boron and phosphorous (or arsenic) implantation is needed for P-type and N-type semiconductors, respectively. Carborane, which is the most stable molecular boron ion leaves unacceptable carbon residue on extraction grids. A self-cleaning carborane acid compound (C4H12B10O4) was synthesized and utilized in the ITEP Bernas ion source resulting in large carborane ion output, without carbon residue. Pure gaseous processes are desired to enable rapid switch among ion species. Molecular phosphorous was generated by introducing phosphine in dissociators via 4PH3 = P4 + 6H2; generated molecular phosphorous in a pure gaseous process was then injected into the HCEI Calutron-Bernas ion source, from which P4(+) ion beams were extracted. Results from devices and some additional concepts are described.

  4. Polyatomic ions from a high current ion implanter driven by a liquid metal ion source

    Science.gov (United States)

    Pilz, W.; Laufer, P.; Tajmar, M.; Böttger, R.; Bischoff, L.

    2017-12-01

    High current liquid metal ion sources are well known and found their first application as field emission electric propulsion thrusters in space technology. The aim of this work is the adaption of such kind of sources in broad ion beam technology. Surface patterning based on self-organized nano-structures on, e.g., semiconductor materials formed by heavy mono- or polyatomic ion irradiation from liquid metal (alloy) ion sources (LMAISs) is a very promising technique. LMAISs are nearly the only type of sources delivering polyatomic ions from about half of the periodic table elements. To overcome the lack of only very small treated areas by applying a focused ion beam equipped with such sources, the technology taken from space propulsion systems was transferred into a large single-end ion implanter. The main component is an ion beam injector based on high current LMAISs combined with suited ion optics allocating ion currents in the μA range in a nearly parallel beam of a few mm in diameter. Different types of LMAIS (needle, porous emitter, and capillary) are presented and characterized. The ion beam injector design is specified as well as the implementation of this module into a 200 kV high current ion implanter operating at the HZDR Ion Beam Center. Finally, the obtained results of large area surface modification of Ge using polyatomic Bi2+ ions at room temperature from a GaBi capillary LMAIS will be presented and discussed.

  5. Ion implantation into diamond

    International Nuclear Information System (INIS)

    Sato, Susumu

    1994-01-01

    The graphitization and the change to amorphous state of diamond surface layer by ion implantation and its characteristics are reported. In the diamond surface, into which more than 10 16 ions/cm 2 was implanted, the diamond crystals are broken, and the structure changes to other carbon structure such as amorphous state or graphite. Accompanying this change of structure, the electric conductivity of the implanted layer shows two discontinuous values due to high resistance and low resistance. This control of structure can be done by the temperature of the base during the ion implantation into diamond. Also it is referred to that by the base temperature during implantation, the mutual change of the structure between amorphous state and graphite can be controlled. The change of the electric resistance and the optical characteristics by the ion implantation into diamond surface, the structural analysis by Raman spectroscopy, and the control of the structure of the implanted layer by the base temperature during implantation are reported. (K.I.)

  6. Ion Mass Determination

    DEFF Research Database (Denmark)

    2010-01-01

    An apparatus (100) is described for determining the mass of ions, the apparatus configured to hold a plasma (101 ) having a plasma potential. The apparatus (100) comprises an electrode (102) having a surface extending in a surface plane and an insulator (104) interfacing with the electrode (102...

  7. Ion Implantation of Polymers

    DEFF Research Database (Denmark)

    Popok, Vladimir

    2012-01-01

    is put on the low-energy implantation of metal ions causing the nucleation and growth of nanoparticles in the shallow polymer layers. Electrical, optical and magnetic properties of metal/polymer composites are under the discussion and the approaches towards practical applications are overviewed....

  8. CLASSICS The Ions

    Indian Academy of Sciences (India)

    solution is called electrolytic dissociation, and this process is a chemical reaction coming under the general laws already discussed. A salt solution gives back the original salt unchanged when it is evaporated, and this proves clearly that the dissociation into ions is reversed when the salt separates. The question arises ...

  9. Heavy ion fusion

    International Nuclear Information System (INIS)

    Hofmann, Ingo

    1993-01-01

    With controlled thermonuclear fusion holding out the possibility of a prolific and clean new source of energy, the goal remains elusive after many years of continual effort. While the conventional Tokamak route with magnetic confinement continues to hit the headlines, other alternatives are now becoming competitive. One possible solution is to confine the thermonuclear fuel pellet by high power beams. Current research and perspectives for future work in such inertial confinement was the subject of the 'Prospects for Heavy Ion Fusion' European Research Conference held in Aghia Pelaghia, Crete, last year. Its main focus was on the potential of heavy ion accelerators as well as recent advances in target physics with high power lasers and light ion beams. Carlo Rubbia declared that high energy accelerators, with their high efficiency, are the most promising approach to economical fusion energy production. However the need for cost saving in the driver accelerator requires new ideas in target design tailored to the particularities of heavy ion beams, which need to be pushed to the limits of high current and phase space density at the same time

  10. Field ion microscopy

    International Nuclear Information System (INIS)

    Ramanathan, D.

    1975-01-01

    The basic features of the Field-Ion Microscope (FIM) and the theory of image formation are explained. Design parameters of the FIM, factors limiting its resolution, interpretation of the image, etc are briefly outlined. Relative merits of the various imaging gases and the applications of the FIM are also covered. (K.B.)

  11. Ion-Beam-Excited Electrostatic Ion Cyclotron Waves

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1976-01-01

    Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field.......Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field....

  12. Compact RF ion source for industrial electrostatic ion accelerator

    Science.gov (United States)

    Kwon, Hyeok-Jung; Park, Sae-Hoon; Kim, Dae-Il; Cho, Yong-Sub

    2016-02-01

    Korea Multi-purpose Accelerator Complex is developing a single-ended electrostatic ion accelerator to irradiate gaseous ions, such as hydrogen and nitrogen, on materials for industrial applications. ELV type high voltage power supply has been selected. Because of the limited space, electrical power, and robust operation, a 200 MHz RF ion source has been developed. In this paper, the accelerator system, test stand of the ion source, and its test results are described.

  13. Ion transport from plasma ion source at ISOLTRAP

    CERN Document Server

    Steinsberger, Timo Pascal

    2017-01-01

    In this report, my work as CERN Summer Student at the ISOLTRAP experiment at ISOLDE is described. A new plasma ion source used as oine source for calibration and implemented before my arrival was commissioned and transportation settings for the produced ions to the ion traps were found. The cyclotron frequencies of 40Ar and the xenon isotopes 129-132Xe were measured using time-of-flight and phase-imaging ion-cyclotron-resonance mass spectroscopy.

  14. Instrucciones para autores y autoras

    OpenAIRE

    Casa de la Mujer, Revista

    2015-01-01

    Le recomendamos leer este documento a profundidad para queconozca las políticas y normas para postular a consideración su escrito.Estas instrucciones se organizan en tres apartados: I. Datos básicos,II. Políticas y III. Lineamientos para presentar el escrito; para la citacióny referenciación con APA se ofrece el documento titulado Guía dereferenciación y citación con APA.

  15. ParaChoice Model.

    Energy Technology Data Exchange (ETDEWEB)

    Heimer, Brandon Walter [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Levinson, Rebecca Sobel [Sandia National Lab. (SNL-CA), Livermore, CA (United States); West, Todd H. [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2017-12-01

    Analysis with the ParaChoice model addresses three barriers from the VTO Multi-Year Program Plan: availability of alternative fuels and electric charging station infrastructure, availability of AFVs and electric drive vehicles, and consumer reluctance to purchase new technologies. In this fiscal year, we first examined the relationship between the availability of alternative fuels and station infrastructure. Specifically, we studied how electric vehicle charging infrastructure affects the ability of EVs to compete with vehicles that rely on mature, conventional petroleum-based fuels. Second, we studied how the availability of less costly AFVs promotes their representation in the LDV fleet. Third, we used ParaChoice trade space analyses to help inform which consumers are reluctant to purchase new technologies. Last, we began analysis of impacts of alternative energy technologies on Class 8 trucks to isolate those that may most efficaciously advance HDV efficiency and petroleum use reduction goals.

  16. Resina pet para recipientes

    OpenAIRE

    Montenegro, Ricardo Sá Peixoto; Monteiro Filha, Dulce Corrêa; Pan, Simon Shi Koo

    1996-01-01

    O mercado potencial de resina PET para recipientes é grande, com ampla expectativa de expansão. A nível mundial, esta ocorrendo um ciclo de expansão que deverá levar a uma sobrecapacidade, pressionando os preços para baixo. No Brasil, a escassez de resina PET tem retardado sua maior utilização em recipientes, notadamente de bebidas carbonatadas e em mercados em desenvolvimento, como o de óleo comestível e água mineral. Com a entrada em operação da fábrica da Nitrocarbono e da expansão da Rhod...

  17. Educando para la ignorancia

    Directory of Open Access Journals (Sweden)

    Miguel Durán

    1996-06-01

    Full Text Available Más que describir una situación particular, los autores buscan con este escrito motivar al estudiante para que asuma posiciones críticas; así como dar un campanazo de alerta a los profesores, en relación a los conocimientos que transmiten a sus alumnos y la forma en que lo hacen; todo con el ánimo de generar verdaderos espacios de reflexión en la universidad.

  18. Unstable Electrostatic Ion Cyclotron Waves Exited by an Ion Beam

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1976-01-01

    Electrostatic ion cyclotron waves were observed in a quiescent cesium plasma into which a low‐energy beam of sodium ions was injected. The instability appeared when the beam velocity was above 12 times the ion thermal velocity. The waves propagated along the magnetic field with a velocity somewhat...

  19. Cs+ ion source for secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Bentz, B.L.; Weiss, H.; Liebl, H.

    1981-12-01

    Various types of cesium ionization sources currently used in secondary ion mass spectrometry are briefly reviewed, followed by a description of the design and performance of a novel, thermal surface ionization Cs + source developed in this laboratory. The source was evaluated for secondary ion mass spectrometry applications using the COALA ion microprobe mass analyzer. (orig.)

  20. ECR ion source based low energy ion beam facility

    Indian Academy of Sciences (India)

    Mass analyzed highly charged ion beams of energy ranging from a few keV to a few MeV plays an important role in various aspects of research in modern physics. In this paper a unique low energy ion beam facility (LEIBF) set up at Nuclear Science Centre (NSC) for providing low and medium energy multiply charged ion ...

  1. Using Ion Exchange Chromatography to Separate and Quantify Complex Ions

    Science.gov (United States)

    Johnson, Brian J.

    2014-01-01

    Ion exchange chromatography is an important technique in the separation of charged species, particularly in biological, inorganic, and environmental samples. In this experiment, students are supplied with a mixture of two substitution-inert complex ions. They separate the complexes by ion exchange chromatography using a "flash"…

  2. Heavy-ion radiography and heavy-ion computed tomography

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Holley, W.R.; McFarland, E.W.; Tobias, C.a.

    1982-02-01

    Heavy-ion projection and CT radiography is being developed into a safe, low-dose, noninvasive radiological procedure that can quantitate and image small density differences in human tissues. The applications to heavy-ion mammography and heavy-ion CT imaging of the brain in clinical patients suggest their potential value in cancer diagnosis

  3. Heavy-ion radiography and heavy-ion computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fabrikant, J.I.; Holley, W.R.; McFarland, E.W.; Tobias, C.a.

    1982-02-01

    Heavy-ion projection and CT radiography is being developed into a safe, low-dose, noninvasive radiological procedure that can quantitate and image small density differences in human tissues. The applications to heavy-ion mammography and heavy-ion CT imaging of the brain in clinical patients suggest their potential value in cancer diagnosis.

  4. Radioactive ion microscopy

    International Nuclear Information System (INIS)

    Johnson, S.A.

    1980-01-01

    A novel approach has been studied for the characterization of specimens with a spatial resolution at the micron level. The technique dubbed Radioactive Ion Microscopy, (RIM) uses a beam of radioactive ions, specifically tritium ions, of sufficient energy to pass through a thick specimen (e.g. greater than or equal to 10 μm). After passage through the object, the ions are implanted in a stack of thin mylar sheets (1.5 microns thick). Their rest position is proportional to the thickness and the density of the sample transversed. The location of the radioactive species can be pinpointed by autoradiographing the successive mylar foils. The radiographs are photographed and converted into digital data which is used to generate a density map of the object. From these plots, physical and chemical features may be deduced. The feasibility of RIM has been demonstrated with specimen images obtained from different objects exposed to a 3 MeV 3 H + beam. The specimens used included metal grids to examine spatial resolution and a series of biological samples (cork, wood, mosquito wing) to explore the performance and applicability of RIM. On these samples, which were 10 to 30 microns thick with surface areas of up to 1 cm 2 , a lateral resolution of approx. 1.5 microns was achieved. A depth resolution or sensitivity to density gradients of 0.2 mg/cm 2 was obtained. These detailed specimen images can be obtained with low beam exposures, e.g., in the case of tritium approx. 6 x 10 10 ions/cm 2 must be implanted, which corresponds to an irradiation of approx. 10 pA/cm 2 for 1000 s. The corresponding low radiation doses and minimal heat dissipation render RIM well suited for biological specimens. In comparison to light microscopy, RIM features enhanced microscopic capabilities as it can handle objects that are at the same time opaque to light, thick (up to tens of microns), and fragile

  5. Hidden ion population: Revisited

    International Nuclear Information System (INIS)

    Olsen, R.C.; Chappell, C.R.; Gallagher, D.L.; Green, J.L.; Gurnett, D.A.

    1985-01-01

    Satellite potentials in the outer plasmasphere range from near zero to +5 to +10 V. Under such conditions ion measurements may not include the low energy core of the plasma population. In eclipse, the photoelectron current drops to zero, and the spacecraft potential can drop to near zero volts. In regions where the ambient plasma density is below 100 cm -3 , previously unobserved portions of the ambient plasma distribution function can become visible in eclipse. A survey of the data obtained from the retarding ion mass spectrometer (RIMS) on Dynamics Explorer 1 shows that the RIMS detector generally measured the isotropic background in both sunlight and eclipse in the plasma-sphere. Absolute density measurements for the ''hidden'' ion population are obtained for the first time using the plasma wave instrument observations of the upper hybrid resonance. Agreement in total density is found in sunlight and eclipse measurements at densities above 80 cm -3 . In eclipse, agreement is found at densities as low as 20 cm -3 . The isotropic plasma composition is primarily H + , with approx.10% He + , and 0.1 to 1.0% O + . A low energy field-aligned ion population appears in eclipse measurements outside the plasmasphere, which is obscured in sunlight. These field-aligned ions can be interpreted as field-aligned flows with densities of a few particles per cubic centimeter, flowing at 5-20 km/s. The problem in measuring these field-aligned flows in sunlight is the masking of the high energy tail of the field-aligned distribution by the isotropic background. Effective measurement of the core of the magnetospheric plasma distribution awaits satellites with active means of controlling the satellite potential

  6. Negative ion sources for tandem accelerator

    International Nuclear Information System (INIS)

    Minehara, Eisuke

    1980-08-01

    Four kinds of negative ion sources (direct extraction Duoplasmatron ion source, radial extraction Penniing ion source, lithium charge exchange ion source and Middleton-type sputter ion source) have been installed in the JAERI tandem accelerator. The ion sources can generate many negative ions ranging from Hydrogen to Uranium with the exception of Ne, Ar, Kr, Xe and Rn. Discussions presented in this report include mechanisms of negative ion formation, electron affinity and stability of negative ions, performance of the ion sources and materials used for negative ion production. Finally, the author will discuss difficult problems to be overcome in order to get any negative ion sufficiently. (author)

  7. INICIATIVAS PARA EL CAMBIO

    Directory of Open Access Journals (Sweden)

    César Alfonso Defrancisco-Larrañaga

    2013-07-01

    Full Text Available El planeta no atraviesa por su mejor momento en materia de conservación y renovación de sus recursos naturales. Claramente en los últimos tiempos los recursos hídricos han venido haciéndose cada vez menores; el hombre ha notado con preocupación y vivido en carne propia este fenómeno, que de no ser tratado a tiempo, podría atentar contra la existencia misma. Esto lo ha alentado a buscar métodos que sirvan como solución para contrarrestar éste mal y crear conciencia entre sus iguales, para así poder garantizar su permanencia y la de su entorno durante muchas generaciones. En países desarrollados del continente europeo y en algunos lugares de América del norte, el uso de sistemas de reutilización y tratamiento de aguas grises y aprovechamiento de las aguas lluvias se ha convertido en una constante y nos están dando las pautas para poder seguir el ejemplo y así de esta manera poder aportar a la causa ambiental y a su vez crear un ahorro en nuestros gastos mensuales de consumo.

  8. Bullying: Conhecer para Prevenir

    Directory of Open Access Journals (Sweden)

    Elisabete Fernandes

    2016-01-01

    Full Text Available O bullying é um fenómeno que suscita a apreensão de toda a sociedade. Deste modo, enquanto pais, educadores e profissionais, devemos reconhecer que a violência entre pares em meio escolar afeta gravemente o desenvolvimento saudável das crianças. Conhecer e identificar as causas que estão na origem do bullying, bem como as consequências que este comportamento acarreta no desenvolvimento psicossocial dos seus alvos, é fundamental para melhor intervir. Proteger as crianças e jovens de hoje contribui para potenciar um futuro sem violência, através da existência de adultos equilibrados. Assim, a criação e implementação de estratégias de prevenção do bullying em contexto escolar constitui-se como dever social, porquanto só através de diversificadas conjugações de esforços será possível contribuir para um amanhã mais seguro.

  9. Low-altitude ion heating with downflowing and upflowing ions

    Science.gov (United States)

    Shen, Y.; Knudsen, D. J.; Burchill, J. K.; Howarth, A. D.; Yau, A. W.; James, G.; Miles, D.; Cogger, L. L.; Perry, G. W.

    2017-12-01

    Mechanisms that energize ions at the initial stage of ion upflow are still not well understood. We statistically investigate ionospheric ion energization and field-aligned motion at very low altitudes (330-730 km) using simultaneous plasma, magnetic field, wave electric field and optical data from the e-POP satellite. The high-time-resolution (10 ms) dataset enables us to study the micro-structures of ion heating and field-aligned ion motion. The ion temperature and field-aligned bulk flow velocity are derived from 2-D ion distribution functions measured by the SEI instrument. From March 2015 to March 2016, we've found 17 orbits (in total 24 ion heating periods) with clear ion heating signatures passing across the dayside cleft or the nightside auroral regions. Most of these events have consistent ion heating and flow velocity characteristics observed from both the SEI and IRM instruments. The perpendicular ion temperature goes up to 4.5 eV within a 2 km-wide region in some cases, in which the Radio Receiver Instrument (RRI) sees broadband extremely low frequency (BBELF) waves, demonstrating significant wave-ion heating down to as low as 350 km. The e-POP Fast Auroral Imager (FAI) and Magnetic Field (MGF) instruments show that many events are associated with active aurora and are within downward current regions. Contrary to what would be expected from mirror-force acceleration of heated ions, the majority of these heating events (17 out of 24) are associated with the core ion downflow rather than upflow. These statistical results provide us with new sights into ion heating and field-aligned flow processes at very low altitudes.

  10. Swift Heavy Ions in Matter

    International Nuclear Information System (INIS)

    1989-01-01

    The 1989 Symposium on Swift Heavy Ions in Matter is reported. The aim of the symposium is to evidence another aspect of heavy ions research at the interplay between atomic and solid state physics. The scope of the Symposium includes the fundamental aspects of heavy ion excitation, ionization, charge exchange, energy loss, energy dissipation and relaxation in solids, channeling and coherent effects in crystals and ion induced modifications of materials

  11. Membranes in Lithium Ion Batteries

    Directory of Open Access Journals (Sweden)

    Junbo Hou

    2012-07-01

    Full Text Available Lithium ion batteries have proven themselves the main choice of power sources for portable electronics. Besides consumer electronics, lithium ion batteries are also growing in popularity for military, electric vehicle, and aerospace applications. The present review attempts to summarize the knowledge about some selected membranes in lithium ion batteries. Based on the type of electrolyte used, literature concerning ceramic-glass and polymer solid ion conductors, microporous filter type separators and polymer gel based membranes is reviewed.

  12. Nanopatterning by Swift Heavy Ions

    OpenAIRE

    Skupinski, Marek

    2006-01-01

    Today, the dominating way of patterning nanosystems is by irradiation-based lithography (e-beam, DUV, EUV, and ions). Compared to the other irradiations, ion tracks created by swift heavy ions in matter give the highest contrast, and its inelastic scattering facilitate minute widening and high aspect ratios (up to several thousands). Combining this with high resolution masks it may have potential as lithography technology for nanotechnology. Even if this ‘ion track lithography’ would not give...

  13. Numerical simulation of ion temperature gradient driven modes in the presence of ion-ion collisions

    International Nuclear Information System (INIS)

    Xu, X.Q.

    1990-08-01

    Ion temperature gradient driven modes in the presence of ion-ion collisions in a toroidal geometry with trapped ions have been studied by using a 1 2/2 d linearized gyro-kinetic particle simulation code in the electrostatic limit. The purpose of the investigation is to try to understand the physics of flat density discharges, in order to test the marginal stability hypothesis. Results giving threshold conditions of L Ti /R 0 , an upper bound on k χ , and linear growth rates and mode frequencies over all wavelengths for the collisionless ion temperature gradient driven modes are obtained. The behavior of ion temperature gradient driven instabilities in the transition from slab to toroidal geometry, with trapped ions, is shown. A Monte Carlo scheme for the inclusion of ion-ion collisions, in which ions can undergo Coulomb collisional dynamical friction, velocity space diffusion and random walk of guiding centers, has been constructed. The effects of ion-ion collisions on the long wave length limit of the ion modes is discussed. 44 refs., 12 figs

  14. Ion temperature via laser scattering on ion Bernstein waves

    International Nuclear Information System (INIS)

    Wurden, G.A.; Ono, M.; Wong, K.L.

    1981-10-01

    Hydrogen ion temperature has been measured in a warm toroidal plasma with externally launched ion Bernstein waves detected by heterodyne CO 2 laser scattering. Radial scanning of the laser beam allows precise determination of k/sub perpendicular to/ for the finite ion Larmor radius wave (ω approx. less than or equal to 2Ω/sub i/). Knowledge of the magnetic field strength and ion concentration then give a radially resolved ion temperature from the dispersion relation. Probe measurements and Doppler broadening of ArII 4806A give excellent agreement

  15. Ion Accelerator Merges Several Beams

    Science.gov (United States)

    Aston, G.

    1984-01-01

    Intense ion beam formed by merging multiple ion beamlets into one concentrated beam. Beamlet holes in graphite screen and focusing grids arranged in hexagonal pattern. Merged beam passes through single hole in each of aluminum accelerator and decelerator grids. Ion extraction efficiency, beam intensity, and focusing improved.

  16. Síntese de zeólita tipo NaA a partir de caulim para obtenção de zeólita 5A através de troca iônica Synthesis of NaA zeolites from kaolin for obtaining 5A zeolites through ion exchange

    Directory of Open Access Journals (Sweden)

    C. R. Melo

    2010-12-01

    Full Text Available A síntese de zeólitas com o intuito de utilizá-las posteriormente como materiais adsorventes exige rigoroso controle das variáveis de processamento. Para cada tipo diferente de zeólita, existem variáveis de processo distintas para obtenção do tipo específico desejado. Neste trabalho os objetivos foram obter zeólita NaA partindo de caulim, para posteriormente obter zeólita 5A por meio de troca iônica com esta zeólita anteriormente sintetizada. Estas zeólitas, por sua vez, podem ser usadas como adsorventes altamente seletivos para adsorver, por exemplo, metais pesados de efluentes industriais. Os resultados obtidos foram satisfatórios, a metodologia utilizada mostrou-se eficiente. A partir do metacaulim comercial utilizado, obteve-se com sucesso zeólita tipo NaA, e por meio de trocas iônicas obteve-se zeólita 5A. A porcentagem de sódio trocada na zeólita final foi 61,4%.Zeolites synthesis as adsorbing materials requires accurate control of the variables. There are distinct process variables for obtaining specific desired types depending on each different kind of zeolite to be synthesized. This paper was aimed at obtaining NaA zeolites from kaolin in order to obtain zeolites A afterwards through ionic exchange with the previously synthesized zeolite. These zeolites can then be used as highly selective adsorbents to adsorb, for instance, heavy metals in industrial effluents. The results obtained were satisfactory, the methodology was efficient. From the commercial metakaolin used NaA zeolite was obtained successfully, and through ionic exchanges 5A zeolite was obtained. The exchangeable sodium percentage in the final zeolite was 61.4%.

  17. Production of highly charged ion beams from ECR ion sources

    International Nuclear Information System (INIS)

    Xie, Z.Q.

    1997-09-01

    Electron Cyclotron Resonance (ECR) ion source development has progressed with multiple-frequency plasma heating, higher mirror magnetic fields and better technique to provide extra cold electrons. Such techniques greatly enhance the production of highly charged ions from ECR ion sources. So far at cw mode operation, up to 300 eμA of O 7+ and 1.15 emA of O 6+ , more than 100 eμA of intermediate heavy ions for charge states up to Ar 13+ , Ca 13+ , Fe 13+ , Co 14+ and Kr 18+ , and tens of eμA of heavy ions with charge states to Kr 26+ , Xe 28+ , Au 35+ , Bi 34+ and U 34+ have been produced from ECR ion sources. At an intensity of at least 1 eμA, the maximum charge state available for the heavy ions are Xe 36+ , Au 46+ , Bi 47+ and U 48+ . An order of magnitude enhancement for fully stripped argon ions (I ≥ 60 enA) also has been achieved. This article will review the ECR ion source progress and discuss key requirement for ECR ion sources to produce the highly charged ion beams

  18. Production of highly ionized recoil ions in heavy ion impact

    International Nuclear Information System (INIS)

    Tawara, H.; Tonuma, T.; Be, S.H.; Shibata, H.; Kase, M.; Kambara, T.; Kumagai, H.; Kohno, I.

    1985-01-01

    The production mechanisms of highly ionized recoil ions in energetic, highly charged heavy ion impact are compared with those in photon and electron impact. In addition to the innershell ionization processes which are important in photon and electron impact, the electron transfer processes are found to play a key role in heavy ion impact. In molecular targets are also observed highly ionized monoatomic ions which are believed to be produced through production of highly ionized molecular ions followed by prompt dissociation. The observed N 6+ ions produced in 1.05MeV/amu Ar 12+ ions on N 2 molecules are produced through, for example, N 2 12+ *→N 6+ +N 6+ process. (author)

  19. Tissue molecular ion imaging by gold cluster ion bombardment.

    Science.gov (United States)

    Touboul, David; Halgand, Fréderic; Brunelle, Alain; Kersting, Reinhard; Tallarek, Elke; Hagenhoff, Birgit; Laprévote, Olivier

    2004-03-15

    The use of gold cluster focused ion beams produced by a liquid metal ion gun in a TOF-SIMS mass spectrometer is shown to dramatically enhance secondary ion emission of phospholipids and peptides. The method has been successfully tested with cells grown onto plastic slips and with mouse brain slices, without any treatment of the samples. Very reliable time-of-flight mass spectra are acquired with a low primary ion dose of a few 10(7) ions, and high lateral resolution molecular ion images are obtained for heavy ions of great biological interest. This approach offers new opportunities in pharmacological and biological research fields by localizing compounds of interest such as drugs or metabolites in tissues.

  20. A laser ablation ion source for the FRS ion catcher

    Energy Technology Data Exchange (ETDEWEB)

    Rink, Ann-Kathrin; Ebert, Jens; Petrick, Martin; Reiter, Pascal [Justus Liebig Universitaet Giessen (Germany); Dickel, Timo; Geissel, Hans; Plass, Wolfgang; Scheidenberger, Christoph [Justus Liebig Universitaet Giessen (Germany); GSI, Darmstadt (Germany); Purushothamen, Sivaji [GSI, Darmstadt (Germany)

    2013-07-01

    The FRS Ion Catcher was developed to serve as test bench for the low energy branch of the Super FRS to slow down exotic nuclei and prepare them for further measurements/ experiments. It consists of a cryogenic stopping cell to thermalise the ions, a diagnostic unit for stopping cell characterisation and various radiofrequency quadrupole structures to guide the ions to the Multiple-Reflection Time-of-Flight Mass Spectrometer for mass measurements, α spectroscopy and isobar separation. To characterise the extraction times of the stopping cell, which is one of the main performance parameters of such a cell, a laser ablation ion source has been develped and tested. This ion source provides a sharply defined starting point of the ions for the extraction time measurement. In the future this source will provide reference ions to calibrate the mass spectrometer for accurate mass measurements.

  1. Ion microtomography using ion time-of-flight

    International Nuclear Information System (INIS)

    Roberts, M.L.; Heikkinen, D.W.; Proctor, I.D.; Pontau, A.E.; Olona, G.T.; Felter, T.E.; Morse, D.H.; Hess, B.V.

    1992-01-01

    We have developed and are in the process of testing an ion time-of-flight (TOF) detector system for use in our ion microtomography measurements. Using TOF, ion energy is determined by measurement of the ion's flight time over a certain path length. For ion microtomography, the principle advantage of TOF analysis is that ion count rates of several hundred thousand counts per second can be achieved as compared to a limit of about ten thousand ions per second when using a solid-state silicon surface barrier detector and associated electronics. This greater than 10 fold increase in count rate correspondingly shortens sample analysis time or increases the amount of data that can be collected on a given sample. Details of the system and progress to date are described

  2. Design study of primary ion provider for relativistic heavy ion collider electron beam ion source.

    Science.gov (United States)

    Kondo, K; Kanesue, T; Tamura, J; Okamura, M

    2010-02-01

    Brookhaven National Laboratory has developed the new preinjector system, electron beam ion source (EBIS) for relativistic heavy ion collider (RHIC) and National Aeronautics and Space Administration Space Radiation Laboratory. Design of primary ion provider is an essential problem since it is required to supply beams with different ion species to multiple users simultaneously. The laser ion source with a defocused laser can provide a low charge state and low emittance ion beam, and is a candidate for the primary ion source for RHIC-EBIS. We show a suitable design with appropriate drift length and solenoid, which helps to keep sufficient total charge number with longer pulse length. The whole design of primary ion source, as well as optics arrangement, solid targets configuration and heating about target, is presented.

  3. Ion bipolar junction transistors.

    Science.gov (United States)

    Tybrandt, Klas; Larsson, Karin C; Richter-Dahlfors, Agneta; Berggren, Magnus

    2010-06-01

    Dynamic control of chemical microenvironments is essential for continued development in numerous fields of life sciences. Such control could be achieved with active chemical circuits for delivery of ions and biomolecules. As the basis for such circuitry, we report a solid-state ion bipolar junction transistor (IBJT) based on conducting polymers and thin films of anion- and cation-selective membranes. The IBJT is the ionic analogue to the conventional semiconductor BJT and is manufactured using standard microfabrication techniques. Transistor characteristics along with a model describing the principle of operation, in which an anionic base current amplifies a cationic collector current, are presented. By employing the IBJT as a bioelectronic circuit element for delivery of the neurotransmitter acetylcholine, its efficacy in modulating neuronal cell signaling is demonstrated.

  4. Trapped Ion Qubits

    Energy Technology Data Exchange (ETDEWEB)

    Maunz, Peter Lukas Wilhelm

    2017-04-01

    Qubits can be encoded in clock states of trapped ions. These states are well isolated from the environment resulting in long coherence times [1] while enabling efficient high-fidelity qubit interactions mediated by the Coulomb coupled motion of the ions in the trap. Quantum states can be prepared with high fidelity and measured efficiently using fluorescence detection. State preparation and detection with 99.93% fidelity have been realized in multiple systems [1,2]. Single qubit gates have been demonstrated below rigorous fault-tolerance thresholds [1,3]. Two qubit gates have been realized with more than 99.9% fidelity [4,5]. Quantum algorithms have been demonstrated on systems of 5 to 15 qubits [6–8].

  5. Negative ion sourcery

    International Nuclear Information System (INIS)

    Os, C.F.A. van.

    1989-01-01

    The work described in this thesis is involved by current research programs in the field of nuclear-fusion. A brief introduction to fusion is given, anticipated problems related to current drive of the fusion plasma are pinpointed and probable suggestions to overcome these problems are described. One probable means for current drive is highlighted; Neutral Beam Injection (NBI). This is based on injecting a 1 MeV neutral hydrogen or deuterium beam into a fusion plasma. Negative ions are needed as primary particles because they can easily be neutralized at 1 MeV. The two current schemes for production of negative ions are described, volume production and negative surface ionization. The latter method is extensively studied in this thesis. (author). 171 refs.; 55 figs.; 7 tabs

  6. Experimental Evaluation of a Negative Ion Source for a Heavy Ion Fusion Negative Ion Driver

    Energy Technology Data Exchange (ETDEWEB)

    Grisham, L. R.; Hahto, S. K.; Hahto, S. T.; Kwan, J. W.; Leung, K. N.

    2004-06-16

    Negative halogen ions have recently been proposed as a possible alternative to positive ions for heavy ion fusion drivers because electron accumulation would not be a problem in the accelerator, and if desired, the beams could be photo-detached to neutrals. To test the ability to make suitable quality beams, an experiment was conducted at Lawrence Berkeley National Laboratory using chlorine in an RF-driven ion source. Without introducing any cesium (which is required to enhance negative ion production in hydrogen ion sources) a negative chlorine current density of 45 mA/cm{sup 2} was obtained under the same conditions that gave 57 45 mA/cm{sup 2} of positive chlorine, suggesting the presence of nearly as many negative ions as positive ions in the plasma near the extraction plane. The negative ion spectrum was 99.5% atomic chlorine ions, with only 0.5% molecular chlorine, and essentially no impurities. Although this experiment did not incorporate the type of electron suppression technology that i s used in negative hydrogen beam extraction, the ratio of co-extracted electrons to Cl{sup -} was as low as 7 to 1, many times lower than the ratio of their mobilities, suggesting that few electrons are present in the near-extractor plasma. This, along with the near-equivalence of the positive and negative ion currents, suggests that the plasma in this region was mostly an ion-ion plasma. The negative chlorine current density was relatively insensitive to pressure, and scaled linearly with RF power. If this linear scaling continues to hold at higher RF powers, it should permit current densities of 100 45 mA/cm{sup 2}, sufficient for present heavy ion fusion injector concepts. The effective ion temperatures of the positive and negative ions appeared to be similar and relatively low for a plasma source.

  7. Ion funnel device

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Yehia M.; Chen, Tsung-Chi; Harrer, Marques B.; Tang, Keqi; Smith, Richard D.

    2017-11-21

    An ion funnel device is disclosed. A first pair of electrodes is positioned in a first direction. A second pair of electrodes is positioned in a second direction. The device includes an RF voltage source and a DC voltage source. A RF voltage with a superimposed DC voltage gradient is applied to the first pair of electrodes, and a DC voltage gradient is applied to the second pair of electrodes.

  8. Ion optics for accelerators

    International Nuclear Information System (INIS)

    Enge, H.A.

    1974-01-01

    A review is given of ion-optic devices used in particle accelerators, including electrostatic lenses, magnetic quadrupoles, and deflecting magnets. Tube focusing in dc accelerators is also treated, and a novel scheme for shaping the electrodes to produce strong focusing is described. The concepts of emittance (phase space) and emittance conservation are briefly discussed. Chromatic and spatial aberrations are introduced, and it is shown how they can be calculated and sometimes substantially reduced. Some examples are given

  9. Heavy ion fusion III

    International Nuclear Information System (INIS)

    Hammer, D.; Max, C.; Perkins, F.; Rosenbluth, M.

    1987-03-01

    This report updates Heavy Ion Fusion, JSR-82-302, dated January, 1983. During the last four years, program management and direction has been changed and the overall Inertial Confinement Program has been reviewed. This report therefore concentrates on accelerator physics issues, how the program has addressed those issues during the last four years, and how it will be addressing them in the future. 8 refs., 3 figs

  10. Collective Ion Acceleration.

    Science.gov (United States)

    1980-01-01

    flash x- _ ray sources may require, for maximum x-ray yield. t Pulsed-power systems using Van de Graaff generators are also in use. They are less common... generation and collective ion acceleration. A more recent effort has been initi- II ated to investigate proton acceleration in Induction Linacs. The...original contract supported the study of microwave generation using slow wave structures and study of a free electron laser configuration. About 1 alfway

  11. Relativistic heavy ion reactions

    International Nuclear Information System (INIS)

    Brink, D.M.

    1989-08-01

    The theory of quantum chromodynamics predicts that if nuclear matter is heated to a sufficiently high temperature then quarks might become deconfined and a quark-gluon plasma could be produced. One of the aims of relativistic heavy ion experiments is to search for this new state of matter. These lectures survey some of the new experimental results and give an introduction to the theories used to interpret them. 48 refs., 4 tabs., 11 figs

  12. Cancer therapy with ions

    International Nuclear Information System (INIS)

    Mandrillon, P.

    1993-01-01

    The treatment of tumours with charged particles, ranging from protons to 'light ions' (Carbon, Oxygen, Neon) has many advantages, but up to now has been little used because of the absence of facilities. After the successful pioneering work carried out with accelerators built for physics research, machines dedicated to this new radiotherapy are planned or already in construction. The rationale for this new radiotherapy, the accelerators and the beam delivery systems needed are presented in this paper. (orig.)

  13. Secondary ion mass spectroscopy

    International Nuclear Information System (INIS)

    Sroubek, Z.; Zavadil, J.; Kubec, F.

    1977-01-01

    Secondary ion mass spectroscopy is one of the modern methods suitable for the analysis of thin films and solid state surfaces. The method is capable of providing the compositional information with a depth resolution below 0.1 μm and a sensitivity of the order of 10 -3 ppm for some impurities. The review article contains a description of the method, a list of typical applications and a short account of relevant theories. (author)

  14. Small size ion pumps

    International Nuclear Information System (INIS)

    Cyranski, R.; Kiliszek, Cz.R.; Marks, J.; Sobolewski, A.; Magielko, H.

    2001-01-01

    This paper describes some designs of the two versions ion pumps and their range operation for various magnetic fields. The first version is made with different cell size in the anode element and titanium cathode operating in magnetic field from 600 to 650 Gs and the second version with the same anode element but differential Ti/Ta cathode working in magnetic field above 1200 Gs

  15. para mejorar el %R

    Directory of Open Access Journals (Sweden)

    Alfredo Díaz Mata

    2001-01-01

    Full Text Available En este trabajo se revisan dos indicadores técnicos bursátiles que están estrechamente relacionados, el oscilador estocástico %K de Lane y el oscilador %R de Williams; asimismo, se evalúa el uso de dos mecanismos asociados con el primero y que no suelen utilizarse con el %R: el proceso de frenado (slowing y el uso de un promedio móvil del propio oscilador estocástico como disparadores de señales de compra y de venta. Realizando simulaciones con 27 acciones y el Índice de Precios y Cotizaciones de la Bolsa Mexicana de Valores se verifica la hipótesis principal y se comprueba que, efectivamente, en muchos casos, el uso del proceso de frenado con el oscilador %R de Williams permite tomar mejores decisiones. Por otro lado, se concluye que de los dos disparadores de señales el que mejor funciona, tanto para %K como para %R es el uso de cotas inferior y superior. Este artículo surgió en el curso de una investigación sobre el análisis técnico bursátil de acciones que se puede realizar en su totalidad por computadora y que, esencialmente, excluye el análisis gráfico. Uno de los propósitos del estudio es determinar si es posible, y bajo qué mecanismos, establecer un sistema de análisis bursátil que le permita al inversionista tomar decisiones de inversión en acciones en la Bolsa Mexicana de Valores sin tener que emplear la considerable cantidad de tiempo que es necesario para el análisis gráfico tradicional. Durante este estudio se realizó un análisis preliminar de unos 120 indicadores técnicos para, por un lado, conocerlos con cierto detalle y, por otra parte, aislar aquellos que prometían ser de utilidad para el objetivo de la investigación. Fue en este proceso cuando se detectó que existen dos indicadores que están relacionados y que permiten un análisis por separado que tiene, cuando menos, dos ventajas. En primer lugar está el placer que da a quien gusta de estos temas encontrarse con indicadores que, de acuerdo

  16. Inmunopotenciadores para la acuicultura

    Directory of Open Access Journals (Sweden)

    Rocmira Pérez

    2014-04-01

    Full Text Available La acuicultura es una de las actividades económicas de mayor crecimiento para la producción de alimentos. Uno de sus principales retos es la obtención de grandes volúmenes de producción con la mayor calidad posible. Esto conlleva a una reducción de la aplicación de antibióticos y productos quimioterapéuticos. Una de las estrategias más prometedoras es la aplicación de inmunopotenciadores, principalmente en los cultivos intensivos. El objetivo de este trabajo fue revisar los principales inmunopotenciadores, así como las tendencias y retos de su uso mundial. Se resumen las particularidades moleculares y funcionales de los mismos y se hace énfasis en los más estudiados: levamisol, ß-glucanos, lipopolisacárido, vitamina C, extractos de plantas y hormonas. Todos estos compuestos de naturaleza heterogénea inciden mayoritariamente en los componentes de la inmunidad innata de los peces, fortaleciendo y potenciando la resistencia a enfermedades; adicionalmente algunos de ellos tienen funciones antiestrés y favorecen su crecimiento. Se concluye que los inmunopotenciadores constituyen una estrategia viable para reducir las pérdidas por problemas sanitarios en el sector de la acuicultura; pero aún quedan por solucionar aspectos como la vía de administración y la etapa de inmunización adecuada para cada especie y tipo de cultivo.

  17. Fluorine negative ion detachment kinetics

    Science.gov (United States)

    Burke, R. R.; Miller, W. J.; Gould, R. K.

    1971-01-01

    A study of the rate of F(-) detachment by O and H atoms via the reactions F(-) + O yields FO + e and F(-) + H yields FH+ e was undertaken using a drift tube to produce F(-) ions at various drift velocities and therefore different ion temperatures. Preliminary mobility measurements of F(-) ions in Ar were made, indicating that ion temperatures in the 300 K to 5000 K range could be achieved; however due to numerous difficulties experienced in obtaining a reliable F(-) ion source, the study could not be completed.

  18. Ion sources for medical accelerators

    Science.gov (United States)

    Barletta, W. A.; Chu, W. T.; Leung, K. N.

    1998-02-01

    Advanced injector systems for proton synchrotrons and accelerator-based boron neutron capture therapy systems are being developed at the Lawrence Berkeley National Laboratory. Multicusp ion sources, particularly those driven by radio frequency, have been tested for these applications. The use of a radio frequency induction discharge provides clean, reliable, and long-life source operation. It has been demonstrated that the multicusp ion source can provide good-quality positive hydrogen ion beams with a monatomic ion fraction higher than 90%. The extractable ion current densities from this type of source can meet the injector requirements for both proton synchrotron and accelerator-based boron neutron capture therapy projects.

  19. Recent progress in ion sources

    International Nuclear Information System (INIS)

    Osher, J.E.

    1975-01-01

    This paper is intended to survey recent developments in ion sources, particularly work reported at the ''Symposium on Ion Sources and the Formation of Ion Beams'' held in Berkeley in October 1974. The approach here will be to subdivide this topic into three main areas; briefly list and discuss notable progress in each; and finally add some additional detail through a few specific, selected examples. The major items of progress discussed include development of large-area plasma surfaces for multiple- aperture ion sources, a significant increase in available negative-ion current densities, and improved general agreement between extraction electrode design and performance. (U.S.)

  20. High energy ion microprobes

    International Nuclear Information System (INIS)

    Nobiling, R.

    1983-01-01

    Analysis with high energy ion beams can be applied to microscopic samples or substructures of complex specimens by using nuclear or proton microprobes. Focusing of high energy ion beams requires specially designed collimators and lens systems. At present, beam diameters of 1 μm are obtained. The lateral resolution of the instruments, however, is not limited to this 1 μm. Consequently microprobe analysis with ion beams in favourable cases can provide better analytical possibilities and lateral resolution as compared with electron microprobes. Due to aberrations an improvement of beam diameters to less than 0.5-1 μm requires compensation of at least the chromatic aberration. The most important fields of application are mineralogy, materials science and biology. With nuclear reactions and PIXE (particle induced X-ray emission) the whole periodic table can be measured with detection limits down to the ppm level (weight fraction). The virtual lack of beam broadening by scattering in samples of a few μm thickness makes a kind of microscopic chemical tomography possible. (orig.)

  1. Novel laser ion sources

    CERN Document Server

    Fournier, P; Kugler, H; Lisi, N; Scrivens, R; Rodríguez, F V; Düsterer, S; Sauerbrey, R; Schillinger, H; Theobald, W; Veisz, L; Tisch, J W G; Smith, R A

    2000-01-01

    Development in the field of high-power laser systems with repetition rates of several Hz and energies of few joules is highly active and opening, giving new possibilities for the design of laser ions sources. Preliminary investigations on the use of four different laser and target configurations are presented: (1) A small CO/sub 2/ laser (100 mJ, 10.6 mu m) focused onto a polyethylene target to produce C ions at 1 Hz repetition rate (CERN). (2) An excimer XeCl laser (6 J, 308 nm) focused onto solid targets (Frascati). (3) A femtosecond Ti: sapphire laser (250 mJ, 800 nm) directed onto a solid targets (Jena). (4) A picosecond Nd: yttrium-aluminum-garnet (0.3 J, 532 nm) focused into a dense medium of atomic clusters and onto solid targets (London). The preliminary experimental results and the most promising schemes will be discussed with respect to the scaling of the production of high numbers of highly charged ions. Different lasers are compared in terms of current density at 1 m distance for each charge state...

  2. Ion channeling revisited

    Energy Technology Data Exchange (ETDEWEB)

    Doyle, Barney Lee [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Corona, Aldo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Nguyen, Anh [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    A MS Excel program has been written that calculates accidental, or unintentional, ion channeling in cubic bcc, fcc and diamond lattice crystals or polycrystalline materials. This becomes an important issue when simulating the creation by energetic neutrons of point displacement damage and extended defects using beams of ions. All of the tables and graphs in the three Ion Beam Analysis Handbooks that previously had to be manually looked up and read from were programed into Excel in handy lookup tables, or parameterized, for the case of the graphs, using rather simple exponential functions with different powers of the argument. The program then offers an extremely convenient way to calculate axial and planar half-angles and minimum yield or dechanneling probabilities, effects on half-angles of amorphous overlayers, accidental channeling probabilities for randomly oriented crystals or crystallites, and finally a way to automatically generate stereographic projections of axial and planar channeling half-angles. The program can generate these projections and calculate these probabilities for axes and [hkl] planes up to (555).

  3. Democracia para ciudadanos ciborgs

    Directory of Open Access Journals (Sweden)

    Juan Varela

    2007-07-01

    Full Text Available Enumera los instrumentos imprescindibles de la ciberpolítica para campañas electorales en España, cuando se renovaron los cargos municipales. La política vuelve a ser personal cuando ciudadanos y políticos se hablan cara a cara y cita varios ejemplos, reconociendo la recuperación de la comunicación directa. La ciberdemocracia es muy exigente. Los políticos prefieren la magia de la imagen. La sociedad no sabe como detener la propaganda viral que bombardea a los buscadores de red.

  4. Para pensar o afeto

    Directory of Open Access Journals (Sweden)

    Aluisio Pereira de Menezes

    Full Text Available Apresentação de um conjunto de formulações relativas ao “afeto” anteriores ao surgimento da psicanálise. Dificuldade da psicanálise em construir uma concepção propriamente psicanalítica. Contribuição da fenomenologia de Husserl para o estudo do afeto. Atualidade das concepções do afeto marcadas pelas neurociências. As maneiras principais de ver o problema da conceituação do afeto no pensamento psicanalítico.

  5. Nombrados para el mal

    OpenAIRE

    Lara, Claudio; Sanchez, Mariela

    2011-01-01

    El presente trabajo se encuentra inscripto en la investigación Las vicisitudes del lazo amoroso en la época actual en el Gran La Plata. En ella, nuestro rasgo de investigación fue establecer algunas coordenadas para pensar que los signos de la Declinación del Nombre del Padre deben leerse en la transformación del registro del amor, dejando por fuera el registro que más desarrollos ha tenido dentro del campo del psicoanálisis: el de los ideales y el de la autoridad. La propuesta es que si El n...

  6. Bullying: Conhecer para Prevenir

    OpenAIRE

    Elisabete Fernandes; Sónia Henriques; Susana Mendes; Esperança Ribeiro

    2016-01-01

    O bullying é um fenómeno que suscita a apreensão de toda a sociedade. Deste modo, enquanto pais, educadores e profissionais, devemos reconhecer que a violência entre pares em meio escolar afeta gravemente o desenvolvimento saudável das crianças. Conhecer e identificar as causas que estão na origem do bullying, bem como as consequências que este comportamento acarreta no desenvolvimento psicossocial dos seus alvos, é fundamental para melhor intervir. Proteger as crianças e jovens de hoje contr...

  7. Paisajismo para La Reserva

    OpenAIRE

    Fernández,Teodoro

    2004-01-01

    El paisaje de Santiago está fuertemente determinado por el ejercicio de una voluntad. En un secano, con cuatro meses lluviosos y una sequía larga, los santiaguinos han construido a través de los años un jardín de riego soportado por múltiples dispositivos: acequias, canales, pozos y estanques. Es posible inaugurar para la ciudad otra manera de ejercer esa voluntad de paisaje: no una transformación impositiva, sino la comprensión de los procesos y relaciones naturales entre lluvia, torrentes, ...

  8. Cristalizadores para soro concentrado

    OpenAIRE

    TULER PERRONE, Italo; Simeão, Moise; Schuck, Pierre; Stephani, Rodrigo; De Carvahlo, Antonio Fernandes

    2016-01-01

    Na industria de secagem de lacteos observa-se que a secagem do soro é mais complicada do que a secagem do leite. São frequentes as adesões dentro do spray dryer, ciclones e tubulações, assim como o empedramento do produto durante o processamento ou durante a estocagem e o transporte. Ao buscarmos mecanismos para maior controle e padronização da tecnologia de produção do soro em pó nos deparamos com diversos requisitos de qualidade como: acidez e pH do soro, microbiota contaminante, teor de sa...

  9. Ion Acceleration Inside Foreshock Transients

    Science.gov (United States)

    Liu, Terry Z.; Lu, San; Angelopoulos, Vassilis; Lin, Yu; Wang, X. Y.

    2018-01-01

    Recent observations upstream of Earth's bow shock have revealed that foreshock transients can not only accelerate solar wind ions by reflection at their upstream boundaries but may also accelerate ions inside them. Evidence for the latter comes from comparisons of ion spectra inside and outside the cores, and from evidence of leakage of suprathermal ions from the cores. However, definite evidence for, and the physics of, ion acceleration in the foreshock transients are still open questions. Using case studies of foreshock transients from Time History of Events and Macroscale Interactions during Substorms observations, we reveal an ion acceleration mechanism in foreshock transients that is applicable to 25% of the transients. The ion energy flux is enhanced between several keV to tens of keV in the cores. We show that these energetic ions are reflected at the earthward moving boundary of foreshock transients, are accelerated through partial gyration along the convection electric field, and can leak out both upstream and downstream of the foreshock transients. Using ions moving self-consistently with a generic 3-D global hybrid simulation of a foreshock transient, we confirm this physical picture of ion acceleration and leakage. These accelerated ions could be further accelerated at the local bow shock and repopulate the foreshock, increasing the efficacy of solar wind-magnetosphere interactions.

  10. Resonance Ionization Laser Ion Sources

    CERN Document Server

    Marsh, B

    2013-01-01

    The application of the technique of laser resonance ionization to the production of singly charged ions at radioactive ion beam facilities is discussed. The ability to combine high efficiency and element selectivity makes a resonance ionization laser ion source (RILIS) an important component of many radioactive ion beam facilities. At CERN, for example, the RILIS is the most commonly used ion source of the ISOLDE facility, with a yearly operating time of up to 3000 hours. For some isotopes the RILIS can also be used as a fast and sensitive laser spectroscopy tool, provided that the spectral resolution is sufficiently high to reveal the influence of nuclear structure on the atomic spectra. This enables the study of nuclear properties of isotopes with production rates even lower than one ion per second and, in some cases, enables isomer selective ionization. The solutions available for the implementation of resonance laser ionization at radioactive ion beam facilities are summarized. Aspects such as the laser r...

  11. A review of polarized ion sources

    International Nuclear Information System (INIS)

    Schmor, P.W.

    1995-06-01

    The two main types of polarized ion sources in use on accelerators today are the Atomic Beam Polarized Ion Source (ABIS) source and the Optically Pumped Polarized Ion Source (OPPIS). Both types can provide beams of nuclearly polarized light ions which are either positively or negatively charged. Heavy ion polarized ion sources for accelerators are being developed. (author). 35 refs., 1 tab

  12. ION SOURCES FOR ENERGY EXTREMES OF ION IMPLANTATION.

    Energy Technology Data Exchange (ETDEWEB)

    HERSCHCOVITCH,A.; JOHNSON, B.M.; BATALIN, V.A.; KROPACHEV, G.N.; KUIBEDA, R.P.; KULEVOY, T.V.; KOLOMIETS, A.A.; PERSHIN, V.I.; PETRENKO, S.V.; RUDSKOY, I.; SELEZNEV, D.N.; BUGAEV, A.S.; GUSHENETS, V.I.; LITOVKO, I.V.; OKS, E.M.; YUSHKOV, G. YU.; MASEUNOV, E.S.; POLOZOV, S.M.; POOLE, H.J.; STOROZHENKO, P.A.; SVAROVSKI, YA.

    2007-08-26

    For the past four years a joint research and development effort designed to develop steady state, intense ion sources has been in progress with the ultimate goal to develop ion sources and techniques, which meet the two energy extreme range needs of mega-electron-volt and 100's of electron-volt ion implanters. This endeavor has already resulted in record steady state output currents of high charge state of Antimony and Phosphorous ions: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb{sup 4+}, Sb{sup 5+}, and Sb{sup 6+} respectively. For low energy ion implantation our efforts involve molecular ions and a novel plasmaless/gasless deceleration method. To date, 1 emA of positive Decaborane ions were extracted at 10 keV and smaller currents of negative Decaborane ions were also extracted. Additionally, Boron current fraction of over 70% was extracted from a Bemas-Calutron ion source, which represents a factor of 3.5 improvement over currently employed ion sources.

  13. "Colaborar para Competir"

    Directory of Open Access Journals (Sweden)

    Martha Liliana Hijuelos-Cárdenas

    2015-06-01

    Full Text Available De acuerdo con Michael Porter, los Clusters se definen como “Una agrupación de empresas e instituciones relacionadas entre sí, pertenecientes a un mismo sector o segmento de mercado, que se encuentran próximas geográficamente y que colaboran para ser más competitivas”. Los Clusters son en última instancia una herramienta de competitividad basada en la cooperación de sus miembros, y es una de las estrategias recientes, en el país, para incrementar la productividad y competitividad y las apuestas productivas desde el nivel local. Y es precisamente esta cercanía geográfica de las empresas de un mismo sector, lo que a la vez que genera la competencia entre ellas, también les facilita el acceso a insumos y a conocimientos específicos y en última instancia les permite promover la innovación.

  14. Principios teatrales para docentes

    Directory of Open Access Journals (Sweden)

    R. Irene Arroyo Zúñiga

    2005-01-01

    Full Text Available Este trabajo pretende dar herramientas a los docentes para que puedan utilizarlas como parte de las actividades dentro de un plan de elección, en cualquier disciplina. Además encontrará una exposición de los elementos que componen el arte de la representación escénica, como son: 1. Expresión corporal; es la capacidad de expresar emociones partiendo únicamente de nuestro cuerpo. 2. Impostación; es la habilidad de proyectar la voz sin lastimar las cuerdas vocales. 3. Dicción; es la pronunciación correcta de las palabras. 4. Actuación; es la posibilidad de crear un personaje partiendo de los recursos expresivos y de la forma natural en que el alumno acostumbra a reaccionar. Técnica de improvisación, en éste artículo propongo una serie de seis pasos que pueden ser de gran ayuda a la hora de usar el teatro como recurso didáctico. El teatro a lo largo de la historia ha sido usado para transmitir conocimientos, valores, creencias y todo aspecto inherente a los individuos y su entorno social. Por lo tanto debemos aprovechar al máximo los beneficios que nos ofrece el teatro como educadores

  15. para las lenguas

    Directory of Open Access Journals (Sweden)

    Manuel Tost Planet

    2005-01-01

    Full Text Available La publicación del Marco común europeo de referencia para las lenguas, del Consejo de Europa –aún poco conocido en nuestro país– está teniendo ya una notable influencia en todos los ámbitos de la enseñanza de las lenguas y de un modo particular en la elaboración de materiales de nueva generación para el aprendizaje de las lenguas extranjeras. Tras presentar elementos contextuales de la situación del FLE en nuestro país, que tienen, pensamos, una cierta relevancia, en esta contribución se describen precisamente algunos aspectos fragmentarios de dicho Marco y se evocan, por último, los principales ejes en torno a los cuales se mueve la actual innovación didáctica, en lo que se refiere más concretamente a las actividades de aprendizaje en el aula de idiomas.

  16. Serie: Madera para construcción Acabados para madera

    OpenAIRE

    Sáenz-Muñoz, Marta

    2012-01-01

    Durante mucho tiempo, la madera ha sido utilizada como material de construcción para resolver principalmente objetivos estructurales; sin embargo, actualmente, el uso de la madera ha tomado mucho auge en la estética de las construcciones, para brindar apariencia y calidez. En la actualidad, el mercado ofrece una amplia gama productos para dar diversos “acabados” a la madera, los cuales sirven para resaltar la belleza de algunas de ellas, realzar características como el color y la veta, o bien...

  17. Study on the thermoluminescent properties of K{sub 2}YF{sub 5} and K{sub 2}GdF{sub 5} crystals doped with optically active trivalent ions for gamma and neutrons dosimetry; Estudo das propriedades termoluminescentes de cristais de K{sub 2}YF{sub 5} e K{sub 2}GdF{sub 5} dopados com ions trivalentes opticamente ativos para dosimetria gama e de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Edna Carla da

    2008-07-01

    In this work, the thermoluminescent (TL) properties of both double potassium yttrium fluoride (K{sub 2}YF{sub 5}) and double potassium gadolinium fluoride (K{sub 2}GdF{sub 5}) crystals doped with optically active rare earth ions were investigated from the point of view of gamma and neutron dosimetry. Crystalline platelets with thickness of about 1 mm, synthesized under hydrothermal conditions, were irradiated in order to study TL sensitivity, as well as dose and energy response, reproducibility and fading, in terms of Ce{sup 3+}, Tb{sup 3+}, Dy{sup 3+}, e Pr{sup 3+} concentrations. The K{sub 2}YF{sub 5} crystals doped with 1.0 at por cent Dy{sup 3+} have been found to have an excellent linear TL response to X and gamma photons, in the range of 0.01 to 10 mGy. The TL output is comparable to that of CaS0{sub 4}:Mn dosemeters. The main peak at 130 deg C has been found to have a TL response for 41.1 keV X-ray energy 32 times higher than that for 662 keV gamma rays. This fact points out that the K{sub 2}Y{sub 0.99}Dy{sub 0.01}F{sub 5} crystals have great potential for X-rays diagnostic and/or industrial radiography. On the other hand, the K{sub 2}GdF{sub 5} crystals doped with 5.0 at por cent Dy{sup 3+} have been found to have the better TL response for gamma and fast neutron radiation, among the dopants studied. For gamma fields the TL response was linear for doses ranging from 0.1 to 200 mGy. The TL peak around 200 deg C can be deconvoluted into four individual peaks, all of them with linear behavior. For fast neutron radiation produced by an {sup 241}Am{sub B}e source, the TL responses for doses ranging from 0.6 to 12 mSv were also linear and comparable to that of commercial TLD-600, irradiated at same conditions. The TL emission due to neutrons was in the high temperature range, above 200 deg C. These results points out that K{sub 2}Gd{sub 0.95}Dy{sub 0.05}F{sub 5} crystals are good candidates for use in neutron dosimetry applications. (author)

  18. Thermoluminescent dosemeters characterization for patient dosimetry in diagnostic radiology preliminary results;Caracterizacao de dosimetros termoluminescentes para dosimetria de pacientes em radiodiagnostico - resultados iniciais

    Energy Technology Data Exchange (ETDEWEB)

    Castro, William J.; Squair, Peterson L. [Faculdade Novo Rumo, Belo Horizonte, MG (Brazil); Centro de Desenvolvimento de Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Gonzaga, Natalia B. [Universidade Unincor, Belo Horizonte, MG (Brazil); Centro de Desenvolvimento de Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Nogueira, Maria S.; Silva, Teogenes A. da [Centro de Desenvolvimento de Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2009-07-01

    The determination of the metrological characteristics of thermoluminescent (TL) dosimeters plays an important role in dosimetry of patients submitted to x-ray examinations for diagnostic purpose. Entrance surface doses can be measured with TL dosimeters to verify the compliance with the diagnostic reference levels. Organ doses can be estimated through TL measurements in an anthropomorphic phantom which it allows the radiation risk assessment. In this work, LiF:Mg,Ti (TLD-100) rod and chip thermoluminescent dosimeters were characterized considering their use for patient dosimetry in computerized tomography and mammography. Preliminary results showed that TL dosimeters have a response reproducibility of 7.8% and 4.8% and homogeneity of 18.4% and 6.5% for rod and chip shapes, respectively. (author)

  19. Synthesis and characterization of inorganic ion exchangers based on mixed oxide tin-titanium to be used in recovery of cadmium and nickel and photoluminescent studies; Sintese e caracterizacao de trocadores ionicos inorganicos a base de oxidos mistos estanho-titanio para utilizacao na recuperacao de cadmio e niquel e estudos fotoluminescentes

    Energy Technology Data Exchange (ETDEWEB)

    Paganini, Paula Pinheiro

    2007-07-01

    This work presents the synthesis, characterization and adsorption studies of inorganic ion exchangers based on mixed tin-titanium oxide for recovery of cadmium and nickel metals from aqueous effluents, discarded in the environment mainly through Ni-Cd battery. The exchangers were synthesized by sol-gel modified method using a mixture of tin(IV) chloride and titanium(III) chloride and ammonium hydroxide, as precursors reagents. The materials obtained: SnO{sub 2}/TiO{sub 2} and SnO{sub 2}/TiO{sub 2}:Eu{sup 3+} were characterized by infrared spectroscopy, thermal analysis, scattering electronic microscopy (SEM), X-ray powder diffraction (XRD) (powder method) and electronic spectroscopy (excitation and emission) for the europium doped exchanger. The same materials also were synthesized in polymeric matrix too and can be used in column, because the synthesized materials showed crystals size in nano metric scale. It was determined by the distribution ratios for metals taking as parameters the influence of pH, the concentration of metals (by adsorption isotherms) and the contact time (by adsorption kinetic). The inorganic ion exchanger presented high exchange capacity with adsorption percent above 90 por cent for the studied conditions, quickly kinetic, heterogeneous exchange surfaces, physic adsorption and spontaneous process of exchange. To the doped exchanger spectroscopy properties were studied and also it was calculated the intensity parameters and it was found a satisfactory quantum yield. (author)

  20. Charge Breeding of Radioactive Ions

    CERN Document Server

    Wenander, F J C

    2013-01-01

    Charge breeding is a technique to increase the charge state of ions, in many cases radioactive ions. The singly charged radioactive ions, produced in an isotope separator on-line facility, and extracted with a low kinetic energy of some tens of keV, are injected into a charge breeder, where the charge state is increased to Q. The transformed ions are either directed towards a dedicated experiment requiring highly charged ions, or post-accelerated to higher beam energies. In this paper the physics processes involved in the production of highly charged ions will be introduced, and the injection and extraction beam parameters of the charge breeder defined. A description of the three main charge-breeding methods is given, namely: electron stripping in gas jet or foil; external ion injection into an electron-beam ion source/trap (EBIS/T); and external ion injection into an electron cyclotron resonance ion source (ECRIS). In addition, some preparatory devices for charge breeding and practical beam delivery aspects ...

  1. Cobalt alloy ion sources for focused ion beam implantation

    Energy Technology Data Exchange (ETDEWEB)

    Muehle, R.; Doebeli, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Zimmermann, P. [Eidgenoessische Technische Hochschule, Zurich (Switzerland)

    1997-09-01

    Cobalt alloy ion sources have been developed for silicide formation by focused ion beam implantation. Four eutectic alloys AuCo, CoGe, CoY and AuCoGe were produced by electron beam welding. The AuCo liquid alloy ion source was investigated in detail. We have measured the emission current stability, the current-voltage characteristics, and the mass spectrum as a function of the mission current. (author) 1 fig., 2 refs.

  2. Positive ion irradiation facility

    International Nuclear Information System (INIS)

    Braby, L.A.

    1985-01-01

    Many questions about the mechanisms of the response of cells to ionizing radiation can best be investigated using monoenergetic heavy charged particle beams. Questions of the role of different types of damage in the LET effect, for example, are being answered by comparing repair kinetics for damage induced by electrons with that produced by helium ions. However, as the models become more sophicated, the differences between models can be detected only with more precise measurements, or by combining high- and low-LET irradiations in split-dose experiments. The design of the authors present cell irradiation beam line has limited the authors to irradiating cells in a partial vacuum. A new way to mount the dishes and bring the beam to the cells was required. Several means of irradiating cells in mylar-bottom dishes have been used at other laboratories. For example at the RARAF Facility, the dual ion experiments are done with the dish bottom serving as the beam exit window but the cells are in a partial vacuum to prevent breaking the window. These researchers have chosen instead to use the dish bottom as the beam window and to irradiate the entire dish in a single exposure. A special, very fast pumping system will be installed at the end of the beam line. This system will make it possible to irradiate cells within two minutes of installing them in the irradiation chamber. In this way, the interaction of electron and ion-induced damage in Chlamydomonas can be studied with time between doses as short as 5 minutes

  3. Paramagnetism in ion-implanted oxides

    CERN Document Server

    Mølholt, Torben Esmann; Gíslason, Hafliði Pétur; Ólafsson, Sveinn

    This thesis describes the investigation on para-magnetism in dilute ion-implanted single-crystal oxide samples studied by on- and off-line $^{57}$Fe emission Mössbauer spectroscopy. The ion-implantation of the radioactive isotopes ( $^{57}$Mn and $^{57}$Co) was performed at the ISOLDE facility at CERN in Geneva, Switzerland. The off-line measurements were performed at Aarhus University, Denmark. Mössbauer spectroscopy is a unique method, giving simultaneously local information on valence/spin state of the $^{57}$Fe probe atoms, site symmetry and magnetic properties on an atomic scale. The utilisation of emission Mössbauer spectroscopy opens up many new possibilities compared with traditional transmission Mössbauer spectroscopy. Among them is the possibility of working with a low concentration below 10$^{-4}$ –10$^{-3}$ at.%, where the implanted Mössbauer $^{57}$Fe probes are truly dilute impurities exclusively interacting with their nearest neighbours and therefore the possibility of crea...

  4. Contact ionization ion source

    International Nuclear Information System (INIS)

    Hashmi, N.; Van Der Houven Van Oordt, A.J.

    1975-01-01

    An ion source in which an apertured or foraminous electrode having a multiplicity of openings is spaced from one or more active surfaces of an ionisation electrode, the active surfaces comprising a material capable of ionising by contact ionization a substance to be ionized supplied during operation to the active surface or surfaces comprises means for producing during operation a magnetic field which enables a stable plasma to be formed in the space between the active surface or surfaces and the apertured electrode, the field strength of the magnetic field being preferably in the range between 2 and 8 kilogauss. (U.S.)

  5. Nanostructuring by ion beam

    International Nuclear Information System (INIS)

    Valbusa, U.; Boragno, C.; Buatier de Mongeot, F.

    2003-01-01

    In metals, the surface curvature dependence of the sputtering yield and the presence of an extra energy barrier whenever diffusing adatoms try to descend step edges, produce a similar surface instability, which builds up regular patterns. By tuning the competition between these two mechanisms, it is possible to create self-organized structures of the size of few nanometers. Height, lateral distance and order of the structures change with the deposition parameters like ion energy, dose, incident angle and substrate temperature. The paper offers an overview of the experiments carried out and foresees possible applications of these results in the area of material science

  6. Ion implantation for semiconductors

    International Nuclear Information System (INIS)

    Grey-Morgan, T.

    1995-01-01

    Full text: Over the past two decades, thousands of particle accelerators have been used to implant foreign atoms like boron, phosphorus and arsenic into silicon crystal wafers to produce special embedded layers for manufacturing semiconductor devices. Depending on the device required, the atomic species, the depth of implant and doping levels are the main parameters for the implantation process; the selection and parameter control is totally automated. The depth of the implant, usually less than 1 micron, is determined by the ion energy, which can be varied between 2 and 600 keV. The ion beam is extracted from a Freeman or Bernas type ion source and accelerated to 60 keV before mass analysis. For higher beam energies postacceleration is applied up to 200 keV and even higher energies can be achieved by mass selecting multiplycharged ions, but with a corresponding reduction in beam output. Depending on the device to be manufactured, doping levels can range from 10 10 to 10 15 atoms/cm 2 and are controlled by implanter beam currents in the range up to 30mA; continuous process monitoring ensures uniformity across the wafer of better than 1 % . As semiconductor devices get smaller, additional sophistication is required in the design of the implanter. The silicon wafers charge electrically during implantation and this charge must be dissipated continuously to reduce the electrical stress in the device and avoid destructive electrical breakdown. Electron flood guns produce low energy electrons (below 10 electronvolts) to neutralize positive charge buildup and implanter design must ensure minimum contamination by other isotopic species and ensure low internal sputter rates. The pace of technology in the semiconductor industry is such that implanters are being built now for 256 Megabit circuits but which are only likely to be widely available five years from now. Several specialist companies manufacture implanter systems, each costing around US$5 million, depending on the

  7. Fontes de carboidratos e ionóforo em dietas contendo óleo vegetal para ovinos: digestibilidade, balanço de nitrogênio e fluxo portal de nutrientes Carbohydrate sources and ionophore in sheep diets with vegetal oil: digestibility, nitrogen balance and portal flux of nutrients

    Directory of Open Access Journals (Sweden)

    Gisele Fernanda Mouro

    2006-10-01

    Full Text Available Os objetivos neste trabalho foram avaliar a utilização de duas fontes de carboidratos (casca de soja e milho, com a utilização ou não de monensina em dietas com alta densidade lipídica, e seus efeitos sobre a digestibilidade dos nutrientes, o balanço de nitrogênio e o fluxo portal de nutrientes em ovinos. Adotou-se o método de coleta total de fezes e urina para determinação da digestibilidade e do balanço de nitrogênio. O fluxo líquido de nutrientes foi calculado pelo princípio de Fick. Foram utilizados quatro ovinos (54 kg de PV da raça Corriedale com três cateteres implantados (veia e artéria mesentérica e veia porta. A ingestão, a excreção fecal, a digestão e a digestibilidade de MS, MO e EE não foram influenciadas pelos tratamentos. A ingestão, a digestão e a digestibilidade da FDN foram maiores para as dietas com casca de soja (757,0; 531,1 g/dia e 70,2% que para aquelas com milho (392,3; 199,9 g/dia e 51,0%, enquanto a dos carboidratos não-fibrosos (CNF, foram maiores para as dietas com milho (474,6, 416,8 g/dia e 87,8% que para aquelas com casca de soja (148,0; 97,8 g/dia e 66,1%. A concentração de energia expressa como NDT foi maior nas dietas com milho (80,2% que naquelas com casca de soja (76,7%. Não houve efeito da utilização da monensina nos parâmetros de digestibilidade e balanço de nitrogênio. A excreção fecal da proteína foi menor e a digestibilidade maior para as dietas com milho. A concentração portal e arterial de nitrogênio alfa amino (N alfa-amino foi menor para as dietas com monensina (3,161 e 2,922 e 3,530 e 3,218 mM, respectivamente. A concentração portal (0,419 vs 0,516 mM, a diferença venosa-arterial (0,230 vs 0,317 mM e o fluxo portal de amônia (26,119 vs 37,041 mM/h foram menores para as dietas com milho.The objectives of this trial were to evaluate the effects of two carbohydrate sources (soybean hulls and corn grain with and without monensin on digestibility, nitrogen

  8. Heavy ion beams from the new Hungarian ECR ion source

    International Nuclear Information System (INIS)

    Biri, S.; Valek, A.; Ditroi, F.; Koivisto, H.; Arje, J.; Stiebing, K.; Schmidt, L.

    1998-01-01

    The first beams of highly charged ions in Hungary were obtained in fall of 1996. The new 14.5 GHz ECR ion source of ATOMKI produced beams of multiply charged ions with remarkable intensities at first experiments. Since then, numerous further developments were carried out. An external electrondonor electrode drastically increased the plasma density and, consequently, the intensity of highly charged ions. These upgrades concentrated mainly on beams from gaseous elements and were carried out by the ECRIS team of ATOMKI. Another series of experiments - ionising from solids - however, was done in the framework of an international collaboration. The first metal ion beam has been extracted from the ECRIS in November 1997 using the known method of Metal Ions from Volatile Compounds (MIVOC). The possibility to put the MIVOC chamber inside the ion source was also tested and the dosing regulation problem of metal vapours inside the ion source was solved. As a result, beams of more than 10 μA of highly charged Fe and Ni ions were produced. (author)

  9. Sympathetic cooling of ions in a hybrid atom ion trap

    Energy Technology Data Exchange (ETDEWEB)

    Hoeltkemeier, Bastian

    2016-10-27

    In this thesis the dynamics of a trapped ion immersed in a spatially localized buffer gas is investigated. For a homogeneous buffer gas, the ion's energy distribution reaches a stable equilibrium only if the mass of the buffer gas atoms is below a critical value. This limitation can be overcome by using multipole traps in combination and/or a spatially confined buffer gas. Using a generalized model for elastic collisions of the ion with the buffer gas atoms, the ion's energy distribution is numerically determined for arbitrary buffer gas distributions and trap parameters. Three regimes characterized by the respective analytic form of the ion's equilibrium energy distribution are found. One of these is a novel regime at large atom-to-ion mass ratios where the final ion temperature can tuned by adiabatically decreasing the spatial extension of the buffer gas and the effective ion trap depth (forced sympathetic cooling). The second part of the thesis presents a hybrid atom ion trap designed for sympathetic cooling of hydroxide anions. In this hybrid trap the anions are immersed in a cloud of laser cooled rubidium atoms. The translational and rovibrational temperatures of the anions is probed by photodetachment tomography and spectroscopy which shows the first ever indication of sympathetic cooling of anions by laser cooled atoms.

  10. Production of negative hydrogen ions from accelerated cluster ions

    International Nuclear Information System (INIS)

    Becker, E.W.; Falter, H.D.; Hagena, O.F.; Henkes, W.; Klingelhoefer, R.; Moser, H.O.; Obert, W.; Poth, I.

    1976-11-01

    Cluster ion acceleration is a method particularly well suited to produce neutral beams of high particle current density at energies of the order of 1 keV/atom. Since this is the energy required for converting hydrogen atoms or molecules into negative ions in a cesium vapour cell, it is proposed to use cluster ions for the production of negative ion beams of high current density. The system is envisaged as a tandem accelerator with a terminal voltage of 1 MV. (orig.) [de

  11. A novel planar ion funnel design for miniature ion optics

    International Nuclear Information System (INIS)

    Chaudhary, A.; Amerom, Friso H. W. van; Short, R. T.

    2014-01-01

    The novel planar ion funnel (PIF) design presented in this article emphasizes simple fabrication, assembly, and operation, making it amenable to extreme miniaturization. Simulations performed in SIMION 8.0 indicate that ion focusing can be achieved by using a gradient of electrostatic potentials on concentric metal rings in a plane. A prototype was fabricated on a 35 × 35 mm custom-designed printed circuit board (PCB) with a center hole for ions to pass through and a series of concentric circular metal rings of increasing diameter on the front side of the PCB. Metal vias on the PCB electrically connected each metal ring to a resistive potential divider that was soldered on the back of the PCB. The PIF was tested at 5.5 × 10 −6 Torr in a vacuum test setup that was equipped with a broad-beam ion source on the front and a micro channel plate (MCP) ion detector on the back of the PIF. The ion current recorded on the MCP anode during testing indicated a 23× increase in the ion transmission through the PIF when electric potentials were applied to the rings. These preliminary results demonstrate the functionality of a 2D ion funnel design with a much smaller footprint and simpler driving electronics than conventional 3D ion funnels. Future directions to improve the design and a possible micromachining approach to fabrication are discussed in the conclusions

  12. Note: Ion source design for ion trap systems

    Science.gov (United States)

    Noriega, J. R.; Quevedo, M.; Gnade, B.; Vasselli, J.

    2013-06-01

    A small plasma (glow discharge) based ion source and circuit are described in this work. The ion source works by producing a high voltage pulsed discharge between two electrodes in a pressure range of 50-100 mTorr. A third mesh electrode is used for ion extraction. The electrodes are small stainless steel screws mounted in a MACOR ionization chamber in a linear arrangement. The electrode arrangement is driven by a circuit, design for low power operation. This design is a proof of concept intended for applications on small cylindrical ion traps.

  13. Practical aspects of trapped ion mass spectrometry, 5 applications of ion trapping devices

    CERN Document Server

    March, Raymond E

    2009-01-01

    Examines ion/neutral and ion/ion reactions, ion spectroscopy, and the structural characterization of proteins and peptides using quadropole ion trap mass spectrometry, Fourier transform - ion cyclotron resonance (FT-ICR) mass spectrometry, and traveling wave ion mobility mass spectrometry.

  14. Contratados peninsulares para Cuba

    Directory of Open Access Journals (Sweden)

    Iglesias García, Fe

    1994-12-01

    Full Text Available Not available.

    Ante las presiones británicas, la metrópoli española y los ideólogos de los hacendados cubanos tuvieron que dar, desde la tercera década del siglo XIX, una respuesta a la previsible escasez de mano de obra esclava. El artículo estudia los sistemas de contrata implantados en la isla para abastecer de mano de obra blanca y barata a Cuba, deteniéndose particularmente la autora en el estudio de las condiciones de semiesclavitud que se escondían en las mencionadas contratas y en el perfil de los inmigrantes (profesiones, sexo, edad, procedencia....

  15. Sustantivos para definir homofobia

    OpenAIRE

    Campo Árias, Adalberto; Herazo, Edwin; Oviedo, Heidi

    2013-01-01

    Introducción. El término ‘homofobia’ es un concepto que se introdujo en el contexto académico hace más de 40 años. Sin embargo, la acepción ha tenido reparos y cambios en el tiempo. Objetivo. Revisar los sustantivos usados en los últimos doce años para definir homofobia. Metodología. Se realizó una búsqueda sistemática en Medline a través de Pubmed de publicaciones tipo editorial, cartas al editor, comentarios y entrevista en español o inglés. Se realizó un análisis cualitativo (teoría fundam...

  16. Bases para proyectiles dirigidos

    Directory of Open Access Journals (Sweden)

    Editorial, Equipo

    1959-03-01

    Full Text Available Aunque actualmente no se ha llegado a una línea general de métodos o sistemas que gobiernen un tipo característico de rampa y servicios auxiliares necesarios para el lanzamiento al espacio de proyectiles dirigidos a grandes alturas y distancias, las experiencias obtenidas en diferentes ensayos, utilizando distintos tipos de proyectiles y trayectorias balísticas, han sentado toda una serie de procedimientos, datos y conclusiones de gran valor balístico que, aun teniendo en cuenta la continua evolución del proyectil, sus formas, combustibles y alcances, se conocen ya, con bastante aproximación, las condiciones mínimas que ha de reunir una base dedicada a este tipo de lanzamientos.

  17. Registrar para avanzar

    Directory of Open Access Journals (Sweden)

    Laia Matarranz Torres

    2017-06-01

    Full Text Available El farmacéutico comunitario es un profesional sanitario con un enorme potencial para mejorar no solo el uso de los medicamentos (detectando, por ejemplo, resultados negativos de la medicación, sino también la prevención de enfermedades y la promoción de la salud pública. Sin duda, el desarrollo y el impulso que están teniendo los servicios profesionales farmacéuticos (SPF desde hace años pueden contribuir decisivamente a que este potencial se consolide de una forma definitiva, obteniendo el reconocimiento del conjunto del sistema sanitario, incluyendo tanto a otros profesionales de la salud (médicos, enfermería, medicina especializada… como a la Administración y, por supuesto, a los propios pacientes beneficiarios de estos servicios. Es cierto que la figura del farmacéutico y su ejercicio sanitario han estado tradicionalmente bien considerados por la población, pero no es menos verdad que la integración de la actividad asistencial de la farmacia comunitaria en el Sistema Nacional de Salud (SNS es, cuanto menos mejorable, y que, incluso, algunas manifestaciones ponen en entredicho de vez en cuando la labor científico-asistencial de las farmacias o generan dudas sobre su capacidad para formar parte de pleno derecho de los equipos de salud que deben trabajar de forma coordinado en la mejora de la atención sanitaria de los pacientes.

  18. Proton and carbon ion therapy

    CERN Document Server

    Lomax, Tony

    2013-01-01

    Proton and Carbon Ion Therapy is an up-to-date guide to using proton and carbon ion therapy in modern cancer treatment. The book covers the physics and radiobiology basics of proton and ion beams, dosimetry methods and radiation measurements, and treatment delivery systems. It gives practical guidance on patient setup, target localization, and treatment planning for clinical proton and carbon ion therapy. The text also offers detailed reports on the treatment of pediatric cancers, lymphomas, and various other cancers. After an overview, the book focuses on the fundamental aspects of proton and carbon ion therapy equipment, including accelerators, gantries, and delivery systems. It then discusses dosimetry, biology, imaging, and treatment planning basics and provides clinical guidelines on the use of proton and carbon ion therapy for the treatment of specific cancers. Suitable for anyone involved with medical physics and radiation therapy, this book offers a balanced and critical assessment of state-of-the-art...

  19. Air ions and aerosol science

    International Nuclear Information System (INIS)

    Tammet, H.

    1996-01-01

    Collaboration between Gas Discharge and Plasma Physics, Atmospheric Electricity, and Aerosol Science is a factor of success in the research of air ions. The concept of air ion as of any carrier of electrical current through the air is inherent to Atmospheric Electricity under which a considerable statistical information about the air ion mobility spectrum is collected. A new model of air ion size-mobility correlation has been developed proceeding from Aerosol Science and joining the methods of neighboring research fields. The predicted temperature variation of the mobility disagrees with the commonly used Langevin rule for the reduction of air ion mobilities to the standard conditions. Concurrent errors are too big to be neglected in applications. The critical diameter distinguishing cluster ions and charged aerosol particles has been estimated to be 1.4 endash 1.8 nm. copyright 1996 American Institute of Physics

  20. Ion climate and radon concentration

    International Nuclear Information System (INIS)

    Busbarna, L.

    1981-01-01

    Characteristic values of radon concentration in natural ion climate and in open air were compared and the effect of artificially produced negative ion excess on the radon concentration of air was studied. The results show that the radon concentration measurable at the rise of negative ion excess is smaller than that in the case of natural equilibrium. This effect can be utilized lowering the background of the scintillation chambers, thus increasing their sensitivity. The negative ions of the artificial ion climate lower radon concentration in closed space. The question arises whether only the ion climate is responsible for the effects on the organism and on the nervous system or the radon concentration of the air also contributes to them. (author)

  1. Ion implantation: an annotated bibliography

    International Nuclear Information System (INIS)

    Ting, R.N.; Subramanyam, K.

    1975-10-01

    Ion implantation is a technique for introducing controlled amounts of dopants into target substrates, and has been successfully used for the manufacture of silicon semiconductor devices. Ion implantation is superior to other methods of doping such as thermal diffusion and epitaxy, in view of its advantages such as high degree of control, flexibility, and amenability to automation. This annotated bibliography of 416 references consists of journal articles, books, and conference papers in English and foreign languages published during 1973-74, on all aspects of ion implantation including range distribution and concentration profile, channeling, radiation damage and annealing, compound semiconductors, structural and electrical characterization, applications, equipment and ion sources. Earlier bibliographies on ion implantation, and national and international conferences in which papers on ion implantation were presented have also been listed separately

  2. Fundamental processes in ion plating

    International Nuclear Information System (INIS)

    Mattox, D.M.

    1980-01-01

    Ion plating is a generic term applied to film deposition processes in which the substrate surface and/or the depositing film is subjected to a flux of high energy particles sufficient to cause changes in the interfacial region of film properties compared to a nonbombarded deposition. Ion plating is being accepted as an alternative coating technique to sputter deposition, vacuum evaporation and electroplating. In order to intelligently choose between the various deposition techniques, the fundamental mechanisms, relating to ion plating, must be understood. This paper reviews the effects of low energy ion bombardment on surfaces, interface formation and film development as they apply to ion plating and the implementation and applications of the ion plating process

  3. Rectangular ion funnel: a new ion funnel interface for structures for lossless ion manipulations.

    Science.gov (United States)

    Chen, Tsung-Chi; Webb, Ian K; Prost, Spencer A; Harrer, Marques B; Norheim, Randolph V; Tang, Keqi; Ibrahim, Yehia M; Smith, Richard D

    2015-01-06

    Structures for lossless ion manipulations (SLIM) have recently demonstrated the ability for near lossless ion focusing, transfer, and trapping in subatmospheric pressure regions. While lossless ion manipulations are advantageously applied to the applications of ion mobility separations and gas phase reactions, ion introduction through ring electrode ion funnels or more conventional ion optics to SLIM can involve discontinuities in electric fields or other perturbations that result in ion losses. In this work, we developed and investigated a new funnel design that aims to seamlessly couple to SLIM at the funnel exit. This rectangular ion funnel (RIF) was initially evaluated by ion simulations, fabricated utilizing printed circuit board technology, and tested experimentally. The RIF was integrated to a SLIM-time of flight (TOF) MS system, and the operating parameters, including RF, DC bias of the RIF electrodes, and electric fields for effectively interfacing with a SLIM, were characterized. The RIF provided a 2-fold sensitivity increase without significant discrimination over a wide m/z range and well matched to that of SLIM, along with greatly improved SLIM operational stability.

  4. Tandem Terminal Ion Source

    International Nuclear Information System (INIS)

    None

    2000-01-01

    OAK-B135 Tandem Terminal Ion Source. The terminal ion source (TIS) was used in several experiments during this reporting period, all for the(sup 7)Be((gamma))(sup 8)B experiment. Most of the runs used(sup 1)H(sup+) at terminal voltages from 0.3 MV to 1.5 MV. One of the runs used(sup 2)H(sup+) at terminal voltage of 1.4 MV. The other run used(sup 4)He(sup+) at a terminal voltage of 1.37 MV. The list of experiments run with the TIS to date is given in table 1 below. The tank was opened four times for unscheduled source repairs. On one occasion the tank was opened to replace the einzel lens power supply which had failed. The 10 kV unit was replaced with a 15 kV unit. The second time the tank was opened to repair the extractor supply which was damaged by a tank spark. On the next occasion the tank was opened to replace a source canal which had sputtered away. Finally, the tank was opened to replace the discharge bottle which had been coated with aluminum sputtered from the exit canal

  5. SUERC AMS ion detection

    Science.gov (United States)

    Maden, C.; Anastasi, P. A. F.; Dougans, A.; Freeman, S. P. H. T.; Kitchen, R.; Klody, G.; Schnabel, C.; Sundquist, M.; Vanner, K.; Xu, S.

    2007-06-01

    In a short time Be, C, Al, Cl, Ca and I accelerator mass spectrometry (AMS) have been established on the National Electrostatics Corporation (NEC) 5 MV pelletron system at the Scottish Universities Environmental Research Centre (SUERC). While summarising the present performance of the system, this report will focus on the details of ion detection, which sample materials are used and the analytical procedures employed for each individual species during routine analysis. All rare isotope detection is with a single flexible detector and ion event analysis system, but switching of analysed species typically requires a detector reconfiguration. Configurations for routine 10Be, 14C, 26Al, 36Cl, 41Ca and 129I detection have been established and will be presented here. Notably, there has proven to be sufficient suppression of the isobaric interferences of 36Cl and 41Ca in the 5+ charge state using an argon gas stripper at a terminal voltage of 5.0 MV to allow for routine analysis of these isotopes.

  6. Binding energy of protonium ions

    Science.gov (United States)

    Assad Abdel-Raouf, Mohamed

    2009-11-01

    The goal of the present work is to calculate the binding energy of the protonium ions bar PPe+ and bar PPe- using Rayleigh- Ritz variational method. It is indicated that an employment of 21 components of the trial wavefunction yields -0.08793 eV as the ground state energy of these ions. Our result agrees quite well with recently obtained results based on elaborate Monte Carlo approximations. It confirms the possible formation of these ions in laboratory.

  7. Highly Stripped Ion Sources for MeV Ion Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Hershcovitch, Ady

    2009-06-30

    Original technical objectives of CRADA number PVI C-03-09 between BNL and Poole Ventura, Inc. (PVI) were to develop an intense, high charge state, ion source for MeV ion implanters. Present day high-energy ion implanters utilize low charge state (usually single charge) ion sources in combination with rf accelerators. Usually, a MV LINAC is used for acceleration of a few rnA. It is desirable to have instead an intense, high charge state ion source on a relatively low energy platform (de acceleration) to generate high-energy ion beams for implantation. This de acceleration of ions will be far more efficient (in energy utilization). The resultant implanter will be smaller in size. It will generate higher quality ion beams (with lower emittance) for fabrication of superior semiconductor products. In addition to energy and cost savings, the implanter will operate at a lower level of health risks associated with ion implantation. An additional aim of the project was to producing a product that can lead to long­ term job creation in Russia and/or in the US. R&D was conducted in two Russian Centers (one in Tomsk and Seversk, the other in Moscow) under the guidance ofPVI personnel and the BNL PI. Multiple approaches were pursued, developed, and tested at various locations with the best candidate for commercialization delivered and tested at on an implanter at the PVI client Axcelis. Technical developments were exciting: record output currents of high charge state phosphorus and antimony were achieved; a Calutron-Bemas ion source with a 70% output of boron ion current (compared to 25% in present state-of-the-art). Record steady state output currents of higher charge state phosphorous and antimony and P ions: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb {sup 4 +}, Sb{sup 5+}, and Sb{sup 6+} respectively. Ultimate commercialization goals did not succeed (even though a number of the products like high

  8. Nuclear spin effect on recombination of H₃⁺ ions with electrons at 77 K.

    Science.gov (United States)

    Varju, J; Hejduk, M; Dohnal, P; Jílek, M; Kotrík, T; Plašil, R; Gerlich, D; Glosík, J

    2011-05-20

    Utilizing different ratios of para to ortho H₂ in normal and para enriched hydrogen, we varied the population of para-H₃⁺ in an H₃⁺ dominated plasma at 77 K. Absorption spectroscopy was used to measure the densities of the two lowest rotational states of H₃⁺. Monitoring plasma decays at different populations of para-H₃⁺ allowed us to determine the rate coefficients for binary recombination of para-H₃⁺ and ortho-H₃⁺ ions: (p)α(bin)(77 K) = (1.9 ± 0.4) × 10⁻⁷ cm³ s⁻¹ and (o)α(bin)(77 K) = (0.2 ± 0.2) × 10⁻⁷ cm³ s⁻¹.

  9. Negative ions of polyatomic molecules

    International Nuclear Information System (INIS)

    Christophorou, LG.

    1980-01-01

    In this paper general concepts relating to, and recent advances in, the study of negative ions of polyatomic molecules are discussed with emphasis on halocarbons. The topics dealt with in the paper are as follows: basic electron attachment processes, modes of electron capture by molecules, short-lived transient negative ions, dissociative electron attachment to ground-state molecules and to hot molecules (effects of temperature on electron attachment), parent negative ions, effect of density, nature, and state of the medium on electron attachment, electron attachment to electronically excited molecules, the binding of attached electrons to molecules (electron affinity), and the basic and the applied significance of negative-ion studies

  10. Ion injector for electrostatic accelerator

    International Nuclear Information System (INIS)

    Novikov, M.T.; Tsygikalo, A.A.

    1980-01-01

    Basing on the analysis of formulae connecting beam parameters at the input and output of an electrostatic accelerator, a design of an ion injector for a charge-exchange accelerator is suggested. The distinguishing injector feature is that it contains a preaccelerator with autofocusing of the beam at its output, which provides better matching of ion source and accelerator operating conditions when preserving the conditions of beam autofocusing in the accelerator. Such an injector is a self-contained instrument. It allows control, within certain limits, of ion optics of inlet lenses of the accelerator and preaccelerator during operation when preserving better matching of ion source operation with the accelerator [ru

  11. Ion beam assisted film growth

    CERN Document Server

    Itoh, T

    2012-01-01

    This volume provides up to date information on the experimental, theoretical and technological aspects of film growth assisted by ion beams.Ion beam assisted film growth is one of the most effective techniques in aiding the growth of high-quality thin solid films in a controlled way. Moreover, ion beams play a dominant role in the reduction of the growth temperature of thin films of high melting point materials. In this way, ion beams make a considerable and complex contribution to film growth. The volume will be essential reading for scientists, engineers and students working in thi

  12. The para-petroleum industry

    International Nuclear Information System (INIS)

    2002-07-01

    The para-petroleum industry includes societies that realize studies and installations for the deposits exploitation. This document presents the situation of the para-petroleum industry in 2001, the world investment growth of the activity, the french societies financial results and an inventory of the main operations in the amalgamation domain. (A.L.B.)

  13. Ion-Bombardment of X-Ray Multilayer Coatings - Comparison of Ion Etching and Ion Assisted Deposition

    NARCIS (Netherlands)

    Puik, E. J.; van der Wiel, M. J.; Zeijlemaker, H.; Verhoeven, J.

    1991-01-01

    The effects of two forms of ion bombardment treatment on the reflectivity of multilayer X-ray coatings were compared: ion etching of the metal layers, taking place after deposition, and ion bombardment during deposition, the so-called ion assisted deposition. The ion beam was an Ar+ beam of 200 eV,

  14. Salt stress induced ion accumulation, ion homeostasis, membrane ...

    African Journals Online (AJOL)

    Salt stress induced ion accumulation, ion homeostasis, membrane injury and sugar contents in salt-sensitive rice ( Oryza sativa L. spp. indica ) roots under isoosmotic conditions. ... The accumulation of sugars in PT1 roots may be a primary salt-defense mechanism and may function as an osmotic control. Key words: ...

  15. Adsorption of Acetic Acid, Cadmium ions, Lead ions and Iodine ...

    African Journals Online (AJOL)

    Michael Horsfall

    Adsorption of Acetic Acid, Cadmium ions, Lead ions and Iodine Using Activated. Carbon from Waste Wood and Rice Husks. GOODHEAD, T O; DAGDE, K K. Department of Chemical/Petrochemical Engineering, Rivers State university of Science and Technology. Port Harcourt, Nigeria. ABSTRACT: This paper presents the ...

  16. Ion implantation in Thailand (I) - development of ion implantation facilities

    International Nuclear Information System (INIS)

    Vilaithong, T.; Suwannakachorn, D.; Yotsombat, B.; Boonyawan, D.; Charoennugul, R.; Vichaisirimongkol, P.; Aumkaew, S.; A-No, V.

    1997-01-01

    Ion implantation with its many advantages has been widely and rapidly developed in the world to be a novel material treatment technique, which holds significance in both academic research and technical application. In order to develop and apply the ion implantation technique in the country, Thailand has launched a program to establish an ion beam center at Chiang Mai University. By efforts made during the past six years, the University has completed construction and installation of a 150-kV, research-purpose ion implantation facility, which consists of two beam lines - a 00 non-analyzed line and a 450 analyzed line, and which is being put into regular operation, and a 20-kV, high-current ion implanter based on a duoplasmatron ion source for non-analyzed N-ion beam implantation, and a high-intensity, multi cusp ion source for special implantation purposes. The facilities have formed powerful tools for research, teaching and engineering application, and have played an indispensable role in promoting development of novel techniques in the country

  17. Energy landscapes for mobile ions in ion conducting solids

    Indian Academy of Sciences (India)

    demonstrated here for a range of metaphosphate and diborate glasses, the complete description of the energy landscape for mobile ions also provides an effective tool for achieving a more detailed understanding of ion transport in glasses. The investigation of time evolutions can be included, if the bond valence analysis is ...

  18. ECR ion source based low energy ion beam facility

    Indian Academy of Sciences (India)

    Abstract. Mass analyzed highly charged ion beams of energy ranging from a few keV to a few. MeV plays an important role in various aspects of research in modern physics. In this paper a unique low energy ion beam facility (LEIBF) set up at Nuclear Science Centre (NSC) for providing low and medium energy multiply ...

  19. Ion trajectories in atom probe field ion microscopy and gas field ion sources

    CERN Document Server

    Castilho, C M C

    1999-01-01

    Trajectories of positive ions produced in a region close to a structured surface, modelled by spherical or spheroidal protrusions and kept at a positive electric potential with respect to a distant screen or detector are calculated. The results are discussed in comparison with similar practical situations produced by field ionization and field evaporation or desorption, such as those occurring in gas field ion sources, field ion microscopy and field desorption spectroscopy. (author)

  20. Upgraded vacuum arc ion source for metal ion implantation

    International Nuclear Information System (INIS)

    Nikolaev, A. G.; Oks, E. M.; Savkin, K. P.; Yushkov, G. Yu.; Brown, I. G.

    2012-01-01

    Vacuum arc ion sources have been made and used by a large number of research groups around the world over the past twenty years. The first generation of vacuum arc ion sources (dubbed ''Mevva,'' for metal vapor vacuum arc) was developed at Lawrence Berkeley National Laboratory in the 1980s. This paper considers the design, performance parameters, and some applications of a new modified version of this kind of source which we have called Mevva-V.Ru. The source produces broad beams of metal ions at an extraction voltage of up to 60 kV and a time-averaged ion beam current in the milliampere range. Here, we describe the Mevva-V.Ru vacuum arc ion source that we have developed at Tomsk and summarize its beam characteristics along with some of the applications to which we have put it. We also describe the source performance using compound cathodes.

  1. Ion energy distributions and sidewall profiles in reactive ion etching

    International Nuclear Information System (INIS)

    May, P.W.; Field, D.; Klemperer, D.F.; Song, Y.P.

    1993-01-01

    We present a brief resume of modelling of ion trajectories in radio frequency discharges of interest in reactive ion etching of semiconductors. The procedures for calculating the energies and angles at which ions strike the substrate surface are described. Examples of ion energy distributions (IEDs) and angular distributions (IADs) are given both for low pressure, collisionless-sheath plasmas, and for higher pressure conditions, where collisions significantly modify ion trajectories. Fast neutral particles formed in the sheath by collision processes are also considered. Computer modelling of the evolution of sidewall profiles during etch processes is discussed, and examples are given of profiles calculated using IED and IAD data both at low and high pressures. (orig.)

  2. Negative ion adsorption by the ion source surface as a factor influencing ion lifetime measurements

    Science.gov (United States)

    Lukin, V. G.; Khvostenko, O. G.

    2017-12-01

    It is well known that negative ions formed in the gas phase through low-energy electron capture by molecules show a scatter in the measured lifetimes of their autodetachment states. In considering this question, it was found that, when using a static sector magnetic mass spectrometer, some of the ions formed on the ionization chamber walls are adsorbed and stabilized there, then joining the registered ion flux and thereby distorting their measured lifetime. Because the number of the adsorbed ions depends on the experimental conditions, their contribution to the total flux is to some extent uncontrollable—hence, the scatter.

  3. Heavy ion beam probing

    Energy Technology Data Exchange (ETDEWEB)

    Hickok, R L

    1980-07-01

    This report consists of the notes distributed to the participants at the IEEE Mini-Course on Modern Plasma Diagnostics that was held in Madison, Wisconsin in May 1980. It presents an overview of Heavy Ion Beam Probing that briefly describes the principles and discuss the types of measurements that can be made. The problems associated with implementing beam probes are noted, possible variations are described, estimated costs of present day systems, and the scaling requirements for large plasma devices are presented. The final chapter illustrates typical results that have been obtained on a variety of plasma devices. No detailed calculations are included in the report, but a list of references that will provide more detailed information is included.

  4. Fast ion atomic spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Berry, H.G.; Young, L.; Goodman, L.S.; Somerville, L.P.; Hardis, J.; Neek, D.

    1984-01-01

    We have set up two collinear fast beam/laser excitation systems, one at the Argonne Dynamitron Accelerator (0.5 to 5.0 MeV beam energy) and another at a small electrostatic accelerator (20 to 130 keV). Our objective is to study fine structure, hyperfine structure and QED effects in ions of a few electrons. Initial projects underway include studies of multi-excited transitions in Li/sup -/ and Li/sup 0/, and transitions to high Rydberg states in H/sup 0/ and He/sup 0/. We have simultaneously excited a sodium jet with a laser at the resonance wavelength (D/sub 1/ or D/sub 2/ lines) and a 1-MeV He/sup +/ beam to produce excitation to autoionizing Na and Na/sup +/ states. The Auger electron spectra are compared to spectra obtained without laser excitation, and indicate strong variations in final state populations. 17 references.

  5. Miniature Lightweight Ion Pump

    Science.gov (United States)

    Sinha, Mahadeva P.

    2010-01-01

    This design offers a larger surface area for pumping of active gases and reduces the mass of the pump by eliminating the additional vacuum enclosure. There are three main components to this ion pump: the cathode and anode pumping elements assembly, the vacuum enclosure (made completely of titanium and used as the cathode and maintained at ground potential) containing the assembly, and the external magnet. These components are generally put in a noble diode (or differential) configuration of the ion pump technology. In the present state of the art, there are two cathodes, one made of titanium and the other of tantalum. The anodes are made up of an array of stainless steel cylinders positioned between the two cathodes. All the elements of the pump are in a vacuum enclosure. After the reduction of pressure in this enclosure to a few microns, a voltage is applied between the cathode and the anode elements. Electrons generated by the ionization are accelerated toward the anodes that are confined in the anode space by the axial magnetic field. For the generation of the axial field along the anode elements, the magnet is designed in a C-configuration and is fabricated from rare earth magnetic materials (Nd-B-Fe or Sm-Co) possessing high energy product values, and the yoke is fabricated from the high permeability material (Hiperco-50A composed of Fe-Co-V). The electrons in this region collide with the gas molecules and generate their positive ions. These ions are accelerated into the cathode and eject cathode material (Ti). The neutral atoms deposit on the anode surfaces. Because of the chemical activity of Ti, the atoms combine with chemically active gas molecules (e.g. N2, O2, etc.) and remove them. New layers of Ti are continually deposited, and the pumping of active gases is thus accomplished. Pumping of the inert gases is accomplished by their burial several atomic layers deep into the cathode. However, they tend to re-emit if the entrapping lattice atoms are

  6. Heavy ion beam probing

    International Nuclear Information System (INIS)

    Hickok, R.L.

    1980-07-01

    This report consists of the notes distributed to the participants at the IEEE Mini-Course on Modern Plasma Diagnostics that was held in Madison, Wisconsin in May 1980. It presents an overview of Heavy Ion Beam Probing that briefly describes the principles and discuss the types of measurements that can be made. The problems associated with implementing beam probes are noted, possible variations are described, estimated costs of present day systems, and the scaling requirements for large plasma devices are presented. The final chapter illustrates typical results that have been obtained on a variety of plasma devices. No detailed calculations are included in the report, but a list of references that will provide more detailed information is included

  7. Review of ion accelerators

    International Nuclear Information System (INIS)

    Alonso, J.

    1990-06-01

    The field of ion acceleration to higher energies has grown rapidly in the last years. Many new facilities as well as substantial upgrades of existing facilities have extended the mass and energy range of available beams. Perhaps more significant for the long-term development of the field has been the expansion in the applications of these beams, and the building of facilities dedicated to areas outside of nuclear physics. This review will cover many of these new developments. Emphasis will be placed on accelerators with final energies above 50 MeV/amu. Facilities such as superconducting cyclotrons and storage rings are adequately covered in other review papers, and so will not be covered here

  8. Focused ion beam technology

    International Nuclear Information System (INIS)

    Gamo, K.

    1993-01-01

    Focussed ion beam (FIB) technology has the advantage of being a maskless process compatible with UHV processing. This makes it attractive for use in in situ processing and has been applied to the fabrication of various mesoscopic structures. The present paper reviews these results whilst putting emphasis on in situ processing by a combined FIB and molecular beam epitaxy system. The typical performance of present FIB systems is also presented. In order to utilize the potential advantages of FIB processing, reduction of damage and improvement of throughput are important, and much effort has been devoted to developing processing techniques which require a reduced dose. The importance of low-energy FIB is discussed. (author)

  9. LEXUS heavy ion collisions

    CERN Document Server

    Sang Yong Jeon

    1997-01-01

    We use a Glauber-like approach to describe very energetic nucleus- nucleus collisions as a sequence of binary nucleon-nucleon collisions. No free parameters are needed: all the information comes from simple parametrizations of nucleon-nucleon collision data. Produced mesons are assumed not to interact with each other or with the original baryons. Comparisons are made to published experimental measurements of baryon rapidity and transverse momentum distributions, negative hadron rapidity and transverse momentum distributions, average multiplicities of pions, kaons, hyperons, and antihyperons, and zero degree energy distributions for sulfur-sulfur collisions at 200 GeV/c per nucleon and for lead-lead collisions at 158 GeV/c per nucleon. Good agreement is found except that the number of strange particles produced, especially antihyperons, is too small compared with experiment. We call this model LEXUS: Linear EXtrapolation of Ultrarelativistic nucleon-nucleon Scattering to heavy ion collisions. (11 refs).

  10. Relativistic heavy ion physics

    International Nuclear Information System (INIS)

    Hill, J.C.; Wohn, F.K.

    1993-01-01

    This is a progress report for the period May 1992 through April 1993. The first section, entitled ''Purpose and Trends, gives background on the recent trends in the research program and its evolution from an emphasis on nuclear structure physics to its present emphasis on relativistic heavy ion and RHIC physics. The next section, entitled ''Physics Research Progress'', is divided into four parts: participation in the program to develop a large detector named PHENIX for the RHIC accelerator; joining E864 at the AGS accelerator and the role in that experiment; progress made in the study of electromagnetic dissociation highlight of this endeavor is an experiment carried out with the 197 Au beam from the AGS accelerator in April 1992; progress in completion of the nuclear structure studies. In the final section a list of publications, invited talks, and contributed talks is given

  11. Photo ion spectrometer

    Science.gov (United States)

    Gruen, Dieter M.; Young, Charles E.; Pellin, Michael J.

    1989-01-01

    A charged particle spectrometer for performing ultrasensitive quantitative analysis of selected atomic components removed from a sample. Significant improvements in performing energy and angular refocusing spectroscopy are accomplished by means of a two dimensional structure for generating predetermined electromagnetic field boundary conditions. Both resonance and non-resonance ionization of selected neutral atomic components allow accumulation of increased chemical information. A multiplexed operation between a SIMS mode and a neutral atomic component ionization mode with EARTOF analysis enables comparison of chemical information from secondary ions and neutral atomic components removed from the sample. An electronic system is described for switching high level signals, such as SIMS signals, directly to a transient recorder and through a charge amplifier to the transient recorder for a low level signal pulse counting mode, such as for a neutral atomic component ionization mode.

  12. Review of ion accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, J.

    1990-06-01

    The field of ion acceleration to higher energies has grown rapidly in the last years. Many new facilities as well as substantial upgrades of existing facilities have extended the mass and energy range of available beams. Perhaps more significant for the long-term development of the field has been the expansion in the applications of these beams, and the building of facilities dedicated to areas outside of nuclear physics. This review will cover many of these new developments. Emphasis will be placed on accelerators with final energies above 50 MeV/amu. Facilities such as superconducting cyclotrons and storage rings are adequately covered in other review papers, and so will not be covered here.

  13. para promover la salud

    Directory of Open Access Journals (Sweden)

    Ma. del Consuelo Chapela

    2002-01-01

    Full Text Available Hablar de educación a distancia sustentada en el desarrollo de la cibernética obliga a reflexionar sobre sus definiciones, objetivos y medios, especialmente si pensamos en las necesidades de la fracción de población que no tiene acceso a las posibilidades que ofrece el desarrollo tecnológico. En este trabajo se presenta e ilustra con un ejemplo práctico, una perspectiva sobre las posibilidades de la educación a distancia desde las necesidades de la promoción de la salud entre grupos de población marginada en el mundo virtual. Se propone la creación de bibliotecas itinerantes regionales que pongan a disposición de la población con acceso limitado a la información, la tecnología comunicativa necesaria para apoyar los trabajos de promoción de la salud.

  14. Heavy ion driver technology

    International Nuclear Information System (INIS)

    Keefe, D.

    1988-09-01

    Major differences between fusion drivers and traditional accelerators include the following. The final beam current needed (/approximately/20 kA in a short pulse) is very much larger for a driver; such beams are dominated by repulsive space-charge effects since, even at 10 GeV, the ions are non-relativistic (v/c = 0.3). Also, the optical quality of the beams (called emittance by accelerator people) must be extremely good to ensure a suitably small focal spot at the pellet. Two schemes, one with a rf linac and storage rings, the other with a single-pass current-amplifying induction linac, are under study, the latter exclusively in the US. The induction linac approach lends itself to an examination in a sequence of scaled-down laboratory experiments since the most difficulties are expected to occur at the low energy end. Experiments and simulation have centered on a study of the transverse and longitudinal control of space-charge-dominated beams which are best described in terms of a non-neutral plasma rather than the traditional single-particle dynamics picture. An understanding of the high-current instability limits is required for arriving at a safe driver design. The final on-target beam current is so high that it must be carried in 16 separate focusing channels leading into the combustion chamber. While the energy deposition of the ions is expected to be entirely classical, there is a wealth of plasma physics phenomena to be explored (by theory and simulation) in the final propagation of these beams through the low-density gas in the chamber and in the environment of the hot target; it is important that none of these could result in a significant portion of the beam missing the focal spot. 13 refs., 9 figs., 1 tab

  15. Para-bosons and Para-fermions in Quantum Mechanics

    International Nuclear Information System (INIS)

    Cattani, M.S.D.; Fernandes, N.C.

    1982-01-01

    Within the framework of the ordinary quantum mechanics, a detailed study of the energy eigenfunctions of N identical particles using the irreducible representations of the permutation group in the Hilbert space is performed. It is shown that the para-states, as occurs with the boson and fermion states, are compatible with the postulates of quantum mechanics and with the principle of indistinguishability. A mathematical support for the existence of para-bosons and para-fermions is given. Gentile's quantum statistics is, in a certain sense, justified. (Author) [pt

  16. Formation of Ion Phase-Space Vortexes

    DEFF Research Database (Denmark)

    Pécseli, Hans; Trulsen, J.; Armstrong, R. J.

    1984-01-01

    The formation of ion phase space vortexes in the ion two stream region behind electrostatic ion acoustic shocks are observed in a laboratory experiment. A detailed analysis demonstrates that the evolution of such vortexes is associated with ion-ion beam instabilities and a nonlinear equation for ...

  17. Ion beams in materials processing and analysis

    CERN Document Server

    Schmidt, Bernd

    2012-01-01

    This book covers ion beam application in modern materials research, offering the basics of ion beam physics and technology and a detailed account of the physics of ion-solid interactions for ion implantation, ion beam synthesis, sputtering and nano-patterning.

  18. Lithium ion storage between graphenes

    Directory of Open Access Journals (Sweden)

    Chan Yue

    2011-01-01

    Full Text Available Abstract In this article, we investigate the storage of lithium ions between two parallel graphene sheets using the continuous approximation and the 6-12 Lennard-Jones potential. The continuous approximation assumes that the carbon atoms can be replaced by a uniform distribution across the surface of the graphene sheets so that the total interaction potential can be approximated by performing surface integrations. The number of ion layers determines the major storage characteristics of the battery, and our results show three distinct ionic configurations, namely single, double, and triple ion forming layers between graphenes. The number densities of lithium ions between the two graphenes are estimated from existing semi-empirical molecular orbital calculations, and the graphene sheets giving rise to the triple ion layers admit the largest storage capacity at all temperatures, followed by a marginal decrease of storage capacity for the case of double ion layers. These two configurations exceed the maximum theoretical storage capacity of graphite. Further, on taking into account the charge-discharge property, the double ion layers are the most preferable choice for enhanced lithium storage. Although the single ion layer provides the least charge storage, it turns out to be the most stable configuration at all temperatures. One application of the present study is for the design of future high energy density alkali batteries using graphene sheets as anodes for which an analytical formulation might greatly facilitate rapid computational results.

  19. Propagation of Ion Acoustic Perturbations

    DEFF Research Database (Denmark)

    Pécseli, Hans

    1975-01-01

    Equations describing the propagation of ion acoustic perturbations are considered, using the assumption that the electrons are Boltzman distributed and isothermal at all times. Quasi-neutrality is also considered.......Equations describing the propagation of ion acoustic perturbations are considered, using the assumption that the electrons are Boltzman distributed and isothermal at all times. Quasi-neutrality is also considered....

  20. Spacecraft ion beam noise effects

    Science.gov (United States)

    Anenberg, G. L.

    1972-01-01

    An estimate of the antenna noise temperature and the uplink signal-to-noise ratio has been made for Bremsstrahlung radiation emitted by a spacecraft ion beam; a worst-case situation in which the spacecraft antenna is located in the exit plane of the ion beam and directed at varying angles into the ion beam is assumed. Numerical results of the antenna noise temperature versus antenna pointing angle are given for a typical set of ion beam and antenna pattern parameters. The uplink signal-to-noise ratio due to the ion beam noise alone is given in terms of a critical range in AU at which a typical ranging transmission is received with S/N = 0 db. The effects of the ion beam divergence angle and antenna distance on the ion beam are also presented. Results of the study show typical increases in the antenna noise temperature of about 0.2 K and critical ranges of the order of 3-5 AU. An ion engine thus generally introduces an undetectable level of noise into a spacecraft receiver.

  1. SPS Ion Induced Desorption Experiment

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    This experiment will give a study about the induced desorption from heavy ion (Indium ion run from week 45 in SPS T4-H8 area) impacting LHC type graphite collimator. 4 different samples are located in the 4 chambers 90° one to each other: pure graphite, graphite with copper coating, graphite with NEG coating, 316LN stainless steal (reference).

  2. Bundle Security Protocol for ION

    Science.gov (United States)

    Burleigh, Scott C.; Birrane, Edward J.; Krupiarz, Christopher

    2011-01-01

    This software implements bundle authentication, conforming to the Delay-Tolerant Networking (DTN) Internet Draft on Bundle Security Protocol (BSP), for the Interplanetary Overlay Network (ION) implementation of DTN. This is the only implementation of BSP that is integrated with ION.

  3. High Resolution Scanning Ion Microscopy

    NARCIS (Netherlands)

    Castaldo, V.

    2011-01-01

    The structure of the thesis is the following. The first chapter is an introduction to scanning microscopy, where the path that led to the Focused Ion Beam (FIB) is described and the main differences between electrons and ion beams are highlighted. Chapter 2 is what is normally referred to (which I

  4. Hooded arc ion-source

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    The positioning system for the hooded arc ion-source, shown prior to mounting, consists of four excentric shafts to locate the ion-source and central electrodes. It will be placed on the axis of the SC and introduced into the vacuum tank via the air locks visible in the foreground.

  5. Heavy-ion superconducting linacs

    International Nuclear Information System (INIS)

    Delayen, J.R.

    1989-01-01

    This paper reviews the status of the superconducting heavy-ion accelerators. Most of them are linacs used as boosters for tandem electrostatic accelerators, although the technology is being extended to very low velocity to eliminate the need for an injector. The characteristics and features of the various superconducting heavy-ion accelerators are discussed. 45 refs

  6. Targets for heavy ion fusion

    International Nuclear Information System (INIS)

    Clauser, M.J.

    1978-01-01

    This paper describes some of the basic principles of fusion target implosions, using some simple targets designed for irradiation by ion beams. Present estimates are that ion beams with 1-5 MJ, and 100-500 TW will be required to ignite high gain targets. (orig.) [de

  7. in heavy-ion collisions

    Indian Academy of Sciences (India)

    2015-05-06

    May 6, 2015 ... the 'Big Bang', and has now been (re-)created as the hottest matter ever in laboratory by heavy-ion collisions ('Little Bang') at the Relativistic Heavy Ion Collider (RHIC) as well as at the Large Hadron Collider (LHC). To experimentally measure and theoretically understand the various properties of the QGP ...

  8. Project of an ion thruster

    International Nuclear Information System (INIS)

    Perche, G.E.

    1983-07-01

    The mercury bombardment electrostatic ion thruster is the most successful electric thruster available today. This work describes a 5 cm diameter ion thruster with 3.000 s specific impulse and 5 mN thrust. The advantages of electric propulsion and the tests that will be performed are also presented. (Author) [pt

  9. Quantum computing with trapped ions

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, R.J.

    1998-01-01

    The significance of quantum computation for cryptography is discussed. Following a brief survey of the requirements for quantum computational hardware, an overview of the ion trap quantum computation project at Los Alamos is presented. The physical limitations to quantum computation with trapped ions are analyzed and an assessment of the computational potential of the technology is made.

  10. Ion-Molecule Reaction Dynamics.

    Science.gov (United States)

    Meyer, Jennifer; Wester, Roland

    2017-05-05

    We review the recent advances in the investigation of the dynamics of ion-molecule reactions. During the past decade, the combination of single-collision experiments in crossed ion and neutral beams with the velocity map ion imaging detection technique has enabled a wealth of studies on ion-molecule reactions. These methods, in combination with chemical dynamics simulations, have uncovered new and unexpected reaction mechanisms, such as the roundabout mechanism and the subtle influence of the leaving group in anion-molecule nucleophilic substitution reactions. For this important class of reactions, as well as for many fundamental cation-molecule reactions, the information obtained with crossed-beam imaging is discussed. The first steps toward understanding micro-solvation of ion-molecule reaction dynamics are presented. We conclude with the presentation of several interesting directions for future research.

  11. RHIC heavy ion operations performance

    CERN Document Server

    Satogata, T; Ferrone, R; Pilat, F

    2006-01-01

    The Relativistic Heavy Ion Collider (RHIC) completed its fifth year of operation in 2005, colliding copper ion beams with ps=200 GeV/u and 62.4 GeV/u[1]. Previous heavy ion runs have collided gold ions at ps=130 GeV/u, 200 GeV/u, and 62.4 GeV/u[2], and deuterons and gold ions at ps=200 GeV/u[3]. This paper discusses operational performance statistics of this facility, including Cu- Cu delivered luminosity, availability, calendar time spent in physics stores, and time between physics stores. We summarize the major factors affecting operations efficiency, and characterize machine activities between physics stores.

  12. Ion bombardment modification of surfaces

    International Nuclear Information System (INIS)

    Auciello, O.

    1984-01-01

    An historical overview of the main advances in the understanding of bombardment-induced surface topography is presented. The implantation and sputtering mechanisms which are relevant to ion bombardment modification of surfaces and consequent structural, electronic and compositional changes are described. Descriptions of plasma and ion-beam sputtering-induced film formation, primary ion-beam deposition, dual beam techniques, cluster of molecule ion-beam deposition, and modification of thin film properties by ion bombardment during deposition are presented. A detailed account is given of the analytical and computational modelling of topography from the viewpoint of first erosion theory. Finally, an account of the possible application and/or importance of textured surfaces in technologies and/or experimental techniques not considered in previous chapters is presented. refs.; figs.; tabs

  13. Ion sources for electrostatic accelerators

    International Nuclear Information System (INIS)

    Hellborg, R.

    1998-01-01

    Maybe the most important part of an electrostatic accelerator system, and also often the most tricky part is the ion source. There has been a rapid growth in activity in ion-source research and development during the last two to three decades. Some of these developments have also been of benefit to electrostatic accelerator users. In this report some of the different types of ion sources used in electrostatic accelerators are described. The list is not complete but more an overview of some of the more commonly used sources. The description is divided into two groups; positive ion sources for single stage electrostatic accelerators and negative ion sources for two stages (i.e. tandem) accelerators

  14. Isochronous cyclotrons. Multicharged ion accelerators

    International Nuclear Information System (INIS)

    Shelaev, I.A.

    1976-01-01

    Isochronous cyclotrons for heavy ions are considered. A development of the heavy ion acceleration technique is discussed. The advantages of heavy ion acceleration by means of the isochronous cyclotron in the energy range up to 10 MeV/nucleon are shown. The requirements to an increase of the beam intensity and decrease of the accelerator dimensions are determined. A considerable increase in the beam intensity is achieved in cascade accelerators of heavy ions. Various schemes of such accelerators are considered, and their parameters are given. To obtain the nuclei with energy of 10 GeV/nucleon and higher, some accelerating complexes are projected, e.g. nuclotrons, where the superconducting magnets are supposed to be used. New methods for heavy ion acceleration are worked out, especially, the collective methods of acceleration

  15. The ATLAS positive ion injector

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, K.W.; Bollinger, L.M.; Pardo, R.C.

    1990-01-01

    This paper reviews the design, construction status, and beam tests to date of the positive ion injector (PII) which is replacing the tandem injector for the ATLAS heavy-ion facility. PII consists of an ECR ion source on a 350 KV platform injecting a very low velocity superconducting linac. The linac is composed of an independently-phased array of superconducting four-gap interdigital resonators which accelerate over a velocity range of .006 to .05c. In finished form, PII will be able to inject ions as heavy as uranium into the existing ATLAS linac. Although at the present time little more than 50% of the linac is operational, the indenpently-phased array is sufficiently flexible that ions in the lower half of the periodic table can be accelerated and injected into ATLAS. Results of recent operational experience will be discussed. 5 refs.

  16. The ATLAS positive ion injector

    International Nuclear Information System (INIS)

    Shepard, K.W.; Bollinger, L.M.; Pardo, R.C.

    1990-01-01

    This paper reviews the design, construction status, and beam tests to date of the positive ion injector (PII) which is replacing the tandem injector for the ATLAS heavy-ion facility. PII consists of an ECR ion source on a 350 KV platform injecting a very low velocity superconducting linac. The linac is composed of an independently-phased array of superconducting four-gap interdigital resonators which accelerate over a velocity range of .006 to .05c. In finished form, PII will be able to inject ions as heavy as uranium into the existing ATLAS linac. Although at the present time little more than 50% of the linac is operational, the indenpently-phased array is sufficiently flexible that ions in the lower half of the periodic table can be accelerated and injected into ATLAS. Results of recent operational experience will be discussed. 5 refs

  17. Binary and ternary recombination of para-H3(+) and ortho-H3(+) with electrons: state selective study at 77-200 K.

    Science.gov (United States)

    Dohnal, Petr; Hejduk, Michal; Varju, Jozef; Rubovič, Peter; Roučka, Štěpán; Kotrík, Tomáš; Plašil, Radek; Glosík, Juraj; Johnsen, Rainer

    2012-06-28

    Measurements in H(3)(+) afterglow plasmas with spectroscopically determined relative abundances of H(3)(+) ions in the para-nuclear and ortho-nuclear spin states provide clear evidence that at low temperatures (77-200 K) para-H(3)(+) ions recombine significantly faster with electrons than ions in the ortho state, in agreement with a recent theoretical prediction. The cavity ring-down absorption spectroscopy used here provides an in situ determination of the para/ortho abundance ratio and yields additional information on the translational and rotational temperatures of the recombining ions. The results show that H(3)(+) recombination with electrons occurs by both binary recombination and third-body (helium) assisted recombination, and that both the two-body and three-body rate coefficients depend on the nuclear spin states. Electron-stabilized (collisional-radiative) recombination appears to make only a small contribution.

  18. Binary and ternary recombination of para-H3+ and ortho-H3+ with electrons: State selective study at 77-200 K

    Science.gov (United States)

    Dohnal, Petr; Hejduk, Michal; Varju, Jozef; Rubovič, Peter; Roučka, Štěpán; Kotrík, Tomáš; Plašil, Radek; Glosík, Juraj; Johnsen, Rainer

    2012-06-01

    Measurements in H_3^+ afterglow plasmas with spectroscopically determined relative abundances of H_3^+ ions in the para-nuclear and ortho-nuclear spin states provide clear evidence that at low temperatures (77-200 K) para-H_3^+ ions recombine significantly faster with electrons than ions in the ortho state, in agreement with a recent theoretical prediction. The cavity ring-down absorption spectroscopy used here provides an in situ determination of the para/ortho abundance ratio and yields additional information on the translational and rotational temperatures of the recombining ions. The results show that H_3^+ recombination with electrons occurs by both binary recombination and third-body (helium) assisted recombination, and that both the two-body and three-body rate coefficients depend on the nuclear spin states. Electron-stabilized (collisional-radiative) recombination appears to make only a small contribution.

  19. Marcadores para la Realidad Aumentada para fines educativos

    Directory of Open Access Journals (Sweden)

    María Reina Zarate Nava

    2013-12-01

    Full Text Available La Realidad Aumentada (AR es considerada por algunos expertos como la tecnología en crecimiento para el 2014, en diferentes sectores: ingeniería, educación, juegos y negocios, siendo este último el más usado en él 2013. Sin embargo en el sector educativo la AR se presenta en algunos proyectos que se han desarrollado para diferentes áreas de las ciencias, como Química, Física y Matemáticas, lo anterior con el objetivo de facilitar el proceso de Enseñanza-Aprendizaje. En el presente artículo se presenta el modelo de patrones utilizado para un Proyecto AR enfocado en Química, el cual presenta un conjunto de patrones que fueron valorados para facilitar el rastreo de los objetos y a su vez el entendimiento de algunos materiales de los laboratorios de Química I.

  20. Response of thermal ions to electromagnetic ion cyclotron waves

    Science.gov (United States)

    Anderson, B. J.; Fuselier, S. A.

    1994-01-01

    Electromagnetic ion cyclotron waves generated by 10 - 50 keV protons in the Earth's equatorial magnetosphere will interact with the ambient low-energy ions also found in this region. We examine H(+) and He(+) distribution functions from approx. equals 1 to 160 eV using the Hot Plasma Composition Experiment instrument on AMPTE/CCE to investigate the thermal ion response to the waves. A total of 48 intervals were chosen on the basis of electromagnetic ion cyclotron (EMIC) wave activity: 24 with prevalent EMIC waves and 24 with no EMIC waves observed on the orbit. There is a close correlation between EMIC waves and perpendicular heated ion distributions. For protons the perpendicular temperature increase is modest, about 5 eV, and is always observed at 90 deg pitch angles. This is consistent with a nonresonant interaction near the equator. By contrast, He(+) temperatures during EMIC wave events averaged 35 eV and sometimes exceeded 100 eV, indicating stronger interaction with the waves. Furthermore, heated He(+) ions have X-type distributions with maximum fluxes occurring at pitch angles intermediate between field-aligned and perpendicular directions. The X-type He(+) distributions are consistent with a gyroresonant interaction off the equator. The concentration of He(+) relative to H(+) is found to correlate with EMIC wave activity, but it is suggested that the preferential heating of He(+) accounts for the apparent increase in relative He(+) concentration by increasing the proportion of He(+) detected by the ion instrument.

  1. Ions kinematics in an electrostatic ion beam trap

    Energy Technology Data Exchange (ETDEWEB)

    Attia, D

    2004-06-01

    In this study, I have tried to provide a better understanding of the dynamics of ions inside an electrostatic ion beam trap. The electrostatic ion trap allows to store ions moving between two electrostatic mirrors. Although the trap has been developed already seven years ago, no direct measurement of the transversal velocity distribution of the ions has been performed. Such quantity is central for understanding the conditions under which a beam should be produced (mainly emittance) in order to be trapped by such a device. The data I have obtained during the course of this work are based on an experimental technique which relies on the direct imaging of the particles exiting the trap, as well as on numerical simulations of the ion trajectories inside the trap. I have personally been involved in the hardware development of the imaging system, the data acquisition and analysis of the data as well as il all numerical calculations presented here. These results allow us to obtain, for the first time, experimental information on the transverse phase space of the trap, and contribute to the overall understanding of the ion motion in this system. (author)

  2. Una agenda para educadores

    Directory of Open Access Journals (Sweden)

    Robert O. McClintock

    2007-01-01

    Full Text Available Las instituciones educativas constituyen los principales factores en la construcción social de un nuevo sistema educativo. Las escuelas y los educadores controlan y producen propiedad intelectual de una extraordinaria profundidad y amplitud. Los cambios producidos por las tecnologías digitales están consiguiendo que el acceso y la producción de conocimiento sea más accesible y universal. Lo que es, a la vez, un gran logro de apertura curricular, pero también un grave peligro de perder la perspectiva eminentemente “educativa” de la transmisión del conocimiento en la escuela. Los nuevos recursos permiten a los educadores romper el ciclo de reproducción en los logros educativos, acercarse al medio y a la familia y transformar la escuela. Los educadores y las escuelas deben asumir el reto de constituir comunidades de aprendizaje. Así como de atreverse a producir y difundir ese conocimiento con soporte digital. Lo contrario sería una terrible abdicación. El artículo traza un recorrido histórico sobre esta función de la escuela y su adaptación a los medios y recursos de cada época. Tras lo cual, aboga por asumir el desafío actual de las TICs, para renovar el vínculo progresista con la posteridad y construir un mejor futuro. Los nuevos recursos permiten a los educadores romper el ciclo de reproducción en los logros educativos, acercarse al medio y a la familia y transformar la escuela.

  3. Compuestos de organosilicio para almacenamiento de energía Compuestos de organosilicio para almacenamiento de energía

    Directory of Open Access Journals (Sweden)

    Adrián Peña-Hueso

    2012-02-01

    Full Text Available   Las pilas recargables de ion litio han tenido un considerable desarrollo en los últimos años y son ampliamente utilizadas en dispositivos electrónicos. Los derivados de organosilicio enlazados a unidades de etilenglicol están siendo estudiados como una opción atractiva para sustituir a los disolventes convencionales en la preparación de electrolitos, pues poseen altos puntos de inflamación, buena conductividad, baja toxicidad y buena estabilidad electroquímica. Aunado a eso, la síntesis de estos compuestos a partir de materias primas sencillas y económicas los convierte en buenos candidatos para su uso en pilas de ion litio a nivel comercial. En este artículo se hace una revisión de los aspectos más sobresalientes del trabajo con electrolitos de organosilanos que ha realizado el Dr. Robert West.There has been a large development of Li-ion batteries during last years and they are widely used in consumer electronic devices. Organosilicon compounds coupled to ethylene glycol chains are being studied as a good option to substitute conventional solvents in the preparation of electrolytes, because they have high flash points, good conductivities, low toxicity and good electrochemical stability. These compounds are prepared from simple and cheap reagents, which also makes them attractive for their industrial application in Li-ion batteries. This paper is a review of the most important results obtained by Professor Robert West in the field of organosilicon electrolytes.

  4. Ion Rings for Magnetic Fusion

    Energy Technology Data Exchange (ETDEWEB)

    Greenly, John, B.

    2005-07-31

    This Final Technical Report presents the results of the program, Ion Rings for Magnetic Fusion, which was carried out under Department of Energy funding during the period August, 1993 to January, 2005. The central objective of the program was to study the properties of field-reversed configurations formed by ion rings. In order to reach this objective, our experimental program, called the Field-reversed Ion Ring Experiment, FIREX, undertook to develop an efficient, economical technology for the production of field-reversed ion rings. A field-reversed configuration (FRC) in which the azimuthal (field-reversing) current is carried by ions with gyro-radius comparable to the magnetic separatrix radius is called a field-reversed ion ring. A background plasma is required for charge neutralization of the ring, and this plasma will be confined within the ring's closed magnetic flux. Ion rings have long been of interest as the basis of compact magnetic fusion reactors, as the basis for a high-power accelerator for an inertial fusion driver, and for other applications of high power ion beams or plasmas of high energy density. Specifically, the FIREX program was intended to address the longstanding question of the contribution of large-orbit ions to the observed stability of experimental FRCs to the MHD tilt mode. Typical experimental FRCs with s {approx} 2-4, where s is the ratio of separatrix radius to ion gyro-radius, have been stable to tilting, but desired values for a fusion reactor, s > 20, should be unstable. The FIREX ring would consist of a plasma with large s for the background ions, but with s {approx} 1 for the ring ions. By varying the proportions of these two populations, the minimum proportion of large-orbit ions necessary for stability could be determined. The incorporation of large-orbit ions, perhaps by neutral-beam injection, into an FRC has been advanced for the purpose of stabilizing, heating, controlling angular momentum, and aiding the formation

  5. Three-dimensional simulations of ion dynamics in an Electron Cyclotron Resonance Ion Source

    NARCIS (Netherlands)

    Beijers, J. P. M.; Mironov, V.

    We present a three-dimensional simulation of the ion dynamics in an electron cyclotron resonance ion source. Ion trajectories in the min-B field of the source are calculated taking ion-ion and electron-ion collisions into account. The electrons are not tracked but considered as a neutralizing

  6. High Current Ion Sources and Injectors for Heavy Ion Fusion

    Energy Technology Data Exchange (ETDEWEB)

    Kwan, Joe W.

    2005-02-15

    Heavy ion beam driven inertial fusion requires short ion beam pulses with high current and high brightness. Depending on the beam current and the number of beams in the driver system, the injector can use a large diameter surface ionization source or merge an array of small beamlets from a plasma source. In this paper, we review the scaling laws that govern the injector design and the various ion source options including the contact ionizer, the aluminosilicate source, the multicusp plasma source, and the MEVVA source.

  7. Data acquisition for the HILI [Heavy Ion Light Ion] detector

    International Nuclear Information System (INIS)

    Teh, K.M.; Shapira, D.; McConnell, J.W.; Kim, H.; Novotny, R.

    1987-01-01

    A large acceptance, multi-segmented detector system capable of the simultaneous detection of heavy and light ions has been constructed. The heavy ions are detected with a segmented gas ionization chamber and a multiwire proportional counter while the light ions are detected with a 192 element plastic phoswich hodoscope. Processing the large number of signals is accomplished through a combination of CAMAC and FASTBUS modules and preprocessors, and a Host minicomputer. Details of the data acquisition system and the reasons for adopting a dual standards system are discussed. In addition, a technique for processing signals from an individual hodoscope detector is presented. 4 refs., 3 figs

  8. Ion ring compressor as a high-current ion accelerator

    International Nuclear Information System (INIS)

    Fleischmann, H.H.

    1977-01-01

    The acceleration of large amounts of protons to several hundred MeV by adiabatic magnetic compression of low-energy ion rings are discussed. This method is to be used in the Ion Ring Compressor approach to thermonuclear fusion. Results from present experimental and theoretical investigations and estimates indicate good overall chances for a technical and economic feasibility of such a system. The method of acceleration might be used to generate efficiently the rather large amounts of several hundred MeV hydrogen ions that will be needed in any economically significant electronuclear breeding scheme

  9. Ion beam analysis of metal ion implanted surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Evans, P.J.; Chu, J.W.; Johnson, E.P.; Noorman, J.T. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Sood, D.K. [Royal Melbourne Inst. of Tech., VIC (Australia)

    1993-12-31

    Ion implantation is an established method for altering the surface properties of many materials. While a variety of analytical techniques are available for the characterisation of implanted surfaces, those based on particle accelerators such as Rutherford backscattering (RBS) and nuclear reaction analysis (NRA) provide some of the most useful and powerful for this purpose. Application of the latter techniques to metal ion implantation research at ANSTO will be described with particular reference to specific examples from recent studies. Where possible, the information obtained from ion beam analysis will be compared with that derived from other techniques such as Energy Dispersive X-ray (EDX) and Auger spectroscopies. 4 refs., 5 figs.

  10. Development of a microwave ion source for ion implantations

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, N., E-mail: Nbk-Takahashi@shi.co.jp; Murata, H.; Kitami, H.; Mitsubori, H.; Sakuraba, J.; Soga, T.; Aoki, Y.; Katoh, T. [Technology Research Center, Sumitomo Heavy Industries Ltd., Yokosuka, Kanagawa 237-8555 (Japan)

    2016-02-15

    A microwave ion source is expected to have a long lifetime, as it has fewer consumables. Thus, we are in the process of developing a microwave ion source for ion implantation applications. In this paper, we report on a newly developed plasma chamber and the extracted P{sup +} beam currents. The volume of the plasma chamber is optimized by varying the length of a boron nitride block installed within the chamber. The extracted P{sup +} beam current is more than 30 mA, at a 25 kV acceleration voltage, using PH{sub 3} gas.

  11. The Ion Funnel: Theory, Implementations, and Applications

    Science.gov (United States)

    Kelly, Ryan T.; Tolmachev, Aleksey V.; Page, Jason S.; Tang, Keqi; Smith, Richard D.

    2009-01-01

    The electrodynamic ion funnel has enabled the manipulation and focusing of ions in a pressure regime (0.1 to 30 Torr) that has challenged traditional approaches, providing the basis for much greater mass spectrometer ion transmission efficiencies. The initial ion funnel implementations aimed to efficiently capture ions in the expanding gas jet of an electrospray ionization source and radially focus them for efficient transfer through a conductance limiting orifice. We review the improvements in fundamental understanding of ion motion in ion funnels, the evolution in its implementations that have brought the ion funnel to its current state of refinement, as well as applications of the ion funnel for purposes such as ion trapping, ion cooling, low pressure electrospray, and ion mobility spectrometry. PMID:19391099

  12. Triplemafios: a multicharged heavy ion source

    International Nuclear Information System (INIS)

    Briand, P.; Geller, R.; Jacquot, B.

    1976-01-01

    The principle and the characteristics of the ion source 'Triplemafios' are described. We also furnish the upto date performances concerning the ion charge states, ion currents and globale emittances of the beam [fr

  13. Ion-ion interaction and energy transfer of 4+ transuranium ions in cerium tetrafluoride

    Energy Technology Data Exchange (ETDEWEB)

    Liu, G.K.; Beitz, J.V.

    1990-01-01

    Dynamics of excited 5f electron states of the transuranium ions Cm{sup 4+} and Bk{sup 4+} in CeF{sub 4} are compared. Based on time- and wavelength-resolved laser-induced fluorescence, excitation energy transfer processes have been probed. Depending on concentration and electronic energy level structure of the studied 4+ transuranium ion, the dominant energy transfer mechanisms were identified as cross relaxation, exciton-exciton annihilation, and trapping. Energy transfer rates derived from the fitting of the observed fluorescence decays to theoretical models, based on electric multipolar ion-ion interactions, are contrasted with prior studies of 4f states of 3+ lanthanide and 3d states of transition metal ions. 16 refs., 1 tab.

  14. Unlimited ion acceleration by radiation pressure.

    Science.gov (United States)

    Bulanov, S V; Echkina, E Yu; Esirkepov, T Zh; Inovenkov, I N; Kando, M; Pegoraro, F; Korn, G

    2010-04-02

    The energy of ions accelerated by an intense electromagnetic wave in the radiation pressure dominated regime can be greatly enhanced due to a transverse expansion of a thin target. The expansion decreases the number of accelerated ions in the irradiated region resulting in an increase in the ion energy and in the ion longitudinal velocity. In the relativistic limit, the ions become phase locked with respect to the electromagnetic wave resulting in unlimited ion energy gain.

  15. Materials research with ion beams

    International Nuclear Information System (INIS)

    Meyer, J.D.

    1988-01-01

    This report gives a series of helpful programs which are used in materials research with ion beams. In this context algorithms which can substitute table books are dealt with. This is true for the programs DEDX and PRAL; they are used in order to determine the energy loss of ions in solid bodies, their working range and straggling. Furthermore, simulator routines and analyzers are described. The program TRIM simulates the physical phenomena which occur with the penetration of high-energy ions into solid bodies. In this context electronic excitations, phonons and lattice distortions which are caused by the ions are dealt with. For the experimental ion implantation it is interesting to know the final distribution of the simulated ions in the solid body. The program RBS simulates the Rutherford spectrum of ions which are scattered from a solid body which may consist of up to nine elements and up to one hundred layers. The unknown composition of a solid body can be determined in direct comparison with the experimental spectrum. The program NRA determines concentration and penetrative distribution of an impurity by means of the experimental nuclear reaction spectrum of this impurity. All programs are written in FORTRAN 77. (orig./MM) [de

  16. Multi-source ion funnel

    Science.gov (United States)

    Tang, Keqi; Belov, Mikhail B.; Tolmachev, Aleksey V.; Udseth, Harold R.; Smith, Richard D.

    2005-12-27

    A method for introducing ions generated in a region of relatively high pressure into a region of relatively low pressure by providing at least two electrospray ion sources, providing at least two capillary inlets configured to direct ions generated by the electrospray sources into and through each of the capillary inlets, providing at least two sets of primary elements having apertures, each set of elements having a receiving end and an emitting end, the primary sets of elements configured to receive a ions from the capillary inlets at the receiving ends, and providing a secondary set of elements having apertures having a receiving end and an emitting end, the secondary set of elements configured to receive said ions from the emitting end of the primary sets of elements and emit said ions from said emitting end of the secondary set of elements. The method may further include the step of providing at least one jet disturber positioned within at least one of the sets of primary elements, providing a voltage, such as a dc voltage, in the jet disturber, thereby adjusting the transmission of ions through at least one of the sets of primary elements.

  17. Electrically switched cesium ion exchange

    International Nuclear Information System (INIS)

    Lilga, M.A.; Orth, R.J.; Sukamto, J.P.H.; Schwartz, D.T.; Haight, S.M.; Genders, J.D.

    1997-04-01

    Electrically Switched Ion Exchange (ESIX) is a separation technology being developed as an alternative to conventional ion exchange for removing radionuclides from high-level waste. The ESIX technology, which combines ion exchange and electrochemistry, is geared toward producing electroactive films that are highly selective, regenerable, and long lasting. During the process, ion uptake and elution are controlled directly by modulating the potential of an ion exchange film that has been electrochemically deposited onto a high surface area electrode. This method adds little sodium to the waste stream and minimizes the secondary wastes associated with traditional ion exchange techniques. Development of the ESIX process is well underway for cesium removal using ferrocyanides as the electroactive films. Films having selectivity for perrhenate (a pertechnetate surrogate) over nitrate also have been deposited and tested. A case study for the KE Basin on the Hanford Site was conducted based on the results of the development testing. Engineering design baseline parameters for film deposition, film regeneration, cesium loading, and cesium elution were used for developing a conceptual system. Order of magnitude cost estimates were developed to compare with conventional ion exchange. This case study demonstrated that KE Basin wastewater could be processed continuously with minimal secondary waste and reduced associated disposal costs, as well as lower capital and labor expenditures

  18. Propagation of light ion beam

    International Nuclear Information System (INIS)

    Okada, Toshio; Murakami, Hiroyuki; Niu, Keishiro.

    1983-01-01

    A method of rotating ion layer is proposed as a possible driver for inertial confinement fusion for the purpose of obtaining more stable ion beam against various micro- and macroinstabilities. The analysis was carried out within the frameworks of Vlasov and fluid models. A rotating ion layer propagating in the Z-direction is considered. The beam is described by a distribution function which satisfies the Vlasov equation. The equilibrium and microstability were studied. The filamentation instability is suppressed by a magnetic field due to the rotation of ion beam. To study the properties of the equilibrium state from the macroscopic standpoint, the equation of continuity of ion beam, the equation of motion and the Maxwell equations are considered. It is shown that the macroinstability is stabilized by the magnetic field in the Z-direction. It was found that the most dangerous instability for the problem of the propagation of ion beam was able to be atabilized by using a rotating ion layer. (Kato, T.)

  19. DIVALENT ION EXCHANGE WITH ALKALI

    Energy Technology Data Exchange (ETDEWEB)

    Bunge, A.L.; Klein, G.; Radke, C.J.

    1980-05-01

    Exchange of hardness ions is important in enhanced oil recovery with chemical additives. In both micellar-polymer and caustic flooding processes, multivalent ions released from rock surfaces can interact with anionic surfactants, rendering them preferentially oil soluble and/or insoluble in water. Because hardness cations are sparingly soluble and precipitate in alkaline solutions, such solutions may be more efficient as surfactant flood preflushes than are softened brines. Multivalent ion precipitation may also occur in alkaline waterflooding. To permit design of such processes, this paper presents a chromatographic theory for simultaneous ion exchange with precipitation of divalent ions. Theoretical effluent histories and concentration profiles are presented for the cases of finite pulses and continuous injection of hydroxide ions into linear cores. Complete capture of the insoluble salt particles is assumed. Results are given for the case of instantaneous equilibration of the solution with the precipitate, as well for the case of complete nonequilibrium, in which the solid precipitate does not redissolve. The efficiency of alklaine preflushing is shown to depend on the exchange isotherm, initial divalent loading of the rock, injected pH and salinity, the solubility product of the precipitated salt, and pulse size. The effect of slug size on complete equilibrium removal of hardness ions is reduced efficiency with increasing size until a critical volume approximating continuous injection is reached. Increasing injected pH and salinity provides a more favorable response. Experimental data for Berea sandstone and an argillaceous sand compare favorably with the proposed theory.

  20. Laser induced fluorescence of trapped molecular ions

    Energy Technology Data Exchange (ETDEWEB)

    Grieman, F.J.

    1979-10-01

    An experimental apparatus for obtaining the optical spectra of molecular ions is described. The experimental technique includes the use of three dimensional ion trapping, laser induced fluorescence, and gated photon counting methods. The ions, which are produced by electron impact, are confined in a radio-frequency quadrupole ion trap of cylindrical design. Because the quadrupole ion trap allows mass selection of the molecular ion desired for study, the analysis of the spectra obtained is greatly simplified. The ion trap also confines the ions to a region easily probed by a laser beam. 18 references.

  1. Laser induced fluorescence of trapped molecular ions

    International Nuclear Information System (INIS)

    Grieman, F.J.

    1979-10-01

    An experimental apparatus for obtaining the optical spectra of molecular ions is described. The experimental technique includes the use of three dimensional ion trapping, laser induced fluorescence, and gated photon counting methods. The ions, which are produced by electron impact, are confined in a radio-frequency quadrupole ion trap of cylindrical design. Because the quadrupole ion trap allows mass selection of the molecular ion desired for study, the analysis of the spectra obtained is greatly simplified. The ion trap also confines the ions to a region easily probed by a laser beam. 18 references

  2. Heavy ion elastic scatterings

    International Nuclear Information System (INIS)

    Mermaz, M.C.

    1984-01-01

    Diffraction and refraction play an important role in particle elastic scattering. The optical model treats correctly and simultaneously both phenomena but without disentangling them. Semi-classical discussions in terms of trajectories emphasize the refractive aspect due to the real part of the optical potential. The separation due to to R.C. Fuller of the quantal cross section into two components coming from opposite side of the target nucleus allows to understand better the refractive phenomenon and the origin of the observed oscillations in the elastic scattering angular distributions. We shall see that the real part of the potential is responsible of a Coulomb and a nuclear rainbow which allows to determine better the nuclear potential in the interior region near the nuclear surface since the volume absorption eliminates any effect of the real part of the potential for the internal partial scattering waves. Resonance phenomena seen in heavy ion scattering will be discussed in terms of optical model potential and Regge pole analysis. Compound nucleus resonances or quasi-molecular states can be indeed the more correct and fundamental alternative

  3. Ultrarelativistic heavy ions

    International Nuclear Information System (INIS)

    Pugh, H.G.

    1980-12-01

    Studies with ultrarelativistic heavy ions combine aspects of cosmic ray physics, particle physics, nuclear physics, astrophysics and cosmogenesis. The leading theoretical concerns are the behavior of matter at very high-energy density and flux, the general behavior of space time in collisions, relativistic nuclear theory, and quantum chromodynamics. The field has developed over a period of more than thirty years, since the first observation of heavy nuclei in cosmic rays and the major developments of understanding of high-energy collisions made by Fermi and Landau in the early fifties. In the late sixties the discovery of the parton content of nucleons was rapidly followed by a great extension of high-energy collision phenomenology at the CERN ISR and subsequent confirmation of the QCD theory. In parallel the study of p-nucleus and nucleus-nucleus collisions at very high energies, especially at the CERN PS, Fermilab and the Bevalac, and in cosmic rays demonstrated that studies involving the nucleus opened up a new dimension in studies of the hadronic interaction. It is now at a high level of interest on an international scale, with major new accelerators being proposed to dedicate to this kind of study

  4. Heavy ion activation analysis

    International Nuclear Information System (INIS)

    Lass, B.D.; Roche, N.G.; Sanni, A.O.; Schweikert, E.A.; Ojo, J.F.

    1982-01-01

    A report on radioactivation with ion beams of 3 6 Li and 14 N is presented with some analytical applications: the determination of C via 12 C( 6 Li,αn) 13 N; the determination of Li and Be, using 14 N activation. Next, examples, with limitations in selectivity. The detection limits using a 1 μA h of activation irradiation are 5 ppm for C and 1 ppm for Li or Be. With 9 Be suitable for analytical applications are: sup(10,11)B( 9 Be,xn) 18 F and 14 N( 9 Be,αn) 18 F. Assuming a 1 μA h irradiation the detection limits for N and B are 1.5 ng and 0.5 ng, respectively, using a 7.8 MeV 9 Be beam. For activation with 12 C, experimental results with 12 MeV 12 C beam demonstrate that the beam is best suited for 7 Li analysis by the reaction 7 Li( 12 C,n) 18 F. The detection limit for a 1 μA h irradiation is 1 ng and the only other low Z elements activated are B and C. Finally, 12 C radioactivation was further combined with autoradiography for positional analysis. The spatial resolution of the technique was estimated to be 40 μm for an exposure corresponding to 6x10 5 disintegrations. As low as 10 -12 g of Li was readily detected by autoradiography. (author)

  5. Relativistic heavy ion research

    International Nuclear Information System (INIS)

    1992-01-01

    Experimental work is reported on the following topics: transverse energy production in 10.7-GeV/c/u Au on Au collisions; first results on delta ray production and charged particle multiplicities with the Au beam at 10.7 GeV/c/A; preliminary studies on the feasibility of flow measurement with the E814 participant calorimeter; preliminary results from the E877 telescope; and low-p t baryon distribution in Si+Al, Pb collisions at the AGS. Then the status of the Hadronic Calorimeter project of AGS Experiment E864 (ECOS--Exotic Composite Object Spectrometer) is reviewed. Next, the same is done for work of the STAR RHIC collaboration (Silicon Vertex Tracker (SVT) project evolution and development in FY92, SVT software results from 1992, SVT instrumentation, FY93 SVT pion test beam). The instrumentation section deals with the design and installation of a target rapidity telescope for BNL experiment 814/877 and a repair scheme for the E814/E877 participant calorimeter. Finally, the theory part addresses bosonic kinetics: thermalization of mesons and the pion p perpendicular spectrum in ultrarelativistic heavy-ion collisions and non-equilibrium properties of hadronic mixtures

  6. LHC Report: Ion Age

    CERN Multimedia

    John Jowett for the LHC team

    2013-01-01

    The LHC starts the New Year facing a new challenge: proton-lead collisions in the last month before the shutdown in mid-February.    Commissioning this new and almost unprecedented mode of collider operation is a major challenge both for the LHC and its injector chain. Moreover, it has to be done very quickly to achieve a whole series of physics goals, requiring modifications of the LHC configuration, in a very short time. These include a switch of the beam directions halfway through the run, polarity reversals of the ALICE spectrometer magnet and Van der Meer scans.    The Linac3 team kept the lead source running throughout the end-of-year technical stop, and recovery of the accelerator complex was very quick. New proton and lead beams were soon ready, with a bunch filling pattern that ensures they will eventually match up in the LHC. The LEIR machine has even attained a new ion beam intensity record.  On Friday 11 January the first single bunches o...

  7. Plasma ion sources and ion beam technology inmicrofabrications

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Lili [Univ. of California, Berkeley, CA (United States)

    2007-01-01

    For over decades, focused ion beam (FIB) has been playing a very important role in microscale technology and research, among which, semiconductor microfabrication is one of its biggest application area. As the dimensions of IC devices are scaled down, it has shown the need for new ion beam tools and new approaches to the fabrication of small-scale devices. In the meanwhile, nanotechnology has also deeply involved in material science research and bioresearch in recent years. The conventional FIB systems which utilize liquid gallium ion sources to achieve nanometer scale resolution can no longer meet the various requirements raised from such a wide application area such as low contamination, high throughput and so on. The drive towards controlling materials properties at nanometer length scales relies on the availability of efficient tools. In this thesis, three novel ion beam tools have been developed and investigated as the alternatives for the conventional FIB systems in some particular applications. An integrated focused ion beam (FIB) and scanning electron microscope (SEM) system has been developed for direct doping or surface modification. This new instrument employs a mini-RF driven plasma source to generate focused ion beam with various ion species, a FEI two-lens electron (2LE) column for SEM imaging, and a five-axis manipulator system for sample positioning. An all-electrostatic two-lens column has been designed to focus the ion beam extracted from the source. Based on the Munro ion optics simulation, beam spot sizes as small as 100 nm can be achieved at beam energies between 5 to 35 keV if a 5 μm-diameter extraction aperture is used. Smaller beam spot sizes can be obtained with smaller apertures at sacrifice of some beam current. The FEI 2LE column, which utilizes Schottky emission, electrostatic focusing optics, and stacked-disk column construction, can provide high-resolution (as small as 20 nm) imaging capability, with fairly long working distance (25

  8. Plasma ion sources and ion beam technology in microfabrications

    International Nuclear Information System (INIS)

    Ji, Lili

    2007-01-01

    For over decades, focused ion beam (FIB) has been playing a very important role in microscale technology and research, among which, semiconductor microfabrication is one of its biggest application area. As the dimensions of IC devices are scaled down, it has shown the need for new ion beam tools and new approaches to the fabrication of small-scale devices. In the meanwhile, nanotechnology has also deeply involved in material science research and bioresearch in recent years. The conventional FIB systems which utilize liquid gallium ion sources to achieve nanometer scale resolution can no longer meet the various requirements raised from such a wide application area such as low contamination, high throughput and so on. The drive towards controlling materials properties at nanometer length scales relies on the availability of efficient tools. In this thesis, three novel ion beam tools have been developed and investigated as the alternatives for the conventional FIB systems in some particular applications. An integrated focused ion beam (FIB) and scanning electron microscope (SEM) system has been developed for direct doping or surface modification. This new instrument employs a mini-RF driven plasma source to generate focused ion beam with various ion species, a FEI two-lens electron (2LE) column for SEM imaging, and a five-axis manipulator system for sample positioning. An all-electrostatic two-lens column has been designed to focus the ion beam extracted from the source. Based on the Munro ion optics simulation, beam spot sizes as small as 100 nm can be achieved at beam energies between 5 to 35 keV if a 5 (micro)m-diameter extraction aperture is used. Smaller beam spot sizes can be obtained with smaller apertures at sacrifice of some beam current. The FEI 2LE column, which utilizes Schottky emission, electrostatic focusing optics, and stacked-disk column construction, can provide high-resolution (as small as 20 nm) imaging capability, with fairly long working distance

  9. The ions displacement through glasses

    International Nuclear Information System (INIS)

    Sevegnani, F.X.

    1980-01-01

    A method to introduce sodium, potassium, lithium, calcium, iron and other ions in vacuum or gas light bulb by mean of a strong stationay electric field. The experiments showed that the mass deposited inside the bulbs obey Faraday's law of electrolysis, although the process of mass transfer is not that of a conventional electrolysis. A method which allows to show that hydrogen ions do not penetrate the glass structure is also described. Using radioactive tracers, it is shown that heavy ions, such PO 4 --- do not penetrate the glass structure. The vitreous state and the glass properties were studied for interpreting experimental results. (Author) [pt

  10. Intense beams of light ions

    International Nuclear Information System (INIS)

    Camarcat, Noel

    1985-01-01

    Results of experiments performed in order to accelerate intense beams of light and heavier ions are presented. The accelerating diodes are driven by existing pulsed power generators. Optimization of the generator structure is described in chapter I. Nuclear diagnostics of the accelerated light ion beams are presented in chapter II. Chapter III deals with the physics of intense charged particle beams. The models developed are applied to the calculation of the performances of the ion diodes described in the previous chapters. Chapter IV reports preliminary results on a multiply ionized carbon source driven by a 0.1 TW pulsed power generator. (author) [fr

  11. Prospects for ion beam fusion

    Energy Technology Data Exchange (ETDEWEB)

    Martin, R.L.

    1977-01-01

    The promise of pellet fusion by high energy heavy ions has evolved very rapidly, partly because of prior pellet work in the laser and e beam programs and partly because of an inherently good match to the application. ERDA sponsored a summer study in 1976 which has had a significant impact on the direction the ion beam fusion program has evolved. Experimental R and D work has been initiated in three of the U.S. accelerator laboratories. Argonne's development program is described. This development work, if successful, should lead to a great deal of confidence that the concept of pellet fusion by high energy heavy ions is indeed practical.

  12. Review of superconducting ion linacs

    International Nuclear Information System (INIS)

    Bollinger, L.M.

    1992-01-01

    This paper summarizes the status of the technology of superconducting (SC) linacs designed for the acceleration of ions. The emphasis is on the technical issues involved, with only brief descriptions of the numerous linacs now in operation or under construction. Recent developments of special interest are treated in more detail, and remaining technical challenges are outlined. The technology required for the acceleration of ions with velocity β=1 is not discussed because it is almost the same as for relativistic electrons. That is, this paper is mainly about SC linacs for low-velocity heavy ions

  13. Ion content of synaptic vesicles

    International Nuclear Information System (INIS)

    Demeter, I.; Keszthelyi, L.; Szokefalvi-Nagy, Z.; Varga, L.; Hollos-Nagy, K.; Nagy, A.

    1977-09-01

    Proton induced X-ray emission analysis measurements were performed to determine the P, S, K, Ca, Fe, Ni, Cu, and Zn ion content of presynaptic vesicles prepared from guinea-pig cortex brain. The number of different ions per single vesicle is calculated using results of the additional protein content determinations. The ion content of cholinergic and adrenergic vesicles are compared. Some rough conclusions can be made regarding the biochemistry of vesicles on the basis of this measurements, but the elucidation of the meaning of the data needs further work which will demonstrate the value of PIXE-type investigations in similar studies. (D.P.)

  14. Amorphization of metals by ion implantation and ion beam mixing

    International Nuclear Information System (INIS)

    Rauschenbach, B.; Heera, V.

    1988-01-01

    Amorphous metallic systems can be formed either by high-fluence ion implantation of glassforming species or by irradiation of layered metal systems with inert gas ions. Both techniques and experimental examples are presented. Empirical rules are discussed which predict whether a given system can be transformed into an amorphous phase. Influence of temperature, implantation dose and pre-existing crystalline metal composition on amorphization is considered. Examples are given of the implantation induced amorphous structure, recrystallization and formation of quasicrystalline structures. (author)

  15. Ion endash ion correlations in quenched disordered media

    International Nuclear Information System (INIS)

    Bratko, D.; Chakraborty, A.K.

    1996-01-01

    Monte Carlo simulation based on Widom close-quote s test particle method is used to study the behavior of dilute ionic solutes in a quenched disordered medium with ionized obstacles. The structure of the medium is assumed to correspond to that of an ionic fluid equilibrated at certain prequenching temperature T q and permittivity ε q different from the corresponding values at the conditions of observation. The correlations among solute ions display qualitative differences from those observed in annealed systems. The ions of equal sign are attracted to domains of the disordered material characterized by charge opposite to that of the ions. The attraction of ions of the same sign to the same domains results in an apparent attractive contribution to the disorder-averaged interionic potential. At distances sufficiently exceeding the screening length pertaining to the ionized obstacles at the prequenching conditions, the disorder-induced term prevails over the direct Coulombic repulsion and a net attraction is observed. A similar mechanism leads to a long-ranged repulsion between oppositely charged ions. These findings are in agreement with earlier calculations of the disorder-averaged ion endash ion potentials based on the asymptotic Debye endash Hueckel description of the disordered medium. The simulations are also used to estimate the effects of the medium on thermodynamic properties of the embedded ionic solute. The energies and activity coefficients are found to decrease with the product of the prequenching temperature and permittivity, a phenomenon explained in terms of the increase of the potential fluctuations in the disordered medium with growing ε qTq . In spite of its global electroneutrality, the quenched medium displays a strong selectivity with respect to the valency of the solute, the tendency towards absorption increasing with the charge of the ions. (Abstract Truncated)

  16. Automated ion imaging with the NanoSIMS ion microprobe

    Science.gov (United States)

    Gröner, E.; Hoppe, P.

    2006-07-01

    Automated ion imaging systems developed for Cameca IMS3f and IMS6f ion microprobes are very useful for the analysis of large numbers of presolar dust grains, in particular with respect to the identification of rare types of presolar grains. The application of these systems is restricted to the study of micrometer-sized grains, thereby by-passing the major fraction of presolar grains which are sub-micrometer in size. The new generation Cameca NanoSIMS 50 ion microprobe combines high spatial resolution, high sensitivity, and simultaneous detection of up to 6 isotopes which makes the NanoSIMS an unprecedented tool for the analysis of presolar materials. Here, we report on the development of a fully automated ion imaging system for the NanoSIMS at MPI for Chemistry in order to extend its analytical capabilities further. The ion imaging consists of five steps: (i) Removal of surface contamination on the area of interest. (ii) Secondary ion image acquisition of up to 5 isotopes in multi-detection. (iii) Automated particle recognition in a pre-selected image. (iv) Automated measurement of all recognised particles with appropriate raster sizes and measurement times. (v) Stage movement to new area and repetition of steps (ii)-(iv).

  17. Automated ion imaging with the NanoSIMS ion microprobe

    International Nuclear Information System (INIS)

    Groener, E.; Hoppe, P.

    2006-01-01

    Automated ion imaging systems developed for Cameca IMS3f and IMS6f ion microprobes are very useful for the analysis of large numbers of presolar dust grains, in particular with respect to the identification of rare types of presolar grains. The application of these systems is restricted to the study of micrometer-sized grains, thereby by-passing the major fraction of presolar grains which are sub-micrometer in size. The new generation Cameca NanoSIMS 50 ion microprobe combines high spatial resolution, high sensitivity, and simultaneous detection of up to 6 isotopes which makes the NanoSIMS an unprecedented tool for the analysis of presolar materials. Here, we report on the development of a fully automated ion imaging system for the NanoSIMS at MPI for Chemistry in order to extend its analytical capabilities further. The ion imaging consists of five steps: (i) Removal of surface contamination on the area of interest. (ii) Secondary ion image acquisition of up to 5 isotopes in multi-detection. (iii) Automated particle recognition in a pre-selected image. (iv) Automated measurement of all recognised particles with appropriate raster sizes and measurement times. (v) Stage movement to new area and repetition of steps (ii)-(iv)

  18. Transport of heavy ions through matter within ion optical systems

    International Nuclear Information System (INIS)

    Schwab, T.

    1991-04-01

    In this thesis for the first time higher-order ion-optical calculations were connected with the whole phase-space changes of the heavy ions in passing through matter. With the developed programs and the newly proposed analytical methods atomic and nuclear interactions of the heavy ions within ion optical systems can be described realistically. The results of this thesis were applied to the conception of the fragment separator (FRS) and to the planning and preparation of experiments at the new GSI accelerator facility. Especially for the description of the ion-optical combination of FRS and the storage ring ESR the developed programs and methods proved to be necessary. A part of the applied theories on the atomic stopping could be confirmed in the framework of this thesis in an experiment with the high-resolving spectrometer SPEC at GANIL. The method of the isotopically pure separation of projectile fragments by means of magnetic analysis and the electronic energy loss could be also experimentally successfully tested at several energies (60-400 MeV/u). Furthermore in this thesis also application-related problems regarding a tumor therapy with heavy ions were solved. A concept for a medical separator (BMS) was developed, which separates light diagnosis beams isotopically purely and beyond improves the energy sharpness by means of an especially shaped (monoenergetic) stopper so that an in-situ range determination is possible with an accuracy of about one millimeter. (orig./HSI) [de

  19. Uma ferramenta para planejamento de estudos para concursos

    Directory of Open Access Journals (Sweden)

    Leonardo Pimentel

    2015-11-01

    Full Text Available De acordo com a constituição brasileira, a única forma de se tornar um empregado do governo é passar em um concurso público. O exame de conhecimento do cargo é um dos componentes mais importantes de um concurso. Estudar para esse exame é uma tarefa que requer planejamento. Um meio de obter um bom planejamento é construir uma grade de horários que relacione as matérias a serem estudadas com os respectivos horários disponíveis para o estudo. Esse tipo de problema se assemelha bastante à gerência de projetos, em que se procura estabelecer a distribuição das atividades ao longo do tempo disponível. Assim, torna-se interessante explorar a dinâmica de estudos para concursos como um projeto. O presente trabalho apresenta a ferramenta de apoio ao estudos - Passe-me, baseada no ciclo PDCA (do inglês, Plan-Do-Check-Act. Por se tratar de uma ferramenta web, o tempo de resposta para produzir uma grade de estudos é fundamental. A ferramenta faz uso de algoritmo genético para calcular a grade de horários priorizando a velocidade de resposta. A ferramenta foi avaliada em diferentes cenários de uso e obteve desempenho satisfatório durante a produção da grade de estudos.

  20. Ion manipulation method and device

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Gordon A.; Baker, Erin M.; Smith, Richard D.; Ibrahim, Yehia M.

    2017-11-07

    An ion manipulation method and device is disclosed. The device includes a pair of substantially parallel surfaces. An array of inner electrodes is contained within, and extends substantially along the length of, each parallel surface. The device includes a first outer array of electrodes and a second outer array of electrodes. Each outer array of electrodes is positioned on either side of the inner electrodes, and is contained within and extends substantially along the length of each parallel surface. A DC voltage is applied to the first and second outer array of electrodes. A RF voltage, with a superimposed electric field, is applied to the inner electrodes by applying the DC voltages to each electrode. Ions either move between the parallel surfaces within an ion confinement area or along paths in the direction of the electric field, or can be trapped in the ion confinement area.

  1. Ion exchange in analytical chemistry

    National Research Council Canada - National Science Library

    Rieman, William; Walton, Harold F

    1970-01-01

    .... In order that the users of the book may understand properly the recommended analytical methods, considerable space is devoted to the preparation, structure and properties of ion-exchange materials...

  2. Ion Cyclotron Resonance Facility (ICR)

    Data.gov (United States)

    Federal Laboratory Consortium — his facility is charged with developing and exploiting the unique capabilities of Fourier Transform Ion Cyclotron Resonance (FT-ICR) mass spectrometry, and leads the...

  3. Ion beam generation and focusing

    International Nuclear Information System (INIS)

    Miller, P.A.; Mendel, C.W.; Swain, D.W.; Goldstein, S.A.

    1975-01-01

    Calculations have shown that efficiently generated and focused ion beams could have significant advantages over electron beams in achieving ignition of inertially-confined thermonuclear fuel. Efficient ion beam generation implies use of a good ion source and suppression of net electron current. Net electron flow can be reduced by allowing electrons to reflex through a highly transparent anode or by use of transverse magnetic fields (either beam self-fields or externally applied fields). Geometric focusing can be achieved if the beam is generated by appropriately shaped electrodes. Experimental results are presented which demonstrate ion beam generation in both reflexing and pinched-flow diodes. Spherically shaped electrodes are used to concentrate a proton beam, and target response to proton deposition is studied

  4. Ion beam modification of polymers

    International Nuclear Information System (INIS)

    Sofield, C.J.; Sugden, S.; Ing, J.; Bridwell, L.B.; Wang, Y.Q.

    1993-01-01

    The implantation of polymers has received considerable attention in recent years, primarily to examine doping of conducting polymers and to increase the surface conductivity (by many orders of magnitude) of highly insulating polymers. The interest in these studies was partly motivated by possible applications to microelectronic device fabrication. More recently it has been observed that ion implantation can under some conditions lead to the formation of a hard (e.g. as hard as steel, ca. 3 MPa) and conducting surface layer. This paper will review the ion beam modification of polymers resulting from ion implantation with reference to fundamental ion-solid interactions. This leads us to examine whether or not implantation of polymers is a contradiction in terms. (Author)

  5. Micro Mercury Ion Clock (MMIC)

    Data.gov (United States)

    National Aeronautics and Space Administration — Demonstrate micro clock based on trapped Hg ions with more than 10x size reduction and power; Fractional frequency stability at parts per 1014 level, adequate for...

  6. Ion bombardment in RF photoguns

    Energy Technology Data Exchange (ETDEWEB)

    Pozdeyev,E.; Kayran, D.; Litvinenko, V. N.

    2009-05-04

    A linac-ring eRHIC design requires a high-intensity CW source of polarized electrons. An SRF gun is viable option that can deliver the required beam. Numerical simulations presented elsewhere have shown that ion bombardment can occur in an RF gun, possibly limiting lifetime of a NEA GaAs cathode. In this paper, we analytically solve the equations of motion of ions in an RF gun using the ponderomotive potential of the Rf field. We apply the method to the BNL 1/2-cell SRF photogun and demonstrate that a significant portion of ions produced in the gun can reach the cathode if no special precautions are taken. Also, the paper discusses possible mitigation techniques that can reduce the rate of ion bombardment.

  7. Modeling the Lithium Ion Battery

    Science.gov (United States)

    Summerfield, John

    2013-01-01

    The lithium ion battery will be a reliable electrical resource for many years to come. A simple model of the lithium ions motion due to changes in concentration and voltage is presented. The battery chosen has LiCoO[subscript 2] as the cathode, LiPF[subscript 6] as the electrolyte, and LiC[subscript 6] as the anode. The concentration gradient and…

  8. An ion synchrotron design program

    International Nuclear Information System (INIS)

    Yoshida, Katsuhisa; Ishi, Yoshihiro

    1995-01-01

    Ion synchrotrons have promising applications in medical and other commercial settings as well as in physics research. Mitsubishi Electric has developed a program to facilitate efficiency studies on processes such as ion injection, radio-frequency capture and acceleration, and beam extraction. The integration method used in the particle-orbit calculations maintains the symplectic characteristic of Hamilton dynamics making it possible to simulate long-term phenomena reliably. The article introduces this program and several of its applications. (author)

  9. Ion trajectories quadrupole mass filters

    International Nuclear Information System (INIS)

    Ursu, D.; Lupsa, N.; Muntean, F.

    1994-01-01

    The present paper aims at bringing some contributions to the understanding of ion motion in quadrupole mass filters. The theoretical treatment of quadrupole mass filter is intended to be a concise derivation of the important physical relationships using Mathieu functions. A simple iterative method of numerical computation has been used to simulate ion trajectories in an ideal quadrupole field. Finally, some examples of calculation are presented with the aid of computer graphics. (Author) 14 Figs., 1 Tab., 20 Refs

  10. Heavy ion therapy: Bevalac epoch

    International Nuclear Information System (INIS)

    Castro, J.R.

    1993-10-01

    An overview of heavy ion therapy at the Bevelac complex (SuperHILac linear accelerator + Bevatron) is given. Treatment planning, clinical results with helium ions on the skull base and uveal melanoma, clinical results with high-LET charged particles, neon radiotherapy of prostate cancer, heavy charged particle irradiation for unfavorable soft tissue sarcoma, preliminary results in heavy charged particle irradiation of bone sarcoma, and irradiation of bile duct carcinoma with charged particles and-or photons are all covered

  11. BNL heavy ion fusion program

    International Nuclear Information System (INIS)

    Maschke, A.W.

    1978-01-01

    A principal attraction of heavy ion fusion is that existing accelerator technology and theory are sufficiently advanced to allow one to commence the design of a machine capable of igniting thermonuclear explosions. There are, however, a number of features which are not found in existing accelerators built for other purposes. The main thrust of the BNL Heavy Ion Fusion program has been to explore these features. Longitudinal beam bunching, very low velocity acceleration, and space charge neutralization are briefly discussed

  12. Intense nonrelativistic cesium ion beam

    International Nuclear Information System (INIS)

    Lampel, M.C.

    1984-01-01

    The Heavy Ion Fusion group at Lawrence Berkeley Laboratory has constructed the One Ampere Cesium injector as a proof of principle source to supply an induction linac with a high charge density and high brightness ion beam. This is studied here. An electron beam probe was developed as the major diagnostic tool for characterizing ion beam space charge. Electron beam probe data inversion is accomplished with the EBEAM code and a parametrically adjusted model radial charge distribution. The longitudinal charge distribution was not derived, although it is possible to do so. The radial charge distribution that is derived reveals an unexpected halo of trapped electrons surrounding the ion beam. A charge fluid theory of the effect of finite electron temperature on the focusing of neutralized ion beams (Nucl Fus. 21, 529(1981)) is applied to the problem of the cesium beam final focus at the end of the injector. It is shown that the theory's predictions and assumptions are consistent with the experimental data, and that it accounts for the observed ion beam radius of approx.5 cm and the electron halo, including the determination of an electron Debye length of approx.10 cm

  13. Ion Bernstein wave heating research

    International Nuclear Information System (INIS)

    Ono, Masayuki.

    1992-03-01

    Ion Bernstein wave heating (IBWH) utilizes the ion Bernstein wave (IBW), a hot plasma wave, to carry the radio frequency (rf) power to heat tokamak reactor core. Earlier wave accessibility studies have shown that this finite-Larmor-radius (FLR) mode should penetrate into a hot dense reactor plasma core without significant attenuation. Moreover, the IBW's low phase velocity (ω/k perpendicular ∼ V Ti much-lt V α ) greatly reduces the otherwise serious wave absorption by the 3.5 MeV fusion α-particles. In addition, the property of IBW's that k perpendicular ρ i ∼ 1 makes localized bulk ion heating possible at the ion cyclotron harmonic layers. Such bulk ion heating can prove useful in optimizing fusion reactivity. In another vein, with proper selection of parameters, IBW's can be made subject to strong localized electron Landau damping near the major ion cyclotron harmonic resonance layers. This property can be useful, for example, for rf current drive in the reactor plasma core. This paper discusses this research

  14. Nuclear Spin Effect on Recombination of H3+ Ions with Electrons at 77 K

    Science.gov (United States)

    Varju, J.; Hejduk, M.; Dohnal, P.; Jílek, M.; Kotrík, T.; Plašil, R.; Gerlich, D.; Glosík, J.

    2011-05-01

    Utilizing different ratios of para to ortho H2 in normal and para enriched hydrogen, we varied the population of para-H3+ in an H3+ dominated plasma at 77 K. Absorption spectroscopy was used to measure the densities of the two lowest rotational states of H3+. Monitoring plasma decays at different populations of para-H3+ allowed us to determine the rate coefficients for binary recombination of H3+ and ortho-H3+ ions: αbinp(77K)=(1.9±0.4)×10-7cm3s-1 and αbino(77K)=(0.2±0.2)×10-7cm3s-1.

  15. Nuclear Spin Effect on Recombination of H3+ Ions with Electrons at 77 K

    International Nuclear Information System (INIS)

    Varju, J.; Hejduk, M.; Dohnal, P.; Jilek, M.; Kotrik, T.; Plasil, R.; Gerlich, D.; Glosik, J.

    2011-01-01

    Utilizing different ratios of para to ortho H 2 in normal and para enriched hydrogen, we varied the population of para-H 3 + in an H 3 + dominated plasma at 77 K. Absorption spectroscopy was used to measure the densities of the two lowest rotational states of H 3 + . Monitoring plasma decays at different populations of para-H 3 + allowed us to determine the rate coefficients for binary recombination of H 3 + and ortho-H 3 + ions: p α bin (77 K)=(1.9±0.4)x10 -7 cm 3 s -1 and o α bin (77 K)=(0.2±0.2)x 10 -7 cm 3 s -1 .

  16. Uso de bacterias sulfato-reductoras inmovilizadas para la precipitación de metales pesados

    OpenAIRE

    Vicente, Mariana Soledad

    2006-01-01

    Los objetivos de la tesis son: utilizar bacterias sulfato-reductoras para la precipitación de metales pesados; caracterizar el crecimiento de bacterias del género Desulfovibrio en distintas condiciones de cultivo; caracterizar la precipitación de iones metálicos por bacterias del género Desulfovibrio en cultivos batch; caracterizar el crecimiento de bacterias del género Desulfovibrio inmovilizadas sobre diferentes soportes inerte; caracterizar la precipitación de iones metálicos con bacterias...

  17. Masterplan para UNIMAK y Estrategias para la ciudad de Makeni

    OpenAIRE

    Bacete Cebrian, Laura

    2012-01-01

    El proyecto se desarrolla en tres escalas. Por un lado están las propuestas a nivel ciudad muy relacionadas con la siguiente escala, la de la universidad, y por último hay una escala de detalle, tanto para ciudad como para universidad. Se plantea la creación de unos nodos interconectados por los corredores verdes de la ciudad que den servicios básicos a la ciudad tales gestión de residuos, equipamientos públicos, puntos de agua, saneamiento...)

  18. A sensitive fluorescent sensor of lanthanide ions

    CERN Document Server

    Bekiari, V; Lianos, P

    2003-01-01

    A fluorescent probe bearing a diazostilbene chromophore and a benzo-15-crown-5 ether moiety is a very efficient sensor of lanthanide ions. The ligand emits strong fluorescence only in the presence of specific ions, namely lanthanide ions, while the emission wavelength is associated with a particular ion providing high sensitivity and resolution.

  19. Ion channelling in diamond

    International Nuclear Information System (INIS)

    Derry, T.E.

    1978-06-01

    Diamond is one of the most extreme cases from a channelling point of view, having the smallest thermal vibration amplitude and the lowest atomic number of commonly-encountered crystals. These are the two parameters most important for determining channelling behaviour. It is of consiberable interest therefore to see how well the theories explaining and predicting the channeling properties of other substance, succeed with diamond. Natural diamond, although the best available form for these experiments, is rather variable in its physical properties. Part of the project was devoted to considering and solving the problem of obtaining reproducible results representative of the ideal crystal. Channelling studies were performed on several good crystals, using the Rutherford backscattering method. Critical angles for proton channelling were measured for incident energies from 0.6 to 4.5 MeV, in the three most open axes and three most open planes of the diamond structure, and for α-particle channelling at 0.7 and 1.0 MeV (He + ) in the same axes and planes. For 1.0 MeV protons, the crystal temperature was varied from 20 degrees Celsius to 700 degrees Celsius. The results are presented as curves of backscattered yield versus angle in the region of each axis or plane, and summarised in the form of tables and graphs. Generally the critical angles, axial minimum yields, and temperature dependence are well predicted by the accepted theories. The most valuable overall conclusion is that the mean thermal vibration amplitude of the atoms in a crytical determines the critical approach distance to the channel walls at which an ion can remain channelled, even when this distance is much smaller than the Thomas-Fermi screening distance of the atomic potential, as is the case in diamond. A brief study was made of the radiation damage caused by α-particle bombardment, via its effect on the channelling phenomenon. It was possible to hold damage down to negligible levels during the

  20. Development of a dosimetric system for the quality control of breast cancer treatments; Desenvolvimento de um sistema dosimetrico para o controle de qualidade nos tratamentos de cancer de mama

    Energy Technology Data Exchange (ETDEWEB)

    Chaves, Roberio C.; Crispim, Verginia R., E-mail: rchaves@nuclear.ufrj.br, E-mail: verginia@nuclear.ufrj.br [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/lUFRJ), RJ (Brazil). Programa de Pos-Graduacao em Engenharia Nuclear; Rosa, Luiz A.R. da, E-mail: Irosa@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN), Rio de Janeiro, RJ (Brazil); Santos, Delano B.V., E-mail: delano@inca.gov.br [Instituto Nacional do Cancer (INCA/MS), Rio de Janeiro, RJ (Brazil)

    2013-11-01

    A system for evaluating the values of absorbed dose in breast teletherapy was developed, using thermoluminescent dosimeters (TLD-100), to compare them to those provided by Therapy planning system. A breast phantom was made to distribute the dosimeters TL shaped chip in breast volume and irradiate it under the same conditions of planning. Three different techniques of teletherapy were considered: one with irradiation from a therapy unit of {sup 60}Co and two with an X-ray beam coming from a 6 MV linear accelerator. Doses measures allowed checking that the performance of the quality control system used in breast cancer treatment is appropriate, since the planned doses differed about 1.5% of the responses provided by TL dosimeters.

  1. Observations of strong ion-ion correlations in dense plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Ma, T.; Fletcher, L.; Pak, A.; Chapman, D. A.; Falcone, R. W.; Fortmann, C.; Galtier, E.; Gericke, D. O.; Gregori, G.; Hastings, J.; Landen, O. L.; Le Pape, S.; Lee, H. J.; Nagler, B.; Neumayer, P.; Turnbull, D.; Vorberger, J.; White, T. G.; Wünsch, K.; Zastrau, U.; Glenzer, S. H.; Döppner, T.

    2014-05-01

    Using simultaneous spectrally, angularly, and temporally resolved x-ray scattering, we measure the pronounced ion-ion correlation peak in a strongly coupled plasma. Laser-driven shock-compressed aluminum at ~3× solid density is probed with high-energy photons at 17.9 keV created by molybdenum He-α emission in a laser-driven plasma source. The measured elastic scattering feature shows a well-pronounced correlation peak at a wave vector of k=4k=4Å-1. The magnitude of this correlation peak cannot be described by standard plasma theories employing a linear screened Coulomb potential. Advanced models, including a strong short-range repulsion due to the inner structure of the aluminum ions are however in good agreement with the scattering data. These studies have demonstrated a new highly accurate diagnostic technique to directly measure the state of compression and the ion-ion correlations. We have since applied this new method in single-shot wave-number resolved S(k) measurements to characterize the physical properties of dense plasmas.

  2. Ion beam analysis fundamentals and applications

    CERN Document Server

    Nastasi, Michael; Wang, Yongqiang

    2015-01-01

    Ion Beam Analysis: Fundamentals and Applications explains the basic characteristics of ion beams as applied to the analysis of materials, as well as ion beam analysis (IBA) of art/archaeological objects. It focuses on the fundamentals and applications of ion beam methods of materials characterization.The book explains how ions interact with solids and describes what information can be gained. It starts by covering the fundamentals of ion beam analysis, including kinematics, ion stopping, Rutherford backscattering, channeling, elastic recoil detection, particle induced x-ray emission, and nucle

  3. Taller para desarrollar la creatividad

    OpenAIRE

    MARTÍNEZ GUEROLA, BEATRIZ

    2015-01-01

    [ES] Partimos de la base de que la creatividad es una capacidad realmente valiosa, no solo para el ámbito artístico, si no para cualquier aspecto de la vida. Este proyecto está enfocado a un taller diseñado para que a partir de técnicas de expresión gráfico-plásticas podamos estimular y desarrollar la creatividad, principalmente en niños de tercer ciclo de primaria. Con este proyecto relacionamos el arte y la creatividad que se asocia a esté con la educación. Martínez Guerola, B. (2015). T...

  4. Ion Beam Therapy in Europe

    International Nuclear Information System (INIS)

    Kraft, Gerhard

    2009-01-01

    At present, seven facilities in Europe treat deep-seated tumors with particle beams, six with proton beams and one with carbon ions. Three of these facilities are in Moscow, St. Petersburg and Dubna, Russia. Other facilities include the TSL Uppsala, Sweden, CPO Orsay, France, and PSI Villigen, Switzerland, all for proton therapy, and GSI, Darmstadt, Germany, which utilizes carbon ions only. But only two of these facilities irradiate with scanned ion beams: the Paul Scherer Institute (PSI), Villigen (protons) and the Gesellschaft fuer Schwerionenforschung (GSI), Darmstadt. These two facilities are experimental units within physics laboratories and have developed the technique of intensity-modulated beam scanning in order to produce irradiation conforming to a 3-D target. There are three proton centers presently under construction in Munich, Essen and Orsay, and the proton facility at PSI has added a superconducting accelerator connected to an isocentric gantry in order to become independent of the accelerator shared with the physics research program. The excellent clinical results using carbon ions at National Institute of Radiological Science (NIRS) in Chiba and GSI have triggered the construction of four new heavy-ion therapy projects (carbon ions and protons), located in Heidelberg, Pavia, Marburg and Kiel. The projects in Heidelberg and Pavia will begin patient treatment in 2009, and the Marburg and Kiel projects will begin in 2010 and 2011, respectively. These centers use different accelerator designs but have the same kind of treatment planning system and use the same approach for the calculation of the biological effectiveness of the carbon ions as developed at GSI [1]. There are many other planned projects in the works. Do not replace the word ''abstract,'' but do replace the rest of this text. If you must insert a hard line break, please use Shift+Enter rather than just tapping your ''Enter'' key. You may want to print this page and refer to it as a style

  5. Medical heavy ion accelerator proposals

    International Nuclear Information System (INIS)

    Gough, R.A.

    1985-05-01

    For several decades, accelerators designed primarily for research in nuclear and high energy physics have been adapted for biomedical research including radiotherapeutic treatment of human diseases such as pituitary disorders, cancer, and more recently, arteriovascular malformations. The particles used in these treatments include pions, protons and heavier ions such as carbon, neon, silicon and argon. Maximum beam energies must be available to penetrate into an equivalent of about 30 cm of water, requiring treatment beams of 250 to 1000 MeV/nucleon. Certain special treatments of superficial melanoma, however, require that beam energies as low as 70 MeV/nucleon also be available. Intensities must be adequate to complete a 100 rad treatment fraction in about 1 minute. For most heavy ion treatments, this corresponds to 10 7 -10 9 ions/second at the patient. Because this research is best conducted in a dedicated, hospital-based facility, and because of the clinical need for ultra-high reliability, the construction of new and dedicated facilities has been proposed. Heavy ion accelerators can provide a variety of ions and energies, permitting treatment plans that exploit the properties of the ion best suited to each individual treatment, and that employ radioactive beams (such as 11 C and 19 Ne) to precisely confirm the dose localization. The favored technical approach in these proposals utilizes a conventional, strong-focusing synchrotron capable of fast switching between ions and energies, and servicing multiple treatment rooms. Specialized techniques for shaping the dose to conform to irregularly-shaped target volumes, while simultaneously sparing surrounding, healthy tissue and critical structures, are employed in each treatment room, together with the sophisticated dosimetry necessary for verification, monitoring, and patient safety. 3 refs., 8 figs

  6. Fundamental processes determining the highly charged ion production in ECR ion sources

    International Nuclear Information System (INIS)

    Shirkov, G.D.

    1992-01-01

    The ion confinement and loss conditions in the open magnetic traps have been analyzed in this article. In EGRIS the the ions are confined in the negative potential well. The simultaneous application of ion cooling and pulse regime is proposed for pulse injection of highly charged ions in heavy ion accelerators and storage rings. 14 refs.; 3 figs

  7. Ion channelopathies in functional GI disorders

    OpenAIRE

    Beyder, Arthur; Farrugia, Gianrico

    2016-01-01

    In the gastrointestinal (GI) tract, abnormalities in secretion, absorption, motility, and sensation have been implicated in functional gastrointestinal disorders (FGIDs). Ion channels play important roles in all these GI functions. Disruptions of ion channels' ability to conduct ions can lead to diseases called ion channelopathies. Channelopathies can result from changes in ion channel biophysical function or expression due to mutations, posttranslational modification, and accessory protein m...

  8. Negative ion formation and neutralization processes, (1)

    International Nuclear Information System (INIS)

    Sugiura, Toshio

    1982-01-01

    This review has been made preliminary for the purpose of contribute to the plasma heating by ''negative ion based neutral beam injection'' in the magnetic confinement fusion reactor. A compilation includes the survey of the general processes of negative ion formation, the data of the cross section of H - ion formation and the neutralization of H - ion, and some of new processes of H - ion formation. The data of cross section are mainly experimental, but partly include the results of theoretical calculation. (author)

  9. Estrategias Digitales Para Los Negocios

    OpenAIRE

    Sánchez, Nicolás David; Porras, María Paula

    2016-01-01

    Este trabajo es para fines institucionales de la Universidad del Rosario. A lo largo del segundo semestre del año 2016 entendimos la importancia de los medios digitales para las empresas, por lo cual el profesor Juan Manuel Méndez nos dio el caso de las bicicletas de Nairo Quintana con el cual teníamos que desarrollar un plan de estrategias digitales acorde con el contexto actual del sector de las bicicletas, en donde se creara y desarrollara la marca de la agencia digital creada por los estu...

  10. CODIFEXA - Colecciones Digitales para Exactas

    OpenAIRE

    Olguín, Luis Alberto; Klenzi, Raúl O.

    2013-01-01

    La construcción de repositorios institucionales (RI) por parte de facultades de universidades argentinas es cada vez más significativa, pero para que este tipo de emprendimientos – generalmente con presupuestos ajustados – tenga sustentabilidad en el tiempo es necesario “mostrar que es útil” para la institución - los docentes en particular - en el sentido que permite aumentar la visibilidad de la producción científica local y por ende el impacto entre sus pares. El proyecto que aquí descri...

  11. Ion-ion correlation attraction in a molecular solvent.

    Science.gov (United States)

    Pegado, Luís; Jönsson, Bo; Wennerström, Håkan

    2008-11-14

    We have performed Monte Carlo simulations for two like-charged infinite plates with counterions and solvent in between. The solvent is described at the primitive model (PM) level and also as a Stockmayer fluid. Both descriptions share the same qualitative ion correlation picture. At sufficiently high coupling, the pressure between the plates shows an attractive minimum, which is lost or reduced upon decreasing counterion valency, surface charge density, or increasing the screening. The pressure profiles become more oscillatory with higher density, which masks the ion-ion correlation attraction. An interpretation in terms of interaction free energies rather than pressures clarifies the picture. Analyzing the different contributions to the pressure gives further support to the conclusions; the same components are responsible for the same effect in the PM and in the molecular solvent.

  12. Proton-bound cluster ions in ion mobility spectrometry

    Science.gov (United States)

    Ewing, R. G.; Eiceman, G. A.; Stone, J. A.

    1999-01-01

    Gaseous oxygen and nitrogen bases, both singly and as binary mixtures, have been introduced into ion mobility spectrometers to study the appearance of protonated molecules, and proton-bound dimers and trimers. At ambient temperature it was possible to simultaneously observe, following the introduction of molecule A, comparable intensities of peaks ascribable to the reactant ion (H2O)nH+, the protonated molecule AH+ and AH+ H2O, and the symmetrical proton bound dimer A2H+. Mass spectral identification confirmed the identifications and also showed that the majority of the protonated molecules were hydrated and that the proton-bound dimers were hydrated to a much lesser extent. No significant peaks ascribable to proton-bound trimers were obtained no matter how high the sample concentration. Binary mixtures containing molecules A and B, in some cases gave not only the peaks unique to the individual compounds but also peaks due to asymmetrical proton bound dimers AHB+. Such ions were always present in the spectra of mixtures of oxygen bases but were not observed for several mixtures of oxygen and nitrogen bases. The dimers, which were not observable, notable for their low hydrogen bond strengths, must have decomposed in their passage from the ion source to the detector, i.e. in a time less than approximately 5 ms. When the temperature was lowered to -20 degrees C, trimers, both homogeneous and mixed, were observed with mixtures of alcohols. The importance of hydrogen bond energy, and hence operating temperature, in determining the degree of solvation of the ions that will be observed in an ion mobility spectrometer is stressed. The possibility is discussed that a displacement reaction involving ambient water plays a role in the dissociation.

  13. Implementation of a dosimetry service for the occupationally exposed personnel of the ESFM-IPN; Implementacion de un servicio de dosimetria para el personal ocupacionalmente expuesto de la ESFM-IPN

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez A, Y. [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan No. 779, Col. Narvarte, 03020 Mexico D. F. (Mexico); Sanchez R, A. A. [IPN, Escuela Superior de Fisica y Matematicas, U. P. Adolfo Lopez Mateos, Edif. 9, 07738 Mexico D. F. (Mexico); Ceron R, P. V.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia y Tecnologia Avanzada, Unidad Legaria, Av. Legaria No. 694, 11500 Mexico D. F. (Mexico); Vega C, H. R., E-mail: yamani.hernandez@cnsns.gob.mx [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-10-15

    Because the ionizing radiations handling implies a risk for the health, is necessary to take a control of the radiation quantity that the occupationally exposed personnel receives during their daily work with ionizing radiations. For this purpose there are several types of dosimetry and companies that provide the service, but taking advantage that the Escuela Superior de Fisica y Matematicas del Instituto Politecnico Nacional (ESFM-IPN) possesses a thermoluminescence equipment (Tl) was decided to develop a personnel dosimetry service for gammas, with thermoluminescent glasses of type TLD-100. First one carries out a glasses characterization, for which the glasses were washed with a methyl alcohol solution, without rubbing them for not damaging them; after the drying, they were subjected to a temperature of 400 C during one hour and later on 100 grades C for two hours in order to erasing them the bottom information that they could have. 200 glasses were exposed to gamma radiation coming from a Cobalt 60 source property of ESFM-IPN in order to selecting the glasses that had a response whose precision was inside a standard deviation. Of this characterization 80 dosimeters were selected that had better response according to the obtained readings as well as of their shine curves. These selected TLD-100 glasses were irradiated to different dose of gamma radiation and with those readings it was built a dose response curve in m R against readings of electric load in pick Coulombs (pCou). The response curve was a direct line or calibration curve. As final exercise some glasses of this selected lot were subjected to irradiation dose not known by the person that carried out the readings and this way was proven that the results were appropriate with the calibration curve. Finally these dosimeters were placed in port-dosimeters and erased guides of dosimeters, of equipment use and dosimeters lecture were also elaborated. (Author)

  14. Maskless, resistless ion beam lithography

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Qing [Univ. of California, Berkeley, CA (United States)

    2003-01-01

    As the dimensions of semiconductor devices are scaled down, in order to achieve higher levels of integration, optical lithography will no longer be sufficient for the needs of the semiconductor industry. Alternative next-generation lithography (NGL) approaches, such as extreme ultra-violet (EUV), X-ray, electron-beam, and ion projection lithography face some challenging issues with complicated mask technology and low throughput. Among the four major alternative NGL approaches, ion beam lithography is the only one that can provide both maskless and resistless patterning. As such, it can potentially make nano-fabrication much simpler. This thesis investigates a focused ion beam system for maskless, resistless patterning that can be made practical for high-volume production. In order to achieve maskless, resistless patterning, the ion source must be able to produce a variety of ion species. The compact FIB system being developed uses a multicusp plasma ion source, which can generate ion beams of various elements, such as O2+, BF2+, P+ etc., for surface modification and doping applications. With optimized source condition, around 85% of BF2+, over 90% of O2+ and P+ have been achieved. The brightness of the multicusp-plasma ion source is a key issue for its application to maskless ion beam lithography. It can be substantially improved by optimizing the source configuration and extractor geometry. Measured brightness of 2 keV He+ beam is as high as 440 A/cm2 • Sr, which represents a 30x improvement over prior work. Direct patterning of Si thin film using a focused O2+ ion beam has been investigated. A thin surface oxide film can be selectively formed using 3 keV O2+ ions with the dose of 1015 cm-2. The oxide can then serve as a hard mask for patterning of the Si film. The

  15. Maskless, resistless ion beam lithography

    International Nuclear Information System (INIS)

    Ji, Qing

    2003-01-01

    As the dimensions of semiconductor devices are scaled down, in order to achieve higher levels of integration, optical lithography will no longer be sufficient for the needs of the semiconductor industry. Alternative next-generation lithography (NGL) approaches, such as extreme ultra-violet (EUV), X-ray, electron-beam, and ion projection lithography face some challenging issues with complicated mask technology and low throughput. Among the four major alternative NGL approaches, ion beam lithography is the only one that can provide both maskless and resistless patterning. As such, it can potentially make nano-fabrication much simpler. This thesis investigates a focused ion beam system for maskless, resistless patterning that can be made practical for high-volume production. In order to achieve maskless, resistless patterning, the ion source must be able to produce a variety of ion species. The compact FIB system being developed uses a multicusp plasma ion source, which can generate ion beams of various elements, such as O 2 + , BF 2 + , P + etc., for surface modification and doping applications. With optimized source condition, around 85% of BF 2 + , over 90% of O 2 + and P + have been achieved. The brightness of the multicusp-plasma ion source is a key issue for its application to maskless ion beam lithography. It can be substantially improved by optimizing the source configuration and extractor geometry. Measured brightness of 2 keV He + beam is as high as 440 A/cm 2 · Sr, which represents a 30x improvement over prior work. Direct patterning of Si thin film using a focused O 2 + ion beam has been investigated. A thin surface oxide film can be selectively formed using 3 keV O 2 + ions with the dose of 10 15 cm -2 . The oxide can then serve as a hard mask for patterning of the Si film. The process flow and the experimental results for directly patterned poly-Si features are presented. The formation of shallow pn-junctions in bulk silicon wafers by scanning focused P

  16. THOR Ion Mass Spectrometer (IMS)

    Science.gov (United States)

    Retinò, Alessandro

    2017-04-01

    Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. The Ion Mass Spectrometer (IMS) onboard THOR will provide the first high-time resolution measurements of mass-resolved ions in near-Earth space, focusing on hot ions in the foreshock, shock and magnetosheath turbulent regions. These measurements are required to study how kinetic-scale turbulent fluctuations heat and accelerate different ion species. IMS will measure the full three-dimensional distribution functions of main ion species (H+, He++, O+) in the energy range 10 eV/q to 30 keV/q with energy resolution DE/E down to 10% and angular resolution down to 11.25˚ . The time resolution will be 150 ms for O+, 300 ms for He++ and ˜ 1s for O+, which correspond to ion scales in the the foreshock, shock and magnetosheath regions. Such high time resolution is achieved by mounting four identical IMS units phased by 90˚ in the spacecraft spin plane. Each IMS unit combines a top-hat electrostatic analyzer with deflectors at the entrance together with a time-of-flight section to perform mass selection. Adequate mass-per-charge resolution (M/q)/(ΔM/q) (≥ 8 for He++ and ≥ 3 for O+) is obtained through a 6 cm long Time-of-Flight (TOF) section. IMS electronics includes a fast sweeping high voltage board that is required to make measurements at high cadence. Ion detection includes Micro Channel Plates (MCPs) combined with Application-Specific Integrated Circuits (ASICs) for charge amplification and discrimination and a discrete Time-to-Amplitude Converter (TAC) to determine the ion time of flight. A processor board will be used to for ion events formatting and will interface with the Particle Processing Unit (PPU), which will perform data processing for THOR particle detectors. The IMS instrument is being designed and will be built and calibrated by an international consortium of scientific institutes from France, USA, Germany and Japan and Switzerland.

  17. Characterization of ISOLDE ion source and ion source chemistry

    CERN Document Server

    Barbeau, Marion

    2014-01-01

    This report presents results of measurements made with the ISOLDE OFF-LINE mass separator [1]. The first part shows measurements of the ionization characteristics of noble gases in a VADIS ion source. The goal of the measurements was to determine the dependency of the extractable current of first and second noble gases ions with the electron energy. In the second part, investigation on in-target chemistry are presented. Here, the effect of injected sulfur hexafluoride ($SF_6$) on the release of oxygen from aluminium oxide ($Al_2 O_3$) was studied.

  18. Industrial ion sources broadbeam gridless ion source technology

    CERN Document Server

    Zhurin, Viacheslav V

    2012-01-01

    Due to the large number of uses of ion sources in academia and industry, those who utilize these sources need up to date and coherent information to keep themselves abreast of developments and options, and to chose ideal solutions for quality and cost-effectiveness. This book, written by an author with a strong industrial background and excellent standing, is the comprehensive guide users and developers of ion sources have been waiting for. Providing a thorough refresher on the physics involved, this resource systematically covers the source types, components, and the operational parameters.

  19. Beam divergence and ion current in multiaperture ion sources

    International Nuclear Information System (INIS)

    Ott, W.; Penningsfeld, F.P.

    1992-03-01

    Two different measurements of the divergence of high-current ion beams formed in a multiaperture ion source have been made. The current dependence of both measurements shows characteristic differences which are explained as a result of an inhomogeneity of the current density across the emission area. The model of Coupland et al. with a spherical beam geometry in the acceleration gap is reexamined. It is shown that a rigorous application of this model gives a beamlet defocusing in the decel electrode which is stronger by a factor of 1.35 than assumed hitherto. The implications on offset steering are discussed. (orig.)

  20. SM-1 negative ion source

    International Nuclear Information System (INIS)

    Huang Zhenjun; Wang Jianzhen

    1987-01-01

    The working principle and characteristics of SM-1 Negative Ion Source is mainly introduced. In the instrument, there is a device to remove O 3 . This instrument can keep high density of negative ions which is generated by the electrical coronas setting out electricity at negative high voltage and can remove the O 3 component which is harmful to the human body. The density of negative ions is higher than 2.5 x 10 6 p./cm 3 while that of O 3 components is less than 1 ppb at the distance of 50 cm from the panel of the instrument. The instrument sprays negative ions automatically without the help of electric fan, so it works noiselessly. It is widely used in national defence, industry, agriculture, forestry, stock raising, sidelines and in the places with an equipment of low density of negative ion or high concentration of O 3 components. Besides, the instrument may also be used to treat diseases, to prevent against rot, to arrest bacteria, to purify air and so on

  1. Ion beam processes in Si

    International Nuclear Information System (INIS)

    Holland, O.W.; Narayan, J.; Fathy, D.

    1984-07-01

    Observation of the effects of implants of energetic ions at high dose rates into Si have produced some exciting and interesting results. The mechanism whereby displacement damage produced by ions self-anneals during high dose rate implantation is discussed. It is shown that ion beam annealing (IBA) offers in certain situations unique possibilities for damage annealing. Annealing results of the near surface in Si with a buried oxide layer, formed by high dose implantation, are presented in order to illustrate the advantages offered by IBA. It is also shown that ion irradiation can stimulate the epitaxial recrystallization of amorphous overlayers in Si. The nonequilibrium alloying which results from such epitaxial processes is discussed as well as mechanisms which limit the solid solubility during irradiation. Finally, a dose rate dependency for the production of stable damage by ion irradiation at a constant fluence has been observed. For low fluence implants, the amount of damage is substantially greater in the case of high flux rather than low flux implantation

  2. Microscale ion trap mass spectrometer

    Science.gov (United States)

    Ramsey, J. Michael; Witten, William B.; Kornienko, Oleg

    2002-01-01

    An ion trap for mass spectrometric chemical analysis of ions is delineated. The ion trap includes a central electrode having an aperture; a pair of insulators, each having an aperture; a pair of end cap electrodes, each having an aperture; a first electronic signal source coupled to the central electrode; a second electronic signal source coupled to the end cap electrodes. The central electrode, insulators, and end cap electrodes are united in a sandwich construction where their respective apertures are coaxially aligned and symmetric about an axis to form a partially enclosed cavity having an effective radius r.sub.0 and an effective length 2z.sub.0, wherein r.sub.0 and/or z.sub.0 are less than 1.0 mm, and a ratio z.sub.0 /r.sub.0 is greater than 0.83.

  3. Rotation sensing with trapped ions

    Science.gov (United States)

    Campbell, W. C.; Hamilton, P.

    2017-03-01

    We present a protocol for rotation measurement via matter-wave Sagnac interferometry using trapped ions. The ion trap based interferometer encloses a large area in a compact apparatus through repeated round-trips in a Sagnac geometry. We show how a uniform magnetic field can be used to close the interferometer over a large dynamic range in rotation speed and measurement bandwidth without contrast loss. Since this technique does not require the ions to be confined in the Lamb-Dicke regime, Doppler laser cooling should be sufficient to reach a sensitivity of { S }=1.4× {10}-6 {{rad}} {{{s}}}-1 {{{H}}{{z}}}-1/2. , which features invited work from the best early-career researchers working within the scope of J. Phys. B. This project is part of the Journal of Physics series’ 50th anniversary celebrations in 2017. Wes Campbell was selected by the Editorial Board of J. Phys. B as an Emerging Leader.

  4. Surface microhardening by ion implantation

    International Nuclear Information System (INIS)

    Singh, Amarjit

    1986-01-01

    The paper discusses the process and the underlying mechanism of surface microhardening by implanting suitable energetic ions in materials like 4145 steel, 304 stainless steel, aluminium and its 2024-T351 alloy. It has been observed that boron and nitrogen implantation in materials like 4145 steel and 304 stainless steel can produce a significant increase in surface hardness. Moreover the increase can be further enhanced with suitable overlay coatings such as aluminium (Al), Titanium (Ti) and carbon (C). The surface hardening due to implantation is attributed to precipitation hardening or the formation of stable/metastable phase or both. The effect of lithium implantation in aluminium and its alloy on microhardness with increasing ion dose and ion beam energy is also discussed. (author)

  5. Inorganic ion composition in Tardigrada

    DEFF Research Database (Denmark)

    Halberg, Kenneth Agerlin; Larsen, Kristine Wulff; Jørgensen, Aslak

    2013-01-01

    composition and total osmotic concentration of five different species of tardigrades (Echiniscus testudo, Milnesium tardigradum, Richtersius coronifer, Macrobiotus cf. hufelandi and Halobiotus crispae) using high-performance liquid chromatography and nanoliter osmometry. Quantification of the ionic content....... Concentrations of most inorganic ions are largely identical between active and dehydrated groups of R. coronifer, suggesting that this tardigrade does not lose large quantities of inorganic ions during dehydration. The large osmotic and ionic gradients maintained by both limno-terrestrial and marine species...... are indicative of a powerful ion-retentive mechanism in Tardigrada. Moreover, our data indicate that cryptobiotic tardigrades contain a large fraction of unidentified organic osmolytes, the identification of which is expected to provide increased insight into the phenomenon of cryptobiosis....

  6. Results of heavy ion radiotherapy

    International Nuclear Information System (INIS)

    Castro, J.R.

    1994-04-01

    The potential of heavy ion therapy for clinical use in cancer therapy stems from the biological parameters of heavy charged particles, and their precise dose localization. Biologically, carbon, neon and other heavy ion beams (up to about silicon) are clinically useful in overcoming the radioresistance of hypoxic tumors, thus increasing biological effectiveness relative to low-LET x-ray or electron beams. Cells irradiated by heavy ions show less variation in cell-cycle related radiosensitivity and decreased repair of radiation injury. The physical parameters of these heavy charged particles allow precise delivery of high radiation doses to tumors while minimizing irradiation of normal tissues. Clinical use requires close interaction between radiation oncologists, medical physicists, accelerator physicists, engineers, computer scientists and radiation biologists

  7. Materials Science with Ion Beams

    CERN Document Server

    Bernas, Harry

    2010-01-01

    This book introduces materials scientists and designers, physicists and chemists to the properties of materials that can be modified by ion irradiation or implantation. These techniques can help design new materials or to test modified properties; novel applications already show that ion-beam techniques are complementary to others, yielding previously unattainable properties. Also, ion-beam interactions modify materials at the nanoscale, avoiding the often detrimental results of lithographic or chemical techniques. Here, the effects are related to better-known quasi-equilibrium thermodynamics, and the consequences to materials are discussed with concepts that are familiar to materials science. Examples addressed concern semiconductor physics, crystal and nanocluster growth, optics, magnetism, and applications to geology and biology.

  8. Hybrid Lithium-ion Capacitor / Lithium-ion Battery System for Extended Performance

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed task will involve the design of a hybrid power system with lithium-ion (li-ion) capacitors (LICs), li-ion batteries and solar cells. The challenge in...

  9. Surface engineering by ion implantation

    International Nuclear Information System (INIS)

    Nielsen, Bjarne Roger

    1995-01-01

    Awidespread commercial applica tion iof particle accelerators is for ion implantation. Accelerator beams are used for ion implantation into metals, alloying a thin surface layer with foreign atoms to concentrations impossible to achieve by thermal processes, making for dramatic improvements in hardness and in resistance to wear and corrosion. Traditional hardening processes require high temperatures causing deformation; ion implantation on the other hand is a ''cold process'', treating the finished product. The ionimplanted layer is integrated in the substrate, avoiding the risk of cracking and delamination from normal coating processes. Surface properties may be ''engineered'' independently of those of the bulk material; the process does not use environmentally hazardous materials such as chromium in the surface coating. The typical implantation dose required for the optimum surface properties of metals is around 2 x 10 17 ion/cm 2 , a hundred times the typical doses for semiconductor processing. When surface areas of more than a few square centimetres have to be treated, the implanter must therefore be able to produce high beam currents (5 to 10 mA) to obtain an acceptable treatment time. Ion species used include nitrogen, boron, carbon, titanium, chromium and tantalum, and beam energies range from 50 to 200 keV. Since most components are three dimensional, it must be possible to rotate and tilt them in the beam, and control beam position over a large area. Examples of industrial applications are: - surface treatment of prostheses (hip and knee joints) to reduce wear of the moving parts, using biocompatible materials; - ion implantation into high speed ball bearings to protect against the aqueous corrosion in jet engines (important for service helicopters on oil rigs); - hardening of metal forming and cutting tools; - reduction of corrosive wear of plastic moulding tools, which are expensive to produce

  10. On line pre-concentration for simultaneous determination of low molecular weight organic acids and inorganic anions in Amazonian river water samples employing ion chromatography with conductivity detection Pré-concentração em linha para a determinação simultânea de ácidos carboxílicos de baixo peso molecular e ânions inorgânicos em amostras de rios da Amazônia empregando cromatografia de íons com detecção por condutividade elétrica

    Directory of Open Access Journals (Sweden)

    Cristiane Azevedo Tumang

    2009-01-01

    Full Text Available An ion chromatography procedure, employing an IonPac AC15 concentrator column was used to investigate on line preconcentration for the simultaneous determination of inorganic anions and organic acids in river water. Twelve organic acids and nine inorganic anions were separated without any interference from other compounds and carry-over problems between samples. The injection loop was replaced by a Dionex AC15 concentrator column. The proposed procedure employed an auto-sampler that injected 1.5 ml of sample into a KOH mobile phase, generated by an Eluent Generator, at 1.5 mL min-1, which carried the sample to the chromatographic columns (one guard column, model AG-15, and one analytical column, model AS15, with 250 x 4mm i.d.. The gradient elution concentrations consisted of a 10.0 mmol l-1 KOH solution from 0 to 6.5 min, gradually increased to 45.0 mmol l-1 KOH at 21 min., and immediatelly returned and maintained at the initial concentrations until 24 min. of total run. The compounds were eluted and transported to an electro-conductivity detection cell that was attached to an electrochemical detector. The advantage of using concentrator column was the capability of performing routine simultaneous determinations for ions from 0.01 to 1.0 mg l-1 organic acids (acetate, propionic acid, formic acid, butyric acid, glycolic acid, pyruvate, tartaric acid, phthalic acid, methanesulfonic acid, valeric acid, maleic acid, oxalic acid, chlorate and citric acid and 0.01 to 5.0 mg l-1 inorganic anions (fluoride, chloride, nitrite, nitrate, bromide, sulfate and phosphate, without extensive sample pretreatment and with an analysis time of only 24 minutes.A metodologia analítica foi desenvolvida empregando coluna pré-concentradora AC15 em linha na cromatografia iônica na determinação simultânea de ânions orgânicos e inorgânicos, com uso de coluna de guarda AG15 e analítica AS15, 250 x 4 mm i.d. (Dionex Corp.. O gradiente de concentração do eluente

  11. Ion-responsive fluorescent compounds

    International Nuclear Information System (INIS)

    Bourson, Jean; Borrel, M.N.; Valeur, Bernard; CNRS URA 1103, Paris

    1992-01-01

    The complexation ability of coumarin 153 linked to monoaza-15-crown-5 was studied. On complexation by alkaline earth metal ion, both absorption and emission spectra undergo a marked red shift whereas the effects are weaker with alkali metal ions. Owing to the participation of the carbonyl group of the coumarin, the stability of the complexes is much higher than those observed with previously described fluoro-phores linked to monoaza-15-crown-5. The stability of the complexes remains high enough in acetonitrile-water mixtures for practical application to the determination of cation concentrations in aqueous samples to be possible. (author). 9 refs.; 3 figs.; 1 tab

  12. Ion exchange purification of scandium

    Science.gov (United States)

    Herchenroeder, L.A.; Burkholder, H.R.

    1990-10-23

    An improvement in purification of scandium through ion exchange chromatography is disclosed in which the oxidation potential of the eluting solution is altered by the addition of potassium chlorate or ammonium chloride so that removal of contaminants is encouraged. The temperature, pH and concentration of the eluent HEDTA are controlled in order to maintain the scandium in the column while minimizing dilution of the scandium band. Recovery of scandium is improved by pumping dilute scandium over the column prior to stripping the scandium and precipitation. This eliminates the HEDTA ion and other monovalent cations contaminating the scandium band. This method maximizes recovery of scandium while maintaining purity. 2 figs.

  13. Central collisions of heavy ions

    International Nuclear Information System (INIS)

    Fung, Sun-yiu.

    1991-10-01

    This report describes the activities of the Heavy Ion Physics Group at the University of California, Riverside from October 1, 1990 to September 30, 1991. During this period, our program focuses on particle production at AGS energies, and correlation studies at the Bevalac in nucleus central collisions. We participated in the preparation of letters of intent for two RHIC experiments -- the OASIS proposal and the Di-Muon proposal -- and worked on two RHIC R ampersand D efforts -- a silicon strip detector project and a muon-identifier project. A small fraction of time was also devoted to physics programs outside the realm of heavy ion reactions by several individuals

  14. Metrology of cesium ion thrusters

    International Nuclear Information System (INIS)

    Benoist, Roger; Labbe, Jean; Le Grives, Emile

    1974-01-01

    The various controls necessary to characterize cesium ion thrusters are presented. The following metrological process was developed by the ONERA: control of the thermal equilibrium and regulation of the temperature of the ionizer and of the cesium supply device, control of the ion current emission characterized both globally and locally, control of the ionization yield by the determination of the number of neutral cesium atoms by means of an appropriate detector and analysis of the structure of the beam by mapping the ionic current density. This characterization is completed by the results of cyclic regime tests runs reproducing the working conditions in satellites [fr

  15. Relativistic heavy ion facilities: worldwide

    International Nuclear Information System (INIS)

    Schroeder, L.S.

    1986-05-01

    A review of relativistic heavy ion facilities which exist, are in a construction phase, or are on the drawing boards as proposals is presented. These facilities span the energy range from fixed target machines in the 1 to 2 GeV/nucleon regime, up to heavy ion colliders of 100 GeV/nucleon on 100 GeV/nucleon. In addition to specifying the general features of such machines, an outline of the central physics themes to be carried out at these facilities is given, along with a sampling of the detectors which will be used to extract the physics. 22 refs., 17 figs., 3 tabs

  16. Ion guiding in alumina capillaries

    DEFF Research Database (Denmark)

    Juhász, Z.; Sulik, B.; Biri, S.

    2009-01-01

    focus our attention to the measurements with the MCP array. The alumina capillaries were prepared by electro-chemical oxidation of aluminium foils. For the present experiments guiding of 3-6 keV Ne ions has been studied in two samples with capillary diameter of about 140 nm and 260 nm and with capillary...... length of about 15 μm. At these energies, the ions have been efficiently guided by the capillaries up to few degrees tilt angle. In this work, we compare the results obtained by the energy dispersive spectrometer to those studied by the MCP array....

  17. High energy heavy ion collisions: Lessons from relativistic heavy ion ...

    Indian Academy of Sciences (India)

    crease in √s at RHIC brings us to a new regime of high energy heavy-ion collisions, ... Another scenario comes from the picture of particle production .... nuclear media. To study the effect on spectra, ratio between spectra from pA or AA with spectra from pp are taken. Spectra from pp are scaled for nuclear thickness.

  18. Fast ion-atom and ion-molecule collisions

    CERN Document Server

    2013-01-01

    The principal goal of this book is to provide state-of-the art coverage of the non-relativistic three- and four-body theories at intermediate and high energy ion-atom and ion-molecule collisions. The focus is on the most frequently studied processes: electron capture, ionization, transfer excitation and transfer ionization. The content is suitable both for graduate students and experienced researchers. For these collisions, the literature has seen enormous renewal of activity in the development and applications of quantum-mechanical theories. This subject is of relevance in several branches of science and technology, like accelerator-based physics, the search for new sources of energy and high temperature fusion of light ions. Other important applications are in life sciences via medicine, where high-energy ion beams are used in radiotherapy for which a number of storage ring accelerators are in full operation, under construction or planned to be built worldwide. Therefore, it is necessary to review this fiel...

  19. Ion Motion Stability in Asymmetric Surface Electrode Ion Traps

    Science.gov (United States)

    Shaikh, Fayaz; Ozakin, Arkadas

    2010-03-01

    Many recently developed designs of the surface electrode ion traps for quantum information processing have asymmetry built into their geometries. The asymmetry helps rotate the trap axes to angles with respect to electrode surface that facilitate laser cooling of ions but introduces a relative angle between the RF and DC fields and invalidates the classical stability analysis of the symmetric case for which the equations of motion are decoupled. For asymmetric case the classical motion of a single ion is given by a coupled, multi-dimensional version of Mathieu's equation. In this poster we discuss the stability diagram of asymmetric surface traps by performing an approximate multiple scale perturbation analysis of the coupled Mathieu equations, and validate the results with numerical simulations. After obtaining the stability diagram for the linear fields, we simulate the motion of an ion in a given asymmetric surface trap, utilizing a method-of-moments calculation of the electrode fields. We obtain the stability diagram and compare it with the ideal case to find the region of validity. Finally, we compare the results of our stability analysis to experiments conducted on a microfabricated asymmetric surface trap.

  20. Ion-Beam-Excited, Electrostatic, Ion Cyclotron Instability

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1977-01-01

    The stability limits of the ion‐beam‐excited, electrostatic, ion cyclotron instability were investigated in a Q‐machine plasma where the electrons could be heated by microwaves. In agreement with theory, the beam energy necessary for excitation decreased with increasing electron temperature....

  1. Ion-Beam-Excited Electrostatic Ion Cyclotron Instability

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1977-01-01

    The stability limits of the ion‐beam‐excited, electrostatic, ion cyclotron instability were investigated in a Q‐machine plasma where the electrons could be heated by microwaves. In agreement with theory, the beam energy necessary for excitation decreased with increasing electron temperature....

  2. ECR ion source based low energy ion beam facility

    Indian Academy of Sciences (India)

    The extraction of the positive ions from the plasma is done by polarizing the source at a positive potential with respect to ground and pulling ... electrostatic quadrupoles, Faraday cups etc. are controlled via the serial ports. Field point modules are used for AD and DA conversions. The software is written in LabView for easy.

  3. Interstellar processes: Ortho/para conversion, radiative association, and dissociative recombination

    Directory of Open Access Journals (Sweden)

    Herbst Eric

    2015-01-01

    Full Text Available The study of the ortho-to-para ratio of assorted gas-phase interstellar molecules such as H2, H2O, NH3, and H2O+ has gained interest in recent years, based partially on new spectral observations of light hydrides by the Herschel Space Observatory. Although these ratios can yield valuable information about the thermal history of the interstellar cloud where the molecules are found, an understanding of how the ratios are determined involves a number of often poorly studied processes, which can include both gas-phase and grain-surface reactions. In this article, we consider the processes that determine the ortho-to-para ratio of the molecular ion H2O+ in diffuse interstellar clouds and attempt to reproduce an unusual observed ratio for this ion. In addition to the study of ortho-to-para ratios, we look carefully at current uncertainties in the gas-phase formation of large neutral molecules in cold dense interstellar clouds via ion-neutral radiative association and dissociative recombination, among other processes.

  4. Dramatizar: levantarse para jugar, sentarse para escuchar un cuento

    OpenAIRE

    Gorria Serrano, Guillermo

    2015-01-01

    En el presente trabajo abordaremos la educación infantil, de una manera ambiciosa a través del movimiento y de la dramatización. Lo que proponemos es una educación basada en la naturaleza del niño como animal y apoyada con palabras de Rudolf Steiner, basándonos en cómo juegan todos los animales al ser educados, en cómo se imitan los unos a otros, entre mayores y pequeños. Es la base para un modelo pedagógico basado en el juego, el movimiento y la dramatización, para que los niños dejen un bue...

  5. A fast beam-ion instability

    Energy Technology Data Exchange (ETDEWEB)

    Stupakov, G.V. [Stanford Linear Accelerator Center, Menlo Park, CA (United States)

    1996-08-01

    The ionization of residual gas by an electron beam in an accelerator generates ions that can resonantly couple to the beam through a wave propagating in the beam-ion system. Results of the study of a beam-ion instability are presented for a multi-bunch train taking into account the decoherence of ion oscillations due to the ion frequency spread and spatial variation of the ion frequency. It is shown that the combination of both effects can substantially reduce the growth rate of the instability. (author)

  6. Microfabricated linear Paul-Straubel ion trap

    Science.gov (United States)

    Mangan, Michael A [Albuquerque, NM; Blain, Matthew G [Albuquerque, NM; Tigges, Chris P [Albuquerque, NM; Linker, Kevin L [Albuquerque, NM

    2011-04-19

    An array of microfabricated linear Paul-Straubel ion traps can be used for mass spectrometric applications. Each ion trap comprises two parallel inner RF electrodes and two parallel outer DC control electrodes symmetric about a central trap axis and suspended over an opening in a substrate. Neighboring ion traps in the array can share a common outer DC control electrode. The ions confined transversely by an RF quadrupole electric field potential well on the ion trap axis. The array can trap a wide array of ions.

  7. Ion mobility spectrometer with virtual aperture grid

    Science.gov (United States)

    Pfeifer, Kent B.; Rumpf, Arthur N.

    2010-11-23

    An ion mobility spectrometer does not require a physical aperture grid to prevent premature ion detector response. The last electrodes adjacent to the ion collector (typically the last four or five) have an electrode pitch that is less than the width of the ion swarm and each of the adjacent electrodes is connected to a source of free charge, thereby providing a virtual aperture grid at the end of the drift region that shields the ion collector from the mirror current of the approaching ion swarm. The virtual aperture grid is less complex in assembly and function and is less sensitive to vibrations than the physical aperture grid.

  8. MODELO PARA ESTABLECER SANCIONES PECUNIARIAS PARA DELITOS AMBIENTALES

    Directory of Open Access Journals (Sweden)

    LUIS DIEGO VÉLEZ GÓMEZ

    2012-01-01

    Full Text Available Este artículo pretende exponer el modelo básico que sustenta el desarrollo de multas óptimas; en él se muestra la forma de desincentivar los intereses del violador de la normatividad ambiental, e igualmente el método para alcanzar efectos compensatorios sobre los daños cometidos al medio ambiente. El desarrollo del tema sobre sanciones pecuniarias (multas y penalidades (encarcelamiento toma la relación contractual entre el agente (la empresa y el principal (La entidad reguladora para, a través de esta relación, entrar en la determinación de un diseño eficaz de sanciones. Se utilizara el modelo de agente-principal para examinar los efectos de las sanciones corporativas e individuales sobre los incentivos de cumplimiento en el contexto ambiental; además se emplearán los conceptos de bienes públicos, bienes comunes y externalidades como categorías de análisis que permiten la identificación y valoración de daños ambientales.

  9. MODELO PARA LA CREACIÓN DEL CONOCIMIENTO PARA PYMES

    Directory of Open Access Journals (Sweden)

    Marino Valencia Rodríguez

    2009-01-01

    Full Text Available La creciente importancia del conocimiento, como nuevo factor de producción, hace que la creación y transferencia se convierta en una de las principales prioridades de las organizaciones. El presente artículo describe tanto los fundamentos de la teoría de los recursos y capacidades de la empresa como el enfoque de la gestión del conocimiento, con sus procesos de generación y transferencia del conocimiento. Estos sirven de guía básica teórica para alcanzar el siguiente objetivo: Diseñar un modelo de generación y transferencia de conocimiento para los procesos de dirección, gestión humana y del conocimiento para PyMES, con el fin de que éstas alcancen mayores niveles de competitividad. El modelo se diseña, a partir del direccionamiento estratégico de la organización. Está conformado por tres etapas, articuladas con elementos y actividades. Las acciones se enfocan en dos factores clave de éxito: la cultura organizacional y la formación. La utilización del modelo permitirá a las PyMES optimizar los recursos y capacidades disponibles, lo cual se refleja en el desempeño del trabajador y en el fortalecimiento de la cultura organizacional.

  10. Correlated ion stopping in plasmas

    International Nuclear Information System (INIS)

    Zwicknagel, G.; Deutsch, C.

    1997-01-01

    The basic features of correlated ion stopping in plasmas are demonstrated by employing two opposite extremes of cluster structures, a statistical model with a spatial ion distribution of Gaussian shape and the highly regular configuration of N-ion chains and cubic boxes. In the case of the ion chains the resonant character of correlated stopping due to the interference of the excited wake fields is discussed in detail. The general behavior of correlation effects is summarized and its dependence on the ratio of cluster size and interion spacing to the screening length in the plasma, as well as the ratio of the cluster velocity to the mean electron velocity in the target, is stressed out. The validity and applicability of the dielectric response formalism used for describing correlated stopping is critically reviewed. A scheme is presented to extend the linear formalism to weak nonlinear situations that occur, in particular, for small highly charged clusters at moderate or low velocities. For the Gaussian cluster a fit formula is given, which allows a fast and accurate calculation of the enhancement of stopping due to correlation effects and applies for all degrees of degeneracy of the electrons and arbitrary cluster velocities. copyright 1997 The American Physical Society

  11. Heavy ion seeks phase transition

    International Nuclear Information System (INIS)

    Ducomet, B.

    1987-11-01

    The emergence of the phase transition language in the context of heavy ion collisions at the so called ''GANIL energies'' (typically 10 - 100 MeV/u) has led us to make more precise some current definitions adopted in statistical mechanics, and used in a much less clear way in the nuclear physics context [fr

  12. Quantum computing with trapped ions

    International Nuclear Information System (INIS)

    Haeffner, H.; Roos, C.F.; Blatt, R.

    2008-01-01

    Quantum computers hold the promise of solving certain computational tasks much more efficiently than classical computers. We review recent experimental advances towards a quantum computer with trapped ions. In particular, various implementations of qubits, quantum gates and some key experiments are discussed. Furthermore, we review some implementations of quantum algorithms such as a deterministic teleportation of quantum information and an error correction scheme

  13. Summary of heavy ion theory

    International Nuclear Information System (INIS)

    Gavin, S.

    1994-09-01

    Can we study hot QCD using nuclear collisions? Can we learn about metallic hydrogen from the impact of comet Shoemaker-Levy 9 on Jupiter? The answer to both questions may surprise you exclamation point I summarize progress in relativistic heavy ion theory reported at DPF '94 in the parallel sessions

  14. Future relativistic heavy ion experiments

    International Nuclear Information System (INIS)

    Pugh, H.G.

    1980-12-01

    Equations of state for nuclear matter and ongoing experimental studies are discussed. Relativistic heavy ion physics is the only opportunity to study in the laboratory the properties of extended multiquark systems under conditions such that quarks might run together into new arrangements previously unobserved. Several lines of further study are mentioned

  15. Ion bombardment modification of surfaces

    International Nuclear Information System (INIS)

    Auciello, O.

    1984-01-01

    Ion bombardment-induced modification of surfaces may be considered one of the significant scientific and technological developments of the last two decades. The understanding acquired concerning the underlying mechanisms of several phenomena occurring during ion-surface interactions has led to applications within different modern technologies. These include microelectronics, surface acoustical and optical technologies, solar energy conversion, thin film technology, ion implantation metallurgy, nuclear track technology, thermonuclear fusion, vacuum technology, cold welding technology, biomedicine (implantology). It has become clear that information on many relevant advances, regarding ion bombardment modification of surfaces is dispersed among journals involving fields sometimes not clearly related. This may result, in some cases, in a loss of the type of interdisciplinary exchange of ideas, which has proved to be so fruitful for the advancement of science and technology. This book has been planned in an attempt to collect at least some of today's relevant information about the experimental and theoretical knowledge related to surface modification and its application to technology. (Auth.)

  16. Ion exchange in analytical chemistry

    National Research Council Canada - National Science Library

    Rieman, William; Walton, Harold F

    1970-01-01

    ... to the analyst who wishes to calculate from the data of a few elutions the concentration and pH of eluent that will give the most efficient separation of a given mixture. This book will prove to be of value to analytical chemists, especially those intersted in separations, and physical chemists interested in ion exchange.

  17. Topics in heavy ion reactions

    International Nuclear Information System (INIS)

    Feshbach, H.

    1980-01-01

    Methods are discussed which, by straightforward extensions of currently available concepts and procedures, can be used for the description of reactions induced by heavy ions. The first section describes a nuclear Weiszaecker-Williams method for peripheral collisions of nuclei which is here extended to pion production in peripheral collisions. The second section emphasizes the relationship between the collision of an energetic proton and that of an energetic heavy ion with a nucleus. The comparatively remarkable behavior of the observed energy dependence of the angular distribution and average energy of the fragments produced in proton collision is described and a qualitative explanation offered. The third section is concerned with the'pre-equilibrium' reactions as well as the multi-step direct reactions which are known to play an important role in heavy ion collisions. A statistical theory of multi-step direct and multi-step compound reactions providing explicit expressions for the energy and angular distributions is formulated. A diffusion equation in momentum space is obtained as an approximation to these formulas. The extension of these results to heavy ion reactions in which phenomena involving deformation, mass and charge transfer and multi-particle final states are important, is made. (author)

  18. Ion beams make new blood

    International Nuclear Information System (INIS)

    Larousserie, D.

    2006-01-01

    In Russia a cyclotron has been designed and is now operating to make holes in plastic membranes: the impact of the ions produce tiny holes whose diameter is less than half a micrometer. These membranes are used in the fabrication of blood filters that are needed to separate blood corpuscles from plasma for instance. (A.C.)

  19. Ion-induced nuclear radiotherapy

    Science.gov (United States)

    Horn, K.M.; Doyle, B.L.

    1996-08-20

    Ion-induced Nuclear Radiotherapy (INRT) is a technique for conducting radiosurgery and radiotherapy with a very high degree of control over the spatial extent of the irradiated volume and the delivered dose. Based upon the concept that low energy, ion induced atomic and nuclear reactions can be used to produce highly energetic reaction products at the site of a tumor, the INRT technique is implemented through the use of a conduit-needle or tube which conducts a low energy ion beam to a position above or within the intended treatment area. At the end of the conduit-needle or tube is a specially fabricated target which, only when struck by the ion beam, acts as a source of energetic radiation products. The inherent limitations in the energy, and therefore range, of the resulting reaction products limits the spatial extent of irradiation to a pre-defined volume about the point of reaction. Furthermore, since no damage is done to tissue outside this irradiated volume, the delivered dose may be made arbitrarily large. INRT may be used both as a point-source of radiation at the site of a small tumor, or as a topical bath of radiation to broad areas of diseased tissue. 25 figs.

  20. Production of negative helium ions

    International Nuclear Information System (INIS)

    Toledo, A.S. de; Sala, O.

    1977-01-01

    A negative helium ion source using potassium charge exchange vapor has been developed to be used as an injector for the Pelletron accelerator. 3 He and α beam currents of up to 2μA have been extracted with 75% particle transmission through the machine [pt