WorldWideScience

Sample records for tld-100 dosemeters eficiencias

  1. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E.; Avila, O.; Rodriguez V, M. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico); Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E. [IFUNAM, 04500 Mexico D.F. (Mexico); Gamboa De Buen, I. [ICN-UNAM, 04500 Mexico D.F. (Mexico)

    2007-07-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  2. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation; Eficiencias termoluminiscentes relativas de TLD-100 para iones de nitrogeno respecto de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Concha S, K. [UNAM, Facultad de Ciencias, 04510 Mexico D.F. (Mexico); Avila, O. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Gamboa de Buen, I. [ICN-UNAM, 04510 Mexico D.F. (Mexico); Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E. [IFUNAM, 04510 Mexico D.F. (Mexico)

    2004-07-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of {sup 60} Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E{sub 1} energy (4.8 MeV) and E{sub 2} (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  3. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.; Avila, O.; Rodriguez V, M.; Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E.; Gamboa De Buen, I.

    2007-01-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  4. Thermoluminescent response of dosemeters TLD-100 exposed to distinct baker protocols, irradiation and reading

    International Nuclear Information System (INIS)

    Estrada E, D.

    2002-01-01

    The interest that motivated the realization of this work is the opposing discrepancy among the values of the efficiency thermoluminescent of heavy charged particles (PCP) regarding gamma radiation (η PCP , γ) reported in different works and gathered recently for Horowitz (Ho 01). The measures of relative thermoluminescent efficiency have importance in relation to the dosimetry associated to medical therapy with heavy charged particle. The measurement of η PCP , γ depends of multiple experimental factors. To understand this dependence it was quantified the effect of using different procedures experimental in the estimate of the relative thermoluminescent efficiency of dosemeters TLD-100 (LiF: Ti; Mg) for protons of 3 MeV regarding gamma rays of 60 Co (η PCP , γ), varying the lot, the presentation, the one baked and the team reader. When was used the same global procedure values they were obtained for (η PCP , γ) inside the interval [0.30, 0.58] for the peak 5 and [0.35, 0.76] for the total thermoluminescent signal (Tl). At the use different equipment, baked and lot are obtained maximum differences of 30%, 12% and 6% respectively in the values of (η PCP , γ) for the peak 5, and 25%, 28% and 7% for the total Tl signal. The changes more significant of 36% and 44% for peak 5 and total signal respectively are obtained when changing the presentation of the dosemeter. As a complementary investigation it was studied the distribution of the Tl signal of each peak in the deconvolution of the curve of brightness with regard to the total signal in exposed dosemeters to high fluence of protons (1x10 10 p/cm 2 ) varying the experimental protocol. It was found that the distribution of the Tl signal has a difference of the order of 5% when changing the used reading team. It was observed that the contribution of the peak 5 regarding the total signal are preserved when changing baked and that it results to be 8% greater for the presentation in dosemeters of 1 x 1 x 1 mm 3

  5. Dosimetric characteristics of a TLD dosemeter with extremities

    International Nuclear Information System (INIS)

    Molina P, D.; Diaz B, E.; Lien V, R.

    1999-01-01

    It was designed a TLD dosemeter for the monitoring of the extremities. This one consists in a metallic ring with a circular orifice where is arranged a T L detector of LiF: Mg,Ti (Model JR1152C) 5 x 5 x 0.8 mm 3 covered by a polyethylene fine layer. In this work were studied the dosimetric properties of the dosemeter for its application in the dosimetry of extremities for photonic radiation. the results obtained allow conclude that the designed dosemeter can be used for the extremities monitoring. (Author)

  6. Thermoluminescent response of dosemeters TLD-100 exposed to distinct baker protocols, irradiation and reading; Respuesta termoluminiscente de dosimetros TLD-100 sujetos a distintos protocolos de horneado, irradiacion y lectura

    Energy Technology Data Exchange (ETDEWEB)

    Estrada E, D

    2002-07-01

    The interest that motivated the realization of this work is the opposing discrepancy among the values of the efficiency thermoluminescent of heavy charged particles (PCP) regarding gamma radiation ({eta}{sub PCP}, {gamma}) reported in different works and gathered recently for Horowitz (Ho 01). The measures of relative thermoluminescent efficiency have importance in relation to the dosimetry associated to medical therapy with heavy charged particle. The measurement of {eta}{sub PCP}, {gamma} depends of multiple experimental factors. To understand this dependence it was quantified the effect of using different procedures experimental in the estimate of the relative thermoluminescent efficiency of dosemeters TLD-100 (LiF: Ti; Mg) for protons of 3 MeV regarding gamma rays of {sup 60}Co ({eta}{sub PCP}, {gamma}), varying the lot, the presentation, the one baked and the team reader. When was used the same global procedure values they were obtained for ({eta}{sub PCP}, {gamma}) inside the interval [0.30, 0.58] for the peak 5 and [0.35, 0.76] for the total thermoluminescent signal (Tl). At the use different equipment, baked and lot are obtained maximum differences of 30%, 12% and 6% respectively in the values of ({eta}{sub PCP}, {gamma}) for the peak 5, and 25%, 28% and 7% for the total Tl signal. The changes more significant of 36% and 44% for peak 5 and total signal respectively are obtained when changing the presentation of the dosemeter. As a complementary investigation it was studied the distribution of the Tl signal of each peak in the deconvolution of the curve of brightness with regard to the total signal in exposed dosemeters to high fluence of protons (1x10{sup 10} p/cm{sup 2}) varying the experimental protocol. It was found that the distribution of the Tl signal has a difference of the order of 5% when changing the used reading team. It was observed that the contribution of the peak 5 regarding the total signal are preserved when changing baked and that it

  7. Obtention of thermoluminescent efficiencies by means of irradiation of TLD-100 dosemeters with proton beams helium and carbon

    International Nuclear Information System (INIS)

    Avila, O.; Rodriguez V, M.; Aviles, P.; Gamboa de Buen, I.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E.

    2002-01-01

    In this work, the advances of a serial of measurements of relative efficiency thermoluminescent of heavy charged particles (PCP) with respect to gamma radiation for TLD-100, dosemeters of LiF: Mg,Ti manufactured by the Harshaw-Bicron company are reported. The PCP are essentials in the implementation of dosimetry associated with medical applications. The measurements before gamma radiation were carrying out using the Vickrad irradiator of the National Institute of Nuclear Research at dose of 1.663 Gy. The measures which are reported about protons, helium and carbon were realized using the Pelletron accelerator of the Physics Institute of the UNAM. (Author)

  8. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E. [UNAM, Facultad de Ciencias, 04510 Mexico D.F. (Mexico)

    2007-07-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  9. Dosimetric characteristics of a TLD dosemeter with extremities; Caracteristicas dosimetricas de un dosimetro TLD de extremidades

    Energy Technology Data Exchange (ETDEWEB)

    Molina P, D.; Diaz B, E.; Lien V, R. [Centro de Proteccion e Higiene de las Radiaciones, CPHR, Apdo.Postal 6195, Habana 6, CP 10600, Ciudad Habana (Cuba)

    1999-07-01

    It was designed a TLD dosemeter for the monitoring of the extremities. This one consists in a metallic ring with a circular orifice where is arranged a T L detector of LiF: Mg,Ti (Model JR1152C) 5 x 5 x 0.8 mm{sup 3} covered by a polyethylene fine layer. In this work were studied the dosimetric properties of the dosemeter for its application in the dosimetry of extremities for photonic radiation. the results obtained allow conclude that the designed dosemeter can be used for the extremities monitoring. (Author)

  10. Effective dose assessment in the maxillofacial region using thermoluminescent (TLD) and metal oxide semiconductor field-effect transistor (MOSFET) dosemeters: a comparative study

    NARCIS (Netherlands)

    Koivisto, J.; Schulze, D.; Wolff, J.E.H.; Rottke, D.

    2014-01-01

    Objectives: The objective of this study was to compare the performance of metal oxide semiconductor field-effect transistor (MOSFET) technology dosemeters with thermoluminescent dosemeters (TLDs) (TLD 100; Thermo Fisher Scientific, Waltham, MA) in the maxillofacial area. Methods: Organ and effective

  11. Effective dose assessment in the maxillofacial region using thermoluminescent (TLD) and metal oxide semiconductor field-effect transistor (MOSFET) dosemeters: a comparative study.

    Science.gov (United States)

    Koivisto, J; Schulze, D; Wolff, J; Rottke, D

    2014-01-01

    The objective of this study was to compare the performance of metal oxide semiconductor field-effect transistor (MOSFET) technology dosemeters with thermoluminescent dosemeters (TLDs) (TLD 100; Thermo Fisher Scientific, Waltham, MA) in the maxillofacial area. Organ and effective dose measurements were performed using 40 TLD and 20 MOSFET dosemeters that were alternately placed in 20 different locations in 1 anthropomorphic RANDO(®) head phantom (the Phantom Laboratory, Salem, NY). The phantom was exposed to four different CBCT default maxillofacial protocols using small (4 × 5 cm) to full face (20 × 17 cm) fields of view (FOVs). The TLD effective doses ranged between 7.0 and 158.0 µSv and the MOSFET doses between 6.1 and 175.0 µSv. The MOSFET and TLD effective doses acquired using four different (FOV) protocols were as follows: face maxillofacial (FOV 20 × 17 cm) (MOSFET, 83.4 µSv; TLD, 87.6 µSv; -5%); teeth, upper jaw (FOV, 8.5 × 5.0 cm) (MOSFET, 6.1 µSv; TLD, 7.0 µSv; -14%); tooth, mandible and left molar (FOV, 4 × 5 cm) (MOSFET, 10.3 µSv; TLD, 12.3 µSv; -16%) and teeth, both jaws (FOV, 10 × 10 cm) (MOSFET, 175 µSv; TLD, 158 µSv; +11%). The largest variation in organ and effective dose was recorded in the small FOV protocols. Taking into account the uncertainties of both measurement methods and the results of the statistical analysis, the effective doses acquired using MOSFET dosemeters were found to be in good agreement with those obtained using TLD dosemeters. The MOSFET dosemeters constitute a feasible alternative for TLDs for the effective dose assessment of CBCT devices in the maxillofacial region.

  12. A new TLD system for space research

    International Nuclear Information System (INIS)

    Feher, I.; Deme, S.; Szabo, B.; Vagvoelgyi, J.; Szabo, P.P.; Csoeke, A.; Ranky, M.; Akatov, Yu.A.

    1980-06-01

    A small, portable, vibration and shock resistant thermoluminescent dosemeter (TLD) system was developed to measure the cosmic radiation dose on board of a spacecraft. The TLD system consists of a special bulb dosemeter and a TLD reader. The measuring dose range of the TLD system is from 10 μGy up to 100 mGy. The TLD reader can operate on a battery; its electrical power consumption is about 5 W, its volume is about 1 dm 3 and its mass is about 1 kg. Details are given of the construction and technical parameters of the dosemeter and reader. (author)

  13. Experimental calibration and determination of the relative response for Lif: Mg, Ti(TLD-100) dosemeters at 60Co gamma and 60 kVp X-ray energies

    International Nuclear Information System (INIS)

    Marco, M.L.; Gonzalez, L.; Delgado, V.; Vano, E.; Moran, P.

    1985-01-01

    The thermoluminescence efficiency of LiF: Mg, Ti (TLD-100) dosemeters has been determined for photon beams from 60 Co gamma rays and 60 kVp X-rays. It has been proven that light yield varies as a function of the photon energy. An experiment was performed using an X-ray beam whose spectrum has been determined by an X-ray fluorescence method. This enabled a direct calculation of the absorbed doses in the T1 material for the different operation conditions. These values and the experimental ones from measuring T1 intensities have been used to obtain the efficiency for energy X-ray spectrum. From the above values, the dosemeter T1 response, relative to 60 Co, has been evaluated. (author)

  14. Proton/gamma relative thermoluminescence efficiencies of LiF:Mg,Cu,P+PTFE prepared at ININ and TLD-100H

    International Nuclear Information System (INIS)

    Avila, O.; Gonzalez, P.; Murillo, G.

    2009-10-01

    Properties of LiF:Mg,Cu,P+PTFE dosemeters developed at ININ have been investigated in order to evaluate their performance compared to those of equivalent commercial dosemeters. In this work both LiF:Mg,Cu,P+PTFE and TLD-100H pellets were exposed to low fluence 3 MeV protons and to low dose gamma radiation to evaluate experimental proton/gamma efficiencies. Gamma irradiation was performed using the Vic krad irradiator at ININ at varying doses between 25 and 500 mGy. For proton irradiation the Tandem Van de Graaff accelerator at ININ was used. Dosemeters were placed on a holder inside a scattering chamber where protons impinge on a gold target and scatter in all directions. The holder allows for several angular positions so that dosemeters receive proton fluence between 10 6 and 10 1 0 p/cm 2 . Experimental efficiency values found for LiF:Mg,Cu,P+PTFE and TLD-100H were 0.18 +- 03 and 0.23 +- 0.03, respectively. These results allow to confirm the reliability of the dosemeters developed at ININ. (Author)

  15. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation

    International Nuclear Information System (INIS)

    Concha S, K.; Avila, O.; Gamboa de Buen, I.; Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E.

    2004-01-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of 60 Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E 1 energy (4.8 MeV) and E 2 (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  16. Self-shielding factors for TLD-600 and TLD-100 in an isotropic flux of thermal neutrons

    International Nuclear Information System (INIS)

    Horowitz, Y.S.; Dubi, A.; Ben Shahar, B.

    1976-01-01

    The applications of lithium fluoride thermoluminescent dosemeters in mixed n-γ environments, and the dependence of LiF-TL on linear energy transfer are both topics of current interest. Monte Carlo calculations have therefore been carried out to determine the thermal neutron absorption probability (and consequently the self-shielding factor) for an isotropic flux of neutrons impinging on different sized cylindrical samples of LiF TLD-100 and TLD-600. The calculations were performed for cylinders of radius up to 10 cm and heights of 0.1 to 1.5 cm. The Monte Carlo results were found to be significantly different from the analytic calculations for infinitely long cylinders, but, as expected, converged to the same value for (r/h) << 1. (U.K.)

  17. In-vivo dosimetry in radiotherapy: a comparison of the response of semiconductor and thermoluminescence (TLD700) dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Vynckier, S [Universite Catholique de Louvain, Brussels (Belgium). Cliniques Universitaires St. Luc; Greffe, J L; Loncol, T; Vanneste, F; Octave-Prignot, M; Denis, J M; De Patoul, N

    1995-12-01

    Semiconductor dosemeters and thermoluminescence dosemeters were calibrated in view of in-vivo dosimetry. Their response in a 8 MV photon beam and the respective correction factors for the treatment conditions were systematically studied. A total of 249 entrance and exit measurements with this dual detector combination were performed, mainly for treatments of the head and neck region. The resulting entrance and exit doses were compared with the expected doses at these positions, calculated on basis of the treatment and patient parameters. The results at the entrance showed a value of 1.010 (2.8% for the ratio of the measured to the calculated dose by diodes, 1.013) 4.9% for the ratio of the measured to the calculated dose by TLD and 1.003 (3.6% for the ratio of the measured dose by TLD to diodes. With respect the exit dose, the results were 0.998) 4.9%, 1.016 (7.7% and 1.019) 7.0% respectively after correction for the heterogeneity`s. Although the standard deviation for the TLD dosemeters is systematically larger than the standard deviation for the diodes, it is concluded that both dosemeters will yield similar results for-in-vivo dosimetry, if utilized under the same conditions.

  18. Dosimetric properties of the 'Pille' portable, wide dose range TLD reader

    International Nuclear Information System (INIS)

    Szabo, P.P.; Feher, I.; Deme, S.; Szabo, B.; Vagvoelgyi, J.

    1986-01-01

    The dosimetric properties of a portable TLD reader are described. The TLD system named 'Pille' or 'moth' consists of a lightweight battery-operated portable TLD reader and its CaSO 4 :Dy bulb dosemeters. The reproducibility of the TLD system at constant temperature was found to be better than + -2%, and the mean time between failures exceeded 5 years. The dose range of the system is wide, covering more than 6 orders of magnitude, from 5 μGy to 10 Gy. The energy dependence of the CaSO 4 :Dy bulb dosemeters is less than + - 20% above 100 keV in the energy compensation capsules. Without additional annealing, the bulb dosemeters can be re-used at least 100 times, which is an important aspect during in situ measurements. (author)

  19. Study of a method based on TLD detectors for in-phantom dosimetry in BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G. [Dept. of Physics of the Univ., Via Celoria 16, 20133 Milan (Italy); INFN, Natl. Inst. of Nuclear Physics, Via Celoria 16, 20133 Milan (Italy); Klamert, V. [Dept. of Nuclear Eng. of Polytechnic, CESNEF, Via Ponzio 34/3, 20133 Milan (Italy); Agosteo, S. [INFN, Natl. Inst. of Nuclear Physics, Via Celoria 16, 20133 Milan (Italy); Dept. of Nuclear Eng. of Polytechnic, CESNEF, Via Ponzio 34/3, 20133 Milan (Italy); Birattari, C.; Gay, S. [Dept. of Physics of the Univ., Via Celoria 16, 20133 Milan (Italy); INFN, Natl. Inst. of Nuclear Physics, Via Celoria 16, 20133 Milan (Italy); Rosi, G. [FIS-ION, ENEA, Casaccia, Via Anguillarese 301, 00060 Santa Maria di Galeria, Rome (Italy); Scolari, L. [Dept. of Physics of the Univ., Via Celoria 16, 20133 Milan (Italy); INFN, Natl. Inst. of Nuclear Physics, Via Celoria 16, 20133 Milan (Italy)

    2004-07-01

    A method has been developed, based on thermoluminescent dosemeters (TLD), aimed at measuring the absorbed dose in tissue-equivalent phantoms exposed to thermal or epithermal neutrons, separating the contributions of various secondary radiation generated by neutrons. The proposed method takes advantage of the very low sensitivity of CaF{sub 2}:Tm (TLD-300) to low energy neutrons and to the different responses to thermal neutrons of LiF:Mg,Ti dosemeters with different {sup 6}Li percentage (TLD-100, TLD-700, TLD-600). The comparison of the results with those obtained by means of gel dosemeters and activation foils has confirmed the reliability of the method. The experimental modalities allowing reliable results have been studied. The glow curves of TLD-300 after gamma or neutron irradiation have been compared; moreover, both internal irradiation effect and energy dependence have been investigated. For TLD-600, TLD-100 and TLD-700, the suitable fluence limits have been determined in order to avoid radiation damage and loss of linearity. (authors)

  20. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.

    2007-01-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  1. The right choice: extremity dosemeter for different radiation fields

    International Nuclear Information System (INIS)

    Brasik, N.; Stadtmann, H.; Kindl, P.

    2005-01-01

    Full text: Measurements of weakly penetrating radiation in personal dosimetry present problems in the design of suitable detectors and in the interpretation of their readings. For the measurement of the individual beta radiation dose, personal dosemeter for the fingers/tips are required. In general, the dosemeters currently used for personal monitoring of beta and low energy photon doses suffer from an energy threshold problem because the detector and/or the filter are too thick. TLDs of a standard thickness can seriously underestimate personal skin doses, especially in external fields of weakly penetrating radiation fields. LiF:Mg, Cu, P is a promising TL material which allows the production of thin detectors with sufficient sensitivity. Dosimetric properties of two different types of extremity dosemeters, designed to measure the personal dose equivalent Hp(0.07), have been compared: LiF:Mg, Ti (TLD100) and LiF:Mg, Cu, P (TLD700H). The first one consists of 100 mg.cm -2 LiF:Mg, Ti (TLD 100) chip and a 35mg. cm -2 cap, the other consists of a 7mg. cm -2 layer of LiF:Mg, Cu, P (TLD-700H) powder and a 5mg. cm -2 cap. The evaluation was done in two steps: performance tests (ISO-12794) and measurements in real workplaces. In the first step type test results for beta calibration were compared. In addition calibration for low energy photon radiation according to ISO 4037-3 was carried out. In the second step, simultaneous measurements with both types of dosemeters were performed at workplaces, where radiopharmaceuticals containing different radioisotopes are prepared and applied. Practices in these fields are characterized by handling of high activities at very small distances between source and skin. The results from the comparison of the two dosemeter types are presented and analyzed with respect to different radiation fields. Experiments showed a satisfactory sensitivity for the thinner dosemeter (TLD 700H) for detecting beta radiation at protection levels and a good

  2. Operational comparison of TLD albedo dosemeters and etched-track detectors in the PuO2-UO2 mixed oxide fuel fabrication facilities

    International Nuclear Information System (INIS)

    Tsujimura, N.; Takada, C.; Yoshida, T.; Momose, T.

    2005-01-01

    Full text: The authors carried out an operational study that compared the use of TLD albedo dosemeters with etched-track detector in plutonium environments of Japan Nuclear Cycle Development Institute, Tokai Works. A selected group of workers engaged in the fabrication process of MOX (PuO 2 -UO 2 mixed oxide) fuel wore both TLD albedo dosemeters and etched-track detectors over a period from 1991 to 1993. The TLD albedo dosemeter is the Panasonic model UD-809P and the etched-track detector is the NEUTRAK (polyallyl diglycol carbonate + 1mm-t polyethylene radiator) commercially available from Nagase-Landauer Ltd. Both dosemeters were issued and read monthly. It was found that the TL readings were generally proportional to the counted etch-pits, and thus the dose equivalent results obtained from TLD albedo dosemeter agreed with those from etched-track detector within a factor of 1.5. This result indicates that, in the workplaces of the MOX plants, the neutron spectrum remained almost constant in terms of time and space, and the appropriate range of field-specific correction with spectrum variations could be small in albedo dosimetry. In addition, the calibrations of both dosemeters in the workplaces and in a bare and moderated 252 Cf calibration field were performed for quantitative validation for the results from the operational comparison. In the former experiments, locations were selected that were representative of typical neutron measurements according to the prior neutron spectra measurements with the multi-sphere spectrometer. In the latter experiments, the workplace environments were simulated by using a 252 Cf source surrounded with cylindrical steel/PMMA moderators. From both experiments, the relationship between TL readings and counted etch-pits with neutron spectrum variation was determined. As expected, the relationship obtained from the simulated workplace field calibration reproduced that from the operational comparison. (author)

  3. TL response of LiF: Mg, Cu, P dosemeters in function of the photon energy

    International Nuclear Information System (INIS)

    Gonzalez, P.R.; Azorin, J.; Furetta, C.

    2005-01-01

    In this work the obtained results of studying the response of dosemeters of LiF: Mg, Cu, P + Ptfe, developed in the ININ, commercial dosemeters GR200A (LiF: Mg, Cu, P) of chinese manufacture and TLD-100 (LiF: Mg, Ti) US are presented, when irradiating them with X rays 16, 24, 34.5, 42, 100 and 145 keV of effective energy, with gamma rays of 662 keV ( 137 Cs) and 1252 keV ( 60 Co). The results are presented in function of the sensitivity that the dosemeters showed normalized to gamma radiation of 60 Co. It was appreciated that the dosemeters more equivalent to the tissue, they were those of LiF: Mg, Cu, P + Ptfe, while the less equivalent ones were the TLD-100. (Author)

  4. Robust determination of effective atomic numbers for electron interactions with TLD-100 and TLD-100H thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Taylor, M.L.

    2011-01-01

    Lithium fluoride thermoluminescent dosimeters (TLD) are the most commonly implemented for clinical dosimetry. The small physical magnitude of TLDs makes them attractive for applications such as small field measurement, in vivo dosimetry and measurement of out-of-field doses to critical structures. The most broadly used TLD is TLD-100 (LiF:Mg,Ti) and, for applications requiring higher sensitivity to low-doses, TLD-100H (LiF:Mg,Cu,P) is frequently employed. The radiological properties of these TLDs are therefore of significant interest. For the first time, in this study effective atomic numbers for radiative, collisional and total electron interaction processes are calculated for TLD-100 and TLD-100H dosimeters over the energy range 1 keV-100 MeV. This is undertaken using a robust, energy-dependent method of calculation rather than typical power-law approximations. The influence of dopant concentrations and unwanted impurities is also investigated. The two TLDs exhibit similar effective atomic numbers, ranging from approximately 5.77-6.51. Differences arising from the different dopants are most pronounced in low-energy radiative effects. The TLDs have atomic numbers approximately 1.48-2.06 times that of water. The effective atomic number of TLD-100H is consistently higher than that of TLD-100 over a broad energy range, due to the greater influence of the higher-Z dopants on the electron interaction cross sections. Typical variation in dopant concentration does not significantly influence the effective atomic number. The influence on TLD-100H is comparatively more pronounced than that on TLD-100. Contrariwise, unwanted hydroxide impurities influence TLD-100 more than TLD-100H. The effective atomic number is a key parameter that influences the radiological properties and energy response of TLDs. Although many properties of these TLDs have been studied rigorously, as yet there has been no investigation of their effective atomic numbers for electron interactions. The

  5. Characterization of the personal thermoluminescent dosemeter of LiF: Mg, Ti + Ptfe

    International Nuclear Information System (INIS)

    Azorin N, J.; Gutierrez C, A.; Gonzalez M, P.

    1991-01-01

    The objective of this work is to characterize the thermoluminescent dosemeters taken place in the laboratory in form of pellets of LiF: Mg, Ti + Ptfe like personal dosemeters, subjecting them to the operation tests proposed by the international standards and comparing them with the TLD-100, the Tl dosemeter more used at the moment for personal dosimetry

  6. Tl response of LiF: Mg, Cu, P + PTFE (Mexico) and GR200A (China) dosemeters

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.; Azorin N, J.; Furetta, C.

    2003-01-01

    TLD-100 was the commercial dosemeter more known since some decades ago. This dosemeter was considered for many research groups as the reference material for developing new Tl materials for ionizing radiation dosimetry. Actually it seems that TLD-100 is going to be replaced by the Chinese material GR200A, as reference material due that this material in addition to be considered as a tissue equivalent material, is 30 to 35 times more sensitive that TLD- 100. Results of the study of the Tl response of LiF: Mg, Cu, P + Ptfe developed at ININ-Mexico, comparing them with those of GR200A are presented. These results showed that the sensitivity (s = Tl intensity/weight x dose) to gamma radiation of the LiF: Mg, Cu, P + Ptfe dosimeters was 4.34 meanwhile that of the commercial dosemeter was 3.41. Detection threshold of the dosemeters studied was 2.22 and 0.52 μGy respectively Repeatability after 10 cycles Irradiation-reading-annealing was ±1.39% and ±1.86% respectively. Both types of dosemeters presented a linear response as a function of gamma radiation in the range from 0.02 mGy and 100 Gy. (Author)

  7. Measurement of TLD Albedo response on various calibration phantoms

    International Nuclear Information System (INIS)

    Momose, T.; Tsujimura, N.; Shinohara, K.; Ishiguro, H.; Nakamura, T.

    1996-01-01

    The International Commission on Radiation Units and Measurements (ICRU) has recommended that individual dosemeter should be calibrated on a suitable phantom and has pointed out that the calibration factor of a neutron dosemeter is strongly influenced by the the exact size and shape of the body and the phantom to which the dosemeter is attached. As the principle of an albedo type thermoluminescent personal dosemeter (albedo TLD) is essentially based on a detection of scattered and moderated neutron from a human body, the sensitivity of albedo TLD is strongly influenced by the incident neutron energy and the calibration phantom. (1) Therefore for albedo type thermoluminescent personal dosemeter (albedo TLD), the information of neutron albedo response on the calibration phantom is important for appropriate dose estimation. In order to investigate the effect of phantom type on the reading of the albedo TLD, measurement of the TLD energy response and angular response on some typical calibration phantoms was performed using dynamitron accelerator and 252 Cf neutron source. (author)

  8. Dosimertry characteristics and performance comparisons: Environmental radiophotoluminescent glass dosemeters versus thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Lee, J.H.; Lin, M.S.; Hsu, S.M.; Chen, I.J.; Chen, W.L.; Wang, C.F.

    2009-01-01

    This paper describes the dosimetry characteristic comparison of environmental radiophotoluminescent glass dosemeter (RPLGD) and thermoluminescent dosemeter (TLD) systems employed at the Institute of Nuclear Energy Research (INER, Taiwan). The luminescence centers of TLD disappeared by reading process, and repetition of measurement is impossible. RPLGDs can be repeatedly read and keep the luminescence centers for a long time. The RPLGD fading is about 1% within 30 days after being exposed to ionizing radiation. Environmental cumulative doses measured by a RPLGD and a TLD were compared at the same monitoring points of INER during two years. The sensitivity of TLD decreased with gradual loss due to fading at higher temperatures. The difference between results obtained by RPLGD and TLD is discussed mainly with respect to the dependence on the ambient temperature. In addition, this research also refers to the American National Standard Institute (ANSI) Draft Standard N13.29 (1996) to organize the environmental dosimetry performance tests of the INER's RPLGDs and the TLDs. The results mean that both kinds of dosemeters can meet the performance test criteria. An accreditation procedure for the institutes which provide the environmental dosimetry services in Taiwan was suggested based on the comparison results of these two dosimetry systems

  9. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative quantities ICRU, for external fields of beta radiation. Part II. I study of the angular response of personal dosemeters TLD-100 in secondary patron fields of beta radiation (90Sr / 90Y)

    International Nuclear Information System (INIS)

    Alvarez R, J.T.

    1994-01-01

    The objective of this work is to carry out one of the possible ones test type for personal dosemeters TLD, under the recomendations of the ICRU 39, ICRU 43 and the draft of the norm ISO 6980,(1992), with the purpose of verifying the capacity of these detectors to carry out the operative unit: H' (0.07;α). Since H' (O. 07;α) this defined one in an expanded field, one of these tests type consist on determining the angular response of these detectors. 20 personal dosemeters TLD-100 was used, (card marks: Harshaw, Model: G-1, with two glasses of TLD-100 absorbed in teflon; the portadosemeters has two windows, a free one and another with a filter of Pb of 171.0 mg cm -2 ); these dosemeters they were previously selected, [to see, S tudy of the Homogeneity of the response of Personal Dosemeters (Cards G-l, TLD-100) in Radiation of Countrysides of 60 Co , J.T. Alvarez R. Technician Report GSR/IT/0001/94].The irradiations to effectued in secondary countryside of radiation beta of 90 Sr/ 90 Y. The study was undertaken by means of an experimental design of blocks random that contemplate the following variables: intensity of the radiation source, (1850 MBq and 74 MBq); position of irradiation, (four positions); incidence of angle of the radiation (0, 15, 30, 45, 60 and 75 grades) and the absorbed dose in air, (0.005, 0.010, 0.020, 0.050 and 0.100 Gy). Then null hypothesis it was to suppose that there was not difference among the stockings of each treatment, to used the statistical of Duncan to carry out tests of stockings at a level of significance of 5%.These tests of stockings throw the following results in those variables of the experimental design: The irradiations carried out so much with the source pattern secondary of 90 Sr/ 90 Y of 1850 MBq and of 74 MBq, they are equivalent reason why they can be used indistinctly. The responses of each one of the glasses of the card are strongly anisotropic for each glass; four positions of irradiation is used: glass 1 (window of

  10. MCNP SIMULATION OF THE HP(10) ENERGY RESPONSE OF A BRAZILIAN TLD ALBEDO NEUTRON INDIVIDUAL DOSEMETER, FROM THERMAL TO 20 MeV.

    Science.gov (United States)

    Freitas, B M; Martins, M M; Pereira, W W; da Silva, A X; Mauricio, C L P

    2016-09-01

    The Brazilian Instituto de Radioproteção e Dosimetria (IRD) runs a neutron individual monitoring system with a home-made TLD albedo dosemeter. It has already been characterised and calibrated in some reference fields. However, the complete energy response of this dosemeter is not known, and the calibration factors for all monitored workplace neutron fields are difficult to be obtained experimentally. Therefore, to overcome such difficulties, Monte Carlo simulations have been used. This paper describes the simulation of the HP(10) neutron response of the IRD TLD albedo dosemeter using the MCNPX transport code, for energies from thermal to 20 MeV. The validation of the MCNPX modelling is done comparing the simulated results with the experimental measurements for ISO standard neutron fields of (241)Am-Be, (252)Cf, (241)Am-B and (252)Cf(D2O) and also for (241)Am-Be source moderated with paraffin and silicone. Bare (252)Cf are used for normalisation. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. A new extremity dosemeter for beta and gamma radiation

    International Nuclear Information System (INIS)

    Heinzelmann, M.; Pagenkamper, M.

    1988-01-01

    An extremity dosemeter developed at the Juelich Nuclear Research Centre is very well suited for the precise and energy-independent measurement of the skin dose generated by beta or gamma radiation. This is also confirmed by the results of this intercomparison programme. The dosemeter contains three TLDs of LiF in Teflon mounted behind a window of 0.9 mg/cm 2 . The great advantage of this dosemeter is three TLD's enabling statements about the radiation quality. However, the dosemeter has two disadvantages The dosemeter is complicated to manufacture. A very thin plastic foil of 0.9 mg/cm 2 must be attached to a support. This work is difficult and time-consuming and cannot be automated. The window in front of the TLD is not sturdy enough and is occasionally destroyed when the dosemeter is being worn. These two disadvantages prevent this extremity dosemeter from being used more frequently. For this reason, work was begun on developing a new extremity dosemeter without these two disadvantages. The great advantage of the previous dosemeter of obtaining statements about the type of radiation with the aid of readings from three TLD's was to be retained. The improved extremity dosemeter has a more sturdy and thicker window with a similar response as the previous dosemeter with a thinner window

  12. Towards an automated TLD system that meets international requirements

    International Nuclear Information System (INIS)

    Boetter-Jensen, L.; Vanamo, V.

    1988-01-01

    The new recently introduced fully automated TLD system developed by Alnor OY on the basis of the Riso prototype, is intended to meet draft IEC/ISO proposals and ANSI requirements. Part of the system is a personal dosemeter badge and an environmental dosemeter package following ICRU recommendations. The overall system consists of a software-controlled automated reader, a programable irradiator/calibrator, a computer, and dosemeters for environmental, whole body, extremity and clinical applications. The personal TLD badge that contains four TLD pellets is designed to agree with ICRU H p (10) and H s (0.07) quantities for determining dose equivalent. The badge can accommodate a large variety of the most commonly used solid TL dosemeter products. A special effort was put into the evaluation of skin dose by considering the use of graphite-mixed hot-sintered LiF pellets. The TLD system is described and results from a performance test that comprised measurements of photon energy response, angular dependence, and reproducibility are presented

  13. Thermoluminescent dosemeters (TLD) exposed to high fluxes of gamma radiation, thermal neutrons and protons

    International Nuclear Information System (INIS)

    Gambarini, G.; Martini, M.; Meinardi, F.; Raffaglio, C.; Salvadori, P.; Scacco, A.; Sichirollo, A.E.

    1996-01-01

    Thermoluminescent dosemeters (TLD), widely experimented and utilized in personal dosimetry, have some advantageous characteristics which induce one to employ them also in radiotherapy. The new radiotherapy techniques are aimed at selectively depositing a high dose in cancerous tissues. This goal is reached by utilising both conventional and other more recently proposed radiation, such as thermal neutrons and heavy charged particles. In these inhomogeneous radiation fields a reliable mapping of the spatial distribution of absorbed dose is desirable, and the utilized dosemeters have to give such a possibility without notably perturbing the radiation field with the materials of the dosemeters themselves. TLDs, for their small dimension and their tissue equivalence for most radiation, give good support in the mapping of radiation fields. After exposure to the high fluxes of therapeutic beams, some commercial TL dosemeters have shown a loss of reliability. An investigation has therefore be performed, both on commercial and on laboratory made phosphors, in order to investigate their behaviour in such radiation fields. In particular the thermal neutron and gamma ray mixed field of the thermal column of a nuclear reactor, of interest for Boron Neutron Capture Therapy (B.N.C.T.) and a proton beam, of interest for proton therapy, were considered. Here some results obtained with new TL phosphors exposed in such radiation fields are presented, after a short description of some radiation damage effect on commercial LiF TLDs exposed in the (n th ,γ) field of the thermal column of a reactor. (author)

  14. Comparative study of thermoluminescent properties of LiF: Mg, Cu, P, LiF: Mg, Ti and TLD-100 irradiated with X-rays

    International Nuclear Information System (INIS)

    Azorin, J.; Rivera, T.; Gonzalez, P.; Ortega, X.; Ginjaume, M.

    2000-01-01

    The thermoluminescent properties (Tl) of LiF: Mg, Cu, P, and LiF: Mg, Ti, were investigated both developed in Mexico and comparing them with the properties of TLD-100 when they are exposure to X-rays. The Tl curve of LiF: Mg, Cu, P exhibited two peaks at 200 and 300 Centigrade. Its response Tl in function of dose resulted linear in the interval of 0.5 Gy until 5 Gy and its sensitivity to X-ray was around 25 times greater that of the TLD-100. Also it was measured the Tl response of the three materials in function of photon energy. The results showed that LiF: Mg, Cu, P has potential to be used as X-ray dosemeter. (Author)

  15. Environmental radiation measurements using TLD in and around AERE, Dhaka

    International Nuclear Information System (INIS)

    Mollah, A.S.; Husain, S.R.; Rahman, M.M.

    1986-01-01

    The external background radiation level in and around the Atomic Energy Research Establishment (AERE) in Dhaka has been measured. The measurements were performed using lithium fluoride (LiF) thermoluminescence dosemeters (TLD-100) at 32 locations, all one metre above the ground. The annual average dose rate measured in the AERE environs was 1.74+-0.23 mGy.y -1 in air, based on analysis of thermoluminescence dosemeter data collected from 1982 to 1984. (author)

  16. Measurement of gamma radiation doses at the RA reactor by thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Prokic, M.

    1974-01-01

    This paper presents the procedures and gamma radiation doses measured at the exit from the horizontal experimental channel HK-5, vertical experimental channel VK-5 and in the thermal column of the RA reactor in Vinca. Measurement of gamma radiation dose in the mixed intense gamma and neutron radiation field was done by two types of thermoluminescent dosemeters, LiF (TLD-700) and CaF 2 (TLD-08). Gamma dose in the VK-5 was measured in the air and on the bottle filled with tissue-equivalent solution. Increase of the dose on the surface of the bottle was 2.3 compared to the gamma dose value in the air. Correction for the influence of neutrons having different energies was done by using the known sensitivity values of both TL dosemeter types for thermal, intermediate and fast neutrons. Results showed that the TLD-700 dosemeter contains 5 time more Li-6 isotopes (0.035%) than the declared value causing increased neutron sensitivity of this dosemeter. This paper includes numerical sensitivity data for neutrons of different energies for both types of TL dosemeters. Neutron sensitivity values for TLD-700 are related to LiF with 0.035% of Li-6 isotope. Result of measurement have also shown that the CaF 2 :Mn (TLD-08) thermoluminescent dosemeter is more suitable for gamma radiation dose measurements in mixed n-gamma fields with intensive neutron fluxes due to lower neutron sensitivity compared to TLD-700 [sr

  17. A CR-39 track dosemeter for routine individual neutron monitoring

    International Nuclear Information System (INIS)

    Luszik-Bhadra, M.; Alberts, W.G.; Dietz, E.; Guldbakke, S.; Matzke, M.; d'Errico, F.

    1994-01-01

    A personal neutron dosemeter for routine individual monitoring is proposed. It is based on a CR-39 track detector covered on three separate areas by converters with different boron contents and inserted into a commercial TLD albedo dosemeter capsule. The dose readings from three areas of the electrochemically etched CR-39 detector are combined to yield a dose equivalent response which is almost independent of the incident neutron energy in the range from thermal neutrons up to 20 MeV. In addition, the dose contributions of thermal, intermediate and fast neutrons can be determined separately. Unlike the TLD albedo dosemeter, which in general requires prior in-field calibration and whose use is then restricted to that field, this dosemeter can be used in neutron fields without any knowledge of the spectral distribution with the same calibration factor. The angular dependence of the dosemeter's response has been measured and compared with that of the directional dose equivalent H'(10). The lower limit of detection is 0.15 mSv. It is possible to obtain an independent, second dose reading from the same Cr-39 detector for neutron energies above 100 keV. The dosemeter has also been successfully tested for use in accident dosimetry applying chemical etching and an optical density reading of the CR-39 detector. (author)

  18. The use of TLD-700H dosemeters in the assessment of external doses at the former Semipalatinsk nuclear test site.

    Science.gov (United States)

    Hill, P; Dederichs, H; Pillath, J; Schlecht, W; Hille, R; Artemev, O; Ptitskaya, L; Akhmetov, M

    2002-01-01

    The joint projects performed since 1995 by the Jülich Research Centre in co-operation with the Kazakh National Nuclear Centre in the area of the former nuclear test site near Semipalatinsk, in eastern Kazakhstan, have assessed the current dose rate of the population at and around the test site, as well as determining retrospectively the dose rate of persons affected by the atmospheric tests. Measurements of the population by personal dosemeters depend on reliably wearing these dosemeters over prolonged periods of time, and of a sufficient dosemeter return. In the past, such measurements have been particularly successful whenever short wearing times were possible. This requires high sensitivity of the dosemeters. The suitability of the highly sensitive TLD material of the BICRON TLD 700H type for such personal dosimetry measurements was investigated. It was tested in practical field application at the Semipalatinsk nuclear test site in September 2000. Initial results are available from individual doses received by a group of geologists and a group of herdsmen at the test site. For the first time, the individual dose was measured directly in these population groups. Detection limits below 1 microSv permit informative measurements for wearing times of less than two weeks. Most individual doses did not arise significantly out of local fluctuations of natural background. A conservative assessment from the aspect of practical health physics yielded a mean personal dose of 0.55 microSv per day for the herdsmen, whereas the geologists received a mean personal dose of 0.45 microSv per day. For an annual exposure period of typically, about three months, the radiation dose received by the persons investigated, in addition to the natural radiation exposure, is thus well below the international limit value of 1 mSv x a(-1) for the population dose.

  19. Environmental effects on TLD 100

    International Nuclear Information System (INIS)

    Lilley, E.; Howard, R.

    1976-01-01

    Reference is made to a recent paper by Dhar et al (Health Phys.; 25:427 (1973)) in which significant differences in the sensitivity of TLD 100 crystals following the same heat treatments in different environments, were reported. Similar work is here reported on TLD 100 at 400 0 C with half the crystals being heat treated in vacuum, irradiated and readout an then annealed in air, irradiated and readout while the other half of the crystals were air annealed and readout before vacuum annealing and readout. In both cases no significant change was detected in contrast to the results of Dhar et al. (U.K.)

  20. The study of new calibration features in the Harshaw TLD system

    International Nuclear Information System (INIS)

    Luo, L. Z.

    2007-01-01

    The Harshaw TLD system has three key calibration procedures: the Reader, the Dosemeter and the Algorithm. These functions must be properly calibrated for the system to achieve the optimum results. For the conventional reader and dosemeter calibration, Harshaw TLD recommends a pre-fade and a post-fade of 24-48 h when calibrating the system for LiF:Mg,Ti type dosemeter. It is also recommended that keeping the fade time consistent is important to maintain the quality of the system performance. In recent years, new calibration features have been introduced into the Harshaw TLD models 6600 and 8800 operating systems. These new features are Auto Calibration, Auto QC and Auto Blank, and they give the user the ability to set up the clear-expose-read process to be performed automatically in a sequence for each dosemeter. This saves processing time and keeps the fade time the same. However, since the fade time is near zero, will it affect the TLD system calibration factors? What should the user expect? This paper presents a study of the effect of Auto Calibration/Auto QC to the TLD operation. (authors)

  1. Postal TLD audit in radiotherapy in the Czech Republic

    International Nuclear Information System (INIS)

    Kapucianova, M.; Ekendah, D. l.; Bulanek, B.

    2014-01-01

    The postal TLD audit in radiotherapy is an independent check of dose applied by radiotherapy centers. Our poster provides basic information on the methodology of dose determination within the TLD audit. An overview of different versions of the TLD audit that are focused on specific techniques in radiotherapy is given. We also present results of so called basic version of the TLD audit that is performed regularly for purposes of the State Office for Nuclear Safety. Moreover, results of intercomparison measurements organized by the IAEA (International Atomic Energy Agency), in which our laboratory takes part every year, are shown.The methodology of dose determination is based on TL measurement of LiF:Mg,Ti powder. The TL dosemeter (TLD) has form of a plastic capsule containing approximately 160 mg of this material. Before the TL reading, the powder of each particular irradiated dosemeter is divided into 9 identical samples by means of an accurate dispenser. The dosemeter response is given as average of TL responses of the 9 samples. The dose absorbed in water is computed from the TLD response by application of calibration factor and correction coefficients for elimination of energy dependence, supra-linearity and fading of the TL material. The evaluation of the TLD audit is based on comparison of the dose measured by the TLD and the dose stated by a radiotherapy center. Relative deviation between these doses is calculated. Several versions of the TLD audit are available. (authors)

  2. Evaluation of personal dosemeters and comparative measurements performed by PTB in the years 1979 through 1984. Pt. 1

    International Nuclear Information System (INIS)

    Boehm, J.; Buchholz, G.

    1986-01-01

    Comparison measurements of the official individual dosemeters performed in the PTB from 1979 to 1984 are described. Also a number of other, unofficial individual dosemeters participated. The performance of the comparison measurements and the types of the individual dosemeters are described. Tables show the values measured with the film dosemeters, with film and TLD dosemeters, and TLD dosemeters as well as dosimetric probes for whole-body and partial body dose measurement. (DG) [de

  3. Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters

    International Nuclear Information System (INIS)

    Sanchez, R.M.; Vano, E.; Fernandez, J.M.; Ginjaume, M.; Duch, M.A.

    2014-01-01

    The purpose of this paper is to test the appropriateness of OSL and electronic dosemeters to estimate eye lens doses at interventional cardiology environment. Using TLD as reference detectors, personal dose equivalent was measured in phantoms and during clinical procedures. For phantom measurements, OSL dose values resulted in an average difference of 215 % vs. TLD. Tests carried out with other electronic dosemeters revealed differences up to ±20 % versus TLD. With dosemeters positioned outside the goggles and when TLD doses were >20 μSv, the average difference OSL vs. TLD was 29 %. Eye lens doses of almost 700 μSv per procedure were measured in two cases out of a sample of 33 measurements in individual clinical procedures, thus showing the risk of high exposure to the lenses of the eye when protection rules are not followed. The differences found between OSL and TLD are acceptable for the purpose and range of doses measured in the survey (authors)

  4. TL response of LiF: Mg, Cu, P dosemeters in function of the photon energy; Respuesta TL de dosimetros de LiF: Mg, Cu, P en funcion de la energia del foton

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, P.R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Azorin, J. [UAM-I, 09340 Mexico D.F. (Mexico); Furetta, C. [Universita degli Studi di Roma ' La Sapienza' , Piazzale Aldo Moro 2, 00185 Roma (Italy)

    2005-07-01

    In this work the obtained results of studying the response of dosemeters of LiF: Mg, Cu, P + Ptfe, developed in the ININ, commercial dosemeters GR200A (LiF: Mg, Cu, P) of chinese manufacture and TLD-100 (LiF: Mg, Ti) US are presented, when irradiating them with X rays 16, 24, 34.5, 42, 100 and 145 keV of effective energy, with gamma rays of 662 keV ({sup 137} Cs) and 1252 keV ({sup 60} Co). The results are presented in function of the sensitivity that the dosemeters showed normalized to gamma radiation of {sup 60} Co. It was appreciated that the dosemeters more equivalent to the tissue, they were those of LiF: Mg, Cu, P + Ptfe, while the less equivalent ones were the TLD-100. (Author)

  5. Analysis of QUADOS problem on TLD-ALBEDO personal dosemeter responses using discrete ordinates and Monte Carlo methods

    International Nuclear Information System (INIS)

    Kodeli, I.; Tanner, R.

    2005-01-01

    In the scope of QUADOS, a Concerted Action of the European Commission, eight calculational problems were prepared in order to evaluate the use of computational codes for dosimetry in radiation protection and medical physics, and to disseminate 'good practice' throughout the radiation dosimetry community. This paper focuses on the analysis of the P4 problem on the 'TLD-albedo dosemeter: neutron and/or photon response of a four-element TL-dosemeter mounted on a standard ISO slab phantom'. Altogether 17 solutions were received from the participants, 14 of those transported neutrons and 15 photons. Most participants (16 out of 17) used Monte Carlo methods. These calculations are time-consuming, requiring several days of CPU time to perform the whole set of calculations and achieve good statistical precision. The possibility of using deterministic discrete ordinates codes as an alternative to Monte Carlo was therefore investigated and is presented here. In particular the capacity of the adjoint mode calculations is shown. (authors)

  6. Data processing of personnel exposure in TLD and film systems

    International Nuclear Information System (INIS)

    Lerner, A.; Liav, N.; Eisen, Y.

    1979-01-01

    The program for the processing and storage of data on the personnel irradiation exposure in Israel is built on the data base of the Weizmann Institute of Science; it is a general program suitable for both TLD and film dosimetry. The TSO system helped bring up-to-date the data of the various collections in an interactive way. The introduction of the TLD dosemeters in the badge service required certain changes in the thinking line - this because the TLD being a personal dosemeter is returned into service after having been deciphered. This demands following up the dosemeter when the worker moves from unit to unit or after he had finished his work. The program takes into account the internal exposures,too and conforms to the new recommendation published in ICRP-26. (B.G.)

  7. The development of a personal dosemeter for use by aircraft crew

    International Nuclear Information System (INIS)

    Stokes, R.P.; Talbot, L.

    2000-01-01

    This paper describes preliminary work to develop a cosmic-radiation dosemeter for use by military aircraft crew. The dosemeter is based on a combination of CR-39 etched-track detectors and TLD-700 thermoluminescent detectors. It is intended that the CR-39 be used to assess the neutron dose, while the TLD-700 is used to assess the photon and charged particle dose. The sensitivity of CR-39 to the neutron component of cosmic radiation was estimated by irradiating samples of the plastic at the CERN-CEC High Energy Reference Field Facility. This facility produced a radiation field with a neutron spectrum resembling that of the neutron component of cosmic radiation a typical airflight altitudes. The response of the CR-39 was linear over the range of doses studied (0.2-6.0 mSv) and there was no significant fading in the six-month period after irradiation. The TLD-700 component of the dosemeter was calibrated using 137 Cs gamma rays. The response of the TLD-700 was linear over the range of doses studied (0-1.1 mSv) with no significant fade in the six-month period after irradiation. It was concluded that a combination of CR-39 and TLD-700 detectors would provide an effective cosmic-radiation dosemeter for use by military aircraft crew. (author)

  8. Effects of annealing on the sensitivity of LiF TLD-100 after repeated use for low dose measurements

    International Nuclear Information System (INIS)

    Ogunleye, O.T.; Richmond, R.G.

    1987-01-01

    The changes in sensitivity of LiF TLD-100 extruded ribbons subjected to repeated use up to 100 times were investigated. Three different annealing regimes were compared. The dosemeters were annealed at 400 0 C followed by (i) a slow or (ii) fast cooling to room temperature or (iii) utilising a 20 s readout process in the reader without a high temperature annealing at 400 0 C. Each of the three groups consisted of two sets of 20 chips each, with one set receiving 500 μ Gy of 90 Sr beta radiation and the other unirradiated. Sensitivity evaluations were performed every five cycles through the first 50 cycles, and on each tenth cycle thereafter. On the average, the fast cooled group maintained their integrity best, while a maximum variation in sensitivity of about 15% was observed in the irradiated set of the slowly cooled group. A permanent increase in sensitivity of at least 10% was observed for the set of dosemeters receiving radiation without annealing. Glow curve analyses showed an increase in the ratio of peaks 4 and 5 with repeated use of this group. (author)

  9. Personal and environmental dosimetric measurements using TLD method in Cardiac Catheterization Laboratory (CathLab) at the Rzeszow's Regional Hospital No 2, Poland

    International Nuclear Information System (INIS)

    Kisielewicz, K.; Truszkiewicz, A.; Wach, S.; Budzanowski, M.

    2007-01-01

    Complete test of publication follows. One of the basic problem in CathLab is the monitoring of ionizing radiation, calculations of doses for workers and finally to build a system to prevent workers from X-ray radiation. To measure doses from X-rays a passive method with thermoluminescent dosemeters (TLD) were applied. Experimental part was based on creating 3D grid of Tl environmental dosemeters with 2 high sensitive TL detectors based on MCP-N (LiF:Mg,Cu,P). Dosemeters were placed evenly (as far as staff's work conditions allowed such positioning) in operating room and a control room. Grid of about 100 dosemeters was designed to measure X-ray dose distribution present during interventional cardiology procedures. That part of the project was especially important for hospital's employee, because it has brought an information about most radiative dangerous areas of each room. Patient dosimetry measurements have been also made using TLD method just during the interventional cardiology procedures. Every patient got a few dosemeters dor different parts of body. Experimental part consists of measurements of absorbed dose equivalent, mean dose rate of absorbed dose equivalent, and mean dose of effective dose per each body part. That last measurements were accomplished by placing TLD's near patient's head, chest and gonads. Personal dosimetry for employees, has been made using TLD's during hemodynamics procedures. Every employee (medical doctors, nurses, technicians and charwoman) has received few dosemeters also based on high sensitive MCP-N detectors. The main dosimetry was done for whole body covered by led gown and additionally for unprotected parts: (hands, arm, eyes and protected by gown: chest, gonads). For individual dosimetry Hp(10) in mSv was calculated, while using environmental dosemeters KERMA in air in mGy. This work will present results obtained from ca. 100 environmental placed in CathLab room. Additionally personal doses for whole body and for parts of

  10. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative quantities ICRU, for external fields of beta radiation. Part II. I study of the angular response of personal dosemeters TLD-100 in secondary patron fields of beta radiation ({sup 90}Sr / {sup 90}Y); Medicion de dosis equivalente con dosimetros personales e instrumentos de proteccion radiologica en las nuevas magnitudes operativas ICRU, para campos de radiacion beta externos. Parte II. Estudio de la respuesta angular de dosimetros personales TLD-100 en campos patrones secundarios de radiacion beta ({sup 90}Sr/{sup 90}Y)

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1994-01-15

    The objective of this work is to carry out one of the possible ones test type for personal dosemeters TLD, under the recomendations of the ICRU 39, ICRU 43 and the draft of the norm ISO 6980,(1992), with the purpose of verifying the capacity of these detectors to carry out the operative unit: H' (0.07;{alpha}). Since H' (O. 07;{alpha}) this defined one in an expanded field, one of these tests type consist on determining the angular response of these detectors. 20 personal dosemeters TLD-100 was used, (card marks: Harshaw, Model: G-1, with two glasses of TLD-100 absorbed in teflon; the portadosemeters has two windows, a free one and another with a filter of Pb of 171.0 mg cm{sup -2}); these dosemeters they were previously selected, [to see, {sup S}tudy of the Homogeneity of the response of Personal Dosemeters (Cards G-l, TLD-100) in Radiation of Countrysides of {sup 60}Co{sup ,} J.T. Alvarez R. Technician Report GSR/IT/0001/94].The irradiations to effectued in secondary countryside of radiation beta of {sup 90}Sr/{sup 90}Y. The study was undertaken by means of an experimental design of blocks random that contemplate the following variables: intensity of the radiation source, (1850 MBq and 74 MBq); position of irradiation, (four positions); incidence of angle of the radiation (0, 15, 30, 45, 60 and 75 grades) and the absorbed dose in air, (0.005, 0.010, 0.020, 0.050 and 0.100 Gy). Then null hypothesis it was to suppose that there was not difference among the stockings of each treatment, to used the statistical of Duncan to carry out tests of stockings at a level of significance of 5%.These tests of stockings throw the following results in those variables of the experimental design: The irradiations carried out so much with the source pattern secondary of {sup 90}Sr/{sup 90}Y of 1850 MBq and of 74 MBq, they are equivalent reason why they can be used indistinctly. The responses of each one of the glasses of the card are strongly anisotropic for each glass

  11. Evaluation of the kinetic parameters of CaF2:Tm (TLD-300) thermoluminescence dosemeters

    International Nuclear Information System (INIS)

    Azorin, Juan; Gutierrez, Alicia; Furetta, Claudio

    1989-01-01

    The kinetic parameters of the first, third and fifth peaks of CaF 2 :Tm (TLD-300) dosemeters were determined experimentally using methods based on initial rise, peak shape, different heating rates, isothermal decay and numerical fitting method and a comparison was made between the results obtained. The average activation energy values determined by the methods used here were 0.72, 1.16 and 1.77 eV, with mean values for the frequency factor of 2.58 x 10 8 , 2.89 x 10 13 and 6.16 x 10 16 s -1 for the first, third and fifth peaks respectively. The values of activation energy obtained for each peak using the different methods covered a spread of about 4%. However, the spread for each of the frequency factors was very high. (author)

  12. Dose equivalent response of personal neutron dosemeters as a function of angle

    International Nuclear Information System (INIS)

    Tanner, J.E.; McDonald, J.C.; Stewart, R.D.; Wernli, C.

    1997-01-01

    The measured and calculated dose equivalent response as a function of angle has been examined for an albedo-type thermoluminescence dosemeter (TLD) that was exposed to unmoderated and D 2 O-moderated 252 Cf neutron sources while mounted on a 40 x 40 15 cm 3 polymethylmethacrylate phantom. The dosemeter used in this study is similar to many neutron personal dosemeters currently in use. The detailed construction of the dosemeter was modelled, and the dose equivalent response was calculated, using the MCNP code. Good agreement was found between the measured and calculated values of the relative dose equivalent angular response for the TLD albedo dosemeter. The relative dose equivalent angular response was also compared with the values of directional and personal dose equivalent as a function of angle published by Siebert and Schuhmacher. (author)

  13. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative magnitudes ICRU, for external fields of beta radiation. Part I. Study of the homogeneity of the response personal dosemeters leaves (cards G-1, TLD-100), in radiation fields of Co60

    International Nuclear Information System (INIS)

    Alvarez R, J.T.

    1994-01-01

    A sample of 40 composed personal dosemeters by cards model: G-l, (each card is made up of two TLD-100 crystals encapsulated in teflon), Harshaw trademark; those personal dosemeters present a free window and another with a filter of A1 of 171.7 mg cm -2 of mass thickness.The objective of the work is to select of this sample of 40 personal dosemeters a population with the same stocking and standard deviation. The technique used is that of comparison of stockings, (ANOVA; Variance Analysis, when samples of the same one were had size; and/or GLM, Widespread Lineal Models, when the samples were of different size), by means of the use of those Duncan statistics, SNK, Tukey, Gabriel; the results are validated proving the kindness of adjustment of the experimental data to a Normal distribution by means of the Shapiro-Wilks statistics.The experimental design used consists on a test of two vias: a via is the variable card with two levels, (crystal 1 and 2), the other via is the variable irradiation position with four levels, (LS=left superior, SR= right superior, LI= left Inferior, IR = right inferior). The irradiations carried out in blocks of four personal dosemeters in a gamma radiation beam range of Cobalt 60; carrying out three repetitions of the design. With object of proving the homogeneity of the filter of A1 in those personal dosemeters the experimental design was executed for those cards without personal dosemeters.They were also carried out tests of stockings to the readings of bottom and sensibility of the reader equipment, (Harshaw, model marks 2271), certain that doesn t exist differences for sequence of reading, but if in the stockings of the sensibility, (they were 4 different populations). The responses of the dosemeters were corrected subtracting him the reading correspondence of bottom and by sensibility of the reader equipment before subjecting them to the tests of stockings mentioned. Of the results of the tests of stockings for the cards with and

  14. Study of the influence of the time temperature profile on the minimum detectable dose of TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Meireles, Leonardo S.; Lacerda, Marco Aurelio S.; Meira-Belo, Luiz C.; Ferreira, Hudson R., E-mail: meirelesls@cdtn.br, E-mail: masl@cdtn.br, E-mail: lcmb@cdtn.br, E-mail: hrf@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    Monitoring of workers and workplaces is an integral part of any radiation protection programme (RPP). It is essential to demonstrate compliance with regulations that limit the allowable dose to the public from manmade sources and to enable the responsible of the installations to verify compliance with the legal dose limits to the workers and ALARA goals. Thermoluminescent dosemeters (TLDs) are generally employed to assess the environmental and personnel doses. To completely characterize a TLD dosimetry system is fundamental to determine the Lowest Dose that the system is capable of measuring. As the amount of the light emitted by TLD material is a function of the time temperature profile (TTP), in the present study, the influence of the TTP on the Detection Threshold (MDD) of the LiF:Mg,Ti (TLD-100) detectors was evaluated. Eighteen different TTPs were tested for two different annealing processes: (I) utilization of the TTP itself and; (II) a microprocessor controlled oven annealing procedure. Results showed that TTP choice can influence significantly in the MDD values. The worst results were generally found for TLDs annealed by the TTP itself. The lack of pattern or the unexpected behavior to the influence of some parameters of the TTP on the calculated MDDs must be carefully investigated. Greater variations on the TTP parameters must be undertaken. Special attention must be also done on the methodology of calculating the MDDs. (author)

  15. Study of the influence of the time temperature profile on the minimum detectable dose of TLD-100

    International Nuclear Information System (INIS)

    Meireles, Leonardo S.; Lacerda, Marco Aurelio S.; Meira-Belo, Luiz C.; Ferreira, Hudson R.

    2013-01-01

    Monitoring of workers and workplaces is an integral part of any radiation protection programme (RPP). It is essential to demonstrate compliance with regulations that limit the allowable dose to the public from manmade sources and to enable the responsible of the installations to verify compliance with the legal dose limits to the workers and ALARA goals. Thermoluminescent dosemeters (TLDs) are generally employed to assess the environmental and personnel doses. To completely characterize a TLD dosimetry system is fundamental to determine the Lowest Dose that the system is capable of measuring. As the amount of the light emitted by TLD material is a function of the time temperature profile (TTP), in the present study, the influence of the TTP on the Detection Threshold (MDD) of the LiF:Mg,Ti (TLD-100) detectors was evaluated. Eighteen different TTPs were tested for two different annealing processes: (I) utilization of the TTP itself and; (II) a microprocessor controlled oven annealing procedure. Results showed that TTP choice can influence significantly in the MDD values. The worst results were generally found for TLDs annealed by the TTP itself. The lack of pattern or the unexpected behavior to the influence of some parameters of the TTP on the calculated MDDs must be carefully investigated. Greater variations on the TTP parameters must be undertaken. Special attention must be also done on the methodology of calculating the MDDs. (author)

  16. Comparison of LiF (TLD-100 and TLD-100H) detectors for extremity monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Freire, L. [Departamento de Proteccao Radiologica e Seguranca Nuclear, Instituto Tecnologico e Nuclear, E.N. 10, 2683-953 Sacavem (Portugal); Laboratorio de Medicina Nuclear, Lda, Atomedical, Rua Helena Felix, 11D, 1600-121 Lisboa (Portugal); Calado, A.; Cardoso, J.V.; Santos, L.M. [Departamento de Proteccao Radiologica e Seguranca Nuclear, Instituto Tecnologico e Nuclear, E.N. 10, 2683-953 Sacavem (Portugal); Alves, J.G. [Departamento de Proteccao Radiologica e Seguranca Nuclear, Instituto Tecnologico e Nuclear, E.N. 10, 2683-953 Sacavem (Portugal)], E-mail: jgalves@itn.pt

    2008-02-15

    In this work the results aimed at assessing the performance of two types of LiF detectors, TLD-100 and TLD-100H, used in the context of extremity dosimetry are presented. Each detector variety was studied for reproducibility, batch homogeneity, residual dose, linearity and energy dependence using, when appropriate, the {sup 90}Sr/{sup 90}Y radiation source built-in one of the Harshaw 6600 readers, the ISO narrow X-ray beams of N30, N40, N60, N80, N100 and N120 or the gamma radiations of {sup 137}Cs and {sup 60}Co. Two calibration energies (N120 and {sup 137}Cs) were also used. The reproducibility and linearity results indicate that both LiF:Mg,Ti and LiF:Mg,Cu,P performed equally well. However, LiF:Mg,Cu,P presents a higher residual signal. In terms of energy dependence, LiF:Mg,Cu,P shows less variation than LiF:Mg,Ti particularly when N120 is used as calibration radiation. This seems to be a more realistic setup since the energy of the most frequently used radioisotopes in Nuclear Medicine departments with single photon emission computed tomography (SPECT) use gamma radiation energies closer to N120 than to {sup 137}Cs.

  17. PTTL Dose Re-estimation Applied to Quality Control in TLD-100 Based Personal Dosimetry

    International Nuclear Information System (INIS)

    Muniz, J.L.; Correcher, V.; Delgado, A.

    1999-01-01

    A new method for quality control of dose performance in Personal Dosimetry using TLD-100 is presented. This method consists of the application of dose reassessment techniques based on phototransferred thermoluminescence (PTTL). Reassessment is achieved through a second TL readout of the dosemeters worn by the controlled workers, after a reproducible UV exposure. Recent refinements in the PTTL technique developed in our laboratory allow reassessing doses as low as 0.2 mSv, thus extending the reassessment capability to the entire dose range that must be monitored in personal dosimetry. After a one month exposure, even purely environmental doses can be reassessed. This method can be applied for either re-estimation of single doses or of the total dose accumulated after a number of exposures and dose measurements. Several tests to reconfirm low doses in normal working conditions for personal dosimetry have been performed. Each test consisted of several cycles of exposure and TL evaluations and a final PTTL re-estimation of the total accumulated dose in those cycles. The results obtained always showed very good agreement between the sum of the partial doses and the total reassessed dose. The simplicity of the method and the possibility of re-evaluating the doses assessed to the workers employing their own dosemeters are advantageous features to be considered in designing systems for the determination of real performance in personal dosimetry. (author)

  18. Application of radiophotoluminescence dosemeters for environmental monitoring

    International Nuclear Information System (INIS)

    Mihara, A.; Tamura, T.; Mochizuki, T.; Numakunai, T.; Yoshida, Y.; Ohi, Y.

    1993-01-01

    Feasibility study has been made on the radiofluorescence glass (RPL) dosemeters for environmental radiation monitoring. Main items in the laboratory tests are batch uniformities of pre-dose and sensitivity, build-up characteristics of RPL intensity, energy and angular responses, stabilities for RPL reading, anneal cycling and climatic conditional changes. We have determined self-irradiation dose and cosmic ray contribution. Radiation monitoring field test for the RPL dosemeters has been conducted in comparison with the present TLD systems. A procedure manual for the environmental monitoring by the use of RPL dosemeters is in preparation

  19. The use of active personal dosemeters as a personal monitoring device: Comparison with TL dosimetry

    International Nuclear Information System (INIS)

    Boziari, A.; Koukorava, C.; Carinou, E.; Hourdakis, C. J.; Kamenopoulou, V.

    2011-01-01

    The use of active personal dosemeters (APDs) not only as a warning device but also, in some cases, as an official and hence stand-alone dosemeter is rapidly increasing. A comparison in terms of dose, energy and angle dependence, among different types of APD and a routinely used whole-body thermoluminescence dosemeter (TLD) has been performed. Significant differences were found between the TLD readings and mainly some not commonly used APDs. The importance of choosing the best adapted APD according to the radiation field characteristics is pointed out. (authors)

  20. Factors affecting polyamide prototypes design of Albedo dosemeters

    International Nuclear Information System (INIS)

    Martins, M.M.; Mauricio, C.L.P.; Fonseca, E.S.

    1996-01-01

    This work studies the most important factors which affect the response of albedo neutron dosemeters containing LiF TLDs with the aim to improve their sensitivity. It includes tests of thickness and shape of the polyamide moderator body prototypes, albedo window diameter and TLD position inside the moderator. Analyzing the results, an albedo neutron dosemeter prototype, B 4 C covered, was developed. The prototype has a response three times higher than the albedo dosemeter now in use in Brazil. (author)

  1. Personal neutron diode dosemeter

    International Nuclear Information System (INIS)

    Barthe, J.; Lahaye, T.; Moiseev, T.; Portal, G.

    1993-01-01

    The control and management of neutron doses, received by workers in nuclear power or research facilities, requires a knowledge of cumulated dose equivalent or dose equivalent rate in real time. Individual dosemeters so far developed for this purpose are scarce and not very satisfactory. Passive dosemeters such as TLD systems based on the albedo effect, nuclear emulsions or solid track detectors, do not give sufficiently accurate measurements. Furthermore, the increase in the quality factor and the more restrictive new ICRP recommendations diminish the maximum admissible threshold making currently used systems obsolete. Other than bubble dosemeter systems, based on thermodynamic effects of a superheated gel, no simple electronic device is available at the present time. The development of diode based dosimetric gamma badges, having a size similar to that of credit cards, has stimulated us to design and develop a personal neutron dosemeter based on a double diode system. The results obtained are very encouraging and practical models should become available in the near future. (author)

  2. The new IRSN passive dosemeter using the RPL technique

    International Nuclear Information System (INIS)

    Fraboulet, P.; Cale, E.; Itie, C.; Bottollier-Depois, Jean-Francois

    2008-01-01

    Full text: The Institute for Radiological Protection and Nuclear Safety (IRSN) is the French public organisation in charge of research and expertise into nuclear safety and radiation protection. IRSN provides also services in these areas like dosimetric survey for 150,000 workers liable to be exposed to ionising radiation. At present whole-body dosemeters provided by the IRSN laboratory for photons and beta-particles are based on photographic films. In order to anticipate likely supplying decrease and to improve the service, IRSN has decided to replace photographic films by dosemeters based on the radio-photoluminescence (RPL) technology, supplied by the Japanese Company Chiyoda Technol. RPL was chosen after a thorough comparison with other available passive techniques (thermoluminescent dosemeters: TLD, and optically stimulated luminescence: OSL). Constraints due to large-scale production of dosemeters (packaging, shipping, etc.) were taken into account as well. Irradiation tests for five different dosemeters, based on the 3 available techniques (TLD, OSL, RPL) were performed. The main results of these tests are presented (energy, dose and angular response, detection threshold, etc.) together with main technical characteristics of the new RPL dosemeter (range in energy and dose, homogeneity, reproducibility, re-reading, information about radiation type from reading, etc.). This dosemeter is expected to give significative improvements in the IRSN laboratory's provision of service thanks to better dosimetric performances and because it offers the possibility to get information to analyse over-exposure circumstances. (author)

  3. A method to minimise the fading effects of LiF:Mg,Ti (TLD-600 and TLD-700) using a pre-heat technique.

    Science.gov (United States)

    Lee, YoungJu; Won, Yuho; Kang, Kidoo

    2015-04-01

    Passive integrating dosemeters [thermoluminescent dosimeter (TLD) and optically stimulated luminescence (OSL)] are the only legally permitted individual dosemeters for occupational external radiation exposure monitoring in Korea. Also its maximum issuing cycle does not exceed 3 months, and the Korean regulations require personal dosemeters for official assessment of external radiation exposure to be issued by an approved or rather an accredited dosimetry service according to ISO/IEC 17025. KHNP (Korea Hydro & Nuclear Power, LTD), a unique operating company of nuclear power plants (NPPs) in Korea, currently has a plan to extend a TLD issuing cycle from 1 to 3 months under the authors' fading error criteria, ±10%. The authors have performed a feasibility study that minimises post-irradiation fading effects within their maximum reading cycle employing pre-heating technique. They repeatedly performed irradiation/reading a bare TLD chip to determine optimum pre-heating conditions by analysing each glow curve. The optimum reading conditions within the maximum reading cycle of 3 months were decided: a pre-heating temperature of 165°C, a pre-heating time of 9 s, a heating rate of 25°C s(-1), a reading temperature of 300°C and an acquisition time of 10 s. The fading result of TLD-600 and TLD-700 carried by newly developed time temperature profile (TTP) showed a much smaller fading effect than that of current TTP. The result showed that the fading error due to a developed TTP resulted in a ∼5% signal loss, whereas a current TTP caused a ∼15% loss. The authors also carried out a legal performance test on newly developed TTP to confirm its possibility as an official dosemeter. The legal performance tests that applied the developed TTP satisfied the criteria for all the test categories. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Application of beta transmission for quality assurance of TLD tape dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, J.S.; Gupta, S.K.; Supe, S.J. (Bhabha Atomic Research Centre, Bombay (India). Div. of Radiological Protection)

    1993-03-01

    Transmission of [sup 204]Tl [beta] radiation enables measurement of differences of [+-] 2 mg/cm[sup 2] in thermoluminescent tape dosemeter thickness. This thickness variation gives rise to a maximum variation of [+-] 5% in the TL output per unit area of the dosemeters. Measurements of [beta] transmission on dosemeter samples drawn from several batches of skived tape as well as those prepared by compressing technique have given consistent results. The [beta] transmission method itself can be used for quality assurance and selection of a uniform set of dosemeters over thickness range 30-150 mg/cm[sup 2]. (author).

  5. Response of TLD-100"T"M microtubes to two RQR3 quality radiation beams

    International Nuclear Information System (INIS)

    Nunes, M.G.; Villani, D.; Almeida, S.B.; Vivolo, V.; Yoriyaz, H.; Louis, G.M.J.

    2016-01-01

    The present work compares the response of TLD-100"T"M microcubes to two RQR 3 diagnostic radiology reference quality radiation beams, defined by IEC-61267 norm, aiming to evaluate the detectability of TLD-100"T"M energy dependence reported in literature within the same reference quality radiation range. TLD-100"T"M microcubes reproducibility is assessed through the response of a second set of TLD-100"T"M microcubes, evaluated in a second thermoluminescence reader, to the RQR 3 diagnostic radiology reference quality radiation beam implemented at the Laboratorio de Calibracao de Instrumentos of IPEN, Sao Paulo, SP, Brazil. The dependence of TLD-100"T"M microcubes TL response was not detectable in these conditions and the reproducibility of the measurements is 90,2%. (author)

  6. Dosimetric evaluation of the response of the TLD-100 dosemeters in the IMRT technique by 'Step and Shoot'

    International Nuclear Information System (INIS)

    Vasquez, J.; Benavides, S.O.

    2005-01-01

    We show the results of the dosimetry response of LiF thermoluminescent crystals: TLD-100, where they were radiated in a linear accelerator Siemens Primus Hl using the Intensity Modulated Radiation Therapy (IMRT) by step and shoot technique. Previous to the crystals calibration and response evaluation, the acceptation procedures recommended by the TG-53 protocol for validation of the technique were carried out. The planning system utilized was the Theraplan Plus 3.8, using the algorithm of Pencil Kernel. The register and verification system was Lantis 5.2. The response curve of dose versus charge was obtained from the readings of the TLD in a Harshaw 3500. The crystals were radiated in a Bench- Marck phantom with doses previously determined by using ionization chambers for square radiation fields, in a beam with a 0.68 TPR20,10 corresponding to 6 MV of energy. We compare the response of these through of radiation of segmented fields in a Anthropomorphic phantom and the calculated doses by the planning system. The results obtained in the crystals response show deviations less than 5 % between the measured dose and the calculated dose in the zones of low gradient. It allows its implementation like routine control of quality by IMRT. (Author)

  7. Alanine and TLD coupled detectors for fast neutron dose measurements in neutron capture therapy (NCT)

    Energy Technology Data Exchange (ETDEWEB)

    Cecilia, A.; Baccaro, S.; Cemmi, A. [ENEA-FIS-ION, Casaccia RC, Via Anguillarese 301, 00060 Santa Maria di Galeria, Rome (Italy); Colli, V.; Gambarini, G. [Dept. of Physics of the Univ., INFN, Via Celoria 16, 20133 Milan (Italy); Rosi, G. [ENEA-FIS-ION, Casaccia RC, Via Anguillarese 301, 00060 Santa Maria di Galeria, Rome (Italy); Scolari, L. [Dept. of Physics of the Univ., INFN, Via Celoria 16, 20133 Milan (Italy)

    2004-07-01

    A method was investigated to measure gamma and fast neutron doses in phantoms exposed to an epithermal neutron beam designed for neutron capture therapy (NCT). The gamma dose component was measured by TLD-300 [CaF{sub 2}:Tm] and the fast neutron dose, mainly due to elastic scattering with hydrogen nuclei, was measured by alanine dosemeters [CH{sub 3}CH(NH{sub 2})COOH]. The gamma and fast neutron doses deposited in alanine dosemeters are very near to those released in tissue, because of the alanine tissue equivalence. Couples of TLD-300 and alanine dosemeters were irradiated in phantoms positioned in the epithermal column of the Tapiro reactor (ENEA-Casaccia RC). The dosemeter response depends on the linear energy transfer (LET) of radiation, hence the precision and reliability of the fast neutron dose values obtained with the proposed method have been investigated. Results showed that the combination of alanine and TLD detectors is a promising method to separate gamma dose and fast neutron dose in NCT. (authors)

  8. Determination of kinetic parameters in Tl dosemeters of LiF: Mg, Cu, P + PTFE developed in the ININ

    International Nuclear Information System (INIS)

    Basurto G, B.S.

    2002-01-01

    The objective of this work, is the one of determining the kinetic parameters of the dosemeter of LiF: Mg, Cu, P + Ptfe; starting from the curves Tl obtained at being irradiated with alpha radiation (α), beta (β) and gamma (γ). As like to compare its sensitivity with each radiation type, considering the sensitivity of the TLD-100 as the unit. In the Chapter 1, the fundamental structure of the matter is described, making emphasis in the different radiation types, and their interaction with this. In the Chapter 2, the units are described but used in the dosimetry of the radiation. In the Chapter 3, the basic concepts of the phenomenon of Tl are described and those are explained characteristic of the deconvolution method to determine the kinetics of the one phenomenon. In the Chapter 4, the methodology is detailed that was used in the elaboration of this thesis work, describing the material Tl that were considered like reference, as well as the sources of ionizing radiation, with those that the dosemeters were irradiated and the equipment in the one that the curves Tl was obtained. Reference is made to the software used to carry out the deconvolution of the curves Tl that were obtained in the one experimental development. In the Chapter 5, the obtained results of this study are presented, showing the tables of homogenization of dosemeters and the reading of the same one; they are observed the curves Tl obtained to different radiation doses (alpha, beta and gamma), the intensity Tl in function of the dose. Also they are tabulated, the obtained results in the kinetic parameters of the three different study materials (TLD-100H, USA; TLD-100, USA and LiF: Mg, Cu, P + Ptfe developed in the l.N.l.N). They are analyzed shortly for each material Tl their sensitivity to the ionizing radiation as well as their kinetic parameters. The obtained results showed that the Tl dosemeters of LiF: Mg,Cu,P + Ptfe, they presented a bigger sensitivity that the TLD-100 when being

  9. Determination of the TLD-100 physical parameters; Determinacion de parametros fisicos del TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Paucar J, J.; Picon C, C. [Instituto Nacional de Enfermedades Neoplasicas. INEN. Av. Angamos Este 2520, Lima 34 (Peru)

    1998-12-31

    This study was realized in the Physics service at the Radiotherapy Department of the National Institute of Neoplasic Diseases in Lima, Peru, it was determined the activation energy, the kinetic order and the frequency factor of the fifth peak of the TLD-100 thermoluminescent spectra using different algorithms. This was carried out in parallel with the implementation and design of a software and an interface associated with the Tl lecturer which allows a semiautomatic control for a thermoluminescent lecturer process. (Author)

  10. Environmental dose measurement with microprocessor based portable TLD reader

    International Nuclear Information System (INIS)

    Deme, S.; Apathy, I.; Feher, I.

    1996-01-01

    Application of TL method for environmental gamma-radiation dosimetry involves uncertainty caused by the dose collected during the transport from the point of annealing to the place of exposure and back to the place of evaluation. Should an accident occur read out is delayed due to the need to transport to a laboratory equipped with a TLD reader. A portable reader capable of reading out the TL dosemeter at the place of exposure ('in situ TLD reader') eliminates the above mentioned disadvantages. We have developed a microprocessor based portable TLD reader for monitoring environmental gamma-radiation doses and for on board reading out of doses on space stations. The first version of our portable, battery operated reader (named Pille - 'butterfly') was made at the beginning of the 80s. These devices used CaSO 4 bulb dosemeters and the evaluation technique was based on analogue timing circuits and analogue to digital conversion of the photomultiplier current with a read out precision of 1 μGy and a measuring range up to 10 Gy. The measured values were displayed and manually recorded. The version with an external power supply was used for space dosimetry as an onboard TLD reader

  11. Personal neutron monitoring using TLD albedo combined with etched tracks detector

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, N.; Momose, T. [Japan Nuclear Cycle Development Institute, Ibarakiken (Japan)

    2002-07-01

    The albedo dosimetry has been carried out in personal neutron monitoring in the MOX fuel plant of JNC Tokai Works, however, it has shortcomings mainly due to the inherently poor energy response. This paper describes our efforts to overcome these difficulties in practical use of albedo dosemeters. The following four subjects are presented: (1) the neutron energy response functions of albedo TLD obtained from the mono-energetic neutron irradiation experiments and the Monte-Carlo calculations, (2) the location- dependent correction factors calculated from the response functions and neutron energy spectra measured in the workplaces, (3) the results of the international personal neutron dosimetry intercomparison program, and (4) the operational comparison program of TLD albedo and etched tracks detector worn by workers engaged in the fabrication process of the MOX fuel plant. Finally, the characteristics of the combination neutron dosemeter using TLD albedo and solid state etched track detector are summarized.

  12. Verification of Ca F2:Mn type of dosemeters for personal dosimetry purposes

    International Nuclear Information System (INIS)

    Misovic, M.; Boskovic, Z.; Spasic-Jokic, V.

    1995-01-01

    Verification results of CaF2:Mn type of dosemeters for personal dosimetry purposes are presented in this paper. Tree types of irradiations are proceeded due to verification of relevant features of TLD. It is concluded that mentioned type of dosemeter can be used for purpose of personal dosimetry. (author)

  13. Environmental monitoring with a portable TLD system

    Energy Technology Data Exchange (ETDEWEB)

    Szabo, P P; Feher, I; Deme, S; Szabo, B; Vagvoelgyi, J; German, E [Hungarian Academy of Sciences, Budapest. Central Research Inst. for Physics

    1984-01-01

    Two types of TLD systems are used for environmental dose monitoring. One is based on an NHZ-203 laboratory TLD reader and CaSO/sub 4/:Dy powder. The other is based on CaSO/sub 4/:Tm bulbs and a small, portable TLD reader built into a cross-country car and operated by means of the car battery. The laboratory TLD system has been used for many years for environmental monitoring and it has been tested and proved satisfactory at international intercomparisons for environmental dosemeters. The new portable TLD system has the advantage of being able to establish the dose in a few minutes at the environmental station. The transport dose is omitted as the TLDs are evaluated at the field site. The evaluation of a bulb needs only a few minutes and the measured dose value can be reported back by radio - an important aspect during an emergency situation.

  14. Evaluation of mixed energy neutron doses using TLD NG-67 type

    International Nuclear Information System (INIS)

    Akhadi, Mukhlis; Thoyib Thamrin, M; Usmiyati Dewi, K.

    2000-01-01

    A research has been carried out to develop dose evaluation method of mixed neutron source with its neutron doses can be classified to two groups, I.e neutron doses with energy ≥ 0.5 eV and thermal neutron doses with energy less than 0.5 e V consist of epithermal and fast neutron, but in this research they were classified as fast neutron. Development of this dose evaluation method was carried out by sensitivity (S) intercomparison of TLD-600 to fast neutron, mixed energy neutron of nuclear rectors, and thermal neutron. From the experiment it was obtained that the value of Sfast : Sreactor : Sthermal = 0.005 : 0.010 : 1. Calibration factor (CF) of TLD is defined as 1/S. from the sensitivity data it can be obtained that the value of Cffast : Cfreactor : Cfthermal = 200 :100 : 1. The value of Cfreactor can be applied for mixed energy neutron doses evaluation of TLD-600. Key word : dosemeter, neutron dose, calibration factor, fast neutron, thermal neutron, nuclear reactor

  15. Utilization of thermoluminescent dosemeters for determination of exposure or absorbed dose in a radiation gamma or X radiation field with unknown spectral distribution

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da.

    1981-06-01

    Having in view the choice of the best pair of dosemeters to be used in the 'Tandem' method, the main response characteristics of LiF:Mg, Ti, Li 2 B 4 O 7 :Mn, CaSO 4 Dy, CaF 2 :Mn and CaF 2 :Dy thermoluminescent dosemeters and also some critical parameters in their calibration and evaluation processes were studied. Three different physical forms of TLD's were investigated: hot pressed chips, disc teflon dosemeters and glass mini TLD's. Their calibration factors were obtained for the energy of Cobalt-60 gamma rays. Their energy dependences normalized to 60 Co radiation were determined using spectral width as parameter. 'Tandens' formed by all TLD's evaluated were compaired. (E.G.) [pt

  16. Evaluation of BICRON NE MCP DXT-RAD passive extremity dosemeter

    CERN Document Server

    Yuen, P S; Frketich, G; Rotunda, J

    1999-01-01

    Passive extremity dosemeters currently used in dosimetry communities worldwide have shortcomings. In general, an extremity dosemeter has too thick a detector element, and the dosemeter response is highly energy dependent for beta rays with energies ranging from 200 keV to 2 MeV. It often does not have dosemeter identification, causing problems in the chain of custody. It is often read manually, rendering reading/packing operations very labour intensive. As a result of collaboration between AECL and BICRON NE, a new extremity dosemeter, incorporating a highly sensitive LiF:Mg,Cu,P TLD and tentatively code named MCP DXT-RAD, was developed. It has been evaluated for radiological performance against an ISO draft standard for extremity dosemeters in twelve categories: homogeneity, detection threshold, beta ray energy response, beta angular response, photon energy response, photon angular response, reproducibility, stability under various climatic conditions, linearity, residue, self irradiation, and effect of ligh...

  17. Intercomparison of Environmental Dosemeters Using Various TL Materials and Dosimetry Systems

    International Nuclear Information System (INIS)

    Crnic, B.; Gobec, S.; Zorko, B.; Knezevic, Z.; Majer, M.; Ranogajec-Komor, M.

    2013-01-01

    The aim of the present work was to compare the ambient dose equivalent (H*(10)) values determined at 20 sites around NPP Krško, using different thermoluminescence (TL) materials and various dosimetry systems. The H*(10) was measured by the CaF 2 :Mn (TLD-400) provided by the Jozef Stefan Institute (JSI) Ljubljana, Slovenia. These dosemeters were deployed in the environment in plastic bags and suspended inside the plastic bottles. On the other hand the Ruder Boskovic Institute (RBI), Zagreb, Croatia applied LiF:Mg,Cu,P (TLD-100H), CaF 2 :Mn, Al 2 O 3 :C TL detectors and radiophotoluminescence (RPL) glass dosemeters type SG1. They were placed at the same locations in as much as possible same conditions as JSI detectors. According to the protocol established for this intercomparison, the control and transport detectors (not deployed in the environment) were held in dark storage containers and used to determine the background radiation. The TL responses were corrected for individual sensitivity of the TL detectors which is an important factor after the calibration irradiations. The calibration irradiations were performed by 137Cs sources provided in Secondary Standard Dosimetry Laboratory facilities at the JSI and RBI. The results obtained by different TL materials and different dosimetry systems show interesting features especially concerning local environmental peculiarities. The H*(10) obtained by the dosemeters of various types deployed in the countryside fluctuate less than 10 %. The outcome should emphasize also in the manner that the results obtained and reported in the intercomparison are traceable to the primary standards.(author)

  18. SU-E-I-09: Application of LiF:Mg,Cu (TLD-100H) Dosimeters for in Diagnostic Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Sina, S [Radiation Research Center, Shiraz University, Shiraz (Iran, Islamic Republic of); Zeinali, B; Karimipourfard, M; Lotfalizadeh, F; Sadeghi, M [Nuclear Engineering Department, Shiraz University, Shiraz (Iran, Islamic Republic of); Faghihi, R [Radiation Research Center, Shiraz University, Shiraz (Iran, Islamic Republic of); Nuclear Engineering Department, Shiraz University, Shiraz (Iran, Islamic Republic of)

    2014-06-01

    Purpose: Accurate dosimetery is very essential in diagnostic radiology. The goal of this study is to verify the application of LiF:Mg,Cu,P (TLD100H) in obtaining the Entrance skin dose (ESD) of patients undergoing diagnostic radiology. The results of dosimetry performed by TLD-100H, were compared with those obtained by TLD100, which is a common dosimeter in diagnostic radiology. Methods: In this study the ESD values were measured using two types of Thermoluminescence dosimeters (TLD-100, and TLD-100H) for 16 patients undergoing diagnostic radiology (lumbar spine imaging). The ESD values were also obtained by putting the two types of TLDs at the surface of Rando phantom for different imaging techniques and different views (AP, and lateral). The TLD chips were annealed with a standard procedure, and the ECC values for each TLD was obtained by exposing the chips to equal amount of radiation. Each time three TLD chips were covered by thin dark plastic covers, and were put at the surface of the phantom or the patient. The average reading of the three chips was used for obtaining the dose. Results: The results show a close agreement between the dose measuered by the two dosimeters.According to the results of this study, the TLD-100H dosimeters have higher sensitivities (i.e.signal(nc)/dose) than TLD-100.The ESD values varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for measurements. Conclusion: The TLD-100H dosimeters are suggested as effective dosimeters for dosimetry in low dose fields because of their higher sensitivities.

  19. SU-E-I-09: Application of LiF:Mg,Cu (TLD-100H) Dosimeters for in Diagnostic Radiology

    International Nuclear Information System (INIS)

    Sina, S; Zeinali, B; Karimipourfard, M; Lotfalizadeh, F; Sadeghi, M; Faghihi, R

    2014-01-01

    Purpose: Accurate dosimetery is very essential in diagnostic radiology. The goal of this study is to verify the application of LiF:Mg,Cu,P (TLD100H) in obtaining the Entrance skin dose (ESD) of patients undergoing diagnostic radiology. The results of dosimetry performed by TLD-100H, were compared with those obtained by TLD100, which is a common dosimeter in diagnostic radiology. Methods: In this study the ESD values were measured using two types of Thermoluminescence dosimeters (TLD-100, and TLD-100H) for 16 patients undergoing diagnostic radiology (lumbar spine imaging). The ESD values were also obtained by putting the two types of TLDs at the surface of Rando phantom for different imaging techniques and different views (AP, and lateral). The TLD chips were annealed with a standard procedure, and the ECC values for each TLD was obtained by exposing the chips to equal amount of radiation. Each time three TLD chips were covered by thin dark plastic covers, and were put at the surface of the phantom or the patient. The average reading of the three chips was used for obtaining the dose. Results: The results show a close agreement between the dose measuered by the two dosimeters.According to the results of this study, the TLD-100H dosimeters have higher sensitivities (i.e.signal(nc)/dose) than TLD-100.The ESD values varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for measurements. Conclusion: The TLD-100H dosimeters are suggested as effective dosimeters for dosimetry in low dose fields because of their higher sensitivities

  20. Method of making isodose curve using thermoluminescence dosemeter

    International Nuclear Information System (INIS)

    Bakar Ramain, A.

    1975-01-01

    Line source of 60 Co in the form of needles and tubes are extensively used in radiotherapy in moulds, implants, and intracavitary techniques for the treatment of malignant lesions. It is important to have isodose distributions in tissue for those source for purposes of treatment planning. The isodose distributions have been obtained experimentally by using tinny lithium-fluoride (Lsub(i)F) thermoluminescent dosemeters (TLD) and they are compared to the theoretical results. The distinct advantages of Lsub(i)F (TLD) in such measurements are briefly discussed. (author)

  1. Investigation of LiF, Mg and Ti (TLD-100) Reproducibility.

    Science.gov (United States)

    Sadeghi, M; Sina, S; Faghihi, R

    2015-12-01

    LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses of 81 mGy (two times), 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%.

  2. Thermoluminescent dosemeter in a X-ray diffractometer

    International Nuclear Information System (INIS)

    Mendoza A, D.; Gonzalez M, P.; Falcon B, T.; Castano, V.M.

    1999-01-01

    In this work it was presented the results obtained of the dosimetry which was realized in a X-ray diffractometer for powders, trademark Siemens D5000, using the thermoluminescent signal generated by the X-rays in the commercial dosemeter TLD-100 of Harshaw, US. In according to the results obtained, the radiation quantity received by an analysed material in the diffractometer, will be proportional to exposure time and it can vary from unities until tenths of grays. These results are very outstanding when are analysed crystalline materials in a diffractometer, for knowing the present crystalline phases, mainly if these are highly sensitive to the ionizing radiation, as it is the case of the thermoluminescent materials. (Author)

  3. Investigation of LiF, Mg and Ti (TLD-100 Reproducibility

    Directory of Open Access Journals (Sweden)

    Sadeghi M.

    2015-12-01

    Full Text Available LiF, Mg and Ti cubical TLD chips (known as TLD-100 are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC were obtained 4 times by irradiating them to doses of 81 mGy (two times, 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%.

  4. Improvement of personal dosimetry - Digital pocket dosemeter

    International Nuclear Information System (INIS)

    Radalj, Z.; Cerovac, Z.; Cerovac, H.; Brumen, V.; Prlic, I.

    1996-01-01

    Physical dosimetric surveillance of professional groups working with various radiation sources is a regular procedure in Croatia, established almost 40 years ago. Data available point out that the majority of professionals under surveillance are those employed in medical facilities, most of them working with X-ray sources. Depending on the nature of professional activities, personnel occupationally exposed to radiation sources are obliged to wear either film badge, TLD or film+TLD badge. Unfortunately, due to the line of data processing, all standard dosemeters have the same disadvantage i.e. up to 40 days delay in dose reporting, regarding the time of actual exposure. The significance of such a delay raises in cases when radiation dose was received within the short time or when technical failure on the operating unit(s) is suspected. Bearing this in mind, the additional dosimetric monitoring becomes an imperative. Therefore, we decided to introduce a palette of digital pocket dosemeters, meant to be used in different workplaces in the radiation zone, each of them being adjusted to the specificities of a particular workplace

  5. Validation of response simulation methodology of Albedo dosemeter

    International Nuclear Information System (INIS)

    Freitas, B.M.; Silva, A.X. da

    2016-01-01

    The Instituto de Radioprotecao e Dosimetria developed and runs a neutron TLD albedo individual monitoring service. To optimize the dose calculation algorithm and to infer new calibration factors, the response of this dosemeter was simulated. In order to validate this employed methodology, it was applied in the simulation of the problem of the QUADOS (Quality Assurance of Computational Tools for Dosimetry) intercomparison, aimed to evaluate dosimetric problems, one being to calculate the response of a generic albedo dosemeter. The obtained results were compared with those of other modeling and the reference one, with good agreements. (author)

  6. Reproducibility Test for Thermoluminescence Dosimeter (TLD) Using TLD Radpro

    International Nuclear Information System (INIS)

    Nur Khairunisa Zahidi; Ahmad Bazlie Abdul Kadir; Faizal Azrin Abdul Razalim

    2016-01-01

    Thermoluminescence dosimeters (TLD) as one type of dosimeter which are often used to substitute the film badge. Like a film badge, it is worn for a period of time and then must be processed to determine the dose received. This study was to test the reproducibility of TLD using Radpro reader. This study aimed to determine the dose obtained by TLD-100 chips when irradiated with Co-60 gamma source and to test the effectiveness of TLD Radpro reader as a machine to analyse the TLD. Ten chips of TLD -100 were irradiated using Eldorado machine with Co-60 source at a distance of 5 meters from the source with 2 mSv dose exposure. After the irradiation process, TLD-100 chips were read using the TLD Radpro reader. These steps will be repeated for nine times to obtain reproducibility coefficient, r i . The readings of dose obtained from experiment was almost equivalent to the actual dose. Results shows that the average value obtained for reproducibility coefficient, r i is 6.39 % which is less than 10 %. As conclusion, the dose obtained from experiment considered accurate because its value were almost equivalent to the actual dose and TLD Radpro was verified as a good reader to analyse the TLD. (author)

  7. Environmental dosimetry system based on LiF : Mg, Ti (TLD-100)

    International Nuclear Information System (INIS)

    Saez Vergara, J.C.

    1990-01-01

    The report presents the various tests carried out to the characterize a thermoluminescence environmental dosimetry systems, using the phosphor LiF:mg,Ti (TLD-100) in chip form. The holder has been specifically designed in order to obtain simplicity in the operation and to assure correct measurements in terms of the new operational quantities in radiation protection (ICRU-1985). Some topics in TLD Environmental Monitoring are discussed (Dark Current, Reference Light, Zero Reading, Free-in-Air or Phantom Calibration, Fading Correction, Transit Dose, etc.), and the proposed solutions are exposed. The tests performed have been designed to conform with the different existing international Standards and Recommendations (ANSI : N545-1975; IEC: Draft 45B-1987, ISO : DP 8034-19849. The data from an European Interlaboratory Programm (EUR-8932) have been used to evaluate the performance : the TLD System presented is among the best systems using TLD-100. The results obtained in the characterization (linearity, repeatability, detection threshold, residue, angular response, stability of stored information, etc.) show the optimum performance of this dosimetric system in its application to environmental gamma dose monitoring. Based on these results, two operational procedures have been developed for the application of this Dosimetric System, specially in Quality Assurance Monitoring Programs around Nuclear Plants in Spain. (author)

  8. Indoor gamma radiation monitoring In Rawalpindi, Pakistan using TLD100

    International Nuclear Information System (INIS)

    Azam, Sana; Tufail, Muhammad; Sohail, Muhammad

    2008-01-01

    Full text: Natural radioactivity originates from extraterrestrial sources as well as from radioactive elements in earth's crust. The amount of radioactivity varies from place to place and with altitude. The aim of this study was to observe the indoor radiation level in Rawalpindi using TLD. For this purpose LiF:Mg:Ti (TLD100) chips were used. Chips were annealed and then calibrated using different sources and the calibration factor obtained by using Cs137 source was selected for dose estimation. Its value was 0.1403 μGy/TL response. Rawalpindi categorized into six regions. In each region, 5 cemented houses were selected and TLD 100 chips were placed at a distance of 0.5 m from ground the level. Chips were properly covered to protect them from ultraviolet light and moisture and were placed for three months. The average annual indoor dose rate for Rawalpindi was estimated to be 392.105μGy/yr and average dose to be 97.65μGy. Therefore, the effective dose for population of Rawalpindi from indoor gamma radiation was estimated to be 313.68μSv/yr using an indoor occupancy factor of 80%. (author)

  9. Performance analysis of the TNO TLD individual monitoring service

    International Nuclear Information System (INIS)

    Dijk, J.W.E. van; Julius, H.W.

    1990-01-01

    The purpose of this study was to analyse the performance and to establish the lowest detectable occupational dose (LDOD) of the TNO TL dosemeter, in use for large scale routine individual monitoring since 1983. The TNO individual monitoring service uses three TLD reader systems and over 45000 TL dosemeters, designed to measure H s (0.07) and H p (10). Each reader system is normalised daily and each individual dosemeter is calibrated every ten readout cycles. The performance of the service is monitored by a double blind experimental set-up. A series of 10 routine dosemeters is issued every fortnight, mailed, exposed by staff not involved in the monitoring service, sent back and evaluated. The conclusion of this study is that the lowest detectable occupational dose is less than 0.04 mSv and that the integrated dose at the level of the annual dose limit is measured within 2%. (author)

  10. Personnel photon dosimeter on the base of TLD sup n sup a sup t LiF

    CERN Document Server

    Kaskanov, G Y

    2003-01-01

    A personnel photon dosemeter on the basis of thermoluminescence detectors (TLD) sup n sup a sup t LiF is described. Experimental responses of the dosemeters in the unit of individual equivalent dose H sub p (10) for energy of photons 59.5, 120, 662, and 1250 keV are presented. It is shown that the dosemeter allows one to measure H sub p (10) with admissible uncertainty in the energy range from 60 to 1250 keV.

  11. Parallel analysis of film and TLD application in personal dosimetry of medical staff during application of invasive radiological procedures

    International Nuclear Information System (INIS)

    Misovic, M.; Boskovic, Z.; Spasic-Jokic, V.

    1997-01-01

    Although both types of dosimeters showed similar results for mentioned category of health care workers we wished to emphasize some advantages in use of TLD and film dosemeters in personal dosimetry. The main advantageous of film for dosimetric purposes are that it can provide visual representation of the radiation field and they are cheap, but there are lot of disadvantages. Advantages of TLD are based on: possibility for re-use, practically for whole users working life, small dimensions suitable for results, high precision and specially wide dose range. They are sensitive on low dose, practically for ten times more than film is. Disadvantages of TLD are based on their previous thermal and radiation history and on the fact that information about dose disappears after reading procedure. Considering advantages and disadvantages of both types of dosemeters we decided to propose TLD for routine hospital practice in personal dosimetry. (author)

  12. Measurement of high natural background radiation levels by TLD at Cox's Bazar coastal areas in Bangladesh

    International Nuclear Information System (INIS)

    Mollah, A.S.; Rahman, M.M.; Koddus, M.A.; Husain, S.R.; Malek, M.A.

    1987-01-01

    High natural background radiation levels at the Cox's Bazar coastal areas in Bangladesh were measured by LiF (TLD-100) dosemeters. The dose rates varied from 2621 to 35391 μGy.y -1 with a mean of 11968 μGy.y -1 . The average dose rate is found to significantly higher than the world average value. In order to formulate appropriate guidelines for radiation protection of the population in this area, the necessary recommendations are described. (author)

  13. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative magnitudes ICRU, for external fields of beta radiation. Part I. Study of the homogeneity of the response personal dosemeters leaves (cards G-1, TLD-100), in radiation fields of Co{sub 60}; Medicion de dosis equivalente con dosimetros personales e instrumentos de proteccion radiologica en las nuevas magnitudes operativas ICRU, para campos de radiacion beta externos. Parte I. Estudio de la homogeneidad de la respuesta dosimetros personales (tarjetas G-1, TLD-100), en campos de radiacion de Co{sub 60}

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1994-01-15

    A sample of 40 composed personal dosemeters by cards model: G-l, (each card is made up of two TLD-100 crystals encapsulated in teflon), Harshaw trademark; those personal dosemeters present a free window and another with a filter of A1 of 171.7 mg cm{sup -2} of mass thickness.The objective of the work is to select of this sample of 40 personal dosemeters a population with the same stocking and standard deviation. The technique used is that of comparison of stockings, (ANOVA; Variance Analysis, when samples of the same one were had size; and/or GLM, Widespread Lineal Models, when the samples were of different size), by means of the use of those Duncan statistics, SNK, Tukey, Gabriel; the results are validated proving the kindness of adjustment of the experimental data to a Normal distribution by means of the Shapiro-Wilks statistics.The experimental design used consists on a test of two vias: a via is the variable card with two levels, (crystal 1 and 2), the other via is the variable irradiation position with four levels, (LS=left superior, SR= right superior, LI= left Inferior, IR = right inferior). The irradiations carried out in blocks of four personal dosemeters in a gamma radiation beam range of Cobalt 60; carrying out three repetitions of the design. With object of proving the homogeneity of the filter of A1 in those personal dosemeters the experimental design was executed for those cards without personal dosemeters.They were also carried out tests of stockings to the readings of bottom and sensibility of the reader equipment, (Harshaw, model marks 2271), certain that doesn{sup t} exist differences for sequence of reading, but if in the stockings of the sensibility, (they were 4 different populations). The responses of the dosemeters were corrected subtracting him the reading correspondence of bottom and by sensibility of the reader equipment before subjecting them to the tests of stockings mentioned. Of the results of the tests of stockings for the cards with

  14. About the measurements systems with pen and thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Cortes I, M.E.; Ramirez G, F.P.

    1998-01-01

    In this work it is presented dosimetric data obtained with pen and thermoluminescent dosemeters, which are used by the Occupational Exposure Personnel (OEP) of the Mexican Petroleum Institute (IMP)(1). It was marked several great characteristics as for example, the differences among units which use one and another dosemeter type. Likewise, it is given to know diverse problems that were had in the IMP at relating the data obtained with these dosemeters (which utilizes OEP) and the ICRP 60 recommendations 1990. One of the most important difficulties is to satisfy the recommended limits by ICRP, particularly those that are referring to the units and their complex calculations. With respect to the unities, the ICRP makes reference at the concepts 'dose equivalent' and 'effective dose' with the sievert unit, that the General Regulations for Radiological Safety associates with 'dose equivalent' and 'effective dose equivalent'. It was illustrated the type of dosimetric statistics which are obtained with the TLD lectures and a OEP pen dosemeter during 1997. (Author)

  15. The design philosophy for an automatic TLD system to meet current international specifications

    International Nuclear Information System (INIS)

    Haaslahti, J.

    1986-01-01

    The object of this paper is to describe the elements of a new automatic TLD system intended to meet draft IEC/ISO proposals and ANSI requirements in the USA. Dosemeter badge design is based on ICRU recommendations. The basic intent has been to produce a standard system that can measure and file raw data that can be adapted to specific user requirements with software. The system consists of a programmable automatic reader, an automatic irradiator, a computer, and dosemeters for environmental, whole body, extremity, and clinical applications. The reader uses hot nitrogen heating and photon counting, and measurement conditions may be chosen with complete freedom. The reader can produce a real-time glow curve to assist in checking performance. The irradiator has a 90 Sr- 90 Y source to permit programmed irradiation for calibration and material sensitivity checks. Cassettes are used to hold TLD cards during processing. Cassette coding both identifies samples and calls measurement parameters into use from memory. The system can be preprogrammed to measure all common materials and all common dosemeter elements (both square and round). (author)

  16. Results and discussion of laboratory experiences with different automated TLD readers for personnel monitoring

    International Nuclear Information System (INIS)

    Regulla, D.F.; Drexeler, G.

    Although the film seems to continue serving as the main personnel dosemeter in Germany for the time in sight, the evolution of particularly solid state techniques and their properties are thoroughly considered with respect to a possible generalized application in personnel monitoring. For this reason different automated TLD systems that are commercially available have been investigated in the laboratory in order to find out their usefulness for a largescale or also decentralized service. Along with studying the dosimetrical and apparative parameters, the question has been discussed to which monitoring philosophy these TLD systems seem to fit. It is reported both on experimental experiences achieved as well as on the results of basic discussions that in return influence the discussion about the necessary outfit of personnel TL dosemeters

  17. Al2 O3:Cr,Ni: a possible thermoluminescent dosemeter

    International Nuclear Information System (INIS)

    Mariani R, Francisco; Roman B, Alvaro; Saavedra S, Renato; Ibarra S, Angel

    1996-01-01

    Results from a study on the thermoluminescent (Tl) emission from Al 2 O 3 :Cr,Ni are presented. The measurements were obtained for evaluation of the Al 2 O 3 :Cr,Ni dosimetric properties. Different crystal batches were exposed to two kind of ionizing radiation (X-ray and β - ). The Tl spectrum has a main peak with high thermal and optical stability, deviating from linearity for doses lower than 3.6 Gy. Furthermore, this material shows advantages (thermal resistance, reusability, multiple heating cycles) compared to TLD-100. Measured Al 2 O 3 :Cr,Ni properties indicate that it could be used as a dosemeter. (author)

  18. Determination of the TLD-100 physical parameters

    International Nuclear Information System (INIS)

    Paucar J, J.; Picon C, C.

    1998-01-01

    This study was realized in the Physics service at the Radiotherapy Department of the National Institute of Neoplasic Diseases in Lima, Peru, it was determined the activation energy, the kinetic order and the frequency factor of the fifth peak of the TLD-100 thermoluminescent spectra using different algorithms. This was carried out in parallel with the implementation and design of a software and an interface associated with the Tl lecturer which allows a semiautomatic control for a thermoluminescent lecturer process. (Author)

  19. Adequacy of annealing duration in reducing the background counts of personnel monitoring TLD cards - a study

    International Nuclear Information System (INIS)

    Srivastava, Kshama; Varadharajan, Geetha; Punekar, M.P.; Chougaokar, M.P.; Ayappan, P.

    2010-01-01

    In India, the personnel monitoring service of ∼ 70,000 radiation workers is being provided using indigenously developed TLD system comprising three CaSO 4 :Dy embedded Teflon discs. In order to remove TL and reset the distribution of defects/trapping centres, all TLD cards are subjected to an annealing treatment at elevated temperature prior to their next use. As per the standardized protocol annealing is carried out in a hot air circulating oven at 230 deg C for 4 hr, which is sufficient to reset the TL dosemeters for dose levels upto 100 mSv. In order to verify the appropriateness of annealing procedures adopted by the Laboratory, a detailed study was conducted using four sets of cards namely A, B, C and D series, exposed to various dose levels

  20. Test of an albedo neutron dosimetry system: TLD calibration and readout procedure, neutron calibration, dosimetry properties, routine application

    International Nuclear Information System (INIS)

    Piesch, E.; Burgkhardt, B.

    1988-03-01

    The two-component albedo dosemeter in use consists of an universal boron-loaded plastic encapsulation, the beta and albedo neutron windows of which are adopted to the corresponding TLD system of the manufacturers Alnor, Harshaw, Panasonic and Vinten. Beside the TLD detectors the capsule may contain also track etch detectors. Within a BMU project the system was investigated by four governmental measurement services in the FRG with respect to its qualification for personnel monitoring with emphasis in the readout and calibration procedures for the TLD system, the evaluation technique for the estimation of the photon and neutron dose equivalent in routine monitoring and the calibration of the personnel dosemeter in stray neutron fields. The test has shown the readiness of the system to act in the application areas of nuclear power reactors and linacs behind heavy shieldings, in the fuel element cycle, use of fissile materials, criticality, use of radionuclide sources, high energy particle accelerators. The uncertainty due to energy dependence was found to be within a factor of 2 for a single application area. In the case of irradiations from the front half space the dose equivalent H'(10) is indicated sufficiently independent of the direction of the radiation incidence. After completion of the test the albedo dosemeter became the official neutron personnel dosemeter in the FRG. It allows the separate estimation of the dose equivalent of hard beta radiation, photon radiation and neutrons. (orig./HP) [de

  1. Energy and angular dependence of the personal dosemeter in use at ITN-DPRSN

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Joao G. [Departamento de Proteccao Radiologica e Seguranca Nuclear, Instituto Tecnologico e Nuclear, EN 10, 2686-953 Sacavem (Portugal)], E-mail: jgalves@itn.pt; Calado, Ana M.; Cardoso, Joao V.; Santos, Luis M. [Departamento de Proteccao Radiologica e Seguranca Nuclear, Instituto Tecnologico e Nuclear, EN 10, 2686-953 Sacavem (Portugal)

    2008-02-15

    In this paper the characterization of the dosimetry system and of the personal dosemeter in terms of the stability of the reader calibration factors and of the linearity of the response for the 137Cs reference radiation is presented. The energy and angular dependence of the whole body dosemeter are also shown. The energy dependence was determined performing irradiations with the X-ray narrow series beams N30, N40, N60, N80, N100, N120 and with the gamma reference radiations of 137Cs and 60Co [ISO 4037-1, 1996. X and Gamma Reference Radiation for Calibrating Dosemeters and Doserate Meters and for Determining Their Response as a Function of Photon Energy-Part 1: Radiation Characteristics and Production Methods. International Organization for Standardization, Geneva] in terms of Hp(10) incident on the ISO water slab phantom. The angular dependence of the dosemeter was determined for the angles 0 deg., {+-}20 deg., {+-}40 deg. and {+-}60 deg. with normal using the above mentioned radiation fields. All irradiations were performed at the Laboratorio de Metrologia das Radiacoes lonizantes of ITN-DPRSN. The experiments presented in this paper show the thermoluminescence dosimetry (TLD) system is stable and presents a linear behaviour over and extended dose range. The measurements allowed the determination of the energy dependence at normal incidence and of the angular dependence of the dosemeter currently in use. Further studies are being carried out in order to implement correction factors for supralinearity and low energy measurements.

  2. Determination of kinetic parameters in Tl dosemeters of LiF: Mg, Cu, P + PTFE developed in the ININ; Determinacion de parametros cineticos en dosimetros Tl de LiF: Mg, Cu, P + PTFE desarrollados en el ININ

    Energy Technology Data Exchange (ETDEWEB)

    Basurto G, B.S

    2002-07-01

    The objective of this work, is the one of determining the kinetic parameters of the dosemeter of LiF: Mg, Cu, P + Ptfe; starting from the curves Tl obtained at being irradiated with alpha radiation ({alpha}), beta ({beta}) and gamma ({gamma}). As like to compare its sensitivity with each radiation type, considering the sensitivity of the TLD-100 as the unit. In the Chapter 1, the fundamental structure of the matter is described, making emphasis in the different radiation types, and their interaction with this. In the Chapter 2, the units are described but used in the dosimetry of the radiation. In the Chapter 3, the basic concepts of the phenomenon of Tl are described and those are explained characteristic of the deconvolution method to determine the kinetics of the one phenomenon. In the Chapter 4, the methodology is detailed that was used in the elaboration of this thesis work, describing the material Tl that were considered like reference, as well as the sources of ionizing radiation, with those that the dosemeters were irradiated and the equipment in the one that the curves Tl was obtained. Reference is made to the software used to carry out the deconvolution of the curves Tl that were obtained in the one experimental development. In the Chapter 5, the obtained results of this study are presented, showing the tables of homogenization of dosemeters and the reading of the same one; they are observed the curves Tl obtained to different radiation doses (alpha, beta and gamma), the intensity Tl in function of the dose. Also they are tabulated, the obtained results in the kinetic parameters of the three different study materials (TLD-100H, USA; TLD-100, USA and LiF: Mg, Cu, P + Ptfe developed in the l.N.l.N). They are analyzed shortly for each material Tl their sensitivity to the ionizing radiation as well as their kinetic parameters. The obtained results showed that the Tl dosemeters of LiF: Mg,Cu,P + Ptfe, they presented a bigger sensitivity that the TLD-100 when

  3. Tl response of LiF: Mg, Cu, P+Ptfe at X rays of 24, 42 and 100 KeV; Respuesta TL de LiF: Mg, Cu, P+Ptfe a rayos X de 24, 42 y 100 KeV

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, P.R.; Tovar M, V.M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Azorin N, J. [UAM-I, 09340 Mexico D.F. (Mexico); Furetta, C. [Universita degli Studi di Roma ' La Sapienza' , Piazzale Aldo Moro 2, 00185 Roma (Italy); Quiroz C, M.C. [Facultad de Medicina, UAEM, 50180 Toluca, Estado de Mexico (Mexico)

    2005-07-01

    In this work the obtained results of the irradiation of thermoluminescent dosemeters (Tl) of LiF: Mg,Cu,P + Ptfe with X rays for the effective radiation energy of 24, 42 and 100 keV, in an interval of Kerma in air in the sinus of the air between 0.05 and 1.0 Gy are presented. The rate of Kerma in air was determined with an ionization chamber PTW-1152, gauged by the Laboratoire Central des Industries Electriques (LCIE). As reference commercial TLD-100 dosemeters was used. The results showed that the studied Tl dosemeters presented a lineal response in the interval of mentioned Kerma. On the other hand the estimated Kerma with the Tl dosemeter in the calibration curves for X rays, were similar to the one measured with the previously gauged ionization chamber. The Tl of LiF: Mg, Cu, P + Ptfe, developed in the ININ, are highly reliable for X-ray dosimetry. (Author)

  4. Dosimetric evaluation of the response of the TLD-100 dosemeters in the IMRT technique by 'Step and Shoot'; Evaluacion dosimetrica de la respuesta de los dosimetros TLD-100 en la tecnica de IMRT por 'Step and Shoot'

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, J. [Fundacion Clinica Valle del Lili, A.A. 020338, Cali (Colombia); Benavides, S.O. [Depto. de Fisica, Universidad del Valle, A.A. 25360, Cali (Colombia)

    2005-07-01

    We show the results of the dosimetry response of LiF thermoluminescent crystals: TLD-100, where they were radiated in a linear accelerator Siemens Primus Hl using the Intensity Modulated Radiation Therapy (IMRT) by step and shoot technique. Previous to the crystals calibration and response evaluation, the acceptation procedures recommended by the TG-53 protocol for validation of the technique were carried out. The planning system utilized was the Theraplan Plus 3.8, using the algorithm of Pencil Kernel. The register and verification system was Lantis 5.2. The response curve of dose versus charge was obtained from the readings of the TLD in a Harshaw 3500. The crystals were radiated in a Bench- Marck phantom with doses previously determined by using ionization chambers for square radiation fields, in a beam with a 0.68 TPR20,10 corresponding to 6 MV of energy. We compare the response of these through of radiation of segmented fields in a Anthropomorphic phantom and the calculated doses by the planning system. The results obtained in the crystals response show deviations less than 5 % between the measured dose and the calculated dose in the zones of low gradient. It allows its implementation like routine control of quality by IMRT. (Author)

  5. Hand book on the use of TLD badge based on CaSO4:Dy teflon TLD discs for individual monitoring

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Adtani, M.M.; Varadharajan, G.; Bakshi, A.K.; Srivastava, Kshama; Bihari, R.R.

    2002-10-01

    Individual monitoring is one of the most important aspects of a radiation protection programme. In India, an official and centralized personnel monitoring service to radiation workers started in 1952. With the indigenous development of a TLD badge system in 1975 at Bhabha Atomic Research Centre, decentralization of monitoring service was initiated. At present, about 40,000 radiation workers are monitored using this system through twelve TLD units located in different parts of the country, including a private accredited laboratory. Regulatory and other inspecting bodies have often asked outstation TLD units to produce a duly approved document on the procedures being practiced for the assessment of personal doses. A need for such a document has also been felt to ensure the uniformity in processing of dosemeters, recording and reporting of doses by different TLD units and to provide guidelines regarding the infrastructure requirement. This document in the form of a handbook has been prepared to cater to the above needs. The handbook is expected to provide necessary guidelines not only to the newcomers/ forthcoming units and the existing laboratories but also to help the regulators, inspectors and assessors. (author)

  6. State of the art in thermoluminescent dosimetry using dosemeters with automated read-out

    International Nuclear Information System (INIS)

    Regulla, D.F.

    1979-01-01

    In the beginning, the results obtained with automated read-out TLD have been quite disappointing, both for manufacturers and users. In response to this, industry then seeked advice and assistance from those experienced in the practical use of dosemeters, and the development of the second generation of automated TLD has been a common task of manufacturers and purchosers. As a preliminary achievement of development work along this line, a dosemeter has been presented by a Japanese manufacturer, meeting the requirements in quite a satisfactory way. The device is characterized by a frequency of disturbance of -5 , a microprocessor for controlling the measuring and control functions, possibility of active input of device parameters and boundary conditions, extensive self-control of operating functions, complete data protection, and thin-film detector technique. Pursuing this line of development, and taking into account future recommentations, automated thermoluminescent dosimetry does seem to be a promising alternative to current measuring techniques in personnel monitoring. (orig./RW) [de

  7. Calibration of personal dosemeters in terms of the ICRU operational quantities

    International Nuclear Information System (INIS)

    McDonald, J.C.; Hertel, N.E.

    1992-05-01

    The International Commission on Radiological Units and Measurements (ICRU) has defined several new operational quantities for radiation protection purposes. The quantities to be used for personal monitoring are defined at depths in the human body. Because these quantities are impossible to measure directly, the ICRU has recommended that personal dosemeters should be calibrated under simplified conditions on an appropriate phantom, such as the ICRU sphere. The US personal dosimetry accreditation programs make use of a 30 x 30 x 15 cm polymethymethacrylate (PMMA) phantom, therefore it is necessary to relate the response of dosemeters calibrated on this phantom to the ICRU operational quantities. Calculations of the conversion factors to compute dosemeter response in terms of the operational quantities have been performed using the code MCNP. These calculations have also been compared to experimental measurements using thermoluminescent (TLD) detectors

  8. Elaboration And Study Of Transfer Alanine/ESR Dosemeters

    International Nuclear Information System (INIS)

    Torres G, Luz A.

    1996-01-01

    The dosimetry is the dose measure imparted by the energy from the ionizing radiation to the matter. The dosemeters is the means used for the determination of such a dose. Diverse dosimetric classes exist, this classification depends in essence of the energy involved in the irradiation process and of its application necessity. It is as well as in radiological protection movie dosemeter is used, and TLD, in the calibration of units, as those of cobalt, the ionization cameras are used, in the detection of superficial contamination the accountants Geiger Muller and proportional etc. The transfer dosimeter Alanine/ESR is used, object of the present work, is characterized because after reading the registered dose, the information is conserved and it can be transferred and read in any team of ESR. Likewise the following dose that is imparted will be added to the previous one registered, this indicates that the dosemeters is of integral character. In the spectra taken ESR, it is determined that the integral double or area under the curve of the spectrum ESR is proportional to the concentration of free radicals generated by the radiation ionization and in turn this concentration is proportional to the dose received by the pills; in last, these proportionality relationships take to that the area under the curve of the spectrum main ESR is proportional to the radiation dose received by the alanine dosemeters. This dosemeter seeks to be an economic alternative that it will lend the calibration service that today offers the ionization Cameras or the acrylic red industrial dosemeters

  9. Australian participation in international intercomparisons of environmental dosemeters

    International Nuclear Information System (INIS)

    Boas, J.F.; David, R.C.; Jones, J.

    2002-01-01

    The Environmental Measurements Laboratory of the U.S. Department of Energy has conducted international intercomparisons of environmental dosemeters at regular intervals since 1974. This paper reports the results obtained in the 10th and 11th intercomparisons by JFB and JGY at the Australian Radiation Laboratory (in 1992 and 1996 respectively) and in the 12th intercomparison by JFB and DRCT at the Australian Radiation Protection and Nuclear Safety Agency and by JGY and JJ at Australian Radiation Serviceces during 2000 and 2001. The ARL/ARPANSA measurements used a simple dosemeter holder containing two CaSO 4 :Dy impregnated Teflon discs, one unshielded and the other shielded by approximately 2.4 mm of Cu. The ARS measurements used a commercially available TLD badge case containing a CaSO 4 :Dy impregnated Teflon card. The commercial badge case was not symmetrical in design. The filtration in the front and rear sections of the commercial badge case varied from an open area to an area shielded by copper, tin and cadmium. The results obtained were generally within ±15% of the reference values measured by EML using high-pressure ionisation chambers for dosemeters exposed hi the field to environmental radiation and for dosemeters given a single exposure to 137 Cs or 241 Am at EML or an associated laboratory. Similar agreement was obtained for dosemeters exposed in the field and also given a single exposure to 137 Cs radiation. In order to obtain this measure of agreement, the dosemeters were individually calibrated and the readouts corrected for fading. Copyright (2002) Australasian Radiation Protection Society Inc

  10. Verification or treatment planning system of radiotherapy using TLD-100; Verificacion de los sistemas de planificacion de tratamiento de radioterapia empleando TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Pinuela, J., E-mail: jcpinuela@hotmail.co [Hospital Central de Maracay (Venezuela, Bolivarian Republic of). Servicio de Radioterapia

    2010-07-01

    The evaluation of the treatment planning system (TPS) used in radiotherapy Precise Plan, was carried out using TLD-100 dosimeters, comparing the dose obtained with an ionization chamber. The TLD-100 were calibrated using secondary standard of SSDL, selecting dosimeters which had a standard deviation less than 1% for dosimeter calibration and less than 5% for dosimeter of field, for the tests conducted in TPS, The Alderson Phantom was used to evaluate the wedge and bolus, and Lucy 3D allowed us to evaluate correspondence of CT numbers, volume expansion, beam shaping, precise dose and beam weigh assignment. It was observed that the results of Lucy 3D were within the values expected except the volume expansion process with more than 10% difference, the evaluation of beam modulators systems with wedges and bolus as beam shaping yielded values within the expected with variations less than 5% and to assess the supply of specific doses, it was observed that the values obtained were precise and accurate since the same variation was less than 0.5% for the test. The importance of assessing the TPS lies in our country there is no procedure to verify that system and these tests provide a basis for future comparisons. (author)

  11. Tl response of LiF: Mg, Cu, P+Ptfe at X rays of 24, 42 and 100 KeV

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.; Tovar M, V.M.; Azorin N, J.; Furetta, C.; Quiroz C, M.C.

    2005-01-01

    In this work the obtained results of the irradiation of thermoluminescent dosemeters (Tl) of LiF: Mg,Cu,P + Ptfe with X rays for the effective radiation energy of 24, 42 and 100 keV, in an interval of Kerma in air in the sinus of the air between 0.05 and 1.0 Gy are presented. The rate of Kerma in air was determined with an ionization chamber PTW-1152, gauged by the Laboratoire Central des Industries Electriques (LCIE). As reference commercial TLD-100 dosemeters was used. The results showed that the studied Tl dosemeters presented a lineal response in the interval of mentioned Kerma. On the other hand the estimated Kerma with the Tl dosemeter in the calibration curves for X rays, were similar to the one measured with the previously gauged ionization chamber. The Tl of LiF: Mg, Cu, P + Ptfe, developed in the ININ, are highly reliable for X-ray dosimetry. (Author)

  12. TLD audit in radiotherapy in the Czech Republic

    International Nuclear Information System (INIS)

    Kroutilikova, D.; Zackova, H.; Judas, L.

    1998-01-01

    National Radiation Protection Institute in Prague organizes the TLD audit. The aim of the TLD postal audit is to provide control of the clinical dosimetry in the Czech Republic for purposes of state supervision in radiotherapy, to investigate and to reduce uncertainties involved in the measurements of absorbed dose and to improve consistency in dose determination in the regional radiotherapy centers. TLD audit covers absorbed dose measurements under reference conditions for 60 Co and 137 Cs beams, high-energy X-ray and electron beams of of linear accelerators and betatrons. The thermo-luminescence dosemeters are sent regularly to all radiotherapy centers. Absorbed dose measures by the TLD is compared to absorbed dose stated by radiotherapy center. Encapsulated LiF:Mg, Ti powder is used for the measurement. Deviation of 3% between stated and TLD measured dose is considered for photons and ±5% for electron beams. First TLD audit was started in 1997. A total of 135 beams was checked. There were found seven major deviations (more than ±6%), which were very carefully investigated. Medical Physicists from these departments reported a set-up mistake. However, at most of those hospitals with major deviations, an in situ audit in details was made soon after TLD audit. There were found discrepancies of clinical dosimetry but also bad technical state of some of the irradiation units. In 1998, second course TLD audit was started. No major deviation was found. Regular TLD audit seems to be a good way to eliminate big mistakes in the basic clinical dosimetry. Repeated audit in the regional radiotherapy centers that had major deviation during the first audit exhibited improvement of their dosimetry. It is intended to broaden the method and to control also beam parameters by means of a multi-purpose phantom. (authors)

  13. Calibration of personal dosemeters for extremities of fields of radiation gamma

    International Nuclear Information System (INIS)

    Papadopulos, S.; Gregori, S.; Moreno, B.; Guillen, J.

    1998-01-01

    In this work the conversion factors are presented obtained experimentally of kerma in free air in equivalent dose H(d,O o ) in finger and in arm for fields of radiation gamma of normal incidence dosemeters of extremities was irradiated, based on detecting TL of LIF 7 (TLD-700, Harshaw), placed on the surface of the finger phantom and arm

  14. Automated TLD systems: what can we expect from the market today?

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Strachotinsky, Ch.

    1990-01-01

    The personnel monitoring service at the Austrian Research Centre Seibersdorf, which presently handles some 16,000 dosemeters per month, has been operating for more than ten years with three automated TLD systems, Harshaw model 2271. In order to renew the instrumentation an extensive evaluation and comparison of four commercially available automated systems designed to the present state-of-the-art has been carried out. The test procedures included dosimetric performance, reliability, handling speed and throughput, and additional information such as glow curve evaluation etc. The results should provide useful advice to monitoring services interested in the application of modern automated TLD systems currently on the market. (author)

  15. Quality control of the breast cancer treatments on Hdr brachytherapy with TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Torres H, F. [Universidad de Cordoba, Materials and Applied Physics Group, 230002 Monteria, Cordoba (Colombia); De la Espriella V, N. [Universidad de Cordoba, Grupo Avanzado de Materiales y Sistemas Complejos, 230002 Monteria, Cordoba (Colombia); Sanchez C, A., E-mail: franciscotorreshoyos@yahoo.com [Universidad de Cordoba, Departamento de Enfermeria, 230002 Monteria, Cordoba (Colombia)

    2014-07-01

    An anthropomorphic Phantom, a female trunk, was built with a natural bone structure and experimental material coated, glycerin and water-based material called JJT to build soft tissue equivalent to the muscle of human tissue, and a polymer (styrofoam) to build the lung as critical organ to simulate the treatment of breast cancer, with high dose rate brachytherapy (Hdr) and sources of Ir-192. The treatments were planned and calculated for the critical organ: Lung, and injury of 2 cm in diameter in breast with Micro Selectron Hdr system and the software Plato Brachytherapy V 14.1 of the Nucletron (Netherlands) which uses the standard protocol of radiotherapy for brachytherapy treatments. The dose experimentally measured with dosimeters TLD-100 LiF: Mg; Ti, which were previously calibrated, were placed in the same positions and bodies mentioned above, with less than 5% uncertainty. The reading dosimeters was carried out in a Harshaw TLD 4500. The results obtained for calculated treatments, using the standard simulator, and the experimental with TLD-100, show a high concordance, as they are on average a ± 1.1% making process becomes in a quality control of this type of treatments. (Author)

  16. Field calibration of a TLD albedo dosemeter in the high-energy neutron field of CERF

    International Nuclear Information System (INIS)

    Haninger, T.; Kleinau, P.; Haninger, S.

    2017-01-01

    The new albedo dosemeter-type AWST-TL-GD 04 has been calibrated in the CERF neutron field (CERN-EU high-energy Reference Field). This type of albedo dosemeter is based on thermoluminescent detectors (TLDs) and used by the individual monitoring service of the Helmholtz Zentrum Muenchen (AWST) since 2015 for monitoring persons, who are exposed occupationally against photon and neutron radiation. The motivation for this experiment was to gain a field specific neutron correction factor N n for workplaces at high-energy particle accelerators. N n is a dimensionless factor relative to a basic detector calibration with 137 Cs and is used to calculate the personal neutron dose in terms of H p (10) from the neutron albedo signal. The results show that the sensitivity of the albedo dosemeter for this specific neutron field is not significantly lower as for fast neutrons of a radionuclide source like 252 Cf. The neutron correction factor varies between 0.73 and 1.16 with a midrange value of 0.94. The albedo dosemeter is therefore appropriate to monitor persons, which are exposed at high-energy particle accelerators. (authors)

  17. Use of MCNP to compare the response of dose deposited in the TLD 100, TLD 600 and TLD 700 in radiation fields due to {sup 60}Co and {sup 241}AmBe source; Uso do MCNP para comparacao das respostas de dose depositada nos TLD 100, TLD 600 e TLD 700 em campos de irradiacao devido a fontes de {sup 60}Co e {sup 241}AmBe

    Energy Technology Data Exchange (ETDEWEB)

    Cavalieri, Tassio A.; Castro, Vinicius A.; Siqueira, Paulo T.D., E-mail: tassio.cavalieri@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2012-08-15

    The successes of Boron Neutron Capture Therapy (BNCT) depend on the ability to deliver an adequate irradiation field to the target cells. Neutron beams used in BNCT are mostly driven from reactors and therefore, not only have a neutron energy range which far exceeds the thermal region but also do have a great gamma component. Beam characterization and dosimetry are consequently one of the essential procedures to be overcome to properly apply this technique. One of the methods currently used in mixed field (field containing both neutron and gamma) characterization, lies on the use of a pair of detectors with distinct responses to each beam component. But this technique needs to be better understood of how each thermoluminescent dosimeter (TLD) behaves in a mixed field or in a pure field. This work presents the results of a set of simulations performed in order to analyze the response of three ordinary types of TLDs - TLD 100, TLD 600 and TLD 700 - submitted to different irradiation fields from a Cobalt source and an Americium-Beryllium source inside a paraffin disk. And is also a possible method for performing the selection and calibration of theses TLDs. (author)

  18. Comparative study of trapping parameters of LiF(TLD-100) from different production batches

    Energy Technology Data Exchange (ETDEWEB)

    Bos, A.J.J.; Piters, T.M.; Vries, W. de; Hoogenboom, J.E. (Delft Univ. of Technology (Netherlands). Interfaculty Reactor Institute)

    1990-01-01

    Computerised glow curve analysis has been used to determine the trapping parameters of the main peaks of the thermoluminescent (TL) material LiF(TLD-100). The TL material (solid state chips) originated from six different production batches with at least 19 chips per batch. The maxima of glow peaks 2 to 5 are found at the same temperature within very small limits. The activation energy and frequency factor of the main glow peak (peak 5) of TLD-100 originating from two batches differ significantly from those of the other four investigated batches. Nevertheless, the sensitivity of glow peak 5 is more or less the same for all batches. The trapping parameters of glow peaks 2 to 4 of TLD-100 vary little from batch to batch. The measured half-life of peak 2 differed strongly from batch to batch. For all investigated peaks no correlation has been found between glow peak sensitivity and trapping parameters. The results of this study suggest that both defect concentration and nature of the trapping centres vary from batch to batch. It would appear that as a consequence of selection by the manufacturer, the differences between the batches in terms of total light output are small. (author).

  19. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P Thermoluminescent Dosemeter and its applications in diagnostic radiology - a review

    International Nuclear Information System (INIS)

    Fung, K.L.

    2004-01-01

    This study investigated the dosimetric properties of the high sensitivity TLD (Thermoluminescent Dosemeter) of LiF:Mg,Cu,P and its applications in diagnostic radiology. A reproducible readout and annealing regime for this high sensitivity TLD was developed in the initial part of this study with the newly installed automatic TLD Reader system. Basic dosimetric characteristics of this T.L. dosemeter were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom. The applications studied in radiological procedures included: dose reduction in lumbar spine radiography utilizing the 'anode heel effect'; gonad dose variation with kV p in chest radiography; foetal dose comparison between computed tomography (CT) and computed radiography (CR) in X-ray pelvimetry; lens dose reduction with bismuth eye-shields in CT brain studies; foetal dose assessment of early pregnancy in common high risk radiological examinations. It is anticipated that the unique and favourable dosimetric performance of LiF:Mg,Cu,P T.L. phosphor will be exploited further in measurements of low level dose received by patients and staff in diagnostic radiological procedures such as paediatric X-ray examinations

  20. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P Thermoluminescent Dosemeter and its applications in diagnostic radiology - a review

    Energy Technology Data Exchange (ETDEWEB)

    Fung, K.L. E-mail: orkarl@polyu.edu.hk

    2004-05-01

    This study investigated the dosimetric properties of the high sensitivity TLD (Thermoluminescent Dosemeter) of LiF:Mg,Cu,P and its applications in diagnostic radiology. A reproducible readout and annealing regime for this high sensitivity TLD was developed in the initial part of this study with the newly installed automatic TLD Reader system. Basic dosimetric characteristics of this T.L. dosemeter were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom. The applications studied in radiological procedures included: dose reduction in lumbar spine radiography utilizing the 'anode heel effect'; gonad dose variation with kV{sub p} in chest radiography; foetal dose comparison between computed tomography (CT) and computed radiography (CR) in X-ray pelvimetry; lens dose reduction with bismuth eye-shields in CT brain studies; foetal dose assessment of early pregnancy in common high risk radiological examinations. It is anticipated that the unique and favourable dosimetric performance of LiF:Mg,Cu,P T.L. phosphor will be exploited further in measurements of low level dose received by patients and staff in diagnostic radiological procedures such as paediatric X-ray examinations.

  1. Development of CaSO4:Dy based ring dosemeter for extremity monitoring of radiation workers in India

    International Nuclear Information System (INIS)

    Srivastava, Kshama; Meenal, P.; Bhagat, R.V.; Singh, R.; Kolambe, D.H.; Chougaonkar, M.P.; Sapra, B.K.

    2014-01-01

    Extremity dosemeters are required to be worn in cases where the dose to extremities is expected to be significantly greater than the dose to the whole body. In India, CaSO 4 :Dy based three element personnel monitoring TLD badge worn at chest and wrist level are used for whole body and extremity monitoring, respectively. Presently no official/legal finger dosemeter is available for extremity monitoring for radiation workers in the country. To cater to the long standing requirement of finger dosimeter, a new compact three-element Extremity Ring Badge Dosemeter (ERBD) has been developed for measurement of the equivalent doses received by the extremities of radiation workers in terms of operational quantity Hp(0.07). It was aimed to meet the performance requirement of IEC/ISO standards. This paper gives the design detail and result of experimental studies of ERB dosemeter

  2. Evaluation of LiF:Mg,Ti (TLD-100 for Intraoperative Electron Radiation Therapy Quality Assurance.

    Directory of Open Access Journals (Sweden)

    Raffaele Liuzzi

    Full Text Available Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs response to intraoperative electron radiation therapy (IOERT beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2-12 cGy/pulse during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for quality assurance. The TLDs feature many advantages such as a small detector size and close tissue equivalence that make them attractive for IOERT as in vivo dosimeters.LiF:Mg,Ti dosimeters (TLD-100 were irradiated with different IOERT electron beam energies (5, 7 and 9 MeV and with a 6 MV conventional photon beam. For each energy, the TLDs were irradiated in the dose range of 0-10 Gy in step of 2 Gy. Regression analysis was performed to establish the response variation of thermoluminescent signals with dose and energy.The TLD-100 dose-response curves were obtained. In the dose range of 0-10 Gy, the calibration curve was confirmed to be linear for the conventional photon beam. In the same dose region, the quadratic model performs better than the linear model when high dose-per-pulse electron beams were used (F test; p<0.05.This study demonstrates that the TLD dose response, for doses ≤10 Gy, has a parabolic behavior in high dose-per-pulse electron beams. TLD-100 can be useful detectors for IOERT patient dosimetry if a proper calibration is provided.

  3. Development of quality assurance procedures for thermoluminescent CaSO sub 4 :Dy-teflon skived tape dosemeter

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, J.S.; Popli, K.L.; Kher, R.K.; Varadharajan, G. (Bhabha Atomic Research Centre, Bombay (India). Div. of Radiological Protection)

    1992-01-01

    CaSO{sub 4}:Dy-Teflon TLD dosemeter material has been manufactured locally in a 0.4 mm thick continuous tape form. Fourteen batches have been examined for physical thickness, density, spectral transmission, diffuse optical density, beta transmission and TL output per unit area for evolving a procedure for quality assurance of the TLD element for large scale production. With the exception of two batches, the TL output per unit area of the tape for a number of batches lies within {+-}7% of that for a standard batch. (author).

  4. Individual TL detector characteristics in automated processing of personnel dosemeters: correction factors as extension to identity codes of dosemeter cards

    International Nuclear Information System (INIS)

    Toivonen, Matti.

    1979-07-01

    One, two and three-component dosemeter cards and their associated processing equipment were developed for personnel monitoring. A novel feature of the TLD system is that the individual sensitivity correction factors of TL detectors for β/γ radiation dosimetry and special timing factors for the readout of neutron detectors are stored on dosemeter cards as an extension of the identity codes. These data are utilized in the automatic TL reading process with the aim of cancelling out the influence of the individual detector characteristics on the measuring results. Stimulation of TL is done with hot nitrogen without removing the detectors from their cards and without any metal contact. Changes in detector characteristics are thus improbable. The reading process can be adjusted in a variety of ways. For example, each detector in the same card can be processed with optimal heating and the specific 250 deg C glow peak of neutron radiation can be roughly separated from the main LiF glow peaks. (author)

  5. Photon beam audits for radiation therapy clinics: A pilot mailed dosemeter study in Turkey

    International Nuclear Information System (INIS)

    Yegingil, Z.; DeWerd, L. A.; Davis, S. D.; Hammer, C.; Kunugi, K.

    2012-01-01

    A thermoluminescent dosemeter (TLD) mailed dose audit programme was performed at five radiotherapy clinics in Turkey. The intercomparison was organised by the Univ. of Wisconsin Radiation Calibration Laboratory (UWRCL), which was responsible for the technical aspects of the study including reference irradiations, distribution, collection and evaluation. The purpose of these audits was to perform an independent dosimetry check of the radiation beams using TLDs sent by mail. Acrylic holders, each with five TLD chips inside and instructions for their irradiation to specified absorbed dose to water of 2 Gy, were mailed to all participating clinics. TLD irradiations were performed with a 6 MV linear accelerator and 60 Co photon beams. The deviations from the TL readings of UWRCL were calculated. Discrepancies inside the limits of ±5 % between the participant-stated dose, and the TLD-measured dose were considered acceptable. One out of 10 beams checked was outside this limit, with a difference of 5.8 %. (authors)

  6. Radiological environmental monitoring with LiF-700-H dosemeters

    International Nuclear Information System (INIS)

    Scarnichia, E.; Levanon, I.; Andres, P.; Miani, C.; Ramirez, S.

    2011-10-01

    Since 2008 a radiological environmental monitoring with LiF-700-H has been carried out as a result of increasing the Ra-6 research reactor core power. The information obtained is used to evaluate and to quantify analytically the air kerma rate, the fading and the associated uncertainty by developing software tools (deconvolution and uncertainty algorithms). LiF-700-H dosemeters were chosen because of their high sensitivity to low air kerma rates. They show a very good stability and a negligible fading for two-month working periods. The air kerma rate detection limit (based on the 3σ criterion) during these working periods is about 0.4 n Gy/h. Air kerma rates of about 70 n Gy/h are measured with this detection limit. Following the Nist guidelines, an algorithm was developed in order to find the associated uncertainty. It considers several aspects, such as the source activity decay, distance source-dosemeter during the calibration procedure, irradiation time, calibration factor, dosemeter readout, dosemeter sensitivity, TLD reader stability and fading. The associated uncertainty is found to be about 25% for a 95% confidence interval (k = 2.025), which can be considered acceptable when taking into account the very low air kerma rates estimated. The LiF-700-H response to different energies and its relationship with climate changes over the calendar year are planned as future tasks. (Author)

  7. Results of the IAEA/RCA personal dosemeter intercomparison

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Norio; Momose, Takumaro; Hayashi, Naomi [Environment and Safety Division, Tokai Works, Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan)

    2000-06-01

    The intercomparison of personal dosemeters for photon was carried out between 1990 and 1996 as part of the IAEA/RCA 'strengthening of radiation protection infrastructure' project. Japan Nuclear Cycle Development Institute participated in the intercomparison as one of the in-house personal dosimetry service organizations in Japan and also served the host irradiating laboratory. This report summarizes the dose evaluation results obtained from the JNC-TLD badges in the past four intercomparison programs. In the latest intercomparison the evaluated doses agreed to the reference doses with an accuracy of 10%. (author)

  8. Thermoluminescent dosemeter in a X-ray diffractometer; Dosimetria termoluminiscente en un difractometro de rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza A, D.; Gonzalez M, P.; Falcon B, T. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, Mexico D.F. (Mexico); Castano, V.M. [Instituto de Fisica, UNAM, Laboratorio Juriquilla, A.P. 1-1010, C.P. 76001, Queretaro (Mexico)

    1999-07-01

    In this work it was presented the results obtained of the dosimetry which was realized in a X-ray diffractometer for powders, trademark Siemens D5000, using the thermoluminescent signal generated by the X-rays in the commercial dosemeter TLD-100 of Harshaw, US. In according to the results obtained, the radiation quantity received by an analysed material in the diffractometer, will be proportional to exposure time and it can vary from unities until tenths of grays. These results are very outstanding when are analysed crystalline materials in a diffractometer, for knowing the present crystalline phases, mainly if these are highly sensitive to the ionizing radiation, as it is the case of the thermoluminescent materials. (Author)

  9. Summary of personal neutron dosemeter results obtained within the EVIDOS project

    International Nuclear Information System (INIS)

    Luszik-Bhadra, M.; Reginatto, M.; Schuhmacher, H.; Bolognese-Milsztajn, T.; Lacoste, V.; Boschung, M.; Fiechtner, A.; Coeck, M.; Vanhavere, F.; Curzio, G.; Errico d', F.; Kylloenen, J.-E.; Lindborg, L.; Bartlett, D.; Tanner, R.

    2005-01-01

    Full text: Within the EC project EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'), different types of neutron personal dosemeters were irradiated in workplace fields in nuclear installations in Europe. Mostly electronic personal neutron dosemeters were tested, among them commercial devices (Thermo Electron EPD-N, Aloka PDM-313), devices from first industrial prototype series (Thermo Electron EPD-N2, Saphydose-n) and laboratory prototypes which were already in the stage of lightweight battery-operated instruments (PTB DOS-2002). In addition, dosemeters with (almost) immediate readout (BTI bubble detectors, Rados DIS-N) and passive dosemeters which needed no fielddependent calibration factors (PADC track detectors from PSI and NRPB) were used, as well as those TLD albedo dosemeters which are routinely used in the facilities visited. The results of measurements obtained within the EVIDOS project in workplace fields in nuclear installations in Europe, i.e. at Kruemmel (boiling water reactor, transport cask), at Mol (Venus research reactor, fuel facility Belgonucleaire) and at Ringhals (pressurized water reactor, transport cask) are presented and compared to reference values of personal dose equivalent H p (10) determined by means of Bonner spheres and novel directional spectrometers. In fields with strong back-scatter and moderation of neutrons, several dosemeters showed overreadings by more than a factor of two. In strongly directed fields with neutron dose equivalent peaked at about 1 MeV (MOX fuel), the same dosemeters showed under-readings of about a factor of two. These under- and over-readings in the workplace fields can be explained in terms of the dosemeter response functions for mono-energetic neutrons, which show over-responses in the thermal and intermediate neutron energy region and under-responses at about 1 MeV neutron energy. The dosemeter readings obtained in the workplace fields were checked for consistency by

  10. TLD-100 glow-curve deconvolution for the evaluation of the thermal stress and radiation damage effects

    CERN Document Server

    Sabini, M G; Cuttone, G; Guasti, A; Mazzocchi, S; Raffaele, L

    2002-01-01

    In this work, the dose response of TLD-100 dosimeters has been studied in a 62 MeV clinical proton beams. The signal versus dose curve has been compared with the one measured in a sup 6 sup 0 Co beam. Different experiments have been performed in order to observe the thermal stress and the radiation damage effects on the detector sensitivity. A LET dependence of the TL response has been observed. In order to get a physical interpretation of these effects, a computerised glow-curve deconvolution has been employed. The results of all the performed experiments and deconvolutions are extensively reported, and the TLD-100 possible fields of application in the clinical proton dosimetry are discussed.

  11. Performance tests of a CaSO4:Dy based thermoluminescence personal dosemeter

    International Nuclear Information System (INIS)

    Azorin, J.; Gutierrez, A.; Niewiadomski, T.

    1986-01-01

    In order to replace LiF commercial thermoluminescence dosemeters (TLDs) now used in personnel monitoring, we developed a TLD personnel monitoring badge based on pellets of CaSO 4 :Dy bound in pure KBr placed in plastic holders provided with 0.8 mm Pb filters to compensate for the energy dependence of CaSO 4 :Dy. Performance tests, based on the proposals of international standards for TLDs intended to be used as general deep tissue personal dosemeters, were done by developing the detailed test methods both for the tests required by the International Atomic Energy Agency (fading, linearity, effect of fluorescent light and sunlight and stability under standard climatic conditions) and to meet the requirements of the International Electrotechnical Commission (batch homogeneity, detection threshold, stability of zero point repeatibility and residual). Initial tests showed a high residual and an increase of inhomogeneity. However, these drawbacks were overcome by changing the annealing procedure and the readout conditions. Using these new conditions TLDs met all the requirements for personal dosemeters. (author)

  12. The fast neutron response of 7LiF thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Knipe, A.D.

    1990-02-01

    A series of experiments was performed in 1982 to determine the neutron energy response of the 7 LiF thermoluminescent dosemeter (TLD) employed in European zero power fast reactor gamma-ray energy deposition studies. Preliminary results of this work were included in a 1985 International experimental data-base of TLD neutron sensitivities and provided the most consistent set of data within the 7 LiF compilation. A more detailed interpretation of these data has improved the results still further, giving a mean relative neutron to gamma efficiency of 0.118±0.005. The main objective of this re-evaluation was to establish recommended neutron energy response values to replace a 1974 data set for the analysis of in-core fast reactor measurements. This was achieved by combining the mean experimental relative efficiency of 0.118 with calculated energy dependent kerma factors. The kerma factors for the TLD were based on US National Bureau of Standards values and a composition determined by chemical analysis. Adoption of the revised neutron energy response data set produces a small increase in the measured gamma-ray energy deposition of typically 2% relative to the 1974 data. However, more importantly, the detailed analysis of the experimental response data has significantly improved confidence in the neutron corrections applied to in-core TLD gamma-ray energy deposition measurements. (author)

  13. Validation of response simulation methodology of Albedo dosemeter; Validacao da metodologia de simulacao de resposta de dosimetro de Albedo

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, B.M.; Silva, A.X. da, E-mail: bfreitas@nuclear.ufrj.br [Coordenacao do Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Mauricio, C.L.P. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2016-07-01

    The Instituto de Radioprotecao e Dosimetria developed and runs a neutron TLD albedo individual monitoring service. To optimize the dose calculation algorithm and to infer new calibration factors, the response of this dosemeter was simulated. In order to validate this employed methodology, it was applied in the simulation of the problem of the QUADOS (Quality Assurance of Computational Tools for Dosimetry) intercomparison, aimed to evaluate dosimetric problems, one being to calculate the response of a generic albedo dosemeter. The obtained results were compared with those of other modeling and the reference one, with good agreements. (author)

  14. Dosimetry in nuclear power plants

    International Nuclear Information System (INIS)

    Lastra B, J. A.

    2008-12-01

    To control the occupationally exposed personnel dose working at the Laguna Verde nuclear power plant, two types of dosemeters are used, the thermoluminescent (TLD) which is processed monthly, and the direct reading dosemeter that is electronic and works as daily control of personal dose. In the case of the electronic dosemeters of direct reading conventional, the readings and dose automatic registers and the user identity to which he was assigned to each dosemeter was to carry out the restricted area exit. In activities where the ionizing radiation sources are not fully characterized, it is necessary to relocate the personal dosemeter or assigned auxiliary dosemeters (TLDs and electronics) to determine the dose received by the user to both whole body and in any specific area of it. In jobs more complicated are used a tele dosimetry system where the radiation protection technician can be monitoring the user dose to remote control, the data transmission is by radio. The dosimetry activities are documented in procedures that include dosemeter inventories realization, the equipment and dosemeters calibration, the dosimetry quality control and the discrepancies investigation between the direct reading and TLD systems. TLD dosimetry to have technical expertise in direct and indirect dosimetry and two technicians in TLD dosimetry; electronic dosimetry to have 4 calibration technicians. For the electronic dosemeters are based on a calibrator source of Cesium-137. TLD dosemeters to have an automatic radiator, an automatic reader which can read up to 100 TLD dosemeters per hour and a semiautomatic reader. To keep the equipment under a quality process was development a process of initial entry into service and carried out a periodic verification of the heating cycles. It also has a maintenance contract for the equipment directly with the manufacturer to ensure their proper functioning. The vision in perspective of the dosimetry services of Laguna Verde nuclear power plant

  15. Dose measurements in space by the Hungarian Pille TLD system

    International Nuclear Information System (INIS)

    Apathy, I.; Deme, S.; Feher, I.; Akatov, Y.A.; Reitz, G.; Arkhanguelski, V.V.

    2002-01-01

    Exposure of crew, equipment, and experiments to the ambient space radiation environment in low Earth orbit poses one of the most significant problems to long-term space habitation. Accurate dose measurement has become increasingly important during the assembly (extravehicular activity (EVA)) and operation of space stations such as on Space Station Mir. Passive integrating detector systems such as thermoluminescent dosemeters (TLDs) are commonly used for dosimetry mapping and personal dosimetry on space vehicles. The well-known advantages of passive detector systems are their independence of power supply, small dimensions, high sensitivity, good stability, wide measuring range, resistance to environmental effects, and relatively low cost. Nevertheless, they have the general disadvantage that for evaluation purposes they need a laboratory or large--in mass and power consumption--terrestrial equipment, and consequently they cannot provide time-resolved dose data during long-term space flights. KFKI Atomic Energy Research Institute (KFKI AEKI) has developed and manufactured a series of thermoluminescent dosemeter systems for measuring cosmic radiation doses in the 10 μGy to 10 Gy range, consisting of a set of bulb dosemeters and a compact, self-contained, TLD reader suitable for on-board evaluation of the dosemeters. By means of such a system, highly accurate measurements were carried out on board the Salyut-6, -7 and Mir Space Stations as well as on the Space Shuttle. A detailed description of the system is given and the comprehensive results of these measurements are summarised

  16. Performance and Test Results of Harshaw Pelletised LiF:Mg,Ti TLD Material

    International Nuclear Information System (INIS)

    Velbeck, K.J.; Zhang, L.; Green, R.; Tomlins, P.

    1999-01-01

    BICRON NE has recently introduced a pelletised version of their popular TLD-100, 600 and 700 lithium fluoride based thermoluminescence dosemeters (TLDs). These materials can be used unmounted or in card and ring formats. Applications include whole-body, environmental, medical, and extremity monitoring. The former manufacturing process included purifying, growing doped LiF, grinding, blending, pressing, slicing, and dicing. The new process eliminates the last four steps, replacing them with a pelletising process. This process transforms the material directly from a powder to its final form. This new process provides the benefits of better batch uniformity and excellent dimensional consistency. The testing is described that was performed for the purpose of accepting the pelletised material as a directly interchangeable substitute for the same material produced by the former process. Tests performed include reproducibility, batch homogeneity, linearity, detection threshold, and light sensitivity. (author)

  17. Official dosimetry with individual electronic dosemeters - the concept in Germany

    International Nuclear Information System (INIS)

    Czarwinski, R.; Kaulard, J.; Pfeffer, W.

    2005-01-01

    Full text: Presently, in Germany passive dosemeters (film batches, RPL, TLD) are used for the official individual monitoring of occupational exposed personal. The application of electronic individual dosemeters (EPD) is carried out mainly for the operative radiation protection control particularly in nuclear power engineering companies, big hospitals und research centres. This means in such institutions double monitoring exists - legally and operatively. A crucial advantage of EPD compared to passive dosemeter is the possibility to adapt the monitoring period to the working time in the control area, e.g. a job related monitoring is available. Germany started a project for an optimized implementation of EPD into the official dosimetry. Objective of the project whose results will be described in the paper is the harmonization of radiation protection of companies workers and outside workers concerning the record of individual and job related exposures. The approval of the EPD by the Federal and Laender authorities as an official dosimetric system demands the implementation of special requirements concerning the data acquisition, data transfer and data evaluation. These issues are focuses of the Federal research project, supervised by the Federal Office for Radiation Protection (BfS) and performed by the Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS), Cologne to develop a concept in the first stage. (author)

  18. A TLD-based personal dosemeter system for air crew monitoring

    International Nuclear Information System (INIS)

    Hajek, M.; Berger, T.; Vana, N.

    2003-01-01

    Full text: Due to the complex spectrum of different particles and energies involved, in-flight radiation dosimetry is usually associated with extensive instrumentation. The exposure of air crew personnel to cosmic radiation is paid serious attention, being further enhanced by the release of the European Council Directive 96/29/Euratom which makes the surveillance of crew members an obligatory issue. The high temperature ratio (HTR) method for small and easy-to-handle LiF:Mg,Ti thermoluminescent dosimeters was developed at the Atomic Institute of the Austrian Universities and fulfils these demands by permitting the determination of dose equivalent in radiation fields of unknown composition. The method uses the relative intensity of glow peaks 6 and 7 compared with the dominant peak 5 in the LiF Tl emission as an indication for the average LET and, thus, the mean quality factor of the radiation field. Extensive experiments in various ion beams established a HTR vs. LET calibration curve for the commercially available Tl phosphors TLD-600 and TLD-700. Additionally, the different neutron sensitivity of both types may be exploited for the determination of the dose equivalent delivered from neutrons which dominate at aviation altitudes. However, it is essential that the calibration of the Tl detectors is performed in a neutron environment of similar spectral shape as that encountered in flight. In our case, this constraint was satisfied by the CERN-EU High-Energy Reference Field (CERF). Results of both neutron and total dose equivalent for several different north-bound and trans-equatorial routes are presented, ranging from 2.1 ± 0.1 μSv/h with a 30 % neutron contribution for Vienna-Sydney to 4.9 ± 0.2 μSv/h and a roughly 55 % neutron contribution for Vienna-Tokyo. The measured route doses are compared with CARI-6M calculations. (author)

  19. About the measurements systems with pen and thermoluminescent dosemeters; Sobre los sistemas de medicion con dosimetros de pluma y los termoluminiscentes

    Energy Technology Data Exchange (ETDEWEB)

    Cortes I, M.E.; Ramirez G, F.P. [Instituto Mexicano del Petroleo, Eje Central Lazaro Cardenas 152. 07730 Mexico D.F. (Mexico)

    1998-12-31

    In this work it is presented dosimetric data obtained with pen and thermoluminescent dosemeters, which are used by the Occupational Exposure Personnel (OEP) of the Mexican Petroleum Institute (IMP)(1). It was marked several great characteristics as for example, the differences among units which use one and another dosemeter type. Likewise, it is given to know diverse problems that were had in the IMP at relating the data obtained with these dosemeters (which utilizes OEP) and the ICRP 60 recommendations 1990. One of the most important difficulties is to satisfy the recommended limits by ICRP, particularly those that are referring to the units and their complex calculations. With respect to the unities, the ICRP makes reference at the concepts `dose equivalent` and `effective dose` with the sievert unit, that the General Regulations for Radiological Safety associates with `dose equivalent` and `effective dose equivalent`. It was illustrated the type of dosimetric statistics which are obtained with the TLD lectures and a OEP pen dosemeter during 1997. (Author)

  20. Analysis of read-out heating rate effects on the glow peaks of TLD-100 using WinGCF software

    Energy Technology Data Exchange (ETDEWEB)

    Bauk, Sabar, E-mail: sabar@usm.my [Physics Section, School of Distance Education, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Hussin, Siti Fatimah [School of Physics, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Alam, Md. Shah [Physics Section, School of Distance Education, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Physics Department, Shahjalal University of Science and Technology, Sylhet (Bangladesh)

    2016-01-22

    This study was done to analyze the effects of the read-out heating rate on the LiF:Mg,Ti (TLD-100) thermoluminescent dosimeters (TLD) glow peaks using WinGCF computer software. The TLDs were exposed to X-ray photons with a potential difference of 72 kVp and 200 mAs in air and were read-out using a Harshaw 3500 TLD reader. The TLDs were read-out using four read-out heating rates at 10, 7, 4 and 1 °C s{sup −1}. It was observed that lowering the heating rate could separate more glow peaks. The activation energy for peak 5 was found to be lower than that for peak 4. The peak maximum temperature and the integral value of the main peak decreased as the heating rate decreases.

  1. Tl response of LiF:Mg, Cu, P + PTFE to Am-Be neutrons

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    2000-01-01

    In different laboratories of the world it is followed the research about development of new Tl materials, whose main characteristics should be their equivalence with the tissue and their high sensibility to any type of radiation. The study consists in to measure the Tl peak intensity which TLD-100 presents at being irradiated with neutrons and that appears over 250 Centigrade, for compare it with the Tl intensity of the LiF: Mg, Cu, P + PTFE dosemeters. However, not all dosemeters of the same group show the interesting peak, by this only can be the total Tl intensity of dosemeters studied. In the ININ dosemeters development laboratory, we have developed a Tl material of lithium fluoride activated with magnesium, copper and phosphorus (LiF: Mg, Cu, P) that in polycrystalline powder form is almost 35 times more sensitive than the TLD-100 commercial dosemeter of Harshaw/Filtrol, USA. With the use of polytetrafluorethylene (PTFE) and with the above described Tl material, it has been possible to obtain dosemeters in pellet form of LiF: Mg, Cu, P + PTFE. (Author)

  2. TLD Intercomparison in accelerators for radiotherapy in three Latin american countries; Intercomparacion TLD en aceleradores para radioterapia en tres paises latinoamericanos

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E.; Azorin N, J.; Perez, M.A.; Picon, C.; Castellanos, E.; Plazas, M.C.; Murcia, G.; Archundia, L. [Depto. El Hombre y su Ambiente. Universidad Autonoma Metropolitana, Calz. Del Hueso 1100, 04960 Mexico D.F. (Mexico)

    1998-12-31

    In Radiotherapy one of the objectives is to establish and to give follow up to quality assurance programs which make sure that the doses administered to the patients with cancer are a high probability of a success in external radiation. Likewise, one of the present preoccupations of the United Nations Agencies as well as the International Atomic Energy Agency and the Pan-American Health Organization is the optimal employment of the radiations in the treatment of cancer patients since the administered dose in Radiotherapy suffers considerable variations by the lack of quality assurance programs. The use of Electron linear accelerators requires a program of quality assurance that includes expert personnel, equipment and adequate facilities. The more used methodology for the dosimetry calibration and characterization of X-ray beams and high energy electrons for radiotherapy use is using a ionization chamber dosemeter calibrated in a regional secondary standardization laboratory. However, to establish and give follow up to the quality assurance programs it is necessary the dosimetric intercomparison through TLD. In this study it was designed plastic phantoms with TLD crystals and it was made its characterization to realize an absorbed dose analysis in the crystals exposed at X-ray beams 6 MV and high energy electrons 10 and 12 MeV to standardize the dosimetric procedures and proceeding to realize an International Pilot intercomparison of absorbed doses in TLD crystals in three Latin American countries: Mexico, Peru and Colombia with the participation of accelerators of five different institutions. The found results show that the majority of the measured doses with TLD in the different accelerators were in the 0.95-1.05 range though it had two cases outside of this range. The use of the phantoms with TLD crystals shows that they are of excellent aid to make analysis of the doses administered to the patients and an intercomparison of results to standardize procedures at

  3. Obtention of a thermoluminescent material for dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    1990-01-01

    The thermoluminescent dosemeters are small crystals which suffer changes in their structure by the radiation effect, being displaced the electrons toward higher energy levels. On heating the previously irradiated crystals, the electrons come back to their base state emitting light photons. The light quantity emitted is proportional to the received radiation dose. The light quantity emitted is proportional to the received radiation dose. The lithium fluoride is one of the thermoluminescent materials considered as tissue equivalents by having a low effective atomic number (Z ef ). At present, the more used commercial product used of this type is the TLD-100*. In this work the obtained results in the preparation of the lithium fluoride thermoluminescent material are presented. This is activated with magnesium (Mg) and titanium (Ti), which we have labelled as: LiF: Mg, Ti. The results from the tests performed for verifying his thermoluminescent properties are presented too, as powder form as in pellets form. These tests were performed in simultaneous form with TLD-100 samples, which is considered as reference. The LiF: Mg, Ti thermoluminescent material manufactured in the ININ presents similar dosimetric characteristics to those ones of the TLD-100. Therefore being able to replace the imported dosemeters. * (TLD-100 is a commercial trademark registered by Harshaw/Filtrol (US) for LiF: Mg, Ti Tl dosemeters) (Author)

  4. Obtention of a thermoluminescent material for dosimetry of ionizing radiation; Obtencion de un material termoluminiscente para dosimetria de la radiacion ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, P R

    1990-07-01

    The thermoluminescent dosemeters are small crystals which suffer changes in their structure by the radiation effect, being displaced the electrons toward higher energy levels. On heating the previously irradiated crystals, the electrons come back to their base state emitting light photons. The light quantity emitted is proportional to the received radiation dose. The light quantity emitted is proportional to the received radiation dose. The lithium fluoride is one of the thermoluminescent materials considered as tissue equivalents by having a low effective atomic number (Z{sub ef}). At present, the more used commercial product used of this type is the TLD-100*. In this work the obtained results in the preparation of the lithium fluoride thermoluminescent material are presented. This is activated with magnesium (Mg) and titanium (Ti), which we have labelled as: LiF: Mg, Ti. The results from the tests performed for verifying his thermoluminescent properties are presented too, as powder form as in pellets form. These tests were performed in simultaneous form with TLD-100 samples, which is considered as reference. The LiF: Mg, Ti thermoluminescent material manufactured in the ININ presents similar dosimetric characteristics to those ones of the TLD-100. Therefore being able to replace the imported dosemeters. * (TLD-100 is a commercial trademark registered by Harshaw/Filtrol (US) for LiF: Mg, Ti Tl dosemeters) (Author)

  5. The Dependence of the Dose Response Supralinearity of Peak 5 in TLD-100 on Recombination Temperature

    International Nuclear Information System (INIS)

    Horowitz, Y.S.; Satinger, D.; Oster, L.

    1999-01-01

    Isothermal readout of LiF:Mg,Ti (TLD-700) has recently been used to study the dependence of the supralinearity of peak 5 on recombination temperature. The results were interpreted to be in conflict with earlier results which investigated the effect of readout heating rate on the supralinearity of peak 5 in TLD-100. In this work the two experiments are inspected in greater detail. It is illustrated that the isothermal decay data is not in conflict with the heating rate data. However, the heating rate results do apparently indicate a strong transition in the temperature dependence of the relative strengths of the recombination and competitive cross sections at approximately 235 deg. C, which requires further study and analysis. (author)

  6. On the calibration of radiotherapy dosemeters in Australia

    International Nuclear Information System (INIS)

    Huntley, R.; Kotler, L.; Webb, D.

    2000-01-01

    Full text: Dosemeters for external beam radiotherapy are calibrated in Australia by ARPANSA, against the national primary standards of exposure and absorbed dose. The primary standards are free air chambers for exposure at low and medium energy X-rays, a graphite cavity chamber for exposure at 60 Co, and a graphite calorimeter for absorbed dose at 60 Co and high energy (MV) X -rays. Radiotherapy dosemeters are calibrated against these standards using a well documented formalism to provide calibration factors suitable for use with dosimetry protocols. A dosemeter usually comprises an ionization chamber connected to an independent electrometer. These are calibrated separately if possible. A combined calibration factor is reported together with the electrometer calibration factor (sensitivity). The dosimetry protocol used in radiotherapy centres in Australia and New Zealand is currently the simplified version of the IAEA TRS277 protocol, published by the New Zealand NRL and recommended by the ACPSEM. This protocol requires the use of an exposure or air kerma calibration factor at 60 Co (Nx or Nk) to evaluate the absorbed dose to air calibration factor N D . The chamber is then placed in a water phantom with its centre displaced from the reference point by p eff . ARPANSA can also supply calibration factors in absorbed dose to water (N D,w ), as required as input to the new IAEA CoP. If an absorbed dose to water calibration factor is used by the radiotherapy centre, the chamber should be placed with its centre at the reference point in the water phantom. ARPANSA has for some years coordinated the participation of Australian radiotherapy centres in the IAEA TLD Quality Audit service. Note that this service does not represent a calibration and should not be referred to as such. The only calibration is that provided by ARPANSA for a reference dosemeter at each radiotherapy centre. As soon as the ANSTO SSDL is operational, calibrations of reference dosemeters will also be

  7. A quality control program for the thermoluminescence dosimeter (TLD) in personnel radiation monitoring

    International Nuclear Information System (INIS)

    Seo, Kyung Won; Kim, Jang Lyul; Lee, Sang Yoon; Lee, Hyung Sub

    1994-01-01

    High quality radiation dosimetry is essential for workers who rely upon personal dosemeters to record the amount of radiation to which they are exposed. The ministry of science and technology (MOST) issued a ministerial ordinance (No 199-15) about the technical criteria on personnel dosimeter processors on 1992. The purpose of this quality control program is to prescribe the procedures approved by the management of KAERI for implementing a quality badge service by means of TLD for personnel working in an area where they may be exposed to ionization radiation. (Author) 10 refs

  8. Al{sub 2} O{sub 3}:Cr,Ni: a possible thermoluminescent dosemeter; Al{sub 2} O{sub 3}: Cr, Ni un posible dosimetro termoluminiscente

    Energy Technology Data Exchange (ETDEWEB)

    Mariani R, Francisco; Roman B, Alvaro; Saavedra S, Renato [Pontificia Univ. Catolica de Chile, Santiago (Chile). Facultad de Fisica; Ibarra S, Angel [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain). Seccion Materiales para Fusion

    1997-12-31

    Results from a study on the thermoluminescent (Tl) emission from Al{sub 2} O{sub 3}:Cr,Ni are presented. The measurements were obtained for evaluation of the Al{sub 2} O{sub 3}:Cr,Ni dosimetric properties. Different crystal batches were exposed to two kind of ionizing radiation (X-ray and {beta}{sup -}). The Tl spectrum has a main peak with high thermal and optical stability, deviating from linearity for doses lower than 3.6 Gy. Furthermore, this material shows advantages (thermal resistance, reusability, multiple heating cycles) compared to TLD-100. Measured Al{sub 2} O{sub 3}:Cr,Ni properties indicate that it could be used as a dosemeter. (author). 5 refs., 4 figs.

  9. TLD system for the monitoring of the environmental radioactivity

    International Nuclear Information System (INIS)

    Stochioiu, Ana; Sahagia, Maria; Tudor, Ion

    2008-01-01

    The paper presents a high sensitivity TLD system, designed for the survey of the environmental radioactivity. It is based on the use of TL detectors type LiF:Mg, Cu, P, commercially known as GR-200A. The dosimeter designed in our Institute, contains 3 detectors, and the measurement value is calculated as the arithmetic mean. A very sensitive, TL Reader, READER ANALYSER RA'94 was chosen and an optimal thermal cycle was designed, such as to enhance the measurement performances. For each placement, a set of 3 dosemeters is used, and survey intervals from 1 to 100 days, depending on the radioactivity level and reporting requirements, are selected. The technical characteristics of the system were determined by exposing the dosimeters in reference X and gamma radiation fields, such as required by the IEC standard 61066:iun.2006 'Thermoluminescence dosimetry systems for personal and environmental monitoring'. The main technical parameters are of highest quality and recommend it for use in the survey of the environmental radioactivity, at the level of ambient dose equivalent rate, due to normal natural radioactivity, in open areas. The paper describes the method of characterisation and measurement results, as well as their relevance. (author)

  10. Reproducibility study of TLD-100 micro-cubes at radiotherapy dose level

    International Nuclear Information System (INIS)

    Rosa, Luiz Antonio R. da; Regulla, Dieter F.; Fill, Ute A.

    1999-01-01

    The precision of the thermoluminescent response of Harshaw micro-cube dosimeters (TLD-100), evaluated in both Harshaw thermoluminescent readers 5500 and 3500, for 1 Gy dose value, was investigated. The mean reproducibility for micro-cubes, pre-readout annealed at 100 deg. C for 15 min, evaluated with the manual planchet reader 3500, is 0.61% (1 standard deviation). When micro-cubes are evaluated with the automated hot-gas reader 5500, reproducibility values are undoubtedly worse, mean reproducibility for numerically stabilised dosimeters being equal to 3.27% (1 standard deviation). These results indicate that the reader model 5500, or, at least, the instrument used for the present measurements, is not adequate for micro-cube evaluation, if precise and accurate dosimetry is required. The difference in precision is apparently due to geometry inconsistencies in the orientation of the imperfect micro-cube faces during readout, requiring careful and manual reproducible arrangement of the selected micro-cube faces in contact with the manual reader planchet

  11. Extra Dose Due to Extravehicular Activity During the NASA4 Mission, Measured by an On-Board TLD System

    Energy Technology Data Exchange (ETDEWEB)

    Deme, S.; Apathy, I.; Hejja, I.; Lang, E.; Feher, I. [Budapest (Hungary)

    1999-07-01

    A microprocessor-controlled on-board TLD system, 'Pille'96', was used during the NASA4 (1997) mission to monitor the cosmic radiation dose inside the Mir Space Station and to measure the extra dose to two astronauts in the course of their extravehicular activity (EVA). For the EVA dose measurements, CaSO{sub 4}:Dy bulb dosemeters were located in specially designed pockets of the ORLAN spacesuits. During an EVA lasting 6 h, the dose ratio inside and outside Mir was measured. During the EVA, Mir crossed the South Atlantic Anomaly three times. Taking into account the influence of these three crossings the mean EVA/internal dose rate ratio was 3.2. Internal dose mapping using CaSO{sub 4}:Dy dosemeters gave mean dose rates ranging from 9.3 to 18.3 {mu}Gy.h{sup -1} at locations where the shielding effect was not the same. Evaluation results of the high temperature region of LiF dosemeters are given to estimate the mean LET. (author)

  12. The MCNP-4C2 design of a two element photon/electron dosemeter that uses magnesium/copper/phosphorus doped lithium fluoride.

    Science.gov (United States)

    Eakins, J S; Bartlett, D T; Hager, L G; Molinos-Solsona, C; Tanner, R J

    2008-01-01

    The Health Protection Agency is changing from using detectors made from 7LiF:Mg,Ti in its photon/electron personal dosemeters, to 7LiF:Mg,Cu,P. Specifically, the Harshaw TLD-700H card is to be adopted. As a consequence of this change, the dosemeter holder is also being modified not only to accommodate the shape of the new card, but also to optimize the photon and electron response characteristics of the device. This redesign process was achieved using MCNP-4C2 and the kerma approximation, electron range/energy tables with additional electron transport calculations, and experimental validation, with different potential filters compared; the optimum filter studied was a polytetrafluoroethylene disc of diameter 18 mm and thickness 4.3 mm. Calculated relative response characteristics at different angles of incidence and energies between 16 and 6174 keV are presented for this new dosemeter configuration and compared with measured type-test results. A new estimate for the energy-dependent relative light conversion efficiency appropriate to the 7LiF:Mg,Cu,P was also derived for determining the correct dosemeter response.

  13. Fast neutron responses of CaF2:Tm Teflon TLD discs of different thicknesses

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Hoffmann, W.

    1986-01-01

    The fact that in CaF 2 :Tm (TLD-300) the ratio of the heights of thermoluminescence (TL) glow peaks at 240 0 C and 150 0 C is greater for irradiations by high LET radiations than by gamma rays has been found useful for the simultaneous and separate measurement of fast neutron and gamma ray absorbed doses. A recent study has indicated that the mixed field dosimetric characteristics of CaF 2 :Tm could be significantly improved by using thin TLDs. In the present study, CaF 2 :Tm Teflon TLD discs of thickness as low as 0.05 mm were evaluated. The thin discs could be read out by using normal planchette heating if a 400 0 C heat treatment is given to the discs prior to irradiation and TL readout. Influence of encapsulation of thin dosemeters was studied and their utility in situations such as interface dosimetry is discussed. (author)

  14. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P thermoluminescent dosemeter and its applications in diagnostic radiology

    International Nuclear Information System (INIS)

    Fung, K.K.L.

    2000-12-01

    The recent introduction and development of the thermoluminescent (T.L.) phosphor material LiF:Mg,Cu,P (usually named TLD100H or GR200A) has aroused intense interest of scientists in the field of radiation dosimetry due to its very favourable dosimetric characteristics. Both conventional LiF:Mg,Ti (TLD100) and LiF:Mg,Cu,P T.L. phosphors are tissue-equivalent but GR200A outperforms in respect of its very much higher sensitivity, by a factor of greater than 25, and a dose detection threshold of less than 1 μGy. A reproducible readout and annealing regime was developed in the initial part of this study with the newly installed automatic TLD (Thermoluminescence Dosimetry) apparatus in the X-ray and Radiation Physics Laboratories of the Hong Kong Polytechnic University. Basic dosimetric characteristics of this T.L. dosemeter (supplied by Harshaw-Bicron Co.) were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. Dosimetric characteristics which included linearity, reproducibility, batch uniformity, energy response, and minimum detectable dose were studied using X-rays in the commonly used diagnostic radiology energy range. Favourable dosimetric characteristics were observed from this T.L. phosphor, which agrees well with published studies. The effect of the number of thermal treatment cycles in the initialisation process on dosimetric properties of this T.L. phosphor was also investigated. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom using facilities both in these laboratories and also in radiology departments of various district hospitals in Hong Kong. Radiation absorbed dose from the direct or scattered beam, at critical sites inside and on the surface of the phantom, were measured in these radiological studies. The special focus in some of these studies was to

  15. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P thermoluminescent dosemeter and its applications in diagnostic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Fung, K.K.L

    2000-12-01

    The recent introduction and development of the thermoluminescent (T.L.) phosphor material LiF:Mg,Cu,P (usually named TLD100H or GR200A) has aroused intense interest of scientists in the field of radiation dosimetry due to its very favourable dosimetric characteristics. Both conventional LiF:Mg,Ti (TLD100) and LiF:Mg,Cu,P T.L. phosphors are tissue-equivalent but GR200A outperforms in respect of its very much higher sensitivity, by a factor of greater than 25, and a dose detection threshold of less than 1 {mu}Gy. A reproducible readout and annealing regime was developed in the initial part of this study with the newly installed automatic TLD (Thermoluminescence Dosimetry) apparatus in the X-ray and Radiation Physics Laboratories of the Hong Kong Polytechnic University. Basic dosimetric characteristics of this T.L. dosemeter (supplied by Harshaw-Bicron Co.) were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. Dosimetric characteristics which included linearity, reproducibility, batch uniformity, energy response, and minimum detectable dose were studied using X-rays in the commonly used diagnostic radiology energy range. Favourable dosimetric characteristics were observed from this T.L. phosphor, which agrees well with published studies. The effect of the number of thermal treatment cycles in the initialisation process on dosimetric properties of this T.L. phosphor was also investigated. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom using facilities both in these laboratories and also in radiology departments of various district hospitals in Hong Kong. Radiation absorbed dose from the direct or scattered beam, at critical sites inside and on the surface of the phantom, were measured in these radiological studies. The special focus in some of these studies was to

  16. Thermoluminescence of pure LiF and Lif (TLD-100) irradiated at room temperature; Termoluminiscencia en LiF puro y LiF dosimetrico (TLD-100), irradiados a temperatura ambiente

    Energy Technology Data Exchange (ETDEWEB)

    Sagastibelza Chivite, F

    1980-07-01

    The thermoluminescence of pure LiF and LiF (TLD-100) crystals irradiated at room temperature with x - or gamma-rays has been studied up to 460 degree centigree. For most of the glow peaks found the kinetics, preexponential factors and activation energies have been determined. These parameters have been obtained by means of the isothermal method. The study of the thermal annealing of the radiation induced F and Z centres has allow to show that there is a correlation among the glow peaks and the annealing stages of these centres. It is concluded that the F and Z - centres play the role of recombination centres for halogen interstitial atom thermally released from traps. Light emission occurs in this recombination. (Author) 120 refs.

  17. Electronic personal dosemeters

    International Nuclear Information System (INIS)

    Marshall, T.O.; Bartlett, D.T.; Burgess, P.H.; Cranston, C.S.; Higginbottom, D.J.; Sutton, K.W.

    1990-01-01

    Personal dosimetry services approved by their national authorities for category A workers, invariably use passive dosemeters incorporating photographic film or thermoluminescent detectors. However, the performance characteristics of electronic dosemeters has improved substantially over the past decade to such an extent that in the opening lecture of the Solid State Dosimetry Conference at Oxford in 1986 the development of an electronic 'smart card' based on a silicon detector was briefly discussed. This idea has been taken up and at least one development programme is in progress aimed at the production of an electronic dosemeter suitable for use as a legal device. The more important performance requirements of personal dosemeters for this purpose are discussed and the earlier electronic dosemeter designs and the latest devices under development to meet this specification are compared. (author)

  18. On the determination of the post-irradiation time from the glow curve of TLD-100

    International Nuclear Information System (INIS)

    Weinstein, M.; German, U.; Dubinsky, S.; Alfassi, Z.B.

    2003-01-01

    The ratio of peak 3 to the sum of peaks 4 + 5 in TLD-100 was measured for various pre-irradiation and post-irradiation time periods, under conditions characteristic of routine personal dosimetry. It was confirmed that the value of this ratio depends only on the elapsed time between the prior readout and the present one, independent of the moment when the irradiation took place during the total time interval (storage time). This effect indicates that fading of peak 3 seems to be due mainly to changes in the unoccupied traps, and not to decay of trapped charges, being almost independent of the presence of electrons or holes in the traps. This observation leads to the conclusion that the suggestions in the past to use the decay of peak 3 in TLD-100 for the measurement of the elapsed time between irradiation and readout may have been wrong. On the other hand, the decay of peak 2 can be used to measure the elapsed time from irradiation, since the rate of decay is different when related to pre-irradiation and post-irradiation times, indicating a much higher decay rate of the trapped charges (Randall-Wilkins decay). However, because of the fast decay rate of peak 2, its use for determination of the elapsed time since irradiation is of little practical significance. (author)

  19. Comparison test of electronic dosemeters

    International Nuclear Information System (INIS)

    Butterweck, G.; Zimmerli, H.P.; Wernli, C.

    2001-01-01

    To assist with a planned purchase of electronic dosemeters by the Swiss Federal Office for Civil Protection, the calibration laboratory of the Paul Scherrer Institute performed tests on 11 types of electronic dosemeters manufactured by 10 European and American companies. The technical specifications for the World Trade Organisation (WTO) tendering procedure were largely in accord with the specifications of the international standard IEC 61526. First tests were performed with samples from each type of dosemeter. The reproducibility of a dose of 0.1 mSv generated with 137 Cs radiation at a dose rate of 2.1 mSv.h -1 was found adequate for all tested dosemeter types. The response for environmental levels of radiation showed a large variation, indicating insufficient background correction of some dosemeters. A very high dose rate of 10 Sv.h -1 provoked faulty dose readings for more than half of the tested dosemeters. Dosemeter response for low-energy photon radiation was satisfactory for two of the tested dosemeter types. Four dosemeter types were selected for extended technical tests. Three samples of each of these dosemeter types were purchased. For drop and temperature tests the specifications of the WTO tendering procedure outranged the specification of the IEC standard. Whereas even at a temperature of -25 deg. C the tested dosemeters functioned normally, drops from a height of 2 m onto a wooden surface rendered the samples of two dosemeter types inoperative. (author)

  20. TLD Intercomparison in accelerators for radiotherapy in three Latin american countries

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin N, J.; Perez, M.A.; Picon, C.; Castellanos, E.; Plazas, M.C.; Murcia, G.; Archundia, L.

    1998-01-01

    In Radiotherapy one of the objectives is to establish and to give follow up to quality assurance programs which make sure that the doses administered to the patients with cancer are a high probability of a success in external radiation. Likewise, one of the present preoccupations of the United Nations Agencies as well as the International Atomic Energy Agency and the Pan-American Health Organization is the optimal employment of the radiations in the treatment of cancer patients since the administered dose in Radiotherapy suffers considerable variations by the lack of quality assurance programs. The use of Electron linear accelerators requires a program of quality assurance that includes expert personnel, equipment and adequate facilities. The more used methodology for the dosimetry calibration and characterization of X-ray beams and high energy electrons for radiotherapy use is using a ionization chamber dosemeter calibrated in a regional secondary standardization laboratory. However, to establish and give follow up to the quality assurance programs it is necessary the dosimetric intercomparison through TLD. In this study it was designed plastic phantoms with TLD crystals and it was made its characterization to realize an absorbed dose analysis in the crystals exposed at X-ray beams 6 MV and high energy electrons 10 and 12 MeV to standardize the dosimetric procedures and proceeding to realize an International Pilot intercomparison of absorbed doses in TLD crystals in three Latin American countries: Mexico, Peru and Colombia with the participation of accelerators of five different institutions. The found results show that the majority of the measured doses with TLD in the different accelerators were in the 0.95-1.05 range though it had two cases outside of this range. The use of the phantoms with TLD crystals shows that they are of excellent aid to make analysis of the doses administered to the patients and an intercomparison of results to standardize procedures at

  1. Acid dip for dosemeter

    International Nuclear Information System (INIS)

    Stewart, J.C.; McWhan, A.F.

    1982-01-01

    Background signal in a PTFE based dosemeter caused by impurities in the PTFE and in the active component such as lithium fluoride is substantially reduced by treating the dosemeter with acid. The optimum treatment involves use of hydrofluoric acid at room temperature for approximately one minute, followed by thorough washing with methanol, and finally drying. This treatment is best applied after the original manufacture of the dosemeters. It may also be applied to existing dosemeters after they have been in use for some time. The treatment produces a permanent effect in reducing both the light induced signal and the non-light induced signal. The process may be applied to all types of dosemeter manufactured from PTFE or other plastics or resins which are able to resist brief exposure to acid. The treatment works particularly well with dosemeters based on PTFE and lithium fluoride. It is also applicable to dosemeters based on calcium sulphate, lithium borate and magnesium borate. Acids which may be used include hydrofluoric, hydrochloric, nitric, phosphoric and sulphuric. (author)

  2. Determination of isodose curves in Radiotherapy using an Alanine/ESR dosemeter

    International Nuclear Information System (INIS)

    Chen, F.; Baffa, O.; Graeff, C.F.O.

    1998-01-01

    It was studied the possible use of an Alanine/ESR dosemeter in the isodose curves mapping in normal treatments of Radiotherapy. It was manufactured a lot of 150 dosemeters with base in a mixture of D-L Alanine dust (80 %) and paraffin (20 %). Each dosemeter has 4.7 mm diameter and 12 mm length. A group of 100 dosemeters of the lot were arranged inside 50 holes of the slice 25 of the phantom Rando Man. The phantom irradiation was realized in two opposed projections (AP and PA) in Co-60 equipment. A group of 15 dosemeters was take of the same lot for obtaining the calibration curve in a 1-20 Gy range. After irradiation the signal of each dosemeter was measured in an ESR spectrometer operating in the X-band (∼ 9.5 GHz) and the wideness of Alanine ESR spectra central line was correlated with the radiation dose. The wideness dose calibration curve resulted linear with a correlation coefficient 0.9996. The isodose curves obtained show a profile enough similar at comparing with the theoretical curves. (Author)

  3. Neutron dosimetry inside the containment building of Spanish nuclear power plants with PADC based dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Fuste, M.J. [Grup de Fisica de les Radiacions. Departament de Fisica. Edifici C. Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain); Domingo, C., E-mail: carles.domingo@uab.ca [Grup de Fisica de les Radiacions. Departament de Fisica. Edifici C. Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain); Amgarou, K.; Bouassoule, T.; Castelo, J. [Grup de Fisica de les Radiacions. Departament de Fisica. Edifici C. Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain)

    2009-10-15

    The Spanish Nuclear Safety Council (Consejo de Seguridad Nuclear, CSN) recommends performing neutron individual dose assignments at workplaces based on ambient dose equivalent measurements using area monitors and by estimating the amount of time that workers spend in the different monitored environments. In addition, some Spanish nuclear power plants estimate the neutron dose equivalent using albedo thermoluminescence dosemeters (TLD). In the period 2004-2006, our group, together with other research centers, participated in a project, funded by the CSN, with the support of the Spanish Nuclear Power Plants Association (UNESA), to investigate in situ which could be the best practical procedure for individual neutron dose monitoring in nuclear power plants. As part of this survey, several units of the UAB PADC based neutron dosemeter were exposed, on a methacrylate phantom simulating a human body, at four different places inside the containment building of the Asco I nuclear power plant. The influence of different types of calibration neutron fields is analysed and the dose equivalent for each point is estimated.

  4. Study about the feasibility of using an electret dosemeter as a personal dosemeter

    International Nuclear Information System (INIS)

    Leitao, I.P.

    1983-01-01

    A feasibility study of the electret dosemeters as a personnel dosemeter was carried out. Preliminary tests were applied, in order to assess the dosemeter response to radiation, linearity, stability, reproductibility, direcional dependence and energy dependence in energy range from 33 to 1250 KeV. In general the results are in agreement with the recommendations of the Commision of the European Communities (CEC) for the use of this device as a personnel dosemeter with the exception of the energy dependence and the stability at medium term. (Author) [pt

  5. A new electret dosemeter for radiotherapy

    International Nuclear Information System (INIS)

    Rodrigues, L.N.

    1985-01-01

    The results obtained with a new plane electret dosemeter for use in Radiotherapy are presented. The working principle of the electret dosemeter in based on the use of the electret field the ion collecting field, similarly to an ionization chamber, and as charge integrator detector. The dosemeter had, initialy, a cylindrical geometry. The results attained with it's calibration curve concerning the sensitivity, the stability and the reproducibility lead to changes in the dosemeter geometry. A plane geometry dosemeter was built in order to increase the useful exposure range. The plane dosemeter sensitivity dependence was measured versus the electret charging conditions, the chamber volume and wall material (aluminium, brass and stainless steel). The stainless steel dosemeter showed the best results. This dosemeter has the following characteristics: sensitivity 10 -13 C/R, volume 0.20 cm 3 . Compared to the Baldwin-Farmer dosemeter, this results are fairly good. A multiple electret dosemeter was developed to monitor the uniformity of the radiation beam for a Cobalt Teletherapy unit. The intercomparasion with the Baldwin-Farmer unit presented a maximum variation of 3%. (author) [pt

  6. A gamma/neutron-discriminating, Cooled, Optically Stimulated Luminescence (COSL) dosemeter

    International Nuclear Information System (INIS)

    Eschbach, P.A.; Miller, S.D.

    1992-07-01

    The Cooled Optically Stimulated Luminescence (COSL) of CaF 2 :Mn (grain sizes from 0.1 to 100 microns) powder embedded in a hydrogenous matrix is reported as a function of fast-neutron dose. When all the CaF 2 :Mn grains are interrogated at once, the COSL plastic dosemeters have a minimum detectable limit of 1 cSv fast neutrons; the gamma component from the bare 252 cf exposure was determined with a separate dosemeter. We report here on a proton-recoil-based dosemeter that generates pulse height spectra, much like the scintillator of Hornyak, (2) to provide information on both the neutron and gamma dose

  7. Thermoluminescence of pure LiF and Lif (TLD-100) irradiated at room temperature

    International Nuclear Information System (INIS)

    Sagastibelza Chivite, F.

    1980-01-01

    The thermoluminescence of pure LiF and LiF (TLD-100) crystals irradiated at room temperature with x - or gamma-rays has been studied up to 460 degree centigree. For most of the glow peaks found the kinetics, preexponential factors and activation energies have been determined. These parameters have been obtained by means of the isothermal method. The study of the thermal annealing of the radiation induced F and Z centres has allow to show that there is a correlation among the glow peaks and the annealing stages of these centres. It is concluded that the F and Z - centres play the role of recombination centres for halogen interstitial atom thermally released from traps. Light emission occurs in this recombination. (Author) 120 refs

  8. Measure of the attenuation curve of a beam of X-rays with TLD-100 dosimeters of LiF; Medicion de la curva de atenuacion de un haz de rayos X con dosimetros TLD-100 de LiF

    Energy Technology Data Exchange (ETDEWEB)

    Bonzi, E. V.; Mainardi, R. T. [Universidad Nacional de Cordoba, Facultad de Matematica, Astronomia y Fisica, Av. Haya de la Torre y Av. Medina Allende s/n, Ciudad Universitaria, Cordoba (Argentina); Germanier, A. [Ministerio de Ciencia y Tecnologia, Ceprocor, Unidad de Estudios Fisicos, Alvarez de Arenas 230, X5004AAP Barrio Juniors, Cordoba (Argentina); Delgado, V. [Universidad Complutense de Madrid, Departamento de Fisica Medica, Ciudad Universitaria, 28040 Madrid (Spain)

    2011-10-15

    The attenuation curve of a beam of X-rays represents the beam intensity in function of the attenuator thickness interposed between the source and the detector. To know with the major possible precision the attenuation curve is indispensable in procedures of spectral reconstruction. Their periodic measuring also offers valuable information on the correct operation of a tube of X-rays, diagnostic or therapy, when not have a specific detector for that activity. In this work was measured the attenuation curve of a tube of X-rays operated to 50 kV and 0.5 ma, using existent elements in any diagnostic or therapy laboratory with radiations. In the measures commercial aluminum foil was used, bent until 24 times and thermoluminescent dosimeters TLD 100 - LiF. Also, for comparison, was measured this attenuation curve with an ionization chamber brand Capintec model 192. Was determined by X-rays fluorescence the composition of the aluminium foil, since the present elements in the alloy can to affect the form of the attenuation curve. It is interesting to observe that these elements are in very low proportion (ppm) that they do not alter the attenuation capacity of the pure aluminium. Finally in a precision balance we weigh a big piece (30 cm x 100 cm) of aluminium foil and we obtained the thickness in g/c m2. It is possible to obtain attenuation curves of a beam of X-rays, with a high precision procedure and reproducibility. The use of TLD-100 dosimeters of LiF or similar makes that this activity was also quick and simple. (Author)

  9. Alarm personal dosemeter

    International Nuclear Information System (INIS)

    Nunomiya, Tomoya; Yamauchi, Hideshi; Shibata, Tetsuo

    2007-01-01

    Fuji Electric advanced the development of the conventional alarm personal dosemeter (APD) by adopting JIS Z 4312 (2002), which reflects IEC61526 (1998), and by improving the radiation performance characteristics, electromagnetic performance characteristics and mechanical performance characteristics of the APD (acquiring a CE marking). This new dosemeter will target overseas market in the future. The APD is a suitable dosemeter for detecting and monitoring radiation exposure to personnel working in the controlled areas of nuclear facilities, such as nuclear power stations. The APD product line includes 'gamma ray', 'gamma ray + beta ray' and 'gamma ray + neutron' models. (author)

  10. X-rays individual dose assessment using TLD dosimeters

    International Nuclear Information System (INIS)

    Salas, Carlos

    2008-01-01

    This paper describes the methodology used in Embalse NPP for measuring individual X-ray dose in dentists and radiologists, who work in areas near the plant. Personnel is provided with TLD personal dosimeters for thoracic use, as well as TLD ring dosimeters. This individual X-ray dosimetry is fundamental in order to know the effective energy coming from the radiation field, since the dosimetry factors depend on it. On the other hand, the response of the TLD crystals also depends of the effective energy; this accentuates the problem when assessing the individual dose. The X-ray dosimeter must simultaneously determine the value of the effective energy and the corresponding dose value. The basic principle for determining effective energy is by using at least two different TLD materials covered by filters of different thickness. The TLD materials used have totally energy responses. Therefore, different readouts from each of the crystals are obtained. The ratio between both readouts provides a factor that depends of the effective energy but that is 'independent' from the exposure values irradiated to the dosimeter. The Personal TLD dosimeter currently in use is Bicron-Harshaw. It comprises a carrier model 8807. This carrier contains a card model 2211 which groups two TLD 200 crystals and two TLD 100 crystals. It has internal filters at each side of the TLD 200 crystals. The periodical calibration of these dosimeters consists in the irradiation of some dosimeters with different X-ray energy beams in the National Atomic Energy Commission (CNEA). This dosimeter was used, by the National Regulatory Authority (ARN) in several comparisons, always getting satisfactory results. (author)

  11. Measurement of dose to skin using TLD of several radiodiagnostic studies in San Jose, Costa Rica; Medicion de dosis a piel utilizando TLD de varios estudios radiodiagnosticos en San Jose, Costa Rica

    Energy Technology Data Exchange (ETDEWEB)

    Mora, P. [Laboratorio de Fisica Nuclear Aplicada, Escuela de Fisica, Universidad de Costa Rica, San Jose (Costa Rica)

    1998-12-31

    It is quantified the radiation doses on skin for several radiodiagnostic studies in patients of the Calderon Guardia Hospital in San Jose, Costa Rica at the period October 1997-September 1998 using thermoluminescent dosemeters TLD 100. The crystals receive the decoction standard procedures and they are arranged at the middle of the irradiation field. For a total of 973 radiodiagnostic studies it was found that the dose on skin in mGy are: 2.09 for thorax AP/AP, 5.33 for thorax LAT, 5.35 for skull AP/PA, 2.98 for skull LAT, 10.74 for abdomen, hips and pelvis, 6.20 for spines AP, 9.35 for spines LAT, 11.48 for lumbar columns AP, 29.99 for lumbar columns LAT and 6.87 for intravenous skin diagrams (first plate ap). It is produced thus the first reference bank for the national hospitals, which is compared with the orientation levels of doses for IAEA. Recommendations to diminish the collective doses through quality control programs are discussed, taking as goal to have got radiographs of excellent diagnostic quality, but with the less possible doses. (Author)

  12. Response of TLD-100 LiF dosimeters for X-rays of low energies; Respuesta de dosimetros de TLD-100 de LiF para rayos X de bajas energias

    Energy Technology Data Exchange (ETDEWEB)

    Bonzi, E. V.; Mainardi, R. T. [Universidad Nacional de Cordoba, Facultad de Matematica, Astronomia y Fisica, Av. Haya de la Torre y Av. Medina Allende s/n, Ciudad Universitaria, X5016LEA Cordoba (Argentina)

    2011-10-15

    In diverse practical applications as the existent in radiological clinics, industrial facilities and research laboratories, the solid state dosimeters are used for the measure of the different types of ionizing radiations. At the present time dosimeters are manufactured with different types of materials that present thermoluminescent properties, to the effects of determining the absorbed radiation dose. Under these conditions, the radiation dose is determined integrated in all the range of energies of the beam of X-rays, since it assumes that the response of these dosimeters is lineal with the energy of the photons or radiant particles. Because interest exists in advancing in the development of a determination method in the way of the X-rays spectrum emitted by a tube of those used in diagnostic or therapy, we have measured the response of TLD-100 LiF dosimeters for low energies, minor at 60 keV, for a several group of these dosimeters. (Author)

  13. Experimental determination of the photon-energy dependent dose-to-water response of TLD600 and TLD700 (LiF:Mg,Ti) thermoluminescence detectors

    Energy Technology Data Exchange (ETDEWEB)

    Schwahofer, Andrea [Vivantes Clinic Neukoelln, Berlin (Germany). Dept. of Radiation Therapy; German Cancer Research Center, Heidelberg (Germany). Medical Physics in Radiation Therapy; Feist, Harald [Munich Univ. (Germany). Dept. of Radiation Therapy; Georg, Holger [PTW Freiburg (Germany). Calibration Lab.; Haering, Peter; Schlegel, Wolfgang [German Cancer Research Center, Heidelberg (Germany). Medical Physics in Radiation Therapy

    2017-05-01

    The aim of this study has been the experimental determination of the energy dependent dose-to-water response of TLD600 and TLD700 thermoluminescent detectors (Harshaw) in X-ray beams with mean photon energies from about 20 to 200 keV in comparison with {sup 60}Co gamma rays and 6 MV X-rays. Experiments were carried out in collaboration with the German secondary standard laboratory PTW Freiburg. The energy dependent relative responses of TLD600 and TLD700 thermoluminescence detectors were determined at radiation qualities between 30 kV{sub p} and 280 kV{sub p}. The overall uncertainty of the measured values was characterized by standard deviations varying from 1.2 to 3%. The present results agree with previous studies on the energy dependent dose-to-water response of TLD100. As an application example, the results were used to measure doses associated with X-ray imaging in image-guided radiotherapy.

  14. Comparison of responses of thermoluminescent dosemeters irradiated by soft x-rays at very low and very high dose rate levels

    International Nuclear Information System (INIS)

    Pietrikova-Farnikova, M.; Krasa, J.; Juha, L.

    1994-01-01

    Recent great progress in construction and application of bright sources of soft X-rays gave a strong impetus for the development of methods of their dosimetric diagnostics. The soft X-ray sources are primarily represented by synchrotron radiation sources and by sources based on laser-produced plasma, including X-ray lasers. Their characteristics spread over a very wide region of photon energies, peak and average powers and densities. From our preliminary experiments it follows that thermoluminescent dosemeters can serve as a suitable tool for the determination of these characteristics. Problem lies in the fact that routine use of the thermoluminescent dosemeters for the dosimetry of soft X-rays requires their spectral calibration, which can be carried out with low peak power sources (synchrotron radiation and radionuclide sources). On the contrary, many important sources, especially these based on laser-produced plasmas, exhibit a very high peak power, i.e. dosemeters are irradiated at extremely high dose rate. In comparative experiments carried out with laser-produced plasmas and radionuclides using TLD 200 (CaF 2 :Dy) and GR 200A (LiF:Mg,Cu,P) it was satisfactorily proven that total thermoluminescent signals are independent of the dose rate. Dependence of glow curve shapes on the dose, dose rate and photon energy were equally determined

  15. Intercomparison program of personal dosemeters in the Argentine Republic

    International Nuclear Information System (INIS)

    Gregori, B.N.; Papadopulos, S.B.; Kunst, J.J.

    1998-01-01

    During 1997, under the auspices of the Nuclear Regulatory Authority (ARN), its was held the third exercise of intercomparison of laboratories of personal dosimetry. The dosemeters were irradiated in X-ray beams ISO quality W60, W110, W200 and gamma sources cesium 137 and cobalt 60. The irradiation were performed kerma free in air and in phantom in order to study the capacity to evaluate both conditions. An extent range of doses (low-high) have been given 0.3 mSv- 20mSv in order to determine the operative performance o each laboratory. Over 19 laboratories of Argentina, participated 13 (65%) and finished the intercomparison 12 (60%) of them. The systems of dosimetry detection were based on film and TLD. During this intercomparison as inquiry about several items related with the laboratories have been made. In this work are shown the individual laboratory results of the intercomparison related with the acceptance curve criteria ICRP 60 and 55. (author)

  16. Characterization of TLD-100 micro-cubes for use in small field dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Peña-Jiménez, Salvador, E-mail: zoid-9861@yahoo.com.mx; Gamboa-deBuen, Isabel, E-mail: gamboa@nucleares.unam.mx [Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Av. Universidad 3000, 04510 DF (Mexico); Lárraga-Gutiérrez, José Manuel, E-mail: jose.larraga.gtz@gmail.com, E-mail: amanda.garcia.g@gmail.com; García-Garduño, Olivia Amanda, E-mail: jose.larraga.gtz@gmail.com, E-mail: amanda.garcia.g@gmail.com [Laboratorio de Física Médica, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Av. Insurgentes Sur 3877, 14269 DF (Mexico)

    2014-11-07

    At present there are no international regulations for the management of millimeter scale fields and there are no suggestions for a reference detector to perform the characterization and dose determination for unconventional radiation beams (small fields) so that the dosimetry of small fields remains an open research field worldwide because these fields are used in radiotherapy treatments. Sensitivity factors and reproducibility of TLD-100 micro-cubes (1×1×1 mm3) were determinate irradiating the dosimeters with a 6 MV beam in a linear accelerator dedicated to radiosurgery at the Instituto Nacional de Neurología y Neurocirugía (INNN). Thermoluminescent response as a function of dose was determined for doses in water between 0.5 and 3 Gy and two field sizes (2×2 cm2 and 10×10 cm2). It was found that the response is linear over the dose range studied and it does not depend on field size.

  17. Performance tests on the NRPB thermoluminescent dosemeter

    CERN Document Server

    Shaw, K B

    1977-01-01

    Performance tests on the thermoluminescent dosemeter, designed at NRPB for use in the automated personal dosimetry system, are described. An ultra-thin lithium borate dosemeter has been developed for skin absorbed dose measurement. The X-ray, gamma-ray and beta-ray energy response of the dosemeter has been investigated and the angular response for the dosemeter has been examined. The annealing, read-out and stabilisation procedures for the dosemeter are described.

  18. Environmental gamma-ray dose measurements with thermoluminescence dosemeters (TLD) and environmental radiation characteristics

    International Nuclear Information System (INIS)

    Kanematsu, Seiko

    1999-01-01

    It is important to evaluate environmental gamma-ray exposure both at work and home in order to assess people's collective dosages. Environmental gamma radiation was measured for air-absorbed dose with a thermoluminescence dosemeter at various points in the workplace and Ningyotoge, and workplace radiation characteristics were analyzed. From the results, the public dose due to gamma rays generated artificially was assessed to be sufficiently lower than the annual limit. For indoor environments of the workplace, the maximum dosage rate among measured values was 97 nGy/h and the minimum value was 70 nGy/h, the average over one year was 83 nGy/h. The average annual outdoor dosage for a year was 82 nGy/ h. In Ningyotoge, the maximum was 103 nGy/h, minimum 60 nGy/h, and average 88 nGy/h. These values depend on the nature of the soil and weather factors, showing higher values in the summer than in the winter in the workplace. There was no significant difference in the dosage rate in houses and the workplace. (author)

  19. Fast neutron sensitivity of polymer dosemeters

    International Nuclear Information System (INIS)

    Harper, M.W.; Pearson, D.W.; Moran, P.R.

    1975-01-01

    The responses of polymer thermocurrent dosemeters to fission spectrum and 14 MeV neutrons were measured. The dosemeters are in the form of disks 1 cm diam by 0.5 mm thick. Relative to Cobalt 60 gamma responses, teflon PTFE dosemeters show a 6 percent response to 14 MeV neutrons and a 5 percent response to fission neutrons on a tissue rad basis. Polymethylpentene dosemeters show a 49 percent response to 14 MeV neutrons and a 40 percent response to fission neutrons on a tissue rad basis when provided with adequate recoil proton buildup. The sensitivity of these dosemeters is limited to neutron doses greater than 10 rads by spurious background currents

  20. Quality control for dosemeters

    International Nuclear Information System (INIS)

    Di Prinzio, R.

    1988-01-01

    Several tests and intercomparison of the secondary standard dosemeter calibration in Rio de Janeiro are described. Periodical tests, such as leakage current and the comparison between the secondary standard dosemeter in Rio de Janeiro e Sao Paulo are shown. (E.G.) [pt

  1. Measure of the attenuation curve of a beam of X-rays with TLD-100 dosimeters of LiF

    International Nuclear Information System (INIS)

    Bonzi, E. V.; Mainardi, R. T.; Germanier, A.; Delgado, V.

    2011-10-01

    The attenuation curve of a beam of X-rays represents the beam intensity in function of the attenuator thickness interposed between the source and the detector. To know with the major possible precision the attenuation curve is indispensable in procedures of spectral reconstruction. Their periodic measuring also offers valuable information on the correct operation of a tube of X-rays, diagnostic or therapy, when not have a specific detector for that activity. In this work was measured the attenuation curve of a tube of X-rays operated to 50 kV and 0.5 ma, using existent elements in any diagnostic or therapy laboratory with radiations. In the measures commercial aluminum foil was used, bent until 24 times and thermoluminescent dosimeters TLD 100 - LiF. Also, for comparison, was measured this attenuation curve with an ionization chamber brand Capintec model 192. Was determined by X-rays fluorescence the composition of the aluminium foil, since the present elements in the alloy can to affect the form of the attenuation curve. It is interesting to observe that these elements are in very low proportion (ppm) that they do not alter the attenuation capacity of the pure aluminium. Finally in a precision balance we weigh a big piece (30 cm x 100 cm) of aluminium foil and we obtained the thickness in g/c m2. It is possible to obtain attenuation curves of a beam of X-rays, with a high precision procedure and reproducibility. The use of TLD-100 dosimeters of LiF or similar makes that this activity was also quick and simple. (Author)

  2. Measurement of dose to skin using TLD of several radiodiagnostic studies in San Jose, Costa Rica

    International Nuclear Information System (INIS)

    Mora, P.

    1998-01-01

    It is quantified the radiation doses on skin for several radiodiagnostic studies in patients of the Calderon Guardia Hospital in San Jose, Costa Rica at the period October 1997-September 1998 using thermoluminescent dosemeters TLD 100. The crystals receive the decoction standard procedures and they are arranged at the middle of the irradiation field. For a total of 973 radiodiagnostic studies it was found that the dose on skin in mGy are: 2.09 for thorax AP/AP, 5.33 for thorax LAT, 5.35 for skull AP/PA, 2.98 for skull LAT, 10.74 for abdomen, hips and pelvis, 6.20 for spines AP, 9.35 for spines LAT, 11.48 for lumbar columns AP, 29.99 for lumbar columns LAT and 6.87 for intravenous skin diagrams (first plate ap). It is produced thus the first reference bank for the national hospitals, which is compared with the orientation levels of doses for IAEA. Recommendations to diminish the collective doses through quality control programs are discussed, taking as goal to have got radiographs of excellent diagnostic quality, but with the less possible doses. (Author)

  3. Ionizing radiation source detection by personal TLD

    International Nuclear Information System (INIS)

    Marinkovic, O.; Mirkov, Z.

    2002-01-01

    The Laboratory for personal dosimetry has about 3000 workers under control. The most of them work in medicine. Some institutions, as big health centers, have different ionizing radiation sources. It is usefull to analyze what has been the source of irradiation, special when appears a dosimeter with high dose. Personal dosimetry equipment is Harshaw TLD Reader Model 6600 and dosimeters consist of two chips LiF TLD-100 assembled in bar-coded cards which are wearing in holders with one tissue-equivalent filter (to determine H(10)) and skin-equivalent the other (to determine H(0.07)). The calibration dosimeters have been irradiated in holders by different sources: x-ray (for 80keV and 100keV), 6 0C o, 9 0S r (for different distances from beta source) and foton beem (at radiotherapy accelerator by 6MeV, 10MeV and 18MeV). The dose ratio for two LiF cristals was calculated and represented with graphs. So, it is possible to calculate the ratio H(10)/H(0.07) for a personal TLD and analyze what has been the source of irradiation. Also, there is the calibration for determination the time of irradiation, according to glow curve deconvolution

  4. Self-indicating radiation alert dosemeter (SIRAD)

    International Nuclear Information System (INIS)

    Riel, G. K.; Winters, P.; Patel, G.; Patel, P.

    2006-01-01

    In an event of a nuclear or dirty bomb explosion and a radiological accident, there is a need for self-indicating instant radiation dosemeter for monitoring radiation exposure. The self-indicating instant radiation alert dosemeter (SIRAD) is a credit card size radiation dosemeter for monitoring ionising radiation from a few hundredths of a Gray to a few Gray. It is always active and is ready to use. It needs no battery. The dosemeter develops colour instantly upon exposure, and the colour intensifies with dose. It has a colour chart so that the dose on the active element may be read by matching its colour with the chart that is printed next to it on the card. However, in this work, the dose is measured by the optical density of the element. The dosemeter cannot be reset. The response changes by 3 y at room temperature. It contains no hazardous materials. The dosemeter would meet the requirements of instantly monitoring high dose in an event of a nuclear or dirty bomb explosion or a radiation accident. (authors)

  5. Self-indicating radiation alert dosemeter (SIRAD).

    Science.gov (United States)

    Riel, Gordon K; Winters, Patrick; Patel, Gordhan; Patel, Paresh

    2006-01-01

    In an event of a nuclear or dirty bomb explosion and a radiological accident, there is a need for self-indicating instant radiation dosemeter for monitoring radiation exposure. The self-indicating instant radiation alert dosemeter (SIRAD) is a credit card size radiation dosemeter for monitoring ionising radiation from a few hundredths of a Gray to a few Gray. It is always active and is ready to use. It needs no battery. The dosemeter develops colour instantly upon exposure, and the colour intensifies with dose. It has a colour chart so that the dose on the active element may be read by matching its colour with the chart that is printed next to it on the card. However, in this work, the dose is measured by the optical density of the element. The dosemeter cannot be reset. The response changes by 3 y at room temperature. It contains no hazardous materials. The dosemeter would meet the requirements of instantly monitoring high dose in an event of a nuclear or dirty bomb explosion or a radiation accident.

  6. The characteristics of CaF2:Tm crystals (TLD-300) irradiated by electromagnetic radiation

    International Nuclear Information System (INIS)

    Ben-Shachar, B.; Yona, S.; Laichter, Y.; German, U.; Weiser, G.

    1985-09-01

    The main characteristics of the CaF 2 :Tm crystals (TLD-300), as a dosimeter, were measured: the glow curve, sensitivity, linearity, fading and energy dependence for photons, and compared to those of LiF (TLD-100) and CaF 2 :Dy (TLD-200). It was found that CaF 2 :Tm can be used for environmental dosimetry by reading the crystals after four days. (Author)

  7. Response of TLD-100 LiF dosimeters for X-rays of low energies

    International Nuclear Information System (INIS)

    Bonzi, E. V.; Mainardi, R. T.

    2011-10-01

    In diverse practical applications as the existent in radiological clinics, industrial facilities and research laboratories, the solid state dosimeters are used for the measure of the different types of ionizing radiations. At the present time dosimeters are manufactured with different types of materials that present thermoluminescent properties, to the effects of determining the absorbed radiation dose. Under these conditions, the radiation dose is determined integrated in all the range of energies of the beam of X-rays, since it assumes that the response of these dosimeters is lineal with the energy of the photons or radiant particles. Because interest exists in advancing in the development of a determination method in the way of the X-rays spectrum emitted by a tube of those used in diagnostic or therapy, we have measured the response of TLD-100 LiF dosimeters for low energies, minor at 60 keV, for a several group of these dosimeters. (Author)

  8. Principle and use of dosemeters

    International Nuclear Information System (INIS)

    Genet, S.; Ribaud, I.

    1997-01-01

    The institute of nuclear physics of Orsay is accepted by the Ministry of Labour to insure the surveillance of workers individual external exposure against the danger of ionizing radiations and to execute monitoring of radiation protection. The dosemeters studied in this report are the photographic film dosemeters ( for x rays, gamma rays and beta - rays), the trace detectors (fast neutrons) and the radio thermo luminescent dosemeters. For each type, the principle and how to use it are given. (N.C.)

  9. Evaluation of the directional dose equivalent H,(0.07) for ring dosemeters

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Tovar M, V.M.

    2006-01-01

    The personnel dosimetry laboratory (LDP) of the Metrology department received an user's of radiation beta application that incidentally had irradiated 14 couples of ring dosemeters for extremities of the type TLD-100 given by the LDP. This sample of 14 couples of rings tentatively it was irradiated in the months of July-August of the year 2004, and he requested in an expedite way the evaluation of the received dose equivalent. The LSCD builds two calibration curves in terms of the directional dose equivalent H'(0.07) using two sources patterns of 90 Sr- 90 Y for beta radiation: one of 74 MBq and another of 1850 MBq with traceability to the PTB. The first curve in the interval of 0 to 5 mSv, the second in the range of 5 to 50 mSv, taking into account effects by positioned of the rings in the phantom. Both calibration curves were validated by adjustment lack, symmetry of residuals and normality of the same ones. It is evaluated and analyzing the H'(0.007) for these 14 couples of rings using the Tukey test of media of a single road. It was found that the H , its could be classified in 4 groups, and that the probability that its has irradiated in a random way it was smaller to the level at α = 0.05. (Author)

  10. Dosimetric analysis using glasses TLD-100 Lif; Mg; TI for the optimization of the quality control programs in radio surgery stereo tactic

    International Nuclear Information System (INIS)

    Maldonado, J. C; Plazas, M. C.; Dussan, R.; Conrado, Z.; Pena, G.; Jimenez, E.; Hakim, F.; Bermudez, S.

    2001-01-01

    The conditions of Stereo Tactic Radio Surgery treatments are simulated by means of the use of thermo luminescent glasses TLD-100 LiF; Mg; Ti placed in mannequins, to demonstrate that the doses received by the patients, either in the fractioned or in the mono fractioned techniques, are over the 500cGy, making urgent the use of a reliable dosimetric method [es

  11. The effect of sample/planchet geometry and temperature resolution on the reproducibility of glow curve shapes and precision of dose measurement in LiF-TLD-100 thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Sibony, D.; Horowitz, Y.; Oster, L.

    2014-01-01

    The effect of accurate positioning of TLD-100 samples in the center of the reader planchet on precision and kinetic parameters was investigated. Significant improvement in precision is obtained by careful positioning of the sample in the center of the planchet, by as much as 40%, 20% and 30% using different methods of glow curve analysis to estimate the intensity of the TL signal. - Highlights: • The effect of accurate positioning of TLD-100 samples on precision and kinetic parameters was investigated. • Significant improvement in precision was obtained. • Significant improvement in the calculation of the kinetic parameters of individual peaks was achieved. • The optimum protocol involves a depression matched to the size of the sample was developed

  12. Development trends of radiophotoluminescent glass dosemeter

    International Nuclear Information System (INIS)

    Ikegami, T.

    2004-01-01

    RPL glass dosemeter has been recently recognized to have a good performance as accumulation dosemeter and has been routinely used for personal dosimetry and environmental radiation monitoring. Furthermore, its applicable field is being extending to medical radiation measurement. The history of RPL glass dosemeter is very long. It was born in USA in 1950s and after that it was improved in Japan. And it was used as personal dosemeter in 1970s. But, in those days, RPL glass dosemeter was not suitable to low dose measurement due to some handling problems. So, its use had been reduced gradually. The author has broken through any past problems, by mainly realizing the pulsed UV excitation method. In this paper, the development history, principle and features, and the development good results of the pulsed UV excitation method are summarized, including the introduction of recent RPL glass dosimetry products. (author)

  13. Response of electret dosemeter to slow neutrons

    International Nuclear Information System (INIS)

    Ghilardi, A.J.P.; Pela, C.A.; Zimmerman, R.L.

    1987-01-01

    The response of electret dosemeter to slow neutrons exposure is cited, mentioning the preparation and the irradiation of dosemeter with Am-Be source. Some theory considerations about the response of electret dosemeter to slow and fast neutrons are also presented. (C.G.C.) [pt

  14. Optical readout method for solid-state dosemeters

    International Nuclear Information System (INIS)

    McDonald, J.C.; Eichner, F.N.; Stahl, K.A.; Miller, S.D.

    1986-07-01

    The readout of solid-state dosemeters is usually accomplished by heating to produce thermoluminescence. This technique has several disadvantages including stressing the dosemeter crystals, melting Teflon enclosures, and destroying the thin dosemeters designed for beta particle measurements. An optical readout method is being developed to avoid these difficulties. Standard dosemeters were irradiated to a dose of approximately 0.02 Sv with 137 Cs gamma rays. The dosemeters were then irradiated with light produced by a high-intensity xenon lamp. Various wavelength bands, from the ultraviolet through the visible and to the near-infrared, were used. The degree of trap emptying was found to be proportional to the total optical power incident. With the intensities used in the preliminary experiments, over 90% trap emptying was achieved. This new technique will prove useful for dosemeters that are encased in plastic for automatic processing. The details of this optical readout method, along with some possible applications in neutron and beta dosimetry are described. 7 refs., 3 figs

  15. EDEL: ENEA dosemeter for eye lens

    International Nuclear Information System (INIS)

    Ferrari, Paolo; Mariotti, Francesca; Campani, Lorenzo

    2016-01-01

    Since the publication of International Commission on Radiological Protection statement in 2011 on tissue reaction, eye lens radiation protection played an important role in exposed personnel dosimetry. For this reason, the Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA) Individual Monitoring Service decided to study a prototype to fulfil specific requests (e.g. for survey in interventional department and intercomparisons). On the basis of such preliminary investigation, a new eye lens dosemeter was developed. The new dosemeter, named EDEL (ENEA Dosemeter for Eye Lens), was characterised in terms of H p (3), the operational quantity related to eye lens monitoring. The investigation was performed experimentally and optimised using the Monte Carlo MCNP6 code. The new prototype was thought to fulfil two main requests: the reliability of the dosimetric data and the portability of the dosemeter itself. The new dosemeter will soon be supplied to the collaborating hospitals for workplace test measurements. (authors)

  16. Technical specification of the NRPB Nuclear Emulsion Dosemeter

    International Nuclear Information System (INIS)

    Bartlett, D.T.; Bird, T.V.

    1978-08-01

    This document is a formal specification of the NRPB Nuclear Emulsion Dosemeter. The dosemeter specified in this report replaces the NRPB Fast Neutron Personal Dosemeter specified in NRPB-R50. (author)

  17. Characterization of {sup 6}LiF:Mg,Cu,P (TLD-600 H) estimate of E, b and s parameters

    Energy Technology Data Exchange (ETDEWEB)

    Andres, P. A., E-mail: andresp@cab.cnea.gov.ar [Centro Atomico Bariloche, Division Proteccion Radiologica / CNEA, Av. E. Bustillo Km 9.5, R8402AGP San Carlos de Bariloche (Argentina)

    2015-10-15

    LiF:Mg,Cu,P dosemeters are useful for low-dose measurements because of its high sensitivity compared to the LiF:Mg,Ti dosemeters. {sup 7}LiF:Mg,Cu,P have been used for environmental dosimetry in Bariloche Atomic Centre for almost a decade. Since {sup 6}LiF:Mg,Cu,P dosemeters were intended to be used for X ray diagnosis dosimetry in neonatology, they had to be characterized first. The main goal of measuring and analyzing Tl glow curves is the extraction of some parameters that can be used to describe the Tl process in the material. This job focused on the estimation of the activation energy E for the Tl traps, the frequency factor s and the order of kinetics b of the Tl process. Furthermore, the most appropriate time-temperature profile (Ttp) was determined as well as the annealing temperature and time, which resulted being 240 degrees C for 10 minutes. The Ttp used was 140 degrees C for 10 seconds, a heating rate of 20/s until 240 degrees C, remaining at this temperature for 20 seconds, and then an exponential cooling until 50 degrees C. After applying the whole glow-peak method for different orders of kinetic, and the Kitis equation assuming a first order kinetics, the values obtained were: E = (1.066 ± 0.025) eV, as a weighted average of both methods, and a frequency factor s = (3.57 ± 1.56) E-10 s{sup -1} again as a weighted average of both methods. In both cases a first order kinetics (b = 1) was assumed. The dosemeters were irradiated with a calibrated {sup 137}Cs source and read with a Harshaw TLD{sup TM} Model 3500 reader resulting in a minimum detectable dose of about 20 μGy. (Author)

  18. Thermoluminescent response of LiF before variation of the heating rate

    International Nuclear Information System (INIS)

    Barrios, R.; Avila, O.

    2003-01-01

    Comparisons of glow curves of lithium fluoride dosemeters TLD-100 measured to two heating rates with the purpose of quantifying the change in the temperature of the peaks 5 and 7 for the thermoluminescent reader equipment Harshaw 4000 of the thermoluminescence laboratory of the ININ were carried out. (Author)

  19. Thermoluminescent response of LiF before variation of the heating rate; Respuesta termoluminiscente de LiF ante variacion de la tasa de calentamiento

    Energy Technology Data Exchange (ETDEWEB)

    Barrios, R. [Facultad de Quimica, UAEM, 50000 Toluca, Estado de Mexico (Mexico); Avila, O. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    Comparisons of glow curves of lithium fluoride dosemeters TLD-100 measured to two heating rates with the purpose of quantifying the change in the temperature of the peaks 5 and 7 for the thermoluminescent reader equipment Harshaw 4000 of the thermoluminescence laboratory of the ININ were carried out. (Author)

  20. Selected references on thermoluminescent dosemeters for personnel monitoring

    International Nuclear Information System (INIS)

    Lawson, Helen

    1976-08-01

    This bibliography contains references on: specific thermoluminescent dosemeters used for personnel dosimetry; comparisons of thermoluminescent and other dosemeters for personnel monitoring and read-out apparatus for thermoluminescent dosemeters. An appendix contains selected foreign language references. (author)

  1. Manufacture of thermoluminescent dosimeter of LiF(Mg) by sintherization technique

    International Nuclear Information System (INIS)

    Borges, V.; Elbern, A.W.

    1984-01-01

    A technique to produce solid state dosemeters, that can be used in personal dosimetry, using LiF powder is described. Many differents baths of cold compacted and sinterized dosimeters were investigated as a function of the dopant concentration and the sinterization time. Some termoluminescent characteristics were measured, and compared to those of the extruded TLD-100 dosemeters, which are used as an international reference. The experimental methodology and the obtained results, with their respective analyses, are the subject of this paper. (M.A.C.) [pt

  2. Calibrations of pocket dosemeters using a comparison method

    International Nuclear Information System (INIS)

    Somarriba V, I.

    1996-01-01

    This monograph is dedicated mainly to the calibration of pocket dosemeters. Various types of radiation sources used in hospitals and different radiation detectors with emphasis on ionization chambers are briefly presented. Calibration methods based on the use of a reference dosemeter were developed to calibrate all pocket dosemeters existing at the Radiation Physics and Metrology Laboratory. Some of these dosemeters were used in personnel dosimetry at hospitals. Moreover, a study was realized about factors that affect the measurements with pocket dosemeters in the long term, such as discharges due to cosmic radiation. A DBASE IV program was developed to store the information included in the hospital's registry

  3. Environmental monitoring system with TLD; Sistema de monitoreo ambiental con TLD

    Energy Technology Data Exchange (ETDEWEB)

    Aguerre, L.; Carelli, J.; Gregori, B. [Autoridad Regulatoria Nuclear Argentina (Argentina)]. e-mail: laguerre@cae.arn.gov.ar

    2006-07-01

    Presently work the methodology used by the Laboratory of Thermoluminescent Dosimetry (TLD) of the Nuclear Regulatory Authority (RNA) to gauge it system of environmental monitoring in function of the media absorbed dose rate in free air and the environmental dose equivalent, H{sup *}(10), according to the recommendation ICRU Report 47 is described. It was studied the response of the environmental dosemeter (DA) in fields of photonic radiation of energies W60, Wl 10, W200 and {sup 137} Cs. The irradiations were carried out following the recommendations of the standard ISO:4037. It was analyzed the response in the DA of the detectors LiF: Mg, Ti and CaF{sub 2}: Dy for the different radiation qualities and the relative response at {sup 137} Cs of both. The methodology used in the evaluation of the dose includes: the correction of the readings of both detectors by fading, gotten experimentally, the witness of transfers, the energy answer and the value of the zero. The dose is calculated applying the average pondered in uncertainty of the dose obtained for each type of detector. Its were analyzed and calculated the uncertainties that affect to the measurement following the recommendation of the Argentine standard IRAM 35050. The detection limit of the absorbed dose rate in free air of this system it is 3.5 n Gy/h for a period of sampling of 3 months. With this detection limit environmental dose equivalent rates of the order of 70 n Sv/h are measured with an expanded uncertainty of the order of 10% with a cover factor k = 2. (Author)

  4. Electret dosemeter for beta radiation

    International Nuclear Information System (INIS)

    Campos, L.L.; Caldas, L.V.E.; Mascarenhas, S.

    The response characteristics of an electret dosemeter for beta radiation are studied. Experiments were performed using different geometries and walls, and it was verified for which geometry the dosemeter sensitivity is greater. Sources of 90 Sr - 90 Y, 204 Tl and 85 Kr were used in the experiments. (I.C.R.) [pt

  5. Comparing different error-conditions in film dosemeter evaluation

    International Nuclear Information System (INIS)

    Roed, H.; Figel, M.

    2007-01-01

    In the evaluation of a film used as a personal dosemeter it may be necessary to mark the dosemeters when possible error-conditions are recognised, such as errors that have an influence on the ability to make a correct evaluation of the dose value. In this project a comparison has been carried out to examine how two individual monitoring services, IMS [National Inst. of Radiation Hygiene (Denmark) (NIRH) and National Research Centre for Environment and Health (Germany) (GSF)], from two different EU countries mark their dosemeters. The IMS are different in size, type of customers and issuing period, but both use films as their primary dosemeters. The error-conditions examined are dosemeters exposed to moisture or light, contaminated dosemeters, films exposed outside the badge, missing filters in the badge, films inserted incorrectly in the badge and dosemeters not returned or returned too late to the IMS. The data are collected for the year 2003 where NIRH evaluated ∼50,000 and GSF ∼1.4 million film dosemeters. The percentage of film dosemeters is calculated for each error-condition as well as the distribution among eight different employee categories, i.e. medicine, nuclear medicine, nuclear industry, industry, radiography, laboratories, veterinary and others. It turned out, that incorrect insertion of the film in the badge was the most common error-condition observed at both IMS and that veterinarians, as the employee category, generally have the highest number of errors. NIRH has a significantly higher relative number of dosemeters in most error-conditions than GSF, which perhaps reflects that a comparison is difficult due to different systemic and methodical differences between the IMS and countries, e.g. regulations and monitoring programs etc. Also the non-existence of a common categorisation method for employee categories contributes to make a comparison like this difficult. (authors)

  6. Application of the Cavity theory in the calibration of the powder TLD-100 for energies of 60 Co, 137 Cs, 192 Ir and RX 50, 250 k Vp

    International Nuclear Information System (INIS)

    Loaiza C, S.P.; Alvarez R, J.T.

    2006-01-01

    A powder lot TLD-100 (LiF:Mg,Ti) in absorbed dose terms in water D w for the following radiation sources: 60 Co, 137 Cs and RX 50 and 250 k Vp is calibrated; to continuation is made a lineal interpolation of the TLD response in function of the effective energy of the sources to calibrate a source of 192 Ir. The calibration of those fields in D w are carried out with aid of the Bragg-Gray cavity theory, the one which finds implicit in the following protocols: IAEA-TRS 398 for the 60 Co and the AAPM TG61 for X Rays of 50 and 250 k Vp. Additionally the AAPM protocol TG43 to determine the D w in function of the kerma intensity S k in the case of the 137 Cs is used. The calibration curves for the response of the TLD-100 R TLD vs D w , corresponding to each one of the sources already mentioned are constructed. The R TLD vs D w by least heavy square by means of a second order polynomial that corrects the supralineality of the response is adjusted. The curves are validated by lack of LOF adjustment and by the Anderson Darling normality test. Later the factors of sensitivity (F s ) for the sources of 192 Ir: Micro Selectron and Vari Source are interpolated, used respectively in the A and B hospitals for treatments of brachytherapy of high dose rate (HDR), the expanded uncertainties associated to the D w and F s are also determined. Finally, an acrylic phantom and a couple of capsules are already sent to the hospitals mentioned, to verify a nominal D w of 2 Gy, in a case an underestimate in 5.5% in the imparted D w and in other an overestimation in a range of -1.5 to -8.0% was obtained. The obtained results in this work establish the bases for the development of a national dosimetric quality control program for brachytherapy of HDR with sources of 192 Ir. (Author)

  7. Traceability of a panoramic gamma irradiator using different TLD systems as transfer instruments

    International Nuclear Information System (INIS)

    Romero, A.M.; Saez, J.C.

    1994-01-01

    This work shows the calibration in terms of the new operational radiological quantities Hp(10) and H*(10) for different TLD systems (Harshaw TLD-100 and Panasonic UD-802) used in personal and environmental monitoring. The irradiations were performed in the Spanish Reference Laboratory in radiation protection levels, managed by the CIEMAT Metrology of ionizing radiations Unit. With these data, different calibrations of a panoramic gamma irradiator in terms of the radiological quantity for unit of time were established, providing the traceability of the irradiator to the Reference Laboratory using the corresponding TLD systems as transfer instruments. (Author) 9 refs

  8. Traceability of a panoramic gamma irradiator using different TLD systems as transfer Instruments

    International Nuclear Information System (INIS)

    Romero, A. M.; Saez, J. C

    1994-01-01

    This work shows the calibration in terms of the new operational radiological quantities Hp (10) and H(10) for different TLD systems (Harshaw TLD-100 and Panasonic UD-002) used in personal and environmental monitoring. The irradiations were performed in the Spanish Reference Laboratory in radiation protection levels, managed by the CIEMAT Metrology of ionizing radiations Unit. With those data, different calibrations of a panoramic gamma irradiator in terms of the radiological quantity for unit of time were established, providing the traceability of the irradiator to the Reference Laboratory using the corresponding TLD systems as transfer instruments. (Author) 9 refs

  9. Coincidence in the dose estimation in a OEP by different methods

    International Nuclear Information System (INIS)

    Guerrero C, C.; Arceo M, C.; Brena V, M.

    2007-01-01

    The case of an apparent overexposure to radiation according to that indicated for the thermoluminescent dosemeter 81.59 mSv (TLD) of a occupationally exposed hard-working (POE), for that was practiced the study of biological dosimetry. The estimated dose was 0.12 Gy with which was proven the marked dose registration by the TLD dosemeter. It was concluded that both doses are the same ones. (Author)

  10. Coincidence in the dose estimation in a OEP by different methods; Coincidencia en la estimacion de dosis en un POE por diferentes metodos

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C.; Arceo M, C.; Brena V, M. [ININ, Km. 36.5, Carretera Mexico-Toluca, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: cgc@nuclear.inin.mx

    2007-07-01

    The case of an apparent overexposure to radiation according to that indicated for the thermoluminescent dosemeter 81.59 mSv (TLD) of a occupationally exposed hard-working (POE), for that was practiced the study of biological dosimetry. The estimated dose was 0.12 Gy with which was proven the marked dose registration by the TLD dosemeter. It was concluded that both doses are the same ones. (Author)

  11. Turismo y eficiencia: tendencias regionales

    Directory of Open Access Journals (Sweden)

    José Antonio Camacho Ballesta

    2002-01-01

    Full Text Available En este trabajo se analiza la evolución de la productividad de las actividades económicas relacionadas con el turismo, centrando el estudio en la Hostelería y restaurantes, durante el período comprendido entre 1965 y 1995, y su efecto sobre la productividad de los servicios destinados a la venta en las regiones españolas. La metodología utilizada incluye herramientas como el análisis envolvente de datos, los índices de Malmquist, y la descomposición de la eficiencia total en eficiencia intrasectorial y eficiencia de composición. Los resultados muestran que la eficiencia de composición en los servicios destinados a la venta ha mejorado a lo largo del período estudiado, consecuencia del crecimiento en el tamaño relativo de aquellas ramas más eficientes o de aquellas donde la eficiencia ha crecido más. El buen comportamiento de la eficiencia comparada de la rama Hostelería y restaurantes explica que la especialización regional en dicha rama se haya convertido en un elemento de mejora para la eficiencia de composición. El cambio productivo ha sido positivo en todo el período analizado excepto en los años 1979 y 1995, con una variación media anual del 3,1% y explicado, casi por completo por el cambio técnico. Las regiones que han experimentado los mayores cambios productivos positivos han sido Cataluña, Galicia, Extremadura, Valencia y Madrid.

  12. Passive neutron dosemeter with activation detector

    Energy Technology Data Exchange (ETDEWEB)

    Valero L, C.; Banuelos F, A.; Guzman G, K. A.; Borja H, C. G.; Hernandez D, V. M.; Vega C, H. R., E-mail: fermineutron@yahoo.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2011-10-15

    A passive neutron dosemeter with {sup 197}Au activation detector has been developed. The area dosemeter was made as a 20.5 {phi} x 20.5 cm{sup 2} polyethylene moderator, with a polyethylene pug where a {sup 197}Au foil can be located either parallel or perpendicular to moderator axis. Using Monte Carlo methods, with the MCNP5 code. With the fluence response and the fluence-to-equivalent dose conversion coefficients from ICRP-74, responses to H*(10) were also calculated, these were compared against responses of commercially available neutron area monitors and dosemeters. (Author)

  13. Comparison of characteristics of LiF:Mg,Ti e LiF:Mg,Cu,P thermoluminescent dosemeters; Comparacao das caracteristicas dos dosimetros termoluminescentes LiF:Mg,Ti e LiF:Mg,Cu,P

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, M.S.; Filipov, D., E-mail: dfilipov@utfpr.edu.br [Universidade Tecnologica Federal do Parana (UTFPR/DAFIS), Curitiba, PR (Brazil). Departamento Academicao de Fisica; Schelin, H.R. [Instituto de Pesquisa Pele Pequeno Principe (IPPPP), Curitiba, PR (Brazil)

    2014-07-01

    The aim of the current study was to compare the thermoluminescent dosimeters LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (MCP) data, which were acquired by the Federal Technological University - Parana. Tests were realized, for this purpose, such as: sensitivity (only one MCP TLD did not present results within the limit range), linearity (whose MCP result was better than the TLD-100 one), energy dependence (TLD-100 presented lower variation than MCP TLD) and reproducibility (whose TLD-100 results were better than the MCP ones). The results from both dosimeters show that these TLDs attend radiodiagnostic dosimetry criteria, however MCP had more satisfactory results. (author)

  14. The need for comparison of diagnostic dosemeters

    International Nuclear Information System (INIS)

    Kramer, H.M.

    1989-01-01

    One precondition for successfully implementing quality control in diagnostic radiology is that the measuring instruments used are of adequate quality. Among the measuring instruments used for quality control, dosemeters play a predominant role. Therefore it is essential to know the performance characteristics of a suitable dosemeter and to have information on the uncertainties and measurement errors found during acceptance testing. An outline will be given of the requirements on the accuracy of dosemeters. Such requirements have to address the task of the dosemeter and also take into account their technical feasibility. In order to gather information on the performance characteristics of field instruments, a programme for a European intercomparison has been developed which was carried out in 1988. The programme, together with its underlying ideas and its objectives, is presented in this paper. (author)

  15. A Modification of Gamma Surveymeter Dosemeter 3007A for Monitoring Use Ethernet by PLC T100MD Series

    International Nuclear Information System (INIS)

    Ikhsan Shobari; Subchan, M.; Syahrudin Yusuf; Sutomo Budihardjo

    2010-01-01

    It has been modified a gamma surveymeter Dosemeter 3007A. The Surveymeter represents analogous surveymeter, so that an interface for data acquisition is required. Acquisition system from surveymeter is added to the voltage amplifier module from 0 - 200 mV to 0 - 5 V. This voltage value will represent of doses 0 - 5 mR/hour. Hereinafter the analogous signal 0 - 5 V as signal of input to peripheral of PLC T100MD series. Data in the form of processed analogous signal presented at local display of PLC. For long distance monitoring, data have been sent to a computer from PLC by ethernet. After this modification, the surveymeter can be used to monitor from long distance. By using Internet Service Provider, monitoring can be done at any time and any where as long as network internet is available. (author)

  16. Digital dosimetry and personal and environmental monitoring assembly

    International Nuclear Information System (INIS)

    Cerovac, Z.; Radalj, Z.; Prlic, I.; Cerovac, H.

    1996-01-01

    Film+TLD and film or TLD Dosimetry have a certain delay in dose reporting, since the reports on occupational doses are usually available to the users within 40 days after the actual exposure. This is particularly important when the dose is received within the short-time interval or when the radiation source has some technical failures. For this reason, the additional monitoring is recommendable. The common Dosimetry service in Croatia is well established and the data available shows that over 80% of occupationally exposed persons are working in medical facilities, mainly with x-ray sources. Dosimetry services in the country are providing three types of dosemeters, film dosemeter badge, film+TLD dosemeter badge or plane TLD badge. We have decided to introduce the palette of digital pocket dosemeters to be used at different workplaces occupationally exposed to ionizing radiation. After the first experience with the ALARA 1G digital dosemeter it came out that this type of ionizing radiation measuring device is suitable for the various non-occupational purposes. After some technical improvement and with some telecommunication electronics this device is usable as a point environmental measuring station. This means that the probe of the record any change in normal environmental radiation field, send the data to the central station and to raise alarm if necessary. That is why we have made a prototype for environmental monitoring able to be connected to any kind of telecommunication net. (author)

  17. Environmental monitoring system with TLD

    International Nuclear Information System (INIS)

    Aguerre, L.; Carelli, J.; Gregori, B.

    2006-01-01

    Presently work the methodology used by the Laboratory of Thermoluminescent Dosimetry (TLD) of the Nuclear Regulatory Authority (RNA) to gauge it system of environmental monitoring in function of the media absorbed dose rate in free air and the environmental dose equivalent, H * (10), according to the recommendation ICRU Report 47 is described. It was studied the response of the environmental dosemeter (DA) in fields of photonic radiation of energies W60, Wl 10, W200 and 137 Cs. The irradiations were carried out following the recommendations of the standard ISO:4037. It was analyzed the response in the DA of the detectors LiF: Mg, Ti and CaF 2 : Dy for the different radiation qualities and the relative response at 137 Cs of both. The methodology used in the evaluation of the dose includes: the correction of the readings of both detectors by fading, gotten experimentally, the witness of transfers, the energy answer and the value of the zero. The dose is calculated applying the average pondered in uncertainty of the dose obtained for each type of detector. Its were analyzed and calculated the uncertainties that affect to the measurement following the recommendation of the Argentine standard IRAM 35050. The detection limit of the absorbed dose rate in free air of this system it is 3.5 n Gy/h for a period of sampling of 3 months. With this detection limit environmental dose equivalent rates of the order of 70 n Sv/h are measured with an expanded uncertainty of the order of 10% with a cover factor k = 2. (Author)

  18. New ISO standard - personnel photographic film dosemeters

    International Nuclear Information System (INIS)

    Brabec, D.

    1980-01-01

    The ISO Standard 1757 ''Personnel Photographic Film Dosemeters'', issued in June 1980, is briefly described. UVVVR's own dosemeter developed for use in the national film dosimetry service in Czechoslovakia is evaluated in relation to this ISO Standard. (author)

  19. Calibration procedures for mammography dosemeters in Poland

    International Nuclear Information System (INIS)

    Gwiazdowska, B.; Ulkowski, P.; Tolwinski, J.; Bulski, W.

    2002-01-01

    Breast cancer is the most frequent tumour in women and the effectiveness of the treatment depends dramatically on the early detection of the disease. That is the reason why in Poland the mammography control examinations are strongly supported by the Centre of Oncology. In Poland there are over 400 mammography units which account for about 300,000 examinations per year. An investigation performed by the Medical Physics Department of the Centre of Oncology in Warsaw at about 100 mammography facilities proved that in most cases the doses absorbed by the patients could be reduced without decrease of image quality. This is one of the reasons why the Polish Secondary Standard Dosimetry Laboratory (SSDL) dealing mainly with calibration of radiotherapy dosemeters is extending its activities and therefore new facilities and equipment adapted for calibration of mammographic dosemeters have been installed. The mammography dosimetry calibration equipment is permanently installed in the same laboratory room where the radiotherapy dosemeters are calibrated. A base of a mammography unit no longer in clinical use, together with its movable system has been adapted to handle ionization chamber holders. An X-ray tube with a 50 kV high frequency generator was also installed. The tube, a Varian type OEG-50-2, (designed for laboratory applications) with molybdenum anode of an anode angle 23,7 deg. and with a large focus, effective size approximately 5 mm 2 , has an inherent filtration of 0,25 mm beryllium. It is installed in a housing with 2mm lead shielding; a cone shaped beam is formed by a system of three collimators

  20. Response of electret dosemeter to slow neutrons

    International Nuclear Information System (INIS)

    Ghilardi, A.J.P.; Pela, C.A.; Zimmerman, R.L.

    1987-01-01

    The response of the electret dosemeter to exposition of slow neutrons is studied. Different external coatings are used on the dosemeter (polyethylene, alminium, polyethylene + boron, aluminium + boron) and exposure curves (with and without water) are compared. (M.A.C.) [pt

  1. NUCLEAR HEATING IN LIF DOSEMETERS IN A FUSION NEUTRON FIELD, TRIAL OF DIRECT COMPARISON OF EXPERIMENTAL AND SIMULATED RESULTS.

    Science.gov (United States)

    Pohorecki, Wladyslaw; Obryk, Barbara

    2017-09-29

    The results of nuclear heating measured by means of thermoluminescent dosemeters (TLD-LiF) in a Cu block irradiated by 14 MeV neutrons are presented. The integral Cu experiment relevant for verification of copper nuclear data at neutron energies characteristic for fusion facilities was performed in the ENEA FNG Laboratory at Frascati. Five types of TLDs were used: highly photon sensitive LiF:Mg,Cu,P (MCP-N), 7LiF:Mg,Cu,P (MCP-7) and standard, lower sensitivity LiF:Mg,Ti (MTS-N), 7LiF:Mg,Ti (MTS-7) and 6LiF:Mg,Ti (MTS-6). Calibration of the detectors was performed with gamma rays in terms of air-kerma (10 mGy of 137Cs air-kerma). Nuclear heating in the Cu block was also calculated with the use of MCNP transport code Nuclear heating in Cu and air in TLD's positions was calculated as well. The nuclear heating contribution from all simulated by MCNP6 code particles including protons, deuterons, alphas tritons and heavier ions produced by the neutron interactions were calculated. A trial of the direct comparison between experimental results and results of simulation was performed. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Improvements in the Tl dosimetry for Radiotherapy; Mejoras en la dosimetria Tl para Radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Bustos, S.; Velez, G.; Rubio, M. [CEPROCOR. Arenales 230 Juniors Cordoba 5000 (Argentina)

    1998-12-31

    The thermoluminescent dosimetry (TLD) in vivo has been demonstrated to be one of the most reliable for the control of radiotherapeutic treatments, but the delay in the response is the main disadvantage in its applicability. In this work are presented important improvements and it is demonstrated that maintaining the accuracy and reliability of the technique, it is possible to accelerate the response times at a few hours. To realize this work is utilized a lecturer Harshaw 4000, dosemeters LiF-TLD-100 chips (3.1 x 3.1 x 0.89 mm{sup 3}) and rods (1 x 1 x 6 mm{sup 3}). With the implementation of a glow curve analysis program developed in CIEMAT, its obtained a Tl peaks separation in such manner rapid and accurate, by that the thermal treatment of dosemeters may be reduced at one unique annealing pre-irradiation for 1 hr at 400 Centigrade. It is realized a periodical and individual calibration of the TLD and a study of the factors which influencing the ratio Tl signal-dose as linearity, correction by energy, directional response and pride of Tl signal. the results of this study are introducing in a calculation list specially designed and which allows to obtain absorbed dose by TLD starting of the dates (dosimetric peaks area) which appear of the glow curves analysis. The dose is obtained with an accuracy less than 5 %. The dosemeters already irradiated (in vivo) are analysed and informed in only four hours, allowing a greater control of the treatment and a correction of the possible errors for the next session, still in bi fractional treatments. The method implemented results thus accurate, rapid and reliable. (Author)

  3. Improvements in the Tl dosimetry for Radiotherapy

    International Nuclear Information System (INIS)

    Bustos, S.; Velez, G.; Rubio, M.

    1998-01-01

    The thermoluminescent dosimetry (TLD) in vivo has been demonstrated to be one of the most reliable for the control of radiotherapeutic treatments, but the delay in the response is the main disadvantage in its applicability. In this work are presented important improvements and it is demonstrated that maintaining the accuracy and reliability of the technique, it is possible to accelerate the response times at a few hours. To realize this work is utilized a lecturer Harshaw 4000, dosemeters LiF-TLD-100 chips (3.1 x 3.1 x 0.89 mm 3 ) and rods (1 x 1 x 6 mm 3 ). With the implementation of a glow curve analysis program developed in CIEMAT, its obtained a Tl peaks separation in such manner rapid and accurate, by that the thermal treatment of dosemeters may be reduced at one unique annealing pre-irradiation for 1 hr at 400 Centigrade. It is realized a periodical and individual calibration of the TLD and a study of the factors which influencing the ratio Tl signal-dose as linearity, correction by energy, directional response and pride of Tl signal. the results of this study are introducing in a calculation list specially designed and which allows to obtain absorbed dose by TLD starting of the dates (dosimetric peaks area) which appear of the glow curves analysis. The dose is obtained with an accuracy less than 5 %. The dosemeters already irradiated (in vivo) are analysed and informed in only four hours, allowing a greater control of the treatment and a correction of the possible errors for the next session, still in bi fractional treatments. The method implemented results thus accurate, rapid and reliable. (Author)

  4. Needle-type differential thermoluminescent dosemeter

    International Nuclear Information System (INIS)

    Kubu, M.

    1988-01-01

    The dosemeter serves to measure the depth distribution of absorbed dose in a phantom in mixed neutron and gamma radiation fields. It consists of a stratified cylindrical absorber in which alternate moderator and cadmium layers. Inside are two bores along the longitudinal axis for tubes filled with 6 LiF and 7 LiF powder thermoluminescent dosemeters. The device is easily portable and allows to carry out measurements with a high level of reproducibility. (J.B.). 4 figs

  5. A system for environmental monitoring

    International Nuclear Information System (INIS)

    Tawil, R.A.; Velbeck, K.J.; Rotunda, J.E.; Flory, C.; Moscovitch, M.

    1993-01-01

    The system described in this paper consists of a reader, multi-element dosemeters, and dose algorithm. The reader is a medium capacity non-contact gas heating unit interfaced to an application software package that evaluates and manages generated data. The dosemeter consists of elements that are 240 mg.cm -2 thick and which are symmetrically filtered. The two CaF 2 :Dy (TLD-200) elements are shielded by 80 mg.cm -2 ABS plastic, 0.25 mm tantalum and 0.05 mm lead. The two LiF:Mg,Ti (TLD-100) are shielded by the 80 mg.cm -2 ABS plastic only. The response of this system was characterised according to the criteria established in the ANSI Standard N545, Section 4, as modified by NRC Regulatory Guide 4.13. The procedures applied to study the energy response, fading, linearity, uniformity, minimum detectability, reproducibility, reponse dependence on angle of incidence are described, reviewed, and the results presented. The study also included self-irradiation, sensitivity to light and moisture, and performance in actual field conditions. The results demonstrate that this dosemeter satisfies all of the N545-1975 performance requirements. The dose calculation algorithm developed for this dosemeter is outlined and the accuracy of its performance in various pure and mixed fields has been determined. The results are presented and discussed. (author)

  6. Use of digital dosemeters for supporting staff radiation safety in paediatric interventional radiology suites

    International Nuclear Information System (INIS)

    McNeil, S. M.; Lai, P.; Connolly, B. L.; Gordon, C. L.

    2013-01-01

    Modern-day interventional radiology (IR) procedures impart a wide range of occupational radiation doses to team members. Unlike thermoluminescent badges, digital dosemeters provide real-time dose readings, making them ideal for identifying different components during IR procedures, which influence staff radiation safety. This study focused solely on paediatric IR (PIR) cases. Digital dosemeters measured the impact of imaging modality, shielding, patient and operator specific factors, on the radiation dose received during various simulated and real live PIR procedures. They recorded potential dose reductions of 10-to 100-fold to each staff member with appropriate use of shielding, choice of imaging method, staff position in the room and complex interplay of other factors. The digital dosemeters were well tolerated by staff. Results highlight some unique radiation safety challenges in PIR that arise from dose increases with magnification use and close proximity of staff to the X-ray beam. (authors)

  7. Use of digital dosemeters for supporting staff radiation safety in paediatric interventional radiology suites.

    Science.gov (United States)

    McNeil, Sarah M; Lai, Priscilla; Connolly, Bairbre L; Gordon, Christopher L

    2013-12-01

    Modern-day interventional radiology (IR) procedures impart a wide range of occupational radiation doses to team members. Unlike thermoluminescent badges, digital dosemeters provide real-time dose readings, making them ideal for identifying different components during IR procedures, which influence staff radiation safety. This study focused solely on paediatric IR (PIR) cases. Digital dosemeters measured the impact of imaging modality, shielding, patient and operator specific factors, on the radiation dose received during various simulated and real live PIR procedures. They recorded potential dose reductions of 10- to 100-fold to each staff member with appropriate use of shielding, choice of imaging method, staff position in the room and complex interplay of other factors. The digital dosemeters were well tolerated by staff. Results highlight some unique radiation safety challenges in PIR that arise from dose increases with magnification use and close proximity of staff to the X-ray beam.

  8. Colour dosemeters for high level radiation dosimetry

    DEFF Research Database (Denmark)

    Schönbacher, H.; Coninckx, F.; Miller, A.

    1990-01-01

    interpretation or a dose measurement with a simple instrument such as a portable reflecting densitometer in the range of 10(3) to 10(6) Gy. Two projects were investigated: (1) a thin plastic film with a self adhesive tape containing a radiochromic dye which induces a colour change when exposed to ionising...... of paint and film dosemeters were installed in the 450 GeV Super Proton Synchrotron (SPS) at CERN and irradiated during operation for more than two years. Within the useful range of the dosemeters, dose comparisons with other dosemeter types gave satisfactory results. Application in other fields...

  9. Poster - 24: Characterization of the energy dependence of high-sensitivity MCP-N TLD and Al2O3:C OSLD in-vivo dosimetry systems for 40–100 kVp energies

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, Yannick; Kuznetsova, Svetlana; Barajas, Eduardo Villarreal [Tom Baker Cancer Centre, Calgary AB, University of Calgary, Calgary AB, Tom Baker Cancer Center/University of Calgary, Calgary AB (Canada)

    2016-08-15

    Purpose: To characterize the energy dependence of high-sensitivity MCP-N TLD and Al{sub 2}O{sub 3}:C OSLD dosimetry systems at low (40–100 kVp) energies for in-vivo dosimetry. Methods: We assessed the variation of response with energy of two detectors in the 40–100 kVp energy range: high-sensitivity MCP-N TLDs (LiF:Mg,Cu,P) and OSLDs (Al{sub 2}O{sub 3}:C). The detectors were irradiated with an XRad 320ix biological irradiator under reference conditions. The delivered dose was 10 cGy for 7 beam qualities ranging from 40–100 kVp, 1.7–4.0 mm Al, and effective energies 26.9–37.9 keV. Both sets of detectors were also irradiated under reference conditions at 6 MV using a Varian Clinac 21Ex to assess the change in response from high-energy beams. Results: The MCP-N high-sensitivity TLDs were relatively insensitive to energies in the kV range, as their response varied by ±5%, i.e. well within the reproducibility limits of these detectors. However, the OSLDs exhibited a linearly-decreasing response with energy with a response 18.7% higher at 40 kVp than at 100 kVp for the same nominal dose. Compared to the 6 MV beams used in conventional radiotherapy, OSLDs responded 3.3–3.9 times higher depending on beam quality while the MCP-N TLD response was unchanged within experimental uncertainty. Conclusions: Unlike the more commonly used TLD-100, the high-sensitivity MCP-N TLDs exhibit little to no energy response. OSLDs are shown to be highly energy-dependent, both from MV to kV and within the kV range.

  10. The personnel dosimetry record keeping system at AEE Winfrith

    International Nuclear Information System (INIS)

    Gill, D.W.

    1979-09-01

    Since May 1978 the exposure of personnel to external radiation has been assessed by Thermoluminescent Dosimetry, (TLD). The dosemeter consists of a TLD card similar to that used by the National Radiological Protection Board, held in a plastic badge designed at AEE Winfrith, and used in conjunction with a D A Pitman Ltd Type 605 Automatic Reader. The report describes the dosemeter, the operation of the dosimetry service and the system for maintaining a computerised record keeping system. (author)

  11. Performance of Panasonic ZP-1460 Electronic Personal Dosemeter under Exposure Conditions Likely to be Found at Fukushima Daiichi Nuclear Power Plant

    Science.gov (United States)

    Tsujimura, Norio; Yoshida, Tadayoshi; Hoshi, Katsuya; Momose, Takumaro

    A study on the performance of the Panasonic ZP-1460 electronic personal dosemeter, the model used in the aftermath of the Fukushima Daiichi nuclear power plant accident in March 2011, was conducted under actual exposure situations likely encountered in the plant. The tests pertained to (1) the dose rate response over dose rates >100 mSv/h and (2) the angular response on an anthropomorphic phantom exposed to the rotational and isotropic irradiation geometries. The test results confirmed that the dosemeter provides Hp(10) as a reasonably close estimate of the effective dose for any exposure geometries. The dosemeter response data evaluated in this study can be utilized for converting dosemeter readings to the absorbed dose to any organs and tissues for epidemiologic purposes.

  12. The NRPB automated thermoluminescent dosemeter and dose record keeping system

    International Nuclear Information System (INIS)

    Dennis, J.A.; Marshall, T.O.; Shaw, K.B.

    1975-03-01

    This report describes the thermoluminescent personal radiation dosemeter and its associated automated processing equipment, which are being developed by the National Radiological Protection Board, together with the operation of a computerised dosemeter issue and record keeping system. The main justifications for introducing these systems are improvements in the organizational efficiency of the maintenance of individual dose records, a more flexible and accurate dosimetry system, and economics in operational costs. The dosemeter is based on a numbered aluminium plate containing two lithium fluoride in polytetrafluorethylene disks for the measurement of surface and body dose. This dosemeter is wrapped in thin plastic and labelled with the wearer's name and address. On return, the dosemeter is checked automatically for radioactive contamination; it is unwrapped and evaluated; the dose readings are included in the wearer's stored dose record; the dosemeter is annealed and is then available for re-issue to another wearer. Dose reports and warnings are automatically issued to the wearer or his employer. (author)

  13. Results of the EURATOM programme for comparison of individual dosemeters

    International Nuclear Information System (INIS)

    Julius, H.W.

    1976-01-01

    The results of the EURATOM dosemeter comparison-program for dosemeters used in the member states are given. Especially the results obtained in the Netherlands are examined and evaluated. The design and characteristics of the badge developed by the TNO-RD which are based on a thermoluminescent dosemeter are given

  14. EURADOS intercomparisons on whole body and extremity dosemeters (2008–2009) – Results and comparison of different dosemeter designs

    International Nuclear Information System (INIS)

    Stadtmann, H.; Grimbergen, T.W.M.; Figel, M.; Romero, A.M.; Mcwhan, A.F.

    2011-01-01

    The EURADOS (European Radiation Dosimetry Group) working group (WG2) on Harmonisation of Individual Monitoring in Europe has shown that intercomparisons are fundamental for harmonisation of individual monitoring. As a result of these considerations, EURADOS started to prepare a series of continuous intercomparisons for individual monitoring services (IMS) in Europe. EURADOS has now successfully executed two intercomparison exercises, one for whole body dosemeters (2008) and one for extremity dosemeters (2009). Both exercises were performed without external funding, all costs being covered by the participants’ fees. More than 120 (!) different – mainly passive – dosimetry systems were tested from all over Europe until now and the results were analysed and compared. Although scientific studies were not the primary objective of these exercises specific additional information about the tested systems supplied by the participants for statistical analysis allows a detailed analysis of these results with respect to different parameters like dosemeter type, detector material, filter thickness or others design parameters. The influence of such parameters on the response values of the dosemeters is analysed and discussed in this paper. Both energy response as well as directional response for beta and photon radiation are considered. The influence of different design parameters e.g. detector material, is analysed by comparing the frequency distribution of the response values for different dosemeter groups. Pronounced differences for different detector materials (LiF:Mg,Ti, LiF:Mg,Cu,P and Li 2 B 4 O 7 /CaSO 4 ) were found. The paper gives a comprehensive overview on the performance of various European dosimetry services and the influence of the dosemeter design on the resulting response values.

  15. Individual dosemeter with ionization chamber for intervention

    International Nuclear Information System (INIS)

    Prigent, M.

    1982-01-01

    The altogether intervention ratemeter-dosemeter is a device for work condition control and for dosimetry of intervention gang in hostile medium. A portable irradiation marker with ionization chamber either carried by staff, either put at the work post, delivers an information function of the surrounding irradiation field in which moves the intervention staff. The information is processed so as the absorbed dose rate and the absorbed dose are given simultaneously. The connection between the marker and the process device is made by a cable (up to 100m) or by radio link [fr

  16. Glass as a gamma ray dosemeter

    International Nuclear Information System (INIS)

    Sutrisno Puspodikoro.

    1978-01-01

    The advantages of glass as a γ-rays dosemeter are studied. Experiments have shown that ordinary microscope object glass can be used as a dosemeter, which dose range for linear response extends from about 10 4 -10 6 rads. Heat treatment of the irradiated samples accelerates the initial fading of coloration and stabilizes the residual optical density. On the other side cooling of them retards the initial fading. (author)

  17. Personnel dose equivalent monitoring at SLAC using lithium-fluoride TLD's [thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Jenkins, T.M.; Busick, D.D.

    1987-03-01

    TLD's replaced film badges in the early 1970's for all dose equivalent monitoring, both neutron and photon, and for all locations at SLAC. The photon TLD's, composed of Li-7 loaded teflon discs, are calibrated using conventional gamma-ray sources; i.e., Co-60, Cs-137, etc. For these TLD's a nominal value of 1 nC/mrem is used, and is independent of source energy for 100 keV to 3 MeV. Since measured dose equivalents at SLAC are only a small fraction of the allowable levels, it was not deemed necessary to develop neutron dosimeters which would measure dose equivalent accurately for all possible neutron spectra. Today, wallet TLD's, composed of pairs of Li-7 and Li-6 discs, are used, with the Li-6 measuring only thermal neutrons; i.e., they aren't moderated in any way to make them sensitive to neutrons with energies greater than thermal. The assumption is made that there is a correlation between thermal neutron fluences and fast neutron fluences around the research area where almost all neutron doses (exclusive of sealed sources) are received. The calibration factor for these Li-6 TLD's is 1 nC/mrem of fast neutrons. The method of determining the validity of this calibration is the subject of this note. 4 refs., 9 figs., 1 tab

  18. TL detectors for gamma ray dose measurements in criticality accidents

    International Nuclear Information System (INIS)

    Miljanic, S.; Zorko, B.; Gregori, B.; Knezevic, Z.

    2007-01-01

    Determination of gamma ray dose in mixed neutron + gamma ray fields is still a demanding task. Dosemeters used for gamma ray dosimetry are usually in some extent sensitive to neutrons and their response variations depend on neutron energy i.e., on neutron spectra. Besides, it is necessary to take into account the energy dependence of dosemeter responses to gamma rays. In this work, several types of thermoluminescent detectors (TLD) placed in different holders used for gamma ray dose determination in the mixed fields were examined. Dosemeters were from three different institutions: Ruder Boskovic Inst. (RBI), Croatia, Jozef Stefan Inst. (JSI), Slovenia and Autoridad Regulatoria Nuclear (ARN), Argentina. All dosemeters were irradiated during the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002. Three accidental scenarios were reproduced and in each irradiation the dosemeters were exposed placed on the front of phantom and 'free in air'. Following types of TLDs were used: 7 LiF (TLD-700), CaF 2 :Mn and Al2 O3 :Mg,Y - all from RBI; CaF 2 :Mn from JSI and 7 LiF (TLD-700) from ARN. Reported doses were compared with the reference values as well as with the values obtained from the results of all participants. The results show satisfactory agreement with other dosimetry systems used in the Intercomparison. The influence of different types of holders and applied corrections of dosemeters' readings are discussed. (authors)

  19. TL detectors for gamma ray dose measurements in criticality accidents.

    Science.gov (United States)

    Miljanić, Saveta; Zorko, Benjamin; Gregori, Beatriz; Knezević, Zeljka

    2007-01-01

    Determination of gamma ray dose in mixed neutron+gamma ray fields is still a demanding task. Dosemeters used for gamma ray dosimetry are usually in some extent sensitive to neutrons and their response variations depend on neutron energy i.e., on neutron spectra. Besides, it is necessary to take into account the energy dependence of dosemeter responses to gamma rays. In this work, several types of thermoluminescent detectors (TLD) placed in different holders used for gamma ray dose determination in the mixed fields were examined. Dosemeters were from three different institutions: Ruder Bosković Institute (RBI), Croatia, JoZef Stefan Institute (JSI), Slovenia and Autoridad Regulatoria Nuclear (ARN), Argentina. All dosemeters were irradiated during the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002. Three accidental scenarios were reproduced and in each irradiation the dosemeters were exposed placed on the front of phantom and 'free in air'. Following types of TLDs were used: 7LiF (TLD-700), CaF2:Mn and Al2O3:Mg,Y-all from RBI; CaF2:Mn from JSI and 7LiF (TLD-700) from ARN. Reported doses were compared with the reference values as well as with the values obtained from the results of all participants. The results show satisfactory agreement with other dosimetry systems used in the Intercomparison. The influence of different types of holders and applied corrections of dosemeters' readings are discussed.

  20. A personal radon dosemeter

    International Nuclear Information System (INIS)

    Oberstedt, S.; Vanmarcke, H.

    1994-03-01

    In the last decade the radon issue has become one of the major problems of radiation protection. Animal studies as well as epidemiological studies showed an increased lung cancer risk. A new personal radon-dosemeter on the basis of a CR-39 (poly-allyl diglycol carbonate) track-etch detector has been developed. The read-out of the detectors is based on the image- processing technique. The actual efficiency of the new dosemeter, obtained with a semi-automatic personal-computer based image-analysis system, is 1.43 +/- 0.15 tracks/cm 2 /(kBq/m 3 h), which is about three times that of the widely used Karlsruhe-type detector based on polycarbonate detectors

  1. Using operational equipment to read accident dosemeters.

    Science.gov (United States)

    Devine, R T; Vigil, M M; Martinez, W A

    2004-01-01

    Analysis of accident dosemeters usually involves the use of laboratory-based counting equipment. Gamma spectrometers are used for indium, copper and gold, and alpha-beta detectors for sulphur. This equipment is usually not easily transported due to the shielding required and the weight and delicacy of the counters. For intercomparison studies that require reading the dosemeters on site, a transportable system is required unless the site operating the study can count samples for all the participants. In the case of an actual accident these systems would have a difficulty in counting a large number of accident dosemeters. In an accident, personnel are usually subdivided according to their level of exposure. Those exposed to higher doses are treated immediately. An alternate system should be made available to handle the dosemeters worn by those personnel are likely to receive lower doses. Improvements in portable operational equipment for gamma and beta monitoring allow their use as spectrometers. Such a system was used for the SILENE intercomparison conducted at IRSN Valduc on 12 June and 19, 2002, and the preliminary results compared well with the other participants.

  2. Calibration of clinical dosemeters in the IAEA water phantom

    International Nuclear Information System (INIS)

    Caldas, L.V.E.; Albuquerque, M.P.P.

    1994-01-01

    The procedures recommended by the IAEA Code of Practice were applied at the Calibration Laboratory of Sao Paulo in order to provide in the future the clinical dosemeters users with absorbed dose to water calibration factors for Cobalt 60 radiation beams. In this work the clinical dosemeters were calibrated free in air and in water, and the results were compared, using conversion factors. The several tested clinical dosemeters of different manufacturers and models belong to the laboratory and to hospitals. For the measurements in water the IAEA cubic water phantom was used. The dosemeters were all calibrated free in air in terms of air kerma, and the calibration factors in terms of absorbed dose to water were obtained through conversion factors. the same dosemeters were also calibrated into the water phantom. Good agreement was found between the two methods, the differences were always less than 0.5%. The data obtained during this work show that when the dosemeters are used only in Cobalt 60 radiation and the users apply in the hospital routine work the IAEA Code of Practice, the calibration can be performed directly in the water phantom. This procedure provides the useful calibration factors in terms of absorbed dose to water

  3. Effective energies and exposure determinations of two different energy X-ray beams incident on a personnel monitor

    International Nuclear Information System (INIS)

    Okuno, E.; Cruz, M.T. da

    1984-01-01

    The effective energy of one X or gamma ray beam can be determined by means of two thermoluminescent (TL) dosemeters mounted between suitable filters. However, it has been observed that personnel monitors exposed to two different energy ionizing radiations provide different effective energies depeding on the type of TL phosphor used. This fact could be a powerful tool for identifying exposures to radiation with quite different effective energies which are very common in practice. Two types of TL dosemeters were used : pellets of cold pressed natural fluoride and NaCl developed in our own laboratory, and LiF, TLD-100 from Harshaw Chemical Co.. Experimental results obtained with these combined dosemeters after irradiation with different sets of exposures and energy values of ionizing radiations are also presented. (Author) [pt

  4. Elaboration of pellets of LiF: Mg, Cu, P and its dosimetric properties

    International Nuclear Information System (INIS)

    Gutierrez C, A.; Gonzalez M, P.R.; Azorin N, J.

    1991-03-01

    The LiF: Mg, Cu, P is at the moment in the entire world one of the TL materials of more interest, by its equivalence with the tissue, as well as for its high sensitivity, which is 25 to 35 times greater than of the TLD-100 of Harshaw (USA). In our laboratory dosemeters of this material have been developed in form of sinterized pellets. The importance of these new dosemeters in pellet form is due to that in this form its manipulation is facilitated. Due to its high sensitivity, these dosemeters result to be those but appropriate to measure the ionizing radiations, in intervals of extremely low dose. In this report the method of elaboration of the pellets, as well as its main dosimetric characteristics are presented. (Author)

  5. Elaboration of pellets of LiF: Mg, Cu, P and its dosimetric properties; Elaboracion de pastillas de LiF: Mg, Cu, P y sus propiedades dosimetricas

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez C, A.; Gonzalez M, P.R.; Azorin N, J

    1991-03-15

    The LiF: Mg, Cu, P is at the moment in the entire world one of the TL materials of more interest, by its equivalence with the tissue, as well as for its high sensitivity, which is 25 to 35 times greater than of the TLD-100 of Harshaw (USA). In our laboratory dosemeters of this material have been developed in form of sinterized pellets. The importance of these new dosemeters in pellet form is due to that in this form its manipulation is facilitated. Due to its high sensitivity, these dosemeters result to be those but appropriate to measure the ionizing radiations, in intervals of extremely low dose. In this report the method of elaboration of the pellets, as well as its main dosimetric characteristics are presented. (Author)

  6. Electron scattering effects on absorbed dose measurements with LiF-dosemeters

    International Nuclear Information System (INIS)

    Bertilsson, G.

    1975-10-01

    The investigation deals with absorbed dose measurements with solid wall-less dosemeters. Electron scattering complicates both measurement of absorbed dose and its theoretical interpretation. The introduction of the dosemeter in a medium causes perturbations of the radiation field. This perturbation and its effect on the distribution of the absorbed dose inside the dosemeter is studied. Plane-parallel LiF-teflon dosemeters (0.005 - 0.1 g.cm -2 ) are irradiated by a photon beam ( 137 Cs) in different media. The investigation shows that corrections must be made for perturbations caused by electron scattering phenomena. Correction factors are given for use in accurate absorbed dose determinations with thermoluminescent dosemeters. (Auth.)

  7. Occupational radiation exposure in Slovakia

    International Nuclear Information System (INIS)

    Boehm, K.; Cabanekova, H.

    2014-01-01

    Recently are 2 nuclear power plants in operation in the Slovak republic. Apart from nuclear facilities there are 450 licensed undertakings with monitored workers. The majority of the licensed undertakings are active in health care. In Slovak republic are five dosimetry services performing assessments on personal doses due to external exposure and two dosimetry services are approved to carry out monitoring of internal exposure. Dosemeters used for the monitoring of external individual exposure include: personal whole-body film dosemeters, thermoluminescence dosemeters (TLD) or optically stimulated luminescence dosimeters (OSL) for measurements of beta and gamma radiation; TLD for measurements of neutron radiation and TLD for extremities. The measured operational dose quantities are Hp(10), Hp(3) and Hp(0.07). Approved dosimetry service reports the measured dose data to the employers and to the Central register of occupational doses (CROD). Annually are monitored about 12500 - 16200 active workers. Average effective doses per one monitored worker are presented. (author)

  8. A new, passive dosemeter for gamma, beta and neutron radiations

    Energy Technology Data Exchange (ETDEWEB)

    Jones, L A; Stokes, R P, E-mail: rpstokes@dstl.gov.uk [Defence Science and Technology Laboratory, Environmental Sciences Department, Alverstoke, Gosport, Hants, PO12 2DL (United Kingdom)

    2011-03-01

    The Defence Science and Technology Laboratory (Dstl) provides personal radiation dosimetry to the UK Ministry of Defence. Dstl has recently developed a dosemeter that is based on a combination of thermoluminescent and etched-track detectors. The Dstl Combined Dosemeter is capable of assessing doses due to photons, beta particles and neutrons. This paper presents the laboratory type testing results for the Combined Dosemeter, and also describes the procedure for calibrating the dosemeter for use in workplace neutron fields. The Combined Dosemeter meets the type test requirements that are relevant to its intended applications, and gives neutron doses that are within 50% of the true dose in the workplaces in which it is used, even when the wearer has the potential to be exposed to a variety of neutron spectra (e.g. on board nuclear-powered submarines).

  9. A new, passive dosemeter for gamma, beta and neutron radiations

    International Nuclear Information System (INIS)

    Jones, L A; Stokes, R P

    2011-01-01

    The Defence Science and Technology Laboratory (Dstl) provides personal radiation dosimetry to the UK Ministry of Defence. Dstl has recently developed a dosemeter that is based on a combination of thermoluminescent and etched-track detectors. The Dstl Combined Dosemeter is capable of assessing doses due to photons, beta particles and neutrons. This paper presents the laboratory type testing results for the Combined Dosemeter, and also describes the procedure for calibrating the dosemeter for use in workplace neutron fields. The Combined Dosemeter meets the type test requirements that are relevant to its intended applications, and gives neutron doses that are within 50% of the true dose in the workplaces in which it is used, even when the wearer has the potential to be exposed to a variety of neutron spectra (e.g. on board nuclear-powered submarines).

  10. Dosimetric quality control in radiotherapy using TLD methodology

    International Nuclear Information System (INIS)

    Saravi, M.C.; Kessler, C.; Alvarez, P.E.; Feld, D.B.

    2002-01-01

    , 10 MV and 15 MV accelerating potentials were within the uncertainty limits of measurements. Each centre participates in the high energy photon beam audits in reference conditions at least once a year. After evaluating the TLD capsules the dose deviation is calculated: Dev=(D A - D TLD ).100/D TLD . When the dose deviation is greater than 5%, the causes of discrepancy are investigated and follow-up actions are carried out by the EAG

  11. Improvement of the calibration technique of clinical dosemeters

    International Nuclear Information System (INIS)

    Ehlin Caldas, L.V.

    1988-08-01

    Clinical dosemeters constituted of ionization chambers connected to electrometers are usually calibrated as whole systems in appropriate radiation fields against secondary standard dosemeters in calibration laboratories. This work reports on a technique of component calibration procedures separately for chambers and electrometers applied in the calibration laboratory of IPEN-CNEN, Brazil. For electrometer calibration, redundancy was established by using a standard capacitor of 1000pF (General Radio, USA) and a standard current source based on air ionization with Sr 90 (PTW, Germany). The results from both methods applied to several electrometers of clinical dosemeters agreed within 0.4%. The calibration factors for the respective chambers were determined by intercomparing their response to the response of a certified calibrated chamber in a Co 60 calibration beam using a Keithley electrometer type 617. Overall calibration factors compared with the product of the respective component calibration factors for the tested dosemeters showed an agreement better than 0.7%. This deviation has to be considered with regard to an uncertainty of 2.5% in routine calibration of clinical dosemeters. Calibration by components permits to calibrate ionization chambers one at a time for those hospitals who have several ionization chambers but only one electrometer (small hospitals, hospitals in developing countries). 6 refs, 2 figs, 2 tabs

  12. Specification for personal photographic dosemeters

    International Nuclear Information System (INIS)

    1981-01-01

    The 1981 British/International Standard Specification, prepared under the direction of the Nuclear Engineering Standards Committee and TC85 of the International Organization for Standardization, is described for personal photographic dosemeters. The Standard specifies classification, characteristics and test procedures to determine absorbed doses due to X or gamma radiations (energy less than 3 MeV) and absorbed doses due to beta radiation (max. energy 0.6 to 3 MeV), whether or not accompanied by X, gamma or bremsstrahlung photon radiation. The Standard is particularly applicable to dosemeters intended to be carried on the chest or wrist. (U.K.)

  13. RFID based TLD monitoring system - a prospective development

    International Nuclear Information System (INIS)

    Jeevanram, S.S.; Pawar, S.T.; Mahule, K.N.; Rath, D.P.

    2008-01-01

    Thermo Luminescence Dosimetry (TLD) is an established method of monitoring the radiation dose received by workers in radiation environments. In Radiometallurgy Laboratory, BARC, the TLD movement inside a nuclear facility is completely carried out by a radiation worker. However, there is a chance that the TLDs may get lost in laboratories or some places without the knowledge of the concerned TLD user or health physicist. It may later lead to a false effective dose. Effort is being done to initiate a RFID based TLD monitoring system so that the use of TLD can be acknowledged through a self operating software which can prevent misuse of the detector. A novel method of improving the administrative control through Radio Frequency Identification (RFID) based monitoring to avoid such inadvertent misplacement of TLD, is in progress. This paper discusses the method and techniques through which administrative control can be exercised to reduce the number of such in explainable exposures. (author)

  14. Calibration of Far West Technology (FWT-60) radiachromic dye dosemeters

    International Nuclear Information System (INIS)

    Mincher, B.J.; Zaidi, M.K.

    1992-01-01

    Radiachromic dye dosimetry was used to measure kilogray doses absorbed by various liquid samples during gamma-ray exposure in a spent nuclear fuel pool. The source of nuclear fuel was the Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory (INEL). Calibrations were performed using a 60 Co source and were run on bare dosemeters, as well as on dosemeters which mocked to simulate the samples. These dosemeters were prepared as a dye-impregnated nylon film and are commercially available. When exposed to gamma-ray doses of 0.5 to 200 kGy, a color change occurs which has an optical density proportional to absorbed dose. The difference in the calibration curves demonstrated the importance of irradiation of dosemeters under conditions as close to the actual samples as possible. Since these dosemeters could not be immersed directly in the organic solutions of interest, they were sandwiched between layers of lucite and stainless steel. This simulated the conditions inside an irradiated sample and provides a practical method of measuring absorbed doses. The reproducibility of measurements using the radiachromic dye dosemeters is also shown. 10 refs

  15. TL detectors for gamma-ray dose measurements in critically accidents

    International Nuclear Information System (INIS)

    Miljanic, S.; Knezevic, Z.; Zorko, B.; Gregori, B.

    2005-01-01

    Full text: Determination of gamma-ray dose in mixed neutron + gamma-ray fields is still a challenging task. Dosemeters used for gamma-ray dosimetry are usually in some extent sensitive to neutrons and their response variations depend on neutron energy i.e. on neutron spectra. Besides, it is necessary to take into account the energy dependence of dosimeter responses to gamma-rays. To reduce all these influences, design of dosemeter holders is of special importance. In this work, several types of thermoluminescent detectors (TLD) placed in different holders used for gamma-ray dose determination in mixed fields were examined. Dosemeters were from three different institutions: Ruder Boscovic Institute (RBI), Croatia, Jozef Stefan Institute (JSI), Slovenia and Autoridad Regulatoria Nuclear (ARN), Argentina. All dosemeters were irradiated during the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002. At that exercise three accidental scenarios were reproduced: bare reactor, free evolution; lead shielded reactor, steady state; and lead shielded reactor, free evolution. In each irradiation dosemeters were exposed placed on the front of phantom and 'free-in-air'. Also, dosemeters were irradiated in a pure gamma ray field of 60 Co source. Following types of TLDs were used: 7 LiF (TLD-700), CaF 2 :Mn and AI 2 O 3 :Mg,Y - all from RBI; CaF 2 :Mn from JSI and 7 LiF (TLD-700) from ARN. Reported doses were compared with the reference values as well as with the mean participants' values. The results show satisfactory agreement with other dosimetry systems used in the Intercomparison. The influence of different types of holders and applied corrections of dosemeters' readings are discussed. (author)

  16. Environmental radiation measurements using lithium fluoride thermoluminescence dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Driscoll, C.M.H.; Green, B.M.R.; McKinlay, A.F.; Richards, D.J. (National Radiological Protection Board, Harwell (UK))

    1984-01-01

    The National Radiological Protection Board is involved in a large scale environmental survey of radiation levels in homes throughout the United Kingdom. Passive radon and gamma ray dosemeters are posted to a representative sample of households. Lithium fluoride thermoluminescence dosemeters are used to assess natural gamma radiation and are left in the measurement location for a period of six months before being returned to the Board for processing. As a preliminary to the national survey, the Board has been engaged on several limited surveys in regions of igneous and sedimentary geology. Experience gained in these limited surveys and from standardisation studies using environmental dosemeters are reported.

  17. Personal neutron dosimetry at a research reactor facility

    International Nuclear Information System (INIS)

    Kamenopoulou, V.; Carinou, E.; Stamatelatos, I.E.

    2001-01-01

    Individual neutron monitoring presents several difficulties due to the differences in energy response of the dosemeters. In the present study, an individual dosemeter (TLD) calibration approach is attempted for the personnel of a research reactor facility. The neutron energy response function of the dosemeter was derived using the MCNP code. The results were verified by measurements to three different neutron spectra and were found to be in good agreement. Three different calibration curves were defined for thermal, intermediate and fast neutrons. At the different working positions around the reactor, neutron spectra were defined using the Monte Carlo technique and ambient dose rate measurements were performed. An estimation of the neutrons energy is provided by the ratio of the different TLD pellets of each dosemeter in combination with the information concerning the worker's position; then the dose equivalent is deduced according to the appropriate calibration curve. (author)

  18. An automated thermoluminescence dosimetry (TLD) system

    International Nuclear Information System (INIS)

    Kicken, P.J.H.; Huyskens, C.J.

    1979-01-01

    In the Health Physics Division of the Eindhoven University of Technology work is going on in developing an automated TLD-system. Process automization, statistical computation, dose calculation as well as dose recording are carried out, using a microcomputer and floppy disk unit. The main features of this TLD-system are its low costs, flexibility, easy to operate, and the feasibility for use in routine dosimetry as well as in complex TLD research. Because of its modular set-up several components of the system are multifunctional in other operations. The system seems suited for medium sized Health Physics groups. (Auth.)

  19. Determination of isodose curves in Radiotherapy using an Alanine/ESR dosemeter; Determinacion de curvas de isodosis en Radioterapia usando un dosimetro de Alanina/ESR

    Energy Technology Data Exchange (ETDEWEB)

    Chen, F.; Baffa, O.; Graeff, C.F.O. [Departamento de Fisica e Matematica. Universidade de Sao Paulo FFCLRP. 14040-901 Ribeirao Preto-SP (Brazil)

    1998-12-31

    It was studied the possible use of an Alanine/ESR dosemeter in the isodose curves mapping in normal treatments of Radiotherapy. It was manufactured a lot of 150 dosemeters with base in a mixture of D-L Alanine dust (80 %) and paraffin (20 %). Each dosemeter has 4.7 mm diameter and 12 mm length. A group of 100 dosemeters of the lot were arranged inside 50 holes of the slice 25 of the phantom Rando Man. The phantom irradiation was realized in two opposed projections (AP and PA) in Co-60 equipment. A group of 15 dosemeters was take of the same lot for obtaining the calibration curve in a 1-20 Gy range. After irradiation the signal of each dosemeter was measured in an ESR spectrometer operating in the X-band ({approx} 9.5 GHz) and the wideness of Alanine ESR spectra central line was correlated with the radiation dose. The wideness dose calibration curve resulted linear with a correlation coefficient 0.9996. The isodose curves obtained show a profile enough similar at comparing with the theoretical curves. (Author)

  20. The evaluation of multi-element personal dosemeters using the linear programming method

    International Nuclear Information System (INIS)

    Kragh, P.; Ambrosi, P.; Boehm, J.; Hilgers, G.

    1996-01-01

    Multi-element dosemeters are frequently used in individual monitoring. Each element can be regarded as an individual dosemeter with its own individual dose measurement value. In general, the individual dose values of one dosemeter vary according to the exposure conditions, i. e. the energy and angle of incidence of the radiation. The (final) dose measurement value of the personal dosemeter is calculated from the individual dose values by means of an evaluation algorithm. The best possible dose value, i.e. that of the smallest systematic (type B) uncertainty if the exposure conditions are changed in the dosemeter's rated range of use, is obtained by the method of linear programming. (author)

  1. Individual monitoring with official electronic dosemeters in Germany - concepts and reality

    International Nuclear Information System (INIS)

    Martini, E.; Wahl, W.; Huebner, S.; Freynhagen, D.; Staemmler, M.

    2005-01-01

    Full text: Active (electronic) personal dosemeters (APD) are radiometers, which are equipped as active or passive dosimeters. They can directly indicate a dose rate and/or the dose integrated during a certain period (direct-indicating, active electronic personal dosemeters mentioned) or only over a separate reader (direct-selectable, passive electronic personal dosemeters mentioned). A concept is presented for the use of passive or active electronic personal dosemeters in Germany as official dosemeters, e.g. in hospitals. The concept features a net-based approach for secure data communication between readers for passive and active electronic personal dosemeters und the official personal dosimetry monitoring service(s), taking the German policies (StrISchV und RoeV in hospitals) into account. The net-based solution includes a processor controlled interface via TCP/IP connected to the dosimetry reader(s), und reader interfaces, an official interim data bank and all the necessary equipment such as PC, Raid-configuration, USV support, network connection and further details. Investigations have been started to achieve highest-level data manipulation security, data completeness und data correctness. (author)

  2. Personnel monitoring of radiations with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Miano, S.C.

    1987-01-01

    The basics of personnel dosimetry technics, used by the Radiologic Protetion and Assessorie Service (SAPRA) are presented, consisting on use of thermoluminescent and CaSO 4 :Dy monitors in aggregated pellets by Teflon. The characteristics of this dosemeters, relating to the sensitivity, energetic dependence, spike temperature, characteristic emission curve, decay and light effect are shown. The thermoluminescent dosemeter measure system and the personnel monitoring system are also described. (C.G.C.) [pt

  3. Understanding differences in dose-equivalents reported by passive and electronic personal dosemeters

    International Nuclear Information System (INIS)

    Perks, Christopher A.; Burgess, Peter; Smith, David; Salasky, Mark; Yahnke, Cliff

    2008-01-01

    Full text: In a number of challenging environments, clients occasionally double badge with electronic personal dosemeters (EPDs) to ensure day-to-day management of their employees personal dose-equivalent while using passive (in our case Luxel or InLight) dosemeters for monthly monitoring for approved results for dose record keeping. In some cases there have been significant differences in the cumulative doses recorded by the EPDs and the passive dosemeters. In these circumstances the passive dosemeters usually report a higher dose than the EPD by up to a factor of two, though more commonly 1.3. In this paper we describe the differences seen between EPD and passive dosemeters (in a number of countries). We then examine the possible causes for such discrepancies by comparison with published response function data available for the EPDs and Landauer dosemeters. We have undertaken a number of experiments comparing directly a number of EPDs and passive dosemeter response to a variety of energy and complex angular geometries where the two types of dosimeter have been exposed at the same time. Recommendations will be made on the appropriate use of double badging in difficult environments and interpretation of the results. (author)

  4. Using signal ''KVANT-1'' direct-reading dosemeter for the purposes of personnel monitoring

    International Nuclear Information System (INIS)

    Glinskij, G.A.; Karasev, V.S.; Mukhin, I.E.; Chumak, V.K.

    1977-01-01

    Presented is the description of ''KVANT-1'' dosemeter for monitoring personnel doses of gamma and X radiation. The dosemeter permits to judge on the radiation intensity, to control directly the dose being accumulated, to store the reading of the dose accumulated for a necessary period of time, to obtain sound signal in case of reaching the limit of a pre-set dose. Presented are a general view, block diagram, and the discription of the dosemeter desing and operation. Advantages of the ''KVANT-1'' dosemeter are shown as compared with the conventional personnel monitoring IFK-2,3 and KID-2 dosemeters [ru

  5. Calibration of farmer dosemeters

    International Nuclear Information System (INIS)

    Ahmad, S.S.; Anwar, K.; Arshed, W.; Mubarak, M.A.; Orfi, S.D.

    1984-08-01

    The Farmer Dosemeters of Atomic Energy Medical Centre (AEMC) Jamshoro were calibrated in the Secondary Standard Dosimetry Laboratory (SSDL) at PINSTECH, using the NPL Secondary Standard Therapy level X-ray exposure meter. The results are presented in this report. (authors)

  6. Passive dosemeter

    International Nuclear Information System (INIS)

    Hassib, G.; Piesch, E.

    1981-01-01

    The dosemeter will be used for the detection of radon and thoron as well as their daughter products. It consists of two chambers with nuclear trace or alpha detectors. Both chambers are connected with one another at their front sides with a filter arranged in between. One of the chambers has got lateral openings, it is used as a diffusion chamber. In the other chamber exclusively radon and thoron are detected. (DG) [de

  7. Development of an algorithm for X-ray exposures using the Panasonic UD-802A thermoluminescent dosemeter

    International Nuclear Information System (INIS)

    McKittrick, Leo; Currivan, Lorraine; Pollard, David; Nicholls, Colyn; Romero, A.M.; Palethorpe, Jeffrey

    2008-01-01

    Full text: As part of its continuous quality improvement the Dosimetry Service of the Radiological Protection Institute of Ireland (RPII) in conjunction with Panasonic Industrial Europe (UK) has investigated further the use of the standard Panasonic algorithm for X-ray exposures using the Panasonic UD-802A TL dosemeter. Originally developed to satisfy the obsolete standard ANSI 13.11-1983, the standard Panasonic dose algorithm has undergone several revisions such as HPS N13.11-2001. This paper presents a dose algorithm that can be used to correct the dose response at low energies such as X-ray radiation using a four element TL dosemeter due to the behaviour of two different independent phosphors. A series of irradiations with a range of energies using N-20 up to Co-60 were carried out with our particular interest being in responses to X-ray irradiations. Irradiations were performed at: RRPPS, University Hospital Birmingham NHS Foundation Trust, U.K.; HPA, U.K. and CIEMAT, Madrid, Spain. Different irradiation conditions were employed which included: X-ray from narrow and wide spectra as described by ISO 4037-1 (1996), and ISO water slab phantom and PMMA slab phantom respectively. Using the UD-802A TLD and UD-854AT hanger combination, the response data from the series of irradiations was utilised to validate and if necessary, modify the photon/beta branches of the algorithm to: 1. Best estimate Hp(10) and Hp(0.07); 2. Provide information on irradiation energies; 3. Verification by performance tests. This work further advances the algorithm developed at CIEMAT whereby a best-fit, polynomial trend is used with the dose response variations between the independent phosphors. (author)

  8. Differences in TLD 600 and TLD 700 glow curves derived from distict mixed gamma/neutron field irradiations

    International Nuclear Information System (INIS)

    Cavalieri, Tassio A.; Castro, Vinicius A.; Siqueira, Paulo T.D.

    2013-01-01

    In Neutron Capture Therapy, a thermal neutron beam shall impinge on a specific nuclide, such as 10 B, to promote a nuclear reaction which releases the useful therapeutic energy. A nuclear reactor is usually used as the neutron source, and therefore field contaminants such as gamma and high energy neutrons are also present in the field. However, mixed field dosimetry still stands as a challenge in some cases, due to the difficulty to experimentally discriminate the dose from each field component. For the mixed field dosimetry, the International Commission on Radiation end Units (ICRU) recommends the use of detector pairs with different responses for each beam component. The TLD 600/700 pair meets this need, because these LiF detectors have different Li isotopes concentration, with distinct thermal neutron responses because 6 Li presents a much higher neutron capture cross section than does 7 Li for low energy neutrons. TLD 600 is 6 Li enriched while TLD 700 is 7 Li enriched. However, depending on the neutron spectrum presented in the mixed field, TLD 700 response to thermal neutrons cannot be disregarded. This work aims to study the difference in TLD 600 and TLD 700 glow curves when these TLDs are submitted to mixed fields of different energy spectra and components balance. The TLDs were irradiated in a pure gamma source, and in mixed fields from an AmBe sealed source and from the IPEN/MB-01 reactor. These TLDs were read and had their two main dosimetric regions analyzed to observe the differences in the glow curves of these TLDs in each irradiation. Field components discrimination was achieved through Monte Carlo simulations run with MCNP radiation transport code. (author)

  9. Prediction analysis of dose equivalent responses of neutron dosemeters used at a MOX fuel facility

    International Nuclear Information System (INIS)

    Tsujimura, N.; Yoshida, T.; Takada, C.

    2011-01-01

    To predict how accurately neutron dosemeters can measure the neutron dose equivalent (rate) in MOX fuel fabrication facility work environments, the dose equivalent responses of neutron dosemeters were calculated by the spectral folding method. The dosemeters selected included two types of personal dosemeter, namely a thermoluminescent albedo neutron dosemeter and an electronic neutron dosemeter, three moderator-based neutron survey meters, and one special instrument called an H p (10) monitor. The calculations revealed the energy dependences of the responses expected within the entire range of neutron spectral variations observed in neutron fields at workplaces. (authors)

  10. Comparative study on skin dose measurement using MOSFET and TLD for pediatric patients with acute lymphatic leukemia.

    Science.gov (United States)

    Al-Mohammed, Huda I; Mahyoub, Fareed H; Moftah, Belal A

    2010-07-01

    The object of this study was to compare the difference of skin dose measured in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using metal oxide semiconductor field-effect transistors (mobile MOSFET dose verification system (TN-RD-70-W) and thermoluminescent dosimeters (TLD-100 chips, Harshaw/ Bicron, OH, USA). Because TLD has been the most-commonly used technique in the skin dose measurement of TBI, the aim of the present study is to prove the benefit of using the mobile MOSFET (metal oxide semiconductor field effect transistor) dosimeter, for entrance dose measurements during the total body irradiation (TBI) over thermoluminescent dosimeters (TLD). The measurements involved 10 pediatric patients ages between 3 and 14 years. Thermoluminescent dosimeters and MOSFET dosimetry were performed at 9 different anatomic sites on each patient. The present results show there is a variation between skin dose measured with MOSFET and TLD in all patients, and for every anatomic site selected, there is no significant difference in the dose delivered using MOSFET as compared to the prescribed dose. However, there is a significant difference for every anatomic site using TLD compared with either the prescribed dose or MOSFET. The results indicate that the dosimeter measurements using the MOSFET gave precise measurements of prescribed dose. However, TLD measurement showed significant increased skin dose of cGy as compared to either prescribed dose or MOSFET group. MOSFET dosimeters provide superior dose accuracy for skin dose measurement in TBI as compared with TLD.

  11. Personal exposure control using TLD

    International Nuclear Information System (INIS)

    Ishiguro, Hideharu; Takeda, Shinso

    1979-01-01

    In the Tokai Works of the Power Reactor and Nuclear Fuel Development Corporation (PNC), for personal exposure control, the switching from film badges to TLD badges (and also finger-ring type local dosimeters) was made in fiscal 1974. The facilities involved are a fuel reprocessing plant, a PuO 2 -UO 2 mixed fuel production facility, and a centrifugal uranium enrichment development facility. The types of radiation concerned are various, such as γ(x), β and n. The situation of personal exposure control with TLD and the dose evaluation methods for respective radiations are explained. The number of personnel subject to exposure control, including transient people, is about 2500 - 3000 per three months. The TLD badges used are a special PNC type with TLDs to measure separately γ(x), β and n. With casings made of ABS resin, the external dimensions are 76 mm x 46 mm. (J.P.N.)

  12. Study of teflon pads as high doses dosemeters

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2013-01-01

    The aim of this work is to study the Teflon, which is used as a binder in the manufacture of dosimetric tablets, for the feasibility of this material as high dose dosemeter. In this paper we used the technique of thermally stimulated luminescence (OSL) to characterize the dosimetric properties of Teflon. Teflon samples were exposed to different doses of radiation, using a source of gamma radiation ( 60 Co). It was obtained dose-response curve between 100 Gy to 50 kGy and reproducibility of OSL response. The preliminary results show that Teflon is a useful material to high dose dosimetry

  13. Evaluation of film dosemeters by linear programming

    International Nuclear Information System (INIS)

    Kragh, P.; Nitschke, J.

    1992-01-01

    An evaluation method for multi-component dosemeters is described which uses linear programming in order to decrease the dependence on energy and direction. The results of this method are more accurate than those obtained with the evaluation methods so far applied in film dosimetry. In addition, systematic errors can be given when evaluating individual measurements. Combined linear programming, as a special case of the presented method, is described taking a film dosemeter of particular type as an example. (orig.) [de

  14. Dosemeter calibration in X-ray and in cobalt-60

    International Nuclear Information System (INIS)

    Silva, T.A. da

    1988-01-01

    Some tests about quality security for clinical dosemeter calibration in secondary standard dosimetry laboratory are described. The tests in gama calibration system, in X-ray calibration, in secondary standard dosimeter, in the dosemeter that will be calibrated, during the calibration and after the calibration are shown. (C.G.C.) [pt

  15. How to diagnose any type of TLD Reader?; Como diagnosticar cualquier tipo de TLD Reader?

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, Manuel Lopez; Garcia, Jose A. Tamayo; Gil, Alex Vergara; Lores, Stefan Gutierrez; Acosta, Andry Romero; Villanueva, Gilberto Alonso, E-mail: manolo@cphr.edu.cu, E-mail: jotag@cphr.edu.cu, E-mail: alex@cphr.edu.cu, E-mail: stefan@cphr.edu.cu, E-mail: andy@cphr.edu.cu, E-mail: gilberto@cphr.edu.cu [Centro de Proteccion e Higiene de las Radiaciones (CPHR), La Habana (Cuba)

    2013-07-01

    The acquisition of know how of practical experiences obtained in the repair and maintenance of readers TLD RADOS for five years of work and the request by the International Atomic Energy for signing new Research Contracts (CRP), made possible the CRP 13328, in which the specialist is committed in the course of a year, to deliver educational software in order to train personnel associated with the operation of the TLD readers RADOS. Due to the importance of continuous transfer of knowledge for new generations of technicians and specialists who join our laboratories, the idea came when the first interactive CD that grouped 19 videos, divided into three blocks was ready: learning, repair and maintenance; it was suggested to expand the training for any TLD reader. Thus a much more complete than the first version package emerged. 7 cases were subsequently published in an IAEA TECDOC, 1599 were included.

  16. Low-energy x-ray dosimetry studies (7 to 17.5 keV) with synchroton radiation

    International Nuclear Information System (INIS)

    Ipe, N.E.; Bellamy, H.; Flood, J.R.

    1995-06-01

    Unique properties of synchrotron radiation (SR), such as its high intensity, brightness, polarization, and broad spectral distribution (extending from x-ray to infra-red wavelengths) make it an attractive light source for numerous experiments. As SR facilities are rapidly being built all over the world, they introduce the need for low-energy x-ray dosemeters because of the potential radiation exposure to experimenters. However, they also provide a unique opportunity for low-energy x-ray dosimetry studies because of the availability of monochromatic x-ray beams. Results of such studies performed at the Stanford Synchrotron Radiation Laboratory are described. Lithium fluoride TLDs (TLD-100) of varying thicknesses (0.015 to 0.08 cm) were exposed free in air to monochromatic x-rays (7 to 17.5 keV). These exposures were monitored with ionization chambers. The response (nC/Gy) was found to increase with increasing TLD thickness and with increasing beam energy. A steeper increase in response with increasing energy was observed with the thicker TLDs. The responses at 7 and 17.5 keV were within a factor of 2.3 and 5.2 for the 0.015 and 0.08 cm-thick TLDs, respectively. The effects of narrow (beam size smaller than the dosemeter) and broad (beam size larger than the dosemeter) beams on the response of the TLDs are also reported

  17. The influence of the energy distribution of workplace fields on neutron personal dosemeter reading

    International Nuclear Information System (INIS)

    Tanner, R.J.; Thomas, D.J.; Bartlett, D.T.; Hager, L.G.; Horwood, N.A.

    2002-01-01

    Variations in the energy dependence of response of neutron personal dosemeters cause systematic errors in the readings obtained in workplace fields. The magnitude of these errors has been determined theoretically by folding measured and calculated workplace energy distributions with dosemeter response functions, to determine the response of a given personal dosemeter in that field. These results have been analysed with consideration of the dosemeter response to various calibration spectra, and with reference to different workplaces. The dosemeters in the study are discussed in terms of the workplaces for which they can be suitably calibrated. Deficiencies in the published neutron energy distributions are identified

  18. In vivo dosimetry using thermoluminescent detector in cancer therapy of head and neck

    International Nuclear Information System (INIS)

    Viegas, Claudio C.B.; Batista, D.V.; Campos, A.M.; Lopes, R.T.

    2002-01-01

    The viability and implementation of a routine in vivo dosimetry, using thermoluminescent dosemeters (TLD), at the radiotherapy section of the National Institute of Cancer in Brazil, in the case of head and neck treatment is shown. In order to reach that aim, the characteristics of the response of the LiF:Mg;Ti (TLD-100) thermoluminescent detectors in powder form were determined. The performed of this detector for in vivo dosimetry was testes using an RANDO Alderson anthropomorphic phantom and, once their adequability proved for the kind of measurements proposed , it was used for dose assessment in the case of tumour treatments in the head and neck regions, for Cobalt-60 irradiations. (author)

  19. Remote system for measurement of radon alpha emitter for population safety guards

    International Nuclear Information System (INIS)

    Jesus, Vasquez; Sajo-Bohus, Laszlo; Palacios, Daniel; Barros, Haydn

    2013-01-01

    The objective of this research project is to study the OSL properties for high doses of dosemeters traditionally applied in thermoluminescent dosimetry (TL), as CaF2: Dy (TLD 200) and CaF2: Mn (TLD 400), and thus verify the applicability of OSL technique in high-dose dosimetry

  20. Remote system for measurement of radon alpha emitter for population safety guards; Sistema remoto de medicion de radon alfa emisor para la salvaguarda poblacional-3599

    Energy Technology Data Exchange (ETDEWEB)

    Jesus, Vasquez, E-mail: jesus.vasguez@lnl.infn.it [Istituto Nazionale di Fisica Nucleare, Legnaro (Italy). Laboratorio Nazionale di Legnaro; Sajo-Bohus, Laszlo; Palacios, Daniel; Barros, Haydn, E-mail: sajobohus@gmail.com, E-mail: sanjuro.perdomo@gmail.com, E-mail: lab.nuclear@gmail.com [Universidad Simon Bolivar (USB), Caracas (Venezuela, Bolivarian Republic of). Laboratorio de Fisica Nuclear

    2013-07-01

    The objective of this research project is to study the OSL properties for high doses of dosemeters traditionally applied in thermoluminescent dosimetry (TL), as CaF2: Dy (TLD 200) and CaF2: Mn (TLD 400), and thus verify the applicability of OSL technique in high-dose dosimetry.

  1. Dosimetric of extremities with Dosemeters thermoluminescent in Cuba

    International Nuclear Information System (INIS)

    Molina Perez, D.; Diaz Bernal, E.; Vera Alonso, L.

    1998-01-01

    From final of the year 1995 in the CPHR implement the service of monitoring of the extremities using Dosemeter thermoluminescent (TL). The dosemeter consists on a metallic ring with a circular hole where a detector of LiF:Mg,Ti is placed (model JR1152C) of 5x5x0.9 mm 3 , covered by a fine layer of polyethylene. In the work the characteristic dosimetric as of the dosemeter is studied it satisfies the main requirements for their use in the monitoring from the exhibition to radiation photonic of the extremities. The doses are also presented registered during the first two years of operation of the service. The results obtained until the moment point out to you practice them of nuclear medicine, radiotherapy and production of substances radioactive how as of more contribution

  2. Automated read-out of thermoluminescence dosemeters in a centralized individual monitoring service

    International Nuclear Information System (INIS)

    Toivonen, M.

    The organizational problems in maintaining centralized individual monitoring service with erasable and re-usable dosemeters are evaluated. Design criteria for an automated thermoluminescence reader are laid down. It is characteristic for the planning of the monitoring system that the issuing of dosemeters can be arranged without having two dosemeters for each worker. A home made reader designed to fullfil these criteria is presented. The use of a standard barcode and a standard optical barcode reader in identification of dosemeters is described. A method of using a minicomputer in preparing the self-fastening identification labels, in printing mailing lists and in printing results is described

  3. A study of the irradiation temperature coefficient for L-alanine and DL-alanine dosemeters

    International Nuclear Information System (INIS)

    Desrosiers, M. F.; Lin, M.; Cooper, S. L.; Cui, Y.; Chen, K.

    2006-01-01

    Alanine dosimetry is now well established both as a reference and routine dosemeter for industrial irradiation processing. Accurate dosimetry under the relatively harsh conditions of industrial processing requires a characterisation of the parameters that influence the dosemeter response. The temperature of the dosemeter during irradiation is a difficult quantity to measure so that the accuracy of the temperature coefficient that governs the dosemeter response becomes a critical factor. Numerous publications have reported temperature coefficients for several types of alanine dosemeters. The observed differences in the measured values were commonly attributed to the differences in the polymer binder or the experimental design of the measurement. However, the data demonstrated a consistent difference in the temperature coefficients between L-alanine and DL-alanine. Since there were no commonalities in the dosemeter composition or the measurement methods applied, a clear conclusion is not possible. To resolve this issue, the two isomeric forms of alanine dosemeters were prepared and irradiated in an identical manner. The results indicated that the DL-alanine temperature coefficient is more than 50% higher than the L-alanine temperature coefficient. (authors)

  4. Disparidades en eficiencia técnica e influencia de las infraestructuras sobre la convergencia en eficiencia en México

    Directory of Open Access Journals (Sweden)

    Osvaldo U. Becerril-Torres

    2010-06-01

    Full Text Available El objetivo de este trabajo es identificar las disparidades en eficiencia técnica y la influencia de las infraestructuras sobre la convergencia en eficiencia para las entidades federativas de México. Para ello, se ha estimado una función de producción translogarítmica siguiendo el modelo de Battese y Coelli (1995. Los resultados muestran que la inversión realizada ha permitido incrementar la eficiencia en el uso de los factores y revelar que existen posibilidades de incrementar el ritmo de crecimiento. Mediante el análisis de convergencia se observa un acercamiento, que es más intensivo entre grupos de entidades federativas, e influido positivamente por las infraestructuras.

  5. The IAEA/WHO TLD postal programme for radiotherapy hospitals

    International Nuclear Information System (INIS)

    Izewska, J.; Andreo, P.

    2000-01-01

    Since 1969 the International Atomic Energy Agency (IAEA), together with the World Health Organization (WHO), has performed postal TLD audits to verify the calibration of radiotherapy beams in developing countries. A number of changes have recently been implemented to improve the efficiency of the IAEA/WHO TLD programme. The IAEA has increased the number of participants and reduced significantly the total turn-around time to provide results to the hospitals within the shortest possible time following the TLD irradiations. The IAEA has established a regular follow-up programme for hospitals with results outside acceptance limits of ±5%. The IAEA has, over 30 years, verified the calibration of more than 3300 clinical photon beams at approximately 1000 radiotherapy hospitals. Only 65% of those hospitals who receive TLDs for the first time have results within the acceptance limits, while more than 80% of the users that have benefited from a previous TLD audit are successful. The experience of the IAEA in TLD audits has been transferred to the national level. The IAEA offers a standardized TLD methodology, provides Guidelines and gives technical back-up to the national TLD networks. The unsatisfactory status of the dosimetry for radiotherapy, as noted in the past, is gradually improving however, the dosimetry practices in many hospitals in developing countries need to be revised in order to reach adequate conformity to hospitals that perform modern radiotherapy in Europe, USA and Australia. (author)

  6. A new fully automated TLD badge reader

    International Nuclear Information System (INIS)

    Kannan, S.; Ratna, P.; Kulkarni, M.S.

    2003-01-01

    At present personnel monitoring in India is being carried out using a number of manual and semiautomatic TLD badge Readers and the BARC TL dosimeter badge designed during 1970. Of late the manual TLD badge readers are almost completely replaced by semiautomatic readers with a number of performance improvements like use of hot gas heating to reduce the readout time considerably. PC based design with storage of glow curve for every dosimeter, on-line dose computation and printout of dose reports, etc. However the semiautomatic system suffers from the lack of a machine readable ID code on the badge and the physical design of the dosimeter card not readily compatible for automation. This paper describes a fully automated TLD badge Reader developed in the RSS Division, using a new TLD badge with machine readable ID code. The new PC based reader has a built-in reader for reading the ID code, in the form of an array of holes, on the dosimeter card. The reader has a number of self-diagnostic features to ensure a high degree of reliability. (author)

  7. Characteristics of dosemeter types for skin dose measurements in practice

    International Nuclear Information System (INIS)

    Van, D. J.; Bosmans, H.; Marchal, G.; Wambersie, A.

    2005-01-01

    A growing number of papers report deterministic effects in the skin of patients who have undergone interventional radiological procedures. Dose measurements, and especially skin dose measurements, are therefore increasingly important. Methods and acceptable dosemeters are, however, not clearly defined. This paper is the result of a literature overview with regard to assessing the entrance skin dose during radiological examinations by putting a dosemeter on the patient's skin. The relevant intrinsic characteristics, as well as some examples of clinical use of the different detector types, are presented. In this respect, thermoluminescence, scintillation, semiconductor and film dosemeters are discussed and compared with respect to their practical use. (authors)

  8. Thermoluminescence fast neutron dosimetry by laser heating

    International Nuclear Information System (INIS)

    Mathur, V.K.; Brown, M.D.; Braeunlich, P.

    1984-01-01

    Heating rates in excess of 10 4 K.sec -1 have been achieved for thin layers of TL dosemeters by laser heating. The high heating rate improves the signal to noise ratio up to a factor of 10 3 . Thus sensitive thin film fast neutron dosemeters with negligible self-shielding have become a practical reality. Thin samples of CaSO 4 :Dy have been investigated for their response to fast neutrons from a Pu-Be source and a 14.6 MeV neutron generator by using a hydrogenous radiator. A 15 watt CO 2 laser was focussed on the thin TLD layer to a spot size of less than 1 mm to heat it. An exposure of a few tens of milliseconds was sufficient to obtain a TLD curve, which was displayed and processed by a wave form digitiser. The laser spot could be scanned over the TLD sample by a x-y positioner and a large number of observations were obtained on each sample. Preliminary results show that it is possible to obtain a figure of merit of approx. 5% in a mixed n, γ field. A practical design for a fast neutron dosemeter is proposed. (author)

  9. Numerical and experimental results of the operational neutron dosemeter 'Saphydose-N'

    International Nuclear Information System (INIS)

    Lahaye, T.; Chau, Q.; Menard, S.; Ndontcheung-Moyo, M.; Bolognese-Milsztajn, T.; Rannou, A.

    2004-01-01

    Since 1993, the Inst. for Radiological Protection and Nuclear Safety (IRSN) has lead, in association with Electricite de France (EDF), a R and D study of a neutron personal electronic dosemeter. This dosemeter, called 'Saphydose-N', is manufactured by the SAPHYMO company. This paper presents first the optimisation of some detector components using Monte Carlo calculations, and second the test of the manufactured Saphydose-N under radiation following the IEC 1323 standard's recommendations for active personal neutron dosemeters. The measurements with the manufactured dosemeter were performed on the one hand at PTB (Physikalisch-Technische Bundesanstalt) in mono-energetic neutron fields and, on the other hand at IRSN in neutron fields generated by a thermal facility (SIGMA), radionuclide ISO sources and a realistic spectrum (CANEL/T400). The manufactured dosemeter Saphydose-N was also tested during measurement campaigns of the European programme EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields') at different nuclear workplaces. The study showed that Saphydose-N complies with the recommendations of standard IEC 1323 and can be used at any workplace with no previous knowledge of the neutron field characteristics. (authors)

  10. Intercomparison On Depth Dose Measurement

    International Nuclear Information System (INIS)

    Rohmah, N; Akhadi, M

    1996-01-01

    Intercomparation on personal dose evaluation system has been carried out between CSRSR-NAEA of Indonesia toward Standard Laboratory of JAERI (Japan) and ARL (Australia). The intercomparison was in 10 amm depth dose measurement , Hp (10), from the intercomparison result could be stated that personal depth dose measurement conducted by CSRSR was sufficiently good. Deviation of dose measurement result using personal dosemeter of TLD BG-1 type which were used by CSRSR in the intercomparison and routine photon personal dose monitoring was still in internationally agreed limit. Maximum deviation of reported doses by CSRSR compared to delivered doses for dosemeter irradiation by JAERI was -10.0 percent and by ARL was +29 percent. Maximum deviation permitted in personal dose monitoring is ± 50 percent

  11. The NRPB nuclear emission dosemeter

    International Nuclear Information System (INIS)

    Bartlett, D.T.; Bird, T.V.; Miles, J.C.H.

    1980-03-01

    The NRPB nuclear emulsion dosemeter is designed such that the thermal neutron response is similar to the fast neutron response. This report gives details of the dependence of response on incident neutron energy and on neutron angle of incidence. (author)

  12. Eye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects of Hp(3) monitoring. A 2015 review

    International Nuclear Information System (INIS)

    Carinou, Eleftheria; Ferrari, Paolo; Bjelac, Olivera Ciraj; Gingaume, Merce; Merce, Marta Sans; O’Connor, Una

    2015-01-01

    A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended. (review)

  13. Application of chemical dosemeters during the irradiation of agricultural products

    Energy Technology Data Exchange (ETDEWEB)

    Kovacs, A; Stenger, V; Foeldiak, G [Magyar Tudomanyos Akademia, Budapest. Izotopintezete

    1983-09-01

    The joint recommedation by the FAO, WHO and IAEA in 1981 proposed the unrestricted permission of food irradiation under the dose value of 10 kGy (1 Mrd). The chemical dosemeters presented in the paper cover the dose range of 30 Gy to 1 MGy for use to food irradiation safety measurements. The Fricke dosemeter was used in the 50-400 Gy range at radappertization operations of onion, poppy and potato. The alcoholic chlorobenzene dosemeter with oscillometric analysis was applied successfully at low (0.4-4 kGy) ranges, primarily for irradiation dose monitoring of fruits, vegetables, refrigerated poultry etc. The conductometry could be used for dosimetry in the range of 60 Gy to 1 MGy.

  14. Solid thermoluminescent dosemeter of sodium tetraborate and brazilian fluorite sensible to thermic neutrons

    International Nuclear Information System (INIS)

    Fratin, L.; Cruz, M.T. da

    1987-01-01

    The production of solid thermoluminescent dosemeters sensible to thermic neutrons is described. The stages of the production are described: vitrification of sodium tetraborate, mixture and cold pressing, syntherization. The obtention of a CaF 2 : natural dosemeter with NaCl which presents sensibility to gamma radiation similar to CaF 2 : natural dosemeter with Na 2 B 4 O 7 is studied. (M.A.C.) [pt

  15. TLD audit in the radiotherapy at the national level

    International Nuclear Information System (INIS)

    Kroutilikova, D.; Zackova, H.; Novotny, J.; Pridal, I.

    1998-01-01

    Czech legislation requires that all radiotherapy departments undertake quality independent audit annually. An authorized auditing group was created as a body of the National Radiation Protection Institute. It has been decided that TLD postal audit combined with film dosimetry would alternate with in situ audit every two or three years. For this, a local TLD measuring network has been established. The methods applied in the TLD audit were taken from EROPAQ and EURAQA projects in 1996 and modified to comply with Czech local circumstances. First TLD audits were started in February 1997. During the February to September period, 60 beams were checked: 26 Co-60 beams, 10 Cs-137 beams, 15 X-ray beams, and 9 electron beams. Details of the measurements and their results are given. (P.A.)

  16. Thermoluminescence sensitivity variations in LiF PTFE dosemeters incurred by improper handling procedures

    CERN Document Server

    Mason, E W; MacKinlay, Alistair F; Saunders, D

    1975-01-01

    A systematic study of some anomalous darkening effects and thermoluminescence sensitivity variations observed in LiF:PTFE thermoluminescent dosemeters is described. Various likely causes of such effects have been investigated. The manufacturer's recommended cleaning procedures have been found to be inadequate and, in some cases, have been found to actually promote discolouration of the dosemeters. Recommendations are given for the successful use of LiF:PTFE thermoluminescent dosemeters in personal dosimetry.

  17. A low-cost personal dosemeter based on optically stimulated luminescence (OSL) of common household salt (NaCl)

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Bulánek, Boris; Judas, Libor

    2016-01-01

    Salt represents a radiation sensitive material that can be used for dosimetry. The objective of this experimental study was to test a low-cost salt dosemeter that was designed for personnel that are not radiation workers, but can operate in low probability events resulting in a serious external radiation exposure. The dosemeter is based on use of optically stimulated luminescence (OSL) of a common household salt. Attention was concentrated on its energy and angular responses. The dosemeter was fixed to the ICRU slab phantom and irradiated by photons of reference radiation qualities (ISO 4037-1) with mean energies between 33 and 1250 keV. Angular response was investigated for angles of incidence from 0° to 80° for radiation qualities of N-150 (∼118 keV) and S-Cs (∼662 keV). Single-Aliquot Regenerative-dose analytical protocol was employed for dose reconstruction. The results were evaluated with respect to H_p(10) measurement. The salt dosemeter can provide reliable or reasonably conservative H_p(10) estimates in radiation fields where photon energies > 100 keV predominate, radiation incidence angles are from 0° to 80° and also for rotational geometry. Furthermore, a personal dose reconstruction trial was demonstrated. Relative deviation between the measured and reference H_p(10) values was 5.5%. A practical disadvantage of the method is the more demanding analytical protocol. - Highlights: • Common salt has a considerable potential for dosimetry based on use of OSL. • A simple salt personal dosemeter was designed and tested. • Photon energy and angular responses were satisfactory for purposes of accidental dosimetry. • Dose reconstruction trial proved the potential for reliable estimate of personal doses.

  18. EURADOS intercomparison 2012 for neutron dosemeters

    International Nuclear Information System (INIS)

    Fantuzzi, E.; Chevallier, M.A.; Cruz-Suarez, R.; Luszik-Bhadra, M.; Mayer, S.; Thomas, D.J.; Tanner, R.; Vanhavere, F.

    2014-11-01

    EURADOS, within the work performed by Working Group 2 - Harmonization of Individual Monitoring in Europe, has started a self-sustained programme of regular intercomparisons and has successfully executed three intercomparisons for whole body photon dosemeters (IC2008, IC2010, IC2012) and one intercomparison for extremity dosemeters for photon and beta fields (IC2009). In 2012, the EURADOS intercomparison IC2012n was launched for personal neutron dosemeters routinely used to measure personal dose equivalent, Hp(10), in individual monitoring. No systems under development were allowed to participate. IC2012n was carried out by a EURADOS nominated Organization Group (OG) consisting of: Marie- Anne Chevallier (IRSN, F), Rodolfo Cruz-Suarez (IAEA, UN-Vienna), Marlies Luszik-Bhadra (PTB, D), Sabine Mayer (PSI, CH), David J. Thomas (NPL, UK), Rick Tanner (PHE, UK), Filip Vanhavere (SCK-CEN, B) led by a Coordinator, Elena Fantuzzi (ENEA, I). 31 participants registered for the comparison, with 34 dosimetry systems. In total 816 dosemeters were irradiated in selected neutron fields on an ISO slab phantom. The irradiations were performed at 2 European accredited laboratories which are both National Primary Metrology Laboratories for ionizing radiation: NPL (National Physical Laboratory, UK) and PTB (Physikalisch-Technische Bundesanstalt, D). All irradiations were carried out according to the irradiation plan developed by the OG. The overall results show that most, although not all, dosimetric systems perform acceptably well (within a factor of 2) for irradiations with a bare radionuclide source ( 252 Cf at 0 ), whilst more than half of the systems underestimate the reference value for irradiations from non-normal angles of incidence irradiations ( 252 Cf at 45 ) or for simulated workplace fields ( 252 Cf(D 2 O) or 252 Cf source behind a shadow cone). The performance for 250 keV mono-energetic neutron irradiations varies mainly reflecting the detection principle on which the

  19. Traceability of a panoramic gamma irradiator using different TLD systems as transfer Instruments; Trazabilidad de un irradiador panoramico mediante sistemas de dosimetria TL

    Energy Technology Data Exchange (ETDEWEB)

    Romero, A. M.; Saez, J. C

    1994-07-01

    This work shows the calibration in terms of the new operational radiological quantities Hp (10) and H(10) for different TLD systems (Harshaw TLD-100 and Panasonic UD-002) used in personal and environmental monitoring. The irradiations were performed in the Spanish Reference Laboratory in radiation protection levels, managed by the CIEMAT Metrology of ionizing radiations Unit. With those data, different calibrations of a panoramic gamma irradiator in terms of the radiological quantity for unit of time were established, providing the traceability of the irradiator to the Reference Laboratory using the corresponding TLD systems as transfer instruments. (Author) 9 refs.

  20. Traceability of a panoramic gamma irradiator using different TLD systems as transfer instruments; Trazabilidad de un irradiador panoramico mediante sistemas de dosimetria TL

    Energy Technology Data Exchange (ETDEWEB)

    Romero, A.M.; Saez, J.C.

    1994-08-01

    This work shows the calibration in terms of the new operational radiological quantities Hp(10) and H*(10) for different TLD systems (Harshaw TLD-100 and Panasonic UD-802) used in personal and environmental monitoring. The irradiations were performed in the Spanish Reference Laboratory in radiation protection levels, managed by the CIEMAT Metrology of ionizing radiations Unit. With these data, different calibrations of a panoramic gamma irradiator in terms of the radiological quantity for unit of time were established, providing the traceability of the irradiator to the Reference Laboratory using the corresponding TLD systems as transfer instruments. (Author) 9 refs.

  1. Thermoluminescent dosimeters (TLD) quality assurance network in the Czech Republic.

    Science.gov (United States)

    Kroutilķková, Daniela; Novotný, Josef; Judas, Libor

    2003-02-01

    The Czech thermoluminescent dosimeters (TLD) quality assurance network was established in 1997. Its aim is to pursue a regular independent quality audit in Czech radiotherapy centres and to support state supervision. The audit is realised via mailed TL dosimetry. The TLD system consists of encapsulated LiF:Mg,Ti powder (type MT-N) read with Harshaw manual reader model 4000. Basic mode of the TLD audit covers measurements under reference conditions, specifically beam calibration checks for all clinically used photon and electron beams. Advanced mode consists of measurements under both reference and non-reference conditions using a solid multipurpose phantom ('Leuven phantom') for photon beams. The radiotherapy centres are instructed to deliver to the TLD on central beam axis absorbed dose of 2 Gy calculated with their treatment planning system for a particular treatment set-up. The TLD measured doses are compared with the calculated ones. Deviations of +/-3% are considered acceptable for both basic and advanced mode of the audit. There are 34 radiotherapy centres in the Czech Republic. They undergo the basic mode of the TLD audit regularly every 2 years. If a centre shows a deviation outside the acceptance level, it is audited more often. Presently, most of the checked beams comply with the acceptance level. The advanced TLD audit has been implemented as a pilot study for the present. The results were mostly within the acceptance limit for the measurements on-axis, whereas for off-axis points they fell beyond the limit more frequently, especially for set-ups with inhomogeneities, oblique incidence and wedges. The results prove the importance of the national TLD quality assurance network. It has contributed to the improvement of clinical dosimetry in the Czech Republic. In addition, it helps the regulatory authority to monitor effectively and regularly radiotherapy centres.

  2. Thermoluminescent dosimeters (TLD) quality assurance network in the Czech Republic

    International Nuclear Information System (INIS)

    Kroutilikova, Daniela; Novotny, Josef; Judas, Libor

    2003-01-01

    Introduction: The Czech thermoluminescent dosimeters (TLD) quality assurance network was established in 1997. Its aim is to pursue a regular independent quality audit in Czech radiotherapy centres and to support state supervision. Materials and methods: The audit is realised via mailed TL dosimetry. The TLD system consists of encapsulated LiF:Mg,Ti powder (type MT-N) read with Harshaw manual reader model 4000. Basic mode of the TLD audit covers measurements under reference conditions, specifically beam calibration checks for all clinically used photon and electron beams. Advanced mode consists of measurements under both reference and non-reference conditions using a solid multipurpose phantom ('Leuven phantom') for photon beams. The radiotherapy centres are instructed to deliver to the TLD on central beam axis absorbed dose of 2 Gy calculated with their treatment planning system for a particular treatment set-up. The TLD measured doses are compared with the calculated ones. Deviations of ±3% are considered acceptable for both basic and advanced mode of the audit. Results: There are 34 radiotherapy centres in the Czech Republic. They undergo the basic mode of the TLD audit regularly every 2 years. If a centre shows a deviation outside the acceptance level, it is audited more often. Presently, most of the checked beams comply with the acceptance level. The advanced TLD audit has been implemented as a pilot study for the present. The results were mostly within the acceptance limit for the measurements on-axis, whereas for off-axis points they fell beyond the limit more frequently, especially for set-ups with inhomogeneities, oblique incidence and wedges. Conclusions: The results prove the importance of the national TLD quality assurance network. It has contributed to the improvement of clinical dosimetry in the Czech Republic. In addition, it helps the regulatory authority to monitor effectively and regularly radiotherapy centres

  3. A TLD reader for wide range in situ dose measurement

    International Nuclear Information System (INIS)

    Deme, S; Apathy, I.; Bodnar, L.; Csoeke, A.; Hejja, I.

    1998-01-01

    A portable thermoluminescent dosemeter reader suitable for reading at the site of exposure is described. The instrument consists of a glass bulb containing the CaSO 4 :Dy thermoluminescent material laminated to the surface of an electrically heated resistive metal plate. The bulb is encapsulated in a cylindrical, pen-like metal holder made of aluminium. A one-wire-port integrated electronic programmable memory chip mounted inside the holder contains the identification code and the individual calibration parameters of the dosemeter. The aperture of the holder is normally covered by a stainless steel tube to protect the bulb from light and mechanical shocks. The tube slips backwards automatically when the dosemeter is inserted into the reader. The system is used by the Hungarian nuclear power plant. (M.D.)

  4. Experimental determination of relative light conversion factors of TLD-100 for protons with energies from 2.0 to 9.0 MeV

    International Nuclear Information System (INIS)

    Schmidt, P.; Fellinger, J.; Henniger, J.; Huebner, K.

    1988-01-01

    The efficiency of thermoluminescent (TL) detectors to heavy charged particles is described by the so-called light conversion factor η. Relative light conversion factors for protons, alphas and heavier recoils are needed for the calculation of the neutron sensitivity of TL detectors. Such light conversion factors can be determined experimentally. In this paper a method is presented for the experimental determination of relative light conversion factors. Using the experimental arrangement described, relative light conversion factors for LiF material (TLD-100) for protons were determined. In LiF the relative main peak (peak V) efficiency is always lower than 1. It increases with increasing proton energy whereas the relative efficiency of the high temperature peak (peak VI) shows an opposite dependence on the proton energy. Relative light conversion factors for peak VI clearly exceed 1. (orig.)

  5. The TL fluence response to heavy charged particles using the track interaction model and track structure information

    International Nuclear Information System (INIS)

    Rodriguez-Villafuerte, M.; Avila, O.

    2002-01-01

    The extended track interaction model, ETIM, has recently been proposed to explain the TLD-100 fluence response of peak 5 to heavy ions. This model includes the track structure information through the use of the luminescent-centre occupation probability obtained from radial dose distributions produced by the ions as they travel through the dosemeter. In this work an implementation of ETIM using Monte Carlo techniques is presented. The simulation was applied to calculate the response of peak 5 of both sensitised and normal TLD-100 crystals to 2.6 and 6.8 MeV 4 He ions. The simulation shows that the TL-fluence response has a strong dependence on ion energy, in disagreement with experimental observations. In spite of this, good agreement between the simulated TL-fluence response calculated for the 6.8 MeV 4 He radial distributions and the experimental data for the two energies was achieved. (author)

  6. Study of physical factors affecting the TLD readout

    International Nuclear Information System (INIS)

    Ahmed, Amira Abd Elrhman Ebrahim

    2015-10-01

    The aim of the study was to study the effects of physical factors in TLD reading. The dosimeters have been irradiated with x rays of (0.5 mGy to 5 mGy) using plastic holder with Aluminum filters with dimensions 1.5 x 0.8 mm and 0.5 mm in thickness to obtain the equivalent dose Hp (10) flux of nitrogen gas and annealing after data collection by TLD Reader Analyzer 04 (Version 0.9.400 micro lab (krakow 2012). The count and dose analysis shows that; The count/s given by TLD appears to be higher in case of using filtration which was 7189.9 eps in contrast with reading without filter which was 4055.8 eps. There was proportional linear relationship between the applied dose and the TLD count for both cases with and without filter. And the correlation could be fitted in the form of equations: y=423.9 x + 1023 and y = 432.5 x + 405.3 for filtered and y refers to count/s. Such increment in count is ascribed to increasing applied radiation dose as well it indicates and confirms the linearity of TLD in measuring the radiation dose since R 2 = 0.9. However the count with filter for the applied radiation dose in mGy was greater than that without filter. The that measured with pellets annealing (reading of zero doses). TLD pellets reading without zero dose measurement usually gives greater dose ( 441.8 and 563.6 μGy) relative to the case where the zero doses have been measured which were 289.6 and 429.2 μGy, respectively. While the effect of using filtration is so obvious and leads to increase of zero dose, respectively relative to dose s of un reading of zero dose, and reading of zero dose, but without filter.(Author)

  7. Analysis of uncertainties in the IAEA/WHO TLD postal dose audit system

    Energy Technology Data Exchange (ETDEWEB)

    Izewska, J. [Department of Nuclear Sciences and Applications, International Atomic Energy Agency, Wagramer Strasse 5, Vienna (Austria)], E-mail: j.izewska@iaea.org; Hultqvist, M. [Department of Medical Radiation Physics, Karolinska Institute, Stockholm University, Stockholm (Sweden); Bera, P. [Department of Nuclear Sciences and Applications, International Atomic Energy Agency, Wagramer Strasse 5, Vienna (Austria)

    2008-02-15

    The International Atomic Energy Agency (IAEA) and the World Health Organisation (WHO) operate the IAEA/WHO TLD postal dose audit programme. Thermoluminescence dosimeters (TLDs) are used as transfer devices in this programme. In the present work the uncertainties in the dose determination from TLD measurements have been evaluated. The analysis of uncertainties comprises uncertainties in the calibration coefficient of the TLD system and uncertainties in factors correcting for dose response non-linearity, fading of TL signal, energy response and influence of TLD holder. The individual uncertainties have been combined to estimate the total uncertainty in the dose evaluated from TLD measurements. The combined relative standard uncertainty in the dose determined from TLD measurements has been estimated to be 1.2% for irradiations with Co-60 {gamma}-rays and 1.6% for irradiations with high-energy X-rays. Results from irradiations by the Bureau international des poids et mesures (BIPM), Primary Standard Dosimetry Laboratories (PSDLs) and Secondary Standards Dosimetry Laboratories (SSDLs) compare favourably with the estimated uncertainties, whereas TLD results of radiotherapy centres show higher standard deviations than those derived theoretically.

  8. Solid thermoluminescent dosemeter of sodium tetraborate and brazilian fluorite sensible to thermal neutrons

    International Nuclear Information System (INIS)

    Fratin, L.; Cruz, M.T. da

    1987-01-01

    A solid termoluminescent dosemeter of sodium tetraborate and brazilian fluorite sensible to thermal neutrons is described. The nuclears reactions 1) 10 B + n → 7 Li + He + Q1 (6,1%) where: Q1=2,79 MeV and Eα1 = 1,758 MeV and 2) 10 B + n → 7 Li* + 4 He + Q2 (93,9%) where: Q2 = 2,316 MeV and E2α 2 = 1,474 MeV are responsible by the thermoluminescent response of the thermal neutrons dosemeters. The stages in the fabrication process of this dosemeter of which are:1) sodium tetraborate vitrification, 2) mixture and pressing 3) sintering are cited. The obtainment of a natural fluorite dosemeter with sodium chloride is also shown. (C.G.C.) [pt

  9. Una medida de eficiencia de mercado. Un enfoque de teoría de la información

    Directory of Open Access Journals (Sweden)

    Reyna Susana García Ruiz

    2014-01-01

    Full Text Available En este trabajo, con base en el concepto de entropía de Shan-non, se propone una medida de eficiencia de mercado que uti-liza la función de densidad empírica de los rendimientos comoalfabeto para calcular la entropía del sistema y proveer con ellouna medida de eficiencia de mercado. Se demuestra que bajociertas condiciones de ergodicidad y de estacionariedad la en-tropía muestral converge a la entropía del estado dominante,lo que valida el uso de la entropía muestral como medida deeficiencia del sistema. Asimismo, se demuestra que la medidapropuesta es consistente con algunos de los axiomas de Artz-neret al.(1999 acerca de una medida coherente de riesgo. Porúltimo, con fines ilustrativos, se llevan a cabo varias aplicacio-nes de la medida de eficiencia propuesta a distintos mercadosde capitales: DJIA, S&P500, FTSE100 e IPC.

  10. Development and testing of a thermoluminescent dosemeter for mixed neutron-photon-beta radiation fields

    International Nuclear Information System (INIS)

    Zummo, J.J.; Liu, J.C.

    1998-08-01

    A new four-element thermoluminescent (TL) dosemeter and dose evaluation algorithm have been developed and tested to better characterize personnel exposure in mixed neutron-photon-beta radiation fields. The prototype dosemeter is based on a commercially available TL card (with three LiF-7 chips and one LiF-6 chip) and modified filtration elements. The new algorithm takes advantage of the high temperature peak characteristics of the LiF-6 element to better quantify the neutron dose component. The dosemeter was tested in various radiation fields, consisting of mixtures of two radiation types typically used for dosemeter performance testing, as well as mixtures of three radiation types to simulate possible exposure conditions. The new dosemeter gave superior performance, based on the tolerance levels, when using the new algorithm as compared to a conventional algorithm that did not use the high temperature peak methodology. The limitations and further improvements are discussed

  11. Automated TLD system for gamma radiation monitoring

    International Nuclear Information System (INIS)

    Nyberg, P.C.; Ott, J.D.; Edmonds, C.M.; Hopper, J.L.

    1979-01-01

    A gamma radiation monitoring system utilizing a commercially available TLD reader and unique microcomputer control has been built to assess the external radiation exposure to the resident population near a nuclear weapons testing facility. Maximum use of the microcomputer was made to increase the efficiency of data acquisition, transmission, and preparation, and to reduce operational costs. The system was tested for conformance with an applicable national standard for TLD's used in environmental measurements

  12. Neutron-photon mixed field dosimetry by TLD-700 glow curve analysis and its implementation in dose monitoring for Boron Neutron Capture Therapy (BNCT) treatments

    Energy Technology Data Exchange (ETDEWEB)

    Boggio, E. F.; Longhino, J. M. [Centro Atomico Bariloche, Departamento de Fisica de Reactores y Radiaciones / CNEA, Av. E. Bustillo Km 9.5, R8402AGP San Carlos de Bariloche (Argentina); Andres, P. A., E-mail: efboggio@cab.cnea.gov.ar [Centro Atomico Bariloche, Division Proteccion Radiologica / CNEA, Av. E. Bustillo Km 9.5, R8402AGP San Carlos de Bariloche (Argentina)

    2015-10-15

    BNCT is a cancerous cells selective, non-conventional radiotherapy modality to treat malignant tumors such as glioblastoma, melanoma and recurrent head and neck cancer. It consists of a two-step procedure: first, the patient is injected with a tumor localizing drug containing a non-radioactive isotope (Boron-10) with high slow neutron capture cross-section. In a second step, the patient is irradiated with neutrons, which are absorbed by the Boron-10 agent with the subsequently nuclear reaction B- 10(n,a)Li-7, thereby resulting in dose at cellular level due to the high-Let particles. The neutron fields suitable for BNCT are characterized by high neutron fluxes and low gamma dose. Determination of each component is not an easy task, especially when the volume of measurement is quite small or inaccessible for a miniature ionization chamber, for example. A method of measuring the photon and slow neutron dose(mainly by N-14 and B-10) from the glow curve (GC) analysis of a single {sup 7}LiF thermoluminescence detector is evaluated. This method was suggested by the group headed by Dr. Grazia Gambarini. The dosemeters used were TLD-600 ({sup 6}LiF:Mg,Ti with 95.6% {sup 6}Li) and TLD-700 ({sup 7}LiF:Mg,Ti with 99.9% {sup 7}LiF) from Harshaw. Photon dose measurement using the GC analysis method with TLD-700 in mixed fields requires the relation of the two main peaks of a TLD-600 GC shape obtained from an exposition to the same neutron field, and a photon calibrated GC with TLD-700. The requirements for slow neutron dose measurements are similar. In order to properly apply the GC analysis method at the Ra-6 Research Reactor BNCT facility, measurements were carried out in a standard water phantom, fully characterized on the BNCT beam by conventional techniques (activation detectors and paired ionization chambers technique). Next, the method was implemented in whole body dose monitoring of a patient undergoing a BNCT treatment, using a Bo MAb (Bottle Manikin Absorption) phantom

  13. Calibration of a scintillation dosemeter for beta rays using an extrapolation ionization chamber

    International Nuclear Information System (INIS)

    Hakanen, A.T.; Sipilae, P.M.; Kosunen, A.

    2004-01-01

    A scintillation dosemeter is calibrated for 90 Sr/ 90 Y beta rays from an ophthalmic applicator, using an extrapolation ionization chamber as a reference instrument. The calibration factor for the scintillation dosemeter agrees with that given by the manufacturer of the dosemeter within ca. 2%. The estimated overall uncertainty of the present calibration is ca. 6% (2 sd). A calibrated beta-ray ophthalmic applicator can be used as a reference source for further calibrations performed in the laboratory or in the hospital

  14. Measurements of environmental gamma-ray spectra using a multi-element TL dosemeter

    International Nuclear Information System (INIS)

    Furuta, Sadaaki; Boetter-Jensen, L.; Nielsen, S.P.

    1986-12-01

    A method to estimate the energy distribution and dose of environmental gamma radiation was developed using a multielement TL dosemeter. Experimentally obtained energy responses from a multi-element TL dosemeter with different kinds of filters were used to calculate the energy distribution and related dose by the SAND-II computer code. The code was originally developed to estimate the neutron flux using a multiple foil activation method. Measurements were made at several locations with the multi-element TL dosemeter and comparisons were made with results from a NaI(Tl) scintillation detector and a high-pressure ionization chamber. (author)

  15. Study of analysis techniques of thermoluminescent dosimeters response

    International Nuclear Information System (INIS)

    Castro, Walber Amorim

    2002-01-01

    The Personal Monitoring Service of the Centro Regional de Ciencias Nucleares uses in its dosemeter the TLD 700 material . The TLD's analysis is carried out using a Harshaw-Bicron model 6600 automatic reading system. This system uses dry air instead of the traditional gaseous nitrogen. This innovation brought advantages to the service but introduced uncertainties in the reference of the detectors; one of these was observed for doses below 0,5 mSv. In this work different techniques of analysis of the TLD response were investigated and compared, involving dose values in this interval. These techniques include thermal pre-treatment, and different kinds of the glow curves analysis methods were investigated. Obtained results showed the necessity of developing a specific software that permits the automatic background subtraction for the glow curves for each dosemeter . This software was developed and it bean tested. Preliminary results showed the software increase the response reproducibility. (author)

  16. EURADOS intercomparison 2012 for neutron dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Fantuzzi, E. [ENEA-Radiation Protection Institute, Bologna (Italy); Chevallier, M.A. [Institut de Radioprotection et de Surete Nucleaire (IRSN), Fontenay-aux-Roses (France); Cruz-Suarez, R. [International Atomic Energy Agency, Vienna (Austria); Luszik-Bhadra, M. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Mayer, S. [Paul Scherrer Institute (PSI), Villigen (Switzerland); Thomas, D.J. [National Physical Laboratory (NPL), Teddington (United Kingdom); Tanner, R. [Public Health England, Oxon (United Kingdom); Vanhavere, F. [SCK-CEN, Belgian Nuclear Research Centre, Mol (Belgium)

    2014-11-15

    EURADOS, within the work performed by Working Group 2 - Harmonization of Individual Monitoring in Europe, has started a self-sustained programme of regular intercomparisons and has successfully executed three intercomparisons for whole body photon dosemeters (IC2008, IC2010, IC2012) and one intercomparison for extremity dosemeters for photon and beta fields (IC2009). In 2012, the EURADOS intercomparison IC2012n was launched for personal neutron dosemeters routinely used to measure personal dose equivalent, Hp(10), in individual monitoring. No systems under development were allowed to participate. IC2012n was carried out by a EURADOS nominated Organization Group (OG) consisting of: Marie- Anne Chevallier (IRSN, F), Rodolfo Cruz-Suarez (IAEA, UN-Vienna), Marlies Luszik-Bhadra (PTB, D), Sabine Mayer (PSI, CH), David J. Thomas (NPL, UK), Rick Tanner (PHE, UK), Filip Vanhavere (SCK-CEN, B) led by a Coordinator, Elena Fantuzzi (ENEA, I). 31 participants registered for the comparison, with 34 dosimetry systems. In total 816 dosemeters were irradiated in selected neutron fields on an ISO slab phantom. The irradiations were performed at 2 European accredited laboratories which are both National Primary Metrology Laboratories for ionizing radiation: NPL (National Physical Laboratory, UK) and PTB (Physikalisch-Technische Bundesanstalt, D). All irradiations were carried out according to the irradiation plan developed by the OG. The overall results show that most, although not all, dosimetric systems perform acceptably well (within a factor of 2) for irradiations with a bare radionuclide source ({sup 252}Cf at 0 ), whilst more than half of the systems underestimate the reference value for irradiations from non-normal angles of incidence irradiations ({sup 252}Cf at 45 ) or for simulated workplace fields ({sup 252}Cf(D{sub 2}O) or {sup 252}Cf source behind a shadow cone). The performance for 250 keV mono-energetic neutron irradiations varies mainly reflecting the detection

  17. Thermoluminescence dosemeter for personal dose equivalent assessment

    International Nuclear Information System (INIS)

    Silva, T.A. da; Rosa, L.A.R. da; Campos, L.L.

    1995-01-01

    The possibility was investigated of utilising a Brazilian thermoluminescence individual dosemeter, usually calibrated in terms of photon dose equivalent, for the assessment of the personal dose equivalent, H p (d), at depths of 0.07 and 10 mm. The dosemeter uses four CaSO 4 :Dy thermoluminescent detectors, between different filters, as the sensitive materials. It was calibrated in gamma and X radiation fields in the energy range from 17 to 1250 keV. Linear combinations of the responses of three detectors, in this energy range, allow the evaluation of H p (0.07) and H p (10), for radiation incidence angles varying from 0 to 60 degrees, with an accuracy better than 35%. The method is not applicable to mixed photon-beta fields. (author)

  18. How do hospital sterilisation procedures affect the response of personal extremity rings and of eye lens TL dosemeters?

    International Nuclear Information System (INIS)

    Kopec, Renata; Bubak, Anna; Budzanowski, Maciej; Sas-Bieniarz, Anna; Szumska, Agnieszka

    2016-01-01

    Stringent standards of hygiene must be applied in medical institutions, especially at operating blocks or during interventional radiology procedures. Medical equipment, including personal dosemeters that have to be worn by medical staff during such procedures, needs therefore to be sterilised. In this study, the effect of various sterilisation procedures has been tested on the dose response of extremity rings and of eye lens dosemeters in which thermoluminescent (TL) detectors (of types MTS-N and MCP-N, respectively) are used. The effects of medical sterilisation procedures were studied: by chemicals, by steam or by ultraviolet (UV), on the dose assessment by extremity rings and by eye lens dosemeters. Since it often happens that a dosemeter is accidentally machine-washed together with protective clothing, the effect of laundering on dose assessment by these dosemeters was also tested. The sterilisation by chemicals is mostly safe for TL detectors assuming that the dosemeters are waterproofed. Following sterilisation by water vapour, the response of these dosemeters diminished by some 30 %, irrespectively of the period of sterilisation; therefore, this method is not recommended. UV sterilisation can be applied to EYE-D TM eye lens dosemeters if their encapsulation is in black. The accidental dosemeter laundry in a washing machine has no impact on measured dose. (authors)

  19. C-program LINOP for the evaluation of film dosemeters by linear optimization. User manual

    International Nuclear Information System (INIS)

    Kragh, P.

    1995-11-01

    Linear programming results in an optimal measuring value for film dosemeters. The Linop program was developed to be used for linear programming. The program permits the evaluation and control of film dosemeters and of all other multi-component dosemeters. This user manual for the Linop program contains the source program, a description of the program and installation and use instructions. The data sets with programs and examples are available upon request. (orig.) [de

  20. Personal dosimetry TLD 100 in orthopedic surgeons exposed to ionizing radiation in Bogota - Colombia

    International Nuclear Information System (INIS)

    Sierra C, B. Y.; Jimenez, Y.; Plazas, M. C.; Eslava S, J.; Groot R, H.

    2014-08-01

    Orthopedic surgeons should be considered as professionals occupationally exposed to ionizing radiation, for using C arc (fluoroscope) an equipment of X type radiation emission, during surgical procedures for imaging generation. Some health institutes, use of C arc under uncontrolled circumstances, such a lack of dosimetry control, incomplete or absence of personnel protective elements and protective measures, which in turn, lead to a high exposition to the personnel. Materials and methods. Study of double match cohort by age and gender, was conducted, in four health institutions of second and third level of attention in Bogota city. Personal dosimetry measurements with TLD-100 dosimetry crystals in both cohorts and environmental dosimetry in each of operation rooms used for orthopedic procedures, were carry out during six months of follow up. Dosimetry crystals were read in a Harshaw 4500 - Bicron equipment, in the Medical Physics Laboratory of National University of Colombia. Results. Dosimetry measurements are compatibles with those of occupationally exposed personnel 3.44 mSv/6 m CI 95% (1.66-3.99), even does not overpass ICRP recommendations, are higher as were expect at the beginning of the study. The median of effective accumulative dose in thorax is 3,4 mSv CI 95% (1,66-3,99), higher in comparison with neck value 2,7 mSv CI 95% (1,73-3,80) and hand dosimetry 1,42 mSv CI 95% (0,96-2,34). Conclusions: Orthopedic surgeons should be considered occupational exposed to ionizing radiation, who has to accomplish to the radiological protection measures, dosimetric follow up and maintenance of the used X ray equipment. It was confirm throughout this study that dosimetry shows higher levels as expected at the beginning of the study, compatible with occupationally exposed personnel. (Author)

  1. Development of radiophotometric dosemeters of high sensitivity using plastic scintillators as light intensifiers

    International Nuclear Information System (INIS)

    Mesquita, C.H. de; Hamada, M.M.

    1987-01-01

    The use of rectangular plates of plastic scintillators as film holders in conventional photographic dosemeters is reported. The efficiency of their use as light converters for increase the sensitivity of these dosemeters are studied. (M.A.C.) [pt

  2. Measurement of annual dose on porcelain using surface TLD method

    International Nuclear Information System (INIS)

    Xia Junding; Wang Weida; Leung, P.L.

    2001-01-01

    In order to improve accuracy of TL authentication test for porcelain, a method of measurement of annual dose using ultrathin (CaSO 4 :Tm) dosage layer on porcelain was studied. The TLD was placed on the part of porcelain without glaze. A comparison of measurement of annual dose for surface TLD, inside TLD and alpha counting on porcelain was made. The results show that this technique is suitable for measuring annual dose and improving accuracy of TL authentication test for both porcelain and pottery

  3. Thermoluminescent dosemeters of CaSO4: Dy + Teflon

    International Nuclear Information System (INIS)

    Campos, L.L.

    1989-01-01

    The development of a pellet dosemeter of CaSO 4 : Dy + Teflon at the Dosimetric Materials Production Laboratory - IPEN/Brazilian CNEN-SP is presented. The pellets were produced by cold pressing and sintering a mixture of CaSO 4 : Dy and Teflon powders. The pellet characteristics from the point of view of dosimetry. A filter combination providing an energy independent response from 20 KeV to 1,25 MeV was obtained. The dosemeter consists of three pellets sealed between two thin plastic sheets and placed under plastic and lead filters. The combination of these three filters allows to determine the energy of an unknown source. (author) [pt

  4. Neutron dosemeter responses in workplace fields and the implications of using realistic neutron calibration fields

    International Nuclear Information System (INIS)

    Thomas, D.J.; Horwood, N.; Taylor, G.C.

    1999-01-01

    The use of realistic neutron calibration fields to overcome some of the problems associated with the response functions of presently available dosemeters, both area survey instruments and personal dosemeters, has been investigated. Realistic calibration fields have spectra which, compared to conventional radionuclide source based calibration fields, more closely match those of the workplace fields in which dosemeters are used. Monte Carlo simulations were performed to identify laboratory systems which would produce appropriate workplace-like calibration fields. A detailed analysis was then undertaken of the predicted under- and over-responses of dosemeters in a wide selection of measured workplace field spectra assuming calibration in a selection of calibration fields. These included both conventional radionuclide source calibration fields, and also several proposed realistic calibration fields. The present state of the art for dosemeter performance, and the possibilities of improving accuracy by using realistic calibration fields are both presented. (author)

  5. A personal dosemeter of radon daughter products

    International Nuclear Information System (INIS)

    Burian, I.; Richter, M.; Ochec, J.; Dohnal, J.

    1990-01-01

    The OD 88 personal dosemeter for radon daughter products uses an alpha particle track detector and is of active type, with forced air aspiration through the detecting system. The pumping device consists of a miniature membrane pump and an electronic speed controller. The air flow rate is little affected by normal changes in supply voltage and/or pneumatic resistance of the pump circuit. The dosemeter is embedded in a miner's lamp and is fed from its accumulator battery. The pumping device is activated as the lamp is taken out of the charger and deactivated as it is slid into the charger again. The dosemeter head accommodates an AFPC filter on which the radon daughter products deposit. The energy of the alpha particles is reduced by an air layer and a Makrofol decelerating foil. The particles hitting the detector give rise to defects with an intensity proportional to the total linear stopping power at the moment of incidence; ideal tracks 10 μm in size require incident energy of 1.1 to 1.3 MeV. The detector is replaced in a month and worked up in an etching vessel, making use of the higher solubility of the detecting layer of the foil in NaOH at the spot of the alpha particle incidence. (P.A.). 4 figs., 17 refs

  6. TLD array for precise dose measurements in stereotactic radiation techniques

    International Nuclear Information System (INIS)

    Ertl, A.; Kitz, K.; Griffitt, W.; Hartl, R.F.E.; Zehetmayer, M.

    1996-01-01

    We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. This TLD array may be useful for phantom or tissue model studies on the spatial dose distribution in confined radiation targets as used in stereotactic radiotherapy. (author)

  7. Mejora de la eficiencia energética en una vivienda

    OpenAIRE

    Díaz Oliva, Marc

    2013-01-01

    El objetivo de este proyecto es la mejora de la eficiencia energética de la vivienda este objetivo me viene por una estancia en Alemania donde todas las viviendas están concebidas para obtener la máxima eficiencia y por consiguiente ahorro una de las cosas que más me llamo la atención fue la implantación de energías renovables ya que las horas de luz son menores a las obtenidas en España por este motivo quise comprobar cuanto se podía mejorar la eficiencia en mi vivienda y s...

  8. SU-E-T-594: Out-Of-Field Neutron and Gamma Dose Estimated Using TLD-600/700 Pairs in the Wobbling Proton Therapy System

    International Nuclear Information System (INIS)

    Chen, Y; Lin, Y; Chen, H; Tsai, H

    2015-01-01

    Purpose: Secondary fast neutrons and gamma rays are mainly produced due to the interaction of the primary proton beam with the beam delivery nozzle. These secondary radiation dose to patients and radiation workers are unwanted. The purpose of this study is to estimate the neutron and gamma dose equivalent out of the treatment volume during the wobbling proton therapy system. Methods: Two types of thermoluminescent (TL) dosimeters, TLD-600 ( 6 LiF: Mg, Ti) and TLD-700 ( 7 LiF: Mg, Ti) were used in this study. They were calibrated in the standard neutron and gamma sources at National Standards Laboratory. Annealing procedure is 400°C for 1 hour, 100°C for 2 hours and spontaneously cooling down to the room temperature in a programmable oven. Two-peak method (a kind of glow curve analysis technique) was used to evaluate the TL response corresponding to the neutron and gamma dose. The TLD pairs were placed outside the treatment field at the neutron-gamma mixed field with 190-MeV proton beam produced by the wobbling system through the polyethylene plate phantom. The results of TLD measurement were compared to the Monte Carlo simulation. Results: The initial experiment results of calculated dose equivalents are 0.63, 0.38, 0.21 and 0.13 mSv per Gy outside the field at the distance of 50, 100, 150 and 200 cm. Conclusion: The TLD-600 and TLD-700 pairs are convenient to estimate neutron and gamma dosimetry during proton therapy. However, an accurate and suitable glow curve analysis technique is necessary. During the wobbling system proton therapy, our results showed that the neutron and gamma doses outside the treatment field are noticeable. This study was supported by the grants from the Chang Gung Memorial Hospital (CMRPD1C0682)

  9. SU-E-T-594: Out-Of-Field Neutron and Gamma Dose Estimated Using TLD-600/700 Pairs in the Wobbling Proton Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y [College of Medicine, Chang Gung University, Linkou, Taoyuan, Taiwan (China); Lin, Y [College of Medicine, Chang Gung University, Linkou, Taoyuan, Taiwan (China); Medical Physics Research Center, Institute for Radiological Research, Chang Gung University / Chang Gung Memorial Hospital, Linkou, Taoyuan, Taiwan (China); Chen, H [College of Medicine, Chang Gung University, Linkou, Taoyuan, Taiwan (China); Chang Gung Memorial Hospital, Linkou, Taoyuan, Taiwan (China); Tsai, H [College of Medicine, Chang Gung University, Linkou, Taoyuan, Taiwan (China); Medical Physics Research Center, Institute for Radiological Research, Chang Gung University / Chang Gung Memorial Hospital, Linkou, Taoyuan, Taiwan (China); Healthy Aging Research Center, Chang Gung University, Linkou, Taoyuan, Taiwan (China)

    2015-06-15

    Purpose: Secondary fast neutrons and gamma rays are mainly produced due to the interaction of the primary proton beam with the beam delivery nozzle. These secondary radiation dose to patients and radiation workers are unwanted. The purpose of this study is to estimate the neutron and gamma dose equivalent out of the treatment volume during the wobbling proton therapy system. Methods: Two types of thermoluminescent (TL) dosimeters, TLD-600 ({sup 6}LiF: Mg, Ti) and TLD-700 ({sup 7}LiF: Mg, Ti) were used in this study. They were calibrated in the standard neutron and gamma sources at National Standards Laboratory. Annealing procedure is 400°C for 1 hour, 100°C for 2 hours and spontaneously cooling down to the room temperature in a programmable oven. Two-peak method (a kind of glow curve analysis technique) was used to evaluate the TL response corresponding to the neutron and gamma dose. The TLD pairs were placed outside the treatment field at the neutron-gamma mixed field with 190-MeV proton beam produced by the wobbling system through the polyethylene plate phantom. The results of TLD measurement were compared to the Monte Carlo simulation. Results: The initial experiment results of calculated dose equivalents are 0.63, 0.38, 0.21 and 0.13 mSv per Gy outside the field at the distance of 50, 100, 150 and 200 cm. Conclusion: The TLD-600 and TLD-700 pairs are convenient to estimate neutron and gamma dosimetry during proton therapy. However, an accurate and suitable glow curve analysis technique is necessary. During the wobbling system proton therapy, our results showed that the neutron and gamma doses outside the treatment field are noticeable. This study was supported by the grants from the Chang Gung Memorial Hospital (CMRPD1C0682)

  10. HOW DO HOSPITAL STERILISATION PROCEDURES AFFECT THE RESPONSE OF PERSONAL EXTREMITY RINGS AND OF EYE LENS TL DOSEMETERS?

    Science.gov (United States)

    Kopeć, Renata; Bubak, Anna; Budzanowski, Maciej; Sas-Bieniarz, Anna; Szumska, Agnieszka

    2016-09-01

    Stringent standards of hygiene must be applied in medical institutions, especially at operating blocks or during interventional radiology procedures. Medical equipment, including personal dosemeters that have to be worn by medical staff during such procedures, needs therefore to be sterilised. In this study, the effect of various sterilisation procedures has been tested on the dose response of extremity rings and of eye lens dosemeters in which thermoluminescent (TL) detectors (of types MTS-N and MCP-N, respectively) are used. The effects of medical sterilisation procedures were studied: by chemicals, by steam or by ultraviolet (UV), on the dose assessment by extremity rings and by eye lens dosemeters. Since it often happens that a dosemeter is accidentally machine-washed together with protective clothing, the effect of laundering on dose assessment by these dosemeters was also tested. The sterilisation by chemicals is mostly safe for TL detectors assuming that the dosemeters are waterproofed. Following sterilisation by water vapour, the response of these dosemeters diminished by some 30 %, irrespectively of the period of sterilisation; therefore, this method is not recommended. UV sterilisation can be applied to EYE-D™ eye lens dosemeters if their encapsulation is in black. The accidental dosemeter laundry in a washing machine has no impact on measured dose. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Analysis of personnel monitoring control card data

    International Nuclear Information System (INIS)

    Ande, C.D.; Sneha, C.; Madhumita, B.; Bakshi, A.K.; Datta, D.

    2018-01-01

    In India, personnel monitoring of radiation workers for X-, beta- and gamma- radiation is carried out using a thermoluminescence dosemeter (TLD) system based on CaSO 4 :Dy Teflon TLD disc. A large number of radiation workers get very low occupational doses and their doses are reported as zero since it is not above detectable limits. Therefore, the detection of low levels of occupational dose over and above the natural background assumes great importance. In the present system, the estimation of the background dose is achieved by use of control dosemeters. An analysis of the readings of the control dosimeters sent to various institutions was carried out to arrive at conclusions regarding the validity of the use of control dosimeter

  12. Optimal selection of TLD chips

    International Nuclear Information System (INIS)

    Phung, P.; Nicoll, J.J.; Edmonds, P.; Paris, M.; Thompson, C.

    1996-01-01

    Large sets of TLD chips are often used to measure beam dose characteristics in radiotherapy. A sorting method is presented to allow optimal selection of chips from a chosen set. This method considers the variation

  13. Micro-dosemeter instrument (MIDN) for assessing risk in space

    International Nuclear Information System (INIS)

    Pisacane, V. L.; Dolecek, Q. E.; Malak, H.; Cucinotta, F. A.; Zaider, M.; Rosenfeld, A. B.; Rusek, A.; Sivertz, M.; Dicello, J. F.

    2011-01-01

    Radiation in space generally produces higher dose rates than that on the Earth's surface, and contributions from primary galactic and solar events increase with altitude within the magnetosphere. Presently, no personnel monitor is available to astronauts for real-time monitoring of dose, radiation quality and regulatory risk. This group is developing a prototypic instrument for use in an unknown, time-varying radiation field. This micro-dosemeter-dosemeter nucleon instrument is for use in a space-suit, spacecraft, remote rover and other applications. It provides absorbed dose, dose rate and dose equivalent in real time so that action can be taken to reduce exposure. Such a system has applications in health physics, anti-terrorism and radiation-hardening of electronics as well. The space system is described and results of ground-based studies are presented and compared with predictions of transport codes. An early prototype in 2007 was successfully launched, the only solid-state micro-dosemeter to have flown in space. Published by Oxford Univ. Press on behalf of the US Government 2011. (authors)

  14. Operational trials of single- and multi-element CR-39 dosemeters for the DIDO and PLUTO reactors at the Harwell Laboratory

    International Nuclear Information System (INIS)

    Gallacher, G.G.; Perks, C.A.

    1993-01-01

    Single- and multi-element CR-39 dosemeters, developed at the Harwell Laboratory, and a commercially available multi-element CR-39 dosemeter (obtained from Track Analysis Systems Ltd), were evaluated for their potential as neutron dosemeters for personnel working at Harwell Laboratory's research reactors. Owing to the angular dependence of the CR-39 (processed using electrochemical etching), the single-element dosemeter was found to be impractical. Consequently, a multi-element dosemeter was developed, which consisted of a cube of side 36 mm with CR-39 elements (also processed using electrochemical etching) attached to each of the sides. Although this dosemeter was technically suitable for this type of dosimetry, it was considered to be unacceptably bulky in personnel trials. The commercially available CR-39 dosemeter tested was much smaller (the CR-39 was only chemically etched) and this was considered to be acceptable as a personnel dosemeter. In addition, trials with personnel working at active handling glove boxes indicated that single-element dosemeters might be adequate, but further work would be needed to verify this. (author)

  15. Characteristic of the dosemeter used by the service of film dosimetry in the CPHR

    International Nuclear Information System (INIS)

    Capote Ferrera, E.A.; Diaz Bernal, E.; Manzano de Armas, J.F.

    1998-01-01

    Characteristic of the dosemeter used by the service of dosimetria filmica of the CPHR.The use of film dosemeter brings I get the aquisition first it gives data that it includes its evaluation regarding the calibration magnitude and second the interpretation of these data in terms of the magnitude of personal dose, such as the equivalent dose (ICRU 47) or to the effective dose (ICRP 60). presently work the results of the study of the characteristics of the dosemeters are picked up

  16. On the importance of the 2nd readout as a function of dose

    International Nuclear Information System (INIS)

    Batel, V.I.; Alves, J.G.; Rangel, S.; Abrantes, J.N.

    2005-01-01

    Full text: The individual monitoring service at ITN-DPRSN is based on a TLD dosimetry system. The system is comprised of two 6600 Harshaw readers and on the Harshaw 8814 TL card and holder containing two LiF:Mg,Ti (TLD-100) detectors for the evaluation of H p (10) and H p (0.07). As part of our normal reading procedure, after the readout for dose evaluation a second reading is always carried out before the dosemeters are considered ready for another use and shipped to clients. Second readouts produce the residual signal and confirm the dosemeter is reset. However, it is a time-consuming task and particularly in the low dose cases, the question arises whether it could be avoided? In this paper the importance of a second readout was evaluated and is presented. Four experiments were performed using two groups of twenty-five randomly selected dosemeters. In each group the dosemeters were organized in sets of five and each set was irradiated to a different dose of 0.5, 1, 5, 10 and 50 mSv and processed. This was repeated for ten times. In the first experiment the dosemeters were read for dose evaluation and a second readout was always performed. In the second experiment the second readout was suppressed. The third and fourth experiments were as the first and second, but the dosemeters were irradiated to an additional dose of 0.50 mSv in between. The results obtained from experiments one and two, evaluate the importance of the second readout on the reproducibility of the measurement as a function of dose. Experiments three and four also provide information on the capacity to detect an intermediate low dose of 0.5 mSv, as a function of dose, for the normal reading procedure and when the second readout is avoided. In this paper the importance of the second readout is studied performing reproducibility measurements as a function of dose and by testing the capacity to detect the 0.5 mSv intermediate dose also as a function of dose. (author)

  17. Energy dependence of pMOS dosemeters

    International Nuclear Information System (INIS)

    Savic, Z.; Stankovic, S.; Kovacevic, M.; Petrovic, M.

    1996-01-01

    The results are presented of experimental work and numerical simulations of the energy response for pMOS dosimetric transistors in their custom packages. Specially produced radiation soft pMOS transistors were used in this experimental work. The irradiation of pMOS dosemeters was done using 60 Co and 137 Cs sources, a dosimetric X ray unit, and a radiotherapeutic linear accelerator in the range of photon energies from 21 keV to 8 MeV. The results show that package geometry and materials can significantly affect and smooth the energy dependence of pMOS transistors and that in custom transistor packages they are not tissue-equivalent dosemeters. Their response in the photon energy range of 45 to 250 keV is significantly larger than it should be (maximum dose enhancement factor can be as high as 8) and some energy compensation techniques must be used in order to fulfill the requirements of corresponding standards. (Author)

  18. Energy dependence of pMOS dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Savic, Z. [Military Technical Institute, Belgrade (Yugoslavia); Stankovic, S.; Kovacevic, M.; Petrovic, M. [Institute of Nuclear Sciences, Belgrade (Yugoslavia). Radiation Protection Dept.

    1996-10-01

    The results are presented of experimental work and numerical simulations of the energy response for pMOS dosimetric transistors in their custom packages. Specially produced radiation soft pMOS transistors were used in this experimental work. The irradiation of pMOS dosemeters was done using {sup 60}Co and {sup 137}Cs sources, a dosimetric X ray unit, and a radiotherapeutic linear accelerator in the range of photon energies from 21 keV to 8 MeV. The results show that package geometry and materials can significantly affect and smooth the energy dependence of pMOS transistors and that in custom transistor packages they are not tissue-equivalent dosemeters. Their response in the photon energy range of 45 to 250 keV is significantly larger than it should be (maximum dose enhancement factor can be as high as 8) and some energy compensation techniques must be used in order to fulfill the requirements of corresponding standards. (Author).

  19. Ten years experience with a large computerized TLD-personnel monitoring system

    International Nuclear Information System (INIS)

    Duftschmid, K.E.

    1986-01-01

    It is now ten years since our Institute for Radiation Protection has fully replaced its filmdosimetry service by a computerized automated TLD system. Presently more than 13000 radiation workers are monthly monitored by three automated TLD readers linked to the computer center. The paper describes system hardware and software and experience gained in long-term routine operation. In particular the introduction of the new ICRU quantities for personnel dosimetry in the existing TLD system is discussed. (Author)

  20. Experimental determination of relative light conversion factors of TLD-100 for protons with energies from 2.0 to 9.0 MeV

    International Nuclear Information System (INIS)

    Schmidt, P.; Fellinger, J.; Huebner, K.; Henniger, J.

    1985-01-01

    Relative light conversion factors (RLCF) for heavy charged particles (protons, deuterons, recoils) are needed for the calculation of the neutron sensitivity of thermoluminescent (TL) detectors. Such light conversion factors can be determined experimentally. A method is represented for the experimental determination of RLCF. The described experimental facility gives the possibility of irradiation of different luminophor samples with heavy charged particles and flux determination and particle spectrometry at the same time. For the determination of RLCF the doses are needed which are applicated at the irradiation with heavy charged particles and gamma radiation, respectively, and the according detector readings at the TL evaluation. The problems arising at the dose determination are discussed. With this experimental facility the RLCF for TLD-100 for protons were determined. The relative light conversion factors determined according to the light sum method as well as the peak height method are summarizinhly represented and discussed. Furthermore a comparison of the glow curves is made after gamma and proton irradiation

  1. Positional glow curve simulation for thermoluminescent detector (TLD) system design

    International Nuclear Information System (INIS)

    Branch, C.J.; Kearfott, K.J.

    1999-01-01

    Multi- and thin element dosimeters, variable heating rate schemes, and glow-curve analysis have been employed to improve environmental and personnel dosimetry using thermoluminescent detectors (TLDs). Detailed analysis of the effects of errors and optimization of techniques would be highly desirable. However, an understanding of the relationship between TL light production, light attenuation, and precise heating schemes is made difficult because of experimental challenges involved in measuring positional TL light production and temperature variations as a function of time. This work reports the development of a general-purpose computer code, thermoluminescent detector simulator, TLD-SIM, to simulate the heating of any TLD type using a variety of conventional and experimental heating methods including pulsed focused or unfocused lasers with Gaussian or uniform cross sections, planchet, hot gas, hot finger, optical, infrared, or electrical heating. TLD-SIM has been used to study the impact on the TL light production of varying the input parameters which include: detector composition, heat capacity, heat conductivity, physical size, and density; trapped electron density, the frequency factor of oscillation of electrons in the traps, and trap-conduction band potential energy difference; heating scheme source terms and heat transfer boundary conditions; and TL light scatter and attenuation coefficients. Temperature profiles and glow curves as a function of position time, as well as the corresponding temporally and/or spatially integrated glow values, may be plotted while varying any of the input parameters. Examples illustrating TLD system functions, including glow curve variability, will be presented. The flexible capabilities of TLD-SIM promises to enable improved TLD system design

  2. Characterization of TLD-100 in powders for dosimetric quality control of 192 Ir sources used in brachytherapy of high dose rate

    International Nuclear Information System (INIS)

    Loaiza C, S.P.

    2007-01-01

    The Secondary Standard Dosimetric at the National Institute of Nuclear Research (ININ) calibrated a lot of powdered TLD-100 (LiF:Mg,Ti) in terms of absorbed dose to water D w for the energy of: 60 Co, 137C s, X rays of 250 and 50 kVp. Later on, it is carried out an interpolation of the calibration for the energy of the 192 Ir. This calibration is part of a dosimetric quality control program, to solve the problems of traceability for the measurements carried out by the users of 192 Ir sources employed in the treatments of High Dose Rate Brachytherapy (HDR) at the Mexican Republic. The calibrations of the radiation beams are made with the following protocols: IAEA TRS-398 for the 60 Co for D w , using a secondary standard ionization chamber PTW N30013 calibrated in D w by the National Research Council (NRC, Canada). AAPM TG-43 for D w in terms of the strength kerma Sk, calibrating this last one quantity for the 137 Cs radioactive source, with a well chamber HDR 1000 PLUS traceable to the University of Wisconsin (US). AAPM TG-61 for X ray of 250 and 50 kVp for D w start to Ka using field standard a Farmer chamber PTW 30001 traceable to K for the Central Laboratory of Electric Industries (CLEI, France). The calibration curves (CC) they built for the response of the powder TLD: R TLD vs D w : For the energy of 60 Co, 137 Cs, X rays of 250 and 50 kVp. Fitting them with the least square method weighed by means of a polynomial of second grade that corrects the supra linearity of the response. iii. Each one of the curves was validated with a test by lack of fitting and for the Anderson Darling normality test, using the software MINITAB in both cases. iv. The sensibility factor (F s ) for each energy corresponds to the slope of the CC, v. The F s for the two 192 Ir sources used are interpolated: one for a Micro Selectron source and the other one a Vari Source source. Finally, a couple of capsules were sent to two hospitals that have the HDR Brachytherapy with sources of 192

  3. Introducing 2D barcode on TLD cards - a step towards automation in personnel monitoring

    International Nuclear Information System (INIS)

    Ajoy, K.C.; Dhanasekaran, A.; Annalakshmi, O; Rajagopal, V.; Santhanam, R.; Jose, M.T.

    2018-01-01

    As part of personnel monitoring services, TLD lab, RSD, IGCAR issues and receives large numbers of TLD cards every month, for use by occupational workers belonging to various hot facilities at Kalpakkam. Considering the nature of the work being manual, routine, labour intensive and being prone for human errors, introducing automation would be necessary at the TLD lab as well as at the user facility. This requires identification of the individual components of the TLD and embed them with unique identification for the system to accomplish the task. The paper discusses the automation part related to the TLD cards

  4. Thermoluminescent Signals Caused by Disturbing Effects

    International Nuclear Information System (INIS)

    German, U.; Weinstein, M.; Ben-Shachar, B.

    1999-01-01

    One of the major sources of uncertainty in the measurement of low radiation doses by means of thermoluminescence dosemeters is the presence of disturbing thermoluminescence signals, especially luminescence caused by visible light, and by materials attached to the heated areas. Glow curves of thermoluminescence dosemeters contain useful information that can improve the accuracy and the reliability of the thermoluminescent measurements. The influence of the various disturbing effects can be recognised in the shape of the glow curves and can sometimes be separated from the exposure. Some examples are presented of signals arising from the two disturbing effects mentioned above, the signal contributed by Teflon used in the TLD-100 cards of Bicron/Harshaw and some abnormal glow curves due to dirt attached to the cards. Subtraction of the contributions due to these effects is suggested to obtain the net exposure signal. (author)

  5. Next Generation Model 8800 Automatic TLD Reader

    International Nuclear Information System (INIS)

    Velbeck, K.J.; Streetz, K.L.; Rotunda, J.E.

    1999-01-01

    BICRON NE has developed an advanced version of the Model 8800 Automatic TLD Reader. Improvements in the reader include a Windows NT TM -based operating system and a Pentium microprocessor for the host controller, a servo-controlled transport, a VGA display, mouse control, and modular assembly. This high capacity reader will automatically read fourteen hundred TLD Cards in one loading. Up to four elements in a card can be heated without mechanical contact, using hot nitrogen gas. Improvements in performance include an increased throughput rate and more precise card positioning. Operation is simplified through easy-to-read Windows-type screens. Glow curves are displayed graphically along with light intensity, temperature, and channel scaling. Maintenance and diagnostic aids are included for easier troubleshooting. A click of a mouse will command actions that are displayed in easy-to-understand English words. Available options include an internal 90 Sr irradiator, automatic TLD calibration, and two different extremity monitoring modes. Results from testing include reproducibility, reader stability, linearity, detection threshold, residue, primary power supply voltage and frequency, transient voltage, drop testing, and light leakage. (author)

  6. How to diagnose any type of TLD Reader?

    International Nuclear Information System (INIS)

    Rodriguez, Manuel Lopez; Garcia, Jose A. Tamayo; Gil, Alex Vergara; Lores, Stefan Gutierrez; Acosta, Andry Romero; Villanueva, Gilberto Alonso

    2013-01-01

    The acquisition of know how of practical experiences obtained in the repair and maintenance of readers TLD RADOS for five years of work and the request by the International Atomic Energy for signing new Research Contracts (CRP), made possible the CRP 13328, in which the specialist is committed in the course of a year, to deliver educational software in order to train personnel associated with the operation of the TLD readers RADOS. Due to the importance of continuous transfer of knowledge for new generations of technicians and specialists who join our laboratories, the idea came when the first interactive CD that grouped 19 videos, divided into three blocks was ready: learning, repair and maintenance; it was suggested to expand the training for any TLD reader. Thus a much more complete than the first version package emerged. 7 cases were subsequently published in an IAEA TECDOC, 1599 were included

  7. Minimizing TLD-DRD differences

    International Nuclear Information System (INIS)

    Riley, D.L.; McCoy, R.A.; Connell, W.D.

    1987-01-01

    When substantial differences exist in exposures recorded by TLD's and DRD's, it is often necessary to perform an exposure investigation to reconcile the difference. In working with several operating plants, the authors have observed a number of causes for these differences. This paper outlines these observations and discusses procedures that can be used to minimize them

  8. Feasibility study of extremity dosemeter based on polyallyl-diglycol-carbonate (CR-39) for neutron exposure

    International Nuclear Information System (INIS)

    Chau, Q.; Bruguier, P.

    2007-01-01

    In nuclear facilities, some activities such as reprocessing, recycling and production of bare fuel rods expose the workers to mixed neutron-photon fields. For several workplaces, particularly in glove boxes, some workers expose their hands to mixed fields. The mastery of the photon extremity dosimetry is relatively good, whereas the neutron dosimetry still raises difficulties. In this context, the Inst. for Radiological Protection and Nuclear Safety (IRSN) has proposed a study on a passive neutron extremity dosemeter based on chemically etched CR-39 (PADC: polyallyl-diglycol-carbonate), named PN-3, already used in routine practice for whole body dosimetry. This dosemeter is a chip of plastic sensitive to recoil protons. The chemical etching process amplifies the size of the impact. The reading system for tracks counting is composed of a microscope, a video camera and an image analyser. This system is combined with the dose evaluation algorithm. The performance of the dosemeter PN-3 has been largely studied and proved by several laboratories in terms of passive individual neutron dosemeter which is used in routine production by different companies. This study focuses on the sensitivity of the extremity dosemeter, as well as its performance in the function of the level of the neutron energy. The dosemeter was exposed to monoenergetic neutron fields in laboratory conditions and to mixed fields in glove boxes at workplaces. (authors)

  9. La eficiencia terminal en la Educación Superior

    Directory of Open Access Journals (Sweden)

    Dr. C. Victor Millo Carmenate

    2016-04-01

    Full Text Available Se procesan los resultados de promoción de los estudian­tes de la carrera de Ingeniería Mecánica disponibles en la Secretaría General de la Facultad de Ingeniería de la Universidad de Cienfuegos entre los años 2008 al 2015 y se encuestan 35 de los 75 que abandonaron sus estudios de­finitivamente en este mismo período, con el objetivo de co­nocer desde la perspectivas de los estudiantes causas del comportamiento de varios indicadores de eficiencia e iden­tificar los factores que afectan la eficiencia terminal, para lo cual se hizo uso de métodos estadísticos y cualitativos de análisis. Se realiza una propuesta de acciones a considerar para la mejora de los indicadores de eficiencia terminal.

  10. Eurados trial performance test for personal dosemeters for external beta radiation

    DEFF Research Database (Denmark)

    Christensen, P.; Bordy, J.M.; Ambrosi, P.

    2001-01-01

    On the initiative of the European Dosimetry Group (EURADOS) action group 'Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation' a trial performance test for whole-body and extremity personal dosemeters broadly representative of those in use in the EU...... the results obtained from the exercise. In particular, based on the replies to a questionnaire issued to each participant, the results are analysed in relation to important design characteristics of the dosemeters taking part in the test....

  11. Perspectivas sobre la eficiencia del sistema portuario español

    Directory of Open Access Journals (Sweden)

    Medal Bartual, A.

    2011-01-01

    Full Text Available La Ley 33/2010, de 5 de agosto, señala explícitamente “la exigencia de adoptar en España medidas que mejoren la gestión de nuestros puertos y su eficiencia, impulsando su competitividad en una coyuntura de fuerte competencia internacional”. Con este objeto, el presente artículo analiza las perspectivas futuras sobre la eficiencia de los puertos que integran el actual Sistema Portuario Español, tanto a corto como a medio plazo. Con ello pretendemos dar respuesta a cuestiones cómo qué nivel de eficiencia van a tener los puertos españoles en el futuro, qué puertos van a liderar el panorama portuario español en los próximos años, o cuál será el ranking jerárquico de dichas entidades en función de su nivel de eficiencia. Las respuestas a las mismas permitirán a los gestores portuarios tomar las medidas oportunas para mejorar la gestión de los puertos en la línea propuesta por la citada Ley. Para el análisis de la eficiencia previsible del Sistema Portuario Español hemos aplicado la metodología DEA con tolerancias, partiendo de las previsiones realizadas por el Organismo Público Puertos del Estado y recogidas en el Plan Estratégico de Infraestructuras y Transportes del 2009.

  12. Characterization of TLD-100 in powders for dosimetric quality control of {sup 192} Ir sources used in brachytherapy of high dose rate; Caracterizacion de TLD-100 en polvo para control de calidad dosimetrico de fuentes de Ir{sup 192} usadas en braquiterapia de alta tasa de dosis

    Energy Technology Data Exchange (ETDEWEB)

    Loaiza C, S.P

    2007-07-01

    The Secondary Standard Dosimetric at the National Institute of Nuclear Research (ININ) calibrated a lot of powdered TLD-100 (LiF:Mg,Ti) in terms of absorbed dose to water D{sub w} for the energy of: {sup 60}Co, {sup 137C}s, X rays of 250 and 50 kVp. Later on, it is carried out an interpolation of the calibration for the energy of the {sup 192}Ir. This calibration is part of a dosimetric quality control program, to solve the problems of traceability for the measurements carried out by the users of {sup 192}Ir sources employed in the treatments of High Dose Rate Brachytherapy (HDR) at the Mexican Republic. The calibrations of the radiation beams are made with the following protocols: IAEA TRS-398 for the {sup 60}Co for D{sub w}, using a secondary standard ionization chamber PTW N30013 calibrated in D{sub w} by the National Research Council (NRC, Canada). AAPM TG-43 for D{sub w} in terms of the strength kerma Sk, calibrating this last one quantity for the {sup 137}Cs radioactive source, with a well chamber HDR 1000 PLUS traceable to the University of Wisconsin (US). AAPM TG-61 for X ray of 250 and 50 kVp for D{sub w} start to Ka using field standard a Farmer chamber PTW 30001 traceable to K for the Central Laboratory of Electric Industries (CLEI, France). The calibration curves (CC) they built for the response of the powder TLD: R{sub TLD} vs D{sub w}: For the energy of {sup 60}Co, {sup 137}Cs, X rays of 250 and 50 kVp. Fitting them with the least square method weighed by means of a polynomial of second grade that corrects the supra linearity of the response. iii. Each one of the curves was validated with a test by lack of fitting and for the Anderson Darling normality test, using the software MINITAB in both cases. iv. The sensibility factor (F{sub s}) for each energy corresponds to the slope of the CC, v. The F{sub s} for the two {sup 192}Ir sources used are interpolated: one for a Micro Selectron source and the other one a Vari Source source. Finally, a couple of

  13. Preparation of the FXG gel dosemeter and studying its response for low and medium energy X-rays

    International Nuclear Information System (INIS)

    Bero, M.; Kharita, M. H.

    2008-02-01

    Gel dosimetry method was found to be capable of addressing complicated issues related to dose measurements particularly in modern sophisticated radiotherapy applications. Ferrous-sulphate Xylenol-orange and Gelatin (FXG) radiochromic gel dosemeter is one of the systems used for such applications. Some chemical dosemeters show different response for low and medium energies X-rays in comparison with high energy-photons. The energy and dose rate dependence of the FXG dose response was examined. In addition to the detector response other important dosimetric properties of the system were investigated for different X-ray beam qualities with tube voltages in the range 100 - 300 kv. An orthovoltage X-ray therapy unit was used to irradiate standard sized samples of FXG from different batches for radiation doses in the range 0 - 8 Gy. This work includes in the first stage the preparation of the radiochromic gel dosemeter (FXG) as well as its calibration in gamma radiation field. Furthermore, the stability and reproducibility of measurements were tested. The obtained results were found to be suitable as a basis to carry on the next stage of this study. The second phase was centred about the delivery of radiation doses from X-ray source that has increasing energy and evaluating the gel material properties as a dosemeter in this case, with concentration on finding the changes of the gel material response with the changes in the applied X-ray energy. Therefore establishing the response radiation energy dependence and comparing the measurement results with other results taken from other known dosimetry system such as ion chambers. Experiments shows that the FXG gel detector has a dynamic rage suitable for the dose delivered in radiotherapy treatment; its response as a function of the dose rate is also stable in the range of radiation energies applied.(Author)

  14. CaSO4: Dy + Teflon thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Campos, L.L.

    1986-01-01

    A pellet dosemeter of CaSO 4 : Dy + Teflon was developed at IPEN. CaSO 4 : Dy thermoluminescent phosphor, grown in the Dosimetric Materials Production Laboratory was chosen, due to its high sensitivity, ease of preparation and comparatively low cost. Pellets were produced by cold pressing and sintering a mixture of CaSO 4 : Dy and Teflon powders. Extensive work was done to study in detail all CaSO 4 : Dy pellets characteristics from the point of view of dosimetry with the purpose of introducing it in the routine use. A filter combination providing an energy independent response from 20 KeV to 1,25 MeV was obtained. The dosemeter consists of three pellets sealed between two thin plastic sheets and placed under plastic and lead filters. The combination of these tree filters allows the exposure as well as the energy determination of an unknown source. (Author) [pt

  15. Fourth intercomparison of personal dosemeters used in US Department of Energy accelerator facilities

    CERN Document Server

    Stewart, R D; Otto, T; Loesch, R M

    2000-01-01

    Personal neutron dosemeters from seven US Department of Energy (DOE) laboratories were mailed to the European Laboratory for Particle Physics (CERN) and irradiated using the well-characterised CERN reference radiation facility (CERF). Neutron dose equivalents determined using the DOE personal dosemeters have been compared to the reference dose equivalent as determined using a tissue-equivalent proportional counter (TEPC). In the 0.5 to 5 mSv dose equivalent range, the comparison of results suggests that the neutron personal dosemeters in use at DOE facilities are capable of estimating dose equivalents for high energy neutrons to within a factor of at least 2 or 3. If a field-specific calibration factor is used to correct the dose equivalent responses, the agreement with the reference dose equivalent for these dosemeters can be improved to better than about 25 to 65at is decoupled from the core in /sup 183,185/Au, becomes the 3/2[532] state (h9/2 parentage) strongly coupled in the doubly-odd /sup 184/Au nucleu...

  16. Analysis of dose distribution in interventionist radiology professionals

    International Nuclear Information System (INIS)

    Mauricio, Claudia L.P.; Silva, Leonardo Peres; Canevaro, Lucia V.; Luz, Eara de Souza

    2005-01-01

    In this work, an evaluation was made of the distribution of dose received by professionals involved in some procedures of Interventional Radiology at hospitals and clinics in Rio de Janeiro, RJ, Brazil. For these measurements thermoluminescent dosemeters (TLD) of LiF: Mg, Ti (TLD100) were used, positioned at different points of the body of professionals: the hands, knees, neck, forehead and chest, inside and outside the lead apron. The measurements were made by procedure and/or a day of work, and the TLD were calibrated in equivalent operating magnitude of personal dose (Hp (d)) at different depths: 0.07 mm, 3 mm and 10 mm. In some procedures, physicians (holders of service and residents) received significant doses. The results show the importance of the appropriate training of these professionals and the use of personal protective equipment (PPE), such as thyroid shield, which is not always used. Based on these evaluations, some suggestions were made in order to optimize the dose values in these procedures and a discussion on the need for additional monitoring points

  17. TLD territorial network in the Czech Republic

    Energy Technology Data Exchange (ETDEWEB)

    Kroutilikova, D. [National Radiation Protection Institute, Prague (Czech Republic)

    1996-12-31

    At present, there are 236 measuring points practically homogeneously distributed on the territory of the Czech Republic. 98 measuring points are distributed as local TLD-networks in the surroundings of Czech two nuclear power plants. Both of the TLD-networks are operated by the National Radiation Protection Institute in Prague. The dosimeters hitherto used are the CaSO{sub 4}:Dy-teflon detectors placed in TL-badges and shielded on both sides by energy compensation filters composed of lead and tin. Recently, a new modernization of the measuring system, type of dosimeter and methods of evaluation is under way. From 1996 the Czech Radiation Monitoring Network will be used the TLD system HARSHAW 4000, along with the type 8807 ENVIRONMENTAL DOSIMETER. The dosimeter is composed of four TL-elements - two LiF and two CaF{sub 2}, placed in a plastic badge. In addition, the CaF{sub 2} elements are shielded on both sides by energy compensation filters composed of tantalum and lead. Before the routine use of the new system a testing of the dosimeters was made. The following text summarizes the obtained results (J.K.). 4 tabs.

  18. Performance evaluation of vertical feed fully automated TLD badge reader using 0.8 and 0.4 mm teflon embedded CaSO4:Dy dosimeters

    International Nuclear Information System (INIS)

    Ratna, P.; More, Vinay; Kulkarni, M.S.

    2012-01-01

    The personnel monitoring of more than 80,000 radiation workers in India is at present carried out by semi-automated TLD badge Reader systems (TLDBR-7B) developed by Radiation Safety Systems Division, Bhabha Atomic Research Centre. More than 60 such reader systems are in use in all the personnel monitoring centers in the country. Radiation Safety Systems Division also developed the fully automated TLD badge reader based on a new TLD badge having built-in machine readable ID code (in the form of 16x3 hole pattern). This automated reader is designed with minimum of changes in the electronics and mechanical hardware in the semiautomatic version (TLDBR-7B) so that such semi-automatic readers can be easily upgraded to the fully automated versions by using the new TLD badge with ID code. The reader was capable of reading 50 TLD cards in 90 minutes. Based on the feedback from the users, a new model of frilly automated TLD badge Reader (model VEFFA-10) is designed which is an improved version of the previously reported fully Automated TLD badge reader. This VEFFA-10 PC based Reader incorporates vertical loading of TLD bards having machine readable ID code. In this new reader, a vertical rack, which can hold 100 such cards, is mounted from the right side of the reader system. The TLD card falls into the channel by gravity from where it is taken to the reading position by rack and pinion method. After the readout, the TLD card is dropped in a eject tray. The reader employs hot N 2 gas heating method and the gas flow is controlled by a specially designed digital gas flow meter on the front panel of the reader system. The system design is very compact and simple and card stuck up problem is totally eliminated in the reader system. The reader has a number of self-diagnostic features to ensure a high degree of reliability. This paper reports the performance evaluation of the Reader using 0.4 mm thick Teflon embedded CaSO 4 :Dy TLD cards instead of 0.8 mm cards

  19. Basic requirements of dosemeter systems for individual monitoring of external radiation

    International Nuclear Information System (INIS)

    Boehm, J.; Ambrosi, P.

    1985-01-01

    A plea is made for detailed detector independent requirements for dosemeter systems for individual monitoring of external radiation. These requirements should have their origin in the fundamental aspects and concepts of radiation protection for workers, and should be something like a translation of the general principles of individual monitoring into a language easily understandable by producers and users. This work comprises a summary of the general objectives of individual monitoring and discussion of some relevant requirements for dosemeter systems. (orig.) [de

  20. TLD postal dose quality audit service for Co-60 beams in reference conditions in Cuba

    International Nuclear Information System (INIS)

    Gutierrez Lores, S.; Walwyn Salas, G.; Alonso Villanueva, G.

    2008-01-01

    This report presents the methodology and experience of the Cuban's Secondary Standard Dosimetry Laboratory for the implementation of postal dose quality audits service for Co-60 beams in reference conditions, using TLDs. Under coordinated research project (Contract 10794) were bought (TLD -100) Tl rods type JR 1152F made in China, with dimensions of 6 mm x 1 mm x 1 mm. All of these rods were identified individually with a consecutive number made over one of its sides, using a fine tip of graphite. The method used to determinate the individual sensibility of the TL detectors was: irradiating a group of them, with the same history of irradiation and readout (100 rods approximately), four serial times in the same geometrical conditions, to read them out and to attribute to each of them a sensitivity factor. This sensitivity factor is equal to average for the 4 cycle of irradiation and readout of the quote between the TL readout from dosimeter i and the mean of all values for each cycle. The TLD signal was read using HARSHAW 2000C/B reader. The results obtained in the external verification of the accuracy of the dose determination by the TLD system were performed in cooperation with IAEA Dosimetry Laboratory at Seibersdorf in different years are shown, the results obtained of the quality audits carried out to the different services of radiotherapy of the country are analysed also. The quality audits are an useful tool for the improvement of the accuracy in the dosimetry of clinical beams of radiotherapy with Co-60, contributing this way to the improvement of the life quality to cancer patients of the Cuban system of health. (author)

  1. SU-E-T-222: Investigation of Pre and Post Irradiation Fading of the TLD100 Thermoluminescence Dosimetry for Photon Beams

    Energy Technology Data Exchange (ETDEWEB)

    Sina, S [Radiation Research Center, Shiraz University, Shiraz (Iran, Islamic Republic of); Sadeghi, M [Nuclear Engineering department, Shiraz university, Shiraz (Iran, Islamic Republic of); Faghihi, R [Radiation Research Center, Shiraz University, Shiraz (Iran, Islamic Republic of); Nuclear Engineering department, Shiraz university, Shiraz (Iran, Islamic Republic of)

    2014-06-01

    Purpose: The pre-irradiation and post-irradiation fading of the Thermoluminescense dosimeter signals were investigated in this study. Methods: Two groups of TLD chips with pre-determined ECC values were used in this study. The two groups were divided into 6 series, each composing of 5 TLD chips.The first group was used for pre-irradiation fading. 5 TLDs were exposed to a known amount of radiation from Cs-137 source, and were read out the next day. After seven days, the other 5 TLDs were exposed to the same amount of radiation and were read out after a day. The other series of 5 TLDs were also exposed after 7,19,28, 59, and 90 days, and were read out a day after irradiation. The loss in TLD signal were obtained for all the above cases. The second group, was used for postirradiation fading. All the TLDs of this group were exposed to a known amount of radiation from Cs-137 source. The 6 series composed of 5 TLDs were read out after 1,7,19,28,59, and 90 days. The above-mentioned procedures for obtaining pre-irradiation, and post-irradiation fading were performed for three storage temperatures (25°C, 4°C, and −18°C). Results: According to the results obtained in this study, in case of pre-irradiation fading study, the signal losses after 90 days are 12%, 24%, and 17% for 25°C, 4°C, and −18°C respectively. In case of post-irradiation fading study, the sensitivity losses after 90 days are 25%, 216%, and 20% for 25°C, 4°C, and −18°C respectively. Conclusion: The results indicate that the optimized time between exposing and reading out, and also the optimized time between annealing and exposing is 1 day.The reduction of Storage temperature will reduce the post-irradiation fading, While temperature reduction does not have any effect on pre-irradiation fading.

  2. SU-E-T-222: Investigation of Pre and Post Irradiation Fading of the TLD100 Thermoluminescence Dosimetry for Photon Beams

    International Nuclear Information System (INIS)

    Sina, S; Sadeghi, M; Faghihi, R

    2014-01-01

    Purpose: The pre-irradiation and post-irradiation fading of the Thermoluminescense dosimeter signals were investigated in this study. Methods: Two groups of TLD chips with pre-determined ECC values were used in this study. The two groups were divided into 6 series, each composing of 5 TLD chips.The first group was used for pre-irradiation fading. 5 TLDs were exposed to a known amount of radiation from Cs-137 source, and were read out the next day. After seven days, the other 5 TLDs were exposed to the same amount of radiation and were read out after a day. The other series of 5 TLDs were also exposed after 7,19,28, 59, and 90 days, and were read out a day after irradiation. The loss in TLD signal were obtained for all the above cases. The second group, was used for postirradiation fading. All the TLDs of this group were exposed to a known amount of radiation from Cs-137 source. The 6 series composed of 5 TLDs were read out after 1,7,19,28,59, and 90 days. The above-mentioned procedures for obtaining pre-irradiation, and post-irradiation fading were performed for three storage temperatures (25°C, 4°C, and −18°C). Results: According to the results obtained in this study, in case of pre-irradiation fading study, the signal losses after 90 days are 12%, 24%, and 17% for 25°C, 4°C, and −18°C respectively. In case of post-irradiation fading study, the sensitivity losses after 90 days are 25%, 216%, and 20% for 25°C, 4°C, and −18°C respectively. Conclusion: The results indicate that the optimized time between exposing and reading out, and also the optimized time between annealing and exposing is 1 day.The reduction of Storage temperature will reduce the post-irradiation fading, While temperature reduction does not have any effect on pre-irradiation fading

  3. The role of phantom parameters on the response of the AEOI Neutriran Albedo Neutron Personnel Dosemeter

    International Nuclear Information System (INIS)

    Sohrabi, M.; Katouzi, M.

    1992-01-01

    The response of the AEOI Neutriran Albedo Neutron Personnel Dosemeter (NANPD) which can also be used for other albedo dosemeter types was determined on 18 different phantom configurations. The effects of type, geometry, material, thickness, dosemeter-to-phantom angle in particular with the presence of legs were investigated using a Pu-Be neutron source. It was concluded that the slab phantoms (single or double) and circular and elliptical cylinder phantoms seemed to provide a better response, whereas the ICRU sphere geometry does not seem to be appropriate for the calibration of albedo dosemeters. It is interesting to note that the presence of legs maintains the constancy of the response in a situation when a radiation worker bends down during work. (author)

  4. Energy dependence of ulrathin LiF-dosemeters for high energy electrons and high energy X-radiation

    International Nuclear Information System (INIS)

    Kupfer, T.

    1977-02-01

    The energy dependence of ultrathin LiF-dosemeters for high energy electrons (5-40 MeV) and high energy X-radiation (6 MV, 42 MV) is experimentally determined. The experimental values are compared to values calculted earlier by other authors. The influence of the thickness of the dosemeters have been considered by comparison of experimental values for 0.03 mm thick dosemeters and theoretical values for 0.13 mm and 0.38 mm thick ones. Also different commersially available dosemeters have been compared by experiments. It is difficult to draw any other conclutions about the energy dependence than that the variation of the relative responce is within +- 3 percent (2S). However the results seems to be sulficient for clinical applications

  5. Application of Glow Curve Deconvolution Method to Evaluate Low Dose TLD LiF

    International Nuclear Information System (INIS)

    Kurnia, E; Oetami, H R; Mutiah

    1996-01-01

    Thermoluminescence Dosimeter (TLD), especially LiF:Mg, Ti material, is one of the most practical personal dosimeter in known to date. Dose measurement under 100 uGy using TLD reader is very difficult in high precision level. The software application is used to improve the precision of the TLD reader. The objectives of the research is to compare three Tl-glow curve analysis method irradiated in the range between 5 up to 250 uGy. The first method is manual analysis, dose information is obtained from the area under the glow curve between pre selected temperature limits, and background signal is estimated by a second readout following the first readout. The second method is deconvolution method, separating glow curve into four peaks mathematically and dose information is obtained from area of peak 5, and background signal is eliminated computationally. The third method is deconvolution method but the dose is represented by the sum of area of peak 3,4 and 5. The result shown that the sum of peak 3,4 and 5 method can improve reproducibility six times better than manual analysis for dose 20 uGy, the ability to reduce MMD until 10 uGy rather than 60 uGy with manual analysis or 20 uGy with peak 5 area method. In linearity, the sum of peak 3,4 and 5 method yields exactly linear dose response curve over the entire dose range

  6. Neutron dose measurements of Varian and Elekta linacs by TLD600 and TLD700 dosimeters and comparison with MCNP calculations.

    Science.gov (United States)

    Nedaie, Hassan Ali; Darestani, Hoda; Banaee, Nooshin; Shagholi, Negin; Mohammadi, Kheirollah; Shahvar, Arjang; Bayat, Esmaeel

    2014-01-01

    High-energy linacs produce secondary particles such as neutrons (photoneutron production). The neutrons have the important role during treatment with high energy photons in terms of protection and dose escalation. In this work, neutron dose equivalents of 18 MV Varian and Elekta accelerators are measured by thermoluminescent dosimeter (TLD) 600 and TLD700 detectors and compared with the Monte Carlo calculations. For neutron and photon dose discrimination, first TLDs were calibrated separately by gamma and neutron doses. Gamma calibration was carried out in two procedures; by standard 60Co source and by 18 MV linac photon beam. For neutron calibration by (241)Am-Be source, irradiations were performed in several different time intervals. The Varian and Elekta linac heads and the phantom were simulated by the MCNPX code (v. 2.5). Neutron dose equivalent was calculated in the central axis, on the phantom surface and depths of 1, 2, 3.3, 4, 5, and 6 cm. The maximum photoneutron dose equivalents which calculated by the MCNPX code were 7.06 and 2.37 mSv.Gy(-1) for Varian and Elekta accelerators, respectively, in comparison with 50 and 44 mSv.Gy(-1) achieved by TLDs. All the results showed more photoneutron production in Varian accelerator compared to Elekta. According to the results, it seems that TLD600 and TLD700 pairs are not suitable dosimeters for neutron dosimetry inside the linac field due to high photon flux, while MCNPX code is an appropriate alternative for studying photoneutron production.

  7. On optically stimulated luminescence properties of household salt as a retrospective dosemeter

    International Nuclear Information System (INIS)

    Timar-Gabor, A.; Trandafir, O.

    2013-01-01

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) in the UV (270-370 nm) spectral region have been investigated for five types of table salt (NaCl) available in Romanian supermarkets with a view to applying them in retrospective dosimetry. The salt samples gave bright TL signals with two main peaks at ∼ 100 deg. C and at 300 or 260 deg. C, depending on the origin of the salt and bright OSL signals under continuous stimulation with blue light. The OSL signal (stimulated at 100 deg. C after a pre-heat of 10 s at 150 deg. C) was used for investigations in a standard multiple aliquot procedure. The dose- response was found to be linear in the dose range investigated (up to ∼ 100 mGy) and the lower limit of detection for the samples varied from ∼ 0.01 to 14 mGy. These characteristics, along with the widespread abundance and low cost of household salt, confirm its potential as a retrospective dosemeter. (authors)

  8. Assessment of dose using TLD during activity handling at RPhL, BRIT

    International Nuclear Information System (INIS)

    Choughule, Nitin V.; Bairwa, S.M.; Murali, S.; Rakesh, R.B.; Madhumita, B.; Adtani, M.M.; Mehra, Kiran; Padmanabhan, D.; Borkute, S.D.; Pal, N.; Sachdev, S.S.

    2012-01-01

    Radiopharmaceutical Lab (RPhL), BRIT undertakes production, supply of radiopharmaceuticals. At RPhL short lived isotopes 131 I, 99 Mo, 99m Tc, 125 I, 153 Sm, 32 P and 51 Cr, are handled with total activity handled per week ranging from MBq to TBq (mCiCi). Radiological survey provides idea on radiation level helps to ensure safe working condition. In order to improve the working condition and to estimate the integrated dose over a period of week with uniform pattern of activity handling in the period, a study was carried out using TLD badges. Specifically prepared TLD badges containing CaSO 4 :Dy phosphor were placed at various locations at RPhL It is used for personnel monitoring. One set of TLD was exposed for a week long period while the other set was exposed only during activity handling, kept in the lead pot during the rest of the period. Dose measured by TLDs were compared with the dose estimated using the survey data for the respective locations as well as with the dose estimated using the activity handled by taking into account the time, distance and shielding. The maximum radiation level recorded during lab survey was used to estimate the TLD exposure during the period. It was observed that results on TLD dose measurement and estimated doses using survey results were of same order. The cumulative TLD dose recorded for week duration (168 h) was significantly higher than doses recorded by exposed TLD only during activity handling (8 h). It was expected that the TLD dose would not be more than dose estimated using radiation survey data, while in 3 among 8 experimental TLDs, the dose was ∼ 25% higher. This could be due to the movement of active material or open handling of activity do not get reflected during normal radiation survey and contribution from background radiation at the lab where those TLDs were placed. The individual dose of all the personnel working in different labs were well within the relevant dose limits indicating the safe working condition

  9. Operating experience of an automated TLD dispensing system at CORAL facility

    International Nuclear Information System (INIS)

    Ajoy, K.C.; Dhanasekaran, A.; Arun, R.; Yuvaraj, N.; Karthikeyan, D.; Dheeraj, R.; Akila, R.; Santhanam, R.; Rajagopal, V.; Kumar, Amudhu Ramesh

    2016-01-01

    Monitoring of exposures to occupational workers on individual basis is a regulatory requirement to demonstrate compliance that the dose to the workers is well within the dose limit. Over three decades for monitoring of external exposures, CaSO 4 based Thermo luminescence dosimeters (TLDs), which exhibit the required accuracy, reliability and ruggedness have been employed. TLD cards with unique identification number are loaded in plastic cassettes along with photographs are placed in wooden racks at the entry of the controlled area of the plant. However, there is always a chance that a TLD may be misplaced, used by others or there could be a deliberate act of misuse or abuse. To circumvent this it was decided to install an automated TLD dispensing system with individual TLD tracking as well as locking arrangement. CORAL reprocessing facility at IGCAR was the first to install one such system at Kalpakkam and the operating experience of the system for the last two years is brought out in this paper

  10. Determination of the neutron spectra in the treatment room of a linear accelerator for radiotherapy

    International Nuclear Information System (INIS)

    Vega C, H.R.; Barquero, R.; Mendez, R.; Iniguez, M.P.

    2003-01-01

    By means of a series of measures and Monte Carlo calculations the dosimetric characteristics of the photoneutrons have been determined that take place in volume to a linear accelerator of radiotherapy of 18 MV, LINAC, mark Siemens Mevatron model. The measures were carried out with thermoluminescent dosemeters TLD 600 and TLD 700 that were naked exposed and confined with cover of Cd and Sn, inside a sphere of paraffin and inside spheres Bonner. (Author)

  11. Determination of the neutron spectra in the treatment room of a linear accelerator for radiotherapy; Determinacion de los espectros de neutrones en la sala de tratamiento de un acelerador lineal para radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R. [Universidad Autonoma de Zacatecas, Cuerpo Academico de Radiobiologia, A.P. 336, 98000 Zacatecas (Mexico); Barquero, R. [Hospital Universitario Rio Hortega, Valladolid (Spain); Mendez, R.; Iniguez, M.P. [Depto. de Fisica Teorica, Atomica, Molecular y Nuclear, Universidad de Valladolid, 47011 Valladolid (Spain)

    2003-07-01

    By means of a series of measures and Monte Carlo calculations the dosimetric characteristics of the photoneutrons have been determined that take place in volume to a linear accelerator of radiotherapy of 18 MV, LINAC, mark Siemens Mevatron model. The measures were carried out with thermoluminescent dosemeters TLD 600 and TLD 700 that were naked exposed and confined with cover of Cd and Sn, inside a sphere of paraffin and inside spheres Bonner. (Author)

  12. Glow-peak stability in 6LiF:Mg, Ti (TLD-600) exposed to a Fe-ion beam

    International Nuclear Information System (INIS)

    Yasuda, Hiroshi

    2001-01-01

    The stability of glow peaks in 6 LiF:Mg, Ti (TLD-600) exposed to a high-energy Fe-ion beam was examined in comparison to 137 Cs γ-ray irradiation under changing annealing conditions. The peak areas induced by the Fe ions were much smaller than those by γ-rays. The sizes and positions of peaks 3-5 in Fe-ion irradiated samples were hardly changed after post-annealing at 100 deg C x 30 min, regardless of the pre-annealing conditions (fast quenching or subsequent pre-annealing at 100 deg C x 2 h). Whereas, the peaks in γ-ray irradiated samples were notably affected by post-annealing; the peak positions and peak-area sizes changed in different ways depending on the pre-annealing conditions. The effects of post-annealing on peak 6 were identical for Fe ions and γ-rays. These facts suggest that peaks 3-5 in TLD-600 comprised both stable and unstable luminescent centers, and that the latter part would be easily depleted in highly dense ionization. (author)

  13. Development of radiophotometric dosemeters with high sensitivity using plastic scintillators as a light intensifier

    International Nuclear Information System (INIS)

    Mesquita, C.H. de; Hamada, M.M.

    1987-01-01

    Rectangular plates of plastic scintillators are developed and their effect as light converter evaluated, when used as film-holder in conventional photography dosemeters. In this dosemeter, the radiation that not interacts in the photographic film can be detected by light photons generation in the plastic scintillators, sensitizing the film. (C.G.C.) [pt

  14. Personal radiation monitoring with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Miano, S.C.

    1987-01-01

    The technique of personal dosimetry used by SAPRA (Servico de Assessoria e Protecao Radiologica S/C Ltda., Brazil) is presented. Thermoluminescent monitors and CaSO 4 : Dy are used in pastilles united by teflon. Characteristics of the dosemeters are briefly reported. The system of thermoluminescent measurement, designed and constructed by SAPRA, and the system of personal monitoring are described. (M.A.C.) [pt

  15. IAEA/WHO TLD postal dose audit service and high precision measurements for radiotherapy level dosimetry

    International Nuclear Information System (INIS)

    Izewska, J.; Bera, P.; Vatnitsky, S.

    2002-01-01

    Since 1969 the International Atomic Energy Agency, together with the World Health Organization, has performed postal TLD audits to verify calibration of radiotherapy beams in developing countries. The TLD programme also monitors activities of Secondary Standard Dosimetry Laboratories (SSDLs). The programme has checked approximately 4000 clinical beams in over 1100 hospitals, and in many instances significant errors have been detected in the beam calibration. Subsequent follow-up actions help to resolve the discrepancies, thus preventing further mistreatment of patients. The audits for SSDLs check the implementation of the dosimetry protocol in order to assure proper dissemination of dosimetry standards to the end-users. The TLD audit results for SSDLs show good consistency in the basic dosimetry worldwide. New TLD procedures and equipment have recently been introduced by the IAEA that include a modified TLD calibration methodology and computerised tools for automation of dose calculation from TLD readings. (author)

  16. One year of a thermoluminescent dosemeter and dose record keeping service

    International Nuclear Information System (INIS)

    Dennis, J.A.

    1979-01-01

    A brief description is given of the National Radiological Protection Board's (NRPB) thermoluminescent dosemeter. The automated processing of these dosemeters is linked to a computer-based system of dose records. The postal system is currently used by about 10% of the establishments for which the NRPB provides a personnel monitoring service, but it will soon be extended to other establishments. The distributions of individual whole body doses in 1977 are tabulated. The significant advantage of this new system lies in the improvements in accuracy, completeness, and convenience to the employers of record keeping. (U.K.)

  17. Energy dependence of the supralinearity (f(D)max) of peaks 7 and 8 in the high temperature thermoluminescence of LiF:Mg,Ti (TLD-100) : Interpretation using the Unified Interaction Model

    International Nuclear Information System (INIS)

    Datz, H.; Horowitz, Y.S.; Epstein, L.; Oster, L.; Livingstone, J.; Horowitz, A.; Kol, M.; Margaliot, M.

    2011-01-01

    It is demonstrated that the supralinearity of the dose response of glow peaks 7, 8 in the glow curve of LiF:Mg,Ti (TLD-100) are very strongly dependent on photon/electron energy. Previously published data on f(D) max at photon energies of 1.25 MeV, 100 keV and 8.1 keV effective energy coupled with new data at ∼ 540 keV using 90 Sr/ 90 Y beta rays reveals that the maximum supralinearity f(D) max decreases from values of ∼200 and ∼30 at 1.25 MeV, through intermediate values at 540 keV and 100 keV, to values of ∼ 30 and ∼3 at 8.1 keV effective energy. The normalized dose response f(D) for all energies is modeled using the Unified Interaction Model and the dependence of f(D) max on energy is interpreted as arising from strong dependence of the relative intensity of localized recombination on particle energy (ionization density).

  18. Angular and radial dependence of the energy response factor for LiF-TLD micro-rods in 125I permanent implant source

    International Nuclear Information System (INIS)

    Mobit, P.; Badragan, I.

    2006-01-01

    EGSnrc Monte Carlo simulations were used to calculate the angular and radial dependence of the energy response factor for LiF-thermoluminescence dosemeters (TLDs) irradiated with a commercially available 125 I permanent brachytherapy source. The LiF-TLDs were modelled as cylindrical micro-rods of length 6 mm and with diameters of 1 mm and 5 mm. The results show that for a LiF-TLD micro-rod of 1 mm diameter, the energy response relative to 60 Co gamma rays is 1.406 ± 0.3% for a polar angle of 90 deg. and radial distance of 1.0 cm. When the diameter of the micro-rod is increased from 1 to 5 mm, the energy response decreases to 1.32 ± 0.3% at the same point. The variation with position of the energy response factor is not >5% in a 6 cm x 6 cm x 6 cm calculation grid for the 5 mm diameter micro-rod. The results show that there is a change in the photon spectrum with angle and radial distance, which causes the variation of the energy response. (authors)

  19. NRC TLD Direct Radiation Monitoring Network

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1991-12-01

    This report provides the status and results of the NRC Thermoluminescent Dosimeter (TLD) Direct Radiation Monitoring Network. It presents the radiation levels measured in the vicinity of NRC licensed facilities throughout the country for the third quarter of 1991

  20. The IAEA/WHO thermoluminescent dosimetry intercomparison used for the improvement of clinical dosimetry

    International Nuclear Information System (INIS)

    Racoveanu, N.T.

    1981-01-01

    Results of thermoluminescent dosimetry collected over 5 years in the Eastern Mediterranean region of WHO were analyzed in an attempt to improve clinical dosimetry. Data for 16 radiotherapy departments showed considerable inconsistencies. It was found that the clinical dosemeters used by 3 of the departments were not working properly. The remainder of the departments had one or more dosemeters in perfect working order but the procedure for measuring machine output was inadequate or the correction factors (pressure, temperature) were wrongly applied due to lack of reliable instruments for such measurements. Problems encountered in the sending and returning of TLD dosemeters for assessment are discussed

  1. Performance testing of personal dosemeters from eleven dosimetry services in Sweden

    International Nuclear Information System (INIS)

    Lund, E.; Kylloenen, J.-E.; Grindborg, J.-E.; Lindborg, L.

    2001-01-01

    The Swedish regulation, SSI FS 98:5, requires that radiological workers of category A use dosemeters from an approved personal dosimetry service. The 11 services operating in Sweden at the moment use five different types of dosemeter. All have been tested for their ability to determine H p (10) and some of them to determine H p (0.07) according to the European Commission report Radiation Protection 73, EUR 14852, of 1994. The five unique systems have been tested regarding the angular and energy dependence of the response of the dosemeters. The test points for the determination of H p (10) are all, except one, within the trumpet curve and for the unique systems it is shown that the uncertainty related to angular response at three different energies is within the required ±40% except for the lowest X ray quality 40 kV. The energy dependence dominates over the directional dependence and the choice of radiation quality for calibration is of great importance for the system performance. (author)

  2. Validation of a MOSFET dosemeter system for determining the absorbed and effective radiation doses in diagnostic radiology.

    Science.gov (United States)

    Manninen, A-L; Kotiaho, A; Nikkinen, J; Nieminen, M T

    2015-04-01

    This study aimed to validate a MOSFET dosemeter system for determining absorbed and effective doses (EDs) in the dose and energy range used in diagnostic radiology. Energy dependence, dose linearity and repeatability of the dosemeter were examined. The absorbed doses (ADs) were compared at anterior-posterior projection and the EDs were determined at posterior-anterior, anterior-posterior and lateral projections of thoracic imaging using an anthropomorphic phantom. The radiation exposures were made using digital radiography systems. This study revealed that the MOSFET system with high sensitivity bias supply set-up is sufficiently accurate for AD and ED determination. The dosemeter is recommended to be calibrated for energies 80 kVp. The entrance skin dose level should be at least 5 mGy to minimise the deviation of the individual dosemeter dose. For ED determination, dosemeters should be implanted perpendicular to the surface of the phantom to prevent the angular dependence error. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Comparative measurements of external radiation exposure using mobile phones, dental ceramic, household salt and conventional personal dosemeters

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Bulánek, Boris; Judas, Libor

    2015-01-01

    Because retrospective dosimetry utilises commonly occurring materials and objects, it is particularly useful in cases of large-scale radiation accidents or malevolent acts with radioactive materials where casualties are inflicted on the general public and first emergency responders. The aim of this study was to investigate whether retrospective dosemeters can provide dose estimates with comparable accuracy like conventional personal dosemeters. Using an external source of radiation 137 Cs and an anthropomorphic phantom, we simulated serious irradiation of a human body in anterior-posterior and rotational geometries. Retrospective luminescence dosimetry objects, such as mobile phones, dental ceramic and household salt, and conventional personal dosemeters (thermoluminescent and electronic) were fixed to the anthropomorphic phantom. The doses obtained were compared with specific reference values. In most cases, relative deviations between the measured doses and the reference values did not exceed 20%. As the retrospective and conventional dosemeters show no significant differences in laboratory conditions, the retrospective luminescence dosimetry objects represent a very promising tool if handled properly. - Highlights: • A serious external exposure of human body was simulated. • Doses were measured using both retrospective and conventional dosemeters. • Utilised retrospective dosimetry materials were alumina resistors from mobile phones, household salt and dental ceramic. • Doses obtained were compared with reference values. • Both retrospective and conventional dosemeters gave similar results

  4. Dose estimation by simultaneous measurement of the radon/thoron concentration and the equilibrium factors in air using a passive dosemeter

    International Nuclear Information System (INIS)

    Urban, M.

    1984-03-01

    Responsible for an increased radiation exposure is the inhalation of radon and its short lived daughters. A time integrating passive dosemeter was developed to determine the concentrations of the radon isotopes as well as their equilibrium factors. The α energy spectrum inside a dosemeter is measured by means of a nuclear track detector. The concentrations in air and the equilibrium factors are calculated by using a new mathematical dosemeter model. A small pilot study in houses was done to test the dosemeter. (orig.) [de

  5. Neutron area monitor with TLD pairs

    International Nuclear Information System (INIS)

    Guzman G, K. A.; Borja H, C. G.; Valero L, C.; Hernandez D, V. M.; Vega C, H. R.

    2011-11-01

    The response of a passive neutron area monitor with pairs of thermoluminescent dosimeters has been calculated using the Monte Carlo code MCNP5. The response was calculated for one TLD 600 located at the center of a polyethylene cylinder, as moderator. When neutrons collide with the moderator lose their energy reaching the TLD with thermal energies where the ambient dose equivalent is calculated. The response was calculated for 47 monoenergetic neutron sources ranging from 1E(-9) to 20 MeV. Response was calculated using two irradiation geometries, one with an upper source and another with a lateral source. For both irradiation schemes the response was calculated with the TLDs in two positions, one parallel to the source and another perpendicular to the source. The advantage of this passive neutron monitor area is that can be used in locations with intense, pulsed and mixed radiation fields. (Author)

  6. Analysis of results from intercomparison among Spanish laboratories involved of photon energy ''137 Cs for environmental dosimetry laboratories

    International Nuclear Information System (INIS)

    Gonzalez, A.M.; Brosed, A.; Salas, R.

    2003-01-01

    Any environmental thermoluminescent dosemeter (TLD) system must be periodically calibrated at a calibration laboratory. In this frame, the Consejo de Seguridad Nuclear (CSN) has performed an intercomparison among Spanish laboratories involved in environmental monitoring, by means of TLD, in order to verify the traceability of the whole dosimeter and reader to the national standard for the protection quantities of interest for a given photon energy (''137Cs). To achieve this goal the CSN asked the Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT) to carry out the reference irradiations in the energy above mentioned at the lonising Radiations Metrology Unit headquarters. Nine laboratories have participated. All the dosemeters were irradiated with the same air kerma rate. The radiological quantity used was the ambient dose equivalent, H (10), and the values of this quantity assigned to each laboratory were between 210 and 360 μSv. All the dosemeters of the participating laboratories met the two analysis criteria used. All of them demonstrated a satisfactory fulfilment of the requirements established by so called trumpet curves and of the requirements established by the ANSI 1311. (Author) 7 refs

  7. Centralized TLD service and record keeping in Canada

    International Nuclear Information System (INIS)

    Grogan, D.; Ashmore, J.P.; Bradley, R.P.

    1979-01-01

    A centralized automated TLD service operated by the Department of National Health and Welfare went into operation in May 1977 to monitor radiation workers throughout Canada. Twenty-thousand employees from a wide range of disciplines are enrolled and the number will be increased to fifty thousand by September l978. A prototype of the system, operational from September 1976 to May 1977 for three-thousand people, has already been described. A description of technical and operational highlights is presented as well as a description of problems experienced during the first full year of operation. Details of costs, conversion logistics, operational performance and technical problems are included. A comparison of the advantages and disadvantages of changing from film dosimetry to TLD in a nationwide context is detailed. The dose meter read-out unit is interfaced, through video terminals, with a time-sharing computer system programmed to provide direct access to the Canadian National Dose Registry. Details of this linkage are described, as are the computer programmes for routine processing of raw batch data. The centralized TLD service interactively linked with the National Dose Registry provides a comprehensive occupational monitoring programme invaluable for regulatory control. (author)

  8. Measurements of environmental background radiation levels by TLD in and around the Jahangirnagar University Campus

    International Nuclear Information System (INIS)

    Mollah, A.S.; Aleya Begum; Idris Miah, M.; Yunus, Afrozi

    1997-01-01

    The background radiation levels at 30 locations in and around the Jahangirnagar University Campus (JUC) were measured using a LiF(TLD-100) thermoluminescent dosimeter (TLD). In addition, dose rates at three pre-selected locations were measured on a monthly as well as quarterly basis for one year period (July 1993 - June 1994). The dose rate ranges from 1016 to 2167 μSv.y -1 (101.6 to 216.7 mrem.y -1 ) with a mean value of 1595 μSv.y -1 (159.5 mrem.y -1 ). These values are comparable with those of pre- and post-operational values for the reactor site. The estimated average annual effective dose equivalent to the inhabitants at the study areas was found to be 1276 μSv (127.6 mrem). Variation of background radiation level with meteorological parameters, namely, temperature, rainfall, relative humidity and pressure was also studied. The influence on the dose rate of the meteorological parameters was observed. (author)

  9. Performance of a PADC personal neutron dosemeter at simulated and real workplace fields of the nuclear industry

    International Nuclear Information System (INIS)

    Fiechtner, A.; Boschung, M.; Wernli, C.

    2007-01-01

    In the framework of the EVIDOS (Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields) project, funded by the EC, measurements with PADC personal neutron dosemeters were carried out at several workplace fields of the nuclear industry and at simulated workplace fields. The measured personal neutron dose equivalents of the PADC personal neutron dosemeter are compared with values that were assessed within the EVIDOS project by other partners. The detection limits for different spectra types are given. In cases were the neutron dose was too low to be measured by the PADC personal neutron dosemeter, the response is estimated by convoluting the responses to monoenergetic neutrons with the dose energy distribution measured within EVIDOS. The advantages and limitations of the PADC personal neutron dosemeter are discussed. (authors)

  10. Clasificación y eficiencia del Sistema Portuario Español

    Directory of Open Access Journals (Sweden)

    Sala Garrido, Ramon

    2007-01-01

    Full Text Available El actual proceso de innovación tecnológica, alentado por una creciente liberalización y globalización de las economías a nivel internacional, ha propiciado importantes cambios en la organización y gestión de la industria marítima y portuaria que afectan significativamente a la productividad y eficiencia de las actividades desarrolladas en los puertos. En este contexto, la competitividad de nuestro país depende, en gran medida, del desarrollo de los sistemas de transporte, y en particular, de la existencia de unos puertos eficientes que permitan el trasvase de mercancías de un modo ágil y seguro. Por todo ello, en este documento analizamos la eficiencia de los principales puertos del Sistema Portuario Español (SPE usando la metodología DEA (Análisis Envolvente de Datos. El estudio de los niveles de eficiencia alcanzados en los años precedentes por los distintos puertos que componen el SPE, nos permitirá analizar la evolución en los niveles de eficiencia de los mismos con el objeto de llegar a recomendaciones que permitan mejorarla en el futuro. Siendo conscientes de la complejidad y gran diversidad de los puertos que conforman el actual SPE proponemos el estudio previo de la estructura del sistema. El conocimiento de los distintos subsistemas que conforman el SPE nos permite definir grupos homogéneos de puertos en los que promover medidas específicas y diferenciadas que contribuyan a mejorar su eficiencia.

  11. A neutron dosemeter for nuclear criticality accidents.

    Science.gov (United States)

    d'Errico, F; Curzio, G; Ciolini, R; Del Gratta, A; Nath, R

    2004-01-01

    A neutron dosemeter which offers instant read-out has been developed for nuclear criticality accidents. The system is based on gels containing emulsions of superheated dichlorodifluoromethane droplets, which vaporise into bubbles upon neutron irradiation. The expansion of these bubbles displaces an equivalent volume of gel into a graduated pipette, providing an immediate measure of the dose. Instant read-out is achieved using an array of transmissive optical sensors which consist of coupled LED emitters and phototransistor receivers. When the gel displaced in the pipette crosses the sensing region of the photomicrosensors, it generates a signal collected on a computer through a dedicated acquisition board. The performance of the device was tested during the 2002 International Accident Dosimetry Intercomparison in Valduc, France. The dosemeter was able to follow the initial dose gradient of a simulated accident, providing accurate values of neutron kerma; however, the emulsion was rapidly depleted of all its drops. A model of the depletion effects was developed and it indicates that an adequate dynamic range of the dose response can be achieved by using emulsions of smaller droplets.

  12. A neutron dosemeter for nuclear criticality accidents

    International Nuclear Information System (INIS)

    D'Errico, F.; Curzio, G.; Ciolini, R.; Del Gratta, A.; Nath, R.

    2004-01-01

    A neutron dosemeter which offers instant read-out has been developed for nuclear criticality accidents. The system is based on gels containing emulsions of superheated dichlorodifluoromethane droplets, which vaporise into bubbles upon neutron irradiation. The expansion of these bubbles displaces an equivalent volume of gel into a graduated pipette, providing an immediate measure of the dose. Instant read-out is achieved using an array of transmissive optical sensors which consist of coupled LED emitters and phototransistor receivers. When the gel displaced in the pipette crosses the sensing region of the photo microsensors, it generates a signal collected on a computer through a dedicated acquisition board. The performance of the device was tested during the 2002 International Accident Dosimetry Intercomparison in Valduc (France)). The dosemeter was able to follow the initial dose gradient of a simulated accident, providing accurate values of neutron kerma; however, the emulsion was rapidly depleted of all its drops. A model of the depletion effects was developed and it indicates that an adequate dynamic range of the dose response can be achieved by using emulsions of smaller droplets. (authors)

  13. TLD Postal service for quality audits of beams of Co-60 in reference conditions in Cuba; Servicio Postal TLD para auditorias de calidad de haces de Co-60 en condiciones de referencia en Cuba

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez L, S.; Walwyn S, G.; Alonso V, G. [CPHR, Calle 20 No. 4113 e/41 y 47, Playa, C.P. 11300, C. Habana (Cuba)]. e-mail: stefan@cphr.edu.cu

    2006-07-01

    Purpose: To describe the methodology and experience of the Secondary Laboratory of Dosimetric Calibration of Cuba in the establishment of the TLD Postal Service for quality audits of beams of Co-60 in reference conditions. Materials and methods: Through the Coordinated Project of Research (Contract 10794) its was bought 200 solid thermoluminescent detectors of LiF: Mg, Ti (TLD-100) in micro bars form with dimensions of 6 x 1 x 1 mm and of the JR 1152F type manufactured in China. All these detectors were identified individually with a serial number on one of its faces, using a graphite fine sheet. Those detectors for its irradiation are introduced in cylindrical plastic capsules developed and used by the International Atomic Energy Agency (IAEA) in the Audit Postal Service of Dose IAEA/WHO, the capsules have one cavity equal to 3 mm for that is necessary to recover this cavity with a fine plastic tube so that the detectors remain immobile during the irradiation. The method used to determine the individual sensitivity of the thermoluminescent detectors is: to irradiate a detectors group (100 micro bars) 4 times in those same geometric conditions, with the same irradiation history and reading, then it is determine for each detector a sensitivity factor equal to the average of those readings obtained for the 4 irradiation cycles for each i detector among the average of all the reading values obtained during the 4 cycles. The thermoluminescent signal is obtained with a Harshaw 2000C/B reader manual. Results: The satisfactory results obtained in the verification of the calibration of the TLD system, using the reference irradiation service of the Seibersdorf Dosimetry Laboratory of the IAEA in three different years are shown. The results of the audits carried out to the different radiotherapy services of the country in different years are also presented. Conclusions: The experience with the detectors acquired in the project demonstrates that with an appropriate

  14. NRC TLD Direct Radiation Monitoring Network. Progress report, January-June 1981

    International Nuclear Information System (INIS)

    1982-04-01

    This report provides the status and results of the NRC Thermoluminescent Dosimeter (TLD) Direct Radiation Monitoring Network. It presents the radiation levels measured in the vicinity of 55 NRC-licensed facility sites throughout the country for the first half of 1981. The program objectives, scope, and methodology are given. The TLD system, dosimeter location, data processing scheme, and quality assurance program are outlined

  15. Development of an improved dosemeter for assessments of risk to the eye

    International Nuclear Information System (INIS)

    Eakins, J.S.; Gilvin, P.J.; Hager, L.G.; Tanner, R.J.

    2014-01-01

    To develop an improved dosemeter to assess photon and beta exposures of the eye lens, and in response to issues surrounding the preferred values of H lens to be used for guiding operational radiation protection, a programme of re-optimization of the current PHE thermoluminescence dosemeter has been performed. In particular, refinements of the filter located in front of the sensitive 7 LiF:Mg,Cu,P element have been considered, so that the dose response characteristics of the device provide a better and more conservative estimate of risk. The investigation was performed using the Monte Carlo modelling software MCNP5, to produce a final design that featured a filter containing a 9.5 mm diameter polypropylene hemisphere truncated to a maximum thickness of 3.0 mm. The responses of this design in photon and electron fields are presented here, contrasted against those of the existing PHE eye dosemeter, with respect to the operational quantity H p (3,E,θ) and both current and suggested values for the absorbed dose per fluence risk profile for the lens of the eye. - Highlights: • A programme of re-optimization of the current PHE eye dosemeter has been performed. • A design featuring a truncated hemispherical filter was found to be optimal. • The shape of the filter better resembles the rotational profile of the eye. • Response characteristics depend on the calibration conditions taken to provide the best risk estimate

  16. Calibration of thermoluminescence skin dosemeter response to beta emitters found in Ontario Hydro nuclear power stations

    International Nuclear Information System (INIS)

    Walsh, M.L.; Agnew, D.A.; Donnelly, K.E.

    1984-01-01

    The response of the Ontario Hydro Thermoluminescence Dosimetry System to beta radiation in nuclear power station environments was evaluated. Synthetic beta spectra were constructed, based on activity samples from heat transport systems and fuelling machine contamination smears at nuclear power stations. Using these spectra and dosemeter energy response functions, an overall response factor for the skin dosemeter relative to skin dose at 7 mg.cm -2 was calculated. This calculation was done assuming three specific geometries: (1) an infinite uniformly contaminated plane source at a distance of 33 cm (50 mg.cm -2 total shielding) from the receptor; (2) an infinite cloud surrounding the receptor; (3) a point source at 33 cm. Based on these calculations, a conservative response factor of 0.7 has been chosen. This provides an equation for skin dose assignment, i.e. Skin Dose = 1.4 x Skin Dosemeter Reading when the skin dosemeter is directly calibrated in mGy(gamma). (author)

  17. Radiation protection cabin for catheter-directed liver interventions: operator dose assessment

    International Nuclear Information System (INIS)

    Maleux, Geert; Bosmans, Hilde; Bergans, Niki; Bogaerts, Ria

    2016-01-01

    The number and complexity of interventional radiological procedures and in particular catheter-directed liver interventions have increased substantially. The current study investigates the reduction of personal doses when using a dedicated radiation protection cabin (RPC) for these procedures. Operator and assistant doses were assessed for 3 series of 20 chemo-infusion/chemoembolisation interventions, including an equal number of procedures with and without RPC. Whole body doses, finger doses and doses at the level of knees and eyes were evaluated with different types of TLD-100 Harshaw dosemeters. Dosemeters were also attached on the three walls of the RPC. The operator doses were significantly reduced by the RPC, but also without RPC, the doses appear to be limited as a result of thorough optimisation with existing radiation protection tools. The added value of the RPC should thus be determined by the outcome of balancing dose reduction and other aspects such as ergonomic benefits. (authors)

  18. Systematic processing of the external individual monitoring data obtained by photographic film and capacitor dosemeters

    International Nuclear Information System (INIS)

    Krueger, F.; Shtuk, D.

    1983-01-01

    Individual radiation load measurements have been carried out both with photographic film and capacitor type dosemeters (CD). Systematic statistics methods were applied for the obtained data processing. The CD data were shown to exceed those measured with the film dosemeters. Specific features of the CD application are revealed that should be taken into account in practice [ru

  19. Evaluation of TLD dose response compared to MCNP-5 simulation of diagnostic X ray equipment - radiation diagnostic image

    International Nuclear Information System (INIS)

    Sanchez G, R.; Cavalieri, T. A.; De Paiva, F.; Dalledone S, P. de T.; Yoriyaz, H.; Rodrigues F, M. A.; Vivolo, V.

    2014-08-01

    The thermo luminescent dosimeter (TLD) is used as a radiation dosimeter and can be used as environmental and staff personnel monitoring. The TLD measures ionizing radiation exposure by a process in which the amount of radiation collected by the dosimeter is converted in visible light when the crystal is heated. The amount of emitted light is proportional to the radiation exposure, and then the response of the TLD must be the related to the real dose. In this work it was used twenty four TLD 700 in order to obtain eight values of doses from a diagnostic X-ray equipment. The TLD-700 is a LiF TLD enriched with 7 Li isotope. One way to compare and study the response of TLD is by Monte Carlo method, which has been used as a computational tool to solve problems stochastically. This method can be applied to any geometry, even those where the boundary conditions are unknown, making the method particularly useful to solve problems a priori. In this work it was modeled the X-ray tube exactly as the one used to irradiate the TLD, after the simulation and the TLD irradiation the results of dose value from both were compared. (Author)

  20. Evaluation of TLD dose response compared to MCNP-5 simulation of diagnostic X ray equipment - radiation diagnostic image

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez G, R.; Cavalieri, T. A.; De Paiva, F.; Dalledone S, P. de T.; Yoriyaz, H. [Instituto de Pesquisas Energeticas e Nucleares, Centro de Engenharia Nuclear / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Rodrigues F, M. A. [Universidade Estadual Paulista, Faculdade de Medicina de Botucatu, Departamento de Dermatologia e Radioterapia, Av. Prof. Montenegro s/n, Rubiao Junior, 18601-970 Botucatu (Brazil); Vivolo, V., E-mail: chancez@hotmail.com [Instituto de Pesquisas Energeticas e Nucleares, Gerencia de Metrologia das Radiacoes / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The thermo luminescent dosimeter (TLD) is used as a radiation dosimeter and can be used as environmental and staff personnel monitoring. The TLD measures ionizing radiation exposure by a process in which the amount of radiation collected by the dosimeter is converted in visible light when the crystal is heated. The amount of emitted light is proportional to the radiation exposure, and then the response of the TLD must be the related to the real dose. In this work it was used twenty four TLD 700 in order to obtain eight values of doses from a diagnostic X-ray equipment. The TLD-700 is a LiF TLD enriched with {sup 7}Li isotope. One way to compare and study the response of TLD is by Monte Carlo method, which has been used as a computational tool to solve problems stochastically. This method can be applied to any geometry, even those where the boundary conditions are unknown, making the method particularly useful to solve problems a priori. In this work it was modeled the X-ray tube exactly as the one used to irradiate the TLD, after the simulation and the TLD irradiation the results of dose value from both were compared. (Author)

  1. Eficiencia en el uso de los medicamentos

    Directory of Open Access Journals (Sweden)

    Julián Pérez Peña

    2003-04-01

    Full Text Available Se presenta el tema de la eficiencia del uso de los medicamentos. Se estudian las diferentes acciones asociadas con el uso como la selección, las guías terapéuticas, las terapéuticas no farmacológicas, el monitoreo de la prescripción y utilización de los medicamentos, así como la importancia de la información terapéutica independiente y su impacto en la eficiencia de la utilización de fármacos.The topic of the drug use efficiency is dealt with. The different actions associated with it as the selection, the therapeutic guides, the non-pharmacological therapeutics, the monitoring of the prescription and the utilization of drugs, as well as the independent therapeutic information and its impact on the efficiency of drug use are studied.

  2. New generation of ''legal'' dosemeters

    International Nuclear Information System (INIS)

    Fletcher, R.

    1991-01-01

    In the early 1980s research at the National Radiological Protection Board in the UK proved the feasibility of using solid state electronics in an entirely new dosimetry technology - capable of reaching right down into the low energy photon ranges, and able to detect beta radiation. In 1988 the NRPB undertook a joint venture with Siemens Plessey Controls to develop a marketable personal dosemeter meeting full Health and Safety Executive approval as a ''legal'' instrument. The Electronic Personal Dosemeter (EPD) was thus conceived, and will reach the pre-production stage early this year. The EPD makes use of state-of-the-art silicon integrated circuit technology, with a custom amplifier and microprocessor system. The liquid crystal display continuously shows the accumulated short-term penetrating dose in terms of the Hp (10) unit, and can also show superficial dose and dose rates. Because the EPD must be continuously powered, the custom lithium battery was commissioned to ensure a minimum service interval of 12 months. The EPD is the size and weight of a small pocket pager. Although dose data can be read directly from the EPD, a comprehensive data management system is needed to effect real-life use in industry. The EPD thus communicates by infra-red link to a reader unit which interfaces an IBM-compatible PC, allowing authorized personnel to read the dose memories and perform dose alarm threshold settings. (author)

  3. An intercomparison of the thermoluminescent efficiency of various preparations of lithium fluoride

    CERN Document Server

    Driscoll, C M H

    1977-01-01

    Possible alternative sources of supply of lithium fluoride to that used at present in the NRPB automated TLD system dosemeter are being considered on the grounds of economy and quality control. Initial measurements on the thermoluminescent properties and efficiency of various preparations of lithium fluoride are described, including the Harshaw TLD-700 which is currently in use in the automated thermoluminescent dosemeter. Material obtained from British Nuclear Fuels Ltd (which may be an atypical batch) showed 75% of the sensitivity of the Harshaw material, with around 20% fading of the signal after 1 month's storage. French material, obtained from Desmarquest and Carbonisation Entreprise et Ceramique and used by the Commissariat a l'Energie Atomique, showed good fading resistance but, after standard preparational treatments, was only half as sensitive in the thermoluminescent response. Without additional treatments to improve the characteristics of these materials, they cannot be considered as being satisfac...

  4. Personal dosimetry TLD 100 in orthopedic surgeons exposed to ionizing radiation in Bogota - Colombia; Dosimetria personal TLD 110 en medicos ortopedistas expuestos a radiacion ionizante en Bogota - Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Sierra C, B. Y.; Jimenez, Y. [Universidad Nacional de Colombia, Departamento de Fisica, Grupo de Fisica Medica, Carrera 45 No. 26-85, Bogota (Colombia); Plazas, M. C. [Hospital Universitario Fundacion Santa Fe de Bogota, Instituto de Oncologia Carlos Ardila Lulle, Calle 119, No. 7-90, 220246 Bogota (Colombia); Eslava S, J. [Universidad Nacional de Colombia, Instituto de Investigaciones Clinicas, Grupo Equidad en Salud, Carrera 45 No. 26-85, Bogota (Colombia); Groot R, H., E-mail: brigith.sierra@gmail.com [Universidad de los Andes, Laboratorio de Genetica Humana, Carrera 1 No. 18A -12, Bogota (Colombia)

    2014-08-15

    Orthopedic surgeons should be considered as professionals occupationally exposed to ionizing radiation, for using C arc (fluoroscope) an equipment of X type radiation emission, during surgical procedures for imaging generation. Some health institutes, use of C arc under uncontrolled circumstances, such a lack of dosimetry control, incomplete or absence of personnel protective elements and protective measures, which in turn, lead to a high exposition to the personnel. Materials and methods. Study of double match cohort by age and gender, was conducted, in four health institutions of second and third level of attention in Bogota city. Personal dosimetry measurements with TLD-100 dosimetry crystals in both cohorts and environmental dosimetry in each of operation rooms used for orthopedic procedures, were carry out during six months of follow up. Dosimetry crystals were read in a Harshaw 4500 - Bicron equipment, in the Medical Physics Laboratory of National University of Colombia. Results. Dosimetry measurements are compatibles with those of occupationally exposed personnel 3.44 mSv/6 m CI 95% (1.66-3.99), even does not overpass ICRP recommendations, are higher as were expect at the beginning of the study. The median of effective accumulative dose in thorax is 3,4 mSv CI 95% (1,66-3,99), higher in comparison with neck value 2,7 mSv CI 95% (1,73-3,80) and hand dosimetry 1,42 mSv CI 95% (0,96-2,34). Conclusions: Orthopedic surgeons should be considered occupational exposed to ionizing radiation, who has to accomplish to the radiological protection measures, dosimetric follow up and maintenance of the used X ray equipment. It was confirm throughout this study that dosimetry shows higher levels as expected at the beginning of the study, compatible with occupationally exposed personnel. (Author)

  5. Periodicity of TLD badge personnel monitoring service in India

    International Nuclear Information System (INIS)

    Kher, R.K.; Joshi, V.D.; Kaushik, Aruna; Sharma, Amiy; Chatterjee, S.

    2003-01-01

    The periodicity of an individual monitoring service is an important aspect. Presently minimum period for TLD badge service is maintained as 'calendar month' and choice of quarterly service is also offered. The periodicity of the TLD service for a given category/application type of institution, is to be fixed taking into account level of average occupational doses in all or typical institutions of given category and other information indicating the status of safety and possible fluctuations of exposure levels and potential for overexposure cases. This paper presents the status on the periodicity of TLD Badge Service as is evolved and adopted for the four broad categories i.e. DAE (Nuclear Fuel Cycle) Institutions, Industrial, Medical, Research institutions. It is concluded that quarterly service is a convenient option for institution categories where type of work/workload, and work practices are such that occupational exposures could be normally kept below about one mSv or so in the monitoring period, average annual dose less than 1 mSv and persons receiving annual dose >10 mSv is less than 1% of total in the category. Also, the judicious use of the flexibility in the periodicity of TLD Badge service would help (i) to keep the monitoring related workload to the optimum for the monitoring units and (ii) to keep the expenses incurred by the institution towards monitoring to the minimum without sacrificing radiation safety (iii) to focus the extra monitoring efforts on the applications/situations requiring improvement in radiation safety. (author)

  6. Unbiased metal oxide semiconductor ionising radiation dosemeter

    International Nuclear Information System (INIS)

    Kumurdjian, N.; Sarrabayrouse, G.J.

    1995-01-01

    To assess the application of MOS devices as low dose rate dosemeters, the sensitivity is the major factor although little studies have been performed on that subject. It is studied here, as well as thermal stability and linearity of the response curve. Other advantages are specified such as large measurable dose range, low cost, small size, possibility of integration. (D.L.)

  7. Direct measurement of annual β dose using TLD on porcelain

    International Nuclear Information System (INIS)

    Leung, P.L.; Stokes, M.J.; Xia Junding; Wang Weida; Zhou Zhixin

    1999-01-01

    In order to improve accuracy of TL authentication test for porcelain, a method of direct measurement of annual β dose using ultrathin TLD (CaSO 4 :Tm) on porcelain was studied. Since the TLD was placed into a hole left after sampling for the TL measurement, the method will not cause any new damage to the studied object. The results show that the technique is suitable for measuring annual β dose and improving accuracy of TL authentication test for both porcelain and pottery

  8. Developmental roles of the BMP1/TLD metalloproteinases.

    Science.gov (United States)

    Ge, Gaoxiang; Greenspan, Daniel S

    2006-03-01

    The astacin family (M12A) of the metzincin subclan MA(M) of metalloproteinases has been detected in developing and mature individuals of species that range from hydra to humans. Functions of this family of metalloproteinase vary from digestive degradation of polypeptides, to biosynthetic processing of extracellular proteins, to activation of growth factors. This review will focus on a small subgroup of the astacin family; the bone morphogenetic protein 1 (BMP1)/Tolloid (TLD)-like metalloproteinases. In vertebrates, the BMP1/TLD-like metalloproteinases play key roles in regulating formation of the extracellular matrix (ECM) via biosynthetic processing of various precursor proteins into mature functional enzymes, structural proteins, and proteins involved in initiating mineralization of the ECM of hard tissues. Roles in ECM formation include: processing of the C-propeptides of procollagens types I-III, to yield the major fibrous components of vertebrate ECM; proteolytic activation of the enzyme lysyl oxidase, necessary to formation of covalent cross-links in collagen and elastic fibers; processing of NH2-terminal globular domains and C-propeptides of types V and XI procollagen chains to yield monomers that are incorporated into and control the diameters of collagen type I and II fibrils, respectively; processing of precursors for laminin 5 and collagen type VII, both of which are involved in securing epidermis to underlying dermis; and maturation of small leucine-rich proteoglycans. The BMP1/TLD-related metalloproteinases are also capable of activating the vertebrate transforming growth factor-beta (TGF-beta)-like "chalones" growth differentiation factor 8 (GDF8, also known as myostatin), and GDF11 (also known as BMP11), involved in negative feedback inhibition of muscle and neural tissue growth, respectively; by freeing them from noncovalent latent complexes with their cleaved prodomains. BMP1/TLD-like proteinases also liberate the vertebrate TGF

  9. Postal TLD audits in radiotherapy in the Czech Republic: current status, experience and potential

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Kapucianova, Michaela; Dufek, Vladimir

    2014-01-01

    The paper deals with practice and performance of postal TLD audits in radiotherapy with emphasis on the possibilities of application of the advanced versions that were developed following up technological progress in radiotherapy. The new methodologies of the TLD audit are focused specifically on up-to-date linear accelerators, equipped with multileaf collimators, and modern treatment planning systems. The dose is checked by the TLD not only for reference conditions but also in conditions of radiation fields influenced by presence of inhomogeneities in the irradiated volume. As regards small radiation fields, the check also includes dose profile verification using gafchromic films. The methodologies were tested within pilot studies performed in collaboration with some Czech radiotherapy centers. The results and experience gave evidence of the usefulness and appropriateness of the new TLD audit methodologies. (orig.)

  10. A Pb-TLD spectrometer to measure high energy photons in z-pinch experiments on the primary test stand

    International Nuclear Information System (INIS)

    Si, Fenni; Yang, Jianlun; Xu, Rongkun; Yuan, Xi; Huang, Zhanchang; Ye, Fan; Wang, Dong; Zhang, Chuanfei

    2017-01-01

    Highlights: • A Pb-TLD spectrometer has been developed to measure spectra of high energy photons in wire-array z pinches on PTS. • Energy spectra of high energy photons on PTS has been firstly obtained by unfolding programs developed with MATLAB code. • The energy of high energy x-ray on PTS is obtained to be mainly within the region of 100 keV to 1.3 MeV. - Abstract: A Pb-TLD spectrometer has been developed based on attenuation techniques to measure high energy photons in wire-array z-pinch experiments on the primary test stand (PTS). It is composed of a stack of 18 lead filters interspersed with 19 thermoluminescent dosimeters (TLD). A shield is constructed for the spectrometer and scattered radiation is reduced to less than 5% by the shield. Response functions of the spectrometer are calculated by MCNP5 for 0–2 MeV photons. Based on response functions and 19 dose data measured in experiments, energy spectra of high energy photons on PTS has been firstly obtained by unfolding programs developed with MATLAB code using iterative least square fit. Results show that energy peak locates within 200 keV and 300 keV, and the fluence decreases to background level at energy higher than 1.3 MeV.

  11. A Pb-TLD spectrometer to measure high energy photons in z-pinch experiments on the primary test stand

    Energy Technology Data Exchange (ETDEWEB)

    Si, Fenni; Yang, Jianlun; Xu, Rongkun; Yuan, Xi; Huang, Zhanchang; Ye, Fan; Wang, Dong; Zhang, Chuanfei, E-mail: sifenni@163.com

    2017-05-15

    Highlights: • A Pb-TLD spectrometer has been developed to measure spectra of high energy photons in wire-array z pinches on PTS. • Energy spectra of high energy photons on PTS has been firstly obtained by unfolding programs developed with MATLAB code. • The energy of high energy x-ray on PTS is obtained to be mainly within the region of 100 keV to 1.3 MeV. - Abstract: A Pb-TLD spectrometer has been developed based on attenuation techniques to measure high energy photons in wire-array z-pinch experiments on the primary test stand (PTS). It is composed of a stack of 18 lead filters interspersed with 19 thermoluminescent dosimeters (TLD). A shield is constructed for the spectrometer and scattered radiation is reduced to less than 5% by the shield. Response functions of the spectrometer are calculated by MCNP5 for 0–2 MeV photons. Based on response functions and 19 dose data measured in experiments, energy spectra of high energy photons on PTS has been firstly obtained by unfolding programs developed with MATLAB code using iterative least square fit. Results show that energy peak locates within 200 keV and 300 keV, and the fluence decreases to background level at energy higher than 1.3 MeV.

  12. Two miniature electronic dosemeters Yperwatch - Gamcard

    International Nuclear Information System (INIS)

    Clavel, B.; Jaillon, J.

    1993-01-01

    Yperwatch and Gamcard were miniature electronic gamma personal dose and dose rate monitors. The Yperwatch is mounted in a wristwatch and the Gamcard in a case of the size of a standard credit card. The technology provides users with all the performance of a standard professional electronic dosemeter (integrated dose, dose rate, audible alarms, time in use). Yperwatch and Gamcard are based on well-proven electronic dosimetry technology, but with a greater ease of use. (author)

  13. Individual monitoring and its quality assurance using thermoluminescent CaSO[sub 4]:Dy Teflon tape dosemeters in India

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, J.S.; Popli, K.L.; Varadharajan, G.; Kher, R.K.; Venkataraman, G. (Bhabha Atomic Research Centre, Bombay (India). Div. of Radiological Protection)

    1994-01-01

    CaSO[sub 4]:Dy Teflon thermoluminscence dosemeters have been fabricated indigenously in continuous tape form. TL response of the tape dosemeters to [beta] and [gamma] radiations has been studied as a function of the dosemeter thickness to arrive at its optimum value. A single 80 mg.cm[sup -2] thick tape dosemeter (51 mm x 17 mm) along with a mica strip replaces the earlier use of three 200 mg.cm[sup -2] thick disc dosemeters for routine individual monitoring. The tape cards have been in field use for two and half years. The performance characteristics of the cards under laboratory and field conditions are discussed. Dose computation algorithms have been developed to give whole-body dose (mGy) and skin dose (mGy)for photons and [beta] radiation respectively from the TL outputs of three dosimetric elements under 1000 mg.cm[sup -2] Cu + Al composite filter, 180 mg.cm[sup -2] Perspex and an open region in a cardholder. Results of the Quality Assurance Programme, covering various TL monitoring stations in India, are also presented. Based on ANSI criteria, only one outlier was observed over the past seven years. (Author).

  14. La industria minera en México: patrones de desempeño y determinantes de eficiencia

    Directory of Open Access Journals (Sweden)

    Edgar David Gaytán

    2014-01-01

    Full Text Available El propósito del presente artículo es cuantificar y analizar los niveles de eficiencia técnica en la minería no petrolera de México. Se emplea el análisis envolvente de datos (DEA y un modelo econométrico de panel que explora las determinantes de la eficiencia en la operación minera, considerando variables características de la Teoría Económica Regional. Los resultados muestran la consistencia de los patrones de localización, espe¬cialización e infraestructura productiva como factores explicativos de la eficiencia; asimismo, estos constituyen un referente que explica los factores puntuales a mejorar para elevar los niveles de eficiencia en el aprovechamiento de los diferentes minerales estudiados.

  15. La industria minera en México: patrones de desempeño y determinantes de eficiencia

    Directory of Open Access Journals (Sweden)

    Edgar Gaytán

    2014-01-01

    Full Text Available El propósito del presente artículo es cuantificar y analizar los niveles de eficiencia técnica en la minería no petrolera de México. Se emplea el análisis envolvente de datos (DEA y un modelo econométrico de panel que explora las determinantes de la eficiencia en la operación minera, considerando variables características de la Teoría Económica Regional. Los resultados muestran la consistencia de los patrones de localización, especialización e infraestructura productiva como factores explicativos de la eficiencia; asimismo, estos constituyen un referente que explica los factores puntuales a mejorar para elevar los niveles de eficiencia en el aprovechamiento de los diferentes minerales estudiados.

  16. Evaluations of absorbed dose ratio factor of Al2O3 dosemeter in radiotherapy photon beams using cavity theory

    International Nuclear Information System (INIS)

    Zhu, J.; Chen, S.; Chen, L.; Liu, X.

    2012-01-01

    The aim of the work was to evaluate the absorbed dose ratio factor f md of an Al 2 O 3 dosemeter to water in photon radiotherapy beams using cavity theory. Burlin theory was used for calculating of this ratio. The effective mass attenuation coefficient β was obtained by comparing Monte Carlo simulations in monoenergetic photon beams. The evaluations of the absorbed dose ratio factor f md were studied for Al 2 O 3 dosemeters of different sizes, which were placed at various depths of the water phantom in different radiation field sizes of Mohan's 6, 10 and 15-MV X-rays. Beyond the build-up region, the variation of f md increases by 0.25 % as the depth increases from 4 to 10 cm. The maximum variation due to different dosemeter sizes is 8.3 %. The difference in the f md due to different radiation field sizes is 1.5 %. The effect of the dosemeter size cannot be neglected. The difference in the f md due to the radiation field sizes of different beams would increase as the dosemeter size increases. (authors)

  17. Deviations outside the acceptance limits in the IAEA/WHO TLD audits for radiotherapy hospitals

    International Nuclear Information System (INIS)

    Vatnitsky, S.; Izewska, J.

    2002-01-01

    The main purpose of the IAEA/WHO TLD postal dose audit programme for dosimetry in radiotherapy is to provide an independent verification of the dose delivered by treatment machines in radiotherapy hospitals. The results of the TLD audit are considered acceptable if the relative deviation between the participant's stated dose and the TLD determined dose is within ±5%. The goal of this note is to draw the attention of participants of the TLD programme to some of the common reasons for deviations outside the acceptance limits. Armed with this knowledge, other participants may avoid similar problems in the future. The analysis of deviations presented here is based on the results of TLD audits of the calibration of approximately 1000 Co-60 beams and 600 high-energy X-ray beams performed in the period 1996-2001. A total of 259 deviations outside the ±5% limits have been detected, including 204 deviations for Co-60 beams (20% of all Co-60 beams checked) and 55 for high-energy X-ray beams (10% of all X-ray beams checked). It is worth mentioning that the percentage of large deviations (beyond 10%) is also higher for Co-60 beams than for high-energy X-ray beams. Some problems may be caused by obsolete dosimetry equipment or poor treatment machine conditions. Other problems may be due to insufficient training of staff working in radiotherapy. The clinical relevance of severe TLD deviations detected in the audit programme was confirmed in many cases, but, fortunately, not all-poor dosimetric results reflect deficiencies in the calibration of clinical beams or machine faults. Sometime it happens, that the TLDs are irradiated with an incorrect dose due to misunderstanding of the instructions on how to perform the TLD irradiation. Such dosimetry errors would have no direct impact on actual dose delivered to a patient

  18. Análisis de eficiencia hospitalaria en Chile

    Directory of Open Access Journals (Sweden)

    Planck Barahona-Urbina

    2011-01-01

    Full Text Available Introducción: La importancia del análisis envolvente de datos (AED radica en poder determinar cuáles de los hospitales regionales presentan un mejor desempeño relativo y cuáles podrían mejorar el uso de los recursos. Objetivos: Analizar, haciendo uso de la técnica no paramétrica de análisis envolvente de datos, la eficiencia técnica hospitalaria en Chile. Diseño: Análisis de tipo no paramétrico. Lugar: Hospitales públicos regionales de Chile. Intervenciones: Aplicación del AED para la evaluación de la eficiencia de los establecimientos de la salud. Materiales: Se utilizó datos para el período comprendido entre 1997 y 2006 de las doce regiones del país más la región Metropolitana (RM, de 190 hospitales públicos de distintos grados de especialización. Se identificó datos de actividad hospitalaria y personal facultativo, esto es, como inputs a médicos, enfermeras, matronas, camas disponibles, y como variable output el egreso hospitalario. Principales medidas de resultados: Eficiencia hospitalaria. Resultados: En el año 1997, las regiones IV, VII, VIII, y IX fueron calificadas como técnicamente eficientes, lo que ha significado que han hecho un adecuado uso de sus recursos. Conclusiones: En diez años de estudio, 1997 a 2006, únicamente en el año 1997 cuatro regiones de Chile fueron eficientes. Los hospitales regionales deberían reducir sus inputs en promedio un 10% para situarse sobre la frontera eficiente. El análisis DEA es una buena herramienta para llevar a cabo mediciones de eficiencia y evaluar resultados de gestión, pues permite conocer aquellas unidades que realizan la mejor asignación de sus recursos en comparación al resto de la muestra.

  19. The former tests realized to a personal neutron dosemeter based on solid nuclear tracks detector

    International Nuclear Information System (INIS)

    Camacho, M.E.; Tavera, L.; Balcazar, M.

    1997-01-01

    Due to the increase in the use of neutron radiation a personal neutron dosemeter based on solid nuclear tracks detector (DSTN) was designed and constructed. The personal dosemeter design consists of three arrangements. The first one consists of a plastic nuclear tracks detector (LR115 or CR39) in contact with a LiF pellet. The second one is the same that above but it placed among two cadmium pellets and, the third one is formed by the alone detector without converter neither neutron absorber. The three arrangements are placed inside a plastic porta detector hermetically closed to avoid the bottom produced by environmental radon whichever both detectors (LR115 and CR39) are sensitive. In this work the former tests realized to that dosemeter are presented. (Author)

  20. TLD Postal service for quality audits of beams of Co-60 in reference conditions in Cuba

    International Nuclear Information System (INIS)

    Gutierrez L, S.; Walwyn S, G.; Alonso V, G.

    2006-01-01

    Purpose: To describe the methodology and experience of the Secondary Laboratory of Dosimetric Calibration of Cuba in the establishment of the TLD Postal Service for quality audits of beams of Co-60 in reference conditions. Materials and methods: Through the Coordinated Project of Research (Contract 10794) its was bought 200 solid thermoluminescent detectors of LiF: Mg, Ti (TLD-100) in micro bars form with dimensions of 6 x 1 x 1 mm and of the JR 1152F type manufactured in China. All these detectors were identified individually with a serial number on one of its faces, using a graphite fine sheet. Those detectors for its irradiation are introduced in cylindrical plastic capsules developed and used by the International Atomic Energy Agency (IAEA) in the Audit Postal Service of Dose IAEA/WHO, the capsules have one cavity equal to 3 mm for that is necessary to recover this cavity with a fine plastic tube so that the detectors remain immobile during the irradiation. The method used to determine the individual sensitivity of the thermoluminescent detectors is: to irradiate a detectors group (100 micro bars) 4 times in those same geometric conditions, with the same irradiation history and reading, then it is determine for each detector a sensitivity factor equal to the average of those readings obtained for the 4 irradiation cycles for each i detector among the average of all the reading values obtained during the 4 cycles. The thermoluminescent signal is obtained with a Harshaw 2000C/B reader manual. Results: The satisfactory results obtained in the verification of the calibration of the TLD system, using the reference irradiation service of the Seibersdorf Dosimetry Laboratory of the IAEA in three different years are shown. The results of the audits carried out to the different radiotherapy services of the country in different years are also presented. Conclusions: The experience with the detectors acquired in the project demonstrates that with an appropriate

  1. Electronic stability and reproducible accuracy of HARSHAW 2000(A,B) TLD-analyzer

    International Nuclear Information System (INIS)

    Yossef, S.K.; Henaish, B.A.

    1985-01-01

    Nowadays, the thermoluminescence techniques utilizing natural materials and assorted chemical compound of various geometrical configurations are widely and popularly used on the international scale as a dose evaluation system. The main problems which are usually encounting the accuracy of the evaluated dose by means of such various dosimeter forms are the long and short term stability of the measuring system. Also this manuscript is a very essential details stated out the principle mechanisms which cause that produced TL-readers instability. As it is stated out through the different sections of this issue, it is mainly due to the interior mechanisms of the TLD measuring systems. Further more, the various detailed discussions availed through the different sections of such issue are mainly accompanied by long term experiences gained by the authors. A novel heating cycle mechanism applied to HARSHOW 2000(A and b) TLD analyzer is tested experimentally. Also long and short term stability beside the reproducibility of the TLD reader system were experimentally tested under various seasonable environmental thermal conditions. The results of experimental measurements were noted for a total duration of six months during continuous operation of the TLD reader for one year. 1 fig., 3 tab

  2. La eficiencia: un valor cultural que necesitamos

    Directory of Open Access Journals (Sweden)

    Mauricio Diagama Durán

    2015-05-01

    Full Text Available RESUMEN La eficiencia es un valor social que tanto este, como el modo alcanzado, constituyen problemas culturales que debemos resolver, no solo para manejar el estado, sino también para modernizar nuestra sociedad y hacer competitivas a nuestras organizaciones  y empresas.

  3. Eficiencia técnica y convergencia en los sectores productivos regionales

    Directory of Open Access Journals (Sweden)

    Ma. Jesús Delgado Rodríguez

    2003-01-01

    Full Text Available El objetivo de este trabajo es analizar la evolución y el grado de convergencia en eficiencia técnica de los sectores productivos regionales. Con esta finalidad se construyen índices de productividad de Malmquist, calculados mediante técnicas no paramétricas de programación lineal, que permiten comparar la aportación al crecimiento de la productividad de las ganancias de eficiencia en cada sector. A continuación se ha tratado de determinar si se ha producido un proceso de catching-up tecnológico y si las infraestructuras han constituido un factor condicionante de este. Los resultados muestran diferencias sectoriales en el comportamiento del cambio técnico y del cambio en eficiencia. Se ha confirmado también que los sectores productivos regionales menos eficientes se han beneficiado de la rápida difusión de la tecnología durante el periodo estudiado.

  4. Personal radiation monitoring and assessment of doses received by radiation workers (1996)

    International Nuclear Information System (INIS)

    Morris, N.D.

    1996-12-01

    Since late 1986, all persons monitored by the Australian Radiation Laboratory have been registered on a data base which maintains records of the doses received by each individual wearer. At present, the Service regularly monitors approximately 30,000 persons, which is roughly 90 percent of those monitored in Australia, and maintains dose histories of over 75,000 people. The skin dose for occupationally exposed workers can be measured by using one of the five types of monitor issued by the Service: Thermoluminescent Dosemeter (TLD monitor), Finger TLD 3, Neutron Monitor, Special TLD and Environmental monitor. The technical description of the monitors is provided along with the method for calculating the radiation dose. 5 refs., 7 tabs., 5 figs

  5. Use of active dosemeters as a optimization tool in hemodynamics

    International Nuclear Information System (INIS)

    Nunes, Rafael; Pereira, Dirceu D.; Rodrigues, Barbara B.D.; Ferreira, Esmeralci

    2016-01-01

    Interventional cardiology procedures are, in general, associated with high doses in patients and professionals. The objective of this study is to measure the radiation levels received by professionals .The professional dosimetry was performed in a department of Hemodynamics of University Hospital in Rio de Janeiro. were followed 331 coronary angiography (CA) and 26 percutaneous transluminal coronary angioplasty (PTCA) procedures. For this, were used active dosemeters to measure the radiation levels at the chest of interventional professionals. The results show that average personal equivalent dose of doctors, per procedure was 100 e 154 μSv. On average, nursing technicians and radiologist receive 12 and 10% of doses of physicians, respectively, during CA procedures. From the results, it appears that the doses of hemodynamics exceed the annual dose limit of the standards. The use of lead shielding is presented as an effective action to reduce doses in these workers. (author)

  6. Photon and fast neutron dosimetry using aluminium oxide thermoluminescence dosemeters in a pool-type research reactor

    International Nuclear Information System (INIS)

    Santos, J.P.; Marques, J.G.; Fernandes, A.C.; Osvay, M.

    2007-01-01

    Al 2 O 3 :Mg,Y thermoluminescence (TL) dosemeters were used to measure photon and fast neutron doses in the mixed radiation field of the Portuguese Research Reactor. The dosemeters were irradiated in core positions under a photon dose rate of the order of 10 4 Gy/h and a fast neutron flux in the range of 10 9 -10 11 n/cm 2 /s. In order to evaluate the ability of the TL dosemeters for mixed field dosimetry at the research reactor, the measurements were compared with results obtained via conventional methods. The agreement between the different methods is better than 13% for the determination of photon doses and within 5% for the determination of neutron fluxes in mixed fields

  7. Use of TLD in radiation field studies in different materials

    International Nuclear Information System (INIS)

    Carron, W.; Ghilardi Netto, T.

    1987-01-01

    The dose conversion factor of a thermoluminescent dosemeter of LiF for water, wood and soil is determined. The dose curves in depth relatioship as well as the regression equations are presented. (M.A.C.) [pt

  8. Calibration of TLD cards to beta ray spectra of 32P

    International Nuclear Information System (INIS)

    Ben-Shachar, B.; German, U.; Naim, E.

    1994-01-01

    The results of the evaluation of TLD chips are received in nC, and we need to transform these values to mGy, in order to obtain the penetrating and the non-penetrating dose. The calibration factors were determined experimentally by irradiation the TLD chips with an uranium source. Beta rays having other spectra can cause incorrect values when estimating the non-penetrating dose. If the spectrum of the beta source is known, a specific evaluation of the calibration factor can be performed. In this report, the estimation of the calibration factor for a 32 P source is presented. LiF:Ti,Mg TLD cards were irradiated calibrated source of 90 Sr/ 90 Y and 204 Tl and non-calibrated source of 32 P, in order to find the beta correction factor for the spectrum of 32 P. Calculations of the beta correction factor were performed too, by applying the Loevinger equations to the geometry of the TLD chips used in our routine measurements. The calculated values of the beta correction factors are lower than the experimental ones. When comparing the ratios, between the beta factors of 32 P and 90 Sr/ 90 Y received from the experiments and from the calculation, we found them to be constant up to ±5%. (authors) 15 refs, 2 figs, 6 tabs

  9. Effect of some parameters in the response of the Perspex 3042, Lot L amber dosemeters

    International Nuclear Information System (INIS)

    Prieto M, E.F.; Barrera G, G.

    2004-01-01

    The answer of the dosimetric systems is affected by several factors, for what should know as these factors they influence in each one of the different dosimetric systems and by this way to minimize its effect in the value of the absorbed dose and to obtain exact dose values. One of the dosimetric systems more used in the high dose dosimetry like routine dosemeter for the control of the irradiation process are the Perspex dosemeters, for their speed in the obtaining the information, their easy manipulation and the precision that they present. To this dosemeters group they belong the same as the Red and Clear the Amber, which are adequate for the measurement of the radiation dose in the range of high doses. The objective of the present work is to obtain the calibration curves of the dosemeters Amber Perspex 3042, Lot L under our work conditions, like they are the irradiation temperatures and of storage and to know the influence of the rate dose in the value of the absorbed dose for different measurement wavelengths, as well as, the relationship among the one post-irradiation time and the specific absorbance value induced in function of the absorbed dose. (Author)

  10. A portable versatile x-and γ-ray dosemeter with digital display for medical use

    International Nuclear Information System (INIS)

    Sankaran, A.; Gangadharan, P.

    1980-01-01

    A multipurpose dosemeter based on analogue-to-digital (A-D) conversion has been developed using solid state devices, micropower integrated circuits and displays. The A-D converter combines the features of a MOSFET electrometer, a voltage-to-frequency converter, the automatic Townsend balance, LED(LCD) display for exposure, analogue output and has a voltage-measuring accuracy of +-O.1% FS+-1 digit. The dosemeter which is designed to measure a wide range of X- and γ-ray exposure rates (1 mRh -1 to 1000 R min -1 ) and exposures (1 mR to 1000 R) with a variety of air-equivalent ionisation chambers, is compact, rugged and battery or AC mains powered. It is designed to provide trouble-free performance, easy operation and maintenance and to be independent of climatic conditions. Combining the features of a survey meter, dosemeter and a radioisotope calibrator, it can be fabricated using the facilities locally available in hospitals or universities. (author)

  11. Viability of the Fricke dosemeter doped with methylene blue

    International Nuclear Information System (INIS)

    Souza, V.L.B.; Santos, C.D.A.; Rodrigues, K.R.G.; Cunha, M.S.; Figueiredo, M.D.C.; Melo, R.T.

    2009-01-01

    This work aims to find the possible utilization of the Fricke dosemeter doped with methylene blue (FMB) for the dosimetry of photodynamic therapy. The FMB was irradiated wit X rays and light emitted diodes demonstrating positive answers to the stimulus, being probably to be used for dosimetric objectives

  12. Exposure levels to radiation in a nuclear medicine laboratory: measurements with thermoluminescence dosemeters

    International Nuclear Information System (INIS)

    Ruiz J, A.

    2000-01-01

    Since 1996 in the Nuclear medicine Department and another routine and research departments of the National Institute of Medical and Nutrition Sciences (INCMNSZ) are working at least with 12 radioactive sources opened and sealed. However, it was unknown if with the Tl personal dosemeters with lithium fluoride crystals (LiF), could be possible to receive information about the equivalent dose for each radionuclide or if there was some radionuclide that by being low energy emissor or beta energy emissor, it did not represent an ionization power sufficient to excite the crystals of the thermoluminescent dosemeters (DTL). In this work the obtained results with control dosemeters of diverse source opened or sealed are shown, which were put at 1 cm of the LiF crystals during a time exposure 18 hours. Therefore the objective of this work is to verify which sources excite or not to DTL crystals and taking the pertinent safety measures for each radionuclide. The conclusion is that the majority of dosemeters were excited by beta or gamma radiation of the radionuclides and that LiF crystals are able to receive equivalent doses until 1200 mSv, being this a guarantee for the staff, that in an any moment could be exposed to high dose in his working day. Also it was corroborated that the radionuclides more energizer are: iodine-131, iodine-125 and sodium-22 while the phosphorus-32 must be managed with careful, since the exposure to hands can result significant, just like the technetium-99m ( 99m Tc). (Author)

  13. Dose distribution and risk factors in tele cobalt therapy and intracavitary treatment with sealed sources of Cesium-137

    International Nuclear Information System (INIS)

    Briquet, C.

    1984-01-01

    The purpose of this work is to evaluate dose to organs, outside the treatment volume. The experimental measurements were done using TLD dosemeters, placed in various regions of a Rando Alderson Phantom. The theoretical absorbed doses were calculated using the Monte Carlo method applied to a mathematical phantom. (author)

  14. The measurement of patient doses from diagnostic x-rays

    International Nuclear Information System (INIS)

    Morris, N.D.; Solomon, S.B.

    1980-06-01

    As part of the National Health and Medical Research Council survey to determine the genetic and mean bone-marrow doses to the Australian population from the medical, dental and chiropractic uses of radiation sources, doses to patients undergoing X-ray diagnostic procedures were evaluated. The doses were measured using capsules of LiF or CaF 2 :Dy thermoluminescent dosemeters (TLD). The evaluation of the TLD measurements is described and the mean values of the skin doses for patients undergoing various radiographic examinations in Australia in 1970 are presented

  15. Criterios de eficiencia para la evaluación de explotaciones agropecuarias

    Directory of Open Access Journals (Sweden)

    Prieto Delgado Germán Octavio

    1986-12-01

    Full Text Available

    Con miras a evaluar el impacto de una política agraria es útil calibrar el desempeño de los productores, y el concepto de eficiencia económica provee una base teórica para tal propósito. Esto no significa que únicamente sean las variables económicas las que expliquen la eficiencia, pero aquellas constituyen un punto de partida que puede complementarse con variables no económicas para llevar a cabo una evaluación más comprensiva.

  16. Unusual ratio of TL readouts of different discs of personnel monitoring TLD badge based on CaSO4: Dy teflon disc

    International Nuclear Information System (INIS)

    Pradhan, S.M.; Ande, C.D.; Kher, R.K.; Chourasiya, G.; Vashishtha, R.; Gupta, A.K.

    2005-01-01

    In India Personnel Monitoring against external radiation hazard of gamma, beta and X-rays is provided using a TLD badge based on CaSO 4 : Dy Teflon TLD disc. Unusual ratios of TL readouts of different discs of TLD badge (Disc Ratios) observed for service TLD badges of radiation workers were investigated and simulated. Simulations were carried out by exposure of TLD badges by speck type radioactive sources placed in contact of badges, exposure of TLD badges placed on concrete floor to a radiography source. Clues for the simulation were obtained from nature of work, radiological conditions during course of individuals' work whose TLD badges showed the unusual disc ratios and geometrical calculations performed. It is concluded that although the actual exposure condition during use is unknown, the unusual disk ratios observed for the service TLD badges can be simulated and utilized to arrive at probable exposure conditions. The study helped in investigations of the abnormal exposures and assigning doses to the concerned radiation workers. (author)

  17. Análisis de eficiencia relativa de hospitales públicos de Costa Rica.

    Directory of Open Access Journals (Sweden)

    Melvin Morera-Salas

    2015-01-01

    Full Text Available El análisis de eficiencia relativa hospitalaria resulta un tema trascendental para la Caja Costarricense de Seguro Social, dado que le permite determinar cuáles de los hospitales presentan un mejor desempeño relativo y cuáles podrían mejorar el uso de los recursos. El objetivo es analizar la eficiencia técnica hospitalaria en Costa Rica. Se utilizaron datos del 2012-2013 para los hospitales generales de la Caja Costarricense de Seguro Social. Para determinar la eficiencia hospitalaria se utiliza el análisis envolvente de datos con dos insumos: gasto en hospitalización y las camas y tres productos: actividad hospitalaria ajustada por casuística, índice de funcionamiento e índice de mortalidad intrahospitalaria ajustada por riesgo. Los resultados muestran que el nivel de eficiencia varía sustancialmente entre los 23 hospitales analizados. En 2013, un 30% de los hospitales resultó ser eficiente técnicamente, situación que mejoró levente respecto a 2012. Este trabajo es una primera aproximación del análisis de eficiencia de los hospitales públicos de Costa Rica. Se realizó un esfuerzo para homogenizar los datos, al ajustar las variables para considerar la complejidad y el riesgo de los casos que maneja cada hospital, de tal forma que los resultados sean comparables entre centros de diferentes tamaño y complejidad. Como conclusión se tiene que el 70% de los hospitales puede mejorar el uso de los recursos.

  18. Análisis de eficiencia relativa de hospitales públicos de Costa Rica

    Directory of Open Access Journals (Sweden)

    Melvin Morera-Salas

    2015-01-01

    Full Text Available El análisis de eficiencia relativa hospitalaria resulta un tema trascendental para la Caja Costarricense de Seguro Social, dado que le permite determinar cuáles de los hospitales presentan un mejor desempeño relativo y cuáles podrían mejorar el uso de los recursos. El objetivo es analizar la eficiencia técnica hospitalaria en Costa Rica. Se utilizaron datos del 2012-2013 para los hospitales generales de la Caja Costarricense de Seguro Social. Para determinar la eficiencia hospitalaria se utiliza el análisis envolvente de datos con dos insumos: gasto en hospitalización y las camas y tres productos: actividad hospitalaria ajustada por casuística, índice de funcionamiento e índice de mortalidad intrahospitalaria ajustada por riesgo. Los resultados muestran que el nivel de eficiencia varía sustancialmente entre los 23 hospitales analizados. En 2013, un 30% de los hospitales resultó ser eficiente técnicamente, situación que mejoró levente respecto a 2012. Este trabajo es una primera aproximación del análisis de eficiencia de los hospitales públicos de Costa Rica. Se realizó un esfuerzo para homogenizar los datos, al ajustar las variables para considerar la complejidad y el riesgo de los casos que maneja cada hospital, de tal forma que los resultados sean comparables entre centros de diferentes tamaño y complejidad. Como conclusión se tiene que el 70% de los hospitales puede mejorar el uso de los recursos.

  19. Medidas de eficiencia productiva utilizadas en las compañías de transporte aéreo y alguna evidencia con relación a los cambios observados en dicha eficiencia

    Directory of Open Access Journals (Sweden)

    John Jairo García Rendón

    2006-10-01

    Full Text Available Este articulo describe cuales han sido las diferentes formas de medir la eficiencia productiva en los medios de transporte aereo, fundamentalmente los de Estados Unidos y los Europeas, aunque marginalmente, se hace alusion a nivel mundial, y ademas trata de mostrar a partir de algunos estudios realizados, cual ha sido la evidencia y el efecto de la desregulacion de estas industrias en cuanto a la eficiencia productiva

  20. Study of a selection of 10 historical types of dosemeter: variation of the response to Hp(10) with photon energy and geometry of exposure.

    Science.gov (United States)

    Thierry-Chef, I; Pernicka, F; Marshall, M; Cardis, E; Andreo, P

    2002-01-01

    An international collaborative study of cancer risk among workers in the nuclear industry is tinder way to estimate direetly the cancer risk following protracted low-dose exposure to ionising radiation. An essential aspect of this study is the characterisation and quantification of errors in available dose estimates. One major source of errors is dosemeter response in workplace exposure conditions. Little information is available on energy and geometry response for most of the 124 different dosemeters used historically in participating facilities. Experiments were therefore set up to assess this. using 10 dosemeter types representative of those used over time. Results show that the largest errors were associated with the response of early dosemeters to low-energy photon radiation. Good response was found with modern dosemeters. even at low energy. These results are being used to estimate errors in the response for each dosemeter type, used in the participating facilities, so that these can be taken into account in the estimates of cancer risk.

  1. Experience of TLD personnel monitoring laboratory

    International Nuclear Information System (INIS)

    Jakhete, Prashant

    2002-01-01

    Full text: Renentech Laboratories is the first Private Enterprise in India to have been chosen to provide Personnel radiation monitoring services to radiation workers at different parts of the country. Since 1992 the Company has been manufacturing TLD phosphor powder of requisite quality and from 1995 commenced the production of TLD cards for radiation monitoring. After getting the necessary approval from the competent authorities in the country, the company undertook a rigorous quality assurance programme and received the accreditation in 1999 to carry out the personnel monitoring of radiation. Since then the trained staff of the Company is covering 1200 institutions in 16 states where radiation is being used. This translates to processing of 60,000 Till cards annually, the maximum limit permitted by BARC. Processing of exposure data is done strictly according well-laid guidelines. Any cases of overexposure are immediately referred to Calibration and Dose Record Section of BARC to meet the regulatory requirements. Necessary procedural guidelines are followed to handle such cases. In this lecture, learning, operation and implementation experience of a typical Private Company in a task, which, hitherto had been regarded as exclusive responsibility of state owned institution, is enumerated

  2. NRC TLD Direct Radiation Monitoring Network

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1992-06-01

    The US Nuclear Regulatory Commission (NRC) Direct Radiation Monitoring Network is operated by the NRC in cooperation with participating states to provide continuous measurement of the ambient radiation levels around licensed NRC facilities, primarily power reactors. Ambient radiation levels result from naturally occurring radionuclides present in the soil, cosmic radiation constantly bombarding the earth from outer space, and the contribution, if any, from the monitored facilities and other man-made sources. The Network is intended to measure radiation levels during routine facility operations and to establish background radiation levels used to assess the radiological impact of an unusual condition, such as an accident. This report presents the radiation levels measured around all facilities in the Network for the first quarter of 1992. All radiation measurements are made using small, passive detectors called thermoluminescent dosimeters (TLDs), which provide a quantitative measurement of the radiation levels in the area in which they are placed. Each site is monitored by arranging approximately 40 to 50 TLD stations in two concentric rings extending to about five miles from the facility. All TLD stations are outside the site boundary of the facility

  3. Thermoluminescent dosemeters characterization for patient dosimetry in diagnostic radiology preliminary results

    International Nuclear Information System (INIS)

    Castro, William J.; Squair, Peterson L.; Gonzaga, Natalia B.; Nogueira, Maria S.; Silva, Teogenes A. da

    2009-01-01

    The determination of the metrological characteristics of thermoluminescent (TL) dosimeters plays an important role in dosimetry of patients submitted to x-ray examinations for diagnostic purpose. Entrance surface doses can be measured with TL dosimeters to verify the compliance with the diagnostic reference levels. Organ doses can be estimated through TL measurements in an anthropomorphic phantom which it allows the radiation risk assessment. In this work, LiF:Mg,Ti (TLD-100) rod and chip thermoluminescent dosimeters were characterized considering their use for patient dosimetry in computerized tomography and mammography. Preliminary results showed that TL dosimeters have a response reproducibility of 7.8% and 4.8% and homogeneity of 18.4% and 6.5% for rod and chip shapes, respectively. (author)

  4. Characterization of a two-component thermoluminescent albedo dosemeter according to ISO 21909

    Energy Technology Data Exchange (ETDEWEB)

    Martins, M.M., E-mail: marcelo@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN), Av. Salvador Allende s/n, CEP 22780-160, Rio de Janeiro, RJ (Brazil); Mauricio, C.L.P., E-mail: claudia@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN), Av. Salvador Allende s/n, CEP 22780-160, Rio de Janeiro, RJ (Brazil); Pereira, W.W., E-mail: walsan@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN), Av. Salvador Allende s/n, CEP 22780-160, Rio de Janeiro, RJ (Brazil); Silva, A.X. da, E-mail: ademir@con.ufrj.b [Coordenacao dos Programas de Pos-Graduacao em Engenharia, COPPE/PEN Caixa Postal 68509, CEP 21941-972, Rio de Janeiro, RJ (Brazil)

    2011-05-15

    A two-component thermoluminescent albedo neutron monitoring system was developed at Instituto de Radioprotecao e Dosimetria, Brazil. As there is no Brazilian regulation for neutron individual monitoring service, the system was tested according to the ISO 21909 standard. This standard provides performance and test requirements for determining the acceptability of personal neutron dosemeters to be used for the measurement of personal dose equivalent, H{sub p}(10), in neutron fields with energies ranging from thermal to 20 MeV. Up to 40 dosemeters were used in order to accomplish satisfactorily the requirements of some tests. Despite operational difficulties, this albedo system passed all ISO 21909 performance requirements. The results and problems throughout this characterization are discussed in this paper.

  5. Study on routines and procedures of calibration of clinical dosemeter on gamma radiation beams at the IPEN-CNEN/SP, Brazil

    International Nuclear Information System (INIS)

    Damatto, Willian B.; Potiens, Maria da Penha A.; Santos, Gelson P.; Vivolo, Vitor

    2009-01-01

    The calibration consists in the comparison of the equipment to be calibrated with other equipment already calibrated by another standard, which means the equipment that will accomplish shall be considered secondary or tertiary, depending on the calibration that will be accomplished. As the clinical dosemeters are used for quality control services in the hospitals, these dosemeters need a reliable measurement precision. Therefore, this work intends to demonstrate the importance of the clinical dosemeter and the calibration, requiring special care face to all clinical set

  6. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO4: Dy + Ptfe

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin N, J.; Perez P, M.A.; Castillo H, M.; Flores F, F.; Guzman R, L.V.

    1999-01-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO 4 : Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  7. Calibration of a special neutron dosemeter based on solid-state track detectors and fission radiators in various neutron fields

    International Nuclear Information System (INIS)

    Doerschel, B.; Krusche, M.; Schuricht, V.

    1980-01-01

    The calibration of a personnel neutron dosemeter in different neutron fields is described. The badge-like dosemeter contains 5 detectors: polycarbonate foil (10 μm, Makrofol KG), 232 Th, natural uranium, natural uranium with boron, and natural uranium with cadmium. Detector sensitivity and calibration factors have been calculated and measured in radiation fields of 252 Cf fission neutrons, WWR-S reactor neutrons with and without Cd and Fe shielding, 3-MeV (d,t) generator neutrons, and 238 PuBe neutrons. Measurement range and achievable accuracy are discussed from the point of view of applying the dosemeter in routine and emergency uses

  8. Graphite mixed magnesium borate TL dosemeters for beta ray dosimetry

    DEFF Research Database (Denmark)

    Prokic, M; Christensen, Poul

    1984-01-01

    Sintered MgB4O7:Dy dosemeters with graphite contents from 1 to 10% were investigated for application for personnel dosimetry. Data are given on dose response, dose threshold, reproducibility, beta energy response and fading. Furthermore, results from practical field experiments are presented...

  9. Medidas de mejora de la eficiencia energética de edificios residenciales

    OpenAIRE

    Hernández Sánchez, Juan Manuel

    2012-01-01

    El parque de edificios residenciales existente tiene un potencial muy grande para mejorar la eficiencia energética a corto y medio plazo, debido al gran número de viviendas existentes y a su larga vida residual. Los factores que influyen directamente en el consumo energético y en las emisiones asociadas a los edificios residenciales son: la envolvente térmica, la eficiencia energética de los equipos, las fuentes energéticas utilizadas y el comportamiento de los usuarios. Las barreras qu...

  10. The study of new calibration features in the Harshaw TLD system

    International Nuclear Information System (INIS)

    Luo, L.Z.

    2005-01-01

    Full text: In the Harshaw TLD system, there are three key calibration procedures; the reader, the dosimeter and the algorithm. These procedures must be properly calibrated for the system to achieve the optimum results. For the conventional reader and dosimeter calibration, Harshaw recommends a pre-fade and a post-fade of 24 - 48 hours when calibrating the system. Harshaw also emphasizes that keeping the fade time consistent is important to maintain the quality of the system performance. In recent years, new calibration features have been introduced into the operating system. These new features are auto calibration, auto QC and auto blank, and they give the user the ability to set up the clear-expose-read performed automatically in a sequence for each dosimeter. This saves processing time and keeps the fade time the same. However, since the fade time is near zero, will it affect the TLD system calibration factors? What should the user expect? This paper presents a study of the effect of auto calibration / auto QC to the TLD operation. (author)

  11. Environmental monitoring with TLD in Costa Rica

    International Nuclear Information System (INIS)

    Mora, P.; Mora, E.

    2003-01-01

    Using thermoluminescent dosimeters (Harshaw TLD-200) the first set of costarican data on absorbed doses in air from natural radiation is obtained. During the period from September 1996 to october 2000 eight different sites throughout the country were chosen to instal the TLD stations. Each station had eight cards (five were changed every three months and three changed annually). The dosimeters were read in the Applied Nuclear Physics Laboratory using a 4000 Harshaw reader and with the help a mathematical algorithm and the equipment calibration factors the dose rate in air (nGy h -1 ) was calculated. The national average is 108.9 ± 32.4 nGy h -1 , the lowest values (in nGy h -1 ) were obtain at sea level at Quebrada Honda with 53 ± 11 and the highest values (in nGy h -1 ) at Cartago with 160 ± 19. A slight increase with altitude is observed even though the Cartago station was always the highest. The values found agree with reported worldwide values for environmental doses in air. (Author) [es

  12. Systematic errors in the readings of track etch neutron dosemeters caused by the energy dependence of response

    International Nuclear Information System (INIS)

    Tanner, R.J.; Thomas, D.J.; Bartlett, D.T.; Horwood, N.

    1999-01-01

    A study has been performed to assess the extent to which variations in the energy dependence of response of neutron personal dosemeters can cause systematic errors in readings obtained in workplace fields. This involved a detailed determination of the response functions of personal dosemeters used in the UK. These response functions were folded with workplace spectra to ascertain the under- or over-response in workplace fields

  13. Systematic errors in the readings of track etch neutron dosemeters caused by the energy dependence of response

    CERN Document Server

    Tanner, R J; Bartlett, D T; Horwood, N

    1999-01-01

    A study has been performed to assess the extent to which variations in the energy dependence of response of neutron personal dosemeters can cause systematic errors in readings obtained in workplace fields. This involved a detailed determination of the response functions of personal dosemeters used in the UK. These response functions were folded with workplace spectra to ascertain the under- or over-response in workplace fields.

  14. Use of a robotic manipulator in the simulation of the automation of a calibration process of dosemeters

    International Nuclear Information System (INIS)

    Benitez R, J.S.; Najera H, M.C.

    2002-01-01

    The development of a system based in a manipulative robot which simulates the operative sequence in a calibration process of dosemeters is presented. In this process it is performed the monitoring of the dosemeter positions and the calibrator by mean of an arm of articulated robot which develops the movement sequences and the taking a decision based on the information coming from the external sensors. (Author)

  15. Improvements of RGD3 TLD reader

    International Nuclear Information System (INIS)

    Zhao Jianxing; Wang Jiaqi; Li Yuanfang; Wu Furong; Xiao Wuyun

    1999-01-01

    The author summarized the main features of the improved RGD3 TLD reader. Through a large number of experiments some persuasive data are obtained, which show that an remarkable improvement has been achieved, especially in its stability to the standard illuminates, data dispersivity, and effectiveness to glow curves analysis. Working with the newly developed data processing software, the comprehensive performance of the whole system will be enhanced greatly

  16. Skin dose assessment in routine personnel beta/gamma dosimetry

    International Nuclear Information System (INIS)

    Christensen, P.

    1980-01-01

    Three alternative methods are outlined by which substantial improvements of the capabilities of existing routine monitoring systems for skin dose assessment can be obtained. The introduction of a supplementary skin dosemeter may be an attractive method for systems with badges that have a capability for an additional dosemeter already built-in. The two-side reading method has limited possibilities because of reduced accuracy for mixed radiation and technical difficulties in using it for TLD systems with planchet heating. The use of a boron diffused LiF layer for skin dose assessment seems to be most attractive method since the only modification needed here is replacement of a dosemeter. However the study of this method is so far only in a preliminary stage and further investigations are needed. (U.K.)

  17. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO{sub 4}: Dy + Ptfe; Intercomparacion dosimetrica en unidades de cobalto 60 usando cristales de TLD-100 y CaSO{sub 4}: Dy + PTFE

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E. [Universidad Autonoma Metropolitana Xochimilco, Mexico D.F. (Mexico); Azorin N, J. [Universidad Autonoma Metropolitana Iztapalapa, Mexico D.F. (Mexico); Perez P, M.A. [Instituto Nacional de Cancerologia, Mexico D.F. (Mexico); Castillo H, M. [Centro Medico Nacional 20 de Noviembre, ISSSTE, Mexico D.F. (Mexico); Flores F, F. [Unidad de Oncologia, Centro Medico Nacional, IMSS, Mexico D.F. (Mexico); Guzman R, L.V. [Unidad de Oncologia, Hospital General de Mexico, Mexico D.F. (Mexico)

    1999-07-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO{sub 4}: Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  18. Skin dose measurements using MOSFET and TLD for head and neck patients treated with tomotherapy

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A.; Murthy, Vedang; Goel, Vineeta; Tambe, Chandrashekar M.; Dhote, Dipak S.; Deshpande, Deepak D.

    2009-01-01

    The purpose of this work was to estimate skin dose for the patients treated with tomotherapy using metal oxide semiconductor field-effect transistors (MOSFETs) and thermoluminescent dosimeters (TLDs). In vivo measurements were performed for two head and neck patients treated with tomotherapy and compared to TLD measurements. The measurements were subsequently carried out for five days to estimate the inter-fraction deviations in MOSFET measurements. The variation between skin dose measured with MOSFET and TLD for first patient was 2.2%. Similarly, the variation of 2.3% was observed between skin dose measured with MOSFET and TLD for second patient. The tomotherapy treatment planning system overestimated the skin dose as much as by 10-12% when compared to both MOSFET and TLD. However, the MOSFET measured patient skin doses also had good reproducibility, with inter-fraction deviations ranging from 1% to 1.4%. MOSFETs may be used as a viable dosimeter for measuring skin dose in areas where the treatment planning system may not be accurate.

  19. Skin dose measurements using MOSFET and TLD for head and neck patients treated with tomotherapy.

    Science.gov (United States)

    Kinhikar, Rajesh A; Murthy, Vedang; Goel, Vineeta; Tambe, Chandrashekar M; Dhote, Dipak S; Deshpande, Deepak D

    2009-09-01

    The purpose of this work was to estimate skin dose for the patients treated with tomotherapy using metal oxide semiconductor field-effect transistors (MOSFETs) and thermoluminescent dosimeters (TLDs). In vivo measurements were performed for two head and neck patients treated with tomotherapy and compared to TLD measurements. The measurements were subsequently carried out for five days to estimate the inter-fraction deviations in MOSFET measurements. The variation between skin dose measured with MOSFET and TLD for first patient was 2.2%. Similarly, the variation of 2.3% was observed between skin dose measured with MOSFET and TLD for second patient. The tomotherapy treatment planning system overestimated the skin dose as much as by 10-12% when compared to both MOSFET and TLD. However, the MOSFET measured patient skin doses also had good reproducibility, with inter-fraction deviations ranging from 1% to 1.4%. MOSFETs may be used as a viable dosimeter for measuring skin dose in areas where the treatment planning system may not be accurate.

  20. Influence of the PMMA and the ISO slab phantom for calibrating personal dosemeters

    International Nuclear Information System (INIS)

    Ginjaume, M.; Ortega, X.; Barbosa, A.

    2000-01-01

    Wide agreement has been achieved among the main Bodies and Organisations involved in standardisation of radiation protection, related to the operational quantities for personal dosimetry. Since their definition in 1985, several reports have been published to clarify and define the experimental set up to be used for the calibration of dosemeters in terms of the above-mentioned quantities. Among these lines, ICRU 47 has listed five different phantoms that are used for calibration and whose results were accurate, within accepted uncertainties. However, to achieve uniformity in calibration procedures, the 30 cm x 30 cm x 15 cm PMMA slab phantom was recommended. The secondary calibration Laboratory from the Institut de Techniques Energetiques at the Technical University of Catalonia (UPC) agreed with the Spanish Nacional Laboratory to adopt the recommended PMMA phantom but to improve the accuracy of the calibration procedure, by introducing a correction factor for backscatter differences in a PMMA and an ICRU slab phantom. Such corrections were of the order of 8% for the low-energy X-ray qualities. Recently, ISO in ISO 4037-3, has proposed the ISO water slab phantom which consists of a 30 cm x 30 cm x 15 cm water phantom with PMMA walls (front wall 2.5 mm thick). This new phantom could be substituted by the above mentioned PMMA phantom for radiation qualities with mean energy equal or above that of 137 Cs. The aim of this work is to compare the influence of both phantoms when calibrating personal dosemeters with photons. A set of four TL personal dosemeters that are used in the UPC personal dosimetry Service and an electronic personal dosemeter (SIEMENS EPD-2) were calibrated in terms of H p (10) and H p (0.07) using the two proposed phantoms. Calibration factors for ISO X-ray narrow spectra, 137 Cs and 60 Co were experimentally obtained for each phantom and compared. In the TL measurements, differences were found to be within TL statistical uncertainty, provided that a

  1. Reasons for deviations outside the acceptance limits in the IAEA/WHO TLD audits for radiotherapy hospitals

    International Nuclear Information System (INIS)

    Vatnitsky, Stanislav; Izewska, Joanna

    2002-01-01

    The main purpose of the IAEA/WHO TLD postal dose audit programme for dosimetry in radiotherapy [1] is to provide an independent verification of the dose delivered by treatment machines in radiotherapy hospitals. The results of the TLD audit are considered acceptable if the relative deviation between the participant's stated dose and the TLD determined dose is within ±5%. The goal of this note is to draw the attention of participants of the TLD programme to some of the common reasons for deviations outside the acceptance limits. Armed with this knowledge, other participants may avoid similar problems in the future. The analysis of deviations presented here is based on the results of TLD audits of the calibration of approximately 1000 Co-60 beams and 600 high-energy X-ray beams performed in the period 1996-2001. A total of 259 deviations outside the ±5% limits have been detected, including 204 deviations for Co-60 beams (20% of all Co-60 beams checked) and 55 for high-energy X-ray beams (10% of all X-ray beams checked). It is worth mentioning that the percentage of large deviations (beyond 10%) is also higher for Co-60 beams than for highenergy X-ray beams. Some problems may be caused by obsolete dosimetry equipment or poor treatment machine conditions. Other problems may be due to insufficient training of staff working in radiotherapy. The clinical relevance of severe TLD deviations detected in the audit programme was confirmed in many cases, but, fortunately, not all-poor dosimetric results reflect deficiencies in the calibration of clinical beams or machine faults. Sometime it happens, that the TLDs are irradiated with an incorrect dose due to misunderstanding of the instructions on how to perform the TLD irradiation. Such dosimetry errors would have no direct impact on actual dose delivered to a patient

  2. Dosimetric evaluation of radiation attenuator glove prototype for containment of radiopharmaceuticals preparation; Evaluation dosimetrique d'un prototype de gant radioattenuateur pour enceintes de preparation des medicaments radiopharmaceutiques

    Energy Technology Data Exchange (ETDEWEB)

    Bouchet, F.; Machefert, N.; Lacoeuille, F.; Le Jeune, J.J.; Couturier, O. [CHU d' Angers, Service de medecine nucleaire, 49 (France); Vannier-Cahouet, A. [CHU d' Angers, Service de pharmacie, 49 (France); Morel, O. [CRLCC Paul-Papin, service de medecine nucleaire, 49 - Angers (France)

    2010-07-01

    The prototype of radio-attenuator glove seems to show an interest in reducing the exposure of the tips for low energy isotopes handling, however these results should be consolidated in order to more accurately estimate the measurement uncertainty of the thermoluminescent dosemeters (T.L.D.) with energy of the isotope. (N.C.)

  3. Use of bubbles dosemeters to measure the neutrons leakage radiations around a medical accelerator

    International Nuclear Information System (INIS)

    Bourgois, L.

    1999-01-01

    In this study, the neutron component has been determined on a medical accelerator (Saturne 43F type accelerator) with the help of bubbles detectors marketed by the Bubble Technology Industry society. BD-PND type dosemeters with sensitivities from 0.1 to 0.23 bubbles/micro sievert have been used. These dosemeters have important advantages: they are small enough and then, homogeneously irradiated, they are insensitive to intense electromagnetic fields and to photons and electrons, they can used several times by compression, the reading of the device does not need expensive means and it is possible to multiply the measure points. (N.C.)

  4. Eficiencia en el uso del agua por las plantas

    Directory of Open Access Journals (Sweden)

    Hipólito Medrano

    2007-01-01

    Full Text Available La disponibilidad de agua es el principal factor limitante de la producción agrícola y ganadera en ambientes de clima mediterráneo. Limitación que, ante las previsiones de Cambio Climático Global realizadas por organismo internacionales, serán mucho mayores en los próximos años. En este escenario, la eficiencia en el uso de los recursos hídricos debe ser un aspecto transversal de las políticas públicas que debe, por tanto, ser afrontado desde diversos puntos de vista. En este sentido, uno de los temas claves a considerar es la eficiencia con la que las plantas usan el agua. El objetivo de este trabajo es hacer una revisión de los diferentes aspectos relacionados con este tema, considerando las diferentes escalas a las que se estudia la eficiencia en el uso del agua por las plantas (EUA, desde la hoja hasta el cultivo o el ecosistema. Así, se abordan las dificultades técnicas que existen para medir, de una forma precisa, la EUA de un cultivo o de un ecosistema, la importancia del ambiente y de las prácticas agronómicas como determinantes de la EUA, la diversidad genética inter e intraespecífica, y las implicaciones prácticas de estos factores a la hora de incrementar la EUA.

  5. Estimation of uncertainty in TLD calibration

    International Nuclear Information System (INIS)

    Hasabelrasoul, H. A.

    2013-07-01

    In this study thermoluminescence dosimeter TLD was use of individual control devices to make sure the quality assurance and quality control in individual monitoring. The uncertainty measured in reader calibration coefficients for tow reader and uncertainty in radiation dose after irradiate in SSDL laboratory. Fifty sample was selected for the study was placed in the oven at a temperature of 400 for an hour to get zero or background and took zero count by or background and took zero count by reader (1) and reader (2) and then irradiate in SSDL by cesium-137 at a dose of 5 mGy and laid back in the oven at degrees 100 and degrees 10 minutes, to 10 chips for calibration and readout count by reader one and reader two. The RCF was found for each reader above 1.47 and 1.11, respectively, and found the uncertainty RCF was found for each reader above 1.47 and 1.11, respectively, and found the uncertainly RCF 0.430629 and 0.431973. Radiation dose was measured for fifty samples irradiate to dose of 5 mGy and read the count by reader 1 and reader 2 the uncertainty was found for each reader 0.490446 and 0.587602.(Author)

  6. La eficiencia de las televisiones públicas en España: la aplicación del DEA como modelo de medición

    Directory of Open Access Journals (Sweden)

    María Soledad Campos Lucena

    2013-01-01

    Full Text Available La eficiencia de la gestión de los recursos públicos, supone unos de los pilares básicos de la economía. El objetivo del presente artículo es medir la eficiencia en el uso de dichos recursos en las televisiones públicas autonómicas en España. Para realizar dicho estudio se utilizó el DEA (Análisis Envolvente de Datos como técnica de análisis, lo que permitió comprobar la eficiencia o ineficiencia de dichas entidades y proponer las medidas de ajuste necesarias para conseguir la eficiencia. A partir de los datos analizados se concluye que no todas las firmas presentan eficiencia técnica y mucho menos eficiencia a escala.

  7. Quality Assurance and Quality Control in TLD Measurement

    International Nuclear Information System (INIS)

    Bhuiyan, S.I.; Qronfla, M.M.; Abulfaraj, W.H.; Kinsara, A.A.; Taha, T.M.; Molla, N.I.; Elmohr, S.M.

    2008-01-01

    TLD technique characterized by high precision and reproducibility of dose measurement is presented by addressing pre-readout annealing, group sorting, dose evaluation, blind tests, internal dose quality audit and external quality control audits. Two hundred and forty TLD chips were annealed for 1 hour at 4000 degree C followed by 2 h at 1000 degree C. After exposure of 1 mGy from 90 Sr irradiator TLDs were subjected to pre-readout annealing at 1000 degree C, then readout, sorted into groups each with nearly equal sensitivity. Upon repeating the procedures, TLDs having response >3.5% from group mean were dropped to assuring group stability. Effect of pre-readout annealing has been studied. Series of repeated measurements were conducted to stabilize calibration procedures and DCF generation using SSDL level 137 Cs calibrator, dose master, ionization chambers. Performed internal dose quality audits, blind tests and validated by external QC tests with King Abdulaziz City of Science and Technology

  8. Characterization of workplaces in interventional radiology using active dosemeters ALARA OD

    International Nuclear Information System (INIS)

    Prlic, I.; Milkovic-Kraus, S.; Mestrovic, T.; Suric-Mihic, M.; Vrtar, M.

    2005-01-01

    Full text: Because of progressive development and extended use of interventional radiology procedures it is highly recommended that all individuals involved in the process should be aware of the potential for both stochastic and deterministic effects due to occupational exposure. Interventional radiology procedures are essentially therapeutic and are performed by various medical specialists, not only by properly educated radiologists. As the procedures are performed in such a manner that certain number of medical staff are always needed near the patient, near the x- ray unit, ensuring 'safe' working environment in such radiation x-ray field geometry is a new challenge to regular radiation protection. In this work we are not primary concerned in relatively high doses delivered to patients undergoing interventional procedures. The patient is rather regarded as a secondary radiation source which emits scattered x-rays. The working staff, moving in mixed, primary and scattered x-ray field, is expected to be exposed to higher occupational doses due to combination of extended fluoroscopy times, elevated fluoroscopy currents and larger amount of radiographic images required. The protection of both patients and staff is to be upgraded. As passive dosemetes will give us clear knowledge only about the monthly integrated occupational dose, a reasonable doubt exists about the frequency and duration, of receiving the dose. Measuring dose rate is not a part of regular passive dosemeters monitoring systems. This is why we have developed active - electronic dosemeter device which provides us with additional dosimetry data about the frequency and duration of professional exposure burden. Digital dosemeter ALARA OD will record and integrate any occupational dose including the normal radiation background in the working area. It will record the time and duration of any fluoroscopic exposure done. This gives us the data about the dose rate of occupational radiation and frequency of

  9. Dosimetry of beta particles using Li:Mg, Cu, P + Ptfe

    International Nuclear Information System (INIS)

    Olvera, L.; Azorin, J.; Rivera, T.

    2003-01-01

    This paper presents the experimental results of determining the thermoluminescence (Tl) response of LiF: Mg, Cu, P + Ptfe pellets excited with 90 Sr/ 90 Y beta radiation. The glow curve exhibited three peaks which appear at 121 C, 178 C and 217 C . Its relative sensitivity is 49 with respect to that of the TLD-100 dosemeter taken as a reference. The minimal dose that could be measured was 750 mGy. The Tl response as a function of dose was linear in the range of 0.7 mGy to 22.5 mGy. The study of the repeatability of the information contained in the pellets showed a standard deviation of 2 %. (Author)

  10. Calibration of PADC-based neutron area dosemeters in the neutron field produced in the treatment room of a medical LINAC

    International Nuclear Information System (INIS)

    Bedogni, R.; Domingo, C.; Esposito, A.; Gentile, A.; García-Fusté, M.J.; San-Pedro, M. de; Tana, L.; D’Errico, F.; Ciolini, R.; Di Fulvio, A.

    2013-01-01

    PADC-based nuclear track detectors have been widely used as convenient ambient dosemeters in many working places. However, due to the large energy dependence of their response in terms of ambient dose equivalent (H ∗ (10)) and to the diversity of workplace fields in terms of energy distribution, the appropriate calibration of these dosemeters is a delicate task. These are among the reasons why ISO has introduced the 12789 Series of Standards, where the simulated workplace neutron fields are introduced and their use to calibrate neutron dosemeters is recommended. This approach was applied in the present work to the UAB PADC-based nuclear track detectors. As a suitable workplace, the treatment room of a 15 MV Varian CLINAC DHX medical accelerator, located in the Ospedale S. Chiara (Pisa), was chosen. Here the neutron spectra in two points of tests (1.5 m and 2 m from the isocenter) were determined with the INFN-LNF Bonner Sphere Spectrometer equipped with Dysprosium activation foils (Dy-BSS), and the values of H ∗ (10) were derived on this basis. The PADC dosemeters were exposed in these points. Their workplace specific H*(10) responses were determined and compared with those previously obtained in different simulated workplace or reference (ISO 8529) neutron fields. - Highlights: ► The neutron field of a medical LINAC was used to calibrate PADC neutron dosemeters. ► The neutron spectra were derived with a Dy-foil based Bonner Sphere Spectrometer. ► Workplace specific calibration factor were derived for the PADC dosemeters. ► These factors were compared with those obtained in reference neutron fields

  11. Comparison of neutron dose measured by Albedo TLD and etched tracks detector at PNC plutonium fuel facilities

    International Nuclear Information System (INIS)

    Tsujimura, N.; Momose, T.; Shinohara, K.; Ishiguro, H.

    1996-01-01

    Power Reactor and Nuclear Fuel Development Corporation (PNC) has fabricated Plutonium and Uranium Mixed OXide (MOX) fuel for FBR MONJU at Tokai works. In this site, PNC/Panasonic albedo TLDs/1/ are used for personnel neutron monitoring. And a part of workers wore Etched Tracks Detector (ETD) combined with TLD in order to check the accuracy of the neutron dose estimated by albedo TLD. In this paper, the neutron dose measured by TLD and ETD in the routine monitoring is compared at PNC plutonium fuel facilities. (author)

  12. Microcomputer control of automated TLD reader

    International Nuclear Information System (INIS)

    Bjarland, Bert.

    1979-10-01

    The interfacing electronics, the control algorithms and the developed programs of a 6800 microcomputer controlled automated TLD reader are described. The TL reading system is implemented with a photomultiplier tube and a charge-to-pulse converter. The gain of the TL reading system is controlled through the use of a temperature compensated LED reference light source. Automatic compensation of PM tube dark current is optional. The short term stability of TL readings is better than 3 %. (author)

  13. Capacidad administrativa como factor de eficiencia interna y global de las organizaciones

    Directory of Open Access Journals (Sweden)

    Carlos E. Martínez Fajardo

    1997-06-01

    Full Text Available El concepto de eficiencia ha sido precisado y simplificado por los autores de la teoría clásica de la administración en el sentido de maximizar la producción de las organizaciones con los mínimos costos. En el presente artículo se analizará la eficiencia interna y global de las organizaciones de acuerdo con nuevos criterios adicionales que permitan estudiar el problema con un enfoque de mayor complejidad la naturaleza, fines y estructura de las organizaciones, entre ellos la incidencia del factor de este siglo denominado capacidad administrativa.

  14. Conversion factors for the ICRU dose equivalent quantities for calibrating radiation dosemeters

    International Nuclear Information System (INIS)

    Grosswendt, B.; Hohlfeld, K.; Kramer, H.M.; Selbach, H.J.

    1985-02-01

    Report describing the application of conversion factors for monoenergetic photon radiation and for X and gamma reference radiation used for dosemeter calibration with the aid of spherical or rectangular phantoms (environmental and individual monitoring). (DG) [de

  15. Eficiencia de las empresas aseguradoras en Europa

    Directory of Open Access Journals (Sweden)

    Suárez Álvarez, Eva

    2009-01-01

    Full Text Available RESUMEN Los mercados de seguros europeos han evolucionado mucho en los últimos años. Las directrices europeas han fomentado el establecimiento de un mercado de seguros único. Este hecho ha provocado una serie de fusiones y adquisiciones de empresas, así como aumentado la competitividad en los mercados dando lugar a una mayor preocupación por la eficiencia empresarial.Este estudio trata de analizar la eficiencia de cuatro de los principales mercados europeos en el ámbito asegurador, como son Alemania, Francia, Italia y Reino Unido, durante el periodo 2004-2007. Para ello se ha empleado un modelo DEA-CCR input orientado.Los resultados muestran que el mercado italiano es el más eficiente lo cual puede deberse a que está compuesto por un menor número de empresas. Por su parte el mercado británico es el más atomizado, lo que probablemente reduce su ratio de eficiencia a pesar de ser el que mayor número de empresas eficientes posee.ABSTRACT The European Insurance Market has been developed during the last years. With the aim of establishing a Single European Insurance Market, several Directives have been developed. This fact was following by an important process of Mergers and Acquisitions (M&A, and also by an increase in competitive between firms, which were looking for more efficiency.This work analyses efficiency of four of the main European insurance market – Germany, France, Italy and United Kingdom- during the period 2004-2007. For that purpose, we have chosen a DEA-CCR model, input orientation. Results show that Italian market is the most efficient, probably due to being the one with the least number of firms. On the other hand, United Kingdom has a numerous and very heterogeneous market, which maybe reduce it efficiency rate, even when Britain market is that with more efficient firms.

  16. The IAEA/WHO TLD postal dose quality audits for radiotherapy: a perspective of dosimetry practices at hospitals in developing countries

    International Nuclear Information System (INIS)

    Izewska, Joanna; Andreo, Pedro; Vatnitsky, Stanislav; Shortt, Ken R.

    2003-01-01

    Background and purpose: The IAEA/WHO TLD postal programme for external audits of the calibration of high-energy photon beams used in radiotherapy has been in operation since 1969. This work presents a survey of the 1317 TLD audits carried out during 1998-2001. The TLD results are discussed from the perspective of the dosimetry practices in hospitals in developing countries, based on the information provided by the participants in their TLD data sheets. Materials and methods: A detailed analysis of the TLD data sheets is systematically performed at the IAEA. It helps to trace the source of any discrepancy between the TLD measured dose and the user stated dose, and also provides information on equipment, dosimetry procedures and the use of codes of practice in the countries participating in the IAEA/WHO TLD audits. Result: The TLD results are within the 5% acceptance limit for 84% of the participants. The results for accelerator beams are typically better than for Co-60 units. Approximately 75% of participants reported dosimetry data, including details on their procedure for dose determination from ionisation chamber measurements. For the remaining 25% of hospitals, who did not submit these data, the results are poorer than the global TLD results. Most hospitals have Farmer type ionisation chambers calibrated in terms of air kerma by a standards laboratory. Less than 10% of the hospitals use new codes of practice based on standards of absorbed dose to water. Conclusion: Despite the differences in dosimetry equipment, traceability to different standards laboratories and uncertainties arising from the use of various dosimetry codes of practice, the determination of absorbed dose to water for photon beams typically agrees within 2% among hospitals. Correct implementation of any of the dosimetry protocols should ensure that significant errors in dosimetry are avoided

  17. Crecimiento y eficiencia de la industria editorial de Bogotá, Colombia

    Directory of Open Access Journals (Sweden)

    José Luis Rodríguez Pardo

    2012-06-01

    Full Text Available El presente estudio evalúa la eficiencia técnica y el crecimiento en productividad de la industrial editorial en Bogotá durante el período 2000-2007, mediante la aplicación de la técnica de frontera de análisis envolvente de datos determinístico (DEA, siglas en inglés. Para esto, se construye un panel de datos balanceado con base en la información de la Encuesta Anual Manufacturera. Con la descomposición del índice deMalmquist se cuantifica el aporte de la eficiencia técnica y el cambio productivo de la industria para el periodo de estudio de la productividad.

  18. EURADOS intercomparisons in external radiation dosimetry: similarities and differences among exercises for whole-body photon, whole-body neutron, extremity, eye-lens and passive area dosemeters

    International Nuclear Information System (INIS)

    Romero, Ana M.; Grimbergen, Tom; McWhan, Andrew; Stadtmann, Hannes; Fantuzzi, Elena; Clairand, Isabelle; Neumaier, Stefan; Dombrowski, Harald; Figel, Markus

    2016-01-01

    The European Radiation Dosimetry Group (EURADOS) has been organising dosimetry intercomparisons for many years in response to an identified requirement from individual monitoring services (IMS) for independent performance tests for dosimetry systems. The participation in intercomparisons gives IMS the opportunity to show compliance with their own quality management system, compare results with other participants and develop plans for improving their dosimetry systems. In response to growing demand, EURADOS has increased the number of intercomparisons for external radiation dosimetry. Most of these fit into the programme of self-financing intercomparisons for dosemeters routinely used by IMS. This programme is being coordinated by EURADOS working group 2 (WG2). Up to now, this programme has included four intercomparisons for whole-body dosemeters in photon fields, one for extremity dosemeters in photon and beta fields, and one for whole-body dosemeters in neutron fields. Other EURADOS working groups have organised additional intercomparisons including events in 2014 for eye-lens dosemeters and passive area dosemeters for environmental monitoring. In this paper, the organisation and achievements of these intercomparisons are compared in detail focusing on the similarities and differences in their execution. (authors)

  19. Re-assessment of dose from the Vinten extremity dosemeter

    International Nuclear Information System (INIS)

    O'Hagan, J.B.; Pearson, A.J.; Dutt, J.C.

    1989-01-01

    A procedure is described for re-assessing the dose from the Vinten extremity dosemeter using phototransferred thermoluminescence. The technique produces a linear response up to 50 Sv. The re-assessment efficiency is approximately 10% for the first re-assessment and 3-5% for the second re-assessment. The detection threshold values (at the 95% confidence level) are 3 mSv and 9 mSv respectively. (author)

  20. Feasibility of a neutron detector-dosemeter based on single-event upsets in dynamic random-access memories

    International Nuclear Information System (INIS)

    Phillips, G.W.; August, R.A.; Campbell, A.B.; Nelson, M.E.; Guardala, N.A.; Price, J.L.; Moscovitch, M.

    2002-01-01

    The feasibility was investigated of a solid-state neutron detector/dosemeter based on single-event upset (SEU) effects in dynamic random-access memories (DRAMs), commonly used in computer memories. Such a device, which uses a neutron converter material to produce a charged particle capable of causing an upset, would be light-weight, low-power, and could be read simply by polling the memory for bit flips. It would have significant advantages over standard solid-state neutron dosemeters which require off-line processing for track etching and analysis. Previous efforts at developing an SEU neutron detector/dosemeter have suffered from poor response, which can be greatly enhanced by selecting a modern high-density DRAM chip for SEU sensitivity and by using a thin 10 B film as a converter. Past attempts to use 10 B were not successful because the average alpha particle energy was insufficient to penetrate to the sensitive region of the memory. This can be overcome by removing the surface passivation layer before depositing the 10 B film or by implanting 10B directly into the chip. Previous experimental data show a 10 3 increase in neutron sensitivity by chips containing borosilicate glass, which could be used in an SEU detector. The results are presented of simulations showing that the absolute efficiency of an SEU neutron dosemeter can be increased by at least a factor of 1000 over earlier designs. (author)

  1. Results of film dosemeter control irradiations of German dose measurements services, 1969-1974

    International Nuclear Information System (INIS)

    Gummi, V.; Taubert, R.

    1976-01-01

    The dose measurement services of the FRG have been controlling themselves since 1961 by evaluating film dosimeters irradiated in the PTB under standard conditions. This control method is now embodied in a law by the second decree about the standardization of measuring instruments dt. 6th August 1975. During the time 1969-74 the PTB carried out more than 800 annual control irradiations of film dosimeters. In 30% of the cases the evaluation by the measuring services showed an errory higher than +50%/-30%. The dose measuring services partially diverge considerably concerning the distribution of evaluation errors. Particular difficulties seem to exist in the soft x-ray radiation with effective energies less than 30 keV, in the energy range about 100 keV, and in the evaluation of dosemeter irradiated with two different qualities of radiation (double irradiation). (orig.) [de

  2. Optimization of the temperature profiles due to a nitrogen jet impinging on a TLD detector

    International Nuclear Information System (INIS)

    Cohen, I.; Bar-Kohany, T.; German, U.; Ziskind, G.

    2014-01-01

    A study was conducted to simulate the temperature profiles during readout in a typical, commercial thermo-luminescence dosimeter (TLD) chip and to optimize the readout conditions. The study makes use of a previously developed numerical model which calculates the crystal's temperature profile evolution inside a TLD crystal compound. The calculated profiles were implemented in the Randall-Wilkins equation to obtain the estimated glow curve. A number of jet temperature profiles were investigated in order to optimize the readout process. - Highlights: • The temperature profiles in a TLD chip compound were simulated. • Some non-routine heating profiles are proposed. • A better efficiency and shorter time can be obtained with these profiles. • The resulting glow curves were evaluated as well

  3. TLD environmental monitoring at the Institute of Nuclear Engineering in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Taam, I.H. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Caixa Postal 68550, 21945-970 Rio de Janeiro, RJ (Brazil); Rosa, L.A.R. da [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Av. Salvador Allende s/n, Caixa Postal 37760, 22780-160 Rio de Janeiro, RJ (Brazil)], E-mail: lrosa@ird.gov.br; Crispim, V.R. [PEN/COPPE-DNC/POLI/CT/UFRJ, Caixa Postal 68509, 21941-972 Rio de Janeiro, RJ (Brazil)

    2008-09-15

    Since 2003 the Institute of Nuclear Engineering in Rio de Janeiro city, Brazil, operates a new cyclotron, RDS-111, to produce {sup 18}F-Fluorodeoxyglucose to be used in nuclear medicine. Additionally, the IEN radioactive waste repository has been enlarged during the past last years, receiving a considerable amount of radioactive materials. Therefore, it became necessary to evaluate a possible increase of the environmental gamma exposure rates at the institute site due to the operation of the new accelerator and the enlargement of the institute waste repository as well. LiF:Mg,Cu,P, TLD-100H, and TL detectors were employed for environmental kerma rate evaluation and the results were compared with previous results obtained before the RDS-111 operation initialisation and the enlargement of IEN waste repository. No significant contribution for the enhancement of environmental gamma kerma rates was detected.

  4. Eficiencia tecnica y estacionalidad en los procesos de tratamiento de aguas residuales

    Directory of Open Access Journals (Sweden)

    Ramon Sala-Garrido

    2008-01-01

    Full Text Available El análisis de la eficiencia técnica en las plantas de tratamiento de aguas residuales esun fenómeno de creciente actualidad. Son muchas las razones que justifican la necesidad deconocer en detalle las posibles ineficiencias existentes en los procesos de tratamiento. El uso demodelos DEA (Data Envelopment Analysis en este campo ofrece grandes posibilidades conrespecto a la identificación y el conocimiento detallado de los factores que determinan laeficiencia de una planta. La obtención de indicadores de eficiencia asociados a cada uno de losinputs utilizados en el proceso resulta de gran utilidad. Una de las variables que influye en elcomportamiento eficiente de los procesos de tratamiento es la estacionalidad en los flujos.Aunque resulta difícil la cuantificación de esta influencia, en este trabajo se presenta unametodología que permite abordar los efectos de la estacionalidad a través de un análisis detolerancias asociado a los índices de eficiencia técnica. Se lleva a cabo una aplicación empíricapara una muestra de plantas de tratamiento existentes en la Comunidad Valenciana.

  5. Evaluation of two personal dosemeters in polyenergetic mono- and multi-directional neutron fields

    International Nuclear Information System (INIS)

    Nunes, J. C.; Surette, R. A.

    2005-01-01

    The neutron dose-equivalent response of two commercially available electronic personal neutron dosemeters was studied in several laboratory-produced broad-spectrum neutron fields. Fluence-weighted mean energies ranged from 200 keV to 4 MeV; personal dose-equivalent rates ranged from 75 to 10 mSv h -1 ; and angles of incidence were multidirectional, 0 deg., 30 deg. and 60 deg.. Three of these fields have been shown previously to resemble ones found in CANDU (Canadian Deuterium Uranium is a registered trademark of the Atomic Energy of Canada Limited) power plant workplaces. Both dosemeters were found to perform reasonably well across the range of energy spectra and angles of incidence. One type of dosemeter displayed values of the personal dose equivalent that were, at worst, within a factor of ∼2 of the reference values and, at best, within a few per cent of the reference values. The other type displayed values of the personal dose equivalent that were consistently within unity and 20% of the reference values. Although the radiological performance of one was found to be more accurate, this device was also found to be the less rugged of the two. Some of the data acquired in this work were compared with results previously published by others. There was consistency between these sets of data. (authors)

  6. Characteristics and performance of the Sunna high dose dosemeter using green photoluminescence and UV absorption readout methods

    Energy Technology Data Exchange (ETDEWEB)

    Miller, S.D.; Murphy, M.K.; Tinker, M.R.; Kovacs, A.; McLaughlin, W

    2002-07-01

    Growth in the use of ionising radiation for medical sterilisation and the potential for wide-scale international food irradiation have created the need for robust, mass-producible, inexpensive, and highly accurate radiation dosemeters. The Sunna dosemeter, lithium fluoride injection-moulded in a polyethylene matrix, can be read out using either green photoluminescence or ultraviolet (UV) absorption. The Sunna dosemeter can be mass-produced inexpensively with high precision. Both the photoluminescent and the UV absorption reader are simple and inexpensive. Both methods of analysis display negligible humidity effects, minimal dose rate dependence, acceptable post-irradiation effects, and permit measurements with a precision of nearly 1% 1s. The UV method shows negligible irradiation temperature effects from -30 deg. C to +60 deg. C. The photoluminescence method shows negligible irradiation temperature effects above room temperature for sterilisation dose levels and above. The dosimetry characteristics of these two readout methods are presented along with performance data in commercial sterilisation facilities. (author)

  7. Impacto de las inversiones en TI en la eficiencia de los bancos argentinos

    Directory of Open Access Journals (Sweden)

    Ángel Agustín Argañaraz

    2013-03-01

    Full Text Available Las tecnologías de información (TI constituyen en la actualidad una herramienta fundamental para el logro de ventajas competitivas en un contexto sumamente cambiante. Resulta relevante conocer el impacto de su utilización sobre el desempeño de las organizaciones, en particular en sectores como el bancario, que realizan un uso intensivo de información. En el presente trabajo se desarrolla un modelo que posibilita evaluar el impacto de las inversiones en TI sobre la eficiencia de las entidades bancarias. Se utilizó la técnica Data Envelopment Analysis (DEA como herramienta de medición de la eficiencia de acuerdo al modelo elaborado sobre la información obtenida de los estados contables de entidades bancarias de la República Argentina. Los resultados obtenidos demostraron que los bancos alcanzaron un buen nivel de eficiencia global. Se encontró que los más eficientes son las sucursales de entidades financieras del exterior y los bancos locales de capital extranjero.

  8. Development and extension of TLD audit in radiation therapy in the Czech Republic

    International Nuclear Information System (INIS)

    Valenta, J.; Ekendahl, D.

    2005-01-01

    A comprehensive and adequate quality assurance (QA) program is a crucial factor in minimizing gross errors and in reducing uncertainties caused during any of consecutive steps of radiation therapy process. Since 1997, the measuring centre of National Radiation Protection Institute in Prague (NRPI) has been performing TLD audit in external beam radiation therapy via mailed TL dosimeters, as a part of comprehensive QA program. The objective of TLD audit is to check dose delivery accuracy at radiation therapy centers and to inform the State Office for Nuclear Safety (SONS) on the situation. The flexibility of the method enables NRPI to inspect each centre at least once every two years. Compared with the EU average, situation in the Czech Republic seems to be similar. 95 % of measurements show deviation up to 5 % (97 % in the EQUAL network). Nevertheless, the acceptance level is stricter (3 %) in the Czech Republic. This is affordable because o(the small size of the country, and better ability to confirm the results promptly , if tolerance levels are exceeded. Still, 84 % of results meet the criteria of 3 %. Both basic and advanced modes of TLD audit may discover deviations in clinical dosimetry or in treatment planning for reference and non reference .conditions, although they do not provide enough data for proper interpretation of errors. The results show the importance of independent TLD audit as a flexible and operational part of the comprehensive quality assurance program. (authors)

  9. Comparison of the calculated absorbed dose using the Cadplan™ treatment planning software and Tld-100 measurements in an Alderson-Rando phantom for a bronchogenic treatment

    Energy Technology Data Exchange (ETDEWEB)

    Gutiérrez Castillo, J. G., E-mail: jggc59@hotmail.com [Departamento de Física, Hospital de Oncología, IMSS, CMN Siglo XXI, Cuauhtémoc 330 Col. Doctores (Mexico); Álvarez Romero, J. T., E-mail: trinidad.alvarez@inin.gob.mx, E-mail: fisarmandotorres@gmail.com, E-mail: victor.tovar@inin.gob.mx; Calderón, A. Torres, E-mail: trinidad.alvarez@inin.gob.mx, E-mail: fisarmandotorres@gmail.com, E-mail: victor.tovar@inin.gob.mx; M, V. Tovar, E-mail: trinidad.alvarez@inin.gob.mx, E-mail: fisarmandotorres@gmail.com, E-mail: victor.tovar@inin.gob.mx [SSDL, Departamento de Metrología ININ, Salazar, Estado de México 15245 (Mexico)

    2014-11-07

    To verify the accuracy of the absorbed doses D calculated by a TPS Cadplan for a bronchogenic treatment (in an Alderson-Rando phantom) are chosen ten points with the following D's and localizations. Point 1, posterior position on the left edge with 136.4 Gy. Points: 2, 3 and 4 in the left lung with 104.9, 104.3 and 105.8 Gy, respectively; points 5 and 6 at the mediastinum with 192.4 and 173.5 Gy; points 7, 8 and 9 in the right lung with 105.8, 104.2 and 104.7 Gy, and 10 at posterior position on right edge with 143.7 Gy. IAEA type capsules with TLD 100 powder are placed, planned and irradiated. The evaluation of the absorbed dose is carried out a curve of calibration for the LiF response (nC) {sup vs} {sup DW}, to several cavity theories. The traceability for the DW is obtained with a secondary standard calibrated at the NRC (Canada). The dosimetric properties for the materials considered are determined from the Hounsfield numbers reported by the TPS. The stopping power ratios are calculated for nominal spectrum to 6 MV photons. The percent variations among the planned and determined D in all the cases they are < ± 3%.

  10. Determination of the dose rapidity of a 90 Sr beta radiation source using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.; Azorin N, J.; Rivera M, T.

    2000-01-01

    The thermoluminescent dosemeters developed in Mexico, have been used efficiently in environmental and personal dosimetry. When the dose rate of some source is not known can be estimated with the use of thermoluminescent dosemeters taking in account the geometrical array used in the irradiations for reproducibility of the results in posterior irradiations. In this work it was estimated the dose rate of a 90 Sr- 90 Y beta radiation source which is property of the Nuclear Sciences Institute, UNAM, therefore it was l ended to the Metropolitan Autonomous University- Iztapalapa Unit for the characterization of new Tl materials, taking account of the institutional collaboration agreements. (Author)

  11. Characteristics and performances of electronic personal dosemeters

    International Nuclear Information System (INIS)

    Aubert, B.

    2002-01-01

    The regulations have made obligation for 2 years to measure and analyse the amounts of radiations actually received during an operation. The whole of these measurements taken uninterrupted for an immediate reading is indicated like the operational dosimetry, which is carried out with the means of personal electronic dosemeters. This study analyses the legislation relating to this type of dosimetry as well as the requirements in medical environment, and presents an assessment of the characteristics and performances of the devices available on the French market at the beginning of 2002 starting from the information provided by the various manufacturers. (author)

  12. Assessment of eye lens doses in interventional radiology: a simulation in laboratory conditions

    International Nuclear Information System (INIS)

    Cemusova, Z.; Ekendahl, D.; Judas, L.

    2016-01-01

    As workers in interventional radiology belong to one of the most occupationally exposed groups, methods for sufficiently accurate quantification of their external exposure are sought. The objective of the authors' experiment was to investigate the relations between eye lens dose and H p (10), H p (3) or H p (0.07) values measured with a conventional whole-body personal thermoluminescence dosemeter (TLD). Conditions of occupational exposure during common interventional procedures were simulated in laboratory. An anthropomorphic phantom represented a physician. The TLDs were fixed to the phantom in different locations that are common for purposes of personal dosimetry. In order to monitor the dose at the eye lens level during the exposures, a special thermoluminescence eye dosemeter was fixed to the phantom's temple. Correlations between doses measured with the whole-body and the eye dosemeters were found. There are indications that personnel in interventional radiology do not need to be unconditionally equipped with additional eye dosemeters, especially if an appropriate whole-body dosimetry system has been already put into practice. (authors)

  13. Comparative study of thermoluminescent, radiophotoluminescent and photographic dosemeters

    International Nuclear Information System (INIS)

    Deus, S.F.

    1976-01-01

    Comparison was made between the response of three differents dosimetric systems, namely, photographic, thermoluminescent (TL) and radiophotoluminescent (RPL). The comparison was divided in two parts. The first was carried out in known radiation conditions (exposure, normal incidence, energy) and under controlled environment (approximately 27 0 C temperature, approximately 70% relative humidity). Under these conditions, the response as a function of exposure and energy, the relation of the linearity to the energy, the lowest detectable exposure, and the reproducibility, were studied. The response against esposure at 37 KeVef and at 1 MeV was found to be linear in the region of interest to routine personnel dosimetry for all dosimeters except for the filmes. In the second part, the relative response of the dosimeters was verified under the uncontrolled conditions of personnel dosimetry. As the CaSO 4 :Dy is the most sensitive dosimeter, comparison was made using this dosimeter as the standard, in which case one finds that 20 of 29 TLD-100 dosimeters give the same reading within 30%, 13 of 29 RPL dosimeters agree within 30%, and only 3 of 29 films fall within 30% [pt

  14. Measurement of the dose to the family members taking care of thyroid cancer patients undergoing I-131 therapy in nuclear medicine using TLD-100

    International Nuclear Information System (INIS)

    Zehtabian, M.; Dehghan, N.; Danaei Ghazanfarkhani, M.; Haghighatafshar, M.; Sina, S.

    2017-01-01

    The family members or friends of the patients undergoing treatment using radioiodine in nuclear medicine are inevitably exposed to ionization radiation. The purpose of this study is measurement of the dose received by the people taking care of the thyroid cancer patients treated by "1"3"1I. For this purpose, the dose amounts received by 29 people accompanying patients were measured using thermoluminescence dosimeters. A badge containing three TLD-100 chips was given to each caregiver. The people were asked to wear the badges for 24 days, when they are taking care of the patients. Finally the dose to each person was estimated by averaging the readings of the three TLDs. The measured dose amounts to the people were compared with the recommendations of international commissions. According to the results obtained in this study, the amounts of dose received by the caregivers were between 0.03 and 0.38 mSv, with the average of 0.12 mSv. By comparison of the results of this study with the recommendations of International Commission on Radiological Protection (ICRP), it can be observed that the dose to family members of the patients is less than the dose constraints. However, it is recommended that the caregivers be aware of the radiation protection principles in order to reduce their dose. (authors)

  15. Eficiencia de dos pruebas diagnósticas en la determinación de alergia por ácaros en niños

    Directory of Open Access Journals (Sweden)

    Yadira Fuentes

    2008-08-01

    Full Text Available Las enfermedades alérgicas constituyen un problema de salud mundial y los ácaros se encuentran entre sus principales agentes etiológicos. En Cuba se destacan los siguientes: Dermatophagoides pteronyssinus, Dermatophagoides siboney y Blomia tropicalis. Con el objetivo de determinar la eficiencia de la prueba cutánea por punción y la determinación de IgE específica para el diagnóstico de la alergia a estos tres ácaros se desarrolló en el año 2003 un estudio analítico que incluyó 100 niños: 50 no alérgicos y 50 alérgicos que asistieron al Hospital Pediátrico "William Soler" de Ciudad de La Habana. A todos se les realizó la prueba cutánea por punción con tres extractos alergénicos (VALERGEN-DP, VALERGEN-DS y VALERGEN-BT y se les extrajo sangre para la valoración de la IgE ácaro específica; exámenes que mostraron una mayor positividad ante D. pteronyssinus en los niños enfermos. Mientras que en los no alérgicos la prueba cutánea y la IgE para D. pteronyssinus fueron negativas. La prueba cutánea presentó un 100% de especificidad, con una mayor sensibilidad para VALERGEN-DP (88%, extracto con más eficiencia diagnóstica (94%. La IgE expresó los mejores resultados de sensibilidad, especificidad y eficiencia para D. pteronyssinus (78, 100 y 89%, respectivamente. La prueba cutánea por punción fue más eficiente que la determinación de IgE específica para el diagnóstico de las alergias por ácaros. En los enfermos se observó una correlación significativa entre la respuesta cutánea y el nivel de IgE para los ácaros estudiados. Estos datos contribuyeron a mejorar el diagnóstico alergológico y alertan sobre la necesidad de extender el uso de la inmunoterapia específica con vacunas hiposensibilizantes en los niños alérgicos a los ácaros.

  16. Audit on dose delivery by using TLD in Radiotherapy Centers in Malaysia

    International Nuclear Information System (INIS)

    Md Saion Salikin; Taiman Kadni; Husaini Salleh; Asmaliza Hashim; Hasrul Husham Hussain

    2004-01-01

    The External Audit Group (EAQ) is established and supported by IAEA. Its main objective is to audit the accuracy of dose delivery to patients in radiotherapy centres or hospitals in developing countries in IAEA member states. At MINT the operation of EAG is managed by Medical Physics Group and supported by Secondary Standard Dosimetry Laboratory (SSDL), MINT. The selected radiotherapy centers are supplied with TLD powder in capsule form, to be irradiated with the required radiation doses, by their physicists. The irradiated TLD is analysed at SSDL. The result of the audit for a few radiotherapy centres in Malaysia, is presented in brief in this paper. (Author)

  17. A microcontroller based readout unit for a smart personnel monitoring TLD badge

    International Nuclear Information System (INIS)

    Gaonkar, U.P.; Kulkarni, M.S.; Kannan, S.

    1997-01-01

    An automated TLD personnel monitoring system is under development to cope up with the requirements of personnel monitoring of rapidly growing number of radiation workers. The core of the system is a smart TLD badge incorporating a memory device and a microcontroller based readout unit for reading the memory contents of the badge. The memory is used to store personnel data including the accumulated dose data. The reader unit has a serial RS 232C interface for connection to a PC for entering/modifying data in the memory. A password protected software has also been developed in C for entering/modifying the data in the single memory. 3 figs

  18. Methods on TLD management be applicable in nuclear power plantsunder the multi-reactor operational mode

    International Nuclear Information System (INIS)

    Luo Huiyong; Wen Qinghua; Li Ruirong; Yu Enjian

    2006-01-01

    This paper discusses the methods on management of TLD dosimeters adopted in DNMC and other NPPs, analyzes and evaluates their both defects and advantages. Facing the coming of the multi-reactor operational mode applied in NPPs, a new method intelligent management mode is put forward, this optimized method not only assures the accuracy of TLD's measurement but also reduces the cost of production and improves the efficiency of management greatly. (authors)

  19. New KID dosemeter for measurement of cosmic dosimetry

    International Nuclear Information System (INIS)

    Peksova, D.; Kakona, M.; Krist, P.; Kocur, Z.; Larina, K. V.; Ploc, O.

    2018-01-01

    The KID dosemeter is a small semiconductor low-power detector developed for common use. The current design is special designed after measuring cosmic rays on aircraft decks. The design concept is the same world-class devices Internet of Things (IoT). As a detection element detector were tested three variants a) PIN HAMAMATSU S2744-09 photodiode, b) 9 parallel Vishay photodiodes TEMD5080X01, c) 16 Vishay photodiode TEMD5080X01 again in parallel connection. All variants are silicon PIN photodiode. (authors)

  20. Development of a TLD mailed system for remote dosimetry audit for 192Ir HDR and PDR sources

    International Nuclear Information System (INIS)

    Roue, Amelie; Venselaar, Jack L.M.; Ferreira, Ivaldo H.; Bridier, Andre; Dam, Jan van

    2007-01-01

    Background and purpose: In the framework of an ESTRO ESQUIRE project, the BRAPHYQS Physics Network and the EQUAL-ESTRO laboratory have developed a procedure for checking the absorbed dose to water in the vicinity of HDR or PDR sources using a mailed TLD system. The methodology and the materials used in the procedure are based on the existing EQUAL-ESTRO external radiotherapy dose checks. Materials and methods: A phantom for TLD postal dose assurance service, adapted to accept catheters from different HDR afterloaders, has been developed. The phantom consists of three PMMA tubes supporting catheters placed at 120 degrees around a central TLD holder. A study on the use of LiF powder type DTL 937 (Philitech) has been performed in order to establish the TLD calibration in dose-to-water at a given distance from 192 Ir source, as well as to determine all correction factors to convert the TLD reading into absorbed dose to water. The dosimetric audit is based on the comparison between the dose to water measured with the TL dosimeter and the dose calculated by the clinical TPS. Results of the audits are classified in four different levels depending on the ratio of the measured dose to the stated dose. The total uncertainty budget in the measurement of the absorbed dose to water using TLD near an 192 Ir HDR source, including TLD reading, correction factors and TLD calibration coefficient, is determined as 3.27% (1 s). Results: To validate the procedures, the external audit was first tested among the members of the BRAPHYQS Network. Since November 2004, the test has been made available for use by all European brachytherapy centres. To date, 11 centres have participated in the checks and the results obtained are very encouraging. Nevertheless, one error detected has shown the usefulness of this audit. Conclusion: A method of absorbed dose to water determination in the vicinity of an 192 Ir brachytherapy source was developed for the purpose of a mailed TL dosimetry system. The