  1. Surface characterisation and electrochemical behaviour of porous titanium dioxide coated 316L stainless steel for orthopaedic applications

    International Nuclear Information System (INIS)

    Nagarajan, S.; Rajendran, N.

    2009-01-01

    Porous titanium dioxide was coated on surgical grade 316L stainless steel (SS) and its role on the corrosion protection and enhanced biocompatibility of the materials was studied. X-ray diffraction analysis (XRD), atomic force microscopy (AFM), Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDAX) were carried out to characterise the surface morphology and also to understand the structure of the as synthesised coating on the substrates. The corrosion behaviour of titanium dioxide coated samples in simulated body fluid was evaluated using polarisation and impedance spectroscopy studies. The results reveal that the titanium dioxide coated 316L SS exhibit a higher corrosion resistance than the uncoated 316L SS. The titanium dioxide coated surface is porous, uniform and also it acts as a barrier layer to metallic substrate and the porous titanium dioxide coating induces the formation of hydroxyapatite layer on the metal surface.

  2. Investigation of photocatalytic activity of titanium dioxide coating deposited on aluminium alloy substrate by plasma technique

    DEFF Research Database (Denmark)

    Daviðsdóttir, Svava; Soyama, Juliano; Dirscherl, Kai

    2011-01-01

    . Literature consists of large number of publications on titanium dioxide coating for self-cleaning applications, with glass as the main substrate. Only little work is available on TiO2 coating of metallic alloys used for engineering applications. Engineering materials, such as light-weight aluminium and steel...... have wide spread technological applications, where a combination of self-cleaning properties has a huge business potential. The results presented in this paper demonstrate superior photocatalytic properties of TiO2 coated aluminium compared to nano-scale TiO2 coating on glass substrate. The thickness...

  3. The effects of titanium dioxide coatings on light-derived heating and transdermal heat transfer in bovine skin

    NARCIS (Netherlands)

    Bartle, S J; Thomson, D U; Gehring, R; van der Merwe, B. D.

    2017-01-01

    The effects of titanium dioxide coatings of bovine hides on light absorption and transdermal transfer of light-derived heat were investigated. Four hair-on rug hides from Holstein cattle were purchased. Twelve samples about 20 cm on a side were cut from each hide; nine from the black-colored areas,

  4. The effects of titanium dioxide coatings on light-derived heating and transdermal heat transfer in bovine skin

    Science.gov (United States)

    Bartle, S. J.; Thomson, D. U.; Gehring, R.; van der Merwe, D.

    2017-11-01

    The effects of titanium dioxide coatings of bovine hides on light absorption and transdermal transfer of light-derived heat were investigated. Four hair-on rug hides from Holstein cattle were purchased. Twelve samples about 20 cm on a side were cut from each hide; nine from the black-colored areas, and three from the white areas. Samples were randomized and assigned to four coating treatments: (1) white hide with no coating (White), (2) black hide with no coating (Black), (3) black hide with 50% coating (Mid), and (4) black hide with 100% coating (High). Coatings were applied to the black hide samples using a hand sprayer. Lux measurements were taken using a modified lux meter at three light intensities generated with a broad spectrum, cold halogen light source. Reflectance over a wavelength range of 380 to 900 nm was measured using a spectroradiometer. The transdermal transfer of heat derived from absorbed light was measured by applying a broad spectrum, cold halogen light source to the stratum corneum (coated) side of the sample and recording the temperature of the dermis-side using a thermal camera for 10 min at 30-s intervals. At the high light level, the White, Black, Mid, and High coating treatments had different ( P 400 to 750 nm), Black hides reflected 10 to 15% of the light energy, hides with the Mid coating treatment reflected 35 to 40%, and hides with the High coating treatment reflected 70 to 80% of the light energy. The natural White hide samples reflected 60 to 80% of the light energy. The average maximum temperatures at the dermis-side of the hides due to transferred heat were 34.5, 70.1, 55.0, and 31.7, for the White, Black, Mid, and High treatments, respectively. Reflective coatings containing titanium dioxide on cattle hides were effective in reducing light energy absorption and reduced light-derived heat transfer from the skin surface to deeper skin layers.

  5. Improvement of water resistance and dimensional stability of wood through titanium dioxide coating

    Science.gov (United States)

    Qingfeng Sun; Haipeng Yu; Yixing Liu; Jian Li; Yun Lu; John F. Hunt

    2010-01-01

    Moisture absorption and dimensional distortion are the major drawbacks of wood utilization as building material. In this study, poplar wood coated with a thin layer of titanium dioxide (TiO2) was prepared by the cosolvent-controlled hydrothermal method. Subsequently, its moisture absorption and dimensional stability were examined. Scanning...

  6. Titanium dioxide-coated fluorine-doped tin oxide thin films for improving overall photoelectric property

    International Nuclear Information System (INIS)

    Li, Bao-jia; Huang, Li-jing; Ren, Nai-fei; Zhou, Ming

    2014-01-01

    Titanium (Ti) layers were deposited by direct current (DC) magnetron sputtering on commercial fluorine-doped tin oxide (FTO) glasses, followed by simultaneous oxidation and annealing treatment in a tubular furnace to prepare titanium dioxide (TiO 2 )/FTO bilayer films. Large and densely arranged grains were observed on all TiO 2 /FTO bilayer films. The presence of TiO 2 tetragonal rutile phase in the TiO 2 /FTO bilayer films was confirmed by X-ray diffraction (XRD) analysis. The results of parameter optimization indicated that the TiO 2 /FTO bilayer film, which was formed by adopting a temperature of 400 °C and an oxygen flow rate of 15 sccm, had the optimal overall photoelectric property with a figure of merit of 2.30 × 10 −2 Ω −1 , higher than 1.78 × 10 −2 Ω −1 for the FTO single-layer film. After coating a 500 nm-thick AZO layer by DC magnetron sputtering on this TiO 2 /FTO bilayer film, the figure of merit of the trilayer film achieved to a higher figure of merit of 3.12 × 10 −2 Ω −1 , indicating further improvement of the overall photoelectric property. This work may provide a scientific basis and reference for improving overall photoelectric property of transparent conducting oxide (TCO) films.

  7. Titanium dioxide-coated fluorine-doped tin oxide thin films for improving overall photoelectric property

    Energy Technology Data Exchange (ETDEWEB)

    Li, Bao-jia, E-mail: bjia_li@126.com [School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013 (China); Jiangsu Provincial Key Laboratory of Center for Photon Manufacturing Science and Technology, Jiangsu University, Zhenjiang 212013 (China); Huang, Li-jing [School of Materials Science and Engineering, Jiangsu University, Zhenjiang 212013 (China); Jiangsu Provincial Key Laboratory of Center for Photon Manufacturing Science and Technology, Jiangsu University, Zhenjiang 212013 (China); Ren, Nai-fei [Jiangsu Provincial Key Laboratory of Center for Photon Manufacturing Science and Technology, Jiangsu University, Zhenjiang 212013 (China); School of Mechanical Engineering, Jiangsu University, Zhenjiang 212013 (China); Zhou, Ming [The State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China)

    2014-01-30

    Titanium (Ti) layers were deposited by direct current (DC) magnetron sputtering on commercial fluorine-doped tin oxide (FTO) glasses, followed by simultaneous oxidation and annealing treatment in a tubular furnace to prepare titanium dioxide (TiO{sub 2})/FTO bilayer films. Large and densely arranged grains were observed on all TiO{sub 2}/FTO bilayer films. The presence of TiO{sub 2} tetragonal rutile phase in the TiO{sub 2}/FTO bilayer films was confirmed by X-ray diffraction (XRD) analysis. The results of parameter optimization indicated that the TiO{sub 2}/FTO bilayer film, which was formed by adopting a temperature of 400 °C and an oxygen flow rate of 15 sccm, had the optimal overall photoelectric property with a figure of merit of 2.30 × 10{sup −2} Ω{sup −1}, higher than 1.78 × 10{sup −2} Ω{sup −1} for the FTO single-layer film. After coating a 500 nm-thick AZO layer by DC magnetron sputtering on this TiO{sub 2}/FTO bilayer film, the figure of merit of the trilayer film achieved to a higher figure of merit of 3.12 × 10{sup −2} Ω{sup −1}, indicating further improvement of the overall photoelectric property. This work may provide a scientific basis and reference for improving overall photoelectric property of transparent conducting oxide (TCO) films.

  8. Clinical and histomorphometrical study on titanium dioxide-coated external fixation pins

    Directory of Open Access Journals (Sweden)

    Koseki H

    2013-02-01

    Full Text Available Hironobu Koseki,1 Tomohiko Asahara,1 Takayuki Shida,1 Itaru Yoda,1 Hidehiko Horiuchi,1 Koumei Baba,2 Makoto Osaki11Department of Orthopedic Surgery, Graduate School of Medicine, Nagasaki University, 2Industrial Technology Center of Nagasaki, Nagasaki, JapanBackground: Pin site infection is the most common and significant complication of external fixation. In this work, the efficacy of pins coated with titanium dioxide (TiO2 for inhibition of infection was compared with that of stainless steel control pins in an in vivo study.Methods: Pins contaminated with an identifiable Staphylococcus aureus strain were inserted into femoral bone in a rat model and exposed to ultraviolet A light for 30 minutes. On day 14, the animals were sacrificed and the bone and soft tissue around the pin were retrieved. The clinical findings and histological findings were evaluated in 60 samples.Results: Clinical signs of infection were present in 76.7% of untreated pins, but in only 36.7% of TiO2-coated pins. The histological bone infection score and planimetric rate of occupation for bacterial colonies and neutrophils in the TiO2-coated pin group were lower than those in the control group. The bone-implant contact ratio of the TiO2-coated pin group was significantly higher (71.4% than in the control pin group (58.2%. The TiO2 was successful in decreasing infection both clinically and histomorphometrically.Conclusion: The photocatalytic bactericidal effect of TiO2 is thought to be useful for inhibiting pin site infection after external fixation.Keywords: titanium dioxide, external fixation, bactericidal activity, Staphylococcus aureus

  9. Clinical and histomorphometrical study on titanium dioxide-coated external fixation pins.

    Science.gov (United States)

    Koseki, Hironobu; Asahara, Tomohiko; Shida, Takayuki; Yoda, Itaru; Horiuchi, Hidehiko; Baba, Koumei; Osaki, Makoto

    2013-01-01

    Pin site infection is the most common and significant complication of external fixation. In this work, the efficacy of pins coated with titanium dioxide (TiO(2)) for inhibition of infection was compared with that of stainless steel control pins in an in vivo study. Pins contaminated with an identifiable Staphylococcus aureus strain were inserted into femoral bone in a rat model and exposed to ultraviolet A light for 30 minutes. On day 14, the animals were sacrificed and the bone and soft tissue around the pin were retrieved. The clinical findings and histological findings were evaluated in 60 samples. Clinical signs of infection were present in 76.7% of untreated pins, but in only 36.7% of TiO(2)-coated pins. The histological bone infection score and planimetric rate of occupation for bacterial colonies and neutrophils in the TiO(2)-coated pin group were lower than those in the control group. The bone-implant contact ratio of the TiO(2)-coated pin group was significantly higher (71.4%) than in the control pin group (58.2%). The TiO(2) was successful in decreasing infection both clinically and histomorphometrically. The photocatalytic bactericidal effect of TiO(2) is thought to be useful for inhibiting pin site infection after external fixation.

  10. Pre-post evaluation of effects of a titanium dioxide coating on environmental contamination of an intensive care unit: the TITANIC study.

    Science.gov (United States)

    de Jong, B; Meeder, A M; Koekkoek, K W A C; Schouten, M A; Westers, P; van Zanten, A R H

    2018-07-01

    Among patients admitted to European hospitals or intensive care units (ICUs), 5.7% and 19.5% will encounter healthcare-associated infections (HAIs), respectively, and antimicrobial resistance is emerging. As hospital surfaces are contaminated with potentially pathogenic bacteria, environmental cleanliness is an essential aspect to reduce HAIs. To address the efficacy of a titanium dioxide coating in reducing the microbial colonization of environmental surfaces in an ICU. A prospective, controlled, single-centre pilot study was conducted to examine the effect of a titanium dioxide coating on the microbial colonization of surfaces in an ICU. During the pre- and post-intervention periods, surfaces were cultured with agar contact plates (BBL RODAC plates). Factors that were potentially influencing the bacterial colonization of surfaces were recorded. A repeated measurements analysis within a hierarchic multi-level framework was used to analyse the effect of the intervention, controlling for the explanatory variables. The mean ratio for the total number of colony-forming units (cfus) in a room between the pre- and post-intervention periods was 0.86 (standard deviation 0.57). The optimal model included the following explanatory variables: intervention (P=0.065), week (P=0.002), culture surfaces (P<0.001), ICU room (P=0.039), and interaction between intervention and week (P=0.002) and between week and culture surfaces (P=0.031). The effect of the intervention on the number of cfus from all culture plates in Week 4 between the pre- and post-intervention periods was -0.47 (95% confidence interval -0.24 to - 0.70). This study found that a titanium dioxide coating had no effect on the microbial colonization of surfaces in an ICU. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  11. Outstanding field emission properties of wet-processed titanium dioxide coated carbon nanotube based field emission devices

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Jinzhuo; Ou-Yang, Wei, E-mail: ouyangwei@phy.ecnu.edu.cn; Chen, Xiaohong; Guo, Pingsheng; Piao, Xianqing; Sun, Zhuo [Engineering Research Center for Nanophotonics and Advanced Instrument, Ministry of Education, Department of Physics, East China Normal University, 3663 North Zhongshan Road, Shanghai 200062 (China); Xu, Peng; Wang, Miao [Department of Physics, Zhejiang University, 38 ZheDa Road, Hangzhou 310027 (China); Li, Jun [Department of Electronic Science and Technology, Tongji University, 4800 Caoan Road, Shanghai 201804 (China)

    2015-02-16

    Field emission devices using a wet-processed composite cathode of carbon nanotube films coated with titanium dioxide exhibit outstanding field emission characteristics, including ultralow turn on field of 0.383 V μm{sup −1} and threshold field of 0.657 V μm{sup −1} corresponding with a very high field enhancement factor of 20 000, exceptional current stability, and excellent emission uniformity. The improved field emission properties are attributed to the enhanced edge effect simultaneously with the reduced screening effect, and the lowered work function of the composite cathode. In addition, the highly stable electron emission is found due to the presence of titanium dioxide nanoparticles on the carbon nanotubes, which prohibits the cathode from the influence of ions and free radical created in the emission process as well as residual oxygen gas in the device. The high-performance solution-processed composite cathode demonstrates great potential application in vacuum electronic devices.

  12. Pediatric cuffed endotracheal tubes

    Directory of Open Access Journals (Sweden)

    Neerja Bhardwaj

    2013-01-01

    Full Text Available Endotracheal intubation in children is usually performed utilizing uncuffed endotracheal tubes for conduct of anesthesia as well as for prolonged ventilation in critical care units. However, uncuffed tubes may require multiple changes to avoid excessive air leak, with subsequent environmental pollution making the technique uneconomical. In addition, monitoring of ventilatory parameters, exhaled volumes, and end-expiratory gases may be unreliable. All these problems can be avoided by use of cuffed endotracheal tubes. Besides, cuffed endotracheal tubes may be of advantage in special situations like laparoscopic surgery and in surgical conditions at risk of aspiration. Magnetic resonance imaging (MRI scans in children have found the narrowest portion of larynx at rima glottides. Cuffed endotracheal tubes, therefore, will form a complete seal with low cuff pressure of <15 cm H 2 O without any increase in airway complications. Till recently, the use of cuffed endotracheal tubes was limited by variations in the tube design marketed by different manufacturers. The introduction of a new cuffed endotracheal tube in the market with improved tracheal sealing characteristics may encourage increased safe use of these tubes in clinical practice. A literature search using search words "cuffed endotracheal tube" and "children" from 1980 to January 2012 in PUBMED was conducted. Based on the search, the advantages and potential benefits of cuffed ETT are reviewed in this article.

  13. Titanium

    Science.gov (United States)

    Woodruff, Laurel G.; Bedinger, George M.; Piatak, Nadine M.; Schulz, Klaus J.; DeYoung,, John H.; Seal, Robert R.; Bradley, Dwight C.

    2017-12-19

    Titanium is a mineral commodity that is essential to the smooth functioning of modern industrial economies. Most of the titanium produced is refined into titanium dioxide, which has a high refractive index and is thus able to impart a durable white color to paint, paper, plastic, rubber, and wallboard. Because of their high strength-to-weight ratio and corrosion resistance, titanium metal and titanium metal alloys are used in the aerospace industry as well as for welding rod coatings, biological implants, and consumer goods.Ilmenite and rutile are currently the principal titanium-bearing ore minerals, although other minerals, including anatase, perovskite, and titanomagnetite, could have economic importance in the future. Ilmenite is currently being mined from two large magmatic deposits hosted in rocks of Proterozoic-age anorthosite plutonic suites. Most rutile and nearly one-half of the ilmenite produced are from heavy-mineral alluvial, fluvial, and eolian deposits. Titanium-bearing minerals occur in diverse geologic settings, but many of the known deposits are currently subeconomic for titanium because of complications related to the mineralogy or because of the presence of trace contaminants that can compromise the pigment production process.Global production of titanium minerals is currently dominated by Australia, Canada, Norway, and South Africa; additional amounts are produced in Brazil, India, Madagascar, Mozambique, Sierra Leone, and Sri Lanka. The United States accounts for about 4 percent of the total world production of titanium minerals and is heavily dependent on imports of titanium mineral concentrates to meet its domestic needs.Titanium occurs only in silicate or oxide minerals and never in sulfide minerals. Environmental considerations for titanium mining are related to waste rock disposal and the impact of trace constituents on water quality. Because titanium is generally inert in the environment, human health risks from titanium and titanium

  14. Enhanced photocatalytic activity of nano titanium dioxide coated on ethanol-soluble carbon nanotubes

    International Nuclear Information System (INIS)

    Fu, Xiaofei; Yang, Hanpei; He, Kuanyan; Zhang, Yingchao; Wu, Junming

    2013-01-01

    Graphical abstract: Homogenous and dense spreading of TiO 2 on surface modified CNTs and improved photocatalytic performance of TiO 2 was achieved by coupling TiO 2 with ethanol-soluble CNTs. Display Omitted Highlights: ► Ethanol-soluble CNTs were acquired by surface modification. ► Enhanced photoactivity of TiO 2 coated on modified CNTs was obtained. ► Improved activity of TiO 2 is attributed to the intimate contact between TiO 2 and CNTs. ► Dense heterojunctions through Ti–O–CNTs at the interface is proposed. -- Abstract: Surface functionalized carbon nanotubes (CNTs) with ethanol solubility were synthesized and the CNTs–TiO 2 nanocomposites were prepared by coupling of TiO 2 with modified CNTs through a sol–gel method. The as-prepared CNTs and composites were characterized and the composite samples were evaluated for their photocatalytic activity toward the degradation of aqueous methyl orange. It is showed that the acid oxidation of CNTs leads to the embedding of oxygenated functional groups, and as a result, the acid-treated CNTs in turn may serve as chemical reactors for subsequent covalent grafting of octadecylamine. Improved photocatalytic performance of CNTs–TiO 2 composites was obtained, which is mainly attributed to the high dispersion of TiO 2 on ethanol-soluble CNTs and the intimate contact between TiO 2 and CNTs resulted from the dense heterojunctions through the Ti-O-C structure at the interface between TiO 2 and CNTs.

  15. Cuffed endotracheal tubes in paediatrics

    African Journals Online (AJOL)

    cuffed endotracheal tubes (CETTs) in children who are younger than eight years old. Most paediatric ... the smallest functional part of the infant airway, because the ... During the 2003 severe acute respiratory syndrome (SARS) outbreak in ...

  16. Titanium

    DEFF Research Database (Denmark)

    Fage, Simon W; Muris, Joris; Jakobsen, Stig S

    2016-01-01

    Exposure to titanium (Ti) from implants and from personal care products as nanoparticles (NPs) is common. This article reviews exposure sources, ion release, skin penetration, allergenic effects, and diagnostic possibilities. We conclude that human exposure to Ti mainly derives from dental...... and medical implants, personal care products, and foods. Despite being considered to be highly biocompatible relative to other metals, Ti is released in the presence of biological fluids and tissue, especially under certain circumstances, which seem to be more likely with regard to dental implants. Although...... most of the studies reviewed have important limitations, Ti seems not to penetrate a competent skin barrier, either as pure Ti, alloy, or as Ti oxide NPs. However, there are some indications of Ti penetration through the oral mucosa. We conclude that patch testing with the available Ti preparations...

  17. Blind Naso-Endotracheal Intubation

    African Journals Online (AJOL)

    Difficult endotracheal intubation techniques include, use of fiberoptic bronchoscope, intubating laryngeal mask airway, tracheostomy, blind nasotracheal and retrograde intubation. According to the Difficult Airway Society guidelines, intubating with the aid of a fiberoptic scope has taken its place as the standard adjuvant for.

  18. Comparing Titanium Release from Ceramic Tiles using a waste material characterization test - Influence of Calcium and Organic Matter concentrations

    DEFF Research Database (Denmark)

    Heggelund, Laura Roverskov; Hansen, Steffen Foss; Astrup, Thomas Fruergaard

    2015-01-01

    Nanomaterials are beneficial in the building industry to enhance or add certain features to commonly used materials. One example is the use of nano-titanium dioxide in the surface coating of ceramic tiles, to make the tiles surface self-cleaning. At the end of life stage, ceramic tiles might...... to assess if nano-titanium dioxide coated ceramic tiles are suitable for depositing in a landfill or not. Specifically, we used compliance batch test method, which is a simple test evaluating the release from a solid material to an aqueous media during 24 hrs. If nano-Ti particles are released from solid...... immediately after the 24 hrs. test using single particle ICPMS and Transmission Electron Microscopy imaging. The preliminary results suggest that nanoparticulate titanium is released from both tiles – with and without nano-titanium dioxide coating. The size distributions of the released particles are similar...

  19. Treatment of hypertension following endotracheal intubation

    African Journals Online (AJOL)

    Treatment of hypertension following endotracheal intubation. A study comparing the efficacy of labetalol, practolol and placebo. R. J. MAHARAJ, M. THOMPSON, J. G. BROCK-UTNE,. J. W. DOWNING. R. WI LLlAMSON,. Summary. Labetalol, a new adrenergic receptor antagonist, has both a- and B-blocking properties.

  20. A change in humidification system can eliminate endotracheal tube occlusion.

    Science.gov (United States)

    Doyle, Alex; Joshi, Manasi; Frank, Peter; Craven, Thomas; Moondi, Parvez; Young, Peter

    2011-12-01

    Inadequate airway humidification can result in endotracheal tube occlusion. There is evidence that heat and moisture exchangers (HMEs) are more prone to endotracheal tube occlusion than heated humidifiers (HHs) that contain a heated wire circuit. We aimed to compare the incidence of endotracheal tube occlusion while introducing a new dual-heated wire circuit HH in place of an established hydrophobic HME. This was a prospective observational study. All patients who required intubation were included in our analysis. Univariate statistical analysis was performed using a Fisher exact test. P humidification exclusively by HH. In the subsequent 18-month period, there were no further episodes of endotracheal tube occlusion. Our study demonstrates that there is a significant increase in the incidence of endotracheal tube occlusion when using a hydrophobic HME compared with an HH and that using a dual-heated wire circuit HH can eliminate endotracheal tube occlusion. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Laryngotracheal Injury following Prolonged Endotracheal Intubation

    Directory of Open Access Journals (Sweden)

    J. Mehdizadeh

    2006-07-01

    Full Text Available Background: Prolonged endotracheal intubation is a growing method for supporting ventilation in patients who require intensive care. Despite considerable advancement in endotracheal intubation, this method still has some complications; the most important is laryngo-tracheal injuries. Methods: Over a 2-year period, this retrospective study was conducted on 57 patients with history of prolonged intubation who were referred to the ENT Department of Amir Alam Hospital. For each patient, a complete evaluation including history, physical examination, and direct laryngoscopy and bronchoscopy was done under general anesthesia. Results: Fifty-seven patients (44 male; mean age, 23.014.7 years were studied. Mean intubation period was 15.88 days. The most common presenting symptom was dyspnea (62%. Head trauma was responsible for most cases of intubation (72.4%. The most common types of tracheal and laryngeal lesions were tracheal (56.9% and subglottic (55.2% stenosis, respectively. Mean length of tracheal stenosis was 0.810.83 cm. There was a statistically significant relationship between length of tracheal stenosis and intubation period (P=0.0001 but no relation was observed between tracheal stenosis and age, sex, and etiology of intubation (All P=NS. Among the glottic lesions, inter- arytenoids adhesion was the most common lesion (25.9%. No statistically significant relation was found between glottic and subglottic lesions and age, sex and intubation period (all P=NS. Length of stenosis and intubation period was significantly greater in tracheal/ subglottic lesions than those in glottic/ supraglottic lesions (all P=NS. Conclusion: After prolonged endotracheal intubation, laryngo-tracheal lesions had no relation with patient’s age, sex, and cause of intubation.There was direct relation between length of tracheal stenosis and intubation period. Glottic lesions were more commonly observed in head trauma patients. Lesion length and intubation

  2. Endotracheal ectopic parathyroid adenoma mimicking asthma

    Directory of Open Access Journals (Sweden)

    M. Akif Özgül

    2014-01-01

    Full Text Available Primary benign tumors of the trachea are uncommon. These tumors may cause tracheal occlusion and lead to a misdiagnosis of asthma. Ectopic parathyroid adenoma (EPA can be seen anywhere between the mandibular angle and the mediastinum. The distal part of the trachea is a rare location for EPA, and EPA obstructing the endotracheal lumen has not been reported in the literature. We herein describe a 52-year-old female with a several-year history of asthma treatment who presented with progressive dyspnea. Computed tomography revealed a mass that was obstructing the tracheal lumen. Total mass excision was performed via endobronchial treatment, and pathologic examination revealed EPA.

  3. Laryngeal Chondroma: An Unusual Complication Endotracheal Entubation.

    Science.gov (United States)

    Gökdoğan, Ozan; Koybasioglu, Ahmet; Ileri, Fikret

    2016-06-01

    Laryngeal cartilaginous framework tumors are very rare. Chondroma and chondrosarcoma are the most common types of these tumors. A 27-year-old man with a history of intubation presented with exercise-induced dyspnea. A computed tomography scan of larynx showed a rounded and circumscribed mass without infiltration of the adjacent structures which obstructs 75% of airway. Histopathological investigation of the mass revealed the chondroma of the larynx. The patients' history of intubation trauma with the subsequent progressive onset of clinical symptoms demonstrates the relationship between these 2 entities. Clinicians should consider laryngeal chondroma in the differential diagnosis of dyspnea after endotracheal intubation.

  4. Endotracheal expandable metallic stent placement in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, S; Tanabe, Y; Fujiwara, Y; Koyama, T; Tanigawa, N; Kobayashi, M; Katsube, Y; Nakamura, H [Tottori Univ. School of Medicine, Yonago (Japan). Dept. of Radiology Research Inst. for Microbial Diseases, Osaka (Japan). Dept. of Radiology

    1991-01-01

    Various types of Gianturco zig-zag wire stent were implanted into the tracheas of 4 dogs to define the suitable characteristics of the endotracheal wire stent in these animals. These stents were constructed of 0.45, and 0.33 mm stainless steel wire. The diameter of the fully expanded stents was 3 cm and their lengths were 2, 3, and 4 cm. The 2 cm stent constructed of 0.33 mm wire showed minimum pathologic changes of the trachea of the dog compared to the other stents, and at the same time had a complete covering of ciliated columnar epithelium over the stent surface. (orig.).

  5. Accidental transection of flexometallic endotracheal tube during partial maxillectomy

    Directory of Open Access Journals (Sweden)

    Sushma D Ladi

    2011-01-01

    Full Text Available We report a rare case of an 18-year-old female patient in whom accidental sectioning of flexometallic endotracheal tube occurred during partial maxillectomy for mass lesion under general anaesthesia. She was managed successfully by tracheostomy.

  6. Warming Endotracheal Tube in Blind Nasotracheal Intubation throughout Maxillofacial Surgeries

    Directory of Open Access Journals (Sweden)

    Hamzeh Hosseinzadeh

    2013-12-01

    Conclusion: In conclusion, our study showed that using an endotracheal tube softened by warm water could reduce the incidence and severity of epistaxis during blind nasotracheal intubation; however it could not facilitate blind nasotracheal intubation.

  7. Sudden endotracheal tube block in a patient of Achalasia Cardia

    Directory of Open Access Journals (Sweden)

    Ajit Gupta

    2012-01-01

    Full Text Available Endotracheal tube block due to various mechanical causes such as mucous, blood clot, denture, and ampoules have been reported. A patient of achalasia cardia with chronic passive aspiration pneumonitis developed mucoid mass in the respiratory passage which dislodged during the surgical procedure. The episode occurred almost an hour after induction of anesthesia and the dislodged mucoid mass blocked the lumen of endotracheal tube, leading to hypoxia and impending cardiac arrest. However, the patient was salvaged by replacing the tube.

  8. Titanium Dioxide Coatings Sprayed by a Water-Stabilized Plasma Gun (WSP) with Argon and Nitrogen as the Powder Feeding Gas: Differences in Structural, Mechanical and Photocatalytic Behavior

    Czech Academy of Sciences Publication Activity Database

    Ctibor, Pavel; Pala, Zdeněk; Sedláček, J.; Štengl, Václav; Píš, I.; Zahoranová, T.; Nehasil, V.

    2012-01-01

    Roč. 21, 3-4 (2012), s. 425-434 ISSN 1059-9630 Institutional research plan: CEZ:AV0Z20430508; CEZ:AV0Z40320502 Keywords : bandgap * photocatalysis * resistivity * spectroscopy * TiO2 Subject RIV: JK - Corrosion ; Surface Treatment of Materials; CA - Inorganic Chemistry (UACH-T) Impact factor: 1.481, year: 2012 http://www.springerlink.com/content/1873259j2474168w/fulltext.pdf

  9. Titanium ; dream new material

    International Nuclear Information System (INIS)

    Lee, Yong Tae; Kim Seung Eon; Heoon, Yong Taek; Jung, Hui Won

    2001-11-01

    The contents of this book are history of Titanium, present situation of Titanium industry, property of Titanium alloy, types of it, development of new alloy of Titanium smelting of Titanium, cast of Titanium and heat treatment of Titanium, Titanium alloy for plane, car parts, biological health care, and sport leisure and daily life, prospect, and Titanium industrial development of Titanium in China.

  10. Endotracheal intubation skill acquisition by medical students

    Directory of Open Access Journals (Sweden)

    Henry E. Wang MD MS

    2011-08-01

    Full Text Available During the course of their training, medical students may receive introductory experience with advanced resuscitation skills. Endotracheal intubation (ETI – the insertion of a breathing tube into the trachea is an example of an important advanced resuscitation intervention. Only limited data characterize clinical ETI skill acquisition by medical students. We sought to characterize medical student acquisition of ETI procedural skill.11Presented as a poster discussion on 17 October 2007 at the annual meeting of the American Society of Anesthesiologists in San Francisco, CA.The study included third-year medical students participating in a required anesthesiology clerkship. Students performed ETI on operating room patients under the supervision of attending anesthesiologists. Students reported clinical details of each ETI effort, including patient age, sex, Mallampati score, number of direct laryngoscopies and ETI success. Using mixed-effects regression, we characterized the adjusted association between ETI success and cumulative ETI experience.ETI was attempted by 178 students on 1,646 patients (range 1–23 patients per student; median 9 patients per student, IQR 6–12. Overall ETI success was 75.0% (95% CI 72.9–77.1%. Adjusted for patient age, sex, Mallampati score and number of laryngoscopies, the odds of ETI success improved with cumulative ETI encounters (odds ratio 1.09 per additional ETI encounter; 95% CI 1.04–1.14. Students required at least 17 ETI encounters to achieve 90% predicted ETI success.In this series medical student ETI proficiency was associated with cumulative clinical procedural experience. Clinical experience may provide a viable strategy for fostering medical student procedural skills.

  11. Temporal comparison of ultrasound vs. auscultation and capnography in verification of endotracheal tube placement

    DEFF Research Database (Denmark)

    Pfeiffer, P; Rudolph, S S; Neimann, Jens Dupont Børglum

    2011-01-01

    This study compared the time consumption of bilateral lung ultrasound with auscultation and capnography for verifying endotracheal intubation.......This study compared the time consumption of bilateral lung ultrasound with auscultation and capnography for verifying endotracheal intubation....

  12. Immobilization of nanoparticle titanium dioxide membrane on polyamide fabric by low temperature hydrothermal method

    International Nuclear Information System (INIS)

    Zhang Hui; Yang Lu

    2012-01-01

    A thin layer of nanoparticle titanium dioxide was immobilized on polyamide 6 (PA6) fiber using titanium sulfate and urea at low temperature hydrothermal condition. The titanium dioxide loaded fabric was characterized by scanning electron microscopy, transmission electron microscopy, X-ray diffraction, Fourier transform infrared spectroscopy, differential scanning calorimetry and thermal gravimetry techniques. The optical and mechanical properties, water absorption and degradation of methylene blue dye under ultraviolet (UV) irradiation of the PA6 fabric before and after treatments were also examined. It was found that when PA6 fabric was treated in titanium sulfate and urea aqueous solution, anatase nanocrystalline titanium dioxide was synthesized and simultaneously adhered onto the fiber surface. The average crystal size of titanium dioxide nanoparticles was about 13.2 nm. The thermal behavior of PA6 fiber distinctly changed and the onset decomposition temperature decreased. As compared with the untreated fabric, the protection against UV radiation was improved. The water absorbency increased slightly. As the fabric dimensions were reduced in warp and weft directions, the breaking load and tensile strain increased to some extent. The titanium dioxide coated fabric could degradate methylene blue dye under UV irradiation. - Highlights: ► We employed a method to immobilize TiO 2 nanoparticle on polyamide fiber. ► We fabricated the TiO 2 -coated polyamide fabric with the photocatalytic activity. ► The modification method may be suitable for the potential applications.

  13. influence of head flexion after endotracheal intuba- tion on ...

    African Journals Online (AJOL)

    David Ofori-Adjei

    2008-09-01

    Sep 1, 2008 ... Cataract is a common cause of visual impairment in older individuals. ... After induction of general anesthesia and endotracheal intubation, the ..... Stress re- sponse to tracheal intubation in patients undergoing coronary artery surgery: direct laryngoscopy versus an intubating laryngeal mask airway.

  14. The effectiveness of an endotracheal tube holder

    Directory of Open Access Journals (Sweden)

    Byung Gun Lim

    2016-01-01

    Full Text Available The security of the endotracheal tube (ETT is important in the anesthesia and intensive care settings. Recently, an ETT holder instead of an adhesive tape is frequently used to provide the fixation of the ETT. There are some studies that focused on the effectiveness of the ETT holder in preventing displacement of ETT compared to an adhesive tape (1, 2. I have experienced the use of an ETT holder (E-holder, KS medical, Bucheon, Korea in many different anesthesia settings and recognized its usefulness and convenience other than ETT security in the following specific settings.  Firstly, the ETT holder is definitely effective for patients undergoing procedures that frequently require the adjustment of ETT (or double lumen tube location including thoracic surgery. The location of double lumen tube needed for lung separation can be modified for effective ventilation during anesthetic induction or surgery, and after position changes. The tube can be easily relocated to the proper place for lung separation and effective ventilation by unlocking/relocking the button of the ETT holder under flexible bronchoscopic guidance (Fig. 1A, which can facilitate the operative procedure to be performed easily and quickly. Secondly, the ETT holder can be useful in procedures requiring the prone position (3. Especially, it is useful in all circumstances requiring the adjustment of ETT in the prone position. For instance, it is definitely useful for patients with Duchene muscular dystrophy undergoing scoliosis surgery under prone position. Adolescent patients with Duchene muscular dystrophy frequently have tracheobronchial malacia. If so, the airway pressure can be elevated due to the narrowing of the lesion of malacia when changed to the prone position (4. To overcome this problem, a reinforced ETT should be relocated so that it passes the narrowed tracheal lesion under flexible bronchoscopic guidance (Fig. 1B. However, the approach for this management is somewhat

  15. Laryngeal granuloma: a complication of prolonged endotracheal intubation.

    OpenAIRE

    Keiser, G. J.; Bozentka, N. E.; Gold, B. D.

    1991-01-01

    Laryngeal granuloma is an uncommon complication arising from irritation of the laryngeal structures. We present a case where bilateral laryngeal granulomas became clinically evident 3 mo after orthognathic surgery. The patient, a 19-yr-old female, developed acute dyspnea after experiencing gradual voice loss. Excision of the lesions under endotracheal general anesthesia led to an uneventful outcome. The causes, predisposing factors, diagnostic features, and treatment of laryngeal granuloma ar...

  16. Endotracheal tube cuff pressure monitoring during neurosurgery - Manual vs. automatic method

    Directory of Open Access Journals (Sweden)

    Mukul Kumar Jain

    2011-01-01

    Full Text Available Background: Inflation and assessment of the endotracheal tube cuff pressure is often not appreciated as a critical aspect of endotracheal intubation. Appropriate endotracheal tube cuff pressure, endotracheal intubation seals the airway to prevent aspiration and provides for positive-pressure ventilation without air leak. Materials and Methods: Correlations between manual methods of assessing the pressure by an experienced anesthesiologists and assessment with maintenance of the pressure within the normal range by the automated pressure controller device were studied in 100 patients divided into two groups. In Group M, endotracheal tube cuff was inflated manually by a trained anesthesiologist and checked for its pressure hourly by cuff pressure monitor till the end of surgery. In Group C, endotracheal tube cuff was inflated by automated cuff pressure controller and pressure was maintained at 25-cm H 2 O throughout the surgeries. Repeated measure ANOVA was applied. Results: Repeated measure ANOVA results showed that average of endotracheal tube cuff pressure of 50 patients taken at seven different points is significantly different (F-value: 171.102, P-value: 0.000. Bonferroni correction test shows that average of endotracheal tube cuff pressure in all six groups are significantly different from constant group (P = 0.000. No case of laryngomalacia, tracheomalacia, tracheal stenosis, tracheoesophageal fistula or aspiration pneumonitis was observed. Conclusions: Endotracheal tube cuff pressure was significantly high when endotracheal tube cuff was inflated manually. The known complications of high endotracheal tube cuff pressure can be avoided if the cuff pressure controller device is used and manual methods cannot be relied upon for keeping the pressure within the recommended levels.

  17. Use of Microcuff ® endotracheal tubes in paediatric laparoscopic surgeries

    Directory of Open Access Journals (Sweden)

    Rameshwar Mhamane

    2015-01-01

    Full Text Available Background and Aims: Traditionally, uncuffed endotracheal tubes have been used in children. Cuffed tubes may be useful in special situations like laparoscopy. Microcuff ® endotracheal tube is a specifically designed cuffed endotracheal tube for the paediatric airway. We studied the appropriateness of Microcuff ® tube size selection, efficacy of ventilation, and complications, in children undergoing laparoscopy. Methods: In a prospective, observational study, 100 children undergoing elective laparoscopy were intubated with Microcuff ® tube as per recommended size. We studied appropriateness of size selection, sealing pressure, ability to ventilate with low flow, quality of capnography and post-extubation laryngospasm or stridor. Results: Mean age of the patients was 5.44 years (range 8 months 5 days-9 years 11 months. There was no resistance for tube passage during intubation in any patient. Leak on intermittent positive pressure ventilation at airway pressure ≤20 cm H 2 O was present in all patients. Mean sealing pressure was 11.72 (1.9 standard deviation [SD] cm H 2 O. With the creation of pnemoperitoneum, mean intracuff pressure increased to 12.48 (3.12 SD cm H 2 O. With head low positioning, mean cuff pressure recorded was 13.32 (2.92 SD. Ventilation at low flow (mean flow 1 L/min, plateau-type capnography was noted in all patients. Mean duration of intubation was 83.50 min. Coughing at extubation occurred in 6 patients. Partial laryngospasm occurred in 4 patients, which responded to continuous positive airway pressure via face mask. Severe laryngospasm or stridor was not seen in any patient. Conclusion: Microcuff ® tubes can be safely used in children if size selection recommendations are followed and cuff pressure is strictly monitored. Advantages are better airway seal and effective ventilation, permitting use of low flows.

  18. A new heat and moisture exchanger for laryngectomized patients: endotracheal temperature and humidity

    NARCIS (Netherlands)

    Scheenstra, R.J.; Muller, S.H.; Vincent, A.; Ackerstaff, A.H.; Jacobi, I.; Hilgers, F.J.M.

    2011-01-01

    Objective: To assess the endotracheal temperature and humidity and clinical effects of 2 models of a new heat and moisture exchanger (HME): Rplus, which has regular breathing resistance, and Lplus, which has lower breathing resistance. Methods: We measured endotracheal temperature and humidity in 10

  19. A new heat and moisture exchanger for laryngectomized patients: endotracheal temperature and humidity

    NARCIS (Netherlands)

    Scheenstra, Renske J.; Muller, Saar H.; Vincent, Andrew; Ackerstaff, Annemieke H.; Jacobi, Irene; Hilgers, Frans J. M.

    2011-01-01

    To assess the endotracheal temperature and humidity and clinical effects of 2 models of a new heat and moisture exchanger (HME): Rplus, which has regular breathing resistance, and Lplus, which has lower breathing resistance. We measured endotracheal temperature and humidity in 10 laryngectomized

  20. Evaluation of a new laser-resistant fabric and copper foil-wrapped endotracheal tube.

    Science.gov (United States)

    Sosis, M B; Braverman, B; Caldarelli, D D

    1996-07-01

    The risk of an endotracheal tube's combustion during laser airway surgery necessitates the use of special anesthetic techniques and equipment to prevent this complication. This study was designed to evaluate the Laser-Trach(TM), a new laser-resistant rubber endotracheal tube for use during laser airway surgery. The Laser-Trach endotracheal tubes that were evaluated were size 6.0 mm internal diameter (ID) red rubber endotracheal tubes which had been commercially wrapped by Kendall-Sheridan (Mansfield, Mass.) with copper foil tape and overwrapped with fabric. The fabric layer was saturated with water prior to our tests, as recommended by the manufacturer. The Laser-Trach endotracheal tubes were compared with plain (bare) size 6.0 mm ID Rusch red rubber endotracheal tubes. The tubes under study were positioned horizontally on wet towels in air and had 5 L x min(-1) of oxygen flowing through them. They were subjected to continuous laser radiation at 40 W from either a CO2 or an Nd-YAG laser. The Nd-YAG laser was propagated via a 600-micron fiber bundle. Each laser was directed perpendicularly at the shaft of the endotracheal tube being studied, and its output was continued until a blowtorch fire occurred or 60 seconds had elapsed. Sixty seconds of CO2 laser fire did not ignite any of the eight Laser-Trach endotracheal tubes tested. However, blowtorch ignition of all eight bare rubber tubes tested occurred after 0.87 +/- 0.21 (mean +/- SD) seconds of CO2 laser fire. Nd-YAG laser contact with the Laser-Trach endotracheal tubes caused the perforation and blowtorch ignition of all eight tubes tested after 18.79 +/- 7.83 seconds. This was a significantly (Presistant to the C02 laser. However, this endotracheal tube is not recommended for use with the Nd-YAG laser.

  1. Reliability and criterion-related validity testing (construct) of the Endotracheal Suction Assessment Tool (ESAT©).

    Science.gov (United States)

    Davies, Kylie; Bulsara, Max K; Ramelet, Anne-Sylvie; Monterosso, Leanne

    2018-05-01

    To establish criterion-related construct validity and test-retest reliability for the Endotracheal Suction Assessment Tool© (ESAT©). Endotracheal tube suction performed in children can significantly affect clinical stability. Previously identified clinical indicators for endotracheal tube suction were used as criteria when designing the ESAT©. Content validity was reported previously. The final stages of psychometric testing are presented. Observational testing was used to measure construct validity and determine whether the ESAT© could guide "inexperienced" paediatric intensive care nurses' decision-making regarding endotracheal tube suction. Test-retest reliability of the ESAT© was performed at two time points. The researchers and paediatric intensive care nurse "experts" developed 10 hypothetical clinical scenarios with predetermined endotracheal tube suction outcomes. "Experienced" (n = 12) and "inexperienced" (n = 14) paediatric intensive care nurses were presented with the scenarios and the ESAT© guiding decision-making about whether to perform endotracheal tube suction for each scenario. Outcomes were compared with those predetermined by the "experts" (n = 9). Test-retest reliability of the ESAT© was measured at two consecutive time points (4 weeks apart) with "experienced" and "inexperienced" paediatric intensive care nurses using the same scenarios and tool to guide decision-making. No differences were observed between endotracheal tube suction decisions made by "experts" (n = 9), "inexperienced" (n = 14) and "experienced" (n = 12) nurses confirming the tool's construct validity. No differences were observed between groups for endotracheal tube suction decisions at T1 and T2. Criterion-related construct validity and test-retest reliability of the ESAT© were demonstrated. Further testing is recommended to confirm reliability in the clinical setting with the "inexperienced" nurse to guide decision-making related to endotracheal tube

  2. Control of surface wettability by light illumination: surface wettability control utilizing photo-induced surface reaction of titanium oxide; Hikari de nure wo seigyosuru - sanka chitan no hikari reiki hanno wo riyoshtia nure seigyo gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, T.; Hashimoto, K. [The Universityof Tokyo (Japan)

    1999-02-15

    We report photo-generation of highly hydrophilic surface of titanium dioxide. The photo-induced hydrophilicizing is achieved by photo-generation of Ti{sup 4+} to Ti{sup 3+} at definite sites on the surface, resulting in preferential adsorption of hydroxyl groups on corresponding oxygen vacant sites. We also report the photo-generation of titanium dioxide amphiphilic surface on definite photo illumination condition. The unique character of this surface is ascribed to the microstructure of hydrophilic and oreophilic domain. The hydrophilic or amphiphilic titanium dioxide coating can be applied for antifogging mirror or glass and also self-cleaning paint for various industrial materials. Several commercial applications including antifogging automobile side-view mirror or self-cleaning exterior ceramic tile has been starting to hit the market. (author)

  3. Temporal comparison of ultrasound vs. auscultation and capnography in verification of endotracheal tube placement.

    Science.gov (United States)

    Pfeiffer, P; Rudolph, S S; Børglum, J; Isbye, D L

    2011-11-01

    This study compared the time consumption of bilateral lung ultrasound with auscultation and capnography for verifying endotracheal intubation. A prospective, paired, and investigator-blinded study carried out in the operating theatre. Twenty-five adult patients requiring endotracheal intubation were included. During intubation, transtracheal ultrasound was performed to visualize passage of the endotracheal tube. During bag ventilation, bilateral lung ultrasound was performed for the detection of lung sliding as a sign of ventilation simultaneous with capnography and auscultation of the epigastrium and chest. Primary outcome measure was time difference to confirmed endotracheal intubation between ultrasound and auscultation alone. Secondary outcome measure was time difference between ultrasound and auscultation combined with capnography. Both methods verified endotracheal tube placement in all patients. In 68% of patients, endotracheal tube placement was visualized by real-time transtracheal ultrasound. Comparing ultrasound with the combination of auscultation and capnography, there was a significant difference between the two methods. Median time for ultrasound was 40 s [interquartile range (IQR) 35-48 s] vs. 48 s (IQR 45-53 s), P auscultation alone. Median time for auscultation alone was 42 s (IQR 37-47 s), P = 0.6, with a mean difference of -0.88 s in favour of ultrasound (95% CI -4.2-2.5 s). Verification of endotracheal tube placement with ultrasound is as fast as auscultation alone and faster than the standard method of auscultation and capnography. © 2011 The Authors. Acta Anaesthesiologica Scandinavica © 2011 The Acta Anaesthesiologica Scandinavica Foundation.

  4. Geospatial Analysis of Pediatric EMS Run Density and Endotracheal Intubation

    Directory of Open Access Journals (Sweden)

    Matthew Hansen

    2016-09-01

    Full Text Available Introduction: The association between geographic factors, including transport distance, and pediatric emergency medical services (EMS run clustering on out-of-hospital pediatric endotracheal intubation is unclear. The objective of this study was to determine if endotracheal intubation procedures are more likely to occur at greater distances from the hospital and near clusters of pediatric calls. Methods: This was a retrospective observational study including all EMS runs for patients less than 18 years of age from 2008 to 2014 in a geographically large and diverse Oregon county that includes densely populated urban areas near Portland and remote rural areas. We geocoded scene addresses using the automated address locator created in the cloud-based mapping platform ArcGIS, supplemented with manual address geocoding for remaining cases. We then use the Getis-Ord Gi spatial statistic feature in ArcGIS to map statistically significant spatial clusters (hot spots of pediatric EMS runs throughout the county. We then superimposed all intubation procedures performed during the study period on maps of pediatric EMS-run hot spots, pediatric population density, fire stations, and hospitals. We also performed multivariable logistic regression to determine if distance traveled to the hospital was associated with intubation after controlling for several confounding variables. Results: We identified a total of 7,797 pediatric EMS runs during the study period and 38 endotracheal intubations. In univariate analysis we found that patients who were intubated were similar to those who were not in gender and whether or not they were transported to a children’s hospital. Intubated patients tended to be transported shorter distances and were older than non-intubated patients. Increased distance from the hospital was associated with reduced odds of intubation after controlling for age, sex, scene location, and trauma system entry status in a multivariate logistic

  5. Management of avulsed permanent maxillary central incisors during endotracheal intubation

    Directory of Open Access Journals (Sweden)

    Ritesh R Kalaskar

    2016-01-01

    Full Text Available Avulsion is serious injury that may encounter during endotracheal intubation and its management often presents a challenge. Replantation of the avulsed tooth can restore esthetic appearance and occlusal function shortly after the injury. The present article describes the management of air-dried maxillary permanent incisors that have been avulsed due to direct laryngoscopy during the induction of general anesthesia for tonsillectomy procedure. The replanted maxillary central incisors had maintained its function and esthetic for 1 year after replantation. Children in a mixed dentition phase are high-risk group children for traumatic dental injury during laryngoscopy; therefore, Anesthetic Departments should have local protocols to refer patients for dental treatment postoperatively in the event of trauma.

  6. Endotracheal tube defects: Hidden causes of airway obstruction

    Directory of Open Access Journals (Sweden)

    Sofi Khalid

    2010-01-01

    Full Text Available Manufacturing defects of endotracheal tube (ETT are still encountered in anesthesia practice. Many such defects go unnoticed during routine inspection prior to their use. Such defects in ETT may lead to partial or complete airway obstruction in an intubated patient. We report a case of partial airway obstruction with a prepacked, single use, uncuffed ETT due to a manufacturing defect in the form of a plastic meniscus at the distal end of the tube. This case report highlights the significance of standard monitoring of ventilation and the role of a vigilant clinician in detecting such defects in avoiding critical events as can arise from the use of such defective ETTs. It also emphasizes the need for double checking ETTs prior to their use.

  7. Lack of agreement and trending ability of the endotracheal cardiac output monitor compared with thermodilution

    DEFF Research Database (Denmark)

    Møller-Sørensen, H; Hansen, K L; Ostergaard, M

    2012-01-01

    BACKGROUND: Minimally invasive monitoring systems of central haemodynamics are gaining increasing popularity. The present study investigated the precision of the endotracheal cardiac output monitor (ECOM) system and its agreement with pulmonary artery catheter thermodilution (PAC TD) for measuring...

  8. Long-term outcome of conventional endotracheal tube balloon dilation of tracheal stenosis in a dog

    OpenAIRE

    Kahane, Nili; Segev, Gilad

    2014-01-01

    This report describes a successful dilation of tracheal stenosis in a 16-year-old dog using a conventional endotracheal tube balloon. This technique should be considered as palliative treatment when owners decline other therapeutic options.

  9. Long-term outcome of conventional endotracheal tube balloon dilation of tracheal stenosis in a dog.

    Science.gov (United States)

    Kahane, Nili; Segev, Gilad

    2014-01-01

    This report describes a successful dilation of tracheal stenosis in a 16-year-old dog using a conventional endotracheal tube balloon. This technique should be considered as palliative treatment when owners decline other therapeutic options.

  10. Experience of monitoring the recurrent laryngeal nerve in thyroid surgery with endotracheal intubation

    Directory of Open Access Journals (Sweden)

    Liang Feng

    2017-01-01

    Full Text Available Purpose:To analysis clinical experience of applying recurrent laryngeal monitoring endotracheal tube (NIM EMG Endotracheal Tube in the surgery of thyroid. Method: A retrospective analysis of 84 patients who underwent endotracheal intubation laryngeal nerve monitoring by thyroid surgery in the Chinese-Japanese Friendship Hospital of Jilin University from March to December in 2015. To summarize the experience of intubation with NIM EMG Endotracheal Tube. Result 77 (91.7%had initial intubation achievement in the 84 patients.FROM the 77 cases we had gotten s atisfactory nerve monitoring signal.Whereas there are 7 cases (8.3% appear abnormal EMG or signal missing, in the 7 cases there is one which being intubated too deep, 3 cases which being intubated too shallow and 3 cases with malrotation intubation.Conclusion: We got the satisfactory signals after adjust1ing the tube by using the visual laryngoscope.

  11. Real-time tracheal ultrasonography for confirmation of endotracheal tube placement during cardiopulmonary resuscitation.

    Science.gov (United States)

    Chou, Hao-Chang; Chong, Kah-Meng; Sim, Shyh-Shyong; Ma, Matthew Huei-Ming; Liu, Shih-Hung; Chen, Nai-Chuan; Wu, Meng-Che; Fu, Chia-Ming; Wang, Chih-Hung; Lee, Chien-Chang; Lien, Wan-Ching; Chen, Shyr-Chyr

    2013-12-01

    This study aimed to evaluate the accuracy of tracheal ultrasonography for assessing endotracheal tube position during cardiopulmonary resuscitation (CPR). We performed a prospective observational study of patients undergoing emergency intubation during CPR. Real-time tracheal ultrasonography was performed during the intubation with the transducer placed transversely just above the suprasternal notch, to assess for endotracheal tube positioning and exclude esophageal intubation. The position of trachea was identified by a hyperechoic air-mucosa (A-M) interface with posterior reverberation artifact (comet-tail artifact). The endotracheal tube position was defined as endotracheal if single A-M interface with comet-tail artifact was observed. Endotracheal tube position was defined as intraesophageal if a second A-M interface appeared, suggesting a false second airway (double tract sign). The gold standard of correct endotracheal intubation was the combination of clinical auscultation and quantitative waveform capnography. The main outcome was the accuracy of tracheal ultrasonography in assessing endotracheal tube position during CPR. Among the 89 patients enrolled, 7 (7.8%) had esophageal intubations. The sensitivity, specificity, positive predictive value, and negative predictive value of tracheal ultrasonography were 100% (95% confidence interval [CI]: 94.4-100%), 85.7% (95% CI: 42.0-99.2%), 98.8% (95% CI: 92.5-99.0%) and 100% (95% CI: 54.7-100%), respectively. Positive and negative likelihood ratios were 7.0 (95% CI: 1.1-43.0) and 0.0, respectively. Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during CPR without the need for interruption of chest compression. Tracheal ultrasonography in resuscitation management may serve as a powerful adjunct in trained hands. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  12. Opportunities in the electrowinning of molten titanium from titanium dioxide

    CSIR Research Space (South Africa)

    Van Vuuren, DS

    2005-10-01

    Full Text Available used, the following forms of titanium are produced: titanium sponge, sintered electrode sponge, powder, molten titanium, electroplated titanium, hydride powder, and vapor-phase depos- ited titanium. Comparing the economics of alter- native...-up for producing titanium via the Kroll process is approximately as follows: ilmenite ($0.27/kg titanium sponge); titanium slag ($0.75/kg titanium sponge); TiCl4 ($3.09/kg titanium sponge); titanium sponge raw materials costs ($5.50/kg titanium sponge); total...

  13. Ultrasonography for Proper Endotracheal Tube Placement Confirmation in Out-of-hospital Cardiac Arrest Patients: Two-center Experience

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Conclusion: Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during cardiopulmonary resuscitation without the need for interruption of chest compression.

  14. 18-gauge needle cap as adjunct to prevent kinking of endotracheal tube.

    Science.gov (United States)

    Chan, Fuan Chiang; Kawamoto, Henry K; Bradley, James P

    2012-11-01

    A self-retaining Dingman mouth retractor is widely used to keep the mouth open during cleft palate and intraoral surgery. The airway is at risk of being crushed or occluded as the gag (tongue plate) of the Dingman mouth retractor is being pushed against the endotracheal tube.Kinking of the endotracheal tube between the teeth and Dingman mouth retractor has been reported even with the oral Ring-Adair-Elwyn or flexometallic or armored endotracheal tubes. To minimize kinking of the endotracheal tube and its consequent complications, we routinely insert an 18-gauge needle cap at the potential space between the teeth and the tongue plate (gag) of the Dingman mouth retractor, which is situated lateral to the endotracheal tube. In our experience of approximately 5000 intraoral cases using a Dingman mouth retractor and 18-gauge needle cap, we have not had any tooth avulsion or aspiration of the 18-gauge foreign body while maintaining a consistent and secured airway during cleft palate and intraoral surgery.

  15. Tracheal palpation to assess endotracheal tube depth: an exploratory study.

    Science.gov (United States)

    McKay, William P; Klonarakis, Jim; Pelivanov, Vladko; O'Brien, Jennifer M; Plewes, Chris

    2014-03-01

    Correct placement of the endotracheal tube (ETT) occurs when the distal tip is in mid-trachea. This study compares two techniques used to place the ETT at the correct depth during intubation: tracheal palpation vs placement at a fixed depth at the patient's teeth. With approval of the Research Ethics Board, we recruited American Society of Anesthesiologists physical status I-II patients scheduled for elective surgery with tracheal intubation. Clinicians performing the tracheal intubations were asked to "advance the tube slowly once the tip is through the cords". An investigator palpated the patient's trachea with three fingers spread over the trachea from the larynx to the sternal notch. When the ETT tip was felt in the sternal notch, the ETT was immobilized and its position was determined by fibreoptic bronchoscopy. The position of the ETT tip was compared with our hospital standard, which is a depth at the incisors or gums of 23 cm for men and 21 cm for women. The primary outcome was the incidence of correct placement. Correct placement of the ETT was defined as a tip > 2.5 cm from the carina and > 3.5 cm below the vocal cords. Movement of the ETT tip was readily palpable in 77 of 92 patients studied, and bronchoscopy was performed in 85 patients. Placement by tracheal palpation resulted in more correct placements (71 [77%]; 95% confidence interval [CI] 74 to 81) than hospital standard depth at the incisors or gums (57 [61%]; 95% CI 58 to 66) (P = 0.037). The mean (SD) placement of the ETT tip in palpable subjects was 4.1 (1.7) cm above the carina, 1.9 cm (1.5-2.3 cm) below the ideal mid-tracheal position. Tracheal palpation requires no special equipment, takes only a few seconds to perform, and may improve ETT placement at the correct depth. Further studies are warranted.

  16. A Novel Artificial Intelligence System for Endotracheal Intubation.

    Science.gov (United States)

    Carlson, Jestin N; Das, Samarjit; De la Torre, Fernando; Frisch, Adam; Guyette, Francis X; Hodgins, Jessica K; Yealy, Donald M

    2016-01-01

    Adequate visualization of the glottic opening is a key factor to successful endotracheal intubation (ETI); however, few objective tools exist to help guide providers' ETI attempts toward the glottic opening in real-time. Machine learning/artificial intelligence has helped to automate the detection of other visual structures but its utility with ETI is unknown. We sought to test the accuracy of various computer algorithms in identifying the glottic opening, creating a tool that could aid successful intubation. We collected a convenience sample of providers who each performed ETI 10 times on a mannequin using a video laryngoscope (C-MAC, Karl Storz Corp, Tuttlingen, Germany). We recorded each attempt and reviewed one-second time intervals for the presence or absence of the glottic opening. Four different machine learning/artificial intelligence algorithms analyzed each attempt and time point: k-nearest neighbor (KNN), support vector machine (SVM), decision trees, and neural networks (NN). We used half of the videos to train the algorithms and the second half to test the accuracy, sensitivity, and specificity of each algorithm. We enrolled seven providers, three Emergency Medicine attendings, and four paramedic students. From the 70 total recorded laryngoscopic video attempts, we created 2,465 time intervals. The algorithms had the following sensitivity and specificity for detecting the glottic opening: KNN (70%, 90%), SVM (70%, 90%), decision trees (68%, 80%), and NN (72%, 78%). Initial efforts at computer algorithms using artificial intelligence are able to identify the glottic opening with over 80% accuracy. With further refinements, video laryngoscopy has the potential to provide real-time, direction feedback to the provider to help guide successful ETI.

  17. Phenol Photocatalytic Degradation by Advanced Oxidation Process under Ultraviolet Radiation Using Titanium Dioxide

    Directory of Open Access Journals (Sweden)

    Ali Nickheslat

    2013-01-01

    Full Text Available Background. The main objective of this study was to examine the photocatalytic degradation of phenol from laboratory samples and petrochemical industries wastewater under UV radiation by using nanoparticles of titanium dioxide coated on the inner and outer quartz glass tubes. Method. The first stage of this study was conducted to stabilize the titanium dioxide nanoparticles in anatase crystal phase, using dip-coating sol-gel method on the inner and outer surfaces of quartz glass tubes. The effect of important parameters including initial phenol concentration, TiO2 catalyst dose, duration of UV radiation, pH of solution, and contact time was investigated. Results. In the dip-coat lining stage, the produced nanoparticles with anatase crystalline structure have the average particle size of 30 nm and are uniformly distributed over the tube surface. The removal efficiency of phenol was increased with the descending of the solution pH and initial phenol concentration and rising of the contact time. Conclusion. Results showed that the light easily passes through four layers of coating (about 105 nm. The highest removal efficiency of phenol with photocatalytic UV/TiO2 process was 50% at initial phenol concentration of 30 mg/L, solution pH of 3, and 300 min contact time. The comparison of synthetic solution and petrochemical wastewater showed that at same conditions the phenol removal efficiency was equal.

  18. Whistle from Afar: A Case of Endotracheal Metastasis in Papillary Thyroid Cancer

    Directory of Open Access Journals (Sweden)

    Bitoti Chattopadhyay

    2012-01-01

    Full Text Available Endotracheal metastasis is a rare situation, usually associated with malignancies of breast and gastrointestinal tract, specially colon. Papillary carcinoma of thyroid commonly disseminates through lymphatic channels and tracheal involvement through vascular route is rarely reported. Here, we report a case of tracheal metastasis from papillary carcinoma of thyroid. The patient responded to external beam radiation therapy with cobalt 60 beams in a dose of 44 Gy followed by a 16 Gy boost. The patient is under followup and is presently asymptomatic. This paper adds to the repertoire of evidence in treatment of endotracheal metastasis.

  19. Deep versus shallow suction of endotracheal tubes in ventilated neonates and young infants.

    Science.gov (United States)

    Gillies, Donna; Spence, Kaye

    2011-07-06

    Mechanical ventilation is commonly used in Neonatal Intensive Care Units to assist breathing in a variety of conditions. Mechanical ventilation is achieved through the placement of an endotracheal tube (ETT) which is left in-situ. The ETT is suctioned to prevent a build-up of secretions and blockage of the airway. Methods of suctioning the endotracheal tube vary according to institutional practice and the individual clinician performing the task. The depth of suctioning is one of these variables. The catheter may be passed to the tip of the ETT or beyond the tip into the trachea or bronchi to facilitate removal of secretions. However, trauma to the lower airways may result from the suction catheter being passed into the airway beyond the tip of the endotracheal tube. To compare the effectiveness and complications of deep (catheter passed beyond the tip of the ETT) versus shallow (catheter passed to length of ETT only) suctioning of the endotracheal tube in ventilated infants. In this first update the searches were expanded to the Cochrane Central Register of Controlled Trials (The Cochrane Library, March 30), MEDLINE (from January 1966 to May 30 2011), CINAHL (from 1982 to May 30 2011) and EMBASE (1980 to May 2011) using text words and subject headings relevant to endotracheal suctioning. There were no language restrictions. Controlled trials using random or quasi-random allocation of neonates receiving ventilatory support via an endotracheal tube to either deep or shallow endotracheal suctioning. The updated search resulted in 149 potentially relevant references. Two of the studies from this search were identified as potentially relevant. We included one of the potentially relevant studies and the other was excluded because it did not fit the inclusion criteria. One small crossover trial (n = 27) of shallow versus deep suctioning met the criteria for inclusion in this review. The reported outcomes were oxygen saturation and heart rate, during and after suctioning

  20. Complete Obstruction of Endotracheal Tube in an Infant with a Retropharyngeal and Anterior Mediastinal Abscess

    Directory of Open Access Journals (Sweden)

    Dennis B. Thapa

    2017-01-01

    Full Text Available Intraoperative ventilatory failure is not an uncommon complication; however, acute endotracheal obstruction by a foreign body or blood clot can be difficult to quickly discriminate from other causes. Once the diagnosis is made, quick action is needed to restore ventilation. The ultimate solution is to exchange the endotracheal tube; however, there can be other ways of resolving this in situations where reintubation would be difficult or unsafe. This case report discusses such an event in an infant with multiple airway challenges including a retropharyngeal and anterior mediastinal abscess. We have also formulated a pathway based on various case reports involving complete ETT obstruction.

  1. Complete Obstruction of Endotracheal Tube in an Infant with a Retropharyngeal and Anterior Mediastinal Abscess.

    Science.gov (United States)

    Thapa, Dennis B; Greene, Nathaniel H; Udani, Andrea G

    2017-01-01

    Intraoperative ventilatory failure is not an uncommon complication; however, acute endotracheal obstruction by a foreign body or blood clot can be difficult to quickly discriminate from other causes. Once the diagnosis is made, quick action is needed to restore ventilation. The ultimate solution is to exchange the endotracheal tube; however, there can be other ways of resolving this in situations where reintubation would be difficult or unsafe. This case report discusses such an event in an infant with multiple airway challenges including a retropharyngeal and anterior mediastinal abscess. We have also formulated a pathway based on various case reports involving complete ETT obstruction.

  2. Surface wettability control by titanium dioxide photo-induced reaction. Super-hydrophilic properties; Sanka chitan ni yoru hikari reiki shinsuika gijutsu. Hikari shokubai chosinsuisei

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, T. [The University of Tokyo, Tokyo (Japan). Research Center for Advanced Science and Technology

    1999-05-01

    Hydrophilicity results when the surface of titanium dioxide is reduced for the specified oxygen to be replaced by hydroxyl groups. The ease with which such a structural change occurs is subject to variation between titanium dioxide crystal surfaces, and is dependent greatly on the atmosphere. No hydrophilic trend is observed in an atmosphere of oxygen only without moisture and, in darkness without light, hydrophobicity occurs early. Although the contacta angle titanium dioxide with water with stability is not known, yet it is presumed, on the analogy of the case of strontium titanate, that it is in the range of 20-40 degrees. A hydrophilic trend below the range is attrributed to structural changes. The control of surface wettability is one of the basic tasks to fulfill in various kinds of mechanisms and manufacturing processes. The technology of wettability control using a titanium dioxide coating which is quite durable will be applied not only to functions involving defogging, dripproof, and self-cleaning, but also to the control of heat transmission in the mechanism and to the bonding process. (NEDO)

  3. Surface wettability control by titanium dioxide photo-induced reaction. Super-hydrophilic properties. Sanka chitan ni yoru hikari reiki shinsuika gijutsu. Hikari shokubai chosinsuisei

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, T. (The University of Tokyo, Tokyo (Japan). Research Center for Advanced Science and Technology)

    1999-05-01

    Hydrophilicity results when the surface of titanium dioxide is reduced for the specified oxygen to be replaced by hydroxyl groups. The ease with which such a structural change occurs is subject to variation between titanium dioxide crystal surfaces, and is dependent greatly on the atmosphere. No hydrophilic trend is observed in an atmosphere of oxygen only without moisture and, in darkness without light, hydrophobicity occurs early. Although the contacta angle titanium dioxide with water with stability is not known, yet it is presumed, on the analogy of the case of strontium titanate, that it is in the range of 20-40 degrees. A hydrophilic trend below the range is attrributed to structural changes. The control of surface wettability is one of the basic tasks to fulfill in various kinds of mechanisms and manufacturing processes. The technology of wettability control using a titanium dioxide coating which is quite durable will be applied not only to functions involving defogging, dripproof, and self-cleaning, but also to the control of heat transmission in the mechanism and to the bonding process. (NEDO)

  4. Titanium and titanium alloys: fundamentals and applications

    National Research Council Canada - National Science Library

    Leyens, C; Peters, M

    2003-01-01

    ... number of titanium alloys have paved the way for light metals to vastly expand into many industrial applications. Titanium and its alloys stand out primarily due to their high specific strength and excellent corrosion resistance, at just half the weight of steels and Ni-based superalloys. This explains their early success in the aerospace and the...

  5. Evaluation of Endotracheal Tube Scraping on Airway Resistance.

    Science.gov (United States)

    Scott, J Brady; Dubosky, Meagan N; Vines, David L; Sulaiman, Adewunmi S; Jendral, Kyle R; Singh, Gagan; Patel, Ankeet; Kaplan, Carl A; Gurka, David P; Balk, Robert A

    2017-11-01

    Spontaneous breathing trials (SBTs) are used to assess the readiness for discontinuation of mechanical ventilation. When airway resistance (R aw ) is elevated, the imposed work of breathing can lead to prolongation of mechanical ventilation. Biofilm and mucus build-up within the endotracheal tube (ETT) can increase R aw . Scraping the ETT can remove the biofilm build-up and decrease mechanical R aw . The primary aim of this study was to evaluate the impact of ETT scraping on R aw . The secondary aim was to determine whether decreasing R aw would impact subsequent SBT success. Intubated, mechanically ventilated subjects were enrolled if they failed an SBT and had an R aw of > 10 cm H 2 O/L/s. SBT failure was based on institutional guidelines, and R aw was calculated by subtracting the difference between the measured peak and plateau pressures using a square flow waveform with an inspiratory flow set at 60 L/min. The endOclear device was inserted into the ETT and withdrawn per manufacturer's guidelines. Scraping was repeated until the ETT was cleared. Change in R aw was compared pre- and post-ETT scraping using a paired t test. A Mann-Whitney U test evaluated the difference in percentage change in R aw between SBT groups. Twenty-nine subjects completed the study. The mean pre- and post-ETT scraping R aw values were 15.17 ± 3.83 and 12.05 ± 3.19 cm H 2 O/L/s, respectively ( P < .001). Subsequent SBT success was 48%; however, there was no difference in percentage change in R aw between subsequent passed SBT (18.61% [interquartile range 8.90-33.93%]) and failed SBT (23.88% [interquartile range 0.00-34.80%]), U = 78.5, z = -0.284, P = .78. No adverse events were noted with ETT scraping. This study demonstrated that ETT scraping can reduce R aw . The decrease in R aw post-ETT scraping did not affect subsequent SBT success. Copyright © 2017 by Daedalus Enterprises.

  6. Obstruction of endotracheal tube with relevant respiratory acidosis during pediatric cardiac surgery

    NARCIS (Netherlands)

    Morei, N.M.; Mungroop, H. E.; Michielon, Guido; Scheeren, Thomas

    2014-01-01

    We describe a case of pediatric cardiac surgery in a 21- days old baby, in whom a nasal endotracheal tube (ETT) was inserted. At the end of surgery both ventilatory pressures and end-tidal CO2 increased suggesting airway obstruction. Suctioning of the ETT lumen did not relieve the problem, only ETT

  7. Sphingosine Prevents Bacterial Adherence to Endotracheal Tubes: A Novel Mechanism to Prevent Ventilator-Associated Pneumonia

    Science.gov (United States)

    2016-06-21

    and resists the antimicrobial properties of the host defense” [9]. Bacterial adhesion is the first step in biofilm formation [10]; thus, prevention...ETTs. Future in vitro and animal studies are necessary to establish the safety of sphingolipid coatings, and future randomized clinical trials will...SUBJECT TERMS Ventilator-associated pneumonia, VAP, Gram-negative, bacteria, endotracheal tubes, sphingosine, antimicrobial coating 16. SECURITY

  8. SUPRAGLOTTIC JET VENTILATION VERSUS CONVENTIONAL ENDOTRACHEAL VENTILATION IN MINOR LARYNGEAL SURGERIES

    Directory of Open Access Journals (Sweden)

    Illendual Upendranath

    2016-08-01

    Full Text Available Any attempt at intubation will cause many cardiovascular responses and the major concern during this time is to attenuate the same. Similar response is seen during procedures on Larynx in microlaryngeal surgery which produces an intense cardiovascular stimulation during suspension laryngoscopy and intubation. AIM OF STUDY Supraglottic jet ventilation versus conventional endotracheal ventilation in minor laryngeal surgeries. To evaluate the haemodynamic response in supraglottic jet ventilation and conventional intubation in minor laryngeal surgeries. METHODS Patients were randomised to 2 Groups: 30 patients in each group; Group A - in whom supraglottic jet ventilation was planned and Group B - in whom endotracheal intubation was planned. RESULT The haemodynamic response in terms of increase in MAP and HR is significantly more with endotracheal intubation than with supraglottic jet ventilation. CONCLUSION Our study showed that supraglottic jet ventilation showed a better haemodynamic stability when compared to conventional endotracheal intubation in patients undergoing minor laryngeal surgeries. Statistical scores were also in favour of the patients treated with supraglottic jet ventilation based on the p values.

  9. Endotracheal temperature and humidity measurements in laryngectomized patients: intra- and inter-patient variability

    NARCIS (Netherlands)

    Scheenstra, R.J.; Muller, S.H.; Vincent, A.; Sinaasappel, M.; Zuur, J.K.; Hilgers, F.J.M.

    2009-01-01

    This study assesses intra- and inter-patient variability in endotracheal climate (temperature and humidity) and effects of heat and moister exchangers (HME) in 16 laryngectomized individuals, measured repeatedly (N = 47). Inhalation Breath Length (IBL) was 1.35 s without HME and 1.05 s with HME (P <

  10. Endotracheal temperature and humidity measurements in laryngectomized patients: intra- and inter-patient variability

    NARCIS (Netherlands)

    Scheenstra, R. J.; Muller, S. H.; Vincent, A.; Sinaasappel, M.; Zuur, J. K.; Hilgers, Frans J. M.

    2009-01-01

    This study assesses intra- and inter-patient variability in endotracheal climate (temperature and humidity) and effects of heat and moister exchangers (HME) in 16 laryngectomized individuals, measured repeatedly (N = 47). Inhalation Breath Length (IBL) was 1.35 s without HME and 1.05 s with HME (P

  11. Distribution of endotracheally instilled surfactant protein SP-C in lung-lavaged rabbits.

    NARCIS (Netherlands)

    Bambang Oetomo, Sidarto; de Leij, Louis; Curstedt, T; ter Haar, J G; Schoots, Coenraad; Wildevuur, Charles; Okken, Albert

    In lung-lavaged surfactant-deficient rabbits (n = 6) requiring artificial ventilation, porcine surfactant was instilled endotracheally. This resulted in improvement of lung function so that the animals could be weaned off artificial ventilation. The animals were killed 4 1/2 h after surfactant

  12. Verification of endotracheal intubation in obese patients - temporal comparison of ultrasound vs. auscultation and capnography

    DEFF Research Database (Denmark)

    Pfeiffer, P; Bache, Stefan Holst; Isbye, D L

    2012-01-01

    Ultrasound (US) may have an emerging role as an adjunct in verification of endotracheal intubation. Obtaining optimal US images in obese patients is generally regarded more difficult than for other patients. This study compared the time consumption of bilateral lung US with auscultation and capno...

  13. Management of dogs and cats with endotracheal tube tracheal foreign bodies

    Science.gov (United States)

    Nutt, Laura K.; Webb, Jinelle A.; Prosser, Kirsten J.; Defarges, Alice

    2014-01-01

    Two cats and 3 dogs were treated for an endotracheal tube tracheal foreign body (ETFB) during recovery from general anesthesia. Bronchoscopy was used to remove the ETFB. Animals were clinically normal at discharge. While rare, ETFB can occur upon recovery from anesthesia. Bronchoscopy is an effective way to remove ETFB. PMID:24891640

  14. Verification of endotracheal intubation in obese patients - temporal comparison of ultrasound vs. auscultation and capnography.

    Science.gov (United States)

    Pfeiffer, P; Bache, S; Isbye, D L; Rudolph, S S; Rovsing, L; Børglum, J

    2012-05-01

    Ultrasound (US) may have an emerging role as an adjunct in verification of endotracheal intubation. Obtaining optimal US images in obese patients is generally regarded more difficult than for other patients. This study compared the time consumption of bilateral lung US with auscultation and capnography for verifying endotracheal intubation in obese patients. A prospective, paired and investigator-blinded study performed in the operating theatre. Twenty-four adult patients requiring endotracheal intubation for bariatric surgery were included. During post-intubation bag ventilation, bilateral lung US was performed for detection of lungsliding indicating lung ventilation simultaneous with capnography and auscultation of epigastrium and chest. Primary outcome measure was the time difference to confirmed endotracheal intubation between US and auscultation alone. The secondary outcome measure was time difference between US and auscultation combined with capnography. Both methods verified endotracheal tube placement in all patients. No significant difference was found between US compared with auscultation alone. Median time for verification by auscultation alone was 47.5 s [interquartile (IQR) 40-51 s], with a mean difference of -0.3 s in favor of US (95% confidence interval -3.5-2.9 s) P = 0.87. Comparing US with the combination of auscultation and capnography, there was a significant difference between the two methods. Median time for verification by US was 43 s (IQR 40-51 s) vs. 55 s (IQR 46-65 s), P auscultation alone and faster than the standard method of auscultation and capnography. © 2012 The Authors. Acta Anaesthesiologica Scandinavica © 2012 The Acta Anaesthesiologica Scandinavica Foundation.

  15. [The role of endotracheal aspiration in the diagnosis of ventilator associated pneumonia].

    Science.gov (United States)

    Gürgün, Alev; Korkmaz Ekren, Pervin; Bacakoğlu, Feza; Başoğlu, Ozen Kaçmaz; Dirican, Nigar; Aydemir, Şöhret; Nart, Deniz; Sayıner, Abdullah

    2013-01-01

    Ventilator associated pneumonia (VAP) is one of the most important causes of mortality in patients treated with invasive mechanical ventilation (IMV) in intensive care unit (ICU). Microbiological examinations are required as clinical and radiological findings are usually insufficient in the diagnosis. Twenty four patients who were receiving IMV because of respiratory failure, had a Clinical Pulmonary Infection Score (CPIS) of ≥ 6 in the follow-up and died with the suspicion of VAP were enrolled in our study. Six patients were excluded as post-mortem biopsy could not be performed. The patients who had pre-mortem CPIS ≥ 6, in whom a causative organism was identified from the culture of post-mortem lung biopsy and/or histopathological examination of lung biopsy was compatible with pneumonia were diagnosed as VAP. In the 18 patients in whom a post-mortem lung biopsy was performed, quantitative culture results of endotracheal aspirate performed 48 hours prior to death were compared with microbiological and histopathological results of post-mortem lung biopsy specimens, and the role of endotracheal aspirate in the diagnosis of VAP was evaluated retrospectively. Out of 18 patients (12 men, mean age 67.0 ± 13.0 years) included in the study, 11 (61.1%) were diagnosed as VAP. The quantitative culture of endotracheal aspirate was positive in 9 (81.8%) out of 11 patients diagnosed as VAP. The sensitivity, specificity, positive and negative predictive values of endotracheal aspirate culture for identifying VAP were found to be 81.8%, 14.3%, 60.0% and 33.3%, respectively. Our study shown that quantitative culture of endotracheal aspirate is a practical and reliable method that can be used for the diagnosis of VAP in patients receiving IMV in ICU and having CPIS ≥ 6.

  16. Sealing glasses for titanium and titanium alloys

    Science.gov (United States)

    Brow, Richard K.; McCollister, Howard L.; Phifer, Carol C.; Day, Delbert E.

    1997-01-01

    Barium lanthanoborate sealing-glass compositions are provided comprising various combinations (in terms of mole-%) of boron oxide (B.sub.2 O.sub.3), barium oxide (BaO), lanthanum oxide (La.sub.2 O.sub.3), and at least one other oxide selected from the group consisting of aluminum oxide (Al.sub.2 O.sub.3), calcium oxide (CaO), lithium oxide (Li.sub.2 O), sodium oxide (Na.sub.2 O), silicon dioxide (SiO.sub.2), or titanium dioxide (TiO.sub.2). These sealing-glass compositions are useful for forming hermetic glass-to-metal seals with titanium and titanium alloys having an improved aqueous durability and favorable sealing characteristics. Examples of the sealing-glass compositions are provided having coefficients of thermal expansion about that of titanium or titanium alloys, and with sealing temperatures less than about 900.degree. C., and generally about 700.degree.-800.degree. C. The barium lanthanoborate sealing-glass compositions are useful for components and devices requiring prolonged exposure to moisture or water, and for implanted biomedical devices (e.g. batteries, pacemakers, defibrillators, pumps).

  17. Endotracheal intubation: application of virtual reality to emergency medical services education.

    Science.gov (United States)

    Mayrose, James; Myers, Jeffrey W

    2007-01-01

    Virtual reality simulation has been identified as an emerging educational tool with significant potential to enhance teaching of residents and students in emergency clinical encounters and procedures. Endotracheal intubation represents a critical procedure for emergency care providers. Current methods of training include working with cadavers and mannequins, which have limitations in their representation of reality, ethical concerns, and overall availability with access, cost, and location of models. This paper will present a human airway simulation model designed for tracheal intubation and discuss the aspects that lend itself to use as an educational tool. This realistic and dynamic model is used to teach routine intubations, while future models will include more difficult airway management scenarios. This work provides a solid foundation for future versions of the intubation simulator, which will incorporate two haptic devices to allow for simultaneous control of the laryngoscope blade and endotracheal tube.

  18. Comparison of expandable endotracheal stents in the treatment of surgically induced piglet tracheomalacia.

    Science.gov (United States)

    Mair, E A; Parsons, D S; Lally, K P; Van Dellen, A F

    1991-09-01

    Present surgical alternatives for pediatric tracheobronchomalacia are limited and associated with many potentially undesirable complications. The feasibility of different intraluminal expandable endotracheal stents for the treatment of surgically induced tracheomalacia was analyzed in 27 piglets. A potentially fatal tracheomalacia was surgically created. Either a stainless steel "zig-zag" stent or a woven polymeric stent was then implanted. Tracheal patency, mucosal function, histopathologic respiratory tract changes, and effects of the stent on esophageal motility were evaluated over a 16-week period. Piglets with steel stents uniformly experienced intense inflammation leading to tracheal dysfunction and death. Piglets with polymeric stents experienced minimal respiratory symptoms. Expandable polymeric endotracheal stents alleviate surgically induced piglet tracheomalacia, were easy to insert, allowed for tracheal growth, and reduced the need for high-risk surgical procedures with prolonged ventilatory support.

  19. Classification of titanium dioxide

    International Nuclear Information System (INIS)

    Macias B, L.R.; Garcia C, R.M.; Maya M, M.E.; Ita T, A. De; Palacios G, J.

    2002-01-01

    In this work the X-ray diffraction (XRD), Scanning Electron Microscopy (Sem) and the X-ray Dispersive Energy Spectroscopy techniques are used with the purpose to achieve a complete identification of phases and mixture of phases of a crystalline material as titanium dioxide. The problem for solving consists of being able to distinguish a sample of titanium dioxide being different than a titanium dioxide pigment. A standard sample of titanium dioxide with NIST certificate is used, which indicates a purity of 99.74% for the TiO 2 . The following way is recommended to proceed: a)To make an analysis by means of X-ray diffraction technique to the sample of titanium dioxide pigment and on the standard of titanium dioxide waiting not find differences. b) To make a chemical analysis by the X-ray Dispersive Energy Spectroscopy via in a microscope, taking advantage of the high vacuum since it is oxygen which is analysed and if it is concluded that the aluminium oxide appears in a greater proportion to 1% it is established that is a titanium dioxide pigment, but if it is lesser then it will be only titanium dioxide. This type of analysis is an application of the nuclear techniques useful for the tariff classification of merchandise which is considered as of difficult recognition. (Author)

  20. Comparison of an Endotracheal Cardiac Output Monitor to a Pulmonary Artery Catheter

    Science.gov (United States)

    2017-12-04

    8217-’ ’ ,, Background In combat, initial resuscitation and life saving measures are in itiated by securing a patent airway and administering fluid therapy. Wh...ile methods of fluid resuscitation remain controversial , maintenance of a patent airway and hemodynamic stabi lity as indicated by invasive...monito ri ng can influence the overall outcome of an injured individual. A patent airway may be maintained via an endotracheal tube . The use of

  1. A Randomized Comparison of In-hospital Rescuer Positions for Endotracheal Intubation in a Difficult Airway

    OpenAIRE

    Le Parc, Joanna M.; Bischof, Jason J.; King, Andrew M.; Greenberger, Sarah; Way, David P.; Panchal, Ashish R.; Finnegan, Geoffrey I.; Terndrup, Thomas E.

    2018-01-01

    Introduction: Emergency endotracheal intubation (ETI) is a common and critical procedure performed in both prehospital and in-hospital settings. Studies of prehospital providers have demonstrated that rescuer position influences ETI outcomes. However, studies of in-hospital rescuer position for ETI are limited. While we adhere to strict standards for the administration of ETI, we posited that perhaps requiring in-hospital rescuers to stand for ETI is an obstacle to effectiveness. Our objectiv...

  2. The LMACTrach, a Aew Approach for Endotracheal Intubation: Apilot Study in 100 Patients Undergoing Elective Surgery

    OpenAIRE

    Valiollah Hassani; Maryam Zafarghandi; Mohammad Farhadi

    2010-01-01

    Backgroundand endotracheal intubation under direct vision in both anticipated and unexpecteddifficult intubation situations.: The LMA CTrach system is a new device for airway managementMethodsdifferent types of elective surgeries. After randomly selecting the patients for intubationwith this new device, the airway characteristics, height,weight, dental overbiteand thyromental distance were all evaluated before induction.Our goal was to exploreprimarily the success rate of intubation with LMAC...

  3. [Difficult Ventilation Requiring Emergency Endotracheal Intubation during Awake Craniotomy Managed by Laryngeal Mask Airway].

    Science.gov (United States)

    Matsuda, Asako; Mizota, Toshiyuki; Tanaka, Tomoharu; Segawa, Hajime; Fukuda, Kazuhiko

    2016-04-01

    We report a case of difficult ventilation requiring emergency endotracheal intubation during awake craniotomy managed by laryngeal mask airway (LMA). A 45-year-old woman was scheduled to receive awake craniotomy for brain tumor in the frontal lobe. After anesthetic induction, airway was secured using ProSeal LMA and patient was mechanically ventilated in pressure-control mode. Patient's head was fixed with head-pins at anteflex position, and the operation started. About one hour after the start of the operation, tidal volume suddenly decreased. We immediately started manual ventilation, but the airway resistance was extremely high and we could not adequately ventilate the patient. We administered muscle relaxant for suspected laryngospasm, but ventilatory status did not improve; so we decided to conduct emergency endotracheal intubation. We tried to intubate using Airwayscope or LMA-Fastrach, but they were not effective in our case. Finally trachea was intubated using transnasal fiberoptic bronchoscopy. We discuss airway management during awake craniotomy, focusing on emergency endotracheal intubation during surgery.

  4. Effectiveness of the endotracheal tube cuff on the trachea: physical and mechanical aspects

    Directory of Open Access Journals (Sweden)

    Maira Soliani Del Negro

    2014-12-01

    Full Text Available Introduction: The inflation pressure of the endotracheal tube cuff can cause ischemia of the tracheal mucosa at high pressures; thus, it can cause important tracheal morbidity and tracheal microaspiration of the oropharyngeal secretion, or it can even cause pneumonia associated with mechanical ventilation if the pressure of the cuff is insufficient. Objective: In order to investigate the effectiveness of the RUSCH® 7.5 mm endotracheal tube cuff, this study was designed to investigate the physical and mechanical aspects of the cuff in contact with the trachea. Methods: For this end, we developed an in vitro experimental model to assess the flow of dye (methylene blue by the inflated cuff on the wall of the artificial material. We also designed an in vivo study with 12 Large White pigs under endotracheal intubation. We instilled the same dye in the oral cavity of the animals, and we analyzed the presence or not of leakage in the trachea after the region of the cuff after their deaths (animal sacrifice. All cuffs were inflated at the pressure of 30 cmH2O. Results: We observed the passage of fluids through the cuff in all in vitro and in vivo experimental models. Conclusion: We conclude that, as well as several other cuff models in the literature, the RUSCH® 7.5 mm tube cuffs are also not able to completely seal the trachea and thus prevent aspiration of oropharyngeal secretions. Other prevention measures should be taken.

  5. Electrowinning molten titanium from titanium dioxide

    CSIR Research Space (South Africa)

    Van Vuuren, DS

    2005-10-01

    Full Text Available the Manufacturing and Materials Industry in it quest for global competitiveness CSIR Manufacturing and Materials Technology 3 Rationale – Titanium Cost Build-up Material Cost Ilmenite $0.27/kg Ti sponge Titanium slag $0.75/kg Ti Sponge TiCl4 and TiO2 $3....10/kg Ti Sponge Ti Sponge raw materials costs $5.50/kg Ti Sponge Total Ti Sponge cost $9-$11/kg Ti Sponge Ti ingot $15-17/kg Ti Aluminium $1.7/kg Al Supporting the Manufacturing and Materials Industry in its quest for global competitivenessorting...

  6. Laryngeal mask airway versus bag-mask ventilation or endotracheal intubation for neonatal resuscitation.

    Science.gov (United States)

    Qureshi, Mosarrat J; Kumar, Manoj

    2018-03-15

    Providing effective positive pressure ventilation is considered to be the single most important component of successful neonatal resuscitation. Ventilation is frequently initiated manually with bag and face mask (BMV) followed by endotracheal intubation if respiratory depression continues. These techniques may be difficult to perform successfully resulting in prolonged resuscitation or neonatal asphyxia. The laryngeal mask airway (LMA) may achieve initial ventilation and successful resuscitation faster than a bag-mask device or endotracheal intubation. Among newborns requiring positive pressure ventilation for cardio-pulmonary resuscitation, is LMA more effective than BMV or endotracheal intubation for successful resuscitation? When BMV is either insufficient or ineffective, is effective positive pressure ventilation and successful resuscitation achieved faster with the LMA compared to endotracheal intubation? We used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL 2017, Issue 1), MEDLINE via PubMed (1966 to 15 February 2017), Embase (1980 to 15 February 2017), and CINAHL (1982 to 15 February 2017). We also searched clinical trials registers, conference proceedings, and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials. We included randomised and quasi-randomised controlled trials that compared LMA for neonatal resuscitation with either BMV or endotracheal intubation and reported on any outcomes related to neonatal resuscitation specified in this review. Two review authors independently evaluated studies for risk of bias assessments, and extracted data using Cochrane Neonatal criteria. Categorical treatment effects were described as relative risks and continuous treatment effects were described as the mean difference, with 95% confidence intervals (95% CI) of estimates. We included seven trials that involved a total of 794 infants. Five

  7. Chitosan patterning on titanium alloys

    OpenAIRE

    Gilabert Chirivella, Eduardo; Pérez Feito, Ricardo; Ribeiro, Clarisse; Ribeiro, Sylvie; Correia, Daniela; González Martin, María Luisa; Manero Planella, José María; Lanceros Méndez, Senentxu; Gallego Ferrer, Gloria; Gómez Ribelles, José Luis

    2017-01-01

    Titanium and its alloys are widely used in medical implants because of their excellent properties. However, bacterial infection is a frequent cause of titanium-based implant failure and also compromises its osseointegration. In this study, we report a new simple method of providing titanium surfaces with antibacterial properties by alternating antibacterial chitosan domains with titanium domains in the micrometric scale. Surface microgrooves were etched on pure titanium disks at i...

  8. Production of titanium tetrachloride

    International Nuclear Information System (INIS)

    Perillo, P.M.; Botbol, O.

    1990-01-01

    This report presents a summary of results from theoperation of a laboratory scale for the production in batches of approximately 100 gs of titanium tetrachloride by chlorination with chloroform and carbon tetrachloride between 340 deg C and 540 deg C. Chlorination agent vapors were passed through a quartz column reacting with titanium oxide powder agglomerated in little spheres. Obtained titanium tetrachloride was condensed in a condenser, taken in a ballon and then purified by fractional distillation. Optimun temperature for chloroform was 400 deg C with 74 % yield and for carbon tetrachloride was 500 deg C with 69 % yield. (Author) [es

  9. Electroplating on titanium alloy

    Science.gov (United States)

    Lowery, J. R.

    1971-01-01

    Activation process forms adherent electrodeposits of copper, nickel, and chromium on titanium alloy. Good adhesion of electroplated deposits is obtained by using acetic-hydrofluoric acid anodic activation process.

  10. Microscopic observations of osteoblast growth on micro-arc oxidized β titanium

    Science.gov (United States)

    Chen, Hsien-Te; Chung, Chi-Jen; Yang, Tsai-Ching; Tang, Chin-Hsin; He, Ju-Liang

    2013-02-01

    Titanium alloys are widely used in orthopedic and dental implants, owing to their excellent physical properties and biocompatibility. By using the micro-arc oxidation (MAO), we generated anatase-rich (A-TiO2) and rutile-rich (R-TiO2) titanium dioxide coatings, individually on β-Ti alloy, in which the latter achieved an enhanced in vitro and in vivo performance. Thoroughly elucidating how the osteoblasts interact with TiO2 coatings is of worthwhile interest. This study adopts the focused ion beam (FIB) to section off the TiO2 coated samples for further scanning electron microscope (SEM) and transmission electron microscope (TEM) observation. The detailed crystal structures of the TiO2 coated specimens are also characterized. Experimental results indicate osteoblasts adhered more tenaciously and grew conformably with more lamellipodia extent on the R-TiO2 specimen than on the A-TiO2 and raw β-Ti specimens. FIB/SEM cross-sectional images of the cell/TiO2 interface revealed micro gaps between the cell membrane and contact surface of A-TiO2 specimen, while it was not found on the R-TiO2 specimen. Additionally, the number of adhered and proliferated cells on the R-TiO2 specimen was visually greater than the others. Closely examining EDS line scans and elemental mappings of the FIB/TEM cross-sectional images of the cell/TiO2 interface reveals both the cell body and interior space of the TiO2 coating contain nitrogen and sulfur (the biological elements in cell). This finding supports the assumption that osteoblast can grow into the porous structure of TiO2 coatings and demonstrating that the R-TiO2 coating formed by MAO serves the best for β-Ti alloys as orthopedic and dental implants.

  11. Titanium oxide fever

    International Nuclear Information System (INIS)

    De Jonge, D.; Visser, J.

    2012-01-01

    One measure to improve air quality is to apply photo-catalytic substances that capture NOx onto the road surface or onto baffle boards alongside the roads. The effect of titanium oxide containing clinkers with coating was discussed in the report 'Demonstration project of air-purifying pavement in Hengelo, The Netherlands' that was published in May 2011. This article examines the way in which the effectiveness of this study was determined. Can titanium oxide containing clinkers and coatings indeed capture NOx?. [nl

  12. Machining of titanium alloys

    CERN Document Server

    2014-01-01

    This book presents a collection of examples illustrating the resent research advances in the machining of titanium alloys. These materials have excellent strength and fracture toughness as well as low density and good corrosion resistance; however, machinability is still poor due to their low thermal conductivity and high chemical reactivity with cutting tool materials. This book presents solutions to enhance machinability in titanium-based alloys and serves as a useful reference to professionals and researchers in aerospace, automotive and biomedical fields.

  13. A comparison of tape-tying versus a tube-holding device for securing endotracheal tubes in adults.

    Science.gov (United States)

    Murdoch, E; Holdgate, A

    2007-10-01

    During the transfer of intubated patients, endotracheal tube security is paramount. This study aims to compare two methods of securing an endotracheal tube in adults: tying with a cloth tape versus the Thomas Endotracheal Tube Holder (Laerdal). A manikin-based study was performed using paramedics and critical care doctors (consultants and senior trainees) as participants. Each participant was asked to secure an endotracheal tube that had been placed within the trachea of a manikin a total of six times, the first three times using tied cloth tape and the last three times using a Thomas Endotracheal Tube Holder. Following each 'fixation' and after the participant had left the room, the security of the tube was tested by applying a fixed force laterally and to the right by dropping a 1.25 kg weight a distance of 50 cm. The amount of movement of the tube with respect to the teeth was measured and recorded in millimetres. Two-hundred-and-seventy tube fixations (135 tied vs. 135 tube holder) were performed by 45 participants. The degree of tube movement was significantly higher when the tube was secured with a tie compared with when the tube holder was used (median movement 22 mm vs. 4 mm, P tube holder device minimised tube movement in a manikin model when compared with conventional tape tying. The use of this device when transporting intubated patients may reduce the risk of tube displacement though further clinical studies are warranted.

  14. Titanium by design: TRIP titanium alloy

    Science.gov (United States)

    Tran, Jamie

    Motivated by the prospect of lower cost Ti production processes, new directions in Ti alloy design were explored for naval and automotive applications. Building on the experience of the Steel Research Group at Northwestern University, an analogous design process was taken with titanium. As a new project, essential kinetic databases and models were developed for the design process and used to create a prototype design. Diffusion kinetic models were developed to predict the change in phase compositions and microstructure during heat treatment. Combining a mobility database created in this research with a licensed thermodynamic database, ThermoCalc and DICTRA software was used to model kinetic compositional changes in titanium alloys. Experimental diffusion couples were created and compared to DICTRA simulations to refine mobility parameters in the titanium mobility database. The software and database were able to predict homogenization times and the beta→alpha plate thickening kinetics during cooling in the near-alpha Ti5111 alloy. The results of these models were compared to LEAP microanalysis and found to be in reasonable agreement. Powder metallurgy was explored using SPS at GM R&D to reduce the cost of titanium alloys. Fully dense Ti5111 alloys were produced and achieved similar microstructures to wrought Ti5111. High levels of oxygen in these alloys increased the strength while reducing the ductility. Preliminary Ti5111+Y alloys were created, where yttrium additions successfully gettered excess oxygen to create oxides. However, undesirable large oxides formed, indicating more research is needed into the homogeneous distribution of the yttrium powder to create finer oxides. Principles established in steels were used to optimize the beta phase transformation stability for martensite transformation toughening in titanium alloys. The Olson-Cohen kinetic model is calibrated to shear strains in titanium. A frictional work database is established for common alloying

  15. Risk factors for endotracheal intubation and mechanical ventilation in patients with opioids intoxication

    International Nuclear Information System (INIS)

    Mirmoghtadaee, P.; Mood, N.E.; Sabzghabaee, A.M.; Yaraghi, A.

    2012-01-01

    Objectives: Patients poisoned with opioids sometimes need endotracheal intubation with or without the use of mechanical ventilation. This study was done to determine the prognostic risk factors for of the need for endotracheal intubation and mechanical ventilation. Methodology: In this cross-sectional study which was performed in Isfahan (Iran), one hundred (n=100) opioid poisoned patients whom their overdoses were diagnosed by their full and reliable history, physical examination and positive response to naloxone; vital signs at the hospital admission, blood biochemistry, ABG details and also the type and estimated dosage of opioid, route of consumption, and their need to mechanical ventilation were evaluated. Results: Patients were mostly aged between 20-40 years old. Seventy nine patients were male and 26 cases (21 men) required endotracheal intubation and 15 cases (14 men) needed both intubation and mechanical ventilation. The most consumed opiates among the poisoned patients were opium (35%), heroin (16%), Tramadol (15%), Methadone (9%), crack (6%), Diphenoxylate (4%) and others (15%). There was a significant difference between the mean heart rates and respiratory rate of the patients who were connected to the ventilator and others (99.8 +- 21.8 and 87.3 +- 16.3; p=0.01). The lower level of consciousness [OR: 2.2 95% Confidence Interval (CI): 1.2-4.2], and lower admission level of hemoglobin (OR: 3.6; CI:1.2-10.8) were among the factors for predicting the need for intubation and ventilation. Conclusion: Determining the risk factors with prognostic value for the need to intubation or ventilation seems to be necessary for improving the standard of therapy in opioids poisoned patients. (author)

  16. Low-dose esmolol: hemodynamic response to endotracheal intubation in normotensive patients

    Directory of Open Access Journals (Sweden)

    Suresh Lakshmanappa

    2012-06-01

    Full Text Available Abstract Purpose: Endotracheal intubation is a frequently utilized and highly invasive component of anesthesia that is often accompanied by potentially harmful hemodynamic pressor responses. The purpose of this study was to investigate the efficiency of a single pre-induction 1 mg/kg bolus injection of esmolol for attenuating these hemodynamic responses to endotracheal intubation in normotensive patients. Material and methods: The study was composed of 100 randomly selected male and female patients between the ages of 18 and 60 that were scheduled for elective surgery and belonged to ASA grade I or II. Two minutes prior to intubation the control group received 10 mL of saline (n=50 and the experimental group received an injection of esmolol 1 mg/kg diluted to 10 mL (n=50. Heart rate (HR, systolic blood pressure (SBP, diastolic blood pressure (DBP, mean arterial pressure (MAP, and rate pressure product (RPP were compared to basal values before receiving medication (T-0, during pre-induction (T-1, induction (T-2, intubation (T-3, and post-intubation at 1 (T-4, 3 (T-6, 5 (T-8, and 10 (T-13 minutes. Results: Esmolol significantly attenuated the hemodynamic responses to endotracheal intubation at the majority of measured points. Attenuation of HR (10.8%, SBP (7.04%, DBP (3.99%, MAP (5%, and RPP (16.9% was observed in the esmolol group when compared to the control group values. Conclusions: A single pre-induction 1 mg/kg bolus injection of esmolol successfully attenuated the hemodynamic pressor response in normotensive patients. A significant attenuation of heart rate, systolic blood pressure, diastolic blood pressure and mean arterial pressure was observed at the majority of measured time points in the esmolol administered group compared to the control group. [J Contemp Med 2012; 2(2.000: 69-76

  17. Monitoring tidal volumes in preterm infants at birth: mask versus endotracheal ventilation.

    Science.gov (United States)

    van Vonderen, Jeroen J; Hooper, Stuart B; Krabbe, Vera B; Siew, Melissa L; Te Pas, Arjan B

    2015-01-01

    Upper airway distention during mask ventilation could reduce gas volumes entering the lung compared with ventilation via an endotracheal tube. Therefore, respiratory tract volumes were measured in lambs and tidal volumes were compared in preterm infants before and after intubation. In seven preterm lambs, volumes of the airways (oropharynx, trachea, lungs) were assessed. In 10 preterm infants, delta pressures, tidal volumes and leak were measured during ventilation 2 min before (mask ventilation) and 2 min after intubation (endotracheal ventilation). Inflations coinciding with breaths were excluded. Amount of upper airway distention in lambs and differences in inspiratory and expiratory tidal volume before and after intubation. In lambs, the combined trachea and oropharynx contributed to 14 (12-21) % (median (IQR), whereas the oropharynx contributed to 9 (7-10) % of the total tidal volume measured at the mouth. In preterm infants, inspiratory (11.1 (7.9-22.6) mL/kg vs 5.8 (3.9-9.6) mL/kg (p=0.01)) and expiratory (8.3 (6.8-15.4) mL/kg vs 4.9 (3.9-9.6) mL/kg (p=0.02)) tidal volumes were significantly larger during mask ventilation compared with endotracheal ventilation. Leak was 18.7 (3.3-28.7) % before versus 0 (0-2.3) % after intubation (p0.05). During mask ventilation, expiratory tidal volume increased from 10.0 (5.4-15.6) mL/kg to 11.3 (7.6-17.0) mL/kg (p=0.01), but remained unchanged during endotracheal ventilation. During neonatal mask ventilation, distention of the upper respiratory tract contributes to the tidal volumes measured and should be taken into account when targeting tidal volumes during mask ventilation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. MEASUREMENT OF ENDOTRACHEAL TUBE CUFF PRESSURE IN MECHANICALLYVENTILATED PATIENTS ON ARRIVAL TO INTENSIVE CARE UNIT - A CROSS-SECTIONAL STUDY

    Directory of Open Access Journals (Sweden)

    Arun Kumar Ajjappa

    2017-04-01

    Full Text Available BACKGROUND The monitoring of Endotracheal Tube (ETT cuff pressure in intubated patients on arrival to intensive care unit is very essential. The cuff pressure must be within an optimal range of 20-30cm H2O ensuring ventilation with no complications related to cuff overinflation and underinflation. This can be measured with a cuff pressure manometer. The aim of the study is to measure the endotracheal tube cuff pressure in patients on arrival to intensive care unit and to identify prevalence of endotracheal cuff underinflation and overinflation. MATERIALS AND METHODS A cross-sectional study was done on mechanically-ventilated patients who were intubated in casualty (emergency department on arrival to intensive care unit in S.S. Institute of Medical Sciences and Research Centre, Davangere. About 50 critically-ill patients intubated with a high volume, low pressure endotracheal tube were included in the study. An analogue manometer was used to measure the endotracheal tube cuff pressure. It was compared with the recommended level. The settings of mechanical ventilation, endotracheal tube size and peak airway pressure were recorded. RESULTS It was found that the mean cuff pressure was 64.10 cm of H2O with a standard deviation of 32.049. Of the measured cuff pressures, only 2% had pressures within an optimal range (20-30cm of H2O. 88% had cuff pressures more than 30cm of H2O. The mean peak airway pressure found to be 20.50cm of H2O with a Standard Deviation (SD of 5.064. CONCLUSION This study is done to emphasise the importance of cuff pressure measurement in all mechanically-ventilated patients as cuff pressure is found to be high in most of the patients admitted to intensive care unit. Complications of overinflation and underinflation can only be prevented if the acceptable cuff pressures are achieved.

  19. Endotracheal Intubation Using the Macintosh Laryngoscope or KingVision Video Laryngoscope during Uninterrupted Chest Compression

    Directory of Open Access Journals (Sweden)

    Ewelina Gaszynska

    2014-01-01

    Full Text Available Objective. Advanced airway management, endotracheal intubation (ETI, during CPR is more difficult than, for example, during anesthesia. However, new devices such as video laryngoscopes should help in such circumstances. The aim of this study was to assess the performance of the KingVision video laryngoscopes in a manikin cardiopulmonary resuscitation (CPR scenario. Methods. Thirty students enrolled in the third year of paramedic school took part in the study. The simulated CPR scenario was ETI using the standard laryngoscope with a Macintosh blade (MCL and ETI using the KingVision video laryngoscope performed during uninterrupted chest compressions. The primary endpoints were the time needed for ETI and the success ratio. Results. The mean time required for intubation was similar for both laryngoscopes: 16.6 (SD 5.11, median 15.64, range 7.9–27.9 seconds versus 17.91 (SD 5.6, median 16.28, range 10.6–28.6 seconds for the MCL and KingVision, respectively (P=0.1888. On the first attempt at ETI, the success rate during CPR was comparable between the evaluated laryngoscopes: P=0.9032. Conclusion. The KingVision video laryngoscope proves to be less superior when used for endotracheal intubation during CPR compared to the standard laryngoscope with a Mackintosh blade. This proves true in terms of shortening the time needed for ETI and increasing the success ratio.

  20. Comparison of armoured laryngeal mask airway with endotracheal tube for adenotonsillectomy

    International Nuclear Information System (INIS)

    Aziz, L.; Bashir, K.

    2006-01-01

    To assess the reliability of armoured laryngeal mask airway for adenotonsillectomy and to compare the haemodynamic changes during anaesthesia with those of endotracheal tube. A total of 100 patients undergoing adenotonsillectomy between ages 10-35 years and ASA I status were enrolled for the study. Two groups with 50 patients in each group were formed. Group I patients underwent surgery with armoured laryngeal mask airway while group II underwent surgery with endotracheal intubation. Baseline heart rate, systolic blood pressure and diastolic blood pressure were noted pre-operatively, one minute after insertion and every five minutes after induction in both the groups. A change in all these haemodynamic parameters from the baseline was noted. The effect of Boyle Davis Gag and adequacy of surgical access were also noted. Occurrence of cough, laryngospasm and stridor were noted at the time of recovery in both the groups. Baseline variables in both groups were identical. Surgical access was adequate in 48/50 patients in group I while it was adequate in 49/50 patients in group II. The frequencies of cough, laryngeal spasm and stridor were lower in group I. In group I, there was insignificant change from baseline in heart rate, systolic and diastolic blood pressure at one, five and ten minutes after induction. In group II, significant change from baseline was observed in heart rate (p <0.01), systolic blood pressure (p <0.05) and diastolic blood pressure (p <0.05). (author)

  1. The effects of succinylcholine or low-dose rocuronium to aid endotracheal intubation of adult sows

    Science.gov (United States)

    Duke-Novakovski, Tanya; Ambros, Barbara; Auckland, Crissie D.; Harding, John C.S.

    2012-01-01

    This randomized, prospective, blinded study compared the use of succinylcholine or rocuronium to aid endotracheal intubation of 27 adult sows [mean body weight 261 ± 28 (standard deviation) kg]. Preliminary trials allowed development of the intubation technique and skills. The sows were premedicated with azaperone, atropine, and morphine, and anesthesia was induced with thiopental [6 mg/kg body weight (BW)]. Nine sows each received succinylcholine (1.0 mg/kg BW), rocuronium (0.5 mg/kg BW), or saline (15 mL) after induction. Increments of thiopental (1 mg/kg BW) were used if swallowing impaired intubation. Intubation was performed 45 s after injection of the test drug and was timed and scored. The intubation scores were analyzed with Kruskal-Wallis analysis of variance (ANOVA). Time taken for intubation, body weight, and total dose of thiopental were analyzed with ANOVA and Bonferroni’s multiple-comparisons test. No significant differences (at P < 0.05) were found between the groups with regard to intubation score, time taken for intubation, or total thiopental dose. Thus, neuromuscular blocking agents did not aid endotracheal intubation of adult sows anesthetized with thiopental. PMID:22754096

  2. Intraoperative Atelectasis Due to Endotracheal Tube Cuff Herniation: A Case Report

    Directory of Open Access Journals (Sweden)

    Hossein Madineh

    2012-09-01

    Full Text Available Endotracheal tube (ETT cuff herniation is a rare, and often difficult to diagnose, cause of bronchial obstruction. We present a case of outside cuff herniation of an endotracheal tube that caused pulmonary right lung atelectasis. A 29-year-old man ,a case of car accident with multiple fractures, was admitted to the emergency ward and transferred to the operating room(OR for open reduction and internal fixation (ORIF of all fractures .The procedures were done under general anesthesia (G/A. The past medical history of the patient did not indicate any problem. Anesthesia was induced with thiopental, atracurium and then maintained by propofol and remifentanyl infusions and 100% O2 via orally inserted ETT. The patient was positioned in left lateral decubitus position for operation. Two hours after induction of anesthesia, the oxygen saturation level dropped to 85 % and the breath sounds in the right side of the chest were weakened. The chest x-ray images showed right lung atelectasis especially in the upper lobe. The problem was disappeared after removal of the ETT. In this case, we observed that an ETT cuff herniation can be a cause of airway obstruction. If there is a decreased unilateral breath sounds, we recommend replacement or repositioning of ETT.

  3. Titanium metal: extraction to application

    Energy Technology Data Exchange (ETDEWEB)

    Gambogi, Joseph (USGS, Reston, VA); Gerdemann, Stephen J.

    2002-09-01

    In 1998, approximately 57,000 tons of titanium metal was consumed in the form of mill products (1). Only about 5% of the 4 million tons of titanium minerals consumed each year is used to produce titanium metal, with the remainder primarily used to produce titanium dioxide pigment. Titanium metal production is primarily based on the direct chlorination of rutile to produce titanium tetrachloride, which is then reduced to metal using the Kroll magnesium reduction process. The use of titanium is tied to its high strength-to-weight ratio and corrosion resistance. Aerospace is the largest application for titanium. In this paper, we discuss all aspects of the titanium industry from ore deposits through extraction to present and future applications. The methods of both primary (mining of ore, extraction, and purification) and secondary (forming and machining) operations will be analyzed. The chemical and physical properties of titanium metal will be briefly examined. Present and future applications for titanium will be discussed. Finally, the economics of titanium metal production also are analyzed as well as the advantages and disadvantages of various alternative extraction methods.

  4. Industrial experience with titanium

    International Nuclear Information System (INIS)

    Ikeda, B.M.; Shoesmith, D.W.

    1997-09-01

    Titanium is a reference material for the construction of waste containers in the Canadian Nuclear Fuel Waste Management Program. It has been in industrial service for over 30 a, often in severe corrosion environments, but it is still considered a relatively exotic material with limited operating history. This has arisen because of the aerospace applications of this material and the misconception that the high strength-to-weight ratio dominates the choice of this material. In fact, the advantage of titanium lies in its high reliability and excellent corrosion resistance. It has a proven record in seawater heat exchanger service and a demonstrated excellent reliability even in polluted water. For many reasons it is the technically correct choice of material for marine applications. In this report we review the industrial service history of titanium, particularly in hot saline environments, and demonstrate that it is a viable waste container material, based upon this industrial service history and operating experience. (author)

  5. Surface modification of titanium and titanium alloys by ion implantation.

    Science.gov (United States)

    Rautray, Tapash R; Narayanan, R; Kwon, Tae-Yub; Kim, Kyo-Han

    2010-05-01

    Titanium and titanium alloys are widely used in biomedical devices and components, especially as hard tissue replacements as well as in cardiac and cardiovascular applications, because of their desirable properties, such as relatively low modulus, good fatigue strength, formability, machinability, corrosion resistance, and biocompatibility. However, titanium and its alloys cannot meet all of the clinical requirements. Therefore, to improve the biological, chemical, and mechanical properties, surface modification is often performed. In view of this, the current review casts new light on surface modification of titanium and titanium alloys by ion beam implantation. (c) 2010 Wiley Periodicals, Inc.

  6. Thermogravimetric experiments with titanium

    International Nuclear Information System (INIS)

    Porter, L.J.; Longhurst, G.R.

    1991-02-01

    In the process of preparing for pyrophoricity experiments involving uranium, we conducted hydriding and air-exposure experiments on titanium. In these experiments the hydriding reactions and response to air-exposure was generally within the range expected based on work reported by others. One aberrant behavior was a sudden weight gain followed by a significant weight loss. We speculate that loss may be due to hydrogen evolution from the TiH 2 resulting from local heating by oxidation reactions. We verified that titanium is not pyrophoric at temperatures less than 750 degree C. 18 refs. 1 fig

  7. Endotracheal intubation

    Science.gov (United States)

    ... the esophagus or stomach. Risks include: Bleeding Infection Trauma to the voice box (larynx), thyroid gland, vocal cords and windpipe (trachea), or esophagus Puncture or tearing (perforation) of body parts in the chest cavity, leading to lung collapse

  8. HEAT AND MOISTURE EXCHANGE CAPACITY OF THE UPPER RESPIRATORY TRACT AND THE EFFECT OF TRACHEOTOMY BREATHING ON ENDOTRACHEAL CLIMATE

    NARCIS (Netherlands)

    Scheenstra, Renske J.; Muller, Sara H.; Vincent, Andrew; Hilgers, Frans J. M.

    2011-01-01

    Background. The aim of this study was to assess the heat and moisture exchange (HME) capacity of the upper respiratory tract and the effect of tracheotomy breathing on endotracheal climate in patients with head and neck cancer. Methods. We plotted the subglottic temperature and humidity measurements

  9. Comparison of rocuronium at two different doses and succinylcholine for endotracheal intubation in adult patients for elective surgeries

    Directory of Open Access Journals (Sweden)

    S G Chavan

    2016-01-01

    Conclusion: Rapid sequence induction of anesthesia with propofol and fentanyl, succinylcholine allowed a more rapid endotracheal intubation sequence and created superior intubation conditions than rocuronium. However, the technique of using a large dose of rocuronium to achieve perfect conditions for tracheal intubation may have application whenever succinylcholine is relatively contraindicated.

  10. Heat and moisture exchange capacity of the upper respiratory tract and the effect of tracheotomy breathing on endotracheal climate

    NARCIS (Netherlands)

    Scheenstra, R.J.; Muller, S.H.; Vincent, A.; Hilgers, F.J.M.

    2011-01-01

    Background. The aim of this study was to assess the heat and moisture exchange (HME) capacity of the upper respiratory tract and the effect of tracheotomy breathing on endotracheal climate in patients with head and neck cancer. Methods. We plotted the subglottic temperature and humidity measurements

  11. Titanium and zirconium alloys

    International Nuclear Information System (INIS)

    Pinard Legry, G.

    1994-01-01

    Titanium and zirconium pure and base alloys are protected by an oxide film with anionic vacancies which gives a very good resistance to corrosion in oxidizing medium, in some ph ranges. Results of pitting and crevice corrosion are given for Cl - , Br - , I - ions concentration with temperature and ph dependence, also with oxygenated ions effect. (A.B.). 32 refs., 6 figs., 3 tabs

  12. Endotracheal tube cuff pressures during general anaesthesia while using air versus a 50% mixture of nitrous oxide and oxygen as inflating agents

    Directory of Open Access Journals (Sweden)

    Jesni Joseph Manissery

    2007-01-01

    Full Text Available The present study was aimed at assessing the efficacy of filling a 50% mixture of nitrous oxide : oxygen (50%N 2 O:O 2 in the endotracheal tube cuff to provide stable cuff pressures during general anaesthesia with 67%N 2 O. The endotracheal tube cuff pressures with air (control as the inflating agent in the tubes were found to have a total mean pressure of 62.60±12.33 at the end of one hour of general anaesthesia. When comparing the endotracheal tube cuff pressures in the Mallinckrodt tubes with that of the Portex tubes, with air as the inflating agent, the Portex tubes showed a significantly lower cuff pressures at the end of one hour. The endotracheal tube cuff pressures with 50%N 2 O:O 2 as the inflating agent showed a total mean pressure of 27.63 ± 3.221 at the end of one hour of general anaesthesia. This indicates that inflation of the cuff of the endotracheal tubes with a 50%N 2 O:O 2 rather than air maintains a stable intra cuff pressure. Therefore, the method of using a 50%N 2 O:O 2 for filling endotracheal tube cuff can be adopted for endotracheal tubes with high-volume, low-pressure cuffs to prevent both excessive cuff pressure and disruption of cuff seal, during general anaesthesia lasting up to one hour.

  13. Comparison of Tidal Volumes at the Endotracheal Tube and at the Ventilator.

    Science.gov (United States)

    Kim, Paul; Salazar, Adler; Ross, Patrick A; Newth, Christopher J L; Khemani, Robinder G

    2015-11-01

    Lung protective ventilation for children with acute respiratory distress syndrome requires accurate assessment of tidal volume. Although modern ventilators compensate for ventilator tubing compliance, tidal volume measured at the ventilator may not be accurate, particularly in small children. Although ventilator-specific proximal flow sensors that measure tidal volume at the endotracheal tube have been developed, there is little information regarding their accuracy. We sought to test the accuracy of ventilator measured tidal volume with and without proximal flow sensors against a calibrated pneumotachometer in children. Prospective, observational. Tertiary care PICU. Fifty-one endotracheally intubated and mechanically ventilated children younger than 18 years. Tidal volumes were measured at the ventilator, using a ventilator-specific flow sensor, and a calibrated pneumotachometer connected to the SensorMedics 2600A Pediatric Pulmonary Function Cart. In a pressure control mode of ventilation: median tidal volume measured with the pneumotachometer (9.5 mL/kg [interquartile range, 8.2-11.7 mL/kg]) was significantly higher than tidal volume measured either at the ventilator (8.2 mL/kg [7.1-9.6 mL/kg]) or at the proximal flow sensor (8.1 mL/kg [7.2-10.0 mL/kg]) (p tidal volume measured with the pneumotachometer (10.2 mL/kg [8.8-12.4 mL/kg]) was significantly higher than tidal volume measured either at the ventilator (8.0 mL/kg [7.1-9.7 mL/kg]) or at the proximal flow sensor (8.5 mL/kg [7.3-10.4 mL/kg]) (p Tidal volume measured either at the endotracheal tube with a proximal flow sensor or at the ventilator with compensation for tubing compliance are both significantly lower than tidal volume measured with a calibrated pneumotachometer. This underestimation of delivered tidal volume may be particularly important when managing children with acute respiratory distress syndrome.

  14. Lightwand-Guided Endotracheal Intubation Performed by the Nondominant Hand is Feasible

    Directory of Open Access Journals (Sweden)

    Yi-Wei Kuo

    2007-10-01

    Full Text Available The aim of this study was to evaluate the efficiency of lightwand-guided endotracheal intubation (LWEI performed using either the right (dominant or left (nondominant hand. Two hundred and forty patients aged 21–64 years, with a Mallampati airway classification grade of I—II and undergoing endotracheal intubation under general anesthesia, were enrolled in this randomized and controlled study. Induction of anesthesia was initiated by intravenous administration of fentanyl (2 mg/kg and thiopentone (5mg/kg, and tracheal intubation was facilitated by intravenous atracurium (0.5 mg/kg. In the direct-vision laryngoscope group (group D; n = 80, the intubator held the laryngoscope in the left hand and inserted the endotracheal tube (ETT into the glottic opening with the right hand. In the group in which LWEI was performed with the right hand (group R; n = 80, the intubator lifted the patients' jaws with the left hand and inserted the ETT-LW unit into the glottic openings with the right hand. On the contrary, in the group in which LWEI was performed with the left hand (group L; n = 80, the intubator lifted the jaws with the right hand and inserted the ETT-LW unit with the left hand. Data including total intubation time, the number of intubation attempts, hemodynamic changes during intubation, and side effects following intubation, were collected. Regardless of whether lightwand manipulation was performed with the left hand (group L; 11.4 ± 9.3 s or the right-hand (group R; 12.4 ± 9.2 s, less time was consumed in the LWEI groups than in the laryngoscope group (group D; 17.9 ± 9.9s (p 95% on their first intubation attempts. The changes in mean arterial blood pressure and heart rate were similar among the three groups. A higher incidence of intubation-related oral injury and ventricular premature contractions (VPC was found in group D compared with groups L and R (oral injury: group D 8.5%, group L 1.3%, group R 0%, p = 0.005; VPC: group D 16

  15. A Note regarding Problems with Interaction and Varying Block Sizes in a Comparison of Endotracheal Tubes

    Directory of Open Access Journals (Sweden)

    Richard L. Einsporn

    2014-01-01

    Full Text Available A randomized clinical experiment to compare two types of endotracheal tubes utilized a block design where each of the six participating anesthesiologists performed tube insertions for an equal number of patients for each type of tube. Five anesthesiologists intubated at least three patients with each tube type, but one anesthesiologist intubated only one patient per tube type. Overall, one type of tube outperformed the other on all three effectiveness measures. However, analysis of the data using an interaction model gave conflicting and misleading results, making the tube with the better performance appear to perform worse. This surprising result was caused by the undue influence of the data for the anesthesiologist who intubated only two patients. We therefore urge caution in interpreting results from interaction models with designs containing small blocks.

  16. Catheter and Laryngeal Mask Endotracheal Surfactant Therapy: the CALMEST approach as a novel MIST technique.

    Science.gov (United States)

    Vannozzi, Ilaria; Ciantelli, Massimiliano; Moscuzza, Francesca; Scaramuzzo, Rosa T; Panizza, Davide; Sigali, Emilio; Boldrini, Antonio; Cuttano, Armando

    2017-10-01

    Neonatal respiratory distress syndrome (RDS) is a major cause of mortality and morbidity among preterm infants. Although the INSURE (INtubation, SURfactant administration, Estubation) technique for surfactant replacement therapy is so far the gold standard method, over the last years new approaches have been studied, i.e. less invasive surfactant administration (LISA) or minimally invasive surfactant therapy (MIST). Here we propose an originally modified MIST, called CALMEST (Catheter And Laryngeal Mask Endotracheal Surfactant Therapy), using a particular laryngeal mask as a guide for a thin catheter to deliver surfactant directly in the trachea. We performed a preliminary study on a mannequin and a subsequent in vivo pilot trial. This novel procedure is quick, effective and well tolerated and might represent an improvement in reducing neonatal stress. Ultimately, CALMEST offers an alternative approach that could be extremely useful for medical staff with low expertise in laryngoscopy and intubation.

  17. Normative Values and Interrelationship of MDVP Voice Analysis Parameters Before and After Endotracheal Intubation

    DEFF Research Database (Denmark)

    Sørensen, Martin Kryspin; Durck, Tina Trier; Bork, Kristian

    2016-01-01

    normative values for adults and investigates the correlation between these MDVP parameters in relation to the "standardized" trauma of endotracheal intubation. METHODS: Preoperative and postoperative assessments of vocal fold pathology with flexible videolaryngoscopy and voice analysis with MDVP using...... the best-of-three standardized recording were performed in 121 patients with normal voices included consecutively in the RCT. The procedures of anesthesia were standardized. RESULTS: The normative MDVP values of this study are consistently lower compared with most normative values presented in other...... studies. The preoperative to postoperative differences in jitter values (jitter and relative average perturbation) were closely correlated to the shimmer values for patients with postoperative vocal fold edemas. In the patients with edema, the preoperative to postoperative differences in jitter had...

  18. Easy method of centralized fixation of endotracheal tube in cleft lip and palate surgery

    Directory of Open Access Journals (Sweden)

    S P Bajaj

    2012-01-01

    Full Text Available As we all know that fixation of endotracheal tube is very important aspect in cleft palate and maxillofacial surgery. During cleft palate and oral surgery various methods of fixation and modified tubes are deviced to make surgery safer and ergonomically better. Our method consist of 3 point fixation of tube (RAE with dynaplast, which is freely available, cheap and good Adhesive quality. Dynaplast divided into 3 phalanges (one central and two lateral and one portion undivided as central limb. This undivided central limb is fixed in centre of chin and other 3 phalanges wrap around tube on either side. This fixation totally takes away any lateral movements of tube. This method can be used with any tube (RAE/ Oxford/Flexometallic. Our method is described for its simplicity, ease and convinence and result which impart universally similar results with all different members of our anesthetist team.

  19. Endotracheal tube placement by EMT-Basics in a rural EMS system.

    Science.gov (United States)

    Pratt, Jeffrey C; Hirshberg, Alan J

    2005-01-01

    To evaluate the effectiveness of an intubation-training module and special-waiver project in which Emergency Medical Technician (EMT)-Basics were trained to perform endotracheal intubations in a rural community. This was a prospective observational study over a four-year period (July 1998 through May 2002) of all intubation attempts by EMT-Basics in the field. The authors observed intubation data, training methods, and quality-assurance methods of a special-waiver project agreed to by the State Department of Public Health to train and allow EMT-Basics to intubate patients. Data were from documentation unique to the project. Project documentation evaluated the placement and complication(s) of endotracheal tube (ETT) placement after arrival to the emergency department. An intubation attempt was defined as direct laryngoscopy. A successful attempt was defined as an appropriately sized ETT placed and secured in the trachea below the vocal cords and above the carina. Confirmation of placement in the field included accepted clinical methods and the use of qualitative colorimetric end-tidal carbon dioxide detectors. The EMT-Basics were trained using a paramedic curriculum, including operating room intubations on live adult patients. All patients were in either cardiopulmonary or respiratory arrest. Thirty-two intubations were performed by EMT-Basics. Thirty attempts were successful and two were unsuccessful (94%; 95% confidence interval [CI] 80-98%). Unsuccessful ETT placements were managed with accepted basic life support airway standards. There were no unrecognized esophageal ETT placements (0%; 95% CI 0-11%). This study demonstrated that with an intensive training program using selected highly motivated providers and close monitoring, a program of EMT-Basic ETT placement in a rural setting can achieve acceptable success rates in patients in cardiac or respiratory arrest.

  20. Corrosion casting of the subglottis following endotracheal tube intubation injury: a pilot study in Yorkshire piglets

    Science.gov (United States)

    2013-01-01

    Purpose Subglottic stenosis can result from endotracheal tube injury. The mechanism by which this occurs, however, is not well understood. The purpose of this study was to examine the role of angiogenesis, hypoxia and ischemia in subglottic mucosal injury following endotracheal intubation. Methods Six Yorkshire piglets were randomized to either a control group (N=3, ventilated through laryngeal mask airway for corrosion casting) or accelerated subglottic injury group through intubation and induced hypoxia as per a previously described model (N=3). The vasculature of all animals was injected with liquid methyl methacrylate. After polymerization, the surrounding tissue was corroded with potassium hydroxide. The subglottic region was evaluated using scanning electron microscopy looking for angiogenic and hypoxic or degenerative features and groups were compared using Mann–Whitney tests and Friedman’s 2-way ANOVA. Results Animals in the accelerated subglottic injury group had less overall angiogenic features (P=.002) and more overall hypoxic/degenerative features (P=.000) compared with controls. Amongst angiogenic features, there was decreased budding (P=.000) and a trend toward decreased sprouting (P=.037) in the accelerated subglottic injury group with an increase in intussusception (P=.004), possibly representing early attempts at rapid revascularization. Amongst hypoxic/degenerative features, extravasation was the only feature that was significantly higher in the accelerated subglottic injury group (P=.000). Conclusions Subglottic injury due to intubation and hypoxia may lead to decreased angiogenesis and increased blood vessel damage resulting in extravasation of fluid and a decreased propensity toward wound healing in this animal model. PMID:24401165

  1. Reliability of Ultrasonography in Confirming Endotracheal Tube Placement in an Emergency Setting

    Science.gov (United States)

    Thomas, Vimal Koshy; Paul, Cherish; Rajeev, Punchalil Chathappan; Palatty, Babu Urumese

    2017-01-01

    Background and Objectives: Over the past few years, ultrasonography is increasingly being used to confirm the correct placement of endotracheal tube (ETT). In our study, we aimed to compare it with the traditional clinical methods and the gold standard quantitative waveform capnography. Two primary outcomes were measured in our study. First was the sensitivity and specificity of ultrasonography against the other two methods to confirm endotracheal intubation. The second primary outcome assessed was the time taken for each method to confirm tube placement in an emergency setting. Methods: This is a single-centered, prospective cohort study conducted in an emergency department of a tertiary care hospital. We included 100 patients with indication of emergency intubation by convenient sampling. The intubation was performed as per standard hospital protocol. As part of the study protocol, ultrasonography was used to identify ETT placement simultaneously with the intubation procedure along with quantitative waveform capnography (end-tidal carbon dioxide) and clinical methods. Confirmation of tube placement and time taken for the same were noted by three separate health-care staffs. Results and Discussion: Out of the 100 intubation attempts, five (5%) had esophageal intubations. The sensitivity and specificity of diagnosis using ultrasonography were 97.89% and 100%, respectively. This was statistically comparable with the other two modalities. The time taken to confirm tube placement with ultrasonography was 8.27 ± 1.54 s compared to waveform capnography and clinical methods which were 18.06 ± 2.58 and 20.72 ± 3.21 s, respectively. The time taken by ultrasonography was significantly less. Conclusions: Ultrasonography confirmed tube placement with comparable sensitivity and specificity to quantitative waveform capnography and clinical methods. But then, it yielded results considerably faster than the other two modalities. PMID:28584427

  2. "COMPARISON OF HEMODYNAMIC CHANGES AFTER INSERTION OF LARYNGEAL MASK AIRWAY, FACEMASK AND ENDOTRACHEAL INTUBATION"

    Directory of Open Access Journals (Sweden)

    K. Montazari

    2004-11-01

    Full Text Available Hemodynamic changes are major hazards of general anesthesia and are probably generated by direct laryngoscopy and endotracheal intubation. We designed this prospective randomised study to assess the cardiovascular changes after either laryngeal mask airway (LMA, face mask (FM or endotracheal tube (ETT insertion in the airway management of adult patients anesthetised with nitrous oxide and halothane. A total of 195 healthy normotensive adult patients with normal airways were randomly assigned to one of the three groups according to their airway management (n= 65 each for transurethral lithotripsy procedures. Heart rate (HR, systolic blood pressure (SBP, diastolic blood pressure (DBP and mean arterial blood pressure (MAP values were recorded before the induction of anesthesia, and then every three minutes until 30 min thereafter. The mean maximum HR and MAP values obtained during 15 and 30 minutes after insertion of LMA were 81±13, 73±8 bpm and 82±14, 79 ±11 mmHg, respectively which were significantly smaller compared to those with FM (84±12, 80±6 bpm and 86±10, 83±13 mmHg and ETT (96±8, 88±7 bpm and 91±11, 82±9 mmHg (P< 0.05. Direct stimulation of the trachea appears to be a major cause of the hemodynamic changes associated with tracheal intubation during general anesthesia, but why hemodynamic changes in LMA were smaller than facemask needs further study. In healthy normotensive patients the use of LMA for the airway management during general anesthesia results in a smaller cardiovascular change than FM and ETT.

  3. Isolation of Separate Ureaplasma Species From Endotracheal Secretions of Twin Patients.

    Science.gov (United States)

    Beeton, Michael L; Maxwell, Nicola C; Chalker, Victoria J; Brown, Rebecca J; Aboklaish, Ali F; Spiller, O Brad

    2016-08-01

    Isolation of Ureaplasma spp. from preterm neonates and the association with development of bronchopulmonary dysplasia has been previously investigated. However, few studies have contrasted the nature of infection in twins. In this article, we report that dizygotic twins (1 girl, 1 boy) born at 24 weeks gestation both yielded culturable Ureaplasma from endotracheal secretions. The samples were part of a serial blind collection cohort of ventilated premature neonates, and analysis of repeat cultures showed stable, separate infections over a period of 17 and 21 days, respectively. Immunoblot and probe-specific quantitative polymerase chain reaction analysis determined that Twin 1 was solely infected with Ureaplasma parvum (specifically, serovar 6 by gene sequencing), whereas Twin 2 was solely infected with Ureaplasma urealyticum (specifically, genotype A- serovars 2, 5, and 8 by gene sequencing). Immunoblot analysis found that the major surface antigen (multiple-banded antigen) altered relative mass for both strains during the course of infection. Quantitative polymerase chain reaction analysis of extracted endotracheal aspirates confirmed no evidence of mixed infection for either twin. Failure of sentinel ventilated preterm infants on the same ward to acquire Ureaplasma infection after the first week of birth suggests no cot-to-cot transfer of Ureaplasma infection occurred. This study demonstrated not only a contrasting clinical outcome for a set of twins infected with 2 separate species of Ureaplasma, but also the first real-time demonstration of multiple-banded antigen alteration and evolution of Ureaplasma over the course of a clinical infection. Copyright © 2016 by the American Academy of Pediatrics.

  4. Epistaxis during nasotracheal intubation: a randomized trial of the Parker Flex-Tip™ nasal endotracheal tube with a posterior facing bevel versus a standard nasal RAE endotracheal tube.

    Science.gov (United States)

    Earle, Rosie; Shanahan, Enda; Vaghadia, Himat; Sawka, Andrew; Tang, Raymond

    2017-04-01

    Nasotracheal intubation is a widely performed technique to facilitate anesthesia induction during oral, dental, and maxillofacial surgeries. The technique poses several risks not encountered with oropharyngeal intubation, most commonly epistaxis due to nasal mucosal abrasion. The purpose of this study was to test whether the use of the Parker Flex-Tip™ (PFT) nasal endotracheal tube (ETT) with a posterior facing bevel reduces epistaxis when compared with the standard nasal RAE ETT with a leftward facing bevel. Sixty American Society of Anesthesiologists physical status I and II patients undergoing oral or maxillofacial surgery with nasotracheal intubation were recruited. Patients were randomized to either a standard nasal RAE ETT or a PFT nasal ETT. The ETT was thermosoftened and lubricated for both study groups prior to insertion, and the size of the tube was chosen at the discretion of the attending anesthesiologist. The primary outcome was the incidence of epistaxis, with a secondary outcome of epistaxis severity (scored as none, mild, moderate, or severe). An investigator measured both outcomes five minutes after intubation was completed. Mild or moderate epistaxis was experienced by 22 of 30 (73%) patients in the PFT group compared with 21 of 30 (70%) patients in the standard nasal RAE ETT group (absolute risk reduction, 3%; 95% confidence interval, -19 to 25; P = 0.78). There were no occurrences of severe epistaxis in either group. There was no difference in the incidence or severity of epistaxis following nasal intubation using the Parker Flex-Tip nasal ETT when compared with a standard nasal RAE ETT. This trial was registered at ClinicalTrials.gov, identifier: NCT02315677.

  5. A comparison of a traditional endotracheal tube versus ETView SL in endotracheal intubation during different emergency conditions: A randomized, crossover cadaver trial.

    Science.gov (United States)

    Truszewski, Zenon; Krajewski, Paweł; Fudalej, Marcin; Smereka, Jacek; Frass, Michael; Robak, Oliver; Nguyen, Bianka; Ruetzler, Kurt; Szarpak, Lukasz

    2016-11-01

    Airway management is a crucial skill essential to paramedics and personnel working in Emergency Medical Services and Emergency Departments: Lack of practice, a difficult airway, or a trauma situation may limit the ability of paramedics to perform direct laryngoscopy during cardiopulmonary resuscitation. Videoscope devices are alternatives for airway management in these situations. The ETView VivaSight SL (ETView; ETView Ltd., Misgav, Israel) is a new, single-lumen airway tube with an integrated high-resolution imaging camera. To assess if the ETView VivaSight SL can be a superior alternative to a standard endotracheal tube for intubation in an adult cadaver model, both during and without simulated CPR. ETView VivaSight SL tube was investigated via an interventional, randomized, crossover, cadaver study. A total of 52 paramedics participated in the intubation of human cadavers in three different scenarios: a normal airway at rest without concomitant chest compression (CC) (scenario A), a normal airway with uninterrupted CC (scenario B) and manual in-line stabilization (scenario C). Time and rate of success for intubation, the glottic view scale, and ease-of-use of ETView vs. sETT intubation were assessed for each emergency scenario. The median time to intubation using ETView vs. sETT was compared for each of the aforementioned scenarios. For scenario A, time to first ventilation was achieved fastest for ETView, 19.5 [IQR, 16.5-22] sec, when compared to that of sETT at 21.5 [IQR, 20-25] sec (p = .013). In scenario B, the time for intubation using ETView was 21 [IQR, 18.5-24.5] sec (p cadavers and the time to ventilation were improved with the ETView. The time to glottis view, tube insertion, and cuff block were all found to be shorter with the ETView. clinicaltrials.gov Identifier: NCT02733536.

  6. Mechanochemistry of titanium oxides

    Directory of Open Access Journals (Sweden)

    Veljković Ivana

    2009-01-01

    Full Text Available Mechanochemistry represents an alternative route in synthesis of nanomaterials. Mechanochemical routes are attractive because of their simplicity, flexibility, and ability to prepare materials by solid state reactions at room temperature. The aim of this work is the mechanochemical synthesis of nanostructured titanium oxides of different composition starting from mixtures of Ti and TiO2, TiO and TiO2 or Ti2O3 and TiO2. Emphasis is on the Magneli phases Ti4O7 and Ti5O9 because their mixture is commercially known as EBONEX material. The materials prepared were characterized by XRPD, TG/DTA analysis, SEM and optical microscopy. Titanium monoxide and several Magneli oxides, Ti4O7, Ti5O9 and Ti6O11, are successfully prepared. The results are very interesting because the EBONEX materials were prepared at lower than usual temperature, which would decrease the effective cost of production.

  7. Industrial experience with titanium

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, B M; Shoesmith, D W

    1997-09-01

    Titanium is a reference material for the construction of waste containers in the Canadian Nuclear Fuel Waste Management Program. It has been in industrial service for over 30 a, often in severe corrosion environments, but it is still considered a relatively exotic material with limited operating history. This has arisen because of the aerospace applications of this material and the misconception that the high strength-to-weight ratio dominates the choice of this material. In fact, the advantage of titanium lies in its high reliability and excellent corrosion resistance. It has a proven record in seawater heat exchanger service and a demonstrated excellent reliability even in polluted water. For many reasons it is the technically correct choice of material for marine applications. In this report we review the industrial service history of titanium, particularly in hot saline environments, and demonstrate that it is a viable waste container material, based upon this industrial service history and operating experience. (author) 83 refs., 17 tabs., 3 figs.

  8. Advances in titanium alloys

    International Nuclear Information System (INIS)

    Seagle, S.R.; Wood, J.R.

    1993-01-01

    As described above, new developments in the aerospace market are focusing on higher temperature alloys for jet engine components and higher strength/toughness alloys for airframe applications. Conventional alloys for engines have reached their maximum useful temperature of about 1000 F (540 C) because of oxidation resistance requirements. IMI 834 and Ti-1100 advanced alloys show some improvement, however, the major improvement appears to be in gamma titanium aluminides which could extend the maximum usage temperature to about 1500 F (815 C). This puts titanium alloys in a competitive position to replace nickel-base superalloys. Advanced airframe alloys such as Ti-6-22-22S, Beta C TM , Ti-15-333 and Ti-10-2-3 with higher strength than conventional Ti-6-4 are being utilized in significantly greater quantities, both in military and commercial applications. These alloys offer improved strength with little or no sacrifice in toughness and improved formability, in some cases. Advanced industrial alloys are being developed for improved corrosion resistance in more reducing and higher temperature environments such as those encountered in sour gas wells. Efforts are focused on small precious metal additions to optimize corrosion performance for specific applications at a modest increase in cost. As these applications develop, the usage of titanium alloys for industrial markets should steadily increase to approach that for aerospace applications. (orig.)

  9. Titanium fasteners. [for aircraft industry

    Science.gov (United States)

    Phillips, J. L.

    1972-01-01

    Titanium fasteners are used in large quantities throughout the aircraft industry. Most of this usage is in aluminum structure; where titanium structure exists, titanium fasteners are logically used as well. Titanium fasteners offer potential weight savings to the designer at a cost of approximately $30 per pound of weight saved. Proper and least cost usage must take into consideration type of fastener per application, galvanic couples and installation characteristics of protective coatings, cosmetic appearance, paint adhesion, installation forces and methods available and fatigue performance required.

  10. Joining of Gamma Titanium Aluminides

    National Research Council Canada - National Science Library

    Baeslack, William

    2002-01-01

    .... Although organized and presented by joining process, many of the observations made and relationships developed, particularly those regarding the weldability and welding metallurgy of gamma titanium...

  11. Easy come, easy go: a simple and effective orthodontic enamel anchor for endotracheal tube stabilization in a child with extensive facial burns.

    Science.gov (United States)

    Sakata, Shinichiro; Hallett, Kerrod B; Brandon, Matthew S; McBride, Craig A

    2009-11-01

    Endotracheal tube stabilization in patients with facial burns is crucial and often challenging. We present a simple method of securing an endotracheal tube using two orthodontic brackets bonded to the maxillary central incisor teeth and a 0.08'' stainless steel ligature wire. Our technique is less traumatic, and is easier to maintain oral hygiene than with previously described methods. This anchorage system takes 5 min to apply and can be removed on the ward without the need for a general anaesthetic.

  12. Chemical changes of titanium and titanium dioxide under electron bombardment

    Directory of Open Access Journals (Sweden)

    Romins Brasca

    2007-09-01

    Full Text Available The electron induced effect on the first stages of the titanium (Ti0 oxidation and titanium dioxide (Ti4+ chemical reduction processes has been studied by means of Auger electron spectroscopy. Using factor analysis we found that both processes are characterized by the appearance of an intermediate Ti oxidation state, Ti2O3 (Ti3+.

  13. Plasmonic Titanium Nitride Nanostructures via Nitridation of Nanopatterned Titanium Dioxide

    DEFF Research Database (Denmark)

    Guler, Urcan; Zemlyanov, Dmitry; Kim, Jongbum

    2017-01-01

    Plasmonic titanium nitride nanostructures are obtained via nitridation of titanium dioxide. Nanoparticles acquired a cubic shape with sharper edges following the rock-salt crystalline structure of TiN. Lattice constant of the resulting TiN nanoparticles matched well with the tabulated data. Energy...

  14. ProSeal laryngeal mask airway: An alternative to endotracheal intubation in paediatric patients for short duration surgical procedures

    Directory of Open Access Journals (Sweden)

    Jaya Lalwani

    2010-01-01

    Full Text Available The laryngeal mask airway (LMA is a supraglottic airway management device. The LMA is preferred for airway management in paediatric patients for short duration surgical procedures. The recently introduced ProSeal (PLMA, a modification of Classic LMA, has a gastric drainage tube placed lateral to main airway tube which allows the regurgitated gastric contents to bypass the glottis and prevents the pulmonary aspiration. This study was done to compare the efficacy of ProSeal LMA with an endotracheal tube in paediatric patients with respect to number of attempts for placement of devices, haemodynamic responses and perioperative respiratory complications. Sixty children, ASA I and II, weighing 10-20 kg between 2 and 8 years of age group of either sex undergoing elective ophthalmological and lower abdominal surgeries of 30-60 min duration, randomly divided into two groups of 30 patients each were studied. The number of attempts for endotracheal intubation was less than the placement of PLMA. Haemodynamic responses were significantly higher (P<0.05 after endotracheal intubation as compared to the placement of PLMA. There were no significant differences in mean SpO 2 (% and EtCO 2 levels recorded at different time intervals between the two groups. The incidence of post-operative respiratory complications cough and bronchospasm was higher after extubation than after removal of PLMA. The incidence of soft tissue trauma was noted to be higher for PLMA after its removal. There were no incidences of aspiration and hoarseness/sore throat in either group. It is concluded that ProSeal LMA can be safely considered as a suitable and effective alternative to endotracheal intubation in paediatric patients for short duration surgical procedures.

  15. Physical metallurgy of titanium alloys

    International Nuclear Information System (INIS)

    Collings, E.W.

    1988-01-01

    Researches in electric, magnetic, thermophysical properties of titanium alloys in the wide range of temperatures (from helium upto elevated one), as well as stability of phases in alloys of different types are generalized. Fundamental description of physical properties of binary model alloys is given. Acoustic emission, shape memory and Bauschinger effects, pseudoelasticity, aging and other aspects of physical metallurgy of titanium alloys are considered

  16. Randomized Pilot Trial of Two Modified Endotracheal Tubes To Prevent Ventilator-associated Pneumonia.

    Science.gov (United States)

    Deem, Steven; Yanez, David; Sissons-Ross, Laura; Broeckel, Jo Ann Elrod; Daniel, Stephen; Treggiari, Miriam

    2016-01-01

    Ventilator-associated pneumonia (VAP) is a prevalent and costly nosocomial infection related to instrumentation of the airway with an endotracheal tube (ETT), enabling microaspiration of contaminated secretions. Modification of the ETT design to reduce microaspiration and/or biofilm formation may play an important role in VAP prevention. However, there is insufficient evidence to provide strong recommendations regarding the use of modified ETT and unaddressed safety concerns. We performed a pilot randomized controlled trial comparing two modified ETTs designed specifically to prevent VAP, with the standard ETT, to test the feasibility of and inform planning for a large, pivotal, randomized trial. This study was conducted with institutional review board approval under exception from informed consent. We randomized in a blinded fashion patients undergoing emergency endotracheal intubation both out of and in hospital to receive one of three different ETT types: (1) a polyurethane-cuffed tube (PUC-ETT), (2) a polyurethane-cuffed tube equipped with a port for continuous aspiration of subglottic secretions (PUC-CASS-ETT), or a (3) standard polyvinylchloride-cuffed tube (PVC-ETT). In addition to investigating feasibility and safety, the study coprimary end points were tracheal bacterial colonization reaching a cfu count >10(6) cfu per milliliter and the incidence of invasively diagnosed VAP. A total of 102 subjects were randomized and met the eligibility criteria. Randomization procedures performed well and integrity of blinding at randomization was maintained. The majority of intubations occurred in the hospital setting (n = 77), and the remainder occurred out of hospital (n = 25). Compared with the PVC-ETT, there were no significant differences in tracheal colonization for PUC-ETT (odds ratio [OR], 0.98; 95% confidence interval [CI], 0.31-3.09) or for PUC-CASS-ETT (OR, 1.26; 95% CI, 0.42-3.76). There were no differences in the risk of invasively diagnosed VAP

  17. Fluoroscopic guidance for placing a double lumen endotracheal tube in adults.

    Science.gov (United States)

    Calenda, Emile; Baste, Jean Marc; Hajjej, Ridha; Rezig, Najiba; Moriceau, Jerome; Diallo, Yaya; Sghaeir, Slim; Danielou, Eric; Peillon, Christophe

    2014-09-01

    The aim of this study was to assess the right placement of the double lumen endotracheal tube with fluoroscopic guidance, which is used in first intention prior to the fiberscope in our institution. This was a prospective observational study. The study was conducted in vascular and thoracic operating rooms. We enrolled 205 patients scheduled for thoracic surgery, with ASA physical statuses of I (n = 37), II (n = 84), III (n = 80), and IV (n = 4). Thoracic procedures were biopsy (n = 20), wedge (n = 34), culminectomy (n = 6), lobectomy (n = 82), pneumonectomy (n = 4), sympathectomy (n = 9), symphysis (n = 47), and thymectomy (n = 3). The intubation with a double lumen tube was performed with the help of a laryngoscope. Tracheal and bronchial balloons were inflated and auscultation was performed after right and left exclusions. One shot was performed to locate the position of the bronchial tube and the hook. Fluoroscopic guidance was used to relocate the tube in case of a wrong position. When the fluoroscopic guidance failed to position the tube, a fiberscope was used. Perioperative collapse of the lung was assessed by the surgeon during the surgery. Correct fluoroscopic image was obtained after the first attempt in 58.5% of patients therefore a misplaced position was encountered in 41.5%. The fluoroscopic guidance allowed an exact repositioning in 99.5% of cases, and the mean duration of the procedure was 8 minutes. A fiberscope was required to move the hook for one patient. We did not notice a moving of the double lumen endotracheal tube during the surgery. The surgeon satisfaction was 100%. The fluoroscopy evidenced the right position of the double lumen tube and allowed a right repositioning in 99.5% of patients with a very simple implementation. Copyright © 2014. Published by Elsevier B.V.

  18. Endotracheal Tube Cuff Pressures in Patients Intubated Prior to Helicopter EMS Transport

    Directory of Open Access Journals (Sweden)

    Joseph Tennyson

    2016-11-01

    Full Text Available Introduction Endotracheal intubation is a common intervention in critical care patients undergoing helicopter emergency medical services (HEMS transportation. Measurement of endotracheal tube (ETT cuff pressures is not common practice in patients referred to our service. Animal studies have demonstrated an association between the pressure of the ETT cuff on the tracheal mucosa and decreased blood flow leading to mucosal ischemia and scarring. Cuff pressures greater than 30 cmH2O impede mucosal capillary blood flow. Multiple prior studies have recommended 30 cmH2O as the maximum safe cuff inflation pressure. This study sought to evaluate the inflation pressures in ETT cuffs of patients presenting to HEMS. Methods We enrolled a convenience sample of patients presenting to UMass Memorial LifeFlight who were intubated by the sending facility or emergency medical services (EMS agency. Flight crews measured the ETT cuff pressures using a commercially available device. Those patients intubated by the flight crew were excluded from this analysis as the cuff was inflated with the manometer to a standardized pressure. Crews logged the results on a research form, and we analyzed the data using Microsoft Excel and an online statistical analysis tool. Results We analyzed data for 55 patients. There was a mean age of 57 years (range 18–90. The mean ETT cuff pressure was 70 (95% CI= [61–80] cmH2O. The mean lies 40 cmH2O above the maximum accepted value of 30 cmH2O (p120 cmH2O, the maximum pressure on the analog gauge. Conclusion Patients presenting to HEMS after intubation by the referral agency (EMS or hospital have ETT cuffs inflated to pressures that are, on average, more than double the recommended maximum. These patients are at risk for tracheal mucosal injury and scarring from decreased mucosal capillary blood flow. Hospital and EMS providers should use ETT cuff manometry to ensure that they inflate ETT cuffs to safe pressures.

  19. Effects of shallow and deep endotracheal tube suctioning on cardiovascular indices in patients in intensive care units.

    Science.gov (United States)

    Irajpour, Alireza; Abbasinia, Mohammad; Hoseini, Abbas; Kashefi, Parviz

    2014-07-01

    Clearing the endotracheal tube through suctioning should be done to promote oxygenation. Depth of suctioning is one of the variables in this regard. In shallow suctioning method, the catheter passes to the tip of the endotracheal tube, and in deep suctioning method, it passes beyond the tip into the trachea or brunches. This study aimed to evaluate the effect of shallow and deep suctioning methods on cardiovascular indices in patients hospitalized in the intensive care units (ICUs). In this clinical trial, 74 patients were selected among those who had undergone mechanical ventilation in the ICU of Al-Zahra Hospital, Isfahan, Iran using convenience sampling method. The subjects were randomly allocated to shallow and deep suctioning groups. Heart rate (HR) and blood pressure (BP) were measured immediately before and 1, 2, and 3 min after each suctioning. Number of times of suctioning was also noted in both the groups. Data were analyzed using repeated measures analysis of variance (ANOVA), Chi-square and independent t-tests. HR and BP were significantly increased after suctioning in both the groups (P 0.05). The suctioning count was significantly higher in the shallow suctioning group than in the deep suctioning group. Shallow and deep suctioning were similar in their effects on HR and BP, but shallow suctioning caused further manipulation of patient's trachea than deep suctioning method. Therefore, in order to prevent complications, nurses are recommended to perform the endotracheal tube suctioning by the deep method.

  20. Titanium for salt water service

    International Nuclear Information System (INIS)

    Gadiyar, H.S.; Shibad, P.R.

    1980-01-01

    Titanium has potential as major material of construction in desalination plants, in condensers and heat exchangers, in view of its excellent corrosion resistance to salt water upto at least 120deg C. The advantages of titanium in such applications are brought out. The various specific problems such as pitting, crevice and galvanic corrosion and the preventive methods, for adopting titanium have been discussed. The hydriding problem can be overcome by suitably controlling the operating parameters such as temperature and surface preparation. A case has been made to prove the economic viability of titanium in comparison to Al-brass and Cu-Ni alloy. The future of titanium seems to be very promising in view of the negligible tube failures and outages. (auth.)

  1. [Evaluation of pain during mobilization and endotracheal aspiration in critical patients].

    Science.gov (United States)

    Robleda, G; Roche-Campo, F; Membrilla-Martínez, L; Fernández-Lucio, A; Villamor-Vázquez, M; Merten, A; Gich, I; Mancebo, J; Català-Puigbó, E; Baños, J E

    2016-03-01

    1) To assess the prevalence of pain during nursing care procedures, and 2) to evaluate the usefulness of certain vital signs and the bispectral index (BIS) in detecting pain. A prospective, observational analytical study was made of procedures (endotracheal aspiration and mobilization with turning) in critically ill sedated patients on mechanical ventilation. The Behavioral Pain Scale was used to assess pain, with scores of ≥3 indicating pain. Various physiological signs and BIS values were recorded, with changes of >10% being considered clinically relevant. A total of 146 procedures in 70 patients were analyzed. Pain prevalence during the procedures was 94%. Vital signs and BIS values increased significantly during the procedures compared to resting conditions, but only the changes in BIS were considered clinically relevant. In the subgroup of patients receiving preemptive analgesia prior to the procedure, pain decreased significantly compared to the group of patients who received no such analgesia (-2 [IQR: {-5}-0] vs. 3 [IQR: 1-4]; P<.001, respectively). The procedures evaluated in this study are painful. Changes in vital signs are not good indicators of pain. Changes in BIS may provide useful information about pain, but more research is needed. The administration of preemptive analgesia decreases pain during the procedures. Copyright © 2015 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.

  2. Community analysis of dental plaque and endotracheal tube biofilms from mechanically ventilated patients.

    Science.gov (United States)

    Marino, Poala J; Wise, Matt P; Smith, Ann; Marchesi, Julian R; Riggio, Marcello P; Lewis, Michael A O; Williams, David W

    2017-06-01

    Mechanically ventilated patients are at risk for developing ventilator-associated pneumonia, and it has been reported that dental plaque provides a reservoir of respiratory pathogens that may aspirate to the lungs and endotracheal tube (ETT) biofilms. For the first time, metataxonomics was used to simultaneously characterize the microbiome of dental plaque, ETTs, and non-directed bronchial lavages (NBLs) in mechanically ventilated patients to determine similarities in respective microbial communities and therefore likely associations. Bacterial 16S rRNA gene sequences from 34 samples of dental plaque, NBLs, and ETTs from 12 adult mechanically ventilated patients were analyzed. No significant differences in the microbial communities of these samples were evident. Detected bacteria were primarily oral species (e.g., Fusobacterium nucleatum, Streptococcus salivarius, Prevotella melaninogenica) with respiratory pathogens (Staphylococcus aureus, Pseudomonas aeruginosa, Streptococcuspneumoniae, and Haemophilus influenzae) also in high abundance. The high similarity between the microbiomes of dental plaque, NBLs, and ETTs suggests that the oral cavity is indeed an important site involved in microbial aspiration to the lower airway and ETT. As such, maintenance of good oral hygiene is likely to be highly important in limiting aspiration of bacteria in this vulnerable patient group. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. The concordance of ultrasound technique versus X-ray to confirm endotracheal tube position in neonates.

    Science.gov (United States)

    Chowdhry, R; Dangman, B; Pinheiro, J M B

    2015-07-01

    Given the distressingly high incidence of ETT malposition in the neonatal population, patients are exposed to ionizing radiation to confirm endotracheal tube (ETT) position. Our objective is to determine if ultrasound technique is concordant with X-ray in determining whether an ETT is deeply positioned or not. Prospective observational clinical trial. After obtaining informed consent, patients with an ETT who required X-ray for clinical reasons underwent sonographic evaluation of the ETT by an ultrasound technologist or pediatric radiologist, usually within the hour. A total of 56 image pairs were obtained from 29 patients. Ninety-eight percent of the ultrasound/X-ray image pairs were suitable for analysis. The concordance of ultrasound with X-ray to identify deeply and not deeply positioned ETTs was 95% (53/56). The sensitivity of ultrasound to detect deeply positioned ETTs on X-ray was 86% (6/7). The specificity of ultrasound to detect ETTs that were not deeply positioned on X-ray was 96% (47/49). As the largest clinical trial of its kind to date, with the greatest number of ultrasound operators, we have further established US as a feasible imaging modality to determine whether an ETT is deeply positioned or not.

  4. Severed cuff inflation tubing of endotracheal tube: A novel way to prevent cuff deflation.

    Science.gov (United States)

    Rao, Amrut K; Chaudhuri, Souvik; Joseph, Tim T; Kamble, Deependra; Gotur, Gopal; Venkatesh, Sandeep

    2014-01-01

    A well-secured endotracheal tube (ETT) is essential for safe anesthesia. The ETT has to be fixed with the adhesive plasters or with tie along with adhesive plasters appropriately. It is specially required in patients having beard, in intensive care unit (ICU) patients or in oral surgeries. If re-adjustment of the ETT is necessary, we should be cautious while removal of the plasters and tie, as there may be damage to the cuff inflation system. This can be a rare cause of ETT cuff leak, thus making maintenance of adequate ventilation difficult and requiring re-intubation. In a difficult airway scenario, it can be extremely challenging to re-intubate again. We report an incidence where the ETT cuff tubing was severed while attempting to re-adjust and re-fix the ETT and the patient required re-intubation. Retrospectively, we thought of and describe a safe, reliable and novel technique to prevent cuff deflation of the severed inflation tube. The technique can also be used to monitor cuff pressure in such scenarios.

  5. Comparison of endotracheal tube cuff pressure values before and after training seminar.

    Science.gov (United States)

    Özcan, Ayça Tuba Dumanlı; Döğer, Cihan; But, Abdülkadir; Kutlu, Işık; Aksoy, Şemsi Mustafa

    2018-06-01

    It is recommended that endotracheal cuff (ETTc) pressure be between 20 and 30 cm H 2 O. In this present study, we intend to observe average cuff pressure values in our clinic and the change in these values after the training seminar. The cuff pressure values of 200 patients intubated following general anesthesia induction in the operating theatre were measured following intubation. One hundred patients whose values were measured before the training seminar held for all physician assistants, and 100 patients whose values were measured after the training seminar were regarded as Group 1 and Group 2, respectively. Cuff pressures of both groups were recorded, and the difference between them was shown. Moreover, cuff pressure values were explored according to the working period of the physician assistants. There was no significant difference between the groups in terms of age, gender and tube diameters. Statistically significant difference was found between cuff pressure values before and after the training (p values decreased, however no statistically significant different was found (p values and potential complications.

  6. Oral and endotracheal tubes colonization by periodontal bacteria: a case-control ICU study.

    Science.gov (United States)

    Porto, A N; Cortelli, S C; Borges, A H; Matos, F Z; Aquino, D R; Miranda, T B; Oliveira Costa, F; Aranha, A F; Cortelli, J R

    2016-03-01

    Periodontal infection is a possible risk factor for respiratory disorders; however, no studies have assessed the colonization of periodontal pathogens in endotracheal tubes (ET). This case-control study analyzed whether periodontal pathogens are able to colonize ET of dentate and edentulous patients in intensive care units (ICU) and whether oral and ET periodontal pathogen profiles have any correlation between these patients. We selected 18 dentate and 18 edentulous patients from 78 eligible ICU patients. Oral clinical examination including probing depth, clinical attachment level, gingival index , and plaque index was performed by a single examiner, followed by oral and ET sampling and processing by quantitative polymerase chain reaction (total bacterial load, Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and Tannerella forsythia). Data were statistically analyzed by Mann-Whitney U, two-way analysis of variance (p Periodontal pathogens can colonize ET and the oral cavity of ICU patients. Periodontal pathogen profiles tend to be similar between dentate and edentulous ICU patients. In ICU patients, oral cavity represents a source of ET contamination. Although accompanied by higher oral bacterial levels, teeth do not seem to influence ET bacterial profiles.

  7. Incidence and endoscopic characteristics of acute laryngeal lesions in children undergoing endotracheal intubation

    Directory of Open Access Journals (Sweden)

    Eliandra da Silveira de Lima

    Full Text Available ABSTRACT INTRODUCTION: Acute laryngeal lesions after intubation appear to be precursors of chronic lesions. OBJECTIVE: To describe the incidence and type of acute laryngeal lesions after extubation in a pediatric intensive care unit (PICU. METHODS: A cohort study involving children from birth to <5 years, submitted to intubation for more than 24 h in the PICU of an university hospital. In the first eight hours after extubation, a flexible fiberoptic laryngoscopy (FFL was performed at the bedside. Those with moderate to severe abnormalities underwent a second examination seven to ten days later. RESULTS: 177 patients were included, with a median age of 2.46 months. The mean intubation time was 8.19 days. Seventy-three (41.2% patients had moderate or severe alterations at the FFL, with the remaining showing only minor alterations or normal results. During follow-up, 16 children from the group with moderate to severe lesions developed subglottic stenosis. One patient from the normal FFL group had subglottic stenosis, resulting in an incidence of 9.6% of chronic lesions. CONCLUSION: Most children in the study developed mild acute laryngeal lesions caused by endotracheal intubation, which improved in a few days after extubation.

  8. Correlation between oro and hypopharynx shape and position with endotracheal intubation difficulty

    Directory of Open Access Journals (Sweden)

    Daher Rabadi

    2014-12-01

    Full Text Available Background and objective: Prediction of intubation difficulty can save patients from major preoperative morbidity or mortality. The purpose of this paper is to assess the correlation between oro-hypo pharynx position, neck size, and length with endotracheal intubation difficulty. The study also explored the diagnostic value of Friedman Staging System in prediction cases with difficult intubation. Method: The consecutive 500 ASA (I, II adult patients undergoing elective surgery were evaluated for oro and hypopharynx shape and position by modified Mallampati, Cormack and Lehane score as well as Friedman obstructive sleep apnea classification systems. Neck circumference and length were also measured. All cases were intubated by a single anesthesiologist who was uninformed of the above evaluation and graded intubation difficulty in visual analog score. Correlation between these findings and difficulty of intubation was assessed. Sensitivity, Specificity, Positive and Negative Predictive Values were also reported. Results: Cormack-Lehane grade had the strongest correlation with difficulty of intubation followed by Friedman palate position. Friedman palate position was the most sensitive and had higher positive and negative predictive values than modified Mallampati classification. Cormack-Lehane grade was found to be the most specific with the highest negative predictive value among the four studied classifications. Conclusion: Friedman palate position is a more useful, valuable and sensitive test compared to the modified Mallampati screening test for pre-anesthetic prediction of difficult intubation where its involvement in Multivariate model may raise the accuracy and diagnostic value of preoperative assessment of difficult airway.

  9. Factors leading to self-extubation of endotracheal tubes in the intensive care unit.

    Science.gov (United States)

    Huang, Yuan-Ting

    2009-01-01

    To discuss the factors leading to self-extubation of endotracheal tubes (ETTs) and explore the differences between the groups of patients who did and did not self-remove their ETTs. Self-extubation of ETTs has been reported to occur in 4.2% of severely ill patients and is associated with adverse medical effects. A case-control study. One hundred and thirty-nine subjects were recruited from a teaching hospital in southern Taiwan based on purposive sampling. The rate of self-extubation of ETTs was 6.4%. Analysis of the two groups demonstrated that significant variables were identified and fell into three categories: (1) the department to which the patient was admitted (p self-extubation of the ETT. Among the 44 patients who had self-extubation of their ETT, 28 met the criteria to be extubated, 70% and 81.8% of whom were not sedated, and self-extubation of their ETT was conscious of the act. Of the patients who attempted to self-remove their ETT, 80% were successful and 93.2% did not incur any adverse medical effects. The medical doctor and nurse should fully evaluate a patient's oxygenation status, decrease the length of the extubation training session for patients and extubate patients promptly when extubation criteria are met. Adopting a proactive approach to patient extubation will improve the overall quality of care.

  10. Learning endotracheal intubation using a novel videolaryngoscope improves intubation skills of medical students.

    Science.gov (United States)

    Herbstreit, Frank; Fassbender, Philipp; Haberl, Helge; Kehren, Clemens; Peters, Jürgen

    2011-09-01

    Teaching endotracheal intubation to medical students is a task provided by many academic anesthesia departments. We tested the hypothesis that teaching with a novel videolaryngoscope improves students' intubation skills. We prospectively assessed in medical students (2nd clinical year) intubation skills acquired by intubation attempts in adult anesthetized patients during a 60-hour clinical course using, in a randomized fashion, either a conventional Macintosh blade laryngoscope or a videolaryngoscope (C-MAC®). The latter permits direct laryngoscopy with a Macintosh blade and provides a color image on a video screen. Skills were measured before and after the course in a standardized fashion (METI Emergency Care Simulator) using a conventional laryngoscope. All 1-semester medical students (n = 93) were enrolled. The students' performance did not significantly differ between groups before the course. After the course, students trained with the videolaryngoscope had an intubation success rate on a manikin 19% higher (95% CI 1.1%-35.3%; P incidence of "difficult (manikin) laryngoscopy" was less frequent in the group trained with the videolaryngoscope (8% vs 34%; P = 0.005). Education using a video system mounted into a traditional Macintosh blade improves intubation skills in medical students.

  11. Preparation of titanium diboride powders from titanium alkoxide and ...

    Indian Academy of Sciences (India)

    Administrator

    Department of Materials and Manufacturing Process, Malek Ashtar University of Technology, Tehran. 15875-1744, Iran ... Titanium diboride is a hard refractory material with a high melting point ... (λ = 1⋅540598 Å) radiation. Morphology of the ...

  12. Hydrogen in titanium alloys

    International Nuclear Information System (INIS)

    Wille, G.W.; Davis, J.W.

    1981-04-01

    The titanium alloys that offer properties worthy of consideration for fusion reactors are Ti-6Al-4V, Ti-6Al-2Sn-4Zr-2Mo-Si (Ti-6242S) and Ti-5Al-6Sn-2Zr-1Mo-Si (Ti-5621S). The Ti-6242S and Ti-5621S are being considered because of their high creep resistance at elevated temperatures of 500 0 C. Also, irradiation tests on these alloys have shown irradiation creep properties comparable to 20% cold worked 316 stainless steel. These alloys would be susceptible to slow strain rate embrittlement if sufficient hydrogen concentrations are obtained. Concentrations greater than 250 to 500 wppm hydrogen and temperatures lower than 100 to 150 0 C are approximate threshold conditions for detrimental effects on tensile properties. Indications are that at the elevated temperature - low hydrogen pressure conditions of the reactors, there would be negligible hydrogen embrittlement

  13. A COMPARATIVE STUDY OF 2 AGENTS, AIR AND DISTILLED WATER FOR INFLATION OF THE CUFFS OF ENDOTRACHEAL TUBES DURING LAPAROSCOPIC SURGICAL PROCEDURES UNDER GENERAL ANAESTHESIA

    Directory of Open Access Journals (Sweden)

    Sistla Gopala Krishna

    2016-03-01

    Full Text Available BACKGROUND & AIM During Nitrous Oxide+ Oxygen anaesthesia and during laparoscopic surgeries using carbon dioxide for creating pneumoperitoneum, if cuff of endotracheal tube is inflated with air, cuff pressure can rise to dangerous limits and it can produce ischemia of tracheal mucosa. Hence distilled water as an alternative agent to air for inflation of cuffs of endotracheal tubes was used for our study. Our aim is to investigate the difference in increase of intra-cuff pressure with time during laparoscopic surgical procedures under general endotracheal anaesthesia with Nitrous oxide+ Oxygen+ relaxant technique when cuffs of endotracheal tube were inflated by air & distilled water. METHODS Fifty patients (n=50 undergoing different laparoscopic surgical procedures under general endotracheal anaesthesia were randomly divided into 2 groups. In group A, air was used & in group D, distilled water was used to inflate the cuffs of endotracheal tubes. General anaesthesia was given with Nitrous oxide+ Oxygen+ relaxant technique. The intra-cuff pressures of endotracheal tube cuffs were recorded in the beginning and at the end of laparoscopic surgical procedures. Increase of pressures with time were recorded and analysed. RESULTS In group in whom we inflated the cuffs with air, there was a significant increase in intra-cuff pressures with time and there was definite diffusion of gases into the cuffs. Increase of pressure with time was statistically highly significant (P=0.00001. But in group in whom we used distilled water to inflate the cuffs, there was no change in the volume of water used for inflation and water came out of cuffs at the end of the laparoscopic surgical procedures. No additional air could be aspirated from the cuffs at the end of laparoscopic surgeries in distilled water group, indicating that there was no diffusion of gases into the cuffs or the gases diffused got dissolved in distilled water. Hence there was no increase of volume

  14. Three-finger tracheal palpation to guide endotracheal tube depth in children.

    Science.gov (United States)

    Gamble, Jonathan J; McKay, William P; Wang, Andrew F; Yip, Kinsha A; O'Brien, Jennifer M; Plewes, Christopher E

    2014-10-01

    Accurate endotracheal tube (ETT) depth is critical, especially in children. The current tools used to guide appropriate ETT depth have significant limitations. To evaluate the utility of tracheal palpation in the neck to guide appropriate ETT placement in children. A prospective observational study with a convenience sample of 50 children was conducted. During intubation, an investigator palpated the trachea with three fingertips side-by-side extending upward from the suprasternal notch. The anesthesiologist advanced the ETT slowly until palpated at the sternal notch. The investigator stated ETT palpation certainty as 'strongly felt', 'weakly felt', or 'not felt.' Final ETT position was determined by bronchoscopy and categorized as 'ETT too shallow' (tip in proximal ¼ of trachea), 'ETT too deep' (tip in distal ¼ of trachea), or 'ETT placement satisfactory' (between those extremes). Thirty boys and 20 girls undergoing dental surgery with nasal intubation were recruited (median age 4.4 years; range 2.0-10.8). The ETT (all ≥4 mm ID) was palpable at the sternal notch in all patients: 46 of 50 strongly palpable and 4 of 50 weakly palpable. The experimental methods led to satisfactory ETT placement in 49 of 50 patients, too deep in 1 of 50 patients. Compared with the Pediatrics Advanced Life Support (PALS) predictive formula, satisfactory placement would have been 41 of 50 patients (P guide ETT placement has excellent clinical performance and better guides appropriate ETT depth than the PALS formula in our study population. © 2014 John Wiley & Sons Ltd.

  15. Incremental change in cross sectional area in small endotracheal tubes: A call for more size options.

    Science.gov (United States)

    Mortelliti, Caroline L; Mortelliti, Anthony J

    2016-08-01

    To elucidate the relatively large incremental percent change (IPC) in cross sectional area (CSA) in currently available small endotracheal tubes (ETTs), and to make recommendation for lesser incremental change in CSA in these smaller ETTs, in order to minimize iatrogenic airway injury. The CSAs of a commercially available line of ETTs were calculated, and the IPC of the CSA between consecutive size ETTs was calculated and graphed. The average IPC in CSA with large ETTs was applied to calculate identical IPC in the CSA for a theoretical, smaller ETT series, and the dimensions of a new theoretical series of proposed small ETTs were defined. The IPC of CSA in the larger (5.0-8.0 mm inner diameter (ID)) ETTs was 17.07%, and the IPC of CSA in the smaller ETTs (2.0-4.0 mm ID) is remarkably larger (38.08%). Applying the relatively smaller IPC of CSA from larger ETTs to a theoretical sequence of small ETTs, starting with the 2.5 mm ID ETT, suggests that intermediate sizes of small ETTs (ID 2.745 mm, 3.254 mm, and 3.859 mm) should exist. We recommend manufacturers produce additional small ETT size options at the intuitive intermediate sizes of 2.75 mm, 3.25 mm, and 3.75 mm ID in order to improve airway management for infants and small children. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Endotracheal tubes and fluid aspiration: an in vitro evaluation of new cuff technologies.

    Science.gov (United States)

    Mariyaselvam, Maryanne Z; Marsh, Lucy L; Bamford, Sarah; Smith, Ann; Wise, Matt P; Williams, David W

    2017-03-04

    Aspiration of subglottic secretions past the endotracheal tube (ETT) cuff is a prerequisite for developing ventilator-associated pneumonia (VAP). Subglottic secretion drainage (SSD) ETTs reduce aspiration of subglottic secretions and have demonstrated lower VAP rates. We compared the performance of seven SSD ETTs against a non-SSD ETT in preventing aspiration below inflated cuffs. ETTs were positioned vertically in 2 cm diameter cylinders. Four ml of a standard microbial suspension was added above inflated cuffs. After 1 h, aspiration was measured and ETTs demonstrating no leakage were subjected to rotational movement and evaluation over 24 h. Collected aspirated fluid was used to inoculate agar media and incubated aerobically at 37 °C for 24 h. The aspiration rate, volume and number of microorganisms that leaked past the cuff was measured. Experiments were repeated (×10) for each type of ETT, with new ETTs used for each repeat. Best performing ETTs were then tested in five different cylinder diameters (1.6, 1.8, 2.0, 2.2 and 2.4 cm). Experiments were repeated as above using sterile water. Volume and time taken for aspiration past the cuff was measured. Experiments were repeated (×10) for each type of ETT. Results were analysed using non-parametric tests for repeated measures. The PneuX ETT prevented aspiration past the cuff in all experiments. All other ETTs allowed aspiration, with considerable variability in performance. The PneuX ETT was statistically superior in reducing aspiration compared to the SealGuard (p aspiration across the range of diameters compared to the SealGuard (p aspiration, relating to cuff material and design. Variability in performance was likely due to the random manner in which involutional folds form in the inflated ETT cuff. The PneuX ETT was the only ETT able to consistently prevent aspiration past the cuff in all experiments.

  17. Resuscitation Prior to Emergency Endotracheal Intubation: Results of a National Survey

    Directory of Open Access Journals (Sweden)

    Robert S. Green

    2016-09-01

    Full Text Available Introduction: Respiratory failure is a common problem in emergency medicine (EM and critical care medicine (CCM. However, little is known about the resuscitation of critically ill patients prior to emergency endotracheal intubation (EETI. Our aim was to describe the resuscitation practices of EM and CCM physicians prior to EETI. Methods: A cross-sectional survey was developed and tested for content validity and retest reliability by members of the Canadian Critical Care Trials Group. The questionnaire was distributed to all EM and CCM physician members of three national organizations. Using three clinical scenarios (trauma, pneumonia, congestive heart failure, we assessed physician preferences for use and types of fluid and vasopressor medication in pre-EETI resuscitation of critically ill patients. Results: In total, 1,758 physicians were surveyed (response rate 50.2%, 882/1,758. Overall, physicians would perform pre-EETI resuscitation using either fluids or vasopressors in 54% (1,193/2,203 of cases. Most physicians would “always/often” administer intravenous fluid pre-EETI in the three clinical scenarios (81%, 1,484/1,830. Crystalloids were the most common fluid physicians would “always/often” administer in congestive heart failure (EM 43%; CCM 44%, pneumonia (EM 97%; CCM 95% and trauma (EM 96%; CCM 96%. Pre-EETI resuscitation using vasopressors was uncommon (4.9%. Training in CCM was associated with performing pre-EETI resuscitation (odds ratio, 2.20; 95% CI, [1.44-3.36], p<0.001. Conclusion: Pre-EETI resuscitation is common among Canadian EM and CCM physicians. Most physicians use crystalloids pre-EETI as a resuscitation fluid, while few would give vasopressors. Physicians with CCM training were more likely to perform pre-EETI resuscitation.

  18. Apneic oxygenation reduces hypoxemia during endotracheal intubation in the pediatric emergency department.

    Science.gov (United States)

    Vukovic, Adam A; Hanson, Holly R; Murphy, Shelley L; Mercurio, Danielle; Sheedy, Craig A; Arnold, Donald H

    2018-04-18

    Apneic oxygenation (AO) has been evaluated in adult patients as a means of reducing hypoxemia during endotracheal intubation (ETI). While less studied in pediatric patients, its practice has been largely adopted. Determine association between AO and hypoxemia in pediatric patients undergoing ETI. Observational study at an urban, tertiary children's hospital emergency department. Pediatric patients undergoing ETI were examined during eras without (January 2011-June 2011) and with (August 2014-March 2017) apneic oxygenation. The primary outcome was hypoxemia, defined as pulse oximetry (SpO 2 ) < 90%. The χ 2 and Wilcoxon rank-sum tests examined differences between cohorts. Multivariable regression models examined adjusted associations between covariates and hypoxemia. 149 patients were included. Cohorts were similar except for greater incidence of altered mental status in those receiving AO (26% vs. 7%, p = 0.03). Nearly 50% of the pre-AO cohort experienced hypoxemia during ETI, versus <25% in the AO cohort. Median [IQR] lowest SpO 2 during ETI was 93 (69, 99) for pre-AO and 100 [95, 100] for the AO cohort (p < 0.001). In a multivariable logistic regression model, hypoxemia during ETI was associated with AO (aOR 0.3, 95% confidence interval [CI] 0.1-0.8), increased age (for 1 year, aOR 0.8, 95% CI 0.7-1.0), lowest SpO 2 before ETI (for 1% increase, aOR 0.9, 95% CI 0.8-1.0), and each additional intubation attempt (aOR 4.0, 95% CI 2.2-7.2). Apneic oxygenation is an easily-applied intervention associated with decreases in hypoxemia during pediatric ETI. Nearly 50% of children not receiving AO experienced hypoxemia. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Thermomechanical treatment of titanium alloys

    International Nuclear Information System (INIS)

    Khorev, A.K.

    1979-01-01

    The problems of the theory and practical application of thermomechanical treatment of titanium alloys are presented. On the basis of the systematic investigations developed are the methods of thermomechanical treatment of titanium alloys, established are the optimum procedures and produced are the bases of their industrial application with an account of alloy technological peculiarities and the procedure efficiency. It is found that those strengthening methods are more efficient at which the contribution of dispersion hardening prevails over the strengthening by phase hardening

  20. COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE

    Directory of Open Access Journals (Sweden)

    Muhaji

    2017-12-01

    Full Text Available Background: Endotracheal suctioning is one of the common supportive measures in intensive care units (ICU, which may be related to complications such as hypoxia. However, a questionable efficacy is still identified to choose suctioning pressure between 130 mmHg and 140 mmHg that is effective for patients with endotracheal tube. Objective: To compare the effectiveness of 130 mmHg and 140 mmHg suctioning pressure on oxygen saturation in patients with endotracheal tube. Methods: This research used a quasy experimental design with pretest and posttest group. The study was conducted from 31 January to 1 March 2017 in the Hospital of Panti Wilasa Citarum and Hospital of Roemani Muhammadiyah Semarang. There were 30 samples recruited using consecutive sampling, with 15 assigned in the 130 mmHg and 140 mmHg suctioning pressure group. Pulse oximetry was used to measure oxygen saturation. Paired t-test and Independent t-test were used for data analysis. Results: Findings showed that there was a statistically significant effect of 130 and 140 mmHg suctioning pressure on oxygen saturation in patients with ETT with p-value <0.05. There was a significant mean difference of oxygen saturation between 130 mmHg and 140 mmHg suctioning pressure group with p-value 0.004 (<0.05. The mean difference of oxygen saturation between both groups was 13.157. Conclusion: The 140 mmHg suctioning pressure is more effective compared with 130 mmHg suctioning pressure in increasing oxygen saturation in patients with ETT.

  1. Deep Convolutional Neural Networks for Endotracheal Tube Position and X-ray Image Classification: Challenges and Opportunities.

    Science.gov (United States)

    Lakhani, Paras

    2017-08-01

    The goal of this study is to evaluate the efficacy of deep convolutional neural networks (DCNNs) in differentiating subtle, intermediate, and more obvious image differences in radiography. Three different datasets were created, which included presence/absence of the endotracheal (ET) tube (n = 300), low/normal position of the ET tube (n = 300), and chest/abdominal radiographs (n = 120). The datasets were split into training, validation, and test. Both untrained and pre-trained deep neural networks were employed, including AlexNet and GoogLeNet classifiers, using the Caffe framework. Data augmentation was performed for the presence/absence and low/normal ET tube datasets. Receiver operating characteristic (ROC), area under the curves (AUC), and 95% confidence intervals were calculated. Statistical differences of the AUCs were determined using a non-parametric approach. The pre-trained AlexNet and GoogLeNet classifiers had perfect accuracy (AUC 1.00) in differentiating chest vs. abdominal radiographs, using only 45 training cases. For more difficult datasets, including the presence/absence and low/normal position endotracheal tubes, more training cases, pre-trained networks, and data-augmentation approaches were helpful to increase accuracy. The best-performing network for classifying presence vs. absence of an ET tube was still very accurate with an AUC of 0.99. However, for the most difficult dataset, such as low vs. normal position of the endotracheal tube, DCNNs did not perform as well, but achieved a reasonable AUC of 0.81.

  2. Titanium nanostructures for biomedical applications

    International Nuclear Information System (INIS)

    Kulkarni, M; Gongadze, E; Perutkova, Š; A Iglič; Mazare, A; Schmuki, P; Kralj-Iglič, V; Milošev, I; Mozetič, M

    2015-01-01

    Titanium and titanium alloys exhibit a unique combination of strength and biocompatibility, which enables their use in medical applications and accounts for their extensive use as implant materials in the last 50 years. Currently, a large amount of research is being carried out in order to determine the optimal surface topography for use in bioapplications, and thus the emphasis is on nanotechnology for biomedical applications. It was recently shown that titanium implants with rough surface topography and free energy increase osteoblast adhesion, maturation and subsequent bone formation. Furthermore, the adhesion of different cell lines to the surface of titanium implants is influenced by the surface characteristics of titanium; namely topography, charge distribution and chemistry. The present review article focuses on the specific nanotopography of titanium, i.e. titanium dioxide (TiO 2 ) nanotubes, using a simple electrochemical anodisation method of the metallic substrate and other processes such as the hydrothermal or sol-gel template. One key advantage of using TiO 2 nanotubes in cell interactions is based on the fact that TiO 2 nanotube morphology is correlated with cell adhesion, spreading, growth and differentiation of mesenchymal stem cells, which were shown to be maximally induced on smaller diameter nanotubes (15 nm), but hindered on larger diameter (100 nm) tubes, leading to cell death and apoptosis. Research has supported the significance of nanotopography (TiO 2 nanotube diameter) in cell adhesion and cell growth, and suggests that the mechanics of focal adhesion formation are similar among different cell types. As such, the present review will focus on perhaps the most spectacular and surprising one-dimensional structures and their unique biomedical applications for increased osseointegration, protein interaction and antibacterial properties. (topical review)

  3. Titanium nanostructures for biomedical applications

    Science.gov (United States)

    Kulkarni, M.; Mazare, A.; Gongadze, E.; Perutkova, Š.; Kralj-Iglič, V.; Milošev, I.; Schmuki, P.; Iglič, A.; Mozetič, M.

    2015-02-01

    Titanium and titanium alloys exhibit a unique combination of strength and biocompatibility, which enables their use in medical applications and accounts for their extensive use as implant materials in the last 50 years. Currently, a large amount of research is being carried out in order to determine the optimal surface topography for use in bioapplications, and thus the emphasis is on nanotechnology for biomedical applications. It was recently shown that titanium implants with rough surface topography and free energy increase osteoblast adhesion, maturation and subsequent bone formation. Furthermore, the adhesion of different cell lines to the surface of titanium implants is influenced by the surface characteristics of titanium; namely topography, charge distribution and chemistry. The present review article focuses on the specific nanotopography of titanium, i.e. titanium dioxide (TiO2) nanotubes, using a simple electrochemical anodisation method of the metallic substrate and other processes such as the hydrothermal or sol-gel template. One key advantage of using TiO2 nanotubes in cell interactions is based on the fact that TiO2 nanotube morphology is correlated with cell adhesion, spreading, growth and differentiation of mesenchymal stem cells, which were shown to be maximally induced on smaller diameter nanotubes (15 nm), but hindered on larger diameter (100 nm) tubes, leading to cell death and apoptosis. Research has supported the significance of nanotopography (TiO2 nanotube diameter) in cell adhesion and cell growth, and suggests that the mechanics of focal adhesion formation are similar among different cell types. As such, the present review will focus on perhaps the most spectacular and surprising one-dimensional structures and their unique biomedical applications for increased osseointegration, protein interaction and antibacterial properties.

  4. Novel device (AirWave) to assess endotracheal tube migration: a pilot study.

    Science.gov (United States)

    Nacheli, Gustavo Cumbo; Sharma, Manish; Wang, Xiaofeng; Gupta, Amit; Guzman, Jorge A; Tonelli, Adriano R

    2013-08-01

    Little is known about endotracheal tube (ETT) migration during routine care among critically ill patients. AirWave is a novel device that uses sonar waves to measure ETT migration and obstructions in real time. The aim of the present study is to assess the accuracy of the AirWave to evaluate ETT migration. In addition, we determined the degree of variation in ETT position and tested whether more pronounced migration occurs in specific clinical scenarios. After institutional review board approval, we included mechanically ventilated patients from February 2012 to May 2012. A chest radiography (CXR) was obtained at baseline and 24 hours when clinically indicated. The ETT distance at the lips was recorded at baseline and every 4 hours. The AirWave system continuously recorded ETT position changes from baseline, and luminal obstructions. A total of 42 patients (age: 61 [SD ±13] years, men: 52%) were recruited. A total of 19 patients had measurements of ETT migration at 24 hours by the 3 methodologies used in this study. The mean (SD) of the ETT migration at 24 hours was +0.04 (1.2), -0.42 (0.7) and +0.34 (1.81) cm when measured by portable CXR, ETT distance at the teeth and AirWave device, respectively. Bland-Altman analysis of tube migration at 24 hours comparing the AirWave with CXR readings showed a bias of 0.1 cm with 95% limit of agreement of -3.8 and +4.3 cm. Comparison of tube migration at 24 hours determined by AirWave with ETT distance at the lips revealed a bias of -0.4 with 95% limit of agreement -3.7 to +3 cm, similar to the values observed between CXR and ETT distance at the lips (bias of -0.3 cm, 95% limit of agreement of -3.4 to +2.8 cm). Factors associated with ETT migration at 24 hours were ETT size and initial measurement from ETT tip to carina by portable CXR. AirWave detected in eight patients some degree of ETT obstruction (30% ± 9.6%) that resolved with prompt ETT catheter suction. The AirWave may provide useful information regarding ETT

  5. Endotracheal intubation in patients with difficult airway: Using laryngeal mask airway with bougie versus video laryngoscopy

    Directory of Open Access Journals (Sweden)

    Hesameddin Modir

    2017-01-01

    Full Text Available Airway management is essential for safe anesthesia and endotracheal intubation is the most important procedure by which critically ill patients can be better managed, especially if done quickly and successfully. This study aimed to compare the techniques of intubation through laryngeal mask airway (LMA using a bougie versus video laryngoscopy (VL regarding to intubation success and the quality of intubation indices in patients with difficult airways. This randomized clinical trial was performed on 96 patients aged 16–76 years with Mallampati class 3 or 4 who underwent elective surgery. Once the demographics were recorded, patients were randomly divided into two groups and the first group intubated with VL, and the second group intubated through laryngeal mask using a bougie. Then vital signs, arterial oxygen saturation, the time required for successful intubation, and ease of intubation were recorded. Here t-tests, chi-square, Fisher exact tests, and analysis of variance for repeated measurement were used to analyze the data in SPSS software. The overall success rates of intubation in VL and LMA groups were 46 (96% and 44 (92%, respectively. The mean duration of intubation for the LMA and VL groups was 18.70 ± 6.73 and 14.21 ± 4.14 seconds, respectively (P < 0.001. Moreover, visual analogue scale score for pain in throat was significantly lower in VL group than LMA (1.65 ± 0.76 vs. 1.33 ± 0.52. Moreover, easy intubation in bougie group was 50%, while the easy intubation in VL was 73% (P = 0.023. In addition, incidence of cough was 31% in the LMA with bougie group and 9% in VL group (P = 0.005. The VL technique is an easier method and has a shorter intubation time than LMA using bougie, and causes a lower incidence of coughing, laryngospasm in patients that need intubation. Moreover, cough and discomfort in the throat tend to be less in VL, and the LMA could be used as replacement of VL in hard situations.

  6. An expiratory assist during spontaneous breathing can compensate for endotracheal tube resistance.

    Science.gov (United States)

    Uchiyama, Akinori; Chang, Cheng; Suzuki, Shinya; Mashimo, Takashi; Fujino, Yuji

    2009-08-01

    Although inspiratory assist of spontaneous breathing in intubated patients is common, expiratory assist functions have rarely been reported. Effective expiratory support (ES) could be used to compensate for endotracheal tube (ETT) resistance during spontaneous breathing. In this study, we examined the performance of a new system designed to provide both inspiratory support (IS) and ES during spontaneous breathing with the goal of reducing the effective resistance of the ETT. The ES system consisted of a ventilator demand valve and a computer-controlled piston cylinder, which aspirated gas from the respiratory circuit during the expiratory phase. The movement of the piston was synchronized with spontaneous breathing. We compared the pressures at the tip of the ETT and in the breathing circuit during spontaneous breathing through an ETT of internal diameter (ID) 5 mm with that of an ETT with ID 8 mm in nine healthy adult male volunteers. The ventilatory mode was set to maintain a continuous airway pressure of 0 cm H(2)O. Three ventilator settings (no support, IS only, and IS plus ES) were compared using ID 5 mm ETT. We monitored pressure in the breathing circuit (P(aw)), ETT tip pressure (P(tip)), and respiratory flow. The P(tip) of the ID 5 mm ETT showed a large negative deflection during inspiration and a positive deflection during expiration without support. IS alone did not improve the respiratory pattern through the small ETT. However, IS plus ES resulted in negative P(aw) during expiration in addition to positive deflection of P(aw) during inspiration, making the pressure characteristics of P(tip) similar to those of ID 8 mm ETT. Moreover, IS plus ES produced a respiratory pattern through the ID 5 mm ETT that was similar to that through the ID 8 mm ETT. In this study of healthy volunteers, IS plus ES compensated for the airway resistance imposed by a ID 5.0 mm ETT to create pressure changes at the tip of the ETT similar to those of an ID 8.0 mm ETT.

  7. CO2 driven endotracheal tube cuff control in critically ill patients: A randomized controlled study.

    Science.gov (United States)

    De Pascale, Gennaro; Pennisi, Mariano Alberto; Vallecoccia, Maria Sole; Bello, Giuseppe; Maviglia, Riccardo; Montini, Luca; Di Gravio, Valentina; Cutuli, Salvatore Lucio; Conti, Giorgio; Antonelli, Massimo

    2017-01-01

    To determine the safety and clinical efficacy of an innovative integrated airway system (AnapnoGuard™ 100 system) that continuously monitors and controls the cuff pressure (Pcuff), while facilitating the aspiration of subglottic secretions (SS). This was a prospective, single centre, open-label, randomized, controlled feasibility and safety trial. The primary endpoint of the study was the rate of device related adverse events (AE) and serious AE (SAE) as a result of using AnapnoGuard (AG) 100 during mechanical ventilation. Secondary endpoints were: (1) mechanical complications rate (2) ICU staff satisfaction; (3) VAP occurrence; (4) length of mechanical ventilation; (5) length of Intensive Care Unit stay and mortality; (6) volume of evacuated subglottic secretions. Sixty patients were randomized to be intubated with the AG endotracheal-tube (ETT) and connected to the AG 100 system allowing Pcuff adjustment and SS aspiration; or with an ETT combined with SS drainage and Pcuff controlled manually. No difference in adverse events rate was identified between the groups. The use of AG system was associated with a significantly higher incidence of Pcuff determinations in the safety range (97.3% vs. 71%; paspirated SS secretions: (192.0[64-413] ml vs. 150[50-200], p = 0.19 (total)); (57.8[20-88.7] ml vs. 50[18.7-62] ml, p = 0.11 (daily)). No inter-group difference was detected using AG system vs. controls in terms of post-extubation throat pain level (0 [0-2] vs. 0 [0-3]; p = 0.7), hoarseness (42.9% vs. 75%; p = 0.55) and tracheal mucosa oedema (16.7% vs. 10%; p = 0.65). Patients enrolled in the AG group had a trend to reduced VAP risk of ventilator-associated pneumonia(VAP) (14.8% vs. 40%; p = 0.06), which were more frequently monomicrobial (25% vs. 70%; p = 0.03). No statistically significant difference was observed in duration of mechanical ventilation, ICU stay, and mortality. The use AG 100 system and AG tube in critically ill intubated patients is safe and

  8. CO2 driven endotracheal tube cuff control in critically ill patients: A randomized controlled study.

    Directory of Open Access Journals (Sweden)

    Gennaro De Pascale

    Full Text Available To determine the safety and clinical efficacy of an innovative integrated airway system (AnapnoGuard™ 100 system that continuously monitors and controls the cuff pressure (Pcuff, while facilitating the aspiration of subglottic secretions (SS.This was a prospective, single centre, open-label, randomized, controlled feasibility and safety trial. The primary endpoint of the study was the rate of device related adverse events (AE and serious AE (SAE as a result of using AnapnoGuard (AG 100 during mechanical ventilation. Secondary endpoints were: (1 mechanical complications rate (2 ICU staff satisfaction; (3 VAP occurrence; (4 length of mechanical ventilation; (5 length of Intensive Care Unit stay and mortality; (6 volume of evacuated subglottic secretions. Sixty patients were randomized to be intubated with the AG endotracheal-tube (ETT and connected to the AG 100 system allowing Pcuff adjustment and SS aspiration; or with an ETT combined with SS drainage and Pcuff controlled manually.No difference in adverse events rate was identified between the groups. The use of AG system was associated with a significantly higher incidence of Pcuff determinations in the safety range (97.3% vs. 71%; p<0.01 and a trend to a greater volume of aspirated SS secretions: (192.0[64-413] ml vs. 150[50-200], p = 0.19 (total; (57.8[20-88.7] ml vs. 50[18.7-62] ml, p = 0.11 (daily. No inter-group difference was detected using AG system vs. controls in terms of post-extubation throat pain level (0 [0-2] vs. 0 [0-3]; p = 0.7, hoarseness (42.9% vs. 75%; p = 0.55 and tracheal mucosa oedema (16.7% vs. 10%; p = 0.65. Patients enrolled in the AG group had a trend to reduced VAP risk of ventilator-associated pneumonia(VAP (14.8% vs. 40%; p = 0.06, which were more frequently monomicrobial (25% vs. 70%; p = 0.03. No statistically significant difference was observed in duration of mechanical ventilation, ICU stay, and mortality.The use AG 100 system and AG tube in critically ill

  9. Titanium pigmentation. An electron probe microanalysis study

    International Nuclear Information System (INIS)

    Dupre, A.; Touron, P.; Daste, J.; Lassere, J.; Bonafe, J.L.; Viraben, R.

    1985-01-01

    A patient had an unusual pigmentary disease induced by titanium dioxide. The use of a topical cream containing titanium dioxide caused a xanthomalike appearance on the patient's penis. Electron probe microanalysis was valuable in establishing the cause of this balanitis

  10. Printing of Titanium implant prototype

    International Nuclear Information System (INIS)

    Wiria, Florencia Edith; Shyan, John Yong Ming; Lim, Poon Nian; Wen, Francis Goh Chung; Yeo, Jin Fei; Cao, Tong

    2010-01-01

    Dental implant plays an important role as a conduit of force and stress to flow from the tooth to the related bone. In the load sharing between an implant and its related bone, the amount of stress carried by each of them directly related to their stiffness or modulus. Hence, it is a crucial issue for the implant to have matching mechanical properties, in particular modulus, between the implant and its related bone. Titanium is a metallic material that has good biocompatibility and corrosion resistance. Whilst the modulus of the bulk material is still higher than that of bone, it is the lowest among all other commonly used metallic implant materials, such as stainless steel or cobalt alloy. Hence it is potential to further reduce the modulus of pure Titanium by engineering its processing method to obtain porous structure. In this project, porous Titanium implant prototype is fabricated using 3-dimensional printing. This technique allows the flexibility of design customization, which is beneficial for implant fabrication as tailoring of implant size and shape helps to ensure the implant would fit nicely to the patient. The fabricated Titanium prototype had a modulus of 4.8-13.2 GPa, which is in the range of natural bone modulus. The compressive strength achieved was between 167 to 455 MPa. Subsequent cell culture study indicated that the porous Titanium prototype had good biocompatibility and is suitable for bone cell attachment and proliferation.

  11. High-fidelity simulation of lung isolation with double-lumen endotracheal tubes and bronchial blockers in anesthesiology resident training.

    Science.gov (United States)

    Failor, Erin; Bowdle, Andrew; Jelacic, Srdjan; Togashi, Kei

    2014-08-01

    Demonstrate the feasibility of using the AirSim Bronchi airway simulator to teach residents how to manage lung isolation with double-lumen endotracheal tubes and bronchial blockers and evaluate their performance with a detailed checklist. Prospective observational study. University anesthesiology residency training program. Anesthesiology residents taking a cardiothoracic anesthesiology rotation. Residents were instructed in 7 tasks using the AirSim Bronchi: The use of the fiberoptic bronchoscope, methods for placing left and right double-lumen endotracheal tubes and 3 bronchial blockers (Univent, Arndt, and Cohen), and application of continuous positive airway pressure (CPAP) to the unventilated lung. Two to 3 weeks later, checklists and a detailed scoring system were used to assess performance. Residents rated the curriculum and their own confidence in performing the tasks using a 5-point Likert scale. Thirteen residents completed the curriculum. Their median Likert scale ratings of the curriculum based on a questionnaire with 6 items ranged from 4 to 5 of 5. Resident confidence scores for each lung isolation technique improved after the simulation training, with the median gain ranging from 0.5 to 1.5 Likert levels depending on the task. The largest improvement occurred with the bronchial blockers (psimulator in a novel simulation curriculum to teach lung-isolation techniques to anesthesiology residents and evaluated performance using a detailed checklist scoring system. This curriculum is a promising educational tool. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Bedside screen for oral cavity structure, salivary flow, and vocal production over the 14days following endotracheal extubation.

    Science.gov (United States)

    Chen, Cheryl Chia-Hui; Wu, Kuo-Hsiang; Ku, Shih-Chi; Chan, Ding-Cheng; Lee, Jang-Jaer; Wang, Tyng-Guey; Hsiao, Tzu-Yu

    2018-06-01

    To describe the sequelae of oral endotracheal intubation by evaluating prevalence rates of structural injury, hyposalivation, and impaired vocal production over 14days following extubation. Consecutive adults (≥20years, N=114) with prolonged (≥48h) endotracheal intubation were enrolled from medical intensive care units at a university hospital. Participants were assessed by trained nurses at 2, 7, and 14days after extubation, using a standardized bedside screening protocol. Within 48-hour postextubation, structural injuries were common, with 51% having restricted mouth opening. Unstimulated salivary flow was reduced in 43%. For vocal production, 51% had inadequate breathing support for phonation, dysphonia was common (94% had hoarseness and 36% showed reduced efficiency of vocal fold closure), and >40% had impaired articulatory precision. By 14days postextubation, recovery was noted in most conditions, but reduced efficiency of vocal fold closure persisted. Restricted mouth opening (39%) and reduced salivary flow (34%) remained highly prevalent. After extubation, restricted mouth opening, reduced salivary flow, and dysphonia were common and prolonged in recovery. Reduced efficiency of vocal cord closure persisted at 14days postextubation. The extent and duration of these sequelae remind clinicians to screen for them up to 2weeks after extubation. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Anodic growth of titanium dioxide nanostructures

    DEFF Research Database (Denmark)

    2010-01-01

    Disclosed is a method of producing nanostructures of titanium dioxide (TiO 2 ) by anodisation of titanium (Ti) in an electrochemical cell, comprising the steps of: immersing a non-conducting substrate coated with a layer of titanium, defined as the anode, in an electrolyte solution...... an electrical contact to the layer of titanium on the anode, where the electrical contact is made in the electrolyte solution...

  14. Uranium fluorides analysis. Titanium spectrophotometric determination

    International Nuclear Information System (INIS)

    Anon.

    Titanium determination in uranium hexafluoride in the range 0.7 to 100 microgrammes after transformation of uranium fluoride in sulfate. Titanium is separated by extraction with N-benzoylphenylhydroxylamine, reextracted by hydrochloric-hydrofluoric acid. The complex titanium-N-benzoylphenylhydroxylamine is extracted by chloroform. Spectrophotometric determination at 400 nm [fr

  15. 21 CFR 73.1575 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.1575 Section 73.1575 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Drugs § 73.1575 Titanium dioxide. (a) Identity and specifications. (1) The color additive titanium dioxide shall conform in identity and specifications to the requirements...

  16. 40 CFR 180.1195 - Titanium dioxide.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Titanium dioxide. 180.1195 Section 180.1195 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS... Titanium dioxide. Titanium dioxide is exempted from the requirement of a tolerance for residues in or on...

  17. 21 CFR 73.2575 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.2575 Section 73.2575 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Cosmetics § 73.2575 Titanium dioxide. (a) Identity and specifications. The color additive titanium dioxide shall conform in identity and specifications to the requirements...

  18. 21 CFR 73.575 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.575 Section 73.575 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Foods § 73.575 Titanium dioxide. (a) Identity. (1) The color additive titanium dioxide is synthetically prepared TiO2, free from admixture with other substances. (2) Color...

  19. 21 CFR 73.3126 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.3126 Section 73.3126 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Medical Devices § 73.3126 Titanium dioxide. (a) Identity and specifications. The color additive titanium dioxide (CAS Reg. No. 13463-67-7), Color Index No. 77891, shall...

  20. Adaptive mesh refinement in titanium

    Energy Technology Data Exchange (ETDEWEB)

    Colella, Phillip; Wen, Tong

    2005-01-21

    In this paper, we evaluate Titanium's usability as a high-level parallel programming language through a case study, where we implement a subset of Chombo's functionality in Titanium. Chombo is a software package applying the Adaptive Mesh Refinement methodology to numerical Partial Differential Equations at the production level. In Chombo, the library approach is used to parallel programming (C++ and Fortran, with MPI), whereas Titanium is a Java dialect designed for high-performance scientific computing. The performance of our implementation is studied and compared with that of Chombo in solving Poisson's equation based on two grid configurations from a real application. Also provided are the counts of lines of code from both sides.

  1. The titanium oxide phi system

    Science.gov (United States)

    Galehouse, D. C.; Davis, S. P.

    1980-01-01

    The phy system of titanium oxide has been studied in emission in the near-infrared, with the Fourier transform spectrometer at a resolution of 8000,000. Approximately 3000 lines from 25 bands of this system have been identified, including all five 0-0 and 0-1 bands corresponding to the five natural titanium isotopes. Eleven vibrational levels have been observed, and all bands have been rotationally analyzed. Band intensities are agreement with known isotopic abundances and calculated Franck-Condon factors.

  2. Differential Effects of Endotracheal Suctioning on Gas Exchanges in Patients with Acute Respiratory Failure under Pressure-Controlled and Volume-Controlled Ventilation

    Directory of Open Access Journals (Sweden)

    Xiao-Wei Liu

    2015-01-01

    Full Text Available This study was conducted to evaluate the effects of open endotracheal suctioning on gas exchange and respiratory mechanics in ARF patients under the modes of PCV or VCV. Ninety-six ARF patients were treated with open endotracheal suctioning and their variations in respiratory mechanics and gas exchange after the suctions were compared. Under PCV mode, compared with the initial level of tidal volume (VT, ARF patients showed 30.0% and 27.8% decrease at 1 min and 10 min, respectively. Furthermore, the initial respiratory system compliance (Crs decreased by 29.6% and 28.5% at 1 min and 10 min, respectively. Under VCV mode, compared with the initial level, 38.6% and 37.5% increase in peak airway pressure (PAP were found at 1 min and 10 min, respectively. Under PCV mode, the initial PaO2 increased by 6.4% and 10.2 % at 3 min and 10 min, respectively, while 18.9% and 30.6% increase of the initial PaO2 were observed under VCV mode. Summarily, endotracheal suctioning may impair gas exchange and decrease lung compliance in ARF patients receiving mechanical ventilation under both PCV and VCV modes, but endotracheal suctioning effects on gas exchange were more severe and longer-lasting under PCV mode than VCV.

  3. A comparison between the v-gel supraglottic airway device and the cuffed endotracheal tube for airway management in spontaneously breathing cats during isoflurane anaesthesia

    NARCIS (Netherlands)

    van Oostrom, H.; Krauss, M.W.; Sap, R.

    2013-01-01

    Abstract OBJECTIVE: To compare airway management using the v-gel supraglottic airway device (v-gel SGAD) to that using an endotracheal tube (ETT), with respect to practicability, leakage of volatile anaesthetics and upper airway discomfort in cats. STUDY DESIGN: Prospective, randomized clinical

  4. The Effect of Progressive Muscle Relaxation Exercises After Endotracheal Extubation on Vital Signs and Anxiety Level in Open Heart Surgery Patients

    Directory of Open Access Journals (Sweden)

    Özlem İbrahimoğlu

    2017-12-01

    Full Text Available Objective: The purpose of this study was to examine the effects of the exercises of progressive muscle relaxation (PMR on vital signs and anxiety level after endotracheal extubation in open heart surgery. Materials and Methods: This study was carried out as quasi-experimental, pre-test, and post-test with a control group. The study recruited 30 experimental and 30 control group open heart surgery patients, who met the inclusion criteria, from a cardiac and vascular surgery clinic of a university hospital. PMR exercises, which were taught before the surgery, were implemented after the surgery in the intensive care unit simultaneously with endotracheal extubation. The vital signs of the patients were monitored for the first 30 min. The anxiety levels were measured after 30 min of extubation with state anxiety inventory. Results: The lower rates of heartbeat, breathing, arterial blood pressure, and anxiety were observed in the experimental group in all measurements (first 30 min after endotracheal extubation, and the differences were statistically significant in favor of the experimental group (p<0.05. Conclusion: The study showed that the relaxation exercises after endotracheal extubation in open heart surgery patients was effective in improving vital signs and reducing anxiety level.

  5. [Successful double-lumen endotracheal tube exchange with a soft-tipped extra firm exchange catheter in a patient with severe subcutaneous emphysema].

    Science.gov (United States)

    Okamoto, Kaori; Komasawa, Nobuyasu; Ishio, Junichi; Nakano, Shoko; Tatsumi, Shinichi; Minami, Toshiaki

    2014-07-01

    We report a case of successful double-lumen endotracheal tube exchange with a soft-tipped extra firm exchange catheter in a patient with severe subcutaneous emphysema. A 70-year-old man underwent right lower lobectomy for primary lung cancer under general anesthesia. He developed pneumothorax on postoperative day (POD) 14, which led to subcutaneous emphysema. An emergent operation was performed on POD20 to close the pulmonary fistula under general anesthesia with a single-lumen endotracheal tube and bronchial blocker. Subcutaneous emphysema became worse and pharyngeal emphysema was also suspected; re-operation to close the pulmonary or bronchial fistula was planned. We decided to place a double-lumen tube to precisely detect the fistula. Under the guide of a Pentax-AWS Airwayscope, the single-lumen endotracheal tube was exchanged uneventfully to a 35 Fr double-lumen endotracheal tube with a 110 cm soft-tipped extra firm exchange catheter. The fistula was detected by a leak test and the operation was performed uneventfully, leading to improvement of subcutaneous emphysema.

  6. Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial.

    Science.gov (United States)

    Sitzwohl, Christian; Langheinrich, Angelika; Schober, Andreas; Krafft, Peter; Sessler, Daniel I; Herkner, Harald; Gonano, Christopher; Weinstabl, Christian; Kettner, Stephan C

    2010-11-09

    To determine which bedside method of detecting inadvertent endobronchial intubation in adults has the highest sensitivity and specificity. Prospective randomised blinded study. Department of anaesthesia in tertiary academic hospital. 160 consecutive patients (American Society of Anesthesiologists category I or II) aged 19-75 scheduled for elective gynaecological or urological surgery. Patients were randomly assigned to eight study groups. In four groups, an endotracheal tube was fibreoptically positioned 2.5-4.0 cm above the carina, whereas in the other four groups the tube was positioned in the right mainstem bronchus. The four groups differed in the bedside test used to verify the position of the endotracheal tube. To determine whether the tube was properly positioned in the trachea, in each patient first year residents and experienced anaesthetists were randomly assigned to independently perform bilateral auscultation of the chest (auscultation); observation and palpation of symmetrical chest movements (observation); estimation of the position of the tube by the insertion depth (tube depth); or a combination of all three (all three). Correct and incorrect judgments of endotracheal tube position. 160 patients underwent 320 observations by experienced and inexperienced anaesthetists. First year residents missed endobronchial intubation by auscultation in 55% of cases and performed significantly worse than experienced anaesthetists with this bedside test (odds ratio 10.0, 95% confidence interval 1.4 to 434). With a sensitivity of 88% (95% confidence interval 75% to 100%) and 100%, respectively, tube depth and the three tests combined were significantly more sensitive for detecting endobronchial intubation than auscultation (65%, 49% to 81%) or observation(43%, 25% to 60%) (Pauscultation to detect inadvertent endobronchial intubation. But even experienced physicians will benefit from inserting tubes to 20-21 cm in women and 22-23 cm in men, especially when high

  7. Advances in cost effective processing of titanium

    International Nuclear Information System (INIS)

    Nelson, O.E.

    1993-01-01

    Recently an industry expert pointed out that one of the greatest hindrances to the growth of titanium usage has been the low percentage of material usable in the final product. Due to the extensive processing, forming, and machining operations typically performed on titanium, yield losses are high. This is especially true in aerospace applications where most titanium is used. In engine components, the start to finish ratio, known as the buy to fly ratio, is often as high as 7 to 1. This can be illustrated by looking at the use of titanium in Pratt and Whitney engines. In the JT-8D-217 used on Boeing's 737-200, the titanium buyweight is 5,385 pounds, whereas the finished titanium, flyweight is just 758 pounds. This start to finish ratio is 7.1:1, giving titanium 17.0% of total engine weight. (orig.)

  8. Lactobacillusassisted synthesis of titanium nanoparticles

    Directory of Open Access Journals (Sweden)

    Jha Anal

    2007-01-01

    Full Text Available AbstractAn eco-friendlylactobacillussp. (microbe assisted synthesis of titanium nanoparticles is reported. The synthesis is performed at room temperature. X-ray and transmission electron microscopy analyses are performed to ascertain the formation of Ti nanoparticles. Individual nanoparticles as well as a number of aggregates almost spherical in shape having a size of 40–60 nm are found.

  9. On structural recrystallization in titanium

    International Nuclear Information System (INIS)

    Mirzaev, D.A.; Schastlivtsev, V.M.; Shtejnberg, M.M.; Ul'yanov, V.G.; AN SSSR, Sverdlovsk. Inst. Fiziki Metallov)

    1984-01-01

    The effect of preliminary superfast quenching on structural changes at inverse α→β transformation in titanium is studied. Cooling at rates more than 10 4 deg/s results in grain refining at succeeding annealing in β- and α- regions. The obtained effect is explained by additional phase transformation-induced hardening conditioned by decrease of the transformation point at superfast cooling

  10. Nanodispersed boriding of titanium alloy

    International Nuclear Information System (INIS)

    Kostyuk, K.O.; Kostyuk, V.O.

    2015-01-01

    The problem of improving the operational reliability of machines is becoming increasingly important due to the increased mechanical, thermal and other loads on the details. There are many surface hardening methods for machines parts which breakdown begins with surface corruption. The most promising methods are chemical-thermal treatment. The aim of this work is to study the impact of boriding on the structure and properties of titanium alloy. Materials and Methods: The material of this study is VT3-1 titanium alloy. The boriding were conducted using nanodispersed powder blend based on boric substances. It is established that boriding of paste compounds allows obtaining the surface hardness within 30 - 29 GPa and with declining to 27- 26 GPa in layer to the transition zone (with total thickness up to 110 μm) owing to changes of the layer phase composition where T 2 B, TiB, TiB 2 titanium borides are formed. The increasing of chemical-thermal treatment time from 15 minutes to 2 hours leads to thickening of the borated layer (30 - 110 μm) and transition zone (30 - 190 μm). Due to usage of nanodispersed boric powder, the boriding duration is decreasing in 2 - 3 times. This allows saving time and electric energy. The developed optimal mode of boriding the VT3-1 titanium alloy allows obtaining the required operational characteristics and to combine the saturation of the surface layer with atomic boron and hardening

  11. Ultrastructural analysis of metal particles released from stainless steel and titanium miniplate components in an animal model.

    Science.gov (United States)

    Matthew, I R; Frame, J W

    1998-01-01

    Low-vacuum scanning electron microscopy (Ivac SEM) was used to characterize the appearance of metal particles released from stressed and unstressed Champy miniplates placed in dogs and to study the relationship of the debris to the surrounding tissues. Under general endotracheal anesthesia, two Champy miniplates (titanium or stainless steel) were placed on the frontal bone in an animal model. One miniplate was bent to fit the curvature of the frontal bone (unstressed) and another miniplate of the same material was bent in a curve until the midpoint was raised 3 mm above the ends. The latter miniplate adapted to the skull curvature under tension during screw insertion (stressed). The miniplates and surrounding tissues were retrieved after intervals of 4, 12, and 24 weeks. Decalcified sections were prepared and examined by light microscopy and Ivac SEM. Under Ivac SEM examination, the titanium particles had a smooth, polygonal outline. Stainless steel particles were typically spherical, with numerous small projections on the surface. Most particles were 1 to 10 microns in diameter. The tissue response to the particles was variable; some particles were covered by fibrous connective tissue or enclosed by bone, and others were intracellular. The metal particles released from stressed or unstressed Champy miniplates were similar, and this was related to their source of origin and duration within the tissues. The tissue response to the particles appeared to depend on their location.

  12. Cell Attachment Following Instrumentation with Titanium and Plastic Instruments, Diode Laser, and Titanium Brush on Titanium, Titanium-Zirconium, and Zirconia Surfaces.

    Science.gov (United States)

    Lang, Melissa S; Cerutis, D Roselyn; Miyamoto, Takanari; Nunn, Martha E

    2016-01-01

    The aim of this study was to evaluate the surface characteristics and gingival fibroblast adhesion of disks composed of implant and abutment materials following brief and repeated instrumentation with instruments commonly used in procedures for implant maintenance, stage-two implant surgery, and periimplantitis treatment. One hundred twenty disks (40 titanium, 40 titaniumzirconium, 40 zirconia) were grouped into treatment categories of instrumentation by plastic curette, titanium curette, diode microlaser, rotary titanium brush, and no treatment. Twenty strokes were applied to half of the disks in the plastic and titanium curette treatment categories, while half of the disks received 100 strokes each to simulate implant maintenance occurring on a repetitive basis. Following analysis of the disks by optical laser profilometry, disks were cultured with human gingival fibroblasts. Cell counts were conducted from scanning electron microscopy (SEM) images. Differences in surface roughness across all instruments tested for zirconia disks were negligible, while both titanium disks and titaniumzirconium disks showed large differences in surface roughness across the spectrum of instruments tested. The rotary titanium brush and the titanium curette yielded the greatest overall mean surface roughness, while the plastic curette yielded the lowest mean surface roughness. The greatest mean cell counts for each disk type were as follows: titanium disks with plastic curettes, titanium-zirconium disks with titanium curettes, and zirconia disks with the diode microlaser. Repeated instrumentation did not result in cumulative changes in surface roughness of implant materials made of titanium, titanium-zirconium, or zirconia. Instrumentation with plastic implant curettes on titanium and zirconia surfaces appeared to be more favorable than titanium implant curettes in terms of gingival fibroblast attachment on these surfaces.

  13. Comparison of ProSeal laryngeal mask airway (PLMA with cuffed and uncuffed endotracheal tubes in infants

    Directory of Open Access Journals (Sweden)

    Eyyup Sabri Ozden

    2016-11-01

    Full Text Available We aimed to compare cuffed and uncuffed endotracheal tubes (ETTs with ProSealTM laryngeal mask airway (PLMA in terms of airway security and extubation, starting out from the hypothesis that PLMA will provide alternative airway safety to the endotracheal tubes, and that airway complications will be less observed. After obtaining approval from the local Ethics Committee and parental informed consent, 120 pediatric patients 1-24 months old, American Society of Anesthesiologists physical status I-II, requiring general anesthesia for elective lower abdominal surgery, were randomized into PLMA (Group P, n = 40, cuffed ETT (Group C, n = 40, and uncuffed ETT (Group UC, n = 40 groups. The number of intubation or PLMA insertion attempts was recorded. Each patient’s epigastrium was auscultated for gastric insufflation, leak volumes and air leak fractions (leak volume/inspiratory volume were recorded. Post-operative adverse events related to airway management were also followed up during the first post-operative hour. Demographic and surgical data were similar among the groups. There were significantly fewer airway manipulations in the Group P than in the other groups (p < 0.01, and leak volume and air leak fractions were greater in the Group UC than in the other two groups (p < 0.01. Laryngospasm was significantly lower in the Group P during extubation and within the first minute of post-extubation than in the other groups (p < 0.01. Based on this study, PLMA may be a good alternative to cuffed and uncuffed ETTs for airway management of infants due to the ease of manipulation and lower incidence of laryngospasm.

  14. Efficacy of Hi-Lo Evac Endotracheal Tube in Prevention of Ventilator-Associated Pneumonia in Mechanically Ventilated Poisoned Patients.

    Science.gov (United States)

    Ghoochani Khorasani, Ahmad; Shadnia, Shahin; Mashayekhian, Mohammad; Rahimi, Mitra; Aghabiklooei, Abbas

    2016-01-01

    Background. Ventilator-associated pneumonia (VAP) is the most common health care-associated infection. To prevent this complication, aspiration of subglottic secretions using Hi-Lo Evac endotracheal tube (Evac ETT) is a recommended intervention. However, there are some reports on Evac ETT dysfunction. We aimed to compare the incidence of VAP (per ventilated patients) in severely ill poisoned patients who were intubated using Evac ETT versus conventional endotracheal tubes (C-ETT) in our toxicology ICU. Materials and Methods. In this clinical randomized trial, 91 eligible patients with an expected duration of mechanical ventilation of more than 48 hours were recruited and randomly assigned into two groups: (1) subglottic secretion drainage (SSD) group who were intubated by Evac ETT (n = 43) and (2) control group who were intubated by C-ETT (n = 48). Results. Of the 91 eligible patients, 56 (61.5%) were male. VAP was detected in 24 of 43 (55.8%) patients in the case group and 23 of 48 (47.9%) patients in the control group (P = 0.45). The most frequently isolated microorganisms were S. aureus (54.10%) and Acinetobacter spp. (19.68%). The incidence of VAP and ICU length of stay were not significantly different between the two groups, but duration of intubation was statistically different and was longer in the SSD group. Mortality rate was less in SSD group but without a significant difference (P = 0.68). Conclusion. The SSD procedure was performed intermittently with one-hour intervals using 10 mL syringe. Subglottic secretion drainage does not significantly reduce the incidence of VAP in patients receiving MV. This strategy appears to be ineffective in preventing VAP among ICU patients.

  15. Efficacy of Hi-Lo Evac Endotracheal Tube in Prevention of Ventilator-Associated Pneumonia in Mechanically Ventilated Poisoned Patients

    Directory of Open Access Journals (Sweden)

    Ahmad Ghoochani Khorasani

    2016-01-01

    Full Text Available Background. Ventilator-associated pneumonia (VAP is the most common health care-associated infection. To prevent this complication, aspiration of subglottic secretions using Hi-Lo Evac endotracheal tube (Evac ETT is a recommended intervention. However, there are some reports on Evac ETT dysfunction. We aimed to compare the incidence of VAP (per ventilated patients in severely ill poisoned patients who were intubated using Evac ETT versus conventional endotracheal tubes (C-ETT in our toxicology ICU. Materials and Methods. In this clinical randomized trial, 91 eligible patients with an expected duration of mechanical ventilation of more than 48 hours were recruited and randomly assigned into two groups: (1 subglottic secretion drainage (SSD group who were intubated by Evac ETT (n=43 and (2 control group who were intubated by C-ETT (n=48. Results. Of the 91 eligible patients, 56 (61.5% were male. VAP was detected in 24 of 43 (55.8% patients in the case group and 23 of 48 (47.9% patients in the control group (P=0.45. The most frequently isolated microorganisms were S. aureus (54.10% and Acinetobacter spp. (19.68%. The incidence of VAP and ICU length of stay were not significantly different between the two groups, but duration of intubation was statistically different and was longer in the SSD group. Mortality rate was less in SSD group but without a significant difference (P=0.68. Conclusion. The SSD procedure was performed intermittently with one-hour intervals using 10 mL syringe. Subglottic secretion drainage does not significantly reduce the incidence of VAP in patients receiving MV. This strategy appears to be ineffective in preventing VAP among ICU patients.

  16. Is the Venner-PneuX Endotracheal Tube System A Cost-Effective Option For Post Cardiac Surgery Care?

    Science.gov (United States)

    Andronis, Lazaros; Oppong, Raymond A; Manga, Na'ngono; Senanayake, Eshan; Gopal, Shameer; Charman, Susan; Giri, Ramesh; Luckraz, Heyman

    2018-04-27

    Ventilator-associated pneumonia (VAP) is common and costly. In a recent randomized controlled trial, the Venner-PneuX (VPX) endotracheal tube system was found to be superior to standard endotracheal tubes (SET) in preventing VAP. However, VPX is considerably more expensive. We evaluated the costs and benefits of VPX to determine whether replacing SET with VPX is a cost-effective option for intensive care units. We developed a decision analytic model to compare intubation with VPX or SET for patients requiring mechanical ventilation post cardiac surgery. The model was populated with existing evidence on costs, effectiveness and quality of life. Cost-effectiveness and cost-utility analyses were conducted from an NHS hospital perspective. Uncertainty was assessed through deterministic and probabilistic sensitivity analyses. Compared to SET, VPX is associated with an expected cost saving of £738 per patient. VPX led to a small increase in quality-adjusted life years (QALYs), indicating that the device is overall less costly and more effective than SET. The probability of VPX being cost-effective at £30,000 per QALY is 97%. VPX would cease to be cost-effective if (i) it led to a risk reduction smaller than 0.02 compared to SET, (ii) the acquisition cost of VPX was as high as £890 or, (iii) the cost of treating a case of VAP was lower than £1,450. VPX resulted in improved outcomes and savings which far offset the cost of the device, suggesting that replacing SET with VPX is overall beneficial. Findings were robust to extreme values of key parameters. Copyright © 2018. Published by Elsevier Inc.

  17. Analysis of titanium content in titanium tetrachloride solution

    Science.gov (United States)

    Bi, Xiaoguo; Dong, Yingnan; Li, Shanshan; Guan, Duojiao; Wang, Jianyu; Tang, Meiling

    2018-03-01

    Strontium titanate, barium titan and lead titanate are new type of functional ceramic materials with good prospect, and titanium tetrachloride is a commonly in the production such products. Which excellent electrochemical performance of ferroelectric tempreature coefficient effect.In this article, three methods are used to calibrate the samples of titanium tetrachloride solution by back titration method, replacement titration method and gravimetric analysis method. The results show that the back titration method has many good points, for example, relatively simple operation, easy to judgment the titration end point, better accuracy and precision of analytical results, the relative standard deviation not less than 0.2%. So, it is the ideal of conventional analysis methods in the mass production.

  18. Single induction dose of etomidate versus other induction agents for endotracheal intubation in critically ill patients.

    Science.gov (United States)

    Bruder, Eric A; Ball, Ian M; Ridi, Stacy; Pickett, William; Hohl, Corinne

    2015-01-08

    trials in patients undergoing emergency endotracheal intubation for critical illness, including but not limited to trauma, stroke, myocardial infarction, arrhythmia, septic shock, hypovolaemic or haemorrhagic shock, and undifferentiated shock states. We included single (bolus) dose etomidate for emergency airway intervention compared to any other rapid-acting intravenous bolus single-dose induction agent. Refinement of our initial search results by title review, and then by abstract review was carried out by three review authors. Full-text review of potential studies was based on their adherence to our inclusion and exclusion criteria. This was decided by three independent review authors. We reported the decisions regarding inclusion and exclusion in accordance with the PRISMA statement.Electronic database searching yielded 1635 potential titles, and our grey literature search yielded an additional 31 potential titles. Duplicate titles were filtered leaving 1395 titles which underwent review of their titles and abstracts by three review authors. Sixty seven titles were judged to be relevant to our review, however only eight met our inclusion criteria and seven were included in our analysis. We included eight studies in the review and seven in the meta-analysis. Of those seven studies, only two were judged to be at low risk of bias. Overall, no strong evidence exists that etomidate increases mortality in critically ill patients when compared to other bolus dose induction agents (odds ratio (OR) 1.17; 95% confidence interval (CI) 0.86 to 1.60, 6 studies, 772 participants, moderate quality evidence). Due to a large number of participants lost to follow-up, we performed a post hoc sensitivity analysis. This gave a similar result (OR 1.15; 95% CI 0.86 to 1.53). There was evidence that the use of etomidate in critically ill patients was associated with a positive adrenocorticotropic hormone (ACTH) stimulation test, and this difference was more pronounced at between 4 to 6

  19. Continuous versus intermittent endotracheal cuff pressure control for the prevention of ventilator-associated respiratory infections in Vietnam: study protocol for a randomised controlled trial.

    Science.gov (United States)

    Dat, Vu Quoc; Geskus, Ronald B; Wolbers, Marcel; Loan, Huynh Thi; Yen, Lam Minh; Binh, Nguyen Thien; Chien, Le Thanh; Mai, Nguyen Thi Hoang; Phu, Nguyen Hoan; Lan, Nguyen Phu Huong; Hao, Nguyen Van; Long, Hoang Bao; Thuy, Tran Phuong; Kinh, Nguyen Van; Trung, Nguyen Vu; Phu, Vu Dinh; Cap, Nguyen Trung; Trinh, Dao Tuyet; Campbell, James; Kestelyn, Evelyne; Wertheim, Heiman F L; Wyncoll, Duncan; Thwaites, Guy Edward; van Doorn, H Rogier; Thwaites, C Louise; Nadjm, Behzad

    2018-04-04

    Ventilator-associated respiratory infection (VARI) comprises ventilator-associated pneumonia (VAP) and ventilator-associated tracheobronchitis (VAT). Although their diagnostic criteria vary, together these are the most common hospital-acquired infections in intensive care units (ICUs) worldwide, responsible for a large proportion of antibiotic use within ICUs. Evidence-based strategies for the prevention of VARI in resource-limited settings are lacking. Preventing the leakage of oropharyngeal secretions into the lung using continuous endotracheal cuff pressure control is a promising strategy. The aim of this study is to investigate the efficacy of automated, continuous endotracheal cuff pressure control in preventing the development of VARI and reducing antibiotic use in ICUs in Vietnam. This is an open-label randomised controlled multicentre trial. We will enrol 600 adult patients intubated for ≤ 24 h at the time of enrolment. Eligible patients will be stratified according to admission diagnosis (180 tetanus, 420 non-tetanus) and site and will be randomised in a 1:1 ratio to receive either (1) automated, continuous control of endotracheal cuff pressure or (2) intermittent measurement and control of endotracheal cuff pressure using a manual cuff pressure meter. The primary outcome is the occurrence of VARI, defined as either VAP or VAT during the ICU admission up to a maximum of 90 days after randomisation. Patients in both groups who are at risk for VARI will receive a standardised battery of investigations if their treating physician feels a new infection has occurred, the results of which will be used by an endpoint review committee, blinded to the allocated arm and independent of patient care, to determine the primary outcome. All enrolled patients will be followed for mortality and endotracheal tube cuff-related complications at 28 days and 90 days after randomisation. Other secondary outcomes include antibiotic use; days ventilated, in ICU and in hospital

  20. Titanium gettering in Doublet III

    International Nuclear Information System (INIS)

    de Grassie, J.S.; Callis, R.; Campbell, G.

    1980-08-01

    The application of mild titanium gettering in the Doublet III tokamak has led to a significant improvement in the obtainable operating regimes and discharge parameters for all of the many plasma cross-sectional shapes studied. With gettering, low-Z impurities and radiated power are greatly reduced. The maximum line averaged electron density has increased 50% (anti n/sub e max/ approx. 1 x 10 20 /m 3 ), corresponding to a Murakami coefficient of nearly 6

  1. Antibacterial and antiadherent properties of silver dioxide-coated brackets

    OpenAIRE

    Rizwan A Gilani; S M Laxmikanth; C S Ramachandra; Sangeeta L Prasad; Sushruth Shetty; S D Vasudevan

    2017-01-01

    Introduction: Enamel demineralization after fixed orthodontic treatment can occur in 50% of patients. Brackets play a significant role in enamel demineralization. Silver has already been prooved to have antibacterial properties. Hence the present study is conducted to assess the antiadherent and antibacterial properties of photocatalytic silver dioxide (AgO2) surface modified stainless steel orthodontic brackets against S. mutans. Materials and Methods: 80 stainless steel brackets of maxillar...

  2. Analogy and differences between aluminium and titanium electrowinning

    CSIR Research Space (South Africa)

    Van Vuuren, DS

    2006-09-01

    Full Text Available larger market. The authors have tested this route experimentally, but could not produce pure titanium. The failure of electrowinning pure, molten titanium has been interpreted in terms of the analogy and differences between aluminium and titanium...

  3. Research and Development on Titanium Alloys

    Science.gov (United States)

    1949-10-31

    information concerning the runs made * * In order to check the general operation of the train and furnace, a number of qualitative runs were made. These runs... General Technique. * . . * * . 109 The Analysis of Titanium . . . . ... ... 112 Notes and Comments, . . . .. . .. . . . 113 The Results from Vacuum...described in this report are as follows: 1. Arc ielting Titanium-Base Alloys. 2. Evaluation of Experimental Titanium-Base Alloys. 3. Investigation of

  4. Titanium metal obtention by fused salts electrolysis

    International Nuclear Information System (INIS)

    Perillo, P.M.; Ares, Osvaldo; Botbol, Jose.

    1989-01-01

    Potassium fluorotitanate dissolved in fused sodium chloride or potassium chloride may be electrolyzed under an inert gas atmosphere. Solid electrolysis products are formed on the cathode which contains titanium metal, sodium chloride, lower fluorotitanates and small quantities of alkali metal fluorotitanate. The extraction of titanium from the electrolysis products may be carried out by aqueous leaching (removal of chloride salts of alkali metals and a certain amount of fluorotitanates). Titanium metal obtained is relatively pure. (Author)

  5. Production of titanium from ilmenite: a review

    Energy Technology Data Exchange (ETDEWEB)

    Kohli, R.

    1981-12-01

    The general principles for beneficiation of titanium ores are reviewed and the specific processes used in individual units in various countries are discussed. This is followed by a critical evaluation of various current and potential reduction methods for the production of titanium metal from the processed concentrates. Finally, the report outlines a research program for the development of a commercially viable alternative method for the production of titanium metal.

  6. Strength and structure of nanocrystalline titanium

    International Nuclear Information System (INIS)

    Noskova, N.I.; Pereturina, I.A.; Elkina, O.A.; Stolyarov, V.V.

    2004-01-01

    Investigation results on strength and plasticity of nanocrystalline titanium VT-1 are presented. Specific features of plastic deformation on tension of this material specimens in an electron microscope column are studied in situ. It is shown that nanocrystalline titanium strength and plasticity at room temperature are dependent on the structure and nanograin size. It is revealed that deformation processes in nanocrystalline titanium are characterized by activation of deformation rotational modes and microtwinning [ru

  7. Cranioplasty with individual titanium implants

    Science.gov (United States)

    Mishinov, S.; Stupak, V.; Sadovoy, M.; Mamonova, E.; Koporushko, N.; Larkin, V.; Novokshonov, A.; Dolzhenko, D.; Panchenko, A.; Desyatykh, I.; Krasovsky, I.

    2017-09-01

    Cranioplasty is the second procedure in the history of neurosurgery after trepanation, and it is still relevant despite the development of civilization and progress in medicine. Each cranioplasty operation is unique because there are no two patients with identical defects of the skull bones. The development of Direct Metal Laser Sintering (DMLS) technique opened up the possibility of direct implant printing of titanium, a biocompatible metal used in medicine. This eliminates the need for producing any intermediate products to create the desired implant. We have produced 8 patient-specific titanium implants using this technique for patients who underwent different decompressive cranioectomies associated with bone tumors. Follow-up duration ranged from 6 to 12 months. We observed no implant-related reactions or complications. In all cases of reconstructive neurosurgery we achieved good clinical and aesthetic results. The analysis of the literature and our own experience in three-dimensional modeling, prototyping, and printing suggests that direct laser sintering of titanium is the optimal method to produce biocompatible surgical implants.

  8. Machinability evaluation of titanium alloys.

    Science.gov (United States)

    Kikuchi, Masafumi; Okuno, Osamu

    2004-03-01

    In the present study, the machinability of titanium, Ti-6Al-4V, Ti-6A1-7Nb, and free-cutting brass was evaluated using a milling machine. The metals were slotted with square end mills under four cutting conditions. The cutting force and the rotational speed of the spindle were measured. The cutting forces for Ti-6Al-4V and Ti-6Al-7Nb were higher and that for brass was lower than that for titanium. The rotational speed of the spindle was barely affected by cutting. The cross sections of the Ti-6Al-4V and Ti-6Al-7Nb chips were more clearly serrated than those of titanium, which is an indication of difficult-to-cut metals. There was no marked difference in the surface roughness of the cut surfaces among the metals. Cutting force and the appearance of the metal chips were found to be useful as indices of machinability and will aid in the development of new alloys for dental CAD/CAM and the selection of suitable machining conditions.

  9. Titanium Matrix Composite Pressure Vessel, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — For over 15 years, FMW Composite Systems has developed Metal Matrix Composite manufacturing methodologies for fabricating silicon-carbide-fiber-reinforced titanium...

  10. Appcelerator Titanium patterns and best practices

    CERN Document Server

    Pollentine, Boydlee

    2013-01-01

    The book takes a step-by-step approach to help you understand CommonJS and Titanium architecture patterns, with easy to follow samples and plenty of in-depth explanations If you're an existing Titanium developer or perhaps a new developer looking to start off your Titanium applications "the right way", then this book is for you. With easy to follow examples and a full step-by-step account of architecting a sample application using CommonJS and MVC, along with chapters on new features such as ACS, you'll be implementing enterprise grade Titanium solutions in no time. You should have some JavaSc

  11. Criterion of titanium aviation alloy application

    International Nuclear Information System (INIS)

    Stasyunas, O.P.

    1976-01-01

    The most significant statistic mechanical characteristics are presented of titanium as compared with those of aluminium and steel. Based on these data one can draw conclusions as to the advantages and disadvantages of titanium. High chemical activity and diffusivity of titanium place limitations on the use of its alloys. Despite the promising features of a needle-like structure, specifications still keep relying on a globular structure, which is explained by the easeiness of the production. Titanium is expensive, sometimes its cost may by a factor of 20 exceed that of other aviation materials

  12. Titanium. Properties, raw datum surface, physicochemical basis and fabrication technique

    International Nuclear Information System (INIS)

    Garmata, V.A.; Petrun'ko, A.N.; Galitskij, N.V.; Olesov, Yu.G.; Sandler, R.A.

    1983-01-01

    On the nowadays science and technology achievements the complex of titanium metallurgy problems comprising raw material base, physico-chemical basis and fabrication technique, properties and titanium usage fields is considered for the first time. A particular attention is given to raw material base, manufacturing titanium concentrates and titanium tetrachloride, metallothermal reduction, improvement of metal quality. Data on titanium properties are given, processes of titanium powder metallurgy, scrap and waste processing, problems of economics and complex raw material use are considered

  13. The vapour phase deposition of boron on titanium by the reaction between gaseous boron trichloride and titanium metal. Final report

    International Nuclear Information System (INIS)

    Cameron, D.J.; Shelton, R.A.J.

    1965-03-01

    The reaction, between boron trichloride vapour and titanium has been investigated in the temperature range 200 - 1350 deg. C. It has been found that an initial reaction leads to the formation of titanium tetrachloride and the deposition of boron on titanium, but that except for reactions between 900 and 1000 deg. C, the system is complicated by the formation of lower titanium chlorides due to secondary reactions between the titanium and titanium tetrachloride

  14. Dexmedetomidine as an adjunct to anesthetic induction to attenuate hemodynamic response to endotracheal intubation in patients undergoing fast-track CABG

    Directory of Open Access Journals (Sweden)

    Menda Ferdi

    2010-01-01

    Full Text Available During induction of general anesthesia hypertension and tachycardia caused by tracheal intubation may lead to cardiac ischemia and arrhythmias. In this prospective, randomized study, dexmedetomidine has been used to attenuate the hemodynamic response to endotracheal intubation with low dose fentanyl and etomidate in patients undergoing myocardial revascularization receiving beta blocker treatment. Thirty patients undergoing myocardial revascularization received in a double blind manner, either a saline placebo or a dexmedetomidine infusion (1 µg/kg before the anesthesia induction. Heart rate (HR and blood pressure (BP were monitored at baseline, after placebo or dexmedetomidine infusion, after induction of general anesthesia, one, three and five minutes after endotracheal intubation. In the dexmedetomidine (DEX group systolic (SAP, diastolic (DAP and mean arterial pressures (MAP were lower at all times in comparison to baseline values; in the placebo (PLA group SAP, DAP and MAP decreased after the induction of general anesthesia and five minutes after the intubation compared to baseline values. This decrease was not significantly different between the groups. After the induction of general anesthesia, the drop in HR was higher in DEX group compared to PLA group. One minute after endotracheal intubation, HR significantly increased in PLA group while, it decreased in the DEX group. The incidence of tachycardia, hypotension and bradycardia was not different between the groups. The incidence of hypertension requiring treatment was significantly greater in the PLA group. It is concluded that dexmedetomidine can safely be used to attenuate the hemodynamic response to endotracheal intubation in patients undergoing myocardial revascularization receiving beta blockers.

  15. Comparison of bolus and continuous infusion of esmolol on hemodynamic response to laryngoscopy, endotracheal intubation and sternotomy in coronary artery bypass graft

    Directory of Open Access Journals (Sweden)

    Esra Mercanooglu Efe

    2014-07-01

    Full Text Available BACKGROUND AND OBJECTIVE: The aim of this randomized, prospective and double blinded study is to investigate effects of different esmolol use on hemodynamic response of laryngoscopy, endotracheal intubation and sternotomy in coronary artery bypass graft surgery. METHODS: After approval of local ethics committee and patients' written informed consent, 45 patients were randomized into three groups equally. In Infusion Group; from 10 min before intubation up to 5th minute after sternotomy, 0.5 mg/kg/min esmolol infusion, in Bolus Group; 2 min before intubation and sternotomy 1.5 mg/kg esmolol IV bolus and in Control Group; %0.9 NaCl was administered. All demographic parameters were recorded. Heart rate and blood pressure were recorded before infusion up to anesthesia induction in every minute, during endotracheal intubation, every minute for 10 minutes after endotracheal intubation and before, during and after sternotomy at first and fifth minutes. RESULTS: While area under curve (AUC (SAP × time was being found more in Group B and C than Group I, AUC (SAP × T int and T st and AUC (SAP × T2 was found more in Group B and C than Group I (p < 0.05. Moreover AUC (HR × T st was found less in Group B than Group C but no significant difference was found between Group B and Group I. CONCLUSION: This study highlights that esmolol infusion is more effective than esmolol bolus administration on controlling systolic arterial pressure during endotracheal intubation and sternotomy in CABG surgery.

  16. A CLINICAL ASSESSMENT OF MACINTOSH BLADE, MILLER BLADE AND KING VISIONTM VIDEOLARYNGOSCOPE FOR LARYNGEAL EXPOSURE AND DIFFICULTY IN ENDOTRACHEAL INTUBATION

    Directory of Open Access Journals (Sweden)

    Apoorva Mahendera

    2016-03-01

    Full Text Available CONTEXT Previous studies suggest glottic view is better achieved with straight blades while tracheal intubation is easier with curved blades and videolaryngoscope is better than conventional laryngoscope. AIMS Comparison of conventional laryngoscope (Macintosh blade and Miller blade with channelled videolaryngoscope (King Vision TM with respect to laryngeal visualisation and difficulty in endotracheal intubation. SETTINGS AND DESIGN This prospective randomised comparative study was conducted at a tertiary care hospital (in ASA I and ASA II patients after approval from the Institutional Ethics Committee. METHODS We compared Macintosh, Miller, and the King VisionTM videolaryngoscope for glottic visualisation and ease of tracheal intubation. Patients undergoing elective surgeries under general anaesthesia requiring endotracheal intubation were randomly divided into three groups (N=180. After induction of anaesthesia, laryngoscopy was performed and trachea intubated. We recorded visualisation of glottis (Cormack-Lehane grade-CL, ease of intubation, number of attempts, need to change blade, and need for external laryngeal manipulation. STATISTICAL ANALYSIS Demographic data, Mandibular length, Mallampati classification were compared using ANOVA, Chi-square test, Kruskal-Wallis Test, where P value <0.005 is statically significant. RESULTS CL grade 1 was most often observed in King Vision -TM VL group (90% which is followed by Miller (28.33%, and Macintosh group (15%. We found intubation was to be easier (grade 1 with King Vision -TM VL group (73.33%, followed by Macintosh (38.33%, and Miller group (1.67%. External manipulation (BURP was needed more frequently in patients in Miller group (71.67%, followed by Macintosh (28.33% and in King Vision -TM VL group (6.67%. All (100% patients were intubated in the 1 st attempt with King Vision -TM VL group, followed by Macintosh group (90% and Miller group (58.33%. CONCLUSIONS In patients with normal airway

  17. Early antibiotic treatment for BAL-confirmed ventilator-associated pneumonia: a role for routine endotracheal aspirate cultures.

    Science.gov (United States)

    Michel, Fabrice; Franceschini, Bruno; Berger, Pierre; Arnal, Jean-Michel; Gainnier, Marc; Sainty, Jean-Marie; Papazian, Laurent

    2005-02-01

    To test whether routine quantitative cultures of endotracheal aspirates obtained before the onset of ventilator-associated pneumonia (VAP) could help to predict the causative microorganisms and to select early appropriate antimicrobial therapy before obtaining BAL culture results. Prospective observational study. French medical ICU. A total of 299 patients received mechanical ventilation for at least 48 h. Endotracheal aspiration (EA) was performed twice weekly in all mechanically ventilated patients. A diagnosis of VAP was made by BAL culture. Only the EA performed just before the suspicion of VAP (EA-pre) were evaluated. This strategy (ie, the EA-pre-based strategy) was compared with an antibiotic therapy that would have been prescribed if the recommendations of both the American Thoracic Society (ATS) and Trouillet et al (Am J Respir Crit Care Med 1998; 157:531-539) had been applied. VAP was diagnosed (by BAL culture) in 41 of the 75 patients in whom BAL was performed. Among the 41 BAL specimens that were positive for VAP, EA-pre had identified the same microorganisms (with the same antibiotic resistance patterns) in 34 cases (83%). In one case, EA-pre was not available at the time BAL was performed (a case of early-onset VAP), but the empiric antibiotic therapy was adequate. While EA-pre did not give the same results as the BAL culture, the antibiotic therapy based on the results of the EA-pre was adequate in four other cases. Finally, antibiotic therapy was delayed in only two cases. Antibiotic treatment was therefore adequate in 38 of the 40 assessable cases (95%). If the Trouillet-based strategy had been used, the antibiotic treatment would have been adequate in 34 of the 41 cases (83%; p = 0.15 [vs EA-pre strategy]). Based on the ATS classification, the antibiotic treatment would have been adequately prescribed in only 28 of the 41 cases (68%; p = 0.005 [vs EA-pre strategy]). Routine EA performed twice a week makes it possible to prescribe adequate

  18. Comparison of rocuronium at two different doses and succinylcholine for endotracheal intubation in adult patients for elective surgeries.

    Science.gov (United States)

    Chavan, S G; Gangadharan, S; Gopakumar, A K

    2016-01-01

    The effects of rocuronium at two different doses, that is, 0.6 mg/kg (2 × ED95) and 0.9 mg/kg (3 × ED95), were compared with succinylcholine (2 mg/kg) when used for endotracheal intubation in adult patients for elective surgeries under general anesthesia. Ninety patients were divided into three groups of 30 each. Groups A, B received injection rocuronium at 0.6 mg/kg, 0.9 mg/kg respectively and Group C received succinylcholine at 2 mg/kg. Onset of action of relaxant, intubation conditions, time taken to intubate and duration of action were compared. To compare the statistical difference in the age, weight, height of the study subjects, onset of action of relaxant, intubation conditions, time taken to intubate, and duration of action analysis of variance and unpaired t -test were used. The onset time was considerably shorter with rocuronium 0.9 mg/kg than 0.6 mg/kg. The onset time of rocuronium 0.9 mg/kg was found to be significantly longer than succinylcholine 2 mg/kg. Time taken to intubate was shortest with succinylcholine 2 mg/kg. The time taken to intubate with the rocuronium 0.9 mg/kg was found to be comparable to that of rocuronium 0.6 mg/kg. Intubation score of rocuronium 0.9 mg/kg was the best (17.75), which was comparable with succinylcholine. However, the intubation score obtained with rocuronium 0.6 mg/kg was inferior. Duration of action was shortest with succinylcholine. The duration of action is prolonged when the dose of rocuronium is increased from 0.6 to 0.9 mg/kg. Rapid sequence induction of anesthesia with propofol and fentanyl, succinylcholine allowed a more rapid endotracheal intubation sequence and created superior intubation conditions than rocuronium. However, the technique of using a large dose of rocuronium to achieve perfect conditions for tracheal intubation may have application whenever succinylcholine is relatively contraindicated.

  19. Low temperature study of nonstoichiometric titanium carbide

    International Nuclear Information System (INIS)

    Tashmetov, M.Yu.

    2005-05-01

    By low temperature neutron diffraction method was studied structure in nonstoichiometric titanium carbide from room temperature up to 12K. It is found of low temperature phase in titanium carbide- TiC 0.71 . It is established region and borders of this phase. It is determined change of unit cell parameter. (author)

  20. Casting of Titanium and its Alloys

    OpenAIRE

    R. L. Saha; K. T. Jacob

    1986-01-01

    Titaniuni and its alloys have many applications in aerospace, marine and other engineering industries. Titanium requires special melting techniques because of its high reactivity at elevated temperatures and needs special mould materials and methods for castings. This paper reviews the development of titanium casting technology.

  1. Appcelerator Titanium business application development cookbook

    CERN Document Server

    Bahrenberg, Benjamin

    2013-01-01

    Presented in easy to follow, step by step recipes, this guide is designed to lead you through the most important aspects of application design.Titanium developers who already have a basic knowledge of working with Appcelerator Titanium but want to further develop their knowledge for use with business applications

  2. Mineral resource of the month: titanium

    Science.gov (United States)

    Gambogi, Joseph

    2011-01-01

    Titanium is hip - at least when it comes to airplanes and jewelry. Known for its high strength-to weight ratio and its resistance to corrosion, titanium and its alloys can also be found in everything from knee replacements to eyeglass frames to baseball bats to fighter planes.

  3. Thermoexpanded graphite modification by titanium dioxide

    International Nuclear Information System (INIS)

    Semko, L.S.; Gorbik, P.P.; Chujko, O.O.; Kruchek, Ya.Yi.; Dzyubenko, L.S.; Orans'ka, O.Yi.

    2006-01-01

    A method of the synthesis of thermoexpanded graphite (TEG) powders coated by titanium dioxide is developed. The conversion of n-buthylorthotitanate into TiO 2 on the TEG surface is investigated. The optimal parameters of the synthesis and the structure of titanium dioxide clusters on the TEG surface are determined

  4. Titanium dioxide nanomaterials for photocatalysis

    International Nuclear Information System (INIS)

    Liu, Yan; Li, Zhe; Green, Michael; Just, Michael; Chen, Xiaobo; Li, Yang Yang

    2017-01-01

    Titanium dioxide (TiO 2 ) has been long regarded as one of the more promising photocatalysts to remove environmental pollution and to generate hydrogen from water under sunlight irradiation via photocatalysis. TiO 2 is environmentally benign and thus is considered a ‘green’ catalyst. In this review we present a short introduction to the physical and electronic properties of TiO 2 , its photocatalytic mechanisms, and some recent examples of various TiO 2 materials used for photocatalysis; these examples include 0, 1, 2, 3D, faceted, defected, composited, and hydrogenated TiO 2 materials. (topical review)

  5. Welding and Joining of Titanium Aluminides

    Science.gov (United States)

    Cao, Jian; Qi, Junlei; Song, Xiaoguo; Feng, Jicai

    2014-01-01

    Welding and joining of titanium aluminides is the key to making them more attractive in industrial fields. The purpose of this review is to provide a comprehensive overview of recent progress in welding and joining of titanium aluminides, as well as to introduce current research and application. The possible methods available for titanium aluminides involve brazing, diffusion bonding, fusion welding, friction welding and reactive joining. Of the numerous methods, solid-state diffusion bonding and vacuum brazing have been most heavily investigated for producing reliable joints. The current state of understanding and development of every welding and joining method for titanium aluminides is addressed respectively. The focus is on the fundamental understanding of microstructure characteristics and processing–microstructure–property relationships in the welding and joining of titanium aluminides to themselves and to other materials. PMID:28788113

  6. Welding and Joining of Titanium Aluminides

    Directory of Open Access Journals (Sweden)

    Jian Cao

    2014-06-01

    Full Text Available Welding and joining of titanium aluminides is the key to making them more attractive in industrial fields. The purpose of this review is to provide a comprehensive overview of recent progress in welding and joining of titanium aluminides, as well as to introduce current research and application. The possible methods available for titanium aluminides involve brazing, diffusion bonding, fusion welding, friction welding and reactive joining. Of the numerous methods, solid-state diffusion bonding and vacuum brazing have been most heavily investigated for producing reliable joints. The current state of understanding and development of every welding and joining method for titanium aluminides is addressed respectively. The focus is on the fundamental understanding of microstructure characteristics and processing–microstructure–property relationships in the welding and joining of titanium aluminides to themselves and to other materials.

  7. An application of the learning curve-cumulative summation test to evaluate training for endotracheal intubation in emergency medicine.

    Science.gov (United States)

    Je, Sangmo; Cho, Youngsuk; Choi, Hyuk Joong; Kang, Boseung; Lim, Taeho; Kang, Hyunggoo

    2015-04-01

    The learning curve-cumulative summation (LC-CUSUM) test allows for quantitative and individual assessments of the learning process. In this study, we evaluated the process of skill acquisition for performing endotracheal intubation (ETI) in three emergency medicine (EM) residents over a 2 year period in their first 2 years of their EM residency. We evaluated 342 ETI cases performed by three EM residents using the LC-CUSUM test according to their rate of success or failure of ETI. A 90% success rate (SR) was chosen to define adequate performance and an SR of 80% was considered inadequate. After the learning phase, the standard CUSUM test was applied to ensure that performance was maintained. The mean number of ETI cases required to reach the predefined level of performance was 74.7 (95% CI 62.0 to 87.3). CUSUM tests confirmed that performance was maintained after the learning phase. By using the LC-CUSUM test, we were able to quantitatively monitor the acquisition of the skill of ETI by EM residents. The LC-CUSUM could be useful for monitoring the learning process for the training of airway management in the practice of EM. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  8. A comparative study of efficacy of esmolol and fentanyl for pressure attenuation during laryngoscopy and endotracheal intubation

    Directory of Open Access Journals (Sweden)

    Shobhana Gupta

    2011-01-01

    Full Text Available Objective: To compare the effectiveness of single bolus dose of esmolol or fentanyl in attenuating the hemodynamic responses during laryngoscopy and endotracheal intubation. Methods: Ninety adult ASA I and ASA II patients were included in the study who underwent elective surgical procedures. Patients were divided into three groups. Group C (control receiving 10 ml normal saline, group E (esmolol receiving bolus dose of esmolol 2 mg/kg and group F (fentanyl receiving bolus dose of fentanyl 2 μg/kg intravenously slowly. Study drug was injected 3 min before induction of anesthesia. Heart rate, systemic arterial pressure and ECG were recorded as baseline and after administration of study drug at intubation and 15 min thereafter. Results: Reading of heart rate, blood pressure and rate pressure product were compared with baseline and among each group. The rise in heart rate was minimal in esmolol group and was highly significant. Also the rate pressure product at the time of intubation was minimal and was statistically significant rate 15 min thereafter in group E. Conclusion: Esmolol 2 mg/kg as a bolus done proved to be effective in attenuating rises in heart rate following laryngoscopy and intubation while the rise in blood pressure was suppressed but not abolished by bolus dose of esmolol.

  9. [The role of endotracheal aspirate culture in the diagnosis of ventilator-associated pneumonia: a meta analysis].

    Science.gov (United States)

    Wang, Fei; He, Bei

    2013-01-01

    To investigate the role of endotracheal aspirate (EA) culture in the diagnosis and antibiotic management in ventilator-associated pneumonia (VAP). We searched CNKI, Wanfang, PUBMED and EMBASE databases published from January 1990 to December 2011, to find relevant literatures on VAP microbiological diagnostic techniques including EA and bronchoalveolar lavage (BALF). The following key words were used: ventilator associated pneumonia, diagnosis and adult. Meta-analysis was performed and the sensitivity and specificity of EA on VAP diagnosis were calculated. Our literature search identified 1665 potential articles, 8 of which fulfilled our selection criteria including 561 patients with paired cultures. Using BALF quantitative culture as reference standard, the sensitivity and specificity of EA were 72% and 71%. When considering quantitative culture of EA only, the sensitivity and specificity improved to 90% and 65%, while the positive and the negative predictive values were 68% and 89% respectively. However, the sensitivity and specificity of semi-quantitative culture of EA were only 50% and 80%, with a positive predictive value of 77% and a negative predictive value of 58% respectively. EA culture had relatively poor sensitivity and specificity, although quantitative culture of EA only could improve the sensitivity. Initiating therapy on the basis of EA quantitative culture may still result in excessive antibiotic usage. Our data suggested that EA could provide some information for clinical decision but could not replace the role of BALF quantitative culture in VAP diagnosis.

  10. Endotracheal tube and laryngeal mask airway cuff volume changes with altitude: a rule of thumb for aeromedical transport.

    Science.gov (United States)

    Mann, Catherine; Parkinson, Neil; Bleetman, Anthony

    2007-03-01

    Helicopters and light (unpressurised) aircraft are used increasingly for the transport of ventilated patients. Most of these patients are ventilated through endotracheal tubes (ETTs), others through laryngeal mask airways (LMAs). The cuffs of both ETTs and LMAs inflate with increases in altitude as barometric pressure decreases (30 mbar/1000 feet). Tracheal mucosa perfusion becomes compromised at a pressure of approximately 30 cm H2O; critical perfusion pressure is 50 cm H2O. The change in dimensions of the inflated cuffs of a size 8 ETT and a size 5 LMA were measured with digital callipers at 1000 feet intervals in the unpressurised cabin of an Agusta 109 helicopter used by the Warwickshire and Northamptonshire Air Ambulance. A linear expansion in cuff dimensions as a function of altitude increase was identified. For ETTs, a formula for removal of air from the cuff with increasing altitude was calculated and is recommended for use in aeromedical transfers. This is 1/17x1.1 = 0.06 ml/1000 foot ascent/ml initial cuff inflation. The data for LMA cuff expansion failed to show significant correlation with altitude change. Further work is required to determine a similar rule of thumb for LMA cuff deflation.

  11. Ease of intubation: A randomized, double-blind study to compare two doses of rocuronium bromide for endotracheal intubation.

    Science.gov (United States)

    Shukla, Aparna; Misra, Shilpi

    2016-01-01

    Clinical need for a nondepolarizing agent with a rapid onset time and a brief duration of action has led to the development of rocuronium bromide. The aim of this study was to evaluate optimal dose of rocuronium bromide for intubation and to compare the onset time, duration of action, intubating conditions, and hemodynamic effects of two doses of rocuronium bromide. A prospective, randomized, double-blind study. All the patients were divided in a randomized, double-blind fashion into two groups of twenty patients each. Group I patients received rocuronium bromide 0.6 mg/kg intravenously and intubated at 60 s, Group II patients received rocuronium bromide 0.9 mg/kg and intubated at 60 s. The neuromuscular block was assessed using single twitch stimulation of 0.1 Hz at adductor pollicis muscle of hand at every 10 s. The results were compiled and analyzed statistically using Chi-square test for qualitative data and Student's t -test for quantitative data. Time of onset was significantly shorter ( P Rocuronium bromide 0.9 mg/kg is a safer alternative to rocuronium bromide 0.6 mg/kg for endotracheal intubation with shorter time of onset and better intubating conditions.

  12. EFFECT OF INTRACUFF MEDIA-ALKALINISED LIGNOCAINE, SALINE, AND AIR ON ENDOTRACHEAL TUBE INDUCED EMERGENCE PHENOMENA: A RANDOMIZED CONTROLLED STUDY

    Directory of Open Access Journals (Sweden)

    Indu S

    2016-07-01

    Full Text Available CONTEXT Emergence from general anaesthesia is associated with post extubation cough, hoarseness, sore throat, and dysphagia, which may affect the smoothness of extubation. Prophylactic interventions have been studied to reduce these tracheal morbidities with varying results. AIMS To compare the efficacy of air, alkalinised lignocaine and saline in maintaining intracuff pressure and reducing postoperative cough (PEC and sore throat (POST. SETTINGS AND DESIGN A randomised controlled study conducted in a teaching hospital. METHODS AND MATERIALS 105 patients scheduled for elective surgeries were randomly allocated into groups of 35 each. The endotracheal tube (ETT cuffs were inflated with air, alkalinised lignocaine, or saline. The intracuff pressure (ICP was initially set to 25-30 cm of H2O; measured every 30 minutes and before extubation; the minimum volume for occlusion (MOV noted. The incidence PEC and POST were monitored. STATISTICAL ANALYSIS Data analysed using Chi-square test, Fisher’s exact test; Bonferroni method allowed multiple comparisons. A p value <0.05 was considered significant. RESULTS Pre-lubricated ETT cuff inflation with liquid media maintained an acceptable ICP. Saline and alkalinised lignocaine were effective in reducing PEC and POST. Alkalinised lignocaine provided smoother extubation and fared better in the early postoperative period. CONCLUSIONS Pre-lubricated ETT cuffs with liquid media reduced PEC and POST. Alkalinised lignocaine showed better profile than saline. Optimum ICP reduces tracheal morbidity.

  13. Heat and moisture exchange capacity of the upper respiratory tract and the effect of tracheotomy breathing on endotracheal climate.

    Science.gov (United States)

    Scheenstra, Renske J; Muller, Sara H; Vincent, Andrew; Hilgers, Frans J M

    2011-01-01

    The aim of this study was to assess the heat and moisture exchange (HME) capacity of the upper respiratory tract and the effect of tracheotomy breathing on endotracheal climate in patients with head and neck cancer. We plotted the subglottic temperature and humidity measurements in 10 patients with head and neck cancer with a temporary precautionary tracheotomy during successive 10-minute periods of nose, mouth, and tracheotomy breathing in a randomized sequence. End-inspiratory temperatures of nose, mouth, and tracheotomy breathing were 31.1, 31.3, and 28.3°C, respectively. End-inspiratory humidity measurements of nose, mouth, and tracheotomy breathing were 29.3, 28.6, and 21.1 mgH₂O/L, respectively. There was a trend toward lower end-inspiratory humidity in patients with radiotherapy or with large surgery-induced oropharyngeal mucosal defects, whereas temperatures were similar. This study gives objective information about the HME capacity of the upper respiratory tract in patients with head and neck cancer with precautionary tracheotomy, and thus provides target values for HMEs for laryngectomized and tracheotomized patients. © 2010 Wiley Periodicals, Inc. Head Neck, 2011.

  14. The effect of laryngoscope handle size on possible endotracheal intubation success in university football, ice hockey, and soccer players.

    Science.gov (United States)

    Delaney, J Scott; Al-Kashmiri, Ammar; Baylis, Penny-Jane; Aljufaili, Mahmood; Correa, José A

    2012-07-01

    To assess the effectiveness of a standard long-handle laryngoscope and a short-handle laryngoscope on ease of possible intubation in football, ice hockey, and soccer players. Prospective crossover study. University Sport Medicine Clinic. Sixty-two university varsity football (62 males), 45 ice hockey (26 males and 19 females), and 39 soccer players (20 males, 19 females). Athletes were assessed for different airway and physical characteristics. Three different physicians then assessed the use of laryngoscopes of different handle sizes in supine athletes who were wearing protective equipment while in-line cervical spine immobilization was maintained. The ease of passage of a laryngoscope blade into the posterior oropharynx of a supine athlete was assessed using both a standard long-handle and a short-handle laryngoscope. Use of a short-handle laryngoscope was easier for all physicians in all sports as compared with a standard-sized laryngoscope. Passage of a laryngoscope blade into the posterior oropharynx of a supine athlete was easiest in soccer players and most difficult in football and ice hockey players for both sizes of laryngoscope. Interference from chest or shoulder pads was a common cause for difficulty in passing the laryngoscope blade into the posterior oropharynx for football and ice hockey players. In the rare instances that an endotracheal intubation is to be attempted on an unconscious athlete, a short-handle laryngoscope may provide the best chance for successful intubation.

  15. Titanium oxide fever; De titaniumoxidekoorts

    Energy Technology Data Exchange (ETDEWEB)

    De Jonge, D.; Visser, J. [Afdeling Luchtkwaliteit, GGD Amsterdam, Amsterdam (Netherlands)

    2012-02-15

    One measure to improve air quality is to apply photo-catalytic substances that capture NOx onto the road surface or onto baffle boards alongside the roads. The effect of titanium oxide containing clinkers with coating was discussed in the report 'Demonstration project of air-purifying pavement in Hengelo, The Netherlands' that was published in May 2011. This article examines the way in which the effectiveness of this study was determined. Can titanium oxide containing clinkers and coatings indeed capture NOx?. [Dutch] Een van de maatregelen om de luchtkwaliteit te verbeteren is het aanbrengen van fotokatalytische stoffen waarmee NOx kan worden afgevangen op bijvoorbeeld wegdek of op geluidsschermen langs wegen. Over het effect van titaniumoxidehoudende straatklinkers en hierop aangebrachte coatings verscheen in mei 2011 het rapport 'Demonstration project of air-purifying pavement in Hengelo, The Netherlands'. Dit artikel gaat over de manier waarop de effectiviteit in het hiervoor genoemde onderzoek is bepaald. Kunnen titaniumoxidehoudende klinkers en coatings inderdaad NOx afvangen?.

  16. Adsorption of hydrogen in titanium

    International Nuclear Information System (INIS)

    Martinez R, T.

    1995-01-01

    In this work the absorption of hydrogen in titanium plates using a constant volume system has been realized. The changes of temperature and pressure were used to monitor the progress of the absorption. A stainless steel vacuum chamber with volume of 4,333 cm 3 was used. A titanium sample of 45 x 5.4 x 0.3 cm was located in the center of the chamber. The sample was heated by an electrical source connected to the system. The sample was preconditioned with a vacuum-thermal treatment at 10 -6 mbar and 800 Centigrade degrees for several days. Absorption was observed at room temperature and also at higher temperatures. The room temperature absorption was in the pressure range of 1.0 x 10 3 to 2.5 x 10 3 mbar, and other absorptions were from 180 to 630 Centigrade degrees at 3.5 x 10 -1 to 1.3 x 10 3 mbar. It was found that the gas absorbed was function of the vacuum-thermal pre-conditioned treatment, pressure and temperature. When the first absorption was developed, additional absorptions were realized in short time. We measured the electrical resistivity of the sample in the experiments but we could not see important changes due to the absorption. (Author)

  17. Adhesive-Bonded Tab Attaches Thermocouples to Titanium

    Science.gov (United States)

    Cook, C. F.

    1982-01-01

    Mechanical strength of titanium-alloy structures that support thermocouples is preserved by first spotwelding thermocouples to titanium tabs and then attaching tabs to titanium with a thermosetting adhesive. In contrast to spot welding, a technique previously used for thermocouples, fatigue strength of the titanium is unaffected by adhesive bonding. Technique is also gentler than soldering or attaching thermocouples with a tap screw.

  18. Mechanical properties and fracture of titanium hydrides

    International Nuclear Information System (INIS)

    Koketsu, Hideyuki; Taniyama, Yoshihiro; Yonezu, Akio; Cho, Hideo; Ogawa, Takeshi; Takemoto, Mikio; Nakayama, Gen

    2006-01-01

    Titanium hydrides tend to suffer fracture when their thicknesses reach a critical thickness. Morphology and mechanical property of the hydrides are, however, not well known. The study aims to reveal the hydride morphology and fracture types of the hydrides. Chevron shaped plate hydrides were found to be produced on the surface of pure titanium (Grade 1) and Grade 7 titanium absorbing hydrogen. There were tree types of fracture of the hydrides, i.e., crack in hydride layer, exfoliation of the layer and shear-type fracture of the hydride plates, during the growth of the hydrides and deformation. We next estimated the true stress-strain curves of the hydrides on Grade 1 and 7 titanium using the dual Vickers indentation method, and the critical strain causing the Mode-I fine crack by indentation. Fracture strength and strain of the hydrides in Grade 1 titanium were estimated as 566 MPa and 4.5%, respectively. Those of the hydride in Grade 7 titanium were 498 MPa and 16%. Though the fracture strains estimated from the plastic instability of true stress-strain curves were approximately the half of those estimated by finite element method, the titanium hydrides were estimated to possess some extent of toughness or plastic deformation capability. (author)

  19. Electron beam melting of sponge titanium

    International Nuclear Information System (INIS)

    Kanayama, Hiroshi; Kusamichi, Tatsuhiko; Muraoka, Tetsuhiro; Onouye, Toshio; Nishimura, Takashi

    1991-01-01

    Fundamental investigations were done on electron beam (EB) melting of sponge titanium by using 80 kW EB melting furnace. Results obtained are as follows: (1) To increase the melting yield of titanium in EB melting of sponge titanium, it is important to recover splashed metal by installation of water-cooled copper wall around the hearth and to decrease evaporation loss of titanium by keeping the surface temperature of molten metal just above the melting temperature of titanium without local heating. (2) Specific power consumption of drip melting of pressed sponge titanium bar and hearth melting of sponge titanium are approximately 0.9 kWh/kg-Ti and 0.5-0.7 kWh/kg-Ti, respectively. (3) Ratios of the heat conducted to water-cooled mould in the drip melting and to water-cooled hearth in the hearth melting to the electron beam input power are 50-65% and 60-65%, respectively. (4) Surface defects of EB-melted ingots include rap which occurs when the EB output is excessively great, and transverse cracks when the EB output is excessively small. To prevent surface defects, the up-down withdrawal method is effective. (author)

  20. Ultrasonic effects on titanium tanning of leather.

    Science.gov (United States)

    Peng, Biyu; Shi, Bi; Sun, Danhong; Chen, Yaowen; Shelly, Dennis C

    2007-03-01

    The effects of ultrasound on titanium tanning of leather were investigated. Either 20 or 40 kHz ultrasound was applied to the titanium tanning of pigskins. Five different treatment conditions were carried out and the effects were examined, such as leather shrinkage temperature (T(s)), titanium content and titanium distribution in the leather. Overall heat loading was carefully controlled. Results showed that 20 kHz ultrasound effectively improves titanium agent penetration into the hide and increases the leather's shrinkage temperature. Doubling the frequency to 40 kHz produced negligible enhancements. An impressive 105.6 degrees C T(s) was achieved using 20 kHz ultrasound pretreatment of the tanning liquor followed by 20 kHz ultrasound in the tanning mixture (liquor plus pigskins) in a special salt-free medium. Finally, using a unique ultrasonic tanning drum with 26.5 kHz ultrasound, the T(s) reached a record level of 106.5 degrees C, a value not achieved in conventional (no ultrasound) titanium tanning. The ultrasonic effects on titanium tanning of leather are judged to make a superior mineral tanned leather.

  1. [The surface roughness analysis of the titanium casting founding by a new titanium casting investment material].

    Science.gov (United States)

    Liang, Qin-ye; Wu, Xia-yi; Lin, Xue-feng

    2012-04-01

    To investigate the surface roughness property of the titanium castings cast in a new investment for titanium casting. Six wax patterns (20 mm × 20 mm × 0.5 mm) were invested using two investments: three in a new titanium investment material and three in the control material (Rematitan Plus). Six titanium specimens were obtained by conventional casting. After casting, surface roughness of the specimens were evaluated with a surface profilometer. The surface roughness of the specimens cast in new titanium investment material was (1.72 ± 0.08) µm, which was much smaller than that from Rematitan Plus [(1.91 ± 0.15) µm, P cast using these two investment materials are both smooth enough to fulfill the demand of the titanium precision-casting for prosthodontic clinical use.

  2. Corrosion behaviour and galvanic coupling of titanium and welded titanium in LiBr solutions

    International Nuclear Information System (INIS)

    Blasco-Tamarit, E.; Igual-Munoz, A.; Garcia Anton, J.; Garcia-Garcia, D.

    2007-01-01

    Corrosion resistance and galvanic coupling of Grade 2 commercially pure titanium in its welded and non-welded condition were systematically analyzed in LiBr solutions. Galvanic corrosion was evaluated through two different methods: anodic polarization (according to the Mixed Potential Theory) and electrochemical noise (using a zero-resistance ammeter). Samples have been etched to study the microstructure. The action of lithium chromate as corrosion inhibitor has been evaluated. Titanium and welded titanium showed extremely low corrosion current densities and elevated pitting potential values (higher than 1 V). The results of both methods, anodic polarization and electrochemical noise, showed that the welded titanium was always the anodic element of the pair titanium-welded titanium, so that its corrosion resistance decreases due to the galvanic effect

  3. On the use of titanium hydride for powder injection moulding of titanium-based alloys

    International Nuclear Information System (INIS)

    Carrenoo-Morelli, E.; Bidaux, J.-E.

    2009-01-01

    Full text: Titanium and titanium-based alloys are excellent materials for a number of engineering applications because of their high strength, lightweight, good corrosion resistance, non magnetic characteristic and biocompatibility. The current processing steps are usually costly, and there is a growing demand for net-shape solutions for manufacturing parts of increasing complexity. Powder injection moulding is becoming a competitive alternative, thanks to the advances in production of good quality base-powders, binders and sintering facilities. Titanium hydride powders, have the attractiveness of being less reactive than fine titanium powders, easier to handle, and cheaper. This paper summarizes recent advances on PIM of titanium and titanium alloys from TiH2 powders, including shape-memory NiTi alloys. (author)

  4. Isothermal deformation of gamma titanium aluminide

    International Nuclear Information System (INIS)

    Srinivasan, R.; Singh, J.P.; Tuval, E.; Weiss, I.

    1996-01-01

    Gamma titanium aluminide has received considerable attention in recent years from the automotive industry as a potential material for making rotating and reciprocating components to produce a quieter and more efficient engine. The objectives of this study were to identify processing routes for the manufacture of automobile valves from gamma titanium aluminide. The issues considered were microstructure and composition of the material, and processing parameters such as deformation rates, temperatures, and total deformation. This paper examines isothermal deformation of gamma titanium aluminide in order to develop a processing window for this type of material

  5. Chemistry of titanium, zirconium and thorium picramates

    International Nuclear Information System (INIS)

    Srivastava, R.S.; Agrawal, S.P.; Bhargava, H.N.

    1976-01-01

    Picramates of titanium, zirconium and thorium are prepared by treating the aqueous sulphate, chloride and nitrate solutions with sodium picramate. Micro-analysis, colorimetry and spectrophotometry are used to establish the compositions (metal : ligand ratio) of these picramates as 1 : 2 (for titanium and zirconium) and 1 : 4 (for thorium). IR studies indicate H 2 N → Me coordination (where Me denotes the metal). A number of explosive properties of these picramates point to the fact that the zirconium picramate is thermally more stable than the picramates of titanium and thorium. (orig.) [de

  6. Titanium exposure and yellow nail syndrome

    Directory of Open Access Journals (Sweden)

    Ali Ataya

    2015-01-01

    Full Text Available Yellow nail syndrome is a rare disease of unclear etiology. We describe a patient who develops yellow nail syndrome, with primary nail and sinus manifestations, shortly after amalgam dental implants. A study of the patient's nail shedding showed elevated nail titanium levels. The patient had her dental implants removed and had complete resolution of her sinus symptoms with no change in her nail findings. Since the patient's nail findings did not resolve we do not believe titanium exposure is a cause of her yellow nail syndrome but perhaps a possible relationship exists between titanium exposure and yellow nail syndrome that requires further studies.

  7. Clinical bending of nickel titanium wires

    Directory of Open Access Journals (Sweden)

    Stephen Chain

    2015-01-01

    Full Text Available Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our inventory but also customized the wire according to the treatment.

  8. Current assisted superplastic forming of titanium alloy

    Directory of Open Access Journals (Sweden)

    Wang Guofeng

    2015-01-01

    Full Text Available Current assisted superplastic forming combines electric heating technology and superplastic forming technology, and can overcome some shortcomings of traditional superplastic forming effectively, such as slow heating rate, large energy loss, low production efficiency, etc. Since formability of titanium alloy at room temperature is poor, current assisted superplastic forming is suitable for titanium alloy. This paper mainly introduces the application of current assisted superplastic forming in the field of titanium alloy, including forming technology of double-hemisphere structure and bellows.

  9. Gentamicin-Eluting Titanium Dioxide Nanotubes Grown on the Ultrafine-Grained Titanium.

    Science.gov (United States)

    Nemati, Sima Hashemi; Hadjizadeh, Afra

    2017-08-01

    Titanium (Ti)-based materials is the most appropriate choices for the applications as orthopedic and dental implants. In this regard, ultrafine-grained (UFG) titanium with an enhanced mechanical properties and surface energy has attracted more attention. Titanium dioxide (TiO 2 ) nanotubes grown on the titanium could enhance bone bonding, cellular response and are good reservoirs for loading drugs and antibacterial agents. This article investigates gentamicin loading into and release from the TiO 2 nanotubes, grown on the UFG compared to coarse-grained (CG) titanium substrate surfaces. Equal Channel Angular Pressing (ECAP) was employed to produce the UFG structure titanium. TiO 2 nanotubes were grown by the anodizing technique on both UFG and CG titanium substrate surfaces. Scanning electron microscopy (SEM) imaging confirmed TiO 2 nanotube growth on the surface. The UV-vis spectroscopy analysis results show that the amount of gentamicin load-release in the anodized UFG titanium sample is higher than that of CG one which can be explained in terms of thicker TiO 2 nanotube arrays layer formed on UFG sample. Moreover, the anodized UFG titanium samples released the drug in a longer time than CG (1 day for the UFG titanium vs. 3 h for the CG one). Regarding wettability analysis, anodized UFG titanium sample showed more enhanced hydrophilicity than CG counterpart. Therefore, the significantly smaller grain size of pure titanium provided by the ECAP technique coupled with appropriate subsequent anodization treatment not only offers a good combination of biocompatibility and adequate mechanical properties but also it provides a delayed release condition for gentamicin.

  10. Leaching of Titanium and Silicon from Low-Grade Titanium Slag Using Hydrochloric Acid Leaching

    Science.gov (United States)

    Zhao, Longsheng; Wang, Lina; Qi, Tao; Chen, Desheng; Zhao, Hongxin; Liu, Yahui; Wang, Weijing

    2018-05-01

    Acid-leaching behaviors of the titanium slag obtained by selective reduction of vanadium-bearing titanomagnetite concentrates were investigated. It was found that the optimal leaching of titanium and silicon were 0.7% and 1.5%, respectively. The titanium and silicon in the titanium slag were firstly dissolved in the acidic solution to form TiO2+ and silica sol, and then rapidly reprecipitated, forming hydrochloric acid (HCl) leach residue. Most of the silicon presented in the HCl leach residue as floccules-like silica gel, while most of the titanium was distributed in the nano-sized rod-like clusters with crystallite refinement and intracrystalline defects, and, as such, 94.3% of the silicon was leached from the HCl leach residue by alkaline desilication, and 96.5% of the titanium in the titanium-rich material with some rutile structure was then digested by the concentrated sulfuric acid. This provides an alternative route for the comprehensive utilization of titanium and silicon in titanium slag.

  11. Synthesis of Titanium Oxycarbide from Titanium Slag by Methane-Containing Gas

    Science.gov (United States)

    Dang, Jie; Fatollahi-Fard, Farzin; Pistorius, Petrus Christiaan; Chou, Kuo-Chih

    2018-02-01

    In this study, reaction steps of a process for synthesis of titanium oxycarbide from titanium slag were demonstrated. This process involves the reduction of titanium slag by a methane-hydrogen-argon mixture at 1473 K (1200 °C) and the leaching of the reduced products by hydrofluoric acid near room temperature to remove the main impurity (Fe3Si). Some iron was formed by disproportionation of the main M3O5 phase before gaseous reduction started. Upon reduction, more iron formed first, followed by reduction of titanium dioxide to suboxides and eventually oxycarbide.

  12. Titanium disilicide formation by sputtering of titanium on heated silicon substrate

    Science.gov (United States)

    Tanielian, M.; Blackstone, S.

    1984-09-01

    We have sputter deposited titanium on bare silicon substrates at elevated temperatures. We find that at a substrate temperature of about 515 °C titanium silicide is formed due to the reaction of the titanium with the Si. The resistivity of the silicide is about 15 μΩ cm and it is not etchable in a selective titanium etch. This process can have applications in low-temperature, metal-oxide-semiconductor self-aligned silicide formation for very large scale integrated

  13. Titanium Aluminide Casting Technology Development

    Science.gov (United States)

    Bünck, Matthias; Stoyanov, Todor; Schievenbusch, Jan; Michels, Heiner; Gußfeld, Alexander

    2017-12-01

    Titanium aluminide alloys have been successfully introduced into civil aircraft engine technology in recent years, and a significant order volume increase is expected in the near future. Due to its beneficial buy-to-fly ratio, investment casting bears the highest potential for cost reduction of all competing production technologies for TiAl-LPTB. However, highest mechanical properties can be achieved by TiAl forging. In view of this, Access e.V. has developed technologies for the production of TiAl investment cast parts and TiAl die cast billets for forging purposes. While these parts meet the highest requirements, establishing series production and further optimizing resource and economic efficiency are present challenges. In order to meet these goals, Access has recently been certified according to aircraft standards, aiming at qualifying parts for production on technology readiness level 6. The present work gives an overview of the phases of development and certification.

  14. Erbium diffusion in titanium dioxide

    Directory of Open Access Journals (Sweden)

    Louise Basse

    2017-04-01

    Full Text Available The diffusivity of erbium in the anatase phase of titanium dioxide (TiO2 has been studied for various temperatures ranging from 800 °C to 1, 000 °C. Samples of TiO2, with a 10 nm thick buried layer containing 0.5 at% erbium, were fabricated by radio-frequency magnetron sputtering and subsequently heat treated. The erbium concentration profiles were measured by secondary ion mass spectrometry, allowing for determination of the temperature-dependent diffusion coefficients. These were found to follow an Arrhenius law with an activation energy of ( 2.1 ± 0.2 eV. X-ray diffraction revealed that the TiO2 films consisted of polycrystalline grains of size ≈ 100 nm.

  15. Auscultation versus Point-of-care Ultrasound to Determine Endotracheal versus Bronchial Intubation: A Diagnostic Accuracy Study.

    Science.gov (United States)

    Ramsingh, Davinder; Frank, Ethan; Haughton, Robert; Schilling, John; Gimenez, Kimberly M; Banh, Esther; Rinehart, Joseph; Cannesson, Maxime

    2016-05-01

    Unrecognized malposition of the endotracheal tube (ETT) can lead to severe complications in patients under general anesthesia. The focus of this double-blinded randomized study was to assess the accuracy of point-of-care ultrasound in verifying the correct position of the ETT and to compare it with the accuracy of auscultation. Forty-two adult patients requiring general anesthesia with ETT were consented. Patients were randomized to right main bronchus, left main bronchus, or tracheal intubation. After randomization, the ETT was placed via fiber-optic visualization. Next, the location of the ETT was assessed using auscultation by a separate blinded anesthesiologist, followed by an ultrasound performed by a third blinded anesthesiologist. Ultrasound examination included assessment of tracheal dilation via cuff inflation with air and evaluation of pleural lung sliding. Statistical analysis included sensitivity, specificity, positive predictive value, negative predictive value, and interobserver agreement for the ultrasound examination (95% CI). In differentiating tracheal versus bronchial intubations, auscultation showed a sensitivity of 66% (0.39 to 0.87) and a specificity of 59% (0.39 to 0.77), whereas ultrasound showed a sensitivity of 93% (0.66 to 0.99) and specificity of 96% (0.79 to 1). Identification of tracheal versus bronchial intubation was 62% (26 of 42) in the auscultation group and 95% (40 of 42) in the ultrasound group (P = 0.0005) (CI for difference, 0.15 to 0.52), and the McNemar comparison showed statistically significant improvement with ultrasound (P auscultation in determining the location of ETT.

  16. Colorimetric end-tidal CO2 detector for verification of endotracheal tube placement in out-of-hospital cardiac arrest.

    Science.gov (United States)

    Hayden, S R; Sciammarella, J; Viccellio, P; Thode, H; Delagi, R

    1995-06-01

    To evaluate the ability of a disposable, colorimetric end-tidal CO2 detector to verify proper endotracheal (ET) tube placement in out-of-hospital cardiac arrest, and to correlate semiquantitative CO2 measurements with the rate of return of spontaneous circulation (ROSC). Prospective, observational study using a convenience sample of intubated out-of-hospital cardiac arrest patients. A disposable, colorimetric end-tidal CO2 detector was attached to the ET tube after intubation. In the absence of a colorimetric change, the paramedics reassessed the tube placement and could reintubate the patient. Tube placement was verified at the hospital. Paramedics were instructed to contact the base station and report the colorimetric change upon hospital arrival. ROSC was defined as restoration of a self-sustaining pulse until hospital arrival. Between December 1990 and May 1993, ET tubes were placed in 566 victims of out-of-hospital cardiac arrest. 541 of the 566 intubations (95.6%) were associated with a color change. In one case with a color change and out-of-hospital clinical evidence of proper tube placement, the tube was determined to be in the esophagus at the hospital. Correct placement of the remaining 565 of 566 (99.8%) tubes was verified. Of the 566 patients who had a colorimetric change, 91 (16%) had ROSC vs one of 25 (4%) patients who did not have a color change. In one subgroup (n = 179), the degree of color change was highly associated with ROSC (p = 0.004). A disposable, colorimetric end-tidal CO2 detector appears reliable in verifying proper ET tube placement in victims of out-of-hospital cardiac arrest. The degree of color change correlates with the probability of ROSC.

  17. Low flow anesthesia: Efficacy and outcome of laryngeal mask airway versus pressure-optimized cuffed-endotracheal tube

    Directory of Open Access Journals (Sweden)

    El-Seify Zeinab

    2010-01-01

    Full Text Available Background: Low flow anesthesia can lead to reduction of anesthetic gas and vapor consumption. Laryngeal mask airway (LMA has proved to be an effective and safe airway device. The aim of this study is to assess the feasibility of laryngeal mask airway during controlled ventilation using low fresh gas flow (1.0 L/min as compared to endotracheal tube (ETT. Patients and Methods : Fifty nine non-smoking adult patients; ASA I or II, being scheduled for elective surgical procedures, with an expected duration of anesthesia 60 minutes or more, were randomly allocated into two groups - Group I (29 patients had been ventilated using LMA size 4 for females and 5 for males respectively; and Group II (30 patients were intubated using ETT. After 10 minutes of high fresh gas flow, the flow was reduced to 1 L/min. Patients were monitored for airway leakage, end-tidal CO 2 (ETCO 2 , inspiratory and expiratory isoflurane and nitrous oxide fraction concentrations, and postoperative airway-related complications Results : Two patients in the LMA-group developed initial airway leakage (6.9% versus no patient in ETT-group. Cough and sore throat were significantly higher in ETT patients. There were no evidences of differences between both groups regarding ETCO 2 , uptake of gases, nor difficulty in swallowing. Conclusion : The laryngeal mask airway proved to be effective and safe in establishing an airtight seal during controlled ventilation under low fresh gas flow of 1 L/min, inducing less coughing and sore throat during the immediate postoperative period than did the ETT, with continuous measurement and readjustment of the tube cuff pressure.

  18. Carbon nanotube-based coatings on titanium

    Indian Academy of Sciences (India)

    Administrator

    mon method is the deposition of bioactive ceramic mate- rials on the metal ... tion of nanoparticle layer, including carbon nanoparti- ... Coatings made of CNTs provide implants with .... reaches composite of CNT built into titanium oxide formed.

  19. Titanium Brazing for Structures and Survivability

    National Research Council Canada - National Science Library

    Doherty, Kevin J; Tice, Jason R; Szewczyk, Steven T; Glide, Gary A

    2007-01-01

    .... While welding is the typical joining method for titanium, vacuum brazing is an option in areas that are difficult to access for welding as well as areas near other nonmetallic materials, such as ceramics...

  20. Titanium application to power plant condensers

    International Nuclear Information System (INIS)

    Itoh, H.

    1987-01-01

    Recently, the growth of operating performance and construction plan of titanium-tubed condensers in thermal and unclear power plants has been very impressive. High-quality, thinner welded titanium tubes used for cooling tubes, matching design specifications of condensers, have been stably supplied through mass production. It now can be said that various technical problems for titanium-tubed condensers have been solved, but data on operating performance in large-scale commercial plants are still scarce, and site-by-site information needs be exchanged more frequently and on a larger scale. Projects to replace existing condenser cooling tubes with those of corrosion-resistant titanium have been actively furthered, with the only remaining barrier to full employment being cost effectiveness. It is hoped that condenser and tube manufacturers will conduct more joint value analyses

  1. Stress corrosion cracking of titanium alloys

    Science.gov (United States)

    May, R. C.; Beck, F. H.; Fontana, M. G.

    1971-01-01

    Experiments were conducted to study (1) the basic electrochemical behavior of titanium in acid chloride solutions and (2) the response of the metal to dynamic straining in the same evironment. The aim of this group of experiments was to simulate, as nearly as possible, the actual conditions which exist at the tip of a crack. One of the foremost theories proposed to explain the propagation of stress corrosion cracks is a hydrogen embrittlement theory involving the precipitation of embrittling titanium hydrides inside the metal near the crack tip. An initial survey of the basic electrochemical literature indicated that surface hydrides play a critical role in the electrochemistry of titanium in acid solutions. A comprehensive analysis of the effect of surface films, particularly hydrides, on the electrochemical behavior of titanium in these solution is presented.

  2. Titanium Heat Pipe Thermal Plane, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the Phase II program is to complete the development of the titanium heat pipe thermal plane and establish all necessary steps for production of this...

  3. Titanium Nanocomposite: Lightweight Multifunction Structural Material

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to research and develop lightweight metal matrix nanocomposites (MMnC) using a Titanium (Ti) metal matrix. Ti MMnC will crosscut the advancement of both...

  4. Corrosion resistance of titanium alloys for dentistry

    International Nuclear Information System (INIS)

    Laskawiec, J.; Michalik, R.

    2001-01-01

    Titanium and its alloys belong to biomaterials which the application scope in medicine increases. Some properties of the alloys, such as high mechanical strength, low density, low Young's modulus, high corrosion resistance and good biotolerance decide about it. The main areas of the application of titanium and its alloys are: orthopedics and traumatology, cardiosurgery, faciomaxillary surgery and dentistry. The results of investigations concerning the corrosion resistance of the technical titanium and Ti6Al14V alloy and comparatively a cobalt alloy of the Vitallium type in the artificial saliva is presented in the work. Significantly better corrosion resistance of titanium and the Ti6Al14V than the Co-Cr-Mo alloy was found. (author)

  5. Interfacial reactions between titanium and borate glass

    Energy Technology Data Exchange (ETDEWEB)

    Brow, R.K. [Sandia National Labs., Albuquerque, NM (United States); Saha, S.K.; Goldstein, J.I. [Lehigh Univ., Bethlehem, PA (United States). Dept. of Materials Science

    1992-12-31

    Interfacial reactions between melts of several borate glasses and titanium have been investigated by analytical scanning electron microscopy (SEM) and x-ray photoelectron spectroscopy (XPS). A thin titanium boride interfacial layer is detected by XPS after short (30 minutes) thermal treatments. ASEM analyses after longer thermal treatments (8--120 hours) reveal boron-rich interfacial layers and boride precipitates in the Ti side of the interface.

  6. Lubrication for hot working of titanium alloys

    International Nuclear Information System (INIS)

    Gotlib, B.M.

    1980-01-01

    The isothermal lubrication of the following composition is suggested, wt. %: aluminium powder 4-6, iron scale 15-25, vitreous enamel up to 100. The lubricant improves forming and decreases the danger of the metal fracture when titanium alloys working. It is advisable to use the suggested lubrication when stamping thin-walled products of titanium alloys at the blank temperature from 700 to 1000 deg C [ru

  7. Friction Welding of Titanium and Carbon Steel

    OpenAIRE

    Atsushi, HASUI; Yoichi, KIRA; Faculty of Science and Technology, Keio University; Ishikawajima-Harima Heavy Industries, Co., Ltd.

    1985-01-01

    Titanium-steel is a combination of dissimilar materials, which are difficult to weld in general, owing to inevitable formation of brittle intermetallic compounds. A prominent feature of friction welding process is ability to weld dissimilar materials in many kinds of combinations. This report deals with friction weldabilily of pure titanium and S25C steel, which are 12 mm in diameter. Main results are summarized as follows; (1) Suitable welding conditions to obtain a sound weld, which has a j...

  8. A Multicenter, Randomized Trial of Ramped Position vs Sniffing Position During Endotracheal Intubation of Critically Ill Adults.

    Science.gov (United States)

    Semler, Matthew W; Janz, David R; Russell, Derek W; Casey, Jonathan D; Lentz, Robert J; Zouk, Aline N; deBoisblanc, Bennett P; Santanilla, Jairo I; Khan, Yasin A; Joffe, Aaron M; Stigler, William S; Rice, Todd W

    2017-10-01

    Hypoxemia is the most common complication during endotracheal intubation of critically ill adults. Intubation in the ramped position has been hypothesized to prevent hypoxemia by increasing functional residual capacity and decreasing the duration of intubation, but has never been studied outside of the operating room. Multicenter, randomized trial comparing the ramped position (head of the bed elevated to 25°) with the sniffing position (torso supine, neck flexed, and head extended) among 260 adults undergoing endotracheal intubation by pulmonary and critical care medicine fellows in four ICUs between July 22, 2015, and July 19, 2016. The primary outcome was lowest arterial oxygen saturation between induction and 2 minutes after intubation. Secondary outcomes included Cormack-Lehane grade of glottic view, difficulty of intubation, and number of laryngoscopy attempts. The median lowest arterial oxygen saturation was 93% (interquartile range [IQR], 84%-99%) with the ramped position vs 92% (IQR, 79%-98%) with the sniffing position (P = .27). The ramped position appeared to increase the incidence of grade III or IV view (25.4% vs 11.5%, P = .01), increase the incidence of difficult intubation (12.3% vs 4.6%, P = .04), and decrease the rate of intubation on the first attempt (76.2% vs 85.4%, P = .02), respectively. In this multicenter trial, the ramped position did not improve oxygenation during endotracheal intubation of critically ill adults compared with the sniffing position. The ramped position may worsen glottic view and increase the number of laryngoscopy attempts required for successful intubation. ClinicalTrials.gov; No.: NCT02497729; URL: www.clinicaltrials.gov. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  9. Lactam inhibiting Streptococcus mutans growth on titanium

    Energy Technology Data Exchange (ETDEWEB)

    Xavier, J.G.; Geremias, T.C.; Montero, J.F.D. [Center for Research on Dental Implants (CEPID), School of Dentistry (ODT), Federal University of Santa Catarina - UFSC, Florianópolis/SC, 88040-900 (Brazil); Vahey, B.R. [Herman Ostrow School of Dentistry of USC, 925 W 34 St, Los Angeles, CA 90089 (United States); Benfatti, C.A.M.; Souza, J.C.M.; Magini, R.S. [Center for Research on Dental Implants (CEPID), School of Dentistry (ODT), Federal University of Santa Catarina - UFSC, Florianópolis/SC, 88040-900 (Brazil); Pimenta, A.L., E-mail: andrea@intelab.ufsc.br [Department of Biologia, ERRMECe, Université de Cergy Pontoise, 2, Av. Adolphe Chauvin 95302 Cergy, Pontoise (France); Integrated Laboratories Technologies (InteLab), Dept. Chemical and Food Engineering (EQA), Federal University of Santa Catarina - UFSC, Florianópolis/SC, 88040-970 (Brazil)

    2016-11-01

    The aim of this work was to analyze the activity of novel synthetic lactams on preventing biofilm formation on titanium surfaces. Titanium (Ti6Al4V) samples were exposed to Streptococcus mutans cultures in the presence or absence of a synthetic lactam. After 48 h incubation, planktonic growth was determined by spectrophotometry. Biofilm was evaluated by crystal violet staining and colony forming units (CFU·ml{sup −1}), followed by scanning electron microscopy (SEM). Results showed that the average of adhered viable cells was approximately 1.5 × 10{sup 2} CFU/ml in the presence of lactam and 4 × 10{sup 2} CFU/ml in its absence. This novel compound was considerable active in reducing biofilm formation over titanium surfaces, indicating its potential for the development of antimicrobial drugs targeting the inhibition of the initial stages of bacterial biofilms on dental implants abutments. - Highlights: • A novel synthetic compound is tested on preventing biofilm formation on titanium surfaces • Biofilm inhibition has been achieved on titanium surfaces containing the novel compound. • Planktonic growth of S. mutans was not affected by the presence of lactams on titanium.

  10. Lactam inhibiting Streptococcus mutans growth on titanium

    International Nuclear Information System (INIS)

    Xavier, J.G.; Geremias, T.C.; Montero, J.F.D.; Vahey, B.R.; Benfatti, C.A.M.; Souza, J.C.M.; Magini, R.S.; Pimenta, A.L.

    2016-01-01

    The aim of this work was to analyze the activity of novel synthetic lactams on preventing biofilm formation on titanium surfaces. Titanium (Ti6Al4V) samples were exposed to Streptococcus mutans cultures in the presence or absence of a synthetic lactam. After 48 h incubation, planktonic growth was determined by spectrophotometry. Biofilm was evaluated by crystal violet staining and colony forming units (CFU·ml −1 ), followed by scanning electron microscopy (SEM). Results showed that the average of adhered viable cells was approximately 1.5 × 10 2 CFU/ml in the presence of lactam and 4 × 10 2 CFU/ml in its absence. This novel compound was considerable active in reducing biofilm formation over titanium surfaces, indicating its potential for the development of antimicrobial drugs targeting the inhibition of the initial stages of bacterial biofilms on dental implants abutments. - Highlights: • A novel synthetic compound is tested on preventing biofilm formation on titanium surfaces • Biofilm inhibition has been achieved on titanium surfaces containing the novel compound. • Planktonic growth of S. mutans was not affected by the presence of lactams on titanium.

  11. Longitudinal effects of single-dose simulation education with structured debriefing and verbal feedback on endotracheal suctioning knowledge and skills: A randomized controlled trial.

    Science.gov (United States)

    Jansson, Miia M; Syrjälä, Hannu P; Ohtonen, Pasi P; Meriläinen, Merja H; Kyngäs, Helvi A; Ala-Kokko, Tero I

    2017-01-01

    We evaluated the longitudinal effects of single-dose simulation education with structured debriefing and verbal feedback on critical care nurses' endotracheal suctioning knowledge and skills. To do this we used an experimental design without other competing intervention. Twenty-four months after simulation education, no significant time and group differences or time × group interactions were identified between the study groups. The need for regularly repeated educational interventions with audiovisual or individualized performance feedback and repeated bedside demonstrations is evident. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  12. The effect of titanium surface treatment on the interfacial strength of titanium – Thermoplastic composite joints

    NARCIS (Netherlands)

    Su, Yibo; de Rooij, Matthijn; Grouve, Wouter; Akkerman, Remko

    2017-01-01

    Co-consolidated titanium – carbon fibre reinforced thermoplastic composite hybrid joints show potential for application in aerospace structures. The strength of the interface between the titanium and the thermoplastic composite is crucial for the strength of the entire hybrid joint. Application of a

  13. Artefacts in multimodal imaging of titanium, zirconium and binary titanium-zirconium alloy dental implants: an in vitro study.

    Science.gov (United States)

    Smeets, Ralf; Schöllchen, Maximilian; Gauer, Tobias; Aarabi, Ghazal; Assaf, Alexandre T; Rendenbach, Carsten; Beck-Broichsitter, Benedicta; Semmusch, Jan; Sedlacik, Jan; Heiland, Max; Fiehler, Jens; Siemonsen, Susanne

    2017-02-01

    To analyze and evaluate imaging artefacts induced by zirconium, titanium and titanium-zirconium alloy dental implants. Zirconium, titanium and titanium-zirconium alloy implants were embedded in gelatin and MRI, CT and CBCT were performed. Standard protocols were used for each modality. For MRI, line-distance profiles were plotted to quantify the accuracy of size determination. For CT and CBCT, six shells surrounding the implant were defined every 0.5 cm from the implant surface and histogram parameters were determined for each shell. While titanium and titanium-zirconium alloy induced extensive signal voids in MRI owing to strong susceptibility, zirconium implants were clearly definable with only minor distortion artefacts. For titanium and titanium-zirconium alloy, the MR signal was attenuated up to 14.1 mm from the implant. In CT, titanium and titanium-zirconium alloy resulted in less streak artefacts in comparison with zirconium. In CBCT, titanium-zirconium alloy induced more severe artefacts than zirconium and titanium. MRI allows for an excellent image contrast and limited artefacts in patients with zirconium implants. CT and CBCT examinations are less affected by artefacts from titanium and titanium-zirconium alloy implants compared with MRI. The knowledge about differences of artefacts through different implant materials and image modalities might help support clinical decisions for the choice of implant material or imaging device in the clinical setting.

  14. Development and Evaluation of Titanium Spacesuit Bearings

    Science.gov (United States)

    Rhodes, Richard; Battisti, Brian; Ytuarte, Raymond, Jr.; Schultz, Bradley

    2016-01-01

    The Z-2 Prototype Planetary Extravehicular Space Suit Assembly is a continuation of NASA's Z-series of spacesuits, designed with the intent of meeting a wide variety of exploration mission objectives, including human exploration of the Martian surface. Incorporating titanium bearings into the Z-series space suit architecture allows us to reduce mass by an estimated 23 lbs per suit system compared to the previously used stainless steel bearing race designs, without compromising suit functionality. There are two obstacles to overcome when using titanium for a bearing race- 1) titanium is flammable when exposed to the oxygen wetted environment inside the space suit and 2) titanium's poor wear properties are often challenging to overcome in tribology applications. In order to evaluate the ignitability of a titanium space suit bearing, a series of tests were conducted at White Sands Test Facility (WSTF) that introduced the bearings to an extreme test profile, with multiple failures imbedded into the test bearings. The testing showed no signs of ignition in the most extreme test cases; however, substantial wear of the bearing races was observed. In order to design a bearing that can last an entire exploration mission (approx. 3 years), design parameters for maximum contact stress need to be identified. To identify these design parameters, bearing test rigs were developed that allow for the quick evaluation of various bearing ball loads, ball diameters, lubricants, and surface treatments. This test data will allow designers to minimize the titanium bearing mass for a specific material and lubricant combination and design around a cycle life requirement for an exploration mission. This paper reviews the current research and testing that has been performed on titanium bearing races to evaluate the use of such materials in an enriched oxygen environment and to optimize the bearing assembly mass and tribological properties to accommodate for the high bearing cycle life for an

  15. Creating nanoshell on the surface of titanium hydride bead

    Directory of Open Access Journals (Sweden)

    PAVLENKO Vyacheslav Ivanovich

    2016-12-01

    Full Text Available The article presents data on the modification of titanium hydride bead by creating titanium nanoshell on its surface by ion-plasma vacuum magnetron sputtering. To apply titanium nanoshell on the titanium hydride bead vacuum coating plant of multifunctional nanocomposite coatings QVADRA 500 located in the center of high technology was used. Analysis of the micrographs of the original surface of titanium hydride bead showed that the microstructure of the surface is flat, smooth, in addition the analysis of the microstructure of material surface showed the presence of small porosity, roughness, mainly cavities, as well as shallow longitudinal cracks. The presence of oxide film in titanium hydride prevents the free release of hydrogen and fills some micro-cracks on the surface. Differential thermal analysis of both samples was conducted to determine the thermal stability of the initial titanium hydride bead and bead with applied titanium nanoshell. Hydrogen thermal desorption spectra of the samples of the initial titanium hydride bead and bead with applied titanium nanoshell show different thermal stability of compared materials in the temperature range from 550 to 860о C. Titanium nanoshells applied in this way allows increasing the heat resistance of titanium hydride bead – the temperature of starting decomposition is 695о C and temperature when decomposition finishes is more than 1000о C. Modified in this way titanium hydride bead can be used as a filler in the radiation protective materials used in the construction or upgrading biological protection of nuclear power plants.

  16. Amorphous titanium-oxide supercapacitors

    Science.gov (United States)

    Fukuhara, Mikio; Kuroda, Tomoyuki; Hasegawa, Fumihiko

    2016-10-01

    The electric capacitance of an amorphous TiO2-x surface increases proportionally to the negative sixth power of the convex diameter d. This occurs because of the van der Waals attraction on the amorphous surface of up to 7 mF/cm2, accompanied by extreme enhanced electron trapping resulting from both the quantum-size effect and an offset effect from positive charges at oxygen-vacancy sites. Here we show that a supercapacitor, constructed with a distributed constant-equipment circuit of large resistance and small capacitance on the amorphous TiO2-x surface, illuminated a red LED for 37 ms after it was charged with 1 mA at 10 V. The fabricated device showed no dielectric breakdown up to 1,100 V. Based on this approach, further advances in the development of amorphous titanium-dioxide supercapacitors might be attained by integrating oxide ribbons with a micro-electro mechanical system.

  17. Titanium template for scaphoid reconstruction.

    Science.gov (United States)

    Haefeli, M; Schaefer, D J; Schumacher, R; Müller-Gerbl, M; Honigmann, P

    2015-06-01

    Reconstruction of a non-united scaphoid with a humpback deformity involves resection of the non-union followed by bone grafting and fixation of the fragments. Intraoperative control of the reconstruction is difficult owing to the complex three-dimensional shape of the scaphoid and the other carpal bones overlying the scaphoid on lateral radiographs. We developed a titanium template that fits exactly to the surfaces of the proximal and distal scaphoid poles to define their position relative to each other after resection of the non-union. The templates were designed on three-dimensional computed tomography reconstructions and manufactured using selective laser melting technology. Ten conserved human wrists were used to simulate the reconstruction. The achieved precision measured as the deviation of the surface of the reconstructed scaphoid from its virtual counterpart was good in five cases (maximal difference 1.5 mm), moderate in one case (maximal difference 3 mm) and inadequate in four cases (difference more than 3 mm). The main problems were attributed to the template design and can be avoided by improved pre-operative planning, as shown in a clinical case. © The Author(s) 2014.

  18. Impact of chorioamnionitis on exhaled nitric oxide and endotracheal aspirate levels of nitrites-nitrates and interleukin-8 in mechanically ventilated preterm neonates.

    Science.gov (United States)

    Figueras-Aloy, Josep; Salvia-Roiges, Maria Dolors; Rodriguez-Miguélez, J Manuel; Miracle-Echegoyen, Xavier; Botet-Mussons, Francesc; Marín-Soria, J Luís; Carbonell-Estrany, Xavier

    2011-06-01

    To assess the influence of maternal chorioamnionitis on early exhaled nitric oxide (NO) and levels of nitrites-nitrates and interleukin (IL)-8 in endotracheal aspirate fluid in mechanically ventilated preterm neonates. Cross-sectional study. PATIENT-SUBJECT SELECTION: Between September 2007 and August 2009, 54 mechanically ventilated preterm neonates were included. Patients were divided into two groups according to the presence or absence of maternal chorioamnionitis, and those without chorioamnionitis (controls) were further stratified into two subgroups by birth weight nitrates were significantly higher in the chorioamnionitis group than in controls (3.6 vs. 1.07 µmol/L; P = 0.035). Nitrites-nitrates levels were positively correlated with exhaled NO in ppb (ρ = 0.367; P = 0.006). Minute exhaled endogenous NO was significantly higher in the chorioamnionitis group (0.48 vs. 0.27 nl/min/kg; P = 0.021). In mechanically ventilated preterm infants weighing nitrates in endotracheal aspirate fluid. Copyright © 2011 Wiley-Liss, Inc.

  19. Colloidal Plasmonic Titanium Nitride Nanoparticles: Properties and Applications

    DEFF Research Database (Denmark)

    Guler, Urcan; Suslov, Sergey; Kildishev, Alexander V.

    2015-01-01

    Optical properties of colloidal plasmonic titanium nitride nanoparticles are examined with an eye on their photothermal and photocatalytic applications via transmission electron microscopy and optical transmittance measurements. Single crystal titanium nitride cubic nanoparticles with an average ...

  20. Lifetime of titanium filament at constant current

    International Nuclear Information System (INIS)

    Chou, T.S.; Lanni, C.

    1981-01-01

    Titanium Sublimation Pump (TSP) represents the most efficient and the least expensive method to produce Ultra High Vacuum (UHV) in storage rings. In ISABELLE, a proton storage accelerator under construction at Brookhaven National Laboratory, for example, TSP provides a pumping speed for hydrogen of > 2 x 10 6 l/s. Due to the finite life of titanium filaments, new filaments have to be switched in before the end of filament burn out, to ensure smooth operation of the accelerator. Therefore, several operational modes that can be used to activate the TSP were studied. The constant current mode is a convenient way of maintaining constant evaporating rate by increasing the power input while the filament diameter decreases as titanium evaporates. The filaments used in this experiment were standard Varian 916-0024 filaments made of Ti 85%, Mo 15% alloy. During their lifetime at a constant current of 48 amperes, the evaporation rate rose to a maximum at about 10% of their life and then flattened out to a constant value, 0.25 g/hr. The maximum evaporation rate occurs coincidently with the recrystallization of 74% Ti 26% Mo 2 from microstructure crystalline at higher titanium concentration to macrostructure crystalline at lower titanium concentration. As the macrocrystal grows, the slip plane develops at the grain boundary resulting in high resistance at the slip plane which will eventually cause the filament burn out due to local heating

  1. Corrosion Behavior of Titanium Based Ceramic Coatings Deposited on Steels

    OpenAIRE

    Ali, Rania

    2016-01-01

    Titanium based ceramic films are increasingly used as coating materials because of their high hardness, excellent wear resistance and superior corrosion resistance. Using electrochemical and spectroscopic techniques, the electrochemical properties of different coatings deposited on different steels under different conditions were examined in this study. Thin films of titanium nitride (TiN), titanium diboride (TiB2), and titanium boronitride with different boron concentrations (TiBN-1&2) w...

  2. Corrosion of titanium and titanium alloys in spent fuel repository conditions - literature review

    International Nuclear Information System (INIS)

    Aho-Mantila, I.; Haenninen, H.; Aaltonen, P.; Taehtinen, S.

    1985-03-01

    The spent nuclear fuel is planned to be disposed in Finnish bedrock. The canister of spent fuel in waste repository is one barrier to the release of radionuclides. It is possible to choose a canister material with a known, measurable corrosion rate and to make it with thickness allowing corrosion to occur. The other possibility is to use a material which is nearly immune to general corrosion. In this second category there are titanium and titanium alloys which exhibit a very high degree of resistance to general corrosion. In this literature study the corrosion properties of unalloyed titanium, titanium alloyed with palladium and titanium alloyed with molybdenum and nickel are reviewed. The two titanium alloys own in addition to the excellent general corrosion properties outstanding properties against localized corrosion like pitting or crevice corrosion. Stress corrosion cracking and corrosion fatique of titanium seem not to be a problem in the repository conditions, but the possibilities of delayed cracking caused by hydrogen should be carefully appreciated. (author)

  3. Array of titanium dioxide nanostructures for solar energy utilization

    Science.gov (United States)

    Qiu, Xiaofeng; Parans Paranthaman, Mariappan; Chi, Miaofang; Ivanov, Ilia N; Zhang, Zhenyu

    2014-12-30

    An array of titanium dioxide nanostructures for solar energy utilization includes a plurality of nanotubes, each nanotube including an outer layer coaxial with an inner layer, where the inner layer comprises p-type titanium dioxide and the outer layer comprises n-type titanium dioxide. An interface between the inner layer and the outer layer defines a p-n junction.

  4. Method for synthesis of titanium dioxide nanotubes using ionic liquids

    Science.gov (United States)

    Qu, Jun; Luo, Huimin; Dai, Sheng

    2013-11-19

    The invention is directed to a method for producing titanium dioxide nanotubes, the method comprising anodizing titanium metal in contact with an electrolytic medium containing an ionic liquid. The invention is also directed to the resulting titanium dioxide nanotubes, as well as devices incorporating the nanotubes, such as photovoltaic devices, hydrogen generation devices, and hydrogen detection devices.

  5. Spectroscopy and titanium gettering in SPHEX

    International Nuclear Information System (INIS)

    Cunningham, G.; Giroud, C.; Summers, H.; Commission of the European Communities, Abingdon

    1994-01-01

    SPHEX is a spheromak wherein the toroidal and poloidal currents are generated and sustained by direct current injection from a Marshall gun, and organised by the effect of magnetic relaxation. In the past it has not achieved high temperature (Langmuir probes indicate a flat profile of about 20 eV), and this was thought to be due to radiation from impurities originating in the Marshall gun. For this paper, titanium has been applied to the plasma-facing surface of the flux conserver in an attempt to reduce impurity levels and plasma density. Calibrated spectrometers were used to measure plasma properties and impurity levels, both before and after application of titanium. The titanium is also found to have a surprisingly large effect on the magnetic properties, which gives some evidence regarding the relaxation mechanism. 7 refs., 2 figs., 1 tab

  6. Reaction of titanium polonides with carbon dioxide

    International Nuclear Information System (INIS)

    Abakumov, A.S.; Malyshev, M.L.; Reznikova, N.F.

    1987-01-01

    It has been ascertained that heating titanium and tantalum in carbon dioxide to temperatures of 500 or 800 0 C alters the composition of the gas phase, causing the advent of carbon monoxide and lowering the oxygen content. Investigation of the thermal stability of titanium polonides in a carbon dioxide medium has shown that titanium mono- and hemipolonides are decomposed at temperatures below 350 0 C. The temperature dependence of the vapor pressure of polonium produced in the decomposition of these polonides in a carbon dioxide medium have been determined by a radiotensimetric method. The enthalpy of the process, calculated from this relationship, is close to the enthalpy of vaporization of elementary polonium in vacuo

  7. Environmental effects in titanium aluminide alloys

    International Nuclear Information System (INIS)

    Thompson, A.W.

    1991-01-01

    Environmental effects on titanium aluminide alloys are potentially of great importance for engineering applications of these materials, although little has been published to date on such effects. The primary emphasis in this paper is on hydrogen effects, with a brief reference to oxygen effects. Hydrogen is readily absorbed at elevated temperature into all the titanium aluminide compositions studied to date, in amounts as large as 10 at.%, and on cooling virtually all this hydrogen is precipitated as a hydride phase or phases. The presence of these precipitated hydride plates affects mechanical properties in ways similar to what is observed in other hydride forming materials, although effects per unit volume of hydride are not particularly severe in the titanium aluminides. Microstructure, and thus thermal and mechanical history, plays a major role in controlling the severity of hydrogen effects

  8. Enthalpy of formation of titanium diboride

    International Nuclear Information System (INIS)

    Akhachinskij, V.V.; Chirin, N.A.

    1975-01-01

    The values given in the literature for the enthalpy of the formation of titanium diboride, as obtained experimentally and by theoretical estimation, range between -32 and -74.4 kcal/mol. In this paper the authors use the method of direct synthesis from elements in a Calvet calorimeter to determine the enthalpy of formation, ΔHsub(f) 0 , sub(298), of titanium diboride with the composition Tisub(1.000+-0.002)Bsub(2.056+-0.006)Csub(0.009)Nsub(0.003), which was found to be -76.78+-0.83 kcal/mol. They calculate that ΔHsub(f,298) (TiBsub(2.056)=-76.14+-0.85 kcal/mol. The procedure employed makes it possible to carry out the titanium diboride synthesis reaction with the calorimeter at room temperature

  9. Stainless Steel to Titanium Bimetallic Transitions

    Energy Technology Data Exchange (ETDEWEB)

    Kaluzny, J. A. [Fermilab; Grimm, C. [Fermilab; Passarelli, D. [Fermilab

    2015-01-01

    In order to use stainless steel piping in an LCLS-II (Linac Coherent Light Source Upgrade) cryomodule, stainless steel to titanium bimetallic transitions are needed to connect the stainless steel piping to the titanium cavity helium vessel. Explosion bonded stainless steel to titanium transition pieces and bimetallic transition material samples have been tested. A sample transition tube was subjected to tests and x-ray examinations between tests. Samples of the bonded joint material were impact and tensile tested at room temperature as well as liquid helium temperature. The joint has been used successfully in horizontal tests of LCLS-II cavity helium vessels and is planned to be used in LCLS-II cryomodules. Results of material sample and transition tube tests will be presented.

  10. Failed endotracheal intubation

    Directory of Open Access Journals (Sweden)

    Sheykhol Islami V

    1995-07-01

    Full Text Available The incidence of failed intubation is higher in obstetric than other surgical patients. Failed intubation was the 2nd commonest cause of mortality during anesthesia. Bearing in mind that failre to intubate may be unavoidable in certain circumstances, it is worth reviewing. The factors, which may contribute to a disastrous out come. Priorities of subsequent management must include maintaining oxygenation and preventing aspiration of gastric contents. Fiber optic intubation is now the technique of choice with a high success rate and with least trauma to the patient.

  11. Laser induced single spot oxidation of titanium

    Energy Technology Data Exchange (ETDEWEB)

    Jwad, Tahseen, E-mail: taj355@bham.ac.uk; Deng, Sunan; Butt, Haider; Dimov, S.

    2016-11-30

    Highlights: • A new high resolution laser induced oxidation (colouring) method is proposed (single spot oxidation). • The method is applied to control oxide films thicknesses and hence colours on titanium substrates in micro-scale. • The method enable imprinting high resolution coloured image on Ti substrate. • Optical and morphological periodic surface structures are also produced by an array of oxide spots using the proposed method. • Colour coding of two colours into one field is presented. - Abstract: Titanium oxides have a wide range of applications in industry, and they can be formed on pure titanium using different methods. Laser-induced oxidation is one of the most reliable methods due to its controllability and selectivity. Colour marking is one of the main applications of the oxidation process. However, the colourizing process based on laser scanning strategies is limited by the relative large processing area in comparison to the beam size. Single spot oxidation of titanium substrates is proposed in this research in order to increase the resolution of the processed area and also to address the requirements of potential new applications. The method is applied to produce oxide films with different thicknesses and hence colours on titanium substrates. High resolution colour image is imprinted on a sheet of pure titanium by converting its pixels’ colours into laser parameter settings. Optical and morphological periodic surface structures are also produced by an array of oxide spots and then analysed. Two colours have been coded into one field and the dependencies of the reflected colours on incident and azimuthal angles of the light are discussed. The findings are of interest to a range of application areas, as they can be used to imprint optical devices such as diffusers and Fresnel lenses on metallic surfaces as well as for colour marking.

  12. Laser induced single spot oxidation of titanium

    International Nuclear Information System (INIS)

    Jwad, Tahseen; Deng, Sunan; Butt, Haider; Dimov, S.

    2016-01-01

    Highlights: • A new high resolution laser induced oxidation (colouring) method is proposed (single spot oxidation). • The method is applied to control oxide films thicknesses and hence colours on titanium substrates in micro-scale. • The method enable imprinting high resolution coloured image on Ti substrate. • Optical and morphological periodic surface structures are also produced by an array of oxide spots using the proposed method. • Colour coding of two colours into one field is presented. - Abstract: Titanium oxides have a wide range of applications in industry, and they can be formed on pure titanium using different methods. Laser-induced oxidation is one of the most reliable methods due to its controllability and selectivity. Colour marking is one of the main applications of the oxidation process. However, the colourizing process based on laser scanning strategies is limited by the relative large processing area in comparison to the beam size. Single spot oxidation of titanium substrates is proposed in this research in order to increase the resolution of the processed area and also to address the requirements of potential new applications. The method is applied to produce oxide films with different thicknesses and hence colours on titanium substrates. High resolution colour image is imprinted on a sheet of pure titanium by converting its pixels’ colours into laser parameter settings. Optical and morphological periodic surface structures are also produced by an array of oxide spots and then analysed. Two colours have been coded into one field and the dependencies of the reflected colours on incident and azimuthal angles of the light are discussed. The findings are of interest to a range of application areas, as they can be used to imprint optical devices such as diffusers and Fresnel lenses on metallic surfaces as well as for colour marking.

  13. Titanium Isotopes Provide Clues to Lunar Origin

    Science.gov (United States)

    Taylor, G. J.

    2012-05-01

    The idea that the Moon formed as the result of the giant impact of a Mars-sized impactor with the still-growing Earth explains two central facts about the Earth-Moon system: its total angular momentum (Earth's spin and the Moon's orbital motion), and the sizes of the metallic cores of the Earth (large) and Moon (tiny). This gives cosmochemists some confidence in the hypothesis, but they would greatly appreciate additional compositional tests. One undisputed point is the identical abundance of the three oxygen isotopes in Earth and Moon. Junjun Zhang and colleagues at the University of Chicago (USA) and the University of Bern (Switzerland) have added another isotopic system to the cosmochemical testing tool kit, titanium isotopes. They find that the ratio of titanium-50 to titanium-47 is identical in Earth and Moon to within four parts per million. In contrast, other solar system materials, such as carbonaceous chondrites, vary by considerably more than this-- up to 150 times as much. The identical oxygen and titanium isotopic compositions in Earth and Moon are surprising in light of what we think we know about planet formation and formation of the Moon after a giant impact. The variations in oxygen and titanium isotopes among meteorite types suggest that it is unlikely that the Moon-forming giant impactor would have had the same isotopic composition as the Earth. Simulations show that the Moon ends up constructed mostly (40-75%) from the impactor materials. Thus, the Moon ought to have different isotopic composition than does Earth. The isotopes might have exchanged in the complicated, messy proto-lunar disk (as has been suggested for oxygen isotopes), making them the same. However, Zhang and colleagues suggest that this exchange is unlikely for a refractory element like titanium. Could the impact simulations be greatly overestimating the contributions from the impactor? Was the mixing of building-block materials throughout the inner solar system much less than

  14. Creating mobile apps with Appcelerator Titanium

    CERN Document Server

    Brousseau, Christian

    2013-01-01

    Creating Mobile Apps with Appcelerator Titanium provides a hands-on approach and working examples on creating apps and games as well as embedding them onto a social networking website. Developers can then move on from there to develop their own applications based on the ones they have developed throughout the course of this book.""Creating Mobile Apps with Appcelerator Titanium"" is for developers who have experience with modern languages and development environments. Also, if you are familiar with the concepts of Object-oriented Programming (OOP), reusable components, AJAX closures, and so on

  15. Nickel and titanium nanoboride composite coating

    International Nuclear Information System (INIS)

    Efimova, K A; Galevsky, G V; Rudneva, V V; Kozyrev, N A; Orshanskaya, E G

    2015-01-01

    Electrodeposition conditions, structural-physical and mechanical properties (microhardness, cohesion with a base, wear resistance, corrosion currents) of electroplated composite coatings on the base of nickel with nano and micro-powders of titanium boride are investigated. It has been found out that electro-crystallization of nickel with boride nanoparticles is the cause of coating formation with structural fragments of small sizes, low porosity and improved physical and mechanical properties. Titanium nano-boride is a component of composite coating, as well as an effective modifier of nickel matrix. Nano-boride of the electrolyte improves efficiency of the latter due to increased permissible upper limit of the cathodic current density. (paper)

  16. The Properties of Titanium and Its Alloys

    OpenAIRE

    BIŠĆAN, VLATKA; LUETIĆ, VIKTORIJA

    2012-01-01

    Titanium metal is silver-grey color and high gloss, the ninth element of the abundance in the Earth’s crust, and can be found in meteorites. It has a low electrical conductivity and low coefficient of thermal expansion. Since titanium has a great passivity, its physical property is a high level of corrosion resistance to most mineral acids and chlorides. It has mechanical properties such as steel, has a high melting temperature and is light. Since it is highly resistant to corrosion it is app...

  17. Nickel contaminated titanium weld wire study

    International Nuclear Information System (INIS)

    Coffin, G.R.; Sumstine, R.L.

    1979-01-01

    Attachment of thermocouples to fuel rod welding problems at Exxon Nuclear Company and INEL prompted an investigation study of the titanium filler wire material. It was found that the titanium filler wire was contaminated with nickel which was jacketed on the wire prior to the drawing process at the manufacturers. A method was developed to 100% inspect all filler wire for future welding application. This method not only indicates the presence of nickel contamination but indicates quantity of contamination. The process is capable of high speed inspection necessary for various high speed manufacturing processes

  18. Local heating with titanium nitride nanoparticles

    DEFF Research Database (Denmark)

    Guler, Urcan; Ndukaife, Justus C.; Naik, Gururaj V.

    2013-01-01

    We investigate the feasibility of titanium nitride (TiN) nanoparticles as local heat sources in the near infrared region, focusing on biological window. Experiments and simulations provide promising results for TiN, which is known to be bio-compatible.......We investigate the feasibility of titanium nitride (TiN) nanoparticles as local heat sources in the near infrared region, focusing on biological window. Experiments and simulations provide promising results for TiN, which is known to be bio-compatible....

  19. Phased Array Ultrasonic Inspection of Titanium Forgings

    International Nuclear Information System (INIS)

    Howard, P.; Klaassen, R.; Kurkcu, N.; Barshinger, J.; Chalek, C.; Nieters, E.; Sun, Zongqi; Fromont, F. de

    2007-01-01

    Aerospace forging inspections typically use multiple, subsurface-focused sound beams in combination with digital C-scan image acquisition and display. Traditionally, forging inspections have been implemented using multiple single element, fixed focused transducers. Recent advances in phased array technology have made it possible to perform an equivalent inspection using a single phased array transducer. General Electric has developed a system to perform titanium forging inspection based on medical phased array technology and advanced image processing techniques. The components of that system and system performance for titanium inspection will be discussed

  20. Titanium reinforced boron-polyimide composite

    Science.gov (United States)

    Clark, G. A.; Clayton, K. I.

    1969-01-01

    Processing techniques for boron polyimide prepreg were developed whereby composites could be molded under vacuum bag pressure only. A post-cure cycle was developed which resulted in no loss in room temperature mechanical properties of the composite at any time during up to 16 hours at 650 F. A design utilizing laminated titanium foil was developed to achieve a smooth transition of load from the titanium attachment points into the boron-reinforced body of the structure. The box beam test article was subjected to combined bending and torsional loads while exposed to 650 F. Loads were applied incrementally until failure occurred at 83% design limit load.

  1. Direct dynamic synthesis of nanodispersed phases of titanium oxides upon sputtering of electrodischarge titanium plasma into an air atmosphere

    Science.gov (United States)

    Sivkov, A. A.; Gerasimov, D. Yu.; Nikitin, D. S.

    2017-01-01

    Experimental investigations of the possibility of directly synthesizing nanodispersed crystalline phases of titanium dioxides with rutile and anatase structures in a hypervelocity jet of electroerosion plasma generated by a coaxial magnetoplasma accelerator with titanium electrodes are presented. A powder product containing nanosized polymorphic phases of titanium dioxide with a spherical shape of particles has been manufactured.

  2. [A comparison of degree of precision of auscultation, partial pressure of carbon dioxide in end-expiration, and transillumination technique in verifying accurate position of endotracheal tube].

    Science.gov (United States)

    Qi, Le; Liu, Rong; Tang, Enhui; Li, Shouchun; Jin, Jun; He, Xihuan; Lyu, Shaojun; Weng, Hao

    2015-10-01

    To evaluate the effect of auscultation, partial pressure of carbon dioxide in end-expiration (P(ET)CO2), transillumination technique to judge whether the endotracheal tube is misplaced into the esophagus. A blinded randomized controlled trial was conducted. Sixty patients with American Society of Anesthesiology (ASA) grade I - II undergoing endotracheal intubation in Fengxian Central Hospital admitted from September 2014 to February 2015 were enrolled. Two endotracheal tubes with the same size were respectively inserted into the trachea and esophagus for the same depth after general anesthesia by the same person. Two blinded anesthetists with different experience checked the tube position using three methods including auscultation, P(ET)CO2, and transillumination technique, respectively. The order of the tubes tested (trachea or esophagus) and the method used were randomized according to randomise numbers table. The experienced anesthetists conducted the test first, followed by an inexperienced anesthetist conducting the same methods. The numbers of right and wrong determinations with different methods by different anesthetists were recorded. Sixty patients underwent the procedures for 180 times, with intratracheal intubation for 90 times, and esophageal intubation for 90 times. It was shown that the results were not different in two groups [96.7% (174/180) vs. 92.2% (166/180), χ2 = 3.500, P = 0.057]. By using auscultation, the correct rate of experienced anesthetist was higher than that of inexperienced (95.0% vs. 78.3%, χ2 = 5.786, P = 0.013). Using P(ET)CO2, both anesthetists were correct in all cases, and the accuracy was 100%. Using transillumination, the experienced anesthetist was mistaken in 3 cases (accuracy was 95.0%), while the inexperienced mistook in 1 case (accuracy was 98.3%), and no significant difference was found between two groups χ2 = 0.500, P = 0.250). The correct rate of using transillumination was significantly higher than that of using

  3. [Comparison of endotracheal aspiration and mini-BAL culture results in the diagnosis of ventilator-associated pneumonia].

    Science.gov (United States)

    Artuk, Cumhur; Gül, Hanefi Cem; Mert, Gürkan; Karakaş, Ahmet; Bedir, Orhan; Eyigün, Can Polat

    2012-07-01

    The objective of this study was to compare the results of cultures obtained by mini-bronchoalveolar lavage (BAL) and endotracheal aspiration (ETA) techniques, used for rapid and accurate determination of pathogens causing ventilator-associated pneumonia (VAP) in intensive care units. Of the 92 patients on mechanical ventilation followed at the emergency intensive care unit of our hospital between June 2010 and June 2011, 30 (32.2%) patients were diagnosed as VAP and they were included in this study. VAP diagnosis were based on the clinical and radiological findings. Clinical pulmonary infection score (CPIS) of > 6 was accepted as the clinical criteria of VAP. Initially ETA samples were collected from the patients followed by mini-BAL sampling 15 minutes later, together with urine and two blood cultures. Microbiological evaluation and identification were performed by conventional methods and Phoenix 100 (BD Diagnostic Systems, ABD) automated system. In quantitative culture analysis, > 10.000 cfu/ml for BAL and > 100.000 cfu/ml for ETA were accepted as the positive result. The mean ages of VAP-developed (n= 30; 18 were male) and nondeveloped (n= 62; 39 were male) patients were 68.23 ± 16.19 and 52.16 ± 10.41 years, respectively, and the mean durations of mechanical ventilation were 29.57 ± 15.78 and 12.11 ± 6.01 days, respectively. Multivariate logistic regression analysis showed that older age (pVAP development. There was also a statistically significant difference in CPIS values between patients who developed VAP and not (6.8 ± 1.15 and 2.71 ± 1.06, respectively; pVAP diagnosis was found to be useful in patients on mechanical ventilation. In our study, a total of 16 strains (six A.baumannii, three P.aeruginosa, one K.pneumoniae, six S.aureus) were isolated from ETA cultures, while 34 strains (16 A.baumannii, six P.aeruginosa, four K.pneumoniae, two E.coli, six S.aureus) were isolated from mini-BAL cultures of 30 VAP patients. The contamination rate for ETA

  4. Hydrogen embrittlement of titanium and its alloys - a literature review

    International Nuclear Information System (INIS)

    Aho-Mantila, I.; Haemaelaeinen, H.

    1986-05-01

    Hydrogen embrittlement data of titanium and its alloys is reviewed. Especially the results obtained in spent nuclear fuel repository conditions with commercially pure titanium and TiCode-12 alloy are examined. The results show that the mechanical properties of titanium are not much affected by hydrogen when tested by smooth specimens. Much greater effects can be expected with notched fracture mechanics specimens. However, only limeted data is available. Hydrogen distribution in titanium is affected by stress, alloy composition and temperature gradients. In order to model the hydrogen-induced crack growth in titanium much more mechanistic work is needed especially to understand the behaviour of hydrogen in crack tip stress field. (author)

  5. Structure and properties of Titanium for dental implants

    Directory of Open Access Journals (Sweden)

    M. Greger

    2009-10-01

    Full Text Available This paper describes manufacture of nano-structural titanium, its structure and properties. Nano-titanium has higher specific strength properties than ordinary (coarse-grained titanium. Nano-titanium was produced by the equal-channel angular pressing (ETAP process. The research it self was focused on physical base of strengthening and softening processes and developments occurring at the grain boundaries during the ECAP process at half-hot temperature. Strength of nano-titanium varies around 960 MPa, grain size around 300 nm.

  6. Rough surfaces of titanium and titanium alloys for implants and prostheses

    International Nuclear Information System (INIS)

    Conforto, E.; Aronsson, B.-O.; Salito, A.; Crestou, C.; Caillard, D.

    2004-01-01

    Titanium and titanium alloys for dental implants and hip prostheses were surface-treated and/or covered by metallic or ceramic rough layers after being submitted to sand blasting. The goal of these treatments is to improve the surface roughness and consequently the osteointegration, the fixation, and the stability of the implant. The microstructure of titanium and titanium alloys submitted to these treatments has been studied and correlated to their mechanical behavior. As-treated/covered and mechanically tested surfaces were characterized by scanning electron microscopy (SEM). Structural analyses performed by transmission electron microscopy (TEM), mainly in cross-section, reveal the degree of adherence and cohesion between the surface layer and the substrate (implant). We observed that, although the same convenient surface roughness was obtained with the two types of process, many characteristics as structural properties and mechanical behavior are very different

  7. Rapid PMR determination of hydrogen in titanium hydride and dehydrogenated titanium powders

    International Nuclear Information System (INIS)

    Il'enko, V.S.; Demidenko, L.M.

    1987-01-01

    Proton magnetic resonance (PMR) enables determining hydrogen quantitatively in titanium hydride and dehydrogenated titanium powders without destroying the specimen and is also more informative than high-temperature extraction methods. PMR provides data on the electron-nuclear interactions and the activation energies for hydrogen diffusion while also providing conclusions on the forms and positives of the hydrogen in the lattice and the binding to the metal atoms. The authors have developed a rapid method for determining hydrogen in titanium hydride and dehydrogenated titanium powders which reduces the analysis time and improves the metrological characteristics. The authors use a YaMR-5535 spectrometer working at 40 MHz upgraded for use with hydrogen in solids. The authors used specimens of mass about 2 g ground to 0.1 mm powder

  8. Titanium Metal Powder Production by the Plasma Quench Process

    Energy Technology Data Exchange (ETDEWEB)

    R. A. Cordes; A. Donaldson

    2000-09-01

    The goals of this project included the scale-up of the titanium hydride production process to a production rate of 50 kg/hr at a purity level of 99+%. This goal was to be achieved by incrementally increasing the production capability of a series of reactor systems. This methodic approach was designed to allow Idaho Titanium Technologies to systematically address the engineering issues associated with plasma system performance, and powder collection system design and performance. With quality powder available, actual fabrication with the titanium hydride was to be pursued. Finally, with a successful titanium production system in place, the production of titanium aluminide was to be pursued by the simultaneously injection of titanium and aluminum precursors into the reactor system. Some significant accomplishments of the project are: A unique and revolutionary torch/reactor capable of withstanding temperatures up to 5000 C with high thermal efficiency has been operated. The dissociation of titanium tetrachloride into titanium powder and HC1 has been demonstrated, and a one-megawatt reactor potentially capable of producing 100 pounds per hour has been built, but not yet operated at the powder level. The removal of residual subchlorides and adsorbed HC1 and the sintering of powder to form solid bodies have been demonstrated. The production system has been operated at production rates up to 40 pounds per hour. Subsequent to the end of the project, Idaho Titanium Technologies demonstrated that titanium hydride powder can indeed be sintered into solid titanium metal at 1500 C without sintering aids.

  9. Titanium electroplating of copper in molten salt media

    International Nuclear Information System (INIS)

    Renaud, Denis

    1985-01-01

    After a bibliographical survey on electroplating in molten salt media and on the electrolytic production of titanium, the author explains the reasons for the choice of the LiF-NaF-KF eutectic mix as solvent. He recalls the main properties which are used, and describes the conventional and convolutional processing of data obtained by linear volt-amperometry. He presents the electrolyte preparation mode which takes into account the existence of titanium ions with intermediate oxidation degree, and the reactivity of titanium with oxygenated species. Experimental results are discussed. Then, after the study of the mechanism of reduction of trivalent titanium into titanium on molybdenum (intermetallic diffusion is here negligible), he reports the study of this mechanism on copper (it is a more complicated situation, due to combinations between titanium and copper). The effect of different parameters (electrolyte purity, current density, electrode potential and temperature) is interpreted in order to identify optimal conditions for titanium electroplating of copper [fr

  10. SHORT COMMUNICATION TITANIUM-INDUCED SYNTHESIS OF ...

    African Journals Online (AJOL)

    Preferred Customer

    acyclic alkenes and intramolecular pathway on dicarbonyl compounds to yield ... Table 1, substituted benzofurans 2a-g were obtained in good yield and in the .... The titanium-induced synthesis of benzofurans has proved to be the method of ...

  11. Electrochemical surface modification of titanium in dentistry.

    Science.gov (United States)

    Kim, Kyo-Han; Ramaswamy, Narayanan

    2009-01-01

    Titanium and its alloys have good biocompatibility with body cells and tissues and are widely used for implant applications. However, clinical procedures place more stringent and tough requirements on the titanium surface necessitating artificial surface treatments. Among the many methods of titanium surface modification, electrochemical techniques are simple and cheap. Anodic oxidation is the anodic electrochemical technique while electrophoretic and cathodic depositions are the cathodic electrochemical techniques. By anodic oxidation it is possible to obtain desired roughness, porosity and chemical composition of the oxide. Anodic oxidation at high voltages can improve the crystallinity of the oxide. The chief advantage of this technique is doping of the coating of the bath constituents and incorporation of these elements improves the properties of the oxide. Electrophoretic deposition uses hydroxyapatite (HA) powders dispersed in a suitable solvent at a particular pH. Under these operating conditions these particles acquire positive charge and coatings are obtained on the cathodic titanium by applying an external electric field. These coatings require a post-sintering treatment to improve the coating properties. Cathodic deposition is another type of electrochemical method where HA is formed in situ from an electrolyte containing calcium and phosphate ions. It is also possible to alter structure and/or chemistry of the obtained deposit. Nano-grained HA has higher surface energy and greater biological activity and therefore emphasis is being laid to produce these coatings by cathodic deposition.

  12. Manufacture of titanium and zirconium hydrides

    International Nuclear Information System (INIS)

    Mares, F.; Hanslik, T.

    1973-01-01

    A method is described of manufacturing titanium and zirconium hydrides by hydrogenation of said metals characterized by the reaction temperature ranging between 250 to 500 degC, hydrogen pressure of 20 to 300 atm and possibly by the presence of a hydride of the respective metal. (V.V.)

  13. Titanium impregnated borosilicate zeolites for epoxidation catalysis

    Czech Academy of Sciences Publication Activity Database

    Přech, Jan; Vitvarová, Dana; Lupínková, Lenka; Kubů, Martin; Čejka, Jiří

    2015-01-01

    Roč. 212, AUG 2015 (2015), s. 28-34 ISSN 1387-1811 R&D Projects: GA ČR GAP106/11/0819 Institutional support: RVO:61388955 Keywords : borosilicate * titanium impregnation * epoxidation Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.349, year: 2015

  14. Challenges of titanium metal injection moulding

    CSIR Research Space (South Africa)

    Benson, JM

    2007-11-01

    Full Text Available Titanium has fired the imagination of engineers and designers for decades by its ‘ideal’ combination of high strength, low density and good corrosion resistance. However, its application has unfortunately been limited to those niche markets where...

  15. Evaluating the Johanson theory for titanium powder

    CSIR Research Space (South Africa)

    Chikosha, S

    2015-05-01

    Full Text Available . In this study, the Johanson theory was used to determine the rolling parameters of titanium powder. Preliminary results of the nip angle, nip pressures and maximum horizontal pressures of the mill for the powder rolled on a 55mm diameter roll with roll gap sizes...

  16. Super titanium blades for advanced steam turbines

    International Nuclear Information System (INIS)

    Coulon, P.A.

    1990-01-01

    In 1986, the Alsthom Steam Turbines Department launched the manufacture of large titanium alloy blades: airfoil length of 1360 mm and overall length of 1520 mm. These blades are designed for the last-stage low pressure blading of advanced steam turbines operating at full speed (3000 rpm) and rating between 300 and 800 MW. Using titanium alloys for steam turbine exhaust stages as substitutes for chrome steels, due to their high strength/density ratio and their almost complete resistance to corrosion, makes it possible to increase the length of blades significantly and correspondingly that steam passage section (by up to 50%) with a still conservative stresses level in the rotor. Alsthom relies on 8 years of experience in the field of titanium, since as early as 1979 large titanium blades (airfoil length of 1240 mm, overall length of 1430 mm) were erected for experimental purposes on the last stage of a 900 MW unit of the Dampierre-sur-Loire power plant and now totals 45,000 operating hours without problems. The paper summarizes the main properties (chemical, mechanical and structural) recorded on very large blades and is based in particular on numerous fatigue corrosion test results to justify the use of the Ti 6 Al 4 V alloy in a specific context of micrographic structure

  17. Thermochemically active iron titanium oxide materials

    Energy Technology Data Exchange (ETDEWEB)

    Coker, Eric Nicholas; Miller, James E.

    2018-01-16

    A thermal oxidation-reduction cycle is disclosed that uses iron titanium oxide as the reactive material. The cycle may be used for the thermal splitting of water and/or carbon dioxide to form hydrogen and/or carbon monoxide. The formed compounds may be used as syngas precursors to form fuels.

  18. Obtention of titanium and zirconium metallic

    International Nuclear Information System (INIS)

    Santos, P.R.G.; Rover, C.F.S.; Amaral, F.L.L.

    1988-01-01

    The development works of techniques and equipments for titanium and zirconium sponges obtention are mentioned. The Kroll Process used for the sponges production is described, consisting in the reduction of the metal tetracloride with magnesium in an inert atmosphere of helium or argon. (C.G.C.) [pt

  19. Resorbable versus titanium plates for orthognathic surgery.

    Science.gov (United States)

    Agnihotry, Anirudha; Fedorowicz, Zbys; Nasser, Mona; Gill, Karanjot S

    2017-10-04

    Recognition of some of the limitations of titanium plates and screws used for the fixation of bones has led to the development of plates manufactured from bioresorbable materials. Whilst resorbable plates appear to offer clinical advantages over metal plates in orthognathic surgery, concerns remain about the stability of fixation and the length of time required for their degradation and the possibility of foreign body reactions. This review compares the use of titanium versus bioresorbable plates in orthognathic surgery and is an update of the Cochrane Review first published in 2007. To compare the effects of bioresorbable fixation systems with titanium systems used during orthognathic surgery. Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 20 January 2017); the Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 11) in the Cochrane Library (searched 20 January 2017); MEDLINE Ovid (1946 to 20 January 2017); and Embase Ovid (1980 to 20 January 2017). We searched the US National Institutes of Health Ongoing Trials Register ClinicalTrials.gov (clinicaltrials.gov; searched 20 January 2017), and the World Health Organization International Clinical Trials Registry Platform (searched 20 January 2017) for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. Randomised controlled trials comparing bioresorbable versus titanium fixation systems used for orthognathic surgery in adults. Two review authors independently screened the results of the electronic searches, extracted data and assessed the risk of bias of the included studies. We resolved disagreement by discussion. Clinical heterogeneity between the included trials precluded pooling of data, and only a descriptive summary is presented. This review included two trials, involving 103 participants, one comparing titanium with resorbable plates and screws and

  20. A simple method for accurate endotracheal placement of an intubation tube in Guinea pigs to assess lung injury following chemical exposure.

    Science.gov (United States)

    Nambiar, M P; Gordon, R K; Moran, T S; Richards, S M; Sciuto, A M

    2007-01-01

    ABSTRACT Guinea pigs are considered as the animal model of choice for toxicology and medical countermeasure studies against chemical warfare agents (CWAs) and toxic organophosphate pesticides because of the low levels of carboxylesterase compared to rats and mice. However, it is difficult to intubate guinea pigs without damaging the larynx to perform CWA inhalation experiments. We describe an easy technique of intubation of guinea pigs for accurate endotracheal placement of the intubation tube. The technique involves a speculum made by cutting the medium-size ear speculum in the midline leaving behind the intact circular connector to the otoscope. Guinea pigs were anesthetized with Telazol/meditomidine, the tongue was pulled using blunt forceps, and an otoscope attached with the specially prepared speculum was inserted gently. Insertion of the speculum raises the epiglottis and restrains the movements of vocal cord, which allows smooth insertion of the metal stylet-reinforced intubation tube. Accurate endotracheal placement of the intubation tube was achieved by measuring the length from the tracheal bifurcation to vocal cord and vocal cord to the upper front teeth. The average length of the trachea in guinea pigs (275 +/- 25 g) was 5.5 +/- 0.2 cm and the distance from the vocal cord to the front teeth was typically 3 cm. Coinciding an intubation tube marked at 6 cm with the upper front teeth accurately places the intubation tube 2.5 cm above the tracheal bifurcation. This simple method of intubation does not disturb the natural flora of the mouth and causes minimum laryngeal damage. It is rapid and reliable, and will be very valuable in inhalation exposure to chemical/biological warfare agents or toxic chemicals to assess respiratory toxicity and develop medical countermeasures.

  1. Quantitative culture of endotracheal aspirate and BAL fluid samples in the management of patients with ventilator-associated pneumonia: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Ricardo de Amorim Corrêa

    2014-12-01

    Full Text Available OBJECTIVE: To compare 28-day mortality rates and clinical outcomes in ICU patients with ventilator-associated pneumonia according to the diagnostic strategy used. METHODS: This was a prospective randomized clinical trial. Of the 73 patients included in the study, 36 and 37 were randomized to undergo BAL or endotracheal aspiration (EA, respectively. Antibiotic therapy was based on guidelines and was adjusted according to the results of quantitative cultures. RESULTS: The 28-day mortality rate was similar in the BAL and EA groups (25.0% and 37.8%, respectively; p = 0.353. There were no differences between the groups regarding the duration of mechanical ventilation, antibiotic therapy, secondary complications, VAP recurrence, or length of ICU and hospital stay. Initial antibiotic therapy was deemed appropriate in 28 (77.8% and 30 (83.3% of the patients in the BAL and EA groups, respectively (p = 0.551. The 28-day mortality rate was not associated with the appropriateness of initial therapy in the BAL and EA groups (appropriate therapy: 35.7% vs. 43.3%; p = 0.553; and inappropriate therapy: 62.5% vs. 50.0%; p = 1.000. Previous use of antibiotics did not affect the culture yield in the EA or BAL group (p = 0.130 and p = 0.484, respectively. CONCLUSIONS: In the context of this study, the management of VAP patients, based on the results of quantitative endotracheal aspirate cultures, led to similar clinical outcomes to those obtained with the results of quantitative BAL fluid cultures.

  2. Comparison of prophylactic effects of polyurethane cylindrical or tapered cuff and polyvinyl chloride cuff endotracheal tubes on ventilator-associated pneumonia.

    Directory of Open Access Journals (Sweden)

    Ata Mahmoodpoor

    2013-07-01

    Full Text Available Because microaspiration of contaminated supraglottic secretions past the endotracheal tube cuff is considered to be central in the pathogenesis of pneumonia, improved design of tracheal tubes with new cuff material and shape have reduced the size and number of folds, which together with the addition of suction ports above the cuff to drain pooled subglottic secretions leads to reduced aspiration of oropharyngeal secretions. So we conducted a study to compare the prophylactic effects of polyurethane-cylindrical or tapered cuff and polyvinyl chloride cuff endotracheal tubes (ETT on ventilator-associated pneumonia. This randomized clinical trial was carried out in a 12 bed surgical intensive care unit. 96 patients expected to require mechanical ventilation more than 96 hours were randomly allocated to one of three following groups: Polyvinyl chloride cuff (PCV ETT, Polyurethane (PU cylindrical Sealguard ETT and PU Taperguard ETT. Cuff pressure monitored every three hours 3 days in all patients. Mean cuff pressure didn't have significant difference between three groups during 72 hours. Pneumonia was seen in 11 patients (34% in group PVC, 8 (25% in Sealguard and 7 (21% in Taperguard group. Changes in mean cuff pressure between Sealguard and PVC tubes and also between Taperguard and PVC tubes did not show any significant difference. There was no significant difference in overinflation between three groups. The use of ETT with PU material results in reducing ventilator-associated pneumonia compared to ETT with PVC cuff. In PU tubes Taperguard has less incidence of ventilator-associated pneumonia compared to Sealguard tubes.

  3. Porous titanium bases for osteochondral tissue engineering

    Science.gov (United States)

    Nover, Adam B.; Lee, Stephanie L.; Georgescu, Maria S.; Howard, Daniel R.; Saunders, Reuben A.; Yu, William T.; Klein, Robert W.; Napolitano, Anthony P.; Ateshian, Gerard A.

    2015-01-01

    Tissue engineering of osteochondral grafts may offer a cell-based alternative to native allografts, which are in short supply. Previous studies promote the fabrication of grafts consisting of a viable cell-seeded hydrogel integrated atop a porous, bone-like metal. Advantages of the manufacturing process have led to the evaluation of porous titanium as the bone-like base material. Here, porous titanium was shown to support the growth of cartilage to produce native levels of Young’s modulus, using a clinically relevant cell source. Mechanical and biochemical properties were similar or higher for the osteochondral constructs compared to chondral-only controls. Further investigation into the mechanical influence of the base on the composite material suggests that underlying pores may decrease interstitial fluid pressurization and applied strains, which may be overcome by alterations to the base structure. Future studies aim to optimize titanium-based tissue engineered osteochondral constructs to best match the structural architecture and strength of native grafts. Statement of Significance The studies described in this manuscript follow up on previous studies from our lab pertaining to the fabrication of osteochondral grafts that consist of a bone-like porous metal and a chondrocyte-seeded hydrogel. Here, tissue engineered osteochondral grafts were cultured to native stiffness using adult chondrocytes, a clinically relevant cell source, and a porous titanium base, a material currently used in clinical implants. This porous titanium is manufactured via selective laser melting, offering the advantages of precise control over shape, pore size, and orientation. Additionally, this manuscript describes the mechanical influence of the porous base, which may have applicability to porous bases derived from other materials. PMID:26320541

  4. Rapid prototyped porous nickel–titanium scaffolds as bone substitutes

    Directory of Open Access Journals (Sweden)

    Waldemar Hoffmann

    2014-06-01

    Full Text Available While calcium phosphate–based ceramics are currently the most widely used materials in bone repair, they generally lack tensile strength for initial load bearing. Bulk titanium is the gold standard of metallic implant materials, but does not match the mechanical properties of the surrounding bone, potentially leading to problems of fixation and bone resorption. As an alternative, nickel–titanium alloys possess a unique combination of mechanical properties including a relatively low elastic modulus, pseudoelasticity, and high damping capacity, matching the properties of bone better than any other metallic material. With the ultimate goal of fabricating porous implants for spinal, orthopedic and dental applications, nickel–titanium substrates were fabricated by means of selective laser melting. The response of human mesenchymal stromal cells to the nickel–titanium substrates was compared to mesenchymal stromal cells cultured on clinically used titanium. Selective laser melted titanium as well as surface-treated nickel–titanium and titanium served as controls. Mesenchymal stromal cells had similar proliferation rates when cultured on selective laser melted nickel–titanium, clinically used titanium, or controls. Osteogenic differentiation was similar for mesenchymal stromal cells cultured on the selected materials, as indicated by similar gene expression levels of bone sialoprotein and osteocalcin. Mesenchymal stromal cells seeded and cultured on porous three-dimensional selective laser melted nickel–titanium scaffolds homogeneously colonized the scaffold, and following osteogenic induction, filled the scaffold’s pore volume with extracellular matrix. The combination of bone-related mechanical properties of selective laser melted nickel–titanium with its cytocompatibility and support of osteogenic differentiation of mesenchymal stromal cells highlights its potential as a superior bone substitute as compared to clinically used

  5. Process for making a titanium diboride-chromium diboride-yttrium titanium oxide ceramic composition

    Science.gov (United States)

    Holcombe, C.E.; Dykes, N.L.

    1992-04-28

    A ceramic composition is described. The ceramic composition consists essentially of from about 84 to 96 w/o titanium diboride, from about 1 to 9 w/o chromium diboride, and from about 3 to about 15 w/o yttrium-titanium-oxide. A method of making the ceramic composition is also described. The method of making the ceramic composition comprises the following steps: Step 1--A consolidated body containing stoichiometric quantities of titanium diboride and chromium diboride is provided. Step 2--The consolidated body is enclosed in and in contact with a thermally insulated package of yttria granules having a thickness of at least 0.5 inches. Step 3--The consolidated body enclosed in the thermally insulated package of yttria granules is heated in a microwave oven with microwave energy to a temperature equal to or greater than 1,900 degrees centigrade to sinter and uniformly disperse yttria particles having a size range from about 1 to about 12 microns throughout the consolidated body forming a densified body consisting essentially of titanium diboride, chromium diboride, and yttrium-titanium-oxide. The resulting densified body has enhanced fracture toughness and hardness. No Drawings

  6. Relationship between surface properties (roughness, wettability) of titanium and titanium alloys and cell behaviour

    International Nuclear Information System (INIS)

    Ponsonnet, L.; Reybier, K.; Jaffrezic, N.; Comte, V.; Lagneau, C.; Lissac, M.; Martelet, C.

    2003-01-01

    Cell attachment and spreading to titanium-based alloy surfaces is a major parameter in implant technology. In this paper, substratum surface hydrophobicity, surface free energy, interfacial free energy and surface roughness were investigated to ascertain which of these parameters is predominant in human fibroblast spreading. Two methods for contact angle measurement were compared: the sessile drop method and the captive bubble two-probe method. The relationship between surface roughness and the sessile drop contact angles of various engineered titanium surfaces such as commercial pure titanium (cp-Ti), titanium-aluminium-vanadium alloy (Ti-6Al-4V), and titanium-nickel (NiTi), was shown. Surface free energy (SFE) calculations were performed from contact angles obtained on smooth samples based on the same alloys in order to eliminate the roughness effect. SFE of the surfaces have been calculated using the Owens-Wendt (OW) and Van Oss (VO) approaches with the sessile drop method. The OW calculations are used to obtain the dispersive (γ d ) and polar (γ p ) component of SFE, and the VO approach allows to reach the apolar (γ LW ) and the polar acid-base component (γ ab ) of the surface. From captive bubble contact angle experiments (air or octane bubble under water), the interfacial free energy of the different surfaces in water was obtained. A relationship between cell spreading and the polar component of SFE was found. Interfacial free energy values were low for all the investigated surfaces indicating good biocompatibility for such alloys

  7. Titanium oxide nanocoating on a titanium thin film deposited on a glass substrate

    Energy Technology Data Exchange (ETDEWEB)

    Kotsedi, L., E-mail: kotsedi@tlabs.ac.za [UNESCO-UNISA Africa Chair in Nanosciences-Nanotechnology, College of Graduate Studies, University of South Africa, Muckleneuk Ridge, PO Box 392, Pretoria (South Africa); Nanosciences African Network (NANOAFNET), iThemba LABS, National Research Foundation, 1 Old Faure Road, Somerset West 7129, PO Box 722, Somerset West, Western Cape (South Africa); Nuru, Z.Y. [UNESCO-UNISA Africa Chair in Nanosciences-Nanotechnology, College of Graduate Studies, University of South Africa, Muckleneuk Ridge, PO Box 392, Pretoria (South Africa); Nanosciences African Network (NANOAFNET), iThemba LABS, National Research Foundation, 1 Old Faure Road, Somerset West 7129, PO Box 722, Somerset West, Western Cape (South Africa); Eaton, S.M. [Physics Department, Politecnico di Milano, Piazza Leonardo Da Vinci, 32, 20133 Milano (Italy); Cummings, F.R. [University of the Western Cape, Electron Microscopy Unit, Physics Department, Bellville 7535, Cape Town (South Africa); Turco, S. Lo; Ntwaeaborwa, O.M. [Center for Nano Science and Technology, Istituto Italiano di Tecnologia, Milano, Italy Via Giovanni Pascoli, 70/3, 20133 Milano (Italy); Ramponi, R. [Institute for Photonics and Nanotechnologies (IFN)-CNR, Piazza Leonardo Da Vinci, 32, 20133 Milano (Italy); Maaza, M. [UNESCO-UNISA Africa Chair in Nanosciences-Nanotechnology, College of Graduate Studies, University of South Africa, Muckleneuk Ridge, PO Box 392, Pretoria (South Africa); Nanosciences African Network (NANOAFNET), iThemba LABS, National Research Foundation, 1 Old Faure Road, Somerset West 7129, PO Box 722, Somerset West, Western Cape (South Africa)

    2016-03-31

    Thin films of titanium were deposited on a glass substrate using electron beam evaporator. Femtosecond laser pulses were focused on the surface of the films, and the samples were scanned while mounted on the motorized computer-controlled motion stage to produce an areal modification of the films. X-ray diffraction of the laser-patterned samples showed evidence of the formation of a γ-Ti{sub 3}O{sub 5} with a monoclinic phase. Rutherford backscattering spectrometry simulation showed that there is an increase in the oxygen concentration as the average laser fluence is increased. Time of flight secondary ions mass spectrometry analysis showed an even distribution of the titanium and oxygen ions on the sample and also ionized molecules of the oxides of titanium were observed. The formation of the oxide of titanium was further supported using the UV–Vis-NIR spectroscopy, which showed that for 0.1 J/cm{sup 2} fluence, the laser-exposed film showed the electron transfer band and the d–d transition peak of titanium was observed at lower wavelengths. - Highlights: • γ-Ti{sub 3}O{sub 5} formed using femtosecond laser. • Fluence and oxygen relation were studied. • Nanoflakes of γ-Ti{sub 3}O{sub 5} were observed under HRSEM.

  8. A new method for production of titanium vapor and synthesis of titanium nitride coatings

    Science.gov (United States)

    Grigoriev, Sergey N.; Melnik, Yury A.; Metel, Alexander S.; Volosova, Marina A.

    2018-03-01

    It is proposed to synthesize on machine parts and cutting tools wear-resistant titanium nitride coatings with the help of the hollow-cathode glow discharge, a molybdenum crucible for titanium evaporation being used as the anode of the discharge and a process vacuum chamber being used as the hollow cathode. The research revealed that at the anode surface area less than a critical value S* = (2m/M)1/2S, where S is the area of the chamber walls, m is the mass of electrons and M is the mass of ions, the anode fall of potential is positive and grows from ˜50 V at argon pressure p = 0.2 Pa to ˜2 kV at p = 0.02 Pa. At the discharge current I = 0.6 A electrons accelerated by the anode fall of 0.9 kV transport into the crucible with the inner diameter of 12 mm the power of ˜0.54 kW, which allows the titanium evaporation and the coating deposition rate of 5 µm·h-1 on a substrate distanced from the crucible at 100 mm. After the argon is replaced with the nitrogen, titanium nitride coating without titanium droplets is synthesized the deposition rate amounting to about the same value.

  9. Microstructure evolution of titanium after tensile test

    International Nuclear Information System (INIS)

    Wronski, S.; Wierzbanowski, K.; Jędrychowski, M.; Tarasiuk, J; Wronski, M.; Baczmanski, A.; Bacroix, B.

    2016-01-01

    The qualitative and quantitative behavior of titanium T40 during tensile loading with a special emphasis on the presence of deformation twins in the observed microstructures is described. The samples for tensile tests were cut out from the rolled titanium sheet along the rolling and transverse directions. Several microstructure maps were determined using Electron Backscatter Diffraction technique (EBSD). These data were used to obtain crystallographic textures, misorientation distributions, grain size, twin boundary length, grain orientation spread, low and high angle boundary fractions and Schmid and Taylor factors. The deformation mechanisms and microstructure characteristics are different in the samples stretched along rolling and transverse directions. A strong appearance of tensile twins was observed in the samples deformed along transverse direction. On the other hand, more frequent subgrain formation and higher orientation spread was observed in the sample deformed along rolling direction, which caused’‘orientation blurring’ leading to an increase of grain size with deformation, as determined from OIM analysis.

  10. Requirements of titanium alloys for aeronautical industry

    Science.gov (United States)

    Ghiban, Brânduşa; Bran, Dragoş-Teodor; Elefterie, Cornelia Florina

    2018-02-01

    The project presents the requirements imposed for aeronatical components made from Titanium based alloys. Asignificant portion of the aircraft pylons are manufactured from Titanium alloys. Strength, weight, and reliability are the primary factors to consider in aircraft structures. These factors determine the requirements to be met by any material used to construct or repair the aircraft. Many forces and structural stresses act on an aircraft when it is flying and when it is static and this thesis describes environmental factors, conditions of external aggression, mechanical characteristics and loadings that must be satisfied simultaneously by a Ti-based alloy, compared to other classes of aviation alloys (as egg. Inconel super alloys, Aluminum alloys). For this alloy class, the requirements are regarding strength to weight ratio, reliability, corrosion resistance, thermal expansion and so on. These characteristics additionally continue to provide new opportunities for advanced manufacturing methods.

  11. Aeronautical Industry Requirements for Titanium Alloys

    Science.gov (United States)

    Bran, D. T.; Elefterie, C. F.; Ghiban, B.

    2017-06-01

    The project presents the requirements imposed for aviation components made from Titanium based alloys. A significant portion of the aircraft pylons are manufactured from Titanium alloys. Strength, weight, and reliability are the primary factors to consider in aircraft structures. These factors determine the requirements to be met by any material used to construct or repair the aircraft. Many forces and structural stresses act on an aircraft when it is flying and when it is static and this thesis describes environmental factors, conditions of external aggression, mechanical characteristics and loadings that must be satisfied simultaneously by a Ti-based alloy, compared to other classes of aviation alloys (as egg. Inconel super alloys, Aluminum alloys).For this alloy class, the requirements are regarding strength to weight ratio, reliability, corrosion resistance, thermal expansion and so on. These characteristics additionally continue to provide new opportunities for advanced manufacturing methods.

  12. Titanium implants in irradiated dog mandibles

    International Nuclear Information System (INIS)

    Schweiger, J.W.

    1989-01-01

    The use of osseointegrated titanium implants has been a great benefit to selected cancer patients who otherwise would not be able to wear conventional and/or maxillofacial prostheses. Cognizant of the risk of osteoradionecrosis, we used an animal model to seek experimental evidence for successful osseointegration in bone irradiated to tumoricidal levels. Five healthy male beagle dogs received 60 gray to a previously edentulated and healed area of the right hemimandible. The left hemimandible was kept as a nonirradiated control. After 9 months, titanium implants were placed and allowed an additional 5 1/2 months to osseointegrate. At that time, block specimens were obtained, radiographed, photographed, and analyzed histologically. Although statistical significance cannot be attached to the results, osseointegration was achieved in half of the irradiated specimens

  13. Characterization of titanium alloys for cryogenic applications

    International Nuclear Information System (INIS)

    Reytier, M.; Kircher, F.; Levesy, B.

    2002-01-01

    Titanium alloys are employed in the design of superconducting magnet support systems for their high mechanical strength associated with their low thermal conductivity. But their use requires a careful attention to their crack tolerance at cryogenic temperature. Measurements have been performed on two extra low interstitial materials (Ti-5Al-2.5Sn ELI and Ti-6Al-4V ELI) with different thickness and manufacturing process. The investigation includes the tensile properties at room and liquid helium temperatures using smooth and notched samples. Moreover, the fracture toughness has been determined at 4.2 K using Compact Tension specimens. The microstructure of the different alloys and the various fracture surfaces have also been studied. After a detailed description of the experimental procedures, practical engineering characteristics are given and a comparison of the different titanium alloys is proposed for cryogenic applications

  14. Titanium(IV), zirconium, hafnium and thorium

    International Nuclear Information System (INIS)

    Brown, Paul L.; Ekberg, Christian

    2016-01-01

    Titanium can exist in solution in a number of oxidation states. The titanium(IV) exists in acidic solutions as the oxo-cation, TiO 2+ , rather than Ti 4+ . Zirconium is used in the ceramics industry and in nuclear industry as a cladding material in reactors where its reactivity towards hydrolysis reactions and precipitation of oxides may result in degradation of the cladding. In nature, hafnium is found together with zirconium and as a consequence of the contraction in ionic radii that occurs due to the 4f -electron shell, the ionic radius of hafnium is almost identical to that of zirconium. All isotopes of thorium are radioactive and, as a consequence of it being fertile, thorium is important in the nuclear fuel cycle. The polymeric hydrolysis species that have been reported for thorium are somewhat different to those identified for zirconium and hafnium, although thorium does form the Th 4 (OH) 8 8+ species.

  15. Biofunctionalization of titanium for dental implant

    Directory of Open Access Journals (Sweden)

    Takao Hanawa

    2010-08-01

    Full Text Available Surface modification is an important and predominant technique for obtaining biofunction in metals for biomedical use including dentistry. One surface modification technique is a process that changes the surface composition, structure, and morphology of a material, leaving the bulk mechanical properties intact. A tremendous number of surface modification techniques to improve the hard tissue compatibility of titanium have been developed. Hydroxyapatite layer, titanium oxide layer, and calcium titanate layer with various morphologies are deposited using electrochemical treatment including micro-arc oxidation. Also, surface modification layers without hydroxyapatite and calcium phosphate are chemically formed that accelerate bone formation. Other approach is the immobilization of biofunctional molecules such as poly(ethylene glycol to the metal surface to control the adsorption of proteins and adhesion of cells, platelets, and bacteria. In the case of immobilization of biomolecules such as collagen and peptide, bone formation and soft tissue adhesion are improved.

  16. Characterization of the titanium Kβ spectral profile

    International Nuclear Information System (INIS)

    Chantler, C T; Smale, L F; Kinnane, M N; Illig, A J; Kimpton, J A; Crosby, D N

    2013-01-01

    Transition metals have Kα and Kβ characteristic radiation possessing complex asymmetric spectral profiles. Instrumental broadening normally encountered in x-ray experiments shifts features of profiles used for calibration, such as peak energy, by many times the quoted accuracies. We measure and characterize the titanium Kβ spectral profile. The peak energy of the titanium Kβ spectral profile is found to be 4931.966 ± 0.022 eV prior to instrumental broadening. This 4.5 ppm result decreases the uncertainty over the past literature by a factor of 2.6 and is 2.4 standard deviations from the previous standard. The spectrum is analysed and the resolution-free lineshape is extracted and listed for use in other experiments. We also incorporate improvement in analysis applied to earlier results for V Kβ. (paper)

  17. Antibacterial Titanium Produced Using Selective Laser Melting

    Science.gov (United States)

    Macpherson, Andrew; Li, Xiaopeng; McCormick, Paul; Ren, Ling; Yang, Ke; Sercombe, Timothy B.

    2017-12-01

    Titanium and titanium alloys used in current medical and dental applications do not possess antibacterial properties, and therefore, postoperative infection remains a significant risk. Recently, the addition of silver and copper to conventional biomaterials has been shown to produce a material with good antibacterial properties. In this article, we investigate selective laser melting as a method of producing antibacterial Ti-6Al-4V containing elemental additions of Cu or Ag. The addition of Ag had no effect on the microstructure or strength, but it did result in a 300% increase in the ductility of the alloy. In contrast, the addition of Cu resulted in an increase in strength but in a decrease in ductility, along with a change in the structure of the material. The Cu-containing alloy also showed moderate antibacterial properties and was superior to the Ag-containing alloy.

  18. Standard digital reference images for titanium castings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 The digital reference images provided in the adjunct to this standard illustrate various types and degrees of discontinuities occurring in titanium castings. Use of this standard for the specification or grading of castings requires procurement of the adjunct digital reference images, which illustrate the discontinuity types and severity levels. They are intended to provide the following: 1.1.1 A guide enabling recognition of titanium casting discontinuities and their differentiation both as to type and degree through digital radiographic examination. 1.1.2 Example digital radiographic illustrations of discontinuities and a nomenclature for reference in acceptance standards, specifications and drawings. 1.2 The digital reference images consist of seventeen digital files each illustrating eight grades of increasing severity. The files illustrate seven common discontinuity types representing casting sections up to 1-in. (25.4-mm). 1.3 The reference radiographs were developed for casting sections up to 1...

  19. Precipitated nanosized titanium dioxide for electrochemical applications

    Energy Technology Data Exchange (ETDEWEB)

    Kirillov, S.A. [Joint Department of Electrochemical Energy Systems, 38A Vernadsky Ave., 03142 Kyiv (Ukraine); Institute for Sorption and Problems of Endoecology, 13 Gen. Naumov St., 03164 Kyiv (Ukraine); Lisnycha, T.V. [Institute for Sorption and Problems of Endoecology, 13 Gen. Naumov St., 03164 Kyiv (Ukraine); Chernukhin, S.I. [Joint Department of Electrochemical Energy Systems, 38A Vernadsky Ave., 03142 Kyiv (Ukraine)

    2011-02-15

    Two types of titanium dioxide samples precipitated from aqueous solutions of titanium tetrachloride are investigated. Crystalline materials are obtained by means of neutralization of TiCl{sub 4} with the solution of an alkali metal hydroxide. The change of the order of mixing leads to amorphous materials. The evolution of the samples upon the thermal treatment is characterized using XRD, SEM, TEM and porosity studies. The application of crystalline TiO{sub 2} as an electrode material in lithium-ion 2016 sample cells enable one to yield specific currents up to 3350 mA g{sup -1}. On the other hand, the thermal treatment of initially amorphous materials does not lead to complete crystallization, and the presence of amorphous TiO{sub 2} is well seen as the so-called capacity behavior of cyclic voltammetry curves. (author)

  20. Temperature effect on surface oxidation of titanium

    International Nuclear Information System (INIS)

    Vaquilla, I.; Barco, J.L. del; Ferron, J.

    1990-01-01

    The effect of temperature on the first stages of the superficial oxidation of polycrystalline titanium was studied using both Auger electron spectroscopy (AES) and emission shreshold (AEAPS). The number of compounds present on the surface was determined by application of the factor analysis technique. Reaction evolution was followed through the relative variation of Auger LMM and LMV transitions which are characteristic of titanium. Also the evolution of the chemical shift was determined by AEAPS. The amount of oxygen on the surface was quantified using transition KLL of oxygen. It was found that superficial oxidation depends on temperature. As much as three different compounds were determined according to substrate temperature and our exposure ranges. (Author). 7 refs., 5 figs

  1. Preparation procedure for spherical titanium powders by RF induction plasma

    International Nuclear Information System (INIS)

    Gu Zhongtao; Jin Yuping; Ye Gaoying

    2011-01-01

    The paper uses the single-factor method for the study of spherical titanium powder preparation process. Titanium powders with excellent sphericity can be prepared through controlling and regulating the radio frequency plasma anode working current and voltage, central gas flow rate, sheath gas flow rate, powder-carrying gas flow rate, negative ventilation pressure and powder feed rate, etc. Spheroidization of titanium powders with a size of (17.0±2.0) μm is performed by radio frequency plasma technology. With the increase of negative ventilation pressure, the spheroidization rate of titanium powders increases firstly and then decreases rapidly at the turning point around 1800 Pa. With the rate of powder feed increasing, the spheroidization rate of titanium powders increases firstly. When the powder feed rate is greater than 90.0 g/min, the spheroidization rate of titanium powders reduces rapidly as the powder feed rate increases. (authors)

  2. Fatigue Strength of Titanium Risers - Defect Sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Babalola, Olusegun Tunde

    2001-07-01

    This study is centred on assessment of the fatigue strength of titanium fusion welds for deep-water riser's applications. Deep-water risers are subjected to significant fatigue loading. Relevant fatigue data for titanium fusion welds are very scarce. Hence there is a need for fatigue data and life prediction models for such weldments. The study has covered three topics: Fatigue testing, Fractography and defect assessment, and Fracture Mechanics modelling of fatigue crack growth. Two series of welded grade of titanium consisting of 14 specimens in each series were fatigue tested under constant amplitude loading. Prior to fatigue testing, strain gauge measurements of some specimens was conducted to enable the definition of stress range in the fatigue assessment procedure. The results were compared with finite solid element analysis and related to fatigue stresses in a riser pipe wall. Distribution and geometry of internal and surface defects both in the as-welded and in the post-weld machined conditions were assessed using fractography. This served as a tool to determine the fatigue initiation point in the welds. Fracture mechanics was applied to model fatigue strength of titanium welds with initiation from weld defects. Two different stress intensity factor formulations for embedded eccentrically placed cracks were used for analysis of elliptical cracks with the major axis parallel and close to one of the free surfaces. The methods were combined to give a satisfactory model for crack growth analysis. The model analyses crack growth of elliptical and semi-elliptical cracks in two directions, with updating of the crack geometry. Fatigue strength assessment was conducted using two crack growth models, the Paris-Erdogan relation with no threshold and the Donahue et al. relation with an implied threshold. The model was validated against experimental data, with a discussion on the choice of crack growth model. (author)

  3. Titanium 󈨠: Science and Technology. Volume 3

    Science.gov (United States)

    1993-01-01

    Impurities in titanium which affect the performance of LSI devices are alkaline metals (Na, K), radioactive metals(U,Th), and heavy metals (Fe, Ni, Cr...protection system just started, can help to solve this problem and water polution . Of course mother kind of paint is now proposed. Ti remains also...treattent was set with 3 or 4 repeats at randoi arrangeient. The results of tests were lade with latheiathlcal signifi- cant evalution.The radioactive

  4. Titanium Brazing for Structures and Survivability

    Science.gov (United States)

    2007-05-01

    first method ( Weld +HIP) was a tungsten inert gas ( TIG ) weld around the exterior of the Ti- 6Al-4V blocks followed by hot isostatic pressing (HIP) at...beam welding plus hot isostatic pressing (E-beam+HIP) process in the encapsulation of a ceramic within a titanium structure. The testing of the...different joining methods highlighted some definite candidates for the replacement of the E-beam+HIP process , such as the Weld +HIP, and demonstrated

  5. Innovations: laser-cutting nickel-titanium

    Energy Technology Data Exchange (ETDEWEB)

    Dickson, T.R.; Moore, B.; Toyama, N. [LPL Systems, Inc., Mountain View, CA (United States)

    2002-07-01

    Laser-cutting is well established as the preferred method for manufacturing many endovascular medical devices. Sometimes laser processing has been poorly understood by nickel-titanium (NiTi) material suppliers, medical device manufacturers, and device designers, but the field has made important strides in the past several years. A variety of sample, nonspecific applications are presented for cutting tubing and sheet stock. Limiting constraints, key considerations, and areas for future development are identified. (orig.)

  6. Custom-made laser-welded titanium implant prosthetic abutment.

    Science.gov (United States)

    Iglesia-Puig, Miguel A

    2005-10-01

    A technique to create an individually modified implant prosthetic abutment is described. An overcasting is waxed onto a machined titanium abutment, cast in titanium, and joined to it with laser welding. With the proposed technique, a custom-made titanium implant prosthetic abutment is created with adequate volume and contour of metal to support a screw-retained, metal-ceramic implant-supported crown.

  7. Iron-titanium-mischmetal alloys for hydrogen storage

    Science.gov (United States)

    Sandrock, Gary Dale

    1978-01-01

    A method for the preparation of an iron-titanium-mischmetal alloy which is used for the storage of hydrogen. The alloy is prepared by air-melting an iron charge in a clay-graphite crucible, adding titanium and deoxidizing with mischmetal. The resultant alloy contains less than about 0.1% oxygen and exhibits a capability for hydrogen sorption in less than half the time required by vacuum-melted, iron-titanium alloys.

  8. On reaction of titanium polonides with carbon dioxide

    International Nuclear Information System (INIS)

    Abakumov, A.S.; Malyshev, M.L.; Reznikova, N.F.

    1986-01-01

    The reaction between titanium polonides and carbon dioxide has been studied by comparing titanium polonide thermal resistance in vacuum and in carbon dioxide. The investigation has shown that titanium mono- and semipolonides fail at temperatures below 350 deg C. Temperature dependence of polonium vapor pressure prepared at failure of the given polonides is determined by the radiotensiometry in carbon dioxide. Enthalpy calculated for this dependence is close to the enthalpy of elementary polonium evaporation in vacuum

  9. Electrochemical Characterization of Surface Reactions on Biomedical Titanium alloys

    OpenAIRE

    Alkhateeb, Emad Hashim

    2008-01-01

    Titanium and its alloys are successfully used as implant materials for dental, orthopedic and osteosynthesis applications. The processes that take place at the implant tissue interface are important for the acceptance and integration of the implant. This thesis is divided into two parts: the first part deals with surface modification of titanium to improve the osseointegration, and the second part studies metastable pitting of titanium and its alloys. The weakly attached layer of a bone-like ...

  10. Sorption of cesium on titanium and zirconium phosphates

    International Nuclear Information System (INIS)

    Lebedev, V.N.; Mel'nik, N.A.; Rudenko, A.V.

    2003-01-01

    Titanium and zirconium phosphates were prepared from mineral raw materials of the Kola Peninsula. Their capability to recover cesium cations from the model solutions and liquid radioactive waste (LRW) was studied. Titanium phosphate prepared from solutions formed by titanite breakdown demonstrates greater distribution coefficients of cesium as compared to zirconium phosphate. Titanium phosphate as a cheaper agent featuring greater sorption capacity was recommended for treatment of LRW to remove cesium [ru

  11. Niobium Titanium and Copper wire samples

    CERN Multimedia

    2009-01-01

    Two wire samples, both for carrying 13'000Amperes. I sample is copper. The other is the Niobium Titanium wiring used in the LHC magnets. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. Magnet coils are made of copper-clad niobium–titanium cables — each wire in the cable consists of 9’000 niobium–titanium filaments ten times finer than a hair. The cables carry up to 12’500 amps and must withstand enormous electromagnetic forces. At full field, the force on one metre of magnet is comparable ...

  12. A sourcebook of titanium alloy superconductivity

    CERN Document Server

    Collings, E W

    1983-01-01

    In less than two decades the concept of supercon­ In every field of science there are one or two ductivity has been transformed from a laboratory individuals whose dedication, combined with an innate curiosity to usable large-scale applications. In the understanding, permits them to be able to grasp, late 1960's the concept of filamentary stabilization condense, and explain to the rest of us what that released the usefulness of zero resistance into the field is all about. For the field of titanium alloy marketplace, and the economic forces that drive tech­ superconductivity, such an individual is Ted Collings. nology soon focused on niobium-titanium alloys. They His background as a metallurgist has perhaps given him are ductile and thus fabricable into practical super­ a distinct advantage in understanding superconduc­ conducting wires that have the critical currents and tivity in titanium alloys because the optimization of fields necessary for large-scale devices. More than superconducting parameters in ...

  13. Progress in Titanium Metal Powder Injection Molding

    Directory of Open Access Journals (Sweden)

    Randall M. German

    2013-08-01

    Full Text Available Metal powder injection molding is a shaping technology that has achieved solid scientific underpinnings. It is from this science base that recent progress has occurred in titanium powder injection molding. Much of the progress awaited development of the required particles with specific characteristics of particle size, particle shape, and purity. The production of titanium components by injection molding is stabilized by a good understanding of how each process variable impacts density and impurity level. As summarized here, recent research has isolated the four critical success factors in titanium metal powder injection molding (Ti-MIM that must be simultaneously satisfied—density, purity, alloying, and microstructure. The critical role of density and impurities, and the inability to remove impurities with sintering, compels attention to starting Ti-MIM with high quality alloy powders. This article addresses the four critical success factors to rationalize Ti-MIM processing conditions to the requirements for demanding applications in aerospace and medical fields. Based on extensive research, a baseline process is identified and reported here with attention to linking mechanical properties to the four critical success factors.

  14. Shock response of a gamma titanium aluminide

    International Nuclear Information System (INIS)

    Shazly, Mostafa; Prakash, Vikas

    2008-01-01

    Potential use of γ-TiAl alloys in aerospace and other structural applications require knowledge of their impact behavior for better evaluation and modeling. In the present study plate impact experiments are conducted using a single-stage gas gun to better understand the shock behavior of the recently developed class of gamma titanium aluminide alloys--the Gamma-Met PX. The Gamma-Met PX showed superior shock properties when compared to the conventional titanium aluminide alloys. The spall strength of Gamma-Met PX is 1.8±0.09 GPa, which is four to six times higher than those reported for other gamma titanium aluminide alloys. Moreover, it has a Hugoniot elastic limit of 1.88 GPa at a target thickness of 3.86 mm, which drops to 1.15 GPa at target thickness of 15.8 mm. The decay in the elastic precursor is continuous without showing an asymptote to a constant level within the range of target thicknesses studied

  15. Titanium oxidation by rf inductively coupled plasma

    International Nuclear Information System (INIS)

    Valencia-Alvarado, R; López-Callejas, R; Barocio, S R; Mercado-Cabrera, A; Peña-Eguiluz, R; Muñoz-Castro, A E; Rodríguez-Méndez, B G; De la Piedad-Beneitez, A; De la Rosa-Vázquez, J M

    2014-01-01

    The development of titanium dioxide (TiO 2 ) films in the rutile and anatase phases is reported. The films have been obtained from an implantation/diffusion and sputtering process of commercially pure titanium targets, carried out in up to 500 W plasmas. The experimental outcome is of particular interest, in the case of anatase, for atmospheric pollution degradation by photocatalysis and, as to the rutile phase, for the production of biomaterials required by prosthesis and implants. The reactor employed consists in a cylindrical pyrex-like glass vessel inductively coupled to a 13.56 MHz RF source. The process takes place at a 5×10 −2 mbar pressure with the target samples being biased from 0 to -3000 V DC. The anatase phase films were obtained from sputtering the titanium targets over glass and silicon electrically floated substrates placed 2 cm away from the target. The rutile phase was obtained by implantation/diffusion on targets at about 700 °C. The plasma was developed from a 4:1 argon/oxygen mixture for ∼5 hour processing periods. The target temperature was controlled by means of the bias voltage and the plasma source power. The obtained anatase phases did not require annealing after the plasma oxidation process. The characterization of the film samples was conducted by means of x-ray diffraction, scanning electron microscopy, x-ray photoelectron spectroscopy and Raman spectroscopy

  16. On the principles of microstructure scale development for titanium alloys

    International Nuclear Information System (INIS)

    Kolachev, B.A.; Mal'kov, A.V.; Gus'kova, L.N.

    1982-01-01

    Analysis of an existing standard scale of microstructures for two-phase (α+#betta#)-titanium alloy semiproducts is given. The basic principles of development of control microstructure scales for titanium alloys are presented on the base of investigations and generalization of literature data on connection of microstructure of titanium intermediate products from (α+#betta#)-alloys with their mechanical properties and service life characteristics. A possibilities of changing mechanical and operating properties at the expense of obtaining qualitatively and quantitatively regulated microstructure in the alloy are disclosed on the example of the (α+#betta#)-titanium alloy

  17. Cold Spraying of Armstrong Process Titanium Powder for Additive Manufacturing

    Science.gov (United States)

    MacDonald, D.; Fernández, R.; Delloro, F.; Jodoin, B.

    2017-04-01

    Titanium parts are ideally suited for aerospace applications due to their unique combination of high specific strength and excellent corrosion resistance. However, titanium as bulk material is expensive and challenging/costly to machine. Production of complex titanium parts through additive manufacturing looks promising, but there are still many barriers to overcome before reaching mainstream commercialization. The cold gas dynamic spraying process offers the potential for additive manufacturing of large titanium parts due to its reduced reactive environment, its simplicity to operate, and the high deposition rates it offers. A few challenges are to be addressed before the additive manufacturing potential of titanium by cold gas dynamic spraying can be reached. In particular, it is known that titanium is easy to deposit by cold gas dynamic spraying, but the deposits produced are usually porous when nitrogen is used as the carrier gas. In this work, a method to manufacture low-porosity titanium components at high deposition efficiencies is revealed. The components are produced by combining low-pressure cold spray using nitrogen as the carrier gas with low-cost titanium powder produced using the Armstrong process. The microstructure and mechanical properties of additive manufactured titanium components are investigated.

  18. High temperature evaporation of titanium, zirconium and hafnium carbides

    International Nuclear Information System (INIS)

    Gusev, A.I.; Rempel', A.A.

    1991-01-01

    Evaporation of cubic nonstoichiometric carbides of titanium, zirconium and hafnium in a comparatively low-temperature interval (1800-2700) with detailed crystallochemical sample certification is studied. Titanium carbide is characterized by the maximum evaporation rate: at T>2300 K it loses 3% of sample mass during an hour and at T>2400 K titanium carbide evaporation becomes extremely rapid. Zirconium and hafnium carbide evaporation rates are several times lower than titanium carbide evaporation rates at similar temperatures. Partial pressures of metals and carbon over the carbides studied are calculated on the base of evaporation rates

  19. In situ hydride formation in titanium during focused ion milling.

    Science.gov (United States)

    Ding, Rengen; Jones, Ian P

    2011-01-01

    It is well known that titanium and its alloys are sensitive to electrolytes and thus hydrides are commonly observed in electropolished foils. In this study, focused ion beam (FIB) milling was used to prepare thin foils of titanium and its alloys for transmission electron microscopy. The results show the following: (i) titanium hydrides were observed in pure titanium, (ii) the preparation of a bulk sample in water or acid solution resulted in the formation of more hydrides and (iii) FIB milling aids the precipitation of hydrides, but there were never any hydrides in Ti64 and Ti5553.

  20. Phase equilibria and thermodynamic studies in the titanium-nickel and titanium-nickel-oxygen systems

    International Nuclear Information System (INIS)

    Chattopadhyay, G.; Kleykamp, H.; Laumer, W.

    1983-01-01

    The isothermal section of the Ti-Ni-O system was examined at 1200 K in the regions between the Ni(Ti) solid solution and the binary oxides of titanium. The relative partial Gibbs energies of oxygen over the Ti 2 O 3 -Ti 3 O 5 region and of titanium in the Ni(Ti) solid solution as well as the Gibbs energies of formation of NiTiO 3 , Ti 3 O 5 and TiNi 3 were determined between 1100 and 1300 K by use of solid electrolyte galvanic cells. (orig.) [de

  1. Hands-Off Time for Endotracheal Intubation during CPR Is Not Altered by the Use of the C-MAC Video-Laryngoscope Compared to Conventional Direct Laryngoscopy. A Randomized Crossover Manikin Study.

    Directory of Open Access Journals (Sweden)

    Philipp Schuerner

    Full Text Available Sufficient ventilation and oxygenation through proper airway management is essential in patients undergoing cardio-pulmonary resuscitation (CPR. Although widely discussed, securing the airway using an endotracheal tube is considered the standard of care. Endotracheal intubation may be challenging and causes prolonged interruption of chest compressions. Videolaryngoscopes have been introduced to better visualize the vocal cords and accelerate intubation, which makes endotracheal intubation much safer and may contribute to intubation success. Therefore, we aimed to compare hands-off time and intubation success of direct laryngoscopy with videolaryngoscopy (C-MAC, Karl Storz, Tuttlingen, Germany in a randomized, cross-over manikin study.Twenty-six anesthesia residents and twelve anesthesia consultants of the University Hospital Zurich were recruited through a voluntary enrolment. All participants performed endotracheal intubation using direct laryngoscopy and C-MAC in a random order during ongoing chest compressions. Participants were strictly advised to stop chest compression only if necessary.The median hands-off time was 1.9 seconds in direct laryngoscopy, compared to 3 seconds in the C-MAC group. In direct laryngoscopy 39 intubation attempts were recorded, resulting in an overall first intubation attempt success rate of 97%, compared to 38 intubation attempts and 100% overall first intubation attempt success rate in the C-MAC group.As a conclusion, the results of our manikin-study demonstrate that video laryngoscopes might not be beneficial compared to conventional, direct laryngoscopy in easily accessible airways under CPR conditions and in experienced hands. The benefits of video laryngoscopes are of course more distinct in overcoming difficult airways, as it converts a potential "blind intubation" into an intubation under visual control.

  2. Hands-Off Time for Endotracheal Intubation during CPR Is Not Altered by the Use of the C-MAC Video-Laryngoscope Compared to Conventional Direct Laryngoscopy. A Randomized Crossover Manikin Study.

    Science.gov (United States)

    Schuerner, Philipp; Grande, Bastian; Piegeler, Tobias; Schlaepfer, Martin; Saager, Leif; Hutcherson, Matthew T; Spahn, Donat R; Ruetzler, Kurt

    2016-01-01

    Sufficient ventilation and oxygenation through proper airway management is essential in patients undergoing cardio-pulmonary resuscitation (CPR). Although widely discussed, securing the airway using an endotracheal tube is considered the standard of care. Endotracheal intubation may be challenging and causes prolonged interruption of chest compressions. Videolaryngoscopes have been introduced to better visualize the vocal cords and accelerate intubation, which makes endotracheal intubation much safer and may contribute to intubation success. Therefore, we aimed to compare hands-off time and intubation success of direct laryngoscopy with videolaryngoscopy (C-MAC, Karl Storz, Tuttlingen, Germany) in a randomized, cross-over manikin study. Twenty-six anesthesia residents and twelve anesthesia consultants of the University Hospital Zurich were recruited through a voluntary enrolment. All participants performed endotracheal intubation using direct laryngoscopy and C-MAC in a random order during ongoing chest compressions. Participants were strictly advised to stop chest compression only if necessary. The median hands-off time was 1.9 seconds in direct laryngoscopy, compared to 3 seconds in the C-MAC group. In direct laryngoscopy 39 intubation attempts were recorded, resulting in an overall first intubation attempt success rate of 97%, compared to 38 intubation attempts and 100% overall first intubation attempt success rate in the C-MAC group. As a conclusion, the results of our manikin-study demonstrate that video laryngoscopes might not be beneficial compared to conventional, direct laryngoscopy in easily accessible airways under CPR conditions and in experienced hands. The benefits of video laryngoscopes are of course more distinct in overcoming difficult airways, as it converts a potential "blind intubation" into an intubation under visual control.

  3. Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.

    Science.gov (United States)

    Akça, Kıvanç; Eser, Atılım; Çavuşoğlu, Yeliz; Sağırkaya, Elçin; Çehreli, Murat Cavit

    2015-05-01

    The aim of this study was to investigate conventionally and early loaded titanium and titanium-zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a localized part of the global model with a refined mesh. The peri-implant tissues around conventionally loaded (model 1) and early loaded (model 2) implants were implemented and were used to explore principal stresses, displacement values, and equivalent strains in the peri-implant region of titanium and titanium-zirconium implants under static load of 300 N with or without 30° inclination applied on top of the abutment surface. Under axial loading, principal stresses in both models were comparable for both implants and models. Under oblique loading, principal stresses around titanium-zirconium implants were slightly higher in both models. Comparable stress magnitudes were observed in both models. The displacement values and equivalent strain amplitudes around both implants and models were similar. Peri-implant bone around titanium and titanium-zirconium implants experiences similar stress magnitudes coupled with intraosseous implant displacement values under conventional loading and early loading simulations. Titanium-zirconium implants have biomechanical outcome comparable to conventional titanium implants under conventional loading and early loading.

  4. Endotracheal intubation with airtraq® versus storz® videolaryngoscope in children younger than two years - a randomized pilot-study

    Directory of Open Access Journals (Sweden)

    Sørensen Martin

    2012-04-01

    Full Text Available Abstract Background New laryngoscopes have become available for use in small children. The aim of the study was to compare the Storz® videolaryngoscope (SVL to the Airtraq® Optical laryngoscope (AOL for tracheal intubation in children younger than two years of age who had a normal airway assessment. Our hypothesis was that the SVL would have a better success rate than the AOL. Methods Ten children aged 2 years or younger scheduled for elective cleft lip/palate surgery were included. The anesthesia was standardized and a Cormack-Lehane (CL-score was obtained using a Macintosh laryngoscope. After randomization CL-score and endotracheal tube positioning in front of the glottis was performed with one device, followed by the same procedure and intubation with the other device. The video-feed was recorded along with real-time audio. The primary endpoint was the success rate, defined as intubation in first attempt. Secondary endpoints were the time from start of laryngoscopy to CL-score, tube positioning in front of the glottis, and intubation. Results Two intubation attempts were needed in two of five patients randomized to the SVL. The difference in time (SVL vs. AOL to CL-score was 4.5 sec (p = 0.0449. The difference in time (SVL vs. AOL to tube positioning was 11.6 sec (p = 0.0015. Time to intubation was 29.0 sec for SVL and 15.8 sec for AOL. Conclusion No difference in the success rate of endotracheal intubation could be established in this ten patient sample of children younger than two years with a normal airway assessment scheduled for elective cleft lip/palate surgery. However, the Airtraq® Optical videolaryngoscope showed a number of time related advantages over the Storz® videolaryngoscope. Because of the small sample size a larger trial is needed to confirm these findings. Both devices were considered safe in all intubations. Trial registration ClinicalTrials.gov; Identifier NCT01090726.

  5. Comparison the Effects of Shallow and Deep Endotracheal Tube Suctioning on Respiratory Rate, Arterial Blood Oxygen Saturation and Number of Suctioning in Patients Hospitalized in the Intensive Care Unit: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasinia

    2014-09-01

    Full Text Available Introduction: Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR, arterial blood oxygen saturation (SpO2 and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. Methods: In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA, chi-square and independent t-tests. Results: RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion: Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient’s trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.

  6. Comparison the effects of shallow and deep endotracheal tube suctioning on respiratory rate, arterial blood oxygen saturation and number of suctioning in patients hospitalized in the intensive care unit: a randomized controlled trial.

    Science.gov (United States)

    Abbasinia, Mohammad; Irajpour, Alireza; Babaii, Atye; Shamali, Mehdi; Vahdatnezhad, Jahanbakhsh

    2014-09-01

    Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR), arterial blood oxygen saturation (SpO2) and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA), chi-square and independent t-tests. RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion : Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient's trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.

  7. High pressure sintering (HP-HT) of diamond powders with titanium and titanium carbide

    International Nuclear Information System (INIS)

    Jaworska, L.

    1999-01-01

    Polycrystalline diamond compacts for cutting tools are mostly manufactured using high pressure sintering (HP-HT). The standard diamond compacts are prepared by diamond powders sintering with metallic binding phase. The first group of metallic binder are metals able to solve carbon - Co, Ni. The second group of metal binders are carbide forming elements - Ti, Cr, W and others. The paper describes high pressure sintering of diamond powder with titanium and nonstoichiometry titanium carbide for cutting tool application. A type of binding phase has the significant influence on microstructure and mechanical properties of diamond compacts. Very homogeneous structure was achieved in case of compacts obtained from metalized diamond where diamond-TiC-diamond connection were predominant. In the case of compacts prepared by mechanical mixing of diamond with titanium powders the obtained structure was nonhomogeneous with titanium carbide clusters. They had more diamond to diamond connections. These compacts compared to the compact made of metallized diamond have greater wear resistance. In the case of the diamond and TiC 0.92 sintering the strong bonding of TiC diamond grains was obtained. The microstructure observations for diamond with 5% wt. Ti and diamond with 5% wt. TiC 0.92 (the initial composition) compacts were performed in transmission microscope. For two type of compacts the strong bonding phase TiC without defects is creating. (author)

  8. Formation of titanium nitride layers on titanium metal: Results of XPS and AES investigations

    International Nuclear Information System (INIS)

    Moers, H.; Pfennig, G.; Klewe-Nebenius, H.; Penzhorn, R.D.; Sirch, M.; Willin, E.

    1988-09-01

    The reaction of titanium metal with gaseous nitrogen and ammonia at temperatures of 890 0 C leads to the formation of nitridic overlayers on the metallic substrate. The thicknesses of the overlayers increase with increasing reaction time. Under comparable conditions ammonia reacts much slower than nitrogen. XPS and AES depth profile analyses show continuous changes of the in-depth compositions of the overlayers. This can be interpreted in terms of a very irregular thickness of the overlayers, an assumption which is substantiated by local AES analyses and by the observation of a pronounced crystalline structure of the substrate after annealing pretreatment, which can give rise to locally different reaction rates. The depth profile is also influenced by the broad ranges of stability of the titanium nitride phases formed during the reaction. The quantitative analysis of the titanium/nitrogen overlayers by AES is difficult because of the overlap of titanium and nitrogen Auger peaks. In quantitative XPS analysis problems arise due to difficulties in defining Ti 2p peak areas. This work presents practical procedures for the quantitative evaluation by XPS and AES of nitridic overlayers with sufficient accuracy. (orig.) [de

  9. In situ formation of titanium carbide using titanium and carbon-nanotube powders by laser cladding

    International Nuclear Information System (INIS)

    Savalani, M.M.; Ng, C.C.; Li, Q.H.; Man, H.C.

    2012-01-01

    Titanium metal matrix composite coatings are considered to be important candidates for high wear resistance applications. In this study, TiC reinforced Ti matrix composite layers were fabricated by laser cladding with 5, 10, 15 and 20 wt% carbon-nanotube. The effects of the carbon-nanotube content on phase composition, microstructure, micro-hardness and dry sliding wear resistance of the coating were studied. Microstructural observation using scanning electron microscopy showed that the coatings consisted of a matrix of alpha-titanium phases and the reinforcement phase of titanium carbide in the form of fine dendrites, indicating that titanium carbide was synthesized by the in situ reaction during laser irradiation. Additionally, measurements on the micro-hardness and dry sliding wear resistance of the coatings indicated that the mechanical properties were affected by the amount of carbon-nanotube in the starting precursor materials and were enhanced by increasing the carbon-nanotube content. Results indicated that the composite layers exhibit high hardness and excellent wear resistance.

  10. Titanium and titanium alloy creep (a bibliography with abstracts). Report for 1964--Jun 1976

    International Nuclear Information System (INIS)

    Smith, M.F.

    1976-08-01

    Research is cited on creep of titanium and its alloys with regard to composition, stress corrosion, fracture, microstructure and tests. Many reports deal with applications to aircraft, spacecraft, and nuclear reactors. (This updated bibliography contains 133 abstracts, 24 of which are new entries to the previous edition.)

  11. In situ formation of titanium carbide using titanium and carbon-nanotube powders by laser cladding

    Energy Technology Data Exchange (ETDEWEB)

    Savalani, M.M., E-mail: mmfsmm@inet.polyu.edu.hk [Department of Industrial and Systems Engineering, Hong Kong Polytechnic University (Hong Kong); Ng, C.C.; Li, Q.H.; Man, H.C. [Department of Industrial and Systems Engineering, Hong Kong Polytechnic University (Hong Kong)

    2012-01-15

    Titanium metal matrix composite coatings are considered to be important candidates for high wear resistance applications. In this study, TiC reinforced Ti matrix composite layers were fabricated by laser cladding with 5, 10, 15 and 20 wt% carbon-nanotube. The effects of the carbon-nanotube content on phase composition, microstructure, micro-hardness and dry sliding wear resistance of the coating were studied. Microstructural observation using scanning electron microscopy showed that the coatings consisted of a matrix of alpha-titanium phases and the reinforcement phase of titanium carbide in the form of fine dendrites, indicating that titanium carbide was synthesized by the in situ reaction during laser irradiation. Additionally, measurements on the micro-hardness and dry sliding wear resistance of the coatings indicated that the mechanical properties were affected by the amount of carbon-nanotube in the starting precursor materials and were enhanced by increasing the carbon-nanotube content. Results indicated that the composite layers exhibit high hardness and excellent wear resistance.

  12. Comparison of titanium cable tension band and nickel-titanium patella concentrator for patella fractures.

    Science.gov (United States)

    Zhao, Quan-Ming; Gu, Xiao-Feng; Cheng, Li; Feng, De-Hong

    2017-07-01

    Patellar fractures account for approximately 1% of all fractures. Due to the patella's importance as regards the extensor mechanism, effort should be made to preserve the patella. Several operative treatment methods have been introduced for patella fractures. This study aims to compare the clinical effect of a titanium cable tension band and nickeltitanium (NiTi) patella concentrator (NT-PC) in treating patella fractures. Thirty-nine patients with patella fractures were enrolled in this retrospective study. All the patients were treated via the open reduction internal fixation procedure using a titanium cable tension band or NT-PC. All the patients were followed up over an average period of 13 months. The main outcome measures were operation time, time of fracture union, postoperative complications, and Böstman knee scores. Statistical analyses were conducted between the 2 groups. All the patients were operated on successfully. The operation time of the NT-PC treatment group was less than that of the titanium cable tension band treatment group (p cable tension band and NT-PC groups, respectively. No significant difference was observed between the excellent and good results (p > 0.05). Both titanium cable tension band and NT-PC showed good efficacy for the treatment of patellar fractures. NT-PC fixation, a new option for the treatment of patella fractures, is a simple and effective fixation method.

  13. Kinetic study of synthesis of Titanium carbide by methano thermal reduction of Titanium dioxide

    International Nuclear Information System (INIS)

    Alizadeh, R.; Ostrovski, O.

    2011-01-01

    Reduction of the Titanium dioxide, TiO 2 , by methane was investigated in this work. The thermodynamic of reaction was examined and found favorable. The reaction of titanium dioxide with methane was carried out in the temperature range 1150 d egree C to 1450 d egree C at atmospheric pressure with industrial high porosity pellets prepared from titanium dioxide powder. The evolved gas analyzing method was used for determination of the extent of reduction rate. The gas products of the reaction are mostly CO and trace amount of CO 2 and H 2 O. The synthesized product powder was characterized by X-ray diffraction for elucidating solid phase compositions. The effect of varying temperature was studied during the reduction. The conversion-time data have been interpreted by using the grain model. For first order reaction with respect to methane concentration, the activation energy of titanium dioxide reduction by methane is found to be 51.4 kcal/g mole. No detailed investigation of kinetic and mechanism of the reaction was reported in literatures.

  14. Effects of thickness on electronic structure of titanium thin films

    Indian Academy of Sciences (India)

    using near-edge X-ray absorption fine structure (NEXAFS) technique at titanium L2,3 edge in total electron yield .... the contribution of titanium L2,3 levels to the absorption co- ... all absorption coefficient of a sample is related to the atomic.

  15. Spark plasma sintering of titanium aluminide intermetallics and its composites

    Science.gov (United States)

    Aldoshan, Abdelhakim Ahmed

    Titanium aluminide intermetallics are a distinct class of engineering materials having unique properties over conventional titanium alloys. gamma-TiAl compound possesses competitive physical and mechanical properties at elevated temperature applications compared to Ni-based superalloys. gamma-TiAl composite materials exhibit high melting point, low density, high strength and excellent corrosion resistance. Spark plasma sintering (SPS) is one of the powder metallurgy techniques where powder mixture undergoes simultaneous application of uniaxial pressure and pulsed direct current. Unlike other sintering techniques such as hot iso-static pressing and hot pressing, SPS compacts the materials in shorter time (< 10 min) with a lower temperature and leads to highly dense products. Reactive synthesis of titanium aluminide intermetallics is carried out using SPS. Reactive sintering takes place between liquid aluminum and solid titanium. In this work, reactive sintering through SPS was used to fabricate fully densified gamma-TiAl and titanium aluminide composites starting from elemental powders at different sintering temperatures. It was observed that sintering temperature played significant role in the densification of titanium aluminide composites. gamma-TiAl was the predominate phase at different temperatures. The effect of increasing sintering temperature on microhardness, microstructure, yield strength and wear behavior of titanium aluminide was studied. Addition of graphene nanoplatelets to titanium aluminide matrix resulted in change in microhardness. In Ti-Al-graphene composites, a noticeable decrease in coefficient of friction was observed due to the influence of self-lubrication caused by graphene.

  16. Radiolysis of titanium potassium oxalate in aqueous solution. [. gamma. rays

    Energy Technology Data Exchange (ETDEWEB)

    Bundo, Y; Ono, I [Industrial Research Inst. of Kanagawa Prefecture, Yokohama (Japan); Ogawa, T

    1975-01-01

    The dissolution state of titanium potassium oxalate in aqueous solution is different according to the pH. The yellowish brown titanium complex produced by the reaction of titanium potassium oxalate and hydrogen peroxide seems to be different in its structure according to the pH. Considering these points, gamma-ray irradiation was carried out on the sample by dissolving titanium potassium oxalate in purified water under the conditions of oxygen saturation and nitrogen saturation, and the relation between irradiation dose and the production of titanium complex was determined. On the basis of the experimental result, the mechanism of forming hydrogen peroxide was presumed. The radiation source used was 2,000 Ci of /sup 60/Co. For photometric analysis, a 139 type photoelectric spectrophotometer of Hitachi Ltd. was used. From the experimental results, in neutral water, titanium potassium oxalate exists in the state that two oxalic acid ions are coordinated to titanyl ion, while in case of the pH lowered by the addition of sulfuric acid, it can exist in the state that one oxalic acid ion is coordinated to titanyl ion. The yield of hydrogen peroxide produced by irradiating titanium potassium oxalate aqueous solution with gamma-ray is the sum of the molecular product from water and the radiolysis product from titanium potassium oxalate.

  17. Classification of titanium dioxide; Clasificacion del dioxido de titanio

    Energy Technology Data Exchange (ETDEWEB)

    Macias B, L.R. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Garcia C, R.M.; Maya M, M.E. [Secretaria de Hacienda y Credito Publico de Mexico, Mexico (Mexico); Ita T, A. De [Universidad Autonoma Metropolitana Azcapotzalco, Mexico (Mexico); Palacios G, J. [Instituto Politecnico Nacional (Mexico)

    2002-07-01

    In this work the X-ray diffraction (XRD), Scanning Electron Microscopy (Sem) and the X-ray Dispersive Energy Spectroscopy techniques are used with the purpose to achieve a complete identification of phases and mixture of phases of a crystalline material as titanium dioxide. The problem for solving consists of being able to distinguish a sample of titanium dioxide being different than a titanium dioxide pigment. A standard sample of titanium dioxide with NIST certificate is used, which indicates a purity of 99.74% for the TiO{sub 2}. The following way is recommended to proceed: a)To make an analysis by means of X-ray diffraction technique to the sample of titanium dioxide pigment and on the standard of titanium dioxide waiting not find differences. b) To make a chemical analysis by the X-ray Dispersive Energy Spectroscopy via in a microscope, taking advantage of the high vacuum since it is oxygen which is analysed and if it is concluded that the aluminium oxide appears in a greater proportion to 1% it is established that is a titanium dioxide pigment, but if it is lesser then it will be only titanium dioxide. This type of analysis is an application of the nuclear techniques useful for the tariff classification of merchandise which is considered as of difficult recognition. (Author)

  18. Microwave assisted scalable synthesis of titanium ferrite nanomaterials

    Science.gov (United States)

    Shukla, Abhishek; Bhardwaj, Abhishek K.; Singh, S. C.; Uttam, K. N.; Gautam, Nisha; Himanshu, A. K.; Shah, Jyoti; Kotnala, R. K.; Gopal, R.

    2018-04-01

    Titanium ferrite magnetic nanomaterials are synthesized by one-step, one pot, and scalable method assisted by microwave radiation. Effects of titanium content and microwave exposure time on size, shape, morphology, yield, bonding nature, crystalline structure, and magnetic properties of titanium ferrite nanomaterials are studied. As-synthesized nanomaterials are characterized by X-ray diffraction (XRD), ultraviolet-visible absorption spectroscopy (UV-Vis), attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR), Raman spectroscopy, transmission electron microscopy (TEM), and vibrating sample magnetometer measurements. XRD measurements depict the presence of two phases of titanium ferrite into the same sample, where crystallite size increases from ˜33 nm to 37 nm with the increase in titanium concentration. UV-Vis measurement showed broad spectrum in the spectral range of 250-600 nm which reveals that its characteristic peaks lie between ultraviolet and visible region; ATR-FTIR and Raman measurements predict iron-titanium oxide structures that are consistent with XRD results. The micrographs of TEM and selected area electron diffraction patterns show formation of hexagonal shaped particles with a high degree of crystallinity and presence of multi-phase. Energy dispersive spectroscopy measurements confirm that Ti:Fe compositional mass ratio can be controlled by tuning synthesis conditions. Increase of Ti defects into titanium ferrite lattice, either by increasing titanium precursor or by increasing exposure time, enhances its magnetic properties.

  19. Hydroxyapatite coating by biomimetic method on titanium alloy ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 28; Issue 6. Hydroxyapatite coating by biomimetic method on titanium alloy using concentrated SBF. S Bharati M K Sinha ... Optical microscopic and SEM observations revealed the deposition of Ca–P layer on the titanium alloy by both the methods. Thickness of coating ...

  20. Studies on the Preparation of Magnetic Photocatalysts

    International Nuclear Information System (INIS)

    Watson, S.; Scott, J.; Beydoun, D.; Amal, R.

    2005-01-01

    A crystalline titanium dioxide coating was deposited onto silica insulated magnetite particles to prepare a stable magnetic photocatalyst. The direct deposition of crystalline titanium dioxide was conducted by aging dispersions of insulated magnetite particles in a titanium sol-gel precursor mixture at 60-90 deg. C. The coating process was found to be influenced by pH, alkoxide precursor concentration, aging time and reaction temperature. A mechanism for the formation of the titanium dioxide coating has been proposed. The photocatalytic performance of the prepared particles was found to be related to the preparation conditions

  1. The effects of preemptive pregabalin on attenuation of stress response to endotracheal intubation and opioid- sparing effect in patients undergoing off-pump coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Ayya Syama Sundar

    2012-01-01

    Full Text Available The clinical study was designed to evaluate and compare single preoperative dose of pregabalin to a placebo regarding hemodynamic responses to laryngoscopy and endotracheal intubation, to assess perioperative fentanyl requirement and any side-effects. It was a randomized, double-blind, placebo-controlled, parallel assignment, efficacy study. The study was done at a tertiary university hospital. This study was a comparison between two groups of 30 adult patients scheduled for elective off pump coronary artery bypass surgery. In the control group, the patients were given placebo capsules, and in the pregabalin group, the patients were given pregabalin 150 mg capsule orally 1 h before surgery. The patients were compared for hemodynamic changes before the start of the surgery, after induction, 1, 3, and 5 min after intubation. Additionally, fentanyl requirement during surgery and the first postoperative day was also compared. The present study shows that a single oral dose of 150 mg pregabalin given 1 h before surgery attenuated the pressor response to tracheal intubation in adults, but the drug did not show any effect on perioperative opioid consumption and was devoid of side-effects in the given dose.

  2. Direct analysis of bacterial viability in endotracheal tube biofilm from a pig model of methicillin-resistant Staphylococcus aureus pneumonia following antimicrobial therapy.

    Science.gov (United States)

    Fernández-Barat, Laia; Li Bassi, Gianluigi; Ferrer, Miquel; Bosch, Anna; Calvo, Maria; Vila, Jordi; Gabarrús, Albert; Martínez-Olondris, Pilar; Rigol, Montse; Esperatti, Mariano; Luque, Néstor; Torres, Antoni

    2012-07-01

    Confocal laser scanning microscopy (CLSM) helps to observe the biofilms formed in the endotracheal tube (ETT) of ventilated subjects and to determine its structure and bacterial viability using specific dyes. We compared the effect of three different treatments (placebo, linezolid, and vancomycin) on the bacterial biofilm viability captured by CLSM. Eight pigs with pneumonia induced by methicillin-resistant Staphylococcus aureus (MRSA) were ventilated up to 96 h and treated with linezolid, vancomycin, or placebo (controls). ETT images were microscopically examined after staining with the live/dead(®) BacLight(™) Kit (Invitrogen, Barcelona, Spain) with a confocal laser scanning microscope. We analyzed 127 images obtained by CLSM. The median ratio of live/dead bacteria was 0.51, 0.74, and 1 for the linezolid, vancomycin, and control groups, respectively (P = 0.002 for the three groups); this ratio was significantly lower for the linezolid group, compared with the control group (P = 0.001). Images showed bacterial biofilm attached and non-attached to the ETT surface but growing within secretions accumulated inside ETT. Systemic treatment with linezolid is associated with a higher proportion of dead bacteria in the ETT biofilm of animals with MRSA pneumonia. Biofilm clusters not necessarily attach to the ETT surface. © 2012 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.

  3. A Comparison of Performance of Endotracheal Intubation Using the Levitan FPS Optical Stylet or Lary-Flex Videolaryngoscope in Morbidly Obese Patients

    Directory of Open Access Journals (Sweden)

    Tomasz Gaszynski

    2014-01-01

    Full Text Available Introduction. The use of videolaryngoscopes is recommended for morbidly obese patients. The aim of the study was to evaluate the Levitan FPS optical stylet (Levitan vs Lafy-Flex videolaryngoscope (Lary-Flex in a group of MO patients. Methods. Seventy-nine MO (BMI>40 kg m−2 patients scheduled for bariatric surgery were included in the study and randomly allocated to the Levitan FPS or Lary-Flex group. The primary endpoint was time to intubation and evaluation laryngoscopic of glottic view. Anesthesiologists were asked to evaluate the glottic view first under direct laryngoscopy using the videolaryngoscope as a standard laryngoscope (monitor display was excluded from use and then using devices. The secondary endpoint was the cardiovascular response to intubation and the participant’s evaluation of such devices. Results. The time to intubation was 8.572.66 sec. versus 5.790.2 sec. for Levitan and Lary-Flex, respectively (P1 under direct laryngoscopy, the study devices improved CL grade to 1. The Levitan FPS produced a greater cardiovascular response than the Lary-Flex videolaryngoscope. Conclusion. The Lary-Flex videolaryngoscope and the Levitan FPS optical stylet improve the laryngeal visualization in morbidly obese patients, allowing for fast endotracheal intubation, but Lary-Flex produces less cardiovascular response to intubation attempt.

  4. A comparison of performance of endotracheal intubation using the Levitan FPS optical stylet or Lary-Flex videolaryngoscope in morbidly obese patients.

    Science.gov (United States)

    Gaszynski, Tomasz; Pietrzyk, Monika; Szewczyk, Tomasz; Gaszynska, Ewelina

    2014-01-01

    The use of videolaryngoscopes is recommended for morbidly obese patients. The aim of the study was to evaluate the Levitan FPS optical stylet (Levitan) vs Lafy-Flex videolaryngoscope (Lary-Flex) in a group of MO patients. Seventy-nine MO (BMI > 40 kg m(-2)) patients scheduled for bariatric surgery were included in the study and randomly allocated to the Levitan FPS or Lary-Flex group. The primary endpoint was time to intubation and evaluation laryngoscopic of glottic view. Anesthesiologists were asked to evaluate the glottic view first under direct laryngoscopy using the videolaryngoscope as a standard laryngoscope (monitor display was excluded from use) and then using devices. The secondary endpoint was the cardiovascular response to intubation and the participant's evaluation of such devices. The time to intubation was 8.572.66 sec. versus 5.790.2 sec. for Levitan and Lary-Flex, respectively (P 1 under direct laryngoscopy, the study devices improved CL grade to 1. The Levitan FPS produced a greater cardiovascular response than the Lary-Flex videolaryngoscope. The Lary-Flex videolaryngoscope and the Levitan FPS optical stylet improve the laryngeal visualization in morbidly obese patients, allowing for fast endotracheal intubation, but Lary-Flex produces less cardiovascular response to intubation attempt.

  5. A Comparative Study of Cuffed Pharyngeal Tube (CPR with Endotracheal Tube in Airway Management and Ventilation of Spontaneously Breathing Patients Undergoing General Anesthesia

    Directory of Open Access Journals (Sweden)

    F Mir Mohammad Sadeghi

    2002-09-01

    Full Text Available Background: Cuffed pharyngeal tube is a device designed for ventilation of anesthetized patients. CPT has advantages over face mask including: maintaining of face mask can be difficult and boring after several minutes and mobility of the practitioner is reduced due to involvement of hands. Mask pressure can cause soft tissue and nerve damage around the nose. Anesthetic gas leakage from the mask adds to the operation room pollution. In difficult intubation CPT can be life-saving. Materials and Methods: In our study CPT was compared with endotracheal tube (ET in anesthetized patients. A scoring system for evaluating ventilation of patients was designed using symmetric chest wall motion during ventilation with anesthesia bag and sensing lung compliance through it, auscultation of breathing sounds, oscilation of bag with breathing and peripheral oxygen saturation by pulse oxymetry. Respiratory complications (pulmonary aspiration, Iaryngospasm and bronchospasm, nausea and vomiting were looked for during anesthesia. Results: The results showed that CPT was successful as ET in ventilation of spontaneously breathing patients and incidence of respiratory complications with CPT was no more than ET. Airway resistance was significantly greater with CPT than ET (P<0.05. Patients with ET had significantly greater incidence of sore throat than with CPT (P<0.05. Conclusion: Thus we concluded that CPT can be used for ventilation of anesthetized patients not predisposed to pulmonary aspiration and whose peak airway pressure does not exceed 20-25 CmH2O.

  6. The incidence of ventilator-associated pneumonia using the PneuX System with or without elective endotracheal tube exchange: A pilot study

    Directory of Open Access Journals (Sweden)

    Blunt Mark

    2011-03-01

    Full Text Available Abstract Background The PneuX System is a novel endotracheal tube and tracheal seal monitor, which has been designed to minimise the aspiration of oropharyngeal secretions. We aimed to determine the incidence of ventilator-associated pneumonia (VAP in patients who were intubated with the PneuX System and to establish whether intermittent subglottic secretion drainage could be performed reliably and safely using the PneuX System. Findings In this retrospective observational study, data was collected from 53 sequential patients. Nine (17% patients were initially intubated with the PneuX System and 44 (83% patients underwent elective exchange to the PneuX System. There were no episodes of VAP while the PneuX System was in situ. On an intention to treat basis, the incidence VAP was 1.8%. There were no complications from, or failure of, subglottic secretion drainage during the study. Conclusions Our study demonstrates that a low incidence of VAP is possible using the PneuX System. Our study also demonstrates that elective exchange and intermittent subglottic secretion drainage can be performed reliably and safely using the PneuX System.

  7. Comparison of endotracheal aspirate and non-bronchoscopic bronchoalveolar lavage in the diagnosis of ventilator-associated pneumonia in a pediatric intensive care unit.

    Science.gov (United States)

    Yıldız-Atıkan, Başak; Karapınar, Bülent; Aydemir, Şöhret; Vardar, Fadıl

    2015-01-01

    Ventilator-associated pneumonia (VAP) is defined as pneumonia occuring in any period of mechanical ventilation. There is no optimal diagnostic method in current use and in this study we aimed to compare two non-invasive diagnostic methods used in diagnosis of VAP in children. This prospective study was conducted in 8 bedded Pediatric Intensive Care Unit at Ege University Children´s Hospital. Endotracheal aspiration (ETA) and non-bronchoscopic bronchoalveolar lavage (BAL) were performed in case of developing VIP after 48 hours of ventilation. Quantitative cultures were examined in Ege University Department of Diagnostic Microbiology, Bacteriology Laboratory. Fourty-one patients were enrolled in the study. The mean age of study subjects was 47.2±53.6 months. A total of 28 in 82 specimens taken with both methods were negative/negative; 28 had positive result with ETA and a negative result with non-bronchoscopic BAL and both results were negative in 26 specimens. There were no patients whose respiratory specimen culture was negative with ETA and positive with non-bronchoscopic BAL. These results imply that there is a significant difference between two diagnostic methods (p VAP; therefore, ETA results were compared with this method. ETA's sensitivity, specificity, negative and positive predictive values were 100%, 50%, 100% and 48% respectively. The study revealed the ease of usability and the sensitivity of non-bronchoscopic BAL, in comparison with ETA.

  8. Effects of stellate ganglion block on cardiovascular reaction and heart rate variability in elderly patients during anesthesia induction and endotracheal intubation.

    Science.gov (United States)

    Chen, Yong-Quan; Jin, Xiao-Ju; Liu, Zhao-Fang; Zhu, Mei-Fang

    2015-03-01

    To investigate the effects of stellate ganglion block (SGB) on cardiovascular response and heart rate (HR) variability in elderly patients during anesthesia induction and endotracheal intubation. A randomized, double-blinded, and placebo-controlled study. University-affiliated teaching hospital. Eighty elderly patients (American Society of Anesthesiologists grades I and II) receiving elective surgery during general anesthesia. Right stellate ganglion injection (SGB) was performed in all patients using 10 mL of 1% lidocaine or normal saline. Systolic blood pressure (BP), diastolic BP, HR, and calculated rate pressure product. HR variability at the following time points: conscious status before induction (T0); immediately before intubation (T1); immediately after intubation (T2); and 1, 3, and 5 minutes postintubation (T3, T4, and T5). No significant differences in BP and HR were observed between the 2 groups. Rate pressure product values significantly increased in the control group compared with baseline and SGB group values. Low-frequency power (LF) and LF/high-frequency power (HF) significantly increased, and HF and normalized units of HF significantly decreased in the control group compared with baseline values. LF, normalized units of LF, and LF/HF in the SGB group significantly decreased compared with those of the control group. SGB protects the myocardium and effectively suppresses stress responses during anesthesia induction and tracheal intubation in elderly patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Morphological findings in the tracheal epithelium of dogs exposed to the inhalation of poorly conditioned gases under use of an endotracheal tube or laryngeal mask airway.

    Science.gov (United States)

    Dias, Norimar Hernandes; Braz, José Reinaldo Cerqueira; Defaveri, Júlio; Carvalho, Lídia Raquel; Martins, Regina Helena Garcia

    2011-10-01

    To study morphological findings in the tracheal epithelium of dogs exposed to the inhalation of poorly conditioned gases under use of an endotracheal tube (ET) or laryngeal mask airway (LMA). Twelve dogs randomly were allocated to two groups: ET group (n-6) and LMA group (n-6), anaesthetized and mechanically ventilated, without CO(2) reabsorption. Haemodynamic and ventilatory parameters, tympanic temperature, temperature, relative and absolute humidity of the ambient and inhaled gases were analyzed during three hours. The animals were submitted to euthanasia and biopsies were carried out along the tracheal segment to morphological study. Three healthy dogs were used to morphological control. Inhaled gas temperature was maintained between 24ºC and 26ºC, relative humidity between 10% and 12%, and absolute humidity between 2 - 3 mg H(2)O.L(-1) with no significant differences between groups. In both groups, histological analysis showed epithelial inflammation and congestion in the corion and scanning electron microscopy showed ciliary grouping and disorganization. Transmission electron microscopy showed higher alterations in ET group than LMA group as widening of cell junctions, ciliary disorientation, cytoplasmic vacuolization, nuclear abnormalities, picnosis and chromatin condensation. LMA determined less pronounced changes in the tracheal epithelium in dogs exposed to the inhalation of poorly conditioned gases.

  10. IMMUNOTOXICOLOGICAL ASPECTS OF BIOCOMPATIBILITY OF TITANIUM

    Directory of Open Access Journals (Sweden)

    Maya Lyapina

    2017-05-01

    Full Text Available Titanium (Ti is a non-essential metal element. TiO2 is used predominantly in the form of micro and nanoparticles in consumer products, including cosmetics and food. Because of its excellent biocompatibility, the trade-pure titan and its alloys are widely used as an alternative to certain metals in invasive medicine, surgery, dental medicine. Contemporary data concerning the sources of exposure to titanium, immune reactions to Ti alloys, current knowledge and perspectives of diagnosis of sensitization or allergic reactions to titanium are discussed. Conclusion: TiO2 is much more stable than pure Ti and alloys used in the implants, that should be taken into account when conducting research and analysing the results. The evidence of possible toxic effects is insufficient. It is difficult to assess the frequency of Ti allergy due to the uncertainty of diagnostic methods, but it is believed that it is very low. This is supported by the evidence that Ti and TiO2 (often as NP doesn’t penetrate through the healthy skin. Skin patch testing with currently available formulations of Ti and TiO2 has no significant value in clinical practice, and currently, it is assumed that there is no reliable method for diagnosis Ti allergy. The functional analysis of cytokine release and investigation of genetic characteristics could be useful for individual risk assessment in dental implantology. Such studies may also help to investigate separately early and late implant loss, as well as to develop new diagnostic tools.

  11. Antibacterial iodine-supported titanium implants.

    Science.gov (United States)

    Shirai, T; Shimizu, T; Ohtani, K; Zen, Y; Takaya, M; Tsuchiya, H

    2011-04-01

    Deep infection remains a serious complication in orthopedic implant surgery. In order to reduce the incidence of implant-associated infections, several biomaterial surface treatments have been proposed. This study focused on evaluating the antibacterial activity of iodine-supported titanium (Ti-I(2)) and its impact on post-implant infection, as well as determining the potential suitability of Ti-I(2) as a biomaterial. External fixation pins were used in this experiment as trial implants because of the ease of making the septic models. The antibacterial activity of the metal was measured using a modification of the Japanese Industrial Standards method. Activity was evaluated by exposing the implants to Staphylococcus aureus or Escherichia coli and comparing reaction of pathogens to Ti-I(2) vs. stainless steel and titanium controls. Ti-I(2) clearly inhibited bacterial colonization more than the control metals. In addition, cytocompatibility was assessed by counting the number of colonies that formed on the metals. The three metals showed the same amount of fibroblast colony formation. Japanese white rabbits were used as an in vivo model. Three pins were inserted into both femora of six rabbits for histological analysis. Pin sites were inspected and graded for infection and inflammation. Fewer signs of infection and inflammatory changes were observed in conjunction with the Ti-I(2) pins. Furthermore, osteoconductivity of the implant was evaluated with osteoid formation surface of the pin. Consecutive bone formation was observed around the Ti-I(2) and titanium pins, while little osteoid formation was found around the stainless steel pins. These findings suggest that Ti-I(2) has antimicrobial activity and exhibits cytocompatibility. Therefore, Ti-I(2) substantially reduces the incidence of implant infection and shows particular promise as a biomaterial. Copyright © 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  12. UV photofunctionalization promotes nano-biomimetic apatite deposition on titanium

    Directory of Open Access Journals (Sweden)

    Saita M

    2016-01-01

    Full Text Available Makiko Saita,1 Takayuki Ikeda,1,2 Masahiro Yamada,1,3 Katsuhiko Kimoto,4 Masaichi Chang-Il Lee,5 Takahiro Ogawa1 1Division of Advanced Prosthodontics, Weintraub Center for Reconstructive Biotechnology, UCLA School of Dentistry, Los Angeles, CA, USA; 2Department of Complete Denture Prosthodontics, Nihon University School of Dentistry, Yokosuka, Japan; 3Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Miyagi, Japan; 4Department of Prosthodontics and Oral Rehabilitation, 5Yokosuka-Shonan Disaster Health Emergency Research Center and ESR Laboratories, Kanagawa Dental University Graduate School of Dentistry, Yokosuka, Japan Background: Although biomimetic apatite coating is a promising way to provide titanium with osteoconductivity, the efficiency and quality of deposition is often poor. Most titanium implants have microscale surface morphology, and an addition of nanoscale features while preserving the micromorphology may provide further biological benefit. Here, we examined the effect of ultraviolet (UV light treatment of titanium, or photofunctionalization, on the efficacy of biomimetic apatite deposition on titanium and its biological capability.Methods and results: Micro-roughed titanium disks were prepared by acid-etching with sulfuric acid. Micro-roughened disks with or without photofunctionalization (20-minute exposure to UV light were immersed in simulated body fluid (SBF for 1 or 5 days. Photofunctionalized titanium disks were superhydrophilic and did not form surface air bubbles when immersed in SBF, whereas non-photofunctionalized disks were hydrophobic and largely covered with air bubbles during immersion. An apatite-related signal was observed by X-ray diffraction on photofunctionalized titanium after 1 day of SBF immersion, which was equivalent to the one observed after 5 days of immersion of control titanium. Scanning electron microscopy revealed nodular apatite deposition

  13. [The bonding characteristic of titanium and RG experiment porcelain].

    Science.gov (United States)

    Ren, Wei-hong; Guo, Tian-wen; Tian, Jie-mo; Zhang, Yun-long

    2003-07-01

    To study the bonding characteristic of Titanium and RG experiment porcelain. 5 specimens with a size of 10 mm x 5 mm x 1.4 mm were cast from pure titanium. Then 1 mm of RG experiment opaque and body porcelain were fused on the surface of the titanium specimens. The interface of titanium and porcelain was analyzed with a scanning electron microscope with energy-despersive spectrometry; 6 metal specimens with the size of 25 mm x 3 mm x 0.5 mm were cast from Ni-Cr alloy and a uniform thickness of 1 mm of VMK 99 porcelain was veneered on the central area of 8 mm x 3 mm 18 metal specimens as the same size were cast from pure titanium. The uniform thickness of 1 mm of VITA TITANKERAMIK porcelain, of Noritake super porcelain Ti-22 and of RG experiment porcelain were veneered on every 6 specimens respectively in the central area of 8 mm x 3 mm. The specimens were subjected to a three-point bending test on a load-test machine with a span of 20 mm, then the failure loads were recorded and statistically analysised. The RG porcelain/titanium crown was fabricated by fusing RG opaque porcelain and body porcelain to cast titanium substrate crown. The SEM results show no porosity and crackle were found in the interface. The energy-dispersive spectrometry show that there are Si, Ti and O in the 1 micro m layer between porcelain and titanium, which suggesting titanium and experiment porcelain bonding well. The three point test showed the fracture force for the combinations of titanium/VITA TITANKERAMIK porcelain, titanium/Noritake super porcelain Ti-22 and titanium/RG experiment porcelain were (7.233 +/- 2.539) N, (5.533 +/- 1.199) N and (6.316 +/- 1.433) N respectively. There were not statistically significant differences among them (t test, P porcelain combination (12.733 +/- 3.297) N was significantly greater than those of the cast titanium/porcelain (t test, P > 0.05). The crown was translucent with no crack. RG porcelain is well compatible with titanium.

  14. ZIRCONIUM-TITANIUM-BERYLLIUM BRAZING ALLOY

    Science.gov (United States)

    Gilliland, R.G.; Patriarca, P.; Slaughter, G.M.; Williams, L.C.

    1962-06-12

    A new and improved ternary alloy is described which is of particular utility in braze-bonding parts made of a refractory metal selected from Group IV, V, and VI of the periodic table and alloys containing said metal as a predominating alloying ingredient. The brazing alloy contains, by weight, 40 to 50 per cent zirconium, 40 to 50 per cent titanium, and the balance beryllium in amounts ranging from 1 to 20 per cent, said alloy having a melting point in the range 950 to 1400 deg C. (AEC)

  15. Crystallization of modified hydroxyapatite on titanium implants

    International Nuclear Information System (INIS)

    Golovanova, O A; Izmailov, R R; Zaits, A V; Ghyngazov, S A

    2016-01-01

    Carbonated-hydroxyapatite (CHA) and Si-hydroxyapatite (Si-HA) precipitation have been synthesized from the model bioliquid solutions (synovial fluid and SBF). It is found that all the samples synthesized from the model solutions are single-phase and represent hydroxyapatite. The crystallization of the modified hydroxyapatite on alloys of different composition, roughness and subjected to different treatment techniques was investigated. Irradiation of the titanium substrates with the deposited biomimetic coating can facilitate further growth of the crystal and regeneration of the surface. (paper)

  16. Laser-TIG Welding of Titanium Alloys

    Science.gov (United States)

    Turichin, G.; Tsibulsky, I.; Somonov, V.; Kuznetsov, M.; Akhmetov, A.

    2016-08-01

    The article presents the results of investigation the technological opportunity of laser-TIG welding of titanium alloys. The experimental stand for implementation of process with the capability to feed a filler wire was made. The research of the nature of transfer the filler wire into the welding pool has been demonstrated. The influence of distance between the electrode and the surface of the welded plates on the stability of the arc was shown. The relationship between welding velocity, the position of focal plane of the laser beam and the stability of penetration of plates was determined.

  17. Diastereoselectivity in scalemic tartrate/titanium epoxidations.

    Science.gov (United States)

    Brown, J M; Leppard, S J; Oakes, J; Thornthwaite, D

    2000-06-01

    Nonlinearity in the diastereoselectivity of epoxidation of allylic alcohols with mixtures of titanium isopropoxide, tertbutyl hydroperoxide, and diethyl tartrate was observed. Racemic and enantiomerically pure alcohols E-2-methyl-4-hexen-3-ol and E-1-methoxy-5-(O-tertbutyldimethylsilyloxy)-2-penten-4-ol were prepared. Epoxidation reactions were carried out with Ti(OPri)4 and ButOOH accompanied by diethyl tartrate of varying enantiomeric purity. The simplest explanation of these results is that a dimeric epoxidation reagent is involved, with significantly different reactivity for the homochiral and racemic forms. Copyright 2000 Wiley-Liss, Inc.

  18. Titanium tungsten coatings for bioelectrochemical applications

    DEFF Research Database (Denmark)

    Wierzbicki, Rafal; Amato, Letizia; Łopacińska, J.

    2011-01-01

    This paper presents an assessment of titanium tungsten (TiW) coatings and their applicability as components of biosensing systems. The focus is put on using TiW as an electromechanical interface layer between carbon nanotube (CNT) forests and silicon nanograss (SiNG) cell scaffolds. Cytotoxicity......, applicability to plasma-enhanced chemical vapor deposition (PECVD) of aligned CNT forests, and electrochemical performance are investigated. Experiments include culturing of NIH3T3 mouse embryonic fibroblast cells on TiW coated silicon scaffolds, CNT growth on TiW substrates with nickel catalyst, and cyclic...

  19. Terminal solid solubility of hydrogen in titanium

    International Nuclear Information System (INIS)

    Giroldi, J.P.; Vizcaino, Pablo; Banchik, Abraham David

    2003-01-01

    A Research and Development program to build a data base is currently under progress to support the local titanium fabrication. In the present work the temperature of the Terminal Solid Solubility on dissolution (TSSd) and precipitation (TSSp) of titanium hydrides in the Ti α-phase were both measured in the same thermal cycle with a Differential Scanning Calorimeter (DSC). The local titanium producer (FAESA) provided ASTM grade 1 pure Ti bars of about 2,5 cm in diameter. Samples weighting between 50 to 200 mg were cut with a diamond disc and the parallelepiped faces were all carefully ground with SiC papers, then picked in a HNO 3 plus HF aqueous solution and finally dried out with ethanol and hot air. Pairs of (TSSd, TSSp) values for α + δ → α and α → α + δ transformation temperatures in titanium were determined with the same calorimetric procedure already used to calculate the TSS values in zirconium. Data were taken from the same sample during the heating up and cooling down cycle of the second calorimeter run made with the same rate of 20 C degrees / minute. The Cathodic Charging technique was used to charge the samples at different hydrogen concentrations between the 'as fabricated' value and the concentration corresponding to the eutectoid temperature. A mixture of glycerin and phosphoric acid in a 2:1 ratio and a current density of 0,05 to 0,1 Amp/cm 2 were applied to different samples during 24 to 96 hours to get a wide range of hydrogen concentrations. A homogenization heat treatment at 400 C degrees for 45 minutes -made at open air in an electric furnace- was applied to each sample to dissolve the massive hydrides at the sample surfaces and diffuse them into the bulk of the sample. The hydrogen concentration of each sample was measured after the final calorimetric run using the Extraction Method in Liquid State under an inert atmosphere using a Leco RH-404 model Hydrogen Determinator. The experimental data follows a linear relationship -with a

  20. Hydrogen in niobium-titanium alloys

    International Nuclear Information System (INIS)

    Silva, J.R.G. da; Cabral, F.A.O.; Florencio, O.

    1985-01-01

    High purity Nb-Ti polycrystalline alloys were doped with hydrogen in equilibrium with the gaseous atmosphere at a pressure of 80 torr. at different temperatures. The partial molar enthalpy and entropy of the hydrogen solution at high dilution, ΔH sup(-) 0 and ΔS sup(-) 0 , were calculated from the equilibrium solubility data. The ΔH sup(-) 0 values are compared with the electron screened proton model of metal-hydrogen solutions. The addition of titanium to niobium has the effect to increase the hydrogen solubility at a given equilibrium temperature. (Author) [pt

  1. Research progress on laser surface modification of titanium alloys

    International Nuclear Information System (INIS)

    Tian, Y.S.; Chen, C.Z.; Li, S.T.; Huo, Q.H.

    2005-01-01

    Recent developments on laser surface modification of titanium and its alloys are reviewed. Due to the intrinsic properties of high coherence and directionality, laser beam can be focus onto metallic surface to perform a broad range of treatments such as remelting, alloying and cladding, which are used to improve the wear and corrosion resistance of titanium alloys. In addition, the fabrication of bioactive films on the surface of titanium alloys to improve their biocompatibility can be performed by the method of laser ablation deposition. The effect of some laser processing parameters on the resulting surface properties of titanium alloys is discussed. The problems to be solved and the prospects in the field of laser modification of titanium and its alloys are elucidated

  2. Corrosion of gold alloys and titanium in artificial saliva

    International Nuclear Information System (INIS)

    Brune, D.; Evje, D.

    1982-01-01

    Two types of gold alloys and one type of pure titanium have been submitted to corrosion in artificial saliva for periods of up to about 2 months. The release of copper, gold and silver from the gold alloys as well as titanium from the titanium matrix was measured with nuclear tracer technique. The physical/chemical state of the corrosion products of gold alloys referring to the ionic state or presence in particulate form has been examined retaining the particulate matter on a glass filter. Copper was observed to be mainly present in the ionic state. Considerable amounts of gold were observed to be retained on the glass filter explained by the presence of gold in particulate form or as a compentent of a dispersed collloidal phase. The estimation of the release of titanium was registered by the tracer nuclide 46 Sc assuming particulate matter to be deteriorated from the titanium surface. (author)

  3. Growth of anatase titanium dioxide nanotubes via anodization

    Directory of Open Access Journals (Sweden)

    Ed Adrian Dilla

    2012-06-01

    Full Text Available In this work, titanium dioxide nanotubes were grown via anodization of sputtered titanium thin films using different anodization parameters in order to formulate a method of producing long anatase titanium dioxide nanotubes intended for solar cell applications. The morphological features of the nanotubes grown via anodization were explored using a Philips XL30 Field Emission Scanning Electron Microscope. Furthermore, the grown nanotubes were also subjected to X-ray diffraction and Raman spectroscopy in order to investigate the effect of the predominant crystal orientation of the parent titanium thin film on the crystal phase of the nanotubes. After optimizing the anodization parameters, nanotubes with anatase TiO2 crystal phase and tube length more than 2 microns was produced from parent titanium thin films with predominant Ti(010 crystal orientation and using ammonium fluoride in ethylene glycol as an electrolyte with a working voltage equal to 60V during 1-hour anodization runs.

  4. Introduction to powder metallurgy processes for titanium manufacturing

    International Nuclear Information System (INIS)

    Esteban, P. G.; Bolzoni, L.; Ruiz-Navas, E. M.; Gordo, E.

    2011-01-01

    The development of new extraction processes to produce titanium in powder form leads Powder Metallurgy to an advantage position among the manufacturing processes for titanium. The cost reduction of base material, coupled with the economy of the powder metallurgy processes, give titanium industry the chance to diversify its products, which could lead to production volumes able to stabilise the price of the metal. This work reviews some of the Powder Metallurgy techniques for the manufacturing of titanium parts, and describes the two typical approaches for titanium manufacturing: Blending Elemental and Prealloyed Powders. Among others, conventional pressing and sintering are described, which are compared with cold and hot isostatic pressing techniques. Real and potential applications are described. (Author) 71 refs.

  5. Osseointegration is improved by coating titanium implants with a nanostructured thin film with titanium carbide and titanium oxides clustered around graphitic carbon

    Energy Technology Data Exchange (ETDEWEB)

    Veronesi, Francesca [Laboratory of Preclinical and Surgical Studies, Rizzoli Orthopedic Institute, Via Di Barbiano 1/10, Bologna 40136 (Italy); Giavaresi, Gianluca; Fini, Milena [Laboratory of Preclinical and Surgical Studies, Rizzoli Orthopedic Institute, Via Di Barbiano 1/10, Bologna 40136 (Italy); Laboratory of Biocompatibility, Innovative Technologies and Advanced Therapies, Department Rizzoli RIT, Via Di Barbiano 1/10, Bologna 40136 (Italy); Longo, Giovanni [CNR Istituto di Struttura della Materia, CNR, Via del Fosso del Cavaliere 100, 00133 Roma (Italy); Ioannidu, Caterina Alexandra; Scotto d' Abusco, Anna [Dept. of Biochemical Sciences, Sapienza University of Roma, Ple A. Moro 5, 00185 Roma (Italy); Superti, Fabiana; Panzini, Gianluca [Dept. of Technologies and Health, Istituto Superiore di Sanità, Viale Regina Elena, 299 Roma (Italy); Misiano, Carlo [Romana Film Sottili, Anzio, Roma (Italy); Palattella, Alberto [Dept. of Clinical Sciences and Translational Medicine, Tor Vergata University, Via Montpellier 1, 00133 Roma (Italy); Selleri, Paolo; Di Girolamo, Nicola [Exotic Animals Clinic, Via S. Giovannini 53, 00137 Roma (Italy); Garbarino, Viola [Dept. of Radiology, S.M. Goretti Hospital, Via G. Reni 2, 04100 Latina (Italy); Politi, Laura [Dept. of Biochemical Sciences, Sapienza University of Roma, Ple A. Moro 5, 00185 Roma (Italy); Scandurra, Roberto, E-mail: roberto.scandurra@uniroma1.it [Dept. of Biochemical Sciences, Sapienza University of Roma, Ple A. Moro 5, 00185 Roma (Italy)

    2017-01-01

    Titanium implants coated with a 500 nm nanostructured layer, deposited by the Ion Plating Plasma Assisted (IPPA) technology, composed of 60% graphitic carbon, 25% titanium oxides and 15% titanium carbide were implanted into rabbit femurs whilst into the controlateral femurs uncoated titanium implants were inserted as control. At four time points the animals were injected with calcein green, xylenol orange, oxytetracycline and alizarin. After 2, 4 and 8 weeks femurs were removed and processed for histology and static and dynamic histomorphometry for undecalcified bone processing into methylmethacrylate, sectioned, thinned, polished and stained with Toluidine blue and Fast green. The overall bone-implant contacts rate (percentage of bone-implant contacts/weeks) of the TiC coated implant was 1.6 fold than that of the uncoated titanium implant. The histomorphometric analyses confirmed the histological evaluations. More precisely, higher Mineral Apposition Rate (MAR, μm/day) (p < 0.005) and Bone Formation Rate (BFR, μm{sup 2}/μm/day) (p < 0.0005) as well as Bone Implant Contact (Bic) and Bone Ingrowth values (p < 0.0005) were observed for the TiC coated implants compared to uncoated implants. In conclusion the hard nanostructured TiC layer protects the bulk titanium implant against the harsh conditions of biological tissues and in the same time, stimulating adhesion, proliferation and activity of osteoblasts, induces a better bone-implant contacts of the implant compared to the uncoated titanium implant. - Highlights: • Ti implants were coated with a nanostructured film composed of C{sub gr}, TiC and TiO{sub x}. • The TiC layer stimulates adhesion, proliferation and activity of osteoblasts. • Uncoated and TiC coated titanium implants were implanted in rabbit femurs. • Bone-implant contacts of TiC coated implants were higher than that of uncoated. • Mineral Apposition Rate of TiC coated implants were higher than that of uncoated.

  6. Osseointegration is improved by coating titanium implants with a nanostructured thin film with titanium carbide and titanium oxides clustered around graphitic carbon

    International Nuclear Information System (INIS)

    Veronesi, Francesca; Giavaresi, Gianluca; Fini, Milena; Longo, Giovanni; Ioannidu, Caterina Alexandra; Scotto d'Abusco, Anna; Superti, Fabiana; Panzini, Gianluca; Misiano, Carlo; Palattella, Alberto; Selleri, Paolo; Di Girolamo, Nicola; Garbarino, Viola; Politi, Laura; Scandurra, Roberto

    2017-01-01

    Titanium implants coated with a 500 nm nanostructured layer, deposited by the Ion Plating Plasma Assisted (IPPA) technology, composed of 60% graphitic carbon, 25% titanium oxides and 15% titanium carbide were implanted into rabbit femurs whilst into the controlateral femurs uncoated titanium implants were inserted as control. At four time points the animals were injected with calcein green, xylenol orange, oxytetracycline and alizarin. After 2, 4 and 8 weeks femurs were removed and processed for histology and static and dynamic histomorphometry for undecalcified bone processing into methylmethacrylate, sectioned, thinned, polished and stained with Toluidine blue and Fast green. The overall bone-implant contacts rate (percentage of bone-implant contacts/weeks) of the TiC coated implant was 1.6 fold than that of the uncoated titanium implant. The histomorphometric analyses confirmed the histological evaluations. More precisely, higher Mineral Apposition Rate (MAR, μm/day) (p < 0.005) and Bone Formation Rate (BFR, μm 2 /μm/day) (p < 0.0005) as well as Bone Implant Contact (Bic) and Bone Ingrowth values (p < 0.0005) were observed for the TiC coated implants compared to uncoated implants. In conclusion the hard nanostructured TiC layer protects the bulk titanium implant against the harsh conditions of biological tissues and in the same time, stimulating adhesion, proliferation and activity of osteoblasts, induces a better bone-implant contacts of the implant compared to the uncoated titanium implant. - Highlights: • Ti implants were coated with a nanostructured film composed of C gr , TiC and TiO x . • The TiC layer stimulates adhesion, proliferation and activity of osteoblasts. • Uncoated and TiC coated titanium implants were implanted in rabbit femurs. • Bone-implant contacts of TiC coated implants were higher than that of uncoated. • Mineral Apposition Rate of TiC coated implants were higher than that of uncoated.

  7. Nickel-titanium alloys: a systematic review

    Directory of Open Access Journals (Sweden)

    Marcelo do Amaral Ferreira

    2012-06-01

    Full Text Available OBJECTIVE: A systematic review on nickel-titanium wires was performed. The strategy was focused on Entrez-PubMed-OLDMEDLINE, Scopus and BioMed Central from 1963 to 2008. METHODS: Papers in English and French describing the behavior of these wires and laboratorial methods to identify crystalline transformation were considered. A total of 29 papers were selected. RESULTS: Nickel-titanium wires show exceptional features in terms of elasticity and shape memory effects. However, clinical applications request a deeper knowledge of these properties in order to allow the professional to use them in a rational manner. In addition, the necessary information regarding each alloy often does not correspond to the information given by the manufacturer. Many alloys called "superelastic" do not present this effect; they just behave as less stiff alloys, with a larger springback if compared to the stainless steel wires. CONCLUSIONS: Laboratory tests are the only means to observe the real behavior of these materials, including temperature transition range (TTR and applied tensions. However, it is also possible to determine in which TTR these alloys change the crystalline structure.

  8. Ballistic Limit Equation for Single Wall Titanium

    Science.gov (United States)

    Ratliff, J. M.; Christiansen, Eric L.; Bryant, C.

    2009-01-01

    Hypervelocity impact tests and hydrocode simulations were used to determine the ballistic limit equation (BLE) for perforation of a titanium wall, as a function of wall thickness. Two titanium alloys were considered, and separate BLEs were derived for each. Tested wall thicknesses ranged from 0.5mm to 2.0mm. The single-wall damage equation of Cour-Palais [ref. 1] was used to analyze the Ti wall's shielding effectiveness. It was concluded that the Cour-Palais single-wall equation produced a non-conservative prediction of the ballistic limit for the Ti shield. The inaccurate prediction was not a particularly surprising result; the Cour-Palais single-wall BLE contains shield material properties as parameters, but it was formulated only from tests of different aluminum alloys. Single-wall Ti shield tests were run (thicknesses of 2.0 mm, 1.5 mm, 1.0 mm, and 0.5 mm) on Ti 15-3-3-3 material custom cut from rod stock. Hypervelocity impact (HVI) tests were used to establish the failure threshold empirically, using the additional constraint that the damage scales with impact energy, as was indicated by hydrocode simulations. The criterion for shield failure was defined as no detached spall from the shield back surface during HVI. Based on the test results, which confirmed an approximately energy-dependent shield effectiveness, the Cour-Palais equation was modified.

  9. Atomic absorption analysis of serial titanium alloys

    International Nuclear Information System (INIS)

    Gorlova, M.N.; Feofanova, N.M.; Kornyushkova, Yu.D.

    1977-01-01

    Atom-absorption technique is described, which makes it possible to rapidly and precisely determine the following alloying elements and admixtures in titanium alloys: Al (2.0 - 8.5%); Mo (0.5 - 8%); Cr (0.5 - 12%); Si (0.2 - 0.5%); Mn(0.2 - 2.5%); V(0.5 - 6%); Sn(2.0 - 3.0%); Fe(0.1 - 1.0%); Zr(2.0 - 12.0%). The atom absorption method with flame atomization of the sample provides for best results if the alloy is dissolved in a mixture HCl + HBF 4 in the ratio 2:1. In order to obtain correct results the standard solutions must contain titanium in concentrations corresponding to the weight of the sample being analyzed. Sensitivity of zirconium determination may be increased approximately twofold by adding 10 mg/ml of FeCl 3 into the solution. Being as precise, as the classic analytical methods, the atom absorption technique is about 5 times more efficient

  10. Synthesis of titanium sapphire by ion implantation

    International Nuclear Information System (INIS)

    Morpeth, L.D.; McCallum, J.C.; Nugent, K.W.

    1998-01-01

    Since laser action was first demonstrated in titanium sapphire (Ti:Al 2 O 3 ) in 1982, it has become the most widely used tunable solid state laser source. The development of a titanium sapphire laser in a waveguide geometry would yield an elegant, compact, versatile and highly tunable light source useful for applications in many areas including optical telecommunications. We are investigating whether ion implantation techniques can be utilised to produce suitable crystal quality and waveguide geometry for fabrication of a Ti:Al 2 O 3 waveguide laser. The implantation of Ti and O ions into c-axis oriented α-Al 2 O 3 followed by subsequent thermal annealing under various conditions has been investigated as a means of forming the waveguide and optimising the fraction of Ti ions that have the correct oxidation state required for laser operation. A Raman Microprobe is being used to investigate the photo-luminescence associated with Ti 3+ ion. Initial photoluminescence measurements of ion implanted samples are encouraging and reveal a broad luminescence profile over a range of ∼ .6 to .9 μm, similar to that expected from Ti 3+ . Rutherford Backscattering and Ion Channelling analysis have been used to study the crystal structure of the samples following implantation and annealing. This enables optimisation of the implantation parameters and annealing conditions to minimise defect levels which would otherwise limit the ability of light to propagate in the Ti:Al 2O 3 waveguide. (authors)

  11. Additive Manufacturing of Metastable Beta Titanium Alloys

    Science.gov (United States)

    Yannetta, Christopher J.

    Additive manufacturing processes of many alloys are known to develop texture during the deposition process due to the rapid reheating and the directionality of the dissipation of heat. Titanium alloys and with respect to this study beta titanium alloys are especially susceptible to these effects. This work examines Ti-20wt%V and Ti-12wt%Mo deposited under normal additive manufacturing process parameters to examine the texture of these beta-stabilized alloys. Both microstructures contained columnar prior beta grains 1-2 mm in length beginning at the substrate with no visible equiaxed grains. This microstructure remained constant in the vanadium system throughout the build. The microstructure of the alloy containing molybdenum changed from a columnar to an equiaxed structure as the build height increased. Eighteen additional samples of the Ti-Mo system were created under different processing parameters to identify what role laser power and travel speed have on the microstructure. There appears to be a correlation in alpha lath size and power density. The two binary alloys were again deposited under the same conditions with the addition of 0.5wt% boron to investigate the effects an insoluble interstitial alloying element would have on the microstructure. The size of the prior beta grains in these two alloys were reduced with the addition of boron by approximately 50 (V) and 100 (Mo) times.

  12. Characterizations of additive manufactured porous titanium implants.

    Science.gov (United States)

    Basalah, Ahmad; Shanjani, Yaser; Esmaeili, Shahrzad; Toyserkani, Ehsan

    2012-10-01

    This article describes physical, chemical, and mechanical characterizations of porous titanium implants made by an additive manufacturing method to gain insight into the correlation of process parameters and final physical properties of implants used in orthopedics. For the manufacturing chain, the powder metallurgy technology was combined with the additive manufacturing to fabricate the porous structure from the pure tanium powder. A 3D printing machine was employed in this study to produce porous bar samples. A number of physical parameters such as titanium powder size, polyvinyl alcohol (PVA) amount, sintering temperature and time were investigated to control the mechanical properties and porosity of the structures. The produced samples were characterized through porosity and shrinkage measurements, mechanical compression test and scanning electron microscopy (SEM). The results showed a level of porosity in the samples in the range of 31-43%, which is within the range of the porosity of the cancelluous bone and approaches the range of the porosity of the cortical bone. The results of the mechanical test showed that the compressive strength is in the wide range of 56-509 MPa implying the effect of the process parameters on the mechanical strengths. This technique of manufacturing of Ti porous structures demonstrated a low level of shrinkage with the shrinkage percentage ranging from 1.5 to 5%. Copyright © 2012 Wiley Periodicals, Inc.

  13. Structure of titanium-doped goethite rust

    International Nuclear Information System (INIS)

    Nakayama, Takenori; Ishikawa, Tatsuo; Konno, Toyohiko J.

    2005-01-01

    To investigate the influence of titanium addition on the formation and structure of goethite (α-FeOOH) rust which is one of main corrosion products of weathering steel, the artificially synthesized α-FeOOH rusts were prepared by hydrolysis of aqueous solutions of Fe(III) containing Ti(IV) at different atomic ratios (Ti/Fe) in the range 0-0.1. The obtained rusts particles were observed by TEM. Characterization by XRD, N 2 absorption, Moessbauer spectroscopy was also done. TEM observation revealed that the α-FeOOH rust particle size increased with the increase of Ti/Fe, and that Ti-enriched poorly crystalline particles were formed around the rust particles. XRD confirmed that the crystallite size increased with the increase of Ti/Fe, while the XRD peaks decreased in intensity. Specific surface area obtained by N 2 absorption increased with the increase of Ti/Fe. It is deduced from the obtained results that the addition of Ti(IV) increases the crystallite size of α-FeOOH, and produces double domain particles consisting of the particle core and a porous poorly crystalline shell. It is thought that such unique rust structure produced by titanium addition contributes to the protective properties of rust layer of the weathering steel

  14. Nanomaterial Case Studies: Nanoscale Titanium Dioxide in ...

    Science.gov (United States)

    EPA announced the availability of the final report, Nanomaterial Case Studies: Nanoscale Titanium Dioxide in Water Treatment and in Topical Sunscreen. This report is a starting point to determine what is known and what needs to be known about selected nanomaterials as part of a process to identify and prioritize research to inform future assessments of the potential ecological and health implications of these materials. Two specific applications of nanoscale titanium dioxide (nano-TiO2) are considered: (1) as an agent for removing arsenic from drinking water; and (2) as an active ingredient in topical sunscreen. These case studies are organized around a comprehensive environmental assessment (CEA) framework that combines a product life cycle perspective with the risk assessment paradigm. They are intended to help identify what may need to be known in order to conduct a comprehensive environmental assessment of the potential risks related to nano-TiO2. These “case studies” do not represent completed or even preliminary assessments, nor are they intended to serve as a basis for risk management decisions in the near term on these specific uses of nano TiO2. Rather, the intent is to use this document in developing the scientific and technical information needed for future assessment efforts.

  15. Molecular and physiological responses to titanium dioxide ...

    Science.gov (United States)

    - Changes in tissue transcriptomes and productivity of Arabidopsis thaliana were investigated during exposure of plants to two widely-used engineered metal oxide nanoparticles, titanium dioxide (nano-titanium) and cerium dioxide (nano-cerium). Microarray analyses confirmed that exposure to either nanoparticle altered the transcriptomes of rosette leaves and roots, with comparatively larger numbers of differentially expressed genes (DEGs) found under nano-titania exposure. Nano-titania induced more DEGs in rosette leaves, whereas roots had more DEGs under nano-ceria exposure. MapMan analyses indicated that while nano-titania up-regulated overall and secondary metabolism in both tissues, metabolic processes under nano-ceria remained mostly unchanged. Gene enrichment analysis indicated that both nanoparticles mainly enriched ontology groups such as responses to stress (abiotic and biotic), and defense responses (pathogens), and responses to endogenous stimuli (hormones). Nano-titania specifically induced genes associated with photosynthesis, whereas nano-ceria induced expression of genes related to activating transcription factors, most notably those belonging to the ethylene responsive element binding protein family. Interestingly, there were also increased numbers of rosette leaves and plant biomass under nano-ceria exposure, but not under nano-titania. Other transcriptomic responses did not clearly relate to responses observed at the organism level. This may b

  16. Enhancement of catalyst performance in the direct propene epoxidation: a study into gold-titanium synergy

    NARCIS (Netherlands)

    Chen, J.; Halin, S.J.A.; Pidko, E.A.; Verhoeven, M.W.G.M.; Perez Ferrandez, D.M.; Hensen, E.J.M.; Schouten, J.C.; Nijhuis, T.A.

    2013-01-01

    Enhanced productivity toward propene oxide in the direct propene epoxidation with hydrogen and oxygen over gold nanoparticles supported on titanium-grafted silica was achieved by adjusting the gold–titanium synergy. Highly isolated titanium sites were obtained by lowering the titanium loading

  17. Experimental Technique of Titanium Fire in Aero-engine

    Directory of Open Access Journals (Sweden)

    MI Guangbao

    2016-06-01

    Full Text Available Titanium fire is the typical catastrophic fault in the aero-engine. Aiming at the urgent demand for experimental technique of titanium fire from advanced high thrust-weight ratio aero-engine, the combustion technology and theory of titanium alloy based on friction oxygen concentration method (FOC were systematically studied. The evaluation method of fireproof property and the friction ignition model were built, and the fireproof mechanism was illustrated. By generalizing recent progress in experimental technique of titanium fire from three levels, including evolutionary rule, mechanism and prevention and control technology, the ideas and directions of experimental technique associated with the application research of titanium fire in the future were proposed, namely overall evaluation of fireproof property close to air flow environment of the aero-engine, prediction model of fireproof property and experimental verification of fireproof technique under the air flow environment of aero-engine. It is necessary to establish the prevention system of titanium fire in aero-engine, which contributes to the realization of "full titanium" in compressor and to the increase of high thrust-weight ratio.

  18. Hydrogen embrittlement of titanium tested with fracture mechanics specimens

    International Nuclear Information System (INIS)

    Aho-Mantila, I.; Rahko, P.

    1990-11-01

    Titanium is one of the possible canister materials for spent nuclear fuel. The aim of this study is to determine whether the hydrogen embrittlement of titanium could be a possible deterioration mechanism of titanium canisters. This experimental study was preceded by a literature review and an experimental study on crack nucleation. Tests in this study were carried out with hydrogen charged fracture mechanics specimens. The studied hydrogen contents were as received, 100 ppm, 200 ppm, 500 ppm and 700 ppm and the types of the studied titanium were ASTM Grades 2 and 12. Test methods were slow tensile test (0.027 mm/h) and fatigue test (stress ratio 0.7 or 0.8 and frequency 5 Hz). According to the literature titanium may be embrittled by hydrogen at slow strain rates and cracking may occur under sustained load. In this study no evidence of hydrogen embrittlement was noticed in slow strain rate tension with bulk hydrogen contents up to 700 ppm. The fatigue tests of titanium Grades 2 and 12 containing 700 ppm hydrogen showed even slower crack growth compared to the as received condition. Very high hydrogen contents well in eccess of 700 ppm on the surface of titanium can, however, facilitate surface crack nucleation and crack growth, as shown in the previous study

  19. All welded titanium condenser adopted in atomic power plants

    International Nuclear Information System (INIS)

    Iwai, Nagao; Itabashi, Yukihiko

    1980-01-01

    Condensers in power plants are shell-and-tube type heat exchangers. Most condensers use seawater as a coolant. Their tube and tube Sheets have usually been made of brass, which resists corrosion but cannot completely prevent it; as a result, tubes sometimes corrode or erode, allowing seawater to leak into the turbine cycle. As is well known, titanium has almost complete corrosion resistance against seawater; for this reason titanium tubes have replaced brass ones in some condensers operating in Europe and the USA. Even in such condensers, though, the tube plates have still been made of brass, tightly fitted to the titanium tubes, and it has proved impossible to eliminate seawater leakage at the junctions between tubes and tube Sheets. In order to eliminate such leakage completely, the tube Sheets must be made of titanium too, and the tubes and plates must be welded together. However, the welding of titanium requires an extremely celan atmosphere, a condition very difficult to fulfill at power plant construction sites, and the use of whole welded titanium tube condensers has long been considered a practical impossibility. Such all-titanium welded condensers have now been successfully constructed and installed in two 600 MW fossil power plants and one 1100 MW nuclear power plant. This paper describes the techniques used, add in addition reviews the various materials that have been used in condenser tubes. (author)

  20. Laser shock peening of titanium 6-4 alloy

    International Nuclear Information System (INIS)

    Brar, N.S.; Hopkins, A.; Laber, M.W.

    2000-01-01

    Laser shock peening of titanium 6-4 has been shown to improve its high cycle fatigue life. Residual compressive stresses generated on the surface of titanium 6-4, as a result of laser shocking, have shown dramatic improvement in the performance of aircraft turbine blades. Laser shocking of titanium was carried out with a 20 ns pulse width, 50 joule pulsed laser, operated by LSP Technologies, Columbus, OH. Titanium disks, 20-mm in diameter, and ranging in thicknesses from zero (bare LiF) to 3-mm were subjected to laser shock to monitor amplitude and temporal stress profiles of the pulsed laser. Laser shock stress amplitudes on the back of titanium disks were monitored with VISAR using LiF as the window material. The peak shock stress produced in LiF (titanium thickness zero) was measured to be 16±1 GPa. The laser shock amplitude decays to about 2.7 GPa while propagating through 3-mm thick disk of titanium 6-4

  1. Effect of cathodic polarization on coating doxycycline on titanium surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Geißler, Sebastian; Tiainen, Hanna; Haugen, Håvard J., E-mail: h.j.haugen@odont.uio.no

    2016-06-01

    Cathodic polarization has been reported to enhance the ability of titanium based implant materials to interact with biomolecules by forming titanium hydride at the outermost surface layer. Although this hydride layer has recently been suggested to allow the immobilization of the broad spectrum antibiotic doxycycline on titanium surfaces, the involvement of hydride in binding the biomolecule onto titanium remains poorly understood. To gain better understanding of the influence this immobilization process has on titanium surfaces, mirror-polished commercially pure titanium surfaces were cathodically polarized in the presence of doxycycline and the modified surfaces were thoroughly characterized using atomic force microscopy, electron microscopy, secondary ion mass spectrometry, and angle-resolved X-ray spectroscopy. We demonstrated that no hydride was created during the polarization process. Doxycycline was found to be attached to an oxide layer that was modified during the electrochemical process. A bacterial assay using bioluminescent Staphylococcus epidermidis Xen43 showed the ability of the coating to reduce bacterial colonization and planktonic bacterial growth. - Highlights: • Titanium hydride was found not to be involved in immobilization of doxycycline. • Doxycycline coating was strongly bound to a modified surface oxide layer. • Effect of coatings tested using a dynamic bacteria assay based on bioluminescence. • Topmost layer of adsorbed doxycycline was shown to have strong antibacterial effect.

  2. Surface Functionalization of Orthopedic Titanium Implants with Bone Sialoprotein.

    Directory of Open Access Journals (Sweden)

    Andreas Baranowski

    Full Text Available Orthopedic implant failure due to aseptic loosening and mechanical instability remains a major problem in total joint replacement. Improving osseointegration at the bone-implant interface may reduce micromotion and loosening. Bone sialoprotein (BSP has been shown to enhance bone formation when coated onto titanium femoral implants and in rat calvarial defect models. However, the most appropriate method of BSP coating, the necessary level of BSP coating, and the effect of BSP coating on cell behavior remain largely unknown. In this study, BSP was covalently coupled to titanium surfaces via an aminosilane linker (APTES, and its properties were compared to BSP applied to titanium via physisorption and untreated titanium. Cell functions were examined using primary human osteoblasts (hOBs and L929 mouse fibroblasts. Gene expression of specific bone turnover markers at the RNA level was detected at different intervals. Cell adhesion to titanium surfaces treated with BSP via physisorption was not significantly different from that of untreated titanium at any time point, whereas BSP application via covalent coupling caused reduced cell adhesion during the first few hours in culture. Cell migration was increased on titanium disks that were treated with higher concentrations of BSP solution, independent of the coating method. During the early phases of hOB proliferation, a suppressive effect of BSP was observed independent of its concentration, particularly when BSP was applied to the titanium surface via physisorption. Although alkaline phosphatase activity was reduced in the BSP-coated titanium groups after 4 days in culture, increased calcium deposition was observed after 21 days. In particular, the gene expression level of RUNX2 was upregulated by BSP. The increase in calcium deposition and the stimulation of cell differentiation induced by BSP highlight its potential as a surface modifier that could enhance the osseointegration of orthopedic implants

  3. Laser beam welding of titanium nitride coated titanium using pulse-shaping

    Directory of Open Access Journals (Sweden)

    Milton Sergio Fernandes de Lima

    2005-09-01

    Full Text Available A new welding method which allows the assembly of two titanium nitride coated titanium parts is proposed. The welding procedure utilizes the possibility for pulse-shaping in order to change the energy distribution profile during the laser pulse. The pulse-shaping is composed of three elements: a a short high power pulse for partial ablation at the surface; b a long pulse for thermal penetration; and c a quenching slope for enhanced weldability. The combination of these three elements produces crack-free welds. The weld microstructure is changed in comparison to normal welding, i.e. with a rectangular pulse, as the nitrogen and the microhardness are more homogenously distributed in the weld under pulse-shaping conditions. This laser pulse dissolves the TiN layer and allows nitrogen to diffuse into the melt pool, also contributing to an enhanced weldability by providing suitable thermal conditions.

  4. Inhibitor effect on corrosion of titanium alloys in muriatic solutions of titanium-magnesium production

    International Nuclear Information System (INIS)

    Dobrunov, Yu.V.; Volynskij, V.V.; Kolobov, G.A.; Kuznetsov, S.I.

    1977-01-01

    Corrosion tests of titanium alloys VTI-0, OT4, VT5-1 and steel Kh18N1OT in 10% and 18% HCl with additions of carnallite at 40 deg C have been carried out. It has been established that titanium alloys in 10% and 18% HCl containing 5 and 10% carnallite are sufficiently corrosion resistant in the presence of 0.1-1% FeCl or HNO 3 and can be used for manufacturing the equipment of recirculation gas scrubbers. Steel Kh18N10T is unstable in all the media tested. It is subjected to intensive pitting. Specimens of steel Kh18N10T have also revealed edge cracking

  5. Narrow titanium oxide nanowires induced by femtosecond laser pulses on a titanium surface

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hui; Li, Xian-Feng [Laboratory of Nanophotonic Functional Materials and Devices, School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006 (China); Zhang, Cheng-Yun [School of Physics and Electronic Engineering, Guangzhou University, Guangzhou 510006 (China); Tie, Shao-Long [School of Chemistry and Environment, South China Normal University, Guangzhou 510006 (China); Lan, Sheng, E-mail: slan@scnu.edu.cn [Laboratory of Nanophotonic Functional Materials and Devices, School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006 (China)

    2017-02-28

    Highlights: • Titanium oxide nanowires with a feature width as narrow as ∼20 nm were induced on a titanium surface by using femtosecond laser pulses at 400 nm. • An evolution of the surface structure from a high spatial frequency laser-induced periodic structure parallel to the laser polarization to a low spatial frequency one perpendicular to the laser polarization was observed with increasing irradiation pulse number. • The formation of the titanium oxide nanowires was confirmed by the energy dispersive spectroscopy measurements and the evolution of the surface structure was successfully interpreted by using the efficacy factor theory. - Abstract: The evolution of the nanostructure induced on a titanium (Ti) surface with increasing irradiation pulse number by using a 400-nm femtosecond laser was examined by using scanning electron microscopy. High spatial frequency periodic structures of TiO{sub 2} parallel to the laser polarization were initially observed because of the laser-induced oxidation of the Ti surface and the larger efficacy factor of TiO{sub 2} in this direction. Periodically aligned TiO{sub 2} nanowires with featured width as small as 20 nm were obtained. With increasing pulse number, however, low spatial frequency periodic structures of Ti perpendicular to the laser polarization became dominant because Ti possesses a larger efficacy factor in this direction. The competition between the high- and low-spatial frequency periodic structures is in good agreement with the prediction of the efficacy factor theory and it should also be observed in the femtosecond laser ablation of other metals which are easily oxidized in air.

  6. Nonmetal effect on ordering structures in titanium carbide

    International Nuclear Information System (INIS)

    Tashmetov, M.Yu.; Ehm, V.T.; Savenko, B.M.

    1997-01-01

    The effect of oxygen and nitrogen atoms on formation of intermediate, cubic and trigonal ordering structures in the titanium carbide is studied through the roentgenography and neutron radiography methods. Metal atoms in the TiC 0.545 O 0.08 , TiC 0.545 N 0.09 samples under study are shifted from ideal positions in the direction from vacancies to metalloid atoms. In the intermediate cubic phase the values of the titanium atoms free parameter in both samples are identical, but they differ from analogous values in the titanium carbide

  7. Colloidal Plasmonic Titanium Nitride Nanoparticles: Properties and Applications

    Directory of Open Access Journals (Sweden)

    Guler Urcan

    2015-01-01

    Full Text Available Optical properties of colloidal plasmonic titanium nitride nanoparticles are examined with an eye on their photothermal and photocatalytic applications via transmission electron microscopy and optical transmittance measurements. Single crystal titanium nitride cubic nanoparticles with an average size of 50 nm, which was found to be the optimum size for cellular uptake with gold nanoparticles [1], exhibit plasmon resonance in the biological transparency window and demonstrate a high absorption efficiency. A self-passivating native oxide at the surface of the nanoparticles provides an additional degree of freedom for surface functionalization. The titanium oxide shell surrounding the plasmonic core can create new opportunities for photocatalytic applications.

  8. Models for the adsorption of uranium on titanium dioxide

    International Nuclear Information System (INIS)

    Jaffrezic-Renault, N.; Poirier-Andrade, H.; Trang, D.H.

    1980-01-01

    A hydrated titanium oxide whose acid-base properties are well defined has been used to study the retention mechanism of uranium as UO 2 2+ (in acidic media) and as UO 2 (CO 3 ) 3 4- (in carbonate media). The influence of various parameters on the distribution coefficient of uranium (pH, [CO 3 2- ]) and of the adsorption of uranium on the electrophoretic mobilities of the titanium oxide have been investigated. It is shown that, in both media, coordinative TiO-UO 2 bonds are formed. These strong bonds explain the high affinity of the titanium oxide for uranium. (orig.)

  9. The use of titanium and stainless steel in fracture fixation.

    Science.gov (United States)

    Hayes, J S; Richards, R G

    2010-11-01

    The use of metal in fracture fixation has demonstrated unrivalled success for many years owing to its high stiffness, strength, biological toleration and overall reliable function. The most prominent materials used are electropolished stainless steel and commercially pure titanium, along with the more recent emergence of titanium alloys. Despite the many differences between electropolished stainless steel and titanium, both materials provide a relatively predictable clinical outcome, and offer similar success for fulfilling the main biomechanical and biological requirements of fracture fixation despite distinctive differences in implant properties and biological responses. This article explores these differences by highlighting the limitations and advantages of both materials, and addresses how this translates to clinical success.

  10. Water leaching of titanium from ore flotation residue.

    Science.gov (United States)

    Jaworska, Malgorzata M; Guibal, Eric

    2003-01-01

    Copper ore tailings were tested for the stability of titanium submitted to water leaching in three different reactor systems (agitated vessel, bioreactor and percolated fixed-bed column). For each of these systems, titanium extraction did not exceed 1% of the available metal. Biomass removed from ore residue adsorbed a small part of the titanium with sorption capacities below 20-30 mg g(-1), but most of this biomass was sequestered in the ore residue. Oxygen and carbon dioxide concentrations were monitored and changes in concentration correlated with bacteria development at the initial stage of the process and to fungal development in the latter stages.

  11. Vanadium and titanium determination by resorcinalhydrazide of salicylic acid

    Energy Technology Data Exchange (ETDEWEB)

    Karpova, O I; Pilipenko, A T; Lukachina, V V [AN Ukrainskoj SSR, Kiev. Inst. Kolloidnoj Khimii i Khimii Vody

    1979-02-01

    The complexing of titanium and vanadium with resorcinalhydrazyl of salicylic acid (RHSA) in water-organic media is studied. Titanium (4) forms a complex at pH 0.8-1.8, vanadium - at pH 2.5-5.6, and at pH 7.6-9.8. The complexes are well extracted by polar and nonpolar solvents from acid solutions. The techniques are developed for the determination of titanium and vanadium by the RHSA agent in nickel alloys.

  12. Characterization and Sintering of Armstrong Process Titanium Powder

    Science.gov (United States)

    Xu, Xiaoyan; Nash, Philip; Mangabhai, Damien

    2017-04-01

    Titanium and titanium alloys have a high strength to weight ratio and good corrosion resistance but also need longer time and have a higher cost on machining. Powder metallurgy offers a viable approach to produce near net-shape complex components with little or no machining. The Armstrong titanium powders are produced by direct reduction of TiCl4 vapor with liquid sodium, a process which has a relatively low cost. This paper presents a systematic research on powder characterization, mechanical properties, and sintering behavior and of Armstrong process powder metallurgy, and also discusses the sodium issue, and the advantages and disadvantages of Armstrong process powders.

  13. Interaction of titanium and vanadium with carbon dioxide under heating

    International Nuclear Information System (INIS)

    Vlasyuk, R.Z.; Kurovskij, V.Ya.; Lyapunov, V.P.; Radomysel'skij, I.D.

    1986-01-01

    The methods of gravitmetric and X-ray phase analysis as well as analysis of composition of gases in the heating chamber have been used to investigate the mechanism of titanium and vanadium interaction with carbon dioxide in the 300-1000 deg C temperature range. The analogy of mechanisms of the interaction of titanium and vanadium with carbon dioxide in oxides production on the metal surface with subsequent carbidizing treatment at temperatures above 800 deg C is shown. Temperature limits of material operation on the base of titanium or vanadium in carbon dioxide must not exceed 400 or 600 deg C, respectively

  14. Muscle activity during endotracheal intubation using 4 laryngoscopes (Macintosh laryngoscope, Intubrite, TruView Evo2 and King Vision – A comparative study

    Directory of Open Access Journals (Sweden)

    Tomasz Gaszyński

    2016-04-01

    Full Text Available Background: Successful endotracheal intubation requires mental activity and no less important physical activity from the anesthesiologist, so ergonomics of used devices is important. The aim of our study has been to compare 4 laryngoscopes regarding an operator’s activity of selected muscles of the upper limb, an operator’s satisfaction with used devices and an operator’s fatigue during intubation attempts. Material and Methods: The study included 13 anesthesiologists of similar seniority. To measure muscle activity MyoPlus 2 with 2-channel surface ElectroMyoGraphy (sEMG test device was used. Participant’s satisfaction with studied devices was evaluated using Visual Analog Scale. An operator’s fatigue during intubation efforts was evaluated by means of the modified Borg’s scale. Results: The highest activity of all the studied muscles was observed for the Intubrite laryngoscope, followed by the Mackintosh, TruView Evo2 and the lowest one – for the King Vision video laryngoscope. A significant statistical difference was observed for the King Vision and the rest of laryngoscopes (p 0.05. The shortest time of intubation was achieved using the standard Macintosh blade laryngoscope. The highest satisfaction was noted for the King Vision video laryngoscope, and the lowest for – the TruView Evo2. The Intubrite was the most demanding in terms of workload, in the opinion of the participants’, and the least demanding was the King Vision video laryngoscope. Conclusions: Muscle activity, namely the force used for intubation, is the smallest when the King Vision video laryngoscope is used with the highest satisfaction and lowest workload, and the highest muscle activity was proven for the Intubrite laryngoscope with the highest workload. Med Pr 2016;67(2:155–162

  15. Evaluation of performance of Streamlined Liner of the Pharynx Airway™, Laryngeal Mask Airway-ProSeal and endotracheal tube in prone position: A prospective, randomised study

    Directory of Open Access Journals (Sweden)

    Harihar Vishwanath Hegde

    2018-01-01

    Full Text Available Background and Aims: Airway used in prone position should be efficacious and safe. The Streamlined Liner of the Pharynx Airway (SLIPA™ and Laryngeal Mask Airway-ProSeal (PLMA provide better airway seal and protection against aspiration. We planned to evaluate the performance of SLIPA™, PLMA and endotracheal tube (ETT in prone position. Methods: 114 adult patients undergoing elective surgery in prone position under general anaesthesia were randomised into Group-T (ETT, Group-S (SLIPA™ and Group-P (PLMA. Airways were inserted in supine position and patients turned prone subsequently. Airway characteristics, ventilatory parameters and complications were noted. One-way analysis of variance, Mann–Whitney U-test and Chi-square or Fisher's exact test were used. Results: Tidal volumes, peak airway pressure and compliance were comparable at all times. Leak pressure was significantly higher (P < 0.001 in Group-T (mean leak pressure = 40 cmH2O when compared to Group-S and Group-P at all the times of recording, and there was no significant difference between Group-S and Group-P. The number of patients requiring airway/neck manipulation in prone position was significantly higher (P < 0.001 in Group-S (19 [55.9%] when the three groups were compared (none in Group-T and in comparison with Group-P (5 [14.7%], P < 0.001. On airway removal, the incidence of complications and airway reaction was significantly higher in Group-T. Group-S had a significantly higher incidence of dysphagia at 2 h postoperatively. Conclusion: ETT was most efficacious. SLIPA™ and PLMA were efficacious, safe and less stimulating to the airway during removal. More patients required SLIPA™ airway/neck manipulation.

  16. ProSeal laryngeal mask airway as an alternative to standard endotracheal tube in securing upper airway in the patients undergoing beating-heart coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Kalpana Shah

    2017-01-01

    Full Text Available Background: ProSeal laryngeal mask airways (PLMAs are routinely used after failed tracheal intubation as airway rescue, facilitating tracheal intubation by acting as a conduit and to secure airway during emergencies. In long duration surgeries, use of endotracheal tube (ETT is associated with various hemodynamic complications, which are minimally affected during PLMA use. However, except for few studies, there are no significant data available that promote the use of laryngeal mask during cardiac surgery. This prospective study was conducted with the objective of demonstrating the advantages of PLMA over ETT in the patients undergoing beating-heart coronary artery bypass graft (CABG. Methodology: This prospective, interventional study was carried out in 200 patients who underwent beating-heart CABG. Patients were randomized in equal numbers to either ETT group or PLMA group, and various hemodynamic and respiratory parameters were observed at different time points. Results: Patients in PLMA group had mean systolic blood pressure 126.10 ± 5.31 mmHg compared to the patients of ETT group 143.75 ± 6.02 mmHg. Pulse rate in the PLMA group was less (74.52 ± 10.79 per min (P < 0.05 compared to ETT group (81.72 ± 9.8. Thus, hemodynamic changes were significantly lower (P < 0.05 in PLMA than in ETT group. Respiratory parameters such as oxygen saturation, pressure CO 2 (pCO 2 , peak airway pressure, and lung compliance were similar to ETT group at all evaluation times. The incidence of adverse events was also lower in PLMA group. Conclusion: In experience hand, PLMA offers advantages over the ETT in airway management in the patients undergoing beating-heart CABG.

  17. The impact of hospital-wide use of a tapered-cuff endotracheal tube on the incidence of ventilator-associated pneumonia.

    Science.gov (United States)

    Bowton, David L; Hite, R Duncan; Martin, R Shayn; Sherertz, Robert

    2013-10-01

    Aspiration of colonized oropharyngeal secretions is a major factor in the pathogenesis of ventilator-associated pneumonia (VAP). A tapered-cuff endotracheal tube (ETT) has been demonstrated to reduce aspiration around the cuff. Whether these properties are efficacious in reducing VAP is not known. This 2-period, investigator-initiated observational study was designed to assess the efficacy of a tapered-cuff ETT to reduce the VAP rate. All intubated, mechanically ventilated patients over the age of 18 were included. During the baseline period a standard, barrel-shaped-cuff ETT (Mallinckrodt Hi-Lo) was used. All ETTs throughout the hospital were then replaced with a tapered-cuff ETT (TaperGuard). The primary outcome variable was the incidence of VAP per 1,000 ventilator days. We included 2,849 subjects, encompassing 15,250 ventilator days. The mean ± SD monthly VAP rate was 3.29 ± 1.79/1,000 ventilator days in the standard-cuff group and 2.77 ± 2.00/1,000 ventilator days in the tapered-cuff group (P = .65). While adherence to the VAP prevention bundle was high throughout the study, bundle adherence was significantly higher during the standard-cuff period (96.5 ± 2.7%) than in the tapered-cuff period (90.3 ± 3.5%, P = .01). In the setting of a VAP rate very near the average of ICUs in the United States, and where there was high adherence to a VAP prevention bundle, the use of a tapered-cuff ETT was not associated with a reduction in the VAP rate.

  18. Tidal Volume Delivery and Endotracheal Tube Leak during Cardiopulmonary Resuscitation in Intubated Newborn Piglets with Hypoxic Cardiac Arrest Exposed to Different Modes of Ventilatory Support.

    Science.gov (United States)

    Mendler, Marc R; Weber, Claudia; Hassan, Mohammad A; Huang, Li; Mayer, Benjamin; Hummler, Helmut D

    2017-01-01

    There are few data available on the interaction of inflations, chest compressions (CC), and delivery of tidal volumes in newborn infants undergoing resuscitation in the presence of endotracheal tube (ET) leaks. To determine the effects of different respiratory support strategies along with CC on changes in tidal volume and ET leaks in hypoxic newborn piglets with cardiac arrest. Asphyxiated newborn piglets, intubated with weight-adapted uncuffed ET, were randomized into three groups and resuscitated according to ILCOR 2010 guidelines: (1) T-piece resuscitator (TPR) group = peak inspiratory pressure (PIP)/positive end-expiratory pressure (PEEP) 25/5 cm H2O, rate 30/min, inflations interposed between CC (3:1 ratio); (2) self- inflating bag (SIB) group = PIP 25 cm H2O without PEEP, rate 30/min, inflations interposed between CC (3:1 ratio), and (3) ventilator group = PIP/PEEP of 25/5 cm H2O, rate 30/min. CC were applied with a rate of 120/min without synchrony to inflations. We observed a significant increase of leak (average increase 11.4%) when CC was added to respiratory support (p = 0.0001). Expired tidal volume was larger in the SIB group than in the two other modes which both applied PEEP. However, tidal volumes caused by CC only were larger in the two groups with PEEP than in the SIB group (without PEEP). There is interaction between lung inflations and CC affecting leak and delivery of tidal volume, which may be influenced by the mode/device used for respiratory support. Leak is larger in the presence of PEEP. However, CC cause additional tidal volume which is larger in the presence of PEEP. © 2016 S. Karger AG, Basel.

  19. Ability of paramedics to perform endotracheal intubation during continuous chest compressions: a randomized cadaver study comparing Pentax AWS and Macintosh laryngoscopes.

    Science.gov (United States)

    Truszewski, Zenon; Czyzewski, Lukasz; Smereka, Jacek; Krajewski, Paweł; Fudalej, Marcin; Madziala, Marcin; Szarpak, Lukasz

    2016-09-01

    The aim of the trial was to compare the time parameters for intubation with the use of the Macintosh (MAC) laryngoscope and Pentax AWS-S100 videolaryngoscope (AWS; Pentax Corporation, Tokyo, Japan) with and without chest compression (CC) by paramedics during simulated cardiopulmonary resuscitation in a cadaver model. This was a randomized crossover cadaver trial. Thirty-five paramedics with no experience in videolaryngoscopy participated in the study. They performed intubation in two emergency scenarios: scenario A, normal airway without CC; scenario B, normal airway with continuous CC. The median time to first ventilation with the use of the AWS and the MAC was similar in scenario A: 25 (IQR, 22-27) seconds vs. 24 (IQR, 22.5-26) seconds (P=.072). A statistically significant difference in TTFV between AWS and MAC was noticed in scenario B (P=.011). In scenario A, the first endotracheal intubation (ETI) attempt success rate was achieved in 97.1% with AWS compared with 94.3% with MAC (P=.43). In scenario B, the success rate after the first ETI attempt with the use of the different intubation methods varied and amounted to 88.6% vs. 77.1% for AWS and MAC, respectively (P=.002). The Pentax AWS offered a superior glottic view as compared with the MAC laryngoscope, which was associated with a higher intubation rate and a shorter intubation time during an uninterrupted CC scenario. However, in the scenario without CC, the results for AWS and MAC were comparable. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. A Comparison of Macintosh and Airtraq Laryngoscopes for Endotracheal Intubation in Adult Patients With Cervical Spine Immobilization Using Manual In Line Axial Stabilization: A Prospective Randomized Study.

    Science.gov (United States)

    Vijayakumar, Vinodhadevi; Rao, Shwethapriya; Shetty, Nanda

    2016-10-01

    During cervical spine immobilization using Manual In Line Axial Stabilization (MILS), it is difficult to visualize the larynx by aligning the oropharyngeolaryngeal axes using Macintosh laryngoscope. Theoretically, Airtraq an anatomically shaped blade with endotracheal tube guide channel offers advantage over Macintosh. We hypothesized that intubation would be easier and faster with Airtraq compared with Macintosh laryngoscope. Ninety anesthetized adult patients with normal airways were intubated by experienced anesthesiologists after cervical immobilization with MILS either with Macintosh or Airtraq. Primary outcomes compared were successful intubation, and degree of difficulty of intubation as assessed by Intubation Difficulty Scale (IDS) score. Secondary outcomes compared were duration of laryngoscopy and intubation, degree of difficulty of intubation as assessed by Numerical Rating Scale score, soft tissue, and dental trauma. All 90 patients were successfully intubated in the first attempt. Intubation as assessed by IDS score was easier in Airtraq (84.44%) in contrast to slight difficulty in the Macintosh (77.78%) group; Numerical Rating Scale score was easy in both the groups (Airtraq-91.12%; Macintosh-93.34%). The median (interquartile range [IQR]) time for laryngoscopy, (12 s [IQR, 8 to 17.5) vs. 8 s [IQR, 6 to 12]); total duration for intubation (25 s [IQR, 20-33] vs. 22 s [IQR, 18-27.5]) were prolonged in Airtraq group in comparison to Macintosh group. In anesthetized adult patients with MILS compared with Macintosh, Airtraq provides equal success rate of intubation, statistically significant (although clinically insignificant) longer duration for laryngoscopy and intubation. Intubation with Airtraq was significantly easier than Macintosh as assessed by the IDS score.

  1. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants—the impact of ventilator settings on tracheal pressure swings

    International Nuclear Information System (INIS)

    Hentschel, Roland; Buntzel, Julia; Guttmann, Josef; Schumann, Stefan

    2011-01-01

    Resistive properties of endotracheal tubes (ETTs) are particularly relevant in newborns and small infants who are generally ventilated through ETTs with a small inner diameter. The ventilation rate is also high and the inspiratory time (ti) is short. These conditions effectuate high airway flows with excessive flow acceleration, so airway resistance and inertance play an important role. We carried out a model study to investigate the impact of varying ETT size, lung compliance and ventilator settings, such as peak inspiratory pressure (PIP), positive end expiratory pressure (PEEP) and inspiratory time (ti) on the pressure–flow characteristics with respect to the resistive and inertive properties of the ETT. Pressure at the Y piece was compared to direct measurement of intratracheal pressure (P trach ) at the tip of the ETT, and pressure drop (ΔP ETT ) was calculated. Applying published tube coefficients (Rohrer's constants and inertance), P trach was calculated from ventilator readings and compared to measured P trach using the root-mean-square error. The most relevant for ΔP ETT was the ETT size, followed by (in descending order) PIP, compliance, ti and PEEP, with gas flow velocity being the principle in common for all these parameters. Depending on the ventilator settings ΔP ETT exceeded 8 mbar in the smallest 2.0 mm ETT. Consideration of inertance as an additional effect in this setting yielded a better agreement of calculated versus measured P trach than Rohrer's constants alone. We speculate that exact tracheal pressure tracings calculated from ventilator readings by applying Rohrer's equation and the inertance determination to small size ETTs would be helpful. As an integral part of ventilator software this would (1) allow an estimate of work of breathing and implementation of an automatic tube compensation, and (2) be important for gentle ventilation in respiratory care, especially of small infants, since it enables the physician to

  2. Does Pre-hospital Endotracheal Intubation Improve Survival in Adults with Non-traumatic Out-of-hospital Cardiac Arrest? A Systematic Review

    Directory of Open Access Journals (Sweden)

    Ling Tiah

    2014-11-01

    Full Text Available Introduction: Endotracheal intubation (ETI is currently considered superior to supraglottic airway devices (SGA for survival and other outcomes among adults with non-traumatic out-of-hospital cardiac arrest (OHCA. We aimed to determine if the research supports this conclusion by conducting a systematic review. Methods: We searched the MEDLINE, Scopus and CINAHL databases for studies published between January 1, 1980, and 30 April 30, 2013, which compared pre-hospital use of ETI with SGA for outcomes of return of spontaneous circulation (ROSC; survival to hospital admission; survival to hospital discharge; and favorable neurological or functional status. We selected studies using pre-specified criteria. Included studies were independently screened for quality using the Newcastle-Ottawa scale. We did not pool results because of study variability. Study outcomes were extracted and results presented as summed odds ratios with 95% CI. Results: We identified five eligible studies: one quasi-randomized controlled trial and four cohort studies, involving 303,348 patients in total. Only three of the five studies reported a higher proportion of ROSC with ETI versus SGA with no difference reported in the remaining two. None found significant differences between ETI and SGA for survival to hospital admission or discharge. One study reported better functional status at discharge for ETI versus SGA. Two studies reported no significant difference for favorable neurological status between ETI and SGA. Conclusion: Current evidence does not conclusively support the superiority of ETI over SGA for multiple outcomes among adults with OHCA. [West J Emerg Med. 2014;15(7:-0.

  3. Intravenous lignocain 2 percent (plain) efficacy in attenuation of stress response to laryngoscopy and endotracheal intubation with impact on in-hospital morbidity and mortality

    International Nuclear Information System (INIS)

    Ahmed, M.S.; Qureshi, M.N.; Uddin, S.S.; Hussain, R.M.

    2016-01-01

    Objective: To evaluate the efficacy of plain lignocain in attenuation of stress response to laryngoscopy and endotracheal intubation with impact on in-hospital mortality or morbidity. Study Design: A randomized control trial. Place and Duration of Study: Our study was carried out from December 2013-14, at tertiary-care hospital. Material and Methods: Patients (n=100 total) were randomized, using non-probability convenient sampling, dividing the population in two groups. Group A (n=50) as control, and in group B (n=50) Injection lignocain plain 2 percent at the rate 1.5 mg/kg was used 3 minutes prior to intubation. Both the groups were observed for changes in hemodynamic parameters i.e. heart rate (HR) systolic and diastolic blood pressure, Mean Arterial Pressure for every minute after baseline (0) and for 5 consecutive minutes (1, 2, 3, 4, and 5). Deviation of >20 percent from baseline was considered significant. The mortality (death within hospital, irrespective of cause) and morbidity (defined as emergence of 4 condition as hypertensive encephalopathy, Acute Coronary Syndrome, Lab proven Myocardial Infarction and negative pulmonary edema) within 10 days of hospitalization were noted. Results: Statistically significant (p-value extremely significant at confidence interval of 98 degrees) results were obtained in the effect of study drug; however, 10 days of hospitalization remained inconclusive for emerging morbidity categories strictly due to the intubation reflexes. We consider few technicalities in peri-operative management resulted in such events. Conclusion: Lignocain is effective in blunting the pressor response towards laryngoscopy and intubation. However the impact on mortality/ morbidity for four conditions remained inconclusive. (author)

  4. Comparison of the Laryngeal Mask Airway (CTrachTM and Direct Coupled Interface-Video Laryngoscope for Endotracheal Intubation: a Prospective, Randomized, Clinical Study

    Directory of Open Access Journals (Sweden)

    Kamil Toker

    2012-09-01

    Full Text Available Objective: Video laryngoscopy was developed to facilitate tracheal intubation of difficult airways. We aimed to compare the efficacy of CTrach™ (CT and Direct Coupled Interface-Videolaryngoscope (DCI-VL in patients with normal airways. Material and Methods: Sixty ASA I–II (American Society of Anesthesiologists adult patients admitted for elective surgery were enrolled in this prospective study. The patients were randomly assigned to two groups, where intubation was performed via CT or DCI-VL. Time to obtain a good glottic view, total intubation time, success rates and the number of patients who required maneuvers for a good glottic view were recorded.Results: The mean time to obtaining a good glottic view was significantly longer with CT than with DCI-VL (29.4±20.3 seconds vs. 12.8±1.9 seconds, respectively; p=0.01. Intubation was achieved on the first attempt in 28 patients in the CT group (93.3% and in 24 in the DCI-VL group (80% (p=0.77. The total intubation time for CT was significantly longer compared to DCI-VL (99.9±36.0 seconds vs. 39.2±21.4 seconds, respectively; p=0.01. Optimization maneuvers were required in eight and two patients in the CT and DCI-VL groups, respectively (p=0.03.Conclusion: Although the normal airway endotracheal intubation success rates were similar in both groups, the time to obtain a good glottic view and the total intubation time were significantly shorter with DCI-VL.

  5. Molecular geometries and relative stabilities of titanium oxide and gold-titanium oxide clusters

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, Rohan J.; Falcinella, Alexander; Metha, Gregory F., E-mail: greg.metha@adelaide.edu.au

    2016-09-30

    Titanium oxide and gold-titanium oxide clusters of stoichiometry M{sub x}O{sub y} (M{sub x} = Ti{sub 3}, Ti{sub 4} & AuTi{sub 3}; y = 0 − (2x + 2)) have been investigated using density functional theory. Geometries of determined global energy minimum structures are reported and other isomers predicted up to 0.5 eV higher in energy. The Ti{sub 3}O{sub n} geometries build upon a triangular Ti{sub 3} motif, while Ti{sub 4}O{sub n} stoichiometries template upon a pseudo-tetrahedral Ti{sub 4} structure. Addition of a gold atom to the Ti{sub 3}O{sub n} series does not significantly alter the cluster geometry, with the gold atom preferentially binding to titanium atoms over oxygen atoms. Adiabatic ionization energies, electron affinities and HOMO/LUMO energies increase in magnitude with increasing oxygenation. The HOMO-LUMO energy gaps reach the bulk anatase band gap energy at stoichiometry (Au)Ti{sub m}O{sub 2m−1}, and increase above this upon further oxygen addition. The most stable structural moieties are found to be a cage-like, C{sub 3v} symmetric Ti{sub 4}O{sub 6/7} geometry and a Ti{sub 3}O{sub 6} structure with an η{sup 3}-bound oxygen atom.

  6. Formation and characterization of titanium nitride and titanium carbide films prepared by reactive sputtering

    International Nuclear Information System (INIS)

    Sundgren, J.-E.

    1982-01-01

    Titanium has been reactively r.f. sputtered in mixed Ar-N 2 and Ar-CH 4 discharges on to substrates held at 775 K. The films obtained have been characterized by scanning electron microscopy, X-ray diffraction and by measurements of hardness and electrical resistivity. The compositions of the films have been determined using Auger electron spectroscopy. The processes occurring both on substrates and target surfaces have been studied and it is shown that the latter is of great importance for the composition and structure of deposited films. Titanium nitride films of full density and with electrical resistivity and hardness values close to those of bulk TiN were only obtained in a narrow range close to the stoichiometric composition. Titanium carbide films grown on non-biased substrates were found to have an open structure and thus a low density. A bias applied to the substrate, however, improved the quality of the films. It is also shown that the heat of formation of the compounds plays an important role in the formation of carbides and nitrides. A large value promotes the development of large grains and dense structures. (Auth.)

  7. Characterization for rbs of Titanium Oxide thin films grown by Dip Coating in a coloidal suspension of nano structured Titanium Oxide

    International Nuclear Information System (INIS)

    Pedrero, E.; Vigil, E.; Zumeta, I.

    1999-01-01

    The depth of Titanium Oxide thin films grown by Dip Coating in a coloidal suspension of nano structured Titanium Oxide was characterized using Rutherford Backscattering Spectrometry. Film depths are compared in function of bath and suspension parameters

  8. Storage characteristics of hydrogen by titanium

    International Nuclear Information System (INIS)

    Lee, S. H.; Kang, H. S.; Back, S. W.; Choi, H. J.; Kim, K. R.; An, D. H.; Lee, H. S.; Jung, H. S.

    2000-01-01

    Hydrogen absorption experiments were performed by the sponge, strip and rod types of titanium(Ti) for investigating the absorption characteristics of hydrogen. From experimental results, Ti sponge showed the high hydrogen absorption capacity inspite of low reaction temperature(25 .deg. C), the H/M, which mean the capacity of hydrogen absorption was measured 2.0 for Ti sponge at 25 .deg. C. However, in case of strip and rod type of Ti, the hydrogen absorption capacities were very low in the experimental condition of 25 .deg. C. The pulverizing phenomena after metal hydriding reaction was observed in both Ti strip and Ti rod. However, the pulverizing phenomena was not observed in the Ti sponges because of high surface area

  9. Cesium titanium silicate and method of making

    Science.gov (United States)

    Balmer, Mari L.

    1997-01-01

    The invention is the new material, a ternary compound of cesium, silica, and titania, together with a method of making the ternary compound, cesium titanium silicate pollucite. More specifically, the invention is Cs.sub.2 Ti.sub.2 Si.sub.4 O.sub.13 pollucite which is a new crystalline phase representing a novel class of Ti-containing zeolites. Compositions contain relatively high Cs.sub.2 O and TiO.sub.2 loadings and are durable glass and ceramic materials. The amount of TiO.sub.2 and Cs.sub.2 that can be incorporated into these glasses and crystalline ceramics far exceeds the limits set for the borosilicate high level waste glass.

  10. Production of titanium carbide from ilmenite

    Directory of Open Access Journals (Sweden)

    Sutham Niyomwas

    2008-03-01

    Full Text Available The production of titanium carbide (TiC powders from ilmenite ore (FeTiO3 powder by means of carbothermal reduction synthesis coupled with hydrochloric acid (HCl leaching process was investigated. A mixture of FeTiO3 and carbon powders was reacted at 1500oC for 1 hr under flowing argon gas. Subsequently, synthesized product of Fe-TiC powders were leached by 10% HCl solutions for 24 hrs to get final product of TiC powders. The powders were characterized using X-ray diffraction, scanning electron and transmission electron microscopy. The product particles were agglomerated in the stage after the leaching process, and the size of this agglomerate was 12.8 μm with a crystallite size of 28.8 nm..

  11. Shape memory effect for titanium nickelide semiproducts

    International Nuclear Information System (INIS)

    Chernov, D.B.; Fatkullina, L.P.; Smirnova, Z.I.; Timonin, G.D.; Olejnikova, S.V.

    1978-01-01

    The thermomechanical properties of titanium nickelide semi-finished products obtained by garnissage melting followed by arc remelting have been studied for the purpose of investigating the NiTi ''form memory'' mechanism. The ingots were subjected to stepped pressing to produce rods. Calcined rods were tension tested. Investigation of the elastic and thermomechanical free return after deformation has shown that the share of elastic return increases as the preliminary deformation degree is increased. The return to the original form began at about 150 deg C; at 200 deg C the process rate decreases and at 300 deg C it stops. The degree of form recovery decreases with the increase of preliminary deformation. The return stress versus preliminary deformation degree relationship has a maximum at 11% strain degree. Maximum thermomechanical return stresses are observed at about 300 deg C. It is noted that yield strength decreases with the increasing degree of deformation to which the semi-finished products are subjected

  12. Cleaning graphene with a titanium sacrificial layer

    International Nuclear Information System (INIS)

    Joiner, C. A.; Roy, T.; Hesabi, Z. R.; Vogel, E. M.; Chakrabarti, B.

    2014-01-01

    Graphene is a promising material for future electronic applications and chemical vapor deposition of graphene on copper is a promising method for synthesizing graphene on the wafer scale. The processing of such graphene films into electronic devices introduces a variety of contaminants which can be difficult to remove. An approach to cleaning residues from the graphene channel is presented in which a thin layer of titanium is deposited via thermal e-beam evaporation and immediately removed. This procedure does not damage the graphene as evidenced by Raman spectroscopy, greatly enhances the electrical performance of the fabricated graphene field effect transistors, and completely removes the chemical residues from the surface of the graphene channel as evidenced by x-ray photoelectron spectroscopy.

  13. Hydrous titanium oxide-supported catalysts

    International Nuclear Information System (INIS)

    Dosch, R.G.; Stohl, F.V.; Richardson, J.T.

    1990-01-01

    Catalysts were prepared on hydrous titanium oxide (HTO) supports by ion exchange of an active metal for Na + ions incorporated in the HTO support during preparation by reaction with the parent Ti alkoxide. Strong active metal-HTO interactions as a result of the ion exchange reaction can require significantly different conditions for activation as compared to catalysts prepared by more widely used incipient wetness methods. The latter catalysts typically involve conversion or while the HTO catalysts require the alteration of electrostatic bonds between the metal and support with subsequent alteration of the support itself. In this paper, the authors discuss the activation, via sulfidation or reduction, of catalysts consisting of Co, Mo, or Ni-Mo dispersed on HTO supports by ion exchange. Correlations between the activation process and the hydrogenation, hydrodeoxygenation, and hydrodesulfurization activities of the catalysts are presented

  14. Surface modification of titanium by plasma nitriding

    Directory of Open Access Journals (Sweden)

    Kapczinski Myriam Pereira

    2003-01-01

    Full Text Available A systematic investigation was undertaken on commercially pure titanium submitted to plasma nitriding. Thirteen different sets of operational parameters (nitriding time, sample temperature and plasma atmosphere were used. Surface analyses were performed using X-ray diffraction, nuclear reaction and scanning electron microscopy. Wear tests were done with stainless steel Gracey scaler, sonic apparatus and pin-on-disc machine. The obtained results indicate that the tribological performance can be improved for samples treated with the following conditions: nitriding time of 3 h; plasma atmosphere consisting of 80%N2+20%H2 or 20%N2+80%H2; sample temperature during nitriding of 600 or 800 degreesC.

  15. Ordering effects in nonstoichiometric titanium carbide

    International Nuclear Information System (INIS)

    Lipatnikov, V.N.; Zueva, L.V.; Gusev, A.I.; Kottar, A.

    2000-01-01

    The effect of nonstoichiometry and ordering on crystalline structure and specific electric resistance (ρ) of TiC y (0.52≤y≤0.98) is studied within the temperature range of 300-1100 K. It is shown that the titanium carbide ordering in the areas 0.52≤y≤0.55, 0.56≤y≤0.58 and 0.62≤y≤0.68 leads to formation of the Ti 2 C cubic and trigonal ordered phase and the Ti 3 C 2 rhombic ordered phase correspondingly. Availability of hysteresis on the ρ(T) dependences in the area of the disorder-order reversible equilibrium transition points out to the fact that the TiC y ↔Ti 2 C and TiC y ↔Ti 3 C 2 transformations are the first order phase transitions [ru

  16. Machinability of cast commercial titanium alloys.

    Science.gov (United States)

    Watanabe, I; Kiyosue, S; Ohkubo, C; Aoki, T; Okabe, T

    2002-01-01

    This study investigated the machinability of cast orthopedic titanium (metastable beta) alloys for possible application to dentistry and compared the results with those of cast CP Ti, Ti-6Al-4V, and Ti-6Al-7Nb, which are currently used in dentistry. Machinability was determined as the amount of metal removed with the use of an electric handpiece and a SiC abrasive wheel turning at four different rotational wheel speeds. The ratios of the amount of metal removed and the wheel volume loss (machining ratio) were also evaluated. Based on these two criteria, the two alpha + beta alloys tested generally exhibited better results for most of the wheel speeds compared to all the other metals tested. The machinability of the three beta alloys employed was similar or worse, depending on the speed of the wheel, compared to CP Ti. Copyright 2002 Wiley Periodicals, Inc.

  17. Swelling in neutron-irradiated titanium alloys

    International Nuclear Information System (INIS)

    Peterson, D.T.

    1982-04-01

    Immersion density measurements have been performed on a series of titanium alloys irradiated in EBR-II to a fluence of 5 x 10 22 n/cm 2 (E > 0.1 MeV) at 450 and 550 0 C. The materials irradiated were the near-alpha alloys Ti-6242S and Ti-5621S, the alpha-beta alloy Ti-64, and the beta alloy Ti-38644. Swelling was observed in all alloys with the greater swelling being observed at 550 0 C. Microstructural examination revealed the presence of voids in all alloys. Ti-38644 was found to be the most radiation resistant. Ti-6242S and Ti-5621S also displayed good radiation resistance, whereas considerable swelling and precipitation were observed in Ti-64 at 550 0 C

  18. Microstructural characterization of silicon added titanium aluminide

    International Nuclear Information System (INIS)

    Khan, A.N.

    2009-01-01

    Titanium aluminides intermetallic compounds have received great attention during the past decade, since they have the potential, in aircraft and automotive engines, to replace the high density Ni-base superalloys However, these intermetallics possess poor oxidation properties at high temperatures. Previous studies showed that protective alumina scale formation on gamma-TiAl can be obtained by small additions (around 2 at.%) of Ag. In the present study, a number of cast Ti-Al-Si alloys were investigated in relation to transient oxide formation in air at 1300 deg. C. After various oxidation times the oxide composition, microstructure and morphology were studied by combining a number of analysis techniques. The TiAl-Si alloys appear to form Al Ti and Si oxides. However, the formation of silicon oxide at the interface of base metal and scale slows down the oxidation rate significantly. (author)

  19. Preparation and integration of nanostructured titanium dioxide

    KAUST Repository

    Zeng, Hua Chun

    2011-10-01

    Titanium dioxide (TiO2) is a chemically stable nontoxic transition-metal oxide associated with a wide range of existing chemical engineering processes. In this short review, recent research endeavors in preparation and integration of nanostructured TiO2 materials system will be featured and discussed for their potential new applications. Because material development always plays pivotal roles in the progress of a particular engineering discipline, the reviewed subjects will provide useful information to stimulate nanoscale research of chemical engineering, linking established fundamentals with practical applications. Some critical issues and challenges regarding further development of this important functional material for nanotechnology will also be addressed. © 2011 Elsevier Ltd. All rights reserved.

  20. Bacterial adherence to anodized titanium alloy

    International Nuclear Information System (INIS)

    Peremarch, C Perez-Jorge; Tanoira, R Perez; Arenas, M A; Matykina, E; Conde, A; De Damborenea, J J; Gomez Barrena, E; Esteban, J

    2010-01-01

    The aim of this study was to evaluate Staphylococcus sp adhesion to modified surfaces of anodized titanium alloy (Ti-6Al-4V). Surface modification involved generation of fluoride-containing titanium oxide nanotube films. Specimens of Ti-6Al-4V alloy 6-4 ELI-grade 23- meets the requirements of ASTM F136 2002A (AMS 2631B class A1) were anodized in a mixture of sulphuric/hydrofluoric acid at 20 V for 5 and 60 min to form a 100 nm-thick porous film of 20 nm pore diameter and 230 nm-thick nanotube films of 100 nm in diameter. The amount of fluorine in the oxide films was of 6% and of 4%, respectively. Collection strains and six clinical strains each of Staphylococcus aureus and Staphylococcus epidermidis were studied. The adherence study was performed using a previously published protocol by Kinnari et al. The experiments were performed in triplicates. As a result, lower adherence was detected for collection strains in modified materials than in unmodified controls. Differences between clinical strains were detected for both species (p<0.0001, Kruskal-Wallis test), although global data showed similar results to that of collection strains (p<0.0001, Kruskal-Wallis test). Adherence of bacteria to modified surfaces was decreased for both species. The results also reflect a difference in the adherence between S. aureus and S. epidermidis to the modified material. As a conclusion, not only we were able to confirm the decrease of adherence in the modified surface, but also the need to test multiple clinical strains to obtain more realistic microbiological results due to intraspecies differences.

  1. Plasma electrolytic oxidation of Titanium Aluminides

    International Nuclear Information System (INIS)

    Morgenstern, R; Sieber, M; Lampke, T; Grund, T; Wielage, B

    2016-01-01

    Due to their outstanding specific mechanical and high-temperature properties, titanium aluminides exhibit a high potential for lightweight components exposed to high temperatures. However, their application is limited through their low wear resistance and the increasing high-temperature oxidation starting from about 750 °C. By the use of oxide ceramic coatings, these constraints can be set aside and the possible applications of titanium aluminides can be extended. The plasma electrolytic oxidation (PEO) represents a process for the generation of oxide ceramic conversion coatings with high thickness. The current work aims at the clarification of different electrolyte components’ influences on the oxide layer evolution on alloy TNM-B1 (Ti43.5Al4Nb1Mo0.1B) and the creation of compact and wear resistant coatings. Model experiments were applied using a ramp-wise increase of the anodic potential in order to show the influence of electrolyte components on the discharge initiation and the early stage of the oxide layer growth. The production of PEO layers with technically relevant thicknesses close to 100 μm was conducted in alkaline electrolytes with varying amounts of Na 2 SiO 3 ·5H 2 O and K 4 P 2 O 7 under symmetrically pulsed current conditions. Coating properties were evaluated with regard to morphology, chemical composition, hardness and wear resistance. The addition of phosphates and silicates leads to an increasing substrate passivation and the growth of compact oxide layers with higher thicknesses. Optimal electrolyte compositions for maximum coating hardness and thickness were identified by statistical analysis. Under these conditions, a homogeneous inner layer with low porosity can be achieved. The frictional wear behavior of the compact coating layer is superior to a hard anodized layer on aluminum. (paper)

  2. Electrochemical capacitance performance of titanium nitride nanoarray

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Yibing, E-mail: ybxie@seu.edu.cn [School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189 (China); Suzhou Research Institute of Southeast University, Suzhou 215123 (China); Wang, Yong [School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189 (China); Du, Hongxiu [School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189 (China); Suzhou Research Institute of Southeast University, Suzhou 215123 (China)

    2013-12-01

    Highlights: • TiN nanoarray is formed by a nitridation process of TiO{sub 2} in ammonia atmosphere. • TiN nanoarray exhibits much higher EDLC capacitance than TiO{sub 2} nanoarray. • The specific capacitance of TiN nanoarray achieves a high level of 99.7 mF cm{sup −2}. • A flexible solid-state supercapacitor is constructed by TiN nanoarray and PVA gel. -- Abstract: In this study, titanium nitride (TiN) nanoarrays with a short nanotube and long nanopore structure have been prepared by an anodization process of ultra thin titanium foil in ethylene glycol (EG) solution containing ammonium fluoride, subsequent calcination process in an air atmosphere, and final nitridation process in an ammonia atmosphere. The morphology and microstructure characterization has been conducted using field emission scanning electron microscope and X-ray diffraction. The electrochemical properties have been investigated through cyclic voltammetry and electrochemical impedance spectrum measurements. The electrochemical capacitance performance has been investigated by galvanostatic charge–discharge measurements in the acidic, neural and alkali electrolyte solution. Well-defined TiN nanoarrays contribute a much higher capacitance performance than titania (TiO{sub 2}) in the supercapacitor application due to the extraordinarily improved electrical conductivity. Such an electrochemical capacitance can be further enhanced by increasing aspect ratio of TiN nanoarray from short nanotubes to long nanopores. A flexible supercapacitor has been constructed using two symmetrical TiN nanoarray electrodes and a polyvinyl alcohol (PVA) gel electrolyte with H{sub 2}SO{sub 4}–KCl–H{sub 2}O–EG. Such a supercapacitor has a highly improved potential window and still keeps good electrochemical energy storage. TiN nanoarray with a high aspect ratio can act well as an ultra thin film electrode material of flexible supercapacitor to contribute a superior capacitance performance.

  3. Comparison of the effect of lignocaine instilled through the endotracheal tube and intravenous lignocaine on the extubation response in patients undergoing craniotomy with skull pins: A randomized double blind clinical trial

    Directory of Open Access Journals (Sweden)

    Smitha Elizabeth George

    2013-01-01

    Full Text Available Background: A desirable combination of smooth extubation and an awake patient after neurosurgical procedures is difficult to achieve in patients with skull pins. Lignocaine instilled into endotracheal tube has been reported to suppress cough by a local mucosal anesthetizing effect. We aimed to evaluate if this effect will last till extubation, if given before pin removal. Materials and Methods: A total of 114 patients undergoing elective craniotomy were divided into three groups and were given 1 mg/kg of intravenous (IV, 2% lignocaine (Group 1, placebo (Group 2 and 1 mg/kg of 2% lignocaine sprayed down the endotracheal tube (Group 3 before skull pin removal. The effectiveness of each to blunt extubation response was compared. Plasma levels of lignocaine were measured 10 min after administration of the study drug and at extubation. Sedation scores were noted, immediately after extubation and 10 min later. Results: Two percent of lignocaine instilled through endotracheal route was not superior to the IV route or placebo in attenuating cough or hemodynamic response at extubation when given 20-30 min before extubation. The plasma levels of lignocaine (0.8 μg/ml were not high enough even at the end of 10 min to have a suppressive effect on cough if given IV or intratracheally (IT. Lignocaine did not delay awakening in these groups. Conclusion: IT lignocaine in the dose of 1 mg/kg does not prevent cough at extubation if given 20-30 min before extubation. If the action is by a local mucosal anesthetizing effect, it does not last for 20-30 min to cover the period from pin removal to extubation.

  4. Calcium phosphate-based coatings on titanium and its alloys.

    Science.gov (United States)

    Narayanan, R; Seshadri, S K; Kwon, T Y; Kim, K H

    2008-04-01

    Use of titanium as biomaterial is possible because of its very favorable biocompatibility with living tissue. Titanium implants having calcium phosphate coatings on their surface show good fixation to the bone. This review covers briefly the requirements of typical biomaterials and narrowly focuses on the works on titanium. Calcium phosphate ceramics for use in implants are introduced and various methods of producing calcium phosphate coating on titanium substrates are elaborated. Advantages and disadvantages of each type of coating from the view point of process simplicity, cost-effectiveness, stability of the coatings, coating integration with the bone, cell behavior, and so forth are highlighted. Taking into account all these factors, the efficient method(s) of producing these coatings are indicated finally.

  5. Titanium Loop Heat Pipes for Space Nuclear Radiators, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will develop titanium Loop Heat Pipes (LHPs) that can be used in low-mass space nuclear radiators, such as...

  6. Hollow Mill for Extraction of Stripped Titanium Screws: An Easy ...

    African Journals Online (AJOL)

    countries. The known alternative in such condition is ... Key words: Hollow mill, stripped screws, titanium locked plates ... used a locally manufactured stainless steel hollow mill, ... head ‑ plate hole” assembly as a mono‑block single unit. In.

  7. Predictions of titanium alloy properties using thermodynamic modeling tools

    Science.gov (United States)

    Zhang, F.; Xie, F.-Y.; Chen, S.-L.; Chang, Y. A.; Furrer, D.; Venkatesh, V.

    2005-12-01

    Thermodynamic modeling tools have become essential in understanding the effect of alloy chemistry on the final microstructure of a material. Implementation of such tools to improve titanium processing via parameter optimization has resulted in significant cost savings through the elimination of shop/laboratory trials and tests. In this study, a thermodynamic modeling tool developed at CompuTherm, LLC, is being used to predict β transus, phase proportions, phase chemistries, partitioning coefficients, and phase boundaries of multicomponent titanium alloys. This modeling tool includes Pandat, software for multicomponent phase equilibrium calculations, and PanTitanium, a thermodynamic database for titanium alloys. Model predictions are compared with experimental results for one α-β alloy (Ti-64) and two near-β alloys (Ti-17 and Ti-10-2-3). The alloying elements, especially the interstitial elements O, N, H, and C, have been shown to have a significant effect on the β transus temperature, and are discussed in more detail herein.

  8. Comparison of porosity measurement techniques for porous titanium scaffolds evaluation

    International Nuclear Information System (INIS)

    Oliveira, M.V.; Ribeiro, A.A.; Moreira, A.C.; Moraes, A.M.C.; Appoloni, C.R.; Pereira, L.C.

    2009-01-01

    Porous titanium has been used for grafts and implant coatings as it allows the mechanical interlocking of the pores and bone. Evaluation of porous scaffolds for bone regeneration is essential for their manufacture. Porosity, pore size, pore shape and pore homogeneity are parameters that influence strongly the mechanical strength and biological functionality. In this study, porous titanium samples were manufactured by powder metallurgy by using pure titanium powders mixed with a pore former. The quantification of the porosity parameters was assessed in this work by geometric method and gamma-ray transmission, the non-destructive techniques and metallographic images processing, a destructive technique. Qualitative evaluation of pore morphology and surface topography were performed by scanning electron microscopy and optical microscopy. The results obtained and the effectiveness of the techniques used were compared in order to select those most suitable for characterization of porous titanium scaffolds. (author)

  9. Lunar-derived titanium alloys for hydrogen storage

    Science.gov (United States)

    Love, S.; Hertzberg, A.; Woodcock, G.

    1992-01-01

    Hydrogen gas, which plays an important role in many projected lunar power systems and industrial processes, can be stored in metallic titanium and in certain titanium alloys as an interstitial hydride compound. Storing and retrieving hydrogen with titanium-iron alloy requires substantially less energy investment than storage by liquefaction. Metal hydride storage systems can be designed to operate at a wide range of temperatures and pressures. A few such systems have been developed for terrestrial applications. A drawback of metal hydride storage for lunar applications is the system's large mass per mole of hydrogen stored, which rules out transporting it from earth. The transportation problem can be solved by using native lunar materials, which are rich in titanium and iron.

  10. Compatibility of niobium, titanium, and vanadium metals with LMFBR cladding

    International Nuclear Information System (INIS)

    Wilson, C.N.

    1975-10-01

    A series of laboratory capsule annealing experiments were conducted to assess the compatibility of niobium, vanadium, and titanium with 316 stainless steel cladding in the temperature range of 700 to 800 0 C. Niobium, vanadium, and titanium are cantidate oxygen absorber materials for control of oxygen chemistry in LMFBR fuel pins. Capsule examination indicated good compatibility between niobium and 316 stainless steel at 800 0 C. Potential compatibility problems between cladding and vanadium or titanium were indicated at 800 0 C under reducing conditions. In the presence of Pu/sub 0.25/U/sub 0.75/O/sub 1.98/ fuel (Δanti G 02 congruent to -160 kcal/mole) no reaction was observed between vanadium or titanium and cladding at 800 0 C

  11. An Insoluble Titanium-Lead Anode for Sulfate Electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Ferdman, Alla

    2005-05-11

    The project is devoted to the development of novel insoluble anodes for copper electrowinning and electrolytic manganese dioxide (EMD) production. The anodes are made of titanium-lead composite material produced by techniques of powder metallurgy, compaction of titanium powder, sintering and subsequent lead infiltration. The titanium-lead anode combines beneficial electrochemical behavior of a lead anode with high mechanical properties and corrosion resistance of a titanium anode. In the titanium-lead anode, the titanium stabilizes the lead, preventing it from spalling, and the lead sheathes the titanium, protecting it from passivation. Interconnections between manufacturing process, structure, composition and properties of the titanium-lead composite material were investigated. The material containing 20-30 vol.% of lead had optimal combination of mechanical and electrochemical properties. Optimal process parameters to manufacture the anodes were identified. Prototypes having optimized composition and structure were produced for testing in operating conditions of copper electrowinning and EMD production. Bench-scale, mini-pilot scale and pilot scale tests were performed. The test anodes were of both a plate design and a flow-through cylindrical design. The cylindrical anodes were composed of cylinders containing titanium inner rods and fitting over titanium-lead bushings. The cylindrical design allows the electrolyte to flow through the anode, which enhances diffusion of the electrolyte reactants. The cylindrical anodes demonstrate higher mass transport capabilities and increased electrical efficiency compared to the plate anodes. Copper electrowinning represents the primary target market for the titanium-lead anode. A full-size cylindrical anode performance in copper electrowinning conditions was monitored over a year. The test anode to cathode voltage was stable in the 1.8 to 2.0 volt range. Copper cathode morphology was very smooth and uniform. There was no

  12. Mechanical strength and stiffness of biodegradable and titanium osteofixation systems

    NARCIS (Netherlands)

    Buijs, Gerrit J.; van der Houwen, Eduard B.; Bos, Rudulf R. M.; Verkerke, Gijsbertus J.

    Purpose: To present relevant mechanical data to simplify the selection of an osteofixation system for situations requiring immobilization in oral and maxillofacial surgery. Materials and Methods: Seven biodegradable and 2 titanium osteofixation systems were investigated. The plates and screws were

  13. Grain growth in ultrafine titanium powders during sintering

    International Nuclear Information System (INIS)

    Panigrahi, B.B.; Godkhindi, M.M.

    2006-01-01

    Grain growth behaviour of fine (∼3 μm) and attrition milled nanocrystalline (∼32 nm) titanium powers during sintering have been studied. The activation energies of grain growth (Q g ) in fine titanium were found to be 192.9 and 142.4 kJ/mol at lower and higher temperature ranges, respectively. The nanocrystalline titanium showed very low values of Q g (54.6 kJ/mol) at lower temperatures and it increased to 273.2 kJ/mol at higher temperatures. The constant (n) in nano Ti system was found to have unusually very high values of 6.5-8.2. The grain boundary rotation along with the diffusional processes could be the grain growth mechanism in nanocrystalline and in fine titanium powders

  14. Development and Characterization of Titanium Compound N anostructures

    Science.gov (United States)

    Zhou, Zhou

    The development and characterization of titanium compound nanostructures have been achieved, for potential applications in energy industry. Oil and gas, one of the traditional industry fields, observes accumulating demands on active implementations of nanotechnology, for the numerous advantages that nanomaterials can introduce to both product performances and field operations. By using chemical vapor deposition and liquid exfoliation, various titanium compound nanostructures have been synthesized through this project. Attractively, these two material fabrication methods have been recognized to be industrial friendly in terms of cost efficiency and productivity. The development of nanostructures, aiming at oil and gas field applications, presents novel solutions for existing issues, such as low durability of drilling tools, high friction in mechanical operations and ineffective heat dissipation. Titanium compound nanostructures, including titanium borides, nitrides and sulfides are therefore investigated for such applications as protective coating, lubrication and thermal management.

  15. Green oxidations: Titanium dioxide induced tandem oxidation coupling reactions

    OpenAIRE

    Jeena, Vineet; Robinson, Ross S

    2009-01-01

    Summary The application of titanium dioxide as an oxidant in tandem oxidation type processes is described. Under microwave irradiation, quinoxalines have been synthesized in good yields from the corresponding ?-hydroxyketones.

  16. One half of a prototype titanium vacuum chamber

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    Designed and constructed in the ISR Department, it could be for general use at intersection regions. The use of titanium instead of stainless steel increases the "transparency" to particles by a factor of about two for the same wall thickness.

  17. Contact Stress Design Parameters for Titanium Bearings, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Air-Lock's Phase I effort tested the effects of ball induced contact stresses on Titanium bearing races. The contact stress design limit that would achieve a...

  18. Titanium Nanosurface Modification by Anodization for Orthopedic Applications

    National Research Council Canada - National Science Library

    Yao, Chang; Slamovich, Elliott B; Webster, Thomas J

    2005-01-01

    .... For this reason, the objective of the present in vitro study was to modify the surface of conventional titanium to include nanostructured surface features that promote the functions of osteoblasts (bone-forming cells...

  19. Synthesis and characterization of nano silicon and titanium nitride ...

    Indian Academy of Sciences (India)

    The characterization techniques indicated ... Scalable synthesis; microwave plasma; chemical synthesis; nanoparticles. 1. Introduction ... used but very few methods are available to produce silicon and titanium ... current (A). (m3/h). 1. Si. 2.1.

  20. Sorption kinetics of cesium on hydrous titanium dioxide

    International Nuclear Information System (INIS)

    Altas, Y.; Tel, H.; Yaprak, G.

    2003-01-01

    Two types of hydrous titanium dioxide possessing different surface properties were prepared and characterized to study the sorption kinetics of cesium. The effect of pH on the adsorption capacity were determined in both type sorbents and the maximum adsorption percentage of cesium were observed at pH 12. To elucidate the kinetics of ion-exchange reaction on hydrous titanium dioxide, the isotopic exchange rates of cesium ions between hydrous titanium dioxides and aqueous solutions were measured radiochemically and compared with each other. The diffusion coefficients of Cs + ion for Type1 and Type2 titanium dioxides at pH 12 were calculated as 2.79 x 10 -11 m 2 s -1 and 1.52 x 10 -11 m 2 s -1 , respectively, under particle diffusion controlled conditions. (orig.)

  1. Titanium dioxide nanoparticles cause genotoxicity in human lung epithelial cells

    Science.gov (United States)

    The use of engineered nanoparticles in consumer products is steadily increasing. However, the health effects of exposure to these nanoparticles are not thoroughly understood. This study investigated the genotoxicity of six titanium dioxide and two cerium oxide nanoparticles of va...

  2. Laser Cladding of TiC for Better Titanium Components

    OpenAIRE

    Sampedro, Jesús; Pérez, I; CÁRCEL GONZÁLEZ, BERNABÉ; Ramos, José Antonio; Amigó Borrás, Vicente

    2011-01-01

    Pure commercial titanium is widely used because of its high corrosion resistance and lower cost compared with other titanium alloys, in particular when there is no high wear requirements. Nevertheless, the wear resistance is poor and surface damage usually occurs in areas under contact loadings. Laser cladding is a suitable technique for manufacturing precise and defect free coatings of a dissimilar material with higher wear and corrosion resistance. In this work a good understanding of laser...

  3. LASER SURFACE MODIFICATION OF TITANIUM ALLOYS — A REVIEW

    OpenAIRE

    Y. S. TIAN; C. Z. CHEN; D. Y. WANG; T. Q. LEI

    2005-01-01

    Recent developments of laser surface modification of titanium alloys for increasing their corrosion, wear and oxidation resistance are introduced. The effects of laser processing parameters on the resulting surface properties of titanium alloys are reviewed. The problems to be solved and the prospects in the field of laser modification of Ti alloys are discussed. Due to the intrinsic properties, a laser beam can be focused onto the metallic surface to produce a broad range of treatments depen...

  4. Study of aging and ordering processes in titanium carbide

    International Nuclear Information System (INIS)

    Arbuzov, M.P.; Khaenko, B.V.; Kachkovskaya, Eh.T.

    1977-01-01

    Aging and ordering processes in titanium carbide were investigated on monocrystals (fragments of alloys) with the aid of roentgenographic method. The sequence of phase transformations during aging was ascertained,and a monoclinic structure of the carbon atoms ordering is suggested. The microhardness of titanium carbide was studied as a function of the heat treatment of alloys and the main factors (ordering and dislocation structure) which govern the difference in the microhardness of hardened and aged (annealed) specimens were determined

  5. Candida albicans biofilm on titanium: effect of peroxidase precoating

    Directory of Open Access Journals (Sweden)

    Mohamed Ahariz

    2010-08-01

    Full Text Available Mohamed Ahariz1, Philippe Courtois1,21Laboratory of Experimental Hormonology, Université Libre de Bruxelles, Brussels, 2UER de Biologie Médicale, Haute Ecole Francisco Ferrer, Brussels, BelgiumAbstract: The present study aimed to document Candida albicans biofilm development on titanium and its modulation by a peroxidase-precoated material which can generate antimicrobials, such as hypoiodite or hypothiocyanite, from hydrogen peroxide, iodide, or thiocyanate. For this purpose, titanium (powder or foil was suspended in Sabouraud liquid medium inoculated with C. albicans ATCC10231. After continuous stirring for 2–21 days at room temperature, the supernatant was monitored by turbidimetry at 600 nm and titanium washed three times in sterile Sabouraud broth. Using the tetrazolium salt MTT-formazan assay, the titanium-adherent fungal biomass was measured as 7.50 ± 0.60 × 106 blastoconidia per gram of titanium powder (n = 30 and 0.50 ± 0.04 × 106 blastoconidia per cm² of titanium foil (n = 12. The presence of yeast on the surface of titanium was confirmed by microscopy both on fresh preparations and after calcofluor white staining. However, in the presence of peroxidase systems (lactoperoxidase with substrates such as hydrogen peroxide donor, iodide, or thiocyanate, Candida growth in both planktonic and attached phases appeared to be inhibited. Moreover, this study demonstrates the possible partition of peroxidase systems between titanium material (peroxidase-precoated and liquid environment (containing peroxidase substrates to limit C. albicans biofilm formation.Keywords: adhesion, material, oral, yeast

  6. Trial manufacturing of titanium-carbon steel composite overpack

    International Nuclear Information System (INIS)

    Honma, Nobuyuki; Chiba, Takahiko; Tanai, Kenji

    1999-11-01

    This paper reports the results of design analysis and trial manufacturing of full-scale titanium-carbon steel composite overpacks. The overpack is one of the key components of the engineered barrier system, hence, it is necessary to confirm the applicability of current technique in their manufacture. The required thickness was calculated according to mechanical resistance analysis, based on models used in current nuclear facilities. The Adequacy of the calculated dimensions was confirmed by finite-element methods. To investigate the necessity of a radiation shielding function of the overpack, the irradiation from vitrified waste has been calculated. As a result, it was shown that shielding on handling and transport equipment is a more reasonable and practical approach than to increase thickness of overpack to attain a self-shielding capability. After the above investigation, trial manufacturing of full-scale model of titanium-carbon steel composite overpack has been carried out. For corrosion-resistant material, ASTM Grade-2 titanium was selected. The titanium layer was bonded individually to a cylindrical shell and fiat cover plates (top and bottom) made of carbon steel. For the cylindrical shell portion, a cylindrically formed titanium layer was fitted to the inner carbon steel vessel by shrinkage. For the flat cover plates (top and bottom), titanium plate material was coated by explosive bonding. Electron beam welding and gas metal arc welding were combined to weld of the cover plates to the body. No significant failure was evident from inspections of the fabrication process, and the applicability of current technology for manufacturing titanium-carbon steel composite overpack was confirmed. Future research and development items regarding titanium-carbon steel composite overpacks are also discussed. (author)

  7. Laser beam welding of titanium additive manufactured parts

    OpenAIRE

    Wits, Wessel Willems; Jauregui Becker, Juan Manuel

    2015-01-01

    In this paper the joinability of titanium Additive Manufactured (AM) parts is explored. Keyhole welding, using a pulsed laser beam, of conventionally produced parts is compared to AM parts. Metal AM parts are notorious for having remaining porosities and other non-isotropic properties due to the layered manufacturing process. This study shows that due to these deficiencies more energy per unit weld length is required to obtain a similar keyhole geometry for titanium AM parts. It is also demon...

  8. Tribological investigations of perfluoroalkylsilanes monolayers deposited on titanium surface

    International Nuclear Information System (INIS)

    Cichomski, Michał

    2012-01-01

    Therefore the present work reports a systematic study of titanium modification by fluoroalkylsilanes and surface characterization from the tribological point of view. The vapor phase deposition method was used to modify titanium surfaces by fluoroalkylsilanes and the influence of the used modifier on the tribological properties is presented. The modification procedure efficiency, surface structure and morphology were characterized by secondary ion mass spectrometry, infrared spectroscopy and atomic force microscopy. The effectiveness of modification of the titanium surface was monitored by the measurement of the wetting contact angle and the surface free energy. The increase of surface hydrophobicity was observed upon the modification by increasing the wetting contact angle and reducing the surface free energy. The tribological performance of various perfluoroalkylsilanes films on the titanium surface was investigated in mili- and nano-newton load ranges. Dependence of the adhesive force and coefficient of friction values obtained in nano- and micro-scale on fluoroalkyl chain length was observed. Nano- and micro-tribological measurements show that titanium modified by fluoroalkylsilanes has lower adhesion and coefficient of friction than unmodified one. The investigation also indicates a decrease of the friction coefficient with increasing fluoric alkyl chain length. It was found that the titanium modified by fluoroalkylsilanes with longer alkyl chains is a prime candidate for practical use as a lubricant in biomedical and electronic applications. -- Highlights: ► Titanium surface modification by perfluoroalkylsilanes was investigated. ► The effectiveness of modification was monitored by the surface free energy. ► The modification procedure correctness was characterized by ToF-SIMS, AFM, FT-IR measurements. ► The tribological performance of modified titanium in differed scale was studied.

  9. Corrosion stability of cermets on the base of titanium nitride

    International Nuclear Information System (INIS)

    Kajdash, O.N.; Marinich, M.A.; Kuzenkova, M.A.; Manzheleev, I.V.

    1991-01-01

    Corrosion resistance of titanium nitride and its cermets in 5% of HCl, 7% of HNO 3 , 10% of H 2 SO 4 is studied. It is established that alloys TiN-Ni-Mo alloyed with chromium (from 10 to 15%) possess the highest corrosion resistance. Cermet TiN-Cr has the higher stability than titanium nitride due to formation of binary nitride (Ti, Cr)N

  10. Enhanced ultrasonically assisted turning of a β-titanium alloy.

    Science.gov (United States)

    Maurotto, Agostino; Muhammad, Riaz; Roy, Anish; Silberschmidt, Vadim V

    2013-09-01

    Although titanium alloys have outstanding mechanical properties such as high hot hardness, a good strength-to-weight ratio and high corrosion resistance; their low thermal conductivity, high chemical affinity to tool materials severely impair their machinability. Ultrasonically assisted machining (UAM) is an advanced machining technique, which has been shown to improve machinability of a β-titanium alloy, namely, Ti-15-3-3-3, when compared to conventional turning processes. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Ultrasonic Surface Treatment of Titanium Alloys. The Submicrocrystalline State

    Science.gov (United States)

    Klimenov, V. A.; Vlasov, V. A.; Borozna, V. Y.; Klopotov, A. A.

    2015-09-01

    The paper presents the results of the research on improvement of physical-and- mechanical properties of titanium alloys VT1-0 and VT6 by modification of surfaces using ultrasonic treatment, and a comprehensive study of the microstructure and mechanical properties of modified surface layers. It has been established that exposure to ultrasonic treatment leads to formation in the surface layer of a structure with an average size of elements 50 - 100 nm, depending on the brand of titanium alloy.

  12. Laser colouring on titanium alloys: characterisation and potential applications

    OpenAIRE

    Franceschini, Federica; Demir, Ali Gökhan; Dowding, Colin; Previtali, Barbara; Griffiths, Jonathan David

    2014-01-01

    Oxides of titanium exhibit vivid colours that can be generated naturally or manipulated through controlled oxidation processes. The application of a laser beam for colouring titanium permits flexible manipulation of the oxidized geometry with high spatial resolution. The laser-based procedure can be applied in an ambient atmosphere to generate long-lasting coloured marks. Today, these properties are largely exploited in artistic applications such as jewellery, eyewear frames, watch components...

  13. Correlation of lattice distortion with photocatalytic activity of titanium dioxide

    International Nuclear Information System (INIS)

    Wang Xia; Shui Miao; Li Rongsheng; Song Yue

    2008-01-01

    The photocatalytic activity of titanium dioxide dispersions on X-3B pigment degradation has been investigated. A variety of factors that would influence the photocatalytic activity such as crystallite size, lattice distortion, and anatase content are discussed in detail. It is found that lattice distortion is the most important one among these factors and is expected to inhibit the hole and electron pair recombination. It determines, to some extent, the photocatalytic efficiency of titanium dioxide dispersions

  14. Titanium zirconium and hafnium coordination compounds with vanillin thiosemicarbazone

    International Nuclear Information System (INIS)

    Konunova, Ts.B.; Kudritskaya, S.A.

    1987-01-01

    Coordination compounds of titanium zirconium and hafnium tetrachlorides with vanillin thiosemicarbazone of MCl 4 x nLig composition, where n=1.5, 4 for titanium and 1, 2, 4 for zirconium and hafnium, are synthesized. Molar conductivity of ethanol solutions is measured; IR spectroscopic and thermochemical investigation are carried out. The supposition about ligand coordination via sulfur and azomethine nitrogen atoms is made. In all cases hafnium forms stable compounds than zirconium

  15. Hydroxyapatite electrodeposition on anodized titanium nanotubes for orthopedic applications

    Energy Technology Data Exchange (ETDEWEB)

    Parcharoen, Yardnapar [Department of Biological Engineering, Faculty of Engineering, King Mongkut' s University of Technology Thonburi, Bangkok (Thailand); Kajitvichyanukul, Puangrat [Center of Excellence on Environmental Research and Innovation, Faculty of Engineering, Naresuan University, Phitsanulok (Thailand); Sirivisoot, Sirinrath [Department of Biological Engineering, Faculty of Engineering, King Mongkut' s University of Technology Thonburi, Bangkok (Thailand); Termsuksawad, Preecha, E-mail: preecha.ter@kmutt.ac.th [Division of Materials Technology, School of Energy, Environment and Materials, King Mongkut' s University of Technology Thonburi, 126 Pracha Uthit Rd., Bang Mod, ThungKhru, Bangkok 10140 (Thailand)

    2014-08-30

    Highlights: • We found that different anodization time of titanium significantly effects on nanotube length which further impacts adhesion strength of hydroxyapatite coating layers. • Adhesion strength of Hydroxyapatite (HA) coated on titanium dioxide nanotubes is better than that of HA coated on titanium plate. • Hydroxyapatite coated on titanium dioxide nanotubes showed higher cell density and better spreading of MC3T3-E1 cells (bone-forming cells) than that coated on titanium plate surface. - Abstract: Nanotubes modification for orthopedic implants has shown interesting biological performances (such as improving cell adhesion, cell differentiation, and enhancing osseointegration). The purpose of this study is to investigate effect of titanium dioxide (TiO{sub 2}) nanotube feature on performance of hydroxyapatite-coated titanium (Ti) bone implants. TiO{sub 2} nanotubes were prepared by anodization using ammonium fluoride electrolyte (NH{sub 4}F) with and without modifiers (PEG400 and Glycerol) at various potential forms, and times. After anodization, the nanotubes were subsequently annealed. TiO{sub 2} nanotubes were characterized by scanning electron microscope and X-ray diffractometer. The amorphous to anatase transformation due to annealing was observed. Smooth and highly organized TiO{sub 2} nanotubes were found when high viscous electrolyte, NH{sub 4}F in glycerol, was used. Negative voltage (−4 V) during anodization was confirmed to increase nanotube thickness. Length of the TiO{sub 2} nanotubes was significantly increased by times. The TiO{sub 2} nanotube was electrodeposited with hydroxyapatite (HA) and its adhesion was estimated by adhesive tape test. The result showed that nanotubes with the tube length of 560 nm showed excellent adhesion. The coated HA were tested for biological test by live/dead cell straining. HA coated on TiO{sub 2} nanotubes showed higher cells density, higher live cells, and more spreading of MC3T3-E1 cells than that

  16. Electrodeposition of niobium and titanium in molten salts

    International Nuclear Information System (INIS)

    Sartori, A.F.; Chagas, H.C.

    1988-01-01

    The electrodeposition of niobium and titanium in molten fluorides from the additions of fluorine niobates and fluorine titanates of potassium is described in laboratory and pilot scale. The temperature influence, the current density and the time deposition over the current efficiency, the deposits structure and the deposits purity are studied. The conditions for niobium coating over copper and carbon steel and for titanium coating over carbon steel are also presented. (C.G.C.) [pt

  17. Mechanism of cesium sorption on potassium titanium hexacyanoferrate

    International Nuclear Information System (INIS)

    Sun Yongxia; Xu Shiping; Song Chongli

    1998-01-01

    The mechanism of cesium sorption on potassium titanium hexacyanoferrate is described. The dependence of the sorption speed on temperature, particle granule size, and the stirring speed is studied. The results show that the sorption process is controlled by liquid film diffusion and particle diffusion. An exchange reaction occurs mainly between K + in the exchanger and Cs + in the solution, i.e. potassium titanium hexacyanoferrate, and Cs + of simulated high-level liquid waste

  18. Swelling behavior of titanium-modified AISI 316 alloys

    International Nuclear Information System (INIS)

    Garner, F.A.; Brager, H.R.; Puigh, R.J.

    1984-01-01

    It appears that titanium additions to stainless steels covering a wide compositional range around the specifications of AISI 316 result only in an increased delay period before neutron-induced void swelling proceeds. Once swelling is initiated the post transient behavior of both annealed and cold-worked titanium-modified steels is quite consistent with that of AISI 316, approaching a relatively temperature-independent swelling rate of approx. 1% per dpa

  19. Nanoscale Bonding between Human Bone and Titanium Surfaces: Osseohybridization

    Directory of Open Access Journals (Sweden)

    Jun-Sik Kim

    2015-01-01

    Full Text Available Until now, the chemical bonding between titanium and bone has been examined only through a few mechanical detachment tests. Therefore, in this study, a sandblasted and acid-etched titanium mini-implant was removed from a human patient after 2 months of placement in order to identify the chemical integration mechanism for nanoscale osseointegration of titanium implants. To prepare a transmission electron microscopy (TEM specimen, the natural state was preserved as much as possible by cryofixation and scanning electron microscope/focused ion beam (SEM-FIB milling without any chemical treatment. High-resolution TEM (HRTEM, energy dispersive X-ray spectroscopy (EDS, and scanning TEM (STEM/electron energy loss spectroscopic analysis (EELS were used to investigate the chemical composition and structure at the interface between the titanium and bone tissue. HRTEM and EDS data showed evidence of crystalline hydroxyapatite and intermixing of bone with the oxide layer of the implant. The STEM/EELS experiment provided particularly interesting results: carbon existed in polysaccharides, calcium and phosphorus existed as tricalcium phosphate (TCP, and titanium existed as oxidized titanium. In addition, the oxygen energy loss near edge structures (ELNESs showed a possibility of the presence of CaTiO3. These STEM/EELS results can be explained by structures either with or without a chemical reaction layer. The possible existence of the osseohybridization area and the form of the carbon suggest that reconsideration of the standard definition of osseointegration is necessary.

  20. Titanium diffusion in shinbone of rats with osseointegrated implants.

    Science.gov (United States)

    Grenón, Miriam S; Robledo, José; Ibáñez, Juan Carlos; Sánchez, Héctor J

    2016-11-01

    Dental implants are composed of commercially pure Ti (which is actually an alloy of titanium, and minor or trace components such as aluminium and vanadium). When the implant is inserted, its surface undergoes a number of chemical and mechanical processes, releasing particles of titanium to the medium. The metabolism of free ions of titanium is uncertain; the uptaking processes in the body are not well known, nor their toxic dose. In addition, physical properties of newly formed bone, such as diffusivity and activation energy, are scarce and rarely studied. In this study, we analysed the diffusion of titanium in the titanium-implanted shinbones of six adult male Wistar rats by spatially resolved micro x-ray fluorescence. The measurements were carried out at the microfluorescence station of the x-ray fluorescence (XRF) beamline of the Brazilian synchrotron facility LNLS (from Portuguese 'Laboratorio Nacional de Luz Sincrotron'). For each sample, XRF spectra were taken by linear scanning in area near the new bone formed around the Ti implant. The scanning line shows a clear effect of titanium diffusion whereas calcium intensity presents a different behaviour. Moreover, a clear correlation among the different structures of bones is observed in the Ti and Ca intensities. The results obtained in these measurements may allow determining quantitatively the parameters of diffusion rates and other physical properties of new bone like diffusion coefficients. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.